Bayesian Meta-Analysis of Cronbach's Coefficient Alpha to Evaluate Informative Hypotheses
ERIC Educational Resources Information Center
Okada, Kensuke
2015-01-01
This paper proposes a new method to evaluate informative hypotheses for meta-analysis of Cronbach's coefficient alpha using a Bayesian approach. The coefficient alpha is one of the most widely used reliability indices. In meta-analyses of reliability, researchers typically form specific informative hypotheses beforehand, such as "alpha of…
On the Use, the Misuse, and the Very Limited Usefulness of Cronbach's Alpha
ERIC Educational Resources Information Center
Sijtsma, Klaas
2009-01-01
This discussion paper argues that both the use of Cronbach's alpha as a reliability estimate and as a measure of internal consistency suffer from major problems. First, alpha always has a value, which cannot be equal to the test score's reliability given the inter-item covariance matrix and the usual assumptions about measurement error. Second, in…
ERIC Educational Resources Information Center
Zinbarg, Richard E.; Revelle, William; Yovel, Iftah; Li, Wen
2005-01-01
We make theoretical comparisons among five coefficients--Cronbach's [alpha], Revelle's [beta], McDonald's [omega][sub h], and two alternative conceptualizations of reliability. Though many end users and psychometricians alike may not distinguish among these five coefficients, we demonstrate formally their nonequivalence. Specifically, whereas…
ERIC Educational Resources Information Center
Liu, Yan; Zumbo, Bruno D.
2007-01-01
The impact of outliers on Cronbach's coefficient [alpha] has not been documented in the psychometric or statistical literature. This is an important gap because coefficient [alpha] is the most widely used measurement statistic in all of the social, educational, and health sciences. The impact of outliers on coefficient [alpha] is investigated for…
Understanding a Widely Misunderstood Statistic: Cronbach's "Alpha"
ERIC Educational Resources Information Center
Ritter, Nicola L.
2010-01-01
It is important to explore score reliability in virtually all studies, because tests are not reliable. The present paper explains the most frequently used reliability estimate, coefficient alpha, so that the coefficient's conceptual underpinnings will be understood. Researchers need to understand score reliability because of the possible impact…
The Use of Cronbach's Alpha When Developing and Reporting Research Instruments in Science Education
NASA Astrophysics Data System (ADS)
Taber, Keith S.
2017-06-01
Cronbach's alpha is a statistic commonly quoted by authors to demonstrate that tests and scales that have been constructed or adopted for research projects are fit for purpose. Cronbach's alpha is regularly adopted in studies in science education: it was referred to in 69 different papers published in 4 leading science education journals in a single year (2015)—usually as a measure of reliability. This article explores how this statistic is used in reporting science education research and what it represents. Authors often cite alpha values with little commentary to explain why they feel this statistic is relevant and seldom interpret the result for readers beyond citing an arbitrary threshold for an acceptable value. Those authors who do offer readers qualitative descriptors interpreting alpha values adopt a diverse and seemingly arbitrary terminology. More seriously, illustrative examples from the science education literature demonstrate that alpha may be acceptable even when there are recognised problems with the scales concerned. Alpha is also sometimes inappropriately used to claim an instrument is unidimensional. It is argued that a high value of alpha offers limited evidence of the reliability of a research instrument, and that indeed a very high value may actually be undesirable when developing a test of scientific knowledge or understanding. Guidance is offered to authors reporting, and readers evaluating, studies that present Cronbach's alpha statistic as evidence of instrument quality.
We need more replication research - A case for test-retest reliability.
Leppink, Jimmie; Pérez-Fuster, Patricia
2017-06-01
Following debates in psychology on the importance of replication research, we have also started to see pleas for a more prominent role for replication research in medical education. To enable replication research, it is of paramount importance to carefully study the reliability of the instruments we use. Cronbach's alpha has been the most widely used estimator of reliability in the field of medical education, notably as some kind of quality label of test or questionnaire scores based on multiple items or of the reliability of assessment across exam stations. However, as this narrative review outlines, Cronbach's alpha or alternative reliability statistics may complement but not replace psychometric methods such as factor analysis. Moreover, multiple-item measurements should be preferred above single-item measurements, and when using single-item measurements, coefficients as Cronbach's alpha should not be interpreted as indicators of the reliability of a single item when that item is administered after fundamentally different activities, such as learning tasks that differ in content. Finally, if we want to follow up on recent pleas for more replication research, we have to start studying the test-retest reliability of the instruments we use.
Sun, Wei; Chou, Chih-Ping; Stacy, Alan W; Ma, Huiyan; Unger, Jennifer; Gallaher, Peggy
2007-02-01
Cronbach's a is widely used in social science research to estimate the internal consistency of reliability of a measurement scale. However, when items are not strictly parallel, the Cronbach's a coefficient provides a lower-bound estimate of true reliability, and this estimate may be further biased downward when items are dichotomous. The estimation of standardized Cronbach's a for a scale with dichotomous items can be improved by using the upper bound of coefficient phi. SAS and SPSS macros have been developed in this article to obtain standardized Cronbach's a via this method. The simulation analysis showed that Cronbach's a from upper-bound phi might be appropriate for estimating the real reliability when standardized Cronbach's a is problematic.
ERIC Educational Resources Information Center
Kistner, Emily O.; Muller, Keith E.
2004-01-01
Intraclass correlation and Cronbach's alpha are widely used to describe reliability of tests and measurements. Even with Gaussian data, exact distributions are known only for compound symmetric covariance (equal variances and equal correlations). Recently, large sample Gaussian approximations were derived for the distribution functions. New exact…
Reliability of the Children's Attitudes Toward the Environment Scale.
Kim, Sang-Min; Zeman, Catherine; Kostareva, Olga
2007-08-01
The Children's Attitudes toward the Environment Scale, developed by Musser and Malkus (1994), gave Cronbach alpha .73 and .83 at pretest and 3-wk. later for 274 children and a test-retest r of only .47. While Cronbach alpha was similar to the value reported by the test developers, it is close to the low end of acceptability.
Psychometric Evaluation of the Wang Pregnancy Stress Scale: Revised for Taiwanese Women.
Wang, Janet F; Billings, Anthony A
2015-01-01
Develop and assess psychometric properties of the Wang Pregnancy Stress Scale for measuring stress among pregnant women in Taiwan. Data were collected in 3 obstetric and gynecological clinics in Taiwan; 485 pregnant women participated in this study. We used exploratory factor analysis and internal consistency reliability was measured using Cronbach's alpha. A 4-factor structure emerged for the Wang Pregnancy Stress Scale. The internal reliability of the scale as measured by Cronbach's alpha was .898, with standardized alpha .905. The Wang Pregnancy Stress Scale has high reliability and validity in measuring pregnancy stress that would allow nurses or health care workers to measure women's stress levels during pregnancy. Nurses can use the assessed pregnancy stress to alter intervention of care for their pregnant clients.
A Test Reliability Analysis of an Abbreviated Version of the Pupil Control Ideology Form.
ERIC Educational Resources Information Center
Gaffney, Patrick V.
A reliability analysis was conducted of an abbreviated, 10-item version of the Pupil Control Ideology Form (PCI), using the Cronbach's alpha technique (L. J. Cronbach, 1951) and the computation of the standard error of measurement. The PCI measures a teacher's orientation toward pupil control. Subjects were 168 preservice teachers from one private…
Good practices in normal childbirth: reliability analysis of an instrument by Cronbach's Alpha.
Gottems, Leila Bernarda Donato; Carvalho, Elisabete Mesquita Peres De; Guilhem, Dirce; Pires, Maria Raquel Gomes Maia
2018-01-01
to analyze the internal consistency of the evaluation instrument of the adherence to the good practices of childbirth and birth care in the professionals, through Cronbach's Alpha Coefficient for each of the dimensions and for the total instrument. this is a descriptive and cross-sectional study performed in obstetric centers of eleven public hospitals in the Federal District, with a questionnaire applied to 261 professionals who worked in the delivery care. The study was attended by 261 professionals, 42.5% (111) nurses and 57.5% (150) physicians. The reliability evaluation of the instrument by the Cronbach Alfa resulted in 0.53, 0.78 and 0.76 for dimensions 1, 2 and 3, after debugging that resulted in the exclusion of 11 items. the instrument obtained Cronbach's alpha of 0.80. There is a need for improvement in the items of dimension 1 that refer to attitudes, knowledge, and practices of the organization of the network of care to gestation, childbirth, and birth. However, it can be applied in the way it is used to evaluate practices based on scientific evidence of childbirth care.
Schmidt, Frank L; Le, Huy; Ilies, Remus
2003-06-01
On the basis of an empirical study of measures of constructs from the cognitive domain, the personality domain, and the domain of affective traits, the authors of this study examine the implications of transient measurement error for the measurement of frequently studied individual differences variables. The authors clarify relevant reliability concepts as they relate to transient error and present a procedure for estimating the coefficient of equivalence and stability (L. J. Cronbach, 1947), the only classical reliability coefficient that assesses all 3 major sources of measurement error (random response, transient, and specific factor errors). The authors conclude that transient error exists in all 3 trait domains and is especially large in the domain of affective traits. Their findings indicate that the nearly universal use of the coefficient of equivalence (Cronbach's alpha; L. J. Cronbach, 1951), which fails to assess transient error, leads to overestimates of reliability and undercorrections for biases due to measurement error.
Validity and cross-cultural adaptation of the persian version of the oxford elbow score.
Ebrahimzadeh, Mohammad H; Kachooei, Amir Reza; Vahedi, Ehsan; Moradi, Ali; Mashayekhi, Zeinab; Hallaj-Moghaddam, Mohammad; Azami, Mehran; Birjandinejad, Ali
2014-01-01
Oxford Elbow Score (OES) is a patient-reported questionnaire used to assess outcomes after elbow surgery. The aim of this study was to validate and adapt the OES into Persian language. After forward-backward translation of the OES into Persian, a total number of 92 patients after elbow surgeries completed the Persian OES along with the Persian DASH and SF-36. To assess test-retest reliability, 31 randomly selected patients (34%) completed the Persian OES again after three days while abstaining from all forms of therapeutic regimens. Reliability of the Persian OES was assessed by measuring intraclass correlation coefficient (ICC) for test-retest reliability and Cronbach's alpha for internal consistency. Spearman's correlation coefficient was used to test the construct validity. Cronbach's alpha coefficient was 0.92 showing excellent reliability. Cronbach's alpha for function, pain, and social-psychological subscales was 0.95, 0.86, and 0.85, respectively. Intraclass correlation coefficient (ICC) was 0.85 for the overall questionnaire and 0.90, 0.76, and 0.75 for function, pain, and social-psychological subscales, respectively. Construct validity was confirmed as the Spearman correlation between OES and DASH was 0.80. Persian OES is a valid and reliable patient-reported outcome measure to assess postsurgical elbow status in Persian speaking population.
Component Structure, Reliability, and Stability of Lawrence's Self-Esteem Questionnaire (LAWSEQ)
ERIC Educational Resources Information Center
Rae, Gordon; Dalto, Georgia; Loughrey, Dolores; Woods, Caroline
2011-01-01
Lawrence's Self-Esteem Questionnaire (LAWSEQ) was administered to 120 Year 1 pupils in six schools in Belfast, Northern Ireland. A principal components analysis indicated that the scale items were unidimensional and that the reliability of the scores, as estimated by Cronbach's alpha, was satisfactory ([alpha] = 0.73). There were no differences…
Pereira, Fernanda Maria Vieira; Lam, Simon Ching; Gir, Elucir
2017-01-01
ABSTRACT Objective: this study aimed to carry of the cultural adaptation and to evaluate the reliability of the Compliance with Standard Precautions Scale (CSPS) for nurses in Brazil. Method: the adaptation process entailed translation, consensus among judges, back-translation, semantic validation and pretest. The reliability was evaluated by internal consistency (Cronbach alpha) and stability (test-retest). The instrument was administered to a sample group of 300 nurses who worked in a large hospital located in the city of São Paulo/SP, Brazil. Results: through the semantic validation, the items from the scale were considered understandable and deemed important for the nurse´s clinical practice. The CSPS Brazilian Portuguese version (CSPS-PB) revealed excellent interpretability. The Cronbach`s alpha was 0.61 and the intraclass correlation coefficient was 0.85. Conclusion: the initial study showed that CSPS-PB is appropriate to assess compliance with standard precautions among nurses in Brazil. The reliability was considered acceptable. Furhter study is necessary to evaluate its comprehensive psychometric properties. PMID:28301030
Hadi, Azlihanis Abdul; Naing, Nyi Nyi; Daud, Aziah; Nordin, Rusli
2006-11-01
This study was conducted to assess the reliability and construct validity of the Malay version of Job Content Questionnaire (JCQ) among secondary school teachers in Kota Bharu, Kelantan. A total of 68 teachers consented to participate in the study and were administered the Malay version of JCQ. Reliability was determined using Cronbach's alpha for internal consistency whilst construct validity was assessed using factor analysis. The results indicated that Cronbach's alpha coefficients revealed decision latitude (0.75), psychological job demand (0.50) and social support (0.84). Factor analysis showed three meaningful common factors that could explain the construct of Karasek's demand-control-social support model. The study suggests the JCQ scales are reliable and valid tools for assessing job stress in school teachers.
Xiao, Yuan-mei; Wang, Zhi-ming; Wang, Mian-zhen; Lan, Ya-jia
2005-06-01
To test the reliability and validity of two mental workload assessment scales, i.e. subjective workload assessment technique (SWAT) and NASA task load index (NASA-TLX). One thousand two hundred and sixty-eight mental workers were sampled from various kinds of occupations, such as scientific research, education, administration and medicine, etc, with randomized cluster sampling. The re-test reliability, split-half reliability, Cronbach's alpha coefficient and correlation coefficients between item score and total score were adopted to test the reliability. The test of validity included structure validity. The re-test reliability coefficients of these two scales and their items were ranged from 0.516 to 0.753 (P < 0.01), indicating the two scales had good re-test reliability; the split-half reliability of SWAT was 0.645, and its Cronbach's alpha coefficient was more than 0.80, all the correlation coefficients between its items score and total score were more than 0.70; as for NASA-TLX, both the split-half reliability and Cronbach's alpha coefficient were more than 0.80, the correlation coefficients between its items score and total score were all more than 0.60 (P < 0.01) except the item of performance. Both scales had good inner consistency. The Pearson correlation coefficient between the two scales was 0.492 (P < 0.01), implying the results of the two scales had good consistency. Factor analysis showed that the two scales had good structure validity. Both SWAT and NASA-TLX have good reliability and validity and may be used as a valid tool to assess mental workload in China after being revised properly.
An Innovative Excel Application to Improve Exam Reliability in Marketing Courses
ERIC Educational Resources Information Center
Keller, Christopher M.; Kros, John F.
2011-01-01
Measures of survey reliability are commonly addressed in marketing courses. One statistic of reliability is "Cronbach's alpha." This paper presents an application of survey reliability as a reflexive application of multiple-choice exam validation. The application provides an interactive decision support system that incorporates survey item…
Development of a Taiwan cancer-related fatigue cognition questionnaire: reliability and validity
Chen, Chien-Hsin; Wu, Szu-Yuan
2017-01-01
Purpose We prospectively designed a Taiwan cancer-related fatigue cognition questionnaire, version 1.0 (TCRFCQ-V1.0), for Taiwanese patients with cancer and investigated the reliability and validity of this questionnaire. Results The completion rate of the TCRFCQ-V1.0 was high (97% of the patients completed all items), and the rate of missing data was low (0.2%–1.1% for each item). Moreover, the Cronbach alpha value was 0.889. We eliminated 5 items because their respective Cronbach alpha values were higher than the total mean value of Cronbach's alpha. Overall, the TCRFCQ-V1.0 had adequate Cronbach alpha coefficients (range, from 0.882 to 0.889). In addition, the results of Bartlett's test were significant (chi-squared, 2390.11; p < 0.001), indicating the appropriateness of factor analysis. Sampling adequacy was confirmed by the Kaiser–Meyer–Olkin statistic of 0.868. Through exploratory factor analysis, we identified 6 factors with eigenvalues of > 1, and the scree plot indicated no flattening factors. Overall, 28 items achieved a factor loading of ≥ 0.55. Materials and Methods We enrolled patients with cancer who were aged > 18 years, had received a pathological diagnosis of cancer, and had undergone cancer treatments such as surgery, chemotherapy, radiotherapy, or concurrent chemoradiotherapy at a single institute in Taiwan. Of the identified 167 eligible patients, 161 (96.4%) were approached. Of these patients, 6 (7.2%) declined to participate and 155 (92.8%) were interviewed. The initial 43 items in the TCRFCQ-V1.0 were assessed for ceiling and floor effects. Conclusions The TCRFCQ-V1.0 is a reliable and valid instrument for measuring CRF cognition in Taiwanese patients with cancer. PMID:28418869
Development of a Taiwan cancer-related fatigue cognition questionnaire: reliability and validity.
Lai, Shih-Chiung; Lin, Wei-Chun; Chen, Chien-Hsin; Wu, Szu-Yuan
2017-04-25
We prospectively designed a Taiwan cancer-related fatigue cognition questionnaire, version 1.0 (TCRFCQ-V1.0), for Taiwanese patients with cancer and investigated the reliability and validity of this questionnaire. The completion rate of the TCRFCQ-V1.0 was high (97% of the patients completed all items), and the rate of missing data was low (0.2%-1.1% for each item). Moreover, the Cronbach alpha value was 0.889. We eliminated 5 items because their respective Cronbach alpha values were higher than the total mean value of Cronbach's alpha. Overall, the TCRFCQ-V1.0 had adequate Cronbach alpha coefficients (range, from 0.882 to 0.889). In addition, the results of Bartlett's test were significant (chi-squared, 2390.11; p < 0.001), indicating the appropriateness of factor analysis. Sampling adequacy was confirmed by the Kaiser-Meyer-Olkin statistic of 0.868. Through exploratory factor analysis, we identified 6 factors with eigenvalues of > 1, and the scree plot indicated no flattening factors. Overall, 28 items achieved a factor loading of ≥ 0.55. We enrolled patients with cancer who were aged > 18 years, had received a pathological diagnosis of cancer, and had undergone cancer treatments such as surgery, chemotherapy, radiotherapy, or concurrent chemoradiotherapy at a single institute in Taiwan. Of the identified 167 eligible patients, 161 (96.4%) were approached. Of these patients, 6 (7.2%) declined to participate and 155 (92.8%) were interviewed. The initial 43 items in the TCRFCQ-V1.0 were assessed for ceiling and floor effects. The TCRFCQ-V1.0 is a reliable and valid instrument for measuring CRF cognition in Taiwanese patients with cancer.
Marcin, James P; Romano, Patrick S; Dharmar, Madan; Chamberlain, James M; Dudley, Nanette; Macias, Charles G; Nigrovic, Lise E; Powell, Elizabeth C; Rogers, Alexander J; Sonnett, Meridith; Tzimenatos, Leah; Alpern, Elizabeth R; Andrews-Dickert, Rebecca; Borgialli, Dominic A; Sidney, Erika; Casper, Charlie; Dean, Jonathan Michael; Kuppermann, Nathan
2018-06-01
To evaluate the consistency, reliability, and validity of an implicit review instrument that measures the quality of care provided to children in the emergency department (ED). Medical records of randomly selected children from 12 EDs in the Pediatric Emergency Care Applied Research Network (PECARN). Eight pediatric emergency medicine physicians applied the instrument to 620 medical records. We determined internal consistency using Cronbach's alpha and inter-rater reliability using the intraclass correlation coefficient (ICC). We evaluated the validity of the instrument by correlating scores with four condition-specific explicit review instruments. Individual reviewers' Cronbach's alpha had a mean of 0.85 with a range of 0.76-0.97; overall Cronbach's alpha was 0.90. The ICC was 0.49 for the summary score with a range from 0.40 to 0.46. Correlations between the quality of care score and the four condition-specific explicit review scores ranged from 0.24 to 0.38. The quality of care instrument demonstrated good internal consistency, moderate inter-rater reliability, high inter-rater agreement, and evidence supporting validity. The instrument could be useful for systems' assessment and research in evaluating the care delivered to children in the ED. © Health Research and Educational Trust.
Validity and reliability of CHOICE Health Experience Questionnaire: Thai version.
Aiyasanon, Nipa; Premasathian, Nalinee; Nimmannit, Akarin; Jetanavanich, Pantip; Sritippayawan, Suchai
2009-09-01
Assess the reliability and validity of the Thai translation of the CHOICE Health Experience Questionnaire (CHEQ), which is the English-language questionnaire, developed specifically for End-stage-renal disease (ESRD) patients. The CHEQ comprised of two parts, nine general domains of SF-36 (physical function, role-physical, bodily pain, mental health, role-emotional, social function, vitality, general health, and report transition) and 16 dialysis specific domains of the CHEQ (role-physical, mental health, general health, freedom, travel restriction, cognitive function, financial function, restriction diet and fluids, recreation, work, body image, symptoms, sex, sleep, access, and quality of life). The authors translated the CHEQ questionnaire into Thai and confirmed the accuracy by back translation. Pilot study sample was 10 Thai ESRD patients. Then the CHEQ (Thai) was applied to 110 Thai ESRD patients. Twenty-three patients had chronic peritoneal dialysis patients and 87 were chronic intermittent hemodialysis patients. Statistical analysis included descriptive statistics, Mann-Whitney U test, Student's t-test, and Cronbach's alpha. Construct validity was satisfactory with the significant difference less than 0.001 between the low and high group. The reliability coefficient for the Cronbach's alpha of the total scale of the CHEQ (Thai) was 0.98. The Cronbach 's alphas were greater than 0.7 for all domains, range from 0.58 to 0.92, except the social function and quality of life domain (alpha = 0.66 and 0.575). The CHEQ (Thai) is reliable and valid for assessment of Thai ESRD patients receiving chronic dialysis. Its properties are similar to those reported in the original version.
Development of the Anxiety Scale for Natural Disaster: Examination of its Reliability
NASA Astrophysics Data System (ADS)
Matsumoto, Miki; Yatabe, Ryuichi
The objective of present study was to develop the a nxiety scale for natural disaster, and to examineits reliability. We developed the 14 items for the anxiety scale based on anticipated damage of Nankai earthquake in Ehime prefecture. The subjects consist of 391 people in Yawatahama city, Ehime prefecture. Firstly, we analyzed the latent factors which influenced the anxiety for natural disaster by using the factor analysis method. Secondly, we cal culated Cronbach's coefficient alpha. The result of the factor analysis confirmed the three factors such as "anxiety for lifeline damage", "anxiety for second ary disaster" and "fear for others". Cronbach's coefficient alpha for each factor showed the high interna l consistency reliability. We considered that each factor could prove to be a valuable tool for researc h about the person's anxiety for natural disaster.
Nakano, Hideki; Kodama, Takayuki; Ukai, Kazumasa; Kawahara, Satoru; Horikawa, Shiori; Murata, Shin
2018-05-02
In this study, we aimed to (1) translate the English version of the Kinesthetic and Visual Imagery Questionnaire (KVIQ), which assesses motor imagery ability, into Japanese, and (2) investigate the reliability and validity of the Japanese KVIQ. We enrolled 28 healthy adults in this study. We used Cronbach’s alpha coefficients to assess reliability reflected by the internal consistency. Additionally, we assessed validity reflected by the criterion-related validity between the Japanese KVIQ and the Japanese version of the Movement Imagery Questionnaire-Revised (MIQ-R) with Spearman’s rank correlation coefficients. The Cronbach’s alpha coefficients for the KVIQ-20 were 0.88 (Visual) and 0.91 (Kinesthetic), which indicates high reliability. There was a significant positive correlation between the Japanese KVIQ-20 (Total) and the Japanese MIQ-R (Total) (r = 0.86, p < 0.01). Our results suggest that the Japanese KVIQ is an assessment that is a reliable and valid index of motor imagery ability.
Aboraya, Ahmed; El-Missiry, Ahmed; Barlowe, Johnna; John, Collin; Ebrahimian, Alireza; Muvvala, Srinivas; Brandish, Ja'me; Mansour, Hader; Zheng, Wanhong; Chumber, Paramjit; Berry, James; Elswick, Daniel; Hill, Cheryl; Swager, Lauren; Abo Elez, Warda; Ashour, Hala; Haikal, Amal; Eissa, Ahmed; Rabie, Menan; El-Missiry, Marwa; El Sheikh, Mona; Hassan, Dina; Ragab, Sherif; Sabry, Mohamed; Hendawy, Heba; Abdel Rahman, Rola; Radwan, Doaa; Sherif, Mohamed; Abou El Asaad, Marwa; Khalil, Sherien; Hashim, Reem; Border, Katherine; Menguito, Roberto; France, Cheryl; Hu, Wei; Shuttleworth, Olivia; Price, Elizabeth
2014-07-01
Existing standardized diagnostic interviews are not used by psychiatrists in clinical settings. There is an urgent need for a clinician-administered tool for assessment of adult psychopathology that produces dimensional measures, in addition to categorical diagnoses. The Standard for Clinicians' Interview in Psychiatry (SCIP) was designed to be used in clinical settings and generates dimensional measures. The reliability of the SCIP was tested at six sites: one hospital and two clinics in USA, two hospitals in Egypt and one clinic in Canada. Participants were adult patients who were admitted for inpatient psychiatric treatment or came for regular office visits in the outpatient clinic. Refusal rate was <1%. Missing data were <1.1%. Patients with dementia, mental retardation or serious medical conditions were excluded. A total of 1,004 subjects were interviewed between 2000 and 2012. Inter-rater reliability (Kappa) was measured for 150 SCIP items: 116 items (77.3%) had good reliability (Kappa>0.7), 28 items (18.7%) had fair reliability (Kappa ranges from 0.5 to 0.7) and six items (4%) had poor reliability (Kappa<0.5). Cronbach's alpha for internal consistency was measured for the SCIP dimensions: anxiety, posttraumatic stress, depression, mania, hallucinations, Schneider first-rank symptoms, delusions, disorganized thoughts, disorganized behavior, negative symptoms, alcohol addiction, drug addiction, attention and hyperactivity. All of the SCIP dimensions had substantial Cronbach's alpha values (>0.7) with the exception of disorganized thoughts (Cronbach's alpha=0.375). The SCIP is a reliable tool for assessing psychological symptoms, signs and dimensions of the main psychiatric diagnoses. Copyright © 2014 Elsevier B.V. All rights reserved.
Development and Validation of the Caring Loneliness Scale.
Karhe, Liisa; Kaunonen, Marja; Koivisto, Anna-Maija
2016-12-01
The Caring Loneliness Scale (CARLOS) includes 5 categories derived from earlier qualitative research. This article assesses the reliability and construct validity of a scale designed to measure patient experiences of loneliness in a professional caring relationship. Statistical analysis with 4 different sample sizes included Cronbach's alpha and exploratory factor analysis with principal axis factoring extraction. The sample size of 250 gave the most useful and comprehensible structure, but all 4 samples yielded underlying content of loneliness experiences. The initial 5 categories were reduced to 4 factors with 24 items and Cronbach's alpha ranging from .77 to .90. The findings support the reliability and validity of CARLOS for the assessment of Finnish breast cancer and heart surgery patients' experiences but as all instruments, further validation is needed.
Gurupur, Varadraj; Shettian, Kruparaj; Xu, Peixin; Hines, Scott; Desselles, Mitzi; Dhawan, Manish; Wan, Thomas Th; Raffenaud, Amanda; Anderson, Lindsey
2017-09-01
This study identified the readiness factors that may create challenges in the use of telemedicine among patients in northern Louisiana with cancer. To identify these readiness factors, the team of investigators developed 19 survey questions that were provided to the patients or to their caregivers. The team collected responses from 147 respondents from rural and urban residential backgrounds. These responses were used to identify the individuals' readiness for utilising telemedicine through factor analysis, Cronbach's alpha reliability test, analysis of variance and ordinary least squares regression. The analysis results indicated that the favourable factor (positive readiness item) had a mean value of 3.47, whereas the unfavourable factor (negative readiness item) had a mean value of 2.76. Cronbach's alpha reliability test provided an alpha value of 0.79. Overall, our study indicated a positive attitude towards the use of telemedicine in northern Louisiana.
Laksmiastuti, Sri Ratna; Budiardjo, Sarworini Bagio; Sutadi, Heriandi
2017-06-01
Predicting caries risk in children can be done by identifying caries risk factors. It is an important measure which contributes to best understanding of the cariogenic profile of the patient. Identification could be done by clinical examination and answering the questionnaire. We arrange the study to verify the questionnaire validation for predicting caries risk in children. The study was conducted on 62 pairs of mothers and their children, aged between 3 and 5 years. The questionnaire consists of 10 questions concerning mothers' attitude and knowledge about oral health. The reliability and validity test is based on Cronbach's alpha and correlation coefficient value. All question are reliable (Cronbach's alpha = 0.873) and valid (Corrected item-total item correlation >0.4). Five questionnaires of mother's attitude about oral health and five questionnaires of mother's knowledge about oral health are reliable and valid for predicting caries risk in children.
Wood, David L; Sawicki, Gregory S; Miller, M David; Smotherman, Carmen; Lukens-Bull, Katryne; Livingood, William C; Ferris, Maria; Kraemer, Dale F
2014-01-01
National consensus statements recommend that providers regularly assess the transition readiness skills of adolescent and young adults (AYA). In 2010 we developed a 29-item version of Transition Readiness Assessment Questionnaire (TRAQ). We reevaluated item performance and factor structure, and reassessed the TRAQ's reliability and validity. We surveyed youth from 3 academic clinics in Jacksonville, Florida; Chapel Hill, North Carolina; and Boston, Massachusetts. Participants were AYA with special health care needs aged 14 to 21 years. From a convenience sample of 306 patients, we conducted item reduction strategies and exploratory factor analysis (EFA). On a second convenience sample of 221 patients, we conducted confirmatory factor analysis (CFA). Internal reliability was assessed by Cronbach's alpha and criterion validity. Analyses were conducted by the Wilcoxon rank sum test and mixed linear models. The item reduction and EFA resulted in a 20-item scale with 5 identified subscales. The CFA conducted on a second sample provided a good fit to the data. The overall scale has high reliability overall (Cronbach's alpha = .94) and good reliability for 4 of the 5 subscales (Cronbach's alpha ranging from .90 to .77 in the pooled sample). Each of the 5 subscale scores were significantly higher for adolescents aged 18 years and older versus those younger than 18 (P < .0001) in both univariate and multivariate analyses. The 20-item, 5-factor structure for the TRAQ is supported by EFA and CFA on independent samples and has good internal reliability and criterion validity. Additional work is needed to expand or revise the TRAQ subscales and test their predictive validity. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
Kistner, Emily O; Muller, Keith E
2004-09-01
Intraclass correlation and Cronbach's alpha are widely used to describe reliability of tests and measurements. Even with Gaussian data, exact distributions are known only for compound symmetric covariance (equal variances and equal correlations). Recently, large sample Gaussian approximations were derived for the distribution functions. New exact results allow calculating the exact distribution function and other properties of intraclass correlation and Cronbach's alpha, for Gaussian data with any covariance pattern, not just compound symmetry. Probabilities are computed in terms of the distribution function of a weighted sum of independent chi-square random variables. New F approximations for the distribution functions of intraclass correlation and Cronbach's alpha are much simpler and faster to compute than the exact forms. Assuming the covariance matrix is known, the approximations typically provide sufficient accuracy, even with as few as ten observations. Either the exact or approximate distributions may be used to create confidence intervals around an estimate of reliability. Monte Carlo simulations led to a number of conclusions. Correctly assuming that the covariance matrix is compound symmetric leads to accurate confidence intervals, as was expected from previously known results. However, assuming and estimating a general covariance matrix produces somewhat optimistically narrow confidence intervals with 10 observations. Increasing sample size to 100 gives essentially unbiased coverage. Incorrectly assuming compound symmetry leads to pessimistically large confidence intervals, with pessimism increasing with sample size. In contrast, incorrectly assuming general covariance introduces only a modest optimistic bias in small samples. Hence the new methods seem preferable for creating confidence intervals, except when compound symmetry definitely holds.
Marr-Lyon, Lisa R; Gupchup, Gireesh V; Anderson, Joe R
2012-01-01
The Purdue Pharmacist Directive Guidance (PPDG) Scale was developed to assess patients' perceptions of the level of pharmacist-provided (1) instruction and (2) feedback and goal-setting-2 aspects of pharmaceutical care. Calculations of its psychometric properties stemming from SPSS and R were similar, but distinct differences were apparent. Using SPSS and R software packages, researchers aimed to examine the construct validity of the PPDG using a higher order factoring procedure; in tandem, McDonald's omega and Cronbach's alpha were calculated as means of reliability analyses. Ninety-nine patients with either type I or type II diabetes, aged 18 years or older, able to read and write English, and who could provide written-informed consent participated in the study. Data were collected in 8 community pharmacies in New Mexico. Using R, (1) a principal axis factor analysis with promax (oblique) rotation was conducted, (2) a Schmid-Leiman transformation was attained, and (3) McDonald's omega and Cronbach's alpha were computed. Using SPSS, subscale findings were validated by conducting a principal axis factor analysis with promax rotation; strict parallels and Cronbach's alpha reliabilities were calculated. McDonald's omega and Cronbach's alpha were robust, with coefficients greater than 0.90; principal axis factor analysis with promax rotation revealed construct similarities with an overall general factor emerging from R. Further subjecting the PPDG to rigorous psychometric testing revealed stronger quantitative support of the overall general factor of directive guidance and subscales of instruction and feedback and goal-setting. Copyright © 2012 Elsevier Inc. All rights reserved.
A Latent Class Approach to Estimating Test-Score Reliability
ERIC Educational Resources Information Center
van der Ark, L. Andries; van der Palm, Daniel W.; Sijtsma, Klaas
2011-01-01
This study presents a general framework for single-administration reliability methods, such as Cronbach's alpha, Guttman's lambda-2, and method MS. This general framework was used to derive a new approach to estimating test-score reliability by means of the unrestricted latent class model. This new approach is the latent class reliability…
ERIC Educational Resources Information Center
Gadermann, Anne M.; Guhn, Martin; Zumbo, Bruno D.
2012-01-01
This paper provides a conceptual, empirical, and practical guide for estimating ordinal reliability coefficients for ordinal item response data (also referred to as Likert, Likert-type, ordered categorical, or rating scale item responses). Conventionally, reliability coefficients, such as Cronbach's alpha, are calculated using a Pearson…
Reliability and Validity Tests of Singelis's Self-Construal Scale (1994).
ERIC Educational Resources Information Center
Wang, Qi
Two studies focused on the reliability and validity of T.M. Singelis's 24-item Self-Construal Scale (SCS) (1994). In the first study, Cronbach alphas were calculated to assess the internal consistency of the reliability of the two subscales that were supposed to measure individuals' independent and interdependent self construals. The sample was…
ERIC Educational Resources Information Center
Zhang, Zhiyong; Yuan, Ke-Hai
2016-01-01
Cronbach's coefficient alpha is a widely used reliability measure in social, behavioral, and education sciences. It is reported in nearly every study that involves measuring a construct through multiple items. With non-tau-equivalent items, McDonald's omega has been used as a popular alternative to alpha in the literature. Traditional estimation…
ERIC Educational Resources Information Center
Zhang, Zhiyong; Yuan, Ke-Hai
2016-01-01
Cronbach's coefficient alpha is a widely used reliability measure in social, behavioral, and education sciences. It is reported in nearly every study that involves measuring a construct through multiple items. With non-tau-equivalent items, McDonald's omega has been used as a popular alternative to alpha in the literature. Traditional estimation…
Maizura, Husna; Masilamani, Retneswari; Aris, Tahir
2009-04-01
This small, cross-sectional study assessed the reliability of 3 scales from the Job Content Questionnaire (JCQ)-decision latitude, psychological job demand, and social support-in a group of office workers in a multinational company in Kuala Lumpur. A universal sample of 30 white-collar workers from a department of the company self-administered the English version of the JCQ comprising 21 core items selected from the full recommended version of 49 items on-site. Reliability (internal consistency) was evaluated using Cronbach's alpha coefficients for each scale. Corrected item-total correlation was presented for each and every item. Cronbach's alpha coefficients were acceptable for decision latitude (.76) and social support (.79) but slightly lower for psychological job demand (.64). Values for all item-total correlations for all 3 scales were greater than .3. In conclusion, this study suggests that the JCQ is a reliable scale for assessing job stress in this group of workers.
Alwi, N; Harun, D; Omar, B; Ahmad, M; Zagan, M; Leonard, J H
2015-01-01
Caregivers face challenges to adapt while handling individual with learning disabilities (LD). The Family Crisis Oriented Personal Evaluation Scale (F-COPES) is a widely used instrument to measure coping strategies among caregivers. The current study performed cross cultural translation of F-COPES in Malay language. This study aims to examine the reliability by testing internal consistency of Malay version of F-COPES which is developed through back to back translation method from original English version. The Malay version of F-COPES was administered among 30 caregivers. The reliability of F-COPES in Malay version is good with Cronbach's alpha coefficient value of 0.79. The internal consistency on sub domains of F-COPES such as reframing, acquiring social support and seeking spiritual support also acceptable with Cronbach's alpha values 0.67, 0.74, and 0.80, respectively. The Malay version of F-COPES is a reliable tool to evaluate the coping strategies adopted by the caregivers of individual with LD.
Quiroz, Viviana; Reinero, Daniela; Hernández, Patricia; Contreras, Johanna; Vernal, Rolando; Carvajal, Paola
2017-01-01
This study aimed to develop and assess the content validity and reliability of a cognitively adapted self-report questionnaire designed for surveillance of gingivitis in adolescents. Ten predetermined self-report questions evaluating early signs and symptoms of gingivitis were preliminary assessed by a panel of clinical experts. Eight questions were selected and cognitively tested in 20 adolescents aged 12 to 18 years from Santiago de Chile. The questionnaire was then conducted and answered by 178 Chilean adolescents. Internal consistency was measured using the Cronbach's alpha and temporal stability was calculated using the Kappa-index. A reliable final self-report questionnaire consisting of 5 questions was obtained, with a total Cronbach's alpha of 0.73 and a Kappa-index ranging from 0.41 to 0.77 between the different questions. The proposed questionnaire is reliable, with an acceptable internal consistency and a temporal stability from moderate to substantial, and it is promising for estimating the prevalence of gingivitis in adolescents.
Bayesian meta-analysis of Cronbach's coefficient alpha to evaluate informative hypotheses.
Okada, Kensuke
2015-12-01
This paper proposes a new method to evaluate informative hypotheses for meta-analysis of Cronbach's coefficient alpha using a Bayesian approach. The coefficient alpha is one of the most widely used reliability indices. In meta-analyses of reliability, researchers typically form specific informative hypotheses beforehand, such as 'alpha of this test is greater than 0.8' or 'alpha of one form of a test is greater than the others.' The proposed method enables direct evaluation of these informative hypotheses. To this end, a Bayes factor is calculated to evaluate the informative hypothesis against its complement. It allows researchers to summarize the evidence provided by previous studies in favor of their informative hypothesis. The proposed approach can be seen as a natural extension of the Bayesian meta-analysis of coefficient alpha recently proposed in this journal (Brannick and Zhang, 2013). The proposed method is illustrated through two meta-analyses of real data that evaluate different kinds of informative hypotheses on superpopulation: one is that alpha of a particular test is above the criterion value, and the other is that alphas among different test versions have ordered relationships. Informative hypotheses are supported from the data in both cases, suggesting that the proposed approach is promising for application. Copyright © 2015 John Wiley & Sons, Ltd.
Treating Cronbach's Alpha Reliability Coefficients as Data in Counseling Research
ERIC Educational Resources Information Center
Helms, Janet E.; Henze, Kevin T.; Sass, Terry L.; Mifsud, Venus A.
2006-01-01
Scientific associations and measurement experts in psychology and education have voiced various standards and best-practice recommendations concerning reliability data over the years. Yet in the counseling psychology literature, there is virtually no single-source compilation and articulation of good practices for reporting, analyzing, and…
Reliability Analysis of Money Habitudes
ERIC Educational Resources Information Center
Delgadillo, Lucy M.; Bushman, Brittani S.
2015-01-01
Use of the Money Habitudes exercise has gained popularity among various financial professionals. This article reports on the reliability of this resource. A survey administered to young adults at a western state university was conducted, and each Habitude or "domain" was analyzed using Cronbach's alpha procedures. Results showed all six…
Reliability of the ecSatter Inventory as a tool to measure eating competence.
Stotts, Jodi L; Lohse, Barbara
2007-01-01
To examine the reliability of the ecSatter Inventory (ecSI), a measure of eating competence. Self-report questionnaires were administered in person or by mail. Retesting occurred 2 to 6 weeks after completion of the first questionnaire. Both administrations of the questionnaire were completed by 259 participants who were mostly food secure, white females with some college education; mean age was 26.9 +/- 10.4 years. Test-retest reliability and internal consistency. Spearman's rank correlation coefficients to estimate test-retest reliability and Cronbach alpha coefficients to estimate internal consistency. Spearman's rank correlation coefficient for ecSI total score was 0.68; subscale coefficients were 0.70 for eating attitudes, 0.70 for contextual skills, 0.65 for food acceptance, and 0.52 for internal regulation. Cronbach alpha coefficient for ecSI total score was 0.77. Subscale alphas coefficients were 0.80 for eating attitudes, 0.69 for contextual skills, 0.68 for food acceptance, and 0.66 for internal regulation. This study provides psychometric evidence about the reliability of ecSI as a measure of eating competence in this sample. Although some ecSI items may require revision, results suggest that the instrument may be used to evaluate nutrition education designed to improve eating competence.
Xiao, Yu-Ying; Li, Ting; Xiao, Lin; Wang, Su-Wei; Wang, Si-Qi; Wang, Han-Xiao; Wang, Bei-Bei; Gao, Yu-Lin
2017-02-01
Professional attitude is of great importance for nursing talents in the modern society. To develop an effective educational program for student nurses in China, an appropriate instrument is required for the assessment of their professional attitude. To assess the validity and reliability of the Instrument of Professional Attitude for Student Nurses (IPASN) in Chinese version. The original version of IPASN was translated through Brislin model (translation, back translation, culture adaption and pilot study) with the authorization from the developer. A total of 681 nursing students were chosen by stratified convenience sampling to assess construct validity using exploratory factor analysis (EFA). Besides, item analysis, Cronbach's alpha coefficients, test-retest reliability were conducted to test the psychometric properties in this part. A total of 204 nursing undergraduate trainees were selected by cluster convenience sampling to confirm the structure using confirmatory factor analysis (CFA) in another time. Corrected item-total correlations, alpha if item deleted were between 0.33 and 0.69, 0.906 and 0.913, respectively, indicating no item should be deleted. Cronbach alpha value was 0.91 for the total scale and Cronbach alpha coefficient for subscales ranged from 0.67 to 0.89. Test-retest reliability estimated from intraclass correlation coefficient (ICC) was 0.74 (P<0.05). Differences in item scores between the high-score group (the first 27%) and low-score group (the last 27%) were significant (P<0.001), indicating that the item discrimination ability was good. Seven subscales (contribution to increase of scientific information load, autonomy, community service, continuous education, to promote professional development, cooperation and theory guiding practice) were identified in EFA and confirmed in CFA, and explained 65.5% of the total variance. It indicated that the Chinese version of IPASN was valid and reliable for the evaluation of nursing students' professional attitude. Copyright © 2016 Elsevier Ltd. All rights reserved.
Reliability and validity of the PedsQL™ Generic Core Scales 4.0 for Chinese children with epilepsy.
Duan, Xiaoling; Zhang, Shuqing; Xiao, Nong
2012-04-01
This investigation examines the reliability and validity of the Chinese version of the PedsQL 4.0 Generic Core Scales for prognostic measures of pediatric epilepsy. The study comprised 163 parents whose children, between the ages of 2 and 18 years, were diagnosed with epilepsy. The parents were given a questionnaire to be completed on behalf of the child. Reliability was assessed by Cronbach's alpha analysis. Validity was assessed by the exploratory factor analysis and intercorrelation analysis between the four subscales as well as Student's t-test. The internal consistency reliability for Total Scale Score was 0.94 by Cronbach's alpha test. Four major factors were extracted by factor analysis. The scores from all sub-scales derived from healthy children were significantly higher than children with epilepsy (P<0.001). The reliability and validity of the parent proxy-report scales from the Chinese version of the PedsQL™ 4.0 Generic Core Scales effectively matched the original version and could be used to evaluate the health-related quality of life of children with epilepsy. Copyright © 2012 Elsevier Inc. All rights reserved.
Tander, Berna; Ulus, Yasemin; Terzi, Yüksel; Zahiroğlu, Yeliz; Kesmen, Hakan; Farisoğullari, Bayram; Akyol, Yeşim; Bilgici, Ayhan; Kuru, Ömer
2016-12-01
This study aims to evaluate the reliability and validity of the Turkish language version of VITACORA-19 (psoriatic arthritis quality of life questionnaire) in patients with psoriatic arthritis. The Turkish version of VITACORA-19 questionnaire was obtained after a translation and back translation process. The study sample included 61 PsA patients (22 males, 39 females; mean age 46.5±12.2 years; range 19 to 71 years). To assess the test-retest reliability of the Turkish VITACORA-19, the questionnaire was reapplied 10 to 15 days after the first interview (interclass correlation coefficient). Cronbach's alpha (a) was used to evaluate the internal consistency. VITACORA-19 was compared with visual analog scale for physician and patient global assessments, the Health Assessment Questionnaire, and Nottingham Health Profile for construct validity. The internal structure of VITACORA-19 was examined by factor analysis. The individual item intraclass correlation coefficient ranged from 0.77 to 0.98 and Cronbach's alpha ranged from 0.77 to 0.98. The Cronbach's alpha value for whole scale was determined as 0.96. The Kaiser-Meyer-Olkin measure of sampling adequacy was 0.90, and Bartlett's test of sphericity had a p<0.001. Turkish VITACORA-19 total scores were correlated negatively with Health Assessment Questionnaire, visual analog scale for pain, and Nottingham Health Profile subgroups, and positively with physician and patient global assessments (p<0.01). Turkish version of VITACORA-19 questionnaire is a reliable and valid measure for health-related quality of life in Turkish patients with psoriatic arthritis.
The Validation of a Food Label Literacy Questionnaire for Elementary School Children
ERIC Educational Resources Information Center
Reynolds, Jesse S.; Treu, Judith A.; Njike, Valentine; Walker, Jennifer; Smith, Erica; Katz, Catherine S.; Katz, David L.
2012-01-01
Objective: To determine the reliability and validity of a 10-item questionnaire, the Food Label Literacy for Applied Nutrition Knowledge questionnaire. Methods: Participants were elementary school children exposed to a 90-minute school-based nutrition program. Reliability was assessed via Cronbach alpha and intraclass correlation coefficient…
Development and psychometric evaluation of the Professional Practice Environment (PPE) scale.
Erickson, Jeanette Ives; Duffy, Mary E; Gibbons, M Patricia; Fitzmaurice, Joan; Ditomassi, Marianne; Jones, Dorothy
2004-01-01
To describe the Professional Practice Environment (PPE) scale, its conceptual development and psychometric evaluation, and its uses in measuring eight characteristics of the professional practice environment in an acute care setting. The 38-item PPE Scale was validated on a sample of 849 professional practice staff at the Massachusetts General Hospital in Boston. Psychometric analysis included: item analysis, principal components analysis (PCA) with varimax rotation and Kaiser normalization, and internal consistency reliability using Cronbach's alpha coefficient. Eight components were shown, confirming the original conceptually derived model's structure and accounting for 61% of explained variance. Cronbach's alpha coefficients for the eight PPE subscales ranged from .78 to .88. Findings showed the 38-item PPE Scale was reliable and valid for use in health outcomes research to examine the professional practice environment of staff working in acute care settings.
Siliquini, R; Saulle, R; Rabacchi, G; Bert, F; Massimi, A; Bulzomì, V; Boccia, A; La Torre, G
2012-01-01
Objective of this pilot study was to evaluate the reliability and validity of the web-based questionnaire in pregnant women as a tool to examine prevalence, knowledge and attitudes about internet utilization for health-related purposes, in a sample of Italian pregnant women. The questionnaire was composed by 9 sections for a total of 73 items. Reliability analysis was tested and content validity was evaluated using Cronbach's alpha to check internal consistency. Statistical analysis was performed through SPSS 13.0. Questionnaire was administered to 56 pregnant women. The higher value of Cronbach's alpha resulted on 61 items: alpha = 0.786 (n. 73 items: alpha = 0.579). High rate of pregnant women generally utilized internet (87.5%) and the 92.1% confirmed to use internet with the focus to acquire information about pregnancy (p < 0.0001). The questionnaire showed a good reliability property in the pilot study. In terms of internal consistency and validity appeared to have a good performance. Given the high prevalence of pregnant women that use internet to search information about their pregnancy status, professional healthcare workers should give advice regarding official websites where they could retrieve safe information and learn knowledge based on scientific evidence.
Effect of Items Direction (Positive or Negative) on the Reliability in Likert Scale. Paper-11
ERIC Educational Resources Information Center
Gul, Showkeen Bilal Ahmad; Qasem, Mamun Ali Naji; Bhat, Mehraj Ahmad
2015-01-01
In this paper an attempt was made to analyze the effect of items direction (positive or negative) on the Alpha Cronbach reliability coefficient and the Split Half reliability coefficient in Likert scale. The descriptive survey research method was used for the study and sample of 510 undergraduate students were selected by used random sampling…
Nazary-Moghadam, Salman; Zeinalzadeh, Afsaneh; Salavati, Mahyar; Almasi, Simin; Negahban, Hossein
2017-01-01
The aim of the present study was to culturally adapt and evaluate reliability and validity of Health Assessment Questionnaire-Disability Index (HAQ-DI) in Iranian patients with rheumatoid arthritis (RA). 234 patients with RA for validation study, Eighty-six participants for reliability study. Test-retest relative reliability and internal consistency of Persian version of HAQ-DI were examined by intraclass correlation coefficient (ICC) and Cronbach's alpha, respectively. Additionally, HAQ-DI construct validity (Spearman's correlation) was examined using Persian version of Short-Form 36 Health survey (SF-36), activity and severity parameters. Persian version of HAQ-DI total score showed excellent test-retest reliability (ICC = 0.98) and internal consistency (Cronbach's alpha = 0.95). Spearman's correlations between the total PHAQ-DI score and activity and severity parameters were above 0.55. Correlation between PHAQ-DI and SF-36 Physical Health were higher as compared with SF-36 Mental Health. Persian version of HAQ-DI is a reliable and valid culturally-adapted instrument in order to measure functional limitations in Iranian people with RA. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ertuğ, Nurcan
2018-06-01
The aim of this study was to determine the validity and reliability of the Turkish version of the V-scale, which measures nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. This validity and reliability study was conducted at a tertiary hospital in Ankara, Turkey, in 2016. A total of 169 ward nurses participated in the study. Exploratory factor analysis, Cronbach's alpha coefficient, and the intraclass correlation coefficient were used to determine the validity and reliability of the scale. A 5-factor, 16-item scale explained 60.823% of the total variance according to the validity analysis. Our version matched the original scale in terms of the number of items and factor structure. Cronbach's alpha coefficient of the Turkish version of the V-scale was 0.764. The test-retest reliability results were 0.855 for the overall intraclass correlation coefficient, and the t-test result was P > 0.05. The V-scale is a reliable and valid instrument to measure Turkish nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. © 2018 John Wiley & Sons Australia, Ltd.
Development and Testing of the Nurse Manager EBP Competency Scale.
Shuman, Clayton J; Ploutz-Snyder, Robert J; Titler, Marita G
2018-02-01
The purpose of this study was to develop and evaluate the validity and reliability of an instrument to measure nurse manager competencies regarding evidence-based practice (EBP). The Nurse Manager EBP Competency Scale consists of 16 items for respondents to indicate their perceived level of competency on a 0 to 3 Likert-type scale. Content validity was demonstrated through expert panel review and pilot testing. Principal axis factoring and Cronbach's alpha evaluated construct validity and internal consistency reliability, respectively. Eighty-three nurse managers completed the scale. Exploratory factor analysis resulted in a 16-item scale with two subscales, EBP Knowledge ( n = 6 items, α = .90) and EBP Activity ( n = 10 items, α = .94). Cronbach's alpha for the entire scale was .95. The Nurse Manager EBP Competency Scale is a brief measure of nurse manager EBP competency with evidence of validity and reliability. The scale can enhance our understanding in future studies regarding how nurse manager EBP competency affects implementation.
Reliability of a questionnaire on substance use among adolescent students, Brazil.
Machado Neto, Adelmo de Souza; Andrade, Tarcisio Matos; Fernandes, Gilênio Borges; Zacharias, Helder Paulo; Carvalho, Fernando Martins; Machado, Ana Paula Souza; Dias, Ana Carmen Costa; Garcia, Ana Carolina Rocha; Santana, Lauro Reis; Rolin, Carlos Eduardo; Sampaio, Cyntia; Ghiraldi, Gisele; Bastos, Francisco Inácio
2010-10-01
To analyze reliability of a self-applied questionnaire on substance use and misuse among adolescent students. Two cross-sectional studies were carried out for the instrument test-retest. The sample comprised male and female students aged 1119 years from public and private schools (elementary, middle, and high school students) in the city of Salvador, Northeastern Brazil, in 2006. A total of 591 questionnaires were applied in the test and 467 in the retest. Descriptive statistics, the Kappa index, Cronbach's alpha and intraclass correlation were estimated. The prevalence of substance use/misuse was similar in both test and retest. Sociodemographic variables showed a "moderate" to "almost perfect" agreement for the Kappa index, and a "satisfactory" (>0.75) consistency for Cronbach's alpha and intraclass correlation. The age which psychoactive substances (tobacco, alcohol, and cannabis) were first used and chronological age were similar in both studies. Test-retest reliability was found to be a good indicator of students' age of initiation and their patterns of substance use. The questionnaire reliability was found to be satisfactory in the population studied.
De Coninck, Kyra; Hambly, Karen; Dickinson, John W; Passfield, Louis
2018-06-01
Chronic lower back pain is still regarded as a poorly understood multifactorial condition. Recently, the thoracolumbar fascia complex has been found to be a contributing factor. Ultrasound imaging has shown that people with chronic lower back pain demonstrate both a significant decrease in shear strain, and a 25% increase in thickness of the thoracolumbar fascia. There is sparse data on whether medical practitioners agree on the level of disorganisation in ultrasound images of thoracolumbar fascia. The purpose of this study was to establish inter-rater reliability of the ranking of architectural disorganisation of thoracolumbar fascia on a scale from 'very disorganised' to 'very organised'. An exploratory analysis was performed using a fully crossed design of inter-rater reliability. Thirty observers were recruited, consisting of 21 medical doctors, 7 physiotherapists and 2 radiologists, with an average of 13.03 ± 9.6 years of clinical experience. All 30 observers independently rated the architectural disorganisation of the thoracolumbar fascia in 30 ultrasound scans, on a Likert-type scale with rankings from 1 = very disorganised to 10 = very organised. Internal consistency was assessed using Cronbach's alpha. Krippendorff's alpha was used to calculate the overall inter-rater reliability. The Krippendorf's alpha was .61, indicating a modest degree of agreement between observers on the different morphologies of thoracolumbar fascia.The Cronbach's alpha (0.98), indicated that there was a high degree of consistency between observers. Experience in ultrasound image analysis did not affect constancy between observers (Cronbach's range between experienced and inexperienced raters: 0.95 and 0.96 respectively). Medical practitioners agree on morphological features such as levels of organisation and disorganisation in ultrasound images of thoracolumbar fascia, regardless of experience. Further analysis by an expert panel is required to develop specific classification criteria for thoracolumbar fascia.
Mantarova, Stefka G; Velcheva, Irena V; Georgieva, Spaska O; Stambolieva, Katerina I
2013-01-01
The last twenty years have witnessed a surge of interest in the autonomic symptoms in Parkinson's disease (PD) and the possibilities to diagnose and treat them. The specialized questionnaire assessing the autonomic symptoms in Parkinson's disease (SCOPA-AUT) has been validated and available in English, Dutch and Spanish. In this study we aim at evaluating the validity, reliability and applicability of the Bulgarian version of SCOPA-AUT (SCOPA-AUT-BG). The study included 55 patients with idiopathic PD (mean age 64.4 +/- 8.9 yrs), and 40 healthy controls (mean age 58.5 +/- 9.4 yrs). Clinical severity and disease stage were assessed by United Parkinson's disease rating scale (UPRDS) and Hoen and Yahr (H&Y). Thirty-two of the PD patients completed SCOPA-AUT-BG again after a 7-day interval. Questionnaire reliability was analyzed by determining the internal consistency, homogeneity, discriminatory and construct validity and test-retest reliability. Analyses showed good internal consistency of the summary evaluation of SCOPA-AUT-BG (coefficient alpha of Cronbach = 0.79), which indicates the high reliability of the questionnaire. The lowest Cronbach's alpha coefficient (0.53) was found for the subscale "cardiovascular functions". A dominant role belongs to the subscales for gastrointestinal and urinary functions (Cronbach's Alpha > 0.7), where a significantly high correlation of PD with the UPDRS scale was observed. We found high test-retest reliability based on the responses associated with dysfunction of the gastrointestinal, urinary, thermoregulatory and pupillary autonomic systems. The correlation of the results of SCOPA-AUT-BG with UPDRS is higher than that with H&Y, and the construct validity is high except for the cardiovascular and pupillomotor functions subscales. The results of this study show that SCOPA-AUT-BG is a valid and reliable specialized questionnaire to evaluate autonomic function in patients with Parkinson's disease. Using it allows for more detailed clinical evaluation of these patients and justifies the need to refer them to specialized examination of autonomic functions.
Trathitiphan, Warayos; Paholpak, Permsak; Sirichativapee, Winai; Wisanuyotin, Taweechok; Laupattarakasem, Pat; Sukhonthamarn, Kamolsak; Jeeravipoolvarn, Polasak; Kosuwon, Weerachai
2016-10-01
HOOS was developed as an extension of the Western Ontario and McMaster Universities' Osteoarthritis Index questionnaire for measuring symptoms and functional limitations related to the hip(s) of patients with osteoarthritis. To determine the validity and reliability of the Thai version of the Hip disability and Osteoarthritis Outcome Score (HOOS) vis-à-vis hip osteoarthritis, the original HOOS was translated into a Thai version of HOOS, according to international recommendations. Patients with hip osteoarthritis (n = 57; 25 males) were asked to complete the Thai version of HOOS twice: once then again after a 3-week interval. The test-retest reliability was analyzed using the intraclass correlation coefficient (ICC). Internal consistencies were analyzed using Cronbach's alpha, while the construct validity was tested by comparing the Thai HOOS with the Thai modified SF-36 and calculating the Spearman's rank correlation coefficients. The Thai HOOS produced good reliability (i.e., the ICC was greater than 0.9 in all five subscales). All of the Cronbach's alpha showed that the Thai HOOS had high internal consistency (Cronbach's alpha greater than 0.8), especially for the pain and ADL subscales (0.89 and 0.90, respectively). The Spearman's rank correlation for all five subscales of the Thai HOOS had moderate correlation with the Bodily Pain subscale of the Thai SF-36. The pain subscale of the Thai HOOS had a high correlation with the Vitality and Social Function subscales of the Thai SF-36 (r = 0.55 and 0.54)-with which the symptom subscale had a moderate correlation. The Thai version of HOOS had excellent internal consistency, excellent test-retest reliability, and good construct validity. It can be used as a reliable tool for assessing quality of life for patients with hip osteoarthritis in Thailand.
[Development of a scale to measure Korean ego-integrity in older adults].
Chang, Sung Ok; Kong, Eun Sook; Kim, Kwuy Bun; Kim, Nam Cho; Kim, Ju Hee; Kim, Chun Gill; Kim, Hee Kyung; Song, Mi Soon; Ahn, Soo Yeon; Lee, Kyung Ja; Lee, Young Whee; Chon, Si Ja; Cho, Nam Ok; Cho, Myung Ok; Choi, Kyung Sook
2007-04-01
Ego-integrity in older adults is the central concept related to quality of life in later life. Therefore, for effective interventions to enhance the quality of later life, a scale to measure ego-integrity in older adults is necessary. This study was carried out to develop a scale to measure ego-integrity in older adults. This study utilized cronbach's alpha in analyzing the reliability of the collected data and expert group, and factor analysis and item analysis to analyze validity. Seventeen items were selected from a total of 21 items. Cronbach's alpha coefficient for internal consistency was .88 for the 17 items of ego-integrity in the older adults scale. Three factors evolved by factor analysis, which explained 50.71% of the total variance. The scale for measuring ego-integrity in Korean older adults in this study was evaluated as a tool with a high degree of reliability and validity.
Validation of a Korean Version of the Tinnitus Handicap Questionnaire
Yoo, Ik Won; Hwang, Sun Jin; Hwang, Soon Young
2015-01-01
Objectives The goal of the present study was to evaluate the reliability and validity of the Korean version of the tinnitus handicap questionnaire (THQ-K). Methods A total of 60 patients were included in this study. Patients responded to the THQ-K, the tinnitus handicap inventory (THI), Beck's depression index (BDI), and the visual analogue scale (VAS) for loudness and pitch, loudness match, and minimum masking level (MML) test were performed. Results Internal consistency of the THQ-K was examined using Cronbach coefficient alpha. Cronbach alpha was 0.96. The THQ-K showed a significant correlation with THI, BDI, VAS for distress, and VAS for loudness, but no significant correlation with psychoacoustic measurement of tinnitus, such as loudness match, pitch match, and MML. Conclusion The THQ-K is a reliable and valid test for evaluating the degree of handicap due to tinnitus for both research and clinical use. PMID:26330911
La Torre, G; Sestili, C; Iavazzo, E; Mannocci, A
2017-01-01
The phenomenon of violence and aggression in the workplace is frequent and constantly increasing. Healthcare professionals are most exposed to this phenomenon, especially those who work in urgent and psychiatric emergency departments. To validate the Italian version of the questionnaire "Workplace Violence in the Health Sector Case Study Research Instruments Survey Questionnaire", conducted by WHO. 55 randomly selected workers took part in the validation of the questionnaire among physicians, nurses and nursing trainees. The internal consistency analysis of the demand of 5 dichotomous variables on binary values for violence levels suggests that Cronbach's alpha is 0.61, and Cronbach's alpha calculated on standardized elements is 0.69, which means that Reliability shows sufficient levels. The Italian translation carried out in this WHO questionnaire study shows good internal reliability and consistency and could be considered a useful tool in assessing and preventing aggression and violence against health professionals.
Eren, Nurhan
2014-12-01
In this study, we aimed to develop two reliable and valid assessment instruments for investigating the level of difficulties mental health workers experience while working with patients with personality disorders and the attitudes they develop tt the patients. The research was carried out based on the general screening model. The study sample consisted of 332 mental health workers in several mental health clinics of Turkey, with a certain amount of experience in working with personality disorders, who were selected with a random assignment method. In order to collect data, the Personal Information Questionnaire, Difficulty of Working with Personality Disorders Scale (PD-DWS), and Attitudes Towards Patients with Personality Disorders Scale (PD-APS), which are being examined for reliability and validity, were applied. To determine construct validity, the Adjective Check List, Maslach Burnout Inventory, and State and Trait Anxiety Inventory were used. Explanatory factor analysis was used for investigating the structural validity, and Cronbach alpha, Spearman-Brown, Guttman Split-Half reliability analyses were utilized to examine the reliability. Also, item reliability and validity computations were carried out by investigating the corrected item-total correlations and discriminative indexes of the items in the scales. For the PD-DWS KMO test, the value was .946; also, a significant difference was found for the Bartlett sphericity test (p<.001). The computed test-retest coefficient reliability was .702; the Cronbach alpha value of the total test score was .952. For PD-APS KMO, the value was .925; a significant difference was found in Bartlett sphericity test (p<.001); the computed reliability coefficient based on continuity was .806; and the Cronbach alpha value of the total test score was .913. Analyses on both scales were based on total scores. It was found that PD-DWS and PD-APS have good psychometric properties, measuring the structure that is being investigated, are compatible with other scales, have high levels of internal reliability between their items, and are consistent across time. Therefore, it was concluded that both scales are valid and reliable instruments.
Narin, Selnur; Unver, Bayram; Bakırhan, Serkan; Bozan, Ozgür; Karatosun, Vasfi
2014-01-01
The purpose of this study was to adapt the English version of the Hospital for Special Surgery (HSS) knee score for use in a Turkish population and to evaluate its validity, reliability and cultural adaptation. Standard forward-back translation of the HSS knee score was performed and the Turkish version was applied in 73 patients. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Mini-Mental State Examination and sit-to-stand test were also performed and analyzed. Internal consistency reliability was tested using Cronbach's alpha. The intraclass correlation coefficient (ICC) was used to calculate the test-retest reliability at one-week intervals. Validity was assessed by calculating the Pearson correlation between the HSS, WOMAC and sit-to-stand test scores. The ICC ranged from 0.98 to 0.99 with high internal consistency (Cronbach's alpha: 0.87). The WOMAC score correlated with total HSS score (r: -0.80, p<0.001) and sit-to-stand score (r: 0.12, p: 0.312). The Turkish version of the HSS knee score is reliable and valid in evaluating the total knee arthroplasty in Turkish patients.
Sajjad, Madiha; Khan, Rehan Ahmed; Yasmeen, Rahila
2018-01-01
To develop a tool to evaluate faculty perceptions of assessment quality in an undergraduate medical program. The Assessment Implementation Measure (AIM) tool was developed by a mixed method approach. A preliminary questionnaire developed through literature review was submitted to a panel of 10 medical education experts for a three-round 'Modified Delphi technique'. Panel agreement of > 75% was considered the criterion for inclusion of items in the questionnaire. Cognitive pre-testing of five faculty members was conducted. Pilot study was done with 30 randomly selected faculty members. Content validity index (CVI) was calculated for individual items (I-CVI) and composite scale (S-CVI). Cronbach's alpha was calculated to determine the internal consistency reliability of the tool. The final AIM tool had 30 items after the Delphi process. S-CVI was 0.98 with the S-CVI/Avg method and 0.86 by S-CVI/UA method, suggesting good content validity. Cut-off value of < 0.9 I-CVI was taken as criterion for item deletion. Cognitive pre-testing revealed good item interpretation. Cronbach's alpha calculated for the AIM was 0.9, whereas Cronbach's alpha for the four domains ranged from 0.67 to 0.80. 'AIM' is a relevant and useful instrument with good content validity and reliability of results, and may be used to evaluate the teachers´ perceptions about assessment quality.
The Score Reliability of Draw-a-Person Intellectual Ability Test (DAP: IQ) for Rural Malawi Students
ERIC Educational Resources Information Center
Khasu, Denis S.; Williams, Thomas O., Jr.
2016-01-01
In this brief article, the reliability of scores for the Draw-A-Person Intellectual Ability Test for Children, Adolescents, and Adults (DAP: IQ; Reynolds & Hickman, 2004) was examined through several analyses with a sample of 147 children from rural Malawi, Africa using a Chichewa translation of instructions. Cronbach alpha coefficients for…
ERIC Educational Resources Information Center
Hatami, Gissou; Motamed, Niloofar; Ashrafzadeh, Mahshid
2010-01-01
Validity and reliability of Persian adaptation of MSLSS in the 12-18 years, middle and high school students (430 students in grades 6-12 in Bushehr port, Iran) using confirmatory factor analysis by means of LISREL statistical package were checked. Internal consistency reliability estimates (Cronbach's coefficient [alpha]) were all above the…
ERIC Educational Resources Information Center
Barnette, J. Jackson
2005-01-01
An Excel program developed to assist researchers in the determination and presentation of confidence intervals around commonly used score reliability coefficients is described. The software includes programs to determine confidence intervals for Cronbachs alpha, Pearson r-based coefficients such as those used in test-retest and alternate forms…
Development of Social Media Addiction Test (SMAT17)
ERIC Educational Resources Information Center
Esgi, Necmi
2016-01-01
The aim of this study was to develop a test for assessing individuals' social media addiction; and conducting a reliability and validity study of this scale. Sample for this study was composed of 285 college students between the ages of 18 and 25. Reliability coefficients Cronbach's alpha value was 0.94 and Spearman Brown value was 0.91 for our…
Lessa, Paula Renata Amorim; Ribeiro, Samila Gomes; Aquino, Priscila de Souza; de Almeida, Paulo Cesar; Pinheiro, Ana Karina Bezerra
2015-01-01
Objectives: the aim was to translate and culturally adapt the Adherence Determinants Questionnaire scale for the Portuguese language in the Brazilian context, and to check its reliability and validity to analyze the elements of the adherence of patients to the clinical treatment for breast and cervical cancer. Method: this was a methodological study, carried out in two oncology reference centers. The sample consisted of 198 participants, with 152 being treated for breast cancer and 46 being treated for cervical cancer. The content validation was performed by a committee of experts. The construct validation was demonstrated through factor analysis and the reliability was analyzed using Cronbach's alpha. Results: the committee of experts made the necessary adjustments so that the scale was adapted to the Brazilian context. The factor analysis suggested a reduction from seven to five factors and the maintenance of 38 items similar to those of the original scale. The reliability, investigated through Cronbach's alpha, was .829, showing high internal consistency. Conclusion: it was concluded that the Brazilian version of the Adherence Determinants Questionnaire scale is a valid and reliable instrument that is able to measure the elements of adherence to the treatment for breast and cervical cancer. PMID:26487149
Reliability of adapted version of Italian Label tobacco Impact Index for the adolescent: ALII.
Guerra, F; Mannocci, A; Colamesta, V; De Luca, G; Fiore, M; Firenze, A; Ferrara, M; Langiano, E; De Vito, E; Bonaccorsi, G; La Torre, G
2017-01-01
The aim of this study is to assess the reliability of the Adolescent Label Impact Index (ALII) , it is an adolescent adapted version of Italian LII of the tobacco products warnings. A sample including students aged 13-15 years was considered. The ALII is constructed by 4 items: salience, harm, quitting and forgo. The questionnaire was self-administered to study participants twice with 3 days between each administration (T1 and T2) to measure reliability. The internal consistency using Cronbach's alpha and Corrected Item-Total Correlations (CITC) and the test-retest reliability applying Pearson's correlation were computed. Cronbach's alpha ranges from 0.625 at T1 to 0.715 at T2. The "salience" resulted the item with the lowest CITC value (=0.281). The Pearson's coefficient was r=0.909 (p<0.001). The instruments is low in cost and easy to administer and analyses in a setting people aged 13-15 years. The ALII shown an acceptable consistency and excellent stability over time. However, attention has to be paid when the ALII is administered to the no smoking teens and who has never seen the tobacco product labels to allow an appropriate interpretation of the data collected.
Tabrizi, Yousef Moghadas; Zangiabadi, Nasser; Mazhari, Shahrzad; Zolala, Farzaneh
2013-01-01
Objective Motor imagery (MI) has been recently considered as an adjunct to physical rehabilitation in patients with multiple sclerosis (MS). It is necessary to assess MI abilities and benefits in patients with MS by using a reliable tool. The Kinesthetic and Visual Imagery Questionnaire (KVIQ) was recently developed to assess MI ability in patients with stroke and other disabilities. Considering the different underlying pathologies, the present study aimed to examine the validity and reliability of the KVIQ in MS patients. Method Fifteen MS patients were assessed using the KVIQ in 2 sessions (5-14days apart) by the same examiner. In the second session, the participants also completed a revised MI questionnaire (MIQ-R) as the gold standard. Intra-class correlation coefficients (ICCs) were measured to determine test-retest reliability. Spearman's correlation analysis was performed to assess concurrent validity with the MIQ-R. Furthermore, the internal consistency (Cronbach's alpha) and factorial structure of the KVIQ were studied. Results The test-retest reliability for the KVIQ was good (ICCs: total KVIQ=0.89, visual KVIQ=0.85, and kinesthetic KVIQ=0.93), and the concurrent validity between the KVIQ and MIQ-R was good (r=0.79). The KVIQ had good internal consistency, with high Cronbach's alpha (alpha=0.84). Factorial analysis showed the bi-factorial structure of the KVIQ, which was explained by visual=57.6% and kinesthetic=32.4%. Conclusions The results of the present study revealed that the KVIQ is a valid and reliable tool for assessing MI in MS patients. PMID:24271091
Tabrizi, Yousef Moghadas; Zangiabadi, Nasser; Mazhari, Shahrzad; Zolala, Farzaneh
2013-01-01
Motor imagery (MI) has been recently considered as an adjunct to physical rehabilitation in patients with multiple sclerosis (MS). It is necessary to assess MI abilities and benefits in patients with MS by using a reliable tool. The Kinesthetic and Visual Imagery Questionnaire (KVIQ) was recently developed to assess MI ability in patients with stroke and other disabilities. Considering the different underlying pathologies, the present study aimed to examine the validity and reliability of the KVIQ in MS patients. Fifteen MS patients were assessed using the KVIQ in 2 sessions (5-14 days apart) by the same examiner. In the second session, the participants also completed a revised MI questionnaire (MIQ-R) as the gold standard. Intra-class correlation coefficients (ICCs) were measured to determine test-retest reliability. Spearman's correlation analysis was performed to assess concurrent validity with the MIQ-R. Furthermore, the internal consistency (Cronbach's alpha) and factorial structure of the KVIQ were studied. The test-retest reliability for the KVIQ was good (ICCs: total KVIQ=0.89, visual KVIQ=0.85, and kinesthetic KVIQ=0.93), and the concurrent validity between the KVIQ and MIQ-R was good (r=0.79). The KVIQ had good internal consistency, with high Cronbach's alpha (alpha=0.84). Factorial analysis showed the bi-factorial structure of the KVIQ, which was explained by visual=57.6% and kinesthetic=32.4%. The results of the present study revealed that the KVIQ is a valid and reliable tool for assessing MI in MS patients.
Miki, Emi; Yamane, Shingo; Yamaoka, Mai; Fujii, Hiroe; Ueno, Hiroka; Kawahara, Toshie; Tanaka, Keiko; Tamashiro, Hiroaki; Inoue, Eiji; Okamoto, Takatsugu; Kuriyama, Masaru
2016-09-01
The study aim was to investigate the validity and reliability of the Functional Independence Measure and Functional Assessment Measure (FIM + FAM), which is unfamiliar in Japan, by using its Japanese version (FIM + FAM-j) in patients with cerebrovascular accident (CVA). Forty-two CVA patients participated. Criterion validity was examined by correlating the full scale and subscales of FIM + FAM-j with several well-established measurements using Spearman's correlation coefficient. Reliability was evaluated by internal consistency (tested by Cronbach's alpha coefficient) and intra-rater reliability (tested by Kendall's tau correlation coefficient). Good-to-excellent criterion validity was found between the full scale and motor subscales of the FIM + FAM-j and the Barthel Index, National Institutes of Health Stroke Scale, modified Rankin Scale, and lower extremity Brunnstrom Recovery Stage. High internal consistency was observed within the full-scale FIM + FAM-j and the motor and cognitive subscales (Cronbach's alphas were 0.968, 0.954, and 0.948, respectively). Additionally, good intra-rater reliability was observed within the full scale and motor subscales, and excellent reliability for the cognitive subscales (taus were 0.83, 0.80, and 0.98, respectively). This study showed that the FIM + FAM-j demonstrated acceptable levels of validity and reliability when used for CVA as a measure of disability.
A rating instrument for fear of hospitalisation.
Jankovic, Slobodan M; Antonijevic, Gordana V; Vasic, Ivana R; Zivkovic-Radojevic, Marija N; Mirkovic, Snjezana N; Nikolic, Bosko V; Opancina, Valentina D; Putnik, Srdjan S; Radoicic, Ljiljana R; Raspopovic, Katarina M; Stanojevic, Dragan R; Teofilov, Sladjana D; Tomasevic, Katarina V; Radonjic, Vesela
2018-04-01
To develop and validate a reliable instrument that can measure fear of hospitalisation experienced by outpatients. After having a diagnosis established, some patients experience sense of fear, unpleasantness and embarrassment due to the possibility to be admitted to a hospital. Currently, there is no available instrument for measuring fear of hospitalisation. Cross-sectional study for assessing reliability and validity of a questionnaire. The questionnaire with 17 items and answers according to the Likert scale was developed during two brainstorming sessions of the research team. Its reliability, validity and temporal stability were tested on the sample of 330 outpatients. The study was multicentric, involving patients from seven cities and three countries. Fear of hospitalisation scale showed satisfactory reliability, when rated both by the investigators (Cronbach's alpha .799) and by the patients themselves (Cronbach's alpha .760). It is temporally stable, and both divergent and convergent validity tests had good results. Factorial analysis revealed three domains: fear of being injured, trust to medical staff and fear of losing privacy or autonomy. This study developed new reliable and valid instrument for measuring fear of hospitalisation. Identification of patients with high level of fear of hospitalisation by this instrument should help clinicians to administer measures which may decrease fear and prevent avoidance of healthcare utilisation. © 2018 John Wiley & Sons Ltd.
Health Service Quality Scale: Brazilian Portuguese translation, reliability and validity.
Rocha, Luiz Roberto Martins; Veiga, Daniela Francescato; e Oliveira, Paulo Rocha; Song, Elaine Horibe; Ferreira, Lydia Masako
2013-01-17
The Health Service Quality Scale is a multidimensional hierarchical scale that is based on interdisciplinary approach. This instrument was specifically created for measuring health service quality based on marketing and health care concepts. The aim of this study was to translate and culturally adapt the Health Service Quality Scale into Brazilian Portuguese and to assess the validity and reliability of the Brazilian Portuguese version of the instrument. We conducted a cross-sectional, observational study, with public health system patients in a Brazilian university hospital. Validity was assessed using Pearson's correlation coefficient to measure the strength of the association between the Brazilian Portuguese version of the instrument and the SERVQUAL scale. Internal consistency was evaluated using Cronbach's alpha coefficient; the intraclass (ICC) and Pearson's correlation coefficients were used for test-retest reliability. One hundred and sixteen consecutive postoperative patients completed the questionnaire. Pearson's correlation coefficient for validity was 0.20. Cronbach's alpha for the first and second administrations of the final version of the instrument were 0.982 and 0.986, respectively. For test-retest reliability, Pearson's correlation coefficient was 0.89 and ICC was 0.90. The culturally adapted, Brazilian Portuguese version of the Health Service Quality Scale is a valid and reliable instrument to measure health service quality.
Naeem, Naghma; Muijtjens, Arno
2015-04-01
The psychological construct of emotional intelligence (EI), its theoretical models, measurement instruments and applications have been the subject of several research studies in health professions education. The objective of the current study was to investigate the factorial validity and reliability of a bilingual version of the Schutte Self Report Emotional Intelligence Scale (SSREIS) in an undergraduate Arab medical student population. The study was conducted during April-May 2012. A cross-sectional survey design was employed. A sample (n = 467) was obtained from undergraduate medical students belonging to the male and female medical college of King Saud University, Riyadh, Saudi Arabia. Exploratory and confirmatory factor analysis was performed using SPSS 16.0 and AMOS 4.0 statistical software to determine the factor structure. Reliability was determined using Cronbach's alpha statistics. The results obtained using an undergraduate Arab medical student sample supported a multidimensional; three factor structure of the SSREIS. The three factors are Optimism, Awareness-of-Emotions and Use-of-Emotions. The reliability (Cronbach's alpha) for the three subscales was 0.76, 0.72 and 0.55, respectively. Emotional intelligence is a multifactorial construct (three factors). The bilingual version of the SSREIS is a valid and reliable measure of trait emotional intelligence in an undergraduate Arab medical student population.
Fonseca, Rochele Paz; Joanette, Yves; Côté, Hélène; Ska, Bernadette; Giroux, Francine; Fachel, Jandyra Maria Guimarães; Damasceno Ferreira, Gabriela; Parente, Maria Alice de Mattos Pimenta
2008-11-01
The lack of standardized instruments to evaluate communication disorders related to the right hemisphere was verified. A new evaluation tool was developed: Protocole Montréal d'Evaluation de la Communication--Protocole MEC, adapted to Brazilian Portuguese--Bateria Montreal de Avaliação da Comunicação--Bateria MAC (Montreal Evaluation of Communication Battery). The purpose was to present stratified normative data by age and educational level, and to verify the reliability parameters of the MEC Battery. 300 individuals, between the ages of 19 and 75 years, and levels of formal education between 2 and 35 years, participated in this study. They were divided equally into six normative groups, according to three age categories (young adults, intermediary age, and seniors) and two educational levels (low and high). Two procedures were used to check reliability: Cronbach alpha and reliability between evaluators, Results were established at the 10th percentile, and an alert point per task for each normative group. Cronbach's alpha was, in general, between .70 and .90 and the average rate of agreement between evaluators varied from .62 to .94. Standards of age and education were established. The reliability of this instrument was verified. The psychometric legitimization of the MEC Battery will contribute to the diagnostic process for communicative disorders.
Validation in the cross-cultural adaptation of the Korean version of the Oswestry Disability Index.
Jeon, Chang-Hoon; Kim, Dong-Jae; Kim, Se-Kang; Kim, Dong-Jun; Lee, Hwan-Mo; Park, Heui-Jeon
2006-12-01
Disability questionnaires are used for clinical assessment, outcome measurement, and research methodology. Any disability measurement must be adapted culturally for comparability of data, when the patients, who are measured, use different languages. This study aimed to conduct cross-cultural adaptation in translating the original (English) version of the Oswestry Disability Index (ODI) into Korean, and then to assess the reliability of the Korean versions of the Oswestry Disability Index (KODI). We used methodology to obtain semantic, idiomatic, experimental, and conceptual equivalences for the process of cross-cultural adaptation. The KODI were tested in 116 patients with chronic low back pain. The internal consistency and reliability for the KODI reached 0.9168 (Cronbach's alpha). The test-retest reliability was assessed with 32 patients (who were not included in the assessment of Cronbach's alpha) over a time interval of 4 days. Test-retest correlation reliability was 0.9332. The entire process and the results of this study were reported to the developer (Dr. Fairbank JC), who appraised the KODI. There is little evidence of differential item functioning in KODI. The results suggest that the KODI is internally consistent and reliable. Therefore, the KODI can be recommended as a low back pain assessment tool in Korea.
Validation in the Cross-Cultural Adaptation of the Korean Version of the Oswestry Disability Index
Kim, Dong-Jae; Kim, Se-Kang; Kim, Dong-Jun; Lee, Hwan-Mo; Park, Heui-Jeon
2006-01-01
Disability questionnaires are used for clinical assessment, outcome measurement, and research methodology. Any disability measurement must be adapted culturally for comparability of data, when the patients, who are measured, use different languages. This study aimed to conduct cross-cultural adaptation in translating the original (English) version of the Oswestry Disability Index (ODI) into Korean, and then to assess the reliability of the Korean versions of the Oswestry Disability Index (KODI). We used methodology to obtain semantic, idiomatic, experimental, and conceptual equivalences for the process of cross-cultural adaptation. The KODI were tested in 116 patients with chronic low back pain. The internal consistency and reliability for the KODI reached 0.9168 (Cronbach's alpha). The test-retest reliability was assessed with 32 patients (who were not included in the assessment of Cronbach's alpha) over a time interval of 4 days. Test-retest correlation reliability was 0.9332. The entire process and the results of this study were reported to the developer (Dr. Fairbank JC), who appraised the KODI. There is little evidence of differential item functioning in KODI. The results suggest that the KODI is internally consistent and reliable. Therefore, the KODI can be recommended as a low back pain assessment tool in Korea. PMID:17179693
2014-07-01
Telephone: 1300 333 362 Fax: (03) 9626 7999 © Commonwealth of Australia 2014 AR-016-028 July 2014 APPROVED FOR PUBLIC RELEASE... Pallant , 2007; Steiner & Norman, 2003). Validity is assessed using nomological network and its relationship to item construction using theoretical...alpha (Cronbach, 1951; De Vellis, 2003; Nunnally, 1978; Pallant , 2007; Streiner & Norman, 2003, 2008). Cronbach’s alpha builds on the utility of the
Alavi, Seyyed Salman; Maracy, Mohammad Reza; Jannatifard, Fereshte; Ojaghi, Rezvan; Rezapour, Hossein
2014-01-01
A number of diagnostic scales or questionnaires have been developed in recent years, to assess mobile phone dependency. A valid and reliable assessment instrument for correspondence of Iranian culture is essential. The aim of our study is to validate the Iranian version of the Cell Phone Dependency Questionnaire (CPDQ). In this cross-sectional study, data were collected from 784 students, who were studying in four main Isfahan Universities. The participants completed the demographic questionnaire, CPDQ, anonymously. To analyze the data we used concurrent validity, factor analysis, internal consistency, split-half, and test-retest. We extracted three factors including Salience, Overusing of the cell phone, compulsive use of SMS. Cronbach's alpha of the CPDQ was. 88 (Cronbach's alpha of the factors were 0.85, 0.70, and 0.76, respectively). The CPDQ proved to be a reliable questionnaire to assess the extent of problems caused by the 'misuse' of the cell phone in Iranian society.
ERIC Educational Resources Information Center
Hua, Jing; Gu, Guixiong; Meng, Wei; Wu, Zhuochun
2013-01-01
The aim of this paper was to examine the validity and reliability of age band 1 of the Movement Assessment Battery for Children-Second Edition (MABC-2) in preparation for its standardization in mainland China. Interrater and test-retest reliability of the MABC-2 was estimated using Intraclass Correlation Coefficient (ICC). Cronbach's alpha for…
ERIC Educational Resources Information Center
Bitsika, Vicki; Sharpley, Christopher F.
2018-01-01
The validity, reliability and factor structure of the Autism Spectrum Disorder Behaviour Checklist-Revised (ASDBC-R) were measured in a sample of 140 boys with Autism Spectrum Disorder (ASD) aged between 6 and 18 years. Internal consistency (Cronbach's alpha) was satisfactory and the ASDBC-R significantly correlated with the Social Responsiveness…
Cognitive emotion regulation questionnaire in hypertensive patients.
Duan, Shu; Liu, Yiqun; Xiao, Jing; Zhao, Shuiping; Zhu, Xiongzhao
2011-06-01
To examine the reliability,validity,and practicability of Cognitive Emotion Regulation Questionnaire (CERQ) in hypertensive patients in China. Altogether 434 hypertensive patients and 462 healthy subjects were recruited. All the subjects were assessed with the CERQ-Chinese version (CERQ-C), Dysfunctional Attitude Scale (DAS), Mood and Anxiety Symptom Questionnaire-Short Form (MASQ-SF), and Center for Epidemiologic Studies Depression Scale (CES-D). We calculated the mean inter-item correlations for the total CERQ and for each of the subscales. Cronbach's alpha coefficient was used to analyze the inter-correlation and reliability, and confirmatory factor analysis was used to examine the 9-factor model. 1) Hypertension group reported significantly higher score than that of healthy ones on rumination (12.19 ± 2.51 vs. 11.51 ± 2.60, P<0.001), catastrophizing(8.82 ± 2.19 vs.8.11 ± 2.70,P<0.001),and blaming others(10.76 ± 2.11 vs. 9.88 ± 2.48,P<0.001), and had significantly lower score than that of healthy ones on positive reappraisal(13.80 ± 3.55 vs.14.71 ± 4.11,P<0.001).2)Reliability:In the hypertension group the Cronbach's alpha for the total CERQ was 0.80, and that for the 9 subscales ranged from 0.71 (self-blame) to 0.90 (rumination). In the healthy group the Cronbach's alpha for the total CERQ was 0.79, and that for the 9 subscales ranged from 0.71 (positive reappraisal) to 0.90 (rumination). The mean inter-item correlation coefficient for the 9 subscales was 0.21-0.42(the hypertension group)/0.19-0.32 (the healthy group). In the hypertension group,the test-retest reliability of the total scale was 0.82, the test-retest reliability of the 9 subscales ranged from 0.73 to 0.92. The confirmatory factor analysis showed that the 9 first-order factor data fitted both 2 samples well. CERQ meets the psychometric standard and it is reliable and valid for cognitive emotion regulation strategies, which may be regarded as an appropriate assessment tool.
Espinoza-Venegas, Maritza; Sanhueza-Alvarado, Olivia; Ramírez-Elizondo, Noé; Sáez-Carrillo, Katia
2015-01-01
OBJECTIVE: The current study aimed to validate the construct and reliability of an emotional intelligence scale. METHOD: The Trait Meta-Mood Scale-24 was applied to 349 nursing students. The process included content validation, which involved expert reviews, pilot testing, measurements of reliability using Cronbach's alpha, and factor analysis to corroborate the validity of the theoretical model's construct. RESULTS: Adequate Cronbach coefficients were obtained for all three dimensions, and factor analysis confirmed the scale's dimensions (perception, comprehension, and regulation). CONCLUSION: The Trait Meta-Mood Scale is a reliable and valid tool to measure the emotional intelligence of nursing students. Its use allows for accurate determinations of individuals' abilities to interpret and manage emotions. At the same time, this new construct is of potential importance for measurements in nursing leadership; educational, organizational, and personal improvements; and the establishment of effective relationships with patients. PMID:25806642
Kaiser, Gudrun; Kues, Johanna N; Kleinstäuber, Maria; Andersson, Gerhard; Weise, Cornelia
2017-11-07
During the premenstrual phase, psychological and physiological changes can occur, which are associated with different levels of disability. When they appear with Premenstrual Dysphoric Disorder (PMDD), different coping strategies may be used by women to deal with premenstrual changes. Currently no German measure exists for assessing premenstrual symptom-related coping strategies. Therefore, we developed the Premenstrual Change Coping Inventory (PMS-Cope). First, the 33-item questionnaire was tested with an exploratory factor analytic approach (EFA) in a sample of 150 women prospectively diagnosed with PMDD or severe Premenstrual Syndrome from August 2013 until March 2016. The EFA resulted in a 12-item scale with a two-factor structure: "seeking positive affect-inducing activities" and "seeking support"; Cronbach`s alpha of 0.73 and 0.71, respectively, demonstrated good reliability for both factors. Confirmatory factor analysis based on a second sample of 89 women conducted from May 2016 until June 2016 confirmed the two-factor structure. Additionally, a potential third factor "healthcare use behavior" was tested with an EFA. For the three-factor solution, satisfactory Cronbach's alpha values (0.70-0.72) were detected. The PMS-Cope was shown to be a valid, reliable, and economic measure. In future research, cross validations and confirmatory factor analyses with the three-factor solution should be conducted.
Salavati, M; Waninge, A; Rameckers, E A A; de Blécourt, A C E; Krijnen, W P; Steenbergen, B; van der Schans, C P
2015-02-01
The aims of this study were to adapt the Paediatric Evaluation of Disability Inventory, Dutch version (PEDI-NL) for children with cerebral visual impairment (CVI) and cerebral palsy (CP) and determine test-retest and inter-respondent reliability. The Delphi method was used to gain consensus among twenty-one health experts familiar with CVI. Test-retest and inter-respondent reliability were assessed for parents and caregivers of 75 children (aged 50-144 months) with CP and CVI. The percentage identical scores of item scores were computed, as well as the interclass coefficients (ICC) and Cronbach's alphas of scale scores over the domains self-care, mobility, and social function. All experts agreed on the adaptation of the PEDI-NL for children with CVI. On item score, for the Functional Skills scale, mean percentage identical scores variations for test-retest reliability were 73-79 with Caregiver Assistance scale 73-81, and for inter-respondent reliability 21-76 with Caregiver Assistance scale 40-43. For all scales over all domains ICCs exceeded 0.87. For the domains self-care, mobility, and social function, the Functional Skills scale and the Caregiver Assistance scale have Cronbach's alpha above 0.88. The adapted PEDI-NL for children with CP and CVI is reliable and comparable to the original PEDI-NL. Copyright © 2014 Elsevier Ltd. All rights reserved.
Erel, Suat; Şimşek, İbrahim Engin; Özkan, Hüseyin
2015-01-01
The aim of this study was to analyze the validity and reliability of the Turkish version (ICOAP-TR) of the intermittent and constant osteoarthritis pain (ICOAP) questionnaire in patients with knee osteoarthritis (OA). Thirty-eight volunteer patients diagnosed with knee OA answered the questionnaire twice with an interval of 2-4 days. The reliability of the measurement was assessed using Cronbach's alpha coefficient and intraclass correlation (ICC) for test-retest reliability. Criterion validity was tested against the Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain score and visual analog scale (VAS) designed to assess the perceived discomfort rated by the patient. Test-retest reliability was found to be ICC=0.942 for total score, 0.902 for constant pain subscale, and 0.945 for intermittent pain subscale. Internal consistency was tested using Cronbach's alpha and was found to be 0.970 for total score, 0.948 for constant pain subscale, and 0.972 for intermittent pain subscale. For criterion validity, the correlation between the total score of ICOAP-TR and WOMAC pain subscale was r=0.779 (p<0.05), and correlation between total score of ICOAP-TR and VAS was r=0.570 (p<0.05). The ICOAP-TR is a reliable and valid instrument to be used with patients with knee OA.
Peterson, Eleanor B; Calhoun, Aaron W; Rider, Elizabeth A
2014-09-01
With increased recognition of the importance of sound communication skills and communication skills education, reliable assessment tools are essential. This study reports on the psychometric properties of an assessment tool based on the Kalamazoo Consensus Statement Essential Elements Communication Checklist. The Gap-Kalamazoo Communication Skills Assessment Form (GKCSAF), a modified version of an existing communication skills assessment tool, the Kalamazoo Essential Elements Communication Checklist-Adapted, was used to assess learners in a multidisciplinary, simulation-based communication skills educational program using multiple raters. 118 simulated conversations were available for analysis. Internal consistency and inter-rater reliability were determined by calculating a Cronbach's alpha score and intra-class correlation coefficients (ICC), respectively. The GKCSAF demonstrated high internal consistency with a Cronbach's alpha score of 0.844 (faculty raters) and 0.880 (peer observer raters), and high inter-rater reliability with an ICC of 0.830 (faculty raters) and 0.89 (peer observer raters). The Gap-Kalamazoo Communication Skills Assessment Form is a reliable method of assessing the communication skills of multidisciplinary learners using multi-rater methods within the learning environment. The Gap-Kalamazoo Communication Skills Assessment Form can be used by educational programs that wish to implement a reliable assessment and feedback system for a variety of learners. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Home Healthcare Nurses' Job Satisfaction Scale: refinement and psychometric testing.
Ellenbecker, Carol H; Byleckie, James J
2005-10-01
This paper describes a study to further develop and test the psychometric properties of the Home Healthcare Nurses' Job Satisfaction Scale, including reliability and construct and criterion validity. Numerous scales have been developed to measure nurses' job satisfaction. Only one, the Home Healthcare Nurses' Job Satisfaction Scale, has been designed specifically to measure job satisfaction of home healthcare nurses. The Home Healthcare Nurses' Job Satisfaction Scale is based on a theoretical model that integrates the findings of empirical research related to job satisfaction. A convenience sample of 340 home healthcare nurses completed the Home Healthcare Nurses' Job Satisfaction Scale and the Mueller and McCloskey Satisfaction Scale, which was used to test criterion validity. Factor analysis was used for testing and refinement of the theory-based assignment of items to constructs. Reliability was assessed by Cronbach's alpha internal consistency reliability coefficients. The data were collected in 2003. Nine factors contributing to home healthcare nurses' job satisfaction emerged from the factor analysis and were strongly supported by the underlying theory. Factor loadings were all above 0.4. Cronbach's alpha coefficients for each of the nine subscales ranged from 0.64 to 0.83; the alpha for the global scale was 0.89. The correlations between the Home Healthcare Nurses' Job Satisfaction Scale and Mueller and McCloskey Satisfaction Scale was 0.79, indicating good criterion-related validity. The Home Healthcare Nurses' Job Satisfaction Scale has potential as a reliable and valid scale for measurement of job satisfaction of home healthcare nurses.
Uchmanowicz, Izabella; Wleklik, Marta
According to the guidelines of the European Society of Cardiology, education in heart failure (HF) should focus on preparing the patient for self-control and self-care. Only systematic assessment of the level of self-care in HF enables the optimisation and adaptation of education to meet the patient's needs. The research tool commonly used to assess self-care in HF patients is the nine-item European Heart Failure Self-care Behaviour Scale (9-EHFScBS). To test the reliability of the Polish version of the 9-EHFScBS. A standard guideline was used for the translation and cultural adaptation of the English version of the 9-EHFScBS into Polish. The study included 110 Polish patients (mean age 66.0 ± 11.4 years); 51 men and 59 women. Cronbach's alpha was used for the analysis of the internal consistency of the 9-EHFScBS. The mean overall level of self-care in the study group was 27.65 points (SD 7.13 points). Good or satisfactory levels of self-care were found in three out of nine analysed variables. The reliability of the self-care scale was alpha = 0.787. The value of Cronbach's alpha after the exclusion of individual statements ranged from 0.75 to 0.81. The 9-EHFScBS questionnaire is a reliable research tool in assessing the level of self-care among patients with HF in the Polish population.
Development and Adaptation of Iranian Youth Reproductive Health Questionnaire
Mousavi, Abbas; Keramat, Afsaneh; Vakilian, Katayon; Esmaeili Vardanjani, Safar Ali
2013-01-01
Iran is a young country, and sexual behavior is shaped in this period. This research aimed to provide an assessment tool to evaluate Iranian youth reproductive health. This multistage research was conducted to design a valid questionnaire in the domains of knowledge, attitude, and behavior of the youth in order to evaluate behavior change programs. For this reason, after conducting a careful literature review and a qualitative research, the questionnaire was prepared. Forward and backward translations were performed. Professionals and students were used to make sure of qualitative and quantitative content and face validity. After conducting the pilot study on 100 students and eliminating defects in performance, reliability was evaluated by test-retest and Cronbach's alpha was calculated. In this study, out of 268 questions, 198 were retained after face and content validity. Self-efficacy of communication with father and mother, self-efficacy of condom use, and self-efficacy of abstinence had the highest Cronbach's alpha. Moreover, communication with parents regarding reproductive health issues and attitude to abstinence had a high Cronbach's alpha, as well. It seems to be a good instrument for assessment of Iranian reproductive health, and we are going to assess youth reproductive health in the future. PMID:23984084
Development and Initial Validation of the Environmental Restriction Questionnaire (ERQ)
ERIC Educational Resources Information Center
Rosenberg, Limor; Ratzon, Nava Z.; Jarus, Tal; Bart, Orit
2010-01-01
The purpose of this manuscript was to develop and test the psychometric properties of the Environmental Restriction Questionnaire (ERQ) a parent-reported questionnaire for measuring perceived environmental restrictions for young children participation. Reliability and homogeneity were tested by Cronbach's alpha and inter-item correlations.…
Psychometric Properties of the Adolescent Health Concern Inventory: The Persian Version
Baheiraei, Azam; Ahmadi, Fazlollah; Foroushani, Abbas Rahimi; Ghofranipour, Fazlollah; Weiler, Robert M
2013-01-01
Objective It is important to consider the health concerns of adolescents before developing and implementing public health promotion or health education curriculum programs aimed at ameliorating priority health problems experienced by adolescents. The aim of this study was to test the psychometric properties of the original Adolescent Health Concern Inventory (AHCI) for use with an Iranian population. Methods This was a methodological study in which 50 adolescents with age range of 14-18 years were selected using convenience sampling. The translation and cultural adaptation process of The AHCI followed recognized and established guidelines. The face and content validity was established by analyzing feedback solicited from teenagers and professionals with expertise in health, sociology and psychology. Reliability was examined using test-retest and Cronbach's alpha for internal consistency reliability. Kappa and McNemar tests were used to examine test-retest reliability for each item. Results Minor cultural differences were identified and resolved during the translation process and determining the validity of the checklist. Results from Kappa and McNemar tests indicate a high degree of test-retest reliability. Internal consistency reliability as measured by Cronbach's alpha for the subscales were between 0.68 and 0.87 with total instrument reliability of 0.96 indicating considerable overall reliability. Conclusion The Persian version of the AHCI appears valid and reliable. Hence, it can be used for filling a gap in identifying the adolescents’ health concerns in the research and community settings and school health education programs in Iran to design appropriate interventions. PMID:23682249
Uysal, Hilal; Ozcan, Şeyda
2011-06-01
Many new measuring devices have been developed so that broader psychometric measurements in the coronary artery disease, disease-specific health status measurements, and identification of the broader quality of life can be performed in the recent years. The study was intended to determine whether, and to what extent, MIDAS is a valid and reliable measurement to the patients suffering from myocardial infarction for the first time in Turkey. The research was conducted with the patients hospitalized and treated with myocardial infarction in the cardiology departments of 2 hospitals in Istanbul, Turkey, between 2007 and 2008. Psychometric evaluations of TR-MIDAS were used for validity studies; language validity, content validity, construct validity were examined. For reliability studies; the tool's internal consistency reliability, Cronbach's alpha reliability coefficient, and test-retest reliability were completed. The instrument's content validity index was determined to be "0.95". Principal component analysis revealed six factors with an eigenvalue >1.5. Cronbach's alpha was found to be 0.89 for total scale which was an acceptable value. The total's test-retest reliability was 0.51 (p<0.01). Data obtained at the end of the study supports that Turkish Myocardial Infarction Dimensional Assessment Scale is a valid and reliable instrument as a disease-specific scale to assess the patients' quality of life suffering from myocardial infarction in Turkey. Copyright © 2010 European Society of Cardiology. Published by Elsevier B.V. All rights reserved.
Gagnon, Susie; Gagnon, Marie-Pierre; Turcotte, Stéphane; Lapointe, Jean; Fleet, Richard; Côté, Mario; Beaupré, Pierre; Le Sage, Natalie; Émond, Marcel; Légaré, France
2014-01-01
Background Little is known about factors influencing professionals’ use of wikis. Objective We developed and validated two questionnaires to assess health care professionals’ intention to use wiki-based reminders for the management of trauma patients. Methods We developed questionnaires for emergency physicians (EPs) and allied health professions (AHPs) based on the Theory of Planned Behavior and adapted them to the salient beliefs of each, identified in an earlier study. Items measured demographics and direct and indirect theoretical constructs. We piloted the questionnaires with 2 focus groups (5 EPs and 5 AHPs) to identify problems of wording and length. Based on feedback, we adjusted the wording and combined certain items. A new convenience sample of 25 EPs and 26 AHPs then performed a test-retest of the questionnaires at a 2-week interval. We assessed internal consistency using Cronbach alpha coefficients and temporal stability of items with an agreement intraclass correlation coefficient (ICC). Results Five EPs and 5 AHPs (3 nurses, 1 respiratory therapist, and 1 pharmacist) formed 2 focus groups; 25 EPs and 26 AHPs (12 nurses, 7 respiratory therapists, and 7 pharmacists) completed the test and retest. The EP questionnaire test-retest scores for consistency (Cronbach alpha) and stability (ICC) were intention (test: Cronbach alpha=.94; retest: Cronbach alpha=.98; ICC=.89), attitude (.74, .72, .70), subjective norm (.79, .78, .75), perceived behavioral control (.67, .65, .66), attitudinal beliefs (.94, .86, .60), normative beliefs (.83, .87, .79), and control beliefs barriers (.58, .67, .78) and facilitators (.97, .85, .30). The AHP questionnaire scores for consistency and stability were: intention (test Cronbach alpha=.69, retest Cronbach alpha=.81, ICC=.48), attitude (.85, .87, .83), subjective norm (.47, .82, .62), perceived behavioral control (.55, .62, .60), attitudinal beliefs (.92, .91, .82), normative beliefs (.85, .90, .74), and control beliefs barriers (.58, .55, .66) and facilitators (.72, .94, –.05). To improve the psychometric properties of both questionnaires, we reformulated poorly consistent or unstable items. Conclusions Our new theory-based questionnaires to measure health care professionals’ intention to use wiki-based reminders have adequate validity and reliability for use in large surveys. In the long run, they can be used to develop a theory-based implementation intervention for a wiki promoting best practices in trauma care. PMID:25281856
Archambault, Patrick Michel; Gagnon, Susie; Gagnon, Marie-Pierre; Turcotte, Stéphane; Lapointe, Jean; Fleet, Richard; Côté, Mario; Beaupré, Pierre; Le Sage, Natalie; Emond, Marcel; Légaré, France
2014-10-03
Little is known about factors influencing professionals' use of wikis. We developed and validated two questionnaires to assess health care professionals' intention to use wiki-based reminders for the management of trauma patients. We developed questionnaires for emergency physicians (EPs) and allied health professions (AHPs) based on the Theory of Planned Behavior and adapted them to the salient beliefs of each, identified in an earlier study. Items measured demographics and direct and indirect theoretical constructs. We piloted the questionnaires with 2 focus groups (5 EPs and 5 AHPs) to identify problems of wording and length. Based on feedback, we adjusted the wording and combined certain items. A new convenience sample of 25 EPs and 26 AHPs then performed a test-retest of the questionnaires at a 2-week interval. We assessed internal consistency using Cronbach alpha coefficients and temporal stability of items with an agreement intraclass correlation coefficient (ICC). Five EPs and 5 AHPs (3 nurses, 1 respiratory therapist, and 1 pharmacist) formed 2 focus groups; 25 EPs and 26 AHPs (12 nurses, 7 respiratory therapists, and 7 pharmacists) completed the test and retest. The EP questionnaire test-retest scores for consistency (Cronbach alpha) and stability (ICC) were intention (test: Cronbach alpha=.94; retest: Cronbach alpha=.98; ICC=.89), attitude (.74, .72, .70), subjective norm (.79, .78, .75), perceived behavioral control (.67, .65, .66), attitudinal beliefs (.94, .86, .60), normative beliefs (.83, .87, .79), and control beliefs barriers (.58, .67, .78) and facilitators (.97, .85, .30). The AHP questionnaire scores for consistency and stability were: intention (test Cronbach alpha=.69, retest Cronbach alpha=.81, ICC=.48), attitude (.85, .87, .83), subjective norm (.47, .82, .62), perceived behavioral control (.55, .62, .60), attitudinal beliefs (.92, .91, .82), normative beliefs (.85, .90, .74), and control beliefs barriers (.58, .55, .66) and facilitators (.72, .94, -.05). To improve the psychometric properties of both questionnaires, we reformulated poorly consistent or unstable items. Our new theory-based questionnaires to measure health care professionals' intention to use wiki-based reminders have adequate validity and reliability for use in large surveys. In the long run, they can be used to develop a theory-based implementation intervention for a wiki promoting best practices in trauma care.
Sierpińska, Lidia
2013-09-01
The Authentic Leadership Questionnaire (ALQ) is a standardized research instrument for the evaluation of individual elements of leader's conduct which contribute to the authentic leadership. The application of this questionnaire in Polish conditions required to carry out the validation process. The aim of the study was to evaluate of validity and reliability of the Polish version of the American research instrument for the needs of evaluation of authenticity of leadership of the nursing management in Polish hospitals. The study covered 286 nurses (143 head nurses and 143 of their subordinates) employed in 45 hospitals in Poland. Theoretical validity of the instrument was evaluated using Fisher's transformation (r-Person correlation coefficient), while the criterion validity of the ALQ was evaluated using rho-Spearman correlation coefficient and the BOHIPSZO questionnaire. The reliability of the ALQ was assessed by means of the Cronbach-alpha coefficient. The ALQ questionnaire applied for the evaluation of authenticity of leadership of the nursing management in Polish hospital wards shows an acceptable theoretical and criterion validity and reliability (Cronbach-alpha coefficient 0.80). The Polish version of the ALQ is valid and reliable, and may be applied in studies concerning the evaluation of authenticity of leadership of the nursing management in Polish hospital wards.
Martignon, Stefania; Bautista-Mendoza, Gloria; González-Carrera, María; Lafaurie-Villamil, Gloria; Morales, Veicy; Santamaría, Ruth
2008-01-01
Designing three instruments for evaluating oral health knowledge, attitudes and practice in parents/caregivers of low social-economic status 0-5 year-olds. Evaluating the instruments' reliability in terms of internal consistency and analysing items. Three instruments were constructed for evaluating low social-economic status 0-5 year-olds' parents/caregivers' oral health knowledge, attitudes and practice in the municipality of Usaquén , Bogotá , Colombia . 47 parents/caregivers were given a test establishing the instrument's reliability in terms of internal consistency and the adults' level of knowledge, attitudes and practice. A sub-sample was qualitatively analysed (content verification and understanding). Reliability was evaluated using Cronbach's alpha coefficient. Items were analysed for improving constructing and understanding the questions, taking four criteria into account: corrected homogeneity index (CHI), response trend, correlation between items and qualitative analysis. Cronbach's alpha coefficient for knowledge, attitudes and practice was 0,82, 0,80 and 0,62, respectively. Participants' level of knowledge, attitudes and practice was acceptable (60 %, 55 % and 91 %, respectively). This study found two out of the three evaluated instruments to be reliable (knowledge and attitudes); all three of them were then redesigned. The resulting instruments represent a valuable tool which can be used in future studies for describing and evaluating preventative programmes.
[New questionnaire to assess self-efficacy toward physical activity in children].
Aedo, Angeles; Avila, Héctor
2009-10-01
To design a questionnaire for assessment of self-efficacy toward physical activity in school children, as well as to measure its construct validity, test-retest reliability, and internal consistency. A four-stage multimethod approach was used: (1) bibliographic research followed by exploratory study and the formulation of questions and responses based on a dichotomous scale of 14 items; (2) validation of the content by a panel of experts; (3) application of the preliminary version of the questionnaire to a sample of 900 school-aged children in Mexico City; and (4) determination of the construct validity, test-retest reliability, and internal consistency (Cronbach's alpha). Three factors were identified that explain 64.15% of the variance: the search for positive alternatives to physical activity, ability to deal with possible barriers to exercising, and expectations of skill or competence. The model was validated using the goodness of fit, and the result of 65% less than 0.05 indicated that the estimated factor model fit the data. Cronbach's consistency alpha was 0.733; test-retest reliability was 0.867. The scale designed has adequate reliability and validity. These results are a good indicator of self-efficacy toward physical activity in school children, which is important when developing programs intended to promote such behavior in this age group.
Validity and reliability of the Self-Reported Physical Fitness (SRFit) survey.
Keith, NiCole R; Clark, Daniel O; Stump, Timothy E; Miller, Douglas K; Callahan, Christopher M
2014-05-01
An accurate physical fitness survey could be useful in research and clinical care. To estimate the validity and reliability of a Self-Reported Fitness (SRFit) survey; an instrument that estimates muscular fitness, flexibility, cardiovascular endurance, BMI, and body composition (BC) in adults ≥ 40 years of age. 201 participants completed the SF-36 Physical Function Subscale, International Physical Activity Questionnaire (IPAQ), Older Adults' Desire for Physical Competence Scale (Rejeski), the SRFit survey, and the Rikli and Jones Senior Fitness Test. BC, height and weight were measured. SRFit survey items described BC, BMI, and Senior Fitness Test movements. Correlations between the Senior Fitness Test and the SRFit survey assessed concurrent validity. Cronbach's Alpha measured internal consistency within each SRFit domain. SRFit domain scores were compared with SF-36, IPAQ, and Rejeski survey scores to assess construct validity. Intraclass correlations evaluated test-retest reliability. Correlations between SRFit and the Senior Fitness Test domains ranged from 0.35 to 0.79. Cronbach's Alpha scores were .75 to .85. Correlations between SRFit and other survey scores were -0.23 to 0.72 and in the expected direction. Intraclass correlation coefficients were 0.79 to 0.93. All P-values were 0.001. Initial evaluation supports the SRFit survey's validity and reliability.
Roque, Fátima; Soares, Sara; Breitenfeld, Luiza; Gonzalez-Gonzalez, Cristian; Figueiras, Adolfo; Herdeiro, Maria Teresa
2014-01-01
To develop and evaluate the reliability of a self-administered questionnaire designed to assess the attitudes and knowledge of community pharmacists in Portugal about microbial resistance and the antibiotic dispensing process. This study was divided into the following three stages: (1) design of the questionnaire, which included a literature review and a qualitative study with focus-group sessions; (2) assessment of face and content validity, using a panel of experts and a pre-test of community pharmacists; and, (3) pilot study and reliability analysis, which included a test-retest study covering fifty practising pharmacists based at community pharmacies in five districts situated in Northern Portugal. Questionnaire reproducibility was quantified using the intraclass correlation coefficient (ICC; 95% confidence interval) computed by means of one-way analysis of variance (ANOVA). Internal consistency was evaluated using Cronbach's alpha. The correlation coefficients were fair to good (ICC>0.4) for all statements (scale-items) regarding knowledge of and attitudes to antibiotic resistance, and ranged from fair to good to excellent for statements about situations in which pharmacists acknowledged that antibiotics were sometimes dispensed without a medical prescription (ICC>0.8). Cronbach's alpha for this section was 0.716. The questionnaire designed in this study is valid and reliable in terms of content validity, face validity and reproducibility.
Malec, James F; Kragness, Miriam; Evans, Randall W; Finlay, Karen L; Kent, Ann; Lezak, Muriel D
2003-01-01
To evaluate the internal consistency of the Mayo-Portland Adaptability Inventory (MPAI), further refine the instrument, and provide reference data based on a large, geographically diverse sample of persons with acquired brain injury (ABI). 386 persons, most with moderate to severe ABI. Outpatient, community-based, and residential rehabilitation facilities for persons with ABI located in the United States: West, Midwest, and Southeast. Rasch, item cluster, principal components, and traditional psychometric analyses for internal consistency of MPAI data and subscales. With rescoring of rating scales for 4 items, a 29-item version of the MPAI showed satisfactory internal consistency by Rasch (Person Reliability=.88; Item Reliability=.99) and traditional psychometric indicators (Cronbach's alpha=.89). Three rationally derived subscales for Ability, Activity, and Participation demonstrated psychometric properties that were equivalent to subscales derived empirically through item cluster and factor analyses. For the 3 subscales, Person Reliability ranged from.78 to.79; Item Reliability, from.98 to.99; and Cronbach's alpha, from.76 to.83. Subscales correlated moderately (Pearson r =.49-.65) with each other and strongly with the overall scale (Pearson r=.82-.86). Outcome after ABI is represented by the unitary dimension described by the MPAI. MPAI subscales further define regions of this dimension that may be useful for evaluation of clinical cases and program evaluation.
Psychometric Analysis of Role Conflict and Ambiguity Scales in Academia
ERIC Educational Resources Information Center
Khan, Anwar; Yusoff, Rosman Bin Md.; Khan, Muhammad Muddassar; Yasir, Muhammad; Khan, Faisal
2014-01-01
A comprehensive Psychometric Analysis of Rizzo et al.'s (1970) Role Conflict & Ambiguity (RCA) scales were performed after its distribution among 600 academic staff working in six universities of Pakistan. The reliability analysis includes calculation of Cronbach Alpha Coefficients and Inter-Items statistics, whereas validity was determined by…
(De)Motivation in Preparatory EFL Classrooms
ERIC Educational Resources Information Center
Vefali, Gülsen Musayeva; Ayan, Hatice Ç.
2015-01-01
This survey study aimed to explore EFL learners' (de)motivation in the preparatory classes at a tertiary institution in Northern Cyprus. It administered questionnaires to 105 preparatory learners and 30 language teachers. The statistical analysis revealed the Cronbach's alpha reliability coefficient of 0.88 for the Learners' version, and 0.89 for…
Lim, Renly; Liong, Men Long; Khan, Nurzalina Abdul Karim; Yuen, Kah Hay
2017-02-17
There is currently no published information on the validity and reliability of the Golombok Rust Inventory of Sexual Satisfaction in the Asian population, specifically in patients with stress urinary incontinence, which limits its use in this region. Our study aimed to evaluate the psychometric properties of this questionnaire in the Malaysian population. Ten couples were recruited for the pilot testing. The agreement between the English and Chinese or Malay versions were tested using the intraclass correlation coefficients, with results of more than 0.80 for all subscales and overall scores indicating good agreement. Sixty-six couples were included in the subsequent phase. The following data are presented in the order of English, Chinese, and Malay. Cronbach's alphas for the male total score were 0.82, 0.88, and 0.95. For the female total score, Cronbach's alphas were 0.76, 0.78, and 0.88. Intraclass correlation coefficients for the male total score were 0.93, 0.94, and 0.99, while intraclass correlation coefficients for the female total score were 0.89, 0.86, and 0.88. In conclusion, the English, Chinese, and Malay versions each proved to be valid and reliable in our Malaysian population.
Validation of general job satisfaction in the Korean Labor and Income Panel Study.
Park, Shin Goo; Hwang, Sang Hee
2017-01-01
The purpose of this study is to assess the validity and reliability of general job satisfaction (JS) in the Korean Labor and Income Panel Study (KLIPS). We used the data from the 17th wave (2014) of the nationwide KLIPS, which selected a representative panel sample of Korean households and individuals aged 15 or older residing in urban areas. We included in this study 7679 employed subjects (4529 males and 3150 females). The general JS instrument consisted of five items rated on a scale from 1 (strongly disagree) to 5 (strongly agree). The general JS reliability was assessed using the corrected item-total correlation and Cronbach's alpha coefficient. The validity of general JS was assessed using confirmatory factor analysis (CFA) and Pearson's correlation. The corrected item-total correlations ranged from 0.736 to 0.837. Therefore, no items were removed. Cronbach's alpha for general JS was 0.925, indicating excellent internal consistency. The CFA of the general JS model showed a good fit. Pearson's correlation coefficients for convergent validity showed moderate or strong correlations. The results obtained in our study confirm the validity and reliability of general JS.
Watson, Paul Barry; Seaton, Philippa; Sims, Deborah; Jamieson, Isabel; Mountier, Jane; Whittle, Rose; Saarikoski, Mikko
2014-01-01
The Clinical Learning Environment, Supervision and Nurse Teacher (CLES+T) scale measures student nurses' perceptions of clinical learning environments. This study evaluates the construct validity and internal reliability of the CLES+T in hospital settings in New Zealand. Comparisons are made between New Zealand and Finnish data. The CLES+T scale was completed by 416 Bachelor of Nursing students following hospital clinical placements between October 2008 and December 2009. Construct validity and internal reliability were assessed using exploratory factor analysis and Cronbach's alpha. Exploratory factor analysis supports 4 factors. Cronbach's alpha ranged from .82 to .93. All items except 1 loaded on the same factors found in unpublished Finnish data. The first factor combined 2 previous components from the published Finnish component analysis and was renamed: connecting with, and learning in, communities of clinical practice. The remaining 3 factors (Nurse teacher, Supervisory relationship, and Leadership style of the manager) corresponded to previous components and their conceptualizations. The CLES+T has good internal reliability and a consistent factor structure across samples. The consistency across international samples supports faculties and hospitals using the CLES+T to benchmark the quality of clinical learning environments provided to students.
[Balanced scorecard for performance measurement of a nursing organization in a Korean hospital].
Hong, Yoonmi; Hwang, Kyung Ja; Kim, Mi Ja; Park, Chang Gi
2008-02-01
The purpose of this study was to develop a balanced scorecard (BSC) for performance measurement of a Korean hospital nursing organization and to evaluate the validity and reliability of performance measurement indicators. Two hundred fifty-nine nurses in a Korean hospital participated in a survey questionnaire that included 29-item performance evaluation indicators developed by investigators of this study based on the Kaplan and Norton's BSC (1992). Cronbach's alpha was used to test the reliability of the BSC. Exploratory and confirmatory factor analysis with a structure equation model (SEM) was applied to assess the construct validity of the BSC. Cronbach's alpha of 29 items was .948. Factor analysis of the BSC showed 5 principal components (eigen value >1.0) which explained 62.7% of the total variance, and it included a new one, community service. The SEM analysis results showed that 5 components were significant for the hospital BSC tool. High degree of reliability and validity of this BSC suggests that it may be used for performance measurements of a Korean hospital nursing organization. Future studies may consider including a balanced number of nurse managers and staff nurses in the study. Further data analysis on the relationships among factors is recommended.
Lang, Jonas W B
2014-07-01
The measurement of implicit or unconscious motives using the picture story exercise (PSE) has long been a target of debate in the psychological literature. Most debates have centered on the apparent paradox that PSE measures of implicit motives typically show low internal consistency reliability on common indices like Cronbach's alpha but nevertheless predict behavioral outcomes. I describe a dynamic Thurstonian item response theory (IRT) model that builds on dynamic system theories of motivation, theorizing on the PSE response process, and recent advancements in Thurstonian IRT modeling of choice data. To assess the models' capability to explain the internal consistency paradox, I first fitted the model to archival data (Gurin, Veroff, & Feld, 1957) and then simulated data based on bias-corrected model estimates from the real data. Simulation results revealed that the average squared correlation reliability for the motives in the Thurstonian IRT model was .74 and that Cronbach's alpha values were similar to the real data (<.35). These findings suggest that PSE motive measures have long been reliable and increase the scientific value of extant evidence from motivational research using PSE motive measures. (c) 2014 APA, all rights reserved.
Stucki, G; Sangha, O; Stucki, S; Michel, B A; Tyndall, A; Dick, W; Theiler, R
1998-03-01
To compare the metric properties and validity of German versions of the WOMAC (Western Ontario and McMaster Universities) and a self-administered questionnaire-format of the Lequesne-Algofunctional-Index in patients with osteoarthritis (OA) of the lower extremities. Cross-sectional analysis of the instruments' internal consistency (Cronbach's coefficient alpha) and construct validity (correlation with radiological OA-severity and limitation in range-of-motion) in ambulatory patients and patients before hip arthroplasty. Test-retest reliability was assessed on a subsample after 10 days. Data from 51 patients out of 91 contacted could be analyzed. Twenty-nine patients had knee and 22 patients had hip OA. Both the WOMAC and Lequesne OA-indices and their scales or sections had a satisfactory test-retest reliability (Intraclass correlation coefficient 0.43-0.96). All scales of the WOMAC were internally consistent (Cronbach's coefficient alpha 0.81-0.96) and associated with radiological OA-severity and joint range of motion. However, only the function but not the symptom sections (Cronbach's coefficient alpha knee: 0.55; hip: 0.63) of the self-administered Lequesne OA index were internally consistent for both, patients with knee and hip OA. Also, the symptom components were not or only weakly associated with radiological OA-severity and joint range of motion. Although our results are based on a German version using a self-report format we may caution using the self-administered Lequesne OA index without prior testing of its metric properties and validity.
Mousavian, Alireza; Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Omidi-Kashani, Farzad; Kachooei, Amir Reza
2015-12-01
In this study, we aimed to translate and test the validity and reliablity of the Persian version of the Manchester-Oxford Foot Questionnaire in foot and ankle patients. We translated the Manchester-Oxford Foot Questionnaire to Persian language according to the accepted guidelines, then assessed the psychometric properties including the validity and reliability on 308 patients with long-standing foot and ankle problems. To test the reliability, we calculated the intra-class correlation coefficient (ICC) for test-retest reliability and measured Cronbach's alpha to test the internal consistency. To test the construct validity of the Manchester-Oxford Foot Questionnaire we also administered the Short-Form 36 to patients. Construct validity was supported by significant correlation with SF36 subscales except for pain subscale of the persian MOXFQ with mental health of the SF36 (r=0.207). Intraclass correlation coefficient was 0.79 for the total MOXFQ and ranged from 0.83 to 0.89 for the three subscales. Cronbach's alpha for pain, walking/standing, and social interaction was 0.86, 0.88, and 0.89, respectively, and was 0.79 for the total MOXFQ showing good internal consistency in each domain. The Persian Manchester-Oxford Foot Questionnaire health scoring system is a valid and reliable patient-reported instrument for foot and ankle problems. Copyright © 2015. Published by Elsevier Ltd.
Validation of a method for assessing resident physicians' quality improvement proposals.
Leenstra, James L; Beckman, Thomas J; Reed, Darcy A; Mundell, William C; Thomas, Kris G; Krajicek, Bryan J; Cha, Stephen S; Kolars, Joseph C; McDonald, Furman S
2007-09-01
Residency programs involve trainees in quality improvement (QI) projects to evaluate competency in systems-based practice and practice-based learning and improvement. Valid approaches to assess QI proposals are lacking. We developed an instrument for assessing resident QI proposals--the Quality Improvement Proposal Assessment Tool (QIPAT-7)-and determined its validity and reliability. QIPAT-7 content was initially obtained from a national panel of QI experts. Through an iterative process, the instrument was refined, pilot-tested, and revised. Seven raters used the instrument to assess 45 resident QI proposals. Principal factor analysis was used to explore the dimensionality of instrument scores. Cronbach's alpha and intraclass correlations were calculated to determine internal consistency and interrater reliability, respectively. QIPAT-7 items comprised a single factor (eigenvalue = 3.4) suggesting a single assessment dimension. Interrater reliability for each item (range 0.79 to 0.93) and internal consistency reliability among the items (Cronbach's alpha = 0.87) were high. This method for assessing resident physician QI proposals is supported by content and internal structure validity evidence. QIPAT-7 is a useful tool for assessing resident QI proposals. Future research should determine the reliability of QIPAT-7 scores in other residency and fellowship training programs. Correlations should also be made between assessment scores and criteria for QI proposal success such as implementation of QI proposals, resident scholarly productivity, and improved patient outcomes.
Monzani, D; Genovese, E; Marrara, A; Gherpelli, C; Pingani, L; Forghieri, M; Rigatelli, M; Guadagnin, T; Arslan, E
2008-06-01
The aim of this study was to determine the validity of the Italian translation of the Tinnitus Handicap Inventory (THI) by Newman et al. in order to make this self-report measure of perceived tinnitus handicap available both for clinical and research purposes in our country and to contribute to its cross-cultural validation as a self-report measure of perceived severity of tinnitus. The Italian translation of the Tinnitus Handicap Inventory (THI) was administered to 100 outpatients suffering from chronic tinnitus, aged between 20 and 82 years, who attended the audiological tertiary centres of the University Hospital of Modena and the Regional Hospital of Treviso. No segregation of cases was made on audiometric results; patients suffering from vertigo and neurological diseases were excluded. Pyschoacoustic characteristics of tinnitus (loudness and pitch) were determined and all patients also completed the MOS 36-Item Short Form Health Survey to assess self-perceived quality of life and the Hospital Anxiety and Depression Scale as a measure of self-perceived levels of anxiety and depression. The THI-I showed a robust internal consistency reliability (Cronbach's alpha = 0.91) that was only slightly lower than the original version (Tinnitus Handicap Inventory-US; Cronbach's alpha = 0.93) and its Danish (Cronbach's alpha = 0.93) and Portuguese (Cronbach's alpha = 0.94) translations. Also its two subscales (Functional and Emotional) showed a good internal consistency reliability (Cronbach's alpha = 0.85 and 0.86, respectively). On the other hand, the Catastrophic subscale showed an unacceptable internal consistency reliability as it is too short in length (5 items). A confirmatory factor analysis failed to demonstrate that the 3 subscales of the THI-I correspond to 3 different factors. Close correlations were found between the total score of the Italian translation of the Tinnitus Handicap Inventory and all the subscales of the MOS 36-Item Short Form Health Survey (SF-36) and the Hospital Anxiety and Depression Scale scores indicating a good construct validity. Moreover, these statistically significant correlations (p < 0.005) confirmed that the self-report tinnitus handicap is largely related to psychological distress and a deterioration in the quality of life. On the other hand, it was confirmed that the tinnitus perceived handicap is totally independent (p > 0.05) from its audiometrically-derived measures of loudness and pitch thus supporting previous studies that focused on the importance of non-auditory factors, namely somatic attention, psychological distress and coping strategies, in the generation of tinnitus annoyance. Finally the results of the present study suggest that the THI-I maintains its original validity and should be incorporated, together with other adequate psychometric questionnaires, in the audiological examination of patients suffering from tinnitus and that psychiatric counselling should be recommended for the suspected co-morbidity between tinnitus annoyance and psychological distress.
Nia, Hamid Sharif; Sharif, Saeed Pahlevan; Froelicher, Erika Sivarajan; Boyle, Christopher; Goudarzian, Amir Hossein; Yaghoobzadeh, Ameneh; Oskouie, Fatemeh
2018-04-01
The aim of this study was to validate a Persian version of the Cardiac Depression Scale (CDS) in Iranian patients with acute myocardial infarction (AMI). The CDS was forward translated from English into Persian and back-translated to English. Validity was assessed using face, content, and construct validity. Also Cronbach's alpha (α), theta (), and McDonald's omega coefficient were used to evaluate the reliability. Construct validity of the scale showed two factors with eigenvalues greater than one. The Cronbach's α, , McDonald's omega, and construct reliability were greater than .70. The Persian version of the CDS has a two-factor structure (i.e., death anxiety and life satisfaction) and has acceptable reliability and validity. Therefore, the validated instrument can be used in future studies to assess depression in patients with AMI in Iranians.
ULUS, Yasemin; TERZİ, Yüksel; ZAHİROĞLU, Yeliz; KESMEN, Hakan; FARİSOĞULLARI, Bayram; AKYOL, Yeşim; BİLGİCİ, Ayhan; KURU, Ömer
2016-01-01
Objectives This study aims to evaluate the reliability and validity of the Turkish language version of VITACORA-19 (psoriatic arthritis quality of life questionnaire) in patients with psoriatic arthritis. Patients and methods The Turkish version of VITACORA-19 questionnaire was obtained after a translation and back translation process. The study sample included 61 PsA patients (22 males, 39 females; mean age 46.5±12.2 years; range 19 to 71 years). To assess the test-retest reliability of the Turkish VITACORA-19, the questionnaire was reapplied 10 to 15 days after the first interview (interclass correlation coefficient). Cronbach’s alpha (a) was used to evaluate the internal consistency. VITACORA-19 was compared with visual analog scale for physician and patient global assessments, the Health Assessment Questionnaire, and Nottingham Health Profile for construct validity. The internal structure of VITACORA-19 was examined by factor analysis. Results The individual item intraclass correlation coefficient ranged from 0.77 to 0.98 and Cronbach's alpha ranged from 0.77 to 0.98. The Cronbach's alpha value for whole scale was determined as 0.96. The Kaiser-Meyer-Olkin measure of sampling adequacy was 0.90, and Bartlett's test of sphericity had a p<0.001. Turkish VITACORA-19 total scores were correlated negatively with Health Assessment Questionnaire, visual analog scale for pain, and Nottingham Health Profile subgroups, and positively with physician and patient global assessments (p<0.01). Conclusion Turkish version of VITACORA-19 questionnaire is a reliable and valid measure for health-related quality of life in Turkish patients with psoriatic arthritis. PMID:29900999
Tam, Wilson; Keung, Vera; Lee, Albert; Lo, Kenneth; Cheung, Calvin
2014-11-21
Childhood obesity is a major public health issue in many countries, including China. The importance of parenting relative to the healthy development of children requires the development of instruments for assessing parental influence on child dietary pattern. This study aimed to confirm the internal reliability and validity of a self-report measure on parental feeding styles, including emotional feeding, instrumental feeding, prompting or encouragement to eat, and control over eating. A 27-item parental feeding style questionnaire (PFSQ) was translated into Chinese and then translated back into English to verify consistency. The questionnaire was then used to conduct a cross-sectional survey on the parents of Hong Kong preschoolers. The internal reliability and validity of the questionnaire were examined by Cronbach's alpha and exploratory factor analysis, respectively. 4,553 completed questionnaires were received. Cronbach's alpha of subscales ranged from 0.63 to 0.81, and the overall reliability was good (alpha = 0.75). The factor structure of this questionnaire was similar to that of the original and Turkish versions. One-factor structure was identified for emotional feeding, instrumental feeding (four items), and prompting or encouragement to eat, whereas a two-factor structure was revealed for control over eating. The Chinese version of the PFSQ has good reliability and validity in assessing parental feeding styles in Hong Kong. Researchers can use this instrument to improve their understanding on how parental feeding styles may affect the dietary patterns and ultimately the weight statuses of children among Chinese-speaking populations across different countries.
Omotosho, Tola B; Hardart, Anne; Rogers, Rebecca G; Schaffer, Joseph I; Kobak, William H; Romero, Audrey A
2009-06-01
The purpose of this study is to validate Spanish versions of the Pelvic Floor Distress Inventory (PFDI) and Pelvic Floor Impact Questionnaire (PFIQ). Spanish versions were developed using back translation and validation was performed by randomizing bilingual women to complete the Spanish or English versions of the questionnaires first. Weighted kappa statistics assessed agreement for individual questions; interclass correlation coefficients (ICC) compared primary and subscale scores. Cronbach's alpha assessed internal consistency of Spanish versions. To detect a 2.7 point difference in scores with 80% power and alpha of 0.05, 44 bilingual subjects were required. Individual questions showed good to excellent agreement (kappa > 0.6) for all but eight questions on the PFIQ. ICCs of primary and subscale scores for both questionnaires showed excellent agreement. (All ICC > 0.79). All Cronbach's alpha values were excellent (>0.84) for the primary scales of both questionnaires. Valid and reliable Spanish versions of the PFIQ and PFDI have been developed.
Majstorovic, M; Veerkamp, J S; Skrinjaric, I
2003-12-01
The aim of the study was to evaluate reliability and validity of different questionnaires and predict related causes, as concomitant factors in assessing different aspects of children's dental anxiety. Children were interviewed on dental anxiety, dispositional risk factors and satisfaction with the dentist after dental treatment had been accomplished. Parents were interviewed on dental anxiety as well. The study population included 165 children (91 boys) aged 5 to 15 years, referred to a university dental clinic by general dental practitioners because of a history of fear and uncooperative behaviour during previous dental visits. Children were treated by two dentists, both experienced in treating fearful children. Statistical analysis was performed in Statistics for Windows, Release 5.5 and Release 7.5. Pearson's correlation coefficients were calculated for validity and Cronbach alpha for reliability of the measures. Spearman Brown prophecy formula was used for correction of the alpha scores. Results The children's total average CFSS-DS score was 27.02, with no significant difference with respect to gender. The highest Cronbach alpha scores regarding reliability were obtained for the S-DAI, the CFSS-DS and the PDAS. Pearson's correlations regarding validity presented significant correlations between the CMFQ, the CDAS and the S-DAI, between the OAS, the CDAS and the S-DAI, as well as between the OAS and the DVSS-SV. Previous negative medical experience had significant influence on children's dental anxiety, supporting Rachman's conditioning theory. Anxious children were more likely to show behaviour problems (aggression) and more introvert in expressing their judgement regarding the dentist. Both the S-DAI and the CFSS-DS, which were standardized in the Croatian population sample, showed the highest reliability in assessment of children's dental anxiety.
Performance-Based Service Quality Model: An Empirical Study on Japanese Universities
ERIC Educational Resources Information Center
Sultan, Parves; Wong, Ho
2010-01-01
Purpose: This paper aims to develop and empirically test the performance-based higher education service quality model. Design/methodology/approach: The study develops 67-item instrument for measuring performance-based service quality with a particular focus on the higher education sector. Scale reliability is confirmed using the Cronbach's alpha.…
[Development and validation of the Korean patient safety culture scale for nursing homes].
Yoon, Sook Hee; Kim, Byungsoo; Kim, Se Young
2013-06-01
The purpose of this study was to develop a tool to evaluate patient safety culture in nursing homes and to test its validity and reliability. A preliminary tool was developed through interviews with focus group, content validity tests, and a pilot study. A nationwide survey was conducted from February to April, 2011, using self-report questionnaires. Participants were 982 employees in nursing homes. Data were analyzed using Cronbach's alpha, item analysis, factor analysis, and multitrait/multi-Item analysis. From the results of the analysis, 27 final items were selected from 49 items on the preliminary tool. Items with low correlation with total scale were excluded. The 4 factors sorted by factor analysis contributed 63.4% of the variance in the total scale. The factors were labeled as leadership, organizational system, working attitude, management practice. Cronbach's alpha for internal consistency was .95 and the range for the 4 factors was from .86 to .93. The results of this study indicate that the Korean Patient Safety Culture Scale has reliability and validity and is suitable for evaluation of patient safety culture in Korean nursing homes.
Al-Gamal, Ekhlas; Long, Tony; Livesley, Joan
2009-01-01
The purpose of this article is to report on the development and field testing for validity and reliability of a modified version of the Marwit and Meuser Caregiver Inventory (MM-CGI) for the assessment of anticipatory grief among Jordanian parents of children with cancer (the MM-CGI Childhood Cancer). In 2006, a 50-item MM-CGI Childhood Cancer was administered to 140 Jordanian parents living with a child with cancer. The Cronbach alpha coefficient for the total instrument was .95, and Cronbach alpha coefficients for each of the 3 subscales was .91 for personal sacrifice burden, .90 for heartfelt sadness and longing, and .86 for worry and felt isolation. The construct validity of this instrument was supported by demonstrating a significant and positive correlation with the Anticipatory Grief Scale. The MM-CGI Childhood Cancer demonstrated strong convergent validity and excellent internal consistency reliability. However, further testing with a larger sample to facilitate factor analysis is needed to complete the validation process.
Validation of the Walking Impairment Questionnaire for Spanish patients.
Lozano, Francisco S; March, José R; González-Porras, José R; Carrasco, Eduardo; Lobos, José M; Areitio-Aurtena, Alix
2013-09-01
The Walking Impairment Questionnaire (WIQ) is a short, easy to complete, disease-specific questionnaire to assess intermittent claudication. A Spanish version of the WIQ for Hispanic Americans has recently been validated in Texas, but it needs to be validated for European Spanish people. After translation and cultural adaptation of the WIQ, 920 patients with intermittent claudication (ankle brachial index < 0.9) completed two questionnaires (Spanish version of the WIQ and European Quality of Life 5 Dimension [EQ-5D]). The validity of the WIQ was determined by correlating WIQ and EQ-5D. Test-retest reliability and internal consistency were determined using the intra-class correlation coefficient (ICC) and Cronbach's alpha, respectively. The three domains of the WIQ were moderately correlated with the EQ-5D health outcome (r = 0.54 to 0.60; p < 0.001). Test-retest reliabilities ranged from ICC = 0.89 to 0.91 and internal consistency (Cronbach's alpha = 0.92) was high. The Spanish version of the WIQ for European Spanish patients was valid and reproducible, suggesting that it could be used in Spanish patients with intermittent claudication.
Leite, Priscilla Lourenço; Filomensky, Tatiana Zambrano; Black, Donald W; Silva, Adriana Cardoso
2014-08-01
The Yale-Brown Obsessive Compulsive Scale-Shopping Version (YBOCS-SV) is considered the gold standard in the assessment of shopping severity. It is designed to assess cognitions and behaviors relating to compulsive buying behavior. The present study aims to assess the validity of the Brazilian version of this scale. For the study, composed the sample 610 participants: 588 subjects of a general population and 22 compulsive buyers. Factorial analysis was performed to assess the relations and the correlation between the YBOCS-SV, the Compulsive Buying Scale (CBS), and Richmond Compulsive Buying Scale (RCBS), was assessed using Pearson coefficient, for study of convergent and divergent validity. Cronbach's alpha coefficients were used to assess internal consistency. The results show good to excellent psychometric parameters for the YBOCS-SV in its Brazilian version. With regard to correlations, the YBOCS-SV is inversely and proportionally correlated with CBS and the RCBS, indicating that the YBOCS-SV is an excellent instrument for screening compulsive buying. The YBOCS-SV presented high alpha coefficient of Cronbach's alpha (0.92), demonstrating good reliability. The Brazilian version of the YBOCS-SV is indicated to diagnose compulsive buying disorder, and likely use for the purposes intended in the Brazilian population. Copyright © 2014 Elsevier Inc. All rights reserved.
Kudubes, Asli Akdeniz; Bektas, Murat
2015-01-01
This study was planned in an attempt to develop a scale for the quality of life in pediatric oncology patients aged 7-12, with child and parents forms. In collecting the study data, we used the Child and Parent Information Form, Visual Quality of Life Scale, Scale for Quality of Life Pediatric Oncology Patients Aged 7-12 and the Scale for the Quality of Life in Pediatric Oncology Patients Aged 7-12 for Parents. We also used Pearson correlation analysis, the Cronbach alpha coefficient, factor analysis and ROC analysis for the study data. In this study, the total Cronbach alpha value of the parent form was 0.96, the total factor load being 0.54-0.90 and the total variance explained was 82.5%. The cutoff point of the parent form was 93 points. The total Cronbach alpha value for the child form was 0.96, with a total factor load of 0.55-0.91 and the total variance being explained was 78.3%. The cutoff point of the child form was 65 points. This study suggests that the Scale for Quality of Life in Pediatric Oncology Patients Aged 7-12 Child and Parents Forms are valid and reliable instruments in assessing the quality of life of children.
Lee, Chin-Pang; Chiu, Yu-Wen; Chu, Chun-Lin; Chen, Yu; Jiang, Kun-Hao; Chen, Jiun-Liang; Chen, Ching-Yen
2016-12-01
The aging males' symptoms (AMS) scale is an instrument used to determine the health-related quality of life in adult and elderly men. The purpose of this study was to synthesize internal consistency (Cronbach's alpha) and test-retest reliability for the AMS scale and its three subscales. Of the 123 studies reviewed, 12 provided alpha coefficients which were then used in the meta-analyses of internal consistency. Seven of the 12 included studies provided test-retest coefficients, and these were used in the meta-analyses of test-retest reliability. The AMS scale had excellent internal consistency [α = 0.89 (95% CI 0.88-0.90)]; the mean alpha estimates across the AMS subscales ranged from 0.79 to 0.82. The AMS scale also had good test-retest reliability [r = 0.85 (95% CI 0.82-0.88]; the test-retest reliability coefficients of the AMS subscales ranged from 0.76 to 0.83. There was significant heterogeneity among the included studies. The AMS scale and the three subscales had fairly good internal consistency and test-retest reliability. Future psychometric studies of the AMS scale should report important characteristics of the participants, details of item scores, and test-retest reliability.
Poon, Vickie Wan-kei; Lam, Linda Chiu-wa; Wong, Samuel Yeung-shan
2008-09-01
With the rapid growth of the older population, early detection of cognitive deficits is crucial in slowing down functional deterioration of the elderly persons. To examine the validity and reliability of the Chinese (Cantonese) version of the Hierarchic Dementia Scale (CV-HDS) for Chinese older persons in Hong Kong. The HDS was translated into Cantonese Chinese. The content and cultural validity were evaluated by six expert panel members. Sixty-two participants with diagnosis of dementia were recruited for evaluation. Inter-rater reliability, test-retest reliability, internal consistency and concurrent validity were examined. The CV-HDS demonstrated satisfactory psychometric properties. inter-rater reliability and test-retest reliability were high (alpha=0.89 and alpha=0.94 respectively). High value of Cronbach's alpha (alpha=0.94) demonstrated good internal consistency. The concurrent validity of CV-HDS, through correlation with its scores with that of the Chinese version of Mini Mental Status Examination, was established (ranged from r=0.58 to r=0.78, p<0.01). The CV-HDS is a reliable and valid instrument for assessing severity of cognitive impairment in Cantonese speaking Chinese people with dementia. It facilitates treatment planning to optimize the effects of functional training and rehabilitation.
Thumboo, Julian; Wu, Yi; Tai, E-Shyong; Gandek, Barbara; Lee, Jeannette; Ma, Stefan; Heng, Derrick; Wee, Hwee-Lin
2013-11-01
We aimed to evaluate the measurement properties of the Singapore English and Chinese versions of the Short-Form 36 version 2 (SF-36v2) Questionnaire, an improved version of the widely used SF-36, for assessing health-related quality of life (HRQoL) in a multi-ethnic urban Asian population in Singapore. SF-36v2 scores and data on medical history, demographic and lifestyle factors from the Singapore Prospective Study Programme were analyzed. Convergent and divergent validity, internal consistency, floor and ceiling effects, known group validity and factor structure of the SF-36v2 were assessed for the English and Chinese versions, respectively. Complete data for 4,917 participants (45.8 %) out of 10,747 eligible individuals were analyzed (survey language: 4,115 English and 802 Chinese). Item-scale correlations exceeded 0.4 for all items of the English SF-36v2 and for all except one item of the Chinese SF-36v2 (bathe and dress: item-scale correlation: 0.36). In the English SF-36v2, Cronbach's alpha exceeded 0.70 for all scales. In the Chinese SF-36v2, Cronbach's alpha exceeded 0.7 on all scales except social functioning (Cronbach's alpha: 0.68). For known groups validity, respondents with chronic medical conditions expectedly reported lower SF-36v2 score on most English and Chinese SF-36v2 scales. In confirmatory factor analysis, the Singapore three-component model was favored over the United States two-component and Japan three-component models. The English and Chinese SF-36v2 are valid and reliable for assessing HRQoL among English and Chinese-speaking Singaporeans. Test-retest reliability and responsiveness of the English and Chinese SF-36v2 in Singapore remain to be evaluated.
[Test for assessing levels of alcohol consumption in Bucaramanga, Colombia: design and validation].
Herrán, Oscar F; Ardila, María F; Barba, Diana M
2008-03-01
Excessive alcohol intake can pose a serious problem in public health. The development of instruments to classify the consumers correctly is the first stage in the epidemiologic investigation. The internal validity and the reliability was evaluated for a test of problematic alcohol consumption (CP-alcohol) in Bucaramanga, Colombia. 2005--2006. This work provides a measure that is internally consistent and improved reliability of diagnostic technology. Six hundred one subjects between 18 and 60 years participated in the test for CP-alcohol on two occasions. At the same time, a survey on biological variables (VB), socioeconomic (VSE) and dietary (D) was administered. The internal consistency of CP-alcohol was evaluated by calculating the coefficient alpha of Cronbach, and the reliability with coefficients of Spearman and Cohens Kappa. To evaluate the associations among problematic consumption, VB, VSE, D and the risk of alcoholism, the prevalence ratios were calculated using binomial regression. The frequency of problematic alcohol consumption was of 46.9 (CI 42.9-50.9). Men presented an increased frequency of problematic alcohol use 1.6 times that of women (p<0.001). The coefficient alpha of Cronbach was moderate for all the questions of the test (minimum 0.41, maximum 0.61). In the first application of CP-alcohol, Cronbachs alpha was 0.63, and, in the second, 0.49. Spearmans correlation coefficient was of 0.87 (CI 0.84-0.90) for the population-for men 0.86 (CI 0.82-0.90) and for women 0.86 (CI 0.82-0.90). The Kappas obtained were very good, 0.70 to 0.89. Sex, pleasure provided by alcoholic drinks , risk of alcoholism according to Cut Down on Drinking, Annoyed by Criticism, Guilty Feeling, and Eye Opener (CAGE) and the quantity of consumed alcohol were all correlated with problematic consumption. CP-alcohol is a useful test for investigating the epidemiology of health problems associated with alcohol use.
Coefficient alpha and interculture test selection.
Thurber, Steven; Kishi, Yasuhiro
2014-04-01
The internal consistency reliability of a measure can be a focal point in an evaluation of the potential adequacy of an instrument for adaptation to another cultural setting. Cronbach's alpha (α) coefficient is often used as the statistical index for such a determination. However, alpha presumes a tau-equivalent test and may constitute an inaccurate population estimate for multidimensional tests. These notions are expanded and examined with a Japanese version of a questionnaire on nursing attitudes toward suicidal patients, originally constructed in Sweden using the English language. The English measure was reported to have acceptable internal consistency (α) albeit the dimensionality of the questionnaire was not addressed. The Japanese scale was found to lack tau-equivalence. An alternative to alpha, "composite reliability," was computed and found to be below acceptable standards in magnitude and precision. Implications for research application of the Japanese instrument are discussed. © The Author(s) 2012.
Development of an opioid-related Overdose Risk Behavior Scale (ORBS).
Pouget, Enrique R; Bennett, Alex S; Elliott, Luther; Wolfson-Stofko, Brett; Almeñana, Ramona; Britton, Peter C; Rosenblum, Andrew
2017-01-01
Drug overdose has emerged as the leading cause of injury-related death in the United States, driven by prescription opioid (PO) misuse, polysubstance use, and use of heroin. To better understand opioid-related overdose risks that may change over time and across populations, there is a need for a more comprehensive assessment of related risk behaviors. Drawing on existing research, formative interviews, and discussions with community and scientific advisors an opioid-related Overdose Risk Behavior Scale (ORBS) was developed. Military veterans reporting any use of heroin or POs in the past month were enrolled using venue-based and chain referral recruitment. The final scale consisted of 25 items grouped into 5 subscales eliciting the number of days in the past 30 during which the participant engaged in each behavior. Internal reliability, test-retest reliability and criterion validity were assessed using Cronbach's alpha, intraclass correlations (ICC) and Pearson's correlations with indicators of having overdosed during the past 30 days, respectivelyInternal reliability, test-retest reliability and criterion validity were assessed using Cronbach's alpha, intraclass correlations (ICC) and Pearson's correlations with indicators of having overdosed during the past 30 days, respectively. Data for 220 veterans were analyzed. The 5 subscales-(A) Adherence to Opioid Dosage and Therapeutic Purposes; (B) Alternative Methods of Opioid Administration; (C) Solitary Opioid Use; (D) Use of Nonprescribed Overdose-associated Drugs; and (E) Concurrent Use of POs, Other Psychoactive Drugs and Alcohol-generally showed good internal reliability (alpha range = 0.61 to 0.88), test-retest reliability (ICC range = 0.81 to 0.90), and criterion validity (r range = 0.22 to 0.66). The subscales were internally consistent with each other (alpha = 0.84). The scale mean had an ICC value of 0.99, and correlations with validators ranged from 0.44 to 0.56. These results constitute preliminary evidence for the reliability and validity of the new scale. If further validated, it could help improve overdose prevention and response research and could help improve the precision of overdose education and prevention efforts.
Roaldsen, Kirsti Skavberg; Måøy, Åsa Blad; Jørgensen, Vivien; Stanghelle, Johan Kvalvik
2016-05-01
Translation of the Spinal Cord Injury Falls Concern Scale (SCI-FCS), and investigation of test-retest reliability on item-level and total-score-level. Translation, adaptation and test-retest study. A specialized rehabilitation setting in Norway. Fifty-four wheelchair users with a spinal cord injury. The median age of the cohort was 49 years, and the median number of years after injury was 13. Interventions/measurements: The SCI-FCS was translated and back-translated according to guidelines. Individuals answered the SCI-FCS twice over the course of one week. We investigated item-level test-retest reliability using Svensson's rank-based statistical method for disagreement analysis of paired ordinal data. For relative reliability, we analyzed the total-score-level test-retest reliability with intraclass correlation coefficients (ICC2.1), the standard error of measurement (SEM), and the smallest detectable change (SDC) for absolute reliability/measurement-error assessment and Cronbach's alpha for internal consistency. All items showed satisfactory percentage agreement (≥69%) between test and retest. There were small but non-negligible systematic disagreements among three items; we recovered an 11-13% higher chance for a lower second score. There was no disagreement due to random variance. The test-retest agreement (ICC2.1) was excellent (0.83). The SEM was 2.6 (12%), and the SDC was 7.1 (32%). The Cronbach's alpha was high (0.88). The Norwegian SCI-FCS is highly reliable for wheelchair users with chronic spinal cord injuries.
Hasanpour, Neda; Attarbashi Moghadam, Behrouz; Sami, Ramin; Tavakol, Kamran
2016-08-01
The clinical COPD questionnaire (CCQ) has been developed to measure the health status of COPD patients. The aim of this study was to translate CCQ into the Persian language and assess the validity and reliability of the translated version. We used a forward-backward procedure to translate the questionnaire. In a cross-sectional study 100 COPD patients and 50 healthy subjects over 40 years old were selected to assess the reliability and construct validity of the instrument. The face and content validity were used for the questionnaire validity. Validity was examined in a population of patients with COPD, using the Persian validated version of the St George's Respiratory Questionnaire (PSGRQ). In order to assess the questionnaire's reliability, the Intraclass correlation coefficient (ICC) and Cronbach's alpha were calculated. Test-retest reliability was tested by re-administering the Persian version of the CCQ (PCCQ) after 1 week. Test-retest carry out of data demonstrates that the PCCQ has excellent reliability (ICC for all 3 domains were higher than 0.9). Internal consistency was found by Cronbach's alpha to be 0.96, 0.94, 0.97, and 0.98 for the symptom, mental state, functional state and total scores respectively. In addition, the correlation between the components of PCCQ and PSGRQ showed satisfactory construct validity. Analyzing the data from healthy subjects and patients divulged that the PCCQ has acceptable discriminant validity. In general, the PCCQ had satisfactory reliability and validity for assessing health-related quality of life status of Iranian COPD patients.
Cultural Adaptation Quality of Family Life Scale for the Brazilian Portuguese.
Jorge, Bianca Miguel; Levy, Cilmara Cristina Alves da Costa; Granato, Lídio
2015-01-01
To culturally adapt the Family Quality of Life Scale to the Brazilian Portuguese version and evaluate the instrument reliability and family quality of life of those who have children with hearing loss. The process of cultural adaptation of the scale followed the steps of the Guidelines for the Process of Cross-Cultural Adaptation of Self-Report Measure. It was conducted in three stages: translation, back translation, and application in a pilot sample, as a way to check the comprehension difficulties of the items. After it had been completed, it was administered to 41 families who have children with hearing loss and, with their results, the quality of life and reliability were analyzed based on the Cronbach's alpha statistical test. In the first version (translation), among the 25 items, there were differences between the translators only in four items; after the corrections, the second version was done (back translation), in which other four more differences were found. Finally, after the final corrections, the last version was developed and used in the pilot sample without differences. Thus, it was applied to families with deaf children, who believe to be satisfied as to their quality of life. The Cronbach's alpha test found that the scale shows a satisfactory reliability. The Brazilian Portuguese version of the Family Quality of Life Scale is a tool of easy use and satisfactory reliability. The families are satisfied with their family quality of life.
Nehzat, F; Huda, B Z; Tajuddin, S H Syed
2014-03-01
Job Content Questionnaire (JCQ) has been proven a reliable and valid instrument to assess job stress in many countries and among various occupations. In Malaysia, both English and Malay versions of the JCQ have been administered to automotive workers, schoolteachers, and office workers. This study assessed the reliability and validity of the instrument with research laboratory staff in a university. A cross sectional study was conducted among 258 research laboratory staff in Universiti Putra Malaysia (UPM). Malaysian laboratory staff who have worked for at least one year were randomly selected from nine faculties and institutes in the university that have research laboratory. A self-administered English and Malay version of Job Content Questionnaire (JCQ) was used. Three major scales of JCQ: decision latitude, psychological job demands, and social support were assessed. Cronbach's alpha coefficients of two scales were acceptable, decision latitude and psychological job demands (0.70 and 0.72, respectively), while Cronbach's alpha coefficient for social support (0.86) was good. Exploratory factor analysis showed five factors that correspond closely to the theoretical construct of the questionnaire. The results of this research suggest that the JCQ is reliable and valid for examining psychosocial work situations and job strain among research laboratory staff. Further studies should be done for confirmative results, and further evaluation is needed on the decision authority subscale for this occupation.
Slagers, Anton J; Reininga, Inge H F; van den Akker-Scheek, Inge
2017-02-01
The ACL-Return to Sport after Injury scale (ACL-RSI) measures athletes' emotions, confidence in performance, and risk appraisal in relation to return to sport after ACL reconstruction. Aim of this study was to study the validity and reliability of the Dutch version of the ACL-RSI (ACL-RSI (NL)). Total 150 patients, who were 3-16 months postoperative, completed the ACL-RSI(NL) and 5 other questionnaires regarding psychological readiness to return to sports, knee-specific physical functioning, kinesiophobia, and health-specific locus of control. Construct validity of the ACL-RSI(NL) was determined with factor analysis and by exploring 10 hypotheses regarding correlations between ACL-RSI(NL) and the other questionnaires. For test-retest reliability, 107 patients (5-16 months postoperative) completed the ACL-RSI(NL) again 2 weeks after the first administration. Cronbach's alpha, Intraclass Correlation Coefficient (ICC), SEM, and SDC, were calculated. Bland-Altman analysis was conducted to assess bias between test and retest. Nine hypotheses (90%) were confirmed, indicating good construct validity. The ACL-RSI(NL) showed good internal consistency (Cronbach's alpha 0.94) and test-retest reliability (ICC 0.93). SEM was 5.5 and SDC was 15. A significant bias of 3.2 points between test and retest was found. Therefore, the ACL-RSI(NL) can be used to investigate psychological factors relevant to returning to sport after ACL reconstruction.
Saad, Karen Ruggeri; Colombo, Alexandra S; João, Silvia M Amado
2009-01-01
The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. The Cronbach alpha values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). The photogrammetric measures were found to be reproducible in this study and could be used as supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis.
Hashemian, Masoumeh; Aminshokravi, Farkhonde; Hidarnia, Alireza; Lamyian, Minoor; Hassanpour, Kazem; Akaberi, Arash; Moshki, Mahdi
2014-09-01
To determine the Persian version's reliability and validity of the Multidimensional Health Locus of Control and God Health Locus of Control scales among women with family history of breast cancer. The cross-sectional study was conducted in Sabzevar, Iran, in 2012. It randomly selected women with family members affected by breast cancer. Predesigned questionnaires were completed through interviews. Content and face validity was evaluated using the opinions of a panel of experts, and construct validity was confirmed by applying confirmatory factor analysis.The instruments' reliability was assessed using Cronbach's alpha and test-retest reliability. There were 200 women in the study with their age ranging between 18 and 69 years and revealed the following; root mean square error of approximation for Multidimensional Health Locus of Control Scale = 0.013, and God Locus of Health Control Scale = 0.077; comparative fit index = 0.999, 0.998; incremental fit index = 0.999, 0.998;Tucker-Lewis fit index = 0.998, 0.998; and normed fit index = 0.983, 0.997 respectively. Cronbach's alpha was 0.61 for Internal Health Locus of Control, 0.8 for Chance Health Locus of Control, 0.68 for Power Health Locus of Control and 0.9 for God Locus Health Control. The Persian version of the subscales supported the main version.
Rodrigues, Marcelo F; Michel-Crosato, Edgard; Cardoso, Jefferson R; Traebert, Jefferson
2009-06-01
Cross-cultural translation and psychometric testing. To translate and cross-culturally adapt the Quebec Back Pain Disability Scale (QDS) to Brazilian Portuguese and to examine its validity and reliability. Current literature shows the need to adopt reliable and internationally standardized methods for the analysis of low back pain. To our knowledge, this specific questionnaire has not been translated and validated for Portuguese-speaking patients. The translation and cross-cultural adaptation of the QDS were developed in agreement with internationally recommended methodology, and the resulting product was evaluated in this study with 54 consecutive patients. Internal consistency was obtained through Cronbach's alpha; reliability was estimated through the intraclass correlation coefficient and the Bland and Altman agreement (d = mean difference). Validity was determined by correlating the scores of the Brazil-QDS with the Brazilian version of the Roland-Morris Questionnaire and Visual Analogue Pain Scale by means of the Spearman rank correlation coefficient. The internal consistency obtained was excellent (Cronbach's alpha = 0.97). Intraobserver and interobserver reliability were considered strong (ICC = 0.93-d = 0.68 and 0.96-d = 0.57, respectively). The correlation with Brazilian Roland-Morris Questionnaire and with the Visual Analogue Scale was high (r = 0.857; r = 0.758, respectively). The data showed that the process of translation and cross-cultural adaptation were successful and that the adapted instrument demonstrated excellent psychometric properties.
[Multiple mini interviews before the occupation of main training posts in paediatrics].
Hertel, Niels Thomas; Bjerager, Mia; Boas, Malene; Boisen, Kirsten A; Børch, Klaus; Frederiksen, Marianne Sjølin; Holm, Kirsten; Grum-Nymann, Anette; Johnsen, Martin M; Whitehouse, Stine; Balslev, Thomas
2013-09-09
Interviews are mandatory in Denmark when selecting doctors for training positions. We used multiple mini interviews (MMI) at four recruitment rounds for the main training posts in paediatrics. In total, 125 candidates were evaluated and assessed by CV and MMI (4-5 stations). Reliability for individual stations in MMI assessed by Cronbach's alpha was adequate (0.63-0.92). The overall reliability assessed by G-theory was lower, suggesting that different skills were tested. The acceptability was high. Our experiences with MMI suggest good feasibility and reliability. An increasing number of stations may improve the overall reliability.
Blackhall, Leslie J; Erickson, Jeanne; Brashers, Valentina; Owen, John; Thomas, Shannon
2014-01-01
Helping families make end-of-life decisions requires close collaboration between physicians and nurses. However, medical and nursing students have little formal training in how to collaborate in this task, and few instruments are available to measure collaborative behaviors. The objective of this project was to develop and validate observational assessment tools to measure specific interprofessional competencies in medical and nursing students related to end-of-life discussions. A literature search for evidence-based guidelines and competencies and focus groups with an expert panel of nurses and physicians were used to outline best collaborative practice behaviors for nurses and physicians in an end-of-life decision making simulation. The panel used these practice-behavior checklists to rate videotaped student scenarios and then refined the checklists for validity and clarity until the tools had acceptable inter-rater reliability. The setting was a workshop teaching end-of-life communication to third-year nursing and medical students. Inter-rater reliability was measured using percent agreement and kappa; internal consistency was measured using Cronbach's alpha. Collaborative behaviors objective assessment tools (CBOATs) for nursing and medical students were developed. For the medical CBOAT we found 85% agreement between raters, with an overall kappa of 0.744 and Cronbach's alpha of 0.806. For the nursing CBOAT there was 81% agreement, with a kappa of 0.686 and Cronbach's alpha of 0.845. Development of an end-of-life CBOAT clarified the important collaborative behaviors needed by physician and nurse. The resulting instruments provide a helpful guide for teaching interprofessional sessions related to the end of life and measuring student outcomes using an objective strategy.
Biringer, Eva; Tjoflåt, Marit
2018-01-25
The Recovery Assessment Scale-revised (RAS-R) is a self-report instrument measuring mental health recovery. The purpose of the present study was to translate and adapt the RAS-R into the Norwegian language and to investigate its psychometric properties in terms of factor structure, convergent and discriminant validity and reliability in the Norwegian context. The present study is a cross-sectional multi-centre study. After a pilot test, the Norwegian version of the RAS-R was distributed to 231 service users in mental health specialist and community services. The factor structure of the instrument was investigated by a confirmatory factor analysis (CFA), and internal consistency was assessed by Cronbach's alpha. The RAS-R was found to be acceptable and feasible for service users. The original five-factor structure was confirmed. All model fit indices, including the standardised root mean square residual (SRMR), which is independent of the χ 2 -test, met the criteria for an acceptable model fit. Internal consistencies within sub-scales as measured by Cronbach's alpha ranged from 0.65 to 0.85. Cronbach's alpha for the total scale was 0.90. As expected, some redundancy between factors existed (in particular among the factors Personal confidence and hope, Goal and success orientation and Not dominated by symptoms). The Norwegian RAS-R showed acceptable psychometric properties in terms of convergent validity and reliability, and fit indices from the CFA confirmed the original factor structure. We recommend the Norwegian RAS-R as a tool in service users' and health professionals' collaborative work towards the service users' recovery goals and as an outcome measure in larger evaluations.
The psychometric properties of exercise benefits/barriers scale among women.
Farahani, Leila Amiri; Parvizy, Soroor; Mohammadi, Eesa; Asadi-Lari, Mohsen; Kazemnejad, Anoshiravan; Hasanpoor-Azgahdy, Seyede Batool; Taghizadeh, Ziba
2017-07-01
Despite the numerous health benefits of regular physical activity (PA), physical inactivity is a major health issue among women. The goal of the current study was to measure the validity and reliability assessment of the exercise benefits/barriers scale among women between the ages of 18 and 65 years. This study was carried out among women residing in Khoramroudi neighborhood in Tehran between December 2013 and February 2014. In this descriptive, methodological study, 278 women residing in Khoramroudi neighborhood in Tehran between December 2013 and February 2014 completed three questionnaires: the demographic data form, the Exercise Benefits/Barriers Scale. The construct validity, internal consistency, and stability of the study were measured by confirmatory factor analyses, Cronbach's alpha, and Spearman Brown correlation coefficient by using SPSS 21 and LISREL 8.80, respectively. The confirmatory factor analysis showed the Persian version of EBBS was structured well. The Cronbach's alpha coefficients for the total scale and its subscales were 0.927, 0.94 and 0.82, respectively. Spearman Brown correlation coefficient also showed good test-retest reliability. The results of this study verified the reliability and validity of the applied instrument and introduced it as a tool to measure the benefits and barriers of physical activity among Iranian women.
Health related quality of life in disorders of defecation: the Defecation Disorder List
Voskuijl, W; van der Zaag-Loon..., H J; Ketel, I; Grootenhuis, M; Derkx, B; Benninga, M
2004-01-01
Background: Constipation and encopresis frequently cause problems with respect to emotional wellbeing, and social and family life. Instruments to measure Health Related Quality of Life (HRQoL) in these disorders are not available. Methods: A disease specific HRQoL instrument, the "Defecation Disorder List" (DDL) for children with constipation or functional non-retentive faecal soiling (FNRFS) was developed using accepted guidelines. For each phase of the process, different samples of patients were used. The final phase of development included 27 children. Reliability was assessed in two ways: internal consistency of domains with Cronbach's alpha, and test-retest reliability with intra-class correlation coefficients (ICC). To assess validity, comparable items and domains were correlated with Tacqol, a generic HRQoL instrument for children (TNO-AZL). Results: In the final phase of the development, 27 children completed the instrument. It consisted of 37 items in four domains. The response rate was 96%. Reliability was good for all domains, with Cronbach's alpha values ranging from 0.61 to 0.76. Measures of test-retest stability were good for all four domains with ICCs ranging from 0.82 to 0.92. Validity based on comparison with the Tacqol instrument was moderate. Conclusion: The DDL is promising as a measure of HRQoL in childhood defecation disorders. PMID:15557046
Construction of a survey to assess workload and fatigue among AMT operators in Mexico.
Hernández Arellano, Juan Luis; Ibarra Mejía, Gabriel; Serratos Pérez, J Nieves; García Alcaraz, Jorge Luis; Brunette, María Julia
2012-01-01
Operators of machinery classified as Advanced Manufacturing Technology (AMT) are exposed to high levels of workload and fatigue. However, only few studies have been conducted on this topic in Hispanic-American countries workers. Several instruments be used to assess workload and fatigue; however, only few of them have been adapted to Spanish language. This paper reports on the development and validity testing of a survey instrument in Spanish, aiming to subjectively assess workload and fatigue among AMT operators in Mexico. After an exhaustive literature review in search of already available measurement instruments, they were adapted for content and later translated into Spanish; a pilot test was conducted to evaluate validity and reliability; afterwards appropriate modifications were made to the testing instruments. Final version of the instrument was applied to a group of 121 operators of CNC lathes. Reliability was analyzed using KMO and Cronbach alpha indices. For the assessment of workload, both NASA-TLX and ISTAS 21 methods were incorporated to the survey instrument. As for fatigue assessment tools, these were SOFI-S, FAS and OFER questionnaires. RESULTS show KMO value and Cronbach alpha above 0.6.Conclusions. The survey instrument as designed, allows the collection of reliable and valid data regarding workload and fatigue among AMT operators in Mexico.
Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Razi, Shiva; Mardani-Kivi, Mohsen; Reza Kachooei, Amir
2015-09-01
Oxford shoulder score is a specific 12-item patient-reported tool for evaluation of patients with inflammatory and degenerative disorders of the shoulder. Since its introduction, it has been translated and culturally adapted in some Western and Eastern countries. The aim of this study was to translate the Oxford Shoulder Score (OSS) in Persian and to test its validity and reliability in Persian speaking population in Iran. One hundred patients with degenerative or inflammatory shoulder problem participated in the survey in 2012. All patients completed the Persian version of OSS, Persian DASH and the SF-36 for testing validity. Randomly, 37 patients filled out the Persian OSS again three days after the initial visit to assess the reliability of the questionnaire. Cronbach's alpha coefficient was 0.93. The intraclass correlation coefficient was 0.93. In terms of validity, there was a significant correlation between the Persian OSS and DASH and SF-36 scores (P < 0.001). The Persian version of the OSS proved to be a valid, reliable, and reproducible tool as demonstrated by high Cronbach's alpha and Pearson's correlation coefficients. The Persian transcript of OSS is administrable to Persian speaking patients with shoulder condition and it is understandable by them.
2010-01-01
Background Today, many organizations have adopted some kind of empowerment initiative for at least part of their workforce. Over the last two decades, two complementary perspectives on empowerment at work have emerged: structural and psychological empowerment. Psychological empowerment is a motivational construct manifested in four cognitions: meaning, competence, self-determination and impact. The aim of this article is to examine the construct validity and reliability of the Turkish translation of Spreitzer's psychological empowerment scale in a culturally diverse environment. Methods The scale contains four dimensions over 12 statements. Data were gathered from 260 nurses and 161 physicians. The dimensionality of the scale was evaluated by exploratory factor analyses. To investigate the multidimensional nature of the empowerment construct and the validity of the scale, first- and second-order confirmatory factor analysis was conducted. Furthermore, Cronbach alpha coefficients were assessed to investigate reliability. Results Exploratory factor analyses revealed that four factors in both solutions. The first- and second-order factor analysis indicated an acceptable fit between the data and the theoretical model for nurses and physicians. Cronbach alpha coefficients varied between 0.81-0.94 for both groups, which may be considered satisfactory. Conclusions The analyses indicated that the psychometric properties of the Turkish version of the scale can be considered satisfactory. PMID:20214770
McEvoy, Maureen Patricia; Williams, Marie T; Olds, Timothy Stephen
2010-01-01
Previous survey tools operationalising knowledge, attitudes or beliefs about evidence-based practice (EBP) have shortcomings in content, psychometric properties and target audience. This study developed and psychometrically assessed a self-report trans-professional questionnaire to describe an EBP profile. Sixty-six items were collated from existing EBP questionnaires and administered to 526 academics and students from health and non-health backgrounds. Principal component factor analysis revealed the presence of five factors (Relevance, Terminology, Confidence, Practice and Sympathy). Following expert panel review and pilot testing, the 58-item final questionnaire was disseminated to 105 subjects on two occasions. Test-retest and internal reliability were quantified using intra-class correlation coefficients (ICCs) and Cronbach's alpha, convergent validity against a commonly used EBP questionnaire by Pearson's correlation coefficient and discriminative validity via analysis of variance (ANOVA) based on exposure to EBP training. The final questionnaire demonstrated acceptable internal consistency (Cronbach's alpha 0.96), test-retest reliability (ICCs range 0.77-0.94) and convergent validity (Practice 0.66, Confidence 0.80 and Sympathy 0.54). Three factors (Relevance, Terminology and Confidence) distinguished EBP exposure groups (ANOVA p < 0.001-0.004). The evidence-based practice profile (EBP(2)) questionnaire is a reliable instrument with the ability to discriminate for three factors, between respondents with differing EBP exposures.
Development and Validation of the Numeracy Understanding in Medicine Instrument Short Form
Schapira, Marilyn M.; Walker, Cindy M.; Miller, Tamara; Fletcher, Kathlyn A; Ganschow, Pamela G.; Jacobs, Elizabeth A; Imbert, Diana; O'Connell, Maria; Neuner, Joan M.
2014-01-01
Background Health numeracy can be defined as the ability to understand and use numeric information and quantitative concepts in the context of health. We previously reported the development of the Numeracy Understanding in Medicine Instrument (NUMi); a 20-item test developed using item response theory. We now report the development and validation of a short form of the NUMi. Methods Item statistics were used to identify a subset of 8-items representing a range of difficulty and content areas. Internal reliability was evaluated with Cronbach's alpha. Divergent and convergent validity was assessed by comparing scores of the S-NUMI with existing measures of education, print and numeric health literacy, mathematic achievement, cognitive reasoning, and the original NUMi. Results The 8-item scale had adequate reliability (Cronbach's alpha: 0.72) and was strongly correlated to the 20-item NUMi (0.92). The S-NUMi scores were strongly correlated with the Lipkus numeracy test (0.62), Wide Range of Achievement Test-Mathematics (WRAT-M) (0.72), and Wonderlic cognitive reasoning test (0.76). Moderate correlation was found with education level (0.58) and print literacy as measured by the TOFHLA (0.49). Conclusion The short Numeracy Understanding in Medicine Instrument is a reliable and valid measure of health numeracy feasible for use in clinical and research settings. PMID:25315596
Validation of self assessment patient knowledge questionnaire for heart failure patients.
Lainscak, Mitja; Keber, Irena
2005-12-01
Several studies showed insufficient knowledge and poor compliance to non-pharmacological management in heart failure patients. Only a limited number of validated tools are available to assess their knowledge. The aim of the study was to test our 10-item Patient knowledge questionnaire. The Patient knowledge questionnaire was administered to 42 heart failure patients from Heart failure clinic and to 40 heart failure patients receiving usual care. Construct validity (Pearson correlation coefficient), internal consistency (Cronbach alpha), reproducibility (Wilcoxon signed rank test), and reliability (chi-square test and Student's t-test for independent samples) were assessed. Overall score of the Patient knowledge questionnaire had the strongest correlation to the question about regular weighing (r=0.69) and the weakest to the question about presence of heart disease (r=0.33). There was a strong correlation between question about fluid retention and questions assessing regular weighing, (r=0.86), weight of one litre of water (r=0.86), and salt restriction (r=0.57). The Cronbach alpha was 0.74 and could be improved by exclusion of questions about clear explanation (Chronbach alpha 0.75), importance of fruit, soup, and vegetables (Chronbach alpha 0.75), and self adjustment of diuretic (Chronbach alpha 0.81). During reproducibility testing 91% to 98% of questions were answered equally. Patients from Heart failure clinic scored significantly better than patients receiving usual care (7.9 (1.3) vs. 5.7 (2.2), p<0.001). Patient knowledge questionnaire is a valid and reliable tool to measure knowledge of heart failure patients.
Validation of Medical Tourism Service Quality Questionnaire (MTSQQ) for Iranian Hospitals.
Qolipour, Mohammad; Torabipour, Amin; Khiavi, Farzad Faraji; Malehi, Amal Saki
2017-03-01
Assessing service quality is one of the basic requirements to develop the medical tourism industry. There is no valid and reliable tool to measure service quality of medical tourism. This study aimed to determine the reliability and validity of a Persian version of medical tourism service quality questionnaire for Iranian hospitals. To validate the medical tourism service quality questionnaire (MTSQQ), a cross-sectional study was conducted on 250 Iraqi patients referred to hospitals in Ahvaz (Iran) from 2015. To design a questionnaire and determine its content validity, the Delphi Technique (3 rounds) with the participation of 20 medical tourism experts was used. Construct validity of the questionnaire was assessed through exploratory and confirmatory factor analysis. Reliability was assessed using Cronbach's alpha coefficient. Data were analyzed by Excel 2007, SPSS version18, and Lisrel l8.0 software. The content validity of the questionnaire with CVI=0.775 was confirmed. According to exploratory factor analysis, the MTSQQ included 31 items and 8 dimensions (tangibility, reliability, responsiveness, assurance, empathy, exchange and travel facilities, technical and infrastructure facilities and safety and security). Construct validity of the questionnaire was confirmed, based on the goodness of fit quantities of model (RMSEA=0.032, CFI= 0.98, GFI=0.88). Cronbach's alpha coefficient was 0.837 and 0.919 for expectation and perception questionnaire. The results of the study showed that the medical tourism SERVQUAL questionnaire with 31 items and 8 dimensions was a valid and reliable tool to measure service quality of medical tourism in Iranian hospitals.
[Validation and reliability of Turkish Singing Voice Handicap index].
Denizoğlu, İsmail İlter; Şahin, Mustafa; Kazancıoğlu, Alper; Dağdelen, Zibelhan; Akdeniz, Serap; Oğuz, Haldun; Kılıç, Mehmet Akif; Yücedağ, Aslı; Öğüt, Mehmet Fatih
2016-01-01
This study aims to constitute a valid and reliable Turkish version of the original Singing Voice Handicap Index. An authorized committee assessed the reliability and validity of the content, scope, and language of the original Singing Voice Handicap Index which underwent a back translation process. The Turkish version of the questionnaire was answered twice with a 7 to 10-day interval by two singing voice groups with or without singing voice problems. The reliability and validity analyses were performed based on these answers. Of a total of 123 individuals (64 females, 59 males; mean age 26.2±7.3 years), 81 were without a voice pathology and 42 were with a voice pathology. The total Cronbach's alpha coefficient was 0.917. The item-total correlations ranged between 0.51 and 0.89. The weighted kappa values of test-retest correlation values of the items were 0.82-0.91. The Cronbach's alpha values of two part of the questionnaire based on the split-half method were 0.89 and 0.84. The mean total scale scores were 21.8±18.5 and 53.6±28.9 in normal and pathology groups, respectively and there was a statistically significant difference in scores between these two groups (p=0.000). The Turkish version of the Singing Voice Handicap Index is a valid and reliable scale which can be used in the evaluation of voice problems of Turkish-speaking singing voice users.
Ang, B H; Chen, W S; Ngin, C K; Oxley, J A; Lee, S W H
2018-02-01
This study aimed to examine the reliability and validity of the English and Malay versions of the Driving and Riding Questionnaire. An observational study with a mix-method approach by utilising both questionnaire and short debriefing interviews. Forward and backward translations of the original questionnaire were performed. The translated questionnaire was assessed for clarity by a multidisciplinary research team, translators, and several Malay native speakers. A total of 24 subjects participated in the pilot study. Reliability (Cronbach's alpha) and validity (content validity) of the original and translated questionnaires were examined. The English and Malay versions of the Driving and Riding Questionnaire were found to be reliable tools in measuring driving behaviours amongst older drivers and riders, with Cronbach's alpha of 0.9158 and 0.8919, respectively. For content validity, the questionnaires were critically reviewed in terms of relevance, clarity, simplicity, and ambiguity. The feedback obtained from participants addressed various aspects of the questionnaire related to the improvement of wordings used and inclusion of visual guide to enhance the understanding of the items in the questionnaire. This feedback was incorporated into the final versions of the English and Malay questionnaires. The findings of this study demonstrated both the English and Malay versions of the Driving and Riding Questionnaire to be valid and reliable. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Contributing Factors to Pre-Service Mathematics Teachers' e-Readiness for ICT Integration
ERIC Educational Resources Information Center
Apeanti, Wilson Osafo
2016-01-01
This study investigated pre-service teachers' e-readiness to use ICTs for instruction. The primary data source for the study is a set of survey instrument responded by 126 pre-service mathematics teachers at the University of Education Winneba, Ghana. The survey instrument has a reliability scales (Cronbach's Alpha values) of 0.726. Multiple…
Easier Said than Done: Rejoinder on Sijtsma and on Green and Yang
ERIC Educational Resources Information Center
Davenport, Ernest C.; Davison, Mark L.; Liou, Pey-Yan; Love, Quintin U.
2016-01-01
The main points of Sijtsma and Green and Yang in Educational Measurement: Issues and Practice (34, 4) are that reliability, internal consistency, and unidimensionality are distinct and that Cronbach's alpha may be problematic. Neither of these assertions are at odds with Davenport, Davison, Liou, and Love in the same issue. However, many authors…
Chen, Yu-Ming; He, Li-Ping; Mai, Jin-Cheng; Hao, Yuan-Tao; Xiong, Li-Hua; Chen, Wei-Qing; Wu, Jiang-Nan
2008-06-01
To evaluate the reliability and validity of parent proxy-report scales of Pediatric Quality of Life Inventory Version 4.0 (PedsQL 4.0) Generic Core Scales, the Chinese Version. 3493 school students aged 6-18 years were recruited using multistage cluster sampling method. Health-related quality of life was assessed using the above-mentioned PedsQL 4.0 scales. The internal consistency was assessed, using Cronbach's a coefficient, while its validity was tested through correlation analysis, t-test and exploratory factor analysis. The internal consistency reliability for Total Scale Score (Cronbach's alpha = 0.90), Physical Health Summary Score (alpha= 0.81), and Psychosocial Health Summary Score (alpha= 0.89) were excellent. Six major factors were extracted by factor analysis which basically matched the designed structure of the original version accounting for nearly 66% of the variance. The total Scale Score significantly decreased by 3.5 to 13.3 (P < 0.05) in children and adolescents who had diseases including cold, skin hypersensitiveness, food allergy, courbature or arthralgia, breathlessness with a frequency of 6 times or more per year or had asthma as compared to those with lower frequency (< or = 5 times/y) of the diseases or without asthma. We found moderate to high correlations between items and the subscales. Correlation coefficients ranged between 0.45 to 0.84 (P < 0.01). The reliability and validity of the parent proxy-report scales of PedsQL 4.0 Generic Core Scales of the Chinese Version were as good as the original version. Our findings suggested that the scales could be applied to evaluate the health-related quality of life in childhood children in similar Chinese regions to Guangzhou.
Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study
Hashmi, Ali M.; Naz, Shahana; Asif, Aftab; Khawaja, Imran S.
2016-01-01
Objective: To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. Methods: After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. Results: The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. Conclusion: The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research. PMID:28083049
Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study.
Hashmi, Ali M; Naz, Shahana; Asif, Aftab; Khawaja, Imran S
2016-01-01
To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research.
Reliability and validity of television food advertising questionnaire in Malaysia.
Zalma, Abdul Razak; Safiah, Md Yusof; Ajau, Danis; Khairil Anuar, Md Isa
2015-09-01
Interventions to counter the influence of television food advertising amongst children are important. Thus, reliable and valid instrument to assess its effect is needed. The objective of this study was to determine the reliability and validity of such a questionnaire. The questionnaire was administered twice on 32 primary schoolchildren aged 10-11 years in Selangor, Malaysia. The interval between the first and second administration was 2 weeks. Test-retest method was used to examine the reliability of the questionnaire. Intra-rater reliability was determined by kappa coefficient and internal consistency by Cronbach's alpha coefficient. Construct validity was evaluated using factor analysis. The test-retest correlation showed moderate-to-high reliability for all scores (r = 0.40*, p = 0.02 to r = 0.95**, p = 0.00), with one exception, consumption of fast foods (r = 0.24, p = 0.20). Kappa coefficient showed acceptable-to-strong intra-rater reliability (K = 0.40-0.92), except for two items under knowledge on television food advertising (K = 0.26 and K = 0.21) and one item under preference for healthier foods (K = 0.33). Cronbach's alpha coefficient indicated acceptable internal consistency for all scores (0.45-0.60). After deleting two items under Consumption of Commonly Advertised Food, the items showed moderate-to-high loading (0.52, 0.84, 0.42 and 0.42) with the Scree plot showing that there was only one factor. The Kaiser-Meyer-Olkin was 0.60, showing that the sample was adequate for factor analysis. The questionnaire on television food advertising is reliable and valid to assess the effect of media literacy education on television food advertising on schoolchildren. © The Author (2013). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Kim, Hee-Ju; Abraham, Ivo
2017-01-01
Evidence is needed on the clinicometric properties of single-item or short measures as alternatives to comprehensive measures. We examined whether two single-item fatigue measures (i.e., Likert scale, numeric rating scale) or a short fatigue measure were comparable to a comprehensive measure in reliability (i.e., internal consistency and test-retest reliability) and validity (i.e., convergent, concurrent, and predictive validity) in Korean young adults. For this quantitative study, we selected the Functional Assessment of Chronic Illness Therapy-Fatigue for the comprehensive measure and the Profile of Mood States-Brief, Fatigue subscale for the short measure; and constructed two single-item measures. A total of 368 students from four nursing colleges in South Korea participated. We used Cronbach's alpha and item-total correlation for internal consistency reliability and intraclass correlation coefficient for test-retest reliability. We assessed Pearson's correlation with a comprehensive measure for convergent validity, with perceived stress level and sleep quality for concurrent validity and the receiver operating characteristic curve for predictive validity. The short measure was comparable to the comprehensive measure in internal consistency reliability (Cronbach's alpha=0.81 vs. 0.88); test-retest reliability (intraclass correlation coefficient=0.66 vs. 0.61); convergent validity (r with comprehensive measure=0.79); concurrent validity (r with perceived stress=0.55, r with sleep quality=0.39) and predictive validity (area under curve=0.88). Single-item measures were not comparable to the comprehensive measure. A short fatigue measure exhibited similar levels of reliability and validity to the comprehensive measure in Korean young adults. Copyright © 2016 Elsevier Ltd. All rights reserved.
Reliability of the Ego-Grasping Scale.
Lester, David
2012-04-01
Research using Knoblauch and Falconer's Ego-Grasping Scale is reviewed. Using a sample of 695 undergraduate students, the scale had moderate reliability (Cronbach alpha, odd-even numbered items, and test-retest), but a principal-components analysis with a varimax rotation identified five components, indicating heterogeneity in the content of the items. Lower Ego-Grasping scores appear to be associated with better psychological health. The scale has been translated and used with Korean, Kuwaiti, and Turkish students, indicating that the scale can be useful in cross-cultural studies.
The Effects of Methods of Imputation for Missing Values on the Validity and Reliability of Scales
ERIC Educational Resources Information Center
Cokluk, Omay; Kayri, Murat
2011-01-01
The main aim of this study is the comparative examination of the factor structures, corrected item-total correlations, and Cronbach-alpha internal consistency coefficients obtained by different methods used in imputation for missing values in conditions of not having missing values, and having missing values of different rates in terms of testing…
ERIC Educational Resources Information Center
Chansirisira, Pacharawit
2012-01-01
The research aimed to investigate the core competency elements and the factors affecting the performance efficiency of the civil service teachers in the northeastern region, Thailand. The research procedure consisted of two steps. In the first step, the data were collected using a questionnaire with the reliability (Cronbach's Alpha) of 0.90. The…
ERIC Educational Resources Information Center
Floyd, Erin M.; Rayfield, Arista; Eyberg, Sheila M.; Riley III, Joseph L.
2004-01-01
This study examined the psychometric properties of the Sutter-Eyberg Student Behavior Inventory (SESBI) in a rural sample of children and adolescents. Thirty-eight 5th- through 12th-grade teachers completed the SESBI on 726 children in their classrooms. High Cronbach's alphas supported the reliability of the SESBI scales in this population. Higher…
Rojas-Carrasco, Karmina Elena
2010-01-01
Anxiety is a normal response in everyday life, when a person has a crisis like to have an ill child, when normality is altered and it could become a mental pathology. The purpose was to obtain the validity and standardization of the STAI (State-Trait Anxiety Inventory) for parents who had a hospitalized child in an intensive care unit (ICU). The STAI was applied to a group of 120 mothers and 90 fathers who had a hospitalized child in the ICU in a pediatric hospital. The analysis consisted of the assessment of the structural properties of the test through the construct validity found in the factorial analysis with a varimax rotation by the principal component methods and reliability by the Cronbach's alpha. Adequate factorial burdens were obtained for both state and trait anxiety factors, initially proposed by the authors. The Cronbach's alpha coefficients in each subgroup and in the global were established over 0.83: so the percentiles also were reported. The structural validity was confirmed. In this way the inventory and new standards can be used with better reliability in this type of sampling in subsequent and different clinical research condition.
Creation and Validation of the Self-esteem/Self-image Female Sexuality (SESIFS) Questionnaire.
Lordello, Maria Co; Ambrogini, Carolina C; Fanganiello, Ana L; Embiruçu, Teresa R; Zaneti, Marina M; Veloso, Laise; Piccirillo, Livia B; Crude, Bianca L; Haidar, Mauro; Silva, Ivaldo
2014-01-01
Self-esteem and self-image are psychological aspects that affect sexual function. To validate a new measurement tool that correlates the concepts of self-esteem, self-image, and sexuality. A 20-question test (the self-esteem/self-image female sexuality [SESIFS] questionnaire) was created and tested on 208 women. Participants answered: Rosenberg's self-esteem scale, the female sexual quotient (FSQ), and the SESIFS questionnaire. Pearson's correlation coefficient was used to test concurrent validity of the SESIFS against Rosenberg's self-esteem scale and the FSQ. Reliability was tested using the Cronbach's alpha coefficient. The new questionnaire had a good overall reliability (Cronbach's alpha r = 0.862, p < 0.001), but the sexual domain scored lower than expected (r = 0.65). The validity was good: overall score r = 0.38, p < 0.001, self-esteem domain r = 0.32, p < 0.001, self-image domain r = 0.31, p < 0.001, sexual domain r = 0.29, p < 0.001. The SESIFS questionnaire has limitations in measuring the correlation among self-esteem, self-image, and sexuality domains. A new, revised version is being tested and will be presented in an upcoming publication.
Development and psychometric properties of the Inner Strength Scale.
Lundman, Berit; Viglund, Kerstin; Aléx, Lena; Jonsén, Elisabeth; Norberg, Astrid; Fischer, Regina Santamäki; Strandberg, Gunilla; Nygren, Björn
2011-10-01
Four dimensions of inner strength were previously identified in a meta-theoretical analysis: firmness, creativity, connectedness, and flexibility. The aim of this study was to develop an Inner Strength Scale (ISS) based on those four dimensions and to evaluate its psychometric properties. An initial version of ISS was distributed for validation purpose with the Rosenberg Self-Esteem Scale, the resilience scale, and the sense of Coherence Scale. A convenience sample of 391 adults, aged 19-90 years participated. Principal component analysis (PCA) and confirmatory factor analysis (CFA) were used in the process of exploring, evaluating, and reducing the 63-item ISS to the 20-item ISS. Cronbach's alpha and test-retest were used to measure reliability. CFA showed satisfactory goodness-of-fit for the 20-item ISS. The analysis supported a fourfactor solution explaining 51% of the variance. Cronbach's alpha on the 20-item ISS was 0.86, and the test-retest showed stability over time (r=0.79). The ISS was found to be a valid and reliable instrument for capturing a multifaceted understanding of inner strength. Further tests of psychometric properties of the ISS will be performed in forthcoming studies. Copyright © 2011 Elsevier Ltd. All rights reserved.
García-Inzunza, Jaime A; Valles-Medina, Ana M; Muñoz, Fátima A; Delgadillo-Ramos, Guadalupe; Compean-Ortiz, Lidia G
2015-07-01
To 1) translate / transculturally adapt the original (English-language) combined Foot Care Confidence Scale / Foot-Care Behavior instrument (FCCS-FCB) to produce a Mexican-Spanish version and 2) determine its validity and reliability in a population with diabetes in Tijuana, Mexico. The original FCCS-FCB was translated (and back-translated), the content validated (by a group of health professional experts), and the instrument applied to 304 patients 23-78 years old in diabetes support groups in Tijuana, Mexico. Internal consistency for the study constructs ("self-efficacy," and risk / preventive foot self-care behaviors) was measured using Cronbach's alpha. The constructs were validated using principal component factor analysis. The Cronbach's alpha values for internal consistency were 0.782 for self-efficacy and 0.505 for behaviors. Based on the analysis, two factors explained 49.1% of the total variance for self-efficacy, and six factors explained 57.7% of the total variance for behaviors. The results were consistent with those for the original (English) version of the FCCS-FCB. The Mexican version of the FCCS-FCB is a reliable and valid instrument recommended for use with Mexican-Spanish-speaking patients with diabetes.
[A self administered survey to assess bullying in schools].
Lecannelier, Felipe; Varela, Jorge; Rodríguez, Jorge; Hoffmann, Marianela; Flores, Fernanda; Ascanio, Lorena
2011-04-01
Bullying is common in schools and has negative consequences. It can be assessed using a self-reported instrument. To validate a Spanish self-reporting tool called "Survey of High School Bullying Abuse of Power" (MIAP). The instrument has 13 questions, of which 7 are multiple choice, rendering a total of 49 items. It was applied to 2.341 children of seventh and eighth grade attending private, subsidized and municipal schools in the city of Concepción, Chile. Expert judge analysis and estimated reliability using the Cronbach Alpha were used to validate the survey. The instrument obtained a Cronbach Alpha coefficient of 0.8892, classified as good. This analysis generated four scales that explained 30.9% of the variance. They were called "Witness Bullying" with 18 items, accounting for 11.4% of the variance, "Bullying Victim" with 12 items, accounting for 7.5% of the variance, "Bullying Perpetrator and Severe bullying Victim", with 10 items explaining 6.4% of the variance and "Aggressor Bullying" with 6 items accounting for 5.7% of the variance. The MIAP can recognize four basic factors that facilitate the analysis and understanding of bullying, with good levels of reliability and validity. The remaining questions also deliver valuable information.
Demetrovics, Zsolt; Szeredi, Beatrix; Rózsa, Sándor
2008-05-01
Despite the fact that more and more clinical case studies and research reports have been published on the increasing problem of Internet addiction, no generally accepted standardized tool is available to measure problematic Internet use or Internet addiction. The aim of our study was to create such a questionnaire. On the basis of earlier studies and our previous experience withYoung's (1998a) Internet Addiction Test, initially, we created a 30-item questionnaire, which was assessed together with other questions regarding participants' Internet use. Data were collected online from 1,037 persons (54.1% of them male; mean age, 23.3 years; SD, 9.1). As a result of reliability analysis and factor analysis, we reduced the number of items to 18 and created the Problematic Internet Use Questionnaire (PIUQ) containing three subscales: obsession, neglect, and control disorder. Cronbach's alpha of the PIUQ is .87 (Cronbach's alpha of the subscales is .85, .74, and .76, respectively). The test-retest correlation of the PIUQ is .90. The PIUQ proved to be a reliable measurement for assessing the extent of problems caused by the "misuse" of the Internet; however, further analysis is needed.
Development of cultural belief scales for mammography screening.
Russell, Kathleen M; Champion, Victoria L; Perkins, Susan M
2003-01-01
To develop instruments to measure culturally related variables that may influence mammography screening behaviors in African American women. Instrumentation methodology. Community organizations and public housing in the Indianapolis, IN, area. 111 African American women with a mean age of 60.2 years and 64 Caucasian women with a mean age of 60 years. After item development, scales were administered. Data were analyzed by factor analysis, item analysis via internal consistency reliability using Cronbach's alpha, and independent t tests and logistic regression analysis to test theoretical relationships. Personal space preferences, health temporal orientation, and perceived personal control. Space items were factored into interpersonal and physical scales. Temporal orientation items were loaded on one factor, creating a one-dimensional scale. Control items were factored into internal and external control scales. Cronbach's alpha coefficients for the scales ranged from 0.76-0.88. Interpersonal space preference, health temporal orientation, and perceived internal control scales each were predictive of mammography screening adherence. The three tested scales were reliable and valid. Scales, on average, did not differ between African American and Caucasian populations. These scales may be useful in future investigations aimed at increasing mammography screening in African American and Caucasian women.
Determining the Appropriateness of the "What If" Situations Test (WIST) with Turkish Pre-Schoolers.
Citak Tunc, Gulseren; Gorak, Gulay; Ozyazicioglu, Nurcan; Ak, Bedriye; Isil, Ozlem; Vural, Pinar
2018-04-01
Measurement instruments are needed to assess the child's sexual abuse prevention program. The purpose of the study was to determine the reliability and validity of the WIST (What If Situations Test) for Turkish culture. Participants were children of the 3-6 age group attending pre-school education institutions and the sample size was identified by means of a power analysis. Seventy children were identified as the sample with 0.85 power and 0.05 type I error according to the power analysis. Language validity, content validity, internal validity coefficient (Cronbach alpha coefficient), and test-retest analyses were conducted in terms of validity and reliability in the scope of efforts for adaptation to Turkish culture. Firstly, Kendall W = 0.83 was the score for the expert opinions concerning the content validity of the language validity scale. It was found that the Cronbach alpha coefficients were between 0.68 and 0.90 for the scale sub-dimensions of appropriate and inappropriate recognition, saying, doing, telling, and reporting. The test-retest reliability of the scale was found to be r = 0.89 and the test-retest reliabilities for the sub-dimensions (appropriate recognition, inappropriate recognition, say skills, do skills, tell skills, and reporting skills) were between r = 0.48 and r = 0.92. The test-retest reliability for the Personal Safety Questionnaire (PSQ), as having complimentary items to the WIST, was found to be r = 0.82. The reliability and validity analysis of the 'What If' Situations Test (WIST), used to evaluate pre-schoolers' skills regarding self-protection against sexual abuse, showed that the Test's adaptation to Turkish culture was reliable and valid.
Soleimani, Mohammad Ali; Bahrami, Nasim; Yaghoobzadeh, Ameneh; Banihashemi, Hedieh; Nia, Hamid Sharif; Haghdoost, Ali Akbar
2016-01-01
Due to increasing recognition of the importance of death anxiety for understanding human nature, it is important that researchers who investigate death anxiety have reliable and valid methodology to measure. The purpose of this study was to evaluate the validity and reliability of the Persian version of Templer Death Anxiety Scale (TDAS) in family caregivers of cancer patients. A sample of 326 caregivers of cancer patients completed a 15-item questionnaire. Principal components analysis (PCA) followed by a varimax rotation was used to assess factor structure of the DAS. The construct validity of the scale was assessed using exploratory and confirmatory factor analyses. Convergent and discriminant validity were also examined. Reliability was assessed with Cronbach's alpha coefficients and construction reliability. Based on the results of the PCA and consideration of the meaning of our items, a three-factor solution, explaining 60.38% of the variance, was identified. A confirmatory factor analysis (CFA) then supported the adequacy of the three-domain structure of the DAS. Goodness-of-fit indices showed an acceptable fit overall with the full model {χ(2)(df) = 262.32 (61), χ(2)/df = 2.04 [adjusted goodness of fit index (AGFI) = 0.922, parsimonious comparative fit index (PCFI) = 0.703, normed fit Index (NFI) = 0.912, CMIN/DF = 2.048, root mean square error of approximation (RMSEA) = 0.055]}. Convergent and discriminant validity were shown with construct fulfilled. The Cronbach's alpha and construct reliability were greater than 0.70. The findings show that the Persian version of the TDAS has a three-factor structure and acceptable validity and reliability.
Soleimani, Mohammad Ali; Pahlevan Sharif, Saeed; Allen, Kelly A; Yaghoobzadeh, Ameneh; Sharif Nia, Hamid; Gorgulu, Ozkan
2017-12-01
The purpose of this study was to assess the psychometric properties of the Persian version of Spiritual Well-Being Scale (SWBS) in patients with acute myocardial infarction. A multisite, cross-sectional survey was employed to determine the instrument's reliability (Cronbach's α and construct reliability) and validity (face, content, and construct). Using systematic sampling of adult outpatients at primary care clinic sites in the Qazvin City, Iran (N = 300), it was found that the Cronbach's alpha and construct reliability of both factors associated with the SWBS were above 0.7. The construct validity of the scale was determined using exploratory factor analysis. The findings supported two factors: relation with God and relation with life. Further investigation through confirmatory factor analysis (eigenvalues of greater than one) confirmed a third factor construct associated with the SWBS. A total of 50.65 % of the variance were explained by these three factors. The overall findings of the study demonstrated that the SWBS is a valid and reliable instrument that has potential utility in future research and clinical practice settings.
Translation and validation of the Malay version of the Stroke Knowledge Test.
Sowtali, Siti Noorkhairina; Yusoff, Dariah Mohd; Harith, Sakinah; Mohamed, Monniaty
2016-04-01
To date, there is a lack of published studies on assessment tools to evaluate the effectiveness of stroke education programs. This study developed and validated the Malay language version of the Stroke Knowledge Test research instrument. This study involved translation, validity, and reliability phases. The instrument underwent backward and forward translation of the English version into the Malay language. Nine experts reviewed the content for consistency, clarity, difficulty, and suitability for inclusion. Perceived usefulness and utilization were obtained from experts' opinions. Later, face validity assessment was conducted with 10 stroke patients to determine appropriateness of sentences and grammar used. A pilot study was conducted with 41 stroke patients to determine the item analysis and reliability of the translated instrument using the Kuder Richardson 20 or Cronbach's alpha. The final Malay version Stroke Knowledge Test included 20 items with good content coverage, acceptable item properties, and positive expert review ratings. Psychometric investigations suggest that Malay version Stroke Knowledge Test had moderate reliability with Kuder Richardson 20 or Cronbach's alpha of 0.58. Improvement is required for Stroke Knowledge Test items with unacceptable difficulty indices. Overall, the average rating of perceived usefulness and perceived utility of the instruments were both 72.7%, suggesting that reviewers were likely to use the instruments in their facilities. Malay version Stroke Knowledge Test was a valid and reliable tool to assess educational needs and to evaluate stroke knowledge among participants of group-based stroke education programs in Malaysia.
The Cardiff Acne Disability Index (CADI): linguistic and cultural validation in Serbian.
Jankovic, Slavenka; Vukicevic, Jelica; Djordjevic, Sanja; Jankovic, Janko; Marinkovic, Jelena; Basra, Mohammad K A
2013-02-01
The aims of this study were to translate the Cardiff Acne Disability Index (CADI) into Serbian and to assess its validity and reliability in Serbian acne patients. The CADI was translated and linguistically validated into Serbian according to published guidelines. This version of CADI, along with the Serbian version of Children's Dermatology Life Quality Index (CDLQI) and a short demographic questionnaire, was administrated to a cohort of secondary school pupils. The Global Acne Grading Score was used to measure the clinical severity of acne. The internal consistency reliability of the Serbian version of CADI was assessed by Cronbach's alpha coefficient while its concurrent validity was assessed by Spearman's correlation coefficient. Construct validity was examined by factor analysis. A total of 465 pupils completed questionnaires. Self-reported acne was present in 76% of pupils (353/465). The Serbian version of CADI showed high internal consistency reliability (Cronbach's alpha coefficient = 0.79). The mean item-total correlation coefficient was 0.74 with a range of 0.53-0.81. The concurrent validity of the scale was supported by a moderate but highly significant correlation with the CDLQI (Spearman's rho = 0.66; P < 0.001). Factor analysis revealed the presence of two dimensions underlying the factor structure of the scale. The Serbian version of the CADI is a reliable, valid, and valuable tool for assessing the impact of acne on the quality of life of Serbian-speaking patients.
Simões, Maria do Socorro Mp; Garcia, Isabel Ff; Costa, Lucíola da Cm; Lunardi, Adriana C
2018-05-01
The Life-Space Assessment (LSA) assesses mobility from the spaces that older adults go, and how often and how independent they move. Despite its increased use, LSA measurement properties remain unclear. The aim of the present study was to analyze the content validity, reliability, construct validity and interpretability of the LSA for Brazilian community-dwelling older adults. In this clinimetric study we analyzed the measurement properties (content validity, reliability, construct validity and interpretability) of the LSA administered to 80 Brazilian community-dwelling older adults. Reliability was analyzed by Cronbach's alpha (internal consistency), intraclass correlation coefficients and 95% confidence interval (reproducibility), and standard error of measurement (measurement error). Construct validity was analyzed by Pearson's correlations between the LSA and accelerometry (time in inactivity and moderate-to-vigorous activities), and interpretability was analyzed by determination of the minimal detectable change, and floor and ceiling effects. The LSA met the criteria for content validity. The Cronbach's alpha was 0.92, intraclass correlation coefficient was 0.97 (95% confidence interval 0.95-0.98) and standard error of measurement was 4.12. The LSA showed convergence with accelerometry (negative correlation with time in inactivity and positive correlation with time in moderate to vigorous activities), the minimal detectable change was 0.36 and we observed no floor or ceiling effects. The LSA showed adequate reliability, validity and interpretability for life-space mobility assessment of Brazilian community-dwelling older adults. Geriatr Gerontol Int 2018; 18: 783-789. © 2018 Japan Geriatrics Society.
Gupta, Aayush; Sharma, Yugal K; Dash, K; Verma, Sampurna
2015-01-01
Acne vulgaris is known to impair many aspects of the quality of life (QoL) of its patients. To translate the Cardiff Acne Disability Index (CADI) from English into Hindi and to assess its validity and reliability in Hindi speaking patients with acne from India. Hindi version of CADI, translated and linguistically validated as per published international guidelines, along with a previously translated Hindi version of dermatology life quality index (DLQI) and a demographic questionnaire were administered to acne patients. The internal consistency reliability of the Hindi version of CADI and its concurrent validity were assessed by Cronbach's alpha co-efficient and Spearman's correlation co-efficient respectively. Construct validity was examined by factor analysis. Statistical analysis was carried out using the Statistical Package for the Social Sciences (SPSS) version 20 (SPSS Inc., Chicago, IL, USA) for Windows. One hundred Hindi speaking patients with various grades of acne participated in the study. Hindi version of CADI showed high internal consistency reliability (Cronbach's alpha co-efficient = 0.722). Mean item-to-total correlation co-efficient ranged from 0.502 to 0.760. Concurrent validity of the scale was supported by a significant correlation with the Hindi DLQI. Factor analysis revealed the presence of two dimensions underlying the factor structure of the scale. Hindi CADI is equivalent to the original English version and constitutes a reliable and valid tool for clinical assessment of the impact of acne on QoL.
Healthy eating opinion survey for individuals at risk for cardiovascular disease.
Mark, Amy E; Riley, Dana L; McDonnell, Lisa A; Pipe, Andrew L; Reid, Robert D
2014-08-01
To develop and evaluate the validity and reliability of a questionnaire to measure intentions and beliefs about healthy eating in individuals at risk for coronary heart disease. The Healthy Eating Opinion Survey was developed using the theory of planned behavior. An open-ended elicitation questionnaire was administered to 21 participants, and a 46-item questionnaire was developed for further testing. Test-retest reliability of each question on the survey was assessed by calculating the correlation coefficients between the responses over a 2- week period in 17 participants. Internal consistency was assessed using Cronbach's alpha, and factor analysis was used to assess the construct validity of the questionnaire in a sample of 388 participants. The responses to the elicitation questions were used to develop behavioral beliefs, normative beliefs, and control beliefs questions for the final questionnaire. Test-retest reliability ranged from 0.22-0.90, with the majority (89%) of correlations being moderate to strong. Internal consistency was good, with Cronbach's alpha ranging from 0.74-0.92. All intentions questions loaded onto a single factor; attitude questions loaded onto two factors; subjective norm questions loaded onto two factors; perceived behavioral control questions loaded onto one factor; behavioral beliefs questions loaded onto one factor; normative beliefs questions loaded onto one factor; and control beliefs questions loaded onto one factor. The questionnaire was found to be a reliable, valid questionnaire to assess beliefs and intentions toward eating a healthy diet in individuals at risk for coronary heart disease.
Park, Yu Kyung; Ju, Hyeon Ok; Na, Hunjoo
2016-02-01
The Perinatal Post-Traumatic Stress Disorder Questionnaire (PPQ) was designed to measure post-traumatic symptoms related to childbirth and symptoms during postnatal period. The purpose of this study was to develop a translated Korean version of the PPQ and to evaluate reliability and validity of the Korean PPQ. Participants were 196 mothers at one to 18 months after giving childbirth and data were collected through e-mails. The PPQ was translated into Korean using translation guideline from World Health Organization. For this study Cronbach's alpha and split-half reliability were used to evaluate the reliability of the PPQ. Exploratory Factor Analysis (EFA), Confirmatory Factor Analysis (CFA), and known-group validity were conducted to examine construct validity. Correlations of the PPQ with Impact of Event Scale (IES), Beck Depression Inventory II (BDI-II), and Beck Anxiety Inventory (BAI) were used to test a criterion validity of the PPQ. Cronbach's alpha and Spearman-Brown split-half correlation coefficient were 0.91 and 0.77, respectively. EFA identified a 3-factor solution including arousal, avoidance, and intrusion factors and CFA revealed the strongest support for the 3-factor model. The correlations of the PPQ with IES, BDI-II, and BAI were .99, .60, and .72, respectively, pointing to criterion validity of a high level. The Korean version PPQ is a useful tool for screening and assessing mothers' experiencing emotional distress related to child birth and during the postnatal period. The PPQ also reflects Post Traumatic Stress Disorder's diagnostic standards well.
Cañón-Montañez, Wilson; Oróstegui-Arenas, Myriam
2015-01-01
To determine the reliability (internal consistency, inter-rater reproducibility and level of agreement) of nursing outcome: "Knowledge: cardiac disease management (1830)" of the version published in Spanish, in outpatients with heart failure. A reliability study was conducted on 116 outpatients with heart failure. Six indicators of nursing outcome were operationalized. All participants were assessed simultaneously by two evaluators. Three evaluation periods were defined: initial (at baseline), final (a month later), and follow-up (two months later). Internal consistency by Cronbach alpha coefficient, inter-rater reproducibility with intraclass correlation coefficient of reproducibility or agreement and level agreement using the 95% limits of Bland and Altman. Cronbach's alpha was 0.83 (95% CI: 0.77 - 0.89) in the final evaluation, and follow-up values of 0.85 (95% CI: 0.82-0.89) and 0.83 (95% CI: 0.78 - 0.88) were found for the first and second evaluator, respectively. The intraclass correlation coefficient showed values greater 0.9 in the three evaluation periods in both the random and mixed model. The Bland-Altman 95% limits of agreement were close to zero in the three evaluations performed. The questionnaire operationalized to assess the nursing outcome: "Knowledge: cardiac disease management (1830)" in its Spanish version, is a reliable method to measure skills and knowledge in outpatients with heart failure in the Colombian context. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.
Mraity, Hussien A A B; England, Andrew; Cassidy, Simon; Eachus, Peter; Dominguez, Alejandro; Hogg, Peter
2016-01-01
The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality.
England, Andrew; Cassidy, Simon; Eachus, Peter; Dominguez, Alejandro; Hogg, Peter
2016-01-01
Objective: The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. Methods: Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. Results: A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). Conclusion: This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. Advances in knowledge: This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality. PMID:26943836
Reliable scar scoring system to assess photographs of burn patients.
Mecott, Gabriel A; Finnerty, Celeste C; Herndon, David N; Al-Mousawi, Ahmed M; Branski, Ludwik K; Hegde, Sachin; Kraft, Robert; Williams, Felicia N; Maldonado, Susana A; Rivero, Haidy G; Rodriguez-Escobar, Noe; Jeschke, Marc G
2015-12-01
Several scar-scoring scales exist to clinically monitor burn scar development and maturation. Although scoring scars through direct clinical examination is ideal, scars must sometimes be scored from photographs. No scar scale currently exists for the latter purpose. We modified a previously described scar scale (Yeong et al., J Burn Care Rehabil 1997) and tested the reliability of this new scale in assessing burn scars from photographs. The new scale consisted of three parameters as follows: scar height, surface appearance, and color mismatch. Each parameter was assigned a score of 1 (best) to 4 (worst), generating a total score of 3-12. Five physicians with burns training scored 120 representative photographs using the original and modified scales. Reliability was analyzed using coefficient of agreement, Cronbach alpha, intraclass correlation coefficient, variance, and coefficient of variance. Analysis of variance was performed using the Kruskal-Wallis test. Color mismatch and scar height scores were validated by analyzing actual height and color differences. The intraclass correlation coefficient, the coefficient of agreement, and Cronbach alpha were higher for the modified scale than those of the original scale. The original scale produced more variance than that in the modified scale. Subanalysis demonstrated that, for all categories, the modified scale had greater correlation and reliability than the original scale. The correlation between color mismatch scores and actual color differences was 0.84 and between scar height scores and actual height was 0.81. The modified scar scale is a simple, reliable, and useful scale for evaluating photographs of burn patients. Copyright © 2015 Elsevier Inc. All rights reserved.
Abou Samra, Haifa; McGrath, Jacqueline M; Estes, Tracy
2013-06-01
No instrument exists that measures student perceptions of the faculty role. Such a measure is necessary to evaluate the efficacy of interventions aimed at attracting students to the faculty career path. We developed the Nurse Educator Scale (NES). The initial scale items were generated using the social cognitive career theory (SCCT) constructs and were reviewed by an expert panel to ensure content validity. Exploratory factor analysis was used. The optimized 25-item, 7-point Likert scale has a Cronbach's alpha reliability coefficient of 0.85, with a total variance of 42%. The underlying factor structure supported three defining characteristics congruent with SCCT: outcome expectations (alpha = 0.79), relevant knowledge (alpha = 0.67), and social influence (alpha = 0.80). A stand-alone, item-measuring goal setting was also supported. The NES provides a valid and reliable measure of students' intentions and motivations to pursue a future career as a nurse educator or scientist. Copyright 2013, SLACK Incorporated.
Reliable assessment of laparoscopic performance in the operating room using videotape analysis.
Chang, Lily; Hogle, Nancy J; Moore, Brianna B; Graham, Mark J; Sinanan, Mika N; Bailey, Robert; Fowler, Dennis L
2007-06-01
The Global Operative Assessment of Laparoscopic Skills (GOALS) is a valid assessment tool for objectively evaluating the technical performance of laparoscopic skills in surgery residents. We hypothesized that GOALS would reliably differentiate between an experienced (expert) and an inexperienced (novice) laparoscopic surgeon (construct validity) based on a blinded videotape review of a laparoscopic cholecystectomy procedure. Ten board-certified surgeons actively engaged in the practice and teaching of laparoscopy reviewed and evaluated the videotaped operative performance of one novice and one expert laparoscopic surgeon using GOALS. Each reviewer recorded a score for both the expert and the novice videotape reviews in each of the 5 domains in GOALS (depth perception, bimanual dexterity, efficiency, tissue handling, and overall competence). The scores for the expert and the novice were compared and statistically analyzed using single-factor analysis of variance (ANOVA). The expert scored significantly higher than the novice did in the domains of depth perception (p = .005), bimanual dexterity (p = .001), efficiency (p = .001), and overall competence ( p = .001). Interrater reliability for the reviewers of the novice tape was Cronbach alpha = .93 and the expert tape was Cronbach alpha = .87. There was no difference between the two for tissue handling. The Global Operative Assessment of Laparoscopic Skills is a valid, objective assessment tool for evaluating technical surgical performance when used to blindly evaluate an intraoperative videotape recording of a laparoscopic procedure.
[Validity and Reliability of Korean Version of the Spiritual Care Competence Scale].
Chung, Mi Ja; Park, Youngrye; Eun, Young
2016-12-01
The aim of this study was to examine the validity and reliability of the Korean Version of the Spiritual Care Competence Scale (K-SCCS). A cross-sectional study design was used. The K-SCCS consisted of 26 questions to measure spiritual care competence of nurses. Participants, 228 nurses who had more than 3 years'experience as a nurse, completed the survey. Confirmatory factor analysis was used to examine the construct validity and correlations of K-SCCS and spiritual well-being (SWB) were used to examine the criterion validity of K-SCCS. Cronbach's alpha was used to test internal consistency. The construct and the criterion-related validity of K-SCCS were supported as measures of spiritual care competence. Cronbach's alpha was .95. Factor loadings of the 26 questions ranged from .60 to .96. Construct validity of K-SCCS was verified by confirmatory factor analysis (RMSEA=.08, CFI=.90, NFI=.85). Criterion validity compared to the SWB showed significant correlation (r=.44, p<.001). The findings suggest that K-SCCS serves as an appropriate measure of spiritual care competence with validity and reliability. However, further study is needed to retest the verification of the factor analysis related to factor 2 (professionalisation and improving the quality of spiritual care) and factor 3 (personal support and patient counseling). Therefore, we recommend using the total score without distinguishing subscales.
Skarzynski, Piotr H; Raj-Koziak, Danuta; J Rajchel, Joanna; Pilka, Adam; Wlodarczyk, Andrzej W; Skarzynski, Henryk
2017-10-01
To describe how the Tinnitus Handicap Inventory (THI) was translated into Polish (THI-POL) and to present psychometric data on how well it performed in a clinical population of tinnitus sufferers. The original version of THI was adapted into Polish. The reliability of THI-POL was investigated using test-retest, Cronbach's alpha, endorsement rate and item-total correlation. Construct validity and convergent validity were also assessed based on confirmatory factor analysis, inter-item correlation and Pearson product-moment correlations using subscale A (Tinnitus) of the Tinnitus and Hearing Survey (THS-POL); divergent validity was checked using subscale B (Hearing) of THS-POL. A group of 167 adults filled in THI-POL twice over their three-day hospitalisation period. Test-retest reliability for the total THI-POL scores was strong (r = 0.91). Cronbach's alpha coefficient for the total score was high (r = 0.95), confirming the questionnaire's stability. Confirmatory factor analysis (CFA) and inter-item correlation did not confirm the three-factor model. Convergent validity from the Tinnitus subscale of THS showed a positive strong (r = 0.75) correlation. Divergent validity showed only a moderate correlation. All analyses were statistically significant (p < 0.01). THI-POL is a valid and reliable self-administered tool, which allows the overall tinnitus handicap of Polish-speaking patients to be effectively assessed.
Psychometric evaluation of the Arabic language person-centred climate questionnaire-staff version.
Aljuaid, Mohammed; Elmontsri, Mustafa; Edvardsson, David; Rawaf, Salman; Majeed, Azeem
2018-05-01
To evaluate the psychometric properties of the Arabic language person-centred climate questionnaire-staff version. There have been increasing calls for a person-centred rather than a disease-centred approach to health care. A limited number of tools measure the extent to which care is delivered in a person-centred manner, and none of these tools have been validated for us in Arab settings. The validated form of the person-centred climate questionnaire-staff version was translated into Arabic and distributed to 152 health care staff in teaching and non-teaching hospitals in Saudi Arabia. Statistical estimates of validity and reliability were used for psychometric evaluation. Items on the Arabic form of the person-centred climate questionnaire-staff version had high reliability (Cronbach's alpha .98). Cronbach's alpha values for the three sub-scales (safety, everydayness and community), were .96, .97 and .95 respectively. Internal consistency was also high and measures of validity were very good. Arabic form of the person-centred climate questionnaire-staff version provides a valid and reliable way to measure the degree of perceived person-centredness. The tool can be used for comparing levels of person-centredness between wards, units, and public and private hospitals. The tool can also be used to measure the extent of person-centredness in health care settings in other Arab countries. © 2017 John Wiley & Sons Ltd.
Judging in Rhythmic Gymnastics at Different Levels of Performance.
Leandro, Catarina; Ávila-Carvalho, Lurdes; Sierra-Palmeiro, Elena; Bobo-Arce, Marta
2017-12-01
This study aimed to analyse the quality of difficulty judging in rhythmic gymnastics, at different levels of performance. The sample consisted of 1152 difficulty scores concerning 288 individual routines, performed in the World Championships in 2013. The data were analysed using the mean absolute judge deviation from the final difficulty score, a Cronbach's alpha coefficient and intra-class correlations, for consistency and reliability assessment. For validity assessment, mean deviations of judges' difficulty scores, the Kendall's coefficient of concordance W and ANOVA eta-squared values were calculated. Overall, the results in terms of consistency (Cronbach's alpha mostly above 0.90) and reliability (intra-class correlations for single and average measures above 0.70 and 0.90, respectively) were satisfactory, in the first and third parts of the ranking on all apparatus. The medium level gymnasts, those in the second part of the ranking, had inferior reliability indices and highest score dispersion. In this part, the minimum of corrected item-total correlation of individual judges was 0.55, with most values well below, and the matrix for between-judge correlations identified remarkable inferior correlations. These findings suggest that the quality of difficulty judging in rhythmic gymnastics may be compromised at certain levels of performance. In future, special attention should be paid to the judging analysis of the medium level gymnasts, as well as the Code of Points applicability at this level.
Cecchetto, Fátima H; Pellanda, Lucia C
2014-01-01
To develop and analyze the reliability and validity of a questionnaire on the knowledge of healthy habits and risk factors for cardiovascular disease (CARDIOKID) to be used in schoolchildren. The study included 145 children aged 7 to 11 years. The measured factors were the knowledge of healthy habits and risk factors for cardiovascular disease. Cronbach's alpha and intra-class correlation coefficient (ICC) were used to verify reliability, and exploratory factor analysis was used to assess the validity of the questionnaire. The sample consisted of 60% females and 40% males. In factorial analysis, the Kaiser-Meyer-Olkin (KMO) test result was measures of sampling adequacy (MSA)=0.81 and Bartlett's test of sphericity was X(2)=(66)=458.64 (p<0.001). In the factorial analysis with varimax rotation, two dimensions were defined. The "healthy habits" dimension was composed of five factors (ICC=0.87 and α=0.93) and the "cardiovascular risk factors" dimension was composed of seven factors (ICC=0.83 and α=0.91). In the individual factor analysis, Cronbach's alphas were between 0.93 and 0.91. Total variance was 46.87%. There were no significant differences between test and retest applications. The questionnaire presented satisfactory validity and reliability (internal consistency and reproducibility), allowing for its use in children. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Sexual behavioral abstine HIV/AIDS questionnaire: Validation study of an Iranian questionnaire.
Najarkolaei, Fatemeh Rahmati; Niknami, Shamsaddin; Shokravi, Farkhondeh Amin; Tavafian, Sedigheh Sadat; Fesharaki, Mohammad Gholami; Jafari, Mohammad Reza
2014-01-01
This study was designed to assess the validity and reliability of the designed sexual, behavioral abstinence, and avoidance of high-risk situation questionnaire (SBAHAQ), with an aim to construct an appropriate development tool in the Iranian population. A descriptive-analytic study was conducted among female undergraduate students of Tehran University, who were selected through cluster random sampling. After reviewing the questionnaires and investigating face and content validity, internal consistency of the questionnaire was assessed by Cronbach's alpha. Explanatory and confirmatory factor analysis was conducted using SPSS and AMOS 16 Software, respectively. The sample consisted of 348 female university students with a mean age of 20.69 ± 1.63 years. The content validity ratio (CVR) coefficient was 0.85 and the reliability of each section of the questionnaire was as follows: Perceived benefit (PB; 0.87), behavioral intention (BI; 0.77), and self-efficacy (SE; 0.85) (Cronbach's alpha totally was 0.83). Explanatory factor analysis showed three factors, including SE, PB, and BI, with the total variance of 61% and Kaiser-Meyer-Olkin (KMO) index of 88%. These factors were also confirmed by confirmatory factor analysis [adjusted goodness of fitness index (AGFI) = 0.939, root mean square error of approximation (RMSEA) = 0.039]. This study showed the designed questionnaire provided adequate construct validity and reliability, and could be adequately used to measure sexual abstinence and avoidance of high-risk situations among female students.
Reliability and Validity of the Physical Education Activities Scale.
Thomason, Diane L; Feng, Du
2016-06-01
Measuring adolescent perceptions of physical education (PE) activities is necessary in understanding determinants of school PE activity participation. This study assessed reliability and validity of the Physical Education Activities Scale (PEAS), a 41-item visual analog scale measuring high school adolescent perceptions of school PE activity participation. Adolescents (N = 529) from the Pacific Northwest aged 15-19 in grades 9-12 participated in the study. Construct validity was assessed using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). Measurement invariance across sex groups was tested by multiple-group CFA. Internal consistency reliability was analyzed using Cronbach's alpha. Inter-subscale correlations (Pearson's r) were calculated for latent factors and observed subscale scores. Exploratory factor analysis suggested a 3-factor solution explaining 43.4% of the total variance. Confirmatory factor analysis showed the 3-factor model fit the data adequately (comparative fit index [CFI] = 0.90, Tucker-Lewis index [TLI] = 0.89, root mean squared error of approximation [RMSEA] = 0.063). Factorial invariance was supported. Cronbach's alpha of the total PEAS was α = 0.92, and for subscales α ranged from 0.65 to 0.92. Independent t-tests showed significantly higher mean scores for boys than girls on the total scale and all subscales. Findings provide psychometric support for using the PEAS for examining adolescent's psychosocial and environmental perceptions to participating in PE activities. © 2016, American School Health Association.
Validity and cultural equivalence of the standard Greene Climacteric Scale in Hong Kong.
Chen, Run Qiu; Davis, Susan R; Wong, Chit Ming; Lam, Tai Hing
2010-01-01
The aim of this study was to translate the standard Greene Climacteric Scale (GCS) and a urogenital symptom scale into colloquial Chinese (Hong Kong) and test their validity and reliability in Hong Kong Chinese women. The scales were translated with standard techniques, and cross-cultural construct validity, internal consistency, test-retest reliability, and responsiveness were tested on samples of women aged 40 to 60 years recruited from the community. A total of 611 women, with mean (SD) age of 48.9 (5.3) years, provided completed scales for the study. Confirmatory factor analysis demonstrated construct validity of the translated standard GCS. The items were found to have good homogeneity in measuring the scale concepts (Cronbach alpha > 0.7). But the three-item urogenital scale had poor internal consistency (Cronbach alpha = 0.43), and a combination of this scale with the standard GCS resulted in a reduced model fit to the data. Test-retest reliability for the GCS was good on women recruited for a retest (n = 52). The translated GCS was found to be responsive to change over time (effect size, 0.59; n = 19). The Chinese (Hong Kong) version of the standard GCS is a valid and cultural-equivalent instrument. Our data do not support inclusion of the urogenital scale to the standard GCS. Measurement of urogenital symptoms is subject to further study.
Maroufizadeh, Saman; Zareiyan, Armin; Sigari, Naseh
2014-05-01
Asthma is a major public health problem in the world, and recent findings suggest that stress influences asthma and asthma morbidity. The 10-item Perceived Stress Scale (PSS-10) is one of the most frequently used instruments to measure psychological stress. This study was conducted to evaluate the psychometric properties of the Persian versions of the PSS-10 in adults with asthma. In this descriptive cross-sectional study as a methodological research, 106 asthmatic patients referring to several clinics in Sanandaj (western Iran) were selected through convenience sampling. The PSS-10 and the 21-item Depression anxiety and stress scale (DASS-21) were administrated to all patients. Cronbach's alpha was used to evaluate reliability of PSS-10, and confirmatory factor analysis (CFA) and convergent validity were used to evaluate its validity. The results of confirmatory factor analysis indicated that a two-factor structure of PSS-10 provided a good fit to data. The Cronbach's alpha coefficients for negative factor, positive factor and total score (PSS-10) were 0.86, 0.83, and 0.90, respectively. The PSS-10 was positively correlated with the DASS-21 and its subscales, indicating an acceptable convergent validity. Female asthmatic patients scored higher on PSS-10 in comparison with male asthmatic patients. The Persian version of PSS-10 is a valid and reliable instrument to measure perceived stress in adults with asthma.
The Work-Health-Check (WHC): a brief new tool for assessing psychosocial stress in the workplace.
Gadinger, M C; Schilling, O; Litaker, D; Fischer, J E
2012-01-01
Brief, psychometrically robust questionnaires assessing work-related psychosocial stressors are lacking. The purpose of the study is to evaluate the psychometric properties of a brief new questionnaire for assessing sources of work-related psychosocial stress. Managers, blue- and white-collar workers (n= 628 at measurement point one, n=459 at measurement point two), sampled from an online panel of a German marketing research institute. We either developed or identified appropriate items from existing questionnaires for ten scales, which are conceptually based in work stress models and reflected either work-related demands or resources. Factorial structure was evaluated by confirmatory factor analyses (CFA). Scale reliability was assessed by Cronbach's Alpha, and test-retest; correlations with work-related efforts demonstrated convergent and discriminant validity for the demand and resource scales, respectively. Scale correlations with health indicators tested criterion validity. All scales had satisfactory reliability (Cronbach's Alpha: 0.74-0.93, retest reliabilities: 0.66-0.81). CFA supported the anticipated factorial structure. Significant correlations between job-related efforts and demand scales (mean r=0.44) and non-significant correlations with the resource scales (mean r=0.07) suggested good convergent and discriminant validity, respectively. Scale correlations with health indicators demonstrated good criterion validity. The WHC appears to be a brief, psychometrically robust instrument for assessing work-related psychosocial stressors.
Fossati, Andrea; Somma, Antonella; Borroni, Serena; Markon, Kristian E; Krueger, Robert F
2017-07-01
To assess the reliability and construct validity of the Personality Inventory for DSM-5 Brief Form (PID-5-BF) among adolescents, 877 Italian high school students were administered the PID-5-BF. Participants were administered also the Measure of Disordered Personality Functioning (MDPF) as a criterion measure. In the full sample, Cronbach's alpha values for the PID-5-BF scales ranged from .59 (Detachment) to .77 (Psychoticism); in addition, all PID-5-BF scales showed mean interitem correlation values in the .22 to .40 range. Cronbach's alpha values for the PID-5-BF total score was .83 (mean interitem r = .16). Although 2-month test-retest reliability could be assessed only in a small ( n = 42) subsample of participants, all PID-5-BF scale scores showed adequate temporal stability, as indexed by intraclass r values ranging from .78 (Negative Affectivity) to .97 (Detachment), all ps <.001. Exploratory structural equation modeling analyses provided at least moderate support for the a priori model of PID-5-BF items. Multiple regression analyses showed that PID-5-BF scales predicted a nonnegligible amount of variance in MDPF Non-Cooperativeness, adjusted R 2 = .17, p < .001, and Non-Coping scales, adjusted R 2 = .32, p < .001. Similarly, the PID-5-BF total score was a significant predictor of both MDPF Non-Coping, and Non-Cooperativeness scales.
Validity and reliability of a pilot scale for assessment of multiple system atrophy symptoms.
Matsushima, Masaaki; Yabe, Ichiro; Takahashi, Ikuko; Hirotani, Makoto; Kano, Takahiro; Horiuchi, Kazuhiro; Houzen, Hideki; Sasaki, Hidenao
2017-01-01
Multiple system atrophy (MSA) is a rare progressive neurodegenerative disorder for which brief yet sensitive scale is required in order for use in clinical trials and general screening. We previously compared several scales for the assessment of MSA symptoms and devised an eight-item pilot scale with large standardized response mean [handwriting, finger taps, transfers, standing with feet together, turning trunk, turning 360°, gait, body sway]. The aim of the present study is to investigate the validity and reliability of a simple pilot scale for assessment of multiple system atrophy symptoms. Thirty-two patients with MSA (15 male/17 female; 20 cerebellar subtype [MSA-C]/12 parkinsonian subtype [MSA-P]) were prospectively registered between January 1, 2014 and February 28, 2015. Patients were evaluated by two independent raters using the Unified MSA Rating Scale (UMSARS), Scale for Assessment and Rating of Ataxia (SARA), and the pilot scale. Correlations between UMSARS, SARA, pilot scale scores, intraclass correlation coefficients (ICCs), and Cronbach's alpha coefficients were calculated. Pilot scale scores significantly correlated with scores for UMSARS Parts I, II, and IV as well as with SARA scores. Intra-rater and inter-rater ICCs and Cronbach's alpha coefficients remained high (> 0.94) for all measures. The results of the present study indicate the validity and reliability of the eight-item pilot scale, particularly for the assessment of symptoms in patients with early state multiple system atrophy.
Chinese adaptation and validation of the patellofemoral pain severity scale.
Cheung, Roy T H; Ngai, Shirley P C; Lam, Priscillia L; Chiu, Joseph K W; Fung, Eric Y H
2013-05-01
This study validated the Patellofemoral Pain Severity Scale translated into Chinese. The Chinese Patellofemoral Pain Severity Scale was translated from the original English version following standard forward and backward translation procedures recommended by the International Society for Pharmacoeconomics and Outcomes Research. The survey was then conducted in clinical settings by a questionnaire comprising the Chinese Patellofemoral Pain Severity Scale, Kujala Scale and Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index. Eighty-four Chinese reading patients with patellofemoral pain were recruited from physical therapy clinics. Internal consistency of the translated instrument was measured by Cronbach alpha. Convergent validity was examined by Spearman rank correlation coefficient (rho) tests by comparing its score with the validated Chinese version of the Kujala Scale and the WOMAC Osteoarthritis Index while the test-retest reliability was evaluated by administering the questionnaires twice. Cronbach alpha values of individual questions and their overall value were above 0.85. Strong association was found between the Chinese Patellofemoral Pain Severity Scale and the Kujala Scale (rho = -0.72, p < 0.001). Moderate correlation was also found between Chinese Patellofemoral Pain Severity Scale with the WOMAC Osteoarthritis Index (rho = 0.63, p < 0.001). Excellent test-retest reliability (Intraclass correlation coefficient = 0.98) was demonstrated. The Chinese translated version of the Patellofemoral Pain Severity Scale is a reliable and valid instrument for patients with patellofemoral pain.
Erhart, M; Hagquist, C; Auquier, P; Rajmil, L; Power, M; Ravens-Sieberer, U
2010-07-01
This study compares item reduction analysis based on classical test theory (maximizing Cronbach's alpha - approach A), with analysis based on the Rasch Partial Credit Model item-fit (approach B), as applied to children and adolescents' health-related quality of life (HRQoL) items. The reliability and structural, cross-cultural and known-group validity of the measures were examined. Within the European KIDSCREEN project, 3019 children and adolescents (8-18 years) from seven European countries answered 19 HRQoL items of the Physical Well-being dimension of a preliminary KIDSCREEN instrument. The Cronbach's alpha and corrected item total correlation (approach A) were compared with infit mean squares and the Q-index item-fit derived according to a partial credit model (approach B). Cross-cultural differential item functioning (DIF ordinal logistic regression approach), structural validity (confirmatory factor analysis and residual correlation) and relative validity (RV) for socio-demographic and health-related factors were calculated for approaches (A) and (B). Approach (A) led to the retention of 13 items, compared with 11 items with approach (B). The item overlap was 69% for (A) and 78% for (B). The correlation coefficient of the summated ratings was 0.93. The Cronbach's alpha was similar for both versions [0.86 (A); 0.85 (B)]. Both approaches selected some items that are not strictly unidimensional and items displaying DIF. RV ratios favoured (A) with regard to socio-demographic aspects. Approach (B) was superior in RV with regard to health-related aspects. Both types of item reduction analysis should be accompanied by additional analyses. Neither of the two approaches was universally superior with regard to cultural, structural and known-group validity. However, the results support the usability of the Rasch method for developing new HRQoL measures for children and adolescents.
Al-Eidan, Fahad; Baig, Lubna Ansari; Magzoub, Mohi-Eldin; Omair, Aamir
2016-04-01
To assess reliability and validity of evaluation tool using Haematology course as an example. The cross-sectional study was conducted at King Saud Bin Abdul Aziz University of Health Sciences, Riyadh, Saudi Arabia, in 2012, while data analysis was completed in 2013. The 27-item block evaluation instrument was developed by a multidisciplinary faculty after a comprehensive literature review. Validity of the questionnaire was confirmed using principal component analysis with varimax rotation and Kaiser normalisation. Identified factors were combined to get the internal consistency reliability of each factor. Student's t-test was used to compare mean ratings between male and female students for the faculty and block evaluation. Of the 116 subjects in the study, 80(69%) were males and 36(31%) were females. Reliability of the questionnaire was Cronbach's alpha 0.91. Factor analysis yielded a logically coherent 7 factor solution that explained 75% of the variation in the data. The factors were group dynamics in problem-based learning (alpha0.92), block administration (alpha 0.89), quality of objective structured clinical examination (alpha 0.86), block coordination (alpha 0.81), structure of problem-based learning (alpha 0.84), quality of written exam (alpha 0.91), and difficulty of exams (alpha0.41). Female students' opinion on depth of analysis and critical thinking was significantly higher than that of the males (p=0.03). The faculty evaluation tool used was found to be reliable, but its validity, as assessed through factor analysis, has to be interpreted with caution as the responders were less than the minimum required for factor analysis.
Ida, Mitsuru; Naito, Yusuke; Tanaka, Yuu; Matsunari, Yasunori; Inoue, Satoki; Kawaguchi, Masahiko
2017-08-01
The avoidance of postoperative functional disability is one of the most important concerns of patients facing surgery, but methods to evaluate disability have not been definitively established. The aim of our study was to evaluate the feasibility, reliability, and validity of the Japanese version of the 12-item World Health Organization Disability Assessment Schedule-2 (WHODAS 2.0-J) in preoperative patients. Individuals aged ≥55 years who were scheduled to undergo surgery in a tertiary-care hospital in Japan between April 2016 and September 2016 were eligible for enrolment in the study. All patients were assessed preoperatively using the WHODAS 2.0-J, the 8-Item Short Form (SF-8) questionnaire, and the Tokyo Metropolitan Institute of Gerontology Index (TMIG Index). The feasibility, reliability, and validity of WHODAS2.0-J were evaluated using response rate, Cronbach's alpha (a measure of reliability), and the correlation between the WHODAS 2.0-J and the SF-8 questionnaire and TMIG Index, respectively. A total of 934 patients were enrolled in the study during the study period, of whom 930 completed the WHODAS 2.0-J (response rate 99.5%) preoperatively. Reliability and validity were assessed in the 898 patients who completed all three assessment tools (WHODAS 2.0-J, SF-8 questionnaire, and TMIG Index) and for whom all demographic data were available. Cronbach's alpha was 0.92. The total score of the WHODAS 2.0-J showed a mild or moderate correlation with the SF-8 questionnaire and TMIG Index (r = -0.63 to -0.34). The WHODAS 2.0-J is a feasible, reliable, and valid instrument for evaluating preoperative functional disability in surgical patients.
Giezen, Hilde; Stevens, Martin; van den Akker-Scheek, Inge; Reininga, Inge H F
2017-01-01
The Copenhagen Hip And Groin Outcome Score (HAGOS) was developed to assess disease-specific consequences in young to middle-aged, physically active hip and/or groin patients. The study aimed to determine validity and reliability of the Dutch version of the HAGOS (HAGOS-NL) for middle-aged patients with hip complaints. To assess validity, 117 participants completed five questionnaires: HAGOS-NL, international Hip Outcome Tool (iHOT-12NL), Hip disability and Osteoarthritis Outcome Score (HOOS), RAND-36 Health Survey and Tegner activity scale. Structural validity was determined by conducting confirmatory factor analysis. Construct validity was analyzed by formulating predefined hypotheses regarding relationships between the HAGOS-NL and subscales of the iHOT-12NL, HOOS, RAND-36 and Tegner activity scale. The HAGOS-NL was filled out again by 67 patients to explore test-retest reliability. Reliability was assessed in terms of Cronbach's alpha, Intraclass Correlation Coefficient (ICC), Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC). The Bland and Altman method was used to explore absolute agreement. Factor analysis confirmed that the HAGOS-NL consists of six subscales. All hypotheses were confirmed, indicating good construct validity. Internal consistency was good, with Cronbach's alpha values ranging from 0.89 to 0.98. Test-retest reliability was considered good, with ICC values of 0.80 and higher. The SEM ranged from 6.6 to 12.3, and MDC at individual level from 18.3 to 34.1 and at group level from 2.3 to 4.4. Bland and Altman analyses showed no bias. The HAGOS-NL is a reliable and valid instrument for measuring pain, physical functioning and quality of life in middle-aged patients with hip complaints.
Validity and reliability of a Dutch version of the Foot and Ankle Ability Measure.
Weel, Hanneke; Zwiers, Ruben; Azim, Donija; Sierevelt, Inger N; Haverkamp, Daniel; van Dijk, C Niek; Kerkhoffs, Gino M M J
2016-04-01
The aim of the study was to develop a Dutch language version of the Foot and Ankle Ability Measure (FAAM) and evaluate its measurement properties according to the consensus-based standards for the selection of health measurement instruments (COSMIN) definitions. A forward-backward translation procedure was performed and subsequently the Dutch version of the FAAM was evaluated for its reliability and validity in 369 patients with a variety of foot and ankle complaints. The reliability was assessed by calculating the intraclass correlation coefficients (ICC, test-retest reliability), Cronbach's alpha (internal consistency), the standard error of measurement and the minimal detectable change (MDC). Additionally, this was done for athletes. The construct validity was assessed by the use of Spearman's correlation coefficient between FAAM domains and similar and contradictory domains of the Foot and Ankle Outcome Score, Short Form 36 and the Numeric Rating Scale for pain. The ICC of the subscales ranged from 0.62 to 0.86. Cronbach's alpha's minimum was 0.97. At individual level, the MDC ranged from 23.9 to 44.7 and at group level from 2.77 to 4.32. In the subgroup of athletes, the reliability was higher. The hypothesized correlations of the construct validity were supported by an 80% confirmation rate. The Dutch version of the FAAM met adequate measurement properties, although the reliability is not optimal. The FAAM-Sport subscale is more useful in athletes and the FAAM-Sport % seems not to contribute. In athletes with various foot and ankle symptoms, the FAAM can be used for functional assessment and follow-up at group level. For the general population, the FAAM is less appropriate. Diagnostic study, Level I.
Ardalan, Ali; Sohrabizadeh, Sanaz
2016-02-25
Iran is placed among countries suffering from the highest number of earthquake casualties. Household preparedness, as one component of risk reduction efforts, is often supported in quake-prone areas. In Iran, lack of a valid and reliable household preparedness tool was reported by previous disaster studies. This study is aimed to fill this gap by developing a valid and reliable tool for assessing household preparedness in the event of an earthquake. This survey was conducted through three phases including literature review and focus group discussions with the participation of eight key informants, validity measurements and reliability measurements. Field investigation was completed with the participation of 450 households within three provinces of Iran. Content validity, construct validity, the use of factor analysis; internal consistency using Cronbach's alpha coefficient, and test-retest reliability were carried out to develop the tool. Based on the CVIs, ranging from 0.80 to 0.100, and exploratory factor analysis with factor loading of more than 0.5, all items were valid. The amount of Cronbach's alpha (0.7) and test-retest examination by Spearman correlations indicated that the scale was also reliable. The final instrument consisted of six categories and 18 questions including actions at the time of earthquakes, nonstructural safety, structural safety, hazard map, communications, drill, and safety skills. Using a Persian-version tool that is adjusted to the socio-cultural determinants and native language may result in more trustful information on earthquake preparedness. It is suggested that disaster managers and researchers apply this tool in their future household preparedness projects. Further research is needed to make effective policies and plans for transforming preparedness knowledge into behavior.
Validation of a telephone screening tool for spasmodic dysphonia and vocal fold tremor.
Johnson, David M; Hapner, Edie R; Klein, Adam M; Pethan, Madeleine; Johns, Michael M
2014-11-01
The objective of this study was to ascertain whether clinicians can reliably distinguish between spasmodic dysphonia (SD)/vocal tremor and other voice disorders by telephone, despite this modality's limited frequency response. Randomized, single-blinded, and prospective study. Voice-disordered patients with (n = 22) and without (n = 17) SD and/or vocal tremor recorded standardized utterances via landline telephone. A laryngologist and two speech-language pathologists blinded to the diagnoses rated each recording as "yes" or "no" to "SD or tremor present?," and if "yes" categorized into adductor, abductor, tremor only, or adductor with tremor subtypes. Twenty-one recordings were presented twice at random so intrarater reliability could be assessed. All ratings were compared with gold standard diagnosis by a second laryngologist who performed a full examination, including videostroboscopy, on each patient. For the comparison "SD or tremor" yes versus no, sensitivity, specificity, positive predictive value, and negative predictive value are 90%, 95%, 96%, and 89%, respectively. Interrater reliability (Cohen kappa) compared with the gold standard ranged from 0.70 to 0.93 (substantial to almost perfect agreement). Cronbach alpha among three raters was 0.90 for this comparison. Intrarater reliability (number matched/number inspected) was very high, ranging from 0.97 to 1.0. Comparing gold standard and telephone rating of SD/tremor subtypes, kappa ranged from 0.48 to 0.60 (moderate agreement). Cronbach alpha among three raters was 0.88 for this comparison. Intrarater reliability ranged from 0.84 to 0.97. SD and tremor can be reliably distinguished from other voice disorders over the telephone. Copyright © 2014 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Tan, Christine L; Hassali, Mohamed A; Saleem, Fahad; Shafie, Asrul A; Aljadhey, Hisham; Gan, Vincent B
2015-01-01
(i) To develop the Pharmacy Value-Added Services Questionnaire (PVASQ) using emerging themes generated from interviews. (ii) To establish reliability and validity of questionnaire instrument. Using an extended Theory of Planned Behavior as the theoretical model, face-to-face interviews generated salient beliefs of pharmacy value-added services. The PVASQ was constructed initially in English incorporating important themes and later translated into the Malay language with forward and backward translation. Intention (INT) to adopt pharmacy value-added services is predicted by attitudes (ATT), subjective norms (SN), perceived behavioral control (PBC), knowledge and expectations. Using a 7-point Likert-type scale and a dichotomous scale, test-retest reliability (N=25) was assessed by administrating the questionnaire instrument twice at an interval of one week apart. Internal consistency was measured by Cronbach's alpha and construct validity between two administrations was assessed using the kappa statistic and the intraclass correlation coefficient (ICC). Confirmatory Factor Analysis, CFA (N=410) was conducted to assess construct validity of the PVASQ. The kappa coefficients indicate a moderate to almost perfect strength of agreement between test and retest. The ICC for all scales tested for intra-rater (test-retest) reliability was good. The overall Cronbach' s alpha (N=25) is 0.912 and 0.908 for the two time points. The result of CFA (N=410) showed most items loaded strongly and correctly into corresponding factors. Only one item was eliminated. This study is the first to develop and establish the reliability and validity of the Pharmacy Value-Added Services Questionnaire instrument using the Theory of Planned Behavior as the theoretical model. The translated Malay language version of PVASQ is reliable and valid to predict Malaysian patients' intention to adopt pharmacy value-added services to collect partial medicine supply.
Assurance of Learning, "Closing the Loop": Utilizing a Pre and Post Test for Principles of Finance
ERIC Educational Resources Information Center
Flanegin, Frank; Letterman, Denise; Racic, Stanko; Schimmel, Kurt
2010-01-01
Since there is no standard national Pre and Post Test for Principles of Finance, akin to the one for Economics, by authors created one by selecting questions from previously administered examinations. The Cronbach's Alpha of 0.851, exceeding the minimum of 0.70 for reliable pen and paper test, indicates that our Test can detect differences in…
An Evaluation of the Effectiveness of the New Primary School Mathematics Curriculum in Practice
ERIC Educational Resources Information Center
Gomleksiz, Mehmet Nuri; Bulut, Ilhami
2007-01-01
The aim of this study is to determine and compare the views of primary school teachers on the implementation and effectiveness of the new primary school mathematics curriculum. For that aim, a 32-item Likert-type Mathematics Curriculum Scale was developed. The reliability of the scale was tested through Cronbach Alpha (0.98), Spearman-Brown (0.93)…
[Validation of the German version of the Oxford Elbow Score : A cross-sectional study].
Marquardt, J; Schöttker-Königer, T; Schäfer, A
2016-08-01
Elbow complaints are complex problems leading to severe consequences for affected people and the healthcare system. The German version of the Oxford Elbow Score (OES) is the first German-speaking instrument that specifically measures elbow complaints from the patient's perspective and changes of their health status. The aim of this study is the validation of the German version of the OES. In this context the internal consistency and the construct validity were investigated. 59 patients with elbow complaints completed the German version of the OES, the DASH and the SF-36 in a cross-sectional study. The internal consistency was calculated with Cronbach's alpha coefficients. Spearman's correlation coefficients were used to confirm construct validity. Cronbach's alpha for pain, function and psychological subscales was 0.88, 0.81 and 0.90, respectively. The whole questionnaire presents a Cronbach's alpha value of 0.93. Convergent construct validity was confirmed with correlation coefficients containing values of -0.84, -0.77 and -0.82 compared to DASH and values ranging from 0.41 to 0.80 compared with the physical domains of the SF-36. The divergent construct validity presented values ranging from 0.07 to 0.20 with the SF-36 domains of "general health perception" and "mental health". The German OES is an internal consistent instrument with good convergent and divergent construct validity. Other aspects of the validity, the reliability and the responsiveness should be confirmed through further studies.
Khazaee-Pool, Maryam; Moridi, Minoo; Ponnet, Koen; Turner, Nigel; Pashaei, Tahereh
2016-11-01
Predicting time to relapse provides an opportunity for the development of relapse prevention interventions in drug users. The aim of the present study was to describe the development of the Persian version of the 9-item Time to Relapse Questionnaire (TRQ) and to evaluate its psychometric properties in an Iranian sample of treatment-seeking individuals with substance dependence (n = 150). The forward-backward method was used to translate the TRQ scale from English into Persian. After linguistic validation and a pilot check, a cross-sectional study was performed, and psychometric properties of the Iranian version of the questionnaire were assessed. The reliability was evaluated by Cronbach's alpha and test-retest analyses. In addition, the factor structure of the scale was extracted by applying confirmatory factor analysis. The mean age of participants was 40.52 (SD = 11.30) years. The mean scores for the content validity index (CVI) and the content validity ratio (CVR) were 0.93 and 0.81, respectively. A confirmatory factor analysis (CFA) demonstrated that the three-factor model of the TRQ was a good fit for the data and thus replicated the factor structure of the original English language TRQ. Cronbach's alpha presented good internal consistency (alpha = 0.76), and test-retest reliability of the TRQ instrument with 2-week intervals was appropriate (ICC = 0.84). The findings demonstrate that the Persian version of the TRQ is a reliable and valid scale for measuring time to relapse in Iranian drug users. The TRQ can be applied at the start of treatment so that clinical interventions can be targeted toward the different relapse styles.
Martínez-Gómez, David; Martínez-de-Haro, Vicente; Pozo, Tamara; Welk, Gregory J; Villagra, Ariel; Calle, Marisa E; Marcos, Ascensión; Veiga, Oscar L
2009-01-01
Questionnaires are feasible instruments to assess physical activity (PA) in large samples. The aim of the current study was to evaluate the reliability and validity of the PAQ-A questionnaire in Spanish adolescents using the measurement of PA by accelerometer as criterion. In a sample of 82 adolescents, aged 12 to 17 years, 1-week PAQ-A test-retest was administered. Reliability was analyzed by the Intraclass Correlation Coefficient (ICC) and the internal consistency by the Cronbach's alpha Coefficient. Two hundred thirty-two adolescents, aged 13-17 years, completed the PAQ-A and wore the ActiGraph GT1M accelerometer during 7-days. The PAQ-A was compared against total PA and moderate to vigorous PA (MVPA) obtained by the accelerometer. Test-retest reliability showed ICC = 0.71 for the final score of PAQ-A. Internal consistency was alpha = 0.65 in the first self-report, alpha = 0.67 in the retest in 82 adolescents sample, and alpha = 0.74 in the 232 adolescents sample. The PAQ-A was moderately correlated with total PA (rho = 0.39) and MVPA (rho= 0.34) assessed by the accelerometer. The PAQ-A obtained significantly moderate correlations in boys but not in girls against the accelerometer. The PAQ-A questionnaire shows an adequate reliability and a reasonable validity for assessing PA in Spanish adolescents.
Translating and validating a Training Needs Assessment tool into Greek
Markaki, Adelais; Antonakis, Nikos; Hicks, Carolyn M; Lionis, Christos
2007-01-01
Background The translation and cultural adaptation of widely accepted, psychometrically tested tools is regarded as an essential component of effective human resource management in the primary care arena. The Training Needs Assessment (TNA) is a widely used, valid instrument, designed to measure professional development needs of health care professionals, especially in primary health care. This study aims to describe the translation, adaptation and validation of the TNA questionnaire into Greek language and discuss possibilities of its use in primary care settings. Methods A modified version of the English self-administered questionnaire consisting of 30 items was used. Internationally recommended methodology, mandating forward translation, backward translation, reconciliation and pretesting steps, was followed. Tool validation included assessing item internal consistency, using the alpha coefficient of Cronbach. Reproducibility (test – retest reliability) was measured by the kappa correlation coefficient. Criterion validity was calculated for selected parts of the questionnaire by correlating respondents' research experience with relevant research item scores. An exploratory factor analysis highlighted how the items group together, using a Varimax (oblique) rotation and subsequent Cronbach's alpha assessment. Results The psychometric properties of the Greek version of the TNA questionnaire for nursing staff employed in primary care were good. Internal consistency of the instrument was very good, Cronbach's alpha was found to be 0.985 (p < 0.001) and Kappa coefficient for reproducibility was found to be 0.928 (p < 0.0001). Significant positive correlations were found between respondents' current performance levels on each of the research items and amount of research involvement, indicating good criterion validity in the areas tested. Factor analysis revealed seven factors with eigenvalues of > 1.0, KMO (Kaiser-Meyer-Olkin) measure of sampling adequacy = 0.680 and Bartlett's test of sphericity, p < 0.001. Conclusion The translated and adapted Greek version is comparable with the original English instrument in terms of validity and reliability and it is suitable to assess professional development needs of nursing staff in Greek primary care settings. PMID:17474989
Parvizi, Mohammad Mahdi; Amini, Mitra; Dehghani, Mohammad Reza; Jafari, Peyman; Parvizi, Zahra
2016-01-01
Evaluation is the main component in design and implementation of educational activities and rapid growth of educational institution programs. Outpatient medical education and clinical training environment is one of the most important parts of training of medical residents. This study aimed to determine the validity and reliability of the Persian version of Ambulatory Care Learning Educational Environment Measure (ACLEEM) questionnaire, as an instrument for assessment of educational environments in residency medical clinics. This study was performed on 180 residents in Shiraz University of Medical Sciences, Shiraz, Iran, in 2014-2015. The questionnaire designers' electronic permission (by email) and the residents' verbal consent were obtained before distributing the questionnaires. The study data were gathered using ACLEEM questionnaire developed by Arnoldo Riquelme in 2013. The data were analyzed using the SPSS statistical software, version 14, and MedCalc ® software. Then, the construct validity, including convergent and discriminant validities, of the Persian version of ACLEEM questionnaire was assessed. Its internal consistency was also checked by Cronbach's alpha coefficient. Five team members who were experts in medical education were consulted to test the cultural adaptation, linguistic equivalency, and content validity of the Persian version of the questionnaire. Content validity indexes were >0.9 in all items. In factor analysis of the instrument, the Kaiser-Meyer-Olkin index was 0.928 and Barlett's sphericity test yielded the following results: X 2 =6,717.551, df =1,225, and P ≤0.001. Besides, Cronbach's alpha coefficient of ACLEEM questionnaire was 0.964. Cronbach's alpha coefficients were also >0.80 in all the three domains of the questionnaire. Overall, the Persian version of ACLEEM showed excellent convergent validity and acceptable discriminant validity, except for the clinical training domain. According to the results, the Persian version of ACLEEM questionnaire was a valid and reliable instrument for Iranian residents to assess specialized clinics and residency ambulatory settings.
Kamradt, Martina; Bozorgmehr, Kayvan; Krisam, Johannes; Freund, Tobias; Kiel, Marion; Qreini, Markus; Flum, Elisabeth; Berger, Sarah; Besier, Werner; Szecsenyi, Joachim; Ose, Dominik
2014-12-18
One of the most widely used self-reporting tools assessing diabetes self-management in English is the Summary of Diabetes Self-Care Activities (SDSCA) measure. To date there is no psychometric validated instrument in German to assess self-management in patients with diabetes mellitus. Therefore, this study aimed to translate the SDSCA into German and examine its psychometric properties. The English version of the SDSCA was translated into German following the guidelines for cultural adaptation. The German version of the SDSCA (SDSCA-G) was administered to a random sample of 315 patients with diabetes mellitus type 2. Reliability was analyzed using Cronbach's alpha coefficient and item characteristics were assessed. Exploratory and confirmatory factor analysis (EFA and CFA) were carried out to explore the construct validity. A multivariable linear regression model was used to identify the influence of predictor variables on the SDSCA-G sum score. The Cronbach's alpha for the SDSCA-G (all items) was α = 0.618 and an acceptable correlation between the SDSCA-G and Self-management Diabetes Mellitus-Questionnaire (SDQ) (ρ = 0.664) was identified. The EFA suggested a four factor construct as did the postulated model. The CFA showed the goodness of fit of the SDSCA-G. However, item 4 was found to be problematic regarding the analysis of psychometric properties. The omission of item 4 yielded an increase in Cronbach's alpha (α = 0.631) and improvements of the factor structure and model fit. No statistically significant influences of predictor variables on the SDSCA-G sum score were observed. The revised German version of the SDSCA (SDSCA-G) is a reliable and valid tool assessing self-management in adults with type 2 diabetes in Germany.
Factor structure of the functional movement screen in marine officer candidates.
Kazman, Josh B; Galecki, Jeffrey M; Lisman, Peter; Deuster, Patricia A; OʼConnor, Francis G
2014-03-01
Functional movement screening (FMS) is a musculoskeletal assessment that is intended to fill a gap between preparticipation examinations and performance tests. Functional movement screening consists of 7 standardized movements involving multiple muscle groups that are rated 0-3 during performance; scores are combined into a final score, which is intended to predict injury risk. This use of a sum-score in this manner assumes that the items are unidimensional and scores are internally consistent, which are measures of internal reliability. Despite research into the FMS' predictive value and interrater reliability, research has not assessed its psychometric properties. The present study is a standard psychometric analysis of the FMS and is the first to assess the internal consistency and factor structure of the FMS, using Cronbach's alpha and exploratory factor analysis (EFA). Using a cohort of 877 male and 57 female Marine officer candidates who performed the FMS, EFA of polychoric correlations with varimax rotation was conducted to explore the structure of the FMS. Tests were repeated on the original scores, which integrated feelings of pain during movement (0-3), and then on scores discounting the pain instruction and based only on the performance (1-3), to determine whether pain ratings affected the factor structure. The average FMS score was 16.7 ± 1.8. Cronbach's alpha was 0.39. Exploratory factor analysis availed 2 components accounting for 21 and 17% and consisting of separate individual movements (shoulder mobility and deep squat, respectively). Analysis on scores discounting pain showed similar results. The factor structures were not interpretable, and the low Cronbach's alpha suggests a lack of internal consistency in FMS sum scores. Results do not offer support for validity of the FMS sum score as a unidimensional construct. In the absence of additional psychometric research, caution is warranted when using the FMS sum score.
Georgieva-Zhostova, Spaska; Kolev, Ognyan I; Stambolieva, Katerina
2014-09-01
The aim of the present study was the translation, cross-cultural adaptation and validation of the Dizziness Handicap Inventory in Bulgarian language (DHI-BG). Ninety-seven vestibular patients (19 men and 78 women, mean age 45.08 ± 13.85 years) took part in the investigation. All participants were asked to fill in the DHI-BG. Internal consistency was estimated using Cronbach's alpha and item-total correlation, reproducibility by calculating Bland-Altman's limits of agreement and intraclass correlation coefficients (ICCs). Associations were estimated by Spearman's correlation coefficients. The Cronbach's alpha for the total score, functional, physical and emotional subscales of DHI-BG were 0.88, 0.75, 0.72 and 0.81. The floor and ceiling effects of the DHI-BG total scale were evaluated with respect to the limits of agreement which were ±9.4-14.53 points. Intraclass correlation coefficients (ICCs) for all scale and subscales were higher than the recommended value of 0.75 and determined good test-retest reliability. The range of items correlation for DHI-BG was from 0.27 (item 12) to 0.72 (item 3). No significant differences were observed in the Cronbach's alpha coefficients between the DHI-BG and the original version, the German and Italian versions of the questionnaire. The most significant difference was observed in comparison with the German version of DHI. Construct validity presented a moderate correlation between Romberg coefficients and DHI-BG scores and strong correlation between all scores of DHI and the self-perceived disability. The results suggest that DHI-BG scores show a good discriminative validity between groups with different levels of self-assessed disability. The Bulgarian version of the DHI is a reliable and valid tool in assessing the impact of dizziness on the quality of life in Bulgarian vestibular patients.
Alpern, Rachelle; Canavan, Maureen E; Thompson, Jennifer T; McNatt, Zahirah; Tatek, Dawit; Lindfield, Tessa; Bradley, Elizabeth H
2013-01-01
Ethiopia is one of 57 countries identified by the World Health Report 2006 as having a severely limited number of health care professionals. In recognition of this shortage, the Ethiopian Federal Ministry of Health, through the Ethiopian Hospital Management Initiative, prioritized the need to improve retention of health care workers. Accordingly, we sought to develop the Satisfaction of Employees in Health Care (SEHC) survey for use in hospitals and health centers throughout Ethiopia. Literature reviews and cognitive interviews were used to generate a staff satisfaction survey for use in the Ethiopian healthcare setting. We pretested the survey in each of the six hospitals and four health centers across Ethiopia (98% response rate). We assessed content validity and convergent validity using factor analysis and examined reliability using the Cronbach alpha coefficients to assess internal consistency. The final survey was comprised of 18 questions about specific aspects of an individual's work and two overall staff satisfaction questions. We found support for content validity, as data from the 18 responses factored into three factors, which we characterized as 1) relationship with management and supervisors, 2) job content, and 3) relationships with coworkers. Summary scores for two factors (relationship with management and supervisors and job content) were significantly associated (P-value, <0.001) with the two overall satisfaction items. Cronbach's alpha coefficients showed good to excellent internal consistency (Cronbach alpha coefficients >0.70) for the items in the three summary scores. The introduction of consistent and reliable measures of staff satisfaction is crucial to understand and improve employee retention rates, which threaten the successful achievement of the Millennium Development Goals in low-income countries. The use of the SEHC survey in Ethiopian healthcare facilities has ample leadership support, which is essential for addressing problems that reduce staff satisfaction and exacerbate excessive workforce shortages.
Mi, Misa; Moseley, James L; Green, Michael L
2012-02-01
Many residency programs offer training in evidence-based medicine (EBM). However, these curricula often fail to achieve optimal learning outcomes, perhaps because they neglect various contextual factors in the learning environment. We developed and validated an instrument to characterize the environment for EBM learning and practice in residency programs. An EBM Environment Scale was developed following scale development principles. A survey was administered to residents across six programs in primary care specialties at four medical centers. Internal consistency reliability was analyzed with Cronbach's coefficient alpha. Validity was assessed by comparing predetermined subscales with the survey's internal structure as assessed via factor analysis. Scores were also compared for subgroups based on residency program affiliation and residency characteristics. Out of 262 eligible residents, 124 completed the survey (response rate 47%). The overall mean score was 3.89 (standard deviation=0.56). The initial reliability analysis of the 48-item scale had a high reliability coefficient (Cronbach α=.94). Factor analysis and further item analysis resulted in a shorter 36-item scale with a satisfactory reliability coefficient (Cronbach α=.86). Scores were higher for residents with prior EBM training in medical school (4.14 versus 3.62) and in residency (4.25 versus 3.69). If further testing confirms its properties, the EBM Environment Scale may be used to understand the influence of the learning environment on the effectiveness of EBM training. Additionally, it may detect changes in the EBM learning environment in response to programmatic or institutional interventions.
Murrock, Carolyn J; Gary, Faye
2014-01-01
This secondary analysis tested the reliability and validity of the Self-Efficacy for Exercise (SEE) and the Outcome Expectations for Exercise (OEE) scales in 126 community dwelling, middle aged African American women. Social Cognitive Theory postulates self-efficacy is behavior age, gender and culture specific. Therefore, it is important to determine ifself-efficacy scales developed and tested in older Caucasian female adults are reliable and valid in middle aged, minority women. Cronbach's alpha and construct validity using hypothesis testing and confirmatory factor analysis supported the reliability and validity of the SEE and OEE scales in community dwelling, middle aged African American women.
Muehrer, Rebecca J; Lanuza, Dorothy M; Brown, Roger L; Djamali, Arjang
2015-01-01
This study describes the development and psychometric testing of the Sexual Concerns Questionnaire (SCQ) in kidney transplant (KTx) recipients. Construct validity was assessed using the Kroonenberg and Lewis exploratory/confirmatory procedure and testing hypothesized relationships with established questionnaires. Configural and weak invariance were examined across gender, dialysis history, relationship status, and transplant type. Reliability was assessed with Cronbach's alpha, composite reliability, and test-retest reliability. Factor analysis resulted in a 7-factor solution and suggests good model fit. Construct validity was also supported by the tests of hypothesized relationships. Configural and weak invariance were supported for all subgroups. Reliability of the SCQ was also supported. Findings indicate the SCQ is a valid and reliable measure of KTx recipients' sexual concerns.
Rauseo Vera, Mayra; Gutiérrez-González, Luis Arturo; Maldonado, Irama; Al Snih, Soham
2017-09-21
Spondyloarthropathies (SpA) are disabling diseases with a prevalence of 1.9% in the general population. The indices designed for monitoring the disease should be valid, reliable and cross-culturally adapted for decision-making concerning the appropriate treatment. Changing an adjective or pronoun in a self-administered questionnaire could be the big difference in condensing an idea in a few words and transmitting that concept to all those who share the same language. To develop a Venezuelan version of the original English version of the BASDAI/BASFI and to evaluate its reliability and validity in Venezuelan patients with SpA. Certified linguists were needed for the translation of a Venezuelan version of the BASDAI/BASFI. The evaluation of reliability and validity was performed by calculating correlation coefficients in addition to Cronbach's alpha correlation between the BASDAI score and the clinical parameters (for example: erythrocyte sedimentation rate, C-reactive protein, modified Schöber test, occiput-to-wall distance and enthesis count). We studied 40 patients including 31 men (77.5%) and 9 women (22.5%). The mean age was 35.9 years ± standard deviation (SD) 12.01 and the disease duration was 11.5 years (± SD 9.5). The most common diagnoses were undifferentiated spondyloarthritis (45%), ankylosing spondylitis (27.5%) and psoriatic arthritis (20%). The incidences of reactive arthritis, ankylosing spondylitis and juvenile Reiter's syndrome were 2.5% each. The test-retest reliability of the BASDAI and BASFI was high (R = 0.99 and 0.99, respectively; P<.0001). The internal consistency for the BASDAI was high (Cronbach's alpha = 0.88; P=.002) and the intraclass correlation coefficient for internal consistency: 0.9867 (P=.001). Internal consistency for the BASFI: Cronbach's alpha = 0.7985 (P=.002), intraclass correlation coefficient for internal consistency: 0.9055 (P=.001). Construct validity of the BASDAI was high for general well-being of the patient (R = 0.84) and for enthesis count (R = 0.84). Low back pain showed moderate correlation with BASDAI (R = 0.69; P<.0001) and the erythrocyte sedimentation rate showed a low correlation (R = 0.39683; P=.0112). The Venezuelan version of the BASDAI/BASFI could be used in clinical research to assess and evaluate the course of disease activity in Venezuelan SpA patients. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.
Reliability beyond Theory and into Practice
ERIC Educational Resources Information Center
Sijtsma, Klaas
2009-01-01
The critical reactions of Bentler (2009, doi: 10.1007/s11336-008-9100-1), Green and Yang (2009a, doi: 10.1007/s11336-008-9098-4 ; 2009b, doi: 10.1007/s11336-008-9099-3), and Revelle and Zinbarg (2009, doi: 10.1007/s11336-008-9102-z) to Sijtsma's (2009, doi: 10.1007/s11336-008-9101-0) paper on Cronbach's alpha are addressed. The dissemination of…
ERIC Educational Resources Information Center
Kesan, Cenk; Ozkalkan, Zuhal; Iric, Hamdullah; Kaya, Deniz
2012-01-01
In the exams based on limits and derivatives, in this study, it was tried to determine that if there was any difference in students' test scores according to the type of music listened to and environment without music. For this purpose, the achievement test including limits and derivatives and whose reliability coefficient of Cronbach Alpha is…
Melchiorre, Maria Gabriella; Di Rosa, Mirko; Barbabella, Francesco; Barbini, Norma; Lattanzio, Fabrizia; Chiatti, Carlos
2017-01-01
Introduction . Elder abuse is often a hidden phenomenon and, in many cases, screening practices are difficult to implement among older people with dementia. The Caregiver Abuse Screen (CASE) is a useful tool which is administered to family caregivers for detecting their potential abusive behavior. Objectives . To validate the Italian version of the CASE tool in the context of family caregiving of older people with Alzheimer's disease (AD) and to identify risk factors for elder abuse in Italy. Methods . The CASE test was administered to 438 caregivers, recruited in the Up-Tech study. Validity and reliability were evaluated using Spearman's correlation coefficients, principal-component analysis, and Cronbach's alphas. The association between the CASE and other variables potentially associated with elder abuse was also analyzed. Results . The factor analysis suggested the presence of a single factor, with a strong internal consistency (Cronbach's alpha = 0.86). CASE score was strongly correlated with well-known risk factors of abuse. At multivariate level, main factors associated with CASE total score were caregiver burden and AD-related behavioral disturbances. Conclusions . The Italian version of the CASE is a reliable and consistent screening tool for tackling the risk of being or becoming perpetrators of abuse by family caregivers of people with AD.
Vrotsou, Kalliopi; Cuéllar, Ricardo; Silió, Félix; Rodriguez, Miguel Ángel; Garay, Daniel; Busto, Gorka; Trancho, Ziortza; Escobar, Antonio
2016-10-18
The aim of the current study was to validate the self-report section of the American Shoulder and Elbow Surgeons questionnaire (ASES-p) into Spanish. Shoulder pathology patients were recruited and followed up to 6 months post treatment. The ASES-p, Constant, SF-36 and Barthel scales were filled-in pre and post treatment. Reliability was tested with Cronbach's alpha, convergent validity with Spearman's correlations coefficients. Confirmatory factor analysis (CFA) and the Rasch model were implemented for assessing structural validity and unidimensionality of the scale. Models with and without the pain item were considered. Responsiveness to change was explored via standardised effect sizes. Results were acceptable for both tested models. Cronbach's alpha was 0.91, total scale correlations with Constant and physical SF-36 dimensions were >0.50. Factor loadings for CFA were >0.40. The Rasch model confirmed unidimensionality of the scale, even though item 10 "do usual sport" was suggested as non-informative. Finally, patients with improved post treatment shoulder function and those receiving surgery had higher standardised effect sizes. The adapted Spanish ASES-p version is a valid and reliable tool for shoulder evaluation and its unidimensionality is supported by the data.
Perceived Stress Scale: reliability and validity study in Greece.
Andreou, Eleni; Alexopoulos, Evangelos C; Lionis, Christos; Varvogli, Liza; Gnardellis, Charalambos; Chrousos, George P; Darviri, Christina
2011-08-01
To translate the Perceived Stress Scale (versions PSS-4, -10 and -14) and to assess its psychometric properties in a sample of general Greek population. 941 individuals completed anonymously questionnaires comprising of PSS, the Depression Anxiety and Stress scale (DASS-21 version), and a list of stress-related symptoms. Psychometric properties of PSS were investigated by confirmatory factor analysis (construct validity), Cronbach's alpha (reliability), and by investigating relations with the DASS-21 scores and the number of symptoms, across individuals' characteristics. The two-factor structure of PSS-10 and PSS-14 was confirmed in our analysis. We found satisfactory Cronbach's alpha values (0.82 for the full scale) for PSS-14 and PSS-10 and marginal satisfactory values for PSS-4 (0.69). PSS score exhibited high correlation coefficients with DASS-21 subscales scores, meaning stress (r = 0.64), depression (r = 0.61), and anxiety (r = 0.54). Women reported significantly more stress compared to men and divorced or widows compared to married or singled only. A strong significant (p < 0.001) positive correlation between the stress score and the number of self-reported symptoms was also noted. The Greek versions of the PSS-14 and PSS-10 exhibited satisfactory psychometric properties and their use for research and health care practice is warranted.
Validation of a pregnancy planning measure for Arabic-speaking women.
Almaghaslah, Eman; Rochat, Roger; Farhat, Ghada
2017-01-01
The prevalence of unplanned pregnancy in Saudi Arabia has not been thoroughly investigated. To conduct a psychometric evaluation study of the Arabic version of the London Measure of Unplanned Pregnancy (LMUP). To evaluate the psychometric properties of the LMUP, we conducted a self-administered online survey among 796 ever-married Saudi women aged 20-49 years, and a re-test survey among 24 women. The psychometric properties evaluated included content validity measured by content validity index (CVI), structural validity assessed by exploratory factor analysis (EFA), substantive validity assessed by hypothesis testing, contextual stability for the test-retest assessed by weighted Kappa, and internal consistency assessed by Cronbach's alpha. The psychometric analysis of the Arabic version of LMUP exhibited valid and reliable properties. The CVIs for individual items and at the scale level were >0.7. EFA confirmed a unidimensional extraction of the scale item. Hypothesis testing confirmed expected associations. The tool was stable with weighted kappa = 0.78 and Cronbach's alpha = 0.88. In this study, the validity and reliability of the Arabic version of the LMUP were confirmed according to well-known psychometric criteria. This LMUP version can be used in research studies among Arabic-speaking women to measure unplanned pregnancy and investigate correlates and outcomes related to unplanned pregnancy.
Vietnamese validation of the short version of Internet Addiction Test.
Tran, Bach Xuan; Mai, Hue Thi; Nguyen, Long Hoang; Nguyen, Cuong Tat; Latkin, Carl A; Zhang, Melvyn W B; Ho, Roger C M
2017-12-01
The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT) and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analysis was used to identify the associated factors. The two-factor model of Vietnamese version of s-IAT demonstrated good psychometric properties. The internal consistency of Factor 1 (loss of control/time management) was high (Cronbach's alpha = 0.82) and Factor 2 (craving/social problems) was satisfactory (Cronbach's alpha = 0.75). Findings indicated that 20.9% youths were addicted to the Internet. Regression analysis revealed significant associations between Internet addiction and having problems in self-care, lower quality of life and high perceived stress scores. The Vietnamese version of s-IAT is a valid and reliable instrument to assess IA in Vietnamese population. Due to the high prevalence of IA among Vietnamese youths, IA should be paid attention in future intervention programs. s-IAT can be a useful screening tool for IA to promptly inform and treat the IA among Vietnamese youths.
Yildirim, Aysegul; Akinci, Fevzi; Gozu, Hulya; Sargin, Haluk; Orbay, Ekrem; Sargin, Mehmet
2007-06-01
The aim of this study was to test the validity and reliability of the Turkish version of the diabetes quality of life (DQOL) questionnaire for use with patients with diabetes. Turkish version of the generic quality of life (QoL) scale 15D and DQOL, socio-demographics and clinical parameter characteristics were administered to 150 patients with type 2 diabetes. Study participants were randomly sampled from the Endocrinology and Diabetes Outpatient Department of Dr. Lutfi Kirdar Kartal Education and Research Hospital in Istanbul, Turkey. The Cronbach alpha coefficient of the overall DQOL scale was 0.89; the Cronbach alpha coefficient ranged from 0.80 to 0.94 for subscales. Distress, discomfort and its symptoms, depression, mobility, usual activities, and vitality on the 15 D scale had statistically significant correlations with social/vocational worry and diabetes-related worry on the DQOL scale indicating good convergent validity. Factor analysis identified four subscales: satisfaction", impact", "diabetes-related worry", and "social/vocational worry". Statistical analyses showed that the Turkish version of the DQOL is a valid and reliable instrument to measure disease related QoL in patients with diabetes. It is a simple and quick screening tool with about 15 +/- 5.8 min administration time for measuring QoL in this population.
[Validation of a dietary habits questionnaire related to fats and sugars intake].
Aráuz Hernández, Ana Gladys; Roselló Araya, Marlene; Guzmán Padilla, Sonia; Padilla Vargas, Gioconda
2008-12-01
The objective of this study was to design and validate a psychometric tool to measure dietary practices related to the intake of fats and sugars in a sample of overweight and obese adults. Classical test theory was applied. The validated construct was dietary habits, and the following theoretical dimensions were utilized: exclusion, modification, substitution and replacement. These had been previously defined in similar studies conducted in other countries. The tool was validated with 139 adults, males and females, with body mass indexes equal to or higher than 25. Construct validity for each section of the tool was obtained through factor analysis. The final tool was made up of 47 items. Cronbach's Alpha reliability coefficient was 0.948, which indicates a highly satisfactory internal consistency. Using sediment graph data and factor analysis of the four proposed theoretical dimensions of behavior, items were fused into two dimensions with a cumulative variance of 58%. These were renamed "elimination" and "modification". Cronbach's Alphas were 0.906 and 0.873, respectively, indicating a high level of reliability for construct measurement. Results show the need to adapt foreign tools to our socio-cultural context before utilizing them in interventions intended to modify dietary patterns, since these are interrelated to other aspects of the culture itself.
Gagnon, Susie; Labrecque, Michel; Njoya, Merlin; Rousseau, François; St-Jacques, Sylvie; Légaré, France
2010-02-01
To assess the extent to which family physicians (FPs) involve women in decisions about prenatal screening for Down syndrome. Based on transcripts of consultations between 41 FPs and 128 women, two raters independently assessed clinician's efforts to involve women in decisions about prenatal screening for Down syndrome using the French-language version of OPTION. Descriptive statistics of OPTION scores were calculated. Construct validity was assessed by performing a principal factor analysis and by measuring association with consultation duration and FPs sociodemograhics. Internal consistency was assessed with Cronbach's alpha and inter-rater reliability with the intraclass correlation coefficient. The overall mean OPTION score was low: 19 +/- 7 (range = 0 [no involvement] to 100 [high involvement]). One factor accounted for 80% of the variance. Both internal consistency and inter-rater reliability were very good (Cronbach's alpha = 0.73; ICC = 0.76). OPTION scores were lower for residents than for licensed FPs (17 +/- 5 vs 21 +/- 4; p = 0.02) and were positively associated with duration of consultation (r = 0.56; p < 0.001). Based on the French-language version of OPTION, which showed satisfactory psychometric properties, FPs studied put minimal efforts to involve women in decisions about prenatal screening for Down syndrome. (c) 2009 John Wiley & Sons, Ltd.
Navarro-Albarracín, César; Poiraudeau, Serge; Chico-Matallana, Noelia; Vergara-Martín, Jesús; Martin, William; Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A
2018-06-08
To validate the Spanish version of the Exercise Therapy Burden Questionnaire (ETBQ) for the assessment of barriers associated to doing physical therapy for the treatment of chronic ailments. A sample of 177 patients, 55.93% men and 44.07% women, with an average age of 51.03±14.91 was recruited. The reliability of the questionnaire was tested with Cronbach's alpha coefficient, and the validity of the instrument was assessed through the divergent validation process and factor analysis. The factor analysis was different to the original questionnaire, composed of a dimension, in this case determined three dimensions: (1) General limitations for doing physical exercise. (2) Physical limitations for doing physical exercise. (3) Limitations caused by the patients' predisposition to their exercises. The reliability of the test-retest was measured through the intraclass correlation coefficient (ICC) and the Bland-Altman plot. Cronbach's alpha was 0.8715 for the total ETBQ. The ICC of the test-retest was 0.745 and the Bland-Altman plot showed no systematic trend. We have obtained the translated version in Spanish of the ETBQ questionnaire. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.
Di Rosa, Mirko; Barbabella, Francesco; Barbini, Norma; Chiatti, Carlos
2017-01-01
Introduction. Elder abuse is often a hidden phenomenon and, in many cases, screening practices are difficult to implement among older people with dementia. The Caregiver Abuse Screen (CASE) is a useful tool which is administered to family caregivers for detecting their potential abusive behavior. Objectives. To validate the Italian version of the CASE tool in the context of family caregiving of older people with Alzheimer's disease (AD) and to identify risk factors for elder abuse in Italy. Methods. The CASE test was administered to 438 caregivers, recruited in the Up-Tech study. Validity and reliability were evaluated using Spearman's correlation coefficients, principal-component analysis, and Cronbach's alphas. The association between the CASE and other variables potentially associated with elder abuse was also analyzed. Results. The factor analysis suggested the presence of a single factor, with a strong internal consistency (Cronbach's alpha = 0.86). CASE score was strongly correlated with well-known risk factors of abuse. At multivariate level, main factors associated with CASE total score were caregiver burden and AD-related behavioral disturbances. Conclusions. The Italian version of the CASE is a reliable and consistent screening tool for tackling the risk of being or becoming perpetrators of abuse by family caregivers of people with AD. PMID:28265571
Pahel, Bhavna Talekar; Rozier, R Gary; Slade, Gary D
2007-01-01
Background Dental disease and treatment experience can negatively affect the oral health related quality of life (OHRQL) of preschool aged children and their caregivers. Currently no valid and reliable instrument is available to measure these negative influences in very young children. The objective of this research was to develop the Early Childhood Oral Health Impact Scale (ECOHIS) to measure the OHRQL of preschool children and their families. Methods Twenty-two health professionals evaluated a pool of 45 items that assess the impact of oral health problems on 6-14-year-old children and their families. The health professionals identified 36 items as relevant to preschool children. Thirty parents rated the importance of these 36 items to preschool children; 13 (9 child and 4 family) items were considered important. The 13-item ECOHIS was administered to 295 parents of 5-year-old children to assess construct validity and internal consistency reliability (using Cronbach's alpha). Test-retest reliability was evaluated among another sample of parents (N = 46) using the intraclass correlation coefficient (ICC). Results ECOHIS scores on the child and parent sections indicating worse quality of life were significantly associated with fair or poor parental ratings of their child's general and oral health, and the presence of dental disease in the child. Cronbach's alphas for the child and family sections were 0.91 and 0.95 respectively, and the ICC for test-retest reliability was 0.84. Conclusion The ECOHIS performed well in assessing OHRQL among children and their families. Studies in other populations are needed to further establish the instrument's technical properties. PMID:17263880
Kim, Shin-Jeong; Kim, Sunghee; Kang, Kyung-Ah; Oh, Jina; Lee, Myung-Nam
2016-02-01
The lack of reliable and valid tools to evaluate learning outcomes during simulations has limited the adoption and progress of simulation-based nursing education. This study had two aims: (a) to develop a simulation evaluation tool (SET(c-dehydration)) to assess students' clinical judgment in caring for children with dehydration based on the Lasater Clinical Judgment Rubric (LCJR) and (b) to examine its reliability and validity. Undergraduate nursing students from two nursing schools in South Korea participated in this study from March 3 through June 10, 2014. The SET(c-dehydration) was developed, and 120 nursing students' clinical judgment was evaluated. Descriptive statistics, Cronbach's alpha, Cohen's kappa coefficient, and confirmatory factor analysis (CFA) were used to analyze the data. A 41-item version of the SET(c-dehydration) with three subscales was developed. Cohen's kappa (measuring inter-observer reliability) of the sessions ranged from .73 to .95, and Cronbach's alpha was .87. The mean total rating of the SET(c-dehydration) by the instructors was 1.92 (±.25), and the mean scores for the four LCJR dimensions of clinical judgment were as follows: noticing (1.74±.27), interpreting (1.85±.43), responding (2.17±.32), and reflecting (1.79±.35). CFA, which was performed to test construct validity, showed that the four dimensions of the SET(c-dehydration) was an appropriate framework. The SET(c-dehydration) provides a means to evaluate clinical judgment in simulation education. Its reliability and validity should be examined further. Copyright © 2015 Elsevier Ltd. All rights reserved.
Validity and reliability of the Brazilian version of the Work Ability Index questionnaire.
Martinez, Maria Carmen; Latorre, Maria do Rosário Dias de Oliveira; Fischer, Frida Marina
2009-06-01
To evaluate the validity and reliability of the Portuguese language version of a work ability index. Cross sectional survey of a sample of 475 workers from an electrical company in the state of Sao Paulo, Southeastern Brazil (spread across ten municipalities in the Campinas area), carried out in 2005. The following aspects of the Brazilian version of the Work Ability Index were evaluated: construct validity, using factorial exploratory analysis, and discriminant capacity, by comparing mean Work Ability Index scores in two groups with different absenteeism levels; criterion validity, by determining the correlation between self-reported health and Work Ability Index score; and reliability, using Cronbach's alpha to determine the internal consistency of the questionnaire. Factorial analysis indicated three factors in the work ability construct: issues pertaining to 'mental resources' (20.6% of the variance), self-perceived work ability (18.9% of the variance), and presence of diseases and health-related limitations (18.4% of the variance). The index was capable of discriminating workers according to levels of absenteeism, identifying a significantly lower (p<0.0001) mean score among subjects with high absenteeism (37.2 points) when compared to those with low absenteeism (42.3 points). Criterion validity analysis showed a correlation between the index and all dimensions of health status analyzed (p<0.0001). Reliability of the index was high, with a Cronbach's alpha of 0.72. The Brazilian version of the Work Ability Index showed satisfactory psychometric properties with respect to construct validity, thus constituting an appropriate option for evaluating work ability in both individual and population-based settings.
Farazdaghi, Mohammad Reza; Mansoori, Ali; Vosoughi, Omid; Kordi Yoosefinejad, Amin
2017-05-01
Elbow joint pathologies are highly prevalent in Persian-speaking countries. A reliable low-cost method like an appropriate questionnaire is mandatory for the early diagnosis of elbow joint disorders. Among designed questionnaires, Patient-Rated Elbow Evaluation (PREE) is an accepted commonly used scale evaluating pain and dysfunction of the patients. The aims of the study were to cross-culturally adapt and also to identify the psychometric properties of the Persian PREE. The original version of the PREE was translated and cross-culturally adapted to Persian according to the guidelines by Beaton et al. Seventy-three patients and thirty-nine healthy people were enrolled in the study. Test-retest reliability and internal consistency were evaluated using ICC, Cronbach's alpha, and item-total correlation, respectively. Construct validity was investigated using Disability of Arm, Shoulder, and Hand (DASH) questionnaire and physical component scale of SF-36 (PCS). To determine a cutoff point for discriminating patients from non-patients, receiver operating characteristic curve was plotted. The Persian PREE displayed high internal consistency (Cronbach's alpha = 0.91) and had acceptable ICC values in the subscales and total score (ICC > 0.90). A positive moderate correlation with DASH (r = 0.66, P < 0.001) and a negative moderate correlation with PCS of SF-36 (r = -0.44, P < 0.001) were observed. The cutoff point equal to 13.16 was determined for Persian PREE. The Persian PREE exhibited promising validity and reliability. The findings supported its applicability in clinical situations that were consistent with the original version.
Stoyanova, Rumyana; Dimova, Rositsa; Tarnovska, Miglena; Boeva, Tatyana
2018-05-20
Patient safety (PS) is one of the essential elements of health care quality and a priority of healthcare systems in most countries. Thus the creation of validated instruments and the implementation of systems that measure patient safety are considered to be of great importance worldwide. The present paper aims to illustrate the process of linguistic validation, cross-cultural verification and adaptation of the Bulgarian version of the Hospital Survey on Patient Safety Culture (B-HSOPSC) and its test-retest reliability. The study design is cross-sectional. The HSOPSC questionnaire consists of 42 questions, grouped in 12 different subscales that measure patient safety culture. Internal con-sistency was assessed using Cronbach's alpha. The Wilcoxon signed-rank test and the split-half method were used; the Spear-man-Brown coefficient was calculated. The overall Cronbach's alpha for B-HSOPSC is 0.918. Subscales 7 Staffing and 12 Overall perceptions of safety had the lowest coefficients. The high reliability of the instrument was confirmed by the Split-half method (0.97) and ICC-coefficient (0.95). The lowest values of Spearmen-Broun coefficients were found in items A13 and A14. The study offers an analysis of the results of the linguistic validation of the B-HSOPSC and its test-retest reliability. The psychometric characteristics of the questions revealed good validity and reliability, except two questions. In the future, the instrument will be administered to the target population in the main study so that the psychometric properties of the instrument can be verified.
Mahmoudian, Amaneh; Torabi Chafjiri, Razieh; Alipour, Atefeh; Shamsalinia, Abbas; Ghaffari, Fatemeh
2018-01-01
Older adults with chronic disease are more vulnerable to abuse. Early and accurate detection of the elderly abuse phenomenon can help identify health-promoting solutions for the elderly, their family, and society. The purpose of this study was to design and evaluate the psychometric properties of a questionnaire on elderly abuse by family caregivers among older adults on hemodialysis. Qualitative and quantitative research methodologies were used to develop the questionnaire. The item pool was compiled from literature reviews and the Delphi method. The literature reviews comprised 22 studies. The psychometric properties of the questionnaire were verified using face, content, and construct validity, and the reliability was tested using Cronbach's alpha reliability. A 57-item questionnaire was developed after the psychometric evaluation. The Kaiser-Meyer-Olkin index and Bartlett's test of sphericity showed reliable results. Seven components from the exploratory content analysis including psychological misbehavior, authority deprivation, physical misbehavior, financial misbehavior, being abandoned, caring neglect, and emotional misbehavior explained 74.769% of the total variance. Cronbach's alpha was 0.98 and the interclass correlation coefficient was r =0.91 responding to the items twice ( p <0.001), which shows a high level of tool stability. This study developed a questionnaire to assess elderly abuse by family caregivers among older adults on hemodialysis. It is recommended as a mini scale that can be used both in statistical and practical studies, and that is valid and reliable. Nurses or other health care providers can use it in health centers, dialysis centers, or at the house of the patient.
Lin, Shike; Chaiear, Naesinee; Khiewyoo, Jiraporn; Wu, Bin; Johns, Nutjaree Pratheepawanit
2013-03-01
As quality of work-life (QWL) among nurses affects both patient care and institutional standards, assessment regarding QWL for the profession is important. Work-related Quality of Life Scale (WRQOLS) is a reliable QWL assessment tool for the nursing profession. To develop a Chinese version of the WRQOLS-2 and to examine its psychometric properties as an instrument to assess QWL for the nursing profession in China. Forward and back translating procedures were used to develop the Chinese version of WRQOLS-2. Six nursing experts participated in content validity evaluation and 352 registered nurses (RNs) participated in the tests. After a two-week interval, 70 of the RNs were retested. Structural validity was examined by principal components analysis and the Cronbach's alphas calculated. The respective independent sample t-test and intra-class correlation coefficient were used to analyze known-group validity and test-retest reliability. One item was rephrased for adaptation to Chinese organizational cultures. The content validity index of the scale was 0.98. Principal components analysis resulted in a seven-factor model, accounting for 62% of total variance, with Cronbach's alphas for subscales ranging from 0.71 to 0.88. Known-group validity was established in the assessment results of the participants in permanent employment vs. contract employment (t = 2.895, p < 0.01). Good test-retest reliability was observed (r = 0.88, p < 0.01). The translated Chinese version of the WRQOLS-2 has sufficient validity and reliability so that it can be used to evaluate the QWL among nurses in mainland China.
Reinfjell, Trude; Diseth, Trond H; Veenstra, Marijke; Vikan, Arne
2006-09-14
Health-Related Quality of Life (HRQOL) studies concerning children and adolescents are a growing field of research. The Pediatric Quality of Life Inventory (PedsQL) is considered as a promising HRQOL instrument with the availability of age appropriate versions and parallel forms for both child and parents. The purpose of the current study was to evaluate the psychometric properties of the Norwegian translation of the Pediatric Quality of Life Inventory (PedsQL) 4.0 generic core scale in a sample of healthy young adolescents. A cross-sectional study of 425 healthy young adolescents and 237 of their caregivers participating as a proxy. Reliability was assessed by Cronbach's alpha. Construct validity was assessed using exploratory factor analysis and by exploring the intercorrelations between and among the four PedsQL subscales for adolescents and their parents. All the self-report scales and proxy-report scales showed satisfactory reliability with Cronbach's alpha varying between 0.77 and 0.88. Factor analysis showed results comparable with the original version, except for the Physical Health scale. On average, monotrait-multimethod correlations were higher than multitrait-multimethod correlations. Sex differences were noted on the emotional functioning subscale, girls reported lower HRQOL than boys. The Norwegian PedsQL is a valid and reliable generic pediatric health-related Quality of Life measurement that can be recommended for self-reports and proxy-reports for children in the age groups ranging from 13-15 years.
Fearon, A M; Ganderton, C; Scarvell, J M; Smith, P N; Neeman, T; Nash, C; Cook, J L
2015-12-01
Greater trochanteric pain syndrome (GTPS) is common, resulting in significant pain and disability. There is no condition specific outcome score to evaluate the degree of severity of disability associated with GTPS in patients with this condition. To develop a reliable and valid outcome measurement capable of evaluating the severity of disability associated with GTPS. A phenomenological framework using in-depth semi structured interviews of patients and medical experts, and focus groups of physiotherapists was used in the item generation. Item and format clarification was undertaken via piloting. Multivariate analysis provided the basis for item reduction. The resultant VISA-G was tested for reliability with the inter class co-efficient (ICC), internal consistency (Cronbach's Alpha), and construct validity (correlation co-efficient) on 52 naïve participants with GTPS and 31 asymptomatic participants. The resultant outcome measurement tool is consistent in style with existing tendinopathy outcome measurement tools, namely the suite of VISA scores. The VISA-G was found to be have a test-retest reliability of ICC2,1 (95% CI) of 0.827 (0.638-0.923). Internal consistency was high with a Cronbach's Alpha of 0.809. Construct validity was demonstrated: the VISA-G measures different constructs than tools previously used in assessing GTPS, the Harris Hip Score and the Oswestry Disability Index (Spearman Rho:0.020 and 0.0205 respectively). The VISA-G did not demonstrate any floor or ceiling effect in symptomatic participants. The VISA-G is a reliable and valid score for measuring the severity of disability associated GTPS. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kim, Eun-Young; Yeo, Jung Hee; Park, Hyunjeong; Sin, Kyung Mi; Jones, Cheryl B
2018-02-01
Reality shock is a critical representation of the gap between nursing education and clinical practice and it is important to explore the level of reality shock among nurses. However, there is no relevant instrument to assess the level of reality shock in South Korea. The purpose of this is to determine the validity and reliability of the Korean version of the Environmental Reality Shock-Related Issues and Concerns instrument. A cross-sectional study design was used in this study. The data collection was conducted in selected 15 hospitals in South Korea. A convenience sample of 216 newly graduated nurses participated in the study. The Korean version of the Environmental Reality Shock-Related Issues and Concerns instrument was developed through the forward-backward translation technique, and revision based on feedback from expert groups. The internal consistency reliability was assessed using Cronbach's alpha, and the construct validity was determined via exploratory and confirmatory factor analysis. The Korean version of the Environmental Reality Shock-Related Issues and Concerns has reliable internal consistency (Cronbach's alpha=0.91). Exploratory factor analysis revealed five factors including job, relationships, expectations, private life, and performance, which explained 61.92% of variance. The factor loadings ranged from 0.451 to 0.832. The five-factor structure was validated by confirmatory factor analysis (RMR<0.05, CFI>0.9). It was concluded that the Korean version of the Environmental Reality Shock-Related Issues and Concerns instrument has satisfactory construct validity and reliability to measure the reality shock of newly graduated nurses in South Korea. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ruiz, Begoña; Urzúa, Iván; Cabello, Rodrigo; Rodríguez, Gonzalo; Espelid, Ivar
2013-01-01
To translate and validate a Spanish version of the "Questionnaire on the treatment of approximal and occlusal caries" as a method of collecting information about treatment decisions on caries management in Chilean primary health care services. The original questionnaire proposed by Espelid et al. was translated into Spanish using the forward-backward translation technique. Subsequently, validation of the Spanish version was undertaken. Data were collected from two separate samples; first, from 132 Spanish-speaking dentists recruited from primary health care services and second, from 21 individuals characterised as cariologists. Internal consistency was evaluated by the generation of Cronbach's alpha, test-retest reliability was evaluated by Cohen's kappa, convergent validity was evaluated by comparing the total scale scores to a global evaluation of treatment trends and discriminant validity was evaluated by investigating the differences in total scale scores between the Spanish-speaking dentist and cariologist samples. Cronbach's alpha indicated an internal consistency of 0.63 for the entire scale. Cohen's kappa correlation coefficient expressed a test-retest reliability of 0.83. Convergent validity determined a Pearson's correlation coefficient of 0.24 (p < 0.01). The comparison of proportions (chi-squared) indicated that discriminant validity was statistically significant (p < 0.01), using a one-tailed test. The Spanish version of the "Questionnaire on the treatment of approximal and occlusal caries" is a valid and reliable instrument for collecting information regarding treatment decisions in cariology. The clinical relevance of this study is to acquire a reliable instrument that allows for the determination of treatment decisions in Spanish-speaking dentists.
Creation of the TXP parenting questionnaire and study of its psychometric properties.
Benito, Ana; Calvo, Gema; Real-López, Matías; Gallego, María José; Francés, Sonia; Turbi, Ángel; Haro, Gonzalo
2018-01-15
Parenting is linked to conduct disorders (CD) and substance related disorders (SRD) in adolescents, but with differences according to cultural context. A questionnaire with two versions (parenting questionnaire TXP-A for adolescents and TXP-C for primary caregivers) was designed using the Delphi method to evaluate parenting practices related to CD and SRD in a Spanish population. It was validated in a community sample of 631 adolescents aged between 14 and 16 and their caregivers. Results suggest a 29-item TXP-A questionnaire with bifactorial structure: affection-communication and control-structure, with high internal (Cronbach’s alpha=0.89) and test-retest (intraclass correlation coefficient=0.94) reliabilities. Both factors are related to SRD (r=0.273, p<0.001) and with most of the psychopathological dimensions studied. The total score and affection-communication are related to dissocial disorder (t=3.259, p=0.001) and its severity (r=-0,119; p=0.003). Inter-observer reliability between adolescents and caregivers is low, in part because the 16-item TXP-C has a different bifactorial structure: affection-communication and prosocial values. TXP-C’s internal (Cronbach’s alpha=0.87) and test-retest (intraclass correlation coefficient=0.94) reliabilities are high. The total score and affection-communication were related to dissocial disorder (t=2.586; p=0.010) but TXP-C did not discriminate according to SRD. In conclusion, the TXP-A questionnaire for adolescents seems to be a reliable, valid and unbiased instrument that evaluates the perception of parenting practices, relating higher affection-communication and control-structure to less psychopathology and alcohol and drug use. TXP-C also seems to be reliable and unbiased, but shows less evidence of validity regarding substance use and psychopathology. .
Pourmarzi, Davoud; Khoramirad, Ashraf; Ahmari Tehran, Hoda; Abedini, Zahra
2015-11-01
To assess the perceived HIV/AIDS related stigma a comprehensive and well developed stigma instrument is necessary. This study aimed to assess validity and reliability of the Persian version of HIV/AIDS related stigma scale which was developed by Kang et al for people living with HIV/AIDS in Iran. Thescale was forward translatedby two bilingual academic members then both translations were discussed by expert team. Back-translation was done by two other bilingual translators then we carried out discussion with both of them. To evaluate understandability the scale was administered to 10 Persons Living with HIV/AIDS (PLWHA). Final Persian version was administered to 80 PLWHA in Qom, Iran in 2014. Test-retest reliability was assessed in a sample of 20 PLWHA after a week by intra-class correlation coefficient (ICC). Cronbach's alpha coefficient for overall scale was 0.85. Also Cronbach's alpha coefficients for the five subscales were as follows: social rejection (9 items, α = 0.84), negative self-worth (4 items, α = 0.70), perceived interpersonal insecurity (2 items, α = 0.57), financial insecurity (3 items, α = 0.70), discretionary disclosure (2 items, α = 0.83). Test-retest reliability was also approved with ICC = 0.78. Correlation between items and their hypothesized subscale is greater than 0.5. Correlation between an item and its own subscale was significantly higher than its correlation with other subscales. This study demonstrate that the Persian version of HIV/AIDS related stigma scale is valid and reliable to assess HIV/AIDS related stigma perceived by people living whit HIV/AIDS in Iran.
Assessment of psychometric properties of a modified PHEEM questionnaire.
Gooneratne, I K; Munasinghe, S R; Siriwardena, C; Olupeliyawa, A M; Karunathilake, I
2008-12-01
An effective tool in analysing the learning environment, customised to the Sri Lankan setting, is vital for the assessment and delivery of quality healthcare training of preregistration house officers. Such a tool should be reliable and valid. We assessed psychometric properties such as internal reliability and construct validity of a modified version of the Postgraduate Hospital Educational Environment Measure (PHEEM). A modified PHEEM questionnaire customised to the Sri Lankan context was developed in accordance to the Sri Lanka Medical Council guidelines. The questionnaire was distributed to all interns at the National Hospital of Sri Lanka, Colombo North Teaching Hospital and Wathupitiwala Base Hospital during a calendar year (n = 100, response rate = 86%). Internal reliability and construct validity of the inventory were assessed by using Cronbach's alpha and exploratory factor analysis respectively as statistical methods. PHEEM consists of 3 subscales: perceptions of autonomy, social support and teaching, which are factors perceived to be influencing the educational environment. This administration demonstrated high internal reliability as reflected by a Cronbach's alpha value of 0.84. Exploratory factor analysis identified 12 factors with eigenvalue >1. However, the first factor had an eigenvalue of 6.7 (accounting for 19.7% of variance), while the rest had eigenvalues < 2.5. These results suggest a single predictive factor and thus a one-dimensional scale as opposed to the three-dimensional scale which is used in the current questionnaire. The psychometric properties of this tool reflect a high degree of internal reliability in assessing the educational environment of intern doctors in Sri Lanka. It is possible that the clinical educational environment is collectively represented as a single dimension. This may be due to the complex interplay between individual items in the questionnaire. Therefore the psychometric properties do not justify the interpretation of the educational environment through specified subscales.
Test-retest reliability of the Mandarin versions of the Hypertension Self-Care Profile instrument.
Ngoh, Soh Heng Agnes; Lim, Hazel Wai Ling; Koh, Yi Ling Eileen; Tan, Ngiap Chuan
2017-11-01
Self-efficacy in essential hypertension can be measured using scales, such as the "Hypertension Self-Care Profile" (HTN-SCP) questionnaire. It assesses "Behavior", "Motivation", and "Self-efficacy" in 3 domains, respectively. This study aimed to validate the Mandarin version of HTN-SCP instrument (HTN-SCP-Mn) targeted at patients of Chinese ethnicity with hypertension.Our study recruited Chinese patients, aged 40 years and older, with essential hypertension from a public primary healthcare clinic in Singapore. The 60-item HTN-SCP-Mn questionnaire was completed online using a tablet or smartphone on enrolment. A retest was conducted 2 weeks after the initial test. Reliability was assessed by internal consistency and test-retest reliability using Cronbach alpha and intraclass correlation coefficients (ICC). Differences between the overall HTN-SCP-Mn scores of the patients and their self-reported self-management activities were also determined using independent t test.Of the 153 patients who completed the HTN-SCP-Mn during the initial test, 79 responded to the test-retest evaluation. Reliability of the 3 domains "Behavior", "Motivation", and "Self-efficacy" obtained high internal consistency (Cronbach alpha = 0.838, 0.929, and 0.927, respectively). The item total correlation ranged from 0.058 to 0.677 for Behavior, 0.374 to 0.798 for Motivation, and 0.326 to 0.767 for self-efficacy. The ICC indicated fair to good test-retest reliability with scores of 0.643, 0.579, and 0.710 for the respective domains.The results showed face validity of the HTN-SCP-Mn instrument, indicating its potential application in mandarin-proficient patients. Further study is needed to correlate its scores with objective demonstration of self-efficacy.
Oren, Besey; Zengin, Neriman; Yildiz, Nebahat
2016-01-01
This study aimed to test the validity and reliability of a version of the tool developed in Sri Lanka in 2011 to assess patient perceptions of the quality of nursing care and related hospital services created for use with Turkish patients. This methodological study was conducted between November 2013 and November 2014 after obtaining ethical approval and organizational permission. Data was collected during discharge from 180 adult patients who were hospitalized for at least 3 days at a medical school hospital located in Istanbul. After language validation, validity and reliability analyses of the scale were conducted. Content validity, content validity index (CVI), construct validity, and exploratory factor analysis were assessed and examined, and reliability was tested using the Cronbach's alpha coefficient and item-total correlations. Mean CVI was found to be 0.95, which is above expected value. Exploratory factor analysis revealed 4 factors with eigenvalues above 1, which explained 82.4% of total variance in the Turkish version of the tool to measure patient perceptions of nursing care and other hospital services. Factor loading for each item was ≥.40. Cronbach's alpha coefficient of sub-dimensions and total scale were found to be 0.84-0.98 and 0.98, respectively. Item-total correlations ranged from 0.56 to 0.83 for the entire group, which was above expected values. The Turkish version of the scale to assess patient perceptions of the quality of nursing care and related hospital services, which comprised 4 sub-dimensions and 36 items, was found to be valid and reliable for use with the Turkish population.
Singh, Varun Pratap; Singh, Rajkumar
2014-03-01
The aim of this study was to develop a reliable and valid Nepali version of the Psychosocial Impact of Dental Aesthetic Questionnaire (PIDAQ). Cross-sectional descriptive validation study. B.P. Koirala Institute of Health Sciences, Dharan, Nepal. A rigorous translation process including conceptual and semantic evaluation, translation, back translation and pre-testing was carried out. Two hundred and fifty-two undergraduates, including equal numbers of males and females with an age ranging from 18 to 29 years (mean age: 22·33±2·114 years), participated in this study. Reliability was assessed by Cronbach's alpha coefficient and the coefficient of correlation was used to assess correlation between items and test-retest reliability. The construct validity was tested by factorial analysis. Convergent construct validity was tested by comparison of PIDAQ scores with the aesthetic component of the index of orthodontic treatment needs (IOTN-AC) and perception of occlusion scale (POS), respectively. Discriminant construct validity was assessed by differences in score for those who demand treatment and those who did not. The response rate was 100%. One hundred and twenty-three individuals had a demand for orthodontic treatment. The Nepali PIDAQ had excellent reliability with Cronbach's alpha of 0·945, corrected item correlation between 0·525 and 0·790 and overall test-retest reliability of 0·978. The construct validity was good with formation of a new sub-domain 'Dental self-consciousness'. The scale had good correlation with IOTN-AC and POS fulfilling convergent construct validity. The discriminant construct validity was proved by significant differences in scores for subjects with demand and without demand for treatment. To conclude, Nepali version of PIDAQ has good psychometric properties and can be used effectively in this population group for further research.
Cross-cultural adaptation of VISA-P score for patellar tendinopathy in Turkish population.
Çelebi, Mehmet Mesut; Köse, Serdal Kenan; Akkaya, Zehra; Zergeroglu, Ali Murat
2016-01-01
VISA-P questionnaire assesses to severity of symptoms and treatment effects in athletes with patellar tendinopathy. The purpose of this study was to translated VISA-P questionnaire into Turkish language and to determine its validity and reliability. The English version of VISA-P questionnaire was translated into Turkish according to the internationally recommended guidelines. Test-retest reliability was determined on 89 participants with time interval 24 h. To determine validity of Turkish VISA-P, 31 (17 male, 14 female) healthy students, 34 (20 male, 14 female) patients with patellar tendinopathy (diagnosed by physical examination and ultrasonography) and 24 (16 male, 8 female) volleyball players (at risk populations) were completed VISA-P-Tr. Internal consistency was determined with Cronbach's alpha. Intraclass correlation coefficients (ICCs) were calculated to analyse test-retest reliability. To assessment of discrimination, VISA-P-Tr scores compared all groups using the Mann-Whitney-U test. The VISA-P-Tr questionnaire showed good test-retest reliability (The Cronbach's alpha was 0.79 and 0.78 respectively and ICC was 0.96). The VISA-P-Tr score (mean ± SD) were 93.7 ± 8.9 and 94.0 ± 8.1 for healthy students, 81.1 ± 13.7 and 80.7 ± 13.4 for volleyball players, 58.8 ± 12.1 and 58.5 ± 11.0 for athletes with patellar tendinopathy. The translated Turkish version of VISA-P has good internal consistency and good reliability and validity. Therefore VISA-P-Tr is useful to evaluate symptoms and follow the treatment effect in athletes with patellar tendinopathy.
[An instrument in Spanish to evaluate the performance of clinical teachers by students].
Bitran, Marcela; Mena, Beltrán; Riquelme, Arnoldo; Padilla, Oslando; Sánchez, Ignacio; Moreno, Rodrigo
2010-06-01
The modernization of clinical teaching has called for the creation of faculty development programs, and the design of suitable instruments to evaluate clinical teachers' performance. To report the development and validation of an instrument in Spanish designed to measure the students' perceptions of their clinical teachers' performance and to provide them with feedback to improve their teaching practices. In a process that included the active participation of authorities, professors in charge of courses and internships, clinical teachers, students and medical education experts, we developed a 30-item questionnaire called MEDUC30 to evaluate the performance of clinical teachers by their students. The internal validity was assessed by factor analysis of 5214 evaluations of 265 teachers, gathered from 2004 to 2007. The reliability was measured with the Cronbach's alpha coefficient and the generalizability coefficient (g). MEDUC30 had good content and construct validity. Its internal structure was compatible with four factors: patient-centered teaching, teaching skills, assessment skills and learning climate, and it proved to be consistent with the structure anticipated by the theory. The scores were highly reliable (Cronbach's alpha: 0.97); five evaluations per teacher were sufficient to reach a reliability coefficient (g) of 0.8. MEDUC30 is a valid, reliable and useful instrument to evaluate the performance of clinical teachers. To our knowledge, this is the first instrument in Spanish for which solid validity and reliability evidences have been reported. We hope that MEDUC30 will be used to improve medical education in Spanish-speaking medical schools, providing teachers a specific feedback upon which to improve their pedagogical practice, and authorities with valuable information for the assessment of their faculty.
Reliability and validity of the Nurse Practitioners' Roles and Competencies Scale.
Lin, Li-Chun; Lee, Sheuan; Ueng, Steve Wen-Neng; Tang, Woung-Ru
2016-01-01
The objective of this study was to test the reliability and construct validity of the Nurse Practitioners' Roles and Competencies Scale. The role of nurse practitioners has attracted international attention. The advanced nursing role played by nurse practitioners varies with national conditions and medical environments. To date, no suitable measurement tool has been available for assessing the roles and competencies of nurse practitioners in Asian countries. Secondary analysis of data from three studies related to nurse practitioners' role competencies. We analysed data from 563 valid questionnaires completed in three studies to identify the factor structure of the Nurse Practitioners' Roles and Competencies Scale. To this end, we performed exploratory factor analysis using principal component analysis extraction with varimax orthogonal rotation. The internal consistency reliabilities of the overall scale and its subscales were examined using Cronbach's alpha coefficient. The scale had six factors: professionalism, direct care, clinical research, practical guidance, medical assistance, as well as leadership and reform. These factors explained 67·5% of the total variance in nurse practitioners' role competencies. Cronbach's alpha coefficient for the overall scale was 0·98, and those of its subscales ranged from 0·83-0·97. The internal consistency reliability and construct validity of the Nurse Practitioners' Roles and Competencies Scale were good. The high internal consistency reliabilities suggest item redundancy, which should be minimised by using item response theory to enhance the applicability of this questionnaire for future academic and clinical studies. The Nurse Practitioners' Roles and Competencies Scale can be used as a tool for assessing the roles and competencies of nurse practitioners in Taiwan. Our findings can also serve as a reference for other Asian countries to develop the nurse practitioner role. © 2015 John Wiley & Sons Ltd.
van Dijk, Inge; Scholten Meilink Lenferink, Nick; Lucassen, Peter L B J; Mercer, Stewart W; van Weel, Chris; Olde Hartman, Tim C; Speckens, Anne E M
2017-02-01
Empathy is an essential skill in doctor-patient communication with positive effects on compliance, patient satisfaction and symptom duration. There are no validated patient-rated empathy measures available in Dutch. To investigate the validity and reliability of a Dutch version of the Consultation and Relational Empathy (CARE) Measure, a widely used 10-item patient-rated questionnaire of physician empathy. After translation and back translation, the Dutch CARE Measure was distributed among patients from 19 general practitioners in 5 primary care centers. Tests of internal reliability and validity included Cronbach's alpha, item total correlations and factor analysis. Seven items of the QUality Of care Through the patient's Eyes (QUOTE) questionnaire assessing 'affective performance' of the physician were included in factor analysis and used to investigate convergent validity. Of the 800 distributed questionnaires, 655 (82%) were returned. Acceptability and face validity were supported by a low number of 'does not apply' responses (range 0.2%-11.9%). Internal reliability was high (Cronbach's alpha 0.974). Corrected item total correlations were at a minimum of 0.837. Factor analysis on the 10 items of the CARE Measure and 7 QUOTE items resulted in two factors (Eigenvalue > 1), the first containing the CARE Measure items and the second containing the QUOTE items. Convergent construct validity between the CARE Measure and QUOTE was confirmed with a modest positive correlation (r = 0.34, n = 654, P < 0.001). The findings support the preliminary validity and reliability of the Dutch CARE Measure. Future research is required to investigate divergent validity and discriminant ability between doctors. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Nikjooy, Afsaneh; Jafari, Hassan; Saba, Maryam A; Ebrahimi, Naghmeh; Mirzaei, Rezvan
2018-05-01
The Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire is the most validated and the most specific tool for measuring the quality of life of patients with constipation. Over 120 million people live in countries whose official language is Persian. There is no reported Persian version of the PAC-QOL questionnaire yet. The aim of this study was to translate and culturally adapt the PAC-QOL questionnaire and to assess its reliability and validity among Persian patients with chronic constipation. Following the translation and cultural adaptation of the PAC-QOL questionnaire to Persian, 100 patients (mean±SD age=40.51±13.67) with constipation were recruited for validity measurement and 20 patients were re-examined for reliability. Content validity was assessed based on the opinions of an expert committee and the floor/ceiling effect. Construct validity was evaluated according to the hypothesis test. The SF-36 questionnaire was used for concurrent criterion validity, intra-class correlation coefficient for reliability, and Cronbach's alpha for internal consistency. The content validity of the PAC-QOL questionnaire was proven, and there was no floor/ceiling effect. Construct validity also was confirmed based on the hypothesis test. The overall Cronbach's alpha of the PAC-QOL questionnaire was 0.92 (range=0.72-0.92), and the overall intra-class correlation coefficient of the questionnaire was 0.88 (range=0.69-0.87). The correlation between the SF-36 and PAC-QOL questionnaires was moderate. The Persian version of the PAC-QOL questionnaire demonstrated good validity and reliability properties in chronic constipation. Accordingly, Persian researchers and clinicians can benefit from this questionnaire in further research and assessment of treatment outcomes.
Çelik, Derya; Can, Canan; Aslan, Yasemin; Ceylan, Hasan Huseyin; Bilsel, Kerem; Ozdincler, Arzu Razak
2014-01-01
The Harris Hip Score (HHS) developed to assess function and pain from the perspective of patients hip pathologies. The purpose of this study was to translate and culturally adapt the HHS into Turkish, and thereby determine the reliability and validity of the translated version. The HHS was translated into Turkish in accordance with the stages recommended by Beaton. The measurement properties of the HHS were tested in 80 patients; 52 males, mean age 51 years (range 21-75 years) suffering from different hip pathologies. The test-retest reliability was tested in 58 patients; 28 males mean age, 52 years (range 30-73 years) after an interval of seven days. The Cronbach's Alpha was used to assess internal consistency and the intra-class correlation coefficient (ICC) was used to estimate the test-retest reliability. Patients were asked to answer the Oxford Hip Score (OHS), the Western Ontario and McMaster Universities Arthritis Index (WOMAC), the VAS and the Short Form-36 (SF-36) for the validity of the estimation. The Turkish version of the HHS showed sufficient internal consistency (Cronbach's alpha,0.70) and test-retest reliability (ICC = 0.91). The correlation coefficients between the HHS, the WOMAC and the OHS were 0.64 and 0.89 respectively. The highest correlations between the HHS and SF-36 were with the physical function scale (r = 0.72), and the lowest correlations were with the mental function scale (r = 0.10). We observed no floor or ceiling effects. The Turkish version of the HHS has sufficient reliability and validity to measure patient-reported outcome for Turkish-speaking individuals with a variety of hip disorders.
Validity and reliability of the Persian version of mobile phone addiction scale.
Mazaheri, Maryam Amidi; Karbasi, Mojtaba
2014-02-01
With regard to large number of mobile users especially among college students in Iran, addiction to mobile phone is attracting increasing concern. There is an urgent need for reliable and valid instrument to measure this phenomenon. This study examines validity and reliability of the Persian version of mobile phone addiction scale (MPAIS) in college students. this methodological study was down in Isfahan University of Medical Sciences. One thousand one hundred and eighty students were selected by convenience sampling. The English version of the MPAI questionnaire was translated into Persian with the approach of Jones et al. (Challenges in language, culture, and modality: Translating English measures into American Sign Language. Nurs Res 2006; 55: 75-81). Its reliability was tested by Cronbach's alpha and its dimensionality validity was evaluated using Pearson correlation coefficients with other measures of mobile phone use and IAT. Construct validity was evaluated using Exploratory subscale analysis. Cronbach's alpha of 0.86 was obtained for total PMPAS, for subscale1 (eight items) was 0.84, for subscale 2 (five items) was 0.81 and for subscale 3 (two items) was 0.77. There were significantly positive correlations between the score of PMPAS and IAT (r = 0.453, P < 0.001) and other measures of mobile phone use. Principal component subscale analysis yielded a three-subscale structure including: inability to control craving; feeling anxious and lost; mood improvement accounted for 60.57% of total variance. The results of discriminate validity showed that all the item's correlations with related subscale were greater than 0.5 and correlations with unrelated subscale were less than 0.5. Considering lack of a valid and reliable questionnaire for measuring addiction to the mobile phone, PMPAS could be a suitable instrument for measuring mobile phone addiction in future research.
Gallasch, Cristiane Helena; Alexandre, Neusa Maria Costa; Amick, Benjamin
2007-12-01
The study objectives were to translate and adapt the Work Role Functioning Questionnaire (WRFQ) into the Brazilian Portuguese language and evaluate its reliability in patients experiencing musculoskeletal disorders. The cross-cultural adaptation was performed according to the internationally recommended methodology, using the following guidelines: translation, back-translation, revision by a committee, and pretest. At first, the questionnaire was independently translated by two bilingual translators, who had Portuguese as their mother language. Subsequently, two other translators whose mother language was English did the back-translation. A committee composed of five specialists revised and compared the translations obtained, developing the final version for pretest application. The pretest was carried out with 30 patients experiencing musculoskeletal disorders. Psychometric properties were evaluated by administering the questionnaire to 105 subjects with musculoskeletal disorders and receiving physical therapy treatment. The reliability was estimated through stability and homogeneity assessment. The construct validity was tested comparing subjects experiencing musculoskeletal disorders to healthy workers. The results indicated good content validity and internal consistency (Cronbach alpha = 0.95). Cronbach alpha for each scale was >0.85, except for the social demand scale. The Intraclass Correlation Coefficient for the test-retest reliability was satisfactory for mental demands (ICC = 0.68) and excellent for the others (0.82-0.91). In relation to the construct validity, the mean score obtained for each scale was lower for physical, work scheduling, and output demands in the subjects with musculoskeletal disorders. There was a significant difference (p < 0.001) between the groups in comparison to work scheduling, physical, and output demands. The data showed that the cross-cultural adaptation process was successful and the adapted instrument demonstrated psychometric properties making it reliable to use in Brazilian culture.
Test-retest reliability of the Military Pre-training Questionnaire.
Robinson, M; Stokes, K; Bilzon, J; Standage, M; Brown, P; Thompson, D
2010-09-01
Musculoskeletal injuries are a significant cause of morbidity during military training. A brief, inexpensive and user-friendly tool that demonstrates reliability and validity is warranted to effectively monitor the relationship between multiple predictor variables and injury incidence in military populations. To examine the test-retest reliability of the Military Pre-training Questionnaire (MPQ), designed specifically to assess risk factors for injury among military trainees across five domains (physical activity, injury history, diet, alcohol and smoking). Analyses were based on a convenience sample of 58 male British Army trainees. Kappa (kappa), weighted kappa (kappa(w)) and intraclass correlation coefficients (ICC) were used to evaluate the 2-week test-retest reliability of the MPQ. For index measures constituting the assessment of a given construct, internal consistency was assessed by Cronbach's alpha (alpha) coefficients. Reliability of individual items ranged from poor to almost perfect (kappa range = 0.45-0.86; kappa(w) range = 0.11-0.91; ICC range = 0.34-0.86) with most items demonstrating moderate reliability. Overall scores related to physical activity, diet, alcohol and smoking constructs were reliable between both administrations (ICC = 0.63-0.85). Support for the internal consistency of the incorporated alcohol (alpha = 0.78) and cigarette (alpha = 0.75) scales was also provided. The MPQ is a reliable self-report instrument for assessing multiple injury-related risk factors during initial military training. Further assessment of the psychometric properties of the MPQ (e.g. different types of validity) with military populations/samples will support its interpretation and use in future surveillance and epidemiological studies.
Validation of a combined health literacy and numeracy instrument for patients with type 2 diabetes.
Luo, Huabin; Patil, Shivajirao P; Wu, Qiang; Bell, Ronny A; Cummings, Doyle M; Adams, Alyssa D; Hambidge, Bertha; Craven, Kay; Gao, Fei
2018-05-20
This study aimed to validate a new consolidated measure of health literacy and numeracy (health literacy scale [HLS] plus the subjective numeracy scale [SNS]) in patients with type 2 diabetes (T2DM). A convenience sample (N = 102) of patients with T2DM was recruited from an academic family medicine center in the southeastern US between September-December 2017. Participants completed a questionnaire that included the composite HLS/SNS (22 questions) and a commonly used objective measure of health literacy-S-TOFHLA (40 questions). Internal reliability of the HLS/SNS was assessed using Cronbach's alpha. Criterion and construct validity was assessed against the S-TOFHLA. The composite HLS/SNS had good internal reliability (Cronbach's alpha = 0.83). A confirmatory factor analysis revealed there were four factors in the new instrument. Model fit indices showed good model-data fit (RMSEA = 0.08). The Spearman's rank order correlation coefficient between the HLS/SNS and the S-TOFHLA was 0.45 (p < 0.01). Our study suggests that the composite HLS/SNS is a reliable, valid instrument. Published by Elsevier B.V.
Zhang, Zhiyong; Yuan, Ke-Hai
2016-06-01
Cronbach's coefficient alpha is a widely used reliability measure in social, behavioral, and education sciences. It is reported in nearly every study that involves measuring a construct through multiple items. With non-tau-equivalent items, McDonald's omega has been used as a popular alternative to alpha in the literature. Traditional estimation methods for alpha and omega often implicitly assume that data are complete and normally distributed. This study proposes robust procedures to estimate both alpha and omega as well as corresponding standard errors and confidence intervals from samples that may contain potential outlying observations and missing values. The influence of outlying observations and missing data on the estimates of alpha and omega is investigated through two simulation studies. Results show that the newly developed robust method yields substantially improved alpha and omega estimates as well as better coverage rates of confidence intervals than the conventional nonrobust method. An R package coefficientalpha is developed and demonstrated to obtain robust estimates of alpha and omega.
Satisfaction With Appearance Scale-SWAP: Adaptation and validation for Brazilian burn victims.
Caltran, Marina P; Freitas, Noélle O; Dantas, Rosana A S; Farina, Jayme Adriano; Rossi, Lidia A
2016-09-01
Methodological study that aimed to adapt the Satisfaction with Appearance Scale (SWAP) into Brazilian Portuguese language and to assess the validity, the reliability and the dimensionality of the adapted version in a sample of Brazilian burn victims. We carried out the adaptation process according to the international literature. Construct validity was assessed by correlating the adapted version of SWAP scores with depression (Beck Depression Index), self-esteem (Rosenberg Self-Esteem Scale), health-related quality of Life (Short Form Health Survey-36) and health status of burn victims (Burn Specific Health Scale-Revised), and with gender, total body surface area burned, and visibility of the scars. We tested dimensionality using Exploratory Factor Analysis (EFA) and the reliability by means of Cronbach's alpha. Participants were 106 adult burned patients. The correlations between the Brazilian version of the SWAP scores and the correlated construct measures varied from moderate to strong (r=.30-.77). The participants who perceived their burn sequelae was visible reported being more dissatisfied with their body image than the participants who answered that their scars would not be visible (p<.001). Cronbach's alpha for the adapted version was 0.88 and the item-total correlation varied from moderate to strong (r=.35-.73). The EFA resulted in three factors with a total explained variance percentage of 63.2%. The Brazilian version of the SWAP was valid and reliable for use with Brazilian burn victims. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Azari, Nadia; Soleimani, Farin; Vameghi, Roshanak; Sajedi, Firoozeh; Shahshahani, Soheila; Karimi, Hossein; Kraskian, Adis; Shahrokhi, Amin; Teymouri, Robab; Gharib, Masoud
2017-01-01
Bayley Scales of infant & toddler development is a well-known diagnostic developmental assessment tool for children aged 1-42 months. Our aim was investigating the validity & reliability of this scale in Persian speaking children. The method was descriptive-analytic. Translation- back translation and cultural adaptation was done. Content & face validity of translated scale was determined by experts' opinions. Overall, 403 children aged 1 to 42 months were recruited from health centers of Tehran, during years of 2013-2014 for developmental assessment in cognitive, communicative (receptive & expressive) and motor (fine & gross) domains. Reliability of scale was calculated through three methods; internal consistency using Cronbach's alpha coefficient, test-retest and interrater methods. Construct validity was calculated using factor analysis and comparison of the mean scores methods. Cultural and linguistic changes were made in items of all domains especially on communication subscale. Content and face validity of the test were approved by experts' opinions. Cronbach's alpha coefficient was above 0.74 in all domains. Pearson correlation coefficient in various domains, were ≥ 0.982 in test retest method, and ≥0.993 in inter-rater method. Construct validity of the test was approved by factor analysis. Moreover, the mean scores for the different age groups were compared and statistically significant differences were observed between mean scores of different age groups, that confirms validity of the test. The Bayley Scales of Infant and Toddler Development is a valid and reliable tool for child developmental assessment in Persian language children.
Pourmomeny, Abbas Ali; Rezaeian, Zahra Sadat; Soltanmohamadi, Mahsa
2017-09-01
The aim of this study was to evaluate the psychometric properties of the Persian version of the International Consultation on Incontinence Modular Questionnaire for Female Lower Urinary Tract Symptoms (ICIQ-FLUTS) in patients with urinary tract dysfunction. After gaining permission from the International Consultation on Incontinence Modular Questionnaire (ICIQ) advisory board, the English Female Lower Urinary Tract Symptoms (FLUTS) questionnaire was translated into Persian and then translated back into English. One hundred fourteen women with pelvic floor dysfunction were asked to complete the Persian FLUTS and International Consultation on Incontinence Modular Questionnaire Overactive Bladder Questionnaire (ICIQ-OAB). The Persian FLUTS questionnaire was also readministered to 20 patients 2 weeks after their initial visit. Study data were analyzed using SPSS V16.0. To validate the translated questionnaire, we assayed content/face validity, internal consistency/reliability, and construct validity. Internal consistency and test-retest reliability were assessed using Cronbach's alpha and the intraclass correlation coefficient (ICC) respectively. The mean age of the patients was 48.8 years old, 84% were married, and 59% had at least one Caesarean. Except for very few missing data, there is no any ambiguity in the Persian version of the FLUTS questionnaire. The Cronbach's alpha was 0.83, indicating a high internal consistency. Concerning criterion validity, correlation between the Persian FLUTS and the OAB was 0.77 (p < 0.001). The initial testing of the Persian version of the FLUTS questionnaire demonstrates good internal consistency, content validity, and reliability.
Psychometric Properties of the Persian Version of the Simple Shoulder Test (SST) Questionnaire.
Ebrahimzadeh, Mohammad H; Vahedi, Ehsan; Baradaran, Aslan; Birjandinejad, Ali; Seyyed-Hoseinian, Seyyed-Hadi; Bagheri, Farshid; Kachooei, Amir Reza
2016-10-01
To validate the Persian version of the simple shoulder test in patients with shoulder joint problems. Following Beaton`s guideline, translation and back translation was conducted. We reached to a consensus on the Persian version of SST. To test the face validity in a pilot study, the Persian SST was administered to 20 individuals with shoulder joint conditions. We enrolled 148 consecutive patients with shoulder problem to fill the Persian SST, shoulder specific measure including Oxford shoulder score (OSS) and two general measures including DASH and SF-36. To measure the test-retest reliability, 42 patients were randomly asked to fill the Persian-SST for the second time after one week. Cronbach's alpha coefficient was used to demonstrate internal consistency over the 12 items of Persian-SST. ICC for the total questionnaire was 0.61 showing good and acceptable test-retest reliability. ICC for individual items ranged from 0.32 to 0.79. The total Cronbach's alpha was 0.84 showing good internal consistency over the 12 items of the Persian-SST. Validity testing showed strong correlation between SST and OSS and DASH. The correlation with OSS was positive while with DASH scores was negative. The correlation was also good to strong with all physical and most mental subscales of the SF-36. Correlation coefficient was higher with DASH and OSS in compare to SF-36. Persian version of SST found to be valid and reliable instrument for shoulder joint pain and function assessment in Iranian population.
Cigarette dependence questionnaire: development and psychometric testing with male smokers.
Huang, Chih-Ling; Lin, Hsi-Hui; Wang, Hsiu-Hung
2010-10-01
This paper is a report of a study conducted to develop and test a theoretically derived Cigarette Dependence Questionnaire for adult male smokers. Fagerstrom questionnaires have been used worldwide to assess cigarette dependence. However, these assessments lack any theoretical perspective. A theory-based approach is needed to ensure valid assessment. In 2007, an initial pool of 103 Cigarette Dependence Questionnaire items was distributed to 109 adult smokers in Taiwan. Item analysis was conducted to select items for inclusion in the refined scale. The psychometric properties of the Cigarette Dependence Questionnaire were further evaluated 2007-08, when it was administered to 256 respondents and their saliva was collected and analysed for cotinine levels. Criterion validity was established through the Pearson correlation between the scale and saliva cotinine levels. Exploratory factor analysis was used to test construct validity. Reliability was determined with Cronbach's alpha coefficient and a 2-week test-retest coefficient. The selection of 30 items for seven perspectives was based on item analysis. One factor accounting for 44.9% of the variance emerged from the factor analysis. The factor was named as cigarette dependence. Cigarette Dependence Questionnaire scores were statistically significantly correlated with saliva cotinine levels (r = 0.21, P = 0.01). Cronbach's alpha was 0.95 and test-retest reliability using an intra-class correlation was 0.92. The Cigarette Dependence Questionnaire showed sound reliability and validity and could be used by nurses to set up smoking cessation interventions based on assessment of cigarette dependence. © 2010 Blackwell Publishing Ltd.
Parizi, Ahmad Shahabeddin; Garmaroudi, Gholamreza; Fazel, Mojtaba; Omidvari, Sepideh; Azin, Seyed Ali; Montazeri, Ali; Jafarpour, Saba
2014-09-01
Health-related quality of life (HRQOL), which is receiving increasing attention, is a multidimensional concept that encompasses different areas including the physiological, psychological, social, and spiritual aspects of life. The KIDSCREEN-52 questionnaire is designed to measure the HRQOL of 8-18-year-old children and adolescents. The aim of this study was to develop a Persian version of KIDSCREEN-52 and analyze the validity and reliability of the translated version. The KIDSCREEN-52 was translated into Persian in keeping with the international cross-cultural translation guidelines. A cross-sectional study was performed in the city of Tehran during 2012-2013. 328 students ranging in age from 8 to 18 years were enrolled in the study. The reliability for each dimension was estimated using Cronbach's alpha coefficient. To examine the validity of the questionnaire, a confirmatory factor analysis (CFA) was conducted. The Cronbach's alpha coefficient was higher than 0.7 in all ten dimensions except self-perception. Validity of this questionnaire was confirmed by CFA. (Relative chi square (χ (2)/df) = 1.73; root-mean-square error of approximation = 0.047; normed fit index = 0.93; Tucker-Lewis index = 0.97; comparative fit index = 0.97; and relative fit index = 0.92.) The Persian version of KIDSCREEN-52 is reliable and valid and can be used as a self-administered instrument for measuring HRQOL in children and adolescents in Iran.
Sexual behavioral abstine HIV/AIDS questionnaire: Validation study of an Iranian questionnaire
Najarkolaei, Fatemeh Rahmati; Niknami, Shamsaddin; Shokravi, Farkhondeh Amin; Tavafian, Sedigheh Sadat; Fesharaki, Mohammad Gholami; Jafari, Mohammad Reza
2014-01-01
Background: This study was designed to assess the validity and reliability of the designed sexual, behavioral abstinence, and avoidance of high-risk situation questionnaire (SBAHAQ), with an aim to construct an appropriate development tool in the Iranian population. Materials and Methods: A descriptive–analytic study was conducted among female undergraduate students of Tehran University, who were selected through cluster random sampling. After reviewing the questionnaires and investigating face and content validity, internal consistency of the questionnaire was assessed by Cronbach's alpha. Explanatory and confirmatory factor analysis was conducted using SPSS and AMOS 16 Software, respectively. Results: The sample consisted of 348 female university students with a mean age of 20.69 ± 1.63 years. The content validity ratio (CVR) coefficient was 0.85 and the reliability of each section of the questionnaire was as follows: Perceived benefit (PB; 0.87), behavioral intention (BI; 0.77), and self-efficacy (SE; 0.85) (Cronbach's alpha totally was 0.83). Explanatory factor analysis showed three factors, including SE, PB, and BI, with the total variance of 61% and Kaiser–Meyer–Olkin (KMO) index of 88%. These factors were also confirmed by confirmatory factor analysis [adjusted goodness of fitness index (AGFI) = 0.939, root mean square error of approximation (RMSEA) = 0.039]. Conclusion: This study showed the designed questionnaire provided adequate construct validity and reliability, and could be adequately used to measure sexual abstinence and avoidance of high-risk situations among female students. PMID:24741650
Questionnaire to assess patient satisfaction with pharmaceutical care in Spanish language.
Traverso, María Luz; Salamano, Mercedes; Botta, Carina; Colautti, Marisel; Palchik, Valeria; Pérez, Beatriz
2007-08-01
To develop and validate a questionnaire, in Spanish, for assessing patient satisfaction with pharmaceutical care received in community pharmacies. Selection and translation of questionnaire's items; definition of response scale and demographic questions. Evaluation of face and content validity, feasibility, factor structure, reliability and construct validity. Forty-one community pharmacies of the province of Santa Fe. Argentina. Questionnaire administered to patients receiving pharmaceutical care or traditional pharmacy services. Pilot test to assess feasibility. Factor analysis used principal components and varimax rotation. Reliability established using internal consistency with Cronbach's alpha. Construct validity determined with extreme group method. A self-administered questionnaire with 27 items, 5-point Likert response scale and demographic questions was designed considering multidimensional structure of patient satisfaction. Questionnaire evaluates cumulative experience of patients with comprehensive pharmaceutical care practice in community pharmacies. Two hundred and seventy-four complete questionnaires were obtained. Factor analysis resulted in three factors: Managing therapy, Interpersonal relationship and General satisfaction, with a cumulative variance of 62.51%. Cronbach's alpha for the whole questionnaire was 0.96, and 0.95, 0.88 and 0.76 for the three factors, respectively. Mann-Whitney test for construct validity did not showed significant differences between pharmacies that provide pharmaceutical care and those that do not, however, 23 items showed significant differences between the two groups of pharmacies. The questionnaire developed can be a reliable and valid instrument to assess patient satisfaction with pharmaceutical care in community pharmacies in Spanish. Further research is needed to deepen the validation process.
Vázquez Peña, Fernando; Harzheim, Erno; Terrasa, Sergio; Berra, Silvina
2017-02-01
To validate the Brazilian short version of the PCAT for adult patients in Spanish. Analysis of secondary data from studies made to validate the extended version of the PCAT questionnaire. City of Córdoba, Argentina. Primary health care. The sample consisted of 46% of parents, whose children were enrolled in secondary education in three institutes in the city of Cordoba, and the remaining 54% were adult users of the National University of Cordoba Health Insurance. Pearson's correlation coefficient comparing the extended and short versions. Goodness-of-fit indices in confirmatory factor analysis, composite reliability, average variance extracted, and Cronbach's alpha values, in order to assess the construct validity and the reliability of the short version. The values of Pearson's correlation coefficient between this short version and the long version were high .818 (P<.001), implying a very good criterion validity. The indicators of good global adjustment to the confirmatory factor analysis were good. The value of composite reliability was good (.802), but under the variance media extracted: .3306, since 3 variables had weak factorials loads. The Cronbach's alpha was acceptable (.85). The short version of the PCAT-users developed in Brazil showed an acceptable psychometric performance in Spanish as a quick assessment tool, in a comparative study with the extended version. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Quek, Kia Fatt; Chua, Chong Beng; Razack, Azad Hassan; Low, Wah Yun; Loh, Chit Sin
2005-01-01
The purpose of the present study was to validate the Mandarin version of the International Prostate Symptom Score (Mand-IPSS) in a Malaysian population. The validity and reliability were studied in patients with lower urinary tract symptoms (LUTS; benign prostatic hyperplasia [BPH] group) and without LUTS (control group). Test-retest methodology was used to assess the reliability while Cronbach alpha was used to assess the internal consistency. Sensitivity to change was used to express the effect size index in the preintervention versus post-intervention score in patients with LUTS who underwent transurethral resection of the prostate. For the control group and BPH group, the internal consistency was excellent and a high degree of internal consistency was observed for all seven items (Cronbach alpha = 0.86-0.98 and 0.90-0.98, respectively). Test-retest correlation coefficients for all items were highly significant. Intraclass correlation coefficient (ICC) was high for the control (ICC = 0.93-0.99) and BPH group (ICC = 0.91-0.99). The sensitivity and specificity showed a high degree of sensitivity and specificity to the effects of treatment. A high degree of significance between baseline and post-treatment scores was observed across all seven items in the BPH group but not in the control group. The Mand-IPSS is a suitable, reliable, valid and sensitive instrument to measure clinical change in the Malaysian population.
Validation of an adapted arabic version of fibromyalgia syndrome impact questionnaire.
El-Naby, Mai Abd; Hefny, Mohamed Ahmed; Fahim, Ayman Ekram; Awadalla, Magdy Ahmed
2013-10-01
Fibromyalgia (FM) is the most common chronic pain syndrome encountered in medical practice, affecting females more than males, and the estimated prevalence of FM in Egypt is 1.3 %. The aim was to translate and adapt the Fibromyalgia Impact Questionnaire (FIQ) into Arabic and assess reliability and validity. The Arabic version of Fibromyalgia Impact Questionnaire (FIQ-A) was adapted following the forward/backward translation approach. Fifty-one female patients with FM were studied to assess psychometric properties of the FIQ-A. Reliability was analyzed by the correlation coefficient between test and retest. Internal consistency was checked by the Cronbach's alpha coefficient. Construct validity was assessed comparing FIQ-A with Health Assessment Questionnaire (HAQ), Health Assessment Questionnaire of Fibromyalgia (FHAQ), The Medical Outcome Survey Short-Form-36 (SF-36), and the Total Visual Analog Scale (TVAS) for FM symptom, and feasibility was assessed by the time taken in completing the FIQ-A and the proportion of patients completed the questionnaire. Patients studied were 33.2 ± 9.8 years old. Translation was concordant. Adaptation affected 4 sub-items of physical function. Test-retest correlation coefficient was 0.89 for total FIQ-A and Cronbach's alpha was 0.76. Excellent to good statistically significant correlations (p < 0.05) were found between the FIQ-A items and HAQ, FHAQ, and SF-36. The FIQ-A is a reliable, valid for measuring health status and physical function in Arabic-speaking FM patients.
Reliability of the social skills rating system in a group of Iranian children.
Shahim, S
2001-12-01
The purpose of this study was to investigate reliability of the Social Skills Rating Systems of Gresham and Elliott for use in Iran. The sample consisted of 304 students aged 6 to 12 years, selected from the elementary schools in Shiraz, Iran. Parents' and teachers' ratings of social skills and behavioural problems and self-rating of social skills were applied in this study. Pearson correlations between parents' and teachers' ratings were low to moderate. Correlations between social skills subdomains and behavioural problems subdomains were low to high. Cronbach coefficients alpha were satisfactory for the two subdomains.
LeVasseur, Sandra A; Li, Dongmei
2013-01-01
Background The use of personal communication devices (such as basic cell phones, enhanced cell phones or smartphones, and tablet computers) in hospital units has risen dramatically in recent years. The use of these devices for personal and professional activities can be beneficial, but also has the potential to negatively affect patient care, as clinicians may become distracted by these devices. Objective No validated questionnaire examining the impact of the use of these devices on patient care exists; thus, we aim to develop and validate an online questionnaire for surveying the views of registered nurses with experience of working in hospitals regarding the impact of the use of personal communication devices on hospital units. Methods A 50-item, four-domain questionnaire on the views of registered nursing staff regarding the impact of personal communication devices on hospital units was developed based on a literature review and interviews with such nurses. A repeated measures pilot study was conducted to examine the psychometrics of a survey questionnaire and the feasibility of conducting a larger study. Psychometric testing of the questionnaire included examining internal consistency reliability and test-retest reliability in a sample of 50 registered nurses. Results The response rate for the repeated measures was 30%. Cronbach coefficient alpha was used to examine the internal consistency and reliability, and in three of the four question groups (utilization, impact, and opinions), the correlation was observed to be very high. This suggests that the questions were measuring a single underlying theme. The Cronbach alpha value for the questions in the performance group, describing the use of personal communication devices while working, was lower than those for the other question groups. These values may be an indication that the assumptions underlying the Cronbach alpha calculation may have been violated for this group of questions. A Spearman rho correlation was used to determine the test-retest reliability. There was a strong test-retest reliability between the two tests for the majority of the questions. The average test-retest percent of agreement for the Likert scale responses was 74% (range 43-100%). Accounting for responses within the 1 SD range on the Likert scale increased the agreement to 96% (range 87-100%). Missing data were in the range of 0 to 7%. Conclusions The psychometrics of the questionnaire showed good to fair levels of internal consistency and test-retest reliability. The pilot study demonstrated that our questionnaire may be useful in exploring registered nurses’ perceptions of the impact of personal electronic devices on hospital units in a larger study. PMID:24280660
[Reliability and Validity of the Scale for Homophobia in Medicine Students].
Campo-Arias, Adalberto; Lafaurie, María Mercedes; Gaitán-Duarte, Hernando G
2012-12-01
There are several scales to quantify homophobia in different populations. However, the reliability and validity of these instruments among Colombian students are unknown. Consequently, this work is intended to assess reliability (inner consistency) as well as the validity of the Scale for Homophobia in Medicine students from a private university in Bogotá (Colombia). Methodological study with 199 Medicine students from 1st to 5th semester that filled out the Homophobia Scale form, the general welfare questionnaire, the Attitude Towards Gays and Lesbians Scale (ATGL), WHO-5 (divergent validity) and the Francis Scale of Attitude Toward Christianity (nomologic validity). Pearson's correlations were computed, the Cronbach's alfa coefficient, the omega coefficient (construct's reliability) and confirmatory factorial analysis. The Scale for Homophobia showed an alpha Cronbach coefficient of 0,785, an omega coefficient of 0,790 and a Pearson correlation with the ATGL of 0,844; with WHO-5, -0,059; and a Francis Scale of Attitude Toward Christianity, 0,187. The Scale toward Homophobia exhibited a relevant factor of 44,7% of the total variance. The Scale for Homophobia showed acceptable reliability and validity. New studies should investigate the stability of the scale and the nomologic validity regarding other constructs. Copyright © 2012 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.
Rosales, Roberto S; Martin-Hidalgo, Yolanda; Reboso-Morales, Luis; Atroshi, Isam
2016-03-03
The purpose of this study was to assess the reliability and construct validity of the Spanish version of the 6-item carpal tunnel syndrome (CTS) symptoms scale (CTS-6). In this cross-sectional study 40 patients diagnosed with CTS based on clinical and neurophysiologic criteria, completed the standard Spanish versions of the CTS-6 and the disabilities of the arm, shoulder and hand (QuickDASH) scales on two occasions with a 1-week interval. Internal-consistency reliability was assessed with the Cronbach alpha coefficient and test-retest reliability with the intraclass correlation coefficient, two way random effect model and absolute agreement definition (ICC2,1). Cross-sectional precision was analyzed with the Standard Error of the Measurement (SEM). Longitudinal precision for test-retest reliability coefficient was assessed with the Standard Error of the Measurement difference (SEMdiff) and the Minimal Detectable Change at 95 % confidence level (MDC95). For assessing construct validity it was hypothesized that the CTS-6 would have a strong positive correlation with the QuickDASH, analyzed with the Pearson correlation coefficient (r). The standard Spanish version of the CTS-6 presented a Cronbach alpha of 0.81 with a SEM of 0.3. Test-retest reliability showed an ICC of 0.85 with a SRMdiff of 0.36 and a MDC95 of 0.7. The correlation between CTS-6 and the QuickDASH was concordant with the a priori formulated construct hypothesis (r 0.69) CONCLUSIONS: The standard Spanish version of the 6-item CTS symptoms scale showed good internal consistency, test-retest reliability and construct validity for outcomes assessment in CTS. The CTS-6 will be useful to clinicians and researchers in Spanish speaking parts of the world. The use of standardized outcome measures across countries also will facilitate comparison of research results in carpal tunnel syndrome.
Karataş, Tuğba; Özen, Şükrü; Kutlutürkan, Sevinç
2017-01-01
Objective: The main aim of this study was to investigate the factor structure and psychometric properties of the Brief Illness Perception Questionnaire (BIPQ) in Turkish cancer patients. Methods: This methodological study involved 135 cancer patients. Statistical methods included confirmatory or exploratory factor analysis and Cronbach alpha coefficients for internal consistency. Results: The values of fit indices are within the acceptable range. The alpha coefficients for emotional illness representations, cognitive illness representations, and total scale are 0.83, 0.80, and 0.85, respectively. Conclusions: The results confirm the two-factor structure of the Turkish BIPQ and demonstrate its reliability and validity. PMID:28217734
The Validity and Reliability of the Persian Version Test of Mobile Phone Dependency (TMD).
Mohammadi, Mohammadreza; Alavi, Seyyed Salman; Farokhzad, Pegah; Jannatifard, Fereshteh; Mohammadi Kalhori, Soroush; Sepahbodi, Ghazal; Baba Reisi, Mohammad; Sajedi, Sanaz; Farshchi, Mojtaba; Khoda Karami, Rasul; Hatami Kasvaee, Vahid; Sepasi, Neda; Alavi, Samaneh Sadat
2015-09-01
Despite the fact that the mobile phone has become a pervasive technology of our time, little research has been done on mobile dependency. A valid and reliable assessment instrument corresponding to the Persian culture is essential. This study aimed to describe the construction and validation of the Persian version of TMD (Test of Mobile phone Dependency) to assess the addictive use of mobile phone. This was a cross-sectional study, for which data were collected from 350 students who were studying at Tehran universities. Sampling method was quota sampling. The participants anonymously completed the demographic questionnaire, and CPDQ as a valid questionnaire and gold standard. Finally, clinical interview [based on DSM-IV-TR] was performed. To analyze the data, concurrent validity, factor analysis, internal consistency (Cronbachα), split half; test-retest and ROC Curve by SPSS18 Software were used. As a result of the reliability analysis and factor analysis by principal component and Varimax rotation, three factors ("salient", "preoccupation" and "Spend a lot of time and money") for both male and female participants were extracted. Internal consistency (Cronbach's alpha) of the TMD was .92 (Cronbach alpha of the factors is .88, .82, and .84, respectively). The test-retest correlation of the TMD was .56.The best cut off point for this questionnaire (TMD) is 38. The TMD proved to have an acceptable internal consistency with adequate factor models to assess the extent of problems caused by the "misuse" of the mobile phone in the Iranian society. Therefore, it can be concluded that the Persian version of the test was reliable and valid; however, further analysis is needed..
The Validity and Reliability of the Persian Version Test of Mobile Phone Dependency (TMD)
Mohammadi, Mohammadreza; Alavi, Seyyed Salman; Farokhzad, Pegah; Jannatifard, Fereshteh; Mohammadi Kalhori, Soroush; Sepahbodi, Ghazal; Baba Reisi, Mohammad; Sajedi, Sanaz; Farshchi, Mojtaba; Khoda Karami, Rasul; Hatami Kasvaee, Vahid; Sepasi, Neda; Alavi, Samaneh Sadat
2015-01-01
Objective: Despite the fact that the mobile phone has become a pervasive technology of our time, little research has been done on mobile dependency. A valid and reliable assessment instrument corresponding to the Persian culture is essential. This study aimed to describe the construction and validation of the Persian version of TMD (Test of Mobile phone Dependency) to assess the addictive use of mobile phone. Methods: This was a cross-sectional study, for which data were collected from 350 students who were studying at Tehran universities. Sampling method was quota sampling. The participants anonymously completed the demographic questionnaire, and CPDQ as a valid questionnaire and gold standard. Finally, clinical interview [based on DSM-IV-TR] was performed. To analyze the data, concurrent validity, factor analysis, internal consistency (Cronbachα), split half; test-retest and ROC Curve by SPSS18 Software were used. Results: As a result of the reliability analysis and factor analysis by principal component and Varimax rotation, three factors (“salient”, “preoccupation” and “Spend a lot of time and money”) for both male and female participants were extracted. Internal consistency (Cronbach's alpha) of the TMD was .92 (Cronbach alpha of the factors is .88, .82, and .84, respectively). The test-retest correlation of the TMD was .56.The best cut off point for this questionnaire (TMD) is 38. Conclusion: The TMD proved to have an acceptable internal consistency with adequate factor models to assess the extent of problems caused by the "misuse" of the mobile phone in the Iranian society. Therefore, it can be concluded that the Persian version of the test was reliable and valid; however, further analysis is needed. PMID:27006671
Vasconcellos, Ilmeire Ramos Rosembach de; Griep, Rosane Härter; Portela, Luciana; Alves, Márcia Guimarães de Mello; Rotenberg, Lúcia
2016-06-27
To describe the steps in the transcultural adaptation of the scale in the Effort-reward imbalance model to household and family work to the Brazilian context. We performed the translation, back-translation, and initial psychometric evaluation of the questionnaire that comprised three dimensions: (i) effort (eight items, emphasizing quantitative workload), (ii) reward (11 items that seek to capture the intrinsic value of family and household work, societal esteem, recognition from the spouse/partner, and affection from the children), and (iii) overcommitment (four items related to intrinsic effort). The scale was included in a sectional study conducted with 1,045 nursing workers. A subsample of 222 subjects answered the questionnaire for a second time, seven to 15 days thereafter. The data were collected between October 2012 and May 2013. The internal consistency of the scale was evaluated using Cronbach's alpha and test-retest reliability analysis, square weighted kappa, prevalence and bias adjusted Kappa, and intraclass correlation coefficient. Prevalence and bias-adjusted Kappa (ka) of the scale dimensions ranged from 0.80-0.83 for overcommitment, 0.78-0.90 for effort, and 0.76-0.93 for reward. In most dimensions, the values of minimum and maximum scores, average, standard deviation, and Cronbach's alpha were similar in test and retest scores. Only on societal esteem subdimension (reward) was there little variation in standard deviation (test score of 2.24 and retest score of 3.36) and in Cronbach's alpha coefficient (test score of 0.38 and retest score of 0.59). The Brazilian version of the scale was found to have proper reliability indices regarding time stability, which suggests adapting it to be used in population with characteristics that are similar to the one in this study. Descrever as etapas da adaptação transcultural da escala do Effort-reward imbalance model to household and family work para o contexto brasileiro. Efetuou-se a tradução, retrotradução e avaliação psicométrica inicial do instrumento composto por três dimensões: (i) esforço (oito itens, enfatizando a carga quantitativa de trabalho), (ii) recompensa (11 itens que buscam captar o valor intrínseco da família e do trabalho doméstico, a estima social, o reconhecimento do cônjuge ou companheiro e a afeição dos filhos) e (iii) o excesso de comprometimento (quatro itens relacionados ao esforço intrínseco). A escala foi incluída em um estudo seccional aplicado em 1.045 trabalhadoras de enfermagem. Uma subamostra de 222 participantes respondeu ao questionário pela segunda vez, com intervalo de sete a 15 dias. Os dados foram coletados entre outubro de 2012 e maio de 2013. A consistência interna da escala foi avaliada pelo coeficiente de alpha de Cronbach e a confiabilidade teste-reteste, pelo índice kappa ponderado quadrático, pelo kappa ajustado pela prevalência e pelo coeficiente de correlação intraclasse. A confiabilidade ajustada pela prevalência (ka) das dimensões da escala variou de 0,80-0,83 para o excesso de comprometimento, 0,78-0,90 para o esforço e 0,76-0,93 para a recompensa. Na maioria das dimensões, os valores do escore mínimo e máximo, média, desvio-padrão e alpha de Cronbach no teste e no reteste foram semelhantes. Somente na subdimensão estima social (recompensa) houve pequena variação no desvio padrão (2,24 no teste e 3,36 no reteste) e no coeficiente de alpha de Cronbach (0,38 no teste e 0,59 no reteste). A versão brasileira da escala apresentou índices adequados de fidedignidade quanto à estabilidade temporal, o que sugere a adequação da escala para uso em populações com características semelhantes à do estudo.
Psychometric goodness of the Mini Sleep Questionnaire.
Natale, Vincenzo; Fabbri, Marco; Tonetti, Lorenzo; Martoni, Monica
2014-07-01
The current study was conducted to evaluate the psychometric properties and analyze the convergent validity of the Italian version of the Mini Sleep Questionnaire (MSQ). In addition, it was aimed to put forward cut-off values to be used in screening protocols. The MSQ was administered to 1830 participants (age range 18-87 years), of whom 1208 also completed the Sleep Disorder Questionnaire (age range 18-87 years). A subgroup of 187 (age range 18-71 years) participants was randomly chosen to test the test-retest reliability. A complete psychometric evaluation was performed on the MSQ. To study the validity of the tool, the Sleep Disorder Questionnaire was used as an external criterion to validate the MSQ. Using the Youden index, we calculated the cut-off values that performed best. Finally, we created receiver-operator curves to test the accuracy of each cut-off value identified. For the MSQ, Cronbach's alpha score was 0.77 while homogeneity was 0.26. Factorial analyses confirmed the presence of two dimensions: sleep (Cronbach's alpha 0.75; homogeneity 0.37) and wake (Cronbach's alpha 0.75; homogeneity 0.44). For each dimension, a cut-off value was identified (>16 and >14, respectively). Both cut-off values obtained an area under the curve higher than 0.80. Psychometric evaluation of the MSQ was satisfactory. The cut-off values analyzed in the present study showed good performance. On the whole, the results of this study suggest that the MSQ can be a useful screening tool. © 2014 The Authors. Psychiatry and Clinical Neurosciences © 2014 Japanese Society of Psychiatry and Neurology.
Das, Saurbhi; Aggarwal, Anju; Roy, Shambhawi; Kumar, Pankaj
2017-01-01
Quality of life (QOL) in children with cerebral palsy (CP) needs to be measure by CP-specific questionnaire. CP-QOL questionnaire is being used for this purpose. The aim is to determine the QOL in Indian children with CP using CP-QOL questionnaire and to correlate QOL scores with demographic details of the patient. Subjects were parents of 50 children (4-12 years) attending child development center of Guru Teg Bahadur Hospital were enrolled. The parent-proxy version of the CP-QOL questionnaire translated into Hindi was administered by one author. Scoring and analysis were performed as per specified method. Cronbach's alpha was calculated for each domain for validation. Effect of clinical and demographic profile on QOL was analyzed. CP-QOL questionnaire was administered to 50 parents of CP children (32 males, 18 females). The overall QOL score of the children studied was computed to be 38.29 ± 5.2. Age and maternal education had a significant bearing on the QOL of the children ( P < 0.05). Type of CP, gender, and epilepsy did not affect the QOL significantly ( P > 0.05). Good internal consistency and reliability were found in the domains of social well-being and acceptance, functioning, participation, and physical health (Cronbach's alpha >0.7). Access to services, pain, and impact of disability and family health showed a weak correlation with Cronbach's alpha <0.7. QOL in children with CP was compromised. The CP-QOL questionnaire can be used to measure QOL in Indian children with CP.
Flamarique, I; Santosh, P; Zuddas, A; Arango, C; Purper-Ouakil, D; Hoekstra, P J; Coghill, D; Schulze, U; Dittmann, R W; Buitelaar, J K; Lievesley, K; Frongia, R; Llorente, C; Méndez, I; Sala, R; Fiori, F; Castro-Fornieles, J
2016-12-13
To create a self-reported, internet-based questionnaire for the assessment of suicide risk in children and adolescents. As part of the EU project 'Suicidality: Treatment Occurring in Paediatrics' (STOP project), we developed web-based Patient Reported Outcome Measures (PROMs) for children and adolescents and for proxy reports by parents and clinicians in order to assess suicidality. Based on a literature review, expert panels and focus groups of patients, we developed the items of the STOP Suicidality Assessment Scale (STOP-SAS) in Spanish and English, translated it into four more languages, and optimized it for web-based presentation using the HealthTracker TM platform. Of the total 19 questions developed for the STOP-SAS, four questions that assess low-level suicidality were identified as screening questions (three of them for use with children, and all four for use with adolescents, parents and clinicians). A total of 395 adolescents, 110 children, 637 parents and 716 clinicians completed the questionnaire using the HealthTracker TM , allowing us to evaluate the internal consistency and convergent validity of the STOP-SAS with the clinician-rated Columbia Suicide Severity Rating Scale (C-SSRS). Validity was also assessed with the receiver operating characteristic (ROC) area of the STOP-SAS with the C-SSRS. The STOP-SAS comprises 19 items in its adolescent, parent, and clinician versions, and 14 items in its children's version. Good internal consistency was found for adolescents (Cronbach's alpha: 0.965), children (Cronbach's alpha: 0.922), parents (Cronbach's alpha: 0.951) and clinicians (Cronbach's alpha: 0.955) versions. A strong correlation was found between the STOP-SAS and the C-SSRS for adolescents (r:0.670), parents (r:0.548), clinicians (r:0.863) and children (r:0.654). The ROC area was good for clinicians' (0.917), adolescents' (0.834) and parents' (0.756) versions but only fair (0.683) for children's version. The STOP-SAS is a comprehensive, web-based PROM developed on the HealthTracker TM platform, and co-designed for use by adolescents, children, parents and clinicians. It allows the evaluation of aspects of suicidality and shows good reliability and validity.
Laleh, Leila; Latifi, Sahar; Koushki, Davood; Matin, Marzieh; Javidan, Abbas Norouzi; Yekaninejad, Mir Saeed
2015-01-01
Patients with spinal cord injury (SCI) deal with various restrictive factors regarding their clothing, such as disability and difficulty with access to shopping centers. We designed a questionnaire to assess attention to clothing and impact of its restrictive factors among Iranian patients with SCI (ACIRF-SCI). The ACIRF-SCI has 5 domains: functional, medical, attitude, aesthetic, and emotional. The first 3 domains reflect the impact of restrictive factors (factors that restrict attention to clothing), and the last 2 domains reflect attention to clothing and fashion. Functional restrictive factors include disability and dependence. Medical restrictive factors include existence of specific medical conditions that interfere with clothing choice. Construct validity was assessed by factorial analysis, and reliability was expressed by Cronbach's alpha. A total of 100 patients (75 men and 25 women) entered this study. Patients with a lower injury level had a higher total score (P < .0001), and similarly, patients with paraplegia had higher scores than those with tetraplegia (P < .0001), which illustrates an admissible discriminant validity. Postinjury duration was positively associated with total scores (r = 0.21, P = .04). Construct validity was 0.97, and Cronbach's alpha was 0.61. Iranian patients with SCI who have greater ability and independence experience a lower impact of restrictive factors related to clothing. The ACIRF-SCI reveals that this assumption is statistically significant, which shows its admissible discriminant validity. The measured construct validity (0.97) and reliability (internal consistency expressed by alpha = 0.61) are acceptable.
Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish
Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan
2015-01-01
Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.
Addison, Clifton C.; Campbell-Jenkins, Brenda W.; Sarpong, Daniel F.; Kibler, Jeffery; Singh, Madhu; Dubbert, Patricia; Wilson, Gregory; Payne, Thomas; Taylor, Herman
2007-01-01
This study sought to establish the psychometric properties of a Coping Strategies Inventory Short Form (CSI-SF) by examining coping skills in the Jackson Heart Study cohort. We used exploratory and confirmatory factor analysis, Pearson’s correlation, and Cronbach Alpha to examine reliability and validity in the CSI-SF that solicited responses from 5302 African American men and women between the ages of 35 and 84. One item was dropped from the 16-item CSI-SF, making it a 15-item survey. No significant effects were found for age and gender, strengthening the generalizability of the CSI-SF. The internal consistency reliability analysis revealed reliability between alpha = 0.58–0.72 for all of the scales, and all of the fit indices used to examine the CSI-SF provided support for its use as an adequate measure of coping. This study provides empirical support for utilizing this instrument in future efforts to understand the role of coping in moderating health outcomes. PMID:18180539
Development and validation of the stigma scale for epilepsy in Turkey.
Baybaş, Sevim; Yıldırım, Zerrin; Ertem, Devrimsel Harika; Dirican, Ayten; Dirican, Ahmet
2017-02-01
Epilepsy is a chronic disease with an increased risk of stigma. The aim of this study was to investigate the efficacy of a scale developed by the authors to determine the level of stigma in Turkish patients with epilepsy and their relatives. In this pilot study, two scales were developed, one consisting of 32 questions for the patients and one of 20 questions for the patients' relatives. Initially, a total of 30 patients with epilepsy and 30 relatives of the patients were included. The Cronbach's alpha coefficient was calculated in a reliability analysis of validity applying the scales to 302 patients and 201 relatives of the patients. The Pearson correlation coefficient was used for the reliability analysis of the test-retest. The t-test was used in paired series, and factor analysis was conducted. The correlation between the clinical and demographical data and the stigma scores was evaluated. The scales were applied to participants twice under the same conditions in one-week interval. In the test-retest analysis, the internal consistency of the scales was high and reliable. In the analysis of the patients, the Cronbach's alpha value of the scale was found to be 0.915. In the factor analysis, the questions were grouped into five factors including social isolation, discrimination, insufficiency, false beliefs, and stigma resistance. The factors with the highest contribution to the stigma level were social isolation and discrimination. In the stigma scores, a significant correlation was found between the age of the patient, frequency of seizures, education status, level of income, and the amount of antiepileptic drugs used. In the analysis of the patients' relatives, the Cronbach's alpha value of the scale was found to be 0.892. In the factor analysis, the questions were classified as discrimination, prejudgments, and false beliefs. The factor which most contributed to the stigma level was discrimination. A significant correlation was found in the stigma scores between sex, education status, marital status, and income distribution. According to our study results, it is clearly seen that both patients and their relatives suffer from epilepsy-associated stigma. Patients with epilepsy and their relatives are faced with discrimination in society, resulting in social isolation. We, therefore, believe that both patients and their relatives should be informed in detail about discrimination to overcome this challenge. Copyright © 2016 Elsevier Inc. All rights reserved.
Amaral, Anna Beatriz C N; Rider, Elizabeth A; Lajolo, Paula P; Tone, Luiz G; Pinto, Rogerio M C; Lajolo, Marisa P; Calhoun, Aaron W
2016-12-11
The goal of this study was to translate, adapt and validate the items of the Gap-Kalamazoo Communication Skills Assessment Form for use in the Brazilian cultural setting. The Gap-Kalamazoo Communication Skills Assessment Form was translated into Portuguese by two independent bilingual Brazilian translators and was reconciled by a third bilingual healthcare professional. The translated text was then assessed for content using a modified Delphi technique and adjusted as needed to assure content validity. A total of nine phrases in the completed tool were adjusted. The final tool was then used to assess videotaped simulations as a means of validation. Response process was assessed using exploratory factor analysis and internal structure was assessed via Cronbach's Alpha (internal consistency) and Intraclass Correlation (test-retest reliability and inter-rater reliability). One hundred and four (104) videotaped communication skills simulations were assessed by 38 subjects (6 staff physicians, 4 faculty physicians, 8 resident physicians, 4 professional actors with experience in simulation, and 16 other allied healthcare professionals). Measures of Internal consistency (Cronbach's alpha = 0.818) and test-retest reliability (intra-class correlation coefficient = 0.942) were high. Exploratory factor analysis confirmed the uni-dimensionality of the instrument. Our results support the validity and reliability of the Brazilian Gap-Kalamazoo Communication Skills Assessment Form when used among Brazilian medical residents. The Brazilian version of Gap-Kalamazoo Communication Skills Assessment Form was found to be adequate both in the linguistic and technical aspects. The use of this instrument in Brazilian medical education can enhance the assessment of physician-patient-team relationships on an ongoing basis.
Measuring teamwork and conflict among emergency medical technician personnel.
Patterson, P Daniel; Weaver, Matthew D; Weaver, Sallie J; Rosen, Michael A; Todorova, Gergana; Weingart, Laurie R; Krackhardt, David; Lave, Judith R; Arnold, Robert M; Yealy, Donald M; Salas, Eduardo
2012-01-01
We sought to develop a reliable and valid tool for measuring teamwork among emergency medical technician (EMT) partnerships. We adapted existing scales and developed new items to measure components of teamwork. After recruiting a convenience sample of 39 agencies, we tested a 122-item draft survey tool (EMT-TEAMWORK). We performed a series of exploratory factor analyses (EFAs) and confirmatory factor analysis (CFA) to test reliability and construct validity, describing variation in domain and global scores using descriptive statistics. We received 687 completed surveys. The EFAs identified a nine-factor solution. We labeled these factors 1) Team Orientation, 2) Team Structure & Leadership, 3) Partner Communication, Team Support, & Monitoring, 4) Partner Trust and Shared Mental Models, 5) Partner Adaptability & Back-Up Behavior, 6) Process Conflict, 7) Strong Task Conflict, 8) Mild Task Conflict, and 9) Interpersonal Conflict. We tested a short-form (30-item SF) and long-form (45-item LF) version. The CFAs determined that both the SF and the LF possess positive psychometric properties of reliability and construct validity. The EMT-TEAMWORK-SF has positive internal consistency properties, with a mean Cronbach's alpha coefficient ≥0.70 across all nine factors (mean = 0.84; minimum = 0.78, maximum = 0.94). The mean Cronbach's alpha coefficient for the EMT-TEAMWORK-LF was 0.87 (minimum = 0.79, maximum = 0.94). There was wide variation in weighted scores across all nine factors and the global score for the SF and LF. Mean scores were lowest for the Team Orientation factor (48.1, standard deviation [SD] 21.5, SF; 49.3, SD 19.8, LF) and highest (more positive) for the Interpersonal Conflict factor (87.7, SD 18.1, for both SF and LF). We developed a reliable and valid survey to evaluate teamwork between EMT partners.
The Self-Stigma of Depression Scale: Translation and Validation of the Arabic Version
Darraj, Hussain Ahmed; Mahfouz, Mohamed Salih; Al Sanosi, Rashad Mohamed; Badedi, Mohammed; Sabai, Abdullah
2017-01-01
Background: Self-stigma may feature strongly and be detrimental for people with depression, but the understanding of its nature and prevalence is limited by the lack of psychometrically validated measures. This study is aimed to validate the Arabic version self-stigma of depression scale (SSDS) among adolescents. Materials and Methods: A cross-sectional study involved 100 adolescents randomly selected. The analyses include face validation, factor analysis, and reliability testing. A test–retest was conducted within a 2-week interval. Results: The mean score for self-stigma of depression among study participants was 68.9 (Standard deviation = 8.76) median equal to 71 and range was 47. Descriptive analysis showed that the percentage of those who scored below the mean score (41.7%) is shown less than those who scored above the mean score (58.3%). Preliminary construct validation analysis confirmed that factor analysis was appropriate for the Arabic-translated version of the SSDS. Furthermore, the factor analysis showed similar factor loadings to the original English version. The total internal consistency of the translated version, which was measured by Cronbach's alphas ranged from 0.70 to 0.77 for the four subscales and 0.84 for the total scale. Test–retest reliability was assessed in 65 respondents after 2 weeks. Cronbach's alphas ranged from 0.70 to 0.77 for the four subscales and 0.84 for the total scale. Conclusions: Face validity, construct validity, and reliability analysis were found satisfactory for the Arabic-translated version of the SSDS. The Arabic-translated version of the SSDS was found valid and reliable to be used in future studies, with comparable properties to the original version and to previous studies. PMID:28149090
Finotto, Sergio; Gradellini, Cinzia; Bandini, Stefania; Burrai, Francesco; Lucchi Casadei, Sandra; Villani, Carolina; Vincenzi, Simone; Mecugni, Daniela
2017-01-01
To evaluate the psychometric characteristics of the Scheda di Valutazione delle Attività di Tirocinio (SVAT). The degree courses in Nursing of the University of Modena and Reggio Emilia, site of Reggio Emilia, the University of Bologna Formative Section BO1, Imola and training center of Cesena, the University of Ferrara training centers of Ferrara and Codigoro were all enrolled in the research. For the content validation the reactive Delphi method was chosen. The panel of experts expressed a qualitative-intuitive judgment on the adequacy of language and on the stimulus material (SVAT). For internal consistency Cronbach's alpha was calculated the. The test-retest method was used for the reliability of stability. all indicators of the SVAT have achieved a degree of consensus not less than 80% demonstrating its content validity. The face validity is demonstrated by an average score equal to or greater than 7 obtained by all indicators. The reliability of internal consistency of the SVAT was appraised by Cronbach's alpha that was 0.987 for the entire instrument. The reliability of the stability has been calculated through the correlation's coefficient expressed by Pearson's r that was 0.983 (p = 1.3E-198). in Italy there is no a "gold standard" tool to evaluate the clinical performance of nursing students during and at the end of their clinical training. The SVAT proves to be a valuable and reliable tool it furthermore could stimulate the discussion and the debate among educators and nurses, so that also in our country, it may be possible develop and refine tools that support the evaluation of clinical skills of nursing students.
Soltani, Esmail; Bahrainian, Seyed Abdolmajid; Masjedi Arani, Abbas; Farhoudian, Ali; Gachkar, Latif
2016-06-01
Social anxiety disorder is often related to specific impairment or distress in different areas of life, including occupational, social and family settings. The purpose of the present study was to examine the psychometric properties of the persian version of the social anxiety-acceptance and action questionnaire (SA-AAQ) in university students. In this descriptive cross-sectional study, 324 students from Shahid Beheshti University of Medical Sciences participated via the cluster sampling method during year 2015. Factor analysis by the principle component analysis method, internal consistency analysis, and convergent and divergent validity were conducted to examine the validity of the SA-AAQ. To calculate the reliability of the SA-AAQ, Cronbach's alpha and test-retest reliability were used. The results from factor analysis by principle component analysis method yielded three factors that were named acceptance, action and non-judging of experience. The three-factor solution explained 51.82% of the variance. Evidence for the internal consistency of SA-AAQ was obtained via calculating correlations between SA-AAQ and its subscales. Support for convergent and discriminant validity of the SA-AAQ via its correlations with the acceptance and action questionnaire - II, social interaction anxiety scale, cognitive fusion questionnaire, believability of anxious feelings and thoughts questionnaire, valued living questionnaire and WHOQOL- BREF was obtained. The reliability of the SA-AAQ via calculating Cronbach's alpha and test-retest coefficients yielded values of 0.84 and 0.84, respectively. The Iranian version of the SA-AAQ has acceptable levels of psychometric properties in university students. The SA-AAQ is a valid and reliable measure to be utilized in research investigations and therapeutic interventions.
Nair, Rahul; Tsakos, Georgios; Yee Ting Fai, Robert
2016-12-01
To cross-culturally adapt the oral impacts on daily performance (OIDP) and assess its reliability and validity on Chinese-speaking community dwelling elderly Singaporeans. There are no previous reports of valid oral health-related quality of life instruments for elderly Singaporeans or perceived conditions associated with impacts reported in OIDP among the Singaporean elders. The OIDP was translated from English to Chinese and then back translated. The OIDP questionnaire along with questions related to overall quality of life and self-rated dental health was administered to 202 Chinese-speaking elderly Singaporeans by trained interviewers, and it was repeated after 1 month. Test-retest reliability was assessed using intraclass correlation coefficient; internal consistency was established using Cronbach's alpha, and construct validity using correlation coefficients with self-reported oral health-related and global quality of life measures. In addition, Kruskal-Wallis tests assessed differences in the OIDP score between different subjective health and global quality of life groups. The median age of participants was 75 years. About 19% reported oral impacts and difficulty eating was the most prevalent oral impact. Internal consistency was good with a Cronbach's alpha of 0.75, and the intraclass correlation coefficient was 0.75 (0.67-0.81). OIDP was significantly correlated with all measures of self-reported oral health and global ratings of quality of life, with correlation coefficients ranging between 0.15 and 0.52. Groups with worse perceptions about their health and quality of life had significantly higher OIDP scores. The OIDP showed successful reliability and validity for its use among Chinese-speaking older Singaporeans. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.
Azzam, Michael G; Lenarz, Christopher J; Farrow, Lutul D; Israel, Heidi A; Kieffer, David A; Kaar, Scott G
2011-08-01
To validate the use of the clock face reference as a reliable means of communicating femoral intercondylar notch position. A single red mark was made on ten identical left Sawbones femurs in the intercondylar notch at variable locations. Ten surgeons, who routinely perform ACL reconstructions, were presented the femurs in random order and asked to state the position of the mark to the nearest 30-min interval. Responses were recorded and then repeated 3 weeks later. The same 10 surgeons were presented with 30 actual arthroscopic photographs of the intercondylar notch, performed at 90° of knee flexion, with a probe pointing at various locations (10 knees; 3 photographs/knee) along the lateral aspect of the notch. The results were then analyzed with an ICC, Cronbach's alpha test, and descriptive statistics. For the Sawbones, the ICC was 0.996 while individual physician's Cronbach's alpha test ranged from 0.954 to 0.999, indicating a very high interobserver and intraobserver reliability. The mean range of responses among the 10 surgeons was 1.6 h, SD 0.6. For the photographs, the ICC was also high at 0.997. There was a mean range of 1.1 h, SD 0.4, among surgeons. The clock face method is commonly utilized for both placement of the femoral tunnel during ACL reconstruction as well as describing the location of the ACL femoral tunnel between communicating surgeons. Despite a high statistical interobserver correlation, there is significant range among different surgeons' responses. The present study questions the reliability of the clock face method for use between surgeons as a stand alone tool. Other methods also utilizing anatomic landmarks may be more accurate for describing intercondylar notch anatomy. III.
Quality-of-life survey for patients diagnosed with nonmuscle-invasive bladder cancer.
Abáigar-Pedraza, I; Megías-Garrigós, J; Sánchez-Payá, J
2016-05-01
To determine the reliability and validity of a quality-of-life survey for patients with nonmuscle-invasive bladder cancer. A total of 180 patients were included in the study. We developed a survey with 21 questions grouped into 5 areas. The patients filled in this survey and the Functional Assessment of Cancer Therapy - Bladder Cancer (FACT-BL) survey. To assess reliability, we calculated Cronbach's alpha coefficient and the kappa index. To determine criterion validity, we studied the association between the scores obtained from our survey and those from the FACT-BL survey using the Pearson correlation coefficient. To determine the construct validity (factorial and discriminatory), we performed a factor analysis, comparing it with Student's t-test for the scores obtained according to the tumour characteristics of reduced quality of life (e.g., malignancies located at the trigone of the bladder). Cronbach's alpha reliability coefficient was .83, and the kappa index varied between .7 and 1. For the association study between the new survey and the FACT-BL survey, we measured an r=.82 for the overall score and between r=.68 (disease) and r=.97 (sex life) in the various measures. In the factor analysis, we measured a Kaiser-Meyer-Olkin index of .77 and performed the Barlett test (P<.001). The comparison between the scores, in the presence or absence of certain tumour characteristics, has shown a reduced quality of life when those characteristics are present, which was statistically significant (P<.05) in the majority of cases. Our survey to measure the quality of life of patients with nonmuscle-invasive bladder cancer is reliable and valid. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Cheung, Kenneth M C; Senkoylu, Alpaslan; Alanay, Ahmet; Genc, Yasemin; Lau, Sarah; Luk, Keith D
2007-05-01
Validation study to define validity and reliability of an adapted and translated questionnaire. Assessment of the concurrent validity and reliability of a Chinese version of SRS-22 outcome instrument. No valid health-related quality of life (HRQL) outcome instrument exists for patients with spinal deformity in Chinese. The modified SRS-22 questionnaire was proven to be an appropriate outcome instrument in English, and has already been translated and validated in several other languages. The English version of the SRS-22 questionnaire was adapted to Chinese according to the International Quality of Life Assessment Project guidelines. To assess reliability, 48 subjects with adolescent idiopathic scoliosis (mean age, 16.5 years) filled the questionnaire on 2 separate occasions (Group 1). To assess concurrent validity, 50 subjects (mean age, 21 years) filled in the same questionnaire and a previously validated Chinese version of the Short Form-36 (SF36) questionnaire (Group 2). Internal consistency, reproducibility and concurrent validity were determined with Cronbach's alpha coefficient, interclass correlation coefficient and Pearson correlation coefficient, respectively. Cronbach's alpha coefficient for the 4 major domains (function/activity, pain, self-image/appearance and mental health) were high. Intraclass correlation was also excellent for all domains. For concurrent validity, excellent correlation was found in 1 domain, good in 12 domains, moderate in 3 domains, and poor in 1 domain of the 17 relevant domains. Both cultural adaptation and linguistic translation are essential in any attempt to use a HRQL questionnaire across cultures. The Chinese version of the SRS-22 outcome instrument has satisfactory internal consistency and excellent reproducibility. It is ready for use in clinical studies on idiopathic scoliosis in Chinese-speaking societies.
Trippolini, Maurizio Alen; Janssen, Svenja; Hilfiker, Roger; Oesch, Peter
2018-06-01
Purpose To analyze the reliability and validity of a picture-based questionnaire, the Modified Spinal Function Sort (M-SFS). Methods Sixty-two injured workers with chronic musculoskeletal disorders (MSD) were recruited from two work rehabilitation centers. Internal consistency was assessed by Cronbach's alpha. Construct validity was tested based on four a priori hypotheses. Structural validity was measured with principal component analysis (PCA). Test-retest reliability and agreement was evaluated using intraclass correlation coefficient (ICC) and measurement error with the limits of agreement (LoA). Results Total score of the M-SFS was 54.4 (SD 16.4) and 56.1 (16.4) for test and retest, respectively. Item distribution showed no ceiling effects. Cronbach's alpha was 0.94 and 0.95 for test and retest, respectively. PCA showed the presence of four components explaining a total of 74% of the variance. Item communalities were >0.6 in 17 out of 20 items. ICC was 0.90, LoA was ±12.6/16.2 points. The correlations between the M-SFS were 0.89 with the original SFS, 0.49 with the Pain Disability Index, -0.37 and -0.33 with the Numeric Rating Scale for actual pain, -0.52 for selfreported disability due to chronic low back pain, and 0.50, 0.56-0.59 with three distinct lifting tests. No a priori defined hypothesis for construct validity was rejected. Conclusions The M-SFS allows reliable and valid assessment of perceived self-efficacy for work-related tasks and can be recommended for use in patients with chronic MSD. Further research should investigate the proposed M-SFS score of <56 for its predictive validity for non-return to work.
[Development of patient-reported outcome scale for myasthenia gravis: a psychometric test].
Chen, Xin-lin; Liu, Feng-bin; Guo, Li; Liu, Xiao-bin
2010-02-01
To investigate the scientificity of patient-reported outcome (PRO) scale for myasthenia gravis (MG), which was used to evaluate the clinical effects of traditional Chinese and Western medicine treatment on MG patients. Psychometric performance of the MG-PRO scale was also expected to be evaluated in this study. A total of 100 MG patients and 100 healthy people were face-to-face interviewed by well-trained investigators, and the data of MG-PRO scale were collected. The classical theory test (CTT) and item response theory (IRT) methods were used to analyze the psychometric performance such as validity, reliability, person separation index (PSI) and differential item functioning (DIF) in the MG-PRO scale. The results of CTT analysis showed that the split-half reliabilities of the MG-PRO scale and each dimension were greater than 0.7. In the analysis of internal consistency of each dimension, the Cronbach's alpha was greater than 0.8. Each facet had greater correlation with its dimension than the other dimensions. Four principal components were extracted by exploratory factor analysis, which represented all dimensions of the scale, and the cumulative variance was 55.54%. The scores of each of the 8 facets between MG patients and healthy people were different (P<0.01). The results of IRT showed that the PSI of each model was greater than 0.8, and all items did not have uniform DIF and non-uniform DIF. The MG-PRO scale reflects the definition and connotation of quality of life and contains special issues of MG patients as well, and shows good reliability (split-half reliability, Cronbach's alpha), validity (content validity, construct validity, discriminate validity) from the results of CTT, and good psychometric performance from the results of IRT.
Pelegrino, Flávia M; Dantas, Rosana A S; Corbi, Inaiara S A; da Silva Carvalho, Ariana R; Schmidt, André; Pazin Filho, Antônio
2012-09-01
The aim of this study was to evaluate the internal reliability and validity of the Brazilian-Portuguese version of Duke Anticoagulation Satisfaction Scale (DASS) among cardiovascular patients. Oral anticoagulation is widely used to prevent and treat thromboembolic events in several conditions, especially in cardiovascular diseases; however, this therapy can induce dissatisfaction and reduce the quality of life. Methodological and cross-sectional research design. The cultural adaptation of the DASS included the translation and back-translation, discussions with healthcare professionals and patients to ensure conceptual equivalence, semantic evaluation and instrument pretest. The Brazilian-Portuguese version of the DASS was tested among subjects followed in a university hospital anticoagulation outpatient clinic. The psychometric properties were assessed by construct validity (convergent, known groups and dimensionality) and internal consistency/reliability (Cronbach's alpha). A total of 180 subjects under oral anticoagulation formed the baseline validation population. DASS total score and SF-36 domain correlations were moderate for General health (r=-0.47, p<0.01), Vitality (r=-0.44, p<0.01) and Mental health (r=-0.42, p<0.01) (convergent). Age and length on oral anticoagulation therapy (in years) were weakly correlated with total DASS score and most of the subscales, except Limitation (r=-0.375, p<0.01) (Known groups). The Cronbach's alpha coefficient was 0.79 for the total scale, and it ranged from 0.76 (hassles and burdens)-0.46 (psychological impact) among the domains, confirming the internal consistency reliability. The Brazilian-Portuguese version of the DASS has shown levels of reliability and validity comparable with the original English version. Healthcare practitioners and researchers need internationally validated measurement tools to compare outcomes of interventions in clinical management and research tools in oral anticoagulation therapy. © 2011 Blackwell Publishing Ltd.
Song, Rhayun; Oh, Hyunkyoung; Ahn, Sukhee; Moorhead, Sue
2018-02-01
The purpose of this study was to validate the Cardiac Health Behavior Scale for Korean adults (CHB-K) to determine its validity and reliability. Cardiovascular diseases (CVDs) are one of the most important chronic diseases due to their high prevalence and mortality rates. Patients with cardiovascular risks or diseases need to perform appropriate cardiac health behaviors that help to prevent the progression of the disease and improve their health status. This secondary analysis obtained data from two clinical trials of cardiac rehabilitation. Data from 298 patients with cardiovascular risks or diseases were analyzed for validation. Data analyses included correlation coefficients, t-tests, and exploratory and confirmatory factor analyses using SPSS (version WIN 22.0) and AMOS (version 20.0). The Self-Efficacy Scale was used to assess convergent validity, while reliability was assessed using Cronbach's alpha coefficients. Five main factors were verified: health responsibility, physical activity, diet habit (eating habit and food choice), stress management, and smoking cessation. A set of 21 items from the 25-item scale was verified after performing item analysis, factor analyses, and critical evaluation of the statistical results. The 21-item CHB-K (CHB-K21) exhibited acceptable validity, and the model of the CHB-K21 provided a good fit to the data. Most of the factors were found to be moderately correlated with SES scores (r=0.45-0.52, p<0.001). The CHB-K21 also demonstrated acceptable reliability (Cronbach's alpha=0.83). The CHB-K21 demonstrates strong validity and reliability. It can be used to assess cardiac health behaviors in Korean adults with cardiovascular risks or diseases. Copyright © 2017 Elsevier Inc. All rights reserved.
Lin, Chiu-Chu; Wu, Chia-Chen; Wu, Li-Min; Chen, Hsing-Mei; Chang, Shu-Chen
2013-04-01
This study aims to develop a valid and reliable chronic kidney disease self-management instrument (CKD-SM) for assessing early stage chronic kidney disease patients' self-management behaviours. Enhancing early stage chronic kidney disease patients' self-management plays a key role in delaying the progression of chronic kidney disease. Healthcare provider understanding of early stage chronic kidney disease patients' self-management behaviours can help develop effective interventions. A valid and reliable instrument for measuring chronic kidney disease patients' self-management behaviours is needed. A cross-sectional descriptive study collected data for principal components analysis with oblique rotation. Mandarin- or Taiwanese-speaking adults with chronic kidney disease (n=252) from two medical centres and one regional hospital in Southern Taiwan completed the CKD-SM. Construct validity was evaluated by exploratory factor analysis. Internal consistency and test-retest reliability were estimated by Cronbach's alpha and Pearson correlation coefficients. Four factors were extracted and labelled self-integration, problem-solving, seeking social support and adherence to recommended regimen. The four factors accounted for 60.51% of the total variance. Each factor showed acceptable internal reliability with Cronbach's alpha from 0.77-0.92. The test-retest correlations for the CKD-SM was 0.72. The psychometric quality of the CKD-SM instrument was satisfactory. Research to conduct a confirmatory factor analysis to further validate this new instrument's construct validity is recommended. The CKD-SM instrument is useful for clinicians who wish to identify the problems with self-management among chronic kidney disease patients early. Self-management assessment will be helpful to develop intervention tailored to the needs of the chronic kidney disease population. © 2013 Blackwell Publishing Ltd.
Gunaydin, Gurkan; Citaker, Seyit; Meray, Jale; Cobanoglu, Gamze; Gunaydin, Ozge Ece; Hazar Kanik, Zeynep
2016-11-01
Validation of a self-report questionnaire. The purpose of this study was to investigate adaptation, validity, and reliability of the Turkish version of the Bournemouth Questionnaire. Low back pain is one of the most frequent disorders leading to activity limitation. This pain affects most of people in their lives. The most important point to evaluate patient's functional abilities and to decide a successful therapy procedure is to manage the assessment questionnaires precisely. One hundred ten patients with chronic low back pain were included in present study. To assess reliability, test-retest and internal consistency analyses were applied. The results of test-retest analysis were assessed by using Intraclass Correlation Coefficient method (95% confidence interval). For internal consistency, Cronbach alpha value was calculated. Validity of the questionnaire was assessed in terms of construct validity. For construct validity, factor analysis and convergent validity were tested. For convergent validity, total points of the Bournemouth Questionnaire were assessed with the total points of Quebec Back Pain Disability Scale and Roland Morris Disability Questionnaire by using Pearson correlation coefficient analysis. Cronbach alpha value was found 0.914, showing that this questionnaire has high internal consistency. The results of test-retest analysis were varying between 0.851 and 0.927, which shows that test-retest results are highly correlated. Factor analysis test indicated that this questionnaire had one factor. Pearson correlation coefficient of the Bournemouth Questionnaire with Roland Morris Disability Questionnaire was calculated 0.703 and it was found with Quebec Back Pain Disability Scale is 0.659. These results showed that the Bournemouth Questionnaire is very good correlated with Roland Morris Disability Questionnaire and Quebec Back Pain Disability Scale. The Turkish version of the Bournemouth Questionnaire is valid and reliable. 3.
Abanto, Jenny; Albites, Ursula; Bönecker, Marcelo; Paiva, Saul M; Castillo, Jorge L; Aguilar-Gálvez, Denisse
2015-12-01
The lack of a Family Impact Scale (FIS) in Spanish language limits its use as an indicator in Spanish-speaking countries and precludes comparisons with data from other cultural and ethnic groups. The purpose of this study was therefore to adapt the FIS cross-culturally to the Peruvian Spanish language and assess its reliability and validity. In order to translate and adapt the FIS cross-culturally, it was answered by 60 parents in two pilot tests, after which it was tested on 200 parents of children aged 11 to 14 years who were clinically examined for dental caries experience and malocclusions. Internal consistency was assessed by Cronbach's alpha coefficient while repeat administration of the FIS on the same 200 parents enabled the test-retest reliability to be assessed via intraclass correlation coefficient (ICC). Construct and discriminant validity were based on associations of the FIS with global ratings of oral health and clinical groups, respectively. Mean (standard deviation) FIS total score was 5.20 (5.86). Internal consistency was confirmed by Cronbach's alpha 0.84. Test-retest reliability revealed excellent reproducibility (ICC = 0.96). Construct validity was good, demonstrating statistically significant associations between total FIS score and global ratings of oral health (p=0.007) and overall wellbeing (p=0.002), as well as for the subscale scores (p<0.05) with exception of the financial burden subscale. The FIS was also able to discriminate between children with and without dental caries experience and malocclusions (p<0.05). Satisfactory psychometric results for the Peruvian Spanish FIS confirm it as a reliable, valid instrument for assessing the impact on the family caused by children's oral conditions. Sociedad Argentina de Investigación Odontológica.
Ahlström, Isabell; Hellström, Karin; Emtner, Margareta; Anens, Elisabeth
2015-03-01
To examine the test-retest reliability of the Swedish translated version of the Exercise Self-Efficacy Scale (S-ESES) in people with neurological disease and to examine internal consistency. Test-retest study. A total of 30 adults with neurological diseases including: Parkinson's disease; Multiple Sclerosis; Cervical Dystonia; and Charcot-Marie-Tooth disease. The S-ESES was sent twice by surface mail. Completion interval mean was 16 days apart. Weighted kappa, intraclass correlation coefficient 2,1 [ICC (2,1)], standard error of measurement (SEM), also expressed as a percentage value (SEM%), and Cronbach's alpha were calculated. The relative reliability of the test-retest results showed substantial agreement measured using weighted kappa (MD = 0.62) and a very high-reliability ICC (2,1) (0.92). Absolute reliability measured using SEM was 5.3 and SEM% was 20.7. Excellent internal consistency was shown, with an alpha coefficient of 0.91 (test 1) and 0.93 (test 2). The S-ESES is recommended for use in research and in clinical work for people with neurological diseases. The low-absolute reliability, however, indicates a limited ability to measure changes on an individual level.
Stroke and aphasia quality-of-life scale-39: Reliability and validity of the Turkish version.
Noyan-ErbaŞ, AyŞin; Toğram, Bülent
2016-10-01
The aim of this study was to adapt the stroke and aphasia quality-of-life scale-39 (SAQoL-39) to the Turkish language and carry out a reliability and validity study of the instrument in a group of patients with aphasia. The study was a descriptive study and contained three phases: adaptation of the SAQoL-39 to the Turkish language, administration of the scale to 30 aphasia patients and reliability and validity studies of the scale. Internal consistency was assessed with Cronbach's alpha and test-re-test reliability was explored (n = 14). The adaptation process was completed based on inter-rater agreement on the translated items and within the scope of final editing by the authors of the study. The SAQoL-39 in Turkish exhibited high test-re-test reliability (ICC =0.97) as well as acceptability with minimal missing data (0-1.4). This instrument exhibited high internal consistency (Cronbach's α = 0.70-0.97), domain-total correlations (r = 0.76-0.85) and inter-domain correlations (r = 0.40-0.68). The analysis shows that the Turkish version of SAQoL-39 is a scale that is highly acceptable, valid and reliable and can be easily used in evaluating the quality-of-life of Turkish people with aphasia.
Adaptation and validation of the Inventory of Family Protective Factors for the Portuguese culture
Augusto, Cláudia Cristina Vieira Carvalho de Oliveira Ferreira; Araújo, Beatriz Rodrigues; Rodrigues, Vítor Manuel Costa Pereira; de Figueiredo, Maria do Céu Aguiar Barbieri
2014-01-01
OBJECTIVES: to adapt and validate the Inventory of Family Protective Factors (IFPF) for the Portuguese culture. This instrument assesses protective factors that contribute to family resilience. Studies addressing resilience are embedded within the salutogenic paradigm, i.e. it addresses protective factors of individuals or groups without underestimating risk factors or vulnerability. METHOD: in order to assess the IFPF's linguistic and conceptual equivalence, the instrument was translated, retro-translated and the think-aloud protocol was used. We then verified the instrument's sensitiveness, reliability and validity of results to assess its psychometric characteristics. A factor analysis was performed of the principal components with varimax rotation of the scale's items and Cronbach's alpha coefficient was calculated for each dimension. A total of 85 families with disabled children, selected through simple random sampling, self-administered the instrument. RESULTS: the IFPF presents psychometric characteristics that are appropriate for the Portuguese population (Cronbach's alpha = .90). CONCLUSION: the IFPF was adapted and validated for the Portuguese culture and is an instrument to be used in studies intended to assess protective factors of family resilience. PMID:25591096
Adaptation and validation of the Inventory of Family Protective Factors for the Portuguese culture.
Augusto, Cláudia Cristina Vieira Carvalho de Oliveira Ferreira; Araújo, Beatriz Rodrigues; Rodrigues, Vítor Manuel Costa Pereira; de Figueiredo, Maria do Céu Aguiar Barbieri
2014-01-01
to adapt and validate the Inventory of Family Protective Factors (IFPF) for the Portuguese culture. This instrument assesses protective factors that contribute to family resilience. Studies addressing resilience are embedded within the salutogenic paradigm, i.e. it addresses protective factors of individuals or groups without underestimating risk factors or vulnerability. in order to assess the IFPF's linguistic and conceptual equivalence, the instrument was translated, retro-translated and the think-aloud protocol was used. We then verified the instrument's sensitiveness, reliability and validity of results to assess its psychometric characteristics. A factor analysis was performed of the principal components with varimax rotation of the scale's items and Cronbach's alpha coefficient was calculated for each dimension. A total of 85 families with disabled children, selected through simple random sampling, self-administered the instrument. the IFPF presents psychometric characteristics that are appropriate for the Portuguese population (Cronbach's alpha = .90). the IFPF was adapted and validated for the Portuguese culture and is an instrument to be used in studies intended to assess protective factors of family resilience.
Valdés, Patricio R; Alarcon, Ana M; Munoz, Sergio R
2013-03-01
To generate and validate a scale to measure the Informed Choice of contraceptive methods among women attending a family health care service in Chile. The study follows a multimethod design that combined expert opinions from 13 physicians, 3 focus groups of 21 women each, and a sample survey of 1,446 women. Data analysis consisted of a qualitative text analysis of group interviews, a factor analysis for construct validity, and kappa statistic and Cronbach alpha to assess scale reliability. The instrument comprises 25 items grouped into six categories: information and orientation, quality of treatment, communication, participation in decision making, expression of reproductive rights, and method access and availability. Internal consistency measured with Cronbach alpha ranged from 0.75 to 0.89 for all subscales (kappa, 0.62; standard deviation, 0.06), and construct validity was demonstrated from the testing of several hypotheses. The use of mixed methods contributed to developing a scale of Informed Choice that was culturally appropriate for assessing the women who participated in the family planning program. Copyright © 2013 Elsevier Inc. All rights reserved.
The Female Sexual Function Index (FSFI): linguistic validation of the Italian version.
Filocamo, Maria Teresa; Serati, Maurizio; Li Marzi, Vincenzo; Costantini, Elisabetta; Milanesi, Martina; Pietropaolo, Amelia; Polledro, Patrizio; Gentile, Barbara; Maruccia, Serena; Fornia, Samanta; Lauri, Irene; Alei, Rosanna; Arcangeli, Paola; Sighinolfi, Maria Chiara; Manassero, Francesca; Andretta, Elena; Palazzetti, Anna; Bertelli, Elena; Del Popolo, Giulio; Villari, Donata
2014-02-01
Although several new measurements for female sexual dysfunction (FSD) have recently been developed, the Female Sexual Function Index (FSFI) remains the gold standard for screening and one of the most widely used questionnaires. The Italian translation of the FSFI has been used in several studies conducted in Italy, but a linguistic validation of the Italian version does not exist. The aim of this study was to perform a linguistic validation of the Italian version of the FSFI. A multicenter cross-sectional study conducted in 14 urological and gynecological clinics, uniformly distributed over Italian territory. We performed all steps necessary to determine the reliability and the test-retest reliability of the Italian version of the FSFI. The study population was a convenience sample of 409 Italian women. The reliability of the questionnaire was calculated using Cronbach's alpha, which was considered weak, moderate, or high if its value was found less than 0.6, between 0.6 and 0.8, or equal to or greater than 0.8, respectively. The test-retest reliability was assessed for all women in the sample by calculating Pearson's concordance correlation coefficient for each domain and for the total score, both at baseline and after 15 days (r range between -1.00 to +1.00, where +1.00 indicates the strongest positive association). Cronbach's alpha coefficients for total and domain score were sufficiently high, ranging from 0.92 to 0.97 for the total sample. The test-retest procedure revealed that the concordance correlation coefficient was very high both for FSFI-I total score (Pearson's P = 0.93) and for each domain (Pearson's P always >0.92). For the first time in the literature, our study has produced a validated and reliable Italian version of the FSFI questionnaire. Consequently, the Italian FSFI can be used as a reliable tool for preliminary screening for female sexual dysfunction for Italian women. © 2013 International Society for Sexual Medicine.
Fundamentals of endoscopic surgery: creation and validation of the hands-on test.
Vassiliou, Melina C; Dunkin, Brian J; Fried, Gerald M; Mellinger, John D; Trus, Thadeus; Kaneva, Pepa; Lyons, Calvin; Korndorffer, James R; Ujiki, Michael; Velanovich, Vic; Kochman, Michael L; Tsuda, Shawn; Martinez, Jose; Scott, Daniel J; Korus, Gary; Park, Adrian; Marks, Jeffrey M
2014-03-01
The Fundamentals of Endoscopic Surgery™ (FES) program consists of online materials and didactic and skills-based tests. All components were designed to measure the skills and knowledge required to perform safe flexible endoscopy. The purpose of this multicenter study was to evaluate the reliability and validity of the hands-on component of the FES examination, and to establish the pass score. Expert endoscopists identified the critical skill set required for flexible endoscopy. They were then modeled in a virtual reality simulator (GI Mentor™ II, Simbionix™ Ltd., Airport City, Israel) to create five tasks and metrics. Scores were designed to measure both speed and precision. Validity evidence was assessed by correlating performance with self-reported endoscopic experience (surgeons and gastroenterologists [GIs]). Internal consistency of each test task was assessed using Cronbach's alpha. Test-retest reliability was determined by having the same participant perform the test a second time and comparing their scores. Passing scores were determined by a contrasting groups methodology and use of receiver operating characteristic curves. A total of 160 participants (17 % GIs) performed the simulator test. Scores on the five tasks showed good internal consistency reliability and all had significant correlations with endoscopic experience. Total FES scores correlated 0.73, with participants' level of endoscopic experience providing evidence of their validity, and their internal consistency reliability (Cronbach's alpha) was 0.82. Test-retest reliability was assessed in 11 participants, and the intraclass correlation was 0.85. The passing score was determined and is estimated to have a sensitivity (true positive rate) of 0.81 and a 1-specificity (false positive rate) of 0.21. The FES hands-on skills test examines the basic procedural components required to perform safe flexible endoscopy. It meets rigorous standards of reliability and validity required for high-stakes examinations, and, together with the knowledge component, may help contribute to the definition and determination of competence in endoscopy.
Hu, Yinhuan; Zhang, Zixia; Xie, Jinzhu; Wang, Guanping
2017-02-01
The objective of this study is to describe the development of the Outpatient Experience Questionnaire (OPEQ) and to assess the validity and reliability of the scale. Literature review, patient interviews, Delphi method and Cross-sectional validation survey. Six comprehensive public hospitals in China. The survey was carried out on a sample of 600 outpatients. Acceptability of the questionnaire was assessed according to the overall response rate, item non-response rate and the average completion time. Correlation coefficients and confirmatory factor analysis were used to test construct validity. Delphi method was used to assess the content validity of the questionnaire. Cronbach's coefficient alpha and split-half reliability coefficient were used to estimate the internal reliability of the questionnaire. The overall response rate was 97.2% and the item non-response rate ranged from 0% to 0.3%. The mean completion time was 6 min. The Spearman correlations of item-total score ranged from 0.466 to 0.765. The results of confirmatory factor analysis showed that all items had factor loadings above 0.40 and the dimension intercorrelation ranged from 0.449 to 0.773, the goodness of fit of the questionnaire was reasonable. The overall authority grade of expert consultation was 0.80 and Kendall's coefficient of concordance W was 0.186. The Cronbach's coefficients alpha of six dimensions ranged from 0.708 to 0.895, the split-half reliability coefficient (Spearman-Brown coefficient) was 0.969. The OPEQ is a promising instrument covering the most important aspects which influence outpatient experiences of comprehensive public hospital in China. It has good evidence for acceptability, validity and reliability. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Reliability and validation of the Dutch Achilles tendon Total Rupture Score.
Opdam, K T M; Zwiers, R; Wiegerinck, J I; Kleipool, A E B; Haverlag, R; Goslings, J C; van Dijk, C N
2018-03-01
Patient-reported outcome measures (PROMs) have become a cornerstone for the evaluation of the effectiveness of treatment. The Achilles tendon Total Rupture Score (ATRS) is a PROM for outcome and assessment of an Achilles tendon rupture. The aim of this study was to translate the ATRS to Dutch and evaluate its reliability and validity in the Dutch population. A forward-backward translation procedure was performed according to the guidelines of cross-cultural adaptation process. The Dutch ATRS was evaluated for reliability and validity in patients treated for a total Achilles tendon rupture from 1 January 2012 to 31 December 2014 in one teaching hospital and one academic hospital. Reliability was assessed by the intraclass correlation coefficients (ICC), Cronbach's alpha and minimal detectable change (MDC). We assessed construct validity by calculation of Spearman's rho correlation coefficient with domains of the Foot and Ankle Outcome Score (FAOS), Victorian Institute of Sports Assessment-Achilles questionnaire (VISA-A) and Numeric Rating Scale (NRS) for pain in rest and during running. The Dutch ATRS had a good test-retest reliability (ICC = 0.852) and a high internal consistency (Cronbach's alpha = 0.96). MDC was 30.2 at individual level and 3.5 at group level. Construct validity was supported by 75 % of the hypothesized correlations. The Dutch ATRS had a strong correlation with NRS for pain during running (r = -0.746) and all the five subscales of the Dutch FAOS (r = 0.724-0.867). There was a moderate correlation with the VISA-A-NL (r = 0.691) and NRS for pain in rest (r = -0.580). The Dutch ATRS shows an adequate reliability and validity and can be used in the Dutch population for measuring the outcome of treatment of a total Achilles tendon rupture and for research purposes. Diagnostic study, Level I.
Indrebø, Kirsten Lerum; Andersen, John Roger; Natvig, Gerd Karin
2014-01-01
The purpose of this study was to adapt the Ostomy Adjustment Scale to a Norwegian version and to assess its construct validity and 2 components of its reliability (internal consistency and test-retest reliability). One hundred fifty-eight of 217 patients (73%) with a colostomy, ileostomy, or urostomy participated in the study. Slightly more than half (56%) were men. Their mean age was 64 years (range, 26-91 years). All respondents had undergone ostomy surgery at least 3 months before participation in the study. The Ostomy Adjustment Scale was translated into Norwegian according to standard procedures for forward and backward translation. The questionnaire was sent to the participants via regular post. The Cronbach alpha and test-retest were computed to assess reliability. Construct validity was evaluated via correlations between each item and score sums; correlations were used to analyze relationships between the Ostomy Adjustment Scale and the 36-item Short Form Health Survey, the Quality of Life Scale, the Hospital Anxiety & Depression Scale, and the General Self-Efficacy Scale. The Cronbach alpha was 0.93, and test-retest reliability r was 0.69. The average correlation quotient item to sum score was 0.49 (range, 0.31-0.73). Results showed moderate negative correlations between the Ostomy Adjustment Scale and the Hospital Anxiety and Depression Scale (-0.37 and -0.40), and moderate positive correlations between the Ostomy Adjustment Scale and the 36-item Short Form Health Survey, the Quality of Life Scale, and the General Self-Efficacy Scale (0.30-0.45) with the exception of the pain domain in the Short Form 36 (0.28). Regression analysis showed linear associations between the Ostomy Adjustment Scale and sociodemographic and clinical variables with the exception of education. The Norwegian language version of the Ostomy Adjustment Scale was found to possess construct validity, along with internal consistency and test-retest reliability. The instrument is sensitive for sociodemographic and clinical variables pertinent to persons with urostomies, colostomies, and ileostomies.
Kourmousi, Ntina; Darviri, Christina; Varvogli, Liza; Alexopoulos, Evangelos C
2015-01-01
The Teacher Stress Inventory (TSI) is an instrument for measuring occupational stress in teachers. This study aimed to translate and adapt it for use in Greece, and then assess its reliability and validity. The Greek versions of the TSI and the 14-item Perceived Stress Scale (PSS-14) were posted on all Greek educators' official sites during May 2012. A nationwide sample of 3,447 teachers of all levels and specialties completed the questionnaires via the Internet. Reliability was determined by the calculation of Cronbach's alpha coefficient. Confirmatory factor analysis was conducted and validity was further examined by investigating the correlation of the TSI with the PSS-14 and their association with demographics and work-related factors. Satisfactory Cronbach's alpha values (above 0.70) were found for all TSI dimensions. Confirmatory factor analysis confirmed the two-factor construct of TSI (root mean square error of approximation, comparative fit index, and goodness-of-fit index values were 0.079, 0.956, and 0.951, respectively), confirming the pre-established theory for the two latent variables, Stress Sources and Stress Manifestations. Significant correlations were found between TSI subscales, PSS-14 sex, age, lack of support, and students' difficulties. The Greek version of the TSI was found to have satisfactory psychometric properties, and its use for assessing stress in Greek teachers is warranted.
Al Hadid, Lourance A; Al-Rajabi, Omaymah; AlBarmawi, Marwa; Yousef Sayyah, Najah Sayyah; Toqan, Lwiza Moh'd
2018-03-01
Students' professional choice to proceed in midwifery is influenced by many factors. This study validated an instrument developed to assess students' attitudes toward midwifery in Jordan. It also addressed the motivating and de-motivating factors influencing students' decision concerning joining and continuing in midwifery. A descriptive, cross-section study was conducted on a convenience sample of 374 midwifery students representing private, governmental, and military midwifery colleges. The researchers developed the study questionnaire through conducting a comprehensive literature review, organizing common themes and consulting experts. Exploratory factor analysis and tests of normality and reliability, including Cronbach's Alpha and Bartlett's test, were used in the analysis. The result was three factors were explained by 23 items. They were as follows: professional knowledge, professional motivation factors, and de-motivating professional factors. The first 8 items explained nearly 61% of the variance. Cronbach's Alpha was 0.834 with a range of 0.835-0.839. The Spearman-Brown coefficient was 0.81 and Guttman Split-Half coefficient was 0.83. Issues of reliability and validity require a repetitive process of testing under a range of circumstances to ensure both stability and representation of the construct. However, addressing factors found to have impact of students' decisions is crucial to improve retention of high quality students. Copyright © 2018. Published by Elsevier Ltd.
Martin, Lisa A; Hassinger, Jane A; Seewald, Meghan; Harris, Lisa H
We report on the development of a scale measuring abortion providers' experiences of stigma. Using previous measures, qualitative data, and expert review, we created a 49-item question pool. We administered questions to 315 abortion providers before participation in the Providers Share Workshop. We explored the factor structure and item quality using exploratory factor analysis. We assessed reliability using Cronbach's alpha. To test construct validity, we calculated Pearson's correlation coefficients between the stigma scales, the Maslach Burnout Inventory, and the K10 measure of psychological distress. We used Stata SE/12.0 for analyses. Factor analysis revealed a 35-item, five-factor model: worries about disclosure, internalized states, social judgment, social isolation, and discrimination (Cronbach's alphas 0.79-0.94). Our stigma measure was correlated with psychological distress (r = 0.40; p < .001), and with Maslach Burnout Inventory's emotional exhaustion (r = 0.27; p < .001), and depersonalization (0.23; p < .001) subscales, and was inversely correlated with Maslach Burnout Inventory's personal accomplishment subscale (r = -0.15; p < .05). Psychometric analysis of this scale reveals that it is a reliable and valid tool for measuring stigma in abortion providers, and may be helpful in evaluating stigma reduction programs. Copyright © 2017 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.
Navidpour, Fariba; Dolatian, Mahrokh; Yaghmaei, Farideh; Majd, Hamid Alavi; Hashemi, Seyed Saeed
2015-04-23
Pregnant women tend to experience anxiety and stress when faced with the changes to their biology, environment and personal relationships. The identification of these factors and the prevention of their side effects are vital for both mother and fetus. The present study was conducted to validate and to examine the factor structure of the Persian version of the Pregnancy's Worries and Stress Questionnaire. The 25-item PWSQ was first translated by specialists into Persian. The questionnaire's validity was determined using face, content, criterion and construct validity and reliability of questionnaire was examined using Cronbach's alpha. Confirmatory factor analysis was performed in AMOS and SPSS 21. Participants included healthy Iranian pregnant women (8-39 weeks) who refer to selected hospitals for prenatal care. Hospitals included private, social security and university hospitals and selected through the random cluster sampling method. The results of validity and reliability assessments of the questionnaire were acceptable. Cronbach's alpha calculated showed a high internal consistency of 0.89. The confirmatory factor analysis using the c2, CMIN/DF, IFI, CFI, NFI and NNFI indexes showed the 6-factor model to be the best fitted model for explaining the data. The questionnaire was translated into Persian to examine stress and worry specific to Iranian pregnant women. The psychometric results showed that the questionnaire is suitable for identifying Iranian pregnant women with pregnancy-related stress.
Ghisi, Gabriela Lima de Melo; Grace, Sherry L; Thomas, Scott; Evans, Michael F; Oh, Paul
2013-06-01
To develop and psychometrically validate a tool to assess information needs in cardiac rehabilitation (CR) patients. After a literature search, 60 information items divided into 11 areas of needs were identified. To establish content validity, they were reviewed by an expert panel (N=10). Refined items were pilot-tested in 34 patients on a 5-point Likert-scale from 1 "really not helpful" to 5 "very important". A final version was generated and psychometrically tested in 203 CR patients. Test-retest reliability was assessed via the intraclass correlation coefficient (ICC), the internal consistency using Cronbach's alpha, and criterion validity was assessed with regard to patient's education and duration in CR. Five items were excluded after ICC analysis as well as one area of needs. All 10 areas were considered internally consistent (Cronbach's alpha>0.7). Criterion validity was supported by significant differences in mean scores by educational level (p<0.05) and duration in CR (p<0.001). The mean total score was 4.08 ± 0.53. Patients rated safety as their greatest information need. The INCR Tool was demonstrated to have good reliability and validity. This is an appropriate tool for application in clinical and research settings, assessing patients' needs during CR and as part of education programming. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Bower, W F; Vlantis, A C; Chung, T M L; Cheung, S K C; Bjordal, K; van Hasselt, C A
2009-07-01
High convergent and discriminant validity between subscales was achieved after the translation of EORTC QLQ-H&N35 into Cantonese. Most subscales were assessing distinct components of quality of life (QoL). The study aimed to translate the EORTC QLQ-H&N35 cancer module into Cantonese and to confirm validity and reliability for use in a Hong Kong head and neck (H&N) cancer population. An ethnocentric forward-backward translation of EORTC QLQ-H&N35 was conducted by bilingual head and neck health professionals. Discrepancies were identified and problematic wording and concepts revised. Further review preceded pilot testing in 119 postoperative H&N cancer patients. Internal consistency within each subscale, convergent and discriminant validity to check the item relevance and item representativeness within and between subscales were examined. Mean and standard deviations of each subscale and single item and Cronbach's alpha coefficients for subscales were calculated. Six of seven subscales achieved standard reliability (Cronbach's alpha coefficient >0.7). Correlation coefficients between an item and its own subscale were significantly higher than the coefficients with other subscales. Scaling success was found in all subscales. Pearson's correlation coefficient between subscales was <0.70, except between the subscales swallowing and trouble with social eating (r = 0.795), and speech problems and social contact (r = 0.754).
Tuomikoski, Anna-Maria; Ruotsalainen, Heidi; Mikkonen, Kristina; Miettunen, Jouko; Kääriäinen, Maria
2018-06-05
Mentors require competence at a diverse array of skills to mentor students during clinical practice. According to the latest evidence, competence at mentoring includes: knowledge, skills and attributes of individual students' learning objectives, core elements of nursing, learning processes, a reciprocal and trustful relationship, feedback, evaluation, cooperation with stakeholders, and the mentor's personal qualities. The purpose of the study was to test psychometric properties of a mentor's competence instrument developed to self-evaluate mentors' competence at mentoring nursing students in clinical practice. A cross-sectional, descriptive, explorative study design was used. Data were collected from mentors at five university hospitals in Finland in 2016. A total of 576 mentors participated in this study. The instrument was developed through systematic review, experts' evaluations, and pilot versions of the instrument tested in previous studies. The construct validity and reliability of the instrument were tested using exploratory factor analysis (EFA) with promax rotation and Cronbach's alpha. A 10-factor model showed that the instrument has acceptable construct validity. Cronbach's alpha values for the subscales observed ranged from 0.76 to 0.90. The instrument exhibited acceptable psychometric properties, thereby proving itself a valuable tool for evaluating mentors' competence at mentoring students. Further assessments of its reliability, validity and generality for measuring mentor's competence for mentoring students in different contexts and cultures are recommended. Copyright © 2018 Elsevier Ltd. All rights reserved.
de Bruin, Marijn; Viechtbauer, Wolfgang; Hospers, Harm J; Schaalma, Herman P; Kok, Gerjo
2009-11-01
Clinical trials of behavioral interventions seek to enhance evidence-based health care. However, in case the quality of standard care provided to control conditions varies between studies and affects outcomes, intervention effects cannot be directly interpreted or compared. The objective of the present study was to examine whether standard care quality (SCQ) could be reliably assessed, varies between studies of highly active antiretroviral HIV-adherence interventions, and is related to the proportion of patients achieving an undetectable viral load ("success rate"). Databases were searched for relevant articles. Authors of selected studies retrospectively completed a checklist with standard care activities, which were coded to compute SCQ scores. The relationship between SCQ and the success rates was examined using meta-regression. Cronbach's alpha, variability in SCQ, and relation between SCQ and success rate. Reliability of the SCQ instrument was high (Cronbach's alpha = .91). SCQ scores ranged from 3.7 to 27.8 (total range = 0-30) and were highly predictive of success rate (p = .002). Variation in SCQ provided to control groups may substantially influence effect sizes of behavior change interventions. Future trials should therefore assess and report SCQ, and meta-analyses should control for variability in SCQ, thereby producing more accurate estimates of the effectiveness of behavior change interventions. PsycINFO Database Record (c) 2009 APA, all rights reserved.
Ripoll, Carmen; Salazar, José; Bobes, Julio
2010-01-01
Narcissistic personality is an important component of personality disorders which are prevalent in those presenting drug abuse or dependence. Assessment instruments usually consider self-esteem, narcissism and covert narcissism, but although Spanish versions of instruments for self-esteem and narcissism are available, there is no available test for covert narcissism. OBJECTIVE. To test the validity of the Spanish version of the Hypersensitive Narcissism Scale (HSNS) in individuals presenting drug abuse or dependence. In a sample of 79 outpatients, we assessed reliability by means of Cronbach's alpha and the intraclass correlation coefficient (ICC), construct validity through factor analysis, and concurrent validity by means of the correlation between the HSNS and measures of severity, disability, self-esteem, grandiose narcissism and personality disorders. Reliability of the HSNS total scale score was satisfactory (Cronbach's alpha = 0,73, ICC = 0,67), though some items would require further consideration. Factor analysis showed good construct validity with three factors compatible with the theory of covert narcissism. With regard to concurrent validity, covert narcissism (HSNS) correlated positively with open narcissism, severity and disability due to drug use, and negatively with self-esteem. Highest scores on the HSNS corresponded to borderline, narcissistic and passive-aggressive personality disorders. The Spanish version of the HSNS could be a valid instrument for the assessment of covert narcissism in those treated for drug abuse or dependence.
Coaching leadership: leaders' and followers' perception assessment questionnaires in nursing
Cardoso, Maria Lúcia Alves Pereira; Ramos, Laís Helena; D'Innocenzo, Maria
2014-01-01
ABSTRACT Objective: To describe the development, content analysis, and reliability of two questionnaires to assess the perception of nurse leaders, nurse technicians, and licensed practical nurses – coached in the practice of leadership and the relation with the dimensions of the coaching process. Methods: This was a methodological study with a quantitative and qualitative approach, which had the goal of instrumentation in reference to the construction and validation of measuring instruments. The instrument proposition design was based on the literature on leadership, coaching, and assessment of psychometric properties, subjected to content validation as to clarity, relevance, and applicability in order to validate the propositions through the consensus of judges, using the Delphi technique, in 2010. The final version of the questionnaires was administered to 279 nurses and 608 nurse technicians and licensed practical nurses, at two university hospitals and two private hospitals. Results: The Cronbach's alpha value with all items of the self-perception instrument was very high (0.911). The team members' instrument of perception showed that for all determinants and for each dimension of the coaching process, Cronbach's overall alpha value (0.952) was considered quite high, pointing to a very strong consistency of the scale. Confirmatory analysis showed that the models were well adjusted. Conclusion: From the statistical validation we compared the possibility of reusing the questionnaires for other study samples, because there was evidence of reliability and applicability. PMID:24728249
Kim, Chun-Ja; Park, Eunyoung; Schlenk, Elizabeth A; Kim, Moonsun; Kim, Dae Jung
2016-04-01
The purpose of the study was to examine the reliability and validity of the Adherence to Refills and Medications Scale-Korean (ARMS-K) among Korean adults with type 2 diabetes. The Korean translated ARMS-K was back-translated to ensure translation equivalency. A cross-sectional survey was used to evaluate the psychometric properties with exploratory factor analysis for validity and Cronbach's alpha coefficients for reliability. The factor analysis of construct validity identified 3 dimensions of the ARMS-K, explaining 54.7% of the total variance. The internal consistency reliability for the total instrument was acceptable with a Cronbach's alpha of .801. There was good correlation between the ARMS-K and 8-item Morisky Medication Adherence Scale-Korean version (r = -0.698), indicating that these scales measure theoretically related constructs as evidence of convergent validity. As evidence of known groups validity, there was a significant association between the ARMS-K score and glycemic control (P = .048), indicating that the good glycemic controlled group was more likely to have a higher rate of adherence to refills and medications than the poor glycemic controlled group. These results support the cross-cultural applicability of the concepts underlying the ARMS-K. The ARMS-K can be used not only to assess adherence to refills and medications in Koreans with diabetes but also to examine the potential role of adherence to refills and medications in enhanced glycemic control of people with diabetes in a variety of clinical settings. © 2016 The Author(s).
Lee, Jennifer; Koh, Jung Hee; Kwok, Seung-Ki; Park, Sung-Hwan
2016-05-01
This study was conducted to generate and validate a cross-culturally adapted Korean version of the xerostomia inventory (XI), an 11-item questionnaire designed to measure the severity of xerostomia. The original English version of the XI was translated into Korean according to the guidelines for cross-cultural adaptation of health-related quality-of-life measures. Among a prospective cohort of primary Sjögren's syndrome (pSS) in Korea, 194 patients were analyzed. Internal consistency was evaluated by using Cronbach's alpha, and test-retest reliability was obtained by using an intraclass correlation coefficient (ICC) analysis. Construct validity was investigated by performing a correlation analysis between XI total score and salivary flow rate (SFR). Cronbach's alpha for internal consistency was 0.868, and the ICC for test-retest reliability ranged from 0.48 to 0.827, with a median value of 0.72. Moderate negative correlations between XI score and stimulated SFR, unstimulated SFR, and differential (stimulated minus unstimulated) SFR were observed (Spearman's rho, ρ = -0.515, -0.447, and -0.482, respectively; P < 0.001). The correlation analysis between the visual analogue scale (VAS) score of overall dryness and SFR indicated a smaller ρ value (-0.235 [P = 0.006], -0.243 [P = 0.002], and -0.252 [P = 0.003], respectively), which supports that XI more accurately reflects the degree of xerostomia in the pSS patients. In conclusion, the Korean version of the XI is a reliable tool to estimate the severity of xerostomia in patients with pSS.
Saffari, Mohsen; Amini, Hossein; Sheykh-Oliya, Zarindokht; Pakpour, Amir H; Koenig, Harold G
2017-12-01
Assessing spirituality in healthy pregnant women may lead to supportive interventions that will improve their care. A psychometrically valid measure such as the Daily Spiritual Experiences Scale (DSES) may be helpful in this regard. The current study sought to adapt a Persian version of DSES for use in pregnancy. A total of 377 pregnant women were recruited from three general hospitals located in Tehran, Iran. Administered scales were the DSES, Duke University Religion Index, Santa Clara Strength of Religious Faith scale, and Depression Anxiety Stress Scale, as well as demographic measures. Reliability of the DSES was tested using Cronbach's alpha for internal consistency and the intraclass correlation coefficient (ICC) for test-retest stability. Scale validity was assessed by criterion-related tests, known-groups comparison, and exploratory factor analysis. Participant's mean age was 27.7 (4.1), and most were nulliparous (70%). The correlation coefficient between individual items on the scale and the total score was greater than 0.30 in most cases. Cronbach's alpha for the scale was 0.90. The ICC for 2-week test-retest reliability was high (0.86). Relationships between similar and dissimilar scales indicated acceptable convergent and divergent validity. The factor structure of the scale indicated a single factor that explained 59% of the variance. The DSES was found to be a reliable and valid measure of spirituality in pregnant Iranian women. This scale may be used to examine the relationship between spirituality and health outcomes, research that may lead to supportive interventions in this population.
Sani, Gabriele; Vöhringer, Paul A; Barroilhet, Sergio A; Koukopoulos, Alexia E; Ghaemi, S Nassir
2018-05-01
It has been proposed that the broad major depressive disorder (MDD) construct is heterogenous. Koukopoulos has provided diagnostic criteria for an important subtype within that construct, "mixed depression" (MxD), which encompasses clinical pictures characterized by marked psychomotor or inner excitation and rage/anger, along with severe depression. This study provides psychometric validation for the first rating scale specifically designed to assess MxD symptoms cross-sectionally, the Koukopoulos Mixed Depression Rating Scale (KMDRS). 350 patients from the international mood network (IMN) completed three rating scales: the KMDRS, Montgomery-Asberg Depression Rating Scale (MADRS) and Young Mania Rating Scale (YMRS). KMDRS' psychometric properties assessed included Cronbach's alpha, inter-rater reliability, factor analysis, predictive validity, and Receiver Operator Curve analysis. Internal consistency (Cronbach's alpha = 0.76; 95% CI 0.57, 0.94) and interrater reliability (kappa = 0.73) were adequate. Confirmatory factor analysis identified 2 components: anger and psychomotor excitation (80% of total variance). Good predictive validity was seen (C-statistic = 0.82 95% CI 0.68, 0.93). Severity cut-off scores identified were as follows: none (0-4), possible (5-9), mild (10-15), moderate (16-20) and severe (> 21) MxD. Non DSM-based diagnosis of MxD may pose some difficulties in the initial use and interpretation of the scoring of the scale. Moreover, the cross-sectional nature of the evaluation does not verify the long-term stability of the scale. KMDRS was a reliable and valid instrument to assess MxD symptoms. Copyright © 2018 Elsevier B.V. All rights reserved.
Shao, Jing; Tang, Leiwen; Ye, Zhihong
For the stabilization of the nursing profession in mainland China, a valid and reliable nursing work environment instrument, grounded in China's context, should be developed to better provide rigorous evidence for policy makers. The purpose of the current research was to further develop a scale that could capture the characteristics of the nursing work environment in mainland China. A convenience sample of 542 nurses employed in a tertiary hospital of mainland China completed the 108-item Chinese Nursing Work Environment (C-NWE) Scale (1st ed.). Items that did not differentiate between respondents with the highest and lowest 27% of total scores and those that did not meet criteria for factor loadings were set aside. Exploratory factor analysis based on the maximum likelihood method was used to identify the structure of the scale. The chi-square test was used to evaluate model fit, and expert review was conducted to test content validity. Reliability was estimated using Cronbach's alpha coefficient. The revised C-NWE Scale, which consists of nine subscales and 47 items, is a simplified version of the C-NWE (1st ed.). Using exploratory maximum likelihood factor analysis, the normed chi-square fit index for a nine-factor solution was 1.97. The content validity index for the total scale was 0.93; Cronbach's alpha was .94. Initial evidence of the psychometric properties of C-NWE scores was presented. Further studies could be conducted in various settings to identify the C-NWE Scale's validity and reliability.
Validity and reliability of the Multidimensional Body Image Scale in Malaysian university students.
Gan, W Y; Mohd, Nasir M T; Siti, Aishah H; Zalilah, M S
2012-12-01
This study aimed to evaluate the validity and reliability of the Multidimensional Body Image Scale (MBIS), a seven-factor, 62-item scale developed for Malaysian female adolescents. This scale was evaluated among male and female Malaysian university students. A total of 671 university students (52.2% women and 47.8% men) completed a self-administered questionnaire on MBIS, Eating Attitude Test-26, and Rosenberg Self-Esteem Scale. Their height and weight were measured. Results in confirmatory factor analysis showed that the 62-item MBIS reported poor fit to the data, xhi2/df = 4.126, p < 0.001, CFI = 0.808, SRMR = 0.070, RMSEA = 0.068 (90% CI = 0.067, 0.070). After re-specification of the model, the model fit was improved with 46 items remaining, chi2/df = 3.346, p < 0.001, CFI = 0.903, SRMR = 0.053, RMSEA = 0.059 (90% CI = 0.057, 0.061), and the model showed good fit to the data for men and women separately. This 46-item MBIS had good internal consistency in both men (Cronbach's alpha = 0.88) and women (Cronbach's alpha = 0.92). In terms of construct validity, it showed positive correlations with disordered eating and body weight status, but negative correlation with self-esteem. Also, this scale discriminated well between participants with and without disordered eating. The MBIS-46 demonstrated good reliability and validity for the evaluation of body image among university students. Further studies need to be conducted to confirm the validation results of the 46-item MBIS.
Warkentin, Sarah; Mais, Laís Amaral; Latorre, Maria do Rosário Dias de Oliveira; Carnell, Susan; Taddei, José Augusto de Aguiar Carrazedo
2016-07-19
Recent national surveys in Brazil have demonstrated a decrease in the consumption of traditional food and a parallel increase in the consumption of ultra-processed food, which has contributed to a rise in obesity prevalence in all age groups. Environmental factors, especially familial factors, have a strong influence on the food intake of preschool children, and this has led to the development of psychometric scales to measure parents' feeding practices. The aim of this study was to test the validity of a translated and adapted Comprehensive Feeding Practices Questionnaire in a sample of Brazilian preschool-aged children enrolled in private schools. A transcultural adaptation process was performed in order to develop a modified questionnaire (43 items). After piloting, the questionnaire was sent to parents, along with additional questions about family characteristics. Test-retest reliability was assessed in one of the schools. Factor analysis with oblique rotation was performed. Internal reliability was tested using Cronbach's alpha and correlations between factors, discriminant validity using marker variables of child's food intake, and convergent validity via correlations with parental perceptions of perceived responsibility for feeding and concern about the child's weight were also performed. The final sample consisted of 402 preschool children. Factor analysis resulted in a final questionnaire of 43 items distributed over 6 factors. Cronbach alpha values were adequate (0.74 to 0.88), between-factor correlations were low, and discriminant validity and convergent validity were acceptable. The modified CFPQ demonstrated significant internal reliability in this urban Brazilian sample. Scale validation within different cultures is essential for a more comprehensive understanding of parental feeding practices for preschoolers.
Wehrli, Martina; Hensler, Stefanie; Schindele, Stephan; Herren, Daniel B; Marks, Miriam
2016-09-01
The brief Michigan Hand Outcomes Questionnaire (briefMHQ) was developed as a shorter version of the Michigan Hand Outcomes Questionnaire (MHQ), but its measurement properties have not been investigated in patients with Dupuytren contracture. The objective of the study was to investigate the reliability, validity, responsiveness, and interpretability of the briefMHQ. Fifty-seven patients diagnosed with Dupuytren contracture completed the briefMHQ as well as the full-length MHQ and Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) questionnaire at baseline. Two to 14 days after baseline and 1 year after collagenase injection or surgery, patients again filled out the briefMHQ. Reliability was determined using the intraclass correlation coefficient and by calculating internal consistency (Cronbach alpha). Validity was tested by quantifying correlations with the full-length MHQ and QuickDASH. Responsiveness, based on the standardized response mean and the minimally clinically important change, was also determined. The briefMHQ had an intraclass correlation coefficient of 0.87, Cronbach alpha of 0.88, and correlations of r = 0.88 and -0.82 with the original MHQ and QuickDASH, respectively. The standardized response mean was 0.9 and the minimally clinically important change was 7 points. Overall, the briefMHQ demonstrates excellent reliability, good validity, and high responsiveness in patients with Dupuytren contracture. The briefMHQ is an accurate and time-saving tool to evaluate patients with Dupuytren contracture and the effect of a corresponding treatment. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Navarro-Colom, M; Sendra-Lluis, M A; Castillo-Masa, A M; Robleda, G
2015-01-01
The Behavioral Pain Scale (BPS) is a tool of pain assessment that often gives contradictory results when used by different raters. To assess internal consistency and interrater reliability of BPS scale in the pain assessment performed by intensives care nurses. A prospective observational study in 34 mechanically-ventilated patients, carried out in an Intensive Care Unit from April to June 2012. Variables analyzed included demographic characteristics, diagnosis of referral, clinical status, pain and sedation level. Pain was assessed by two nurses independently at rest (T1) and during a mobilization procedure (T2) using the BPS scale. Internal consistency was calculated by Cronbach's alpha, and intraobserver reliability was determined with the intraclass correlation coefficient (ICC), with a confidence interval (CI) of 95%. This study was approved by the Ethical Committee for Clinical Research. One-hundred and twenty-eight pain assessments were performed. The Cronbach's alpha of total BPS score at rest was 0.66 (95%CI: 0.33 to 0.83) and during mobilization of 0.73 (95%CI: 0.47 to 0.87). The CCI of total BPS score was 0.50 (95%CI: 0.19 to 0.71) at rest and 0.58 (95%CI: 0.31 to 0.77) during mobilization. The level of internal consistency of the scale is appropriate and moderate interrater agreement. For the BPS useful in clinical practice, it is imperative that nurses have prior experience with a regulated use of this tool. Copyright © 2014 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
Panah, Sara Hojat; Baharlouie, Hamze; Rezaeian, Zahra Sadat; Hawker, Gilian
2016-01-01
The present study aimed to translate and evaluate the reliability and validity of the Persian version of the 11-item Intermittent and Constant Osteoarthritis Pain (ICOAP) measure in Iranian subjects with Knee Osteoarthritis (KOA). The ICOAP questionnaire was translated according to the Manufacturers Alliance for Productivity and Innovation (MAPI) protocol. The procedure consisted of forward and backward translation, as well as the assessment of the psychometric properties of the Persian version of the questionnaire. A sample of 230 subjects with KOA was asked to complete the Persian versions of ICOAP and Knee injury and Osteoarthritis Outcome Score (KOOS). The ICOAP was readministered to forty subjects five days after the first visit. Test-retest reliability was assessed using Intraclass Correlation Coefficient (ICC), and internal consistency was assessed by Cronbach's alpha and item-total correlation. The correlation between ICOAP and KOOS was determined using Spearman's correlation coefficient. Subjects found the Persian-version of the ICOAP to be clear, simple, and unambiguous, confirming its face validity. Spearman correlations between ICOAP total and subscale scores with KOOS scores were between 0.5 and 0.7, confirming construct validity. Cronbach's alpha, used to assess internal consistency, was 0.89, 0.93, and 0.92 for constant pain, intermittent pain, and total pain scores, respectively. The ICC was 0.90 for constant pain and 0.91 for the intermittent pain and total pain score. The Persian version of the ICOAP is a reliable and valid outcome measure that can be used in Iranian subjects with KOA.
Pourmomeny, Abbas Ali; Ghanei, Behnaz; Alizadeh, Farshid
2018-05-01
Assessment instruments are essential for research, allowing diagnosis and evaluating treatment outcomes in subjects with lower urinary tract disorders of both genders. The purpose of this study was to translate the Male Lower Urinary Tract Symptoms (MLUTS) Questionnaire and determine its psychometric properties in Persian subjects. After getting permission from the International Consultation on Incontinence Modular Questionnaire (ICIQ) web site, the forward and backward translation of the MLUTS questionnaire were carried out by researcher team. The content/face validity, construct validity and reliability were assessed in a sample of MLUTS Iranian patients by measuring with the Cronbach's alpha test. In total, 121 male patients were included in the study. The mean age of the patients was 60.5 years. Cronbach alpha value was 0.757, consecrated the internal consistency of the form (r > 0.7). The internal consistency of each question was examined separately and found to be over 0.7. For the evaluation of reliability test-retest was done, the test was administered to 20% of the patients for a second time with an interval of 1-2 weeks. The intraclass correlation coefficient (ICC) score was 0.901. The Correlation coefficient between the MLUTS and International Prostate Symptoms Score (IPSS) was 0.879. ICIQ-MLUTS is a robust instrument, which can be used for evaluating male LUTS in Persian patients. We believe that the Persian version of the MLUTS is an important tool for research and clinical setting. © 2017 John Wiley & Sons Australia, Ltd.
Vergara-Romero, Manuel; Morales-Asencio, José Miguel; Morales-Fernández, Angelines; Canca-Sanchez, Jose Carlos; Rivas-Ruiz, Francisco; Reinaldo-Lapuerta, Jose Antonio
2017-06-07
Preoperative anxiety is a frequent and challenging problem with deleterious effects on the development of surgical procedures and postoperative outcomes. To prevent and treat preoperative anxiety effectively, the level of anxiety of patients needs to be assessed through valid and reliable measuring instruments. One such measurement tool is the Amsterdam Preoperative Anxiety and Information Scale (APAIS), of which a Spanish version has not been validated yet. To perform a Spanish cultural adaptation and empirical validation of the APAIS for assessing preoperative anxiety in the Spanish population. A two-step forward/back translation of the APAIS scale was performed to ensure a reliable Spanish cultural adaptation. The final Spanish version of the APAIS questionnaire was administered to 529 patients between the ages of 18 to 70 undergoing elective surgery at hospitals of the Agencia Sanitaria Costa del Sol (Spain). Cronbach's alpha, homogeneity index, intra-class correlation coefficient, and confirmatory factor analysis were calculated to assess internal consistency and criteria and construct validity. Confirmatory factor analysis showed that a one-factor model was better fitted than a two-factor model, with good fitting patterns (root mean square error of approximation: 0.05, normed-fit index: 0.99, goodness-of-fit statistic: 0.99). The questionnaire showed high internal consistency (Cronbach's alpha: 0.84) and a good correlation with the Goldberg Anxiety Scale (CCI: 0.62 (95% CI: 0.55 to 0.68). The Spanish version of the APAIS is a valid and reliable preoperative anxiety measurement tool and shows psychometric properties similar to those obtained by similar previous studies.
Teamwork in the operating room: frontline perspectives among hospitals and operating room personnel.
Sexton, J Bryan; Makary, Martin A; Tersigni, Anthony R; Pryor, David; Hendrich, Ann; Thomas, Eric J; Holzmueller, Christine G; Knight, Andrew P; Wu, Yun; Pronovost, Peter J
2006-11-01
The Joint Commission on Accreditation of Healthcare Organizations is proposing that hospitals measure culture beginning in 2007. However, a reliable and widely used measurement tool for the operating room (OR) setting does not currently exist. OR personnel in 60 US hospitals were surveyed using the Safety Attitudes Questionnaire. The teamwork climate domain of the survey uses six items about difficulty speaking up, conflict resolution, physician-nurse collaboration, feeling supported by others, asking questions, and heeding nurse input. To justify grouping individual-level responses to a single score at each hospital OR level, the authors used a multilevel confirmatory factor analysis, intraclass correlations, within-group interrater reliability, and Cronbach's alpha. To detect differences at the hospital OR level and by caregiver type, the authors used multivariate analysis of variance (items) and analysis of variance (scale). The response rate was 77.1%. There was robust evidence for grouping individual-level respondents to the hospital OR level using the diverse set of statistical tests, e.g., Comparative Fit Index = 0.99, root mean squared error of approximation = 0.05, and acceptable intraclasss correlations, within-group interrater reliability values, and Cronbach's alpha = 0.79. Teamwork climate differed significantly by hospital (F59, 1,911 = 4.06, P < 0.001) and OR caregiver type (F4, 1,911 = 9.96, P < 0.001). Rigorous assessment of teamwork climate is possible using this psychometrically sound teamwork climate scale. This tool and initial benchmarks allow others to compare their teamwork climate to national means, in an effort to focus more on what excellent surgical teams do well.
Zhang, J H; Peng, R; Du, Y; Mou, Y; Li, N N; Cheng, L
2016-11-08
Objective: To evaluate the reliability and validity of Parkinson's disease sleep scale-Chinese version (CPDSS) through a study of a large PD population in southwest China, and to explore the prevalence and characteristics of sleep disorders in Parkinson's disease (PD) patients from southwest China. Methods: A total of 544 PD patients and 220 control subjects were enrolled in our study. Demographic data, CPDSS, ESS, PDQ39, HAMD and H-Y stage were assessed in all subjects. Statistical description, Cronbach's alpha coefficient, intra-class correlation coefficient ( ICC ), Spearman rank correlation coefficient and Mann-Whitney U test were used for statistical analyses. Result: The Cronbach's alpha coefficient for CPDSS was 0.79, ICC of the total scale was 0.94 and ICC of each item ranged from 0.73 to 0.97. The factor analysis yielded a five-factor solution, which explained 63.4% of the total variance. Total and each item scores of CPDSS in PD patients were lower than those in healthy controls. 69.3% of PD patients had sleep disorder, while prevalence in the control group was only 29.6%. Negative correlation was found between CPDSS and ESS. Daytime sleepiness was the most common factor (35.9%) leading to sleep disorders. The sleep disorders of PD patients in Southwest China were significantly related with the course of disease, the severity of disease, the quality of life, depression, cognitive level and motor symptoms. Conclusion: CPDSS has good feasibility, reliability and validity in PD population from southwest China. CPDSS is considered as an effective tool for the assessment of sleep disorder in PD patients.
Cavalcante, Milady Cutrim Vieira; Lamy, Zeni Carvalho; Lamy Filho, Fernando; França, Ana Karina Teixeira da Cunha; dos Santos, Alcione Miranda; Thomaz, Erika Bárbara Abreu Fonseca; da Silva, Antonio Augusto Moura; Salgado Filho, Natalino
2013-01-01
There is a known association between low scores for quality of life (QOL) and higher rates of hospitalization, mortality in hemodialysis vascular access catheter, older age, lack of regular occupation, presence of comorbidities and hypoalbuminemia. There is still no agreement about the influence of sex, educational level, socioeconomic status and treatment time on the worst levels of QOL. Identify socioeconomic, demographic, clinical, nutritional and laboratory factors associated with worse QOL in adults undergoing hemodialysis in Sao Luís, Maranhão, Brazil. A cross-sectional study which evaluated the QOL of patients with chronic renal disease, aged 20-59 years, undergoing hemodialysis. Two instruments were used: the Kidney Disease Quality of Life -Short Form 1.3 (KDQOL-SF™ 1.3) and a questionnaire on socioeconomic, demographic, clinical, nutritional and laboratory data. The reliability of KDQOL-SF™ 1.3 was assessed by Cronbach's alpha. For the multivariable analysis a Poisson regression model with robust adjustment of the standard error was used. The reliability assessment of KDQOL-SF™ 1.3 showed a Cronbach's alpha test greater than 0.8 in all areas. The areas with the worst levels of QOL were "work situation", "burden of kidney disease", "patient satisfaction", "physical function" and "general health". Having less than 8 years of schooling, coming from the countryside and having cardiovascular disease were associated to the areas with the worst levels of QOL. KDQOL-SF™ 1.3 is a reliable instrument to measure quality of life of hemodialysis patients. Demographic and clinical conditions can negatively influence QOL in chronic renal failure patients.
Kobuse, Hiroe; Morishima, Toshitaka; Tanaka, Masayuki; Murakami, Genki; Hirose, Masahiro; Imanaka, Yuichi
2014-06-01
To develop a reliable and valid questionnaire that can distinguish features of organizational culture for patient safety across subgroups such as hospitals, professions, management/non-management positions and units/wards. We developed a Hospital Organizational Culture Questionnaire based on a conceptual framework incorporating items from a review of existing literature. The questionnaire was administered to hospital staff including doctors, nurses, allied health personnel, and administrative staff at six public hospitals in Japan. Reliability and validity were assessed through exploratory factor analysis, multitrait scaling analysis, Cronbach's alpha coefficient and multiple regression analysis using staff-perceived achievement of safety as the response variable. Discriminative power across subgroups was assessed with radar chart profiling. Of the 3304 hospital staff surveyed, 2924 (88.5%) responded. After exploratory factor analysis and multitrait analysis, the finalized questionnaire was composed of 24 items in the following eight dimensions: improvement orientation, passion for mission, professional growth, resource allocation prioritization, inter-sectional collaboration, responsibility and authority, teamwork, and information sharing. Construct validity and internal consistency of dimensions were confirmed with multitrait analysis and Cronbach's alpha coefficients, respectively. Multiple regression analysis showed that improvement orientation, passion for mission, resource allocation prioritization and information sharing were significantly associated with higher achievement in safety practices. Our questionnaire tool was able to distinguish features of safety culture among different subgroups. Our questionnaire demonstrated excellent validity and reliability, and revealed distinct cultural patterns among different subgroups. Quantitative assessment of organizational safety culture with this tool may further the understanding of associated characteristics of each subgroup and provide insight into organizational readiness for patient safety improvement. © 2014 John Wiley & Sons, Ltd.
Moser, Debra K; Riegel, Barbara; McKinley, Sharon; Doering, Lynn V; Meischke, Hendrika; Heo, Seongkum; Lennie, Terry A; Dracup, Kathleen
2009-01-01
Perceived control is a construct with important theoretical and clinical implications for healthcare providers, yet practical application of the construct in research and clinical practice awaits development of an easily administered instrument to measure perceived control with evidence of reliability and validity. To test the psychometric properties of the Control Attitudes Scale-Revised (CAS-R) using a sample of 3,396 individuals with coronary heart disease, 513 patients with acute myocardial infarction, and 146 patients with heart failure. Analyses were done separately in each patient group. Reliability was assessed using Cronbach's alpha to determine internal consistency, and item homogeneity was assessed using item-total and interitem correlations. Validity was examined using principal component analysis and testing hypotheses about known associations. Cronbach's alpha values for the CAS-R in patients with coronary heart disease, acute myocardial infarction, and heart failure were all greater than .70. Item-total and interitem correlation coefficients for all items were acceptable in the groups. In factor analyses, the same single factor was extracted in all groups, and all items were loaded moderately or strongly to the factor in each group. As hypothesized in the final construct validity test, in all groups, patients with higher levels of perceived control had less depression and less anxiety compared with those of patients who had lower levels of perceived control. This study provides evidence of the reliability and validity of the 8-item CAS-R as a measure of perceived control in patients with cardiac illness and provides important insight into a key patient construct.
Dąbrowska, Marta; Krakowiak, Karolina; Radlińska, Olga; Rybka, Aleksandra; Grabczak, Elżbieta M; Maskey-Warzęchowska, Marta; Korczyński, Piotr; Birring, Surinder S; Krenke, Rafał
2016-01-01
The Leicester Cough Questionnaire (LCQ) is one of the few specific quality-of-life questionnaires (QOLQ) dedicated to measuring the impact of chronic cough on patients' health/condition. The aim of the study was to validate the Polish version of the LCQ. The LCQ was translated forward and backward. The Polish version of the LCQ was tested on 35 patients suffering from chronic cough (23 women, median age 60 years, nonor ex-smokers, median cough duration of 23 weeks). Its validity was tested by comparison to a visual analogue scale (VAS) of cough intensity and other health questionnaires (hospital anxiety and depression scale - HADS, Euro-Quality of Life Questionnaire - EQ5D, St. George's Respiratory Questionnaire - SGRQ). The internal reliability of the Polish version of the LCQ was determined using the Cronbach alpha coefficient and its repeatability by the intraclass consistency coefficient. The translation of the LCQ into Polish was accepted by the author of the original LCQ. The Cronbach's alpha coefficient for total LCQ was 0.89, and reached 0.82, 0.86 and 0.78 for the physical, psychological and social domain, respectively. There were significant negative correlations between cough severity measured by VAS, the results of the EQ5D and SGRQ and the Polish version of the LCQ. The intraclass correlation coefficient of the test-retest reliability was significant (0.99). The Polish version of the LCQ has been validated and is a reliable tool to measure the impact of chronic cough on quality of life of patients with chronic cough.
[Validation of the AUDIT test for identifying risk consumption and alcohol use disorders in women].
Pérula de Torres, L A; Fernández-García, J A; Arias-Vega, R; Muriel-Palomino, M; Márquez-Rebollo, E; Ruiz-Moral, R
2005-11-30
To validate the AUDIT test for identifying women with excess alcohol consumption and/or dependency syndrome (DS). Descriptive study to validate a test. Two primary care centres and a county drug-dependency centre. 414 women from 18 to 75 recruited at the clinic. Interventions. Social and personal details were obtained through personal interview, their alcohol consumption was quantified and the AUDIT and MALT questionnaires were filled in. Then the semi-structured SCAN interview was conducted (gold standard; DSM-IV and CIE-10 criteria), and analyses were requested (GGT, GOT, GPT, VCM). 186 patients were given a follow-up appointment three-four weeks later (retest). Intra-observer reliability was evaluated with the Kappa index, internal consistency with Cronbach s alpha, and the validity of criteria with indexes of sensitivity and specificity, predictive values and probability quotients. To evaluate the diagnostic performance of the test and the most effective cut-off point, a ROC analysis was run. 11.4% (95% CI, 8.98-13.81) were diagnosed with alcohol abuse (0.5%) or DS (10.9%). The Kappa coefficients of the AUDIT items ranged between 0.685 and 0.795 (P<.001). Internal reliability, with Cronbach s alpha, was 0.932 (95% CI, 0.921-0.941). Test sensitivity was 89.6% (95% CI,76.11-96.02) and specificity was 95.07% (95% CI, 92.18-96.97). The most effective cut-off point was at 6 points. The AUDIT is a questionnaire with good psycho-measurement properties. It is reliable and valid for the detection of risk consumption and DS in women.
Kateel, Ramya; Augustine, Alfred J; Ullal, Sheetal; Prabhu, Shivananda; Bhat, Rahul; Adhikari, Prabha
2017-12-01
To develop and validate Health Related Quality of Life Questionnaire in Diabetic Foot Ulcer Patients (HRQLQDFU) for Indian scenario. This study was conducted in two phases. First phase was Development of HRQLQDFU which included literature search and expert interview. Second phase was validation of HRQLQDFL which included face validation, content validation and construct validation. Face validation was done by ten diabetic foot ulcer patients, ten practicing nurses and ten care givers. They were asked to read and respond to questionnaire and report any difficulty in understanding the questions. Further they were asked to add any item to the questionnaire which according to them has a significant effect on quality of life. Content validation was done by six subject experts who judged the content relevance of questionnaire with score ranging from zero to four; zero being least relevant and four being most relevant. Content validity index was calculated for each question. Questions having content validity index≥0.8 were selected for the study. Reliability was tested by calculating Cronbach's alpha. In the development phase a questionnaire containing 37 questions with six domains was developed. None of patient had difficulty in understanding questions. After content validation a new questionnaire containing 20 questions was developed. Cronbach's alpha was 0.86 which shows good reliability. The new health related quality of life questionnaire on diabetic foot ulcer patients for an Indian scenario is validated and can be a reliably measure for quality of life in diabetic foot ulcer patients. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.
Reliability and validity of the 12-item WHODAS 2.0 in patients with Kashin-Beck disease.
Younus, Mohammad Imran; Wang, Di-Miao; Yu, Fang-Fang; Fang, Hua; Guo, Xiong
2017-09-01
The purpose of this study was to check the reliability and validity of the 12-item Chinese version of the World Health Organization Disability Assessment Schedule 2.0 (WHODAS 2.0) for the assessment of disability in patients with Kashin-Beck disease (KBD). We recruited 219 patients with KBD from the high-risk KBD area in the Shaanxi province, using stratified multistage random sampling. We assessed each patient using the Chinese version of the 12-item WHODAS 2.0 and the Western Ontario and McMaster Universities Index of Osteoarthritis (WOMAC). Statistical evaluations of the instruments consisted of Cronbach's alpha, intraclass correlation coefficient (ICC), confirmatory factor analysis (CFA), and Pearson's correlation coefficient. Cronbach's alpha and ICC for the six domains ranged from 0.704 to 0.906 and 0.690 to 0.852, respectively. A six-factor structure fits the data well (CFI = 0.967, TLI = 0.944, RMSEA = 0.08). Regarding convergent validity, the four domains of the 12-item WHODAS 2.0 (getting around, self-care, life activity, and participation) showed moderate-to-strong correlation for all three domains of the WOMAC (0.428 < |r| < 0.804). Regarding divergent validity, the two domains of the 12-item WHODAS 2.0 (understanding and communication, and getting along with people) showed weak correlation for the three domains of WOMAC (0.182 < |r| < 0.295). The Chinese version of 12-item WHODAS 2.0 questionnaire is a reliable and valid instrument when administered to KBD patients.
The technological influence on health professionals' care: translation and adaptation of scales1
Almeida, Carlos Manuel Torres; Almeida, Filipe Nuno Alves dos Santos; Escola, Joaquim José Jacinto; Rodrigues, Vitor Manuel Costa Pereira
2016-01-01
Objectives: in this study, two research tools were validated to study the impact of technological influence on health professionals' care practice. Methods: the following methodological steps were taken: bibliographic review, selection of the scales, translation and cultural adaptation and analysis of psychometric properties. Results: the psychometric properties of the scale were assessed based on its application to a sample of 341 individuals (nurses, physicians, final-year nursing and medical students). The validity, reliability and internal consistency were tested. Two scales were found: Caring Attributes Questionnaire (adapted) with a Cronbach's Alpha coefficient of 0.647 and the Technological Influence Questionnaire (adapted) with an Alpha coefficient of 0.777. Conclusions: the scales are easy to apply and reveal reliable psychometric properties, an additional quality as they permit generalized studies on a theme as important as the impact of technological influence in health care. PMID:27143537
Powell-Young, Yolanda M; Spruill, Ida J
2011-12-01
The purpose of this investigation was to examine the reliability and factor structure of the Harter Self-Perception Profile for Adolescents (SPPA) with African-Americans. While the SPPA has demonstrated strong psychometric properties with European-Americans, limited information exists with African-Americans. Three hundred and ten (N = 310) female adolescents, from 14 through 18 years of age, completed the SPPA. Estimations of internal consistency reliability with Cronbach's alpha (alpha), item suitability with Pearson (gamma) correlations, and evaluation of factor structure fit utilizing principle axis extraction with oblimin (oblique) rotation were conducted. When compared with Harter's normative data, psychometric properties of the SPPA varied significantly with the current sample. Findings suggested cautious interpretation of data generated with demographically similar cohorts. Further study is warranted to ascertain the factor structure that is most relevant for use with African-American adolescents.
Valid and Reliable Science Content Assessments for Science Teachers
NASA Astrophysics Data System (ADS)
Tretter, Thomas R.; Brown, Sherri L.; Bush, William S.; Saderholm, Jon C.; Holmes, Vicki-Lynn
2013-03-01
Science teachers' content knowledge is an important influence on student learning, highlighting an ongoing need for programs, and assessments of those programs, designed to support teacher learning of science. Valid and reliable assessments of teacher science knowledge are needed for direct measurement of this crucial variable. This paper describes multiple sources of validity and reliability (Cronbach's alpha greater than 0.8) evidence for physical, life, and earth/space science assessments—part of the Diagnostic Teacher Assessments of Mathematics and Science (DTAMS) project. Validity was strengthened by systematic synthesis of relevant documents, extensive use of external reviewers, and field tests with 900 teachers during assessment development process. Subsequent results from 4,400 teachers, analyzed with Rasch IRT modeling techniques, offer construct and concurrent validity evidence.
Measurement properties of the Human Activity Profile questionnaire in hospitalized patients.
Souza, Daniel C; Wegner, Fernando; Costa, Lucíola C M; Chiavegato, Luciana D; Lunardi, Adriana C
To test the measurement properties (reproducibility, internal consistency, ceiling and floor effects, and construct validity) of the Human Activity Profile (HAP) questionnaire in hospitalized patients. This measurement properties study recruited one-hundred patients hospitalized for less than 48h for clinical or surgical reasons. The HAP was administered at baseline and after 48h in a test-retest design). The International Physical Activity Questionnaire (IPAQ-6) was also administered at baseline, aiming to assess the construct validity. We tested the following measurement properties: reproducibility (reliability assessed by type 2,1 intraclass correlation coefficient (ICC 2,1 )); agreement by the standard error of measurement (SEM) and by the minimum detectable change with 90% confidence (MDC 90 ), internal consistency by Cronbach's alpha, construct validity using a chi-square test, and ceiling and floor effects by calculating the proportion of patients who achieved the minimum or maximum scores. Reliability was excellent with an ICC of 0.99 (95% CI=0.98-0.99). SEM was 1.44 points (1.5% of the total score), the MDD 90 was 3.34 points (3.5% of the total score) and the Cronbach's alpha was 0.93 (alpha if item deleted ranging from 0.94 to 0.94). An association was observed between patients classified by HAP and by IPAQ-6 (χ 2 =3.38; p=0.18). Ceiling or floor effects were not observed. The HAP shows adequate measurement properties for the assessment of the physical activity/inactivity level in hospitalized patients. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.
Sarallah, Shojaei; Sadat, Tavafian Sedigheh; Jamshidi, Ahmad Reza; Joan, Wagner
2016-06-01
Psychometric evaluation design. Psychometric evaluation of a multidisciplinary work-related low back pain predictor questionnaire (MWRLBPPQ) of Iranians patient-care workers based on the social cognitive theory. Healthcare is one of the professions in which work-related musculoskeletal disorders are prevalent. The chronic low back pain experienced by patient caregivers can negatively impact their professional performance, and patient handling in a hospital is the main cause of low back pain in this population. This was a cross-sectional study carried out in Qom, Iran from July 2014 to November 2014. A MWRLBPPQ based on nine concepts of the social cognitive theory and existing literature regarding chronic low back pain was developed. Ten patient-care workers first completed the questionnaire as a pilot test, allowing the ambiguities of the instrument to be resolved. Exploratory factor analysis was used to confirm construct validity. This questionnaire was distributed among 452 patient-care workers in hospitals located in different geographically areas in Qom, Iran. Cronbach's Alpha was calculated to assess reliability. In all, 452 caregivers of patients with mean age of 37.71 (standard deviation=8.3) years participated in the study. An exploratory factor analysis loaded seven concepts of self-efficacy, knowledge, outcome perception, self-control, emotional coping, and self-efficacy in overcoming impediments and challenges in the environment. All concepts were jointly accounted for 50.08% of variance of behavior change. The Cronbach's alpha coefficient showed favorable internal consistency (alpha=0.83), and test-retest of the scale with 2-week intervals indicated an appropriate stability for the MWRLBPPQ. The MWRLBPPQ is a reliable and valid theory-based instrument that can be used to predict factors influencing work-related low back pain among workers who lift and transfer patients in hospitals.
ERIC Educational Resources Information Center
Davenport, Ernest C.; Davison, Mark L.; Liou, Pey-Yan; Love, Quintin U.
2015-01-01
This article uses definitions provided by Cronbach in his seminal paper for coefficient a to show the concepts of reliability, dimensionality, and internal consistency are distinct but interrelated. The article begins with a critique of the definition of reliability and then explores mathematical properties of Cronbach's a. Internal consistency…
The development of form two mathematics i-Think module (Mi-T2)
NASA Astrophysics Data System (ADS)
Yao, Foo Jing; Abdullah, Mohd Faizal Nizam Lee; Tien, Lee Tien
2017-05-01
This study aims to develop a training module i-THINK Mathematics Form Two (Mi-T2) to increase the higher-order thinking skills of students. The Mi-T2 training module was built based on the Sidek Module Development Model (2001). Constructivist learning theory, cognitive learning theory, i-THINK map and higher order thinking skills were the building blocks of the module development. In this study, researcher determined the validity and reliability of Mi-T2 module. The design being used in this study was descriptive study. To determine the needs of Mi-T2 module, questionnaires and literature review were used to collect data. When the need of the module was determined, the module was built and a pilot study was conducted to test the reliability of the Mi-T2 module. The pilot study was conducted at a secondary school in North Kinta, Perak. A Form Two class was selected to be the sample study through clustered random sampling. The pilot study was conducted for two months and one topic had been studied. The Mi-T2 module was evaluated by five expert panels to determine the content validity of the module. The instruments being used in the study were questionnaires about the necessity of the Mi-T2 module for guidance, questionnaires about the validity of the module and questionnaires concerning the reliability of the module. Statistical analysis was conducted to determine the validity and reliability coefficients of the Mi-T2 module. The content validity of Mi-T2 module was determined by Cohen's Kappa's (1968) agreement coefficient and the reliability of Mi-T2 module was determined by Cronbach Alpha's value scale. The content validity of Mi-T2 module was 0.89 and the Cronbach Alpha's value of Mi-T2 module was 0.911.
Cil Akinci, Ayse; Pinar, Rukiye
2014-02-01
To investigate the validity and reliability of the Caregiver Burden Scale in family members who provide primary care for haemodialysis patients. In Turkey, there is a need for a multi-dimensional instrument to evaluate the caregiver burden in people who provide care for patients with chronic diseases. A methodological study. The study sample consisted of 161 family members who provide primary care for haemodialysis patients. The forward-backward translation method was used to develop the Turkish Caregiver Burden Scale. The reliability was based on internal consistency investigated by Cronbach's alpha and item-total correlation. The factorial construct validity of the scale was tested with confirmatory factor analysis. By means of convergent and divergent validity, correlation between Caregiver Burden Scale and 36-Item Short Form Health Survey (SF-36) and correlation between Caregiver Burden Scale and the Maslach Burnout Scale were investigated. Cronbach's alpha and item-total correlations results suggested that there was good internal reliability. We found five underlying factors similar to original Scale's five-factor solution. The confirmatory factor analysis five-factor model represented an acceptable fit. Factor loadings were significant, with standardised loadings ranging from 0·43-0·81. By means of divergent validity, all sub-dimension scores and the total score of the Caregiver Burden Scale were negatively correlated with the SF-36, whereas there was a positive correlation with the emotional exhaustion and depersonalisation subscales of the Maslach Burnout Scale as expected. These results suggest that the Caregiver Burden Scale is a reliable and valid instrument which can be used with confidence in Turkish caregivers for haemodialysis patients to screen caregiver burden. The burden experienced by people who provide care for patients with chronic diseases can be evaluated with the Caregiver Burden Scale. Additionally, the Caregiver Burden Scale can be used in the evaluation of the effectiveness of attempts to decrease caregiver burden. © 2012 Blackwell Publishing Ltd.
Mohammadsalehi, Narges; Mohammadbeigi, Abolfazl; Jadidi, Rahmatollah; Anbari, Zohreh; Ghaderi, Ebrahim; Akbari, Mojtaba
2015-09-01
Reliability and validity are the key concepts in measurement processes. Young internet addiction test (YIAT) is regarded as a valid and reliable questionnaire in English speaking countries for diagnosis of Internet-related behavior disorders. This study aimed at validating the Persian version of YIAT in the Iranian society. A pilot and a cross-sectional study were conducted on 28 and 254 students of Qom University of Medical Sciences, respectively, in order to validate the Persian version of YIAT. Forward and backward translations were conducted to develop a Persian version of the scale. Reliability was measured by test-retest, Cronbach's alpha and interclass correlation coefficient (ICC). Face, content and construct validity were approved by the importance score index, content validity ratio (CVR), content validity index (CVI), correlation matrix and factor analysis. The SPSS software was used for data analysis. The Cronbach's alpha was 0.917 (CI 95%; 0.901 - 0.931). The average of scale-level CVI was calculated to be 0.74; the CVI index for each item was higher than 0.83 and the average of CVI index was equal to 0.89. Factor analysis extracted three factors including personal activities disorder (PAD), emotional and mood disorder (EMD) and social activities disorder (SAD), with more than 55.8% of total variances. The ICC for different factors of Persian version of Young Questionnaire including PAD, EMD and for SAD was r = 0.884; CI 95%; 0.861 - 0.904, r = 0.766; CI 95%; 0.718 - 0.808 and r = 0.745; CI 95%; 0.686 - 0.795, respectively. Our study showed that the Persian version of YIAT is good and usable on Iranian people. The reliability of the instrument was very good. Moreover, the validity of the Persian translated version of the scale was sufficient. In addition, the reliability and validity of the three extracted factors of YIAT were evaluated and were acceptable.
Kaux, Jean-François; Delvaux, François; Schaus, Jean; Demoulin, Christophe; Locquet, Médéa; Buckinx, Fanny; Beaudart, Charlotte; Dardenne, Nadia; Van Beveren, Julien; Croisier, Jean-Louis; Forthomme, Bénédicte; Bruyère, Olivier
Translation and validation of algo-functional questionnaire. The lateral elbow tendinopathy is a common injury in tennis players and physical workers. The Patient-Rated Tennis Elbow Evaluation (PRTEE) Questionnaire was specifically designed to measure pain and functional limitations in patients with lateral epicondylitis (tennis elbow). First developed in English, this questionnaire has since been translated into several languages. The aims of the study were to translate and cross-culturally adapt the PRTEE questionnaire into French and to evaluate the reliability and validity of this translated version of the questionnaire (PRTEE-F). The PRTEE was translated and cross-culturally adapted into French according to international guidelines. To assess the reliability and validity of the PRTEE-F, 115 participants were asked twice to fill in the PRTEE-F, and once the Disabilities of Arm, Shoulder and Hand Questionnaire (DASH) and the Short Form Health Survey (SF-36). Internal consistency (using Cronbach's alpha), test-retest reliability (using intraclass correlation coefficient (ICC), standard error of measurement and minimal detectable change), and convergent and divergent validity (using the Spearman's correlation coefficients respectively with the DASH and with some subscales of the SF-36) were assessed. The PRTEE was translated into French without any problems. PRTEE-F showed a good test-retest reliability for the overall score (ICC 0.86) and for each item (ICC 0.8-0.96) and a high internal consistency (Cronbach's alpha = 0.98). The correlation analyses revealed high correlation coefficients between PRTEE-F and DASH (convergent validity) and, as expected, a low or moderate correlation with the divergent subscales of the SF-36 (discriminant validity). There was no floor or ceiling effect. The PRTEE questionnaire was successfully cross-culturally adapted into French. The PRTEE-F is reliable and valid for evaluating French-speaking patients with lateral elbow tendinopathy. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Sandhu, Sukhvinder Singh; Ismail, Noor Hassim; Rampal, Krishna Gopal
2015-11-01
The Perceived Stress Scale-10 (PSS-10) is widely used to assess stress perception. The aim of this study was to translate the original PSS-10 into Malay and assess the reliability and validity of the Malay version among nurses. The Malay version of the PSS-10 was distributed among 229 nurses from four government hospitals in Selangor State. Test-retest reliability and concurrent validity was conducted with 25 nurses with the Malay version of the Depression Anxiety Stress Scales (DASS) 21. Cronbach's alpha, confirmatory factor analysis (CFA), intraclass correlation coefficient and Pearson's r correlation coefficient were used to determine the psychometric properties of the Malay PSS-10. Two factor components were yielded through exploratory factor analysis with eigenvalues of 3.37 and 2.10, respectively. Both of the factors accounted for 54.6% of the variance. CFA yielded a two-factor structure with satisfactory goodness-of-fit indices [x 2 /df = 2.43; comparative fit index (CFI) = 0.92, goodness-of-fit Index (GFI) = 0.94; standardised root mean square residual (SRMR) = 0.07 and root mean square error of approximation (RMSEA) = 0.08 (90% CI = 0.07-0.09)]. The Cronbach's alpha coefficient for the total items was 0.63 (0.82 for factor 1 and 0.72 for factor 2). The intraclass correlation coefficient (ICC) was 0.81 (95% CI: 0.62-0.91) for test-retest reliability testing after seven days. The total score and the negative component of the PSS-10 correlated significantly with the stress component of the DASS-21: (r = 0.61, P < 0.001) and (r = 0.56, P < 0.004), respectively. The Malay version of the PSS-10 demonstrated a satisfactory level of validity and reliability to assess stress perception. Therefore, this questionnaire is valid in assessing stress perception among nurses in Malaysia.
Validity and reliability of the Persian version of mobile phone addiction scale
Mazaheri, Maryam Amidi; Karbasi, Mojtaba
2014-01-01
Background: With regard to large number of mobile users especially among college students in Iran, addiction to mobile phone is attracting increasing concern. There is an urgent need for reliable and valid instrument to measure this phenomenon. This study examines validity and reliability of the Persian version of mobile phone addiction scale (MPAIS) in college students. Materials and Methods: this methodological study was down in Isfahan University of Medical Sciences. One thousand one hundred and eighty students were selected by convenience sampling. The English version of the MPAI questionnaire was translated into Persian with the approach of Jones et al. (Challenges in language, culture, and modality: Translating English measures into American Sign Language. Nurs Res 2006; 55: 75-81). Its reliability was tested by Cronbach's alpha and its dimensionality validity was evaluated using Pearson correlation coefficients with other measures of mobile phone use and IAT. Construct validity was evaluated using Exploratory subscale analysis. Results: Cronbach's alpha of 0.86 was obtained for total PMPAS, for subscale1 (eight items) was 0.84, for subscale 2 (five items) was 0.81 and for subscale 3 (two items) was 0.77. There were significantly positive correlations between the score of PMPAS and IAT (r = 0.453, P < 0.001) and other measures of mobile phone use. Principal component subscale analysis yielded a three-subscale structure including: inability to control craving; feeling anxious and lost; mood improvement accounted for 60.57% of total variance. The results of discriminate validity showed that all the item's correlations with related subscale were greater than 0.5 and correlations with unrelated subscale were less than 0.5. Conclusion: Considering lack of a valid and reliable questionnaire for measuring addiction to the mobile phone, PMPAS could be a suitable instrument for measuring mobile phone addiction in future research. PMID:24778668
Evaluation of written medicine information: validation of the Consumer Information Rating Form.
Koo, Michelle M; Krass, Ines; Aslani, Parisa
2007-06-01
The Consumer Information Rating Form (CIRF) was developed as a direct method for measuring consumers' perceptions of the comprehensibility, utility, and design quality of written medicine information. The validity and reliability of the CIRF were evaluated in a small convenience consumer sample in the US. Its validity and reliability have yet to be established in a larger sample of consumers who are on chronic therapy in different settings. To determine the validity and reliability of the CIRF in Australian consumers on chronic therapy. Consumers read and subsequently evaluated a Consumer Medicine Information (CMI) leaflet for one of their own medications, using an adapted version of the CIRF. The construct validity and internal reliability of the adapted version of the CIRF were tested using principal components analysis (PCA) and Cronbach's alpha, respectively. The adapted CIRF was completed by 282 consumers (aged 19-90 y; median 66; interquartile range 53-75 y; 60.3% females). Most respondents spoke primarily English at home (85.5%), had attained at least secondary education (84%), and had adequate health literacy levels (88.2%). Consumers rated CMI easy to read, understand, and navigate, but less easy to remember and keep. Most also found it to be useful and to contain the right amount of information. The design aspects also scored favorably, although CMI did score relatively poorly in terms of its attractiveness and tone (whether alarming or not). PCA yielded 3 factors (explaining 59.3% of the total variance) identical to those in the original CIRF: comprehensibility, utility, and design quality. All factors demonstrated good reliability (Cronbach's alpha 0.74, 0.92, and 0.75, respectively). The CIRF appears to be a robust instrument for assessing consumers' perceptions of written medicine information. However, validity always needs to be reestablished when using a previously validated measure in a different population.
Medeiros, Lydia C; Hillers, Virginia N; Chen, Gang; Bergmann, Verna; Kendall, Patricia; Schroeder, Mary
2004-11-01
The objective of this study was to design and develop food safety knowledge and attitude scales based on food-handling guidelines developed by a national panel of food safety experts. Knowledge (n=43) and attitude (n=49) questions were developed and pilot-tested with a variety of consumer groups. Final questions were selected based on item analysis and on validity and reliability statistical tests. Knowledge questions were tested in Washington State with participants in low-income nutrition education programs (pretest/posttest n=58, test/retest n=19) and college students (pretest/posttest n=34). Attitude questions were tested in Ohio with nutrition education program participants (n=30) and college students (non-nutrition majors n=138, nutrition majors n=57). Item analysis, paired sample t tests, Pearson's correlation coefficients, and Cronbach's alpha were used. Reliability and validity tests of individual items and the question sets were used to reduce the scales to 18 knowledge questions and 10 attitude questions. The knowledge and attitude scales covered topics ranked as important by a national panel of experts and met most validity and reliability standards. The 18-item knowledge questionnaire had instructional sensitivity (mean score increase of more than three points after instruction), internal reliability (Cronbach's alpha >.75), and produced similar results in test-retest without intervention (coefficient of stability=.81). Knowledge of correct procedures for hand washing and avoiding cross-contamination was widespread before instruction. Knowledge was limited regarding avoiding food preparation while ill, cooking hamburgers, high-risk foods, and whether cooked rice and potatoes could be stored at room temperature. The 10-item attitude scale had an appropriate range of responses (item difficulty) and produced similar results in test-retest ( P =.01). Internal consistency ranged from alpha=.63 to .89. Students anticipating a career where food safety is valued had higher attitude scale scores than participants of extension education programs. Uses for the knowledge questionnaire include assessment of subject matter knowledge before instruction and knowledge gain after instruction. The attitude scale assesses an outcome variable that may predict food safety behavior.
Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de
2017-12-08
The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.
Kwok, Cannas; Endrawes, Gihane; Lee, Chun Fan
2016-02-01
The aim of the study was to report the psychometric properties of the Arabic version of the Breast Cancer Screening Beliefs Questionnaire (BCSBQ). A convenience sample of 251 Arabic-Australian women was recruited from a number of Arabic community organizations. Construct validity was examined by Cuzick's non-parametric test while Cronbach α was used to assess internal consistency reliability. Explanatory factor analysis was conducted to study the factor structure. The results indicated that the Arabic version of the BCSBQ had satisfactory validity and internal consistency. The Cronbach's alpha of the three subscales ranged between 0.810 and 0.93. The frequency of breast cancer screening practices (breast awareness, clinical breast-examination and mammography) were significantly associated with attitudes towards general health check-up and perceived barriers to mammographic screening. Exploratory factor analysis showed a similar fit for the hypothesized three-factor structure with our data set. The Arabic version of the BCBSQ is a culturally appropriate, valid and reliable instrument for assessing the beliefs, knowledge and attitudes to breast cancer and breast cancer screening practices among Arabic-Australian women. Copyright © 2015 Elsevier Ltd. All rights reserved.
Shariat, Ardalan; Tamrin, Shamsul Bahri Mohd; Arumugam, Manohar; Ramasamy, Rajesh
2016-03-09
The Cornell Musculoskeletal Discomfort Questionnaire (CMDQ) was developed to assess the level of musculoskeletal discomfort among office workers related to their ergonomic situation. The primary objective of this initial study is to analyze the validity and dependability of the Malay translation of the Cornell Musculoskeletal Discomfort Questionnaire. The questionnaire was self-administered two times, with an interval of two weeks in order to evaluate the accuracy of the original findings with a retest. The study involved 115 participants. The range of Cronbach Alpha coefficient showed a considerable consistency of the items for each sub-scale (Cronbach's a > 0.95). The range of Kappa coefficients was between (ICC = 0.690-0.949, p < 0.001), (ICC = 0.801-0.979, p < 0.001) and (ICC = 0.778-0.944, p < 0.001) for frequency, severity and interference scales. This research, introduced the Malay-language version of the CMDQ (CMDQ-M) as the first formal validation of the CMDQ, and confirmed a high reliability and validity for the evaluation of musculoskeletal discomfort among the study population.
Dougherty, Cynthia M.; Johnston, Sandra K.; Thompson, Elaine Adams
2009-01-01
The purpose of this study was to assess the reliability and validity characteristics of two new scales that measure self-efficacy expectations (SE-ICD) and outcome expectations (OE-ICD) in survivors (n=168) of sudden cardiac arrest (SCA), all of whom received an implantable cardioverter defibrillator (ICD). Cronbach's alpha reliability demonstrated good internal consistency (SE-ICD α = 0.93 and OE-ICD α = 0.81). Correlations with other self-efficacy instruments (general self-efficacy and social self-efficacy) were consistently high. The instruments were responsive to change across time with effect sizes of 0.46 for SE-ICD, and 0.26 for OE-ICD. These reliable, valid, and responsive instruments for measurement of self-efficacy expectations and outcome expectations after an ICD can be used in research and clinical settings. PMID:17693214
Vasconcelos-Raposo, José; Fernandes, Helder Miguel; Teixeira, Carla M
2013-01-01
The purpose of the present study was to assess the factor structure and reliability of the Depression, Anxiety and Stress Scales (DASS-21) in a large Portuguese community sample. Participants were 1020 adults (585 women and 435 men), with a mean age of 36.74 (SD = 11.90) years. All scales revealed good reliability, with Cronbach's alpha values between .80 (anxiety) and .84 (depression). The internal consistency of the total score was .92. Confirmatory factor analysis revealed that the best-fitting model (*CFI = .940, *RMSEA = .038) consisted of a latent component of general psychological distress (or negative affectivity) plus orthogonal depression, anxiety and stress factors. The Portuguese version of the DASS-21 showed good psychometric properties (factorial validity and reliability) and thus can be used as a reliable and valid instrument for measuring depression, anxiety and stress symptoms.
Verification of reliability and validity of a Japanese version of the Rathus Assertiveness Schedule.
Suzuki, Eiko; Kanoya, Yuka; Katsuki, Takeshi; Sato, Chifumi
2007-07-01
To verify the reliability and validity of a Japanese version of the Rathus Assertiveness Schedule in novice nurses to contribute to nursing management. An adequate scale is needed to measure the assertiveness and the effect of assertion training for Japanese nurses and to compare them with those in other countries. Rathus Assertiveness Schedule was adapted to Japanese with back-translation and its validity was examined in 989 novice nurses. The Japanese version showed a high coefficient of reliability in a split-half reliability test (r=0.76; P<0.01). The coefficient of reliability of Cronbach's alpha was high (r=0.84; P<0.01) indicating high internal consistency. The similarity with the concept of stress coping was shown. We extracted eight principal factors using factor analysis with varimax rotation. Elements of these factors were similar to those of the original Rathus Assertiveness Schedule. The Japanese version of Rathus Assertiveness Schedule was verified.
Negahban, Hossein; Mohtasebi, Elham; Goharpey, Shahin
2015-01-01
The aim of this methodological study was to cross-culturally translate the Shoulder Activity Scale (SAS) into the Persian and determine its clinimetric properties including reliability, validity, and responsiveness in patients with shoulder disorders. Persian version of the SAS was obtained after standard forward-backward translation. Three questionnaires were completed by the respondents: SAS, shoulder pain and disability index (SPADI), and Short-Form 36 Health Survey (SF-36). The patients completed the SAS, 1 week after the first visit to evaluate the test-retest reliability. Construct validity was evaluated by examining the associations between the scores on the SAS and the scores obtained from the SPADI, SF-36, and age of the patients. To assess responsiveness, data were collected in the first visit and then again after 4 weeks physiotherapy intervention. Test-retest reliability and internal consistency were assessed using Intra-class Correlation Coefficient (ICC) and Cronbach's alpha, respectively. To evaluate construct validity, Spearman's rank correlation was used. The ability of the SAS to detect changes was evaluated by the receiver-operating characteristics method. No problem or language difficulties were reported during translation process. Test-retest reliability of the SAS was excellent with an ICC of 0.98. Also, the marginal Cronbach's alpha level of 0.64 was obtained. The correlation between the SAS and the SPADI was low, proving divergent validity, whereas the correlations between the SAS and the SF-36/age were moderate proving convergent validity. A marginally acceptable responsiveness was achieved for the Persian SAS. The study provides some evidences to support the test-retest reliability, internal consistency, construct validity, and responsiveness of the Persian version of the SAS in patients with shoulder disorders. Therefore, it seems that this instrument is a useful measure of shoulder activity level in research setting and clinical practice. The shoulder activity scale (SAS) is a reliable, valid, and responsive measure of shoulder activity level in Persian-speaking patients with different shoulder disorders. The results on clinimetric properties of the Persian SAS are comparable with its original, English version. Persian version of the SAS can be used in "clinical" and "research" settings of patients with shoulder disorders.
Koontz, Michaela B; Cuttler, Leona; Palmert, Mark R; O'Riordan, Maryann; Borawski, Elaine A; McConnell, Judy; Kern, Elizabeth O
2010-03-01
OBJECTIVE The American Diabetes Association advocates insulin regimens for youth with type 1 diabetes that involve adjusting insulin dose based on carbohydrate intake and blood glucose level. Implementing these regimens requires knowledge about carbohydrate content of foods and subsequent calculations of insulin dose, skills that may be difficult to gauge in practice. Therefore, we sought to develop and validate a questionnaire, the PedCarbQuiz (PCQ), to assess carbohydrate and insulin-dosing knowledge in youth with type 1 diabetes. RESEARCH DESIGN AND METHODS After development by an expert panel, the PCQ was administered to 75 youth with type 1 diabetes or their parents. Reliability was assessed by Cronbach alpha and split-half testing. To assess validity, scores were correlated with A1C, expert assessments, parent educational level, and complexity of insulin regimen. RESULTS PCQ mean score was 87 +/- 9.7% (range 42-98%). Cronbach alpha was 0.88, and correlation of split halves was 0.59 (P < 0.0001). Higher PCQ scores correlated significantly with lower A1C (r = -0.29, P = 0.01) and expert assessments (r = 0.56, P < 0.001). Scores were significantly higher in parents with college degrees than in those without (P = 0.01) and in participants with more complex insulin regimens (P = 0.003). CONCLUSIONS The PCQ is a novel, easily administered instrument to assess knowledge about carbohydrates and insulin dosing calculations. Initial analyses support the reliability and validity of the PCQ.
Dykes, Patricia C; Hurley, Ann; Cashen, Margaret; Bakken, Suzanne; Duffy, Mary E
2007-01-01
The use of health information technology (HIT) for the support of communication processes and data and information access in acute care settings is a relatively new phenomenon. A means of evaluating the impact of HIT in hospital settings is needed. The purpose of this research was to design and psychometrically evaluate the Impact of Health Information Technology scale (I-HIT). I-HIT was designed to measure the perception of nurses regarding the ways in which HIT influences interdisciplinary communication and workflow patterns and nurses' satisfaction with HIT applications and tools. Content for a 43-item tool was derived from the literature, and supported theoretically by the Coiera model and by nurse informaticists. Internal consistency reliability analysis using Cronbach's alpha was conducted on the 43-item scale to initiate the item reduction process. Items with an item total correlation of less than 0.35 were removed, leaving a total of 29 items. Item analysis, exploratory principal component analysis and internal consistency reliability using Cronbach's alpha were used to confirm the 29-item scale. Principal components analysis with Varimax rotation produced a four-factor solution that explained 58.5% of total variance (general advantages, information tools to support information needs, information tools to support communication needs, and workflow implications). Internal consistency of the total scale was 0.95 and ranged from 0.80-0.89 for four subscales. I-HIT demonstrated psychometric adequacy and is recommended to measure the impact of HIT on nursing practice in acute care settings.
Park, Young Il
2016-01-01
BACKGROUND/OBJECTIVES This research analyzes the effects of the food choices of industrial workers according to their sugar intake pattern on their job satisfaction through the construction of a model on the relationship between sugar intake pattern and job satisfaction. SUBJECTS/METHODS Surveys were collected from May to July 2015. A statistical analysis of the 775 surveys from Kyungsangnam-do was conducted using SPSS13.0 for Windows and SEM was performed using the AMOS 5.0 statistics package. RESULTS The reliability of the data was confirmed by an exploratory factor analysis through a Cronbach's alpha coefficient, and the measurement model was proven to be appropriate by a confirmatory factor analysis in conjunction with AMOS. The results of factor analysis on food choice, sugar intake pattern and job satisfaction were categorized into five categories. The reliability of these findings was supported by a Cronbach's alpha coefficient of 0.6 and higher for all factors except confection (0.516) and dairy products (0.570). The multicollinearity results did not indicate a problem between the variables since the highest correlation coefficient was 0.494 (P < 0.01). In an attempt to study the sugar intake pattern in accordance with the food choices and job satisfaction of industrial workers, a structural equation model was constructed and analyzed. CONCLUSIONS All tests confirmed that the model satisfied the recommended levels for the goodness of fit index, and thus, the overall research model was proven to be appropriate. PMID:27478555
Orlandi, Aline; Brumini, Christine; Jones, Anamaria; Natour, Jamil
2016-09-26
Ankylosing spondylitis (AS) generates inflammation and pain in entheses, peripheral joints and the spine. Education regarding AS can improve patients' disability. Thus, it is important to assess patients' knowledge. There is no instrument in the literature for assessing knowledge of AS in Portuguese. The aim here was to translate to the Brazilian Portuguese language, culturally adapt and test the reliability of the questionnaire "Ankylosing Spondylitis: What do you know?" and to correlate the findings with other factors. Original article regarding validation of questionnaire, produced at the Federal University of Sao Paulo (Unifesp). For translation and cultural adaptation, Guilleman methodology was used. After the first phase, the reliability was tested on 30 patients. Correlations between these scores and other factors were examined. In the interobserver assessment, the Pearson correlation coefficient and Cronbach's alpha were 0.831 and 0.895, respectively. In the intraobserver evaluation, the intraclass correlation coefficient and Cronbach's alpha were 0.79 and 0.883, respectively. At this stage, the score for area of knowledge A showed correlations with ethnicity and education; the score for area D, with age; the total score and scores for areas A and B with "social aspects" of SF-36; and the score for area D with "pain", "vitality" and "emotional aspects" of SF-36. The Brazilian version of the questionnaire "Ankylosing Spondylitis: What do you know?" was created. It is reproducible and correlates with education level, ethnicity and the SF-36 domains "social aspects" and "emotional aspects".
Patel, Vanash M.; Ashrafian, Hutan; Almoudaris, Alex; Makanjuola, Jonathan; Bucciarelli-Ducci, Chiara; Darzi, Ara; Athanasiou, Thanos
2013-01-01
Objectives To compare H index scores for healthcare researchers returned by Google Scholar, Web of Science and Scopus databases, and to assess whether a researcher's age, country of institutional affiliation and physician status influences calculations. Subjects and Methods One hundred and ninety-five Nobel laureates in Physiology and Medicine from 1901 to 2009 were considered. Year of first and last publications, total publications and citation counts, and the H index for each laureate were calculated from each database. Cronbach's alpha statistics was used to measure the reliability of H index scores between the databases. Laureate characteristic influence on the H index was analysed using linear regression. Results There was no concordance between the databases when considering the number of publications and citations count per laureate. The H index was the most reliably calculated bibliometric across the three databases (Cronbach's alpha = 0.900). All databases returned significantly higher H index scores for younger laureates (p < 0.0001). Google Scholar and Web of Science returned significantly higher H index for physician laureates (p = 0.025 and p = 0.029, respectively). Country of institutional affiliation did not influence the H index in any database. Conclusion The H index appeared to be the most consistently calculated bibliometric between the databases for Nobel laureates in Physiology and Medicine. Researcher-specific characteristics constituted an important component of objective research assessment. The findings of this study call to question the choice of current and future academic performance databases. PMID:22964880
Vyas, Shaleen; Nagarajappa, Sandesh; Dasar, Pralhad L.; Mishra, Prashant
2018-01-01
AIM: To translate OHIP-14 into Hindi and test its psychometric properties among school teacher community. METHODS: The OHIP-14 was translated to OHIP-14-H using WHO recommended translation protocol. During pre-testing, an expert panel assessed content validity of the questionnaire. Face validity was assessed on a sample of 10 individuals. The OHIP-14-H was administered on a random sample of 170 primary school teachers. Internal consistency and test-retest reliability were assessed using Cronbach's alpha and Intra-class correlation coefficient (ICC) respectively, with 2 weeks interval. Predictive validity was tested by comparing OHIP-14-H scores with clinical parameters. The concurrent validity was assessed using self-reported oral health and discriminant validity was ascertained through negative association with sociodemographic variables. RESULTS: The mean OHIP-14-H score was 9.57 (S.D = 4.58). ICC and Cronbach's alpha for OHIP-14-H was 0.96 and 0.92 respectively. Concurrent validity using binomial regression model indicated that good (OR = 0.56, 95% CI = 0.55 – 4.47) and moderate (OR = 0.25, 95% CI = 0.17 – 1.87) OHIP-14-H scores were negative but significant risk indicators of poor self reported oral health (P < 0.009). Significant predictive validity was observed between OHIP-14-H scores and clinical parameters (P < 0.000). CONCLUSION: Translated and culturally adapted OHIP-14-H indicates good reliability and validity among primary school teachers. PMID:29417064
Doubova, Svetlana V; Aguirre-Hernandez, Rebeca; Infante-Castañeda, Claudia; Martinez-Vega, Ingrid; Pérez-Cuevas, Ricardo
2015-10-01
The purpose of this study was to validate the Mexican version of the Support Person Unmet Needs Survey (SPUNS-SFM). A cross-sectional survey that included 826 primary caregivers of cancer patients was conducted from June to December 2013 at the Oncology Hospital of the Mexican Institute of Social Security in Mexico City. The validation procedure comprised (1) content validity through a group of experts; (2) construct validity through an exploratory factor analysis based on the polychoric correlation matrix; (3) internal consistency using Cronbach's alpha; (4) convergent validity between SPUNS-SFM and quality of life, anxiety-and-depression scales by calculating Spearman's rank correlation coefficient;( 5) discriminative validity through the Wilcoxon rank-sum test; and (6) test-retest reliability using intraclass correlation coefficient. SPUNS-SFM has 23 items with six factors accounting for 65 % of the total variance. The domains were concerns about the future, access and continuity of healthcare, information, work and finance, and personal and emotional needs. Cronbach's alpha values ranged from 0.70 to 0.88 among factors. SPUNS-SFM had moderate convergent validity compared with quality of life and depression-and-anxiety scales and good discriminative validity, revealing high needs for younger caregivers and more emotional needs for caregivers of patients with advanced cancer stages. Intraclass correlation coefficient between SPUNS-SFM measurements was 0.78. SPUNS-SFM is a valid and reliable tool to identify needs of caregivers of cancer patients.
Pype, Peter; Deveugele, Myriam
2016-12-01
Interprofessional education and collaborative practice are gradually gaining importance in the context of growing healthcare complexity. The readiness for interprofessional learning scale (RIPLS) is a well-known scale that can identify attitudinal barriers and variance across professions, which may affect educational interventions. This study aims to translate the English RIPLS into Dutch and to test its reliability and validity. The scale was translated and back-translated by two pairs of people independently and tested for feasibility and comprehensibility. The translated scale was used with 219 general practitioners, 238 community nurses, and 53 palliative home-care nurses. Exploratory factor analysis was used to assess construct validity. Confirmatory factor analysis was done to generate a fit model. Cronbach's alpha was computed to evaluate internal consistency. Regression analysis was used to evaluate the effect of the RIPLS score on the level of learning through collaboration and to gauge the influence of the participants' gender, age, previous palliative care education, type of practice and years in practice. Confirmatory and exploratory factor analysis confirms the factor structure of the original version. The Dutch version shows good reliability (overall Cronbach's alpha: 0.88; intraclass correlation coefficient after test-retest: 0.718 (95%CI: 0.499-0.852). The RIPLS score correlates with the amount of workplace learning during collaboration (discriminant validity: P < 0.001). The Dutch translation of the RIPLS is now ready for comparative studies.
[Development of MEDUC-PG14 survey to assess postgraduate teaching in medical specialties].
Pizarro, Margarita; Solís, Nancy; Rojas, Viviana; Díaz, Luis Antonio; Padilla, Oslando; Letelier, Luz María; Aizman, Andrés; Sarfatis, Alberto; Olivos, Trinidad; Soza, Alejandro; Delfino, Alejandro; Latorre, Gonzalo; Ivanovic-Zuvic, Danisa; Hoyl, Trinidad; Bitran, Marcela; Arab, Juan Pablo; Riquelme, Arnoldo
2015-08-01
Feedback is one of the most important tools to improve teaching in medical education. To develop an instrument to assess the performance of clinical postgraduate teachers in medical specialties. A qualitative methodology consisting in interviews and focus-groups followed by a quantitative methodology to generate consensus, was employed. After generating the instrument, psychometric tests were performed to assess the construct validity (factor analysis) and reliability (Cronbachs alpha). Experts in medical education, teachers and residents of a medical school participated in interviews and focus groups. With this information, 26 categories (79 items) were proposed and reduced to 14 items (Likert scale 1-5) by an experts Delphi panel, generating the MEDUC-PG14 survey, which was answered by 123 residents from different programs of medical specialties. Construct validity was carried out. Factor analysis showed three domains: Teaching and evaluation, respectful behavior towards patients and health care team, and providing feedback. The global score was 4.46 ± 0.94 (89% of the maximum). One teachers strength, as evaluated by their residents was respectful behavior with 4.85 ± 0.42 (97% of the maximum). Providing feedback obtained 4.09 ± 1.0 points (81.8% of the maximum). MEDUC-PG14 survey had a Cronbachs alpha coefficient of 0.947. MEDUC-PG14 survey is a useful and reliable guide for teacher evaluation in medical specialty programs. Also provides feedback to improve educational skills of postgraduate clinical teachers.
Dockins, James; Abuzahrieh, Ramzi; Stack, Martin
2015-01-01
To translate and adapt an effective, validated, benchmarked, and widely used patient satisfaction measurement tool for use with an Arabic-speaking population. Translation of survey's items, survey administration process development, evaluation of reliability, and international benchmarking Three hundred-bed tertiary care hospital in Jeddah, Saudi Arabia. 645 patients discharged during 2011 from the hospital's inpatient care units. INTERVENTIONS; The Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) instrument was translated into Arabic, a randomized weekly sample of patients was selected, and the survey was administered via telephone during 2011 to patients or their relatives. Scores were compiled for each of the HCAHPS questions and then for each of the six HCAHPS clinical composites, two non-clinical items, and two global items. Clinical composite scores, as well as the two non-clinical and two global items were analyzed for the 645 respondents. Clinical composites were analyzed using Spearman's correlation coefficient and Cronbach's alpha to demonstrate acceptable internal consistency for these items and scales demonstrated acceptable internal consistency for the clinical composites. (Spearman's correlation coefficient = 0.327 - 0.750, P < 0.01; Cronbach's alpha = 0.516 - 0.851) All ten HCAHPS measures were compared quarterly to US national averages with results that closely paralleled the US benchmarks. . The Arabic translation and adaptation of the HCAHPS is a valid, reliable, and feasible tool for evaluation and benchmarking of inpatient satisfaction in Arabic speaking populations.
[Translation and validation in italian of the Moral Distress Scale for psychiatric nurses (MDS-P)].
Canciani, Eleonora; Spotti, Daniela; Bonetti, Loris
2016-01-01
Moral distress (MD) is a painful feeling and/or psychological disequilibrium, which may lead to negative consequences into the wellness of a nurse's working life. Nurses who work in psychiatry are more likely to experience a different type of MD compared with nurses of other contexts. In Italy a tool to evaluate MD in nurses who work in psychiatry doesn't exist. The aim of this study is to validate the Moral Distress Scale for Psychiatric Nurses (MDS-P) in Italian language. For translation the forward and back-translation has been used; the effectiveness regarding content and face validity of the translated scale has been analyzed through a focus group with experts of the field. In order to check the reliability of the scale the test-retest method has been used, by means of the determination of Spearman's correlation coefficient, Intraclass Correlation Coefficient (ICC) and Cronbach's alpha. The forward and back-translation process was successful. During the focus group analysis, 8 items were added to the 15 items of the original scale, due to experts suggestions. 32 nurses took part in the test-retest phase. Spearman's correlation coefficient resulted to be 0,91, ICC > 0,9, Cronbach's alpha calculated on test and retest, was always >0,9. The Italian version of the MDS-P proves to be an effective, appropriate and reliable instrument to measure the MD phenomenon within the population of nurses who work in the psychia- tric field in Italy.
Vallès, Jordi; Guilera, Magda; Briones, Zahara; Gomar, Carmen; Canet, Jaume; Alonso, Jordi
2010-05-01
Health-related quality of life is usually reported for specific rather than heterogeneous populations such as those treated in routine anesthesia practice. The 8-item short-form generic health-related quality-of-life questionnaire (SF-8) is a candidate instrument for this setting. The authors evaluated the feasibility, reliability, validity, and responsiveness to change of the Spanish version of SF-8 in a population-based surgical cohort. Recruiting patients from a large population-based study of risk factors for pulmonary complications, before surgery, the authors administered the 1-week recall SF-8 to 2,991 patients undergoing nonobstetric elective or emergency surgery in 59 hospitals, each of which collected data on seven randomly assigned days in 2006. The SF-8 was administered again 3 months later. Reliability was evaluated using the Cronbach alpha coefficient and validity by comparing physical and mental component summary SF-8 scores with clinical variables. Responsiveness after surgery was evaluated using the standardized response mean. Cronbach alpha for the overall test was 0.92. Physical and mental component summary scores and all individual scores were lower (worse quality of life) in women (P < 0. 01) and decreased with age (P < 0.01). Preoperative scores were lower for those in worse clinical condition (higher body mass index, American Society of Anesthesiologists physical status class, or surgical risk scores), with preoperative respiratory symptoms, and in emergency situations (P < 0.01). The standardized response mean ranged from 0.1 to 0.5. The SF-8 is a feasible, reliable, valid, and responsive instrument for assessing health-related quality of life in a broad-spectrum surgical population.
Ando, Yukako; Kataoka, Tsuyoshi; Okamura, Hitoshi; Tanaka, Katsutoshi; Kobayashi, Toshio
2013-12-01
The purpose of this research is to verify the reliability and validity of a job stressor scale for nurses caring for patients with intractable neurological diseases. A mail survey was conducted using a self-report questionnaire. The subjects were 263 nurses and assistant nurses working in wards specializing in intractable neurological diseases. The response rate was 71.9% (valid response rate, 66.2%). With regard to reliability, internal consistency and stability were assessed. Internal consistency was examined via Cronbach's alpha. For stability, the test-retest method was performed and stability was examined via intraclass correlation coefficients. With regard to validity, factor validity, criterion-related validity, and content validity were assessed. Exploratory factor analysis was used for factor validity. For criterion-related validity, an existing scale was used as an external criterion; concurrent validity was examined via Spearman's rank correlation coefficients. As a result of analysis, there were 26 items in the scale created with an eight factor structure. Cronbach's a for the 26 items was 0.90; with the exception of two factors, alpha for all of the individual sub-factors was high at 0.7 or higher. The intraclass correlation coefficient for the 26 items was 0.89 (p < 0.001). With regard to criterion-related validity, concurrent validity was confirmed and the correlation coefficient with an external criterion was 0.73 (p < 0.001). For content validity, subjects who responded that "The questionnaire represents a stressor well or to a degree" accounted for 81% of the total responses. Reliability and validity were confirmed, so the scale created in the current research is a usable scale.
Vaughan, Brett
2018-01-01
Clinical teaching evaluations are common in health profession education programs to ensure students are receiving a quality clinical education experience. Questionnaires students use to evaluate their clinical teachers have been developed in professions such as medicine and nursing. The development of a questionnaire that is specifically for the osteopathy on-campus, student-led clinic environment is warranted. Previous work developed the 30-item Osteopathy Clinical Teaching Questionnaire. The current study utilised Rasch analysis to investigate the construct validity of the Osteopathy Clinical Teaching Questionnaire and provide evidence for the validity argument through fit to the Rasch model. Senior osteopathy students at four institutions in Australia, New Zealand and the United Kingdom rated their clinical teachers using the Osteopathy Clinical Teaching Questionnaire. Three hundred and ninety-nine valid responses were received and the data were evaluated for fit to the Rasch model. Reliability estimations (Cronbach's alpha and McDonald's omega) were also evaluated for the final model. The initial analysis demonstrated the data did not fit the Rasch model. Accordingly, modifications to the questionnaire were made including removing items, removing person responses, and rescoring one item. The final model contained 12 items and fit to the Rasch model was adequate. Support for unidimensionality was demonstrated through both the Principal Components Analysis/t-test, and the Cronbach's alpha and McDonald's omega reliability estimates. Analysis of the questionnaire using McDonald's omega hierarchical supported a general factor (quality of clinical teaching in osteopathy). The evidence for unidimensionality and the presence of a general factor support the calculation of a total score for the questionnaire as a sufficient statistic. Further work is now required to investigate the reliability of the 12-item Osteopathy Clinical Teaching Questionnaire to provide evidence for the validity argument.
Shioda, Ai; Tadaka, Etsuko; Okochi, Ayako
2017-01-01
Community integration is an essential right for people with schizophrenia that affects their well-being and quality of life, but no valid instrument exists to measure it in Japan. The aim of the present study is to develop and evaluate the reliability and validity of the Japanese version of the Community Integration Measure (CIM) for people with schizophrenia. The Japanese version of the CIM was developed as a self-administered questionnaire based on the original version of the CIM, which was developed by McColl et al. This study of the Japanese CIM had a cross-sectional design. Construct validity was determined using a confirmatory factor analysis (CFA) and data from 291 community-dwelling people with schizophrenia in Japan. Internal consistency was calculated using Cronbach's alpha. The Lubben Social Network Scale (LSNS-6), the Rosenberg Self-Esteem Scale (RSE) and the UCLA Loneliness Scale, version 3 (UCLALS) were administered to assess the criterion-related validity of the Japanese version of the CIM. The participants were 263 people with schizophrenia who provided valid responses. The Cronbach's alpha was 0.87, and CFA identified one domain with ten items that demonstrated the following values: goodness of fit index = 0.924, adjusted goodness of fit index = 0.881, comparative fit index = 0.925, and root mean square error of approximation = 0.085. The correlation coefficients were 0.43 (p < 0.001) with the LSNS-6, 0.42 (p < 0.001) with the RSE, and -0.57 (p < 0.001) with the UCLALS. The Japanese version of the CIM demonstrated adequate reliability and validity for assessing community integration for people with schizophrenia in Japan.
Reliability of a visual scoring system with fluorescent tracers to assess dermal pesticide exposure.
Aragon, Aurora; Blanco, Luis; Lopez, Lylliam; Liden, Carola; Nise, Gun; Wesseling, Catharina
2004-10-01
We modified Fenske's semi-quantitative 'visual scoring system' of fluorescent tracer deposited on the skin of pesticide applicators and evaluated its reproducibility in the Nicaraguan setting. The body surface of 33 farmers, divided into 31 segments, was videotaped in the field after spraying with a pesticide solution containing a fluorescent tracer. A portable UV lamp was used for illumination in a foldaway dark room. The videos of five farmers were randomly selected. The scoring was based on a matrix with extension of fluorescent patterns (scale 0-5) on the ordinate and intensity (scale 0-5) on the abscissa, with the product of these two ranks as the final score for each body segment (0-25). Five medical students rated and evaluated the quality of 155 video images having undergone 4 h of training. Cronbach alpha coefficients and two-way random effects intraclass correlation coefficients (ICC) with absolute agreement were computed to assess inter-rater reliability. Consistency was high (Cronbach alpha = 0.96), but the scores differed substantially between raters. The overall ICC was satisfactory [0.75; 95% confidence interval (CI) = 0.62-0.83], but it was lower for intensity (0.54; 95% CI = 0.40-0.66) and higher for extension (0.80; 95% CI = 0.71-0.86). ICCs were lowest for images with low scores and evaluated as low quality, and highest for images with high scores and high quality. Inter-rater reliability coefficients indicate repeatability of the scoring system. However, field conditions for recording fluorescence should be improved to achieve higher quality images, and training should emphasize a better mechanism for the reading of body areas with low contamination.
Parr, Jeremy R; De Jonge, Maretha V; Wallace, Simon; Pickles, Andrew; Rutter, Michael L; Le Couteur, Ann S; van Engeland, Herman; Wittemeyer, Kerstin; McConachie, Helen; Roge, Bernadette; Mantoulan, Carine; Pedersen, Lennart; Isager, Torben; Poustka, Fritz; Bolte, Sven; Bolton, Patrick; Weisblatt, Emma; Green, Jonathan; Papanikolaou, Katerina; Baird, Gillian; Bailey, Anthony J
2015-10-01
Clinical genetic studies confirm the broader autism phenotype (BAP) in some relatives of individuals with autism, but there are few standardized assessment measures. We developed three BAP measures (informant interview, self-report interview, and impression of interviewee observational scale) and describe the development strategy and findings from the interviews. International Molecular Genetic Study of Autism Consortium data were collected from families containing at least two individuals with autism. Comparison of the informant and self-report interviews was restricted to samples in which the interviews were undertaken by different researchers from that site (251 UK informants, 119 from the Netherlands). Researchers produced vignettes that were rated blind by others. Retest reliability was assessed in 45 participants. Agreement between live scoring and vignette ratings was very high. Retest stability for the interviews was high. Factor analysis indicated a first factor comprising social-communication items and rigidity (but not other repetitive domain items), and a second factor comprised mainly of reading and spelling impairments. Whole scale Cronbach's alphas were high for both interviews. The correlation between interviews for factor 1 was moderate (adult items 0.50; childhood items 0.43); Kappa values for between-interview agreement on individual items were mainly low. The correlations between individual items and total score were moderate. The inclusion of several factor 2 items lowered the overall Cronbach's alpha for the total set. Both interview measures showed good reliability and substantial stability over time, but the findings were better for factor 1 than factor 2. We recommend factor 1 scores be used for characterising the BAP. © 2015 The Authors Autism Research published by Wiley Periodicals, Inc. on behalf of International Society for Autism Research.
Kurre, Annette; van Gool, Christel J A W; Bastiaenen, Caroline H G; Gloor-Juzi, Thomas; Straumann, Dominik; de Bruin, Eling D
2009-04-01
To translate the Dizziness Handicap Inventory into German (DHI-G) and investigate reliability, assess the association between selected items of the University of California Los Angeles Dizziness Questionnaire and the DHI-G, and compare the scores of patients and healthy participants. Cross-sectional design. Tertiary center for vertigo, dizziness, or balance disorders. One hundred forty-one patients with vertigo, dizziness, and unsteadiness associated with a vestibular disorder, with a mean age (standard deviation) of 51.5 (13.2) years, and 52 healthy individuals participated. Fourteen patients participated in the cognitive debriefing; 127 patients completed the questionnaires once or twice within 1 week. The DHI-G assesses disability caused by dizziness and unsteadiness; the items of the University of California Los Angeles Dizziness Questionnaire assess dizziness and impact on everyday activities. Internal consistency was estimated using Cronbach alpha, reproducibility by calculating Bland-Altman limits of agreement and intraclass correlation coefficients. Associations were estimated by Spearman correlation coefficients. Patients filled out the DHI-G without problem and found that their self-perceived disabilities were mostly included. Cronbach alpha values for the DHI-G and the functional, physical, and emotional subscales were 0.90, 0.80, 0.71, and 0.82, respectively. The limits of agreement were +/-12.4 points for the total scale (maximum, 100 points). Intraclass correlation coefficients ranged from 0.90 to 0.95. The DHI-G correlated moderately with the question assessing functional disability (0.56) and fairly with the questions quantifying dizziness (0.43, 0.35). The DHI-G discriminated significantly between healthy participants and patients. The DHI-G demonstrated good reliability and is recommended as a measure of disability in patients with dizziness and unsteadiness.
Joshi, Veena D; Malhotra, Rahul; Lim, Jeremy F Y; Østbye, Truls; Wong, Michael
2010-05-01
The 12-item Expectations Regarding Aging (ERA-12) instrument measures expectations that individuals have about how their health and cognitive function will be when they age. To date, primarily assessed among older adults in Western settings, expectations regarding ageing have been associated with physical activity and healthcare seeking behaviour. It has been suggested that it may be possible to develop interventions that promote positive expectations about ageing. Assessment of expectations regarding ageing among today's middle-aged population would allow for earlier interventions to help give them positive (but realistic) ageing expectations, and age successfully. We assess the reliability and validity of ERA-12 for middle-aged Singaporeans. A questionnaire that included ERA-12 was administered to 1020 patients aged 41 to 62 years attending 2 SingHealth polyclinics in Singapore. Data from 981 respondents who completed the ERA-12 instrument were analysed. ERA-12's construct validity was determined using Exploratory Factor Analysis (EFA), and through its correlation with depressive symptoms, and self-rated health and education. Internal consistency reliability was assessed using Cronbach's alpha. EFA confirmed that the ERA-12 consisted of 3 factors (each with 4 items)--expectations regarding physical health, mental health and cognitive function, together explaining 64% of the variance in ERA-12 total score with high factor loadings (range, 0.6 to 0.8). The ERA-12 total score was positively correlated with self-rated health (r = 0.13) and education (r = 0.19), and negatively correlated with depressive symptoms (r = -0.25). Cronbach's alpha exceeded 0.7 for ERA-12 overall, and for each subscale. ERA-12 can be used to evaluate expectations regarding ageing not only among elderly populations in the West, but also among middle-aged Singaporeans.
Translation and Validation of the Persian Version the Boston Carpal Tunnel Syndrome Questionnaire.
Hassankhani, Golnaz Ghayyem; Moradi, Ali; Birjandinejad, Ali; Vahedi, Ehsan; Kachooei, Amir R; Ebrahimzadeh, Mohammad H
2018-01-01
Carpal tunnel syndrome (CTS) is recognized as the most common type of neuropathies. Questionnaires are the method of choice for evaluating patients with CTS. Boston Carpal Tunnel Syndrome (BCTS) is one of the most famous questionnaires that evaluate the functional and symptomatic aspects of CTS. This study was performed to evaluate the validity and reliability of the Persian version of BCTS questionnaire. First, both parts of the original questionnaire (Symptom Severity Scale and Functional Status Scale) were translated into Persian by two expert translators. The translated questionnaire was revised after merging and confirmed by an orthopedic hand surgeon. The confirmed questionnaire was interpreted back into the original language (English) to check for any possible content inequality between the original questionnaire and its final translated version. The final Persian questionnaire was answered by 10 patients suffering from CTS to elucidate its comprehensibility; afterwards, it was filled by 142 participants along with the Persian version of the Quick-DASH questionnaire. After 2 to 6 days, the translated questionnaire was refilled by some of the previous patients who had not received any substantial medical treatment during that period. Among all 142 patients, 13.4 % were male and 86.6 % were female. The reliability of the questionnaire was tested using Cronbach's alpha and Intraclass correlation coefficient (ICC). Cronbach's alpha was 0.859 for symptom severity scale (SSS) and 0.878 for functional status scale (FSS). Also, ICCs were calculated as 0.538 for SSS and 0.773 for FSS. In addition, construct validity of SSS and FSS against QuickDASH were 0.641 and 0.701, respectively. Based on our results, the Persian version of the BCTQ is valid and reliable. Level of evidence: II.
Ofenloch, Robert F; Diepgen, Thomas L; Popielnicki, Ana; Weisshaar, Elke; Molin, Sonja; Bauer, Andrea; Mahler, Vera; Elsner, Peter; Schmitt, Jochen; Apfelbacher, Christian
2015-02-01
The Occupational Contact Dermatitis Disease Severity Index (ODDI) was designed in Australia to measure severity and functional disability in patients with occupational contact dermatitis (OCD) of the hands. The ODDI was translated into the German language with a linguistic validation process. The psychometric properties of the German version of the ODDI are still unclear. To report the linguistic validation procedure and to perform a psychometric validation by investigating the validity and reliability of the German ODDI version in a sample of patients with OCD. Data were drawn from the baseline assessment (T0) and first follow-up (T1) of the German chronic hand eczema (CHE) registry (CARPE). Spearman correlations of the ODDI with reference measures were computed to assess validity. Cronbach's alpha was calculated as a measure of internal consistency, and the intraclass correlation coefficient (ICC) was calculated to assess retest reliability. The smallest real difference (SRD) and minimal clinically important difference (MCID) were calculated to assess sensitivity to change. Physician Global Assessment (PGA) was used as an anchor for the MCID. Four hundred and twenty-two patients (54.5% female, mean age 45.1 years) were included for analysis. Cronbach's alpha was found to be 0.73. The ICC was 0.79. Correlations between the ODDI total and the Dermatology Life Quality Index (rho = 0.36), and between PGA (rho = 0.48) and patient-assessed disease severity (rho = 0.40), were of moderate strength. The MCID (1.29) was found to be smaller than the SRD (1.87). The German ODDI version is reliable and valid for the measurement of functional impairment and disease severity in patients suffering from OCD. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Jain, Meena; Tandon, Shourya; Sharma, Ankur; Jain, Vishal; Rani Yadav, Nisha
2018-01-01
Background: An appropriate scale to assess the dental anxiety of Hindi speaking population is lacking. This study, therefore, aims to evaluate the psychometric properties of Hindi version of one of the oldest dental anxiety scale, Corah's Dental Anxiety Scale (CDAS) in Hindi speaking Indian adults. Methods: A total of 348 subjects from the outpatient department of a dental hospital in India participated in this cross-sectional study. The scale was cross-culturally adapted by forward and backward translation, committee review and pretesting method. The construct validity of the translated scale was explored with exploratory factor analysis. The correlation of the Hindi version of CDAS with visual analogue scale (VAS) was used to measure the convergent validity. Reliability was assessed through calculations of Cronbach's alpha and intra class correlation 48 forms were completed for test-retest. Results: Prevalence of dental anxiety in the sample within the age range of 18-80 years was 85.63% [95% CI: 0.815-0.891]. The response rate was 100 %. Kaiser-Meyer-Olkin (KMO) test value was 0.776. After factor analysis, a single factor (dental anxiety) was obtained with 4 items.The single factor model explained 61% variance. Pearson correlation coefficient between CDASand VAS was 0.494. Test-retest showed the Cronbach's alpha value of 0.814. The test-retest intraclass correlation coefficient of the total CDAS score was 0.881 [95% CI: 0.318-0.554]. Conclusion: Hindi version of CDAS is a valid and reliable scale to assess dental anxiety in Hindi speaking population. Convergent validity is well recognized but discriminant validity is limited and requires further study.
Huang, Qingmei; Jiang, Ping; Zhang, Zijun; Luo, Jie; Dai, Yun; Zheng, Li; Wang, Wei
2017-12-01
The Memorial Anxiety Scale for Prostate Cancer (MAX-PC) was developed to identify and assess cancer-specific anxiety among men with prostate cancer (PCa); however, there is no Chinese version. The aim of our study was to translate the English version of MAX-PC into Chinese and evaluate the psychometric properties of it. The study cohort comprised 254 participants. Internal consistency including the Cronbach's alpha coefficient and item-total correlations were used to measure the reliability of the scale. Factor structure was analyzed by exploratory factor analysis and concurrent validity by comparing MAX-PC scores with anxiety subscale scores of the Hospital Anxiety and Depression Scale (HADS). Divergent validity was assessed by correlating MAX-PC with HADS depression subscale, while discriminant ability by comparing differences in MAX-PC scores between different patient groups. The Chinese version of MAX-PC demonstrated good reliability; the Cronbach's alpha coefficient for the total and three subscales (prostate cancer anxiety, PSA anxiety, and fear of recurrence) being 0.94, 0.93, 0.82, and 0.85, respectively. Exploratory factor analysis supported the three-factor structure of the scale established in the original version. Despite the somewhat underperformed divergent validity, the scale demonstrated good concurrent validity with a strong correlation with the HADS anxiety subscale (r = 0.71, p < 0.01). Moreover, discriminant ability was demonstrated by ability to differentiate between disease stages. The MAX-PC Chinese version was confirmed to be a valid, reliable instrument and is thus appropriate for identifying and quantifying cancer-specific anxiety in Chinese PCa patients.
Abdovic, Slaven; Mocic Pavic, Ana; Milosevic, Milan; Persic, Mladen; Senecic-Cala, Irena; Kolacek, Sanja
2013-12-01
To assess the reliability and validity of IMPACT-III (HR), a disease-specific, health-related quality of life instrument in Croatian children with inflammatory bowel disease. In a multicenter study, 104 children participated in a validation study of IMPACT-III (HR) cross-culturally adapted for Croatia. Factor analysis was used to determine optimal domain structure for this cohort, analysis of Cronbach's alpha coefficients to test internal reliability, ANOVA to assess discriminant validity, and correlation with Pediatric Quality of Life Inventory, Version 4.0 (PedsQL) using Pearson correlation coefficients to assess concurrent validity. Cronbach's alpha for the IMPACT-III (HR) total score was 0.92. The most robust factor solution was a 5-domain structure: Symptoms, Concerns, Socializing, Body Image, and Worry about Stool, all of which demonstrated good internal reliability (α=0.60-0.89), but two items were dropped to achieve this. Discriminant validity was demonstrated by significant differences (P<0.001) in mean IMPACT-III (HR) scores between quiescent and mild or moderate-severe disease activity groups for total (148 vs. 139 or 125) and following factor scores: Symptoms (84 vs. 71 or 61), Socializing (91 vs. 83 or 76), and Worry about Stool (significant only between quiescent and moderate-severe groups, 90 vs. 62, respectively). Concurrent validity of IMPACT-III (HR) with PedsQL showed significant correlation, which was strongest when similar domains were compared. IMPACT-III (HR) appears to be useful tool to measure health-related quality of life in Croatian children with Crohn's disease and ulcerative colitis. Copyright © 2012 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.
Promoting the Quality of Health Research-based News: Introduction of a Tool
Ashoorkhani, Mahnaz; Majdzadeh, Reza; Nedjat, Saharnaz; Gholami, Jaleh
2017-01-01
Introduction: While disseminating health research findings to the public, it is very important to present appropriate and accurate information to give the target audience a correct understanding of the subject matter. The objective of this study was to design and psychometrically evaluate a checklist for health journalists to help them prepare news of appropriate accuracy and authenticity. Methods: The study consisted of two phases, checklist design and psychometrics. Literature review and expert opinion were used to extract the items of the checklist in the first phase. In the second phase, to assess content and face validity, the judgment of 38 persons (epidemiologists with a tool production history, editors-in-chief, and health journalists) was used to check the items’ understandability, nonambiguity, relevancy, and clarity. Reliability was assessed by the test–retest method using intra-cluster correlation (ICC) indices in the two phases. Cronbach's alpha was used to assess internal validity of the checklist. Results: Based on the participants’ opinions, the items were reduced from 20 to 14 in number. The items were categorized into the following three domains: (a) items assessing the source of news and its validity, (b) items addressing the presentation of complete and accurate information on research findings, and (c) items which if adhered to lead to the target audiences’ better understanding. The checklist was approved for content and face validity. The reliability of the checklist was assessed in the last stage; the ICC was 1 for 12 items and above 0.8 for the other two. Internal consistency (Cronbach's alpha) was 0.98. Discussion and Conclusions: The resultant indices of the study indicate that the checklist has appropriate validity and reliability. Hence, it can be used by health journalists to develop health research-based news. PMID:29184638
Saligan, Leorey N; Luckenbaugh, David A; Slonena, Elizabeth E; Machado-Vieira, Rodrigo; Zarate, Carlos A
2015-09-01
Fatigue is a complex, multidimensional condition. Although it is often associated with depression, it is not known whether it has a distinct network from depression or whether it can be clinically evaluated, separately. This study describes preliminary findings in the development of a brief, clinician-administered instrument to measure fatigue in the context of depressive disorders using items from existing clinician-administered depression and mania scales. Based on items from prior fatigue measurements, items were selected from the Hamilton Depression Rating Scale (HDRS), Montgomery-Asberg Depression Rating Scale (MADRS), Young Mania Rating Scale, and Structured Interview Guide for HDRS with Atypical Depression. The final items composed the NIH-Brief Fatigue Inventory (NIH-BFI). Responses from 89 depressed adults collected pre- and post-antidepressant therapy (ADT) determined the reliability and consistency of the NIH-BFI using Cronbach's alpha and principal components analysis (PCA). Correlations of the NIH-BFI and fatigue items from other scales before and after ADT explored validity. The 7-item NIH-BFI had Cronbach alphas ranging from 0.81 to 0.88 and PCA indicating a single dimension. The NIH-BFI score was strongly correlated (r = 0.73, p < 0.001) with fatigue items from Beck Depression Index, with MADRS without fatigue items (r = 0.77, p < 0.001), and HDRS without fatigue items (pre: r = 0.69, p < 0.001). Preliminary findings show support for internal consistency reliability and validity of the NIH-BFI, a clinician-administered measure of fatigue. Further testing in other clinical populations is recommended to obtain additional information on reliability and validity. The NIH-BFI provides a method for clinician-rated fatigue that may be a separate from depression. Published by Elsevier Ltd.
Mousavian, Alireza; Kachooie, Amir Reza; Birjandinejad, Ali; Khoshsaligheh, Masood; Ebrahimzadeh, Mohammad Hosein
2018-01-01
Background: This study aimed Persian translation and validation of the hip disability and osteoarthritis outcome score (HOOS) questionnaire. Methods: The study was carried out in two phases. First, we translated the HOOS according to acceptable guidelines. We assessed HOOS content convergent validity on 203 hip osteoarthritis patients using SF-36. Internal consistency was tested using Cronbach's alpha coefficient if each item removed and intraclass correlation coefficient (ICC) for the assessment of test-retest reproducibility. Results: Patients had mean (standard deviation) age of 39 (17). Test-retest ICC in whole was 0.95 (P = 0.014) showing excellent reliability. ICC was 0.92 for the “pain” subscale (P = 0.02), 0.81 for the “symptom” subscale (P = 0.002), 0.81 for the “function of daily living (FDL)” (P = 0.022), 0.88 for the “function of sports and recreational activities” (P = 0.006), but it was 0.62 (P = 0.1) for the “quality of life (QOL).” Cronbach's alpha was 0.92, 0.73, 0.97, 0.86, 0.80, and 0.80 for the pain, symptom, FDL, function of sports, QOL, and stiffness, respectively, showing good to excellent internal consistancy. Having SF-36 for the assessment of convergent validity, there was a strong correlation between total HOOS score and the physical component summary domain of SF-36 (r = 0.64, P = 0.0001), whereas the t correlation with the mental component summary domain was weak (r = 0.16, P = 0.04). Conclusions: The Persian version of the HOOS questionnaire is a valid (regarding physical not mental aspects) and reliable assessment tool in patients with hip osteoarthritis. PMID:29619147
Validation of the Brazilian version of the Burn Specific Health Scale-Brief (BSHS-B-Br).
Piccolo, Monica Sarto; Gragnani, Alfredo; Daher, Ricardo Piccolo; Scanavino, Marco de Tubino; de Brito, Maria José; Ferreira, Lydia Masako
2015-11-01
Progressive increases in survival rates from burn trauma have shifted attention to patient rehabilitation and posttraumatic quality of life. The assessment of quality of life is strongly dependent on reliable instruments for its measurement. A literature review has revealed that the Burn Specific Health Scale-Brief (BSHS-B) questionnaire is the most commonly used instrument worldwide. The aim of this study was to translate the BSHS-B into the Portuguese language, adapt it culturally to the Brazilian population, and test its psychometric properties. The questionnaire was translated into Portuguese; culturally adapted; and tested for reproducibility, face validity, content validity, and construct validity. The translated version was tested on 92 patients with burns. Internal consistency was tested by means of Cronbach's alpha. Construct validity was performed by correlating the BSHS-B questionnaire with the Burn Specific Health Scale-Revised (BSHS-R), BurnSexQ-Escola Paulista de Medicina (EPM)/Universidade Federal De São Paulo (UNIFESP), the Rosenberg Self-Esteem Scale (RSES), and the Beck Depression Inventory (BDI). Cronbach's alpha was 0.85. The Pearson correlation coefficients were significant at three time points of the reliability analysis. A significant correlation was observed between BSHS-B domains and BSHS-R, and between RSES and BDI domains. A significant correlation was also observed between BSHS-B and the BurnSexQ-EPM/UNIFESP social comfort and body image domains. The BSHS-B questionnaire was translated into Portuguese. It is a reliable tool in this language, showing face, content, and construct validity. The modified instrument has been named BSHS-B-Br. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Göras, Camilla; Wallentin, Fan Yang; Nilsson, Ulrica; Ehrenberg, Anna
2013-03-19
Tens of millions of patients worldwide suffer from avoidable disabling injuries and death every year. Measuring the safety climate in health care is an important step in improving patient safety. The most commonly used instrument to measure safety climate is the Safety Attitudes Questionnaire (SAQ). The aim of the present study was to establish the validity and reliability of the translated version of the SAQ. The SAQ was translated and adapted to the Swedish context. The survey was then carried out with 374 respondents in the operating room (OR) setting. Data was received from three hospitals, a total of 237 responses. Cronbach's alpha and confirmatory factor analysis (CFA) was used to evaluate the reliability and validity of the instrument. The Cronbach's alpha values for each of the factors of the SAQ ranged between 0.59 and 0.83. The CFA and its goodness-of-fit indices (SRMR 0.055, RMSEA 0.043, CFI 0.98) showed good model fit. Intercorrelations between the factors safety climate, teamwork climate, job satisfaction, perceptions of management, and working conditions showed moderate to high correlation with each other. The factor stress recognition had no significant correlation with teamwork climate, perception of management, or job satisfaction. Therefore, the Swedish translation and psychometric testing of the SAQ (OR version) has good construct validity. However, the reliability analysis suggested that some of the items need further refinement to establish sound internal consistency. As suggested by previous research, the SAQ is potentially a useful tool for evaluating safety climate. However, further psychometric testing is required with larger samples to establish the psychometric properties of the instrument for use in Sweden.
Leppert, Wojciech; Majkowicz, Mikolaj; Ahmedzai, Sam H
2012-12-01
Assessment of the needs of advanced cancer patients is a very important issue in palliative care. The aim of the study was to adapt the Sheffield Profile for Assessment and Referral for Care (SPARC) to the Polish environment and evaluate its usefulness in needs assessment of patients with advanced cancer. A forward-back translation of the SPARC to Polish was done. The SPARC was used once in 58 consecutive patients with advanced cancer during follow-up. The patients were enrolled from a palliative care unit (25 patients), home care (18 patients), and a day care center (15 patients). The reliability was evaluated by establishing the internal consistency using Cronbach's alpha coefficients. Content validity was analyzed in accordance with the theories of needs by Murray and Maslow as a nonstatistical method of validity assessment. Factor analysis with principal components extraction and varimax rotation of raw data was used to reduce the set of data and assess the construct validity. There were differences regarding religious and spiritual issues and independence and activity between patients in the palliative care unit (worse results) and those at the day care center (better scores). Communication and need for more information items were associated with psychological, social, spiritual, and treatment issues. Cronbach's alpha coefficients and factor analysis demonstrated, respectively, satisfactory reliability and construct validity of the tool. The study demonstrated that the Polish version of the SPARC is a valid and reliable tool recommended for the needs assessment and symptom evaluation of patients with advanced cancer. Copyright © 2012 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.
The Trauma Center Organizational Culture Survey: development and conduction.
Davis, Matthew L; Wehbe-Janek, Hania; Subacius, Haris; Pinto, Ruxandra; Nathens, Avery B
2015-01-01
The Trauma Center Organizational Culture Survey (TRACCS) instrument was developed to assess organizational culture of trauma centers enrolled in the American College of Surgeons Trauma Quality Program (ACS TQIP). The objective is to provide evidence on the psychometric properties of the factors of TRACCS and describe the current organizational culture of TQIP-enrolled trauma centers. A cross-sectional study was conducted by surveying a sampling of employees at 174 TQIP-enrolled trauma centers. Data collection was preceded by multistep survey development. Psychometric properties were assessed by an exploratory factor analysis (construct validity) and the item-total correlations and Cronbach alpha were calculated (internal reliability). Statistical outcomes of the survey responses were measured by descriptive statistics and mixed effect models. The response rate for trauma center participation in the study was 78.7% (n = 137). The factor analysis resulted in 16 items clustered into three factors as described: opportunity, pride, and diversity, trauma center leadership, and employee respect and recognition. TRACCS was found to be highly reliable with a Cronbach alpha of 0.90 in addition to the three factors (0.91, 0.90, and 0.85). Considerable variability of TRACCS overall and factor score among hospitals was measured, with the largest interhospital deviations among trauma center leadership. More than 80% of the variability in the responses occurred within rather than between hospitals. TRACCS was developed as a reliable tool for measuring trauma center organizational culture. Relationships between TQIP outcomes and measured organizational culture are under investigation. Trauma centers could apply TRACCS to better understand current organizational culture and how change tools can impact culture and subsequent patient and process outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.
Crins, Martine H P; Roorda, Leo D; Smits, Niels; de Vet, Henrica C W; Westhovens, Rene; Cella, David; Cook, Karon F; Revicki, Dennis; van Leeuwen, Jaap; Boers, Maarten; Dekker, Joost; Terwee, Caroline B
2015-01-01
The Dutch-Flemish PROMIS Group translated the adult PROMIS Pain Interference item bank into Dutch-Flemish. The aims of the current study were to calibrate the parameters of these items using an item response theory (IRT) model, to evaluate the cross-cultural validity of the Dutch-Flemish translations compared to the original English items, and to evaluate their reliability and construct validity. The 40 items in the bank were completed by 1085 Dutch chronic pain patients. Before calibrating the items, IRT model assumptions were evaluated using confirmatory factor analysis (CFA). Items were calibrated using the graded response model (GRM), an IRT model appropriate for items with more than two response options. To evaluate cross-cultural validity, differential item functioning (DIF) for language (Dutch vs. English) was examined. Reliability was evaluated based on standard errors and Cronbach's alpha. To evaluate construct validity correlations with scores on legacy instruments (e.g., the Disabilities of the Arm, Shoulder and Hand Questionnaire) were calculated. Unidimensionality of the Dutch-Flemish PROMIS Pain Interference item bank was supported by CFA tests of model fit (CFI = 0.986, TLI = 0.986). Furthermore, the data fit the GRM and showed good coverage across the pain interference continuum (threshold-parameters range: -3.04 to 3.44). The Dutch-Flemish PROMIS Pain Interference item bank has good cross-cultural validity (only two out of 40 items showing DIF), good reliability (Cronbach's alpha = 0.98), and good construct validity (Pearson correlations between 0.62 and 0.75). A computer adaptive test (CAT) and Dutch-Flemish PROMIS short forms of the Dutch-Flemish PROMIS Pain Interference item bank can now be developed.
The Pittsburgh Sleep Quality Index: validation of the Urdu translation.
Hashmi, Ali Madeeh; Khawaja, Imran Shuja; Butt, Zeeshan; Umair, Muhammad; Naqvi, Suhaib Haider; Jawad-Ul-Haq
2014-02-01
To translate and validate the Pittsburgh Sleep Quality Index (PSQI), a standardized self-administered questionnaire for the assessment of subjective sleep quality into the Urdu language. Validation study. Mayo Hospital, Lahore, from March to April 2012. The PSQI was translated into Urdu following standard guidelines. The final Urdu version (PSQI-U) was administered to 200 healthy volunteers comprising medical students, nursing staff and doctors. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation of component scores with global score was assessed by calculating Spearman correlation coefficient. Correlation between global PSQI-U scores at baseline with global scores for each PSQI-U and PSQI-E at 4-week interval was evaluated by calculating Spearman correlation coefficient. Moreover, scores on individual items of the scale at baseline were compared with respective scores after 4-week by t-test. One hundred and eighty five (185) participants completed the PSQI-U at baseline. The Cronbach alpha for PSQI-U was 0.56. Scores on individual components of the PSQI-U and composite scores were all highly correlated with each other (all p-values < 0.01). Composite scores for PSQI-U at baseline and PSQI-E at 4-week interval were also highly correlated with each other (Spearman correlation coefficient 0.74, p-value < 0.01) indicating good linguistic interchangeability. Composite scores for PSQI-U at baseline and at 4-week interval were positively correlated with each other (Spearman correlation coefficient 0.70, p < 0.01) indicating good test-retest reliability. The PSQI-U is a valid and reliable instrument for the assessment of sleep quality. It shows good linguistic interchangeability and test-retest reliability in comparison to the original English version when applied to individuals who speak the Urdu language. The PSQI-U can be a tool either for clinical management or research.
Evaluation of a word recognition instrument to test health literacy in dentistry: the REALD-99.
Richman, Julia A; Lee, Jessica Y; Rozier, R Gary; Gong, Debra A; Pahel, Bhavna T; Vann, William F
2007-01-01
This study aims to evaluate a dental health literacy word recognition instrument. Based on a reading recognition test used in medicine, the Rapid Estimate of Adult Literacy in Medicine (REALM), we developed the Rapid Estimate of Adult Literacy in Dentistry (REALD-99). Parents of pediatric dental patients were recruited from local dental clinics and asked to read aloud words in both REALM and REALD-99. REALD-99 scores had a possible range of 0 (low literacy) to 99 (high literacy); REALM scores ranged from 0 to 66. Outcome measures included parents' perceived oral health for themselves and of their children, and oral health-related quality of life of the parent as measured by the short-form Oral Health Impact Profile (OHIP-14). To determine the validity, we tested bivariate correlations between REALM and REALD-99, REALM and perceived dental outcomes, and REALD-99 and perceived dental outcomes. We used ordinary least squares regression and logit models to further examine the relationship between REALD-99 and dental outcomes. We determined internal reliability using Cronbach's alpha. One hundred two parents of children were interviewed. The average REALD-99 and REALM-66 scores were high (84 and 62, respectively). REALD-99 was positively correlated with REALM (PCC = 0.80). REALM was not related to dental outcomes. REALD-99 was associated with parents' OHIP-14 score in multivariate analysis. REALD-99 had good reliability (Cronbach's alpha = 0.86). REALD-99 has promise for measuring dental health literacy because it demonstrated good reliability and is quick and easy to administer. Additional studies are needed to examine the validity of REALD-99 using objective clinical oral health measures and more proximal outcomes such as behavior and compliance to specific health instructions.
Duracinsky, Martin; Lalanne, Christophe; Le Coeur, Sophie; Herrmann, Susan; Berzins, Baiba; Armstrong, Andrew Richard; Lau, Joseph Tak Fai; Fournier, Isabelle; Chassany, Olivier
2012-04-15
This study reports the psychometric validation of a new HIV/AIDS-specific health-related quality of life (HRQL) questionnaire, the Patient Reported Outcomes Quality of Life-HIV. The instrument was developed simultaneously across Europe, North and South America, Africa, Asia, and Australia to assess multidimensional quality of life impairments in the era of highly active antiretroviral therapy. A cross-sectional study was performed in 8 countries. The pilot 70-item questionnaire was co-administered with the HIV symptoms index, the EQ-5D and Medical Outcomes Study-HIV questionnaires. Demographic and biomedical data were collected. After item analysis and reduction, convergent discriminant concurrent validity and known-group validity were examined. Internal consistency and reliability scores were assessed using Cronbach alpha and intraclass correlation. The final sample of 791 patients was composed of 64% males (median age: 41 years, HIV diagnosis = 5 years), 13.8% were treatment naive. Item reduction yielded a 43-item form surveying 8 dimensions and 1 global health item that showed good convergent and discriminant validity and reliability (98% scaling success; Cronbach alphas 0.77-0.89). Correlations with EQ-5D and Medical Outcomes Study-HIV complied with concurrent validity expectations; likewise, correlations against the number of self-reported symptoms and depression showed good support for criterion validity. A test-retest study on French patients (n = 34) showed temporal stability (intraclass correlation coefficient = 0.86). Significant and meaningful differences of HRQL scores between countries were found. The Patient Reported Outcomes Quality of Life-HIV questionnaire is a valid and reliable instrument for assessing HRQL specific to HIV disease in different cultures and healthcare systems.
El Fakir, Samira; Abda, Naima; Bendahhou, Karima; Zidouh, Ahmed; Bennani, Maria; Errihani, Hassan; Benider, Abdelatif; Bekkali, Rachid; Nejjari, Chakib
2014-01-21
Quality of life (QOL) and its measurement in cancer patients is becoming increasingly important. Breast cancer diagnosis and treatment are often associated with psychological distress and reduced QoL. In Arabic-speaking countries, QoL of patients with cancer is inadequately studied.The aim of this study was to test the reliability and validity of the Moroccan Arabic version of the European Organization for Research and Treatment of Cancer (EORTC) Breast Cancer-Specific Quality of Life Questionnaire (QLQ-BR23). After translation and cross-cultural adaptation, the questionnaire was tested on breast cancer patients. The participants' number for the test and the retest were 105 and 37 respectively. Internal consistency was tested using Cronbach's alpha coefficient (α), the test-retest reliability using intraclass correlation coefficients (ICC). Construct validity was assessed by examining item-convergent and divergent validity. The questionnaire was administered to 105 patients. The mean age of patients was 48 years (SD: 16), 62.9% were married. 68.6% of all participants lived in urban area.The average time to complete the QLQ- BR23 was 15 min. Cronbach's alpha coefficient, were all >0.7, with the exception of breast symptoms and arm symptoms. All items exceeded the 0.4 criterion for convergent validity except item 20 and 23 related to pain and skin problems in the affected breast respectively. In general, the findings of this study indicated that the Moroccan Arabic version of the EORTC QLQ-BR23 is a reliable and valid supplementary measure of the QOL in breast cancer patients and can be used in clinical trials and studies of outcome research in oncology.
[Checklist Development for Women-Doctor-Friendly Working Conditions in a Hospital Setting].
Horie, Saki; Takeuchi, Masumi; Yamaoka, Kazue; Nohara, Michiko; Hasunuma, Naoko; Okinaga, Hiroko; Nomura, Kyoko
2015-01-01
This study aims to develop a scale of "women-doctor-friendly working conditions in a hospital setting". A task team consisting of relevant people including a medical doctor and a hospital personnel identified 36 items related to women-doctor-friendly working conditions. From December in 2012 to January in 2013, we sent a self-administered questionnaire to 807 full-time employees including faculty members and medical doctors who worked for a university-affiliated hospital. We asked them to score the extent to which they think it is necessary for women doctors to balance between work and gender role responsibilities on the basis of the Likert scale. We carried out a factor analysis and computed Cronbach's alpha to develop a scale and investigated its construct validity and reliability. Of the 807 employees, 291 returned the questionnaires (response rate, 36.1%). The item-total correlation (between an individual item score and the total score) coefficient was in the range from 0.44 to 0.68. In factor analysis, we deleted six items, and five factors were extracted on the basis of the least likelihood method with the oblique Promax rotation. The factors were termed "gender equality action in an organization", "the compliance of care leave in both sexes and parental leave in men", "balance between life events and work", "childcare support at the workplace", and "flexible employment status". The Cronbach's alpha values of all the factors and the total items were 0.82-0.89 and 0.93, respectively, suggesting that the scale we developed has high reliability. The result indicated that the scale of women-doctor-friendly working conditions consisting of five factors with 30 items is highly validated and reliable.
Pilot assessment of pain of orthopaedic patients in Hong Kong.
Chan, Shuk Fong; Ho, Samuel M Y; Poon, Kam Wa; Ip, Arthur; Cheung, Ophelia Y Y
2005-04-01
This pilot study examined the internal consistency and concurrent validity of the Chinese version of the Acute Lower Back Pain Screening Questionnaire. A sample of 45 acute low back pain patients (27 men and 18 women; mean age = 47.8) were recruited from the Department of Orthopaedics and Traumatology of the Tuen Mun Hospital in Hong Kong. Three items of the original questionnaire were excluded from the analyses because response was low by 30 of the 45 patients. The questionnaire showed good internal reliability (Cronbach alpha = .88) and correlated significantly with other test scores: the Faces Pain Scale-Revised (alpha = .74), the Chinese (Hong Kong) SF-12 Health Survey (Mental subscale, alpha = -.47; Physical subscale alpha = -.62), and the Chinese Hospital Anxiety and Depression Scale (Anxiety subscale, alpha = .42; Depression subscale, alpha = .43). The questionnaire could be used in research and clinical work to provide data on the multicomponents of a pain experience as well as psychosocial risk factors related to pain among the Chinese. Researchers might examine the course of change in chronic pain.
Ying, Yu-Wen; Lee, Peter Allen; Tsai, Jeanne L
2004-11-01
The Inventory of College Challenges for Ethnic Minority Students (ICCEMS) is a newly developed instrument that assesses challenges faced by ethnic minority college students across a range of cultural, academic, social, and practical domains. The present study tested the ICCEMS among Chinese American students in an attempt to identify its factor structure and assess its psychometric properties. A total of 13 factor domains emerged. The Cronbach's alpha and 1-month test-retest reliability of the subscales and the overall scale supported their reliability. Both criterion and construct validities were also demonstrated. Chinese American college students faced the greatest challenges in terms of unclear career direction and academic demands. 2004 APA
Sørensen, Hans Eibe; Slater, Stanley F
2008-08-01
Atheoretical measure purification may lead to construct deficient measures. The purpose of this paper is to provide a theoretically driven procedure for the development and empirical validation of symmetric component measures of multidimensional constructs. Particular emphasis is placed on establishing a formalized three-step procedure for achieving a posteriori content validity. Then the procedure is applied to development and empirical validation of two symmetrical component measures of market orientation, customer orientation and competitor orientation. Analysis suggests that average variance extracted is particularly critical to reliability in the respecification of multi-indicator measures. In relation to this, the results also identify possible deficiencies in using Cronbach alpha for establishing reliable and valid measures.
Gedikoglu, Umit; Ucler, Serap; Inan, Levent E; Coskun, Ozlem; Tunc, Tugba
2006-11-01
We have tested Turkish version of the Migraine Disability Assessment (MIDAS) questionnaire in patients with tension type headache. Thirty-two patients who had a tension type headache were included. Turkish version of the MIDAS questionnaire was applied to all patients. Additionally, the patients were asked to keep a 90-day diary. The day diary and the MIDAS questionnaire were compared at the end of the study period. We found that cronbach's alpha 0.82 and had good reliability. Our findings suggest that the MIDAS questionnaire that was originally designed for patients with migraine may be used in patients with chronic tension type headache.
DeSmet, A; Bastiaensens, S; Van Cleemput, K; Poels, K; Vandebosch, H; Deboutte, G; Herrewijn, L; Malliet, S; Pabian, S; Van Broeckhoven, F; De Troyer, O; Deglorie, G; Van Hoecke, S; Samyn, K; De Bourdeaudhuij, I
2018-06-01
.This paper describes the items, scale validity and scale reliability of a self-report questionnaire that measures bystander behavior in cyberbullying incidents among adolescents, and its behavioral determinants. Determinants included behavioral intention, behavioral attitudes, moral disengagement attitudes, outcome expectations, self-efficacy, subjective norm and social skills. Questions also assessed (cyber-)bullying involvement. Validity and reliability information is based on a sample of 238 adolescents (M age=13.52 years, SD=0.57). Construct validity was assessed using Confirmatory Factor Analysis (CFA) or Exploratory Factor Analysis (EFA) in Mplus7 software. Reliability (Cronbach Alpha, α) was assessed in SPSS, version 22. Data and questionnaire are included in this article. Further information can be found in DeSmet et al. (2018) [1].
Visual vertigo analogue scale: an assessment questionnaire for visual vertigo.
Dannenbaum, Elizabeth; Chilingaryan, Gevorg; Fung, Joyce
2011-01-01
A common symptom for people with vestibulopathy is dizziness induced by dynamic visual input, known as visual vertigo (VV). The goal of this study is to present a novel method to assess VV, using a nine-item analog scale. The subjects rated the intensity of their dizziness on each item of the Visual Vertigo Analogue Scale (VVAS), which represented a daily situation typically inducing VV. The questionnaire was completed by participants with vestibulopathy (n=102) and by subjects receiving out-patient orthopaedic physiotherapy (n=102). The dizziness handicap inventory (DHI) was also completed by the vestibulopathic group. The Cronbach's Alpha index indicated the VVAS is internally consistent and reliable (Cronbach's Alpha=0.94). The study also found that the VVAS severity scores from vestibular and a non-vestibular population were significantly different (Wilcoxon-Mann Whitney test p < 0.0001). Spearman correlation analysis conducted between DHI and VVAS scores for the clients with vestibulopathy showed positive moderate correlations between the VVAS score and the total DHI score (r=0.67, p< 0.0001). This study showed that the VVAS scale may be useful in providing a quantitative evaluation scale of visual vertigo.
Tomaschewski-Barlem, Jamila Geri; Lunardi, Valéria Lerch; Barlem, Edison Luiz Devos; da Silveira, Rosemary Silva; Dalmolin, Graziele de Lima; Ramos, Aline Marcelino
2015-01-01
Abstract Objective: to adapt culturally and validate the Protective Nursing Advocacy Scale for Brazilian nurses. Method: methodological study carried out with 153 nurses from two hospitals in the South region of Brazil, one public and the other philanthropic. The cross-cultural adaptation of the Protective Nursing Advocacy Scale was performed according to international standards, and its validation was carried out for use in the Brazilian context, by means of factor analysis and Cronbach's alpha as measure of internal consistency. Results: by means of evaluation by a committee of experts and application of pre-test, face validity and content validity of the instrument were considered satisfactory. From the factor analysis, five constructs were identified: negative implications of the advocacy practice, advocacy actions, facilitators of the advocacy practice, perceptions that favor practice advocacy and barriers to advocacy practice. The instrument showed satisfactory internal consistency, with Cronbach's alpha values ranging from 0.70 to 0.87. Conclusion: it was concluded that the Protective Nursing Advocacy Scale - Brazilian version, is a valid and reliable instrument for use in the evaluation of beliefs and actions of health advocacy, performed by Brazilian nurses in their professional practice environment. PMID:26444169
[Validation of French versions of magical ideation and perceptual aberrations questionnaires].
Dumas, P; Bouafia, S; Gutknecht, C; Saoud, M; Daléry, J; d'Amato, T
2000-01-01
Chapman and colleagues have developed symptom-oriented scales based on Meehl's manual of schizotypy, such as the Social Anhedonia (SA) and Physical Anhedonia (PhA) Scales, the Magical Ideation Scale (MIS), and the Perceptual Aberration Scale (PAS). Whereas Chapman's scales of psychosis proneness are the most internationally used instruments for the assessment of schizotypy, some of them, such as MIS and PAS, were still not available in French. We reported here the validation study of the MIS and the PAS French versions that we had published previously. This study was conducted in a sample of 233 students (males: n = 108; females: n = 125; mean age: 21.17 +/- 1.47; mean educational level: 13.36 +/- 1.06). The French versions of the MIS and the PAS have high internal reliability (MIS: Cronbach's alpha = 0.85; PAS: Cronbach's alpha = 0.88). French norms are given for each of these scales. They are respectively 19/30 for the MIS and 17/35 for the PAS high cutoff scores without any difference when gender was considered. These results are very closed to those found by Chapman and colleagues for University of Wisconsin undergraduate students.
Validation of the Hebrew version of the Burn Specific Health Scale-Brief questionnaire.
Stavrou, Demetris; Haik, Josef; Wiser, Itay; Winkler, Eyal; Liran, Alon; Holloway, Samantha; Boyd, Julie; Zilinsky, Isaac; Weissman, Oren
2015-02-01
The Burns Specific Health Scale-Brief (BSHS-B) questionnaire is a suitable measurement tool for the assessment of general, physical, mental, and social health aspects of the burn survivor. To translate, culturally adapt and validate the BSHS-B to Hebrew (BSHS-H), and to investigate its psychometric properties. Eighty-six Hebrew speaking burn survivors filled out the BSHS-B and SF-36 questionnaires. Ten of them (11.63%) completed a retest. The psychometric properties of the scale were evaluated. Internal consistency, criterion validity, and construct validity were assessed using interclass correlation coefficient, Cronbach's alpha statistic, Spearman rank test, and Mann-Whitney U test respectively. BSHS-H Cronbach's alpha coefficient was 0.97. Test-retest interclass coefficients were between 0.81 and 0.98. BSHS-H was able to discriminate between facial burns, hand burns and burns >10% body surface area (p<0.05). BSHS-H and SF-36 were positively correlated (r(2)=0.667, p<0.01). BSHS-H is a reliable and valid instrument for use in the Israeli burn survivor population. The translation and cross-cultural adaptation of this disease specific scale allows future comparative international studies. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Pisconti, Fernando; Mahmoud Smaili Santos, Suhaila; Lopes, Josiane; Rosa Cardoso, Jefferson; Lopes Lavado, Edson
2017-11-29
The Exercise Self-Efficacy scale (ESES) is a reliable measure, in the English language, of exercise self-efficacy in individuals with spinal cord injury. The aim of this study was to culturally adjust and validate the Exercise Self-Efficacy scale in the Portuguese language. The Exercise Self-Efficacy scale was applied to 76 subjects, with three-month intervals (three applications in total). The reliability was appraised using the intra-class correlation coefficient and Bland-Altman methods, and the internal consistency was evaluated using Cronbach´s alpha. The Exercise Self-Efficacy scale was correlated with the domains of the Quality of life Questionnaire SF-36 and Functional Independence Measure and tested using the Spearman rho coefficient. The Exercise Self-Efficacy scale-Brazil presented good internal consistency (alpha 1 = 0.856; alpha 2 = 0.855; alpha 3 = 0.822) and high reliability in the test-retest (intra-class correlation coefficient = 0.97). There was a strong correlation between the Exercise Self-Efficacy scale-Brazil and the SF-36 only in the functional capacity domain (rho = 0.708). There were no changes in Exercise Self-Efficacy scale-Brazil scores between the three applications (p = 0.796). The validation of the Exercise Self-Efficacy scale questionnaire permits the assessor to use it reliably in Portuguese speaking countries, since it is the first instrument measuring self-efficacy specifically during exercises in individuals with spinal cord injury. Furthermore, the questionnaire can be used as an instrument to verify the effectiveness of interventions that use exercise as an outcome. The results of the Brazilian version of the Exercise Self-Efficacy scale support its use as a reliable and valid measurement of exercise self-efficacy for this population.
Loo, Jo Lin; Ang, Yee Kwang; Yim, Hip Seng
2013-01-01
To describe the development and validation of a cancer awareness questionnaire (CAQ) based on a literature review of previous studies, focusing on cancer awareness and prevention. A total of 388 Chinese undergraduate students in a private university in Kuala Lumpur, Malaysia, were recruited to evaluate the developed self-administered questionnaire. The CAQ consisted of four sections: awareness of cancer warning signs and screening tests; knowledge of cancer risk factors; barriers in seeking medical advice; and attitudes towards cancer and cancer prevention. The questionnaire was evaluated for construct validity using principal component analysis and internal consistency using Cronbach's alpha (α) coefficient. Test-retest reliability was assessed with a 10-14 days interval and measured using Pearson product-moment correlation. The initial 77-item CAQ was reduced to 63 items, with satisfactory construct validity, and a high total internal consistency (Cronbach's α=0.77). A total of 143 students completed the questionnaire for the test-retest reliability obtaining a correlation of 0.72 (p<0.001) overall. The CAQ could provide a reliable and valid measure that can be used to assess cancer awareness among local Chinese undergraduate students. However, further studies among students from different backgrounds (e.g. ethnicity) are required in order to facilitate the use of the cancer awareness questionnaire among all university students.
Spanish version validation of the Marihuana Motives Measure in a drug-consuming adolescent sample.
Matali Costa, Josep; Simons, J; Pardo, M; Lleras, M; Pérez, A; Andión, O
2018-01-15
Cannabis is the illicit drug mostly widely consumed by adolescents in Spain. The understanding of consumption motives is an important factor for intervention. In Spain, there are no available instruments for their evaluation, hence, the goal of this paper is to study the psychometric properties of the Marihuana Motives Measure (MMM) in a sample of adolescent consumers. Firstly, translation and back-translation was performed. A total of 228 adolescent consumers of cannabis were evaluated. Factorial analysis was conducted, and the reliability of the total scores and of each scale of the questionnaire was studied through Cronbach's alpha. Test-retest reliability was analyzed through interclass correlations. Validity evidence of the MMM was examined through correlations between current cannabis use, subjective consumption effects measured with the Addiction Research Center Inventory (ARCI), and personality measured with the Millon Adolescent Clinical Inventory (MACI). High reliability was observed in total score of the MMM (Cronbach α = .86), and high and moderate reliability for each of the five factors obtained in the factorial analysis of the MMM, Social = .82, Enhancement = .72, Coping = .83, Expansion = .74, and Conformity = .64. Significant correlations were also observed between cannabis consumption motives and subjective effects, and between consumption motives and personality. The Spanish version of the MMM shows a similar factorial structure as the one obtained by the original author, and its measures are reliable and valid for the study of cannabis consumption motives in adolescent consumer population.
Irvine, D
1995-08-01
A study was conducted at two tertiary care hospitals in Canada for the purpose of developing instruments to measure organizational citizenship behaviours (OCB) and changes in job behaviours that occur as a result of participation on hospital quality improvement (CQI) teams. Semi structured interviews were conducted among 52 hospital employees in order to elicit critical incidents of OCB and changes in job behaviours related to CQI. The results of the staff interviews were used to develop a measure of OCB in the hospital setting, and a measure of changes in job behaviours related to CQI. 39 employees, who were drawn from the major departments within the two hospitals on the basis of their membership on CQI teams, participated in a test of the psychometric properties of the two research instruments. Exploratory factor analysis, employing an orthogonal rotation, yielded two factors that accounted for 30% of the variation among the OCB items. The Cronbach alpha for items loading highly on the first factor was .88. The factor was labelled 'OCB directed towards individuals within the organization'. This factor was dominated by items reflecting the kinds of extra-role job behaviours employees engage in to assist patients, family members, visitors, and other employees within the organization. The Cronbach alpha for items loading highly on the second factor was 0.71. The second factor was labelled 'organizationally directed OCB', and consisted of behaviours that reflected an impersonal form of OCB in the hospital setting. Factor analysis, employing an orthogonal rotation, yielded four factors that accounted for 48% of the variation among the items measuring changes in job behaviours related to CQI. The four factors were labelled 'problem-solving', Cronbach alpha 0.82; 'customer awareness', Cronbach alpha 0.79; 'use of CQI knowledge', Cronbach alpha 0.77; and 'organizational interests', Cronbach alpha 0.79. The two OCB factors were moderately correlated, there were no significant correlations among any of the factors measuring changes in job behaviours related to CQI, and the problem-solving job behaviours factor was moderately correlated with the two OCB factors. Directions for future research are discussed.
Bataclan, Rommel P; Dial, Ma Antonietta D
2009-10-01
Chronic kidney disease is the 10th leading cause of death among Filipinos. Those with chronic kidney disease are exposed to stressors which effect their daily lives. Therefore, assessment of health-related quality of life is important in these patients. The objective of the present study was to translate the Kidney Disease Quality of Life--Short Form version 1.3 (KDQOL-SF ver. 1.3) into Filipino and measure its validity and reliability. Translation and cultural adaptation began with two translations into Filipino, with reconciliation of the forward translators. Pretesting with 10 renal patients, review by experts (nephrologist, translator and dialysis nurse) and back-translation was also done. The final questionnaire was administered to 80 patients with chronic renal disease undergoing haemodialysis for at least 3 months, who could understand Filipino, and were without life-threatening or terminal conditions at the time of the test. A convenience sample of 30 patients from the group had a repeat test 10-14 days after to determine test-retest reliability. Test-retest reliability was assessed by intraclass correlation coefficient and internal consistency reliability was measured by determining the Cronbach's alpha value. Validity was measured using Pearson's correlation between the overall health rating scale and the items from the questionnaire. All of the items showed good test-retest reliability (intraclass correlation coefficient >0.40), ranging from 0.58 (social interaction) to 0.98 (role--emotional). Internal consistency reliability values were acceptable, with Cronbach's alpha ranging from 0.60 (cognitive function) to 0.80 (physical functioning and role--physical). Regarding construct validity, overall health rating in kidney disease-targeted scales was significantly correlated with symptoms/problems, effects of kidney disease and burden of kidney disease. All items in the SF 36 scales had significant correlation with overall health rating (P < 0.05) except for role--emotional. The Filipino version of the Kidney Disease Quality of Life--Short Form can be used to evaluate the health-related quality of life of Filipinos with chronic renal disease on haemodialysis.
Moeini, Babak; Zamanian, Hadi; Taheri-Kharameh, Zahra; Ramezani, Tahereh; Saati-Asr, Mohamadhasan; Hajrahimian, Mohamadhasan; Amini-Tehrani, Mohammadali
2018-01-01
Spirituality plays an important role in coping with chronic diseases for patients and they often report unmet spiritual and existential needs, which should be considered for a holistic view of their health. Studying spiritual needs in this generation requires culturally appropriate and valid instruments. The aim of this study was to determine the psychometric properties, such as validity, reliability, and factor structure of the Persian version of Spiritual Needs Questionnaire (SpNQ). The aim of this study was to determine the psychometric properties, such as validity, reliability, and factor structure of the Persian version of Spiritual Needs Questionnaire (SpNQ). The "forward-backward" procedure was applied to translate the SpNQ from English into Persian. The SpNQ-Persian Version (SpNQ-PV) was checked in terms of validity and reliability with a convenience sample of 100 elders with chronic diseases who were recruited from the inpatient wards at two university hospitals in Qom, Iran. The validity was assessed using content, face, and construct validity. The Cronbach alpha and test-retest were used to assess the reliability of the questionnaire. The results of the exploratory factor analysis indicated a five-factor solution for the questionnaire, which included religious needs, existential needs, forgiveness/generativity needs, need for inner peace, and emotional needs. These accounted for 60.1% of the total observed variance. One item was removed (factor loading <0.4). Convergent validity was supported mostly by the pattern of association between SpNQ-PV and the Spiritual Well-being Scale. Cronbach alpha of the subscales ranged from 0.56 to 0.78 and the test-retest reliability ranged from 0.72 to 0.91, which indicated an acceptable range of reliability. The SpNQ-PV showed a minor difference in structuring and indicated good psychometric properties, which can be used to assess the spiritual needs of Iranian elders suffering from chronic diseases. Copyright © 2017 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Aksoy Derya, Yeşim; Timur Taşhan, Sermin; Duman, Mesude; Durgun Ozan, Yeter
2018-07-01
The purpose of this study was to create a Turkish version of the Pregnancy-Related Anxiety Questionnaire-Revised 2 (PRAQR2), which was revised for application to multiparous and primiparous pregnancy, and to explore its psychometric characteristics in multiparous and primiparous pregnancy. This study was methodologically designed to assess the reliability and validity of the PRAQ-R2. The study was carried out in the obstetrics clinic of a training and research hospital in Malatya. A total of 616 healthy pregnant women (399 multiparous and 217 primiparous) constituted the sample of the study. The cultural adaptation process of the questionnaire was conducted in three phases: language validity, content validity, and pilot application. Exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) were used to test the construct validity of the questionnaire. The reliability of the PRAQ-R2 was evaluated with Cronbach's alpha internal consistency coefficient, item-total correlation, test-retest analysis, and parallel forms reliability. The EFA revealed that the PRAQ-R2 consists of 10 items for the multiparous group and 11 for the primiparous group after adding the item ``I am anxious about the delivery because I have never experienced one before.'' The CFA for both groups supported the three-factor questionnaire yielded by the EFA. Good fit index values were obtained in both groups. Cronbach's alpha internal consistency coefficient ranged from 0.81 to 0.93 for the multiparous group and 0.87 to 0.94 for the primiparous group for the complete PRAQ-R2 and each of its subdimensions. In addition, the item-total correlation, test-retest analysis, and parallel forms reliability of the questionnaire were highly correlated. The PRAQ-R2 is a valid and reliable instrument that can be used to evaluate the level of anxiety in Turkish pregnant women irrespective of parity. The use of the PRAQ-R2 in prenatal healthcare services will contribute to the early diagnosis, treatment, and management of pregnancy-related anxiety. Copyright © 2018 Elsevier Ltd. All rights reserved.
Alqarni, Ayidh M; Vennu, Vishal; Alshammari, Sulaiman A; Bindawas, Saad M
2018-01-01
Older adults are the fastest growing population group worldwide. Regular physical activity (PA) is reported to reduce the risk of health conditions and improve personal well-being. Few validated instruments can be used to measure the PA levels among older adults in Saudi Arabia. The Physical Activity Scale for the Elderly (PASE) is used worldwide for evaluating the PA levels of the elderly in epidemiological studies. However, this scale has not been translated into Arabic. This study aimed to cross-culturally adapt the PASE into Arabic language and evaluate its reliability and validity among community-dwelling older adults in Saudi Arabia. This study was a cross-sectional one following Beaton guidelines to translate and perform cultural adaptation, as well as test the reliability and validity of the PASE Arabic version (PASE-A). Elderly (N=74) people from both genders, who lived in a community dwelling in Riyadh city, were selected from several primary health care centers. The study used Cronbach's alpha coefficient to assess the internal consistency reliability, while intraclass correlation coefficient (ICC 2,1 ) was used for test-retest reliability and the Spearman's rank correlation coefficient ( r ) was used to evaluate the correlation among PASE-A and grip strength, Timed Up and Go test, body mass index, and fat percentage. Out of 74 older adults, 59 (79.7%) completed the PASE-A questionnaire twice. The internal consistency of the PASE-A components was good (Cronbach's alpha 0.70-0.75), and the reliability of the components was excellent (ICC 2,1 0.90-0.98). A higher PASE-A score was associated with higher grip strength ( r =0.28, p =0.05) and with shorter Timed Up and Go test times ( r =-0.45, p =0.01). The PASE-A version was easy, understandable, and relevant for Saudi older adults' culture. This scale was a reliable and valid tool for evaluating and assessing the PA level among community-dwelling older adults in Saudi Arabia.
A measure of satisfaction with food-related life.
Grunert, Klaus G; Dean, Moira; Raats, Monique M; Nielsen, Niels Asger; Lumbers, Margaret
2007-09-01
A measure of satisfaction with food-related life is developed and tested in three studies in eight European countries. Five items are retained from an original pool of seven; these items exhibit good reliability as measured by Cronbach's alpha, good temporal stability, convergent validity with two related measures, and construct validity as indicated by relationships with other indicators of quality of life, including the Satisfaction With Life and the SF-8 scales. It is concluded that this scale will be useful in studies trying to identify factors contributing to satisfaction with food-related life.
Factor structure of the Spanish version of the Object-Spatial Imagery and Verbal Questionnaire.
Campos, Alfredo; Pérez-Fabello, María José
2011-04-01
The reliability and factor structure of the Spanish version of the Object-Spatial Imagery and Verbal Questionnaire (OSIVQ) were assessed in a sample of 213 Spanish university graduates. The questionnaire measures three types of processing preferences (verbal, object imagery, and spatial imagery). Principal components analysis with varimax rotation identified three factors, corresponding to the three scales proposed in the original version, explaining 33.1% of the overall variance. Cronbach's alphas were .72, .77, and .81 for the verbal, object imagery, and spatial imagery scales, respectively.
Skill Assessment in the Interpretation of 3D Fracture Patterns from Radiographs
Rojas-Murillo, Salvador; Hanley, Jessica M; Kreiter, Clarence D; Karam, Matthew D; Anderson, Donald D
2016-01-01
Abstract Background Interpreting two-dimensional radiographs to ascertain the three-dimensional (3D) position and orientation of fracture planes and bone fragments is an important component of orthopedic diagnosis and clinical management. This skill, however, has not been thoroughly explored and measured. Our primary research question is to determine if 3D radiographic image interpretation can be reliably assessed, and whether this assessment varies by level of training. A test designed to measure this skill among orthopedic surgeons would provide a quantitative benchmark for skill assessment and training research. Methods Two tests consisting of a series of online exercises were developed to measure this skill. Each exercise displayed a pair of musculoskeletal radiographs. Participants selected one of three CT slices of the same or similar fracture patterns that best matched the radiographs. In experiment 1, 10 orthopedic residents and staff responded to nine questions. In experiment 2, 52 residents from both orthopedics and radiology responded to 12 questions. Results Experiment 1 yielded a Cronbach alpha of 0.47. Performance correlated with experience; r(8) = 0.87, p<0.01, suggesting that the test could be both valid and reliable with a slight increase in test length. In experiment 2, after removing three non-discriminating items, the Cronbach coefficient alpha was 0.28 and performance correlated with experience; r(50) = 0.25, p<0.10. Conclusions Although evidence for reliability and validity was more compelling with the first experiment, the analyses suggest motivation and test duration are important determinants of test efficacy. The interpretation of radiographs to discern 3D information is a promising and a relatively unexplored area for surgical skill education and assessment. The online test was useful and reliable. Further test development is likely to increase test effectiveness. Clinical Relevance Accurately interpreting radiographic images is an essential clinical skill. Quantitative, repeatable techniques to measure this skill can improve resident training and improve patient safety. PMID:27528827
Cui, Jin; Jia, Zhenyu; Zhi, Xin; Li, Xiaoqun; Zhai, Xiao; Cao, Liehu; Weng, Weizong; Zhang, Jun; Wang, Lin; Chen, Xiao; Su, Jiacan
2017-01-05
The Achilles tendon Total Rupture Score (ATRS), which is originally developed in 2007 in Swedish, is the only patient-reported outcome measure (PROM) for specific outcome assessment of an Achilles tendon rupture.Purpose of this study is to translate and cross-culturally adapt Achilles tendon Total Rupture Score (ATRS) into simplified Chinese, and primarily evaluate the responsiveness, reliability and validity. International recognized guideline which was designed by Beaton was followed to make the translation of ATRS from English into simplified Chinese version (CH-ATRS). A prospective cohort study was carried out for the cross-cultural adaptation. There were 112 participants included into the study. Psychometric properties including floor and ceiling effects, Cronbach's alpha, intraclass correlation coefficient, effect size, standard response mean, and construct validity were tested. The mean scores of CH-ATRS are 57.42 ± 13.70. No sign of floor or ceiling effect was found of CH-ATRS. High level of internal consistency was supported by the value of Cronbach's alpha (0.893). ICC (0.979, 95%CI: 0.984-0.993) was high to indicate the high test-retest reliability. Great responsive ness was proved with the high absolute value of ES and SRM (0.84 and 8.98, respectively). The total CH-ATRS score had very good correlation with physical function and body pain subscales of SF-36 (r = -0.758 and r = -0.694, respectively, p < 0.001), while poor correlation with vitality and role physical subscales of SF-36 (r = -0.033 and r = -0.025, respectively, p ≥ 0.05), which supported construct validity of CH-ATRS. This Chinese version of Achilles tendon Total Rupture Score (CH-ATRS) can be used as a reliable and valid instrument for Achilles tendon rupture assessing in Chinese-speaking population. Level of evidence II.
Remelhe, Mafalda; Teixeira, Pedro M; Lopes, Irene; Silva, Luís; Correia de Sousa, Jaime
2017-01-12
Enabling patients with asthma to obtain the knowledge, confidence and skills they need in order to assume a major role in the management of their disease is cost effective. It should be an integral part of any plan for long-term control of asthma. The modified Patient Enablement Instrument (mPEI) is an easily administered questionnaire that was adapted in the United Kingdom to measure patient enablement in asthma, but its applicability in Portugal is not known. Validity and reliability of questionnaires should be tested before use in settings different from those of the original version. The purpose of this study was to test the applicability of the mPEI to Portuguese asthma patients after translation and cross-cultural adaptation, and to verify the structural validity, internal consistency and reproducibility of the instrument. The mPEI was translated to Portuguese and back translated to English. Its content validity was assessed by a debriefing interview with 10 asthma patients. The translated instrument was then administered to a random sample of 142 patients with persistent asthma. Structural validity and internal consistency were assessed. For reproducibility analysis, 86 patients completed the instrument again 7 days later. Item-scale correlations and exploratory factor analysis were used to assess structural validity. Cronbach's alpha was used to test internal consistency, and the intra-class correlation coefficient was used for the analysis of reproducibility. All items of the Portuguese version of the mPEI were found to be equivalent to the original English version. There were strong item-scale correlations that confirmed construct validity, with a one component structure and good internal consistency (Cronbach's alpha >0.8) as well as high test-retest reliability (ICC=0.85). The mPEI showed sound psychometric properties for the evaluation of enablement in patients with asthma making it a reliable instrument for use in research and clinical practice in Portugal. Further studies are needed to confirm its responsiveness.
Development and validation of the short-form Adolescent Health Promotion Scale.
Chen, Mei-Yen; Lai, Li-Ju; Chen, Hsiu-Chih; Gaete, Jorge
2014-10-26
Health-promoting lifestyle choices of adolescents are closely related to current and subsequent health status. However, parsimonious yet reliable and valid screening tools are scarce. The original 40-item adolescent health promotion (AHP) scale was developed by our research team and has been applied to measure adolescent health-promoting behaviors worldwide. The aim of our study was to examine the psychometric properties of a newly developed short-form version of the AHP (AHP-SF) including tests of its reliability and validity. The study was conducted in nine middle and high schools in southern Taiwan. Participants were 814 adolescents randomly divided into two subgroups with equal size and homogeneity of baseline characteristics. The first subsample (calibration sample) was used to modify and shorten the factorial model while the second subsample (validation sample) was utilized to validate the result obtained from the first one. The psychometric testing of the AHP-SF included internal reliability of McDonald's omega and Cronbach's alpha, convergent validity, discriminant validity, and construct validity with confirmatory factor analysis (CFA). The results of the CFA supported a six-factor model and 21 items were retained in the AHP-SF with acceptable model fit. For the discriminant validity test, results indicated that adolescents with lower AHP-SF scores were more likely to be overweight or obese, skip breakfast, and spend more time watching TV and playing computer games. The AHP-SF also showed excellent internal consistency with a McDonald's omega of 0.904 (Cronbach's alpha 0.905) in the calibration group. The current findings suggest that the AHP-SF is a valid and reliable instrument for the evaluation of adolescent health-promoting behaviors. Primary health care providers and clinicians can use the AHP-SF to assess these behaviors and evaluate the outcome of health promotion programs in the adolescent population.
Verloo, Henk; Desmedt, Mario; Morin, Diane
2017-09-01
To evaluate two psychometric properties of the French versions of the Evidence-Based Practice Beliefs and Evidence-Based Practice Implementation scales, namely their internal consistency and construct validity. The Evidence-Based Practice Beliefs and Evidence-Based Practice Implementation scales developed by Melnyk et al. are recognised as valid, reliable instruments in English. However, no psychometric validation for their French versions existed. Secondary analysis of a cross sectional survey. Source data came from a cross-sectional descriptive study sample of 382 nurses and other allied healthcare providers. Cronbach's alpha was used to evaluate internal consistency, and principal axis factor analysis and varimax rotation were computed to determine construct validity. The French Evidence-Based Practice Beliefs and Evidence-Based Practice Implementation scales showed excellent reliability, with Cronbach's alphas close to the scores established by Melnyk et al.'s original versions. Principal axis factor analysis showed medium-to-high factor loading scores without obtaining collinearity. Principal axis factor analysis with varimax rotation of the 16-item Evidence-Based Practice Beliefs scale resulted in a four-factor loading structure. Principal axis factor analysis with varimax rotation of the 17-item Evidence-Based Practice Implementation scale revealed a two-factor loading structure. Further research should attempt to understand why the French Evidence-Based Practice Implementation scale showed a two-factor loading structure but Melnyk et al.'s original has only one. The French versions of the Evidence-Based Practice Beliefs and Evidence-Based Practice Implementation scales can both be considered valid and reliable instruments for measuring Evidence-Based Practice beliefs and implementation. The results suggest that the French Evidence-Based Practice Beliefs and Evidence-Based Practice Implementation scales are valid and reliable and can therefore be used to evaluate the effectiveness of organisational strategies aimed at increasing professionals' confidence in Evidence-Based Practice, supporting its use and implementation. © 2017 John Wiley & Sons Ltd.
Karimi, Fatemeh Zahra; Alesheikh, Aytay; Pakravan, Soheila; Abdollahi, Mahbubeh; Damough, Mozhdeh; Anbaran, Zahra Khosravi; Farahani, Leila Amiri
2017-10-01
In medical sciences, commitment to lifelong learning has been expressed as an important element. Today, due to the rapid development of medical information and technology, lifelong learning is critical for safe medical care and development in medical research. JeffSPLL is one of the scales for measuring lifelong learning among the staff of medical sciences that has never been used in Iran. The aim of the present study was to determine the factor structure and reliability of the Persian version of JeffSPLL among Persian-speaking staff of universities of medical sciences in Iran. This study was a cross-sectional study, methodologically, that was conducted in 2012-2013. In this study, 210 staff members of Birjand University of Medical Sciences were selected. Data collection tool was the Persian version of JeffSPLL. To investigate the factor structure of this tool, confirmatory factor analysis was used and to evaluate the model fit, goodness-of-fit indices, root mean square error of approximation (RMSEA), the ratio of chi-square to the degree of freedom associated with it, comparative fit index (CFI), and root mean square residual (RMR) were used. To investigate the reliability of tool, Cronbach's alpha was employed. Data analysis was conducted using LISREL8.8 and SPSS 20 software. Confirmatory factor analysis showed that RMSEA was close to 0.1, and CFI and GFI were close to one. Therefore, four-factor model was appropriate. Cronbach's alpha was 0.92 for the whole tool and it was between 0.82 and 0.89 for subscales. The present study verified the four-factor structure of the 19-item Persian version of JeffSPLL that included professional learning beliefs and motivation, scholarly activities, attention to learning opportunities, and technical skills in information seeking among the staff. In addition, this tool has acceptable reliability. Therefore, it was appropriate to assess lifelong learning in the Persian-speaking staff population.
Ibrahim, Ahmed K; Kelly, Shona J; Challenor, Emily C; Glazebrook, Cris
2010-12-10
It is thought that depressive disorders will be the second leading cause of disability worldwide by 2020. Recently, there is a steady increase in the number of university students diagnosed and treated as depression patients. It can be assumed that depression is a serious mental health problem for university students because it affects all age groups of the students either younger or older equally. The current study aims to establish the reliability and validity of the Zagazig Depression scale in a UK sample. The study was a cross-sectional online survey. A sample of 133 out of 275 undergraduate students from a range of UK Universities in the academic year 2008-2009, aged 20.3 ± 6.3 years old were recruited. A modified back translated version of Zagazig Depression scale was used. In order to validate the Zagazig Depression scale, participants were asked to complete the Patient Health Questionnaire. Statistical analysis includes Kappa analysis, Cronbach's alpha, Spearman's correlation analysis, and Confirmatory Factor analysis. Using the recommended cut-off of Zagazig Depression scale for possible minor depression it was found that 30.3% of the students have depression and higher percentage was identified according to the Patient Health Questionnaire (37.4%). Females were more depressed. The mean ZDS score was 8.3 ± 4.2. Rates of depression increase as students get older. The reliability of The ZDS was satisfactory (Cronbach's alpha was .894). For validity, ZDS score was strongly associated with PHQ, with no significant difference (p-value > 0.05), with strong positive correlation (r = +.8, p-value < 0.01). The strong, significant correlation between the PHQ and ZDS, along with high internal consistency of the ZDS as a whole provides evidence that ZDS is a reliable measure of depressive symptoms and is promising for the use of the translated ZDS in a large-scale cross-culture study.
A new principle for the standardization of long paragraphs for reading speed analysis.
Radner, Wolfgang; Radner, Stephan; Diendorfer, Gabriela
2016-01-01
To investigate the reliability, validity, and statistical comparability of long paragraphs that were developed to be equivalent in construction and difficulty. Seven long paragraphs were developed that were equal in syntax, morphology, and number and position of words (111), with the same number of syllables (179) and number of characters (660). For validity analyses, the paragraphs were compared with the mean reading speed of a set of seven sentence optotypes of the RADNER Reading Charts (mean of 7 × 14 = 98 words read). Reliability analyses were performed by calculating the Cronbach's alpha value and the corrected total item correlation. Sixty participants (aged 20-77 years) read the paragraphs and the sentences (distance 40 cm; font: Times New Roman 12 pt). Test items were presented randomly; reading length was measured with a stopwatch. Reliability analysis yielded a Cronbach's alpha value of 0.988. When the long paragraphs were compared in pairwise fashion, significant differences were found in 13 of the 21 pairs (p < 0.05). In two sequences of three paragraphs each and in eight pairs of paragraphs, the paragraphs did not differ significantly, and these paragraph combinations are therefore suitable for comparative research studies. The mean reading speed was 173.34 ± 24.01 words per minute (wpm) for the long paragraphs and 198.26 ± 28.60 wpm for the sentence optotypes. The maximum difference in reading speed was 5.55 % for the long paragraphs and 2.95 % for the short sentence optotypes. The correlation between long paragraphs and sentence optotypes was high (r = 0.9243). Despite good reliability and equivalence in construction and degree of difficulty, a statistically significant difference in reading speed can occur between long paragraphs. Since statistical significance should be dependent only on the persons tested, either standardizing long paragraphs for statistical equality of reading speed measurements or increasing the number of presented paragraphs is recommended for comparative investigations.
Cheong, A T; Tong, S F; Sazlina, S G
2015-01-01
Hill-Bone compliance to high blood pressure therapy scale (HBTS) is one of the useful scales in primary care settings. It has been tested in America, Africa and Turkey with variable validity and reliability. The aim of this paper was to determine the validity and reliability of the Malay version of HBTS (HBTS-M) for the Malaysian population. HBTS comprises three subscales assessing compliance to medication, appointment and salt intake. The content validity of HBTS to the local population was agreed through consensus of expert panel. The 14 items used in the HBTS were adapted to reflect the local situations. It was translated into Malay and then back-translated into English. The translated version was piloted in 30 participants. This was followed by structural and predictive validity, and internal consistency testing in 262 patients with hypertension, who were on antihypertensive agent(s) for at least 1 year in two primary healthcare clinics in Kuala Lumpur, Malaysia. Exploratory factor analyses and the correlation between HBTS-M total score and blood pressure were performed. The Cronbach's alpha was calculated accordingly. Factor analysis revealed a three-component structure represented by two components on medication adherence and one on salt intake adherence. The Kaiser-Meyer-Olkin statistic was 0.764. The variance explained by each factors were 23.6%, 10.4% and 9.8%, respectively. However, the internal consistency for each component was suboptimal with Cronbach's alpha of 0.64, 0.55 and 0.29, respectively. Although there were two components representing medication adherence, the theoretical concepts underlying each concept cannot be differentiated. In addition, there was no correlation between the HBTS-M total score and blood pressure. HBTS-M did not conform to the structural and predictive validity of the original scale. Its reliability on assessing medication and salt intake adherence would most probably to be suboptimal in the Malaysian primary care setting.
Development of the Seasonal Migrant Agricultural Worker Stress Scale in Sanliurfa, Southeast Turkey.
Simsek, Zeynep; Ersin, Fatma; Kirmizitoprak, Evin
2016-01-01
Stress is one of the main causes of health problems, especially mental disorders. These health problems cause a significant amount of ability loss and increase cost. It is estimated that by 2020, mental disorders will constitute 15% of the total disease burden, and depression will rank second only after ischemic heart disease. Environmental experiences are paramount in increasing the liability of mental disorders in those who constantly face sustained high levels of stress. The objective of this study was to develop a stress scale for seasonal migrant agricultural workers aged 18 years and older. The sample consisted of 270 randomly selected seasonal migrant agricultural workers. The average age of the participants was 33.1 ± 14, and 50.7% were male. The Cronbach alpha coefficient and test-retest methods were used for reliability analyses. Although the factor analysis was performed for the structure validity of the scale, the Kaiser-Meyer-Olkin coefficient and Bartlett test were used to determine the convenience of the data for the factor analysis. In the reliability analyses, the Cronbach alpha coefficient of internal consistency was calculated as .96, and the test-retest reliability coefficient was .81. In the exploratory factor analysis for validity of the scale, four factors were obtained, and the factors represented workplace physical conditions (25.7% of the total variance), workplace psychosocial and economic factors (19.3% of the total variance), workplace health problems (15.2% of the total variance), and school problems (10.1% of the total variance). The four factors explained 70.3% of the total variance. As a result of the expert opinions and analyses, a stress scale with 48 items was developed. The highest score to be obtained from the scale was 144, and the lowest score was 0. The increase in the score indicates the increase in the stress levels. The findings show that the scale is a valid and reliable assessment instrument that can be used in epidemiological research and planning interventions.
Asadi-Lari, Mohsen; Ahmadi Pishkuhi, Mahin; Almasi-Hashiani, Amir; Safiri, Saeid; Sepidarkish, Mahdi
2015-07-01
Developing a tool for measuring patient's needs is a vital step in the process of cancer treatment and research. In recent years, the European Organization for Research and Treatment of Cancer (EORTC) made a questionnaire to measure cancer patients' received information. Since validity and reliability of any instrument should be evaluated in the new environment and culture, the aim of this study was to assess the validity and reliability of the EORTC QLQ-INFO25 in Iranian cancer patients. One hundred seventy-three patients with different stages of cancer filled questionnaire EORTC QLQ-INFO25, EORTC QLQ-C30, and EORTC IN-PATSAT32. Twenty-five patients answered the questionnaire twice at an interval of 2 weeks. Reliability and validity of the questionnaire was measured by Cronbach's alpha, interclass correlation, test retest, inter-rater agreement (IRA), and exploratory factorial analyses. Using a conservative approach, the IRA for the overall relevancy and clarity of the tool was 87/86% and 83.33%, respectively. Overall appropriateness and clarity were 94.13 and 91.87%, respectively. Overall integrity of the instrument was determined to be 85%. Cronbach's alpha coefficients for all domains and total inventory were top 70 and 90%, respectively. Interclass correlation index ranges between 0.708 and 0.965. Exploratory factorial analyses demonstrate six fields suitable for instrument. Correlation between areas of the questionnaires EORTC QLQ-INFO25 and EORTC in-Patsat32 represents the convergent validity of the questionnaire. Also, results show a standard divergent validity in all domains of the questionnaire (Rho <0.3). Low correlation between the areas of the questionnaires EORTC QLQ-INFO25 and EORTC QLQ-C30 (<0.3) demonstrates the divergence validity of the questionnaire. The results showed that Persian version of the questionnaire EORTC QLQ-INFO25 is a reliable and valid instrument for measuring the perception of information in cancer patients.
Nagpal, Jitender; Kumar, Arvind; Kakar, Sonia; Bhartia, Abhishek
2010-05-01
To develop a reliable and valid quality of life questionnaire for Indian patients with diabetes. A draft of 75 questions was prepared on the basis of expert opinion, focus group discussions, review of existing literature and detailed semi-structured interviews of patients with diabetes with the intention of including all aspects of diabetes-specific and quality of life considered relevant by patients and care providers to enable constrict validity. A Stage 2 questionnaire was then prepared with 13 domains and 54 items (questions) after expert panel review for obvious irrelevance and duplication of issues. It was administered to 150 participants visiting a diabetes center at New Delhi. Factor analysis was done using principal component method with varimax rotation. Reliability analysis was done by calculating Cronbach's Alpha. For evaluating concordant validity the questionnaire was co-administered with DQL-CTQ to 30 participants. The discriminant validity of the questionnaire was tested using 't' test for metabolic control, co-morbidities, insulin use and gender. Using principal component method 8 domains were identified on the basis of an apriori hypothesis and the scree plot. These 8 domains explained 49.9% of the total variation. 34 items (questions) were selected to represent these domains on the basis of extraction communality, factor loading, inter-item and item-total correlations. The final questionnaire has an Overall Cronbach's Alpha value of 0.894 (subscale- 0.55 to 0.85) showing high internal consistency. The questionnaire showed good concordance (product moment correlation 0.724; p = 0.001; subscale correlation - 0.457 to 0.779) with the DQL-CTQ. The overall standardized questionnaire score showed good responsiveness to metabolic control and co-morbidities establishing discriminant validity. The final version of questionnaire with 8 domains and 34 items is a reliable and valid tool for assessment of quality of life of Indian patients with diabetes.
Rusli, B N; Amrina, K; Trived, S; Loh, K P; Shashi, M
2017-10-01
The 21-item English version of the Depression Anxiety Stress Scale (DASS-21) has been proposed as a method for assessing self-perceived depression, anxiety and stress over the past week in various clinical and nonclinical populations. Several Malay versions of the DASS-21 have been validated in various populations with varying success. One particular Malay version has been validated in various occupational groups (such as nurses and automotive workers) but not among male clinic outpatient attendees in Malaysia. To validate the Malay version of the DASS-21 (Malay-DASS-21) among male outpatient clinic attendees in Johor. A validation study with a random sample of 402 male respondents attending the outpatient clinic of a major public outpatient clinic in Johor Bahru and Segamat was carried out from January to March 2016. Construct validity of the Malay-DASS-21 was examined using Exploratory Factor Analysis (KMO = 0.947; Bartlett's test of sphericity is significant, p<0.001) through Principal Component Analysis and orthogonal (varimax) rotation with Kaiser Normalization to confirm the psychometric properties of the Malay-DASS- 21 and the internal consistency reliability using Cronbach's alpha. Construct validity of the Malay-DASS-21 based on eigenvalues and factor loadings to confirm the three factor structure (depression, anxiety, and stress) was acceptable. The internal consistency reliability of the factor construct was very impressive with Cronbach's alpha values in the range of 0.837 to 0.863. The present study showed that the Malay- DASS-21 has acceptable psychometric construct and high internal consistency reliability to measure self-perceived depression, anxiety and stress over the past week in male outpatient clinic attendees in Johor. Further studies are necessary to revalidate the Malay-DASS-21 across different populations and cultures, and using confirmatory factor analyses.
Validity of the posttraumatic stress disorders (PTSD) checklist in pregnant women.
Gelaye, Bizu; Zheng, Yinnan; Medina-Mora, Maria Elena; Rondon, Marta B; Sánchez, Sixto E; Williams, Michelle A
2017-05-12
The PTSD Checklist-civilian (PCL-C) is one of the most commonly used self-report measures of PTSD symptoms, however, little is known about its validity when used in pregnancy. This study aims to evaluate the reliability and validity of the PCL-C as a screen for detecting PTSD symptoms among pregnant women. A total of 3372 pregnant women who attended their first prenatal care visit in Lima, Peru participated in the study. We assessed the reliability of the PCL-C items using Cronbach's alpha. Criterion validity and performance characteristics of PCL-C were assessed against an independent, blinded Clinician-Administered PTSD Scale (CAPS) interview using measures of sensitivity, specificity and receiver operating characteristics (ROC) curves. We tested construct validity using exploratory and confirmatory factor analytic approaches. The reliability of the PCL-C was excellent (Cronbach's alpha =0.90). ROC analysis showed that a cut-off score of 26 offered optimal discriminatory power, with a sensitivity of 0.86 (95% CI: 0.78-0.92) and a specificity of 0.63 (95% CI: 0.62-0.65). The area under the ROC curve was 0.75 (95% CI: 0.71-0.78). A three-factor solution was extracted using exploratory factor analysis and was further complemented with three other models using confirmatory factor analysis (CFA). In a CFA, a three-factor model based on DSM-IV symptom structure had reasonable fit statistics with comparative fit index of 0.86 and root mean square error of approximation of 0.09. The Spanish-language version of the PCL-C may be used as a screening tool for pregnant women. The PCL-C has good reliability, criterion validity and factorial validity. The optimal cut-off score obtained by maximizing the sensitivity and specificity should be considered cautiously; women who screened positive may require further investigation to confirm PTSD diagnosis.
Rushton, Paula W; Smith, Emma M; Miller, William C; Kirby, R Lee; Daoust, Geneviève
2018-01-31
The aim of this study was to evaluate the internal consistency, test-retest reliability and responsiveness of the Self-Efficacy in Assessing, Training and Spotting manual wheelchair skills (SEATS-M) and Self-Efficacy in Assessing, Training and Spotting power wheelchair skills (SEATS-P). A 2-week test-retest design was used with a convenience sample of occupational and physical therapists who worked at a provincial rehabilitation centre (inpatient and outpatient services). Sixteen participants completed the SEATS-M and 18 participants completed the SEATS-P. For the SEATS-M assessment, training, spotting and documentation sections, Cronbach's alpha coefficients ranged from 0.90 to 0.97, the 2-week intraclass correlation coefficients (ICC 1,1 ) ranged from 0.81 to 0.95, the standard error of measurements (SEM) ranged from 5.06 to 8.70 and the smallest real differences (SRD) ranged from 6.24 to 8.18. For the SEATS-P assessment, training, spotting and documentation sections, Cronbach's alpha coefficients ranged from 0.83 to 0.92, the ICCs ranged from 0.72 to 0.86, the SEMs ranged from 4.54 to 8.91 and the SRDs ranged from 5.90 to 8.27. There is preliminary evidence that both the SEATS-M and the SEATS-P have high internal consistency, good test-retest reliability and support for responsiveness. These tools can be used in evaluating clinician self-efficacy with assessing, training, spotting and documenting wheelchair skills included on the Wheelchair Skills Test. Implications for Rehabilitation There is preliminary evidence that the SEATS-M and SEATS-P are reliable and responsive outcome measures that can be used to evaluate the self-efficacy of clinicians to administer the Wheelchair Skills Program. Measurement of clinicians' self-efficacy in this area of practice may enable an enhanced understanding of the areas in which clinicians lack self-efficacy, thereby informing the development of improved knowledge translation interventions.
Caçola, Priscila M; Gabbard, Carl; Montebelo, Maria I L; Santos, Denise C C
2015-06-01
Affordances in the home environment may play a significant role in infant motor development. The purpose of this study was to further develop and validate the Affordances in the Home Environment for Motor Development-Infant Scale (AHEMD-IS), an inventory that measures the quantity and quality of motor affordances in the home. A cross-sectional study was conducted to evaluate criteria for content validity, reliability, internal consistency, floor and ceiling effects, and interpretability of the instrument. A pilot version of the inventory with 5 dimensions was used for expert panel analysis and administered to parents of infants (N=419). Data were analyzed with Cronbach alpha, intraclass correlation coefficients (ICCs), ceiling and floor effects, and item and dimension interpretability analyses for creation of a scoring system with descriptive categories for each dimension and total score. Average agreement among the expert panel was 95% across all evaluation criteria. Cronbach alpha values with the 41-item scale ranged between .639 and .824 for the separate dimensions, with a total value of .824 (95% confidence interval [95% CI]=.781, .862). The ICC values were .990 for interrater reliability and .949 for intrarater reliability. There was a ceiling effect on 3 questions for the Inside Space dimension and on 3 questions for the Variety of Stimulation dimension. These results demonstrated the need for reduction in total items (from 41 to 35) and the combination of space dimensions. After removal of questions, internal consistency was .766 (95% CI=.729, .800) for total score. Overall assessment categories were created as: less than adequate, moderately adequate, adequate, and excellent. The inventory does not determine specific use (time, frequency) of affordances in the home, and it does not account for infants' out-of-home activities. The AHEMD-IS is a reliable and valid instrument to assess affordances in the home environment that promote infant motor development. © 2015 American Physical Therapy Association.
Reliability and validity of the new Tanaka B Intelligence Scale scores: a group intelligence test.
Uno, Yota; Mizukami, Hitomi; Ando, Masahiko; Yukihiro, Ryoji; Iwasaki, Yoko; Ozaki, Norio
2014-01-01
The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2 ± 0.7 years) residing in a juvenile detention home; reliability was assessed using Cronbach's alpha coefficient, and concurrent validity was assessed using the one-way analysis of variance intraclass correlation coefficient. Moreover, receiver operating characteristic analysis for screening for individuals who have a deficit in intellectual function (an FIQ<70) was performed. In addition, stratum-specific likelihood ratios for detection of intellectual disability were calculated. The Cronbach's alpha for the new Tanaka B Intelligence Scale IQ (BIQ) was 0.86, and the intraclass correlation coefficient with FIQ was 0.83. Receiver operating characteristic analysis demonstrated an area under the curve of 0.89 (95% CI: 0.85-0.96). In addition, the stratum-specific likelihood ratio for the BIQ≤65 stratum was 13.8 (95% CI: 3.9-48.9), and the stratum-specific likelihood ratio for the BIQ≥76 stratum was 0.1 (95% CI: 0.03-0.4). Thus, intellectual disability could be ruled out or determined. The present results demonstrated that the new Tanaka B Intelligence Scale score had high reliability and concurrent validity with the Wechsler Intelligence Scale for Children-Third Edition score. Moreover, the post-test probability for the BIQ could be calculated when screening for individuals who have a deficit in intellectual function. The new Tanaka B Intelligence Test is convenient and can be administered within a variety of settings. This enables evaluation of intellectual development even in settings where performing intelligence tests have previously been difficult.
Gergana, Kodjebacheva; Coleman, Anne L.; Ensrud, Kristine E.; Cauley, Jane A.; Yu, Fei; Stone, Katie L.; Pedula, Kathryn L.; Hochberg, Marc C.; Mangione, Carol M.
2010-01-01
Purpose To test the reliability and validity of questionnaires shortened from the National Eye Institute 25-item Vision Function Questionnaire (NEI VFQ-9 and NEI VFQ-8). Design A cross-sectional multi-center cohort study. Methods Reliability was assessed by Cronbach alpha coefficients. Validity was evaluated by studying the association of vision-targeted quality-of-life composite scores with objective visual function measurements. Study population: A total of 5,482 women between the ages of 65 and 100 years participated in the Year-10 clinic visit in the Study of Osteoporotic Fractures (SOF). A total of 3,631 women with complete data were included in the visual acuity (VA) and visual field (VF) analysis of the NEI VFQ-9, which is defined for those who care to drive. and 5,311 in the analysis of the NEI VFQ-8. To assess differences in prevalent eye diseases, which were ascertained for a random sample of SOF participants, 853 and 1,237 women were included in the NEI VFQ-9 and the NEI VFQ-8 analyses, respectively. Results Cronbach alpha coefficient for the NEI VFQ-9 scale was 0.83 and that of the NEI VFQ-8 was 0.84. Using both questionnaires, women with VA worse than 20/40 had lower composite scores compared to those with VA 20/40 or better (p<0.001). Participants with mild, moderate, and severe binocular VF loss had lower composite scores compared to those with no binocular VF loss (p<0.001).Compared to women without chronic eye diseases in both eyes, women with at least one chronic eye disease in at least one eye had lower composite scores. Conclusions Both questionnaires showed high reliability across items and validity with respect to clinical markers of eye disease Future research should compare the properties of these shortened surveys to those of the NEI VFQ-25. PMID:20103058
Sudore, Rebecca L.; Stewart, Anita L.; Knight, Sara J.; McMahan, Ryan D.; Feuz, Mariko; Miao, Yinghui; Barnes, Deborah E.
2013-01-01
Introduction Advance directives have traditionally been considered the gold standard for advance care planning. However, recent evidence suggests that advance care planning involves a series of multiple discrete behaviors for which people are in varying stages of behavior change. The goal of our study was to develop and validate a survey to measure the full advance care planning process. Methods The Advance Care Planning Engagement Survey assesses “Process Measures” of factors known from Behavior Change Theory to affect behavior (knowledge, contemplation, self-efficacy, and readiness, using 5-point Likert scales) and “Action Measures” (yes/no) of multiple behaviors related to surrogate decision makers, values and quality of life, flexibility for surrogate decision making, and informed decision making. We administered surveys at baseline and 1 week later to 50 diverse, older adults from San Francisco hospitals. Internal consistency reliability of Process Measures was assessed using Cronbach's alpha (only continuous variables) and test-retest reliability of Process and Action Measures was examined using intraclass correlations. For discriminant validity, we compared Process and Action Measure scores between this cohort and 20 healthy college students (mean age 23.2 years, SD 2.7). Results Mean age was 69.3 (SD 10.5) and 42% were non-White. The survey took a mean of 21.4 minutes (±6.2) to administer. The survey had good internal consistency (Process Measures Cronbach's alpha, 0.94) and test-retest reliability (Process Measures intraclass correlation, 0.70; Action Measures, 0.87). Both Process and Action Measure scores were higher in the older than younger group, p<.001. Conclusion A new Advance Care Planning Engagement Survey that measures behavior change (knowledge, contemplation, self-efficacy, and readiness) and multiple advance care planning actions demonstrates good reliability and validity. Further research is needed to assess whether survey scores improve in response to advance care planning interventions and whether scores are associated with receipt of care consistent with one's wishes. PMID:24039772
Faik, A; Benbouazza, K; Amine, B; Maaroufi, H; Bahiri, R; Lazrak, N; Aboukal, R; Hajjaj-Hassouni, N
2008-05-01
The aim of this study is to assess the reliability and validity of the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) in Moroccan patients with knee osteoarthritis. The WOMAC was translated and back translated to and from dialectal Arabic, pre-tested and reviewed by a committee following the Guillemin criteria. The Moroccan version of the WOMAC was administered twice during a 24-48 h interval to 71 Moroccan patients with symptomatic knee osteoarthritis, fulfilling the revised criteria of the American College of Rheumatology. The test-retest reliability was assessed using intra-class correlation coefficient, and the Bland and Altman method. Internal consistency was assessed by Cronbach's alpha coefficient. Construct validity was tested by correlating the WOMAC subscales with visual analogic scale (VAS) of pain, VAS of handicap, maximum distance walked and clinical characteristics. The Moroccan version of the WOMAC showed good reliability, with ICC values of the three dimensions: pain, stiffness and physical function being 0.80, 0.77 and 0.89, respectively. Bland and Altman analysis showed that means of differences did not differ significantly from 0 and that no systematic trend was observed. Internal consistency with Cronbach's alpha for pain was found to be 0.76, and its equivalents for stiffness and physical function subscales were evaluated at 0.76, 0.90, respectively. Construct validity showed statistically significant correlation with all WOMAC subscales and VAS of pain (rho=0.38, 0.42, 0.63 respectively, P<0.01). Correlation between VAS handicap (rho=0.38 P<0.001) and maximum distance walked (rho=-0.40, P<0.01) was observed with physical function subscale. There was no correlation between age, duration of disease, BMI and severity of pain and physical function in knee OA. The Moroccan version of the WOMAC is a comprehensible, reliable, and valid instrument to measure outcome in patients with knee OA.
Li, D H; Wang, W; Li, X; Gao, Y L; Liu, D H; Liu, D L; Xu, W D
2017-01-01
The International Hip Outcome Tool (iHOT-33) is a questionnaire designed for young, active patients with hip disorders. It has proven to be a highly reliable and valid questionnaire. The main purpose of our study was to adapt the iHOT-33 questionnaire into simplified Chinese and to assess its psychometric properties in Chinese patients. The iHOT-33 was cross culturally adapted into Chinese and 138 patients completed the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the EuroQol-5D (EQ-5D), and the Chinese version of the iHOT-33(SC-iHOT-33) pre- or postoperatively within 6 months' follow-up. The Cronbach's alpha, intraclass correlation coefficient (ICC), Pearson's correlation coefficient (r), effect size (ES), and standardized response mean (SRM) were calculated to assess the reliability, validity, and responsiveness of the SC-iHOT-33, respectively. Total Cronbach's alpha was 0.965, which represented excellent internal consistency of the SC-iHOT-33. The ICC ranges from 0.866 to 0.929, which shows excellent test-retest reliability. The subscales of SC-iHOT-33 had the highest correlation coefficient (r = 0.812) with the physical function subscales of the WOMAC, as well as good correlation between the social/emotional subscale of the SC-iHOT-33 and the EQ-5D (r = 0.740, r = 0.743). No floor or ceiling effects were found. The ES and SRM values indicated good responsiveness of 2.44 and 2.67, respectively. The SC-iHOT-33 questionnaire is reliable, valid, and responsive for the evaluation of young, Chinese, active patients with hip disorders. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Cross-cultural Adaptation of the "Functional Activities Questionnaire - FAQ" for use in Brazil
Sanchez, Maria Angélica dos Santos; Correa, Pricila Cristina Ribeiro; Lourenço, Roberto Alves
2011-01-01
Objective The aim of this paper was to present the results of the first stage of cross-cultural adaptation of the Functional Activities Questionnaire (FAQ). Methods The tool was subjected to translation and re-translation, and the test-retest reliability of a proposed version for use in Brazil was analyzed. Results Of the 548 questionnaire respondents, a convenience sample of 68 informants was selected for retesting. Internal consistency was measured by Cronbach's alpha (0.95) while test-retest reliability was assessed using intra-class correlation (0.97). The findings have shown that FAQ is brief - averaging seven minutes to apply, easily understood and has good intra-rater test-retest reliability. Conclusion Our results suggest this adapted version of the FAQ is a reliable and stable tool which may be useful for assessing function in Brazilian elderly. Notwithstanding, the version should be subjected to further analysis with the aim of reaching functional equivalence. PMID:29213759
Developing scale for colleague solidarity among nurses in Turkey.
Uslusoy, Esin Cetinkaya; Alpar, Sule Ecevit
2013-02-01
There is a need for an appropriate instrument to measure colleague solidarity among nurses. This study was carried out to develop a Colleague Solidarity of Nurses' Scale (CSNS). This study was planned to be descriptive and methodological. The CSNS examined content validity, construct validity, test-retest reliability and internal consistency reliability. The trial form of the CSNS, which was composed of 44 items, was given to 200 nurses, followed by validity and reliability analyses. Following the analyses, 21 items were excluded from the scale, leaving an attitude scale made up of 23 items. Factor analysis of the data showed that the scale has a three sub-factor structure: emotional solidarity, academic solidarity and negative opinions about solidarity. The Cronbach's alpha reliability of the whole scale was 0.80. This study provides evidence that the CSNS possesses robust solidarity among nurses. © 2013 Wiley Publishing Asia Pty Ltd.
Togari, Taisuke; Yamazaki, Yoshihiko; Koide, Syotaro; Miyata, Ayako
2006-01-01
In community and workplace health plans, the Perceived Health Competence Scale (PHCS) is employed as an index of health competency. The purpose of this research was to examine the reliability and validity of a modified Japanese PHCS. Interviews were sought with 3,000 randomly selected Japanese individuals using a two-step stratified method. Valid PHCS responses were obtained from 1,910 individuals, yielding a 63.7% response rate. Reliability was assessed using Cronbach's alpha coefficient (henceforth, alpha) to evaluate internal consistency, and by employing item-total correlation and alpha coefficient analyses to assess the effect of removal of variables from the model. To examine content validity, we assessed the correlation between the PHCS score and four respondent attribute characteristics, that is, sex, age, the presence of chronic disease, and the existence of chronic disease at age 18. The correlation between PHCS score and commonly employed healthy lifestyle indices was examined to assess construct validity. General linear model statistical analysis was employed. The modified Japanese PHCS demonstrated a satisfactory alpha coefficient of 0.869. Moreover, reliability was confirmed by item-total correlation and alpha coefficient analyses after removal of variables from the model. Differences in PHCS scores were seen between individuals 60 years and older, and younger individuals. These with current chronic disease, or who had had a chronic disease at age 18, tended to have lower PHCS scores. After controlling for the presence of current or age 18 chronic disease, age, and sex, significant correlations were seen between PHCS scores and tobacco use, dietary habits, and exercise, but not alcohol use or frequency of medical consultation. This study supports the reliability and validity, and hence supports the use, of the modified Japanese PHCS. Future longitudinal research is needed to evaluate the predictive power of modified Japanese PHCS scores, to examine factors influencing the development of perceived health competence, and to assess the effects of interventions on perceived health competence.
Pereira, Fernanda Maria Vieira; Lam, Simon Ching; Gir, Elucir
2017-03-02
this study aimed to carry of the cultural adaptation and to evaluate the reliability of the Compliance with Standard Precautions Scale (CSPS) for nurses in Brazil. the adaptation process entailed translation, consensus among judges, back-translation, semantic validation and pretest. The reliability was evaluated by internal consistency (Cronbach alpha) and stability (test-retest). The instrument was administered to a sample group of 300 nurses who worked in a large hospital located in the city of São Paulo/SP, Brazil. through the semantic validation, the items from the scale were considered understandable and deemed important for the nurse´s clinical practice. The CSPS Brazilian Portuguese version (CSPS-PB) revealed excellent interpretability. The Cronbach`s alpha was 0.61 and the intraclass correlation coefficient was 0.85. the initial study showed that CSPS-PB is appropriate to assess compliance with standard precautions among nurses in Brazil. The reliability was considered acceptable. Furhter study is necessary to evaluate its comprehensive psychometric properties. adaptar culturalmente y evaluar la confiabilidad de la Compliance with Standard Precautions Scale (CSPS) para enfermeros en Brasil. el proceso de adaptación abarcó la traducción, consenso entre jueces, retrotraducción, validación semántica y pretest. La confiabilidad fue evaluada mediante la consistencia interna (alfa de Cronbach) y estabilidad (test-retest). El instrumento fue administrado a una muestra de 300 enfermeros actuantes en un gran hospital ubicado en la ciudad de São Paulo/SP, Brasil. a través de la validación semántica, los ítems de la escala fueron considerados comprensibles e importantes para la práctica clínica enfermera. La versión en portugués de Brasil de la CSPS (CSPS-PB) reveló excelente posibilidad de interpretación. El alfa de Cronbach correspondió a 0.61 y el coeficiente de correlación intraclase fue 0.85. el estudio inicial mostró que la CSPS-PB es apropiada para evaluar el cumplimiento con las precauciones estándar entre enfermeros en Brasil. La confiabilidad fue considerada aceptable. Son necesarios estudios adicionales para evaluar sus propiedades psicométricas. o objetivo deste estudo foi realizar a adaptação cultural e avaliar a confiabilidade da versão brasileira da Compliance with Standard Precautions (CSPS) entre enfermeiros no Brasil. o processo de adaptação incluiu tradução, consenso entre juízes, retro-tradução, validação semântica e pré-teste. A confiabilidade foi verificada de acordo com a consistência interna (alfa de Cronbach) e a estabilidade usando teste-reteste. A escala foi aplicada em uma amostra de 300 enfermeiros que trabalhavam num hospital de grande porte na cidade de São Paulo, SP, Brasil. a validação semântica revelou que os itens da escala eram compreensíveis e foram considerados relevantes para a prática clínica dos enfermeiros. A versão brasileira da escala (CSPS-PB) revelou excelente nível de compreensão. O alfa de Cronbach foi 0,61 e o coeficiente de correlação intraclasse foi 0,85. Este estudo inicial mostrou que a CSPS-PB é apropriada para avaliar adesão às precauções padrão entre enfermeiros brasileiros. A confiabilidade foi considerada aceitável. Mais estudos são necessários para avaliar suas propriedades psicométricas.
Good practices in normal childbirth: reliability analysis of an instrument by Cronbach’s Alpha 1
Gottems, Leila Bernarda Donato; Carvalho, Elisabete Mesquita Peres De; Guilhem, Dirce; Pires, Maria Raquel Gomes Maia
2018-01-01
ABSTRACT Objectives: to analyze the internal consistency of the evaluation instrument of the adherence to the good practices of childbirth and birth care in the professionals, through Cronbach’s Alpha Coefficient for each of the dimensions and for the total instrument. Method: this is a descriptive and cross-sectional study performed in obstetric centers of eleven public hospitals in the Federal District, with a questionnaire applied to 261 professionals who worked in the delivery care. Results: The study was attended by 261 professionals, 42.5% (111) nurses and 57.5% (150) physicians. The reliability evaluation of the instrument by the Cronbach Alfa resulted in 0.53, 0.78 and 0.76 for dimensions 1, 2 and 3, after debugging that resulted in the exclusion of 11 items. Conclusions: the instrument obtained Cronbach’s alpha of 0.80. There is a need for improvement in the items of dimension 1 that refer to attitudes, knowledge, and practices of the organization of the network of care to gestation, childbirth, and birth. However, it can be applied in the way it is used to evaluate practices based on scientific evidence of childbirth care. PMID:29791667
Kickett-Tucker, C S; Christensen, D; Lawrence, D; Zubrick, S R; Johnson, D J; Stanley, F
2015-10-24
In Australia, there is little empirical research of the racial identity of Indigenous children and youth as the majority of the current literature focuses on adults. Furthermore, there are no instruments developed with cultural appropriateness when exploring the identity and self-esteem of the Australian Aboriginal population, especially children. The IRISE_C (Racial Identity and Self-Esteem of children) inventory was developed to explore the elements of racial identity and self-esteem of urban, rural and regional Aboriginal children. This paper describes the development and validation of the IRISE_C instrument with over 250 Aboriginal children aged 8 to 12 years. A pilot of the IRISE C instrument was combined with individual interviews and was undertaken with 35 urban Aboriginal children aged 8-12 years. An exploratory factor analysis was performed to refine the survey and reduce redundant items in readiness for the main study. In the main study, the IRISE C was employed to 229 Aboriginal children aged 6-13 years across three sites (rural, regional and urban) in Western Australia. An exploratory factor analysis using Principal axis factoring was used to assess the fit of items and survey structure. A confirmatory factor analysis was then employed using LISREL (diagonally weighted least squares) to assess factor structures across domains. Internal consistency and reliability of subscales were assessed using Cronbach's co-efficient alpha. The pilot testing identified two key concepts - children's knowledge of issues related to their racial identity, and the importance, or salience, that they attach to these issues. In the main study, factor analyses showed two clear factors relating to: Aboriginal culture and traditions; and a sense of belonging to an Aboriginal community. Principal Axis Factoring of the Knowledge items supported a 2-factor solution, which explained 38.7% of variance. Factor One (Aboriginal culture) had a Cronbach's alpha of 0.835; Factor 2 (racial identity) had a Cronbach's alpha of 0.800, thus demonstrating high internal reliability of the scales. The IRISE_C has been shown to be a valid instrument useful of exploring the development of racial identity of Australian Aboriginal children across the 8-12 year old age range and across urban, rural and regional geographical locations.
Huang, Wenhao; Chapman-Novakofski, Karen M
2017-01-01
Background The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. Objective The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps’ educational quality and technical functionality. Methods Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Results Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no significant change over time (P>.05) for all but skill development (P=.001). Construct reliability was good for items assessing age appropriateness of apps for children, teens, and a general audience. In addition, construct reliability was acceptable for assessing app appropriateness for various target audiences (Cronbach alpha >.70). For the 5 main factors, ICC (1,k) was >.80, with a P value of <.05. When 15 nutrition professionals evaluated one app, ICC (2,15) was .98, with a P value of <.001 for all 7 constructs when the modifiable items were specified for adults seeking weight loss support. Conclusions Our preliminary effort shows that AQEL is a valid, reliable instrument for evaluating nutrition apps’ qualities for clinical interventions by nutrition clinicians, educators, and researchers. Further efforts in validating AQEL in various contexts are needed. PMID:29079554
Sfendla, Anis; Laita, Meriame; Nejjar, Basma; Souirti, Zouhayr; Touhami, Ahami Ahmed Omar; Senhaji, Meftaha
2018-05-01
The extensive accessibility to smartphones in the last decade raises the concerns of addictive behavior patterns toward these technologies worldwide and in developing countries, and Arabic ones in particular. In an area of stigmatized behavior such as Internet and smartphone addiction, the hypothesis extends to whether there is a reliable instrument that can assess smartphone addiction. To our knowledge, no scale in Arabic language is available to assess maladaptive behavior associated with smartphone use. This study aims to assess the factorial validity and internal reliability of the Arabic Smartphone Addiction Scale (SAS) and Smartphone Addiction Scale-Short Version (SAS-SV) in a Moroccan surveyed population. Participants (N = 440 and N = 310) completed an online survey, including SAS, SAS-SV, and questions about sociodemographic status. Factor analysis results showed six factors with factor loading ranging from 0.25 to 0.99 for SAS. Reliability, based on Cronbach's alpha, was excellent (α = 0.94) for this instrument. The SAS-SV showed one factor (unidimensional construct), and internal reliability was in the good range with an alpha coefficient of (α = 0.87). The prevalence of excessive users was 55.8 percent with highest symptom prevalence reported for tolerance and preoccupation. This study proved factor validity of the Arabic SAS and SAS-SV instruments and confirmed their internal reliability.
[Rosenberg self-esteem scale: validation in a representative sample of Chilean adults].
Rojas-Barahona, Cristian A; Zegers, Beatriz; Förster, Carla E
2009-06-01
Self-esteem is positively associated to the well being of people and could be a good mental health indicator. To determine the reliability and validity of the Rosenberg Self-esteem Scale in a Chilean adult sample. The instrument was applied to 473 subjects living in the Metropolitan Region of Santiago, evenly distributed according to gender, age, educational level and income. The Neugarten Life Satisfaction index (LSI-A) was also applied to the sample. Cronbach's alpha for reliability of the scale was 0.754. There was no gender bias and factor analysis grouped items into two factors (5 positive and 5 negative). The instrument had a correlation of 0.455 with the LSI-A. The Rosenberg Self-esteem Scale meets the criteria for validity and reliability of a quality instrument to measure self-esteem in Chile.
Reliability and validity of the Euthanasia Attitude Scale (EAS) for Hong Kong medical doctors.
Tang, Wai-Kiu; Mak, Kwok-Kei; Kam, Philip Ming-Ho; Ho, Joanna Wing-Kiu; Chan, Denise Che-Ying; Suen, To-Lam; Lau, Michael Chak-Kwan; Cheng, Adrian Ka-Chun; Wan, Yuen-Ting; Wan, Ho-Yan; Hussain, Assad
2010-08-01
This study aimed to examine the reliability and validity of the Euthanasia Attitude Scale (EAS) in Hong Kong medical doctors. A total of 107 medical doctors (61.7% men) participated in a survey at clinical settings in 2008. The 21-item EAS was used to assess their attitudes toward euthanasia. The mean (standard deviation) and median of the EAS were 63.60 (60.31) and 63.00. Total EAS scores correlated well with ''Ethical Considerations,'' ''Practical Considerations,'' and ''Treasuring Life'' (Spearman rho =.37-.96, P < .001) but not ''Naturalistic Beliefs.'' The construct validity of the 3-factor model was appropriate (Kaiser-Meyer-Olkin [KMO] value = 0.90) and showed high internal consistency (Cronbach alpha =.79-.92). Euthanasia Attitude Scale may be a reliable and valid measure for assessing the attitudes toward euthanasia in medical professionals.
Sousa, Pedro; Gaspar, Pedro; Vaz, Daniela C; Gonzaga, Sílvia; Dixe, M Anjos
2015-04-01
Individual lifestyles have emerged as valuable health constructs. This study aims to psychometrically test the Portuguese (European) version of the Health-Promoting Lifestyle Profile-II. After an adequate linguistic and cultural adaptation of the Health-Promoting Lifestyle Profile-II scale, their psychometric properties were assessed (N = 889) by Cronbach's alpha and confirmatory factor analysis. Results showed an adequate fit to a 52-item, six-factor structure. A global alpha of .925 was obtained. The Portuguese version demonstrated good validity and reliability in a wide adult sample, and can thus be applied to the Portuguese population. This instrument is useful as an evaluation tool for health-promoting lifestyles and as an instrument for testing the effectiveness of health-promoting programs. © 2014 NANDA International, Inc.
Measuring Certified Registered Nurse Anesthetist Organizational Climate: Instrument Adaptation.
Boyd, Donald; Poghosyan, Lusine
2017-08-01
No tool exists measuring certified registered nurse anesthetist (CRNA) organizational climate. The study's purpose is to adapt a validated tool to measure CRNA organizational climate. Content validity of the Certified Registered Nurse Anesthetist Organizational Climate Questionnaire (CRNA-OCQ) was established. Pilot testing was conducted to determine internal reliability consistency of the subscales. Experts rated the tool as content valid. The subscales had high internal consistency reliability (with respective Cronbach's alphas): CRNA-Anesthesiologist Relations (.753), CRNA-Physician Relations (.833), CRNA-Administration Relations (.895), Independent Practice (.830), Support for CRNA Practice (.683), and Professional Visibility (.772). Further refinement of the CRNA-OCQ is necessary. Measurement and assessment of CRNA organizational climate may produce evidence needed to improve provider and patient outcomes.
Mendez, Roberto Della Rosa; Rodrigues, Roberta Cunha Matheus; Cornélio, Marilia Estevam; Gallani, Maria Cecília Bueno Jayme; Godin, Gaston
2010-09-01
The aim of this study was to report the development and the analysis of content validity and reliability of the Psychosocial Determinants of Physical Activity among Coronary Heart Disease Patients Questionnaire, based on an extension of the Theory of Planned Behavior. In the content validity step, three experts evaluated the instrument which was, afterwards, pre-tested with five subjects in order to obtain a conceptually appropriate and easily understood instrument. Fifty-one patients participated in the evaluation of internal consistency of the reviewed instrument. Cronbach's alpha coefficients above 0.75 were observed for the constructs: Intention, Attitude, Subjective Norm, Self-efficacy and Habit. The new instrument demonstrated acceptable evidence of content validity and reliability.
Psychometric testing of the clinical nurse leader staff satisfaction instrument.
Spiva, LeeAnna; Hart, Patricia L; Wesley, Mary Lou; Gallagher, Erin; McVay, Frank; Waggoner, Jessica; Jarrell, Nicole; Threatt, Jamie L
2014-01-01
Patient care is changing rapidly with increased complexity of care, patient volumes, and financial constraints with rising health care costs and limited reimbursements. In response, the clinical nurse leader (CNL) role was developed. No appropriate instrument exists to measure staff satisfaction with the CNL role. This study describes the development and testing of an instrument designed to measure staff satisfaction with implementation of the CNL role. The psychometric properties and factor structure of the Clinical Nurse Leader Staff Satisfaction (CNLSS) instrument was examined. A 2-factor solution was discovered for the CNLSS. Cronbach's alpha coefficients were acceptable for the subscales and instrument. The CNLSS is a valid and reliable instrument. Future research should focus on establishing test-retest reliability and construct validity.
Development of a stress scale for pregnant women in the South Asian context: the A-Z Stress Scale.
Kazi, A; Fatmi, Z; Hatcher, J; Niaz, U; Aziz, A
2009-01-01
Stress in pregnancy can lead to low-birth-weight and preterm babies and to psychological consequences such as anxiety and depression during pregnancy and the puerperium. Previous scales to measure stress contain items that overlap with the symptoms of pregnancy. A stress scale was developed based on in-depth interviews with pregnant women in Pakistan. Construct validity, test-retest reliability and inter-rater reliability were carried out. Cronbach alpha was 0.82 for the 30 short-listed items, with item-total correlations of 0.2-0.8. Multidimensional scaling determined 2 dimensions: socioenvironmental hassles and chronic illnesses. This was the first scale developed for pregnant women based on stressors in a developing country in South Asia.
Hellweg, Stephanie; Schuster-Amft, Corina
2016-07-19
Agitation is frequently observed during early recovery after traumatic brain injury (TBI). Agitated behaviour often interferes with a goal-orientated rehabilitation and can be a substantial hindrance to therapy. Despite the relatively high occurance of agitation in TBI population there is no objective assessement in German (G) available. An existing scale with excellent psychometric properties is the "Agitated Behavior Scale (ABS)" developed by Corrigan in 1989. The aim of the study was to translate the Agitated Behavior Scale (ABS) into German (ABS-G) and investigate the inter- and intrarater reliability and internal consistency in patients with moderate to severe TBI. A formal nine-step translation and cross-cultural adaptation procedure (TCCA) was applied. Subsequently a prospective observational patient study was conducted. To examine the interrater reliability and internal consistency, two therapists rated 20 patients independently after a therapy session. This procedure was repeated twice on a weekly basis. The intrarater reliability was assessed through video recordings from three patients. Nine raters scored the demonstrated behaviour on the videotape with the ABS-G independently twice within one month. The inter- and intrarater reliability were evaluated with the Spearman rank correlation coefficient and the quadratic weighted kappa. The internal consistency was tested with Cronbach's alpha. Behaviour of 20 patients (18 males; mean age 41 ± 20.7; mean Functional Independence Measure (FIM) cognitive score on admission 7.1 ± 4.04; mean ABS-G score at first observation 17.3 ± 2.83) was assessed threefold. Interrater reliability yielded a correlation coefficient for ABS-G total score of all 60 paired observations of r s 0.845 and a weighted Kappa of 0.738. Intrarater reliability for ABS-G total score ranged between r s 0.719 and 0.953 and showed a weighted Kappa between 0.871 and 0.953. Cronbach's alpha indicated moderate internal consistency with 0.661. This study demonstrates that the ABS-G is a reliable instrument for evaluating agitation in patients with moderate to severe TBI. Hereby it would be possible to monitor agitation objectively and optimise the management of agitated patients according to international recommendations.
de Vente, Wieke; Majdandžić, Mirjana; Voncken, Marisol J; Beidel, Deborah C; Bögels, Susan M
2014-03-01
We developed a new version of the Social Phobia and Anxiety Inventory (SPAI) in order to have a brief instrument for measuring social anxiety and social anxiety disorder (SAD) with a strong conceptual foundation. In the construction phase, a set of items representing 5 core aspects of social anxiety was selected by a panel of social anxiety experts. The selected item pool was validated using factor analysis, reliability analysis, and diagnostic analysis in a sample of healthy participants (N = 188) and a sample of clinically referred participants diagnosed with SAD (N = 98). This procedure resulted in an abbreviated version of the Social Phobia Subscale of the SPAI consisting of 18 items (i.e. the SPAI-18), which correlated strongly with the Social Phobia Subscale of the original SPAI (both groups r = .98). Internal consistency and diagnostic characteristics using a clinical cut-off score > 48 were good to excellent (Cronbach's alpha healthy group = .93; patient group = .91; sensitivity: .94; specificity: .88). The SPAI-18 was further validated in a community sample of parents-to-be without SAD (N = 237) and with SAD (N = 65). Internal consistency was again excellent (both groups Cronbach's alpha = .93) and a screening cut-off of > 36 proved to result in good sensitivity and specificity. The SPAI-18 also correlated strongly with other social anxiety instruments, supporting convergent validity. In sum, the SPAI-18 is a psychometrically sound instrument with good screening capacity for social anxiety disorder in clinical as well as community samples. Copyright © 2013 Elsevier Ltd. All rights reserved.
Keilmann, Annerose; Konerding, Uwe; Oberherr, Constantin; Nawka, Tadeus
2016-12-01
Structural, neurological and muscular diseases can lead to impairments of articulation. These impairments can severely impact social life. To judge health status comprehensively, this impact must be adequately quantified. For this purpose, the articulation handicap index (AHI) has been developed. Psychometric analyses referring to this index are presented here. The AHI was completed by 113 patients who had undergone treatment of tumours of the head or neck. The patients also gave a general self-assessment of their impairments due to articulation problems. Furthermore, tumour size, tumour location and kind of therapy were recorded. Missing data were analysed and replaced by multiple imputation. Internal structure was investigated using principal component analysis (PCA); reliability using Cronbach's alpha. Validity was investigated by analysing the relationship between AHI and general self-assessment of impairments. Moreover, the relationships with tumour size, tumour location and kind of therapy were analysed. Only 0.12 % of the answers to the AHI were missing. The Scree test performed with the PCA results suggested one-dimensionality with the first component explaining 49.6 % of the item variance. Cronbach's alpha was 0.96. Kendall's tau between the AHI sum score and the general self-assessment was 0.69. The intervals of AHI sum scores for the self-assessment categories were determined with 0-13 for no, 14-44 for mild, 46-76 for moderate, and 77-120 for severe impairment. The AHI sum score did not systematically relate to tumour size, tumour location or kind of therapy. The results are evidence for high acceptance, reliability and validity.
Translation and validation of chronic liver disease questionnaire (CLDQ) in Tamil language.
Goel, Amit; Arivazhagan, Karunanithi; Sasi, Avani; Shanmugam, Vanathy; Koshi, Seleena; Pottakkat, Biju; Lakshmi, C P; Awasthi, Ashish
2017-05-01
Chronic liver disease questionnaire (CLDQ), a self-administered quality-of-life (QOL) instrument for chronic liver disease (CLD) patients, was originally developed in English language. We aimed to translate and validate CLDQ in Tamil language (CLDQ-T). CLDQ-T, prepared by two forward and two backward independent translations by four bilingual (Tamil and English) persons, and repeated iterative modifications, was validated in adult, native-Tamil patients with CLD. CLDQ-T was re-tested in some patients 2 weeks later. Convergent validity was assessed using Spearman's correlation, and discriminant validity by comparison with World Health Organization's brief QOL tool (WHOQOL-BREF). Reliability was assessed through internal consistency (Cronbach's alpha) and test-retest reliability (intra-class correlation). Cutoff used for statistical significance was p<0.05. The study included 126 patients (age: mean [SD] 46 years [12.5]; male 104; cause: alcohol 42%, HBV 25%, HCV 4%, cryptogenic 29%; CTP class A 47%, B 37%, and C 16%). In convergent validity, all domains except the "abdominal domain" showed significant correlation between CLDQ-T and WHOQOL-BREF. Patients with severe disease had lower scores for all domains of CLDQ-T except the "abdominal" domain, but not for any of the domains for WHOQOL-BREF. Overall Cronbach's alpha was 0.942, and more than 0.7 for all the individual domains except the "activity" domain. On retesting in 44 (35%) patients, intraclass correlation coefficient was 0.879 for the overall CLDQ-T score and >0.700 for individual domains. CLDQ-T was easily understood and showed good performance characteristics in assessing QOL in Tamil-speaking patients with CLD.
A validation study of public health knowledge, skills, social responsibility and applied learning.
Vackova, Dana; Chen, Coco K; Lui, Juliana N M; Johnston, Janice M
2018-06-22
To design and validate a questionnaire to measure medical students' Public Health (PH) knowledge, skills, social responsibility and applied learning as indicated in the four domains recommended by the Association of Schools & Programmes of Public Health (ASPPH). A cross-sectional study was conducted to develop an evaluation tool for PH undergraduate education through item generation, reduction, refinement and validation. The 74 preliminary items derived from the existing literature were reduced to 55 items based on expert panel review which included those with expertise in PH, psychometrics and medical education, as well as medical students. Psychometric properties of the preliminary questionnaire were assessed as follows: frequency of endorsement for item variance; principal component analysis (PCA) with varimax rotation for item reduction and factor estimation; Cronbach's Alpha, item-total correlation and test-retest validity for internal consistency and reliability. PCA yielded five factors: PH Learning Experience (6 items); PH Risk Assessment and Communication (5 items); Future Use of Evidence in Practice (6 items); Recognition of PH as a Scientific Discipline (4 items); and PH Skills Development (3 items), explaining 72.05% variance. Internal consistency and reliability tests were satisfactory (Cronbach's Alpha ranged from 0.87 to 0.90; item-total correlation > 0.59). Lower paired test-retest correlations reflected instability in a social science environment. An evaluation tool for community-centred PH education has been developed and validated. The tool measures PH knowledge, skills, social responsibilities and applied learning as recommended by the internationally recognised Association of Schools & Programmes of Public Health (ASPPH).
Validity evidence for the measurement of the strength of motivation for medical school.
Kusurkar, Rashmi; Croiset, Gerda; Kruitwagen, Cas; ten Cate, Olle
2011-05-01
The Strength of Motivation for Medical School (SMMS) questionnaire is designed to determine the strength of motivation of students particularly for medical study. This research was performed to establish the validity evidence for measuring strength of motivation for medical school. Internal structure and relations to other variables were used as the sources of validity evidence. The SMMS questionnaire was filled out by 1,494 medical students in different years of medical curriculum. The validity evidence for the internal structure was analyzed by principal components analysis with promax rotation. Validity evidence for relations to other variables was tested by comparing the SMMS scores with scores on the Academic Motivation Scale (AMS) and the exhaustion scale of Maslach Burnout Inventory-Student Survey (MBI-SS) for measuring study stress. Evidence for internal consistency was determined through the Cronbach's alpha for reliability. The analysis showed that the SMMS had a 3-factor structure. The validity in relations to other variables was established as both, the subscales and full scale scores significantly correlated positively with the intrinsic motivation scores and with the more autonomous forms of extrinsic motivation, the correlation decreasing and finally becoming negative towards the extrinsic motivation end of the spectrum. They also had significant negative correlations with amotivation scale of the AMS and exhaustion scale of MBI-SS. The Cronbach's alpha for reliability of the three subscales and full SMMS scores was 0.70, 0.67, 0.55 and 0.79. The strength of motivation for medical school has a three factor structure and acceptable validity evidence was found in our study.
Identifying key components for an effective case report poster: an observational study.
Willett, Lisa L; Paranjape, Anuradha; Estrada, Carlos
2009-03-01
Residents demonstrate scholarly activity by presenting posters at academic meetings. Although recommendations from national organizations are available, evidence identifying which components are most important is not. To develop and test an evaluation tool to measure the quality of case report posters and identify the specific components most in need of improvement. Faculty evaluators reviewed case report posters and provided on-site feedback to presenters at poster sessions of four annual academic general internal medicine meetings. A newly developed ten-item evaluation form measured poster quality for specific components of content, discussion, and format (5-point Likert scale, 1 = lowest, 5 = highest). Evaluation tool performance, including Cronbach alpha and inter-rater reliability, overall poster scores, differences across meetings and evaluators and specific components of the posters most in need of improvement. Forty-five evaluators from 20 medical institutions reviewed 347 posters. Cronbach's alpha of the evaluation form was 0.84 and inter-rater reliability, Spearman's rho 0.49 (p < 0.001). The median score was 4.1 (Q1 -Q3, 3.7-4.6)(Q1 = 25th, Q3 = 75th percentile). The national meeting median score was higher than the regional meetings (4.4 vs, 4.0, P < 0.001). We found no difference in faculty scores. The following areas were identified as most needing improvement: clearly state learning objectives, tie conclusions to learning objectives, and use appropriate amount of words. Our evaluation tool provides empirical data to guide trainees as they prepare posters for presentation which may improve poster quality and enhance their scholarly productivity.
[Validation of a questionnaire to evaluate patient safety in clinical laboratories].
Giménez Marín, Ángeles; Rivas-Ruiz, Francisco
2012-01-01
The aim of this study was to prepare, pilot and validate a questionnaire to evaluate patient safety in the specific context of clinical laboratories. A specific questionnaire on patient safety in the laboratory, with 62 items grouped into six areas, was developed, taking into consideration the diverse human and laboratory contextual factors which may contribute to producing errors. A pilot study of 30 interviews was carried out, including validity and reliability analyses using principal components factor analysis and Cronbach's alpha. Subsequently, 240 questionnaires were sent to 21 hospitals, followed by a test-retest of 41 questionnaires with the definitive version. The sample analyzed was composed of 225 questionnaires (an overall response rate of 80%). Of the 62 items initially assessed, 17 were eliminated due to non-compliance with the criteria established before the principal components factor analysis was performed. For the 45 remaining items, 12 components were identified, with an cumulative variance of 69.5%. In seven of the 10 components with two or more items, Cronbach's alpha was higher than 0.7. The questionnaire items assessed in the test-retest were found to be stable. We present the first questionnaire with sufficiently proven validity and reliability for evaluating patient safety in the specific context of clinical laboratories. This questionnaire provides a useful instrument to perform a subsequent macrostudy of hospital clinical laboratories in Spain. The questionnaire can also be used to monitor and promote commitment to patient safety within the search for continuous quality improvement. Copyright © 2011 SESPAS. Published by Elsevier Espana. All rights reserved.
Kunkel, S; Rosenqvist, U; Westerling, R
2009-02-01
To analyse whether the organisation of quality systems (structure, process, and outcome) is related to how these systems were implemented (implementation prerequisites, cooperation between managers and staff, and source of initiative). A questionnaire was developed, piloted and distributed to 600 hospital departments. Questions were included to reflect implementation prerequisites (adequate resources, competence, problem-solving capacity and high expectations), cooperative implementation, source of initiative (manager, staff and purchaser), structure (resources and administration), process (culture and cooperation) and outcome (goal evaluation and competence development). The adjusted response rate was 75%. Construct validity and reliability was assessed by confirmatory factor analysis, and Cronbach alpha scores were calculated. The relationships among the variables were analysed with structural equation modelling with LISREL. Implementation prerequisites were highly related to structure (0.51) and process (0.33). Cooperative implementation was associated with process (0.26) and outcome (0.34). High manager initiative was related to structure (0.19) and process (0.17). The numbers in parentheses can be interpreted as correlations. Construct validity was good, and reliability was excellent for all factors (Cronbach alpha>0.78). The model was a good representation of reality (model fit p value = 0.082). The implementation of organisationally demanding quality systems may require managers to direct and lead the process while assuring that their staff get opportunities to contribute to the planning and designing of the new system. This would correspond to a cooperative implementation strategy rather than to top-down or bottom-up strategies. The results of this study could be used to adjust implementation processes.
Development of the breast milk expression experience measure.
Flaherman, Valerie J; Gay, Barbara; Scott, Cheryl; Aby, Janelle; Stewart, Anita L; Lee, Kathryn A
2013-07-01
Exclusive breastfeeding provides optimal nutrition through 6 months. Recent research has shown that milk expression may affect breastfeeding duration. A woman's experience with milk expression might mediate the effect of milk expression on breastfeeding duration. The objective of this study was to develop a measure to evaluate women's experiences of expressing milk. Based on the available literature, we developed a brief measure of the Breast Milk Expression Experience (BMEE) assessing three dimensions: (1) social support for milk expression; (2) ease of learning how to express milk; and (3) personal experiences of milk expression. All items used 1-5 Likert scales, with higher scores indicating better experiences. We administered the items immediately after expression to 68 mothers who expressed milk post-partum. We evaluated this measure for reliability using Cronbach's alpha. Mothers completing the BMEE were 57% primiparous with 75% vaginal births. The BMEE demonstrated appropriate reliability with a Cronbach's alpha of 0.703 for the summary index and 0.719-0.763 for social support, learning experience and personal experience subscales. The BMEE also indicated good predictive validity; of the six mothers who had a mean score <3 on the 11-item scale post-partum, two (33.3%) were expressing breast milk at 1 month, compared with 37 (80.4%) of the 46 mothers who had a mean score ≥3 on the 11-item scale post-partum (P = 0.012). The BMEE is a promising measure of milk expression experience in this population. Use of this measure may allow improved understanding of women's experiences expressing milk. © 2012 John Wiley & Sons Ltd.
Lehmann, Vicky; Makine, Ceylan; Karşıdağ, Cagatay; Kadıoğlu, Pinar; Karşıdağ, Kubilay; Pouwer, François
2011-07-26
Depression is a common co-morbid health problem in patients with diabetes that is underrecognised. Current international guidelines recommend screening for depression in patients with diabetes. Yet, few depression screening instruments have been validated for use in this particular group of patients. Aim of the present study was to investigate the psychometric properties of the Turkish version of the Centre for Epidemiologic Studies Depression Scale (CES-D) in patients with type 2 diabetes. A sample of 151 Turkish outpatients with type 2 diabetes completed the CES-D, the World Health Organization-Five Well-Being Index (WHO-5), and the Problem Areas in Diabetes scale (PAID). Explanatory factor analyses, various correlations and Cronbach's alpha were investigated to test the validity and reliability of the CES-D in Turkish diabetes outpatients. The original four-factor structure proposed by Radloff was not confirmed. Explanatory factor analyses revealed a two-factor structure representing two subscales: (1) depressed mood combined with somatic symptoms of depression and (2) positive affect. However, one item showed insufficient factor loadings. Cronbach's alpha of the total score was high (0.88), as were split-half coefficients (0.77-0.90). The correlation of the CES-D with the WHO-5 was the strongest (r = -0.70), and supported concurrent validity. The CES-D appears to be a valid measure for the assessment of depression in Turkish diabetes patients. Future studies should investigate its sensitivity and specificity as well as test-retest reliability.
Buss, Tomasz; Kruk, Agnieszka; Wiśniewski, Piotr; Modlinska, Aleksandra; Janiszewska, Justyna; Lichodziejewska-Niemierko, Monika
2014-10-01
Multidimensional questionnaires estimating cancer-related fatigue (CRF) as a symptom cluster or a clinical syndrome primarily have been used and validated in English-speaking populations. However, cultural issues and language peculiarities can affect CRF assessment The main aims of this study were to evaluate the psychometric properties of the Polish version of the Multidimensional Fatigue Inventory-20 (MFI-20) and to deliver to clinicians a multidimensional tool for CRF assessment in Polish-speaking patients with cancer. After forward-backward translation procedures, the Polish version of MFI-20 was administered to 340 cancer patients. The Polish MFI-20 was appraised in terms of acceptability, reliability, and validity. Internal consistency was assessed by calculating Cronbach's alpha coefficients. Structural validity was evaluated with confirmatory factor analysis. The translated MFI-20 was well accepted; 90% of subjects fully completed the questionnaire. The overall Cronbach's alpha coefficient was 0.9, ranging from 0.57 to 0.81. All correlation coefficients among Numeric Rating Scale-fatigue, fatigue-related items from the European Organization for Research and Treatment of Cancer Quality of Life Core-30 questionnaire, and the MFI--20 were statistically significant (P < 0.001). Confirmatory factor analysis demonstrated good structural validity and revealed only three dimensions in the Polish version of the MFI-20-physical and mental fatigue as well as reduced motivation. The Polish version of the MFI-20 is well accepted by patients, reliable, and a valid instrument to assess CRF in Polish cancer patients. Copyright © 2014 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Modak, Isitri; Sexton, J Bryan; Lux, Thomas R; Helmreich, Robert L; Thomas, Eric J
2007-01-01
Provider attitudes about issues pertinent to patient safety may be related to errors and adverse events. We know of no instruments that measure safety-related attitudes in the outpatient setting. To adapt the safety attitudes questionnaire (SAQ) to the outpatient setting and compare attitudes among different types of providers in the outpatient setting. We modified the SAQ to create a 62-item SAQ-ambulatory version (SAQ-A). Patient care staff in a multispecialty, academic practice rated their agreement with the items using a 5-point Likert scale. Cronbach's alpha was calculated to determine reliability of scale scores. Differences in SAQ-A scores between providers were assessed using ANOVA. Of the 409 staff, 282 (69%) returned surveys. One hundred ninety (46%) surveys were included in the analyses. Cronbach's alpha ranged from 0.68 to 0.86 for the scales: teamwork climate, safety climate, perceptions of management, job satisfaction, working conditions, and stress recognition. Physicians had the least favorable attitudes about perceptions of management while managers had the most favorable attitudes (mean scores: 50.4 +/- 22.5 vs 72.5 +/- 19.6, P < 0.05; percent with positive attitudes 18% vs 70%, respectively). Nurses had the most positive stress recognition scores (mean score 66.0 +/- 24.0). All providers had similar attitudes toward teamwork climate, safety climate, job satisfaction, and working conditions. The SAQ-A is a reliable tool for eliciting provider attitudes about the ambulatory work setting. Attitudes relevant to medical error may differ among provider types and reflect behavior and clinic operations that could be improved.
Moen, Vegard Pihl; Drageset, Jorunn; Eide, Geir Egil; Klokkerud, Mari; Gjesdal, Sturla
2017-02-01
The World Health Organization Disability Assessment Schedule (WHODAS) 2.0 is a generic instrument to assess disability covering six domains. The purpose of this study was to investigate the potential of the instrument for monitoring disability in specialized somatic rehabilitation by testing reliability, construct validity and responsiveness of WHODAS 2.0, Norwegian version, among patients with various health conditions. For taxonomy, terminology and definitions, the Consensus-based Standards for the Selection of Health Measurement Instruments were followed. Reproducibility was investigated by the intra-class correlation coefficient (ICC) in a randomly selected sample. Internal consistency was assessed by Cronbach's alpha. Construct validity was evaluated by correlations between WHODAS 2.0 and the Medical Outcomes Study 36-item Short Form, and fit of the hypothesized structure using confirmatory factor analysis (CFA). Responsiveness was evaluated in another randomly selected sample by testing a priori formulated hypotheses. Nine hundred seventy patients were included in the study. Reproducibility and responsiveness were evaluated in 53 and 104 patients, respectively. The ICC for the WHODAS 2.0 domains ranged from 0.63 to 0.84 and was 0.87 for total score. Cronbach's alpha for domains ranged from 0.75 to 0.94 and was 0.93 for total score. For construct validity, 6 of 12 expected correlations were confirmed and CFA did not achieve satisfactory fit indices. For responsiveness, 3 of 8 hypotheses were confirmed. The Norwegian version of WHODAS 2.0 showed moderate to satisfactory reliability and moderate validity in rehabilitation patients. However, the present study indicated possible limitations in terms of responsiveness.
Sun, Ning; Li, Qiu-Jie; Lv, Dong-Mei; Lu, Gui-Zhi; Lin, Ping; An, Xue-Mei
2014-10-01
The present study was conducted to evaluate the psychometric properties of a newly adapted Chinese version of an instrument designed to measure structural empowerment among staff nurses. Structural empowerment has been shown to be important to nurses in Western cultures, but its importance in China is unknown. A convenience sample of 650 staff nurses was selected from six hospitals in Harbin, China. After linguistic adaptation using the forward-backward translation method, the 19-item Conditions of Work Effectiveness Questionnaire-II (CWEQ-II-CV) was answered by participants. Content validity, Cronbach's alpha, item-to-total correlation and exploratory factor analysis were used to assess the reliability and validity of the translated instrument. In the factor analysis, a six-factor solution was found to be reasonable with the sub-dimensions of structural empowerment that included support (three items), resources (three items), information (three items), opportunity (three items), formal power (three items) and informal power (four items). Cronbach's alpha coefficient for the total instrument was 0.92 and ranged from 0.68 to 0.86 in the six subscales. The item-to-total correlation coefficients ranged from 0.48 to 0.80. The findings also gave support for content validity. Evidence was found to support the reliability and validity of the CWEQ-II-CV scale that measures the quality of the work environment for nurses from a structural empowerment perspective. The translated version of CWEQ-II-CV can provide an effective evaluation tool for structural empowerment in the Chinese nursing workplace. © 2013 John Wiley & Sons Ltd.
Development of a resilience scale for Thai substance-dependent women: A mixed methods approach.
Sakunpong, Nanchatsan; Choochom, Oraphin; Taephant, Nattasuda
2016-08-01
The purpose of this study was to develop a resilience scale based on the experiences of substance-dependent women in Thailand and evaluate its validity and reliability. A sequential exploratory mixed methods design was employed as the main methodology to develop the resilience scale according to the results from qualitative data by analyzing focus group discussions of 13 participants. Then, the scale was administered to 252 substance-dependent women from four substance-treatment centers. The psychometric properties were explored with an index of item objective congruence (IOC), Pearson correlation, second-order confirmatory factor analysis and Cronbach's alpha coefficient to estimate the quantitative data. The qualitative results showed that resilience is defined by three themes: individual, family and community factors, consisted of 13 different categories. The quantitative results also revealed that all 71 items in the resilience scale passed the IOC criteria, convergence and construct validity. The goodness-of-fit indices demonstrated that the resilience model was consistent with the empirical data. (Chi-square=74.28, df=59, p-value=0.08, RMSEA=0.03, SRMR=0.04, NNFI=0.99, CFI=0.99, GFI=0.96). The internal consistency, assessed by a Cronbach's alpha score of 0.92, can be interpreted as demonstrating high reliability. Furthermore, the structure of the resilience scale was confirmed by the available resilience literature. This study can help clinicians gain a more comprehensive understanding regarding the complex process of resilience among substance-dependent women and aid them in providing these women with the appropriate interventions. Copyright © 2015 Elsevier B.V. All rights reserved.
Honda, Michitaka; Wakita, Takafumi; Onishi, Yoshihiro; Nunobe, Souya; Miura, Akinori; Nishigori, Tatsuto; Kusanagi, Hiroshi; Yamamoto, Takatsugu; Boddy, Alexander; Fukuhara, Shunichi
2015-12-01
Patients who have undergone esophagectomy or gastrectomy have certain dietary limitations because of changes to the alimentary tract. This study attempted to develop a psychometric scale, named "Esophago-Gastric surgery and Quality of Dietary life (EGQ-D)," for assessment of impact of upper gastrointestinal surgery on diet-targeted quality of life. Using qualitative methods, the study team interviewed both patients and surgeons involved in esophagogastric cancer surgery, and we prepared an item pool and a draft scale. To evaluate the scale's psychometric reliability and validity, a survey involving a large number of patients was conducted. Items for the final scale were selected by factor analysis and item response theory. Cronbach's alpha was used for assessment of reliability, and correlations with the short form (SF)-12, esophagus and stomach surgery symptom scale (ES(4)), and nutritional indicators were analyzed to assess the criterion-related validity. Through multifaceted discussion and the pilot study, a draft questionnaire comprising 14 items was prepared, and a total of 316 patients were enrolled. On the basis of factor analysis and item response theory, six items were excluded, and the remaining eight items demonstrated strong unidimensionality for the final scale. Cronbach's alpha was 0.895. There were significant associations with all the subscale scores for SF-12, ES(4), and nutritional indicators. The EGQ-D scale has good contents and psychometric validity and can be used to evaluate disease-specific instrument to measure diet-targeted quality of life for postoperative patients with esophagogastric cancer.
Xia, Hao-Zhi; Gao, Lei; Wang, Yang; Song, Hui; Shi, Bao-Xin
2017-11-01
To develop a Meaning in Life Scale for cancer patients in Chinese version and to test the validity and reliability. Meaning in life is a protective factor of psychological well-being and is negatively related to depression and demoralisation among cancer patients. The existing scales measuring meaning in life are mostly designed in English and there is no scale designed for Chinese cancer patients based on Chinese cultural background. Process of instrument development and psychometric evaluation were used. Items were generated from literature review and a focus group interview. Delphi technique was used to test the content validity. Item analysis and exploratory factor analysis were performed with data from 251 cancer patients. The internal consistency of the scale was tested by Cronbach's alpha. A 25-item Meaning in Life Scale in Chinese version with five domains was developed. The five factors explained 62·686% of the variance. The Cronbach's alpha for the total scale was 0·897. The Meaning in Life Scale in Chinese version has acceptable internal consistency reliability and good content validity and acceptable construct validity. The content of the scale reflected the attitudes of cancer patients towards meaning in life based on Chinese cultural background. The Chinese version of Meaning in Life Scale for Cancer Patients appears to be a new scale to assess meaning in life among Chinese cancer patients exactly and the concept of meaning in life presented in this scale provides new ideas of meaning intervention in routine clinical practice. © 2016 John Wiley & Sons Ltd.
Alamanou, G Despoina; Balokas, A Sotirios; Fotos, V Nikolaos; Patiraki, Elisabeth; Brokalaki, Hero
2016-02-01
The aim of this study was to validate the translated in Greek Cassileth's Information Styles Questionnaire (ISQ). It was a cross-sectional study. The sample consisted of one hundred and nine adult patients diagnosed with cancer, attending the oncology outpatient department (outpatients) or being hospitalized (inpatients), from January 2013 to September 2013, in one general hospital in Athens. Two instruments were used: The Control Preference Scale (CPS), an assessment tool to measure decision-making preferences of cancer patients and ISQ to assess the information needs of patients. Exploratory factor analysis (EFA) was carried out to evaluate construct validity of the ISQ. The internal consistency of subscales was analyzed with Cronbach's alpha and the association of demographics and clinical variables with the ISQ was explored using linear regression analysis. Sixty one (56%) patients were males. The mean age was 65.5 (SD = 11.9) years. Two dimensions of the ISQ were revealed. Cronbach's alpha was 0.92 for "Disease and treatment" dimension (12 of 17 items of the questionnaire) and 0.89 for "Psychological" dimension (5 of 17 items of the questionnaire). Statistical analysis showed that the patients' preferred decision making roles were associated with the ISQ dimensions. Also, age, sex, diagnosis, educational level and the existence of metastasis were associated with the score of "Disease and treatment" dimension. All the scales of ISQ, exceeded the minimum reliability standard of 0.70. The results showed that the Greek ISQ is a reliable and valid tool for identifying the information needs of cancer patients. Copyright © 2015 Elsevier Ltd. All rights reserved.
Development and psychometric testing of the satisfaction with Cultural Simulation Experience Scale.
Courtney-Pratt, Helen; Levett-Jones, Tracy; Lapkin, Samuel; Pitt, Victoria; Gilligan, Conor; Van der Riet, Pamela; Rossiter, Rachel; Jones, Donovan; Everson, Naleya
2015-11-01
Decreasing the numbers of adverse health events experienced by people from culturally diverse backgrounds rests, in part, on the ability of education providers to provide quality learning experiences that support nursing students in developing cultural competence, an essential professional attribute. This paper reports on the implementation and evaluation of an immersive 3D cultural empathy simulation. The Satisfaction with Cultural Simulation Experience Scale used in this study was adapted and validated as the first stage of this study. Exploratory factor analysis and confirmatory factor analysis were undertaken to investigate the psychometric properties of the scale using two randomly-split sub-samples. Cronbach's Alpha was used to examine internal consistency reliability. Descriptive statistics were used for analysis of mean satisfaction scores and qualitative comments to open-ended questions were analysed and coded. A purposive sample (n = 497) of second of nursing students participated in the study. The overall Cronbach's alpha for the scale was 0.95 and each subscale demonstrated high internal consistency: 0.92; 0.92; 0.72 respectively. The mean satisfaction score was 4.64 (SD 0.51) out of a maximum of 5 indicating a high level of participant satisfaction with the simulation. Three factors emerged from qualitative analysis: "Becoming culturally competent", "Learning from the debrief" and "Reflecting on practice". The cultural simulation was highly regarded by students. Psychometric testing of the Satisfaction with Cultural Simulation Experience Scale demonstrated that it is a reliable instrument. However, there is room for improvement and further testing in other contexts is therefore recommended. Copyright © 2015 Elsevier Ltd. All rights reserved.
Yılmaz, Emel; Eser, Erhan; Şekuri, Cevad; Kültürsay, Hakan
2011-08-01
The purpose of this study was to describe the psychometric properties of the Myocardial Infarction Dimensional Assessment Scale (MIDAS). This is a methodological cultural adaptation study. The MIDAS consists of 35-items covering seven domains: physical activity, insecurity, emotional reaction, dependency, diet, concerns over medication, and side effects which are rated on a five-point Likert scale from 1: never to 5:always. The highest score of MIDAS is 100.Quality of life (QOL) decreases as the score of scale increases. Overall 185 myocardial infarction (MI) patients were enrolled in this study. Cronbach alpha was used for the reliability analysis. The criterion validity, structural validity, and sensitivity analysis approach was used for validity analysis. New York Heart Association (NYHA) and the Canadian Cardiovascular Society Functional Classifications (CCSFC) for testing the criterion validity; SF-36 for construct validity testing of the Turkish version of the MIDAS were used. The range of Cronbach alpha values is 0.79-0.90 for seven domains of the scale. No problematic items were observed for the entire scale. Medication related domains of the MIDAS showed considerable floor effects (35.7%-22.7%). Confirmatory Factor analysis indicators [Comparative Fit Index (CFI) =0.95 and Root Mean Square Error of Approximation (RMSEA) =0.075] supported the construct validity of MIDAS. Convergent validity of the MIDAS was confirmed with correlation of SF-36 scale where appropriate. Criterion validity results was also satisfactory by comparing different stages of the NYHA and the CCSFC (p<0.05). Overall results revealed that Turkish version of the MIDAS is a reliable and valid instrument.
Smith, Sherilyn; Kogan, Jennifer R; Berman, Norman B; Dell, Michael S; Brock, Douglas M; Robins, Lynne S
2016-01-01
The ability to create a concise summary statement can be assessed as a marker for clinical reasoning. The authors describe the development and preliminary validation of a rubric to assess such summary statements. Between November 2011 and June 2014, four researchers independently coded 50 summary statements randomly selected from a large database of medical students' summary statements in virtual patient cases to each create an assessment rubric. Through an iterative process, they created a consensus assessment rubric and applied it to 60 additional summary statements. Cronbach alpha calculations determined the internal consistency of the rubric components, intraclass correlation coefficient (ICC) calculations determined the interrater agreement, and Spearman rank-order correlations determined the correlations between rubric components. Researchers' comments describing their individual rating approaches were analyzed using content analysis. The final rubric included five components: factual accuracy, appropriate narrowing of the differential diagnosis, transformation of information, use of semantic qualifiers, and a global rating. Internal consistency was acceptable (Cronbach alpha 0.771). Interrater reliability for the entire rubric was acceptable (ICC 0.891; 95% confidence interval 0.859-0.917). Spearman calculations revealed a range of correlations across cases. Content analysis of the researchers' comments indicated differences in their application of the assessment rubric. This rubric has potential as a tool for feedback and assessment. Opportunities for future study include establishing interrater reliability with other raters and on different cases, designing training for raters to use the tool, and assessing how feedback using this rubric affects students' clinical reasoning skills.
Yalin, Osman Özgür; Uludüz, Derya; Sungur, Mehmet Ali; Sart, Hande; Özge, Aynur
2017-09-01
Cutaneous allodynia is regarded as an expression of central sensitization in migraine. Although the gold standard is quantitative sensory testing, several practical assessment questionnaires have been developed to assess allodynia in migraine. We aimed to establish the first valid Turkish allodynia assessment questionnaire based on a 12-item allodynia symptom checklist and to evaluate the associated factors. The first part of the study included the translation and cultural adaptation of a Turkish version of the checklist. The Turkish version of the questionnaire was administered to 344 episodic and chronic migraine patients, who were chosen according to the International Classification of Headache Disorders -III beta criteria. The total checklist score showed excellent test-retest reliability (r=0.821). The internal consistency of the checklist was assessed using Cronbach alpha values and was found to be acceptable (Cronbach alpha for the checklist=0.767). Data analysis revealed that 10 items of the questionnaire adequately identified allodynic subjects. Cutaneous allodynia was present in 218 (63.4%) migraine patients. Allodynia was more prominent in patients experiencing migraine with aura (p=0.008) and in females (p<0.001). Multiple logistic regression analysis found that female gender, aura existence, longer headache duration, and higher attack frequency were the major determinants of cutaneous allodynia. Allodynia is common and has clinical significance in migraine; therefore, establishing a validated Turkish questionnaire for the assessment of allodynia was necessary. In this study, a Turkish version of the allodynia symptom checklist was validated and found to be convenient for the identification of allodynia in migraine patients.
Rohani, Hosein; Eslami, Ahmad Ali; Ghaderi, Arsalan; Jafari-Koshki, Tohid; Sadeghi, Erfan; Bidkhori, Mohammad; Raei, Mehdi
2016-01-01
Moderate increase in physical activity (PA) may be helpful in preventing or postponing the complications of type 2 diabetes mellitus (T2DM). The aim of this study was to assess the psychometric properties of a health action process approach (HAPA)-based PA inventory among T2DM patients. In 2015, this cross-sectional study was carried out on 203 participants recruited by convenience sampling in Isfahan, Iran. Content and face validity was confirmed by a panel of experts. The comments noted by 9 outpatients on the inventory were also investigated. Then,the items were administered to 203 T2DM patients. Construct validity was conducted using exploratory and structural equation modeling confirmatory factor analyses. Reliability was also assessed with Cronbach alpha and interclass correlation coefficient (ICC). Content validity was acceptable (CVR = 0.62, CVI = 0.89). Exploratory factor analysis extracted seven factors (risk- perception, action self-efficacy, outcome expectancies, maintenance self-efficacy, action and coping planning, behavioral intention, and recovery self-efficacy) explaining 82.23% of the variation. The HAPA had an acceptable fit to the observations (χ2 = 3.21, df = 3, P = 0.38; RMSEA = 0.06; AGFI = 0.90; PGFI = 0.12). The range of Cronbach alpha and ICC for the scales was about 0.63 to 0.97 and 0.862 to 0.988, respectively. The findings of the present study provided an initial support for the reliability and validity of the HAPA-based PA inventory among patients with T2DM.
Lacroix, Emilie; Deggouj, Naima; Salvaggio, Samuel; Wiener, Valérie; Debue, Michel; Edwards, Martin Gareth
2016-12-01
Vertigo patients frequently complain of emotional and associated cognitive problems, yet currently, there is no satisfactory questionnaire to measure these associated problems. In the present paper, we propose a new internet-based Neuropsychological Vertigo Inventory (NVI; French) that evaluates attention, memory, emotion, space perception, time perception, vision, and motor abilities. The questionnaire was created using four steps: (1) open interviews with patients suffering from vertigo; (2) semi-structured interviews with an analysis grid to quantify and define the various cognitive and emotional problems reported by the patients; (3) a first version of an internet questionnaire tested on 108 vertigo participants; and (4) the selection of subscale items using principal component analyses (PCA). From the development phase, the revised NVI was composed of seven subscales, each with four items (28 items). In the validation phase, Cronbach's alphas were performed on the revised NVI for total and each subscale score, and to test extreme groups validity, the analyses of covariance (ANCOVAs) taking into account age were performed between 108 vertigo and 104 non-vertigo participants. The Cronbach's alphas showed good to satisfactory coefficients for the total and for all subscale scores, demonstrating acceptable reliability. The extreme groups validity analyses (ANCOVAs) were reliable for the total scale and for four subscales. Supplementary analyses showed no effect of hearing difficulties and an inverse age effect for attention and emotion subscales, with reduced problems with increased age in the vertigo participants. The NVI provides a useful new questionnaire to determine cognitive and emotional neuropsychological complaints that are associated with vertigo.
Kitada, Masako; Musashi, Manabu; Kano, Masato
2011-08-01
To examine reliability and validity of Kano Test for Social Nicotine Dependence (KTSND), a scale assessing the psychosocial acceptability of smoking, and to develop a new version when validity or reliability of KTSND was not acceptable. We carried out a self-administered cross-sectional survey on undergraduate university students. The participants completed the KTSND, and supplemented three questions on the attitudes toward tobacco control policies and smoking states. Using daily smokers, we examined the relationship between the KTSND and Fagerström Test for Nicotine Dependence (FTND). In each study, we examined test-retest reliability and construct validity, discriminant and convergent validity, and factor validity. Although the KTSND had high internal consistency (Cronbach's a 0.82) and high test-retest reliability (r=0.72), the results of factor analysis were unacceptable; we expected three factors to be extracted, however, only two factors of "Overestimate of smoking usefulness" and "Allege smoking as a taste and/or culture" were extracted. Using the Kano's Test for Assessing Acceptability of Smoking (KTAAS), the new version of KTSND in which a question was replaced with another one, the third factor of "Neglect of harm of tobacco smoking" was extracted adding to the above-mentioned two. KTAAS had also both high internal consistency (Cronbach's alpha 0.82) and test-retest reliability (r=0.66). Overall, the KTSND and the KTAAS score differed according to smoking states, and the nonsmokers' scores were the lowest. The KTSND was a popular questionnaire in Japan, however, its validity assessed using factor analysis was not acceptable, while KTAAS had sufficient reliability and validity, and might assess the cognition and attitude affirming or accepting tobacco smoking among university students.
Standardization of the NEO-PI-3 in the Greek general population.
Fountoulakis, Konstantinos N; Siamouli, Melina; Moysidou, Stefania; Pantoula, Eleonora; Moutou, Katerina; Panagiotidis, Panagiotis; Kemeridou, Marina; Mavridou, Eirini; Loli, Efimia; Batsiari, Elena; Preti, Antonio; Tondo, Leonardo; Gonda, Xenia; Mobayed, Nisreen; Akiskal, Kareen; Akiskal, Hagop; Costa, Paul; McCrae, Robert
2014-01-01
The revised NEO Personality Inventory (NEO-PI-3) includes 240 items corresponding to the Big Five personality traits (Extraversion, Agreeableness, Conscientiousness, Neuroticism, and Openness to Experience) and subordinate dimensions (facets). It is suitable for use with adolescents and adults (12 years or older). The aim of the current study was to validate the Greek translation of the NEO-PI-3 in the general Greek population. The study sample included 734 subjects from the general Greek population of whom 59.4% were females and 40.6% males aged 40.80 ± 11.48. The NEO-PI-3 was translated into Greek and back-translated into English, and the accuracy of the translation was confirmed and established. The statistical analysis included descriptive statistics, confirmatory factorial analysis (CFA), the calculation of Cronbach's alpha, and the calculation of Pearson product-moment correlations. Sociodemographics groups were compared by ANOVA. Most facets had Cronbach's alpha above 0.60. Confirmatory factor analysis showed acceptable loading of the facets on their own hypothesized factors and very good estimations of Cronbach's alphas for the hypothesized factors, so it was partially supportive of the five-factor structure of the NEO-PI-3.The factors extracted with Procrustes rotation analysis can be considered reasonably homologous to the factors of the American normative sample. Correlations between dimensions were as expected and similar to those reported in the literature. The literature suggests that overall, the psychometric properties of NEO-PI-3 scales have been found to generalize across ages, cultures, and methods of measurement. In accord with this, the results of the current study confirm the reliability of the Greek translation and adaptation of the NEO-PI-3. The inventory has comparable psychometric properties in its Greek version in comparison to the original and other national translations, and it is suitable for clinical as well as research use.
Cheung, Jason Pui Yin; Cheung, Prudence Wing Hang; Wong, Carlos King Ho; Samartzis, Dino; Luk, Keith Dip-Kei; Lam, Cindy Lo Kuen; Cheung, Kenneth Man Chee
2016-12-15
Questionnaire translation and validation. The aim of this study was to translate and cross-culturally adapt the Early Onset Scoliosis-24 item Questionnaire (EOSQ-24) into traditional Chinese, and to assess its validity, reliability, and sensitivity in Southern-Chinese patients diagnosed with early onset scoliosis (EOS). Relying on radiographs alone for assessing treatment outcomes in EOS patients is inadequate. To properly gauge health-related quality of life, a disease-specific instrument that assesses patient quality of life and the burden of primary caregivers is necessary. The EOSQ-24 was created for this purpose, but it has not been adapted to the Chinese language. The translation and cross-cultural adaptation of the original English EOSQ-24 were performed using the method of double forward and single backward translations, followed by a panel review. EOS patients of Southern-Chinese descent were recruited, via convenience sampling from a scoliosis specialty clinic. These patients' parents/caretakers were then administered the traditional Chinese EOSQ-24, Likert Scale regarding the understanding of completed EOSQ-24, and the Child Health Questionnaire Parent Form 50 (CHQ-PF50) (Traditional Chinese). Reliability was analyzed using Cronbach alpha. Construct validity of domains and subdomains was assessed using Spearman correlation test against CHQ-PF50 domains with similar constructs. Sensitivity of the EOSQ-24 scores was determined by performing known group comparisons. A total of 100 EOS patients were recruited. A very good reliability was demonstrated (Cronbach α: 0.896) and internal consistency of all domains was excellent (Cronbach α: 0.829-0.919). Subdomain scores of EOSQ-24 and CHQ-PF50 had significant correlations (P < 0.001), indicating a good construct validity. This is the first psychometric study to translate and adapt the EOSQ-24 questionnaire for Chinese EOS patients and it has been found to have satisfactory validity, reliability, and sensitivity. It is a useful disease-specific instrument for assessing patients' quality of life and the burden of caregivers. 2.
Goknar, Nilüfer; Oktem, Faruk; Demir, Aysegul D; Vehapoglu, Aysel; Silay, Mesrur S
2016-08-01
To compare the correlation of 2 commonly used and validated voiding questionnaires (ICIQ-CLUTS and Akbal's) according to the physician's clinical impressions. Also, we investigated the reliability of these instruments in children with lower urinary tract symptoms (LUTS). Akbal's questionnaires and ICIQ-CLUTS forms were completed by children between 5 and 18 years old with and without LUTS and by their parents. The data were classified into 3 age groups (5-9, 10-13, 14-18). The reliability of Akbal and ICIQ-CLUTS was investigated by using Cronbach's α (≥0.7 is indicated acceptability). The total scores of the tools were compared with the physician's clinical impression (Kendall's tau b-test). A total of 154 children (LUTS: n = 88, controls: n = 66) were prospectively enrolled into the study. The reliability of both instruments was excellent (Cronbach's alpha scores; Akbal = 0.811, ICIQ-CLUTS children version: 0.728 and ICIQ-CLUTS parental version: 0.746). When we compared by Kendal tau, Akbal was better correlated with physician's clinical impression. In addition, the children version of ICIQ-CLUTS was better correlated than parental version. The results of our study provide that both tools are reliable and objective to grade the LUTS in pediatric population. Although both surveys were significantly correlated with clinical impression, the consistency of Akbal's questionnaire is found superior than that of ICIQ-CLUTS. Copyright © 2016 Elsevier Inc. All rights reserved.
Aktürk, Ümmühan; Erci, Behice; Araz, Murat
2017-12-01
This study was conducted for the purpose of adapting the Functional Assessment of Chronic Illness Therapy-Spiritual Well-Being Scale (FACIT-Sp) for the Turkish context and determining its validity and reliability. In 2016, a convenience sample of 137 cancer patients from Malatya State Hospital completed a structured questionnaire, which provided demographic characteristics, and the FACIT-Sp-12 for patients with cancer. The obtained data were assessed using Cronbach's alpha reliability coefficient (α), Pearson's product-moment correlation coefficient (r), factor analysis, Bartlett's test of sphericity, and the Kaiser-Meyer-Olkin (KMO) measure of sampling adequacy. The result of the KMO test was determined to be 0.827 and that of Bartlett's test 988.692, and both were observed to be significant at a level of p < 0.001. The value of Cronbach's α for the Spiritual Well-Being Scale (SWBS) was determined to be 0.87, and the α values for the SWBS subgroups ranged from 0.78 to 0.93. Our analysis determined that the factors had initial eigenvalues above 1, and that they accounted for 61.61% of the total variance. Our study determined that the Turkish version of the FACIT-Sp has validity and reliability and can be used in Turkish society. We believe that the scale can be used safely in determining convenient care and in planning individual educational programs to enhance patients' spiritual well-being.
Rask, Marie; Oscarsson, Marie; Ludwig, Neil; Swahnberg, Katarina
2017-04-04
Cervical dysplasia is a precancerous condition, which has been shown to create anxiety in women. To be able to investigate these women's health-related quality of life, a disease-specific instrument is required. There does not seem to be a Swedish version of an instrument to screen for this specific disease. Therefore, this study aims to translate and cross-culturally adapt the Functional Assessment of Chronic Illness Therapy - Cervical Dysplasia (FACIT-CD) into a Swedish context and evaluate its linguistic validity and reliability. The Functional Assessment of Chronic Illness Therapy (FACIT) translation methodology was used, which consists of several steps including pilot testing of the FACIT-CD instrument through cognitive debriefing interviews. Ten women diagnosed with cervical dysplasia participated in the cognitive debriefing interviews. The internal consistency reliability of the Swedish FACIT-CD was estimated by Cronbach's alpha coefficient. Homogeneity of the items was evaluated by corrected item-total correlations. The sample consists of 34 women who were diagnosed with cervical dysplasia. The translation and cross-cultural adaptation went smoothly without any problems for the majority of the items. The cognitive debriefing interviews indicated that the Swedish FACIT-CD consists of relevant items, is easy to understand and complete, and has unambiguous and comprehensive response categories. The translation and cross-cultural adaptation resulted in a Swedish FACIT-CD, which is conceptually and semantically equivalent to the English version and linguistically valid. The total scale of the Swedish FACIT-CD exhibited good internal consistency reliability with a Cronbach's alpha coefficient of 0.84, and all of the subscales exhibited acceptable value between 0.71 and 0.81 except the Relationships subscale, which had a value of 0.67. Finally, all but four items exceeded the acceptable level for the corrected item-total correlations of ≥ 0.20. The Swedish FACIT-CD is conceptually and semantically equivalent to the English version and linguistically valid; further, it exhibits good internal consistency reliability.
The psychometric properties of the Tinnitus Handicap Questionnaire in a Dutch-speaking population.
Vanneste, S; To, W T; De Ridder, D
2011-02-01
The aim of the study is to translate and validate the tinnitus handicap questionnaire (THQ) for a Dutch-speaking population. The factor structure of the questionnaire, the reliability and the validity is determined. Furthermore, a statistical comparison with the original English version of the tinnitus handicap questionnaire is performed. We assessed 101 patients at the Tinnitus Research Initiative clinic of Antwerp University Hospital. Twenty-seven Dutch items from the tinnitus handicap questionnaire by Kuk et al. [(1990), Ear Hear11:434-45.] were obtained by the process of translation and back translation. The factor structure, internal consistency, was evaluated using Cronbach's alpha coefficient and item correlations were used to confirm reliability. The construct validity was confirmed with a visual analogue scale for loudness and distress, awareness, annoyance, the Tinnitus Questionnaire (TQ), the mini-Tinnitus Questionnaire, the Hospital Anxiety and Depression Scale (HADS), the Beck Depression Inventory (BDI) and the Profile of Mood State (POMS), ensuring that this new instrument measures the tinnitus handicap. This study demonstrates that the Dutch version of the tinnitus handicap questionnaire is a reliable (Cronbach's alpha coefficient α = 0.93) and valid measure of self-perceived tinnitus-related distress [with visual analogue scale for loudness (r = 0.39) and distress (r =0.45), awareness (r = 0.39), annoyance (r = 0.57), the Tinnitus Questionnaire (r = 0.82), the mini-Tinnitus Questionnaire (r = 0.79), the Hospital Anxiety and Depression Scale (r = 0.62) and the Beck Depression Inventory (r = 0.32)]. The psychometric properties are in line with previous findings on the English version with regard to reliability and validity. However, the items in the subscales differ from the English version. While the English version has three subscales, our version has only two subscales. Yet, the English version reports that for the three factors, there is a low internal consistency and low correlation among the different items. For the Dutch-speaking version, both factors show a very high reliability and validity. The tinnitus handicap questionnaire is suitable for assessing the handicapping effects of tinnitus among a Dutch-speaking population in both clinical and research settings. © 2011 Blackwell Publishing Ltd.
Ndagire, Catherine T; Muyonga, John H; Isabirye, Dan; Odur, Benard; Somda, Serge M A; Bukenya, Richard; Andrade, Juan E; Nakimbugwe, Dorothy
2018-06-04
Accurate measurement of body composition in children and adolescents is important as the quantities of fat and fat-free mass have implications for health risk. The objectives of the present study were: to determine the reliability of Fourier Transform Infrared spectroscopy (FTIR) measurements and; compare the Fat Mass (FM), Fat Free Mass (FFM) and body fat percentage (%BF) values determined by bioelectrical impedance analysis (BIA) to those determined by deuterium dilution method (DDM) to identify correlations and agreement between the two methods. A cross-sectional study was conducted among 203 children and adolescents aged 8-19 years attending schools in Kampala city, Uganda. Pearson product-moment correlation at 5% significance level was considered for assessing correlations. Bland Altman analysis was used to examine the agreement between of FTIR measurements and between estimates by DDM and BIA.. Reliability of measurements was determined by Cronbach's alpha. There was good agreement between the in vivo D 2 O saliva enrichment measurements at 3 and 4 h among the studied age groups based on Bland-Altman plots. Cronbach's alpha revealed that measurements of D 2 O saliva enrichment had very good reliability. For children and young adolescents, DDM and BIA gave similar estimates of FFM, FM, and %BF. Among older adolescents, BIA significantly over-estimated FFM and significantly under-estimated FM and %BF compared to estimates by DDM. The correlation between FFM, FM and %BF estimates by DDM and BIA was high and significant among young and older adolescents and for FFM among children. Reliability of the FTIR spectroscopy measurements was very good among the studied population. BIA is suitable for assessing body composition among children (8-9 years) and young adolescents (10-14 years) but not among older adolescents (15-19 years) in Uganda. The body composition measurements of older adolescents determined by DDM can be predicted using those provided by BIA using population-specific regression equations.
Development and validation of the Japanese version of cognitive flexibility scale.
Oshiro, Keiko; Nagaoka, Sawako; Shimizu, Eiji
2016-05-17
Various instruments have been developed to assess cognitive flexibility, which is an important construct in psychology. Among these, the self-report cognitive flexibility scale (CFS) is particularly popular for use with English speakers; however, there is not yet a Japanese version of this scale. This study reports on the development of a Japanese version of the cognitive flexibility scale (CFS-J), and the assessment of its internal consistency, test-retest reliability, and validities. We used the standard translation-back-translation process to develop the Japanese wording of the items and tested these using a sample of 335 eligible participants who did not have a mental illness, were aged 18 years or older, and lived in the suburbs of Tokyo. Participants included office workers, public servants, and college students; 71.6 % were women and 64.8 % were students. The translated scale's internal consistency reliability was assessed by calculating Cronbach's alpha and McDonald's omega, and test-retest reliability was assessed with 107 eligible participants via intra-class correlation coefficient (ICC) and Spearman's correlation of coefficient. Exploratory factory analysis (EFA) and correlations with other scales were used to examine the factor-based and concurrent validities of the CFS-J. Results indicated that the CFS-J has good internal consistency (Cronbach's alpha = 0.847, McDonald's omega = 0.871) and acceptable test-retest reliability (Spearman's = 0.687, ICC = 0.689). EFA provided evidence that the CFS-J has a one-factor structure and factor loadings were generally appropriate. The total CFS-J score was significantly and positively correlated with the cognitive flexibility inventory-Japanese version and its two subscales, along with the cognitive control scale and the positive subscale of the short Japanese version of the automatic thought questionnaire-revised (ATQ-R); further, it had a significantly negative correlation with the negative subscale of the ATQ-R (ps < 0.001). This study developed a Japanese version of the cognitive flexibility scale and confirmed its reliability and validity among a sample of people with no current mental illness, who were living in the suburbs of Tokyo.
The Dental Neglect Scale in adolescents.
Coolidge, Trilby; Heima, Masahiro; Johnson, Elissa K; Weinstein, Philip
2009-01-05
Dental neglect has been found to be related to poor oral health, a tendency not to have had routine check-ups, and a longer period of time since the last dental appointment in samples of children and adults. The Dental Neglect Scale (DNS) has been found to be a valid measure of dental neglect in samples of children and adults, and may be valid for adolescents as well. We administered the DNS to a sample of adolescents and report on the relationships between the DNS and oral health status, whether or not the adolescent has been to the dentist recently for routine check-ups, and whether or not the adolescent currently goes to a dentist. We also report the internal and test-retest reliabilities of the DNS in this sample, as well as the results of an exploratory factor analysis. One hundred seventeen adolescents from seven youth groups in the Seattle-Tacoma metropolitan area (Washington State, U.S.) completed the DNS and indicated whether they currently go to a dentist, while parents indicated whether the adolescent had a check-up in the previous three years. Adolescents also received a dental screening. Sixty six adolescents completed the questionnaire twice. T-tests were used to compare DNS scores of adolescents who have visible caries or not, adolescents who have had a check-up in the past three years or not, and adolescents who currently go to a dentist or not. Internal reliability was measured by Cronbach's alpha, and test-rest reliability was measured by intra-class correlation. Factor analysis (Varimax rotation) was used to examine the factor structure. In each comparison, significantly higher DNS scores were observed in adolescents with visible caries, who have not had a check-up in the past three years, or who do not go to a dentist (all p values < 0.05). The test-retest reliability of the DNS was high (ICC = 0.81), and its internal reliability was acceptable (Cronbach's alpha = 0.60). Factor analysis yielded two factors, characterized by home care and visiting a dentist. The DNS appears to operate similarly in this sample of adolescents as it has in other samples of children and adults.
Tsuji, Naoko; Kakee, Naoko; Ishida, Yasushi; Asami, Keiko; Tabuchi, Ken; Nakadate, Hisaya; Iwai, Tsuyako; Maeda, Miho; Okamura, Jun; Kazama, Takuro; Terao, Yoko; Ohyama, Wataru; Yuza, Yuki; Kaneko, Takashi; Manabe, Atsushi; Kobayashi, Kyoko; Kamibeppu, Kiyoko; Matsushima, Eisuke
2011-04-10
The PedsQL 3.0 Cancer Module is a widely used instrument to measure pediatric cancer specific health-related quality of life (HRQOL) for children aged 2 to 18 years. We developed the Japanese version of the PedsQL Cancer Module and investigated its reliability and validity among Japanese children and their parents. Participants were 212 children with cancer and 253 of their parents. Reliability was determined by internal consistency using Cronbach's coefficient alpha and test-retest reliability using intra-class correlation coefficient (ICC). Validity was assessed through factor validity, convergent and discriminant validity, concurrent validity, and clinical validity. Factor validity was examined by exploratory factor analysis. Convergent and discriminant validity were examined by multitrait scaling analysis. Concurrent validity was assessed using Spearman's correlation coefficients between the Cancer Module and Generic Core Scales, and the comparison of the scores of child self-reports with those of other self-rating depression scales for children. Clinical validity was assessed by comparing the on- and off- treatment scores using Kruskal-Wallis and Mann-Whitney U tests. Cronbach's coefficient alpha was over 0.70 for the total scale and over 0.60 for each subscale by age except for the 'pain and hurt' subscale for children aged 5 to 7 years. For test-retest reliability, the ICC exceeded 0.70 for the total scale for each age. Exploratory factor analysis demonstrated sufficient factorial validity. Multitrait scaling analysis showed high success rates. Strong correlations were found between the reports by children and their parents, and the scores of the Cancer Module and the Generic Core Scales except for 'treatment anxiety' subscales for child reports. The Depression Self-Rating Scale for Children (DSRS-C) scores were significantly correlated with emotional domains and the total score of the cancer module. Children who had been off treatment over 12 months demonstrated significantly higher scores than those on treatment. The results demonstrate the reliability and validity of the Japanese version of the PedsQL Cancer Module among Japanese children.
Paddock, L E; Veloski, J; Chatterton, M L; Gevirtz, F O; Nash, D B
2000-07-01
To develop a reliable and valid questionnaire to measure patient satisfaction with diabetes disease management programs. Questions related to structure, process, and outcomes were categorized into 14 domains defining the essential elements of diabetes disease management. Health professionals confirmed the content validity. Face validity was established by a patient focus group. The questionnaire was mailed to 711 patients with diabetes who participated in a disease management program. To reduce the number of questionnaire items, a principal components analysis was performed using a varimax rotation. The Scree test was used to select significant components. To further assess reliability and validity; Cronbach's alpha and product-moment correlations were calculated for components having > or =3 items with loadings >0.50. The validated 73-item mailed satisfaction survey had a 34.1% response rate. Principal components analysis yielded 13 components with eigenvalues > 1.0. The Scree test proposed a 6-component solution (39 items), which explained 59% of the total variation. Internal consistency reliabilities computed for the first 6 components (alpha = 0.79-0.95) were acceptable. The final questionnaire, the Diabetes Management Evaluation Tool (DMET), was designed to assess patient satisfaction with diabetes disease management programs. Although more extensive testing of the questionnaire is appropriate, preliminary reliability and validity of the DMET has been demonstrated.
Reliability of the detailed assessment of speed of handwriting on Flemish children.
Simons, Johan; Probst, Michel
2014-01-01
This study evaluates the reliability of the Detailed Assessment of Speed of Handwriting (DASH) in a Dutch-speaking sample of children. The sample included 650 boys and 513 girls (age range = 9-16 years). Handwriting speed measurements were obtained using the DASH. Interrater agreement, test-retest reliability, and internal consistency were calculated; gender and age effects were analyzed. Interrater agreement shows excellent reliability with intraclass correlation coefficients of at least 0.94. Test-retest correlations ranged from r = 0.65 to r = 0.81. The internal consistency measures, calculated with Cronbach's alpha, were between 0.88 and 0.94. Both gender and age have a significant effect on handwriting speed, with F (7.1144) = 17.43 (P < .001) for gender and F (7.1144) = 21.8 (P < .001) for age. The DASH is a reliable assessment tool to evaluate handwriting speed of Dutch-speaking children. There is a tendency of girls to write faster than boys.
[The reliability of a questionnaire regarding Colombian children's physical activity].
Herazo-Beltrán, Aliz Y; Domínguez-Anaya, Regina
2012-10-01
Reporting the Physical Activity Questionnaire for school children's (PAQ-C) test-retest reliability and internal consistency. This was a descriptive study of 100 school-aged children aged 9 to 11 years old attending a school in Cartagena, Colombia. The sample was randomly selected. The PAQ-C was given twice, one week apart, after the informed consent forms had been signing by the children's parents and school officials. Cronbach's alpha coefficient of reliability was used for assessing internal consistency and an intra-class correlation coefficient for test-retest reliability SPSS (version 17.0) was used for statistical analysis. The questionnaire scored 0.73 internal consistencies during the first measurement and 0.78 on the second; intra-class correlation coefficient was 0.60. There were differences between boys and girls regarding both measurements. The PAQ-C had acceptable internal consistency and test-retest reliability, thereby making it useful for measuring children's self-reported physical activity and a valuable tool for population studies in Colombia.
Sharif Nia, Hamid; Pahlevan Sharif, Saeed; Koocher, Gerald P; Yaghoobzadeh, Ameneh; Haghdoost, Ali Akbar; Mar Win, Ma Thin; Soleimani, Mohammad Ali
2017-01-01
This study aimed to evaluate the validity and reliability of the Persian version of Death Anxiety Scale-Extended (DAS-E). A total of 507 patients with end-stage renal disease completed the DAS-E. The factor structure of the scale was evaluated using exploratory factor analysis with an oblique rotation and confirmatory factor analysis. The content and construct validity of the DAS-E were assessed. Average variance extracted, maximum shared squared variance, and average shared squared variance were estimated to assess discriminant and convergent validity. Reliability was assessed using Cronbach's alpha coefficient (α = .839 and .831), composite reliability (CR = .845 and .832), Theta (θ = .893 and .867), and McDonald Omega (Ω = .796 and .743). The analysis indicated a two-factor solution. Reliability and discriminant validity of the factors was established. Findings revealed that the present scale was a valid and reliable instrument that can be used in assessment of death anxiety in Iranian patients with end-stage renal disease.
Vieira, Maria Aparecida; Ohara, Conceição Vieira da Silva; de Domenico, Edvane Birelo Lopes
2016-01-01
Abstract Objective: to construct an instrument for the assessment of graduates of undergraduate nursing courses and to validate this instrument through the consensus of specialists. Method: methodological study. In order to elaborate the instrument, documental analysis and a literature review were undertaken. Validation took place through use of the Delphi Conference, between September 2012 and September 2013, in which 36 specialists from Brazilian Nursing participated. In order to analyze reliability, the Cronbach alpha coefficient, the item/total correlation, and the Pearson correlation coefficient were calculated. Results: the instrument was constructed with the participation of specialist nurses representing all regions of Brazil, with experience in lecturing and research. The first Delphi round led to changes in the first instrument, which was restructured and submitted to another round, with a response rate of 94.44%. In the second round, the instrument was validated with a Cronbach alpha of 0.75. Conclusion: the final instrument possessed three dimensions related to the characterization of the graduate, insertion in the job market, and evaluation of the professional training process. This instrument may be used across the territory of Brazil as it is based on the curricular guidelines and contributes to the process of regulation of the quality of the undergraduate courses in Nursing. PMID:27305184