Error estimates for ice discharge calculated using the flux gate approach
NASA Astrophysics Data System (ADS)
Navarro, F. J.; Sánchez Gámez, P.
2017-12-01
Ice discharge to the ocean is usually estimated using the flux gate approach, in which ice flux is calculated through predefined flux gates close to the marine glacier front. However, published results usually lack a proper error estimate. In the flux calculation, both errors in cross-sectional area and errors in velocity are relevant. While for estimating the errors in velocity there are well-established procedures, the calculation of the error in the cross-sectional area requires the availability of ground penetrating radar (GPR) profiles transverse to the ice-flow direction. In this contribution, we use IceBridge operation GPR profiles collected in Ellesmere and Devon Islands, Nunavut, Canada, to compare the cross-sectional areas estimated using various approaches with the cross-sections estimated from GPR ice-thickness data. These error estimates are combined with those for ice-velocities calculated from Sentinel-1 SAR data, to get the error in ice discharge. Our preliminary results suggest, regarding area, that the parabolic cross-section approaches perform better than the quartic ones, which tend to overestimate the cross-sectional area for flight lines close to the central flowline. Furthermore, the results show that regional ice-discharge estimates made using parabolic approaches provide reasonable results, but estimates for individual glaciers can have large errors, up to 20% in cross-sectional area.
Cross Section Sensitivity and Propagated Errors in HZE Exposures
NASA Technical Reports Server (NTRS)
Heinbockel, John H.; Wilson, John W.; Blatnig, Steve R.; Qualls, Garry D.; Badavi, Francis F.; Cucinotta, Francis A.
2005-01-01
It has long been recognized that galactic cosmic rays are of such high energy that they tend to pass through available shielding materials resulting in exposure of astronauts and equipment within space vehicles and habitats. Any protection provided by shielding materials result not so much from stopping such particles but by changing their physical character in interaction with shielding material nuclei forming, hopefully, less dangerous species. Clearly, the fidelity of the nuclear cross-sections is essential to correct specification of shield design and sensitivity to cross-section error is important in guiding experimental validation of cross-section models and database. We examine the Boltzmann transport equation which is used to calculate dose equivalent during solar minimum, with units (cSv/yr), associated with various depths of shielding materials. The dose equivalent is a weighted sum of contributions from neutrons, protons, light ions, medium ions and heavy ions. We investigate the sensitivity of dose equivalent calculations due to errors in nuclear fragmentation cross-sections. We do this error analysis for all possible projectile-fragment combinations (14,365 such combinations) to estimate the sensitivity of the shielding calculations to errors in the nuclear fragmentation cross-sections. Numerical differentiation with respect to the cross-sections will be evaluated in a broad class of materials including polyethylene, aluminum and copper. We will identify the most important cross-sections for further experimental study and evaluate their impact on propagated errors in shielding estimates.
Cross sections for H(-) and Cl(-) production from HCl by dissociative electron attachment
NASA Technical Reports Server (NTRS)
Orient, O. J.; Srivastava, S. K.
1985-01-01
A crossed target beam-electron beam collision geometry and a quadrupole mass spectrometer have been used to conduct dissociative electron attachment cross section measurements for the case of H(-) and Cl(-) production from HCl. The relative flow technique is used to determine the absolute values of cross sections. A tabulation is given of the attachment energies corresponding to various cross section maxima. Error sources contributing to total errors are also estimated.
Total absorption cross sections of several gases of aeronomic interest at 584 A.
NASA Technical Reports Server (NTRS)
Starr, W. L.; Loewenstein, M.
1972-01-01
Total photoabsorption cross sections have been measured at 584.3 A for N2, O2, Ar, CO2, CO, NO, N2O, NH3, CH4, H2, and H2S. A monochromator was used to isolate the He I 584 line produced in a helium resonance lamp, and thin aluminum filters were used as absorption cell windows, thereby eliminating possible errors associated with the use of undispersed radiation or windowless cells. Sources of error are examined, and limits of uncertainty are given. Previous relevant cross-sectional measurements and possible error sources are reviewed. Wall adsorption as a source of error in cross-sectional measurements has not previously been considered and is discussed briefly.
Sensitivity Analysis of Nuclide Importance to One-Group Neutron Cross Sections
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sekimoto, Hiroshi; Nemoto, Atsushi; Yoshimura, Yoshikane
The importance of nuclides is useful when investigating nuclide characteristics in a given neutron spectrum. However, it is derived using one-group microscopic cross sections, which may contain large errors or uncertainties. The sensitivity coefficient shows the effect of these errors or uncertainties on the importance.The equations for calculating sensitivity coefficients of importance to one-group nuclear constants are derived using the perturbation method. Numerical values are also evaluated for some important cases for fast and thermal reactor systems.Many characteristics of the sensitivity coefficients are derived from the derived equations and numerical results. The matrix of sensitivity coefficients seems diagonally dominant. However,more » it is not always satisfied in a detailed structure. The detailed structure of the matrix and the characteristics of coefficients are given.By using the obtained sensitivity coefficients, some demonstration calculations have been performed. The effects of error and uncertainty of nuclear data and of the change of one-group cross-section input caused by fuel design changes through the neutron spectrum are investigated. These calculations show that the sensitivity coefficient is useful when evaluating error or uncertainty of nuclide importance caused by the cross-section data error or uncertainty and when checking effectiveness of fuel cell or core design change for improving neutron economy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adare, A.; Aidala, C.; Ajitanand, N. N.
2015-02-02
We present midrapidity charged-pion invariant cross sections, the ratio of the π⁻ to π⁺ cross sections and the charge-separated double-spin asymmetries in polarized p+p collisions at √s = 200 GeV. While the cross section measurements are consistent within the errors of next-to-leadingorder (NLO) perturbative quantum chromodynamics predictions (pQCD), the same calculations over estimate the ratio of the charged-pion cross sections. This discrepancy arises from the cancellation of the substantial systematic errors associated with the NLO-pQCD predictions in the ratio and highlights the constraints these data will place on flavor dependent pion fragmentation functions. Thus, the charge-separated pion asymmetries presented heremore » sample an x range of ~0.03–0.16 and provide unique information on the sign of the gluon-helicity distribution.« less
NASA Astrophysics Data System (ADS)
Adare, A.; Aidala, C.; Ajitanand, N. N.; Akiba, Y.; Akimoto, R.; Al-Ta'Ani, H.; Alexander, J.; Andrews, K. R.; Angerami, A.; Aoki, K.; Apadula, N.; Appelt, E.; Aramaki, Y.; Armendariz, R.; Aschenauer, E. C.; Atomssa, E. T.; Awes, T. C.; Azmoun, B.; Babintsev, V.; Bai, M.; Bannier, B.; Barish, K. N.; Bassalleck, B.; Basye, A. T.; Bathe, S.; Baublis, V.; Baumann, C.; Bazilevsky, A.; Belmont, R.; Ben-Benjamin, J.; Bennett, R.; Blau, D. S.; Bok, J. S.; Boyle, K.; Brooks, M. L.; Broxmeyer, D.; Buesching, H.; Bumazhnov, V.; Bunce, G.; Butsyk, S.; Campbell, S.; Castera, P.; Chen, C.-H.; Chi, C. Y.; Chiu, M.; Choi, I. J.; Choi, J. B.; Choudhury, R. K.; Christiansen, P.; Chujo, T.; Chvala, O.; Cianciolo, V.; Citron, Z.; Cole, B. A.; Conesa Del Valle, Z.; Connors, M.; Csanád, M.; Csörgő, T.; Dairaku, S.; Datta, A.; David, G.; Dayananda, M. K.; Denisov, A.; Deshpande, A.; Desmond, E. J.; Dharmawardane, K. V.; Dietzsch, O.; Dion, A.; Donadelli, M.; Drapier, O.; Drees, A.; Drees, K. A.; Durham, J. M.; Durum, A.; D'Orazio, L.; Efremenko, Y. V.; Engelmore, T.; Enokizono, A.; En'yo, H.; Esumi, S.; Fadem, B.; Fields, D. E.; Finger, M.; Finger, M.; Fleuret, F.; Fokin, S. L.; Frantz, J. E.; Franz, A.; Frawley, A. D.; Fukao, Y.; Fusayasu, T.; Gal, C.; Garishvili, I.; Giordano, F.; Glenn, A.; Gong, X.; Gonin, M.; Goto, Y.; Granier de Cassagnac, R.; Grau, N.; Greene, S. V.; Grosse Perdekamp, M.; Gunji, T.; Guo, L.; Gustafsson, H.-Å.; Haggerty, J. S.; Hahn, K. I.; Hamagaki, H.; Hamblen, J.; Han, R.; Hanks, J.; Harper, C.; Hashimoto, K.; Haslum, E.; Hayano, R.; He, X.; Hemmick, T. K.; Hester, T.; Hill, J. C.; Hollis, R. S.; Holzmann, W.; Homma, K.; Hong, B.; Horaguchi, T.; Hori, Y.; Hornback, D.; Huang, S.; Ichihara, T.; Ichimiya, R.; Iinuma, H.; Ikeda, Y.; Imai, K.; Inaba, M.; Iordanova, A.; Isenhower, D.; Ishihara, M.; Issah, M.; Ivanischev, D.; Iwanaga, Y.; Jacak, B. V.; Jia, J.; Jiang, X.; John, D.; Johnson, B. M.; Jones, T.; Joo, K. S.; Jouan, D.; Kamin, J.; Kaneti, S.; Kang, B. H.; Kang, J. H.; Kang, J. S.; Kapustinsky, J.; Karatsu, K.; Kasai, M.; Kawall, D.; Kazantsev, A. V.; Kempel, T.; Khanzadeev, A.; Kijima, K. M.; Kim, B. I.; Kim, D. J.; Kim, E.-J.; Kim, Y.-J.; Kim, Y. K.; Kinney, E.; Kiss, Á.; Kistenev, E.; Kleinjan, D.; Kline, P.; Kochenda, L.; Komkov, B.; Konno, M.; Koster, J.; Kotov, D.; Král, A.; Kunde, G. J.; Kurita, K.; Kurosawa, M.; Kwon, Y.; Kyle, G. S.; Lacey, R.; Lai, Y. S.; Lajoie, J. G.; Lebedev, A.; Lee, D. M.; Lee, J.; Lee, K. B.; Lee, K. S.; Lee, S. H.; Lee, S. R.; Leitch, M. J.; Leite, M. A. L.; Li, X.; Lim, S. H.; Linden Levy, L. A.; Liu, H.; Liu, M. X.; Love, B.; Lynch, D.; Maguire, C. F.; Makdisi, Y. I.; Manion, A.; Manko, V. I.; Mannel, E.; Mao, Y.; Masui, H.; McCumber, M.; McGaughey, P. L.; McGlinchey, D.; McKinney, C.; Means, N.; Mendoza, M.; Meredith, B.; Miake, Y.; Mibe, T.; Mignerey, A. C.; Miki, K.; Milov, A.; Mitchell, J. T.; Miyachi, Y.; Mohanty, A. K.; Moon, H. J.; Morino, Y.; Morreale, A.; Morrison, D. P.; Motschwiller, S.; Moukhanova, T. V.; Murakami, T.; Murata, J.; Nagamiya, S.; Nagle, J. L.; Naglis, M.; Nagy, M. I.; Nakagawa, I.; Nakamiya, Y.; Nakamura, K. R.; Nakamura, T.; Nakano, K.; Newby, J.; Nguyen, M.; Nihashi, M.; Nouicer, R.; Nyanin, A. S.; Oakley, C.; O'Brien, E.; Ogilvie, C. A.; Oka, M.; Okada, K.; Oskarsson, A.; Ouchida, M.; Ozawa, K.; Pak, R.; Pantuev, V.; Papavassiliou, V.; Park, B. H.; Park, I. H.; Park, S. K.; Pate, S. F.; Patel, L.; Pei, H.; Peng, J.-C.; Pereira, H.; Peressounko, D. Yu.; Petti, R.; Pinkenburg, C.; Pisani, R. P.; Proissl, M.; Purschke, M. L.; Qu, H.; Rak, J.; Ravinovich, I.; Read, K. F.; Reygers, K.; Riabov, V.; Riabov, Y.; Richardson, E.; Roach, D.; Roche, G.; Rolnick, S. D.; Rosati, M.; Rosendahl, S. S. E.; Rubin, J. G.; Sahlmueller, B.; Saito, N.; Sakaguchi, T.; Samsonov, V.; Sano, S.; Sarsour, M.; Sato, T.; Savastio, M.; Sawada, S.; Sedgwick, K.; Seidl, R.; Seto, R.; Sharma, D.; Shein, I.; Shibata, T.-A.; Shigaki, K.; Shim, H. H.; Shimomura, M.; Shoji, K.; Shukla, P.; Sickles, A.; Silva, C. L.; Silvermyr, D.; Silvestre, C.; Sim, K. S.; Singh, B. K.; Singh, C. P.; Singh, V.; Slunečka, M.; Sodre, T.; Soltz, R. A.; Sondheim, W. E.; Sorensen, S. P.; Sourikova, I. V.; Stankus, P. W.; Stenlund, E.; Stoll, S. P.; Sugitate, T.; Sukhanov, A.; Sun, J.; Sziklai, J.; Takagui, E. M.; Takahara, A.; Taketani, A.; Tanabe, R.; Tanaka, Y.; Taneja, S.; Tanida, K.; Tannenbaum, M. J.; Tarafdar, S.; Taranenko, A.; Tennant, E.; Themann, H.; Thomas, D.; Togawa, M.; Tomášek, L.; Tomášek, M.; Torii, H.; Towell, R. S.; Tserruya, I.; Tsuchimoto, Y.; Utsunomiya, K.; Vale, C.; van Hecke, H. W.; Vazquez-Zambrano, E.; Veicht, A.; Velkovska, J.; Vértesi, R.; Virius, M.; Vossen, A.; Vrba, V.; Vznuzdaev, E.; Wang, X. R.; Watanabe, D.; Watanabe, K.; Watanabe, Y.; Watanabe, Y. S.; Wei, F.; Wei, R.; Wessels, J.; White, S. N.; Winter, D.; Woody, C. L.; Wright, R. M.; Wysocki, M.; Yamaguchi, Y. L.; Yang, R.; Yanovich, A.; Ying, J.; Yokkaichi, S.; Yoo, J. S.; You, Z.; Young, G. R.; Younus, I.; Yushmanov, I. E.; Zajc, W. A.; Zelenski, A.; Zhou, S.; Phenix Collaboration
2015-02-01
We present midrapidity charged-pion invariant cross sections, the ratio of the π- to π+ cross sections and the charge-separated double-spin asymmetries in polarized p +p collisions at √{s }=200 GeV . While the cross section measurements are consistent within the errors of next-to-leading-order (NLO) perturbative quantum chromodynamics predictions (pQCD), the same calculations overestimate the ratio of the charged-pion cross sections. This discrepancy arises from the cancellation of the substantial systematic errors associated with the NLO-pQCD predictions in the ratio and highlights the constraints these data will place on flavor-dependent pion fragmentation functions. The charge-separated pion asymmetries presented here sample an x range of ˜0.03 - 0.16 and provide unique information on the sign of the gluon-helicity distribution.
Digital floodplain mapping and an analysis of errors involved
Hamblen, C.S.; Soong, D.T.; Cai, X.
2007-01-01
Mapping floodplain boundaries using geographical information system (GIS) and digital elevation models (DEMs) was completed in a recent study. However convenient this method may appear at first, the resulting maps potentially can have unaccounted errors. Mapping the floodplain using GIS is faster than mapping manually, and digital mapping is expected to be more common in the future. When mapping is done manually, the experience and judgment of the engineer or geographer completing the mapping and the contour resolution of the surface topography are critical in determining the flood-plain and floodway boundaries between cross sections. When mapping is done digitally, discrepancies can result from the use of the computing algorithm and digital topographic datasets. Understanding the possible sources of error and how the error accumulates through these processes is necessary for the validation of automated digital mapping. This study will evaluate the procedure of floodplain mapping using GIS and a 3 m by 3 m resolution DEM with a focus on the accumulated errors involved in the process. Within the GIS environment of this mapping method, the procedural steps of most interest, initially, include: (1) the accurate spatial representation of the stream centerline and cross sections, (2) properly using a triangulated irregular network (TIN) model for the flood elevations of the studied cross sections, the interpolated elevations between them and the extrapolated flood elevations beyond the cross sections, and (3) the comparison of the flood elevation TIN with the ground elevation DEM, from which the appropriate inundation boundaries are delineated. The study area involved is of relatively low topographic relief; thereby, making it representative of common suburban development and a prime setting for the need of accurately mapped floodplains. This paper emphasizes the impacts of integrating supplemental digital terrain data between cross sections on floodplain delineation. ?? 2007 ASCE.
A new automated method for the determination of cross-section limits in ephemeral gullies
NASA Astrophysics Data System (ADS)
Castillo, Carlos; Ángel Campo-Bescós, Miguel; Casalí, Javier; Giménez, Rafael
2017-04-01
The assessment of gully erosion relies on the estimation of the soil volume enclosed by cross sections limits. Both 3D and 2D methods require the application of a methodology for the determination of the cross-section limits what has been traditionally carried out in two ways: a) by visual inspection of the cross-section by a certain expert operator; b) by the automated identification of thresholds for different geometrical variables such as elevation, slope or plan curvature obtained from the cross-section profile. However, for these last methods, typically, the thresholds are not of general application because they depend on absolute values valid only for the local gully conditions where they were derived. In this communication we evaluate an automated method for cross-section delimitation of ephemeral gullies and compare its performance with the visual assessment provided by five scientists experienced in gully erosion assessment, defining gully width, depth and area for a total of 60 ephemeral gullies cross-sections obtained from field surveys conducted on agricultural plots in Navarra (Spain). The automated method only depends on the calculation of a simple geometrical measurement, which is the bank trapezoid area for every point of each gully bank. This rectangle trapezoid (right-angled trapezoid) is defined by the elevation of a given point, the minimum elevation and the extremes of the cross-section. The gully limit for each bank is determined by the point in the bank with the maximum trapezoid area. The comparison of the estimates among the different expert operators showed large variation coefficients (up to 70%) in a number of cross-sections, larger for cross sections width and area and smaller for cross sections depth. The automated method produced comparable results to those obtained by the experts and was the procedure with the highest average correlation with the rest of the methods for the three dimensional parameters. The errors of the automated method when compared with the average estimate of the experts were occasionally high (up to 40%), in line with the variability found among experts. The automated method showed no apparent systematic errors which approximately followed a normal distribution, although these errors were slightly biased towards overestimation for the depth and area parameters. In conclusion, this study shows that there is not a single definition of gully limits even among gully experts where a large variability was found. The bank trapezoid method was found to be an automated, easy-to-use (readily implementable in a basic excel spread-sheet or programming scripts), threshold-independent procedure to determine consistently gully limits similar to expert-derived estimates. Gully width and area calculations were more prone to errors than gully depth, which was the least sensitive parameter.
Sloat, J.V.; Gain, W.S.
1995-01-01
Index-velocity data collected with acoustic velocity meters, stage data, and cross-sectional area data were used to calculate discharge at three low-velocity, tidal streamflow stations in north-east Florida. Discharge at three streamflow stations was computed as the product of the channel cross-sectional area and the mean velocity as determined from an index velocity measured in the stream using an acoustic velocity meter. The tidal streamlflow stations used in the study were: Six Mile Creek near Picolata, Fla.; Dunns Creek near Satsuma, Fla.; and the St. Johns River at Buffalo Bluff. Cross-sectional areas at the measurement sections ranged from about 3,000 square feet at Six Mile Creek to about 18,500 square feet at St. Johns River at Buffalo Bluff. Physical characteristics for all three streams were similar except for drainage area. The topography primarily is low-relief, swampy terrain; stream velocities ranged from about -2 to 2 feet per second; and the average change in stage was about 1 foot. Instantaneous discharge was measured using a portable acoustic current meter at each of the three streams to develop a relation between the mean velocity in the stream and the index velocity measured by the acoustic velocity meter. Using least-squares linear regression, a simple linear relation between mean velocity and index velocity was determined. Index velocity was the only significant linear predictor of mean velocity for Six Mile Creek and St. Johns River at Buffalo Bluff. For Dunns Creek, both index velocity and stage were used to develop a multiple-linear predictor of mean velocity. Stage-area curves for each stream were developed from bathymetric data. Instantaneous discharge was computed by multiplying results of relations developed for cross-sectional area and mean velocity. Principal sources of error in the estimated discharge are identified as: (1) instrument errors associated with measurement of stage and index velocity, (2) errors in the representation of mean daily stage and index velocity due to natural variability over time and space, and (3) errors in cross-sectional area and mean-velocity ratings based on stage and index velocity. Standard errors for instantaneous discharge for the median cross-sectional area for Six Mile Creek, Dunns Creek, and St. Johns River at Buffalo Bluff were 94,360, and 1,980 cubic feet per second, respectively. Standard errors for mean daily discharge for the median cross-sectional area for Six Mile Creek, Dunns Creek, and St. Johns River at Buffalo Bluff were 25, 65, and 455 cubic feet per second, respectively. Mean daily discharge at the three sites ranged from about -500 to 1,500 cubic feet per second at Six Mile Creek and Dunns Creek and from about -500 to 15,000 cubic feet per second on the St. Johns River at Buffalo Bluff. For periods of high discharge, the AVM index-velocity method tended to produce estimates accurate with 2 to 6 percent. For periods of moderate discharge, errors in discharge may increase to more than 50 percent. At low flows, errors as a percentage of discharge increase toward infinity.
Reduced backscattering cross section (Sigma degree) data from the Skylab S-193 radar altimeter
NASA Technical Reports Server (NTRS)
Brown, G. S.
1975-01-01
Backscattering cross section per unit scattering area data, reduced from measurements made by the Skylab S-193 radar altimeter over the ocean surface are presented. Descriptions of the altimeter are given where applicable to the measurement process. Analytical solutions are obtained for the flat surface impulse response for the case of a nonsymmetrical antenna pattern. Formulations are developed for converting altimeter AGC outputs into values for the backscattering cross section. Reduced data are presented for Missions SL-2, 3 and 4 for all modes of the altimeter where sufficient calibration existed. The problem of interpreting land scatter data is also discussed. Finally, a comprehensive error analysis of the measurement is presented and worst case random and bias errors are estimated.
Error Orientation and Reflection at Work
ERIC Educational Resources Information Center
Hetzner, Stefanie; Gartmeier, Martin; Heid, Helmut; Gruber, Hans
2011-01-01
Reflection on events at work, including errors is often as a means to learn effectively through work. In a cross-sectional field study in the banking sector, we investigated attitudes towards workplace errors (i.e. error orientation) as predictors of reflective activity. We assumed the organisational climate for psychological safety to have a…
Validation of Metrics as Error Predictors
NASA Astrophysics Data System (ADS)
Mendling, Jan
In this chapter, we test the validity of metrics that were defined in the previous chapter for predicting errors in EPC business process models. In Section 5.1, we provide an overview of how the analysis data is generated. Section 5.2 describes the sample of EPCs from practice that we use for the analysis. Here we discuss a disaggregation by the EPC model group and by error as well as a correlation analysis between metrics and error. Based on this sample, we calculate a logistic regression model for predicting error probability with the metrics as input variables in Section 5.3. In Section 5.4, we then test the regression function for an independent sample of EPC models from textbooks as a cross-validation. Section 5.5 summarizes the findings.
NASA Technical Reports Server (NTRS)
Moore, E. N.; Altick, P. L.
1972-01-01
The research performed is briefly reviewed. A simple method was developed for the calculation of continuum states of atoms when autoionization is present. The method was employed to give the first theoretical cross section for beryllium and magnesium; the results indicate that the values used previously at threshold were sometimes seriously in error. These threshold values have potential applications in astrophysical abundance estimates.
Giblin, Jay; Syed, Muhammad; Banning, Michael T; Kuno, Masaru; Hartland, Greg
2010-01-26
Absorption cross sections ((sigma)abs) of single branched CdSe nanowires (NWs) have been measured by photothermal heterodyne imaging (PHI). Specifically, PHI signals from isolated gold nanoparticles (NPs) with known cross sections were compared to those of individual CdSe NWs excited at 532 nm. This allowed us to determine average NW absorption cross sections at 532 nm of (sigma)abs = (3.17 +/- 0.44) x 10(-11) cm2/microm (standard error reported). This agrees well with a theoretical value obtained using a classical electromagnetic analysis ((sigma)abs = 5.00 x 10(-11) cm2/microm) and also with prior ensemble estimates. Furthermore, NWs exhibit significant absorption polarization sensitivities consistent with prior NW excitation polarization anisotropy measurements. This has enabled additional estimates of the absorption cross section parallel ((sigma)abs) and perpendicular ((sigma)abs(perpendicular) to the NW growth axis, as well as the corresponding NW absorption anisotropy ((rho)abs). Resulting values of (sigma)abs = (5.6 +/- 1.1) x 10(-11) cm2/microm, (sigma)abs(perpendicular) = (1.26 +/- 0.21) x 10(-11) cm2/microm, and (rho)abs = 0.63+/- 0.04 (standard errors reported) are again in good agreement with theoretical predictions. These measurements all indicate sizable NW absorption cross sections and ultimately suggest the possibility of future direct single NW absorption studies.
Proton upsets in LSI memories in space
NASA Technical Reports Server (NTRS)
Mcnulty, P. J.; Wyatt, R. C.; Filz, R. C.; Rothwell, P. L.; Farrell, G. E.
1980-01-01
Two types of large scale integrated dynamic random access memory devices were tested and found to be subject to soft errors when exposed to protons incident at energies between 18 and 130 MeV. These errors are shown to differ significantly from those induced in the same devices by alphas from an Am-241 source. There is considerable variation among devices in their sensitivity to proton-induced soft errors, even among devices of the same type. For protons incident at 130 MeV, the soft error cross sections measured in these experiments varied from 10 to the -8th to 10 to the -6th sq cm/proton. For individual devices, however, the soft error cross section consistently increased with beam energy from 18-130 MeV. Analysis indicates that the soft errors induced by energetic protons result from spallation interactions between the incident protons and the nuclei of the atoms comprising the device. Because energetic protons are the most numerous of both the galactic and solar cosmic rays and form the inner radiation belt, proton-induced soft errors have potentially serious implications for many electronic systems flown in space.
NASA Technical Reports Server (NTRS)
Brown, G. S.; Curry, W. J.
1977-01-01
The statistical error of the pointing angle estimation technique is determined as a function of the effective receiver signal to noise ratio. Other sources of error are addressed and evaluated with inadequate calibration being of major concern. The impact of pointing error on the computation of normalized surface scattering cross section (sigma) from radar and the waveform attitude induced altitude bias is considered and quantitative results are presented. Pointing angle and sigma processing algorithms are presented along with some initial data. The intensive mode clean vs. clutter AGC calibration problem is analytically resolved. The use clutter AGC data in the intensive mode is confirmed as the correct calibration set for the sigma computations.
NASA Technical Reports Server (NTRS)
Brucker, G. J.; Stassinopoulos, E. G.
1991-01-01
An analysis of the expected space radiation effects on the single event upset (SEU) properties of CMOS/bulk memories onboard the Combined Release and Radiation Effects Satellite (CRRES) is presented. Dose-imprint data from ground test irradiations of identical devices are applied to the predictions of cosmic-ray-induced space upset rates in the memories onboard the spacecraft. The calculations take into account the effect of total dose on the SEU sensitivity of the devices as the dose accumulates in orbit. Estimates of error rates, which involved an arbitrary selection of a single pair of threshold linear energy transfer (LET) and asymptotic cross-section values, were compared to the results of an integration over the cross-section curves versus LET. The integration gave lower upset rates than the use of the selected values of the SEU parameters. Since the integration approach is more accurate and eliminates the need for an arbitrary definition of threshold LET and asymptotic cross section, it is recommended for all error rate predictions where experimental sigma-versus-LET curves are available.
Improved Neutronics Treatment of Burnable Poisons for the Prismatic HTR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Y. Wang; A. A. Bingham; J. Ortensi
2012-10-01
In prismatic block High Temperature Reactors (HTR), highly absorbing material such a burnable poison (BP) cause local flux depressions and large gradients in the flux across the blocks which can be a challenge to capture accurately with traditional homogenization methods. The purpose of this paper is to quantify the error associated with spatial homogenization, spectral condensation and discretization and to highlight what is needed for improved neutronics treatments of burnable poisons for the prismatic HTR. A new triangular based mesh is designed to separate the BP regions from the fuel assembly. A set of packages including Serpent (Monte Carlo), Xuthosmore » (1storder Sn), Pronghorn (diffusion), INSTANT (Pn) and RattleSnake (2ndorder Sn) is used for this study. The results from the deterministic calculations show that the cross sections generated directly in Serpent are not sufficient to accurately reproduce the reference Monte Carlo solution in all cases. The BP treatment produces good results, but this is mainly due to error cancellation. However, the Super Cell (SC) approach yields cross sections that are consistent with cross sections prepared on an “exact” full core calculation. In addition, very good agreement exists between the various deterministic transport and diffusion codes in both eigenvalue and power distributions. Future research will focus on improving the cross sections and quantifying the error cancellation.« less
NASA Astrophysics Data System (ADS)
Chen, R. M.; Diggins, Z. J.; Mahatme, N. N.; Wang, L.; Zhang, E. X.; Chen, Y. P.; Zhang, H.; Liu, Y. N.; Narasimham, B.; Witulski, A. F.; Bhuva, B. L.; Fleetwood, D. M.
2017-08-01
The single-event sensitivity of bulk 40-nm sequential circuits is investigated as a function of temperature and supply voltage. An overall increase in SEU cross section versus temperature is observed at relatively high supply voltages. However, at low supply voltages, there is a threshold temperature beyond which the SEU cross section decreases with further increases in temperature. Single-event transient induced errors in flip-flops also increase versus temperature at relatively high supply voltages and are more sensitive to temperature variation than those caused by single-event upsets.
Photon scattering cross sections of H2 and He measured with synchrotron radiation
NASA Technical Reports Server (NTRS)
Ice, G. E.
1977-01-01
Total (elastic + inelastic) differential photon scattering cross sections have been measured for H2 gas and He, using an X-ray beam. Absolute measured cross sections agree with theory within the probable errors. Relative cross sections (normalized to theory at large S) agree to better than one percent with theoretical values calculated from wave functions that include the effect of electron-electron Coulomb correlation, but the data deviate significantly from theoretical independent-particle (e.g., Hartree-Fock) results. The ratios of measured absolute He cross sections to those of H2, at any given S, also agree to better than one percent with theoretical He-to-H2 cross-section ratios computed from correlated wave functions. It appears that photon scattering constitutes a very promising tool for probing electron correlation in light atoms and molecules.
Deuterium target data for precision neutrino-nucleus cross sections
Meyer, Aaron S.; Betancourt, Minerba; Gran, Richard; ...
2016-06-23
Amplitudes derived from scattering data on elementary targets are basic inputs to neutrino-nucleus cross section predictions. A prominent example is the isovector axial nucleon form factor, F A(q 2), which controls charged current signal processes at accelerator-based neutrino oscillation experiments. Previous extractions of F A from neutrino-deuteron scattering data rely on a dipole shape assumption that introduces an unquantified error. A new analysis of world data for neutrino-deuteron scattering is performed using a model-independent, and systematically improvable, representation of F A. A complete error budget for the nucleon isovector axial radius leads to r A 2 = 0.46(22)fm 2, withmore » a much larger uncertainty than determined in the original analyses. The quasielastic neutrino-neutron cross section is determined as σ(ν μn → μ -p)| Ev=1 GeV = 10.1(0.9)×10 -39cm 2. The propagation of nucleon-level constraints and uncertainties to nuclear cross sections is illustrated using MINERvA data and the GENIE event generator. Furthermore, these techniques can be readily extended to other amplitudes and processes.« less
Microcircuit radiation effects databank
NASA Technical Reports Server (NTRS)
1983-01-01
This databank is the collation of radiation test data submitted by many testers and serves as a reference for engineers who are concerned with and have some knowledge of the effects of the natural radiation environment on microcircuits. It contains radiation sensitivity results from ground tests and is divided into two sections. Section A lists total dose damage information, and section B lists single event upset cross sections, I.E., the probability of a soft error (bit flip) or of a hard error (latchup).
NASA Technical Reports Server (NTRS)
Nieman, R. A.
1971-01-01
The charge exchange cross sections for protons and various alkali atoms are calculated using the classical approximation of Gryzinski. It is assumed that the hydrogen atoms resulting from charge exchange exist in all possible excited states. Charge transfer collisions between protons and potassium as well as protons and sodium atoms are studied. The energy range investigated is between 4 and 30 keV. The theoretical calculations of the capture cross section and the cross section for the creation of metastable 2S hydrogen are compared to experimental values. Good quantitative agreement is found for the capture cross section but only qualitative agreement for the metastable cross section. Analysis of the Lyman alpha window in molecular oxygen suggests that measured values of the metastable cross section may be in error. Thick alkali target data are also presented. This allows the determination of the total electron loss cross section. Finally, some work was done with H2(+).
Jember, Abebaw; Hailu, Mignote; Messele, Anteneh; Demeke, Tesfaye; Hassen, Mohammed
2018-01-01
A medication error (ME) is any preventable event that may cause or lead to inappropriate medication use or patient harm. Voluntary reporting has a principal role in appreciating the extent and impact of medication errors. Thus, exploration of the proportion of medication error reporting and associated factors among nurses is important to inform service providers and program implementers so as to improve the quality of the healthcare services. Institution based quantitative cross-sectional study was conducted among 397 nurses from March 6 to May 10, 2015. Stratified sampling followed by simple random sampling technique was used to select the study participants. The data were collected using structured self-administered questionnaire which was adopted from studies conducted in Australia and Jordan. A pilot study was carried out to validate the questionnaire before data collection for this study. Bivariate and multivariate logistic regression models were fitted to identify factors associated with the proportion of medication error reporting among nurses. An adjusted odds ratio with 95% confidence interval was computed to determine the level of significance. The proportion of medication error reporting among nurses was found to be 57.4%. Regression analysis showed that sex, marital status, having made a medication error and medication error experience were significantly associated with medication error reporting. The proportion of medication error reporting among nurses in this study was found to be higher than other studies.
NASA Technical Reports Server (NTRS)
Anbar, A. D.; Allen, M.; Nair, H. A.
1993-01-01
We have investigated the impact of high resolution, temperature-dependent CO2 cross-section measurements, reported by Lewis and Carver (1983), on calculations of photodissociation rate coefficients in the Martian atmosphere. We find that the adoption of 50 A intervals for the purpose of computational efficiency results in errors in the calculated values for photodissociation of CO2, H2O, and O2 which are generally not above 10 percent, but as large as 20 percent in some instances. These are acceptably small errors, especially considering the uncertainties introduced by the large temperature dependence of the CO2 cross section. The inclusion of temperature-dependent CO2 cross sections is shown to lead to a decrease in the diurnally averaged rate of CO2 photodissociation as large as 33 percent at some altitudes, and increases of as much as 950 percent and 80 percent in the photodissociation rate coefficients of H2O and O2, respectively. The actual magnitude of the changes depends on the assumptions used to model the CO2 absorption spectrum at temperatures lower than the available measurements, and at wavelengths longward of 1970 A.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baldwin, G C
1974-04-30
Research on low energy electron collisions in gases by the time-of- flight velocity selection technique included, as a preliminary to total cross section measurements, investigations of the statistical and systematic errors inherent in the technique. In particular, thermal transpiration and instrumental fluctuation errors in manometry were investigated, and the results embodied in computer programs for data reduction. The instrumental system was improved to permit extended periods of data accumulation without manual attention. Total cross section measurements in helium, made prior to, and in molecular nitrogen, made after the supporting work was completed, are reported. The total cross sec tion ofmore » helium is found to be higher than reported in previous beam determinations. That of nitrogen is found to be structureless at low energies. (auth)« less
Total absorption and photoionization cross sections of water vapor between 100 and 1000 A
NASA Technical Reports Server (NTRS)
Haddad, G. N.; Samson, J. A. R.
1986-01-01
Absolute photoabsorption and photoionization cross sections of water vapor are reported at a large number of discrete wavelengths between 100 and 1000 A with an estimate error of + or - 3 percent in regions free from any discrete structure. The double ionization chamber technique utilized is described. Recent calculations are shown to be in reasonable agreement with the present data.
Gamma heating in reflector heat shield of gas core reactor
NASA Technical Reports Server (NTRS)
Lofthouse, J. H.; Kunze, J. F.; Young, T. E.; Young, R. C.
1972-01-01
Heating rate measurements made in a mock-up of a BeO heat shield for a gas core nuclear rocket engine yields results nominally a factor of two greater than calculated by two different methods. The disparity is thought to be caused by errors in neutron capture cross sections and gamma spectra from the low cross-section elements, D, O, and Be.
Medical errors in primary care clinics – a cross sectional study
2012-01-01
Background Patient safety is vital in patient care. There is a lack of studies on medical errors in primary care settings. The aim of the study is to determine the extent of diagnostic inaccuracies and management errors in public funded primary care clinics. Methods This was a cross-sectional study conducted in twelve public funded primary care clinics in Malaysia. A total of 1753 medical records were randomly selected in 12 primary care clinics in 2007 and were reviewed by trained family physicians for diagnostic, management and documentation errors, potential errors causing serious harm and likelihood of preventability of such errors. Results The majority of patient encounters (81%) were with medical assistants. Diagnostic errors were present in 3.6% (95% CI: 2.2, 5.0) of medical records and management errors in 53.2% (95% CI: 46.3, 60.2). For management errors, medication errors were present in 41.1% (95% CI: 35.8, 46.4) of records, investigation errors in 21.7% (95% CI: 16.5, 26.8) and decision making errors in 14.5% (95% CI: 10.8, 18.2). A total of 39.9% (95% CI: 33.1, 46.7) of these errors had the potential to cause serious harm. Problems of documentation including illegible handwriting were found in 98.0% (95% CI: 97.0, 99.1) of records. Nearly all errors (93.5%) detected were considered preventable. Conclusions The occurrence of medical errors was high in primary care clinics particularly with documentation and medication errors. Nearly all were preventable. Remedial intervention addressing completeness of documentation and prescriptions are likely to yield reduction of errors. PMID:23267547
Best estimate of luminal cross-sectional area of coronary arteries from angiograms
NASA Technical Reports Server (NTRS)
Lee, P. L.; Selzer, R. H.
1988-01-01
We have reexamined the problem of estimating the luminal area of an elliptically-shaped coronary artery cross section from two or more radiographic diameter measurements. The expected error is found to be much smaller than the maximum potential error. In the cae of two orthogonal views, closed form expressions have been derived for calculating the area and the uncertainty. Assuming that the underlying ellipse has limited ellipticity (major/minor axis ratio less than five), it is shown that the average uncertainty in the area is less than 14 percent. When more than two views are available, we suggest using a least-squares fit method to extract all available information from the data.
Estimation of the sea surface's two-scale backscatter parameters
NASA Technical Reports Server (NTRS)
Wentz, F. J.
1978-01-01
The relationship between the sea-surface normalized radar cross section and the friction velocity vector is determined using a parametric two-scale scattering model. The model parameters are found from a nonlinear maximum likelihood estimation. The estimation is based on aircraft scatterometer measurements and the sea-surface anemometer measurements collected during the JONSWAP '75 experiment. The estimates of the ten model parameters converge to realistic values that are in good agreement with the available oceanographic data. The rms discrepancy between the model and the cross section measurements is 0.7 db, which is the rms sum of a 0.3 db average measurement error and a 0.6 db modeling error.
Paediatric in-patient prescribing errors in Malaysia: a cross-sectional multicentre study.
Khoo, Teik Beng; Tan, Jing Wen; Ng, Hoong Phak; Choo, Chong Ming; Bt Abdul Shukor, Intan Nor Chahaya; Teh, Siao Hean
2017-06-01
Background There is a lack of large comprehensive studies in developing countries on paediatric in-patient prescribing errors in different settings. Objectives To determine the characteristics of in-patient prescribing errors among paediatric patients. Setting General paediatric wards, neonatal intensive care units and paediatric intensive care units in government hospitals in Malaysia. Methods This is a cross-sectional multicentre study involving 17 participating hospitals. Drug charts were reviewed in each ward to identify the prescribing errors. All prescribing errors identified were further assessed for their potential clinical consequences, likely causes and contributing factors. Main outcome measures Incidence, types, potential clinical consequences, causes and contributing factors of the prescribing errors. Results The overall prescribing error rate was 9.2% out of 17,889 prescribed medications. There was no significant difference in the prescribing error rates between different types of hospitals or wards. The use of electronic prescribing had a higher prescribing error rate than manual prescribing (16.9 vs 8.2%, p < 0.05). Twenty eight (1.7%) prescribing errors were deemed to have serious potential clinical consequences and 2 (0.1%) were judged to be potentially fatal. Most of the errors were attributed to human factors, i.e. performance or knowledge deficit. The most common contributing factors were due to lack of supervision or of knowledge. Conclusions Although electronic prescribing may potentially improve safety, it may conversely cause prescribing errors due to suboptimal interfaces and cumbersome work processes. Junior doctors need specific training in paediatric prescribing and close supervision to reduce prescribing errors in paediatric in-patients.
Measurement of electron impact collisional excitation cross sections of Ni to Ge-like gold
May, M. J.; Beiersdorfer, P.; Jordan, N.; ...
2017-03-01
We have measured the collisional excitation cross sections for the 3d→4f and 3d→5f excitations in Au ions near the Ni-like charge state by using beam plasmas created in the Livermore electron beam ion trap EBIT-I. The cross sections have been experimentally determined at approximately 1, 2 and 3 keV above the threshold energy, ET, for the 3d→4f excitations (ET ~2.5 keV) and at approximately 0.1, 1 and 2 keV above the threshold energy for the 3d→5f excitations (ET ~3.3 keV). The cross section measurements were made possible by using the GSFC x-ray microcalorimeter at the Livermore EBIT facility. The absolutemore » cross sections are determined from the ratio of the intensity of the collisionally excited bound-bound transitions to the intensity of the radiative recombination lines produced in EBIT-I plasmas. The effects of polarization and Auger decay channels are accounted for in the cross section determination. Measured cross sections are compared with those from HULLAC, DWS and FAC calculations. Finally, the measurements demonstrate that some errors exist in the calculated excitation cross sections.« less
Measurement of electron impact collisional excitation cross sections of Ni to Ge-like gold
NASA Astrophysics Data System (ADS)
May, M. J.; Beiersdorfer, P.; Jordan, N.; Scofield, J. H.; Reed, K. J.; Brown, G. V.; Hansen, S. B.; Porter, F. S.; Kelley, R.; Kilbourne, C. A.; Boyce, K. R.
2017-03-01
We have measured the collisional excitation cross sections for the 3d→4f and 3d→5f excitations in Au ions near the Ni-like charge state by using beam plasmas created in the Livermore electron beam ion trap EBIT-I. The cross sections have been experimentally determined at approximately 1, 2 and 3 keV above the threshold energy, ET, for the 3d→4f excitations (ET ˜ 2.5 keV) and at approximately 0.1, 1 and 2 keV above the threshold energy for the 3d→5f excitations (ET ˜ 3.3 keV). The cross section measurements were made possible by using the GSFC x-ray microcalorimeter at the Livermore EBIT facility. The absolute cross sections are determined from the ratio of the intensity of the collisionally excited bound-bound transitions to the intensity of the radiative recombination lines produced in EBIT-I plasmas. The effects of polarization and Auger decay channels are accounted for in the cross section determination. Measured cross sections are compared with those from HULLAC, DWS and FAC calculations. The measurements demonstrate that some errors exist in the calculated excitation cross sections.
Topping, David J.; Rubin, David M.; Wright, Scott A.; Melis, Theodore S.
2011-01-01
Several common methods for measuring suspended-sediment concentration in rivers in the United States use depth-integrating samplers to collect a velocity-weighted suspended-sediment sample in a subsample of a river cross section. Because depth-integrating samplers are always moving through the water column as they collect a sample, and can collect only a limited volume of water and suspended sediment, they collect only minimally time-averaged data. Four sources of error exist in the field use of these samplers: (1) bed contamination, (2) pressure-driven inrush, (3) inadequate sampling of the cross-stream spatial structure in suspended-sediment concentration, and (4) inadequate time averaging. The first two of these errors arise from misuse of suspended-sediment samplers, and the third has been the subject of previous study using data collected in the sand-bedded Middle Loup River in Nebraska. Of these four sources of error, the least understood source of error arises from the fact that depth-integrating samplers collect only minimally time-averaged data. To evaluate this fourth source of error, we collected suspended-sediment data between 1995 and 2007 at four sites on the Colorado River in Utah and Arizona, using a P-61 suspended-sediment sampler deployed in both point- and one-way depth-integrating modes, and D-96-A1 and D-77 bag-type depth-integrating suspended-sediment samplers. These data indicate that the minimal duration of time averaging during standard field operation of depth-integrating samplers leads to an error that is comparable in magnitude to that arising from inadequate sampling of the cross-stream spatial structure in suspended-sediment concentration. This random error arising from inadequate time averaging is positively correlated with grain size and does not largely depend on flow conditions or, for a given size class of suspended sediment, on elevation above the bed. Averaging over time scales >1 minute is the likely minimum duration required to result in substantial decreases in this error. During standard two-way depth integration, a depth-integrating suspended-sediment sampler collects a sample of the water-sediment mixture during two transits at each vertical in a cross section: one transit while moving from the water surface to the bed, and another transit while moving from the bed to the water surface. As the number of transits is doubled at an individual vertical, this error is reduced by ~30 percent in each size class of suspended sediment. For a given size class of suspended sediment, the error arising from inadequate sampling of the cross-stream spatial structure in suspended-sediment concentration depends only on the number of verticals collected, whereas the error arising from inadequate time averaging depends on both the number of verticals collected and the number of transits collected at each vertical. Summing these two errors in quadrature yields a total uncertainty in an equal-discharge-increment (EDI) or equal-width-increment (EWI) measurement of the time-averaged velocity-weighted suspended-sediment concentration in a river cross section (exclusive of any laboratory-processing errors). By virtue of how the number of verticals and transits influences the two individual errors within this total uncertainty, the error arising from inadequate time averaging slightly dominates that arising from inadequate sampling of the cross-stream spatial structure in suspended-sediment concentration. Adding verticals to an EDI or EWI measurement is slightly more effective in reducing the total uncertainty than adding transits only at each vertical, because a new vertical contributes both temporal and spatial information. However, because collection of depth-integrated samples at more transits at each vertical is generally easier and faster than at more verticals, addition of a combination of verticals and transits is likely a more practical approach to reducing the total uncertainty in most field situatio
Proton-nucleus total inelastic cross sections - An empirical formula for E greater than 10 MeV
NASA Technical Reports Server (NTRS)
Letaw, J. R.; Silberberg, R.; Tsao, C. H.
1983-01-01
An empirical formula for the total inelastic cross section of protons on nuclei with charge greater than 1 is presented. The formula is valid with a varying degree of accuracy down to proton energies of 10 MeV. At high energies (equal to or greater than 2 GeV) the formula reproduces experimental data to within reported errors (about 2%).
Bastawrous, Andrew; Mathenge, Wanjiku; Foster, Allen; Kuper, Hannah
2013-10-01
A cross-sectional study was undertaken in Nakuru, Kenya to assess the prevalence of refractive error and the spectacle coverage in a population aged ≥50 years. Of the 5,010 subjects who were eligible, 4,414 underwent examination (response rate 88.1 %). LogMAR visual acuity was assessed in all participants and refractive error was measured in both eyes using a Topcon auto refractor RM8800. Detailed interviews were undertaken and ownership of spectacles was assessed. Refractive error was responsible for 51.7 % of overall visual impairment (VI), 85.3 % (n = 191) of subjects with mild VI, 42.7 % (n = 152) of subjects with moderate VI, 16.7 % (n = 3) of subjects with severe VI and no cases of blindness. Myopia was more common than hyperopia affecting 59.5 % of those with refractive error compared to 27.4 % for hyperopia. High myopia (<-5.0 DS) was also more common than extreme hyperopia (>+5.0 DS). Of those who needed distance spectacles (spectacle coverage), 25.5 % owned spectacles. In conclusion, the oldest, most poor and least educated are most likely to have no spectacles and they should be specifically targeted when refractive services are put in place.
3He(γ,pd) cross sections with tagged photons below the Δ resonance
NASA Astrophysics Data System (ADS)
Kolb, N. R.; Cairns, E. B.; Hackett, E. D.; Korkmaz, E.; Nakano, T.; Opper, A. K.; Quraan, M. A.; Rodning, N. L.; Rozon, F. M.; Asai, J.; Feldman, G.; Hallin, E.; O'rielly, G. V.; Pywell, R. E.; Skopik, D. M.
1994-05-01
The reaction cross section for 3He(γ,pd) has been measured using the Saskatchewan-Alberta Large Acceptance Detector (SALAD) with tagged photons in the energy range from 166 to 213 MeV. The energy and angle of the proton and the deuteron were measured with SALAD while the tagger determined the photon energy. Differential cross sections have been determined for 40°<θ*p<150°. The results are in agreement with the Bonn and Saclay photodisintegration measurements. The most recent photodisintegration measurement performed at Bates is higher by a factor of 1.3, which is just within the combined errors of the experiments. The proton capture results differ by a factor of 1.7 from the present experiment. Comparisons are made with microscopic calculations of the cross sections.
Neutrino-nucleus cross sections for oscillation experiments
NASA Astrophysics Data System (ADS)
Katori, Teppei; Martini, Marco
2018-01-01
Neutrino oscillations physics is entering an era of high precision. In this context, accelerator-based neutrino experiments need a reduction in systematic errors to the level of a few percent. Today, one of the most important sources of systematic errors are neutrino-nucleus cross sections which, in the energy region of hundreds of MeV to a few GeV, are known to a precision not exceeding 20%. In this article we review the present experimental and theoretical knowledge of neutrino-nucleus interaction physics. After introducing neutrino-oscillation physics and accelerator-based neutrino experiments, we give an overview of general aspects of neutrino-nucleus cross sections, from both the theoretical and experimental point of view. Then, we focus on these cross sections in different reaction channels. We start with the quasi-elastic and quasi-elastic-like cross section, placing a special emphasis on the multinucleon emission channel, which has attracted a lot of attention in the last few years. We review the main aspects of the different microscopic models for this channel by discussing analogies and the differences among them. The discussion is always driven by a comparison with the experimental data. We then consider the one-pion production channel where agreement between data and theory remains highly unsatisfactory. We describe how to interpret pion data, and then analyze, in particular, the puzzle related to the difficulty of theoretical models and Monte Carlo to simultaneously describe MiniBooNE and MINERvA experimental results. Inclusive cross sections are also discussed, as well as the comparison between the {ν }μ and {ν }e cross sections, relevant for the charge-conjugation-parity violation experiments. The impact of nuclear effects on the reconstruction of neutrino energy and on the determination of the neutrino-oscillation parameters is also reviewed. Finally, we look to the future by discussing projects and efforts in relation to future detectors, beams, and analysis.
Ammari, Maha Al; Sultana, Khizra; Yunus, Faisal; Ghobain, Mohammed Al; Halwan, Shatha M. Al
2016-01-01
Objectives: To assess the proportion of critical errors committed while demonstrating the inhaler technique in hospitalized patients diagnosed with asthma and chronic obstructive pulmonary disease (COPD). Methods: This cross-sectional observational study was conducted in 47 asthmatic and COPD patients using inhaler devices. The study took place at King Abdulaziz Medical City, Riyadh, Saudi Arabia between September and December 2013. Two pharmacists independently assessed inhaler technique with a validated checklist. Results: Seventy percent of patients made at least one critical error while demonstrating their inhaler technique, and the mean number of critical errors per patient was 1.6. Most patients used metered dose inhaler (MDI), and 73% of MDI users and 92% of dry powder inhaler users committed at least one critical error. Conclusion: Inhaler technique in hospitalized Saudi patients was inadequate. Health care professionals should understand the importance of reassessing and educating patients on a regular basis for inhaler technique, recommend the use of a spacer when needed, and regularly assess and update their own inhaler technique skills. PMID:27146622
Fission cross section of 239Th and 232Th relative to 235U
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meadows, J. W.
1979-01-01
The fission cross sections of /sup 230/Th and /sup 232/Th were measured relative to /sup 235/U from near threshold to near 10 MeV. The weights of the thorium samples were determined by isotopic dilution. The weight of the uranium deposit was based on specific activity measurements of a /sup 234/U-/sup 235/U mixture and low geometry alpha counting. Corrections were made for thermal background, loss of fragments in the deposits, neutron scattering in the detector assembly, sample geometry, sample composition and the spectrum of the neutron source. Generally the systematic errors were approx. 1%. The combined systematic and statistical errors weremore » typically 1.5%. 17 references.« less
Measurement of differential cross section of D(3He,p)4He from 0.8 MeV to 3.6 MeV
NASA Astrophysics Data System (ADS)
Zhu, J. P.; Xiao, X.; Yan, S.; Gao, Y.; Xue, J. M.; Wang, Y. G.
2017-12-01
Precise knowledge of the nuclear reaction cross-section is crucial for nuclear reaction analysis methods and its applications. In order to apply nuclear reaction analysis methods to Plasma Facing Materials studies on 4.5 MV electrostatic accelerator at Peking University, differential cross-section for d(3He,p) α at several backward angles was measured with a relative error about ± 6.2 % , gives detailed information at the laboratory angle of 135° from 800 keV to 3600 keV, as well as a rough angular distribution from 130° to 160°.
Heavy Ion Irradiation Fluence Dependence for Single-Event Upsets of NAND Flash Memory
NASA Technical Reports Server (NTRS)
Chen, Dakai; Wilcox, Edward; Ladbury, Raymond; Kim, Hak; Phan, Anthony; Seidleck, Christina; LaBel, Kenneth
2016-01-01
We investigated the single-event effect (SEE) susceptibility of the Micron 16 nm NAND flash, and found the single-event upset (SEU) cross section varied inversely with fluence. The SEU cross section decreased with increasing fluence. We attribute the effect to the variable upset sensitivities of the memory cells. The current test standards and procedures assume that SEU follow a Poisson process and do not take into account the variability in the error rate with fluence. Therefore, heavy ion irradiation of devices with variable upset sensitivity distribution using typical fluence levels may underestimate the cross section and on-orbit event rate.
Mental visualization of objects from cross-sectional images
Wu, Bing; Klatzky, Roberta L.; Stetten, George D.
2011-01-01
We extended the classic anorthoscopic viewing procedure to test a model of visualization of 3D structures from 2D cross-sections. Four experiments were conducted to examine key processes described in the model, localizing cross-sections within a common frame of reference and spatiotemporal integration of cross sections into a hierarchical object representation. Participants used a hand-held device to reveal a hidden object as a sequence of cross-sectional images. The process of localization was manipulated by contrasting two displays, in-situ vs. ex-situ, which differed in whether cross sections were presented at their source locations or displaced to a remote screen. The process of integration was manipulated by varying the structural complexity of target objects and their components. Experiments 1 and 2 demonstrated visualization of 2D and 3D line-segment objects and verified predictions about display and complexity effects. In Experiments 3 and 4, the visualized forms were familiar letters and numbers. Errors and orientation effects showed that displacing cross-sectional images to a remote display (ex-situ viewing) impeded the ability to determine spatial relationships among pattern components, a failure of integration at the object level. PMID:22217386
Bankfull characteristics of Ohio streams and their relation to peak streamflows
Sherwood, James M.; Huitger, Carrie A.
2005-01-01
Regional curves, simple-regression equations, and multiple-regression equations were developed to estimate bankfull width, bankfull mean depth, bankfull cross-sectional area, and bankfull discharge of rural, unregulated streams in Ohio. The methods are based on geomorphic, basin, and flood-frequency data collected at 50 study sites on unregulated natural alluvial streams in Ohio, of which 40 sites are near streamflow-gaging stations. The regional curves and simple-regression equations relate the bankfull characteristics to drainage area. The multiple-regression equations relate the bankfull characteristics to drainage area, main-channel slope, main-channel elevation index, median bed-material particle size, bankfull cross-sectional area, and local-channel slope. Average standard errors of prediction for bankfull width equations range from 20.6 to 24.8 percent; for bankfull mean depth, 18.8 to 20.6 percent; for bankfull cross-sectional area, 25.4 to 30.6 percent; and for bankfull discharge, 27.0 to 78.7 percent. The simple-regression (drainage-area only) equations have the highest average standard errors of prediction. The multiple-regression equations in which the explanatory variables included drainage area, main-channel slope, main-channel elevation index, median bed-material particle size, bankfull cross-sectional area, and local-channel slope have the lowest average standard errors of prediction. Field surveys were done at each of the 50 study sites to collect the geomorphic data. Bankfull indicators were identified and evaluated, cross-section and longitudinal profiles were surveyed, and bed- and bank-material were sampled. Field data were analyzed to determine various geomorphic characteristics such as bankfull width, bankfull mean depth, bankfull cross-sectional area, bankfull discharge, streambed slope, and bed- and bank-material particle-size distribution. The various geomorphic characteristics were analyzed by means of a combination of graphical and statistical techniques. The logarithms of the annual peak discharges for the 40 gaged study sites were fit by a Pearson Type III frequency distribution to develop flood-peak discharges associated with recurrence intervals of 2, 5, 10, 25, 50, and 100 years. The peak-frequency data were related to geomorphic, basin, and climatic variables by multiple-regression analysis. Simple-regression equations were developed to estimate 2-, 5-, 10-, 25-, 50-, and 100-year flood-peak discharges of rural, unregulated streams in Ohio from bankfull channel cross-sectional area. The average standard errors of prediction are 31.6, 32.6, 35.9, 41.5, 46.2, and 51.2 percent, respectively. The study and methods developed are intended to improve understanding of the relations between geomorphic, basin, and flood characteristics of streams in Ohio and to aid in the design of hydraulic structures, such as culverts and bridges, where stability of the stream and structure is an important element of the design criteria. The study was done in cooperation with the Ohio Department of Transportation and the U.S. Department of Transportation, Federal Highway Administration.
NASA Astrophysics Data System (ADS)
Aubert, J. J.; Bassompierre, G.; Becks, K. H.; Benchouk, C.; Best, C.; Bird, I. G.; Böhm, E.; de Bouard, X.; Brasse, F. W.; Broll, C.; Brown, S.; Carr, J.; Clifft, R.; Cobb, J. H.; Coignet, G.; Combley, F.; Court, G. R.; D'Agostini, G.; Dau, W. D.; Davies, J. K.; Déclais, Y.; Dosselli, U.; Drees, J.; Edwards, A.; Edwards, M.; Favier, J.; Ferrero, M. I.; Flauger, W.; Forsbach, H.; Gabathuler, E.; Gamet, R.; Gayler, J.; Gerhardt, V.; Gössling, C.; Haas, J.; Hamacher, K.; Hayman, P.; Henckes, M.; Korbel, V.; Landgraf, U.; Leenen, M.; Maire, M.; Mohr, W.; Montgomery, H. E.; Moser, K.; Mount, R. P.; Nagy, E.; Nassalski, J.; Norton, P. R.; McNicholas, J.; Osborne, A. M.; Payre, P.; Peroni, C.; Pessard, H.; Pietrzyk, U.; Rith, K.; Schneegans, M.; Sloan, T.; Stier, H. E.; Stockhausen, W.; Thénard, J. M.; Thompson, J. C.; Urban, L.; Villers, M.; Wahlen, H.; Walley, M.; Williams, D.; Williams, W. S. C.; Williamson, J.; Wimpenny, S.
1985-03-01
The cross sections for J/ψ production have been measured in interactions of 280 GeV μ+ on hydrogen and deuterium (H, D) and also in interactions of 250 GeV μ+ on iron. The single-nucleon cross sections in iron are found to be larger than those in H, D. The mean ratio of the iron to H, D photoproduction cross sections in the range 60 < v < 200 GeV is 1.45 +/-0.12 (statistical) +/-0.22 (systematic error). Within the framework of the photon-gluon fusion model, this indicates that the gluon density per nucleon is ~45% larger in iron than in H, D in the range 0.026 < x < 0.085, on a mass scale Q2eff ~M2J/ψ.
Reducing Uncertainties in Neutron-Induced Fission Cross Sections Using a Time Projection Chamber
NASA Astrophysics Data System (ADS)
Manning, Brett; Niffte Collaboration
2015-10-01
Neutron-induced fission cross sections for actinides have long been of great interest for nuclear energy and stockpile stewardship. Traditionally, measurements were performed using fission chambers which provided limited information about the detected fission events. For the case of 239Pu(n,f), sensitivity studies have shown a need for more precise measurements. Recently the Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) has developed the fission Time Projection Chamber (fissionTPC) to measure fission cross sections to better than 1% uncertainty by providing 3D tracking of fission fragments. The fissionTPC collected data to calculate the 239Pu(n,f) cross section at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center during the 2014 run cycle. Preliminary analysis has been focused on studying particle identification and target and beam non-uniformities to reduce the uncertainty on the cross section. Additionally, the collaboration is investigating other systematic errors that could not be well studied with a traditional fission chamber. LA-UR-15-24906.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darling, Christopher Lynn
By determining the production cross sections for heavy flavor hadrons, we test the theoretical predictions from perturhative quantum chroma-dynamics (QCD). In the case of pion induced beauty production, the few published results do not resolve the issue of the applicability of perturbative QCD. This analysis is undertaken in order to help resolve this situation. We determine the total beauty and charm production cross sections using an analysis of single electron decay products. We extract the cross sections per nucleon from the two-dimensional distribution of electron p versus impact parameter ( d) to the primary vertex. We place an upper limit on the beauty production cross section of σ bmore » $$\\bar{b}$$ < 105 nb at the 90% confidence level, where the limit includes both statistical and systematic errors. The charm production cross section is determined to be σ cc = 13.9$$+2.4/atop{-2.3}$$ (stat) ± 1.8 (syst) μ.b, which is in good agreement with next-to-leading order QCD predictions and other measurements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darling, Christopher Lynn
By determining the production cross sections for heavy flavor hadrons, we test the theoretical predictions from perturhative quantum chroma-dynamics (QCD). In the case of pion induced beauty production, the few published results do not resolve the issue of the applicability of perturbative QCD. This analysis is undertaken in order to help resolve this situation. We determine the total beauty and charm production cross sections using an analysis of single electron decay products. We extract the cross sections per nucleon from the two-dimensional distribution of electronmore » $$p^2_{\\tau}$$ versus impact parameter (d) to the primary vertex. We place an upper limit on the beauty production cross section of $$\\sigma_{b\\overline{b}}$$ < 105 nb at the 90% confidence level, where the limit includes both statistical and systematic errors. The charm production cross section is determined to be $$\\sigma_{c\\overline{c}} = 13.9 ^{+2.4}_{-2.3}$$(stat)±l.8(syst) $$\\mu b$$, which is in good agreement with next-to-leading order QCD predictions and other measurements.« less
Microcircuit radiation effects databank
NASA Technical Reports Server (NTRS)
1983-01-01
Radiation test data submitted by many testers is collated to serve as a reference for engineers who are concerned with and have some knowledge of the effects of the natural radiation environment on microcircuits. Total dose damage information and single event upset cross sections, i.e., the probability of a soft error (bit flip) or of a hard error (latchup) are presented.
Hwang, Jee-In; Park, Hyeoun-Ae
2017-12-01
Healthcare professionals' systems thinking is emphasized for patient safety. To report nurses' systems thinking competency, and its relationship with medical error reporting and the occurrence of adverse events. A cross-sectional survey using a previously validated Systems Thinking Scale (STS), was conducted. Nurses from two teaching hospitals were invited to participate in the survey. There were 407 (60.3%) completed surveys. The mean STS score was 54.5 (SD 7.3) out of 80. Nurses with higher STS scores were more likely to report medical errors (odds ratio (OR) = 1.05; 95% confidence interval (CI) = 1.02-1.08) and were less likely to be involved in the occurrence of adverse events (OR = 0.96; 95% CI = 0.93-0.98). Nurses showed moderate systems thinking competency. Systems thinking was a significant factor associated with patient safety. Impact Statement: The findings of this study highlight the importance of enhancing nurses' systems thinking capacity to promote patient safety.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meadows, J W
1983-10-01
Earlier results from the measurements, at this Laboratory, of the fission cross sections of /sup 230/Th, /sup 232/Th, /sup 233/U, /sup 234/U, /sup 236/U, /sup 238/U, /sup 237/Np, /sup 239/Pu, /sup 240/Pu, and /sup 242/Pu relative to /sup 235/U are reviewed with revisions to include changes in data processing procedures, alpha half lives and thermal fission cross sections. Some new data have also been included. The current experimental methods and procedures and the sample assay methods are described in detail and the sources of error are presented in a systematic manner. 38 references.
Rayleigh scattering cross-section measurements of nitrogen, argon, oxygen and air
NASA Astrophysics Data System (ADS)
Thalman, Ryan; Zarzana, Kyle J.; Tolbert, Margaret A.; Volkamer, Rainer
2014-11-01
Knowledge about Rayleigh scattering cross sections is relevant to predictions about radiative transfer in the atmosphere, and needed to calibrate the reflectivity of mirrors that are used in high-finesse optical cavities to measure atmospheric trace gases and aerosols. In this work we have measured the absolute Rayleigh scattering cross-section of nitrogen at 405.8 and 532.2 nm using cavity ring-down spectroscopy (CRDS). Further, multi-spectral measurements of the scattering cross-sections of argon, oxygen and air are presented relative to that of nitrogen from 350 to 660 nm using Broadband Cavity Enhanced Spectroscopy (BBCES). The reported measurements agree with refractive index based theory within 0.2±0.4%, and have an absolute accuracy of better than 1.3%. Our measurements expand the spectral range over which Rayleigh scattering cross section measurements of argon, oxygen and air are available at near-ultraviolet wavelengths. The expressions used to represent the Rayleigh scattering cross-section in the literature are evaluated to assess how uncertainties affect quantities measured by cavity enhanced absorption spectroscopic (CEAS) techniques. We conclude that Rayleigh scattering cross sections calculated from theory provide accurate data within very low error bounds, and are suited well to calibrate CEAS measurements of atmospheric trace gases and aerosols.
A three-microphone acoustic reflection technique using transmitted acoustic waves in the airway.
Fujimoto, Yuki; Huang, Jyongsu; Fukunaga, Toshiharu; Kato, Ryo; Higashino, Mari; Shinomiya, Shohei; Kitadate, Shoko; Takahara, Yutaka; Yamaya, Atsuyo; Saito, Masatoshi; Kobayashi, Makoto; Kojima, Koji; Oikawa, Taku; Nakagawa, Ken; Tsuchihara, Katsuma; Iguchi, Masaharu; Takahashi, Masakatsu; Mizuno, Shiro; Osanai, Kazuhiro; Toga, Hirohisa
2013-10-15
The acoustic reflection technique noninvasively measures airway cross-sectional area vs. distance functions and uses a wave tube with a constant cross-sectional area to separate incidental and reflected waves introduced into the mouth or nostril. The accuracy of estimated cross-sectional areas gets worse in the deeper distances due to the nature of marching algorithms, i.e., errors of the estimated areas in the closer distances accumulate to those in the further distances. Here we present a new technique of acoustic reflection from measuring transmitted acoustic waves in the airway with three microphones and without employing a wave tube. Using miniaturized microphones mounted on a catheter, we estimated reflection coefficients among the microphones and separated incidental and reflected waves. A model study showed that the estimated cross-sectional area vs. distance function was coincident with the conventional two-microphone method, and it did not change with altered cross-sectional areas at the microphone position, although the estimated cross-sectional areas are relative values to that at the microphone position. The pharyngeal cross-sectional areas including retropalatal and retroglossal regions and the closing site during sleep was visualized in patients with obstructive sleep apnea. The method can be applicable to larger or smaller bronchi to evaluate the airspace and function in these localized airways.
7Li(p,n)7Be and 12C(p,n)12N reactions at 200, 300, and 400 MeV
NASA Astrophysics Data System (ADS)
Watson, J. W.; Pourang, R.; Abegg, R.; Alford, W. P.; Celler, A.; El-Kateb, S.; Frekers, D.; Häusser, O.; Helmer, R.; Henderson, R.; Hicks, K.; Jackson, K. P.; Jeppesen, R. G.; Miller, C. A.; Vetterli, M.; Yen, S.; Zafiratos, C. D.
1989-07-01
At 200, 300, and 400 MeV bombarding energies, we measured cross section angular distributions for the 7Li(p,n)7Be(g.s.+0.43 MeV) reaction and 0° cross sections for the 12C(p,n)12N(g.s.) reaction. Systematics of these reactions are presented. The center-of-mass cross section for the 7Li(p,n)7Be(g.s.+0.43 MeV) reaction, when plotted as a function of momentum transfer, is nearly independent of energy. The laboratory cross section for this reaction at 0° in the energy range from 60 to 400 MeV is also independent of energy, having a constant value, to within experimental errors, of 35.5 mb/sr with an estimated uncertainty of +/-1.5 mb/sr.
NASA Astrophysics Data System (ADS)
Miranda, J.; Lapicki, G.
2018-01-01
A compilation of experimental L-shell X-ray production and ionization cross sections induced by proton impact was published recently (Miranda and Lapicki, 2014), collecting 15 439 experimental cross sections. The database covers an energy range from 10 keV to 1 GeV, and targets from 10Ne to 95Am. A correction to several tabulated values that were in error, as well as an update including new data published after 2012 and older references not found previously are given in the present work. The updated data base increased the total number of experimental cross sections by 3.1% to 15 921. A new analysis of the total number of experimental points per year shows that the possible saturation in the cumulative total number of data is increased to 15 950 ± 110 points.
Theoretical and Experimental K+ + Nucleus Total and Reaction Cross Sections from the KDP-RIA Model
NASA Astrophysics Data System (ADS)
Kerr, L. K.; Clark, B. C.; Hama, S.; Ray, L.; Hoffmann, G. W.
2000-02-01
The 5-dimensional spin-0 form of the Kemmer-Duffin-Petiau (KDP) equation is used to calculate scattering observables [elastic differential cross sections (dσ / dΩ), total cross sections (σ Tot ), and total reaction cross sections (σ Reac )] and to deduce σ Tot and σReac from transmission data for K+ + 6Li, 12C, 28Si and 40Ca at several momenta in the range 488 - 714 MeV / c. Realistic uncertainties are generated for the theoretical predictions. These errors, mainly due to uncertainties associated with the elementary K+ + nucleon amplitudes, are large, which may account for some of the disagreement between experimental and theoretical σTot and σReac. The results suggest that the K+ + nucleon amplitudes need to be much better determined before further improvement in the understanding of these data can occur.
Estimating Single-Event Logic Cross Sections in Advanced Technologies
NASA Astrophysics Data System (ADS)
Harrington, R. C.; Kauppila, J. S.; Warren, K. M.; Chen, Y. P.; Maharrey, J. A.; Haeffner, T. D.; Loveless, T. D.; Bhuva, B. L.; Bounasser, M.; Lilja, K.; Massengill, L. W.
2017-08-01
Reliable estimation of logic single-event upset (SEU) cross section is becoming increasingly important for predicting the overall soft error rate. As technology scales and single-event transient (SET) pulse widths shrink to widths on the order of the setup-and-hold time of flip-flops, the probability of latching an SET as an SEU must be reevaluated. In this paper, previous assumptions about the relationship of SET pulsewidth to the probability of latching an SET are reconsidered and a model for transient latching probability has been developed for advanced technologies. A method using the improved transient latching probability and SET data is used to predict logic SEU cross section. The presented model has been used to estimate combinational logic SEU cross sections in 32-nm partially depleted silicon-on-insulator (SOI) technology given experimental heavy-ion SET data. Experimental SEU data show good agreement with the model presented in this paper.
Evaluation of ship-based sediment flux measurements by ADCPs in tidal flows
NASA Astrophysics Data System (ADS)
Becker, Marius; Maushake, Christian; Grünler, Steffen; Winter, Christian
2017-04-01
In the past decades acoustic backscatter calibration developed into a frequently applied technique to measure fluxes of suspended sediments in rivers and estuaries. Data is mainly acquired using single-frequency profiling devices, such as ADCPs. In this case, variations of acoustic particle properties may have a significant impact on the calibration with respect to suspended sediment concentration, but associated effects are rarely considered. Further challenges regarding flux determination arise from incomplete vertical and lateral coverage of the cross-section, and the small ratio of the residual transport to the tidal transport, depending on the tidal prism. We analyzed four sets of 13h cross-sectional ADCP data, collected at different locations in the range of the turbidity zone of the Weser estuary, North Sea, Germany. Vertical LISST, OBS and CTD measurements were taken very hour. During the calibration sediment absorption was taken into account. First, acoustic properties were estimated using LISST particle size distributions. Due to the tidal excursion and displacement of the turbidity zone, acoustic properties of particles changed during the tidal cycle, at all locations. Applying empirical functions, the lowest backscattering cross-section and highest sediment absorption coefficient were found in the center of the turbidity zone. Outside the tidally averaged location of the turbidity zone, changes of acoustic parameters were caused mainly by advection. In the turbidity zone, these properties were also affected by settling and entrainment, inducing vertical differences and systematic errors in concentration. In general, due to the iterative correction of sediment absorption along the acoustic path, local errors in concentration propagate and amplify exponentially. Based on reference concentration obtained from water samples and OBS data, we quantified these errors and their effect on cross-sectional averaged concentration and sediment flux. We found that errors are effectively decreased by applying calibration parameters interpolated in time, and by an optimization of the sediment absorption coefficient. We further discuss practical aspects of residual flux determination in tidal environments and of measuring strategies in relation to site-specific tidal dynamics.
Stopping cross sections for 0.25-3.0-MeV He-4 ions in cadmium sulfide
NASA Technical Reports Server (NTRS)
Miller, W. E.; Hutchby, J. A.
1975-01-01
Stopping cross sections of He-4 ions with energies between 0.25 and 3.0 MeV have been measured for cadmium sulfide with a probable error of plus or minus 7% to 8%. The experimental method utilized the Rutherford backscattering technique and measured the energy loss of elastically scattered He-4 ions from films of cadmium sulfide sputtered on carbon substrates. The experimental data are compared with recent experimental and theoretical results.
NASA Astrophysics Data System (ADS)
Rieger, G.; Pinnington, E. H.; Ciubotariu, C.
2000-12-01
Absolute photon emission cross sections following electron capture reactions have been measured for C2+, N3+, N4+ and O3+ ions colliding with Li(2s) atoms at keV energies. The results are compared with calculations using the extended classical over-the-barrier model by Niehaus. We explore the limits of our experimental method and present a detailed discussion of experimental errors.
Single event upset suspectibility testing of the Xilinx Virtex II FPGA
NASA Technical Reports Server (NTRS)
Carmichael, C.; Swift, C.; Yui, G.
2002-01-01
Heavy ion testing of the Xilinx Virtex II was conducted on the configuration, block RAM and user flip flop cells to determine their static single-event upset susceptibility using LETs of 1.2 to 60 MeVcm^2/mg. A software program specifically designed to count errors in the FPGA was used to reveal L1/e, values (the LET at which the cross section is l/e times the saturation cross-section) and single-event functional-interrupt failures.
Measurement of keV-neutron capture cross sections and capture gamma-ray spectra of Cs-133 and I-127
NASA Astrophysics Data System (ADS)
Umezawa, Seigo; Igashira, Masayuki; Katabuchi, Tatuya; Dominic, Moraru; Yanagida, Shotaro; Okamiya, Tomohiro
2017-09-01
The neutron capture cross sections and the capture gamma-ray spectra of 127I and 133Cs at incident neutron energies from 15 to 100 keV have been measured by the time-of-flight method. Capture gamma-rays were detected with an anti-Compton NaI(Tl) spectrometer, and the pulse-height weighting technique was applied to derive capture yields. The capture cross sections of 127I and 133Cs were determined using the standard capture cross section of 197Au. The total errors of the cross sections were 3.8-5.1%. The obtained cross sections were compared with evaluated values in JENDL-4.0 and ENDF/B-VII.1. For 127I, the energy dependence is different between the present results and the evaluations. For 133Cs, the evaluated values in JENDL-4.0 agree with the present results but the evaluated values in ENDF/B-VII.1 are smaller than the present results by 14%-18%. The capture gamma-ray spectra of 133Cs and 127I were derived by unfolding the pulse height spectra with detector response functions.
Panesar, Sukhmeet S; Netuveli, Gopalakrishnan; Carson-Stevens, Andrew; Javad, Sundas; Patel, Bhavesh; Parry, Gareth; Donaldson, Liam J; Sheikh, Aziz
2013-11-21
The Orthopaedic Error Index for hospitals aims to provide the first national assessment of the relative safety of provision of orthopaedic surgery. Cross-sectional study (retrospective analysis of records in a database). The National Reporting and Learning System is the largest national repository of patient-safety incidents in the world with over eight million error reports. It offers a unique opportunity to develop novel approaches to enhancing patient safety, including investigating the relative safety of different healthcare providers and specialties. We extracted all orthopaedic error reports from the system over 1 year (2009-2010). The Orthopaedic Error Index was calculated as a sum of the error propensity and severity. All relevant hospitals offering orthopaedic surgery in England were then ranked by this metric to identify possible outliers that warrant further attention. 155 hospitals reported 48 971 orthopaedic-related patient-safety incidents. The mean Orthopaedic Error Index was 7.09/year (SD 2.72); five hospitals were identified as outliers. Three of these units were specialist tertiary hospitals carrying out complex surgery; the remaining two outlier hospitals had unusually high Orthopaedic Error Indexes: mean 14.46 (SD 0.29) and 15.29 (SD 0.51), respectively. The Orthopaedic Error Index has enabled identification of hospitals that may be putting patients at disproportionate risk of orthopaedic-related iatrogenic harm and which therefore warrant further investigation. It provides the prototype of a summary index of harm to enable surveillance of unsafe care over time across institutions. Further validation and scrutiny of the method will be required to assess its potential to be extended to other hospital specialties in the UK and also internationally to other health systems that have comparable national databases of patient-safety incidents.
Three-dimensional modeling of the cochlea by use of an arc fitting approach.
Schurzig, Daniel; Lexow, G Jakob; Majdani, Omid; Lenarz, Thomas; Rau, Thomas S
2016-12-01
A cochlea modeling approach is presented allowing for a user defined degree of geometry simplification which automatically adjusts to the patient specific anatomy. Model generation can be performed in a straightforward manner due to error estimation prior to the actual generation, thus minimizing modeling time. Therefore, the presented technique is well suited for a wide range of applications including finite element analyses where geometrical simplifications are often inevitable. The method is presented for n=5 cochleae which were segmented using a custom software for increased accuracy. The linear basilar membrane cross sections are expanded to areas while the scalae contours are reconstructed by a predefined number of arc segments. Prior to model generation, geometrical errors are evaluated locally for each cross section as well as globally for the resulting models and their basal turn profiles. The final combination of all reconditioned features to a 3D volume is performed in Autodesk Inventor using the loft feature. Due to the volume generation based on cubic splines, low errors could be achieved even for low numbers of arc segments and provided cross sections, both of which correspond to a strong degree of model simplification. Model generation could be performed in a time efficient manner. The proposed simplification method was proven to be well suited for the helical cochlea geometry. The generated output data can be imported into commercial software tools for various analyses representing a time efficient way to create cochlea models optimally suited for the desired task.
Ranking and validation of spallation models for isotopic production cross sections of heavy residua
NASA Astrophysics Data System (ADS)
Sharma, Sushil K.; Kamys, Bogusław; Goldenbaum, Frank; Filges, Detlef
2017-07-01
The production cross sections of isotopically identified residual nuclei of spallation reactions induced by 136Xe projectiles at 500AMeV on hydrogen target were analyzed in a two-step model. The first stage of the reaction was described by the INCL4.6 model of an intranuclear cascade of nucleon-nucleon and pion-nucleon collisions whereas the second stage was analyzed by means of four different models; ABLA07, GEM2, GEMINI++ and SMM. The quality of the data description was judged quantitatively using two statistical deviation factors; the H-factor and the M-factor. It was found that the present analysis leads to a different ranking of models as compared to that obtained from the qualitative inspection of the data reproduction. The disagreement was caused by sensitivity of the deviation factors to large statistical errors present in some of the data. A new deviation factor, the A factor, was proposed, that is not sensitive to the statistical errors of the cross sections. The quantitative ranking of models performed using the A-factor agreed well with the qualitative analysis of the data. It was concluded that using the deviation factors weighted by statistical errors may lead to erroneous conclusions in the case when the data cover a large range of values. The quality of data reproduction by the theoretical models is discussed. Some systematic deviations of the theoretical predictions from the experimental results are observed.
Estimation of uncertainty for contour method residual stress measurements
Olson, Mitchell D.; DeWald, Adrian T.; Prime, Michael B.; ...
2014-12-03
This paper describes a methodology for the estimation of measurement uncertainty for the contour method, where the contour method is an experimental technique for measuring a two-dimensional map of residual stress over a plane. Random error sources including the error arising from noise in displacement measurements and the smoothing of the displacement surfaces are accounted for in the uncertainty analysis. The output is a two-dimensional, spatially varying uncertainty estimate such that every point on the cross-section where residual stress is determined has a corresponding uncertainty value. Both numerical and physical experiments are reported, which are used to support the usefulnessmore » of the proposed uncertainty estimator. The uncertainty estimator shows the contour method to have larger uncertainty near the perimeter of the measurement plane. For the experiments, which were performed on a quenched aluminum bar with a cross section of 51 × 76 mm, the estimated uncertainty was approximately 5 MPa (σ/E = 7 · 10⁻⁵) over the majority of the cross-section, with localized areas of higher uncertainty, up to 10 MPa (σ/E = 14 · 10⁻⁵).« less
Matching factorization theorems with an inverse-error weighting
NASA Astrophysics Data System (ADS)
Echevarria, Miguel G.; Kasemets, Tomas; Lansberg, Jean-Philippe; Pisano, Cristian; Signori, Andrea
2018-06-01
We propose a new fast method to match factorization theorems applicable in different kinematical regions, such as the transverse-momentum-dependent and the collinear factorization theorems in Quantum Chromodynamics. At variance with well-known approaches relying on their simple addition and subsequent subtraction of double-counted contributions, ours simply builds on their weighting using the theory uncertainties deduced from the factorization theorems themselves. This allows us to estimate the unknown complete matched cross section from an inverse-error-weighted average. The method is simple and provides an evaluation of the theoretical uncertainty of the matched cross section associated with the uncertainties from the power corrections to the factorization theorems (additional uncertainties, such as the nonperturbative ones, should be added for a proper comparison with experimental data). Its usage is illustrated with several basic examples, such as Z boson, W boson, H0 boson and Drell-Yan lepton-pair production in hadronic collisions, and compared to the state-of-the-art Collins-Soper-Sterman subtraction scheme. It is also not limited to the transverse-momentum spectrum, and can straightforwardly be extended to match any (un)polarized cross section differential in other variables, including multi-differential measurements.
Testing of the ABBN-RF multigroup data library in photon transport calculations
NASA Astrophysics Data System (ADS)
Koscheev, Vladimir; Lomakov, Gleb; Manturov, Gennady; Tsiboulia, Anatoly
2017-09-01
Gamma radiation is produced via both of nuclear fuel and shield materials. Photon interaction is known with appropriate accuracy, but secondary gamma ray production known much less. The purpose of this work is studying secondary gamma ray production data from neutron induced reactions in iron and lead by using MCNP code and modern nuclear data as ROSFOND, ENDF/B-7.1, JEFF-3.2 and JENDL-4.0. Results of calculations show that all of these nuclear data have different photon production data from neutron induced reactions and have poor agreement with evaluated benchmark experiment. The ABBN-RF multigroup cross-section library is based on the ROSFOND data. It presented in two forms of micro cross sections: ABBN and MATXS formats. Comparison of group-wise calculations using both ABBN and MATXS data to point-wise calculations with the ROSFOND library shows a good agreement. The discrepancies between calculation and experimental C/E results in neutron spectra are in the limit of experimental errors. For the photon spectrum they are out of experimental errors. Results of calculations using group-wise and point-wise representation of cross sections show a good agreement both for photon and neutron spectra.
Matching factorization theorems with an inverse-error weighting
Echevarria, Miguel G.; Kasemets, Tomas; Lansberg, Jean-Philippe; ...
2018-04-03
We propose a new fast method to match factorization theorems applicable in different kinematical regions, such as the transverse-momentum-dependent and the collinear factorization theorems in Quantum Chromodynamics. At variance with well-known approaches relying on their simple addition and subsequent subtraction of double-counted contributions, ours simply builds on their weighting using the theory uncertainties deduced from the factorization theorems themselves. This allows us to estimate the unknown complete matched cross section from an inverse-error-weighted average. The method is simple and provides an evaluation of the theoretical uncertainty of the matched cross section associated with the uncertainties from the power corrections tomore » the factorization theorems (additional uncertainties, such as the nonperturbative ones, should be added for a proper comparison with experimental data). Its usage is illustrated with several basic examples, such as Z boson, W boson, H 0 boson and Drell–Yan lepton-pair production in hadronic collisions, and compared to the state-of-the-art Collins–Soper–Sterman subtraction scheme. In conclusion, it is also not limited to the transverse-momentum spectrum, and can straightforwardly be extended to match any (un)polarized cross section differential in other variables, including multi-differential measurements.« less
Matching factorization theorems with an inverse-error weighting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Echevarria, Miguel G.; Kasemets, Tomas; Lansberg, Jean-Philippe
We propose a new fast method to match factorization theorems applicable in different kinematical regions, such as the transverse-momentum-dependent and the collinear factorization theorems in Quantum Chromodynamics. At variance with well-known approaches relying on their simple addition and subsequent subtraction of double-counted contributions, ours simply builds on their weighting using the theory uncertainties deduced from the factorization theorems themselves. This allows us to estimate the unknown complete matched cross section from an inverse-error-weighted average. The method is simple and provides an evaluation of the theoretical uncertainty of the matched cross section associated with the uncertainties from the power corrections tomore » the factorization theorems (additional uncertainties, such as the nonperturbative ones, should be added for a proper comparison with experimental data). Its usage is illustrated with several basic examples, such as Z boson, W boson, H 0 boson and Drell–Yan lepton-pair production in hadronic collisions, and compared to the state-of-the-art Collins–Soper–Sterman subtraction scheme. In conclusion, it is also not limited to the transverse-momentum spectrum, and can straightforwardly be extended to match any (un)polarized cross section differential in other variables, including multi-differential measurements.« less
A time projection chamber for high accuracy and precision fission cross-section measurements
Heffner, M.; Asner, D. M.; Baker, R. G.; ...
2014-05-22
The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross-section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4π acceptance for fission fragments and complete charged particle track reconstruction are powerful features of the fissionTPC which will be used to measure fission cross-sections and examine the associated systematic errors. This study provides a detailed description of the design requirements, the design solutions, and the initial performance ofmore » the fissionTPC.« less
Measurement of the Total Cross Section of Uranium-Uranium Collisions at √{sNN} = 192 . 8 GeV
NASA Astrophysics Data System (ADS)
Baltz, A. J.; Fischer, W.; Blaskiewicz, M.; Gassner, D.; Drees, K. A.; Luo, Y.; Minty, M.; Thieberger, P.; Wilinski, M.; Pshenichnov, I. A.
2014-03-01
The total cross section of Uranium-Uranium at √{sNN} = 192 . 8 GeV has been measured to be 515 +/-13stat +/-22sys barn, which agrees with the calculated theoretical value of 487.3 barn within experimental error. That this total cross section is more than an order of magnitude larger than the geometric ion-ion cross section is primarily due to Bound-Free Pair Production (BFPP) and Electro-Magnetic Dissociation (EMD). Nearly all beam losses were due to geometric, BFPP and EMD collisions. This allowed the determination of the total cross section from the measured beam loss rates and luminosity. The beam loss rate is calculated from a time-dependent measurement of the total beam intensity. The luminosity is measured via the detection of neutron pairs in time-coincidence in the Zero Degree Calorimeters. Apart from a general interest in verifying the calculations experimentally, an accurate prediction of the losses created in the heavy ion collisions is of practical interest for the LHC, where collision products have the potential to quench cryogenically cooled magnets.
ERIC Educational Resources Information Center
Leicher, Veronika; Mulder, Regina H.
2016-01-01
Purpose: The purpose of this replication study is to identify relevant individual and contextual factors influencing learning from errors at work and to determine if the predictors for learning activities are the same for the domains of nursing and retail banking. Design/methodology/approach: A cross-sectional replication study was carried out in…
Automated Cross-Sectional Measurement Method of Intracranial Dural Venous Sinuses.
Lublinsky, S; Friedman, A; Kesler, A; Zur, D; Anconina, R; Shelef, I
2016-03-01
MRV is an important blood vessel imaging and diagnostic tool for the evaluation of stenosis, occlusions, or aneurysms. However, an accurate image-processing tool for vessel comparison is unavailable. The purpose of this study was to develop and test an automated technique for vessel cross-sectional analysis. An algorithm for vessel cross-sectional analysis was developed that included 7 main steps: 1) image registration, 2) masking, 3) segmentation, 4) skeletonization, 5) cross-sectional planes, 6) clustering, and 7) cross-sectional analysis. Phantom models were used to validate the technique. The method was also tested on a control subject and a patient with idiopathic intracranial hypertension (4 large sinuses tested: right and left transverse sinuses, superior sagittal sinus, and straight sinus). The cross-sectional area and shape measurements were evaluated before and after lumbar puncture in patients with idiopathic intracranial hypertension. The vessel-analysis algorithm had a high degree of stability with <3% of cross-sections manually corrected. All investigated principal cranial blood sinuses had a significant cross-sectional area increase after lumbar puncture (P ≤ .05). The average triangularity of the transverse sinuses was increased, and the mean circularity of the sinuses was decreased by 6% ± 12% after lumbar puncture. Comparison of phantom and real data showed that all computed errors were <1 voxel unit, which confirmed that the method provided a very accurate solution. In this article, we present a novel automated imaging method for cross-sectional vessels analysis. The method can provide an efficient quantitative detection of abnormalities in the dural sinuses. © 2016 by American Journal of Neuroradiology.
Sions, Jaclyn Megan; Smith, Andrew Craig; Hicks, Gregory Evan; Elliott, James Matthew
2016-08-01
To evaluate intra- and inter-examiner reliability for the assessment of relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area, i.e., total cross-sectional area minus intramuscular fat, from T1-weighted magnetic resonance images obtained in older adults with chronic low back pain. Reliability study. n = 13 (69.3 ± 8.2 years old) After lumbar magnetic resonance imaging, two examiners produced relative cross-sectional area measurements of multifidi, erector spinae, psoas, and quadratus lumborum by tracing regions of interest just inside fascial borders. Pixel-intensity summaries were used to determine muscle-to-fat infiltration indices; relative muscle cross-sectional area was calculated. Intraclass correlation coefficients were used to estimate intra- and inter-examiner reliability; standard error of measurement was calculated. Intra-examiner intraclass correlation coefficient point estimates for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area were excellent for multifidi and erector spinae across levels L2-L5 (ICC = 0.77-0.99). At L3, intra-examiner reliability was excellent for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area for both psoas and quadratus lumborum (ICC = 0.81-0.99). Inter-examiner intraclass correlation coefficients ranged from poor to excellent for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area. Assessment of relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area in older adults with chronic low back pain can be reliably determined by one examiner from T1-weighted images. Such assessments provide valuable information, as muscle-to-fat infiltration indices and relative muscle cross-sectional area indicate that a substantial amount of relative cross-sectional area may be magnetic resonance-visible intramuscular fat in older adults with chronic low back pain. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Kuo, Ching Yi; Pan, Chin
2010-09-01
This study experimentally investigates steam condensation in rectangular microchannels with uniform and converging cross-sections and a mean hydraulic diameter of 135 µm. The steam flow in the microchannels was cooled by water cross-flowing along its bottom surface, which is different from other methods reported in the literature. The flow patterns, two-phase flow pressure drop and condensation heat transfer coefficient are determined. The microchannels with the uniform cross-section design have a higher heat transfer coefficient than those with the converging cross-section under condensation in the mist/annular flow regimes, although the latter work best for draining two-phase fluids composed of uncondensed steam and liquid water, which is consistent with the result of our previous study. From the experimental results, dimensionless correlations of condensation heat transfer for the mist and annular flow regions and a two-phase frictional multiplier are developed for the microchannels with both types of cross-section designs. The experimental data agree well with the obtained correlations, with the maximum mean absolute errors of 6.4% for the two-phase frictional multiplier and 6.0% for the condensation heat transfer.
Syntactic and semantic errors in radiology reports associated with speech recognition software.
Ringler, Michael D; Goss, Brian C; Bartholmai, Brian J
2017-03-01
Speech recognition software can increase the frequency of errors in radiology reports, which may affect patient care. We retrieved 213,977 speech recognition software-generated reports from 147 different radiologists and proofread them for errors. Errors were classified as "material" if they were believed to alter interpretation of the report. "Immaterial" errors were subclassified as intrusion/omission or spelling errors. The proportion of errors and error type were compared among individual radiologists, imaging subspecialty, and time periods. In all, 20,759 reports (9.7%) contained errors, of which 3992 (1.9%) were material errors. Among immaterial errors, spelling errors were more common than intrusion/omission errors ( p < .001). Proportion of errors and fraction of material errors varied significantly among radiologists and between imaging subspecialties ( p < .001). Errors were more common in cross-sectional reports, reports reinterpreting results of outside examinations, and procedural studies (all p < .001). Error rate decreased over time ( p < .001), which suggests that a quality control program with regular feedback may reduce errors.
Remote sensing of channels and riparian zones with a narrow-beam aquatic-terrestrial LIDAR
Jim McKean; Dave Nagel; Daniele Tonina; Philip Bailey; Charles Wayne Wright; Carolyn Bohn; Amar Nayegandhi
2009-01-01
The high-resolution Experimental Advanced Airborne Research LIDAR (EAARL) is a new technology for cross-environment surveys of channels and floodplains. EAARL measurements of basic channel geometry, such as wetted cross-sectional area, are within a few percent of those from control field surveys. The largest channel mapping errors are along stream banks. The LIDAR data...
Hegvik, Tor-Arne; Instanes, Johanne Telnes; Haavik, Jan; Klungsøyr, Kari; Engeland, Anders
2018-05-01
The article "Associations between attention-deficit/hyperactivity disorder and autoimmune diseases are modified by sex: a population-based cross-sectional study", written by Tor-Arne Hegvik, Johanne Telnes Instanes, Jan Haavik, Kari Klungsøyr and Anders Engeland, was originally published electronically on the publisher's internet portal (currently SpringerLink) on October 5, 2017 without open access due to an error by the Springer editorial office in the processing of this article. The authors had originally opted for open access.
Low-Energy Proton Testing Methodology
NASA Technical Reports Server (NTRS)
Pellish, Jonathan A.; Marshall, Paul W.; Heidel, David F.; Schwank, James R.; Shaneyfelt, Marty R.; Xapsos, M.A.; Ladbury, Raymond L.; LaBel, Kenneth A.; Berg, Melanie; Kim, Hak S.;
2009-01-01
Use of low-energy protons and high-energy light ions is becoming necessary to investigate current-generation SEU thresholds. Systematic errors can dominate measurements made with low-energy protons. Range and energy straggling contribute to systematic error. Low-energy proton testing is not a step-and-repeat process. Low-energy protons and high-energy light ions can be used to measure SEU cross section of single sensitive features; important for simulation.
Aad, G.; Abbott, B.; Abdallah, J.; ...
2014-10-28
In this study, a measurement of the totalmore » $pp$ cross section at the LHC at $$\\sqrt{s}=7$$ TeV is presented. In a special run with high-$$\\beta^{\\star}$$ beam optics, an integrated luminosity of 80 µb -1 was accumulated in order to measure the differential elastic cross section as a function of the Mandelstam momentum transfer variable $t$. The measurement is performed with the ALFA sub-detector of ATLAS. Using a fit to the differential elastic cross section in the |t| range from 0.01 GeV 2 to 0.1 GeV 2 to extrapolate to |t| → 0, the total cross section, σ tot($pp$ → X), is measured via the optical theorem to be: σ tot($pp$ → X) = 95.35 ± 0.38 (stat.) ± 1.25 (exp.) ± 0.37 (extr.) mb, where the first error is statistical, the second accounts for all experimental systematic uncertainties and the last is related to uncertainties in the extrapolation to |t| → 0. In addition, the slope of the elastic cross section at small |t| is determined to be B = 19.73 ± 0.14 (stat.) ± 0.26 (syst.) GeV -2.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aad, G.; Abbott, B.; Abdallah, J.
In this study, a measurement of the totalmore » $pp$ cross section at the LHC at $$\\sqrt{s}=7$$ TeV is presented. In a special run with high-$$\\beta^{\\star}$$ beam optics, an integrated luminosity of 80 µb -1 was accumulated in order to measure the differential elastic cross section as a function of the Mandelstam momentum transfer variable $t$. The measurement is performed with the ALFA sub-detector of ATLAS. Using a fit to the differential elastic cross section in the |t| range from 0.01 GeV 2 to 0.1 GeV 2 to extrapolate to |t| → 0, the total cross section, σ tot($pp$ → X), is measured via the optical theorem to be: σ tot($pp$ → X) = 95.35 ± 0.38 (stat.) ± 1.25 (exp.) ± 0.37 (extr.) mb, where the first error is statistical, the second accounts for all experimental systematic uncertainties and the last is related to uncertainties in the extrapolation to |t| → 0. In addition, the slope of the elastic cross section at small |t| is determined to be B = 19.73 ± 0.14 (stat.) ± 0.26 (syst.) GeV -2.« less
Error analysis and prevention of cosmic ion-induced soft errors in static CMOS RAMs
NASA Astrophysics Data System (ADS)
Diehl, S. E.; Ochoa, A., Jr.; Dressendorfer, P. V.; Koga, P.; Kolasinski, W. A.
1982-12-01
Cosmic ray interactions with memory cells are known to cause temporary, random, bit errors in some designs. The sensitivity of polysilicon gate CMOS static RAM designs to logic upset by impinging ions has been studied using computer simulations and experimental heavy ion bombardment. Results of the simulations are confirmed by experimental upset cross-section data. Analytical models have been extended to determine and evaluate design modifications which reduce memory cell sensitivity to cosmic ions. A simple design modification, the addition of decoupling resistance in the feedback path, is shown to produce static RAMs immune to cosmic ray-induced bit errors.
Pomeroy, Emma; Macintosh, Alison; Wells, Jonathan C K; Cole, Tim J; Stock, Jay T
2018-05-01
Estimating body mass from skeletal dimensions is widely practiced, but methods for estimating its components (lean and fat mass) are poorly developed. The ability to estimate these characteristics would offer new insights into the evolution of body composition and its variation relative to past and present health. This study investigates the potential of long bone cross-sectional properties as predictors of body, lean, and fat mass. Humerus, femur and tibia midshaft cross-sectional properties were measured by peripheral quantitative computed tomography in sample of young adult women (n = 105) characterized by a range of activity levels. Body composition was estimated from bioimpedance analysis. Lean mass correlated most strongly with both upper and lower limb bone properties (r values up to 0.74), while fat mass showed weak correlations (r ≤ 0.29). Estimation equations generated from tibial midshaft properties indicated that lean mass could be estimated relatively reliably, with some improvement using logged data and including bone length in the models (minimum standard error of estimate = 8.9%). Body mass prediction was less reliable and fat mass only poorly predicted (standard errors of estimate ≥11.9% and >33%, respectively). Lean mass can be predicted more reliably than body mass from limb bone cross-sectional properties. The results highlight the potential for studying evolutionary trends in lean mass from skeletal remains, and have implications for understanding the relationship between bone morphology and body mass or composition. © 2018 The Authors. American Journal of Physical Anthropology Published by Wiley Periodicals, Inc.
Liljegren, Mats; Ekberg, Kerstin
2009-01-01
The aim of the present study was to examine the cross-sectional and 2-year longitudinal associations between perceived organizational justice, self-rated health and burnout. The study used questionnaire data from 428 Swedish employment officers and the data was analyzed with Structural Equation Modeling, SEM. Two different models were tested: a global organizational justice model (with and without correlated measurement errors) and a differentiated (distributive, procedural and interactional organizational justice) justice model (with and without correlated measurement errors). The global justice model with autocorrelations had the most satisfactory goodness-of-fit indices. Global justice showed statistically significant (p < 0.01) cross-sectional (0.80 {mle 0.84) and longitudinal positive associations (0.76 mle 0.82) between organizational justice and self-rated health, and significant (p < 0.01) negative associations between organizational justice and burnout (cross-sectional: mle = -0.85, longitudinal -0.83 mle -0.84). The global justice construct showed better goodness-of-fit indices than the threefold justice construct but a differentiated organizational justice concept could give valuable information about health related risk factors: if they are structural (distributive justice), procedural (procedural justice) or inter-personal (interactional justice). The two approaches to study organizational justice should therefore be regarded as complementary rather than exclusive.
Cross section measurements of radiative KL2,3 RRS in 24Cr and L3M4,5 RRS in 59Pr for Mn Kα1,2 X-rays
NASA Astrophysics Data System (ADS)
Sharma, Veena; Upmanyu, Arun; Singh, Ranjit; Singh, Gurjot; Sharma, Hitesh; Kumar, Sanjeev; Mehta, D.
2017-06-01
The KL2,3 and L3M4,5 radiative resonant Raman scattering (RRS) cross sections have been measured for the quasimonochromatic Mn Kα1,2 X-rays (5.895 keV) in 24Cr (K-shell level width (ΓK) =1.08 eV) and 59 Pr (L3-subshell level width (ΓL3) =3.60 eV), respectively, using targets in metallic and various chemical forms. The incident Mn Kα1,2 X-ray energy is lower than the K-shell binding energy of 24Cr and L3-subshell binding energy of 59Pr by 94 ΓK (Cr) and 94 ΓL3 (Pr), respectively. The experimental measurements were performed with a low energy Ge detector (LEGe) and a radioactive 55Fe annular source in conjunction with 24Cr absorber. The measured cross section values for the 24Cr and 59 Pr elements in their various oxidation states are found to be same within experimental errors. The measurements were further extended to investigate alignment of the intermediate L3-subshell (J =3/2) virtual vacancy states in 59Pr through angular distribution measurements for RRS photon emission, which is found to be isotropic within experimental errors.
Error, stress, and teamwork in medicine and aviation: cross sectional surveys
NASA Technical Reports Server (NTRS)
Sexton, J. B.; Thomas, E. J.; Helmreich, R. L.
2000-01-01
OBJECTIVES: To survey operating theatre and intensive care unit staff about attitudes concerning error, stress, and teamwork and to compare these attitudes with those of airline cockpit crew. DESIGN:: Cross sectional surveys. SETTING:: Urban teaching and non-teaching hospitals in the United States, Israel, Germany, Switzerland, and Italy. Major airlines around the world. PARTICIPANTS:: 1033 doctors, nurses, fellows, and residents working in operating theatres and intensive care units and over 30 000 cockpit crew members (captains, first officers, and second officers). MAIN OUTCOME MEASURES:: Perceptions of error, stress, and teamwork. RESULTS:: Pilots were least likely to deny the effects of fatigue on performance (26% v 70% of consultant surgeons and 47% of consultant anaesthetists). Most pilots (97%) and intensive care staff (94%) rejected steep hierarchies (in which senior team members are not open to input from junior members), but only 55% of consultant surgeons rejected such hierarchies. High levels of teamwork with consultant surgeons were reported by 73% of surgical residents, 64% of consultant surgeons, 39% of anaesthesia consultants, 28% of surgical nurses, 25% of anaesthetic nurses, and 10% of anaesthetic residents. Only a third of staff reported that errors are handled appropriately at their hospital. A third of intensive care staff did not acknowledge that they make errors. Over half of intensive care staff reported that they find it difficult to discuss mistakes. CONCLUSIONS: Medical staff reported that error is important but difficult to discuss and not handled well in their hospital. Barriers to discussing error are more important since medical staff seem to deny the effect of stress and fatigue on performance. Further problems include differing perceptions of teamwork among team members and reluctance of senior theatre staff to accept input from junior members.
Error, stress, and teamwork in medicine and aviation: cross sectional surveys
Sexton, J Bryan; Thomas, Eric J; Helmreich, Robert L
2000-01-01
Objectives: To survey operating theatre and intensive care unit staff about attitudes concerning error, stress, and teamwork and to compare these attitudes with those of airline cockpit crew. Design: Cross sectional surveys. Setting: Urban teaching and non-teaching hospitals in the United States, Israel, Germany, Switzerland, and Italy. Major airlines around the world. Participants: 1033 doctors, nurses, fellows, and residents working in operating theatres and intensive care units and over 30 000 cockpit crew members (captains, first officers, and second officers). Main outcome measures: Perceptions of error, stress, and teamwork. Results: Pilots were least likely to deny the effects of fatigue on performance (26% v 70% of consultant surgeons and 47% of consultant anaesthetists). Most pilots (97%) and intensive care staff (94%) rejected steep hierarchies (in which senior team members are not open to input from junior members), but only 55% of consultant surgeons rejected such hierarchies. High levels of teamwork with consultant surgeons were reported by 73% of surgical residents, 64% of consultant surgeons, 39% of anaesthesia consultants, 28% of surgical nurses, 25% of anaesthetic nurses, and 10% of anaesthetic residents. Only a third of staff reported that errors are handled appropriately at their hospital. A third of intensive care staff did not acknowledge that they make errors. Over half of intensive care staff reported that they find it difficult to discuss mistakes. Conclusions: Medical staff reported that error is important but difficult to discuss and not handled well in their hospital. Barriers to discussing error are more important since medical staff seem to deny the effect of stress and fatigue on performance. Further problems include differing perceptions of teamwork among team members and reluctance of senior theatre staff to accept input from junior members. PMID:10720356
Full temperature single event upset characterization of two microprocessor technologies
NASA Technical Reports Server (NTRS)
Nichols, Donald K.; Coss, James R.; Smith, L. S.; Rax, Bernard; Huebner, Mark
1988-01-01
Data for the 9450 I3L bipolar microprocessor and the 80C86 CMOS/epi (vintage 1985) microprocessor are presented, showing single-event soft errors for the full MIL-SPEC temperature range of -55 to 125 C. These data show for the first time that the soft-error cross sections continue to decrease with decreasing temperature at subzero temperatures. The temperature dependence of the two parts, however, is very different.
NASA Astrophysics Data System (ADS)
Ducru, Pablo; Josey, Colin; Dibert, Karia; Sobes, Vladimir; Forget, Benoit; Smith, Kord
2017-04-01
This article establishes a new family of methods to perform temperature interpolation of nuclear interactions cross sections, reaction rates, or cross sections times the energy. One of these quantities at temperature T is approximated as a linear combination of quantities at reference temperatures (Tj). The problem is formalized in a cross section independent fashion by considering the kernels of the different operators that convert cross section related quantities from a temperature T0 to a higher temperature T - namely the Doppler broadening operation. Doppler broadening interpolation of nuclear cross sections is thus here performed by reconstructing the kernel of the operation at a given temperature T by means of linear combination of kernels at reference temperatures (Tj). The choice of the L2 metric yields optimal linear interpolation coefficients in the form of the solutions of a linear algebraic system inversion. The optimization of the choice of reference temperatures (Tj) is then undertaken so as to best reconstruct, in the L∞ sense, the kernels over a given temperature range [Tmin ,Tmax ]. The performance of these kernel reconstruction methods is then assessed in light of previous temperature interpolation methods by testing them upon isotope 238U. Temperature-optimized free Doppler kernel reconstruction significantly outperforms all previous interpolation-based methods, achieving 0.1% relative error on temperature interpolation of 238U total cross section over the temperature range [ 300 K , 3000 K ] with only 9 reference temperatures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eloranta, Edwin
The goal of this research has been to improve measurements of snowfall using a combination of millimeter-wavelength radar and High Spectral Resolution Lidar (HSRL) Observations. Snowflakes are large compared to the 532nm HSRL wavelength and small compared to the 3.2 and 8.6 mm wavelength radars used in this study. This places the particles in the optical scattering regime of the HSRL, where extinction cross-section is proportional to the projected area of the particles, and in the Rayleigh regime for the radar, where the backscatter cross-section is proportional to the mass-squared of the particles. Forming a ratio of the radar measuredmore » cross-section to the HSRL measured cross section eliminates any dependence on the number of scattering particles, yielding a quantity proportional to the average mass-squared of the snowflakes over the average area of the flakes. Using simultaneous radar measurements of particle fall velocities, which are dependent particle mass and cross-sectional area it is possible to derive the average mass of the snow flakes, and with the radar measured fall velocities compute the snowfall rate. Since this retrieval requires the optical extinction cross-section we began by considering errors this quantity. The HSRL is particularly good at measuring the backscatter cross-section. In previous studies of snowfall in the high Arctic were able to estimate the extinction cross-section directly as a fixed ratio to the backscatter cross-section. Measurements acquired in the STORMVEX experiment in Colorado showed that this approach was not valid in mid-latitude snowfalls and that direct measurement of the extinction cross-section is required. Attempts to measure the extinction directly uncovered shortcomings in thermal regulation and mechanical stability of the newly deployed DOE HSRL systems. These problems were largely mitigated by modifications installed in both of the DOE systems. We also investigated other sources of error in the HSRL direct measurement of extinction (see appendix II of this report). We also developed improved algorithms to extract extinction from the HSRL data. These have been installed in the standard HSRL data processing software and are now available to all users of HSRL data. Validation of snowfall measurements has proven difficult due to the unreliability of conventional snowfall measurements coupled with the complexity of considering the vast variety of snowflake geometries. It was difficult to tell how well the algorithm’s approach to accommodating differences in snowflakes was working without good measurements for comparison. As a result, we decided to apply this approach to the somewhat simpler, but scientifically important, problem of drizzle measurement. Here the particle shape is known and the conventional measurement are more reliable. These algorithms where successfully applied to drizzle data acquired during the ARM MAGIC study of marine stratus clouds between California and Hawaii (see Appendix I). This technique is likely to become a powerful tool for studying lifetime of the climatically important marine stratus clouds.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aaboud, M.; Aad, G.; Abbott, B.
A measurement of the total ppcross section at the LHC at √s=8TeV is presented. An integrated luminosity of 500 μb-1 was accumulated in a special run with high-β beam optics to measure the differential elastic cross section as a function of the Mandelstam momentum transfer variable t. The measurement is performed with the ALFA sub-detector of ATLAS. Using a fit to the differential elastic cross section in the -t range from 0.014GeV2 to 0.1GeV2 to extrapolate t→0, the total cross section, σtot(pp →X), is measured via the optical theorem to be σtot(pp→ X) = 96.07±0.18 (stat.)±0.85 (exp.)± 0.31 (extr.) mb,more » where the first error is statistical, the second accounts for all experimental systematic uncertainties and the last is related to uncertainties in the extrapolation t→0. In addition, the slope of the exponential function describing the elastic cross section at small t is determined to be B =19.74 ±0.05 (stat.) ±0.23 (syst.) GeV-2.« less
Takamiya, K; Imanaka, T; Egbert, S D; Rühm, W
2011-05-01
In a previous paper, Takamiya et al. calculated (63)Ni production in copper samples exposed to the Hiroshima atomic bomb. More specifically, they used their experimental cross-section values of the (63)Cu(n,p)(63)Ni reaction and compared the result with that of the corresponding calculation in the radiation dosimetry system DS02, which used another set of cross-section values. These results were different, and the following two reasons were found: typographical errors in several energy boundary values in the DS02 report that was also used in the calculation by Takamiya et al. and an inappropriate assumption on the cross-section values of the low neutron energy region in the calculation by Takamiya et al. These two issues are described and amended in the present report.
NASA Astrophysics Data System (ADS)
Wilson, M. D.; Durand, M.; Jung, H. C.; Alsdorf, D.
2015-04-01
The Surface Water and Ocean Topography (SWOT) mission, scheduled for launch in 2020, will provide a step-change improvement in the measurement of terrestrial surface-water storage and dynamics. In particular, it will provide the first, routine two-dimensional measurements of water-surface elevations. In this paper, we aimed to (i) characterise and illustrate in two dimensions the errors which may be found in SWOT swath measurements of terrestrial surface water, (ii) simulate the spatio-temporal sampling scheme of SWOT for the Amazon, and (iii) assess the impact of each of these on estimates of water-surface slope and river discharge which may be obtained from SWOT imagery. We based our analysis on a virtual mission for a ~260 km reach of the central Amazon (Solimões) River, using a hydraulic model to provide water-surface elevations according to SWOT spatio-temporal sampling to which errors were added based on a two-dimensional height error spectrum derived from the SWOT design requirements. We thereby obtained water-surface elevation measurements for the Amazon main stem as may be observed by SWOT. Using these measurements, we derived estimates of river slope and discharge and compared them to those obtained directly from the hydraulic model. We found that cross-channel and along-reach averaging of SWOT measurements using reach lengths greater than 4 km for the Solimões and 7.5 km for Purus reduced the effect of systematic height errors, enabling discharge to be reproduced accurately from the water height, assuming known bathymetry and friction. Using cross-sectional averaging and 20 km reach lengths, results show Nash-Sutcliffe model efficiency values of 0.99 for the Solimões and 0.88 for the Purus, with 2.6 and 19.1 % average overall error in discharge, respectively. We extend the results to other rivers worldwide and infer that SWOT-derived discharge estimates may be more accurate for rivers with larger channel widths (permitting a greater level of cross-sectional averaging and the use of shorter reach lengths) and higher water-surface slopes (reducing the proportional impact of slope errors on discharge calculation).
NASA Astrophysics Data System (ADS)
Santra, S.; Mitra, D.; Sarkar, M.; Bhattacharya, D.
2007-10-01
Bremsstrahlung from an X-ray tube was used to excite secondary targets of Ag, Sn, I and Ba to get nearly monochromatic excitation energies of 22.6, 25.8, 29.2 and 32.9 keV, respectively. Th and U were used as targets. The L X-ray fluorescence cross sections of different lines from the targets have been measured. Of the several methods to obtain L subshell photoionisation cross sections from these fluorescence data, the merits and demerits of four common methods have been explained and the method with least uncertainty was suggested as the best one for such analysis. Following this method, with intensities of the resolved Lγ lines, three L subshell photoionisation cross sections have been obtained using six different sets of atomic parameters. The variation of these cross sections with different atomic parameters has been discussed. For σ1, all the derived values are within 30% of one other while for σ2 and σ3, they are within 12%. Measured cross sections have been compared with the data of others and with the theoretical values of Scofield. Finally, the intensity ratios of different L lines have also been compared with available data and the theoretical values. Within experimental errors, our data are in good agreement with the data of others and with the theoretical predictions.
Modeling Systematic Error Effects for a Sensitive Storage Ring EDM Polarimeter
NASA Astrophysics Data System (ADS)
Stephenson, Edward; Imig, Astrid
2009-10-01
The Storage Ring EDM Collaboration has obtained a set of measurements detailing the sensitivity of a storage ring polarimeter for deuterons to small geometrical and rate changes. Various schemes, such as the calculation of the cross ratio [1], can cancel effects due to detector acceptance differences and luminosity differences for states of opposite polarization. Such schemes fail at second-order in the errors, becoming sensitive to geometrical changes, polarization magnitude differences between opposite polarization states, and changes to the detector response with changing data rates. An expansion of the polarimeter response in a Taylor series based on small errors about the polarimeter operating point can parametrize such effects, primarily in terms of the logarithmic derivatives of the cross section and analyzing power. A comparison will be made to measurements obtained with the EDDA detector at COSY-J"ulich. [4pt] [1] G.G. Ohlsen and P.W. Keaton, Jr., NIM 109, 41 (1973).
Obligation towards medical errors disclosure at a tertiary care hospital in Dubai, UAE
Zaghloul, Ashraf Ahmad; Rahman, Syed Azizur; Abou El-Enein, Nagwa Younes
2016-01-01
OBJECTIVE: The study aimed to identify healthcare providers’ obligation towards medical errors disclosure as well as to study the association between the severity of the medical error and the intention to disclose the error to the patients and their families. DESIGN: A cross-sectional study design was followed to identify the magnitude of disclosure among healthcare providers in different departments at a randomly selected tertiary care hospital in Dubai. SETTING AND PARTICIPANTS: The total sample size accounted for 106 respondents. Data were collected using a questionnaire composed of two sections namely; demographic variables of the respondents and a section which included variables relevant to medical error disclosure. RESULTS: Statistical analysis yielded significant association between the obligation to disclose medical errors with male healthcare providers (X2 = 5.1), and being a physician (X2 = 19.3). Obligation towards medical errors disclosure was significantly associated with those healthcare providers who had not committed any medical errors during the past year (X2 = 9.8), and any type of medical error regardless the cause, extent of harm (X2 = 8.7). Variables included in the binary logistic regression model were; status (Exp β (Physician) = 0.39, 95% CI 0.16–0.97), gender (Exp β (Male) = 4.81, 95% CI 1.84–12.54), and medical errors during the last year (Exp β (None) = 2.11, 95% CI 0.6–2.3). CONCLUSION: Education and training of physicians about disclosure conversations needs to start as early as medical school. Like the training in other competencies required of physicians, education in communicating about medical errors could help reduce physicians’ apprehension and make them more comfortable with disclosure conversations. PMID:27567766
Quantifying and predicting interpretational uncertainty in cross-sections
NASA Astrophysics Data System (ADS)
Randle, Charles; Bond, Clare; Monaghan, Alison; Lark, Murray
2015-04-01
Cross-sections are often constructed from data to create a visual impression of the geologist's interpretation of the sub-surface geology. However as with all interpretations, this vision of the sub-surface geology is uncertain. We have designed and carried out an experiment with the aim of quantifying the uncertainty in geological cross-sections created by experts interpreting borehole data. By analysing different attributes of the data and interpretations we reflect on the main controls on uncertainty. A group of ten expert modellers at the British Geological Survey were asked to interpret an 11.4 km long cross-section from south-east Glasgow, UK. The data provided consisted of map and borehole data of the superficial deposits and shallow bedrock. Each modeller had a unique set of 11 boreholes removed from their dataset, to which their interpretations of the top of the bedrock were compared. This methodology allowed quantification of how far from the 'correct answer' each interpretation is at 11 points along each interpreted cross-section line; through comparison of the interpreted and actual bedrock elevations in the boreholes. This resulted in the collection of 110 measurements of the error to use in further analysis. To determine the potential control on uncertainty various attributes relating to the modeller, the interpretation and the data were recorded. Modellers were asked to fill out a questionnaire asking for information; such as how much 3D modelling experience they had, and how long it took them to complete the interpretation. They were also asked to record their confidence in their interpretations graphically, in the form of a confidence level drawn onto the cross-section. Initial analysis showed the majority of the experts' interpreted bedrock elevations within 5 metres of those recorded in the withheld boreholes. Their distribution is peaked and symmetrical about a mean of zero, indicating that there was no tendency for the experts to either under or over estimate the elevation of the bedrock. More complex analysis was completed in the form of linear mixed effects modelling. The modelling was used to determine if there were any correlations between the error and any other parameter recorded in the questionnaire, section or the initial dataset. This has resulted in the determination of both data based and interpreter based controls on uncertainty, adding insight into how uncertainty can be predicted, as well as how interpretation workflows can be improved. Our results will inform further experiments across a wide variety of geological situations to build understanding and best practice workflows for cross-section interpretation to reduce uncertainty.
Legleiter, C.J.; Kinzel, P.J.; Overstreet, B.T.
2011-01-01
This study examined the possibility of mapping depth from optical image data in turbid, sediment-laden channels. Analysis of hyperspectral images from the Platte River indicated that depth retrieval in these environments is feasible, but might not be highly accurate. Four methods of calibrating image-derived depth estimates were evaluated. The first involved extracting image spectra at survey point locations throughout the reach. These paired observations of depth and reflectance were subjected to optimal band ratio analysis (OBRA) to relate (R2 = 0.596) a spectrally based quantity to flow depth. Two other methods were based on OBRA of data from individual cross sections. A fourth strategy used ground-based reflectance measurements to derive an OBRA relation (R2 = 0.944) that was then applied to the image. Depth retrieval accuracy was assessed by visually inspecting cross sections and calculating various error metrics. Calibration via field spectroscopy resulted in a shallow bias but provided relative accuracies similar to image-based methods. Reach-aggregated OBRA was marginally superior to calibrations based on individual cross sections, and depth retrieval accuracy varied considerably along each reach. Errors were lower and observed versus predicted regression R2 values higher for a relatively simple, deeper site than a shallower, braided reach; errors were 1/3 and 1/2 the mean depth for the two reaches. Bathymetric maps were coherent and hydraulically reasonable, however, and might be more reliable than implied by numerical metrics. As an example application, linear discriminant analysis was used to produce a series of depth threshold maps for characterizing shallow-water habitat for roosting cranes. ?? 2011 by the American Geophysical Union.
Legleiter, Carl J.; Kinzel, Paul J.; Overstreet, Brandon T.
2011-01-01
This study examined the possibility of mapping depth from optical image data in turbid, sediment-laden channels. Analysis of hyperspectral images from the Platte River indicated that depth retrieval in these environments is feasible, but might not be highly accurate. Four methods of calibrating image-derived depth estimates were evaluated. The first involved extracting image spectra at survey point locations throughout the reach. These paired observations of depth and reflectance were subjected to optimal band ratio analysis (OBRA) to relate (R2 = 0.596) a spectrally based quantity to flow depth. Two other methods were based on OBRA of data from individual cross sections. A fourth strategy used ground-based reflectance measurements to derive an OBRA relation (R2 = 0.944) that was then applied to the image. Depth retrieval accuracy was assessed by visually inspecting cross sections and calculating various error metrics. Calibration via field spectroscopy resulted in a shallow bias but provided relative accuracies similar to image-based methods. Reach-aggregated OBRA was marginally superior to calibrations based on individual cross sections, and depth retrieval accuracy varied considerably along each reach. Errors were lower and observed versus predicted regression R2 values higher for a relatively simple, deeper site than a shallower, braided reach; errors were 1/3 and 1/2 the mean depth for the two reaches. Bathymetric maps were coherent and hydraulically reasonable, however, and might be more reliable than implied by numerical metrics. As an example application, linear discriminant analysis was used to produce a series of depth threshold maps for characterizing shallow-water habitat for roosting cranes.
Deterministic Modeling of the High Temperature Test Reactor with DRAGON-HEXPEDITE
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. Ortensi; M.A. Pope; R.M. Ferrer
2010-10-01
The Idaho National Laboratory (INL) is tasked with the development of reactor physics analysis capability of the Next Generation Nuclear Power (NGNP) project. In order to examine the INL’s current prismatic reactor analysis tools, the project is conducting a benchmark exercise based on modeling the High Temperature Test Reactor (HTTR). This exercise entails the development of a model for the initial criticality, a 19 fuel column thin annular core, and the fully loaded core critical condition with 30 fuel columns. Special emphasis is devoted to physical phenomena and artifacts in HTTR that are similar to phenomena and artifacts in themore » NGNP base design. The DRAGON code is used in this study since it offers significant ease and versatility in modeling prismatic designs. DRAGON can generate transport solutions via Collision Probability (CP), Method of Characteristics (MOC) and Discrete Ordinates (Sn). A fine group cross-section library based on the SHEM 281 energy structure is used in the DRAGON calculations. The results from this study show reasonable agreement in the calculation of the core multiplication factor with the MC methods, but a consistent bias of 2–3% with the experimental values is obtained. This systematic error has also been observed in other HTTR benchmark efforts and is well documented in the literature. The ENDF/B VII graphite and U235 cross sections appear to be the main source of the error. The isothermal temperature coefficients calculated with the fully loaded core configuration agree well with other benchmark participants but are 40% higher than the experimental values. This discrepancy with the measurement partially stems from the fact that during the experiments the control rods were adjusted to maintain criticality, whereas in the model, the rod positions were fixed. In addition, this work includes a brief study of a cross section generation approach that seeks to decouple the domain in order to account for neighbor effects. This spectral interpenetration is a dominant effect in annular HTR physics. This analysis methodology should be further explored in order to reduce the error that is systematically propagated in the traditional generation of cross sections.« less
NASA Technical Reports Server (NTRS)
Semler, T. T.
1973-01-01
The method of pseudo-resonance cross sections is used to analyze published temperature-dependent neutron transmission and self-indication measurements on tantalum in the unresolved region. In the energy region analyzed, 1825.0 to 2017.0 eV, a direct application of the pseudo-resonance approach using a customary average strength function will not provide effective cross sections which fit the measured cross section behavior. Rather a local value of the strength function is required, and a set of resonances which model the measured behavior of the effective cross sections is derived. This derived set of resonance parameters adequately represents the observed resonance hehavior in this local energy region. Similar analyses for the measurements in other unresolved energy regions are necessary to obtain local resonance parameters for improved reactor calculations. This study suggests that Doppler coefficients calculated by sampling from grand average statistical distributions over the entire unresolved resonance region can be in error, since significant local variations in the statistical distributions are not taken into consideration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varlamov, V. V., E-mail: Varlamov@depni.sinp.msu.ru; Ishkhanov, B. S.; Orlin, V. N.
2016-07-15
Basic methods for determining cross sections for photoneutron partial reactions are examined. They are obtained directly in experiments with quasimonoeneregetic annihilation photons or from the cross section for the (γ, xn) = (γ, 1n) + 2(γ, 2n) + 3(γ, 3n) +... neutron-yield reaction in experiments with bremsstrahlung photons by introducing corrections based on statistical nuclear-reaction theory. The difference in the conditions of these experiments, which leads to discrepancies between their results because of sizable systematic errors, is analyzed. Physical criteria are used to study the reliability of data on the photodisintegration of {sup 133}Cs, {sup 138}Ba, and {sup 209}Bi nuclei.more » The cross sections for partial and total reactions satisfying the reliability criteria are evaluated within the experimental–theoretical method (σ{sup eval}(γ, in) = F{sub i}{sup theor} × σ{sup expt}(γ, xn)) on the basis of the experimental cross sections σ{sup expt}(γ, xn) and the results of the calculations within the combined model of photonuclear reactions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meadows, J.W.
1986-12-01
The measurement of the fission cross section ratios of nine isotopes relative to /sup 235/U at an average neutron energy of 14.74 MeV is described with particular attention to the determination of corrections and to sources of error. The results are compared to ENDF/B-V and to other measurements of the past decade. The ratio of the neutron induced fission cross section for these isotopes to the fission cross section for /sup 235/U are: /sup 230/Th - 0.290 +- 1.9%; /sup 232/Th - 0.191 +- 1.9%; /sup 233/U - 1.132 +- 0.7%; /sup 234/U - 0.998 +- 1.0%; /sup 236/U -more » 0.791 +- 1.1%; /sup 238/U - 0.587 +- 1.1%; /sup 237/Np - 1.060 +- 1.4%; /sup 239/Pu - 1.152 +- 1.1%; /sup 242/Pu - 0.967 +- 1.0%. 40 refs., 11 tabs., 9 figs.« less
Ozone Observations by the Gas and Aerosol Measurement Sensor during SOLVE II
NASA Technical Reports Server (NTRS)
Pitts, M. C.; Thomason, L. W.; Zawodny, J. M.; Wenny, B. N.; Livingston, J. M.; Russell, P. B.; Yee, J.-H.; Swartz, W. H.; Shetter, R. E.
2006-01-01
The Gas and Aerosol Measurement Sensor (GAMS) was deployed aboard the NASA DC-8 aircraft during the second SAGE III Ozone Loss and Validation Experiment (SOLVE II). GAMS acquired line-of-sight (LOS) direct solar irradiance spectra during the sunlit portions of ten science flights of the DC-8 between 12 January and 4 February 2003. Differential line-of-sight (DLOS) optical depth spectra are produced from the GAMS raw solar irradiance spectra. Then, DLOS ozone number densities are retrieved from the GAMS spectra using a multiple linear regression spectral fitting technique. Both the DLOS optical depth spectra and retrieved ozone data are compared with coincident measurements from two other solar instruments aboard the DC-8 platform to demonstrate the robustness and stability of the GAMS data. The GAMS ozone measurements are then utilized to evaluate the quality of the Wulf band ozone cross sections, a critical component of the SAGE III aerosol, water vapor, and temperature/pressure retrievals. Results suggest the ozone cross section compilation of Shettle and Anderson currently used operationally in SAGE III data processing may be in error by as much as 10-20% in theWulf bands, and their lack of reported temperature dependence is a significant deficiency. A second, more recent, cross section database compiled for the SCIAMACHY satellite mission appears to be of much better quality in the Wulf bands, but still may have errors as large as 5% near the Wulf band absorption peaks, which is slightly larger than their stated uncertainty. Additional laboratory measurements of the Wulf band cross sections should be pursued to further reduce their uncertainty and better quantify their temperature dependence.
Lin, Yu-Hua; Ma, Su-mei
2009-01-01
Underreporting of medication administering errors (MAEs) is a threat to the quality of nursing care. The reasons for MAEs are complex and vary by health professional and institution. The purpose of this study was to explore the prevalence of MAEs and the willingness of nurses to report them. A cross-sectional study was conducted involving a survey of 14 medical surgical hospitals in southern Taiwan. Nurses voluntarily participated in this study. A structured questionnaire was completed by 605 participants. Data were collected from February 1, 2005 to March 15, 2005 using the following instruments: MAEs Unwillingness to Report Scale, Medication Errors Etiology Questionnaire, and Personal Features Questionnaire. One additional question was used to identify the willingness of nurses to report medication errors: "When medication errors occur, should they be reported to the department?" This question helped to identify the willingness or lack thereof, to report incident errors. The results indicated that 66.9% of the nurses reported experiencing MAEs and 87.7% of the nurses had a willingness to report the MAEs if there were no consequences for reporting. The nurses' willingness to report MAEs differed by job position, nursing grade, type of hospital, and hospital funding. The final logistic regression model demonstrated hospital funding to be the only statistically significant factor. The odds of a willingness to report MAEs increased 2.66-fold in private hospitals (p = 0.032, CI = 1.09 to 6.49), and 3.28 in nonprofit hospitals (p = 0.00, CI = 1.73 to 6.21) when compared to public hospitals. This study demonstrates that reporting of MAEs should be anonymous and without negative consequences in order to monitor and guide improvements in hospital medication systems.
Ducru, Pablo; Josey, Colin; Dibert, Karia; ...
2017-01-25
This paper establishes a new family of methods to perform temperature interpolation of nuclear interactions cross sections, reaction rates, or cross sections times the energy. One of these quantities at temperature T is approximated as a linear combination of quantities at reference temperatures (T j). The problem is formalized in a cross section independent fashion by considering the kernels of the different operators that convert cross section related quantities from a temperature T 0 to a higher temperature T — namely the Doppler broadening operation. Doppler broadening interpolation of nuclear cross sections is thus here performed by reconstructing the kernelmore » of the operation at a given temperature T by means of linear combination of kernels at reference temperatures (T j). The choice of the L 2 metric yields optimal linear interpolation coefficients in the form of the solutions of a linear algebraic system inversion. The optimization of the choice of reference temperatures (T j) is then undertaken so as to best reconstruct, in the L∞ sense, the kernels over a given temperature range [T min,T max]. The performance of these kernel reconstruction methods is then assessed in light of previous temperature interpolation methods by testing them upon isotope 238U. Temperature-optimized free Doppler kernel reconstruction significantly outperforms all previous interpolation-based methods, achieving 0.1% relative error on temperature interpolation of 238U total cross section over the temperature range [300 K,3000 K] with only 9 reference temperatures.« less
Interatomic potentials for HeAr, HeKr, and HeXe from multiproperty fits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Danielson, L.J.; Keil, M.
1988-01-15
Crossed molecular beam measurements of differential cross sections (DCS) are reported for elastic scattering of He by Ar, Kr, and Xe at high resolution. Interatomic potentials are determined by simultaneously fitting the DCS's, as well as mixture viscosity and interaction second virial data. Bias due to systematic and potential model errors are examined and are used to estimate the accuracy of the potential energy curves obtained. Attractive well depths are 2.59, 2.67, and 2.64 meV +- 3% for HeAr, HeKr, and HeXe, respectively, agreeing with the best available HeAr potential and a previously proposed HeKr potential, but significantly deeper thanmore » previously reported potentials for HeXe. The HeXe attractive well is also considerably broader than previously reported. Attractive minimum positions are 3.48, 3.70, and 4.00 A ( +- 0.03 A) for HeAr, HeKr, and HeXe, respectively. Including the accurate diffusion data of Dunlop and co-workers (Physica A 95, 561 (1979)) and the absolute integral cross sections of Pirani and Vecchiocattivi (J. Chem. Phys. 66, 372 (1977) and revisions thereto) verify the error bounds for all three potentials.« less
NASA Technical Reports Server (NTRS)
Xia, T. J.; Chien, T. S.; Wu, C. Y. Robert; Judge, D. L.
1991-01-01
Using synchrotron radiation as a continuum light source, the photoabsorption and photoionization cross sections of NH3, PH3, H2S, C2H2, and C2H4 have been measured from their respective ionization thresholds to 1060 A. The vibrational constants associated with the nu(2) totally symmetric, out-of-plane bending vibration of the ground electronic state of PH3(+) have been obtained. The cross sections and quantum yields for producing neutral products through photoexcitation of these molecules in the given spectral regions have also been determined. In the present work, autoionization processes were found to be less important than dissociation and predissociation processes in NH3, PH3, and C2H4. Several experimental techniques have been employed in order to examine the various possible systematic errors critically.
Erratum: Measurement of σ(e+e-→ψ(3770)→hadrons) at Ec.m.=3773MeV [Phys. Rev. Lett. 96, 092002 (2006)
NASA Astrophysics Data System (ADS)
Besson, D.; Pedlar, T. K.; Cronin-Hennessy, D.; Gao, K. Y.; Gong, D. T.; Hietala, J.; Kubota, Y.; Klein, T.; Lang, B. W.; Poling, R.; Scott, A. W.; Smith, A.; Dobbs, S.; Metreveli, Z.; Seth, K. K.; Tomaradze, A.; Zweber, P.; Ernst, J.; Arms, K.; Severini, H.; Dytman, S. A.; Love, W.; Mehrabyan, S.; Mueller, J. A.; Savinov, V.; Li, Z.; Lopez, A.; Mendez, H.; Ramirez, J.; Huang, G. S.; Miller, D. H.; Pavlunin, V.; Sanghi, B.; Shipsey, I. P. J.; Adams, G. S.; Anderson, M.; Cummings, J. P.; Danko, I.; Napolitano, J.; He, Q.; Muramatsu, H.; Park, C. S.; Thorndike, E. H.; Coan, T. E.; Gao, Y. S.; Liu, F.; Artuso, M.; Boulahouache, C.; Blusk, S.; Butt, J.; Li, J.; Menaa, N.; Mountain, R.; Nisar, S.; Randrianarivony, K.; Redjimi, R.; Sia, R.; Skwarnicki, T.; Stone, S.; Wang, J. C.; Zhang, K.; Csorna, S. E.; Bonvicini, G.; Cinabro, D.; Dubrovin, M.; Lincoln, A.; Briere, R. A.; Chen, G. P.; Chen, J.; Ferguson, T.; Tatishvili, G.; Vogel, H.; Watkins, M. E.; Rosner, J. L.; Adam, N. E.; Alexander, J. P.; Berkelman, K.; Cassel, D. G.; Duboscq, J. E.; Ecklund, K. M.; Ehrlich, R.; Fields, L.; Gibbons, L.; Gray, R.; Gray, S. W.; Hartill, D. L.; Heltsley, B. K.; Hertz, D.; Jones, C. D.; Kandaswamy, J.; Kreinick, D. L.; Kuznetsov, V. E.; Mahlke-Krüger, H.; Meyer, T. O.; Onyisi, P. U. E.; Patterson, J. R.; Peterson, D.; Phillips, E. A.; Pivarski, J.; Riley, D.; Ryd, A.; Sadoff, A. J.; Schwarthoff, H.; Shi, X.; Stroiney, S.; Sun, W. M.; Wilksen, T.; Weinberger, M.; Athar, S. B.; Avery, P.; Breva-Newell, L.; Patel, R.; Potlia, V.; Stoeck, H.; Yelton, J.; Rubin, P.; Cawlfield, C.; Eisenstein, B. I.; Karliner, I.; Kim, D.; Lowrey, N.; Naik, P.; Sedlack, C.; Selen, M.; White, E. J.; Wiss, J.; Shepherd, M. R.; Asner, D. M.; Edwards, K. W.
2010-04-01
We have updated our measurement of the cross section for e^+e^- -> psi(3770) -> hadrons, our publication "Measurement of sigma(e^+e^- -> psi(3770) -> hadrons) at E_{c.m.} = 3773 MeV", arXiv:hep-ex/0512038, Phys.Rev.Lett.96, 092002 (2006). Simultaneous with this arXiv update, we have published an erratum in Phys.Rev.Lett.104, 159901 (2010). There, and in this update, we have corrected a mistake in the computation of the error on the difference of the cross sections for e^+e^- -> psi(3770) -> hadrons and e^+e^- -> psi(3770) -> DDbar. We have also used a more recent CLEO measurement of cross section for e^+e^- -> psi(3770) -> DDbar. From this, we obtain an upper limit on the branching fraction for psi(3770) -> non-DDbar of 9% at 90% confidence level.
Mehdizadeh, Mojdeh; Ahmadi, Navid; Jamshidi, Mahsa
2014-11-01
Exact location of the inferior alveolar nerve (IAN) bundle is very important. The aim of this study is to evaluate the relationship between the mandibular third molar and the mandibular canal by cone-beam computed tomography. This was a cross-sectional study with convenience sampling. 94 mandibular CBCTs performed with CSANEX 3D machine (Soredex, Finland) and 3D system chosen. Vertical and horizontal relationship between the mandibular canal and the third molar depicted by 3D, panoramic reformat view of CBCT and cross-sectional view. Cross-sectional view was our gold standard and other view evaluated by it. There were significant differences between the vertical and horizontal relation of nerve and tooth in all views (p < 0.001). The results showed differences in the position of the inferior alveolar nerve with different views of CBCT, so CBCT images are not quite reliable and have possibility of error.
Systematic errors in long baseline oscillation experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Deborah A.; /Fermilab
This article gives a brief overview of long baseline neutrino experiments and their goals, and then describes the different kinds of systematic errors that are encountered in these experiments. Particular attention is paid to the uncertainties that come about because of imperfect knowledge of neutrino cross sections and more generally how neutrinos interact in nuclei. Near detectors are planned for most of these experiments, and the extent to which certain uncertainties can be reduced by the presence of near detectors is also discussed.
Charge Exchange of Highly Charged Ne and Mg Ions with H and He
NASA Astrophysics Data System (ADS)
Lyons, D.; Cumbee, R. S.; Stancil, P. C.
2017-10-01
Cross sections for single electron capture (SEC), or charge exchange (CX), in collisions of Ne(8-10)+ and Mg(8-12)+ with H and He, are computed using an approximate multichannel Landau-Zener (MCLZ) formalism. Final-state-resolved cross sections for the principal (n), orbital angular momentum (ℓ), and where appropriate, total spin angular momentum (S) quantum numbers are explicitly computed, except for the incident bare ions Ne10+ and Mg12+. In the latter two cases, n{\\ell }-resolution is obtained from analytical ℓ-distribution functions applied to n-resolved MCLZ cross sections. In all cases, the cross sections are computed over the collision energy range 1 meV/u to 50 keV/u with LZ parameters estimated from atomic energies obtained from experiment, theory, or, in the case of high-lying Rydberg levels, estimated with a quantum defect approach. Errors in the energy differences in the adiabatic potentials at the avoided crossing distances give the largest contribution to the uncertainties in the cross sections, which are expected to increase with decreasing cross section magnitude. The energy differences are deduced here with the Olson-Salop-Tauljberg radial coupling model. Proper selection of an ℓ-distribution function for bare ion collisions introduces another level of uncertainty into the results. Comparison is made to existing experimental or theoretical results when available, but such data are absent for most considered collision systems. The n{\\ell }S-resolved SEC cross sections are used in an optically thin cascade simulation to predict X-ray spectra and line ratios that will aid in modeling the X-ray emission in environments where CX is an important mechanism. Details on a MCLZ computational package, Stueckelberg, are also provided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meadows, J.; Smith, D.; Greenwood, L.
Four sample packets containing elemental Ti, Fe, Ni, Cu, Nb, Ag, Eu, Tb and Hf have been irradiated in three distinct accelerator neutron fields, at Argonne National Laboratory and Los Alamos National Laboratory, USA, and Japan Atomic Energy Research Institute, Tokai, Japan. The acquired experimental data include differential cross sections and integral cross sections for the continuum neutron spectrum produced by 7-MeV deuterons incident on thick Be-metal target. The U-238(n,f) cross section was also measured at 10.3 MeV as a consistency check on the experimental technique. This the third progress report on a project which has been carried out undermore » the auspices of an IAEA Coordinated Research Program entitled ``Activation Cross Sections for the Generation Of Long-lived Radionuclides of Importance in Fusion Reactor Technology``. The present report provides the latest results from this work. Comparison is made between the 14.7-MeV cross-section values obtained from the separate investigations at Argonne and JAERI. Generally, good agreement observed within the experimental errors when consistent sample parameters, radioactivity decay data and reference cross values are employed. A comparison is also made between the experimental results and those derived from calculations using a nuclear model. Experimental neutron information on the Be(d,n) neutron spectrum was incorporated in the comparisons for the integral results. The agreement is satisfactory considering the various uncertainties that are involved.« less
ERROR IN ANNUAL AVERAGE DUE TO USE OF LESS THAN EVERYDAY MEASUREMENTS
Long term averages of the concentration of PM mass and components are of interest for determining compliance with annual averages, for developing exposure surrogated for cross-sectional epidemiologic studies of the long-term of PM, and for determination of aerosol sources by chem...
Development of Biological Acoustic Impedance Microscope and its Error Estimation
NASA Astrophysics Data System (ADS)
Hozumi, Naohiro; Nakano, Aiko; Terauchi, Satoshi; Nagao, Masayuki; Yoshida, Sachiko; Kobayashi, Kazuto; Yamamoto, Seiji; Saijo, Yoshifumi
This report deals with the scanning acoustic microscope for imaging cross sectional acoustic impedance of biological soft tissues. A focused acoustic beam was transmitted to the tissue object mounted on the "rear surface" of plastic substrate. A cerebellum tissue of rat and a reference material were observed at the same time under the same condition. As the incidence is not vertical, not only longitudinal wave but also transversal wave is generated in the substrate. The error in acoustic impedance assuming vertical incidence was estimated. It was proved that the error can precisely be compensated, if the beam pattern and acoustic parameters of coupling medium and substrate had been known.
Sada, Oumer; Melkie, Addisu; Shibeshi, Workineh
2015-09-16
Medication errors (MEs) are important problems in all hospitalized populations, especially in intensive care unit (ICU). Little is known about the prevalence of medication prescribing errors in the ICU of hospitals in Ethiopia. The aim of this study was to assess medication prescribing errors in the ICU of Tikur Anbessa Specialized Hospital using retrospective cross-sectional analysis of patient cards and medication charts. About 220 patient charts were reviewed with a total of 1311 patient-days, and 882 prescription episodes. 359 MEs were detected; with prevalence of 40 per 100 orders. Common prescribing errors were omission errors 154 (42.89%), 101 (28.13%) wrong combination, 48 (13.37%) wrong abbreviation, 30 (8.36%) wrong dose, wrong frequency 18 (5.01%) and wrong indications 8 (2.23%). The present study shows that medication errors are common in medical ICU of Tikur Anbessa Specialized Hospital. These results suggest future targets of prevention strategies to reduce the rate of medication error.
Medical error and related factors during internship and residency.
Ahmadipour, Habibeh; Nahid, Mortazavi
2015-01-01
It is difficult to determine the real incidence of medical errors due to the lack of a precise definition of errors, as well as the failure to report them under certain circumstances. We carried out a cross- sectional study in Kerman University of Medical Sciences, Iran in 2013. The participants were selected through the census method. The data were collected using a self-administered questionnaire, which consisted of questions on the participants' demographic data and questions on the medical errors committed. The data were analysed by SPSS 19. It was found that 270 participants had committed medical errors. There was no significant difference in the frequency of errors committed by interns and residents. In the case of residents, the most common error was misdiagnosis and in that of interns, errors related to history-taking and physical examination. Considering that medical errors are common in the clinical setting, the education system should train interns and residents to prevent the occurrence of errors. In addition, the system should develop a positive attitude among them so that they can deal better with medical errors.
The Longitudinal Association between Oppositional and Depressive Symptoms across Childhood
ERIC Educational Resources Information Center
Boylan, Khrista; Georgiades, Katholiki; Szatmari, Peter
2010-01-01
Objective: Symptoms of oppositional defiant disorder (ODD) and depression show high rates of co-occurrence, both cross-sectionally and longitudinally. This study examines the extent to which variation in oppositional symptoms predict, variation in depressive symptoms over time, accounting for co-occurring depressive symptoms and measurement error.…
Error Processing and Gender-Shared and -Specific Neural Predictors of Relapse in Cocaine Dependence
ERIC Educational Resources Information Center
Luo, Xi; Zhang, Sheng; Hu, Sien; Bednarski, Sarah R.; Erdman, Emily; Farr, Olivia M.; Hong, Kwang-Ik; Sinha, Rajita; Mazure, Carolyn M.; Li, Chiang-shan R.
2013-01-01
Deficits in cognitive control are implicated in cocaine dependence. Previously, combining functional magnetic resonance imaging and a stop signal task, we demonstrated altered cognitive control in cocaine-dependent individuals. However, the clinical implications of these cross-sectional findings and, in particular, whether the changes were…
NASA Astrophysics Data System (ADS)
Ali, E. S. M.; Spencer, B.; McEwen, M. R.; Rogers, D. W. O.
2015-02-01
In this study, a quantitative estimate is derived for the uncertainty in the XCOM photon mass attenuation coefficients in the energy range of interest to external beam radiation therapy—i.e. 100 keV (orthovoltage) to 25 MeV—using direct comparisons of experimental data against Monte Carlo models and theoretical XCOM data. Two independent datasets are used. The first dataset is from our recent transmission measurements and the corresponding EGSnrc calculations (Ali et al 2012 Med. Phys. 39 5990-6003) for 10-30 MV photon beams from the research linac at the National Research Council Canada. The attenuators are graphite and lead, with a total of 140 data points and an experimental uncertainty of ˜0.5% (k = 1). An optimum energy-independent cross section scaling factor that minimizes the discrepancies between measurements and calculations is used to deduce cross section uncertainty. The second dataset is from the aggregate of cross section measurements in the literature for graphite and lead (49 experiments, 288 data points). The dataset is compared to the sum of the XCOM data plus the IAEA photonuclear data. Again, an optimum energy-independent cross section scaling factor is used to deduce the cross section uncertainty. Using the average result from the two datasets, the energy-independent cross section uncertainty estimate is 0.5% (68% confidence) and 0.7% (95% confidence). The potential for energy-dependent errors is discussed. Photon cross section uncertainty is shown to be smaller than the current qualitative ‘envelope of uncertainty’ of the order of 1-2%, as given by Hubbell (1999 Phys. Med. Biol 44 R1-22).
Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; ...
2017-03-29
We presented a measurement of the double-differential inclusive jet cross section as a function of the jet transverse momentum p T and the absolute jet rapidity abs(y). Data from LHC proton-proton collisions at √s = 8 TeV, corresponding to an integrated luminosity of 19.7 inverse femtobarns, have been collected with the CMS detector. Jets are reconstructed using the anti-k T clustering algorithm with a size parameter of 0.7 in a phase space region covering jet p T from 74 GeV up to 2.5 TeV and jet absolute rapidity up to abs(y) = 3.0. The low-p T jet range between 21 and 74 GeV is also studied up to abs(y) = 4.7, using a dedicated data sample corresponding to an integrated luminosity of 5.6 inverse picobarns. Furthermore, the measured jet cross section is corrected for detector effects and compared with the predictions from perturbative QCD at next-to-leading order (NLO) using various sets of parton distribution functions (PDF). Cross section ratios to the corresponding measurements performed at 2.76 and 7 TeV are presented. From the measured double-differential jet cross section, the value of the strong coupling constant evaluated at the Z mass is α S(M Z) = 0.1164more » $$+0.0060\\atop{-0.0043}$$, where the errors include the PDF, scale, nonperturbative effects and experimental uncertainties, using the CT10 NLO PDFs. Finally, improved constraints on PDFs based on the inclusive jet cross section measurement are presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.
We presented a measurement of the double-differential inclusive jet cross section as a function of the jet transverse momentum p T and the absolute jet rapidity abs(y). Data from LHC proton-proton collisions at √s = 8 TeV, corresponding to an integrated luminosity of 19.7 inverse femtobarns, have been collected with the CMS detector. Jets are reconstructed using the anti-k T clustering algorithm with a size parameter of 0.7 in a phase space region covering jet p T from 74 GeV up to 2.5 TeV and jet absolute rapidity up to abs(y) = 3.0. The low-p T jet range between 21 and 74 GeV is also studied up to abs(y) = 4.7, using a dedicated data sample corresponding to an integrated luminosity of 5.6 inverse picobarns. Furthermore, the measured jet cross section is corrected for detector effects and compared with the predictions from perturbative QCD at next-to-leading order (NLO) using various sets of parton distribution functions (PDF). Cross section ratios to the corresponding measurements performed at 2.76 and 7 TeV are presented. From the measured double-differential jet cross section, the value of the strong coupling constant evaluated at the Z mass is α S(M Z) = 0.1164more » $$+0.0060\\atop{-0.0043}$$, where the errors include the PDF, scale, nonperturbative effects and experimental uncertainties, using the CT10 NLO PDFs. Finally, improved constraints on PDFs based on the inclusive jet cross section measurement are presented.« less
NASA Astrophysics Data System (ADS)
Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Hartl, C.; Hörmann, N.; Hrubec, J.; Jeitler, M.; König, A.; Krätschmer, I.; Liko, D.; Matsushita, T.; Mikulec, I.; Rabady, D.; Rad, N.; Rahbaran, B.; Rohringer, H.; Schieck, J.; Strauss, J.; Treberer-Treberspurg, W.; Waltenberger, W.; Wulz, C.-E.; Mossolov, V.; Shumeiko, N.; Suarez Gonzalez, J.; Alderweireldt, S.; De Wolf, E. A.; Janssen, X.; Lauwers, J.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Van Spilbeeck, A.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; Daci, N.; De Bruyn, I.; Deroover, K.; Heracleous, N.; Lowette, S.; Moortgat, S.; Moreels, L.; Olbrechts, A.; Python, Q.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Parijs, I.; Brun, H.; Caillol, C.; Clerbaux, B.; De Lentdecker, G.; Delannoy, H.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Léonard, A.; Luetic, J.; Maerschalk, T.; Marinov, A.; Randle-conde, A.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Yonamine, R.; Zenoni, F.; Zhang, F.; Cimmino, A.; Cornelis, T.; Dobur, D.; Fagot, A.; Garcia, G.; Gul, M.; Poyraz, D.; Salva, S.; Schöfbeck, R.; Tytgat, M.; Van Driessche, W.; Yazgan, E.; Zaganidis, N.; Beluffi, C.; Bondu, O.; Brochet, S.; Bruno, G.; Caudron, A.; Ceard, L.; De Visscher, S.; Delaere, C.; Delcourt, M.; Forthomme, L.; Francois, B.; Giammanco, A.; Jafari, A.; Jez, P.; Komm, M.; Lemaitre, V.; Magitteri, A.; Mertens, A.; Musich, M.; Nuttens, C.; Piotrzkowski, K.; Quertenmont, L.; Selvaggi, M.; Vidal Marono, M.; Wertz, S.; Beliy, N.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Custódio, A.; Da Costa, E. M.; Da Silveira, G. G.; De Jesus Damiao, D.; De Oliveira Martins, C.; Fonseca De Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Matos Figueiredo, D.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Prado Da Silva, W. L.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; Dogra, S.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Moon, C. S.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Rodozov, M.; Stoykova, S.; Sultanov, G.; Vutova, M.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Fang, W.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Chen, Y.; Cheng, T.; Jiang, C. H.; Leggat, D.; Liu, Z.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Zhang, H.; Zhao, J.; Asawatangtrakuldee, C.; Ban, Y.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; Gomez, J. P.; González Hernández, C. F.; Ruiz Alvarez, J. D.; Sanabria, J. C.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Ferencek, D.; Kadija, K.; Micanovic, S.; Sudic, L.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Finger, M.; Finger, M.; Carrera Jarrin, E.; Assran, Y.; Elkafrawy, T.; Ellithi Kamel, A.; Mahrous, A.; Calpas, B.; Kadastik, M.; Murumaa, M.; Perrini, L.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Peltola, T.; Tuominiemi, J.; Tuovinen, E.; Wendland, L.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Fabbro, B.; Faure, J. L.; Favaro, C.; Ferri, F.; Ganjour, S.; Ghosh, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Kucher, I.; Locci, E.; Machet, M.; Malcles, J.; Rander, J.; Rosowsky, A.; Titov, M.; Zghiche, A.; Abdulsalam, A.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Chapon, E.; Charlot, C.; Davignon, O.; Granier de Cassagnac, R.; Jo, M.; Lisniak, S.; Miné, P.; Naranjo, I. N.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Regnard, S.; Salerno, R.; Sirois, Y.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Agram, J.-L.; Andrea, J.; Aubin, A.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Le Bihan, A.-C.; Merlin, J. A.; Skovpen, K.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Bouvier, E.; Carrillo Montoya, C. A.; Chierici, R.; Contardo, D.; Courbon, B.; Depasse, P.; El Mamouni, H.; Fan, J.; Fay, J.; Gascon, S.; Gouzevitch, M.; Grenier, G.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Popov, A.; Sabes, D.; Sordini, V.; Vander Donckt, M.; Verdier, P.; Viret, S.; Khvedelidze, A.; Lomidze, D.; Autermann, C.; Beranek, S.; Feld, L.; Heister, A.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Ostapchuk, A.; Preuten, M.; Raupach, F.; Schael, S.; Schomakers, C.; Schulte, J. F.; Schulz, J.; Verlage, T.; Weber, H.; Zhukov, V.; Brodski, M.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Olschewski, M.; Padeken, K.; Papacz, P.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Sonnenschein, L.; Teyssier, D.; Thüer, S.; Cherepanov, V.; Erdogan, Y.; Flügge, G.; Hoehle, F.; Kargoll, B.; Kress, T.; Künsken, A.; Lingemann, J.; Nehrkorn, A.; Nowack, A.; Nugent, I. M.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Asin, I.; Beernaert, K.; Behnke, O.; Behrens, U.; Bin Anuar, A. A.; Borras, K.; Campbell, A.; Connor, P.; Contreras-Campana, C.; Costanza, F.; Diez Pardos, C.; Dolinska, G.; Eckerlin, G.; Eckstein, D.; Eren, E.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Grados Luyando, J. M.; Gunnellini, P.; Harb, A.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Karacheban, O.; Kasemann, M.; Keaveney, J.; Kieseler, J.; Kleinwort, C.; Korol, I.; Kuprash, O.; Lange, W.; Lelek, A.; Leonard, J.; Lipka, K.; Lobanov, A.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Ntomari, E.; Pitzl, D.; Placakyte, R.; Raspereza, A.; Roland, B.; Sahin, M. Ö.; Saxena, P.; Schoerner-Sadenius, T.; Seitz, C.; Spannagel, S.; Stefaniuk, N.; Trippkewitz, K. D.; Van Onsem, G. P.; Walsh, R.; Wissing, C.; Blobel, V.; Centis Vignali, M.; Draeger, A. R.; Dreyer, T.; Garutti, E.; Goebel, K.; Gonzalez, D.; Haller, J.; Hoffmann, M.; Junkes, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Lapsien, T.; Lenz, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Niedziela, M.; Nowatschin, D.; Ott, J.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Poehlsen, J.; Sander, C.; Scharf, C.; Schleper, P.; Schmidt, A.; Schumann, S.; Schwandt, J.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Stöver, M.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Barth, C.; Baus, C.; Berger, J.; Butz, E.; Chwalek, T.; Colombo, F.; De Boer, W.; Dierlamm, A.; Fink, S.; Friese, R.; Giffels, M.; Gilbert, A.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Katkov, I.; Kornmayer, A.; Lobelle Pardo, P.; Maier, B.; Mildner, H.; Mozer, M. U.; Müller, T.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Röcker, S.; Roscher, F.; Schröder, M.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wagner-Kuhr, J.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Topsis-Giotis, I.; Agapitos, A.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Tziaferi, E.; Evangelou, I.; Flouris, G.; Foudas, C.; Kokkas, P.; Loukas, N.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Filipovic, N.; Bencze, G.; Hajdu, C.; Hidas, P.; Horvath, D.; Sikler, F.; Veszpremi, V.; Vesztergombi, G.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Molnar, J.; Szillasi, Z.; Bartók, M.; Makovec, A.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Bahinipati, S.; Choudhury, S.; Mal, P.; Mandal, K.; Nayak, A.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chawla, R.; Gupta, R.; Bhawandeep, U.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Mehta, A.; Mittal, M.; Singh, J. B.; Walia, G.; Kumar, Ashok; Bhardwaj, A.; Choudhary, B. C.; Garg, R. B.; Keshri, S.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Nishu, N.; Ranjan, K.; Sharma, R.; Sharma, V.; Bhattacharya, R.; Bhattacharya, S.; Chatterjee, K.; Dey, S.; Dutt, S.; Dutta, S.; Ghosh, S.; Majumdar, N.; Modak, A.; Mondal, K.; Mukhopadhyay, S.; Nandan, S.; Purohit, A.; Roy, A.; Roy, D.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Thakur, S.; Behera, P. K.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Netrakanti, P. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Dugad, S.; Kole, G.; Mahakud, B.; Mitra, S.; Mohanty, G. B.; Sur, N.; Sutar, B.; Banerjee, S.; Bhowmik, S.; Dewanjee, R. K.; Ganguly, S.; Guchait, M.; Jain, Sa.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Parida, B.; Sarkar, T.; Wickramage, N.; Chauhan, S.; Dube, S.; Kapoor, A.; Kothekar, K.; Rane, A.; Sharma, S.; Bakhshiansohi, H.; Behnamian, H.; Chenarani, S.; Eskandari Tadavani, E.; Etesami, S. M.; Fahim, A.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Caputo, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Fiore, L.; Iaselli, G.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Silvestris, L.; Venditti, R.; Verwilligen, P.; Abbiendi, G.; Battilana, C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Brigliadori, L.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Albergo, S.; Chiorboli, M.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Gori, V.; Lenzi, P.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Lo Vetere, M.; Monge, M. R.; Robutti, E.; Tosi, S.; Brianza, L.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Ghezzi, A.; Govoni, P.; Malvezzi, S.; Manzoni, R. A.; Marzocchi, B.; Menasce, D.; Moroni, L.; Paganoni, M.; Pedrini, D.; Pigazzini, S.; Ragazzi, S.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; De Nardo, G.; Di Guida, S.; Esposito, M.; Fabozzi, F.; Iorio, A. O. M.; Lanza, G.; Lista, L.; Meola, S.; Merola, M.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Azzi, P.; Bacchetta, N.; Benato, L.; Biasotto, M.; Boletti, A.; Carvalho Antunes De Oliveira, A.; Dall'Osso, M.; De Castro Manzano, P.; Dorigo, T.; Dosselli, U.; Fantinel, S.; Fanzago, F.; Gasparini, F.; Gasparini, U.; Gulmini, M.; Lacaprara, S.; Margoni, M.; Meneguzzo, A. T.; Pazzini, J.; Pozzobon, N.; Ronchese, P.; Torassa, E.; Ventura, S.; Zanetti, M.; Zotto, P.; Zucchetta, A.; Zumerle, G.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Bilei, G. M.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Leonardi, R.; Mantovani, G.; Menichelli, M.; Saha, A.; Santocchia, A.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Bernardini, J.; Boccali, T.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; Cipriani, M.; D'imperio, G.; Del Re, D.; Diemoz, M.; Gelli, S.; Jorda, C.; Longo, E.; Margaroli, F.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bartosik, N.; Bellan, R.; Biino, C.; Cartiglia, N.; Cenna, F.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Finco, L.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Shchelina, K.; Sola, V.; Solano, A.; Staiano, A.; Traczyk, P.; Belforte, S.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; La Licata, C.; Schizzi, A.; Zanetti, A.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Lee, S.; Lee, S. W.; Oh, Y. D.; Sekmen, S.; Son, D. C.; Yang, Y. C.; Kim, H.; Lee, A.; Brochero Cifuentes, J. A.; Kim, T. J.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Ha, S.; Hong, B.; Jo, Y.; Kim, Y.; Lee, B.; Lee, K.; Lee, K. S.; Lee, S.; Lim, J.; Park, S. K.; Roh, Y.; Almond, J.; Kim, J.; Oh, S. B.; Seo, S. h.; Yang, U. K.; Yoo, H. D.; Yu, G. B.; Choi, M.; Kim, H.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Ryu, G.; Ryu, M. S.; Choi, Y.; Goh, J.; Hwang, C.; Kim, D.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Komaragiri, J. R.; Ali, M. A. B. Md; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Hernandez-Almada, A.; Lopez-Fernandez, R.; Mejia Guisao, J.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Oropeza Barrera, C.; Vazquez Valencia, F.; Carpinteyro, S.; Pedraza, I.; Salazar Ibarguen, H. A.; Uribe Estrada, C.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Khan, W. A.; Shah, M. A.; Shoaib, M.; Waqas, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Romanowska-Rybinska, K.; Szleper, M.; Zalewski, P.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Walczak, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Di Francesco, A.; Faccioli, P.; Ferreira Parracho, P. G.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nemallapudi, M. V.; Rodrigues Antunes, J.; Seixas, J.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Vischia, P.; Afanasiev, S.; Bunin, P.; Golutvin, I.; Karjavin, V.; Korenkov, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Mitsyn, V. V.; Moisenz, P.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Tikhonenko, E.; Voytishin, N.; Zarubin, A.; Chtchipounov, L.; Golovtsov, V.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Murzin, V.; Oreshkin, V.; Sulimov, V.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Toms, M.; Vlasov, E.; Zhokin, A.; Chistov, R.; Rusinov, V.; Tarkovskii, E.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Rusakov, S. V.; Terkulov, A.; Baskakov, A.; Belyaev, A.; Boos, E.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Snigirev, A.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Elumakhov, D.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Krychkine, V.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Cirkovic, P.; Devetak, D.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Calvo, E.; Cerrada, M.; Chamizo Llatas, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Navarro De Martino, E.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Soares, M. S.; de Trocóniz, J. F.; Missiroli, M.; Moran, D.; Cuevas, J.; Fernandez Menendez, J.; Gonzalez Caballero, I.; González Fernández, J. R.; Palencia Cortezon, E.; Sanchez Cruz, S.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Castiñeiras De Saa, J. R.; Curras, E.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Martinez Rivero, C.; Matorras, F.; Piedra Gomez, J.; Rodrigo, T.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Auzinger, G.; Bachtis, M.; Baillon, P.; Ball, A. H.; Barney, D.; Bloch, P.; Bocci, A.; Bonato, A.; Botta, C.; Camporesi, T.; Castello, R.; Cepeda, M.; Cerminara, G.; D'Alfonso, M.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Guio, F.; De Roeck, A.; Di Marco, E.; Dobson, M.; Dordevic, M.; Dorney, B.; du Pree, T.; Duggan, D.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Fartoukh, S.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gill, K.; Girone, M.; Glege, F.; Gulhan, D.; Gundacker, S.; Guthoff, M.; Hammer, J.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Kirschenmann, H.; Knünz, V.; Kortelainen, M. J.; Kousouris, K.; Krammer, M.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Malgeri, L.; Mannelli, M.; Martelli, A.; Meijers, F.; Mersi, S.; Meschi, E.; Moortgat, F.; Morovic, S.; Mulders, M.; Neugebauer, H.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Ruan, M.; Sakulin, H.; Sauvan, J. B.; Schäfer, C.; Schwick, C.; Seidel, M.; Sharma, A.; Silva, P.; Simon, M.; Sphicas, P.; Steggemann, J.; Stoye, M.; Takahashi, Y.; Tosi, M.; Treille, D.; Triossi, A.; Tsirou, A.; Veckalns, V.; Veres, G. I.; Wardle, N.; Wöhri, H. K.; Zagozdzinska, A.; Zeuner, W. D.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Bachmair, F.; Bäni, L.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegà, M.; Eller, P.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lecomte, P.; Lustermann, W.; Mangano, B.; Marionneau, M.; Martinez Ruiz del Arbol, P.; Masciovecchio, M.; Meinhard, M. T.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrin, G.; Perrozzi, L.; Quittnat, M.; Rossini, M.; Schönenberger, M.; Starodumov, A.; Takahashi, M.; Tavolaro, V. R.; Theofilatos, K.; Wallny, R.; Aarrestad, T. K.; Amsler, C.; Caminada, L.; Canelli, M. F.; Chiochia, V.; De Cosa, A.; Galloni, C.; Hinzmann, A.; Hreus, T.; Kilminster, B.; Lange, C.; Ngadiuba, J.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Yang, Y.; Candelise, V.; Doan, T. H.; Jain, Sh.; Khurana, R.; Konyushikhin, M.; Kuo, C. M.; Lin, W.; Lu, Y. J.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chang, Y. H.; Chang, Y. W.; Chao, Y.; Chen, K. F.; Chen, P. H.; Dietz, C.; Fiori, F.; Hou, W.-S.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Miñano Moya, M.; Paganis, E.; Psallidas, A.; Tsai, J. f.; Tzeng, Y. M.; Asavapibhop, B.; Singh, G.; Srimanobhas, N.; Suwonjandee, N.; Adiguzel, A.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Girgis, S.; Gokbulut, G.; Guler, Y.; Gurpinar, E.; Hos, I.; Kangal, E. E.; Kara, O.; Kayis Topaksu, A.; Kiminsu, U.; Oglakci, M.; Onengut, G.; Ozdemir, K.; Sunar Cerci, D.; Topakli, H.; Turkcapar, S.; Zorbakir, I. S.; Zorbilmez, C.; Bilin, B.; Bilmis, S.; Isildak, B.; Karapinar, G.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Yetkin, E. A.; Yetkin, T.; Cakir, A.; Cankocak, K.; Sen, S.; Grynyov, B.; Levchuk, L.; Sorokin, P.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Burns, D.; Clement, E.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Smith, D.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Baber, M.; Bainbridge, R.; Buchmuller, O.; Bundock, A.; Burton, D.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; De Wit, A.; Della Negra, M.; Dunne, P.; Elwood, A.; Futyan, D.; Haddad, Y.; Hall, G.; Iles, G.; Lane, R.; Laner, C.; Lucas, R.; Lyons, L.; Magnan, A.-M.; Malik, S.; Mastrolorenzo, L.; Nash, J.; Nikitenko, A.; Pela, J.; Penning, B.; Pesaresi, M.; Raymond, D. M.; Richards, A.; Rose, A.; Seez, C.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Leslie, D.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Charaf, O.; Cooper, S. I.; Henderson, C.; Rumerio, P.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Benelli, G.; Berry, E.; Cutts, D.; Garabedian, A.; Hakala, J.; Heintz, U.; Jesus, O.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Piperov, S.; Sagir, S.; Spencer, E.; Syarif, R.; Breedon, R.; Breto, G.; Burns, D.; Calderon De La Barca Sanchez, M.; Chauhan, S.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Flores, C.; Funk, G.; Gardner, M.; Ko, W.; Lander, R.; Mclean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Ricci-Tam, F.; Shalhout, S.; Smith, J.; Squires, M.; Stolp, D.; Tripathi, M.; Wilbur, S.; Yohay, R.; Cousins, R.; Everaerts, P.; Florent, A.; Hauser, J.; Ignatenko, M.; Saltzberg, D.; Takasugi, E.; Valuev, V.; Weber, M.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Hanson, G.; Heilman, J.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Malberti, M.; Olmedo Negrete, M.; Paneva, M. I.; Shrinivas, A.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cerati, G. B.; Cittolin, S.; Derdzinski, M.; Gerosa, R.; Holzner, A.; Klein, D.; Letts, J.; Macneill, I.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Welke, C.; Wood, J.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Bhandari, R.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Flowers, K.; Franco Sevilla, M.; Geffert, P.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Heller, R.; Incandela, J.; Mccoll, N.; Mullin, S. D.; Ovcharova, A.; Richman, J.; Stuart, D.; Suarez, I.; West, C.; Yoo, J.; Anderson, D.; Apresyan, A.; Bendavid, J.; Bornheim, A.; Bunn, J.; Chen, Y.; Duarte, J.; Mott, A.; Newman, H. B.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhu, R. Y.; Andrews, M. B.; Azzolini, V.; Carlson, B.; Ferguson, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Mulholland, T.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; Mirman, N.; Nicolas Kaufman, G.; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Tan, S. M.; Tao, Z.; Thom, J.; Tucker, J.; Wittich, P.; Winn, D.; Abdullin, S.; Albrow, M.; Apollinari, G.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Cheung, H. W. K.; Chlebana, F.; Cihangir, S.; Cremonesi, M.; Elvira, V. D.; Fisk, I.; Freeman, J.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Hare, D.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Lammel, S.; Linacre, J.; Lincoln, D.; Lipton, R.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Magini, N.; Marraffino, J. M.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; Newman-Holmes, C.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Ristori, L.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Brinkerhoff, A.; Carnes, A.; Carver, M.; Curry, D.; Das, S.; Field, R. D.; Furic, I. K.; Konigsberg, J.; Korytov, A.; Ma, P.; Matchev, K.; Mei, H.; Milenovic, P.; Mitselmakher, G.; Rank, D.; Shchutska, L.; Sperka, D.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Linn, S.; Markowitz, P.; Martinez, G.; Rodriguez, J. L.; Ackert, A.; Adams, J. R.; Adams, T.; Askew, A.; Bein, S.; Diamond, B.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Khatiwada, A.; Prosper, H.; Santra, A.; Weinberg, M.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Bucinskaite, I.; Cavanaugh, R.; Evdokimov, O.; Gauthier, L.; Gerber, C. E.; Hofman, D. J.; Kurt, P.; O'Brien, C.; Sandoval Gonzalez, I. D.; Turner, P.; Varelas, N.; Wu, Z.; Zakaria, M.; Zhang, J.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Anderson, I.; Blumenfeld, B.; Cocoros, A.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Osherson, M.; Roskes, J.; Sarica, U.; Swartz, M.; Xiao, M.; Xin, Y.; You, C.; Al-bataineh, A.; Baringer, P.; Bean, A.; Bowen, J.; Bruner, C.; Castle, J.; Kenny, R. P.; Kropivnitskaya, A.; Majumder, D.; Mcbrayer, W.; Murray, M.; Sanders, S.; Stringer, R.; Tapia Takaki, J. D.; Wang, Q.; Ivanov, A.; Kaadze, K.; Khalil, S.; Makouski, M.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Lange, D.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Gomez, J. A.; Hadley, N. J.; Jabeen, S.; Kellogg, R. G.; Kolberg, T.; Kunkle, J.; Lu, Y.; Mignerey, A. C.; Shin, Y. H.; Skuja, A.; Tonjes, M. B.; Tonwar, S. C.; Apyan, A.; Barbieri, R.; Baty, A.; Bi, R.; Bierwagen, K.; Brandt, S.; Busza, W.; Cali, I. A.; Demiragli, Z.; Di Matteo, L.; Gomez Ceballos, G.; Goncharov, M.; Hsu, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Krajczar, K.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Sumorok, K.; Tatar, K.; Varma, M.; Velicanu, D.; Veverka, J.; Wang, J.; Wang, T. W.; Wyslouch, B.; Yang, M.; Zhukova, V.; Benvenuti, A. C.; Chatterjee, R. M.; Evans, A.; Finkel, A.; Gude, A.; Hansen, P.; Kalafut, S.; Kao, S. C.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Tambe, N.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bartek, R.; Bloom, K.; Bose, S.; Claes, D. R.; Dominguez, A.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Knowlton, D.; Kravchenko, I.; Malta Rodrigues, A.; Meier, F.; Monroy, J.; Siado, J. E.; Snow, G. R.; Stieger, B.; Alyari, M.; Dolen, J.; George, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Kaisen, J.; Kharchilava, A.; Kumar, A.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Baumgartel, D.; Chasco, M.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira De Lima, R.; Trocino, D.; Wang, R.-J.; Wood, D.; Bhattacharya, S.; Hahn, K. A.; Kubik, A.; Low, J. F.; Mucia, N.; Odell, N.; Pollack, B.; Schmitt, M. H.; Sung, K.; Trovato, M.; Velasco, M.; Dev, N.; Hildreth, M.; Hurtado Anampa, K.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Smith, G.; Taroni, S.; Valls, N.; Wayne, M.; Wolf, M.; Woodard, A.; Alimena, J.; Antonelli, L.; Brinson, J.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Francis, B.; Hart, A.; Hill, C.; Hughes, R.; Ji, W.; Liu, B.; Luo, W.; Puigh, D.; Winer, B. L.; Wulsin, H. W.; Cooperstein, S.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Luo, J.; Marlow, D.; Medvedeva, T.; Mooney, M.; Olsen, J.; Palmer, C.; Piroué, P.; Stickland, D.; Tully, C.; Zuranski, A.; Malik, S.; Barker, A.; Barnes, V. E.; Benedetti, D.; Folgueras, S.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, A. W.; Jung, K.; Miller, D. H.; Neumeister, N.; Radburn-Smith, B. C.; Shi, X.; Sun, J.; Svyatkovskiy, A.; Wang, F.; Xie, W.; Xu, L.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Redjimi, R.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Betchart, B.; Bodek, A.; de Barbaro, P.; Demina, R.; Duh, Y. t.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Tan, P.; Verzetti, M.; Mesropian, C.; Chou, J. P.; Contreras-Campana, E.; Gershtein, Y.; Gómez Espinosa, T. A.; Halkiadakis, E.; Heindl, M.; Hidas, D.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Kyriacou, S.; Lath, A.; Nash, K.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Foerster, M.; Heideman, J.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Celik, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Juska, E.; Kamon, T.; Krutelyov, V.; Mueller, R.; Pakhotin, Y.; Patel, R.; Perloff, A.; Perniè, L.; Rathjens, D.; Rose, A.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Cowden, C.; Damgov, J.; Dragoiu, C.; Dudero, P. R.; Faulkner, J.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Undleeb, S.; Volobouev, I.; Wang, Z.; Delannoy, A. G.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Melo, A.; Ni, H.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Barria, P.; Cox, B.; Goodell, J.; Hirosky, R.; Ledovskoy, A.; Li, H.; Neu, C.; Sinthuprasith, T.; Sun, X.; Wang, Y.; Wolfe, E.; Xia, F.; Clarke, C.; Harr, R.; Karchin, P. E.; Lamichhane, P.; Sturdy, J.; Belknap, D. A.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Ojalvo, I.; Perry, T.; Pierro, G. A.; Polese, G.; Ruggles, T.; Savin, A.; Sharma, A.; Smith, N.; Smith, W. H.; Taylor, D.; Woods, N.
2017-03-01
A measurement of the double-differential inclusive jet cross section as a function of the jet transverse momentum p T and the absolute jet rapidity | y| is presented. Data from LHC proton-proton collisions at √{s}=8 TeV, corresponding to an integrated luminosity of 19.7 fb-1, have been collected with the CMS detector. Jets are reconstructed using the anti- k T clustering algorithm with a size parameter of 0.7 in a phase space region covering jet p T from 74 GeV up to 2.5 TeV and jet absolute rapidity up to | y| = 3.0. The low- p T jet range between 21 and 74 GeV is also studied up to | y| = 4.7, using a dedicated data sample corresponding to an integrated luminosity of 5.6 pb-1. The measured jet cross section is corrected for detector effects and compared with the predictions from perturbative QCD at next-to-leading order (NLO) using various sets of parton distribution functions (PDF). Cross section ratios to the corresponding measurements performed at 2.76 and 7 TeV are presented. From the measured double-differential jet cross section, the value of the strong coupling constant evaluated at the Z mass is α S( M Z) = 0.1164 - 0.0043 + 0.0060 , where the errors include the PDF, scale, nonperturbative effects and experimental uncertainties, using the CT10 NLO PDFs. Improved constraints on PDFs based on the inclusive jet cross section measurement are presented. [Figure not available: see fulltext.
Measuring and Validating Neutron Capture Cross Sections Using a Lead Slowing-Down Spectrometer
NASA Astrophysics Data System (ADS)
Thompson, Nicholas
Accurate nuclear data is essential for the modeling, design, and operation of nuclear systems. In this work, the Rensselaer Polytechnic Institute (RPI) Lead Slowing-Down Spectrometer (LSDS) at the Gaerttner Linear Accelerator Center (LINAC) was used to measure neutron capture cross sections and validate capture cross sections in cross section libraries. The RPI LINAC was used to create a fast burst of neutrons in the center of the LSDS, a large cube of high purity lead. A sample and YAP:Ce scintillator were placed in the LSDS, and as neutrons lost energy through scattering interactions with the lead, the scintillator detected capture gammas resulting from neutron capture events in the sample. Samples of silver, gold, cobalt, iron, indium, molybdenum, niobium, nickel, tin, tantalum, and zirconium were measured. Data was collected as a function of time after neutron pulse, or slowing-down time, which is correlated to average neutron energy. An analog and a digital data acquisition system collected data simultaneously, allowing for collection of pulse shape information as well as timing. Collection of digital data allowed for pulse shape analysis after the experiment. This data was then analyzed and compared to Monte Carlo simulations to validate the accuracy of neutron capture cross section libraries. These measurements represent the first time that neutron capture cross sections have been measured using an LSDS in the United States, and the first time tools such as coincidence measurements and pulse height weighting have been applied to measurements of neutron capture cross sections using an LSDS. Significant differences between measurement results and simulation results were found in multiple materials, and some errors in nuclear data libraries have already been identified due to these measurements.
NASA Astrophysics Data System (ADS)
Castillo, Carlos; Pérez, Rafael
2017-04-01
The assessment of gully erosion volumes is essential for the quantification of soil losses derived from this relevant degradation process. Traditionally, 2D and 3D approaches has been applied for this purpose (Casalí et al., 2006). Although innovative 3D approaches have recently been proposed for gully volume quantification, a renewed interest can be found in literature regarding the useful information that cross-section analysis still provides in gully erosion research. Moreover, the application of methods based on 2D approaches can be the most cost-effective approach in many situations such as preliminary studies with low accuracy requirements or surveys under time or budget constraints. The main aim of this work is to examine the key factors controlling volume error variability in 2D gully assessment by means of a stochastic experiment involving a Monte Carlo analysis over synthetic gully profiles in order to 1) contribute to a better understanding of the drivers and magnitude of gully erosion 2D-surveys uncertainty and 2) provide guidelines for optimal survey designs. Owing to the stochastic properties of error generation in 2D volume assessment, a statistical approach was followed to generate a large and significant set of gully reach configurations to evaluate quantitatively the influence of the main factors controlling the uncertainty of the volume assessment. For this purpose, a simulation algorithm in Matlab® code was written, involving the following stages: - Generation of synthetic gully area profiles with different degrees of complexity (characterized by the cross-section variability) - Simulation of field measurements characterised by a survey intensity and the precision of the measurement method - Quantification of the volume error uncertainty as a function of the key factors In this communication we will present the relationships between volume error and the studied factors and propose guidelines for 2D field surveys based on the minimal survey densities required to achieve a certain accuracy given the cross-sectional variability of a gully and the measurement method applied. References Casali, J., Loizu, J., Campo, M.A., De Santisteban, L.M., Alvarez-Mozos, J., 2006. Accuracy of methods for field assessment of rill and ephemeral gully erosion. Catena 67, 128-138. doi:10.1016/j.catena.2006.03.005
Foveal Curvature and Asymmetry Assessed Using Optical Coherence Tomography.
VanNasdale, Dean A; Eilerman, Amanda; Zimmerman, Aaron; Lai, Nicky; Ramsey, Keith; Sinnott, Loraine T
2017-06-01
The aims of this study were to use cross-sectional optical coherence tomography imaging and custom curve fitting software to evaluate and model the foveal curvature as a spherical surface and to compare the radius of curvature in the horizontal and vertical meridians and test the sensitivity of this technique to anticipated meridional differences. Six 30-degree foveal-centered radial optical coherence tomography cross-section scans were acquired in the right eye of 20 clinically normal subjects. Cross sections were manually segmented, and custom curve fitting software was used to determine foveal pit radius of curvature using the central 500, 1000, and 1500 μm of the foveal contour. Radius of curvature was compared across different fitting distances. Root mean square error was used to determine goodness of fit. The radius of curvature was compared between the horizontal and vertical meridians for each fitting distance. There radius of curvature was significantly different when comparing each of the three fitting distances (P < .01 for each comparison). The average radii of curvature were 970 μm (95% confidence interval [CI], 913 to 1028 μm), 1386 μm (95% CI, 1339 to 1439 μm), and 2121 μm (95% CI, 2066 to 2183) for the 500-, 1000-, and 1500-μm fitting distances, respectively. Root mean square error was also significantly different when comparing each fitting distance (P < .01 for each comparison). The average root mean square errors were 2.48 μm (95% CI, 2.41 to 2.53 μm), 6.22 μm (95% CI, 5.77 to 6.60 μm), and 13.82 μm (95% CI, 12.93 to 14.58 μm) for the 500-, 1000-, and 1500-μm fitting distances, respectively. The radius of curvature between the horizontal and vertical meridian radii was statistically different only in the 1000- and 1500-μm fitting distances (P < .01 for each), with the horizontal meridian being flatter than the vertical. The foveal contour can be modeled as a sphere with low curve fitting error over a limited distance and capable of detecting subtle foveal contour differences between meridians.
Observation of e+e-→ω χc 1 ,2 near √{s }=4.42 and 4.6 GeV
NASA Astrophysics Data System (ADS)
Ablikim, M.; Achasov, M. N.; Ai, X. C.; Albayrak, O.; Albrecht, M.; Ambrose, D. J.; Amoroso, A.; An, F. F.; An, Q.; Bai, J. Z.; Baldini Ferroli, R.; Ban, Y.; Bennett, D. W.; Bennett, J. V.; Bertani, M.; Bettoni, D.; Bian, J. M.; Bianchi, F.; Boger, E.; Boyko, I.; Briere, R. A.; Cai, H.; Cai, X.; Cakir, O.; Calcaterra, A.; Cao, G. F.; Cetin, S. A.; Chang, J. F.; Chelkov, G.; Chen, G.; Chen, H. S.; Chen, H. Y.; Chen, J. C.; Chen, M. L.; Chen, S. J.; Chen, X.; Chen, X. R.; Chen, Y. B.; Cheng, H. P.; Chu, X. K.; Cibinetto, G.; Dai, H. L.; Dai, J. P.; Dbeyssi, A.; Dedovich, D.; Deng, Z. Y.; Denig, A.; Denysenko, I.; Destefanis, M.; de Mori, F.; Ding, Y.; Dong, C.; Dong, J.; Dong, L. Y.; Dong, M. Y.; Dou, Z. L.; Du, S. X.; Duan, P. F.; Eren, E. E.; Fan, J. Z.; Fang, J.; Fang, S. S.; Fang, X.; Fang, Y.; Farinelli, R.; Fava, L.; Fedorov, O.; Feldbauer, F.; Felici, G.; Feng, C. Q.; Fioravanti, E.; Fritsch, M.; Fu, C. D.; Gao, Q.; Gao, X. L.; Gao, X. Y.; Gao, Y.; Gao, Z.; Garzia, I.; Goetzen, K.; Gong, L.; Gong, W. X.; Gradl, W.; Greco, M.; Gu, M. H.; Gu, Y. T.; Guan, Y. H.; Guo, A. Q.; Guo, L. B.; Guo, Y.; Guo, Y. P.; Haddadi, Z.; Hafner, A.; Han, S.; Hao, X. Q.; Harris, F. A.; He, K. L.; Held, T.; Heng, Y. K.; Hou, Z. L.; Hu, C.; Hu, H. M.; Hu, J. F.; Hu, T.; Hu, Y.; Huang, G. S.; Huang, J. S.; Huang, X. T.; Huang, Y.; Hussain, T.; Ji, Q.; Ji, Q. P.; Ji, X. B.; Ji, X. L.; Jiang, L. W.; Jiang, X. S.; Jiang, X. Y.; Jiao, J. B.; Jiao, Z.; Jin, D. P.; Jin, S.; Johansson, T.; Julin, A.; Kalantar-Nayestanaki, N.; Kang, X. L.; Kang, X. S.; Kavatsyuk, M.; Ke, B. C.; Kiese, P.; Kliemt, R.; Kloss, B.; Kolcu, O. B.; Kopf, B.; Kornicer, M.; Kuehn, W.; Kupsc, A.; Lange, J. S.; Lara, M.; Larin, P.; Leng, C.; Li, C.; Li, C. H.; Li, Cheng; Li, D. M.; Li, F.; Li, F. Y.; Li, G.; Li, H. B.; Li, J. C.; Li, Jin; Li, K.; Li, K.; Li, Lei; Li, P. R.; Li, Q. Y.; Li, T.; Li, W. D.; Li, W. G.; Li, X. L.; Li, X. M.; Li, X. N.; Li, X. Q.; Li, Z. B.; Liang, H.; Liang, Y. F.; Liang, Y. T.; Liao, G. R.; Lin, D. X.; Liu, B. J.; Liu, C. X.; Liu, D.; Liu, F. H.; Liu, Fang; Liu, Feng; Liu, H. B.; Liu, H. H.; Liu, H. H.; Liu, H. M.; Liu, J.; Liu, J. B.; Liu, J. P.; Liu, J. Y.; Liu, K.; Liu, K. Y.; Liu, L. D.; Liu, P. L.; Liu, Q.; Liu, S. B.; Liu, X.; Liu, Y. B.; Liu, Z. A.; Liu, Zhiqing; Loehner, H.; Lou, X. C.; Lu, H. J.; Lu, J. G.; Lu, Y.; Lu, Y. P.; Luo, C. L.; Luo, M. X.; Luo, T.; Luo, X. L.; Lyu, X. R.; Ma, F. C.; Ma, H. L.; Ma, L. L.; Ma, Q. M.; Ma, T.; Ma, X. N.; Ma, X. Y.; Ma, Y. M.; Maas, F. E.; Maggiora, M.; Mao, Y. J.; Mao, Z. P.; Marcello, S.; Messchendorp, J. G.; Min, J.; Mitchell, R. E.; Mo, X. H.; Mo, Y. J.; Morales Morales, C.; Muchnoi, N. Yu.; Muramatsu, H.; Nefedov, Y.; Nerling, F.; Nikolaev, I. B.; Ning, Z.; Nisar, S.; Niu, S. L.; Niu, X. Y.; Olsen, S. L.; Ouyang, Q.; Pacetti, S.; Pan, Y.; Patteri, P.; Pelizaeus, M.; Peng, H. P.; Peters, K.; Pettersson, J.; Ping, J. L.; Ping, R. G.; Poling, R.; Prasad, V.; Qi, H. R.; Qi, M.; Qian, S.; Qiao, C. F.; Qin, L. Q.; Qin, N.; Qin, X. S.; Qin, Z. H.; Qiu, J. F.; Rashid, K. H.; Redmer, C. F.; Ripka, M.; Rong, G.; Rosner, Ch.; Ruan, X. D.; Santoro, V.; Sarantsev, A.; Savrié, M.; Schoenning, K.; Schumann, S.; Shan, W.; Shao, M.; Shen, C. P.; Shen, P. X.; Shen, X. Y.; Sheng, H. Y.; Song, W. M.; Song, X. Y.; Sosio, S.; Spataro, S.; Sun, G. X.; Sun, J. F.; Sun, S. S.; Sun, Y. J.; Sun, Y. Z.; Sun, Z. J.; Sun, Z. T.; Tang, C. J.; Tang, X.; Tapan, I.; Thorndike, E. H.; Tiemens, M.; Ullrich, M.; Uman, I.; Varner, G. S.; Wang, B.; Wang, B. L.; Wang, D.; Wang, D. Y.; Wang, K.; Wang, L. L.; Wang, L. S.; Wang, M.; Wang, P.; Wang, P. L.; Wang, S. G.; Wang, W.; Wang, W. P.; Wang, X. F.; Wang, Y. D.; Wang, Y. F.; Wang, Y. Q.; Wang, Z.; Wang, Z. G.; Wang, Z. H.; Wang, Z. Y.; Weber, T.; Wei, D. H.; Wei, J. B.; Weidenkaff, P.; Wen, S. P.; Wiedner, U.; Wolke, M.; Wu, L. H.; Wu, Z.; Xia, L.; Xia, L. G.; Xia, Y.; Xiao, D.; Xiao, H.; Xiao, Z. J.; Xie, Y. G.; Xiu, Q. L.; Xu, G. F.; Xu, L.; Xu, Q. J.; Xu, Q. N.; Xu, X. P.; Yan, L.; Yan, W. B.; Yan, W. C.; Yan, Y. H.; Yang, H. J.; Yang, H. X.; Yang, L.; Yang, Y. X.; Ye, M.; Ye, M. H.; Yin, J. H.; Yu, B. X.; Yu, C. X.; Yu, J. S.; Yuan, C. Z.; Yuan, W. L.; Yuan, Y.; Yuncu, A.; Zafar, A. A.; Zallo, A.; Zeng, Y.; Zeng, Z.; Zhang, B. X.; Zhang, B. Y.; Zhang, C.; Zhang, C. C.; Zhang, D. H.; Zhang, H. H.; Zhang, H. Y.; Zhang, J. J.; Zhang, J. L.; Zhang, J. Q.; Zhang, J. W.; Zhang, J. Y.; Zhang, J. Z.; Zhang, K.; Zhang, L.; Zhang, X. Y.; Zhang, Y.; Zhang, Y. H.; Zhang, Y. N.; Zhang, Y. T.; Zhang, Yu; Zhang, Z. H.; Zhang, Z. P.; Zhang, Z. Y.; Zhao, G.; Zhao, J. W.; Zhao, J. Y.; Zhao, J. Z.; Zhao, Lei; Zhao, Ling; Zhao, M. G.; Zhao, Q.; Zhao, Q. W.; Zhao, S. J.; Zhao, T. C.; Zhao, Y. B.; Zhao, Z. G.; Zhemchugov, A.; Zheng, B.; Zheng, J. P.; Zheng, W. J.; Zheng, Y. H.; Zhong, B.; Zhou, L.; Zhou, X.; Zhou, X. K.; Zhou, X. R.; Zhou, X. Y.; Zhu, K.; Zhu, K. J.; Zhu, S.; Zhu, S. H.; Zhu, X. L.; Zhu, Y. C.; Zhu, Y. S.; Zhu, Z. A.; Zhuang, J.; Zotti, L.; Zou, B. S.; Zou, J. H.; Besiii Collaboration
2016-01-01
Based on data samples collected with the BESIII detector operating at the BEPCII storage ring at center-of-mass energies √{s }>4.4 GeV , the processes e+e-→ω χc 1 ,2 are observed for the first time. With an integrated luminosity of 1074 pb-1 near √{s }=4.42 GeV , a significant ω χc 2 signal is found, and the cross section is measured to be (20.9 ±3.2 ±2.5 ) pb . With 567 pb-1 near √{s }=4.6 GeV , a clear ω χc 1 signal is seen, and the cross section is measured to be (9.5 ±2.1 ±1.3 ) pb , while evidence is found for an ω χc 2 signal. The first errors are statistical, and the second are systematic. Due to low luminosity or low cross section at other energies, no significant signals are observed. In the ω χc 2 cross section, an enhancement is seen around √{s }=4.42 GeV . Fitting the cross section with a coherent sum of the ψ (4415 ) Breit-Wigner function and a phase-space term, the branching fraction B (ψ (4415 )→ω χc 2) is obtained to be of the order of 1 0-3.
Re-measurement of the 33S(α ,p )36Cl cross section for early solar system nuclide enrichment
NASA Astrophysics Data System (ADS)
Anderson, Tyler; Skulski, Michael; Clark, Adam; Nelson, Austin; Ostdiek, Karen; Collon, Philippe; Chmiel, Greg; Woodruff, Tom; Caffee, Marc
2017-07-01
Short-lived radionuclides (SLRs) with half-lives less than 100 Myr are known to have existed around the time of the formation of the solar system around 4.5 billion years ago. Understanding the production sources for SLRs is important for improving our understanding of processes taking place just after solar system formation as well as their timescales. Early solar system models rely heavily on calculations from nuclear theory due to a lack of experimental data for the nuclear reactions taking place. In 2013, Bowers et al. measured 36Cl production cross sections via the 33S(α ,p ) reaction and reported cross sections that were systematically higher than predicted by Hauser-Feshbach codes. Soon after, a paper by Peter Mohr highlighted the challenges the new data would pose to current nuclear theory if verified. The 33S(α ,p )36Cl reaction was re-measured at five energies between 0.78 MeV/nucleon and 1.52 MeV/nucleon, in the same range as measured by Bowers et al., and found systematically lower cross sections than originally reported, with the new results in good agreement with the Hauser-Feshbach code talys. Loss of Cl carrier in chemical extraction and errors in determination of reaction energy ranges are both possible explanations for artificially inflated cross sections measured in the previous work.
Cross-sectional structural parameters from densitometry
NASA Technical Reports Server (NTRS)
Cleek, Tammy M.; Whalen, Robert T.
2002-01-01
Bone densitometry has previously been used to obtain cross-sectional properties of bone from a single X-ray projection across the bone width. Using three unique projections, we have extended the method to obtain the principal area moments of inertia and orientations of the principal axes at each scan cross-section along the length of the scan. Various aluminum phantoms were used to examine scanner characteristics to develop the highest accuracy possible for in vitro non-invasive analysis of cross-sectional properties. Factors considered included X-ray photon energy, initial scan orientation, the angle spanned by the three scans (included angle), and I(min)/I(max) ratios. Principal moments of inertia were accurate to within +/-3.1% and principal angles were within +/-1 degrees of the expected value for phantoms scanned with included angles of 60 degrees and 90 degrees at the higher X-ray photon energy (140 kVp). Low standard deviations in the error (0.68-1.84%) also indicate high precision of calculated measurements with these included angles. Accuracy and precision decreased slightly when the included angle was reduced to 30 degrees. The method was then successfully applied to a pair of excised cadaveric tibiae. The accuracy and insensitivity of the algorithms to cross-sectional shape and changing isotropy (I(min)/I(max)) values when various included angles are used make this technique viable for future in vivo studies.
NASA Astrophysics Data System (ADS)
Divay, C.; Colin, J.; Cussol, D.; Finck, Ch.; Karakaya, Y.; Labalme, M.; Rousseau, M.; Salvador, S.; Vanstalle, M.
2017-04-01
During a carbon therapy treatment, the beam undergoes inelastic nuclear reactions leading to the production of secondary fragments. These nuclear interactions tend to delocate a part of the dose into healthy tissues and create a mixed radiation field. In order to accurately estimate the dose deposited into the tissues, the production rate of these fragments all along the beam path have to be taken into account. But the double differential carbon fragmentation cross sections are not well known in the energy range needed for a treatment (up to 400 MeV/nucleon). Therefore, a series of experiments aiming to measure the double differential fragmentation cross sections of carbon on thin targets of medical interest has been started by our collaboration. In March 2015 we performed an experiment to study the fragmentation of a 50 MeV/nucleon 12C beam on thin targets at GANIL. During this experiment, energy and angular cross-section distributions on H, C, O, Al, and natTi have been measured. The experimental set-up will be detailed as well as the systematic error study and all the experimental results will be presented.
Determination of vessel cross-sectional area by thresholding in Radon space
Gao, Yu-Rong; Drew, Patrick J
2014-01-01
The cross-sectional area of a blood vessel determines its resistance, and thus is a regulator of local blood flow. However, the cross-sections of penetrating vessels in the cortex can be non-circular, and dilation and constriction can change the shape of the vessels. We show that observed vessel shape changes can introduce large errors in flux calculations when using a single diameter measurement. Because of these shape changes, typical diameter measurement approaches, such as the full-width at half-maximum (FWHM) that depend on a single diameter axis will generate erroneous results, especially when calculating flux. Here, we present an automated method—thresholding in Radon space (TiRS)—for determining the cross-sectional area of a convex object, such as a penetrating vessel observed with two-photon laser scanning microscopy (2PLSM). The thresholded image is transformed back to image space and contiguous pixels are segmented. The TiRS method is analogous to taking the FWHM across multiple axes and is more robust to noise and shape changes than FWHM and thresholding methods. We demonstrate the superior precision of the TiRS method with in vivo 2PLSM measurements of vessel diameter. PMID:24736890
3D Measurement of Anatomical Cross-sections of Foot while Walking
NASA Astrophysics Data System (ADS)
Kimura, Makoto; Mochimaru, Masaaki; Kanade, Takeo
Recently, techniques for measuring and modeling of human body are taking attention, because human models are useful for ergonomic design in manufacturing. We aim to measure accurate shape of human foot that will be useful for the design of shoes. For such purpose, shape measurement of foot in motion is obviously important, because foot shape in the shoe is deformed while walking or running. In this paper, we propose a method to measure anatomical cross-sections of foot while walking. No one had ever measured dynamic shape of anatomical cross-sections, though they are very basic and popular in the field of biomechanics. Our proposed method is based on multi-view stereo method. The target cross-sections are painted in individual colors (red, green, yellow and blue), and the proposed method utilizes the characteristic of target shape in the camera captured images. Several nonlinear conditions are introduced in the process to find the consistent correspondence in all images. Our desired accuracy is less than 1mm error, which is similar to the existing 3D scanners for static foot measurement. In our experiments, the proposed method achieved the desired accuracy.
Nour-Eldein, Hebatallah
2016-01-01
With limited statistical knowledge of most physicians it is not uncommon to find statistical errors in research articles. To determine the statistical methods and to assess the statistical errors in family medicine (FM) research articles that were published between 2010 and 2014. This was a cross-sectional study. All 66 FM research articles that were published over 5 years by FM authors with affiliation to Suez Canal University were screened by the researcher between May and August 2015. Types and frequencies of statistical methods were reviewed in all 66 FM articles. All 60 articles with identified inferential statistics were examined for statistical errors and deficiencies. A comprehensive 58-item checklist based on statistical guidelines was used to evaluate the statistical quality of FM articles. Inferential methods were recorded in 62/66 (93.9%) of FM articles. Advanced analyses were used in 29/66 (43.9%). Contingency tables 38/66 (57.6%), regression (logistic, linear) 26/66 (39.4%), and t-test 17/66 (25.8%) were the most commonly used inferential tests. Within 60 FM articles with identified inferential statistics, no prior sample size 19/60 (31.7%), application of wrong statistical tests 17/60 (28.3%), incomplete documentation of statistics 59/60 (98.3%), reporting P value without test statistics 32/60 (53.3%), no reporting confidence interval with effect size measures 12/60 (20.0%), use of mean (standard deviation) to describe ordinal/nonnormal data 8/60 (13.3%), and errors related to interpretation were mainly for conclusions without support by the study data 5/60 (8.3%). Inferential statistics were used in the majority of FM articles. Data analysis and reporting statistics are areas for improvement in FM research articles.
Nour-Eldein, Hebatallah
2016-01-01
Background: With limited statistical knowledge of most physicians it is not uncommon to find statistical errors in research articles. Objectives: To determine the statistical methods and to assess the statistical errors in family medicine (FM) research articles that were published between 2010 and 2014. Methods: This was a cross-sectional study. All 66 FM research articles that were published over 5 years by FM authors with affiliation to Suez Canal University were screened by the researcher between May and August 2015. Types and frequencies of statistical methods were reviewed in all 66 FM articles. All 60 articles with identified inferential statistics were examined for statistical errors and deficiencies. A comprehensive 58-item checklist based on statistical guidelines was used to evaluate the statistical quality of FM articles. Results: Inferential methods were recorded in 62/66 (93.9%) of FM articles. Advanced analyses were used in 29/66 (43.9%). Contingency tables 38/66 (57.6%), regression (logistic, linear) 26/66 (39.4%), and t-test 17/66 (25.8%) were the most commonly used inferential tests. Within 60 FM articles with identified inferential statistics, no prior sample size 19/60 (31.7%), application of wrong statistical tests 17/60 (28.3%), incomplete documentation of statistics 59/60 (98.3%), reporting P value without test statistics 32/60 (53.3%), no reporting confidence interval with effect size measures 12/60 (20.0%), use of mean (standard deviation) to describe ordinal/nonnormal data 8/60 (13.3%), and errors related to interpretation were mainly for conclusions without support by the study data 5/60 (8.3%). Conclusion: Inferential statistics were used in the majority of FM articles. Data analysis and reporting statistics are areas for improvement in FM research articles. PMID:27453839
Vanmechelen, Inti M; Shortland, Adam P; Noble, Jonathan J
2018-01-01
Deficits in muscle volume may be a significant contributor to physical disability in young people with cerebral palsy. However, 3D measurements of muscle volume using MRI or 3D ultrasound may be difficult to make routinely in the clinic. We wished to establish whether accurate estimates of muscle volume could be made from a combination of anatomical cross-sectional area and length measurements in samples of typically developing young people and young people with bilateral cerebral palsy. Lower limb MRI scans were obtained from the lower limbs of 21 individuals with cerebral palsy (14.7±3years, 17 male) and 23 typically developing individuals (16.8±3.3years, 16 male). The volume, length and anatomical cross-sectional area were estimated from six muscles of the left lower limb. Analysis of Covariance demonstrated that the relationship between the length*cross-sectional area and volume was not significantly different depending on the subject group. Linear regression analysis demonstrated that the product of anatomical cross-sectional area and length bore a strong and significant relationship to the measured muscle volume (R 2 values between 0.955 and 0.988) with low standard error of the estimates of 4.8 to 8.9%. This study demonstrates that muscle volume may be estimated accurately in typically developing individuals and individuals with cerebral palsy by a combination of anatomical cross-sectional area and muscle length. 2D ultrasound may be a convenient method of making these measurements routinely in the clinic. Copyright © 2017 Elsevier Ltd. All rights reserved.
SEU System Analysis: Not Just the Sum of All Parts
NASA Technical Reports Server (NTRS)
Berg, Melanie D.; Label, Kenneth
2014-01-01
Single event upset (SEU) analysis of complex systems is challenging. Currently, system SEU analysis is performed by component level partitioning and then either: the most dominant SEU cross-sections (SEUs) are used in system error rate calculations; or the partition SEUs are summed to eventually obtain a system error rate. In many cases, system error rates are overestimated because these methods generally overlook system level derating factors. The problem with overestimating is that it can cause overdesign and consequently negatively affect the following: cost, schedule, functionality, and validation/verification. The scope of this presentation is to discuss the risks involved with our current scheme of SEU analysis for complex systems; and to provide alternative methods for improvement.
Pattern of refractive errors among patients at a tertiary hospital in Kathmandu.
Rizyal, A; Ghising, R; Shrestha, R K; Kansakar, I
2011-09-01
A hospital based cross sectional study was carried out to determine the pattern of refractive errors among patients attending the out patient department, Department of Ophthalmology, Nepal Medical College Teaching Hospital. A total of 1100 patients were evaluated, (male 43.67%; female 56.33%). Simple myopic astigmatism was the most prevalent type of refractive error accounting for 27.18% followed by simple myopia (21.66%) and compound myopic astigmatism (19.48%). Simple hypermetropia (15.03%) and mixed astigmatism (4.3%) were also noted. Simple myopia was prevalent among the younger age group in the first to third decades, whereas hypermetropia was seen in the older patients in the third to fifth decades.
NASA Astrophysics Data System (ADS)
Lozano, A. I.; Oller, J. C.; Krupa, K.; Ferreira da Silva, F.; Limão-Vieira, P.; Blanco, F.; Muñoz, A.; Colmenares, R.; García, G.
2018-06-01
A novel experimental setup has been implemented to provide accurate electron scattering cross sections from molecules at low and intermediate impact energies (1-300 eV) by measuring the attenuation of a magnetically confined linear electron beam from a molecular target. High-resolution electron energy is achieved through confinement in a magnetic gas trap where electrons are cooled by successive collisions with N2. Additionally, we developed and present a method to correct systematic errors arising from energy and angular resolution limitations. The accuracy of the entire measurement procedure is validated by comparing the N2 total scattering cross section in the considered energy range with benchmark values available in the literature.
Dinnsen, Daniel A.; Dow, Michael C.; Gierut, Judith A.; Morrisette, Michele L.; Green, Christopher R.
2013-01-01
This paper examines a range of predicted versus attested error patterns involving coronal fricatives (e.g. [s, z, θ, ð]) as targets and repairs in the early sound systems of monolingual English-acquiring children. Typological results are reported from a cross-sectional study of 234 children with phonological delays (ages 3 years; 0 months to 7;9). Our analyses revealed different instantiations of a putative developmental conspiracy within and across children. Supplemental longitudinal evidence is also presented that replicates the cross-sectional results, offering further insight into the life-cycle of the conspiracy. Several of the observed typological anomalies are argued to follow from a modified version of Optimality Theory with Candidate Chains (McCarthy, 2007). PMID:24790247
Anomalous annealing of floating gate errors due to heavy ion irradiation
NASA Astrophysics Data System (ADS)
Yin, Yanan; Liu, Jie; Sun, Youmei; Hou, Mingdong; Liu, Tianqi; Ye, Bing; Ji, Qinggang; Luo, Jie; Zhao, Peixiong
2018-03-01
Using the heavy ions provided by the Heavy Ion Research Facility in Lanzhou (HIRFL), the annealing of heavy-ion induced floating gate (FG) errors in 34 nm and 25 nm NAND Flash memories has been studied. The single event upset (SEU) cross section of FG and the evolution of the errors after irradiation depending on the ion linear energy transfer (LET) values, data pattern and feature size of the device are presented. Different rates of annealing for different ion LET and different pattern are observed in 34 nm and 25 nm memories. The variation of the percentage of different error patterns in 34 nm and 25 nm memories with annealing time shows that the annealing of FG errors induced by heavy-ion in memories will mainly take place in the cells directly hit under low LET ion exposure and other cells affected by heavy ions when the ion LET is higher. The influence of Multiple Cell Upsets (MCUs) on the annealing of FG errors is analyzed. MCUs with high error multiplicity which account for the majority of the errors can induce a large percentage of annealed errors.
Deterministic Modeling of the High Temperature Test Reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ortensi, J.; Cogliati, J. J.; Pope, M. A.
2010-06-01
Idaho National Laboratory (INL) is tasked with the development of reactor physics analysis capability of the Next Generation Nuclear Power (NGNP) project. In order to examine INL’s current prismatic reactor deterministic analysis tools, the project is conducting a benchmark exercise based on modeling the High Temperature Test Reactor (HTTR). This exercise entails the development of a model for the initial criticality, a 19 column thin annular core, and the fully loaded core critical condition with 30 columns. Special emphasis is devoted to the annular core modeling, which shares more characteristics with the NGNP base design. The DRAGON code is usedmore » in this study because it offers significant ease and versatility in modeling prismatic designs. Despite some geometric limitations, the code performs quite well compared to other lattice physics codes. DRAGON can generate transport solutions via collision probability (CP), method of characteristics (MOC), and discrete ordinates (Sn). A fine group cross section library based on the SHEM 281 energy structure is used in the DRAGON calculations. HEXPEDITE is the hexagonal z full core solver used in this study and is based on the Green’s Function solution of the transverse integrated equations. In addition, two Monte Carlo (MC) based codes, MCNP5 and PSG2/SERPENT, provide benchmarking capability for the DRAGON and the nodal diffusion solver codes. The results from this study show a consistent bias of 2–3% for the core multiplication factor. This systematic error has also been observed in other HTTR benchmark efforts and is well documented in the literature. The ENDF/B VII graphite and U235 cross sections appear to be the main source of the error. The isothermal temperature coefficients calculated with the fully loaded core configuration agree well with other benchmark participants but are 40% higher than the experimental values. This discrepancy with the measurement stems from the fact that during the experiments the control rods were adjusted to maintain criticality, whereas in the model, the rod positions were fixed. In addition, this work includes a brief study of a cross section generation approach that seeks to decouple the domain in order to account for neighbor effects. This spectral interpenetration is a dominant effect in annular HTR physics. This analysis methodology should be further explored in order to reduce the error that is systematically propagated in the traditional generation of cross sections.« less
On the Interaction of Velar Fronting and Labial Harmony
ERIC Educational Resources Information Center
Dinnsen, Daniel A.; Green, Christopher R.; Morrisette, Michele L.; Gierut, Judith A.
2011-01-01
This article documents the typological occurrence and interactions of two seemingly independent error patterns, namely Velar Fronting and Labial Harmony, in a cross-sectional investigation of the sound systems of 235 children with phonological delays (ages 3;0 to 7;9). The results revealed that the occurrence of Labial Harmony depends on the…
ERIC Educational Resources Information Center
Achenbach, Thomas M.
2011-01-01
The special section articles demonstrate the importance of informant discrepancies. They also illustrate challenges posed by discrepancies, plus opportunities for advancing research and practice. This commentary addresses these cross-cutting issues: (a) Discrepancies affect many kinds of assessment besides ratings of children's problems. (b)…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rominsky, Mandy Kathleen
2009-01-01
This thesis presents the analysis of the double differential dijet mass cross section, measured at the D0 detector in Batavia, IL, using pmore » $$\\bar{p}$$ collisions at a center of mass energy of √s = 1.96 TeV. The dijet mass was calculated using the two highest p T jets in the event, with approximately 0.7 fb -1 of data collected between 2004 and 2005. The analysis was presented in bins of dijet mass (M JJ) and rapidity (y), and extends the measurement farther in M JJ and y than any previous measurement. Corrections due to detector effects were calculated using a Monte Carlo simulation and applied to data. The errors on the measurement consist of statistical and systematic errors, of which the Jet Energy Scale was the largest. The final result was compared to next-to-leading order theory and good agreement was found. These results may be used in the determination of the proton parton distribution functions and to set limits on new physics.« less
NASA Astrophysics Data System (ADS)
Fulkerson, David E.
2010-02-01
This paper describes a new methodology for characterizing the electrical behavior and soft error rate (SER) of CMOS and SiGe HBT integrated circuits that are struck by ions. A typical engineering design problem is to calculate the SER of a critical path that commonly includes several circuits such as an input buffer, several logic gates, logic storage, clock tree circuitry, and an output buffer. Using multiple 3D TCAD simulations to solve this problem is too costly and time-consuming for general engineering use. The new and simple methodology handles the problem with ease by simple SPICE simulations. The methodology accurately predicts the measured threshold linear energy transfer (LET) of a bulk CMOS SRAM. It solves for circuit currents and voltage spikes that are close to those predicted by expensive 3D TCAD simulations. It accurately predicts the measured event cross-section vs. LET curve of an experimental SiGe HBT flip-flop. The experimental cross section vs. frequency behavior and other subtle effects are also accurately predicted.
Prevalence of refraction errors and color blindness in heavy vehicle drivers.
Erdoğan, Haydar; Ozdemir, Levent; Arslan, Seher; Cetin, Ilhan; Ozeç, Ayşe Vural; Cetinkaya, Selma; Sümer, Haldun
2011-01-01
To investigate the frequency of eye disorders in heavy vehicle drivers. A cross-sectional type study was conducted between November 2004 and September 2006 in 200 driver and 200 non-driver persons. A complete ophthalmologic examination was performed, including visual acuity, and dilated examination of the posterior segment. We used the auto refractometer for determining refractive errors. According to eye examination results, the prevalence of the refractive error was 21.5% and 31.3% in study and control groups respectively (P<0.05). The most common type of refraction error in the study group was myopic astigmatism (8.3%) while in the control group simple myopia (12.8%). Prevalence of dyschromatopsia in the rivers, control group and total group was 2.2%, 2.8% and 2.6% respectively. A considerably high number of drivers are in lack of optimal visual acuity. Refraction errors in drivers may impair the traffic security.
NASA Astrophysics Data System (ADS)
Zhang, Kuiyuan; Umehara, Shigehiro; Yamaguchi, Junki; Furuta, Jun; Kobayashi, Kazutoshi
2016-08-01
This paper analyzes how body bias and BOX region thickness affect soft error rates in 65-nm SOTB (Silicon on Thin BOX) and 28-nm UTBB (Ultra Thin Body and BOX) FD-SOI processes. Soft errors are induced by alpha-particle and neutron irradiation and the results are then analyzed by Monte Carlo based simulation using PHITS-TCAD. The alpha-particle-induced single event upset (SEU) cross-section and neutron-induced soft error rate (SER) obtained by simulation are consistent with measurement results. We clarify that SERs decreased in response to an increase in the BOX thickness for SOTB while SERs in UTBB are independent of BOX thickness. We also discover SOTB develops a higher tolerance to soft errors when reverse body bias is applied while UTBB become more susceptible.
Prevalence of refraction errors and color blindness in heavy vehicle drivers
Erdoğan, Haydar; Özdemir, Levent; Arslan, Seher; Çetin, Ilhan; Özeç, Ayşe Vural; Çetinkaya, Selma; Sümer, Haldun
2011-01-01
AIM To investigate the frequency of eye disorders in heavy vehicle drivers. METHODS A cross-sectional type study was conducted between November 2004 and September 2006 in 200 driver and 200 non-driver persons. A complete ophthalmologic examination was performed, including visual acuity, and dilated examination of the posterior segment. We used the auto refractometer for determining refractive errors. RESULTS According to eye examination results, the prevalence of the refractive error was 21.5% and 31.3% in study and control groups respectively (P<0.05). The most common type of refraction error in the study group was myopic astigmatism (8.3%) while in the control group simple myopia (12.8%). Prevalence of dyschromatopsia in the rivers, control group and total group was 2.2%, 2.8% and 2.6% respectively. CONCLUSION A considerably high number of drivers are in lack of optimal visual acuity. Refraction errors in drivers may impair the traffic security. PMID:22553671
Study of DD Neutrons and their Transmission in Iron Spheres
NASA Astrophysics Data System (ADS)
Dhakal, Sushil
The Deuterium-Deuteron (DD) reaction has been used as a neutron source to study the transport of neutrons in natural iron. The scattering targets are used in the form of spheres and the neutron transmission measurement has been done at 7-MeV incident deuteron beam energy. The purpose of this study is to test the elastic and non-elastic neutron scattering cross sections for iron in the ENDF/B-VII data library, as some indications about the inaccuracy of those cross sections have been found from previous studies. The experiment has been carried out using the 4.5-MV tandem accelerator at Edwards Accelerator Laboratory at Ohio University, Athens, Ohio. The DD source reaction has been measured at 5- and 7-MeV deuteron beam energy. The D(d,n)3He monoenergetic reaction cross section has been measured from 0° to 135° at both 5- and 7-MeV beam energy and the D(d,np)D breakup reaction cross section has been measured up to 60° laboratory angles at 7-MeV beam energy. The target used is a deuterium gas cell of 3-cm length at approximately 2 atmosphere absolute pressure. The neutron energy is determined using the time of flight method. A NE213 liquid scintillation detector is used for neutron detection and the thick-target 27Al(d,n) reaction is used for the determination of neutron detector efficiency. The monoenergetic reaction cross section has been found to be in reasonable agreement with previous evaluations. The neutron transmission studies through iron spheres is done using two natural iron spheres with thicknesses of 3 and 8 cm. The DD source measurement (sphere-off) were repeated for the transmission studies and the neutron source was covered with the spheres for the transmission measurements. The experimental transmitted neutron spectrum is compared with the calculation done using Monte Carlo simulation code MCNP6.1 developed by Los Alamos National Laboratory. MCNP uses ENDF/B-VII.1 evaluated iron cross section for the simulation. The calculated and experimental neutron spectrum in time of flight has been compared at various laboratory angles from 0° to 150°. The calculated and experimental neutron time of flight spectra for neutron counts under the main peak (D(d,n)3He peak region) agree within the error bars for angles 90°, 135° and 150° for larger sphere (8-cm thickness) whereas they agree for all angles 0°, 15°, 30°, 45°, 90°, 135° and 150° for smaller sphere (3-cm thickness). However, the calculated and experimental neutron spectra show a difference of 12%, 11.80%, 16.85% and 19.67% in the main peak neutron counts for larger sphere at angles 0°, 15°, 30° and 45° respectively which can not be accounted for by the systematic uncertainty in our measurement (the 5% uncertainty in the target thickness and the 5% efficiency systematics are the main contributors). The sphere-off to on ratios for the calculation and the experiment also show a significant difference at those angles and this comparison is more robust as it avoids most of the systematic uncertainties including the efficiency. These differences likely come from the uncertainty in the ENDF cross section used. To test the ENDF cross section sensitivity, elastic cross section is decreased by 10% and inelastic cross section is increased by 14.78% in the energy range 7.2 to 11 MeV which corresponds to the energy range of the monoenergetic neutron peak for angles between 0° to 45°. This cross section modification keeps the total cross section constant on average in that energy range as the total in the library is assumed to be correct. This modification reduces the difference between the calculation and the experiment and brings it in agreement within the error bars. This result implies the possibility of underestimation of inelastic cross section in the above energy range and hence the overestimation of elastic cross section in the ENDF library.
2016-01-01
Collision cross section (CCS) measurement of lipids using traveling wave ion mobility-mass spectrometry (TWIM-MS) is of high interest to the lipidomics field. However, currently available calibrants for CCS measurement using TWIM are predominantly peptides that display quite different physical properties and gas-phase conformations from lipids, which could lead to large CCS calibration errors for lipids. Here we report the direct CCS measurement of a series of phosphatidylcholines (PCs) and phosphatidylethanolamines (PEs) in nitrogen using a drift tube ion mobility (DTIM) instrument and an evaluation of the accuracy and reproducibility of PCs and PEs as CCS calibrants for phospholipids against different classes of calibrants, including polyalanine (PolyAla), tetraalkylammonium salts (TAA), and hexakis(fluoroalkoxy)phosphazines (HFAP), in both positive and negative modes in TWIM-MS analysis. We demonstrate that structurally mismatched calibrants lead to larger errors in calibrated CCS values while the structurally matched calibrants, PCs and PEs, gave highly accurate and reproducible CCS values at different traveling wave parameters. Using the lipid calibrants, the majority of the CCS values of several classes of phospholipids measured by TWIM are within 2% error of the CCS values measured by DTIM. The development of phospholipid CCS calibrants will enable high-accuracy structural studies of lipids and add an additional level of validation in the assignment of identifications in untargeted lipidomics experiments. PMID:27321977
A one-dimensional model of flow in a junction of thin channels, including arterial trees
NASA Astrophysics Data System (ADS)
Kozlov, V. A.; Nazarov, S. A.
2017-08-01
We study a Stokes flow in a junction of thin channels (of diameter O(h)) for fixed flows of the fluid at the inlet cross-sections and fixed peripheral pressure at the outlet cross-sections. On the basis of the idea of the pressure drop matrix, apart from Neumann conditions (fixed flow) and Dirichlet conditions (fixed pressure) at the outer vertices, the ordinary one-dimensional Reynolds equations on the edges of the graph are equipped with transmission conditions containing a small parameter h at the inner vertices, which are transformed into the classical Kirchhoff conditions as h\\to+0. We establish that the pre-limit transmission conditions ensure an exponentially small error O(e-ρ/h), ρ>0, in the calculation of the three-dimensional solution, but the Kirchhoff conditions only give polynomially small error. For the arterial tree, under the assumption that the walls of the blood vessels are rigid, for every bifurcation node a ( 2×2)-pressure drop matrix appears, and its influence on the transmission conditions is taken into account by means of small variations of the lengths of the graph and by introducing effective lengths of the one-dimensional description of blood vessels whilst keeping the Kirchhoff conditions and exponentially small approximation errors. We discuss concrete forms of arterial bifurcation and available generalizations of the results, in particular, the Navier-Stokes system of equations. Bibliography: 59 titles.
Farag, Amany; Blegen, Mary; Gedney-Lose, Amalia; Lose, Daniel; Perkhounkova, Yelena
2017-05-01
Medication errors are one of the most frequently occurring errors in health care settings. The complexity of the ED work environment places patients at risk for medication errors. Most hospitals rely on nurses' voluntary medication error reporting, but these errors are under-reported. The purpose of this study was to examine the relationship among work environment (nurse manager leadership style and safety climate), social capital (warmth and belonging relationships and organizational trust), and nurses' willingness to report medication errors. A cross-sectional descriptive design using a questionnaire with a convenience sample of emergency nurses was used. Data were analyzed using descriptive, correlation, Mann-Whitney U, and Kruskal-Wallis statistics. A total of 71 emergency nurses were included in the study. Emergency nurses' willingness to report errors decreased as the nurses' years of experience increased (r = -0.25, P = .03). Their willingness to report errors increased when they received more feedback about errors (r = 0.25, P = .03) and when their managers used a transactional leadership style (r = 0.28, P = .01). ED nurse managers can modify their leadership style to encourage error reporting. Timely feedback after an error report is particularly important. Engaging experienced nurses to understand error root causes could increase voluntary error reporting. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nanda, Kaushik D.; Krylov, Anna I.
The equation-of-motion coupled-cluster (EOM-CC) methods provide a robust description of electronically excited states and their properties. Here, we present a formalism for two-photon absorption (2PA) cross sections for the equation-of-motion for excitation energies CC with single and double substitutions (EOM-CC for electronically excited states with single and double substitutions) wave functions. Rather than the response theory formulation, we employ the expectation-value approach which is commonly used within EOM-CC, configuration interaction, and algebraic diagrammatic construction frameworks. In addition to canonical implementation, we also exploit resolution-of-the-identity (RI) and Cholesky decomposition (CD) for the electron-repulsion integrals to reduce memory requirements and to increasemore » parallel efficiency. The new methods are benchmarked against the CCSD and CC3 response theories for several small molecules. We found that the expectation-value 2PA cross sections are within 5% from the quadratic response CCSD values. The RI and CD approximations lead to small errors relative to the canonical implementation (less than 4%) while affording computational savings. RI/CD successfully address the well-known issue of large basis set requirements for 2PA cross sections calculations. The capabilities of the new code are illustrated by calculations of the 2PA cross sections for model chromophores of the photoactive yellow and green fluorescent proteins.« less
NASA Astrophysics Data System (ADS)
Green, Sheldon
1993-09-01
A computer program error led to erroneous results in the titled paper. Corrected generalized IOS cross sections are significantly changed, especially at lower collision energies. These changes tend to cancel in predicted Raman linewidths; there is a systematic increase of 10-15 %, changing quantitative, but not qualitative, comparisons with experimental data.
Knowledge of Food and Drug Interactions among Nurses: Assessment Strategy for Continuing Education
ERIC Educational Resources Information Center
Enwerem, Nkechi M.; Okunji, Priscilla O.
2017-01-01
The effect of medication errors on patient quality care and safety is a critical ongoing concern requiring solutions. Although medication safety has been a concern of all healthcare professions, registered nurses play an important role in medication safety as patients' advocates. A cross sectional study with structured questionnaire on common FDI…
Zhang, Zhaojun; Zhang, Dong H
2014-10-14
Seven-dimensional time-dependent wave packet calculations have been carried out for the title reaction to obtain reaction probabilities and cross sections for CHD3 in J0 = 1, 2 rotationally excited initial states with k0 = 0 - J0 (the projection of CHD3 rotational angular momentum on its C3 axis). Under the centrifugal sudden (CS) approximation, the initial states with the projection of the total angular momentum on the body fixed axis (K0) equal to k0 are found to be much more reactive, indicating strong dependence of reactivity on the orientation of the reagent CHD3 with respect to the relative velocity between the reagents H and CHD3. However, at the coupled-channel (CC) level this dependence becomes much weak although in general the K0 specified cross sections for the K0 = k0 initial states remain primary to the overall cross sections, implying the Coriolis coupling is important to the dynamics of the reaction. The calculated CS and CC integral cross sections obtained after K0 averaging for the J0 = 1, 2 initial states with all different k0 are essentially identical to the corresponding CS and CC results for the J0 = 0 initial state, meaning that the initial rotational excitation of CHD3 up to J0 = 2, regardless of its initial k0, does not have any effect on the total cross sections for the title reaction, and the errors introduced by the CS approximation on integral cross sections for the rotationally excited J0 = 1, 2 initial states are the same as those for the J0 = 0 initial state.
Electron-impact ionization of silicon tetrachloride (SiCl4).
Basner, R; Gutkin, M; Mahoney, J; Tarnovsky, V; Deutsch, H; Becker, K
2005-08-01
We measured absolute partial cross sections for the formation of various singly charged and doubly charged positive ions produced by electron impact on silicon tetrachloride (SiCl4) using two different experimental techniques, a time-of-flight mass spectrometer (TOF-MS) and a fast-neutral-beam apparatus. The energy range covered was from the threshold to 900 eV in the TOF-MS and to 200 eV in the fast-neutral-beam apparatus. The results obtained by the two different experimental techniques were found to agree very well (better than their combined margins of error). The SiCl3(+) fragment ion has the largest partial ionization cross section with a maximum value of slightly above 6x10(-20) m2 at about 100 eV. The cross sections for the formation of SiCl4(+), SiCl+, and Cl+ have maximum values around 4x10(-20) m2. Some of the cross-section curves exhibit an unusual energy dependence with a pronounced low-energy maximum at an energy around 30 eV followed by a broad second maximum at around 100 eV. This is similar to what has been observed by us earlier for another Cl-containing molecule, TiCl4 [R. Basner, M. Schmidt, V. Tamovsky, H. Deutsch, and K. Becker, Thin Solid Films 374 291 (2000)]. The maximum cross-section values for the formation of the doubly charged ions, with the exception of SiCl3(++), are 0.05x10(-20) m2 or less. The experimentally determined total single ionization cross section of SiCl4 is compared with the results of semiempirical calculations.
Auble, Gregor T.; Holmquist-Johnson, Christopher L.; Mogen, Jim T.; Kaeding, Lynn R.; Bowen, Zachary H.
2009-01-01
Operation of Sherburne Dam in northcentral Montana has typically reduced winter streamflow in Swiftcurrent Creek downstream of the dam and resulted in passage limitations for bull trout (Salvelinus confluentus). We defined an empirical relation between discharge in Swiftcurrent Creek between Sherburne Dam and the downstream confluence with Boulder Creek and fish passage geometry by considering how the cross-sectional area of water changed as a function of discharge at a set of cross sections likely to limit fish passage. With a minimum passage window of 15 x 45 cm, passage at the cross sections increased strongly with discharge over the range of 1.2 to 24 cfs. Most cross sections did not satisfy the minimum criteria at 1.2 cfs, 25 percent had no passage at 12.7 cfs, whereas at 24 cfs all but one of 26 cross sections had some passage and 90 percent had more than 3 m of width satisfying the minimum criteria. Sensitivity analysis suggests that the overall results are not highly dependent on exact dimensions of the minimum passage window. Combining these results with estimates of natural streamflow in the study reach further suggests that natural streamflow provided adequate passage at some times in most months and locations in the study reach, although not for all individual days and locations. Limitations of our analysis include assumptions about minimum passage geometry, measurement error, limitations of the cross-sectional model we used to characterize passage, the relation of Sherburne Dam releases to streamflow in the downstream study reach in the presence of ephemeral accretions, and the relation of passage geometry as we have measured it to fish responses of movement, stranding, and mortality, especially in the presence of ice cover.
Emergency department discharge prescription errors in an academic medical center
Belanger, April; Devine, Lauren T.; Lane, Aaron; Condren, Michelle E.
2017-01-01
This study described discharge prescription medication errors written for emergency department patients. This study used content analysis in a cross-sectional design to systematically categorize prescription errors found in a report of 1000 discharge prescriptions submitted in the electronic medical record in February 2015. Two pharmacy team members reviewed the discharge prescription list for errors. Open-ended data were coded by an additional rater for agreement on coding categories. Coding was based upon majority rule. Descriptive statistics were used to address the study objective. Categories evaluated were patient age, provider type, drug class, and type and time of error. The discharge prescription error rate out of 1000 prescriptions was 13.4%, with “incomplete or inadequate prescription” being the most commonly detected error (58.2%). The adult and pediatric error rates were 11.7% and 22.7%, respectively. The antibiotics reviewed had the highest number of errors. The highest within-class error rates were with antianginal medications, antiparasitic medications, antacids, appetite stimulants, and probiotics. Emergency medicine residents wrote the highest percentage of prescriptions (46.7%) and had an error rate of 9.2%. Residents of other specialties wrote 340 prescriptions and had an error rate of 20.9%. Errors occurred most often between 10:00 am and 6:00 pm. PMID:28405061
Three Dimensional Cross-Sectional Properties From Bone Densitometry
NASA Technical Reports Server (NTRS)
Cleek, Tammy M.; Whalen, Robert T.; Dalton, Bonnie P. (Technical Monitor)
2001-01-01
Bone densitometry has previously been used to obtain cross-sectional properties of bone in a single scan plane. Using three non-coplanar scans, we have extended the method to obtain the principal area Moments of inertia and orientations of the principal axes at each cross-section along the length of the scan. Various 5 aluminum phantoms were used to examine scanner characteristics to develop the highest accuracy possible for in vitro non-invasive analysis of mass distribution. Factors considered included X-ray photon energy, initial scan orientation, the included angle of the 3 scans, and Imin/Imax ratios. Principal moments of inertia were accurate to within 3.1% and principal angles were within 1 deg. of the expected value for phantoms scanned with included angles of 60 deg. and 90 deg. at the higher X-ray photon energy. Low standard deviations in error also 10 indicate high precision of calculated measurements with these included angles. Accuracy and precision decreased slightly when the included angle was reduced to 30 deg. The method was then successfully applied to a pair of excised cadaveric tibiae. The accuracy and insensitivity of the algorithms to cross-sectional shape and changing isotropy (Imin/Imax) values when various included angles are used make this technique viable for future in vivo studies.
Charm production by muons and its role in scale-noninvariance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gollin, G D
1981-01-01
Interactions of 209 GeV muons in the Multimuon Spectrometer at Fermilab have yielded more than 8 x 10/sup 4/ events with two muons in the final state. After reconstruction and cuts, the data contain 20,072 events with (81 +- 10)% attributed to the diffractive production of charmed states decaying to muons. The cross section for diffractive charm muoproduction is 6.9(+1.9,-1.4) nb where the error includes systematic uncertainties. Extrapolated to Q/sup 2/ = 0 with sigma(Q/sup 2/) = sigma(0)(1 + Q/sup 2//..lambda../sup 2/)/sup -2/, the effective cross section for 178 (100) GeV photons is 750(+180,-130) (560(+200,-120)) nb and the parameter ..lambda..more » is 3.3 +- 0.2 (2.9 +- 0.2) GeV/c. The ..nu.. dependence of the cross section is similar to that of the photon-gluon-fusion model. A first determination of the structure function for diffractive charm production indicates that charm accounts for approximately 1/3 of the scale-noninvariance observed in inclusive muon-nucleon scattering at low Bjorken x. Okubo-Zweig-Iizuka selection rules and unitarity allow the muon data to set a 90%-confidence lower limit on the psi N total cross section of 0.9 mb.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thachuk, M.; McCourt, F.R.W.
1991-09-15
A series of centrifugal sudden (CS) and infinite-order sudden (IOS) approximations together with their corrected versions, respectively, the corrected centrifugal sudden (CCS) and corrected infinite-order sudden (CIOS) approximations, originally introduced by McLenithan and Secrest (J. Chem. Phys. {bold 80}, 2480 (1987)), have been compared with the close-coupled (CC) method for the N{sub 2}--He interaction. This extends previous work using the H{sub 2}--He system (J. Chem. Phys. {bold 93}, 3931 (1990)) to an interaction which is more anisotropic and more classical in nature. A set of eleven energy dependent cross sections, including both relaxation and production types, has been calculated usingmore » the {ital LF}- and {ital LA}-labeling schemes for the CS approximation, as well as the {ital KI}-, {ital KF}-, {ital KA}-, and {ital KM}-labeling schemes for the IOS approximation. The latter scheme is defined as {ital KM}={ital K}=max({ital k}{sub {ital j}},{ital k}{sub {ital j}{sub {ital I}}}). Further, a number of temperature dependent cross sections formed from thermal averages of the above set have also been compared at 100 and 200 K. These comparisons have shown that the CS approximation produced accurate results for relaxation type cross sections regardless of the {ital L}-labeling scheme chosen, but inaccurate results for production type cross sections. Further, except for one particular cross section, the CCS approximation did not generally improve the accuracy of the CS results using either the {ital LF}- or {ital LA}-labeling schemes. The accuracy of the IOS results vary greatly between the cross sections with the most accurate values given by the {ital KM}-labeling scheme. The CIOS approximation generally increases the accuracy of the corresponding IOS results but does not completely eliminate the errors associated with them.« less
A comparison between destructive and non-destructive techniques in determining coating thickness
NASA Astrophysics Data System (ADS)
Haider, F. I.; Suryanto; Ani, M. H.; Mahmood, M. H.
2018-01-01
Measuring coating thickness is an important part in research works related to coating applications. In general, techniques for measuring coating thickness may be divided into destructive and non-destructive methods which are commonly used depending on the applications. The objective of this study is to compare two methods measuring the coating thickness of electroplating copper coating on the austenitic stainless-steel substrate. The electroplating was carried out in a solution containing 200 g/L CuSO4, 100 g/L H2SO4 at room temperature and current of 40mA/cm2 during 20, 40, 60, 80 and 100 mins as coating periods. And the coating thickness was measured by two methods, cross sectional analysis as a destructive technique and weight gain as a non-destructive technique. The results show that at 20 mins coating time interval, the thickness measured by cross sectional method was 16.67 μm and by weight gain method was 17.37 μm, with difference of 0.7 μm and percentage error of 4.11%. This error increased to 5.27% at 100mins time interval, where the values of the thickness measured by cross sectional and weight gain were 86.33 μm and 81.9 μm respectively, and the difference was 4.43 μm. Moreover, though the weight gain method is fast and gives the indication for the termination of a coating process, information regarding the uniformity, porosity and the presence of cracks cannot be obtained. On the other hand, determining the coating thickness using destructive method will damage the sample.
Vector scattering analysis of TPF coronagraph pupil masks
NASA Astrophysics Data System (ADS)
Ceperley, Daniel P.; Neureuther, Andrew R.; Lieber, Michael D.; Kasdin, N. Jeremy; Shih, Ta-Ming
2004-10-01
Rigorous finite-difference time-domain electromagnetic simulation is used to simulate the scattering from proto-typical pupil mask cross-section geometries and to quantify the differences from the normally assumed ideal on-off behavior. Shaped pupil plane masks are a promising technology for the TPF coronagraph mission. However the stringent requirements placed on the optics require that the detailed behavior of the edge-effects of these masks be examined carefully. End-to-end optical system simulation is essential and an important aspect is the polarization and cross-section dependent edge-effects which are the subject of this paper. Pupil plane masks are similar in many respects to photomasks used in the integrated circuit industry. Simulation capabilities such as the FDTD simulator, TEMPEST, developed for analyzing polarization and intensity imbalance effects in nonplanar phase-shifting photomasks, offer a leg-up in analyzing coronagraph masks. However, the accuracy in magnitude and phase required for modeling a chronograph system is extremely demanding and previously inconsequential errors may be of the same order of magnitude as the physical phenomena under study. In this paper, effects of thick masks, finite conductivity metals, and various cross-section geometries on the transmission of pupil-plane masks are illustrated. Undercutting the edge shape of Cr masks improves the effective opening width to within λ/5 of the actual opening but TE and TM polarizations require opposite compensations. The deviation from ideal is examined at the reference plane of the mask opening. Numerical errors in TEMPEST, such as numerical dispersion, perfectly matched layer reflections, and source haze are also discussed along with techniques for mitigating their impacts.
Development of Ultra-Fine Multigroup Cross Section Library of the AMPX/SCALE Code Packages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeon, Byoung Kyu; Sik Yang, Won; Kim, Kang Seog
The Consortium for Advanced Simulation of Light Water Reactors Virtual Environment for Reactor Applications (VERA) neutronic simulator MPACT is being developed by Oak Ridge National Laboratory and the University of Michigan for various reactor applications. The MPACT and simplified MPACT 51- and 252-group cross section libraries have been developed for the MPACT neutron transport calculations by using the AMPX and Standardized Computer Analyses for Licensing Evaluations (SCALE) code packages developed at Oak Ridge National Laboratory. It has been noted that the conventional AMPX/SCALE procedure has limited applications for fast-spectrum systems such as boiling water reactor (BWR) fuels with very highmore » void fractions and fast reactor fuels because of its poor accuracy in unresolved and fast energy regions. This lack of accuracy can introduce additional error sources to MPACT calculations, which is already limited by the Bondarenko approach for resolved resonance self-shielding calculation. To enhance the prediction accuracy of MPACT for fast-spectrum reactor analyses, the accuracy of the AMPX/SCALE code packages should be improved first. The purpose of this study is to identify the major problems of the AMPX/SCALE procedure in generating fast-spectrum cross sections and to devise ways to improve the accuracy. For this, various benchmark problems including a typical pressurized water reactor fuel, BWR fuels with various void fractions, and several fast reactor fuels were analyzed using the AMPX 252-group libraries. Isotopic reaction rates were determined by SCALE multigroup (MG) calculations and compared with continuous energy (CE) Monte Carlo calculation results. This reaction rate analysis revealed three main contributors to the observed differences in reactivity and reaction rates: (1) the limitation of the Bondarenko approach in coarse energy group structure, (2) the normalization issue of probability tables, and (3) neglect of the self-shielding effect of resonance-like cross sections at high energy range such as (n,p) cross section of Cl35. The first error source can be eliminated by an ultra-fine group (UFG) structure in which the broad scattering resonances of intermediate-weight nuclides can be represented accurately by a piecewise constant function. A UFG AMPX library was generated with modified probability tables and tested against various benchmark problems. The reactivity and reaction rates determined with the new UFG AMPX library agreed very well with respect to Monte Carlo Neutral Particle (MCNP) results. To enhance the lattice calculation accuracy without significantly increasing the computational time, performing the UFG lattice calculation in two steps was proposed. In the first step, a UFG slowing-down calculation is performed for the corresponding homogenized composition, and UFG cross sections are collapsed into an intermediate group structure. In the second step, the lattice calculation is performed for the intermediate group level using the condensed group cross sections. A preliminary test showed that the condensed library reproduces the results obtained with the UFG cross section library. This result suggests that the proposed two-step lattice calculation approach is a promising option to enhance the applicability of the AMPX/SCALE system to fast system analysis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Younes, W; Britt, H C; Wilhelmy, J B
The purpose of this note is to combine existing information on the {sup 237}U(n,f) cross section to determine if some consistency can be obtained for the neutron induced fission excitation of {sup 237}U. The neutron induced fission cross section of the 6.8 day {sup 237}U was measured directly by McNally et al. in 1968 using the Pommard nuclear device test. At the same time critical assembly measurements were done at Los Alamos using the Flattop assembly. A previous measurement was also made at LASL in 1954 with two different neutron sources, each peaked near 200 keV. The results were 0.66more » {+-} 0.10 b and 0.70 {+-} 0.07 b for the (n,f) cross section. More recently Younes and Britt have reanalyzed direct reaction charged particle data of Cramer and Britt that had determined the fission probability of the {sup 238}U compound nucleus as a function of nuclear excitation energy. They have combined fission probabilities with calculated neutron absorption cross sections, including corrections for the differences in angular momentum between the direct and neutron induced reactions. From this analysis they have extracted equivalent {sup 237}U(n,f) cross sections. The technique for extracting surrogate (n,f) cross sections from (t,pf) data has been demonstrated in a recent publication for the test case {sup 235}U(n,f). In addition to this experimental information, Lynn and Hayes have recently done a new theoretical study of the fission cross sections for a series of isotopes in this region. A summary plot of the data is shown in Fig. 1. Below 0.5 MeV the McNally, Cowan, and Younes-Britt results are in reasonable agreement. The average cross section in the Younes-Britt results, for En = 0.1 to 0.4 MeV, is 0.80 times the McNally values which is well within the errors of the McNally experiment. Above 0.5 MeV the McNally results diverge toward higher values. It should be noted that this divergence begins approximately at the {sup 237}Np threshold and that {sup 237}Np is the daughter of the 6.8 day {sup 237}U decay.« less
Ben Natan, Merav; Sharon, Ira; Mahajna, Marlen; Mahajna, Sara
2017-11-01
Medication errors are common among nursing students. Nonetheless, these errors are often underreported. To examine factors related to nursing students' intention to report medication errors, using the Theory of Planned Behavior, and to examine whether the theory is useful in predicting students' intention to report errors. This study has a descriptive cross-sectional design. Study population was recruited in a university and a large nursing school in central and northern Israel. A convenience sample of 250 nursing students took part in the study. The students completed a self-report questionnaire, based on the Theory of Planned Behavior. The findings indicate that students' intention to report medication errors was high. The Theory of Planned Behavior constructs explained 38% of variance in students' intention to report medication errors. The constructs of behavioral beliefs, subjective norms, and perceived behavioral control were found as affecting this intention, while the most significant factor was behavioral beliefs. The findings also reveal that students' fear of the reaction to disclosure of the error from superiors and colleagues may impede them from reporting the error. Understanding factors related to reporting medication errors is crucial to designing interventions that foster error reporting. Copyright © 2017 Elsevier Ltd. All rights reserved.
On the interaction of deaffrication and consonant harmony*
Dinnsen, Daniel A.; Gierut, Judith A.; Morrisette, Michele L.; Green, Christopher R.; Farris-Trimble, Ashley W.
2010-01-01
Error patterns in children’s phonological development are often described as simplifying processes that can interact with one another with different consequences. Some interactions limit the applicability of an error pattern, and others extend it to more words. Theories predict that error patterns interact to their full potential. While specific interactions have been documented for certain pairs of processes, no developmental study has shown that the range of typologically predicted interactions occurs for those processes. To determine whether this anomaly is an accidental gap or a systematic peculiarity of particular error patterns, two commonly occurring processes were considered, namely Deaffrication and Consonant Harmony. Results are reported from a cross-sectional and longitudinal study of 12 children (age 3;0 – 5;0) with functional phonological delays. Three interaction types were attested to varying degrees. The longitudinal results further instantiated the typology and revealed a characteristic trajectory of change. Implications of these findings are explored. PMID:20513256
Giraldo, Priscila; Corbella, Josep; Rodrigo, Carmen; Comas, Mercè; Sala, Maria; Castells, Xavier
2016-01-01
To identify opportunities for disclosing information on medical errors in Spain and issuing an apology, as well as legal-ethical barriers. A cross-sectional study was conducted through a questionnaire sent to health law and bioethics experts (n=46). A total of 39 experts (84.7%) responded that health providers should always disclose adverse events and 38 experts (82.6%) were in favour of issuing an apology. Thirty experts (65.2%) reported that disclosure of errors would not lead to professional liability. The main opportunity for increasing disclosure was by enhancing trust in the physician-patient relationship and the main barrier was fear of the outcomes of disclosing medical errors. There is a broad agreement on the lack of liability following disclosure/apology on adverse events and the need to develop a strategy for disclosure among support for physicians. Copyright © 2015 SESPAS. Published by Elsevier Espana. All rights reserved.
Resin distribution in second-growth ponderosa pine
B.H. Paul
1955-01-01
In a study of specific gravity of second-growth ponderosa pine, there was visible evidence of resin in a part of the specific gravity specimens. Each specimen contained 10 annual growth rings in cross sections taken at 4 heights in the merchantable length of the trees. Since the presence of resin introduced an uncertain amount of error in the specific gravity values,...
A robust algorithm for automated target recognition using precomputed radar cross sections
NASA Astrophysics Data System (ADS)
Ehrman, Lisa M.; Lanterman, Aaron D.
2004-09-01
Passive radar is an emerging technology that offers a number of unique benefits, including covert operation. Many such systems are already capable of detecting and tracking aircraft. The goal of this work is to develop a robust algorithm for adding automated target recognition (ATR) capabilities to existing passive radar systems. In previous papers, we proposed conducting ATR by comparing the precomputed RCS of known targets to that of detected targets. To make the precomputed RCS as accurate as possible, a coordinated flight model is used to estimate aircraft orientation. Once the aircraft's position and orientation are known, it is possible to determine the incident and observed angles on the aircraft, relative to the transmitter and receiver. This makes it possible to extract the appropriate radar cross section (RCS) from our simulated database. This RCS is then scaled to account for propagation losses and the receiver's antenna gain. A Rician likelihood model compares these expected signals from different targets to the received target profile. We have previously employed Monte Carlo runs to gauge the probability of error in the ATR algorithm; however, generation of a statistically significant set of Monte Carlo runs is computationally intensive. As an alternative to Monte Carlo runs, we derive the relative entropy (also known as Kullback-Liebler distance) between two Rician distributions. Since the probability of Type II error in our hypothesis testing problem can be expressed as a function of the relative entropy via Stein's Lemma, this provides us with a computationally efficient method for determining an upper bound on our algorithm's performance. It also provides great insight into the types of classification errors we can expect from our algorithm. This paper compares the numerically approximated probability of Type II error with the results obtained from a set of Monte Carlo runs.
Meisner, Eric M; Hager, Gregory D; Ishman, Stacey L; Brown, David; Tunkel, David E; Ishii, Masaru
2013-11-01
To evaluate the accuracy of three-dimensional (3D) airway reconstructions obtained using quantitative endoscopy (QE). We developed this novel technique to reconstruct precise 3D representations of airway geometries from endoscopic video streams. This method, based on machine vision methodologies, uses a post-processing step of the standard videos obtained during routine laryngoscopy and bronchoscopy. We hypothesize that this method is precise and will generate assessment of airway size and shape similar to those obtained using computed tomography (CT). This study was approved by the institutional review board (IRB). We analyzed video sequences from pediatric patients receiving rigid bronchoscopy. We generated 3D scaled airway models of the subglottis, trachea, and carina using QE. These models were compared to 3D airway models generated from CT. We used the CT data as the gold standard measure of airway size, and used a mixed linear model to estimate the average error in cross-sectional area and effective diameter for QE. The average error in cross sectional area (area sliced perpendicular to the long axis of the airway) was 7.7 mm(2) (variance 33.447 mm(4)). The average error in effective diameter was 0.38775 mm (variance 2.45 mm(2)), approximately 9% error. Our pilot study suggests that QE can be used to generate precise 3D reconstructions of airways. This technique is atraumatic, does not require ionizing radiation, and integrates easily into standard airway assessment protocols. We conjecture that this technology will be useful for staging airway disease and assessing surgical outcomes. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Large-scale collision cross-section profiling on a travelling wave ion mobility mass spectrometer
Lietz, Christopher B.; Yu, Qing; Li, Lingjun
2014-01-01
Ion mobility (IM) is a gas-phase electrophoretic method that separates ions according to charge and ion-neutral collision cross-section (CCS). Herein, we attempt to apply a travelling wave (TW) IM polyalanine calibration method to shotgun proteomics and create a large peptide CCS database. Mass spectrometry methods that utilize IM, such as HDMSE, often use high transmission voltages for sensitive analysis. However, polyalanine calibration has only been demonstrated with low voltage transmission used to prevent gas-phase activation. If polyalanine ions change conformation under higher transmission voltages used for HDMSE, the calibration may no longer be valid. Thus, we aimed to characterize the accuracy of calibration and CCS measurement under high transmission voltages on a TW IM instrument using the polyalanine calibration method and found that the additional error was not significant. We also evaluated the potential error introduced by liquid chromatography (LC)-HDMSE analysis, and found it to be insignificant as well, validating the calibration method. Finally, we demonstrated the utility of building a large-population peptide CCS database by investigating the effects of terminal lysine position, via LysC or LysN digestion, on the formation of two structural sub-families formed by triply charged ions. PMID:24845359
Crosby, Richard; Salazar, Laura F.; DiClemente, Ralph J.; Yarber, William L.; Caliendo, Angela M.; Staples-Horne, Michelle
2009-01-01
Objectives To identify the prevalence of condom use errors among detained female teens and to test two inter-related hypotheses concerning condom failure. Methods A cross-sectional survey of 134 female teens recruited within eight detention facilities. Measures were collected using audio-computer assisted self-interviewing. Assessment for the presence of C. trachomatis and N. gonorrhoeae was also conducted. Results Five forms of condom use errors/problems were common: not discussing condom use with the partner (34.3%), not having a condom when one was desired (48.5%), starting sex before application (21.6%), removing condoms before sex concludes (26.9%), and breakage (32.8%). Significant, associations were found between condom errors/problems and drug/alcohol use. Errors/problems with condom use were significantly higher among teens diagnosed with an STD (P=.039 for an index measure; P=.022 for a single-item measure). Conclusions Findings suggest that detained female teens may have experienced multiple condom use error and problems thereby increasing their vulnerability to STD acquisition. PMID:18082855
Effect of phase errors in stepped-frequency radar systems
NASA Astrophysics Data System (ADS)
Vanbrundt, H. E.
1988-04-01
Stepped-frequency waveforms are being considered for inverse synthetic aperture radar (ISAR) imaging from ship and airborne platforms and for detailed radar cross section (RCS) measurements of ships and aircraft. These waveforms make it possible to achieve resolutions of 1.0 foot by using existing radar designs and processing technology. One problem not yet fully resolved in using stepped-frequency waveform for ISAR imaging is the deterioration in signal level caused by random frequency error. Random frequency error of the stepped-frequency source results in reduced peak responses and increased null responses. The resulting reduced signal-to-noise ratio is range dependent. Two of the major concerns addressed in this report are radar range limitations for ISAR and the error in calibration for RCS measurements caused by differences in range between a passive reflector used for an RCS reference and the target to be measured. In addressing these concerns, NOSC developed an analysis to assess the tolerable frequency error in terms of resulting power loss in signal power and signal-to-phase noise.
Complex Correlation Calculation of e-H Total Cross Sections
NASA Technical Reports Server (NTRS)
Bhatia, A. K.; Temkin, A.; Fisher, Richard R. (Technical Monitor)
2001-01-01
Calculation of e-H total and elastic partial wave cross sections is being carried out using the complex correlation variational T-matrix method. In this preliminary study, elastic partial wave phase shifts are calculated with the correlation functions which are confined to be real. In that case the method reduces to the conventional optical potential approach with projection operators. The number of terms in the Hylleraas-type wave function for the S phase shifts is 95 while for the S it is 56, except for k=0.8 where it is 84. Our results, which are rigorous lower bounds, are given. They are seen to be in general agreement with those of Schwartz, but they are of 0 greater accuracy and outside of his error limits for k=0.3 and 0.4 for S. The main aim of this approach' is the application to higher energy scattering. By virtue of the complex correlation functions, the T matrix is not unitary so that elastic and total scattering cross sections are independent of each other. Our results will be compared specifically with those of Bray and Stelbovics.
Complex Correlation Calculation of e(-) - H Total Cross Sections
NASA Technical Reports Server (NTRS)
Bhatia, A. K.; Temkin, A.; Fisher, Richard R. (Technical Monitor)
2001-01-01
Calculation of e(-) - H total and elastic partial wave cross sections is being carried out using the complex correlation variational T-matrix method. In this preliminary study, elastic partial wave phase shifts are calculated with the correlation functions which are confined to be real. In that case the method reduces to the conventional optical potential approach with 2 projection operators. The number of terms in the Hylleraas-type wave function for the S-1 phase shifts is 95 while for the S-3 it is 56, except for k = 0.8 where it is 84. Our results, which are rigorous lower bounds, are seen to be in general agreement with those of Schwartz, but they are of greater accuracy and outside of his error limits for k = 0.3 and 0.4 for S-1. The main aim of this approach is the application to higher energy scattering. By virtue of the complex correlation functions, the T-matrix is not unitary so that elastic and total scattering cross sections are independent of each other. Our results will be compared specifically with those of Bray and Stelbovics.
Towards a Resolution of the Proton Form Factor Problem: New Electron and Positron Scattering Data
NASA Astrophysics Data System (ADS)
Adikaram, D.; Rimal, D.; Weinstein, L. B.; Raue, B.; Khetarpal, P.; Bennett, R. P.; Arrington, J.; Brooks, W. K.; Adhikari, K. P.; Afanasev, A. V.; Amaryan, M. J.; Anderson, M. D.; Anefalos Pereira, S.; Avakian, H.; Ball, J.; Battaglieri, M.; Bedlinskiy, I.; Biselli, A. S.; Bono, J.; Boiarinov, S.; Briscoe, W. J.; Burkert, V. D.; Carman, D. S.; Careccia, S.; Celentano, A.; Chandavar, S.; Charles, G.; Colaneri, L.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Dodge, G. E.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Filippi, A.; Fleming, J. A.; Fradi, A.; Garillon, B.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guegan, B.; Guidal, M.; Guo, L.; Hafidi, K.; Hakobyan, H.; Hanretty, C.; Harrison, N.; Hattawy, M.; Hicks, K.; Holtrop, M.; Hughes, S. M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Jenkins, D.; Jiang, H.; Jo, H. S.; Joo, K.; Joosten, S.; Kalantarians, N.; Keller, D.; Khandaker, M.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Koirala, S.; Kubarovsky, V.; Kuhn, S. E.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Markov, N.; Mattione, P.; Mayer, M.; McKinnon, B.; Mestayer, M. D.; Meyer, C. A.; Mirazita, M.; Mokeev, V.; Montgomery, R. A.; Moody, C. I.; Moutarde, H.; Movsisyan, A.; Camacho, C. Munoz; Nadel-Turonski, P.; Niccolai, S.; Niculescu, G.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Pasyuk, E.; Peña, C.; Pisano, S.; Pogorelko, O.; Price, J. W.; Procureur, S.; Prok, Y.; Protopopescu, D.; Puckett, A. J. R.; Ripani, M.; Rizzo, A.; Rosner, G.; Rossi, P.; Roy, P.; Sabatié, F.; Salgado, C.; Schott, D.; Schumacher, R. A.; Seder, E.; Sharabian, Y. G.; Simonyan, A.; Skorodumina, I.; Smith, E. S.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Sparveris, N.; Stepanyan, S.; Stoler, P.; Strauch, S.; Sytnik, V.; Taiuti, M.; Tian, Ye; Trivedi, A.; Ungaro, M.; Voskanyan, H.; Voutier, E.; Walford, N. K.; Watts, D. P.; Wei, X.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zhao, Z. W.; Zonta, I.; CLAS Collaboration
2015-02-01
There is a significant discrepancy between the values of the proton electric form factor, GEp, extracted using unpolarized and polarized electron scattering. Calculations predict that small two-photon exchange (TPE) contributions can significantly affect the extraction of GEp from the unpolarized electron-proton cross sections. We determined the TPE contribution by measuring the ratio of positron-proton to electron-proton elastic scattering cross sections using a simultaneous, tertiary electron-positron beam incident on a liquid hydrogen target and detecting the scattered particles in the Jefferson Lab CLAS detector. This novel technique allowed us to cover a wide range in virtual photon polarization (ɛ ) and momentum transfer (Q2) simultaneously, as well as to cancel luminosity-related systematic errors. The cross section ratio increases with decreasing ɛ at Q2=1.45 GeV2 . This measurement is consistent with the size of the form factor discrepancy at Q2≈1.75 GeV2 and with hadronic calculations including nucleon and Δ intermediate states, which have been shown to resolve the discrepancy up to 2 - 3 GeV2 .
NASA Technical Reports Server (NTRS)
Beck, S. M.
1975-01-01
A two-parameter scintillation spectrometer system developed and used to obtain proton, deuteron, and triton double differential cross sections from materials under 558-MeV-proton irradiation is described. The system measures both the time of flight of secondary particles over a 488-cm flight path and the energy deposited in a scintillator, 12.7 cm in diameter and 30.48 cm long. The time resolution of the system is 0.39 nsec. The calculated energy resolution based on this time resolution varies with energy from 1.6 precent to 7.75 percent for 50- and 558-MeV protons. Various systematic and statistical errors are evaluated, and the double differential cross sections for secondary proton and deutron production at 20 deg from a 2.35 g/sq cm thick beryllium target are shown as an example of the results obtainable with this system. The uncertainly in the cross sections for secondary protons varies with particle energy from approximately + or - 9 percent at 50 MeV to approximately + or - 11 percent at 558 MeV.
Self-spectral calibration for spectral domain optical coherence tomography
NASA Astrophysics Data System (ADS)
Zhang, Xianling; Gao, Wanrong; Bian, Haiyi; Chen, Chaoliang; Liao, Jiuling
2013-06-01
A different real-time self-wavelength calibration method for spectral domain optical coherence tomography is presented in which interference spectra measured from two arbitrary points on the tissue surface are used for calibration. The method takes advantages of two favorable conditions of optical coherence tomography (OCT) signal. First, the signal back-scattered from the tissue surface is generally much stronger than that from positions in the tissue interior, so the spectral component of the surface interference could be extracted from the measured spectrum. Second, the tissue surface is not a plane and a phase difference exists between the light reflected from two different points on the surface. Compared with the zero-crossing automatic method, the introduced method has the advantage of removing the error due to dispersion mismatch or the common phase error. The method is tested experimentally to demonstrate the improved signal-to-noise ratio, higher axial resolution, and slower sensitivity degradation with depth when compared to the use of the zero-crossing method and applied to two-dimensional cross-sectional images of human finger skin.
Farzi, Sedigheh; Moladoost, Azam; Bahrami, Masoud; Farzi, Saba; Etminani, Reza
2017-01-01
One of the goals of nursing is providing safe care, prevention of injury, and health promotion of patients. Patient safety in intensive care units is threatened for various reasons. This study aimed to survey patient safety culture from the perspective of nurses in intensive care units. This cross-sectional study was conducted in 2016. Sampling was done using the convenience method. The sample consisted of 367 nurses working in intensive care units of teaching hospitals affiliated to Isfahan University of Medical Sciences. Data collection was performed using a two-part questionnaire that included demographic and hospital survey on Patient Safety Culture (HSOPSC) questionnaire. Data analysis was done using descriptive statistics (mean and standard deviation). Among the 12 dimensions of safety culture, the nurses assigned the highest score to "team work within units" (97.3%) and "Organizational learning-continuous improvement" (84%). They assigned the least score to "handoffs and transitions"(21.1%), "non-punitive response to errors" (24.7%), "Staffing" (35.6%), "Communication openness" (47.5%), and "Teamwork across units" (49.4%). The patient safety culture dimensions have low levels that require adequate attention and essential measures of health care centers including facilitating teamwork, providing adequate staff, and developing a checklist of handoffs and transitions. Furthermore, to increase reporting error and to promote a patient safety culture in intensive care units, some strategies should be adopted including a system-based approach to deal with the error.
Romero-Delmastro, Alejandro; Kadioglu, Onur; Currier, G Frans; Cook, Tanner
2014-08-01
Cone-beam computed tomography images have been previously used for evaluation of alveolar bone levels around teeth before, during, and after orthodontic treatment. Protocols described in the literature have been vague, have used unstable landmarks, or have required several software programs, file conversions, or hand tracings, among other factors that could compromise the precision of the measurements. The purposes of this article are to describe a totally digital tooth-based superimposition method for the quantitative assessment of alveolar bone levels and to evaluate its reliability. Ultra cone-beam computed tomography images (0.1-mm reconstruction) from 10 subjects were obtained from the data pool of the University of Oklahoma; 80 premolars were measured twice by the same examiner and a third time by a second examiner to determine alveolar bone heights and thicknesses before and more than 6 months after orthodontic treatment using OsiriX (version 3.5.1; Pixeo, Geneva, Switzerland). Intraexaminer and interexaminer reliabilities were evaluated, and Dahlberg's formula was used to calculate the error of the measurements. Cross-sectional and longitudinal evaluations of alveolar bone levels were possible using a digital tooth-based superimposition method. The mean differences for buccal alveolar crest heights and thicknesses were below 0.10 mm for the same examiner and below 0.17 mm for all examiners. The ranges of errors for any measurement were between 0.02 and 0.23 mm for intraexaminer errors, and between 0.06 and 0.29 mm for interexaminer errors. This protocol can be used for cross-sectional or longitudinal assessment of alveolar bone levels with low interexaminer and intraexaminer errors, and it eliminates the use of less reliable or less stable landmarks and the need for multiple software programs and image printouts. Standardization of the methods for bone assessment in orthodontics is necessary; this method could be the answer to this need. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Crainiceanu, Ciprian M.; Caffo, Brian S.; Di, Chong-Zhi; Punjabi, Naresh M.
2009-01-01
We introduce methods for signal and associated variability estimation based on hierarchical nonparametric smoothing with application to the Sleep Heart Health Study (SHHS). SHHS is the largest electroencephalographic (EEG) collection of sleep-related data, which contains, at each visit, two quasi-continuous EEG signals for each subject. The signal features extracted from EEG data are then used in second level analyses to investigate the relation between health, behavioral, or biometric outcomes and sleep. Using subject specific signals estimated with known variability in a second level regression becomes a nonstandard measurement error problem. We propose and implement methods that take into account cross-sectional and longitudinal measurement error. The research presented here forms the basis for EEG signal processing for the SHHS. PMID:20057925
Topping, David J.; Wright, Scott A.
2016-05-04
It is commonly recognized that suspended-sediment concentrations in rivers can change rapidly in time and independently of water discharge during important sediment‑transporting events (for example, during floods); thus, suspended-sediment measurements at closely spaced time intervals are necessary to characterize suspended‑sediment loads. Because the manual collection of sufficient numbers of suspended-sediment samples required to characterize this variability is often time and cost prohibitive, several “surrogate” techniques have been developed for in situ measurements of properties related to suspended-sediment characteristics (for example, turbidity, laser-diffraction, acoustics). Herein, we present a new physically based method for the simultaneous measurement of suspended-silt-and-clay concentration, suspended-sand concentration, and suspended‑sand median grain size in rivers, using multi‑frequency arrays of single-frequency side‑looking acoustic-Doppler profilers. The method is strongly grounded in the extensive scientific literature on the incoherent scattering of sound by random suspensions of small particles. In particular, the method takes advantage of theory that relates acoustic frequency, acoustic attenuation, acoustic backscatter, suspended-sediment concentration, and suspended-sediment grain-size distribution. We develop the theory and methods, and demonstrate the application of the method at six study sites on the Colorado River and Rio Grande, where large numbers of suspended-sediment samples have been collected concurrently with acoustic attenuation and backscatter measurements over many years. The method produces acoustical measurements of suspended-silt-and-clay and suspended-sand concentration (in units of mg/L), and acoustical measurements of suspended-sand median grain size (in units of mm) that are generally in good to excellent agreement with concurrent physical measurements of these quantities in the river cross sections at these sites. In addition, detailed, step-by-step procedures are presented for the general river application of the method.Quantification of errors in sediment-transport measurements made using this acoustical method is essential if the measurements are to be used effectively, for example, to evaluate uncertainty in long-term sediment loads and budgets. Several types of error analyses are presented to evaluate (1) the stability of acoustical calibrations over time, (2) the effect of neglecting backscatter from silt and clay, (3) the bias arising from changes in sand grain size, (4) the time-varying error in the method, and (5) the influence of nonrandom processes on error. Results indicate that (1) acoustical calibrations can be stable for long durations (multiple years), (2) neglecting backscatter from silt and clay can result in unacceptably high bias, (3) two frequencies are likely required to obtain sand-concentration measurements that are unbiased by changes in grain size, depending on site-specific conditions and acoustic frequency, (4) relative errors in silt-and-clay- and sand-concentration measurements decrease substantially as concentration increases, and (5) nonrandom errors may arise from slow changes in the spatial structure of suspended sediment that affect the relations between concentration in the acoustically ensonified part of the cross section and concentration in the entire river cross section. Taken together, the error analyses indicate that the two-frequency method produces unbiased measurements of suspended-silt-and-clay and sand concentration, with errors that are similar to, or larger than, those associated with conventional sampling methods.
Nurses' attitudes and perceived barriers to the reporting of medication administration errors.
Yung, Hai-Peng; Yu, Shu; Chu, Chi; Hou, I-Ching; Tang, Fu-In
2016-07-01
(1) To explore the attitudes and perceived barriers to reporting medication administration errors and (2) to understand the characteristics of - and nurses' feelings - about error reports. Under-reporting of medication administration errors is a global concern related to the safety of patient care. Understanding nurses' attitudes and perceived barriers to error reporting is the initial step to increasing the reporting rate. A cross-sectional, descriptive survey with a self-administered questionnaire was completed by the nurses of a medical centre hospital in Taiwan. A total of 306 nurses participated in the study. Nurses' attitudes towards medication administration error reporting were inclined towards positive. The major perceived barrier was fear of the consequences after reporting. The results demonstrated that 88.9% of medication administration errors were reported orally, whereas 19.0% were reported through the hospital internet system. Self-recrimination was the common feeling of nurses after the commission of an medication administration error. Even if hospital management encourages errors to be reported without recrimination, nurses' attitudes toward medication administration error reporting are not very positive and fear is the most prominent barrier contributing to underreporting. Nursing managers should establish anonymous reporting systems and counselling classes to create a secure atmosphere to reduce nurses' fear and provide incentives to encourage reporting. © 2016 John Wiley & Sons Ltd.
Modification of Classical SPM for Slightly Rough Surface Scattering with Low Grazing Angle Incidence
NASA Astrophysics Data System (ADS)
Guo, Li-Xin; Wei, Guo-Hui; Kim, Cheyoung; Wu, Zhen-Sen
2005-11-01
Based on the impedance/admittance rough boundaries, the reflection coefficients and the scattering cross section with low grazing angle incidence are obtained for both VV and HH polarizations. The error of the classical perturbation method at grazing angle is overcome for the vertical polarization at a rough Neumann boundary of infinite extent. The derivation of the formulae and the numerical results show that the backscattering cross section depends on the grazing angle to the fourth power for both Neumann and Dirichlet boundary conditions with low grazing angle incidence. Our results can reduce to that of the classical small perturbation method by neglecting the Neumann and Dirichlet boundary conditions. The project supported by National Natural Science Foundation of China under Grant No. 60101001 and the National Defense Foundation of China
Frequency of under-corrected refractive errors in elderly Chinese in Beijing.
Xu, Liang; Li, Jianjun; Cui, Tongtong; Tong, Zhongbiao; Fan, Guizhi; Yang, Hua; Sun, Baochen; Zheng, Yuanyuan; Jonas, Jost B
2006-07-01
The aim of the study was to evaluate the prevalence of under-corrected refractive error among elderly Chinese in the Beijing area. The population-based, cross-sectional, cohort study comprised 4,439 subjects out of 5,324 subjects asked to participate (response rate 83.4%) with an age of 40+ years. It was divided into a rural part [1,973 (44.4%) subjects] and an urban part [2,466 (55.6%) subjects]. Habitual and best-corrected visual acuity was measured. Under-corrected refractive error was defined as an improvement in visual acuity of the better eye of at least two lines with best possible refractive correction. The rate of under-corrected refractive error was 19.4% (95% confidence interval, 18.2, 20.6). In a multiple regression analysis, prevalence and size of under-corrected refractive error in the better eye was significantly associated with lower level of education (P<0.001), female gender (P<0.001), and age (P=0.001). Under-correction of refractive error is relatively common among elderly Chinese in the Beijing area when compared with data from other populations.
Statistical Properties of SEE Rate Calculation in the Limits of Large and Small Event Counts
NASA Technical Reports Server (NTRS)
Ladbury, Ray
2007-01-01
This viewgraph presentation reviews the Statistical properties of Single Event Effects (SEE) rate calculations. The goal of SEE rate calculation is to bound the SEE rate, though the question is by how much. The presentation covers: (1) Understanding errors on SEE cross sections, (2) Methodology: Maximum Likelihood and confidence Contours, (3) Tests with Simulated data and (4) Applications.
Parity Violation in Proton-Proton Scattering at Intermediate Energies
DOE R&D Accomplishments Database
Yuan, V.; Frauenfelder, H.; Harper, R. W.; Bowman, J. D.; Carlini, R.; MacArthur, D. W.; Mischke, R. E.; Nagle, D. E.; Talaga, R. L.; McDonald, A. B.
1986-05-01
Results of a measurement of parity nonconservation in the anti p-p total cross sections at 800-MeV are presented. The dependence of transmission on beam properties and correction for systematic errors are discussed. The measured longitudinal asymmetry is A{sub L} = (+2.4 +- 1.1(statistical) +- 0.1(systematic)) x 10{sup -7}. A proposed experiment at 230 MeV is discussed.
Acquisition of Real-Time Operation Analytics for an Automated Serial Sectioning System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madison, Jonathan D.; Underwood, O. D.; Poulter, Gregory A.
Mechanical serial sectioning is a highly repetitive technique employed in metallography for the rendering of 3D reconstructions of microstructure. While alternate techniques such as ultrasonic detection, micro-computed tomography, and focused ion beam milling have progressed much in recent years, few alternatives provide equivalent opportunities for comparatively high resolutions over significantly sized cross-sectional areas and volumes. To that end, the introduction of automated serial sectioning systems has greatly heightened repeatability and increased data collection rates while diminishing opportunity for mishandling and other user-introduced errors. Unfortunately, even among current, state-of-the-art automated serial sectioning systems, challenges in data collection have not been fullymore » eradicated. Therefore, this paper highlights two specific advances to assist in this area; a non-contact laser triangulation method for assessment of material removal rates and a newly developed graphical user interface providing real-time monitoring of experimental progress. Furthermore, both are shown to be helpful in the rapid identification of anomalies and interruptions, while also providing comparable and less error-prone measures of removal rate over the course of these long-term, challenging, and innately destructive characterization experiments.« less
Acquisition of Real-Time Operation Analytics for an Automated Serial Sectioning System
Madison, Jonathan D.; Underwood, O. D.; Poulter, Gregory A.; ...
2017-03-22
Mechanical serial sectioning is a highly repetitive technique employed in metallography for the rendering of 3D reconstructions of microstructure. While alternate techniques such as ultrasonic detection, micro-computed tomography, and focused ion beam milling have progressed much in recent years, few alternatives provide equivalent opportunities for comparatively high resolutions over significantly sized cross-sectional areas and volumes. To that end, the introduction of automated serial sectioning systems has greatly heightened repeatability and increased data collection rates while diminishing opportunity for mishandling and other user-introduced errors. Unfortunately, even among current, state-of-the-art automated serial sectioning systems, challenges in data collection have not been fullymore » eradicated. Therefore, this paper highlights two specific advances to assist in this area; a non-contact laser triangulation method for assessment of material removal rates and a newly developed graphical user interface providing real-time monitoring of experimental progress. Furthermore, both are shown to be helpful in the rapid identification of anomalies and interruptions, while also providing comparable and less error-prone measures of removal rate over the course of these long-term, challenging, and innately destructive characterization experiments.« less
Barriers and facilitators to recovering from e-prescribing errors in community pharmacies.
Odukoya, Olufunmilola K; Stone, Jamie A; Chui, Michelle A
2015-01-01
To explore barriers and facilitators to recovery from e-prescribing errors in community pharmacies and to explore practical solutions for work system redesign to ensure successful recovery from errors. Cross-sectional qualitative design using direct observations, interviews, and focus groups. Five community pharmacies in Wisconsin. 13 pharmacists and 14 pharmacy technicians. Observational field notes and transcribed interviews and focus groups were subjected to thematic analysis guided by the Systems Engineering Initiative for Patient Safety (SEIPS) work system and patient safety model. Barriers and facilitators to recovering from e-prescription errors in community pharmacies. Organizational factors, such as communication, training, teamwork, and staffing levels, play an important role in recovering from e-prescription errors. Other factors that could positively or negatively affect recovery of e-prescription errors include level of experience, knowledge of the pharmacy personnel, availability or usability of tools and technology, interruptions and time pressure when performing tasks, and noise in the physical environment. The SEIPS model sheds light on key factors that may influence recovery from e-prescribing errors in pharmacies, including the environment, teamwork, communication, technology, tasks, and other organizational variables. To be successful in recovering from e-prescribing errors, pharmacies must provide the appropriate working conditions that support recovery from errors.
Parameter dependence of the MCNP electron transport in determining dose distributions.
Reynaert, N; Palmans, H; Thierens, H; Jeraj, R
2002-10-01
In this paper, a detailed study of the electron transport in MCNP is performed, separating the effects of the energy binning technique on the energy loss rate, the scattering angles, and the sub-step length as a function of energy. As this problem is already well known, in this paper we focus on the explanation as to why the default mode of MCNP can lead to large deviations. The resolution dependence was investigated as well. An error in the MCNP code in the energy binning technique in the default mode (DBCN 18 card = 0) was revealed, more specific in the updating of cross sections when a sub-step is performed corresponding to a high-energy loss. This updating error is not present in the ITS mode (DBCN 18 card = 1) and leads to a systematically lower dose deposition rate in the default mode. The effect is present for all energies studied (0.5-10 MeV) and depends on the geometrical resolution of the scoring regions and the energy grid resolution. The effect of the energy binning technique is of the same order of that of the updating error for energies below 2 MeV, and becomes less important for higher energies. For a 1 MeV point source surrounded by homogeneous water, the deviation of the default MCNP results at short distances attains 9% and remains approximately the same for all energies. This effect could be corrected by removing the completion of an energy step each time an electron changes from an energy bin during a sub-step. Another solution consists of performing all calculations in the ITS mode. Another problem is the resolution dependence, even in the ITS mode. The higher the resolution is chosen (the smaller the scoring regions) the faster the energy is deposited along the electron track. It is proven that this is caused by starting a new energy step when crossing a surface. The resolution effect should be investigated for every specific case when calculating dose distributions around beta sources. The resolution should not be higher than 0.85*(1-EFAC)*CSDA, where EFAC is the energy loss per energy step and CSDA a continuous slowing down approximation range. This effect could as well be removed by determining the cross sections for energy loss and multiple scattering at the average energy of an energy step and by sampling the cross sections for each sub-step. Overall, we conclude that MCNP cannot be used without a caution due to possible errors in the electron transport. When care is taken, it is possible to obtain correct results that are in agreement with other Monte Carlo codes.
UV absorption spectrum of the ClO dimer (Cl2O2) between 200 and 420 nm.
Papanastasiou, Dimitrios K; Papadimitriou, Vassileios C; Fahey, David W; Burkholder, James B
2009-12-10
The UV photolysis of Cl(2)O(2) (dichlorine peroxide) is a key step in the catalytic destruction of polar stratospheric ozone. In this study, the gas-phase UV absorption spectrum of Cl(2)O(2) was measured using diode array spectroscopy and absolute cross sections, sigma, are reported for the wavelength range 200-420 nm. Pulsed laser photolysis of Cl(2)O at 248 nm or Cl(2)/Cl(2)O mixtures at 351 nm at low temperature (200-228 K) and high pressure (approximately 700 Torr, He) was used to produce ClO radicals and subsequently Cl(2)O(2) via the termolecular ClO self-reaction. The Cl(2)O(2) spectrum was obtained from spectra recorded following the completion of the gas-phase ClO radical chemistry. The spectral analysis used observed isosbestic points at 271, 312.9, and 408.5 nm combined with reaction stoichiometry and chlorine mass balance to determine the Cl(2)O(2) spectrum. The Cl(2)O(2) UV absorption spectrum peaks at 244.5 nm with a cross section of 7.6(-0.5)(+0.8) x 10(-18) cm(2) molecule(-1) where the quoted error limits are 2sigma and include estimated systematic errors. The Cl(2)O(2) absorption cross sections obtained for wavelengths in the range 300-420 nm are in good agreement with the Cl(2)O(2) spectrum reported previously by Burkholder et al. (J. Phys. Chem. A 1990, 94, 687) and significantly higher than the values reported by Pope et al. (J. Phys. Chem. A 2007, 111, 4322). A possible explanation for the discrepancy in the Cl(2)O(2) cross section values with the Pope et al. study is discussed. Representative, atmospheric photolysis rate coefficients are calculated and a range of uncertainty estimated based on the determination of sigma(Cl(2)O(2))(lambda) in this work. Although improvements in our fundamental understanding of the photochemistry of Cl(2)O(2) are still desired, this work indicates that major revisions in current atmospheric chemical mechanisms are not required to simulate observed polar ozone depletion.
UV Absorption Spectrum of the ClO Dimer (Cl2O2) between 200 and 420 nm
NASA Astrophysics Data System (ADS)
Papanastasiou, Dimitrios K.; Papadimitriou, Vassileios C.; Fahey, David W.; Burkholder, James B.
2009-11-01
The UV photolysis of Cl2O2 (dichlorine peroxide) is a key step in the catalytic destruction of polar stratospheric ozone. In this study, the gas-phase UV absorption spectrum of Cl2O2 was measured using diode array spectroscopy and absolute cross sections, σ, are reported for the wavelength range 200-420 nm. Pulsed laser photolysis of Cl2O at 248 nm or Cl2/Cl2O mixtures at 351 nm at low temperature (200-228 K) and high pressure (˜700 Torr, He) was used to produce ClO radicals and subsequently Cl2O2 via the termolecular ClO self-reaction. The Cl2O2 spectrum was obtained from spectra recorded following the completion of the gas-phase ClO radical chemistry. The spectral analysis used observed isosbestic points at 271, 312.9, and 408.5 nm combined with reaction stoichiometry and chlorine mass balance to determine the Cl2O2 spectrum. The Cl2O2 UV absorption spectrum peaks at 244.5 nm with a cross section of 7.6-0.5+0.8 × 10-18 cm2 molecule-1 where the quoted error limits are 2σ and include estimated systematic errors. The Cl2O2 absorption cross sections obtained for wavelengths in the range 300-420 nm are in good agreement with the Cl2O2 spectrum reported previously by Burkholder et al. (J. Phys. Chem. A 1990, 94, 687) and significantly higher than the values reported by Pope et al. (J. Phys. Chem. A 2007, 111, 4322). A possible explanation for the discrepancy in the Cl2O2 cross section values with the Pope et al. study is discussed. Representative, atmospheric photolysis rate coefficients are calculated and a range of uncertainty estimated based on the determination of σCl2O2(λ) in this work. Although improvements in our fundamental understanding of the photochemistry of Cl2O2 are still desired, this work indicates that major revisions in current atmospheric chemical mechanisms are not required to simulate observed polar ozone depletion.
A clinic-based study of refractive errors, strabismus, and amblyopia in pediatric age-group.
Al-Tamimi, Elham R; Shakeel, Ayisha; Yassin, Sanaa A; Ali, Syed I; Khan, Umar A
2015-01-01
The purpose of this cross-sectional observational study was to determine the distribution and patterns of refractive errors, strabismus, and amblyopia in children seen at a pediatric eye care. The study was conducted in a Private Hospital in Dammam, Kingdom of Saudi Arabia, from March to July 2013. During this period, a total of 1350 children, aged 1-15 years were seen at this Center's Pediatric Ophthalmology Unit. All the children underwent complete ophthalmic examination with cycloplegic refraction. Refractive errors accounted for 44.4% of the cases, the predominant refractive error being hypermetropia which represented 83%. Strabismus and amblyopia were present in 38% and 9.1% of children, respectively. In this clinic-based study, the focus was on the frequency of refractive errors, strabismus, and amblyopia which were considerably high. Hypermetropia was the predominant refractive error in contrast to other studies in which myopia was more common. This could be attributed to the criteria for sample selection since it was clinic-based rather than a population-based study. However, it is important to promote public education on the significance of early detection of refractive errors, and have periodic screening in schools.
Sun, You-Wen; Liu, Wen-Qing; Wang, Shi-Mei; Huang, Shu-Hua; Yu, Xiao-Man
2011-10-01
A method of interference correction for nondispersive infrared multi-component gas analysis was described. According to the successive integral gas absorption models and methods, the influence of temperature and air pressure on the integral line strengths and linetype was considered, and based on Lorentz detuning linetypes, the absorption cross sections and response coefficients of H2O, CO2, CO, and NO on each filter channel were obtained. The four dimension linear regression equations for interference correction were established by response coefficients, the absorption cross interference was corrected by solving the multi-dimensional linear regression equations, and after interference correction, the pure absorbance signal on each filter channel was only controlled by the corresponding target gas concentration. When the sample cell was filled with gas mixture with a certain concentration proportion of CO, NO and CO2, the pure absorbance after interference correction was used for concentration inversion, the inversion concentration error for CO2 is 2.0%, the inversion concentration error for CO is 1.6%, and the inversion concentration error for NO is 1.7%. Both the theory and experiment prove that the interference correction method proposed for NDIR multi-component gas analysis is feasible.
PREVALENCE OF REFRACTIVE ERRORS IN MADRASSA STUDENTS OF HARIPUR DISTRICT.
Atta, Zoia; Arif, Abdus Salam; Ahmed, Iftikhar; Farooq, Umer
2015-01-01
Visual impairment due to refractive errors is one of the most common problems among school-age children and is the second leading cause of treatable blindness. The Right to Sight, a global initiative launched by a coalition of non-government organizations and the World Health Organization (WHO), aims to eliminate avoidable visual impairment and blindness at a global level. In order to achieve this goal it is important to know the prevalence of different refractive errors in a community. Children and teenagers are the most susceptible groups to be affected by refractive errors. So, this population needs to be screened for different types of refractive errors. The study was done with the objective to find the frequency of different types of refractive errors in students of madrassas between the ages of 5-20 years in Haripur. This cross sectional study was done with 300 students between ages of 5-20 years in Madrassas of Haripur. The students were screened for refractive errors and the types of the errors were noted. After screening for refractive errors-the glasses were prescribed to the students. Myopia being 52.6% was the most frequent refractive error in students, followed by hyperopia 28.4% and astigmatism 19%. This study showed that myopia is an important problem in madrassa population. Females and males are almost equally affected. Spectacle correction of refractive errors is the cheapest and easy solution of this problem.
Misagh, Pegah; Vazin, Afsaneh; Namazi, Soha
2018-01-01
This study was aimed at finding the occurrence rate of prescription errors in the outpatients› prescriptions written by faculty and non-faculty physicians practicing in Shiraz, Iran. In this cross-sectional study 2000 outpatient prescriptions were randomly collected from pharmacies affiliated with Shiraz University of Medical Sciences (SUMS) and social security insurance in Shiraz, Iran. Patient information including age, weight, diagnosis and chief complain were recorded. Physicians ‘characteristics were extracted from prescriptions. Prescription errors including errors in spelling, instruction, strength, dosage form and quantity as well as drug-drug interactions and contraindications were identified. The mean ± SD age of patients was 37.91 ± 21.10 years. Most of the patients were male (77.15%) and 81.50% of patients were adults. The average total number of drugs per prescription was 3.19 ± 1.60. The mean ± SD of prescription errors was 7.38 ± 4.06. Spelling error (26.4%), instruction error (21.03%), and strength error (19.18%) were the most frequent prescription errors. The mean ± SD of prescription errors was 7.83 ± 4.2 and 6.93 ± 3.88 in non-faculty and faculty physicians, respectively (P < 0.05). Number of prescription errors increased significantly as the number of prescribed drugs increased. All prescriptions had at least one error. The rate of prescription errors was higher in non-faculty physicians. Number of prescription errors related with the prescribed drugs in the prescription.
Effects of learning climate and registered nurse staffing on medication errors.
Chang, Yunkyung; Mark, Barbara
2011-01-01
Despite increasing recognition of the significance of learning from errors, little is known about how learning climate contributes to error reduction. The purpose of this study was to investigate whether learning climate moderates the relationship between error-producing conditions and medication errors. A cross-sectional descriptive study was done using data from 279 nursing units in 146 randomly selected hospitals in the United States. Error-producing conditions included work environment factors (work dynamics and nurse mix), team factors (communication with physicians and nurses' expertise), personal factors (nurses' education and experience), patient factors (age, health status, and previous hospitalization), and medication-related support services. Poisson models with random effects were used with the nursing unit as the unit of analysis. A significant negative relationship was found between learning climate and medication errors. It also moderated the relationship between nurse mix and medication errors: When learning climate was negative, having more registered nurses was associated with fewer medication errors. However, no relationship was found between nurse mix and medication errors at either positive or average levels of learning climate. Learning climate did not moderate the relationship between work dynamics and medication errors. The way nurse mix affects medication errors depends on the level of learning climate. Nursing units with fewer registered nurses and frequent medication errors should examine their learning climate. Future research should be focused on the role of learning climate as related to the relationships between nurse mix and medication errors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Zhaojun; Zhang, Dong H., E-mail: zhangdh@dicp.ac.cn
Seven-dimensional time-dependent wave packet calculations have been carried out for the title reaction to obtain reaction probabilities and cross sections for CHD{sub 3} in J{sub 0} = 1, 2 rotationally excited initial states with k{sub 0} = 0 − J{sub 0} (the projection of CHD{sub 3} rotational angular momentum on its C{sub 3} axis). Under the centrifugal sudden (CS) approximation, the initial states with the projection of the total angular momentum on the body fixed axis (K{sub 0}) equal to k{sub 0} are found to be much more reactive, indicating strong dependence of reactivity on the orientation of the reagentmore » CHD{sub 3} with respect to the relative velocity between the reagents H and CHD{sub 3}. However, at the coupled-channel (CC) level this dependence becomes much weak although in general the K{sub 0} specified cross sections for the K{sub 0} = k{sub 0} initial states remain primary to the overall cross sections, implying the Coriolis coupling is important to the dynamics of the reaction. The calculated CS and CC integral cross sections obtained after K{sub 0} averaging for the J{sub 0} = 1, 2 initial states with all different k{sub 0} are essentially identical to the corresponding CS and CC results for the J{sub 0} = 0 initial state, meaning that the initial rotational excitation of CHD{sub 3} up to J{sub 0} = 2, regardless of its initial k{sub 0}, does not have any effect on the total cross sections for the title reaction, and the errors introduced by the CS approximation on integral cross sections for the rotationally excited J{sub 0} = 1, 2 initial states are the same as those for the J{sub 0} = 0 initial state.« less
NASA Technical Reports Server (NTRS)
Huo, Winifred M.; Green, Sheldon; Langhoff, Stephen R. (Technical Monitor)
1995-01-01
Rotationally inelastic transitions of N2 have been studied in the coupled state (CS) and infinite-order-sudden (IOS) approximations, using the N2-N2 rigidrotor potential of van der Avoird et al. For benchmarking purposes, close coupling (CC) calculations have also been carried out over a limited energy range. The CC and CS cross sections have been obtained both with and without identical molecule exchange symmetry, whereas exchange was neglected in the IOS calculations. The CS results track the CC cross sections rather well; between 113 - 219 cm(exp -1) the average deviation is 14%. Comparison between the CS and IOS cross sections at the high energy end of the CS calculation, 500 - 680 cm(exp -1), shows that IOS is sensitive to the amount of inelasticity and the results for large DELTA J transitions are subject to larger errors. It is found that the state-to-state cross sections with even and odd exchange symmetry agree to better than 2% and are well represented as a sum of direct and exchange cross sections for distinguishable molecules, an indication of the applicability of a classical treatment for this system. This result, however, does not apply to partial cross sections for given total J, but arises from a near cancellation in summing over partial waves. In order to use rigid-rotor results for the calculation of effective rotational excitation rates of N2 in the v=1 vibrational level colliding with bath N2 molecules in the v=0 level, it is assumed that exchange scattering between molecules in different vibrational levels is negligible and direct scattering is independent of Y. Good agreement with room temperature experimental data is obtained. The effective rates determined using the IOS and energy corrected sudden (ECS) approximations are also in reasonable agreement with experiment, with the ECS results being somewhat better. The problem with a degeneracy factor in earlier cross section expressions for collisions between identical molecules is pointed out and corrected.
NASA Astrophysics Data System (ADS)
Waeldele, F.
1983-01-01
The influence of sample shape deviations on the measurement uncertainties and the optimization of computer aided coordinate measurement were investigated for a circle and a cylinder. Using the complete error propagation law in matrix form the parameter uncertainties are calculated, taking the correlation between the measurement points into account. Theoretical investigations show that the measuring points have to be equidistantly distributed and that for a cylindrical body a measuring point distribution along a cross section is better than along a helical line. The theoretically obtained expressions to calculate the uncertainties prove to be a good estimation basis. The simple error theory is not satisfactory for estimation. The complete statistical data analysis theory helps to avoid aggravating measurement errors and to adjust the number of measuring points to the required measuring uncertainty.
Vogel, M; Stern, H; Bauer, R; Bühlmeyer, K
1992-04-01
Although left ventricular (LV) mass may be important to judge effects of left-sided cardiac obstruction or hypertension, reproducible noninvasively determined normal data in the pediatric age group are scarce. To validate cross-sectional echocardiographic LV mass determination, our data were compared with LV mass assessed by magnetic resonance imaging (MRI). MRI was considered to be a good reference method because there is usually no problem in defining endo- and epicardial borders with MRI. LV mass was assessed in 14 children aged 5.3 years (10 days to 14.7 years) with a mean body surface area of 0.78 m2 (range 0.25 to 1.61). With cross-sectional echocardiography the epicardial and endocardial volumes were calculated using a Simpsons rule algorithm in the apical 2- and 4-chamber view. The difference between epi- and endocardial volumes was multiplied by 1.05 to yield the mass. Mass was assessed with MRI using a multislice technique; the area of each myocardial slice was calculated and multiplied with the slice thickness, and the resultant slice volumes were added to obtain the myocardial volume. On cross-sectional echocardiography, the mass was 55 g (range 12 to 126) or 64 g/m2 (range 46 to 79); on MRI it was 60 g (range 33 to 87) or 69 g/m2 (range 46 to 89). Regression analysis yielded an r value of 0.98 with a standard error of the estimate of 5.7 g or a 10% difference. In older children, LV mass determined by MRI was bigger than the one derived by echocardiography. It is concluded that cross-sectional echocardiography can reliably assess LV myocardial mass in pediatric patients.
Combustor air flow control method for fuel cell apparatus
Clingerman, Bruce J.; Mowery, Kenneth D.; Ripley, Eugene V.
2001-01-01
A method for controlling the heat output of a combustor in a fuel cell apparatus to a fuel processor where the combustor has dual air inlet streams including atmospheric air and fuel cell cathode effluent containing oxygen depleted air. In all operating modes, an enthalpy balance is provided by regulating the quantity of the air flow stream to the combustor to support fuel cell processor heat requirements. A control provides a quick fast forward change in an air valve orifice cross section in response to a calculated predetermined air flow, the molar constituents of the air stream to the combustor, the pressure drop across the air valve, and a look up table of the orifice cross sectional area and valve steps. A feedback loop fine tunes any error between the measured air flow to the combustor and the predetermined air flow.
HZETRN: A heavy ion/nucleon transport code for space radiations
NASA Technical Reports Server (NTRS)
Wilson, John W.; Chun, Sang Y.; Badavi, Forooz F.; Townsend, Lawrence W.; Lamkin, Stanley L.
1991-01-01
The galactic heavy ion transport code (GCRTRN) and the nucleon transport code (BRYNTRN) are integrated into a code package (HZETRN). The code package is computer efficient and capable of operating in an engineering design environment for manned deep space mission studies. The nuclear data set used by the code is discussed including current limitations. Although the heavy ion nuclear cross sections are assumed constant, the nucleon-nuclear cross sections of BRYNTRN with full energy dependence are used. The relation of the final code to the Boltzmann equation is discussed in the context of simplifying assumptions. Error generation and propagation is discussed, and comparison is made with simplified analytic solutions to test numerical accuracy of the final results. A brief discussion of biological issues and their impact on fundamental developments in shielding technology is given.
The photodetachment cross-section and threshold energy of negative ions in carbon dioxide
NASA Technical Reports Server (NTRS)
Helmy, E. M.; Woo, S. B.
1974-01-01
Threshold energy and sunlight photodetachment measurements on negative carbon dioxide ions, using a 2.5 kw light pressure xenon lamp, show that: (1) Electron affinity of CO3(+) is larger than 2.7 e.V. and that an isomeric form of CO3(+) is likely an error; (2) The photodetachment cross section of CO3(-) will roughly be like a step function across the range of 4250 to 2500A, having its threshold energy at 4250A; (3) Sunlight photodetachment rate for CO3(-) is probably much smaller than elsewhere reported; and (4) The probability of having photodetached electrons re-attach to form negative ions is less than 1%. Mass identifying drift tube tests confirm that the slower ion is CO3(-), formed through the O(-) + 2CO2 yields CO3(-) + CO2 reaction.
NASA Astrophysics Data System (ADS)
Delogu, A.; Furini, F.
1991-09-01
Increasing interest in radar cross section (RCS) reduction is placing new demands on theoretical, computation, and graphic techniques for calculating scattering properties of complex targets. In particular, computer codes capable of predicting the RCS of an entire aircraft at high frequency and of achieving RCS control with modest structural changes, are becoming of paramount importance in stealth design. A computer code, evaluating the RCS of arbitrary shaped metallic objects that are computer aided design (CAD) generated, and its validation with measurements carried out using ALENIA RCS test facilities are presented. The code, based on the physical optics method, is characterized by an efficient integration algorithm with error control, in order to contain the computer time within acceptable limits, and by an accurate parametric representation of the target surface in terms of bicubic splines.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Jian; Casey, Cameron P.; Zheng, Xueyun
Motivation: Drift tube ion mobility spectrometry (DTIMS) is increasingly implemented in high throughput omics workflows, and new informatics approaches are necessary for processing the associated data. To automatically extract arrival times for molecules measured by DTIMS coupled with mass spectrometry and compute their associated collisional cross sections (CCS) we created the PNNL Ion Mobility Cross Section Extractor (PIXiE). The primary application presented for this algorithm is the extraction of information necessary to create a reference library containing accu-rate masses, DTIMS arrival times and CCSs for use in high throughput omics analyses. Results: We demonstrate the utility of this approach bymore » automatically extracting arrival times and calculating the associated CCSs for a set of endogenous metabolites and xenobiotics. The PIXiE-generated CCS values were identical to those calculated by hand and within error of those calcu-lated using commercially available instrument vendor software.« less
NASA Technical Reports Server (NTRS)
Lahti, G. P.; Mueller, R. A.
1973-01-01
Measurements of MeV neutron were made at the surface of a lithium hydride and depleted uranium shielded reactor. Four shield configurations were considered: these were assembled progressively with cylindrical shells of 5-centimeter-thick depleted uranium, 13-centimeter-thick lithium hydride, 5-centimeter-thick depleted uranium, 13-centimeter-thick lithium hydride, 5-centimeter-thick depleted uranium, and 3-centimeter-thick depleted uranium. Measurements were made with a NE-218 scintillation spectrometer; proton pulse height distributions were differentiated to obtain neutron spectra. Calculations were made using the two-dimensional discrete ordinates code DOT and ENDF/B (version 3) cross sections. Good agreement between measured and calculated spectral shape was observed. Absolute measured and calculated fluxes were within 50 percent of one another; observed discrepancies in absolute flux may be due to cross section errors.
Acheampong, Franklin; Tetteh, Ashalley Raymond; Anto, Berko Panyin
2016-12-01
This study determined the incidence, types, clinical significance, and potential causes of medication administration errors (MAEs) at the emergency department (ED) of a tertiary health care facility in Ghana. This study used a cross-sectional nonparticipant observational technique. Study participants (nurses) were observed preparing and administering medication at the ED of a 2000-bed tertiary care hospital in Accra, Ghana. The observations were then compared with patients' medication charts, and identified errors were clarified with staff for possible causes. Of the 1332 observations made, involving 338 patients and 49 nurses, 362 had errors, representing 27.2%. However, the error rate excluding "lack of drug availability" fell to 12.8%. Without wrong time error, the error rate was 22.8%. The 2 most frequent error types were omission (n = 281, 77.6%) and wrong time (n = 58, 16%) errors. Omission error was mainly due to unavailability of medicine, 48.9% (n = 177). Although only one of the errors was potentially fatal, 26.7% were definitely clinically severe. The common themes that dominated the probable causes of MAEs were unavailability, staff factors, patient factors, prescription, and communication problems. This study gives credence to similar studies in different settings that MAEs occur frequently in the ED of hospitals. Most of the errors identified were not potentially fatal; however, preventive strategies need to be used to make life-saving processes such as drug administration in such specialized units error-free.
Refractive errors in children and adolescents in Bucaramanga (Colombia).
Galvis, Virgilio; Tello, Alejandro; Otero, Johanna; Serrano, Andrés A; Gómez, Luz María; Castellanos, Yuly
2017-01-01
The aim of this study was to establish the frequency of refractive errors in children and adolescents aged between 8 and 17 years old, living in the metropolitan area of Bucaramanga (Colombia). This study was a secondary analysis of two descriptive cross-sectional studies that applied sociodemographic surveys and assessed visual acuity and refraction. Ametropias were classified as myopic errors, hyperopic errors, and mixed astigmatism. Eyes were considered emmetropic if none of these classifications were made. The data were collated using free software and analyzed with STATA/IC 11.2. One thousand two hundred twenty-eight individuals were included in this study. Girls showed a higher rate of ametropia than boys. Hyperopic refractive errors were present in 23.1% of the subjects, and myopic errors in 11.2%. Only 0.2% of the eyes had high myopia (≤-6.00 D). Mixed astigmatism and anisometropia were uncommon, and myopia frequency increased with age. There were statistically significant steeper keratometric readings in myopic compared to hyperopic eyes. The frequency of refractive errors that we found of 36.7% is moderate compared to the global data. The rates and parameters statistically differed by sex and age groups. Our findings are useful for establishing refractive error rate benchmarks in low-middle-income countries and as a baseline for following their variation by sociodemographic factors.
Kim, Myoung Soo
2012-08-01
The purpose of this cross-sectional study was to examine current status of IT-based medication error prevention system construction and the relationships among system construction, medication error management climate and perception for system use. The participants were 124 patient safety chief managers working for 124 hospitals with over 300 beds in Korea. The characteristics of the participants, construction status and perception of systems (electric pharmacopoeia, electric drug dosage calculation system, computer-based patient safety reporting and bar-code system) and medication error management climate were measured in this study. The data were collected between June and August 2011. Descriptive statistics, partial Pearson correlation and MANCOVA were used for data analysis. Electric pharmacopoeia were constructed in 67.7% of participating hospitals, computer-based patient safety reporting systems were constructed in 50.8%, electric drug dosage calculation systems were in use in 32.3%. Bar-code systems showed up the lowest construction rate at 16.1% of Korean hospitals. Higher rates of construction of IT-based medication error prevention systems resulted in greater safety and a more positive error management climate prevailed. The supportive strategies for improving perception for use of IT-based systems would add to system construction, and positive error management climate would be more easily promoted.
Shields, Richard K.; Dudley-Javoroski, Shauna; Boaldin, Kathryn M.; Corey, Trent A.; Fog, Daniel B.; Ruen, Jacquelyn M.
2012-01-01
Objectives To determine (1) the error attributable to external tibia-length measurements by using peripheral quantitative computed tomography (pQCT) and (2) the effect these errors have on scan location and tibia trabecular bone mineral density (BMD) after spinal cord injury (SCI). Design Blinded comparison and criterion standard in matched cohorts. Setting Primary care university hospital. Participants Eight able-bodied subjects underwent tibia length measurement. A separate cohort of 7 men with SCI and 7 able-bodied age-matched male controls underwent pQCT analysis. Interventions Not applicable. Main Outcome Measures The projected worst-case tibia-length–measurement error translated into a pQCT slice placement error of ±3mm. We collected pQCT slices at the distal 4% tibia site, 3mm proximal and 3mm distal to that site, and then quantified BMD error attributable to slice placement. Results Absolute BMD error was greater for able-bodied than for SCI subjects (5.87mg/cm3 vs 4.5mg/cm3). However, the percentage error in BMD was larger for SCI than able-bodied subjects (4.56% vs 2.23%). Conclusions During cross-sectional studies of various populations, BMD differences up to 5% may be attributable to variation in limb-length–measurement error. PMID:17023249
Ratio of He{sup 2+}/He{sup +} from 80 to 800 eV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samson, J.A.R.; Stolte, W.C.; He, Z.X.
1997-04-01
The importance of studying the double ionization of He by single photons lies in the fact that He presents the simplest structure for the study of electron correlation processes. Even so it has proved a challenging problem to understand and describe theoretically. Surprisingly, it has also proved difficult to agree experimentally on the absolute values of the He{sup 2+}/He{sup +} ratios. The availability of new synchrotron facilities with high intensity light outputs have increased the experimental activity in this area. However, by the very nature of those continuum sources systematic errors occur due to the presence of higher order spectramore » and great care must be exercised. The authors have measured the He{sup 2+}/He{sup +} ratios over a period of 5 years, the last three at the ALS utilizing beamlines 9.0.1 and 6.3.2. The sources of systematic errors that they have considered include: scattered light, higher order spectra, detector sensitivity to differently charged ions, discriminator levels in the counting equipment, gas purity, and stray electrons from filters and metal supports. The measurements have been made at three different synchrotron facilities with different types of monochromators and their potential for different sources of systematic errors. However, the authors data from all these different measurements agree within a few percent of each other. From the above results and their precision total photoionization cross sections for He, the authors can obtain the absolute photoionization cross section for He{sup 2+}. They find similar near perfect agreement with several of the latest calculations.« less
Neutrino Nucleon Elastic Scattering in MiniBooNE
NASA Astrophysics Data System (ADS)
Cox, D. Christopher
2007-12-01
Neutrino nucleon elastic scattering νN→νN is a fundamental process of the weak interaction, and can be used to study the structure of the nucleon. This is the third largest scattering process in MiniBooNE comprising ˜15% of all neutrino interactions. Analysis of this sample has yielded a neutral current elastic differential cross section as a function of Q2 that agrees within errors to model predictions.
ERIC Educational Resources Information Center
Xin Zhang; Shouxin Liu; Booxin Li; Na An; Fan Zhang
2004-01-01
A multipurpose apparatus that can be used to measure the viscosity of solution by the Ostwald method and the surface tension of solution by the drop-weight method or by the capillary-rise method is developed. The apparatus is convenient for in-situ preparation of solutions of different concentrations and avoids the error that frothing of the…
Percent area coverage through image analysis
NASA Astrophysics Data System (ADS)
Wong, Chung M.; Hong, Sung M.; Liu, De-Ling
2016-09-01
The notion of percent area coverage (PAC) has been used to characterize surface cleanliness levels in the spacecraft contamination control community. Due to the lack of detailed particle data, PAC has been conventionally calculated by multiplying the particle surface density in predetermined particle size bins by a set of coefficients per MIL-STD-1246C. In deriving the set of coefficients, the surface particle size distribution is assumed to follow a log-normal relation between particle density and particle size, while the cross-sectional area function is given as a combination of regular geometric shapes. For particles with irregular shapes, the cross-sectional area function cannot describe the true particle area and, therefore, may introduce error in the PAC calculation. Other errors may also be introduced by using the lognormal surface particle size distribution function that highly depends on the environmental cleanliness and cleaning process. In this paper, we present PAC measurements from silicon witness wafers that collected fallouts from a fabric material after vibration testing. PAC calculations were performed through analysis of microscope images and compare them to values derived through the MIL-STD-1246C method. Our results showed that the MIL-STD-1246C method does provide a reasonable upper bound to the PAC values determined through image analysis, in particular for PAC values below 0.1.
Improved effectiveness of performance monitoring in amateur instrumental musicians☆
Jentzsch, Ines; Mkrtchian, Anahit; Kansal, Nayantara
2014-01-01
Here we report a cross-sectional study investigating the influence of instrumental music practice on the ability to monitor for and respond to processing conflicts and performance errors. Behavioural and electrophysiological indicators of response monitoring in amateur musicians with various skill levels were collected using simple conflict tasks. The results show that instrumental musicians are better able than non-musicians to detect conflicts and errors as indicated by systematic increases in the amplitude of the error-related negativity and the N200 with increasing levels of instrumental practice. Also, high levels of musical training were associated with more efficient and less reactive responses after experience of conflicts and errors as indicated by reduced post-error interference and post-conflict processing adjustments. Together, the present findings suggest that playing a musical instrument might improve the ability to monitor our behavior and adjust our responses effectively when needed. As these processes are amongst the first to be affected by cognitive aging, our evidence could promote musical activity as a realistic intervention to slow or even prevent age-related decline in frontal cortex mediated executive functioning. PMID:24056298
2017-01-01
Background Dispensing errors are inevitable occurrences in community pharmacies across the world. Objective This study aimed to identify the community pharmacists' perception towards dispensing errors in the community pharmacies in Gondar town, Northwest Ethiopia. Methods A cross-sectional study was conducted among 47 community pharmacists selected through convenience sampling. Data were analyzed using SPSS version 20. Descriptive statistics, Mann–Whitney U test, and Pearson's Chi-square test of independence were conducted with P ≤ 0.05 considered statistically significant. Result The majority of respondents were in the 23–28-year age group (N = 26, 55.3%) and with at least B.Pharm degree (N = 25, 53.2%). Poor prescription handwriting and similar/confusing names were perceived to be the main contributing factors while all the strategies and types of dispensing errors were highly acknowledged by the respondents. Group differences (P < 0.05) in opinions were largely due to educational level and age. Conclusion Dispensing errors were associated with prescribing quality and design of dispensary as well as dispensing procedures. Opinion differences relate to age and educational status of the respondents. PMID:28612023
Asmelashe Gelayee, Dessalegn; Binega Mekonnen, Gashaw
2017-01-01
Dispensing errors are inevitable occurrences in community pharmacies across the world. This study aimed to identify the community pharmacists' perception towards dispensing errors in the community pharmacies in Gondar town, Northwest Ethiopia. A cross-sectional study was conducted among 47 community pharmacists selected through convenience sampling. Data were analyzed using SPSS version 20. Descriptive statistics, Mann-Whitney U test, and Pearson's Chi-square test of independence were conducted with P ≤ 0.05 considered statistically significant. The majority of respondents were in the 23-28-year age group ( N = 26, 55.3%) and with at least B.Pharm degree ( N = 25, 53.2%). Poor prescription handwriting and similar/confusing names were perceived to be the main contributing factors while all the strategies and types of dispensing errors were highly acknowledged by the respondents. Group differences ( P < 0.05) in opinions were largely due to educational level and age. Dispensing errors were associated with prescribing quality and design of dispensary as well as dispensing procedures. Opinion differences relate to age and educational status of the respondents.
[Nature or nurture: effects of parental ametropia on children's refractive errors].
Landmann, A; Bechrakis, E
2013-12-01
The aim of this study was to quantify the degree of association between juvenile refraction errors and parental refraction status. Using a simple questionnaire we conducted a cross-sectional study to determine the prevalence and magnitudes of refractive errors and of parental refraction status in a sample (n=728) of 10- to 18-year-old Austrian grammar school students. Students with myopia or hyperopia were more likely to have ametropic parents and refraction was more myopic in juveniles with one or two parents being ametropic. The prevalence of myopia in children with 2 ametropic parents was 54%, decreasing to 35% in pupils with 1 and to 13% in children with no ametropic parents. The odds ratio for 1 and 2 compared with no ametropic parents was 8.3 and 3.7 for myopia and 1.3 and 1.6 for hyperopia, respectively. Furthermore, the data indicate a stronger influence of the maternal ametropia on children's refractive errors than paternal ametropia. Genetic factors play a significant role in refractive error and may be of dominant influence for school myopia under conditions of low environmental variation.
Parental Cognitive Errors Mediate Parental Psychopathology and Ratings of Child Inattention.
Haack, Lauren M; Jiang, Yuan; Delucchi, Kevin; Kaiser, Nina; McBurnett, Keith; Hinshaw, Stephen; Pfiffner, Linda
2017-09-01
We investigate the Depression-Distortion Hypothesis in a sample of 199 school-aged children with ADHD-Predominantly Inattentive presentation (ADHD-I) by examining relations and cross-sectional mediational pathways between parental characteristics (i.e., levels of parental depressive and ADHD symptoms) and parental ratings of child problem behavior (inattention, sluggish cognitive tempo, and functional impairment) via parental cognitive errors. Results demonstrated a positive association between parental factors and parental ratings of inattention, as well as a mediational pathway between parental depressive and ADHD symptoms and parental ratings of inattention via parental cognitive errors. Specifically, higher levels of parental depressive and ADHD symptoms predicted higher levels of cognitive errors, which in turn predicted higher parental ratings of inattention. Findings provide evidence for core tenets of the Depression-Distortion Hypothesis, which state that parents with high rates of psychopathology hold negative schemas for their child's behavior and subsequently, report their child's behavior as more severe. © 2016 Family Process Institute.
Cheng, Dunlei; Branscum, Adam J; Stamey, James D
2010-07-01
To quantify the impact of ignoring misclassification of a response variable and measurement error in a covariate on statistical power, and to develop software for sample size and power analysis that accounts for these flaws in epidemiologic data. A Monte Carlo simulation-based procedure is developed to illustrate the differences in design requirements and inferences between analytic methods that properly account for misclassification and measurement error to those that do not in regression models for cross-sectional and cohort data. We found that failure to account for these flaws in epidemiologic data can lead to a substantial reduction in statistical power, over 25% in some cases. The proposed method substantially reduced bias by up to a ten-fold margin compared to naive estimates obtained by ignoring misclassification and mismeasurement. We recommend as routine practice that researchers account for errors in measurement of both response and covariate data when determining sample size, performing power calculations, or analyzing data from epidemiological studies. 2010 Elsevier Inc. All rights reserved.
Visual impairment in urban school children of low-income families in Kolkata, India.
Ghosh, Sambuddha; Mukhopadhyay, Udayaditya; Maji, Dipankar; Bhaduri, Gautam
2012-01-01
To evaluate pattern of visual impairment in school children from low-income families in Kolkata, India, an institutional cross-sectional study was conducted among 2570 children of 10 primary schools. Ocular examination including refraction was done and pattern of visual impairment and refractive error was studied. The age range was 6-14 years. Refractive error was seen in 14.7%. Only 4 children were already wearing correction. Myopia and hypermetropia was present in 307 (11.9%) and 65 (2.5%) children, respectively. Visual acuity of less than 6/12 in better eye was present in 109 (4.2%) and 5 (0.2%) children pre- and post-correction, respectively. Eighteen children had amblyopia. Although prevalence of refractive error in this group is less compared to school children of all income categories reported from other cities of India, it is more compared to school children of all income categories from the same city. Refractive error mostly remains uncorrected in this group.
The role of urgency in maladaptive behaviors.
Anestis, Michael D; Selby, Edward A; Joiner, Thomas E
2007-12-01
Prior work on maladaptive behaviors has cited impulsivity as a risk factor. The concept of impulsivity, however, fails to address the potential role of negative affect in such behaviors. The UPPS Impulsive Behavior Scale addresses this weakness by dividing impulsivity into four subscales: Urgency, Sensation Seeking, (lack of) Premeditation, and (lack of) Perseverance. We predicted that urgency, defined as the tendency, specifically in the face of negative affect, to act quickly and without planning, would predict elevations on three maladaptive behaviors--excessive reassurance seeking, drinking to cope, and bulimic symptoms as measured by the Eating Disorder Inventory--in both cross-sectional and longitudinal analyses in an undergraduate sample (N=70). Participants were assessed at two time points, 3-4 weeks apart. Urgency significantly predicted all three outcome variables cross-sectionally at both Time 1 and Time 2. Time 1 urgency significantly predicted Time 2 excessive reassurance seeking. Changes in urgency from Time 1 to Time 2 predicted changes in all three outcome variables. Results indicate a clear cross-sectional relationship between urgency and certain maladaptive behaviors. Additionally, some form of longitudinal relationship may exist between these variables, although the use of residual change scores precluded distinction between true change and change due to error.
Towards a Resolution of the Proton Form Factor Problem: New Electron and Positron Scattering Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adikaram, D.; Rimal, D.; Weinstein, L. B.
There is a significant discrepancy between the values of the proton electric form factor, GpE, extracted using unpolarized and polarized electron scattering. Calculations predict that small two-photon exchange (TPE) contributions can significantly affect the extraction of GpE from the unpolarized electron-proton cross sections. We determined the TPE contribution by measuring the ratio of positron-proton to electron-proton elastic scattering cross sections using a simultaneous, tertiary electron-positron beam incident on a liquid hydrogen target and detecting the scattered particles in the Jefferson Lab CLAS detector. This novel technique allowed us to cover a wide range in virtual photon polarization (epsilon) and momentummore » transfer (Q2) simultaneously, as well as to cancel luminosity-related systematic errors. The cross section ratio increases with decreasing ε at Q2=1.45 GeV2. This measurement is consistent with the size of the form factor discrepancy at Q2≈1.75 GeV2 and with hadronic calculations including nucleon and Delta intermediate states, which have been shown to resolve the discrepancy up to 2-3 GeV2.« less
NASA Technical Reports Server (NTRS)
Bracalente, E. M.; Sweet, J. L.
1984-01-01
The normalized radar cross section (NRCS) signature of the Amazon rain forest was SEASAT scatterometer data. Statistics of the measured (NRCS) values were determined from multiple orbit passes for three local time periods. Plots of mean normalized radar cross section, dB against incidence angle as a function of beam and polarization show that less than 0.3 dB relative bias exists between all beams over a range of incidence angle from 30 deg to 53 deg. The backscattered measurements analyzed show the Amazon rain forest to be relatively homogeneous, azimuthally isotropic and insensitive to polarization. The return from the rain forest target appears relatively consistent and stable, except for the small diurnal variation (0.75 dB) that occurs at sunrise. Because of the relative stability of the rain forest target and the scatterometer instrument, the response of versus incidence angle was able to detect errors in the estimated yaw altitude angle. Also, small instrument gain biases in some of the processing channels were detected. This led to the development of an improved NRCS algorithm, which uses a more accurate method for estimating the system noise power.
Charge equilibrium and radiation of low-energy cosmic rays passing through interstellar medium
NASA Technical Reports Server (NTRS)
Rule, D. W.; Omidvar, K.
1979-01-01
The charge equilibrium and radiation of an oxygen and an iron beam in the MeV per nucleon energy range, representing a typical beam of low-energy cosmic rays passing through the interstellar medium, are considered. Electron loss of the beam has been taken into account by means of the first Born approximation, allowing for the target atom to remain unexcited or to be excited to all possible states. Electron-capture cross sections have been calculated by means of the scaled Oppenheimer-Brinkman-Kramers approximation, taking into account all atomic shells of the target atoms and capture into all excited states of the projectile. The capture and loss cross sections are found to be within 20%-30% of the existing experimental values for most of the cases considered. Radiation of the beam due to electron capture into the excited states of the ion, collisional excitation, and collisional inner-shell ionization, taking into account the fluorescence yield of the ions, has been considered. Effective X-ray production cross sections and multiplicities for the most energetic X-ray lines emitted by the Fe and O beams have been calculated, and error estimates made for the results.
Electron Stark Broadening Database for Atomic N, O, and C Lines
NASA Technical Reports Server (NTRS)
Liu, Yen; Yao, Winifred M.; Wray, Alan A.; Carbon, Duane F.
2012-01-01
A database for efficiently computing the electron Stark broadening line widths for atomic N, O, and C lines is constructed. The line width is expressed in terms of the electron number density and electronatom scattering cross sections based on the Baranger impact theory. The state-to-state cross sections are computed using the semiclassical approximation, in which the atom is treated quantum mechanically whereas the motion of the free electron follows a classical trajectory. These state-to-state cross sections are calculated based on newly compiled line lists. Each atomic line list consists of a careful merger of NIST, Vanderbilt, and TOPbase line datasets from wavelength 50 nm to 50 micrometers covering the VUV to IR spectral regions. There are over 10,000 lines in each atomic line list. The widths for each line are computed at 13 electron temperatures between 1,000 K 50,000 K. A linear least squares method using a four-term fractional power series is then employed to obtain an analytical fit for each line-width variation as a function of the electron temperature. The maximum L2 error of the analytic fits for all lines in our line lists is about 5%.
Towards a Resolution of the Proton Form Factor Problem: New Electron and Positron Scattering Data
Adikaram, D.; Rimal, D.; Weinstein, L. B.; ...
2015-02-10
There is a significant discrepancy between the values of the proton electric form factor, GpE, extracted using unpolarized and polarized electron scattering. Calculations predict that small two-photon exchange (TPE) contributions can significantly affect the extraction of GpE from the unpolarized electron-proton cross sections. We determined the TPE contribution by measuring the ratio of positron-proton to electron-proton elastic scattering cross sections using a simultaneous, tertiary electron-positron beam incident on a liquid hydrogen target and detecting the scattered particles in the Jefferson Lab CLAS detector. This novel technique allowed us to cover a wide range in virtual photon polarization (epsilon) and momentummore » transfer (Q2) simultaneously, as well as to cancel luminosity-related systematic errors. The cross section ratio increases with decreasing ε at Q2=1.45 GeV2. This measurement is consistent with the size of the form factor discrepancy at Q2≈1.75 GeV2 and with hadronic calculations including nucleon and Delta intermediate states, which have been shown to resolve the discrepancy up to 2-3 GeV2.« less
Towards a resolution of the proton form factor problem: new electron and positron scattering data.
Adikaram, D; Rimal, D; Weinstein, L B; Raue, B; Khetarpal, P; Bennett, R P; Arrington, J; Brooks, W K; Adhikari, K P; Afanasev, A V; Amaryan, M J; Anderson, M D; Anefalos Pereira, S; Avakian, H; Ball, J; Battaglieri, M; Bedlinskiy, I; Biselli, A S; Bono, J; Boiarinov, S; Briscoe, W J; Burkert, V D; Carman, D S; Careccia, S; Celentano, A; Chandavar, S; Charles, G; Colaneri, L; Cole, P L; Contalbrigo, M; Crede, V; D'Angelo, A; Dashyan, N; De Vita, R; De Sanctis, E; Deur, A; Djalali, C; Dodge, G E; Dupre, R; Egiyan, H; El Alaoui, A; El Fassi, L; Elouadrhiri, L; Eugenio, P; Fedotov, G; Fegan, S; Filippi, A; Fleming, J A; Fradi, A; Garillon, B; Gilfoyle, G P; Giovanetti, K L; Girod, F X; Goetz, J T; Gohn, W; Golovatch, E; Gothe, R W; Griffioen, K A; Guegan, B; Guidal, M; Guo, L; Hafidi, K; Hakobyan, H; Hanretty, C; Harrison, N; Hattawy, M; Hicks, K; Holtrop, M; Hughes, S M; Hyde, C E; Ilieva, Y; Ireland, D G; Ishkhanov, B S; Jenkins, D; Jiang, H; Jo, H S; Joo, K; Joosten, S; Kalantarians, N; Keller, D; Khandaker, M; Kim, A; Kim, W; Klein, A; Klein, F J; Koirala, S; Kubarovsky, V; Kuhn, S E; Livingston, K; Lu, H Y; MacGregor, I J D; Markov, N; Mattione, P; Mayer, M; McKinnon, B; Mestayer, M D; Meyer, C A; Mirazita, M; Mokeev, V; Montgomery, R A; Moody, C I; Moutarde, H; Movsisyan, A; Camacho, C Munoz; Nadel-Turonski, P; Niccolai, S; Niculescu, G; Osipenko, M; Ostrovidov, A I; Park, K; Pasyuk, E; Peña, C; Pisano, S; Pogorelko, O; Price, J W; Procureur, S; Prok, Y; Protopopescu, D; Puckett, A J R; Ripani, M; Rizzo, A; Rosner, G; Rossi, P; Roy, P; Sabatié, F; Salgado, C; Schott, D; Schumacher, R A; Seder, E; Sharabian, Y G; Simonyan, A; Skorodumina, I; Smith, E S; Smith, G D; Sober, D I; Sokhan, D; Sparveris, N; Stepanyan, S; Stoler, P; Strauch, S; Sytnik, V; Taiuti, M; Tian, Ye; Trivedi, A; Ungaro, M; Voskanyan, H; Voutier, E; Walford, N K; Watts, D P; Wei, X; Wood, M H; Zachariou, N; Zana, L; Zhang, J; Zhao, Z W; Zonta, I
2015-02-13
There is a significant discrepancy between the values of the proton electric form factor, G(E)(p), extracted using unpolarized and polarized electron scattering. Calculations predict that small two-photon exchange (TPE) contributions can significantly affect the extraction of G(E)(p) from the unpolarized electron-proton cross sections. We determined the TPE contribution by measuring the ratio of positron-proton to electron-proton elastic scattering cross sections using a simultaneous, tertiary electron-positron beam incident on a liquid hydrogen target and detecting the scattered particles in the Jefferson Lab CLAS detector. This novel technique allowed us to cover a wide range in virtual photon polarization (ϵ) and momentum transfer (Q(2)) simultaneously, as well as to cancel luminosity-related systematic errors. The cross section ratio increases with decreasing ϵ at Q(2)=1.45 GeV(2). This measurement is consistent with the size of the form factor discrepancy at Q(2)≈1.75 GeV(2) and with hadronic calculations including nucleon and Δ intermediate states, which have been shown to resolve the discrepancy up to 2-3 GeV(2).
Valente, Matthew J.; MacKinnon, David P.
2017-01-01
Models to assess mediation in the pretest-posttest control group design are understudied in the behavioral sciences even though it is the design of choice for evaluating experimental manipulations. The paper provides analytical comparisons of the four most commonly used models used to estimate the mediated effect in this design: Analysis of Covariance (ANCOVA), difference score, residualized change score, and cross-sectional model. Each of these models are fitted using a Latent Change Score specification and a simulation study assessed bias, Type I error, power, and confidence interval coverage of the four models. All but the ANCOVA model make stringent assumptions about the stability and cross-lagged relations of the mediator and outcome that may not be plausible in real-world applications. When these assumptions do not hold, Type I error and statistical power results suggest that only the ANCOVA model has good performance. The four models are applied to an empirical example. PMID:28845097
Valente, Matthew J; MacKinnon, David P
2017-01-01
Models to assess mediation in the pretest-posttest control group design are understudied in the behavioral sciences even though it is the design of choice for evaluating experimental manipulations. The paper provides analytical comparisons of the four most commonly used models used to estimate the mediated effect in this design: Analysis of Covariance (ANCOVA), difference score, residualized change score, and cross-sectional model. Each of these models are fitted using a Latent Change Score specification and a simulation study assessed bias, Type I error, power, and confidence interval coverage of the four models. All but the ANCOVA model make stringent assumptions about the stability and cross-lagged relations of the mediator and outcome that may not be plausible in real-world applications. When these assumptions do not hold, Type I error and statistical power results suggest that only the ANCOVA model has good performance. The four models are applied to an empirical example.
Khorasani, Fahimeh; Beigi, Marjan
2017-01-01
Recently, evaluation and accreditation system of hospitals has had a special emphasis on reporting malpractices and sharing errors or lessons learnt from errors, but still due to lack of promotion of systematic approach for solving problems from the same system, this issue has remained unattended. This study was conducted to determine the effective factors for reporting medical errors among midwives. This project was a descriptive cross-sectional observational study. Data gathering tools were a standard checklist and two researcher-made questionnaires. Sampling for this study was conducted from all the midwives who worked at teaching hospitals affiliated to Isfahan University of Medical Sciences through census method (convenient) and lasted for 3 months. Data were analyzed using descriptive and inferential statistics through SPSS 16. Results showed that 79.1% of the staff reported errors and the highest rate of errors was in the process of patients' tests. In this study, the mean score of midwives' knowledge about the errors was 79.1 and the mean score of their attitude toward reporting errors was 70.4. There was a direct relation between the score of errors' knowledge and attitude in the midwifery staff and reporting errors. Based on the results of this study about the appropriate knowledge and attitude of midwifery staff regarding errors and action toward reporting them, it is recommended to strengthen the system when it comes to errors and hospitals risks.
Classification based upon gene expression data: bias and precision of error rates.
Wood, Ian A; Visscher, Peter M; Mengersen, Kerrie L
2007-06-01
Gene expression data offer a large number of potentially useful predictors for the classification of tissue samples into classes, such as diseased and non-diseased. The predictive error rate of classifiers can be estimated using methods such as cross-validation. We have investigated issues of interpretation and potential bias in the reporting of error rate estimates. The issues considered here are optimization and selection biases, sampling effects, measures of misclassification rate, baseline error rates, two-level external cross-validation and a novel proposal for detection of bias using the permutation mean. Reporting an optimal estimated error rate incurs an optimization bias. Downward bias of 3-5% was found in an existing study of classification based on gene expression data and may be endemic in similar studies. Using a simulated non-informative dataset and two example datasets from existing studies, we show how bias can be detected through the use of label permutations and avoided using two-level external cross-validation. Some studies avoid optimization bias by using single-level cross-validation and a test set, but error rates can be more accurately estimated via two-level cross-validation. In addition to estimating the simple overall error rate, we recommend reporting class error rates plus where possible the conditional risk incorporating prior class probabilities and a misclassification cost matrix. We also describe baseline error rates derived from three trivial classifiers which ignore the predictors. R code which implements two-level external cross-validation with the PAMR package, experiment code, dataset details and additional figures are freely available for non-commercial use from http://www.maths.qut.edu.au/profiles/wood/permr.jsp
Luo, Y.; Xia, J.; Liu, J.; Xu, Y.; Liu, Q.
2008-01-01
Multichannel Analysis of Surface Waves utilizes a multichannel recording system to estimate near-surface shear (S)-wave velocities from high-frequency Rayleigh waves. A pseudo-2D S-wave velocity (vS) section is constructed by aligning 1D models at the midpoint of each receiver spread and using a spatial interpolation scheme. The horizontal resolution of the section is therefore most influenced by the receiver spread length and the source interval. The receiver spread length sets the theoretical lower limit and any vS structure with its lateral dimension smaller than this length will not be properly resolved in the final vS section. A source interval smaller than the spread length will not improve the horizontal resolution because spatial smearing has already been introduced by the receiver spread. In this paper, we first analyze the horizontal resolution of a pair of synthetic traces. Resolution analysis shows that (1) a pair of traces with a smaller receiver spacing achieves higher horizontal resolution of inverted S-wave velocities but results in a larger relative error; (2) the relative error of the phase velocity at a high frequency is smaller than at a low frequency; and (3) a relative error of the inverted S-wave velocity is affected by the signal-to-noise ratio of data. These results provide us with a guideline to balance the trade-off between receiver spacing (horizontal resolution) and accuracy of the inverted S-wave velocity. We then present a scheme to generate a pseudo-2D S-wave velocity section with high horizontal resolution using multichannel records by inverting high-frequency surface-wave dispersion curves calculated through cross-correlation combined with a phase-shift scanning method. This method chooses only a pair of consecutive traces within a shot gather to calculate a dispersion curve. We finally invert surface-wave dispersion curves of synthetic and real-world data. Inversion results of both synthetic and real-world data demonstrate that inverting high-frequency surface-wave dispersion curves - by a pair of traces through cross-correlation with phase-shift scanning method and with the damped least-square method and the singular-value decomposition technique - can feasibly achieve a reliable pseudo-2D S-wave velocity section with relatively high horizontal resolution. ?? 2008 Elsevier B.V. All rights reserved.
Human Error Analysis in a Permit to Work System: A Case Study in a Chemical Plant
Jahangiri, Mehdi; Hoboubi, Naser; Rostamabadi, Akbar; Keshavarzi, Sareh; Hosseini, Ali Akbar
2015-01-01
Background A permit to work (PTW) is a formal written system to control certain types of work which are identified as potentially hazardous. However, human error in PTW processes can lead to an accident. Methods This cross-sectional, descriptive study was conducted to estimate the probability of human errors in PTW processes in a chemical plant in Iran. In the first stage, through interviewing the personnel and studying the procedure in the plant, the PTW process was analyzed using the hierarchical task analysis technique. In doing so, PTW was considered as a goal and detailed tasks to achieve the goal were analyzed. In the next step, the standardized plant analysis risk-human (SPAR-H) reliability analysis method was applied for estimation of human error probability. Results The mean probability of human error in the PTW system was estimated to be 0.11. The highest probability of human error in the PTW process was related to flammable gas testing (50.7%). Conclusion The SPAR-H method applied in this study could analyze and quantify the potential human errors and extract the required measures for reducing the error probabilities in PTW system. Some suggestions to reduce the likelihood of errors, especially in the field of modifying the performance shaping factors and dependencies among tasks are provided. PMID:27014485
A description of medication errors reported by pharmacists in a neonatal intensive care unit.
Pawluk, Shane; Jaam, Myriam; Hazi, Fatima; Al Hail, Moza Sulaiman; El Kassem, Wessam; Khalifa, Hanan; Thomas, Binny; Abdul Rouf, Pallivalappila
2017-02-01
Background Patients in the Neonatal Intensive Care Unit (NICU) are at an increased risk for medication errors. Objective The objective of this study is to describe the nature and setting of medication errors occurring in patients admitted to an NICU in Qatar based on a standard electronic system reported by pharmacists. Setting Neonatal intensive care unit, Doha, Qatar. Method This was a retrospective cross-sectional study on medication errors reported electronically by pharmacists in the NICU between January 1, 2014 and April 30, 2015. Main outcome measure Data collected included patient information, and incident details including error category, medications involved, and follow-up completed. Results A total of 201 NICU pharmacists-reported medication errors were submitted during the study period. All reported errors did not reach the patient and did not cause harm. Of the errors reported, 98.5% occurred in the prescribing phase of the medication process with 58.7% being due to calculation errors. Overall, 53 different medications were documented in error reports with the anti-infective agents being the most frequently cited. The majority of incidents indicated that the primary prescriber was contacted and the error was resolved before reaching the next phase of the medication process. Conclusion Medication errors reported by pharmacists occur most frequently in the prescribing phase of the medication process. Our data suggest that error reporting systems need to be specific to the population involved. Special attention should be paid to frequently used medications in the NICU as these were responsible for the greatest numbers of medication errors.
An Improved Neutron Transport Algorithm for HZETRN
NASA Technical Reports Server (NTRS)
Slaba, Tony C.; Blattnig, Steve R.; Clowdsley, Martha S.; Walker, Steven A.; Badavi, Francis F.
2010-01-01
Long term human presence in space requires the inclusion of radiation constraints in mission planning and the design of shielding materials, structures, and vehicles. In this paper, the numerical error associated with energy discretization in HZETRN is addressed. An inadequate numerical integration scheme in the transport algorithm is shown to produce large errors in the low energy portion of the neutron and light ion fluence spectra. It is further shown that the errors result from the narrow energy domain of the neutron elastic cross section spectral distributions, and that an extremely fine energy grid is required to resolve the problem under the current formulation. Two numerical methods are developed to provide adequate resolution in the energy domain and more accurately resolve the neutron elastic interactions. Convergence testing is completed by running the code for various environments and shielding materials with various energy grids to ensure stability of the newly implemented method.
Shi, Joy; Korsiak, Jill; Roth, Daniel E
2018-03-01
We aimed to demonstrate the use of jackknife residuals to take advantage of the longitudinal nature of available growth data in assessing potential biologically implausible values and outliers. Artificial errors were induced in 5% of length, weight, and head circumference measurements, measured on 1211 participants from the Maternal Vitamin D for Infant Growth (MDIG) trial from birth to 24 months of age. Each child's sex- and age-standardized z-score or raw measurements were regressed as a function of age in child-specific models. Each error responsible for a biologically implausible decrease between a consecutive pair of measurements was identified based on the higher of the two absolute values of jackknife residuals in each pair. In further analyses, outliers were identified as those values beyond fixed cutoffs of the jackknife residuals (e.g., greater than +5 or less than -5 in primary analyses). Kappa, sensitivity, and specificity were calculated over 1000 simulations to assess the ability of the jackknife residual method to detect induced errors and to compare these methods with the use of conditional growth percentiles and conventional cross-sectional methods. Among the induced errors that resulted in a biologically implausible decrease in measurement between two consecutive values, the jackknife residual method identified the correct value in 84.3%-91.5% of these instances when applied to the sex- and age-standardized z-scores, with kappa values ranging from 0.685 to 0.795. Sensitivity and specificity of the jackknife method were higher than those of the conditional growth percentile method, but specificity was lower than for conventional cross-sectional methods. Using jackknife residuals provides a simple method to identify biologically implausible values and outliers in longitudinal child growth data sets in which each child contributes at least 4 serial measurements. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.
Modeling the field of a passive scalar in a nonisothermal turbulent plane gas jet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abrashin, V.N.; Barykin, V.N.; Martynenko, O.G.
The problem of the distribution of thermal characteristics in a plane nonisothermal turbulent gas jet in the case of large Reynolds numbers and a small temperature difference, allowing heat to be regarded as a passive impurity, is solved in the range of jet cross sections 20-100 caliber by a second-order correlational model of turbulence and an effective numerical algorithm. Analysis of the results show that the model allows computational data in good agreement with experiment to be obtained in the range of jet cross section 20-100 diameters. The relative error in determining the maximum values of the functions is 3-10%more » for the dynamic characteristics while the mean temperature and its mean square pulsations are determined with an accuracy of 5-10%; the corresponding figures for the thermal characteristics are 5-15% and 5-10%.« less
On proton excitation of forbidden lines in positive ions
NASA Astrophysics Data System (ADS)
Burgess, Alan; Tully, John A.
2005-08-01
The semi-classical impact parameter approximations used by Bahcall and Wolf and by Bely and Faucher, for proton excitation of electric quadrupole transitions in positive ions, both fail at high energies, giving cross sections which do not fall off correctly as constant/E. This is in contrast with the pioneering example of Seaton for Fe+13 and of Reid and Schwarz for S+3, both of whom achieve the correct functional form, but do not ensure the correct constant of proportionality. By combining the Born and semi-classical approximations one can obtain cross sections which have the full correct behaviour as E → ∞, and hence, rate coefficients which have the correct high temperature behaviour (~C/T1/2 with the correct value of C). We provide a computer program for calculating these. An error in Faucher's derivation of the Born formula is also discussed.
Resonance treatment using pin-based pointwise energy slowing-down method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Sooyoung, E-mail: csy0321@unist.ac.kr; Lee, Changho, E-mail: clee@anl.gov; Lee, Deokjung, E-mail: deokjung@unist.ac.kr
A new resonance self-shielding method using a pointwise energy solution has been developed to overcome the drawbacks of the equivalence theory. The equivalence theory uses a crude resonance scattering source approximation, and assumes a spatially constant scattering source distribution inside a fuel pellet. These two assumptions cause a significant error, in that they overestimate the multi-group effective cross sections, especially for {sup 238}U. The new resonance self-shielding method solves pointwise energy slowing-down equations with a sub-divided fuel rod. The method adopts a shadowing effect correction factor and fictitious moderator material to model a realistic pointwise energy solution. The slowing-down solutionmore » is used to generate the multi-group cross section. With various light water reactor problems, it was demonstrated that the new resonance self-shielding method significantly improved accuracy in the reactor parameter calculation with no compromise in computation time, compared to the equivalence theory.« less
Ultraviolet absorption spectrum of HOCl
NASA Technical Reports Server (NTRS)
Burkholder, James B.
1993-01-01
The room temperature UV absorption spectrum of HOCl was measured over the wavelength range 200 to 380 nm with a diode array spectrometer. The absorption spectrum was identified from UV absorption spectra recorded following UV photolysis of equilibrium mixtures of Cl2O/H2O/HOCl. The HOCl spectrum is continuous with a maximum at 242 nm and a secondary peak at 304 nm. The measured absorption cross section at 242 nm was (2.1 +/- 0.3) x 10 exp -19/sq cm (2 sigma error limits). These results are in excellent agreement with the work of Knauth et al. (1979) but in poor agreement with the more recent measurements of Mishalanie et al. (1986) and Permien et al. (1988). An HOCl nu2 infrared band intensity of 230 +/- 35/sq cm atm was determined based on this UV absorption cross section. The present results are compared with these previous measurements and the discrepancies are discussed.
Plans for a sensitivity analysis of bridge-scour computations
Dunn, David D.; Smith, Peter N.
1993-01-01
Plans for an analysis of the sensitivity of Level 2 bridge-scour computations are described. Cross-section data from 15 bridge sites in Texas are modified to reflect four levels of field effort ranging from no field surveys to complete surveys. Data from United States Geological Survey (USGS) topographic maps will be used to supplement incomplete field surveys. The cross sections are used to compute the water-surface profile through each bridge for several T-year recurrence-interval design discharges. The effect of determining the downstream energy grade-line slope from topographic maps is investigated by systematically varying the starting slope of each profile. The water-surface profile analyses are then used to compute potential scour resulting from each of the design discharges. The planned results will be presented in the form of exceedance-probability versus scour-depth plots with the maximum and minimum scour depths at each T-year discharge presented as error bars.
Big bang nucleosynthesis revisited via Trojan Horse method measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pizzone, R. G.; Spartá, R.; Spitaleri, C.
Nuclear reaction rates are among the most important input for understanding primordial nucleosynthesis and, therefore, for a quantitative description of the early universe. An up-to-date compilation of direct cross-sections of {sup 2}H(d, p){sup 3}H, {sup 2}H(d, n){sup 3}He, {sup 7}Li(p, α){sup 4}He, and {sup 3}He(d, p){sup 4}He reactions is given. These are among the most uncertain cross-sections used and input for big bang nucleosynthesis calculations. Their measurements through the Trojan Horse method are also reviewed and compared with direct data. The reaction rates and the corresponding recommended errors in this work were used as input for primordial nucleosynthesis calculations tomore » evaluate their impact on the {sup 2}H, {sup 3,4}He, and {sup 7}Li primordial abundances, which are then compared with observations.« less
Coherent vector meson photoproduction from deuterium at intermediate energies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rogers, T.C.; Strikman, M.I.; Sargsian, M.M.
2006-04-15
We analyze the cross section for vector meson photoproduction off a deuteron for the intermediate range of photon energies starting at a few giga-electron-volts above the threshold and higher. We reproduce the steps in the derivation of the conventional nonrelativistic Glauber expression based on an effective diagrammatic method while making corrections for Fermi motion and intermediate-energy kinematic effects. We show that, for intermediate-energy vector meson production, the usual Glauber factorization breaks down, and we derive corrections to the usual Glauber method to linear order in longitudinal nucleon momentum. The purpose of our analysis is to establish methods for probing interestingmore » physics in the production mechanism for {phi} mesons and heavier vector mesons. We demonstrate how neglecting the breakdown of Glauber factorization can lead to errors in measurements of basic cross sections extracted from nuclear data.« less
[Failure mode and effects analysis on computerized drug prescriptions].
Paredes-Atenciano, J A; Roldán-Aviña, J P; González-García, Mercedes; Blanco-Sánchez, M C; Pinto-Melero, M A; Pérez-Ramírez, C; Calvo Rubio-Burgos, Miguel; Osuna-Navarro, F J; Jurado-Carmona, A M
2015-01-01
To identify and analyze errors in drug prescriptions of patients treated in a "high resolution" hospital by applying a Failure mode and effects analysis (FMEA).Material and methods A multidisciplinary group of medical specialties and nursing analyzed medical records where drug prescriptions were held in free text format. An FMEA was developed in which the risk priority index (RPI) was obtained from a cross-sectional observational study using an audit of the medical records, carried out in 2 phases: 1) Pre-intervention testing, and (2) evaluation of improvement actions after the first analysis. An audit sample size of 679 medical records from a total of 2,096 patients was calculated using stratified sampling and random selection of clinical events. Prescription errors decreased by 22.2% in the second phase. FMEA showed a greater RPI in "unspecified route of administration" and "dosage unspecified", with no significant decreases observed in the second phase, although it did detect, "incorrect dosing time", "contraindication due to drug allergy", "wrong patient" or "duplicate prescription", which resulted in the improvement of prescriptions. Drug prescription errors have been identified and analyzed by FMEA methodology, improving the clinical safety of these prescriptions. This tool allows updates of electronic prescribing to be monitored. To avoid such errors would require the mandatory completion of all sections of a prescription. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.
Kiymaz, Dilek; Koç, Zeliha
2018-03-01
To determine individual and professional factors affecting the tendency of emergency unit nurses to make medical errors and their attitudes towards these errors in Turkey. Compared with other units, the emergency unit is an environment where there is an increased tendency for making medical errors due to its intensive and rapid pace, noise and complex and dynamic structure. A descriptive cross-sectional study. The study was carried out from 25 July 2014-16 September 2015 with the participation of 284 nurses who volunteered to take part in the study. Data were gathered using the data collection survey for nurses, the Medical Error Tendency Scale and the Medical Error Attitude Scale. It was determined that 40.1% of the nurses previously witnessed medical errors, 19.4% made a medical error in the last year, 17.6% of medical errors were caused by medication errors where the wrong medication was administered in the wrong dose, and none of the nurses filled out a case report form about the medical errors they made. Regarding the factors that caused medical errors in the emergency unit, 91.2% of the nurses stated excessive workload as a cause; 85.1% stated an insufficient number of nurses; and 75.4% stated fatigue, exhaustion and burnout. The study showed that nurses who loved their job were satisfied with their unit and who always worked during day shifts had a lower medical error tendency. It is suggested to consider the following actions: increase awareness about medical errors, organise training to reduce errors in medication administration, develop procedures and protocols specific to the emergency unit health care and create an environment which is not punitive wherein nurses can safely report medical errors. © 2017 John Wiley & Sons Ltd.
Amori, Renee E; Pittas, Anastassios G; Siegel, Richard D; Kumar, Sanjaya; Chen, Jack S; Karnam, Suneel; Golden, Sherita H; Salem, Deeb N
2008-01-01
To describe characteristics of inpatient medical errors involving hypoglycemic medications and their impact on patient care. We conducted a cross-sectional analysis of medical errors and associated adverse events voluntarily reported by hospital employees and staff in 21 nonprofit, nonfederal health-care organizations in the United States that implemented a Web-based electronic error-reporting system (e-ERS) between August 1, 2000, and December 31, 2005. Persons reporting the errors determined the level of impact on patient care. The median duration of e-ERS use was 3.1 years, and 2,598 inpatient error reports involved insulin or orally administered hypoglycemic agents. Nursing staff provided 59% of the reports; physicians reported <2%. Approximately two-thirds of the errors (1,693 of 2,598) reached the patient. Errors that caused temporary harm necessitating major treatment or that caused permanent harm accounted for 1.5% of reports (40 of 2,598). Insulin was involved in 82% of reports, and orally administered hypoglycemic agents were involved in 18% of all reports (473 of 2,598). Sulfonylureas were implicated in 51.8% of reports involving oral hypoglycemic agents (9.4% of all reports). An e-ERS provides an accessible venue for reporting and tracking inpatient medical errors involving glucose-lowering medications. Results are limited by potential underreporting of events, particularly by physicians, and variations in the reporter perception of patient harm.
Teamwork and clinical error reporting among nurses in Korean hospitals.
Hwang, Jee-In; Ahn, Jeonghoon
2015-03-01
To examine levels of teamwork and its relationships with clinical error reporting among Korean hospital nurses. The study employed a cross-sectional survey design. We distributed a questionnaire to 674 nurses in two teaching hospitals in Korea. The questionnaire included items on teamwork and the reporting of clinical errors. We measured teamwork using the Teamwork Perceptions Questionnaire, which has five subscales including team structure, leadership, situation monitoring, mutual support, and communication. Using logistic regression analysis, we determined the relationships between teamwork and error reporting. The response rate was 85.5%. The mean score of teamwork was 3.5 out of 5. At the subscale level, mutual support was rated highest, while leadership was rated lowest. Of the participating nurses, 522 responded that they had experienced at least one clinical error in the last 6 months. Among those, only 53.0% responded that they always or usually reported clinical errors to their managers and/or the patient safety department. Teamwork was significantly associated with better error reporting. Specifically, nurses with a higher team communication score were more likely to report clinical errors to their managers and the patient safety department (odds ratio = 1.82, 95% confidence intervals [1.05, 3.14]). Teamwork was rated as moderate and was positively associated with nurses' error reporting performance. Hospital executives and nurse managers should make substantial efforts to enhance teamwork, which will contribute to encouraging the reporting of errors and improving patient safety. Copyright © 2015. Published by Elsevier B.V.
Yingyong, Penpimol
2010-11-01
Refractive error is one of the leading causes of visual impairment in children. An analysis of risk factors for refractive error is required to reduce and prevent this common eye disease. To identify the risk factors associated with refractive errors in primary school children (6-12 year old) in Nakhon Pathom province. A population-based cross-sectional analytic study was conducted between October 2008 and September 2009 in Nakhon Pathom. Refractive error, parental refractive status, and hours per week of near activities (studying, reading books, watching television, playing with video games, or working on the computer) were assessed in 377 children who participated in this study. The most common type of refractive error in primary school children was myopia. Myopic children were more likely to have parents with myopia. Children with myopia spend more time at near activities. The multivariate odds ratio (95% confidence interval)for two myopic parents was 6.37 (2.26-17.78) and for each diopter-hour per week of near work was 1.019 (1.005-1.033). Multivariate logistic regression models show no confounding effects between parental myopia and near work suggesting that each factor has an independent association with myopia. Statistical analysis by logistic regression revealed that family history of refractive error and hours of near-work were significantly associated with refractive error in primary school children.
Patient safety awareness among Undergraduate Medical Students in Pakistani Medical School.
Kamran, Rizwana; Bari, Attia; Khan, Rehan Ahmed; Al-Eraky, Mohamed
2018-01-01
To measure the level of awareness of patient safety among undergraduate medical students in Pakistani Medical School and to find the difference with respect to gender and prior experience with medical error. This cross-sectional study was conducted at the University of Lahore (UOL), Pakistan from January to March 2017, and comprised final year medical students. Data was collected using a questionnaire 'APSQ- III' on 7 point Likert scale. Eight questions were reverse coded. Survey was anonymous. SPSS package 20 was used for statistical analysis. Questionnaire was filled by 122 students, with 81% response rate. The best score 6.17 was given for the 'team functioning', followed by 6.04 for 'long working hours as a cause of medical error'. The domains regarding involvement of patient, confidence to report medical errors and role of training and learning on patient safety scored high in the agreed range of >5. Reverse coded questions about 'professional incompetence as an error cause' and 'disclosure of errors' showed negative perception. No significant differences of perceptions were found with respect to gender and prior experience with medical error (p= >0.05). Undergraduate medical students at UOL had a positive attitude towards patient safety. However, there were misconceptions about causes of medical errors and error disclosure among students and patient safety education needs to be incorporated in medical curriculum of Pakistan.
Effects of Shame and Guilt on Error Reporting Among Obstetric Clinicians.
Zabari, Mara Lynne; Southern, Nancy L
2018-04-17
To understand how the experiences of shame and guilt, coupled with organizational factors, affect error reporting by obstetric clinicians. Descriptive cross-sectional. A sample of 84 obstetric clinicians from three maternity units in Washington State. In this quantitative inquiry, a variant of the Test of Self-Conscious Affect was used to measure proneness to guilt and shame. In addition, we developed questions to assess attitudes regarding concerns about damaging one's reputation if an error was reported and the choice to keep an error to oneself. Both assessments were analyzed separately and then correlated to identify relationships between constructs. Interviews were used to identify organizational factors that affect error reporting. As a group, mean scores indicated that obstetric clinicians would not choose to keep errors to themselves. However, bivariate correlations showed that proneness to shame was positively correlated to concerns about one's reputation if an error was reported, and proneness to guilt was negatively correlated with keeping errors to oneself. Interview data analysis showed that Past Experience with Responses to Errors, Management and Leadership Styles, Professional Hierarchy, and Relationships With Colleagues were influential factors in error reporting. Although obstetric clinicians want to report errors, their decisions to report are influenced by their proneness to guilt and shame and perceptions of the degree to which organizational factors facilitate or create barriers to restore their self-images. Findings underscore the influence of the organizational context on clinicians' decisions to report errors. Copyright © 2018 AWHONN, the Association of Women’s Health, Obstetric and Neonatal Nurses. Published by Elsevier Inc. All rights reserved.
Mostafaei, Davoud; Barati Marnani, Ahmad; Mosavi Esfahani, Haleh; Estebsari, Fatemeh; Shahzaidi, Shiva; Jamshidi, Ensiyeh; Aghamiri, Seyed Samad
2014-10-01
About one third of unwanted reported medication consequences are due to medication errors, resulting in one-fifth of hospital injuries. The aim of this study was determined formal and informal medication errors of nurses and the level of importance of factors in refusal to report medication errors among nurses. The cross-sectional study was done on the nursing staff of Shohada Tajrish Hospital, Tehran, Iran in 2012. The data was gathered through a questionnaire, made by the researchers. The questionnaires' face and content validity was confirmed by experts and for measuring its reliability test-retest was used. The data was analyzed by descriptive statistics. We used SPSS for related statistical analyses. The most important factors in refusal to report medication errors respectively were: lack of medication error recording and reporting system in the hospital (3.3%), non-significant error reporting to hospital authorities and lack of appropriate feedback (3.1%), and lack of a clear definition for a medication error (3%). There were both formal and informal reporting of medication errors in this study. Factors pertaining to management in hospitals as well as the fear of the consequences of reporting are two broad fields among the factors that make nurses not report their medication errors. In this regard, providing enough education to nurses, boosting the job security for nurses, management support and revising related processes and definitions are some factors that can help decreasing medication errors and increasing their report in case of occurrence.
Prevalence and pattern of prescription errors in a Nigerian kidney hospital.
Babatunde, Kehinde M; Akinbodewa, Akinwumi A; Akinboye, Ayodele O; Adejumo, Ademola O
2016-12-01
To determine (i) the prevalence and pattern of prescription errors in our Centre and, (ii) appraise pharmacists' intervention and correction of identified prescription errors. A descriptive, single blinded cross-sectional study. Kidney Care Centre is a public Specialist hospital. The monthly patient load averages 60 General Out-patient cases and 17.4 in-patients. A total of 31 medical doctors (comprising of 2 Consultant Nephrologists, 15 Medical Officers, 14 House Officers), 40 nurses and 24 ward assistants participated in the study. One pharmacist runs the daily call schedule. Prescribers were blinded to the study. Prescriptions containing only galenicals were excluded. An error detection mechanism was set up to identify and correct prescription errors. Life-threatening prescriptions were discussed with the Quality Assurance Team of the Centre who conveyed such errors to the prescriber without revealing the on-going study. Prevalence of prescription errors, pattern of prescription errors, pharmacist's intervention. A total of 2,660 (75.0%) combined prescription errors were found to have one form of error or the other; illegitimacy 1,388 (52.18%), omission 1,221(45.90%), wrong dose 51(1.92%) and no error of style was detected. Life-threatening errors were low (1.1-2.2%). Errors were found more commonly among junior doctors and non-medical doctors. Only 56 (1.6%) of the errors were detected and corrected during the process of dispensing. Prescription errors related to illegitimacy and omissions were highly prevalent. There is a need to improve on patient-to-healthcare giver ratio. A medication quality assurance unit is needed in our hospitals. No financial support was received by any of the authors for this study.
Participation in the TOMS Science Team
NASA Technical Reports Server (NTRS)
Chance, Kelly; Hilsenrath, Ernest (Technical Monitor)
2002-01-01
Because of the nominal funding provided by this grant, some of the relevant research is partially funded by other sources. Research performed for this funding period included the following items: We have investigated errors in TOMS ozone measurements caused by the uncertainty in wavelength calibration, coupled with the ozone cross sections in the Huggins bands and their temperature dependence. Preliminary results show that 0.1 nm uncertainty in TOMS wavelength calibration at the ozone active wavelengths corresponds to approx. 1% systematic error in O3, and thus potential 1% biases among ozone trends from the various TOMS instruments. This conclusion will be revised for absolute O3 Measurements as cross sections are further investigated for inclusion in the HITRAN database at the SAO, but the potential for relative errors remains. In order to aid further comparisons among TOMS and GOME ozone measurements, we have implemented our method of direct fitting of GOME radiances (BOAS) for O3, and now obtain the best fitting precision to date for GOME O3 Columns. This will aid in future comparisons of the actual quantities measured and fitted for the two instrument types. We have made comparisons between GOME ICFA cloud fraction and cloud fraction determined from GOME data using the Ring effect in the Ca II lines. There is a strong correlation, as expected, but there are substantial systematic biases between the determinations. This study will be refined in the near future using the recently-developed GOME Cloud Retrieval Algorithm (GOMECAT). We have improved the SAO Ring effect determination to include better convolution with instrument transfer functions and inclusion of interferences by atmospheric absorbers (e.g., O3). This has been made available to the general community.
Weaknesses in the reporting of cross-sectional studies according to the STROBE statement
Malaga, German; Miranda, Jaime
2015-01-01
Introduction: The inadequate reporting of cross-sectional studies, as in the case of the prevalence of metabolic syndrome, could cause problems in the synthesis of new evidence and lead to errors in the formulation of public policies. Objective: To evaluate the reporting quality of the articles regarding metabolic syndrome prevalence in Peruvian adults using the STROBE recommendations. Methods: We conducted a thorough literature search with the terms "Metabolic Syndrome", "Sindrome Metabolico" and "Peru" in MEDLINE/PubMed, LILACS, SciELO, LIPECS and BVS-Peru until December 2014. We selected those who were population-based observational studies with randomized sampling that reported prevalence of metabolic syndrome in adults aged 18 or more of both sexes. Information was analysed through the STROBE score per item and recommendation. Results: Seventeen articles were included in this study. All articles met the recommendations related to the report of the study's rationale, design, and provision of summary measures. The recommendations with the lowest scores were those related to the sensitivity analysis (8%, n= 1/17), participant flowchart (18%, n= 3/17), missing data analysis (24%, n= 4/17), and number of participants in each study phase (24%, n= 4/17). Conclusion: Cross-sectional studies regarding the prevalence of metabolic syndrome in peruvian adults have an inadequate reporting on the methods and results sections. We identified a clear need to improve the quality of such studies. PMID:26848197
Tapia, Jose Carlos; Ruiz, Eloy F; Ponce, Oscar J; Malaga, German; Miranda, Jaime
2015-12-30
The inadequate reporting of cross-sectional studies, as in the case of the prevalence of metabolic syndrome, could cause problems in the synthesis of new evidence and lead to errors in the formulation of public policies. To evaluate the reporting quality of the articles regarding metabolic syndrome prevalence in Peruvian adults using the STROBE recommendations. We conducted a thorough literature search with the terms "Metabolic Syndrome", "Sindrome Metabolico" and "Peru" in MEDLINE/PubMed, LILACS, SciELO, LIPECS and BVS-Peru until December 2014. We selected those who were population-based observational studies with randomized sampling that reported prevalence of metabolic syndrome in adults aged 18 or more of both sexes. Information was analysed through the STROBE score per item and recommendation. Seventeen articles were included in this study. All articles met the recommendations related to the report of the study's rationale, design, and provision of summary measures. The recommendations with the lowest scores were those related to the sensitivity analysis (8%, n= 1/17), participant flowchart (18%, n= 3/17), missing data analysis (24%, n= 4/17), and number of participants in each study phase (24%, n= 4/17). Cross-sectional studies regarding the prevalence of metabolic syndrome in peruvian adults have an inadequate reporting on the methods and results sections. We identified a clear need to improve the quality of such studies.
Martín-Merino, Elisa; Calderón-Larrañaga, Amaia; Hawley, Samuel; Poblador-Plou, Beatriz; Llorente-García, Ana; Petersen, Irene; Prieto-Alhambra, Daniel
2018-01-01
Background Missing data are often an issue in electronic medical records (EMRs) research. However, there are many ways that people deal with missing data in drug safety studies. Aim To compare the risk estimates resulting from different strategies for the handling of missing data in the study of venous thromboembolism (VTE) risk associated with antiosteoporotic medications (AOM). Methods New users of AOM (alendronic acid, other bisphosphonates, strontium ranelate, selective estrogen receptor modulators, teriparatide, or denosumab) aged ≥50 years during 1998–2014 were identified in two Spanish (the Base de datos para la Investigación Farmacoepidemiológica en Atención Primaria [BIFAP] and EpiChron cohort) and one UK (Clinical Practice Research Datalink [CPRD]) EMR. Hazard ratios (HRs) according to AOM (with alendronic acid as reference) were calculated adjusting for VTE risk factors, body mass index (that was missing in 61% of patients included in the three databases), and smoking (that was missing in 23% of patients) in the year of AOM therapy initiation. HRs and standard errors obtained using cross-sectional multiple imputation (MI) (reference method) were compared to complete case (CC) analysis – using only patients with complete data – and longitudinal MI – adding to the cross-sectional MI model the body mass index/smoking values as recorded in the year before and after therapy initiation. Results Overall, 422/95,057 (0.4%), 19/12,688 (0.1%), and 2,051/161,202 (1.3%) VTE cases/participants were seen in BIFAP, EpiChron, and CPRD, respectively. HRs moved from 100.00% underestimation to 40.31% overestimation in CC compared with cross-sectional MI, while longitudinal MI methods provided similar risk estimates compared with cross-sectional MI. Precision for HR improved in cross-sectional MI versus CC by up to 160.28%, while longitudinal MI improved precision (compared with cross-sectional) only minimally (up to 0.80%). Conclusion CC may substantially affect relative risk estimation in EMR-based drug safety studies, since missing data are not often completely at random. Little improvement was seen in these data in terms of power with the inclusion of longitudinal MI compared with cross-sectional MI. The strategy for handling missing data in drug safety studies can have a large impact on both risk estimates and precision.
Martín-Merino, Elisa; Calderón-Larrañaga, Amaia; Hawley, Samuel; Poblador-Plou, Beatriz; Llorente-García, Ana; Petersen, Irene; Prieto-Alhambra, Daniel
2018-01-01
Missing data are often an issue in electronic medical records (EMRs) research. However, there are many ways that people deal with missing data in drug safety studies. To compare the risk estimates resulting from different strategies for the handling of missing data in the study of venous thromboembolism (VTE) risk associated with antiosteoporotic medications (AOM). New users of AOM (alendronic acid, other bisphosphonates, strontium ranelate, selective estrogen receptor modulators, teriparatide, or denosumab) aged ≥50 years during 1998-2014 were identified in two Spanish (the Base de datos para la Investigación Farmacoepidemiológica en Atención Primaria [BIFAP] and EpiChron cohort) and one UK (Clinical Practice Research Datalink [CPRD]) EMR. Hazard ratios (HRs) according to AOM (with alendronic acid as reference) were calculated adjusting for VTE risk factors, body mass index (that was missing in 61% of patients included in the three databases), and smoking (that was missing in 23% of patients) in the year of AOM therapy initiation. HRs and standard errors obtained using cross-sectional multiple imputation (MI) (reference method) were compared to complete case (CC) analysis - using only patients with complete data - and longitudinal MI - adding to the cross-sectional MI model the body mass index/smoking values as recorded in the year before and after therapy initiation. Overall, 422/95,057 (0.4%), 19/12,688 (0.1%), and 2,051/161,202 (1.3%) VTE cases/participants were seen in BIFAP, EpiChron, and CPRD, respectively. HRs moved from 100.00% underestimation to 40.31% overestimation in CC compared with cross-sectional MI, while longitudinal MI methods provided similar risk estimates compared with cross-sectional MI. Precision for HR improved in cross-sectional MI versus CC by up to 160.28%, while longitudinal MI improved precision (compared with cross-sectional) only minimally (up to 0.80%). CC may substantially affect relative risk estimation in EMR-based drug safety studies, since missing data are not often completely at random. Little improvement was seen in these data in terms of power with the inclusion of longitudinal MI compared with cross-sectional MI. The strategy for handling missing data in drug safety studies can have a large impact on both risk estimates and precision.
A High Spectral Resolution Lidar Based on Absorption Filter
NASA Technical Reports Server (NTRS)
Piironen, Paivi
1996-01-01
A High Spectral Resolution Lidar (HSRL) that uses an iodine absorption filter and a tunable, narrow bandwidth Nd:YAG laser is demonstrated. The iodine absorption filter provides better performance than the Fabry-Perot etalon that it replaces. This study presents an instrument design that can be used a the basis for a design of a simple and robust lidar for the measurement of the optical properties of the atmosphere. The HSRL provides calibrated measurements of the optical properties of the atmospheric aerosols. These observations include measurements of aerosol backscatter cross sections, optical depth, backscatter phase function depolarization, and multiple scattering. The errors in the HSRL data are discussed and the effects of different errors on the measured optical parameters are shown.
NASA Technical Reports Server (NTRS)
Sapp, Clyde A.; See, Thomas H.; Zolensky, Michael E.
1992-01-01
During the 3 month deintegration of the LDEF, the M&D SIG generated approximately 5000 digital color stereo image pairs of impact related features from all space exposed surfaces. Currently, these images are being processed at JSC to yield more accurate feature information. Work is currently underway to determine the minimum number of data points necessary to parametrically define impact crater morphologies in order to minimize the man-hour intensive task of tie point selection. Initial attempts at deriving accurate crater depth and diameter measurements from binocular imagery were based on the assumption that the crater geometries were best defined by paraboloid. We made no assumptions regarding the crater depth/diameter ratios but instead allowed each crater to define its own coefficients by performing a least-squares fit based on user-selected tiepoints. Initial test cases resulted in larger errors than desired, so it was decided to test our basic assumptions that the crater geometries could be parametrically defined as paraboloids. The method for testing this assumption was to carefully slice test craters (experimentally produced in an appropriate aluminum alloy) vertically through the center resulting in a readily visible cross-section of the crater geometry. Initially, five separate craters were cross-sectioned in this fashion. A digital image of each cross-section was then created, and the 2-D crater geometry was then hand-digitized to create a table of XY position for each crater. A 2nd order polynomial (parabolic) was fitted to the data using a least-squares approach. The differences between the fit equation and the actual data were fairly significant, and easily large enough to account for the errors found in the 3-D fits. The differences between the curve fit and the actual data were consistent between the caters. This consistency suggested that the differences were due to the fact that a parabola did not sufficiently define the generic crater geometry. Fourth and 6th order equations were then fitted to each crater cross-section, and significantly better estimates of the crater geometry were obtained with each fit. Work is presently underway to determine the best way to make use of this new parametric crater definition.
Consanguinity, endogamy and inborn errors of metabolism in Oman: a cross-sectional study.
Al-Thihli, Khalid; Al-Murshedi, Fathiya; Al-Hashmi, Nadia; Al-Mamari, Watfa; Islam, M Mazharul; Al-Yahyaee, Said A
2014-01-01
The Sultanate of Oman, like many other Arab countries, has relatively high rates of consanguinity. Reports suggest that the incidence of inborn errors of metabolism (IEM) is also high in Oman. This retrospective cross-sectional study was designed to evaluate the number of patients with IEM being followed at the only two tertiary centers in Oman treating such patients, and to calculate the consanguinity rates among these families. The electronic medical records of all patients were reviewed for demographic and clinical characteristics. A total of 285 patients with IEM were being followed at the 2 centers involved; 162 (56.8%) were male and 123 (43.2%) were female. The history of consanguinity was documented or available for 241 patients: 229 patients (95%) were born to consanguineous parents related as second cousins or closer. First-cousin marriages were reported in 191 families (79.3%), while 31 patients (12.9%) were born to second cousins. The parents of 5 patients (2%) were related as double first cousins, and 2 patients (1%) were born to first cousins once removed. The average coefficient of inbreeding (F) in our study was 0.081. Seventeen patients (6%) had associated comorbid conditions other than IEM. Our study highlights the clinical burden of IEM in Oman and emphasizes the high consanguinity rates among the parents of affected patients. © 2014 S. Karger AG, Basel
Milk Intakes Are Not Associated with Percent Body Fat in Children from Ages 10 to 13 Years12
Noel, Sabrina E.; Ness, Andrew R.; Northstone, Kate; Emmett, Pauline; Newby, P. K.
2011-01-01
Epidemiologic studies report conflicting results for the relationship between milk intake and adiposity in children. We examined prospective and cross-sectional associations between milk intake and percent body fat among 2245 children from the Avon Longitudinal Study of Parents and Children. Cross-sectional analyses were performed at age 13 y between total, full-fat, and reduced-fat milk intake assessed using 3-d dietary records and body fat from DXA. Prospective analyses were conducted between milk intakes at age 10 y and body fat at 11 and 13 y. Models were adjusted for age, sex, height, physical activity, pubertal status, maternal BMI, maternal education, and intakes of total fat, sugar-sweetened beverages, 100% fruit juice, and ready-to-eat cereals; baseline BMI was added to prospective models. Subset analyses were performed for those with plausible dietary intakes. Mean milk consumption at 10 and 13 y was (mean ± SD) 0.90 ± 0.73 and 0.85 ± 0.78 servings/d [1 serving = 8 oz of milk (244 g of plain and 250 g flavored milk)], respectively. Cross-sectional results indicated an inverse association between full-fat milk intake and body fat [β = −0.47 (95% CI = −0.76, −0.19); P = 0.001]. Milk intake at age 10 y was inversely associated with body fat at 11 y [β = −0.16 g/d (95%CI = −0.28, −0.04); P = 0.01], but not among those with plausible dietary intakes, suggesting that this association was influenced by dietary measurement errors. Milk intake was not associated with body fat at age 13 y after adjustment. Although our prospective results corroborate other findings of a null associations between milk intake and adiposity, our inconsistent findings across analyses suggest further investigation is needed to clarify the relation, and accounting for dietary reporting errors is an important consideration. PMID:21940511
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ulmer, W.
2015-06-15
Purpose: The knowledge of the total nuclear cross-section Qtot(E) of therapeutic protons Qtot(E) provides important information in advanced radiotherapy with protons, such as the decrease of fluence of primary protons, the release of secondary particles (neutrons, protons, deuterons, etc.), and the production of nuclear fragments (heavy recoils), which usually undergo β+/− decay by emission of γ-quanta. Therefore determination of Qtot(E) is an important tool for sophisticated calculation algorithms of dose distributions. This cross-section can be determined by a linear combination of shifted Gaussian kernels and an error-function. The resonances resulting from deconvolutions in the energy space can be associated withmore » typical nuclear reactions. Methods: The described method of the determination of Qtot(E) results from an extension of the Breit-Wigner formula and a rather extended version of the nuclear shell theory to include nuclear correlation effects, clusters and highly excited/virtually excited nuclear states. The elastic energy transfer of protons to nucleons (the quantum numbers of the target nucleus remain constant) can be removed by the mentioned deconvolution. Results: The deconvolution of the term related to the error-function of the type cerf*er((E-ETh)/σerf] is the main contribution to obtain various nuclear reactions as resonances, since the elastic part of energy transfer is removed. The nuclear products of various elements of therapeutic interest like oxygen, calcium are classified and calculated. Conclusions: The release of neutrons is completely underrated, in particular, for low-energy protons. The transport of seconary particles, e.g. cluster formation by deuterium, tritium and α-particles, show an essential contribution to secondary particles, and the heavy recoils, which create γ-quanta by decay reactions, lead to broadening of the scatter profiles. These contributions cannot be accounted for by one single Gaussian kernel for the description of lateral scatter.« less
Comparison of two target classification techniques
NASA Astrophysics Data System (ADS)
Chen, J. S.; Walton, E. K.
1986-01-01
Radar target classification techniques based on backscatter measurements in the resonance region (1.0-20.0 MHz) are discussed. Attention is given to two novel methods currently being tested at the radar range of Ohio State University. The methods include: (1) the nearest neighbor (NN) algorithm for determining the radar cross section (RCS) magnitude and range corrected phase at various operating frequencies; and (2) an inverse Fourier transformation of the complex multifrequency radar returns of the time domain, followed by cross correlation analysis. Comparisons are made of the performance of the two techniques as a function of signal-to-error noise ratio for different types of processing. The results of the comparison are discussed in detail.
A national physician survey of diagnostic error in paediatrics.
Perrem, Lucy M; Fanshawe, Thomas R; Sharif, Farhana; Plüddemann, Annette; O'Neill, Michael B
2016-10-01
This cross-sectional survey explored paediatric physician perspectives regarding diagnostic errors. All paediatric consultants and specialist registrars in Ireland were invited to participate in this anonymous online survey. The response rate for the study was 54 % (n = 127). Respondents had a median of 9-year clinical experience (interquartile range (IQR) 4-20 years). A diagnostic error was reported at least monthly by 19 (15.0 %) respondents. Consultants reported significantly less diagnostic errors compared to trainees (p value = 0.01). Cognitive error was the top-ranked contributing factor to diagnostic error, with incomplete history and examination considered to be the principal cognitive error. Seeking a second opinion and close follow-up of patients to ensure that the diagnosis is correct were the highest-ranked, clinician-based solutions to diagnostic error. Inadequate staffing levels and excessive workload were the most highly ranked system-related and situational factors. Increased access to and availability of consultants and experts was the most highly ranked system-based solution to diagnostic error. We found a low level of self-perceived diagnostic error in an experienced group of paediatricians, at variance with the literature and warranting further clarification. The results identify perceptions on the major cognitive, system-related and situational factors contributing to diagnostic error and also key preventative strategies. • Diagnostic errors are an important source of preventable patient harm and have an estimated incidence of 10-15 %. • They are multifactorial in origin and include cognitive, system-related and situational factors. What is New: • We identified a low rate of self-perceived diagnostic error in contrast to the existing literature. • Incomplete history and examination, inadequate staffing levels and excessive workload are cited as the principal contributing factors to diagnostic error in this study.
An approach to develop an algorithm to detect the climbing height in radial-axial ring rolling
NASA Astrophysics Data System (ADS)
Husmann, Simon; Hohmann, Magnus; Kuhlenkötter, Bernd
2017-10-01
Radial-axial ring rolling is the mainly used forming process to produce seamless rings, which are applied in miscellaneous industries like the energy sector, the aerospace technology or in the automotive industry. Due to the simultaneously forming in two opposite rolling gaps and the fact that ring rolling is a mass forming process, different errors could occur during the rolling process. Ring climbing is one of the most occurring process errors leading to a distortion of the ring's cross section and a deformation of the rings geometry. The conventional sensors of a radial-axial rolling machine could not detect this error. Therefore, it is a common strategy to roll a slightly bigger ring, so that random occurring process errors could be reduce afterwards by removing the additional material. The LPS installed an image processing system to the radial rolling gap of their ring rolling machine to enable the recognition and measurement of climbing rings and by this, to reduce the additional material. This paper presents the algorithm which enables the image processing system to detect the error of a climbing ring and ensures comparable reliable results for the measurement of the climbing height of the rings.
Shawahna, Ramzi; Al-Rjoub, Mohammed; Al-Horoub, Mohammed M; Al-Hroub, Wasif; Al-Rjoub, Bisan; Al-Nabi, Bashaaer Abd
2016-01-01
This study aimed to investigate community pharmacists' knowledge and certainty of adverse effects and contraindications of pharmaceutical products to estimate the risk of error. Factors influencing their knowledge and certainty were also investigated. The knowledge of community pharmacists was assessed in a cross-sectional design using a multiple-choice questions test on the adverse effects and contraindications of active pharmaceutical ingredients and excipients from May 2014 to March 2015. Self-rated certainty scores were also recorded for each question. Knowledge and certainty scores were combined to estimate the risk of error. Out of 315 subjects, 129 community pharmacists (41.0%) completed the 30 multiple-choice questions test on active ingredients and excipients. Knowledge on active ingredients was associated with the year of graduation and obtaining a licence to practice pharmacy. Knowledge on excipients was associated with the degree obtained. There was higher risk of error in items on excipients than those on ingredients (P<0.01). The knowledge of community pharmacists in Palestine was insufficient with high risk of errors. Knowledge of community pharmacists on the safety issues of active ingredients and excipients need to be improved.
Marais, Willem J; Holz, Robert E; Hu, Yu Hen; Kuehn, Ralph E; Eloranta, Edwin E; Willett, Rebecca M
2016-10-10
Atmospheric lidar observations provide a unique capability to directly observe the vertical column of cloud and aerosol scattering properties. Detector and solar-background noise, however, hinder the ability of lidar systems to provide reliable backscatter and extinction cross-section estimates. Standard methods for solving this inverse problem are most effective with high signal-to-noise ratio observations that are only available at low resolution in uniform scenes. This paper describes a novel method for solving the inverse problem with high-resolution, lower signal-to-noise ratio observations that are effective in non-uniform scenes. The novelty is twofold. First, the inferences of the backscatter and extinction are applied to images, whereas current lidar algorithms only use the information content of single profiles. Hence, the latent spatial and temporal information in noisy images are utilized to infer the cross-sections. Second, the noise associated with photon-counting lidar observations can be modeled using a Poisson distribution, and state-of-the-art tools for solving Poisson inverse problems are adapted to the atmospheric lidar problem. It is demonstrated through photon-counting high spectral resolution lidar (HSRL) simulations that the proposed algorithm yields inverted backscatter and extinction cross-sections (per unit volume) with smaller mean squared error values at higher spatial and temporal resolutions, compared to the standard approach. Two case studies of real experimental data are also provided where the proposed algorithm is applied on HSRL observations and the inverted backscatter and extinction cross-sections are compared against the standard approach.
Hammond, Kendra; Mampilly, Jobby; Laghi, Franco A; Goyal, Amit; Collins, Eileen G; McBurney, Conor; Jubran, Amal; Tobin, Martin J
2014-01-01
Muscle-mass loss augers increased morbidity and mortality in critically ill patients. Muscle-mass loss can be assessed by wide linear-array ultrasound transducers connected to cumbersome, expensive console units. Whether cheaper, hand-carried units equipped with curved-array transducers can be used as alternatives is unknown. Accordingly, our primary aim was to investigate in 15 nondisabled subjects the validity of measurements of rectus femoris cross-sectional area by using a curved-array transducer against a linear-array transducer-the reference-standard technique. In these subjects, we also determined the reliability of measurements obtained by a novice operator versus measurements obtained by an experienced operator. Lastly, the relationship between quadriceps strength and rectus area recorded by two experienced operators with a curved-array transducer was assessed in 17 patients with chronic obstructive pulmonary disease (COPD). In nondisabled subjects, the rectus cross-sectional area measured with the curved-array transducer by the novice and experienced operators was valid (intraclass correlation coefficient [ICC]: 0.98, typical percentage error [%TE]: 3.7%) and reliable (ICC: 0.79, %TE: 9.7%). In the subjects with COPD, both reliability (ICC: 0.99) and repeatability (%TE: 7.6% and 9.8%) were high. Rectus area was related to quadriceps strength in COPD for both experienced operators (coefficient of determination: 0.67 and 0.70). In conclusion, measurements of rectus femoris cross-sectional area recorded with a curved-array transducer connected to a hand-carried unit are valid, reliable, and reproducible, leading us to contend that this technique is suitable for cross-sectional and longitudinal studies.
Wood, Jonathan S; Donnell, Eric T; Porter, Richard J
2015-02-01
A variety of different study designs and analysis methods have been used to evaluate the performance of traffic safety countermeasures. The most common study designs and methods include observational before-after studies using the empirical Bayes method and cross-sectional studies using regression models. The propensity scores-potential outcomes framework has recently been proposed as an alternative traffic safety countermeasure evaluation method to address the challenges associated with selection biases that can be part of cross-sectional studies. Crash modification factors derived from the application of all three methods have not yet been compared. This paper compares the results of retrospective, observational evaluations of a traffic safety countermeasure using both before-after and cross-sectional study designs. The paper describes the strengths and limitations of each method, focusing primarily on how each addresses site selection bias, which is a common issue in observational safety studies. The Safety Edge paving technique, which seeks to mitigate crashes related to roadway departure events, is the countermeasure used in the present study to compare the alternative evaluation methods. The results indicated that all three methods yielded results that were consistent with each other and with previous research. The empirical Bayes results had the smallest standard errors. It is concluded that the propensity scores with potential outcomes framework is a viable alternative analysis method to the empirical Bayes before-after study. It should be considered whenever a before-after study is not possible or practical. Copyright © 2014 Elsevier Ltd. All rights reserved.
García-Rey, R M; García-Olmo, J; De Pedro, E; Quiles-Zafra, R; Luque de Castro, M D
2005-06-01
The potential of visible and near infrared spectroscopy to predict texture and colour of dry-cured ham samples was investigated. Sensory evaluation was performed on 117 boned and cross-sectioned dry-cured ham samples. Slices of approximate thickness 4cm were cut, vacuum-packaged and kept under frozen storage until spectral analysis. Then, Biceps femoris muscle from the thawed slices was taken and scanned (400-2200nm) using a fiber optic probe. The exploratory analysis using principal component analysis shows that there are two ham groups according to the appearance or not of defects. Then, a K nearest neighbours was used to classify dry-cured hams into defective or no defective classes. The overall accuracy of the classification as a function of pastiness was 88.5%; meanwhile, according to colour was 79.7%. Partial least squares regression was used to formulate prediction equations for pastiness and colour. The correlation coefficients of calibration and cross-validation were 0.97 and 0.86 for optimal equation predicting pastiness, and 0.82 and 0.69 for optimal equation predicting colour. The standard error of cross-validation for predicting pastiness and colour is between 1 and 2 times the standard deviation of the reference method (the error involved in the sensory evaluation by the experts). The magnitude of this error demonstrates the good precision of the methods for predicting pastiness and colour. Furthermore, the samples were classified into defective or no defective classes, with a correct classification of 94.2% according to pasty texture evaluation and 75.7% as regard to colour evaluation.
Benefits of regular aerobic exercise for executive functioning in healthy populations.
Guiney, Hayley; Machado, Liana
2013-02-01
Research suggests that regular aerobic exercise has the potential to improve executive functioning, even in healthy populations. The purpose of this review is to elucidate which components of executive functioning benefit from such exercise in healthy populations. In light of the developmental time course of executive functions, we consider separately children, young adults, and older adults. Data to date from studies of aging provide strong evidence of exercise-linked benefits related to task switching, selective attention, inhibition of prepotent responses, and working memory capacity; furthermore, cross-sectional fitness data suggest that working memory updating could potentially benefit as well. In young adults, working memory updating is the main executive function shown to benefit from regular exercise, but cross-sectional data further suggest that task-switching and post error performance may also benefit. In children, working memory capacity has been shown to benefit, and cross-sectional data suggest potential benefits for selective attention and inhibitory control. Although more research investigating exercise-related benefits for specific components of executive functioning is clearly needed in young adults and children, when considered across the age groups, ample evidence indicates that regular engagement in aerobic exercise can provide a simple means for healthy people to optimize a range of executive functions.
D'Atri, Valentina; Porrini, Massimiliano; Rosu, Frédéric; Gabelica, Valérie
2015-01-01
Ion mobility spectrometry experiments allow the mass spectrometrist to determine an ion's rotationally averaged collision cross section ΩEXP. Molecular modelling is used to visualize what ion three-dimensional structure(s) is(are) compatible with the experiment. The collision cross sections of candidate molecular models have to be calculated, and the resulting ΩCALC are compared with the experimental data. Researchers who want to apply this strategy to a new type of molecule face many questions: (1) What experimental error is associated with ΩEXP determination, and how to estimate it (in particular when using a calibration for traveling wave ion guides)? (2) How to generate plausible 3D models in the gas phase? (3) Different collision cross section calculation models exist, which have been developed for other analytes than mine. Which one(s) can I apply to my systems? To apply ion mobility spectrometry to nucleic acid structural characterization, we explored each of these questions using a rigid structure which we know is preserved in the gas phase: the tetramolecular G-quadruplex [dTGGGGT]4, and we will present these detailed investigation in this tutorial. © 2015 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons Ltd. PMID:26259654
Measurement and analysis of aircraft and vehicle LRCS in outfield test
NASA Astrophysics Data System (ADS)
Cao, Chang-Qing; Zeng, Xiao-dong; Fan, Zhao-jin; Feng, Zhe-jun; Lai, Zhi
2015-04-01
The measurement of aircraft and vehicle Laser Radar Cross Section (LRCS) is of crucial importance for the detection system evaluation and the characteristic research of the laser scattering. A brief introduction of the measuring theory of the laser scattering from the full-scale aircraft and vehicle targets is presented in this paper. By analyzing the measuring condition in outfield test, the laser systems and test steps are designed for full-scale aircraft and vehicle LRCS and verified by the experiment in laboratory. The processing data error 7% below is obtained of the laser radar cross section by using Gaussian compensation and elimination of sky background for original test data. The study of measurement and analysis proves that the proposed method is effective and correct to get laser radar cross section data in outfield test. The objectives of this study were: (1) to develop structural concepts for different LRCS fuselage configurations constructed of conventional materials; (2) to compare these findings with those of aircrafts or vehicles; (3) to assess the application of advanced materials for each configuration; (4) to conduct an analytical investigation of the aerodynamic loads, vertical drag and mission performance of different LRCS configurations; and (5) to compare these findings with those of the aircrafts or vehicles.
Cheng, G.
2011-07-28
The SciBooNE Collaboration reports K + production cross section and rate measurements using high energy daughter muon neutrino scattering data off the SciBar polystyrene (C 8H 8) target in the SciBooNE detector. The K + mesons are produced by 8 GeV protons striking a beryllium target in Fermilab Booster Neutrino Beam line (BNB). Using observed neutrino and antineutrino events in SciBooNE, we measure d 2σ/dpdΩ = (5.34 ±0.76) mb/(GeV/c x sr) for p + Be =K + + X at mean K + energy of 3.9 GeV and angle (with respect to the proton beam direction) of 3.7 degrees, correspondingmore » to the selected K + sample. Compared to Monte Carlo predictions using previous higher energy K + production measurements, this measurement, which uses the NUANCE neutrino interaction generator, is consistent with a normalization factor of 0.85 ± 0.12. This agreement is evidence that the extrapolation of the higher energy K + measurements to an 8 GeV beam energy using Feynman scaling is valid. This measurement reduces the error on the K + production cross section from 40% to 14%.« less
Medication Errors in Patients with Enteral Feeding Tubes in the Intensive Care Unit.
Sohrevardi, Seyed Mojtaba; Jarahzadeh, Mohammad Hossein; Mirzaei, Ehsan; Mirjalili, Mahtabalsadat; Tafti, Arefeh Dehghani; Heydari, Behrooz
2017-01-01
Most patients admitted to Intensive Care Units (ICU) have problems in using oral medication or ingesting solid forms of drugs. Selecting the most suitable dosage form in such patients is a challenge. The current study was conducted to assess the frequency and types of errors of oral medication administration in patients with enteral feeding tubes or suffering swallowing problems. A cross-sectional study was performed in the ICU of Shahid Sadoughi Hospital, Yazd, Iran. Patients were assessed for the incidence and types of medication errors occurring in the process of preparation and administration of oral medicines. Ninety-four patients were involved in this study and 10,250 administrations were observed. Totally, 4753 errors occurred among the studied patients. The most commonly used drugs were pantoprazole tablet, piracetam syrup, and losartan tablet. A total of 128 different types of drugs and nine different oral pharmaceutical preparations were prescribed for the patients. Forty-one (35.34%) out of 116 different solid drugs (except effervescent tablets and powders) could be substituted by liquid or injectable forms. The most common error was the wrong time of administration. Errors of wrong dose preparation and administration accounted for 24.04% and 25.31% of all errors, respectively. In this study, at least three-fourth of the patients experienced medication errors. The occurrence of these errors can greatly impair the quality of the patients' pharmacotherapy, and more attention should be paid to this issue.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, Ashish; /Delhi U.
2005-10-01
The measurement of the top-antitop pair production cross section in p{bar p} collisions at {radical}s = 1.96 TeV in the dielectron decay channel using 384 pb{sup -1} of D0 data yields a t{bar t} production cross-section of {sigma}{sub t{bar t}} = 7.9{sub -3.8}{sup +5.2}(stat){sub -1.0}{sup +1.3}(syst) {+-} 0.5 (lumi) pb. This measurement [98] is based on 5 observed events with a prediction of 1.04 background events. The cross-section corresponds to the top mass of 175 GeV, and is in good agreement with the Standard Model expectation of 6.77 {+-} 0.42 pb based on next-to-next-leading-order (NNLO) perturbative QCD calculations [78]. Thismore » analysis shows significant improvement from our previous cross-section measurement in this channel [93] with 230 pb{sup -1} dataset in terms of significantly better signal to background ratio and uncertainties on the measured cross-section. Combination of all the dilepton final states [98] yields a yields a t{bar t} cross-section of {sigma}{sub t{bar t}} = 8.6{sub -2.0}{sup +2.3}(stat){sub -1.0}{sup +1.2}(syst) {+-} 0.6(lumi) pb, which again is in good agreement with theoretical predictions and with measurements in other final states. Hence, these results show no discernible deviation from the Standard Model. Fig. 6.1 shows the summary of cross-section measurements in different final states by the D0 in Run II. This measurement of cross-section in the dilepton channels is the best dilepton result from D0 till date. Previous D0 result based on analysis of 230 pb{sup -1} of data (currently under publication in Physics Letters B) is {sigma}{sub t{bar t}} = 8.6{sub -2.7}{sup +3.2}(stat){sub -1.1}{sup +1.1}(syst) {+-} 0.6(lumi) pb. It can be seen that the present cross-section suffers from less statistical uncertainty. This result is also quite consistent with CDF collaboration's result of {sigma}{sub t{bar t}} = 8.6{sub -2.4}{sup +2.5}(stat){sub -1.1}{sup +1.1}(syst) pb. These results have been presented as D0's preliminary results in the high energy physics conferences in the Summer of 2005 (Hadron Collider Physics Symposium, European Physical Society Conference, etc.). The uncertainty on the cross-section is still dominated by statistics due to the small number of observed events. It can be seen that we are at a level where statistical uncertainties are becoming closer to the systematic ones. Future measurements of the cross section will benefit from considerably more integrated luminosity, leading to a smaller statistical error. Thus the next generation of measurements will be limited by systematic uncertainties. Monte Carlo samples with higher statistics are also being generated in order to decrease the uncertainty on the background estimation. In addition, as the jet energy scale, the electron energy scale, the detector resolutions, and the luminosity measurement are fine-tuned, the systematic uncertainties will continue to decrease.« less
Carnes, Debra; Kilpatrick, Sue; Iedema, Rick
2015-12-01
This study aims to determine the likelihood that rural nurses perceive a hypothetical medication error would be reported in their workplace. This employs cross-sectional survey using hypothetical error scenario with varying levels of harm. Clinical settings in rural Tasmania. Participants were 116 eligible surveys received from registered and enrolled nurses. Frequency of responses indicating the likelihood that severe, moderate and near miss (no harm) scenario would 'always' be reported or disclosed. Eighty per cent of nurses viewed a severe error would 'always' be reported, 64.8% a moderate error and 45.7% a near-miss error. In regards to disclosure, 54.7% felt this was 'always' likely to occur for a severe error, 44.8% for a moderate error and 26.4% for a near miss. Across all levels of severity, aged-care nurses were more likely than nurses in other settings to view error to 'always' be reported (ranging from 72-96%, P = 0.010 to 0.042,) and disclosed (68-88%, P = 0.000). Those in a management role were more likely to view error to 'always' be disclosed compared to those in a clinical role (50-77.3%, P = 0.008-0.024). Further research in rural clinical settings is needed to improve the understanding of error management and disclosure. © 2015 The Authors. Australian Journal of Rural Health published by Wiley Publishing Asia Pty Ltd on behalf of National Rural Health Alliance.
The intention to disclose medical errors among doctors in a referral hospital in North Malaysia.
Hs, Arvinder-Singh; Rashid, Abdul
2017-01-23
In this study, medical errors are defined as unintentional patient harm caused by a doctor's mistake. This topic, due to limited research, is poorly understood in Malaysia. The objective of this study was to determine the proportion of doctors intending to disclose medical errors, and their attitudes/perception pertaining to medical errors. This cross-sectional study was conducted at a tertiary public hospital from July- December 2015 among 276 randomly selected doctors. Data was collected using a standardized and validated self-administered questionnaire intending to measure disclosure and attitudes/perceptions. The scale had four vignettes in total two medical and two surgical. Each vignette consisted of five questions and each question measured the disclosure. Disclosure was categorised as "No Disclosure", "Partial Disclosure" or "Full Disclosure". Data was keyed in and analysed using STATA v 13.0. Only 10.1% (n = 28) intended to disclose medical errors. Most respondents felt that they possessed an attitude/perception of adequately disclosing errors to patients. There was a statistically significant difference (p < 0.001) when comparing the intention of disclosure with perceived disclosures. Most respondents were in common agreement that disclosing an error would make them less likely to get sued, that minor errors should be reported and that they experienced relief from disclosing errors. Most doctors in this study would not disclose medical errors although they perceived that the errors were serious and felt responsible for it. Poor disclosure could be due the fear of litigations and improper mechanisms/procedures available for disclosure.
Kawuma, Medi; Mayeku, Robert
2002-08-01
Refractive errors are a known cause of visual impairment and may cause blindness worldwide. In children, refractive errors may prevent those afflicted from progressing with their studies. In Uganda, like in many developing countries, there is no established vision-screening programme for children on commencement of school, such that those with early onset of such errors will have many years of poor vision. Over all, there is limited information on refractive errors among children in Africa. To determine the prevalence of refractive errors among school children attending lower primary in Kampala district; the frequency of the various types of refractive errors, and their relationship to sexuality and ethnicity. A cross-sectional descriptive study. Kampala district, Uganda A total of 623 children aged between 6 and 9 years had a visual acuity testing done at school using the same protocol; of these 301 (48.3%) were boys and 322 (51.7%) girls. Seventy-three children had a significant refractive error of +/-0.50 or worse in one or both eyes, giving a prevalence of 11.6% and the commonest single refractive error was astigmatism, which accounted for 52% of all errors. This was followed by hypermetropia, and myopia was the least common. Significant refractive errors occur among primary school children aged 6 to 9 years at a prevalence of approximately 12%. Therefore, there is a need to have regular and simple vision testing in primary school children at least at the commencement of school so as to defect those who may suffer from these disabilities.
Unit of Measurement Used and Parent Medication Dosing Errors
Dreyer, Benard P.; Ugboaja, Donna C.; Sanchez, Dayana C.; Paul, Ian M.; Moreira, Hannah A.; Rodriguez, Luis; Mendelsohn, Alan L.
2014-01-01
BACKGROUND AND OBJECTIVES: Adopting the milliliter as the preferred unit of measurement has been suggested as a strategy to improve the clarity of medication instructions; teaspoon and tablespoon units may inadvertently endorse nonstandard kitchen spoon use. We examined the association between unit used and parent medication errors and whether nonstandard instruments mediate this relationship. METHODS: Cross-sectional analysis of baseline data from a larger study of provider communication and medication errors. English- or Spanish-speaking parents (n = 287) whose children were prescribed liquid medications in 2 emergency departments were enrolled. Medication error defined as: error in knowledge of prescribed dose, error in observed dose measurement (compared to intended or prescribed dose); >20% deviation threshold for error. Multiple logistic regression performed adjusting for parent age, language, country, race/ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease; site. RESULTS: Medication errors were common: 39.4% of parents made an error in measurement of the intended dose, 41.1% made an error in the prescribed dose. Furthermore, 16.7% used a nonstandard instrument. Compared with parents who used milliliter-only, parents who used teaspoon or tablespoon units had twice the odds of making an error with the intended (42.5% vs 27.6%, P = .02; adjusted odds ratio=2.3; 95% confidence interval, 1.2–4.4) and prescribed (45.1% vs 31.4%, P = .04; adjusted odds ratio=1.9; 95% confidence interval, 1.03–3.5) dose; associations greater for parents with low health literacy and non–English speakers. Nonstandard instrument use partially mediated teaspoon and tablespoon–associated measurement errors. CONCLUSIONS: Findings support a milliliter-only standard to reduce medication errors. PMID:25022742
Unit of measurement used and parent medication dosing errors.
Yin, H Shonna; Dreyer, Benard P; Ugboaja, Donna C; Sanchez, Dayana C; Paul, Ian M; Moreira, Hannah A; Rodriguez, Luis; Mendelsohn, Alan L
2014-08-01
Adopting the milliliter as the preferred unit of measurement has been suggested as a strategy to improve the clarity of medication instructions; teaspoon and tablespoon units may inadvertently endorse nonstandard kitchen spoon use. We examined the association between unit used and parent medication errors and whether nonstandard instruments mediate this relationship. Cross-sectional analysis of baseline data from a larger study of provider communication and medication errors. English- or Spanish-speaking parents (n = 287) whose children were prescribed liquid medications in 2 emergency departments were enrolled. Medication error defined as: error in knowledge of prescribed dose, error in observed dose measurement (compared to intended or prescribed dose); >20% deviation threshold for error. Multiple logistic regression performed adjusting for parent age, language, country, race/ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease; site. Medication errors were common: 39.4% of parents made an error in measurement of the intended dose, 41.1% made an error in the prescribed dose. Furthermore, 16.7% used a nonstandard instrument. Compared with parents who used milliliter-only, parents who used teaspoon or tablespoon units had twice the odds of making an error with the intended (42.5% vs 27.6%, P = .02; adjusted odds ratio=2.3; 95% confidence interval, 1.2-4.4) and prescribed (45.1% vs 31.4%, P = .04; adjusted odds ratio=1.9; 95% confidence interval, 1.03-3.5) dose; associations greater for parents with low health literacy and non-English speakers. Nonstandard instrument use partially mediated teaspoon and tablespoon-associated measurement errors. Findings support a milliliter-only standard to reduce medication errors. Copyright © 2014 by the American Academy of Pediatrics.
Pokhai, Gabriel G; Oliver, Michele L; Gordon, Karen D
2009-09-01
Determination of the biomechanical properties of soft tissues such as tendons and ligaments is dependent on the accurate measurement of their cross-sectional area (CSA). Measurement methods, which involve contact with the specimen, are problematic because soft tissues are easily deformed. Noncontact measurement methods are preferable in this regard, but may experience difficulty in dealing with the complex cross-sectional shapes and glistening surfaces seen in soft tissues. Additionally, existing CSA measurement systems are separated from the materials testing machine, resulting in the inability to measure CSA during testing. Furthermore, CSA measurements are usually made in a different orientation, and with a different preload, prior to testing. To overcome these problems, a noncontact laser reflectance system (LRS) was developed. Designed to fit in an Instron 8872 servohydraulic test machine, the system measures CSA by orbiting a laser transducer in a circular path around a soft tissue specimen held by tissue clamps. CSA measurements can be conducted before and during tensile testing. The system was validated using machined metallic specimens of various shapes and sizes, as well as different sizes of bovine tendons. The metallic specimens could be measured to within 4% accuracy, and the tendons to within an average error of 4.3%. Statistical analyses showed no significant differences between the measurements of the LRS and those of the casting method, an established measurement technique. The LRS was successfully used to measure the changing CSA of bovine tendons during uniaxial tensile testing. The LRS developed in this work represents a simple, quick, and accurate way of reconstructing complex cross-sectional profiles and calculating cross-sectional areas. In addition, the LRS represents the first system capable of automatically measuring changing CSA of soft tissues during tensile testing, facilitating the calculation of more accurate biomechanical properties.
Zeraatchi, Alireza; Talebian, Mohammad-Taghi; Nejati, Amir; Dashti-Khavidaki, Simin
2013-07-01
Emergency departments (EDs) are characterized by simultaneous care of multiple patients with various medical conditions. Due to a large number of patients with complex diseases, speed and complexity of medication use, working in under-staffing and crowded environment, medication errors are commonly perpetrated by emergency care providers. This study was designed to evaluate the incidence of medication errors among patients attending to an ED in a teaching hospital in Iran. In this cross-sectional study, a total of 500 patients attending to ED were randomly assessed for incidence and types of medication errors. Some factors related to medication errors such as working shift, weekdays and schedule of the educational program of trainee were also evaluated. Nearly, 22% of patients experienced at least one medication error. The rate of medication errors were 0.41 errors per patient and 0.16 errors per ordered medication. The frequency of medication errors was higher in men, middle age patients, first weekdays, night-time work schedules and the first semester of educational year of new junior emergency medicine residents. More than 60% of errors were prescription errors by physicians and the remaining were transcription or administration errors by nurses. More than 35% of the prescribing errors happened during the selection of drug dose and frequency. The most common medication errors by nurses during the administration were omission error (16.2%) followed by unauthorized drug (6.4%). Most of the medication errors happened for anticoagulants and thrombolytics (41.2%) followed by antimicrobial agents (37.7%) and insulin (7.4%). In this study, at least one-fifth of the patients attending to ED experienced medication errors resulting from multiple factors. More common prescription errors happened during ordering drug dose and frequency. More common administration errors included dug omission or unauthorized drug.
Arul, Pitchaikaran; Pushparaj, Magesh; Pandian, Kanmani; Chennimalai, Lingasamy; Rajendran, Karthika; Selvaraj, Eniya; Masilamani, Suresh
2018-01-01
An important component of laboratory medicine is preanalytical phase. Since laboratory report plays a major role in patient management, more importance should be given to the quality of laboratory tests. The present study was undertaken to find the prevalence and types of preanalytical errors at a tertiary care hospital in South India. In this cross-sectional study, a total of 118,732 samples ([62,474 outpatient department [OPD] and 56,258 inpatient department [IPD]) were received in hematology laboratory. These samples were analyzed for preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples. The overall prevalence of preanalytical errors found was 513 samples, which is 0.43% of the total number of samples received. The most common preanalytical error observed was inadequate samples followed by clotted samples. Overall frequencies (both OPD and IPD) of preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples were 0.02%, 0.05%, 0.2%, 0.12%, 0.02%, and 0.03%, respectively. The present study concluded that incorrect phlebotomy techniques due to lack of awareness is the main reason for preanalytical errors. This can be avoided by proper communication and coordination between laboratory and wards, proper training and continuing medical education programs for laboratory and paramedical staffs, and knowledge of the intervening factors that can influence laboratory results.
Rectifying calibration error of Goldmann applanation tonometer is easy!
Choudhari, Nikhil S; Moorthy, Krishna P; Tungikar, Vinod B; Kumar, Mohan; George, Ronnie; Rao, Harsha L; Senthil, Sirisha; Vijaya, Lingam; Garudadri, Chandra Sekhar
2014-11-01
Purpose: Goldmann applanation tonometer (GAT) is the current Gold standard tonometer. However, its calibration error is common and can go unnoticed in clinics. Its company repair has limitations. The purpose of this report is to describe a self-taught technique of rectifying calibration error of GAT. Materials and Methods: Twenty-nine slit-lamp-mounted Haag-Streit Goldmann tonometers (Model AT 900 C/M; Haag-Streit, Switzerland) were included in this cross-sectional interventional pilot study. The technique of rectification of calibration error of the tonometer involved cleaning and lubrication of the instrument followed by alignment of weights when lubrication alone didn't suffice. We followed the South East Asia Glaucoma Interest Group's definition of calibration error tolerance (acceptable GAT calibration error within ±2, ±3 and ±4 mm Hg at the 0, 20 and 60-mm Hg testing levels, respectively). Results: Twelve out of 29 (41.3%) GATs were out of calibration. The range of positive and negative calibration error at the clinically most important 20-mm Hg testing level was 0.5 to 20 mm Hg and -0.5 to -18 mm Hg, respectively. Cleaning and lubrication alone sufficed to rectify calibration error of 11 (91.6%) faulty instruments. Only one (8.3%) faulty GAT required alignment of the counter-weight. Conclusions: Rectification of calibration error of GAT is possible in-house. Cleaning and lubrication of GAT can be carried out even by eye care professionals and may suffice to rectify calibration error in the majority of faulty instruments. Such an exercise may drastically reduce the downtime of the Gold standard tonometer.
Dehghan, Ashraf; Abumasoudi, Rouhollah Sheikh; Ehsanpour, Soheila
2016-01-01
Infertility and errors in the process of its treatment have a negative impact on infertile couples. The present study was aimed to identify and assess the common errors in the reception process by applying the approach of "failure modes and effects analysis" (FMEA). In this descriptive cross-sectional study, the admission process of fertility and infertility center of Isfahan was selected for evaluation of its errors based on the team members' decision. At first, the admission process was charted through observations and interviewing employees, holding multiple panels, and using FMEA worksheet, which has been used in many researches all over the world and also in Iran. Its validity was evaluated through content and face validity, and its reliability was evaluated through reviewing and confirmation of the obtained information by the FMEA team, and eventually possible errors, causes, and three indicators of severity of effect, probability of occurrence, and probability of detection were determined and corrective actions were proposed. Data analysis was determined by the number of risk priority (RPN) which is calculated by multiplying the severity of effect, probability of occurrence, and probability of detection. Twenty-five errors with RPN ≥ 125 was detected through the admission process, in which six cases of error had high priority in terms of severity and occurrence probability and were identified as high-risk errors. The team-oriented method of FMEA could be useful for assessment of errors and also to reduce the occurrence probability of errors.
Dehghan, Ashraf; Abumasoudi, Rouhollah Sheikh; Ehsanpour, Soheila
2016-01-01
Background: Infertility and errors in the process of its treatment have a negative impact on infertile couples. The present study was aimed to identify and assess the common errors in the reception process by applying the approach of “failure modes and effects analysis” (FMEA). Materials and Methods: In this descriptive cross-sectional study, the admission process of fertility and infertility center of Isfahan was selected for evaluation of its errors based on the team members’ decision. At first, the admission process was charted through observations and interviewing employees, holding multiple panels, and using FMEA worksheet, which has been used in many researches all over the world and also in Iran. Its validity was evaluated through content and face validity, and its reliability was evaluated through reviewing and confirmation of the obtained information by the FMEA team, and eventually possible errors, causes, and three indicators of severity of effect, probability of occurrence, and probability of detection were determined and corrective actions were proposed. Data analysis was determined by the number of risk priority (RPN) which is calculated by multiplying the severity of effect, probability of occurrence, and probability of detection. Results: Twenty-five errors with RPN ≥ 125 was detected through the admission process, in which six cases of error had high priority in terms of severity and occurrence probability and were identified as high-risk errors. Conclusions: The team-oriented method of FMEA could be useful for assessment of errors and also to reduce the occurrence probability of errors. PMID:28194208
Nurses' attitude and intention of medication administration error reporting.
Hung, Chang-Chiao; Chu, Tsui-Ping; Lee, Bih-O; Hsiao, Chia-Chi
2016-02-01
The Aims of this study were to explore the effects of nurses' attitudes and intentions regarding medication administration error reporting on actual reporting behaviours. Underreporting of medication errors is still a common occurrence. Whether attitude and intention towards medication administration error reporting connect to actual reporting behaviours remain unclear. This study used a cross-sectional design with self-administered questionnaires, and the theory of planned behaviour was used as the framework for this study. A total of 596 staff nurses who worked in general wards and intensive care units in a hospital were invited to participate in this study. The researchers used the instruments measuring nurses' attitude, nurse managers' and co-workers' attitude, report control, and nurses' intention to predict nurses' actual reporting behaviours. Data were collected from September-November 2013. Path analyses were used to examine the hypothesized model. Of the 596 nurses invited to participate, 548 (92%) completed and returned a valid questionnaire. The findings indicated that nurse managers' and co-workers' attitudes are predictors for nurses' attitudes towards medication administration error reporting. Nurses' attitudes also influenced their intention to report medication administration errors; however, no connection was found between intention and actual reporting behaviour. The findings reflected links among colleague perspectives, nurses' attitudes, and intention to report medication administration errors. The researchers suggest that hospitals should increase nurses' awareness and recognition of error occurrence. Regardless of nurse managers' and co-workers' attitudes towards medication administration error reporting, nurses are likely to report medication administration errors if they detect them. Management of medication administration errors should focus on increasing nurses' awareness and recognition of error occurrence. © 2015 John Wiley & Sons Ltd.
IAEA CIELO Evaluation of Neutron-induced Reactions on 235U and 238U Targets
Capote, R.; Trkov, A.; Sin, M.; ...
2018-02-01
Evaluations of nuclear reaction data for the major uranium isotopes 238U and 235U were performed within the scope of the CIELO Project on the initiative of the OECD/NEA Data Bank under Working Party on Evaluation Co-operation (WPEC) Subgroup 40 coordinated by the IAEA Nuclear Data Section. Both the mean values and covariances are evaluated from 10 -5 eV up to 30 MeV. The resonance parameters of 238U and 235U were re-evaluated with the addition of newly available data to the existing experimental database. The evaluations in the fast neutron range are based on nuclear model calculations with the code EMPIRE–3.2more » Malta above the resonance range up to 30 MeV. 235U(n,f), 238U(n,f), and 238U(n,γ) cross sections and 235U(n th,f) prompt fission neutron spectrum (PFNS) were evaluated within the Neutron Standards project and are representative of the experimental state-of-the-art measurements. The Standards cross sections were matched in model calculations as closely as possible to guarantee a good predictive power for cross sections of competing neutron scattering channels. 235U(n,γ) cross section includes fluctuations observed in recent experiments. 235U(n,f) PFNS for incident neutron energies from 500 keV to 20 MeV were measured at Los Alamos Chi-Nu facility and re-evaluated using all available experimental data. While respecting the measured differential data, several compensating errors in previous evaluations were identified and removed so that the performance in integral benchmarks was restored or improved. Covariance matrices for 235U and 238U cross sections, angular distributions, spectra and neutron multiplicities were evaluated using the GANDR system that combines experimental data with model uncertainties. Unrecognized systematic uncertainties were considered in the uncertainty quantification for fission and capture cross sections above the thermal range, and for neutron multiplicities. Evaluated files were extensively benchmarked to ensure good performance in reactor calculations and fusion-related systems. New comprehensive evaluations show excellent agreement with available differential data and integral performance better than current evaluated data libraries, and represent a step forward in a quest for better nuclear data for applications.« less
IAEA CIELO Evaluation of Neutron-induced Reactions on 235U and 238U Targets
NASA Astrophysics Data System (ADS)
Capote, R.; Trkov, A.; Sin, M.; Pigni, M. T.; Pronyaev, V. G.; Balibrea, J.; Bernard, D.; Cano-Ott, D.; Danon, Y.; Daskalakis, A.; Goričanec, T.; Herman, M. W.; Kiedrowski, B.; Kopecky, S.; Mendoza, E.; Neudecker, D.; Leal, L.; Noguere, G.; Schillebeeckx, P.; Sirakov, I.; Soukhovitskii, E. S.; Stetcu, I.; Talou, P.
2018-02-01
Evaluations of nuclear reaction data for the major uranium isotopes 238U and 235U were performed within the scope of the CIELO Project on the initiative of the OECD/NEA Data Bank under Working Party on Evaluation Co-operation (WPEC) Subgroup 40 coordinated by the IAEA Nuclear Data Section. Both the mean values and covariances are evaluated from 10-5 eV up to 30 MeV. The resonance parameters of 238U and 235U were re-evaluated with the addition of newly available data to the existing experimental database. The evaluations in the fast neutron range are based on nuclear model calculations with the code EMPIRE-3.2 Malta above the resonance range up to 30 MeV. 235U(n,f), 238U(n,f), and 238U(n,γ) cross sections and 235U(nth,f) prompt fission neutron spectrum (PFNS) were evaluated within the Neutron Standards project and are representative of the experimental state-of-the-art measurements. The Standards cross sections were matched in model calculations as closely as possible to guarantee a good predictive power for cross sections of competing neutron scattering channels. 235U(n,γ) cross section includes fluctuations observed in recent experiments. 235U(n,f) PFNS for incident neutron energies from 500 keV to 20 MeV were measured at Los Alamos Chi-Nu facility and re-evaluated using all available experimental data. While respecting the measured differential data, several compensating errors in previous evaluations were identified and removed so that the performance in integral benchmarks was restored or improved. Covariance matrices for 235U and 238U cross sections, angular distributions, spectra and neutron multiplicities were evaluated using the GANDR system that combines experimental data with model uncertainties. Unrecognized systematic uncertainties were considered in the uncertainty quantification for fission and capture cross sections above the thermal range, and for neutron multiplicities. Evaluated files were extensively benchmarked to ensure good performance in reactor calculations and fusion-related systems. New comprehensive evaluations show excellent agreement with available differential data and integral performance better than current evaluated data libraries, and represent a step forward in a quest for better nuclear data for applications.
IAEA CIELO Evaluation of Neutron-induced Reactions on 235U and 238U Targets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Capote, R.; Trkov, A.; Sin, M.
Evaluations of nuclear reaction data for the major uranium isotopes 238U and 235U were performed within the scope of the CIELO Project on the initiative of the OECD/NEA Data Bank under Working Party on Evaluation Co-operation (WPEC) Subgroup 40 coordinated by the IAEA Nuclear Data Section. Both the mean values and covariances are evaluated from 10 -5 eV up to 30 MeV. The resonance parameters of 238U and 235U were re-evaluated with the addition of newly available data to the existing experimental database. The evaluations in the fast neutron range are based on nuclear model calculations with the code EMPIRE–3.2more » Malta above the resonance range up to 30 MeV. 235U(n,f), 238U(n,f), and 238U(n,γ) cross sections and 235U(n th,f) prompt fission neutron spectrum (PFNS) were evaluated within the Neutron Standards project and are representative of the experimental state-of-the-art measurements. The Standards cross sections were matched in model calculations as closely as possible to guarantee a good predictive power for cross sections of competing neutron scattering channels. 235U(n,γ) cross section includes fluctuations observed in recent experiments. 235U(n,f) PFNS for incident neutron energies from 500 keV to 20 MeV were measured at Los Alamos Chi-Nu facility and re-evaluated using all available experimental data. While respecting the measured differential data, several compensating errors in previous evaluations were identified and removed so that the performance in integral benchmarks was restored or improved. Covariance matrices for 235U and 238U cross sections, angular distributions, spectra and neutron multiplicities were evaluated using the GANDR system that combines experimental data with model uncertainties. Unrecognized systematic uncertainties were considered in the uncertainty quantification for fission and capture cross sections above the thermal range, and for neutron multiplicities. Evaluated files were extensively benchmarked to ensure good performance in reactor calculations and fusion-related systems. New comprehensive evaluations show excellent agreement with available differential data and integral performance better than current evaluated data libraries, and represent a step forward in a quest for better nuclear data for applications.« less
Small Scale Mass Flow Plug Calibration
NASA Technical Reports Server (NTRS)
Sasson, Jonathan
2015-01-01
A simple control volume model has been developed to calculate the discharge coefficient through a mass flow plug (MFP) and validated with a calibration experiment. The maximum error of the model in the operating region of the MFP is 0.54%. The model uses the MFP geometry and operating pressure and temperature to couple continuity, momentum, energy, an equation of state, and wall shear. Effects of boundary layer growth and the reduction in cross-sectional flow area are calculated using an in- integral method. A CFD calibration is shown to be of lower accuracy with a maximum error of 1.35%, and slower by a factor of 100. Effects of total pressure distortion are taken into account in the experiment. Distortion creates a loss in flow rate and can be characterized by two different distortion descriptors.
Jang, Cheongjae; Ha, Junhyoung; Dupont, Pierre E.; Park, Frank Chongwoo
2017-01-01
Although existing mechanics-based models of concentric tube robots have been experimentally demonstrated to approximate the actual kinematics, determining accurate estimates of model parameters remains difficult due to the complex relationship between the parameters and available measurements. Further, because the mechanics-based models neglect some phenomena like friction, nonlinear elasticity, and cross section deformation, it is also not clear if model error is due to model simplification or to parameter estimation errors. The parameters of the superelastic materials used in these robots can be slowly time-varying, necessitating periodic re-estimation. This paper proposes a method for estimating the mechanics-based model parameters using an extended Kalman filter as a step toward on-line parameter estimation. Our methodology is validated through both simulation and experiments. PMID:28717554
Effect of bird maneuver on frequency-domain helicopter EM response
Fitterman, D.V.; Yin, C.
2004-01-01
Bird maneuver, the rotation of the coil-carrying instrument pod used for frequency-domain helicopter electromagnetic surveys, changes the nominal geometric relationship between the bird-coil system and the ground. These changes affect electromagnetic coupling and can introduce errors in helicopter electromagnetic, (HEM) data. We analyze these effects for a layered half-space for three coil configurations: vertical coaxial, vertical coplanar, and horizontal coplanar. Maneuver effect is shown to have two components: one that is purely geometric and another that is inductive in nature. The geometric component is significantly larger. A correction procedure is developed using an iterative approach that uses standard HEM inversion routines. The maneuver effect correction reduces inversion misfit error and produces laterally smoother cross sections than obtained from uncorrected data. ?? 2004 Society of Exploration Geophysicists. All rights reserved.
Estimating Dense Cardiac 3D Motion Using Sparse 2D Tagged MRI Cross-sections*
Ardekani, Siamak; Gunter, Geoffrey; Jain, Saurabh; Weiss, Robert G.; Miller, Michael I.; Younes, Laurent
2015-01-01
In this work, we describe a new method, an extension of the Large Deformation Diffeomorphic Metric Mapping to estimate three-dimensional deformation of tagged Magnetic Resonance Imaging Data. Our approach relies on performing non-rigid registration of tag planes that were constructed from set of initial reference short axis tag grids to a set of deformed tag curves. We validated our algorithm using in-vivo tagged images of normal mice. The mapping allows us to compute root mean square distance error between simulated tag curves in a set of long axis image planes and the acquired tag curves in the same plane. Average RMS error was 0.31±0.36(SD) mm, which is approximately 2.5 voxels, indicating good matching accuracy. PMID:25571140
Prediction Accuracy of Error Rates for MPTB Space Experiment
NASA Technical Reports Server (NTRS)
Buchner, S. P.; Campbell, A. B.; Davis, D.; McMorrow, D.; Petersen, E. L.; Stassinopoulos, E. G.; Ritter, J. C.
1998-01-01
This paper addresses the accuracy of radiation-induced upset-rate predictions in space using the results of ground-based measurements together with standard environmental and device models. The study is focused on two part types - 16 Mb NEC DRAM's (UPD4216) and 1 Kb SRAM's (AMD93L422) - both of which are currently in space on board the Microelectronics and Photonics Test Bed (MPTB). To date, ground-based measurements of proton-induced single event upset (SEM cross sections as a function of energy have been obtained and combined with models of the proton environment to predict proton-induced error rates in space. The role played by uncertainties in the environmental models will be determined by comparing the modeled radiation environment with the actual environment measured aboard MPTB. Heavy-ion induced upsets have also been obtained from MPTB and will be compared with the "predicted" error rate following ground testing that will be done in the near future. These results should help identify sources of uncertainty in predictions of SEU rates in space.
Olson, Stephen M; Hussaini, Mohammad; Lewis, James S
2011-05-01
Frozen section analysis is an essential tool for assessing margins intra-operatively to assure complete resection. Many institutions evaluate surgical defect edge tissue provided by the surgeon after the main lesion has been removed. With the increasing use of transoral laser microsurgery, this method is becoming even more prevalent. We sought to evaluate error rates at our large academic institution and to see if sampling errors could be reduced by the simple method change of taking an additional third section on these specimens. All head and neck tumor resection cases from January 2005 through August 2008 with margins evaluated by frozen section were identified by database search. These cases were analyzed by cutting two levels during frozen section and a third permanent section later. All resection cases from August 2008 through July 2009 were identified as well. These were analyzed by cutting three levels during frozen section (the third a 'much deeper' level) and a fourth permanent section later. Error rates for both of these periods were determined. Errors were separated into sampling and interpretation types. There were 4976 total frozen section specimens from 848 patients. The overall error rate was 2.4% for all frozen sections where just two levels were evaluated and was 2.5% when three levels were evaluated (P=0.67). The sampling error rate was 1.6% for two-level sectioning and 1.2% for three-level sectioning (P=0.42). However, when considering only the frozen section cases where tumor was ultimately identified (either at the time of frozen section or on permanent sections) the sampling error rate for two-level sectioning was 15.3 versus 7.4% for three-level sectioning. This difference was statistically significant (P=0.006). Cutting a single additional 'deeper' level at the time of frozen section identifies more tumor-bearing specimens and may reduce the number of sampling errors.
Transportation and Centering Ability of Neoniti and ProTaper Instruments; A CBCT Assessment
Madani, Zahrasadat; Soleymani, Ali; Bagheri, Tasnim; Moudi, Ehsan; Bijani, Ali; Rakhshan, Vahid
2017-01-01
Introduction: Transportation is an important iatrogenic endodontic error which might cause failure. This study evaluated the canal transportation caused by Neoniti and ProTaper instruments, using cone-beam computed tomography (CBCT) cross sections. Methods and Materials: This in vitro experimental study was performed on 40 mesiobuccal roots of maxillary first molars. The teeth were scanned with CBCT. They were randomly divided into 2 groups (n=20) that were prepared using either Neoniti or ProTaper files. An endodontist prepared the canal according to the manufacturer’s guidelines. Prepared canals were re-scanned. The pre-instrumentation and post-instrumentation CBCT volumes were sectioned at 1 to 9-mm distances from the apex. The extent of canal dentine removal in mesial and distal directions were measured in each cross-section. Canal transportation and instrument centering ability were estimated based on the extents of root wall removal and were compared in both groups. Results: The groups were rather similar in terms of transportation and centering ability (P>0.05). However, canal preparation on mesial and distal walls was statistically significantly less in the Neoniti group, at most cross-sections. Transportation of both groups was not significantly different (P>0.05). Centering ability of both instruments was not significantly different (P>0.05). Conclusion: Neoniti and ProTaper instruments might have proper centering ability and minimum transportations. Both instruments might cause similar extents of transportation and centering abilities. PMID:28179923
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldsmith, John
High Spectral Resolution Lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are absolutely calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar but unlike simple backscatter lidars such as the micropulse lidar, the HSRL can measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations also allow robust discrimination between ice and water clouds. In addition, rigorous error estimates can be computed for all measurements. A very narrow, angularmore » field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. There are two operational U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility HSRL systems, one at the Barrow North Slope of Alaska (NSA) site and the other in the second ARM Mobile Facility (AMF2) collection of instrumentation.« less
Illiquidity premium and expected stock returns in the UK: A new approach
NASA Astrophysics Data System (ADS)
Chen, Jiaqi; Sherif, Mohamed
2016-09-01
This study examines the relative importance of liquidity risk for the time-series and cross-section of stock returns in the UK. We propose a simple way to capture the multidimensionality of illiquidity. Our analysis indicates that existing illiquidity measures have considerable asset specific components, which justifies our new approach. Further, we use an alternative test of the Amihud (2002) measure and parametric and non-parametric methods to investigate whether liquidity risk is priced in the UK. We find that the inclusion of the illiquidity factor in the capital asset pricing model plays a significant role in explaining the cross-sectional variation in stock returns, in particular with the Fama-French three-factor model. Further, using Hansen-Jagannathan non-parametric bounds, we find that the illiquidity-augmented capital asset pricing models yield a small distance error, other non-liquidity based models fail to yield economically plausible distance values. Our findings have important implications for managing the liquidity risk of equity portfolios.
NASA Astrophysics Data System (ADS)
Sharma, Gaurav; Puri, Nitin K.; Kumar, Pravin; Nandi, T.
2018-03-01
The versatility of X-ray absorption technique is experimentally employed for enhancing the detector resolution and to rejuvenate the low probable transitions obscured in the pile-up region, during a beam-foil spectroscopy experiment. The multiple aluminum absorber layers (10 μm each) are used to suppress the pile-up contribution drastically and to restore a weak transition which is about 1.38 × 104 times weaker than a one-electron-one-photon transitions viz. Kα and Khα. The weak line is possibly originating from a two-electron-one-photon transition in He-like Ti. Further, the transitions, which were obscured in the spectra due to high intensity ratio, are revived by dissimilar line intensity attenuation using this technique. The measured lifetimes of Kα line with and without intensity attenuation match well within error bar. The present technique finds potential implications in understanding the structure of multiple-core-vacant ions and other low cross section processes in ion-solid collisions.
NASA Technical Reports Server (NTRS)
Bhatia, A. K.; Temkin, A.; Fisher, Richard R. (Technical Monitor)
2001-01-01
We report on the first part of a study of electron-hydrogen scattering, using a method which allows for the ab initio calculation of total and elastic cross sections at higher energies. In its general form the method uses complex 'radial' correlation functions, in a (Kohn) T-matrix formalism. The titled method, abbreviated Complex Correlation Kohn T (CCKT) method, is reviewed, in the context of electron-hydrogen scattering, including the derivation of the equation for the (complex) scattering function, and the extraction of the scattering information from the latter. The calculation reported here is restricted to S-waves in the elastic region, where the correlation functions can be taken, without loss of generality, to be real. Phase shifts are calculated using Hylleraas-type correlation functions with up to 95 terms. Results are rigorous lower bounds; they are in general agreement with those of Schwartz, but they are more accurate and outside his error bounds at a couple of energies,
Bang, W; Barbui, M; Bonasera, A; Quevedo, H J; Dyer, G; Bernstein, A C; Hagel, K; Schmidt, K; Gaul, E; Donovan, M E; Consoli, F; De Angelis, R; Andreoli, P; Barbarino, M; Kimura, S; Mazzocco, M; Natowitz, J B; Ditmire, T
2013-09-01
We report on experiments in which the Texas Petawatt laser irradiated a mixture of deuterium or deuterated methane clusters and helium-3 gas, generating three types of nuclear fusion reactions: D(d,^{3}He)n, D(d,t)p, and ^{3}He(d,p)^{4}He. We measured the yields of fusion neutrons and protons from these reactions and found them to agree with yields based on a simple cylindrical plasma model using known cross sections and measured plasma parameters. Within our measurement errors, the fusion products were isotropically distributed. Plasma temperatures, important for the cross sections, were determined by two independent methods: (1) deuterium ion time of flight and (2) utilizing the ratio of neutron yield to proton yield from D(d,^{3}He)n and ^{3}He(d,p)^{4}He reactions, respectively. This experiment produced the highest ion temperature ever achieved with laser-irradiated deuterium clusters.
Measurement of the natHf(d,x)177Ta cross section and impact of erroneous gamma-ray intensities
NASA Astrophysics Data System (ADS)
Simonelli, F.; Abbas, K.; Bulgheroni, A.; Pommé, S.; Altzitzoglou, T.; Suliman, G.
2012-08-01
In this work, excitation functions for deuteron-induced reactions on natural hafnium have been measured in the energy range 7-17 MeV, using the stacked-foil technique. Particular attention has been paid to the reaction natHf(d,x)177Ta, because reported γ-ray intensities have been found to be in disagreement with previously published data. This discrepancy is due to an error in the 2003 ENSDF absolute γ-ray intensities of 177Hf following the decay of 177Ta, which are about a factor of three higher compared to other available data. As a consquence, some peer reviewed papers reporting on natHf(d,x)177Ta, and also on natHf(p,x) 177Ta and natW(p,x) 177Ta, need to be reviewed. An upcoming re-evaluation of the 177Ta decay data shows new significant changes in the absolute γ-ray intensities, which in turn will affect again the 177Ta producing cross sections.
Probing the top-quark width using the charge identification of b jets
Giardino, Pier Paolo; Zhang, Cen
2017-07-18
We propose a new method for measuring the top-quark width based on the on-/off-shell ratio of b -charge asymmetry in pp → Wbj production at the LHC. The charge asymmetry removes virtually all backgrounds and related uncertainties, while remaining systematic and theoretical uncertainties can be taken under control by the ratio of cross sections. Limited only by statistical error, in an optimistic scenario, we find that our approach leads to good precision at high integrated luminosity, at a few hundred MeV assuming 300 – 3000 fb -1 at the LHC. The approach directly probes the total width, in such amore » way that model-dependence can be minimized. It is complementary to existing cross section measurements which always leave a degeneracy between the total rate and the branching ratio, and provides valuable information about the properties of the top quark. Here, the proposal opens up new opportunities for precision top measurements using a b-charge identification algorithm.« less
THM and primordial nucleosynthesis: Results and perspectives
NASA Astrophysics Data System (ADS)
Pizzone, R. G.; Spartá, R.; Bertulani, C.; Spitaleri, C.; La Cognata, M.; Lamia, L.; Tumino, A.
2017-09-01
Big Bang Nucleosynthesis (BBN) requires several nuclear physics inputs and nuclear reaction rates. An up-to-date compilation of direct cross sections of d(d,p)t, d(d,n) 3 He and 3 He(d,p) 4 He reactions is given, being these ones among the most uncertain bare-nucleus cross sections. An intense experimental effort has been carried on in the last decade to apply the Trojan Horse Method (THM) to study reactions of relevance for the BBN and measure their astrophysical S( E) -factor. The reaction rates and the relative error for the four reactions of interest are then numerically calculated in the temperature ranges of relevance for BBN ( 0.01
Jeon, Hong Jin; Kim, Ji-Hae; Kim, Bin-Na; Park, Seung Jin; Fava, Maurizio; Mischoulon, David; Kang, Eun-Ho; Roh, Sungwon; Lee, Dongsoo
2014-12-01
Human error is defined as an unintended error that is attributable to humans rather than machines, and that is important to avoid to prevent accidents. We aimed to investigate the association between sleep quality and human errors among train drivers. Cross-sectional. Population-based. A sample of 5,480 subjects who were actively working as train drivers were recruited in South Korea. The participants were 4,634 drivers who completed all questionnaires (response rate 84.6%). None. The Pittsburgh Sleep Quality Index (PSQI), the Center for Epidemiologic Studies Depression Scale (CES-D), the Impact of Event Scale-Revised (IES-R), the State-Trait Anxiety Inventory (STAI), and the Korean Occupational Stress Scale (KOSS). Of 4,634 train drivers, 349 (7.5%) showed more than one human error per 5 y. Human errors were associated with poor sleep quality, higher PSQI total scores, short sleep duration at night, and longer sleep latency. Among train drivers with poor sleep quality, those who experienced severe posttraumatic stress showed a significantly higher number of human errors than those without. Multiple logistic regression analysis showed that human errors were significantly associated with poor sleep quality and posttraumatic stress, whereas there were no significant associations with depression, trait and state anxiety, and work stress after adjusting for age, sex, education years, marital status, and career duration. Poor sleep quality was found to be associated with more human errors in train drivers, especially in those who experienced severe posttraumatic stress. © 2014 Associated Professional Sleep Societies, LLC.
The impact of work-related stress on medication errors in Eastern Region Saudi Arabia.
Salam, Abdul; Segal, David M; Abu-Helalah, Munir Ahmad; Gutierrez, Mary Lou; Joosub, Imran; Ahmed, Wasim; Bibi, Rubina; Clarke, Elizabeth; Qarni, Ali Ahmed Al
2018-05-07
To examine the relationship between overall level and source-specific work-related stressors on medication errors rate. A cross-sectional study examined the relationship between overall levels of stress, 25 source-specific work-related stressors and medication error rate based on documented incident reports in Saudi Arabia (SA) hospital, using secondary databases. King Abdulaziz Hospital in Al-Ahsa, Eastern Region, SA. Two hundred and sixty-nine healthcare professionals (HCPs). The odds ratio (OR) and corresponding 95% confidence interval (CI) for HCPs documented incident report medication errors and self-reported sources of Job Stress Survey. Multiple logistic regression analysis identified source-specific work-related stress as significantly associated with HCPs who made at least one medication error per month (P < 0.05), including disruption to home life, pressure to meet deadlines, difficulties with colleagues, excessive workload, income over 10 000 riyals and compulsory night/weekend call duties either some or all of the time. Although not statistically significant, HCPs who reported overall stress were two times more likely to make at least one medication error per month than non-stressed HCPs (OR: 1.95, P = 0.081). This is the first study to use documented incident reports for medication errors rather than self-report to evaluate the level of stress-related medication errors in SA HCPs. Job demands, such as social stressors (home life disruption, difficulties with colleagues), time pressures, structural determinants (compulsory night/weekend call duties) and higher income, were significantly associated with medication errors whereas overall stress revealed a 2-fold higher trend.
[Validation of a method for notifying and monitoring medication errors in pediatrics].
Guerrero-Aznar, M D; Jiménez-Mesa, E; Cotrina-Luque, J; Villalba-Moreno, A; Cumplido-Corbacho, R; Fernández-Fernández, L
2014-12-01
To analyze the impact of a multidisciplinary and decentralized safety committee in the pediatric management unit, and the joint implementation of a computing network application for reporting medication errors, monitoring the follow-up of the errors, and an analysis of the improvements introduced. An observational, descriptive, cross-sectional, pre-post intervention study was performed. An analysis was made of medication errors reported to the central safety committee in the twelve months prior to introduction, and those reported to the decentralized safety committee in the management unit in the nine months after implementation, using the computer application, and the strategies generated by the analysis of reported errors. Number of reported errors/10,000 days of stay, number of reported errors with harm per 10,000 days of stay, types of error, categories based on severity, stage of the process, and groups involved in the notification of medication errors. Reported medication errors increased 4.6 -fold, from 7.6 notifications of medication errors per 10,000 days of stay in the pre-intervention period to 36 in the post-intervention, rate ratio 0.21 (95% CI; 0.11-0.39) (P<.001). The medication errors with harm or requiring monitoring reported per 10,000 days of stay, was virtually unchanged from one period to the other ratio rate 0,77 (95% IC; 0,31-1,91) (P>.05). The notification of potential errors or errors without harm per 10,000 days of stay increased 17.4-fold (rate ratio 0.005., 95% CI; 0.001-0.026, P<.001). The increase in medication errors notified in the post-intervention period is a reflection of an increase in the motivation of health professionals to report errors through this new method. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Pajunen, Tuuli; Saranto, Kaija; Lehtonen, Lasse
2016-01-01
Background The rapid expansion in the use of electronic health records (EHR) has increased the number of medical errors originating in health information systems (HIS). The sociotechnical approach helps in understanding risks in the development, implementation, and use of EHR and health information technology (HIT) while accounting for complex interactions of technology within the health care system. Objective This study addresses two important questions: (1) “which of the common EHR error types are associated with perceived high- and extreme-risk severity ratings among EHR users?”, and (2) “which variables are associated with high- and extreme-risk severity ratings?” Methods This study was a quantitative, non-experimental, descriptive study of EHR users. We conducted a cross-sectional web-based questionnaire study at the largest hospital district in Finland. Statistical tests included the reliability of the summative scales tested with Cronbach’s alpha. Logistic regression served to assess the association of the independent variables to each of the eight risk factors examined. Results A total of 2864 eligible respondents provided the final data. Almost half of the respondents reported a high level of risk related to the error type “extended EHR unavailability”. The lowest overall risk level was associated with “selecting incorrectly from a list of items”. In multivariate analyses, profession and clinical unit proved to be the strongest predictors for high perceived risk. Physicians perceived risk levels to be the highest (P<.001 in six of eight error types), while emergency departments, operating rooms, and procedure units were associated with higher perceived risk levels (P<.001 in four of eight error types). Previous participation in eLearning courses on EHR-use was associated with lower risk for some of the risk factors. Conclusions Based on a large number of Finnish EHR users in hospitals, this study indicates that HIT safety hazards should be taken very seriously, particularly in operating rooms, procedure units, emergency departments, and intensive care units/critical care units. Health care organizations should use proactive and systematic assessments of EHR risks before harmful events occur. An EHR training program should be compulsory for all EHR users in order to address EHR safety concerns resulting from the failure to use HIT appropriately. PMID:27154599
MRI of bone marrow in the distal radius: in vivo precision of effective transverse relaxation times
NASA Technical Reports Server (NTRS)
Grampp, S.; Majumdar, S.; Jergas, M.; Lang, P.; Gies, A.; Genant, H. K.
1995-01-01
The effective transverse relaxation time T2* is influenced by the presence of trabecular bone, and can potentially provide a measure of bone density as well as bone structure. We determined the in vivo precision of T2* in repeated bone marrow measurements. The T2* measurements of the bone marrow of the distal radius were performed twice within 2 weeks in six healthy young volunteers using a modified water-presaturated 3D Gradient-Recalled Acquisition at Steady State (GRASS) sequence with TE 7, 10, 12, 20, and 30; TR 67; flip angle (FA) 90 degrees. An axial volume covering a length of 5.6 cm in the distal radius was measured. Regions of interest (ROIs) were determined manually and consisted of the entire trabecular bone cross-section extending proximally from the radial subchondral endplate. Reproducibility of T2* and area measurements was expressed as the absolute precision error (standard deviation [SD] in ms or mm2) or as the relative precision error (SD/mean x 100, or coefficient of variation [CV] in %) between the two-point measurements. Short-term precision of T2* and area measurements varied depending on section thickness and location of the ROI in the distal radius. Absolute precision errors for T2* times were between 1.3 and 2.9 ms (relative precision errors 3.8-9.5 %) and for area measurements between 20 and 55 mm2 (relative precision errors 5.1-16.4%). This MR technique for quantitative assessment of trabecular bone density showed reasonable reproducibility in vivo and is a promising future tool for the assessment of osteoporosis.
Modeling and analysis of caves using voxelization
NASA Astrophysics Data System (ADS)
Szeifert, Gábor; Szabó, Tivadar; Székely, Balázs
2014-05-01
Although there are many ways to create three dimensional representations of caves using modern information technology methods, modeling of caves has been challenging for researchers for a long time. One of these promising new alternative modeling methods is using voxels. We are using geodetic measurements as an input for our voxelization project. These geodetic underground surveys recorded the azimuth, altitude and distance of corner points of cave systems relative to each other. The diameter of each cave section is estimated from separate databases originating from different surveys. We have developed a simple but efficient method (it covers more than 99.9 % of the volume of the input model on the average) to convert these vector-type datasets to voxels. We have also developed software components to make visualization of the voxel and vector models easier. Since each cornerpoint position is measured relative to another cornerpoints positions, propagation of uncertainties is an important issue in case of long caves with many separate sections. We are using Monte Carlo simulations to analyze the effect of the error of each geodetic instrument possibly involved in a survey. Cross-sections of the simulated three dimensional distributions show, that even tiny uncertainties of individual measurements can result in high variation of positions that could be reduced by distributing the closing errors if such data are available. Using the results of our simulations, we can estimate cave volume and the error of the calculated cave volume depending on the complexity of the cave. Acknowledgements: the authors are grateful to Ariadne Karst and Cave Exploring Association and State Department of Environmental and Nature Protection of the Hungarian Ministry of Rural Development, Department of National Parks and Landscape Protection, Section Landscape and Cave Protection and Ecotourism for providing the cave measurement data. BS contributed as an Alexander von Humboldt Research Fellow.
Veenhuis, Jack E.
2002-01-01
The upper middle Rio Grande Basin, as defined by the U.S. Army Corps of Engineers, extends from the headwaters of the Rio Grande in southwestern Colorado to Fort Quitman, Texas. Most of the basin has a semiarid climate typical of the southwestern United States. This climate drives a highly variable streamflow regime that contributes to the complexity of water management in the basin. Currently, rapid population growth in the basin has resulted in increasing demands on the hydrologic system. Water management decisions have become increasingly complex because of the broad range of interests and issues. For these reasons, the U.S. Geological Survey, in cooperation with the City of Albuquerque, New Mexico, conducted paired flow measurements at two cross sections to determine cross-sectional loss in the Albuquerque reach of the Rio Grande. This report statistically summarizes flow losses in the Albuquerque reach of the Rio Grande during the winter nonirrigation season from December 1996 to February 2000. The two previous flow-loss investigations are statistically summarized. Daily mean flow losses are calculated for the winter nonirrigation season using daily mean flows at three selected Rio Grande streamflow-gaging stations.For the winter nonirrigation season cross-sectional measurements (1996-2000), an average of 210 cubic feet per second was returned to the river between the measurement sites, of which 165 cubic feet per second was intercepted by riverside drains along the 21.9-mile reach from the Rio Grande near Bernalillo to the Rio Grande at Rio Bravo Bridge streamflow-gaging stations. Total cross-sectional losses in this reach averaged about 90 cubic feet per second. Regression equations were determined for estimating downstream total outflow from upstream total inflow for all three paired measurement studies. Regression equations relating the three daily mean flow recording stations also were determined. In each succeeding study, additional outside variables were controlled, which provided more accurate flow-loss measurements. Regression-equation losses between measurement cross sections ranged from 1.9 to 7.9 percent during the nonirrigation season and from about 5.9 to 6.4 percent during the irrigation season. Mean and median loss by reach length for all three daily mean flow stations and all three cross-sectional measurement reaches showed consistent flow loss per mile by season with allowance for nonideal river conditions for the initial measurement studies. Unsteady measurement conditions were reflected in the regression equation mean-square errors and ultimately in the change in daily mean discharge at the Rio Grande at Albuquerque gaging station during the measurement periods.
Association Between Hay Fever and High Myopia in United States Adolescents and Adults.
Shafer, Brian M; Qiu, Mary; Rapuano, Christopher J; Shields, Carol L
2017-05-01
To investigate the relationship between hay fever and refractive error in a representative sample of adolescents and adults in the United States. This cross-sectional study included 5,744 participants aged ≥12 years from the 2005 to 2006 National Health and Nutrition Examination Survey who participated in the allergy questionnaire, completed objective refraction and keratometry in both eyes, and had immunoglobulin E (IgE) serology. The primary predictor variable, refractive error, was classified as emmetropia (-0.99 to +0.99 diopters [D]), low myopia (-1.00 to -2.99 D), moderate myopia (-3.00 to -5.99 D), high myopia (≥-6.00 D), or hyperopia (≥1.00 D). Covariates included age, gender, race, asthma, eczema, total serum IgE ≥120 kU/L, corneal steepness, and corneal astigmatism. The primary outcome was hay fever. The study population's mean age was 41.7 years; 48.8% of subjects were men and 51.2% were women. The prevalence of hay fever was 12.1% overall. High myopes had 2.7 times higher odds of hay fever compared to emmetropes (OR 2.67, CI, 1.57-4.51, P=0.001), which was independent of demographics, atopic conditions, IgE serology, and keratometry measurements. The association between hay fever and high myopia identified in this large cross-sectional study remains speculative and was not mediated through corneal steepness or corneal astigmatism. Further prospective studies may help elucidate the directionality of the association between hay fever and high myopia.
Prevalence of refractive errors among school children in gondar town, northwest ethiopia.
Yared, Assefa Wolde; Belaynew, Wasie Taye; Destaye, Shiferaw; Ayanaw, Tsegaw; Zelalem, Eshete
2012-10-01
Many children with poor vision due to refractive error remain undiagnosed and perform poorly in school. The situation is worse in the Sub-Saharan Africa, including Ethiopia, and current information is lacking. The objective of this study is to determine the prevalence of refractive error among children enrolled in elementary schools in Gondar town, Ethiopia. This was a cross-sectional study of 1852 students in 8 elementary schools. Subjects were selected by multistage random sampling. The study parameters were visual acuity (VA) evaluation and ocular examination. VA was measured by staff optometrists with the Snellen E-chart while students with subnormal vision were examined using pinhole, retinoscopy evaluation and subjective refraction by ophthalmologists. The study cohort was comprised of 45.8% males and 54.2% females from 8 randomly selected elementary schools with a response rate of 93%. Refractive errors in either eye were present in 174 (9.4%) children. Of these, myopia was diagnosed in 55 (31.6%) children in the right and left eyes followed by hyperopia in 46 (26.4%) and 39 (22.4%) in the right and left eyes respectively. Low myopia was the most common refractive error in 61 (49.2%) and 68 (50%) children for the right and left eyes respectively. Refractive error among children is a common problem in Gondar town and needs to be assessed at every health evaluation of school children for timely treatment.
Patient safety awareness among Undergraduate Medical Students in Pakistani Medical School
Kamran, Rizwana; Bari, Attia; Khan, Rehan Ahmed; Al-Eraky, Mohamed
2018-01-01
Objective: To measure the level of awareness of patient safety among undergraduate medical students in Pakistani Medical School and to find the difference with respect to gender and prior experience with medical error. Methods: This cross-sectional study was conducted at the University of Lahore (UOL), Pakistan from January to March 2017, and comprised final year medical students. Data was collected using a questionnaire ‘APSQ- III’ on 7 point Likert scale. Eight questions were reverse coded. Survey was anonymous. SPSS package 20 was used for statistical analysis. Results: Questionnaire was filled by 122 students, with 81% response rate. The best score 6.17 was given for the ‘team functioning’, followed by 6.04 for ‘long working hours as a cause of medical error’. The domains regarding involvement of patient, confidence to report medical errors and role of training and learning on patient safety scored high in the agreed range of >5. Reverse coded questions about ‘professional incompetence as an error cause’ and ‘disclosure of errors’ showed negative perception. No significant differences of perceptions were found with respect to gender and prior experience with medical error (p= >0.05). Conclusion: Undergraduate medical students at UOL had a positive attitude towards patient safety. However, there were misconceptions about causes of medical errors and error disclosure among students and patient safety education needs to be incorporated in medical curriculum of Pakistan. PMID:29805398
Medical Errors and Barriers to Reporting in Ten Hospitals in Southern Iran
Khammarnia, Mohammad; Ravangard, Ramin; Barfar, Eshagh; Setoodehzadeh, Fatemeh
2015-01-01
Background: International research shows that medical errors (MEs) are a major threat to patient safety. The present study aimed to describe MEs and barriers to reporting them in Shiraz public hospitals, Iran. Methods: A cross-sectional, retrospective study was conducted in 10 Shiraz public hospitals in the south of Iran, 2013. Using the standardised checklist of Shiraz University of Medical Sciences (referred to the Clinical Governance Department and recorded documentations) and Uribe questionnaire, we gathered the data in the hospitals. Results: A total of 4379 MEs were recorded in 10 hospitals. The highest frequency (27.1%) was related to systematic errors. Besides, most of the errors had occurred in the largest hospital (54.9%), internal wards (36.3%), and morning shifts (55.0%). The results revealed a significant association between the MEs and wards and hospitals (p < 0.001). Moreover, individual and organisational factors were the barriers to reporting ME in the studied hospitals. Also, a significant correlation was observed between the ME reporting barriers and the participants’ job experiences (p < 0.001). Conclusion: The medical errors were highly frequent in the studied hospitals especially in the larger hospitals, morning shift and in the nursing practice. Moreover, individual and organisational factors were considered as the barriers to reporting MEs. PMID:28729811
Geographically correlated orbit error
NASA Technical Reports Server (NTRS)
Rosborough, G. W.
1989-01-01
The dominant error source in estimating the orbital position of a satellite from ground based tracking data is the modeling of the Earth's gravity field. The resulting orbit error due to gravity field model errors are predominantly long wavelength in nature. This results in an orbit error signature that is strongly correlated over distances on the size of ocean basins. Anderle and Hoskin (1977) have shown that the orbit error along a given ground track also is correlated to some degree with the orbit error along adjacent ground tracks. This cross track correlation is verified here and is found to be significant out to nearly 1000 kilometers in the case of TOPEX/POSEIDON when using the GEM-T1 gravity model. Finally, it was determined that even the orbit error at points where ascending and descending ground traces cross is somewhat correlated. The implication of these various correlations is that the orbit error due to gravity error is geographically correlated. Such correlations have direct implications when using altimetry to recover oceanographic signals.
Bifftu, Berhanu Boru; Dachew, Berihun Assefa; Tiruneh, Bewket Tadesse; Beshah, Debrework Tesgera
2016-01-01
Medication administration is the final step/phase of medication process in which its error directly affects the patient health. Due to the central role of nurses in medication administration, whether they are the source of an error, a contributor, or an observer they have the professional, legal and ethical responsibility to recognize and report. The aim of this study was to assess the prevalence of medication administration error reporting and associated factors among nurses working at The University of Gondar Referral Hospital, Northwest Ethiopia. Institution based quantitative cross - sectional study was conducted among 282 Nurses. Data were collected using semi-structured, self-administered questionnaire of the Medication Administration Errors Reporting (MAERs). Binary logistic regression with 95 % confidence interval was used to identify factors associated with medication administration errors reporting. The estimated medication administration error reporting was found to be 29.1 %. The perceived rates of medication administration errors reporting for non-intravenous related medications were ranged from 16.8 to 28.6 % and for intravenous-related from 20.6 to 33.4 %. Education status (AOR =1.38, 95 % CI: 4.009, 11.128), disagreement over time - error definition (AOR = 0.44, 95 % CI: 0.468, 0.990), administrative reason (AOR = 0.35, 95 % CI: 0.168, 0.710) and fear (AOR = 0.39, 95 % CI: 0.257, 0.838) were factors statistically significant for the refusal of reporting medication administration errors at p-value <0.05. In this study, less than one third of the study participants reported medication administration errors. Educational status, disagreement over time - error definition, administrative reason and fear were factors statistically significant for the refusal of errors reporting at p-value <0.05. Therefore, the results of this study suggest strategies that enhance the cultures of error reporting such as providing a clear definition of reportable errors and strengthen the educational status of nurses by the health care organization.
Geometrical accuracy improvement in flexible roll forming lines
NASA Astrophysics Data System (ADS)
Larrañaga, J.; Berner, S.; Galdos, L.; Groche, P.
2011-01-01
The general interest to produce profiles with variable cross section in a cost-effective way has increased in the last few years. The flexible roll forming process allows producing profiles with variable cross section lengthwise in a continuous way. Until now, only a few flexible roll forming lines were developed and built up. Apart from the flange wrinkling along the transition zone of u-profiles with variable cross section, the process limits have not been investigated and solutions for shape deviations are unknown. During the PROFOM project a flexible roll forming machine has been developed with the objective of producing high technological components for automotive body structures. In order to investigate the limits of the process, different profile geometries and steel grades including high strength steels have been applied. During the first experimental tests, several errors have been identified, as a result of the complex stress states generated during the forming process. In order to improve the accuracy of the target profiles and to meet the tolerance demands of the automotive industry, a thermo-mechanical solution has been proposed. Additional mechanical devices, supporting flexible the roll forming process, have been implemented in the roll forming line together with local heating techniques. The combination of both methods shows a significant increase of the accuracy. In the present investigation, the experimental results of the validation process are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, W.
2012-07-01
Recent assessment results indicate that the coarse-mesh finite-difference method (FDM) gives consistently smaller percent differences in channel powers than the fine-mesh FDM when compared to the reference MCNP solution for CANDU-type reactors. However, there is an impression that the fine-mesh FDM should always give more accurate results than the coarse-mesh FDM in theory. To answer the question if the better performance of the coarse-mesh FDM for CANDU-type reactors was just a coincidence (cancellation of errors) or caused by the use of heavy water or the use of lattice-homogenized cross sections for the cluster fuel geometry in the diffusion calculation, threemore » benchmark problems were set up with three different fuel lattices: CANDU, HWR and PWR. These benchmark problems were then used to analyze the root cause of the better performance of the coarse-mesh FDM for CANDU-type reactors. The analyses confirm that the better performance of the coarse-mesh FDM for CANDU-type reactors is mainly caused by the use of lattice-homogenized cross sections for the sub-meshes of the cluster fuel geometry in the diffusion calculation. Based on the analyses, it is recommended to use 2 x 2 coarse-mesh FDM to analyze CANDU-type reactors when lattice-homogenized cross sections are used in the core analysis. (authors)« less
DeMaris, Alfred
2014-01-01
Unmeasured confounding is the principal threat to unbiased estimation of treatment “effects” (i.e., regression parameters for binary regressors) in nonexperimental research. It refers to unmeasured characteristics of individuals that lead them both to be in a particular “treatment” category and to register higher or lower values than others on a response variable. In this article, I introduce readers to 2 econometric techniques designed to control the problem, with a particular emphasis on the Heckman selection model (HSM). Both techniques can be used with only cross-sectional data. Using a Monte Carlo experiment, I compare the performance of instrumental-variable regression (IVR) and HSM to that of ordinary least squares (OLS) under conditions with treatment and unmeasured confounding both present and absent. I find HSM generally to outperform IVR with respect to mean-square-error of treatment estimates, as well as power for detecting either a treatment effect or unobserved confounding. However, both HSM and IVR require a large sample to be fully effective. The use of HSM and IVR in tandem with OLS to untangle unobserved confounding bias in cross-sectional data is further demonstrated with an empirical application. Using data from the 2006–2010 General Social Survey (National Opinion Research Center, 2014), I examine the association between being married and subjective well-being. PMID:25110904
Trojan Horse cross section measurements and their impact on primordial nucleosynthesis
NASA Astrophysics Data System (ADS)
Pizzone, R. G.; Spartá, R.; Bertulani, C.; Spitaleri, C.; La Cognata, M.; Lamia, L.; Mukhamedzhanov, A.; Tumino, A.
2018-01-01
Big Bang Nucleosynthesis (BBN) nucleosynthesis requires several nuclear physics inputs and, among them, an important role is played by nuclear reaction rates. They are among the most important input for a quantitative description of the early Universe. An up-to-date compilation of direct cross sections of d(d,p)t, d(d,n)3He and 3He(d,p)4He reactions is given, being these ones among the most uncertain bare-nucleus cross sections. An intense experimental effort has been carried on in the last decade to apply the Trojan Horse Method (THM) to study reactions of relevance for the BBN and measure their astrophysical S(E)-factor. The result of these recent measurements is reviewed and compared with the available direct data. The reaction rates and the relative error for the four reactions of interest are then numerically calculated in the temperature ranges of relevance for BBN (0.01
Ma, Jian; Casey, Cameron P.; Zheng, Xueyun; Ibrahim, Yehia M.; Wilkins, Christopher S.; Renslow, Ryan S.; Thomas, Dennis G.; Payne, Samuel H.; Monroe, Matthew E.; Smith, Richard D.; Teeguarden, Justin G.; Baker, Erin S.; Metz, Thomas O.
2017-01-01
Abstract Motivation: Drift tube ion mobility spectrometry coupled with mass spectrometry (DTIMS-MS) is increasingly implemented in high throughput omics workflows, and new informatics approaches are necessary for processing the associated data. To automatically extract arrival times for molecules measured by DTIMS at multiple electric fields and compute their associated collisional cross sections (CCS), we created the PNNL Ion Mobility Cross Section Extractor (PIXiE). The primary application presented for this algorithm is the extraction of data that can then be used to create a reference library of experimental CCS values for use in high throughput omics analyses. Results: We demonstrate the utility of this approach by automatically extracting arrival times and calculating the associated CCSs for a set of endogenous metabolites and xenobiotics. The PIXiE-generated CCS values were within error of those calculated using commercially available instrument vendor software. Availability and implementation: PIXiE is an open-source tool, freely available on Github. The documentation, source code of the software, and a GUI can be found at https://github.com/PNNL-Comp-Mass-Spec/PIXiE and the source code of the backend workflow library used by PIXiE can be found at https://github.com/PNNL-Comp-Mass-Spec/IMS-Informed-Library. Contact: erin.baker@pnnl.gov or thomas.metz@pnnl.gov Supplementary information: Supplementary data are available at Bioinformatics online. PMID:28505286
Ma, Jian; Casey, Cameron P; Zheng, Xueyun; Ibrahim, Yehia M; Wilkins, Christopher S; Renslow, Ryan S; Thomas, Dennis G; Payne, Samuel H; Monroe, Matthew E; Smith, Richard D; Teeguarden, Justin G; Baker, Erin S; Metz, Thomas O
2017-09-01
Drift tube ion mobility spectrometry coupled with mass spectrometry (DTIMS-MS) is increasingly implemented in high throughput omics workflows, and new informatics approaches are necessary for processing the associated data. To automatically extract arrival times for molecules measured by DTIMS at multiple electric fields and compute their associated collisional cross sections (CCS), we created the PNNL Ion Mobility Cross Section Extractor (PIXiE). The primary application presented for this algorithm is the extraction of data that can then be used to create a reference library of experimental CCS values for use in high throughput omics analyses. We demonstrate the utility of this approach by automatically extracting arrival times and calculating the associated CCSs for a set of endogenous metabolites and xenobiotics. The PIXiE-generated CCS values were within error of those calculated using commercially available instrument vendor software. PIXiE is an open-source tool, freely available on Github. The documentation, source code of the software, and a GUI can be found at https://github.com/PNNL-Comp-Mass-Spec/PIXiE and the source code of the backend workflow library used by PIXiE can be found at https://github.com/PNNL-Comp-Mass-Spec/IMS-Informed-Library . erin.baker@pnnl.gov or thomas.metz@pnnl.gov. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.
Ferguson, Christopher J; Garza, Adolfo; Jerabeck, Jessica; Ramos, Raul; Galindo, Mariza
2013-01-01
The United States Supreme Court's recent decision relating to violent video games revealed divisions within the scientific community about the potential for negative effects of such games as well as the need for more, higher quality research. Scholars also have debated the potential for violent games to have positive effects such as on visuospatial cognition or math ability. The current study sought to extend previous literature by using well-validated clinical outcome measures for relevant constructs, which have generally been lacking in past research. Cross-section data on aggression, visuospatial cognition, and math achievement were available for a sample of 333 (51.7 % female) mostly Hispanic youth (mean age = 12.76). Prospective 1-year data on aggression and school GPA were available for 143 (46.2 % female) of those youth. Results from both sets of analysis revealed that exposure to violent game had neither short-term nor long-term predictive influences on either positive or negative outcomes. A developmental analysis of the cross-sectional data revealed that results did not differ across age categories of older children, preadolescents or adolescents. Analysis of effect sizes largely ruled out Type II error as a possible explanation for null results. Suggestions for new directions in the field of video game research are proffered.
Experimental Errors in QSAR Modeling Sets: What We Can Do and What We Cannot Do.
Zhao, Linlin; Wang, Wenyi; Sedykh, Alexander; Zhu, Hao
2017-06-30
Numerous chemical data sets have become available for quantitative structure-activity relationship (QSAR) modeling studies. However, the quality of different data sources may be different based on the nature of experimental protocols. Therefore, potential experimental errors in the modeling sets may lead to the development of poor QSAR models and further affect the predictions of new compounds. In this study, we explored the relationship between the ratio of questionable data in the modeling sets, which was obtained by simulating experimental errors, and the QSAR modeling performance. To this end, we used eight data sets (four continuous endpoints and four categorical endpoints) that have been extensively curated both in-house and by our collaborators to create over 1800 various QSAR models. Each data set was duplicated to create several new modeling sets with different ratios of simulated experimental errors (i.e., randomizing the activities of part of the compounds) in the modeling process. A fivefold cross-validation process was used to evaluate the modeling performance, which deteriorates when the ratio of experimental errors increases. All of the resulting models were also used to predict external sets of new compounds, which were excluded at the beginning of the modeling process. The modeling results showed that the compounds with relatively large prediction errors in cross-validation processes are likely to be those with simulated experimental errors. However, after removing a certain number of compounds with large prediction errors in the cross-validation process, the external predictions of new compounds did not show improvement. Our conclusion is that the QSAR predictions, especially consensus predictions, can identify compounds with potential experimental errors. But removing those compounds by the cross-validation procedure is not a reasonable means to improve model predictivity due to overfitting.
Experimental Errors in QSAR Modeling Sets: What We Can Do and What We Cannot Do
2017-01-01
Numerous chemical data sets have become available for quantitative structure–activity relationship (QSAR) modeling studies. However, the quality of different data sources may be different based on the nature of experimental protocols. Therefore, potential experimental errors in the modeling sets may lead to the development of poor QSAR models and further affect the predictions of new compounds. In this study, we explored the relationship between the ratio of questionable data in the modeling sets, which was obtained by simulating experimental errors, and the QSAR modeling performance. To this end, we used eight data sets (four continuous endpoints and four categorical endpoints) that have been extensively curated both in-house and by our collaborators to create over 1800 various QSAR models. Each data set was duplicated to create several new modeling sets with different ratios of simulated experimental errors (i.e., randomizing the activities of part of the compounds) in the modeling process. A fivefold cross-validation process was used to evaluate the modeling performance, which deteriorates when the ratio of experimental errors increases. All of the resulting models were also used to predict external sets of new compounds, which were excluded at the beginning of the modeling process. The modeling results showed that the compounds with relatively large prediction errors in cross-validation processes are likely to be those with simulated experimental errors. However, after removing a certain number of compounds with large prediction errors in the cross-validation process, the external predictions of new compounds did not show improvement. Our conclusion is that the QSAR predictions, especially consensus predictions, can identify compounds with potential experimental errors. But removing those compounds by the cross-validation procedure is not a reasonable means to improve model predictivity due to overfitting. PMID:28691113
Kedir, Jafer; Girma, Abonesh
2014-10-01
Refractive error is one of the major causes of blindness and visual impairment in children; but community based studies are scarce especially in rural parts of Ethiopia. So, this study aims to assess the prevalence of refractive error and its magnitude as a cause of visual impairment among school-age children of rural community. This community-based cross-sectional descriptive study was conducted from March 1 to April 30, 2009 in rural villages of Goro district of Gurage Zone, found south west of Addis Ababa, the capital of Ethiopia. A multistage cluster sampling method was used with simple random selection of representative villages in the district. Chi-Square and t-tests were used in the data analysis. A total of 570 school-age children (age 7-15) were evaluated, 54% boys and 46% girls. The prevalence of refractive error was 3.5% (myopia 2.6% and hyperopia 0.9%). Refractive error was the major cause of visual impairment accounting for 54% of all causes in the study group. No child was found wearing corrective spectacles during the study period. Refractive error was the commonest cause of visual impairment in children of the district, but no measures were taken to reduce the burden in the community. So, large scale community level screening for refractive error should be conducted and integrated with regular school eye screening programs. Effective strategies need to be devised to provide low cost corrective spectacles in the rural community.
Undergraduate paramedic students cannot do drug calculations.
Eastwood, Kathryn; Boyle, Malcolm J; Williams, Brett
2012-01-01
Previous investigation of drug calculation skills of qualified paramedics has highlighted poor mathematical ability with no published studies having been undertaken on undergraduate paramedics. There are three major error classifications. Conceptual errors involve an inability to formulate an equation from information given, arithmetical errors involve an inability to operate a given equation, and finally computation errors are simple errors of addition, subtraction, division and multiplication. The objective of this study was to determine if undergraduate paramedics at a large Australia university could accurately perform common drug calculations and basic mathematical equations normally required in the workplace. A cross-sectional study methodology using a paper-based questionnaire was administered to undergraduate paramedic students to collect demographical data, student attitudes regarding their drug calculation performance, and answers to a series of basic mathematical and drug calculation questions. Ethics approval was granted. The mean score of correct answers was 39.5% with one student scoring 100%, 3.3% of students (n=3) scoring greater than 90%, and 63% (n=58) scoring 50% or less, despite 62% (n=57) of the students stating they 'did not have any drug calculations issues'. On average those who completed a minimum of year 12 Specialist Maths achieved scores over 50%. Conceptual errors made up 48.5%, arithmetical 31.1% and computational 17.4%. This study suggests undergraduate paramedics have deficiencies in performing accurate calculations, with conceptual errors indicating a fundamental lack of mathematical understanding. The results suggest an unacceptable level of mathematical competence to practice safely in the unpredictable prehospital environment.
The relationships among work stress, strain and self-reported errors in UK community pharmacy.
Johnson, S J; O'Connor, E M; Jacobs, S; Hassell, K; Ashcroft, D M
2014-01-01
Changes in the UK community pharmacy profession including new contractual frameworks, expansion of services, and increasing levels of workload have prompted concerns about rising levels of workplace stress and overload. This has implications for pharmacist health and well-being and the occurrence of errors that pose a risk to patient safety. Despite these concerns being voiced in the profession, few studies have explored work stress in the community pharmacy context. To investigate work-related stress among UK community pharmacists and to explore its relationships with pharmacists' psychological and physical well-being, and the occurrence of self-reported dispensing errors and detection of prescribing errors. A cross-sectional postal survey of a random sample of practicing community pharmacists (n = 903) used ASSET (A Shortened Stress Evaluation Tool) and questions relating to self-reported involvement in errors. Stress data were compared to general working population norms, and regressed on well-being and self-reported errors. Analysis of the data revealed that pharmacists reported significantly higher levels of workplace stressors than the general working population, with concerns about work-life balance, the nature of the job, and work relationships being the most influential on health and well-being. Despite this, pharmacists were not found to report worse health than the general working population. Self-reported error involvement was linked to both high dispensing volume and being troubled by perceived overload (dispensing errors), and resources and communication (detection of prescribing errors). This study contributes to the literature by benchmarking community pharmacists' health and well-being, and investigating sources of stress using a quantitative approach. A further important contribution to the literature is the identification of a quantitative link between high workload and self-reported dispensing errors. Copyright © 2014 Elsevier Inc. All rights reserved.
Patterson, Mark E; Pace, Heather A; Fincham, Jack E
2013-09-01
Although error-reporting systems enable hospitals to accurately track safety climate through the identification of adverse events, these systems may be underused within a work climate of poor communication. The objective of this analysis is to identify the extent to which perceived communication climate among hospital pharmacists impacts medical error reporting rates. This cross-sectional study used survey responses from more than 5000 pharmacists responding to the 2010 Hospital Survey on Patient Safety Culture (HSOPSC). Two composite scores were constructed for "communication openness" and "feedback and about error," respectively. Error reporting frequency was defined from the survey question, "In the past 12 months, how many event reports have you filled out and submitted?" Multivariable logistic regressions were used to estimate the likelihood of medical error reporting conditional upon communication openness or feedback levels, controlling for pharmacist years of experience, hospital geographic region, and ownership status. Pharmacists with higher communication openness scores compared with lower scores were 40% more likely to have filed or submitted a medical error report in the past 12 months (OR, 1.4; 95% CI, 1.1-1.7; P = 0.004). In contrast, pharmacists with higher communication feedback scores were not any more likely than those with lower scores to have filed or submitted a medical report in the past 12 months (OR, 1.0; 95% CI, 0.8-1.3; P = 0.97). Hospital work climates that encourage pharmacists to freely communicate about problems related to patient safety is conducive to medical error reporting. The presence of feedback infrastructures about error may not be sufficient to induce error-reporting behavior.
Robust Timing Synchronization in Aeronautical Mobile Communication Systems
NASA Technical Reports Server (NTRS)
Xiong, Fu-Qin; Pinchak, Stanley
2004-01-01
This work details a study of robust synchronization schemes suitable for satellite to mobile aeronautical applications. A new scheme, the Modified Sliding Window Synchronizer (MSWS), is devised and compared with existing schemes, including the traditional Early-Late Gate Synchronizer (ELGS), the Gardner Zero-Crossing Detector (GZCD), and the Sliding Window Synchronizer (SWS). Performance of the synchronization schemes is evaluated by a set of metrics that indicate performance in digital communications systems. The metrics are convergence time, mean square phase error (or root mean-square phase error), lowest SNR for locking, initial frequency offset performance, midstream frequency offset performance, and system complexity. The performance of the synchronizers is evaluated by means of Matlab simulation models. A simulation platform is devised to model the satellite to mobile aeronautical channel, consisting of a Quadrature Phase Shift Keying modulator, an additive white Gaussian noise channel, and a demodulator front end. Simulation results show that the MSWS provides the most robust performance at the cost of system complexity. The GZCD provides a good tradeoff between robustness and system complexity for communication systems that require high symbol rates or low overall system costs. The ELGS has a high system complexity despite its average performance. Overall, the SWS, originally designed for multi-carrier systems, performs very poorly in single-carrier communications systems. Table 5.1 in Section 5 provides a ranking of each of the synchronization schemes in terms of the metrics set forth in Section 4.1. Details of comparison are given in Section 5. Based on the results presented in Table 5, it is safe to say that the most robust synchronization scheme examined in this work is the high-sample-rate Modified Sliding Window Synchronizer. A close second is its low-sample-rate cousin. The tradeoff between complexity and lowest mean-square phase error determines the rankings of the Gardner Zero-Crossing Detector and both versions of the Early-Late Gate Synchronizer. The least robust models are the high and low-sample-rate Sliding Window Synchronizers. Consequently, the recommended replacement synchronizer for NASA's Advanced Air Transportation Technologies mobile aeronautical communications system is the high-sample-rate Modified Sliding Window Synchronizer. By incorporating this synchronizer into their system, NASA can be assured that their system will be operational in extremely adverse conditions. The quick convergence time of the MSWS should allow the use of high-level protocols. However, if NASA feels that reduced system complexity is the most important aspect of their replacement synchronizer, the Gardner Zero-Crossing Detector would be the best choice.
Bhang, Soo-Young; Cho, Soo-Churl; Kim, Jae-Won; Hong, Yun-Chul; Shin, Min-Sup; Yoo, Hee Jeong; Cho, In Hee; Kim, Yeni; Kim, Bung-Nyun
2013-10-01
Manganese (Mn) is neurotoxic at high concentrations. However, Mn is an essential element that can protect against oxidative damage; thus, extremely low levels of Mn might be harmful. Our aim was to examine whether either high or low environmental Mn exposure is related to academic and attention function development among school-aged children. This cross-sectional study included 1089 children 8-11 years of age living in five representative areas in South Korea. Blood Mn, blood lead, and urine cotinine were measured. We assessed IQ with the Wechsler Abbreviated Scale of Intelligence; attention with a computerized continuous performance test called the Attention-deficit/hyperactivity disorder (ADHD) Diagnostic System (ADS), the Korean version of the Stroop Color-Word Test, the Children's Color Trails Test (CCTT), and the ADHD Rating Scale; academic functions with the Learning Disability Evaluation Scale (LDES); and emotional and behavioral problems with the Korean version of the Child Behavior Checklist (CBCL). We further assessed the presence of ADHD using a highly structured diagnostic interview, the Diagnostic Interview Schedule for Children Version IV (DISC-IV). The median blood concentration of Mn was 14.14 µg/L. We observed a nonlinear association between the CCTT2 completion time and the CPT commission error (F=3.14, p=0.03 and F=4.05, p=0.01, respectively). We divided the data into three groups: lower (<8.154 µg/L), and upper 5th percentile (>21.453 µg/L) and middle 90th percentile to determine whether a lack or overload of Mn could cause adverse effects. After adjusting for urine cotinine, blood lead, children's IQ, and other potential confounders, the high Mn group showed lower scores in thinking (B=-0.83, p=0.006), reading (B=-0.93, p=0.004), calculations (B=-0.72, p=0.005), and LQ (B=-4.06, p=0.006) in the LDES and a higher commission error in the CPT (B=8.02, p=0.048). The low Mn group showed lower color scores in the Stroop test (B=-3.24, p=0.040). We found that excess Mn in children is associated with lower scores of thinking, reading, calculation, and LQ in the LDES and higher scores of commission error in the ADS test. In contrast, lower Mn in children is associated with lower color scores in the Stroop test. The findings of this cross-sectional study suggest that excess exposure or deficiency of Mn can cause harmful effects in children. Copyright © 2013 Elsevier Inc. All rights reserved.
Kovalskys, Irina; Fisberg, Mauro; Gómez, Georgina; Rigotti, Attilio; Cortés, Lilia Yadira; Yépez, Martha Cecilia; Pareja, Rossina G; Herrera-Cuenca, Marianella; Zimberg, Ioná Z; Tucker, Katherine L; Koletzko, Berthold; Pratt, Michael
2015-09-16
Between-country comparisons of estimated dietary intake are particularly prone to error when different food composition tables are used. The objective of this study was to describe our procedures and rationale for the selection and adaptation of available food composition to a single database to enable cross-country nutritional intake comparisons. Latin American Study of Nutrition and Health (ELANS) is a multicenter cross-sectional study of representative samples from eight Latin American countries. A standard study protocol was designed to investigate dietary intake of 9000 participants enrolled. Two 24-h recalls using the Multiple Pass Method were applied among the individuals of all countries. Data from 24-h dietary recalls were entered into the Nutrition Data System for Research (NDS-R) program after a harmonization process between countries to include local foods and appropriately adapt the NDS-R database. A food matching standardized procedure involving nutritional equivalency of local food reported by the study participants with foods available in the NDS-R database was strictly conducted by each country. Standardization of food and nutrient assessments has the potential to minimize systematic and random errors in nutrient intake estimations in the ELANS project. This study is expected to result in a unique dataset for Latin America, enabling cross-country comparisons of energy, macro- and micro-nutrient intake within this region.
Kovalskys, Irina; Fisberg, Mauro; Gómez, Georgina; Rigotti, Attilio; Cortés, Lilia Yadira; Yépez, Martha Cecilia; Pareja, Rossina G.; Herrera-Cuenca, Marianella; Zimberg, Ioná Z.; Tucker, Katherine L.; Koletzko, Berthold; Pratt, Michael
2015-01-01
Between-country comparisons of estimated dietary intake are particularly prone to error when different food composition tables are used. The objective of this study was to describe our procedures and rationale for the selection and adaptation of available food composition to a single database to enable cross-country nutritional intake comparisons. Latin American Study of Nutrition and Health (ELANS) is a multicenter cross-sectional study of representative samples from eight Latin American countries. A standard study protocol was designed to investigate dietary intake of 9000 participants enrolled. Two 24-h recalls using the Multiple Pass Method were applied among the individuals of all countries. Data from 24-h dietary recalls were entered into the Nutrition Data System for Research (NDS-R) program after a harmonization process between countries to include local foods and appropriately adapt the NDS-R database. A food matching standardized procedure involving nutritional equivalency of local food reported by the study participants with foods available in the NDS-R database was strictly conducted by each country. Standardization of food and nutrient assessments has the potential to minimize systematic and random errors in nutrient intake estimations in the ELANS project. This study is expected to result in a unique dataset for Latin America, enabling cross-country comparisons of energy, macro- and micro-nutrient intake within this region. PMID:26389952
Supporting Evidence for the Astronomically Calibrated Age of Fish Canyon Sanidine
NASA Astrophysics Data System (ADS)
Rivera, T. A.; Storey, M.; Zeeden, C.; Kuiper, K.; Hilgen, F.
2010-12-01
The relative nature of the 40Ar/39Ar radio-isotopic dating technique requires that the age and error of the monitor mineral be accurately known. The most widely accepted monitor for Cenozoic geochronology is the Fish Canyon sanidine (FCs), whose recommended published ages have varied by up to 2% over the past two decades. To reconcile the discrepancy among recommended ages, researchers have turned to the use of (i) intercalibration experiments with primary argon standards, (ii) cross-calibration with U-Pb ages, and (iii) cross-calibration with sanidine-hosted tephras present in astronomically tuned stratigraphic sections. The increasingly robust quality of the astronomical timescale, with precision better than 0.1% for the last 10 million years, suggests this method of intercalibration as the best way to proceed with addressing the true age of FCs. Recently, Kuiper, et al. (2008) determined an astronomically calibrated age of 28.201 ± 0.046 Ma (2σ), based upon the Moroccan Melilla Basin Messâdit section. Here, we provide independent verification for the Kuiper, et al. (2008) FCs age using sanidines extracted from a tephra intercalated in another Mediterranean-based astronomically tuned section. The direct tuning of this section was achieved through correlation to long (~400 kyr) and short (~100 kyr) eccentricity, followed by tuning of basic sedimentary cycles to precession and summer insolation, using the La2004(1,1) astronomical solution (Laskar, et al., 2004). We employed a Nu Instruments Noblesse multi-collector noble gas mass spectrometer for the 40Ar/39Ar experiments, analyzing single crystals of FCs relative to sanidines from the astronomically dated tephra. The use of the multi-collector instrument allowed us to obtain high precision analyses with a level of precision for fully propagated external errors for FCs near the 0.1% goal of EARTHTIME. The research leading to these results has received funding from the European Community's Seventh Framework Programme (FP7/2007-2013) under grant agreement no. 215458.
Atmospheric density determination using high-accuracy satellite GPS data
NASA Astrophysics Data System (ADS)
Tingling, R.; Miao, J.; Liu, S.
2017-12-01
Atmospheric drag is the main error source in the orbit determination and prediction of low Earth orbit (LEO) satellites, however, empirical models which are used to account for atmosphere often exhibit density errors around 15 30%. Atmospheric density determination thus become an important topic for atmospheric researchers. Based on the relation between atmospheric drag force and the decay of orbit semi-major axis, we derived atmospheric density along the trajectory of CHAMP with its Rapid Science Orbit (RSO) data. Three primary parameters are calculated, including the ratio of cross sectional area to mass, drag coefficient, and the decay of semi-major axis caused by atmospheric drag. We also analyzed the source of error and made a comparison between GPS-derived and reference density. Result on 2 Dec 2008 shows that the mean error of GPS-derived density can decrease from 29.21% to 9.20% when time span adopted on the process of computation increase from 10min to 50min. Result for the whole December indicates that when the time span meet the condition that the amplitude of the decay of semi-major axis is much greater than its standard deviation, then density precision of 10% can be achieved.
Identifying the latent failures underpinning medication administration errors: an exploratory study.
Lawton, Rebecca; Carruthers, Sam; Gardner, Peter; Wright, John; McEachan, Rosie R C
2012-08-01
The primary aim of this article was to identify the latent failures that are perceived to underpin medication errors. The study was conducted within three medical wards in a hospital in the United Kingdom. The study employed a cross-sectional qualitative design. Interviews were conducted with 12 nurses and eight managers. Interviews were transcribed and subject to thematic content analysis. A two-step inter-rater comparison tested the reliability of the themes. Ten latent failures were identified based on the analysis of the interviews. These were ward climate, local working environment, workload, human resources, team communication, routine procedures, bed management, written policies and procedures, supervision and leadership, and training. The discussion focuses on ward climate, the most prevalent theme, which is conceptualized here as interacting with failures in the nine other organizational structures and processes. This study is the first of its kind to identify the latent failures perceived to underpin medication errors in a systematic way. The findings can be used as a platform for researchers to test the impact of organization-level patient safety interventions and to design proactive error management tools and incident reporting systems in hospitals. © Health Research and Educational Trust.
Evaluation of process errors in bed load sampling using a Dune Model
Gomez, Basil; Troutman, Brent M.
1997-01-01
Reliable estimates of the streamwide bed load discharge obtained using sampling devices are dependent upon good at-a-point knowledge across the full width of the channel. Using field data and information derived from a model that describes the geometric features of a dune train in terms of a spatial process observed at a fixed point in time, we show that sampling errors decrease as the number of samples collected increases, and the number of traverses of the channel over which the samples are collected increases. It also is preferable that bed load sampling be conducted at a pace which allows a number of bed forms to pass through the sampling cross section. The situations we analyze and simulate pertain to moderate transport conditions in small rivers. In such circumstances, bed load sampling schemes typically should involve four or five traverses of a river, and the collection of 20–40 samples at a rate of five or six samples per hour. By ensuring that spatial and temporal variability in the transport process is accounted for, such a sampling design reduces both random and systematic errors and hence minimizes the total error involved in the sampling process.
NASA Astrophysics Data System (ADS)
Pérez-Ràfols, Ignasi; Font-Ribera, Andreu; Miralda-Escudé, Jordi; Blomqvist, Michael; Bird, Simeon; Busca, Nicolás; du Mas des Bourboux, Hélion; Mas-Ribas, Lluís; Noterdaeme, Pasquier; Petitjean, Patrick; Rich, James; Schneider, Donald P.
2018-01-01
We present a measurement of the damped Ly α absorber (DLA) mean bias from the cross-correlation of DLAs and the Ly α forest, updating earlier results of Font-Ribera et al. (2012) with the final Baryon Oscillations Spectroscopic Survey data release and an improved method to address continuum fitting corrections. Our cross-correlation is well fitted by linear theory with the standard ΛCDM model, with a DLA bias of bDLA = 1.99 ± 0.11; a more conservative analysis, which removes DLA in the Ly β forest and uses only the cross-correlation at r > 10 h-1 Mpc, yields bDLA = 2.00 ± 0.19. This assumes the cosmological model from Planck Collaboration (2016) and the Ly α forest bias factors of Bautista et al. (2017) and includes only statistical errors obtained from bootstrap analysis. The main systematic errors arise from possible impurities and selection effects in the DLA catalogue and from uncertainties in the determination of the Ly α forest bias factors and a correction for effects of high column density absorbers. We find no dependence of the DLA bias on column density or redshift. The measured bias value corresponds to a host halo mass ∼4 × 1011 h-1 M⊙ if all DLAs were hosted in haloes of a similar mass. In a realistic model where host haloes over a broad mass range have a DLA cross-section Σ (M_h) ∝ M_h^{α } down to Mh > Mmin = 108.5 h-1 M⊙, we find that α > 1 is required to have bDLA > 1.7, implying a steeper relation or higher value of Mmin than is generally predicted in numerical simulations of galaxy formation.
UNDERSTANDING OR NURSES' REACTIONS TO ERRORS AND USING THIS UNDERSTANDING TO IMPROVE PATIENT SAFETY.
Taifoori, Ladan; Valiee, Sina
2015-09-01
The operating room can be home to many different types of nursing errors due to the invasiveness of OR procedures. The nurses' reactions towards errors can be a key factor in patient safety. This article is based on a study, with the aim of investigating nurses' reactions toward nursing errors and the various contributing and resulting factors, conducted at Kurdistan University of Medical Sciences in Sanandaj, Iran in 2014. The goal of the study was to determine how OR nurses' reacted to nursing errors with the goal of having this information used to improve patient safety. Research was conducted as a cross-sectional descriptive study. The participants were all nurses employed in the operating rooms of the teaching hospitals of Kurdistan University of Medical Sciences, which was selected by a consensus method (170 persons). The information was gathered through questionnaires that focused on demographic information, error definition, reasons for error occurrence, and emotional reactions for error occurrence, and emotional reactions toward the errors. 153 questionnaires were completed and analyzed by SPSS software version 16.0. "Not following sterile technique" (82.4 percent) was the most reported nursing error, "tiredness" (92.8 percent) was the most reported reason for the error occurrence, "being upset at having harmed the patient" (85.6 percent) was the most reported emotional reaction after error occurrence", with "decision making for a better approach to tasks the next time" (97.7 percent) as the most common goal and "paying more attention to details" (98 percent) was the most reported planned strategy for future improved outcomes. While healthcare facilities are focused on planning for the prevention and elimination of errors it was shown that nurses can also benefit from support after error occurrence. Their reactions, and coping strategies, need guidance and, with both individual and organizational support, can be a factor in improving patient safety.
Screening for refractive error among primary school children in Bayelsa state, Nigeria
Opubiri, Ibeinmo; Pedro-Egbe, Chinyere
2013-01-01
Introduction Vision screening study in primary school children has not been done in Bayelsa State. This study aims to screen for refractive error among primary school children in Bayelsa State and use the data to plan for school Eye Health Program. Methods A cross sectional study on screening for refractive error in school children was carried out in Yenagoa Local Government Area of Bayelsa State in June 2009. A multistage sampling technique was used to select the study population (pupils aged between 5-15 years). Visual acuity (VA) for each eye, was assessed outside the classroom at a distance of 6 meters. Those with VA ≤6/9 were presented with a pinhole and the test repeated. Funduscopy was done inside a poorly lit classroom. An improvement of the VA with pinhole was considered refractive error. Data was analyzed with EPI INFO version 6. Results A total of 1,242 school children consisting of 658 females and 584 males were examined.About 97.7% of pupils had normal VA (VA of 6/6) while 56 eyes had VAs ≤ 6/9. Of these 56 eyes, the visual acuity in 49 eyes (87.5%) improved with pinhole. Twenty seven pupils had refractive error, giving a prevalence of 2.2%. Refractive error involved both eyes in 22 pupils (81.5%) and the 8-10 years age range had the highest proportion (40.7%) of cases of refractive error followed by the 9-13 year-old age range (37%). Conclusion The prevalence of refractive error was 2.2% and most eyes (97.7%) had normal vision. PMID:23646210
Schwappach, David L B; Frank, Olga; Davis, Rachel E
2013-10-01
Various authorities recommend the participation of patients in promoting patient safety, but little is known about health care professionals' (HCPs') attitudes towards patients' involvement in safety-related behaviours. To investigate how HCPs evaluate patients' behaviours and HCP responses to patient involvement in the behaviour, relative to different aspects of the patient, the involved HCP and the potential error. Cross-sectional fractional factorial survey with seven factors embedded in two error scenarios (missed hand hygiene, medication error). Each survey included two randomized vignettes that described the potential error, a patient's reaction to that error and the HCP response to the patient. Twelve hospitals in Switzerland. A total of 1141 HCPs (response rate 45%). Approval of patients' behaviour, HCP response to the patient, anticipated effects on the patient-HCP relationship, HCPs' support for being asked the question, affective response to the vignettes. Outcomes were measured on 7-point scales. Approval of patients' safety-related interventions was generally high and largely affected by patients' behaviour and correct identification of error. Anticipated effects on the patient-HCP relationship were much less positive, little correlated with approval of patients' behaviour and were mainly determined by the HCP response to intervening patients. HCPs expressed more favourable attitudes towards patients intervening about a medication error than about hand sanitation. This study provides the first insights into predictors of HCPs' attitudes towards patient engagement in safety. Future research is however required to assess the generalizability of the findings into practice before training can be designed to address critical issues. © 2012 John Wiley & Sons Ltd.
Systematic errors in transport calculations of shear viscosity using the Green-Kubo formalism
NASA Astrophysics Data System (ADS)
Rose, J. B.; Torres-Rincon, J. M.; Oliinychenko, D.; Schäfer, A.; Petersen, H.
2018-05-01
The purpose of this study is to provide a reproducible framework in the use of the Green-Kubo formalism to extract transport coefficients. More specifically, in the case of shear viscosity, we investigate the limitations and technical details of fitting the auto-correlation function to a decaying exponential. This fitting procedure is found to be applicable for systems interacting both through constant and energy-dependent cross-sections, although this is only true for sufficiently dilute systems in the latter case. We find that the optimal fit technique consists in simultaneously fixing the intercept of the correlation function and use a fitting interval constrained by the relative error on the correlation function. The formalism is then applied to the full hadron gas, for which we obtain the shear viscosity to entropy ratio.
Impact of Temporal Masking of Flip-Flop Upsets on Soft Error Rates of Sequential Circuits
NASA Astrophysics Data System (ADS)
Chen, R. M.; Mahatme, N. N.; Diggins, Z. J.; Wang, L.; Zhang, E. X.; Chen, Y. P.; Liu, Y. N.; Narasimham, B.; Witulski, A. F.; Bhuva, B. L.; Fleetwood, D. M.
2017-08-01
Reductions in single-event (SE) upset (SEU) rates for sequential circuits due to temporal masking effects are evaluated. The impacts of supply voltage, combinational-logic delay, flip-flop (FF) SEU performance, and particle linear energy transfer (LET) values are analyzed for SE cross sections of sequential circuits. Alpha particles and heavy ions with different LET values are used to characterize the circuits fabricated at the 40-nm bulk CMOS technology node. Experimental results show that increasing the delay of the logic circuit present between FFs and decreasing the supply voltage are two effective ways of reducing SE error rates for sequential circuits for particles with low LET values due to temporal masking. SEU-hardened FFs benefit less from temporal masking than conventional FFs. Circuit hardening implications for SEU-hardened and unhardened FFs are discussed.
A Survey on Multimedia-Based Cross-Layer Optimization in Visual Sensor Networks
Costa, Daniel G.; Guedes, Luiz Affonso
2011-01-01
Visual sensor networks (VSNs) comprised of battery-operated electronic devices endowed with low-resolution cameras have expanded the applicability of a series of monitoring applications. Those types of sensors are interconnected by ad hoc error-prone wireless links, imposing stringent restrictions on available bandwidth, end-to-end delay and packet error rates. In such context, multimedia coding is required for data compression and error-resilience, also ensuring energy preservation over the path(s) toward the sink and improving the end-to-end perceptual quality of the received media. Cross-layer optimization may enhance the expected efficiency of VSNs applications, disrupting the conventional information flow of the protocol layers. When the inner characteristics of the multimedia coding techniques are exploited by cross-layer protocols and architectures, higher efficiency may be obtained in visual sensor networks. This paper surveys recent research on multimedia-based cross-layer optimization, presenting the proposed strategies and mechanisms for transmission rate adjustment, congestion control, multipath selection, energy preservation and error recovery. We note that many multimedia-based cross-layer optimization solutions have been proposed in recent years, each one bringing a wealth of contributions to visual sensor networks. PMID:22163908
Bankfull discharge and channel characteristics of streams in New York State
Mulvihill, Christiane I.; Baldigo, Barry P.; Miller, Sarah J.; DeKoskie, Douglas; DuBois, Joel
2009-01-01
Equations that relate drainage area to bankfull discharge and channel characteristics (such as width, depth, and cross-sectional area) at gaged sites are needed to help define bankfull discharge and channel characteristics at ungaged sites and can be used in stream-restoration and protection projects, stream-channel classification, and channel assessments. These equations are intended to serve as a guide for streams in areas of similar hydrologic, climatic, and physiographic conditions. New York State contains eight hydrologic regions that were previously delineated on the basis of high-flow (flood) characteristics. This report seeks to increase understanding of the factors affecting bankfull discharge and channel characteristics to drainage-area size relations in New York State by providing an in-depth analysis of seven previously published regional bankfull-discharge and channel-characteristics curves.Stream-survey data and discharge records from 281 cross sections at 82 streamflow-gaging stations were used in regression analyses to relate drainage area to bankfull discharge and bankfull-channel width, depth, and cross-sectional area. The R2 and standard errors of estimate of each regional equation were compared to the R2 and standard errors of estimate for the statewide (pooled) model to determine if regionalizing data reduced model variability. It was found that regional models typically yield less variable results than those obtained using pooled statewide equations, which indicates statistically significant regional differences in bankfull-discharge and channel-characteristics relations.Statistical analysis of bankfull-discharge relations found that curves for regions 4 and 7 fell outside the 95-percent confidence interval bands of the statewide model and had intercepts that were significantly diferent (p≤0.10) from the other five hydrologic regions.Analysis of channel-characteristics relations found that the bankfull width, depth, and cross-sectional area curves for region 3 were significantly different p(≤0.05) from the other six regions.It was hypothesized that some regional variability could be reduced by creating models for streams with similar physiographic and climatic characteristics. Available data on streamflow patterns and previous regional-curve research suggested that mean annual runoff, Rosgen stream type, and water-surface slope were the variables most likely to influence regional bankfull discharge and channel characteristics to drainage-area size relations. Results showed that although all of these factors had an influence on regional relations, most stratified models have lower 2 values and higher standard errors of estimate than the regional models.The New York statewide (pooled) bankfull-discharge equation and equations for regions 4 and 7 were compared with equations for four other regions in the Northeast to evaluate region-to-region differences, and assess the ability of individual curves to produce results more accurate than those that would be obtained from one model of the northeastern United States. Results indicated that model slopes lack significant diferences, though intercepts are significantly different. Comparison of bankfull-discharge estimates using different models shows that results could vary by as much as 100 percent depending on which model was used and indicated that regionalization improved model accuracy.
A novel shape-based coding-decoding technique for an industrial visual inspection system.
Mukherjee, Anirban; Chaudhuri, Subhasis; Dutta, Pranab K; Sen, Siddhartha; Patra, Amit
2004-01-01
This paper describes a unique single camera-based dimension storage method for image-based measurement. The system has been designed and implemented in one of the integrated steel plants of India. The purpose of the system is to encode the frontal cross-sectional area of an ingot. The encoded data will be stored in a database to facilitate the future manufacturing diagnostic process. The compression efficiency and reconstruction error of the lossy encoding technique have been reported and found to be quite encouraging.
2015-01-07
algorithm [30] applied across all the samples to minimize error. Morphometric analysis was carried out on CT images using CTanalyzer v. 1.4 (Bruker...remaining of 8.1 ± 1.0% was observed for uncoated PPF. 3.2. Scaffold micro-CT evaluation 3-D reconstructions of all scaffolds showed good geometric con...scaffolds. Within the single central histological cross-section, morphometric analysis indicated that the SBM scaffolds loaded with rhBMP-2 (50 and 100 lg
Zhou, Bin; Zhang, Zhendong; Wang, Ji; Yu, Y Eric; Liu, Xiaowei Sherry; Nishiyama, Kyle K; Rubin, Mishaela R; Shane, Elizabeth; Bilezikian, John P; Guo, X Edward
2016-06-01
Trabecular plate and rod microstructure plays a dominant role in the apparent mechanical properties of trabecular bone. With high-resolution computed tomography (CT) images, digital topological analysis (DTA) including skeletonization and topological classification was applied to transform the trabecular three-dimensional (3D) network into surface and curve skeletons. Using the DTA-based topological analysis and a new reconstruction/recovery scheme, individual trabecula segmentation (ITS) was developed to segment individual trabecular plates and rods and quantify the trabecular plate- and rod-related morphological parameters. High-resolution peripheral quantitative computed tomography (HR-pQCT) is an emerging in vivo imaging technique to visualize 3D bone microstructure. Based on HR-pQCT images, ITS was applied to various HR-pQCT datasets to examine trabecular plate- and rod-related microstructure and has demonstrated great potential in cross-sectional and longitudinal clinical applications. However, the reproducibility of ITS has not been fully determined. The aim of the current study is to quantify the precision errors of ITS plate-rod microstructural parameters. In addition, we utilized three different frequently used contour techniques to separate trabecular and cortical bone and to evaluate their effect on ITS measurements. Overall, good reproducibility was found for the standard HR-pQCT parameters with precision errors for volumetric BMD and bone size between 0.2%-2.0%, and trabecular bone microstructure between 4.9%-6.7% at the radius and tibia. High reproducibility was also achieved for ITS measurements using all three different contour techniques. For example, using automatic contour technology, low precision errors were found for plate and rod trabecular number (pTb.N, rTb.N, 0.9% and 3.6%), plate and rod trabecular thickness (pTb.Th, rTb.Th, 0.6% and 1.7%), plate trabecular surface (pTb.S, 3.4%), rod trabecular length (rTb.ℓ, 0.8%), and plate-plate junction density (P-P Junc.D, 2.3%) at the tibia. The precision errors at the radius were similar to those at the tibia. In addition, precision errors were affected by the contour technique. At the tibia, precision error by the manual contour method was significantly different from automatic and standard contour methods for pTb.N, rTb.N and rTb.Th. Precision error using the manual contour method was also significantly different from the standard contour method for rod trabecular number (rTb.N), rod trabecular thickness (rTb.Th), rod-rod and plate-rod junction densities (R-R Junc.D and P-R Junc.D) at the tibia. At the radius, the precision error was similar between the three different contour methods. Image quality was also found to significantly affect the ITS reproducibility. We concluded that ITS parameters are highly reproducible, giving assurance that future cross-sectional and longitudinal clinical HR-pQCT studies are feasible in the context of limited sample sizes.
2016-01-01
Objectives To assess why articles are retracted from BioMed Central journals, whether retraction notices adhered to the Committee on Publication Ethics (COPE) guidelines, and are becoming more frequent as a proportion of published articles. Design/setting Retrospective cross-sectional analysis of 134 retractions from January 2000 to December 2015. Results 134 retraction notices were published during this timeframe. Although they account for 0.07% of all articles published (190 514 excluding supplements, corrections, retractions and commissioned content), the rate of retraction is rising. COPE guidelines on retraction were adhered to in that an explicit reason for each retraction was given. However, some notices did not document who retracted the article (eight articles, 6%) and others were unclear whether the underlying cause was honest error or misconduct (15 articles, 11%). The largest proportion of notices was issued by the authors (47 articles, 35%). The majority of retractions were due to some form of misconduct (102 articles, 76%), that is, compromised peer review (44 articles, 33%), plagiarism (22 articles, 16%) and data falsification/fabrication (10 articles, 7%). Honest error accounted for 17 retractions (13%) of which 10 articles (7%) were published in error. The median number of days from publication to retraction was 337.5 days. Conclusions The most common reason to retract was compromised peer review. However, the majority of these cases date to March 2015 and appear to be the result of a systematic attempt to manipulate peer review across several publishers. Retractions due to plagiarism account for the second largest category and may be reduced by screening manuscripts before publication although this is not guaranteed. Retractions due to problems with the data may be reduced by appropriate data sharing and deposition before publication. Adopting a checklist (linked to COPE guidelines) and templates for various classes of retraction notices would increase transparency of retraction notices in future. PMID:27881524
Team safety and innovation by learning from errors in long-term care settings.
Buljac-Samardžić, Martina; van Woerkom, Marianne; Paauwe, Jaap
2012-01-01
Team safety and team innovation are underexplored in the context of long-term care. Understanding the issues requires attention to how teams cope with error. Team managers could have an important role in developing a team's error orientation and managing team membership instabilities. The aim of this study was to examine the impact of team member stability, team coaching, and a team's error orientation on team safety and innovation. A cross-sectional survey method was employed within 2 long-term care organizations. Team members and team managers received a survey that measured safety and innovation. Team members assessed member stability, team coaching, and team error orientation (i.e., problem-solving and blaming approach). The final sample included 933 respondents from 152 teams. Stable teams and teams with managers who take on the role of coach are more likely to adopt a problem-solving approach and less likely to adopt a blaming approach toward errors. Both error orientations are related to team member ratings of safety and innovation, but only the blaming approach is (negatively) related to manager ratings of innovation. Differences between members' and managers' ratings of safety are greater in teams with relatively high scores for the blaming approach and relatively low scores for the problem-solving approach. Team coaching was found to be positively related to innovation, especially in unstable teams. Long-term care organizations that wish to enhance team safety and innovation should encourage a problem-solving approach and discourage a blaming approach. Team managers can play a crucial role in this by coaching team members to see errors as sources of learning and improvement and ensuring that individuals will not be blamed for errors.
Liquid Medication Dosing Errors in Children: Role of Provider Counseling Strategies
Yin, H. Shonna; Dreyer, Benard P.; Moreira, Hannah A.; van Schaick, Linda; Rodriguez, Luis; Boettger, Susanne; Mendelsohn, Alan L.
2014-01-01
Objective To examine the degree to which recommended provider counseling strategies, including advanced communication techniques and dosing instrument provision, are associated with reductions in parent liquid medication dosing errors. Methods Cross-sectional analysis of baseline data on provider communication and dosing instrument provision from a study of a health literacy intervention to reduce medication errors. Parents whose children (<9 years) were seen in two urban public hospital pediatric emergency departments (EDs) and were prescribed daily dose liquid medications self-reported whether they received counseling about their child’s medication, including advanced strategies (teachback, drawings/pictures, demonstration, showback) and receipt of a dosing instrument. Primary dependent variable: observed dosing error (>20% deviation from prescribed). Multivariate logistic regression analyses performed, controlling for: parent age, language, country, ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease status; site. Results Of 287 parents, 41.1% made dosing errors. Advanced counseling and instrument provision in the ED were reported by 33.1% and 19.2%, respectively; 15.0% reported both. Advanced counseling and instrument provision in the ED were associated with decreased errors (30.5 vs. 46.4%, p=0.01; 21.8 vs. 45.7%, p=0.001). In adjusted analyses, ED advanced counseling in combination with instrument provision was associated with a decreased odds of error compared to receiving neither (AOR 0.3; 95% CI 0.1–0.7); advanced counseling alone and instrument alone were not significantly associated with odds of error. Conclusion Provider use of advanced counseling strategies and dosing instrument provision may be especially effective in reducing errors when used together. PMID:24767779
A long-term follow-up evaluation of electronic health record prescribing safety
Abramson, Erika L; Malhotra, Sameer; Osorio, S Nena; Edwards, Alison; Cheriff, Adam; Cole, Curtis; Kaushal, Rainu
2013-01-01
Objective To be eligible for incentives through the Electronic Health Record (EHR) Incentive Program, many providers using older or locally developed EHRs will be transitioning to new, commercial EHRs. We previously evaluated prescribing errors made by providers in the first year following transition from a locally developed EHR with minimal prescribing clinical decision support (CDS) to a commercial EHR with robust CDS. Following system refinements, we conducted this study to assess the rates and types of errors 2 years after transition and determine the evolution of errors. Materials and methods We conducted a mixed methods cross-sectional case study of 16 physicians at an academic-affiliated ambulatory clinic from April to June 2010. We utilized standardized prescription and chart review to identify errors. Fourteen providers also participated in interviews. Results We analyzed 1905 prescriptions. The overall prescribing error rate was 3.8 per 100 prescriptions (95% CI 2.8 to 5.1). Error rates were significantly lower 2 years after transition (p<0.001 compared to pre-implementation, 12 weeks and 1 year after transition). Rates of near misses remained unchanged. Providers positively appreciated most system refinements, particularly reduced alert firing. Discussion Our study suggests that over time and with system refinements, use of a commercial EHR with advanced CDS can lead to low prescribing error rates, although more serious errors may require targeted interventions to eliminate them. Reducing alert firing frequency appears particularly important. Our results provide support for federal efforts promoting meaningful use of EHRs. Conclusions Ongoing error monitoring can allow CDS to be optimally tailored and help achieve maximal safety benefits. Clinical Trials Registration ClinicalTrials.gov, Identifier: NCT00603070. PMID:23578816
Liquid medication dosing errors in children: role of provider counseling strategies.
Yin, H Shonna; Dreyer, Benard P; Moreira, Hannah A; van Schaick, Linda; Rodriguez, Luis; Boettger, Susanne; Mendelsohn, Alan L
2014-01-01
To examine the degree to which recommended provider counseling strategies, including advanced communication techniques and dosing instrument provision, are associated with reductions in parent liquid medication dosing errors. Cross-sectional analysis of baseline data on provider communication and dosing instrument provision from a study of a health literacy intervention to reduce medication errors. Parents whose children (<9 years) were seen in 2 urban public hospital pediatric emergency departments (EDs) and were prescribed daily dose liquid medications self-reported whether they received counseling about their child's medication, including advanced strategies (teachback, drawings/pictures, demonstration, showback) and receipt of a dosing instrument. The primary dependent variable was observed dosing error (>20% deviation from prescribed). Multivariate logistic regression analyses were performed, controlling for parent age, language, country, ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease status; and site. Of 287 parents, 41.1% made dosing errors. Advanced counseling and instrument provision in the ED were reported by 33.1% and 19.2%, respectively; 15.0% reported both. Advanced counseling and instrument provision in the ED were associated with decreased errors (30.5 vs. 46.4%, P = .01; 21.8 vs. 45.7%, P = .001). In adjusted analyses, ED advanced counseling in combination with instrument provision was associated with a decreased odds of error compared to receiving neither (adjusted odds ratio 0.3; 95% confidence interval 0.1-0.7); advanced counseling alone and instrument alone were not significantly associated with odds of error. Provider use of advanced counseling strategies and dosing instrument provision may be especially effective in reducing errors when used together. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
Zhou, Wen-Jun; Zhang, Yong-Ye; Li, Hua; Wu, Yu-Fei; Xu, Ji; Lv, Sha; Li, Ge; Liu, Shi-Chun; Song, Sheng-Fang
2016-01-01
Background To determine the change in refractive error and the incidence of myopia among school-aged children in the Yongchuan District of Chongqing City, Western China. Methods A population-based cross-sectional survey was initially conducted in 2006 among 3070 children aged 6 to 15 years. A longitudinal follow-up study was then conducted 5 years later between November 2011 and March 2012. Refractive error was measured under cycloplegia with autorefraction. Age, sex, and baseline refractive error were evaluated as risk factors for progression of refractive error and incidence of myopia. Results Longitudinal data were available for 1858 children (60.5%). The cumulative mean change in refractive error was −2.21 (standard deviation [SD], 1.87) diopters (D) for the entire study population, with an annual progression of refraction in a myopic direction of −0.43 D. Myopic progression of refractive error was associated with younger age, female sex, and higher myopic or hyperopic refractive error at baseline. The cumulative incidence of myopia, defined as a spherical equivalent refractive error of −0.50 D or more, among initial emmetropes and hyperopes was 54.9% (95% confidence interval [CI], 45.2%–63.5%), with an annual incidence of 10.6% (95% CI, 8.7%–13.1%). Myopia was found more likely to happen in female and older children. Conclusions In Western China, both myopic progression and incidence of myopia were higher than those of children from most other locations in China and from the European Caucasian population. Compared with a previous study in China, there was a relative increase in annual myopia progression and annual myopia incidence, a finding which is consistent with the increasing trend on prevalence of myopia in China. PMID:26875599
Zhou, Wen-Jun; Zhang, Yong-Ye; Li, Hua; Wu, Yu-Fei; Xu, Ji; Lv, Sha; Li, Ge; Liu, Shi-Chun; Song, Sheng-Fang
2016-07-05
To determine the change in refractive error and the incidence of myopia among school-aged children in the Yongchuan District of Chongqing City, Western China. A population-based cross-sectional survey was initially conducted in 2006 among 3070 children aged 6 to 15 years. A longitudinal follow-up study was then conducted 5 years later between November 2011 and March 2012. Refractive error was measured under cycloplegia with autorefraction. Age, sex, and baseline refractive error were evaluated as risk factors for progression of refractive error and incidence of myopia. Longitudinal data were available for 1858 children (60.5%). The cumulative mean change in refractive error was -2.21 (standard deviation [SD], 1.87) diopters (D) for the entire study population, with an annual progression of refraction in a myopic direction of -0.43 D. Myopic progression of refractive error was associated with younger age, female sex, and higher myopic or hyperopic refractive error at baseline. The cumulative incidence of myopia, defined as a spherical equivalent refractive error of -0.50 D or more, among initial emmetropes and hyperopes was 54.9% (95% confidence interval [CI], 45.2%-63.5%), with an annual incidence of 10.6% (95% CI, 8.7%-13.1%). Myopia was found more likely to happen in female and older children. In Western China, both myopic progression and incidence of myopia were higher than those of children from most other locations in China and from the European Caucasian population. Compared with a previous study in China, there was a relative increase in annual myopia progression and annual myopia incidence, a finding which is consistent with the increasing trend on prevalence of myopia in China.
Jensen, Jonas; Olesen, Jacob Bjerring; Stuart, Matthias Bo; Hansen, Peter Møller; Nielsen, Michael Bachmann; Jensen, Jørgen Arendt
2016-08-01
A method for vector velocity volume flow estimation is presented, along with an investigation of its sources of error and correction of actual volume flow measurements. Volume flow errors are quantified theoretically by numerical modeling, through flow phantom measurements, and studied in vivo. This paper investigates errors from estimating volumetric flow using a commercial ultrasound scanner and the common assumptions made in the literature. The theoretical model shows, e.g. that volume flow is underestimated by 15%, when the scan plane is off-axis with the vessel center by 28% of the vessel radius. The error sources were also studied in vivo under realistic clinical conditions, and the theoretical results were applied for correcting the volume flow errors. Twenty dialysis patients with arteriovenous fistulas were scanned to obtain vector flow maps of fistulas. When fitting an ellipsis to cross-sectional scans of the fistulas, the major axis was on average 10.2mm, which is 8.6% larger than the minor axis. The ultrasound beam was on average 1.5mm from the vessel center, corresponding to 28% of the semi-major axis in an average fistula. Estimating volume flow with an elliptical, rather than circular, vessel area and correcting the ultrasound beam for being off-axis, gave a significant (p=0.008) reduction in error from 31.2% to 24.3%. The error is relative to the Ultrasound Dilution Technique, which is considered the gold standard for volume flow estimation for dialysis patients. The study shows the importance of correcting for volume flow errors, which are often made in clinical practice. Copyright © 2016 Elsevier B.V. All rights reserved.
Teerawattananon, Kanlaya; Myint, Chaw-Yin; Wongkittirux, Kwanjai; Teerawattananon, Yot; Chinkulkitnivat, Bunyong; Orprayoon, Surapong; Kusakul, Suwat; Tengtrisorn, Supaporn; Jenchitr, Watanee
2014-01-01
As part of the development of a system for the screening of refractive error in Thai children, this study describes the accuracy and feasibility of establishing a program conducted by teachers. To assess the accuracy and feasibility of screening by teachers. A cross-sectional descriptive and analytical study was conducted in 17 schools in four provinces representing four geographic regions in Thailand. A two-staged cluster sampling was employed to compare the detection rate of refractive error among eligible students between trained teachers and health professionals. Serial focus group discussions were held for teachers and parents in order to understand their attitude towards refractive error screening at schools and the potential success factors and barriers. The detection rate of refractive error screening by teachers among pre-primary school children is relatively low (21%) for mild visual impairment but higher for moderate visual impairment (44%). The detection rate for primary school children is high for both levels of visual impairment (52% for mild and 74% for moderate). The focus group discussions reveal that both teachers and parents would benefit from further education regarding refractive errors and that the vast majority of teachers are willing to conduct a school-based screening program. Refractive error screening by health professionals in pre-primary and primary school children is not currently implemented in Thailand due to resource limitations. However, evidence suggests that a refractive error screening program conducted in schools by teachers in the country is reasonable and feasible because the detection and treatment of refractive error in very young generations is important and the screening program can be implemented and conducted with relatively low costs.
West, Colin P; Dyrbye, Liselotte N; Satele, Daniel V; Sloan, Jeff A; Shanafelt, Tait D
2012-11-01
Burnout is a common problem among physicians and physicians-in-training. The Maslach Burnout Inventory (MBI) is the gold standard for burnout assessment, but the length of this well-validated 22-item instrument can limit its feasibility for survey research. To evaluate the concurrent validity of two questions relative to the full MBI for measuring the association of burnout with published outcomes. DESIGN, PARTICIPANTS, AND MAIN MEASURES: The single questions "I feel burned out from my work" and "I have become more callous toward people since I took this job," representing the emotional exhaustion and depersonalization domains of burnout, respectively, were evaluated in published studies of medical students, internal medicine residents, and practicing surgeons. We compared predictive models for the association of each question, versus the full MBI, using longitudinal data on burnout and suicidality from 2006 and 2007 for 858 medical students at five United States medical schools, cross-sectional data on burnout and serious thoughts of dropping out of medical school from 2007 for 2222 medical students at seven United States medical schools, and cross-sectional data on burnout and unprofessional attitudes and behaviors from 2009 for 2566 medical students at seven United States medical schools. We also assessed results for longitudinal data on burnout and perceived major medical errors from 2003 to 2009 for 321 Mayo Clinic Rochester internal medicine residents and cross-sectional data on burnout and both perceived major medical errors and suicidality from 2008 for 7,905 respondents to a national survey of members of the American College of Surgeons. Point estimates of effect for models based on the single-item measures were uniformly consistent with those reported for models based on the full MBI. The single-item measures of emotional exhaustion and depersonalization exhibited strong associations with each published outcome (all p ≤ 0.008). No conclusion regarding the relationship between burnout and any outcome variable was altered by the use of the single-item measures rather than the full MBI. Relative to the full MBI, single-item measures of emotional exhaustion and depersonalization exhibit strong and consistent associations with key outcomes in medical students, internal medicine residents, and practicing surgeons.
Two-year changes in refractive error and related biometric factors in an adult Chinese population.
He, Mingguang; Kong, Xiangbin; Chen, Qianyun; Zeng, Yangfa; Huang, Yuanzhou; Zhang, Jian; Morgan, Ian G; Meltzer, Mirjam E; Jin, Ling; Congdon, Nathan
2014-08-01
This article provides, to our knowledge, the first longitudinal population-based data on refractive error (RE) in Chinese persons. To study cohort effects and changes associated with aging in REs among Chinese adults. A 2-year, longitudinal population-based cohort study was conducted in southern China. Participants, identified using cluster random sampling, included residents of Yuexiu District, Guangzhou, China, aged 35 years or older who had undergone no previous eye surgery. Participants underwent noncycloplegic automated refraction and keratometry in December 2008 and December 2010; in a random 50% sample of the participants, anterior segment ocular coherence tomography measurement of lens thickness, as well as measurement of axial length and anterior chamber depth by partial coherence laser interferometry, were performed. Two-year change in spherical equivalent refraction (RE), lens thickness, axial length, and anterior chamber depth in the right eye. A total of 745 individuals underwent biometric testing in both 2008 and 2010 (2008 mean [SD] age, 52.2 [11.5] years; 53.7% women). Mean RE showed a 2-year hyperopic shift from -0.44 (2.21) to -0.31 (2.26) diopters (D) (difference, +0.13; 95% CI, 0.11 to 0.16). A consistent 2-year hyperopic shift of 0.09 to 0.22 D was observed among participants aged 35 to 64 years when stratifying by decade, suggesting that a substantial change in RE with aging may occur during this 30-year period. Cross-sectionally, RE increased only in the cohort younger than 50 years (0.11 D/y; 95% CI, 0.06 to 0.16). In the cross-sectional data, axial length decreased at -0.06 mm/y (95% CI, -0.09 to -0.04), although the 2-year change in axial length was positive and thus could not explain the cross-sectional difference. These latter results suggest a cohort effect, with greater myopia developing among younger persons. This first Chinese population-based longitudinal study of RE provides evidence for both important longitudinal aging changes and cohort effects, most notably greater myopia prevalence among younger persons.
Sources of Artefacts in Synthetic Aperture Radar Interferometry Data Sets
NASA Astrophysics Data System (ADS)
Becek, K.; Borkowski, A.
2012-07-01
In recent years, much attention has been devoted to digital elevation models (DEMs) produced using Synthetic Aperture Radar Interferometry (InSAR). This has been triggered by the relative novelty of the InSAR method and its world-famous product—the Shuttle Radar Topography Mission (SRTM) DEM. However, much less attention, if at all, has been paid to sources of artefacts in SRTM. In this work, we focus not on the missing pixels (null pixels) due to shadows or the layover effect, but rather on outliers that were undetected by the SRTM validation process. The aim of this study is to identify some of the causes of the elevation outliers in SRTM. Such knowledge may be helpful to mitigate similar problems in future InSAR DEMs, notably the ones currently being developed from data acquired by the TanDEM-X mission. We analysed many cross-sections derived from SRTM. These cross-sections were extracted over the elevation test areas, which are available from the Global Elevation Data Testing Facility (GEDTF) whose database contains about 8,500 runways with known vertical profiles. Whenever a significant discrepancy between the known runway profile and the SRTM cross-section was detected, a visual interpretation of the high-resolution satellite image was carried out to identify the objects causing the irregularities. A distance and a bearing from the outlier to the object were recorded. Moreover, we considered the SRTM look direction parameter. A comprehensive analysis of the acquired data allows us to establish that large metallic structures, such as hangars or car parking lots, are causing the outliers. Water areas or plain wet terrains may also cause an InSAR outlier. The look direction and the depression angle of the InSAR system in relation to the suspected objects influence the magnitude of the outliers. We hope that these findings will be helpful in designing the error detection routines of future InSAR or, in fact, any microwave aerial- or space-based survey. The presence of outliers in SRTM was first reported in Becek, K. (2008). Investigating error structure of shuttle radar topography mission elevation data product, Geophys. Res. Lett., 35, L15403.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pražnikar, Jure; University of Primorska,; Turk, Dušan, E-mail: dusan.turk@ijs.si
2014-12-01
The maximum-likelihood free-kick target, which calculates model error estimates from the work set and a randomly displaced model, proved superior in the accuracy and consistency of refinement of crystal structures compared with the maximum-likelihood cross-validation target, which calculates error estimates from the test set and the unperturbed model. The refinement of a molecular model is a computational procedure by which the atomic model is fitted to the diffraction data. The commonly used target in the refinement of macromolecular structures is the maximum-likelihood (ML) function, which relies on the assessment of model errors. The current ML functions rely on cross-validation. Theymore » utilize phase-error estimates that are calculated from a small fraction of diffraction data, called the test set, that are not used to fit the model. An approach has been developed that uses the work set to calculate the phase-error estimates in the ML refinement from simulating the model errors via the random displacement of atomic coordinates. It is called ML free-kick refinement as it uses the ML formulation of the target function and is based on the idea of freeing the model from the model bias imposed by the chemical energy restraints used in refinement. This approach for the calculation of error estimates is superior to the cross-validation approach: it reduces the phase error and increases the accuracy of molecular models, is more robust, provides clearer maps and may use a smaller portion of data for the test set for the calculation of R{sub free} or may leave it out completely.« less
Sodium hypochlorite with reduced surface tension does not improve in situ pulp tissue dissolution.
De-Deus, Gustavo; de Berredo Pinho, Marco André; Reis, Claudia; Fidel, Sandra; Souza, Erick; Zehnder, Matthias
2013-08-01
Sodium hypochlorite (NaOCl) solutions with added wetting agents are advertised to dissolve necrotic tissue in root canals faster than their counterparts without a lowered surface tension. This was tested in the current study, and the null hypothesis formulated was that there was no difference between a commercially available NaOCl solution with a lowered surface tension (Chlor-XTRA; Vista Dental Products, Racine, WI) and a counterpart containing the same amount of available chlorine without added wetting agents regarding the soft tissue that remains in oval-shaped canals after mechanical preparation and irrigation. Formerly vital extracted teeth (N = 44, 22 pairs) with similar anatomy were radiographically paired and chemomechanically prepared. In 1 tooth from each pair, a 5.25% NaOCl solution with reduced surface tension was used; in the other, a pure, technical-grade NaOCl solution of 5.25% was used. The percentage of remaining pulp tissue (PRPT) was histologically assessed in root cross-sections. The non-Gaussian raw data were subjected to Kruskal-Wallis and Mann-Whitney U tests to verify the respective effect of the cross-section level and solution on the PRPT. The relationship between the cross-section level and the PRPT was estimated by the Spearman correlation test. The alpha-type error was set at 5%. The cross-section level significantly influenced the PRPT (P < .05), whereas the PRPT was not influenced by the solution used (P > .05). A significant inverse correlation was found between the cross-section level and the PRPT (P < .05, r = -0.330). The lower the distance to the apex, the higher the PRPT regardless of the solution used. Contrary to the advertised statement, the dental solution with a reduced surface tension did not dissolve vital pulp tissue in oval root canals any better than a conventional NaOCl solution of similar strength. Closer to the apex, pulp tissue dissolution is less efficient irrespective of the solution. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Quantifying uncertainty in carbon and nutrient pools of coarse woody debris
NASA Astrophysics Data System (ADS)
See, C. R.; Campbell, J. L.; Fraver, S.; Domke, G. M.; Harmon, M. E.; Knoepp, J. D.; Woodall, C. W.
2016-12-01
Woody detritus constitutes a major pool of both carbon and nutrients in forested ecosystems. Estimating coarse wood stocks relies on many assumptions, even when full surveys are conducted. Researchers rarely report error in coarse wood pool estimates, despite the importance to ecosystem budgets and modelling efforts. To date, no study has attempted a comprehensive assessment of error rates and uncertainty inherent in the estimation of this pool. Here, we use Monte Carlo analysis to propagate the error associated with the major sources of uncertainty present in the calculation of coarse wood carbon and nutrient (i.e., N, P, K, Ca, Mg, Na) pools. We also evaluate individual sources of error to identify the importance of each source of uncertainty in our estimates. We quantify sampling error by comparing the three most common field methods used to survey coarse wood (two transect methods and a whole-plot survey). We quantify the measurement error associated with length and diameter measurement, and technician error in species identification and decay class using plots surveyed by multiple technicians. We use previously published values of model error for the four most common methods of volume estimation: Smalian's, conical frustum, conic paraboloid, and average-of-ends. We also use previously published values for error in the collapse ratio (cross-sectional height/width) of decayed logs that serves as a surrogate for the volume remaining. We consider sampling error in chemical concentration and density for all decay classes, using distributions from both published and unpublished studies. Analytical uncertainty is calculated using standard reference plant material from the National Institute of Standards. Our results suggest that technician error in decay classification can have a large effect on uncertainty, since many of the error distributions included in the calculation (e.g. density, chemical concentration, volume-model selection, collapse ratio) are decay-class specific.
Masking of errors in transmission of VAPC-coded speech
NASA Technical Reports Server (NTRS)
Cox, Neil B.; Froese, Edwin L.
1990-01-01
A subjective evaluation is provided of the bit error sensitivity of the message elements of a Vector Adaptive Predictive (VAPC) speech coder, along with an indication of the amenability of these elements to a popular error masking strategy (cross frame hold over). As expected, a wide range of bit error sensitivity was observed. The most sensitive message components were the short term spectral information and the most significant bits of the pitch and gain indices. The cross frame hold over strategy was found to be useful for pitch and gain information, but it was not beneficial for the spectral information unless severe corruption had occurred.
NASA Astrophysics Data System (ADS)
Yun, Lingtong; Zhao, Hongzhong; Du, Mengyuan
2018-04-01
Quadrature and multi-channel amplitude-phase error have to be compensated in the I/Q quadrature sampling and signal through multi-channel. A new method that it doesn't need filter and standard signal is presented in this paper. And it can combined estimate quadrature and multi-channel amplitude-phase error. The method uses cross-correlation and amplitude ratio between the signal to estimate the two amplitude-phase errors simply and effectively. And the advantages of this method are verified by computer simulation. Finally, the superiority of the method is also verified by measure data of outfield experiments.
Uncertainties of predictions from parton distributions II: theoretical errors
NASA Astrophysics Data System (ADS)
Martin, A. D.; Roberts, R. G.; Stirling, W. J.; Thorne, R. S.
2004-06-01
We study the uncertainties in parton distributions, determined in global fits to deep inelastic and related hard scattering data, due to so-called theoretical errors. Amongst these, we include potential errors due to the change of perturbative order (NLO to NNLO), ln(1/x) and ln(1-x) effects, absorptive corrections and higher-twist contributions. We investigate these uncertainties both by including explicit corrections to our standard global analysis and by examining the sensitivity to changes of the x, Q 2, W 2 cuts on the data that are fitted. In this way we expose those kinematic regions where the conventional DGLAP description is inadequate. As a consequence we obtain a set of NLO, and of NNLO, conservative partons where the data are fully consistent with DGLAP evolution, but over a restricted kinematic domain. We also examine the potential effects of such issues as the choice of input parametrisation, heavy target corrections, assumptions about the strange quark sea and isospin violation. Hence we are able to compare the theoretical errors with those uncertainties due to errors on the experimental measurements, which we studied previously. We use W and Higgs boson production at the Tevatron and the LHC as explicit examples of the uncertainties arising from parton distributions. For many observables the theoretical error is dominant, but for the cross section for W production at the Tevatron both the theoretical and experimental uncertainties are small, and hence the NNLO prediction may serve as a valuable luminosity monitor.
Yu, Hao; Qian, Zheng; Liu, Huayi; Qu, Jiaqi
2018-02-14
This paper analyzes the measurement error, caused by the position of the current-carrying conductor, of a circular array of magnetic sensors for current measurement. The circular array of magnetic sensors is an effective approach for AC or DC non-contact measurement, as it is low-cost, light-weight, has a large linear range, wide bandwidth, and low noise. Especially, it has been claimed that such structure has excellent reduction ability for errors caused by the position of the current-carrying conductor, crosstalk current interference, shape of the conduction cross-section, and the Earth's magnetic field. However, the positions of the current-carrying conductor-including un-centeredness and un-perpendicularity-have not been analyzed in detail until now. In this paper, for the purpose of having minimum measurement error, a theoretical analysis has been proposed based on vector inner and exterior product. In the presented mathematical model of relative error, the un-center offset distance, the un-perpendicular angle, the radius of the circle, and the number of magnetic sensors are expressed in one equation. The comparison of the relative error caused by the position of the current-carrying conductor between four and eight sensors is conducted. Tunnel magnetoresistance (TMR) sensors are used in the experimental prototype to verify the mathematical model. The analysis results can be the reference to design the details of the circular array of magnetic sensors for current measurement in practical situations.
Lee, Hoo-Yeon; Hahm, Myung-Il; Lee, Sang Gyu
2018-04-04
The purpose of this study was to examine undergraduate medical students' perceptions and intentions regarding patient safety during clinical clerkships. Cross-sectional study administered in face-to-face interviews using modified the Medical Student Safety Attitudes and Professionalism Survey (MSSAPS) from three colleges of medicine in Korea. We assessed medical students' perceptions of the cultures ('safety', 'teamwork', and 'error disclosure'), 'behavioural intentions' concerning patient safety issues and 'overall patient safety'. Confirmatory factor analysis and Spearman's correlation analyses was performed. In total, 194(91.9%) of the 211 third-year undergraduate students participated. 78% of medical students reported that the quality of care received by patients was impacted by teamwork during clinical rotations. Regarding error disclosure, positive scores ranged from 10% to 74%. Except for one question asking whether the disclosure of medical errors was an important component of patient safety (74%), the percentages of positive scores for all the other questions were below 20%. 41.2% of medical students have intention to disclose it when they saw a medical error committed by another team member. Many students had difficulty speaking up about medical errors. Error disclosure guidelines and educational efforts aimed at developing sophisticated communication skills are needed. This study may serve as a reference for other institutions planning patient safety education in their curricula. Assessing student perceptions of safety culture can provide clerkship directors and clinical service chiefs with information that enhances the educational environment and promotes patient safety.
Prevalence of Refractive Errors Among School Children in Gondar Town, Northwest Ethiopia
Yared, Assefa Wolde; Belaynew, Wasie Taye; Destaye, Shiferaw; Ayanaw, Tsegaw; Zelalem, Eshete
2012-01-01
Purpose: Many children with poor vision due to refractive error remain undiagnosed and perform poorly in school. The situation is worse in the Sub-Saharan Africa, including Ethiopia, and current information is lacking. The objective of this study is to determine the prevalence of refractive error among children enrolled in elementary schools in Gondar town, Ethiopia. Materials and Methods: This was a cross-sectional study of 1852 students in 8 elementary schools. Subjects were selected by multistage random sampling. The study parameters were visual acuity (VA) evaluation and ocular examination. VA was measured by staff optometrists with the Snellen E-chart while students with subnormal vision were examined using pinhole, retinoscopy evaluation and subjective refraction by ophthalmologists. Results: The study cohort was comprised of 45.8% males and 54.2% females from 8 randomly selected elementary schools with a response rate of 93%. Refractive errors in either eye were present in 174 (9.4%) children. Of these, myopia was diagnosed in 55 (31.6%) children in the right and left eyes followed by hyperopia in 46 (26.4%) and 39 (22.4%) in the right and left eyes respectively. Low myopia was the most common refractive error in 61 (49.2%) and 68 (50%) children for the right and left eyes respectively. Conclusions: Refractive error among children is a common problem in Gondar town and needs to be assessed at every health evaluation of school children for timely treatment. PMID:23248538
Improving Dual-Task Control With a Posture-Second Strategy in Early-Stage Parkinson Disease.
Huang, Cheng-Ya; Chen, Yu-An; Hwang, Ing-Shiou; Wu, Ruey-Meei
2018-03-31
To examine the task prioritization effects on postural-suprapostural dual-task performance in patients with early-stage Parkinson disease (PD) without clinically observed postural symptoms. Cross-sectional study. Participants performed a force-matching task while standing on a mobile platform, and were instructed to focus their attention on either the postural task (posture-first strategy) or the force-matching task (posture-second strategy). University research laboratory. Individuals (N=16) with early-stage PD who had no clinically observed postural symptoms. Not applicable. Dual-task change (DTC; percent change between single-task and dual-task performance) of posture error, posture approximate entropy (ApEn), force error, and reaction time (RT). Positive DTC values indicate higher postural error, posture ApEn, force error, and force RT during dual-task conditions compared with single-task conditions. Compared with the posture-first strategy, the posture-second strategy was associated with smaller DTC of posture error and force error, and greater DTC of posture ApEn. In contrast, greater DTC of force RT was observed under the posture-second strategy. Contrary to typical recommendations, our results suggest that the posture-second strategy may be an effective dual-task strategy in patients with early-stage PD who have no clinically observed postural symptoms in order to reduce the negative effect of dual tasking on performance and facilitate postural automaticity. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Fahmy, Rania M; Aldarwesh, Amal
2018-01-01
Purpose: The purpose is to study the correlation between dry eye and refractive errors in young adults using noninvasive Keratograph. Methods: In this cross sectional study, a total of 126 participants in the age range of 19–25 years and who were free of ocular surface disease, were recruited from King Saud University Campus. Refraction was defined by the spherical equivalent (SE) as the following: 49 emmetropic eyes (±0.50 SE), 48 myopic eyes (≤−0.75 SE and above), and 31 hyperopic eyes (>+0.75 SE). All participants underwent full ophthalmic examinations assessing their refractive status and dryness level including noninvasive breakup time (NIBUT) and tear meniscus height using Keratograph 4. Results: The prevalence of dry eye was 24.6%, 36.5%, and 17.4% in emmetropes, myopes, and hypermetropes, respectively. NIBUT has a negative correlation with hyperopia and a positive correlation with myopia with a significant reduction in the average NIBUT in myopes and hypermetropes in comparison to emmetropes. Conclusion: The current results succeeded to demonstrate a correlation between refractive errors and dryness level. PMID:29676308
Study of inhaler technique in asthma patients: differences between pediatric and adult patients
Manríquez, Pablo; Acuña, Ana María; Muñoz, Luis; Reyes, Alvaro
2015-01-01
Objective: Inhaler technique comprises a set of procedures for drug delivery to the respiratory system. The oral inhalation of medications is the first-line treatment for lung diseases. Using the proper inhaler technique ensures sufficient drug deposition in the distal airways, optimizing therapeutic effects and reducing side effects. The purposes of this study were to assess inhaler technique in pediatric and adult patients with asthma; to determine the most common errors in each group of patients; and to compare the results between the two groups. Methods: This was a descriptive cross-sectional study. Using a ten-step protocol, we assessed inhaler technique in 135 pediatric asthma patients and 128 adult asthma patients. Results: The most common error among the pediatric patients was failing to execute a 10-s breath-hold after inhalation, whereas the most common error among the adult patients was failing to exhale fully before using the inhaler. Conclusions: Pediatric asthma patients appear to perform most of the inhaler technique steps correctly. However, the same does not seem to be true for adult patients. PMID:26578130
2014-01-01
Background Uncorrected Refractive Error is one of the leading cause amblyopia that exposes children to poor school performance. It refrain them from productive working lives resulting in severe economic and social loses in their latter adulthood lives. The objective of the study was to assess the prevalence of uncorrected refractive error and its associated factors among school children in Debre Markos District. Method A cross section study design was employed. Four hundred thirty two students were randomly selected using a multistage stratified sampling technique. The data were collected by trained ophthalmic nurses through interview, structured questionnaires and physical examinations. Snellens visual acuity measurement chart was used to identify the visual acuity of students. Students with visual acuity less than 6/12 had undergone further examination using auto refractor and cross-checked using spherical and cylindrical lenses. The data were entered into epi data statistical software version 3.1 and analyzed by SPSS version 20. The statistical significance was set at α ≤ 0.05. Descriptive, bivariate and multivariate analyses were done using odds ratios with 95% confidence interval. Result Out of 432 students selected for the study, 420 (97.2%) were in the age group 7–15 years. The mean age was 12 ± 2.1SD. Overall prevalence of refractive error was 43 (10.2%). Myopia was found among the most dominant 5.47% followed by astigmatism 1.9% and hyperopia 1.4% in both sexes. Female sex (AOR: 3.96, 95% CI: 1.55-10.09), higher grade level (AOR: 4.82, 95% CI: 1.98-11.47) and using computers regularly (AOR: 4.53, 95% CI: 1.58-12.96) were significantly associated with refractive error. Conclusion The burden of uncorrected refractive errors is high among primary schools children. Myopia was common in both sexes. The potential risk factors were sex, regular use of computers and higher grade level of students. Hence, school health programs should work on health information dissemination and eye health care services provision. PMID:25070579
Undergraduate paramedic students cannot do drug calculations
Eastwood, Kathryn; Boyle, Malcolm J; Williams, Brett
2012-01-01
BACKGROUND: Previous investigation of drug calculation skills of qualified paramedics has highlighted poor mathematical ability with no published studies having been undertaken on undergraduate paramedics. There are three major error classifications. Conceptual errors involve an inability to formulate an equation from information given, arithmetical errors involve an inability to operate a given equation, and finally computation errors are simple errors of addition, subtraction, division and multiplication. The objective of this study was to determine if undergraduate paramedics at a large Australia university could accurately perform common drug calculations and basic mathematical equations normally required in the workplace. METHODS: A cross-sectional study methodology using a paper-based questionnaire was administered to undergraduate paramedic students to collect demographical data, student attitudes regarding their drug calculation performance, and answers to a series of basic mathematical and drug calculation questions. Ethics approval was granted. RESULTS: The mean score of correct answers was 39.5% with one student scoring 100%, 3.3% of students (n=3) scoring greater than 90%, and 63% (n=58) scoring 50% or less, despite 62% (n=57) of the students stating they ‘did not have any drug calculations issues’. On average those who completed a minimum of year 12 Specialist Maths achieved scores over 50%. Conceptual errors made up 48.5%, arithmetical 31.1% and computational 17.4%. CONCLUSIONS: This study suggests undergraduate paramedics have deficiencies in performing accurate calculations, with conceptual errors indicating a fundamental lack of mathematical understanding. The results suggest an unacceptable level of mathematical competence to practice safely in the unpredictable prehospital environment. PMID:25215067
Gorgich, Enam Alhagh Charkhat; Barfroshan, Sanam; Ghoreishi, Gholamreza; Yaghoobi, Maryam
2016-01-01
Introduction and Aim: Medication errors as a serious problem in world and one of the most common medical errors that threaten patient safety and may lead to even death of them. The purpose of this study was to investigate the causes of medication errors and strategies to prevention of them from nurses and nursing student viewpoint. Materials & Methods: This cross-sectional descriptive study was conducted on 327 nursing staff of khatam-al-anbia hospital and 62 intern nursing students in nursing and midwifery school of Zahedan, Iran, enrolled through the availability sampling in 2015. The data were collected by the valid and reliable questionnaire. To analyze the data, descriptive statistics, T-test and ANOVA were applied by use of SPSS16 software. Findings: The results showed that the most common causes of medications errors in nursing were tiredness due increased workload (97.8%), and in nursing students were drug calculation, (77.4%). The most important way for prevention in nurses and nursing student opinion, was reducing the work pressure by increasing the personnel, proportional to the number and condition of patients and also creating a unit as medication calculation. Also there was a significant relationship between the type of ward and the mean of medication errors in two groups. Conclusion: Based on the results it is recommended that nurse-managers resolve the human resources problem, provide workshops and in-service education about preparing medications, side-effects of drugs and pharmacological knowledge. Using electronic medications cards is a measure which reduces medications errors. PMID:27045413
Benavides-Varela, S; Piva, D; Burgio, F; Passarini, L; Rolma, G; Meneghello, F; Semenza, C
2017-03-01
Arithmetical deficits in right-hemisphere damaged patients have been traditionally considered secondary to visuo-spatial impairments, although the exact relationship between the two deficits has rarely been assessed. The present study implemented a voxelwise lesion analysis among 30 right-hemisphere damaged patients and a controlled, matched-sample, cross-sectional analysis with 35 cognitively normal controls regressing three composite cognitive measures on standardized numerical measures. The results showed that patients and controls significantly differ in Number comprehension, Transcoding, and Written operations, particularly subtractions and multiplications. The percentage of patients performing below the cutoffs ranged between 27% and 47% across these tasks. Spatial errors were associated with extensive lesions in fronto-temporo-parietal regions -which frequently lead to neglect- whereas pure arithmetical errors appeared related to more confined lesions in the right angular gyrus and its proximity. Stepwise regression models consistently revealed that spatial errors were primarily predicted by composite measures of visuo-spatial attention/neglect and representational abilities. Conversely, specific errors of arithmetic nature linked to representational abilities only. Crucially, the proportion of arithmetical errors (ranging from 65% to 100% across tasks) was higher than that of spatial ones. These findings thus suggest that unilateral right hemisphere lesions can directly affect core numerical/arithmetical processes, and that right-hemisphere acalculia is not only ascribable to visuo-spatial deficits as traditionally thought. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hwang, Jee-In; Park, Hyeoun-Ae
2015-07-01
This study investigated individual and work-related factors associated with nurses' perceptions of evidence-based practice (EBP) and quality improvement (QI), and the relationships between evidence-based practice, quality improvement and clinical errors. Understanding the factors affecting evidence-based practice and quality improvement activities and their relationships with clinical errors is important for designing strategies to promote evidence-based practice, quality improvement and patient safety. A cross-sectional survey was conducted with 594 nurses in two Korean teaching hospitals using the evidence-based practice Questionnaire and quality improvement scale developed in this study. Four hundred and forty-three nurses (74.6%) returned the completed survey. Nurses' ages and educational levels were significantly associated with evidence-based practice scores whereas age and job position were associated with quality improvement scores. There were positive, moderate correlations between evidence-based practice and quality improvement scores. Nurses who had not made any clinical errors during the past 12 months had significantly higher quality improvement skills scores than those who had. The findings indicated the necessity of educational support regarding evidence-based practice and quality improvement for younger staff nurses who have no master degrees. Enhancing quality improvement skills may reduce clinical errors. Nurse managers should consider the characteristics of their staff when implementing educational and clinical strategies for evidence-based practice and quality improvement. © 2013 John Wiley & Sons Ltd.
Lee, Byung Il; Oh, Suk Hoon; Woo, Eung Je; Lee, Soo Yeol; Cho, Min Hyeong; Kwon, Ohin; Seo, Jin Keun; Baek, Woon Sik
2003-05-01
In magnetic resonance electrical impedance tomography (MREIT) we inject currents through electrodes placed on the surface of a subject and try to reconstruct cross-sectional resistivity (or conductivity) images using internal magnetic flux density as well as boundary voltage measurements. In this paper we present a static resistivity image of a cubic saline phantom (50 x 50 x 50 mm3) containing a cylindrical sausage object with an average resistivity value of 123.7 ohms cm. Our current MREIT system is based on an experimental 0.3 T MRI scanner and a current injection apparatus. We captured MR phase images of the phantom while injecting currents of 28 mA through two pairs of surface electrodes. We computed current density images from magnetic flux density images that are proportional to the MR phase images. From the current density images and boundary voltage data we reconstructed a cross-sectional resistivity image within a central region of 38.5 x 38.5 mm2 at the middle of the phantom using the J-substitution algorithm. The spatial resolution of the reconstructed image was 64 x 64 and the reconstructed average resistivity of the sausage was 117.7 ohms cm. Even though the error in the reconstructed average resistivity value was small, the relative L2-error of the reconstructed image was 25.5% due to the noise in measured MR phase images. We expect improvements in the accuracy by utilizing an MRI scanner with higher SNR and increasing the size of voxels scarifying the spatial resolution.
Nematollahi, Shahrzad; Keshteli, Ammar Hassanzadeh; Esmaillzadeh, Ahmad; Roohafza, Hamidreza; Afshar, Hamid; Adibi, Peyman; Maracy, Mohammad Reza
2017-01-01
Background: The aim of this study is to find a pathway to explaining the relations between dietary behaviors with mental health and psychological functioning. Materials and Methods: This cross-sectional study contains 4763 participants from the employees of Isfahan University of Medical Sciences. In this study, four questionnaires were administered which were provided as follows: demographic characteristics, 21-item dietary behaviors questionnaire, Hospital Anxiety and Depression Scale questionnaire, and 12-item General Health Questionnaire (GHQ-12). We started the analysis with the structural equation modeling (SEM) model with 4 unobserved latent and 16 observed variables. Results: The results show that the regression coefficient (standard error) of diet behavior on mental health and mental health on GHQ were − 1 (0.37) and 0.02 (0.01) with their P values as 0.007 and 0.01, respectively. For this model, the estimated root mean square error of approximation is 0.062 with 90% confidence interval of (0.060–0.065). In addition, the comparative fit indices (CFIs) were as 0.866 for incremental fit index and 0.866 for CFI. All these indices represent fairly good fit of the model to the data. Conclusion: We can conclude that “lower scores on diet behavior – higher scores on mental health problems” and “higher mean scores in depression and/or anxiety – higher scores in GHQ domains.” The SEM results showed that dietary behaviors have significance related to depression and/or anxiety and general health status. PMID:28349024
Prevalence and causes of blindness and low vision among adults in Fiji.
Ramke, Jacqueline; Brian, Garry; Maher, Louise; Qalo Qoqonokana, Mundi; Szetu, John
2012-07-01
To estimate the prevalence and causes of blindness and low vision among adults aged ≥40 years in Fiji. Population-based cross-sectional study. Adults aged ≥40 years in Viti Levu, Fiji. A population-based cross-sectional survey used multistage cluster random sampling to identify 34 clusters of 40 people. A cause of vision loss was determined for each eye with presenting vision worse than 6/18. Blindness (better eye presenting vision worse than 6/60), low vision (better eye presenting vision worse than 6/18, but 6/60 or better). Of 1892 people enumerated, 1381 participated (73.0%). Adjusting sample data for ethnicity, gender, age and domicile, the prevalence of blindness was 2.6% (95% confidence interval 1.7, 3.4) and low vision was 7.2% (95% confidence interval 5.9, 8.6) among adults aged ≥40 years. On multivariate analysis, being ≥70 years was a risk factor for blindness, but ethnicity, gender and urban/rural domicile were not. Being Indo-Fijian, female and older were risk factors for vision impairment (better eye presenting vision worse than 6/18). Cataract was the most common cause of bilateral blindness (71.1%). Among participants with low vision, uncorrected refractive error caused 63.3% and cataract was responsible for 25.0%. Strategies that provide accessible cataract and refractive error services producing good quality outcomes will likely have the greatest impact on reducing vision impairment. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.
A new multigroup method for cross-sections that vary rapidly in energy
NASA Astrophysics Data System (ADS)
Haut, T. S.; Ahrens, C.; Jonko, A.; Lowrie, R.; Till, A.
2017-01-01
We present a numerical method for solving the time-independent thermal radiative transfer (TRT) equation or the neutron transport (NT) equation when the opacity (cross-section) varies rapidly in frequency (energy) on the microscale ε; ε corresponds to the characteristic spacing between absorption lines or resonances, and is much smaller than the macroscopic frequency (energy) variation of interest. The approach is based on a rigorous homogenization of the TRT/NT equation in the frequency (energy) variable. Discretization of the homogenized TRT/NT equation results in a multigroup-type system, and can therefore be solved by standard methods. We demonstrate the accuracy and efficiency of the approach on three model problems. First we consider the Elsasser band model with constant temperature and a line spacing ε =10-4 . Second, we consider a neutron transport application for fast neutrons incident on iron, where the characteristic resonance spacing ε necessitates ≈ 16 , 000 energy discretization parameters if Planck-weighted cross sections are used. Third, we consider an atmospheric TRT problem for an opacity corresponding to water vapor over a frequency range 1000-2000 cm-1, where we take 12 homogeneous layers between 1-15 km, and temperature/pressure values in each layer from the standard US atmosphere. For all three problems, we demonstrate that we can achieve between 0.1 and 1 percent relative error in the solution, and with several orders of magnitude fewer parameters than a standard multigroup formulation using Planck-weighted (source-weighted) opacities for a comparable accuracy.
Uncovering the single top: observation of electroweak top quark production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benitez, Jorge Armando
2009-01-01
The top quark is generally produced in quark and anti-quark pairs. However, the Standard Model also predicts the production of only one top quark which is mediated by the electroweak interaction, known as 'Single Top'. Single Top quark production is important because it provides a unique and direct way to measure the CKM matrix element V tb, and can be used to explore physics possibilities beyond the Standard Model predictions. This dissertation presents the results of the observation of Single Top using 2.3 fb -1 of Data collected with the D0 detector at the Fermilab Tevatron collider. The analysis includes the Single Top muon+jets and electron+jets final states and employs Boosted Decision Tress as a method to separate the signal from the background. The resulting Single Top cross section measurement is: (1) σ(pmore » $$\\bar{p}$$→ tb + X, tqb + X) = 3.74 -0.74 +0.95 pb, where the errors include both statistical and systematic uncertainties. The probability to measure a cross section at this value or higher in the absence of signal is p = 1.9 x 10 -6. This corresponds to a standard deviation Gaussian equivalence of 4.6. When combining this result with two other analysis methods, the resulting cross section measurement is: (2) σ(p$$\\bar{p}$$ → tb + X, tqb + X) = 3.94 ± 0.88 pb, and the corresponding measurement significance is 5.0 standard deviations.« less
Continuous correction of differential path length factor in near-infrared spectroscopy
Moore, Jason H.; Diamond, Solomon G.
2013-01-01
Abstract. In continuous-wave near-infrared spectroscopy (CW-NIRS), changes in the concentration of oxyhemoglobin and deoxyhemoglobin can be calculated by solving a set of linear equations from the modified Beer-Lambert Law. Cross-talk error in the calculated hemodynamics can arise from inaccurate knowledge of the wavelength-dependent differential path length factor (DPF). We apply the extended Kalman filter (EKF) with a dynamical systems model to calculate relative concentration changes in oxy- and deoxyhemoglobin while simultaneously estimating relative changes in DPF. Results from simulated and experimental CW-NIRS data are compared with results from a weighted least squares (WLSQ) method. The EKF method was found to effectively correct for artificially introduced errors in DPF and to reduce the cross-talk error in simulation. With experimental CW-NIRS data, the hemodynamic estimates from EKF differ significantly from the WLSQ (p<0.001). The cross-correlations among residuals at different wavelengths were found to be significantly reduced by the EKF method compared to WLSQ in three physiologically relevant spectral bands 0.04 to 0.15 Hz, 0.15 to 0.4 Hz and 0.4 to 2.0 Hz (p<0.001). This observed reduction in residual cross-correlation is consistent with reduced cross-talk error in the hemodynamic estimates from the proposed EKF method. PMID:23640027
Continuous correction of differential path length factor in near-infrared spectroscopy
NASA Astrophysics Data System (ADS)
Talukdar, Tanveer; Moore, Jason H.; Diamond, Solomon G.
2013-05-01
In continuous-wave near-infrared spectroscopy (CW-NIRS), changes in the concentration of oxyhemoglobin and deoxyhemoglobin can be calculated by solving a set of linear equations from the modified Beer-Lambert Law. Cross-talk error in the calculated hemodynamics can arise from inaccurate knowledge of the wavelength-dependent differential path length factor (DPF). We apply the extended Kalman filter (EKF) with a dynamical systems model to calculate relative concentration changes in oxy- and deoxyhemoglobin while simultaneously estimating relative changes in DPF. Results from simulated and experimental CW-NIRS data are compared with results from a weighted least squares (WLSQ) method. The EKF method was found to effectively correct for artificially introduced errors in DPF and to reduce the cross-talk error in simulation. With experimental CW-NIRS data, the hemodynamic estimates from EKF differ significantly from the WLSQ (p<0.001). The cross-correlations among residuals at different wavelengths were found to be significantly reduced by the EKF method compared to WLSQ in three physiologically relevant spectral bands 0.04 to 0.15 Hz, 0.15 to 0.4 Hz and 0.4 to 2.0 Hz (p<0.001). This observed reduction in residual cross-correlation is consistent with reduced cross-talk error in the hemodynamic estimates from the proposed EKF method.
NASA Technical Reports Server (NTRS)
1984-01-01
The atmospheric backscatter coefficient, beta, measured with an airborne CO Laser Doppler Velocimeter (LDV) system operating in a continuous wave, focussed model is discussed. The Single Particle Mode (SPM) algorithm, was developed from concept through analysis of an extensive amount of data obtained with the system on board a NASA aircraft. The SPM algorithm is intended to be employed in situations where one particle at a time appears in the sensitive volume of the LDV. In addition to giving the backscatter coefficient, the SPM algorithm also produces as intermediate results the aerosol density and the aerosol backscatter cross section distribution. A second method, which measures only the atmospheric backscatter coefficient, is called the Volume Mode (VM) and was simultaneously employed. The results of these two methods differed by slightly less than an order of magnitude. The measurement uncertainties or other errors in the results of the two methods are examined.
Analysis of laser fluorosensor systems for remote algae detection and quantification
NASA Technical Reports Server (NTRS)
Browell, E. V.
1977-01-01
The development and performance of single- and multiple-wavelength laser fluorosensor systems for use in the remote detection and quantification of algae are discussed. The appropriate equation for the fluorescence power received by a laser fluorosensor system is derived in detail. Experimental development of a single wavelength system and a four wavelength system, which selectively excites the algae contained in the four primary algal color groups, is reviewed, and test results are presented. A comprehensive error analysis is reported which evaluates the uncertainty in the remote determination of the chlorophyll a concentration contained in algae by single- and multiple-wavelength laser fluorosensor systems. Results of the error analysis indicate that the remote quantification of chlorophyll a by a laser fluorosensor system requires optimum excitation wavelength(s), remote measurement of marine attenuation coefficients, and supplemental instrumentation to reduce uncertainties in the algal fluorescence cross sections.
Effects of sea maturity on satellite altimeter measurements
NASA Technical Reports Server (NTRS)
Glazman, Roman E.; Pilorz, Stuart H.
1990-01-01
For equilibrium and near-equilibrium sea states, the wave slope variance is a function of wind speed U and of the sea maturity. The influence of both factors on the altimeter measurements of wind speed, wave height, and radar cross section is studied experimentally on the basis of 1 year's worth of Geosat altimeter observations colocated with in situ wind and wave measurements by 20 NOAA buoys. Errors and biases in altimeter wind speed and wave height measurements are investigted. A geophysically significant error trend correlated with the sea maturity is found in wind-speed measurements. This trend is explained by examining the effect of the generalized wind fetch on the curves of the observed dependence. It is concluded that unambiguous measurements of wind speed by altimeter, in a wide range of sea states, are impossible without accounting for the actual degree of wave development.
The refractive index in electron microscopy and the errors of its approximations.
Lentzen, M
2017-05-01
In numerical calculations for electron diffraction often a simplified form of the electron-optical refractive index, linear in the electric potential, is used. In recent years improved calculation schemes have been proposed, aiming at higher accuracy by including higher-order terms of the electric potential. These schemes start from the relativistically corrected Schrödinger equation, and use a second simplified form, now for the refractive index squared, being linear in the electric potential. The second and higher-order corrections thus determined have, however, a large error, compared to those derived from the relativistically correct refractive index. The impact of the two simplifications on electron diffraction calculations is assessed through numerical comparison of the refractive index at high-angle Coulomb scattering and of cross-sections for a wide range of scattering angles, kinetic energies, and atomic numbers. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zenihiro, J.; Sakaguchi, H.; Murakami, T.
Cross sections and analyzing powers for polarized proton elastic scattering from {sup 58}Ni, and {sup 204,206,208}Pb were measured at intermediate energy E{sub p}=295 MeV. An effective relativistic Love-Franey interaction is tuned to reproduce {sup 58}Ni scattering data within the framework of the relativistic impulse approximation. The neutron densities of the lead isotopes are deduced using model-independent sum-of-Gaussians distributions. Their error envelopes are estimated by a new {chi}{sup 2} criterion including uncertainties associated with the reaction model. The systematic behaviors of extracted error envelopes of the neutron density distributions in {sup 204,206,208}Pb are presented. The extracted neutron and proton density distributionmore » of {sup 208}Pb gives a neutron skin thickness of {Delta}r{sub np}=0.211{sub -0.063}{sup +0.054} fm.« less
Westerik, Janine A. M.; Carter, Victoria; Chrystyn, Henry; Burden, Anne; Thompson, Samantha L.; Ryan, Dermot; Gruffydd-Jones, Kevin; Haughney, John; Roche, Nicolas; Lavorini, Federico; Papi, Alberto; Infantino, Antonio; Roman-Rodriguez, Miguel; Bosnic-Anticevich, Sinthia; Lisspers, Karin; Ställberg, Björn; Henrichsen, Svein Høegh; van der Molen, Thys; Hutton, Catherine; Price, David B.
2016-01-01
Abstract Objective: Correct inhaler technique is central to effective delivery of asthma therapy. The study aim was to identify factors associated with serious inhaler technique errors and their prevalence among primary care patients with asthma using the Diskus dry powder inhaler (DPI). Methods: This was a historical, multinational, cross-sectional study (2011–2013) using the iHARP database, an international initiative that includes patient- and healthcare provider-reported questionnaires from eight countries. Patients with asthma were observed for serious inhaler errors by trained healthcare providers as predefined by the iHARP steering committee. Multivariable logistic regression, stepwise reduced, was used to identify clinical characteristics and asthma-related outcomes associated with ≥1 serious errors. Results: Of 3681 patients with asthma, 623 (17%) were using a Diskus (mean [SD] age, 51 [14]; 61% women). A total of 341 (55%) patients made ≥1 serious errors. The most common errors were the failure to exhale before inhalation, insufficient breath-hold at the end of inhalation, and inhalation that was not forceful from the start. Factors significantly associated with ≥1 serious errors included asthma-related hospitalization the previous year (odds ratio [OR] 2.07; 95% confidence interval [CI], 1.26–3.40); obesity (OR 1.75; 1.17–2.63); poor asthma control the previous 4 weeks (OR 1.57; 1.04–2.36); female sex (OR 1.51; 1.08–2.10); and no inhaler technique review during the previous year (OR 1.45; 1.04–2.02). Conclusions: Patients with evidence of poor asthma control should be targeted for a review of their inhaler technique even when using a device thought to have a low error rate. PMID:26810934
Accuracy of emotion labeling in children of parents diagnosed with bipolar disorder.
Hanford, Lindsay C; Sassi, Roberto B; Hall, Geoffrey B
2016-04-01
Emotion labeling deficits have been posited as an endophenotype for bipolar disorder (BD) as they have been observed in both patients and their first-degree relatives. It remains unclear whether these deficits exist secondary to the development of psychiatric symptoms or whether they can be attributed to risk for psychopathology. To explore this, we investigated emotion processing in symptomatic and asymptomatic high-risk bipolar offspring (HRO) and healthy children of healthy parents (HCO). Symptomatic (n:18, age: 13.8 ± 2.6 years, 44% female) and asymptomatic (n:12, age: 12.8 ± 3.0 years, 42% female) HRO and age- and sex-matched HCO (n:20, age: 13.3 ± 2.5 years, 45% female) performed an emotion-labeling task. Total number of errors, emotion category and intensity of emotion error scores were compared. Correlations between total error scores and symptom severity were also investigated. Compared to HCO, both HRO groups made more errors on the adult face task (pcor=0.014). The HRO group were 2.3 times [90%CI:0.9-6.3] more likely and 4.3 times [90%CI:1.3-14.3] more likely to make errors on sad and angry faces, respectively. With the exception of sad face type errors, we observed no significant differences in error patterns between symptomatic and asymptomatic HRO, and no correlations between symptom severity and total number of errors. This study was cross-sectional in design, limiting our ability to infer trajectories or heritability of these deficits. This study provides further support for emotion labeling deficits as a candidate endophenotype for BD. Our study also suggests these deficits are not attributable to the presence of psychiatric symptoms. Copyright © 2016 Elsevier B.V. All rights reserved.
Daupin, Johanne; Atkinson, Suzanne; Bédard, Pascal; Pelchat, Véronique; Lebel, Denis; Bussières, Jean-François
2016-12-01
The medication-use system in hospitals is very complex. To improve the health professionals' awareness of the risks of errors related to the medication-use system, a simulation of medication errors was created. The main objective was to assess the medical, nursing and pharmacy staffs' ability to identify errors related to the medication-use system using a simulation. The secondary objective was to assess their level of satisfaction. This descriptive cross-sectional study was conducted in a 500-bed mother-and-child university hospital. A multidisciplinary group set up 30 situations and replicated a patient room and a care unit pharmacy. All hospital staff, including nurses, physicians, pharmacists and pharmacy technicians, was invited. Participants had to detect if a situation contained an error and fill out a response grid. They also answered a satisfaction survey. The simulation was held during 100 hours. A total of 230 professionals visited the simulation, 207 handed in a response grid and 136 answered the satisfaction survey. The participants' overall rate of correct answers was 67.5% ± 13.3% (4073/6036). Among the least detected errors were situations involving a Y-site infusion incompatibility, an oral syringe preparation and the patient's identification. Participants mainly considered the simulation as effective in identifying incorrect practices (132/136, 97.8%) and relevant to their practice (129/136, 95.6%). Most of them (114/136; 84.4%) intended to change their practices in view of their exposure to the simulation. We implemented a realistic medication-use system errors simulation in a mother-child hospital, with a wide audience. This simulation was an effective, relevant and innovative tool to raise the health care professionals' awareness of critical processes. © 2016 John Wiley & Sons, Ltd.
Eddy-Miller, Cheryl A.; Wheeler, Jerrod D.; Essaid, Hedeff I.
2009-01-01
Fish Creek, a tributary of the Snake River, is about 25 river kilometers long and is located in Teton County in western Wyoming near the town of Wilson. Local residents began observing an increase in the growth of algae and aquatic plants in the stream during the last decade. Due to the known importance of groundwater to surface water in the area, the U.S. Geological Survey (USGS), in cooperation with the Teton Conservation District, conducted a study to characterize the interactions between surface water and near-stream groundwater along Fish Creek. The study has two main objectives: (1) develop an improved spatial and temporal understanding of water flow (fluxes) between surface water and groundwater, and (2) use a two-dimensional groundwater-flow and heat-transport model to interpret observed temperature and hydraulic-head distributions and to describe groundwater flow near Fish Creek. The study is intended to augment hydrologic information derived from previously published results of a seepage investigation on Fish Creek. Seepage measurements provide spatially averaged gains and losses over an entire reach for one point in time, whereas continuous temperature and water-level measurements provide continuous estimates of gain and loss at a specific location. Stage, water-level, and temperature data were collected from surface water and from piezometers completed in an alluvial aquifer at three cross sections on Fish Creek at Teton Village, Resor's Bridge, and Wilson from October 2004 to October 2006. The flow and energy (heat) transport model VS2DH was used to simulate flow through the streambed of Fish Creek at the Teton Village cross section from April 15 to October 14, 2006, (183 recharge periods) and at the Resor's Bridge and Wilson cross sections from June 6, 2005, to October 14, 2006 (496 recharge periods). A trial-and-error technique was used to determine the best match between simulated and measured data. These results were then used to calibrate the cross-sectional models and determine horizontal and vertical hydraulic conductivities. The fluxes of groundwater into the stream or fluxes of stream water into the alluvial aquifer were estimated by using the calibrated VS2DH model for each cross section. Results of the simulations indicated that surface water/groundwater interaction and hydraulic properties were different at the three cross sections. At the most upstream cross section, Teton Village, Fish Creek flowed intermittently and continually gained relatively large quantities of water from April through September. During other times of the year, the stream was dry near the cross section. Saturated hydraulic conductivity set at 1x10-4 m/s in both the horizontal and vertical directions resulted in the best match between simulated and measured temperatures. The Resor's Bridge cross section, about midway between the other two cross sections, was near the point where perennial flow begins. At this cross section, the stream gained water from groundwater during high flow in late spring and summer, was near equilibrium with groundwater during August and September, and lost water to groundwater during the remainder of the year. Horizontal hydraulic conductivity set at 5x10-5 m/s and vertical hydraulic conductivity set at 1x10-5 m/s resulted in the best match between simulated and measured temperatures. The Wilson cross section, the most downstream site, was at USGS streamflow-gaging station 13016450. This part of the stream is perennial and was almost always gaining a small volume of water from groundwater. Saturated hydraulic conductivity set at 1x10-4 m/s in the horizontal direction and at 5x10-6 m/s in the vertical direction resulted in the best match between simulated and measured temperatures. Quantitative values of the flux from groundwater into surface water were estimated by using VS2DH and ranged from 1.1 to 6.6 cubic meters per day (m3/d) at the Teton Village cross section, from -3.8 to 7.4 m3/d at t
ERIC Educational Resources Information Center
Huprich, Julia; Green, Ravonne
2007-01-01
The Council on Public Liberal Arts Colleges (COPLAC) libraries websites were assessed for Section 508 errors using the online WebXACT tool. Only three of the twenty-one institutions (14%) had zero accessibility errors. Eighty-six percent of the COPLAC institutions had an average of 1.24 errors. Section 508 compliance is required for institutions…
NASA Astrophysics Data System (ADS)
Cools, S.; Vanroose, W.
2016-03-01
This paper improves the convergence and robustness of a multigrid-based solver for the cross sections of the driven Schrödinger equation. Adding a Coupled Channel Correction Step (CCCS) after each multigrid (MG) V-cycle efficiently removes the errors that remain after the V-cycle sweep. The combined iterative solution scheme (MG-CCCS) is shown to feature significantly improved convergence rates over the classical MG method at energies where bound states dominate the solution, resulting in a fast and scalable solution method for the complex-valued Schrödinger break-up problem for any energy regime. The proposed solver displays optimal scaling; a solution is found in a time that is linear in the number of unknowns. The method is validated on a 2D Temkin-Poet model problem, and convergence results both as a solver and preconditioner are provided to support the O (N) scalability of the method. This paper extends the applicability of the complex contour approach for far field map computation (Cools et al. (2014) [10]).
Neutrino flux prediction at MiniBooNE
NASA Astrophysics Data System (ADS)
Aguilar-Arevalo, A. A.; Anderson, C. E.; Bazarko, A. O.; Brice, S. J.; Brown, B. C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J. M.; Cox, D. C.; Curioni, A.; Djurcic, Z.; Finley, D. A.; Fleming, B. T.; Ford, R.; Garcia, F. G.; Garvey, G. T.; Green, C.; Green, J. A.; Hart, T. L.; Hawker, E.; Imlay, R.; Johnson, R. A.; Karagiorgi, G.; Kasper, P.; Katori, T.; Kobilarcik, T.; Kourbanis, I.; Koutsoliotas, S.; Laird, E. M.; Linden, S. K.; Link, J. M.; Liu, Y.; Liu, Y.; Louis, W. C.; Mahn, K. B. M.; Marsh, W.; Martin, P. S.; McGregor, G.; Metcalf, W.; Meyers, P. D.; Mills, F.; Mills, G. B.; Monroe, J.; Moore, C. D.; Nelson, R. H.; Nguyen, V. T.; Nienaber, P.; Nowak, J. A.; Ouedraogo, S.; Patterson, R. B.; Perevalov, D.; Polly, C. C.; Prebys, E.; Raaf, J. L.; Ray, H.; Roe, B. P.; Russell, A. D.; Sandberg, V.; Schirato, R.; Schmitz, D.; Shaevitz, M. H.; Shoemaker, F. C.; Smith, D.; Soderberg, M.; Sorel, M.; Spentzouris, P.; Stancu, I.; Stefanski, R. J.; Sung, M.; Tanaka, H. A.; Tayloe, R.; Tzanov, M.; van de Water, R.; Wascko, M. O.; White, D. H.; Wilking, M. J.; Yang, H. J.; Zeller, G. P.; Zimmerman, E. D.
2009-04-01
The booster neutrino experiment (MiniBooNE) searches for νμ→νe oscillations using the O(1GeV) neutrino beam produced by the booster synchrotron at the Fermi National Accelerator Laboratory). The booster delivers protons with 8 GeV kinetic energy (8.89GeV/c momentum) to a beryllium target, producing neutrinos from the decay of secondary particles in the beam line. We describe the Monte Carlo simulation methods used to estimate the flux of neutrinos from the beam line incident on the MiniBooNE detector for both polarities of the focusing horn. The simulation uses the Geant4 framework for propagating particles, accounting for electromagnetic processes and hadronic interactions in the beam line materials, as well as the decay of particles. The absolute double differential cross sections of pion and kaon production in the simulation have been tuned to match external measurements, as have the hadronic cross sections for nucleons and pions. The statistical precision of the flux predictions is enhanced through reweighting and resampling techniques. Systematic errors in the flux estimation have been determined by varying parameters within their uncertainties, accounting for correlations where appropriate.
Brinkman, D J; Tichelaar, J; Schutte, T; Benemei, S; Böttiger, Y; Chamontin, B; Christiaens, T; Likic, R; Maˇiulaitis, R; Marandi, T; Monteiro, E C; Papaioannidou, P; Pers, Y M; Pontes, C; Raskovic, A; Regenthal, R; Sanz, E J; Tamba, B I; Wilson, K; Vries, Tp de; Richir, M C; Agtmael, Ma van
2017-02-01
European medical students should have acquired adequate prescribing competencies before graduation, but it is not known whether this is the case. In this international multicenter study, we evaluated the essential knowledge, skills, and attitudes in clinical pharmacology and therapeutics (CPT) of final-year medical students across Europe. In a cross-sectional design, 26 medical schools from 17 European countries were asked to administer a standardized assessment and questionnaire to 50 final-year students. Although there were differences between schools, our results show an overall lack of essential prescribing competencies among final-year students in Europe. Students had a poor knowledge of drug interactions and contraindications, and chose inappropriate therapies for common diseases or made prescribing errors. Our results suggest that undergraduate teaching in CPT is inadequate in many European schools, leading to incompetent prescribers and potentially unsafe patient care. A European core curriculum with clear learning outcomes and assessments should be urgently developed. © 2016 The Authors. Clinical Pharmacology & Therapeutics published by Wiley Periodicals, Inc. on behalf of The American Society for Clinical Pharmacology and Therapeutics.
Body mass index, immune status, and virological control in HIV-infected men who have sex with men.
Blashill, Aaron J; Mayer, Kenneth H; Crane, Heidi M; Grasso, Chris; Safren, Steven A
2013-01-01
Prior cross-sectional studies have found inconsistent relationships between body mass index (BMI) and disease progression in HIV-infected individuals. Cross-sectional and longitudinal analyses were conducted on data from a sample of 864 HIV-infected men who have sex with men (MSM) obtained from a large, nationally distributed HIV clinical cohort. Of the 864 HIV-infected MSM, 394 (46%) were of normal weight, 363 (42%) were overweight, and 107 (12%) were obese at baseline. The baseline CD4 count was 493 (standard error [SE] = 9), with viral load (log10) = 2.4 (SE = .04), and 561 (65%) were virologically suppressed. Over time, controlling for viral load, highly active antiretroviral therapy (HAART) adherence, age, and race/ethnicity, overweight and obese HIV-infected men possessed higher CD4 counts than that of normal weight HIV-infected men. Further, overweight and obese men possessed lower viral loads than that of normal weight HIV-infected men. For HIV-infected MSM, in this longitudinal cohort study, possessing a heavier than normal BMI is longitudinally associated with improved immunological health.
High Spectral Resolution Lidar Measurements of Multiple Scattering
NASA Technical Reports Server (NTRS)
Eloranta, E. W.; Piironen, P.
1996-01-01
The University of Wisconsin High Spectral Resolution Lidar (HSRL) provides unambiguous measurements of backscatter cross section, backscatter phase function, depolarization, and optical depth. This is accomplished by dividing the lidar return into separate particulate and molecular contributions. The molecular return is then used as a calibration target. We have modified the HSRL to use an I2 molecular absorption filter to separate aerosol and molecular signals. This allows measurement in dense clouds. Useful profiles extend above the cloud base until the two way optical depth reaches values between 5 and 6; beyond this, photon counting errors become large. In order to observe multiple scattering, the HSRL includes a channel which records the combined aerosol and molecular lidar return simultaneously with the spectrometer channel measurements of optical properties. This paper describes HSRL multiple scattering measurements from both water and ice clouds. These include signal strengths and depolarizations as a function of receiver field of view. All observations include profiles of extinction and backscatter cross sections. Measurements are also compared to predictions of a multiple scattering model based on small angle approximations.
Liquid Medication Dosing Errors by Hispanic Parents: Role of Health Literacy and English Proficiency
Harris, Leslie M.; Dreyer, Benard; Mendelsohn, Alan; Bailey, Stacy C.; Sanders, Lee M.; Wolf, Michael S.; Parker, Ruth M.; Patel, Deesha A.; Kim, Kwang Youn A.; Jimenez, Jessica J.; Jacobson, Kara; Smith, Michelle; Yin, H. Shonna
2016-01-01
Objective Hispanic parents in the US are disproportionately affected by low health literacy and limited English proficiency (LEP). We examined associations between health literacy, LEP, and liquid medication dosing errors in Hispanic parents. Methods Cross-sectional analysis of data from a multisite randomized controlled experiment to identify best practices for the labeling/dosing of pediatric liquid medications (SAFE Rx for Kids study); 3 urban pediatric clinics. Analyses were limited to Hispanic parents of children <8 years, with health literacy and LEP data (n=1126). Parents were randomized to 5 groups that varied by pairing of units of measurement on the label/dosing tool. Each parent measured 9 doses [3 amounts (2.5,5,7.5 mL) using 3 tools (2 syringes (0.2,0.5 mL increment), 1 cup)] in random order. Dependent variable: Dosing error=>20% dose deviation. Predictor variables: health literacy (Newest Vital Sign) [limited=0–3; adequate=4–6], LEP (speaks English less than “very well”). Results 83.1% made dosing errors (mean(SD) errors/parent=2.2(1.9)). Parents with limited health literacy and LEP had the greatest odds of making a dosing error compared to parents with adequate health literacy who were English proficient (% trials with errors/parent=28.8 vs. 12.9%; AOR=2.2[1.7–2.8]). Parents with limited health literacy who were English proficient were also more likely to make errors (% trials with errors/parent=18.8%; AOR=1.4[1.1–1.9]). Conclusion Dosing errors are common among Hispanic parents; those with both LEP and limited health literacy are at particular risk. Further study is needed to examine how the redesign of medication labels and dosing tools could reduce literacy and language-associated disparities in dosing errors. PMID:28477800
ERIC Educational Resources Information Center
Sachse, Karoline A.; Haag, Nicole
2017-01-01
Standard errors computed according to the operational practices of international large-scale assessment studies such as the Programme for International Student Assessment's (PISA) or the Trends in International Mathematics and Science Study (TIMSS) may be biased when cross-national differential item functioning (DIF) and item parameter drift are…
Decorrelation of the true and estimated classifier errors in high-dimensional settings.
Hanczar, Blaise; Hua, Jianping; Dougherty, Edward R
2007-01-01
The aim of many microarray experiments is to build discriminatory diagnosis and prognosis models. Given the huge number of features and the small number of examples, model validity which refers to the precision of error estimation is a critical issue. Previous studies have addressed this issue via the deviation distribution (estimated error minus true error), in particular, the deterioration of cross-validation precision in high-dimensional settings where feature selection is used to mitigate the peaking phenomenon (overfitting). Because classifier design is based upon random samples, both the true and estimated errors are sample-dependent random variables, and one would expect a loss of precision if the estimated and true errors are not well correlated, so that natural questions arise as to the degree of correlation and the manner in which lack of correlation impacts error estimation. We demonstrate the effect of correlation on error precision via a decomposition of the variance of the deviation distribution, observe that the correlation is often severely decreased in high-dimensional settings, and show that the effect of high dimensionality on error estimation tends to result more from its decorrelating effects than from its impact on the variance of the estimated error. We consider the correlation between the true and estimated errors under different experimental conditions using both synthetic and real data, several feature-selection methods, different classification rules, and three error estimators commonly used (leave-one-out cross-validation, k-fold cross-validation, and .632 bootstrap). Moreover, three scenarios are considered: (1) feature selection, (2) known-feature set, and (3) all features. Only the first is of practical interest; however, the other two are needed for comparison purposes. We will observe that the true and estimated errors tend to be much more correlated in the case of a known feature set than with either feature selection or using all features, with the better correlation between the latter two showing no general trend, but differing for different models.
Systematic review of the evidence for Trails B cut-off scores in assessing fitness-to-drive.
Roy, Mononita; Molnar, Frank
2013-01-01
Fitness-to-drive guidelines recommend employing the Trail Making B Test (a.k.a. Trails B), but do not provide guidance regarding cut-off scores. There is ongoing debate regarding the optimal cut-off score on the Trails B test. The objective of this study was to address this controversy by systematically reviewing the evidence for specific Trails B cut-off scores (e.g., cut-offs in both time to completion and number of errors) with respect to fitness-to-drive. Systematic review of all prospective cohort, retrospective cohort, case-control, correlation, and cross-sectional studies reporting the ability of the Trails B to predict driving safety that were published in English-language, peer-reviewed journals. Forty-seven articles were reviewed. None of the articles justified sample sizes via formal calculations. Cut-off scores reported based on research include: 90 seconds, 133 seconds, 147 seconds, 180 seconds, and < 3 errors. There is support for the previously published Trails B cut-offs of 3 minutes or 3 errors (the '3 or 3 rule'). Major methodological limitations of this body of research were uncovered including (1) lack of justification of sample size leaving studies open to Type II error (i.e., false negative findings), and (2) excessive focus on associations rather than clinically useful cut-off scores.
Relationship between lenticular power and refractive error in children with hyperopia.
Tomomatsu, Takeshi; Kono, Shinjiro; Arimura, Shogo; Tomomatsu, Yoko; Matsumura, Takehiro; Takihara, Yuji; Inatani, Masaru; Takamura, Yoshihiro
2013-01-01
To evaluate the contribution of axial length, and lenticular and corneal power to the spherical equivalent refractive error in children with hyperopia between 3 and 13 years of age, using noncontact optical biometry. There were 62 children between 3 and 13 years of age with hyperopia (+2 diopters [D] or more) who underwent automated refraction measurement with cycloplegia, to measure spherical equivalent refractive error and corneal power. Axial length was measured using an optic biometer that does not require contact with the cornea. The refractive power of the lens was calculated using the Sanders-Retzlaff-Kraff formula. Single regression analysis was used to evaluate the correlation among the optical parameters. There was a significant positive correlation between age and axial length (P = 0.0014); however, the degree of hyperopia did not decrease with aging (P = 0.59). There was a significant negative correlation between age and the refractive power of the lens (P = 0.0001) but not that of the cornea (P = 0.43). A significant negative correlation was observed between the degree of hyperopia and lenticular power (P < 0.0001). Although this study is small scale and cross sectional, the analysis, using noncontact biometry, showed that lenticular power was negatively correlated with refractive error and age, indicating that lower lens power may contribute to the degree of hyperopia.
Social context modulates cognitive markers in Obsessive-Compulsive Disorder.
Santamaría-García, Hernando; Soriano-Mas, Carles; Burgaleta, Miguel; Ayneto, Alba; Alonso, Pino; Menchón, José M; Cardoner, Narcis; Sebastián-Gallés, Nuria
2017-08-03
Error monitoring, cognitive control and motor inhibition control are proposed as cognitive alterations disrupted in obsessive-compulsive disorder (OCD). OCD has also been associated with an increased sensitivity to social evaluations. The effect of a social simulation over electrophysiological indices of cognitive alterations in OCD was examined. A case-control cross-sectional study measuring event-related potentials (ERP) for error monitoring (Error-Related Negativity), cognitive control (N2) and motor control (LRP) was conducted. We analyzed twenty OCD patients and twenty control participants. ERP were recorded during a social game consisting of a visual discrimination task, which was performed in the presence of a simulated superior or an inferior player. Significant social effects (different ERP amplitudes in Superior vs. Inferior player conditions) were found for OCD patients, but not for controls, in all ERP components. Performing the task against a simulated inferior player reduced abnormal ERP responses in OCD to levels observed in controls. The hierarchy-induced ERP effects were accompanied effects over reaction times in OCD patients. Social context modulates signatures of abnormal cognitive functioning in OCD, therefore experiencing a social superiority position impacts over cognitive processes in OCD such as error monitoring mechanisms. These results open the door for the research of new therapeutic choices.
Focusing cosmic telescopes: systematics of strong lens modeling
NASA Astrophysics Data System (ADS)
Johnson, Traci Lin; Sharon, Keren q.
2018-01-01
The use of strong gravitational lensing by galaxy clusters has become a popular method for studying the high redshift universe. While diverse in computational methods, lens modeling techniques have grasped the means for determining statistical errors on cluster masses and magnifications. However, the systematic errors have yet to be quantified, arising from the number of constraints, availablity of spectroscopic redshifts, and various types of image configurations. I will be presenting my dissertation work on quantifying systematic errors in parametric strong lensing techniques. I have participated in the Hubble Frontier Fields lens model comparison project, using simulated clusters to compare the accuracy of various modeling techniques. I have extended this project to understanding how changing the quantity of constraints affects the mass and magnification. I will also present my recent work extending these studies to clusters in the Outer Rim Simulation. These clusters are typical of the clusters found in wide-field surveys, in mass and lensing cross-section. These clusters have fewer constraints than the HFF clusters and thus, are more susceptible to systematic errors. With the wealth of strong lensing clusters discovered in surveys such as SDSS, SPT, DES, and in the future, LSST, this work will be influential in guiding the lens modeling efforts and follow-up spectroscopic campaigns.
FastSim: A Fast Simulation for the SuperB Detector
NASA Astrophysics Data System (ADS)
Andreassen, R.; Arnaud, N.; Brown, D. N.; Burmistrov, L.; Carlson, J.; Cheng, C.-h.; Di Simone, A.; Gaponenko, I.; Manoni, E.; Perez, A.; Rama, M.; Roberts, D.; Rotondo, M.; Simi, G.; Sokoloff, M.; Suzuki, A.; Walsh, J.
2011-12-01
We have developed a parameterized (fast) simulation for detector optimization and physics reach studies of the proposed SuperB Flavor Factory in Italy. Detector components are modeled as thin sections of planes, cylinders, disks or cones. Particle-material interactions are modeled using simplified cross-sections and formulas. Active detectors are modeled using parameterized response functions. Geometry and response parameters are configured using xml files with a custom-designed schema. Reconstruction algorithms adapted from BaBar are used to build tracks and clusters. Multiple sources of background signals can be merged with primary signals. Pattern recognition errors are modeled statistically by randomly misassigning nearby tracking hits. Standard BaBar analysis tuples are used as an event output. Hadronic B meson pair events can be simulated at roughly 10Hz.
Cultural differences in survey responding: Issues and insights in the study of response biases.
Kemmelmeier, Markus
2016-12-01
This paper introduces the special section "Cultural differences in questionnaire responding" and discusses central topics in the research on response biases in cross-cultural survey research. Based on current conceptions of acquiescent, extreme, and socially desirable responding, the author considers current data on the correlated nature of response biases and the conditions under which different response styles they emerge. Based on evidence relating different response styles to the cultural dimension of individualism-collectivism, the paper explores how research presented as part of this special section might help resolves some tensions in this literature. The paper concludes by arguing that response styles should not be treated merely as measurement error, but as cultural behaviors in themselves. © 2016 International Union of Psychological Science.
Mapping Galactic 60Fe Synthesis in Cen CIR Region
NASA Astrophysics Data System (ADS)
Woosley, Stanford
2005-01-01
This included a 1 year no cost time extension. The grant was for research into the origin of radioactive 60Fe, whose detection was a mission goal for INTEGRAL and RHESSI. During the grant period, both missions ultimately discovered gamma-line emission from this long lived radioactivity at precisely the value that had been predicted years before by Timmes and Woosley (ApJ, 449,204 (1995)). Unfortunately, using "revised" stellar models and cross sections Rauscher et a1 (ApJ, 576, 323 (2002)), had meanwhile predicted a much larger value. During the grant period, Dieter Hartmann (PI on the complementary grant at Clemson) and Woosley corresponded on this discrepancy and Hartmann visited Santa Cruz (November 20 - 28,2004). All of the grant funds in NAG513659 paid for the expenses of that visit. Subsequently, partly motivated by conversations with Hartmann and Diehl, Woosley re-investigated the production of 60Fe and 26A1 in massive stars from 12 - 120 solar masses, with an eye towards determining the relevant, uncertain physics. The chief changes in Rauscher et a1 were "new" Hauser Feshbach cross sections for 59,60Fe(ng) and 26Al(np)26Mg. The latter has an experimental evaluation which was actually better represented in the study of Timmes and Woosley. The iron (ng) cross sections are from theory and the Timmes and Woosley values were just as reliable as those from Rauscher. Experiments need to be done to resolve who is right. In addition uncertainties in stellar winds, opacities and the IMF were explored. The bottom line is that the value predicted by Timmes and Woosley could well be the correct one, but the experimental error bar is larger than was realized. At least half of the uncertainty is nuclear cross sections that can, and should be measured in the laboratory.
Quantifying peak discharges for historical floods
Cook, J.L.
1987-01-01
It is usually advantageous to use information regarding historical floods, if available, to define the flood-frequency relation for a stream. Peak stages can sometimes be determined for outstanding floods that occurred many years ago before systematic gaging of streams began. In the United States, this information is usually not available for more than 100-200 years, but in countries with long cultural histories, such as China, historical flood data are available at some sites as far back as 2,000 years or more. It is important in flood studies to be able to assign a maximum discharge rate and an associated error range to the historical flood. This paper describes the significant characteristics and uncertainties of four commonly used methods for estimating the peak discharge of a flood. These methods are: (1) rating curve (stage-discharge relation) extension; (2) slope conveyance; (3) slope area; and (4) step backwater. Logarithmic extensions of rating curves are based on theoretical plotting techniques that results in straight line extensions provided that channel shape and roughness do not change significantly. The slope-conveyance and slope-area methods are based on the Manning equation, which requires specific data on channel size, shape and roughness, as well as the water-surface slope for one or more cross-sections in a relatively straight reach of channel. The slope-conveyance method is used primarily for shaping and extending rating curves, whereas the slope-area method is used for specific floods. The step-backwater method, also based on the Manning equation, requires more cross-section data than the slope-area ethod, but has a water-surface profile convergence characteristic that negates the need for known or estimated water-surface slope. Uncertainties in calculating peak discharge for historical floods may be quite large. Various investigations have shown that errors in calculating peak discharges by the slope-area method under ideal conditions for recent floods (i.e., when flood elevations, slope and channel characteristics are reasonably certain), may be on the order of 10-25%. Under less than ideal conditions, where streams are hydraulically steep and rough, errors may be much larger. The additional uncertainties for historical floods created by the passage of time may result in even larger errors of peak discharge. ?? 1987.
CLEAR: Cross-Layer Exploration for Architecting Resilience
2017-03-01
benchmark analysis, also provides cost-effective solutions (~1% additional energy cost for the same 50× improvement). This paper addresses the...core (OoO-core) [Wang 04], across 18 benchmarks . Such extensive exploration enables us to conclusively answer the above cross-layer resilience...analysis of the effects of soft errors on application benchmarks , provides a highly effective soft error resilience approach. 3. The above
Determination of Small Animal Long Bone Properties Using Densitometry
NASA Technical Reports Server (NTRS)
Breit, Gregory A.; Goldberg, BethAnn K.; Whalen, Robert T.; Hargens, Alan R. (Technical Monitor)
1996-01-01
Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased precision and repeatability. Standard deviations for the femur are consistent with those of the phantom. We conclude that in conjunction with digital image enhancement, densitometry scans are suitable for non-destructive determination of areal properties of small animal bones of comparable size to our phantom, allowing prediction of Imax and Imin within 2.5% and Theta within a fraction of a degree. This method represents a considerable extension of current methods of analyzing bone tissue distribution in small animal bones.
Furst, Cari
This article explores associate degree nursing students' experiences with lateral violence and its impact on career choice satisfaction. Lateral violence has been linked to decreased professional identity, increased errors, and poor self-esteem, leading to a negative culture and attrition. A nonexperimental, quantitative, cross-sectional, correlational design was used; 13.4 percent of respondents (n = 32) met the criteria for intermittent bullying. Analysis confirmed a significant negative correlation between experiences of lateral/vertical violence and career choice satisfaction (r = - .140, p < .05) even after controlling for affect and support. Improved efforts are needed to prevent lateral violence.
Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F; Winther-Jensen, Matilde; Nilsson, Jens C; Kjaergaard, Jesper; Møller-Sørensen, Hasse
2018-01-09
Estimation of cardiac output (CO) is essential in the treatment of circulatory unstable patients. CO measured by pulmonary artery catheter thermodilution is considered the gold standard but carries a small risk of severe complications. Stroke volume and CO can be measured by transesophageal echocardiography (TEE), which is widely used during cardiac surgery. We hypothesized that Doppler-derived CO by 3-dimensional (3D) TEE would agree well with CO measured with pulmonary artery catheter thermodilution as a reference method based on accurate measurements of the cross-sectional area of the left ventricular outflow tract. The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias (mean difference between methods), limits of agreement (equal to bias ± 2 standard deviations of the bias), and percentage error (limits of agreement divided by the mean of the 2 methods). Precision was determined for the individual methods (equal to 2 standard deviations of the bias between replicate measurements) to determine the acceptable limits of agreement. We found a good precision for Doppler-derived CO measured by 3D TEE, but although the bias for Doppler-derived CO by 3D compared to thermodilution was only 0.3 L/min (confidence interval, 0.04-0.58), there were wide limits of agreement (-1.8 to 2.5 L/min) with a percentage error of 55%. Measurements of cross-sectional area by 3D TEE had low bias of -0.27 cm (confidence interval, -0.45 to -0.08) and a percentage error of 18% compared to cardiac CT angiography. Despite low bias, the wide limits of agreement of Doppler-derived CO by 3D TEE compared to CO by thermodilution will limit clinical application and can therefore not be considered interchangeable with CO obtained by thermodilution. The lack of agreement is not explained by lack of agreement of the 3D technique.
Al Wadaani, Fahd Abdullah; Amin, Tarek Tawfik; Ali, Ayub; Khan, Atuar Rahman
2012-11-11
Some 12.8 million in the age group 5-15 years are visually impaired from uncorrected or inadequately corrected refractive errors. In Saudi Arabia, the size of this public health problem is not well defined especially among primary schoolchildren. The purpose of this cross-sectional study was to assess the prevalence and pattern of refractive errors among primary school children in Al Hassa, Saudi Arabia. A total of 2246 Saudi primary school children aged 6 to 14 years of both genders were selected using multistage sampling method form 30 primary schools located in the three different areas of Al Hassa. School children were interviewed to collect demographics and vision data using a special data collection form followed by screening for refractive errors by trained optometrists within the school premises using a standardized protocol. Assessment of visual acuity and ocular motility evaluation were carried out and cover-uncover test was performed. Children detected with defective vision were referred for further examination employing subjective refraction with auto refractometer and objective refraction using streak retinoscopy after 1% cyclopentolate. Of the screened school children (N=2002), the overall prevalence of refractive errors was 13.7% (n=274), higher among females (Odds ratio, OR=1.39, P=0.012) and significantly more among students of rural residence (OR=2.40, P=0.001). The prevalence of refractive errors was disproportionately more among those aged 12-14 years (OR=9.02, P=0.001). Only 9.4% of students with poor vision were wore spectacles for correction. Myopia was the most commonly encountered refractive error among both genders (65.7% of the total errors encountered). Uncorrected refractive errors affected a sizable portion of primary school children in Al Hassa, Saudi Arabia. Primary schoolchildren especially females, rural and older children represents high risk group for refractive errors for which the included children were unaware.
Prevalence and Pattern of Refractive Errors among Primary School Children in Al Hassa, Saudi Arabia
Wadaani, Fahd Abdullah Al; Amin, Tarek Tawfik; Ali, Ayub; Khan, Ataur Rahman
2013-01-01
Some 12.8 million in the age group 5–15 years are visually impaired from uncorrected or inadequately corrected refractive errors. In Saudi Arabia, the size of this public health problem is not well defined especially among primary schoolchildren. The purpose of this cross-sectional study was to assess the prevalence and pattern of refractive errors among primary school children in Al Hassa, Saudi Arabia. A total of 2246 Saudi primary school children aged 6 to 14 years of both genders were selected using multistage sampling method form 30 primary schools located in the three different areas of Al Hassa. School children were interviewed to collect demographics and vision data using a special data collection form followed by screening for refractive errors by trained optometrists within the school premises using a standardized protocol. Assessment of visual acuity and ocular motility evaluation were carried out and cover-uncover test was performed. Children detected with defective vision were referred for further examination employing subjective refraction with auto refractometer and objective refraction using streak retinoscopy after 1% cyclopentolate. Of the screened school children (N=2002), the overall prevalence of refractive errors was 13.7% (n=274), higher among females (Odds ratio, OR=1.39, P=0.012) and significantly more among students of rural residence (OR=2.40, P=0.001). The prevalence of refractive errors was disproportionately more among those aged 12-14 years (OR=9.02, P=0.001). Only 9.4% of students with poor vision were wore spectacles for correction. Myopia was the most commonly encountered refractive error among both genders (65.7% of the total errors encountered). Uncorrected refractive errors affected a sizable portion of primary school children in Al Hassa, Saudi Arabia. Primary schoolchildren especially females, rural and older children represents high risk group for refractive errors for which the included children were unaware. PMID:23283044
Refractive error and presbyopia among adults in Fiji.
Brian, Garry; Pearce, Matthew G; Ramke, Jacqueline
2011-04-01
To characterize refractive error, presbyopia and their correction among adults aged ≥ 40 years in Fiji, and contribute to a regional overview of these conditions. A population-based cross-sectional survey using multistage cluster random sampling. Presenting distance and near vision were measured and dilated slitlamp examination performed. The survey achieved 73.0% participation (n=1381). Presenting binocular distance vision ≥ 6/18 was achieved by 1223 participants. Another 79 had vision impaired by refractive error. Three of these were blind. At threshold 6/18, 204 participants had refractive error. Among these, 125 had spectacle-corrected presenting vision ≥ 6/18 ("met refractive error need"); 79 presented wearing no (n=74) or under-correcting (n=5) distance spectacles ("unmet refractive error need"). Presenting binocular near vision ≥ N8 was achieved by 833 participants. At threshold N8, 811 participants had presbyopia. Among these, 336 attained N8 with presenting near spectacles ("met presbyopia need"); 475 presented with no (n=402) or under-correcting (n=73) near spectacles ("unmet presbyopia need"). Rural residence was predictive of unmet refractive error (p=0.040) and presbyopia (p=0.016) need. Gender and household income source were not. Ethnicity-gender-age-domicile-adjusted to the Fiji population aged ≥ 40 years, "met refractive error need" was 10.3% (95% confidence interval [CI] 8.7-11.9%), "unmet refractive error need" was 4.8% (95%CI 3.6-5.9%), "refractive error correction coverage" was 68.3% (95%CI 54.4-82.2%),"met presbyopia need" was 24.6% (95%CI 22.4-26.9%), "unmet presbyopia need" was 33.8% (95%CI 31.3-36.3%), and "presbyopia correction coverage" was 42.2% (95%CI 37.6-46.8%). Fiji refraction and dispensing services should encourage uptake by rural dwellers and promote presbyopia correction. Lack of comparable data from neighbouring countries prevents a regional overview.
NASA Astrophysics Data System (ADS)
Honeyager, Ryan
High frequency microwave instruments are increasingly used to observe ice clouds and snow. These instruments are significantly more sensitive than conventional precipitation radar. This is ideal for analyzing ice-bearing clouds, for ice particles are tenuously distributed and have effective densities that are far less than liquid water. However, at shorter wavelengths, the electromagnetic response of ice particles is no longer solely dependent on particle mass. The shape of the ice particles also plays a significant role. Thus, in order to understand the observations of high frequency microwave radars and radiometers, it is essential to model the scattering properties of snowflakes correctly. Several research groups have proposed detailed models of snow aggregation. These particle models are coupled with computer codes that determine the particles' electromagnetic properties. However, there is a discrepancy between the particle model outputs and the requirements of the electromagnetic models. Snowflakes have countless variations in structure, but we also know that physically similar snowflakes scatter light in much the same manner. Structurally exact electromagnetic models, such as the discrete dipole approximation (DDA), require a high degree of structural resolution. Such methods are slow, spending considerable time processing redundant (i.e. useless) information. Conversely, when using techniques that incorporate too little structural information, the resultant radiative properties are not physically realistic. Then, we ask the question, what features are most important in determining scattering? This dissertation develops a general technique that can quickly parameterize the important structural aspects that determine the scattering of many diverse snowflake morphologies. A Voronoi bounding neighbor algorithm is first employed to decompose aggregates into well-defined interior and surface regions. The sensitivity of scattering to interior randomization is then examined. The loss of interior structure is found to have a negligible impact on scattering cross sections, and backscatter is lowered by approximately five percent. This establishes that detailed knowledge of interior structure is not necessary when modeling scattering behavior, and it also provides support for using an effective medium approximation to describe the interiors of snow aggregates. The Voronoi diagram-based technique enables the almost trivial determination of the effective density of this medium. A bounding neighbor algorithm is then used to establish a greatly improved approximation of scattering by equivalent spheroids. This algorithm is then used to posit a Voronoi diagram-based definition of effective density approach, which is used in concert with the T-matrix method to determine single-scattering cross sections. The resulting backscatters are found to reasonably match those of the DDA over frequencies from 10.65 to 183.31 GHz and particle sizes from a few hundred micrometers to nine millimeters in length. Integrated error in backscatter versus DDA is found to be within 25% at 94 GHz. Errors in scattering cross-sections and asymmetry parameters are likewise small. The observed cross-sectional errors are much smaller than the differences observed among different particle models. This represents a significant improvement over established techniques, and it demonstrates that the radiative properties of dense aggregate snowflakes may be adequately represented by equal-mass homogeneous spheroids. The present results can be used to supplement retrieval algorithms used by CloudSat, EarthCARE, Galileo, GPM and SWACR radars. The ability to predict the full range of scattering properties is potentially also useful for other particle regimes where a compact particle approximation is applicable.
Hybrid Reduced Order Modeling Algorithms for Reactor Physics Calculations
NASA Astrophysics Data System (ADS)
Bang, Youngsuk
Reduced order modeling (ROM) has been recognized as an indispensable approach when the engineering analysis requires many executions of high fidelity simulation codes. Examples of such engineering analyses in nuclear reactor core calculations, representing the focus of this dissertation, include the functionalization of the homogenized few-group cross-sections in terms of the various core conditions, e.g. burn-up, fuel enrichment, temperature, etc. This is done via assembly calculations which are executed many times to generate the required functionalization for use in the downstream core calculations. Other examples are sensitivity analysis used to determine important core attribute variations due to input parameter variations, and uncertainty quantification employed to estimate core attribute uncertainties originating from input parameter uncertainties. ROM constructs a surrogate model with quantifiable accuracy which can replace the original code for subsequent engineering analysis calculations. This is achieved by reducing the effective dimensionality of the input parameter, the state variable, or the output response spaces, by projection onto the so-called active subspaces. Confining the variations to the active subspace allows one to construct an ROM model of reduced complexity which can be solved more efficiently. This dissertation introduces a new algorithm to render reduction with the reduction errors bounded based on a user-defined error tolerance which represents the main challenge of existing ROM techniques. Bounding the error is the key to ensuring that the constructed ROM models are robust for all possible applications. Providing such error bounds represents one of the algorithmic contributions of this dissertation to the ROM state-of-the-art. Recognizing that ROM techniques have been developed to render reduction at different levels, e.g. the input parameter space, the state space, and the response space, this dissertation offers a set of novel hybrid ROM algorithms which can be readily integrated into existing methods and offer higher computational efficiency and defendable accuracy of the reduced models. For example, the snapshots ROM algorithm is hybridized with the range finding algorithm to render reduction in the state space, e.g. the flux in reactor calculations. In another implementation, the perturbation theory used to calculate first order derivatives of responses with respect to parameters is hybridized with a forward sensitivity analysis approach to render reduction in the parameter space. Reduction at the state and parameter spaces can be combined to render further reduction at the interface between different physics codes in a multi-physics model with the accuracy quantified in a similar manner to the single physics case. Although the proposed algorithms are generic in nature, we focus here on radiation transport models used in support of the design and analysis of nuclear reactor cores. In particular, we focus on replacing the traditional assembly calculations by ROM models to facilitate the generation of homogenized cross-sections for downstream core calculations. The implication is that assembly calculations could be done instantaneously therefore precluding the need for the expensive evaluation of the few-group cross-sections for all possible core conditions. Given the generic natures of the algorithms, we make an effort to introduce the material in a general form to allow non-nuclear engineers to benefit from this work.
Brener, Stela; Ferreira, Angela Melgaço; de Carvalho, Ricardo Vilas Freire; do Valle, Marcele Cunha Ribeiro; Souza, Helio Moraes
2012-01-01
Despite significant advances, the practice of blood transfusion is still a complex process and subject to risks. Factors that influence the safety of blood transfusion include technical skill and knowledge in hemotherapy mainly obtained by the qualification and training of teams. This study aimed to investigate the relationship between professional categories working in transfusion services of the public blood bank network in the State of Minas Gerais and their performance in proficiency tests. This was an observational cross-sectional study (2007-2008) performed using a specific instrument, based on evidence and the results of immunohematology proficiency tests as mandated by law. The error rates in ABO and RhD phenotyping, irregular antibody screening and cross-matching were 12.5%, 9.6%, 43.8% and 20.1%, respectively. When considering the number of tests performed, the error rates were 4.6%, 4.2%, 26.7% and 11.0%, respectively. The error rates varied for different professional categories: biochemists, biologists and biomedical scientists (65.0%), clinical pathology technicians (44.1%) and laboratory assistants, nursing technicians and assistant nurses (74.6%). A statistically significant difference was observed when the accuracy of clinical pathology technicians was compared with those of other professionals with only high school education (p-value < 0.001). This was not seen for professionals with university degrees (p-value = 0.293). These results reinforce the need to invest in training, improvement of educational programs, new teaching methods and tools for periodic evaluations, contributing to increase transfusion safety and improve hemotherapy in Brazil.
The prevalence of uncorrected refractive errors in underserved rural areas.
Hashemi, Hassan; Abbastabar, Hedayat; Yekta, Abbasali; Heydarian, Samira; Khabazkhoob, Mehdi
2017-12-01
To determine the prevalence of uncorrected refractive errors, need for spectacles, and the determinants of unmet need in underserved rural areas of Iran. In a cross-sectional study, multistage cluster sampling was done in 2 underserved rural areas of Iran. Then, all subjects underwent vision testing and ophthalmic examinations including the measurement of uncorrected visual acuity (UCVA), best corrected visual acuity, visual acuity with current spectacles, auto-refraction, retinoscopy, and subjective refraction. Need for spectacles was defined as UCVA worse than 20/40 in the better eye that could be corrected to better than 20/40 with suitable spectacles. Of the 3851 selected individuals, 3314 participated in the study. Among participants, 18.94% [95% confidence intervals (CI): 13.48-24.39] needed spectacles and 11.23% (95% CI: 7.57-14.89) had an unmet need. The prevalence of need for spectacles was 46.8% and 23.8% in myopic and hyperopic participants, respectively. The prevalence of unmet need was 27% in myopic, 15.8% in hyperopic, and 25.46% in astigmatic participants. Multiple logistic regression showed that education and type of refractive errors were associated with uncorrected refractive errors; the odds of uncorrected refractive errors were highest in illiterate participants, and the odds of unmet need were 12.13, 5.1, and 4.92 times higher in myopic, hyperopic and astigmatic participants as compared with emmetropic individuals. The prevalence of uncorrected refractive errors was rather high in our study. Since rural areas have less access to health care facilities, special attention to the correction of refractive errors in these areas, especially with inexpensive methods like spectacles, can prevent a major proportion of visual impairment.
Li, Zhijian; Xu, Keke; Wu, Shubin; Lv, Jia; Jin, Di; Song, Zhen; Wang, Zhongliang; Liu, Ping
2014-01-01
The prevalence of refractive error in the north of China is unknown. The study aimed to estimate the prevalence and associated factors of refractive error in school-aged children in a rural area of northern China. Cross-sectional study. The cluster random sampling method was used to select the sample. A total of 1700 subjects of 5 to 18 years of age were examined. All participants underwent ophthalmic evaluation. Refraction was performed under cycloplegia. Association of refractive errors with age, sex, and education was analysed. The main outcome measure was prevalence rates of refractive error among school-aged children. Of the 1700 responders, 1675 were eligible. The prevalence of uncorrected, presenting, and best-corrected visual acuity of 20/40 or worse in the better eye was 6.3%, 3.0% and 1.2%, respectively. The prevalence of myopia was 5.0% (84/1675, 95% CI, 4.8%-5.4%) and of hyperopia was 1.6% (27/1675, 95% CI, 1.0%-2.2%). Astigmatism was evident in 2.0% of the subjects. Myopia increased with increasing age, whereas hyperopia and astigmatism were associated with younger age. Myopia, hyperopia and astigmatism were more common in females. We also found that prevalence of refractive error were associated with education. Myopia and astigmatism were more common in those with higher degrees of education. This report has provided details of the refractive status in a rural school-aged population. Although the prevalence of refractive errors is lower in the population, the unmet need for spectacle correction remains a significant challenge for refractive eye-care services. © 2013 Royal Australian and New Zealand College of Ophthalmologists.
NASA Astrophysics Data System (ADS)
Sigurdardottir, Dorotea H.; Stearns, Jett; Glisic, Branko
2017-07-01
The deformed shape is a consequence of loading the structure and it is defined by the shape of the centroid line of the beam after deformation. The deformed shape is a universal parameter of beam-like structures. It is correlated with the curvature of the cross-section; therefore, any unusual behavior that affects the curvature is reflected through the deformed shape. Excessive deformations cause user discomfort, damage to adjacent structural members, and may ultimately lead to issues in structural safety. However, direct long-term monitoring of the deformed shape in real-life settings is challenging, and an alternative is indirect determination of the deformed shape based on curvature monitoring. The challenge of the latter is an accurate evaluation of error in the deformed shape determination, which is directly correlated with the number of sensors needed to achieve the desired accuracy. The aim of this paper is to study the deformed shape evaluated by numerical double integration of the monitored curvature distribution along the beam, and create a method to predict the associated errors and suggest the number of sensors needed to achieve the desired accuracy. The error due to the accuracy in the curvature measurement is evaluated within the scope of this work. Additionally, the error due to the numerical integration is evaluated. This error depends on the load case (i.e., the shape of the curvature diagram), the magnitude of curvature, and the density of the sensor network. The method is tested on a laboratory specimen and a real structure. In a laboratory setting, the double integration is in excellent agreement with the beam theory solution which was within the predicted error limits of the numerical integration. Consistent results are also achieved on a real structure—Streicker Bridge on Princeton University campus.
Australian children with cleft palate achieve age-appropriate speech by 5 years of age.
Chacon, Antonia; Parkin, Melissa; Broome, Kate; Purcell, Alison
2017-12-01
Children with cleft palate demonstrate atypical speech sound development, which can influence their intelligibility, literacy and learning. There is limited documentation regarding how speech sound errors change over time in cleft palate speech and the effect that these errors have upon mono-versus polysyllabic word production. The objective of this study was to examine the phonetic and phonological speech skills of children with cleft palate at ages 3 and 5. A cross-sectional observational design was used. Eligible participants were aged 3 or 5 years with a repaired cleft palate. The Diagnostic Evaluation of Articulation and Phonology (DEAP) Articulation subtest and a non-standardised list of mono- and polysyllabic words were administered once for each child. The Profile of Phonology (PROPH) was used to analyse each child's speech. N = 51 children with cleft palate participated in the study. Three-year-old children with cleft palate produced significantly more speech errors than their typically-developing peers, but no difference was apparent at 5 years. The 5-year-olds demonstrated greater phonetic and phonological accuracy than the 3-year-old children. Polysyllabic words were more affected by errors than monosyllables in the 3-year-old group only. Children with cleft palate are prone to phonetic and phonological speech errors in their preschool years. Most of these speech errors approximate typically-developing children by 5 years. At 3 years, word shape has an influence upon phonological speech accuracy. Speech pathology intervention is indicated to support the intelligibility of these children from their earliest stages of development. Copyright © 2017 Elsevier B.V. All rights reserved.
High Prevalence of Refractive Errors in 7 Year Old Children in Iran.
Hashemi, Hassan; Yekta, Abbasali; Jafarzadehpur, Ebrahim; Ostadimoghaddam, Hadi; Etemad, Koorosh; Asharlous, Amir; Nabovati, Payam; Khabazkhoob, Mehdi
2016-02-01
The latest WHO report indicates that refractive errors are the leading cause of visual impairment throughout the world. The aim of this study was to determine the prevalence of myopia, hyperopia, and astigmatism in 7 yr old children in Iran. In a cross-sectional study in 2013 with multistage cluster sampling, first graders were randomly selected from 8 cities in Iran. All children were tested by an optometrist for uncorrected and corrected vision, and non-cycloplegic and cycloplegic refraction. Refractive errors in this study were determined based on spherical equivalent (SE) cyloplegic refraction. From 4614 selected children, 89.0% participated in the study, and 4072 were eligible. The prevalence rates of myopia, hyperopia and astigmatism were 3.04% (95% CI: 2.30-3.78), 6.20% (95% CI: 5.27-7.14), and 17.43% (95% CI: 15.39-19.46), respectively. Prevalence of myopia (P=0.925) and astigmatism (P=0.056) were not statistically significantly different between the two genders, but the odds of hyperopia were 1.11 (95% CI: 1.01-2.05) times higher in girls (P=0.011). The prevalence of with-the-rule astigmatism was 12.59%, against-the-rule was 2.07%, and oblique 2.65%. Overall, 22.8% (95% CI: 19.7-24.9) of the schoolchildren in this study had at least one type of refractive error. One out of every 5 schoolchildren had some refractive error. Conducting multicenter studies throughout the Middle East can be very helpful in understanding the current distribution patterns and etiology of refractive errors compared to the previous decade.
Prevalence of refractive error in Europe: the European Eye Epidemiology (E(3)) Consortium.
Williams, Katie M; Verhoeven, Virginie J M; Cumberland, Phillippa; Bertelsen, Geir; Wolfram, Christian; Buitendijk, Gabriëlle H S; Hofman, Albert; van Duijn, Cornelia M; Vingerling, Johannes R; Kuijpers, Robert W A M; Höhn, René; Mirshahi, Alireza; Khawaja, Anthony P; Luben, Robert N; Erke, Maja Gran; von Hanno, Therese; Mahroo, Omar; Hogg, Ruth; Gieger, Christian; Cougnard-Grégoire, Audrey; Anastasopoulos, Eleftherios; Bron, Alain; Dartigues, Jean-François; Korobelnik, Jean-François; Creuzot-Garcher, Catherine; Topouzis, Fotis; Delcourt, Cécile; Rahi, Jugnoo; Meitinger, Thomas; Fletcher, Astrid; Foster, Paul J; Pfeiffer, Norbert; Klaver, Caroline C W; Hammond, Christopher J
2015-04-01
To estimate the prevalence of refractive error in adults across Europe. Refractive data (mean spherical equivalent) collected between 1990 and 2013 from fifteen population-based cohort and cross-sectional studies of the European Eye Epidemiology (E(3)) Consortium were combined in a random effects meta-analysis stratified by 5-year age intervals and gender. Participants were excluded if they were identified as having had cataract surgery, retinal detachment, refractive surgery or other factors that might influence refraction. Estimates of refractive error prevalence were obtained including the following classifications: myopia ≤-0.75 diopters (D), high myopia ≤-6D, hyperopia ≥1D and astigmatism ≥1D. Meta-analysis of refractive error was performed for 61,946 individuals from fifteen studies with median age ranging from 44 to 81 and minimal ethnic variation (98 % European ancestry). The age-standardised prevalences (using the 2010 European Standard Population, limited to those ≥25 and <90 years old) were: myopia 30.6 % [95 % confidence interval (CI) 30.4-30.9], high myopia 2.7 % (95 % CI 2.69-2.73), hyperopia 25.2 % (95 % CI 25.0-25.4) and astigmatism 23.9 % (95 % CI 23.7-24.1). Age-specific estimates revealed a high prevalence of myopia in younger participants [47.2 % (CI 41.8-52.5) in 25-29 years-olds]. Refractive error affects just over a half of European adults. The greatest burden of refractive error is due to myopia, with high prevalence rates in young adults. Using the 2010 European population estimates, we estimate there are 227.2 million people with myopia across Europe.
Marmamula, Srinivas; Keeffe, Jill E; Rao, Gullapalli N
2009-01-01
To investigate the prevalence of uncorrected refractive errors, presbyopia and spectacle coverage in subjects aged 15-50 years using rapid assessment methodology in the Mahabubnagar district of Andhra Pradesh, India. A population-based cross sectional study was conducted using cluster random sampling to enumerate 3,300 subjects from 55 clusters. Unaided, aided and pinhole visual acuity was assessed using a LogMAR chart at a distance of 4 meters. Near vision was assessed using N notation chart. Uncorrected refractive error was defined as presenting visual acuity worse than 6/12 but improving to at least 6/12 or better on using a pinhole. Presbyopia is defined as binocular near vision worse than N8 in subjects aged more than 35 years with binocular distance visual acuity of 6/12 or better. Of the 3,300 subjects enumerated from 55 clusters, 3,203 (97%) subjects were available for examination. Of these, 1,496 (46.7%) were females and 930 (29%) were > or = 40 years. Age and gender adjusted prevalence of uncorrected refractive errors causing visual impairment in the better eye was 2.7% (95% CI, 2.1-3.2%). Presbyopia was present in 690 (63.7%, 95% CI, 60.8-66.6%) subjects aged over 35 years. Spectacle coverage for refractive error was 29% and for presbyopia it was 19%. There is a large unmet need for refractive correction in this area in India. Rapid assessment methods are an effective means of assessing the need for services and the impact of models of care.
Clawson, Ann; Clayson, Peter E; Keith, Cierra M; Catron, Christina; Larson, Michael J
2017-03-01
Cognitive control includes higher-level cognitive processes used to evaluate environmental conflict. Given the importance of cognitive control in regulating behavior, understanding the developmental course of these processes may contribute to a greater understanding of normal and abnormal development. We examined behavioral (response times [RTs], error rates) and event-related potential data (N2, error-related negativity [ERN], correct-response negativity [CRN], error positivity [Pe]) during a flanker task in cross-sectional groups of 45 youth (ages 8-18), 52 younger adults (ages 20-28), and 58 older adults (ages 56-91). Younger adults displayed the most efficient processing, including significantly reduced CRN and N2 amplitude, increased Pe amplitude, and significantly better task performance than youth or older adults (e.g., faster RTs, fewer errors). Youth displayed larger CRN and N2, attenuated Pe, and significantly worse task performance than younger adults. Older adults fell either between youth and younger adults (e.g., CRN amplitudes, N2 amplitudes) or displayed neural and behavioral performance that was similar to youth (e.g., Pe amplitudes, error rates). These findings point to underdeveloped neural and cognitive processes early in life and reduced efficiency in older adulthood, contributing to poor implementation and modulation of cognitive control in response to conflict. Thus, cognitive control processing appears to reach peak performance and efficiency in younger adulthood, marked by improved task performance with less neural activation. Copyright © 2017 Elsevier B.V. All rights reserved.
The prevalence of refractive errors in 6- to 15-year-old schoolchildren in Dezful, Iran.
Norouzirad, Reza; Hashemi, Hassan; Yekta, Abbasali; Nirouzad, Fereidon; Ostadimoghaddam, Hadi; Yazdani, Negareh; Dadbin, Nooshin; Javaherforoushzadeh, Ali; Khabazkhoob, Mehdi
2015-01-01
To determine the prevalence of refractive errors, among 6- to 15-year-old schoolchildren in the city of Dezful in western Iran. In this cross-sectional study, 1375 Dezful schoolchildren were selected through multistage cluster sampling. After obtaining written consent, participants had uncorrected and corrected visual acuity tests and cycloplegic refraction at the school site. Refractive errors were defined as myopia [spherical equivalent (SE) -0.5 diopter (D)], hyperopia (SE ≥ 2.0D), and astigmatism (cylinder error > 0.5D). 1151 (83.7%) schoolchildren participated in the study. Of these, 1130 completed their examinations. 21 individuals were excluded because of poor cooperation and contraindication for cycloplegic refraction. Prevalence of myopia, hyperopia, and astigmatism were 14.9% (95% confidence interval (CI): 10.1-19.6), 12.9% (95% CI: 7.2-18.6), and 45.3% (95% CI: 40.3-50.3), respectively. Multiple logistic regression analysis showed an age-related increase in myopia prevalence (p < 0.001) and a decrease in hyperopia prevalence (p < 0.001). There was a higher prevalence of myopia in boys (p<0.001) and hyperopia in girls (p = 0.007). This study showed a considerably high prevalence of refractive errors among the Iranian population of schoolchildren in Dezful in the west of Iran. The prevalence of myopia is considerably high compared to previous studies in Iran and increases with age.
Peripheral refraction in normal infant rhesus monkeys
Hung, Li-Fang; Ramamirtham, Ramkumar; Huang, Juan; Qiao-Grider, Ying; Smith, Earl L.
2008-01-01
Purpose To characterize peripheral refractions in infant monkeys. Methods Cross-sectional data for horizontal refractions were obtained from 58 normal rhesus monkeys at 3 weeks of age. Longitudinal data were obtained for both the vertical and horizontal meridians from 17 monkeys. Refractive errors were measured by retinoscopy along the pupillary axis and at eccentricities of 15, 30, and 45 degrees. Axial dimensions and corneal power were measured by ultrasonography and keratometry, respectively. Results In infant monkeys, the degree of radial astigmatism increased symmetrically with eccentricity in all meridians. There were, however, initial nasal-temporal and superior-inferior asymmetries in the spherical-equivalent refractive errors. Specifically, the refractions in the temporal and superior fields were similar to the central ametropia, but the refractions in the nasal and inferior fields were more myopic than the central ametropia and the relative nasal field myopia increased with the degree of central hyperopia. With age, the degree of radial astigmatism decreased in all meridians and the refractions became more symmetrical along both the horizontal and vertical meridians; small degrees of relative myopia were evident in all fields. Conclusions As in adult humans, refractive error varied as a function of eccentricity in infant monkeys and the pattern of peripheral refraction varied with the central refractive error. With age, emmetropization occurred for both central and peripheral refractive errors resulting in similar refractions across the central 45 degrees of the visual field, which may reflect the actions of vision-dependent, growth-control mechanisms operating over a wide area of the posterior globe. PMID:18487366
NASA Astrophysics Data System (ADS)
Geoghegan, P. H.; Buchmann, N. A.; Spence, C. J. T.; Moore, S.; Jermy, M.
2012-05-01
A method for the construction of both rigid and compliant (flexible) transparent flow phantoms of biological flow structures, suitable for PIV and other optical flow methods with refractive-index-matched working fluid is described in detail. Methods for matching the in vivo compliance and elastic wave propagation wavelength are presented. The manipulation of MRI and CT scan data through an investment casting mould is described. A method for the casting of bubble-free phantoms in silicone elastomer is given. The method is applied to fabricate flexible phantoms of the carotid artery (with and without stenosis), the carotid artery bifurcation (idealised and patient-specific) and the human upper airway (nasal cavity). The fidelity of the phantoms to the original scan data is measured, and it is shown that the cross-sectional error is less than 5% for phantoms of simple shape but up to 16% for complex cross-sectional shapes such as the nasal cavity. This error is mainly due to the application of a PVA coating to the inner mould and can be reduced by shrinking the digital model. Sixteen per cent variation in area is less than the natural patient to patient variation of the physiological geometries. The compliance of the phantom walls is controlled within physiologically realistic ranges, by choice of the wall thickness, transmural pressure and Young's modulus of the elastomer. Data for the dependence of Young's modulus on curing temperature are given for Sylgard 184. Data for the temperature dependence of density, viscosity and refractive index of the refractive-index-matched working liquid (i.e. water-glycerol mixtures) are also presented.
Relph, Nicola; Herrington, Lee
2016-12-01
Following an ACL injury, reconstruction (ACL-R) and rehabilitation, athletes may return to play with a proprioceptive deficit. However, literature is lacking to support this hypothesis in elite athletic groups who have returned to international levels of performance. It is possible the potentially heightened proprioceptive ability evidenced in athletes may negate a deficit following injury. The purpose of this study was to consider the effects of ACL injury, reconstruction and rehabilitation on knee joint position sense (JPS) on a group of elite athletes who had returned to international performance. Using a cross-sectional design ten elite athletes with ACL-R and ten controls were evaluated. JPS was tested into knee extension and flexion using absolute error scores. Average data with 95% confidence intervals between the reconstructed, contralateral and uninjured control knees were analyzed using t-tests and effect sizes. The reconstructed knee of the injured group demonstrated significantly greater angle of error scores when compared to the contralateral and uninjured control into knee flexion (p=0.0001, r=0.98) and knee extension (p=0.0001, r=0.91). There were no significant differences between the contralateral uninjured knee of the injured group and the uninjured control group. Elite athletes who have had an ACL injury, reconstruction, rehabilitation and returned to international play demonstrate lower JPS ability compared to control groups. It is unclear if this deficiency affects long-term performance or secondary injury and re-injury problems. In the future physical therapists should monitor athletes longitudinally when they return to play. Copyright © 2016 Elsevier B.V. All rights reserved.
Automated abdominal plane and circumference estimation in 3D US for fetal screening
NASA Astrophysics Data System (ADS)
Lorenz, C.; Brosch, T.; Ciofolo-Veit, C.; Klinder, T.; Lefevre, T.; Cavallaro, A.; Salim, I.; Papageorghiou, A. T.; Raynaud, C.; Roundhill, D.; Rouet, L.; Schadewaldt, N.; Schmidt-Richberg, A.
2018-03-01
Ultrasound is increasingly becoming a 3D modality. Mechanical and matrix array transducers are able to deliver 3D images with good spatial and temporal resolution. The 3D imaging facilitates the application of automated image analysis to enhance workflows, which has the potential to make ultrasound a less operator dependent modality. However, the analysis of the more complex 3D images and definition of all examination standards on 2D images pose barriers to the use of 3D in daily clinical practice. In this paper, we address a part of the canonical fetal screening program, namely the localization of the abdominal cross-sectional plane with the corresponding measurement of the abdominal circumference in this plane. For this purpose, a fully automated pipeline has been designed starting with a random forest based anatomical landmark detection. A feature trained shape model of the fetal torso including inner organs with the abdominal cross-sectional plane encoded into the model is then transformed into the patient space using the landmark localizations. In a free-form deformation step, the model is individualized to the image, using a torso probability map generated by a convolutional neural network as an additional feature image. After adaptation, the abdominal plane and the abdominal torso contour in that plane are directly obtained. This allows the measurement of the abdominal circumference as well as the rendering of the plane for visual assessment. The method has been trained on 126 and evaluated on 42 abdominal 3D US datasets. An average plane offset error of 5.8 mm and an average relative circumference error of 4.9 % in the evaluation set could be achieved.
Hersh, Beverly; D'Auria, Jennifer; Scott, Michael; Fowler, John R
2018-05-01
Ultrasound (US) measurement of cross-sectional area (CSA) of the median nerve has emerged as a viable alternative to electromyography/nerve conduction studies (EMG/NCS) for diagnosis of carpal tunnel syndrome (CTS). The purpose of this study is to compare CSA of the median nerve between US and MRI using current MRI and US technology. The null hypothesis is there is no difference between US and MRI CSA measurements. The study design was an observational cohort, enrolling patients presenting to clinic with MRI of the wrist. Participants with clinical signs and symptoms of CTS were excluded. The CSA measurements of the median nerve on MRI T1-weighted axial images were performed by a hand fellow blinded to results of US measurements, and US measurement of median nerve CSA was performed by a hand fellowship trained surgeon blinded to results of the MRI measurements. Results were analyzed via percent error, Pearson correlation, and t tests. Twenty participants were enrolled with mean age of 29.4 years. Four left wrists and 16 right wrists were measured. The US mean CSA of the median nerve was 6.8 mm 2 (±2.330 mm 2 ). The MRI mean CSA of the median nerve was 6.8 mm 2 (±2.153 mm 2 ), P = .442. Pearson correlation between modalities was 0.93, suggesting near-perfect correlation. Mean percent error was 8.8%. Results of this study suggest that US is an accurate method to measure CSA of the median nerve at the carpal tunnel inlet. The mean difference between US and MRI was unlikely to be clinically significant.
Santos, Vagner Dos; Silva, Paulo Henrique Dourado da; Gandolfi, Lenora
2017-09-25
To estimate the past-year prevalence of parental use of verbal and physical discipline in an urban sample. A cross-sectional study was conducted in two underprivileged neighborhoods with nearly 80,000 inhabitants. Complex sampling was used. The households were selected by applying two-stage probabilistic sampling with stratification. A total of 401 households (sample error=0.1) were selected by maximizing the variance (p=0.5). The cluster sampling indicated 33 census units (sample error=0.05). The Brazilian Portuguese version of the WorldSAFE Core Questionnaire was used to assess parental use of moderate verbal discipline, harsh verbal discipline, moderate physical discipline, and harsh physical discipline. This questionnaire asks how often mothers (respondent) and/or their husband or partner use specific disciplinary tactics. The mean age of children and adolescents was 9 years (SD: 4.5). The prevalence of harsh verbal discipline was approximately 37% (28.3% [95% CI: 23.4-33.3%] for more than three times). The prevalence of harsh physical discipline was approximately 30% (21.8% [CI: 18.2-25.4%] for more than three times). Boys had higher odds of receiving harsh physical discipline [OR: 1.56, p<0.05]. Children and adolescents with learning problems and developmental delays had higher odds of being exposed to harsh discipline than their peers without these problems. Children and adolescents with chronic health conditions (e.g., asthma) had lower odds of receiving harsh physical discipline (OR: 0.4; p<0.05). Parental abuse was embedded within CA rearing practices in these two underprivileged neighborhoods. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Noyer, Aurelien L; Esteves, Jorge E; Thomson, Oliver P
2017-01-01
Diagnostic reasoning refers to the cognitive processes by which clinicians formulate diagnoses. Despite the implications for patient safety and professional identity, research on diagnostic reasoning in osteopathy remains largely theoretical. The aim of this study was to investigate the influence of perceived task difficulty on the diagnostic reasoning of students osteopaths. Using a single-blinded, cross sectional study design, sixteen final year pre-registration osteopathy students diagnosed two standardized cases under two context conditions (complex versus control). Context difficulty was manipulated via verbal manipulation and case order was randomized and counterbalanced across subjects to ensure that each case was diagnosed evenly under both conditions (i.e. half of the subjects performed either case A or B first). After diagnosis, participants were presented with items (literal, inferred and filler) designed to represent analytical and non-analytical reasoning. Response time and error rate for each item were measured. A repeated measures analysis of variance (concept type x context) was performed to identify differences across conditions and make inferences on diagnostic reasoning. Participants made significantly more errors when judging literal concepts and took significantly less time to recognize filler concepts in the complex context. No significant difference in ability to judge inferred concepts across contexts was found. Although speculative and preliminary, our findings suggest the perception of complexity led to an increased reliance on analytical reasoning at the detriment of non-analytical reasoning. To reduce the associated cognitive load, osteopathic educational institutions could consider developing the intuitive diagnostic capabilities of pre-registration students. Postgraduate mentorship opportunities could be considered to enhance the diagnostic reasoning of professional osteopaths, particularly recent graduates. Further research exploring the influence of expertise is required to enhance the validity of this study.
A study of modelling simplifications in ground vibration predictions for railway traffic at grade
NASA Astrophysics Data System (ADS)
Germonpré, M.; Degrande, G.; Lombaert, G.
2017-10-01
Accurate computational models are required to predict ground-borne vibration due to railway traffic. Such models generally require a substantial computational effort. Therefore, much research has focused on developing computationally efficient methods, by either exploiting the regularity of the problem geometry in the direction along the track or assuming a simplified track structure. This paper investigates the modelling errors caused by commonly made simplifications of the track geometry. A case study is presented investigating a ballasted track in an excavation. The soil underneath the ballast is stiffened by a lime treatment. First, periodic track models with different cross sections are analyzed, revealing that a prediction of the rail receptance only requires an accurate representation of the soil layering directly underneath the ballast. A much more detailed representation of the cross sectional geometry is required, however, to calculate vibration transfer from track to free field. Second, simplifications in the longitudinal track direction are investigated by comparing 2.5D and periodic track models. This comparison shows that the 2.5D model slightly overestimates the track stiffness, while the transfer functions between track and free field are well predicted. Using a 2.5D model to predict the response during a train passage leads to an overestimation of both train-track interaction forces and free field vibrations. A combined periodic/2.5D approach is therefore proposed in this paper. First, the dynamic axle loads are computed by solving the train-track interaction problem with a periodic model. Next, the vibration transfer to the free field is computed with a 2.5D model. This combined periodic/2.5D approach only introduces small modelling errors compared to an approach in which a periodic model is used in both steps, while significantly reducing the computational cost.
NASA Astrophysics Data System (ADS)
Wear, James A.
Measurements of the production cross section sigma (e^+e^-to Z to hadrons) have been made with the ALEPH detector in a seven-point energy scan across the Z resonance at the LEP e^+e^ - collider. The selection of hadronic Z decays is performed with a systematic uncertainty of 0.3%, resulting in 147,836 events. The absolute luminosity has been determined with a systematic uncertainty of 0.9%. These hadronic cross sections and ALEPH's measurement of Z decay into charged leptons, sigma(e^+e^ -to Z to l^+l^ -), are used in fits to extract parameters of the Z resonance in a model-independent way. The Z mass and total width are measured to be M_{Z } = 91.177 +/- 0.010 _{exp} +/- 0.020_{LEP} GeV and Gamma_{Z} = 2.482 +/- 0.018_{exp} +/- 0.006_{LEP } GeV where the second errors are due to LEP beam energy uncertainties. The Z decay partial widths are measured to be Gamma_{h} = 1.738 +/- 0.016 GeV, Gamma_{l} = 83.45 +/- 0.76 MeV, and Gamma_ {inv} = 0.493 +/- 0.015 GeV. The Born-level peak hadronic cross section is sigma_sp{had}{0 } = 41.58 +/- 0.44 nb, R = Gamma_{h }/Gamma_{l} = 20.83 +/- 0.21, and Gamma_{inv}/Gamma _{l} = 5.91 +/- 0.18. The number of light neutrino generations is determined to be N_{nu} = 2.96 +/- 0.09 and the Standard Model electroweak mixing angle to be sin^2 theta_{W} = 0.2325 +/- 0.0027.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dawson, William A., E-mail: wadawson@ucdavis.edu
2013-08-01
Merging galaxy clusters have become one of the most important probes of dark matter, providing evidence for dark matter over modified gravity and even constraints on the dark matter self-interaction cross-section. To properly constrain the dark matter cross-section it is necessary to understand the dynamics of the merger, as the inferred cross-section is a function of both the velocity of the collision and the observed time since collision. While the best understanding of merging system dynamics comes from N-body simulations, these are computationally intensive and often explore only a limited volume of the merger phase space allowed by observed parametermore » uncertainty. Simple analytic models exist but the assumptions of these methods invalidate their results near the collision time, plus error propagation of the highly correlated merger parameters is unfeasible. To address these weaknesses I develop a Monte Carlo method to discern the properties of dissociative mergers and propagate the uncertainty of the measured cluster parameters in an accurate and Bayesian manner. I introduce this method, verify it against an existing hydrodynamic N-body simulation, and apply it to two known dissociative mergers: 1ES 0657-558 (Bullet Cluster) and DLSCL J0916.2+2951 (Musket Ball Cluster). I find that this method surpasses existing analytic models-providing accurate (10% level) dynamic parameter and uncertainty estimates throughout the merger history. This, coupled with minimal required a priori information (subcluster mass, redshift, and projected separation) and relatively fast computation ({approx}6 CPU hours), makes this method ideal for large samples of dissociative merging clusters.« less
NASA Technical Reports Server (NTRS)
Smith, Brandon D.; Boyd, Iain D.; Kamhawi, Hani
2014-01-01
The sensitivity of xenon ionization rates to collision cross-sections is studied within the framework of a hybrid-PIC model of a Hall thruster discharge. A revised curve fit based on the Drawin form is proposed and is shown to better reproduce the measured crosssections at high electron energies, with differences in the integrated rate coefficients being on the order of 10% for electron temperatures between 20 eV and 30 eV. The revised fit is implemented into HPHall and the updated model is used to simulate NASA's HiVHAc EDU2 Hall thruster at discharge voltages of 300, 400, and 500 V. For all three operating points, the revised cross-sections result in an increase in the predicted thrust and anode efficiency, reducing the error relative to experimental performance measurements. Electron temperature and ionization reaction rates are shown to follow the trends expected based on the integrated rate coefficients. The effects of triply-charged xenon are also assessed. The predicted thruster performance is found to have little or no dependence on the presence of triply-charged ions. The fraction of ion current carried by triply-charged ions is found to be on the order of 1% and increases slightly with increasing discharge voltage. The reaction rates for the 0?III, I?III, and II?III ionization reactions are found to be of similar order of magnitude and are about one order of magnitude smaller than the rate of 0?II ionization in the discharge channel.
Geometry effect on electrokinetic flow and ionic conductance in pH-regulated nanochannels
NASA Astrophysics Data System (ADS)
Sadeghi, Morteza; Saidi, Mohammad Hassan; Moosavi, Ali; Sadeghi, Arman
2017-12-01
Semi-analytical solutions are obtained for the electrical potential, electroosmotic velocity, ionic conductance, and surface physicochemical properties associated with long pH-regulated nanochannels of arbitrary but constant cross-sectional area. The effects of electric double layer overlap, multiple ionic species, and surface association/dissociation reactions are all taken into account, assuming low surface potentials. The method of analysis includes series solutions which the pertinent coefficients are obtained by applying the wall boundary conditions using either of the least-squares or point matching techniques. Although the procedure is general enough to be applied to almost any arbitrary cross section, nine nanogeometries including polygonal, trapezoidal, double-trapezoidal, rectangular, elliptical, semi-elliptical, isosceles triangular, rhombic, and isotropically etched profiles are selected for presentation. For the special case of an elliptic cross section, full analytical solutions are also obtained utilizing the Mathieu functions. We show that the geometrical configuration plays a key role in determination of the ionic conductance, surface charge density, electrical potential and velocity fields, and proton enhancement. In this respect, the net electric charge and convective ionic conductance are higher for channels of larger perimeter to area ratio, whereas the opposite is true for the average surface charge density and mean velocity; the geometry impact on the two latest ones, however, vanishes if the background salt concentration is high enough. Moreover, we demonstrate that considering a constant surface potential equal to the average charge-regulated potential provides sufficiently accurate results for smooth geometries such as an ellipse at medium-high aspect ratios but leads to significant errors for geometries having narrow corners such as a triangle.
Zaker, Neda; Zehtabian, Mehdi; Sina, Sedigheh; Koontz, Craig; Meigooni, Ali S
2016-03-08
Monte Carlo simulations are widely used for calculation of the dosimetric parameters of brachytherapy sources. MCNP4C2, MCNP5, MCNPX, EGS4, EGSnrc, PTRAN, and GEANT4 are among the most commonly used codes in this field. Each of these codes utilizes a cross-sectional library for the purpose of simulating different elements and materials with complex chemical compositions. The accuracies of the final outcomes of these simulations are very sensitive to the accuracies of the cross-sectional libraries. Several investigators have shown that inaccuracies of some of the cross section files have led to errors in 125I and 103Pd parameters. The purpose of this study is to compare the dosimetric parameters of sample brachytherapy sources, calculated with three different versions of the MCNP code - MCNP4C, MCNP5, and MCNPX. In these simulations for each source type, the source and phantom geometries, as well as the number of the photons, were kept identical, thus eliminating the possible uncertainties. The results of these investigations indicate that for low-energy sources such as 125I and 103Pd there are discrepancies in gL(r) values. Discrepancies up to 21.7% and 28% are observed between MCNP4C and other codes at a distance of 6 cm for 103Pd and 10 cm for 125I from the source, respectively. However, for higher energy sources, the discrepancies in gL(r) values are less than 1.1% for 192Ir and less than 1.2% for 137Cs between the three codes.
Interobserver delineation variation in lung tumour stereotactic body radiotherapy
Persson, G F; Nygaard, D E; Hollensen, C; Munck af Rosenschöld, P; Mouritsen, L S; Due, A K; Berthelsen, A K; Nyman, J; Markova, E; Roed, A P; Roed, H; Korreman, S; Specht, L
2012-01-01
Objectives In radiotherapy, delineation uncertainties are important as they contribute to systematic errors and can lead to geographical miss of the target. For margin computation, standard deviations (SDs) of all uncertainties must be included as SDs. The aim of this study was to quantify the interobserver delineation variation for stereotactic body radiotherapy (SBRT) of peripheral lung tumours using a cross-sectional study design. Methods 22 consecutive patients with 26 tumours were included. Positron emission tomography/CT scans were acquired for planning of SBRT. Three oncologists and three radiologists independently delineated the gross tumour volume. The interobserver variation was calculated as a mean of multiple SDs of distances to a reference contour, and calculated for the transversal plane (SDtrans) and craniocaudal (CC) direction (SDcc) separately. Concordance indexes and volume deviations were also calculated. Results Median tumour volume was 13.0 cm3, ranging from 0.3 to 60.4 cm3. The mean SDtrans was 0.15 cm (SD 0.08 cm) and the overall mean SDcc was 0.26 cm (SD 0.15 cm). Tumours with pleural contact had a significantly larger SDtrans than tumours surrounded by lung tissue. Conclusions The interobserver delineation variation was very small in this systematic cross-sectional analysis, although significantly larger in the CC direction than in the transversal plane, stressing that anisotropic margins should be applied. This study is the first to make a systematic cross-sectional analysis of delineation variation for peripheral lung tumours referred for SBRT, establishing the evidence that interobserver variation is very small for these tumours. PMID:22919015
NASA Astrophysics Data System (ADS)
Nieves, Juan; Sobczyk, Joanna E.
2017-08-01
In a well-established many-body framework, successful in modeling a great variety of nuclear processes, we analyze the role of the spectral functions (SFs) accounting for the modifications of the dispersion relation of nucleons embedded in a nuclear medium. We concentrate in processes mostly governed by one-body mechanisms, and study possible approximations to evaluate the particle-hole propagator using SFs. We also investigate how to include together SFs and long-range RPA-correlation corrections in the evaluation of nuclear response functions, discussing the existing interplay between both type of nuclear effects. At low energy transfers (≤ 50 MeV), we compare our predictions for inclusive muon and radiative pion captures in nuclei, and charge-current (CC) neutrino-nucleus cross sections with experimental results. We also present an analysis of intermediate energy quasi-elastic neutrino scattering for various targets and both neutrino and antineutrino CC driven processes. In all cases, we pay special attention to estimate the uncertainties affecting the theoretical predictions. In particular, we show that errors on the σμ /σe ratio are much smaller than 5%, and also much smaller than the size of the SF+RPA nuclear corrections, which produce significant effects, not only in the individual cross sections, but also in their ratio for neutrino energies below 400 MeV. These latter nuclear corrections, beyond Pauli blocking, turn out to be thus essential to achieve a correct theoretical understanding of this ratio of cross sections of interest for appearance neutrino oscillation experiments. We also briefly compare our SF and RPA results to predictions obtained within other representative approaches.
Abdullah, Ayesha S; Jadoon, Milhammad Zahid; Akram, Mohammad; Awan, Zahid Hussain; Azam, Mohammad; Safdar, Mohammad; Nigar, Mohammad
2015-01-01
Uncorrected refractive errors are a leading cause of visual disability globally. This population-based study was done to estimate the prevalence of uncorrected refractive errors in adults aged 30 years and above of village Pawakah, Khyber Pakhtunkhwa (KPK), Pakistan. It was a cross-sectional survey in which 1000 individuals were included randomly. All the individuals were screened for uncorrected refractive errors and those whose visual acuity (VA) was found to be less than 6/6 were refracted. In whom refraction was found to be unsatisfactory (i.e., a best corrected visual acuity of <6/6) further examination was done to establish the cause for the subnormal vision. A total of 917 subjects participated in the survey (response rate 92%). The prevalence of uncorrected refractive errors was found to be 23.97% among males and 20% among females. The prevalence of visually disabling refractive errors was 6.89% in males and 5.71% in females. The prevalence was seen to increase with age, with maximum prevalence in 51-60 years age group. Hypermetropia (10.14%) was found to be the commonest refractive error followed by Myopia (6.00%) and Astigmatism (5.6%). The prevalence of Presbyopia was 57.5% (60.45% in males and 55.23% in females). Poor affordability was the commonest barrier to the use of spectacles, followed by unawareness. Cataract was the commonest reason for impaired vision after refractive correction. The prevalence of blindness was 1.96% (1.53% in males and 2.28% in females) in this community with cataract as the commonest cause. Despite being the most easily avoidable cause of subnormal vision uncorrected refractive errors still account for a major proportion of the burden of decreased vision in this area. Effective measures for the screening and affordable correction of uncorrected refractive errors need to be incorpora'ted into the health care delivery system.
de Oliveira, Paula Duarte; Menezes, Ana Maria Baptista; Bertoldi, Andréa Dâmaso; Wehrmeister, Fernando César; Macedo, Silvia Elaine Cardozo
2014-01-01
OBJECTIVE: To identify incorrect inhaler techniques employed by patients with respiratory diseases in southern Brazil and to profile the individuals who make such errors. METHODS: This was a population-based, cross-sectional study involving subjects ≥ 10 years of age using metered dose inhalers (MDIs) or dry powder inhalers (DPIs) in 1,722 households in the city of Pelotas, Brazil. RESULTS: We included 110 subjects, who collectively used 94 MDIs and 49 DPIs. The most common errors in the use of MDIs and DPIs were not exhaling prior to inhalation (66% and 47%, respectively), not performing a breath-hold after inhalation (29% and 25%), and not shaking the MDI prior to use (21%). Individuals ≥ 60 years of age more often made such errors. Among the demonstrations of the use of MDIs and DPIs, at least one error was made in 72% and 51%, respectively. Overall, there were errors made in all steps in 11% of the demonstrations, whereas there were no errors made in 13%.Among the individuals who made at least one error, the proportion of those with a low level of education was significantly greater than was that of those with a higher level of education, for MDIs (85% vs. 60%; p = 0.018) and for DPIs (81% vs. 35%; p = 0.010). CONCLUSIONS: In this sample, the most common errors in the use of inhalers were not exhaling prior to inhalation, not performing a breath-hold after inhalation, and not shaking the MDI prior to use. Special attention should be given to education regarding inhaler techniques for patients of lower socioeconomic status and with less formal education, as well as for those of advanced age, because those populations are at a greater risk of committing errors in their use of inhalers. PMID:25410839
Mobarakabadi, Sedigheh Sedigh; Ebrahimipour, Hosein; Najar, Ali Vafaie; Janghorban, Roksana; Azarkish, Fatemeh
2017-03-01
Patient's safety is one of the main objective in healthcare services; however medical errors are a prevalent potential occurrence for the patients in treatment systems. Medical errors lead to an increase in mortality rate of the patients and challenges such as prolonging of the inpatient period in the hospitals and increased cost. Controlling the medical errors is very important, because these errors besides being costly, threaten the patient's safety. To evaluate the attitudes of nurses and midwives toward the causes and rates of medical errors reporting. It was a cross-sectional observational study. The study population was 140 midwives and nurses employed in Mashhad Public Hospitals. The data collection was done through Goldstone 2001 revised questionnaire. SPSS 11.5 software was used for data analysis. To analyze data, descriptive and inferential analytic statistics were used. Standard deviation and relative frequency distribution, descriptive statistics were used for calculation of the mean and the results were adjusted as tables and charts. Chi-square test was used for the inferential analysis of the data. Most of midwives and nurses (39.4%) were in age range of 25 to 34 years and the lowest percentage (2.2%) were in age range of 55-59 years. The highest average of medical errors was related to employees with three-four years of work experience, while the lowest average was related to those with one-two years of work experience. The highest average of medical errors was during the evening shift, while the lowest were during the night shift. Three main causes of medical errors were considered: illegibile physician prescription orders, similarity of names in different drugs and nurse fatigueness. The most important causes for medical errors from the viewpoints of nurses and midwives are illegible physician's order, drug name similarity with other drugs, nurse's fatigueness and damaged label or packaging of the drug, respectively. Head nurse feedback, peer feedback, fear of punishment or job loss were considered as reasons for under reporting of medical errors. This research demonstrates the need for greater attention to be paid to the causes of medical errors.
Estimation of wave phase speed and nearshore bathymetry from video imagery
Stockdon, H.F.; Holman, R.A.
2000-01-01
A new remote sensing technique based on video image processing has been developed for the estimation of nearshore bathymetry. The shoreward propagation of waves is measured using pixel intensity time series collected at a cross-shore array of locations using remotely operated video cameras. The incident band is identified, and the cross-spectral matrix is calculated for this band. The cross-shore component of wavenumber is found as the gradient in phase of the first complex empirical orthogonal function of this matrix. Water depth is then inferred from linear wave theory's dispersion relationship. Full bathymetry maps may be measured by collecting data in a large array composed of both cross-shore and longshore lines. Data are collected hourly throughout the day, and a stable, daily estimate of bathymetry is calculated from the median of the hourly estimates. The technique was tested using 30 days of hourly data collected at the SandyDuck experiment in Duck, North Carolina, in October 1997. Errors calculated as the difference between estimated depth and ground truth data show a mean bias of -35 cm (rms error = 91 cm). Expressed as a fraction of the true water depth, the mean percent error was 13% (rms error = 34%). Excluding the region of known wave nonlinearities over the bar crest, the accuracy of the technique improved, and the mean (rms) error was -20 cm (75 cm). Additionally, under low-amplitude swells (wave height H ???1 m), the performance of the technique across the entire profile improved to 6% (29%) of the true water depth with a mean (rms) error of -12 cm (71 cm). Copyright 2000 by the American Geophysical Union.
NASA Astrophysics Data System (ADS)
Tambara, Lucas Antunes; Tonfat, Jorge; Santos, André; Kastensmidt, Fernanda Lima; Medina, Nilberto H.; Added, Nemitala; Aguiar, Vitor A. P.; Aguirre, Fernando; Silveira, Marcilei A. G.
2017-02-01
The increasing system complexity of FPGA-based hardware designs and shortening of time-to-market have motivated the adoption of new designing methodologies focused on addressing the current need for high-performance circuits. High-Level Synthesis (HLS) tools can generate Register Transfer Level (RTL) designs from high-level software programming languages. These tools have evolved significantly in recent years, providing optimized RTL designs, which can serve the needs of safety-critical applications that require both high performance and high reliability levels. However, a reliability evaluation of HLS-based designs under soft errors has not yet been presented. In this work, the trade-offs of different HLS-based designs in terms of reliability, resource utilization, and performance are investigated by analyzing their behavior under soft errors and comparing them to a standard processor-based implementation in an SRAM-based FPGA. Results obtained from fault injection campaigns and radiation experiments show that it is possible to increase the performance of a processor-based system up to 5,000 times by changing its architecture with a small impact in the cross section (increasing up to 8 times), and still increasing the Mean Workload Between Failures (MWBF) of the system.
Armeanu, Daniel; Vintilă, Georgeta; Gherghina, Ştefan Cristian; Drăgoi, Mihaela Cristina; Teodor, Cristian
2018-01-01
This study examines the Environmental Kuznets Curve hypothesis (EKC), considering the primary energy consumption among other country-specific variables, for a panel of the EU-28 countries during the period 1990–2014. By estimating pooled OLS regressions with Driscoll-Kraay standard errors in order to account for cross-sectional dependence, the results confirm the EKC hypothesis in the case of emissions of sulfur oxides and emissions of non-methane volatile organic compounds. In addition to pooled estimations, the output of fixed-effects regressions with Driscoll-Kraay standard errors support the EKC hypothesis for greenhouse gas emissions, greenhouse gas emissions intensity of energy consumption, emissions of nitrogen oxides, emissions of non-methane volatile organic compounds and emissions of ammonia. Additionally, the empirical findings from panel vector error correction model reveal a short-run unidirectional causality from GDP per capita growth to greenhouse gas emissions, as well as a bidirectional causal link between primary energy consumption and greenhouse gas emissions. Furthermore, since there occurred no causal link between economic growth and primary energy consumption, the neo-classical view was confirmed, namely the neutrality hypothesis. PMID:29742169
Armeanu, Daniel; Vintilă, Georgeta; Andrei, Jean Vasile; Gherghina, Ştefan Cristian; Drăgoi, Mihaela Cristina; Teodor, Cristian
2018-01-01
This study examines the Environmental Kuznets Curve hypothesis (EKC), considering the primary energy consumption among other country-specific variables, for a panel of the EU-28 countries during the period 1990-2014. By estimating pooled OLS regressions with Driscoll-Kraay standard errors in order to account for cross-sectional dependence, the results confirm the EKC hypothesis in the case of emissions of sulfur oxides and emissions of non-methane volatile organic compounds. In addition to pooled estimations, the output of fixed-effects regressions with Driscoll-Kraay standard errors support the EKC hypothesis for greenhouse gas emissions, greenhouse gas emissions intensity of energy consumption, emissions of nitrogen oxides, emissions of non-methane volatile organic compounds and emissions of ammonia. Additionally, the empirical findings from panel vector error correction model reveal a short-run unidirectional causality from GDP per capita growth to greenhouse gas emissions, as well as a bidirectional causal link between primary energy consumption and greenhouse gas emissions. Furthermore, since there occurred no causal link between economic growth and primary energy consumption, the neo-classical view was confirmed, namely the neutrality hypothesis.
Moylan, Elizabeth C; Kowalczuk, Maria K
2016-11-23
To assess why articles are retracted from BioMed Central journals, whether retraction notices adhered to the Committee on Publication Ethics (COPE) guidelines, and are becoming more frequent as a proportion of published articles. Retrospective cross-sectional analysis of 134 retractions from January 2000 to December 2015. 134 retraction notices were published during this timeframe. Although they account for 0.07% of all articles published (190 514 excluding supplements, corrections, retractions and commissioned content), the rate of retraction is rising. COPE guidelines on retraction were adhered to in that an explicit reason for each retraction was given. However, some notices did not document who retracted the article (eight articles, 6%) and others were unclear whether the underlying cause was honest error or misconduct (15 articles, 11%). The largest proportion of notices was issued by the authors (47 articles, 35%). The majority of retractions were due to some form of misconduct (102 articles, 76%), that is, compromised peer review (44 articles, 33%), plagiarism (22 articles, 16%) and data falsification/fabrication (10 articles, 7%). Honest error accounted for 17 retractions (13%) of which 10 articles (7%) were published in error. The median number of days from publication to retraction was 337.5 days. The most common reason to retract was compromised peer review. However, the majority of these cases date to March 2015 and appear to be the result of a systematic attempt to manipulate peer review across several publishers. Retractions due to plagiarism account for the second largest category and may be reduced by screening manuscripts before publication although this is not guaranteed. Retractions due to problems with the data may be reduced by appropriate data sharing and deposition before publication. Adopting a checklist (linked to COPE guidelines) and templates for various classes of retraction notices would increase transparency of retraction notices in future. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Gibson, Rachel; Eriksen, Rebeca; Lamb, Kathryn; McMeel, Yvonne; Vergnaud, Anne-Claire; Spear, Jeanette; Aresu, Maria; Chan, Queenie; Elliott, Paul; Frost, Gary
2017-01-01
Objectives Dietary intake is a key aspect of occupational health. To capture the characteristics of dietary behaviour that is affected by occupational environment that may affect disease risk, a collection of prospective multiday dietary records is required. The aims of this paper are to: (1) collect multiday dietary data in the Airwave Health Monitoring Study, (2) describe the dietary coding procedures applied and (3) investigate the plausibility of dietary reporting in this occupational cohort. Design A dietary coding protocol for this large-scale study was developed to minimise coding error rate. Participants (n 4412) who completed 7-day food records were included for cross-sectional analyses. Energy intake (EI) misreporting was estimated using the Goldberg method. Multivariate logistic regression models were applied to determine participant characteristics associated with EI misreporting. Setting British police force employees enrolled (2007–2012) into the Airwave Health Monitoring Study. Results The mean code error rate per food diary was 3.7% (SD 3.2%). The strongest predictors of EI under-reporting were body mass index (BMI) and physical activity. Compared with participants with BMI<25 kg/m2, those with BMI>30 kg/m2 had increased odds of being classified as under-reporting EI (men OR 5.20 95% CI 3.92 to 6.89; women OR 2.66 95% CI 1.85 to 3.83). Men and women in the highest physical activity category compared with the lowest were also more likely to be classified as under-reporting (men OR 3.33 95% CI 2.46 to 4.50; women OR 4.34 95% CI 2.91 to 6.55). Conclusions A reproducible dietary record coding procedure has been developed to minimise coding error in complex 7-day diet diaries. The prevalence of EI under-reporting is comparable with existing national UK cohorts and, in agreement with previous studies, classification of under-reporting was biased towards specific subgroups of participants. PMID:28377391
Alqubaisi, Mai; Tonna, Antonella; Strath, Alison; Stewart, Derek
2016-11-01
The aims of this study were to quantify the behavioural determinants of health professional reporting of medication errors in the United Arab Emirates (UAE) and to explore any differences between respondents. A cross-sectional survey of patient-facing doctors, nurses and pharmacists within three major hospitals of Abu Dhabi, the UAE. An online questionnaire was developed based on the Theoretical Domains Framework (TDF, a framework of behaviour change theories). Principal component analysis (PCA) was used to identify components and internal reliability determined. Ethical approval was obtained from a UK university and all hospital ethics committees. Two hundred and ninety-four responses were received. Questionnaire items clustered into six components of knowledge and skills, feedback and support, action and impact, motivation, effort and emotions. Respondents generally gave positive responses for knowledge and skills, feedback and support and action and impact components. Responses were more neutral for the motivation and effort components. In terms of emotions, the component with the most negative scores, there were significant differences in terms of years registered as health professional (those registered longest most positive, p = 0.002) and age (older most positive, p < 0.001) with no differences for gender and health profession. Emotional-related issues are the dominant barrier to reporting and are common to all professions. There is a need to develop, test and implement an intervention to impact health professionals' emotions. Such an intervention should focus on evidence-based behaviour change techniques of reducing negative emotions, focusing on emotional consequences and providing social support. • This research used the Theoretical Domains Framework to quantify the behavioural determinants of health professional reporting of medication errors. • Questionnaire items relating to emotions surrounding reporting generated the most negative responses with significant differences in terms of years registered as health professional (those registered longest most positive) and age (older most positive) with no differences for gender and health profession. • Interventions based on behaviour change techniques mapped to emotions should be prioritised for development.
The Chandra Source Catalog 2.0: Early Cross-matches
NASA Astrophysics Data System (ADS)
Rots, Arnold H.; Allen, Christopher E.; Anderson, Craig S.; Budynkiewicz, Jamie A.; Burke, Douglas; Chen, Judy C.; Civano, Francesca Maria; D'Abrusco, Raffaele; Doe, Stephen M.; Evans, Ian N.; Evans, Janet D.; Fabbiano, Giuseppina; Gibbs, Danny G., II; Glotfelty, Kenny J.; Graessle, Dale E.; Grier, John D.; Hain, Roger; Hall, Diane M.; Harbo, Peter N.; Houck, John C.; Lauer, Jennifer L.; Laurino, Omar; Lee, Nicholas P.; Martínez-Galarza, Rafael; McCollough, Michael L.; McDowell, Jonathan C.; Miller, Joseph; McLaughlin, Warren; Morgan, Douglas L.; Mossman, Amy E.; Nguyen, Dan T.; Nichols, Joy S.; Nowak, Michael A.; Paxson, Charles; Plummer, David A.; Primini, Francis Anthony; Siemiginowska, Aneta; Sundheim, Beth A.; Tibbetts, Michael; Van Stone, David W.; Zografou, Panagoula
2018-01-01
Cross-matching the Chandra Source Catalog (CSC) with other catalogs presents considerable challenges, since the Point Spread Function (PSF) of the Chandra X-ray Observatory varies significantly over the field of view. For the second release of the CSC (CSC2) we have been developing a cross-match tool that is based on the Bayesian algorithms by Budavari, Heinis, and Szalay (ApJ 679, 301 and 705, 739), making use of the error ellipses for the derived positions of the sources.However, calculating match probabilities only on the basis of error ellipses breaks down when the PSFs are significantly different. Not only can bonafide matches easily be missed, but the scene is also muddied by ambiguous multiple matches. These are issues that are not commonly addressed in cross-match tools. We have applied a satisfactory modification to the algorithm that, although not perfect, ameliorates the problems for the vast majority of such cases.We will present some early cross-matches of the CSC2 catalog with obvious candidate catalogs and report on the determination of the absolute astrometric error of the CSC2 based on such cross-matches.This work has been supported by NASA under contract NAS 8-03060 to the Smithsonian Astrophysical Observatory for operation of the Chandra X-ray Center.
Predictors and Outcomes of Burnout in Primary Care Physicians.
Rabatin, Joseph; Williams, Eric; Baier Manwell, Linda; Schwartz, Mark D; Brown, Roger L; Linzer, Mark
2016-01-01
To assess relationships between primary care work conditions, physician burnout, quality of care, and medical errors. Cross-sectional and longitudinal analyses of data from the MEMO (Minimizing Error, Maximizing Outcome) Study. Two surveys of 422 family physicians and general internists, administered 1 year apart, queried physician job satisfaction, stress and burnout, organizational culture, and intent to leave within 2 years. A chart audit of 1795 of their adult patients with diabetes and/or hypertension assessed care quality and medical errors. Women physicians were almost twice as likely as men to report burnout (36% vs 19%, P < .001). Burned out clinicians reported less satisfaction (P < .001), more job stress (P < .001), more time pressure during visits (P < .01), more chaotic work conditions (P < .001), and less work control (P < .001). Their workplaces were less likely to emphasize work-life balance (P < .001) and they noted more intent to leave the practice (56% vs 21%, P < .001). There were no consistent relationships between burnout, care quality, and medical errors. Burnout is highly associated with adverse work conditions and a greater intention to leave the practice, but not with adverse patient outcomes. Care quality thus appears to be preserved at great personal cost to primary care physicians. Efforts focused on workplace redesign and physician self-care are warranted to sustain the primary care workforce. © The Author(s) 2015.
Systematic review of the evidence for Trails B cut-off scores in assessing fitness-to-drive
Roy, Mononita; Molnar, Frank
2013-01-01
Background Fitness-to-drive guidelines recommend employing the Trail Making B Test (a.k.a. Trails B), but do not provide guidance regarding cut-off scores. There is ongoing debate regarding the optimal cut-off score on the Trails B test. The objective of this study was to address this controversy by systematically reviewing the evidence for specific Trails B cut-off scores (e.g., cut-offs in both time to completion and number of errors) with respect to fitness-to-drive. Methods Systematic review of all prospective cohort, retrospective cohort, case-control, correlation, and cross-sectional studies reporting the ability of the Trails B to predict driving safety that were published in English-language, peer-reviewed journals. Results Forty-seven articles were reviewed. None of the articles justified sample sizes via formal calculations. Cut-off scores reported based on research include: 90 seconds, 133 seconds, 147 seconds, 180 seconds, and < 3 errors. Conclusions There is support for the previously published Trails B cut-offs of 3 minutes or 3 errors (the ‘3 or 3 rule’). Major methodological limitations of this body of research were uncovered including (1) lack of justification of sample size leaving studies open to Type II error (i.e., false negative findings), and (2) excessive focus on associations rather than clinically useful cut-off scores. PMID:23983828
Relationship between lenticular power and refractive error in children with hyperopia
Tomomatsu, Takeshi; Kono, Shinjiro; Arimura, Shogo; Tomomatsu, Yoko; Matsumura, Takehiro; Takihara, Yuji; Inatani, Masaru; Takamura, Yoshihiro
2013-01-01
Objectives To evaluate the contribution of axial length, and lenticular and corneal power to the spherical equivalent refractive error in children with hyperopia between 3 and 13 years of age, using noncontact optical biometry. Methods There were 62 children between 3 and 13 years of age with hyperopia (+2 diopters [D] or more) who underwent automated refraction measurement with cycloplegia, to measure spherical equivalent refractive error and corneal power. Axial length was measured using an optic biometer that does not require contact with the cornea. The refractive power of the lens was calculated using the Sanders-Retzlaff-Kraff formula. Single regression analysis was used to evaluate the correlation among the optical parameters. Results There was a significant positive correlation between age and axial length (P = 0.0014); however, the degree of hyperopia did not decrease with aging (P = 0.59). There was a significant negative correlation between age and the refractive power of the lens (P = 0.0001) but not that of the cornea (P = 0.43). A significant negative correlation was observed between the degree of hyperopia and lenticular power (P < 0.0001). Conclusion Although this study is small scale and cross sectional, the analysis, using noncontact biometry, showed that lenticular power was negatively correlated with refractive error and age, indicating that lower lens power may contribute to the degree of hyperopia. PMID:23576859
Predictors and Outcomes of Burnout in Primary Care Physicians
Rabatin, Joseph; Williams, Eric; Baier Manwell, Linda; Schwartz, Mark D.; Brown, Roger L.; Linzer, Mark
2015-01-01
Objective: To assess relationships between primary care work conditions, physician burnout, quality of care, and medical errors. Methods: Cross-sectional and longitudinal analyses of data from the MEMO (Minimizing Error, Maximizing Outcome) Study. Two surveys of 422 family physicians and general internists, administered 1 year apart, queried physician job satisfaction, stress and burnout, organizational culture, and intent to leave within 2 years. A chart audit of 1795 of their adult patients with diabetes and/or hypertension assessed care quality and medical errors. Key Results: Women physicians were almost twice as likely as men to report burnout (36% vs 19%, P < .001). Burned out clinicians reported less satisfaction (P < .001), more job stress (P < .001), more time pressure during visits (P < .01), more chaotic work conditions (P < .001), and less work control (P < .001). Their workplaces were less likely to emphasize work-life balance (P < .001) and they noted more intent to leave the practice (56% vs 21%, P < .001). There were no consistent relationships between burnout, care quality, and medical errors. Conclusions: Burnout is highly associated with adverse work conditions and a greater intention to leave the practice, but not with adverse patient outcomes. Care quality thus appears to be preserved at great personal cost to primary care physicians. Efforts focused on workplace redesign and physician self-care are warranted to sustain the primary care workforce. PMID:26416697
Campmans, Zizi; van Rhijn, Arianne; Dull, René M; Santen-Reestman, Jacqueline; Taxis, Katja; Borgsteede, Sander D
2018-01-01
Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. 'Alert fatigue' was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue.
The Trojan Horse method for nuclear astrophysics: Recent results on resonance reactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cognata, M. La; Pizzone, R. G.; Spitaleri, C.
Nuclear astrophysics aims to measure nuclear-reaction cross sections of astrophysical interest to be included into models to study stellar evolution and nucleosynthesis. Low energies, < 1 MeV or even < 10 keV, are requested for this is the window where these processes are more effective. Two effects have prevented to achieve a satisfactory knowledge of the relevant nuclear processes, namely, the Coulomb barrier exponentially suppressing the cross section and the presence of atomic electrons. These difficulties have triggered theoretical and experimental investigations to extend our knowledge down to astrophysical energies. For instance, indirect techniques such as the Trojan Horse Methodmore » have been devised yielding new cutting-edge results. In particular, I will focus on the application of this indirect method to resonance reactions. Resonances might dramatically enhance the astrophysical S(E)-factor so, when they occur right at astrophysical energies, their measurement is crucial to pin down the astrophysical scenario. Unknown or unpredicted resonances might introduce large systematic errors in nucleosynthesis models. These considerations apply to low-energy resonances and to sub-threshold resonances as well, as they may produce sizable modifications of the S-factor due to, for instance, destructive interference with another resonance.« less
Photoproduction of D ∗± mesons in electron-proton collisions at HERA
NASA Astrophysics Data System (ADS)
Aid, S.; Andreev, V.; Andrieu, B.; Appuhn, R.-D.; Arpagaus, M.; Babaev, A.; Bähr, J.; Bán, J.; Ban, Y.; Baranov, P.; Barrelet, E.; Barschke, R.; Bartel, W.; Barth, M.; Bassler, U.; Beck, H. P.; Behrend, H.-J.; Belousov, A.; Berger, Ch.; Bernardi, G.; Bernet, R.; Bertrand-Coremans, G.; Besançon, M.; Beyer, R.; Biddulph, P.; Bispham, P.; Bizot, J. C.; Blobel, V.; Borras, K.; Botterweck, F.; Boudry, V.; Braemer, A.; Braunschweig, W.; Brisson, V.; Bruncko, D.; Brune, C.; Buchholz, R.; Büngener, L.; Bürger, J.; Büsser, F. W.; Buniatian, A.; Burke, S.; Burton, M. J.; Buschhorn, G.; Campbell, A. J.; Carli, T.; Charlet, M.; Clarke, D.; Clegg, A. B.; Clerbaux, B.; Cocks, S.; Contreras, J. G.; Cormack, C.; Coughlan, J. A.; Courau, A.; Cousinou, M.-C.; Cozzika, G.; Criegee, L.; Cussans, D. G.; Cvach, J.; Dagoret, S.; Dainton, J. B.; Dau, W. D.; Daum, K.; David, M.; Davis, C. L.; Delcourt, B.; De Roeck, A.; De Wolf, E. A.; Dirkmann, M.; Dixon, P.; Di Nezza, P.; Dlugosz, W.; Dollfus, C.; Dowell, J. D.; Dreis, H. B.; Droutskoi, A.; Düllmann, D.; Dünger, O.; Duhm, H.; Ebert, J.; Ebert, T. R.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eichler, R.; Eisele, F.; Eisenhandler, E.; Ellison, R. J.; Elsen, E.; Erdmann, M.; Erdmann, W.; Evrard, E.; Fahr, A. B.; Favart, L.; Fedotov, A.; Feeken, D.; Felst, R.; Feltesse, J.; Ferencei, J.; Ferrarotto, F.; Flamm, K.; Fleischer, M.; Flieser, M.; Flügge, G.; Fomenko, A.; Fominykh, B.; Formánek, J.; Foster, J. M.; Franke, G.; Fretwurst, E.; Gabathuler, E.; Gabathuler, K.; Gaede, F.; Garvey, J.; Gayler, J.; Gebauer, M.; Gellrich, A.; Genzel, H.; Gerhards, R.; Glazov, A.; Goerlach, U.; Goerlich, L.; Gogitidze, N.; Goldberg, M.; Goldner, D.; Golec-Biernat, K.; Gonzalez-Pineiro, B.; Gorelov, I.; Grab, C.; Grässler, H.; Grässler, R.; Greenshaw, T.; Griffiths, R. K.; Grindhammer, G.; Gruber, A.; Gruber, C.; Haack, J.; Hadig, T.; Haidt, D.; Hajduk, L.; Hampel, M.; Haynes, W. J.; Heinzelmann, G.; Henderson, R. C. W.; Henschel, H.; Herynek, I.; Hess, M. F.; Hildesheim, W.; Hiller, K. H.; Hilton, C. D.; Hladký, J.; Hoeger, K. C.; Höppner, M.; Hoffmann, D.; Holtom, T.; Horisberger, R.; Hudgson, V. L.; Hütte, M.; Hufnagel, H.; Ibbotson, M.; Itterbeck, H.; Jacholkowska, A.; Jacobsson, C.; Jaffre, M.; Janoth, J.; Jansen, T.; Jönsson, L.; Johannsen, K.; Johnson, D. P.; Johnson, L.; Jung, H.; Kalmus, P. I. P.; Kander, M.; Kant, D.; Kaschowitz, R.; Kathage, U.; Katzy, J.; Kaufmann, H. H.; Kaufmann, O.; Kazarian, S.; Kenyon, I. R.; Kermiche, S.; Keuker, C.; Kiesling, C.; Klein, M.; Kleinwort, C.; Knies, G.; Köhler, T.; Köhne, J. H.; Kolanoski, H.; Kole, F.; Kolya, S. D.; Korbel, V.; Korn, M.; Kostka, P.; Kotelnikov, S. K.; Krämerkämper, T.; Krasny, M. W.; Krehbiel, H.; Krücker, D.; Krüger, U.; Krüner-Marquis, U.; Küster, H.; Kuhlen, M.; Kurča, T.; Kurzhöfer, J.; Lacour, D.; Laforge, B.; Lander, R.; Landon, M. P. J.; Lange, W.; Langenegger, U.; Laporte, J.-F.; Lebedev, A.; Lehner, F.; Leverenz, C.; Levonian, S.; Ley, Ch.; Lindström, G.; Lindstroem, M.; Link, J.; Linsel, F.; Lipinski, J.; List, B.; Lobo, G.; Lohmander, H.; Lomas, J. W.; Lopez, G. C.; Lubimov, V.; Lüke, D.; Magnussen, N.; Malinovski, E.; Mani, S.; Maraček, R.; Marage, P.; Marks, J.; Marshall, R.; Martens, J.; Martin, G.; Martin, R.; Martyn, H.-U.; Martyniak, J.; Mavroidis, T.; Maxfield, S. J.; McMahon, S. J.; Mehta, A.; Meier, K.; Merz, T.; Meyer, A.; Meyer, A.; Meyer, H.; Meyer, J.; Meyer, P.-O.; Migliori, A.; Mikocki, S.; Milstead, D.; Moeck, J.; Moreau, F.; Morris, J. V.; Mroczko, E.; Müller, D.; Müller, G.; Müller, K.; Murín, P.; Nagovizin, V.; Nahnhauer, R.; Naroska, B.; Naumann, Th.; Newman, P. R.; Newton, D.; Neyret, D.; Nguyen, H. K.; Nicholls, T. C.; Niebergall, F.; Niebuhr, C.; Niedzballa, Ch.; Niggli, H.; Nisius, R.; Nowak, G.; Noyes, G. W.; Nyberg Werther, M.; Oakden, M.; Oberlack, H.; Obrock, U.; Olsson, J. E.; Ozerov, D.; Palmen, P.; Panaro, E.; Panitch, A.; Pascaud, C.; Patel, G. D.; Pawletta, H.; Peppel, E.; Perez, E.; Phillips, J. P.; Pieuchot, A.; Pitzl, D.; Pope, G.; Prell, S.; Prosi, R.; Rabbertz, K.; Rädel, G.; Raupach, F.; Reimer, P.; Reinshagen, S.; Rick, H.; Riech, V.; Riedlberger, J.; Riepenhausen, F.; Riess, S.; Rizvi, E.; Robertson, S. M.; Robmann, P.; Roloff, H. E.; Roosen, R.; Rosenbauer, K.; Rostovtsev, A.; Rouse, F.; Royon, C.; Rüter, K.; Rusakov, S.; Rybicki, K.; Sahlmann, N.; Sankey, D. P. C.; Schacht, P.; Schiek, S.; Schleif, S.; Schleper, P.; von Schlippe, W.; Schmidt, D.; Schmidt, G.; Schöning, A.; Schröder, V.; Schuhmann, E.; Schwab, B.; Sefkow, F.; Seidel, M.; Sell, R.; Semenov, A.; Shekelyan, V.; Sheviakov, I.; Shtarkov, L. N.; Siegmon, G.; Siewert, U.; Sirois, Y.; Skillicorn, I. O.; Smirnov, P.; Smith, J. R.; Solochenko, V.; Soloviev, Y.; Specka, A.; Spiekermann, J.; Spielman, S.; Spitzer, H.; Squinabol, F.; Starosta, R.; Steenbock, M.; Steffen, P.; Steinberg, R.; Steiner, H.; Stella, B.; Stellberger, A.; Stier, J.; Stiewe, J.; Stöβlein, U.; Stolze, K.; Straumann, U.; Struczinski, W.; Sutton, J. P.; Tapprogge, S.; Taševský, M.; Tchernyshov, V.; Tchetchelnitski, S.; Theissen, J.; Thiebaux, C.; Thompson, G.; Truöl, P.; Turnau, J.; Tutas, J.; Uelkes, P.; Usik, A.; Valkár, S.; Valkárová, A.; Vallée, C.; Vandenplas, D.; Van Esch, P.; Van Mechelen, P.; Vazdik, Y.; Verrecchia, P.; Villet, G.; Wacker, K.; Wagener, A.; Wagener, M.; Walther, A.; Waugh, B.; Weber, G.; Weber, M.; Wegener, D.; Wegner, A.; Wengler, T.; Werner, M.; West, L. R.; Wilksen, T.; Willard, S.; Winde, M.; Winter, G.-G.; Wittek, C.; Wünsch, E.; Žáček, J.; Zarbock, D.; Zhang, Z.; Zhokin, A.; Zomer, F.; Zsembery, J.; Zuber, K.; zurNedden, M.; H1 Collaboration
1996-02-01
At the electron-proton collider HERA the inclusive D ∗± meson photoproduction cross section has been measured with the H1 detector in two different, but partly overlapping, kinematical regions. For the first, where < Wγp> ≈ 200 GeV and Q2 < 0.01 GeV 2, the result is σ(γp → c overlinecX) = (13.2 ± 2.2 -1.7 -4.8+2.1 +9.9) μ b. The second measurement for Q2 < 4 GeV 2 yields σ(γp → c overlinecX) = (9.3 ± 2.1 -1.8 -3.2+1.9 +6.9) μ b at
Al-Zaben, Faten N; Sehlo, Mohammad G; Koenig, Harold G
2015-10-01
To examine relationship between the quality of marital relationship and anxiety among women with breast cancer (BC) in the Kingdom of Saudi Arabia (KSA). This cross-sectional study recruited a consecutive series of 49 married women with BC seen in the Al-Amoudi Breast Cancer Center of Excellence at King Abdulaziz University, Jeddah, KSA in early 2013. Participants completed the Hospital Anxiety and Depression Scale, Spouse Perception Scale, and Quality of Marriage Index forms, and answered questions on demographic and cancer characteristics. Anxiety symptoms indicating "possible" anxiety disorder were present in 10.4% and "probable" anxiety disorder in 14.6% (25% total). No significant relationship was found between the quality of marital relationship and anxiety symptoms (B=-0.04, standard error=0.05, t=-0.81, p=0.42). Anxiety was primarily driven by low education, poor socioeconomic status, and young age. Anxiety symptoms are prevalent among married women with BC seen in a university-based clinic in the KSA. Further research is needed to determine whether a diagnosis of BC adversely affects marital relationship, and whether this is the cause for anxiety in these women.
Lu, Wen-Cheng
2017-11-01
This article aims to investigate the relationship among renewable energy consumption, carbon dioxide (CO 2 ) emissions, and GDP using panel data for 24 Asian countries between 1990 and 2012. Panel cross-sectional dependence tests and unit root test, which considers cross-sectional dependence across countries, are used to ensure that the empirical results are correct. Using the panel cointegration model, the vector error correction model, and the Granger causality test, this paper finds that a long-run equilibrium exists among renewable energy consumption, carbon emission, and GDP. CO 2 emissions have a positive effect on renewable energy consumption in the Philippines, Pakistan, China, Iraq, Yemen, and Saudi Arabia. A 1% increase in GDP will increase renewable energy by 0.64%. Renewable energy is significantly determined by GDP in India, Sri Lanka, the Philippines, Thailand, Turkey, Malaysia, Jordan, United Arab Emirates, Saudi Arabia, and Mongolia. A unidirectional causality runs from GDP to CO 2 emissions, and two bidirectional causal relationships were found between CO 2 emissions and renewable energy consumption and between renewable energy consumption and GDP. The findings can assist governments in curbing pollution from air pollutants, execute energy conservation policy, and reduce unnecessary wastage of energy.
Dynamic analysis of I cross beam section dissimilar plate joined by TIG welding
NASA Astrophysics Data System (ADS)
Sani, M. S. M.; Nazri, N. A.; Rani, M. N. Abdul; Yunus, M. A.
2018-04-01
In this paper, finite element (FE) joint modelling technique for prediction of dynamic properties of sheet metal jointed by tungsten inert gas (TTG) will be presented. I cross section dissimilar flat plate with different series of aluminium alloy; AA7075 and AA6061 joined by TTG are used. In order to find the most optimum set of TTG welding dissimilar plate, the finite element model with three types of joint modelling were engaged in this study; bar element (CBAR), beam element and spot weld element connector (CWELD). Experimental modal analysis (EMA) was carried out by impact hammer excitation on the dissimilar plates that welding by TTG method. Modal properties of FE model with joints were compared and validated with model testing. CWELD element was chosen to represent weld model for TTG joints due to its accurate prediction of mode shapes and contains an updating parameter for weld modelling compare to other weld modelling. Model updating was performed to improve correlation between EMA and FEA and before proceeds to updating, sensitivity analysis was done to select the most sensitive updating parameter. After perform model updating, average percentage of error of the natural frequencies for CWELD model is improved significantly.
Sugary beverage intake and preclinical Alzheimer's disease in the community.
Pase, Matthew P; Himali, Jayandra J; Jacques, Paul F; DeCarli, Charles; Satizabal, Claudia L; Aparicio, Hugo; Vasan, Ramachandran S; Beiser, Alexa S; Seshadri, Sudha
2017-09-01
Excess sugar consumption has been linked with Alzheimer's disease (AD) pathology in animal models. We examined the cross-sectional association of sugary beverage consumption with neuropsychological (N = 4276) and magnetic resonance imaging (N = 3846) markers of preclinical Alzheimer's disease and vascular brain injury (VBI) in the community-based Framingham Heart Study. Intake of sugary beverages was estimated using a food frequency questionnaire. Relative to consuming less than one sugary beverage per day, higher intake of sugary beverages was associated with lower total brain volume (1-2/day, β ± standard error [SE] = -0.55 ± 0.14 mean percent difference, P = .0002; >2/day, β ± SE = -0.68 ± 0.18, P < .0001), and poorer performance on tests of episodic memory (all P < .01). Daily fruit juice intake was associated with lower total brain volume, hippocampal volume, and poorer episodic memory (all P < .05). Sugary beverage intake was not associated with VBI in a consistent manner across outcomes. Higher intake of sugary beverages was associated cross-sectionally with markers of preclinical AD. Copyright © 2017 the Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
Research into Influence of Gaussian Beam on Terahertz Radar Cross Section of a Semicircular Boss
NASA Astrophysics Data System (ADS)
Li, Hui-Yu; Li, Qi; She, Jian-Yu; Zhao, Yong-Peng; Chen, De-Ying; Wang, Qi
2013-08-01
In radar cross section (RCS) calculation of a rough surface, the model can be simplified into the scattering of geometrically idealized bosses on a surface. Thus the problem of the RCS calculation of a rough surface is changed to the RCS calculation of the semicircular boss. The RCS measurement of scale model can help save time and money. The utilization of terahertz in RCS is attractive because of its special properties: the wavelength of the terahertz wave can help limit the size of the model in a suitable range in the measurement of the scale model and get more detailed data in the measurement of the real object. However, usually the incident beam of a terahertz source is a Gaussian beam; in the theoretical RCS estimation, usually a plane wave is assumed as the incident beam for sake of simplicity which may lead to an error between the measurement and calculation results. In this paper, the method of images is used to calculate the RCS of a semicircular boss at 2.52 THz and the results are compared to the one calculated when the incident beam is a plane wave.
Power Enhancement in High Dimensional Cross-Sectional Tests
Fan, Jianqing; Liao, Yuan; Yao, Jiawei
2016-01-01
We propose a novel technique to boost the power of testing a high-dimensional vector H : θ = 0 against sparse alternatives where the null hypothesis is violated only by a couple of components. Existing tests based on quadratic forms such as the Wald statistic often suffer from low powers due to the accumulation of errors in estimating high-dimensional parameters. More powerful tests for sparse alternatives such as thresholding and extreme-value tests, on the other hand, require either stringent conditions or bootstrap to derive the null distribution and often suffer from size distortions due to the slow convergence. Based on a screening technique, we introduce a “power enhancement component”, which is zero under the null hypothesis with high probability, but diverges quickly under sparse alternatives. The proposed test statistic combines the power enhancement component with an asymptotically pivotal statistic, and strengthens the power under sparse alternatives. The null distribution does not require stringent regularity conditions, and is completely determined by that of the pivotal statistic. As specific applications, the proposed methods are applied to testing the factor pricing models and validating the cross-sectional independence in panel data models. PMID:26778846
A laboratory study of the lambda 2145 A auroral mystery feature
NASA Technical Reports Server (NTRS)
Erdman, P. W.; Espy, P. J.; Zipf, E. C.
1980-01-01
The prominent emission feature near 2145 A in the ultraviolet spectrum of an aurora has been tentatively identified by Dick (1978) as the doublet lines, 2139.68 A and 2143.55 A, emitted by metastable N+(5S) ions, and dissociative excitation of N2 by electron impact with a cross section greater than or equal to 2 x 10 to the -18th sq cm has been proposed as the source of this species. A detailed laboratory study of dissociative excitation is described that suggests two alternative viewpoints of this process: (1) If the calculated radiative lifetime for the N+(5S) state (4.4 microsec) is correct, then the N+(5S) dissociative excitation cross section is less than 3 x 10 to the -21st sq cm. Thus, a new N+(5S) source mechanism would have to be found in order to account for the auroral data. (2) If dissociative excitation does form N+(5S) ions efficiently, then the laboratory and field observations imply a radiative lifetime for this state of more than 10 msec, thus suggesting that there are major errors in the lifetime computation.
NASA Astrophysics Data System (ADS)
Martorana, N. S.; Cardella, G.; Lanza, E. G.; Acosta, L.; Andrés, M. V.; Auditore, L.; Catara, F.; De Filippo, E.; De Luca, S.; Dell'Aquila, D.; Gnoffo, B.; Lanzalone, G.; Lombardo, I.; Maiolino, C.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Quattrocchi, L.; Rizzo, F.; Russotto, P.; Santonocito, D.; Trifirò, A.; Trimarchi, M.; Vigilante, M.; Vitturi, A.
2018-07-01
The excitation of the Pygmy Dipole Resonance (PDR) in the 68Ni nucleus, above the neutron emission threshold, via an isoscalar probe has been observed for the first time. The excitation has been produced in reactions where a 68Ni beam, obtained by the fragmentation of a 70Zn primary beam at INFN-LNS, impinged on a 12C target. The γ-ray decay was detected using the CsI(Tl) detectors of the CHIMERA multidetector sphere. The 68Ni isotope as well as other heavy ion fragments were detected using the FARCOS array. The population of the PDR was evidenced by comparing the detected γ-ray energy spectra with statistical code calculations. The isotopic resolution of the detection system allows also to directly compare neutron decay channels with the 68Ni channel, better evidencing the PDR decay response function. This comparison allows also the extraction of the PDR cross section and the relative γ-ray angular distribution. The measured γ-ray angular distribution confirms the E1 character of the transition. The γ decay cross section for the excitation of the PDR was measured to be 0.32 mb with a 18% of statistical error.
A Two-Step Approach to Uncertainty Quantification of Core Simulators
Yankov, Artem; Collins, Benjamin; Klein, Markus; ...
2012-01-01
For the multiple sources of error introduced into the standard computational regime for simulating reactor cores, rigorous uncertainty analysis methods are available primarily to quantify the effects of cross section uncertainties. Two methods for propagating cross section uncertainties through core simulators are the XSUSA statistical approach and the “two-step” method. The XSUSA approach, which is based on the SUSA code package, is fundamentally a stochastic sampling method. Alternatively, the two-step method utilizes generalized perturbation theory in the first step and stochastic sampling in the second step. The consistency of these two methods in quantifying uncertainties in the multiplication factor andmore » in the core power distribution was examined in the framework of phase I-3 of the OECD Uncertainty Analysis in Modeling benchmark. With the Three Mile Island Unit 1 core as a base model for analysis, the XSUSA and two-step methods were applied with certain limitations, and the results were compared to those produced by other stochastic sampling-based codes. Based on the uncertainty analysis results, conclusions were drawn as to the method that is currently more viable for computing uncertainties in burnup and transient calculations.« less
NASA Astrophysics Data System (ADS)
Pueyo, E. L.; Izquierdo-Llavall, E.; Ayala, C.; Oliva-Urcia, B.; Rubio, F. M.; Rodríguez-Pintó, A.; Casas, A. M.; García Crespo, J.
2015-12-01
The lack of subsurface information in the Linking Zone (between the Iberian and the Catalan Coastal Ranges) where no seismic sections and few boreholes are available, together with the need to perform an evaluation of a potential CO2 reservoir, have motivated us to carry out a combined structural and geophysical study. The reservoir is located in the Bunt/Muschelkalk facies (Triassic in age) just underneath the Keuper evaporites (regional detachment). The expected density contrast between cover/basement/detachment rocks represent a suitable setting to apply gravity modeling. Therefore, we designed the location of eight serial and radial cross sections over 1.50000 available geological maps, we also include bedding data (field work) and thickness and depth information from wells and previous stratigraphic profiles. Besides, gravity data were acquired along the sections to build up 2.5D models and thus, to constrain the geometry of the basement and the thickness of the sedimentary cover. Density values used in the modelling come from a database with 1470 sites (compiled and acquired). Initially we build the balanced sections using the available geological information and applying standard geometric techniques. Regional knowledge and previous sections were also taken into account. Then, we took these sections into Oasis Montaj to fit the real and expected gravimetric signal. In this work we present the comparison of the location of certain horizons before and after that feedback. In some cases, mislocation of some horizons may reach up to 0.4 km, which represents up to 50% of the expected depth. After fitting the gravity data with balanced cross-sections we carried out a stochastic inversion that allowed reducing the uncertainty to a maximum of 0.15 km, i. e. c. 20% . Further error analysis may be focused on the double-checking with seismic section information from the industry, if and when available. Attached figure displays an example of one of the performed sections. There, extrapolation of subsurface structures under the Ebro foreland basin based on lateral information cannot be supported by the measured gravimetric signal. The mislocations of the basement top in A and B zones reach -0.4 and + 0.8 km respectively, with critical implications for any potential CO2 storage.
NASA Astrophysics Data System (ADS)
Thalman, Ryan; Zarzana, Kyle J.; Tolbert, Margaret A.; Volkamer, Rainer
2017-03-01
Tables 1 and 2 of the published material [1] contain a series of typographical errors. In Table 1 the exponent of the B term for N2 was corrected to 1012 and ν for the two N2 cases should be ν2 for the King correction factor. In Table 2 the units are (cm2×1027), the N2 calculation at 660.0 nm is 2.21×10-27 cm2 and the O2 calculation at 532.2 nm is 4.66×10-27 cm2.
Indications for a High-Rigidity Break in the Cosmic-Ray Diffusion Coefficient
NASA Astrophysics Data System (ADS)
Génolini, Yoann; Serpico, Pasquale D.; Boudaud, Mathieu; Caroff, Sami; Poulin, Vivian; Derome, Laurent; Lavalle, Julien; Maurin, David; Poireau, Vincent; Rosier, Sylvie; Salati, Pierre; Vecchi, Manuela
2017-12-01
Using cosmic-ray boron to carbon ratio (B/C) data recently released by the Ams-02 experiment, we find indications (decisive evidence, in Bayesian terms) in favor of a diffusive propagation origin for the broken power-law spectra found in protons (p ) and helium nuclei (He). The result is robust with respect to currently estimated uncertainties in the cross sections, and in the presence of a small component of primary boron, expected because of spallation at the acceleration site. Reduced errors at high energy as well as further cosmic ray nuclei data (as absolute spectra of C, N, O, Li, Be) may definitively confirm this scenario.
Determination of fiber volume in graphite/epoxy materials using computer image analysis
NASA Technical Reports Server (NTRS)
Viens, Michael J.
1990-01-01
The fiber volume of graphite/epoxy specimens was determined by analyzing optical images of cross sectioned specimens using image analysis software. Test specimens were mounted and polished using standard metallographic techniques and examined at 1000 times magnification. Fiber volume determined using the optical imaging agreed well with values determined using the standard acid digestion technique. The results were found to agree within 5 percent over a fiber volume range of 45 to 70 percent. The error observed is believed to arise from fiber volume variations within the graphite/epoxy panels themselves. The determination of ply orientation using image analysis techniques is also addressed.
Watson, Roger
2015-04-01
This article describes the basic tenets of quantitative research. The concepts of dependent and independent variables are addressed and the concept of measurement and its associated issues, such as error, reliability and validity, are explored. Experiments and surveys – the principal research designs in quantitative research – are described and key features explained. The importance of the double-blind randomised controlled trial is emphasised, alongside the importance of longitudinal surveys, as opposed to cross-sectional surveys. Essential features of data storage are covered, with an emphasis on safe, anonymous storage. Finally, the article explores the analysis of quantitative data, considering what may be analysed and the main uses of statistics in analysis.
[Cognitive dysfunction in patients with subclinical hypothyroidism].
Fernandes, Robertta Soares Miranda; Alvarenga, Nathália Bueno; Silva, Tamara Inácio da; Rocha, Felipe Filardi da
2011-04-01
Evaluate neuropsychological changes in patients with subclinical hypothyroidism (SH). Cross-sectional study comparing the results of the neuropsychological evaluation of 89 SH patients and 178 individuals without thyroid disease. The participants underwent the following neuropsychological assessment: Conner's Continuous Performance Test (CPT-II), Iowa Gambling Task, Stroop Test, Wisconsin Card Sorting Test (WCST), Verbal Fluency Test (semantic and phonologic categories) and Rey Auditory Verbal Learning Test. Among the neuropsychological tests, patients showed worse performance only in cognitive flexibility (WCST) and the ability to maintain sustained attention (omission errors on the CPT-II). These losses can cause detriments in the daily lives of patients, constituting potential treatment indications.
Comparison of Procedures for Dual and Triple Closely Spaced Parallel Runways
NASA Technical Reports Server (NTRS)
Verma, Savita; Ballinger, Deborah; Subramanian Shobana; Kozon, Thomas
2012-01-01
A human-in-the-loop high fidelity flight simulation experiment was conducted, which investigated and compared breakout procedures for Very Closely Spaced Parallel Approaches (VCSPA) with two and three runways. To understand the feasibility, usability and human factors of two and three runway VCSPA, data were collected and analyzed on the dependent variables of breakout cross track error and pilot workload. Independent variables included number of runways, cause of breakout and location of breakout. Results indicated larger cross track error and higher workload using three runways as compared to 2-runway operations. Significant interaction effects involving breakout cause and breakout location were also observed. Across all conditions, cross track error values showed high levels of breakout trajectory accuracy and pilot workload remained manageable. Results suggest possible avenues of future adaptation for adopting these procedures (e.g., pilot training), while also showing potential promise of the concept.
The effect of wind tunnel wall interference on the performance of a fan-in-wing VTOL model
NASA Technical Reports Server (NTRS)
Heyson, H. H.
1974-01-01
A fan-in-wing model with a 1.07-meter span was tested in seven different test sections with cross-sectional areas ranging from 2.2 sq meters to 265 sq meters. The data from the different test sections are compared both with and without correction for wall interference. The results demonstrate that extreme care must be used in interpreting uncorrected VTOL data since the wall interference may be so large as to invalidate even trends in the data. The wall interference is particularly large at the tail, a result which is in agreement with recently published comparisons of flight and large scale wind tunnel data for a propeller-driven deflected-slipstream configuration. The data verify the wall-interference theory even under conditions of extreme interference. A method yields reasonable estimates for the onset of Rae's minimum-speed limit. The rules for choosing model sizes to produce negligible wall effects are considerably in error and permit the use of excessively large models.
The NLO jet vertex in the small-cone approximation for kt and cone algorithms
NASA Astrophysics Data System (ADS)
Colferai, D.; Niccoli, A.
2015-04-01
We determine the jet vertex for Mueller-Navelet jets and forward jets in the small-cone approximation for two particular choices of jet algoritms: the kt algorithm and the cone algorithm. These choices are motivated by the extensive use of such algorithms in the phenomenology of jets. The differences with the original calculations of the small-cone jet vertex by Ivanov and Papa, which is found to be equivalent to a formerly algorithm proposed by Furman, are shown at both analytic and numerical level, and turn out to be sizeable. A detailed numerical study of the error introduced by the small-cone approximation is also presented, for various observables of phenomenological interest. For values of the jet "radius" R = 0 .5, the use of the small-cone approximation amounts to an error of about 5% at the level of cross section, while it reduces to less than 2% for ratios of distributions such as those involved in the measure of the azimuthal decorrelation of dijets.
Scoggins, John F; Weinberg, Daniel A
2017-06-01
Published estimates of the healthcare coinsurance elasticity coefficient have typically relied on annual observations of individual healthcare expenditures even though health plan membership and expenditures are traditionally reported in monthly units and several studies have stressed the need for demand models to recognize the episodic nature of healthcare. Summing individual healthcare expenditures into annual observations complicates two common challenges of statistical inference, heteroscedasticity, and regressor endogeneity. This paper estimates the elasticity coefficient using a monthly panel data model that addresses the heteroscedasticity and endogeneity problems with relative ease. Healthcare claims data from employees of King County, Washington, during 2005 to 2011 were used to estimate the mean point elasticity coefficient: -0.314 (0.015 standard error) to -0.145 (0.015 standard error) depending on model specification. These estimates bracket the -0.2 point estimate (range: -0.22 to -0.17) derived from the famous Rand Health Insurance Experiment. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
A relational leadership perspective on unit-level safety climate.
Thompson, Debra N; Hoffman, Leslie A; Sereika, Susan M; Lorenz, Holly L; Wolf, Gail A; Burns, Helen K; Minnier, Tamra E; Ramanujam, Rangaraj
2011-11-01
This study compared nursing staff perceptions of safety climate in clinical units characterized by high and low ratings of leader-member exchange (LMX) and explored characteristics that might account for differences. Frontline nursing leaders' actions are critical to ensure patient safety. Specific leadership behaviors to achieve this goal are underexamined. The LMX perspective has shown promise in nonhealthcare settings as a means to explain safety climate perceptions. Cross-sectional survey of staff (n = 711) and unit directors from 34 inpatient units in an academic medical center was conducted. Significant differences were found between high and low LMX scoring units on supervisor safety expectations, organizational learning-continuous improvement, total communication, feedback and communication about errors, and nonpunitive response to errors. The LMX perspective can be used to identify differences in perceptions of safety climate among nursing staff. Future studies are needed to identify strategies to improve staff safety attitudes and behaviors. Copyright © 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins
NASA Astrophysics Data System (ADS)
Wang, Congsi; Wang, Yan; Wang, Zhihai; Wang, Meng; Yuan, Shuai; Wang, Weifeng
2018-04-01
It is well known that calculating and reducing of radar cross section (RCS) of the active phased array antenna (APAA) are both difficult and complicated. It remains unresolved to balance the performance of the radiating and scattering when the RCS is reduced. Therefore, this paper develops a structure and scattering array factor coupling model of APAA based on the phase errors of radiated elements generated by structural distortion and installation error of the array. To obtain the optimal radiating and scattering performance, an integrated optimisation model is built to optimise the installation height of all the radiated elements in normal direction of the array, in which the particle swarm optimisation method is adopted and the gain loss and scattering array factor are selected as the fitness function. The simulation indicates that the proposed coupling model and integrated optimisation method can effectively decrease the RCS and that the necessary radiating performance can be simultaneously guaranteed, which demonstrate an important application value in engineering design and structural evaluation of APAA.
The evolution of Crew Resource Management training in commercial aviation
NASA Technical Reports Server (NTRS)
Helmreich, R. L.; Merritt, A. C.; Wilhelm, J. A.
1999-01-01
In this study, we describe changes in the nature of Crew Resource Management (CRM) training in commercial aviation, including its shift from cockpit to crew resource management. Validation of the impact of CRM is discussed. Limitations of CRM, including lack of cross-cultural generality are considered. An overarching framework that stresses error management to increase acceptance of CRM concepts is presented. The error management approach defines behavioral strategies taught in CRM as error countermeasures that are employed to avoid error, to trap errors committed, and to mitigate the consequences of error.
Peru, M; Peru, C; Mannocci, F; Sherriff, M; Buchanan, L S; Pitt Ford, T R
2006-02-01
The aim of this study was to evaluate root canals instrumented by dental students using the modified double-flared technique, nickel-titanium (NiTi) rotary System GT files and NiTi rotary ProTaper files by micro-computed tomography (MCT). A total of 36 root canals from 18 mesial roots of mandibular molar teeth were prepared; 12 canals were prepared with the modified double-flared technique, using K-flexofiles and Gates-Glidden burs; 12 canals were prepared using System GT and 12 using ProTaper rotary files. Each root was scanned using MCT preoperatively and postoperatively. At the coronal and mid-root sections, System GT and ProTaper files produced significantly less enlarged canal cross-sectional area, volume and perimeter than the modified double-flared technique (P < 0.05). In the mid-root sections there was significantly less thinning of the root structure towards the furcation with System GT and ProTaper (P < 0.05). The rotary techniques were both three times faster than the modified double-flared technique (P < 0.05). Qualitative evaluation of the preparations showed that both ProTaper and System GT were able to prepare root canals with little or no procedural error compared with the modified double-flared technique. Under the conditions of this study, inexperienced dental students were able to prepare curved root canals with rotary files with greater preservation of tooth structure, low risk of procedural errors and much quicker than with hand instruments.
Rosman, Mohamad; Wong, Tien Y; Tay, Wan-Ting; Tong, Louis; Saw, Seang-Mei
2009-08-01
To describe the prevalence and the risk factors of undercorrected refractive error in an adult urban Malay population. This population-based, cross-sectional study was conducted in Singapore in 3280 Malay adults, aged 40 to 80 years. All individuals were examined at a centralized clinic and underwent standardized interviews and assessment of refractive errors and presenting and best corrected visual acuities. Distance presenting visual acuity was monocularly measured by using a logarithm of the minimum angle of resolution (logMAR) number chart at a distance of 4 m, with the participants wearing their "walk-in" optical corrections (spectacles or contact lenses), if any. Refraction was determined by subjective refraction by trained, certified study optometrists. Best corrected visual acuity was monocularly assessed and recorded in logMAR scores using the same test protocol as was used for presenting visual acuity. Undercorrected refractive error was defined as an improvement of at least 0.2 logMAR (2 lines equivalent) in the best corrected visual acuity compared with the presenting visual acuity in the better eye. The mean age of the subjects included in our study was 58 +/- 11 years, and 52% of the subjects were women. The prevalence rate of undercorrected refractive error among Singaporean Malay adults in our study (n = 3115) was 20.4% (age-standardized prevalence rate, 18.3%). More of the women had undercorrected refractive error than the men (21.8% vs. 18.8%, P = 0.04). Undercorrected refractive error was also more common in subjects older than 50 years than in subjects aged 40 to 49 years (22.6% vs. 14.3%, P < 0.001). Non-spectacle wearers were more likely to have undercorrected refractive errors than were spectacle wearers (24.4% vs. 14.4%, P < 0.001). Persons with primary school education or less were 1.89 times (P = 0.03) more likely to have undercorrected refractive errors than those with post-secondary school education or higher. In contrast, persons with a history of eye disease were 0.74 times (P = 0.003) less likely to have undercorrected refractive errors. The proportion of undercorrected refractive error among the Singaporean Malay adults with refractive errors was higher than that of the Singaporean Chinese adults with refractive errors. Undercorrected refractive error is a significant cause of correctable visual impairment among Singaporean Malay adults, affecting one in five persons.
Sulaiman, Che Fatehah Che; Henn, Patrick; Smith, Simon; O'Tuathaigh, Colm M P
2017-10-01
Intensive workload and limited training opportunities for Irish non-consultant hospital doctors (NCHDs) has a negative effect on their health and well-being, and can result in burnout. Burnout affects physician performance and can lead to medical errors. This study examined the prevalence of burnout syndrome among Irish NCHDs and its association with self-reported medical error and poor quality of patient care. A cross-sectional quantitative survey-based design. All teaching hospitals affiliated with University College Cork. NCHDs of all grades and specialties. The following instruments were completed by all participants: Maslach Burnout Inventory-Human Service Survey (MBI-HSS), assessing three categories of burnout syndrome: Emotional exhaustion (EE), Personal Achievement (PA) and Depersonalization (DP); questions related to self-reported medical errors/poor patient care quality and socio-demographic information. Self-reported measures of burnout and poor quality of patient care. Prevalence of burnout among physicians (n = 265) was 26.4%. There was a significant gender difference for EE and DP, but none for PA. A positive weak correlation was observed between EE and DP with medical error or poor patient care. A negative association was reported between PA and medical error and reduced quality of patient care. Burnout is prevalent among NCHDs in Ireland. Burnout syndrome is associated with self-reported medical error and quality of care in this sample population. Measures need to be taken to address this issue, with a view to protecting health of NCHDs and maintaining quality of patient care. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Step-Count Accuracy of 3 Motion Sensors for Older and Frail Medical Inpatients.
McCullagh, Ruth; Dillon, Christina; O'Connell, Ann Marie; Horgan, N Frances; Timmons, Suzanne
2017-02-01
To measure the step-count accuracy of an ankle-worn accelerometer, a thigh-worn accelerometer, and a pedometer in older and frail inpatients. Cross-sectional design study. Research room within a hospital. Convenience sample of inpatients (N=32; age, ≥65 years) who were able to walk 20m independently with or without a walking aid. Patients completed a 40-minute program of predetermined tasks while wearing the 3 motion sensors simultaneously. Video recording of the procedure provided the criterion measurement of step count. Mean percentage errors were calculated for all tasks, for slow versus fast walkers, for independent walkers versus walking-aid users, and over shorter versus longer distances. The intraclass correlation was calculated, and accuracy was graphically displayed by Bland-Altman plots. Thirty-two patients (mean age, 78.1±7.8y) completed the study. Fifteen (47%) were women, and 17 (51%) used walking aids. Their median speed was .46m/s (interquartile range [IQR], .36-.66m/s). The ankle-worn accelerometer overestimated steps (median error, 1% [IQR, -3% to 13%]). The other motion sensors underestimated steps (median error, 40% [IQR, -51% to -35%] and 38% [IQR -93% to -27%], respectively). The ankle-worn accelerometer proved to be more accurate over longer distances (median error, 3% [IQR, 0%-9%]) than over shorter distances (median error, 10% [IQR, -23% to 9%]). The ankle-worn accelerometer gave the most accurate step-count measurement and was most accurate over longer distances. Neither of the other motion sensors had acceptable margins of error. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Marmamula, Srinivas; Madala, Sreenivas R; Rao, Gullapalli N
2012-03-01
To investigate the prevalence of uncorrected refractive errors, presbyopia and spectacle coverage in subjects aged 40 years or more using a novel Rapid Assessment of Visual Impairment (RAVI) methodology. A population-based cross-sectional study was conducted using cluster random sampling to enumerate 1700 subjects from 34 clusters predominantly inhabited by marine fishing communities in the Prakasam district of Andhra Pradesh, India. Unaided, aided and pinhole visual acuity (VA) was assessed using a Snellen chart at a distance of 6 m. Near vision was assessed using an N notation chart. Uncorrected refractive error was defined as presenting VA < 6/18 and improving to ≥6/18 with pinhole. Uncorrected presbyopia was defined as binocular near vision worse than N8 in subjects with binocular distance VA ≥ 6/18. 1560 subjects (response rate - 92%) were available for examination. Of these, 54.6% were female and 10.1% were ≥70 years of age. Refractive error was present in 250 individuals. It was uncorrected in 179 (unmet need) and corrected in 71 (met need) individuals. Among 1094 individuals with no distance visual impairment, presbyopia was present in 494 individuals. It was uncorrected in 439 (unmet need) and corrected in 55 individuals (met need). Spectacle coverage was 28.4% for refractive errors and 11.1% for presbyopia. There is a high unmet need for uncorrected refractive errors and presbyopia among marine fishing communities in the Prakasam district of South India. The data from this study can now be used as a baseline prior to the commencement of eye care services in this region. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.