Sin, Betül Ayşe; Öztuna, Derya; Gelincik, Aslı; Gürlek, Feridun; Baysan, Abdullah; Sin, Aytül Zerrin; Aydın, Ömür; Mısırlıgil, Zeynep
2016-01-01
"Vespid Allergy Quality of Life Questionnaire (VQLQ)" has been used to assess psychological burden of disease. The aim of this study was to evaluate validity, reliability and responsiveness to interventions of the Turkish version. The Turkish language Questionnaire (VQLQ-T) was administered to 81 patients with bee allergy and 65 patients with vespid allergy from different groups to achieve cross-sectional validation. To establish longitudinal validity, the questionnaire was administered to 36 patients treated with venom immunotherapy. The cross-sectional validation in patients with vespid venom allergy showed a correlation coefficient of 0.97 (Cronbach α). Spearman's correlation coefficient of the pretreatment VQLQ-T score with Expectation of Outcome (EoO) questionnaire score was 0.55 (p < 0.001). After treatment, correlation between VQLQ-T score and EoO score was 0.64 (p = 0.003) in these patients. The cross-sectional instrument validation for non-beekeepers with bee venom allergy yielded a correlation coefficient of 0.96 (Cronbach α). Spearman's correlation coefficient between pretreatment VQLQ-T score and EoO score was 0.47 (p < 0.001) and after treatment, correlation between VQLQ-T score and EoO score was 0.78 (p = 0.008) in these patients. These findings indicate cross-sectional validity of VQLQ-T. In the longitudinal validation, there was a positive correlation between EoO and VQLQ-T with a correlation coefficient of 0.562 (p < 0.001). While mean (±SD) VQLQ-T score was 5.27 (±1.29) in pretreatment, it was 2.78 (±1.01) after treatment (p < 0.001). The correlation between the mean change in VQLQ-T score and the mean change in EoO score was 0.42 (p = 0.011). The Turkish version of VQLQ-T enables measurement of Quality of Life (QoL) in patients with either vespid or bee venom allergy. Furthermore, responsiveness of this instrument demonstrates the questionnaire's ability to detect changes over time.
The Cross Validation of the Attitudes toward Mainstreaming Scale (ATMS).
ERIC Educational Resources Information Center
Berryman, Joan D.; Neal, W. R. Jr.
1980-01-01
Reliability and factorial validity of the Attitudes Toward Mainstreaming Scale was supported in a cross-validation study with teachers. Three factors emerged: learning capability, general mainstreaming, and traditional limiting disabilities. Factor intercorrelations varied from .42 to .55; correlations between total scores and individual factors…
Multifractal detrended cross-correlation analysis for two nonstationary signals.
Zhou, Wei-Xing
2008-06-01
We propose a method called multifractal detrended cross-correlation analysis to investigate the multifractal behaviors in the power-law cross-correlations between two time series or higher-dimensional quantities recorded simultaneously, which can be applied to diverse complex systems such as turbulence, finance, ecology, physiology, geophysics, and so on. The method is validated with cross-correlated one- and two-dimensional binomial measures and multifractal random walks. As an example, we illustrate the method by analyzing two financial time series.
Kaux, Jean-François; Delvaux, François; Schaus, Jean; Demoulin, Christophe; Locquet, Médéa; Buckinx, Fanny; Beaudart, Charlotte; Dardenne, Nadia; Van Beveren, Julien; Croisier, Jean-Louis; Forthomme, Bénédicte; Bruyère, Olivier
Translation and validation of algo-functional questionnaire. The lateral elbow tendinopathy is a common injury in tennis players and physical workers. The Patient-Rated Tennis Elbow Evaluation (PRTEE) Questionnaire was specifically designed to measure pain and functional limitations in patients with lateral epicondylitis (tennis elbow). First developed in English, this questionnaire has since been translated into several languages. The aims of the study were to translate and cross-culturally adapt the PRTEE questionnaire into French and to evaluate the reliability and validity of this translated version of the questionnaire (PRTEE-F). The PRTEE was translated and cross-culturally adapted into French according to international guidelines. To assess the reliability and validity of the PRTEE-F, 115 participants were asked twice to fill in the PRTEE-F, and once the Disabilities of Arm, Shoulder and Hand Questionnaire (DASH) and the Short Form Health Survey (SF-36). Internal consistency (using Cronbach's alpha), test-retest reliability (using intraclass correlation coefficient (ICC), standard error of measurement and minimal detectable change), and convergent and divergent validity (using the Spearman's correlation coefficients respectively with the DASH and with some subscales of the SF-36) were assessed. The PRTEE was translated into French without any problems. PRTEE-F showed a good test-retest reliability for the overall score (ICC 0.86) and for each item (ICC 0.8-0.96) and a high internal consistency (Cronbach's alpha = 0.98). The correlation analyses revealed high correlation coefficients between PRTEE-F and DASH (convergent validity) and, as expected, a low or moderate correlation with the divergent subscales of the SF-36 (discriminant validity). There was no floor or ceiling effect. The PRTEE questionnaire was successfully cross-culturally adapted into French. The PRTEE-F is reliable and valid for evaluating French-speaking patients with lateral elbow tendinopathy. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Genome-based prediction of test cross performance in two subsequent breeding cycles.
Hofheinz, Nina; Borchardt, Dietrich; Weissleder, Knuth; Frisch, Matthias
2012-12-01
Genome-based prediction of genetic values is expected to overcome shortcomings that limit the application of QTL mapping and marker-assisted selection in plant breeding. Our goal was to study the genome-based prediction of test cross performance with genetic effects that were estimated using genotypes from the preceding breeding cycle. In particular, our objectives were to employ a ridge regression approach that approximates best linear unbiased prediction of genetic effects, compare cross validation with validation using genetic material of the subsequent breeding cycle, and investigate the prospects of genome-based prediction in sugar beet breeding. We focused on the traits sugar content and standard molasses loss (ML) and used a set of 310 sugar beet lines to estimate genetic effects at 384 SNP markers. In cross validation, correlations >0.8 between observed and predicted test cross performance were observed for both traits. However, in validation with 56 lines from the next breeding cycle, a correlation of 0.8 could only be observed for sugar content, for standard ML the correlation reduced to 0.4. We found that ridge regression based on preliminary estimates of the heritability provided a very good approximation of best linear unbiased prediction and was not accompanied with a loss in prediction accuracy. We conclude that prediction accuracy assessed with cross validation within one cycle of a breeding program can not be used as an indicator for the accuracy of predicting lines of the next cycle. Prediction of lines of the next cycle seems promising for traits with high heritabilities.
Comparative assessment of three standardized robotic surgery training methods.
Hung, Andrew J; Jayaratna, Isuru S; Teruya, Kara; Desai, Mihir M; Gill, Inderbir S; Goh, Alvin C
2013-10-01
To evaluate three standardized robotic surgery training methods, inanimate, virtual reality and in vivo, for their construct validity. To explore the concept of cross-method validity, where the relative performance of each method is compared. Robotic surgical skills were prospectively assessed in 49 participating surgeons who were classified as follows: 'novice/trainee': urology residents, previous experience <30 cases (n = 38) and 'experts': faculty surgeons, previous experience ≥30 cases (n = 11). Three standardized, validated training methods were used: (i) structured inanimate tasks; (ii) virtual reality exercises on the da Vinci Skills Simulator (Intuitive Surgical, Sunnyvale, CA, USA); and (iii) a standardized robotic surgical task in a live porcine model with performance graded by the Global Evaluative Assessment of Robotic Skills (GEARS) tool. A Kruskal-Wallis test was used to evaluate performance differences between novices and experts (construct validity). Spearman's correlation coefficient (ρ) was used to measure the association of performance across inanimate, simulation and in vivo methods (cross-method validity). Novice and expert surgeons had previously performed a median (range) of 0 (0-20) and 300 (30-2000) robotic cases, respectively (P < 0.001). Construct validity: experts consistently outperformed residents with all three methods (P < 0.001). Cross-method validity: overall performance of inanimate tasks significantly correlated with virtual reality robotic performance (ρ = -0.7, P < 0.001) and in vivo robotic performance based on GEARS (ρ = -0.8, P < 0.0001). Virtual reality performance and in vivo tissue performance were also found to be strongly correlated (ρ = 0.6, P < 0.001). We propose the novel concept of cross-method validity, which may provide a method of evaluating the relative value of various forms of skills education and assessment. We externally confirmed the construct validity of each featured training tool. © 2013 BJU International.
Koritar, Priscila; Philippi, Sonia Tucunduva; Alvarenga, Marle dos Santos; Santos, Bernardo dos
2014-08-01
The scope of this study was to show the cross-cultural adaptation and validation of the Health and Taste Attitude Scale in Portuguese. The methodology included translation of the scale; evaluation of conceptual, operational and item-based equivalence by 14 experts and 51 female undergraduates; semantic equivalence and measurement assessment by 12 bilingual women by the paired t-test, the Pearson correlation coefficient and the coefficient intraclass correlation; internal consistency and test-retest reliability by Cronbach's alpha and intraclass correlation coefficient, respectively, after application on 216 female undergraduates; assessment of discriminant and concurrent validity via the t-test and Spearman's correlation coefficient, respectively, in addition to Confirmatory Factor and Exploratory Factor Analysis. The scale was considered adequate and easily understood by the experts and university students and presented good internal consistency and reliability (µ 0.86, ICC 0.84). The results show that the scale is valid and can be used in studies with women to better understand attitudes related to taste.
Rodrigues, Marcelo F; Michel-Crosato, Edgard; Cardoso, Jefferson R; Traebert, Jefferson
2009-06-01
Cross-cultural translation and psychometric testing. To translate and cross-culturally adapt the Quebec Back Pain Disability Scale (QDS) to Brazilian Portuguese and to examine its validity and reliability. Current literature shows the need to adopt reliable and internationally standardized methods for the analysis of low back pain. To our knowledge, this specific questionnaire has not been translated and validated for Portuguese-speaking patients. The translation and cross-cultural adaptation of the QDS were developed in agreement with internationally recommended methodology, and the resulting product was evaluated in this study with 54 consecutive patients. Internal consistency was obtained through Cronbach's alpha; reliability was estimated through the intraclass correlation coefficient and the Bland and Altman agreement (d = mean difference). Validity was determined by correlating the scores of the Brazil-QDS with the Brazilian version of the Roland-Morris Questionnaire and Visual Analogue Pain Scale by means of the Spearman rank correlation coefficient. The internal consistency obtained was excellent (Cronbach's alpha = 0.97). Intraobserver and interobserver reliability were considered strong (ICC = 0.93-d = 0.68 and 0.96-d = 0.57, respectively). The correlation with Brazilian Roland-Morris Questionnaire and with the Visual Analogue Scale was high (r = 0.857; r = 0.758, respectively). The data showed that the process of translation and cross-cultural adaptation were successful and that the adapted instrument demonstrated excellent psychometric properties.
Features of Cross-Correlation Analysis in a Data-Driven Approach for Structural Damage Assessment
Camacho Navarro, Jhonatan; Ruiz, Magda; Villamizar, Rodolfo; Mujica, Luis
2018-01-01
This work discusses the advantage of using cross-correlation analysis in a data-driven approach based on principal component analysis (PCA) and piezodiagnostics to obtain successful diagnosis of events in structural health monitoring (SHM). In this sense, the identification of noisy data and outliers, as well as the management of data cleansing stages can be facilitated through the implementation of a preprocessing stage based on cross-correlation functions. Additionally, this work evidences an improvement in damage detection when the cross-correlation is included as part of the whole damage assessment approach. The proposed methodology is validated by processing data measurements from piezoelectric devices (PZT), which are used in a piezodiagnostics approach based on PCA and baseline modeling. Thus, the influence of cross-correlation analysis used in the preprocessing stage is evaluated for damage detection by means of statistical plots and self-organizing maps. Three laboratory specimens were used as test structures in order to demonstrate the validity of the methodology: (i) a carbon steel pipe section with leak and mass damage types, (ii) an aircraft wing specimen, and (iii) a blade of a commercial aircraft turbine, where damages are specified as mass-added. As the main concluding remark, the suitability of cross-correlation features combined with a PCA-based piezodiagnostic approach in order to achieve a more robust damage assessment algorithm is verified for SHM tasks. PMID:29762505
Features of Cross-Correlation Analysis in a Data-Driven Approach for Structural Damage Assessment.
Camacho Navarro, Jhonatan; Ruiz, Magda; Villamizar, Rodolfo; Mujica, Luis; Quiroga, Jabid
2018-05-15
This work discusses the advantage of using cross-correlation analysis in a data-driven approach based on principal component analysis (PCA) and piezodiagnostics to obtain successful diagnosis of events in structural health monitoring (SHM). In this sense, the identification of noisy data and outliers, as well as the management of data cleansing stages can be facilitated through the implementation of a preprocessing stage based on cross-correlation functions. Additionally, this work evidences an improvement in damage detection when the cross-correlation is included as part of the whole damage assessment approach. The proposed methodology is validated by processing data measurements from piezoelectric devices (PZT), which are used in a piezodiagnostics approach based on PCA and baseline modeling. Thus, the influence of cross-correlation analysis used in the preprocessing stage is evaluated for damage detection by means of statistical plots and self-organizing maps. Three laboratory specimens were used as test structures in order to demonstrate the validity of the methodology: (i) a carbon steel pipe section with leak and mass damage types, (ii) an aircraft wing specimen, and (iii) a blade of a commercial aircraft turbine, where damages are specified as mass-added. As the main concluding remark, the suitability of cross-correlation features combined with a PCA-based piezodiagnostic approach in order to achieve a more robust damage assessment algorithm is verified for SHM tasks.
Lam, Simon C
2014-05-01
To perform detailed psychometric testing of the compliance with standard precautions scale (CSPS) in measuring compliance with standard precautions of clinical nurses and to conduct cross-cultural pilot testing and assess the relevance of the CSPS on an international platform. A cross-sectional and correlational design with repeated measures. Nursing students from a local registered nurse training university, nurses from different hospitals in Hong Kong, and experts in an international conference. The psychometric properties of the CSPS were evaluated via internal consistency, 2-week and 3-month test-retest reliability, concurrent validation, and construct validation. The cross-cultural pilot testing and relevance check was examined by experts on infection control from various developed and developing regions. Among 453 participants, 193 were nursing students, 165 were enrolled nurses, and 95 were registered nurses. The results showed that the CSPS had satisfactory reliability (Cronbach α = 0.73; intraclass correlation coefficient, 0.79 for 2-week test-retest and 0.74 for 3-month test-retest) and validity (optimum correlation with criterion measure; r = 0.76, P < .001; satisfactory results on known-group method and hypothesis testing). A total of 19 experts from 16 countries assured that most of the CSPS findings were relevant and globally applicable. The CSPS demonstrated satisfactory results on the basis of the standard international criteria on psychometric testing, which ascertained the reliability and validity of this instrument in measuring the compliance of clinical nurses with standard precautions. The cross-cultural pilot testing further reinforced the instrument's relevance and applicability in most developed and developing regions.
Cross-Validation of a Short Form of the Marlowe-Crowne Social Desirability Scale.
ERIC Educational Resources Information Center
Zook, Avery, II; Sipps, Gary J.
1985-01-01
Presents a cross-validation of Reynolds' short form of the Marlowe-Crowne Social Desirability Scale (N=233). Researchers administered 13 items as a separate entity, calculated Cronbach's Alpha for each sex, and computed test-retest correlation for one group. Concluded that the short form is a viable alternative. (Author/NRB)
Ko, Jupil; Rosen, Adam B; Brown, Cathleen N
2015-12-01
The Cumberland Ankle Instability Tool (CAIT) is a valid and reliable patient reported outcome used to assess the presence and severity of chronic ankle instability (CAI). The CAIT has been cross-culturally adapted into other languages for use in non-English speaking populations. However, there are no valid questionnaires to assess CAI in individuals who speak Korean. The purpose of this study was to translate, cross-culturally adapt, and validate the CAIT, for use in a Korean-speaking population with CAI. Cross-cultural reliability study. The CAIT was cross-culturally adapted into Korean according to accepted guidelines and renamed the Cumberland Ankle Instability Tool-Korean (CAIT-K). Twenty-three participants (12 males, 11 females) who were bilingual in English and Korean were recruited and completed the original and adapted versions to assess agreement between versions. An additional 168 national level Korean athletes (106 male, 62 females; age = 20.3 ± 1.1 yrs), who participated in ≥ 90 minutes of physical activity per week, completed the final version of the CAIT-K twice within 14 days. Their completed questionnaires were assessed for internal consistency, test-retest reliability, criterion validity, and construct validity. For bilingual participants, intra-class correlation coefficients (ICC2,1) between the CAIT and the CAIT-K for test-retest reliability were 0.95 (SEM=1.83) and 0.96 (SEM=1.50) in right and left limbs, respectively. The Cronbach's alpha coefficients were 0.92 and 0.90 for the CAIT-K in right and left limbs, respectively. For native Korean speakers, the CAIT-K had high internal consistency (Cronbach's α=0.89) and intra-class correlation coefficient (ICC2,1 = 0.94, SEM=1.72), correlation with the physical component score (rho=0.70, p = 0.001) of the Short-Form Health Survey (SF-36), and the Kaiser-Meyer-Olkin score was 0.87. The original CAIT was translated, cross-culturally adapted, and validated from English to Korean. The CAIT-K appears to be valid and reliable and could be useful in assessing the Korean speaking population with CAI.
A Swedish cross-cultural adaptation and validation of the Tinnitus Functional Index.
Hoff, Maria; Kähäri, Kim
2017-04-01
The Tinnitus Functional Index (TFI) is a recent self-report instrument for tinnitus with potential advantages over other existing instruments, including a demonstrated high responsiveness. The objectives of this study were to translate and cross-culturally adapt the TFI into Swedish and to investigate its validity and reliability. The development of the Swedish version (TFI-SE) followed published guidelines on cross-cultural adaptation of health questionnaires. Validity and reliability was investigated by correlating responses on the TFI-SE with other tinnitus measures [Tinnitus Handicap Inventory (THI) and visual analogue scale (VAS)] and a scale measuring anxiety and depression (HADS). Consecutively recruited tinnitus patients (n = 100) from four Swedish clinics completed the questionnaires. The mean age of the sample was 51 years (SD =17). The internal consistency of the TFI-SE was good (α = 0.95) and the test-retest reliability was high (ICC =0.93). Our results supported the eight-factor structure proposed for the original TFI, and a high correlation between the TFI-SE and the THI (r = 0.8; p < 0.01) and lower correlations between the TFI-SE and the HADS-D (r = 0.60; p < 0.01) and HADS-A (r = 0.59; p < 0.01) confirmed satisfactory convergent and discriminant validity. We found that the Swedish translation and cross-cultural adaptation of the TFI is valid and reliable for use with adult tinnitus patients.
Konzelmann, M; Burrus, C; Hilfiker, R; Rivier, G; Deriaz, O; Luthi, F
2015-03-01
Functional evaluation of upper limb is not only based on clinical findings but requires self-administered questionnaires to address patients' perspective. The Hand Function Sort (HFS©) was only validated in English. The aim of this study was the French cross cultural adaptation and validation of the HFS© (HFS-F). 150 patients with various upper limbs impairments were recruited in a rehabilitation center. Translation and cross-cultural adaptation were made according to international guidelines. Construct validity was estimated through correlations with Disabilities Arm Shoulder and Hand (DASH) questionnaire, SF-36 mental component summary (MCS),SF-36 physical component summary (PCS) and pain intensity. Internal consistency was assessed by Cronbach's α and test-retest reliability by intraclass correlation. Cronbach's α was 0.98, test-retest reliability was excellent at 0.921 (95 % CI 0.871-0.971) same as original HFS©. Correlations with DASH were-0.779 (95 % CI -0.847 to -0.685); with SF 36 PCS 0.452 (95 % CI 0.276-0.599); with pain -0.247 (95 % CI -0.429 to -0.041); with SF 36 MCS 0.242 (95 % CI 0.042-0.422). There were no floor or ceiling effects. The HFS-F has the same good psychometric properties as the original HFS© (internal consistency, test retest reliability, convergent validity with DASH, divergent validity with SF-36 MCS, and no floor or ceiling effects). The convergent validity with SF-36 PCS was poor; we found no correlation with pain. The HFS-F could be used with confidence in a population of working patients. Other studies are necessary to study its psychometric properties in other populations.
Certification in Structural Health Monitoring Systems
2011-09-01
validation [3,8]. This may be accomplished by computing the sum of squares of pure error ( SSPE ) and its associated squared correlation [3,8]. To compute...these values, a cross- validation sample must be established. In general, if the SSPE is high, the model does not predict well on independent data...plethora of cross- validation methods, some of which are more useful for certain models than others [3,8]. When possible, a disclosure of the SSPE
Cross-cultural adaptation and validation of Persian Achilles tendon Total Rupture Score.
Ansari, Noureddin Nakhostin; Naghdi, Soofia; Hasanvand, Sahar; Fakhari, Zahra; Kordi, Ramin; Nilsson-Helander, Katarina
2016-04-01
To cross-culturally adapt the Achilles tendon Total Rupture Score (ATRS) to Persian language and to preliminary evaluate the reliability and validity of a Persian ATRS. A cross-sectional and prospective cohort study was conducted to translate and cross-culturally adapt the ATRS to Persian language (ATRS-Persian) following steps described in guidelines. Thirty patients with total Achilles tendon rupture and 30 healthy subjects participated in this study. Psychometric properties of floor/ceiling effects (responsiveness), internal consistency reliability, test-retest reliability, standard error of measurement (SEM), smallest detectable change (SDC), construct validity, and discriminant validity were tested. Factor analysis was performed to determine the ATRS-Persian structure. There were no floor or ceiling effects that indicate the content and responsiveness of ATRS-Persian. Internal consistency was high (Cronbach's α 0.95). Item-total correlations exceeded acceptable standard of 0.3 for the all items (0.58-0.95). The test-retest reliability was excellent [(ICC)agreement 0.98]. SEM and SDC were 3.57 and 9.9, respectively. Construct validity was supported by a significant correlation between the ATRS-Persian total score and the Persian Foot and Ankle Outcome Score (PFAOS) total score and PFAOS subscales (r = 0.55-0.83). The ATRS-Persian significantly discriminated between patients and healthy subjects. Explanatory factor analysis revealed 1 component. The ATRS was cross-culturally adapted to Persian and demonstrated to be a reliable and valid instrument to measure functional outcomes in Persian patients with Achilles tendon rupture. II.
Yapali, Gökmen; Günel, Mintaze Kerem; Karahan, Sevilay
2012-05-15
The study design was cross-cultural adaptation and investigation of reliability and validity of the Copenhagen Neck Functional Disability Scale (CNFDS). The aim of this study was to translate the CNFDS into Turkish language and assess its reliability and validity among patients with neck pain in Turkish population. The CNFDS is a reliable and valid evaluation instrument for disability, but there is no published the Turkish version of the CNFDS. One hundred one subjects who had chronic neck pain were included in this study. The CNFDS, Neck Pain and Disability Scale, and visual analogue scale were administered to all subjects. For investigating test-retest reliability, correlation between CNFDS scores, applied at 1-week interval, intraclass correlation coefficient score for test-retest reliability was 0.86 (95% confidence interval = 0.679-0.935). There was no difference between test-retest scores (P < 0.001). For investigating concurrent validity, correlation between total score of the CNFDS and the mean visual analogue scale was r = 0.73 (P < 0.001). Concurrent validity of the CNFDS was very good. For investigating construct validity, correlation between total score of the CNFDS and the Neck Pain and Disability Scale was r = 0.78 (P < 0.001). Construct validity of the CNFDS was also very good. Our results suggest that the Turkish version of the CNFDS is a reliable and valid instrument for Turkish people.
Dynamic Time Warping compared to established methods for validation of musculoskeletal models.
Gaspar, Martin; Welke, Bastian; Seehaus, Frank; Hurschler, Christof; Schwarze, Michael
2017-04-11
By means of Multi-Body musculoskeletal simulation, important variables such as internal joint forces and moments can be estimated which cannot be measured directly. Validation can ensued by qualitative or by quantitative methods. Especially when comparing time-dependent signals, many methods do not perform well and validation is often limited to qualitative approaches. The aim of the present study was to investigate the capabilities of the Dynamic Time Warping (DTW) algorithm for comparing time series, which can quantify phase as well as amplitude errors. We contrast the sensitivity of DTW with other established metrics: the Pearson correlation coefficient, cross-correlation, the metric according to Geers, RMSE and normalized RMSE. This study is based on two data sets, where one data set represents direct validation and the other represents indirect validation. Direct validation was performed in the context of clinical gait-analysis on trans-femoral amputees fitted with a 6 component force-moment sensor. Measured forces and moments from amputees' socket-prosthesis are compared to simulated forces and moments. Indirect validation was performed in the context of surface EMG measurements on a cohort of healthy subjects with measurements taken of seven muscles of the leg, which were compared to simulated muscle activations. Regarding direct validation, a positive linear relation between results of RMSE and nRMSE to DTW can be seen. For indirect validation, a negative linear relation exists between Pearson correlation and cross-correlation. We propose the DTW algorithm for use in both direct and indirect quantitative validation as it correlates well with methods that are most suitable for one of the tasks. However, in DV it should be used together with methods resulting in a dimensional error value, in order to be able to interpret results more comprehensible. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cross Validated Temperament Scale Validities Computed Using Profile Similarity Metrics
2017-04-27
true at both the item and the scale level. 6 Moreover, the correlation between conventional scores and distance scores for these types of scales...have a perfect negative correlation , r = -1.00. From this perspective, conventional and distance scores are completely redundant. Therefore, we argue... correlation between each respondent’s rating profile and the scale key: shape-scores = rx,k. 2. Rating elevation difference, which is computed as the
Joint multifractal analysis based on wavelet leaders
NASA Astrophysics Data System (ADS)
Jiang, Zhi-Qiang; Yang, Yan-Hong; Wang, Gang-Jin; Zhou, Wei-Xing
2017-12-01
Mutually interacting components form complex systems and these components usually have long-range cross-correlated outputs. Using wavelet leaders, we propose a method for characterizing the joint multifractal nature of these long-range cross correlations; we call this method joint multifractal analysis based on wavelet leaders (MF-X-WL). We test the validity of the MF-X-WL method by performing extensive numerical experiments on dual binomial measures with multifractal cross correlations and bivariate fractional Brownian motions (bFBMs) with monofractal cross correlations. Both experiments indicate that MF-X-WL is capable of detecting cross correlations in synthetic data with acceptable estimating errors. We also apply the MF-X-WL method to pairs of series from financial markets (returns and volatilities) and online worlds (online numbers of different genders and different societies) and determine intriguing joint multifractal behavior.
Cross-cultural adaptation and validation of the neonatal/infant Braden Q risk assessment scale.
de Lima, Edson Luiz; de Brito, Maria José Azevedo; de Souza, Diba Maria Sebba Tosta; Salomé, Geraldo Magela; Ferreira, Lydia Masako
2016-02-01
To translate into Brazilian Portuguese and cross-culturally adapt the Neonatal/Infant Braden Q Risk Assessment Scale (Neonatal/Infant Braden Q Scale), and test the psychometric properties, reproducibility and validity of the instrument. There is a lack of studies on the development of pressure ulcers in children, especially in neonates. Thirty professionals participated in the cross-cultural adaptation of the Brazilian-Portuguese version of the scale. Fifty neonates of both sexes were assessed between July 2013 and June 2014. Reliability and reproducibility were tested in 20 neonates and construct validity was measured by correlating the Neonatal/Infant Braden Q Scale with the Braden Q Risk Assessment Scale (Braden Q Scale). Discriminant validity was assessed by comparing the scores of neonates with and without ulcers. The scale showed inter-rater reliability (ICC = 0.98; P < 0.001) and intra-rater reliability (ICC = 0.79; P < 0.001). A strong correlation was found between the Neonatal/Infant Braden Q Scale and Braden Q Scale (r = 0.96; P < 0.001). The cross-culturally adapted Brazilian version of the Neonatal/Infant Braden Q Scale is a reliable instrument, showing face, content and construct validity. Copyright © 2015 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Jain, Meena; Tandon, Shourya; Sharma, Ankur; Jain, Vishal; Rani Yadav, Nisha
2018-01-01
Background: An appropriate scale to assess the dental anxiety of Hindi speaking population is lacking. This study, therefore, aims to evaluate the psychometric properties of Hindi version of one of the oldest dental anxiety scale, Corah’s Dental Anxiety Scale (CDAS) in Hindi speaking Indian adults. Methods: A total of 348 subjects from the outpatient department of a dental hospital in India participated in this cross-sectional study. The scale was cross-culturally adapted by forward and backward translation, committee review and pretesting method. The construct validity of the translated scale was explored with exploratory factor analysis. The correlation of the Hindi version of CDAS with visual analogue scale (VAS) was used to measure the convergent validity. Reliability was assessed through calculations of Cronbach’s alpha and intra class correlation 48 forms were completed for test-retest. Results: Prevalence of dental anxiety in the sample within the age range of 18-80 years was 85.63% [95% CI: 0.815-0.891]. The response rate was 100 %. Kaiser-Meyer-Olkin (KMO) test value was 0.776. After factor analysis, a single factor (dental anxiety) was obtained with 4 items.The single factor model explained 61% variance. Pearson correlation coefficient between CDASand VAS was 0.494. Test-retest showed the Cronbach’s alpha value of 0.814. The test-retest intraclass correlation coefficient of the total CDAS score was 0.881 [95% CI: 0.318-0.554]. Conclusion: Hindi version of CDAS is a valid and reliable scale to assess dental anxiety in Hindi speaking population. Convergent validity is well recognized but discriminant validity is limited and requires further study. PMID:29744307
Jain, Meena; Tandon, Shourya; Sharma, Ankur; Jain, Vishal; Rani Yadav, Nisha
2018-01-01
Background: An appropriate scale to assess the dental anxiety of Hindi speaking population is lacking. This study, therefore, aims to evaluate the psychometric properties of Hindi version of one of the oldest dental anxiety scale, Corah's Dental Anxiety Scale (CDAS) in Hindi speaking Indian adults. Methods: A total of 348 subjects from the outpatient department of a dental hospital in India participated in this cross-sectional study. The scale was cross-culturally adapted by forward and backward translation, committee review and pretesting method. The construct validity of the translated scale was explored with exploratory factor analysis. The correlation of the Hindi version of CDAS with visual analogue scale (VAS) was used to measure the convergent validity. Reliability was assessed through calculations of Cronbach's alpha and intra class correlation 48 forms were completed for test-retest. Results: Prevalence of dental anxiety in the sample within the age range of 18-80 years was 85.63% [95% CI: 0.815-0.891]. The response rate was 100 %. Kaiser-Meyer-Olkin (KMO) test value was 0.776. After factor analysis, a single factor (dental anxiety) was obtained with 4 items.The single factor model explained 61% variance. Pearson correlation coefficient between CDASand VAS was 0.494. Test-retest showed the Cronbach's alpha value of 0.814. The test-retest intraclass correlation coefficient of the total CDAS score was 0.881 [95% CI: 0.318-0.554]. Conclusion: Hindi version of CDAS is a valid and reliable scale to assess dental anxiety in Hindi speaking population. Convergent validity is well recognized but discriminant validity is limited and requires further study.
Igwesi-Chidobe, Chinonso N; Obiekwe, Chinwe; Sorinola, Isaac O; Godfrey, Emma L
2017-12-14
Cross-culturally adapt and validate the Igbo Roland Morris Disability Questionnaire. Cross-cultural adaptation, test-retest, and cross-sectional psychometric testing. Roland Morris Disability Questionnaire was forward and back translated by clinical/non-clinical translators. An expert committee appraised the translations. Twelve participants with chronic low back pain pre-tested the measure in a rural Nigerian community. Internal consistency using Cronbach's alpha; test-retest reliability using intra-class correlation coefficient and Bland-Altman plot; and minimal detectable change were investigated in a convenient sample of 50 people with chronic low back pain in rural and urban Nigeria. Pearson's correlation analyses using the eleven-point box scale and back performance scale, and exploratory factor analysis were used to examine construct validity in a random sample of 200 adults with chronic low back pain in rural Nigeria. Ceiling and floor effects were investigated in the two samples. Modifications gave the option of interviewer-administration and reflected Nigerian social context. The measure had excellent internal consistency (α = 0.91) and intraclass correlation coefficient (ICC =0.84), moderately high correlations (r > 0.6) with performance-based disability and pain intensity, and a predominant uni-dimensional structure, with no ceiling or floor effects. Igbo Roland Morris Disability Questionnaire is a valid and reliable measure of pain-related disability. Implications for rehabilitation Low back pain is the leading cause of years lived with disability worldwide, and is particularly prevalent in rural Nigeria, but there are no self-report measures to assess its impact due to low literacy rates. This study describes the cross-cultural adaptation and validation of a core self-report back pain specific disability measure in a low-literate Nigerian population. The Igbo Roland Morris Disability Questionnaire is a reliable and valid measure of self-reported disability in Igbo populations as indicated by excellent internal consistency (α = 0.91) and intra-class correlation coefficient (ICC =0.84), moderately high correlations (r > 0.6) with performance-based disability and pain intensity that supports a pain-related disability construct, a predominant one factor structure with no ceiling or floor effects. The measure will be useful for researchers and clinicians examining the factors associated with low back pain disability or the effects of interventions on low back pain disability in this culture. This measure will support global health initiatives concurrently involving people from several cultures or countries, and may inform cross-cultural disability research in other populations.
Mulero-Portela, Ana L.; Colón-Santaella, Carmen L.; Cruz-Gomez, Cynthia
2010-01-01
The purpose of this study was to perform a cross-cultural adaptation of the Disability of Arm, Shoulder, and Hand (DASH) questionnaire to Spanish for Puerto Rico. Five steps were followed for the cross-cultural adaptation: forward translations into Spanish for Puerto Rico, synthesis of the translations, back translations into English, revision by an expert committee, and field test of the prefinal version. Psychometric characteristics of reliability and construct validity were evaluated for the final version. Internal consistency of the final version was high (Cronbach's α = 0.97) and item-to-total correlations were moderate (range from 0.44 to 0.85). Construct validity was evaluated by correlating the DASH with the scales of the Functional Assessment of Cancer Therapy - Breast. Fair to moderate correlations found in this study between the DASH and most scales of the Functional Assessment of Cancer Therapy - Breast support the construct validity of the Puerto Rico-Spanish DASH. The final version of the questionnaire was revised and approved by the Institute for Work and Health of Canada. Revisions to the original DASH English version are recommended. This version of the DASH is valid and reliable, and it can be used to evaluate outcomes in both clinical and research settings. PMID:19901616
ERIC Educational Resources Information Center
van den Broek, Anneke; Golden, Charles J.; Loonstra, Ann; Ghinglia, Katheryne; Goldstein, Diane
1998-01-01
Indicated excellent cross-validations with correlation of 0.99 for past formulas (J. L. Woodard and B. N. Axelrod, 1995; B. N. Axelrod et al, 1996) for estimating the Wechsler Memory Scale- Revised General Memory and Delayed Recall Indexes. Over 85% of the estimated scores were within 10 points of actual scores. Age, education, diagnosis, and IQ…
Cross-validating a bidimensional mathematics anxiety scale.
Haiyan Bai
2011-03-01
The psychometric properties of a 14-item bidimensional Mathematics Anxiety Scale-Revised (MAS-R) were empirically cross-validated with two independent samples consisting of 647 secondary school students. An exploratory factor analysis on the scale yielded strong construct validity with a clear two-factor structure. The results from a confirmatory factor analysis indicated an excellent model-fit (χ(2) = 98.32, df = 62; normed fit index = .92, comparative fit index = .97; root mean square error of approximation = .04). The internal consistency (.85), test-retest reliability (.71), interfactor correlation (.26, p < .001), and positive discrimination power indicated that MAS-R is a psychometrically reliable and valid instrument for measuring mathematics anxiety. Math anxiety, as measured by MAS-R, correlated negatively with student achievement scores (r = -.38), suggesting that MAS-R may be a useful tool for classroom teachers and other educational personnel tasked with identifying students at risk of reduced math achievement because of anxiety.
Decorrelation of the true and estimated classifier errors in high-dimensional settings.
Hanczar, Blaise; Hua, Jianping; Dougherty, Edward R
2007-01-01
The aim of many microarray experiments is to build discriminatory diagnosis and prognosis models. Given the huge number of features and the small number of examples, model validity which refers to the precision of error estimation is a critical issue. Previous studies have addressed this issue via the deviation distribution (estimated error minus true error), in particular, the deterioration of cross-validation precision in high-dimensional settings where feature selection is used to mitigate the peaking phenomenon (overfitting). Because classifier design is based upon random samples, both the true and estimated errors are sample-dependent random variables, and one would expect a loss of precision if the estimated and true errors are not well correlated, so that natural questions arise as to the degree of correlation and the manner in which lack of correlation impacts error estimation. We demonstrate the effect of correlation on error precision via a decomposition of the variance of the deviation distribution, observe that the correlation is often severely decreased in high-dimensional settings, and show that the effect of high dimensionality on error estimation tends to result more from its decorrelating effects than from its impact on the variance of the estimated error. We consider the correlation between the true and estimated errors under different experimental conditions using both synthetic and real data, several feature-selection methods, different classification rules, and three error estimators commonly used (leave-one-out cross-validation, k-fold cross-validation, and .632 bootstrap). Moreover, three scenarios are considered: (1) feature selection, (2) known-feature set, and (3) all features. Only the first is of practical interest; however, the other two are needed for comparison purposes. We will observe that the true and estimated errors tend to be much more correlated in the case of a known feature set than with either feature selection or using all features, with the better correlation between the latter two showing no general trend, but differing for different models.
Tilov, Boris; Dimitrova, Donka; Stoykova, Maria; Tornjova, Bianka; Foreva, Gergana; Stoyanov, Drozdstoj
2012-12-01
Health-care professions have long been considered prone to work-related stress, yet recent research in Bulgaria indicates alarmingly high levels of burnout. Cloninger's inventory is used to analyse and evaluate correlation between personality characteristics and degree of burnout syndrome manifestation among the risk categories of health-care professionals. The primary goal of this study was to test the conceptual validity and cross-cultural applicability of the revised TCI (TCI-R), developed in the United States, in a culturally, socially and economically diverse setting. Linguistic validation, test-retest studies, statistical and expert analyses were performed to assess cross-cultural applicability of the revised Cloninger's temperament and character inventory in Bulgarian, its reliability and internal consistency and construct validity. The overall internal consistency of TCI-R and its scales as well as the interscale and test-retest correlations prove that the translated version of the questionnaire is acceptable and cross-culturally applicable for the purposes of studying organizational stress and burnout risk in health-care professionals. In general the cross-cultural adaptation process, even if carried out in a rigorous way, does not always lead to the best target version and suggests it would be useful to develop new scales specific to each culture and, at the same time, to think about the trans-cultural adaptation. © 2012 Blackwell Publishing Ltd.
The validity and reliability of tinnitus handicap inventory Thai version.
Limviriyakul, Siriporn; Supavanich, Walop
2012-11-01
Demonstrate the reliability and validity of the Tinnitus Handicap Inventory Thai Version (THI-T), a self-report measure of tinnitus. A cross-sectional psychometric validation study was used to determine internal consistency reliability and validity of the Tinnitus Handicap Inventory Thai Version at the Otoneurology clinic at Tertiary care center The cross-cultural adaptation of the Tinnitus Handicapped Inventory English version (Newman et al, 1996) was translated into Thai version following the steps indicated by Guillemin et al. The reliability was constructed by using Cronbach's coefficient alpha. The validity was analyzed by the correlation between Tinnitus Handicap Inventory Thai version and the 36-items short form health survey and visual analog scale using Spearman and Pearson test. The result showed good internal consistency reliabilities of total, functional, emotional, and catastrophic scale (a = 0.902, 0.804, 0.831 and 0.661, respectively) of Tinnitus Handicap Inventory Thai Version. Spearman correlation showed the significant correlation of Tinnitus Handicap Inventory to 36-items short form health survey and visual analog scale. Tinnitus Handicap Inventory Thai Version will be a vigorous tool in evaluating tinnitus patients as well as monitoring the progress of their symptoms.
Cross-Cultural Adaptation and Validation of the FRAIL Scale to Assess Frailty in Mexican Adults.
Rosas-Carrasco, Oscar; Cruz-Arenas, Esteban; Parra-Rodríguez, Lorena; García-González, Ana Isabel; Contreras-González, Luis Horacio; Szlejf, Claudia
2016-12-01
The objectives of this study were to cross-culturally adapt and validate the FRAIL scale in Mexican community-dwelling adults. Cross-sectional analysis of a prospective cohort. The FraDysMex study, a 2-round evaluation of community-dwelling adults from 2 municipalities in Mexico City. Participants were 606 men and women living in the designated area in Mexico City. Interviewers obtained data regarding demographics, comorbidities, mental status, nutritional status, dependency in activities of daily living, quality of life, mobility, balance, and strength. The FRAIL scale translated to Spanish and the Fried criteria were applied to screen frailty. The Mexican Spanish version of the FRAIL scale showed internal consistency (4 of 5 items in the scale correlated to the scale's total score, rho = 0.41-0.74), external consistency (interrater correlation CCI = 0.82), known-group validity based on age (9.6% of frailty in persons ≥50 years × 3.2% in persons <50 years, P = .001), convergent validity with the Fried criteria (CCI = 0.63), and the scale was also correlated with other measures related to frailty (such as age, quality of life, self-rated health status, cognition, dependency, nutritional status, depression, and physical performance). The FRAIL scale was successfully adapted to Mexican Spanish and validated in community-dwelling Mexican adults. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Measuring Advance Care Planning: Optimizing the Advance Care Planning Engagement Survey.
Sudore, Rebecca L; Heyland, Daren K; Barnes, Deborah E; Howard, Michelle; Fassbender, Konrad; Robinson, Carole A; Boscardin, John; You, John J
2017-04-01
A validated 82-item Advance Care Planning (ACP) Engagement Survey measures a broad range of behaviors. However, concise surveys are needed. The objective of this study was to validate shorter versions of the survey. The survey included 57 process (e.g., readiness) and 25 action items (e.g., discussions). For item reduction, we systematically eliminated questions based on face validity, item nonresponse, redundancy, ceiling effects, and factor analysis. We assessed internal consistency (Cronbach's alpha) and construct validity with cross-sectional correlations and the ability of the progressively shorter survey versions to detect change one week after exposure to an ACP intervention (Pearson correlation coefficients). Five hundred one participants (four Canadian and three US sites) were included in item reduction (mean age 69 years [±10], 41% nonwhite). Because of high correlations between readiness and action items, all action items were removed. Because of high correlations and ceiling effects, two process items were removed. Successive factor analysis then created 55-, 34-, 15-, nine-, and four-item versions; 664 participants (from three US ACP clinical trials) were included in validity analysis (age 65 years [±8], 72% nonwhite, 34% Spanish speaking). Cronbach's alphas were high for all versions (four items 0.84-55 items 0.97). Compared with the original survey, cross-sectional correlations were high (four items 0.85; 55 items 0.97) as were delta correlations (four items 0.68; 55 items 0.93). Shorter versions of the ACP Engagement Survey are valid, internally consistent, and able to detect change across a broad range of ACP behaviors for English and Spanish speakers. Shorter ACP surveys can efficiently measure broad ACP behaviors in research and clinical settings. Published by Elsevier Inc.
Tuğay, Baki Umut; Tuğay, Nazan; Güney, Hande; Kınıklı, Gizem İrem; Yüksel, İnci; Atilla, Bülent
2016-01-01
The Oxford Knee Score (OKS) is a valid, short, self-administered, and site- specific outcome measure specifically developed for patients with knee arthroplasty. This study aimed to cross-culturally adapt and validate the OKS to be used in Turkish-speaking patients with osteoarthritis of the knee. The OKS was translated and culturally adapted according to the guidelines in the literature. Ninety-one patients (mean age: 55.89±7.85 years) with knee osteoarthritis participated in the study. Patients completed the Turkish version of the Oxford Knee Score (OKS-TR), Short-Form 36 Health Survey (SF-36), and Western Ontario and McMaster Universities Index (WOMAC) questionnaires. Internal consistency was tested using Cronbach's α coefficient. Patients completed the OKS-TR questionnaire twice in 7 days to determine the reproducibility. Correlation between the total results of both tests was determined by Spearman's correlation coefficient and intraclass correlation coefficients (ICC). Validity was assessed by calculating Spearman's correlation coefficient between the OKS, WOMAC, and SF-36 scores. Floor and ceiling effects were analyzed. Internal consistency was high (Cronbach's α: 0.90). The reproducibility tested by 2 different methods showed no significant difference (p>0.05). The construct validity analyses showed a significant correlation between the OKS and the other scores (p<0.05). There was no floor or ceiling effect in total OKS score. The OKS-TR is a reliable and valid measure for the self-assessment of pain and function in Turkish-speaking patients with osteoarthritis of the knee.
van Ark, Mathijs; Zwerver, Johannes; Diercks, Ronald L; van den Akker-Scheek, Inge
2014-08-11
Lateral Epicondylalgia (LE) is a common injury for which no reliable and valid measure exists to determine severity in the Dutch language. The Patient-Rated Tennis Elbow Evaluation (PRTEE) is the first questionnaire specifically designed for LE but in English. The aim of this study was to translate into Dutch and cross-culturally adapt the PRTEE and determine reliability and validity of the PRTEE-D (Dutch version). The PRTEE was cross-culturally adapted according to international guidelines. Participants (n = 122) were asked to fill out the PRTEE-D twice with a one week interval to assess test-retest reliability. Internal consistency of the PRTEE-D was determined by calculating Crohnbach's alphas for the questionnaire and subscales. Intraclass Correlation Coefficients (ICC) were calculated for the overall PRTEE-D score, pain and function subscale and individual questions to determine test-retest reliability. Additionally, the Disabilities for the Arm, Shoulder and Hand questionnaire (DASH) and Visual Analogue Scale (VAS) pain scores were obtained from 30 patients to assess construct validity; Spearman's correlation coefficients were calculated between the PRTEE-D (subscales) and DASH and VAS-pain scores. The PRTEE was successfully cross-culturally adapted into Dutch (PRTEE-D). Crohnbach's alpha for the first assessment of the PRTEE-D was 0.98; Crohnbach's alpha was 0.93 for the pain subscale and 0.97 for the function subscale. ICC for the PRTEE-D was 0.98; subscales also showed excellent ICC values (pain scale 0.97 and function scale 0.97). A significant moderate correlation exists between PRTEE-D and DASH (0.65) and PRTEE-D and VAS pain (0.68). The PRTEE was successfully cross-culturally adapted and this study showed that the PRTEE-D is reliable and valid to obtain an indication of severity of LE. An easy-to-use instrument for practitioners is now available and this facilitates comparing Dutch and international research data.
Martinez-Vega, Ingrid Patricia; Doubova, Svetlana V; Aguirre-Hernandez, Rebeca; Infante-Castañeda, Claudia
2016-03-02
The aim of this study was to adapt and validate the Distress Scale for Mexican patients with type 2 diabetes and hypertension (DSDH17M). Two family medicine clinics affiliated with the Mexican Institute of Social Security. 722 patients with type 2 diabetes and/or hypertension (235 patients with diabetes, 233 patients with hypertension and 254 patients with both diseases). A cross-sectional survey. The validation procedures included: (1) content validity using a group of experts, (2) construct validity from exploratory factor analysis, (3) internal consistency using Cronbach's α, (4) convergent validity between DSDH17M and anxiety and depression using the Spearman correlation coefficient, (5) discriminative validity through the Wilcoxon rank-sum test and (6) test-retest reliability using intraclass correlation coefficient. The DSDH17M has 17 items and three factors explaining 67% of the total variance. Cronbach α ranged from 0.83 to 0.91 among factors. The first factor of 'Regime-related Distress and Emotional Burden' moderately correlated with anxiety and depression scores. Discriminative validity revealed that patients with obesity, those with stressful events and those who did not adhere to pharmacological treatment had significantly higher distress scores in all DSDH17M domains. Test-retest intraclass correlation coefficient for DSDH17M ranged from 0.92 to 0.97 among factors. DSDH17M is a valid and reliable tool to identify distress of patients with type 2 diabetes and hypertension. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Validity Tests of the Adolescent Domain Screening Inventory (ADSI) with Older Adolescents
ERIC Educational Resources Information Center
Corrigan, Matthew J.; Forte, James; Bulgaris, Sarah
2017-01-01
The purpose of this replication study is to test the validity of the Adolescent Domain Screening Inventory (ADSI) on an older adolescent population. This cross sectional study used a convenience sample to preliminarily test the validity of the ADSI. Concurrent validity correlations ranged from a high of 0.924 to a low of 0.760. The known…
Aziz, M M; Galal, M A A; Elzohri, M H; El-Nouby, F; Leong, K P
2018-04-01
Systemic lupus erythematosus (SLE) is a chronic autoimmune disease which affects all aspects of quality of life (QoL) of the patients. Comprehensive patient assessment should include QoL measures in addition to the objective clinical measures of the disease. There is no specific Arabic instrument for assessment of QoL of SLE patients. The objective of this study was to translate and cross culturally adapt the SLEQOL questionnaire into Arabic and test its reliability and validity. The SLEQOL questionnaire was translated into Arabic based on the Guidelines for Translation and Cross-cultural Adaptation into other languages. Reliability was assessed by interviewing patients three times: two interviews on the same day by different interviewers and the third interview 14 days later by one of the first interviewers. Validity was assessed by correlating SLEQOL scores of 91 patients with 36-item Short Form Health Survey (SF-36) scores and clinical parameters of the patients. We found that the Arabic version of SLEQOL has a Cronbach's alpha of 0.936, interobserver and intraobserver correlation coefficients of 0.809 and 0.886 respectively. Strong correlations were also found between SLEQOL scores and SF-36 Physical and Mental Component summaries. In conclusion, the Arabic version of SLEQOL is a reliable and valid instrument for measuring QoL of Egyptian SLE patients.
Lee, Joo-Yup; Lim, Jae-Young; Oh, Joo Han; Ko, Young-Mi
2008-01-01
We developed a Korean version of the disabilities of arm, shoulder, and hand outcome questionnaire (K-DASH) by performing cross-cultural adaptation and evaluated the reliability and validity of the K-DASH. The K-DASH, SF-36, and Visual Analog Scale (VAS) for pain were administered to 161 patients with arm, shoulder, and hand problems. The internal consistency of the disability/symptom scores of the K-DASH was high (Cronbach's alpha 0.94). The retest assessed 131 of the 161 patients. The intraclass correlation coefficient was 0.91. The construct validity was evaluated using the correlations between the K-DASH and the SF-36 and VAS. The physical and mental component summary scales of the SF-36 and the VAS at rest and during activity were significantly correlated with the DASH disability/symptom scores. Despite the linguistic and cultural differences, the reliability and validity of the K-DASH were just as excellent as those of the original DASH.
Shafeei, Asrin; Mokhtarinia, Hamid Reza; Maleki-Ghahfarokhi, Azam; Piri, Leila
2017-08-01
Observational study. To cross-culturally translate the Orebro Musculoskeletal Pain Screening Questionnaire (OMPQ) into Persian and then evaluate its psychometric properties (reliability, validity, ceiling, and flooring effects). To the authors' knowledge, prior to this study there has been no validated instrument to screen the risk of chronicity in Persian-speaking patients with low back pain (LBP) in Iran. The OMPQ was specifically developed as a self-administered screening tool for assessing the risk of LBP chronicity. The forward-backward translation method was used for the translation and cross-cultural adaptation of the original questionnaire. In total, 202 patients with subacute LBP completed the OMPQ and the pain disability questionnaire (PDQ), which was used to assess convergent validity. 62 patients completed the OMPQ a week later as a retest. Slight changes were made to the OMPQ during the translation/cultural adaptation process; face validity of the Persian version was obtained. The Persian OMPQ showed excellent test-retest reliability (intraclass correlation coefficient=0.89). Its internal consistency was 0.71, and its convergent validity was confirmed by good correlation coefficient between the OMPQ and PDQ total scores ( r =0.72, p <0.05). No ceiling or floor effects were observed. The Persian version of the OMPQ is acceptable for the target society in terms of face validity, construct validity, reliability, and consistency. It is therefore considered a useful instrument for screening Iranian patients with LBP.
Cao, Shiqi; Liu, Ning; Han, Wuxiang; Zi, Yunpeng; Peng, Fan; Li, Lexiang; Fu, Qiwei; Chen, Yi; Zheng, Weijie; Qian, Qirong
2017-01-14
The Forgotten Joint Score (FJS) is a newly developed health-related quality of life (HRQoL) questionnaire designed to evaluate the awareness after total knee arthroplasty (TKA). This study cross-culturally adapted and psychometrically validated a simplified Chinese version of the FJS (SC-FJS). Cross-cultural adaptation was performed according to the internationally recognized guidelines. One-hundred and fifty participants who underwent primary TKA were recruited in this study. Cronbach's α and intra-class correlations were used to determine reliability. Construct validity was analyzed by evaluating the correlations between SC-FJS and the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the short form (36) health survey (SF-36). Each of the 12 items was properly responded and correlated with the total items. SC-FJS had excellent reliability [Cronbach's α = 0.907, intra-class correlation coefficient (ICC) = 0.970, 95% CI 0.959-0.978). Elimination of any one item in all did not result in a value of Cronbach's α of <0.80. SC-FJS had a high correlation with symptoms (0.67, p < 0.001) and pain (0.60, p < 0.001) domains of KOOS and social functioning (0.66, p < 0.001) domain of SF-36, and it also moderately correlated with function in daily living (0.53, p < 0.001) and function in sport and recreation (0.40, p < 0.001) domains of KOOS, and physical subscale of SF-36 (0.49-0.53, p < 0.001) but had a low (r = 0.20) or not significant (p > 0.05) correlation with mental subscale of SF-36. SC-FJS demonstrated excellent acceptability, internal consistency, reliability, and construct validity, which can be recommended for patients who underwent joint arthroplasty in Mainland China.
Küçükdeveci, Ayse A; Sahin, Hülya; Ataman, Sebnem; Griffiths, Bridget; Tennant, Alan
2004-02-15
Guidelines have been established for cross-cultural adaptation of outcome measures. However, invariance across cultures must also be demonstrated through analysis of Differential Item Functioning (DIF). This is tested in the context of a Turkish adaptation of the Health Assessment Questionnaire (HAQ). Internal construct validity of the adapted HAQ is assessed by Rasch analysis; reliability, by internal consistency and the intraclass correlation coefficient; external construct validity, by association with impairments and American College of Rheumatology functional stages. Cross-cultural validity is tested through DIF by comparison with data from the UK version of the HAQ. The adapted version of the HAQ demonstrated good internal construct validity through fit of the data to the Rasch model (mean item fit 0.205; SD 0.998). Reliability was excellent (alpha = 0.97) and external construct validity was confirmed by expected associations. DIF for culture was found in only 1 item. Cross-cultural validity was found to be sufficient for use in international studies between the UK and Turkey. Future adaptation of instruments should include analysis of DIF at the field testing stage in the adaptation process.
Bucci, Rosaria; Rongo, Roberto; Zito, Eugenio; Galeotti, Angela; Valletta, Rosa; D'Antò, Vincenzo
2015-03-01
To validate and cross-culturally adapt the Italian version of the Psychological Impact of Dental Aesthetics Questionnaire (PIDAQ) among Italian young adults. After translation, back translation, and cross-cultural adaptation of the English PIDAQ, a first version of the Italian questionnaire was pretested. The final Italian PIDAQ was administered to 598 subjects aged 18-30 years, along with two other instruments: the aesthetic component of the index of orthodontic treatment need (IOTN-AC) and the perception of occlusion scale (POS), which identified the self-reporting grade of malocclusion. Structural validity was assessed by means of factorial analysis, internal consistency was measured with Cronbach's alpha coefficient (α), convergent validity was assessed by means of Spearman correlation, and test-retest reliability was calculated with intra-class correlation coefficient (ICC) and standard measurement error. Criterion validity was evaluated by multivariate and univariate analysis of variance with Bonferroni post hoc tests. The α of the Italian PIDAQ domains ranged between 0.79 and 0.92. The ICC was between 0.81 and 0.90. The mean scores of each PIDAQ domain showed a statistically significant difference when analysed according to the IOTN-AC and POS scores. The satisfactory psychometric properties make PIDAQ a usable tool for future studies on oral health-related quality of life among Italian young adults.
Cross-cultural adaptation and validation of the Korean version of the Oxford shoulder score.
Roh, Young Hak; Noh, Jung Ho; Kim, Woo; Oh, Joo Han; Gong, Hyun Sik; Baek, Goo Hyun
2012-01-01
The Oxford shoulder score (OSS) is being used increasingly and has been adapted cross-culturally in some Western countries. On the other hand, there are few validated translations of the OSS in Asian countries. This study translated and adapted cross-culturally the original OSS to produce a Korean version, and assessed the validity and reliability of the Korean version of the OSS (Korean OSS). One hundred and five patients with shoulder pain caused by degenerative or inflammatory disorders completed the Korean OSS and Korean disability of arm, shoulder and hand (DASH). In addition, the pain score by a visual analog scale (VAS) during activity and at rest, subjective assessment of activities of daily living (ADL), the active range of motion (ROM), and measurements of the abduction strength (strength) were included in the validation process. There were no major linguistic or cultural problems during the forward and backward translations of the MHQ, except for a minor change due to cultural discrepancies in eating such as using a spoon and chopsticks by one dominant hand instead of a knife and fork by two hands. The internal consistency was high (Cronbach's alpha 0.91). The reproducibility test showed no significant difference (Intra-class coefficient 0.95). The construct validity, which was tested by the Pearson correlation coefficient revealed a strong correlation (r > 0.6) between the Korean OSS against subscale of DASH disability/symptom, DASH work and ADL, as well as a moderate correlation (0.3 < r < 0.6) with the DASH sports/music, strength, ROM, pain during activity and pain at rest. The Korean OSS proved to be valid by demonstrating a significant correlation with the patient-based upper extremity questionnaire and clinical assessment. The application and evaluation of the instrument is feasible and understandable among patients in Korea.
He, S L; Wang, J H; Ji, P
2018-03-01
To validate the Pain Resilience Scale (PRS) for use in Chinese patients with temporomandibular disorders (TMD) pain. According to international guidelines, the original PRS was first translated and cross-culturally adapted to formulate the Chinese version of PRS (PRS-C). A total of 152 patients with TMD pain were recruited to complete series of questionnaires. Reliability of the PRS-C was investigated using internal consistency and test-retest reliability. Validity of the PRS-C was calculated using cross-cultural validity and convergent validity. Cross-cultural validity was evaluated by examining the confirmatory factor analysis (CFA). And convergent validity was examined through correlating the PRS-C scores with scores of 2 commonly used pain-related measures (the Connor-Davidson Resilience Scale [CD-RISC] and the Tampa Scale for Kinesiophobia for Temporomandibular Disorders [TSK-TMD]). The PRS-C had a high internal consistency (Cronbach's alpha = 0.92) and good test-retest reliability (intra-class correlation coefficient [ICC] = 0.81). The CFA supported a 2-factor model for the PRS-C with acceptable fit to the data. The fit indices were chi-square/DF = 2.21, GFI = 0.91, TLI = 0.97, CFI = 0.98 and RMSEA = 0.08. As regards convergent validity, the PRS-C evidenced moderate-to-good relationships with the CD-RISC and the TSK-TMD. The PRS-C shows good psychometric properties and could be considered as a reliable and valid measure to evaluate pain-related resilience in patients with TMD pain. © 2017 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Kitterød, Nils-Otto
2017-08-01
Unconsolidated sediment cover thickness (D) above bedrock was estimated by using a publicly available well database from Norway, GRANADA. General challenges associated with such databases typically involve clustering and bias. However, if information about the horizontal distance to the nearest bedrock outcrop (L) is included, does the spatial estimation of D improve? This idea was tested by comparing two cross-validation results: ordinary kriging (OK) where L was disregarded; and co-kriging (CK) where cross-covariance between D and L was included. The analysis showed only minor differences between OK and CK with respect to differences between estimation and true values. However, the CK results gave in general less estimation variance compared to the OK results. All observations were declustered and transformed to standard normal probability density functions before estimation and back-transformed for the cross-validation analysis. The semivariogram analysis gave correlation lengths for D and L of approx. 10 and 6 km. These correlations reduce the estimation variance in the cross-validation analysis because more than 50 % of the data material had two or more observations within a radius of 5 km. The small-scale variance of D, however, was about 50 % of the total variance, which gave an accuracy of less than 60 % for most of the cross-validation cases. Despite the noisy character of the observations, the analysis demonstrated that L can be used as secondary information to reduce the estimation variance of D.
Zambelli, Roberto; Pinto, Rafael Z; Magalhães, João Murilo Brandão; Lopes, Fernando Araujo Silva; Castilho, Rodrigo Simões; Baumfeld, Daniel; Dos Santos, Thiago Ribeiro Teles; Maffulli, Nicola
2016-01-01
There is a need for a patient-relevant instrument to evaluate outcome after treatment in patients with a total Achilles tendon rupture. The purpose of this study was to undertake a cross-cultural adaptation of the Achilles Tendon Total Rupture Score (ATRS) into Brazilian Portuguese, determining the test-retest reliability and construct validity of the instrument. A five-step approach was used in the cross-cultural adaptation process: initial translation (two bilingual Brazilian translators), synthesis of translation, back-translation (two native English language translators), consensus version and evaluation (expert committee), and testing phase. A total of 46 patients were recruited to evaluate the test-retest reproducibility and construct validity of the Brazilian Portuguese version of the ATRS. Test-retest reproducibility was performed by assessing each participant on two separate occasions. The construct validity was determined by the correlation index between the ATRS and the Orthopedic American Foot and Ankle Society (AOFAS) questionnaires. The final version of the Brazilian Portuguese ATRS had the same number of questions as the original ATRS. For the reliability analysis, an ICC(2,1) of 0.93 (95 % CI: 0.88 to 0.96) with SEM of 1.56 points and MDC of 4.32 was observed, indicating excellent reliability. The construct validity showed excellent correlation with R = 0.76 (95 % CI: 0.52 to 0.89, P < 0.001). The ATRS was successfully cross-culturally validated into Brazilian Portuguese. This version was a reliable and valid measure of function in patients who suffered complete rupture of the Achilles Tendon.
A Simple Model to Identify Risk of Sarcopenia and Physical Disability in HIV-Infected Patients.
Farinatti, Paulo; Paes, Lorena; Harris, Elizabeth A; Lopes, Gabriella O; Borges, Juliana P
2017-09-01
Farinatti, P, Paes, L, Harris, EA, Lopes, GO, and Borges, JP. A simple model to identify risk of sarcopenia and physical disability in HIV-infected patients. J Strength Cond Res 31(9): 2542-2551, 2017-Early detection of sarcopenia might help preventing muscle loss and disability in HIV-infected patients. This study proposed a model for estimating appendicular skeletal muscle mass (ASM) to calculate indices to identify "sarcopenia" (SA) and "risk for disability due to sarcopenia" (RSA) in patients with HIV. An equation to estimate ASM was developed in 56 patients (47.2 ± 6.9 years), with a cross-validation sample of 24 patients (48.1 ± 6.6 years). The model validity was determined by calculating, in both samples: (a) Concordance between actual vs. estimated ASM; (b) Correlations between actual/estimated ASM vs. peak torque (PT) and total work (TW) during isokinetic knee extension/flexion; (c) Agreement of patients classified with SA and RSA. The predictive equation was ASM (kg) = 7.77 (sex; F = 0/M = 1) + 0.26 (arm circumference; cm) + 0.38 (thigh circumference; cm) + 0.03 (Body Mass Index; kg·m) - 8.94 (R = 0.74; Radj = 0.72; SEE = 3.13 kg). Agreement between actual vs. estimated ASM was confirmed in validation (t = 0.081/p = 0.94; R = 0.86/p < 0.0001) and cross-validation (t = 0.12/p = 0.92; R = 0.87/p < 0.0001) samples. Regression characteristics in cross-validation sample (Radj = 0.80; SEE = 3.65) and PRESS (RPRESS = 0.69; SEEPRESS = 3.35) were compatible with the original model. Percent agreements for the classification of SA and RSA from indices calculated using actual and estimated ASM were of 87.5% and 77.2% (gamma correlations 0.72-1.0; p < 0.04) in validation, and 95.8% and 75.0% (gamma correlations 0.98-0.97; p < 0.001) in cross-validation sample, respectively. Correlations between actual/estimated ASM vs. PT (range 0.50-0.73, p ≤ 0.05) and TW (range 0.59-0.74, p ≤ 0.05) were similar in both samples. In conclusion, our model correctly estimated ASM to determine indices for identifying SA and RSA in HIV-infected patients.
Kim, Kyoung-Eun; Lim, Jae-Young
2011-01-01
The Roland-Morris Disability Questionnaire (RMDQ) is a reliable tool for evaluating disability in patients with back pain, but no Korean version has been published and validated. We developed a cross-culturally adapted Korean version of the RMDQ (RMDQ-K) and validated its use for assessing disability in Korean patients with low back pain. Two hundred thirty-one patients with low back pain were assessed using the RMDQ-K, visual analog scale (VAS) during rest and activity, and the Oswestry Disability Index (ODI). The results of 40 patients were used to evaluate the test-retest reliability. The correlations of the RMDQ-K with the VAS and ODI were used to assess validity. The reliability of the RMDQ-K estimated using the internal consistency reached a Cronbach's alpha of 0.893. Test-retest trials showed a high intraclass correlation coefficient of 0.837 (95% CI 0.833-0.953). The RMDQ-K was significantly correlated with the ODI (r=0.738) and VAS during rest (r=0.450) and activity (r=0.412). This study demonstrates that the RMDQ-K is a reliable, valid instrument for measuring of disability in Korean patients with low back pain.
Hamamoto, Yosuke; Ito, Hiromu; Furu, Moritoshi; Ishikawa, Masahiro; Azukizawa, Masayuki; Kuriyama, Shinichi; Nakamura, Shinichiro; Matsuda, Shuichi
2015-09-01
The purposes of this study were to translate the new Knee Society Score (KSS) into Japanese and to evaluate the construct and content validity, test-retest reliability, and internal consistency of the Japanese version of the new KSS. The Japanese version of the KSS was developed according to cross-cultural guidelines by using the "translation-back translation" method to ensure content validity. KSS data were then obtained from patients who had undergone total knee arthroplasty (TKA). The psychometric properties evaluated were as follows: for feasibility, response rate, and floor and ceiling effects; for construct validity, internal consistency using Cronbach's alpha, and correlations with quality of life. Construct validity was evaluated by using Spearman's correlation coefficient to quantify the correlation between the KSS and the Japanese version of the Oxford 12-item Knee Score or Short Form 36 Health Survey (SF-36) questionnaires. The Japanese version of the KSS was sent to 93 consecutive osteoarthritic patients who underwent primary TKA in our institution. Fifty-five patients completed the questionnaires and were included in this study. Neither a floor nor ceiling effect was observed. The reliability proved excellent in the majority of domains, with intraclass correlation coefficients of 0.65-0.88. Internal consistency, assessed by Cronbach's alpha, was good to excellent for all domains (0.78-0.94). All of the four domains of the KSS correlated significantly with the Oxford 12-item Knee Score. The activity and satisfaction domains of the KSS correlated significantly with all and the majority of subscales of the SF-36, respectively, whereas symptoms and expectation domains showed significant correlations only with bodily pain and vitality subscales and with the physical function, bodily pain, and vitality subscales, respectively. The Japanese version of the new KSS is a valid, reliable, and responsive instrument to capture subjective aspects of the functional symptoms and abilities of patients who undergo TKA.
Ramos, Tatiana Dalpasquale; Brito, Maria José Azevedo de; Piccolo, Mônica Sarto; Rosella, Maria Fernanda Normanha da Silva Martins; Sabino, Miguel; Ferreira, Lydia Masako
2016-07-21
Rhinoplasty is one of the most sought-after esthetic operations among individuals with body dysmorphic disorder. The aim of this study was to cross-culturally adapt and validate the Body Dysmorphic Symptoms Scale. Cross-cultural validation study conducted in a plastic surgery outpatient clinic of a public university hospital. Between February 2014 and March 2015, 80 consecutive patients of both sexes seeking rhinoplasty were selected. Thirty of them participated in the phase of cultural adaptation of the instrument. Reproducibility was tested on 20 patients and construct validity was assessed on 50 patients, with correlation against the Yale-Brown Obsessive Compulsive Scale for Body Dysmorphic Disorder. The Brazilian version of the instrument showed Cronbach's alpha of 0.805 and excellent inter-rater reproducibility (intraclass correlation coefficient, ICC = 0.873; P < 0.001) and intra-rater reproducibility (ICC = 0.939; P < 0.001). Significant differences in total scores were found between patients with and without symptoms (P < 0.001). A strong correlation (r = 0.841; P < 0.001) was observed between the Yale-Brown Obsessive Compulsive Scale for Body Dysmorphic Disorder and the Body Dysmorphic Symptoms Scale. The area under the receiver operating characteristic curve was 0.981, thus showing good accuracy for discriminating between presence and absence of symptoms of body dysmorphic disorder. Forty-six percent of the patients had body dysmorphic symptoms and 54% had moderate to severe appearance-related obsessive-compulsive symptoms. The Brazilian version of the Body Dysmorphic Symptoms Scale is a reproducible instrument that presents face, content and construct validity.
Ramos, Tatiana Dalpasquale; Brito, Maria José Azevedo de; Piccolo, Mônica Sarto; Rosella, Maria Fernanda Normanha da Silva Martins; Sabino, Miguel; Ferreira, Lydia Masako
2016-01-01
Rhinoplasty is one of the most sought-after esthetic operations among individuals with body dysmorphic disorder. The aim of this study was to cross-culturally adapt and validate the Body Dysmorphic Symptoms Scale. Cross-cultural validation study conducted in a plastic surgery outpatient clinic of a public university hospital. Between February 2014 and March 2015, 80 consecutive patients of both sexes seeking rhinoplasty were selected. Thirty of them participated in the phase of cultural adaptation of the instrument. Reproducibility was tested on 20 patients and construct validity was assessed on 50 patients, with correlation against the Yale-Brown Obsessive Compulsive Scale for Body Dysmorphic Disorder. The Brazilian version of the instrument showed Cronbach's alpha of 0.805 and excellent inter-rater reproducibility (intraclass correlation coefficient, ICC = 0.873; P < 0.001) and intra-rater reproducibility (ICC = 0.939; P < 0.001). Significant differences in total scores were found between patients with and without symptoms (P < 0.001). A strong correlation (r = 0.841; P < 0.001) was observed between the Yale-Brown Obsessive Compulsive Scale for Body Dysmorphic Disorder and the Body Dysmorphic Symptoms Scale. The area under the receiver operating characteristic curve was 0.981, thus showing good accuracy for discriminating between presence and absence of symptoms of body dysmorphic disorder. Forty-six percent of the patients had body dysmorphic symptoms and 54% had moderate to severe appearance-related obsessive-compulsive symptoms. The Brazilian version of the Body Dysmorphic Symptoms Scale is a reproducible instrument that presents face, content and construct validity.
Cross-validation of the Beunen-Malina method to predict adult height.
Beunen, Gaston P; Malina, Robert M; Freitas, Duarte I; Maia, José A; Claessens, Albrecht L; Gouveia, Elvio R; Lefevre, Johan
2010-08-01
The purpose of this study was to cross-validate the Beunen-Malina method for non-invasive prediction of adult height. Three hundred and eight boys aged 13, 14, 15 and 16 years from the Madeira Growth Study were observed at annual intervals in 1996, 1997 and 1998 and re-measured 7-8 years later. Height, sitting height and the triceps and subscapular skinfolds were measured; skeletal age was assessed using the Tanner-Whitehouse 2 method. Adult height was measured and predicted using the Beunen-Malina method. Maturity groups were classified using relative skeletal age (skeletal age minus chronological age). Pearson correlations, mean differences and standard errors of estimate (SEE) were calculated. Age-specific correlations between predicted and measured adult height vary between 0.70 and 0.85, while age-specific SEE varies between 3.3 and 4.7 cm. The correlations and SEE are similar to those obtained in the development of the original Beunen-Malina method. The Beunen-Malina method is a valid method to predict adult height in adolescent boys and can be used in European populations or populations from European ancestry. Percentage of predicted adult height is a non-invasive valid method to assess biological maturity.
Translation and validation of a Spanish version of the xerostomia inventory.
Serrano, Carlos; Fariña, María P; Pérez, Cristhian; Fernández, Marcos; Forman, Katherine; Carrasco, Mauricio
2016-12-01
The aim of this study was to validate a Spanish cross-cultural adaptation of the xerostomia inventory (XI). The original English version of XI was translated into Spanish, cross-culturally adapted and field tested. The Spanish version of XI (XI-Sp) was tested with a sample of 41 patients with xerostomia. The reliability of the XI-Sp was determined through internal consistency and test-retest methods. The construct validity of XI-Sp was determined by means of correlation between XI-Sp scores and salivary flow measurements. Overall XI-Sp scores were 40.8 (SD = 10) for the first application and 40.2 (SD = 9.5) for the second. Cronbach's alpha value for the XI-Sp was 0.89 and 0.87, respectively, while interitem correlation averages were r = 0.44 and r = 0.39 for each application. Interitem correlation and corrected total was r c ≥0.30. The test-retest intraclass correlation coefficient value for the XI-Sp score was 0.59 and 0.91. Convergent validity for construct validity correlation with salivary flow showed a medium effect size (r 2 = 0.10) for the first application but did not make a statistically significant prediction for the second (r 2 = 0.7). This study provides evidence concerning the reliability of the XI-Sp, showing that it may be a useful tool for Spanish-speaking xerostomia patients for both clinical and epidemiologic research. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.
2D-QSAR and 3D-QSAR Analyses for EGFR Inhibitors
Zhao, Manman; Zheng, Linfeng; Qiu, Chun
2017-01-01
Epidermal growth factor receptor (EGFR) is an important target for cancer therapy. In this study, EGFR inhibitors were investigated to build a two-dimensional quantitative structure-activity relationship (2D-QSAR) model and a three-dimensional quantitative structure-activity relationship (3D-QSAR) model. In the 2D-QSAR model, the support vector machine (SVM) classifier combined with the feature selection method was applied to predict whether a compound was an EGFR inhibitor. As a result, the prediction accuracy of the 2D-QSAR model was 98.99% by using tenfold cross-validation test and 97.67% by using independent set test. Then, in the 3D-QSAR model, the model with q2 = 0.565 (cross-validated correlation coefficient) and r2 = 0.888 (non-cross-validated correlation coefficient) was built to predict the activity of EGFR inhibitors. The mean absolute error (MAE) of the training set and test set was 0.308 log units and 0.526 log units, respectively. In addition, molecular docking was also employed to investigate the interaction between EGFR inhibitors and EGFR. PMID:28630865
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Chi; Martin, Yves; Khater, Marwan
2017-05-15
We present a phenomenological model correlating optical return loss and amplitude of fringes in transmission spectrum due to distributed backscattering in high-index-contrast waveguides. The model is validated experimentally using four different waveguide cross sections.
Estimating monthly streamflow values by cokriging
Solow, A.R.; Gorelick, S.M.
1986-01-01
Cokriging is applied to estimation of missing monthly streamflow values in three records from gaging stations in west central Virginia. Missing values are estimated from optimal consideration of the pattern of auto- and cross-correlation among standardized residual log-flow records. Investigation of the sensitivity of estimation to data configuration showed that when observations are available within two months of a missing value, estimation is improved by accounting for correlation. Concurrent and lag-one observations tend to screen the influence of other available observations. Three models of covariance structure in residual log-flow records are compared using cross-validation. Models differ in how much monthly variation they allow in covariance. Precision of estimation, reflected in mean squared error (MSE), proved to be insensitive to this choice. Cross-validation is suggested as a tool for choosing an inverse transformation when an initial nonlinear transformation is applied to flow values. ?? 1986 Plenum Publishing Corporation.
Temporal cross-correlation asymmetry and departure from equilibrium in a bistable chemical system.
Bianca, C; Lemarchand, A
2014-06-14
This paper aims at determining sustained reaction fluxes in a nonlinear chemical system driven in a nonequilibrium steady state. The method relies on the computation of cross-correlation functions for the internal fluctuations of chemical species concentrations. By employing Langevin-type equations, we derive approximate analytical formulas for the cross-correlation functions associated with nonlinear dynamics. Kinetic Monte Carlo simulations of the chemical master equation are performed in order to check the validity of the Langevin equations for a bistable chemical system. The two approaches are found in excellent agreement, except for critical parameter values where the bifurcation between monostability and bistability occurs. From the theoretical point of view, the results imply that the behavior of cross-correlation functions cannot be exploited to measure sustained reaction fluxes in a specific nonlinear system without the prior knowledge of the associated chemical mechanism and the rate constants.
Freitas, N O; Forero, C G; Alonso, J; Caltran, M P; Dantas, R A S; Farina, J A; Rossi, L A
2017-01-01
Burn patients may encounter social barriers and stigmatization. The objectives of this study were to adapt the Social Comfort Questionnaire (SCQ) into Brazilian Portuguese and to assess the psychometric properties of the adapted version. Cross-cultural adaptation of the 8 items of the SCQ followed international guidelines. We interviewed 240 burn patients and verified the SCQ internal consistency, test-retest reliability and construct validity, correlating the scores with depression [Beck Depression Inventory (BDI)], affect/body image and interpersonal relationships [Burns Specific Health Scale-Revised (BSHS-R)] and self-esteem [Rosenberg's Self-Esteem Scale (RSES)]. We also performed a confirmatory factor analysis (CFA). The cross-cultural adaptation resulted in minor semantic modifications to the original SCQ version. After CFA, a reduced 6-item version showed satisfactory fit to the one-factor model (RMSEA = 0.05, CFI = 0.99, TLI = 0.99). Cronbach alpha's was 0.80, and test-retest intraclass correlation coefficient was 0.86. The final version presented a strong negative correlation with depression (BDI), and strong positive correlations with affect/body image (BSHS-R), interpersonal relationships (BSHS-R) and self-esteem (RSES) (all p < 0.001). The results showed that the SCQ Brazilian Portuguese adapted version complies with the validity and reliability criteria required for an instrument assessing social comfort in Brazilian burn patients. The Brazilian version yields a single score that is easy to interpret and well understood by patients.
K-Fold Crossvalidation in Canonical Analysis.
ERIC Educational Resources Information Center
Liang, Kun-Hsia; And Others
1995-01-01
A computer-assisted, K-fold cross-validation technique is discussed in the framework of canonical correlation analysis of randomly generated data sets. Analysis results suggest that this technique can effectively reduce the contamination of canonical variates and canonical correlations by sample-specific variance components. (Author/SLD)
The cross-cultural adaptation of the DASH questionnaire in Thai (DASH-TH).
Tongprasert, Siam; Rapipong, Jeeranan; Buntragulpoontawee, Montana
2014-01-01
Clinical measurement. Currently there are no self-report questionnaires in Thai to evaluate disability levels in patients suffering from upper extremity musculoskeletal disorders. To translate and cross-cultural adaptation the disabilities of the arm, shoulder and hand (DASH) questionnaire to Thai version and to evaluate content validity, construct validity and internal consistency of the questionnaire. The DASH-TH was produced by following cross-cultural adaptation guidelines stated by the Institute for Work and Health (IWH). Forty Thai patients with arm, shoulder or hand problems participated in field testing of the questionnaire. Content validity was determined by obtaining the item-objective congruence (IOC) value for each questionnaire item. Correlation between the DASH-TH score and numeric rating scale was used to assess construct validity. Internal consistency of DASH-TH was measured using Cronbach's alpha coefficient. Forty patients (14 males, 26 females) with arm, shoulder or hand problems enrolled in the present study. The average age of patients was 44.8 years. The index of item-objective congruence (IOC) of each item ranged from 0.7 to 1.0. The Cronbach's alpha coefficient of the questionnaire was 0.938. There was no correlation between DASH-TH score and numeric rating scale. The DASH-TH has high content validity and internal consistency. N/A. Copyright © 2014 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xiaolin; Ye, Li; Wang, Xiaoxiang
2012-12-15
Several recent reports suggested that hydroxylated polybrominated diphenyl ethers (HO-PBDEs) may disturb thyroid hormone homeostasis. To illuminate the structural features for thyroid hormone activity of HO-PBDEs and the binding mode between HO-PBDEs and thyroid hormone receptor (TR), the hormone activity of a series of HO-PBDEs to thyroid receptors β was studied based on the combination of 3D-QSAR, molecular docking, and molecular dynamics (MD) methods. The ligand- and receptor-based 3D-QSAR models were obtained using Comparative Molecular Similarity Index Analysis (CoMSIA) method. The optimum CoMSIA model with region focusing yielded satisfactory statistical results: leave-one-out cross-validation correlation coefficient (q{sup 2}) was 0.571 andmore » non-cross-validation correlation coefficient (r{sup 2}) was 0.951. Furthermore, the results of internal validation such as bootstrapping, leave-many-out cross-validation, and progressive scrambling as well as external validation indicated the rationality and good predictive ability of the best model. In addition, molecular docking elucidated the conformations of compounds and key amino acid residues at the docking pocket, MD simulation further determined the binding process and validated the rationality of docking results. -- Highlights: ► The thyroid hormone activities of HO-PBDEs were studied by 3D-QSAR. ► The binding modes between HO-PBDEs and TRβ were explored. ► 3D-QSAR, molecular docking, and molecular dynamics (MD) methods were performed.« less
Baldwin, Carol M; Choi, Myunghan; McClain, Darya Bonds; Celaya, Alma; Quan, Stuart F
2012-04-15
To translate, back-translate and cross-language validate (English/Spanish) the Sleep Heart Health Study Sleep Habits Questionnaire for use with Spanish-speakers in clinical and research settings. Following rigorous translation and back-translation, this cross-sectional cross-language validation study recruited bilingual participants from academic, clinic, and community-based settings (N = 50; 52% women; mean age 38.8 ± 12 years; 90% of Mexican heritage). Participants completed English and Spanish versions of the Sleep Habits Questionnaire, the Epworth Sleepiness Scale, and the Acculturation Rating Scale for Mexican Americans II one week apart in randomized order. Psychometric properties were assessed, including internal consistency, convergent validity, scale equivalence, language version intercorrelations, and exploratory factor analysis using PASW (Version18) software. Grade level readability of the sleep measure was evaluated. All sleep categories (duration, snoring, apnea, insomnia symptoms, other sleep symptoms, sleep disruptors, restless legs syndrome) showed Cronbach α, Spearman-Brown coefficients and intercorrelations ≥ 0.700, suggesting robust internal consistency, correlation, and agreement between language versions. The Epworth correlated significantly with snoring, apnea, sleep symptoms, restless legs, and sleep disruptors) on both versions, supporting convergent validity. Items loaded on 4 factors accounted for 68% and 67% of the variance on the English and Spanish versions, respectively. The Spanish-language Sleep Habits Questionnaire demonstrates conceptual and content equivalency. It has appropriate measurement properties and should be useful for assessing sleep health in community-based clinics and intervention studies among Spanish-speaking Mexican Americans. Both language versions showed readability at the fifth grade level. Further testing is needed with larger samples.
Baldwin, Carol M.; Choi, Myunghan; McClain, Darya Bonds; Celaya, Alma; Quan, Stuart F.
2012-01-01
Study Objectives: To translate, back-translate and cross-language validate (English/Spanish) the Sleep Heart Health Study Sleep Habits Questionnaire for use with Spanish-speakers in clinical and research settings. Methods: Following rigorous translation and back-translation, this cross-sectional cross-language validation study recruited bilingual participants from academic, clinic, and community-based settings (N = 50; 52% women; mean age 38.8 ± 12 years; 90% of Mexican heritage). Participants completed English and Spanish versions of the Sleep Habits Questionnaire, the Epworth Sleepiness Scale, and the Acculturation Rating Scale for Mexican Americans II one week apart in randomized order. Psychometric properties were assessed, including internal consistency, convergent validity, scale equivalence, language version intercorrelations, and exploratory factor analysis using PASW (Version18) software. Grade level readability of the sleep measure was evaluated. Results: All sleep categories (duration, snoring, apnea, insomnia symptoms, other sleep symptoms, sleep disruptors, restless legs syndrome) showed Cronbach α, Spearman-Brown coefficients and intercorrelations ≥ 0.700, suggesting robust internal consistency, correlation, and agreement between language versions. The Epworth correlated significantly with snoring, apnea, sleep symptoms, restless legs, and sleep disruptors) on both versions, supporting convergent validity. Items loaded on 4 factors accounted for 68% and 67% of the variance on the English and Spanish versions, respectively. Conclusions: The Spanish-language Sleep Habits Questionnaire demonstrates conceptual and content equivalency. It has appropriate measurement properties and should be useful for assessing sleep health in community-based clinics and intervention studies among Spanish-speaking Mexican Americans. Both language versions showed readability at the fifth grade level. Further testing is needed with larger samples. Citation: Baldwin CM; Choi M; McClain DB; Celaya A; Quan SF. Spanish translation and cross-language validation of a Sleep Habits Questionnaire for use in clinical and research settings. J Clin Sleep Med 2012;8(2):137-146. PMID:22505858
Prediction of adult height in girls: the Beunen-Malina-Freitas method.
Beunen, Gaston P; Malina, Robert M; Freitas, Duarte L; Thomis, Martine A; Maia, José A; Claessens, Albrecht L; Gouveia, Elvio R; Maes, Hermine H; Lefevre, Johan
2011-12-01
The purpose of this study was to validate and cross-validate the Beunen-Malina-Freitas method for non-invasive prediction of adult height in girls. A sample of 420 girls aged 10-15 years from the Madeira Growth Study were measured at yearly intervals and then 8 years later. Anthropometric dimensions (lengths, breadths, circumferences, and skinfolds) were measured; skeletal age was assessed using the Tanner-Whitehouse 3 method and menarcheal status (present or absent) was recorded. Adult height was measured and predicted using stepwise, forward, and maximum R (2) regression techniques. Multiple correlations, mean differences, standard errors of prediction, and error boundaries were calculated. A sample of the Leuven Longitudinal Twin Study was used to cross-validate the regressions. Age-specific coefficients of determination (R (2)) between predicted and measured adult height varied between 0.57 and 0.96, while standard errors of prediction varied between 1.1 and 3.9 cm. The cross-validation confirmed the validity of the Beunen-Malina-Freitas method in girls aged 12-15 years, but at lower ages the cross-validation was less consistent. We conclude that the Beunen-Malina-Freitas method is valid for the prediction of adult height in girls aged 12-15 years. It is applicable to European populations or populations of European ancestry.
Validity and reliability of the Tibetan version of s-EMBU for measuring parenting styles.
Yangzong, Ciren; Lerkiatbundit, Sanguan; Luobu, Ouzhu; Cui, Chaoying; Liabsuetrakul, Tippawan; Kangzhuo, Baima; Quzong, Deji; Zhandui, Luobu; Zhen, Pu; Chongsuvivatwong, Virasakdi
2017-01-01
Parenting style experienced during childhood has profound effects on children's futures. Scales developed in other countries have never been validated in the Tibetan context. The present study aimed to examine the construct validity and reliability of a Tibetan translation of the 23-item short form of the Egna Minnen Beträffande Uppfostran [One's Memories of Upbringing] (s-EMBU) and to test the correlation between the parenting styles of fathers and mothers. A cross-sectional study was conducted in a sample of 847 students aged 12-21 years from Lhasa, Tibet, during September and October 2015 with a participation rate of 97.7%. The Tibetan translation of self-completed s-EMBU was administered. Confirmatory factor analysis was employed to test the scale's validity on the first half of the sample and was then cross-validated with the second half of the sample. The final model consisted of six factors: three (rejection, emotional warmth, and overprotection) for each parent, equality constrained on factor loadings, factor correlations, and error variance between father and mother. Father-mother correlation coefficients ranged from 0.81 to 0.86, and the level of consistency ranged from 0.62 to 0.82. Thus, the slightly modified s-EMBU is suitable for use in the Tibetan culture where both the father and the mother have consistent parenting styles.
Validity and reliability of the Tibetan version of s-EMBU for measuring parenting styles
Yangzong, Ciren; Lerkiatbundit, Sanguan; Luobu, Ouzhu; Cui, Chaoying; Liabsuetrakul, Tippawan; Kangzhuo, Baima; Quzong, Deji; Zhandui, Luobu; Zhen, Pu; Chongsuvivatwong, Virasakdi
2017-01-01
Parenting style experienced during childhood has profound effects on children’s futures. Scales developed in other countries have never been validated in the Tibetan context. The present study aimed to examine the construct validity and reliability of a Tibetan translation of the 23-item short form of the Egna Minnen Beträffande Uppfostran [One’s Memories of Upbringing] (s-EMBU) and to test the correlation between the parenting styles of fathers and mothers. A cross-sectional study was conducted in a sample of 847 students aged 12–21 years from Lhasa, Tibet, during September and October 2015 with a participation rate of 97.7%. The Tibetan translation of self-completed s-EMBU was administered. Confirmatory factor analysis was employed to test the scale’s validity on the first half of the sample and was then cross-validated with the second half of the sample. The final model consisted of six factors: three (rejection, emotional warmth, and overprotection) for each parent, equality constrained on factor loadings, factor correlations, and error variance between father and mother. Father–mother correlation coefficients ranged from 0.81 to 0.86, and the level of consistency ranged from 0.62 to 0.82. Thus, the slightly modified s-EMBU is suitable for use in the Tibetan culture where both the father and the mother have consistent parenting styles. PMID:28053560
Georgieva-Zhostova, Spaska; Kolev, Ognyan I; Stambolieva, Katerina
2014-09-01
The aim of the present study was the translation, cross-cultural adaptation and validation of the Dizziness Handicap Inventory in Bulgarian language (DHI-BG). Ninety-seven vestibular patients (19 men and 78 women, mean age 45.08 ± 13.85 years) took part in the investigation. All participants were asked to fill in the DHI-BG. Internal consistency was estimated using Cronbach's alpha and item-total correlation, reproducibility by calculating Bland-Altman's limits of agreement and intraclass correlation coefficients (ICCs). Associations were estimated by Spearman's correlation coefficients. The Cronbach's alpha for the total score, functional, physical and emotional subscales of DHI-BG were 0.88, 0.75, 0.72 and 0.81. The floor and ceiling effects of the DHI-BG total scale were evaluated with respect to the limits of agreement which were ±9.4-14.53 points. Intraclass correlation coefficients (ICCs) for all scale and subscales were higher than the recommended value of 0.75 and determined good test-retest reliability. The range of items correlation for DHI-BG was from 0.27 (item 12) to 0.72 (item 3). No significant differences were observed in the Cronbach's alpha coefficients between the DHI-BG and the original version, the German and Italian versions of the questionnaire. The most significant difference was observed in comparison with the German version of DHI. Construct validity presented a moderate correlation between Romberg coefficients and DHI-BG scores and strong correlation between all scores of DHI and the self-perceived disability. The results suggest that DHI-BG scores show a good discriminative validity between groups with different levels of self-assessed disability. The Bulgarian version of the DHI is a reliable and valid tool in assessing the impact of dizziness on the quality of life in Bulgarian vestibular patients.
Frauendorf, Renata; de Medeiros Pinheiro, Marcelo; Ciconelli, Rozana Mesquita
2014-12-01
Loss of productivity at work, as a result of health problems, is becoming an issue of interest due to the high burden it represents in society. The measurement of such phenomenon can be made using generic and specific scales for certain diseases such as the Stanford Presenteeism Scale (SPS-6) and the Work Instability Scale for Ankylosing Spondylitis (AS-WIS), specific for patients with ankylosing spondylitis (AS). The aim of this study was to translate and perform a cross-cultural adaptation of SPS-6 and AS-WIS into Portuguese and check their psychometric properties. The study also aimed to evaluate the relationship between the general scores of the scales and the main sociodemographic and clinical data, lifestyles, and absenteeism in patients with AS and correlate these variables with SPS-6 and AS-WIS scales. A sample of 120 patients with AS and 80 workers at a university hospital was evaluated. The processes for the translation and cross-cultural adaptation of the instruments followed preestablished steps and rules presented in the literature. For the evaluation of measurement properties and correlations between scales, intra-class correlation coefficient (reproducibility analysis), Cronbach alpha (internal consistency), and Pearson correlation coefficient (validity) were employed. The inter-observer (0.986) and intra-observer (0.992) reproducibilities of the AS-WIS were shown to be high as well as the internal consistency (0.995). Similarly, the inter-observer reliability of SPS-6 was considered good (0.890), although it showed a poorer performance when considering the same observer (Pearson correlation coefficient = 0.675 and intra-class correlation = 0.656). Internal consistency, for the total number of items, as measured by Cronbach alpha, was 0.889. The validity of the scales was evaluated thru the comparison of the achieved scores with the results of the WLQ, SF-36, ASQoL, BASFI, BASDAI, HAQ-S, and SRQ-20 instruments. Correlations between loss of productivity at work, worse quality of life, presence of emotional disturbances, and worse health conditions were positive. The process of translation, cross-cultural adaptation, and validation of the SPS-6 as a generic measurement for the loss of productivity at work and of the AS-WIS as a specific measurement for patients with AS are valid, reproducible, and specific instruments to be used in Brazil. In both scales, productivity at work was associated to advanced age, higher rate of absenteeism in the last month and year, presence of peripheral arthritis, and a larger number of comorbidities in patients with AS. The AS-WIS and SPS-6 showed a good correlation among them although they are not mutually exclusive but supplementary.
The African American Acculturation Scale II: Cross-Validation and Short Form.
ERIC Educational Resources Information Center
Landrine, Hope; Klonoff, Elizabeth A.
1995-01-01
Studied African American culture, using a new, shortened, 33-item African American Acculturation Scale (AAAS-33) to assess the scale's validity and reliability. Comparisons between the original form and AAAS-33 reveal high correlations, however, the longer form may be sensitive to some beliefs, practices, and attitudes not assessed by the short…
Saez de la Fuente, Javier; Such Diaz, Ana; Cañamares-Orbis, Irene; Ramila, Estela; Izquierdo-Garcia, Elsa; Esteban, Concepcion; Escobar-Rodríguez, Ismael
2016-11-01
The most widely used validated instrument to assess the complexity of medication regimens is the Medication Regimen Complexity Index (MRCI). This study aimed to translate, adapt, and validate a reliable version of the MRCI adapted to Spanish (MRCI-E). The cross-cultural adaptation process consisted of an independent translation by 3 clinical pharmacists and a backtranslation by 2 native English speakers. A reliability analysis was conducted on 20 elderly randomly selected patients. Two clinical pharmacists calculated the MRCI-E from discharge treatments and 2 months later. For the validity analysis, the sample was augmented to 60 patients. Convergent validity was assessed by analyzing the correlation between the number of medications; discriminant validity was stratified by gender; and predictive validity was determined by analyzing the ability to predict readmission and mortality at 3 and 6 months. The MRCI-E retained the original structure of 3 sections. The reliability analysis demonstrated an excellent internal consistency (Cronbach's α=0.83), and the intraclass correlation coefficient exceeded 0.9 in all cases. The correlation coefficient with the number of medications was 0.883 ( P<0.001). No significant differences were found when stratified by gender (3.6; 95%CI=-2.9 to 10.2; P=0.27). Patients who were readmitted at 3 months had a higher MRCI-E score (10.7; 95%CI=4.4 to 17.2; P=0.001). The differences remained significant in patients readmitted at 6 months, but differences in mortality were not detected. The MRCI-E retains the reliability and validity of the original index and provides a suitable tool to assess the complexity of medication regimens in Spanish.
Cross-cultural adaptation and validation of the Korean version of the Michigan hand questionnaire.
Roh, Young Hak; Yang, Bo Kyu; Noh, Jung Ho; Baek, Goo Hyun; Song, Cheol Ho; Gong, Hyun Sik
2011-09-01
The Michigan hand questionnaire (MHQ) is increasingly being used and has been adapted cross-culturally in some Western and Asian countries, but the validation process for an Asian translation of MHQ has not been well described. In this study, we translated and adapted the original MHQ cross-culturally to produce a Korean version, and then assessed the validity and reliability of the Korean version of the MHQ. A total of 176 patients with common hand disorders completed the Korean version of the MHQ and the Disabilities of the Arm, Shoulder, and Hand questionnaire. We included the pain score assessed by a visual analog scale during activity, range of motion, measurement of grip strength, and subjective assessment of the functional state by use of Cooney's scale in the validation process. There were no major linguistic or cultural problems during forward and backward translations of the MHQ, except for a minor change owing to cultural discrepancies in eating, such as the dominant hand using a spoon and chopsticks instead of both hands using a knife and fork. All subscales of the MHQ showed satisfactory internal consistency. The reproducibility test showed no significant difference. The construct validity revealed a moderate to strong correlation between every subscale of the Korean MHQ against DASH disabilities and symptoms. The aesthetic and satisfaction domains, unique domains of the MHQ, had little correlation with the objective measure of the pain visual analog scale, grip strength, motion and subjective functional state. The Korean version of MHQ showed satisfactory internal consistency, test-retest reliability, and validity and demonstrated a significant correlation with the patient-based upper extremity questionnaire and clinical assessment. We found the application and evaluation of the instrument to be feasible and understandable among patients in Korea. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Cross-cultural adaptation and validation of the teamwork climate scale
Silva, Mariana Charantola; Peduzzi, Marina; Sangaleti, Carine Teles; da Silva, Dirceu; Agreli, Heloise Fernandes; West, Michael A; Anderson, Neil R
2016-01-01
ABSTRACT OBJECTIVE To adapt and validate the Team Climate Inventory scale, of teamwork climate measurement, for the Portuguese language, in the context of primary health care in Brazil. METHODS Methodological study with quantitative approach of cross-cultural adaptation (translation, back-translation, synthesis, expert committee, and pretest) and validation with 497 employees from 72 teams of the Family Health Strategy in the city of Campinas, SP, Southeastern Brazil. We verified reliability by the Cronbach’s alpha, construct validity by the confirmatory factor analysis with SmartPLS software, and correlation by the job satisfaction scale. RESULTS We problematized the overlap of items 9, 11, and 12 of the “participation in the team” factor and the “team goals” factor regarding its definition. The validation showed no overlapping of items and the reliability ranged from 0.92 to 0.93. The confirmatory factor analysis indicated suitability of the proposed model with distribution of the 38 items in the four factors. The correlation between teamwork climate and job satisfaction was significant. CONCLUSIONS The version of the scale in Brazilian Portuguese was validated and can be used in the context of primary health care in the Country, constituting an adequate tool for the assessment and diagnosis of teamwork. PMID:27556966
Concurrent Validity of the International Family Quality of Life Survey.
Samuel, Preethy S; Pociask, Fredrick D; DiZazzo-Miller, Rosanne; Carrellas, Ann; LeRoy, Barbara W
2016-01-01
The measurement of the social construct of Family Quality of Life (FQOL) is a parsimonious alternative to the current approach of measuring familial outcomes using a battery of tools related to individual-level outcomes. The purpose of this study was to examine the internal consistency and concurrent validity of the International FQOL Survey (FQOLS-2006), using cross-sectional data collected from 65 family caregivers of children with developmental disabilities. It shows a moderate correlation between the total FQOL scores of the FQOLS-2006 and the Beach Center's FQOL scale. The validity of five FQOLS-2006 domains was supported by the correlations between conceptually related domains.
Oyeyemi, Adewale L; Oyeyemi, Adetoyeje Y; Adegoke, Babatunde O; Oyetoke, Fatima O; Aliyu, Habeeb N; Aliyu, Salamatu U; Rufai, Adamu A
2011-11-22
Accurate assessment of physical activity is important in determining the risk for chronic diseases such as cardiovascular disease, stroke, type 2 diabetes, cancer and obesity. The absence of culturally relevant measures in indigenous languages could pose challenges to epidemiological studies on physical activity in developing countries. The purpose of this study was to translate and cross-culturally adapt the Short International Physical Activity Questionnaire (IPAQ-SF) to the Hausa language, and to evaluate the validity and reliability of the Hausa version of IPAQ-SF in Nigeria. The English IPAQ-SF was translated into the Hausa language, synthesized, back translated, and subsequently subjected to expert committee review and pre-testing. The final product (Hausa IPAQ-SF) was tested in a cross-sectional study for concurrent (correlation with the English version) and construct validity, and test-retest reliability in a sample of 102 apparently healthy adults. The Hausa IPAQ-SF has good concurrent validity with Spearman correlation coefficients (ρ) ranging from 0.78 for vigorous activity (Min Week-1) to 0.92 for total physical activity (Metabolic Equivalent of Task [MET]-Min Week-1), but poor construct validity, with cardiorespiratory fitness (ρ = 0.21, p = 0.01) and body mass index (ρ = 0.22, p = 0.04) significantly correlated with only moderate activity and sitting time (Min Week-1), respectively. Reliability was good for vigorous (ICC = 0.73, 95% C.I = 0.55-0.84) and total physical activity (ICC = 0.61, 95% C.I = 0.47-0.72), but fair for moderate activity (ICC = 0.33, 95% C.I = 0.12-0.51), and few meaningful differences were found in the gender and socioeconomic status specific analyses. The Hausa IPAQ-SF has acceptable concurrent validity and test-retest reliability for vigorous-intensity activity, walking, sitting and total physical activity, but demonstrated only fair construct validity for moderate and sitting activities. The Hausa IPAQ-SF can be used for physical activity measurements in Nigeria, but further construct validity testing with objective measures such as an accelerometer is needed.
Sucupira, Eduardo; Sabino, Miguel; Lima, Edson Luiz de; Dini, Gal Moreira; Brito, Maria José Azevedo de; Ferreira, Lydia Masako
2017-01-01
Patient-reported outcome measurements assessing the emotional state of children and adolescents who seek plastic surgery are important for determining whether the intervention is indicated or not. The aim of this study was to cross-culturally adapt and validate the Short Mood and Feelings Questionnaire (child/adolescent and parent versions) for Brazilian Portuguese, test its psychometric properties and assess the emotional state of children and adolescents who seek plastic surgery. DESIGN AND SETTING: Cross-cultural validation study conducted in a plastic surgery outpatient clinic at a public university hospital. A total of 124 consecutive patients of both sexes were selected between September 2013 and February 2014. Forty-seven patients participated in the cultural adaptation of the questionnaire. The final version was tested for reliability on 20 patients. Construct validity was tested on 57 patients by correlating the Short Mood and Feelings Questionnaire (child/adolescent and parent versions) with the Strengths and Difficulties Questionnaire and the Rosenberg Self-Esteem scale. The child/adolescent and parent versions of the Short Mood and Feelings Questionnaire showed Cronbach's alpha of 0.768 and 0.874, respectively, and had good inter-rater reliability (intraclass correlation coefficient, ICC = 0.757 and ICC = 0.853, respectively) and intra-rater reliability (ICC = 0.738 and ICC = 0.796, respectively). The Brazilian-Portuguese version of the Short Mood and Feelings Questionnaire is a reproducible instrument with face, content and construct validity.The mood state and feelings among children and adolescents seeking cosmetic surgery were healthy.
NASA Astrophysics Data System (ADS)
Cao, Guangxi; Zhang, Minjia; Li, Qingchen
2017-04-01
This study focuses on multifractal detrended cross-correlation analysis of the different volatility intervals of Mainland China, US, and Hong Kong stock markets. A volatility-constrained multifractal detrended cross-correlation analysis (VC-MF-DCCA) method is proposed to study the volatility conductivity of Mainland China, US, and Hong Kong stock markets. Empirical results indicate that fluctuation may be related to important activities in real markets. The Hang Seng Index (HSI) stock market is more influential than the Shanghai Composite Index (SCI) stock market. Furthermore, the SCI stock market is more influential than the Dow Jones Industrial Average stock market. The conductivity between the HSI and SCI stock markets is the strongest. HSI was the most influential market in the large fluctuation interval of 1991 to 2014. The autoregressive fractionally integrated moving average method is used to verify the validity of VC-MF-DCCA. Results show that VC-MF-DCCA is effective.
Gao, X X; Zhu, L; Yu, S J; Xu, T
2018-02-25
Objective: To develop the Chinese version of modified body image scale (MBIS) questionnaires, and to validate them in Chinese population. Methods: The original English MBIS questionnaire was translated into Chinese, following the WHO cross-cultural adaptation of health-related quality of life measures. The reliability and validity of the Chinese version of MBIS questionnaires were evaluated in Chinese population, MRKH syndrome patients. Results: Totally 50 patients with MRKH syndrome completed the MBIS and short-form 12-item health survey (SF-12) questionnaires. The Cronbach's alpha of MBIS was 0.741, intraclass correlation coefficients were 0.472-0.815 ( P< 0.01). MBIS scores were positively correlated with SF-12 scores (Spearman correlation coefficient was-0.409, P< 0.01) . Factor analysis showed that MBIS had one common factor. Conclusion: Chinese version of MBIS has high reliability and validity in Chinese population, therefore is suitable for clinic and research.
Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Kachooei, Amir Reza
2015-01-01
We aimed to validate a cross-culturally adapted version of the Persian Michigan Hand Outcomes Questionnaire (MHOQ). We followed the Beaton's guideline to translate the questionnaire to Persian. We administered the final version to 223 patients among which 79 patients returned 3 days later to respond to the Persian MHOQ for the second time. In the first visit, respondents also filled the Disabilities of the Arm Shoulder and Hand (DASH) and rated the pain based on the Visual Analogue Scale (VAS). Cronbach's alpha for the total MHOQ was 0.79 which showed good internal consistency. Intraclass correlation coefficient (ICC) for the total MHOQ was 0.84 which demonstrated good reliability between test and retest. The absolute correlation coefficient between total MHOQ and the DASH was as high as 0.74. Persian version of the MHOQ proved to be a reliable and valid instrument to be implemented among Persian population with the hand and wrist disorders.
Ko, Young-Mi; Park, Won-Beom; Lim, Jae-Young
2010-03-15
Validation of a translated, culturally adapted questionnaire. We developed a Korean version of the Chronic Pain Coping Inventory-42 (CPCI-42) by performing a cross-cultural adaptation, and evaluated its reliability and validity. The CPCI is widely used and validated instruments for measuring coping strategies in chronic pain. However, no validated and culturally adapted version was available in Asian countries. We assessed 142 patients with chronic low back pain using the CPCI-42 and measures of physical disability, pain, and quality of life. Results for 93 of the 142 patients exhibited test-retest reliability. The interval time of collecting retest data varied from 2 weeks to 1 month. Criterion validity was evaluated using correlations between the CPCI-42 and the Oswestry Disability Index, the Brief Pain Inventory, and the Short Form 36-item Health Survey (version 2.0). Construct validity was computed using exploratory factor analysis. The Korean version of the CPCI-42 had a high internal consistency (Cronbach's alpha >0.70) with the exception of results for task persistence and relaxation. Illness-focused coping (guarding, resting, asking for assistance) and other-focused coping (seeking social support) were most significantly correlated with Oswestry Disability Index, Brief Pain Inventory, and Short Form 36-item Health Survey, respectively. Outcomes for task persistence were contrary to other subscales in wellness-focused coping. Construct validity by factor analysis produced similar results to the original CPCI subscale. However, several factors showed cross-loading in 8 factor solutions. Despite linguistic and cultural differences, the Korean version of the CPCI-42 is overall a meaningful tool, and produces results sufficiently similar to the original CPCI-42.
Crins, Martine H. P.; Roorda, Leo D.; Smits, Niels; de Vet, Henrica C. W.; Westhovens, Rene; Cella, David; Cook, Karon F.; Revicki, Dennis; van Leeuwen, Jaap; Boers, Maarten; Dekker, Joost; Terwee, Caroline B.
2015-01-01
The Dutch-Flemish PROMIS Group translated the adult PROMIS Pain Interference item bank into Dutch-Flemish. The aims of the current study were to calibrate the parameters of these items using an item response theory (IRT) model, to evaluate the cross-cultural validity of the Dutch-Flemish translations compared to the original English items, and to evaluate their reliability and construct validity. The 40 items in the bank were completed by 1085 Dutch chronic pain patients. Before calibrating the items, IRT model assumptions were evaluated using confirmatory factor analysis (CFA). Items were calibrated using the graded response model (GRM), an IRT model appropriate for items with more than two response options. To evaluate cross-cultural validity, differential item functioning (DIF) for language (Dutch vs. English) was examined. Reliability was evaluated based on standard errors and Cronbach’s alpha. To evaluate construct validity correlations with scores on legacy instruments (e.g., the Disabilities of the Arm, Shoulder and Hand Questionnaire) were calculated. Unidimensionality of the Dutch-Flemish PROMIS Pain Interference item bank was supported by CFA tests of model fit (CFI = 0.986, TLI = 0.986). Furthermore, the data fit the GRM and showed good coverage across the pain interference continuum (threshold-parameters range: -3.04 to 3.44). The Dutch-Flemish PROMIS Pain Interference item bank has good cross-cultural validity (only two out of 40 items showing DIF), good reliability (Cronbach’s alpha = 0.98), and good construct validity (Pearson correlations between 0.62 and 0.75). A computer adaptive test (CAT) and Dutch-Flemish PROMIS short forms of the Dutch-Flemish PROMIS Pain Interference item bank can now be developed. PMID:26214178
Crins, Martine H P; Roorda, Leo D; Smits, Niels; de Vet, Henrica C W; Westhovens, Rene; Cella, David; Cook, Karon F; Revicki, Dennis; van Leeuwen, Jaap; Boers, Maarten; Dekker, Joost; Terwee, Caroline B
2015-01-01
The Dutch-Flemish PROMIS Group translated the adult PROMIS Pain Interference item bank into Dutch-Flemish. The aims of the current study were to calibrate the parameters of these items using an item response theory (IRT) model, to evaluate the cross-cultural validity of the Dutch-Flemish translations compared to the original English items, and to evaluate their reliability and construct validity. The 40 items in the bank were completed by 1085 Dutch chronic pain patients. Before calibrating the items, IRT model assumptions were evaluated using confirmatory factor analysis (CFA). Items were calibrated using the graded response model (GRM), an IRT model appropriate for items with more than two response options. To evaluate cross-cultural validity, differential item functioning (DIF) for language (Dutch vs. English) was examined. Reliability was evaluated based on standard errors and Cronbach's alpha. To evaluate construct validity correlations with scores on legacy instruments (e.g., the Disabilities of the Arm, Shoulder and Hand Questionnaire) were calculated. Unidimensionality of the Dutch-Flemish PROMIS Pain Interference item bank was supported by CFA tests of model fit (CFI = 0.986, TLI = 0.986). Furthermore, the data fit the GRM and showed good coverage across the pain interference continuum (threshold-parameters range: -3.04 to 3.44). The Dutch-Flemish PROMIS Pain Interference item bank has good cross-cultural validity (only two out of 40 items showing DIF), good reliability (Cronbach's alpha = 0.98), and good construct validity (Pearson correlations between 0.62 and 0.75). A computer adaptive test (CAT) and Dutch-Flemish PROMIS short forms of the Dutch-Flemish PROMIS Pain Interference item bank can now be developed.
Wu, Mingwei; Li, Yan; Fu, Xinmei; Wang, Jinghui; Zhang, Shuwei; Yang, Ling
2014-09-01
Melanin concentrating hormone receptor 1 (MCHR1), a crucial regulator of energy homeostasis involved in the control of feeding and energy metabolism, is a promising target for treatment of obesity. In the present work, the up-to-date largest set of 181 quinoline/quinazoline derivatives as MCHR1 antagonists was subjected to both ligand- and receptor-based three-dimensional quantitative structure-activity (3D-QSAR) analysis applying comparative molecular field analysis (CoMFA) and comparative molecular similarity indices analysis (CoMSIA). The optimal predictable CoMSIA model exhibited significant validity with the cross-validated correlation coefficient (Q²) = 0.509, non-cross-validated correlation coefficient (R²(ncv)) = 0.841 and the predicted correlation coefficient (R²(pred)) = 0.745. In addition, docking studies and molecular dynamics (MD) simulations were carried out for further elucidation of the binding modes of MCHR1 antagonists. MD simulations in both water and lipid bilayer systems were performed. We hope that the obtained models and information may help to provide an insight into the interaction mechanism of MCHR1 antagonists and facilitate the design and optimization of novel antagonists as anti-obesity agents.
Construct validity of the PROMIS® sexual function and satisfaction measures in patients with cancer
2013-01-01
Background With data from a diverse sample of patients either in treatment for cancer or post-treatment for cancer, we examine inter-domain and cross-domain correlations among the core domains of the Patient-Reported Outcomes Measurement Information System Sexual Function and Satisfaction measures (PROMIS® SexFS) and the corresponding domains from conceptually-similar measures of sexual function, the International Index of Erectile Function and the Female Sexual Function Index. Findings Men (N=389) and women (N=430) were recruited from a tumor registry, oncology clinics, and an internet panel. The PROMIS SexFS, International Index of Erectile Function, and Female Sexual Function Index were used to collect participants’ self-reported sexual function. The domains shared among the measures include desire/interest in sexual activity, lubrication and vaginal discomfort/pain (women), erectile function (men), orgasm, and satisfaction. We examined correlations among different domains within the same instrument (discriminant validity) and correlations among similar domains measured by different instruments (convergent validity). Correlations demonstrating discriminant validity ranged from 0.38 to 0.73 for men and 0.48 to 0.74 for women, while correlations demonstrating convergent validity ranged from 0.62 to 0.83 for men and 0.71 to 0.92 for women. As expected, correlations demonstrating convergent validity were higher than correlations demonstrating discriminant validity, with one exception (orgasm for men). Conclusions Construct validity was supported by convergent and discriminant validity in a diverse sample of patients with cancer. For patients with cancer who may or may not have sexual dysfunction, the PROMIS SexFS measures provide a comprehensive assessment of key domains of sexual function and satisfaction. PMID:23497200
Individualism: a valid and important dimension of cultural differences between nations.
Schimmack, Ulrich; Oishi, Shigehiro; Diener, Ed
2005-01-01
Oyserman, Coon, and Kemmelmeier's (2002) meta-analysis suggested problems in the measurement of individualism and collectivism. Studies using Hofstede's individualism scores show little convergent validity with more recent measures of individualism and collectivism. We propose that the lack of convergent validity is due to national differences in response styles. Whereas Hofstede statistically controlled for response styles, Oyserman et al.'s meta-analysis relied on uncorrected ratings. Data from an international student survey demonstrated convergent validity between Hofstede's individualism dimension and horizontal individualism when response styles were statistically controlled, whereas uncorrected scores correlated highly with the individualism scores in Oyserman et al.'s meta-analysis. Uncorrected horizontal individualism scores and meta-analytic individualism scores did not correlate significantly with nations' development, whereas corrected horizontal individualism scores and Hofstede's individualism dimension were significantly correlated with development. This pattern of results suggests that individualism is a valid construct for cross-cultural comparisons, but that the measurement of this construct needs improvement.
Criterion Validity of the Child's Challenging Behavior Scale, Version 2 (CCBS-2).
Bourke-Taylor, Helen M; Cordier, Reinie; Pallant, Julie F
The Child's Challenging Behavior Scale, Version 2 (CCBS-2), measures maternal rating of a child's challenging behaviors that compromise maternal mental health. The CCBS-2, the Child Behavior Checklist (CBCL), and the Strengths and Difficulties Questionnaire (SDQ) were compared in a sample of typically developing young Australian children. Criterion validity was investigated by correlating the CCBS-2 with "gold standard" measures (CBCL and SDQ subscales). Data were collected in a cross-sectional survey of mothers (N = 336) of children ages 3-9 yr. Correlations with the CBCL externalizing subscales demonstrated moderate (ρ = .46) to strong (ρ = .66) correlations. Correlations with the SDQ externalizing behaviors subscales were moderate (ρ = .35) to strong (ρ = .60). The criterion validity established in this study strengthens the psychometric properties that support ongoing development of the CCBS-2 as an efficient tool that may identify children in need of further evaluation. Copyright © 2018 by the American Occupational Therapy Association, Inc.
Saloheimo, T; González, S A; Erkkola, M; Milauskas, D M; Meisel, J D; Champagne, C M; Tudor-Locke, C; Sarmiento, O; Katzmarzyk, P T; Fogelholm, M
2015-01-01
Objective: The main aim of this study was to assess the reliability and validity of a food frequency questionnaire with 23 food groups (I-FFQ) among a sample of 9–11-year-old children from three different countries that differ on economical development and income distribution, and to assess differences between country sites. Furthermore, we assessed factors associated with I-FFQ's performance. Methods: This was an ancillary study of the International Study of Childhood Obesity, Lifestyle and the Environment. Reliability (n=321) and validity (n=282) components of this study had the same participants. Participation rates were 95% and 70%, respectively. Participants completed two I-FFQs with a mean interval of 4.9 weeks to assess reliability. A 3-day pre-coded food diary (PFD) was used as the reference method in the validity analyses. Wilcoxon signed-rank tests, intraclass correlation coefficients and cross-classifications were used to assess the reliability of I-FFQ. Spearman correlation coefficients, percentage difference and cross-classifications were used to assess the validity of I-FFQ. A logistic regression model was used to assess the relation of selected variables with the estimate of validity. Analyses based on information in the PFDs were performed to assess how participants interpreted food groups. Results: Reliability correlation coefficients ranged from 0.37 to 0.78 and gross misclassification for all food groups was <5%. Validity correlation coefficients were below 0.5 for 22/23 food groups, and they differed among country sites. For validity, gross misclassification was <5% for 22/23 food groups. Over- or underestimation did not appear for 19/23 food groups. Logistic regression showed that country of participation and parental education were associated (P⩽0.05) with the validity of I-FFQ. Analyses of children's interpretation of food groups suggested that the meaning of most food groups was understood by the children. Conclusion: I-FFQ is a moderately reliable method and its validity ranged from low to moderate, depending on food group and country site. PMID:27152180
Translation, cross-cultural adaptation and validation of the Diabetes Empowerment Scale – Short Form
Chaves, Fernanda Figueredo; Reis, Ilka Afonso; Pagano, Adriana Silvina; Torres, Heloísa de Carvalho
2017-01-01
ABSTRACT OBJECTIVE To translate, cross-culturally adapt and validate the Diabetes Empowerment Scale – Short Form for assessment of psychosocial self-efficacy in diabetes care within the Brazilian cultural context. METHODS Assessment of the instrument’s conceptual equivalence, as well as its translation and cross-cultural adaptation were performed following international standards. The Expert Committee’s assessment of the translated version was conducted through a web questionnaire developed and applied via the web tool e-Surv. The cross-culturally adapted version was used for the pre-test, which was carried out via phone call in a group of eleven health care service users diagnosed with type 2 diabetes mellitus. The pre-test results were examined by a group of experts, composed by health care consultants, applied linguists and statisticians, aiming at an adequate version of the instrument, which was subsequently used for test and retest in a sample of 100 users diagnosed with type 2 diabetes mellitus via phone call, their answers being recorded by the web tool e-Surv. Internal consistency and reproducibility of analysis were carried out within the statistical programming environment R. RESULTS Face and content validity were attained and the Brazilian Portuguese version, entitled Escala de Autoeficácia em Diabetes – Versão Curta, was established. The scale had acceptable internal consistency with Cronbach’s alpha of 0.634 (95%CI 0.494– 0.737), while the correlation of the total score in the two periods was considered moderate (0.47). The intraclass correlation coefficient was 0.50. CONCLUSIONS The translated and cross-culturally adapted version of the instrument to spoken Brazilian Portuguese was considered valid and reliable to be used for assessment within the Brazilian population diagnosed with type 2 diabetes mellitus. The use of a web tool (e-Surv) for recording the Expert Committee responses as well as the responses in the validation tests proved to be a reliable, safe and innovative method. PMID:28355337
ERIC Educational Resources Information Center
Hagborg, Winston J.
1993-01-01
Administered Rosenberg Self-Esteem Scale (RSE) and Harter's Self-Perception Profile for Adolescents to 150 adolescents in grades 8 through 12. Correlational and cross-validation multiple regression analyses found that RSE total score and both its factor scores were strongly related to Global Self-Worth. Females reported significantly lower RSE…
Core Noise Diagnostics of Turbofan Engine Noise Using Correlation and Coherence Functions
NASA Technical Reports Server (NTRS)
Miles, Jeffrey H.
2009-01-01
Cross-correlation and coherence functions are used to look for periodic acoustic components in turbofan engine combustor time histories, to investigate direct and indirect combustion noise source separation based on signal propagation time delays, and to provide information on combustor acoustics. Using the cross-correlation function, time delays were identified in all cases, clearly indicating the combustor is the source of the noise. In addition, unfiltered and low-pass filtered at 400 Hz signals had a cross-correlation time delay near 90 ms, while the low-pass filtered at less than 400 Hz signals had a cross-correlation time delay longer than 90 ms. Low-pass filtering at frequencies less than 400 Hz partially removes the direct combustion noise signals. The remainder includes the indirect combustion noise signal, which travels more slowly because of the dependence on the entropy convection velocity in the combustor. Source separation of direct and indirect combustion noise is demonstrated by proper use of low-pass filters with the cross-correlation function for a range of operating conditions. The results may lead to a better idea about the acoustics in the combustor and may help develop and validate improved reduced-order physics-based methods for predicting direct and indirect combustion noise.
Huang, Hui-Chuan; Shyu, Meei-Ling; Lin, Mei-Feng; Hu, Chaur-Jong; Chang, Chien-Hung; Lee, Hsin-Chien; Chi, Nai-Fang; Chang, Hsiu-Ju
2017-12-01
The objectives of this study were to develop a cross-cultural Chinese version of the Emotional and Social Dysfunction Questionnaire (ESDQ-C) and test its validity and reliability among Chinese-speaking stroke patients. Various methods were used to develop the ESDQ-C. A cross-sectional study was used to examine the validity and reliability of the developed questionnaire, which consists of 28 items belonging to six factors, anger, helplessness, emotional dyscontrol, indifference, inertia and fatigue, and euphoria. Satisfactory convergence and known-group validities were confirmed by significant correlations of the ESDQ-C with the Profile of Mood States-Short Form ( p < .05) and with the Hospital Anxiety and Depression Scale ( p < .05). The internal consistency was represented by Cronbach's alpha, which was .96 and .79 to .92 for the entire scale and subscales, respectively. Appropriate application of the ESDQ-C will be helpful to identify critical adjustment-related types of distress and patients who experience difficulty coping with such distress.
Cross-cultural Adaption and Validation of the Danish Voice Handicap Index.
Sorensen, Jesper Roed; Printz, Trine; Mehlum, Camilla Slot; Heidemann, Christian Hamilton; Groentved, Aagot Moeller; Godballe, Christian
2018-02-02
We aimed to assess psychometric properties, including internal consistency, reliability, and clinical validity of the Danish version of the Voice Handicap Index (VHI). A cross-sectional survey study was carried out. For validation, the existing nonvalidated Danish version of the VHI was used. Data from 208 patients with voice disorders of different etiology (neurogenic, functional, and structural) and a control group of 85 vocally healthy individuals were included. A test-retest reliability analysis of 42 patients and 45 control persons was performed. The internal consistency, test-retest reliability, and clinical validity of the questionnaire were assessed. Internal consistency was high with a Cronbach α >0.90 for both the patient and control group. Test-retest reliability measured as intraclass correlation coefficient was good with 0.93 (95% confidence interval [95% confidence interval]: 0.87-0.96) for patients and 0.78 (95% confidence interval: 0.63-0.87) for the control group which indicates sufficient reliability of the questionnaire. The Danish VHI has good clinical validity as it has a strong correlation between patient's perception of the severity of their voice disorder and the VHI score from the Spearman correlation of 0.69. The existing Danish version of the VHI has been thoroughly validated and found to be in line with the original VHI from Jacobsen et al. It showed good internal consistency, test-retest reliability, and clinical validity. It is suitable for use in daily practice and in research projects as it is able to assess patients' perception of their voice disorder severity. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Boer, Annemarie; Dutmer, Alisa L; Schiphorst Preuper, Henrica R; van der Woude, Lucas H V; Stewart, Roy E; Deyo, Richard A; Reneman, Michiel F; Soer, Remko
2017-10-01
Validation study with cross-sectional and longitudinal measurements. To translate the US National Institutes of Health (NIH)-minimal dataset for clinical research on chronic low back pain into the Dutch language and to test its validity and reliability among people with chronic low back pain. The NIH developed a minimal dataset to encourage more complete and consistent reporting of clinical research and to be able to compare studies across countries in patients with low back pain. In the Netherlands, the NIH-minimal dataset has not been translated before and measurement properties are unknown. Cross-cultural validity was tested by a formal forward-backward translation. Structural validity was tested with exploratory factor analyses (comparative fit index, Tucker-Lewis index, and root mean square error of approximation). Hypothesis testing was performed to compare subscales of the NIH dataset with the Pain Disability Index and the EurQol-5D (Pearson correlation coefficients). Internal consistency was tested with Cronbach α and test-retest reliability at 2 weeks was calculated in a subsample of patients with Intraclass Correlation Coefficients and weighted Kappa (κω). In total, 452 patients were included of which 52 were included for the test-retest study. factor analysis for structural validity pointed into the direction of a seven-factor model (Cronbach α = 0.78). Factors and total score of the NIH-minimal dataset showed fair to good correlations with Pain Disability Index (r = 0.43-0.70) and EuroQol-5D (r = -0.41 to -0.64). Reliability: test-retest reliability per item showed substantial agreement (κω=0.65). Test-retest reliability per factor was moderate to good (Intraclass Correlation Coefficient = 0.71). The Dutch language version measurement properties of the NIH-minimal were satisfactory. N/A.
Validation analysis of informant's ratings of cognitive function in African Americans and Nigerians
Shen, Jianzhao; Gao, Sujuan; Unverzagt, Frederick W.; Ogunniyi, Adesola; Baiyewu, Olusegun; Gureje, Oye; Hendrie, Hugh C.; Hall, Kathleen S.
2011-01-01
SUMMARY Objectives To examine informant validity using the Community Screening Interview for Dementia (CSI ‘D’) both cross-sectionally and longitudinally in two very different cultures and to explore the effects of informants and study participants’ characteristics on the validity of informants’ reports. Methods Elderly African Americans age 65 years and older residing in Indianapolis, USA and elderly Yoruba Nigerians age 65 years and older residing in Ibadan, Nigeria were assessed on cognitive functioning using the CSI ‘D’ at baseline (1992–1993) and five-year follow-up (1997–1998). At baseline, the informant validity in both samples was evaluated against participants’ cognitive tests using Pearson correlation and regular regression models. At follow-up, informants ratings on cognitive decline were assessed against participants’ cognitive decline scores from baseline to follow-up using biserial correlation and logistic regressions. Results At baseline, informants’ reports on cognitive functioning significantly correlated with cognitive scores in both samples (Indianapolis:r = –0.43, p < 0.001; Ibadan:r = –0.47, p < 0.001). The participant–informant relationships significantly affected the informants’ reports in the two samples with different patterns (p = 0.005 for Indianapolis and p < 0.001 for Ibadan) at a given level of cognitive functioning. African Americans spouses reported more cognitive problems, while siblings reported more problems for the Yoruba Nigerians. At follow-up, informants’ ratings on cognitive decline significantly correlated with the cognitive decline scores (Indianapolis r = 0.38, p < 0.001; Ibadan r = 0.32, p < 0.001). The characteristics of study participants and informants had little impact on the informants’ ratings on cognitive decline. Conclusions Informant reports are valid in assessing the cognitive functioning of study participants both cross-sectionally and longitudinally in two very different cultures, languages and environments. PMID:16802282
Flosadottir, Vala; Roos, Ewa M; Ageberg, Eva
2017-09-01
The Activity Rating Scale (ARS) for disorders of the knee evaluates the level of activity by the frequency of participation in 4 separate activities with high demands on knee function, with a score ranging from 0 (none) to 16 (pivoting activities 4 times/wk). To translate and cross-culturally adapt the ARS into Swedish and to assess measurement properties of the Swedish version of the ARS. Cohort study (diagnosis); Level of evidence, 2. The COSMIN guidelines were followed. Participants (N = 100 [55 women]; mean age, 27 years) who were undergoing rehabilitation for a knee injury completed the ARS twice for test-retest reliability. The Knee injury and Osteoarthritis Outcome Score (KOOS), Tegner Activity Scale (TAS), and modernized Saltin-Grimby Physical Activity Level Scale (SGPALS) were administered at baseline to validate the ARS. Construct validity and responsiveness of the ARS were evaluated by testing predefined hypotheses regarding correlations between the ARS, KOOS, TAS, and SGPALS. The Cronbach alpha, intraclass correlation coefficients, absolute reliability, standard error of measurement, smallest detectable change, and Spearman rank-order correlation coefficients were calculated. The ARS showed good internal consistency (α ≈ 0.96), good test-retest reliability (intraclass correlation coefficient >0.9), and no systematic bias between measurements. The standard error of measurement was less than 2 points, and the smallest detectable change was less than 1 point at the group level and less than 5 points at the individual level. More than 75% of the hypotheses were confirmed, indicating good construct validity and good responsiveness of the ARS. The Swedish version of the ARS is valid, reliable, and responsive for evaluating the level of activity based on the frequency of participation in high-demand knee sports activities in young adults with a knee injury.
Introduction of Total Variation Regularization into Filtered Backprojection Algorithm
NASA Astrophysics Data System (ADS)
Raczyński, L.; Wiślicki, W.; Klimaszewski, K.; Krzemień, W.; Kowalski, P.; Shopa, R. Y.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B.; Jasińska, B.; Kisielewska-Kamińska, D.; Korcyl, G.; Kozik, T.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Niedźwiecki, S.; Pałka, M.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method.
Guedes, Keyte; Pereira, Cecília; Pavan, Karina; Valério, Berenice Cataldo Oliveira
2010-02-01
The aim of this study is the cross-cultural, as well as to validate in Portuguese language the Amyotrophic Lateral Sclerosis Functional Rating Scale - Revised (ALSFRS-R). We performed a prospective study of individuals with amyotrophic lateral sclerosis (ALS) clinically defined. The scale, after obtaining the final version in Portuguese, was administered in 22 individuals and three weeks after re-applied. There were no significant differences between the application and reapplication of the scale (p=0.069). The linear regression and internal consistency measured by Pearson correlation and alpha Conbrach were significant with r=0.975 e alpha=0.934. The reliability test-retest demonstrated by intraclass correlation coefficient was strong with ICC=0.975. Therefore, this version proved to be applicable, reliable and easy to be conducted in clinical practice and research.
Bairy, Santhosh Kumar; Suneel Kumar, B V S; Bhalla, Joseph Uday Tej; Pramod, A B; Ravikumar, Muttineni
2009-04-01
c-Src kinase play an important role in cell growth and differentiation and its inhibitors can be useful for the treatment of various diseases, including cancer, osteoporosis, and metastatic bone disease. Three dimensional quantitative structure-activity relationship (3D-QSAR) studies were carried out on quinazolin derivatives inhibiting c-Src kinase. Molecular field analysis (MFA) models with four different alignment techniques, namely, GLIDE, GOLD, LIGANDFIT and Least squares based methods were developed. glide based MFA model showed better results (Leave one out cross validation correlation coefficient r(2)(cv) = 0.923 and non-cross validation correlation coefficient r(2)= 0.958) when compared with other models. These results help us to understand the nature of descriptors required for activity of these compounds and thereby provide guidelines to design novel and potent c-Src kinase inhibitors.
Cross-cultural adaption and validation of the Persian version of the SWAL-QOL.
Tarameshlu, Maryam; Azimi, Amir Reza; Jalaie, Shohreh; Ghelichi, Leila; Ansari, Noureddin Nakhostin
2017-06-01
The aim of this study was to translate and cross-culturally adapt the swallowing quality-of-life questionnaire (SWAL-QOL) to Persian language and to determine validity and reliability of the Persian version of the swallow quality-of-life questionnaire (PSWAL-QOL) in the patients with oropharyngeal dysphagia.The cross-sectional survey was designed to translate and cross-culturally adapt SWAL-QOL to Persian language following steps recommended in guideline. A total of 142 patients with dysphagia (mean age = 56.7 ± 12.22 years) were selected by non-probability consecutive sampling method to evaluate construct validity and internal consistency. Thirty patients with dysphagia were completed the PSWAL-QOL 2 weeks later for test-retest reliability.The PSWAL-QOL was favorably accepted with no missing items. The floor effect was ranged 0% to 21% and ceiling effect was ranged 0% to 16%. The construct validity was established via exploratory factor analysis. Internal consistency was confirmed with Cronbach α >0.7 for all scales except eating duration (α = 0.68). The test-retest reliability was excellent with intraclass correlation coefficient (ICC) ≥0.75 for all scales.The SWAL-QOL was cross-culturally adapted to Persian and demonstrated to be a valid and reliable self-report questionnaire to measure the impact of dysphagia on the quality-of-life in the Persian patients with oropharyngeal dysphagia.
Cross-cultural adaption and validation of the Persian version of the SWAL-QOL
Tarameshlu, Maryam; Azimi, Amir Reza; Jalaie, Shohreh; Ghelichi, Leila; Ansari, Noureddin Nakhostin
2017-01-01
Abstract The aim of this study was to translate and cross-culturally adapt the swallowing quality-of-life questionnaire (SWAL-QOL) to Persian language and to determine validity and reliability of the Persian version of the swallow quality-of-life questionnaire (PSWAL-QOL) in the patients with oropharyngeal dysphagia. The cross-sectional survey was designed to translate and cross-culturally adapt SWAL-QOL to Persian language following steps recommended in guideline. A total of 142 patients with dysphagia (mean age = 56.7 ± 12.22 years) were selected by non-probability consecutive sampling method to evaluate construct validity and internal consistency. Thirty patients with dysphagia were completed the PSWAL-QOL 2 weeks later for test–retest reliability. The PSWAL-QOL was favorably accepted with no missing items. The floor effect was ranged 0% to 21% and ceiling effect was ranged 0% to 16%. The construct validity was established via exploratory factor analysis. Internal consistency was confirmed with Cronbach α >0.7 for all scales except eating duration (α = 0.68). The test–retest reliability was excellent with intraclass correlation coefficient (ICC) ≥0.75 for all scales. The SWAL-QOL was cross-culturally adapted to Persian and demonstrated to be a valid and reliable self-report questionnaire to measure the impact of dysphagia on the quality-of-life in the Persian patients with oropharyngeal dysphagia. PMID:28658118
Cross-cultural adaptation and validation of the Korean version of the neck disability index.
Song, Kyung-Jin; Choi, Byung-Wan; Choi, Byung-Ryeul; Seo, Gyeu-Beom
2010-09-15
Validation of a translated, culturally adapted questionnaire. The purpose of this study is to translate and culturally adapt the Neck Disability Index (NDI) and to validate the use of the derived version in Korean patient. Although several valid measures exist for measurement of neck pain and functional impairment, these measures have yet been validated in Korean version. The NDI was linguistically translated into Korean, and prefinal version was assessed and modified by a pilot study. The reliability and validity of the derived Korean version was examined in 78 patients with degenerative cervical spine disease. Test-retest reliability, internal consistency, and construct validity were investigated by comparing Visual Analogue Scale (VAS) and Short Form Health Survey (SF-36) scores. Factor analysis of Korean NDI extracted 2 factors with eigenvalues >1. The intraclass-correlation coefficient of test-retest reliability was 0.93. Reliability, estimated by internal consistency, had a Cronbach alpha value of 0.82. The correlation between NDI and VAS scores was r = 0.49, and the correlation between NDI and SF-36 scores was r = -0.44. The physical health component score of SF-36 was highly correlated with NDI, and the correlation between VAS scores and the mental health component scores of SF-36 was high. The derived Korean version of the NDI was found to be a reliable and valid instrument for measuring disability in Korean patients with cervical problems. The authors recommend its use in future Korean clinical studies.
2012-01-01
Background The purpose of this study was to examine the internal consistency, test-retest reliability, construct validity and predictive validity of a new German self-report instrument to assess the influence of social support and the physical environment on physical activity in adolescents. Methods Based on theoretical consideration, the short scales on social support and physical environment were developed and cross-validated in two independent study samples of 9 to 17 year-old girls and boys. The longitudinal sample of Study I (n = 196) was recruited from a German comprehensive school, and subjects in this study completed the questionnaire twice with a between-test interval of seven days. Cronbach’s alphas were computed to determine the internal consistency of the factors. Test-retest reliability of the latent factors was assessed using intra-class coefficients. Factorial validity of the scales was assessed using principle components analysis. Construct validity was determined using a cross-validation technique by performing confirmatory factor analysis with the independent nationwide cross-sectional sample of Study II (n = 430). Correlations between factors and three measures of physical activity (objectively measured moderate-to-vigorous physical activity (MVPA), self-reported habitual MVPA and self-reported recent MVPA) were calculated to determine the predictive validity of the instrument. Results Construct validity of the social support scale (two factors: parental support and peer support) and the physical environment scale (four factors: convenience, public recreation facilities, safety and private sport providers) was shown. Both scales had moderate test-retest reliability. The factors of the social support scale also had good internal consistency and predictive validity. Internal consistency and predictive validity of the physical environment scale were low to acceptable. Conclusions The results of this study indicate moderate to good reliability and construct validity of the social support scale and physical environment scale. Predictive validity was only confirmed for the social support scale but not for the physical environment scale. Hence, it remains unclear if a person’s physical environment has a direct or an indirect effect on physical activity behavior or a moderation function. PMID:22928865
Reimers, Anne K; Jekauc, Darko; Mess, Filip; Mewes, Nadine; Woll, Alexander
2012-08-29
The purpose of this study was to examine the internal consistency, test-retest reliability, construct validity and predictive validity of a new German self-report instrument to assess the influence of social support and the physical environment on physical activity in adolescents. Based on theoretical consideration, the short scales on social support and physical environment were developed and cross-validated in two independent study samples of 9 to 17 year-old girls and boys. The longitudinal sample of Study I (n = 196) was recruited from a German comprehensive school, and subjects in this study completed the questionnaire twice with a between-test interval of seven days. Cronbach's alphas were computed to determine the internal consistency of the factors. Test-retest reliability of the latent factors was assessed using intra-class coefficients. Factorial validity of the scales was assessed using principle components analysis. Construct validity was determined using a cross-validation technique by performing confirmatory factor analysis with the independent nationwide cross-sectional sample of Study II (n = 430). Correlations between factors and three measures of physical activity (objectively measured moderate-to-vigorous physical activity (MVPA), self-reported habitual MVPA and self-reported recent MVPA) were calculated to determine the predictive validity of the instrument. Construct validity of the social support scale (two factors: parental support and peer support) and the physical environment scale (four factors: convenience, public recreation facilities, safety and private sport providers) was shown. Both scales had moderate test-retest reliability. The factors of the social support scale also had good internal consistency and predictive validity. Internal consistency and predictive validity of the physical environment scale were low to acceptable. The results of this study indicate moderate to good reliability and construct validity of the social support scale and physical environment scale. Predictive validity was only confirmed for the social support scale but not for the physical environment scale. Hence, it remains unclear if a person's physical environment has a direct or an indirect effect on physical activity behavior or a moderation function.
[Validation of the German version of the Oxford Elbow Score : A cross-sectional study].
Marquardt, J; Schöttker-Königer, T; Schäfer, A
2016-08-01
Elbow complaints are complex problems leading to severe consequences for affected people and the healthcare system. The German version of the Oxford Elbow Score (OES) is the first German-speaking instrument that specifically measures elbow complaints from the patient's perspective and changes of their health status. The aim of this study is the validation of the German version of the OES. In this context the internal consistency and the construct validity were investigated. 59 patients with elbow complaints completed the German version of the OES, the DASH and the SF-36 in a cross-sectional study. The internal consistency was calculated with Cronbach's alpha coefficients. Spearman's correlation coefficients were used to confirm construct validity. Cronbach's alpha for pain, function and psychological subscales was 0.88, 0.81 and 0.90, respectively. The whole questionnaire presents a Cronbach's alpha value of 0.93. Convergent construct validity was confirmed with correlation coefficients containing values of -0.84, -0.77 and -0.82 compared to DASH and values ranging from 0.41 to 0.80 compared with the physical domains of the SF-36. The divergent construct validity presented values ranging from 0.07 to 0.20 with the SF-36 domains of "general health perception" and "mental health". The German OES is an internal consistent instrument with good convergent and divergent construct validity. Other aspects of the validity, the reliability and the responsiveness should be confirmed through further studies.
On comprehensive recovery of an aftershock sequence with cross correlation
NASA Astrophysics Data System (ADS)
Kitov, I.; Bobrov, D.; Coyne, J.; Turyomurugyendo, G.
2012-04-01
We have introduced cross correlation between seismic waveforms as a technique for signal detection and automatic event building at the International Data Centre (IDC) of the Comprehensive Nuclear-Test-Ban Treaty Organization. The intuition behind signal detection is simple - small and mid-sized seismic events close in space should produce similar signals at the same seismic stations. Equivalently, these signals have to be characterized by a high cross correlation coefficient. For array stations with many individual sensors distributed over a large area, signals from events at distances beyond, say, 50 km, are subject to destructive interference when cross correlated due to changing time delays between various channels. Thus, any cross correlation coefficient above some predefined threshold can be considered as a signature of a valid signal. With a dense grid of master events (spacing between adjacent masters between 20 km and 50 km corresponds to the statistically estimated correlation distance) with high quality (signal-to-noise ratio above 10) template waveforms at primary array stations of the International Monitoring System one can detect signals from and then build natural and manmade seismic events close to the master ones. The use of cross correlation allows detecting smaller signals (sometimes below noise level) than provided by the current IDC detecting techniques. As a result it is possible to automatically build from 50% to 100% more valid seismic events than included in the Reviewed Event Bulletin (REB). We have developed a tentative pipeline for automatic processing at the IDC. It includes three major stages. Firstly, we calculate cross correlation coefficient for a given master and continuous waveforms at the same stations and carry out signal detection as based on the statistical behavior of signal-to-noise ratio of the cross correlation coefficient. Secondly, a thorough screening is performed for all obtained signals using f-k analysis and F-statistics as applied to the cross-correlation traces at individual channels of all included array stations. Thirdly, local (i.e. confined to the correlation distance around the master event) association of origin times of all qualified signals is fulfilled. These origin times are calculated from the arrival times of these signals, which are reduced to the origin times by the travel times from the master event. An aftershock sequence of a mid-size earthquake is an ideal case to test cross correlation techniques for autiomatic event building. All events should be close to the mainshock and occur within several days. Here we analyse the aftershock sequence of an earthquake in the North Atlantic Ocean with mb(IDC)=4.79. The REB includes 38 events at distances less than 150 km from the mainshock. Our ultimate goal is to excersice the complete iterative procedure to find all possible aftershocks. We start with the mainshock and recover ten aftershocks with the largest number of stations to produce an initial set of master events with the highest quality templates. Then we find all aftershocks in the REB and many additional events, which were not originally found by the IDC. Using all events found after the first iteration as master events we find new events, which are also used in the next iteration. The iterative process stops when no new events can be found. In that sense the final set of aftershocks obtained with cross correlation is a comprehensive one.
Hasanpour, Neda; Attarbashi Moghadam, Behrouz; Sami, Ramin; Tavakol, Kamran
2016-08-01
The clinical COPD questionnaire (CCQ) has been developed to measure the health status of COPD patients. The aim of this study was to translate CCQ into the Persian language and assess the validity and reliability of the translated version. We used a forward-backward procedure to translate the questionnaire. In a cross-sectional study 100 COPD patients and 50 healthy subjects over 40 years old were selected to assess the reliability and construct validity of the instrument. The face and content validity were used for the questionnaire validity. Validity was examined in a population of patients with COPD, using the Persian validated version of the St George's Respiratory Questionnaire (PSGRQ). In order to assess the questionnaire's reliability, the Intraclass correlation coefficient (ICC) and Cronbach's alpha were calculated. Test-retest reliability was tested by re-administering the Persian version of the CCQ (PCCQ) after 1 week. Test-retest carry out of data demonstrates that the PCCQ has excellent reliability (ICC for all 3 domains were higher than 0.9). Internal consistency was found by Cronbach's alpha to be 0.96, 0.94, 0.97, and 0.98 for the symptom, mental state, functional state and total scores respectively. In addition, the correlation between the components of PCCQ and PSGRQ showed satisfactory construct validity. Analyzing the data from healthy subjects and patients divulged that the PCCQ has acceptable discriminant validity. In general, the PCCQ had satisfactory reliability and validity for assessing health-related quality of life status of Iranian COPD patients.
Joshi, Veena D; Mooppil, Nandakumar; Lim, Jeremy Fy
2010-12-20
In Singapore, the prevalence of end-stage renal disease (ESRD) and the number of people on dialysis is increasing. The impact of ESRD on patient quality of life has been recognized as an important outcome measure. The Kidney Disease Quality Of Life-Short Form (KDQOL-SF™) has been validated and is widely used as a measure of quality of life in dialysis patients in many countries, but not in Singapore. We aimed to determine the reliability and validity of the KDQOL-SF™ for haemodialysis patients in Singapore. From December 2006 through January 2007, this cross-sectional study gathered data on patients ≥21 years old, who were undergoing haemodialysis at National Kidney Foundation in Singapore. We used exploratory factor analysis to determine construct validity of the eight KDQOL-SF™ sub-scales, Cronbach's alpha coefficient to determine internal consistency reliability, correlation of the overall health rating with kidney disease-targeted scales to confirm validity, and correlation of the eight sub-scales with age, income and education to determine convergent and divergent validity. Of 1980 haemodialysis patients, 1180 (59%) completed the KDQOL-SF™. Full information was available for 980 participants, with a mean age of 56 years. The sample was representative of the total dialysis population in Singapore, except Indian ethnicity that was over-represented. The instrument designers' proposed eight sub-scales were confirmed, which together accounted for 68.4% of the variance. All sub-scales had a Cronbach's α above the recommended minimum value of 0.7 to indicate good reliability (range: 0.72 to 0.95), except for Social function (0.66). Correlation of items within subscales was higher than correlation of items outside subscales in 90% of the cases. The overall health rating positively correlated with kidney disease-targeted scales, confirming validity. General health subscales were found to have significant associations with age, income and education, confirming convergent and divergent validity. The psychometric properties of the KDQOL-SF™ resulting from this first-time administration of the instrument support the validity and reliability of the KDQOL-SF™ as a measure of quality of life of haemodialysis patients in Singapore. It is, however, necessary to determine the test-retest reliability of the KDQOL-SF™ among the haemodialysis population of Singapore.
Systematic bias of correlation coefficient may explain negative accuracy of genomic prediction.
Zhou, Yao; Vales, M Isabel; Wang, Aoxue; Zhang, Zhiwu
2017-09-01
Accuracy of genomic prediction is commonly calculated as the Pearson correlation coefficient between the predicted and observed phenotypes in the inference population by using cross-validation analysis. More frequently than expected, significant negative accuracies of genomic prediction have been reported in genomic selection studies. These negative values are surprising, given that the minimum value for prediction accuracy should hover around zero when randomly permuted data sets are analyzed. We reviewed the two common approaches for calculating the Pearson correlation and hypothesized that these negative accuracy values reflect potential bias owing to artifacts caused by the mathematical formulas used to calculate prediction accuracy. The first approach, Instant accuracy, calculates correlations for each fold and reports prediction accuracy as the mean of correlations across fold. The other approach, Hold accuracy, predicts all phenotypes in all fold and calculates correlation between the observed and predicted phenotypes at the end of the cross-validation process. Using simulated and real data, we demonstrated that our hypothesis is true. Both approaches are biased downward under certain conditions. The biases become larger when more fold are employed and when the expected accuracy is low. The bias of Instant accuracy can be corrected using a modified formula. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Scanlan, Justin Newton; Hancock, Nicola; Honey, Anne
2018-03-01
There is a need for robust outcome measures for use in psychiatric services. Particularly lacking are self-rated recovery measures with evidence of sensitivity to change. This study was established to examine the convergent validity and sensitivity to change over time (responsiveness) of the Recovery Assessment Scale - Domains and Stages (RAS-DS), in comparison to level of unmet need as measured by the Camberwell Assessment of Need - Short Appraisal Scale (CANSAS). Convergent validity was examined through cross-sectional correlations between 540 CANSAS and RAS-DS scores collected on the same day for the same individuals. Sensitivity to change was examined using correlations between change scores in CANSAS and RAS-DS where both were collected on the same day and the two time points were separated by 90 days or more (n = 498). Results demonstrated moderate, significant cross-sectional correlations between CANSAS scores and RAS-DS total and domain scores and between change scores of both instruments. Results suggest that the RAS-DS is sensitive enough to detect change over time. Only moderate correlation between the RAS-DS and CANSAS suggests that, in the context of recovery-oriented service provision, it is important to measure self-reported recovery in addition to level of unmet needs. Copyright © 2018 Elsevier B.V. All rights reserved.
Bermúdez-de-Alvear, Rosa M; Gálvez-Ruiz, Pablo; Martínez-Arquero, A Ginés; Rando-Márquez, Sara; Fernández-Contreras, Elena
2018-06-11
This study aimed to analyze the psychometric properties of the Spanish version of the Voice Activity and Participation Profile (SVAPP) questionnaire. A randomized, cross-sectional sampling strategy with controls was used. Two samples with a total of 169 participants were analyzed, specifically 61 men (mean age 37.02) and 108 women (mean age 37.78). Of these participants, 112 were patients and 57 were controls. The instrument was submitted to reliability (internal consistency and corrected item-total correlations) and reproducibility analyses. Validation assessment was based on the construct validity, convergent validity, discriminant validity, and concurrent validity. The global internal consistency was excellent (Cronbach's α = 0.976), corrected item-total correlations were satisfactory and ranged 0.63-0.89, and factor loadings were above 0.50. The different subscales showed good internal consistency (alpha coefficients ranged 0.830-0.956) and test-retest values were consistently associated. The exploratory factor analysis evidenced a strongly defined five factors internal structure, with factors loadings ranging 0.51-0.86. Convergent validity demonstrated that all subscales and scores were very strongly correlated (Pearson r above 0.735) and significantly associated. The discriminant validity analysis showed that SVAPP had good specificity to distinguish dysphonic from healthy voice subjects. Concurrent validity with Voice Handicap Index Spanish version (SVHI) showed very strong correlations between total scores, and between SVHI total score and SVAPP Daily and Social Communication subscales; correlations between both tests subscales were strong; only between SVAPP Work and SVHI Physical sections correlations were moderate. The findings of the present study demonstrated evidence for the SVAPP questionnaire reliability and validity, and provided insightful implications of voice disorders on Spanish patients' quality of life. However, further investigations are required. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Cross-cultural adaptation of an Arabic version of the 10-item hearing handicap inventory.
Weinstein, Barbara E; Rasheedy, Doha; Taha, Hend M; Fatouh, Fathy N
2015-05-01
The purpose of this study was to translate and culturally adapt an Arabic version of the hearing handicap inventory for the elderly - screening (HHIE-S). The HHIE-S was translated following cross-cultural adaptation guidelines, and pretested in 20 elderly patients with hearing impairment. Next, the adapted Arabic HHIE-S underwent psychometric evaluation. The results were confirmed by pure-tone audiometer (PTA) examination. The patients completed the HHIE-S again after one hour. The validation of the questionnaire using Cronbach's alpha (internal consistency), (construct validity), and intraclass correlation coefficients (repeatability) was performed. Twenty elderly subjects with hearing impairment were recruited for the pretesting stage, and 100 elderly subjects were recruited for the psychometric evaluation stage. Patients with acute illness, functional dependency, cognitive impairment, and previous users of hearing aids were excluded. The adapted Arabic HHIE-S showed good internal consistency (α = 0.902). Construct validity was good, as high correlations were found between the scale and the PTA outcome (r = 0.688, p = 0.000). Repeatability was high (ICC = 0.986). This study showed that the adapted Arabic HHIE-S is a valid and reliable questionnaire for the assessment of handicapping hearing impairment in Egyptian elderly patients.
Doubova, Svetlana V; Aguirre-Hernandez, Rebeca; Infante-Castañeda, Claudia; Martinez-Vega, Ingrid; Pérez-Cuevas, Ricardo
2015-10-01
The purpose of this study was to validate the Mexican version of the Support Person Unmet Needs Survey (SPUNS-SFM). A cross-sectional survey that included 826 primary caregivers of cancer patients was conducted from June to December 2013 at the Oncology Hospital of the Mexican Institute of Social Security in Mexico City. The validation procedure comprised (1) content validity through a group of experts; (2) construct validity through an exploratory factor analysis based on the polychoric correlation matrix; (3) internal consistency using Cronbach's alpha; (4) convergent validity between SPUNS-SFM and quality of life, anxiety-and-depression scales by calculating Spearman's rank correlation coefficient;( 5) discriminative validity through the Wilcoxon rank-sum test; and (6) test-retest reliability using intraclass correlation coefficient. SPUNS-SFM has 23 items with six factors accounting for 65 % of the total variance. The domains were concerns about the future, access and continuity of healthcare, information, work and finance, and personal and emotional needs. Cronbach's alpha values ranged from 0.70 to 0.88 among factors. SPUNS-SFM had moderate convergent validity compared with quality of life and depression-and-anxiety scales and good discriminative validity, revealing high needs for younger caregivers and more emotional needs for caregivers of patients with advanced cancer stages. Intraclass correlation coefficient between SPUNS-SFM measurements was 0.78. SPUNS-SFM is a valid and reliable tool to identify needs of caregivers of cancer patients.
González-Sánchez, Manuel; Ruiz-Muñoz, Maria; Li, Guang Zhi; Cuesta-Vargas, Antonio I
2018-08-01
To perform a cross-cultural adaptation and validation of the Foot Function Index (FFI) questionnaire to develop the Chinese version. Three hundred and six patients with foot and ankle neuromusculoskeletal diseases participated in this observational study. Construct validity, internal consistency and criterion validity were calculated for the FFI Chinese version after the translation and transcultural adaptation process. Internal consistency ranged from 0.996 to 0.998. Test-retest analysis ranged from 0.985 to 0.994; minimal detectable change 90: 2.270; standard error of measurement: 0.973. Load distribution of the three factors had an eigenvalue greater than 1. Chi-square value was 9738.14 (p < 0.001). Correlations with the three factors were significant between Factor 1 and the other two: r = -0.634 (Factor 2) and r = -0.191 (Factor 1). Foot Function Index (Taiwan Version), Short-Form 12 (Version 2) and EuroQol-5D were used for criterion validity. Factors 1 and 2 showed significant correlation with 15/16 and 14/16 scales and subscales, respectively. Foot Function Index Chinese version psychometric characteristics were good to excellent. Chinese researchers and clinicians may use this tool for foot and ankle assessment and monitoring. Implications for rehabilitation A cross-cultural adaptation of the FFI has been done from original version to Chinese. Consistent results and satisfactory psychometric properties of the Foot Function Index Chinese version have been reported. For Chinese speaking researcher and clinician FFI-Ch could be used as a tool to assess patients with foot disease.
Cui, Jin; Jia, Zhenyu; Zhi, Xin; Li, Xiaoqun; Zhai, Xiao; Cao, Liehu; Weng, Weizong; Zhang, Jun; Wang, Lin; Chen, Xiao; Su, Jiacan
2017-01-05
The Achilles tendon Total Rupture Score (ATRS), which is originally developed in 2007 in Swedish, is the only patient-reported outcome measure (PROM) for specific outcome assessment of an Achilles tendon rupture.Purpose of this study is to translate and cross-culturally adapt Achilles tendon Total Rupture Score (ATRS) into simplified Chinese, and primarily evaluate the responsiveness, reliability and validity. International recognized guideline which was designed by Beaton was followed to make the translation of ATRS from English into simplified Chinese version (CH-ATRS). A prospective cohort study was carried out for the cross-cultural adaptation. There were 112 participants included into the study. Psychometric properties including floor and ceiling effects, Cronbach's alpha, intraclass correlation coefficient, effect size, standard response mean, and construct validity were tested. The mean scores of CH-ATRS are 57.42 ± 13.70. No sign of floor or ceiling effect was found of CH-ATRS. High level of internal consistency was supported by the value of Cronbach's alpha (0.893). ICC (0.979, 95%CI: 0.984-0.993) was high to indicate the high test-retest reliability. Great responsive ness was proved with the high absolute value of ES and SRM (0.84 and 8.98, respectively). The total CH-ATRS score had very good correlation with physical function and body pain subscales of SF-36 (r = -0.758 and r = -0.694, respectively, p < 0.001), while poor correlation with vitality and role physical subscales of SF-36 (r = -0.033 and r = -0.025, respectively, p ≥ 0.05), which supported construct validity of CH-ATRS. This Chinese version of Achilles tendon Total Rupture Score (CH-ATRS) can be used as a reliable and valid instrument for Achilles tendon rupture assessing in Chinese-speaking population. Level of evidence II.
Longo Imedio, Isabel; Serra-Guillén, Carlos
2016-01-01
While there are questionnaires for evaluating the effects of skin cancer on patient quality of life, there are no specific questionnaires available in Spanish for evaluating quality of life in patients with actinic keratosis. The aim of this study was to translate and culturally adapt the Actinic Keratosis Quality of Life (AKQoL) questionnaire into Spanish. The original questionnaire was translated into Spanish following the guidelines for the cross-cultural adaptation of self-report measures. Several measures of general reliability and validity were calculated, including Cronbach α for internal consistency and the Spearman rank-order correlation coefficient and a Bland-Altman plot for test-retest reliability. To test concurrent validity, we used the Pearson correlation coefficient to measure the correlation between AKQoL and Skindex-29 scores. The final version of the questionnaire was administered to 621 patients with actinic keratosis, who scored a mean (SD) of 5.25 (4.73) points (total possible score, 0-25). The Cronbach α reliability coefficient analysis was 0.84. The correlation between the mean (SD) score on the Skindex-29 (1.87 [4.07]) and on the AKQoL (1.97 [2.98] was 0.344 (P=.002, Spearman's rho), with a proportion of shared variance of 11.8%. The translation, cross-cultural adaptation, and validation of the original AKQoL produced a reliable, easily understandable questionnaire for evaluating the impact of actinic keratosis on the quality of life of patients in our setting. Copyright © 2016 AEDV. Published by Elsevier España, S.L.U. All rights reserved.
Medin, Anine Christine; Carlsen, Monica Hauger; Andersen, Lene Frost
2016-12-01
To validate estimated intakes of carotenoid-rich foods from a web-based food recall (WebFR) using carotenoids in blood as an objective reference method. Cross-sectional validation study using carotenoids in plasma to evaluate estimated intakes of selected carotenoid-rich foods. Participants recorded their food intake in the WebFR and plasma concentrations of β-carotene, α-carotene, β-cryptoxanthin, lycopene, lutein and zeaxanthin were measured. Schools and homes of families in a suburb of the capital of Norway. A total of 261 participants in the age groups 8-9 and 12-14 years. Spearman's rank correlation coefficients ranged from 0·30 to 0·44, and cross-classification showed that 71·6-76·6 % of the participants were correctly classified, when comparing the reported intakes of carotenoid-rich foods and concentrations of the corresponding carotenoids in plasma, not including lutein and zeaxanthin. Correlations were acceptable and cross-classification analyses demonstrated that the WebFR was able to rank participants according to their reported intake of foods rich in α-carotene, β-carotene, β-cryptoxanthin and lycopene. The WebFR is a promising tool for dietary assessment among children and adolescents.
Sparse brain network using penalized linear regression
NASA Astrophysics Data System (ADS)
Lee, Hyekyoung; Lee, Dong Soo; Kang, Hyejin; Kim, Boong-Nyun; Chung, Moo K.
2011-03-01
Sparse partial correlation is a useful connectivity measure for brain networks when it is difficult to compute the exact partial correlation in the small-n large-p setting. In this paper, we formulate the problem of estimating partial correlation as a sparse linear regression with a l1-norm penalty. The method is applied to brain network consisting of parcellated regions of interest (ROIs), which are obtained from FDG-PET images of the autism spectrum disorder (ASD) children and the pediatric control (PedCon) subjects. To validate the results, we check their reproducibilities of the obtained brain networks by the leave-one-out cross validation and compare the clustered structures derived from the brain networks of ASD and PedCon.
Chabrera, Carolina; Areal, Joan; Font, Albert; Caro, Mónica; Bonet, Marta; Zabalegui, Adelaida
2015-01-01
The aim of this study is to develop a Spanish version of the Satisfaction With Decision scale (SWDs) and analyse the psychometric properties of validity and reliability. An observational, descriptive study and validation of a tool to measure satisfaction with the decision. Urology, Radiation oncology, and Medical oncology Departments of the Hospital Universitari Germans Trias i Pujol, Institut Català d'Oncologia and the Institut Oncològic del Vallès - Hospital General de Catalunya. A total of 170 participants diagnosed with prostate cancer, and who could read and write in Spanish and gave their informed consent. A translation, back-translation and cross-cultural adaptation to Spanish was performed on the SWDs. The content validity, criterion validity, construct validity and reliability (internal consistency and stability) of the Spanish version were evaluated. The SWDs contains 6 items with 5-item Likert scales. A Spanish version (ESD) was obtained that was linguistically and conceptually equivalent to the original version. Criterion validity, the ESD correlated with "satisfaction with the decision" using a linear analogue scale, was significant (r=0.63, P<.01) for all items. The factorial analysis showed a unique dimension to explain 82.08% of the variance. The ESD showed excellent results in terms of internal consistency (Cronbach alpha=0.95) and good test-retest reliability with intraclass correlation coefficient of 0.711. The ESD is a validated Spanish scale to measure the satisfaction with the decisions taken in health, and demonstrates a correct validity and reliability. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.
Angers, Magalie; Svotelis, Amy; Balg, Frederic; Allard, Jean-Pascal
2016-04-01
The Ankle Osteoarthritis Scale (AOS) is a self-administered score specific for ankle osteoarthritis (OA) with excellent reliability and strong construct and criterion validity. Many recent randomized multicentre trials have used the AOS, and the involvement of the French-speaking population is limited by the absence of a French version. Our goal was to develop a French version and validate the psychometric properties to assure equivalence to the original English version. Translation was performed according to American Association of Orthopaedic Surgeons (AAOS) 2000 guidelines for cross-cultural adaptation. Similar to the validation process of the English AOS, we evaluated the psychometric properties of the French version (AOS-Fr): criterion validity (AOS-Fr v. Western Ontario and McMaster Universities Arthritis Index [WOMAC] and SF-36 scores), construct validity (AOS-Fr correlation to single heel-lift test), and reliability (AOS-Fr test-retest). Sixty healthy individuals tested a prefinal version of the AOS-Fr for comprehension, leading to modifications and a final version that was approved by C. Saltzman, author of the AOS. We then recruited patients with ankle OA for evaluation of the AOS-Fr psychometric properties. Twenty-eight patients with ankle OA participated in the evaluation. The AOS-Fr showed strong criterion validity (AOS:WOMAC r = 0.709 and AOS:SF-36 r = -0.654) and construct validity (r = 0.664) and proved to be reliable (test-retest intraclass correlation coefficient = 0.922). The AOS-Fr is a reliable and valid score equivalent to the English version in terms of psychometric properties, thus is available for use in multicentre trials.
NASA Astrophysics Data System (ADS)
Nolet, G.; Mercerat, D.; Zaroli, C.
2012-12-01
We present the first complete test of finite frequency tomography with banana-doughnut kernels, from the generation of seismograms in a 3D model to the final inversion, and are able to lay to rest all of the so-called `controversies' that have slowed down its adoption. Cross-correlation delay times are influenced by energy arriving in a time window that includes later arrivals, either scattered from, or diffracted around lateral heterogeneities. We present here the results of a 3D test in which we generate 1716 seismograms using the spectral element method in a cross-borehole experiment conducted in a checkerboard box. Delays are determined for the broadband signals as well as for five frequency bands (each one octave apart) by cross-correlating seismograms for a homogeneous pattern with those for a checkerboard. The large (10 per cent) velocity contrast and the regularity of the checkerboard pattern causes severe reverberations that arrive late in the cross-correlation window. Data errors are estimated by comparing linearity between delays measured for a model with 10 per cent velocity contrast with those with a 4 per cent contrast. Sensitivity kernels are efficiently computed with ray theory using the `banana-doughnut' kernels from Dahlen et al. (GJI 141:157, 2000). The model resulting from the inversion with a data fit with reduced χ2red=1 shows an excellent correspondence with the input model and allows for a complete validation of the theory. Amplitudes in the (well resolved) top part of the model are close to the input amplitudes. Comparing a model derived from one band only shows the power of using multiple frequency bands in resolving detail - essentially the observed dispersion captures some of the waveform information. Finite frequency theory also allows us to image the checkerboard at some distance from the borehole plane. Most disconcertingly for advocates of ray theory are the results obtained when we interpret cross-correlation delays with ray theory. We shall present an extreme case of the devil's checkerboard (the term is from Jacobsen and Sigloch), in which the sign of the anomalies in the checkerboard is reversed in the ray-theoretical solution, a clear demonstration of the reality of effects of the doughnut hole. We conclude that the test fully validates `banana-doughnut' theory, and disqualifies ray theoretical inversions of cross-correlation delays.
Machado, Roberta Ismael Lacerda; Souto, Lais Medeiros; Freire, Eutilia Andrade Medeiros
2014-01-01
Systemic sclerosis (SSc) is a multisystem disease, autoimmune disorder characterized by a fibroblastic disfunction, with significant impact on quality of life (QoL), measured by instruments or questionnaires that usually were formulated in other languages and in different cultural contexts. Translate into Brazilian Portuguese, cross cultural adaptation and assess the reliability and validity of the Systemic Sclerosis Questionnaire (SySQ). Translation and adaptation: into Portuguese and cross-cultural adaptation was performed in accordance with studies on questionnaire translation methodology into other languages. Reliability: it was analyzed using three interviews with different interviewers, two on the same day (interobserver) and the third within 14 days of the first assessment (intraobserver).Validity was assessed by correlating clinical and quality of life parameters with the domain scores of Sysc. a descriptive analysis of the study sample. Reproducibility was assessed using an intraclass correlation coefficient (ICC). Internal consistency was assessed using Cronbach's alpha coefficient. To assess validity we used Spearman correlation coefficient. Five percent was the level of significance adopted for all statistical tests. In the evaluation of the questionnaires, the results were similar to the original questionnaire, the internal consistency ranging between 0.73 and 0.93 for each item. The interobserver reproducibility was very good for all domains (α = 0.786 to 0.983) and intraobserver agreement was considered very good for general symptoms domain (ICC = 0.916), good for musculoskeletal symptoms domain (ICC = 0.897) and cardiopulmonary domain (ICC = 0.842) and reasonable for gastrointestinal symptoms domain (ICC = 0.686). The Brazilian Portuguese version of SySQ proved to be reproducible and valid for our population, using a recognized methodology for translation and cultural adaptation of questionnaires, as well as to assess the reproducibility and validity.
Ferreira, Mariana Cândido; Björklund, Martin; Dach, Fabiola; Chaves, Thais Cristina
The purpose of this study was to adapt and evaluate the psychometric properties of the ProFitMap-neck to Brazilian Portuguese. The cross-cultural adaptation consisted of 5 stages, and 180 female patients with chronic neck pain participated in the study. A subsample (n = 30) answered the pretest, and another subsample (n = 100) answered the questionnaire a second time. Internal consistency, test-retest reliability, and construct validity (hypothesis testing and structural validity) were estimated. For construct validity, the scores of the questionnaire were correlated with the Neck Disability Index (NDI), and the Hospital Anxiety and Depression Scale (HADS), the Tampa Scale of Kinesiophobia (TSK), and the 36-item Short-Form Health Survey (SF-36). Internal consistency was determined by adequate Cronbach's α values (α > 0.70). Strong reliability was identified by high intraclass correlation coefficients (ICC > 0.75). Construct validity was identified by moderate and strong correlations of the Br-ProFitMap-neck with total NDI score (-0.56
Assessing behavioural changes in ALS: cross-validation of ALS-specific measures.
Pinto-Grau, Marta; Costello, Emmet; O'Connor, Sarah; Elamin, Marwa; Burke, Tom; Heverin, Mark; Pender, Niall; Hardiman, Orla
2017-07-01
The Beaumont Behavioural Inventory (BBI) is a behavioural proxy report for the assessment of behavioural changes in ALS. This tool has been validated against the FrSBe, a non-ALS-specific behavioural assessment, and further comparison of the BBI against a disease-specific tool was considered. This study cross-validates the BBI against the ALS-FTD-Q. Sixty ALS patients, 8% also meeting criteria for FTD, were recruited. All patients were evaluated using the BBI and the ALS-FTD-Q, completed by a carer. Correlational analysis was performed to assess construct validity. Precision, sensitivity, specificity, and overall accuracy of the BBI when compared to the ALS-FTD-Q, were obtained. The mean score of the whole sample on the BBI was 11.45 ± 13.06. ALS-FTD patients scored significantly higher than non-demented ALS patients (31.6 ± 14.64, 9.62 ± 11.38; p < 0.0001). A significant large positive correlation between the BBI and the ALS-FTD-Q was observed (r = 0.807, p < 0.0001), and no significant correlations between the BBI and other clinical/demographic characteristics indicate good convergent and discriminant validity, respectively. 72% of overall concordance was observed. Precision, sensitivity, and specificity for the classification of severely impaired patients were adequate. However, lower concordance in the classification of mild behavioural changes was observed, with higher sensitivity using the BBI, most likely secondary to BBI items which endorsed behavioural aspects not measured by the ALS-FTD-Q. Good construct validity has been further confirmed when the BBI is compared to an ALS-specific tool. Furthermore, the BBI is a more comprehensive behavioural assessment for ALS, as it measures the whole behavioural spectrum in this condition.
Chaimongkol, Nujjaree N; Flick, Louise H
2006-01-01
The purpose of this study was to examine the psychometric properties of Thai versions of the Maternal Behavior Q-Sort (MBQS), Caldwell's HOME, and the Attachment Q-set (AQS). A sample of 110 Thai mother-infant dyads were studied. The Content Validity Index (CVIs) of the Thai MBQS, HOME and AQS were between 91% and 99%. Internal consistency of the HOME was .71. Interobserver reliability of the MBQS, HOME, and AQS were .95, .87, and .87, respectively. Convergent validity was supported by finding a positive correlation between the MBQS and the HOME (r = .29, p < .001). A positive correlation of .45 (p < .001) between the scores of the MBQS and the AQS indicated concurrent validity of these scales. Study findings indicate the Thai MBQS, HOME, and AQS are reliable and valid in this Thai sample and suggest that the Thai versions reflect concepts similar to those in the original English versions.
Price-volume multifractal analysis and its application in Chinese stock markets
NASA Astrophysics Data System (ADS)
Yuan, Ying; Zhuang, Xin-tian; Liu, Zhi-ying
2012-06-01
An empirical research on Chinese stock markets is conducted using statistical tools. First, the multifractality of stock price return series, ri(ri=ln(Pt+1)-ln(Pt)) and trading volume variation series, vi(vi=ln(Vt+1)-ln(Vt)) is confirmed using multifractal detrended fluctuation analysis. Furthermore, a multifractal detrended cross-correlation analysis between stock price return and trading volume variation in Chinese stock markets is also conducted. It is shown that the cross relationship between them is also found to be multifractal. Second, the cross-correlation between stock price Pi and trading volume Vi is empirically studied using cross-correlation function and detrended cross-correlation analysis. It is found that both Shanghai stock market and Shenzhen stock market show pronounced long-range cross-correlations between stock price and trading volume. Third, a composite index R based on price and trading volume is introduced. Compared with stock price return series ri and trading volume variation series vi, R variation series not only remain the characteristics of original series but also demonstrate the relative correlation between stock price and trading volume. Finally, we analyze the multifractal characteristics of R variation series before and after three financial events in China (namely, Price Limits, Reform of Non-tradable Shares and financial crisis in 2008) in the whole period of sample to study the changes of stock market fluctuation and financial risk. It is found that the empirical results verified the validity of R.
Turner, Nigel E; Elton-Marshall, Tara; Shi, Jing; Wiebe, Jamie; Boak, Angela; van der Maas, Mark; Mann, Robert E
2018-06-01
This paper reports on the cross validation of the Gambling Problem Severity Subscale of the Canadian Adolescent Gambling Index (CAGI/GPSS). The CAGI/GPSS was included in a large school based drug use and health survey conducted in 2015. Data from students in grades 9-12 (ages 13-20 years) derived from the (N = 3369 students). The CAGI/GPSS produced an alpha of 0.789. A principle component analysis revealed two eigenvalues greater than one. An oblique rotation revealed these components to represent consequences and over involvement. The CAGI/GPSS indicated that 1% of the students fell into the "red" category indicating a severe problem and an additional 3.3% scored in the "yellow" category indicating low to moderate problems. The CAGI/GPSS was shown to be significantly correlated with gambling frequency (r = 0.36), largest expenditure (r = 0.37), sex (more likely to be male) (r = -0.19), lower school marks (r = -0.07), hazardous drinking, (r = 0.16), problem video game play (r = 0.16), as well as substance abuse. The CAGI/GPSS was cross validated using a shorted version of the short SOGS, r = 0.48. In addition the CAGI/GPSS and short SOGS produced very similar patterns of correlations results. The results support the validity and reliability of the CAGI/GPSS as a measure of gambling problems among adolescents.
Jean-Pierre, Pascal; Fundakowski, Christopher; Perez, Enrique; Jean-Pierre, Shadae E; Jean-Pierre, Ashley R; Melillo, Angelica B; Libby, Rachel; Sargi, Zoukaa
2013-02-01
Cancer and its treatments are associated with psychological distress that can negatively impact self-perception, psychosocial functioning, and quality of life. Patients with head and neck cancers (HNC) are particularly susceptible to psychological distress. This study involved a cross-validation of the Measure of Body Apperception (MBA) for HNC patients. One hundred and twenty-two English-fluent HNC patients between 20 and 88 years of age completed the MBA on a Likert scale ranging from "1 = disagree" to "4 = agree." We assessed the latent structure and internal consistency reliability of the MBA using Principal Components Analysis (PCA) and Cronbach's coefficient alpha (α), respectively. We determined convergent and divergent validities of the MBA using correlations with the Hospital Anxiety and Depression Scale (HADS), observer disfigurement rating, and patients' clinical and demographic variables. The PCA revealed a coherent set of items that explained 38 % of the variance. The Kaiser-Meyer-Olkin measure of sampling adequacy was 0.73 and the Bartlett's test of sphericity was statistically significant (χ (2) (28) = 253.64; p < 0.001), confirming the suitability of the data for dimension reduction analysis. The MBA had good internal consistency reliability (α = 0.77) and demonstrated adequate convergent and divergent validities based on statistically significant moderate correlations with the HADS (p < 0.01) and observer rating of disfigurement (p < 0.026) and nonstatistically significant correlations with patients' clinical and demographic variables: tumor location, age at diagnosis, and birth place (all p (s) > 0.05). The MBA is a valid and reliable screening measure of body apperception for HNC patients.
Validation of the Regicor Short Physical Activity Questionnaire for the Adult Population
Molina, Luis; Sarmiento, Manuel; Peñafiel, Judith; Donaire, David; Garcia-Aymerich, Judith; Gomez, Miquel; Ble, Mireia; Ruiz, Sonia; Frances, Albert; Schröder, Helmut; Marrugat, Jaume; Elosua, Roberto
2017-01-01
Objective To develop and validate a short questionnaire to estimate physical activity (PA) practice and sedentary behavior for the adult population. Methods The short questionnaire was developed using data from a cross-sectional population-based survey (n = 6352) that included the Minnesota leisure-time PA questionnaire. Activities that explained a significant proportion of the variability of population PA practice were identified. Validation of the short questionnaire included a cross-sectional component to assess validity with respect to the data collected by accelerometers and a longitudinal component to assess reliability and sensitivity to detect changes (n = 114, aged 35 to 74 years). Results Six types of activities that accounted for 87% of population variability in PA estimated with the Minnesota questionnaire were selected. The short questionnaire estimates energy expenditure in total PA and by intensity (light, moderate, vigorous), and includes 2 questions about sedentary behavior and a question about occupational PA. The short questionnaire showed high reliability, with intraclass correlation coefficients ranging between 0.79 to 0.95. The Spearman correlation coefficients between estimated energy expenditure obtained with the questionnaire and the number of steps detected by the accelerometer were as follows: 0.36 for total PA, 0.40 for moderate intensity, and 0.26 for vigorous intensity. The questionnaire was sensitive to detect changes in moderate and vigorous PA (correlation coefficients ranging from 0.26 to 0.34). Conclusion The REGICOR short questionnaire is reliable, valid, and sensitive to detect changes in moderate and vigorous PA. This questionnaire could be used in daily clinical practice and epidemiological studies. PMID:28085886
Del Castillo, Letícia Nunes Carreras; Leporace, Gustavo; Cardinot, Themis Moura; Levy, Roger Abramino; Oliveira, Liszt Palmeira de
2013-01-01
CONTEXT AND OBJECTIVE The Nonarthritic Hip Score (NAHS) is a clinical evaluation questionnaire that was developed in the English language to evaluate hip function in young and physically active patients. The aims of this study were to translate this questionnaire into the Brazilian Portuguese language, to adapt it to Brazilian culture and to validate it. DESIGN AND SETTING Cohort study conducted between 2008 and 2010, at Universidade do Estado do Rio de Janeiro (UERJ). METHODS Questions about physical activities and household chores were modified to better fit Brazilian culture. Reproducibility, internal consistency and validity (correlations with the Algofunctional Lequesne Index and the Western Ontario and McMaster Universities Arthritis Index [WOMAC]) were tested. The NAHS-Brazil, Lequesne and WOMAC questionnaires were applied to 64 young and physically active patients (mean age, 40.9 years; 31 women). RESULTS The intraclass correlation coefficient (which measures reproducibility) was 0.837 (P < 0.001). Bland-Altman plots revealed a mean error in the difference between the two measurements of 0.42. The internal consistency was confirmed through a Cronbach alpha of 0.944. The validity between NAHS-Brazil and Lequesne and between NAHS-Brazil and WOMAC showed high correlations, r = 0.7340 and r = 0.9073, respectively. NAHS-Brazil showed good validity with no floor or ceiling effects. CONCLUSION The NAHS was translated into the Brazilian Portuguese language and was cross-culturally adapted to Brazilian culture. It was shown to be a useful tool in clinical practice for assessing the quality of life of young and physically active patients with hip pain.
The reliability and validity of the SF-8 with a conflict-affected population in northern Uganda.
Roberts, Bayard; Browne, John; Ocaka, Kaducu Felix; Oyok, Thomas; Sondorp, Egbert
2008-12-02
The SF-8 is a health-related quality of life instrument that could provide a useful means of assessing general physical and mental health amongst populations affected by conflict. The purpose of this study was to test the validity and reliability of the SF-8 with a conflict-affected population in northern Uganda. A cross-sectional multi-staged, random cluster survey was conducted with 1206 adults in camps for internally displaced persons in Gulu and Amuru districts of northern Uganda. Data quality was assessed by analysing the number of incomplete responses to SF-8 items. Response distribution was analysed using aggregate endorsement frequency. Test-retest reliability was assessed in a separate smaller survey using the intraclass correlation test. Construct validity was measured using principal component analysis, and the Pearson Correlation test for item-summary score correlation and inter-instrument correlations. Known groups validity was assessed using a two sample t-test to evaluates the ability of the SF-8 to discriminate between groups known to have, and not have, physical and mental health problems. The SF-8 showed excellent data quality. It showed acceptable item response distribution based upon analysis of aggregate endorsement frequencies. Test-retest showed a good intraclass correlation of 0.61 for PCS and 0.68 for MCS. The principal component analysis indicated strong construct validity and concurred with the results of the validity tests by the SF-8 developers. The SF-8 also showed strong construct validity between the 8 items and PCS and MCS summary score, moderate inter-instrument validity, and strong known groups validity. This study provides evidence on the reliability and validity of the SF-8 amongst IDPs in northern Uganda.
The reliability and validity of the SF-8 with a conflict-affected population in northern Uganda
Roberts, Bayard; Browne, John; Ocaka, Kaducu Felix; Oyok, Thomas; Sondorp, Egbert
2008-01-01
Background The SF-8 is a health-related quality of life instrument that could provide a useful means of assessing general physical and mental health amongst populations affected by conflict. The purpose of this study was to test the validity and reliability of the SF-8 with a conflict-affected population in northern Uganda. Methods A cross-sectional multi-staged, random cluster survey was conducted with 1206 adults in camps for internally displaced persons in Gulu and Amuru districts of northern Uganda. Data quality was assessed by analysing the number of incomplete responses to SF-8 items. Response distribution was analysed using aggregate endorsement frequency. Test-retest reliability was assessed in a separate smaller survey using the intraclass correlation test. Construct validity was measured using principal component analysis, and the Pearson Correlation test for item-summary score correlation and inter-instrument correlations. Known groups validity was assessed using a two sample t-test to evaluates the ability of the SF-8 to discriminate between groups known to have, and not have, physical and mental health problems. Results The SF-8 showed excellent data quality. It showed acceptable item response distribution based upon analysis of aggregate endorsement frequencies. Test-retest showed a good intraclass correlation of 0.61 for PCS and 0.68 for MCS. The principal component analysis indicated strong construct validity and concurred with the results of the validity tests by the SF-8 developers. The SF-8 also showed strong construct validity between the 8 items and PCS and MCS summary score, moderate inter-instrument validity, and strong known groups validity. Conclusion This study provides evidence on the reliability and validity of the SF-8 amongst IDPs in northern Uganda. PMID:19055716
Arabic cross cultural adaptation and validation of the National Institutes of Health Stroke Scale.
Hussein, Haitham M; Abdel Moneim, Amr; Emara, Tamer; Abd-Elhamid, Yousry A; Salem, Haitham H; Abd-Allah, Foad; Farrag, Mohammad A; Tork, M Amir; Shalash, Ali S; Ezz El Dein, Khaled H; Osman, Gamaleldin; Georgy, Shady S; Ghali, Peter G; Lyden, Patrick D; Moustafa, Ramez R
2015-10-15
The National Institutes of Health Stroke Scale (NIHSS), the most commonly used tool to quantify neurological deficit in acute stroke, was initially developed in English. We present our experience in developing and validating an Arabic version of the NIHSS (arNIHSS). In 6months, 137 patients were recruited (mean age±standard deviation 62±12years; 48 women). For interrater agreement, weighted kappa value ranged from 0.36 to 0.66 and intraclass correlation coefficient (ICC) for the whole scale was excellent at 0.95 (95% confidence interval [CI] 0.94-0.97). For intrarater agreement, weighted kappa ranged from 0.52 to 1.0 and the ICC was 0.94 (95% CI 0.87-0.98). The construct validity of the arNIHSS is demonstrated by its correlation with the DWI-ASPECT and the 3months mRS score (Spearman correlation -0.46 and 0.58 respectively; P<0.001 for both). We developed and validated a culturally adapted Arabic version of the NIHSS. Further validation in other Arab countries is recommended. Copyright © 2015 Elsevier B.V. All rights reserved.
Calibration of the Dutch-Flemish PROMIS Pain Behavior item bank in patients with chronic pain.
Crins, M H P; Roorda, L D; Smits, N; de Vet, H C W; Westhovens, R; Cella, D; Cook, K F; Revicki, D; van Leeuwen, J; Boers, M; Dekker, J; Terwee, C B
2016-02-01
The aims of the current study were to calibrate the item parameters of the Dutch-Flemish PROMIS Pain Behavior item bank using a sample of Dutch patients with chronic pain and to evaluate cross-cultural validity between the Dutch-Flemish and the US PROMIS Pain Behavior item banks. Furthermore, reliability and construct validity of the Dutch-Flemish PROMIS Pain Behavior item bank were evaluated. The 39 items in the bank were completed by 1042 Dutch patients with chronic pain. To evaluate unidimensionality, a one-factor confirmatory factor analysis (CFA) was performed. A graded response model (GRM) was used to calibrate the items. To evaluate cross-cultural validity, Differential item functioning (DIF) for language (Dutch vs. English) was evaluated. Reliability of the item bank was also examined and construct validity was studied using several legacy instruments, e.g. the Roland Morris Disability Questionnaire. CFA supported the unidimensionality of the Dutch-Flemish PROMIS Pain Behavior item bank (CFI = 0.960, TLI = 0.958), the data also fit the GRM, and demonstrated good coverage across the pain behavior construct (threshold parameters range: -3.42 to 3.54). Analysis showed good cross-cultural validity (only six DIF items), reliability (Cronbach's α = 0.95) and construct validity (all correlations ≥0.53). The Dutch-Flemish PROMIS Pain Behavior item bank was found to have good cross-cultural validity, reliability and construct validity. The development of the Dutch-Flemish PROMIS Pain Behavior item bank will serve as the basis for Dutch-Flemish PROMIS short forms and computer adaptive testing (CAT). © 2015 European Pain Federation - EFIC®
Evidence of Validity for the Japanese Version of the Foot and Ankle Ability Measure
Uematsu, Daisuke; Suzuki, Hidetomo; Sasaki, Shogo; Nagano, Yasuharu; Shinozuka, Nobuyuki; Sunagawa, Norihiko; Fukubayashi, Toru
2015-01-01
Context: The Foot and Ankle Ability Measure (FAAM) is a valid, reliable, and self-reported outcome instrument for the foot and ankle region. Objective: To provide evidence for translation, cross-cultural adaptation, validity, and reliability of the Japanese version of the FAAM (FAAM-J). Design: Cross-sectional study. Setting: Collegiate athletic training/sports medicine clinical setting. Patients or Other Participants: Eighty-three collegiate athletes. Main Outcome Measure(s): All participants completed the Activities of Daily Living and Sports subscales of the FAAM-J and the Physical Functioning and Mental Health subscales of the Japanese version of the Short Form-36v2 (SF-36). Also, 19 participants (23%) whose conditions were expected to be stable completed another FAAM-J 2 to 6 days later for test-retest reliability. We analyzed the scores of those subscales for convergent and divergent validity, internal consistency, and test-retest reliability. Results: The Activities of Daily Living and Sports subscales of the FAAM-J had correlation coefficients of 0.86 and 0.75, respectively, with the Physical Functioning section of the SF-36 for convergent validity. For divergent validity, the correlation coefficients with Mental Health of the SF-36 were 0.29 and 0.27 for each subscale, respectively. Cronbach α for internal consistency was 0.99 for the Activities of Daily Living and 0.98 for the Sports subscale. A 95% confidence interval with a single measure was ±8.1 and ±14.0 points for each subscale. The test-retest reliability measures revealed intraclass correlation coefficient values of 0.87 for the Activities of Daily Living and 0.91 for the Sports subscales with minimal detectable changes of ±6.8 and ±13.7 for the respective subscales. Conclusions: The FAAM was successfully translated for a Japanese version, and the FAAM-J was adapted cross-culturally. Thus, the FAAM-J can be used as a self-reported outcome measure for Japanese-speaking individuals; however, the scores must be interpreted with caution, especially when applied to different populations and other types of injury than those included in this study. PMID:25310247
Optical sampling by laser cavity tuning.
Hochrein, Thomas; Wilk, Rafal; Mei, Michael; Holzwarth, Ronald; Krumbholz, Norman; Koch, Martin
2010-01-18
Most time-resolved optical experiments rely either on external mechanical delay lines or on two synchronized femtosecond lasers to achieve a defined temporal delay between two optical pulses. Here, we present a new method which does not require any external delay lines and uses only a single femtosecond laser. It is based on the cross-correlation of an optical pulse with a subsequent pulse from the same laser. Temporal delay between these two pulses is achieved by varying the repetition rate of the laser. We validate the new scheme by a comparison with a cross-correlation measurement carried out with a conventional mechanical delay line.
The Vocal Cord Dysfunction Questionnaire: Validity and Reliability of the Persian Version.
Ghaemi, Hamide; Khoddami, Seyyedeh Maryam; Soleymani, Zahra; Zandieh, Fariborz; Jalaie, Shohreh; Ahanchian, Hamid; Khadivi, Ehsan
2017-12-25
The aim of this study was to develop, validate, and assess the reliability of the Persian version of Vocal Cord Dysfunction Questionnaire (VCDQ P ). The study design was cross-sectional or cultural survey. Forty-four patients with vocal fold dysfunction (VFD) and 40 healthy volunteers were recruited for the study. To assess the content validity, the prefinal questions were given to 15 experts to comment on its essential. Ten patients with VFD rated the importance of VCDQ P in detecting face validity. Eighteen of the patients with VFD completed the VCDQ 1 week later for test-retest reliability. To detect absolute reliability, standard error of measurement and smallest detected change were calculated. Concurrent validity was assessed by completing the Persian Chronic Obstructive Pulmonary Disease (COPD) Assessment Test (CAT) by 34 patients with VFD. Discriminant validity was measured from 34 participants. The VCDQ was further validated by administering the questionnaire to 40 healthy volunteers. Validation of the VCDQ as a treatment outcome tool was conducted in 18 patients with VFD using pre- and posttreatment scores. The internal consistency was confirmed (Cronbach α = 0.78). The test-retest reliability was excellent (intraclass correlation coefficient = 0.97). The standard error of measurement and smallest detected change values were acceptable (0.39 and 1.08, respectively). There was a significant correlation between the VCDQ P and the CAT total scores (P < 0.05). Discriminative validity was significantly different. The VCDQ scores in patients with VFD before and after treatment was significantly different (P < 0.001). The VCDQ was cross-culturally adapted to Persian and demonstrated to be a valid and reliable self-administered questionnaire in Persian-speaking population. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Validating LES for Jet Aeroacoustics
NASA Technical Reports Server (NTRS)
Bridges, James; Wernet, Mark P.
2011-01-01
Engineers charged with making jet aircraft quieter have long dreamed of being able to see exactly how turbulent eddies produce sound and this dream is now coming true with the advent of large eddy simulation (LES). Two obvious challenges remain: validating the LES codes at the resolution required to see the fluid-acoustic coupling, and the interpretation of the massive datasets that are produced. This paper addresses the former, the use of advanced experimental techniques such as particle image velocimetry (PIV) and Raman and Rayleigh scattering, to validate the computer codes and procedures used to create LES solutions. This paper argues that the issue of accuracy of the experimental measurements be addressed by cross-facility and cross-disciplinary examination of modern datasets along with increased reporting of internal quality checks in PIV analysis. Further, it argues that the appropriate validation metrics for aeroacoustic applications are increasingly complicated statistics that have been shown in aeroacoustic theory to be critical to flow-generated sound, such as two-point space-time velocity correlations. A brief review of data sources available is presented along with examples illustrating cross-facility and internal quality checks required of the data before it should be accepted for validation of LES.
Testing alternative ground water models using cross-validation and other methods
Foglia, L.; Mehl, S.W.; Hill, M.C.; Perona, P.; Burlando, P.
2007-01-01
Many methods can be used to test alternative ground water models. Of concern in this work are methods able to (1) rank alternative models (also called model discrimination) and (2) identify observations important to parameter estimates and predictions (equivalent to the purpose served by some types of sensitivity analysis). Some of the measures investigated are computationally efficient; others are computationally demanding. The latter are generally needed to account for model nonlinearity. The efficient model discrimination methods investigated include the information criteria: the corrected Akaike information criterion, Bayesian information criterion, and generalized cross-validation. The efficient sensitivity analysis measures used are dimensionless scaled sensitivity (DSS), composite scaled sensitivity, and parameter correlation coefficient (PCC); the other statistics are DFBETAS, Cook's D, and observation-prediction statistic. Acronyms are explained in the introduction. Cross-validation (CV) is a computationally intensive nonlinear method that is used for both model discrimination and sensitivity analysis. The methods are tested using up to five alternative parsimoniously constructed models of the ground water system of the Maggia Valley in southern Switzerland. The alternative models differ in their representation of hydraulic conductivity. A new method for graphically representing CV and sensitivity analysis results for complex models is presented and used to evaluate the utility of the efficient statistics. The results indicate that for model selection, the information criteria produce similar results at much smaller computational cost than CV. For identifying important observations, the only obviously inferior linear measure is DSS; the poor performance was expected because DSS does not include the effects of parameter correlation and PCC reveals large parameter correlations. ?? 2007 National Ground Water Association.
Development of the Persian version of the Vertigo Symptom Scale: Validity and reliability
Kamalvand, Atefeh; Ghahraman, Mansoureh Adel; Jalaie, Shohreh
2017-01-01
Background: Vertigo Symptom Scale (VSS) is a proper instrument for assessing the patient status, clarifying the symptoms, and examining the relative impact of the vertigo and anxiety on reported handicap. Our aim is the translation and cross-cultural adaptation of the VSS into Persian language (VSS-P) and investigating its validity and reliability in patients with peripheral vestibular disorders. Materials and Methods: VSS was translated into Persian. Cross-cultural adaptation was carried out on 101 patients with peripheral vestibular disorders and 34 participants with no history of vertigo. They completed the Persian versions of VSS, dizziness handicap inventory (DHI), and Beck anxiety inventory (BAI). Internal, discriminant, and convergent validities, internal consistency, and test-retest reliability were determined. Results: The VSS-P showed good face validity. Internal validity was confirmed and demonstrated the presence of two vertigo (VSS-VER) and autonomic-anxiety (VSS-AA) subscales. Significant difference between the median scores for patient and healthy groups was reported in discriminate validity (P <0.001). Convergent validity revealed high correlation between both BAI and DHI with VSS-P. There was a high test-retest reliability; with intraclass correlation coefficient of 0.89, 0.86, and 0.91 for VSS-AA, VER, and VSS-P, respectively. The internal consistency was good with Cronbach's alpha 0.90 for VER subscale, 0.86 for VSS-AA subscale, and 0.92 for the overall VSS-P. Conclusion: The Persian version of the VSS could be used clinically as a valid and reliable tool. Thus, it is a key instrument to focus on the symptoms associated with dizziness. PMID:28616045
Development of the Persian version of the Vertigo Symptom Scale: Validity and reliability.
Kamalvand, Atefeh; Ghahraman, Mansoureh Adel; Jalaie, Shohreh
2017-01-01
Vertigo Symptom Scale (VSS) is a proper instrument for assessing the patient status, clarifying the symptoms, and examining the relative impact of the vertigo and anxiety on reported handicap. Our aim is the translation and cross-cultural adaptation of the VSS into Persian language (VSS-P) and investigating its validity and reliability in patients with peripheral vestibular disorders. VSS was translated into Persian. Cross-cultural adaptation was carried out on 101 patients with peripheral vestibular disorders and 34 participants with no history of vertigo. They completed the Persian versions of VSS, dizziness handicap inventory (DHI), and Beck anxiety inventory (BAI). Internal, discriminant, and convergent validities, internal consistency, and test-retest reliability were determined. The VSS-P showed good face validity. Internal validity was confirmed and demonstrated the presence of two vertigo (VSS-VER) and autonomic-anxiety (VSS-AA) subscales. Significant difference between the median scores for patient and healthy groups was reported in discriminate validity ( P <0.001). Convergent validity revealed high correlation between both BAI and DHI with VSS-P. There was a high test-retest reliability; with intraclass correlation coefficient of 0.89, 0.86, and 0.91 for VSS-AA, VER, and VSS-P, respectively. The internal consistency was good with Cronbach's alpha 0.90 for VER subscale, 0.86 for VSS-AA subscale, and 0.92 for the overall VSS-P. The Persian version of the VSS could be used clinically as a valid and reliable tool. Thus, it is a key instrument to focus on the symptoms associated with dizziness.
The city of hope-quality of life-ostomy questionnaire: persian translation and validation.
Anaraki, F; Vafaie, M; Behboo, R; Esmaeilpour, S; Maghsoodi, N; Safaee, A; Grant, M
2014-07-01
Since there is no disease-specific instrument for measuring quality-of-life (QOL) in Ostomy patients in Persian language. This study was designed to translate and evaluate the validity and reliability of City of Hope-quality of life-Ostomy questionnaire (COH-QOL-Ostomy questionnaire). This study was designed as cross-sectional study. Reliability of the subscales and the summary scores were demonstrated by intra-class correlation coefficients. Pearson's correlations of an item with its own scale and other scales were calculated to evaluated convergent and discriminant validity. Clinical validity was also evaluated by known-group comparisons. Cronbach's alpha coefficient for all subscales was about 0.70 or higher. Results of interscale correlation were satisfactory and each subscale only measured a single and specified trait. All subscales met the standards of convergent and discriminant validity. Known group comparison analysis showed significant differences in social and spiritual well-being. The findings confirmed the reliability and validity of Persian version of COH-QOL-Ostomy questionnaire. The instrument was also well received by the Iranian patients. It can be considered as a valuable instrument to assess the different aspects of health related quality-of-life in Ostomy patients and used in clinical research in the future.
The Spanish version of the Alberta Infant Motor Scale: Validity and reliability analysis.
Morales-Monforte, Erica; Bagur-Calafat, Caridad; Suc-Lerin, Neus; Fornaguera-Martí, Montserrat; Cazorla-Sánchez, Engracia; Girabent-Farrés, Montserrat
2017-02-01
Validity and reliability of the cross-cultural adaptive translation of the Alberta Infant Motor Scale (AIMS), to monitor gross motor development in infants from 0 to 18 months of age, were evaluated. A cross-cultural translation was used to generate a Spanish version of the AIMS. Fifty infants at risk or with diagnosis of motor delay, 0-18 months of age, participated in this study. Two independent physical therapists scored infants on the AIMS. Concurrent validity was tested using the AIMS and the Bayley Scales of Infant and Toddler Development - III (Bayley - III). Reliability and the internal consistency were high (ICCs ranged from 0.94 to 1.00 and KR-20 ranged from 0.90 to 0.98, respectively). AIMS and Bayley - III scores correlated strongly (r = 0.97). The Spanish version of the AIMS presented excellent validity and reliability. Further studies are suggested in order to assess the AIMS in preterm babies.
Gunaydin, Gurkan; Citaker, Seyit; Meray, Jale; Cobanoglu, Gamze; Gunaydin, Ozge Ece; Hazar Kanik, Zeynep
2016-11-01
Validation of a self-report questionnaire. The purpose of this study was to investigate adaptation, validity, and reliability of the Turkish version of the Bournemouth Questionnaire. Low back pain is one of the most frequent disorders leading to activity limitation. This pain affects most of people in their lives. The most important point to evaluate patient's functional abilities and to decide a successful therapy procedure is to manage the assessment questionnaires precisely. One hundred ten patients with chronic low back pain were included in present study. To assess reliability, test-retest and internal consistency analyses were applied. The results of test-retest analysis were assessed by using Intraclass Correlation Coefficient method (95% confidence interval). For internal consistency, Cronbach alpha value was calculated. Validity of the questionnaire was assessed in terms of construct validity. For construct validity, factor analysis and convergent validity were tested. For convergent validity, total points of the Bournemouth Questionnaire were assessed with the total points of Quebec Back Pain Disability Scale and Roland Morris Disability Questionnaire by using Pearson correlation coefficient analysis. Cronbach alpha value was found 0.914, showing that this questionnaire has high internal consistency. The results of test-retest analysis were varying between 0.851 and 0.927, which shows that test-retest results are highly correlated. Factor analysis test indicated that this questionnaire had one factor. Pearson correlation coefficient of the Bournemouth Questionnaire with Roland Morris Disability Questionnaire was calculated 0.703 and it was found with Quebec Back Pain Disability Scale is 0.659. These results showed that the Bournemouth Questionnaire is very good correlated with Roland Morris Disability Questionnaire and Quebec Back Pain Disability Scale. The Turkish version of the Bournemouth Questionnaire is valid and reliable. 3.
Mbada, Chidozie Emmanuel; Idowu, Opeyemi Ayodiipo; Ogunjimi, Olawale Richard; Ayanniyi, Olusola; Orimolade, Elkanah Ayodele; Oladiran, Ajibola Babatunde; Johnson, Olubusola Esther; Akinsulore, Adesanmi; Oni, Temitope Olawale
2017-04-01
A translation, cross-cultural adaptation, and psychometric analysis. The aim of this study was to translate, cross-culturally adapt, and validate the Yoruba version of the RMDQ. The Roland-Morris Disability Questionnaire (RMDQ) is a valid outcome tool for low back pain (LBP) in clinical and research settings. There seems to be no valid and reliable version of the RMDQ in the Nigerian languages. Following the Guillemin criteria, the English version of the RMDQ was forward and back translated. Two Yoruba translated versions of the RMDQ were assessed for clarity, common language usage, and conceptual equivalence. Consequently, a harmonized Yoruba version was produced and was pilot-tested among 20 patients with nonspecific long-term LBP (NSLBP) for cognitive debriefing. The final version of the Yoruba RMDQ was tested for its construct validity and re-retest reliability among 120 and 87 patients with NSLBP, respectively. Pearson product moment correlation coefficient (r) of 0.82 was obtained for reliability of the Yoruba version of the RMDQ. The test-retest reliability of the Yoruba RMDQ yielded Cronbach alpha 0.932, while the intraclass correlation (ICC) ranged between 0.896 and 0.956. The analysis of the global scores of both the English and Yoruba versions of the RMDQ yielded ICC value of between 0.995 (95% confidence interval 0.996-0.997), with the item-by-item Kappa agreement ranging between 0.824 and 1.000. The external validity of RMDQ using Quadruple Visual Analogue Scale was r = -0.596 (P = 0.001). The Yoruba version of the RMDQ had no floor/ceiling effects, as no patient achieved either of the maximum or the minimum possible scores. The Yoruba version of the RMDQ has excellent reliability and validity and may be an appropriate outcome tool for clinical and research purposes among Yoruba-speaking patients with LBP. 3.
Sisic, Nedim; Jelicic, Mario; Pehar, Miran; Spasic, Miodrag; Sekulic, Damir
2016-01-01
In basketball, anthropometric status is an important factor when identifying and selecting talents, while agility is one of the most vital motor performances. The aim of this investigation was to evaluate the influence of anthropometric variables and power capacities on different preplanned agility performances. The participants were 92 high-level, junior-age basketball players (16-17 years of age; 187.6±8.72 cm in body height, 78.40±12.26 kg in body mass), randomly divided into a validation and cross-validation subsample. The predictors set consisted of 16 anthropometric variables, three tests of power-capacities (Sargent-jump, broad-jump and medicine-ball-throw) as predictors. The criteria were three tests of agility: a T-Shape-Test; a Zig-Zag-Test, and a test of running with a 180-degree turn (T180). Forward stepwise multiple regressions were calculated for validation subsamples and then cross-validated. Cross validation included correlations between observed and predicted scores, dependent samples t-test between predicted and observed scores; and Bland Altman graphics. Analysis of the variance identified centres being advanced in most of the anthropometric indices, and medicine-ball-throw (all at P<0.05); with no significant between-position-differences for other studied motor performances. Multiple regression models originally calculated for the validation subsample were then cross-validated, and confirmed for Zig-zag-Test (R of 0.71 and 0.72 for the validation and cross-validation subsample, respectively). Anthropometrics were not strongly related to agility performance, but leg length is found to be negatively associated with performance in basketball-specific agility. Power capacities are confirmed to be an important factor in agility. The results highlighted the importance of sport-specific tests when studying pre-planned agility performance in basketball. The improvement in power capacities will probably result in an improvement in agility in basketball athletes, while anthropometric indices should be used in order to identify those athletes who can achieve superior agility performance.
Kim, Ho-Joong; Ruscheweyh, Ruth; Yeo, Ji-Hyun; Cho, Hyeon-Guk; Yi, Je-Min; Chang, Bong-Soon; Lee, Choon-Ki; Yeom, Jin S
2014-11-01
The purpose of this study was to translate pain sensitivity questionnaires (PSQ) into the Korean language, perform a cross-cultural adaption of the PSQ, and validate the Korean version of PSQ in patients with degenerative spinal disease. The PSQ was translated forward and backward, cross-culturally adapted by 2 independent translators, and approved by an expert committee. The final Korean version of the PSQ was tested on 72 patients with degenerative spinal disease. Test-retest reliability was evaluated for 60 patients (83%) who completed the second assessment in an interval of 4 weeks. The mean PSQ-minor, PSQ-moderate, and PSQ-total (standard deviation [SD]) were 5.40 (2.02), 6.46 (1.98), and 5.93 (1.93), respectively. The PSQ-total, PSQ-minor, and PSQ-moderate of the Korean version showed very good internal consistencies determined by the Cronbach's α of 0.926, 0.869, and 0.877, respectively. For convergent validity, the PSQ scores of the Korean version showed significant correlations with pain catastrophizing scale (PCS) (r = 0.377, P = 0.002; r = 0.365, P = 0.003; r = 0.362, P = 0.003 for PSQ-total, PSQ-minor, and PSQ-moderate of the Korean version, respectively). For test-retest reliability, the intraclass correlation coefficients were 0.782 for PSQ-total, 0.752 for PSQ-minor, and 0.793 for PSQ-moderate. In conclusion, the validated Korean version of PSQ is a transculturally equivalent, reliable, and valid tool to assess individual pain sensitivity. © 2013 World Institute of Pain.
Hadadi, Mohammad; Ebrahimi Takamjani, Ismail; Ebrahim Mosavi, Mohammad; Aminian, Gholamreza; Fardipour, Shima; Abbasi, Faeze
2017-08-01
The purpose of the present study was to translate and to cross-culturally adapt the Cumberland Ankle Instability Tool (CAIT) into Persian language and to evaluate its psychometric properties. The International Quality of Life Assessment process was pursued to translate CAIT into Persian. Two groups of Persian-speaking individuals, 105 participants with a history of ankle sprain and 30 participants with no history of ankle sprain, were asked to fill out Persian version of CAIT (CAIT-P), Foot and Ankle Ability Measure (FAAM), and Visual Analog Scale (VAS). Data obtained from the first administration of CAIT were used to evaluate floor and ceiling effects, internal consistency, dimensionality, and criterion validity. To determine the test-retest reliability, 45 individuals re-filled CAIT 5-7 days after the first session. Cronbach's alpha was over the cutoff point of 0.70 for both ankles and in both groups. The intra-class correlation coefficient was high for right (0.95) and left (0.91) ankles. There was a strong correlation between each item and the total score of the CAIT-P. Although the CAIT-P had strong correlation with VAS, its correlation with both subscales of FAAM was moderate. The CAIT-P has good validity and reliability and it can be used by clinicians and researchers for identification and investigation of functional ankle instability. Implications for Rehabilitation Chronic ankle instability is one of the most common consequences of acute ankle sprain. Cumberland Ankle Instability Tool is an acceptable measure to determine functional ankle instability and its severity. The Persian version of Cumberland Ankle Instability Tool is a valid and reliable tool for clinical and research purpose in Persian-speaking individuals.
Reproducibility and validity of a semi-quantitative FFQ for trace elements.
Lee, Yujin; Park, Kyong
2016-09-01
The aim of this study was to test the reproducibility and validity of a self-administered FFQ for the Trace Element Study of Korean Adults in the Yeungnam area (SELEN). Study subjects were recruited from the SELEN cohort selected from rural and urban areas in Yeungnam, Korea. A semi-quantitative FFQ with 146 items was developed considering the dietary characteristics of cohorts in the study area. In a validation study, seventeen men and forty-eight women aged 38-62 years completed 3-d dietary records (DR) and two FFQ over a 3-month period. The validity was examined with the FFQ and DR, and the reproducibility was estimated using partial correlation coefficients, the Bland-Altman method and cross-classification. There were no significant differences between the mean intakes of selected nutrients as estimated from FFQ1, FFQ2 and DR. The median correlation coefficients for all nutrients were 0·47 and 0·56 in the reproducibility and validity tests, respectively. Bland-Altman's index and cross-classification showed acceptable agreement between FFQ1 and FFQ2 and between FFQ2 and DR. Ultimately, 78 % of the subjects were classified into the same and adjacent quartiles for most nutrients. In addition, the weighted κ value indicated that the two methods agreed fairly. In conclusion, this newly developed FFQ was a suitable dietary assessment method for the SELEN cohort study.
Kim, Jin Goo; Lee, Joong Yub; Seo, Seung Suk; Choi, Choong Hyeok; Lee, Myung Chul
2013-01-01
Purpose To perform a cross-cultural adaptation and to test the measurement properties of the Korean version of International Knee Documentation Committee (K-IKDC) Subjective Knee Form. Materials and Methods According to the guidelines for cross-cultural adaptation, translation and backward translation of the English version of the IKDC Subjective Knee Form were performed. After translation into the Korean version, 150 patients who had knee-related problems were asked to complete the K-IKDC, Lysholm score, and Short Form-36 (SF-36). Of these patients, 126 were retested 2 weeks later to evaluate test-retest reliability, and 104 were recruited 3 months later to evaluate responsiveness. Construct validity was analyzed by investigating the correlation with Lysholm score and SF-36; content validity was also evaluated. Standardized mean response was calculated for evaluating responsiveness. Results The test-retest reliability proved excellent with a high value for the intraclass correlation coefficient (r=0.94). The internal consistency was strong (Cronbach's α=0.91). Good content validity with absence of floor not ceiling effects and good convergent and divergent validity were observed. Moderate responsiveness was shown (standardized mean response=0.689). Conclusions The K-IKDC demonstrated good measurement properties. We suggest that this instrument is an excellent evaluation instrument that can be used for Korean patients with knee-related injuries. PMID:24032098
Cross-cultural adaptation and validation of the Turkish version of Oxford hip score.
Tuğay, Baki Umut; Tuğay, Nazan; Güney, Hande; Hazar, Zeynep; Yüksel, İnci; Atilla, Bülent
2015-06-01
The purpose of this study was to translate the Oxford hip score (OHS) into Turkish and to evaluate the psychometric properties by testing the internal consistency, reproducibility, construct validity, and responsiveness in patients with hip osteoarthritis (OA). Oxford hip score was translated and culturally adapted according to the guidelines in the literature. Seventy patients (mean age 61.45 ± 9.29 years) with hip osteoarthritis participated in the study. Patients completed the Turkish Oxford hip score (OHS-TR), the Short-Form 36 (SF-36), and Western Ontario and McMaster Universities Index (WOMAC). Internal consistency was tested using Cronbach's α coefficient. Patients completed OHS-TR questionnaire twice in 7 days for determining the reproducibility. Correlation between the total results of both tests was determined by the Pearson correlation coefficient and intraclass correlation coefficient (ICC). Validity was assessed by calculating the Pearson correlation coefficient between the OHS-TR and WOMAC and SF-36 scores. Floor and ceiling effects were analyzed. The internal consistency was high (Cronbach's α 0.93). The construct validity showed a significant correlation between the OHS-TR and WOMAC and related SF-36 domains (p < 0.001). The ICC's ranged between 0.80 and 0.99. There was no floor or ceiling effect in total OHS-TR score. The OHS-TR questionnaire is valid, reliable, and responsive for the Turkish-speaking patients with hip OA.
Medina, Maria Del Mar; Carrillo, Alvaro; Polo, Ruben; Fernandez, Borja; Alonso, Daniel; Vaca, Miguel; Cordero, Adela; Perez, Cecilia; Muriel, Alfonso; Cobeta, Ignacio
2017-04-01
Objective To perform translation, cross-cultural adaptation, and validation of the Penn Acoustic Neuroma Quality-of-Life Scale (PANQOL) to the Spanish language. Study Design Prospective study. Setting Tertiary neurotologic referral center. Subjects and Methods PANQOL was translated and translated back, and a pretest trial was performed. The study included 27 individuals diagnosed with vestibular schwannoma. Inclusion criteria were adults with untreated vestibular schwannoma, diagnosed in the past 12 months. Feasibility, internal consistency, test-retest reliability, construct validity, and ceiling and floor effects were assessed for the present study. Results The mean overall score of the PANQOL was 69.21 (0-100 scale, lowest to highest quality of life). Cronbach's α was 0.87. Intraclass correlation coefficient was performed for each item, with an overall score of 0.92. The κ coefficient scores were between moderate and almost perfect in more than 92% of patients. Anxiety and energy domains of the PANQOL were correlated with both physical and mental components of the SF-12. Hearing, balance, and pain domains were correlated with the SF-12 physical component. Facial and general domains were not significantly correlated with any component of the SF-12. Furthermore, the overall score of the PANQOL was correlated with the physical component of the SF-12. Conclusion Feasibility, internal consistency, reliability, and construct validity outcomes in the current study support the validity of the Spanish version of the PANQOL.
Bittante, G; Ferragina, A; Cipolat-Gotet, C; Cecchinato, A
2014-10-01
Cheese yield is an important technological trait in the dairy industry. The aim of this study was to infer the genetic parameters of some cheese yield-related traits predicted using Fourier-transform infrared (FTIR) spectral analysis and compare the results with those obtained using an individual model cheese-producing procedure. A total of 1,264 model cheeses were produced using 1,500-mL milk samples collected from individual Brown Swiss cows, and individual measurements were taken for 10 traits: 3 cheese yield traits (fresh curd, curd total solids, and curd water as a percent of the weight of the processed milk), 4 milk nutrient recovery traits (fat, protein, total solids, and energy of the curd as a percent of the same nutrient in the processed milk), and 3 daily cheese production traits per cow (fresh curd, total solids, and water weight of the curd). Each unprocessed milk sample was analyzed using a MilkoScan FT6000 (Foss, Hillerød, Denmark) over the spectral range, from 5,000 to 900 wavenumber × cm(-1). The FTIR spectrum-based prediction models for the previously mentioned traits were developed using modified partial least-square regression. Cross-validation of the whole data set yielded coefficients of determination between the predicted and measured values in cross-validation of 0.65 to 0.95 for all traits, except for the recovery of fat (0.41). A 3-fold external validation was also used, in which the available data were partitioned into 2 subsets: a training set (one-third of the herds) and a testing set (two-thirds). The training set was used to develop calibration equations, whereas the testing subsets were used for external validation of the calibration equations and to estimate the heritabilities and genetic correlations of the measured and FTIR-predicted phenotypes. The coefficients of determination between the predicted and measured values in cross-validation results obtained from the training sets were very similar to those obtained from the whole data set, but the coefficient of determination of validation values for the external validation sets were much lower for all traits (0.30 to 0.73), and particularly for fat recovery (0.05 to 0.18), for the training sets compared with the full data set. For each testing subset, the (co)variance components for the measured and FTIR-predicted phenotypes were estimated using bivariate Bayesian analyses and linear models. The intraherd heritabilities for the predicted traits obtained from our internal cross-validation using the whole data set ranged from 0.085 for daily yield of curd solids to 0.576 for protein recovery, and were similar to those obtained from the measured traits (0.079 to 0.586, respectively). The heritabilities estimated from the testing data set used for external validation were more variable but similar (on average) to the corresponding values obtained from the whole data set. Moreover, the genetic correlations between the predicted and measured traits were high in general (0.791 to 0.996), and they were always higher than the corresponding phenotypic correlations (0.383 to 0.995), especially for the external validation subset. In conclusion, we herein report that application of the cross-validation technique to the whole data set tended to overestimate the predictive ability of FTIR spectra, give more precise phenotypic predictions than the calibrations obtained using smaller data sets, and yield genetic correlations similar to those obtained from the measured traits. Collectively, our findings indicate that FTIR predictions have the potential to be used as indicator traits for the rapid and inexpensive selection of dairy populations for improvement of cheese yield, milk nutrient recovery in curd, and daily cheese production per cow. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
PCA as a practical indicator of OPLS-DA model reliability.
Worley, Bradley; Powers, Robert
Principal Component Analysis (PCA) and Orthogonal Projections to Latent Structures Discriminant Analysis (OPLS-DA) are powerful statistical modeling tools that provide insights into separations between experimental groups based on high-dimensional spectral measurements from NMR, MS or other analytical instrumentation. However, when used without validation, these tools may lead investigators to statistically unreliable conclusions. This danger is especially real for Partial Least Squares (PLS) and OPLS, which aggressively force separations between experimental groups. As a result, OPLS-DA is often used as an alternative method when PCA fails to expose group separation, but this practice is highly dangerous. Without rigorous validation, OPLS-DA can easily yield statistically unreliable group separation. A Monte Carlo analysis of PCA group separations and OPLS-DA cross-validation metrics was performed on NMR datasets with statistically significant separations in scores-space. A linearly increasing amount of Gaussian noise was added to each data matrix followed by the construction and validation of PCA and OPLS-DA models. With increasing added noise, the PCA scores-space distance between groups rapidly decreased and the OPLS-DA cross-validation statistics simultaneously deteriorated. A decrease in correlation between the estimated loadings (added noise) and the true (original) loadings was also observed. While the validity of the OPLS-DA model diminished with increasing added noise, the group separation in scores-space remained basically unaffected. Supported by the results of Monte Carlo analyses of PCA group separations and OPLS-DA cross-validation metrics, we provide practical guidelines and cross-validatory recommendations for reliable inference from PCA and OPLS-DA models.
Scale for positive aspects of caregiving experience: development, reliability, and factor structure.
Kate, N; Grover, S; Kulhara, P; Nehra, R
2012-06-01
OBJECTIVE. To develop an instrument (Scale for Positive Aspects of Caregiving Experience [SPACE]) that evaluates positive caregiving experience and assess its psychometric properties. METHODS. Available scales which assess some aspects of positive caregiving experience were reviewed and a 50-item questionnaire with a 5-point rating was constructed. In all, 203 primary caregivers of patients with severe mental disorders were asked to complete the questionnaire. Internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity were evaluated. Principal component factor analysis was run to assess the factorial validity of the scale. RESULTS. The scale developed as part of the study was found to have good internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity. Principal component factor analysis yielded a 4-factor structure, which also had good test-retest reliability and cross-language reliability. There was a strong correlation between the 4 factors obtained. CONCLUSION. The SPACE developed as part of this study has good psychometric properties.
Atmospheric convective velocities and the Fourier phase spectrum
NASA Technical Reports Server (NTRS)
Cliff, W. C.
1974-01-01
The relationship between convective velocity and the Fourier phase spectrum of the cross correlation is developed. By examining the convective velocity as a function of frequency, one may determine if Taylor's conversion from time statistics to space statistics is valid. It is felt that the high shear regions of the atmospheric boundary layer need to be explored to determine the validity of the use of Taylor's hypothesis for this region.
Bae, Sang-Cheol; Lee, Ji-Hyun
2004-05-01
Our aim was to translate and cross-culturally adapt the fibromyalgia impact questionnaire into Korean (KFIQ), and then evaluate its reliability and validity. The FIQ was translated into Korean by three translators and then independently translated back into English by three different translators. A total of 62 women patients with fibromyalgia (FM) were studied for the psychometric properties of the KFIQ. The mean age of the patients was 47.1 (25-73) years, and all were female. The mean KFIQ score was 48.3 (17-91), and the mean Korean health assessment questionnaire (KHAQ) score was 0.4 (0-1.7). The test-retest reliability of the KFIQ yielded an intraclass correlation coefficient of 0.85 (0.53-0.96). For the construct validity, the Spearman rank correlations of KFIQ with patient global assessments using visual analog scale (pain, 0.58; morning stiffness, 0.45; fatigue, 0.48; depression, 0.43; anxiety, 0.56; global well-being, 0.46; disease severity, 0.49; impact on life, 0.51), KHAQ (0.44), and tender points (0.60) were high and statistically significant. The KFIQ might be a reliable and valid instrument for measuring health status and physical functioning in Korean women patients with FM, but needs further study.
Health Service Quality Scale: Brazilian Portuguese translation, reliability and validity.
Rocha, Luiz Roberto Martins; Veiga, Daniela Francescato; e Oliveira, Paulo Rocha; Song, Elaine Horibe; Ferreira, Lydia Masako
2013-01-17
The Health Service Quality Scale is a multidimensional hierarchical scale that is based on interdisciplinary approach. This instrument was specifically created for measuring health service quality based on marketing and health care concepts. The aim of this study was to translate and culturally adapt the Health Service Quality Scale into Brazilian Portuguese and to assess the validity and reliability of the Brazilian Portuguese version of the instrument. We conducted a cross-sectional, observational study, with public health system patients in a Brazilian university hospital. Validity was assessed using Pearson's correlation coefficient to measure the strength of the association between the Brazilian Portuguese version of the instrument and the SERVQUAL scale. Internal consistency was evaluated using Cronbach's alpha coefficient; the intraclass (ICC) and Pearson's correlation coefficients were used for test-retest reliability. One hundred and sixteen consecutive postoperative patients completed the questionnaire. Pearson's correlation coefficient for validity was 0.20. Cronbach's alpha for the first and second administrations of the final version of the instrument were 0.982 and 0.986, respectively. For test-retest reliability, Pearson's correlation coefficient was 0.89 and ICC was 0.90. The culturally adapted, Brazilian Portuguese version of the Health Service Quality Scale is a valid and reliable instrument to measure health service quality.
Validity and cross-cultural adaptation of the persian version of the oxford elbow score.
Ebrahimzadeh, Mohammad H; Kachooei, Amir Reza; Vahedi, Ehsan; Moradi, Ali; Mashayekhi, Zeinab; Hallaj-Moghaddam, Mohammad; Azami, Mehran; Birjandinejad, Ali
2014-01-01
Oxford Elbow Score (OES) is a patient-reported questionnaire used to assess outcomes after elbow surgery. The aim of this study was to validate and adapt the OES into Persian language. After forward-backward translation of the OES into Persian, a total number of 92 patients after elbow surgeries completed the Persian OES along with the Persian DASH and SF-36. To assess test-retest reliability, 31 randomly selected patients (34%) completed the Persian OES again after three days while abstaining from all forms of therapeutic regimens. Reliability of the Persian OES was assessed by measuring intraclass correlation coefficient (ICC) for test-retest reliability and Cronbach's alpha for internal consistency. Spearman's correlation coefficient was used to test the construct validity. Cronbach's alpha coefficient was 0.92 showing excellent reliability. Cronbach's alpha for function, pain, and social-psychological subscales was 0.95, 0.86, and 0.85, respectively. Intraclass correlation coefficient (ICC) was 0.85 for the overall questionnaire and 0.90, 0.76, and 0.75 for function, pain, and social-psychological subscales, respectively. Construct validity was confirmed as the Spearman correlation between OES and DASH was 0.80. Persian OES is a valid and reliable patient-reported outcome measure to assess postsurgical elbow status in Persian speaking population.
Muscle synergies during bench press are reliable across days.
Kristiansen, Mathias; Samani, Afshin; Madeleine, Pascal; Hansen, Ernst Albin
2016-10-01
Muscle synergies have been investigated during different types of human movement using nonnegative matrix factorization. However, there are not any reports available on the reliability of the method. To evaluate between-day reliability, 21 subjects performed bench press, in two test sessions separated by approximately 7days. The movement consisted of 3 sets of 8 repetitions at 60% of the three repetition maximum in bench press. Muscle synergies were extracted from electromyography data of 13 muscles, using nonnegative matrix factorization. To evaluate between-day reliability, we performed a cross-correlation analysis and a cross-validation analysis, in which the synergy components extracted in the first test session were recomputed, using the fixed synergy components from the second test session. Two muscle synergies accounted for >90% of the total variance, and reflected the concentric and eccentric phase, respectively. The cross-correlation values were strong to very strong (r-values between 0.58 and 0.89), while the cross-validation values ranged from substantial to almost perfect (ICC3, 1 values between 0.70 and 0.95). The present findings revealed that the same general structure of the muscle synergies was present across days and the extraction of muscle synergies is thus deemed reliable. Copyright © 2016 Elsevier Ltd. All rights reserved.
Remelhe, Mafalda; Teixeira, Pedro M; Lopes, Irene; Silva, Luís; Correia de Sousa, Jaime
2017-01-12
Enabling patients with asthma to obtain the knowledge, confidence and skills they need in order to assume a major role in the management of their disease is cost effective. It should be an integral part of any plan for long-term control of asthma. The modified Patient Enablement Instrument (mPEI) is an easily administered questionnaire that was adapted in the United Kingdom to measure patient enablement in asthma, but its applicability in Portugal is not known. Validity and reliability of questionnaires should be tested before use in settings different from those of the original version. The purpose of this study was to test the applicability of the mPEI to Portuguese asthma patients after translation and cross-cultural adaptation, and to verify the structural validity, internal consistency and reproducibility of the instrument. The mPEI was translated to Portuguese and back translated to English. Its content validity was assessed by a debriefing interview with 10 asthma patients. The translated instrument was then administered to a random sample of 142 patients with persistent asthma. Structural validity and internal consistency were assessed. For reproducibility analysis, 86 patients completed the instrument again 7 days later. Item-scale correlations and exploratory factor analysis were used to assess structural validity. Cronbach's alpha was used to test internal consistency, and the intra-class correlation coefficient was used for the analysis of reproducibility. All items of the Portuguese version of the mPEI were found to be equivalent to the original English version. There were strong item-scale correlations that confirmed construct validity, with a one component structure and good internal consistency (Cronbach's alpha >0.8) as well as high test-retest reliability (ICC=0.85). The mPEI showed sound psychometric properties for the evaluation of enablement in patients with asthma making it a reliable instrument for use in research and clinical practice in Portugal. Further studies are needed to confirm its responsiveness.
Simons, M; Kee, E Gee; Kimble, R; Tyack, Z
2017-08-01
The aim of this study was to investigate the reproducibility and validity of measuring scar height in children using ultrasound and 3D camera. Using a cross-sectional design, children with discrete burn scars were included. Reproducibility was tested using Intraclass Correlation Coefficient (ICC) for reliability, and percentage agreement within 1mm between test and re-test, standard error of measurement (SEM), smallest detectable change (SDC) and Bland Altman limits of agreement for agreement. Concurrent validity was tested using Spearman's rho for support of pre-specified hypotheses. Forty-nine participants (55 scars) were included. For ultrasound, test-retest and inter-rater reproducibility of scar thickness was acceptable for scarred skin (ICC=0.95, SDC=0.06cm and ICC=0.82, SDC=0.14cm). The ultrasound picked up changes of <1mm. Inter-rater reproducibility of maximal scar height using the 3D camera was acceptable (ICC=0.73, SDC=0.55cm). Construct validity of the ultrasound was supported with a strong correlation between the measure of scar thickness and observer ratings of thickness using the POSAS (ρ=0.61). Construct validity of the 3D camera was also supported with a moderate correlation (ρ=0.37) with the same measure using maximal scar height. The ultrasound is capable of detecting smaller changes or differences in scar thickness than the 3D camera, in children with burn scars. However agreement as part of reproducibility was lower than expected between raters for the ultrasound. Improving the accuracy of scar relocation may go some way to address agreement. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Flosadottir, Vala; Roos, Ewa M.; Ageberg, Eva
2017-01-01
Background: The Activity Rating Scale (ARS) for disorders of the knee evaluates the level of activity by the frequency of participation in 4 separate activities with high demands on knee function, with a score ranging from 0 (none) to 16 (pivoting activities 4 times/wk). Purpose: To translate and cross-culturally adapt the ARS into Swedish and to assess measurement properties of the Swedish version of the ARS. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: The COSMIN guidelines were followed. Participants (N = 100 [55 women]; mean age, 27 years) who were undergoing rehabilitation for a knee injury completed the ARS twice for test-retest reliability. The Knee injury and Osteoarthritis Outcome Score (KOOS), Tegner Activity Scale (TAS), and modernized Saltin-Grimby Physical Activity Level Scale (SGPALS) were administered at baseline to validate the ARS. Construct validity and responsiveness of the ARS were evaluated by testing predefined hypotheses regarding correlations between the ARS, KOOS, TAS, and SGPALS. The Cronbach alpha, intraclass correlation coefficients, absolute reliability, standard error of measurement, smallest detectable change, and Spearman rank-order correlation coefficients were calculated. Results: The ARS showed good internal consistency (α ≈ 0.96), good test-retest reliability (intraclass correlation coefficient >0.9), and no systematic bias between measurements. The standard error of measurement was less than 2 points, and the smallest detectable change was less than 1 point at the group level and less than 5 points at the individual level. More than 75% of the hypotheses were confirmed, indicating good construct validity and good responsiveness of the ARS. Conclusion: The Swedish version of the ARS is valid, reliable, and responsive for evaluating the level of activity based on the frequency of participation in high-demand knee sports activities in young adults with a knee injury. PMID:28979920
Wang, W; Liu, L; Chang, X; Jia, Z Y; Zhao, J Z; Xu, W D
2016-10-19
The Lysholm Knee Score (LKS) is widely used and is one of the most effective questionnaires employed to assess knee injuries. Although LKS has been translated into multiple languages, there is no Chinese version even though China has the largest population of patients with knee-joint injuries. The objective of our study was to develop the Chinese version of LKS (C-LKS) and assess its reliability, validity and responsiveness in Chinese patients with anterior cruciate ligament (ACL) injuries. Study participants were mainly recruited among patients with ACL injuries scheduled for arthroscopic ACL reconstruction at our hospital. First, we developed the C-LKS in a five-step translation and cross-cultural adaptation procedure. Next, we calculated the Cronbach's alpha, intraclass correlation coefficient (ICC), Pearson's correlation coefficient (r), effect size (ES), and standardized response mean (SRM) to evaluate the reliability, validity, and responsiveness of C-LKS respectively. Overall, 126 patients with ACL injuries successfully completed the questionnaires. Acceptable internal consistency (Cronbach's alpha = 0.726) as well as excellent test-retest reliability (ICC = 0.935) was found for C-LKS. Good or moderate correlation (r = 0.514-0.837) was determined among C-LKS and International Knee Documentation Committee Subjective Knee Form (IKDC), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), physical subscales of SF-36; C-LKS also had fair or moderate correlation (r = 0.207-0.462) with the other subscales of SF-36, which adequately illustrated that good validity was included in C-LKS. In addition, good responsiveness was also observed in C-LKS (ES = 1.36,SRM = 1.26). We have shown that our developed C-LKS questionnaire is reliable, valid and responsible for the evaluation of Chinese-speaking patients with ACL injuries and it would be an effective instrument.
Mills, Tamara L; Holm, Margo B; Schmeler, Mark
2007-01-01
The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p < .001, and the content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p < .001, and captured 98.5% of consumers' seating-mobility goals. The cross-validation study identified new categories of seating-mobility goals for inclusion in FEW Version 2.0, and the content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.
Hanbury Brown and Twiss noise correlations in a topological superconductor beam splitter
NASA Astrophysics Data System (ADS)
Jonckheere, T.; Rech, J.; Zazunov, A.; Egger, R.; Martin, T.
2017-02-01
We study Hanbury Brown and Twiss current cross-correlations in a three-terminal junction where a central topological superconductor (TS) nanowire, bearing Majorana bound states at its ends, is connected to two normal leads. Relying on a nonperturbative Green function formalism, our calculations allow us to provide analytical expressions for the currents and their correlations at subgap voltages, while also giving exact numerical results valid for arbitrary external bias. We show that when the normal leads are biased at voltages V1 and V2 smaller than the gap, the sign of the current cross-correlations is given by -sgn(V1V2) . In particular, this leads to positive cross-correlations for opposite voltages, a behavior in stark contrast with the one of a standard superconductor, which provides direct evidence of the presence of the Majorana zero mode at the edge of the TS. We further extend our results, varying the length of the TS (leading to an overlap of the Majorana bound states) as well as its chemical potential (driving it away from half-filling), generalizing the boundary TS Green function to those cases. In the case of opposite bias voltages, sgn(V1V2)=-1 , driving the TS wire through the topological transition leads to a sign change of the current cross-correlations, providing yet another signature of the physics of the Majorana bound state.
Middleton, James W; Tran, Yvonne; Lo, Charles; Craig, Ashley
2016-12-01
To improve the clinical utility of the Moorong Self-Efficacy Scale (MSES) by reexamining its factor structure and comparing its performance against a measure of general self-efficacy in persons with spinal cord injury (SCI). Cross-sectional survey design. Community. Adults with SCI (N=161; 118 men and 43 women) recruited from Australia (n=82) and the United States (n=79), including 86 with paraplegia and 75 with tetraplegia. None. Confirmatory factor analysis deriving fit indices on reported 1-, 2-, and 3-factor structures for the MSES. Exploratory factor analysis of MSES using principal component analysis with promax oblique rotation and structure validation, with correlations and multiple regression using cross-sectional data from the Sherer General Self-Efficacy Scale and Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36). The MSES was confirmed to have a 3-factor structure, explaining 61% of variance. Two of the factors, labeled social function self-efficacy and personal function self-efficacy, were SCI condition-specific, whereas the other factor (accounting for 9.7% of variance) represented general self-efficacy, correlating most strongly with the Sherer General Self-Efficacy Scale. Correlations and multiple regression analyses between MSES factors, Sherer General Self-Efficacy Scale total score, SF-36 Physical and Mental Component Summary scores, and SF-36 domain scores support validity of this MSES factor structure. No significant cross-cultural differences existed between Australia and the United States in total MSES or factor scores. The findings support a 3-factor structure encompassing general and SCI domain-specific self-efficacy beliefs and better position the MSES to assist SCI rehabilitation assessment, planning, and research. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Cross-correlation Doppler global velocimetry (CC-DGV)
NASA Astrophysics Data System (ADS)
Cadel, Daniel R.; Lowe, K. Todd
2015-08-01
A flow velocimetry method, cross-correlation Doppler global velocimetry (CC-DGV), is presented as a robust, simplified, and high dynamic range implementation of the Doppler global/planar Doppler velocimetry technique. A sweep of several gigahertz of the vapor absorption spectrum is used for each velocity sample, with signals acquired from both Doppler-shifted scattered light within the flow and a non-Doppler shifted reference beam. Cross-correlation of these signals yields the Doppler shift between them, averaged over the duration of the scan. With presently available equipment, velocities from 0 ms-1 to over 3000 ms-1 can notionally be measured simultaneously, making the technique ideal for high speed flows. The processing routine is shown to be robust against large changes in the vapor pressure of the iodine cell, benefiting performance of the system in facilities where ambient conditions cannot be easily regulated. Validation of the system was performed with measurements of a model wind turbine blade boundary layer made in a 1.83 m by 1.83 m subsonic wind tunnel for which laser Doppler velocimetry (LDV) measurements were acquired alongside the CC-DGV results. CC-DGV uncertainties of ±1.30 ms-1, ±0.64 ms-1, and ±1.11 ms-1 were determined for the orthogonal stream-wise, transverse-horizontal, and transverse-vertical velocity components, and root-mean-square deviations of 2.77 ms-1 and 1.34 ms-1 from the LDV validation results were observed for Reynolds numbers of 1.5 million and 2 million, respectively. Volumetric mean velocity measurements are also presented for a supersonic jet, with velocity uncertainties of ±4.48 ms-1, ±16.93 ms-1, and ±0.50 ms-1 for the orthogonal components, and self-validation done by collapsing the data with a physical scaling.
Zhou, Hongzhen; Zhu, Yafang; Zhang, Xiaomei
2017-01-01
This study aimed to validate the Chinese version of the Functional Oral Intake Scale (FOIS) score in acute stroke patients with dysphagia. A sample of 128 consecutive patients with acute stroke, admitted to Department of Neurology from April to October in 2016, completed the FOIS. The interrater reliability, criterion validity, discriminant validity, cross validation, and the sensitivity of FOIS scale were evaluated. Results showed that rater agreements were excellent for FOIS (Kw = 0.881, p < 0.001). A highly negative correlation between FOIS and WST (water swallow test) was detected (r = -0.937, p < 0.001). There was significant difference for FOIS level of patients with different evaluation outcomes (χ2 = 126.551, p < 0.001). The FOIS evaluation results were significantly correlated with two physiological measures of swallowing. The Chinese version of the FOIS score is a reliable scale for evaluating the level of oral feeding function in patients with acute stroke.
Denova-Gutiérrez, Edgar; Ramírez-Silva, Ivonne; Rodríguez-Ramírez, Sonia; Jiménez-Aguilar, Alejandra; Shamah-Levy, Teresa; Rivera-Dommarco, Juan A
2016-01-01
To assess the validity of a 140-item semiquantitative food frequency questionnaire (SFFQ), in Mexican adolescents and adults. Dietary intakes using a SFFQ and two 24-hour dietary recalls (24DRs), in nonconsecutive days during the same week were measured from 178 adolescents and 230 adults participating in the Mexican National Health and Nutrition Survey-2012.Validity was evaluated using correlation coefficients (CC),deattenuated CC, linear regression models, cross-classification analysis, and the Bland-Altman method. In adults, deattenuated correlation coefficients between the SFFQ and the 24DRs ranged from 0.30 for folate to 0.61 for saturated fat. In addition, 63% adults and 62% adolescents were classified in the same and adjacent quartile of nutrient intake when comparing data from SFFQ and 24DRs. The SFFQ had moderate validity for energy, macronutrients and micronutrients. It also had good validity to rank individuals according to their dietary intake of different nutrients.
Leite, Priscilla; Rangé, Bernard; Kukar-Kiney, Monika; Ridgway, Nancy; Monroe, Kent; Ribas Junior, Rodolfo; Landeira Fernandez, J; Nardi, Antonio Egidio; Silva, Adriana
2013-03-01
To present the process of transcultural adaptation of the Richmond Compulsive Buying Scale to Brazilian Portuguese. For the semantic adaptation step, the scale was translated to Portuguese and then back-translated to English by two professional translators and one psychologist, without any communication between them. The scale was then applied to 20 participants from the general population for language adjustments. For the construct validation step, an exploratory factor analysis was performed, using the scree plot test, principal component analysis for factor extraction, and Varimax rotation. For convergent validity, the correlation matrix was analyzed through Pearson's coefficient. The scale showed easy applicability, satisfactory internal consistency (Cronbach's alpha=.87), and a high correlation with other rating scales for compulsive buying disorder, indicating that it is suitable to be used in the assessment and diagnosis of compulsive buying disorder, as it presents psychometric validity. The Brazilian Portuguese version of the Richmond Compulsive Buying Scale has good validity and reliability.
[Evaluation of Suicide Risk Levels in Hospitals: Validity and Reliability Tests].
Macagnino, Sandro; Steinert, Tilman; Uhlmann, Carmen
2018-05-01
Examination of in-hospital suicide risk levels concerning their validity and their reliability. The internal suicide risk levels were evaluated in a cross sectional study of in 163 inpatients. A reliability check was performed via determining interrater-reliability of senior physician, therapist and the responsible nurse. Within the scope of the validity check, we conducted analyses of criterion validity and construct validity. For the total sample an "acceptable" to "good" interrater-reliability (Kendalls W = .77) of suicide risk levels were obtained. Schizophrenic disorders showed the lowest values, for personality disorders we found the highest level of interrater-reliability. When examining the criterion validity, Item-9 of the BDI-II is substantial correlated to our suicide risk levels (ρ m = .54, p < .01). Within the scope of construct validity check, affective disorders showed the highest correlation (ρ = .77), compatible also with "convergent validity". They differed with schizophrenic disorders which showed the least concordance (ρ = .43). In-hospital suicide risk levels may represent an important contribution to the assessment of suicidal behavior of inpatients experiencing psychiatric treatment due to their overall good validity and reliability. © Georg Thieme Verlag KG Stuttgart · New York.
Alqarni, Ayidh M; Vennu, Vishal; Alshammari, Sulaiman A; Bindawas, Saad M
2018-01-01
Older adults are the fastest growing population group worldwide. Regular physical activity (PA) is reported to reduce the risk of health conditions and improve personal well-being. Few validated instruments can be used to measure the PA levels among older adults in Saudi Arabia. The Physical Activity Scale for the Elderly (PASE) is used worldwide for evaluating the PA levels of the elderly in epidemiological studies. However, this scale has not been translated into Arabic. This study aimed to cross-culturally adapt the PASE into Arabic language and evaluate its reliability and validity among community-dwelling older adults in Saudi Arabia. This study was a cross-sectional one following Beaton guidelines to translate and perform cultural adaptation, as well as test the reliability and validity of the PASE Arabic version (PASE-A). Elderly (N=74) people from both genders, who lived in a community dwelling in Riyadh city, were selected from several primary health care centers. The study used Cronbach's alpha coefficient to assess the internal consistency reliability, while intraclass correlation coefficient (ICC 2,1 ) was used for test-retest reliability and the Spearman's rank correlation coefficient ( r ) was used to evaluate the correlation among PASE-A and grip strength, Timed Up and Go test, body mass index, and fat percentage. Out of 74 older adults, 59 (79.7%) completed the PASE-A questionnaire twice. The internal consistency of the PASE-A components was good (Cronbach's alpha 0.70-0.75), and the reliability of the components was excellent (ICC 2,1 0.90-0.98). A higher PASE-A score was associated with higher grip strength ( r =0.28, p =0.05) and with shorter Timed Up and Go test times ( r =-0.45, p =0.01). The PASE-A version was easy, understandable, and relevant for Saudi older adults' culture. This scale was a reliable and valid tool for evaluating and assessing the PA level among community-dwelling older adults in Saudi Arabia.
Torabi, Hadi; Khoddami, Seyyedeh Maryam; Ansari, Noureddin Nakhostin; Dabirmoghaddam, Payman
2016-11-01
To cross-culturally adapt of Persian Vocal Tract Discomfort (VTDp) scale and evaluate its validity and reliability in the assessment of patients with muscle tension dysphonia (MTD). A cross-sectional and prospective cohort design was used to psychometrically test the VTDp. The VTD scale was cross-culturally adapted into Persian language following standard forward-backward translations. The VTDp scale was administrated to 100 patients with MTD (54 men and 46 women; mean age: 38.05 ± 10.02 years) and 50 healthy volunteers (26 men and 24 women; mean age: 36.50 ± 12.27 years). Forty-five patients with MTD completed the VTDp 7 days later for test-retest reliability. Patients also completed the Persian Voice Handicap Index (VHIp) to assess construct validity. The results of discriminative validity demonstrated that the VTDp was able to discriminate between patients with MTD and healthy participants. The internal consistency was confirmed with Cronbach α .77 and 0.73 for VTDp frequency and severity subscales, respectively. The test-retest reliability was excellent with an intraclass correlation coefficient (ICC agreement ) of 0.93 for the frequency subscale and 0.91 for the severity subscale. Construct validity of the VTDp was shown with significant correlations between the VTDp frequency and severity subscales and the VHIp total scores (0.36 and 0.37, respectively). The standard error of measurement and smallest detectable change values for VTDp frequency (2.11 and 5.85, respectively) and severity (2.25 and 6.23, respectively) were acceptable. The Bland-Altman analysis for assessing the agreement between test and retest measurements showed no systematic bias. The VTDp is a valid and reliable self-administered scale to measure patient's vocal tract sensations in Persian-speaking population. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Translation and validation of the Cardiac Depression Scale to Arabic.
Papasavvas, T; Al-Amin, H; Ghabrash, H F; Micklewright, D
2016-08-01
The Cardiac Depression Scale (CDS) has been designed to measure depressive symptoms in patients with heart disease. There is no Arabic version of the CDS. We translated and validated the CDS in an Arabic sample of patients with heart disease. Forward and back translation of the CDS was followed by assessment of cultural relevance and content validity. The Arabic version of the CDS (A-CDS) and the Arabic version of the Hospital Anxiety and Depression Scale (A-HADS) were then administered to 260 Arab in-patients with heart disease from 18 Arabic countries. Construct validity was assessed using exploratory factor analysis with polychoric correlations. Internal consistency was assessed using ordinal reliability alpha and item-to-factor polychoric correlations. Concurrent validity was assessed using Pearson's correlation coefficient between the A-CDS and the depression subscale of the A-HADS (A-HADS-D). Cultural relevance and content validity of the A-CDS were satisfactory. Exploratory factor analysis revealed three robust factors, without cross-loadings, that formed a single dimension. Internal consistency was high (ordinal reliability alpha for the total scale and the three factors were .94, .91, .86, and .87, respectively; item-to-factor correlations ranged from .77 to .91). Concurrent validity was high (r=.72). The A-CDS demonstrated a closer to normal distribution of scores than the A-HADS-D. Sensitivity and specificity of the A-CDS were not objectively assessed. The A-CDS appears to be a valid and reliable instrument to measure depressive symptoms in a representative sample of Arab in-patients with heart disease. Copyright © 2016 Elsevier B.V. All rights reserved.
de Souza, Clarissa Vasconcellos; Vigorito, Afonso Celso; Miranda, Eliana C M; Garcia, Celso; Colturato, Vergílio Antonio Rensi; Mauad, Marcos Augusto; Moreira, Maria Cláudia Rodrigues; da Silva Bouzas, Luis Fernando; Lermontov, Simone; Hamerschlak, Nelson; Rodrigues, Morgani; de Almeida Barros, Jose Carlos; Chiattone, Ricardo; Lee, Stephanie J; Flowers, Mary ED
2017-01-01
The Lee chronic graft-versus-disease (cGVHD) Symptom Scale is a patient-reported instrument developed and validated in English to measure symptoms and functional impact of cGVHD. This tool has not been validated in a Latin America population. The Brazil-Seattle Chronic GVHD Consortium conducted a multicenter study at five Brazilian institutions to validate the Lee cGVHD Symptom Scale in adults with chronic GVHD. Study objectives included the translation and validation of the instrument in Brazilian Portuguese and evaluation of the correlation with other quality of life (QoL) tools (i.e., Medical Outcomes Study Short Form 36 [SF-36] and the Functional Assessment of Chronic Illness Therapy with Bone Marrow Transplant subscale [FACT-BMT]). Translation and validation were according to the American Association of Orthopedic Surgeons Outcome Committee guideline. Spearman’s correlation coefficient was used to measure construct validity. Reliability was assessed using Cronbach’s alpha and intraclass correlation coefficients. Between April 2011 and August 2012, 47 patients with cGVHD by the 2005 NIH criteria were enrolled in this study. Cohort median age was 48 (23–69) years and 29 (62%) were male. Lee cGVHD Symptom Scale reliability was adequate (Cronbach’s alpha 0.62–0.83). The correlations between similar domains of the Lee cGVHD Symptom Scale, SF-36 and FACT-BMT were moderate to high. The Brazilian Portuguese version of the Lee cGVHD Symptom Scale is valid and reliable and can be used in clinical trials of cGVHD in Brazil. PMID:27058616
[Cross-cultural adaptation and validation of the Dizziness Handicap Inventory: Argentine version].
Caldara, Betina; Asenzo, Adriana I; Brusotti Paglia, Gabriela; Ferreri, Eliana; Gomez, Ramiro S; Laiz, Mariela M; Luques, María L; Mangoni, Ana P; Marazzi, Carla; Matesa, María A; Peker, Guillermo; Pratto, Romina A; Quiroga, Cecilia E; Rapela, Laura; Ruiz, Vanesa R; Sanchez, Noelia; Taglioretti, Célide L; Tana, Andrés M; Zandstra, Ingrid V
2012-01-01
The Dizziness Handicap Inventory is a useful tool for quantifying self-perceived handicap in patients with vertigo, dizziness or unsteadiness and its impact on daily living activities. The Dizziness Handicap Inventory identifies functional, physical and emotional disorders related to balance disturbance. Our objective was to cross-culturally adapt the Peninsular Spanish version of the Dizziness Handicap Inventory for use in Argentina and validate the adapted Argentinian version. We included both healthy subjects and patients with vertigo, dizziness or unsteadiness, aged 18 to 85 years, native Spanish-speaking Argentinians. We introduced linguistic and cultural modifications to the Peninsular Spanish version to obtain the Argentinian one. This version was given twice to 108 patients, 24 to 72 h apart. Internal consistency, test-retest reliability and construct validity were assessed using a visual analogue scale, the Romberg test, the tandem Romberg test and the tandem gait test. We found high internal consistency (α=0.87) and very high test-retest reliability for the total Dizziness Handicap Inventory score (intraclass correlation coefficient: 0.98) and its subscales. The total Dizziness Handicap Inventory and the functional subscale were found to correlate significantly with the Romberg and tandem Romberg tests. The emotional subscale showed a significant correlation with the Romberg test and the eyes-open tandem Romberg test (P<.05) The Argentinian version of the Dizziness Handicap Inventory proved to be a reliable and valid tool to quantify self-perceived handicap resulting from vertigo, dizziness or unsteadiness. Copyright © 2011 Elsevier España, S.L. All rights reserved.
Stapelfeldt, Christina Malmose; Momsen, Anne-Mette Hedeager; Lund, Thomas; Grønborg, Therese Koops; Hogg-Johnson, Sheilah; Jensen, Chris; Skakon, Janne; Labriola, Merete
2018-06-06
The objective of the present study was to translate and validate the Canadian Readiness for Return To Work instrument (RRTW-CA) into a Danish version (RRTWDK) by testing its test-retest and internal consistency reliability and its structural and construct validity. Cross-cultural adaptation of the six-staged RRTW-CA instrument was performed in a standardised, systematic five-step-procedure; forward translation, panel synthesis of the translation, back translation, consolidation and revision by researchers, and finally pre-testing. This RRTW-DK beta-version was tested for its psychometric properties by intra-class correlation coefficient and standard error of measurement (n = 114), Cronbach's alpha (n = 471), confirmatory factor analyses (n = 373), and Spearman's rank correlation coefficient (n = 436) in sickness beneficiaries from a municipal employment agency and hospital wards. The original RRTW-CA stage structure could not be confirmed in the RRTWDK. The psychometric properties were thus inconclusive. The RRTW-DK cannot be recommended for use in the current version as the RRTW construct is questionable. The RRTW construct needs further exploration, preferably in a population that is homogeneous with regard to cause of sickness, disability duration and age.
Goel, Honey; Sinha, V R; Thareja, Suresh; Aggarwal, Saurabh; Kumar, Manoj
2011-08-30
The quinolones belong to a family of synthetic potent broad-spectrum antibiotics and particularly active against gram-negative organisms, especially Pseudomonas aeruginosa. A 3D-QSPkR approach has been used to obtain the quantitative structure pharmacokinetic relationship for a series of quinolone drugs using SOMFA. The series consisting of 28 molecules have been investigated for their pharmacokinetic performance using biological half life (t(1/2)). A statistically validated robust model for a diverse group of quinolone drugs having flexibility in structure and pharmacokinetic profile (t(1/2)) obtained using SOMFA having good cross-validated correlation coefficient r(cv)(2) (0.6847), non cross-validated correlation coefficient r(2) values (0.7310) and high F-test value (33.9663). Analysis of 3D-QSPkR models through electrostatic and shape grids provide useful information about the shape and electrostatic potential contributions on t(1/2). The analysis of SOMFA results provide an insight for the generation of novel molecular architecture of quinolones with optimal half life and improved biological profile. Copyright © 2011 Elsevier B.V. All rights reserved.
Sathira-Angkura, Vera; Pithankuakul, Kongkit; Sakulpipatana, Susana; Piyaskulkaew, Chaiwat; Kunakornsawat, Sombat
2012-04-20
Cross-sectional observational study to investigate psychometric properties of an adapted Thai version of the refined Scoliosis Research Society-22 (SRS-22) questionnaire. To evaluate the reliability and validity of the adapted Thai version of the refined SRS-22 questionnaire. The SRS-22 questionnaire is a valid instrument for assessing the health-related quality of life for patients with adolescent idiopathic scoliosis. Recently, the questionnaire has been translated and validated in many languages for non-English-speaking countries. Translation/retranslation of the English version of the SRS-22 was conducted, and the cross-cultural adaptation process was performed. The Thai version SRS-22 and previously validated Thai version Short-Form survey version 2.0 (SF-36V2) questionnaires were administered to 77 patients with adolescent idiopathic scoliosis who had surgical treatment. Fifty-eight patients (52 adolescent girls) had filled out the first set of questionnaires. Thirty patients of the first-time responders completed the second set of questionnaires. The mean age at the time of operation was 14.6 years and the mean age at the time of the final follow-up was 18.7 years. The mean preoperative scoliosis curve magnitude was 55.4° (range, 30°-95°) and postoperative curve magnitude was 20.1° (range, 0°-60°). Internal consistency was determined with Cronbach α coefficient. Intraclass correlation coefficient was used for test-retest reliability. Concurrent validity was evaluated by comparing SRS-22 domains with relevant domains in the SF-36V2 questionnaire, using the Pearson correlation coefficient. The mean overall Cronbach α coefficient of the adapted Thai version SRS-22 was 0.76. The 2 of corresponding domains (mental health = 0.80 and self-image = 0.83) had satisfactory internal consistency and the remaining domains (pain = 0.78; function/activity = 0.74; and satisfaction = 0.76) were good. The intraclass correlation coefficient for 5 domains was ranged from 0.79 to 0.90, which demonstrated the satisfactory test/retest reproducibility. The concurrent validity, determined by the Pearson correlation coefficient between SRS-22 and SF-36V2 domains, had a good correlation for 15 relevant comparisons (r = 0.50-0.75). The adapted Thai version of the SRS-22 questionnaire had validity and reliability, which can be used to assess the outcome of treatment among Thai-speaking patients with adolescent idiopathic scoliosis.
Marlatt, K L; Greenway, F L; Ravussin, E
2017-04-01
Comparison of percent fat mass across different body composition analysis devices is important given variation in technology accuracy and precision, as well as the growing need for cross-validation of devices often applied across longitudinal studies. We compared EchoMRI-AH and Lunar iDXA quantification of percent body fat (PBF) in 84 adults (43M, 41F), with the mean age 39.7±15.9 years and body mass index (BMI) 26.2±5.3 kg/m 2 . PBF correlated strongly between devices (r>0.95, P<0.0001). A prediction equation was derived in half of the subjects, and the other half were used to cross-validate the proposed equation (EchoMRI-AH PBF=[(0.94 × iDXA PBF)+(0.14 × Age)+(3.3 × Female)-8.83). The mean PBF difference (predicted-measured) in the validation group was not different from 0 (diff=0.27%, 95% confidence interval: -0.42-0.96, P=0.430). Bland-Altman plots showed a bias with higher measured PBF on EchoMRI-AH versus iDXA in all 84 subjects (β=0.13, P<0.0001). The proposed prediction equation was valid in our cross-validation sample, and it has the potential to be applied across multicenter studies.
Cross-Cultural Adaptation and Validation of the Back Beliefs Questionnaire to the Arabic Language.
Alamrani, Samia; Alsobayel, Hana; Alnahdi, Ali H; Moloney, Niamh; Mackey, Martin
2016-06-01
Translation, cross-cultural adaptation, and psychometric testing. To translate the Back Beliefs Questionnaire (BBQ) into Arabic and investigate its psychometric properties in an Arabic-speaking sample of individuals with low back pain (LBP). Back pain beliefs are associated with pain chronicity and disability in people with LBP. The BBQ is a recognized and frequently used tool for measuring these beliefs. To date the BBQ has not been translated into Arabic. The English version of the BBQ was translated and culturally adapted into Arabic (BBQ-Ar) according to published guidelines. The BBQ-Ar was then tested in a sample of 115 Arabic-speaking individuals with LBP. Reliability was evaluated through internal consistency (Cronbach α) and test-retest reliability (intraclass correlation coefficient), the latter in a subgroup of 25. Construct validity was assessed using exploratory factor analysis and by examining the correlation between the BBQ-Ar, the Oswestry Disability Index and a Numerical Pain Rating Scale. Internal consistency of the BBQ-Ar was good (Cronbach α = 0.77). Test-retest reliability was good (intraclass correlation coefficient [2,1] = 0.88). Exploratory factor analysis revealed a three-factor structure, explaining 46% of total variance, with the first factor alone explaining 24%. Eight of the nine scoring items were loaded on the first factor thus forming a unidimensional scale. A significant negative correlation was found between Oswestry Disability Index and BBQ-Ar scores (r = -0.307; P < 0.01), whereas no significant correlation was found between BBQ-Ar and Pain Rating Scale scores. No floor or celling effects were observed. The BBQ-Ar is a valid and reliable tool that can be used to assess back pain beliefs in Arabic-speaking individuals. N/A.
NASA Astrophysics Data System (ADS)
Forsyth, C.; Rae, I. J.; Mann, I. R.; Pakhotin, I. P.
2017-03-01
Field-aligned currents (FACs) are a fundamental component of coupled solar wind-magnetosphere-ionosphere. By assuming that FACs can be approximated by stationary infinite current sheets that do not change on the spacecraft crossing time, single-spacecraft magnetic field measurements can be used to estimate the currents flowing in space. By combining data from multiple spacecraft on similar orbits, these stationarity assumptions can be tested. In this technical report, we present a new technique that combines cross correlation and linear fitting of multiple spacecraft measurements to determine the reliability of the FAC estimates. We show that this technique can identify those intervals in which the currents estimated from single-spacecraft techniques are both well correlated and have similar amplitudes, thus meeting the spatial and temporal stationarity requirements. Using data from European Space Agency's Swarm mission from 2014 to 2015, we show that larger-scale currents (>450 km) are well correlated and have a one-to-one fit up to 50% of the time, whereas small-scale (<50 km) currents show similar amplitudes only 1% of the time despite there being a good correlation 18% of the time. It is thus imperative to examine both the correlation and amplitude of the calculated FACs in order to assess both the validity of the underlying assumptions and hence ultimately the reliability of such single-spacecraft FAC estimates.
Gülgöz, S
2001-01-01
The cross-cultural validity of the Need for Cognition Scale and its relationship with cognitive performance were investigated in two studies. In the first study, the relationships between the scale and university entrance scores, course grades, study skills, and social desirability were examined. Using the short form of the Turkish version of the Need for Cognition Scale (S. Gülöz & C. J. Sadowski, 1995) no correlation with academic performance was found but there was significant correlation with a study skills scale and a social desirability scale created for this study. When regression analysis was used to predict grade point average, the Need for Cognition Scale was a significant predictor. In the second study, participants low or high in need for cognition solved multiple-solution anagrams. The instructions preceding the task set the participants' expectations regarding task difficulty. An interaction between expectation and need for cognition indicated that participants with low need for cognition performed worse when they expected difficult problems. Results of the two studies showed that need for cognition has cross-cultural validity and that its effect on cognitive performance was mediated by other variables.
The City of Hope-Quality of Life-Ostomy Questionnaire: Persian Translation and Validation
Anaraki, F; Vafaie, M; Behboo, R; Esmaeilpour, S; Maghsoodi, N; Safaee, A; Grant, M
2014-01-01
Background: Since there is no disease-specific instrument for measuring quality-of-life (QOL) in Ostomy patients in Persian language. Aim: This study was designed to translate and evaluate the validity and reliability of City of Hope-quality of life-Ostomy questionnaire (COH-QOL-Ostomy questionnaire). Subjects and Methods: This study was designed as cross-sectional study. Reliability of the subscales and the summary scores were demonstrated by intra-class correlation coefficients. Pearson's correlations of an item with its own scale and other scales were calculated to evaluated convergent and discriminant validity. Clinical validity was also evaluated by known-group comparisons. Results: Cronbach's alpha coefficient for all subscales was about 0.70 or higher. Results of interscale correlation were satisfactory and each subscale only measured a single and specified trait. All subscales met the standards of convergent and discriminant validity. Known group comparison analysis showed significant differences in social and spiritual well-being. Conclusion: The findings confirmed the reliability and validity of Persian version of COH-QOL-Ostomy questionnaire. The instrument was also well received by the Iranian patients. It can be considered as a valuable instrument to assess the different aspects of health related quality-of-life in Ostomy patients and used in clinical research in the future. PMID:25221719
Validity of the FACT-H&N (v 4.0) among Malaysian oral cancer patients.
Doss, J G; Thomson, W M; Drummond, B K; Raja Latifah, R J
2011-07-01
To assess the cross-sectional construct validity of the Malay-translated and cross-culturally adapted FACT-H&N (v 4.0) for discriminative use in a sample of Malaysian oral cancer patients. A cross-sectional study of adults newly diagnosed with oral cancer. HRQOL data were collected using the FACT-H&N (v 4.0), a global question and a supplementary set of eight questions ('MAQ') obtained earlier in pilot work. Of the 76 participants (61.8% female; 23.7% younger than 50), most (96.1%) had oral squamous cell carcinoma; two-thirds were in Stages III or IV. At baseline, patients' mean FACT summary (FACT-G, FACT-H&N, FACT-H&N TOI, and FHNSI) and subscale (pwb, swb, ewb, fwb, and hnsc) scores were towards the higher end of the range. Equal proportions (36.8%) rated their overall HRQOL as 'good' or 'average'; fewer than one-quarter rated it as 'poor', and only two as 'very good'. All six FACT summary and most subscales had moderate-to-good internal consistency. For all summary scales, those with 'very poor/poor' self-rated HRQOL differed significantly from the 'good/very good' group. All FACT summary scales correlated strongly (r>0.75). Summary scales showed convergent validity (r>0.90) but little discriminant validity. The discriminant validity of the FHNSI improved with the addition of the MAQ. The FACT-H&N summary scales and most subscales demonstrated acceptable cross-sectional construct validity, reliability and discriminative ability, and thus appear appropriate for further use among Malaysian oral cancer patients. Copyright © 2011 Elsevier Ltd. All rights reserved.
Dragomir-Daescu, Dan; Buijs, Jorn Op Den; McEligot, Sean; Dai, Yifei; Entwistle, Rachel C.; Salas, Christina; Melton, L. Joseph; Bennet, Kevin E.; Khosla, Sundeep; Amin, Shreyasee
2013-01-01
Clinical implementation of quantitative computed tomography-based finite element analysis (QCT/FEA) of proximal femur stiffness and strength to assess the likelihood of proximal femur (hip) fractures requires a unified modeling procedure, consistency in predicting bone mechanical properties, and validation with realistic test data that represent typical hip fractures, specifically, a sideways fall on the hip. We, therefore, used two sets (n = 9, each) of cadaveric femora with bone densities varying from normal to osteoporotic to build, refine, and validate a new class of QCT/FEA models for hip fracture under loading conditions that simulate a sideways fall on the hip. Convergence requirements of finite element models of the first set of femora led to the creation of a new meshing strategy and a robust process to model proximal femur geometry and material properties from QCT images. We used a second set of femora to cross-validate the model parameters derived from the first set. Refined models were validated experimentally by fracturing femora using specially designed fixtures, load cells, and high speed video capture. CT image reconstructions of fractured femora were created to classify the fractures. The predicted stiffness (cross-validation R2 = 0.87), fracture load (cross-validation R2 = 0.85), and fracture patterns (83% agreement) correlated well with experimental data. PMID:21052839
Cross-validated detection of crack initiation in aerospace materials
NASA Astrophysics Data System (ADS)
Vanniamparambil, Prashanth A.; Cuadra, Jefferson; Guclu, Utku; Bartoli, Ivan; Kontsos, Antonios
2014-03-01
A cross-validated nondestructive evaluation approach was employed to in situ detect the onset of damage in an Aluminum alloy compact tension specimen. The approach consisted of the coordinated use primarily the acoustic emission, combined with the infrared thermography and digital image correlation methods. Both tensile loads were applied and the specimen was continuously monitored using the nondestructive approach. Crack initiation was witnessed visually and was confirmed by the characteristic load drop accompanying the ductile fracture process. The full field deformation map provided by the nondestructive approach validated the formation of a pronounced plasticity zone near the crack tip. At the time of crack initiation, a burst in the temperature field ahead of the crack tip as well as a sudden increase of the acoustic recordings were observed. Although such experiments have been attempted and reported before in the literature, the presented approach provides for the first time a cross-validated nondestructive dataset that can be used for quantitative analyses of the crack initiation information content. It further allows future development of automated procedures for real-time identification of damage precursors including the rarely explored crack incubation stage in fatigue conditions.
Li, Zhenghua; Cheng, Fansheng; Xia, Zhining
2011-01-01
The chemical structures of 114 polycyclic aromatic sulfur heterocycles (PASHs) have been studied by molecular electronegativity-distance vector (MEDV). The linear relationships between gas chromatographic retention index and the MEDV have been established by a multiple linear regression (MLR) model. The results of variable selection by stepwise multiple regression (SMR) and the powerful predictive abilities of the optimization model appraised by leave-one-out cross-validation showed that the optimization model with the correlation coefficient (R) of 0.994 7 and the cross-validated correlation coefficient (Rcv) of 0.994 0 possessed the best statistical quality. Furthermore, when the 114 PASHs compounds were divided into calibration and test sets in the ratio of 2:1, the statistical analysis showed our models possesses almost equal statistical quality, the very similar regression coefficients and the good robustness. The quantitative structure-retention relationship (QSRR) model established may provide a convenient and powerful method for predicting the gas chromatographic retention of PASHs.
Urdu version of the neck disability index: a reliability and validity study.
Farooq, Muhammad Nazim; Mohseni-Bandpei, Mohammad A; Gilani, Syed Amir; Hafeez, Ambreen
2017-04-08
Despite the wide use of the neck disability index (NDI) for assessing disability in patients with neck pain, the NDI has not yet been translated and validated in Urdu. The first purpose of the present study was to translate and cross-culturally adapt the NDI into the Urdu language (NDI-U). The second purpose was to investigate the reliability, validity and responsiveness of the NDI-U in Urdu-speaking patients experiencing chronic mechanical neck pain (CMNP). Translation and cross-cultural adaptation of the original version of the NDI were carried out using previously described procedures. Seventy-six patients with CMNP and thirty healthy participants were recruited for the study. NDI-U and visual analogue scales for pain intensity (VAS pain ) and disability (VAS disability ) were administered to all the participants at baseline and to the patients 3 weeks after receiving physiotherapy intervention. The global rating of change scale (GROC) was also administered at this time. Test-retest reliability and internal consistency were carried out on forty-six randomly selected patients two days after they completed the NDI-U. The NDI-U was evaluated for factor analysis, content validity, construct validity (discriminative and convergent validity) and responsiveness. An intra-class correlation coefficient (ICC 2,1 ) revealed excellent test-retest reliability for all items (ICC 2,1 = 0.86-0.98) and total scores (ICC 2,1 = 0.99) of the NDI-U. The NDI-U was found internally consistent with a Cronbach's alpha of 0.90 and a fair to good correlation between single items and the NDI-U total scores (r = 0.34 to 0.89). Factor analysis of the NDI-U produced two factors explaining 66.71% of the variance. Content validity was good, as no floor or ceiling effects were detected for the NDI-U total score. To determine discriminative validity, an independent t-test revealed a significant difference in the NDI-U total scores between the patients and healthy controls (P < 0.001). For convergent validity, Pearson's correlation coefficient showed a strong correlation between NDI-U and VAS disability (r = 0.83, P < 0.001) and a moderate correlation between NDI-U and VAS pain (r = 0.62, P < 0.001). To measure responsiveness, an independent t-test showed a significant difference in the NDI-U change scores between the stable and the improved groups (P < 0.001). Furthermore, moderate correlations were found between the NDI-U change scores and the GROC (r = 0.50, P < 0.001), VAS disability change scores (r = 0.58, P < 0.001) and VAS pain change scores (r = 0.55, P < 0.001). The results showed that the NDI-U is a reliable, valid and responsive questionnaire to measure disability in Urdu-speaking patients with CMNP.
Psychometric validation of a condom self-efficacy scale in Korean.
Cha, EunSeok; Kim, Kevin H; Burke, Lora E
2008-01-01
When an instrument is translated for use in cross-cultural research, it needs to account for cultural factors without distorting the psychometric properties of the instrument. To validate the psychometric properties of the condom self-efficacy scale (CSE) originally developed for American adolescents and young adults after translating the scale to Korean (CSE-K) to determine its suitability for cross-cultural research among Korean college students. A cross-sectional, correlational design was used with an exploratory survey methodology through self-report questionnaires. A convenience sample of 351 students, aged 18 to 25 years, were recruited at a university in Seoul, Korea. The participants completed the CSE-K and the intention of condom use scales after they were translated from English to Korean using a combined translation technique. A demographic and sex history questionnaire, which included an item to assess actual condom usage, was also administered. Mean, variance, reliability, criterion validity, and factorial validity using confirmatory factor analysis were assessed in the CSE-K. Norms for the CSE-K were similar, but not identical, to norms for the English version. The means of all three subscales were lower for the CSE-K than for the original CSE; however, the obtained variance in CSE-K was roughly similar with the original CSE. The Cronbach's alpha coefficient for the total scale was higher for the CSE-K (.91) than that for either the CSE (.85) or CSE in Thai (.85). Criterion validity and construct validity of the CSE-K were confirmed. The CSE-K was a reliable and valid scale in measuring condom self-efficacy among Korean college students. The findings suggest that the CSE was an appropriate instrument to conduct cross-cultural research on sexual behavior in adolescents and young adults.
Frischholz, Edward J; Tryon, Warren W; Spiegel, Herbert; Fisher, Stanley
2015-01-01
Hilgard's comment raises some important issues, although many of these have little to do with the primary purpose of the study under discussion. This purpose was to objectively examine the relationship between three conceptually and operationally different procedures for measuring hypnotic responsivity. Hilgard's concern over the magnitude of the correlation between the HIP and SHSS:C is unfounded. A cross-validated correlation of .66 was found between the HIP and SHSS:C in a new sample of 44 student volunteers. This demonstrates that the HIP correlates about the same with SHSS:C as the Harvard Group Scale of Hypnotic Susceptibility. Hilgard's conception of the Eye-Roll (ER) hypothesis is clarified. Evidence which utilizes all cases in the correlational analysis is presented in support of the ER hypothesis. Happily, we all agree on a new methodology which will be definitive in testing the validity of the ER hypothesis.
Lee, Jennifer; Koh, Jung Hee; Kwok, Seung-Ki; Park, Sung-Hwan
2016-05-01
This study was conducted to generate and validate a cross-culturally adapted Korean version of the xerostomia inventory (XI), an 11-item questionnaire designed to measure the severity of xerostomia. The original English version of the XI was translated into Korean according to the guidelines for cross-cultural adaptation of health-related quality-of-life measures. Among a prospective cohort of primary Sjögren's syndrome (pSS) in Korea, 194 patients were analyzed. Internal consistency was evaluated by using Cronbach's alpha, and test-retest reliability was obtained by using an intraclass correlation coefficient (ICC) analysis. Construct validity was investigated by performing a correlation analysis between XI total score and salivary flow rate (SFR). Cronbach's alpha for internal consistency was 0.868, and the ICC for test-retest reliability ranged from 0.48 to 0.827, with a median value of 0.72. Moderate negative correlations between XI score and stimulated SFR, unstimulated SFR, and differential (stimulated minus unstimulated) SFR were observed (Spearman's rho, ρ = -0.515, -0.447, and -0.482, respectively; P < 0.001). The correlation analysis between the visual analogue scale (VAS) score of overall dryness and SFR indicated a smaller ρ value (-0.235 [P = 0.006], -0.243 [P = 0.002], and -0.252 [P = 0.003], respectively), which supports that XI more accurately reflects the degree of xerostomia in the pSS patients. In conclusion, the Korean version of the XI is a reliable tool to estimate the severity of xerostomia in patients with pSS.
Validity and reliability of Arabic MOS social support survey.
Dafaalla, Mohamed; Farah, Abdulraheem; Bashir, Sheima; Khalil, Ammar; Abdulhamid, Rabab; Mokhtar, Mousab; Mahadi, Mohamed; Omer, Zulfa; Suliman, Asgad; Elkhalifa, Mohammed; Abdelgadir, Hanin; Kheir, Abdelmoneim E M; Abdalrahman, Ihab
2016-01-01
We aimed to generate a valid reliable Arabic version of MOS social support survey (MOS-SSS). We did a cross sectional study in medical students of Faculty of Medicine in Khartoum, Sudan. We did a clustered random sampling in 500 students of which 487 were suitable for analysis. We followed the standard translation process for translating the MOS-SSS. We accomplished factor analysis to assess construct validity, and generated item-scales correlations to evaluate the convergent and discriminant validity. We extracted the Cronbach's α and Spearman Brown coefficient of spit half method to determine internal consistency. We measured stability by correlation between the scores of the MOS survey taken at two different occasions with ten days apart in 252 participants. All items correlated highly (0.788 or greater) with their hypothesized scales. All items in subscales correlated higher by two standard errors with their own scale than with any other scale. Principle component analysis with varimax rotation was conducted on the 19 items and examination of scree plot graphically suggested 4 predominant factors that account for 72 % of variance. It showed high loadings, ranging from 0.720 to 0.84 for items of emotional support, 0.699-0.845 for tangible support, 0.518-0.823 for affectionate support, and 0.740-0.816 for positive social interaction. Cronbach's alpha for overall MOS scale and subscales indicated high internal consistency. The test-retest correlation showed weak correlation between the test and retest (ranges from 0.04 to 0.104). The Arabic MOS-SSS had high validity and internal consistency.
Sattler, Tine; Sekulic, Damir; Spasic, Miodrag; Osmankac, Nedzad; Vicente João, Paulo; Dervisevic, Edvin; Hadzic, Vedran
2016-01-01
Previous investigations noted potential importance of isokinetic strength in rapid muscular performances, such as jumping. This study aimed to identify the influence of isokinetic-knee-strength on specific jumping performance in volleyball. The secondary aim of the study was to evaluate reliability and validity of the two volleyball-specific jumping tests. The sample comprised 67 female (21.96±3.79 years; 68.26±8.52 kg; 174.43±6.85 cm) and 99 male (23.62±5.27 years; 84.83±10.37 kg; 189.01±7.21 cm) high- volleyball players who competed in 1st and 2nd National Division. Subjects were randomly divided into validation (N.=55 and 33 for males and females, respectively) and cross-validation subsamples (N.=54 and 34 for males and females, respectively). Set of predictors included isokinetic tests, to evaluate the eccentric and concentric strength capacities of the knee extensors, and flexors for dominant and non-dominant leg. The main outcome measure for the isokinetic testing was peak torque (PT) which was later normalized for body mass and expressed as PT/Kg. Block-jump and spike-jump performances were measured over three trials, and observed as criteria. Forward stepwise multiple regressions were calculated for validation subsamples and then cross-validated. Cross validation included correlations between and t-test differences between observed and predicted scores; and Bland Altman graphics. Jumping tests were found to be reliable (spike jump: ICC of 0.79 and 0.86; block-jump: ICC of 0.86 and 0.90; for males and females, respectively), and their validity was confirmed by significant t-test differences between 1st vs. 2nd division players. Isokinetic variables were found to be significant predictors of jumping performance in females, but not among males. In females, the isokinetic-knee measures were shown to be stronger and more valid predictors of the block-jump (42% and 64% of the explained variance for validation and cross-validation subsample, respectively) than that of the spike-jump (39% and 34% of the explained variance for validation and cross-validation subsample, respectively). Differences between prediction models calculated for males and females are mostly explained by gender-specific biomechanics of jumping. Study defined importance of knee-isokinetic-strength in volleyball jumping performance in female athletes. Further studies should evaluate association between ankle-isokinetic-strength and volleyball-specific jumping performances. Results reinforce the need for the cross-validation of the prediction-models in sport and exercise sciences.
Doubova, Svetlana V; Aguirre-Hernandez, Rebeca; Gutiérrez-de la Barrera, Marcos; Infante-Castañeda, Claudia; Pérez-Cuevas, Ricardo
2015-09-01
The purpose of this study is to validate the Mexican version of the Short-Form Supportive Care Needs survey (SCNS-SFM). A cross-sectional survey was conducted from June to December 2013 at the Oncology Hospital of the Mexican Institute of Social Security in Mexico City. The study included 825 subsequent cancer patients >20 years of age with all forms of solid cancer. Patients had prior surgical removal of histologically confirmed cancer and attended outpatient consultations. Validation of SCNS-SFM included the following: (1) content validity through a group of experts; (2) construct validity through an exploratory factor analysis based on the polychoric correlation matrix; (3) internal consistency using Cronbach's alpha; (4) convergent validity between SCNS-SFM and quality of life, anxiety, and depression scales by calculating Pearson's correlation coefficient; (5) discriminative validity through analysis of MANOVAs; and (6) test-retest reliability using intraclass correlation coefficient calculations. SCNS-SFM has 33 items with five factors accounting for 59 % of total variance. Cronbach's alpha values ranged from 0.78 to 0.90 among factors. SCNS-SFM has good convergent validity compared with quality of life and depression and anxiety scales and good discriminative validity, revealing great information, psychological support, and physical daily living needs for women, patients <60 years, and high physical daily living needs for those with <1 year since cancer diagnosis, with advanced disease stages and current chemo- or radiotherapy. Intraclass correlation coefficient between SCNS-SFM measurements was 0.9. SCNS-SFM has acceptable psychometric properties and is suitable to evaluate supportive care needs of cancer patients.
Singh, Varun Pratap; Singh, Rajkumar
2014-03-01
The aim of this study was to develop a reliable and valid Nepali version of the Psychosocial Impact of Dental Aesthetic Questionnaire (PIDAQ). Cross-sectional descriptive validation study. B.P. Koirala Institute of Health Sciences, Dharan, Nepal. A rigorous translation process including conceptual and semantic evaluation, translation, back translation and pre-testing was carried out. Two hundred and fifty-two undergraduates, including equal numbers of males and females with an age ranging from 18 to 29 years (mean age: 22·33±2·114 years), participated in this study. Reliability was assessed by Cronbach's alpha coefficient and the coefficient of correlation was used to assess correlation between items and test-retest reliability. The construct validity was tested by factorial analysis. Convergent construct validity was tested by comparison of PIDAQ scores with the aesthetic component of the index of orthodontic treatment needs (IOTN-AC) and perception of occlusion scale (POS), respectively. Discriminant construct validity was assessed by differences in score for those who demand treatment and those who did not. The response rate was 100%. One hundred and twenty-three individuals had a demand for orthodontic treatment. The Nepali PIDAQ had excellent reliability with Cronbach's alpha of 0·945, corrected item correlation between 0·525 and 0·790 and overall test-retest reliability of 0·978. The construct validity was good with formation of a new sub-domain 'Dental self-consciousness'. The scale had good correlation with IOTN-AC and POS fulfilling convergent construct validity. The discriminant construct validity was proved by significant differences in scores for subjects with demand and without demand for treatment. To conclude, Nepali version of PIDAQ has good psychometric properties and can be used effectively in this population group for further research.
Reliability and Validity of the Greek Migraine Disability Assessment (MIDAS) Questionnaire.
Oikonomidi, Theodora; Vikelis, Michail; Artemiadis, Artemios; Chrousos, George P; Darviri, Christina
2018-03-01
The Migraine Disability Assessment (MIDAS) Questionnaire is a reliable and valid instrument for migraine-related disability. Such a tool is needed to quantify migraine-related disability in the Greek population. This validation study aims to assess the test-retest reliability, internal consistency, item discriminant and convergent validity of the Greek translation of the MIDAS. Adults diagnosed with migraine completed the MIDAS Questionnaire on two occasions 3 weeks apart to assess reliability, and completed the RAND-36 to assess validity. Participants (n = 152) had a median MIDAS score of 24 and mostly severe disability (58% were grade IV). The test-retest reliability analysis (N = 59) revealed excellent reliability for the total score. Internal consistency was α = 0.71 for initial and α = 0.82 for retest completion. For item discriminant validity, the correlations between each question and the total score were significant, with high correlations for questions 2-5 (range 0.67 ≤ r ≤ 0.79; p < 0.01). For convergent validity, there was significant negative correlation between the total score and all RAND-36 subscales except for 'emotional wellbeing'. The negative correlation indicates that patients with a lower degree of disability according to their MIDAS score tended to have better wellbeing. Psychometric properties are comparable with those of other published validation studies of the MIDAS and the original. Findings on question 1 show that missing work/school days may be closely related with increased affect issues. The Greek version of the MIDAS Questionnaire has good reliability and validity. This study allowed for cross-cultural comparability of research findings.
Mbada, Chidozie Emmanuel; Adeogun, Gafar Atanda; Ogunlana, Michael Opeoluwa; Adedoyin, Rufus Adesoji; Akinsulore, Adesanmi; Awotidebe, Taofeek Oluwole; Idowu, Opeyemi Ayodiipo; Olaoye, Olumide Ayoola
2015-09-14
The Short-Form Health Survey (SF-36) is a valid quality of life tool often employed to determine the impact of medical intervention and the outcome of health care services. However, the SF-36 is culturally sensitive which necessitates its adaptation and translation into different languages. This study was conducted to cross-culturally adapt the SF-36 into Yoruba language and determine its reliability and validity. Based on the International Quality of Life Assessment project guidelines, a sequence of translation, test of item-scale correlation, and validation was implemented for the translation of the Yoruba version of the SF-36. Following pilot testing, the English and the Yoruba versions of the SF-36 were administered to a random sample of 1087 apparently healthy individuals to test validity and 249 respondents completed the Yoruba SF-36 again after two weeks to test reliability. Data was analyzed using Pearson's product moment correlation analysis, independent t-test, one-way analysis of variance, multi trait scaling analysis and Intra-Class Correlation (ICC) at p < 0.05. The concurrent validity scores for scales and domains ranges between 0.749 and 0.902 with the highest and lowest scores in the General Health (0.902) and Bodily Pain (0.749) scale. Scale-level descriptive result showed that all scale and domain scores had negative skewness ranging from -2.08 to -0.98. The mean scores for each scales ranges between 83.2 and 88.8. The domain scores for Physical Health Component and Mental Health Component were 85.6 ± 13.7 and 85.9 ± 15.4 respectively. The convergent validity was satisfactory, ranging from 0.421 to 0.907. Discriminant validity was also satisfactory except for item '1'. The ICC for the test-retest reliability of the Yoruba SF-36 ranges between 0.636 and 0.843 for scales; and 0.783 and 0.851 for domains. The data quality, concurrent and discriminant validity, reliability and internal consistency of the Yoruba version of the SF-36 are adequate and it is recommended for measuring health-related quality of life among Yoruba population.
Pechorro, Pedro; Ribeiro da Silva, Diana; Andershed, Henrik; Rijo, Daniel; Abrunhosa Gonçalves, Rui
2016-01-01
The aim of the present study was to examine the psychometric properties of the Youth Psychopathic Traits Inventory (YPI) among a mixed-gender sample of 782 Portuguese youth (M = 15.87 years; SD = 1.72), in a school context. Confirmatory factor analysis revealed the expected three-factor first-order structure. Cross-gender measurement invariance and cross-sample measurement invariance using a forensic sample of institutionalized males were also confirmed. The Portuguese version of the YPI demonstrated generally adequate psychometric properties of internal consistency, mean inter-item correlation, convergent validity, discriminant validity, and criterion-related validity of statistically significant associations with conduct disorder symptoms, alcohol abuse, drug use, and unprotected sex. In terms of known-groups validity, males scored higher than females, and males from the school sample scored lower than institutionalized males. The use of the YPI among the Portuguese male and female youth population is psychometrically justified, and it can be a useful measure to identify adolescents with high levels of psychopathic traits. PMID:27571095
Zhang, Shuang; Xue, Xiwen; Zhang, Liangren; Zhang, Lihe; Liu, Zhenming
2015-12-01
In the past decade, the discovery, synthesis, and evaluation for hundreds of CD38 covalent and non-covalent inhibitors has been reported sequentially by our group and partners; however, a systematic structure-based guidance is still lacking for rational design of CD38 inhibitor. Here, we carried out a comparative analysis of pharmacophore features and quantitative structure-activity relationships for CD38 inhibitors. The results uncover that the essential interactions between key residues and covalent/non-covalent CD38 inhibitors include (i) hydrogen bond and hydrophobic interactions with residues Glu226 and Trp125, (ii) electrostatic or hydrogen bond interaction with the positively charged residue Arg127 region, and (iii) the hydrophobic interaction with residue Trp189. For covalent inhibitors, besides the covalent effect with residue Glu226, the electrostatic interaction with residue Arg127 is also necessary, while another hydrogen/non-bonded interaction with residues Trp125 and Trp189 can also be detected. By means of the SYBYL multifit alignment function, the best CoMFA and CoMSIA with CD38 covalent inhibitors presented cross-validated correlation coefficient values (q(2)) of 0.564 and 0.571, and non-cross-validated values (r(2)) of 0.967 and 0.971, respectively. The CD38 non-covalent inhibitors can be classified into five groups according to their chemical scaffolds, and the residues Glu226, Trp189, and Trp125 are indispensable for those non-covalent inhibitors binding to CD38, while the residues Ser126, Arg127, Asp155, Thr221, and Phe222 are also important. The best CoMFA and CoMSIA with the F12 analogues presented cross-validated correlation coefficient values (q(2)) of 0.469 and 0.454, and non-cross-validated values (r(2)) of 0.814 and 0.819, respectively. © 2015 John Wiley & Sons A/S.
Cross-Cultural Adaptation of the Male Genital Self-Image Scale in Iranian Men.
Saffari, Mohsen; Pakpour, Amir H; Burri, Andrea
2016-03-01
Certain sexual health problems in men can be attributed to genital self-image. Therefore, a culturally adapted version of a Male Genital Self-Image Scale (MGSIS) could help health professionals understand this concept and its associated correlates. To translate the original English version of the MGSIS into Persian and to assess the psychometric properties of this culturally adapted version (MGSIS-I) for use in Iranian men. In total, 1,784 men were recruited for this cross-sectional study. Backward and forward translations of the MGSIS were used to produce the culturally adapted version. Reliability of the MGSIS-I was assessed using Cronbach α and intra-class correlation coefficients. Divergent and convergent validities were examined using Pearson correlation and known-group validity was assessed in subgroups of participants with different sociodemographic statuses. Factor validity of the scale was investigated using exploratory and confirmatory factor analyses. Demographic information, the International Index of Erectile Function, the Body Appreciation Scale, the Rosenberg Self-Esteem Scale, and the MGSIS. Mean age of participants was 38.13 years (SD = 11.45) and all men were married. Cronbach α of the MGSIS-I was 0.89 and interclass correlation coefficients ranged from 0.70 to 0.94. Significant correlations were found between the MGSIS-I and the International Index of Erectile Function (P < .01), whereas correlation of the scale with non-similar scales was lower than with similar scale (confirming convergent and divergent validity). The scale could differentiate between subgroups in age, smoking status, and income (known-group validity). A single-factor solution that explained 70% variance of the scale was explored using exploratory factor analysis (confirming uni-dimensionality); confirmatory factor analysis indicated better fitness for the five-item version than the seven-item version of the MGSIS-I (root mean square error of approximation = 0.05, comparative fit index > 1.00 vs root mean square error of approximation = 0.10, comparative fit index > 0.97, respectively). The MGSIS-I is a useful instrument to assess genital self-image in Iranian men, a concept that has been associated with sexual function. Further investigation is needed to identify the applicability of the scale in other cultures or populations. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Vosoughi, Amir Reza; Roustaei, Narges; Mahdaviazad, Hamideh
2018-06-01
The use of valid and reliable outcome rating scales is essential for evaluating the result of different treatments and interventions. The purposes of this study were to translate and culturally adapt the American Orthopaedic Foot and Ankle Society ankle-hindfoot scale (AOFAS-AHFS) into Persian languages and evaluate its psychometric properties. Forward-backward translation and cultural adaptation method were used to develop Persian version of AOFAS-AHFS. From March to July 2016, one hundred consecutive patients with ankle and hindfoot injuries were included. Internal consistency and reproducibility were evaluated using Cronbach's alpha, Spearman's rank correlation coefficient and Intraclass correlation coefficient (ICC) respectively. Construct validity reported which compare the outcome rating scale measurements with Short Form-36 (SF-36), also convergent and discriminant validity evaluated using Spearman's rank correlation coefficient. Mean age (SD) of the patients was 41.95±13.45years. Cronbach's α coefficient, Spearman's rho and ICC values were 0.71, 0.89 and 0.90 respectively. Total score of AOFAS-AHFS and SF-36 domains has a correlation ranged between 0.17-0.55. Spearman's rank correlation coefficient of 0.4 was exceeded by all items with the exception of stability. The Spearman's rank correlation between each item in functional subscales with its own subscales was higher than the correlation between these items and other subscales. Persian version of AOFAS-AHFS provides additional reliable and valid instrument which can be used to assess broad range of patients with foot and ankle disorders that speaking in Persian. However, it seems that the original version of AOFAS-AHFS needs some revisions. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Stenneberg, Martijn S; Busstra, Harm; Eskes, Michel; van Trijffel, Emiel; Cattrysse, Erik; Scholten-Peeters, Gwendolijne G M; de Bie, Rob A
2018-04-01
There is a lack of valid, reliable, and feasible instruments for measuring planar active cervical range of motion (aCROM) and associated 3D coupling motions in patients with neck pain. Smartphones have advanced sensors and appear to be suitable for these measurements. To estimate the concurrent validity and interrater reliability of a new iPhone application for assessing planar aCROM and associated 3D coupling motions in patients with neck pain, using an electromagnetic tracking device as a reference test. Cross-sectional study. Two samples of neck pain patients were recruited; 30 patients for the validity study and 26 patients for the reliability study. Validity was estimated using intraclass correlation coefficients (ICCs), and by calculating 95% limits of agreement (LoA). To estimate interrater reliability, ICCs were calculated. Cervical 3D coupling motions were analyzed by calculating the cross-correlation coefficients and ratio between the main motions and coupled motions for both instruments. ICCs for concurrent validity and interrater reliability ranged from 0.90 to 0.99. The width of the 95% LoA ranged from about 5° for right lateral bending to 11° for total rotation. No significant differences were found between both devices for associated coupling motion analysis. The iPhone application appears to be a useful discriminative tool for the measurement of planar aCROM and associated coupling motions in patients with neck pain. It fulfills the need for a valid, reliable, and feasible instrument in clinical practice and research. Therapists and researchers should consider measurement error when interpreting scores. Copyright © 2017 Elsevier Ltd. All rights reserved.
Munkácsy, Gyöngyi; Sztupinszki, Zsófia; Herman, Péter; Bán, Bence; Pénzváltó, Zsófia; Szarvas, Nóra; Győrffy, Balázs
2016-09-27
No independent cross-validation of success rate for studies utilizing small interfering RNA (siRNA) for gene silencing has been completed before. To assess the influence of experimental parameters like cell line, transfection technique, validation method, and type of control, we have to validate these in a large set of studies. We utilized gene chip data published for siRNA experiments to assess success rate and to compare methods used in these experiments. We searched NCBI GEO for samples with whole transcriptome analysis before and after gene silencing and evaluated the efficiency for the target and off-target genes using the array-based expression data. Wilcoxon signed-rank test was used to assess silencing efficacy and Kruskal-Wallis tests and Spearman rank correlation were used to evaluate study parameters. All together 1,643 samples representing 429 experiments published in 207 studies were evaluated. The fold change (FC) of down-regulation of the target gene was above 0.7 in 18.5% and was above 0.5 in 38.7% of experiments. Silencing efficiency was lowest in MCF7 and highest in SW480 cells (FC = 0.59 and FC = 0.30, respectively, P = 9.3E-06). Studies utilizing Western blot for validation performed better than those with quantitative polymerase chain reaction (qPCR) or microarray (FC = 0.43, FC = 0.47, and FC = 0.55, respectively, P = 2.8E-04). There was no correlation between type of control, transfection method, publication year, and silencing efficiency. Although gene silencing is a robust feature successfully cross-validated in the majority of experiments, efficiency remained insufficient in a significant proportion of studies. Selection of cell line model and validation method had the highest influence on silencing proficiency.
Development of estrogen receptor beta binding prediction model using large sets of chemicals.
Sakkiah, Sugunadevi; Selvaraj, Chandrabose; Gong, Ping; Zhang, Chaoyang; Tong, Weida; Hong, Huixiao
2017-11-03
We developed an ER β binding prediction model to facilitate identification of chemicals specifically bind ER β or ER α together with our previously developed ER α binding model. Decision Forest was used to train ER β binding prediction model based on a large set of compounds obtained from EADB. Model performance was estimated through 1000 iterations of 5-fold cross validations. Prediction confidence was analyzed using predictions from the cross validations. Informative chemical features for ER β binding were identified through analysis of the frequency data of chemical descriptors used in the models in the 5-fold cross validations. 1000 permutations were conducted to assess the chance correlation. The average accuracy of 5-fold cross validations was 93.14% with a standard deviation of 0.64%. Prediction confidence analysis indicated that the higher the prediction confidence the more accurate the predictions. Permutation testing results revealed that the prediction model is unlikely generated by chance. Eighteen informative descriptors were identified to be important to ER β binding prediction. Application of the prediction model to the data from ToxCast project yielded very high sensitivity of 90-92%. Our results demonstrated ER β binding of chemicals could be accurately predicted using the developed model. Coupling with our previously developed ER α prediction model, this model could be expected to facilitate drug development through identification of chemicals that specifically bind ER β or ER α .
Lindahl, Marianne; Andersen, Signe; Joergensen, Annette; Frandsen, Christian; Jensen, Liselotte; Benedikz, Eirikur
2018-01-01
The aim of this study was to translate and culturally adapt the Short Musculoskeletal Function Assessment (SMFA) into Danish (SMFA-DK) and assess the psychometric properties. SMFA was translated and cross-culturally adapted according to a standardized procedure. Minor changes in the wording in three items were made to adapt to Danish conditions. Acute patients (n = 201) and rehabilitation patients (n = 231) with musculoskeletal problems aged 18-87 years were included. The following analysis were made to evaluate psychometric quality of SMFA-DK: Reliability with Chronbach's alpha, content validity as coding according to the International Classification of Functioning, Disability and Health (ICF), floor/ceiling effects, construct validity as factor analysis, correlations between SMFA-DK and Short Form 36 and also known group method. Responsiveness and effect size were calculated. Cronbach's alpha values were between 0.79 and 0.94. SMFA-DK captured all components of the ICF, and there were no floor/ceiling effects. Factor analysis demonstrated four subscales. SMFA-DK correlated good with the SF-36 subscales for the rehabilitation patients and lower for the newly injured patients. Effect sizes were excellent and better for SMFA-DK than for SF-36. The study indicates that SMFA-DK can be a valid and responsive measure of outcome in rehabilitation settings.
Comparing ordinary kriging and inverse distance weighting for soil as pollution in Beijing.
Qiao, Pengwei; Lei, Mei; Yang, Sucai; Yang, Jun; Guo, Guanghui; Zhou, Xiaoyong
2018-06-01
Spatial interpolation method is the basis of soil heavy metal pollution assessment and remediation. The existing evaluation index for interpolation accuracy did not combine with actual situation. The selection of interpolation methods needs to be based on specific research purposes and research object characteristics. In this paper, As pollution in soils of Beijing was taken as an example. The prediction accuracy of ordinary kriging (OK) and inverse distance weighted (IDW) were evaluated based on the cross validation results and spatial distribution characteristics of influencing factors. The results showed that, under the condition of specific spatial correlation, the cross validation results of OK and IDW for every soil point and the prediction accuracy of spatial distribution trend are similar. But the prediction accuracy of OK for the maximum and minimum is less than IDW, while the number of high pollution areas identified by OK are less than IDW. It is difficult to identify the high pollution areas fully by OK, which shows that the smoothing effect of OK is obvious. In addition, with increasing of the spatial correlation of As concentration, the cross validation error of OK and IDW decreases, and the high pollution area identified by OK is approaching the result of IDW, which can identify the high pollution areas more comprehensively. However, because the semivariogram constructed by OK interpolation method is more subjective and requires larger number of soil samples, IDW is more suitable for spatial prediction of heavy metal pollution in soils.
Crawford, John R; Henry, Julie D
2003-06-01
To provide UK normative data for the Depression Anxiety and Stress Scale (DASS) and test its convergent, discriminant and construct validity. Cross-sectional, correlational and confirmatory factor analysis (CFA). The DASS was administered to a non-clinical sample, broadly representative of the general adult UK population (N = 1,771) in terms of demographic variables. Competing models of the latent structure of the DASS were derived from theoretical and empirical sources and evaluated using confirmatory factor analysis. Correlational analysis was used to determine the influence of demographic variables on DASS scores. The convergent and discriminant validity of the measure was examined through correlating the measure with two other measures of depression and anxiety (the HADS and the sAD), and a measure of positive and negative affectivity (the PANAS). The best fitting model (CFI =.93) of the latent structure of the DASS consisted of three correlated factors corresponding to the depression, anxiety and stress scales with correlated error permitted between items comprising the DASS subscales. Demographic variables had only very modest influences on DASS scores. The reliability of the DASS was excellent, and the measure possessed adequate convergent and discriminant validity Conclusions: The DASS is a reliable and valid measure of the constructs it was intended to assess. The utility of this measure for UK clinicians is enhanced by the provision of large sample normative data.
Vincent, Joshua Israel; Macdermid, Joy Christine; Grewal, Ruby; Sekar, Vincent Prabhakaran; Balachandran, Dinesh
2014-01-01
Prospective longitudinal validation study. To translate and cross-culturally adapt the Oswestry Disability Index (ODI) to the Tamil language (ODI-T), and to evaluate its reliability and construct validity. ODI is widely used as a disease specific questionnaire in back pain patients to evaluate pain and disability. A thorough literature search revealed that the Tamil version of the ODI has not been previously published. The ODI was translated and cross-culturally adapted to the Tamil language according to established guidelines. 30 subjects (16 women and 14 men) with a mean age of 42.7 years (S.D. 13.6; Range 22 - 69) with low back pain were recruited to assess the psychometric properties of the ODI-T Questionnaire. Patients completed the ODI-T, Roland-Morris disability questionnaire (RMDQ), VAS-pain and VAS-disability at baseline and 24-72 hours from the baseline visit. The ODI-T displayed a high degree of internal consistency, with a Cronbach's alpha of 0.92. The test-retest reliability was high (n=30) with an ICC of 0.92 (95% CI, 0.84 to 0.96) and a mean re-test difference of 2.6 points lower on re-test. The ODI-T scores exhibited a strong correlation with the RMDQ scores (r = 0.82) p<0.01, VAS-P (r = 0.78) p<0.01 and VAS-D (r = 0.81) p<0.01. Moderate to low correlations were observed between the ODI-T and lumbar ROM (r = -0.27 to -0.53). All the hypotheses that were constructed apriori were supported. The Tamil version of the ODI Questionnaire is a valid and reliable tool that can be used to measure subjective outcomes of pain and disability in Tamil speaking patients with low back pain.
Alanazi, Fahad; Gleeson, Peggy; Olson, Sharon; Roddey, Toni
2017-04-01
Prospective cohort study of a cross-cultural low back pain (LBP) questionnaire OBJECTIVE.: The objectives of the present study were to translate and cross-culturally adapt the Fear-Avoidance Beliefs Questionnaire (FABQ) to create a version in Arabic and to test its psychometric properties. The FABQ measures the effects that fear and avoidance beliefs have on work and on physical activity. An FABQ cross-culturally adapted for Arabic readers and speakers was created by forward translation, translation synthesis, and backward translation. Forty patients in Riyadh, Saudi Arabia, with LBP evaluated use of the questionnaire, and 70 patients from the same hospital participated in reliability, validity, and sensitivity studies. To determine test-retest reliability of the Arabic FABQ, patients completed it twice within 48 hours without receiving any active treatment between these two sessions. Patients completed the Arabic FABQ (and three other scales) at baseline and 14 days later to determine its validity and sensitivity. Test-retest reliability was good (FABQ-work: intraclass coefficient [ICC] = 0.74; FABQ-physical activity: ICC = 0.90; FABQ overall: ICC = 0.76). Correlations between the FABQ and three other instruments for measuring pain and disability were weak. The strongest correlation was found at the follow-up session with the Arabic Oswestry Questionnaire (r = 0.283; P ≤ 0.05). Sensitivity to change was low. The translation and adaptation of the Arabic version of the FABQ was successful. Overall, the Arabic FABQ had good test-retest reliability, acceptable construct validity, and low sensitivity to change. The Arabic version of the FABQ shows promise in the assessment of fear-avoidance beliefs among patients with LBP who speak and read Arabic. 3.
McDermott, A; Visentin, G; De Marchi, M; Berry, D P; Fenelon, M A; O'Connor, P M; Kenny, O A; McParland, S
2016-04-01
The aim of this study was to evaluate the effectiveness of mid-infrared spectroscopy in predicting milk protein and free amino acid (FAA) composition in bovine milk. Milk samples were collected from 7 Irish research herds and represented cows from a range of breeds, parities, and stages of lactation. Mid-infrared spectral data in the range of 900 to 5,000 cm(-1) were available for 730 milk samples; gold standard methods were used to quantify individual protein fractions and FAA of these samples with a view to predicting these gold standard protein fractions and FAA levels with available mid-infrared spectroscopy data. Separate prediction equations were developed for each trait using partial least squares regression; accuracy of prediction was assessed using both cross validation on a calibration data set (n=400 to 591 samples) and external validation on an independent data set (n=143 to 294 samples). The accuracy of prediction in external validation was the same irrespective of whether undertaken on the entire external validation data set or just within the Holstein-Friesian breed. The strongest coefficient of correlation obtained for protein fractions in external validation was 0.74, 0.69, and 0.67 for total casein, total β-lactoglobulin, and β-casein, respectively. Total proteins (i.e., total casein, total whey, and total lactoglobulin) were predicted with greater accuracy then their respective component traits; prediction accuracy using the infrared spectrum was superior to prediction using just milk protein concentration. Weak to moderate prediction accuracies were observed for FAA. The greatest coefficient of correlation in both cross validation and external validation was for Gly (0.75), indicating a moderate accuracy of prediction. Overall, the FAA prediction models overpredicted the gold standard values. Near-unity correlations existed between total casein and β-casein irrespective of whether the traits were based on the gold standard (0.92) or mid-infrared spectroscopy predictions (0.95). Weaker correlations among FAA were observed than the correlations among the protein fractions. Pearson correlations between gold standard protein fractions and the milk processing characteristics of rennet coagulation time, curd firming time, curd firmness, heat coagulating time, pH, and casein micelle size were weak to moderate and ranged from -0.48 (protein and pH) to 0.50 (total casein and a30). Pearson correlations between gold standard FAA and these milk processing characteristics were also weak to moderate and ranged from -0.60 (Val and pH) to 0.49 (Val and K20). Results from this study indicate that mid-infrared spectroscopy has the potential to predict protein fractions and some FAA in milk at a population level. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Schadl, Kornél; Vassar, Rachel; Cahill-Rowley, Katelyn; Yeom, Kristin W; Stevenson, David K; Rose, Jessica
2018-01-01
Advanced neuroimaging and computational methods offer opportunities for more accurate prognosis. We hypothesized that near-term regional white matter (WM) microstructure, assessed on diffusion tensor imaging (DTI), using exhaustive feature selection with cross-validation would predict neurodevelopment in preterm children. Near-term MRI and DTI obtained at 36.6 ± 1.8 weeks postmenstrual age in 66 very-low-birth-weight preterm neonates were assessed. 60/66 had follow-up neurodevelopmental evaluation with Bayley Scales of Infant-Toddler Development, 3rd-edition (BSID-III) at 18-22 months. Linear models with exhaustive feature selection and leave-one-out cross-validation computed based on DTI identified sets of three brain regions most predictive of cognitive and motor function; logistic regression models were computed to classify high-risk infants scoring one standard deviation below mean. Cognitive impairment was predicted (100% sensitivity, 100% specificity; AUC = 1) by near-term right middle-temporal gyrus MD, right cingulate-cingulum MD, left caudate MD. Motor impairment was predicted (90% sensitivity, 86% specificity; AUC = 0.912) by left precuneus FA, right superior occipital gyrus MD, right hippocampus FA. Cognitive score variance was explained (29.6%, cross-validated Rˆ2 = 0.296) by left posterior-limb-of-internal-capsule MD, Genu RD, right fusiform gyrus AD. Motor score variance was explained (31.7%, cross-validated Rˆ2 = 0.317) by left posterior-limb-of-internal-capsule MD, right parahippocampal gyrus AD, right middle-temporal gyrus AD. Search in large DTI feature space more accurately identified neonatal neuroimaging correlates of neurodevelopment.
Santo, Ruth Miyuki; Ribeiro-Ferreira, Felipe; Alves, Milton Ruiz; Epstein, Jonathan; Novaes, Priscila
2015-04-01
To provide a reliable, validated, and culturally adapted instrument that may be used in monitoring dry eye in Brazilian patients and to discuss the strategies for the enhancement of the cross-cultural adaptation and validation process of a self-report measure for dry eye. The cross-cultural adaptation process (CCAP) of the original Ocular Surface Disease Index (OSDI) into Brazilian-Portuguese was conducted using a 9-step guideline. The synthesis of translations was tested twice, for face and content validity, by different subjects (focus groups and cognitive interviews). The expert committee contributed on several steps, and back translations were based on the final rather than the prefinal version. For validation, the adapted version was applied in a prospective longitudinal study to 101 patients from the Dry Eye Clinic at the General Hospital of the University of São Paulo, Brazil. Simultaneously to the OSDI, patients answered the short form-36 health survey (SF-36) and the 25-item visual function questionnaire (VFQ-25) and underwent clinical evaluation. Internal consistency, test-retest reliability, and measure validity were assessed. Cronbach's alpha value of the cross-culturally adapted Brazilian-Portuguese version of the OSDI was 0.905, and the intraclass correlation coefficient was 0.801. There was a statistically significant difference between OSDI scores in patients with dry eye (41.15 ± 27.40) and without dry eye (17.88 ± 17.09). There was a negative association between OSDI and VFQ-25 total score (P < 0.01) and between the OSDI and five SF-36 domains. OSDI scores correlated positively with lissamine green and fluorescein staining scores (P < 0.001) and negatively with Schirmer test I and tear break-up time values (P < 0.001). Although most of the reviewed guidelines on CCAP involve well-defined steps (translation, synthesis/reconciliation, back translation, expert committee review, pretesting), the proposed methodological steps have not been applied in a uniform way. The translation and adaptation process requires skill, knowledge, experience, and a considerable investment of time to maximize the attainment of semantic, idiomatic, experiential, and conceptual equivalence between the source and target questionnaires. A well-established guideline resulted in a culturally adapted Brazilian-Portuguese version of the OSDI, tested and validated on a sample of Brazilian population, and proved to be a valid and reliable instrument for assessing patients with dry eye syndrome in Brazil. Copyright © 2015 Elsevier Inc. All rights reserved.
Lupi, Jaqueline Basilio; Carvalho de Abreu, Daniela Cristina; Ferreira, Mariana Candido; Oliveira, Renê Donizeti Ribeiro de; Chaves, Thais Cristina
2017-08-01
This study aimed to culturally adapt and validate the Revised Fibromyalgia Impact Questionnaire (FIQR) to Brazilian Portuguese, by the use of analysis of internal consistency, reliability, and construct and structural validity. A total of 100 female patients with fibromyalgia participated in the validation process of the Brazilian Portuguese version of the FIQR (FIQR-Br).The intraclass correlation coefficient (ICC) was used for statistical analysis of reliability (test-retest), Cronbach's alpha for internal consistency, Pearson's rank correlation for construct validity, and confirmatory factor analysis (CFA) for structural validity. It was verified excellent levels of reliability, with ICC greater than 0.75 for all questions and domains of the FIQR-Br. For internal consistency, alpha values greater than 0.70 for the items and domains of the questionnaire were observed. Moderate (0.40 < r < 0.70) and strong (r > 0.70) correlations were observed for the scores of domains and total score between the FIQR-Br and FIQ-Br. The structure of the three domains of the FIQR-Br was confirmed by CFA. The results of this study suggest that that the FIQR-Br is a reliable and valid instrument for assessing fibromyalgia-related impact, and supports its use in clinical settings and research. The structure of the three domains of the FIQR-Br was also confirmed. Implications for Rehabilitation Fibromyalgia is a chronic musculoskeletal disorder characterized by widespread and diffuse pain, fatigue, sleep disturbances, and depression. The disease significantly impairs patients' quality of life and can be highly disabling. To be used in multicenter research efforts, the Revised Fibromyalgia Impact Questionnaire (FIQR) must be cross-culturally validated and psychometrically tested. This paper will make available a new version of the FIQR-Br since another version already exists, but there are concerns about its measurement properties. The availability of an instrument adapted to and validated for Brazilian Portuguese may make it possible to reliably verify the effects of rehabilitation programs on disability from fibromyalgia. The FIQR-Br showed results comparable with other versions of the FIQR in other languages, thereby enabling comparison of effects of rehabilitation interventions on disability from fibromyalgia conducted in Brazil with results of studies carried out in other parts of the world.
Duracinsky, Martin; Lalanne, Christophe; Le Coeur, Sophie; Herrmann, Susan; Berzins, Baiba; Armstrong, Andrew Richard; Lau, Joseph Tak Fai; Fournier, Isabelle; Chassany, Olivier
2012-04-15
This study reports the psychometric validation of a new HIV/AIDS-specific health-related quality of life (HRQL) questionnaire, the Patient Reported Outcomes Quality of Life-HIV. The instrument was developed simultaneously across Europe, North and South America, Africa, Asia, and Australia to assess multidimensional quality of life impairments in the era of highly active antiretroviral therapy. A cross-sectional study was performed in 8 countries. The pilot 70-item questionnaire was co-administered with the HIV symptoms index, the EQ-5D and Medical Outcomes Study-HIV questionnaires. Demographic and biomedical data were collected. After item analysis and reduction, convergent discriminant concurrent validity and known-group validity were examined. Internal consistency and reliability scores were assessed using Cronbach alpha and intraclass correlation. The final sample of 791 patients was composed of 64% males (median age: 41 years, HIV diagnosis = 5 years), 13.8% were treatment naive. Item reduction yielded a 43-item form surveying 8 dimensions and 1 global health item that showed good convergent and discriminant validity and reliability (98% scaling success; Cronbach alphas 0.77-0.89). Correlations with EQ-5D and Medical Outcomes Study-HIV complied with concurrent validity expectations; likewise, correlations against the number of self-reported symptoms and depression showed good support for criterion validity. A test-retest study on French patients (n = 34) showed temporal stability (intraclass correlation coefficient = 0.86). Significant and meaningful differences of HRQL scores between countries were found. The Patient Reported Outcomes Quality of Life-HIV questionnaire is a valid and reliable instrument for assessing HRQL specific to HIV disease in different cultures and healthcare systems.
The High School & Beyond Data Set: Academic Self-Concept Measures.
ERIC Educational Resources Information Center
Strein, William
A series of confirmatory factor analyses using both LISREL VI (maximum likelihood method) and LISCOMP (weighted least squares method using covariance matrix based on polychoric correlations) and including cross-validation on independent samples were applied to items from the High School and Beyond data set to explore the measurement…
Validation and cross cultural adaptation of the Italian version of the Harris Hip Score.
Dettoni, Federico; Pellegrino, Pietro; La Russa, Massimo R; Bonasia, Davide E; Blonna, Davide; Bruzzone, Matteo; Castoldi, Filippo; Rossi, Roberto
2015-01-01
The Harris Hip Score (HHS) is one of the most widely used health related quality of life (HRQOL) measures for the assessment of hip pathology: in spite of this, a validation study, and an official Italian version have not been provided yet. The aim of this study was to create an Italian valid and reliable version of the HHS. The score was translated and modified in Italian; then 103 patients with different hip pathologies were evaluated using this HHS version and also with the WOMAC and the SF-12 questionnaires. Content, construct and criterion validities were tested, such as interobserver reliability, test-retest reliability and internal consistency. Cross-cultural adaptation was easy, and only minor adaptation was required in the translation process. Construct and criterion validity of the HHS Italian Version were confirmed by satisfactory values of Spearman's Rho for correlation between specific domains of HHS and Womac and SF12 scores. Interobserver and test-retest reliabilities obtained values of 0.996 and 0.975 respectively; Cronbach's alpha for internal consistency was 0.816. Statistical and clinical analysis showed that HHS is highly valid and reliable in this new Italian version.
Chiu, Tina H T; Huang, Hui-Ya; Chen, Kuan-Ju; Wu, Yu-R U; Chiu, Jason P C; Li, Yi-Hwei; Chiu, Brian C-H; Lin, Chin-Lon; Lin, Ming-Nan
2014-07-01
To assess the relative validity and reproducibility of the quantitative FFQ used in the Tzu Chi Health Study (TCHS). The reproducibility was evaluated by comparing the baseline FFQ with the 2-year follow-up FFQ. The validity was evaluated by comparing the baseline FFQ with 3 d dietary records and biomarkers (serum folate and vitamin B12). Median comparison, cross-classification and Spearman correlation with and without energy adjustment and deattenuation for day-to-day variation were assessed. TCHS is a prospective cohort containing a high proportion of true vegetarians and part-time vegetarians (regularly consuming a vegetarian diet without completely avoiding meat). Subsets of 103, seventy-eight and 1528 TCHS participants were included in the reproducibility, dietary record-validity and biomarker-validity studies, respectively. Correlations assessing the reproducibility for repeat administrations of the FFQ were in the range of 0·46-0·65 for macronutrients and 0·35-0·67 for micronutrients; the average same quartile agreement was 40%. The correlation between FFQ and biomarkers was 0·41 for both vitamin B12 and folate. Moderate to good correlations between the baseline FFQ and dietary records were found for energy, protein, carbohydrate, saturated and monounsaturated fat, fibre, vitamin C, vitamin A, K, Ca, Mg, P, Fe and Zn (average crude correlation: 0·47 (range: 0·37-0·66); average energy-adjusted correlation: 0·43 (range: 0·38-0·55); average energy-adjusted deattenuated correlation: 0·50 (range: 0·44-0·66)) with same quartile agreement rate of 39% (range: 35-45%), while misclassification to the extreme quartile was rare (average: 4% (range: 0-6%)). The FFQ is a reliable and valid tool to rank relative intake of major nutrients for TCHS participants.
van der Lee, J H; Beckerman, H; Knol, D L; de Vet, H C W; Bouter, L M
2004-06-01
The Motor Activity Log (MAL) is a semistructured interview for hemiparetic stroke patients to assess the use of their paretic arm and hand (amount of use [AOU]) and quality of movement [QOM]) during activities of daily living. Scores range from 0 to 5. The following clinimetric properties of the MAL were quantified: internal consistency (Cronbach alpha), test-retest agreement (Bland and Altman method), cross-sectional construct validity (correlation between AOU and QOM and with the Action Research Arm [ARA] test), longitudinal construct validity (correlation of change on the MAL during the intervention with a global change rating [GCR] and with change on the ARA), and responsiveness (effect size). Two baseline measurements 2 weeks apart and 1 follow-up measurement immediately after 2 weeks of intensive exercise therapy either with or without immobilization of the unimpaired arm (forced use) were performed in 56 chronic stroke patients. Internal consistency was high (AOU: alpha=0.88; QOM: alpha=0.91). The limits of agreement were -0.70 to 0.85 and -0.61 to 0.71 for AOU and QOM, respectively. The correlation with the ARA score (Spearman rho) was 0.63 (AOU and QOM). However, the improvement on the MAL during the intervention was only weakly related to the GCR and to the improvement on the ARA, Spearman rho was between 0.16 and 0.22. The responsiveness ratio was 1.9 (AOU) and 2.0 (QOM). The MAL is internally consistent and relatively stable in chronic stroke patients not undergoing an intervention. The cross-sectional construct validity of the MAL is reasonable, but the results raise doubt about its longitudinal construct validity.
Ghezeljeh, Tahereh Najafi; Ardebili, Fatimah Mohades; Rafii, Forough; Hagani, Hamid
2013-09-01
Burn as a traumatic life incident manifests severe pain and psychological problems. Specific instruments are needed to evaluate burn patients' psychological issues related to the injury. The aim of this study was to translate and evaluate the reliability and validity of the Persian versions of Impact of Burn Specific Pain Anxiety scale (BSPAS) and Impact of Event Scale (IES). In this cross-sectional study, convenience sampling method was utilized to select 55 Iranian hospitalized burn patients. Combined translation was utilized for translating scales. Alpha cronbach, item-total correlation, convergent and discriminative validity were evaluated. The Cronbach's α for both BSPAS- and IES-Persian version was 0.96. Item-total correlation coefficients ranged from 0.70 to 0.90. Convergent construct validity was confirmed by indicating high correlation between the scales designed to measure the same concepts. The mean score of BSPAS- and IES-Persian version was lower for individuals with a lower TBSA burn percentage which assessed discriminative construct validity of scales. BSPAS- and IES-Persian version showed high internal consistency and good validity for the assessment of burn psychological outcome in hospitalized burn patients. Future studies are needed to determine repeatability, factor structure, sensitivity and specificity of the scales. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Willeumier, Julie J; van der Wal, C W P G; van der Wal, Robert J P; Dijkstra, P D S; Vliet Vlieland, Thea P M; van de Sande, Michiel A J
2017-01-01
The aim of this study was to translate and culturally adapt the Toronto Extremity Salvage Score (TESS) to Dutch and to validate the translated version. The TESS lower and upper extremity versions (LE and UE) were translated to Dutch according to international guidelines. The translated version was validated in 98 patients with surgically treated bone or soft tissue tumors of the LE or UE. To assess test-retest reliability, participants were asked to fill in a second questionnaire after one week. Construct validity was determined by computing Spearman rank correlations with the Short Form- (SF-) 36. The internal consistency (0.957 and 0.938 for LE and UE, resp.) and test-retest reliability (intraclass correlation coefficients 0.963 and 0.969 for LE and UE, resp.) were good for both questionnaires. The Dutch LE and UE TESS versions correlated most strongly with the SF-36 physical function dimension ( r = 0.737 for LE, 0.726 for UE) and the physical component summary score ( r = 0.811 and 0.797 for LE and UE). The Dutch TESS questionnaire for lower and upper extremities is a consistent, reliable, and valid instrument to measure patient-reported physical function in surgically treated patients with a soft tissue or bone tumor.
Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Razi, Shiva; Mardani-Kivi, Mohsen; Reza Kachooei, Amir
2015-09-01
Oxford shoulder score is a specific 12-item patient-reported tool for evaluation of patients with inflammatory and degenerative disorders of the shoulder. Since its introduction, it has been translated and culturally adapted in some Western and Eastern countries. The aim of this study was to translate the Oxford Shoulder Score (OSS) in Persian and to test its validity and reliability in Persian speaking population in Iran. One hundred patients with degenerative or inflammatory shoulder problem participated in the survey in 2012. All patients completed the Persian version of OSS, Persian DASH and the SF-36 for testing validity. Randomly, 37 patients filled out the Persian OSS again three days after the initial visit to assess the reliability of the questionnaire. Cronbach's alpha coefficient was 0.93. The intraclass correlation coefficient was 0.93. In terms of validity, there was a significant correlation between the Persian OSS and DASH and SF-36 scores (P < 0.001). The Persian version of the OSS proved to be a valid, reliable, and reproducible tool as demonstrated by high Cronbach's alpha and Pearson's correlation coefficients. The Persian transcript of OSS is administrable to Persian speaking patients with shoulder condition and it is understandable by them.
Estrada Álvarez, Jorge M; Ossa García, Ximena; del Quijano del Gordo, Carmen I; Bustos, Luis; Urina, Diana P; Pérez, Celso F; Ossa, John E; Moreno Rojas, Edwin
2015-08-01
To assess the validity and reliability of the chronic respiratory questionnaire (CRQ) in the measurement of HRQL in the Colombian population with COPD. A cross-sectional study was conducted with a sample of 200 patients diagnosed with COPD according to GOLD criteria. Convergence validity was evaluated by correlating the questionnaire results with other clinical variables such as exercise tolerance, forced expiratory volume at the first second (FEV1), and depression levels. HRQL measured through the CRQ correlated significantly with the 6-min walk test (r = 0.34), just as the dimensions fatigue (r = 0.37) and dyspnoea correlated with the FEV1 test (r = 0.21) and the dimensions emotional function and disease management with depression levels (r = -0.79). The Generalized Structured Component Analysis (GSCA) with the prespecified model is showed, and the total variance explained by the items in the model was 61.5 % (FIT = 0.615), unweighted least squares (GFI = 0.998), and standardised root mean square (SRMR = 0.084), indicating that the model fits adequately. The CRQ presents evidence of adequate validity and reliability in the Colombian population. Its use is recommended to measure HRQL in patients with COPD, although future validations will be needed to identify the property of sensitivity to change.
İlçin, Nursen; Gürpınar, Barış; Bayraktar, Deniz; Savcı, Sema; Çetin, Pınar; Sarı, İsmail; Akkoç, Nurullah
2016-01-01
[Purpose] This study describes the cultural adaptation, validation, and reliability of the Turkish version of the Pain Catastrophizing Scale in patients with ankylosing spondylitis. [Methods] The validity of the Turkish version of the Pain Catastrophizing Scale was assessed by evaluating data quality (missing data and floor and ceiling effects), principal components analysis, internal consistency (Cronbach’s alpha), and construct validity (Spearman’s rho). Reproducibility analyses included standard measurement error, minimum detectable change, limits of agreement, and intraclass correlation coefficients. [Results] Sixty-four adult patients with ankylosing spondylitis with a mean age of 42.2 years completed the study. Factor analysis revealed that all questionnaire items could be grouped into two factors. Excellent internal consistency was found, with a Chronbach’s alpha value of 0.95. Reliability analyses showed an intraclass correlation coefficient (95% confidence interval) of 0.96 for the total score. There was a low correlation coefficient between the Turkish version of the Pain Catastrophizing Scale and body mass index, pain levels at rest and during activity, health-related quality of life, and fear and avoidance behaviors. [Conclusion] The results of this study indicate that the Turkish version of the Pain Catastrophizing Scale is a valid and reliable clinical and research tool for patients with ankylosing spondylitis. PMID:26957778
Lohrer, Heinz; Nauck, Tanja
2011-03-01
Clinical measurement study. To cross-culturally adapt and validate the Victorian Institute of Sports Assessment Patellar Tendinopathy Questionnaire (VISA-P) for German-speaking patients. Like most questionnaires, the VISA-P was developed for English-speaking patients. There is a need to adapt the scale for German-speaking patients and thereby add to the total body of psychometric evidence relating to this instrument. The VISA-P questionnaire was translated and cross-culturally adapted into German (VISA-P-G) in 6 steps: translation, synthesis, back translation, expert committee review, pretesting, and advisory committee appraisal. The psychometric properties of the VISA-P-G were determined using 23 patients with patellar tendinopathy and 57 active healthy persons (32 sport students and 25 basketball players). Reliability was evaluated by applying the questionnaire twice within a week to all 80 participants. Known group validity was calculated using a 1-way analysis of variance. Additionally, VISA-P-G results were correlated with the Blazina classification system for patellar tendinopathy, using the Spearman rank correlation coefficient. VISA-P-G ratings from the present study groups were further compared with respective data published in the original English, Dutch, and Swedish versions by a 2-sample t test. Internal consistency for the individual items of the questionnaire was determined within the patient group using a Cronbach alpha. Test-retest revealed excellent reliability for the patient and the asymptomatic control group (ICC = 0.88 and 0.87, respectively). Internal consistency for the patients was 0.88. Concurrent validity was almost perfect (ρ = -0.81; P<.001). The VISA-P-G is a reliable and valid questionnaire for the self-assessment of pain, symptoms, and function in German-speaking patients with patellar tendinopathy. Its psychometric properties are comparable with the original English and international adaptations (Swedish, Dutch, and Italian).
Ko, Jupil; Rosen, Adam B; Brown, Cathleen N
2017-09-12
To cross-culturally adapt the Identification Functional Ankle Instability for use with Korean-speaking participants. The English version of the IdFAI was cross-culturally adapted into Korean based on the guidelines. The psychometric properties in the Korean version of the IdFAI were measured for test-retest reliability, internal consistency, criterion-related validity, discriminative validity, and measurement error 181 native Korean-speakers. Intra-class correlation coefficients (ICC 2,1 ) between the English and Korean versions of the IdFAI for test-retest reliability was 0.98 (standard error of measurement = 1.41). The Cronbach's alpha coefficient was 0.89 for the Korean versions of IdFAI. The Korean versions of the IdFAI had a strong correlation with the SF-36 (r s = -0.69, p < .001) and the Korean version of the Cumberland Ankle Instability Tool (r s = -0.65, p < .001). The cutoff score of >10 was the optimal cutoff score to distinguish between the group memberships. The minimally detectable change of the Korean versions of the IdFAI score was 3.91. The Korean versions of the IdFAI have shown to be an excellent, reliable, and valid instrument. The Korean versions of the IdFAI can be utilized to assess the presence of Chronic Ankle Instability by researchers and clinicians working among Korean-speaking populations. Implications for rehabilitation The high recurrence rate of sprains may result into Chronic Ankle Instability (CAI). The Identification of Functional Ankle Instability Tool (IdFAI) has been validated and recommended to identify patients with Chronic Ankle Instability (CAI). The Korean version of the Identification of Functional Ankle Instability Tool (IdFAI) may be also recommend to researchers and clinicians for assessing the presence of Chronic Ankle Instability (CAI) in Korean-speaking population.
Neuro-QoL health-related quality of life measurement system: Validation in Parkinson's disease.
Nowinski, Cindy J; Siderowf, Andrew; Simuni, Tanya; Wortman, Catherine; Moy, Claudia; Cella, David
2016-05-01
Neuro-QoL is a multidimensional patient-reported outcome measurement system assessing aspects of physical, mental, and social health identified by neurology patients and caregivers as important. One of the first neurology-specific patient-reported outcome measure systems created using modern test development methods, Neuro-Qol enables brief, yet precise, assessment and the ability to conduct both PD-specific and cross-disease comparisons. We present results of Neuro-QoL clinical validation using a sample of PD patients. A total of 120 PD patients recruited from academic medical centers were assessed at baseline, 1 week, and 6 months. Assessments included Neuro-QoL and general and PD-specific validity measures. Participants were 62% male and 95% white (average age = 66); H & Y stages were 1 (16%), 2 (61%), 3 (18%), and 4 (5%). Internal consistency and test-retest reliability of Neuro-QoL ranged from Cronbach's alphas = 0.81 to 0.94 with intraclass correlation coefficients = 0.66 to 0.80. Pearson's correlations between Neuro-QoL and legacy measures were generally moderate and in expected directions. UPDRS Part 2 was moderately correlated with Neuro-QoL Upper Extremity and Mobility, respectively (r's = -0.44; -0.59). Parkinson's Disease Questionnaire-39 and Neuro-QoL measures of similar constructs showed strong-to-moderate correlations (r's = 0.70-0.44). Neuro-QoL measures of fatigue, mobility, positive emotion, and emotional/behavioral control showed responsiveness to self-reported change. Neuro-QoL is valid for use in PD clinical research. Reliability for all but two measures is sufficient for group comparisons, with some evidence supporting responsiveness to change. Neuro-QoL possesses characteristics, such as brevity, flexibility in administration, and suitability, for cross-disease comparisons that may be advantageous to users in a variety of settings. © 2016 Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.
Rosales, Roberto S; Martin-Hidalgo, Yolanda; Reboso-Morales, Luis; Atroshi, Isam
2016-03-03
The purpose of this study was to assess the reliability and construct validity of the Spanish version of the 6-item carpal tunnel syndrome (CTS) symptoms scale (CTS-6). In this cross-sectional study 40 patients diagnosed with CTS based on clinical and neurophysiologic criteria, completed the standard Spanish versions of the CTS-6 and the disabilities of the arm, shoulder and hand (QuickDASH) scales on two occasions with a 1-week interval. Internal-consistency reliability was assessed with the Cronbach alpha coefficient and test-retest reliability with the intraclass correlation coefficient, two way random effect model and absolute agreement definition (ICC2,1). Cross-sectional precision was analyzed with the Standard Error of the Measurement (SEM). Longitudinal precision for test-retest reliability coefficient was assessed with the Standard Error of the Measurement difference (SEMdiff) and the Minimal Detectable Change at 95 % confidence level (MDC95). For assessing construct validity it was hypothesized that the CTS-6 would have a strong positive correlation with the QuickDASH, analyzed with the Pearson correlation coefficient (r). The standard Spanish version of the CTS-6 presented a Cronbach alpha of 0.81 with a SEM of 0.3. Test-retest reliability showed an ICC of 0.85 with a SRMdiff of 0.36 and a MDC95 of 0.7. The correlation between CTS-6 and the QuickDASH was concordant with the a priori formulated construct hypothesis (r 0.69) CONCLUSIONS: The standard Spanish version of the 6-item CTS symptoms scale showed good internal consistency, test-retest reliability and construct validity for outcomes assessment in CTS. The CTS-6 will be useful to clinicians and researchers in Spanish speaking parts of the world. The use of standardized outcome measures across countries also will facilitate comparison of research results in carpal tunnel syndrome.
Uncertainty Quantification Techniques of SCALE/TSUNAMI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rearden, Bradley T; Mueller, Don
2011-01-01
The Standardized Computer Analysis for Licensing Evaluation (SCALE) code system developed at Oak Ridge National Laboratory (ORNL) includes Tools for Sensitivity and Uncertainty Analysis Methodology Implementation (TSUNAMI). The TSUNAMI code suite can quantify the predicted change in system responses, such as k{sub eff}, reactivity differences, or ratios of fluxes or reaction rates, due to changes in the energy-dependent, nuclide-reaction-specific cross-section data. Where uncertainties in the neutron cross-section data are available, the sensitivity of the system to the cross-section data can be applied to propagate the uncertainties in the cross-section data to an uncertainty in the system response. Uncertainty quantification ismore » useful for identifying potential sources of computational biases and highlighting parameters important to code validation. Traditional validation techniques often examine one or more average physical parameters to characterize a system and identify applicable benchmark experiments. However, with TSUNAMI correlation coefficients are developed by propagating the uncertainties in neutron cross-section data to uncertainties in the computed responses for experiments and safety applications through sensitivity coefficients. The bias in the experiments, as a function of their correlation coefficient with the intended application, is extrapolated to predict the bias and bias uncertainty in the application through trending analysis or generalized linear least squares techniques, often referred to as 'data adjustment.' Even with advanced tools to identify benchmark experiments, analysts occasionally find that the application models include some feature or material for which adequately similar benchmark experiments do not exist to support validation. For example, a criticality safety analyst may want to take credit for the presence of fission products in spent nuclear fuel. In such cases, analysts sometimes rely on 'expert judgment' to select an additional administrative margin to account for gap in the validation data or to conclude that the impact on the calculated bias and bias uncertainty is negligible. As a result of advances in computer programs and the evolution of cross-section covariance data, analysts can use the sensitivity and uncertainty analysis tools in the TSUNAMI codes to estimate the potential impact on the application-specific bias and bias uncertainty resulting from nuclides not represented in available benchmark experiments. This paper presents the application of methods described in a companion paper.« less
Psychometric properties of EURO-D, a geriatric depression scale: a cross-cultural validation study.
Guerra, Mariella; Ferri, Cleusa; Llibre, Juan; Prina, A Matthew; Prince, Martin
2015-02-05
Many of the assessment tools used to study depression among older people are adaptations of instruments developed in other cultural setting. There is a need to validate those instruments in low and middle income countries (LMIC). A one-phase cross-sectional survey of people aged [greater than or equal to] 65 years from LMIC. EURO-D was checked for psychometric properties. Calibration with clinical diagnosis was made using ICD-10. Optimal cutpoint was determined. Concurrent validity was assessed measuring correlations with WHODAS 2.0. 17,852 interviews were completed in 13 sites from nine countries. EURO-D constituted a hierarchical scale in most sites. The most commonly endorsed symptom in Latin American sites was depression; in China was sleep disturbance and tearfulness; in India, irritability and fatigue and in Nigeria loss of enjoyment. Two factor structure (affective and motivation) were demonstrated. Measurement invariance was demonstrated among Latin American and Indian sites being less evident in China and Nigeria. At the 4/5 cutpoint, sensitivity for ICD-10 depressive episode was 86% or higher in all sites and specificity exceeded 84% in all Latin America and Chinese sites. Concurrent validity was supported, at least for Latin American and Indian sites. There is evidence for the cross-cultural validity of the EURO-D scale at Latin American and Indian settings and its potential applicability in comparative epidemiological studies.
San Alberto Giraldos, Mercedes; López Leiva, Inmaculada; León Campos, Álvaro; Martí García, Celia; García Mayor, Silvia
2018-01-01
Aims To adapt the Edinburgh Feeding Evaluation in Dementia Scale (EdFED) for use in a Spanish-speaking population and to assess its validity and reliability in patients with dementia. Method A cross-sectional study was carried out in two stages: 1. Cross-cultural adaptation (translation, back-translation, review by committee of experts, pilot test and weighting of results); 2. Clinimetric validation comprising interobserver reliability assessment, test-retest reliability and internal consistency. To determine construct validity, confirmatory factorial analysis and principal components analysis were performed by oblique rotations. Criteria validity was analysed using the Pearson correlation (p<0.05) with the BMI, MNA and analytical values of albumin, transferrin, cholesterol, absolute lymphocytes and total proteins. Data collection was carried out for six months in 2016 in nursing homes and Alzheimer’s day centers in the province of Málaga (Spain), at nine centers, with 262 patients (aged over 60 years and presenting feeding difficulties), 20 nurses, 20 professional caregivers and 103 family caregivers. Results A version of EdFED culturally adapted to Spanish was obtained. The sample presented the following characteristics: 76.3% women, mean age 82.3 years (SD: 7.9); MNA 18.73 (SD: 4.44); BMI 23.99 (SD: 4.72); serum albumin 3.79 mg/dl (SD: 0.36). A Cronbach’s alpha of 0.88 was obtained, with an inter-item global correlation of 0.43 and a homogeneity index ranging from 0.42 to 0.73. The exploratory factor analysis reproduced the three-factor model identified by the original authors, explaining 62.32% of the total variance. The criterion validity showed a good inverse correlation with MNA and a moderate one with albumin, total proteins, transferrin and BMI. Discussion The Spanish version of EdFED is reliable and valid for use in elderly people with dementia. The most appropriate for our environment is the three-factor model, which maintains the original factors, with a slight redistribution of the items. PMID:29486002
Kuzmanova, Rumyana; Stefanova, Irina; Velcheva, Irena; Stambolieva, Katerina
2014-10-01
Adverse effects (AEs) of antiepileptic drugs (AEDs) affect the quality of life of patients with epilepsy and their outcomes. There are no questionnaires or studies on the reliability and validity of instruments measuring AEs of AEDs in patients with epilepsy in Bulgarian language. The aim of the present study was the translation, cross-cultural adaptation, and validation of the LAEP in the Bulgarian language in order to use it in the Bulgarian-speaking population in providing a reliable instrument for the clinical monitoring of patients with epilepsy. One hundred thirty-one patients (57 men and 74 women, mean age: 40.13±13.37 years) took part in the investigation. The internal consistency and test-retest reliability were tested by Cronbach's α and ICC estimations. The convergent construct validity was tested by estimating the correlation of the LAEP-BG with the QOLIE-89 and the discriminant validity by evaluating the difference between LAEP-BG scores and clinical parameters such as the type of epilepsy using Kruskal-Wallis ANOVA. The LAEP-BG showed high internal consistency and reliability. The Cronbach's α of the total scale was 0.86. No significant differences between the Cronbach's α coefficients of the total LAEP-BG and original English, Chinese, Spanish, Korean, and Portuguese-Brazilian versions of the questionnaire were observed. The ICCs, which evaluate the test-retest reliability, were higher than the recommended value of 0.75 and determined the strong positive correlations between the first and second examinations. The creation of two subscales "Neurological and psychiatric side effects" and "Non neurological side effects" of the LAEP-BG proposed by us showed good internal consistency (Cronbach's α of 0.85 and 0.71, respectively). The LAEP-BG scores significantly correlated with other questionnaires such as the Quality of Life in Epilepsy Inventory-89 (QOLIE-89) and showed a good discriminative validity between groups with different levels of self-assessed AEs of AEDs. The Bulgarian version of the Liverpool Adverse Event Profile (LAEP) is a reliable and valid tool in assessing the patient-reported AEs of AEDs and their impact on the patient's outcome. Copyright © 2014 Elsevier Inc. All rights reserved.
Mohd Din, F H; Hoe, Victor C W; Chan, C K; Muslan, M A
2015-05-01
The Pain Catastrophizing Scale (PCS) is designed to assess negative thoughts in response to pain. It is composed of three domains: helplessness, rumination, and magnification. We report on the translation, adaptation, and validation of scores on a Malay-speaking version of the PCS, the PCS-MY. Guidelines for the process of cross-cultural adaptations of assessment measures were implemented. A sample of 303 young military recruits participated in the study. Factor structure, reliability, and validity of scores on the PCS-MY were examined. Convergent validity was investigated with the Positive and Negative Affect Scale, Short-form 12 version 2, and Ryff's Psychological Well-being Scale. Most participants were men, ranging in age from 19 to 26. The reliability of the PCS-MY scores was adequate (α = 0.90; mean inter-item correlation = 0.43). Confirmatory factor analysis showed that a modified version of the PCS-MY provided best fit estimates to the sample data. The PCS-MY total score was negatively correlated with mental well-being and positively correlated with negative affect (all ps < 0.001). The PCS-MY was demonstrated to have adequate reliability and validity estimates in the study sample.
Narin, Selnur; Unver, Bayram; Bakırhan, Serkan; Bozan, Ozgür; Karatosun, Vasfi
2014-01-01
The purpose of this study was to adapt the English version of the Hospital for Special Surgery (HSS) knee score for use in a Turkish population and to evaluate its validity, reliability and cultural adaptation. Standard forward-back translation of the HSS knee score was performed and the Turkish version was applied in 73 patients. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Mini-Mental State Examination and sit-to-stand test were also performed and analyzed. Internal consistency reliability was tested using Cronbach's alpha. The intraclass correlation coefficient (ICC) was used to calculate the test-retest reliability at one-week intervals. Validity was assessed by calculating the Pearson correlation between the HSS, WOMAC and sit-to-stand test scores. The ICC ranged from 0.98 to 0.99 with high internal consistency (Cronbach's alpha: 0.87). The WOMAC score correlated with total HSS score (r: -0.80, p<0.001) and sit-to-stand score (r: 0.12, p: 0.312). The Turkish version of the HSS knee score is reliable and valid in evaluating the total knee arthroplasty in Turkish patients.
Klebanov, Lev; Chen, Linlin; Yakovlev, Andrei
2007-11-07
This work was undertaken in response to a recently published paper by Okoniewski and Miller (BMC Bioinformatics 2006, 7: Article 276). The authors of that paper came to the conclusion that the process of multiple targeting in short oligonucleotide microarrays induces spurious correlations and this effect may deteriorate the inference on correlation coefficients. The design of their study and supporting simulations cast serious doubt upon the validity of this conclusion. The work by Okoniewski and Miller drove us to revisit the issue by means of experimentation with biological data and probabilistic modeling of cross-hybridization effects. We have identified two serious flaws in the study by Okoniewski and Miller: (1) The data used in their paper are not amenable to correlation analysis; (2) The proposed simulation model is inadequate for studying the effects of cross-hybridization. Using two other data sets, we have shown that removing multiply targeted probe sets does not lead to a shift in the histogram of sample correlation coefficients towards smaller values. A more realistic approach to mathematical modeling of cross-hybridization demonstrates that this process is by far more complex than the simplistic model considered by the authors. A diversity of correlation effects (such as the induction of positive or negative correlations) caused by cross-hybridization can be expected in theory but there are natural limitations on the ability to provide quantitative insights into such effects due to the fact that they are not directly observable. The proposed stochastic model is instrumental in studying general regularities in hybridization interaction between probe sets in microarray data. As the problem stands now, there is no compelling reason to believe that multiple targeting causes a large-scale effect on the correlation structure of Affymetrix gene expression data. Our analysis suggests that the observed long-range correlations in microarray data are of a biological nature rather than a technological flaw.
Panah, Sara Hojat; Baharlouie, Hamze; Rezaeian, Zahra Sadat; Hawker, Gilian
2016-01-01
The present study aimed to translate and evaluate the reliability and validity of the Persian version of the 11-item Intermittent and Constant Osteoarthritis Pain (ICOAP) measure in Iranian subjects with Knee Osteoarthritis (KOA). The ICOAP questionnaire was translated according to the Manufacturers Alliance for Productivity and Innovation (MAPI) protocol. The procedure consisted of forward and backward translation, as well as the assessment of the psychometric properties of the Persian version of the questionnaire. A sample of 230 subjects with KOA was asked to complete the Persian versions of ICOAP and Knee injury and Osteoarthritis Outcome Score (KOOS). The ICOAP was readministered to forty subjects five days after the first visit. Test-retest reliability was assessed using Intraclass Correlation Coefficient (ICC), and internal consistency was assessed by Cronbach's alpha and item-total correlation. The correlation between ICOAP and KOOS was determined using Spearman's correlation coefficient. Subjects found the Persian-version of the ICOAP to be clear, simple, and unambiguous, confirming its face validity. Spearman correlations between ICOAP total and subscale scores with KOOS scores were between 0.5 and 0.7, confirming construct validity. Cronbach's alpha, used to assess internal consistency, was 0.89, 0.93, and 0.92 for constant pain, intermittent pain, and total pain scores, respectively. The ICC was 0.90 for constant pain and 0.91 for the intermittent pain and total pain score. The Persian version of the ICOAP is a reliable and valid outcome measure that can be used in Iranian subjects with KOA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferraioli, Luigi; Hueller, Mauro; Vitale, Stefano
The scientific objectives of the LISA Technology Package experiment on board of the LISA Pathfinder mission demand accurate calibration and validation of the data analysis tools in advance of the mission launch. The level of confidence required in the mission outcomes can be reached only by intensively testing the tools on synthetically generated data. A flexible procedure allowing the generation of a cross-correlated stationary noise time series was set up. A multichannel time series with the desired cross-correlation behavior can be generated once a model for a multichannel cross-spectral matrix is provided. The core of the procedure comprises a noisemore » coloring, multichannel filter designed via a frequency-by-frequency eigendecomposition of the model cross-spectral matrix and a subsequent fit in the Z domain. The common problem of initial transients in a filtered time series is solved with a proper initialization of the filter recursion equations. The noise generator performance was tested in a two-dimensional case study of the closed-loop LISA Technology Package dynamics along the two principal degrees of freedom.« less
Kuo, Shu-Fen; Chang, Wen-Yin; Chang, Lu-I; Chou, Yu-Hua; Chen, Ching-Min
2013-01-01
This is a report of development and psychometric testing of the East Asian Acculturation Measure-Chinese version (EAAM-C) scale. An instrument validation design with a cross-sectional survey was conducted. The process was carried in two phases. In Phase 1, Barry's East Asian Acculturation Measure was translated and back translated to evaluate its content, face validity, and feasibility validity. In Phase 2, the 16-item EAAM-C was pilot-tested among 485 female immigrants for test-retest reliability, internal consistency, theoretically-supported construct validity and concurrent validity. The pilot work and the survey results indicated the tools possessed adequate content and face validity. The Cronbach's Alphas for the EAAM-C was 0.72, and 0.76-0.79 for its subscales, and the correlation of test-retest reliability (at 3 weeks) was 0.75. After dropping one item, four theoretically-supported factors which explained 61.82% of the variance were abstracted using exploratory factor analysis: assimilation, integration, separation, and marginalization. Based on the underlying four-factor theoretical structures of the EAAM, the confirmatory factor analysis of the EAAM-C was further examined. The analysis revealed that the four-factor model was an acceptable fit for the data which demonstrated adequate finding in its construct validity. These factors were inter-correlated, and showed statistically significant correlation with the Chinese Health Questionnaire, indicating adequate concurrent validity. The scale shows acceptable validity and consistency, and suggests that immigrant acculturation is a complex construct. This quick evaluation instrument can be applied to assess clients' acculturation and in further developing certain interventions to improve their health.
Rainfall Observed Over Bangladesh 2000-2008: A Comparison of Spatial Interpolation Methods
NASA Astrophysics Data System (ADS)
Pervez, M.; Henebry, G. M.
2010-12-01
In preparation for a hydrometeorological study of freshwater resources in the greater Ganges-Brahmaputra region, we compared the results of four methods of spatial interpolation applied to point measurements of daily rainfall over Bangladesh during a seven year period (2000-2008). Two univariate (inverse distance weighted and spline-regularized and tension) and two multivariate geostatistical (ordinary kriging and kriging with external drift) methods were used to interpolate daily observations from a network of 221 rain gauges across Bangladesh spanning an area of 143,000 sq km. Elevation and topographic index were used as the covariates in the geostatistical methods. The validity of the interpolated maps was analyzed through cross-validation. The quality of the methods was assessed through the Pearson and Spearman correlations and root mean square error measurements of accuracy in cross-validation. Preliminary results indicated that the univariate methods performed better than the geostatistical methods at daily scales, likely due to the relatively dense sampled point measurements and a weak correlation between the rainfall and covariates at daily scales in this region. Inverse distance weighted produced the better results than the spline. For the days with extreme or high rainfall—spatially and quantitatively—the correlation between observed and interpolated estimates appeared to be high (r2 ~ 0.6 RMSE ~ 10mm), although for low rainfall days the correlations were poor (r2 ~ 0.1 RMSE ~ 3mm). The performance quality of these methods was influenced by the density of the sample point measurements, the quantity of the observed rainfall along with spatial extent, and an appropriate search radius defining the neighboring points. Results indicated that interpolated rainfall estimates at daily scales may introduce uncertainties in the successive hydrometeorological analysis. Interpolations at 5-day, 10-day, 15-day, and monthly time scales are currently under investigation.
Cross-Cultural Adaptation and Validation of the Italian Version of SWAL-QOL.
Ginocchio, Daniela; Alfonsi, Enrico; Mozzanica, Francesco; Accornero, Anna Rosa; Bergonzoni, Antonella; Chiarello, Giulia; De Luca, Nicoletta; Farneti, Daniele; Marilia, Simonelli; Calcagno, Paola; Turroni, Valentina; Schindler, Antonio
2016-10-01
The aim of the study was to evaluate the reliability and validity of the Italian SWAL-QOL (I-SWAL-QOL). The study consisted of five phases: item generation, reliability analysis, normative data generation, validity analysis, and responsiveness analysis. The item generation phase followed the five-step, cross-cultural, adaptation process of translation and back-translation. A group of 92 dysphagic patients was enrolled for the internal consistency analysis. Seventy-eight patients completed the I-SWAL-QOL twice, 2 weeks apart, for test-retest reliability analysis. A group of 200 asymptomatic subjects completed the I-SWAL-QOL for normative data generation. I-SWAL-QOL scores obtained by both the group of dysphagic subjects and asymptomatic ones were compared for validity analysis. I-SWAL-QOL scores were correlated with SF-36 scores in 67 patients with dysphagia for concurrent validity analysis. Finally, I-SWAL-QOL scores obtained in a group of 30 dysphagic patients before and after successful rehabilitation treatment were compared for responsiveness analysis. All the enrolled patients managed to complete the I-SWAL-QOL without needing any assistance, within 20 min. Internal consistency was acceptable for all I-SWAL-QOL subscales (α > 0.70). Test-retest reliability was also satisfactory for all subscales (ICC > 0.7). A significant difference between the dysphagic group and the control group was found in all I-SWAL-QOL subscales (p < 0.05). Mild to moderate correlations between I-SWAL-QOL and SF-36 subscales were observed. I-SWAL-QOL scores obtained in the pre-treatment condition were significantly lower than those obtained after swallowing rehabilitation. I-SWAL-QOL is reliable, valid, responsive to changes in QOL, and recommended for clinical practice and outcome research.
Al-Hadethe, Ashraf; Hunt, Nigel; Thomas, Shirley; Al-Qaysi, Abdulgaffar
2016-02-01
The aim of this study was to translate and validate the psychometric properties of an Arabic Brief Religious Coping Scale. A descriptive correlational design was used to conduct the study among participants of 403 Iraqi secondary school students. The A-BRCS and both the subscales, positive and negative, had Cronbach's alphas of .70, .86 and .82, respectively. All inter-item and item-to-total correlations for each subscale were above the recommended criteria of .30. Factor loadings of the positive subscale using oblique (oblimin) and orthogonal (varimax) rotations ranged from .72 to .86 and from .71 to .86, respectively. Factor loadings of the negative subscale using oblimin and varimax rotations ranged from .64 to .83 and from .63 to .83, respectively. The A-BRCS was found to be a valid and reliable instrument to measure religious coping among Iraqi secondary school students.
The Multidimensional Loss Scale: validating a cross-cultural instrument for measuring loss.
Vromans, Lyn; Schweitzer, Robert D; Brough, Mark
2012-04-01
The Multidimensional Loss Scale (MLS) represents the first instrument designed specifically to index Experience of Loss Events and Loss Distress across multiple domains (cultural, social, material, and intrapersonal) relevant to refugee settlement. Recently settled Burmese adult refugees (N = 70) completed a questionnaire battery, including MLS items. Analyses explored MLS internal consistency, convergent and divergent validity, and factor structure. Cronbach alphas indicated satisfactory internal consistency for Experience of Loss Events (0.85) and Loss Distress (0.92), reflecting a unitary construct of multidimensional loss. Loss Distress did not correlate with depression or anxiety symptoms and correlated moderately with interpersonal grief and trauma symptoms, supporting divergent and convergent validity. Factor analysis provided preliminary support for a five-factor model: Loss of Symbolic Self, Loss of Interdependence, Loss of Home, Interpersonal Loss, and Loss of Intrapersonal Integrity. Received well by participants, the new scale shows promise for application in future research and practice.
Aloba, Olutayo; Olabisi, Oluseyi; Aloba, Tolulope
2016-01-01
The 10-item Connor-Davidson Resilience Scale (CD-RISC) has demonstrated satisfactory psychometric properties as a measure of resilience in all the previous studies conducted in developed countries. The objective of this study was to explore the psychometric characteristics of the 10-item CD-RISC among students nurses in southwestern Nigeria. This descriptive cross-sectional study involved a total of 449 student nurses who completed the 10-item CD-RISC in addition to measures of self-esteem, depression, religiosity, and psychological distress. The scale demonstrated adequate reliability (Cronbach's α = .81) and satisfactory validity with significant correlations with the measures of self-esteem, depression, religiosity, and psychological distress. Factor analyses revealed that resilience was best explained by a two-factor construct. The scale is a valid measure of resilience among Nigerian student nurses. © The Author(s) 2016.
Using smartphone technology to deliver a virtual pedestrian environment: usability and validation.
Schwebel, David C; Severson, Joan; He, Yefei
2017-09-01
Various programs effectively teach children to cross streets more safely, but all are labor- and cost-intensive. Recent developments in mobile phone technology offer opportunity to deliver virtual reality pedestrian environments to mobile smartphone platforms. Such an environment may offer a cost- and labor-effective strategy to teach children to cross streets safely. This study evaluated usability, feasibility, and validity of a smartphone-based virtual pedestrian environment. A total of 68 adults completed 12 virtual crossings within each of two virtual pedestrian environments, one delivered by smartphone and the other a semi-immersive kiosk virtual environment. Participants completed self-report measures of perceived realism and simulator sickness experienced in each virtual environment, plus self-reported demographic and personality characteristics. All participants followed system instructions and used the smartphone-based virtual environment without difficulty. No significant simulator sickness was reported or observed. Users rated the smartphone virtual environment as highly realistic. Convergent validity was detected, with many aspects of pedestrian behavior in the smartphone-based virtual environment matching behavior in the kiosk virtual environment. Anticipated correlations between personality and kiosk virtual reality pedestrian behavior emerged for the smartphone-based system. A smartphone-based virtual environment can be usable and valid. Future research should develop and evaluate such a training system.
Cacchio, Angelo; Necozione, Stefano; MacDermid, Joy C; Rompe, Jan Dirk; Maffulli, Nicola; di Orio, Ferdinando; Santilli, Valter; Paoloni, Marco
2012-08-01
The Patient-Rated Tennis Elbow Evaluation (PRTEE) questionnaire is a tool designed for self-assessment of forearm pain and disability in patients with lateral elbow tendinopathy (LET). However, an Italian version of this questionnaire has not been available. The aims of this study were: (1) to translate and cross-culturally adapt the PRTEE questionnaire into Italian and (2) to evaluate its measurement properties. This was a longitudinal, observational measurement study. The PRTEE questionnaire was cross-culturally adapted to Italian according to established guidelines. Ninety-five individuals (41 women, 54 men) with unilateral, imaging-confirmed, chronic LET were selected consecutively to assess the measurement properties of the PRTEE questionnaire. Internal consistency, test-retest reliability, construct validity, and responsiveness were estimated. The Italian version of the PRTEE displayed a high degree of internal consistency, with a Cronbach alpha of .95. The test-retest reliability was high for both short-term and medium-term, with intraclass correlation coefficients (2,1) of .95 and .93, respectively. The PRTEE exhibited a strong correlation (r=.77-.91, P<.0001) with the Disabilities of the Arm, Shoulder and Hand (DASH) at the baseline and a moderate correlation (r=.58-.74, P<.0001) at discharge. The responsiveness was higher for the PRTEE than for the DASH. Limitations A methodological limitation of the study is that due to the small sample size, a factor analysis was not performed to assess convergent validity. The Italian version of the PRTEE questionnaire is internally consistent, demonstrates expected correlations with other measures, and is more responsive than the DASH in Italian patients with chronic LET.
Wang, Lin; Hui, Stanley Sai-chuen; Wong, Stephen Heung-sang
2014-11-15
The current study aimed to examine the validity of various published bioelectrical impedance analysis (BIA) equations in estimating FFM among Chinese children and adolescents and to develop BIA equations for the estimation of fat-free mass (FFM) appropriate for Chinese children and adolescents. A total of 255 healthy Chinese children and adolescents aged 9 to 19 years old (127 males and 128 females) from Tianjin, China, participated in the BIA measurement at 50 kHz between the hand and the foot. The criterion measure of FFM was also employed using dual-energy X-ray absorptiometry (DEXA). FFM estimated from 24 published BIA equations was cross-validated against the criterion measure from DEXA. Multiple linear regression was conducted to examine alternative BIA equation for the studied population. FFM estimated from the 24 published BIA equations yielded high correlations with the directly measured FFM from DEXA. However, none of the 24 equations was statistically equivalent with the DEXA-measured FFM. Using multiple linear regression and cross-validation against DEXA measurement, an alternative prediction equation was determined as follows: FFM (kg)=1.613+0.742×height (cm)2/impedance (Ω)+0.151×body weight (kg); R2=0.95; SEE=2.45 kg; CV=6.5, 93.7% of the residuals of all the participants fell within the 95% limits of agreement. BIA was highly correlated with FFM in Chinese children and adolescents. When the new developed BIA equations are applied, BIA can provide a practical and valid measurement of body composition in Chinese children and adolescents.
Wang, Lin; Hui, Stanley Sai-chuen; Wong, Stephen Heung-sang
2014-01-01
Background The current study aimed to examine the validity of various published bioelectrical impedance analysis (BIA) equations in estimating FFM among Chinese children and adolescents and to develop BIA equations for the estimation of fat-free mass (FFM) appropriate for Chinese children and adolescents. Material/Methods A total of 255 healthy Chinese children and adolescents aged 9 to 19 years old (127 males and 128 females) from Tianjin, China, participated in the BIA measurement at 50 kHz between the hand and the foot. The criterion measure of FFM was also employed using dual-energy X-ray absorptiometry (DEXA). FFM estimated from 24 published BIA equations was cross-validated against the criterion measure from DEXA. Multiple linear regression was conducted to examine alternative BIA equation for the studied population. Results FFM estimated from the 24 published BIA equations yielded high correlations with the directly measured FFM from DEXA. However, none of the 24 equations was statistically equivalent with the DEXA-measured FFM. Using multiple linear regression and cross-validation against DEXA measurement, an alternative prediction equation was determined as follows: FFM (kg)=1.613+0.742×height (cm)2/impedance (Ω)+0.151×body weight (kg); R2=0.95; SEE=2.45kg; CV=6.5, 93.7% of the residuals of all the participants fell within the 95% limits of agreement. Conclusions BIA was highly correlated with FFM in Chinese children and adolescents. When the new developed BIA equations are applied, BIA can provide a practical and valid measurement of body composition in Chinese children and adolescents. PMID:25398209
Döpfner, Manfred; Steinhausen, Hans-Christoph; Coghill, David; Dalsgaard, Søren; Poole, Lynne; Ralston, Stephen J; Rothenberger, Aribert
2006-12-01
To provide psychometric information on the Attention-Deficit/Hyperactivity Disorder (ADHD) Rating Scale-IV (ADHD-RS-IV) in a large population of children with ADHD. Patients aged 6-18 years (n=1,478 in baseline analysis) were rated by 244 physicians on the ADHD-RS-IV based on a semi-structured interview with the patient's parent. Physicians additionally rated functional impairment (CGAS) and health status (CGI-S), and parents rated their child's behavioural and emotional problems (SDQ) and quality of life (CHIP-CE). Inattention and hyperactivity-impulsivity as dimensions of ADHD were replicated. 3-factor solutions reflecting the ICD-10 definition, with hyperactivity, impulsivity and inattention as separate dimensions were extracted in some national sub-samples and in separate analyses for boys and younger children.Good internal consistencies, strong country effects and small effects of age were found. Based on ADHD-RS-IV, 88.5% of patients met the criteria for any ADHD diagnosis. Correlations between ADHD-RS-IV and measures of functional impairment were low but statistically significant. The correlations with SDQ and CHIP-CE scales confirm the convergent and divergent validity of ADHD-RS-IV. Impressive evidence for the cross-cultural factorial validity, internal consistency as well as convergent and divergent validity of ADHD-RS-IV was found. ADHD can be assessed reliably and validly in routine care across Europe. The ICD-10 3-factor model seems to be less robust than the DSM-IV 2-factor model, but may be a good description for special populations (boys, younger children).
Are cross-cultural comparisons of norms on death anxiety valid?
Beshai, James A
2008-01-01
Cross-cultural comparisons of norms derived from research on Death Anxiety are valid as long as they provide existential validity. Existential validity is not empirically derived like construct validity. It is an understanding of being human unto death. It is the realization that death is imminent. It is the inner sense that provides a responder to death anxiety scales with a valid expression of his or her sense about the prospect of dying. It can be articulated in a life review by a disclosure of one's ontology. This article calls upon psychologists who develop death anxiety scales to disclose their presuppositions about death before administering a questionnaire. By disclosing his or her ontology a psychologist provides a means of disclosing his or her intentionality in responding to the items. This humanistic paradigm allows for an interactive participation between investigator and subject. Lester, Templer, and Abdel-Khalek (2006-2007) enriched psychology with significant empirical data on several correlates of death anxiety. But all scientists, especially psychologists, will always have alternative interpretations of the same empirical fact pattern. Empirical data is limited by the affirmation of the consequent limitation. A phenomenology of language and communication makes existential validity a necessary step for a broader understanding of the meaning of death anxiety.
Lohrer, Heinz; Nauck, Tanja
2009-10-30
Achilles tendinopathy is the predominant overuse injury in runners. To further investigate this overload injury in transverse and longitudinal studies a valid, responsive and reliable outcome measure is demanded. Most questionnaires have been developed for English-speaking populations. This is also true for the VISA-A score, so far representing the only valid, reliable, and disease specific questionnaire for Achilles tendinopathy. To internationally compare research results, to perform multinational studies or to exclude bias originating from subpopulations speaking different languages within one country an equivalent instrument is demanded in different languages. The aim of this study was therefore to cross-cultural adapt and validate the VISA-A questionnaire for German-speaking Achilles tendinopathy patients. According to the "guidelines for the process of cross-cultural adaptation of self-report measures" the VISA-A score was cross-culturally adapted into German (VISA-A-G) using six steps: Translation, synthesis, back translation, expert committee review, pretesting (n = 77), and appraisal of the adaptation process by an advisory committee determining the adequacy of the cross-cultural adaptation. The resulting VISA-A-G was then subjected to an analysis of reliability, validity, and internal consistency in 30 Achilles tendinopathy patients and 79 asymptomatic people. Concurrent validity was tested against a generic tendon grading system (Percy and Conochie) and against a classification system for the effect of pain on athletic performance (Curwin and Stanish). The "advisory committee" determined the VISA-A-G questionnaire as been translated "acceptable". The VISA-A-G questionnaire showed moderate to excellent test-retest reliability (ICC = 0.60 to 0.97). Concurrent validity showed good coherence when correlated with the grading system of Curwin and Stanish (rho = -0.95) and for the Percy and Conochie grade of severity (rho 0.95). Internal consistency (Cronbach's alpha) for the total VISA-A-G scores of the patients was calculated to be 0.737. The VISA-A questionnaire was successfully cross-cultural adapted and validated for use in German speaking populations. The psychometric properties of the VISA-A-G questionnaire are similar to those of the original English version. It therefore can be recommended as a sufficiently robust tool for future measuring clinical severity of Achilles tendinopathy in German speaking patients.
Lohrer, Heinz; Nauck, Tanja
2009-01-01
Background Achilles tendinopathy is the predominant overuse injury in runners. To further investigate this overload injury in transverse and longitudinal studies a valid, responsive and reliable outcome measure is demanded. Most questionnaires have been developed for English-speaking populations. This is also true for the VISA-A score, so far representing the only valid, reliable, and disease specific questionnaire for Achilles tendinopathy. To internationally compare research results, to perform multinational studies or to exclude bias originating from subpopulations speaking different languages within one country an equivalent instrument is demanded in different languages. The aim of this study was therefore to cross-cultural adapt and validate the VISA-A questionnaire for German-speaking Achilles tendinopathy patients. Methods According to the "guidelines for the process of cross-cultural adaptation of self-report measures" the VISA-A score was cross-culturally adapted into German (VISA-A-G) using six steps: Translation, synthesis, back translation, expert committee review, pretesting (n = 77), and appraisal of the adaptation process by an advisory committee determining the adequacy of the cross-cultural adaptation. The resulting VISA-A-G was then subjected to an analysis of reliability, validity, and internal consistency in 30 Achilles tendinopathy patients and 79 asymptomatic people. Concurrent validity was tested against a generic tendon grading system (Percy and Conochie) and against a classification system for the effect of pain on athletic performance (Curwin and Stanish). Results The "advisory committee" determined the VISA-A-G questionnaire as been translated "acceptable". The VISA-A-G questionnaire showed moderate to excellent test-retest reliability (ICC = 0.60 to 0.97). Concurrent validity showed good coherence when correlated with the grading system of Curwin and Stanish (rho = -0.95) and for the Percy and Conochie grade of severity (rho 0.95). Internal consistency (Cronbach's alpha) for the total VISA-A-G scores of the patients was calculated to be 0.737. Conclusion The VISA-A questionnaire was successfully cross-cultural adapted and validated for use in German speaking populations. The psychometric properties of the VISA-A-G questionnaire are similar to those of the original English version. It therefore can be recommended as a sufficiently robust tool for future measuring clinical severity of Achilles tendinopathy in German speaking patients. PMID:19878572
Single-station monitoring of volcanoes using seismic ambient noise
NASA Astrophysics Data System (ADS)
De Plaen, Raphael S. M.; Lecocq, Thomas; Caudron, Corentin; Ferrazzini, Valérie; Francis, Olivier
2016-08-01
Seismic ambient noise cross correlation is increasingly used to monitor volcanic activity. However, this method is usually limited to volcanoes equipped with large and dense networks of broadband stations. The single-station approach may provide a powerful and reliable alternative to the classical "cross-station" approach when measuring variation of seismic velocities. We implemented it on the Piton de la Fournaise in Reunion Island, a very active volcano with a remarkable multidisciplinary continuous monitoring. Over the past decade, this volcano has been increasingly studied using the traditional cross-correlation technique and therefore represents a unique laboratory to validate our approach. Our results, tested on stations located up to 3.5 km from the eruptive site, performed as well as the classical approach to detect the volcanic eruption in the 1-2 Hz frequency band. This opens new perspectives to successfully forecast volcanic activity at volcanoes equipped with a single three-component seismometer.
Liang, Yunyun; Liu, Sanyang; Zhang, Shengli
2016-12-01
Apoptosis, or programed cell death, plays a central role in the development and homeostasis of an organism. Obtaining information on subcellular location of apoptosis proteins is very helpful for understanding the apoptosis mechanism. The prediction of subcellular localization of an apoptosis protein is still a challenging task, and existing methods mainly based on protein primary sequences. In this paper, we introduce a new position-specific scoring matrix (PSSM)-based method by using detrended cross-correlation (DCCA) coefficient of non-overlapping windows. Then a 190-dimensional (190D) feature vector is constructed on two widely used datasets: CL317 and ZD98, and support vector machine is adopted as classifier. To evaluate the proposed method, objective and rigorous jackknife cross-validation tests are performed on the two datasets. The results show that our approach offers a novel and reliable PSSM-based tool for prediction of apoptosis protein subcellular localization. Copyright © 2016 Elsevier Inc. All rights reserved.
Bruscky, Dayanne Mota Veloso; Melo, Ana Caroline Cavalcanti Dela Bianca; Sarinho, Emanuel Sávio Cavalcanti
2017-01-01
To translate, adapt and validate the Itch Severity Scale to a Brazilian version (ISS-Ped) in order to measure the severity of pruritus in children and adolescents with atopic dermatitis. This is a methodological study of validation of an instrument following recommended protocols. The translated version was evaluated by a group of experts including one professional with experience in instrument validation, three English teachers, one linguistics teacher and seven allergists. After this, the scale was applied to 42 parents of children aged between 2 and 18 years old with atopic dermatitis, and 42 parents of children without pruritic diseases. Results were evaluated according to the severity of atopic dermatitis and disease control, and they were compared between groups with and without atopic dermatitis. More than 90% of the questions were clear to the parents. The ISS-Ped showed a strong positive correlation with the severity of atopic dermatitis (Pearson: 0.74; p<0.001) and a good correlation with the control of dermatitis (point-biserial correlation coefficient: 0.65; p<0.001). The scale showed excellent internal consistency (Cronbach's α: 0.96) and adequate test and retest agreement (95% confidence interval of intraclass correlation coefficient: 0.89-0.99; p<0.001). The ISS-Ped is a feasible, valid, reliable and satisfactorily equivalent. The translated scale was appropriate to assess the severity of itching in children and adolescents with eczema, allowing comparisons in the clinical practice and in the research setting.
Image correlation microscopy for uniform illumination.
Gaborski, T R; Sealander, M N; Ehrenberg, M; Waugh, R E; McGrath, J L
2010-01-01
Image cross-correlation microscopy is a technique that quantifies the motion of fluorescent features in an image by measuring the temporal autocorrelation function decay in a time-lapse image sequence. Image cross-correlation microscopy has traditionally employed laser-scanning microscopes because the technique emerged as an extension of laser-based fluorescence correlation spectroscopy. In this work, we show that image correlation can also be used to measure fluorescence dynamics in uniform illumination or wide-field imaging systems and we call our new approach uniform illumination image correlation microscopy. Wide-field microscopy is not only a simpler, less expensive imaging modality, but it offers the capability of greater temporal resolution over laser-scanning systems. In traditional laser-scanning image cross-correlation microscopy, lateral mobility is calculated from the temporal de-correlation of an image, where the characteristic length is the illuminating laser beam width. In wide-field microscopy, the diffusion length is defined by the feature size using the spatial autocorrelation function. Correlation function decay in time occurs as an object diffuses from its original position. We show that theoretical and simulated comparisons between Gaussian and uniform features indicate the temporal autocorrelation function depends strongly on particle size and not particle shape. In this report, we establish the relationships between the spatial autocorrelation function feature size, temporal autocorrelation function characteristic time and the diffusion coefficient for uniform illumination image correlation microscopy using analytical, Monte Carlo and experimental validation with particle tracking algorithms. Additionally, we demonstrate uniform illumination image correlation microscopy analysis of adhesion molecule domain aggregation and diffusion on the surface of human neutrophils.
Sharma, Mukesh C; Sharma, S
2016-12-01
A series of 2-dihydro-4-quinazolin with potent highly selective inhibitors of inducible nitric oxide synthase activities was subjected to quantitative structure activity relationships (QSAR) analysis. Statistically significant equations with high correlation coefficient (r 2 = 0.8219) were developed. The k-nearest neighbor model has showed good cross-validated correlation coefficient and external validation values of 0.7866 and 0.7133, respectively. The selected electrostatic field descriptors the presence of blue ball around R1 and R4 in the quinazolinamine moiety showed electronegative groups favorable for nitric oxide synthase activity. The QSAR models may lead to the structural requirements of inducible nitric oxide compounds and help in the design of new compounds.
Liu, Xuan; Ramella-Roman, Jessica C.; Huang, Yong; Guo, Yuan; Kang, Jin U.
2013-01-01
In this study, we proposed a generic speckle simulation for optical coherence tomography (OCT) signal, by convolving the point spread function (PSF) of the OCT system with the numerically synthesized random sample field. We validated our model and used the simulation method to study the statistical properties of cross-correlation coefficients (XCC) between Ascans which have been recently applied in transverse motion analysis by our group. The results of simulation show that over sampling is essential for accurate motion tracking; exponential decay of OCT signal leads to an under estimate of motion which can be corrected; lateral heterogeneity of sample leads to an over estimate of motion for a few pixels corresponding to the structural boundary. PMID:23456001
ERIC Educational Resources Information Center
Simonds, John F.; Simonds, M. Patricia
1982-01-01
Mothers of 182 nursery school children completed the Behavior Style Questionnaire (BSQ) and the Child Personality Scale (CPS). Intercorrelational analyses showed many significantly correlated items. Scores of the five CPS factors clearly distinguished between subjects in easy and difficult BSQ clusters. Found boys significantly more introverted…
Bifactor Approach to Modeling Multidimensionality of Physical Self-Perception Profile
ERIC Educational Resources Information Center
Chung, ChihMing; Liao, Xiaolan; Song, Hairong; Lee, Taehun
2016-01-01
The multi-dimensionality of Physical Self-Perception Profile (PSPP) has been acknowledged by the use of correlated-factor model and second-order model. In this study, the authors critically endorse the bifactor model, as a substitute to address the multi-dimensionality of PSPP. To cross-validate the models, analyses are conducted first in…
Wang, Wenyi; Kim, Marlene T.; Sedykh, Alexander
2015-01-01
Purpose Experimental Blood–Brain Barrier (BBB) permeability models for drug molecules are expensive and time-consuming. As alternative methods, several traditional Quantitative Structure-Activity Relationship (QSAR) models have been developed previously. In this study, we aimed to improve the predictivity of traditional QSAR BBB permeability models by employing relevant public bio-assay data in the modeling process. Methods We compiled a BBB permeability database consisting of 439 unique compounds from various resources. The database was split into a modeling set of 341 compounds and a validation set of 98 compounds. Consensus QSAR modeling workflow was employed on the modeling set to develop various QSAR models. A five-fold cross-validation approach was used to validate the developed models, and the resulting models were used to predict the external validation set compounds. Furthermore, we used previously published membrane transporter models to generate relevant transporter profiles for target compounds. The transporter profiles were used as additional biological descriptors to develop hybrid QSAR BBB models. Results The consensus QSAR models have R2=0.638 for fivefold cross-validation and R2=0.504 for external validation. The consensus model developed by pooling chemical and transporter descriptors showed better predictivity (R2=0.646 for five-fold cross-validation and R2=0.526 for external validation). Moreover, several external bio-assays that correlate with BBB permeability were identified using our automatic profiling tool. Conclusions The BBB permeability models developed in this study can be useful for early evaluation of new compounds (e.g., new drug candidates). The combination of chemical and biological descriptors shows a promising direction to improve the current traditional QSAR models. PMID:25862462
Validation of the Physical Activity Scale for individuals with physical disabilities.
van den Berg-Emons, Rita J; L'Ortye, Annemiek A; Buffart, Laurien M; Nieuwenhuijsen, Channah; Nooijen, Carla F; Bergen, Michael P; Stam, Henk J; Bussmann, Johannes B
2011-06-01
To determine the criterion validity of the Physical Activity Scale for Individuals With Physical Disabilities (PASIPD) by means of daily physical activity levels measured by using a validated accelerometry-based activity monitor in a large group of persons with a physical disability. Cross-sectional. Participants' home environment. Ambulatory and nonambulatory persons with cerebral palsy, meningomyelocele, or spinal cord injury (N=124). Not applicable. Self-reported physical activity level measured by using the PASIPD, a 2-day recall questionnaire, was correlated to objectively measured physical activity level measured by using a validated accelerometry-based activity monitor. Significant Spearman correlation coefficients between the PASIPD and activity monitor outcome measures ranged from .22 to .37. The PASIPD overestimated the duration of physical activity measured by using the activity monitor (mean ± SD, 3.9±2.9 vs 1.5±0.9h/d; P<.01). Significant correlation (ρ=-.74; P<.01) was found between average number of hours of physical activity per day measured by using the 2 methods and difference in hours between methods. This indicates larger overestimation for persons with higher activity levels. The PASIPD correlated poorly with objective measurements using an accelerometry-based activity monitor in people with a physical disability. However, similar low correlations between objective and subjective activity measurements have been found in the general population. Users of the PASIPD should be cautious about overestimating physical activity levels. Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Bouzubar, Fawzi F; Aljadi, Sameera H; Alotaibi, Naser M; Irrgang, James J
2018-07-01
The purpose of this study is to cross-culturally adapt the Knee Outcome Survey-Activities of Daily Living Scale into Arabic and to assess its psychometric properties (internal consistency, reliability, validity, and responsiveness) in patients with knee disorders. The cross-cultural adaptation process for the Knee Outcome Survey-Activities of Daily Living Scale into Arabic was performed consistent with the published guidelines. The psychometric properties of this Arabic version were then evaluated. Participants completed this version three times: at baseline, 2-4 days later, and 4 weeks later. Correlations between the Arabic version of Knee Outcome Survey-Activities of Daily Living Scale and the Arabic version of the Short Form-36 Health Survey, Get Up and Go, and Ascending/Descending stairs tests were evaluated. Linguistic and cultural issues were addressed. The Arabic version of the Knee Outcome Survey-Activities of Daily Living Scale demonstrated excellent internal consistency (Cronbach's alpha = 0.97) and excellent test-retest reliability (intraclass correlation coefficient = 0.97). Construct validity of the Arabic version of the Knee Outcome Survey-Activities of Daily Living Scale with the Arabic version of Short Form-36 Health Survey subscales ranged from r = 0.28 to 0.53, p < 0.001. Criterion validity with the Get Up and Go and Ascending/Descending stairs tests ranged from r = -0.47 to -0.60, p < 0.01. This Arabic version was able to detect changes 4 weeks later (effect size = 1.12 and minimum clinically important difference = 14 points). The Arabic version of the Knee Outcome Survey-Activities of Daily Living Scale is a reliable, valid and responsive measure for assessing knee-related symptoms and functional limitations Implications for rehabilitation The Knee Outcome Survey-Activities of Daily Living Scale-Arabic is a reliable, valid and responsive measure for assessing knee-related functional limitations. This Arabic version can be used in clinical practice and for research purposes to assess symptoms and functional limitations in Arabic-speaking patients with knee disorders. This scale is responsive to track therapeutic outcome of Arabic-speaking patients with knee disorders.
Çetin, Engin; Çelik, Evrim Coşkun; Acaroğlu, Emre; Berk, Haluk
2018-01-01
To produce a cross-culturally adapted and validated Turkish version of The Core Outcome Measure Index (COMI) Back questionnaire. Ninety-six Turkish-speaking patients with non-specific low back pain (LBP) were recruited from orthopedic and physical therapy outpatient clinics in a public hospital. They completed a booklet of questionnaires containing Turkish version of COMI, adjectival pain scale, Roland Morris disability questionnaire, European 5 Dimension Questionnaire and brief version of World Health Organization Quality of Life Questionnaire. Within following 7-14 days, 67 patients, reported no or minimal changes in their back pain status, completed the Turkish COMI again to assess reproducibility. Data quality was good with very few missing answers. COMI summary index score displayed 3% floor effects and no ceiling effects. The correlations between the COMI summary index score and each of the full instrument whole scores were found to be excellent to very good (ρ = - 0.81 to 0.74). Reliability expressed as intraclass correlation coefficient (ICC) was 0.95 (95% CI 0.91-0.97). Standard error of measurement (SEM agreement ) was acceptable at 0.41 and the minimum detectable change (MDC 95% ) was 1.14. Turkish version of the COMI has acceptable psychometric properties. It is a valid and reliable instrument and cross-culturally adapted, in accordance with established guidelines, for the use by Turkish-speaking patients. It can be recommended for use in evaluation of patients with chronic LBP in daily practice, in international multicenter studies and in spine registry systems.
NASA Astrophysics Data System (ADS)
Zhai, Mengting; Chen, Yan; Li, Jing; Zhou, Jun
2017-12-01
The molecular electrongativity distance vector (MEDV-13) was used to describe the molecular structure of benzyl ether diamidine derivatives in this paper, Based on MEDV-13, The three-parameter (M 3, M 15, M 47) QSAR model of insecticidal activity (pIC 50) for 60 benzyl ether diamidine derivatives was constructed by leaps-and-bounds regression (LBR) . The traditional correlation coefficient (R) and the cross-validation correlation coefficient (R CV ) were 0.975 and 0.971, respectively. The robustness of the regression model was validated by Jackknife method, the correlation coefficient R were between 0.971 and 0.983. Meanwhile, the independent variables in the model were tested to be no autocorrelation. The regression results indicate that the model has good robust and predictive capabilities. The research would provide theoretical guidance for the development of new generation of anti African trypanosomiasis drugs with efficiency and low toxicity.
Heo, K H; Squires, J; Yovanoff, P
2008-03-01
Accurate and efficient developmental screening measures are critical for early identification of developmental problems; however, few reliable and valid tests are available in Korea as well as other countries outside the USA. The Ages and Stages Questionnaires (ASQ) was chosen for study with young children in Korea. The ASQ was translated into Korean and necessary cross-cultural adaptations were made. The translated version was then distributed and completed by 3220 parents of young children between the ages of 4 months and 5 years. Reliability was studied including domain correlations, internal consistency, and performance of identification cut-off scores for the Korean population. Rasch analyses including tests of Differential Item Functioning, contrasting Korean and US samples were also performed. In general, internal consistency of the Korean ASQ was high, with overall correlations 0.75 for communication, 0.85 for gross motor, 0.74 for fine motor, 0.72 for problem solving, and 0.65 for personal-social. Validity, including concurrent validity, also had strong evidence. Mean scores of children on the Korean translation of the ASQ and the US normative sample were generally similar. Rasch analyses indicated the majority of items functioned similarly across the Korean sample. In general, the ASQ was translated with cultural appropriateness in mind and functioned as a valid and reliable parent-completed screening test to assist in early identification of young children with developmental delays. Further research is needed to confirm these results with a larger and more diverse Korean sample.
El-Housseiny, Azza A; Alsadat, Farah A; Alamoudi, Najlaa M; El Derwi, Douaa A; Farsi, Najat M; Attar, Moaz H; Andijani, Basil M
2016-04-14
Early recognition of dental fear is essential for the effective delivery of dental care. This study aimed to test the reliability and validity of the Arabic version of the Children's Fear Survey Schedule-Dental Subscale (CFSS-DS). A school-based sample of 1546 children was randomly recruited. The Arabic version of the CFSS-DS was completed by children during class time. The scale was tested for internal consistency and test-retest reliability. To test criterion validity, children's behavior was assessed using the Frankl scale during dental examination, and results were compared with children's CFSS-DS scores. To test the scale's construct validity, scores on "fear of going to the dentist soon" were correlated with CFSS-DS scores. Factor analysis was also used. The Arabic version of the CFSS-DS showed high reliability regarding both test-retest reliability (intraclass correlation = 0.83, p < 0.001) and internal consistency (Cronbach's α = 0.88). It showed good criterion validity: children with negative behavior had significantly higher fear scores (t = 13.67, p < 0.001). It also showed moderate construct validity (Spearman's rho correlation, r = 0.53, p < 0.001). Factor analysis identified the following factors: "fear of invasive dental procedures," "fear of less invasive dental procedures" and "fear of strangers." The Arabic version of the CFSS-DS is a reliable and valid measure of dental fear in Arabic-speaking children. Pediatric dentists and researchers may use this validated version of the CFSS-DS to measure dental fear in Arabic-speaking children.
The Arthroscopic Surgical Skill Evaluation Tool (ASSET).
Koehler, Ryan J; Amsdell, Simon; Arendt, Elizabeth A; Bisson, Leslie J; Braman, Jonathan P; Bramen, Jonathan P; Butler, Aaron; Cosgarea, Andrew J; Harner, Christopher D; Garrett, William E; Olson, Tyson; Warme, Winston J; Nicandri, Gregg T
2013-06-01
Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice; however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability when used to assess the technical ability of surgeons performing diagnostic knee arthroscopic surgery on cadaveric specimens. Cross-sectional study; Level of evidence, 3. Content validity was determined by a group of 7 experts using the Delphi method. Intra-articular performance of a right and left diagnostic knee arthroscopic procedure was recorded for 28 residents and 2 sports medicine fellowship-trained attending surgeons. Surgeon performance was assessed by 2 blinded raters using the ASSET. Concurrent criterion-oriented validity, interrater reliability, and test-retest reliability were evaluated. Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in the total ASSET score (P < .05) between novice, intermediate, and advanced experience groups were identified. Interrater reliability: The ASSET scores assigned by each rater were strongly correlated (r = 0.91, P < .01), and the intraclass correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: There was a significant correlation between ASSET scores for both procedures attempted by each surgeon (r = 0.79, P < .01). The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopic surgery in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live operating room and other simulated environments.
Evaluation of approaches for estimating the accuracy of genomic prediction in plant breeding
2013-01-01
Background In genomic prediction, an important measure of accuracy is the correlation between the predicted and the true breeding values. Direct computation of this quantity for real datasets is not possible, because the true breeding value is unknown. Instead, the correlation between the predicted breeding values and the observed phenotypic values, called predictive ability, is often computed. In order to indirectly estimate predictive accuracy, this latter correlation is usually divided by an estimate of the square root of heritability. In this study we use simulation to evaluate estimates of predictive accuracy for seven methods, four (1 to 4) of which use an estimate of heritability to divide predictive ability computed by cross-validation. Between them the seven methods cover balanced and unbalanced datasets as well as correlated and uncorrelated genotypes. We propose one new indirect method (4) and two direct methods (5 and 6) for estimating predictive accuracy and compare their performances and those of four other existing approaches (three indirect (1 to 3) and one direct (7)) with simulated true predictive accuracy as the benchmark and with each other. Results The size of the estimated genetic variance and hence heritability exerted the strongest influence on the variation in the estimated predictive accuracy. Increasing the number of genotypes considerably increases the time required to compute predictive accuracy by all the seven methods, most notably for the five methods that require cross-validation (Methods 1, 2, 3, 4 and 6). A new method that we propose (Method 5) and an existing method (Method 7) used in animal breeding programs were the fastest and gave the least biased, most precise and stable estimates of predictive accuracy. Of the methods that use cross-validation Methods 4 and 6 were often the best. Conclusions The estimated genetic variance and the number of genotypes had the greatest influence on predictive accuracy. Methods 5 and 7 were the fastest and produced the least biased, the most precise, robust and stable estimates of predictive accuracy. These properties argue for routinely using Methods 5 and 7 to assess predictive accuracy in genomic selection studies. PMID:24314298
Evaluation of approaches for estimating the accuracy of genomic prediction in plant breeding.
Ould Estaghvirou, Sidi Boubacar; Ogutu, Joseph O; Schulz-Streeck, Torben; Knaak, Carsten; Ouzunova, Milena; Gordillo, Andres; Piepho, Hans-Peter
2013-12-06
In genomic prediction, an important measure of accuracy is the correlation between the predicted and the true breeding values. Direct computation of this quantity for real datasets is not possible, because the true breeding value is unknown. Instead, the correlation between the predicted breeding values and the observed phenotypic values, called predictive ability, is often computed. In order to indirectly estimate predictive accuracy, this latter correlation is usually divided by an estimate of the square root of heritability. In this study we use simulation to evaluate estimates of predictive accuracy for seven methods, four (1 to 4) of which use an estimate of heritability to divide predictive ability computed by cross-validation. Between them the seven methods cover balanced and unbalanced datasets as well as correlated and uncorrelated genotypes. We propose one new indirect method (4) and two direct methods (5 and 6) for estimating predictive accuracy and compare their performances and those of four other existing approaches (three indirect (1 to 3) and one direct (7)) with simulated true predictive accuracy as the benchmark and with each other. The size of the estimated genetic variance and hence heritability exerted the strongest influence on the variation in the estimated predictive accuracy. Increasing the number of genotypes considerably increases the time required to compute predictive accuracy by all the seven methods, most notably for the five methods that require cross-validation (Methods 1, 2, 3, 4 and 6). A new method that we propose (Method 5) and an existing method (Method 7) used in animal breeding programs were the fastest and gave the least biased, most precise and stable estimates of predictive accuracy. Of the methods that use cross-validation Methods 4 and 6 were often the best. The estimated genetic variance and the number of genotypes had the greatest influence on predictive accuracy. Methods 5 and 7 were the fastest and produced the least biased, the most precise, robust and stable estimates of predictive accuracy. These properties argue for routinely using Methods 5 and 7 to assess predictive accuracy in genomic selection studies.
Li, Shun-Lai; He, Mao-Yu; Du, Hong-Guang
2011-01-01
The active metabolite of the novel immunosuppressive agent leflunomide has been shown to inhibit the enzyme dihydroorotate dehydrogenase (DHODH). This enzyme catalyzes the fourth step in de novo pyrimidine biosynthesis. Self-organizing molecular field analysis (SOMFA), a simple three-dimensional quantitative structure-activity relationship (3D-QSAR) method is used to study the correlation between the molecular properties and the biological activities of a series of analogues of the active metabolite. The statistical results, cross-validated rCV2 (0.664) and non cross-validated r2 (0.687), show a good predictive ability. The final SOMFA model provides a better understanding of DHODH inhibitor-enzyme interactions, and may be useful for further modification and improvement of inhibitors of this important enzyme. PMID:21686163
Validation and reliability of a Behcet's Syndrome Activity Scale in Korea.
Choi, Hyo Jin; Seo, Mi Ryoung; Ryu, Hee Jung; Baek, Han Joo
2016-01-01
We prepared a cross-cultural adaptation of the Behcet's Syndrome Activity Scale (BSAS) and evaluated its reliability and validity in Korea. Fifty patients with Behcet's disease (BD) who attended the Rheumatology Clinic of Gachon University Gil Medical Center were included in this study. The first BSAS questionnaire was administered at each clinic visit, and the second questionnaire was completed at home within 24 hours of the visit. A Behcet's Disease Current Activity Form (BDCAF) and a Behcet's Disease Quality of Life (BDQOL) form were also given to patients. The test-retest reliability was analyzed by intraclass correlation coefficients (ICC). To assess the validity, the total BSAS score was compared with the BDCAF score, the patient/physician global assessment, and the BDQOL by Spearman rank correlation. Twelve males and 38 females were enrolled. The mean age was 48.5 years and the mean disease duration was 6.7 years. Thirty-eight patients (76.0%) returned the questionnaire by mail. For the test-retest reliability, the two assessments were significantly correlated on all 10 items of the BSAS questionnaire (p < 0.05) and the total BSAS score (ICC, 0.925; p < 0.001). The total BSAS score was statistically correlated with the BDQOL, BDCAF, and patient/physician global assessment (p < 0.01). The Korean version of BSAS is a reliable and valid instrument to measure BD activity.
Processing methods for photoacoustic Doppler flowmetry with a clinical ultrasound scanner
NASA Astrophysics Data System (ADS)
Bücking, Thore M.; van den Berg, Pim J.; Balabani, Stavroula; Steenbergen, Wiendelt; Beard, Paul C.; Brunker, Joanna
2018-02-01
Photoacoustic flowmetry (PAF) based on time-domain cross correlation of photoacoustic signals is a promising technique for deep tissue measurement of blood flow velocity. Signal processing has previously been developed for single element transducers. Here, the processing methods for acoustic resolution PAF using a clinical ultrasound transducer array are developed and validated using a 64-element transducer array with a -6 dB detection band of 11 to 17 MHz. Measurements were performed on a flow phantom consisting of a tube (580 μm inner diameter) perfused with human blood flowing at physiological speeds ranging from 3 to 25 mm / s. The processing pipeline comprised: image reconstruction, filtering, displacement detection, and masking. High-pass filtering and background subtraction were found to be key preprocessing steps to enable accurate flow velocity estimates, which were calculated using a cross-correlation based method. In addition, the regions of interest in the calculated velocity maps were defined using a masking approach based on the amplitude of the cross-correlation functions. These developments enabled blood flow measurements using a transducer array, bringing PAF one step closer to clinical applicability.
Okereke, Olivia I; Copeland, Maura; Hyman, Bradley T; Wanggaard, Taylor; Albert, Marilyn S; Blacker, Deborah
2011-03-01
The Clinical Dementia Rating (CDR) and CDR Sum-of-Boxes can be used to grade mild but clinically important cognitive symptoms of Alzheimer disease. However, sensitive clinical interview formats are lengthy. To develop a brief instrument for obtaining CDR scores and to assess its reliability and cross-sectional validity. Using legacy data from expanded interviews conducted among 347 community-dwelling older adults in a longitudinal study, we identified 60 questions (from a possible 131) about cognitive functioning in daily life using clinical judgment, inter-item correlations, and principal components analysis. Items were selected in 1 cohort (n=147), and a computer algorithm for generating CDR scores was developed in this same cohort and re-run in a replication cohort (n=200) to evaluate how well the 60 items retained information from the original 131 items. Short interviews based on the 60 items were then administered to 50 consecutively recruited older individuals, with no symptoms or mild cognitive symptoms, at an Alzheimer's Disease Research Center. Clinical Dementia Rating scores based on short interviews were compared with those from independent long interviews. In the replication cohort, agreement between short and long CDR interviews ranged from κ=0.65 to 0.79, with κ=0.76 for Memory, κ=0.77 for global CDR, and intraclass correlation coefficient for CDR Sum-of-Boxes=0.89. In the cross-sectional validation, short interview scores were slightly lower than those from long interviews, but good agreement was observed for global CDR and Memory (κ≥0.70) as well as for CDR Sum-of-Boxes (intraclass correlation coefficient=0.73). The Structured Interview & Scoring Tool-Massachusetts Alzheimer's Disease Research Center is a brief, reliable, and sensitive instrument for obtaining CDR scores in persons with symptoms along the spectrum of mild cognitive change.
Akinpelu, Aderonke O; Odetunde, Marufat O; Odole, Adesola C
2012-12-01
Stroke-Specific Quality of Life 2.0 (SS-QoL 2.0) scale is used widely and has been cross-culturally adapted to many languages. This study aimed at the cross-cultural adaptation of SS-QoL 2.0 to Yoruba, the indigenous language of south-western Nigeria, and to carry out an initial investigation on its validity. English SS-QoL 2.0 was first adapted to Yoruba language by including Yoruba culture-specific examples in items SC4, UE2 and UE6. The adapted English version (AEV) was independently translated into Yoruba by two language experts who later agreed on a consensus translation, which was then back translated, subjected to an expert committee review and pretested; a cognitive debriefing interview was also carried out to generate the Yoruba translated version (YTV). Thirty-five stroke survivors completed the AEV and Yoruba version (YV) in English and Yoruba. The order of administration was randomized. Data were analysed using Spearman's rank order correlation and Wilcoxon's signed-rank test at a P value less than 0.05. The mean age of the participants (23 men, 12 women) was 58.5±11.3 years. The domain scores of the participants on AEV and YV did not differ significantly, except in the work/productivity domain. In both versions, the mean domain score of the participants was the highest in the language domain [22.6±3.8 (AEV) and 22.7±3.4 (YV)] and the lowest in the work domain [9.0±3.7 (AEV) and 8.0±3.3 (YTV)]. Domain scores on both versions correlated significantly (P<0.05). Participants' ratings of their current state and prestroke state correlated significantly (P<0.01) in all the general areas, except energy and mood. The YTV of SS-QoL 2.0 fulfilled the initial criteria for validity.
Ávila, Christiane Wahast; Riegel, Barbara; Pokorski, Simoni Chiarelli; Camey, Suzi; Silveira, Luana Claudia Jacoby; Rabelo-Silva, Eneida Rejane
2013-01-01
Objective. To adapt and evaluate the psychometric properties of the Brazilian version of the SCHFI v 6.2. Methods. With the approval of the original author, we conducted a complete cross-cultural adaptation of the instrument (translation, synthesis, back translation, synthesis of back translation, expert committee review, and pretesting). The adapted version was named Brazilian version of the self-care of heart failure index v 6.2. The psychometric properties assessed were face validity and content validity (by expert committee review), construct validity (convergent validity and confirmatory factor analysis), and reliability. Results. Face validity and content validity were indicative of semantic, idiomatic, experimental, and conceptual equivalence. Convergent validity was demonstrated by a significant though moderate correlation (r = −0.51) on comparison with equivalent question scores of the previously validated Brazilian European heart failure self-care behavior scale. Confirmatory factor analysis supported the original three-factor model as having the best fit, although similar results were obtained for inadequate fit indices. The reliability of the instrument, as expressed by Cronbach's alpha, was 0.40, 0.82, and 0.93 for the self-care maintenance, self-care management, and self-care confidence scales, respectively. Conclusion. The SCHFI v 6.2 was successfully adapted for use in Brazil. Nevertheless, further studies should be carried out to improve its psychometric properties. PMID:24163765
[Maslach Burnout Inventory - Student Survey: Portugal-Brazil cross-cultural adaptation].
Campos, Juliana Alvares Duarte Bonini; Maroco, João
2012-10-01
To perform a cross-cultural adaptation of the Portuguese version of the Maslach Burnout Inventory for students (MBI-SS), and investigate its reliability, validity and cross-cultural invariance. The face validity involved the participation of a multidisciplinary team. Content validity was performed. The Portuguese version was completed in 2009, on the internet, by 958 Brazilian and 556 Portuguese university students from the urban area. Confirmatory factor analysis was carried out using as fit indices: the χ²/df, the Comparative Fit Index (CFI), the Goodness of Fit Index (GFI) and the Root Mean Square Error of Approximation (RMSEA). To verify the stability of the factor solution according to the original English version, cross-validation was performed in 2/3 of the total sample and replicated in the remaining 1/3. Convergent validity was estimated by the average variance extracted and composite reliability. The discriminant validity was assessed, and the internal consistency was estimated by the Cronbach's alpha coefficient. Concurrent validity was estimated by the correlational analysis of the mean scores of the Portuguese version and the Copenhagen Burnout Inventory, and the divergent validity was compared to the Beck Depression Inventory. The invariance of the model between the Brazilian and the Portuguese samples was assessed. The three-factor model of Exhaustion, Disengagement and Efficacy showed good fit (c 2/df = 8.498, CFI = 0.916, GFI = 0.902, RMSEA = 0.086). The factor structure was stable (λ:χ²dif = 11.383, p = 0.50; Cov: χ²dif = 6.479, p = 0.372; Residues: χ²dif = 21.514, p = 0.121). Adequate convergent validity (VEM = 0.45;0.64, CC = 0.82;0.88), discriminant (ρ² = 0.06;0.33) and internal consistency (α = 0.83;0.88) were observed. The concurrent validity of the Portuguese version with the Copenhagen Inventory was adequate (r = 0.21, 0.74). The assessment of the divergent validity was impaired by the approach of the theoretical concept of the dimensions Exhaustion and Disengagement of the Portuguese version with the Beck Depression Inventory. Invariance of the instrument between the Brazilian and Portuguese samples was not observed (λ:χ²dif = 84.768, p<0.001; Cov: χ²dif = 129.206, p < 0.001; Residues: χ²dif = 518.760, p < 0.001). The Portuguese version of the Maslach Burnout Inventory for students showed adequate reliability and validity, but its factor structure was not invariant between the countries, indicating the absence of cross-cultural stability.
Naghdi, Soofia; Ansari, Noureddin Nakhostin; Raji, Parvin; Shamili, Aryan; Amini, Malek; Hasson, Scott
2016-01-01
To translate and cross-culturally adapt the Functional Independence Measure (FIM) into the Persian language and to test the reliability and validity of the Persian FIM (PFIM) in patients with stroke. In this cross-sectional study carried out in an outpatient stroke rehabilitation center, 40 patients with stroke (mean age 60 years) were participated. A standard forward-backward translation method and expert panel validation was followed to develop the PFIM. Two experienced occupational therapists (OTs) assessed the patients independently in all items of the PFIM in a single session for inter-rater reliability. One of the OTs reassessed the patients after 1 week for intra-rater reliability. There were no floor or ceiling effects for the PFIM. Excellent inter-rater and intra-rater reliability was noted for the PFIM total score, motor and cognitive subscales (ICC(agreement)0.88-0.98). According to the Bland-Altman agreement analysis, there was no systematic bias between raters and within raters. The internal consistency of the PFIM was with Cronbach's alpha from 0.70 to 0.96. The principal component analysis with varimax rotation indicated a three-factor structure: (1) self-care and mobility; (2) sphincter control and (3) cognitive that jointly accounted for 74.8% of the total variance. Construct validity was supported by a significant Pearson correlation between the PFIM and the Persian Barthel Index (r = 0.95; p < 0.001). The PFIM is a highly reliable and valid instrument for measuring functional status of Persian patients with stroke. The Functional Independence Measure (FIM) is an outcome measure for disability based on the International Classification of Functioning, Disability and Health (ICF). The FIM was cross-culturally adapted and validated into Persian language. The Persian version of the FIM (PFIM) is reliable and valid for assessing functional status of patients with stroke. The PFIM can be used in Persian speaking countries to assess the limitations in activities of daily living of patients with stroke.
Absorption in Sport: A Cross-Validation Study
Koehn, Stefan; Stavrou, Nektarios A. M.; Cogley, Jeremy; Morris, Tony; Mosek, Erez; Watt, Anthony P.
2017-01-01
Absorption has been identified as readiness for experiences of deep involvement in the task. Conceptually, absorption is a key psychological construct, incorporating experiential, cognitive, and motivational components. Although, no operationalization of the construct has been provided to facilitate research in this area, the purpose of this research was the development and examination of the psychometric properties of a sport-specific measure of absorption that evolved from the use of the modified Tellegen Absorption Scale (MODTAS; Jamieson, 2005) in mainstream psychology. The study aimed to provide evidence of the psychometric properties, reliability, and validity of the Measure of Absorption in Sport Contexts (MASCs). The psychometric examination included a calibration sample from Scotland and a cross-validation sample from Australia using a cross-sectional design. The item pool was developed based on existing items from the modified Tellegen Absorption Scale (Jamieson, 2005). The MODTAS items were reworded and translated into a sport context. The Scottish sample consisted of 292 participants and the Australian sample of 314 participants. Congeneric model testing and confirmatory factor analysis for both samples and multi-group invariance testing across samples was used. In the cross-validation sample the MASC subscales showed acceptable internal consistency and construct reliability (≥0.70). Excellent fit indices were found for the final 18-item, six-factor measure in the cross-validation sample, χ(120)2 = 197.486, p < 0.001; CFI = 0.957; TLI = 0.945; RMSEA = 0.045; SRMR = 0.044. Multi-group invariance testing revealed no differences in item meaning, except for two items. The MASC and the Dispositional Flow Scale-2 showed moderate-to-strong positive correlations in both samples, r = 0.38, p < 0.001 and r = 0.42, p < 0.001, supporting the external validity of the MASC. This article provides initial evidence in support of the psychometric properties, reliability, and validity of the sport-specific measure of absorption. The MASC provides rich research opportunities in sport psychology that can enhance the theoretical understanding between absorption and related constructs and facilitate future intervention studies. PMID:28883802
Estimation of Sensory Analysis Cupping Test Arabica Coffee Using NIR Spectroscopy
NASA Astrophysics Data System (ADS)
Safrizal; Sutrisno; Lilik, P. E. N.; Ahmad, U.; Samsudin
2018-05-01
Flavors have become the most important coffee quality parameters now day, many coffee consuming countries require certain taste scores for the coffee to be ordered, the currently used cupping method of appraisal is the method designed by The Specialty Coffee Association Of America (SCAA), from several previous studies was found that Near-Infrared Spectroscopy (NIRS) can be used to detect chemical composition of certain materials including those associated with flavor so it is possible also to be applied to coffee powder. The aim of this research is to get correlation between NIRS spectrum with cupping scoring by tester, then look at the possibility of testing coffee taste sensors using NIRS spectrum. The coffee samples were taken from various places, altitudes and postharvest handling methods, then the samples were prepared following the SCAA protocol, for sensory analysis was done in two ways, with the expert tester and with the NIRS test. The calibration between both found that Without pretreatment using PLS get RMSE cross validation 6.14, using Multiplicative Scatter Correction spectra obtained RMSE cross validation 5.43, the best RMSE cross-validation was 1.73 achieved by de-trending correction, NIRS can be used to predict the score of cupping.
Farokhnezhad Afshar, Pouya; Foroughan, Mahshid; Vedadhir, AbouAli; Ghazi Tabatabaie, Mahmood
2017-01-01
The Social Adaptation Self-evaluation Scale (SASS) is used to measure social function and social motivation in depressed patients. There is little attention to social function in the treatment of depression. The aim of this study was to assess the validity and reliability of the Persian version of SASS (P-SASS) for older adults. This is a cross-sectional and methodological study. The participants were 550 community-dwelling older adults living in Tehran who were selected randomly from the primary health care centers. To assess the psychometric properties of SASS, we first did translation and cross-cultural adjustment on SASS and then used P-SASS and the Geriatric Depression Scale (GDS) for gathering data. A number of analyses, including Pearson's correlation, exploratory factor analysis, and Cronbach's α , and receiver operating characteristic curve were used to manage the data with the IBM SPSS Statistics V.22. The mean age of the participants was 66.09±6.67 years, and 58.9% of them were male. The Cronbach's α was 0.97. The test-retest reliability correlation coefficient was 0.78. Principal component analysis showed that P-SASS consists of two components. P-SASS score showed a significant negative correlation with GDS ( r =-0.91, P <0.01), which suggests good convergent validity. The P-SASS cutoff point was 28 (sensitivity: 0.97 and specificity: 0.94). P-SASS has good reliability and validity for older adults. So, it can be considered as an appropriate tool to evaluate the social function and social motivation of older persons with and without depression.
Farazdaghi, Mohammad Reza; Mansoori, Ali; Vosoughi, Omid; Kordi Yoosefinejad, Amin
2017-05-01
Elbow joint pathologies are highly prevalent in Persian-speaking countries. A reliable low-cost method like an appropriate questionnaire is mandatory for the early diagnosis of elbow joint disorders. Among designed questionnaires, Patient-Rated Elbow Evaluation (PREE) is an accepted commonly used scale evaluating pain and dysfunction of the patients. The aims of the study were to cross-culturally adapt and also to identify the psychometric properties of the Persian PREE. The original version of the PREE was translated and cross-culturally adapted to Persian according to the guidelines by Beaton et al. Seventy-three patients and thirty-nine healthy people were enrolled in the study. Test-retest reliability and internal consistency were evaluated using ICC, Cronbach's alpha, and item-total correlation, respectively. Construct validity was investigated using Disability of Arm, Shoulder, and Hand (DASH) questionnaire and physical component scale of SF-36 (PCS). To determine a cutoff point for discriminating patients from non-patients, receiver operating characteristic curve was plotted. The Persian PREE displayed high internal consistency (Cronbach's alpha = 0.91) and had acceptable ICC values in the subscales and total score (ICC > 0.90). A positive moderate correlation with DASH (r = 0.66, P < 0.001) and a negative moderate correlation with PCS of SF-36 (r = -0.44, P < 0.001) were observed. The cutoff point equal to 13.16 was determined for Persian PREE. The Persian PREE exhibited promising validity and reliability. The findings supported its applicability in clinical situations that were consistent with the original version.
Adaptation and validation of the Diabetes Management Self-Efficacy Scale to Brazilian Portuguese 1
Pace, Ana Emilia; Gomes, Lilian Cristiane; Bertolin, Daniela Comelis; Loureiro, Helena Maria Almeira Macedo; Bijl, Jaap Van Der; Shortridge-Baggett, Lillie M.
2017-01-01
Objective: to perform the cultural adaptation and validation of the Diabetes Management Self-efficacy Scale for Patients with Type 2 Diabetes Mellitus with a Brazilian population sample. Method: cross-sectional methodological study in which the adaptation and validation process included the stages recommended in the literature. Construct validity and reliability were assessed with 200 adults with type 2 diabetes mellitus. Results: the items indicated by the panel of judges and by the target population were adjusted in the cultural adaptation to improve clarity and understanding. The instrument's four factors remained in the confirmatory factor analysis with factor loadings of items greater than 0.30, except for factor 4; convergent validity, verified by the multitrait-multimethod analysis, presented inter-item correlations from 0.37 to 0.92, while for discriminant validity, 100% of the items presented greater correlation in their own factors. Cronbach's coefficient alpha for the total scale was 0.78, ranging from 0.57 to 0.86 among factors. Conclusion: semantic, cultural, conceptual and idiomatic equivalences were achieved and the instrument's Brazilian version also presented psychometric properties that showed evidence of reliability and validity. Thus, it can be applied both in clinical practice and research. Self-efficacy is useful for planning and assessing educational interventions, as well as predicting behavior modification in self-care. PMID:28562700
Validation of virtual reality as a tool to understand and prevent child pedestrian injury.
Schwebel, David C; Gaines, Joanna; Severson, Joan
2008-07-01
In recent years, virtual reality has emerged as an innovative tool for health-related education and training. Among the many benefits of virtual reality is the opportunity for novice users to engage unsupervised in a safe environment when the real environment might be dangerous. Virtual environments are only useful for health-related research, however, if behavior in the virtual world validly matches behavior in the real world. This study was designed to test the validity of an immersive, interactive virtual pedestrian environment. A sample of 102 children and 74 adults was recruited to complete simulated road-crossings in both the virtual environment and the identical real environment. In both the child and adult samples, construct validity was demonstrated via significant correlations between behavior in the virtual and real worlds. Results also indicate construct validity through developmental differences in behavior; convergent validity by showing correlations between parent-reported child temperament and behavior in the virtual world; internal reliability of various measures of pedestrian safety in the virtual world; and face validity, as measured by users' self-reported perception of realism in the virtual world. We discuss issues of generalizability to other virtual environments, and the implications for application of virtual reality to understanding and preventing pediatric pedestrian injuries.
Xu, Xianghua; Liu, Xiangyu; Ou, Meijun; Xie, Chanjuan; Chen, Yongyi
2018-01-01
To translate the English work-related acceptance and action questionnaire (WAAQ), make cross-cultural adaptations, and examine its psychometric properties when used by Chinese oncology nurses. After translation, the psychometric properties of the Chinese WAAQ were analyzed among 417 nurses, and content validity was determined by six experts. Item-level content validity index (CVI) values were between 0.83 and 1.00; scale-level CVI/universal agreement (S-CVI/UA) and S-CVI/average were 0.86 and 0.98, respectively, which implicated a good content validity. The correlation of the Chinese WAAQ with AAQ-II ( r s = -0.247, P < 0.001) suggested criterion validity, and those with General Health Questionnaire-12 (-0.250, <0.001) and general self-efficacy scale (0.491, <0.001) and Utrecht work engagement scale (UWES) (0.439, <0.001) suggested convergent validity. Exploratory factor analysis identified a seven-item, one-factor structure of WAAQ. The Chinese version of WAAQ had high internal consistency (Cronbach's α = 0.920), with an item-total correlation coefficient of 0.702-0.828 ( P < 0.05), split-half reliability of 0.933, and test-retest reliability of 0.772. The Chinese WAAQ is a reliable and valid tool for assessing psychological flexibility in Chinese oncology nurses.
Shrestha, Bidhan; Niraula, Surya Raj; Parajuli, Prakash K; Suwal, Pramita; Singh, Raj Kumar
2018-06-01
To assess the reliability and to validate the translated Nepalese version of the Oral Health Impact Profile (OHIP-EDENT-N) in Nepalese edentulous subjects. The international guidelines for translation and cross-cultural adaption of OHIP-EDENT were followed, and a Nepalese version of the questionnaire was adapted for this study. Eighty-eight completely edentulous subjects were then selected for the study and completed their responses for the questionnaire. The reliability of the OHIP-EDENT-N was evaluated using internal consistency. Validity was assessed as construct and convergent validity. Construct validity was determined using exploratory factor analysis (EFA). The correlation between OHIP-EDENT-N subscale scores and the global question was investigated to test the convergent validity. Cronbach's alpha for the total score of OHIP-EDENT-N was 0.78. Construct validity was assessed by factor analysis: 70.196% of the variance was accountable to five factors extracted from the factor analysis. Factor loadings above 0.40 were noted for all items. In terms of convergent validity, significant correlations could be established between OHIP-EDENT-N and global questions. This study has been able to establish the reliability and validity of the OHIP-EDENT-N, and OHIP-EDENT-N can be a considered a reliable tool to assess the oral health related quality of life in the Nepalese edentulous population. © 2016 by the American College of Prosthodontists.
NASA Astrophysics Data System (ADS)
Raymond Ooi, C. H.; Sun, Qingqing; Zubairy, M. Suhail; Scully, Marlan O.
2007-01-01
We present a largely analytical theory for two-photon correlations G(2) between Stokes (s) and anti-Stokes (a) photon pairs from an extended medium (amplifier) composed of double- Λ atoms in counterpropagating geometry. We generalize the parametric coupled equations with quantum Langevin noise given in a beautiful experimental paper of Balic [Phys. Rev. Lett. 94, 183601 (2005)] beyond adiabatic approximation and valid for arbitrary strength and detuning of laser fields. We derive an analytical formula for cross correlation Gas(2)=⟨Ês†(L)Êa†(0,τ)Êa(0,τ)Ês(L)⟩ and use it to obtain results that are in good quantitative agreement with the experimental data. Results for Gas(2) obtained using our coupled equations are in good quantitative agreement with the results using the equations of Balic , while perfect agreement is obtained for sufficiently large detuning. We also compute the reverse correlation Gsa(2) which turns out to be negligibly small and remains classical while the cross correlation violates the Cauchy-Schwartz inequality by a factor of more than a hundred.
Arimura, Tatsuyuki; Hosoi, Masako; Tsukiyama, Yoshihiro; Yoshida, Toshiyuki; Fujiwara, Daiki; Tanaka, Masanori; Tamura, Ryuichi; Nakashima, Yasunori; Sudo, Nobuyuki; Kubo, Chiharu
2012-04-01
The present study aimed to develop a Japanese version of the Short-Form McGill Pain Questionnaire (SF-MPQ-J) that focuses on cross-culturally equivalence to the original English version and to test its reliability and validity. Cross-sectional design. In study 1, SF-MPQ was translated and adapted into Japanese. It included construction of response scales equivalent to the original using a variation of the Thurstone method of equal-appearing intervals. A total of 147 undergraduate students and 44 pain patients participated in the development of the Japanese response scales. To measure the equivalence of pain descriptors, 62 pain patients in four diagnostic groups were asked to choose pain descriptors that described their pain. In study 2, chronic pain patients (N=126) completed the SF-MPQ-J, the Long-Form McGill Pain Questionnaire Japanese version (LF-MPQ-J), and the 11-point numerical rating scale of pain intensity. Correlation analysis examined the construct validity of the SF-MPQ-J. The results from study 1 were used to develop SF-MPQ-J, which is linguistically equivalent to the original questionnaire. Response scales from SF-MPQ-J represented the original scale values. All pain descriptors, except one, were used by >33% in at least one of the four diagnostic groups. Study 2 exhibited adequate internal consistency and test-retest reliability, with the construct validity of SF-MPQ-J comparable to the original. These findings suggested that SF-MPQ-J is reliable, valid, and cross-culturally equivalent to the original questionnaire. Researchers might consider using this scale in multicenter, multi-ethnical trials or cross-cultural studies that include Japanese-speaking patients. Wiley Periodicals, Inc.
Hall, Emily A; Docherty, Carrie L
2017-07-01
To determine the concurrent validity of standard clinical outcome measures compared to laboratory outcome measure while performing the weight-bearing lunge test (WBLT). Cross-sectional study. Fifty participants performed the WBLT to determine dorsiflexion ROM using four different measurement techniques: dorsiflexion angle with digital inclinometer at 15cm distal to the tibial tuberosity (°), dorsiflexion angle with inclinometer at tibial tuberosity (°), maximum lunge distance (cm), and dorsiflexion angle using a 2D motion capture system (°). Outcome measures were recorded concurrently during each trial. To establish concurrent validity, Pearson product-moment correlation coefficients (r) were conducted, comparing each dependent variable to the 2D motion capture analysis (identified as the reference standard). A higher correlation indicates strong concurrent validity. There was a high correlation between each measurement technique and the reference standard. Specifically the correlation between the inclinometer placement at 15cm below the tibial tuberosity (44.9°±5.5°) and the motion capture angle (27.0°±6.0°) was r=0.76 (p=0.001), between the inclinometer placement at the tibial tuberosity angle (39.0°±4.6°) and the motion capture angle was r=0.71 (p=0.001), and between the distance from the wall clinical measure (10.3±3.0cm) to the motion capture angle was r=0.74 (p=0.001). This study determined that the clinical measures used during the WBLT have a high correlation with the reference standard for assessing dorsiflexion range of motion. Therefore, obtaining maximum lunge distance and inclinometer angles are both valid assessments during the weight-bearing lunge test. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Nair, Rahul; Tsakos, Georgios; Yee Ting Fai, Robert
2016-12-01
To cross-culturally adapt the oral impacts on daily performance (OIDP) and assess its reliability and validity on Chinese-speaking community dwelling elderly Singaporeans. There are no previous reports of valid oral health-related quality of life instruments for elderly Singaporeans or perceived conditions associated with impacts reported in OIDP among the Singaporean elders. The OIDP was translated from English to Chinese and then back translated. The OIDP questionnaire along with questions related to overall quality of life and self-rated dental health was administered to 202 Chinese-speaking elderly Singaporeans by trained interviewers, and it was repeated after 1 month. Test-retest reliability was assessed using intraclass correlation coefficient; internal consistency was established using Cronbach's alpha, and construct validity using correlation coefficients with self-reported oral health-related and global quality of life measures. In addition, Kruskal-Wallis tests assessed differences in the OIDP score between different subjective health and global quality of life groups. The median age of participants was 75 years. About 19% reported oral impacts and difficulty eating was the most prevalent oral impact. Internal consistency was good with a Cronbach's alpha of 0.75, and the intraclass correlation coefficient was 0.75 (0.67-0.81). OIDP was significantly correlated with all measures of self-reported oral health and global ratings of quality of life, with correlation coefficients ranging between 0.15 and 0.52. Groups with worse perceptions about their health and quality of life had significantly higher OIDP scores. The OIDP showed successful reliability and validity for its use among Chinese-speaking older Singaporeans. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.
Luo, Nan; Low, Serena; Lau, Puay-Ngoh; Au, Wing-Lok; Tan, Louis C S
2009-06-01
The purpose of the present study was to evaluate the validity of the EQ-5D in patients with Parkinson's disease (PD) in Singapore. In a cross-sectional survey, patients with PD completed English or Chinese version of the EQ-5D, the 8-item Parkinson's disease questionnaire (PDQ-8), and questions assessing socio-demographic and health characteristics. Clinical data were retrieved from patients' medical records. The validity of the EQ-5D was assessed by testing a-priori hypotheses relating the EQ-5D to the PDQ-8 and clinical data. Two hundred and eight PD patients (English speaking: 135) participated in the study. Spearman correlation coefficients between the EQ-5D and PDQ-8 ranged from 0.25 to 0.75 for English-speaking patients and from 0.16 to 0.67 for Chinese-speaking patients. By and large, the EQ-5D scores were weakly or moderately correlated with Hoehn and Yahr stage (correlation coefficients: 0.05 to 0.43), Schwab and England Activities of Daily Living score (correlation coefficients: 0.10 to 0.60), and duration of PD (correlation coefficients: 0.16 to 0.43). The EQ-5D index scores for patients with dyskinesia or "wearing off" periods were significantly lower than those without these problems. The EQ-5D Visual Analog Scale (EQ-VAS) scores also differed for English-speaking patients with deferring dyskinesia, "wearing off" periods, or health transition status; however, such differences were not observed in patients who completed the survey in Chinese. The EQ-5D questionnaire appears valid for measuring quality of life in patients with PD in Singapore. However, the validity of EQ-VAS in Chinese-speaking patients with PD should be further assessed.
Beaudart, Charlotte; Edwards, Mark; Moss, Charlotte; Reginster, Jean-Yves; Moon, Rebecca; Parsons, Camille; Demoulin, Christophe; Rizzoli, René; Biver, Emmanuel; Dennison, Elaine; Bruyere, Olivier; Cooper, Cyrus
2017-03-01
the first quality of life questionnaire specific to sarcopenia, the SarQoL®, has recently been developed and validated in French. To extend the availability and utilisation of this questionnaire, its translation and validation in other languages is necessary. the purpose of this study was therefore to translate the SarQoL® into English and validate the psychometric properties of this new version. cross-sectional. Hertfordshire, UK. in total, 404 participants of the Hertfordshire Cohort Study, UK. the translation part was articulated in five stages: (i) two initial translations from French to English; (ii) synthesis of the two translations; (iii) backward translations; (iv) expert committee to compare the backward translations with the original questionnaire and (v) pre-test. To validate the English SarQoL®, we assessed its validity (discriminative power, construct validity), reliability (internal consistency, test-retest reliability) and floor/ceiling effects. the SarQoL® questionnaire was translated without any major difficulties. Results indicated a good discriminative power (lower score of quality of life for sarcopenic subjects, P = 0.01), high internal consistency (Cronbach's alpha of 0.88), consistent construct validity (high correlations found with domains related to mobility, usual activities, vitality, physical function and low correlations with domains related to anxiety, self-care, mental health and social problems) and excellent test-retest reliability (intraclass coefficient correlation of 0.95, 95%CI 0.92-0.97). Moreover, no floor/ceiling has been found. a valid SarQoL® English questionnaire is now available and can be used with confidence to better assess the disease burden associated with sarcopenia. It could also be used as a treatment outcome indicator in research. © The Author 2016. Published by Oxford University Press on behalf of the British Geriatrics Society.
Mouratidou, Theodora; Ford, Fiona A; Fraser, Robert B
2011-04-01
The aim of this study was to examine the reproducibility and validity of a semi-quantitative food frequency questionnaire (FFQ) for assessing dietary intakes of low-income, Caucasian, English-speaking, postpartum women living in Sheffield, United Kingdom. Data was obtained from a cross-sectional sample of the 'Healthy Start' study; a population-based survey of mothers and infants. Participants completed two FFQs at 4 and 8 weeks postpartum. Measures from 24-hour dietary recalls (24HDRs) were collected at 4, 6, 8 and 12 weeks postpartum. In the reproducibility study, crude Pearson's correlation coefficients ranged from 0.40 (riboflavin) to 0.73 (thiamine), mean value 0.54. In the validation study, crude Pearson correlation coefficients between the FFQ and the measures from the 24HDRs ranged from 0.10 (B12) to 0.55 (manganese), mean value 0.34. Energy-adjustments and corrections for attenuation had no significant effect on the strength of the correlation both observed in the reproducibility and validity study. On average, 68% of the participants were classified correctly, and 3% were misclassified into the extreme opposite quintile of the distribution. The authors conclude that the questionnaire performed well for the majority of nutrients examined and that is a valid tool for ranking individuals according to nutrient distribution. © 2009 Blackwell Publishing Ltd.
Öksüz, Çigdem; Alemdaroglu, Ipek; Kilinç, Muhammed; Abaoğlu, Hatice; Demirci, Cevher; Karahan, Sevilay; Yilmaz, Oznur; Yildirim, Sibel Aksu
2017-10-01
This study was performed to examine the reliability and validity of the Turkish version of ABILHAND-Kids questionnaire which assesses manual functions of children with neuromuscular diseases (NMDs). A cross sectional survey study design and Rasch analysis were used to assess the reliability and validity of the Turkish version of scale. Ninety-three children with different neuromuscular disorders and their parents were included in the study. The scale was applied to the parents with face-to-face interview twice; on their first visit and after an interval of 15 days. The test-retest reliability was assessed with intraclass correlation coefficient (ICC), and internal consistency of the multi-item subscales by calculating Cronbach alpha values. Brooke Upper Extremity Functional Classification (BUEFC) and Wee-Functional Independency Measurement (Wee-FIM) were correlated to determine the construct validity. The ICC value for the test/retest reliability was 0.94. The internal consistency was 0.81. Floor (1.1%) and ceiling (11.8%) effects were not significant. There were moderate correlations between the Turkish version of ABILHAND-Kids and Wee-FIM (0.67) and BUEFC (-0.37). Rasch analysis indicated good item fit, unidimensionality, and model fit. The Turkish version of ABILHAND-Kids questionnaire was found to be a reliable and valid scale for the assessment of the manual ability of children with NMDs.
Ridao-Fernández, Carmen; Ojeda, Joaquín; Benítez-Lugo, Marisa; Sevillano, José Luis
2016-01-01
Objective The aim of this study was to design and validate a functional assessment scale for assisted gait with forearm crutches (Chamorro Assisted Gait Scale—CHAGS) and to assess its reliability in people with sprained ankles. Design Thirty subjects who suffered from sprained ankle (anterior talofibular ligament first and second degree) were included in the study. A modified Delphi technique was used to obtain the content validity. The selected items were: pelvic and scapular girdle dissociation(1), deviation of Center of Gravity(2), crutch inclination(3), steps rhythm(4), symmetry of step length(5), cross support(6), simultaneous support of foot and crutch(7), forearm off(8), facing forward(9) and fluency(10). Two raters twice visualized the gait of the sample subjects which were recorded. The criterion-related validity was determined by correlation between CHAGS and Coding of eight criteria of qualitative gait analysis (Viel Coding). Internal consistency and inter and intra-rater reliability were also tested. Results CHAGS obtained a high and negative correlation with Viel Coding. We obtained a good internal consistency and the intra-class correlation coefficients oscillated between 0.97 and 0.99, while the minimal detectable changes were acceptable. Conclusion CHAGS scale is a valid and reliable tool for assessing assisted gait with crutches in people with sprained ankles to perform partial relief of lower limbs. PMID:27168236
Jans, Marielle P; Slootweg, Vera C; Boot, Cecile R; de Morton, Natalie A; van der Sluis, Geert; van Meeteren, Nico L
2011-11-01
To examine the reproducibility, construct validity, and unidimensionality of the Dutch translation of the de Morton Mobility Index (DEMMI), a performance-based measure of mobility for older patients. Cross-sectional study. Rehabilitation center (reproducibility study) and hospital (validity study). Patients (N=28; age >65y) after orthopedic surgery (reproducibility study) and patients (N=219; age >65y) waiting for total hip or total knee arthroplasty (validity study). Not applicable. Not applicable. The intraclass correlation coefficient for interrater reliability was high (.85; 95% confidence interval, 71-.93), and minimal detectable change with 90% confidence was 7 on the 100-point DEMMI scale. Rasch analysis identified that the Dutch translation of the DEMMI is a unidimensional measure of mobility in this population. DEMMI scores showed high correlations with scores on other performance-based measures of mobility (Timed Up and Go test, Spearman r=-.73; Chair Rise Time, r=-.69; walking test, r=.74). A lower correlation of .44 was identified with the self-report measure Western Ontario and McMaster Universities Osteoarthritis Index. The Dutch translation of the DEMMI is a reproducible and valid performance-based measure for assessing mobility in older patients with knee or hip osteoarthritis. Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Uchoa, Priscila Regina Candido Espinola; Bezerra, Thiago Freire Pinto; Lima, Élcio Duarte; Fornazieri, Marco Aurélio; Pinna, Fabio de Rezende; Sperandio, Fabiana de Araújo; Voegels, Richard Louis
The concept of quality of life is subjective and variable definition, which depends on the individual's perception of their state of health. Quality of life questionnaires are instruments designed to measure quality of life, but most are developed in a language other than Portuguese. Questionnaires can identify the most important symptoms, focus on consultation, and assist in defining the goals of treatment. Some of these have been validated for the Portuguese language, but none in children. To validate the translation with cross-cultural adaptation and validation of the Sinus and Nasal Quality of Life Survey (SN-5) into Portuguese. Prospective study of children aged 2-12 years with sinonasal symptoms of over 30 days. The study comprised two stages: (I) translation and cross-cultural adaptation of the SN-5 into Portuguese (SN-5p); and (II) validation of the SN5-p. Statistical analysis was performed to assess internal consistency, test-retest reliability, and sensitivity, as well as construct and discriminant validity and standardization. The SN-5 was translated and adapted into Portuguese (SN-5p) and the author of the original version approved the process. Validation was carried out by administration of the SN-5p to 51 pediatric patients with sinonasal complaints (mean age, 5.8±2.5 years; range, 2-12 years). The questionnaire exhibited adequate construct validity (0.62, p<0.01), internal consistency (Cronbach's alpha=0.73), and discriminant validity (p<0.01), as well as good test-retest reproducibility (Goodman-Kruskal gamma=0.957, p<0.001), good correlation with a visual analog scale (r=0.62, p<0.01), and sensitivity to change. This study reports the successful translation and cross-cultural adaptation of the SN-5 instrument into Brazilian Portuguese. The translated version exhibited adequate psychometric properties for assessment of disease-specific quality of life in pediatric patients with sinonasal complaints. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Prediction of functional aerobic capacity without exercise testing
NASA Technical Reports Server (NTRS)
Jackson, A. S.; Blair, S. N.; Mahar, M. T.; Wier, L. T.; Ross, R. M.; Stuteville, J. E.
1990-01-01
The purpose of this study was to develop functional aerobic capacity prediction models without using exercise tests (N-Ex) and to compare the accuracy with Astrand single-stage submaximal prediction methods. The data of 2,009 subjects (9.7% female) were randomly divided into validation (N = 1,543) and cross-validation (N = 466) samples. The validation sample was used to develop two N-Ex models to estimate VO2peak. Gender, age, body composition, and self-report activity were used to develop two N-Ex prediction models. One model estimated percent fat from skinfolds (N-Ex %fat) and the other used body mass index (N-Ex BMI) to represent body composition. The multiple correlations for the developed models were R = 0.81 (SE = 5.3 ml.kg-1.min-1) and R = 0.78 (SE = 5.6 ml.kg-1.min-1). This accuracy was confirmed when applied to the cross-validation sample. The N-Ex models were more accurate than what was obtained from VO2peak estimated from the Astrand prediction models. The SEs of the Astrand models ranged from 5.5-9.7 ml.kg-1.min-1. The N-Ex models were cross-validated on 59 men on hypertensive medication and 71 men who were found to have a positive exercise ECG. The SEs of the N-Ex models ranged from 4.6-5.4 ml.kg-1.min-1 with these subjects.(ABSTRACT TRUNCATED AT 250 WORDS).
Kim, Myoung-Hee; Cho, Young-Shin; Uhm, Wan-Sik; Kim, Sehyun; Bae, Sang-Cheol
2005-06-01
This study aimed to determine the cross-cultural adaptation and validation of the Korean version of the EQ-5D in rheumatic conditions. Translation, back-translation and cognitive debriefing were performed according to the EuroQol group's guidelines. For validity, 508 patients were recruited and administered the EQ-5D, Short-Form 36 and condition-specific measures. Construct validity and sensitivity were evaluated by testing a-priori hypotheses. For reliability, another 57 patients repeated the EQ-5D at 1-week interval, and intra-class correlations (ICC) and kappa statistics were estimated. For responsiveness, another 60 patients repeated it at 12-week interval within the context of clinical trial, and standardized response mean(SRM) were calculated. The cross-cultural adaptation produced no major modifications in the scale. The associations of the EQ-5D with the generic- and condition-specific measures were observed as expected in hypotheses: the higher EQ-5Dindex and EQ-5D(VAS) scores, the better health status by generic- or condition-specific measures, and the better functional class. The ICCs were 0.751 and 0.767, respectively, and kappa ranged from 0.455 to 0.772. The SRM were 0.649 and 0.410, respectively. The Korean EQ-5D exhibits good validity and sensitivity in various rheumatic conditions. Although its reliability and responsiveness were not excellent, it seems acceptable if condition-specific measures are applied together.
Jerez-Molina, Carmen; Lázaro-Alcay, Juan J; Ullán-de la Fuente, Ana M
2017-10-17
Cross-cultural adaptation into Spanish of the Induction Compliance Checklist (ICC) for assessing children's behaviour during induction of anaesthesia. A descriptive cross-sectional observational study was conducted on a sample of 81 children aged 2 to 12 years operated in an ambulatory surgery unit of a paediatric hospital in Barcelona. Adaptation by translation-back translation of the tool and analysis of the scale's validity and reliability. Face validity of the tool was guaranteed through a discussion group and inter-observer reliability was evaluated, obtaining an intraclass correlation index of r = 0.956. The ICC scale validated for the Spanish population can be an effective tool for the presurgical evaluation of activities carried out to minimise children's anxiety. The ICC is an easy-to-use scale completed by operating room staff in one minute and would provide important information about children's behaviour, specifically during induction. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.
Lee, Ji Hyun; Cho, Kyoung Im; Spertus, John; Kim, Seong Man
2012-08-01
The Peripheral Artery Questionnaire (PAQ), as developed in US English, is a validated scale to evaluate the health status of patients with peripheral artery disease (PAD). The aim of this study was to translate the PAQ into Korean and to evaluate its reliability and validity. A multi-step process of forward-translation, reconciliation, consultation with the developer, back-translation and proofreading was conducted. The test-retest reliability was evaluated at a 2-week interval using the intra-class correlation coefficient (ICC). The validity was assessed by identifying associations between Korean PAQ (KPAQ) scores and Korean Health Assessment Questionnaire (KHAQ) scores. A total of 100 PAD patients were enrolled: 63 without and 37 with severe claudication. The reliability of the KPAQ was adequate, with an ICC of 0.71. There were strong correlations between KPAQ's subscales. Cronbach's alpha for the summary score was 0.94, indicating good internal consistency and congruence with the original US version. The validity was supported by a significant correlation between the total KHAQ score and KPAQ physical function, stability, symptom, social limitation and quality of life scores (r = -0.24 to -0.90; p < 0.001) as well as between the KHAQ walking subscale and the KPAQ physical function score (r = -0.55, p < 0.001). Our results indicate that the KPAQ is a reliable, valid instrument to evaluate the health status of Korean patients with PAD.
Tamez-Peña, Jose-Gerardo; Rodriguez-Rojas, Juan-Andrés; Gomez-Rueda, Hugo; Celaya-Padilla, Jose-Maria; Rivera-Prieto, Roxana-Alicia; Palacios-Corona, Rebeca; Garza-Montemayor, Margarita; Cardona-Huerta, Servando; Treviño, Victor
2018-01-01
In breast cancer, well-known gene expression subtypes have been related to a specific clinical outcome. However, their impact on the breast tissue phenotype has been poorly studied. Here, we investigate the association of imaging data of tumors to gene expression signatures from 71 patients with breast cancer that underwent pre-treatment digital mammograms and tumor biopsies. From digital mammograms, a semi-automated radiogenomics analysis generated 1,078 features describing the shape, signal distribution, and texture of tumors along their contralateral image used as control. From tumor biopsy, we estimated the OncotypeDX and PAM50 recurrence scores using gene expression microarrays. Then, we used multivariate analysis under stringent cross-validation to train models predicting recurrence scores. Few univariate features reached Spearman correlation coefficients above 0.4. Nevertheless, multivariate analysis yielded significantly correlated models for both signatures (correlation of OncotypeDX = 0.49 ± 0.07 and PAM50 = 0.32 ± 0.10 in stringent cross-validation and OncotypeDX = 0.83 and PAM50 = 0.78 for a unique model). Equivalent models trained from the unaffected contralateral breast were not correlated suggesting that the image signatures were tumor-specific and that overfitting was not a considerable issue. We also noted that models were improved by combining clinical information (triple negative status and progesterone receptor). The models used mostly wavelets and fractal features suggesting their importance to capture tumor information. Our results suggest that molecular-based recurrence risk and breast cancer subtypes have observable radiographic phenotypes. To our knowledge, this is the first study associating mammographic information to gene expression recurrence signatures.
Tamez-Peña, Jose-Gerardo; Rodriguez-Rojas, Juan-Andrés; Gomez-Rueda, Hugo; Celaya-Padilla, Jose-Maria; Rivera-Prieto, Roxana-Alicia; Palacios-Corona, Rebeca; Garza-Montemayor, Margarita; Cardona-Huerta, Servando
2018-01-01
In breast cancer, well-known gene expression subtypes have been related to a specific clinical outcome. However, their impact on the breast tissue phenotype has been poorly studied. Here, we investigate the association of imaging data of tumors to gene expression signatures from 71 patients with breast cancer that underwent pre-treatment digital mammograms and tumor biopsies. From digital mammograms, a semi-automated radiogenomics analysis generated 1,078 features describing the shape, signal distribution, and texture of tumors along their contralateral image used as control. From tumor biopsy, we estimated the OncotypeDX and PAM50 recurrence scores using gene expression microarrays. Then, we used multivariate analysis under stringent cross-validation to train models predicting recurrence scores. Few univariate features reached Spearman correlation coefficients above 0.4. Nevertheless, multivariate analysis yielded significantly correlated models for both signatures (correlation of OncotypeDX = 0.49 ± 0.07 and PAM50 = 0.32 ± 0.10 in stringent cross-validation and OncotypeDX = 0.83 and PAM50 = 0.78 for a unique model). Equivalent models trained from the unaffected contralateral breast were not correlated suggesting that the image signatures were tumor-specific and that overfitting was not a considerable issue. We also noted that models were improved by combining clinical information (triple negative status and progesterone receptor). The models used mostly wavelets and fractal features suggesting their importance to capture tumor information. Our results suggest that molecular-based recurrence risk and breast cancer subtypes have observable radiographic phenotypes. To our knowledge, this is the first study associating mammographic information to gene expression recurrence signatures. PMID:29596496
Rask, Marie; Oscarsson, Marie; Ludwig, Neil; Swahnberg, Katarina
2017-04-04
Cervical dysplasia is a precancerous condition, which has been shown to create anxiety in women. To be able to investigate these women's health-related quality of life, a disease-specific instrument is required. There does not seem to be a Swedish version of an instrument to screen for this specific disease. Therefore, this study aims to translate and cross-culturally adapt the Functional Assessment of Chronic Illness Therapy - Cervical Dysplasia (FACIT-CD) into a Swedish context and evaluate its linguistic validity and reliability. The Functional Assessment of Chronic Illness Therapy (FACIT) translation methodology was used, which consists of several steps including pilot testing of the FACIT-CD instrument through cognitive debriefing interviews. Ten women diagnosed with cervical dysplasia participated in the cognitive debriefing interviews. The internal consistency reliability of the Swedish FACIT-CD was estimated by Cronbach's alpha coefficient. Homogeneity of the items was evaluated by corrected item-total correlations. The sample consists of 34 women who were diagnosed with cervical dysplasia. The translation and cross-cultural adaptation went smoothly without any problems for the majority of the items. The cognitive debriefing interviews indicated that the Swedish FACIT-CD consists of relevant items, is easy to understand and complete, and has unambiguous and comprehensive response categories. The translation and cross-cultural adaptation resulted in a Swedish FACIT-CD, which is conceptually and semantically equivalent to the English version and linguistically valid. The total scale of the Swedish FACIT-CD exhibited good internal consistency reliability with a Cronbach's alpha coefficient of 0.84, and all of the subscales exhibited acceptable value between 0.71 and 0.81 except the Relationships subscale, which had a value of 0.67. Finally, all but four items exceeded the acceptable level for the corrected item-total correlations of ≥ 0.20. The Swedish FACIT-CD is conceptually and semantically equivalent to the English version and linguistically valid; further, it exhibits good internal consistency reliability.
Shabany, Maryam; Nasrabadi, Alireza Nikbakht; Rahimi-Movaghar, Vafa; Mansournia, Mohammad Ali; Mohammadi, Nooredin; Pruitt, Sheri D
2018-05-01
Cross-sectional psychometric study. To evaluate the reliability and validity of a spinal cord injury lifestyle scale (SCILS) and Health Behavior Questionnaire (HBQ) in the Persian language for persons with spinal cord injury (SCI). Participants were selected among those referred to health centers and the Brain and Spinal Cord Injury Research Center. In accordance with standard procedure for translation, two questionnaires, the SCILS and HBQ, were translated using a forward and backward translation approach by professional translators. Face validity of the questionnaires was assessed by ten persons with SCI and content validity was agreed upon by 12 professors from health care teaching universities. To test the final versions of both questionnaires, 97 persons with SCI were included using a consecutive sampling method. Other questionnaires were used to assess concurrent validity (secondary impairment checklist, as well as SCILS and HBQ) and convergent validity (impact of event scale revised, brief symptom inventory, beck depression inventory, and functional independence measure). Internal consistency of SCILS and HBQ, assessed by Cronbach's alpha, was 0.75 for SCILS and 0.85 for HBQ. Test-retest reliability intraclass correlations were 0.86 and 0.92 for SCILS and HBQ, respectively. The number of current secondary impairments had a significant and negative correlation with SCILS (r = -0.22, P < 0.001), but it was not correlated with HBQ. SCILS had a significant and strong correlation with HBQ (r = 0.65, P < 0.001). SCILS and HBQ can be used for measuring the health behavior of persons with SCI in Iran.
A Monte Carlo Evaluation of Estimated Parameters of Five Shrinkage Estimate Formuli.
ERIC Educational Resources Information Center
Newman, Isadore; And Others
A Monte Carlo study was conducted to estimate the efficiency of and the relationship between five equations and the use of cross validation as methods for estimating shrinkage in multiple correlations. Two of the methods were intended to estimate shrinkage to population values and the other methods were intended to estimate shrinkage from sample…
ERIC Educational Resources Information Center
Russell, Stephen T.; Crockett, Lisa J.; Shen, Yuh-Ling; Lee, Sun-A
2008-01-01
Self-esteem and depression are fundamental psychological adjustment constructs in the study of adolescent well-being. Most measures of these constructs have been developed and validated using European American samples, and while the correlates and predictors of psychological adjustment have been examined in multiple cultural settings, no existing…
Chan, Raymond C K; Wang, Ya; Huang, Jia; Shi, Yanfang; Wang, Yuna; Hong, Xiaohong; Ma, Zheng; Li, Zhanjian; Lai, M K; Kring, Ann M
2010-01-30
This study examined anticipatory and consummatory pleasure in schizophrenia patients with and without negative symptoms. Negative symptom patients experienced less anticipatory pleasure than non-negative symptom patients; only one facet of consummatory pleasure was unaffected in negative schizophrenia. Greater pleasure deficits were correlated with more severe positive and negative symptoms.
Kyrölä, Kati; Järvenpää, Salme; Ylinen, Jari; Mecklin, Jukka-Pekka; Repo, Jussi Petteri; Häkkinen, Arja
2017-06-15
A prospective clinical study to test and adapt a Finnish version of the Scoliosis Research Society 30 (SRS-30) questionnaire. The aim of this study was to perform cross-cultural adaptation and evaluate the validity of the adapted Finnish version of the SRS-30 questionnaire. The SRS-30 questionnaire has proved to be a valid instrument in evaluating health-related quality of life (HRQoL) in adolescent and adult population with spine deformities in the United States. Multinational availability requires cross-cultural and linguistic adaptation and validation of the instrument. The SRS-30 was translated into Finnish using accepted methods for translation of quality-of-life questionnaires. A total of 274 adult patients with degenerative radiographic sagittal spinal disorder answered the questionnaire with sociodemographic data, RAND 36-item health survey questionnaire (RAND Corp. Health, Santa Monica, CA, US), Oswestry disability index, DEPS depression scale, and Visual Analog Scale (VAS) back and leg pain scales within 2 weeks' interval. The cohort included patients with and without previous spine surgery. Internal consistency and validity were tested with Cronbach α, intraclass correlation (ICC), standard error of measurement, and Spearman correlation coefficient with 95% confidence intervals (CIs). The internal consistency of SRS-30 was good in both surgery and nonsurgery groups, with Cronbach α 0.853 (95% CI, 0.670 to 0.960) and 0.885 (95% CI, 0.854 to 0.911), respectively. The test-retest reproducibility ICC of the SRS-30 total and subscore domains of patients with stable symptoms was 0.905 (95% CI, 0.870-0.930) and 0.904 (95% CI, 0.871-0.929), respectively. The questionnaire had discriminative validity in the pain, self-image, and satisfaction with management domains compared with other questionnaires. The SRS-30 questionnaire proved to be valid and applicable in evaluating HRQoL in Finnish adult spinal deformity patients. It has two domains related to deformity that are not covered by other generally used questionnaires. 3.
Measuring and Validating Neutron Capture Cross Sections Using a Lead Slowing-Down Spectrometer
NASA Astrophysics Data System (ADS)
Thompson, Nicholas
Accurate nuclear data is essential for the modeling, design, and operation of nuclear systems. In this work, the Rensselaer Polytechnic Institute (RPI) Lead Slowing-Down Spectrometer (LSDS) at the Gaerttner Linear Accelerator Center (LINAC) was used to measure neutron capture cross sections and validate capture cross sections in cross section libraries. The RPI LINAC was used to create a fast burst of neutrons in the center of the LSDS, a large cube of high purity lead. A sample and YAP:Ce scintillator were placed in the LSDS, and as neutrons lost energy through scattering interactions with the lead, the scintillator detected capture gammas resulting from neutron capture events in the sample. Samples of silver, gold, cobalt, iron, indium, molybdenum, niobium, nickel, tin, tantalum, and zirconium were measured. Data was collected as a function of time after neutron pulse, or slowing-down time, which is correlated to average neutron energy. An analog and a digital data acquisition system collected data simultaneously, allowing for collection of pulse shape information as well as timing. Collection of digital data allowed for pulse shape analysis after the experiment. This data was then analyzed and compared to Monte Carlo simulations to validate the accuracy of neutron capture cross section libraries. These measurements represent the first time that neutron capture cross sections have been measured using an LSDS in the United States, and the first time tools such as coincidence measurements and pulse height weighting have been applied to measurements of neutron capture cross sections using an LSDS. Significant differences between measurement results and simulation results were found in multiple materials, and some errors in nuclear data libraries have already been identified due to these measurements.
Ullrich-French, Sarah; González Hernández, Juan; Hidalgo Montesinos, María D
2017-02-01
Mindfulness is an increasingly popular construct with promise in enhancing multiple positive health outcomes. Physical activity is an important behavior for enhancing overall health, but no Spanish language scale exists to test how mindfulness during physical activity may facilitate physical activity motivation or behavior. This study examined the validity of a Spanish adaption of a new scale, the State Mindfulness Scale for Physical Activity, to assess mindfulness during a specific experience of physical activity. Spanish youths (N = 502) completed a cross-sectional survey of state mindfulness during physical activity and physical activity motivation regulations based on Self-Determination Theory. A high-order model fit the data well and supports the use of one general state mindfulness factor or the use of separate subscales of mindfulness of mental (e.g., thoughts, emotions) and body (physical movement, muscles) aspects of the experience. Internal consistency reliability was good for the general scale and both sub-scales. The pattern of correlations with motivation regulations provides further support for construct validity with significant and positive correlations with self-determined forms of motivation and significant and negative correlations with external regulation and amotivation. Initial validity evidence is promising for the use of the adapted measure.
Marchese, C; Cristalli, G; Pichi, B; Manciocco, V; Mercante, G; Pellini, R; Marchesi, P; Sperduti, I; Ruscito, P; Spriano, G
2012-02-01
Shoulder syndrome after neck dissection is a well known entity, but its incidence and prognostic factors influencing recovery have not been clearly assessed due to the heterogeneity of possible evaluations. The University of California - Los Angeles (UCLA) Shoulder Scale, the Shoulder Pain and Disability Index (SPADI) and the Simple Shoulder Test (SST) are three English-language questionnaires commonly used to test shoulder impairment. An Italian version of these scales is not available. The aim of the present study was to translate, culturally adapt and validate an Italian version of UCLA Shoulder Scale, SPADI and SST. Translation and cross-cultural adaptation of the SPADI, the UCLA shoulder scale and the SST was performed according to the international guidelines. Sixty-six patients treated with neck dissection for head and neck cancer were called to draw up these scales. Forty patients completed the same questionnaires a second time one week after the first to test the reproducibility of the Italian versions. All the English-speaking Italian patients (n = 11) were asked to complete both the English and the Italian versions of the three questionnaires to validate the scales. No major problems regarding the content or the language were found during the translation of the 3 questionnaires. For all three scales, Cronbach's α was > 0.89. The Pearson correlation coefficient was r > 0.91. With respect to validity, there was a significant correlation between the Italian and the English versions of all three scales. This study shows that the Italian versions of UCLA Shoulder Scale, SPADI and SST are valid instruments for the evaluation of shoulder dysfunction after neck dissection in Italian patients.
Pelegrino, Flávia M; Dantas, Rosana A S; Corbi, Inaiara S A; da Silva Carvalho, Ariana R; Schmidt, André; Pazin Filho, Antônio
2012-09-01
The aim of this study was to evaluate the internal reliability and validity of the Brazilian-Portuguese version of Duke Anticoagulation Satisfaction Scale (DASS) among cardiovascular patients. Oral anticoagulation is widely used to prevent and treat thromboembolic events in several conditions, especially in cardiovascular diseases; however, this therapy can induce dissatisfaction and reduce the quality of life. Methodological and cross-sectional research design. The cultural adaptation of the DASS included the translation and back-translation, discussions with healthcare professionals and patients to ensure conceptual equivalence, semantic evaluation and instrument pretest. The Brazilian-Portuguese version of the DASS was tested among subjects followed in a university hospital anticoagulation outpatient clinic. The psychometric properties were assessed by construct validity (convergent, known groups and dimensionality) and internal consistency/reliability (Cronbach's alpha). A total of 180 subjects under oral anticoagulation formed the baseline validation population. DASS total score and SF-36 domain correlations were moderate for General health (r=-0.47, p<0.01), Vitality (r=-0.44, p<0.01) and Mental health (r=-0.42, p<0.01) (convergent). Age and length on oral anticoagulation therapy (in years) were weakly correlated with total DASS score and most of the subscales, except Limitation (r=-0.375, p<0.01) (Known groups). The Cronbach's alpha coefficient was 0.79 for the total scale, and it ranged from 0.76 (hassles and burdens)-0.46 (psychological impact) among the domains, confirming the internal consistency reliability. The Brazilian-Portuguese version of the DASS has shown levels of reliability and validity comparable with the original English version. Healthcare practitioners and researchers need internationally validated measurement tools to compare outcomes of interventions in clinical management and research tools in oral anticoagulation therapy. © 2011 Blackwell Publishing Ltd.
Transcultural Adaptation and Validation of the German Version of the Vocal Tract Discomfort Scale.
Lukaschyk, Julia; Brockmann-Bauser, Meike; Beushausen, Ulla
2017-03-01
Currently, there is no standardized German questionnaire to assess vocal tract discomfort in voice patients. The aim of this study was to evaluate the internal consistency, reliability, and validity of the German version of the Vocal Tract Discomfort (VTD) Scale. This is a cross-sectional study. First, a cross-cultural translation and adaptation from English to German was performed. One hundred seven patients between the ages of 18 and 76 with voice disorders were divided into two different diagnosis-related groups (organic and functional voice disorder) and 50 vocally healthy adults were included. All participants completed the VTD Scale and the Voice Handicap Index (VHI). The internal consistency of the VTD Scale was analyzed through Cronbach's α coefficient. Pearson correlation between the VDT Scale and VHI total scores was used to determine criterion validity. The VDT Scale score differences related to diagnosis groups were assessed with analysis of variance. Excellent internal consistency was found (α = 0.919, P < 0.05), and criterion validity was confirmed by a high correlation between the total VTD Scale and VHI (r = 0.674). There was a significant difference between the diagnosis groups' total VTD Scale score (F[4.135] = 15.114, P = 0.000). Furthermore, the vocally healthy adults had significantly lower values than the two diagnosis groups (x¯: 11.48, s = 8.340). The German version of the VTD Scale has an excellent internal consistency and reliability, and shows high clinical validity. Thus, it is a useful instrument in voice diagnostics. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Pilar Orive, Francisco Javier; Basabe Lozano, Jasone; López Zuñiga, Aurora; López Fernández, Yolanda M; Escudero Argaluza, Julene; Latour, Jos M
2017-11-03
Few validated surveys measuring parental satisfaction in the Paediatric Intensive Care Unit (PICU) are available, and none of them in Spanish language. The aim of this study is to translate and validate the questionnaire EMpowerment of PArents in THe Intensive Care (EMPATHIC). This questionnaire measures parental perceptions of paediatric intensive care-related satisfaction items in the Spanish language. A prospective cohort study was carried out using questionnaires completed by relatives of children (range 0-17 years old) admitted into a tertiary PICU. Inclusion criteria were a length of stay more than 24h, and a suitable understanding of Spanish language by parents or guardians. Exclusion criteria were re-admissions and deceased patients. The questionnaire was translated from English to Spanish language using a standardised procedure, after which it was used in a cross-sectional observational study was performed to confirm its validity and consistency. Reliability was estimated using Cronbach's α, and content validity using Spearman's correlation analysis. A total of 150 questionnaires were collected. A Cronbach's α was obtained for domains greater than 0.7, showing a high internal consistency from the questionnaire. Validity was measured by correlating 5 domains with 4 general satisfaction items, documenting an adequate correlation (Rs: 0.41-0.66, P<.05). The Spanish version of EMPHATIC 30 is a feasible, easy, and suitable tool in this specific environment, based on the results. EMPATHIC 30 is able to measure parental satisfaction, and may serve as a valid indicator to measure quality of care in Spanish PICUs. Copyright © 2017. Publicado por Elsevier España, S.L.U.
Areia, Neide P; Major, Sofia; Relvas, Ana P
2017-10-01
The aim of this study was to validate the Portuguese version of the Family Inventory of Needs (FIN). The FIN aims to measure important family needs and their fulfilment by a healthcare team. This cross-sectional study involved a sample of 364 family members of cancer patients, recruited from three medical institutions and through online recruitment. Three instruments were used: a socio-demographic questionnaire, the FIN and the Brief Symptom Inventory - 18 (BSI-18). Construct validity and reliability were considered regarding the FIN's psychometric properties. The method used to determine construct validity was factor structure analysis (confirmatory factor analysis), inter-factor correlations (Spearman's rank correlation) and convergent validity (Spearman's rank correlation). To assess scale reliability, the FIN's internal consistency was evaluated (Cronbach's alpha coefficient). Descriptive and frequency statistics and tests to compare means were used to assess important needs and to what extent they were met. The four-factor structure of the FIN was confirmed. Thus, the FIN has four domains: Basic Information, Information on treatment and care, Support and Patient Comfort. Convergent validity with the BSI-18 was verified. Both subscales of the FIN and each domain exceeded the minimum reliability standard of 0.70. Family members also reported important needs that were not adequately met by healthcare professionals. The Portuguese version of the FIN seems to be a reliable and valid tool for identifying cancer patients' important family needs and to what extent these are met. Copyright © 2017 Elsevier Ltd. All rights reserved.
Boonstra, Anne M; Schiphorst Preuper, Henrica R; Reneman, Michiel F; Posthumus, Jitze B; Stewart, Roy E
2008-06-01
To determine the reliability and concurrent validity of a visual analogue scale (VAS) for disability as a single-item instrument measuring disability in chronic pain patients was the objective of the study. For the reliability study a test-retest design and for the validity study a cross-sectional design was used. A general rehabilitation centre and a university rehabilitation centre was the setting for the study. The study population consisted of patients over 18 years of age, suffering from chronic musculoskeletal pain; 52 patients in the reliability study, 344 patients in the validity study. Main outcome measures were as follows. Reliability study: Spearman's correlation coefficients (rho values) of the test and retest data of the VAS for disability; validity study: rho values of the VAS disability scores with the scores on four domains of the Short-Form Health Survey (SF-36) and VAS pain scores, and with Roland-Morris Disability Questionnaire scores in chronic low back pain patients. Results were as follows: in the reliability study rho values varied from 0.60 to 0.77; and in the validity study rho values of VAS disability scores with SF-36 domain scores varied from 0.16 to 0.51, with Roland-Morris Disability Questionnaire scores from 0.38 to 0.43 and with VAS pain scores from 0.76 to 0.84. The conclusion of the study was that the reliability of the VAS for disability is moderate to good. Because of a weak correlation with other disability instruments and a strong correlation with the VAS for pain, however, its validity is questionable.
Bruscky, Dayanne Mota Veloso; Melo, Ana Caroline Cavalcanti Dela Bianca; Sarinho, Emanuel Sávio Cavalcanti
2017-01-01
ABSTRACT Objective: To translate, adapt and validate the Itch Severity Scale to a Brazilian version (ISS-Ped) in order to measure the severity of pruritus in children and adolescents with atopic dermatitis. Methods: This is a methodological study of validation of an instrument following recommended protocols. The translated version was evaluated by a group of experts including one professional with experience in instrument validation, three English teachers, one linguistics teacher and seven allergists. After this, the scale was applied to 42 parents of children aged between 2 and 18 years old with atopic dermatitis, and 42 parents of children without pruritic diseases. Results were evaluated according to the severity of atopic dermatitis and disease control, and they were compared between groups with and without atopic dermatitis. Results: More than 90% of the questions were clear to the parents. The ISS-Ped showed a strong positive correlation with the severity of atopic dermatitis (Pearson: 0.74; p<0.001) and a good correlation with the control of dermatitis (point-biserial correlation coefficient: 0.65; p<0.001). The scale showed excellent internal consistency (Cronbach’s α: 0.96) and adequate test and retest agreement (95% confidence interval of intraclass correlation coefficient: 0.89-0.99; p<0.001). Conclusions: The ISS-Ped is a feasible, valid, reliable and satisfactorily equivalent. The translated scale was appropriate to assess the severity of itching in children and adolescents with eczema, allowing comparisons in the clinical practice and in the research setting. PMID:28977301
Messner, Steven F.; Raffalovich, Lawrence E.; Sutton, Gretchen M.
2011-01-01
This paper assesses the extent to which the infant mortality rate might be treated as a “proxy” for poverty in research on cross-national variation in homicide rates. We have assembled a pooled, cross-sectional time-series dataset for 16 advanced nations over the 1993–2000 period that includes standard measures of infant mortality and homicide and also contains information on two commonly used “income-based” poverty measures: a measure intended to reflect “absolute” deprivation and a measure intended to reflect “relative” deprivation. With these data, we are able to assess the criterion validity of the infant mortality rate with reference to the two income-based poverty measures. We are also able to estimate the effects of the various indicators of disadvantage on homicide rates in regression models, thereby assessing construct validity. The results reveal that the infant mortality rate is more strongly correlated with “relative poverty” than with “absolute poverty,” although much unexplained variance remains. In the regression models, the measure of infant mortality and the relative poverty measure yield significant positive effects on homicide rates, while the absolute poverty measure does not exhibit any significant effects. Our analyses suggest that it would be premature to dismiss relative deprivation in cross-national research on homicide, and that disadvantage is best conceptualized and measured as a multidimensional construct. PMID:21643432
Validation of the Hebrew version of the Burn Specific Health Scale-Brief questionnaire.
Stavrou, Demetris; Haik, Josef; Wiser, Itay; Winkler, Eyal; Liran, Alon; Holloway, Samantha; Boyd, Julie; Zilinsky, Isaac; Weissman, Oren
2015-02-01
The Burns Specific Health Scale-Brief (BSHS-B) questionnaire is a suitable measurement tool for the assessment of general, physical, mental, and social health aspects of the burn survivor. To translate, culturally adapt and validate the BSHS-B to Hebrew (BSHS-H), and to investigate its psychometric properties. Eighty-six Hebrew speaking burn survivors filled out the BSHS-B and SF-36 questionnaires. Ten of them (11.63%) completed a retest. The psychometric properties of the scale were evaluated. Internal consistency, criterion validity, and construct validity were assessed using interclass correlation coefficient, Cronbach's alpha statistic, Spearman rank test, and Mann-Whitney U test respectively. BSHS-H Cronbach's alpha coefficient was 0.97. Test-retest interclass coefficients were between 0.81 and 0.98. BSHS-H was able to discriminate between facial burns, hand burns and burns >10% body surface area (p<0.05). BSHS-H and SF-36 were positively correlated (r(2)=0.667, p<0.01). BSHS-H is a reliable and valid instrument for use in the Israeli burn survivor population. The translation and cross-cultural adaptation of this disease specific scale allows future comparative international studies. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Learning Style Scales: a valid and reliable questionnaire.
Abdollahimohammad, Abdolghani; Ja'afar, Rogayah
2014-01-01
Learning-style instruments assist students in developing their own learning strategies and outcomes, in eliminating learning barriers, and in acknowledging peer diversity. Only a few psychometrically validated learning-style instruments are available. This study aimed to develop a valid and reliable learning-style instrument for nursing students. A cross-sectional survey study was conducted in two nursing schools in two countries. A purposive sample of 156 undergraduate nursing students participated in the study. Face and content validity was obtained from an expert panel. The LSS construct was established using principal axis factoring (PAF) with oblimin rotation, a scree plot test, and parallel analysis (PA). The reliability of LSS was tested using Cronbach's α, corrected item-total correlation, and test-retest. Factor analysis revealed five components, confirmed by PA and a relatively clear curve on the scree plot. Component strength and interpretability were also confirmed. The factors were labeled as perceptive, solitary, analytic, competitive, and imaginative learning styles. Cronbach's α was >0.70 for all subscales in both study populations. The corrected item-total correlations were >0.30 for the items in each component. The LSS is a valid and reliable inventory for evaluating learning style preferences in nursing students in various multicultural environments.
Akpinar, Pinar; Tezel, Canan G; Eliasson, Ann-Christin; Icagasioglu, Afitap
2010-01-01
To determine the reliability and cross-cultural validation of the Turkish translation of the Manual Ability Classification System (MACS) for children with cerebral palsy (CP) and to investigate the relation to gross motor function and other comorbidities. After the forward and backward translation procedures, inter-rater and test-retest reliability was assessed between parents, physiotherapists and physicians using the intra-class correlation coefficient (ICC). Children (N = 118, 4 to 18 years, mean age 9 years 4 months; 68 boys, 50 girls) with various types of CP were classified. Additional data on the Gross Motor Function Classification System (GMFCS), intellectual delay, visual acuity, and epilepsy were collected. The inter-rater reliability was high; the ICC ranged from 0.89 to 0.96 among different professionals and parents. Between two persons of the same profession it ranged from 0.97 to 0.98. For the test-retest reliability it ranged from 0.91 to 0.98. Total agreement between the GMFCS and the MACS occurred in only 45% of the children. The level of the MACS was found to correlate with the accompanying comorbidities, namely intellectual delay and epilepsy. The Turkish version of the MACS is found to be valid and reliable, and is suggested to be appropriate for the assessment of manual ability within the Turkish population.
[Validity and Reliability of Korean Version of the Spiritual Care Competence Scale].
Chung, Mi Ja; Park, Youngrye; Eun, Young
2016-12-01
The aim of this study was to examine the validity and reliability of the Korean Version of the Spiritual Care Competence Scale (K-SCCS). A cross-sectional study design was used. The K-SCCS consisted of 26 questions to measure spiritual care competence of nurses. Participants, 228 nurses who had more than 3 years'experience as a nurse, completed the survey. Confirmatory factor analysis was used to examine the construct validity and correlations of K-SCCS and spiritual well-being (SWB) were used to examine the criterion validity of K-SCCS. Cronbach's alpha was used to test internal consistency. The construct and the criterion-related validity of K-SCCS were supported as measures of spiritual care competence. Cronbach's alpha was .95. Factor loadings of the 26 questions ranged from .60 to .96. Construct validity of K-SCCS was verified by confirmatory factor analysis (RMSEA=.08, CFI=.90, NFI=.85). Criterion validity compared to the SWB showed significant correlation (r=.44, p<.001). The findings suggest that K-SCCS serves as an appropriate measure of spiritual care competence with validity and reliability. However, further study is needed to retest the verification of the factor analysis related to factor 2 (professionalisation and improving the quality of spiritual care) and factor 3 (personal support and patient counseling). Therefore, we recommend using the total score without distinguishing subscales.
Simonelli, A; Sacchi, C; Cantoni, L; Brown, M; Frewen, P
2017-01-01
Background : The Childhood Attachment and Relational Trauma Screen (CARTS) is a computer-administered survey designed to assess retrospectively the socio-ecological context in which instances of child abuse may have occurred. To date, studies supporting the validity of the CARTS have only been undertaken in English-speaking North American populations. Validation projects in other countries and cross-cultural comparisons are therefore warranted. Objective : Develop and preliminarily evaluate the psychometric properties of an Italian version of the CARTS on college students and compare such observations to data acquired from Canadian students. Method : Seventy-nine undergraduate students from the University of Padua (Italy) completed an Italian translation of the CARTS as well as measures of childhood experiences, mental health and attachment, responses to which were compared to those obtained in 288 Canadian students who completed the CARTS in English. Results : Internal consistency and convergent validity with the Childhood Trauma Questionnaire and Parental Bonding Instrument were found to be acceptable for the Italian translation. Within the Italian sample, correlation analyses suggested that CARTS Mother ratings referring to attachment and abuse were associated with romantic attachment, whereas CARTS Father ratings were significantly correlated to PTSD symptoms and other symptoms of psychopathology-distress. Significant differences between Italian and Canadian students across the relationship types for the CARTS abuse and attachment scales were found, indicating that Italian students rated their mothers and fathers as simultaneously less abusive, but also less as a source of secure attachment. Conclusions : The results of this preliminary study seem to suggest convergent validity of the Italian CARTS and the association between childhood attachment-related experiences and romantic attachment. Cultural variations were identified between Canadian and Italian students in both attachment and abuse scales. Future studies to investigate cross-cultural variations in the relational context of childhood abuse and in order to boost Italian CARTS psychometric features are warranted.
Simonelli, A.; Sacchi, C.; Cantoni, L.; Brown, M.; Frewen, P.
2017-01-01
ABSTRACT Background: The Childhood Attachment and Relational Trauma Screen (CARTS) is a computer-administered survey designed to assess retrospectively the socio-ecological context in which instances of child abuse may have occurred. To date, studies supporting the validity of the CARTS have only been undertaken in English-speaking North American populations. Validation projects in other countries and cross-cultural comparisons are therefore warranted. Objective: Develop and preliminarily evaluate the psychometric properties of an Italian version of the CARTS on college students and compare such observations to data acquired from Canadian students. Method: Seventy-nine undergraduate students from the University of Padua (Italy) completed an Italian translation of the CARTS as well as measures of childhood experiences, mental health and attachment, responses to which were compared to those obtained in 288 Canadian students who completed the CARTS in English. Results: Internal consistency and convergent validity with the Childhood Trauma Questionnaire and Parental Bonding Instrument were found to be acceptable for the Italian translation. Within the Italian sample, correlation analyses suggested that CARTS Mother ratings referring to attachment and abuse were associated with romantic attachment, whereas CARTS Father ratings were significantly correlated to PTSD symptoms and other symptoms of psychopathology-distress. Significant differences between Italian and Canadian students across the relationship types for the CARTS abuse and attachment scales were found, indicating that Italian students rated their mothers and fathers as simultaneously less abusive, but also less as a source of secure attachment. Conclusions: The results of this preliminary study seem to suggest convergent validity of the Italian CARTS and the association between childhood attachment-related experiences and romantic attachment. Cultural variations were identified between Canadian and Italian students in both attachment and abuse scales. Future studies to investigate cross-cultural variations in the relational context of childhood abuse and in order to boost Italian CARTS psychometric features are warranted. PMID:29163857
Validation of a French Version of the Quality of Life “Celiac Disease Questionnaire”
Pouchot, Jacques; Despujol, Carole; Malamut, Georgia; Ecosse, Emmanuel; Coste, Joël; Cellier, Christophe
2014-01-01
Background and Objective Celiac disease (CD) is a common chronic autoimmune disorder. Both the manifestations of the disease and the burden of the compulsory life-long gluten-free diet (GFD) have been shown to be associated with impairment of health-related quality of life. The objectives of this study were to provide a cross-cultural adaptation of the specific quality of life “Celiac Disease Questionnaire” (CDQ) and to analyze its psychometric properties. Materials and Methods A cross-cultural French adaptation of the CDQ (F-CDQ) was obtained according to the revised international guidelines. The questionnaire was administered at baseline to 211 patients with biopsy proven CD followed-up in a single tertiary referral centre. The questionnaire was also administered after 7 days and 6 months. Reliability (intraclass correlation coefficients (ICC), Cronbach's alpha and Bland and Altman graphical analysis), validity (factorial structure and Rasch analysis, convergent validity), and responsiveness (effect size) of the F-CDQ were studied. Results The reliability of the F-CDQ was excellent with ICC and Cronbach's alpha coefficients being between 0.79 and 0.94 for the four subscales and the total score. The factorial structure and the Rasch analysis showed that the four dimensions of the original instrument were retained. Correlations with external measures (a generic measure of quality of life, an anxiety and depression instrument, a self-assessed disease severity, and clinical manifestations) were all in the expected direction confirming the validity of the instrument. Responsiveness was studied and effect sizes ≥0.20 were demonstrated for most of the subscales for patients who reported improvement or deterioration after 6 months. Conclusion The F-CDQ retains the psychometric properties of the original instrument and should be useful in cross-national surveys and to assess outcome in clinical trials involving patients with CD. PMID:24788794
Hammond, Kendra; Mampilly, Jobby; Laghi, Franco A; Goyal, Amit; Collins, Eileen G; McBurney, Conor; Jubran, Amal; Tobin, Martin J
2014-01-01
Muscle-mass loss augers increased morbidity and mortality in critically ill patients. Muscle-mass loss can be assessed by wide linear-array ultrasound transducers connected to cumbersome, expensive console units. Whether cheaper, hand-carried units equipped with curved-array transducers can be used as alternatives is unknown. Accordingly, our primary aim was to investigate in 15 nondisabled subjects the validity of measurements of rectus femoris cross-sectional area by using a curved-array transducer against a linear-array transducer-the reference-standard technique. In these subjects, we also determined the reliability of measurements obtained by a novice operator versus measurements obtained by an experienced operator. Lastly, the relationship between quadriceps strength and rectus area recorded by two experienced operators with a curved-array transducer was assessed in 17 patients with chronic obstructive pulmonary disease (COPD). In nondisabled subjects, the rectus cross-sectional area measured with the curved-array transducer by the novice and experienced operators was valid (intraclass correlation coefficient [ICC]: 0.98, typical percentage error [%TE]: 3.7%) and reliable (ICC: 0.79, %TE: 9.7%). In the subjects with COPD, both reliability (ICC: 0.99) and repeatability (%TE: 7.6% and 9.8%) were high. Rectus area was related to quadriceps strength in COPD for both experienced operators (coefficient of determination: 0.67 and 0.70). In conclusion, measurements of rectus femoris cross-sectional area recorded with a curved-array transducer connected to a hand-carried unit are valid, reliable, and reproducible, leading us to contend that this technique is suitable for cross-sectional and longitudinal studies.
Synkinesis assessment in facial palsy: validation of the Dutch Synkinesis Assessment Questionnaire.
Kleiss, Ingrid J; Beurskens, Carien H G; Stalmeier, Peep F M; Ingels, Koen J A O; Marres, Henri A M
2016-06-01
The objective of this study is to validate an existing health-related quality of life questionnaire for patients with synkinesis in facial palsy for implementation in the Dutch language and culture. The Synkinesis Assessment Questionnaire was translated into the Dutch language using a forward-backward translation method. A pilot test with the translated questionnaire was performed in 10 patients with facial palsy and 10 normal subjects. Finally, cross-cultural adaption was accomplished at our outpatient clinic for facial palsy. Analyses for internal consistency, test-retest reliability, and construct validity were performed. Sixty-six patients completed the Dutch Synkinesis Assessment Questionnaire and the Dutch Facial Disability Index. Cronbach's α, representing internal consistency, was 0.80. Test-retest reliability was 0.53 (Spearman's correlation coefficient, P < 0.01). Correlations with the House-Brackmann score, Sunnybrook score, Facial Disability Index physical function, and social/well-being function were -0.29, 0.20, -0.29, and -0.32, respectively. Correlation with the Sunnybrook synkinesis subscore was 0.50 (Spearman's correlation coefficient). The Dutch Synkinesis Assessment Questionnaire shows good psychometric values and can be implemented in the management of Dutch-speaking patients with facial palsy and synkinesis in the Netherlands. Translation of the instrument into other languages may lead to widespread use, making evaluation, and comparison possible among different providers.
Extensive validation of the pain disability index in 3 groups of patients with musculoskeletal pain.
Soer, Remko; Köke, Albère J A; Vroomen, Patrick C A J; Stegeman, Patrick; Smeets, Rob J E M; Coppes, Maarten H; Reneman, Michiel F
2013-04-20
A cross-sectional study design was performed. To validate the pain disability index (PDI) extensively in 3 groups of patients with musculoskeletal pain. The PDI is a widely used and studied instrument for disability related to various pain syndromes, although there is conflicting evidence concerning factor structure, test-retest reliability, and missing items. Additionally, an official translation of the Dutch language version has never been performed. For reliability, internal consistency, factor structure, test-retest reliability and measurement error were calculated. Validity was tested with hypothesized correlations with pain intensity, kinesiophobia, Rand-36 subscales, Depression, Roland-Morris Disability Questionnaire, Quality of Life, and Work Status. Structural validity was tested with independent backward translation and approval from the original authors. One hundred seventy-eight patients with acute back pain, 425 patients with chronic low back pain and 365 with widespread pain were included. Internal consistency of the PDI was good. One factor was identified with factor analyses. Test-retest reliability was good for the PDI (intraclass correlation coefficient, 0.76). Standard error of measurement was 6.5 points and smallest detectable change was 17.9 points. Little correlations between the PDI were observed with kinesiophobia and depression, fair correlations with pain intensity, work status, and vitality and moderate correlations with the Rand-36 subscales and the Roland-Morris Disability Questionnaire. The PDI-Dutch language version is internally consistent as a 1-factor structure, and test-retest reliable. Missing items seem high in sexual and professional items. Using the PDI as a 2-factor questionnaire has no additional value and is unreliable.
Jeannerat, Damien
2017-01-01
The introduction of a universal data format to report the correlation data of 2D NMR spectra such as COSY, HSQC and HMBC spectra will have a large impact on the reliability of structure determination of small organic molecules. These lists of assigned cross peaks will bridge signals found in NMR 1D and 2D spectra and the assigned chemical structure. The record could be very compact, human and computer readable so that it can be included in the supplementary material of publications and easily transferred into databases of scientific literature and chemical compounds. The records will allow authors, reviewers and future users to test the consistency and, in favorable situations, the uniqueness of the assignment of the correlation data to the associated chemical structures. Ideally, the data format of the correlation data should include direct links to the NMR spectra to make it possible to validate their reliability and allow direct comparison of spectra. In order to take the full benefits of their potential, the correlation data and the NMR spectra should therefore follow any manuscript in the review process and be stored in open-access database after publication. Keeping all NMR spectra, correlation data and assigned structures together at all time will allow the future development of validation tools increasing the reliability of past and future NMR data. This will facilitate the development of artificial intelligence analysis of NMR spectra by providing a source of data than can be used efficiently because they have been validated or can be validated by future users. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Helou, Khalil; El Helou, Nour; Mahfouz, Maya; Mahfouz, Yara; Salameh, Pascale; Harmouche-Karaki, Mireille
2017-07-24
The International Physical Actvity Questionnaire (IPAQ) is a validated tool for physical activity assessment used in many countries however no Arabic version of the long-form of this questionnaire exists to this date. Hence, the aim of this study was to cross-culturally adapt and validate an Arabic version of the long International Physical Activity Questionnaire (AIPAQ) equivalent to the French version (F-IPAQ) in a Lebanese population. The guidelines for cross-cultural adaptation provided by the World Health Organization and the International Physical Activity Questionnaire committee were followed. One hundred fifty-nine students and staff members from Saint Joseph University of Beirut were randomly recruited to participate in the study. Items of the A-IPAQ were compared to those from the F-IPAQ for concurrent validity using Spearman's correlation coefficient. Content validity of the questionnaire was assessed using factor analysis for the A-IPAQ's items. The physical activity indicators derived from the A-IPAQ were compared with the body mass index (BMI) of the participants for construct validity. The instrument was also evaluated for internal consistency reliability using Cronbach's alpha and Intraclass Correlation Coefficient (ICC). Finally, thirty-one participants were asked to complete the A-IPAQ on two occasions three weeks apart to examine its test-retest reliability. Bland-Altman analyses were performed to evaluate the extent of agreement between the two versions of the questionnaire and its repeated administrations. A high correlation was observed between answers of the F-IPAQ and those of the A-IPAQ, with Spearman's correlation coefficients ranging from 0.91 to 1.00 (p < 0.05). Bland-Altman analysis showed a high level of agreement between the two versions with all values scattered around the mean for total physical activity (mean difference = 5.3 min/week, 95% limits of agreement = -145.2 to 155.8). Negative correlations were observed between MET values and BMI, independent of age, gender or university campus. The A-IPAQ showed a high internal consistency reliability with Cronbach's alpha ranging from 0.769-1.00 (p < 0.001) and intraclass correlation coefficient (ICC) ranging from 0.625-0.999 (p < 0.001), except for a moderate agreement with the moderate garden/yard activity (alpha = 0.682; ICC = 0.518; p < 0.001). The A-IPAQ had moderate-to-good test-retest reliability for most of its items (ICC ranging from 0.66-0.96; p < 0.001) and the Bland-Altman analysis showed a satisfactory agreement between the two administrations of the A-IPAQ for total physical activity (mean difference = 99.8 min/week, 95% limits of agreement = -1105.3; 1304.9) and total vigorous and moderate physical activity (mean difference = -29.7 min/week, 95% limits of agreement = -777.6; 718.2). The modified Arabic version of the IPAQ showed acceptable validity and reliability for the assessment of physical activity among Lebanese adults. More studies are necessary in the future to assess its validity compared to a gold-standard criterion measure.
The Arthroscopic Surgical Skill Evaluation Tool (ASSET)
Koehler, Ryan J.; Amsdell, Simon; Arendt, Elizabeth A; Bisson, Leslie J; Braman, Jonathan P; Butler, Aaron; Cosgarea, Andrew J; Harner, Christopher D; Garrett, William E; Olson, Tyson; Warme, Winston J.; Nicandri, Gregg T.
2014-01-01
Background Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. Hypothesis The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability, when used to assess the technical ability of surgeons performing diagnostic knee arthroscopy on cadaveric specimens. Study Design Cross-sectional study; Level of evidence, 3 Methods Content validity was determined by a group of seven experts using a Delphi process. Intra-articular performance of a right and left diagnostic knee arthroscopy was recorded for twenty-eight residents and two sports medicine fellowship trained attending surgeons. Subject performance was assessed by two blinded raters using the ASSET. Concurrent criterion-oriented validity, inter-rater reliability, and test-retest reliability were evaluated. Results Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in total ASSET score (p<0.05) between novice, intermediate, and advanced experience groups were identified. Inter-rater reliability: The ASSET scores assigned by each rater were strongly correlated (r=0.91, p <0.01) and the intra-class correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: there was a significant correlation between ASSET scores for both procedures attempted by each individual (r = 0.79, p<0.01). Conclusion The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopy in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live OR and other simulated environments. PMID:23548808
Van Lerbeirghe, J; Van Lerbeirghe, J; Van Schaeybroeck, P; Robijn, H; Rasschaert, R; Sys, J; Parlevliet, T; Hallaert, G; Van Wambeke, P; Depreitere, B
2018-01-01
The core outcome measures index (COMI) is a validated multidimensional instrument for assessing patient-reported outcome in patients with back problems. The aim of the present study is to translate the COMI into Dutch and validate it for use in native Dutch speakers with low back pain. The COMI was translated into Dutch following established guidelines and avoiding region-specific terminology. A total of 89 Dutch-speaking patients with low back pain were recruited from 8 centers, located in the Dutch-speaking part of Belgium. Patients completed a questionnaire booklet including the validated Dutch version of the Roland Morris disability questionnaire, EQ-5D, the WHOQoL-Bref, the Numeric Rating Scale (NRS) for pain, and the Dutch translation of the COMI. Two weeks later, patients completed the Dutch COMI translation again, with a transition scale assessing changes in their condition. The patterns of correlations between the individual COMI items and the validated reference questionnaires were comparable to those reported for other validated language versions of the COMI. The intraclass correlation for the COMI summary score was 0.90 (95% CI 0.84-0.94). It was 0.75 and 0.70 for the back and leg pain score, respectively. The minimum detectable change for the COMI summary score was 1.74. No significant differences were observed between repeated scores of individual COMI items or for the summary score. The reproducibility of the Dutch translation of the COMI is comparable to that of other validated spine outcome measures. The COMI items correlate well with the established item-specific scores. The Dutch translation of the COMI, validated by this work, is a reliable and valuable tool for spine centers treating Dutch-speaking patients and can be used in registries and outcome studies.
NASA Astrophysics Data System (ADS)
Lardner, Timothy; Li, Minghui; Gachagan, Anthony
2014-02-01
Materials with a coarse grain structure are becoming increasingly prevalent in industry due to their resilience to stress and corrosion. These materials are difficult to inspect with ultrasound because reflections from the grains lead to high noise levels which hinder the echoes of interest. Spatially Averaged Sub-Aperture Correlation Imaging (SASACI) is an advanced array beamforming technique that uses the cross-correlation between images from array sub-apertures to generate an image weighting matrix, in order to reduce noise levels. This paper presents a method inspired by SASACI to further improve imaging using phase information to refine focusing and reduce noise. A-scans from adjacent array elements are cross-correlated using both signal amplitude and phase to refine delay laws and minimize phase aberration. The phase-based and amplitude-based corrected images are used as inputs to a two-dimensional cross-correlation algorithm that will output a weighting matrix that can be applied to any conventional image. This approach was validated experimentally using a 5MHz array a coarse grained Inconel 625 step wedge, and compared to the Total Focusing Method (TFM). Initial results have seen SNR improvements of over 20dB compared to TFM, and a resolution that is much higher.
Reliability and validation of the Dutch Achilles tendon Total Rupture Score.
Opdam, K T M; Zwiers, R; Wiegerinck, J I; Kleipool, A E B; Haverlag, R; Goslings, J C; van Dijk, C N
2018-03-01
Patient-reported outcome measures (PROMs) have become a cornerstone for the evaluation of the effectiveness of treatment. The Achilles tendon Total Rupture Score (ATRS) is a PROM for outcome and assessment of an Achilles tendon rupture. The aim of this study was to translate the ATRS to Dutch and evaluate its reliability and validity in the Dutch population. A forward-backward translation procedure was performed according to the guidelines of cross-cultural adaptation process. The Dutch ATRS was evaluated for reliability and validity in patients treated for a total Achilles tendon rupture from 1 January 2012 to 31 December 2014 in one teaching hospital and one academic hospital. Reliability was assessed by the intraclass correlation coefficients (ICC), Cronbach's alpha and minimal detectable change (MDC). We assessed construct validity by calculation of Spearman's rho correlation coefficient with domains of the Foot and Ankle Outcome Score (FAOS), Victorian Institute of Sports Assessment-Achilles questionnaire (VISA-A) and Numeric Rating Scale (NRS) for pain in rest and during running. The Dutch ATRS had a good test-retest reliability (ICC = 0.852) and a high internal consistency (Cronbach's alpha = 0.96). MDC was 30.2 at individual level and 3.5 at group level. Construct validity was supported by 75 % of the hypothesized correlations. The Dutch ATRS had a strong correlation with NRS for pain during running (r = -0.746) and all the five subscales of the Dutch FAOS (r = 0.724-0.867). There was a moderate correlation with the VISA-A-NL (r = 0.691) and NRS for pain in rest (r = -0.580). The Dutch ATRS shows an adequate reliability and validity and can be used in the Dutch population for measuring the outcome of treatment of a total Achilles tendon rupture and for research purposes. Diagnostic study, Level I.
NASA Astrophysics Data System (ADS)
Folkert, Michael R.; Setton, Jeremy; Apte, Aditya P.; Grkovski, Milan; Young, Robert J.; Schöder, Heiko; Thorstad, Wade L.; Lee, Nancy Y.; Deasy, Joseph O.; Oh, Jung Hun
2017-07-01
In this study, we investigate the use of imaging feature-based outcomes research (‘radiomics’) combined with machine learning techniques to develop robust predictive models for the risk of all-cause mortality (ACM), local failure (LF), and distant metastasis (DM) following definitive chemoradiation therapy (CRT). One hundred seventy four patients with stage III-IV oropharyngeal cancer (OC) treated at our institution with CRT with retrievable pre- and post-treatment 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) scans were identified. From pre-treatment PET scans, 24 representative imaging features of FDG-avid disease regions were extracted. Using machine learning-based feature selection methods, multiparameter logistic regression models were built incorporating clinical factors and imaging features. All model building methods were tested by cross validation to avoid overfitting, and final outcome models were validated on an independent dataset from a collaborating institution. Multiparameter models were statistically significant on 5 fold cross validation with the area under the receiver operating characteristic curve (AUC) = 0.65 (p = 0.004), 0.73 (p = 0.026), and 0.66 (p = 0.015) for ACM, LF, and DM, respectively. The model for LF retained significance on the independent validation cohort with AUC = 0.68 (p = 0.029) whereas the models for ACM and DM did not reach statistical significance, but resulted in comparable predictive power to the 5 fold cross validation with AUC = 0.60 (p = 0.092) and 0.65 (p = 0.062), respectively. In the largest study of its kind to date, predictive features including increasing metabolic tumor volume, increasing image heterogeneity, and increasing tumor surface irregularity significantly correlated to mortality, LF, and DM on 5 fold cross validation in a relatively uniform single-institution cohort. The LF model also retained significance in an independent population.
Validation of the Fibromyalgia Survey Questionnaire within a Cross-Sectional Survey
Häuser, Winfried; Jung, Eva; Erbslöh-Möller, Brigitte; Gesmann, Mechthild; Kühn-Becker, Hedi; Petermann, Franz; Langhorst, Jost; Weiss, Thomas; Winkelmann, Andreas; Wolfe, Frederick
2012-01-01
The Fibromyalgia Survey Questionnaire (FSQ) assesses the key symptoms of fibromyalgia syndrome. The FSQ can be administrated in survey research and settings where the use of interviews to evaluate the number of pain sites and extent of somatic symptom intensity and tender point examination would be difficult. We validated the FSQ in a cross-sectional survey with FMS patients. In a cross-sectional survey, participants with physician diagnosis of FMS were recruited by FMS-self help organisations and nine clinical institutions of different levels of care. Participants answered the FSQ (composed by the Widespread Pain Index [WPI] and the Somatic Severity Score [SSS]) assessing the Fibromyalgia Survey Diagnostic Criteria (FSDC) and the Patient Health Questionnaire PHQ 4. American College of Rheumatology 1990 classification criteria were assessed in a subgroup of participants. 1,651 persons diagnosed with FMS were included into analysis. The acceptance of the FSQ-items ranged between 78.9 to 98.1% completed items. The internal consistency of the items of the SSS ranged between 0.75–0.82. 85.5% of the study participants met the FSDC. The concordance rate of the FSDC and ACR 1990 criteria was 72.7% in a subsample of 128 patients. The Pearson correlation of the SSS with the PHQ 4 depression score was 0.52 (p<0.0001) and with the PHQ anxiety score was 0.51 (p<0.0001) (convergent validity). 64/202 (31.7%) of the participants not meeting the FSDC criteria and 152/1283 (11.8%) of the participants meeting the FSDC criteria reported an improvement (slightly too very much better) in their health status since FMS-diagnosis (Chi2 = 55, p<0.0001) (discriminant validity). The study demonstrated the feasibility of the FSQ in a cross-sectional survey with FMS-patients. The reliability, convergent and discriminant validity of the FSQ were good. Further validation studies of the FSQ in clinical and general population settings are necessary. PMID:22662163
Estimating energy expenditure from heart rate in older adults: a case for calibration.
Schrack, Jennifer A; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M; Ferrucci, Luigi
2014-01-01
Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using different levels of calibration. Heart rate and energy expenditure were assessed across five levels of exertion in 290 adults participating in the Baltimore Longitudinal Study of Aging. Correlation and random effects regression analyses assessed the linearity of the relationship between heart rate and energy expenditure and cross-validation models assessed predictive performance. Heart rate and energy expenditure were highly correlated (r=0.98) and linear regardless of age or sex. Intra-person variability was low but inter-person variability was high, with substantial heterogeneity of the random intercept (s.d. =0.372) despite similar slopes. Cross-validation models indicated individual calibration data substantially improves accuracy predictions of energy expenditure from heart rate, reducing the potential for considerable measurement bias. Although using five calibration measures provided the greatest reduction in the standard deviation of prediction errors (1.08 kcals/min), substantial improvement was also noted with two (0.75 kcals/min). These findings indicate standard regression equations may be used to make population-level inferences when estimating energy expenditure from heart rate in older adults but caution should be exercised when making inferences at the individual level without proper calibration.
French translation and validation of the "Anterior Knee Pain Scale" (AKPS).
Buckinx, F; Bornheim, S; Remy, G; Van Beveren, J; Reginster, Jy; Bruyère, O; Dardenne, N; Kaux, J F
2017-12-21
To linguistically and cross-culturally translate the Anterior Knee Pain Scale into French and to evaluate the reliability and validity of this translated version of the questionnaire. The translation part was performed in six stages, according to international guidelines: (i) two initial translations from English to French; (ii) synthesis of the two translations; (iii) backward translations into the original language; (iv) expert committee to compare the backward translations with the original questionnaire; (v) pre-final version testing and (VI) expert committee appraisal. To validate the French version of the Anterior Knee Pain Scale, we assessed its validity, reliability and floor/ceiling effects. To do this, volunteer patients from the French part of Belgium and from France, with patellofemoral pain were asked to answer the French version of the Anterior Knee Pain Scale at baseline and after 7 days, as well as the generic SF-36 questionnaire. The Anterior Knee Pain Scale was translated without any major difficulties. A total of 101 subjects aged 34.5 ± 11.4 years (58.4% of women) were included in this study. Results indicated an excellent test-retest reliability (Intra-class correlation coefficient (ICC) = 0.97, 95%CI: 0.96-0.98), a high internal consistency (Cronbach's alpha = 0.87), a consistent construct validity (high correlations with the SF-36 questionnaire were found with domains related to physical function (r = 0.80), physical role (r = 0.70) and pain (r = 0.64)) and low or moderate correlations with domains related to mental health (r = 0.26), vitality (r = 0.32) and social function (r = 0.41). Moreover, no floor/ceiling effects have been found. A valid French version of the Anterior Knee Pain Scale is now available and can be used with confidence to better assess the disease burden associated with patellofemoral pain. It was successfully cross-culturally adapted into French. Implications for rehabilitation The results on psychometric properties of the French Anterior Knee Pain Scale are comparable with six validated versions obtained for the Finnish, the Turkish, the Chinese, the Dutch, the Thai and the Persian populations. The French translated version of the Anterior Knee Pain Scale is a reliable and valid instrument for assessing the functional limitations associated with patellofemoral pain. The test-retest reliability of the French Anterior Knee Pain Scale was excellent, the internal consistency was high and the construct validity was consistent. There were no floor/ceiling effects.
Ballangrud, Randi; Husebø, Sissel Eikeland; Hall-Lord, Marie Louise
2017-12-02
Teamwork is an integrated part of today's specialized and complex healthcare and essential to patient safety, and is considered as a core competency to improve twenty-first century healthcare. Teamwork measurements and evaluations show promising results to promote good team performance, and are recommended for identifying areas for improvement. The validated TeamSTEPPS® Teamwork Perception Questionnaire (T-TPQ) was found suitable for cross-cultural validation and testing in a Norwegian context. T-TPQ is a self-report survey that examines five dimensions of perception of teamwork within healthcare settings. The aim of the study was to translate and cross-validate the T-TPQ into Norwegian, and test the questionnaire for psychometric properties among healthcare personnel. The T-TPQ was translated and adapted to a Norwegian context according to a model of a back-translation process. A total of 247 healthcare personnel representing different professionals and hospital settings responded to the questionnaire. A confirmatory factor analysis was carried out to test the factor structure. Cronbach's alpha was used to establish internal consistency, and an Intraclass Correlation Coefficient was used to assess the test - retest reliability. A confirmatory factor analysis showed an acceptable fitting model (χ 2 (df) 969.46 (546), p < 0.001, Root Mean Square Error of Approximation (RMSEA) = 0.056, Tucker-Lewis Index (TLI) = 0.88, Comparative fit index (CFI) = 0.89, which indicates that each set of the items that was supposed to accompany each teamwork dimension clearly represents that specific construct. The Cronbach's alpha demonstrated acceptable values on the five subscales (0.786-0.844), and test-retest showed a reliability parameter, with Intraclass Correlation Coefficient scores from 0.672 to 0.852. The Norwegian version of T-TPQ was considered to be acceptable regarding the validity and reliability for measuring Norwegian individual healthcare personnel's perception of group level teamwork within their unit. However, it needs to be further tested, preferably in a larger sample and in different clinical settings.
Iglesias-Parra, Maria Rosa; García-Guerrero, Alfonso; García-Mayor, Silvia; Kaknani-Uttumchandani, Shakira; León-Campos, Álvaro; Morales-Asencio, José Miguel
2015-07-01
To develop an evaluation system of clinical competencies for the practicum of nursing students based on the Nursing Interventions Classification (NIC). Psychometric validation study: the first two phases addressed definition and content validation, and the third phase consisted of a cross-sectional study for analyzing reliability. The study population was undergraduate nursing students and clinical tutors. Through the Delphi technique, 26 competencies and 91 interventions were isolated. Cronbach's α was 0.96. Factor analysis yielded 18 factors that explained 68.82% of the variance. Overall inter-item correlation was 0.26, and total-item correlation ranged between 0.66 and 0.19. A competency system for the nursing practicum, structured on the NIC, is a reliable method for assessing and evaluating clinical competencies. Further evaluations in other contexts are needed. The availability of standardized language systems in the nursing discipline supposes an ideal framework to develop the nursing curricula. © 2015 Sigma Theta Tau International.
Roalf, David R; Moore, Tyler M; Wolk, David A; Arnold, Steven E; Mechanic-Hamilton, Dawn; Rick, Jacqueline; Kabadi, Sushila; Ruparel, Kosha; Chen-Plotkin, Alice S; Chahine, Lama M; Dahodwala, Nabila A; Duda, John E; Weintraub, Daniel A; Moberg, Paul J
2016-01-01
Introduction Screening for cognitive deficits is essential in neurodegenerative disease. Screening tests, such as the Montreal Cognitive Assessment (MoCA), are easily administered, correlate with neuropsychological performance and demonstrate diagnostic utility. Yet, administration time is too long for many clinical settings. Methods Item response theory and computerised adaptive testing simulation were employed to establish an abbreviated MoCA in 1850 well-characterised community-dwelling individuals with and without neurodegenerative disease. Results 8 MoCA items with high item discrimination and appropriate difficulty were identified for use in a short form (s-MoCA). The s-MoCA was highly correlated with the original MoCA, showed robust diagnostic classification and cross-validation procedures substantiated these items. Discussion Early detection of cognitive impairment is an important clinical and public health concern, but administration of screening measures is limited by time constraints in demanding clinical settings. Here, we provide as-MoCA that is valid across neurological disorders and can be administered in approximately 5 min. PMID:27071646
Martínez-Sánchez, José M; González-Marrón, Adrián; Martín-Sánchez, Juan Carlos; Sureda, Xisca; Fu, Marcela; Pérez-Ortuño, Raúl; Lidón-Moyano, Cristina; Galán, Iñaki; Pascual, José Antonio; Fernández, Esteve
2017-11-02
The objective of this study was to assess the validity of two questions about the perception of intensity of exposure to secondhand smoke (SHS) at home using as a reference environmental markers (airborne nicotine and benzene) and biomarkers of exposure (cotinine in saliva and urine). This was a cross-sectional study in a convenience sample of 49 non-smoking volunteers. We found a high correlation between self-reported SHS exposure and airborne nicotine (r sp =0.806, p<0.05), salivary cotinine (r sp =0.752, p<0.05), and urinary cotinine (r sp =0.626, p<0.05). We did not find differences between the score question and the conventional ones (p >0.05). In conclusion, the significant correlation of the two questions proposed with environmental markers and personal markers indicates their potential validity to assess exposure to SHS at home. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.
Qin, Li-Tang; Liu, Shu-Shen; Liu, Hai-Ling
2010-02-01
A five-variable model (model M2) was developed for the bioconcentration factors (BCFs) of nonpolar organic compounds (NPOCs) by using molecular electronegativity distance vector (MEDV) to characterize the structures of NPOCs and variable selection and modeling based on prediction (VSMP) to select the optimum descriptors. The estimated correlation coefficient (r (2)) and the leave-one-out cross-validation correlation coefficients (q (2)) of model M2 were 0.9271 and 0.9171, respectively. The model was externally validated by splitting the whole data set into a representative training set of 85 chemicals and a validation set of 29 chemicals. The results show that the main structural factors influencing the BCFs of NPOCs are -cCc, cCcc, -Cl, and -Br (where "-" refers to a single bond and "c" refers to a conjugated bond). The quantitative structure-property relationship (QSPR) model can effectively predict the BCFs of NPOCs, and the predictions of the model can also extend the current BCF database of experimental values.
Cross-cultural adaptation and validation to Brazil of the Obesity-related Problems Scale.
Brasil, Andreia Mara Brolezzi; Brasil, Fábio; Maurício, Angélica Aparecida; Vilela, Regina Maria
2017-01-01
To validate a reliable version of the Obesity-related Problems Scale in Portuguese to use it in Brazil. The Obesity-related Problems Scale was translated and transculturally adapted. Later it was simultaneously self-applied with a 12-item version of the World Health Organization Disability Assessment Schedule 2.0 (WHODAS 2.0), to 50 obese patients and 50 non-obese individuals, and applied again to half of them after 14 days. The Obesity-related Problems scale was able to differentiate obese from non-obese individuals with higher accuracy than WHODAS 2.0, correlating with this scale and with body mass index. The factor analysis determined a two-dimensional structure, which was confirmed with χ2/df=1.81, SRMR=0.05, and CFI=0.97. The general a coefficient was 0.90 and the inter-item intra-class correlation, in the reapplication, ranged from 0.75 to 0.87. The scale proved to be valid and reliable for use in the Brazilian population, without the need to exclude items.
Validation and reliability of a Behcet’s Syndrome Activity Scale in Korea
Choi, Hyo Jin; Seo, Mi Ryoung; Ryu, Hee Jung; Baek, Han Joo
2016-01-01
Background/Aims: We prepared a cross-cultural adaptation of the Behcet’s Syndrome Activity Scale (BSAS) and evaluated its reliability and validity in Korea. Methods: Fifty patients with Behcet’s disease (BD) who attended the Rheumatology Clinic of Gachon University Gil Medical Center were included in this study. The first BSAS questionnaire was administered at each clinic visit, and the second questionnaire was completed at home within 24 hours of the visit. A Behcet’s Disease Current Activity Form (BDCAF) and a Behcet’s Disease Quality of Life (BDQOL) form were also given to patients. The test-retest reliability was analyzed by intraclass correlation coefficients (ICC). To assess the validity, the total BSAS score was compared with the BDCAF score, the patient/physician global assessment, and the BDQOL by Spearman rank correlation. Results: Twelve males and 38 females were enrolled. The mean age was 48.5 years and the mean disease duration was 6.7 years. Thirty-eight patients (76.0%) returned the questionnaire by mail. For the test-retest reliability, the two assessments were significantly correlated on all 10 items of the BSAS questionnaire (p < 0.05) and the total BSAS score (ICC, 0.925; p < 0.001). The total BSAS score was statistically correlated with the BDQOL, BDCAF, and patient/physician global assessment (p < 0.01). Conclusions: The Korean version of BSAS is a reliable and valid instrument to measure BD activity. PMID:26767871
Tong, W W; Wang, W; Xu, W D
2016-08-15
The Western Ontario Meniscal Evaluation Tool (WOMET) is a questionnaire designed to evaluate the health-related quality of life (HRQOL) of patients with meniscal pathology. Our study aims to culturally adapt and validate the WOMET into a Chinese version. We translated the WOMET into Chinese. Then, a total of 121 patients with meniscal pathology were invited to participate in this study. To assess the test-retest reliability, the Chinese version WOMET was completed twice at 7-day intervals by the participants. The construct validity was assessed using Pearson's correlation coefficient or Spearman's correlation to test for correlations among the Chinese version WOMET and the eight domains of Short Form-36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the International Knee Documentation Committee (IKDC) score. Responsiveness was tested by comparison of the preoperative and postoperative scores of the Chinese version WOMET. The test-retest reliability of the overall scale and different domains were all found to be excellent. The Cronbach's α was 0.90. The Chinese version WOMET correlated well with other questionnaires which suggested good construct validity. We observed no ceiling and floor effects of the Chinese version WOMET. We also found good responsiveness for the effect size, and the standardized response mean values were 0.86 and 1.11. The Chinese version of the WOMET appears to be reliable and valid in evaluating patients with meniscal pathology.
Aloba, Olutayo; Ajao, Olayinka; Alimi, Taiwo; Esan, Olufemi
2016-01-01
Objectives: To examine the construct and correlates of hopelessness among family caregivers of Nigerian psychiatric patients. Materials and Methods: This is a cross-sectional, descriptive study involving 264 family caregiver-patients’ dyads recruited from two university teaching hospitals psychiatric clinics in Southwestern Nigeria. Results: Exploratory factor analysis revealed a two-factor 9-item model of the Beck Hopelessness Scale (BHS) among the family caregivers. Confirmatory factor analysis of the model revealed satisfactory indices of fitness (goodness of fit index = 0.97, comparative fit index = 0.96, Chi-square/degree of freedom (CMIN/DF) = 1.60, root mean square error of approximation = 0.048, expected cross-validation index = 0.307, and standardized root mean residual = 0.005). Reliability of the scale was modestly satisfactory (Cronbach's alpha 0.72). Construct validity of scale was supported by significant correlations with the family caregivers’ scores on the Zarit Burden Interview, mini international neuropsychiatric interview suicidality module, General Health Questionnaire-12 (GHQ-12), and Patient Health Questionnaire-9. The greatest variance in the family caregivers’ scores on the BHS was contributed by their scores on the psychological distress scale (GHQ-12). Conclusions: The BHS has adequate psychometric properties among Nigerian psychiatric patients’ family caregivers. There is the need to pay attention to the psychological well-being of the family caregivers of Nigerian psychiatric patients. PMID:28163498
Cross-Cultural Validity of the Ruminative Responses Scale in Argentina and the United States.
Arana, Fernán G; Rice, Kenneth G
2017-09-01
Although frequently used in the United States, the Ruminative Response Scale (RRS) has not been extensively studied in cross-cultural samples. The present study evaluated the factor structure of Treynor et al.'s 10-item version of the RRS in samples from Argentina ( N = 308) and the United States ( N = 371). In addition to testing measurement invariance between the countries, we evaluated whether the maladaptive implications of rumination were weaker for the Argentinians than for the U.S. group. Self-critical perfectionism was the criterion in those tests. Partial scalar invariance supported an 8-item version of the RRS. There were no differences in factor means or factor correlations in RRS dimensions between countries. Brooding and Reflection were positively correlated with self-critical perfectionism in both countries, with no significant differences in the sizes of these relations between the two samples. Results are discussed in terms of psychometric and cross-cultural implications for rumination.
Haidar, Rachid K; Kassak, Kassem; Masrouha, Karim; Ibrahim, Kamal; Mhaidli, Hani
2015-09-01
Cross-sectional validation and reliability assessment study of Arabic version of Scoliosis Research Society-22 (SRS-22r) Questionnaire. To develop and validate the Arabic version of the SRS-22r questionnaire. The diagnosis and treatment of adolescent idiopathic scoliosis may influence patient quality of life. SRS-22r is an internationally validated questionnaire used to assess function/activity, pain, self-image, and mental health of patients with scoliosis. It has been translated into several languages but not into Arabic language. Therefore, a valid health-related quality-of-life outcome questionnaire for patients with spinal deformity is still lacking in Arabic language. The English version of SRS-22r questionnaire was translated, back-translated, and culturally adapted to Arabic language. Then, 81 patients with idiopathic adolescent scoliosis were allocated randomly into either the reliability testing group (group 1) or the validity testing group (group 2). Group 1 patients completed Arabic version of SRS-22r questionnaire twice with 1-week interval in-between. Cronbach α and intraclass correlation coefficient were measured to determine internal consistency and temporal reliability. Group 2 patients completed the Arabic version of SRS-22r questionnaire and the previously validated Arabic version of 36-Item Short Form Health Survey (Short Form-36) questionnaire concurrently, and Pearson correlation coefficient was obtained to assess validity. Content analysis, internal consistency reliability, test/retest reproducibility (intraclass correlation coefficient range: 0.82-0.90), and test of concurrent validity showed satisfactory results. Function/activity and satisfaction with management domains had a lower Cronbach α (0.58 and 0.44, respectively, vs. 0.71-0.85 range for others). Self-image/appearance and satisfaction with management had a lower correlation with domains of the 36-Item Short Form Health Survey. An Arabic version of the SRS-22r questionnaire has been developed and validated. This questionnaire will aid health care workers and researchers in evaluation of patient perception of the deformity, satisfaction with treatment, and quality of life in Arabic-speaking populations. 3.
Puhan, Milo A; Gaspoz, Jean-Michel; Bridevaux, Pierre-Olivier; Schindler, Christian; Ackermann-Liebrich, Ursula; Rochat, Thierry; Gerbase, Margaret W
2008-02-15
Few epidemiologic studies have assessed health-related quality of life (HRQL) of asthma patients from a general population and it is unclear which instrument is best suitable for this purpose. We investigated the validity of the Asthma Quality of Life Questionnaire (AQLQ) and the SF-36 completed by individuals with asthma from the population-based SAPALDIA (Swiss study on air pollution and lung diseases in adults) cohort. The study included 258 participants with a physician-diagnosed asthma who had completed the AQLQ and SF-36. We assessed floor and ceiling effects, internal consistency reliability and cross-sectional validity with a priori hypotheses that correlations between the specific HRQL domains (e.g. "symptoms" or "physical functioning") and the corresponding external validation measures (respiratory symptoms, need for doctor visits, limitation in activities due to asthma and lung function) would capture similar aspects and be correlated moderately (> or = 0.3) to strongly (> or = 0.5), whereas non-corresponding domains be correlated weakly with each other (<0.3). The AQLQ showed pronounced ceiling effects with all median domain scores above 6 (scores varied from 1-7). For the SF-36, ceiling effects were present in 5 out of 8 domains. Cronbach's alpha was >0.7 for all AQLQ and SF-36 domains. Correlations between the AQLQ domains "respiratory symptoms", "activity limitation" and "environmental exposure", and the validation measures ranged from 0.29-0.57. Correlations between the "emotional function" domain and the validation measures were also in this range (0.31-0.55) and not as low as we hypothesized. For the SF-36, correlations between "physical functioning" and "role physical", and the validation measures ranged from 0.25-0.56, whereas "role emotional" and "mental health" correlated with these measures from 0.01-0.23. The AQLQ and the SF-36 showed fairly good internal consistency. Both instruments are limited by ceiling effects, but they appear less pronounced in the SF-36, which also shows a better discrimination between different aspects of HRQL. The SF-36 may therefore be a more valid measure of HRQL than the AQLQ when applied to individuals with asthma from the general population.
NASA Astrophysics Data System (ADS)
Li, Wenlian; Si, Hongzong; Li, Yang; Ge, Cuizhu; Song, Fucheng; Ma, Xiuting; Duan, Yunbo; Zhai, Honglin
2016-08-01
Viral hepatitis C infection is one of the main causes of the hepatitis after blood transfusion and hepatitis C virus (HCV) infection is a global health threat. The HCV NS5B polymerase, an RNA dependent RNA polymerase (RdRp) and an essential role in the replication of the virus, has no functional equivalent in mammalian cells. So the research and development of efficient NS5B polymerase inhibitors provides a great strategy for antiviral therapy against HCV. A combined three-dimensional quantitative structure-activity relationship (QSAR) modeling was accomplished to profoundly understand the structure-activity correlation of a train of indole-based inhibitors of the HCV NS5B polymerase to against HCV. A comparative molecular similarity indices analysis (COMSIA) model as the foundation of the maximum common substructure alignment was developed. The optimum model exhibited statistically significant results: the cross-validated correlation coefficient q2 was 0.627 and non-cross-validated r2 value was 0.943. In addition, the results of internal validations of bootstrapping and Y-randomization confirmed the rationality and good predictive ability of the model, as well as external validation (the external predictive correlation coefficient rext2 = 0.629). The information obtained from the COMSIA contour maps enables the interpretation of their structure-activity relationship. Furthermore, the molecular docking study of the compounds for 3TYV as the protein target revealed important interactions between active compounds and amino acids, and several new potential inhibitors with higher activity predicted were designed basis on our analyses and supported by the simulation of molecular docking. Meanwhile, the OSIRIS Property Explorer was introduced to help select more satisfactory compounds. The satisfactory results from this study may lay a reliable theoretical base for drug development of hepatitis C virus NS5B polymerase inhibitors.
Wo, Su Woan; Lai, Pauline Siew Mei; Ong, Lai Choo; Low, Wah Yun; Lim, Kheng Seang; Tay, Chee Giap; Wong, Chee Piau; Ranjini, Sivanesom
2015-04-01
We aimed to cross-culturally adapt the parent-proxy Health-Related Quality of Life Measure for Children with Epilepsy (CHEQOL-25) into Malay and to determine its validity and reliability among parents of children with epilepsy in Malaysia. The English version of the parent-proxy CHEQOL-25 was translated according to international guidelines to Malay. Content validity was verified by an expert panel and piloted in five parents of children with epilepsy (CWE). The Malay parent-proxy CHEQOL-25 was then administered to 40 parents of CWE, aged 8-18years from two tertiary hospitals, at baseline and 2weeks later. Parents were also required to complete the Malay PedsQL™ 4.0 so that convergent validity could be assessed. Hypothesis testing was assessed by correlating the individual subscales in the parent-proxy CHEQOL-25 with epilepsy severity, the number of anticonvulsants, and the number of close friends. Participants from the pilot study did not encounter any problems in answering the final translated Malay parent-proxy CHEQOL-25. Hence, no further modifications were made. Cronbach's α for each subscale of the Malay parent-proxy CHEQOL-25 ranged from 0.67 to 0.83. The intraclass correlation coefficient for all items at test-retest ranged from 0.70 to 0.94. Both the CHEQOL-25 and the PedsQL™ 4.0 showed good correlation in the social and emotional subscales (r=0.598, p=0.002 and r=0.342, p=0.031, respectively). The severity of epilepsy, higher number of antiepileptic drug(s), poorer cognitive ability of the child, lower number of close friends, and lesser amount of time spent with friends were significantly associated with poorer health-related quality of life. The Malay parent-proxy CHEQOL-25 was found to be a valid and reliable instrument to assess parents' perceived HRQOL of their CWE in Malaysia. Copyright © 2015 Elsevier Inc. All rights reserved.
Ibrahim, Ahmed K; Kelly, Shona J; Challenor, Emily C; Glazebrook, Cris
2010-12-10
It is thought that depressive disorders will be the second leading cause of disability worldwide by 2020. Recently, there is a steady increase in the number of university students diagnosed and treated as depression patients. It can be assumed that depression is a serious mental health problem for university students because it affects all age groups of the students either younger or older equally. The current study aims to establish the reliability and validity of the Zagazig Depression scale in a UK sample. The study was a cross-sectional online survey. A sample of 133 out of 275 undergraduate students from a range of UK Universities in the academic year 2008-2009, aged 20.3 ± 6.3 years old were recruited. A modified back translated version of Zagazig Depression scale was used. In order to validate the Zagazig Depression scale, participants were asked to complete the Patient Health Questionnaire. Statistical analysis includes Kappa analysis, Cronbach's alpha, Spearman's correlation analysis, and Confirmatory Factor analysis. Using the recommended cut-off of Zagazig Depression scale for possible minor depression it was found that 30.3% of the students have depression and higher percentage was identified according to the Patient Health Questionnaire (37.4%). Females were more depressed. The mean ZDS score was 8.3 ± 4.2. Rates of depression increase as students get older. The reliability of The ZDS was satisfactory (Cronbach's alpha was .894). For validity, ZDS score was strongly associated with PHQ, with no significant difference (p-value > 0.05), with strong positive correlation (r = +.8, p-value < 0.01). The strong, significant correlation between the PHQ and ZDS, along with high internal consistency of the ZDS as a whole provides evidence that ZDS is a reliable measure of depressive symptoms and is promising for the use of the translated ZDS in a large-scale cross-culture study.
Erhart, M; Hagquist, C; Auquier, P; Rajmil, L; Power, M; Ravens-Sieberer, U
2010-07-01
This study compares item reduction analysis based on classical test theory (maximizing Cronbach's alpha - approach A), with analysis based on the Rasch Partial Credit Model item-fit (approach B), as applied to children and adolescents' health-related quality of life (HRQoL) items. The reliability and structural, cross-cultural and known-group validity of the measures were examined. Within the European KIDSCREEN project, 3019 children and adolescents (8-18 years) from seven European countries answered 19 HRQoL items of the Physical Well-being dimension of a preliminary KIDSCREEN instrument. The Cronbach's alpha and corrected item total correlation (approach A) were compared with infit mean squares and the Q-index item-fit derived according to a partial credit model (approach B). Cross-cultural differential item functioning (DIF ordinal logistic regression approach), structural validity (confirmatory factor analysis and residual correlation) and relative validity (RV) for socio-demographic and health-related factors were calculated for approaches (A) and (B). Approach (A) led to the retention of 13 items, compared with 11 items with approach (B). The item overlap was 69% for (A) and 78% for (B). The correlation coefficient of the summated ratings was 0.93. The Cronbach's alpha was similar for both versions [0.86 (A); 0.85 (B)]. Both approaches selected some items that are not strictly unidimensional and items displaying DIF. RV ratios favoured (A) with regard to socio-demographic aspects. Approach (B) was superior in RV with regard to health-related aspects. Both types of item reduction analysis should be accompanied by additional analyses. Neither of the two approaches was universally superior with regard to cultural, structural and known-group validity. However, the results support the usability of the Rasch method for developing new HRQoL measures for children and adolescents.
NASA Astrophysics Data System (ADS)
Pouyandeh, Sima; Iubini, Stefano; Jurinovich, Sandro; Omar, Yasser; Mennucci, Benedetta; Piazza, Francesco
2017-12-01
In this paper, we work out a parameterization of environmental noise within the Haken-Strobl-Reinenker (HSR) model for the PE545 light-harvesting complex, based on atomic-level quantum mechanics/molecular mechanics (QM/MM) simulations. We use this approach to investigate the role of various auto- and cross-correlations in the HSR noise tensor, confirming that site-energy autocorrelations (pure dephasing) terms dominate the noise-induced exciton mobility enhancement, followed by site energy-coupling cross-correlations for specific triplets of pigments. Interestingly, several cross-correlations of the latter kind, together with coupling-coupling cross-correlations, display clear low-frequency signatures in their spectral densities in the 30-70 cm-1 region. These slow components lie at the limits of validity of the HSR approach, which requires that environmental fluctuations be faster than typical exciton transfer time scales. We show that a simple coarse-grained elastic-network-model (ENM) analysis of the PE545 protein naturally spotlights collective normal modes in this frequency range that represent specific concerted motions of the subnetwork of cysteines covalenty linked to the pigments. This analysis strongly suggests that protein scaffolds in light-harvesting complexes are able to express specific collective, low-frequency normal modes providing a fold-rooted blueprint of exciton transport pathways. We speculate that ENM-based mixed quantum classical methods, such as Ehrenfest dynamics, might be promising tools to disentangle the fundamental designing principles of these dynamical processes in natural and artificial light-harvesting structures.
Sound quality indicators for urban places in Paris cross-validated by Milan data.
Ricciardi, Paola; Delaitre, Pauline; Lavandier, Catherine; Torchia, Francesca; Aumond, Pierre
2015-10-01
A specific smartphone application was developed to collect perceptive and acoustic data in Paris. About 3400 questionnaires were analyzed, regarding the global sound environment characterization, the perceived loudness of some emergent sources and the presence time ratio of sources that do not emerge from the background. Sound pressure level was recorded each second from the mobile phone's microphone during a 10-min period. The aim of this study is to propose indicators of urban sound quality based on linear regressions with perceptive variables. A cross validation of the quality models extracted from Paris data was carried out by conducting the same survey in Milan. The proposed sound quality general model is correlated with the real perceived sound quality (72%). Another model without visual amenity and familiarity is 58% correlated with perceived sound quality. In order to improve the sound quality indicator, a site classification was performed by Kohonen's Artificial Neural Network algorithm, and seven specific class models were developed. These specific models attribute more importance on source events and are slightly closer to the individual data than the global model. In general, the Parisian models underestimate the sound quality of Milan environments assessed by Italian people.
Wolf, Kathrin; Cyrys, Josef; Harciníková, Tatiana; Gu, Jianwei; Kusch, Thomas; Hampel, Regina; Schneider, Alexandra; Peters, Annette
2017-02-01
Important health relevance has been suggested for ultrafine particles (UFP) and ozone, but studies on long-term effects are scarce, mainly due to the lack of appropriate spatial exposure models. We designed a measurement campaign to develop land use regression (LUR) models to predict the spatial variability focusing on particle number concentration (PNC) as indicator for UFP, ozone and several other air pollutants in the Augsburg region, Southern Germany. Three bi-weekly measurements of PNC, ozone, particulate matter (PM 10 , PM 2.5 ), soot (PM 2.5 abs) and nitrogen oxides (NO x , NO 2 ) were performed at 20 sites in 2014/15. Annual average concentration were calculated and temporally adjusted by measurements from a continuous background station. As geographic predictors we offered several traffic and land use variables, altitude, population and building density. Models were validated using leave-one-out cross-validation. Adjusted model explained variance (R 2 ) was high for PNC and ozone (0.89 and 0.88). Cross-validation adjusted R 2 was slightly lower (0.82 and 0.81) but still indicated a very good fit. LUR models for other pollutants performed well with adjusted R 2 between 0.68 (PM coarse ) and 0.94 (NO 2 ). Contrary to previous studies, ozone showed a moderate correlation with NO 2 (Pearson's r=-0.26). PNC was moderately correlated with ozone and PM 2.5 , but highly correlated with NO x (r=0.91). For PNC and NO x , LUR models comprised similar predictors and future epidemiological analyses evaluating health effects need to consider these similarities. Copyright © 2016 Elsevier B.V. All rights reserved.
Corona, Katia; Cerciello, Simone; Morris, Brent Joseph; Visonà, Enrico; Merolla, Giovanni; Porcellini, Giuseppe
2016-12-01
The Western Ontario Osteoarthritis of the Shoulder index (WOOS) has been introduced as a disease-specific quality of life measurement in patients with glenohumeral arthritis. The aim of the present study was to perform a cross-cultural adaptation of the English version of the WOOS to Italian and to assess its validity, reliability and responsiveness in patients with glenohumeral joint osteoarthritis treated conservatively. The adaptation process was carried out following the simplified Guillemin criteria. The English version was translated into Italian by two bilingual orthopaedic surgeons and then translated back into English by two different bilingual orthopaedic surgeons. The original version was compared with the back-translation. The questionnaire was prospectively administered to 30 patients with glenohumeral osteoarthritis at baseline and again after 5 days for retest reliability. After 6 months of conservative treatment, the responsiveness of the questionnaire was assessed in a subsample of 20 patients. The level of statistical significance was set at 0.05. The interclass correlation coefficient between test and retest of the WOOS was 0.99 (P < 0.001). Pearson's correlation coefficient between the WOOS and disability of the arm, shoulder and hand (DASH) preoperatively was 0.73 (P < 0.01) and the correlation between the changes of score for the WOOS and DASH was 0.75 (P < 0.01). There were no floor or ceiling effects. Responsiveness, calculated by standardized response mean, was 1.1 and effect size was 1.3. The Italian version of the WOOS questionnaire has shown to be equivalent to its English version and demonstrated good validity, reliability and responsiveness to conservative treatment of glenohumeral osteoarthritis. Level II.
Bergeron, Lise; Berthiaume, Claude; St-Georges, Marie; Piché, Geneviève; Smolla, Nicole
2013-08-01
As no single informant can be considered the gold standard of child psychopathology, interviewing of children regarding their own symptoms is necessary. Our study focused on the reliability, validity, and clinical use of the Dominic Interactive (DI), a multimedia self-report screen to assess symptoms for the most frequent Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision, mental disorders in school-aged children. A sample of 585 children aged 6 to 11 years from the community and psychiatric clinics was used to analyze the internal consistency, the test-retest estimate of reliability, and the criterion-related validity of the DI against the referral status. In addition, cross-informant correlation coefficients between this instrument (child report) and the Child Symptom Inventory (parent report) were explored in a subsample of 292 participants. For the total sample, Cronbach alpha coefficients ranged from 0.63 to 0.91. Test-retest kappas varied from 0.42 to 0.62 for categories based on cut-off points, except for specific phobias. Intraclass correlation coefficients ranged from 0.70 to 0.81 for symptom scales. The DI discriminated between referred and non-referred children in psychiatric clinics for all symptom scales. Significant cross-informant correlation coefficients were higher for the externalizing symptoms (0.35 to 0.48) than the internalizing symptoms (0.14 to 0.27). Findings of our study reasonably support adequate psychometric properties of the DI. This instrument offers a developmentally sensitive screening method to obtain unique information from young children about their mental health problems in front-line services, psychiatric clinics, and research settings.
Lapa, Teresa A; Carvalho, Sérgio A; Viana, Joaquim S; Ferreira, Pedro L; Pinto-Gouveia, José
2016-11-01
Stress in anaesthesiologists is a common and multifactorial problem related to patients, colleagues and organisations. The consequences of stress include depression, work-home conflicts and burnout. Reduction in stress can be achieved by reducing the number and magnitude of stressors or by increasing resilience strategies. We have created the self-reporting 'Stress Questionnaire in Anaesthesiologists' (SQA), to qualify the sources of stress in anaesthesiologists' professional lives, and measure the level of associated stress. Our study aimed to develop and validate the SQA using exploratory and confirmatory factor analyses. Construct validity was assessed through correlations between SQA and negative psychological outcomes as well as by comparing perception of stress among different known groups. A questionnaire-based cross-sectional, correlational, observational study. The study was conducted between January 2014 and December 2014, throughout different anaesthesia departments in Portuguese hospitals. Data collection was from a representative subset at one specific time point. A sample of 710 anaesthesia specialists and residents from Portugal. The primary outcome measure was to identify specific stressors in anaesthesiologists. Secondary outcome was the association between stressors and burnout, depression symptoms, anxiety, stress, rumination, satisfaction with life and functional impairment. The exploratory analysis showed the SQA is a tri-dimensional instrument and confirmatory analysis showed the tri-dimensional structure presented good model fit. The three dimensions of SQA correlated positively with other stress measures and burnout, but negatively with satisfaction with life. SQA is a well adjusted measure for assessing stressors in anaesthesia physicians and includes clinical, organisational and team stress factors. Results showed that the SQA is a robust and reliable instrument.
Ho, Andy H Y; Potash, Jordan S; Fong, Ted C T; Ho, Vania F L; Chen, Eric Y H; Lau, Robert H W; Au Yeung, Friendly S W; Ho, Rainbow T H
2015-01-01
Stigma of mental illness is a global public health concern, but there lacks a standardized and cross-culturally validated instrument for assessing the complex experience of stigma among people living with mental illness (PLMI) in the Chinese context. This study examines the psychometric properties of a Chinese version of the Stigma Scale (CSS), and explores the relationships between stigma, self-esteem and depression. A cross-sectional survey was conducted with a community sample of 114 Chinese PLMI in Hong Kong. Participants completed the CSS, the Chinese Self-Stigma of Mental Illness Scale, the Chinese Rosenberg Self-Esteem Scale, and the Chinese Patient Health Questionnaire-9. An exploratory factor analysis was conducted to identify the underlying factors of the CSS; concurrent validity assessment was performed via correlation analysis. The original 28-item three-factor structure of the Stigma Scale was found to be a poor fit to the data, whereas a revised 14-item three-factor model provided a good fit with all 14 items loaded significantly onto the original factors: discrimination, disclosure and positive aspects of mental illness. The revised model also displayed moderate to good internal consistency and good construct validity. Further findings revealed that the total stigma scale score and all three of its subscale scores correlated negatively with self-esteem; but only total stigma, discrimination and disclosure correlated positively with depression. The CSS is a short and user-friendly self-administrated questionnaire that proves valuable for understanding the multifaceted stigma experiences among PLMI as well as their impact on psychiatric recovery and community integration in Chinese communities. Copyright © 2014 Elsevier Inc. All rights reserved.
Lamb, B W; Sevdalis, N; Mostafid, H; Vincent, C; Green, J S A
2011-12-01
Teamworking and clinical decision-making are important in multidisciplinary cancer teams (MDTs). Our objective is to assess the quality of information presentation and MDT members' contribution to decision-making via expert observation and self-report, aiming to cross-validate the two methods and assess the insight of MDT members into their own team performance. Behaviors were scored using (i) a validated observational tool employing Likert scales with objective anchors, and (ii) a 29-question online self-report tool. Data were collected from observation of 164 cases in five MDTs, and 47 surveys from MDT members (response rate 70%). Presentation of information (case history, radiological, pathological, comorbidities, psychosocial, and patients' views) and quality of contribution to decision-making of MDT members (surgeons, oncologists, radiologists, pathologists, nurses, and MDT coordinators) were analyzed via descriptive statistics and the Jonckheere-Terpstra test. Correlation between observational and self-report assessments was assessed with Spearman's correlations. Quality of information presentation: Case histories and radiology information rated highest; patients' views and comorbidities/psychosocial issues rated lowest (observed: Z = 14.80, P ≤ 0.001; self-report: Z = 3.70, P < 0.001). Contribution to decision-making: Surgeons and oncologists rated highest, nurses and MDT coordinators rated lowest, and others in between (observed: Z = 20.00, P ≤ 0.001; self-report: Z = 8.10, P < 0.001). Correlations between observational and self-report assessments: Median Spearman's rho = 0.74 (range = 0.66-0.91; P < 0.05). The quality of teamworking and clinical decision-making in MDTs can reliably be assessed using observational and self-report metrics. MDT members have good insight into their own team performance. Such robust assessment methods could provide the basis of a toolkit for MDT team evaluation and improvement.
Xu, Xianghua; Liu, Xiangyu; Ou, Meijun; Xie, Chanjuan; Chen, Yongyi
2018-01-01
Objective: To translate the English work-related acceptance and action questionnaire (WAAQ), make cross-cultural adaptations, and examine its psychometric properties when used by Chinese oncology nurses. Methods: After translation, the psychometric properties of the Chinese WAAQ were analyzed among 417 nurses, and content validity was determined by six experts. Results: Item-level content validity index (CVI) values were between 0.83 and 1.00; scale-level CVI/universal agreement (S-CVI/UA) and S-CVI/average were 0.86 and 0.98, respectively, which implicated a good content validity. The correlation of the Chinese WAAQ with AAQ-II (rs = −0.247, P < 0.001) suggested criterion validity, and those with General Health Questionnaire-12 (−0.250, <0.001) and general self-efficacy scale (0.491, <0.001) and Utrecht work engagement scale (UWES) (0.439, <0.001) suggested convergent validity. Exploratory factor analysis identified a seven-item, one-factor structure of WAAQ. The Chinese version of WAAQ had high internal consistency (Cronbach's α = 0.920), with an item-total correlation coefficient of 0.702–0.828 (P < 0.05), split-half reliability of 0.933, and test-retest reliability of 0.772. Conclusions: The Chinese WAAQ is a reliable and valid tool for assessing psychological flexibility in Chinese oncology nurses. PMID:29379839
Saffari, Mohsen; Naderi, Maryam K; Piper, Crystal N; Koenig, Harold G
There is no valid and well-established tool to measure fatigue in people with chronic hepatitis B. The aim of this study was to translate the Multidimensional Fatigue Inventory (MFI) into Persian and examine its reliability and validity in Iranian people with chronic hepatitis B. The demographic questionnaire and MFI, as well as Chronic Liver Disease Questionnaire and EuroQol-5D (to assess criterion validity), were administered in face-to-face interviews with 297 participants. A forward-backward translation method was used to develop a culturally adapted Persian version of the questionnaire. Cronbach's α was used to assess the internal reliability of the scale. Pearson correlation was used to assess criterion validity, and known-group method was used along with factor analysis to establish construct validity. Cronbach's α for the total scale was 0.89. Convergent and discriminant validities were also established. Correlations between the MFI and the health-related quality of life scales were significant (p < .01). The scale differentiated between subgroups of persons with the hepatitis B infection in terms of age, gender, employment, education, disease duration, and stage of disease. Factor analysis indicated a four-factor solution for the scale that explained 60% of the variance. The MFI is a valid and reliable instrument to identify fatigue in Iranians with hepatitis B.
Gijzel, Sanne M W; van de Leemput, Ingrid A; Scheffer, Marten; Roppolo, Mattia; Olde Rikkert, Marcel G M; Melis, René J F
2017-07-01
We currently still lack valid methods to dynamically measure resilience for stressors before the appearance of adverse health outcomes that hamper well-being. Quantifying an older adult's resilience in an early stage would aid complex decision-making in health care. Translating complex dynamical systems theory to humans, we hypothesized that three dynamical indicators of resilience (variance, temporal autocorrelation, and cross-correlation) in time series of self-rated physical, mental, and social health were associated with frailty levels in older adults. We monitored self-rated physical, mental, and social health during 100 days using daily visual analogue scale questions in 22 institutionalized older adults (mean age 84.0, SD: 5.9 years). Frailty was determined by the Survey of Health, Ageing and Retirement in Europe (SHARE) frailty index. The resilience indicators (variance, temporal autocorrelation, and cross-correlation) were calculated using multilevel models. The self-rated health time series of frail elderly exhibited significantly elevated variance in the physical, mental, and social domain, as well as significantly stronger cross-correlations between all three domains, as compared to the nonfrail group (all P < 0.001). Temporal autocorrelation was not significantly associated with frailty. We found supporting evidence for two out of three hypothesized resilience indicators to be related to frailty levels in older adults. By mirroring the dynamical resilience indicators to a frailty index, we delivered a first empirical base to validate and quantify the construct of systemic resilience in older adults in a dynamic way. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Psychometric Properties of the Persian Translation of the Sexual Quality of Life–Male Questionnaire
Maasoumi, Raziyeh; Mokarami, Hamidreza; Nazifi, Morteza; Stallones, Lorann; Taban, Abrahim; Yazdani Aval, Mohsen; Samimi, Kazem
2016-01-01
Sexual dysfunction has been demonstrated to be related to a poor quality of life. These dysfunctions are especially prevalent among men. This cross-sectional study aimed to investigate the psychometric properties of the Persian translation of the Sexual Quality of Life–Male (SQOL-M), translated and adapted to measure sexual quality of life among Iranian men. Forward–backward procedures were applied in translating the original SQOL-M into Persian, and then the psychometric properties of the Persian translation of the SQOL-M were studied. A total of 181 participants (23-60 years old) were included in the study. Validity was assessed by construct validity using confirmatory factor analysis, convergent validity, and content validity. The international index of erectile function (IIEF) and the work ability index were used to study the convergent validity. Reliability was evaluated through internal consistency and test–retest reliability analyses. The results from confirmatory factor analysis confirmed a one-factor solution for the Persian version of the SQOL-M. Content validity of the translated measure was endorsed by 10 specialists. Pearson correlations indicated that work ability index score, dimensions of the IIEF, and the IIEF total score were positively correlated with the Persian version of the SQOL-M (p < .001). Reliability evaluation indicated a high internal consistency and test–retest reliability. The Cronbach’s alpha coefficient and intraclass correlation coefficients were .96 and .95, respectively. Results indicated that the Persian version of the SQOL-M has good to excellent psychometric properties and can be used to assess the sexual quality of life among Iranian men. PMID:26856758
Psychometric Properties of the Persian Translation of the Sexual Quality of Life-Male Questionnaire.
Maasoumi, Raziyeh; Mokarami, Hamidreza; Nazifi, Morteza; Stallones, Lorann; Taban, Abrahim; Yazdani Aval, Mohsen; Samimi, Kazem
2017-05-01
Sexual dysfunction has been demonstrated to be related to a poor quality of life. These dysfunctions are especially prevalent among men. This cross-sectional study aimed to investigate the psychometric properties of the Persian translation of the Sexual Quality of Life-Male (SQOL-M), translated and adapted to measure sexual quality of life among Iranian men. Forward-backward procedures were applied in translating the original SQOL-M into Persian, and then the psychometric properties of the Persian translation of the SQOL-M were studied. A total of 181 participants (23-60 years old) were included in the study. Validity was assessed by construct validity using confirmatory factor analysis, convergent validity, and content validity. The international index of erectile function (IIEF) and the work ability index were used to study the convergent validity. Reliability was evaluated through internal consistency and test-retest reliability analyses. The results from confirmatory factor analysis confirmed a one-factor solution for the Persian version of the SQOL-M. Content validity of the translated measure was endorsed by 10 specialists. Pearson correlations indicated that work ability index score, dimensions of the IIEF, and the IIEF total score were positively correlated with the Persian version of the SQOL-M ( p < .001). Reliability evaluation indicated a high internal consistency and test-retest reliability. The Cronbach's alpha coefficient and intraclass correlation coefficients were .96 and .95, respectively. Results indicated that the Persian version of the SQOL-M has good to excellent psychometric properties and can be used to assess the sexual quality of life among Iranian men.
Plochg, Thomas; Arah, Onyebuchi A; Botje, Daan; Thompson, Caroline A; Klazinga, Niek S; Wagner, Cordula; Mannion, Russell; Lombarts, Kiki
2014-04-01
Clinical management is hypothesized to be critical for hospital management and hospital performance. The aims of this study were to develop and validate professional involvement scales for measuring the level of clinical management by physicians and nurses in European hospitals. Testing of validity and reliability of scales derived from a questionnaire of 21 items was developed on the basis of a previous study and expert opinion and administered in a cross-sectional seven-country research project 'Deepening our Understanding of Quality improvement in Europe' (DUQuE). A sample of 3386 leading physicians and nurses working in 188 hospitals located in Czech Republic, France, Germany, Poland, Portugal, Spain and Turkey. Validity and reliability of professional involvement scales and subscales. Psychometric analysis yielded four subscales for leading physicians: (i) Administration and budgeting, (ii) Managing medical practice, (iii) Strategic management and (iv) Managing nursing practice. Only the first three factors applied well to the nurses. Cronbach's alpha for internal consistency ranged from 0.74 to 0.86 for the physicians, and from 0.61 to 0.81 for the nurses. Except for the 0.74 correlation between 'Administration and budgeting' and 'Managing medical practice' among physicians, all inter-scale correlations were <0.70 (range 0.43-0.61). Under testing for construct validity, the subscales were positively correlated with 'formal management roles' of physicians and nurses. The professional involvement scales appear to yield reliable and valid data in European hospital settings, but the scale 'Managing medical practice' for nurses needs further exploration. The measurement instrument can be used for international research on clinical management.
Papadopoulou, Soultana L.; Exarchakos, Georgios; Christodoulou, Dimitrios; Theodorou, Stavroula; Beris, Alexandre; Ploumis, Avraam
2016-01-01
Introduction The Ohkuma questionnaire is a validated screening tool originally used to detect dysphagia among patients hospitalized in Japanese nursing facilities. Objective The purpose of this study is to evaluate the reliability and validity of the adapted Greek version of the Ohkuma questionnaire. Methods Following the steps for cross-cultural adaptation, we delivered the validated Ohkuma questionnaire to 70 patients (53 men, 17 women) who were either suffering from dysphagia or not. All of them completed the questionnaire a second time within a month. For all of them, we performed a bedside and VFSS study of dysphagia and asked participants to undergo a second VFSS screening, with the exception of nine individuals. Statistical analysis included measurement of internal consistency with Cronbach's α coefficient, reliability with Cohen's Kappa, Pearson's correlation coefficient and construct validity with categorical components, and One-Way Anova test. Results According to Cronbach's α coefficient (0.976) for total score, there was high internal consistency for the Ohkuma Dysphagia questionnaire. Test-retest reliability (Cohen's Kappa) ranged from 0.586 to 1.00, exhibiting acceptable stability. We also estimated the Pearson's correlation coefficient for the test-retest total score, which reached high levels (0.952; p = 0.000). The One-Way Anova test in the two measurement times showed statistically significant correlation in both measurements (p = 0.02 and p = 0.016). Conclusion The adapted Greek version of the questionnaire is valid and reliable and can be used for the screening of dysphagia in the Greek-speaking patients. PMID:28050209
Papadopoulou, Soultana L; Exarchakos, Georgios; Christodoulou, Dimitrios; Theodorou, Stavroula; Beris, Alexandre; Ploumis, Avraam
2017-01-01
Introduction The Ohkuma questionnaire is a validated screening tool originally used to detect dysphagia among patients hospitalized in Japanese nursing facilities. Objective The purpose of this study is to evaluate the reliability and validity of the adapted Greek version of the Ohkuma questionnaire. Methods Following the steps for cross-cultural adaptation, we delivered the validated Ohkuma questionnaire to 70 patients (53 men, 17 women) who were either suffering from dysphagia or not. All of them completed the questionnaire a second time within a month. For all of them, we performed a bedside and VFSS study of dysphagia and asked participants to undergo a second VFSS screening, with the exception of nine individuals. Statistical analysis included measurement of internal consistency with Cronbach's α coefficient, reliability with Cohen's Kappa, Pearson's correlation coefficient and construct validity with categorical components, and One-Way Anova test. Results According to Cronbach's α coefficient (0.976) for total score, there was high internal consistency for the Ohkuma Dysphagia questionnaire. Test-retest reliability (Cohen's Kappa) ranged from 0.586 to 1.00, exhibiting acceptable stability. We also estimated the Pearson's correlation coefficient for the test-retest total score, which reached high levels (0.952; p = 0.000). The One-Way Anova test in the two measurement times showed statistically significant correlation in both measurements ( p = 0.02 and p = 0.016). Conclusion The adapted Greek version of the questionnaire is valid and reliable and can be used for the screening of dysphagia in the Greek-speaking patients.
Reliability and Validity of Nonradiologic Measures of Forward Flexed Posture in Parkinson Disease.
Nair, Prajakta; Bohannon, Richard W; Devaney, Laurie; Maloney, Catherine; Romano, Alexis
2017-03-01
To examine the intertester reliability and validity of 5 nonradiologic measures of forward flexed posture in individuals with Parkinson disease (PD). Cross-sectional observational study. University outpatient facility and community centers. Individuals (N=28) with PD with Hoehn and Yahr scores of 1 through 4. Not applicable. Occiput to wall status, tragus to wall distance, C7 to wall distance, photographically derived trunk flexion angle, and inclinometric kyphosis measure. Participants were older adults (mean, 69.7±10.6y) with a 14-month to 15-year (mean, 5.9±3.5y) history of PD. Intertester reliability was excellent for all measures (κ=.89 [cued condition] and 1.0 [relaxed condition] for occiput to wall status; intraclass correlation coefficients, .779-.897 for tragus to wall distance, C7 to wall distance, flexion angle, and inclinometric kyphosis measure). Convergent validity was supported for all measures by significant correlations between the same measures obtained during relaxed and cued conditions (eg, occiput to wall relaxed and cued) and for most measures by significant correlations between measures obtained under the same condition (eg, occiput to wall cued and tragus to wall cued). Significant correlations between tragus to wall distance, C7 to wall distance, flexion angle, and inclinometric kyphosis measure and the Unified Parkinson Disease Rating Scale item 28 (posture) also supported convergent validity. Significant differences between tragus to wall distance, C7 to wall distance, and inclinometric kyphosis measure values under relaxed and cued conditions supported known condition validity. Known group validity was demonstrated by significant differences in tragus to wall distance, C7 to wall distance, and inclinometric kyphosis measure obtained from individuals able and individuals unable to touch their occiput to wall when cued to stand tall. Tragus to wall distance, C7 to wall distance, and inclinometric kyphosis measure are reliable and valid nonradiologic measures of forward flexed posture in PD. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Jin, X F; Wang, J; Li, Y J; Liu, J F; Ni, D F
2016-09-20
Objective: To cross-culturally translate the questionnaire of olfactory disorders(QOD)into a simplified Chinese version, and evaluate its reliability and validity in clinical. Method: A simplified Chinese version of the QOD was evaluated in test-retest reliability, split-half reliability and internal consistency.Then it was evaluated in validity test including content validity, criterion-related validity, responsibility. Criterion-related validity was using the medical outcome study's 36-item short rorm health survey(SF-36) and the World Health Organization quality of life-brief (WHOQOL-BREF) for comparison. Result: A total of 239 patients with olfactory dysfunction were enrolled and tested, in which 195 patients completed all three surveys(QOD, SF-36, WHOQOL-BREF). The test-retest reliabilities of the QOD-parosmia statements(QOD-P), QOD-quality of life(QOD-QoL), and the QOD-visual simulation(QOD-VAS)sections were 0.799( P <0.01),0.781( P <0.01),0.488( P <0.01), respectively, and the Cronbach' s α coefficients reliability were 0.477,0.812,0.889,respectively.The split-half reliability of QOD-QoL was 0.89. There was no correlation between the QOD-P section and the SF-36, but there were statistically significant correlations between the QOD-QoL and QOD-VAS sections with the SF-36. There was no correlation between the QOD-P section and the WHOQOL-BREF, but there were statistically significant correlations between the QOD-QoL and QOD-VAS sections with the SF-36 in most sections. Conclusion: The simplified Chinese version of the QOD was testified to be a reliable and valid questionnaire for evaluating patients with olfactory dysfunction living in mainland of China.The QOD-P section needs further modifications to properly adapt patients with Chinese cultural and knowledge background. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.
Cheung, Jason Pui Yin; Cheung, Prudence Wing Hang; Wong, Carlos King Ho; Samartzis, Dino; Luk, Keith Dip-Kei; Lam, Cindy Lo Kuen; Cheung, Kenneth Man Chee
2016-12-15
Questionnaire translation and validation. The aim of this study was to translate and cross-culturally adapt the Early Onset Scoliosis-24 item Questionnaire (EOSQ-24) into traditional Chinese, and to assess its validity, reliability, and sensitivity in Southern-Chinese patients diagnosed with early onset scoliosis (EOS). Relying on radiographs alone for assessing treatment outcomes in EOS patients is inadequate. To properly gauge health-related quality of life, a disease-specific instrument that assesses patient quality of life and the burden of primary caregivers is necessary. The EOSQ-24 was created for this purpose, but it has not been adapted to the Chinese language. The translation and cross-cultural adaptation of the original English EOSQ-24 were performed using the method of double forward and single backward translations, followed by a panel review. EOS patients of Southern-Chinese descent were recruited, via convenience sampling from a scoliosis specialty clinic. These patients' parents/caretakers were then administered the traditional Chinese EOSQ-24, Likert Scale regarding the understanding of completed EOSQ-24, and the Child Health Questionnaire Parent Form 50 (CHQ-PF50) (Traditional Chinese). Reliability was analyzed using Cronbach alpha. Construct validity of domains and subdomains was assessed using Spearman correlation test against CHQ-PF50 domains with similar constructs. Sensitivity of the EOSQ-24 scores was determined by performing known group comparisons. A total of 100 EOS patients were recruited. A very good reliability was demonstrated (Cronbach α: 0.896) and internal consistency of all domains was excellent (Cronbach α: 0.829-0.919). Subdomain scores of EOSQ-24 and CHQ-PF50 had significant correlations (P < 0.001), indicating a good construct validity. This is the first psychometric study to translate and adapt the EOSQ-24 questionnaire for Chinese EOS patients and it has been found to have satisfactory validity, reliability, and sensitivity. It is a useful disease-specific instrument for assessing patients' quality of life and the burden of caregivers. 2.
Psychometrics of chronic liver disease questionnaire in Chinese chronic hepatitis B patients.
Zhou, Kai-Na; Zhang, Min; Wu, Qian; Ji, Zhen-Hao; Zhang, Xiao-Mei; Zhuang, Gui-Hua
2013-06-14
To evaluate psychometrics of the Chinese (mainland) chronic liver disease questionnaire (CLDQ) in patients with chronic hepatitis B (CHB). A cross-sectional sample of 460 Chinese patients with CHB was selected from the Outpatient Department of the Eighth Hospital of Xi'an, including CHB (CHB without cirrhosis) (n = 323) and CHB-related cirrhosis (n = 137). The psychometrics includes reliability, validity and sensitivity. Internal consistency reliability was measured using Cronbach's α. Convergent and discriminant validity was evaluated by item-scale correlation. Factorial validity was explored by principal component analysis with varimax rotation. Sensitivity was assessed using Cohen's effect size (ES), and independent sample t test between CHB and CHB-related cirrhosis groups and between alanine aminotransferase (ALT) normal and abnormal groups after stratifying the disease (CHB and CHB-related cirrhosis). Internal consistency reliability of the CLDQ was 0.83 (range: 0.65-0.90). Most of the hypothesized item-scale correlations were 0.40 or over, and all of such hypothesized correlations were higher than the alternative ones, indicating satisfactory convergent and discriminant validity. Six factors were extracted after varimax rotation from the 29 items of CLDQ. The eligible Cohen's ES with statistically significant independent sample t test was found in the overall CLDQ and abdominal, systematic, activity scales (CHB vs CHB-related cirrhosis), and in the overall CLDQ and abdominal scale in the stratification of patients with CHB (ALT normal vs abnormal). The CLDQ has acceptable reliability, validity and sensitivity in Chinese (mainland) patients with CHB.
Mota-Anaya, Evelin; Yumpo-Cárdenas, Daniel; Alva-Bravo, Edmundo; Wright-Nunes, Julie; Mayta-Tristán, Percy
2016-08-08
Chronic kidney disease (CKD) affects 50 million people globally. Several studies show the importance of implementing interventions that enhance patients knowledge about their disease. In 2011 the Kidney Disease Knowledge Survey (KiKS) was developed: a questionnaire that assesses the specific knowledge about chronic kidney disease in pre-dialysis patients. To translate to Spanish, culturally adapt and validate the Kidney Disease Knowledge Survey questionnaire in a population of patients with pre-dialysis chronic kidney disease. We carried out a Spanish translation and cross-cultural adaptation of the Kidney Disease Knowledge Survey questionnaire. Subsequently, we determined its validity and reliability. We determined the validity through construct validity; and reliability by evaluating its internal consistency and its intra-observer reliability (test-retest). We found a good internal consistency (Kuder-Richardson = 0.85). The intra-observer reliability was measured by the intra-class correlation coefficient that yielded a value of 0.78 (95% CI: 0.5-1.0). This value indicated a good reproducibility; also, the mean difference of -1.1 test-retest SD 6.0 (p = 0.369) confirms this finding. The translated Spanish version of the Kidney Disease Knowledge Survey is acceptable and equivalent to the original version; it also has a good reliability, validity and reproducibility. Therefore, it can be used in a population of patients with pre-dialysis chronic kidney disease.
Zumpano, Camila Eugênia; Mendonça, Tânia Maria da Silva; Silva, Carlos Henrique Martins da; Correia, Helena; Arnold, Benjamin; Pinto, Rogério de Melo Costa
2017-01-23
This study aimed to perform the cross-cultural adaptation and validation of the Patient-Reported Outcomes Measurement Information System (PROMIS) Global Health scale in the Portuguese language. The ten Global Health items were cross-culturally adapted by the method proposed in the Functional Assessment of Chronic Illness Therapy (FACIT). The instrument's final version in Portuguese was self-administered by 1,010 participants in Brazil. The scale's precision was verified by floor and ceiling effects analysis, reliability of internal consistency, and test-retest reliability. Exploratory and confirmatory factor analyses were used to assess the construct's validity and instrument's dimensionality. Calibration of the items used the Gradual Response Model proposed by Samejima. Four global items required adjustments after the pretest. Analysis of the psychometric properties showed that the Global Health scale has good reliability, with Cronbach's alpha of 0.83 and intra-class correlation of 0.89. Exploratory and confirmatory factor analyses showed good fit in the previously established two-dimensional model. The Global Physical Health and Global Mental Health scale showed good latent trait coverage according to the Gradual Response Model. The PROMIS Global Health items showed equivalence in Portuguese compared to the original version and satisfactory psychometric properties for application in clinical practice and research in the Brazilian population.
Ul-Haq, Zaheer; Effendi, Juweria Shahrukh; Ashraf, Sajda; Bkhaitan, Majdi M
2017-06-01
In the current study, quantitative three-dimensional structure-activity-relationship (3D-QSAR) method was performed to design a model for new chemical entities by utilizing pyrazolopyrimidines. Their inhibiting activity on receptor IL-2 Itk correlates descriptors based on topology and hydrophobicity. The best model developed by ligand-based (atom-based) approach has correlation-coefficient of r 2 : 0.987 and cross-validated squared correlation-coefficient of q 2 : 0.541 with an external prediction capability of r 2 : 0.944. Whereas the best selected model developed by structured-based (receptor-based) approach has correlation-coefficient of r 2 : 0.987, cross-validated squared correlation-coefficient of q 2 : 0.637 with an external predictive ability of r 2 : 0.941. The statistical parameters prove that structure-based gave a better model to design new chemical scaffolds. The results achieved indicated that hydrophobicity at R 1 location play a vital role in the inhibitory activity and introduction of appropriately bulky and strongly hydrophobic-groups at position 3 of the terminal phenyl-group which is highly significant to enhance the activity. Six new pyrazolopyrimidine derivatives were designed. Docking simulation study was carried out and their inhibitory activity was predicted by the best structure based model with predictive activity of ranging from 8.43 to 8.85 log unit. The interacting residues PHE435, ASP500, LYS391, GLU436, MET438, CYS442, ILE369, VAL377 of PDB 4HCT were studied with respect to type of bonding with the new compounds. This study was aimed to search out more potent inhibitors of IL-2 Itk. Copyright © 2017 Elsevier Inc. All rights reserved.
Validation of the Narrowing Beam Walking Test in Lower Limb Prosthesis Users.
Sawers, Andrew; Hafner, Brian
2018-04-11
To evaluate the content, construct, and discriminant validity of the Narrowing Beam Walking Test (NBWT), a performance-based balance test for lower limb prosthesis users. Cross-sectional study. Research laboratory and prosthetics clinic. Unilateral transtibial and transfemoral prosthesis users (N=40). Not applicable. Content validity was examined by quantifying the percentage of participants receiving maximum or minimum scores (ie, ceiling and floor effects). Convergent construct validity was examined using correlations between participants' NBWT scores and scores or times on existing clinical balance tests regularly administered to lower limb prosthesis users. Known-groups construct validity was examined by comparing NBWT scores between groups of participants with different fall histories, amputation levels, amputation etiologies, and functional levels. Discriminant validity was evaluated by analyzing the area under each test's receiver operating characteristic (ROC) curve. No minimum or maximum scores were recorded on the NBWT. NBWT scores demonstrated strong correlations (ρ=.70‒.85) with scores/times on performance-based balance tests (timed Up and Go test, Four Square Step Test, and Berg Balance Scale) and a moderate correlation (ρ=.49) with the self-report Activities-specific Balance Confidence scale. NBWT performance was significantly lower among participants with a history of falls (P=.003), transfemoral amputation (P=.011), and a lower mobility level (P<.001). The NBWT also had the largest area under the ROC curve (.81) and was the only test to exhibit an area that was statistically significantly >.50 (ie, chance). The results provide strong evidence of content, construct, and discriminant validity for the NBWT as a performance-based test of balance ability. The evidence supports its use to assess balance impairments and fall risk in unilateral transtibial and transfemoral prosthesis users. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Aguiar, A S; Bataglion, C; Visscher, C M; Bevilaqua Grossi, D; Chaves, T C
2017-07-01
Fear of movement (kinesiophobia) seems to play an important role in the development of chronic pain. However, for temporomandibular disorders (TMD), there is a scarcity of studies about this topic. The Tampa Scale for Kinesiophobia for TMD (TSK/TMD) is the most widely used instrument to measure fear of movement and it is not available in Brazilian Portuguese. The purpose of this study was to culturally adapt the TSK/TMD to Brazilian Portuguese and to assess its psychometric properties regarding internal consistency, reliability, and construct and structural validity. A total of 100 female patients with chronic TMD participated in the validation process of the TSK/TMD-Br. The intraclass correlation coefficient (ICC) was used for statistical analysis of reliability (test-retest), Cronbach's alpha for internal consistency, Spearman's rank correlation for construct validity and confirmatory factor analysis (CFA) for structural validity. CFA endorsed the pre-specified model with two domains and 12-items (Activity Avoidance - AA/Somatic Focus - SF) and all items obtained a loading factor greater than 0·4. Acceptable levels of reliability were found (ICC > 0·75) for all questions and domains of the TSK/TMD-Br. For internal consistency, Cronbach's α of 0·78 for both domains were found. Moderate correlations (0·40 < r < 0.60) were observed for 84% of the analyses conducted between TSK/TMD-Br scores versus catastrophising, depression and jaw functional limitation. TSK/TMD-Br 12 items and two-factor demonstrated sound psychometric properties (transcultural validity, reliability, internal consistency and structural validity). In such a way, the instrument can be used in clinical settings and for research purposes. © 2017 John Wiley & Sons Ltd.
Abdovic, Slaven; Mocic Pavic, Ana; Milosevic, Milan; Persic, Mladen; Senecic-Cala, Irena; Kolacek, Sanja
2013-12-01
To assess the reliability and validity of IMPACT-III (HR), a disease-specific, health-related quality of life instrument in Croatian children with inflammatory bowel disease. In a multicenter study, 104 children participated in a validation study of IMPACT-III (HR) cross-culturally adapted for Croatia. Factor analysis was used to determine optimal domain structure for this cohort, analysis of Cronbach's alpha coefficients to test internal reliability, ANOVA to assess discriminant validity, and correlation with Pediatric Quality of Life Inventory, Version 4.0 (PedsQL) using Pearson correlation coefficients to assess concurrent validity. Cronbach's alpha for the IMPACT-III (HR) total score was 0.92. The most robust factor solution was a 5-domain structure: Symptoms, Concerns, Socializing, Body Image, and Worry about Stool, all of which demonstrated good internal reliability (α=0.60-0.89), but two items were dropped to achieve this. Discriminant validity was demonstrated by significant differences (P<0.001) in mean IMPACT-III (HR) scores between quiescent and mild or moderate-severe disease activity groups for total (148 vs. 139 or 125) and following factor scores: Symptoms (84 vs. 71 or 61), Socializing (91 vs. 83 or 76), and Worry about Stool (significant only between quiescent and moderate-severe groups, 90 vs. 62, respectively). Concurrent validity of IMPACT-III (HR) with PedsQL showed significant correlation, which was strongest when similar domains were compared. IMPACT-III (HR) appears to be useful tool to measure health-related quality of life in Croatian children with Crohn's disease and ulcerative colitis. Copyright © 2012 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.
Ang, Rebecca P; Chong, Wan Har; Huan, Vivien S; Yeo, Lay See
2007-01-01
This article reports the development and initial validation of scores obtained from the Adolescent Concerns Measure (ACM), a scale which assesses concerns of Asian adolescent students. In Study 1, findings from exploratory factor analysis using 619 adolescents suggested a 24-item scale with four correlated factors--Family Concerns (9 items), Peer Concerns (5 items), Personal Concerns (6 items), and School Concerns (4 items). Initial estimates of convergent validity for ACM scores were also reported. The four-factor structure of ACM scores derived from Study 1 was confirmed via confirmatory factor analysis in Study 2 using a two-fold cross-validation procedure with a separate sample of 811 adolescents. Support was found for both the multidimensional and hierarchical models of adolescent concerns using the ACM. Internal consistency and test-retest reliability estimates were adequate for research purposes. ACM scores show promise as a reliable and potentially valid measure of Asian adolescents' concerns.
Convergent validation of EQ-5D-5L in patients with Parkinson's disease.
Alvarado-Bolaños, Alonso; Cervantes-Arriaga, Amin; Rodríguez-Violante, Mayela; Llorens-Arenas, Rodrigo; Calderón-Fajardo, Humberto; Millán-Cepeda, Roxanna; Leal-Ortega, Roberto; Estrada-Bellmann, Ingrid; Zuñiga-Ramírez, Carlos
2015-11-15
The European Quality of Life Questionnaire 5 level version (EQ-5D-5L) is a recently updated instrument to assess Health-Related Quality of Life (HRQoL) that has not been validated extensively. The main objective of this study was to evaluate the internal consistency and convergent validation of the EQ-5D-5L in a large sample of subjects with Parkinson's disease (PD). A cross-sectional study was carried out. Consecutive Mexican subjects with PD were included. HRQoL was assessed using the EQ-5D-5L and the PDQ-8. Validity of the EQ-5D-5L was assessed determining its association with clinical ratings of disease severity, as well as correlation with PDQ-8. Additionally, performance was evaluated along predefined groups based on clinical and demographic data of known determinants of quality of life. A total of 585 patients were included for this study. A strong correlation was found between EQ-5D-5L index and PDQ-8 index (Spearman's correlation coefficient=-0.75; p<0.001). Correlation between EQ-5D-5L index and PDQ-8 index remained strong (-0.60 to -0.78; p values <0.001) through all predefined groups. EQ-5D-5L scored higher in those patients with dyskinesia, wearing off, freezing, postural instability, cognitive impairment or depressive mood (p values <0.001). The EQ-5D-5L is a valid instrument for evaluating HRQoL in PD, performing adequately irrespective of heterogeneous clinical and demographic characteristics, and showing to be sensitive to features of advanced disease and treatment complications. Copyright © 2015 Elsevier B.V. All rights reserved.
Baradaran, Aslan; Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Kachooei, Amir Reza
2016-04-01
Prospective study. We aimed to validate the Persian version of the modified Oswestry disability questionnaire (MODQ) in patients with low back pain. Modified Oswestry low back pain disability questionnaire is a well-known condition-specific outcome measure that helps quantify disability in patients with lumbar syndromes. To test the validity in a pilot study, the Persian MODQ was administered to 25 individuals with low back pain. We then enrolled 200 consecutive patients with low back pain to fill the Persian MODQ as well as the short form 36 (SF-36) questionnaire. Convergent validity of the MODQ was tested using the Spearman's correlation coefficient between the MODQ and SF-36 subscales. Intraclass correlation coefficient (ICC) and Cronbach's α coefficient were measured to test the reliability between test and retest and internal consistency of all items, respectively. ICC for individual items ranged from 0.43 to 0.80 showing good reliability and reproducibility of each individual item. Cronbach's α coefficient was 0.69 showing good internal consistency across all 10 items of the Persian MODQ. Total MODQ score showed moderate to strong correlation with the eight subscales and the two domains of the SF-36. The highest correlation was between the MODQ and the physical functioning subscale of the SF-36 (r=-0.54, p<0.001) and the physical component domain of the SF-36 (r=-0.55, p<0.001) showing that MODQ is measuring what it is supposed to measure in terms of disability and physical function. Persian version of the MODQ is a valid and reliable tool for the assessment of the disability following low back pain.
Perspectives of Cross-Correlation in Seismic Monitoring at the International Data Centre
NASA Astrophysics Data System (ADS)
Bobrov, Dmitry; Kitov, Ivan; Zerbo, Lassina
2014-03-01
We demonstrate that several techniques based on waveform cross-correlation are able to significantly reduce the detection threshold of seismic sources worldwide and to improve the reliability of arrivals by a more accurate estimation of their defining parameters. A master event and the events it can find using waveform cross-correlation at array stations of the International Monitoring System (IMS) have to be close. For the purposes of the International Data Centre (IDC), one can use the spatial closeness of the master and slave events in order to construct a new automatic processing pipeline: all qualified arrivals detected using cross-correlation are associated with events matching the current IDC event definition criteria (EDC) in a local association procedure. Considering the repeating character of global seismicity, more than 90 % of events in the reviewed event bulletin (REB) can be built in this automatic processing. Due to the reduced detection threshold, waveform cross-correlation may increase the number of valid REB events by a factor of 1.5-2.0. Therefore, the new pipeline may produce a more comprehensive bulletin than the current pipeline—the goal of seismic monitoring. The analysts' experience with the cross correlation event list (XSEL) shows that the workload of interactive processing might be reduced by a factor of two or even more. Since cross-correlation produces a comprehensive list of detections for a given master event, no additional arrivals from primary stations are expected to be associated with the XSEL events. The number of false alarms, relative to the number of events rejected from the standard event list 3 (SEL3) in the current interactive processing—can also be reduced by the use of several powerful filters. The principal filter is the difference between the arrival times of the master and newly built events at three or more primary stations, which should lie in a narrow range of a few seconds. In this study, one event at a distance of about 2,000 km from the main shock was formed by three stations, with the stations and both events on the same great circle. Such spurious events are rejected by checking consistency between detections at stations at different back azimuths from the source region. Two additional effective pre-filters are f-k analysis and F prob based on correlation traces instead of original waveforms. Overall, waveform cross-correlation is able to improve the REB completeness, to reduce the workload related to IDC interactive analysis, and to provide a precise tool for quality check for both arrivals and events. Some major improvements in automatic and interactive processing achieved by cross-correlation are illustrated using an aftershock sequence from a large continental earthquake. Exploring this sequence, we describe schematically the next steps for the development of a processing pipeline parallel to the existing IDC one in order to improve the quality of the REB together with the reduction of the magnitude threshold.
Lee, Jung Sub; Shin, Jong Ki; Son, Seung Min; An, Sung Jin; Kang, Sung Shik
2014-07-01
We aimed to evaluate the reliability and validity of the adapted Korean version of the Quality-of-Life Questionnaire of the European Foundation for Osteoporosis (QUALEFFO-26). Translation/retranslation of the English version of QUALEFFO was conducted, and all steps of the cross-cultural adaptation process were performed. The Korean version of the visual analog scale measure of pain, QUALEFFO-26 and the previously validated Short Form-36 (SF-36) were mailed to 162 consecutive patients with osteoporosis. Factor analysis and reliability assessment by kappa statistics of agreement for each item, the intraclass correlation coefficient and Cronbach's α were conducted. Construct validity was also evaluated by comparing the responses of QUALEFFO-26 with the responses of SF-36 using Pearson's correlation coefficient. Factor analysis extracted 3 factors. All items had a kappa statistics of agreement greater than 0.6. The QUALEFFO-26 showed good test/retest reliability (QUALEFFO-26: 0.8271). Internal consistency of Cronbach's α was found to be very good (QUALEFFO-26: 0.873). The Korean version of QUALEFFO-26 showed good significant correlation with SF-36 total score and with single SF-36 domains scores. The adapted Korean version of the QUALEFFO-26 was successfully translated and showed acceptable measurement properties and, as such, is considered suitable for outcome assessments in the Korean-speaking patients with osteoporosis.
[Selection of risk and diagnosis in diabetic polyneuropathy. Validation of method of new systems].
Jurado, Jerónimo; Caula, Jacinto; Pou i Torelló, Josep Maria
2006-06-30
In a previous study we developed a specific algorithm, the polyneuropathy selection method (PSM) with 4 parameters (age, HDL-C, HbA1c, and retinopathy), to select patients at risk of diabetic polyneuropathy (DPN). We also developed a simplified method for DPN diagnosis: outpatient polyneuropathy diagnosis (OPD), with 4 variables (symptoms and 3 objective tests). To confirm the validity of conventional tests for DPN diagnosis; to validate the discriminatory power of the PSM and the diagnostic value of OPD by evaluating their relationship to electrodiagnosis studies and objective clinical neurological assessment; and to evaluate the correlation of DPN and pro-inflammatory status. Cross-sectional, crossed association for PSM validation. Paired samples for OPD validation. Primary care in 3 counties. Random sample of 75 subjects from the type-2 diabetes census for PSM evaluation. Thirty DPN patients and 30 non-DPN patients (from 2 DM2 sub-groups in our earlier study) for OPD evaluation. The gold standard for DPN diagnosis will be studied by means of a clinical neurological study (symptoms, physical examination, and sensitivity tests) and electrodiagnosis studies (sensitivity and motor EMG). Risks of neuropathy, macroangiopathy and pro-inflammatory status (PCR, TNF soluble fraction and total TGF-beta1) will be studied in every subject. Electrodiagnosis studies should confirm the validity of conventional tests for DPN diagnosis. PSM and OPD will be valid methods for selecting patients at risk and diagnosing DPN. There will be a significant relationship between DPN and pro-inflammatory tests.
Simple shoulder test and Oxford Shoulder Score: Persian translation and cross-cultural validation.
Naghdi, Soofia; Nakhostin Ansari, Noureddin; Rustaie, Nilufar; Akbari, Mohammad; Ebadi, Safoora; Senobari, Maryam; Hasson, Scott
2015-12-01
To translate, culturally adapt, and validate the simple shoulder test (SST) and Oxford Shoulder Score (OSS) into Persian language using a cross-sectional and prospective cohort design. A standard forward and backward translation was followed to culturally adapt the SST and the OSS into Persian language. Psychometric properties of floor and ceiling effects, construct convergent validity, discriminant validity, internal consistency reliability, test-retest reliability, standard error of the measurement (SEM), smallest detectable change (SDC), and factor structure were determined. One hundred patients with shoulder disorders and 50 healthy subjects participated in the study. The PSST and the POSS showed no missing responses. No floor or ceiling effects were observed. Both the PSST and POSS detected differences between patients and healthy subjects supporting their discriminant validity. Construct convergent validity was confirmed by a very good correlation between the PSST and POSS (r = 0.68). There was high internal consistency for both the PSST (α = 0.73) and the POSS (α = 0.91 and 0.92). Test-retest reliability with 1-week interval was excellent (ICCagreement = 0.94 for PSST and 0.90 for POSS). Factor analyses demonstrated a three-factor solution for the PSST (49.7 % of variance) and a two-factor solution for the POSS (61.6 % of variance). The SEM/SDC was satisfactory for PSST (5.5/15.3) and POSS (6.8/18.8). The PSST and POSS are valid and reliable outcome measures for assessing functional limitations in Persian-speaking patients with shoulder disorders.
Multivariate pattern analysis for MEG: A comparison of dissimilarity measures.
Guggenmos, Matthias; Sterzer, Philipp; Cichy, Radoslaw Martin
2018-06-01
Multivariate pattern analysis (MVPA) methods such as decoding and representational similarity analysis (RSA) are growing rapidly in popularity for the analysis of magnetoencephalography (MEG) data. However, little is known about the relative performance and characteristics of the specific dissimilarity measures used to describe differences between evoked activation patterns. Here we used a multisession MEG data set to qualitatively characterize a range of dissimilarity measures and to quantitatively compare them with respect to decoding accuracy (for decoding) and between-session reliability of representational dissimilarity matrices (for RSA). We tested dissimilarity measures from a range of classifiers (Linear Discriminant Analysis - LDA, Support Vector Machine - SVM, Weighted Robust Distance - WeiRD, Gaussian Naïve Bayes - GNB) and distances (Euclidean distance, Pearson correlation). In addition, we evaluated three key processing choices: 1) preprocessing (noise normalisation, removal of the pattern mean), 2) weighting decoding accuracies by decision values, and 3) computing distances in three different partitioning schemes (non-cross-validated, cross-validated, within-class-corrected). Four main conclusions emerged from our results. First, appropriate multivariate noise normalization substantially improved decoding accuracies and the reliability of dissimilarity measures. Second, LDA, SVM and WeiRD yielded high peak decoding accuracies and nearly identical time courses. Third, while using decoding accuracies for RSA was markedly less reliable than continuous distances, this disadvantage was ameliorated by decision-value-weighting of decoding accuracies. Fourth, the cross-validated Euclidean distance provided unbiased distance estimates and highly replicable representational dissimilarity matrices. Overall, we strongly advise the use of multivariate noise normalisation as a general preprocessing step, recommend LDA, SVM and WeiRD as classifiers for decoding and highlight the cross-validated Euclidean distance as a reliable and unbiased default choice for RSA. Copyright © 2018 Elsevier Inc. All rights reserved.
Cruz, Luciane Nascimento; Camey, Suzi Alves; Fleck, Marcelo Pio; Polanczyk, Carisi Anne
2009-10-01
This study aimed to assess the validity and reliability of World Health Organization Quality of Life Instrument (WHOQOL)-brief and SF-36 in patients with coronary artery disease (CAD). Considering that depression is known to be associated with bad outcomes in CAD and it is highly associated with poor Quality of Life (QOL), we tested the correlation between WHOQOL and SF-36 and an instrument to screen depressive symptoms. It is a cross-sectional survey conducted in 103 patients with documented CAD. QOL was measured through WHOQOL-brief and SF-36 and depressive symptoms were assessed by the Beck Depression Inventory (BDI). To evaluate convergent validity, the correlations between both QOL assessment instruments were examined; discriminant validity was assessed through BDI and QOL instruments correlations. Coefficient Cronbach's alpha was used to test reliability. Percentages of floor and ceiling effects were higher in SF-36 scores than the WHOQOL-brief ones. Although WHOQOL-brief showed a maximum of 1% of floor effect and 9% of ceiling effect, SF-36 presented 40 and 32%, respectively. Internal consistency reliability ranged from 0.65 to 0.85 for the WHOQOL-brief and 0.57 to 0.89 for the SF-36. Correlations between subscales of WHOQOL-brief and BDI ranged from -0.74 to -0.61 and correlations between subscales of SF-36 and BDI ranged from -0.68 to -0.26. SF-36 and WHOQOL-brief seem to be valid and consistent QOL measures in patients with CAD. Researchers should define the aims of their studies before choosing which instrument to use, because they appear to measure different constructs of QOL.
McLeod, Jessica; Chen, Tzu-An; Nicklas, Theresa A.; Baranowski, Tom
2013-01-01
Abstract Background Television viewing is an important modifiable risk factor for childhood obesity. However, valid methods for measuring children's TV viewing are sparse and few studies have included Latinos, a population disproportionately affected by obesity. The goal of this study was to test the reliability and convergent validity of four TV viewing measures among low-income Latino preschool children in the United States. Methods Latino children (n=96) ages 3–5 years old were recruited from four Head Start centers in Houston, Texas (January, 2009, to June, 2010). TV viewing was measured concurrently over 7 days by four methods: (1) TV diaries (parent reported), (2) sedentary time (accelerometry), (3) TV Allowance (an electronic TV power meter), and (4) Ecological Momentary Assessment (EMA) on personal digital assistants (parent reported). This 7-day procedure was repeated 3–4 weeks later. Test–retest reliability was determined by intraclass correlations (ICC). Spearman correlations (due to nonnormal distributions) were used to determine convergent validity compared to the TV diary. Results The TV diary had the highest test–retest reliability (ICC=0.82, p<0.001), followed by the TV Allowance (ICC=0.69, p<0.001), EMA (ICC=0.46, p<0.001), and accelerometry (ICC=0.36–0.38, p<0.01). The TV Allowance (r=0.45–0.55, p<0.001) and EMA (r=0.47–0.51, p<0.001) methods were significantly correlated with TV diaries. Accelerometer-determined sedentary minutes were not correlated with TV diaries. The TV Allowance and EMA methods were significantly correlated with each other (r=0.48–0.53, p<0.001). Conclusions The TV diary is feasible and is the most reliable method for measuring US Latino preschool children's TV viewing. PMID:23270534
Clinical audit project in undergraduate medical education curriculum: an assessment validation study
Steketee, Carole; Mak, Donna
2016-01-01
Objectives To evaluate the merit of the Clinical Audit Project (CAP) in an assessment program for undergraduate medical education using a systematic assessment validation framework. Methods A cross-sectional assessment validation study at one medical school in Western Australia, with retrospective qualitative analysis of the design, development, implementation and outcomes of the CAP, and quantitative analysis of assessment data from four cohorts of medical students (2011- 2014). Results The CAP is fit for purpose with clear external and internal alignment to expected medical graduate outcomes. Substantive validity in students’ and examiners’ response processes is ensured through relevant methodological and cognitive processes. Multiple validity features are built-in to the design, planning and implementation process of the CAP. There is evidence of high internal consistency reliability of CAP scores (Cronbach’s alpha > 0.8) and inter-examiner consistency reliability (intra-class correlation>0.7). Aggregation of CAP scores is psychometrically sound, with high internal consistency indicating one common underlying construct. Significant but moderate correlations between CAP scores and scores from other assessment modalities indicate validity of extrapolation and alignment between the CAP and the overall target outcomes of medical graduates. Standard setting, score equating and fair decision rules justify consequential validity of CAP scores interpretation and use. Conclusions This study provides evidence demonstrating that the CAP is a meaningful and valid component in the assessment program. This systematic framework of validation can be adopted for all levels of assessment in medical education, from individual assessment modality, to the validation of an assessment program as a whole. PMID:27716612
Tor, Elina; Steketee, Carole; Mak, Donna
2016-09-24
To evaluate the merit of the Clinical Audit Project (CAP) in an assessment program for undergraduate medical education using a systematic assessment validation framework. A cross-sectional assessment validation study at one medical school in Western Australia, with retrospective qualitative analysis of the design, development, implementation and outcomes of the CAP, and quantitative analysis of assessment data from four cohorts of medical students (2011- 2014). The CAP is fit for purpose with clear external and internal alignment to expected medical graduate outcomes. Substantive validity in students' and examiners' response processes is ensured through relevant methodological and cognitive processes. Multiple validity features are built-in to the design, planning and implementation process of the CAP. There is evidence of high internal consistency reliability of CAP scores (Cronbach's alpha > 0.8) and inter-examiner consistency reliability (intra-class correlation>0.7). Aggregation of CAP scores is psychometrically sound, with high internal consistency indicating one common underlying construct. Significant but moderate correlations between CAP scores and scores from other assessment modalities indicate validity of extrapolation and alignment between the CAP and the overall target outcomes of medical graduates. Standard setting, score equating and fair decision rules justify consequential validity of CAP scores interpretation and use. This study provides evidence demonstrating that the CAP is a meaningful and valid component in the assessment program. This systematic framework of validation can be adopted for all levels of assessment in medical education, from individual assessment modality, to the validation of an assessment program as a whole.
Burkey, Matthew D.; Ghimire, Lajina; Adhikari, Ramesh P.; Kohrt, Brandon A.; Jordans, Mark J. D.; Haroz, Emily; Wissow, Lawrence
2017-01-01
Systematic processes are needed to develop valid measurement instruments for disruptive behavior disorders (DBDs) in cross-cultural settings. We employed a four-step process in Nepal to identify and select items for a culturally valid assessment instrument: 1) We extracted items from validated scales and local free-list interviews. 2) Parents, teachers, and peers (n=30) rated the perceived relevance and importance of behavior problems. 3) Highly rated items were piloted with children (n=60) in Nepal. 4) We evaluated internal consistency of the final scale. We identified 49 symptoms from 11 scales, and 39 behavior problems from free-list interviews (n=72). After dropping items for low ratings of relevance and severity and for poor item-test correlation, low frequency, and/or poor acceptability in pilot testing, 16 items remained for the Disruptive Behavior International Scale—Nepali version (DBIS-N). The final scale had good internal consistency (α=0.86). A 4-step systematic approach to scale development including local participation yielded an internally consistent scale that included culturally relevant behavior problems. PMID:28093575
Near infrared spectroscopy for prediction of antioxidant compounds in the honey.
Escuredo, Olga; Seijo, M Carmen; Salvador, Javier; González-Martín, M Inmaculada
2013-12-15
The selection of antioxidant variables in honey is first time considered applying the near infrared (NIR) spectroscopic technique. A total of 60 honey samples were used to develop the calibration models using the modified partial least squares (MPLS) regression method and 15 samples were used for external validation. Calibration models on honey matrix for the estimation of phenols, flavonoids, vitamin C, antioxidant capacity (DPPH), oxidation index and copper using near infrared (NIR) spectroscopy has been satisfactorily obtained. These models were optimised by cross-validation, and the best model was evaluated according to multiple correlation coefficient (RSQ), standard error of cross-validation (SECV), ratio performance deviation (RPD) and root mean standard error (RMSE) in the prediction set. The result of these statistics suggested that the equations developed could be used for rapid determination of antioxidant compounds in honey. This work shows that near infrared spectroscopy can be considered as rapid tool for the nondestructive measurement of antioxidant constitutes as phenols, flavonoids, vitamin C and copper and also the antioxidant capacity in the honey. Copyright © 2013 Elsevier Ltd. All rights reserved.
CRISPR-Cas9-based target validation for p53-reactivating model compounds
Wanzel, Michael; Vischedyk, Jonas B; Gittler, Miriam P; Gremke, Niklas; Seiz, Julia R; Hefter, Mirjam; Noack, Magdalena; Savai, Rajkumar; Mernberger, Marco; Charles, Joël P; Schneikert, Jean; Bretz, Anne Catherine; Nist, Andrea; Stiewe, Thorsten
2015-01-01
Inactivation of the p53 tumor suppressor by Mdm2 is one of the most frequent events in cancer, so compounds targeting the p53-Mdm2 interaction are promising for cancer therapy. Mechanisms conferring resistance to p53-reactivating compounds are largely unknown. Here we show using CRISPR-Cas9–based target validation in lung and colorectal cancer that the activity of nutlin, which blocks the p53-binding pocket of Mdm2, strictly depends on functional p53. In contrast, sensitivity to the drug RITA, which binds the Mdm2-interacting N terminus of p53, correlates with induction of DNA damage. Cells with primary or acquired RITA resistance display cross-resistance to DNA crosslinking compounds such as cisplatin and show increased DNA cross-link repair. Inhibition of FancD2 by RNA interference or pharmacological mTOR inhibitors restores RITA sensitivity. The therapeutic response to p53-reactivating compounds is therefore limited by compound-specific resistance mechanisms that can be resolved by CRISPR-Cas9-based target validation and should be considered when allocating patients to p53-reactivating treatments. PMID:26595461
Moreno-Murcia, Juan A; Martínez-Galindo, Celestina; Moreno-Pérez, Víctor; Marcos, Pablo J.; Borges, Fernanda
2012-01-01
This study aimed to cross-validate the psychometric properties of the Basic Psychological Needs in Exercise Scale (BPNES) by Vlachopoulos and Michailidou, 2006 in a Spanish context. Two studies were conducted. Confirmatory factor analysis results confirmed the hypothesized three-factor solution In addition, we documented evidence of reliability, analysed as internal consistency and temporal stability. Future studies should analyse the scale's validity and reliability with different populations and check their experimental effect. Key pointsThe Basic Psychological Needs in Exercise Scale (BPNES) is valid and reliable for measuring basic psychological needs in healthy physical exercise in the Spanish context.The factor structure of three correlated factors has shown minimal invariance across gender. PMID:24149130
Ambrosio, Leire; Portillo, Mari Carmen; Rodríguez-Blázquez, Carmen; Rodriguez-Violante, Mayela; Castrillo, Juan Carlos Martínez; Arillo, Víctor Campos; Garretto, Nélida Susana; Arakaki, Tomoko; Dueñas, Marcos Serrano; Álvarez, Mario; Ibáñez, Ivonne Pedroso; Carvajal, Ana; Martínez-Martín, Pablo
2016-01-01
Understanding how a person lives with a chronic illness, such as Parkinson’s disease (PD), is necessary to provide individualized care and professionals role in person-centered care at clinical and community levels is paramount. The present study was aimed to analyze the psychometric properties of the Living with Chronic Illness-PD Scale (EC-PC) in a wide Spanish-speaking population with PD. International cross-sectional study with retest was carried out with 324 patients from four Latin American countries and Spain. Feasibility, acceptability, scaling assumptions, reliability, precision, and construct validity were tested. The study included 324 patients, with age (mean±s.d.) 66.67±10.68 years. None of the EC-PC items had missing values and all acceptability parameters fulfilled the standard criteria. Around two-third of the items (61.54%) met scaling assumptions standards. Concerning internal consistency, Cronbach’s alpha values were 0.68–0.88; item-total correlation was >0.30, except for two items; item homogeneity index was >0.30, and inter-item correlation values 0.14–0.76. Intraclass correlation coefficient for EC-PC stability was 0.76 and standard error of measurement (s.e.m.) for precision was 8.60 (for a EC-PC s.d.=18.57). EC-PC presented strong correlation with social support (rS=0.61) and moderate correlation with life satisfaction (rS=0.46). Weak and negligible correlations were found with the other scales. Internal validity correlations ranged from 0.46 to 0.78. EC-PC total scores were significantly different for each severity level based on Hoehn and Yahr and Clinical Impression of Severity Index, but not for Patient Global Impression of Severity. The EC-PC has satisfactory acceptability, reliability, precision, and validity to evaluate living with PD. PMID:28725703
Palacios, Cristina; Rivas-Tumanyan, Sona; Santiago-Rodríguez, Eduardo J; Sinigaglia, Olga; Ríos, Elaine M; Campos, Maribel; Diaz, Beatriz; Willett, Walter
2017-04-01
There are limited validated food frequency questionnaires (FFQs) for infants and toddlers, most of which were evaluated in Europe or Oceania, and the ones available for use in the United States have important limitations. Our aim was to assess the validity of an FFQ developed for infants and toddlers. A semi-quantitative FFQ was developed that included 52 food items, their sources, and portion sizes. The FFQ inquired about diets over the previous 7 days. Its validity was assessed in a cross-sectional study. Participants completed the FFQ, followed by a 24-hour recall on two occasions with 1 week between data collection. A total of 296 caregivers of infants and toddlers aged 0 to 24 months enrolled in the Special Supplemental Nutrition Program for Women, Infants, and Children, Puerto Rico. Intake of nutrients and food groups were averaged for the two FFQs and the two 24-hour food recalls, and adjusted for energy intake. Spearman correlations were performed for intakes of energy, nutrients, and foods between administrations and between instruments. Correlation coefficients were de-attenuated to account for variation in the 24-hour recalls. A total of 241 participants completed the study. Intake of all nutrients and foods were significantly correlated between FFQs and 24-hour recalls and between the means of FFQs and 24-hour food recalls. The de-attenuated correlation for nutrients between the FFQs and 24-hour recalls ranged from 0.26 (folate) to 0.77 (energy), with a mean correlation of 0.53. The de-attenuated correlation for food groups between the FFQs and 24-hour recalls ranged from 0.28 (sweets) to 0.80 (breast milk), with a mean correlation of 0.55. When analyses were restricted to those consuming foods other than breast milk or formula (n=186), results were similar. This semi-quantitative FFQ is a tool that offers reasonably valid rankings for intake of energy, nutrients, foods, and food groups in this sample of infants and toddlers. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
Validation of the Perceived Stigmatization Questionnaire for Brazilian adult burn patients.
Freitas, Noélle de Oliveira; Forero, Carlos García; Caltran, Marina Paes; Alonso, Jordi; Dantas, Rosana A Spadoti; Piccolo, Monica Sarto; Farina, Jayme Adriano; Lawrence, John W; Rossi, Lidia A
2018-01-01
Currently, there is no questionnaire to assess perceived stigmatization among people with visible differences in Brazil. The Perceived Stigmatization Questionnaire (PSQ), developed in the United States, is a valid instrument to assess the perception of stigmatizing behaviours among burn survivors. The objective of this cross-sectional and multicentre study was to assess the factor structure, reliability and validity of the Brazilian Portuguese version of the PSQ in burn patients. A Brazilian version of the 21-item PSQ was answered by 240 adult burn patients, undergoing rehabilitation in two burns units in Brazil. We tested its construct validity by correlating PSQ scores with depression (Beck Depression Index-BDI) and self-esteem (Rosenberg Self-Esteem Scale-RSE), as well as with two domains of the Revised Burn Specific Health Scale-BSHS-R: affect and body image, and interpersonal relationships. We used Confirmatory Item Factor Analysis (CIFA) to test whether the data fit a measurement model involving a three-factor structure (absence of friendly behaviour; confusing/staring behaviour; and hostile behaviour). We conducted Exploratory Factor Analyses (EFA) of the subscale in a 50% random sample of individuals (training split), treating items as ordinal categorical using unweighted least squares estimation. To assess discriminant validity of the Brazilian version of the PSQ we correlated PSQ scores with known groups (sex, total body surface area burned, and visibility of the scars) and assessed its reliability by means of Cronbach's alpha and using test-retest. Goodness-of-fit indices for confirmatory factor analysis were satisfactory for the PSQ, but not for the hostile behaviour subscale, which was modified to improve fit by eliminating 3 items. Cronbach's alphas for the PSQ refined version (PSQ-R) ranged from 0.65 to 0.88, with test-retest reliability 0.87 for the total score. The PSQ-R scores correlated strongly with depression (0.63; p < 0.001), self-esteem (-0.57; p < 0.001), body image (-0.63; p < 0.001), and interpersonal relationships (-0.55; p < 0.001). PSQ-R total scores were significantly lower for patients with visible scars (effect size = 0.51, p = 0.029). The PSQ-R showed reliability and validity comparable to the original version. However, the cross-cultural structure of the subscale "hostile behaviour" and sensitivity to change of the PSQ should be further evaluated.
Validation of the Perceived Stigmatization Questionnaire for Brazilian adult burn patients
Forero, Carlos García; Caltran, Marina Paes; Alonso, Jordi; Dantas, Rosana A. Spadoti; Piccolo, Monica Sarto; Farina, Jayme Adriano; Lawrence, John W.; Rossi, Lidia A.
2018-01-01
Currently, there is no questionnaire to assess perceived stigmatization among people with visible differences in Brazil. The Perceived Stigmatization Questionnaire (PSQ), developed in the United States, is a valid instrument to assess the perception of stigmatizing behaviours among burn survivors. The objective of this cross-sectional and multicentre study was to assess the factor structure, reliability and validity of the Brazilian Portuguese version of the PSQ in burn patients. A Brazilian version of the 21-item PSQ was answered by 240 adult burn patients, undergoing rehabilitation in two burns units in Brazil. We tested its construct validity by correlating PSQ scores with depression (Beck Depression Index-BDI) and self-esteem (Rosenberg Self-Esteem Scale-RSE), as well as with two domains of the Revised Burn Specific Health Scale—BSHS-R: affect and body image, and interpersonal relationships. We used Confirmatory Item Factor Analysis (CIFA) to test whether the data fit a measurement model involving a three-factor structure (absence of friendly behaviour; confusing/staring behaviour; and hostile behaviour). We conducted Exploratory Factor Analyses (EFA) of the subscale in a 50% random sample of individuals (training split), treating items as ordinal categorical using unweighted least squares estimation. To assess discriminant validity of the Brazilian version of the PSQ we correlated PSQ scores with known groups (sex, total body surface area burned, and visibility of the scars) and assessed its reliability by means of Cronbach's alpha and using test-retest. Goodness-of-fit indices for confirmatory factor analysis were satisfactory for the PSQ, but not for the hostile behaviour subscale, which was modified to improve fit by eliminating 3 items. Cronbach’s alphas for the PSQ refined version (PSQ-R) ranged from 0.65 to 0.88, with test-retest reliability 0.87 for the total score. The PSQ-R scores correlated strongly with depression (0.63; p < 0.001), self-esteem (-0.57; p < 0.001), body image (-0.63; p < 0.001), and interpersonal relationships (-0.55; p < 0.001). PSQ-R total scores were significantly lower for patients with visible scars (effect size = 0.51, p = 0.029). The PSQ-R showed reliability and validity comparable to the original version. However, the cross-cultural structure of the subscale “hostile behaviour” and sensitivity to change of the PSQ should be further evaluated. PMID:29381711
Junkes, Monica C; Fraiz, Fabian C; Sardenberg, Fernanda; Lee, Jessica Y; Paiva, Saul M; Ferreira, Fernanda M
2015-01-01
The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. The BREALD-30 demonstrated good internal reliability. Cronbach's alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent's perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent's perception regarding his/her child's oral health remained significant in the multivariate analysis. The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil.
Junkes, Monica C.; Fraiz, Fabian C.; Sardenberg, Fernanda; Lee, Jessica Y.; Paiva, Saul M.; Ferreira, Fernanda M.
2015-01-01
Objective The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. Methods After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. Results The BREALD-30 demonstrated good internal reliability. Cronbach’s alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent’s perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent’s perception regarding his/her child's oral health remained significant in the multivariate analysis. Conclusion The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil. PMID:26158724
Huang, Meng-Chuan; Lin, Kun-Der; Chen, Hung-Jiun; Wu, Yu-Ju; Chang, Chiao-I; Shin, Shyi-Jang; Hung, Hsin-Chia; Lee, Chien-Hung; Huang, Ya-Fang; Hsu, Chih-Cheng
2018-06-01
Few food frequency questionnaires (FFQs) have been developed to assess diet in diabetes patients. This cross-sectional study examined the validity of a 45-item FFQ assessing the intake of macronutrients against three 24-h dietary recalls (24-HDRs) in Taiwan, and compared vegetable and fruit intakes with carotenoid biomarkers. We recruited 126 adults with type 2 diabetes who completed the FFQ and three 24-HDRs administered by a registered dietitian. We measured plasma carotenoids (α-carotene, β-carotene and lutein) in 71 subjects. Partial Pearson correlation coefficients derived from the FFQs and three 24-HDRs and adjusted for energy were of 0.651, 0.587, 0.639 and 0.664 for protein, fat, carbohydrate and fiber, respectively. Cross-classification analysis revealed that 71.5⁻81% of the macronutrients and fiber were categorized into the same or adjacent quartiles by the FFQ and 24-HDRs. Bland⁻Altman plots revealed good agreement for energy/macronutrients/fiber across the range of intakes. Multiple linear regression of backward elimination revealed that tertile levels of dark- or light-colored vegetables obtained by the FFQ were significantly associated with plasma α-carotene and β-carotene, but not lutein. Fruit consumption did not correlate with carotenoid biomarkers. In conclusion, this short FFQ provided a valid assessment of macronutrients and fiber intake in type 2 diabetes patients. Vegetable consumption estimated by the FFQ corresponded to plasma α-carotene and β-carotene concentrations.
Crins, Martine H P; Terwee, Caroline B; Klausch, Thomas; Smits, Niels; de Vet, Henrica C W; Westhovens, Rene; Cella, David; Cook, Karon F; Revicki, Dennis A; van Leeuwen, Jaap; Boers, Maarten; Dekker, Joost; Roorda, Leo D
2017-07-01
The objective of this study was to assess the psychometric properties of the Dutch-Flemish Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function item bank in Dutch patients with chronic pain. A bank of 121 items was administered to 1,247 Dutch patients with chronic pain. Unidimensionality was assessed by fitting a one-factor confirmatory factor analysis and evaluating resulting fit statistics. Items were calibrated with the graded response model and its fit was evaluated. Cross-cultural validity was assessed by testing items for differential item functioning (DIF) based on language (Dutch vs. English). Construct validity was evaluated by calculation correlations between scores on the Dutch-Flemish PROMIS Physical Function measure and scores on generic and disease-specific measures. Results supported the Dutch-Flemish PROMIS Physical Function item bank's unidimensionality (Comparative Fit Index = 0.976, Tucker Lewis Index = 0.976) and model fit. Item thresholds targeted a wide range of physical function construct (threshold-parameters range: -4.2 to 5.6). Cross-cultural validity was good as four items only showed DIF for language and their impact on item scores was minimal. Physical Function scores were strongly associated with scores on all other measures (all correlations ≤ -0.60 as expected). The Dutch-Flemish PROMIS Physical Function item bank exhibited good psychometric properties. Development of a computer adaptive test based on the large bank is warranted. Copyright © 2017 Elsevier Inc. All rights reserved.
Maki, Dana; Rajab, Ebrahim; Watson, Paul J; Critchley, Duncan J
2014-12-01
Cross-cultural translation, adaptation, and psychometric testing. To cross-culturally translate and adapt the Roland-Morris Disability Questionnaire (RMDQ) into Modern Standard Arabic and examine its validity with Arabic-speaking patients with low back pain (LBP). The English RMDQ is valid, reliable, and commonly used to assess LBP disability in clinical practice and research. There is no valid and reliable version of the RMDQ in Modern Standard Arabic. The RMDQ was forward translated and back translated. An expert committee of musculoskeletal physiotherapists reviewed the translation. Eight patients with LBP evaluated item-by-item comprehensibility. Ten patients piloted the RMDQ for overall comprehensibility and acceptability. Seventeen bilingual patients tested the agreement of the Arabic and English RMDQs. Two-hundred one patients completed the RMDQ and the visual analogue scale. Sixty-four patients were followed-up for test-retest reliability. Translation of most items was uncontroversial. The expert committee found the Arabic RMDQ clinically and culturally appropriate. They reviewed item 11, addressing bending and kneeling, because this has a clinical significance and cultural/religious implication regarding prayer positions. All patients reported that it was easy to understand and complete. The Arabic RMDQ had high overall agreement with the English RMDQ for the global score (intraclass correlation coefficient [ICC] = 0.925; 0.811-0.972). Kappa statistics showed good item-by-item agreement (none ≤0.30). Mean (SD) RMDQ and visual analog scale scores of 201 patients were 10.53 (4.80) and 5.11 (2.28), respectively. The RMDQ had a low correlation against pain intensity (r = 0.259; P < 0.01). A Cronbach α of 0.729 showed high internal consistency. Test-retest reliability of the Arabic RMDQ was good (ICC = 0.900; 95% confidence interval, 0.753-0.951). Kappa statistics were high for 18 items and fair for 6. The Arabic version of the RMDQ has good comprehensibility and acceptability, high internal consistency and reliability, low correlation against pain intensity, and good agreement with the English RMDQ. We recommend its use with Arabic-speaking patients with LBP. 3.
Kues, Johanna N; Janda, Carolyn; Kleinstäuber, Maria; Weise, Cornelia
2016-10-01
With 75% of women of reproductive age affected, premenstrual symptoms are very common, ranging from emotional and cognitive to physical symptoms. Premenstrual Syndrome and Premenstrual Dysphoric Disorder can lead to substantial functional interference and psychological distress comparable to that of dysthymic disorders. The assessment of this impact is required as a part of the diagnostic procedure in the DSM-5. In the absence of a specific measure, the authors developed the PMS-Impact Questionnaire. A sample of 101 women reporting severe premenstrual complaints was assessed with the twenty-two items in the questionnaire during their premenstrual phase in an ongoing intervention study at the Philipps-University Marburg from August 2013 until January 2015. An exploratory factor analysis revealed a two-factor solution (labeled Psychological Impact and Functional Impact) with 18 items. A Cronbach's alpha of 0.90 for Psychological Impact and of 0.90 for Functional Impact indicated good reliability. Convergent construct validity was demonstrated by moderate to high correlations with the Pain Disability Index. Low correlations with the Big Five Inventory-10 indicated good divergent validity. The PMS-Impact Questionnaire was found to be a valid, reliable, and an economic measure to assess the impact of premenstrual symptoms. In future research, cross validations and confirmatory factor analyses should be conducted.
Game, Madhuri D.; Gabhane, K. B.; Sakarkar, D. M.
2010-01-01
A simple, accurate and precise spectrophotometric method has been developed for simultaneous estimation of clopidogrel bisulphate and aspirin by employing first order derivative zero crossing method. The first order derivative absorption at 232.5 nm (zero cross point of aspirin) was used for clopidogrel bisulphate and 211.3 nm (zero cross point of clopidogrel bisulphate) for aspirin.Both the drugs obeyed linearity in the concentration range of 5.0 μg/ml to 25.0 μg/ml (correlation coefficient r2<1). No interference was found between both determined constituents and those of matrix. The method was validated statistically and recovery studies were carried out to confirm the accuracy of the method. PMID:21969765
Yanagisawa, Ayumi; Sudo, Noriko; Amitani, Yukiko; Caballero, Yuko; Sekiyama, Makiko; Mukamugema, Christine; Matsuoka, Takuya; Imanishi, Hiroaki; Sasaki, Takayo; Matsuda, Hirotaka
2016-01-01
This study aimed to develop and evaluate the validity of a food frequency questionnaire (FFQ) for rural Rwandans. Since our FFQ was developed to assess malnutrition, it measured energy, protein, vitamin A, and iron intakes only. We collected 260 weighed food records (WFRs) from a total of 162 Rwandans. Based on the WFR data, we developed a tentative FFQ and examined the food list by percent contribution to energy and nutrient intakes. To assess the validity, nutrient intakes estimated from the FFQ were compared with those calculated from three-day WFRs by correlation coefficient and cross-classification for 17 adults. Cumulative contributions of the 18-item FFQ to the total intakes of energy and nutrients reached nearly 100%. Crude and energy-adjusted correlation coefficients ranged from −0.09 (vitamin A) to 0.58 (protein) and from −0.19 (vitamin A) to 0.68 (iron), respectively. About 50%–60% of the participants were classified into the same tertile. Our FFQ provided acceptable validity for energy and iron intakes and could rank Rwandan adults in eastern rural area correctly according to their energy and iron intakes. PMID:27429558
2012-01-01
Background Dizziness and comorbid anxiety may cause severe disability of patients with vestibulopathy, but can be addressed effectively with rehabilitation. For an individually adapted treatment, a structured assessment is needed. The Vertigo Symptom Scale (VSS) with two subscales assessing vertigo symptoms (VSS-VER) and associated symptoms (VSS-AA) might be used for this purpose. As there was no validated VSS available in German, the aim of the study was the translation and cross-cultural adaptation in German (VSS-G) and the investigation of its reliability, internal and external validity. Methods The VSS was translated into German according to recognized guidelines. Psychometric properties were tested on 52 healthy controls and 202 participants with vestibulopathy. Internal validity and reliability were investigated with factor analysis, Cronbach’s α and ICC estimations. Discriminant validity was analysed with the Mann–Whitney-U-Test between patients and controls and the ROC-Curve. Convergent validity was estimated with the correlation with the Hospital Anxiety Subscale (HADS-A), Dizziness Handicap Inventory (DHI) and frequency of dizziness. Results Internal validity: factor analysis confirmed the structure of two subscales. Reliability: VSS-G: α = 0.904 and ICC (CI) =0.926 (0.826, 0.965). Discriminant validity: VSS-VER differentiate patients and controls ROC (CI) =0.99 (0.98, 1.00). Convergent validity: VSS-G correlates with DHI (r = 0.554) and frequency (T = 0.317). HADS-A correlates with VSS-AA (r = 0.452) but not with VSS-VER (r = 0.186). Conclusions The VSS-G showed satisfactory psychometric properties to assess the severity of vertigo or vertigo-related symptoms. The VSS-VER can differentiate between healthy subjects and patients with vestibular disorders. The VSS-AA showed some screening properties with high sensitivity for patients with abnormal anxiety. PMID:22747644
Weigl, Martin; Wild, Heike
2017-09-15
To validate the International Classification of Functioning, Disability and Health Comprehensive Core Set for Osteoarthritis from the patient perspective in Europe. This multicenter cross-sectional study involved 375 patients with knee or hip osteoarthritis. Trained health professionals completed the Comprehensive Core Set, and patients completed the Short-Form 36 questionnaire. Content validity was evaluated by calculating prevalences of impairments in body function and structures, limitations in activities and participation and environmental factors, which were either barriers or facilitators. Convergent construct validity was evaluated by correlating the International Classification of Functioning, Disability and Health categories with the Short-Form 36 Physical Component Score and the SF-36 Mental Component Score in a subgroup of 259 patients. The prevalences of all body function, body structure and activities and participation categories were >40%, >32% and >20%, respectively, and all environmental factors were relevant for >16% of patients. Few categories showed relevant differences between knee and hip osteoarthritis. All body function categories and all but two activities and participation categories showed significant correlations with the Physical Component Score. Body functions from the ICF chapter Mental Functions showed higher correlations with the Mental Component Score than with the Physical Component Score. This study supports the validity of the International Classification of Functioning, Disability and Health Comprehensive Core Set for Osteoarthritis. Implications for Rehabilitation Comprehensive International Classification of Functioning, Disability and Health Core Sets were developed as practical tools for application in multidisciplinary assessments. The validity of the Comprehensive International Classification of Functioning, Disability and Health Core Set for Osteoarthritis in this study supports its application in European patients with osteoarthritis. The differences in results between this Europe validation study and a previous Singaporean validation study underscore the need to validate the International Classification of Functioning, Disability and Health Core Sets in different regions of the world.
Bokhof, Beate; Buyken, Anette E; Doğan, Canan; Karaboğa, Arzu; Kaiser, Josa; Sonntag, Antje; Kroke, Anja
2012-04-01
Nutrition-related health problems such as obesity are frequent among children and adolescents of Turkish descent living in Germany, yet data on their dietary habits are scarce. One reason might be the lack of validated assessment tools for this target group. We therefore aimed to validate protein and K intakes from one 24 h recall against levels estimated from one 24 h urine sample in children and adolescents of Turkish descent living in Germany. Cross-sectional analyses comprised estimation of mean differences, Pearson correlation coefficients, cross-classifications and Bland-Altman plots to assess the agreement between the nutritional intake estimated from a single 24 h recall and a single 24 h urine sample collected on the previous day. Dortmund, Germany. Data from forty-three study participants (aged 5-18 years; 26% overweight) with a traditional Turkish background were included. The 24 h recall significantly overestimated mean protein and K intake by 10·7 g/d (95% CI of mean difference: 0·6, 20·7 g/d) and 344 mg/d (95% CI 8, 680 mg/d), respectively. Correlations between intake estimates were r = 0·25 (P = 0·1) and 0·31 (P = 0·05). Both methods classified 70% and 69% of the participants into the same/adjacent quartile of protein and K intake and misclassified 7% and 7%, respectively, into the opposite quartile. Bland-Altman plots indicated a wide scattering of differences in both protein and K intake. Among children and adolescents of traditional Turkish descent living in Germany, one 24 h recall may only be valid for categorizing subjects into high, medium or low consumers.
The Work Disability Functional Assessment Battery (WD-FAB): Feasibility and Psychometric Properties
Meterko, Mark; Marfeo, Elizabeth E.; McDonough, Christine M.; Jette, Alan M.; Ni, Pengsheng; Bogusz, Kara; Rasch, Elizabeth K; Brandt, Diane E.; Chan, Leighton
2015-01-01
Objectives To assess the feasibility and psychometric properties of eight scales covering two domains of the newly developed Work Disability Functional Assessment Battery (WD-FAB): physical function (PF) and behavioral health (BH) function. Design Cross-sectional. Setting Community. Participants Adults unable to work due to a physical (n=497) or mental (n=476) disability. Interventions None. Main Outcome Measures Each disability group responded to a survey consisting of the relevant WD-FAB scales and existing measures of established validity. The WD-FAB scales were evaluated with regard to data quality (score distribution; percent “I don’t know” responses), efficiency of administration (number of items required to achieve reliability criterion; time required to complete the scale) by computerized adaptive testing (CAT), and measurement accuracy as tested by person fit. Construct validity was assessed by examining both convergent and discriminant correlations between the WD-FAB scales and scores on same-domain and cross-domain established measures. Results Data quality was good and CAT efficiency was high across both WD-FAB domains. Measurement accuracy was very good for the PF scales; BH scales demonstrated more variability. Construct validity correlations, both convergent and divergent, between all WD-FAB scales and established measures were in the expected direction and range of magnitude. Conclusions The data quality, CAT efficacy, person fit and construct validity of the WD-FAB scales were well supported and suggest that the WD-FAB could be used to assess physical and behavioral health function related to work disability. Variation in scale performance suggests the need for future work on item replenishment and refinement, particularly regarding the Self-Efficacy scale. PMID:25528263
Validation of the Headache Impact Test (HIT-6) in patients with chronic migraine.
Rendas-Baum, Regina; Yang, Min; Varon, Sepideh F; Bloudek, Lisa M; DeGryse, Ronald E; Kosinski, Mark
2014-08-01
The Headache Impact Test (HIT)-6 was developed and has been validated in patients with various types of headache. The objective of this study was to report the psychometric properties of the HIT-6 among patients with chronic migraine. Data came from two international, multicenter, randomized, double-blind, placebo-controlled clinical trials of chronic migraine patients (N = 1,384) undergoing prophylaxis therapy. Confirmatory factor analysis and differential item functioning (DIF) analysis were used to test the latent structure and cross-cultural comparability of the HIT-6. Reliability, construct validity, and responsiveness were assessed. Two sets of criterion groups were used: (1) 28-day headache frequency: <10, 10-14, and ≥15 days; (2) sample quartiles of the total cumulative hours of headache: <140, 140 to <280, 280 to <420, and ≥420 hours. Two sets of responsiveness categories were defined as reduction of <30%, 30% to <50%, or ≥50% in (1) number of headache days and (2) cumulative hours of headache. Measurement invariance tests supported the stability of the HIT-6 latent structure across studies. DIF analysis supported cross-cultural comparability. Good reliability was observed across studies (Cronbach's α: 0.75-0.92; intraclass correlation coefficient: 0.76-0.80). HIT-6 scores correlated strongly (-0.86 to -0.59) with scores of the Migraine-Specific Quality-of-Life Questionnaire. Analysis of variance indicated that HIT-6 scores discriminated across both types of criterion groups (P<0.001), across studies and time points. HIT-6 change scores were significantly higher in magnitude in groups experiencing greater improvement (P<0.001). All measurement properties were consistently verified across the two studies, supporting the validity of the HIT-6 among chronic migraine patients. NCT00156910 and NCT00168428 on www.ClinicalTrials.gov.
Abdolahi, Amir; Scoglio, Nicholas; Killoran, Annie; Dorsey, Ray; Biglan, Kevin M.
2013-01-01
Background By permitting remote assessments of patients and research participants, telemedicine has the potential to reshape clinical care and clinical trials for Parkinson disease. While the majority of the motor Unified Parkinson’s Disease Rating Scale (UPDRS) items can be conducted visually, rigidity and retropulsion pull testing require hands-on assessment by the rater and are less feasible to perform remotely in patients' homes. Methods In a secondary data analysis of the Comparison of the Agonist pramipexole vs. Levodopa on Motor complications in Parkinson’s Disease (CALM-PD) study, a randomized clinical trial, we assessed the cross-sectional (baseline and 2 years) and longitudinal (change from baseline to 2 years) reliability of a modified motor UPDRS (removing rigidity and retropulsion items) compared to the standard motor UPDRS (all items) using intraclass correlation coefficients (ICC), stratified by treatment group. Internal consistency of the modified UPDRS (mUPDRS) was measured using Cronbach’s alpha, and concurrent validity was assessed using Pearson’s correlation coefficient (r) between the standard motor UPDRS and mUPDRS. Results The mUPDRS versus standard motor UPDRS is cross-sectionally (ICC ≥ 0.92) and longitudinally (ICC ≥ 0.92) reliable for both treatment groups. High internal consistencies were also observed (α ≥ 0.96). The mUPDRS had high concurrent validity with the standard UPDRS at both time points and longitudinally (r ≥ 0.93, p < 0.0001). Conclusions A modified version of the motor UPDRS without rigidity and retropulsion pull testing is reliable and valid and may lay the foundation for its use in remote assessments of patients and research participants. PMID:23102808
Abdolahi, Amir; Scoglio, Nicholas; Killoran, Annie; Dorsey, E Ray; Biglan, Kevin M
2013-02-01
By permitting remote assessments of patients and research participants, telemedicine has the potential to reshape clinical care and clinical trials for Parkinson disease. While the majority of the motor Unified Parkinson's Disease Rating Scale (UPDRS) items can be conducted visually, rigidity and retropulsion pull testing require hands-on assessment by the rater and are less feasible to perform remotely in patients' homes. In a secondary data analysis of the Comparison of the Agonist pramipexole vs. Levodopa on Motor complications in Parkinson's Disease (CALM-PD) study, a randomized clinical trial, we assessed the cross-sectional (baseline and 2 years) and longitudinal (change from baseline to 2 years) reliability of a modified motor UPDRS (removing rigidity and retropulsion items) compared to the standard motor UPDRS (all items) using intraclass correlation coefficients (ICC), stratified by treatment group. Internal consistency of the modified UPDRS (mUPDRS) was measured using Cronbach's alpha, and concurrent validity was assessed using Pearson's correlation coefficient (r) between the standard motor UPDRS and mUPDRS. The mUPDRS versus standard motor UPDRS is cross-sectionally (ICC ≥ 0.92) and longitudinally (ICC ≥ 0.92) reliable for both treatment groups. High internal consistencies were also observed (α ≥ 0.96). The mUPDRS had high concurrent validity with the standard UPDRS at both time points and longitudinally (r ≥ 0.93, p < 0.0001). A modified version of the motor UPDRS without rigidity and retropulsion pull testing is reliable and valid and may lay the foundation for its use in remote assessments of patients and research participants. Copyright © 2012 Elsevier Ltd. All rights reserved.
Stikic, Maja; Berka, Chris; Levendowski, Daniel J.; Rubio, Roberto F.; Tan, Veasna; Korszen, Stephanie; Barba, Douglas; Wurzer, David
2014-01-01
The objective of this study was to investigate the feasibility of physiological metrics such as ECG-derived heart rate and EEG-derived cognitive workload and engagement as potential predictors of performance on different training tasks. An unsupervised approach based on self-organizing neural network (NN) was utilized to model cognitive state changes over time. The feature vector comprised EEG-engagement, EEG-workload, and heart rate metrics, all self-normalized to account for individual differences. During the competitive training process, a linear topology was developed where the feature vectors similar to each other activated the same NN nodes. The NN model was trained and auto-validated on combat marksmanship training data from 51 participants that were required to make “deadly force decisions” in challenging combat scenarios. The trained NN model was cross validated using 10-fold cross-validation. It was also validated on a golf study in which additional 22 participants were asked to complete 10 sessions of 10 putts each. Temporal sequences of the activated nodes for both studies followed the same pattern of changes, demonstrating the generalization capabilities of the approach. Most node transition changes were local, but important events typically caused significant changes in the physiological metrics, as evidenced by larger state changes. This was investigated by calculating a transition score as the sum of subsequent state transitions between the activated NN nodes. Correlation analysis demonstrated statistically significant correlations between the transition scores and subjects' performances in both studies. This paper explored the hypothesis that temporal sequences of physiological changes comprise the discriminative patterns for performance prediction. These physiological markers could be utilized in future training improvement systems (e.g., through neurofeedback), and applied across a variety of training environments. PMID:25414629
Huang, Hongshi; Zhang, Dongxia; Jiang, Yanfang; Yang, Jie; Feng, Tao; Gong, Xi; Wang, Jianquan; Ao, Yingfang
2016-01-01
To translate the English version of Tegner Activity Score into a Simplified-Chinese version (Tegner-C) and evaluate its psychometric properties. Tegner-C was cross-culturally adapted according to established guidelines. The validity and reliability of Tegner-C were assessed in 78 participants, with 19-20 participants in each of the four groups: before anterior cruciate ligament reconstruction (pre-ACLR) group, 2-3 months after ACLR group, 3-12 months after ACLR group, and healthy control group. Each participant was asked to complete the Tegner-C and Chinese version of International Knee Documentation Committee Subjective Knee Form (IKDC-SKF-C) twice, with an interval of 5±2 days. Intra-class correlation coefficient (ICC2, 1) was used to assess the reliability and Spearman's rank correlation was used for construct validity. The ICC2,1 was higher than 0.90 for all groups except in the pre-ACLR group, for which the ICC2,1 was 0.71 (0.41, 0.87) (All with p<0.001). The absolute reliability as evaluated by the smallest detectable change was 0.43, 2.12, 0.89, and 0.44 for the healthy control group, pre-ACLR group, 2-3 months after ACLR group, and 3-12 months after ACLR group, respectively. Neither a ceiling effect nor a floor effect was observed for any group. Significant difference was observed for both Tegner-C and IKDC-SKF-C scores between the control and the other three groups (all with p<0.001), and between pre-ACLR and the 2-3 months after ACLR group (p<0.001). Tegner-C demonstrated comparable psychometric properties to the original English version and thus is reliable and valid for Chinese-speaking patients with ACL injury.
NASA Astrophysics Data System (ADS)
Vasterling, Margarete; Wegler, Ulrich; Bruestle, Andrea; Becker, Jan
2016-04-01
Real time information on the locations and magnitudes of induced earthquakes is essential for response plans based on the magnitude frequency distribution. We developed and tested a real time cross-correlation detector focusing on induced microseismicity in deep geothermal reservoirs. The incoming seismological data are cross-correlated in real time with a set of known master events. We use the envelopes of the seismograms rather than the seismograms themselves to account for small changes in the source locations or in the focal mechanisms. Two different detection conditions are implemented: After first passing a single trace correlation condition, secondly a network correlation is calculated taking the amplitude information of the seismic network into account. The magnitude is estimated by using the respective ratio of the maximum amplitudes of the master event and the detected event. The detector is implemented as a real time tool and put into practice as a SeisComp3 module, an established open source software for seismological real time data handling and analysis. We validated the reliability and robustness of the detector by an offline playback test using four month of data from monitoring the power plant in Insheim (Upper Rhine Graben, SW Germany). Subsequently, in October 2013 the detector was installed as real time monitoring system within the project "MAGS2 - Microseismic Activity of Geothermal Systems". Master events from the two neighboring geothermal power plants in Insheim and Landau and two nearby quarries are defined. After detection, manual phase determination and event location are performed at the local seismological survey of the Geological Survey and Mining Authority of Rhineland-Palatinate. Until November 2015 the detector identified 454 events out of which 95% were assigned correctly to the respective source. 5% were misdetections caused by local tectonic events. To evaluate the completeness of the automatically obtained catalogue, it is compared to the event catalogue of the Seismological Service of Southwestern Germany and to the events reported by the company tasked with seismic monitoring of the Insheim power plant. Events missed by the cross-correlation detector are generally very small. They are registered at too few stations to meet the detection criteria. Most of these small events were not locatable. The automatic catalogue has a magnitude of completeness around 0.0 and is significantly more detailed than the catalogue from standard processing of the Seismological Service of Southwestern Germany for this region. For events in the magnitude range of the master event the magnitude estimated from the amplitude ratio reproduces the local magnitude well. For weaker events there tends to be a small offset. Altogether, the developed real time cross correlation detector provides robust detections with reliable association of the events to the respective sources and valid magnitude estimates. Thus, it provides input parameters for the mitigation of seismic hazard by using response plans in real time.
KiDS-450: tomographic cross-correlation of galaxy shear with Planck lensing
NASA Astrophysics Data System (ADS)
Harnois-Déraps, Joachim; Tröster, Tilman; Chisari, Nora Elisa; Heymans, Catherine; van Waerbeke, Ludovic; Asgari, Marika; Bilicki, Maciej; Choi, Ami; Erben, Thomas; Hildebrandt, Hendrik; Hoekstra, Henk; Joudaki, Shahab; Kuijken, Konrad; Merten, Julian; Miller, Lance; Robertson, Naomi; Schneider, Peter; Viola, Massimo
2017-10-01
We present the tomographic cross-correlation between galaxy lensing measured in the Kilo Degree Survey (KiDS-450) with overlapping lensing measurements of the cosmic microwave background (CMB), as detected by Planck 2015. We compare our joint probe measurement to the theoretical expectation for a flat Λ cold dark matter cosmology, assuming the best-fitting cosmological parameters from the KiDS-450 cosmic shear and Planck CMB analyses. We find that our results are consistent within 1σ with the KiDS-450 cosmology, with an amplitude re-scaling parameter AKiDS = 0.86 ± 0.19. Adopting a Planck cosmology, we find our results are consistent within 2σ, with APlanck = 0.68 ± 0.15. We show that the agreement is improved in both cases when the contamination to the signal by intrinsic galaxy alignments is accounted for, increasing A by ∼0.1. This is the first tomographic analysis of the galaxy lensing - CMB lensing cross-correlation signal, and is based on five photometric redshift bins. We use this measurement as an independent validation of the multiplicative shear calibration and of the calibrated source redshift distribution at high redshifts. We find that constraints on these two quantities are strongly correlated when obtained from this technique, which should therefore not be considered as a stand-alone competitive calibration tool.
Stoll, Kathrin; Hauck, Yvonne; Downe, Soo; Edmonds, Joyce; Gross, Mechthild M; Malott, Anne; McNiven, Patricia; Swift, Emma; Thomson, Gillian; Hall, Wendy A
2016-06-01
Assessment of childbirth fear, in advance of pregnancy, and early identification of modifiable factors contributing to fear can inform public health initiatives and/or school-based educational programming for the next generation of maternity care consumers. We developed and evaluated a short fear of birth scale that incorporates the most common dimensions of fear reported by men and women prior to pregnancy, fear of: labour pain, being out of control and unable to cope with labour and birth, complications, and irreversible physical damage. University students in six countries (Australia, Canada, England, Germany, Iceland, and the United States, n = 2240) participated in an online survey to assess their fears and attitudes about birth. We report internal consistency reliability, corrected-item-to-total correlations, factor loadings and convergent and discriminant validity of the new scale. The Childbirth Fear - Prior to Pregnancy (CFPP) scale showed high internal consistency across samples (α > 0.86). All corrected-item-to total correlations exceeded 0.45, supporting the uni-dimensionality of the scale. Construct validity of the CFPP was supported by a high correlation between the new scale and a two-item visual analogue scale that measures fear of birth (r > 0.6 across samples). Weak correlations of the CFPP with scores on measures that assess related psychological states (anxiety, depression and stress) support the discriminant validity of the scale. The CFPP is a short, reliable and valid measure of childbirth fear among young women and men in six countries who plan to have children. Copyright © 2016 Elsevier B.V. All rights reserved.
Naja, Farah; Hwalla, Nahla; Fossian, Talar; Zebian, Dina; Nasreddine, Lara
2015-02-01
To assess the validity and reliability of the Arabic version of the Household Food Insecurity Access Scale (HFIAS) in rural Lebanon. A cross-sectional study on a sample of households with at least one child aged 0-2 years. In a one-to-one interview, participants completed an adapted Arabic version of the HFIAS. In order to evaluate the validity of the HFIAS, basic sociodemographic information, anthropometric measurements of the mother and child, and dietary intake data of the child were obtained. In order to examine reproducibility, the HFIAS was re-administered after 3 months. Rural Lebanon. Mother and child pairs (n 150). Factor analysis of HFIAS items revealed two factors: 'insufficient food quality' and 'insufficient food quantity'. Using Pearson's correlation, food insecurity was inversely associated with mother's and father's education levels, number of cars and electrical appliances in the household, income, weight-for-age and length-for-age of the child and the child's dietary adequacy. In contrast, mother's BMI and crowding index were positively associated with food insecurity scores (P < 0·05 for all correlations). Cronbach's α of the scale was 0·91. A moderate correlation was observed between the two administrations of the questionnaire (intra-class correlation = 0·58; P < 0·05). Our findings indicated that the adapted Arabic version of the HFIAS is a valid and reliable tool to assess food insecurity in rural Lebanon, lending further evidence to the utility of the HFIAS in assessing food insecurity in culturally diverse populations.
The validity and reliability of the ADL-Glittre test for children.
Martins, Renata; Assumpção, Maíra S de; Bobbio, Tatiana G; Mayer, Anamaria F; Schivinski, Camila
2018-04-16
The ADL-Glittre was created to assess more comprehensively the essential activities of daily living in adults with chronic obstructive pulmonary disease. The aim of this study was to validate the ADL-Glittre test adapted for children (TGlittre-P) and verify its reliability. This is a cross-sectional study with 87 healthy children aged 6 to 14 years (mean 10.36 ± 2.32 years). Biometric and spirometry data were collected from all participants. On the same day, part of the sample (36 children included in the validation process) performed two 6MWT and two TGlittre-P (30-minute interval between them). The other part of the sample just performed two TGlittre-P for the reliability process. Pearson and Spearman correlation tests were used to verify the correlation between the time spent on the TGlittre-P and the distance walked in the 6MWT. The intraclass correlation coefficient (ICC) was also used to assess the reproducibility of the TGlittre-P. The TGlittre-P showed a moderate negative correlation with the 6MWT (r = -0.490; p = 0.002; 95%CI -0.712 to -0.233). However, the behavior of the physiological variables that were monitored during the tests was similar and showed to be reproducible (ICC = 0.843; p = 0.000; 95%CI 0.695 to 0.911). The TGlittre-P proved to be a valid and reliable assessment of the functional capacity of healthy children aged 6 to 14 years.
Sobański, Jerzy A; Klasa, Katarzyna; Rutkowski, Krzysztof; Dembińska, Edyta; Müldner-Nieckowski, Łukasz; Cyranka, Katarzyna
2013-01-01
Assessment of reliability, cross-validity and usefulness in everyday clinical practice of two related tools: Social Avoidance and Distress Scale (SAD) and Fear of Negative Evaluation Scale (FNE). Analysis of tests results of 453 females and 172 males diagnosed in the years 2008-2010 in the Outpatient Clinic for Neurotic and Behavioral Disorders of the Cracow University Hospital, including, inter alia, results of the questionnaires SAD and FNE. The scales have been, with the consent of their authors (R. Friend) and the copyright holder (APA), translated into Polish and back-translated. Subjects also completed the symptom checklist KO '0'(n = 512), and neurotic personality questionnaire KON-2006 (n = 505), as well as the NEO-PI-R personality inventory (n = 46). The reliability and cross-validity coefficients of Polish versions were assessed in the patient population and their results were compared with those of the group of 75 medical students. The translation was verified by retranslation. The reliability coefficients of Polish version of the SAD and FNE scales turned out to be high--Cronbach's alpha coefficient was 0.94 for both scales, Guttman's split-half reliability coefficient 0.93. Correlations with symptom checklist KO '0 'and neurotic personality questionnaire KON-2006, as well as with the NEO -PI-R personality inventory were significant and indicate a good cross-validity of the analyzed tools. The average results in the patient population for both scales were significantly higher than the results in the preliminary control group of medical students. Polish versions of SAD and FNE questionnaires, like their other translations from English, proved to be reliable and have a high cross-validity with other original Polish tools used in the diagnosis of neurotic disorders, which allows to recommend them to be used in further studies, also in comparing healthy persons with those suffering from a variety of neurotic disorders.
NASA Astrophysics Data System (ADS)
Li, Zuhe; Fan, Yangyu; Liu, Weihua; Yu, Zeqi; Wang, Fengqin
2017-01-01
We aim to apply sparse autoencoder-based unsupervised feature learning to emotional semantic analysis for textile images. To tackle the problem of limited training data, we present a cross-domain feature learning scheme for emotional textile image classification using convolutional autoencoders. We further propose a correlation-analysis-based feature selection method for the weights learned by sparse autoencoders to reduce the number of features extracted from large size images. First, we randomly collect image patches on an unlabeled image dataset in the source domain and learn local features with a sparse autoencoder. We then conduct feature selection according to the correlation between different weight vectors corresponding to the autoencoder's hidden units. We finally adopt a convolutional neural network including a pooling layer to obtain global feature activations of textile images in the target domain and send these global feature vectors into logistic regression models for emotional image classification. The cross-domain unsupervised feature learning method achieves 65% to 78% average accuracy in the cross-validation experiments corresponding to eight emotional categories and performs better than conventional methods. Feature selection can reduce the computational cost of global feature extraction by about 50% while improving classification performance.
A signature correlation study of ground target VHF/UHF ISAR imagery
NASA Astrophysics Data System (ADS)
Gatesman, Andrew J.; Beaudoin, Christopher J.; Giles, Robert H.; Kersey, William T.; Waldman, Jerry; Carter, Steve; Nixon, William E.
2003-09-01
VV and HH-polarized radar signatures of several ground targets were acquired in the VHF/UHF band (171-342 MHz) by using 1/35th scale models and an indoor radar range operating from 6 to 12 GHz. Data were processed into medianized radar cross sections as well as focused, ISAR imagery. Measurement validation was confirmed by comparing the radar cross section of a test object with a method of moments radar cross section prediction code. The signatures of several vehicles from three vehicle classes (tanks, trunks, and TELs) were measured and a signature cross-correlation study was performed. The VHF/UHF band is currently being exploited for its foliage penetration ability, however, the coarse image resolution which results from the relatively long radar wavelengths suggests a more challenging target recognition problem. One of the study's goals was to determine the amount of unique signature content in VHF/UHF ISAR imagery of military ground vehicles. Open-field signatures are compared with each other as well as with simplified shapes of similar size. Signatures were also acquired on one vehicle in a variety of configurations to determine the impact of monitor target variations on the signature content at these frequencies.
Hu, Liya; Li, Jingwen; Wang, Xu; Payne, Sheila; Chen, Yuan; Mei, Qi
2015-11-01
The validation of McGill quality-of-life questionnaire (MQOLQ) in mainland China, which had already been used in multicultural palliative care background including Hong Kong and Taiwan, remained unknown. Eligible patients completed the translated Chinese version of McGill questionnaires (MQOL-C), which had been examined before the study. Construct validity was preliminarily assessed through exploratory factor analysis extracting 4 factors that construct a new hypothesis model and then the original model was proved to be better confirmed by confirmatory factor analysis. Internal consistency of all the subscales was within 0.582 to 0.917. Furthermore, test-retest reliability ranged from 0.509 to 0.859, which was determined by Spearman rank correlation coefficient. Face validation and feasibility also confirm the good validity of MQOL-C. The MQOL-C has satisfied validation in mainland Chinese patients with cancer, although cultural difference should be considered while using it. © The Author(s) 2014.
NASA Astrophysics Data System (ADS)
Chen, Bohong; Zhu, Zhibo; Chen, Min; Dong, Wenqi; Li, Zhen
2014-03-01
A comparative molecular similarity indices analysis (CoMSIA) was performed on a set of 27 curcumin-like diarylpentanoid analogues with the radical scavenging activities. A significant cross-validated correlation coefficient Q2 (0.784), SEP (0.042) for CoMSIA were obtained, indicating the statistical significance of the correlation. Further we adopt a rational approach toward the selection of substituents at various positions in our scaffold,and finally find the favored and disfavoured regions for the enhanced antioxidative activity. The results have been used as a guide to design compounds that, potentially, have better activity against oxidative damage.
NASA Astrophysics Data System (ADS)
Davis, C.; Rozo, E.; Roodman, A.; Alarcon, A.; Cawthon, R.; Gatti, M.; Lin, H.; Miquel, R.; Rykoff, E. S.; Troxel, M. A.; Vielzeuf, P.; Abbott, T. M. C.; Abdalla, F. B.; Allam, S.; Annis, J.; Bechtol, K.; Benoit-Lévy, A.; Bertin, E.; Brooks, D.; Buckley-Geer, E.; Burke, D. L.; Carnero Rosell, A.; Carrasco Kind, M.; Carretero, J.; Castander, F. J.; Crocce, M.; Cunha, C. E.; D'Andrea, C. B.; da Costa, L. N.; Desai, S.; Diehl, H. T.; Doel, P.; Drlica-Wagner, A.; Fausti Neto, A.; Flaugher, B.; Fosalba, P.; Frieman, J.; García-Bellido, J.; Gaztanaga, E.; Gerdes, D. W.; Giannantonio, T.; Gruen, D.; Gruendl, R. A.; Gutierrez, G.; Honscheid, K.; Jain, B.; James, D. J.; Jeltema, T.; Krause, E.; Kuehn, K.; Kuhlmann, S.; Kuropatkin, N.; Lahav, O.; Li, T. S.; Lima, M.; March, M.; Marshall, J. L.; Martini, P.; Melchior, P.; Ogando, R. L. C.; Plazas, A. A.; Romer, A. K.; Sanchez, E.; Scarpine, V.; Schindler, R.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, M.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Vikram, V.; Walker, A. R.; Wechsler, R. H.
2018-06-01
Galaxy cross-correlations with high-fidelity redshift samples hold the potential to precisely calibrate systematic photometric redshift uncertainties arising from the unavailability of complete and representative training and validation samples of galaxies. However, application of this technique in the Dark Energy Survey (DES) is hampered by the relatively low number density, small area, and modest redshift overlap between photometric and spectroscopic samples. We propose instead using photometric catalogues with reliable photometric redshifts for photo-z calibration via cross-correlations. We verify the viability of our proposal using redMaPPer clusters from the Sloan Digital Sky Survey (SDSS) to successfully recover the redshift distribution of SDSS spectroscopic galaxies. We demonstrate how to combine photo-z with cross-correlation data to calibrate photometric redshift biases while marginalizing over possible clustering bias evolution in either the calibration or unknown photometric samples. We apply our method to DES Science Verification (DES SV) data in order to constrain the photometric redshift distribution of a galaxy sample selected for weak lensing studies, constraining the mean of the tomographic redshift distributions to a statistical uncertainty of Δz ˜ ±0.01. We forecast that our proposal can, in principle, control photometric redshift uncertainties in DES weak lensing experiments at a level near the intrinsic statistical noise of the experiment over the range of redshifts where redMaPPer clusters are available. Our results provide strong motivation to launch a programme to fully characterize the systematic errors from bias evolution and photo-z shapes in our calibration procedure.
Davis, C.; Rozo, E.; Roodman, A.; ...
2018-03-26
Galaxy cross-correlations with high-fidelity redshift samples hold the potential to precisely calibrate systematic photometric redshift uncertainties arising from the unavailability of complete and representative training and validation samples of galaxies. However, application of this technique in the Dark Energy Survey (DES) is hampered by the relatively low number density, small area, and modest redshift overlap between photometric and spectroscopic samples. We propose instead using photometric catalogs with reliable photometric redshifts for photo-z calibration via cross-correlations. We verify the viability of our proposal using redMaPPer clusters from the Sloan Digital Sky Survey (SDSS) to successfully recover the redshift distribution of SDSS spectroscopic galaxies. We demonstrate how to combine photo-z with cross-correlation data to calibrate photometric redshift biases while marginalizing over possible clustering bias evolution in either the calibration or unknown photometric samples. We apply our method to DES Science Verification (DES SV) data in order to constrain the photometric redshift distribution of a galaxy sample selected for weak lensing studies, constraining the mean of the tomographic redshift distributions to a statistical uncertainty ofmore » $$\\Delta z \\sim \\pm 0.01$$. We forecast that our proposal can in principle control photometric redshift uncertainties in DES weak lensing experiments at a level near the intrinsic statistical noise of the experiment over the range of redshifts where redMaPPer clusters are available. Here, our results provide strong motivation to launch a program to fully characterize the systematic errors from bias evolution and photo-z shapes in our calibration procedure.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, C.; Rozo, E.; Roodman, A.
Galaxy cross-correlations with high-fidelity redshift samples hold the potential to precisely calibrate systematic photometric redshift uncertainties arising from the unavailability of complete and representative training and validation samples of galaxies. However, application of this technique in the Dark Energy Survey (DES) is hampered by the relatively low number density, small area, and modest redshift overlap between photometric and spectroscopic samples. We propose instead using photometric catalogs with reliable photometric redshifts for photo-z calibration via cross-correlations. We verify the viability of our proposal using redMaPPer clusters from the Sloan Digital Sky Survey (SDSS) to successfully recover the redshift distribution of SDSS spectroscopic galaxies. We demonstrate how to combine photo-z with cross-correlation data to calibrate photometric redshift biases while marginalizing over possible clustering bias evolution in either the calibration or unknown photometric samples. We apply our method to DES Science Verification (DES SV) data in order to constrain the photometric redshift distribution of a galaxy sample selected for weak lensing studies, constraining the mean of the tomographic redshift distributions to a statistical uncertainty ofmore » $$\\Delta z \\sim \\pm 0.01$$. We forecast that our proposal can in principle control photometric redshift uncertainties in DES weak lensing experiments at a level near the intrinsic statistical noise of the experiment over the range of redshifts where redMaPPer clusters are available. Here, our results provide strong motivation to launch a program to fully characterize the systematic errors from bias evolution and photo-z shapes in our calibration procedure.« less
Planar spatial correlations, anisotropy, and specific surface area of stationary random porous media
NASA Astrophysics Data System (ADS)
Berryman, James G.
1998-02-01
An earlier result of the author showed that an anisotropic spatial correlation function of a random porous medium could be used to compute the specific surface area when it is stationary as well as anisotropic by first performing a three-dimensional radial average and then taking the first derivative with respect to lag at the origin. This result generalized the earlier result for isotropic porous media of Debye et al. [J. Appl. Phys. 28, 679 (1957)]. The present article provides more detailed information about the use of spatial correlation functions for anisotropic porous media and in particular shows that, for stationary anisotropic media, the specific surface area can be related to the derivative of the two-dimensional radial average of the correlation function measured from cross sections taken through the anisotropic medium. The main concept is first illustrated using a simple pedagogical example for an anisotropic distribution of spherical voids. Then, a general derivation of formulas relating the derivative of the planar correlation functions to surface integrals is presented. When the surface normal is uniformly distributed (as is the case for any distribution of spherical voids), our formulas can be used to relate a specific surface area to easily measurable quantities from any single cross section. When the surface normal is not distributed uniformly (as would be the case for an oriented distribution of ellipsoidal voids), our results show how to obtain valid estimates of specific surface area by averaging measurements on three orthogonal cross sections. One important general observation for porous media is that the surface area from nearly flat cracks may be underestimated from measurements on orthogonal cross sections if any of the cross sections happen to lie in the plane of the cracks. This result is illustrated by taking the very small aspect ratio (penny-shaped crack) limit of an oblate spheroid, but holds for other types of flat surfaces as well.
Planar spatial correlations, anisotropy, and specific surface area of stationary random porous media
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berryman, J.G.
1998-02-01
An earlier result of the author showed that an anisotropic spatial correlation function of a random porous medium could be used to compute the specific surface area when it is stationary as well as anisotropic by first performing a three-dimensional radial average and then taking the first derivative with respect to lag at the origin. This result generalized the earlier result for isotropic porous media of Debye {ital et al.} [J. Appl. Phys. {bold 28}, 679 (1957)]. The present article provides more detailed information about the use of spatial correlation functions for anisotropic porous media and in particular shows that,more » for stationary anisotropic media, the specific surface area can be related to the derivative of the two-dimensional radial average of the correlation function measured from cross sections taken through the anisotropic medium. The main concept is first illustrated using a simple pedagogical example for an anisotropic distribution of spherical voids. Then, a general derivation of formulas relating the derivative of the planar correlation functions to surface integrals is presented. When the surface normal is uniformly distributed (as is the case for any distribution of spherical voids), our formulas can be used to relate a specific surface area to easily measurable quantities from any single cross section. When the surface normal is not distributed uniformly (as would be the case for an oriented distribution of ellipsoidal voids), our results show how to obtain valid estimates of specific surface area by averaging measurements on three orthogonal cross sections. One important general observation for porous media is that the surface area from nearly flat cracks may be underestimated from measurements on orthogonal cross sections if any of the cross sections happen to lie in the plane of the cracks. This result is illustrated by taking the very small aspect ratio (penny-shaped crack) limit of an oblate spheroid, but holds for other types of flat surfaces as well.« less
De Smedt, Delphine; Clays, Els; Doyle, Frank; Kotseva, Kornelia; Prugger, Christof; Pająk, Andrzej; Jennings, Catriona; Wood, David; De Bacquer, Dirk
2013-09-01
To investigate the validity and reliability of the EuroQol-5D (EQ-5D), the 12-item Short-Form Health Survey (SF-12v2), and the Hospital Anxiety and Depression Scale (HADS) in a stable coronary population. Cross-sectional study EUROASPIRE III. Quality of life data (QoL) were available on 8745 patients hospitalized for coronary artery bypass graft (CABG), percutaneous coronary intervention (PCI), acute myocardial infarction (AMI), or myocardial ischemia. They were interviewed and examined at least 6 months after their hospital admission. Reliability and validity of the 3 instruments were tested. Internal consistency, and discriminative, convergent, criterion and construct validity were assessed. Cronbach's alpha indicated good internal consistency for all measures (0.73 to 0.87). Discriminative validity analyses confirmed significant QoL differences between known groups: age, gender, educational level. In addition, all hypothesized correlations between QoL constructs (convergent validity) and items (criterion validity) were confirmed with significant correlations. Confirmatory factor analyses indicated good construct validity for HADS and SF-12v2. On country-specific level, results were roughly similar. The EQ-5D as well as the SF-12v2 and the HADS are reliable and valid instruments for use in a stable coronary population, both on aggregate European level and on country-specific level. However, our results must be generalized with caution, because EUROASPIRE III patients might not be representative for all patients with stable coronary heart disease. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Negahban, Hossein; Mohtasebi, Elham; Goharpey, Shahin
2015-01-01
The aim of this methodological study was to cross-culturally translate the Shoulder Activity Scale (SAS) into the Persian and determine its clinimetric properties including reliability, validity, and responsiveness in patients with shoulder disorders. Persian version of the SAS was obtained after standard forward-backward translation. Three questionnaires were completed by the respondents: SAS, shoulder pain and disability index (SPADI), and Short-Form 36 Health Survey (SF-36). The patients completed the SAS, 1 week after the first visit to evaluate the test-retest reliability. Construct validity was evaluated by examining the associations between the scores on the SAS and the scores obtained from the SPADI, SF-36, and age of the patients. To assess responsiveness, data were collected in the first visit and then again after 4 weeks physiotherapy intervention. Test-retest reliability and internal consistency were assessed using Intra-class Correlation Coefficient (ICC) and Cronbach's alpha, respectively. To evaluate construct validity, Spearman's rank correlation was used. The ability of the SAS to detect changes was evaluated by the receiver-operating characteristics method. No problem or language difficulties were reported during translation process. Test-retest reliability of the SAS was excellent with an ICC of 0.98. Also, the marginal Cronbach's alpha level of 0.64 was obtained. The correlation between the SAS and the SPADI was low, proving divergent validity, whereas the correlations between the SAS and the SF-36/age were moderate proving convergent validity. A marginally acceptable responsiveness was achieved for the Persian SAS. The study provides some evidences to support the test-retest reliability, internal consistency, construct validity, and responsiveness of the Persian version of the SAS in patients with shoulder disorders. Therefore, it seems that this instrument is a useful measure of shoulder activity level in research setting and clinical practice. The shoulder activity scale (SAS) is a reliable, valid, and responsive measure of shoulder activity level in Persian-speaking patients with different shoulder disorders. The results on clinimetric properties of the Persian SAS are comparable with its original, English version. Persian version of the SAS can be used in "clinical" and "research" settings of patients with shoulder disorders.
Khairullah, Shasha; Mahadeva, Sanjiv
2017-01-01
Objective We aimed to adapt, translate and validate the Chronic Liver Disease Questionnaire (CLDQ) in Malaysian patients with chronic liver diseases of various aetiologies. Setting Tertiary level teaching institution in Malaysia. Participants The validation process involved 211 adult patients (English language n=101, Malay language n=110) with chronic liver disease. Characteristics of the study subjects were as follows: mean (SD) age was 56 (12.8) years, 58.3% were male and 41.7% female. The inclusion criteria were patients 18 years or older with chronic hepatitis and/or liver cirrhosis of any aetiology. The exclusion criteria were as follows: presence of hepatic encephalopathy, ongoing treatment with interferon and presence of other chronic conditions that have an impact on health-related quality of life (HRQOL). Methods A cross-sectional study was conducted. Cultural adaptation of the English version of the CLDQ was performed, and a Malay version was developed following standard forward–backward translation by independent native speakers. Psychometric properties of both versions were determined by assessing their internal consistency, test–retest reliability and discriminant and convergent validity. Results Cronbach’s alpha for internal consistency across the various domains of the CLDQ was 0.95 for the English version and 0.92 for the Malay version. Test–retest analysis showed excellent reliability with an intraclass correlation coefficient of 0.89 for the English version and 0.93 for the Malay version. The average scores of both the English and Malay versions of the CLDQ demonstrated adequate discriminant validity by differentiating between non-cirrhosis (English 6.3, Malay 6.1), compensated cirrhosis (English 5.6, Malay 6.0) and decompensated cirrhosis (English 5.1, Malay 4.9) (p<0.001). Convergent validity showed that correlation was fair between the English (ρ=0.59) and Malay (p=0.47) CLDQ versions with the EQ-5D, a generic HRQOL instrument. Conclusion The English and Malay versions of the CLDQ are reliable and valid disease-specific instruments for assessing HRQOL in Malaysian patients with chronic liver disease. PMID:28550020
2012-01-01
Background Preventive child health care is well suited for the early detection of parenting and developmental problems. However, as far as the younger age group is concerned, there are no validated early detection instruments which cover both the child and its environment. Therefore, we have developed a broad-scope structured interview which assesses parents’ concerns and their need for support, using both the parental perspective and the experience of the child health care nurse: the Structured Problem Analysis of Raising Kids (SPARK). This study reports the psychometric characteristics of the SPARK. Method A cross-sectional study of 2012 18-month-old children, living in Zeeland, a province of the Netherlands. Inter-rater reliability was assessed in 67 children. Convergent validity was assessed by comparing SPARK-domains with domains in self-report questionnaires on child development and parenting stress. Discriminative validity was assessed by comparing different outcomes of the SPARK between groups with different levels of socio-economic status and by performing an extreme-groups comparison. The user experience of both parents and nurses was assessed with the aid of an online survey. Results The response rate was 92.1% for the SPARK. Self-report questionnaires were returned in the case of 66.9% of the remaining 1721 children. There was selective non-reporting: 33.1% of the questionnaires were not returned, covering 65.2% of the children with a high-risk label according to the SPARK (p < 0.001). Inter-rater reliability was good to excellent with intraclass correlations between 0.85 and 1.0 for physical topics; between 0.61 and 0.8 for social-emotional topics and 0.92 for the overall risk assessment. Convergent validity was unexpectedly low (all correlations ≤0.3) although the pattern was as expected. Discriminative validity was good. Users were satisfied with the SPARK and identified some topics for improvement. Conclusion The SPARK discriminates between children with a high, increased and low risk of parenting and developmental problems. It does so in a reliable way, but more research is needed on aspects of validity and in other populations. PMID:22697218
Study of photon correlation techniques for processing of laser velocimeter signals
NASA Technical Reports Server (NTRS)
Mayo, W. T., Jr.
1977-01-01
The objective was to provide the theory and a system design for a new type of photon counting processor for low level dual scatter laser velocimeter (LV) signals which would be capable of both the first order measurements of mean flow and turbulence intensity and also the second order time statistics: cross correlation auto correlation, and related spectra. A general Poisson process model for low level LV signals and noise which is valid from the photon-resolved regime all the way to the limiting case of nonstationary Gaussian noise was used. Computer simulation algorithms and higher order statistical moment analysis of Poisson processes were derived and applied to the analysis of photon correlation techniques. A system design using a unique dual correlate and subtract frequency discriminator technique is postulated and analyzed. Expectation analysis indicates that the objective measurements are feasible.
Cross-validation pitfalls when selecting and assessing regression and classification models.
Krstajic, Damjan; Buturovic, Ljubomir J; Leahy, David E; Thomas, Simon
2014-03-29
We address the problem of selecting and assessing classification and regression models using cross-validation. Current state-of-the-art methods can yield models with high variance, rendering them unsuitable for a number of practical applications including QSAR. In this paper we describe and evaluate best practices which improve reliability and increase confidence in selected models. A key operational component of the proposed methods is cloud computing which enables routine use of previously infeasible approaches. We describe in detail an algorithm for repeated grid-search V-fold cross-validation for parameter tuning in classification and regression, and we define a repeated nested cross-validation algorithm for model assessment. As regards variable selection and parameter tuning we define two algorithms (repeated grid-search cross-validation and double cross-validation), and provide arguments for using the repeated grid-search in the general case. We show results of our algorithms on seven QSAR datasets. The variation of the prediction performance, which is the result of choosing different splits of the dataset in V-fold cross-validation, needs to be taken into account when selecting and assessing classification and regression models. We demonstrate the importance of repeating cross-validation when selecting an optimal model, as well as the importance of repeating nested cross-validation when assessing a prediction error.
Development and Validation of a Daily Pain Catastrophizing Scale.
Darnall, Beth D; Sturgeon, John A; Cook, Karon F; Taub, Chloe J; Roy, Anuradha; Burns, John W; Sullivan, Michael; Mackey, Sean C
2017-09-01
To date, there is no validated measure for pain catastrophizing at the daily level. The Pain Catastrophizing Scale (PCS) is widely used to measure trait pain catastrophizing. We sought to develop and validate a brief, daily version of the PCS for use in daily diary studies to facilitate research on mechanisms of catastrophizing treatment, individual differences in self-regulation, and to reveal the nuanced relationships between catastrophizing, correlates, and pain outcomes. After adapting the PCS for daily use, we evaluated the resulting 14 items using 3 rounds of cognitive interviews with 30 adults with chronic pain. We refined and tested the final daily PCS in 3 independent, prospective, cross-sectional, observational validation studies conducted in a combined total of 519 adults with chronic pain who completed online measures daily for 14 consecutive days. For study 1 (N = 131), exploratory factor analysis revealed adequate fit and-unexpectedly-unidimensionality for item responses to the daily PCS. Study 2 (N = 177) correlations indicated adequate association with related constructs (anger, anxiety, pain intensity, depression). Similarly, results for study 3 (N = 211) revealed expected correlations for daily PCS and measures of daily constructs including physical activity, sleep, energy level, and positive affect. Results from complex/multilevel confirmatory factor analysis confirmed good fit to a unidimensional model. Scores on the daily PCS were statistically comparable with and more parsimonious than the full 14-item version. Next steps include evaluation of score validity in populations with medical diagnoses, greater demographic diversity, and in patients with acute pain. This article describes the development and validation of a daily PCS. This daily measure may facilitate research that aims to characterize pain mechanisms, individual differences in self-regulation, adaptation, and nuanced relationships between catastrophizing, correlates, and pain outcomes. Copyright © 2017 American Pain Society. Published by Elsevier Inc. All rights reserved.
A whole blood gene expression-based signature for smoking status
2012-01-01
Background Smoking is the leading cause of preventable death worldwide and has been shown to increase the risk of multiple diseases including coronary artery disease (CAD). We sought to identify genes whose levels of expression in whole blood correlate with self-reported smoking status. Methods Microarrays were used to identify gene expression changes in whole blood which correlated with self-reported smoking status; a set of significant genes from the microarray analysis were validated by qRT-PCR in an independent set of subjects. Stepwise forward logistic regression was performed using the qRT-PCR data to create a predictive model whose performance was validated in an independent set of subjects and compared to cotinine, a nicotine metabolite. Results Microarray analysis of whole blood RNA from 209 PREDICT subjects (41 current smokers, 4 quit ≤ 2 months, 64 quit > 2 months, 100 never smoked; NCT00500617) identified 4214 genes significantly correlated with self-reported smoking status. qRT-PCR was performed on 1,071 PREDICT subjects across 256 microarray genes significantly correlated with smoking or CAD. A five gene (CLDND1, LRRN3, MUC1, GOPC, LEF1) predictive model, derived from the qRT-PCR data using stepwise forward logistic regression, had a cross-validated mean AUC of 0.93 (sensitivity=0.78; specificity=0.95), and was validated using 180 independent PREDICT subjects (AUC=0.82, CI 0.69-0.94; sensitivity=0.63; specificity=0.94). Plasma from the 180 validation subjects was used to assess levels of cotinine; a model using a threshold of 10 ng/ml cotinine resulted in an AUC of 0.89 (CI 0.81-0.97; sensitivity=0.81; specificity=0.97; kappa with expression model = 0.53). Conclusion We have constructed and validated a whole blood gene expression score for the evaluation of smoking status, demonstrating that clinical and environmental factors contributing to cardiovascular disease risk can be assessed by gene expression. PMID:23210427
Papadopoulos, Costas; Constantinou, Antonis; Cheimonidou, Areti-Zoi; Stasinopoulos, Dimitrios
2017-04-01
To cross-culturally adapt and validate the Greek version of the Kujala anterior knee pain scale (KAKPS). The Greek KAKPS was translated from the original English version following standard forward and backward translation procedures. The survey was then conducted in clinical settings by a questionnaire comprising the Greek KAKPS and patellofemoral pain syndrome (PFPS) severity scale. A total of 130 (62 women and 68 men) Greek-reading patients between 18 and 45 years old with anterior knee pain (AKP) for at least four weeks were recruited from physical therapy clinics. To establish test-retest reliability, the patients were asked to complete the KAKPS at initial visit and 2-3 days after the initial visit. The Greek version of the PFPS severity scale was also administered once at initial visit. Internal consistency of the translated instrument was measured using Cronbach's α. An intraclass correlation coefficient was used to assess the test-retest reliability of the KAKPS. Concurrent validity was measured by correlating the KAKPS with the PFPS severity scale using Pearson's correlation coefficient. The results showed that the Greek KAKPS has good internal consistency (Cronbach's α = 0.942), test-retest reliability (ICC = 0.921) and concurrent validity (r > 0.7). This study has shown that the Greek KAKPS has good internal consistency, test-retest reliability and concurrent validity when correlated with the PFPS severity scale in adult patients with AKP for at least four weeks. Implications for rehabilitation The Greek version of the KAKPS has been found to be reliable and valid when used in adult patients with AKP for at least four weeks. The results of the psychometric characteristics were compatible with those of the original English version. The KAKPS could be applied in a Greek-speaking population to assess functional limitations and symptoms in patients aged 18-45 years old with AKP for at least four weeks.
Thillainayagam, Mahalakshmi; Anbarasu, Anand; Ramaiah, Sudha
2016-08-21
The computational studies namely molecular docking simulations and Comparative Molecular Field Analysis (CoMFA) are executed on series of 52 novel aryl chalcones derivatives using Plasmodium falciparum cysteine proteases (falcipain - 2) as vital target. In the present study, the correlation between different molecular field effects namely steric and electrostatic interactions and chemical structures to the inhibitory activities of novel aryl chalcone derivatives is inferred to perceive the major structural prerequisites for the rational design and development of potent and novel lead anti-malarial compound. The apparent binding conformations of all the compounds at the active site of falcipain - 2 and the hydrogen-bond interactions which could be used to modify the inhibitory activities are identified by using Surflex-dock study. Statistically significant CoMFA model has been developed with the cross-validated correlation coefficient (q(2)) of 0.912 and the non-cross-validated correlation coefficient (r(2)) of 0.901. Standard error of estimation (SEE) of 0.210, with the optimum number of components is ten. The predictability of the derived model is examined with a test set consists of sixteen compounds and the predicted r(2) value is found to be 0.924. The docking and QSAR study results confer crucial suggestions for the optimization of novel 1,3-diphenyl-2-propen-1-one derivatives and synthesis of effective anti- malarial compounds. Copyright © 2016 Elsevier Ltd. All rights reserved.
Wang, Yuan; Wu, Mingwei; Ai, Chunzhi; Wang, Yonghua
2015-01-01
Presently, 151 widely-diverse pyridinylimidazole-based compounds that show inhibitory activities at the TNF-α release were investigated. By using the distance comparison technique (DISCOtech), comparative molecular field analysis (CoMFA), and comparative molecular similarity index analysis (CoMSIA) methods, the pharmacophore models and the three-dimensional quantitative structure-activity relationships (3D-QSAR) of the compounds were explored. The proposed pharmacophore model, including two hydrophobic sites, two aromatic centers, two H-bond donor atoms, two H-bond acceptor atoms, and two H-bond donor sites characterizes the necessary structural features of TNF-α release inhibitors. Both the resultant CoMFA and CoMSIA models exhibited satisfactory predictability (with Q2 (cross-validated correlation coefficient) = 0.557, R2ncv (non-cross-validated correlation coefficient) = 0.740, R2pre (predicted correlation coefficient) = 0.749 and Q2 = 0.598, R2ncv = 0.767, R2pre = 0.860, respectively). Good consistency was observed between the 3D-QSAR models and the pharmacophore model that the hydrophobic interaction and hydrogen bonds play crucial roles in the mechanism of actions. The corresponding contour maps generated by these models provide more diverse information about the key intermolecular interactions of inhibitors with the surrounding environment. All these models have extended the understanding of imidazole-based compounds in the structure-activity relationship, and are useful for rational design and screening of novel 2-thioimidazole-based TNF-α release inhibitors. PMID:26307982
Wang, Yuan; Wu, Mingwei; Ai, Chunzhi; Wang, Yonghua
2015-08-25
Presently, 151 widely-diverse pyridinylimidazole-based compounds that show inhibitory activities at the TNF-α release were investigated. By using the distance comparison technique (DISCOtech), comparative molecular field analysis (CoMFA), and comparative molecular similarity index analysis (CoMSIA) methods, the pharmacophore models and the three-dimensional quantitative structure-activity relationships (3D-QSAR) of the compounds were explored. The proposed pharmacophore model, including two hydrophobic sites, two aromatic centers, two H-bond donor atoms, two H-bond acceptor atoms, and two H-bond donor sites characterizes the necessary structural features of TNF-α release inhibitors. Both the resultant CoMFA and CoMSIA models exhibited satisfactory predictability (with Q(2) (cross-validated correlation coefficient) = 0.557, R(2)ncv (non-cross-validated correlation coefficient) = 0.740, R(2)pre (predicted correlation coefficient) = 0.749 and Q(2) = 0.598, R(2)ncv = 0.767, R(2)pre = 0.860, respectively). Good consistency was observed between the 3D-QSAR models and the pharmacophore model that the hydrophobic interaction and hydrogen bonds play crucial roles in the mechanism of actions. The corresponding contour maps generated by these models provide more diverse information about the key intermolecular interactions of inhibitors with the surrounding environment. All these models have extended the understanding of imidazole-based compounds in the structure-activity relationship, and are useful for rational design and screening of novel 2-thioimidazole-based TNF-α release inhibitors.
State-Space System Realization with Input- and Output-Data Correlation
NASA Technical Reports Server (NTRS)
Juang, Jer-Nan
1997-01-01
This paper introduces a general version of the information matrix consisting of the autocorrelation and cross-correlation matrices of the shifted input and output data. Based on the concept of data correlation, a new system realization algorithm is developed to create a model directly from input and output data. The algorithm starts by computing a special type of correlation matrix derived from the information matrix. The special correlation matrix provides information on the system-observability matrix and the state-vector correlation. A system model is then developed from the observability matrix in conjunction with other algebraic manipulations. This approach leads to several different algorithms for computing system matrices for use in representing the system model. The relationship of the new algorithms with other realization algorithms in the time and frequency domains is established with matrix factorization of the information matrix. Several examples are given to illustrate the validity and usefulness of these new algorithms.
The development and psychometric properties of the Turkish death anxiety scale (TDAS).
Sarıkaya, Yusuf; Baloğlu, Mustafa
2016-08-01
The purpose of the present study was to develop the Turkish Death Anxiety Scale (TDAS) and test its initial psychometric properties. Four independent samples participated in the study: 943 college students in item generation, 388 college students in validation, 171 college students in reliability investigation, and 338 adults in cross-validation. Principal component analysis with a varimax rotation revealed that 20 items of the scale contained three factors (i.e., Ambiguity of Death, Exposure to Death, and Agony of Death), which explained over 67% of the total variability. Confirmatory factor analyses indicated acceptable fit. Significant correlations were found between the scale and death anxiety, state anxiety, trait anxiety, depression, and hopelessness in the student sample. In the adult sample, death anxiety significantly correlated with trait anxiety. Reliability coefficients were also found acceptable. The authors conclude that the TDAS is a promising instrument in assessing the death anxiety levels in Turkey.
TWO MEASURES FOR CROSS-CULTURAL RESEARCH ON MORALITY: COMPARISON AND REVISION.
Zhang, Yanyan; Li, Sisi
2015-08-01
The current research assessed the reliability and validity of two Western measures of morality in a Chinese sample, namely the Community, Autonomy, and Divinity Scale (CADS) and the Moral Foundations Questionnaire (MFQ). Questionnaires were administered to 274 Chinese participants in Northern China (M age = 25.4 yr., SD = 8.50; 86% women). Confirmatory factor analysis using a structural equation model was conducted to evaluate the construct validity of the two scales. The results indicated a reasonable model fit of both the CADS and the MFQ after certain modifications. The revised versions of both measures had good internal consistency reliabilities. Correlation analysis indicated moderate correlations between the dimensions of the two scales. Regarding the content of morality, Chinese people endorsed more of the traditional ethics and foundations than people from Western cultures in other studies. In addition, participants who reported a religious affiliation scored higher on the Divinity subscale compared to those who claimed to be atheists.
NASA Astrophysics Data System (ADS)
Reimus, P. W.
2010-12-01
A process-oriented modeling approach is implemented to examine the importance of parameter variances, correlation lengths, and especially cross-correlations in contaminant transport predictions over large scales. It is shown that the most important consideration is the correlation between flow rates and retardation processes (e.g., sorption, matrix diffusion) in the system. If flow rates are negatively correlated with retardation factors in systems containing multiple flow pathways, then characterizing these negative correlation(s) may have more impact on reactive transport modeling than microscale information. Such negative correlations are expected in porous-media systems where permeability is negatively correlated with clay content and rock alteration (which are usually associated with increased sorption). Likewise, negative correlations are expected in fractured rocks where permeability is positively correlated with fracture apertures, which in turn are negatively correlated with sorption and matrix diffusion. Parameter variances and correlation lengths are also shown to have important effects on reactive transport predictions, but they are less important than parameter cross-correlations. Microscale information pertaining to contaminant transport has become more readily available as characterization methods and spectroscopic instrumentation have achieved lower detection limits, greater resolution, and better precision. Obtaining detailed mechanistic insights into contaminant-rock-water interactions is becoming a routine practice in characterizing reactive transport processes in groundwater systems (almost necessary for high-profile publications). Unfortunately, a quantitative link between microscale information and flow and transport parameter distributions or cross-correlations has not yet been established. One reason for this is that quantitative microscale information is difficult to obtain in complex, heterogeneous systems, so simple systems that lack the complexity and heterogeneity of real aquifer materials are often studied. Another is that instrumentation used to obtain microscale information often probes only one variable or family of variables at a time, so linkages to other variables must be inferred by indirect means from other lines of evidence. Despite these limitations, microscale information can be useful in the development and validation of reactive transport models. For example, knowledge of mineral phases that have strong affinities for contaminants can help in the development of cross-correlations between flow and sorption parameters via characterization of permeability and mineral distributions in aquifers. Likewise, microscale information on pore structures in low-permeability zones and contaminant penetration distances into these zones from higher-permeability zones (e.g., fractures) can provide valuable constraints on the representation of diffusive mass transfer processes between flowing porosity and secondary porosity. The prioritization of obtaining microscale information in any groundwater system can be informed by modeling exercises such as those conducted for this study.
Kanehara, Akiko; Kotake, Risa; Miyamoto, Yuki; Kumakura, Yousuke; Morita, Kentaro; Ishiura, Tomoko; Shimizu, Kimiko; Fujieda, Yumiko; Ando, Shuntaro; Kondo, Shinsuke; Kasai, Kiyoto
2017-11-07
Personal recovery is increasingly recognised as an important outcome measure in mental health services. This study aimed to develop a Japanese version of the Questionnaire about the Process of Recovery (QPR-J) and test its validity and reliability. The study comprised two stages that employed the cross-sectional and prospective cohort designs, respectively. We translated the questionnaire using a standard translation/back-translation method. Convergent validity was examined by calculating Pearson's correlation coefficients with scores on the Recovery Assessment Scale (RAS) and the Short-Form-8 Health Survey (SF-8). An exploratory factor analysis (EFA) was conducted to examine factorial validity. We used intraclass correlation and Cronbach's alpha to examine the test-retest and internal consistency reliability of the QPR-J's 22-item full scale, 17-item intrapersonal and 5-item interpersonal subscales. We conducted an EFA along with a confirmatory factor analysis (CFA). Data were obtained from 197 users of mental health services (mean age: 42.0 years; 61.9% female; 49.2% diagnosed with schizophrenia). The QPR-J showed adequate convergent validity, exhibiting significant, positive correlations with the RAS and SF-8 scores. The QPR-J's full version, subscales, showed excellent test-retest and internal consistency reliability, with the exception of acceptable but relatively low internal consistency reliability for the interpersonal subscale. Based on the results of the CFA and EFA, we adopted the factor structure extracted from the original 2-factor model based on the present CFA. The QPR-J is an adequately valid and reliable measure of the process of recovery among Japanese users with mental health services.
Development and validation of the neck dissection impairment index: a quality of life measure.
Taylor, Rodney J; Chepeha, Judith C; Teknos, Theodoros N; Bradford, Carol R; Sharma, Pramod K; Terrell, Jeffrey E; Hogikyan, Norman D; Wolf, Gregory T; Chepeha, Douglas B
2002-01-01
To validate a health-related quality-of-life (QOL) instrument for patients following neck dissection and to identify the factors that affect QOL following neck dissection. Cross-sectional validation study. The outpatient clinic of a tertiary care cancer center. Convenience sample of 54 patients previously treated for head and neck cancer who underwent a selective neck dissection or modified radical neck dissection (64 total neck dissections). Patients had a minimum postoperative convalescence of 11 months. Thirty-two underwent accessory nerve-sparing modified radical neck dissection, and 32 underwent selective neck dissection. A 10-item, self-report instrument, the Neck Dissection Impairment Index (NDII), was developed and validated. Reliability was evaluated with test-retest correlation and internal consistency using the Cronbach alpha coefficient. Convergent validity was assessed using the 36-Item Short-Form Health Survey (SF-36) and the Constant Shoulder Scale, a shoulder function test. Multiple variable regression was used to determine variables that most affected QOL following neck dissection The 10-item NDII test-retest correlation was 0.91 (P<.001) with an internal consistency Cronbach alpha coefficient of.95. The NDII correlated with the Constant Shoulder Scale (r = 0.85, P<.001) and with the SF-36 physical functioning (r = 0.50, P<.001) and role-physical functioning (r = 0.60, P<.001) domains. Using multiple variable regression, the variables that contributed most to QOL score were patient's age and weight, radiation treatment, and neck dissection type. The NDII is a valid, reliable instrument for assessing neck dissection impairment. Patient's age, weight, radiation treatment, and neck dissection type were important factors that affect QOL following neck dissection.
Transcultural adaptation and validation of a satisfaction with life scale for Chilean adolescents.
Álvarez, Carola A; Briceño, Ana M; Álvarez, Karla; Abufhele, Marcela; Delgado, Iris
2018-02-01
In recent years, there has been an increasing interest in the determinants of subjecti ve well-being and happiness. In that context, life satisfaction is one of the measures used to assess subjective well-being, with emphasis in adult population. Adapt and validate (cultu rally and linguistically) the Canadian "Satisfaction with Life adapted for Children" (SWLS-C) in Chilean adolescents, in order to assess their global judgement about their own lives. Cross-sectional study, with adolescents between 10 to 18 years old, of both sexes and three socioeconomic levels in the Metropolitan region of Chile. After a process of translation and back translation, the scale SWLS-C was applied in 3 groups: cognitive interviews (n = 23) to evaluate se mantics, content, reliability and construct validity, a second group was used as pretest (n = 24) and a third for the validation of the test (n = 200). Factor analysis was performed and measurement of convergent and divergent validity. The internal consistency of the scale through Cronbach's alpha was 0.815, with item-total correlations between 0.51 and 0.7. The correlation between scale items varies between 0.390 and 0.607. In the main component analysis, all items met the require ment of a factor greater than 0.3. The inverse correlation between SWLS-C and CDI was significant, with a linear R2 of 0.465. The Chilean version of the SWLS-C shows adequate psycho metric properties, construct validity, confirming its unidimensional character and the need to keep each item of the Canadian version. SWLS-C, in its Chilean version, is suitable to be self-applied in adolescent population. Further studies are needed to provide further evidence.
Carvalho, Flávia A; Morelhão, Priscila K; Franco, Marcia R; Maher, Chris G; Smeets, Rob J E M; Oliveira, Crystian B; Freitas Júnior, Ismael F; Pinto, Rafael Z
2017-02-01
Although there is some evidence for reliability and validity of self-report physical activity (PA) questionnaires in the general adult population, it is unclear whether we can assume similar measurement properties in people with chronic low back pain (LBP). To determine the test-retest reliability of the International Physical Activity Questionnaire (IPAQ) long-version and the Baecke Physical Activity Questionnaire (BPAQ) and their criterion-related validity against data derived from accelerometers in patients with chronic LBP. Cross-sectional study. Patients with non-specific chronic LBP were recruited. Each participant attended the clinic twice (one week interval) and completed self-report PA. Accelerometer measures >7 days included time spent in moderate-and-vigorous physical activity, steps/day, counts/minute, and vector magnitude counts/minute. Intraclass Correlation Coefficients (ICC) and Bland and Altman method were used to determine reliability and spearman rho correlation were used for criterion-related validity. A total of 73 patients were included in our analyses. The reliability analyses revealed that the BPAQ and its subscales have moderate to excellent reliability (ICC 2,1 : 0.61 to 0.81), whereas IPAQ and most IPAQ domains (except walking) showed poor reliability (ICC 2,1 : 0.20 to 0.40). The Bland and Altman method revealed larger discrepancies for the IPAQ. For the validity analysis, questionnaire and accelerometer measures showed at best fair correlation (rho < 0.37). Although the BPAQ showed better reliability than the IPAQ long-version, both questionnaires did not demonstrate acceptable validity against accelerometer data. These findings suggest that questionnaire and accelerometer PA measures should not be used interchangeably in this population. Copyright © 2016 Elsevier Ltd. All rights reserved.
Facial disability index (FDI): Adaptation to Spanish, reliability and validity
Gonzalez-Cardero, Eduardo; Cayuela, Aurelio; Acosta-Feria, Manuel; Gutierrez-Perez, Jose-Luis
2012-01-01
Objectives: To adapt to Spanish the facial disability index (FDI) described by VanSwearingen and Brach in 1995 and to assess its reliability and validity in patients with facial nerve paresis after parotidectomy. Study Design: The present study was conducted in two different stages: a) cross-cultural adaptation of the questionnaire and b) cross-sectional study of a control group of 79 Spanish-speaking patients who suffered facial paresis after superficial parotidectomy with facial nerve preservation. The cross-cultural adaptation process comprised the following stages: (I) initial translation, (II) synthesis of the translated document, (III) retro-translation, (IV) review by a board of experts, (V) pilot study of the pre-final draft and (VI) analysis of the pilot study and final draft. Results: The reliability and internal consistency of every one of the rating scales included in the FDI (Cronbach’s alpha coefficient) was 0.83 for the complete scale and 0.77 and 0.82 for the physical and the social well-being subscales. The analysis of the factorial validity of the main components of the adapted FDI yielded similar results to the original questionnaire. Bivariate correlations between FDI and House-Brackmann scale were positive. The variance percentage was calculated for all FDI components. Conclusions: The FDI questionnaire is a specific instrument for assessing facial neuromuscular dysfunction which becomes a useful tool in order to determine quality of life in patients with facial nerve paralysis. Spanish adapted FDI is equivalent to the original questionnaire and shows similar reliability and validity. The proven reproducibi-lity, reliability and validity of this questionnaire make it a useful additional tool for evaluating the impact of facial nerve paralysis in Spanish-speaking patients. Key words:Parotidectomy, facial nerve paralysis, facial disability. PMID:22926474
On the validation of seismic imaging methods: Finite frequency or ray theory?
Maceira, Monica; Larmat, Carene; Porritt, Robert W.; ...
2015-01-23
We investigate the merits of the more recently developed finite-frequency approach to tomography against the more traditional and approximate ray theoretical approach for state of the art seismic models developed for western North America. To this end, we employ the spectral element method to assess the agreement between observations on real data and measurements made on synthetic seismograms predicted by the models under consideration. We check for phase delay agreement as well as waveform cross-correlation values. Based on statistical analyses on S wave phase delay measurements, finite frequency shows an improvement over ray theory. Random sampling using cross-correlation values identifiesmore » regions where synthetic seismograms computed with ray theory and finite-frequency models differ the most. Our study suggests that finite-frequency approaches to seismic imaging exhibit measurable improvement for pronounced low-velocity anomalies such as mantle plumes.« less
Bilenko, Natalia Y; Gallant, Jack L
2016-01-01
In this article we introduce Pyrcca, an open-source Python package for performing canonical correlation analysis (CCA). CCA is a multivariate analysis method for identifying relationships between sets of variables. Pyrcca supports CCA with or without regularization, and with or without linear, polynomial, or Gaussian kernelization. We first use an abstract example to describe Pyrcca functionality. We then demonstrate how Pyrcca can be used to analyze neuroimaging data. Specifically, we use Pyrcca to implement cross-subject comparison in a natural movie functional magnetic resonance imaging (fMRI) experiment by finding a data-driven set of functional response patterns that are similar across individuals. We validate this cross-subject comparison method in Pyrcca by predicting responses to novel natural movies across subjects. Finally, we show how Pyrcca can reveal retinotopic organization in brain responses to natural movies without the need for an explicit model.
Bilenko, Natalia Y.; Gallant, Jack L.
2016-01-01
In this article we introduce Pyrcca, an open-source Python package for performing canonical correlation analysis (CCA). CCA is a multivariate analysis method for identifying relationships between sets of variables. Pyrcca supports CCA with or without regularization, and with or without linear, polynomial, or Gaussian kernelization. We first use an abstract example to describe Pyrcca functionality. We then demonstrate how Pyrcca can be used to analyze neuroimaging data. Specifically, we use Pyrcca to implement cross-subject comparison in a natural movie functional magnetic resonance imaging (fMRI) experiment by finding a data-driven set of functional response patterns that are similar across individuals. We validate this cross-subject comparison method in Pyrcca by predicting responses to novel natural movies across subjects. Finally, we show how Pyrcca can reveal retinotopic organization in brain responses to natural movies without the need for an explicit model. PMID:27920675
Cross-cultural adaptation of the German version of the spinal stenosis measure.
Wertli, Maria M; Steurer, Johann; Wildi, Lukas M; Held, Ulrike
2014-06-01
To validate the German version of the spinal stenosis measure (SSM), a disease-specific questionnaire assessing symptom severity, physical function, and satisfaction with treatment in patients with lumbar spinal stenosis. After translation, cross-cultural adaptation, and pilot testing, we assessed internal consistency, test-retest reliability, construct validity, and responsiveness of the SSM subscales. Data from a large Swiss multi-center prospective cohort study were used. Reference scales for the assessment of construct validity and responsiveness were the numeric rating scale, pain thermometer, and the Roland Morris Disability Questionnaire. One hundred and eight consecutive patients were included in this validation study, recruited from five different centers. Cronbach's alpha was above 0.8 for all three subscales of the SSM. The objectivity of the SSM was assessed using a partial credit approach. The model showed a good global fit to the data. Of the 108 patients 78 participated in the test-retest procedure. The ICC values were above 0.8 for all three subscales of the SSM. Correlations with reference scales were above 0.7 for the symptom and function subscales. For satisfaction subscale, it was 0.66 or above. Clinically meaningful changes of the reference scales over time were associated with significantly more improvement in all three SSM subscales (p < 0.001). Conclusion: The proposed version of the SSM showed very good measurement properties and can be considered validated for use in the German language.
Jalenques, I; Auclair, C; Roblin, J; Morand, D; Tourtauchaux, R; May, R; Vaille-Perret, E; Watts, J; Gerbaud, L; De Leo, D
2013-04-01
To cross-culturally adapt a French version of the LEIPAD, a self-administered questionnaire assessing the health-related quality of life (HRQoL) in adults aged 65 years and over living at home, and to evaluate its psychometric properties. After having translated LEIPAD in accordance with guidelines, we studied psychometric properties: reliability and construct validity-factor analysis, relationships between items and scales, internal consistency, concurrent validity with the Medical Outcome Study Short-Form 36 and known-groups validity. The results obtained in a sample of 195 elderly from the general population showed very good acceptability, with response rates superior to 93 %. Exploratory factor analysis extracted eight factors providing a multidimensionality structure with five misclassifications of items in the seven theoretical scales. Good internal consistency (Cronbach's alpha ranging from 0.73 and 0.86) and strong test-retest reliability (ICCs higher than 0.80 for six scales and 0.70 for one) were demonstrated. Concurrent validity with the SF-36 showed small to strong expected correlations. This first evaluation of the French version of LEIPAD's psychometric properties provides evidence in construct validity and reliability. It would allow HRQoL assessment in clinical and common practice, and investigators would be able to take part in national and international research projects.
Rogers, Richard; Gillard, Nathan D; Wooley, Chelsea N; Kelsey, Katherine R
2013-02-01
A major strength of the Personality Assessment Inventory (PAI) is its systematic assessment of response styles, including feigned mental disorders. Recently, Mogge, Lepage, Bell, and Ragatz developed and provided the initial validation for the Negative Distortion Scale (NDS). Using rare symptoms as its detection strategy for feigning, the usefulness of NDS was examined via a known-groups comparison. The current study sought to cross-validate the NDS by implementing a between-subjects simulation design. Simulators were asked to feign total disability in an effort to secure unwarranted compensation from their insurance company. Even in an inpatient sample with severe Axis I disorders and concomitant impairment, the NDS proved effective as a rare-symptom strategy with low levels of item endorsement that remained mostly stable across genders. For construct validity, the NDS was moderately correlated with the Structured Interview of Reported Symptoms-Second Edition and other PAI feigning scales. For discriminant validity, it yielded a very large effect size (d = 1.81), surpassing the standard PAI feigning indicators. Utility estimates appeared to be promising for both ruling-out (low probability of feigning) and ruling-in (high probability of feigning) determinations at different base rates. Like earlier research, the data supported the creation of well-defined groups with indeterminate scores (i.e., the cut score ± 1 SEM) removed to avoid high rates of misclassifications for this narrow band.
Rational selection of training and test sets for the development of validated QSAR models
NASA Astrophysics Data System (ADS)
Golbraikh, Alexander; Shen, Min; Xiao, Zhiyan; Xiao, Yun-De; Lee, Kuo-Hsiung; Tropsha, Alexander
2003-02-01
Quantitative Structure-Activity Relationship (QSAR) models are used increasingly to screen chemical databases and/or virtual chemical libraries for potentially bioactive molecules. These developments emphasize the importance of rigorous model validation to ensure that the models have acceptable predictive power. Using k nearest neighbors ( kNN) variable selection QSAR method for the analysis of several datasets, we have demonstrated recently that the widely accepted leave-one-out (LOO) cross-validated R2 (q2) is an inadequate characteristic to assess the predictive ability of the models [Golbraikh, A., Tropsha, A. Beware of q2! J. Mol. Graphics Mod. 20, 269-276, (2002)]. Herein, we provide additional evidence that there exists no correlation between the values of q 2 for the training set and accuracy of prediction ( R 2) for the test set and argue that this observation is a general property of any QSAR model developed with LOO cross-validation. We suggest that external validation using rationally selected training and test sets provides a means to establish a reliable QSAR model. We propose several approaches to the division of experimental datasets into training and test sets and apply them in QSAR studies of 48 functionalized amino acid anticonvulsants and a series of 157 epipodophyllotoxin derivatives with antitumor activity. We formulate a set of general criteria for the evaluation of predictive power of QSAR models.
A validation study of public health knowledge, skills, social responsibility and applied learning.
Vackova, Dana; Chen, Coco K; Lui, Juliana N M; Johnston, Janice M
2018-06-22
To design and validate a questionnaire to measure medical students' Public Health (PH) knowledge, skills, social responsibility and applied learning as indicated in the four domains recommended by the Association of Schools & Programmes of Public Health (ASPPH). A cross-sectional study was conducted to develop an evaluation tool for PH undergraduate education through item generation, reduction, refinement and validation. The 74 preliminary items derived from the existing literature were reduced to 55 items based on expert panel review which included those with expertise in PH, psychometrics and medical education, as well as medical students. Psychometric properties of the preliminary questionnaire were assessed as follows: frequency of endorsement for item variance; principal component analysis (PCA) with varimax rotation for item reduction and factor estimation; Cronbach's Alpha, item-total correlation and test-retest validity for internal consistency and reliability. PCA yielded five factors: PH Learning Experience (6 items); PH Risk Assessment and Communication (5 items); Future Use of Evidence in Practice (6 items); Recognition of PH as a Scientific Discipline (4 items); and PH Skills Development (3 items), explaining 72.05% variance. Internal consistency and reliability tests were satisfactory (Cronbach's Alpha ranged from 0.87 to 0.90; item-total correlation > 0.59). Lower paired test-retest correlations reflected instability in a social science environment. An evaluation tool for community-centred PH education has been developed and validated. The tool measures PH knowledge, skills, social responsibilities and applied learning as recommended by the internationally recognised Association of Schools & Programmes of Public Health (ASPPH).
Cross-cultural application of the Korean version of Ureteral Stent Symptoms Questionnaire.
Park, Jinsung; Shin, Dong Wook; You, Changhee; Chung, Kyung Jin; Han, Deok Hyun; Joshi, Hrishi B; Park, Hyung Keun
2012-11-01
We validated the Korean version of the Ureteral Stent Symptoms Questionnaire (USSQ) in patients with an indwelling ureteral stent. Linguistic validation of the original USSQ was performed through a standard process including translation, back translation, and pilot study. A total of 65 patients who underwent ureteroscopic surgery were asked to complete the Korean USSQ as well as EuroQOL (male and female), the International Prostate Symptom Score (male), and Urogenital Distress Inventory-6 (female). Patients were evaluated at weeks 1 and 2 after stent placement and at week 4 after removal. Sixty-four healthy subjects without a ureteral stent were also asked to complete the Korean USSQ once. The psychometric properties of the questionnaire were analyzed. Internal consistencies (Cronbach α coefficients: 0.73-0.83) and test-retest reliability (Spearman correlation coefficient: ≥0.6) were satisfactory for urinary symptom, body pain, general health, and work performance domains. Most USSQ domains showed moderate correlations with each other. Convergent validity determined by correlation between other instruments and corresponding USSQ domain was satisfactory. Sensitivity to change and discriminant validity were also good in most domains (P<0.01). Only a small proportion of the study population had an active sexual life, with the stent in situ, limiting its analysis. The Korean version of the USSQ is a reliable and valid instrument that can be self-administered by Korean patients with a ureteral stent in the clinical and research settings. Further clinical studies in the Korean settings would be useful to provide robust data on sensitivity to change.
Psychometrics of chronic liver disease questionnaire in Chinese chronic hepatitis B patients
Zhou, Kai-Na; Zhang, Min; Wu, Qian; Ji, Zhen-Hao; Zhang, Xiao-Mei; Zhuang, Gui-Hua
2013-01-01
AIM: To evaluate psychometrics of the Chinese (mainland) chronic liver disease questionnaire (CLDQ) in patients with chronic hepatitis B (CHB). METHODS: A cross-sectional sample of 460 Chinese patients with CHB was selected from the Outpatient Department of the Eighth Hospital of Xi’an, including CHB (CHB without cirrhosis) (n = 323) and CHB-related cirrhosis (n = 137). The psychometrics includes reliability, validity and sensitivity. Internal consistency reliability was measured using Cronbach’s α. Convergent and discriminant validity was evaluated by item-scale correlation. Factorial validity was explored by principal component analysis with varimax rotation. Sensitivity was assessed using Cohen’s effect size (ES), and independent sample t test between CHB and CHB-related cirrhosis groups and between alanine aminotransferase (ALT) normal and abnormal groups after stratifying the disease (CHB and CHB-related cirrhosis). RESULTS: Internal consistency reliability of the CLDQ was 0.83 (range: 0.65-0.90). Most of the hypothesized item-scale correlations were 0.40 or over, and all of such hypothesized correlations were higher than the alternative ones, indicating satisfactory convergent and discriminant validity. Six factors were extracted after varimax rotation from the 29 items of CLDQ. The eligible Cohen’s ES with statistically significant independent sample t test was found in the overall CLDQ and abdominal, systematic, activity scales (CHB vs CHB-related cirrhosis), and in the overall CLDQ and abdominal scale in the stratification of patients with CHB (ALT normal vs abnormal). CONCLUSION: The CLDQ has acceptable reliability, validity and sensitivity in Chinese (mainland) patients with CHB. PMID:23801844
Schmidt, Simone; Hafner, Patricia; Klein, Andrea; Rubino-Nacht, Daniela; Gocheva, Vanya; Schroeder, Jonas; Naduvilekoot Devasia, Arjith; Zuesli, Stephanie; Bernert, Guenther; Laugel, Vincent; Bloetzer, Clemens; Steinlin, Maja; Capone, Andrea; Gloor, Monika; Tobler, Patrick; Haas, Tanja; Bieri, Oliver; Zumbrunn, Thomas; Fischer, Dirk; Bonati, Ulrike
2018-01-01
The development of new therapeutic agents for the treatment of Duchenne muscular dystrophy has put a focus on defining outcome measures most sensitive to capture treatment effects. This cross-sectional analysis investigates the relation between validated clinical assessments such as the 6-minute walk test, motor function measure and quantitative muscle MRI of thigh muscles in ambulant Duchenne muscular dystrophy patients, aged 6.5 to 10.8 years (mean 8.2, SD 1.1). Quantitative muscle MRI included the mean fat fraction using a 2-point Dixon technique, and transverse relaxation time (T2) measurements. All clinical assessments were highly significantly inter-correlated with p < 0.001. The strongest correlation with the motor function measure and its D1-subscore was shown by the 6-minute walk test. Clinical assessments showed no correlation with age. Importantly, quantitative muscle MRI values significantly correlated with all clinical assessments with the extensors showing the strongest correlation. In contrast to the clinical assessments, quantitative muscle MRI values were highly significantly correlated with age. In conclusion, the motor function measure and timed function tests measure disease severity in a highly comparable fashion and all tests correlated with quantitative muscle MRI values quantifying fatty muscle degeneration. Copyright © 2017 Elsevier B.V. All rights reserved.
Brazilian version of the body dysmorphic disorder examination.
Jorge, Renata Trajano Borges; Sabino Neto, Miguel; Natour, Jamil; Veiga, Daniela Francescato; Jones, Anamaria; Ferreira, Lydia Masako
2008-03-06
Body image improvement is considered to be the main reason for undergoing plastic surgery. The objective was to translate the Body Dysmorphic Disorder Examination (BDDE) into Brazilian Portuguese and to adapt and validate this questionnaire for use in Brazil. Cross-sectional survey, at the Department of Plastic Surgery of Universidade Federal de São Paulo. The BDDE was first translated into Portuguese and then back-translated into English. These translations were then discussed by healthcare professionals in order to establish the final Brazilian version. In a second stage, the validity and reliability of the BDDE were assessed. For this, patients were initially interviewed by two interviewers and subsequently, by only one of these interviewers. On the first occasion, in addition to the BDDE, the body shape questionnaire (BSQ) and the Rosenberg self-esteem scale were also applied. These questionnaires were applied to 90 patients. Six questions were modified during the assessment of cultural equivalence. Cronbach's alpha was 0.89 and the intraclass correlation coefficients for interobserver and test-retest reliability were 0.91 and 0.87, respectively. Pearson's coefficient showed no correlation between the BDDE and the Rosenberg self-esteem scale (0.22), whereas there was a moderate correlation between the BDDE and the BSQ (0.64). The BDDE was successfully translated and adapted, with good internal consistency, reliability and construct validity.
Sexual Orientation Self-Concept Ambiguity: Scale Adaptation and Validation.
Talley, Amelia E; Stevens, Jordan E
2017-07-01
The current article describes the adaptation of a measure of sexual orientation self-concept ambiguity (SSA) from an existing measure of general self-concept clarity. Latent "trait" scores of SSA reflect the extent to which a person's beliefs about their own sexual orientation are perceived as inconsistent, unreliable, or incongruent. Sexual minority and heterosexual women ( n = 348), ages 18 to 30, completed a cross-sectional survey. Categorical confirmatory factor analysis guided the selection of items to form a 10-item, self-report measure of SSA. In the current report, we also examine (a) reliability of the 10-item scale score, (b) measurement invariance based on respondents' sexual identity status and age group, and (c) correlations with preexisting surveys that purport to measure similar constructs and theoretical correlates. Evidence for internal reliability, measurement invariance (based on respondent sex), and convergent validity was also investigated in an independent, validation sample. The lowest SSA scores were reported by women who self-ascribed an exclusively heterosexual or exclusively lesbian/gay sexual identity, whereas those who reported a bisexual, mostly lesbian/gay, or mostly heterosexual identity, reported relatively higher SSA scores.
Park, Hyeon Jin; Yang, Hyung Kook; Shin, Dong Wook; Kim, Yoon Yi; Kim, Young Ae; Yun, Young Ho; Nam, Byung Ho; Bhatia, Smita; Park, Byung Kiu; Ghim, Thad T; Kang, Hyoung Jin; Park, Kyung Duk; Shin, Hee Young; Ahn, Hyo Seop
2013-12-01
We verified the reliability and validity of the Korean version of the Minneapolis-Manchester Quality of Life Instrument-Adolescent Form (KMMQL-AF) among Korean childhood cancer survivors. A total of 107 childhood cancer patients undergoing cancer treatment and 98 childhood cancer survivors who completed cancer treatment were recruited. To assess the internal structure of the KMMQL-AF, we performed multi-trait scaling analyses and exploratory factor analysis. Additionally, we compared each domains of the KMMQL-AF with those of the Karnofsky Performance Status Scale and the Revised Children's Manifest Anxiety Scale (RCMAS). Internal consistency of the KMMQL-AF was sufficient (Cronbach's alpha: 0.78-0.92). In multi-trait scaling analyses, the KMMQL-AF showed sufficient construct validity. The "physical functioning" domain showed moderate correlation with Karnofsky scores and the "psychological functioning" domain showed moderate-to-high correlation with the RCMAS. The KMMQL-AF discriminated between subgroups of different adolescent cancer survivors depending on treatment completion. The KMMQL-AF is a sufficiently reliable and valid instrument for measuring quality of life among Korean childhood cancer survivors.
Cross-cultural adaptation and validation to Brazil of the Obesity-related Problems Scale
Brasil, Andreia Mara Brolezzi; Brasil, Fábio; Maurício, Angélica Aparecida; Vilela, Regina Maria
2017-01-01
ABSTRACT Objective To validate a reliable version of the Obesity-related Problems Scale in Portuguese to use it in Brazil. Methods The Obesity-related Problems Scale was translated and transculturally adapted. Later it was simultaneously self-applied with a 12-item version of the World Health Organization Disability Assessment Schedule 2.0 (WHODAS 2.0), to 50 obese patients and 50 non-obese individuals, and applied again to half of them after 14 days. Results The Obesity-related Problems scale was able to differentiate obese from non-obese individuals with higher accuracy than WHODAS 2.0, correlating with this scale and with body mass index. The factor analysis determined a two-dimensional structure, which was confirmed with χ2/df=1.81, SRMR=0.05, and CFI=0.97. The general a coefficient was 0.90 and the inter-item intra-class correlation, in the reapplication, ranged from 0.75 to 0.87. Conclusion The scale proved to be valid and reliable for use in the Brazilian population, without the need to exclude items. PMID:29091155
Naghdi, Soofia; Nakhostin Ansari, Noureddin; Farhadi, Yasaman; Ebadi, Safoora; Entezary, Ebrahim; Glazer, Douglas
2016-10-01
The aim of the present study was to develop and provide validation statistics for the Persian Injury-Psychological Readiness to Return to Sport scale (I-PRRS) following a cross-sectional and prospective cohort study design. The I-PRRS was forward/back-translated and culturally adapted into Persian language. The Persian I-PRRS was administered to 100 injured athletes (93 male; age 26.0 ± 5.6 years; time since injury 4.84 ± 6.4 months) and 50 healthy athletes (36 male; mean age 25.7 ± 6.0 years). The Persian I-PRRS was re-administered to 50 injured athletes at 1 week to examine test-retest reliability. There were no floor or ceiling effects confirming the content validity of Persian I-PRRS. The internal consistency reliability was good. Excellent test-retest reliability and agreement were demonstrated. The statistically significant difference in Persian I-PRRS total scores between the injured athletes and healthy athletes provides an evidence of discriminative validity. The Persian I-PRRS total scores were positively correlated with the Farsi Mood Scale (FARMS) total scores, showing construct validity. The principal component analysis indicated a two-factor solution consisting of "Confidence to play" and "Confidence in the injured body part and skill level". The Persian I-PRRS showed excellent reliability and validity and can be used to assess injured athletes' psychological readiness to return to sport among Persian-speaking populations.
The use of the FACT-H&N (v4) in clinical settings within a developing country: a mixed method study.
Bilal, Sobia; Doss, Jennifer Geraldine; Rogers, Simon N
2014-12-01
In the last decade there has been an increasing awareness about 'quality of life' (QOL) of cancer survivors in developing countries. The study aimed to cross-culturally adapt and validate the FACT-H&N (v4) in Urdu language for Pakistani head and neck cancer patients. In this study the 'same language adaptation method' was used. Cognitive debriefing through in-depth interviews of 25 patients to assess semantic, operational and conceptual equivalence was done. The validation phase included 50 patients to evaluate the psychometric properties. The translated FACT-H&N was easily comprehended (100%). Cronbach's alpha for FACT-G subscales ranged from 0.726 - 0.969. The head and neck subscale and Pakistani questions subscale showed low internal consistency (0.426 and 0.541 respectively). Instrument demonstrated known-group validity in differentiating patients of different clinical stages, treatment status and tumor sites (p < 0.05). Most FACT summary scales correlated strongly with each other (r > 0.75) and showed convergent validity (r > 0.90), with little discriminant validity. Factor analysis revealed 6 factors explaining 85.1% of the total variance with very good (>0.8) Kaiser-Meyer-Olkin and highly significant Bartlett's Test of Sphericity (p < 0.001). The cross-culturally adapted FACT-H&N into Urdu language showed adequate reliability and validity to be incorporated in Pakistani clinical settings for head and neck cancer patients. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Bernardo, R
1996-11-01
Best linear unbiased prediction (BLUP) has been found to be useful in maize (Zea mays L.) breeding. The advantage of including both testcross additive and dominance effects (Intralocus Model) in BLUP, rather than only testcross additive effects (Additive Model), has not been clearly demonstrated. The objective of this study was to compare the usefulness of Intralocus and Additive Models for BLUP of maize single-cross performance. Multilocation data from 1990 to 1995 were obtained from the hybrid testing program of Limagrain Genetics. Grain yield, moisture, stalk lodging, and root lodging of untested single crosses were predicted from (1) the performance of tested single crosses and (2) known genetic relationships among the parental inbreds. Correlations between predicted and observed performance were obtained with a delete-one cross-validation procedure. For the Intralocus Model, the correlations ranged from 0.50 to 0.66 for yield, 0.88 to 0.94 for moisture, 0.47 to 0.69 for stalk lodging, and 0.31 to 0.45 for root lodging. The BLUP procedure was consistently more effective with the Intralocus Model than with the Additive Model. When the Additive Model was used instead of the Intralocus Model, the reductions in the correlation were largest for root lodging (0.06-0.35), smallest for moisture (0.00-0.02), and intermediate for yield (0.02-0.06) and stalk lodging (0.02-0.08). The ratio of dominance variance (v D) to total genetic variance (v G) was highest for root lodging (0.47) and lowest for moisture (0.10). The Additive Model may be used if prior information indicates that VD for a given trait has little contribution to VG. Otherwise, the continued use of the Intralocus Model for BLUP of single-cross performance is recommended.
Giovannelli, Jonathan; Dallongeville, Jean; Wagner, Aline; Bongard, Vanina; Laillet, Brigitte; Marecaux, Nadine; Ruidavets, Jean Bernard; Haas, Bernadette; Ferrieres, Jean; Arveiler, Dominique; Simon, Chantal; Dauchet, Luc
2014-04-01
Food frequency questionnaires (FFQs) are often used to evaluate individuals' food intakes in epidemiologic studies because of their simplicity and low cost. To assess the validity of a short (24 items), qualitative FFQ used in the MONA LISA-NUT study. Cross-sectional study of a representative sample in three French counties. The sample included 2,630 participants aged 35 to 65 years from the MONA LISA-NUT study. Food consumption was measured with the FFQ and via food records for 3 consecutive days. Plasma fatty acids were measured from a subset of participants. The FFQ items' validity was assessed by calculating crude and deattenuated Pearson correlation coefficients between frequencies reported by the FFQ and average weights reported by the food records. Furthermore, the validity of some items of the FFQ measuring the consumption of fatty foods was assessed by calculating Pearson correlation coefficients between frequencies of consumption of these foods and dosages of the corresponding plasma fatty acids: fish and eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), olive oil and oleic acid, margarine and elaidic acid, and dairy products and pentadecanoic and heptadecanoic acids. The mean of the deattenuated Pearson correlation coefficients for all items was 0.46, with values ranging from 0.22 (fried food) to 0.77 (breakfast cereal). The correlation coefficient was ≤ 0.4 for one third of the 24 items. Moderate correlations were found between fish and EPA/DHA (EPA: r=0.43, 95% CI 0.33 to 0.51; DHA: r=0.39, 95% CI 0.30 to 0.47), but not for other food items. One third of the 24 items in the short, qualitative FFQ evaluated here were not sufficiently valid. However, for the food groups most commonly studied in the literature, this FFQ had the same degree of validity as other questionnaires designed to classify subjects according to their level of intake. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
Christensen, Sara E; Möller, Elisabeth; Bonn, Stephanie E; Ploner, Alexander; Bälter, Olle; Lissner, Lauren; Bälter, Katarina
2014-02-21
The meal- and Web-based food frequency questionnaires, Meal-Q and MiniMeal-Q, were developed for cost-efficient assessment of dietary intake in epidemiological studies. The objective of this study was to evaluate the relative validity of micronutrient and fiber intake assessed with Meal-Q and MiniMeal-Q. The reproducibility of Meal-Q was also evaluated. A total of 163 volunteer men and women aged between 20 and 63 years were recruited from Stockholm County, Sweden. Assessment of micronutrient and fiber intake with the 174-item Meal-Q was compared to a Web-based 7-day weighed food record (WFR). Two administered Meal-Q questionnaires were compared for reproducibility. The 126-item MiniMeal-Q, developed after the validation study, was evaluated in a simulated validation by using truncated Meal-Q data. The study population consisted of approximately 80% women (129/163) with a mean age of 33 years (SD 12) who were highly educated (130/163, 80% with >12 years of education) on average. Cross-classification of quartiles with the WFR placed 69% to 90% in the same/adjacent quartile for Meal-Q and 67% to 89% for MiniMeal-Q. Bland-Altman plots with the WFR and the questionnaires showed large variances and a trend of increasing underestimation with increasing intakes. Deattenuated and energy-adjusted Spearman rank correlations between the questionnaires and the WFR were in the range ρ=.25-.69, excluding sodium that was not statistically significant. Cross-classifications of quartiles of the 2 Meal-Q administrations placed 86% to 97% in the same/adjacent quartile. Intraclass correlation coefficients for energy-adjusted intakes were in the range of .50-.76. With the exception of sodium, this validation study demonstrates Meal-Q and MiniMeal-Q to be useful methods for ranking micronutrient and fiber intake in epidemiological studies with Web-based data collection.
Kersten, Paula; Vandal, Alain C; Elder, Hinemoa; McPherson, Kathryn M
2018-04-21
This observational study examines the internal construct validity, internal consistency and cross-informant reliability of the Strengths and Difficulties Questionnaire (SDQ) in a New Zealand preschool population across four ethnicity strata (New Zealand European, Māori, Pasifika, Asian). Rasch analysis was employed to examine internal validity on a subsample of 1000 children. Internal consistency (n=29 075) and cross-informant reliability (n=17 006) were examined using correlations, intraclass correlation coefficients and Cronbach's alpha on the sample available for such analyses. Data were used from a national SDQ database provided by the funder, pertaining to New Zealand domiciled children aged 4 and 5 and scored by their parents and teachers. The five subscales do not fit the Rasch model (as indicated by the overall fit statistics), contain items that are biased (differential item functioning (DIF)) by key variables, suffer from a floor and ceiling effect and have unacceptable internal consistency. After dealing with DIF, the Total Difficulty scale does fit the Rasch model and has good internal consistency. Parent/teacher inter-rater reliability was unacceptably low for all subscales. The five SDQ subscales are not valid and not suitable for use in their own right in New Zealand. We have provided a conversion table for the Total Difficulty scale, which takes account of bias by ethnic group. Clinicians should use this conversion table in order to reconcile DIF by culture in final scores. It is advisable to use both parents and teachers' feedback when considering children's needs for referral of further assessment. Future work should examine whether validity is impacted by different language versions used in the same country. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Validation of a self-administered web-based 24-hour dietary recall among pregnant women.
Savard, Claudia; Lemieux, Simone; Lafrenière, Jacynthe; Laramée, Catherine; Robitaille, Julie; Morisset, Anne-Sophie
2018-04-23
The use of valid dietary assessment methods is crucial to analyse adherence to dietary recommendations among pregnant women. This study aims to assess the relative validity of a self-administered Web-based 24-h dietary recall, the R24W, against a pen-paper 3-day food record (FR) among pregnant women. Sixty (60) pregnant women recruited at 9.3 ± 0.7 weeks of pregnancy in Quebec City completed, at each trimester, 3 R24W and a 3-day FR. Mean energy and nutrient intakes reported by both tools were compared using paired Student T-Tests. Pearson correlations were used to analyze the association between both methods. Agreement between the two methods was evaluated using cross-classification analyses, weighted kappa coefficients and Bland-Altman analyses. Pearson correlation coefficients were all significant, except for vitamin B 12 (r = 0.03; p = 0.83) and ranged from 0.27 to 0.76 (p < 0.05). Differences between mean intakes assessed by the R24W and the FR did not exceed 10% in 19 variables and were not significant for 16 out of 26 variables. In cross-classification analyses, the R24W ranked, on average, 79.1% of participants in the same or adjacent quartiles as the FR. Compared to a 3-day FR, the R24W is a valid method to assess intakes of energy and most nutrients but may be less accurate in the evaluation of intakes of fat (as a proportion of energy intake), vitamin D, zinc and folic acid. During pregnancy, the R24W was a more accurate tool at a group-level than at an individual-level and should, therefore, be used in an epidemiological rather than a clinical setting. The R24W may be particularly valuable as a tool used in cohort studies to provide valid information on pregnant women's dietary intakes and facilitate evaluation of associations between diet and adverse pregnancy outcomes.
Bruno, Alexander G.; Bouxsein, Mary L.; Anderson, Dennis E.
2015-01-01
We developed and validated a fully articulated model of the thoracolumbar spine in opensim that includes the individual vertebrae, ribs, and sternum. To ensure trunk muscles in the model accurately represent muscles in vivo, we used a novel approach to adjust muscle cross-sectional area (CSA) and position using computed tomography (CT) scans of the trunk sampled from a community-based cohort. Model predictions of vertebral compressive loading and trunk muscle tension were highly correlated to previous in vivo measures of intradiscal pressure (IDP), vertebral loading from telemeterized implants and trunk muscle myoelectric activity recorded by electromyography (EMG). PMID:25901907
Agrawal, Vijay K; Sharma, Ruchi; Khadikar, Padmakar V
2002-09-01
QSAR studies on modelling of biological activity (hCAI) for a series of ureido and thioureido derivatives of aromatic/heterocyclic sulfonamides have been made using a pool of topological indices. Regression analysis of the data showed that excellent results were obtained in multiparametric correlations upon introduction of indicator parameters. The predictive abilities of the models are discussed using cross-validation parameters.
Ee, Su Im; Loh, Siew Yim; Chinna, Karuthan; Marret, Mary J
2016-01-01
To translate, culturally adapt, and examine psychometric properties of the Malay version Short Sensory Profile (SSP-M). Pretesting (n = 30) of the original English SSP established its applicability for use with Malaysian children aged 3-10 years. This was followed by the translation and cross-cultural adaptation of the SSP-M. Two forward and two back translations were compared and reviewed by a committee of 10 experts who validated the content of the SSP-M, before pilot testing (n = 30). The final SSP-M questionnaire was completed by 419 parents of typically developing children aged 3-10 years. Cronbach's alpha of each section of the SSP-M ranged from 0.73 to 0.93 and the intraclass correlation coefficient (ICC) indicated good reliability (0.62-0.93). The seven factor model of the SSP-M had an adequate fit with evidence of convergent and discriminant validity. We conclude that the SSP-M is a valid and reliable screening tool for use in Malaysia with Malay-speaking parents of children aged 3-10 years. The SSP-M enables Malay-speaking parents to answer the questionnaire with better reliability, and provides occupational therapists with a valid tool to screen for sensory processing difficulties.
Borloz, S; Trippolini, M A; Ballabeni, P; Luthi, F; Deriaz, O
2012-09-01
Functional subjective evaluation through questionnaire is fundamental, but not often realized in patients with back complaints, lacking validated tools. The Spinal Function Sort (SFS) was only validated in English. We aimed to translate, adapt and validate the French (SFS-F) and German (SFS-G) versions of the SFS. Three hundred and forty-four patients, experiencing various back complaints, were recruited in a French (n = 87) and a German-speaking (n = 257) center. Construct validity was estimated via correlations with SF-36 physical and mental scales, pain intensity and hospital anxiety and depression scales (HADS). Scale homogeneities were assessed by Cronbach's α. Test-retest reliability was assessed on 65 additional patients using intraclass correlation (IC). For the French and German translations, respectively, α were 0.98 and 0.98; IC 0.98 (95% CI: [0.97; 1.00]) and 0.94 (0.90; 0.98). Correlations with physical functioning were 0.63 (0.48; 0.74) and 0.67 (0.59; 0.73); with physical summary 0.60 (0.44; 0.72) and 0.52 (0.43; 0.61); with pain -0.33 (-0.51; -0.13) and -0.51 (-0.60; -0.42); with mental health -0.08 (-0.29; 0.14) and 0.25 (0.13; 0.36); with mental summary 0.01 (-0.21; 0.23) and 0.28 (0.16; 0.39); with depression -0.26 (-0.45; -0.05) and -0.42 (-0.52; -0.32); with anxiety -0.17 (-0.37; -0.04) and -0.45 (-0.54; -0.35). Reliability was excellent for both languages. Convergent validity was good with SF-36 physical scales, moderate with VAS pain. Divergent validity was low with SF-36 mental scales in both translated versions and with HADS for the SFS-F (moderate in SFS-G). Both versions seem to be valid and reliable for evaluating perceived functional capacity in patients with back complaints.
Poissant, Jocelyn; Wilson, Alastair J; Coltman, David W
2010-01-01
The independent evolution of the sexes may often be constrained if male and female homologous traits share a similar genetic architecture. Thus, cross-sex genetic covariance is assumed to play a key role in the evolution of sexual dimorphism (SD) with consequent impacts on sexual selection, population dynamics, and speciation processes. We compiled cross-sex genetic correlations (r(MF)) estimates from 114 sources to assess the extent to which the evolution of SD is typically constrained and test several specific hypotheses. First, we tested if r(MF) differed among trait types and especially between fitness components and other traits. We also tested the theoretical prediction of a negative relationship between r(MF) and SD based on the expectation that increases in SD should be facilitated by sex-specific genetic variance. We show that r(MF) is usually large and positive but that it is typically smaller for fitness components. This demonstrates that the evolution of SD is typically genetically constrained and that sex-specific selection coefficients may often be opposite in sign due to sub-optimal levels of SD. Most importantly, we confirm that sex-specific genetic variance is an important contributor to the evolution of SD by validating the prediction of a negative correlation between r(MF) and SD.
AbiHabib, Laurie E; Chemaitelly, Hiam S; Jaalouk, Lina Y; Karam, Nadim E
2011-07-01
To assess the feasibility, reliability, and construct validity of the Camberwell Assessment of Need for the Elderly (CANE) in identifying needs among community-dwelling older adults in South Lebanon with a view towards expanding ageing research in the country. A cross-sectional study was undertaken with 322 individuals, using the CANE, the EQ5d and a socio-demographic questionnaire. Reliability was determined through measuring internal consistency of the CANE. Construct validity was performed through examining CANE inter-item correlations, and comparing correlations with the EQ5d and socio-demographic indicators. A factor analysis was conducted using varimax orthogonal rotation. Cronbach alpha was 0.71. For construct validity, correlations were highest in items measuring needs in looking after the house and food (r = 0.557); company and intimate relationships (r = 0.572); and medication and written/verbal information (r = 0.586). Moderate correlations were found with EQ5d items assessing the same measure, including: EQ5d 'problems taking care of self' and CANE self-care (r = 0.578) and daytime activities (r = 0.523); EQ5d 'problems performing usual activities' and CANE daytime activities (r = 0.553), self-care (r = 0.511) and mobility (r = 0.500); and EQ5d 'problems while walking' and CANE mobility/falls (r = 0.509). Corresponding items of the CANE and EQ-5d were significantly correlated with similar socio-demographic variables. The factor analysis supported results obtained in the CANE inter-item correlations. The Arabic version of the CANE appears acceptable in assessing needs of older adults in South Lebanon. Given that the CANE is an interesting tool that promotes the integration of older persons' perspectives for appropriate interventions, further research is recommended to establish its validity and applicability in other communities in Lebanon and the region.
Trathitiphan, Warayos; Paholpak, Permsak; Sirichativapee, Winai; Wisanuyotin, Taweechok; Laupattarakasem, Pat; Sukhonthamarn, Kamolsak; Jeeravipoolvarn, Polasak; Kosuwon, Weerachai
2016-10-01
HOOS was developed as an extension of the Western Ontario and McMaster Universities' Osteoarthritis Index questionnaire for measuring symptoms and functional limitations related to the hip(s) of patients with osteoarthritis. To determine the validity and reliability of the Thai version of the Hip disability and Osteoarthritis Outcome Score (HOOS) vis-à-vis hip osteoarthritis, the original HOOS was translated into a Thai version of HOOS, according to international recommendations. Patients with hip osteoarthritis (n = 57; 25 males) were asked to complete the Thai version of HOOS twice: once then again after a 3-week interval. The test-retest reliability was analyzed using the intraclass correlation coefficient (ICC). Internal consistencies were analyzed using Cronbach's alpha, while the construct validity was tested by comparing the Thai HOOS with the Thai modified SF-36 and calculating the Spearman's rank correlation coefficients. The Thai HOOS produced good reliability (i.e., the ICC was greater than 0.9 in all five subscales). All of the Cronbach's alpha showed that the Thai HOOS had high internal consistency (Cronbach's alpha greater than 0.8), especially for the pain and ADL subscales (0.89 and 0.90, respectively). The Spearman's rank correlation for all five subscales of the Thai HOOS had moderate correlation with the Bodily Pain subscale of the Thai SF-36. The pain subscale of the Thai HOOS had a high correlation with the Vitality and Social Function subscales of the Thai SF-36 (r = 0.55 and 0.54)-with which the symptom subscale had a moderate correlation. The Thai version of HOOS had excellent internal consistency, excellent test-retest reliability, and good construct validity. It can be used as a reliable tool for assessing quality of life for patients with hip osteoarthritis in Thailand.
Parra-Rodríguez, Lorena; Szlejf, Claudia; García-González, Ana Isabel; Malmstrom, Theodore K; Cruz-Arenas, Esteban; Rosas-Carrasco, Oscar
2016-12-01
To cross-culturally adapt and validate the Spanish-language version of the SARC-F in Mexican community-dwelling older adults. Cross-sectional analysis of a prospective cohort. The FraDySMex study, a 2-round evaluation of community-dwelling adults from 2 municipalities in Mexico City. Participants were 487 men and women older than 60 years, living in the designated area in Mexico City. Information from questionnaires regarding demographic characteristics, comorbidities, mental status, nutritional status, dependence in activities of daily living, frailty, and quality of life. Objective measurements of muscle mass, strength and function were as follows: skeletal muscle mass index (SMI) was taken using dual-energy x-ray, grip strength using a hand dynamometer, 6-meter gait speed using a GAIT Rite instrumented walkway, peak torque and power for knee extension using a isokinetic dynamometer, lower extremity functioning measured by the Short Physical Performance Battery (SPPB), and balance using evaluation on a foam surface, with closed eyes, in the Modified Clinical Test of Sensory Integration. The SARC-F scale translated to Spanish and the consensus panels' criteria from European, international, and Asian sarcopenia working groups were applied to evaluate sarcopenia. The Spanish language version of the SARC-F scale showed reliability (Cronbach alfa = 0.641. All items in the scale correlated to the scale's total score, rho = 0.43 to 0.76), temporal consistency evaluated by test-retest (CCI = 0.80), criterion validity when compared to the consensus panels' criteria (high specificity and negative predictive values). The scale was also correlated to other measures related to sarcopenia (such as age, quality of life, self-rated health status, cognition, dependence in activities of daily living, nutritional status, depression, gait speed, grip strength, peak torque and power for knee extension, SPPB, balance, SMI, and frailty). The SARC-F scale was successfully adapted to Spanish language and validated in community-dwelling Mexican older adults. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Validation of hindi translation of DSM-5 level 1 cross-cutting symptom measure.
Goel, Ankit; Kataria, Dinesh
2018-04-01
The DSM-5 Level 1 Cross-Cutting Symptom Measure is a self- or informant-rated measure that assesses mental health domains which are important across psychiatric diagnoses. The absence of this self- or informant-administered instrument in Hindi, which is a major language in India, is an important limitation in using this scale. To translate the English version of the DSM-5 Level 1 Cross-Cutting Symptom Measure to Hindi and evaluate its psychometric properties. The study was conducted at a tertiary care hospital in Delhi. The DSM-5 Level 1 Cross-Cutting Symptom Measure was translated into Hindi using the World Health Organization's translation methodology. Mean and standard deviation were evaluated for continuous variables while for categorical variables frequency and percentages were calculated. The translated version was evaluated for cross-language equivalence, test-retest reliability, internal consistency, and split half reliability. Hindi version was found to have good cross-language equivalence and test-retest reliability at the level of items and domains. Twenty two of the 23 items and all the 23 items had a significant correlation (ρ < 0.001) in cross language concordance and test-retest reliability data, respectively. The Cronbach's alpha was 0.95, and the Spearman-Brown Sphericity value was 0.79 for the Hindi version. The present study shows that cross-language concordance, internal consistency, split-half reliability, and test-retest reliability of the Hindi version of the measure are excellent. Thus, the Hindi version of DSM-5 Level 1 Cross-Cutting Symptom Measure as translated in this study is a valid instrument. Copyright © 2018 Elsevier B.V. All rights reserved.
Hernandez, Matthew C; Aho, Johnathon M; Habermann, Elizabeth B; Choudhry, Asad J; Morris, David S; Zielinski, Martin D
2017-01-01
Determination and reporting of disease severity in emergency general surgery lacks standardization. Recently, the American Association for the Surgery of Trauma (AAST) proposed an anatomic severity grading system. We aimed to validate this system in patients with appendicitis and determine if cross-sectional imaging correlates with disease severity at operation. Patients 18 years or older undergoing treatment for acute appendicitis between 2013 and 2015 were identified. Baseline demographics, procedure types were recorded, and AAST grades were assigned based on intraoperative and radiologic findings. Outcomes including length of stay, 30-day mortality, and complications based on Clavien-Dindo categories and National Surgical Quality Improvement Program variables. Summary statistical univariate, nominal logistic, and standard least squares analyses were performed comparing AAST grade with key outcomes. Bland-Altman analysis compared operative findings with preoperative cross-sectional imaging to compare assigning grades. Three hundred thirty-four patients with mean (±SD) age of 39.3 years (±16.5) were included (53% men), and all patients had cross-sectional imaging. Two hundred ninety-nine underwent appendectomy, and 85% completed laparoscopic. Thirty-day mortality rate was 0.9%, complication rate was 21%. Increased (median [interquartile range, IQR]) AAST grade was recorded in patients with complications (2 [1-4]) compared with those without (1 [1-1], p = 0.001). For operative management, (median [IQR]) AAST grades were significantly associated with procedure type: laparoscopic (1 [1-1]), open (4 [2-5]), conversion to open (3 [1-4], p = 0.001). Increased (median [IQR]) AAST grades were significantly associated in nonoperative management: patients having a complication had a higher median AAST grade (4 [3-5]) compared with those without (3 [2-3], p = 0.001). Bland-Altman analysis comparing AAST grade and cross-sectional imaging demonstrated no difference (-0.02 ± 0.02; p = 0.2; coefficient of repeatability 0.9). The AAST grading system is valid in our population. Increased AAST grade is associated with open procedures, complications, and length of stay. The AAST emergency general surgery grade determined by preoperative imaging strongly correlated to operative findings. Epidemiologic/prognostic study, level III.
Hernandez, Matthew; Aho, Johnathan M.; Habermann, Elizabeth B.; Choudhry, Asad; Morris, David; Zielinski, Martin
2016-01-01
Background Determination and reporting of disease severity in emergency general surgery (EGS) lacks standardization. Recently, the American Association for the Surgery of Trauma (AAST) proposed an anatomic severity grading system. We aimed to validate this system in patients with appendicitis, and determine if cross sectional imaging correlates with disease severity at operation. Methods Patients 18 years or older undergoing treatment for acute appendicitis between 2013 and 2015 were identified. Baseline demographics, procedure types were recorded, and AAST grades were assigned based on intraoperative and radiologic findings. Outcomes including length of stay, 30 day mortality, and complications based on Clavien-Dindo categories and National Surgical Quality Improvement Program variables. Summary statistical univariate, nominal logistic and standard least squares analyses were performed comparing AAST grade with key outcomes. Bland-Altman analysis compared operative findings to preoperative cross sectional imaging to compare assigning grades. Results 334 patients with mean (±SD) age of 39.3 years (±16.5) were included (53% male) and all patients had cross sectional imaging. 299 underwent appendectomy, and 85% completed laparoscopic. 30 day mortality rate was 0.9%, complication rate 21%. Increased median [IQR] AAST grade was recorded in patients with complications 2 [1-4] compared to those without 1 [1-1], p=0.001. For operative management, a median [IQR] AAST grades were significantly associated with procedure type: laparoscopic 1 [1-1], open 4 [2-5] conversion to open 3 [1-4], p=0.001. Increased median [IQR] AAST grades were significantly associated in non-operative management: patients having a complication had a higher median AAST grade of 4 [3-5], compared to those without 3 [2-3], p=0.001. Bland Altman analysis comparing AAST grade and cross sectional imaging demonstrated no difference; −0.02 ±0.02 p = 0.2 coefficient of repeatability 0.9. Conclusions The AAST grading system is valid in our population. Increased AAST grade is associated with open procedures, complications, and length of stay. AAST EGS grade determined by preoperative imaging strongly correlated to operative findings. PMID:27805996
Odunaiya, Nse A; Louw, Quinette A; Grimmer, Karen
2017-06-01
Assessment of lifestyle risk factors must be culturally- and contextually relevant and available in local languages. This paper reports on a study which aimed to cross culturally adapt a composite lifestyle cardiovascular disease (CVD) risk factors questionnaire into an African language (Yoruba) and testing some of its psychometric properties such as content validity and test retest reliability in comparison to the original English version. This study utilized a cross sectional design. Translation of the English version of the questionnaire into Yoruba was undertaken using the guideline by Beaton et al. The translated instrument was presented to 21 rural adolescents to assess comprehensibility and clarity using a sample of convenience. A test retest reliability was conducted among 150 rural adolescents using a purposive sampling. Data was analyzed using intraclass correlation (ICC ) model 3, Cohen kappa statistics and prevalence rates. ICC ranged between 0.4-0.8. The Yoruba version was completed 15-20 minutes and was reported to be culturally appropriate and acceptable for rural Nigerian adolescents. The Yoruba translation of the Nigerian composite lifestyle risk factors questionnaire performs at least as well as the original English version in terms of content validity and reliability. It took a shorter time to complete therefore may be more relevant to rural adolescents.
NASA Astrophysics Data System (ADS)
Sarkar, Debdeep; Srivastava, Kumar Vaibhav
2017-02-01
In this paper, the concept of cross-correlation Green's functions (CGF) is used in conjunction with the finite difference time domain (FDTD) technique for calculation of envelope correlation coefficient (ECC) of any arbitrary MIMO antenna system over wide frequency band. Both frequency-domain (FD) and time-domain (TD) post-processing techniques are proposed for possible application with this FDTD-CGF scheme. The FDTD-CGF time-domain (FDTD-CGF-TD) scheme utilizes time-domain signal processing methods and exhibits significant reduction in ECC computation time as compared to the FDTD-CGF frequency domain (FDTD-CGF-FD) scheme, for high frequency-resolution requirements. The proposed FDTD-CGF based schemes can be applied for accurate and fast prediction of wideband ECC response, instead of the conventional scattering parameter based techniques which have several limitations. Numerical examples of the proposed FDTD-CGF techniques are provided for two-element MIMO systems involving thin-wire half-wavelength dipoles in parallel side-by-side as well as orthogonal arrangements. The results obtained from the FDTD-CGF techniques are compared with results from commercial electromagnetic solver Ansys HFSS, to verify the validity of proposed approach.
[Factor structure validity of the social capital scale used at baseline in the ELSA-Brasil study].
Souto, Ester Paiva; Vasconcelos, Ana Glória Godoi; Chor, Dora; Reichenheim, Michael E; Griep, Rosane Härter
2016-07-21
This study aims to analyze the factor structure of the Brazilian version of the Resource Generator (RG) scale, using baseline data from the Brazilian Longitudinal Health Study in Adults (ELSA-Brasil). Cross-validation was performed in three random subsamples. Exploratory factor analysis using exploratory structural equation models was conducted in the first two subsamples to diagnose the factor structure, and confirmatory factor analysis was used in the third to corroborate the model defined by the exploratory analyses. Based on the 31 initial items, the model with the best fit included 25 items distributed across three dimensions. They all presented satisfactory convergent validity (values greater than 0.50 for the extracted variance) and precision (values greater than 0.70 for compound reliability). All factor correlations were below 0.85, indicating full discriminative factor validity. The RG scale presents acceptable psychometric properties and can be used in populations with similar characteristics.
Janković, Slavenka; Vukićević, Jelica; Djordjević, Sanja; Janković, Janko; Marinković, Jelena; Erić, Miloš
2013-01-01
The Children's Dermatology Life Quality Index (CDLQI) evaluates the impact of skin diseases on the patient's quality of life. The purpose of the study was to translate and to validate the CDLQI into Serbian. The CDLQI was translated into Serbian following international recommendations for translation and cultural adaptation. The validation study was carried out on a large cohort of secondary schoolchildren who self-reported acne. Translating the CDLQI consisted of forward translation, reconciliation, back translation, back-translation review, and cognitive debriefing. The good internal consistency of the scale was demonstrated with a Cronbach alpha coefficient of 0.87. A Spearman correlation coefficient of 0.66 between the CDLQI and the Cardiff Acne Disability Index (CADI) was deemed satisfactory to demonstrate concurrent validity. The translation, cross-cultural adaptation, and psychometric qualities of the CDLQI were satisfactory, enabling its application in clinical practice and future studies.
Alzyoud, Sukaina; Veeranki, Sreenivas P.; Kheirallah, Khalid A.; Shotar, Ali M.; Pbert, Lori
2016-01-01
Introduction: Waterpipe use among adolescents has been increasing progressively. Yet no studies were reported to assess the validity and reliability of nicotine dependence scale. The current study aims to assess the validity and reliability of an Arabic version of the modified Waterpipe Tolerance Questionnaire WTQ among school-going adolescent waterpipe users. Methods: In a cross-sectional study conducted in Jordan, information on waterpipe use among 333 school-going adolescents aged 11-18 years was obtained using the Arabic version of the WTQ. An exploratory factor analysis and correlation matrices were conducted to assess validity and reliability of the WTQ. Results: The WTQ had a 0.73 alpha of internal consistency indicating moderate level of reliability. The scale showed multidimensionality with items loading on two factors, namely waterpipe consumption and morning smoking. Conclusion: This study report nicotine dependence level among school-going adolescents who identify themselves as waterpipe users using the WTQ. PMID:26383198
Cabrera, Esther; Zabalegui, Adelaida; Blanco, Ignacio
2011-01-15
The worry for falling ill has been described as a key element in the change of preventive attitudes. Levels of cancer worry not well fitted have been associated with inadequate adherence to preventive strategies. There is not a Spanish validated scale to evaluate the degree of worry for the cancer in our population. The aim of the present study was to perform the cross cultural adaptation and validation of the Cancer Worry Scale described by Lerman. A translation, re-translation of the Cancer Worry Scale to Spanish was done. Validation of the Spanish scale was performed by means of the factorial analysis of principal components with the rotation varimax test in a sample of 200 healthy women with family history of breast cancer. The Escala de Preocupación por el Cáncer (EPC) is the Spanish version of the Cancer Worry Scale and it contains 6 items with a total value ranging from 6 (minimal worry) to 24 (maximum worry). The analysis of content validity demonstrated that the EPC is conceptually equivalent to the original scale. The factorial analysis showed a unique factor that explains 53.07% of the variance confirming the unique dimension. The EPC presented good reliability test - re-test with an Intraclass Correlation Coefficient of 0.777. The Cronbach's alpha was 0.835 for the complete of the scale. The EPC is a validated Spanish scale to measure the cancer worry in healthy individuals, which shows a correct content validity and reliability. Copyright © 2010 Elsevier España, S.L. All rights reserved.
Validation of Metrics as Error Predictors
NASA Astrophysics Data System (ADS)
Mendling, Jan
In this chapter, we test the validity of metrics that were defined in the previous chapter for predicting errors in EPC business process models. In Section 5.1, we provide an overview of how the analysis data is generated. Section 5.2 describes the sample of EPCs from practice that we use for the analysis. Here we discuss a disaggregation by the EPC model group and by error as well as a correlation analysis between metrics and error. Based on this sample, we calculate a logistic regression model for predicting error probability with the metrics as input variables in Section 5.3. In Section 5.4, we then test the regression function for an independent sample of EPC models from textbooks as a cross-validation. Section 5.5 summarizes the findings.
Prediction of Maximal Oxygen Uptake by Six-Minute Walk Test and Body Mass Index in Healthy Boys.
Jalili, Majid; Nazem, Farzad; Sazvar, Akbar; Ranjbar, Kamal
2018-05-14
To develop an equation to predict maximal oxygen uptake (VO2max) based on the 6-minute walk test (6MWT) and body composition in healthy boys. Direct VO2max, 6-minute walk distance, and anthropometric characteristics were measured in 349 healthy boys (12.49 ± 2.72 years). Multiple regression analysis was used to generate VO2max prediction equations. Cross-validation of the VO2max prediction equations was assessed with predicted residual sum of squares statistics. Pearson correlation was used to assess the correlation between measured and predicted VO2max. Objectively measured VO2max had a significant correlation with demographic and 6MWT characteristics (R = 0.11-0.723, P < .01). Multiple regression analysis revealed the following VO2max prediction equation: VO2max (mL/kg/min) = 12.701 + (0.06 × 6-minute walk distance m ) - (0.732 × body mass index kg/m2 ) (R 2 = 0.79, standard error of the estimate [SEE] = 2.91 mL/kg/min, %SEE = 6.9%). There was strong correlation between measured and predicted VO2max (r = 0.875, P < .001). Cross-validation revealed minimal shrinkage (R 2 p = 0.78 and predicted residual sum of squares SEE = 2.99 mL/kg/min). This study provides a relatively accurate and convenient VO2max prediction equation based on the 6MWT and body mass index in healthy boys. This model can be used for evaluation of cardiorespiratory fitness of boys in different settings. Copyright © 2018 Elsevier Inc. All rights reserved.
Automated measurement of vocal fold vibratory asymmetry from high-speed videoendoscopy recordings.
Mehta, Daryush D; Deliyski, Dimitar D; Quatieri, Thomas F; Hillman, Robert E
2011-02-01
In prior work, a manually derived measure of vocal fold vibratory phase asymmetry correlated to varying degrees with visual judgments made from laryngeal high-speed videoendoscopy (HSV) recordings. This investigation extended this work by establishing an automated HSV-based framework to quantify 3 categories of vocal fold vibratory asymmetry. HSV-based analysis provided for cycle-to-cycle estimates of left-right phase asymmetry, left-right amplitude asymmetry, and axis shift during glottal closure for 52 speakers with no vocal pathology producing comfortable and pressed phonation. An initial cross-validation of the automated left-right phase asymmetry measure was performed by correlating the measure with other objective and subjective assessments of phase asymmetry. Vocal fold vibratory asymmetry was exhibited to a similar extent in both comfortable and pressed phonations. The automated measure of left-right phase asymmetry strongly correlated with manually derived measures and moderately correlated with visual-perceptual ratings. Correlations with the visual-perceptual ratings remained relatively consistent as the automated measure was derived from kymograms taken at different glottal locations. An automated HSV-based framework for the quantification of vocal fold vibratory asymmetry was developed and initially validated. This framework serves as a platform for investigating relationships between vocal fold tissue motion and acoustic measures of voice function.
Nauleau, Pierre; Apostolakis, Iason; McGarry, Matthew; Konofagou, Elisa
2018-05-29
The stiffness of the arteries is known to be an indicator of the progression of various cardiovascular diseases. Clinically, the pulse wave velocity (PWV) is used as a surrogate for arterial stiffness. Pulse wave imaging (PWI) is a non-invasive, ultrasound-based imaging technique capable of mapping the motion of the vessel walls, allowing the local assessment of arterial properties. Conventionally, a distinctive feature of the displacement wave (e.g. the 50% upstroke) is tracked across the map to estimate the PWV. However, the presence of reflections, such as those generated at the carotid bifurcation, can bias the PWV estimation. In this paper, we propose a two-step cross-correlation based method to characterize arteries using the information available in the PWI spatio-temporal map. First, the area under the cross-correlation curve is proposed as an index for locating the regions of different properties. Second, a local peak of the cross-correlation function is tracked to obtain a less biased estimate of the PWV. Three series of experiments were conducted in phantoms to evaluate the capabilities of the proposed method compared with the conventional method. In the ideal case of a homogeneous phantom, the two methods performed similarly and correctly estimated the PWV. In the presence of reflections, the proposed method provided a more accurate estimate than conventional processing: e.g. for the soft phantom, biases of -0.27 and -0.71 m · s -1 were observed. In a third series of experiments, the correlation-based method was able to locate two regions of different properties with an error smaller than 1 mm. It also provided more accurate PWV estimates than conventional processing (biases: -0.12 versus -0.26 m · s -1 ). Finally, the in vivo feasibility of the proposed method was demonstrated in eleven healthy subjects. The results indicate that the correlation-based method might be less precise in vivo but more accurate than the conventional method.
Wakeling, Helen C
2007-09-01
This study examined the reliability and validity of the Social Problem-Solving Inventory--Revised (SPSI-R; D'Zurilla, Nezu, & Maydeu-Olivares, 2002) with a population of incarcerated sexual offenders. An availability sample of 499 adult male sexual offenders was used. The SPSI-R had good reliability measured by internal consistency and test-retest reliability, and adequate validity. Construct validity was determined via factor analysis. An exploratory factor analysis extracted a two-factor model. This model was then tested against the theory-driven five-factor model using confirmatory factor analysis. The five-factor model was selected as the better fitting of the two, and confirmed the model according to social problem-solving theory (D'Zurilla & Nezu, 1982). The SPSI-R had good convergent validity; significant correlations were found between SPSI-R subscales and measures of self-esteem, impulsivity, and locus of control. SPSI-R subscales were however found to significantly correlate with a measure of socially desirable responding. This finding is discussed in relation to recent research suggesting that impression management may not invalidate self-report measures (e.g. Mills & Kroner, 2005). The SPSI-R was sensitive to sexual offender intervention, with problem-solving improving pre to post-treatment in both rapists and child molesters. The study concludes that the SPSI-R is a reasonably internally valid and appropriate tool to assess problem-solving in sexual offenders. However future research should cross-validate the SPSI-R with other behavioural outcomes to examine the external validity of the measure. Furthermore, future research should utilise a control group to determine treatment impact.
Yang, Baoqi; Chen, Guo; Yang, Qing; Yan, Xiaoxiao; Zhang, Zhaoxia; Murrell, Dédée F; Zhang, Furen
2017-02-02
The autoimmune bullous diseases quality of life (ABQOL) questionnaire was recently developed by an Australian group and has been validated in Australian and North American patient cohorts. It is a 17-item, multidimensional, self-administered English questionnaire. The study aimed to validate the Chinese version of the ABQOL questionnaire and evaluate the reliability in Chinese patients. The Chinese version of the ABQOL questionnaire was produced by forward-backward translation and cross-cultural adaptation of the original English version. The ABQOL questionnaire was then distributed to a total of 101 patients with autoimmune bullous diseases (AIBDs) together with the Dermatology Life Quality Index (DLQI) and the 36-item Short Form Health Survey (SF-36). Validity was analyzed across a range of indices and reliability was assessed using internal consistency and test-retest methods. The Chinese version of the ABQOL questionnaire has a high internal consistency (Cronbach's alpha coefficient, 0.88) and test-retest reliability (the intraclass correlation coefficient, 0.87). Face and content validity were satisfactory. Convergent validity testing showed that the correlation coefficients for the ABQOL and DLQI was 0.77 and for the ABQOL and SF-36 was -0.62. In terms of discriminant validity, there was no significant difference between the proportions of insensitive items in ABQOL and DLQI (p = 0.236). There was no significant difference between the proportions of insensitive items in ABQOL and SF-36 (p = 0.823). The Chinese version of the ABQOL questionnaire has adequate validity and reliability. It may constitute a useful instrument to measure disease burden in Chinese patients with AIBDs.
Competency measurements: testing convergent validity for two measures.
Cowin, Leanne S; Hengstberger-Sims, Cecily; Eagar, Sandy C; Gregory, Linda; Andrew, Sharon; Rolley, John
2008-11-01
This paper is a report of a study to investigate whether the Australian National Competency Standards for Registered Nurses demonstrate correlations with the Finnish Nurse Competency Scale. Competency assessment has become popular as a key regulatory requirement and performance indicator. The term competency, however, does not have a globally accepted definition and this has the potential to create controversy, ambiguity and confusion. Variations in meaning and definitions adopted in workplaces and educational settings will affect the interpretation of research findings and have implications for the nursing profession. A non-experimental cross-sectional survey design was used with a convenience sample of 116 new graduate nurses in 2005. The second version of the Australian National Competency Standards and the Nurse Competency Scale was used to elicit responses to self-assessed competency in the transitional year (first year as a Registered Nurse). Correlational analysis of self-assessed levels of competence revealed a relationship between the Australian National Competency Standards (ANCI) and the Nurse Competency Scale (NCS). The correlational relation between ANCI domains and NCS factors suggests that these scales are indeed used to measure related dimensions. A statistically significant relationship (r = 0.75) was found between the two competency measures. Although the finding of convergent validity is insufficient to establish construct validity for competency as used in both measures in this study, it is an important step towards this goal. Future studies on relationships between competencies must take into account the validity and reliability of the tools.
Validation and reliability of the Physical Activity Scale for the Elderly in Chinese population.
Ngai, Shirley P C; Cheung, Roy T H; Lam, Priscillia L; Chiu, Joseph K W; Fung, Eric Y H
2012-05-01
Physical Activity Scale for the Elderly (PASE) is a widely used questionnaire in epidemiological studies for assessing the physical activity level of elderly. This study aims to translate and validate PASE in Chinese population. Cross-sectional study. Chinese elderly aged 65 or above. The original English version of PASE was translated into Chinese (PASE-C) following standardized translation procedures. Ninety Chinese elderly aged 65 or above were recruited in the community. Test-retest reliability was determined by comparing the scores obtained from two separate administrations by the intraclass correlation coefficient. Validity was evaluated by Spearman's rank correlation coefficients between PASE and Medical Outcome Survey 36-Item Short Form Health Survey (SF-36), grip strength, single-leg-stance, 5 times sit-to-stand and 10-m walk. PASE-C demonstrated good test-retest reliability (intraclass correlation coefficient = 0.81). Fair to moderate association were found between PASE-C and most of the subscales of SF-36 (rs = 0.285 to 0.578, p < 0.01), grip strength (rs = 0.405 to 0.426, p < 0.001), single-leg-stance (rs = 0.470 to 0.548, p < 0.001), 5 times sit-to-stand (rs = -0.33, p = 0.001) and 10-m walk (rs = -0.281, p = 0.007). PASE-C is a reliable and valid instrument for assessing the physical activity level of elderly in Chinese population.