Sample records for crown ethers 18-crown-6

  1. Electron spin resonance and electron spin echo modulation of n-doxylstearic acid and N,N,N',N'-tetramethylbenzidine photoionization in sodium versus lithium dodecyl sulfate micellar solutions: effect of 15-crown-5 and 18-crown-6 ether addition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baglioni, P.; Rivara-Minten, E.; Kevan, L.

    1988-08-11

    Electron spin echo modulation and electron spin resonance spectra of photogenerated N,N,N',N'-tetramethylbenzidine (TMB) cation radical and n-doxylstearic acids (n-DSA) in frozen micellar solutions of sodium and lithium dodecyl sulfate containing 15-crown-5 and 18-crown-6 ethers in D/sub 2/O have been studied as a function of crown ether concentration. Modulation effects due to N-DSA with water deuteriums give direct evidence that both crown ethers are mainly located at the micellar interface and that this causes a decrease of the hydration of the micellar interface. Crown ether complexation constants for sodium and lithium micellar counterions are reported and show that 18-crown-6 > 15-crown-5more » for sodium counterion and 15-crown-5 > 18-crown-6 for lithium counterion. Modulation effects from TMB/sup +/ interaction with water deuteriums indicate that the TMB molecule moves toward the micelle interfacial region when sodium or lithium cations are complexed by crown ethers. The TMB/sup +/ yield upon TMB photoionization increases by about 10% with crown ether addition for SDS and LDS micellar systems, but it is greater if the absolute values for the LDS system are compared to those for the SDS micellar system. This behavior correlates with the strength of TMB/sup +/-water interactions and suggests that the main factor in the photoionization efficiency is the photocation-water interaction.« less

  2. SYNTHESIS OF NOVEL CROWN ETHERS BEARING THE exo-cis-2,3-NORBORNYL GROUP AS POTENTIAL Na+ AND K+ EXTRACTANTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robeson, R.M.; Bonnesen, P.

    2007-01-01

    The synthesis of a series of novel dinorbornyl-16-crown-5 and dinorbornyl-18-crown-6 ethers that incorporate the exo-cis-2,3-norbornyl moiety within the macrocycle framework is described. The key starting material for the crown ethers, exo-cis-2,3-norbornanediol, was successfully prepared on a large (>30g) scale in 88% yield from norbornylene by osmium tetroxide-catalyzed hydroxylation. The syn and anti isomers of the dinorbornyl-16-crown-5 ether family were prepared using diethylene glycol with ring closure achieved using a methallyl linkage. The isomers cis-syn-cis and cis-anti-cis di-norbornano-15-methyleno-16-crown-5 (6A and 6B) could be separated using column chromatography, and a single crystal of the syn isomer 6A suitable for X-ray crystal structuremore » analysis was obtained, thereby confi rming the syn orientation. The syn and anti isomers of the dinorbornyl-18-crown-6 ether family were successfully prepared employing a different synthetic strategy, involving the potassium–templated cyclization of two bis-hydroxyethoxy-substituted exo-cis-2,3-norbornyl groups under high dilution conditions. Attempts to fully separate cis-syn-cis di-norbornano-18-crown-6 (10A) and cis-anti-cis di-norbornano-18-crown-6 (10B) from one another using column chromatography were unsuccessful. All intermediates and products were checked for purity using either thin layer chromatography or gas chromatography, and characterized by proton and carbon NMR. Crown ethers 6AB and 10AB are to our knowledge the fi rst crown ethers to incorporate the exo-cis-2,3-norbornyl moiety into the crown ring to be successfully synthesized and characterized.« less

  3. Crown Ethers in Nonaqueous Electrolytes for Lithium/Air Batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Wu; Xiao, Jie; Wang, Deyu

    2010-02-04

    The effects of three crown ethers, 12-crown-4, 15-crown-5, and 18-crown-6, as additives and co-solvents in non-aqueous electrolytes on the cell performance of primary Li/air batteries operated in a dry air environment were investigated. Crown ethers have large effects on the discharge performance of non-aqueous electrolytes in Li/air batteries. A small amount (normally less than 10% by weight or volume in electrolytes) of 12-Crown-4 and 15-crown-5 reduces the battery performance and a minimum discharge capacity appears at the crown ether content of ca. 5% in the electrolytes. However, when the content increases to about 15%, both crown ethers improve the capacitymore » of Li/air cells by about 28% and 16%, respectively. 15-Crown-5 based electrolytes even show a maximum discharge capacity in the crown ether content range from 10% to 15%. On the other hand, the increase of 18-crown-6 amount in the electrolytes continuously lowers of the cell performance. The different battery performances of these three crown ethers in electrolytes are explained by the combined effects from the electrolytes’ contact angle, oxygen solubility, viscosity, ionic conductivity, and the stability of complexes formed between crown ether molecules and lithium ions.« less

  4. Change in the Gibbs energy of 18-crown-6 ether transfer from methanol to methanol-acetonitrile mixtures at 298 K

    NASA Astrophysics Data System (ADS)

    Kuz'mina, I. A.; Usacheva, T. R.; Kuz'mina, K. I.; Volkova, M. A.; Sharnin, V. A.

    2015-01-01

    The Gibbs energies of the transfer of 18-crown-6 ether from methanol to its mixtures with acetonitrile (χAN = 0.0-1.0 mole fraction) are determined by means of interphase distribution at 298 K. The effect the solvent composition has on the thermodynamic characteristics of the solvation of 18-crown-6 ether is analyzed. An increase in the content of acetonitrile in the mixed solvent enhances the solvation of crown ether due to changes in the energy of the solution. Resolvation of the macrocycle is assumed to be complete at acetonitrile concentrations higher than 0.6 mole fraction.

  5. Ionic complexation of N 2O 4 by 18-crown-6

    NASA Astrophysics Data System (ADS)

    Ricard, S.; Audet, P.; Savoie, R.

    1988-08-01

    An ionic complex has been obtained from N 2O 4 in the presence of the macrocyclic ether 18-crown-6. This crystalline compound has been shown from its Raman spectrum to have the formula NO +·crown·H(NO 3) 2-, with the nitrosonium ion closely associated with the crown ether rather than with the hydrogen dinitrate accompanying ion. This adduct decomposes readily in moist air to give the known complex (HNO 3·H 2O) 2·crown.

  6. The Discovery of Crown Ethers

    NASA Astrophysics Data System (ADS)

    Pedersen, Charles J.

    1988-07-01

    The discovery of the crown ethers stemmed from efforts to control the catalytic activity of vanadium and copper by complexation with multidentate ligands. The first crown ether, 2,3,11,12-dibenzo-1,4,7,10,13,16-hexaoxacyclo-octadeca-2,11-diene, was obtained in 0.4% yield during an attempt to prepare a phenolic ligand from catechol and bis(2-chloroethyl)ether. This compound, which complexed with the sodium cation, was the first compound known to display such activity and became known as dibenzo-18-crown-6, an 18-atom heterocycle containing 6 oxygen atoms. Some 60 related compounds were made involving heterocyclic rings containing 12 to 60 atoms including 4 and 10 oxygen atoms. There are optimum polyether ring sizes for the different alkali metal cations: 15 to 18 for sodium, 18 for potassium, and 18 to 21 for cesium. Complexes having polyether to cation ratios of 1:1, 3:2, and 2:1 were prepared. Solubilization of inorganic salts in aprotic solvents, especially by saturated crown ethers, was demonstrated.

  7. Antitumor potential of crown ethers: structure-activity relationships, cell cycle disturbances, and cell death studies of a series of ionophores.

    PubMed

    Marjanović, Marko; Kralj, Marijeta; Supek, Fran; Frkanec, Leo; Piantanida, Ivo; Smuc, Tomislav; Tusek-Bozić, Ljerka

    2007-03-08

    The present paper demonstrates the antiproliferative ability and structure-activity relationships (SAR) of 14 crown and aza-crown ether analogues on five tumor-cell types. The most active compounds were di-tert-butyldicyclohexano-18-crown-6 (3), which exhibited cytotoxicity in the submicromolar range, and di-tert-butyldibenzo-18-crown-6 (5) (IC50 values of approximately 2 microM). Also, 3 and 5 induced marked influence on the cell cycle phase distribution--strong G1 arrest, followed by the induction of apoptosis. A computational SAR modeling effort offers insight into possible mechanisms of crown ether biological activity, presumably involving penetration into cell membranes, and points out structural features of molecules important for this activity. The results reveal that crown ethers possess marked tumor-cell growth inhibitory activity, the extent of which depends on the characteristics of the hydrophilic macrocylic cavity and the surrounding hydrophobic ring. Our work supports the hypothesis that crown ether compounds inhibit tumor-cell growth by disrupting potassium ion homeostasis, which in turn leads to cell cycle perturbations and apoptosis.

  8. The interaction between ketamine and some crown ethers in common organic solvents studied by NMR: The effect of donating atoms and ligand structure

    NASA Astrophysics Data System (ADS)

    Chekin, Fereshteh; Bordbar, Maryam; Fathollahi, Yaghoub; Alizadeh, Naader

    2006-02-01

    1H NMR spectroscopy was used to investigate the stoichiometry and stability of the drug ketamine cation complexes with some crown ethers, such as 15-crown-5 (15C5), aza-15-crown-5 (A15C5), 18-crown-6 (18C6), aza-18-crown-6 (A18C6), diaza-18-crown-6 (DA18C6), dibenzyl-diaza-18-crown-6 (DBzDA18C6) and cryptant [2,2,2] (C222) in acetonitrile (AN), dimethylsulfoxide (DMSO) and methanol (MeOH) at 27 °C. In order to evaluate the formation constants of the ketamine cation complexes, the CH 3 protons chemical shift (on the nitrogen atom of ketamine) was measured as function of ligand/ketamine mole ratio. The formation constant of resulting complexes were calculated by the computer fitting of chemical shift versus mole ratio data to appropriate equations. A significant chemical shift variation was not observed for 15C5 and 18C6. The stoichiometry of the mono aza and diaza ligands are 1:1 and 1:2 (ligand/ketamine), respectively. In all of the solvents studied, DA18C6 formed more stable complexes than other ligands. The solvent effect on the stability of these complexes is discussed.

  9. Crown ether stereoisomerism: Implications in metal ion extraction and ionic liquid design

    NASA Astrophysics Data System (ADS)

    Pawlak, Alan J.

    Since their discovery more than four decades ago, crown ethers (CEs) have been the subject of intense investigation in a number of fields. Although many of the structural features that govern the behavior of these compounds have been thoroughly explored, the effect of their stereochemistry has received relatively little attention. In the present work, crown ether stereochemistry is shown to have important implications in both the design of ternary (i.e., three-component) ionic liquids (TILs) and metal ion extraction. Specifically, as a first step toward the development of guidelines for the rational design of ternary ionic liquids employing crown ethers as the neutral extractant, a systematic examination of the effect of crown ether stereochemistry (employing dicyclohexano-18-crown-6 (DCH18C6) as a representative crown compound), along with ring size, the nature and number of donor atoms, and the presence of functional groups, on the thermal properties (i.e., melting point or glass transition; decomposition or evaporation) of these compounds was carried out. Stereochemistry was found to have no appreciable impact on the onset temperature for mass loss. Rather, molecular weight and aromaticity were found to be more influential. Stereochemistry was, however, found to significantly affect the melting point of a TIL prepared from it; while the metal-CE formation constant, which varies with stereoisomer was observed to determine the onset temperature for mass loss of the TIL. To explore the implications of crown ether stereoisomerism in metal ion extraction, the formation constants for alkaline earth cation complexes with the isomers of DCH18C6 and selected stereoisomers of di-tert-butylcyclohexano-18-crown-6 (DtBuCH18C6) were measured. These values were found to vary inversely with the ligand strain (i.e., reorganizational) energy for the isomer, as determined by molecular mechanics calculations. Using this relationship (along with additional identification methods), three isomers of DtBuCH18C6, which were separated by preparative LC, were definitively identified. Three additional isomers were partially identified.

  10. Inhibition of Fibrillar Assemblies of l-Phenylalanine by Crown Ethers: A Potential Approach toward Phenylketonuria.

    PubMed

    Banik, Debasis; Dutta, Rupam; Banerjee, Pavel; Kundu, Sangita; Sarkar, Nilmoni

    2016-08-11

    In this article, our aim is to investigate the interaction of l-phenylalanine (l-Phe) fibrils with crown ethers (CEs). For this purpose, two different CEs (15-Crown-5 (15C5) and 18-Crown-6 (18C6)) were used. Interestingly, we have observed that both CEs have the ability to arrest fibril formation. However, 18C6 was found to be a better candidate compared to 15C5. Field emission scanning electron microscopy and fluorescence lifetime imaging microscopy were used to monitor the fibril-arresting kinetics of CEs. The arresting process was further confirmed by fluorescence correlation spectroscopy and nuclear magnetic resonance studies.

  11. Could LogP be a principal determinant of biological activity in 18-crown-6 ethers? Synthesis of biologically active adamantane-substituted diaza-crowns.

    PubMed

    Supek, Fran; Ramljak, Tatjana Šumanovac; Marjanović, Marko; Buljubašić, Maja; Kragol, Goran; Ilić, Nataša; Smuc, Tomislav; Zahradka, Davor; Mlinarić-Majerski, Kata; Kralj, Marijeta

    2011-08-01

    18-crown-6 ethers are known to exert their biological activity by transporting K(+) ions across cell membranes. Using non-linear Support Vector Machines regression, we searched for structural features that influence antiproliferative activity in a diverse set of 19 known oxa-, monoaza- and diaza-18-crown-6 ethers. Here, we show that the logP of the molecule is the most important molecular descriptor, among ∼1300 tested descriptors, in determining biological potency (R(2)(cv) = 0.704). The optimal logP was at 5.5 (Ghose-Crippen ALOGP estimate) while both higher and lower values were detrimental to biological potency. After controlling for logP, we found that the antiproliferative activity of the molecule was generally not affected by side chain length, molecular symmetry, or presence of side chain amide links. To validate this QSAR model, we synthesized six novel, highly lipophilic diaza-18-crown-6 derivatives with adamantane moieties attached to the side arms. These compounds have near-optimal logP values and consequently exhibit strong growth inhibition in various human cancer cell lines and a bacterial system. The bioactivities of different diaza-18-crown-6 analogs in Bacillus subtilis and cancer cells were correlated, suggesting conserved molecular features may be mediating the cytotoxic response. We conclude that relying primarily on the logP is a sensible strategy in preparing future 18-crown-6 analogs with optimized biological activity. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  12. Capillary electrophoresis separation of peptide diastereomers that contain methionine sulfoxide by dual cyclodextrin-crown ether systems.

    PubMed

    Zhu, Qingfu; Heinemann, Stefan H; Schönherr, Roland; Scriba, Gerhard K E

    2014-12-01

    A dual-selector system employing achiral crown ethers in combination with cyclodextrins has been developed for the separation of peptide diastereomers that contain methionine sulfoxide. The combinations of the crown ethers 15-crown-5, 18-crown-6, Kryptofix® 21 and Kryptofix® 22 and β-cyclodextrin, carboxymethyl-β-cyclodextrin, and sulfated β-cyclodextrin were screened at pH 2.5 and pH 8.0 using a 40/50.2 cm, 50 μm id fused-silica capillary and a separation voltage of 25 kV. No diastereomer separation was observed in the sole presence of crown ethers, while only sulfated β-cyclodextrin was able to resolve some peptide diastereomers at pH 8.0. Depending on the amino acid sequence of the peptide and the applied cyclodextrin, the addition of crown ethers, especially the Krpytofix® diaza-crown ethers, resulted in significantly enhanced chiral recognition. Keeping one selector of the dual system constant, increasing concentrations of the second selector resulted in increased peak resolution and analyte migration time for peptide-crown ether-cyclodextrin combinations. The simultaneous diastereomer separation of three structurally related peptides was achieved using the dual selector system. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Photodissociation of Non-Covalent Peptide-Crown Ether Complexes

    PubMed Central

    Wilson, Jeffrey J.; Kirkovits, Gregory J.; Sessler, Jonathan L.; Brodbelt, Jennifer S.

    2008-01-01

    Highly chromogenic 18-crown-6-dipyrrolylquinoxaline coordinates primary amines of peptides, forming non-covalent complexes that can be transferred to the gas phase by electrospray ionization. The appended chromogenic crown ether facilitates efficient energy transfer to the peptide upon ultraviolet irradiation in the gas phase, resulting in diagnostic peptide fragmentation. Collisional activated dissociation (CAD) and infrared multiphoton dissociation (IRMPD) of these non-covalent complexes results only in their disassembly with the charge retained on either the peptide or crown ether, yielding no sequence ions. Upon UV photon absorption the intermolecular energy transfer is facilitated by the fast activation time scale of UVPD (< 10 ns) and by the collectively strong hydrogen bonding between the crown ether and peptide, thus allowing effective transfer of energy to the peptide moiety prior to disruption of the intermolecular hydrogen bonds. PMID:18077179

  14. Coordination trends in alkali metal crown ether uranyl halide complexes: the series [A(crown)]2[UO(2)X(4)] where A=Li, Na, K and X=Cl, Br.

    PubMed

    Danis, J A; Lin, M R; Scott, B L; Eichhorn, B W; Runde, W H

    2001-07-02

    UO(2)(C(2)H(3)O(2))(2).2H(2)O reacts with AX or A(C(2)H(3)O(2) or ClO(4)) (where A = Li, Na, K; X = Cl, Br) and crown ethers in HCl or HBr aqueous solutions to give the sandwich-type compounds [K(18-crown-6)](2)[UO(2)Cl(4)] (1), [K(18-crown-6)](2)[UO(2)Br(4)] (2), [Na(15-crown-5)](2)[UO(2)Cl(4)] (3), [Na(15-crown-5)](2)[UO(2)Br(4)] (4), [Li(12-crown-4)](2)[UO(2)Cl(4)] (5), and [Li(12-crown-4)](2)[UO(2)Br(4)] (6). The compounds have been characterized by single-crystal X-ray diffraction, powder diffraction, elemental analysis, IR, and Raman spectroscopy. The [UO(2)X(4)](2-) ions coordinate to two [A(crown)](+) cations through the four halides only (2), through two halides only (3), through the two uranyl oxygens and two halides (3, 4), or through the two uranyl oxygen atoms only (5, 6). Raman spectra reveal nu(U-O) values that correlate with expected trends. The structural trends are discussed within the context of classical principles of hard-soft acid-base theory.

  15. Ultrasound promoted N-alkylation of pyrrole using potassium superoxide as base in crown ether.

    PubMed

    Yim, E S; Park, M K; Han, B H

    1997-04-01

    Ultrasound accelerates the N-alkylation of pyrrole by alkylating reagents using potassium superoxide as base in the presence of 18-crown-6. A much lower yield of N-alkylated pyrrole was realized in the absence of ultrasound. N-alkylating reagents employed for pyrrole are methyl iodide, ethyl bromide, benzyl bromide, as well as acrylonitrile allyl cyanide and methyl acrylate. In an extension of this work, we have found that ultrasound was not necessary for the N-alkylation of indole and alkyl amine, such as diphenyl amine and piperidine with alkyl halides using our reagents. In all cases we observed that the 18-crown-6 catalyzed N-alkylation reaction gives higher yields of N-alkylated products than that without crown ether, when potassium superoxide was used as base. These observations are probably due to the potassium-crown complex which can be released when the reaction goes to completion.

  16. Aqua complexes of 18—crown-6 with H 3PO 4, H 2TiF 6, and HNO 3: synthesis and vibrational spectra

    NASA Astrophysics Data System (ADS)

    Chénevert, R.; Rodrigue, A.; Chamberland, D.; Ouellet, J.; Savoie, R.

    1985-11-01

    Neutral-component complexes of 2:3:1 (acid:water:18-crown-6) stoichiometry have been obtained with H 3PO 4 and H 2TiF 6. These adducts have been studied by infrared and Raman spectroscopy, along with the corresponding (HNO 3-H 1O) 2-18-crown-6 complex, whose synthesis has already been reported. The spectra indicate that the crown ether has a highly regular conformation in these complexes. In those with H 3PO 4 and HNO 3, the binding of the acid molecule to the ether takes place through a H 2O linker, the strength of the XOH⋯OH 2 hydrogen bond being directly related to the p K a of the acid. With HNO 3, the acidic proton appears to be delocalized between the two oxygen atoms, giving a pseudo H 2O + ion whereas in the corresponding deuterocompound the D atom remains associated with the acid.

  17. 4-Fluoro-anilinium tetra-chloridoferrate(III) 18-crown-6 clathrate.

    PubMed

    Ge, Jia-Zhen; Zhao, Min-Min

    2010-06-05

    The reaction of 4-fluoro-aniline hydro-chloride, 18-crown-6 and ferric chloride in methano-lic solution yields the title compound, (C(6)H(7)FN)[FeCl(4)]·C(12)H(24)O(6), which has an unusual supramolecular structure. N-H⋯O hydrogen-bonding inter-actions between the NH(3) (+) substituents of the 4-fluoro-anilinium cations and the O atoms of the crown ether mol-ecules result in a rotator-stator-like structure.

  18. Studies of flerovium and element 115 homologs with macrocyclic extractants

    NASA Astrophysics Data System (ADS)

    Despotopulos, John Dustin

    Study of the chemistry of the heaviest elements, Z ? 104, poses a unique challenge due to their low production cross-sections and short half-lives. Chemistry also must be studied on the one-atom-at-a-time scale, requiring automated, fast, and very efficient chemical schemes. Recent studies of the chemical behavior of copernicium (Cn, element 112) and flerovium (Fl, element 114) together with the discovery of isotopes of these elements with half-lives suitable for chemical studies have spurred a renewed interest in the development of rapid systems designed to study the chemical properties of elements with Z ≥ 114. This dissertation explores both extraction chromatography and solvent extraction as methods for development of a rapid chemical separation scheme for the homologs of flerovium (Pb, Sn, Hg) and element 115 (Bi, Sb), with the goal of developing a chemical scheme that, in the future, can be applied to on-line chemistry of both Fl and element 115. Macrocyclic extractants, specifically crown ethers and their derivatives, were chosen for these studies. Carrier-free radionuclides, used in these studies, of the homologs of Fl and element 115 were obtained by proton activation of high purity metal foils at the Lawrence Livermore National Laboratory (LLNL) Center for Accelerator Mass Spectrometry (CAMS): natIn(p,n)113Sn, natSn(p,n)124Sb, and Au(p,n)197m,gHg. The carrier-free activity was separated from the foils by novel separation schemes based on ion exchange and extraction chromatography techniques. Carrier-free Pb and Bi isotopes were obtained from development of a novel generator based on cation exchange chromatography using the 232U parent to generate 212Pb and 212Bi. Crown ethers show high selectivity for metal ions based on their size compared to the negatively charged cavity of the ether. Extraction by crown ethers occur based on electrostatic ion-dipole interactions between the negatively charged ring atoms (oxygen, sulfur, etc.) and the positively charged metal cations. Extraction chromatography resins produced by Eichrom Technologies, specifically the Pb resin based on di-t-byutlcyclohexano-18-crown-6, were chosen as a starting point for these studies. Simple chemical systems based solely on HCl matrices were explored to determine the extent of extraction for Pb, Sn and Hg on the resin. The kinetics and mechanism of extraction were also explored to determine suitability for a Fl chemical experiment. Systems based on KI/HCl and KI/HNO3 were explored for Bi and Sb. In both cases suitable separations, with high separation factors, were performed with vacuum flow columns containing the Pb-resin. Unfortunately the kinetics of uptake for Hg are far too slow on the traditional crown-ether to perform a Fl experiment and obtain whether or not Fl has true Hg-like character or not. However, the kinetics of Pb and Sn are more than sufficient for a Fl experiment to differentiate between Pb- or Sn-like character. To assess this kinetic issue a novel macrocyclic extractant based on sulfur donors was synthesized. Hexathia-18-crown-6, the sulfur analog of 18-crown-6, was synthesized based with by a template reaction using high dilution techniques. The replacement of oxygen ring atoms with sulfur should give the extractant a softer character, which should allow for far greater affinity toward soft metals such as Hg and Pb. From HCl matrices hexathia-18-crown-6 showed far greater kinetics and affinity for Hg than the Pb-resin; however, no affinity for Pb or Sn was seen. This presumably is due to the fact the charge density of sulfur crown ethers does not point to the center of the ring, and future synthesis of a substituted sulfur crown ether which forces the charge density to mimic that of the traditional crown ether should enable extraction of Pb and Sn to a greater extent than with the Pb-resin. Initial studies show promise for the separation of Bi and Sb from HCl matrices using hexathia-18-crown-6. Other macrocyclic extractants, including 2,2,2-cryptand, calix[6]arene and tetrathia-12-crown-4, were also investigated for comparison to the crown ethers. It was noted that these extractants are inferior compared to the crown and thiacrown ethers for extraction of Fl and element 115 homologs. A potential chemical system for Fl was established based on the Eichrom Pb resin, and insight to an improved system based on thiacrown ethers is presented.

  19. "Leaching or not leaching": an alternative approach to antimicrobial materials via copolymers containing crown ethers as active groups.

    PubMed

    De Rosa, M; Vigliotta, G; Soriente, A; Capaccio, V; Gorrasi, G; Adami, R; Reverchon, E; Mella, M; Izzo, L

    2017-03-28

    In this work, new copolymers containing either MMA and 18C6 crown-ether pendants, or PEG, MMA and 18C6 crown-ether pendants were synthesized to test the idea that sequestering structural alkali-earth ions from the bacterial outer membrane (OM) may lead to bacterial death. The copolymers were obtained either via uncontrolled radical polymerization or ATRP; the latter approached allowed us to produce not only linear copolymers but also branched Y-like structures. After checking for the capability of complexing magnesium and calcium ions, the antimicrobial activity of all copolymers was tested placing their casted plaques in contact with pure water E. coli suspensions. All plaques adsorbed alkali-earth ions and killed bacteria, albeit with different antimicrobial efficiencies. Differences in the latter characteristic were attributed to different plaque roughness. The role of the 18C6 crown-ether pendants was elucidated by pre-saturating plaques with Mg/Ca ions, the marked reduction in antimicrobial efficiency indicating that losing the latter from OM due to surface complexation does play an important role in killing bacteria at short (<5 h) contact times. At longer times, the mode of action is instead related to the poly-cationic nature acquired by the plaques due to ion sequestering.

  20. Separation of Long-Lived Fission Products Tc-99 and I-129 from Synthetic Effluents by Crown Ethers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paviet-Hartmann, P.; Hartmann, T.

    2006-07-01

    To minimize significantly the radio-toxic inventory of nuclear geological repositories to come as well as to reduce the potential of radionuclides migration and to minimize long-term exposure, the concept of partitioning and transmutation (P/T) of nuclear waste is currently discussed. Transmutation offers the possibility to convert radio-toxic radionuclides with long half-lives into radionuclides of shorter half-lives, less toxic isotopes, or even into stable isotopes. Besides the most prominent isotopes of neptunium, plutonium, americium, and curium, the long-lived fission products Tc-99 and I-129 (half-lives of 2.13 x 10{sup 5} years, and 1.57 x 10{sup 7} years, respectively) are promising candidates formore » transmutation in order to prevent their migration from a nuclear repository. Partitioning and transmutation of the most radio-toxic radionuclides will not only minimize the nuclear waste load but most importantly will significantly reduce the long-term radio-toxic hazard of nuclear waste repositories to come. Prior to the deployment of partitioning and transmutation, selective extraction techniques are required to separate the radionuclides of concern. Since the discovery of crown ethers by C. Pedersen, various applications of crown ethers have drawn much attention. Although liquid-liquid extraction of alkali and alkali earth metals by crown ethers has been extensively studied, little data is available on the extraction of Tc-99 and I-129 by crown ethers. The methods developed herein for the specific extraction of Tc-99 and I-129 provide recommendations in support of their selectively extraction from liquid radioactive waste streams, mainly ILW. We report data on the solvent extraction of Tc-99 and I-129 from synthetic effluents by six crown ethers of varying cavity dimensions and derivatization. To satisfy the needs of new extractant systems we are demonstrating that crown ether (CE) based systems have the potential to serve as selective extractants for the separation of these long lived radionuclides from high level nuclear waste (HLW), intermediate level nuclear waste (ILW), and low level nuclear waste (LLW) streams. The experimental results show that dibenzo-18-crown-6 (DB 18C6) is highly selective towards Tc-99, and dicyclohexano-18-crown-6 (DC18C6) is highly selective towards I-129. The nature of the diluent was examined and was shown to be the most influential variable in controlling the extraction coefficients of Tc-99 and I-129. Therefore the addition of polar diluent acetone to non-polar diluent toluene enhanced the distribution coefficient of Tc-99 (DTc) was by a factor of 30. For I-129, the best extraction yield was obtained after introducing tetrachloroethane. Through the process, by a single extraction step, 85 % to 95 % of Tc-99 was extracted from synthetic effluents, while 84 % to 88 % of I-129 was extracted from different acidic media. The extraction by crown ether is a fairly rapid process and the total preparation time of the chemical separation takes about 20 minutes for a batch of eight samples. (authors)« less

  1. Synthesis and pKa determination of new enantiopure dimethyl-substituted acridino-crown ethers containing a carboxyl group: Useful candidates for enantiomeric recognition studies.

    PubMed

    Németh, Tamás; Dargó, Gergő; Petró, József Levente; Petrik, Zsófia; Lévai, Sándor; Krámos, Balázs; Béni, Zoltán; Nagy, József; Balogh, György Tibor; Huszthy, Péter; Tóth, Tünde

    2017-09-01

    New enantiopure dimethyl-substituted acridino-18-crown-6 and acridino-21-crown-7 ethers containing a carboxyl group at position 9 of the acridine ring [(S,S)-8, (S,S)-9, (R,R)-10] were synthesized. The pK a values of the new crown ethers [(S,S)-8, (S,S)-9, (R,R)-10] and of an earlier reported macrocycle [(R,R)-2] were determined by UV-pH titrations. Crown ether (S,S)-8 was attached to silica gel by covalent bonds and the enantiomeric separation ability of the newly prepared chiral stationary phase [(S,S)-CSP-12] was studied by high-performance liquid chromatography (HPLC). Homochiral preference was observed and the best separation was achieved for the enantiomers of 1-NEA. Ligands (S,S)-9 and (R,R)-10 are precursors of enantioselective sensor and selector molecules for the enantiomers of protonated primary amines, amino acids, and their derivatives. © 2017 Wiley Periodicals, Inc.

  2. Isolation of (CO)1- and (CO2)1- radical complexes of rare earths via Ln(NR2)3/K reduction and [K2(18-crown-6)2]2+ oligomerization.

    PubMed

    Fang, Ming; Farnaby, Joy H; Ziller, Joseph W; Bates, Jefferson E; Furche, Filipp; Evans, William J

    2012-04-11

    Deep-blue solutions of Y(2+) formed from Y(NR(2))(3) (R = SiMe(3)) and excess potassium in the presence of 18-crown-6 at -45 °C under vacuum in diethyl ether react with CO at -78 °C to form colorless crystals of the (CO)(1-) radical complex, {[(R(2)N)(3)Y(μ-CO)(2)][K(2)(18-crown-6)(2)]}(n), 1. The polymeric structure contains trigonal bipyramidal [(R(2)N)(3)Y(μ-CO)(2)](2-) units with axial (CO)(1-) ligands linked by [K(2)(18-crown-6)(2)](2+) dications. Byproducts such as the ynediolate, [(R(2)N)(3)Y](2)(μ-OC≡CO){[K(18-crown-6)](2)(18-crown-6)}, 2, in which two (CO)(1-) anions are coupled to form (OC≡CO)(2-), and the insertion/rearrangement product, {(R(2)N)(2)Y[OC(═CH(2))Si(Me(2))NSiMe(3)]}[K(18-crown-6)], 3, are common in these reactions that give variable results depending on the specific reaction conditions. The CO reduction in the presence of THF forms a solvated variant of 2, the ynediolate [(R(2)N)(3)Y](2)(μ-OC≡CO)[K(18-crown-6)(THF)(2)](2), 2a. CO(2) reacts analogously with Y(2+) to form the (CO(2))(1-) radical complex, {[(R(2)N)(3)Y(μ-CO(2))(2)][K(2)(18-crown-6)(2)]}(n), 4, that has a structure similar to that of 1. Analogous (CO)(1-) and (OC≡CO)(2-) complexes of lutetium were isolated using Lu(NR(2))(3)/K/18-crown-6: {[(R(2)N)(3)Lu(μ-CO)(2)][K(2)(18-crown-6)(2)]}(n), 5, [(R(2)N)(3)Lu](2)(μ-OC≡CO){[K(18-crown-6)](2)(18-crown-6)}, 6, and [(R(2)N)(3)Lu](2)(μ-OC≡CO)[K(18-crown-6)(Et(2)O)(2)](2), 6a. © 2012 American Chemical Society

  3. Temperature-dependent IR spectroscopic and structural study of 18-crown-6 chelating ligand in the complexation with sodium surfactant salts and potassium picrate.

    PubMed

    Mihelj, Tea; Tomašić, Vlasta; Biliškov, Nikola; Liu, Feng

    2014-04-24

    18-crown-6 ether (18C6) complexes with the following anionic surfactants: sodium n-dodecylsulfate (18C6-NaDS), sodium 4-(1-pentylheptyl)benzenesulfonate (18C6-NaDBS); and potassium picrate (18C6-KP) were synthesized and studied in terms of their thermal and structural properties. Physico-chemical properties of new solid 1:1 coordination complexes were characterized by infrared (IR) spectroscopy, thermogravimetry and differential thermal analysis, differential scanning calorimetry, X-ray diffraction and microscopic observations. The strength of coordination between Na(+) and oxygen atoms of 18C6 ligand does not depend on anionic part of the surfactant, as established by thermodynamical parameters obtained by temperature-dependent IR spectroscopy. Each of these complexes exhibit different kinds of endothermic transitions in heating scan. Diffraction maxima obtained by SAXS and WAXS, refer the behavior of the compounds 18C6-NaDS and 18C6-NaDBS as smectic liquid crystalline. Distortion of 18C6-NaDS and 18C6-KP complexes occurs in two steps. Temperature of the decomplexation of solid crystal complex 18C6-KP is considerably higher than of mesophase complexes, 18C6-NaDS, and 18C6-NaDBS. The structural and liquid crystalline properties of novel 18-crown-ether complexes are function of anionic molecule geometry, type of chosen cation (Na(+), K(+)), as well as architecture of self-organized aggregates. A good combination of crown ether unit and amphiphile may provide a possibility for preparing new functionalized materials, opening the research field of ion complexation and of host-guest type behavior. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Guanidinium/ammonium competition and proton transfer in the interaction of the amino acid arginine with the tetracarboxylic 18-crown-6 ionophore.

    PubMed

    Avilés-Moreno, Juan Ramón; Berden, Giel; Oomens, Jos; Martínez-Haya, Bruno

    2018-02-07

    The recognition of arginine plays a central role in modern proteomics and genomics. Arginine is unique among natural amino acids due to the high basicity of its guanidinium side chain, which sustains specific interactions and proton exchange biochemical processes. The search for suitable macrocyclic ionophores constitutes a promising route towards the development of arginine receptors. This study evaluates the conformational features involved in the binding of free arginine by the polyether macrocycle (18-crown-6)-tetracarboxylic acid. Infrared action vibrational spectroscopy and quantum-chemical computations are combined to characterize the complexes with net charges +1 and +2. The spectrum of the +1 complex can be explained in terms of a configuration predominantly stabilized by a robust bidentate coordination of guanidinium with a carboxylate group formed from the deprotonation of one side group of the crown ether. The released proton is transferred to the amino terminus of arginine, which then coordinates with the crown ether ring. In an alternative type of conformation, partly consistent with experiment, the amino terminus is neutral and the guanidinium group inserts into the crown ether cavity. In the +2 complexes, arginine is always doubly protonated and the most stable conformations are characterized by a tripodal coordination of the ammonium -NH 3 + group of arginine with the oxygen atoms of the macrocycle ring, while the interactions of the amino acid with the side carboxylic acid groups of the crown ether acquire a remarkable lesser role.

  5. 4-Fluoro­anilinium tetra­chloridoferrate(III) 18-crown-6 clathrate

    PubMed Central

    Ge, Jia-Zhen; Zhao, Min-Min

    2010-01-01

    The reaction of 4-fluoro­aniline hydro­chloride, 18-crown-6 and ferric chloride in methano­lic solution yields the title compound, (C6H7FN)[FeCl4]·C12H24O6, which has an unusual supramolecular structure. N—H⋯O hydrogen-bonding inter­actions between the NH3 + substituents of the 4-fluoro­anilinium cations and the O atoms of the crown ether mol­ecules result in a rotator–stator-like structure. PMID:21587679

  6. Design, synthesis, characterization, and OFET properties of amphiphilic heteroleptic tris(phthalocyaninato) europium(III) complexes. The effect of crown ether hydrophilic substituents.

    PubMed

    Gao, Yingning; Ma, Pan; Chen, Yanli; Zhang, Ying; Bian, Yongzhong; Li, Xiyou; Jiang, Jianzhuang; Ma, Changqin

    2009-01-05

    Two amphiphilic heteroleptic tris(phthalocyaninato) europium complexes with hydrophilic crown ether heads and hydrophobic octyloxy tails [Pc(mCn)(4)]Eu[Pc(mCn)(4)]Eu[Pc(OC(8)H(17))(8)] [m = 12, n = 4, H(2)Pc(12C4)(4) = 2,3,9,10,16,17,23,24-tetrakis(12-crown-4)phthalocyanine; m = 18, n = 6, H(2)Pc(18C6)(4) = 2,3,9,10,16,17,23,24-tetrakis(18-crown-6)phthalocyanine; H(2)Pc(OC(8)H(17))(8) = 2,3,9,10,16,17,23,24-octakis(octyloxy)phthalocyanine] (1, 2) were designed and prepared from the reaction between homoleptic bis(phthalocyaninato) europium compound [Pc(mCn)(4)]Eu[Pc(mCn)(4)] (m = 12, n = 4; m = 18, n = 6) and metal-free H(2)Pc(OC(8)H(17))(8) in the presence of Eu(acac)(3).H(2)O (Hacac = acetylacetone) in boiling 1,2,4-trichlorobenzene. These novel sandwich triple-decker complexes were characterized by a wide range of spectroscopic methods and electrochemically studied. With the help of the Langmuir-Blodgett technique, these typical amphiphilic triple-decker complexes were fabricated into organic field effect transistors (OFET) with top contact configuration on bare SiO(2)/Si substrate, hexamethyldisilazane-treated SiO(2)/Si substrate, and octadecyltrichlorosilane (OTS)-treated SiO(2)/Si substrate, respectively. The device performance is revealed to be dependent on the species of crown ether substituents and substrate surface treatment. OFETs fabricated from the triple decker with 12-crown-4 hydrophilic substituents, 1, allow the hole transfer in the direction parallel to the aromatic phthalocyanine rings. In contrast, the devices of a triple-decker compound containing 18-crown-6 as hydrophilic heads, 2, transfer holes in a direction along the long axis of the assembly composed of face-to-face aggregated triple-decker molecules, revealing the effect of molecular structure, specifically the crown ether substituents on the film structure and OFET functional properties. The carrier mobility for hole as high as 0.33 cm(2) V(-1) s(-1) and current modulation of 7.91 x 10(5) were reached for the devices of triple-decker compound 1 deposited on the OTS-treated SiO(2)/Si substrates, indicating the effect of substrate surface treatment on the OFET performance due to the improvement on the film quality as demonstrated by the atomic force microscope investigation results.

  7. Crown ethers in graphene

    DOE PAGES

    Guo, Junjie; Lee, Jaekwang; Contescu, Cristian I.; ...

    2014-11-13

    Crown ethers, introduced by Pedersen1, are at their most basic level neutral rings constructed of oxygen atoms linked by two- or three-carbon chains. They have attracted special attention for their ability to selectively incorporate various atoms2 or molecules within the cavity formed by the ring3-6. This property has led to the use of crown ethers and their compounds in a wide range of chemical and biological applications7,8. However, crown ethers are typically highly flexible, frustrating efforts to rigidify them for many uses that demand higher binding affinity and selectivity9,10. In this Letter, we report atomic-resolution images of the same basicmore » structures of the original crown ethers embedded in graphene. This arrangement constrains the crown ethers to be rigid and planar and thus uniquely suited for the many applications that crown ethers are known for. First-principles calculations show that the close similarity of the structures seen in graphene with those of crown ether molecules also extends to their selectivity towards specific metal cations depending on the ring size. Atoms (or molecules) incorporated within the crown ethers in graphene offer a simple environment that can be easily and systematically probed and modeled. Thus, we expect that this discovery will introduce a new wave of investigations and applications of chemically functionalized graphene.« less

  8. Influence of the composition of aqueous dimethylsulfoxide solvent on thermodynamics of complexing between 18-crown-6-ether and D,L-alanine

    NASA Astrophysics Data System (ADS)

    Usacheva, T. R.; Kuzmina, I. A.; Sharnin, V. A.; Chernov, I. V.; Matteoli, E.

    2012-07-01

    Standard thermodynamic parameters (log K o, Δr H o, TΔr S o) of complexing 18-crown-6 ether (18C6) with D,L-alanine (Ala) in mixed water-dimethysulfoxide (H2O-DMSO) solvents are calculated on the basis of calorimetric titration results. A rise in the DMSO concentration in mixed solvent is found to increase stability and increase the exothermicity of the formation of [Ala-18C6] molecular complex. Changes in the reaction energetic are shown to be determined by changes in the solvation state of 18C6 that is the characteristic of the reactions of molecular complex formation between 18C6 and D,L-alanine or glycine in water-organic solvents.

  9. The influence of water-ethanol mixture on the thermodynamics of complex formation between 18-crown-6 ether and L-phenylalanine

    NASA Astrophysics Data System (ADS)

    Usacheva, T. R.; Sharnin, V. A.; Chernov, I. V.; Matteoli, E.; Terekhova, I. V.; Kumeev, R. S.

    2012-08-01

    The influence of water-ethanol mixture composition on the complex formation between 18-crown-6 ether and L-phenylalanine was studied by titration calorimetry at Т = 298.15 K. The standard thermodynamic parameters (ΔrGо, ΔrHо, ТΔrSо) of formation of [Phe18C6] molecular complex were calculated from data obtained by means of the microcalorimetric system TAM III (TA Instruments, USA) at X(EtOH) = 0.0/0.6 mol fraction. The stability of [Phe18C6] and the mechanism of complexation in water were investigated using the 1Н and 13С NMR spectroscopy. The increase of EtOH concentration results in an increase of the complex stability and of the exothermicity of complexation.

  10. Proton Conduction in Tröger's Base Linked Poly(crown ether)s.

    PubMed

    Patel, Hasmukh A; Selberg, John; Salah, Dhafer; Chen, Haoyuan; Liao, Yijun; Nalluri, Siva Krishna Mohan; Farha, Omar K; Snurr, Randall Q; Rolandi, Marco; Stoddart, J Fraser

    2018-06-05

    Exactly 50 years ago, the ground-breaking discovery of dibenzo[18]crown-6 (DB18C6) by Charles Pedersen, led to the use of DB18C6 as a receptor in supramolecular chemistry and a host in host‒guest chemistry. We have demonstrated proton conductivity in Tröger's base-linked polymers through hydrogen-bonded networks formed from adsorbed water molecules on the oxygen atoms of DB18C6 under humid conditions. Tröger's base-linked polymers - poly(TBL‒DB18C6)-t and poly(TBL‒DB18C6)-c - synthesized by the in situ alkylation and cyclization of either trans- or cis-di(aminobenzo) [18]crown-6 at room temperature have been isolated as high molecular weight polymers. The macromolecular structures of the isomeric poly(TBL‒DB18C6)s have been established by spectroscopic techniques and size-exclusion chromatography. The excellent solubility of these polymers in chloroform allows the formation of free-standing membranes which are thermally stable and also show stability under aqueous conditions. The hydrophilic nature of the DB18C6 building blocks in the polymer facilitates retention of the water as confirmed by water-vapor adsorption isotherms which show a 23 wt% water uptake. The adsorbed water is retained even after reducing the relative humidity to 25 %. The proton conductivity of poly(TBL‒DB18C6)-t which is found to be 1.4 x 10‒4 mS cm‒1 in a humid environment, arises from the hydrogen bonding and the associated proton hopping mechanism, as supported by a modeling study. In addition to proton conductivity, the Tröger's base-linked polymers reported here promise a wide range of applications where the sub-nanometer-sized cavities of the crown ethers and the robust film-forming ability are the governing factors in dictating their properties.

  11. A study on 2, 4, 6-trinitrotolurene (TNT) vapor detection by using a quartz crystal microbalance with 18-crown-6 ether film

    NASA Astrophysics Data System (ADS)

    Phetchakul, Toempong; Phuvanatai, Pavaris

    2017-07-01

    The application of 18-crown-6 ether film for 2, 4, 6-trinitrotolurene (TNT) vapor detection by using quartz crystal microbalance (QCM) is studied. The film is coated on the quartz electrodes as sensitive material for capture TNT molecule. The parameters that are studied are concentration and mass or thickness of film. When the explosive adheres to surface of the crystal oscillator, the weight is changed and the resonance frequency of the crystal oscillator is shifted lower. The frequency shift (Δf) relates to concentration and mass or thickness. The high concentration and mass/thickness of film enhance the TNT detection.

  12. The inverse sandwich complex [(K(18-crown-6))2Cp][CpFe(CO)2]--unpredictable redox reactions of [CpFe(CO)2]I with the silanides Na[SiRtBu2] (R = Me, tBu) and the isoelectronic phosphanyl borohydride K[PtBu2BH3].

    PubMed

    Sänger, Inge; Kückmann, Theresa I; Dornhaus, Franz; Bolte, Michael; Wagner, Matthias; Lerner, Hans-Wolfram

    2012-06-14

    The dimeric iron carbonyl [CpFe(CO)(2)](2) and the iodosilanes tBu(2)RSiI were obtained from the reaction of [CpFe(CO)(2)]I with the silanides Na[SiRtBu(2)] (R = Me, tBu) in THF. By the reactions of [CpFe(CO)(2)]I and Na[SiRtBu(2)] (R = Me, tBu) the disilanes tBu(2)RSiSiRtBu(2) (R = Me, tBu) were additionally formed using more than one equivalent of the silanide. In this context it should be noted that reduction of [CpFe(CO)(2)](2) with Na[SitBu(3)] gives the disilanes tBu(3)SiSitBu(3) along with the sodium ferrate [(Na(18-crown-6))(2)Cp][CpFe(CO)(2)]. The potassium analogue [(K(18-crown-6))(2)Cp][CpFe(CO)(2)] (orthorhombic, space group Pmc2(1)), however, could be isolated as a minor product from the reaction of [CpFe(CO)(2)]I with [K(18-crown-6)][PtBu(2)BH(3)]. The reaction of [CpFe(CO)(2)](2) with the potassium benzophenone ketyl radical and subsequent treatment with 18-crown-6 yielded the ferrate [K(18-crown-6)][CpFe(CO)(2)] in THF at room temperature. The crown ether complex [K(18-crown-6)][CpFe(CO)(2)] was analyzed using X-ray crystallography (orthorhombic, space group Pna2(1)) and its thermal behaviour was investigated.

  13. Coordination effect-regulated CO2 capture with an alkali metal onium salts/crown ether system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Zhen-Zhen; Jiang, Deen; Zhu, Xiang

    2014-01-01

    A coordination effect was employed to realize equimolar CO2 absorption, adopting easily synthesized amino group containing absorbents (alkali metal onium salts). The essence of our strategy was to increase the steric hindrance of cations so as to enhance a carbamic acid pathway for CO2 capture. Our easily synthesized alkali metal amino acid salts or phenolates were coordinated with crown ethers, in which highly sterically hindered cations were obtained through a strong coordination effect of crown ethers with alkali metal cations. For example, a CO2 capacity of 0.99 was attained by potassium prolinate/18-crown-6, being characterized by NMR, FT-IR, and quantum chemistrymore » calculations to go through a carbamic acid formation pathway. The captured CO2 can be stripped under very mild conditions (50 degrees C, N-2). Thus, this protocol offers an alternative for the development of technological innovation towards efficient and low energy processes for carbon capture and sequestration.« less

  14. μ-Hexa-thio-metadiphosphato-bis-[(1,4,7,10,13,16-hexa-oxa-cyclo-octa-decane-κ(6) O)rubidium] aceto-nitrile disolvate.

    PubMed

    Gjikaj, Mimoza; Pook, Niels-Patrick; Qarri, Flora

    2013-12-01

    The asymmetric unit of the title compound, [Rb2(P2S6)(C12H24O6)2]·2CH3CN, contains one half of an [Rb(18-crown-6)2]2[P2S6] unit and one aceto-nitrile solvent mol-ecule. The [Rb(18-crown-6)]2[P2S6] unit is completed by inversion symmetry. Its Rb(+) ion is situated near the centre of the macrocyclic cavity, but is displaced by 0.8972 (1) Å from the O atoms of the crown in the direction of the [P2S6](2-) moiety. The overall coordination number of the cation is eight, defined by the six crown ether O atoms and by two terminal S atoms of the [P2S6](2-) anion. The hexa-thio-metadiphosphate anion is built up from two tetra-hedral PS4 units joined together by a common edge. The crystal structure is characterized by alternating layers of [Rb(18-crown-6)]2[P2S6] and aceto-nitrile solvent mol-ecules stacked along [010].

  15. Crystal structures of complexes of the cys-syn-cys isomer of dicyclohexano-18-crown-6 with oxonium hexafluorotantalate and oxonium hexafluoroniobate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fonari, M. S.; Alekseeva, O. A.; Furmanova, N. G.

    2007-03-15

    The crystal structures of [(cys-syn-cys-dicyclohexano-18-crown-6 . H{sub 3}O)][TaF{sub 6}] and [(cys-syn-cys-dicyclohexano-18-crown-6 . H{sub 3}O)][NbF{sub 6}] complex compounds are determined using X-ray diffraction analysis. The tantalum complex has two polymorphic modifications, namely, the monoclinic (I) and triclinic (II) modifications. The unit cell parameters of these compounds are as follows: a = 8.507(4) A, b = 11.947(5) A, c = 27.392(12) A, {beta} = 93.11(1) deg., Z = 4, and space group P2{sub 1}/n for modification I; and a = 10.828(1) A, b = 11.204(1) A, c = 12.378(1) A, {alpha} = 72.12(1) deg., {beta} = 79.40(1) deg., {gamma} = 73.70(1) deg.,more » Z = 2, and space group P-1 for modification II. The triclinic niobium complex [(cys-syn-cys-dicyclohexano-18-crown-6 . H{sub 3}O)][NbF{sub 6}] (III) with the unit cell parameters a = 10.796(3) A, b = 11.183(3) A, c = 12.352(3) A, {alpha} = 72.364(5) deg., {beta} = 79.577(5) deg., {gamma} = 73.773(4) deg., Z = 2, and space group P-1 is isostructural with tantalum complex II. The structures of all three complexes are ionic in character. The oxonium cation in complexes I-III is encapsulated by the crown ether and thus forms one ordinary and two bifurcated hydrogen bonds with the oxygen atoms of the crown ether. This macrocyclic cation is bound to the anions through the C-H...F contacts (H...F, 2.48-2.58 A). The conformation of the macrocycle in complex I differs substantially from that in complex II (III)« less

  16. Vibrational Signatures of Large Amplitude Motions for the Shackled Hydronium Ion Nested in 18-CROWN-6 Ether Using D2 Tagging

    NASA Astrophysics Data System (ADS)

    Duong, Chinh H.; Menges, Fabian; Craig, Stephanie; Wolke, Conrad T.; Johnson, Mark

    2016-06-01

    The diffuse spectra arising from the excess proton in dilute acids suggests that its behavior is highly dependent on the local environment surrounding it. In this work, we report how the spectra of the H3O+, NH4+, and CH3NH3+ ions respond when docked to the rigid, tri-coordinated binding pocket of the 18-crown-6 ether using cryogenic ion vibrational predissociation (CIVP) spectroscopy with D2 tagging at 10 K. The H3O+{tiny^bullet}18-crown-6 ether complex displays a broad (350 cm-1 FWHM) unstructured band arising from the OH stretching fundamentals, which is significantly broader than the corresponding band (125 cm-1 FWHM) in the Eigen cation (H9O4+) spectrum. Perdeuterated isotopologue studies for both systems yield sharper bands with clear multiplet structures, indicating that the broadening arises from nuclear quantum effects. The key displacements underlying this coupling were explored using the vibrationally adiabatic scheme introduced by McCoy in the context of similar broadening in the Ca2+OH-(H2O)n system. Christopher J. Johnson, Laura C. Dzugan, Arron B. Wolk, Christopher M. Leavitt, Joseph A. Fournier, Anne B. McCoy, Mark A. Johnson, J. Phys. Chem. A 118, 2014.

  17. Alkaline earth cation extraction from acid solution

    DOEpatents

    Dietz, Mark; Horwitz, E. Philip

    2003-01-01

    An extractant medium for extracting alkaline earth cations from an aqueous acidic sample solution is described as are a method and apparatus for using the same. The separation medium is free of diluent, free-flowing and particulate, and comprises a Crown ether that is a 4,4'(5')[C.sub.4 -C.sub.8 -alkylcyclohexano]18-Crown-6 dispersed on an inert substrate material.

  18. Radionuclide-binding compound, a radionuclide delivery system, a method of making a radium complexing compound, a method of extracting a radionuclide, and a method of delivering a radionuclide

    DOEpatents

    Fisher, Darrell R.; Wai, Chien M.; Chen, Xiaoyuan

    2000-01-01

    The invention pertains to compounds which specifically bind radionuclides, and to methods of making radionuclide complexing compounds. In one aspect, the invention includes a radionuclide delivery system comprising: a) a calix[n]arene-crown-[m]-ether compound, wherein n is an integer greater than 3, and wherein m is an integer greater than 3, the calix[n]arene-crown-[m]-ether compound comprising at least two ionizable groups; and b) an antibody attached to the calix[n]arene-crown-[m]-ether compound. In another aspect, the invention includes a method of making a radium complexing compound, comprising: a) providing a calix[n]arene compound, wherein n is an integer greater than 3, the calix[n]arene compound comprising n phenolic hydroxyl groups; b) providing a crown ether precursor, the crown ether precursor comprising a pair of tosylated ends; c) reacting the pair of tosylated ends with a pair of the phenolic hydroxyl groups to convert said pair of phenolic hydroxyl groups to ether linkages, the ether linkages connecting the crown ether precursor to the calix[n]arene to form a calix[n]arene-crown-[m]-ether compound, wherein m is an integer greater than 3; d) converting remaining phenolic hydroxyl groups to esters; e) converting the esters to acids, the acids being proximate a crown-[m]-ether portion of the calix[n]arene-crown-[m]-ether compound; and f) providing a Ra.sup.2+ ion within the crown-[m]-ether portion of the calix[n]arene-crown-[m]-ether compound.

  19. Trivalent scandium, yttrium and lanthanide complexes with thia-oxa and selena-oxa macrocycles and crown ether coordination.

    PubMed

    Champion, Martin J D; Farina, Paolo; Levason, William; Reid, Gillian

    2013-09-28

    Complexes of the oxa-thia macrocycles [18]aneO4S2, [15]aneO3S2 and the oxa-selena macrocycle [18]aneO4Se2 (L) of types [MCl2(L)]FeCl4 (M = Sc or Y) were prepared from [ScCl3(thf)3] or [YCl2(THF)5][YCl4(THF)2] and the ligand in anhydrous MeCN, using FeCl3 as a chloride abstractor. The [MI2(L)]I, [LaI3(L)] and [LuI2(L)]I have been prepared from the ligands and the appropriate anhydrous metal triiodide in MeCN. Complexes of type [LaI3(crown)] and [LuI2(crown)]I (crown = 18-crown-6, 15-crown-5) were made for comparison. Use of the metal iodide results in complexes with high solubility compared to the corresponding chlorides, although also with increased sensitivity to moisture. All complexes were characterised by microanalysis, IR, (1)H, (45)Sc and (77)Se NMR spectroscopy as appropriate. X-ray crystal structures are reported for [ScCl2([18]aneO4S2)][FeCl4], [ScI2([18]aneO4S2)]I, [YCl2(18-crown-6)]3[Y2Cl9], [YCl2([18]aneO4S2)][FeCl4], [LaI3(15-crown-5)], [LaI2(18-crown-6)(MeCN)]I, [LuI(18-crown-6)(MeCN)2]I2, [Lu(15-crown-5)(MeCN)2(OH2)]I3, [LaI3([18]aneO4S2)], [LaI([18]aneO4S2)(OH2)]I2, [LaI3([18]aneO4Se2)] and [LuI2([18]aneO4Se2)]I. In each complex all the neutral donor atoms of the macrocycles are coordinated to the metal centre, showing very rare examples of these oxophilic metal centres coordinated to thioether groups, and the first examples of coordinated selenoether donors. In some cases MeCN or adventitious water displaces halide ligands, but not the S/Se donors from La or Lu complexes. A complex of the oxa-tellura macrocycle [18]aneO4Te2, [ScCl2([18]aneO4Te2)][FeCl4] was isolated, but is unstable in MeCN solution, depositing elemental Te. YCl3 and 18-crown-6 produced [YCl2(18-crown-6)]3[Y2Cl9], the asymmetric unit of which contains two cations with a trans-YCl2 arrangement and a third with a cis-YCl2 group.

  20. μ-Hexa­thio­metadiphosphato-bis­[(1,4,7,10,13,16-hexa­oxa­cyclo­octa­decane-κ6 O)rubidium] aceto­nitrile disolvate

    PubMed Central

    Gjikaj, Mimoza; Pook, Niels-Patrick; Qarri, Flora

    2013-01-01

    The asymmetric unit of the title compound, [Rb2(P2S6)(C12H24O6)2]·2CH3CN, contains one half of an [Rb(18-crown-6)2]2[P2S6] unit and one aceto­nitrile solvent mol­ecule. The [Rb(18-crown-6)]2[P2S6] unit is completed by inversion symmetry. Its Rb+ ion is situated near the centre of the macrocyclic cavity, but is displaced by 0.8972 (1) Å from the O atoms of the crown in the direction of the [P2S6]2− moiety. The overall coordination number of the cation is eight, defined by the six crown ether O atoms and by two terminal S atoms of the [P2S6]2− anion. The hexa­thio­metadiphosphate anion is built up from two tetra­hedral PS4 units joined together by a common edge. The crystal structure is characterized by alternating layers of [Rb(18-crown-6)]2[P2S6] and aceto­nitrile solvent mol­ecules stacked along [010]. PMID:24860286

  1. Hydrogen bonding assemblies in host guest complexes with 18-crown-6

    NASA Astrophysics Data System (ADS)

    Fonari, M. S.; Simonov, Yu. A.; Kravtsov, V. Ch.; Lipkowski, J.; Ganin, E. V.; Yavolovskii, A. A.

    2003-02-01

    Recent X-ray crystal structural data for two novel 1:2 host-guest complexes of 18-crown-6 with neutral organic molecules, thiaamide hydrazide of 2-aminobenzoic acid and thiaamide hydrazide of 4-amino-1,2,5-thiadiazole-3-carbonic acid are reported. The supramolecular structures of these two and five relative complexes are discussed from the point of view of participation of donor groups in coordination with the crown ether, and donor and acceptor groups in the self-assembly of the guest molecules. Guest molecules have incorporated amine and hydrazine moieties as proton donors and carbonyl oxygen and sulfur (in thiadiazole and in thiaamine moieties) as proton acceptors. The guest-guest interactions appeared to be crucial in the final architecture.

  2. Extractant composition including crown ether and calixarene extractants

    DOEpatents

    Meikrantz, David H.; Todd, Terry A.; Riddle, Catherine L.; Law, Jack D.; Peterman, Dean R.; Mincher, Bruce J.; McGrath, Christopher A.; Baker, John D.

    2009-04-28

    An extractant composition comprising a mixed extractant solvent consisting of calix[4] arene-bis-(tert-octylbenzo)-crown-6 ("BOBCalixC6"), 4',4',(5')-di-(t-butyldicyclo-hexano)-18-crown-6 ("DtBu18C6"), and at least one modifier dissolved in a diluent. The DtBu18C6 may be present at from approximately 0.01M to approximately 0.4M, such as at from approximately 0.086 M to approximately 0.108 M. The modifier may be 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol ("Cs-7SB") and may be present at from approximately 0.01M to approximately 0.8M. In one embodiment, the mixed extractant solvent includes approximately 0.15M DtBu18C6, approximately 0.007M BOBCalixC6, and approximately 0.75M Cs-7SB modifier dissolved in an isoparaffinic hydrocarbon diluent. The extractant composition further comprises an aqueous phase. The mixed extractant solvent may be used to remove cesium and strontium from the aqueous phase.

  3. Composition and process for separating cesium ions from an acidic aqueous solution also containing other ions

    DOEpatents

    Dietz, Mark L.; Horwitz, E. Philip; Bartsch, Richard A.; Barrans, Jr., Richard E.; Rausch, David

    1999-01-01

    A crown ether cesium ion extractant is disclosed as is its synthesis. The crown ether cesium ion extractant is useful for the selective purification of cesium ions from aqueous acidic media, and more particularly useful for the isolation of radioactive cesium-137 from nuclear waste streams. Processes for isolating cesium ions from aqueous acidic media using the crown ether cesium extractant are disclosed as are processes for recycling the crown ether cesium extractant and processes for recovering cesium from a crown ether cesium extractant solution.

  4. Composition and process for separating cesium ions from an acidic aqueous solution also containing other ions

    DOEpatents

    Dietz, M.L.; Horwitz, E.P.; Bartsch, R.A.; Barrans, R.E. Jr.; Rausch, D.

    1999-03-30

    A crown ether cesium ion extractant is disclosed as is its synthesis. The crown ether cesium ion extractant is useful for the selective purification of cesium ions from aqueous acidic media, and more particularly useful for the isolation of radioactive cesium-137 from nuclear waste streams. Processes for isolating cesium ions from aqueous acidic media using the crown ether cesium extractant are disclosed as are processes for recycling the crown ether cesium extractant and processes for recovering cesium from a crown ether cesium extractant solution. 4 figs.

  5. Crown Ether Complexes of Alkali-Metal Chlorides from SO2.

    PubMed

    Reuter, Kirsten; Rudel, Stefan S; Buchner, Magnus R; Kraus, Florian; von Hänisch, Carsten

    2017-07-18

    The structures of alkali-metal chloride SO 2 solvates (Li-Cs) in conjunction with 12-crown-4 or 1,2-disila-12-crown-4 show strong discrepancies, despite the structural similarity of the ligands. Both types of crown ethers form 1:1 complexes with LiCl to give [Li(1,2-disila-12-crown-4)(SO 2 Cl)] (1) and [Li(12-crown-4)Cl]⋅4 SO 2 (2). However, 1,2-disila-12-crown-4 proved unable to coordinate cations too large for the cavity diameter, for example, by the formation of sandwich-type complexes. As a result, 12-crown-4 reacts exclusively with the heavier alkali-metal chlorides NaCl, KCl and RbCl. Compounds [Na(12-crown-4) 2 ]Cl⋅4 SO 2 (3) and [M(12-crown-4) 2 (SO 2 )]Cl⋅4 SO 2 (4: M=K; 5: M=Rb) all showed S-coordination to the chloride ions through four SO 2 molecules. Compounds 4 and 5 additionally exhibit the first crystallographically confirmed non-bridging O,O'-coordination mode of SO 2 . Unexpectedly, the disila-crown ether supports the dissolution of RbCl and CsCl in the solvent and gives the homoleptic SO 2 -solvated alkali-metal chlorides [MCl⋅3 SO 2 ] (6: M=Rb; 7: M=Cs), which incorporate bridging μ-O,O'-coordinating moieties and the unprecedented side-on O,O'-coordination mode. All compounds were characterised by single-crystal X-ray diffraction. The crown ether complexes were additionally studied by using NMR spectroscopy, and the presence of SO 2 at ambient temperature was revealed by IR spectroscopy of the neat compounds. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Structure and Bonding in Uranyl(VI) Peroxide and Crown Ether Complexes; Comparison of Quantum Chemical and Experimental Data.

    PubMed

    Vallet, Valérie; Grenthe, Ingmar

    2017-12-18

    The structure, chemical bonding, and thermodynamics of alkali ions in M[12-crown-4] + , M[15-crown-5] + , and M[18-crown-6] + , M[UO 2 (O 2 )(OH 2 ) 2 ] + 4,5 , and M[UO 2 (O 2 )(OH)(OH 2 )] n 1-n (n = 4, 5) complexes have been explored by using quantum chemical (QC) calculations at the ab initio level. The chemical bonding has been studied in the gas phase in order to eliminate solvent effects. QTAIM analysis demonstrates features that are very similar in all complexes and typical for electrostatic M-O bonds, but with the M-O bonds in the uranyl peroxide systems about 20 kJ mol -1 stronger than in the corresponding crown ether complexes. The regular decrease in bond strength with increasing M-O bond distance is consistent with predominantly electrostatic contributions. Energy decomposition of the reaction energies in the gas phase and solvent demonstrates that the predominant component of the total attractive (ΔE elec + ΔE orb ) energy contribution is the electrostatic component. There are no steric constraints for coordination of large cations to small rings, because the M + ions are located outside the ring plane, [O n ], formed by the oxygen donors in the ligands; coordination of ions smaller than the ligand cavity results in longer than normal M-O distances or in a change in the number of bonds, both resulting in weaker complexes. The Gibbs energies, enthalpies, and entropies of reaction calculated using the conductor-like screening model, COSMO, to account for solvent effects deviate significantly from experimental values in water, while those in acetonitrile are in much better agreement. Factors that might affect the selectivity are discussed, but our conclusion is that present QC methods are not accurate enough to describe the rather small differences in selectivity, which only amount to 5-10 kJ mol -1 . We can, however, conclude on the basis of QC and experimental data that M[crown ether] + complexes in the strongly coordinating water solvent are of outer-sphere type, [M(OH 2 ) n + ][crown ether], while those in weakly coordinating acetonitrile are of inner-sphere type, [M-crown ether] + . The observation that the M[UO 2 (O 2 )(OH)(OH 2 )] n 1-n complexes are more stable in solution than those of M[crown ether] + is an effect of the different charges of the rings.

  7. Crystal structures of two solvates of (18-crown-6)potassium acetate.

    PubMed

    Liebing, Phil; Zaeni, Ahmad; Olbrich, Falk; Edelmann, Frank T

    2016-12-01

    The crystal and mol-ecular strutures of two solvated forms of [K(18 c 6)]OAc (18 c 6 = 18-crown-6 = 1,4,7,10,13,16-hexa-oxa-cyclo-octa-decane and OAc = acetate) were determined by single-crystal X-ray diffraction, namely (acetato-κ 2 O , O ')(1,4,7,10,13,16-hexa-oxa-cyclo-octa-decane-κ 6 O )potassium dihydrate, [K(CH 3 COO)(C 12 H 24 O 6 )]·2H 2 O ( 1 ) and (acetato-κ 2 O , O ')aqua-(1,4,7,10,13,16-hexa-oxa-cyclo-octa-decane-κ 6 O )potassium acetic acid monosolvate [K(CH 3 COO)(C 12 H 24 O 6 )(H 2 O)]·CH 3 COOH ( 2 ). In both compounds, the acetate anion is bonded to the potassium ion in a chelating fashion and the metal atom is consequently slightly displaced from the O 6 plane of the crown ether. In the crystals, O-H⋯O hydrogen bonds lead to a polymeric ladder structure in the dihydrate 1 , while the acetic acid hydrate 2 features inversion dimers.

  8. Proton-Ionizable Crown Ethers. A Short Review

    DTIC Science & Technology

    1989-05-30

    acid methyl ester using sodium hydride as the base in tetrahydrofuran. The m3thyl ester group was hydrolyzed to the carboxylic acid as shown in Procedure...prepared via the appropriate hydroxydibenzo-crown ether and allyl bromide RýIý R2 or ethyl acrylate as shown in Procedure N. 5 2 . 5 6 Disulfonic acid ...similar to Procedure p. 7 4 Once the precursor binrephtho-crown was obtained, it was coupled with bromoacetic acid methyl ester and R, , - R

  9. Crystalline smectic E phase revisited in case of symmetrical dibenzo-18-crown-6-ether azomethine dimers

    NASA Astrophysics Data System (ADS)

    Cozan, Vasile; Ardeleanu, Rodinel; Airinei, Anton; Timpu, Daniel

    2018-03-01

    Three symmetric azomethine dimers having dibenzo-18-crown-6-ether as internal moiety and halogens (F, Cl, Br) as terminal functional groups were synthesized and characterized by FTIR and 1H NMR spectroscopy. Their thermal behavior was investigated by polarized optical microscopy (POM) and DSC techniques. Interesting textures have been observed at cooling by POM as being representative for a soft crystalline smectic phase. X-ray diffraction measurements in powder at room temperature exhibited a map of reflections corresponding to crystal E phase. The influence of molecular parameters (interdigitation parameter γ, dipole moment, molecular polarizability, halogen radius) on thermal behavior was discussed. The UV-Vis investigations allowed evaluation of photostability and a bathochromic effect was noticed with the increasing of halogen atom radius. Also the values of optical band gap (Eg) are higher than those corresponding to conjugated Schiff bases.

  10. Dual switchable CRET-induced luminescence of CdSe/ZnS quantum dots (QDs) by the hemin/G-quadruplex-bridged aggregation and deaggregation of two-sized QDs.

    PubMed

    Hu, Lianzhe; Liu, Xiaoqing; Cecconello, Alessandro; Willner, Itamar

    2014-10-08

    The hemin/G-quadruplex-catalyzed generation of chemiluminescence through the oxidation of luminol by H2O2 stimulates the chemiluminescence resonance energy transfer (CRET) to CdSe/ZnS quantum dots (QDs), resulting in the luminescence of the QDs. By the cyclic K(+)-ion-induced formation of the hemin/G-quadruplex linked to the QDs, and the separation of the G-quadruplex in the presence of 18-crown-6-ether, the ON-OFF switchable CRET-induced luminescence of the QDs is demonstrated. QDs were modified with nucleic acids consisting of the G-quadruplex subunits sequences and of programmed domains that can be cross-linked through hybridization, using an auxiliary scaffold. In the presence of K(+)-ions, the QDs aggregate through the cooperative stabilization of K(+)-ion-stabilized G-quadruplex bridges and duplex domains between the auxiliary scaffold and the nucleic acids associated with the QDs. In the presence of 18-crown-6-ether, the K(+)-ions are eliminated from the G-quadruplex units, leading to the separation of the aggregated QDs. By the cyclic treatment of the QDs with K(+)-ions/18-crown-6-ether, the reversible aggregation/deaggregation of the QDs is demonstrated. The incorporation of hemin into the K(+)-ion-stabilized G-quadruplex leads to the ON-OFF switchable CRET-stimulated luminescence of the QDs. By the mixing of appropriately modified two-sized QDs, emitting at 540 and 610 nm, the dual ON-OFF activation of the luminescence of the QDs is demonstrated.

  11. Cesium and strontium extraction using a mixed extractant solvent including crown ether and calixarene extractants

    DOEpatents

    Meikrantz, David H.; Todd, Terry A.; Riddle, Catherine L.; Law, Jack D.; Peterman, Dean R.; Mincher, Bruce J.; McGrath, Christopher A.; Baker, John D.

    2007-11-06

    A mixed extractant solvent including calix[4]arene-bis-(tert-octylbenzo)-crown-6 ("BOBCalixC6"), 4',4',(5')-di-(t-butyldicyclo-hexano)-18-crown-6 ("DtBu18C6"), and at least one modifier dissolved in a diluent. The mixed extractant solvent may be used to remove cesium and strontium from an acidic solution. The DtBu18C6 may be present from approximately 0.01 M to approximately 0.4M, such as from approximately 0.086 M to approximately 0.108 M. The modifier may be 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol ("Cs-7SB") and may be present from approximately 0.01M to approximately 0.8M. In one embodiment, the mixed extractant solvent includes approximately 0.15M DtBu18C6, approximately 0.007M BOBCalixC6, and approximately 0.75M Cs-7SB modifier dissolved in an isoparaffinic hydrocarbon diluent. The mixed extractant solvent may form an organic phase in an extraction system that also includes an aqueous phase. Methods of extracting cesium and strontium as well as strontium alone are also disclosed.

  12. Synthesis, characterization, and sol-gel entrapment of a crown ether-styryl fluoroionophore

    PubMed Central

    Sui, Zhijie; Hanan, Nathan J.; Phimphivong, Sam; Wysocki, Ronald J.; Saavedra, S. Scott

    2011-01-01

    The synthesis and initial evaluation of a new dye-functionalized crown-ether, 2-[2-(2,3,5,6,8,9,11,12,14,15-decahydro-1,4,7,10.13.16-benzohexaoxacyclooctadecin)ethenyl]-3-methyl benzothiazolium iodide (denoted BSD), is reported. This molecule contains a benzyl 18-crown-6 moiety as the ionophore and a benzothiazolium to spectrally transduce ion binding. Binding of K+ to BSD in methanol causes shifts in the both absorbance and fluorescence emission maxima, as well as changes in the molar absorptivity and the emission intensity. Apparent dissociation constants (Kd) in the range of 30 – 65 μM were measured. In water and neutral buffer, Kd values were approximately 1 mM. BSD was entrapped in sol-gel films composed of methyltriethoxysilane (MTES) and tetraethylorthosilicate (TEOS) with retention of its spectral properties and minimal leaching. K+ binding to BSD in sol-gels films immersed in pH 7.4 buffer causes significant fluorescence quenching, with an apparent response time of approximately 2 min and an apparent Kd of 1.5 mM. PMID:19253273

  13. Room temperature rechargeable magnesium batteries with sulfur-containing composite cathodes prepared from elemental sulfur and bis(alkenyl) compound having a cyclic or linear ether unit

    NASA Astrophysics Data System (ADS)

    Itaoka, Kanae; Kim, In-Tae; Yamabuki, Kazuhiro; Yoshimoto, Nobuko; Tsutsumi, Hiromori

    2015-11-01

    Room temperature rechargeable magnesium (Mg) batteries are constructed from Mg as a negative material, sulfur (S)-containing composite prepared from elemental sulfur and the bis(alkenyl) compound having a crown ether unit (BUMB18C6) or linear ether unit (UOEE) as a positive material and the simple electrolyte (0.7 mol dm-3 Mg[N(SO2CF3)2]2-triglyme (G3) solution). The reaction between molten S and the bis(alkenyl) compound (BUMB18C6 or UOEE) provides the sulfur-containing composite, S-BUMB18C6 or S-UOEE. Both of the sulfur-containing composites are electrochemically active in the Mg salt-based electrolyte, acetonitrile- or G3- Mg[N(SO2CF3)2]2 electrolyte. The first discharge capacity of the test cells with the sulfur-containing composite is 460 Ah kg-1 (per the weight of sulfur in the composite) with the S-BUMB18C6 electrode and 495 Ah kg-1 with the S-UOEE electrode. According to the continuous charge-discharge cycle tests (at 10th cycle), the discharge capacity of the test cell with the S-BUMB18C6 electrode (68.1 Ah kg-1) is higher than that with the S-UOEE electrode (0.18 Ah kg-1). The crown ether units in the S-BUMB18C6 composite may create ion-conducting paths in the cathode, prevent rise in the internal resistance of the cathode, and provide better cycle performance of the test cells with the S-BUMB18C6 composite electrode than that with the S-UOEE electrode.

  14. Novel Ordered Crown Ether-Containing Polyimides for Ion Conduction

    NASA Technical Reports Server (NTRS)

    Irvin, Jennifer A.; Stasko, Daniel; Fallis, Stephen; Guenthner, Andrew J.; Webber, Cynthia; Blackwell, John; Chvalun, Sergei N.

    2003-01-01

    We report the synthesis and characterization of thermally-stable polyimides for use as battery and fuel cell electrolyte membranes. Dianhydrides used were 1,4,5,8- naphthalenetetracarboxylic dianhydride and/or 4,4'-(hexafluoroisopropylidene)diphthalic anhydride. Diamines used were anti-4,4-diaminodibenzo-l8-crown-6, 4,4'- diaminodibenzo-24-crown-8, 2,2-bis(4-aminophenyl)hexafluoropropane, and/or 2,5- diaminobenzenesulfonic acid. The polymers were characterized using electrochemical impedance spectroscopy (EIS), thermal analysis and X-ray diffraction. Polymers containing the hexafluoroisopropylidene (HFIP) group were soluble in common organic solvents, while polymers without the HFIP group were very poorly soluble. Sulfonation yields polymers that are sparingly soluble in aqueous base and/or methanol. Degree of sulfonation, determined by titration, was between one and three sulfonate groups per repeat unit. Proton conductivity was determined as a function of water content, with a maximum conductivity of l x 10(exp -2) per centimeter when fully hydrated. Crown ether-containing polymers exhibit a high degree of order that may be indicative of crown ether channel formation, which may facilitate Li(+) transport for use in battery membranes.

  15. 30 s Response Time of K+ Ion-Selective Hydrogels Functionalized with 18-Crown-6 Ether Based on QCM Sensor.

    PubMed

    Zhang, Zhenxiao; Dou, Qian; Gao, Hongkai; Bai, Bing; Zhang, Yongmei; Hu, Debo; Yetisen, Ali K; Butt, Haider; Yang, Xiaoxia; Li, Congju; Dai, Qing

    2018-03-01

    Potassium detection is critical in monitoring imbalances in electrolytes and physiological status. The development of rapid and robust potassium sensors is desirable in clinical chemistry and point-of-care applications. In this study, composite supramolecular hydrogels are investigated: polyethylene glycol methacrylate and acrylamide copolymer (P(PEGMA-co-AM)) are functionalized with 18-crown-6 ether by employing surface initiated polymerization. Real-time potassium ion monitoring is realized by combining these compounds with quartz crystal microbalance. The device demonstrates a rapid response time of ≈30 s and a concentration detection range from 0.5 to 7.0 × 10 -3 m. These hydrogels also exhibit high reusability and K + ion selectivity relative to other cations in biofluids such as Na + , NH 4 + , Mg 2+ , and Ca 2+ . These results provide a new approach for sensing alkali metal ions using P(PEGMA-co-AM) hydrogels. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Crystal structures of dioxonium hexafluorotantalate and dioxonium hexafluoroniobate complexes with tetrabenzo-30-crown-10

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Furmanova, N. G., E-mail: furm@ns.crys.ras.ru; Rabadanov, M. Kh.; Chernaya, T. S.

    2008-03-15

    Two isostructural complexes of dioxonium [H{sub 5}O{sub 2}]{sup +} with tetrabenzo-30-crown-10 of the compositions [(tetrabenzo-30-crown-10 . H{sub 5}O{sub 2})][TaF{sub 6}] (I) and [(tetrabenzo-30-crown-10 . H{sub 5}O{sub 2})][NbF{sub 6}] (II) are studied using X-ray diffraction. The complexes crystallize in the monoclinic crystal system (space group C2/c, Z = 4). The unit cell parameters of these compounds are as follows: a = 15.6583(12) A, b = 15.2259(13) A, c = 16.4473(13) A, and {beta} = 99.398(6) deg. for complex I and a = 15.7117(12) A, b = 15.2785(15) A, c = 16.5247(15) A, and {beta} = 99.398(7) deg. for complex II. Thesemore » complexes belong to the ionic type. The dioxonium cation [H{sub 5}O{sub 2}]{sup +} in the form of the two-unit cluster [H{sub 3}O . H{sub 2}O]{sup +} is stabilized by the strong hydrogen bond OH-O [O-O, 2.353(4) A] and encapsulated by the crown ether. Each oxygen atom of the dioxonium cation also forms two oxygen bonds O-O(crown). The crown ether adopts an unusual two-level (pocket-like) conformation, which provides a complete encapsulation of the oxonium associate. The interaction of the cationic complex with the anion in the crystal occurs through contacts of the C-H-F type.« less

  17. Crystal structures of dioxonium hexafluorotantalate and dioxonium hexafluoroniobate complexes with tetrabenzo-30-crown-10

    NASA Astrophysics Data System (ADS)

    Furmanova, N. G.; Rabadanov, M. Kh.; Chernaya, T. S.; Fonari, M. S.; Simonov, Yu. A.; Ganin, É. V.; Gelmboldt, V. O.; Grigorash, R. Ya.; Kotlyar, S. A.; Kamalov, G. L.

    2008-03-01

    Two isostructural complexes of dioxonium [H5O2]+ with tetrabenzo-30-crown-10 of the compositions [(tetrabenzo-30-crown-10 · H5O2)][TaF6] ( I) and [(tetrabenzo-30-crown-10 · H5O2)][NbF6] ( II) are studied using X-ray diffraction. The complexes crystallize in the monoclinic crystal system (space group C2/ c, Z = 4). The unit cell parameters of these compounds are as follows: a = 15.6583(12) Å, b = 15.2259(13) Å, c = 16.4473(13) Å, and β = 99.398(6)° for complex I and a = 15.7117(12) Å, b = 15.2785(15) Å, c = 16.5247(15) Å, and β = 99.398(7)° for complex II. These complexes belong to the ionic type. The dioxonium cation [H5O2]+ in the form of the two-unit cluster [H3O · H2O]+ is stabilized by the strong hydrogen bond OH⋯O [O⋯O, 2.353(4) Å] and encapsulated by the crown ether. Each oxygen atom of the dioxonium cation also forms two oxygen bonds O⋯O(crown). The crown ether adopts an unusual two-level (pocket-like) conformation, which provides a complete encapsulation of the oxonium associate. The interaction of the cationic complex with the anion in the crystal occurs through contacts of the C-H⋯F type.

  18. Jet-cooled electronic and vibrational spectroscopy of crown ethers: benzo-15-crown-5 ether and 4'-amino-benzo-15-crown-5 ether.

    PubMed

    Shubert, V Alvin; James, William H; Zwier, Timothy S

    2009-07-16

    Laser-induced fluorescence (LIF), ultraviolet hole-burning (UVHB), and resonant ion-dip infrared (RIDIR) spectroscopies were carried out on isolated benzo-15-crown-5 ether (B15C) and 4'-amino-benzo-15-crown-5 ether (ABC) cooled in a supersonic expansion. Three conformational isomers of B15C and four of ABC were observed and spectroscopically characterized. Full optimizations and harmonic frequency calculations were undertaken for the full set of almost 1700 conformational minima identified in a molecular mechanics force field search. When compared with TDDFT predictions, the S(0)-S(1) origin positions serve as a useful diagnostic of the conformation of the crown ether near the phenyl ring responsible for the UV absorption and to the position of the NH(2) substituent. In-plane orientations for the beta carbons produce red-shifted S(0)-S(1) origins, while out-of-plane "buckling" produces substantial blue shifts of 600 cm(-1) or more. Comparison between the alkyl CH stretch spectra of B15C and ABC divide the spectra into common subgroups shared by the two molecules. The high-frequency CH stretch transitions (above 2930 cm(-1)) reflect the number of CH...O interactions, which in turn track in a general way the degree of buckling of the crown. On this basis, assignments of each of the observed conformational isomers to a class of structure can be made. All the observed structures have some degree of buckling to them, indicating that in the absence of a strong-binding partner, the crown folds in on itself to gain additional stabilization from weak dispersive and CH...O interactions.

  19. Conformational effect of dicyclo-hexano-18-crown-6 on isotopic fractionation of zinc: DFT approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boda, A.; Singha Deb, A. K.; Ali, Sk. M.

    2014-04-24

    Generalized gradient approximated BP86 density functional employing triple zeta valence plus polarization (TZVP) basis set has been used to compute the reduced partition function ratio and isotopic separation factor for zinc isotopes. The isotopic separation factor was found to be in good agreement with the experimental results. The isotopic separation factor was found to depend on the conformation of the crown ether ligand. The trans-trans conformation shows the highest fractionation compared to cis-cis conformer. The present theoretical results can thus be used to plan the isotope separation experiments.

  20. The Azocyanide Functional Group.

    DTIC Science & Technology

    1979-06-05

    unsymmetrical dienes; the regioisomer distributions of these unsymmetrical adducts have been correlated with the arylazocyanide ring sub- stituents using Hammet ...the crown ether also acts as a protecting group for the diazonium ion in solution ( equation 1). N NBF4 +[0N-N The efficiency of this protection has...reaction, equation 2) were dramatically slowed in the presence of crown ethers.1 2 However, crown ether solubilization and protection of ArN 2+BF4 hor

  1. Convenient approaches to synthesis of furanoid sugar-aza-crown ethers from C-ribosyl azido aldehyde via a reductive amination/amidation.

    PubMed

    Hsieh, Yu-Chi; Chir, Jiun-Ly; Zou, Wei; Wu, Hsiu-Han; Wu, An-Tai

    2009-05-26

    A short and highly efficient route to the alpha-anomer of a furanoid sugar-aza-crown ether was developed by a one-pot reductive amination of an alpha-anomer C-ribosyl azido aldehyde. In addition, the beta-anomer furanoid sugar-aza-crown ether was synthesized from a linear disaccharide precursor via amidation and then followed by microwave-assisted amide reduction.

  2. Mass dependence of calcium isotope fractionations in crown-ether resin chromatography.

    PubMed

    Fujii, Yasuhiko; Nomura, Masao; Kaneshiki, Tositaka; Sakuma, Yoichi; Suzuki, Tatsuya; Umehara, Saori; Kishimoto, Tadahumi

    2010-06-01

    Benzo 18-crown-6-ether resin was synthesised by the phenol condensation polymerisation process in porous silica beads, of which particle diameter was ca 60micro Calcium adsorption chromatography was performed with the synthesised resin packed in a glass column. The effluent was sampled in fractions, and the isotopic abundance ratios of (42)Ca, (43)Ca, (44)Ca, and (48)Ca against (40)Ca were measured by a thermo-ionisation mass spectrometer. The enrichment of heavier calcium isotopes was observed at the front boundary of calcium adsorption chromatogram. The mass dependence of mutual separation of calcium isotopes was analysed by using the three-isotope-plots method. The slopes of three-isotope-plots indicate the relative values of mutual separation coefficients for concerned isotopic pairs. The results have shown the normal mass dependence; isotope fractionation is proportional to the reduced mass difference, (M - M')/MM', where M and M' are masses of heavy and light isotope, respectively. The mass dependence clarifies that the isotope fractionations are originated from molecular vibration. The observed separation coefficient epsilon is 3.1x10(-3) for the pair of (40)Ca and (48)Ca. Productivity of enriched (48)Ca by crown-ether-resin was discussed as the function of the separation coefficient and the height equivalent to the theoretical plate.

  3. Aza-crown ether complex cation ionic liquids: preparation and applications in organic reactions.

    PubMed

    Song, Yingying; Cheng, Chen; Jing, Huanwang

    2014-09-26

    Aza-crown ether complex cation ionic liquids (aCECILs) were devised, fabricated, and characterized by using NMR spectroscopy, MS, thermogravimetric differential thermal analysis (TG-DTA), elemental analysis and physical properties. These new and room-temperature ILs were utilized as catalysts in various organic reactions, such as the cycloaddition reaction of CO2 to epoxides, esterification of acetic acid and alcohols, the condensation reaction of aniline and propylene carbonate, and Friedel-Crafts alkylation of indole with aldehydes were investigated carefully. In these reactions, the ionic liquid exhibited cooperative catalytic activity between the anion and cation. In addition, the aza-[18-C-6HK][HSO4]2 was the best acidic catalyst in the reactions of esterification and Friedel-Crafts alkylation under mild reaction conditions. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Biomedical potentials of crown ethers: prospective antitumor agents.

    PubMed

    Kralj, Marijeta; Tusek-Bozić, Ljerka; Frkanec, Leo

    2008-10-01

    Crown ethers are of enormous interest and importance in chemistry, biochemistry, materials science, catalysis, separation, transport and encapsulated processes, as well as in the design and synthesis of various synthetic systems with specific properties, diverse capabilities, and programmable functions. Classical crown ethers are macrocyclic polyethers that contain 3-20 oxygen atoms separated from each other by two or more carbon atoms. They are exceptionally versatile in selectively binding a range of metal ions and a variety of organic neutral and ionic species. Crown ethers are currently being studied and used in a variety of applications beyond their traditional place in chemistry. This review presents additional applications and the ever-increasing biomedical potentials of these intriguing compounds, with particular emphasis on the prospects of their relevance as anticancer agents. We believe that further research in this direction should be encouraged, as crown compounds could either induce toxicities that are different from those of conventional antitumor drugs, or complement drugs in current use, thereby providing a valuable adjunct to therapy.

  5. Magnetic isotope effect and theory of atomic orbital hybridization to predict a mechanism of chemical exchange reactions.

    PubMed

    Epov, Vladimir N

    2011-08-07

    A novel approach is suggested to investigate the mechanisms of chemical complexation reactions based on the results of Fujii with co-workers; they have experimentally observed that several metals and metalloids demonstrate mass-independent isotope fractionation during the reactions with the DC18C6 crown ether using solvent-solvent extraction. In this manuscript, the isotope fractionation caused by the magnetic isotope effect is used to understand the mechanisms of chemical exchange reactions. Due to the rule that reactions are allowed for certain electron spin states, and forbidden for others, magnetic isotopes show chemical anomalies during these reactions. Mass-independent fractionation is suggested to take place due to the hyperfine interaction of the nuclear spin with the electron spin of the intermediate product. Moreover, the sign of the mass-independent fractionation is found to be dependent on the element and its species, which is also explained by the magnetic isotope effect. For example, highly negative mass-independent isotope fractionation of magnetic isotopes was observed for reactions of DC18C6 with SnCl(2) species and with several Ru(III) chloro-species, and highly positive for reactions of this ether with TeCl(6)(2-), and with several Cd(II) and Pd(II) species. The atomic radius of an element is also a critical parameter for the reaction with crown ether, particularly the element ions with [Kr]4d(n)5s(m) electron shell fits the best with the DC18C6 crown ring. It is demonstrated that the magnetic isotope effect in combination with the theory of orbital hybridization can help to understand the mechanism of complexation reactions. The suggested approach is also applied to explain previously published mass-independent fractionation of Hg isotopes in other types of chemical exchange reactions. This journal is © the Owner Societies 2011

  6. A crown ether appended super gelator with multiple stimulus responsiveness.

    PubMed

    Dong, Shengyi; Zheng, Bo; Xu, Donghua; Yan, Xuzhou; Zhang, Mingming; Huang, Feihe

    2012-06-26

    A crown ether appended super gelator is designed and synthesized. It can gel a variety of organic solvents and shows excellent gelation properties with both low critical gelation concentration and short gelation time. Due to the introduction of the crown ether moiety and a secondary ammonium unit, the supramolecular gels show reversible gel-sol transitions. The supramolecular gels can also be molded into shape-persistent and free-standing objects. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Crystallization process of zeolite rho prepared by hydrothermal synthesis using 18-crown-6 ether as organic template.

    PubMed

    Araki, Sadao; Kiyohara, Yasato; Tanaka, Shunsuke; Miyake, Yoshikazu

    2012-06-15

    There are many viewpoints on the formation mechanisms for zeolites, but the details are not clear. An understanding of the elementary steps for their formation is important for the development of large-scale membranes and efficient manufacturing processes. In this study, the effects of silicon, aluminum, and the incorporation of 18-crown-6 (18C6) ether, on the formation of zeolite rho, using 18C6 as the structure directing agent (SDA) have been investigated by using field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray fluorescence spectrometry (EDX), nuclear magnetic resonance spectroscopy (NMR), thermo gravimetric analysis (TGA), and the pH measurement. These results suggested that a zeolite rho has four synthesis steps; (1) 0-3 h, the dehydration and condensation reaction between the silica and alumina to form amorphous aluminosilicates; (2) 3-20 h, the particle growth and aggregation process for the amorphous aluminosilicates; (3) 20-48 h, the crystallization and crystal growth of zeolite rho, with the incorporation of 18C6; and (4) 48-96 h, gentle growth with an increase in Na/Si ratio and a change in rate for the bounding state between the silica- and the alumina-based species. We consider the above to reflect the four steps for the formation of zeolite rho. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Aza crown ether compounds as anion receptors

    DOEpatents

    Lee, Hung Sui; Yang, Xiao-Oing; McBreen, James

    1998-08-04

    A family of aza-ether based compounds including linear, multi-branched and aza-crown ethers is provided. When added to non-aqueous battery electrolytes, the new family of aza-ether based compounds acts as neutral receptors to complex the anion moiety of the electrolyte salt thereby increasing the conductivity and the transference number of LI.sup.+ ion in alkali metal batteries.

  9. Aza crown ether compounds as anion receptors

    DOEpatents

    Lee, H.S.; Yang, X.O.; McBreen, J.

    1998-08-04

    A family of aza-ether based compounds including linear, multi-branched and aza-crown ethers is provided. When added to non-aqueous battery electrolytes, the new family of aza-ether based compounds acts as neutral receptors to complex the anion moiety of the electrolyte salt thereby increasing the conductivity and the transference number of LI{sup +} ion in alkali metal batteries. 3 figs.

  10. Crystal structures of dioxonium hexafluorotantalate and dioxonium hexafluoroniobate complexes with tetrabenzo-30-crown-10

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Furmanova, N. G., E-mail: furm@ns.crys.ras.ru; Rabadanov, M. Kh.; Chernaya, T. S.

    2008-03-15

    Two isostructural complexes of dioxonium [H{sub 5}O{sub 2}]{sup +} with tetrabenzo-30-crown-10 of the compositions [(tetrabenzo-30-crown-10 {center_dot} H{sub 5}O{sub 2})][TaF{sub 6}] (I) and [(tetrabenzo-30-crown-10 {center_dot} H{sub 5}O{sub 2})][NbF{sub 6}] (II) are studied using X-ray diffraction. The complexes crystallize in the monoclinic crystal system (space group C2/c, Z = 4). The unit cell parameters of these compounds are as follows: a = 15.6583(12) Angstrom-Sign , b = 15.2259(13) Angstrom-Sign , c = 16.4473(13) Angstrom-Sign , and {beta} = 99.398(6) Degree-Sign for complex I and a = 15.7117(12) Angstrom-Sign , b = 15.2785(15) Angstrom-Sign , c = 16.5247(15) Angstrom-Sign , and {beta} =more » 99.398(7) Degree-Sign for complex II. These complexes belong to the ionic type. The dioxonium cation [H{sub 5}O{sub 2}]{sup +} in the form of the two-unit cluster [H{sub 3}O {center_dot} H{sub 2}O]{sup +} is stabilized by the strong hydrogen bond OH Midline-Horizontal-Ellipsis O [O Midline-Horizontal-Ellipsis O, 2.353(4) Angstrom-Sign ] and encapsulated by the crown ether. Each oxygen atom of the dioxonium cation also forms two oxygen bonds O Midline-Horizontal-Ellipsis O(crown). The crown ether adopts an unusual two-level (pocket-like) conformation, which provides a complete encapsulation of the oxonium associate. The interaction of the cationic complex with the anion in the crystal occurs through contacts of the C-H Midline-Horizontal-Ellipsis F type.« less

  11. Examination and Manipulation of Protein Surface Charge in Solution with Electrospray Ionization Mass Spectrometry

    ERIC Educational Resources Information Center

    Gross, Deborah S.; Van Ryswyk, Hal

    2014-01-01

    Electrospray ionization mass spectrometry (ESI-MS) is a powerful tool for examining the charge of proteins in solution. The charge can be manipulated through choice of solvent and pH. Furthermore, solution-accessible, protonated lysine side chains can be specifically tagged with 18-crown-6 ether to form noncovalent adducts. Chemical derivatization…

  12. Highly K+ -Selective Fluorescent Probes for Lifetime Sensing of K+ in Living Cells.

    PubMed

    Schwarze, Thomas; Mertens, Monique; Müller, Peter; Riemer, Janine; Wessig, Pablo; Holdt, Hans-Jürgen

    2017-12-06

    The new K + -selective fluorescent probes 1 and 2 were obtained by Cu I -catalyzed 1,3-dipolar azide alkyne cycloaddition (CuAAC) reactions of an alkyne-substituted [1,3]dioxolo[4,5-f][1,3]benzodioxole (DBD) ester fluorophore with azido-functionalized N-phenylaza-18-crown-6 ether and N-(o-isopropoxy) phenylaza-18-crown-6 ether, respectively. Probes 1 and 2 allow the detection of K + in the presence of Na + in water by fluorescence enhancement (2.2 for 1 at 2000 mm K + and 2.5 for 2 at 160 mm K + ). Fluorescence lifetime measurements in the absence and presence of K + revealed bi-exponential decay kinetics with similar lifetimes, however with different proportions changing the averaged fluorescence decay times (τ f(av) ). For 1 a decrease of τ f(av) from 12.4 to 9.3 ns and for 2 an increase from 17.8 to 21.8 ns was observed. Variation of the substituent in ortho position of the aniline unit of the N-phenylaza-18-crown-6 host permits the modulation of the K d value for a certain K + concentration. For example, substitution of H in 1 by the isopropoxy group (2) decreased the K d value from >300 mm to 10 mm. 2 was chosen for studying the efflux of K + from human red blood cells (RBC). Upon addition of the Ca 2+ ionophor ionomycin to a RBC suspension in a buffer containing Ca 2+ , the fluorescence of 2 slightly rose within 10 min, however, after 120 min a significant increase was observed. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Small-angle neutron scattering study of specific interaction and coordination structure formed by mono-acetyl-substituted dibenzo-20-crown-6-ether and cesium ions

    DOE PAGES

    Motokawa, Ryuhei; Kobayashi, Tohru; Endo, Hitoshi; ...

    2015-10-26

    This study uses small-angle neutron scattering (SANS) to elucidate the coordination structure of the complex of mono-acetyl-substituted dibenzo-20-crown-6-ether (ace-DB20C6) with cesium ions (Cs +). SANS profiles obtained for the complex of ace-DB20C6 and Cs + (ace-DB20C6/Cs) in deuterated dimethyl sulfoxide indicated that Cs + coordination resulted in a more compact structure than the free ace-DB20C6. The data were fitted well with SANS profiles calculated using Debye function for scattering on an absolute scattering intensity scale. For this theoretical calculation of the scattering profiles, the coordination structure proposed based on density functional theory calculation was used. Furthermore, we conclude that themore » SANS analysis experimentally supports the proposed coordination structure of ace-DB20C6/Cs and suggests the following: (1) the complex of ace-DB20C6 and Cs + is formed with an ace-DB20C6/Cs molar ratio of 1/1 and (2) the two benzene rings of ace-DB20C6 fold around Cs + above the center of the crown ether ring of ace-DB20C6.« less

  14. Small-angle neutron scattering study of specific interaction and coordination structure formed by mono-acetyl-substituted dibenzo-20-crown-6-ether and cesium ions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Motokawa, Ryuhei; Kobayashi, Tohru; Endo, Hitoshi

    This study uses small-angle neutron scattering (SANS) to elucidate the coordination structure of the complex of mono-acetyl-substituted dibenzo-20-crown-6-ether (ace-DB20C6) with cesium ions (Cs +). SANS profiles obtained for the complex of ace-DB20C6 and Cs + (ace-DB20C6/Cs) in deuterated dimethyl sulfoxide indicated that Cs + coordination resulted in a more compact structure than the free ace-DB20C6. The data were fitted well with SANS profiles calculated using Debye function for scattering on an absolute scattering intensity scale. For this theoretical calculation of the scattering profiles, the coordination structure proposed based on density functional theory calculation was used. Furthermore, we conclude that themore » SANS analysis experimentally supports the proposed coordination structure of ace-DB20C6/Cs and suggests the following: (1) the complex of ace-DB20C6 and Cs + is formed with an ace-DB20C6/Cs molar ratio of 1/1 and (2) the two benzene rings of ace-DB20C6 fold around Cs + above the center of the crown ether ring of ace-DB20C6.« less

  15. Alkali metal cation complexation by 1,3-alternate, mono-ionisable calix[4]arene-benzocrown-6 compounds

    DOE PAGES

    Surowiec, Malgorzata A.; Custelcean, Radu; Surowiec, Kazimierz; ...

    2014-04-23

    Alkali metal cation extraction behavior for two series of 1,3-alternate, mono-ionizable calix[4]arene-benzocrown-6 compounds is examined. In Series 1, the proton-ionizable group is a substituent on the benzo group of the polyether ring that directs it away from the crown ether cavity. In Series 2, the proton-ionizable group is attached to one para position in the calixarene framework, thus positioning it over the crown ether ring. Competitive solvent extraction of alkali metal cations from aqueous solutions into chloroform shows high Cs+ efficiency and selectivity. Single-species extraction pH profiles of Cs+ for Series 1 and 2 ligands with the same proton-ionizable groupmore » are very similar. Thus, association of Cs+ with the calixcrown ring is more important than the the proton-ionizable group’s position in relation to the crown ether cavity. Solid-state structures are presented for two unionized ligands from Series 2, as is a crystal containing two different ionized ligand–Cs+ complexes.« less

  16. Utility of charge-transfer complexation for the assessment of macrocyclic polyethers: Spectroscopic, thermal and surface morphology characteristics of two highly crown ethers complexed with acido acceptors

    NASA Astrophysics Data System (ADS)

    Refat, Moamen S.; Adam, Abdel Majid A.; Saad, Hosam A.

    2015-04-01

    The study of the complexing ability of macrocyclic compounds to organic and inorganic substances is of great interest. The aim of this work is to provide basic data that can be used to the assessment of macrocyclic crown ethers quantitatively based on charge-transfer (CT) complexation. This goal was achieved by preparing CT complexes of two interesting mixed nitrogen-oxygen crown ethers with acido acceptors (chloranilic and picric acid), which were fully structurally characterized. The crown ethers are 4,7,13,16,21,24-hexaoxa-1,10-diazabicyclo[8.8.8]hexacosane (HDHC) and 1,4,10-trioxa-7,13-diaza-cyclopentadecane (TDPD). The obtained complexes were structurally characterized via elemental analysis, IR, Raman, 1H NMR, and UV-visible spectroscopy. Thermal properties of these complexes were also studied, and their kinetic thermodynamic parameters were calculated. Furthermore, the microstructure properties of these complexes have also been investigated using X-ray diffraction (XRD) and scanning electron microscope (SEM).

  17. Unusual centrosymmetric structure of [M(18-crown-6)](+) (M = Rb, Cs and NH4) complexes stabilized in an environment of hexachloridoantimonate(V) anions.

    PubMed

    Ponomarova, Vira V; Rusanova, Julia A; Rusanov, Eduard B; Domasevitch, Konstantin V

    2015-10-01

    In (1,4,7,10,13,16-hexaoxacyclooctadecane)rubidium hexachloridoantimonate(V), [Rb(C12H24O6)][SbCl6], (1), and its isomorphous caesium {(1,4,7,10,13,16-hexaoxacyclooctadecane)caesium hexachloridoantimonate(V), [Cs(C12H24O6)][SbCl6]}, (2), and ammonium {ammonium hexachloridoantimonate(V)-1,4,7,10,13,16-hexaoxacyclooctadecane (1/1), (NH4)[SbCl6]·C12H24O6}, (3), analogues, the hexachloridoantimonate(V) anions and 18-crown-6 molecules reside across -3 axes passing through the Sb atoms and the centroids of the 18-crown-6 groups, both of which coincide with centres of inversion. The Rb(+) [in (1)], Cs(+) [in (2)] and NH4(+) [in (3)] cations are situated inside the cavity of the 18-crown-6 ring; they are situated on -3 axes and are equally disordered about centres of inversion, deviating from the centroid of the 18-crown-6 molecule by 0.4808 (13), 0.9344 (7) and 0.515 (8) Å, respectively. Interaction of the ammonium cation and the 18-crown-6 group is supported by three equivalent hydrogen bonds [N...O = 2.928 (3) Å and N-H...O = 162°]. The centrosymmetric structure of [Cs(18-crown-6)](+), with the large Cs(+) cation approaching the centre of the ligand cavity, is unprecedented and accompanied by unusually short Cs-O bonds [2.939 (2) and 3.091 (2) Å]. For all three compounds, the [M(18-crown-6)](+) cations and [SbCl6](-) anions afford linear stacks along the c axis, with the cationic complexes embedded between pairs of inversion-related anions.

  18. "Crown Ether" Synthesis: An Organic Laboratory Experiment.

    ERIC Educational Resources Information Center

    Field, Kurt W.; And Others

    1979-01-01

    This experiment is designed to acquaint the student with a macromolecular synthesis of a crown ether type compound. The starting materials are readily available and the product, a cyclic polyether, belongs to a class of compounds that has aroused the interest of chemist and biologist alike. (Author/BB)

  19. A Series of F-Element Chelators; Diaza Crown Ethers Functionalized with Catecholate Binding Substituents

    DOE PAGES

    Stein, Benjamin W.; Cary, Samantha K.; Berg, John M.; ...

    2017-12-06

    Here, we report on the preparation of azacrown ethers functionalized with catechol groups. The synthetic approach was (1st) novel in that it made use of the Mannich reaction and (2nd) valuable in that it provided an improved synthesis (in terms of practical deployment) of the known N,N'-bis(2,3-dihydroxybenzyl)-4,13-diaza-18-crown-6, H 4ChaCha. Moreover, it demonstrated potential application of the synthetic method for accommodating a wide range of catecholate functionalities by using the synthetic strategy to prepare N,N'-bis(2,3-dihydroxy-5-tert-butylbenzyl)-4,13-diaza-18-crown-6 (H 4 tBu 2ChaCha) for the first time. These H 4ChaCha and H 4 tBu2ChaCha macrocycles offer exciting opportunity to expand redox chemistry for the f-elements.more » As “proof-of-principle,” we isolated the unusual tetrameric cluster [La 2( tBuChaCha) 2] 2 from reactions between H 4 tBu 2ChaCha and La[N(SiMe 3) 2] 3. Characterization of [La 2( tBuChaCha) 2] 2 by elemental analysis, single crystal X-ray diffraction, IR, and UV–vis–NIR spectroscopy suggested that the complex represented a rare example of an f-element semiquinone. It further demonstrated that the combination of La 3+ and H 4 tBu 2ChaCha provided access to one-electron oxidation chemistry within redox potential windows that were amenable to mild reaction conditions.« less

  20. A Series of F-Element Chelators; Diaza Crown Ethers Functionalized with Catecholate Binding Substituents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stein, Benjamin W.; Cary, Samantha K.; Berg, John M.

    Here, we report on the preparation of azacrown ethers functionalized with catechol groups. The synthetic approach was (1st) novel in that it made use of the Mannich reaction and (2nd) valuable in that it provided an improved synthesis (in terms of practical deployment) of the known N,N'-bis(2,3-dihydroxybenzyl)-4,13-diaza-18-crown-6, H 4ChaCha. Moreover, it demonstrated potential application of the synthetic method for accommodating a wide range of catecholate functionalities by using the synthetic strategy to prepare N,N'-bis(2,3-dihydroxy-5-tert-butylbenzyl)-4,13-diaza-18-crown-6 (H 4 tBu 2ChaCha) for the first time. These H 4ChaCha and H 4 tBu2ChaCha macrocycles offer exciting opportunity to expand redox chemistry for the f-elements.more » As “proof-of-principle,” we isolated the unusual tetrameric cluster [La 2( tBuChaCha) 2] 2 from reactions between H 4 tBu 2ChaCha and La[N(SiMe 3) 2] 3. Characterization of [La 2( tBuChaCha) 2] 2 by elemental analysis, single crystal X-ray diffraction, IR, and UV–vis–NIR spectroscopy suggested that the complex represented a rare example of an f-element semiquinone. It further demonstrated that the combination of La 3+ and H 4 tBu 2ChaCha provided access to one-electron oxidation chemistry within redox potential windows that were amenable to mild reaction conditions.« less

  1. Synthesis, Electrochemistry, and Reactivity of the Actinide Trisulfides [K(18-crown-6)][An(η(3)-S3)(NR2)3] (An = U, Th; R = SiMe3).

    PubMed

    Smiles, Danil E; Wu, Guang; Hayton, Trevor W

    2016-09-19

    The reaction of [Th(I)(NR2)3] (R = SiMe3) with [K(18-crown-6)]2[S4] results in the formation of [K(18-crown-6)][Th(η(3)-S3)(NR2)3] (2). Oxidation of 2, or its uranium analogue, [K(18-crown-6)][U(η(3)-S3)(NR2)3] (1), with AgOTf, in an attempt to generate an [S3](•-) complex, results in the formation of [K(18-crown-6)][An(OTf)2(NR2)3] (3, An = U; 4, An = Th) as the only isolable products. These results suggest that the putative [S3](•-) ligand is only weakly coordinating and can be easily displaced by nucleophiles.

  2. Syntheses, structures, and physicochemical properties of diruthenium compounds of tetrachlorocatecholate with metal-metal bonded Ru(3+)(mu-OR)(2)Ru(3+) and Ru(3.5+)(mu-OR)(2)Ru(3.5+) cores (R = CH(3) and C(2)H(5)).

    PubMed

    Miyasaka, H; Chang, H C; Mochizuki, K; Kitagawa, S

    2001-07-02

    Metal-metal bonded Ru(3+)(mu-OR)(2)Ru(3+) and Ru(3.5+)(mu-OR)(2)Ru(3.5+) (R = CH(3) and CH(3)CH(2)) compounds with tetrachlorocatecholate (Cl(4)Cat) have been synthesized in the corresponding alcohol, MeOH and EtOH, from a nonbridged Ru(2+)-Ru(3+) compound, Na(3)[Ru(2)(Cl(4)Cat)(4)(THF)].3H(2)O.7THF (1). In alcohol solvents, compound 1 is continuously oxidized by oxygen to form Ru(3+)(mu-OR)(2)Ru(3+) and Ru(3.5+)(mu-OR)(2)Ru(3.5+) species. The presence of a characteristic countercation leads to selective isolation of either Ru(3+)(mu-OR)(2)Ru(3+) or Ru(3.5+)(mu-OR)(2)Ru(3.5+) as a stable adduct species. In methanol, Ph(4)PCl and dibenzo-18-crown-6-ether afford Ru(3+)(mu-OMe)(2)Ru(3+) species, [A](2)[Ru(2)(Cl(4)Cat)(4)(mu-OMe)(2)Na(2)(MeOH)(6)] ([A](+) = Ph(4)P(+) (2), [Na(dibenzo-18-crown-6)(H(2)O)(MeOH)](+) (3)), while benzo-15-crown-5-ether provides a Ru(3.5+)(mu-OMe)(2)Ru(3.5+) species, [Na(benzo-15-crown-5)(2)][Ru(2)(Cl(4)Cat)(4)(mu-OMe)(2)Na(2)(MeOH)(6)] (4). The air oxidation of 1 in a MeOH/EtOH mixed solvent (1:1 v/v) containing benzo-15-crown-5-ether provides a Ru(3.5+)(mu-OMe)(2)Ru(3.5+) species, [Na(benzo-15-crown-5)(H(2)O)][Ru(2)(Cl(4)Cat)(2)(mu-OMe)(2)Na(2)(EtOH)(2)(H(2)O)(2)(MeOH)(2)].(benzo-15-crown-5) (5). Similarly, the oxidation of 1 in ethanol with Ph(4)PCl provides a Ru(3.5+)(mu-OEt)(2)Ru(3.5+) species, (Ph(4)P)[Ru(2)(Cl(4)Cat)(4)(mu-OEt)(2)Na(2)(EtOH)(6)] (7). A selective formation of a Ru(3+)(mu-OEt)(2)Ru(3+) species, (Ph(4)P)(2)[Ru(2)(Cl(4)Cat)(4)(mu-OEt)(2)Na(2)(EtOH)(2)(H(2)O)(2)] (6), is found in the presence of pyrazine or 2,5-dimethylpyrazine. The crystal structures of these compounds, except 2 and 7, have been determined by X-ray crystallography, and all compounds have been characterized by several spectroscopic and magnetic investigations. The longer Ru-Ru bonds are found in the Ru(3+)(mu-OR)(2)Ru(3+) species (2.606(1) and 2.628(2) A for 3 and 6, respectively) compared with those of Ru(3.5+)(mu-OMe)(2)Ru(3.5+) species (2.5260(6) A and 2.514(2) A for 4 and 5, respectively). These structural features and magnetic and ESR data revealed the electronic configurations of sigma(2)pi(2)delta(2)delta(2)pi(2) and sigma(2)pi(2)delta(2)delta(2)pi(1) for Ru(3+)(mu-OR)(2)Ru(3+) and Ru(3.5+)(mu-OR)(2)Ru(3.5+), respectively, in which the former is diamagnetic and the latter is paramagnetic with S = (1)/(2) ground state. Compound 5 forms a one-dimensional chain with alternating arrangement of a Ru(3.5+)(mu-OMe)(2)Ru(3.5+) unit and a free benzo-15-crown-5-ether molecule by intermolecular hydrogen bonds (O(H(2)O).O(crown-ether) = 2.91-3.04 A). The cyclic voltammetry in DMF affords characteristic metal-origin voltammograms; two reversible and two quasi-reversible redox waves were observed. The feature of cyclic voltammograms for the Ru(3+)(mu-OR)(2)Ru(3+) species (2, 3, and 6) and the Ru(3.5+)(mu-OR)(2)Ru(3.5+) species (4 and 7) are similar to each other, indicating that both species are electrochemically stable. The isolation of the pyrazine-trans-coordinated species, [Ph(4)P][Ru(Cl(4)Cat)(2)(L)(2)] (L = pyrazine (8), 2,5-dimethylpyrazine (9)), revealed the selective isolation of 6 from pyrazine-containing solution. UV-vis spectral variation by ethanolysis for 9 demonstrated the selective conversion from the pyrazine-trans-coordinated species to the Ru(3+)(mu-OEt)(2)Ru(3+) species without an oxidation to the Ru(3.5+)(mu-OEt)(2)Ru(3.5+) species. This result suggests the presence of equilibrium between [Ru(Cl(4)Cat)(2)(L)(2)](-) and Ru(3+)(mu-OEt)(2)Ru(3+) species in the synthetic condition for 6.

  3. Host-guest chemistry for tuning colloidal solubility, self-organization and photoconductivity of inorganic-capped nanocrystals

    NASA Astrophysics Data System (ADS)

    Bodnarchuk, Maryna I.; Yakunin, Sergii; Piveteau, Laura; Kovalenko, Maksym V.

    2015-12-01

    Colloidal inorganic nanocrystals (NCs), functionalized with inorganic capping ligands, such as metal chalcogenide complexes (MCCs), have recently emerged as versatile optoelectronic materials. As-prepared, highly charged MCC-capped NCs are dispersible only in highly polar solvents, and lack the ability to form long-range ordered NC superlattices. Here we report a simple and general methodology, based on host-guest coordination of MCC-capped NCs with macrocyclic ethers (crown ethers and cryptands), enabling the solubilization of inorganic-capped NCs in solvents of any polarity and improving the ability to form NC superlattices. The corona of organic molecules can also serve as a convenient knob for the fine adjustment of charge transport and photoconductivity in films of NCs. In particular, high-infrared-photon detectivities of up to 3.3 × 1011 Jones with a fast response (3 dB cut-off at 3 kHz) at the wavelength of 1,200 nm were obtained with films of PbS/K3AsS4/decyl-18-crown-6 NCs.

  4. Functionalized Derivatives of Benzo-Crown Ethers. Part 4. Antifungal Macrocyclic Supramolecular Complexes of Transition Metal Ions Acting as Lanosterol-14-α-Demethylase Ihibitors

    PubMed Central

    Barboiu, Mihai; Scozzafava, Andrea; Guran, Cornelia; Diaconescu, Paula; Bojin, Mihaela; Iluc, Vlad; Cot, Louis

    1999-01-01

    Poly- and mononuclear metal complexes of 2,3,11,12-bis[4-(10-aminodecylcarbonyl)]benzo-18- crown-6 (L) and Cu(II); Ni(II); Co(II) and Cr(III) have been synthesized and characterized by standard physico-chemical procedures. In the newly prepared complexes the crown moiety oxygen atoms of the macrocyclic host did not generally interact with metal ions, whereas the two amino groups of the ligand always did. Several of the newly synthesized compounds act as effective antifungal agents against Aspergillus and Candida spp., some of them showing activities comparable to ketoconazole, with minimum inhibitory concentrations in the range of 0.3−0.5 μg/mL. The mechanism of antifungal action of these coordination compounds is probably connected to an inhibition of lanosterol-14-α-demethylase, a metallo-enzyme playing a key role in sterol biosynthesis in fungi, bacteria and eukariotes. PMID:18475888

  5. Electron spin resonance and proton matrix electron nuclear double resonance studies of N,N,N[prime],N[prime]-tetramethylbenzidine photoionization in sodium and lithium dodecyl sulfate micelles: Structural effects of crown ethers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McManus, H.J.D.; Young Soo Kang; Kevan, L.

    1993-01-07

    The study of model membrane systems enjoys increasing attention within the area of solar energy research. An electron nuclear double resonance and electron spin resonance study of photogenerated N,N,N[prime],N[prime]-tetramethylbenzidine (TMB) cation in frozen suspensions of lithium (LDS) and sodium (SDS) dodecyl sulfate micelles containing various concentrations of cyclic polyethers was undertaken. The relative location of the TMB cation within the organic aggregate was determined from the proton matrix ENDOR line width at 142 K. A broader line width was observed in LDS compared to SDS micelles, which is due to the fact that the larger lithium cation opens the micellarmore » interface resulting in increased hydration and deeper solubilization of TMB. The proton matrix ENDOR line width decreased upon addition of crown ethers. This decrease may be explained by displacement of the TMB toward the interface as a result of the decrease in ionic strength caused by the complexation of the countercations. The photoyield shows a slight increase with addition of crown ethers. This increase is most likely caused by the increase in the effective anionic charge of the micelle effected by the complexation of the sodium or lithium ions by the crown ethers. This increase in the anionic charge mitigates the rate of thermal back electron transfer resulting in an increased photoyield. 54 refs., 6 figs., 2 tabs.« less

  6. Isolation of Mn(I) Compounds Featuring a Reduced Bis(imino)pyridine Chelate and Their Relevance to Electrocatalytic Hydrogen Production.

    PubMed

    Mukhopadhyay, Tufan K; MacLean, Nicholas L; Flores, Marco; Groy, Thomas L; Trovitch, Ryan J

    2018-05-21

    We report the preparation and electronic structure determination of chelate-reduced Mn(I) compounds that are relevant to electrocatalytic proton reduction mediated by [( Ph2PPr PDI)Mn(CO)][Br]. Reducing [( Ph2PPr PDI)Mn(CO)][Br] with excess Na-Hg afforded a neutral paramagnetic complex, ( Ph2PPr PDI)Mn(CO). This compound was found to feature a low spin Mn(I) center and a PDI radical anion as determined by magnetic susceptibility measurement (1.97 μ B ), EPR spectroscopy ( S = 1 / 2 ), and density functional theory calculations. When [( Ph2PPr PDI)Mn(CO)][Br] was reduced with K-Hg, Mn(I) complexes with highly activated CO ligands were obtained. Recrystallization of the reduced product from diethyl ether solution allowed for the isolation of dimeric [(κ 4 - Ph2PPr PDI)Mn(μ-η 1 ,η 1 ,η 2 -CO)K(Et 2 O)] 2 (ν CO = 1710 cm -1 , 1656 cm -1 ), while methyl tert-butyl ether treatment afforded dimeric [(κ 4 - Ph2PPr PDI)Mn(μ-η 1 ,η 1 -CO)K(MTBE) 2 ] 2 (ν CO = 1695 cm -1 , MTBE = methyl tert-butyl ether). Addition of 18-crown-6 to these products, or conducting the K-Hg reduction of [( Ph2PPr PDI)Mn(CO)][Br] in the presence of 18-crown-6, allowed for the isolation of a monomeric example, (κ 4 - Ph2PPr PDI)Mn(μ-η 1 ,η 2 -CO)K(18-crown-6) (ν CO = 1697 cm -1 ). All three complexes were found to be diamagnetic and were characterized thoroughly by multinuclear 1D and 2D NMR spectroscopy and single crystal X-ray diffraction. Detailed analysis of the metrical parameters and spectroscopic properties suggest that all three compounds possess a Mn(I) center that is supported by a PDI dianion. Importantly, (κ 4 - Ph2PPr PDI)Mn(μ-η 1 ,η 2 -CO)K(18-crown-6) was found to react instantaneously with either HBF 4 ·OEt 2 or HOTf to evolve H 2 and generate the corresponding Mn(I) complex, [( Ph2PPr PDI)Mn(CO)][BF 4 ] or [( Ph2PPr PDI)Mn(CO)][OTf], respectively. These products are spectroscopically and electrochemically similar to previously reported [( Ph2PPr PDI)Mn(CO)][Br]. It is believed that the mechanism of [( Ph2PPr PDI)Mn(CO)][Br]-mediated proton reduction involves intermediates that are related to the compounds described herein and that their ambient temperature isolation is aided by the redox active nature of Ph2PPr PDI.

  7. Schiff's Bases and Crown Ethers as Supramolecular Sensing Materials in the Construction of Potentiometric Membrane Sensors

    PubMed Central

    Faridbod, Farnoush; Ganjali, Mohammad Reza; Dinarvand, Rassoul; Norouzi, Parviz; Riahi, Siavash

    2008-01-01

    Ionophore incorporated PVC membrane sensors are well-established analytical tools routinely used for the selective and direct measurement of a wide variety of different ions in complex biological and environmental samples. Potentiometric sensors have some outstanding advantages including simple design and operation, wide linear dynamic range, relatively fast response and rational selectivity. The vital component of such plasticized PVC members is the ionophore involved, defining the selectivity of the electrodes' complex formation. Molecular recognition causes the formation of many different supramolecules. Different types of supramolecules, like calixarenes, cyclodextrins and podands, have been used as a sensing material in the construction of ion selective sensors. Schiff's bases and crown ethers, which feature prominently in supramolecular chemistry, can be used as sensing materials in the construction of potentiometric ion selective electrodes. Up to now, more than 200 potentiometric membrane sensors for cations and anions based on Schiff's bases and crown ethers have been reported. In this review cation binding and anion complexes will be described. Liquid membrane sensors based on Schiff's bases and crown ethers will then be discussed. PMID:27879786

  8. Dibenzo-18-crown-6–picric acid–water (1/2/3)

    PubMed Central

    Saleh, Muhammad Idiris; Kusrini, Eny; Rosli, Mohd Mustaqim; Fun, Hoong-Kun

    2008-01-01

    In the crown ether ring of the title compound, C20H24O6·2C6H3N3O7·3H2O, the O—C(H2)—C(H2)—O torsion angles indicate a gauche conformation of the ethyl­eneoxy units, while the C—O—C—C torsion angles indicate planarity of these segments; the dihedral angle between the two benzene rings is 44.53 (13)°. In both picric acid mol­ecules, one of the nitro groups is twisted away from the attached ring. The mol­ecules are linked into chains along the b axis via inter­molecular O—H⋯O hydrogen bonds. In addition, the crystal structure is stabilized by C—H⋯O hydrogen bonds and π–π inter­actions [centroid–centroid distance between benzene rings = 3.5697 (16) Å]. PMID:21202944

  9. Water-soluble polymers and compositions thereof

    DOEpatents

    Smith, B.F.; Robison, T.W.; Gohdes, J.W.

    1999-04-06

    Water-soluble polymers including functionalization from the group of amino groups, carboxylic acid groups, phosphonic acid groups, phosphonic ester groups, acylpyrazolone groups, hydroxamic acid groups, aza crown ether groups, oxy crown ethers groups, guanidinium groups, amide groups, ester groups, aminodicarboxylic groups, permethylated polyvinylpyridine groups, permethylated amine groups, mercaptosuccinic acid groups, alkyl thiol groups, and N-alkylthiourea groups are disclosed.

  10. Water-soluble polymers and compositions thereof

    DOEpatents

    Smith, Barbara F.; Robison, Thomas W.; Gohdes, Joel W.

    2002-01-01

    Water-soluble polymers including functionalization from the group of amino groups, carboxylic acid groups, phosphonic acid groups, phosphonic ester groups, acylpyrazolone groups, hydroxamic acid groups, aza crown ether groups, oxy crown ethers groups, guanidinium groups, amide groups, ester groups, aminodicarboxylic groups, permethylated polvinylpyridine groups, permethylated amine groups, mercaptosuccinic acid groups, alkyl thiol groups, and N-alkylthiourea groups are disclosed.

  11. Water-soluble polymers and compositions thereof

    DOEpatents

    Smith, Barbara F.; Robison, Thomas W.; Gohdes, Joel W.

    1999-01-01

    Water-soluble polymers including functionalization from the group of amino groups, carboxylic acid groups, phosphonic acid groups, phosphonic ester groups, acylpyrazolone groups, hydroxamic acid groups, aza crown ether groups, oxy crown ethers groups, guanidinium groups, amide groups, ester groups, aminodicarboxylic groups, permethylated polyvinylpyridine groups, permethylated amine groups, mercaptosuccinic acid groups, alkyl thiol groups, and N-alkylthiourea groups are disclosed.

  12. Alkaline-side extraction of technetium from tank waste using crown ethers and other extractants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonnesen, P.V.; Moyer, B.A.; Presley, D.J.

    The chemical development of a new crown-ether-based solvent-extraction process for the separation of (Tc) from alkaline tank-waste supernate is ready for counter-current testing. The process addresses a priority need in the proposed cleanup of Hanford and other tank wastes. This need has arisen from concerns due to the volatility of Tc during vitrification, as well as {sup 99}Tc`s long half-life and environmental mobility. The new process offers several key advantages that direct treatability--no adjustment of the waste composition is needed; economical stripping with water; high efficiency--few stages needed; non-RCRA chemicals--no generation of hazardous or mixed wastes; co-extraction of {sup 90}Sr;more » and optional concentration on a resin. A key concept advanced in this work entails the use of tandem techniques: solvent extraction offers high selectivity, while a subsequent column sorption process on the aqueous stripping solution serves to greatly concentrate the Tc. Optionally, the stripping solution can be evaporated to a small volume. Batch tests of the solvent-extraction and stripping components of the process have been conducted on actual melton Valley Storage Tank (MVST) waste as well as simulants of MVST and Hanford waste. The tandem process was demonstrated on MVST waste simulants using the three solvents that were selected the final candidates for the process. The solvents are 0.04 M bis-4,4{prime}(5{prime})[(tert-butyl)cyclohexano]-18-crown-6 (abbreviated di-t-BuCH18C6) in a 1:1 vol/vol blend of tributyl phosphate and Isopar{reg_sign} M (an isoparaffinic kerosene); 0.02 M di-t-BuCH18C6 in 2:1 vol/vol TBP/Isopar M and pure TBP. The process is now ready for counter-current testing on actual Hanford tank supernates.« less

  13. Probing Supramolecular Interactions between a Crown Ether Appended Zinc Phthalocyanine and an Ammonium Group Appended to a C60 Derivative.

    PubMed

    Lederer, Marcus; Hahn, Uwe; Strub, Jean-Marc; Cianférani, Sarah; Van Dorsselaer, Alain; Nierengarten, Jean-François; Torres, Tomas; Guldi, Dirk M

    2016-02-01

    Self-assembly driven by crown ether complexation of zinc phthalocyanines equipped with one 18-crown-6 moiety and fullerenes bearing an ammonium head group afforded a novel donor-acceptor hybrid. In reference experiments, fullerenes containing a Boc-protected amine functionality have been probed. The circumvention of zinc phthalocyanine aggregation is important for the self-assembly, which required the addition of pyridine. From absorption and fluorescence titration assays, which provided sound and unambiguous evidence for mutual interactions between the electron donor and the electron acceptor within the hybrids, association constants in the order of 8.0×10 5  m -1 have been derived. The aforementioned is based on 1:1 stoichiometries, which have been independently confirmed by Job's plot measurements. In the excited state, which has been examined by transient absorption experiments, intermolecular charge separation evolves from the photoexcited zinc phthalocyanine to the fullerene subunit and leads to short-lived charge-separated states. Interestingly, photoexcitation of zinc phthalocyanine dimers/aggregates can also be followed by an intermolecular charge separation between vicinal phthalocyanines. These multicomponent supramolecular ensembles have also been shown by in-depth electrospray ionization mass spectrometry (ESI-MS) studies, giving rise to the formation and detection of a variety of non-covalently linked species. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Increasing the thermopower of crown-ether-bridged anthraquinones.

    PubMed

    Ismael, Ali K; Grace, Iain; Lambert, Colin J

    2015-11-07

    We investigate strategies for increasing the thermopower of crown-ether-bridged anthraquinones. The novel design feature of these molecules is the presence of either () crown-ether or () diaza-crown-ether bridges attached to the side of the current-carrying anthraquinone wire. The crown-ether side groups selectively bind alkali-metal cations and when combined with TCNE or TTF dopants, provide a large phase-space for optimising thermoelectric properties. We find that the optimum combination of cations and dopants depends on the temperature range of interest. The thermopowers of both and are negative and at room temperature are optimised by binding with TTF alone, achieving thermpowers of -600 μV K(-1) and -285 μV K(-1) respectively. At much lower temperatures, which are relevant to cascade coolers, we find that for , a combination of TTF and Na(+) yields a maximum thermopower of -710 μV K(-1) at 70 K, whereas a combination of TTF and Li(+) yields a maximum thermopower of -600 μV K(-1) at 90 K. For , we find that TTF doping yields a maximum thermopower of -800 μV K(-1) at 90 K, whereas at 50 K, the largest thermopower (of -600 μV K(-1)) is obtain by a combination TTF and K(+) doping. At room temperature, we obtain power factors of 73 μW m(-1) K(-2) for (in combination with TTF and Na(+)) and 90 μW m(-1) K(-2) for (with TTF). These are higher or comparable with reported power factors of other organic materials.

  15. Persistent organic pollutants in red-crowned cranes (Grus japonensis) from Hokkaido, Japan.

    PubMed

    Kakimoto, Kensaku; Akutsu, Kazuhiko; Nagayoshi, Haruna; Konishi, Yoshimasa; Kajimura, Keiji; Tsukue, Naomi; Yoshino, Tomoo; Matsumoto, Fumio; Nakano, Takeshi; Tang, Ning; Hayakawa, Kazuichi; Toriba, Akira

    2018-01-01

    The red-crowned crane (Grus japonensis) from eastern Hokkaido is classified as a Special Natural Monument in Japan. In this study, we determined the concentrations of persistent organic pollutants (POPs) in red-crowned crane muscle tissues (n = 47). Polychlorinated biphenyls (PCBs) had the highest median concentration (240ng/g lipid weight), followed by dichlorodiphenyltrichloroethane and its metabolites (DDTs) (150ng/g lipid weight), chlordane-related compounds (CHLs) (36ng/g lipid weight), hexachlorobenzene (HCB) (16ng/g lipid weight), hexachlorocyclohexanes (HCHs) (4.4ng/g lipid weight), polybrominated diphenyl ethers (PBDEs) (1.8ng/g lipid weight), and finally, Mirex (1.5ng/g lipid weight). Additionally, a positive correlation was found among POP concentrations. No sex differences beyond body parameters were observed. Additionally, red-crowned cranes exhibited a high enantiomeric excess of (+)-alpha-HCH, with enantiomer fractions varying from 0.51 to 0.87 (average: 0.69). Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Host-guest chemistry for tuning colloidal solubility, self-organization and photoconductivity of inorganic-capped nanocrystals.

    PubMed

    Bodnarchuk, Maryna I; Yakunin, Sergii; Piveteau, Laura; Kovalenko, Maksym V

    2015-12-09

    Colloidal inorganic nanocrystals (NCs), functionalized with inorganic capping ligands, such as metal chalcogenide complexes (MCCs), have recently emerged as versatile optoelectronic materials. As-prepared, highly charged MCC-capped NCs are dispersible only in highly polar solvents, and lack the ability to form long-range ordered NC superlattices. Here we report a simple and general methodology, based on host-guest coordination of MCC-capped NCs with macrocyclic ethers (crown ethers and cryptands), enabling the solubilization of inorganic-capped NCs in solvents of any polarity and improving the ability to form NC superlattices. The corona of organic molecules can also serve as a convenient knob for the fine adjustment of charge transport and photoconductivity in films of NCs. In particular, high-infrared-photon detectivities of up to 3.3 × 10(11) Jones with a fast response (3 dB cut-off at 3 kHz) at the wavelength of 1,200 nm were obtained with films of PbS/K3AsS4/decyl-18-crown-6 NCs.

  17. Host–guest chemistry for tuning colloidal solubility, self-organization and photoconductivity of inorganic-capped nanocrystals

    PubMed Central

    Bodnarchuk, Maryna I.; Yakunin, Sergii; Piveteau, Laura; Kovalenko, Maksym V.

    2015-01-01

    Colloidal inorganic nanocrystals (NCs), functionalized with inorganic capping ligands, such as metal chalcogenide complexes (MCCs), have recently emerged as versatile optoelectronic materials. As-prepared, highly charged MCC-capped NCs are dispersible only in highly polar solvents, and lack the ability to form long-range ordered NC superlattices. Here we report a simple and general methodology, based on host–guest coordination of MCC-capped NCs with macrocyclic ethers (crown ethers and cryptands), enabling the solubilization of inorganic-capped NCs in solvents of any polarity and improving the ability to form NC superlattices. The corona of organic molecules can also serve as a convenient knob for the fine adjustment of charge transport and photoconductivity in films of NCs. In particular, high-infrared-photon detectivities of up to 3.3 × 1011 Jones with a fast response (3 dB cut-off at 3 kHz) at the wavelength of 1,200 nm were obtained with films of PbS/K3AsS4/decyl-18-crown-6 NCs. PMID:26647828

  18. Interaction of Cesium Ions with Calix[4]arene-bis(t-octylbenzo-18-crown-6): NMR and Theoretical Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kriz, Jaroslav; Dybal, Jiri; Vanura, Petr

    2011-01-01

    Using 1H, 13C, and 133Cs NMR spectra, it is shown that calix[4]arene-bis (t-octylbenzo-18-crown-6) (L) forms complexes with one (L 3 Cs ) and two (L 3 2Cs ) Cs ions offered by cesium bis(1,2-dicarbollide) cobaltate (CsDCC) in nitrobenzene-d5. The ions interact with all six oxygen atoms in the crown-ether ring and the electrons of the calixarene aromatic moieties. According to extraction technique, the stability constant of the first complex is log nb(L 3 Cs ) = 8.8 ( 0.1. According to 133Cs NMR spectra, the value of the equilibrium constant of the second complex is log Knb (2)(L 3 2Csmore » ) = 6.3(0.2, i.e., its stabilization constant is log nb(L 3 2Cs ) = 15.1 ( 0.3. Self-diffusion measurements by 1H pulsed-field gradient (PFG) NMRcombined with density functional theory (DFT) calculations suggest that one DCC ion is tightly associated with L 3 Cs , decreasing its positive charge and consequently stabilizing the second complex, L 3 2Cs . Using a saturation-transfer 133Cs NMR technique, the correlation times ex of chemical exchange between L 3 Cs and L 3 2Cs as well as between L 3 2Cs and free Cs ions were determined as 33.6 and 29.2 ms, respectively.« less

  19. Ion pair recognition by Zn-porphyrin/crown ether conjugates: visible sensing of sodium cyanide.

    PubMed

    Kim, Yeon-Hwan; Hong, Jong-In

    2002-03-07

    Synthesis and complexation behavior of ditopic neutral receptors composed of both a Lewis-acidic binding site (zinc porphyrin moiety) and a Lewis-basic binding site (crown ether moiety) are reported; the receptors bound only NaCN in a ditopic fashion with a color change, and in contrast other sodium salts bound to the receptors in a monotopic fashion without a color change.

  20. Secondary Li battery incorporating 12-Crown-4 ether

    NASA Technical Reports Server (NTRS)

    Nagasubramanian, Ganesan (Inventor); Distefano, Salvador (Inventor)

    1992-01-01

    A rechargeable lithium battery which utilizes a polyethylene oxide (PEO) solid polymeric electrolyte complexed with a lithium salt is disclosed. The conductivity is increased an order of magnitude and interfacial charge transfer resistance is substantially decreased by incorporating a minor amount of 12-Crown-4 ether in the PEO-lithium salt solid electrolyte film. Batteries containing the improved electrolyte permit operation at a lower temperature with improved efficiency.

  1. Separation of thorium from lanthanides by solvent extraction with ionizable crown ethers.

    PubMed

    Du, H S; Wood, D J; Elshani, S; Wai, C M

    1993-02-01

    Thorium and the lanthanides are extracted by alpha-(sym-dibenzo-16-crown-5-oxy)acetic acid and its analogues in different pH ranges. At pH 4.5, Th is quantitatively extracted by the crown ether carboxylic acids into chloroform whereas the extraction of the lanthanides is negligible. Separation of Th from the lanthanides can be achieved by solvent extraction under this condition. The extraction does not require specific counteranions and is reversible with respect to pH. Trace amounts of Th in water can be quantitatively recovered using this extraction system for neutron activation analysis. The nature of the extracted Th complex and the mechanism of extraction are discussed.

  2. Efficient removal of caesium ions from aqueous solution using a calix crown ether in ionic liquids: mechanism and radiation effect.

    PubMed

    Xu, Chao; Yuan, Liyong; Shen, Xinghai; Zhai, Maolin

    2010-04-28

    The removal of radioactive (137)Cs from nuclear waste is of great importance for both the environment and energy saving. Herein, we report a study on the removal of Cs(+) using a calix crown ether bis(2-propyloxy)calix[4]crown-6 (BPC6) in ionic liquids [C(n)mim][NTf(2)], where [C(n)mim](+) is 1-alkyl-3-methylimidazolium and [NTf(2)](-) is bis(trifluoromethylsulfonyl)imide. The BPC6/[C(n)mim][NTf(2)] system is highly efficient in removing Cs(+) from aqueous solution, even at a low concentration of BPC6. HNO(3) and metal ions such as Na(+), Al(3+) in the aqueous phase interfered with the extraction of Cs(+) by competitive interaction with BPC6 and/or salting-out effect. UV analysis confirmed that the extraction of Cs(+) by the BPC6/[C(n)mim][NTf(2)] system involves a dual extraction mechanism, i.e., via exchange of BPC6.Cs(+) complex or Cs(+) by [C(n)mim](+). Irradiation of [C(4)mim][NTf(2)] dramatically decreases Cs(+) partitioning in the ionic liquid phase by the competitive interaction of radiation-generated H(+) with BPC6, while irradiation of BPC6/[C(4)mim][NTf(2)] decreases Cs(+) partitioning more markedly due to the radiolysis of BPC6.

  3. The influence of constitutional isomerism and change on molecular recognition processes.

    PubMed

    Williams, Avril R; Northrop, Brian H; Houk, Kendall N; Stoddart, J Fraser; Williams, David J

    2004-10-25

    Three constitutionally isomeric bis(naphthylmethyl)ammonium ions, in which the two naphthyl groups are substituted 1) both at their 1-positions, 2) one at its 1-position and the other at its 2-position, and 3) both at their 2-positions, have been investigated separately in solution for their propensities to undergo spontaneous self-assembly with three different [24]crown-8 derivatives, namely, pyrido[24]crown-8 (P24C8), dipyrido[24]crown-8 (DP24C8) and dibenzo[24]crown-8 (DB24C8), in turn to form [2]pseudorotaxanes. The strengths of the 1:1 complexes depend on the composition of the secondary dialkylammonium ions and on the nature of the crown ether hosts; generally, as far as the guest cation is concerned, the 1/1- and 2/2-isomers form stronger complexes, as indicated by stability constant measurements, than the 1/2-isomer and, as far as the crown ethers are concerned, the more flexible P24C8 is a much more efficient host than either DP24C8 or DB24C8. The rates of formation of the [2]pseudorotaxanes are fast (i.e., taking no more than a few minutes) in solution with the exception of one case, that is, in which the crown ether host is DB24C8 and the guest cation is the 1/1-isomer, when it can take upwards of one month for the complexation-decomplexation equilibrium to be established at room temperature. In all cases, the equilibrium between complexed and uncomplexed species is slow on the NMR timescale, allowing the determination of stability constants to be made readily using the single-point method. X-ray crystallography and molecular modeling have been used to gain insight into ground and transition state interactions, respectively, in some of the [2]pseudorotaxanes. The relative stabilities of the three [2]pseudorotaxanes formed by each guest cation in the presence of the three crown ether hosts were also evaluated in solution by competition experiments that were monitored by (1)H NMR spectroscopy. By and large the results of the competition experiments could be predicted on the basis of the derived stability constants for the individual [2]pseudorotaxanes.

  4. Recent Advanced in Rare Earth Chemistry: IREC (International Rare Earth Conference) 85 Held at Zurich (Switzerland) on 4-8 Mar 85.

    DTIC Science & Technology

    1985-06-04

    compounds were employed since 1979. The polyfunc- studied using time-resolved spectro- tlonal ligands (L) included crown ethers scopy, and the...structure of rare earth * Aqueous complexes with cyclic poly - compounds (for example Cs3Ln2X9), was ethers crown ethers , Alstad, Univer- presented by A...Approved for public release; distribution unlimited U.S. Office of Naval Research, London ag - ’ 3 k) I 5.’ - ~1 I 9 ’<I. A -i I. 4. -A kA IS7 ASS

  5. High-throughput and selective solid-phase extraction of urinary catecholamines by crown ether-modified resin composite fiber.

    PubMed

    Chen, LiQin; Wang, Hui; Xu, Zhen; Zhang, QiuYue; Liu, Jia; Shen, Jun; Zhang, WanQi

    2018-08-03

    In the present study, we developed a simple and high-throughput solid phase extraction (SPE) procedure for selective extraction of catecholamines (CAs) in urine samples. The SPE adsorbents were electrospun composite fibers functionalized with 4-carboxybenzo-18-crown-6 ether modified XAD resin and polystyrene, which were packed into 96-well columns and used for high-throughput selective extraction of CAs in healthy human urine samples. Moreover, the extraction efficiency of packed-fiber SPE (PFSPE) was examined by high performance liquid chromatography coupled with fluorescence detector. The parameters affecting the extraction efficiency and impurity removal efficiency were optimized, and good linearity ranging from 0.5 to 400 ng/mL was obtained with a low limit of detection (LOD, 0.2-0.5 ng/mL) and a good repeatability (2.7%-3.7%, n = 6). The extraction recoveries of three CAs ranged from 70.5% to 119.5%. Furthermore, stable and reliable results obtained by the fluorescence detector were superior to those obtained by the electrochemical detector. Collectively, PFSPE coupled with 96-well columns was a simple, rapid, selective, high-throughput and cost-efficient method, and the proposed method could be applied in clinical chemistry. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Magnetic blocking at 10 K and a dipolar-mediated avalanche in salts of the bis(η8-cyclooctatetraenide) complex [Er(COT)2]-.

    PubMed

    Meihaus, Katie R; Long, Jeffrey R

    2013-11-27

    The structures and magnetic properties of [K(18-crown-6)](+) (1) and [K(18-crown-6)(THF)2](+) (2) salts of the η(8)-cyclooctatetraenide sandwich complex [Er(COT)2](-) (COT(2-) = cyclooctatetraene dianion) are reported. Despite slight differences in symmetry, both compounds exhibit slow magnetic relaxation under zero applied dc field with relaxation barriers of ∼150 cm(-1) and waist-restricted magnetic hysteresis. Dc relaxation and dilution studies suggest that the drop in the magnetic hysteresis near zero field is influenced by a bulk magnetic avalanche effect coupled with tunneling of the magnetization. Through dilution with [K(18-crown-6)(THF)2][Y(COT)2] (3), these phenomena are substantially quenched, resulting in an open hysteresis loop to 10 K. Importantly, this represents the highest blocking temperature yet observed for a mononuclear complex and the second highest for any single-molecule magnet. A comprehensive comparative analysis of the magnetism of [K(18-crown-6)][Ln(COT)2] (Ln = Sm, Tb, Dy, Ho, Yb) reveals slow relaxation only for [K(18-crown-6)][Dy(COT)2] (4) with weak temperature dependence. Collectively, these results highlight the utility of an equatorial ligand field for facilitating slow magnetic relaxation in the prolate Er(III) ion.

  7. Interaction between adrenaline and dibenzo-18-crown-6: Electrochemical, nuclear magnetic resonance, and theoretical study

    NASA Astrophysics Data System (ADS)

    Yu, Zhang-Yu; Liu, Tao; Wang, Xue-Liang

    2014-12-01

    The interaction between adrenaline (Ad) and dibenzo-18-crown-6 (DB18C6) was studied by cyclic voltammetry, nuclear magnetic resonance spectroscopy, and the theoretical calculations, respectively. The results show that DB18C6 will affect the electron transfer properties of Ad. DB18C6 can form stable supramolecular complexes with Ad through ion-dipole and hydrogen bond interactions.

  8. Novel crown-ether-methylenediphosphonotetrathioate hybrids as Zn(II) chelators.

    PubMed

    Meltzer, Diana; Gottlieb, Hugo E; Amir, Aviran; Shimon, Linda J W; Fischer, Bilha

    2015-12-28

    Hybrids of methylenediphosphonotetrathioate and crown-ether (MDPT-CE) were synthesized forming 7-,8-,9-,10- and 13-membered rings. Both 7- and 13-membered ring-containing compounds were found to be highly stable to air-oxidation for at least four weeks. These hybrids bind Zn(II) by both MDPT and CE moieties, forming a 2 : 1 L : Zn(II) complex. Interestingly, the 13-membered ring MDPT-CE showing a high affinity to Zn(II) (Ka 3 ± 0.5 × 10(6) mol(-2) L(2)) does not bind Li(I) or Na(I). The 13-Membered MDPT-CE hybrid is a promising water-soluble, air-stable, high-affinity Zn(II)-chelator, exhibiting selectivity to Zn(II) vs. Mg(II), Na(I), and Li(I).

  9. Synthesis, supramolecular behavior, and in vitro photodynamic activities of novel zinc(II) phthalocyanines "side-strapped" with crown ether bridges.

    PubMed

    Chen, Xing-Wei; Ke, Mei-Rong; Li, Xing-Shu; Lan, Wen-Liang; Zhang, Miao-Fen; Huang, Jian-Dong

    2013-12-01

    Two new tetra- or di-α-substituted zinc(II) phthalocyanines 5 and 6 have been prepared through a "side-strapped" method. In the molecules, the adjacent benzene rings of the phthalocyanine core are linked at α-position through a triethylene glycol bridge to form a hybrid aza-/oxa-crown ether. The tetra-α-substituted phthalocyanine 5 shows an eclipsed self-assembly property in CH2Cl2 and the effect on the di-α-substituted analogue 6 is significantly weakened. Furthermore, the crown ethers of these compounds can selectively complex with Fe(3+) or Cu(2+) ion in DMF, leading to formation of J-aggregated nano-assemblies, which can be disaggregated in the presence of some organic or inorganic ligands, such as triethylamine, tetramethylethylenediamine, CH3COO(-), or OH(-). In addition, both compounds are efficient singlet oxygen generators with the singlet oxygen quantum yields (Φ(Δ)) of 0.54-0.74 in DMF relative to unsubstituted zinc(II) phthalocyanine (Φ(Δ)=0.56). They exhibit photodynamic activities toward HepG2 human hepatocarcinoma cells, but the compound 6, which has more than 40-fold lower IC50 value (0.08 μM) compared to the analogue 5 (IC50=3.31 μM), shows remarkablely higher in vitro photocytotoxicity due to its significantly higher cellular uptake and singlet oxygen generation efficiency. The results suggest that these compounds can serve as promising multifunctional materials both in (opto)electronic field and photodynamic therapy. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Variational first hyperpolarizabilities of 2,3-naphtho-15-crown-5 ether derivatives with cation-complexing: a potential and selective cation detector.

    PubMed

    Yu, Hai-Ling; Wang, Wen-Yong; Hong, Bo; Zong, Ying; Si, Yan-Ling; Hu, Zhong-Qiang

    2016-09-29

    Crown ethers, as a kind of heterocycle, have been the subject of great interest over recent decades due to their selective capability to bind to metal cations. The use of a constant crown ether, such as naphtho-15-crown-5 (N15C5), and varied metal cations (Li + , Na + , K + , Be 2+ , Mg 2+ , Ca 2+ , Co 2+ , Ni 2+ , Cu 2+ ) makes it possible to determine the contributions of the metal cations to nonlinear optical (NLO) responses and to design an appropriate NLO-based cation detector. N15C5 and its metal cation derivatives have been systematically investigated by density functional theory. It is found that the dependency of the first hyperpolarizability relies on the metal cation, especially for transition metals. The decrease of the first hyperpolarizabilities for alkali metal cation derivatives is due to their relatively low oscillator strengths, whereas the significant increase of the first hyperpolarizabilities for transition metal cation derivatives can be further illustrated by their low transition energies, large amplitudes and separate distributions of first hyperpolarizability density. Thus, the alkali metal and transition metal cations are distinguishable and the transition metal cations are easier to detect by utilizing the variations in NLO responses.

  11. Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study.

    PubMed

    Jeong, Ii-Do; Kim, Woong-Chul; Park, Jinyoung; Kim, Chong-Myeong; Kim, Ji-Hwan

    2017-08-01

    This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (α=.05). The RMS value of lithium disilicate crown was 29.2 (4.1) µm and 17.6 (5.5) µm on the outer and inner surfaces, respectively, whereas these values were 18.6 (2.0) µm and 20.6 (5.1) µm for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface ( P <.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

  12. Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study

    PubMed Central

    Kim, Chong-Myeong

    2017-01-01

    PURPOSE This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (α=.05). RESULTS The RMS value of lithium disilicate crown was 29.2 (4.1) µm and 17.6 (5.5) µm on the outer and inner surfaces, respectively, whereas these values were 18.6 (2.0) µm and 20.6 (5.1) µm for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns. PMID:28874991

  13. Partial Molar Volumes of 15-Crown-5 Ether in Mixtures of N,N-Dimethylformamide with Water.

    PubMed

    Tyczyńska, Magdalena; Jóźwiak, Małgorzata

    2014-01-01

    The density of 15-crown-5 ether (15C5) solutions in the mixtures of N,N -dimethylformamide (DMF) and water (H 2 O) was measured within the temperature range 293.15-308.15 K using an Anton Paar oscillatory U-tube densimeter. The results were used to calculate the apparent molar volumes ( V Φ ) of 15C5 in the mixtures of DMF + H 2 O over the whole concentration range. Using the apparent molar volumes and Redlich and Mayer equation, the standard partial molar volumes of 15-crown-5 were calculated at infinite dilution ([Formula: see text]). The limiting apparent molar expansibilities ( α ) were also calculated. The data are discussed from the point of view of the effect of concentration changes on interactions in solution.

  14. New polymers for phase partitioning

    NASA Technical Reports Server (NTRS)

    Harris, J. M.

    1981-01-01

    The synthesizing of several polyethylene glycols having crown ethers attached is reported. This work led to the identification of three new polymer types which promise to be more effective at selectively binding specific cell types. Work was completed on identification of chemical properties of the new polymer crowns and on development of new techniques for determination of polymer-phase composition.

  15. Conductivities of the ionic complexes of two cyclic polyethers

    NASA Technical Reports Server (NTRS)

    Fielder, W. L.; Odonnell, P. M.

    1975-01-01

    The conductivities of the solid potassium thiocyanate complex of both dicyclohexyl-18-crown-6 and dibenzo-18-crown-6 were measured at 300K (27 C). Saturated aqueous potassium thiocyanate and graphite were used as ion-transporting and ion-blocking electrodes, respectively. The ionic conductivity predominated for both samples, but it was many orders of magnitude smaller than the value previously reported. The ionic conductivity of the dicyclohexyl complex (the better conductor) was 0.000003 ohm/cm. Crown complexes, in general, do not appear promising as potassium ion solid electrolytes contrary to claims in the patent literature.

  16. Improved selectivity for Pb(II) by sulfur, selenium and tellurium analogues of 1,8-anthraquinone-18-crown-5: synthesis, spectroscopy, X-ray crystallography and computational studies.

    PubMed

    Mariappan, Kadarkaraisamy; Alaparthi, Madhubabu; Hoffman, Mariah; Rama, Myriam Alcantar; Balasubramanian, Vinothini; John, Danielle M; Sykes, Andrew G

    2015-07-14

    We report here a series of heteroatom-substituted macrocycles containing an anthraquinone moiety as a fluorescent signaling unit and a cyclic polyheteroether chain as the receptor. Sulfur, selenium, and tellurium derivatives of 1,8-anthraquinone-18-crown-5 (1) were synthesized by reacting sodium sulfide (Na2S), sodium selenide (Na2Se) and sodium telluride (Na2Te) with 1,8-bis(2-bromoethylethyleneoxy)anthracene-9,10-dione in a 1 : 1 ratio. The optical properties of the new compounds are examined and the sulfur and selenium analogues produce an intense green emission enhancement upon association with Pb(II) in acetonitrile. Selectivity for Pb(II) is markedly improved as compared to the oxygen analogue 1 which was also competitive for Ca(II) ion. UV-Visible and luminescence titrations reveal that 2 and 3 form 1 : 1 complexes with Pb(II), confirmed by single-crystal X-ray studies where Pb(II) is complexed within the macrocycle through coordinate covalent bonds to neighboring carbonyl, ether and heteroether donor atoms. Cyclic voltammetry of 2-8 showed classical, irreversible oxidation potentials for sulfur, selenium and tellurium heteroethers in addition to two one-electron reductions for the anthraquinone carbonyl groups. DFT calculations were also conducted on 1, 2, 3, 6, 6 + Pb(II) and 6 + Mg(II) to determine the trend in energies of the HOMO and the LUMO levels along the series.

  17. Sorption reaction mechanism of some hazardous radionuclides from mixed waste by impregnated crown ether onto polymeric resin.

    PubMed

    Shehata, F A; Attallah, M F; Borai, E H; Hilal, M A; Abo-Aly, M M

    2010-02-01

    A novel impregnated polymeric resin was practically tested as adsorbent material for removal of some hazardous radionuclides from radioactive liquid waste. The applicability for the treatment of low-level liquid radioactive waste was investigated. The material was prepared by loading 4,4'(5')di-t-butylbenzo 18 crown 6 (DtBB18C6) onto poly(acrylamide-acrylic acid-acrylonitril)-N, N'-methylenediacrylamide (P(AM-AA-AN)-DAM). The removal of (134)Cs, (60)Co, (65)Zn , and ((152+154))Eu onto P(AM-AA-AN)-DAM/DtBB18C6 was investigated using a batch equilibrium technique with respect to the pH, contact time, and temperature. Kinetic models are used to determine the rate of sorption and to investigate the mechanism of sorption process. Five kinetics models, pseudo-first-order, pseudo-second-order, intra-particle diffusion, homogeneous particle diffusion (HPDM), and Elovich models, were used to investigate the sorption process. The obtained results of kinetic models predicted that, pseudo-second-order is applicable; the sorption is controlled by particle diffusion mechanism and the process is chemisorption. The obtained values of thermodynamics parameters, DeltaH degrees , DeltaS degrees , and DeltaG degrees indicated that the endothermic nature, increased randomness at the solid/solution interface and the spontaneous nature of the sorption processes. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  18. Synthesis and Characterization of Potassium Aryl- and Alkyl-Substituted Silylchalcogenolate Salts

    DOE PAGES

    Brown, Jessica Lynn; Montgomery, Ashley C.; Samaan, Christopher A.; ...

    2016-02-23

    Treatment of either triphenyl(chloro)silane or tert-butyldiphenyl(chloro)silane with potassium metal in THF, followed by addition of 18-crown-6, affords [K(18-crown-6)][SiPh 3] (1) and [K(18-crown-6)][SiPh 2 tBu] (2), respectively, as the reaction products in high yield. Compounds 1 and 2 were fully characterized including by multi-nuclear NMR and IR spectroscopies. Addition of elemental chalcogen to either 1 or 2, results in facile chalcogen insertion into the potassium-silicon bond to afford the silylchalcogenolates, [K(18-crown-6)][E– SiPh2R] (E = S, R = Ph (3); Se, R = Ph (4); E = Te, R = Ph (5); E = S, R = tBu (6); E = Se,more » R = tBu (7); E = Te, R = tBu (8)), in moderate to good yield. The silylchalcogenolates reported herein were characterized by multi-nuclear NMR and IR spectroscopies, and their solid-state molecular structures were determined by single-crystal X-ray crystallography. Importantly, the reported compounds crystallize as discrete monomers in the solid-state, a structural feature not previously observed in silylchalcogenolates, providing well-defined access routes into systematic metal complexation studies.« less

  19. Effects of strong hydrogen bonds and weak intermolecular interactions on supramolecular assemblies of 4-fluorobenzylamine

    NASA Astrophysics Data System (ADS)

    Wang, Shi; Ding, Xue-Hua; Li, Yong-Hua; Huang, Wei

    2015-07-01

    A series of supramolecular salts have been obtained by the self-assembly of 4-fluorobenzylamine and halide ions or metal chloride with 18-crown-6 as the host in the hydrochloric acid medium, i.e. (C7H9FN)+ṡX- (X = Cl-, 1; Br-, 2), [(C7H9FN)2ṡ(18-crown-6)2]2+ṡ(MCl4)2- (M = Mn, 3; Co, 5; Zn, 7; Cd, 8), [(C7H9FN)ṡ(18-crown-6)]+ṡ(FeCl4)- (4) and [(C7H9FN)ṡ(18-crown-6)]+ṡ1/2(CuCl4)2- (6). Structural analyses indicate that 1-2 crystallize in the triclinic space group P-1, 4 in orthorhombic space group Pnma and 3, 5, 6-8 in the monoclinic space group P21/c or C2/c. In these compounds, extensive intermolecular interactions have been utilized for the self-assembly of diverse supramolecular architectures, ranging from strong N-H⋯X (X = O, Cl, Br) hydrogen bonds to weak C-H⋯Y (Y = F, Cl, π) interactions. N-H⋯Cl/Br hydrogen bonds offer the major driving force in the crystal packing of salts 1-2 while N-H⋯O hydrogen bonds are found in salts 3-8.

  20. Extraction of cesium and strontium from nuclear waste

    DOEpatents

    Davis, Jr., Milton W.; Bowers, Jr., Charles B.

    1988-01-01

    Cesium is extracted from acidified nuclear waste by contacting the waste with a bis 4,4'(5) [1-hydroxy-2-ethylhexyl]benzo 18-crown-6 compound and a cation exchanger in a matrix solution. Strontium is extracted from acidified nuclear waste by contacting the waste with a bis 4,4'(5') [1-hydroxyheptyl]cyclohexo 18-crown-6 compound, and a cation exchanger in a matrix solution.

  1. (18-Crown-6)potassium [(1,2,5,6-η)-cyclo-octa-1,5-diene][(1,2,3,4-η)-naph-tha-lene]-ferrate(-I).

    PubMed

    Brennessel, William W; Ellis, John E

    2012-10-01

    The title salt, [K(C(12)H(24)O(6))][Fe(C(8)H(12))(C(10)H(8))], is the only known naphthalene complex containing iron in a formally negative oxidation state. Each (naphthalene)(1,5-cod)ferrate(-I) anion is in contact with one (18-crown-6)potassium cation via K⋯C contacts to the outer four carbon atoms of the naphthalene ligand (cod = 1,5-cyclo-octa-diene, 18-crown-6 = 1,4,7,10,13,16-hexa-oxacyclo-octa-deca-ne). When using the midpoints of the coordinating olefin bonds, the overall geometry of the coordination sphere around iron can be best described as distorted tetra-hedral. The naphthalene fold angle between the plane of the iron-coordinating butadiene unit and the plane containing the exo-benzene moiety is 19.2 (1)°.

  2. 12-crown-4 ether-assisted enhancement of ionic conductivity and interfacial kinetics in polyethylene oxide electrolytes

    NASA Technical Reports Server (NTRS)

    Nagasubramanian, G.; Di Stefano, S.

    1990-01-01

    The electrical and electrochemical properties of thin films of polyethylene oxide electrolytes with and without 12-crown-4 ether (12Cr4) are studied as a function of temperature and in the frequency regime from 100 kHz to 0.1 Hz. These measurements were made on electrolytes containing LiCF3SO3, LiBF4, or LiClO4 salts. At a given temperature, the bulk conductivity for a particular salt depends on the 12Cr4 concentration, reaching a maximum for a ratio of 12Cr4 to Li of 0.003.

  3. Characterization of the homologs of flerovium with crown ether based extraction chromatography resins: studies in nitric acid

    DOE PAGES

    Despotopulos, John D.; Kmak, Kelly N.; Gharibyan, Narek; ...

    2016-09-17

    Eichrom’s Pb resin, a crown-ether-based extraction chromatography resin, was characterized for separation of the flerovium (Fl) homologs, Pb and Sn. Batch uptake of Pb(II) and Sn(IV) radionuclides was determined from an HNO 3 matrix. Pb(II) was strongly retained on the resin at all HNO 3 concentrations, while Sn(IV) showed no uptake. Extraction kinetics for Pb(II) were examined and show suitable uptake on the second time scale. Here, separation methods for the isolation of individual homologs, Pb(II) and Sn(IV), have been established using 2 mL pre-packed vacuum flow Pb resin columns.

  4. Lanthanide paramagnetic probes for NMR spectroscopic studies of fast molecular conformational dynamics and temperature control. Effective six-site proton exchange in 18-crown-6 by exchange spectroscopy.

    PubMed

    Babailov, Sergey P

    2012-02-06

    (1)H and (13)C NMR measurements are reported for the CDCl(3) and CD(2)Cl(2) solutions of [La(18-crown-6)(NO(3))(3)] (I), [Pr(18-crown-6) (NO(3))(3)] (II), [Ce(18-crown-6)(NO(3))(3)] (III), and [Nd(18-crown-6)(NO(3))(3)] (IV) complexes. Temperature dependencies of the (1)H NMR spectra of paramagnetic II-IV have been analyzed using the dynamic NMR (DNMR) methods for six-site exchange. Two types of conformational dynamic processes were identified (the first one is conditioned by interconversion of complex enantiomeric forms and pseudorotation of a macrocycle molecule upon the C(2) symmetry axis; the second one is conditioned by macrocycle molecule inversion). Application of exchange spectroscopy (2D-EXSY) of DNMR for investigation of this dynamic system (II-IV) simplifies the assignment of the NMR signals and represents the first experimental study of multisite exchange. In the present work, the methodology of paramagnetic 4f (Ce, Pr, and Nd) probe applications for the study of free-energy, enthalpy, and entropy changes in chemical exchange processes, as well as the advantages of this method in a comparison with DNMR studies of diamagnetic substances, is discussed. In particular, as a result of paramagnetic chemical shifts in 4f complexes, the range of measurable rate constants expands considerably compared to the analogous range in diamagnetic compounds. Coordination compounds investigated in the paper represent new types of thermometric NMR sensors and lanthanide paramagnetic probes for in situ temperature control in solution.

  5. Assessment of oral hygiene and periodontal health around posterior primary molars after their restoration with various crown types.

    PubMed

    Beldüz Kara, Nihal; Yilmaz, Yucel

    2014-07-01

    To compare the time-dependent changes in oral hygiene and periodontal health after restoring primary posterior molars with a traditional stainless steel crown (SSC) or an aesthetic crown using various measures of periodontal health and oral hygiene. This investigation was a randomized, non-blinded prospective controlled clinical trial in which 264 crowns of different types were fitted onto the first and/or second primary molars of 76 children. The oral hygiene and the gingival health of the restored teeth and the antagonistic teeth were evaluated clinically and radiographically at 3- and 6-month intervals for 18 months after fitting the crowns. The periodontal health of the control teeth was better than that of the remaining 215 restored teeth. The oral hygiene, as measured by the simplified oral hygiene index, and gingival health, as measured by the gingival index and the volume of gingival crevicular fluid, of the restored teeth, irrespective of crown type, progressively increased during the 18-month study period. Oral hygiene and gingival health around a restored primary tooth deteriorate with time. Our results suggest that SSC, an open-faced SSC, or a NuSmile(®) pediatric crown should be the preferred crown type for restoring posterior primary teeth. © 2013 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Octoxy capped Si nanoparticles synthesized by homogeneous reduction of SiCl4 with crown ether alkalide.

    PubMed

    Sletnes, M; Maria, J; Grande, T; Lindgren, M; Einarsrud, M-A

    2014-02-07

    Blue-green luminescent octoxy capped Si nanoparticles were synthesized via homogeneous reduction of SiCl4 with the crown ether alkalide K(+)(15-crown-5)2K(-) in tetrahydrofuran. The Si nanoparticles were characterized with respect to size, crystal structure, morphology, surface termination, optical properties and stability. Si diamond structure nanoparticles with narrow size distributions, and average diameters ranging from 3 to 7 nm were obtained. A finite-size effect on the lattice dimensions was observed, in the form of an expansion of the [220] lattice planes of smaller Si nanoparticles. The concentration of SiCl4 was found to be the most important parameter governing the particle size and size distribution. The octoxy capped particles were stable under an ambient atmosphere for at least one month, but exposure to water made them prone to oxidation. An average radiative recombination lifetime of 8.8 ns was measured for the blue-green luminescence. The luminescence appears to originate from surface defects, rather than from quantum confinement.

  7. Absorption and biotransformation of polybrominated diphenyl ethers DE-71 and DE-79 in chicken (Gallus gallus), mallard (Anas platyrhynchos), American kestrel (Falco sparverius) and black-crowned night-heron (Nycticorax nycticorax) eggs

    USGS Publications Warehouse

    McKernan, Moira A.; Rattner, Barnett A.; Hatfield, Jeff S.; Hale, Robert C.; Ottinger, Mary Ann

    2010-01-01

    We recently reported that air cell administration of penta-brominated diphenyl ether (penta-BDE; DE-71) evokes biochemical and immunologic effects in chicken (Gallus gallus) embryos at very low doses, and impairs pipping (i.e., stage immediately prior to hatching) and hatching success at 1.8 ug g-1 egg (actual dose absorbed) in American kestrels (Falco sparverius). I n the present study, absorption of polybrominated diphenyl ether (PBDE) congeners was measured following air cell administration of a penta-BDE mixture (11.1 ug DE-71 g-1 egg) or an octa-brominated diphenyl ether mixture (octa-BDE; DE-79; 15.4 ug DE-79 g-1 egg). Uptake of PBDE congeners was measured at 24 h post-injection, midway through incubation, and at pipping in chicken, mallard (Anas platyrhynchos), and American kestrel egg contents, and at the end of incubation in black-crowned night-heron (Nycticorax nycticorax) egg contents. Absorption of penta-BDE and octa-BDE from the air cell into egg contents occurred throughout incubation; at pipping, up to 29.6% of penta-BDE was absorbed, but only 1.40-6.48% of octa-BDE was absorbed. Higher brominated congeners appeared to be absorbed more slowly than lower brominated congeners, and uptake rate was inversely proportional to the log Kow of predominant BDE congeners. Six congeners or co-eluting pairs of congeners were detected in penta-BDE-treated eggs that were not found in the dosing solution suggesting debromination in the developing embryo, extraembryonic membranes, and possibly even in the air cell membrane. This study demonstrates the importance of determining the fraction of xenobiotic absorbed into the egg following air cell administration for estimation of the lowest-observed-effect level.

  8. Effect of ionophores on the rate of intramolecular cation exchange in durosemiquinone ion pairs

    NASA Technical Reports Server (NTRS)

    Eastman, M. P.; Bruno, G. V.; Mcguyer, C. A.; Gutierrez, A. R.; Shannon, J. M.

    1979-01-01

    The effects of the ionophores 15-crown-5 (15C5), 18-crown-6 (18C6), dibenzo-18-crown-6 (DBC) and cryptand 222 (C222) on intramolecular cation exchange in ion pairs of the sodium salt of the durosemiquinone anion in benzene solution are investigated. Electron paramagnetic resonance spectra of the 18C6 and 15C5 complexes with durosemiquinone reduced by contact with a sodium mirror show an alternating line width which indicates that the sodium ion is being exchanged between equivalent sites near the oxygens of the semiquinone with activation energies of 8.7 and 6.0 kcal/mole and Arrhenius preexponential factors of 9 x 10 to the 12th/sec and 10 to the 12th/sec, respectively. Spectra obtained for the DBC complexes show no evidence of exchange, while those of C222 indicate rapid exchange. It is also noted that the hyperfine splitting constants measured do not change over the 50-K temperature interval studied.

  9. Extraction of cesium and strontium from nuclear waste

    DOEpatents

    Davis, M.W. Jr.; Bowers, C.B. Jr.

    1988-06-07

    Cesium is extracted from acidified nuclear waste by contacting the waste with a bis 4,4[prime](5) [1-hydroxy-2-ethylhexyl]benzo 18-crown-6 compound and a cation exchanger in a matrix solution. Strontium is extracted from acidified nuclear waste by contacting the waste with a bis 4,4[prime](5[prime]) [1-hydroxyheptyl]cyclohexo 18-crown-6 compound, and a cation exchanger in a matrix solution. 3 figs.

  10. Quantization of bovine serum albumin by fluorescence enhancement effects and corresponding binding of macrocyclic host-protein assembly.

    PubMed

    Bardhan, Munmun; Misra, Tapas; Ganguly, Tapan

    2012-01-05

    The present paper reports the investigations on the spectroscopic behavior of the binary complexes of the dye aurintricarboxylic acid (ATA) with protein bovine serum albumin (BSA) and 18-crown 6 (CW) (ATA·BSA, ATA·CW) and the ternary complex ATA·CW·BSA by using UV-vis steady state and time resolved fluorescence spectroscopy. The primary aim of the work is to determine the protein (BSA) quantization by fluorescence enhancement method and investigate the 'enhancer' activity of crown ether (CW) on it to increase the resolution. Steady state and time resolved fluorescence measurements demonstrated how fluorescence intensity of ATA could be used for the determination of the protein BSA in aqueous solution. The binding of dye (probe/fluorescent medicinal molecule) with protein and the denaturing effect in the polar environment of acetonitrile of the dye protein complex act as drug binding as well as drug release activity. Apart from its basic research point of view, the present study also possesses significant importance and applications in the field of medicinal chemistry. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Supramolecular Recognition Allows Remote, Site-Selective C-H Oxidation of Methylenic Sites in Linear Amines.

    PubMed

    Olivo, Giorgio; Farinelli, Giulio; Barbieri, Alessia; Lanzalunga, Osvaldo; Di Stefano, Stefano; Costas, Miquel

    2017-12-18

    Site-selective C-H functionalization of aliphatic alkyl chains is a longstanding challenge in oxidation catalysis, given the comparable relative reactivity of the different methylenes. A supramolecular, bioinspired approach is described to address this challenge. A Mn complex able to catalyze C(sp 3 )-H hydroxylation with H 2 O 2 is equipped with 18-benzocrown-6 ether receptors that bind ammonium substrates via hydrogen bonding. Reversible pre-association of protonated primary aliphatic amines with the crown ether selectively exposes remote positions (C8 and C9) to the oxidizing unit, resulting in a site-selective oxidation. Remarkably, such control of selectivity retains its efficiency for a whole series of linear amines, overriding the intrinsic reactivity of C-H bonds, no matter the chain length. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Ligand reprogramming in dinuclear helicate complexes: a consequence of allosteric or electrostatic effects?

    PubMed

    Jeffery, John C; Rice, Craig R; Harding, Lindsay P; Baylies, Christian J; Riis-Johannessen, Thomas

    2007-01-01

    The ditopic ligand 6,6'-bis(4-methylthiazol-2-yl)-3,3'-([18]crown-6)-2,2'-bipyridine (L(1)) contains both a potentially tetradentate pyridyl-thiazole (py-tz) N-donor chain and an additional "external" crown ether binding site which spans the central 2,2'-bipyridine unit. In polar solvents (MeCN, MeNO(2)) this ligand forms complexes with Zn(II), Cd(II), Hg(II) and Cu(I) ions via coordination of the N donors to the metal ion. Reaction with both Hg(II) and Cu(I) ions results in the self-assembly of dinuclear double-stranded helicate complexes. The ligands are partitioned by rotation about the central py--py bond, such that each can coordinate to both metals as a bis-bidentate donor ligand. With Zn(II) ions a single-stranded mononuclear species is formed in which one ligand coordinates the metal ion in a planar tetradentate fashion. Reaction with Cd(II) ions gives rise to an equilibrium between both the dinuclear double-stranded helicate and the mononuclear species. These complexes can further coordinate s-block metal cations via the remote crown ether O-donor domains; a consequence of which are some remarkable changes in the binding modes of the N-donor domains. Reaction of the Hg(II)- or Cd(II)-containing helicate with either Ba(2+) or Sr(2+) ions effectively reprogrammes the ligand to form only the single-stranded heterobinuclear complexes [MM'(L(1))](4+) (M=Hg(II), Cd(II); M'=Ba(2+), Sr(2+)), where the transition and s-block cations reside in the N- and O-donor sites, respectively. In contrast, the same ions have only a minor structural impact on the Zn(II) species, which already exists as a single-stranded mononuclear complex. Similar reactions with the Cd(II) system result in a shift in equilibrium towards the single-stranded species, the extent of which depends on the size and charge of the s-block cation in question. Reaction of the dicopper(I) double-stranded helicate with Ba(2+) shows that the dinuclear structure still remains intact but the pitch length is significantly increased.

  13. Revisiting the Formation and Tunable Dissociation of a [2]Pseudorotaxane Formed by Slippage Approach

    PubMed Central

    Leung, Ken Cham-Fai; Lau, Kwun-Ngai; Wong, Wing-Yan

    2015-01-01

    A new [2]pseudorotaxane DB24C8⊃1-H·PF6 with dibenzo[24]crown-8 (DB24C8) crown ether-dibenzylammonium (1-H·PF6) binding which was formed by slippage approach at different solvents and temperature, had been isolated and characterized by NMR spectroscopy and mass spectrometry. The [2]pseudorotaxane DB24C8⊃1-H·PF6 was stable at room temperature. The dissociation rate of [2]pseudorotaxane DB24C8⊃1-H·PF6 could be tuned by using different stimuli such as triethylamine (TEA)/diisopropylethylamine (DIPEA) and dimethyl sulfoxide (DMSO). In particular, the dissociation of [2]pseudorotaxane DB24C8⊃1-H·PF6 by an excess of TEA/DIPEA base mixture possessed a long and sustained, complete dissociation over 60 days. Other stimuli by DMSO possessed a relatively fast dissociation over 24 h. PMID:25872145

  14. (18-Crown-6)potassium [(1,2,5,6-η)-cyclo­octa-1,5-diene][(1,2,3,4-η)-naph­tha­lene]­ferrate(−I)

    PubMed Central

    Brennessel, William W.; Ellis, John E.

    2012-01-01

    The title salt, [K(C12H24O6)][Fe(C8H12)(C10H8)], is the only known naphthalene complex containing iron in a formally negative oxidation state. Each (naphthalene)(1,5-cod)ferrate(−I) anion is in contact with one (18-crown-6)potassium cation via K⋯C contacts to the outer four carbon atoms of the naphthalene ligand (cod = 1,5-cyclo­octa­diene, 18-crown-6 = 1,4,7,10,13,16-hexa­oxacyclo­octa­deca­ne). When using the midpoints of the coordinating olefin bonds, the overall geometry of the coordination sphere around iron can be best described as distorted tetra­hedral. The naphthalene fold angle between the plane of the iron-coordinating butadiene unit and the plane containing the exo-benzene moiety is 19.2 (1)°. PMID:23125569

  15. Aza compounds as anion receptors

    DOEpatents

    Lee, H.S.; Yang, X.Q.; McBreen, J.

    1998-01-06

    A family of aza-ether based compounds including linear, multi-branched and aza-crown ethers is provided. When added to non-aqueous battery electrolytes, the family of aza-ether based compounds acts as neutral receptors to complex the anion moiety of the electrolyte salt thereby increasing the conductivity and the transference number of Li{sup +} ion in alkali metal batteries. 3 figs.

  16. Aza compounds as anion receptors

    DOEpatents

    Lee, Hung Sui; Yang, Xiao-Qing; McBreen, James

    1998-01-06

    A family of aza-ether based compounds including linear, multi-branched and aza-crown ethers is provided. When added to non-aqueous battery electrolytes, the family of aza-ether based compounds acts as neutral receptors to complex the anion moiety of the electrolyte salt thereby increasing the conductivity and the transference number of Li.sup.+ ion in alkali metal batteries.

  17. On the radiation stability of crown ethers in ionic liquids.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shkrob, I.; Marin, T.; Dietz, M.

    2011-04-14

    Crown ethers (CEs) are macrocyclic ionophores used for the separation of strontium-90 from acidic nuclear waste streams. Room temperature ionic liquids (ILs) are presently being considered as replacements for traditional molecular solvents employed in such separations. It is desirable that the extraction efficacy obtained with such solvents should not deteriorate in the strong radiation fields generated by decaying radionuclides. This deterioration will depend on the extent of radiation damage to both the IL solvent and the CE solute. While radiation damage to ILs has been extensively studied, the issue of the radiation stability of crown ethers, particularly in an ILmore » matrix, has not been adequately addressed. With this in mind, we have employed electron paramagnetic resonance (EPR) spectroscopy to study the formation of CE-related radicals in the radiolysis of selected CEs in ILs incorporating aromatic (imidazolium and pyridinium) cations. The crown ethers have been found to yield primarily hydrogen loss radicals, H atoms, and the formyl radical. In the low-dose regime, the relative yield of these radicals increases linearly with the mole fraction of the solute, suggesting negligible transfer of the excitation energy from the solvent to the solute; that is, the solvent has a 'radioprotective' effect. The damage to the CE in the loading region of practical interest is relatively low. Under such conditions, the main chemical pathway leading to decreased extraction performance is protonation of the macrocycle. At high radiation doses, sufficient to increase the acidity of the IL solvent significantly, such proton complexes compete with the solvent cations as electron traps. In this regime, the CEs will rapidly degrade as the result of H abstraction from the CE ring by the released H atoms. Thus, the radiation dose to which a CE/IL system is exposed must be maintained at a level sufficiently low to avoid this regime.« less

  18. Determination of ammonium in wastewaters by capillary electrophoresis on a column-coupling chip with conductivity detection.

    PubMed

    Luc, Milan; Kruk, Pavol; Masár, Marián

    2011-07-01

    Analytical potentialities of a chip-based CE in determination of ammonium in wastewaters were investigated. CZE with the electric field and/or ITP sample stacking was performed on a column-coupling (CC) chip with integrated conductivity detectors. Acetate background electrolytes (pH ∼3) including 18-crown-6-ether (18-crown-6) and tartaric acid were developed to reach rapid (in 7-8 min) CZE and ITP-CZE resolutions of ammonium from other cations (sodium, potassium, calcium and magnesium) present in wastewater samples. Under preferred working conditions (suppressed hydrodynamic flow (HDF) and EOF on the column-coupling chip), both the employed methods did provide very good repeatabilities of the migration (RSD of 0.2-0.8% for the migration time) and quantitative (RSD of 0.3-4.9% for the peak area) parameters in the model and wastewater samples. Using a 900-nL sample injection volume, LOD for ammonium were obtained at 20 and 40 μg/L concentrations in CZE and ITP-CZE separations, respectively. Very good agreements of the CZE and ITP-CZE determinations of ammonium in six untreated wastewater samples (only filtration and dilution) with the results obtained by a reference spectrometric method indicate a very good accuracy of both the CE methods presented. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Polynuclear Hydroxido-Bridged Complexes of Platinum(IV) with Terminal Nitrato Ligands.

    PubMed

    Vasilchenko, Danila; Berdugin, Semen; Tkachev, Sergey; Baidina, Iraida; Romanenko, Galina; Gerasko, Olga; Korenev, Sergey

    2015-05-18

    For the first time the polynuclear hydroxido-bridged platinum(IV) nitrato complexes with nuclearity higher than two were isolated from nitric acid solutions of [Pt(H2O)2(OH)4] and crystallized as supramolecular compounds of macrocyclic cavitands cucurbit[n]uril (CB[n], n = 6,8) and 18-crown-6 ether: [Pt4(μ3-OH)2(μ2-OH)4(NO3)10]·CB[6]·25H2O (I), [Pt6(μ3-OH)4(μ2-OH)6(NO3)12](NO3)2·CB[8]·50H2O (II), and [H3O⊂18-crown-6]2[Pt2(μ2-OH)2(NO3)8][Pt4(μ3-OH)2(μ2-OH)4(NO3)10] (III). The isolation of the compounds in the single crystalline state allows the determination of the structure of the tetranuclear and hexanuclear complexes [Pt4(μ3-OH)2(μ2-OH)4(NO3)10] and [Pt6(μ3-OH)4(μ2-OH)6(NO3)12](2+), which have been previously unknown in the solid state. Stability of Ptx(OH)y cores of the polynuclear nitrato complexes toward alkaline hydrolysis was verified by (195)Pt NMR spectroscopy. Analysis of (195)Pt NMR spectra of the compound III reveals that addition of every Pt(μ-OH)2Pt ring results in ∼260 ppm downfield shift relative to the mononuclear form, which allows the prediction of signal positions for complexes of higher nuclearity.

  20. Complexation of imidazopyridine-based cations with a 24-crown-8 ether host: [2]pseudorotaxane and partially threaded structures.

    PubMed

    Moreno-Olivares, Surisadai I; Cervantes, Ruy; Tiburcio, Jorge

    2013-11-01

    A new series of linear molecules derived from 1,2-bis(imidazopyridin-2-yl)ethane can fully or partially penetrate the cavity of the dibenzo-24-crown-8 macrocycle to produce a new family of host-guest complexes. Protonation or alkylation of the nitrogen atoms on the pyridine rings led to an increase in the guest total positive charge up to 4+ and simultaneously generated two new recognition sites (pyridinium motifs) that are in competition with the 1,2-bis(benzimidazole)ethane motif for the crown ether. The relative position of the pyridine ring and the chemical nature of the N-substituent determined the preferred motif and the host-guest complex geometry: (i) for linear guests with relatively bulky groups (i.e., a benzyl substituent), the 1,2-bis(benzimidazole)ethane motif is favored, leading to a fully threaded complex with a [2]pseudorotaxane geometry; (ii) for small substituents, such as -H and -CH3 groups, regardless of the guest shape, the pyridinium motifs are preferred, leading to external partially threaded complexes in a 2:1 host to guest stoichiometry.

  1. Anion receptor compounds for non-aqueous electrolytes

    DOEpatents

    Lee, Hung Sui; Yang, Xiao-Oing; McBreen, James

    2000-09-19

    A new family of aza-ether based compounds including linear, multi-branched and aza-crown ethers is provided. When added to non-aqueous battery electrolytes, the new family of aza-ether based compounds acts as neutral receptors to complex the anion moiety of the electrolyte salt thereby increasing the conductivity and the transference number of LI.sup.+ ion in alkali metal batteries.

  2. A Reliable Hybrid Adsorbent for Efficient Radioactive Cesium Accumulation from Contaminated Wastewater

    PubMed Central

    Awual, Md. Rabiul; Yaita, Tsuyoshi; Miyazaki, Yuji; Matsumura, Daiju; Shiwaku, Hideaki; Taguchi, Tomitsugu

    2016-01-01

    Cesium (Cs) removal from nuclear liquid wastewater has become an emerging issue for safeguarding public health after the accident at the Fukushima Daiichi Nuclear Power Plant. A novel macrocyclic ligand of o-benzo-p-xylyl-22-crown-6-ether (OBPX22C6) was developed and successfully immobilized onto mesoporous silica for the preparation of hybrid adsorbent. The benzene ring π electron is the part of crown ether of OBPX22C6 for easy orientation of the macrocyclic compound for making the π electron donation with Cs complexation. The potential and feasibility of the hybrid adsorbent as being Cs selective was evaluated in terms of sensitivity, selectivity and reusability. The results clarified that the Cs removal process was rapid and reached saturation within a short time. Considering the effect of competitive ions, sodium (Na) did not markedly affect the Cs adsorption whereas potassium (K) was slightly affected due to the similar ionic radii. However, the oxygen in long ethylene glycol chain in OBPX22C6 was expected to show strong coordination, including Cs-π interaction with Cs even in the presence of the high amount of K and Na. Due to its high selectivity and reusability, significant volume reduction is expected as this promising hybrid adsorbent is used for Cs removal in Fukushima wastewater. PMID:26818070

  3. A Reliable Hybrid Adsorbent for Efficient Radioactive Cesium Accumulation from Contaminated Wastewater.

    PubMed

    Awual, Md Rabiul; Yaita, Tsuyoshi; Miyazaki, Yuji; Matsumura, Daiju; Shiwaku, Hideaki; Taguchi, Tomitsugu

    2016-01-28

    Cesium (Cs) removal from nuclear liquid wastewater has become an emerging issue for safeguarding public health after the accident at the Fukushima Daiichi Nuclear Power Plant. A novel macrocyclic ligand of o-benzo-p-xylyl-22-crown-6-ether (OBPX22C6) was developed and successfully immobilized onto mesoporous silica for the preparation of hybrid adsorbent. The benzene ring π electron is the part of crown ether of OBPX22C6 for easy orientation of the macrocyclic compound for making the π electron donation with Cs complexation. The potential and feasibility of the hybrid adsorbent as being Cs selective was evaluated in terms of sensitivity, selectivity and reusability. The results clarified that the Cs removal process was rapid and reached saturation within a short time. Considering the effect of competitive ions, sodium (Na) did not markedly affect the Cs adsorption whereas potassium (K) was slightly affected due to the similar ionic radii. However, the oxygen in long ethylene glycol chain in OBPX22C6 was expected to show strong coordination, including Cs-π interaction with Cs even in the presence of the high amount of K and Na. Due to its high selectivity and reusability, significant volume reduction is expected as this promising hybrid adsorbent is used for Cs removal in Fukushima wastewater.

  4. Anisotropic dielectric phase transition triggered by pendulum-like motion coupled with proton transfer in a layered hybrid crystalline material (4-nitroanilinium+) (18-crown-6) (H2PO4-) (H3PO4)2

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Zhu, Chun-li; Qin, Liu-lei; Zheng, Xiao-yuan; Liu, Zun-qi

    2018-07-01

    The organic-inorganic hybrid phase-transition material, (4-nitroanilinium+) (18-crown-6) (H2PO4-) (H3PO4)2 (1), was successfully synthesized. The organic (4-nitroanilinium) (18-crown-6)+ supramolecular cation layer and inorganic phosphate anion layer were arranged alternately. Differential scanning calorimetry (DSC), temperature-dependent dielectric measurements, and variable-temperature single-crystal X-ray diffraction analysis confirmed the reversible isostructural phase transition of 1 with the same space group Pbca at 225 K, wherein the synergistic effect between the pendulum-like motion of organic cations and the proton transfer in the Osbnd H⋯O hydrogen bonding of inorganic anions was mainly responsible for the phase-transition behavior of 1. The most striking dielectric property was the remarkable anisotropy along various crystallographic axes. A potential-energy calculation further supported the possibility of dynamic motion of cations in the crystal.

  5. Asymmetric Synthesis of Secondary and Tertiary Propargylic Alcohols by Umpolung of Acetylenic Sulfones and ortho-Sulfinyl Carbanions.

    PubMed

    Rodríguez, Ricardo I; Ramírez, Elsie; Yuste, Francisco; Sánchez-Obregón, Rubén; Alemán, José

    2018-02-16

    The generation of diastereomerically enriched secondary benzyl propargyl alcohols by the asymmetric addition of ortho-sulfinylbenzyl carbanions to sulfonylacetylene derivatives via formation of a Csp-Csp 3 bond is described. This reaction proceeds through an unusual α-attack (anti-Michael addition) of the ortho-sulfinylbenzyl carbanions, followed by elimination of the arylsulfonyl moiety. The scope of this alkynylation reaction is also discussed. Moreover, the development of a new approach for the synthesis of optically active tertiary benzylpropargyl alcohols is described, discussing the possible stereocourse of the reaction so as the influence of the ether 18-crown-6 and steric importance of acetylenic substituent.

  6. Macrocycles inserted in graphene: from coordination chemistry on graphene to graphitic carbon oxide.

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Liu, Jingyao; Miao, Maosheng

    Tuning the electronic structure and the chemical properties of graphene by binding with metals has become a focus in the area of two dimension materials. Despite many interesting results and promising potentials, the approach suffers from weak binding and the high reactivity of the metal atoms. On the other hand, many macrocyclic molecules such as crown ether show strong and selective binding with metal atoms. The alliance of the two substances will largely benefit the two parallel fields: it will provide a scaffold for coordination chemistry as well as a controllable method for tuning the electronic structure of graphene through strong binding with metals. Here, using crown ether as an example, we demonstrate by first principles calculations that the embedment of macrocyclic molecules into graphene honeycomb lattice can be very thermochemically favored. The embedment of crown ether on graphene can form a family of new two-dimensional materials that possess varying band gaps and band edges. The one with highest O composition (C2O), with similar structure features as graphilic C3N4, shows strong potentials for photolysis and as true two-dimensional superconductor while binding with alkali metals. Calculations are performed on NSF-funded XSEDE resources (TG-DMR130005). This research is also supported by National Natural Science Foundation of China (Grants No. 21373098) in China.

  7. Practice-based clinical evaluation of ceramic single crowns after at least five years.

    PubMed

    Dhima, Matilda; Paulusova, Vladimira; Carr, Alan B; Rieck, Kevin L; Lohse, Christine; Salinas, Thomas J

    2014-02-01

    Long-term practice-based clinical evaluations of various contemporary ceramic crown restorations from multiple practitioners are limited. The aims of this study were to evaluate the clinical performance of ceramic single crowns and to identify factors that influence their clinical performance. Ceramic single crowns that had been placed at the Mayo Clinic and in function since 2005 were identified and included in the study. The restorations were examined clinically, radiographically, and with photographs. Modified United States Public Health Services criteria were used for the clinical evaluation. The ceramic systems evaluated were bilayer and monolayer. Fifty-nine patients (41 women, 18 men) with 226 single teeth and implants restored with single ceramic crowns were identified. The mean duration from insertion date to study examination date was 6.1 years. Thirteen restorations (6%) were replaced at a mean 3.3 years after insertion date (range, 0.1-6.1 years). Estimated replacement-free survival rates (95% confidence interval [CI]; number of teeth/implants still at risk) at 5 years after insertion date were 95.1% (95% CI, 92.2-98.1; 153) and at 10 years were 92.8% (95% CI, 89.1-96.8; 8). The most common reason for replacement was fracture to the core of posterior layered ceramic crowns. The most commonly used luting agent was resin-modified ionomer cement. Most restorations exhibited clinically acceptable marginal integrity, shade, no caries recurrence, and no periapical pathology. The clinical performance of ceramic single crowns at 5 and 10 years supports their application in all areas of the mouth. With the majority of fractures to the core occurring early in the lifetime of layered ceramic posterior crowns, consideration of other monolithic ceramic systems for posterior crowns is advised. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  8. Enantiomeric Recognition of Organic Ammonium Salts by Chiral Dialkyl-, Dialkenyl-, and Tetramethyl-Substituted Pyridino-18-Crown-6 and Tetramethyl- Substituted Bis-Pyridino-18-Crown-6 Ligands: Comparison of Temperature-Dependent 1H NMR and Empirical Force Field Techniques

    DTIC Science & Technology

    1990-04-18

    COVERED 14, DATE OF REPORT (Year. Month, Day) 15. PAGE COUNT Interim FROM _ _ TO April 18, 1990 16. SUPPLEMENTARY NOTATION 17 , COSATI CODES 18. SUBJECT...to epoxide 17 was carried out ,o by using the method of Koppenhoefer and Schurig.241-2 Our epoxides 17 where R was isopropyl, isobutyl, and Scheme i... 17 with diethylene glycol and a catalytic amount of sodium was carried out as reported for the preparation of the chiral dimethyl- tetraethylene glycol

  9. [Crown color match of implant-supported zirconia and porcelain-fused-to-metal restorations: a spectrophotometric comparison].

    PubMed

    Peng, Min; Fei, Wei; Hosseini, Mandana; Gotfredsen, Klaus

    2014-02-01

    This study aimed to compare the crown color match of implant-supported zirconia restorations and porcelain-fused-to-metal (PFM) restorations in the anterior maxillary region through spectrophotometric evaluation. Eighteen patients with 29 implant-supported single crowns in the anterior maxillary area were recruited. Eleven of the implant crowns were zirconia restorations and 18 were PFM restorations. Color matching of the implant crown with contra-lateral/ neighboring tooth at the position of body 1/3 of the crown was assessed using a spectrophotometer (SpectroShade) in CIE L* a* b* coordinates. Subjective crown color match scores were evaluated. Independent sample t test of SPSS 17.0 was used to compare the difference between zirconia restoration and PFM restoration. Spearman correlation was used to analyze the relationship between the spectrophotometric color difference and the subjective crown color match score. Descriptive statistics was used to analyze the distribution of color coordinates of natural anterial teeth. The crown color of the implant-supported zirconia restorations and PFM restorations were both lighter than that of natural teeth (delta L, 4.5 +/- 3.2, 1.0 +/- 2.6). The lightness difference induced by zirconia restorations was significantly larger than that induced by PFM restorations (P=0.004). The spectrophotometric crown color difference (delta E) induced by zirconia restorations (7.0 +/- 2.8) was significantly larger than that induced by PFM restorations (4.0 +/- 1.9) (P=0.002), and both values were beyond the clinical thresholds (3.7). The spectrophotometric crown color difference induced by zirconia restorations was significantly larger than that induced by PFM restorations. However, they were indistinguishable in subjective evaluation.

  10. Fast Potentiometric Analysis of Lead in Aqueous Medium under Competitive Conditions Using an Acridono-Crown Ether Neutral Ionophore.

    PubMed

    Golcs, Ádám; Horváth, Viola; Huszthy, Péter; Tóth, Tünde

    2018-05-03

    Lead is a particularly toxic heavy metal that is present above acceptable levels in the water of many countries. This article describes a quick detection method of lead(II) ions using a polyvinyl chloride (PVC)-based ion-selective membrane electrode containing an acridono-crown ether ionophore by potentiometry. The electrochemical cell exhibits a Nernstian response for lead(II) ions between the concentration range of 10 −4 to 10 −2 M, and can be used in the pH range of 4⁻7. The applicability of this sensor was verified by measuring a multicomponent aqueous sample. Under the given conditions, this electrode is suitable for the selective quantitative analysis of lead(II) ions in the presence of many additional metal ions.

  11. Novel benzo-15-crown-5 sol-gel coating for solid-phase microextraction.

    PubMed

    Wang, Danhua; Xing, Jun; Peng, Jiagang; Wu, Caiying

    2003-07-11

    A novel dihydroxy-terminated benzo-15-crown-5 was synthesized and applied to prepare a solid-phase microextraction (SPME) fiber coating with sol-gel technology. The optimization of the sol-gel process was studied. The coating method with sol-gel was improved and completed in one run, which economized materials and allowed easier control of the fiber thickness. The repeatability of coating fiber to fiber was better than 4.94% (RSD). The surface of the fiber coating was well-distributed and an electron microscopy experiment suggested a porous structure for crown ether coating, providing high surface areas and allowing for high extraction efficiency. The coating has a high thermal stability (350 degrees C), long lifetime and can stand solvent (organic and inorganic) rinsing due to the chemical binding between the coating and the fiber surface. Non-polar benzene, toluene, ethylbenzene, xylenes, chlorobenzenes, polar phenolic compounds and arylamines were used to evaluate the character of the fiber coating by headspace SPME-gas chromatography technology. For phenols, the linear concentrations ranged from 5 to 1000 microg/l, the detection limits were between 0.05 and 1 microg/l, and the RSD was less than 5%. The addition of benzo-crown ether not only increases the thermal stability of the fiber coating, but also enhances the selectivity of the fiber coating. Compared with commercially available SPME fibers poly(dimethylsiloxane) and polyacrylate, the few phases showed better selectivity and sensitivity towards non-polar and polar aromatic compounds.

  12. Growth trends in pruned red spruce trees

    Treesearch

    Barton M. Blum; Dale S. Solomon

    1980-01-01

    The diameter growth of red spruce with 1/6, 1/3, and 1/2 crown removed was compared with that of unpruned trees for 18 growing seasons. Although removal of 1/6 of the live crown did not adversely affect annual radial growth, compared with that of the controls, removal of 1/3 and 1/2 had a significant effect on the cumulative radial growth for 2 and 9 growing seasons,...

  13. Thermodynamic and NMR Studies of Solvent Effect on Enantiomeric Recognition for a Chiral Organiz Ammonium Cation by Chiral Diketopyridino-18- Crown-6 Type Ligands at 25.0 deg C.

    DTIC Science & Technology

    1994-05-11

    analyses, 1H NM&, and JR specPit oscopy. The purities were also determined quantitatively by a thermometric titration technique. 19 By titrting...enantiomers of NapEt with 18- crown-6 (SIGMA Chemical Company, its purity was 99.5% as determined by therm--ometric titration agtains a standard NaBr...isoperibol titration calorimetry at 25.0 - 0.1oC in CACi6CHOH solvent mixtures. The initial solution volume in the dewar was 20 mL Tne calorimeter (wac

  14. Cation or Solvent-Induced Supermolecular Phthalocyanine Formation: Crown Ether Substituted Phthalocyanines.

    DTIC Science & Technology

    1987-06-01

    38.) of slightly bluish green powder (Anal, see Table I). tH NMR(CDCl 3 ) 8.02(8H,s), 4.7-3.6(64H,m), - 3.41(2H,s). ZnCRPc was obtained by reaction of...J.P.; Bencosme, S.; Evitt, E., Sessler, J. Chem. Phys. 1984, 86, 161. Mialoco, C.; Giannotti, A., Maillard , P.; Momeuteau, M. Chem. Phys. Lett. 1984

  15. A new high-speed hollow fiber based liquid phase microextraction method using volatile organic solvent for determination of aromatic amines in environmental water samples prior to high-performance liquid chromatography.

    PubMed

    Sarafraz-Yazdi, A; Mofazzeli, F; Es'haghi, Z

    2009-07-15

    A new and fast hollow fiber based liquid phase microextraction (HF-LPME) method using volatile organic solvents coupled with high-performance liquid chromatography (HPLC) was developed for determination of aromatic amines in the environmental water samples. Analytes including 3-nitroaniline, 3-chloroaniline and 4-bromoaniline were extracted from 6 mL basic aqueous sample solution (donor phase, NaOH 1 mol L(-1)) into the thin film of organic solvent that surrounded and impregnated the pores of the polypropylene hollow fiber wall (toluene, 20 microL), then back-extracted into the 6 mL acidified aqueous solution (acceptor phase, HCl 0.5 mol L(-1)) in the lumen of the two-end sealed hollow fiber. After the extraction, 5 microL of the acceptor phase was withdrawn into the syringe and injected directly into the HPLC system for the analysis. The parameters influencing the extraction efficiency including the kind of organic solvent and its volume, composition of donor and acceptor phases and the volume ratio between them, extraction time, stirring rate, salt addition and the effect of the analyte complexation with 18-crown-6 ether were investigated and optimized. Under the optimal conditions (donor phase: 6 mL of 1 mol L(-1) NaOH with 10% NaCl; organic phase: 20 microL of toluene; acceptor phase: 6 microL of 0.5 mol L(-1) HCl and 600 mmol L(-1) 18-crown-6 ether; pre-extraction and back-extraction times: 75 s and 10 min, respectively; stirring rate: 800 rpm), the obtained EFs were between 259 and 674, dynamic linear ranges were 0.1-1000 microg L(-1) (R>0.9991), and also the limits of detection were in the range of 0.01-0.1 micro gL(-1). The proposed procedure worked very well for real environmental water samples with microgram per liter level of the analytes, and good relative recoveries (91-102%) were obtained for the spiked sample solutions.

  16. Crystal structure of (18-crown-6)potassium(I) [(1,2,3,4,5-η)-cyclo-hepta-dien-yl][(1,2,3-η)-cyclo-hepta-trien-yl]cobalt(I).

    PubMed

    Brennessel, William W; Ellis, John E

    2015-03-01

    The reaction of bis-(anthracene)cobaltate(-I) with excess cyclo-hepta-triene, C7H8, resulted in a new 18-electron cobaltate containing two different seven-membered ring ligands, based on single-crystal X-ray diffraction. The asymmetric unit of this structure contains two independent cation-anion pairs of the title complex, [K(18-crown-6)][Co(η(3)-C7H7)(η(5)-C7H9)], where 18-crown-6 stands for 1,4,7,10,13,16-hexa-oxa-cyclo-octa-decane (C12H24O6), in general positions and well separated. Each (18-crown-6)potassium cation is in contact with the η(3)-coordinating ligand of one cobaltate complex. Each η(3)-coordinating ligand behaves as an allylic anion whose exo-diene moiety is bent away from the allylic plane, and thus is not involved directly in the bonding. The metal-coordinating portions of the anionic η(5) ligands are planar and one of these ligands is modeled as disordered over two positions, with occupancy ratio 0.699 (5):0.301 (5), such that one orientation is rotated by one carbon atom with respect to the other. The diffraction intensities were integrated according to non-merohedral twin law [-1 0 0/0 -1 0/0.064 0 1], a 180° rotation about reciprocal lattice axis [001], and the masses of the twin domains refined to equal amounts. As both ligands are formally coordinated as anions, the cobalt atom is best considered to be Co(I). This compound is of inter-est as the first to possess cyclo-hepta-trienyl and cyclo-hepta-dienyl ligands in an anionic metal complex.

  17. Electroregulated Metal-Binding with a Crown Ether Tetrathiafulvalene Derivative: Toward Electrochemically Addressed Metal Cation Sponges.

    PubMed

    Le Derf, Franck; Mazari, Miloud; Mercier, Nicolas; Levillain, Eric; Richomme, Pascal; Becher, Jan; Garín, Javier; Orduna, Jesus; Gorgues, Alain; Sallé, Marc

    1999-12-27

    A redox responsive ligand incorporating the tetrathiafulvalene unit has been synthesized. The crystal structure of the free ligand (Z)-1 (C(20)H(30)O(5)S(8), triclinic P&onemacr;, Z = 2, a = 9.087(6) Å, b = 11.637(7) Å, c = 14.370(8) Å, alpha = 65.54(3) degrees, beta = 82.32(5) degrees, gamma = 84.18(6) degrees, V = 1368 Å(3)) shows the redox-active tetrathiafulvalene core to be essentially planar, which allows observation of two reversible one-electron processes upon electrochemical oxidation. The efficiency of this system in the control of the reversible complexation/expulsion sequence of a metallic cation (i.e., Ba(2+)) has been made possible thanks to a combination of (a) an unprecedented high coordination ability among tetrathiafulvalene-based macrocycles as determined by LSI mass spectrometry (log K degrees = 3.5, NBA-matrix) as well as by solution investigations ((1)H NMR and cyclic voltammetry titration studies), which remarkably converge to similar binding constant values (i.e., log K degrees = 4.2-4.3), and (b) reversible metal cation expulsion upon electrochemical oxidation to the dicationic state. A channel-like solid-state structure is observed for the Ba(2+) complex (C(20)H(30)O(5)S(8), Ba(2+)(CF(3)SO(3))(2)(2-), (H(2)O)(2), CD(3)CN, monoclinic C2/c, Z = 8, a = 45.66(1) Å, b = 8.897(5) Å, c = 23.124(8) Å, beta = 105.54(4) degrees, V = 9050 Å(3)), which results from the segregated stacking mode of the crown ether and the redox-active tetrathiafulvalene subunits, respectively.

  18. Gibbs energies of transferring triglycine from water into H2O-DMSO solvent

    NASA Astrophysics Data System (ADS)

    Usacheva, T. R.; Kuz'mina, K. I.; Lan, Pham Thi; Kuz'mina, I. A.; Sharnin, V. A.

    2014-08-01

    The Gibbs energies of transferring triglycine (3Gly, glycyl-glycyl-glycine) from water into mixtures of water with dimethyl sulfoxide (χDMSO = 0.05, 0.10, and 0.15 mole fractions) at 298.15 K are determined from the interphase distribution. An increased dimethyl sulfoxide (DMSO) concentration in the solvent slightly raises the positive values of Δtr G ○(3Gly), possibly indicating the formation of more stable 3Gly-H2O solvated complexes than ones of 3Gly-DMSO. It is shown that the change in the Gibbs energy of transfer of 3Gly is determined by the enthalpy component. The relationship of 3Gly and 18-crown-6 ether (18C6) solvation's contributions to the change in the Gibbs energy of [3Gly18C6] molecular complex formation in H2O-DMSO solvents is analyzed, and the key role of 3Gly solvation's contribution to the change in the stability of [3Gly18C6] upon moving from H2O to mixtures with DMSO is revealed.

  19. Calix[4]arene-bis(t-octylbenzo-18-crown-6) as an extraordinarily effective macrocyclic receptor for the univalent thallium cation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makrlik, Emanuel; Toman, Petr; Vanura, Petr

    2013-01-01

    From extraction experiments and -activity measurements, the exchange extraction constant corresponding to the equilibrium Tl+ (aq) + 1 Cs+ (org) 1 Tl+ (org) + Cs+ (aq) taking place in the two-phase water phenyltrifluoromethyl sulfone (abbrev. FS 13) system (1 = calix[4]arene-bis(t-octylbenzo-18-crown-6); aq = aqueous phase, org = FS 13 phase) was evaluated as log Kex (Tl+, 1 Cs+) = 1.7 0.1. Further, the extraordinarily high stability constant of the 1 Tl+ complex in FS 13 saturated with water was calculated for a temperature of 25 C: log org(1 Tl+) = 13.1 0.2. Finally, by using quantum mechanical DFT calculations, themore » most probable structure of the cationic complex species 1 Tl+ was derived. In the resulting 1 Tl+ complex, the central cation Tl+ is bound by eight bond interactions to six oxygen atoms from the respective 18-crown-6 moiety and to two carbons of the corresponding two benzene rings of the parent receptor 1 via cation interaction.« less

  20. Interaction of the cesium cation with calix[4]arene-bis(t-octylbenzo-18-crown-6): Extraction and DFT study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makrlik, Emanuel; Toman, Petr; Vanura, Petr

    2013-01-01

    From extraction experiments and c-activity measurements, the extraction constant corresponding to the equilibrium Cs+ (aq) + I (aq) + 1 (org),1Cs+ (org) + I (org) taking place in the two-phase water-phenyltrifluoromethyl sulfone (abbrev. FS 13) system (1 = calix[4]arene-bis(t-octylbenzo-18-crown-6); aq = aqueous phase, org = FS 13 phase) was evaluated as logKex (1Cs+, I) = 2.1 0.1. Further, the stability constant of the 1Cs+ complex in FS 13 saturated with water was calculated for a temperature of 25 C: log borg (1Cs+) = 9.9 0.1. Finally, by using quantum mechanical DFT calculations, the most probable structure of the cationic complexmore » species 1Cs+ was derived. In the resulting 1Cs+ complex, the central cation Cs+ is bound by eight bond interactions to six oxygen atoms of the respective 18-crown-6 moiety and to two carbons of the corresponding two benzene rings of the parent ligand 1 via cation p interaction.« less

  1. A colorimetric chiral sensor based on chiral crown ether for the recognition of the two enantiomers of primary amino alcohols and amines.

    PubMed

    Cho, Eun Na Rae; Li, Yinan; Kim, Hee Jin; Hyun, Myung Ho

    2011-04-01

    A new colorimetric chiral sensor material consisting of three different functional sites such as chromophore (2,4-dinitrophenylazophenol dye), binding site (crown ether), and chiral barrier (3,3'-diphenyl-1,1'-binaphthyl group) was prepared and applied to the recognition of the two enantiomers of primary amino alcohols and amines. Among five primary amino alcohols and two primary amines tested, the two enantiomers of phenylalaninol show the highest difference in the absorption maximum wavelength (Δλ(max)=43.5 nm) and in the association constants (K(S)/K(R)=2.51) upon complexation with the colorimetric chiral sensor material and, consequently, the two enantiomers of phenylalaninol were clearly distinguished from each other by the color difference. Copyright © 2010 Wiley-Liss, Inc.

  2. Comparison of classic and microwave-assisted synthesis of benzo-thio crown ethers, and investigation of their ion pair extractions

    NASA Astrophysics Data System (ADS)

    Calisir, Umit; Çiçek, Baki

    2017-11-01

    Macrocyclic benzo-thio crown ethers and benzo-oxo crown ethers were prepared using an esterification-ring closing method. These compounds were synthesised using 2,2‧-dithiodibenzoyl chloride, and various glycols and dithiols, in the presence of pyridine base under a nitrogen atmosphere in chloroform. All reactions were performed under reflux condition with conventional heating and microwave (MW) irradiation. The synthesised macrocycles were characterised by FT-IR, 1H NMR, 13C NMR, LC-MS, and elemental analysis methods. Extraction studies have been performed on these original macrocycles using liquid-liquid ion-pair extraction with Li+, Na+, K+, Ni2+, Ca2+, Mg2+, Zn2+, Fe2+,Fe3+, Co3+, Pb2+, Cr3+, Ag+, and Cd2+.The KD, ext.%, ΔG and log KExt values were also calculated. While (U1-U7) ligands exhibits selectivity for Zn2+, Ag+, Ca2+, Pb2+, Fe3+, Cr3+, Co2+, Mg2+, Cd2+, and Ni2+ metal salts, they showed no selectivity for Li+, K+ and Na+ metal salts. Furthermore, Fe3+is the most selective cation for all ligands for competitive extraction. We also observed that microwave heating can have certain benefits over conventional ovens: reaction rate acceleration, milder reaction conditions, higher chemical yield, and lower energy usage. These ligands could be used as metal sensors, enzyme inhibitors, antimicrobial/antifungal agents, and in biological applications.

  3. [Determination of inorganic ions in explosive residues by capillary zone electrophoresis].

    PubMed

    Feng, Junhe; Guo, Baoyuan; Lin, Jin-Ming; Xu, Jianzhong; Zhou, Hong; Sun, Yuyou; Liu, Yao; Quan, Yangke; Lu, Xiaoming

    2008-11-01

    Five anions (chlorate, perchlorate, nitrate, nitrite, and sulfate) and two cations (ammonium and potassium) in explosive residues have been separated and determined by capillary zone electrophoresis (CZE) with indirect ultraviolet detection. The electrolyte buffer for the cation separation was 10 mmol/L pyridine (pH 4.5) -3 mmol/L 18-crown-6-ether. Ammonium and potassium ions were baseline separated in less than 2.6 min with the detection limits of 0.10 mg/L and 0.25 mg/L (S/N = 3), respectively. The electrolyte buffer for the anion separation consisted of 40 mmol/L boric acid-1.8 mmol/L potassium dichromate-2 mmol/L sodium tetraborate (pH 8.6), and tetramethyl ammonium hydroxide (TMAOH) was used as electroosmotic flow modifier. All five anions were well separated in less than 4.6 min with the detection limit range of 0.10 - 1.85 mg/L (S/N = 3). The method was successfully used in real sample investigations to confirm the type of explosives.

  4. Complexation of molecular clips containing fragments of diphenylglycoluril and benzocrown ethers with paraquat and its derivatives

    PubMed Central

    Kikot', Leonid S; Kulygina, Catherine Yu; Lyapunov, Alexander Yu; Shishkina, Svetlana V; Zubatyuk, Roman I; Bogaschenko, Tatiana Yu

    2017-01-01

    The complexation of molecular clips containing fragments of diphenylglycoluril and benzocrown ethers with paraquat and its derivatives has been studied both in solution and in the solid state. In this paper we studied the influence of the crown ether ring size and the nature of the substituents at the nitrogen atoms of the paraquat derivatives on the composition and stability of these complexes. PMID:29062427

  5. Homoleptic diphosphacyclobutadiene complexes [M(η(4)-P2C2R2)2]x- (M = Fe, Co; x = 0, 1).

    PubMed

    Wolf, Robert; Ehlers, Andreas W; Khusniyarov, Marat M; Hartl, František; de Bruin, Bas; Long, Gary J; Grandjean, Fernande; Schappacher, Falko M; Pöttgen, Rainer; Slootweg, J Chris; Lutz, Martin; Spek, Anthony L; Lammertsma, Koop

    2010-12-27

    The preparation and comprehensive characterization of a series of homoleptic sandwich complexes containing diphosphacyclobutadiene ligands are reported. Compounds [K([18]crown-6)(thf)(2)][Fe(η(4)-P(2)C(2)tBu(2))(2)] (K1), [K([18]crown-6)(thf)(2)][Co(η(4)-P(2)C(2)tBu(2))(2)] (K2), and [K([18]crown-6)(thf)(2)][Co(η(4)-P(2)C(2)Ad(2))(2)] (K3, Ad = adamantyl) were obtained from reactions of [K([18]crown-6)(thf)(2)][M(η(4)-C(14)H(10))(2)] (M = Fe, Co) with tBuC[triple bond]P (1, 2), or with AdC[triple bond]P (3). Neutral sandwiches [M(η(4)-P(2)C(2)tBu(2))(2)] (4: M = Fe 5: M = Co) were obtained by oxidizing 1 and 2 with [Cp(2)Fe]PF(6). Cyclic voltammetry and spectro-electrochemistry indicate that the two [M(η(4)-P(2)C(2)tBu(2))(2)](-)/[M(η(4)-P(2)C(2)tBu(2))(2)] moieties can be reversibly interconverted by one electron oxidation and reduction, respectively. Complexes 1-5 were characterized by multinuclear NMR, EPR (1 and 5), UV/Vis, and Mössbauer spectroscopies (1 and 4), mass spectrometry (4 and 5), and microanalysis (1-3). The molecular structures of 1-5 were determined by using X-ray crystallography. Essentially D(2d)-symmetric structures were found for all five complexes, which show the two 1,3-diphosphacyclobutadiene rings in a staggered orientation. Density functional theory calculations revealed the importance of covalent metal-ligand π bonding in 1-5. Possible oxidation state assignments for the metal ions are discussed.

  6. Laser all-ceramic crown removal and pulpal temperature--a laboratory proof-of-principle study.

    PubMed

    Rechmann, P; Buu, N C H; Rechmann, B M T; Finzen, F C

    2015-11-01

    The objective of this proof-of-principle laboratory pilot study was to evaluate the temperature increase in the pulp chamber in a worst case scenario during Er:YAG laser debonding of all-ceramic crowns. Twenty extracted molars were prepared to receive all-ceramic IPS E.max CAD full contour crowns. The crowns were bonded to the teeth with Ivoclar Multilink Automix. Times for laser debonding and temperature rise in the pulp chamber using micro-thermocouples were measured. The Er:YAG was used with 560 mJ/pulse. The irradiation was applied at a distance of 5 mm from the crown surface. Additional air-water spray for cooling was utilized. Each all-ceramic crown was successfully laser debonded with an average debonding time of 135 ± 35 s. No crown fractured, and no damage to the underlying dentin was detected. The bonding cement deteriorated, but no carbonization at the dentin/cement interface occurred. The temperature rise in the pulp chamber averaged 5.4° ± 2.2 °C. During 8 out of the 20 crown removals, the temperature rise exceeded 5.5 °C, lasting 5 to 43 s (average 18.8 ± 11.6 s). A temperature rise of 11.5 °C occurred only once, while seven times the temperature rise was limited to 6.8 ± 0.5 °C. Temperature rises above 5.5 °C occurred only when the laser was applied from one side and additional cooling from the side opposite the irradiation. Er:YAG laser energy can successfully be used to efficiently debond all-ceramic crowns from natural teeth. Temperature rises exceeding 5.5 °C only occur when an additional air/water cooling from a dental syringe is inaccurately directed. To avoid possible thermal damage and to allow further heat diffusion, clinically temperature-reduced water might be applied.

  7. Influence of different post core materials on the color of Empress 2 full ceramic crowns.

    PubMed

    Ge, Jing; Wang, Xin-zhi; Feng, Hai-lan

    2006-10-20

    For esthetic consideration, dentin color post core materials were normally used for all-ceramic crown restorations. However, in some cases, clinicians have to consider combining a full ceramic crown with a metal post core. Therefore, this experiment was conducted to test the esthetical possibility of applying cast metal post core in a full ceramic crown restoration. The color of full ceramic crowns on gold and Nickel-Chrome post cores was compared with the color of the same crowns on tooth colored post cores. Different try-in pastes were used to imitate the influence of a composite cementation on the color of different restorative combinations. The majority of patients could not detect any color difference less than DeltaE 1.8 between the two ceramic samples. So, DeltaE 1.8 was taken as the objective evaluative criterion for the evaluation of color matching and patients' satisfaction. When the Empress 2 crown was combined with the gold alloy post core, the color of the resulting material was similar to that of a glass fiber reinforced resin post core (DeltaE = 0.3). The gold alloy post core and the try-in paste did not show a perceptible color change in the full ceramic crowns, which indicated that the color of the crowns might not be susceptible to change between lab and clinic as well as during the process of composite cementation. Without an opaque covering the Ni-Cr post core would cause an unacceptable color effect on the crown (DeltaE = 2.0), but with opaque covering, the color effect became more clinically satisfactory (DeltaE = 1.8). It may be possible to apply a gold alloy post core in the Empress 2 full ceramic crown restoration when necessary. If a non-extractible Ni-Cr post core exists in the root canal, it might be possible to restore the tooth with an Empress 2 crown after covering the labial surface of the core with one layer of opaque resin cement.

  8. [Clinical evaluation of the effect of gold alloy and Ni-Cr alloy porcelain fused metal crown restorations].

    PubMed

    Sun, Wei-ge; Liu, Xiang-hui; Zhang, Ling; Zhang, Chun; Xie, Ming-yi; Zhou, Wen-juan

    2009-02-01

    To observe the clinical effect of gold alloy porcelain fused metal (PFM) crown restoration and Ni-Cr alloy PFM crown restoration. A total of 168 teeth from 48 patients were restored with gold alloy PFM crown. The other 48 patients, with a total of 179 teeth were restored with Ni-Cr alloy PFM crown. They were examined in integrality, retention, shade, cervical margin, and gingival health immediately, 6 months, one year, two years ,and three years after restoration. The date was analyzed by rank sum test using SPSS12.0 software package. The clinical effect of Ni-Cr alloy PFM crown was as good as gold alloy PFM crown when checked up after cementation at once. However, when they were examined 6 months, one year, two years ,and three years after restoration, the clinical effect of gold alloy PFM crown group was significantly better than that of Ni-Cr alloy PFM crown, P<0.05. The gold alloy PFM crown has better properties than Ni-Cr alloy PFM crown as a kind of long-term restoration, especially on the aspect of shade.

  9. A novel fluorescent probe for Cr3 + based on rhodamine-crown ether conjugate and its application to drinking water examination and bioimaging

    NASA Astrophysics Data System (ADS)

    Diao, Quanping; Ma, Pinyi; Lv, Linlin; Li, Tiechun; Wang, Xinghua; Song, Daqian

    2016-03-01

    A trivalent chromium (Cr3 +) fluorescence probe (RhC) was designed and synthesized via Schiff base reaction based on rhodamine-crown ether conjugate. This probe displayed a favorable selectivity for Cr3 + over a range of other common metal ions in DMF/H2O (3:7, v/v; PBS buffer 50 mmol L- 1; pH = 6.8) solution, leading to prominent fluorescence "OFF-ON" switching of the rhodamine fluorophore. The limit of detection was calculated to be 1.5 μmol L- 1 (S/N = 3). The binding ratio of RhC-Cr3 + complex was determined to be 1:2 according to the Job's plot and HR-MS. The probe was successfully applied to examination of Cr3 + in drinking water spiked samples. The average recoveries ranged from 104.9% to 106.9% at spiked concentration level of 10.00 μmol L- 1, and the obtained results were consistent with those obtained using atomic absorption spectrometry (AAS). Moreover, bioimaging experiments showed that RhC can sense the Cr3 + in living cells with a fluorescence enhancement signal.

  10. A comparison of complexation of Li+ ion with macrocyclic ligands 15-crown-5 and 12-crown-4 in binary nitromethane-acetonitrile mixtures by using lithium-7 NMR technique and ab initio calculation.

    PubMed

    Alizadeh, Nina

    2011-01-01

    Lithium-7 NMR measurements were used to investigate the stoichiometry and stability of Li+ complexes with 15-crown-5 (15C5), benzo-15-crown-5 (B15C5), dibenzo-15-crown-5 (DB15C5) and 12-crown-4 (12C4) in a number of nitromethane (NM)-acetonitrile (AN) binary mixtures. In all cases, the exchange between the free and complexed lithium ion was fast on the NMR time scale and a single population average resonance was observed. While all crown ethers form 1:1 complexes with Li+ ion in the binary mixtures used, both 1:1 and 2:1 (sandwich) complexes were observed between lithium ion and 12C4 in pure nitromethane solution. Stepwise formation constants of the 1:1 and 2:1 (ligand/metal) complexes were evaluated from computer fitting of the NMR-mole ratio data to equations which relate the observed metal ion chemical shifts to formation constants. There is an inverse linear relationship between the logarithms of the stability constants and the mole fraction of acetonitrile in the solvent mixtures. The stability order of the 1:1 complexes was found to be 15C5·Li+>B15C5·Li+>DB15C5·Li+>12C4·Li+. The optimized structures of the free ligands and their 1:1 and 2:1 complexes with Li+ ion were predicted by ab initio theoretical calculations using the Gaussian 98 software, and the results are discussed. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Electroactive crown ester-Cu2+ complex with in-situ modification at molecular beacon probe serving as a facile electrochemical DNA biosensor for the detection of CaMV 35s.

    PubMed

    Zhan, Fengping; Liao, Xiaolei; Gao, Feng; Qiu, Weiwei; Wang, Qingxiang

    2017-06-15

    A novel electrochemical DNA biosensor has been facilely constructed by in-situ assembly of electroactive 4'-aminobenzo-18-crown-6-copper(II) complex (AbC-Cu 2+ ) on the free terminal of the hairpin-structured molecule beacon. The 3'-SH modified molecule beacon probe was first immobilized on the gold electrode (AuE) surface through self-assembly chemistry of Au-S bond. Then the crow ester of AbC was covalently coupled with 5'-COOH on the molecule beacon, and served as a platform to attach the Cu 2+ by coordination with ether bond (-O-) of the crown cycle. Thus, an electroactive molecule beacon-based biosensing interface was constructed. In comparison with conventional methods for preparation of electroactive molecule beacon, the approach presented in this work is much simpler, reagent- and labor-saving. Selectivity study shows that the in-situ fabricated electroactive molecule beacon remains excellent recognition ability of pristine molecule beacon probe to well differentiate various DNA fragments. The target DNA can be quantatively determined over the range from 0.10pM to 0.50nM. The detection limit of 0.060pM was estimated based on signal-to-noise ratio of 3. When the biosensor was applied for the detection cauliflower mosaic virus 35s (CaMV 35s) in soybean extraction samples, satisfactory results are achieved. This work opens a new strategy for facilely fabricating electrochemical sensing interface, which also shows great potential in aptasensor and immurosensor fabrication. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Marginal Fit of Lithium Disilicate Crowns Fabricated Using Conventional and Digital Methodology: A Three-Dimensional Analysis.

    PubMed

    Mostafa, Nezrine Z; Ruse, N Dorin; Ford, Nancy L; Carvalho, Ricardo M; Wyatt, Chris C L

    2018-02-01

    To compare the marginal fit of lithium disilicate (LD) crowns fabricated with digital impression and manufacturing (DD), digital impression and traditional pressed manufacturing (DP), and traditional impression and manufacturing (TP). Tooth #15 was prepared for all-ceramic crowns on an ivorine typodont. There were 45 LD crowns fabricated using three techniques: DD, DP, and TP. Microcomputed tomography (micro-CT) was used to assess the 2D and 3D marginal fit of crowns in all three groups. The 2D vertical marginal gap (MG) measurements were done at 20 systematically selected points/crown, while the 3D measurements represented the 3D volume of the gap measured circumferentially at the crown margin. Frequencies of different marginal discrepancies were also recorded, including overextension (OE), underextension (UE), and marginal chipping. Crowns with vertical MG > 120 μm at more than five points were considered unacceptable and were rejected. The results were analyzed by one-way ANOVA with Scheffe post hoc test (α = 0.05). DD crowns demonstrated significantly smaller mean vertical MG (33.3 ± 19.99 μm) compared to DP (54.08 ± 32.34 μm) and TP (51.88 ± 35.34 μm) crowns. Similarly, MG volume was significantly lower in the DD group (3.32 ± 0.58 mm 3 ) compared to TP group (4.16 ± 0.59 mm 3 ). The mean MG volume for the DP group (3.55 ± 0.78 mm 3 ) was not significantly different from the other groups. The occurrence of underextension error was higher in DP (6.25%) and TP (5.4%) than in DD (0.33%) group, while overextension was more frequent in DD (37.67%) than in TP (28.85%) and DP (18.75%) groups. Overall, 4 out of 45 crowns fabricated were deemed unacceptable based on the vertical MG measurements (three in TP group and one in DP group; all crowns in DD group were deemed acceptable). The results suggested that digital impression and CAD/CAM technology is a suitable, better alternative to traditional impression and manufacturing. © 2017 by the American College of Prosthodontists.

  13. Novel heavy-metal adsorption material: ion-recognition P(NIPAM-co-BCAm) hydrogels for removal of lead(II) ions.

    PubMed

    Ju, Xiao-Jie; Zhang, Shi-Bo; Zhou, Ming-Yu; Xie, Rui; Yang, Lihua; Chu, Liang-Yin

    2009-08-15

    A novel polymeric lead(II) adsorbent is prepared by incorporating benzo-18-crown-6-acrylamide (BCAm) as metal ion receptor into the thermo-responsive poly(N-isopropylacrylamide) (PNIPAM) hydrogel. Both stimuli-sensitive properties and the Pb(2+)-adsorption capabilities of the prepared P(NIPAM-co-BCAm) hydrogels are investigated. The prepared P(NIPAM-co-BCAm) hydrogels exhibit good ion-recognition and Pb(2+)-adsorption characteristics. When crown ether units capture Pb(2+) and form BCAm/Pb(2+) host-guest complexes, the lower critical solution temperature (LCST) of the hydrogel shifts to a higher temperature due to both the repulsion among charged BCAm/Pb(2+) groups and the osmotic pressure within the hydrogel. The adsorption results at different temperatures show that P(NIPAM-co-BCAm) hydrogels adsorb Pb(2+) ions at temperature lower than the LCST, but undergo desorption at temperature higher than the LCST due to the "stretch-to-shrink" configuration change of copolymer networks which is triggered by the change in environmental temperature. This kind of ion-recognition hydrogel is promising as a novel adsorption material for adsorption and separation of Pb(2+) ions. The adsorption and desorption of Pb(2+) could be rationally achieved by simply changing the environmental temperature.

  14. Li+-Permeable Film on Lithium Anode for Lithium Sulfur Battery.

    PubMed

    Yang, Yan-Bo; Liu, Yun-Xia; Song, Zhiping; Zhou, Yun-Hong; Zhan, Hui

    2017-11-08

    Lithium-sulfur (Li-S) battery is an important candidate for next-generation energy storage. However, the reaction between polysulfide and lithium (Li) anode brings poor cycling stability, low Coulombic efficiency, and Li corrosion. Herein, we report a Li protection technology. Li metal was treated in crown ether containing electrolyte, and thus, treated Li was further used as the anode in Li-S cell. Due to the coordination between Li + and crown ether, a Li + -permeable film can be formed on Li, and the film is proved to be able to block the detrimental reaction between Li anode and polysulfide. By using the Li anode pretreated in 2 wt % B15C5-containing electrolyte, Li-S cell exhibits significantly improved cycling stability, such as∼900 mAh g -1 after 100 cycles, and high Coulombic efficiency of>93%. In addition, such effect is also notable when high S loading condition is applied.

  15. Response of a benzoxainone derivative linked to monoaza-15-crown-5 with divalent heavy metals.

    PubMed

    Addleman, R S; Bennett, J; Tweedy, S H; Elshani, S; Wai, C M

    1998-08-01

    The response of a monoaza-15-crown-5 with an optically active aminobenzoxazinone moiety to divalent cations was investigated. The crown ether was found to undergo a strong emission shift to the blue when complexed with specific divalent metals that have ionic diameters between 1.9-2.4 A. Consequently the photoactive macrocycle is responsive to Mg(2+), Ca(2+), Ba(2+), Sr(2+), Cd(2+), and particularly responsive to Hg(2+)and Pb(2+). Macrocycle emission spectra are shown to be a function of cation concentration. Alkaline metal cations and smaller transition metals ions such as Ni(2+), Co(2+)and Zn(2+)do not cause significant changes in the macrocycle emission spectra. Emission, absorption, and complex stability constants are determined. Mechanisms of cation selectivity and spectral emission shifts are discussed. Challenges involving immobilization of the macrocycle while preserving its spectral response to cations are explored.

  16. Solvent extraction of Li+, H3O+ and NH4+ into nitrobenzene by using sodium dicarbollylcobaltate and calix[4]arene-bis(t-octylbenzo-18-crown-6)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makrlik, Emanuel; Selucky, P.; Vanura, Petr

    2013-01-01

    From extraction experiments and c-activity measurements, the exchange extraction constants corresponding to the general equilibrium M+ (aq) + NaL+ (nb) , ML+ (nb) + Na+ (aq) taking place in the two-phase water nitrobenzene system (M+ = Li+, H3O+, NH+4; L = calix[4]arene-bis(t-octylbenzo-18-crown-6); aq = aqueous phase, nb = nitrobenzene phase) were evaluated. Furthermore, the stability constants of the ML+ complexes in nitrobenzene saturated with water were calculated; they were found to increase in the following cation order: zH3O+ < Li+ < NH+4.

  17. AFOSR Technical Report Summaries, April-June 1986,

    DTIC Science & Technology

    1986-06-01

    C1HARGE DENSITY. ELECTRODES. INTERrACIAL TENSION. PRESSURE, SIIRFACE PROPERTIES. CORROSION INHIBITION, MOLECULES, ORGANIC COMPOUNDS . SORPTION . FILMS... Perfluorinated derivatives of hydrocarbon Compounds usually ewhibit different propeties than their hydrocarbon analogues. The perfluoro crown ether-s are m.arkedly...Binary Hydrocarbon Mixtures, AD-A166 130 Materials for Emergency Repair AD-A167 094 of Runways. -BROMINE COMPOUNDS AD-Ai64 225 tCHEMICAL LASERS Analysis of

  18. [Comparative adaptation of crowns of selective laser melting and wax-lost-casting method].

    PubMed

    Li, Guo-qiang; Shen, Qing-yi; Gao, Jian-hua; Wu, Xue-ying; Chen, Li; Dai, Wen-an

    2012-07-01

    To investigate the marginal adaptation of crowns fabricated by selective laser melting (SLM) and wax-lost-casting method, so as to provide an experimental basis for clinic. Co-Cr alloy full crown were fabricated by SLM and wax-lost-casting for 24 samples in each group. All crowns were cemented with zinc phosphate cement and cut along longitudinal axis by line cutting machine. The gap between crown tissue surface and die was measured by 6-point measuring method with scanning electron microscope (SEM). The marginal adaptation of crowns fabricated by SLM and wax-lost-casting were compared statistically. The gap between SLM crowns were (36.51 ± 2.94), (49.36 ± 3.31), (56.48 ± 3.35), (42.20 ± 3.60) µm, and wax-lost-casting crowns were (68.86 ± 5.41), (58.86 ± 6.10), (70.62 ± 5.79), (69.90 ± 6.00) µm. There were significant difference between two groups (P < 0.05). Co-Cr alloy full crown fabricated by wax-lost-casting method and SLM method provide acceptable marginal adaptation in clinic, and the marginal adaptation of SLM is better than that of wax-lost-casting method.

  19. Macrocyclic receptors immobilized to monodisperse porous polymer particles by chemical grafting and physical impregnation for strontium capture: a comparative study.

    PubMed

    Song, Yang; Du, Yi; Lv, Dachao; Ye, Gang; Wang, Jianchen

    2014-06-15

    Separation of strontium is of great significance for radioactive waste treatment and environmental remediation after nuclear accidents. In this work, a novel class of adsorbent (Crown-g-MPPPs) was synthesized by chemical grafting a macrocyclic ether receptor to monodisperse porous polymer particles (MPPPs) for strontium adsorption. Meanwhile, a counterpart material (Crown@MPPPs) with the receptor molecules immobilized to the MPPPs substrate by physical impregnation was prepared. To investigate how the immobilization manner and distribution of the receptors influence the adsorption ability, a comparative study on the adsorption behaviour of the two materials towards Sr(II) in HNO3 media was accomplished. Due to the shorter diffusion path and covalently-bonded structure, Crown-g-MPPPs showed faster adsorption kinetics and better stability for cycle use. While Crown@MPPPs had the advantages of facile synthesis and higher adsorption capacity, owing to the absence of conformational constraint to form complexation with Sr(II). Kinetic functions (Lagergren pseudo-first-order/pseudo-second-order functions) and adsorption isotherm models (Langmuir/Freundlich models) were used to fit the experimental data and examine the adsorption mechanism. On this basis, a chromatographic process was proposed by using Crown@MPPPs for an effective separation of Sr(II) (91%) in simulated high level liquid waste (HLLW). Copyright © 2014 Elsevier B.V. All rights reserved.

  20. [Quantitative assessment on artifacts of dental restorative materials in cone beam computed tomography].

    PubMed

    Yuan, Fu-song; Sun, Yu-chun; Xie, Xiao-yan; Wang, Yong; Lv, Pei-jun

    2013-12-18

    To quantitatively evaluate the artifacts appearance of eight kinds of common dental restorative materials, such as zirconia. For the full-crown tooth preparation of mandibular first molar, eight kinds of full-crowns, such as zirconia all-ceramic crown, glass ceramic crown, ceramage crown, Au-Pt based porcelain-fused-metal (PFM) crown, Pure Titanium PFM crown, Co-Cr PFM crown, Ni-Cr PFM crown, and Au-Pd metal crown were fabricated. And natural teeth in vitro were used as controls. These full-crown and natural teeth in vitro were mounted an ultraviolet-curable resin fixed plate. High resolution cone beam computed tomography (CBCT) was used to scan all of the crowns and natural teeth in vitro, and their DICOM data were imported into software MIMICS 10.0. Then, the number of stripes and the maximum diameters of artifacts around the full-crowns were evaluated quantitatively in two-dimensional tomography images. In the two-dimensional tomography images,the artifacts did not appear around the natural teeth in vitro, glass ceramic crown, and ceramage crown. But thr artifacts appeared around the zirconia all-ceramic and metal crown. The number of stripes of artifacts was five to nine per one crown. The maximum diameters of the artifacts were 2.4 to 2.6 cm and 2.2 to 2.7 cm. In the two-dimensional tomography images of CBCT, stripe-like and radical artifacts were caused around the zirconia all-ceramic crown and metal based porcelain-fused-metal crowns. These artifacts could lower the imaging quality of the full crown shape greatly. The artifact was not caused around the natural teeth in vitro, glass ceramic crown, and ceramage crown.

  1. Multistate λ-local-elevation umbrella-sampling (MS-λ-LEUS): method and application to the complexation of cations by crown ethers.

    PubMed

    Bieler, Noah S; Tschopp, Jan P; Hünenberger, Philippe H

    2015-06-09

    An extension of the λ-local-elevation umbrella-sampling (λ-LEUS) scheme [ Bieler et al. J. Chem. Theory Comput. 2014 , 10 , 3006 ] is proposed to handle the multistate (MS) situation, i.e. the calculation of the relative free energies of multiple physical states based on a single simulation. The key element of the MS-λ-LEUS approach is to use a single coupling variable Λ controlling successive pairwise mutations between the states of interest in a cyclic fashion. The Λ variable is propagated dynamically as an extended-system variable, using a coordinate transformation with plateaus and a memory-based biasing potential as in λ-LEUS. Compared to other available MS schemes (one-step perturbation, enveloping distribution sampling and conventional λ-dynamics) the proposed method presents a number of important advantages, namely: (i) the physical states are visited explicitly and over finite time periods; (ii) the extent of unphysical space required to ensure transitions is kept minimal and, in particular, one-dimensional; (iii) the setup protocol solely requires the topologies of the physical states; and (iv) the method only requires limited modifications in a simulation code capable of handling two-state mutations. As an initial application, the absolute binding free energies of five alkali cations to three crown ethers in three different solvents are calculated. The results are found to reproduce qualitatively the main experimental trends and, in particular, the experimental selectivity of 18C6 for K(+) in water and methanol, which is interpreted in terms of opposing trends along the cation series between the solvation free energy of the cation and the direct electrostatic interactions within the complex.

  2. Expanding Thorium Hydride Chemistry Through Th²⁺, Including the Synthesis of a Mixed-Valent Th⁴⁺/Th³⁺ Hydride Complex.

    PubMed

    Langeslay, Ryan R; Fieser, Megan E; Ziller, Joseph W; Furche, Filipp; Evans, William J

    2016-03-30

    The reactivity of the recently discovered Th(2+) complex [K(18-crown-6)(THF)2][Cp″3Th], 1 [Cp'' = C5H3(SiMe3)2-1,3], with hydrogen reagents has been investigated and found to provide syntheses of new classes of thorium hydride compounds. Complex 1 reacts with [Et3NH][BPh4] to form the terminal Th(4+) hydride complex Cp″3ThH, 2, a reaction that formally involves a net two-electron reduction. Complex 1 also reacts in the solid state and in solution with H2 to form a mixed-valent bimetallic product, [K(18-crown-6)(Et2O)][Cp″2ThH2]2, 3, which was analyzed by X-ray crystallography, electron paramagnetic resonance and optical spectroscopy, and density functional theory. The existence of 3, which formally contains Th(3+) and Th(4+), suggested that KC8 could reduce [(C5Me5)2ThH2]2. In the presence of 18-crown-6, this reaction forms an analogous mixed-valent product formulated as [K(18-crown-6)(THF)][(C5Me5)2ThH2]2, 4. A similar complex with (C5Me4H)(1-) ligands was not obtained, but reaction of (C5Me4H)3Th with H2 in the presence of KC8 and 2.2.2-cryptand at -45 °C produced two monometallic hydride products, namely, (C5Me4H)3ThH, 5, and [K(2.2.2-cryptand)]{(C5Me4H)2[η(1):η(5)-C5Me3H(CH2)]ThH]}, 6. Complex 6 contains a metalated tetramethylcyclopentadienyl dianion, [C5Me3H(CH2)](2-), that binds in a tuck-in mode.

  3. Root-Crown Relations of Young Sugar Maple and Yellow Birch

    Treesearch

    Carl H. Tubbs

    1977-01-01

    Young forest-grown sugar maple and yellow birch (1 to 6 inches d.b.h.) crowns were mapped and roots excavated. Crown dimensions were compared. Sugar maple roots usually terminated within a few feet of the crown perimeter. Yellow birch roots frequently terminated well outside crown perimeters and roots of birch were more irregularly distributed than those of maple....

  4. Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining.

    PubMed

    Contreras, Edwin Fernando Ruiz; Henriques, Guilherme Elias Pessanha; Giolo, Suely Ruiz; Nobilo, Mauro Antonio Arruda

    2002-11-01

    Titanium has been suggested as a replacement for alloys currently used in single-tooth restorations and fixed partial dentures. However, difficulties in casting have resulted in incomplete margins and discrepancies in marginal fit. This study evaluated and compared the marginal fit of crowns fabricated from a commercially pure titanium (CP Ti) and from Ti-6Al-4V alloy with crowns fabricated from a Pd-Ag alloy that served as a control. Evaluations were performed before and after marginal refinement by electrical discharge machining (EDM). Forty-five bovine teeth were prepared to receive complete cast crowns. Stone and copper-plated dies were obtained from impressions. Fifteen crowns were cast with each alloy (CP Ti, Ti-6Al-4V, and Pd-Ag). Marginal fit measurements (in micrometers) were recorded at 4 reference points on each casting with a traveling microscope. Marginal refinement with EDM was conducted on the titanium-based crowns, and measurements were repeated. Data were analyzed with the Kruskal-Wallis test, paired t test, and independent t test at a 1% probability level. The Kruskal-Wallis test showed significant differences among mean values of marginal fit for the as-cast CP Ti crowns (mean [SD], 83.9 [26.1] microm) and the other groups: Ti-6Al-4V (50.8 [17.2] microm) and Pd-Ag (45.2 [10.4] microm). After EDM marginal refinement, significant differences were detected among the Ti-6Al-4V crowns (24.5 [10.9] microm) and the other 2 groups: CP Ti (50.6 [20.0] microm) and Pd-Ag (not modified by EDM). Paired t test results indicated that marginal refinement with EDM effectively improved the fit of CP Ti crowns (from 83.9 to 50.6 microm) and Ti-6Al-4V crowns (from 50.8 to 24.5 microm). However, the difference in improvement between the two groups was not significant by t test. Within the limitations of this study, despite the superior results for Ti-6Al-4V, both groups of titanium-based crowns had clinically acceptable marginal fits. After EDM marginal refinement, the fit of cast CP Ti and Ti-6Al-4V crowns improved significantly.

  5. Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns.

    PubMed

    Kwon, Taek-Ka; Pak, Hyun-Soon; Yang, Jae-Ho; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun; Yeo, In-Sung

    2013-05-01

    All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. THE MEAN FRACTURE STRENGTHS WERE AS FOLLOWS: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.

  6. Size-Independent Exciton Localization Efficiency in Colloidal CdSe/CdS Core/Crown Nanosheet Type-I Heterostructures.

    PubMed

    Li, Qiuyang; Wu, Kaifeng; Chen, Jinquan; Chen, Zheyuan; McBride, James R; Lian, Tianquan

    2016-03-22

    CdSe/CdS core/crown nanoplatelet type I heterostructures are a class of two-dimensional materials with atomically precise thickness and many potential optoelectronic applications. It remains unclear how the precise thickness and lack of energy disorder affect the properties of exciton transport in these materials. By steady-state photoluminescence excitation spectroscopy and ultrafast transient absorption spectroscopy, we show that in five CdSe/CdS core/crown structures with the same core and increasing crown size (with thickness of ∼1.8 nm, width of ∼11 nm, and length from 20 to 40 nm), the crown-to-core exciton localization efficiency is independent of crown size and increases with photon energy above the band edge (from 70% at 400 nm to ∼100% at 370 nm), while the localization time increases with the crown size. These observations can be understood by a model that accounts for the competition of in-plane exciton diffusion and selective hole trapping at the core/crown interface. Our findings suggest that the exciton localization efficiency can be further improved by reducing interfacial defects.

  7. NANOSENSOR FOR DETECTION OF SAXITOXIN

    EPA Science Inventory

    For the past several years, we have been investigating a class of crown ethers having a pendant fluorophore for the detection of saxitoxin (Figure 1).1-3 We have investigated several aromatic groups for the fluorescence response, including the anthracene,1,2...

  8. Tested Demonstrations.

    ERIC Educational Resources Information Center

    Gilbert, George L., Ed.

    1980-01-01

    Two demonstrations are described: (1) a variant of preparing purple benzene by phase transfer catalysis with quaternary ammonium salts and potassium permanganate in which crown ethers are used; (2) a corridor or "hallway" demonstration in which unknown molecular models are displayed and prizes awarded to students correctly identifying the…

  9. Clinical examination of leucite-reinforced glass-ceramic crowns (Empress) in general practice: a retrospective study.

    PubMed

    Sjögren, G; Lantto, R; Granberg, A; Sundström, B O; Tillberg, A

    1999-01-01

    The purpose of this study was to retrospectively evaluate leucite reinforced-glass ceramic crowns (Empress) placed in patients who regularly visit general practices. One hundred ten Empress crowns, placed in 29 patients who visited a general practice on a regular basis, were evaluated according to the California Dental Association's (CDA) quality evaluation system. In addition, the occurrence of plaque and certain gingival conditions was evaluated. All crowns were luted with resin composite cement. The mean and median years in function for the crowns were 3.6 and 3.9 years, respectively. Based on the CDA criteria, 92% of the 110 crowns were rated "satisfactory." Eighty-six percent were given the CDA rating "excellent" for margin integrity. Fracture was registered in 6% of the 110 crowns. Of the remaining 103 crowns, the CDA rating excellent was given to 74% for anatomic form, 86% for color, and 90% for surface. No significant differences (P > 0.05) were observed regarding fracture rates between anterior and posterior crowns. With regard to the occurrence of plaque and bleeding on probing, no significant differences (P > 0.05) were observed between the Empress crowns and the controls. Most of the fractured crowns had been placed on molars or premolars. Although the difference between anterior and posterior teeth was not statistically significant with respect to the fracture rates obtained, the number of fractured crowns placed on posterior teeth exceeded that of those placed on anterior teeth. The difference between the fracture rates may have clinical significance, and the risk of fracture has to be taken into consideration when placing crowns on teeth that are likely to be subjected to high stress levels.

  10. Solution behavior of iron(III) and iron(II) porphyrins in DMSO and reaction with superoxide. Effect of neighboring positive charge on thermodynamics, kinetics and nature of iron-(su)peroxo product.

    PubMed

    Duerr, K; Troeppner, O; Olah, J; Li, J; Zahl, A; Drewello, T; Jux, N; Harvey, J N; Ivanović-Burmazović, I

    2012-01-14

    The solution behavior of iron(III) and iron(II) complexes of 5(4),10(4),15(4),20(4)-tetra-tert-butyl-5,10,15,20-tetraphenylporphyrin (H(2)tBuTPP) and the reaction with superoxide (KO(2)) in DMSO have been studied in detail. Applying temperature and pressure dependent NMR studies, the thermodynamics of the low-spin/high-spin equilibrium between bis- and mono-DMSO Fe(II) forms have been quantified (K(DMSO) = 0.082 ± 0.002 at 298.2 K, ΔH° = +36 ± 1 kJ mol(-1), ΔS° = +101 ± 4 J K(-1) mol(-1), ΔV° = +16 ± 2 cm(3) mol(-1)). This is a key activation step for substitution and inner-sphere electron transfer. The superoxide binding constant to the iron(II) form of the studied porphyrin complex was found to be (9 ± 0.5) × 10(3) M(-1), and does not change significantly in the presence of the externally added crown ether in DMSO (11 ± 4) × 10(3) M(-1). The rate constants for the superoxide binding (k(on) = (1.30 ± 0.01) × 10(5) M(-1) s(-1)) and release (k(off) = 11.6 ± 0.7 s(-1)) are not affected by the presence of the external crown ether in solution. The resulting iron(II)-superoxide adduct has been characterized (mass spectrometry, EPR, high-pressure UV/Vis spectroscopy) and upon controlled addition of a proton source it regenerates the starting iron(II) complex. Based on DFT calculations, the reaction product without neighboring positive charge has iron(II)-superoxo character in both high-spin side-on and low-spin end-on forms. The results are compared to those obtained for the analogous complex with covalently attached crown ether, and more general conclusions regarding the spin-state equilibrium of iron(II) porphyrins, their reaction with superoxide and the electronic structure of the product species are drawn.

  11. Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

    PubMed Central

    Kwon, Taek-Ka; Pak, Hyun-Soon; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun

    2013-01-01

    PURPOSE All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS The mean fracture strengths were as follows: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain. PMID:23755332

  12. Genetic variation in tree structure and its relation to size in Douglas-fir: II. crown form, branch characters, and foliage characters.

    Treesearch

    J.B. St. Clair

    1994-01-01

    Genetic variation and covariation among traits of tree size and structure were assessed in an 18-year-old Douglas-fir (Pseudotsuga menziesii var. menziesii (Mirb.) Franco) genetic test in the Coast Range of Oregon. Considerable genetic variation was found for relative crown width; stem increment per crown projection area; leaf...

  13. Calixarene crown ether solvent composition and use thereof for extraction of cesium from alkaline waste solutions

    DOEpatents

    Moyer, Bruce A.; Sachleben, Richard A.; Bonnesen, Peter V.; Presley, Derek J.

    2001-01-01

    A solvent composition and corresponding method for extracting cesium (Cs) from aqueous neutral and alkaline solutions containing Cs and perhaps other competing metal ions is described. The method entails contacting an aqueous Cs-containing solution with a solvent consisting of a specific class of lipophilic calix[4]arene-crown ether extractants dissolved in a hydrocarbon-based diluent containing a specific class of alkyl-aromatic ether alcohols as modifiers. The cesium values are subsequently recovered from the extractant, and the solvent subsequently recycled, by contacting the Cs-containing organic solution with an aqueous stripping solution. This combined extraction and stripping method is especially useful as a process for removal of the radionuclide cesium-137 from highly alkaline waste solutions which are also very concentrated in sodium and potassium. No pre-treatment of the waste solution is necessary, and the cesium can be recovered using a safe and inexpensive stripping process using water, dilute (millimolar) acid solutions, or dilute (millimolar) salt solutions. An important application for this invention would be treatment of alkaline nuclear tank wastes. Alternatively, the invention could be applied to decontamination of acidic reprocessing wastes containing cesium-137.

  14. Homopolyrotaxanes and Homopolyrotaxane Networks of PEO

    NASA Technical Reports Server (NTRS)

    Pugh, Coleen; Mattice, Wayne

    2005-01-01

    In order to identify the optimum size of macrocrown ether for threading, we first investigated the size and shape of simple crown ethers in the melt at 373 K, and their extent of threading with PEO in the melt using coarse-grained Monte Carlo simulations on the 2nnd (second nearest neighbor diamond) lattice, which is a high coordination lattice whose coarse-grained chains can be reverse mapped into fully atomistic models in continuous space.

  15. Trivalent Lewis Acidic Cations Govern the Electronic Properties and Stability of Heterobimetallic Complexes of Nickel.

    PubMed

    Kumar, Amit; Lionetti, Davide; Day, Victor W; Blakemore, James D

    2018-01-02

    Assembly of heterobimetallic complexes is synthetically challenging due to the propensity of ditopic ligands to bind metals unselectively. Here, we employ a novel divergent approach for selective preparation of a variety of bimetallic complexes within a ditopic macrocyclic ligand platform. In our approach, nickel is readily coordinated to a Schiff base cavity, and then a range of redox-inactive cations (M=Na + , Ca 2+ , Nd 3+ , and Y 3+ ) are installed in a pendant crown-ether-like site. This modular strategy allows access to complexes with the highly Lewis acidic trivalent cations Nd 3+ and Y 3+ , a class of compounds that were previously inaccessible. Spectroscopic and electrochemical studies reveal wide variations in properties that are governed most strongly by the trivalent cations. Exposure to dimethylformamide drives loss of Nd 3+ and Y 3+ from the pendant crown-ether site, suggesting solvent effects must be carefully considered in future applications involving use of highly Lewis acidic metals. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Stable divalent germanium, tin and lead amino(ether)-phenolate monomeric complexes: structural features, inclusion heterobimetallic complexes, and ROP catalysis.

    PubMed

    Wang, Lingfang; Roşca, Sorin-Claudiu; Poirier, Valentin; Sinbandhit, Sourisak; Dorcet, Vincent; Roisnel, Thierry; Carpentier, Jean-François; Sarazin, Yann

    2014-03-21

    Stable germanium(II) and lead(II) amido complexes {LO(i)}M(N(SiMe3)2) (M = Ge(II), Pb(II)) bearing amino(ether)phenolate ligands are readily available using the proteo-ligands {LO(i)}H of general formula 2-CH2NR2-4,6-tBu2-C6H2OH (i = 1, NR2 = N((CH2)2OCH3)2; i = 2, NR2 = NEt2; i = 3, NR2 = aza-15-crown-5) and M(N(SiMe3)2)2 precursors. The molecular structures of these germylenes and plumbylenes, as well as those of {LO(3)}GeCl, {LO(3)}SnCl and of the congeneric {LO(4)}Sn(II)(N(SiMe3)2) where NR2 = aza-12-crown-4, have been determined crystallographically. All complexes are monomeric, with 3-coordinate metal centres. The phenolate systematically acts as a N^O(phenolate) bidentate ligand, with no interactions between the metal and the O(side-arm) atoms in these cases (for {LO(1)}(-), {LO(3)}(-) and {LO(4)}(-)) where they could potentially arise. For each family, the lone pair of electrons essentially features ns(2) character, and there is little, if any, hybridization of the valence orbitals. Heterobimetallic complexes {LO(3)}M(N(SiMe3)2)·LiOTf, where the Li(+) cation sits inside the tethered crown-ether, were prepared by reaction of {LO(3)}M(N(SiMe3)2) and LiOTf (M = Ge(II), Sn(II)). The inclusion of Li(+) (featuring a close contact with the triflate anion) in the macrocycle bears no influence on the coordination sphere of the divalent tetrel element. In association with iPrOH, the amido germylenes, stannylenes and plumbylenes catalyse the controlled polymerisation of L- and racemic lactide. The activity increases linearly according to Ge(II) ≪ Sn(II) ≪ Pb(II). The simple germylenes generate very sluggish catalysts, but the activity is significantly boosted if the heterobimetallic complex {LO(3)}Ge(N(SiMe3)2)·LiOTf is used instead. On the other hand, with 10-25 equiv. of iPrOH, the plumbylenes afford highly active binary catalysts, converting 1000 or 5000 equiv. of monomer at 60 °C within 3 or 45 min, respectively, in a controlled fashion.

  17. Pressure-assisted introduction of urine samples into a short capillary for electrophoretic separation with contactless conductivity and UV spectrometry detection.

    PubMed

    Makrlíková, Anna; Opekar, František; Tůma, Petr

    2015-08-01

    A computer-controlled hydrodynamic sample introduction method has been proposed for short-capillary electrophoresis. In the method, the BGE flushes sample from the loop of a six-way sampling valve and is carried to the injection end of the capillary. A short pressure impulse is generated in the electrolyte stream at the time when the sample zone is at the capillary, leading to injection of the sample into the capillary. Then the electrolyte flow is stopped and the separation voltage is turned on. This way of sample introduction does not involve movement of the capillary and both of its ends remain constantly in the solution during both sample injection and separation. The amount of sample introduced to the capillary is controlled by the duration of the pressure pulse. The new sample introduction method was tested in the determination of ammonia, creatinine, uric acid, and hippuric acid in human urine. The determination was performed in a capillary with an overall length of 10.5 cm, in two BGEs with compositions 50 mM MES + 5 mM NaOH (pH 5.1) and 1 M acetic acid + 1.5 mM crown ether 18-crown-6 (pH 2.4). A dual contactless conductivity/UV spectrometric detector was used for the detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Clinical evaluation of fiber-reinforced composite crowns in pulp-treated primary molars: 12-month results

    PubMed Central

    Mohammadzadeh, Zahra; Parisay, Iman; Mehrabkhani, Maryam; Madani, Azam Sadat; Mazhari, Fatemeh

    2016-01-01

    Objective: The aim of this study was to evaluate the clinical performance of tooth-colored fiber-reinforced composite (FRC) crowns in pulp-treated second primary mandibular teeth. Materials and Methods: This split-mouth randomized, clinical trial performed on 67 children between 3 and 6 years with two primary mandibular second molars requiring pulp treatment. After pulp therapy, the teeth were randomly assigned to stainless steel crown (SSC) or FRC crown groups. Modified United States Public Health Service criteria were used to evaluate marginal integrity, marginal discoloration, and secondary caries in FRC crowns at intervals of 3, 6, and 12 months. Retention rate and gingival health were also compared between the two groups. The data were analyzed using Friedman, Cochran, and McNemar's tests at a significance level of 0.05. Results: Intact marginal integrity in FRC crowns at 3, 6, and 12 months were 93.2%, 94.8%, and 94.2%, respectively. Marginal discoloration and secondary caries were not found at any of the FRC crowns. The retention rates of the FRC crowns were 100%, 98.3%, and 89.7% at 3, 6 and 12 months, respectively, whereas all the SSCs were found to be present and intact after 12 months (P = 0.016). There was no statistically significant difference between the two groups in gingival health. Conclusion: According to the results of this study, it seems that when esthetics is a concern, in cooperative patients with good oral hygiene, FRC crowns can be considered as a valuable procedure. PMID:28042269

  19. Piezoresistive microcantilever based lab-on-a-chip system for detection of macronutrients in the soil

    NASA Astrophysics Data System (ADS)

    Patkar, Rajul S.; Ashwin, Mamta; Rao, V. Ramgopal

    2017-12-01

    Monitoring of soil nutrients is very important in precision agriculture. In this paper, we have demonstrated a micro electro mechanical system based lab-on-a-chip system for detection of various soil macronutrients which are available in ionic form K+, NO3-, and H2PO4-. These sensors are highly sensitive piezoresistive silicon microcantilevers coated with a polymer matrix containing methyltridodecylammonium nitrate ionophore/ nitrate ionophore VI for nitrate sensing, 18-crown-6 ether for potassium sensing and Tributyltin chloride for phosphate detection. A complete lab-on-a-chip system integrating a highly sensitive current excited Wheatstone's bridge based portable electronic setup along with arrays of microcantilever devices mounted on a printed circuit board with a liquid flow cell for on the site experimentation for soil test has been demonstrated.

  20. A preliminary study on the short-term efficacy of chairside computer-aided design/computer-assisted manufacturing- generated posterior lithium disilicate crowns.

    PubMed

    Reich, Sven; Fischer, Sören; Sobotta, Bernhard; Klapper, Horst-Uwe; Gozdowski, Stephan

    2010-01-01

    The purpose of this preliminary study was to evaluate the clinical performance of chairside-generated crowns over a preliminary time period of 24 months. Forty-one posterior crowns made of a machinable lithium disilicate ceramic for full-contour crowns were inserted in 34 patients using a chairside computer-aided design/computer-assisted manufacturing technique. The crowns were evaluated at baseline and after 6, 12, and 24 months according to modified United States Public Health Service criteria. After 2 years, all reexamined crowns (n = 39) were in situ; one abutment exhibited secondary caries and two abutments received root canal treatment. Within the limited observation period, the crowns revealed clinically satisfying results.

  1. Fracture rates of IPS Empress all-ceramic crowns--a systematic review.

    PubMed

    Heintze, Siegward D; Rousson, Valentin

    2010-01-01

    The aim of this study was to evaluate the clinical fracture rate of crowns fabricated with the pressable, leucite-reinforced ceramic IPS Empress, and relate the results to the type of tooth restored. The database SCOPUS was searched for clinical studies involving full-coverage crowns made of IPS Empress. To assess the fracture rate of the crowns in relation to the type of restored tooth and study, Poisson regression analysis was used. Seven clinical studies were identified involving 1,487 adhesively luted crowns (mean observation time: 4.5+/-1.7 years) and 81 crowns cemented with zinc-phosphate cement (mean observation time: 1.6+/-0.8 years). Fifty-seven of the adhesively luted crowns fractured (3.8%). The majority of fractures (62%) occurred between the third and sixth year after placement. There was no significant influence regarding the test center on fracture rate, but the restored tooth type played a significant role. The hazard rate (per year) for crowns was estimated to be 5 in every 1,000 crowns for incisors, 7 in every 1,000 crowns for premolars, 12 in every 1,000 crowns for canines, and 16 in every 1,000 crowns for molars. One molar crown in the zinc-phosphate group fractured after 1.2 years. Adhesively luted IPS Empress crowns showed a low fracture rate for incisors and premolars and a somewhat higher rate for molars and canines. The sample size of the conventionally luted crowns was too small and the observation period too short to draw meaningful conclusions.

  2. Factors affecting the shear bond strength of metal and ceramic brackets bonded to different ceramic surfaces.

    PubMed

    Abu Alhaija, Elham S J; Abu AlReesh, Issam A; AlWahadni, Ahed M S

    2010-06-01

    The aims of this study were to evaluate the shear bond strength (SBS) of metal and ceramic brackets bonded to two different all-ceramic crowns, IPS Empress 2 and In-Ceram Alumina, to compare the SBS between hydrofluoric acid (HFA), phosphoric acid etched, and sandblasted, non-etched all-ceramic surfaces. Ninety-six all-ceramic crowns were fabricated resembling a maxillary left first premolar. The crowns were divided into eight groups: (1) metal brackets bonded to sandblasted 9.6 per cent HFA-etched IPS Empress 2 crowns; (2) metal brackets bonded to sandblasted 9.6 per cent HFA-etched In-Ceram crowns; (3) ceramic brackets bonded to sandblasted 9.6 per cent HFA-etched IPS Empress 2 crowns; (4) ceramic brackets bonded to sandblasted 9.6 per cent HFA-etched In-Ceram crowns; (5) metal brackets bonded to sandblasted 37 per cent phosphoric acid-etched IPS Empress 2 crowns; (6) metal brackets bonded to sandblasted 37 per cent phosphoric acid-etched In-Ceram crowns; (7) metal brackets bonded to sandblasted, non-etched IPS Empress 2 crowns; and (8) metal brackets bonded to sandblasted, non-etched In-Ceram crowns. Metal and ceramic orthodontic brackets were bonded using a conventional light polymerizing adhesive resin. An Instron universal testing machine was used to determine the SBS at a crosshead speed of 0.1 mm/minute. Comparison between groups was performed using a univariate general linear model and chi-squared tests. The highest mean SBS was found in group 3 (120.15 +/- 45.05 N) and the lowest in group 8 (57.86 +/- 26.20 N). Of all the variables studied, surface treatment was the only factor that significantly affected SBS (P < 0.001). Acid etch application to sandblasted surfaces significantly increased the SBS in groups 1, 2, 5, and 6. The SBS of metal brackets debonded from groups 1, 3, and 5 were not significantly different from those of groups 2, 4, and 6. All debonded metal brackets revealed a similar pattern of bond failure at the adhesive-restorative interface. However, ceramic brackets had a significantly different adhesive failure pattern with dominant failure at the adhesive-bracket interface. Ceramic fractures after bracket removal were found more often in groups 1-4. No significant difference in ceramic fracture was observed between the IPS Empress 2 and In-Ceram groups.

  3. Luminescence, electrochemistry and host-guest properties of dinuclear platinum(ii) terpyridyl complexes of sulfur-containing bridging ligands.

    PubMed

    Tang, Rowena Pui-Ling; Wong, Keith Man-Chung; Zhu, Nianyong; Yam, Vivian Wing-Wah

    2009-05-28

    A series of dinuclear platinum(ii) terpyridyl and terpyridyl-crown complexes with 2,2-dicyano-1,1-ethylenedithiolate (i-mnt), 1,3-benzenedithiolate (SC(6)H(4)S-1,3) and N,N-diethyldithiocarbamate (dtc) bridging ligands have been synthesized and characterized. Their photophysical and electrochemical properties, together with that of the related mononuclear platinum(ii) terpyridyl-crown complex and its crown-free analogue, have been studied. The ion-binding properties of the terpyridyl-crown complexes have been determined by electronic absorption spectroscopy and ESI-mass spectrometry. The X-ray crystal structures of [Pt(trpyC[triple bond, length as m-dash]C-benzo-15-crown-5)Cl]PF(6), [{Pt(trpy)}(2)(micro-SC(6)H(4)S-1,3)](PF(6))(2) and [{Pt(trpy)}(2){micro-(i-mnt)}](PF(6))(2) have also been determined.

  4. A short-term clinical evaluation of IPS Empress 2 crowns.

    PubMed

    Toksavul, Suna; Toman, Muhittin

    2007-01-01

    The aim of this study was to evaluate the clinical performance of all-ceramic crowns made with the IPS Empress 2 system after an observation period of 12 to 60 months. Seventy-nine IPS Empress 2 crowns were placed in 21 patients. The all-ceramic crowns were evaluated clinically, radiographically, and using clinical photographs. The evaluations took place at baseline (2 days after cementation) and at 6-month intervals for 12 to 60 months. Survival rate of the crowns was determined using Kaplan-Meier statistical analysis. Based on the US Public Health Service criteria, 95.24% of the crowns were rated satisfactory after a mean follow-up period of 58 months. Fracture was registered in only 1 crown. One endodontically treated tooth failed as a result of fracture at the cervical margin area. In this in vivo study, IPS Empress 2 crowns exhibited a satisfactory clinical performance during an observation period ranging from 12 to 60 months.

  5. DFT calculation and experimental validation on the interactions of bis(trifluoromethylsulfonyl)imide and hexafluorophosphate with cesium

    NASA Astrophysics Data System (ADS)

    Sun, Taoxiang; Duan, Wuhua; Wang, Yaxing; Hu, Shaowen; Wang, Shuao; Chen, Jing; Shen, Xinghai

    2017-11-01

    Bis(trifluoromethylsulfonyl)imide (NTf2-) and hexafluorophosphate (PF6-) are the most frequently used anions for hydrophobic ionic liquids (ILs) which have been considered as promising solvents in the extraction of cesium ions. The interactions of NTf2- and PF6- with Cs+ were explored in this work. The results of DFT calculation indicated that both Cs+ and Cs(18C6)+ prefer to interact with two NTf2- or PF6- anions in gas phase, where 18C6 is 18-crown-6. The complex of Cs(NTf2)2- was observed in electrospray ionization mass spectrometry (ESI-MS), and the complexes of [Cs(18C6)NTf2]2 and [Cs(18C6)PF6]2 were crystallized in which Cs(18C6)+ interacted with two anions. The interactions of NTf2- with cesium resulted in a synergistic effect between dicyclohexano-18-crown-6 (DCH18C6) and NTf2- in the extraction of Cs+ using n-octanol as diluent. However, DFT calculation revealed that the complex Cs(DCH18C6)+ interacted with one NTf2- anion was more thermodynamically stable than that with two anions in organic phase, different from that in gas phase.

  6. Unsupervised individual tree crown detection in high-resolution satellite imagery

    DOE PAGES

    Skurikhin, Alexei N.; McDowell, Nate G.; Middleton, Richard S.

    2016-01-26

    Rapidly and accurately detecting individual tree crowns in satellite imagery is a critical need for monitoring and characterizing forest resources. We present a two-stage semiautomated approach for detecting individual tree crowns using high spatial resolution (0.6 m) satellite imagery. First, active contours are used to recognize tree canopy areas in a normalized difference vegetation index image. Given the image areas corresponding to tree canopies, we then identify individual tree crowns as local extrema points in the Laplacian of Gaussian scale-space pyramid. The approach simultaneously detects tree crown centers and estimates tree crown sizes, parameters critical to multiple ecosystem models. Asmore » a demonstration, we used a ground validated, 0.6 m resolution QuickBird image of a sparse forest site. The two-stage approach produced a tree count estimate with an accuracy of 78% for a naturally regenerating forest with irregularly spaced trees, a success rate equivalent to or better than existing approaches. In addition, our approach detects tree canopy areas and individual tree crowns in an unsupervised manner and helps identify overlapping crowns. Furthermore, the method also demonstrates significant potential for further improvement.« less

  7. Unsupervised individual tree crown detection in high-resolution satellite imagery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skurikhin, Alexei N.; McDowell, Nate G.; Middleton, Richard S.

    Rapidly and accurately detecting individual tree crowns in satellite imagery is a critical need for monitoring and characterizing forest resources. We present a two-stage semiautomated approach for detecting individual tree crowns using high spatial resolution (0.6 m) satellite imagery. First, active contours are used to recognize tree canopy areas in a normalized difference vegetation index image. Given the image areas corresponding to tree canopies, we then identify individual tree crowns as local extrema points in the Laplacian of Gaussian scale-space pyramid. The approach simultaneously detects tree crown centers and estimates tree crown sizes, parameters critical to multiple ecosystem models. Asmore » a demonstration, we used a ground validated, 0.6 m resolution QuickBird image of a sparse forest site. The two-stage approach produced a tree count estimate with an accuracy of 78% for a naturally regenerating forest with irregularly spaced trees, a success rate equivalent to or better than existing approaches. In addition, our approach detects tree canopy areas and individual tree crowns in an unsupervised manner and helps identify overlapping crowns. Furthermore, the method also demonstrates significant potential for further improvement.« less

  8. Holographic evaluation of the marginal fits of complete crowns loaded at the central fossa

    NASA Astrophysics Data System (ADS)

    Chen, Terry Y.; Chang, Guan L.; Wu, Shih H.

    1995-05-01

    In dentistry, a defect of cementation on the margins of crowns accumulates bacterial plaque easily. This can result in recurrent caries and periodontal disease. In this paper holographic interferometry was applied to evaluate the effect of masticatory force on various complete crowns. Four complete molar crowns made from different materials (Au alloy, Pd-Ag alloy, Ni-Cr alloy, and porcelain fused to metal) were tested. The out-of-plane displacements of the crown specimens were measured by the method of multiple observations. The displacements measured range from 6 to 10 micrometers under normal load (25 N). However, the marginal openings of all four crowns were estimated to be less than 0.2 micrometers . In addition the defect of the crown was examined.

  9. 76 FR 19188 - Joint Biomedical Laboratory Research and Development and Clinical Science Research and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-06

    .../Silver Spring. Neurobiology-E June 3, 2011 Crowne Plaza DC/Silver Spring. Pulmonary Medicine June 3, 2011 Crowne Plaza DC/Silver Spring. Cellular & Molecular Medicine........ June 6, 2011 Crowne Plaza DC/Silver...

  10. Determination of volatile corrosion inhibitors by capillary electrophoresis.

    PubMed

    Pereira, Elisabete A; Tavares, Marina F M

    2004-10-08

    In this work, a capillary electrophoresis (CE) method using indirect UV detection (214nm) for the simultaneous determination of monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), diethylethanolamine (DEEA), monocyclohexylamine (MCHA) and dicyclohexylamine (DCHA) in water/ethanol extracts of wrapping materials containing volatile corrosion inhibitors (VCIs) was described. A running buffer consisting of 0.010 molL(-1) imidazole, 0.010 molL(-1) 2-hydroxyisobutyric acid (HIBA) and 0.010 molL(-1) 18-crown-6 ether enabled separation of the analytes in less than 7 min. A few method validation parameters were determined revealing good migration time repeatability (<0.7% RSD) and area repeatability (< 1.8% RSD). Limits of detection were in the range of 0.52-1.54 mg L(-1). Recovery values were in the range of 94.8-100.9%. The methodology was successfully applied to the analysis of three commercial products (VCI treated paper, foam and plastic). The concentration of amines in these materials varied from 0.050 to 22.3% (w/w).

  11. Nuclear chemistry research and spectroscopy with radioactive sources. Sixteenth annual progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fink, R.W.

    1980-10-31

    Nuclear spectroscopic studies included the decay of /sup 201/Po to /sup 201/Bi, decay of /sup 201/At, decay of /sup 187/Au, and g/sub 7/2/ intruder band in /sup 109/Ag. A systematic comparison was conducted of the Interacting Boson-Fermion Approximation model predictions with experiment on neutron-deficient odd-A gold isotopes. An international comparison of /sup 133/Ba ..gamma..-ray standards was completed. L/sub 1/, L/sub 2/, and L/sub 3/ subshells were studied, and the decay energy of /sup 207/Bi is being measured. Carrier-free /sup 18/F has been prepared in crown ether solution. (DLC)

  12. A prospective 10-year study of metal ceramic single crowns and fixed dental prosthesis retainers in private practice settings.

    PubMed

    Reitemeier, Bernd; Hänsel, Kristina; Kastner, Christian; Weber, Anke; Walter, Michael H

    2013-03-01

    Metal ceramic restorations are widely used in prosthodontics, but long-term data on their clinical performance in private practice settings based on prospective trials are sparse. This clinical trial was designed to provide realistic long-term survival rates for different outcomes related to tooth loss, crown loss, and metal ceramic defect. Ninety-five participants were provided with 190 noble metal ceramic single crowns and 138 participants with 276 fixed dental prosthesis retainer crowns on vital posterior teeth. Follow-up examinations were scheduled 2 weeks after insertion, annually up to 8 years, and after 10 years. Kaplan-Meier survival analyses, Mantel-Cox logrank tests, and Cox regression analyses were conducted. Because of variations in the time of the last examinations, the maximum observation period was 12.1 years. For the primary outcome 'loss of crown or tooth', the Kaplan-Meier survival rate was 94.3% ±1.8% (standard error) at 8.0 years (last outcome event) for single crowns and 94.4% ±1.5% at 11.0 years for fixed dental prosthesis retainer crowns. The difference between the survival functions was not significant (P>.05). For the secondary outcome 'metal ceramic defect', the survival rate was 88.8% ±3.2% at 11.0 years for single crowns and 81.7% ±3.5% at 11.0 years for fixed dental prosthesis retainer crowns. In Cox regression models, the only significant covariates for the outcome event 'metal ceramic defect' were bruxism in the medical history (single crowns) and signs and symptoms of bruxism (fixed dental prosthesis retainer crowns) with hazard ratios of 3.065 (95% CI 1.063 - 8.832) and 2.554 (95% CI 1.307 - 4.992). Metal ceramic crowns provided in private practice settings show good longevity. Bruxism appears to indicate a risk for metal ceramic defects. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  13. Comparison of fracture resistance and fracture characterization of bilayered zirconia/fluorapatite and monolithic lithium disilicate all ceramic crowns.

    PubMed

    Altamimi, Abdulaziz M; Tripodakis, Aris Petros; Eliades, George; Hirayama, Hiroshi

    2014-01-01

    To compare the fracture resistance between bilayered zirconia/ fluorapatite and monolithic lithium disilicate heat-pressed crowns and characterize the mode of fracture failure. Thirty crown samples were sequentially fitted on a mandibular right first molar metal replica of an ivory prepared molar tooth. The crown specimens were divided in three groups (A, B, and C; n = 10 for each group). Group A consisted of bilayered zirconia/fluorhapatite pressed-over crowns with standard design crown copings (0.7 mm uniform thickness), Group B of bilayered zirconia/fluorhapatite with anatomical design crown copings, and Group C of lithium disilicate monolithic crowns. The samples were then dynamically loaded under water for 100,000 cycles with a profile of 250 N maximum load at 1,000 N/s rate and 2.0 Hz frequency. Loading was performed with a steel ball (5 mm in diameter) coming into contact with the test crown, loading to maximum, holding for 0.2 s, unloading and lifting off 0.5 mm. The samples were then fractured under static loading, in order to determine the ultimate crown strength. Analysis of the recorded fracture load values was carried out with one-way analysis of variance (ANOVA) followed by Tukey tests. Fractured specimens were examined by stereomicroscopy and scanning electron microscopy. The fracture loads measured were (N, means and standard deviations): Group A: 561.87 (72.63), Group B: 1,014.16 (70.18) and Group C: 1,360.63 (77.95). All mean differences were statistically significant (P < 0.001). Catastrophic fractures occurred in Group C, whereas mainly veneer fractures were observed in Groups A and B. In the present study, the heat-pressed monolithic lithium-disilicate crowns showed more fracture resistance than zirconia/fluorapatite pressed-over crowns. Within the bilayered groups, the anatomical zirconia coping design presented increased ceramic fracture resistance.

  14. Extracting oil palm crown from WorldView-2 satellite image

    NASA Astrophysics Data System (ADS)

    Korom, A.; Phua, M.-H.; Hirata, Y.; Matsuura, T.

    2014-02-01

    Oil palm (OP) is the most commercial crop in Malaysia. Estimating the crowns is important for biomass estimation from high resolution satellite (HRS) image. This study examined extraction of individual OP crown from a WorldView-2 image using twofold algorithms, i.e., masking of Non-OP pixels and detection of individual OP crown based on the watershed segmentation of greyscale images. The study site was located in Beluran district, central Sabah, where matured OPs with the age ranging from 15 to 25 years old have been planted. We examined two compound vegetation indices of (NDVI+1)*DVI and NDII for masking non-OP crown areas. Using kappa statistics, an optimal threshold value was set with the highest accuracy at 90.6% for differentiating OP crown areas from Non-OP areas. After the watershed segmentation of OP crown areas with additional post-procedures, about 77% of individual OP crowns were successfully detected in comparison to the manual based delineation. Shape and location of each crown segment was then assessed based on a modified version of the goodness measures of Möller et al which was 0.3, indicating an acceptable CSGM (combined segmentation goodness measures) agreements between the automated and manually delineated crowns (perfect case is '1').

  15. Clinical Performance of Pedo Jacket Crowns in Maxillary Anterior Primary Teeth.

    PubMed

    Castro, Aimee; Badr, Sherine B Y; El-Badrawy, Wafa; Kulkarni, Gajanan

    2016-09-15

    To assess the clinical performance of Pedo Jacket crowns for restoration of carious primary anterior teeth. A total of 129 carious primary incisors and canines of 48 children younger than 71 months of age- were restored with Pedo Jacket crowns and resin-modified glass ionomer cementation. They were assessed for: ease of use; presence of recurrent decay; wear; partial or complete loss of the crown; color stability; gingival health; and overall clinical success over a 12-month follow-up. The patient's behavior at the restorative appointment during crown placement was also assessed. An overall clinical success of 89.5 percent of the teeth in 87.3 percent of the children was seen one year later. The crowns were easy to use, even in uncooperative children. The color stability, wear, plaque accumulation, and gingival health were acceptable. Discoloration, wear, or complete loss of the crown were found in 13.1 percent, 5.4 percent, and 7.6 percent of children, respectively. Although not statistically significant, failures were associated with poor patient cooperation at the time of crown placement, poor oral hygiene, or operator error. Pedo Jacket crowns are a viable treatment alternative for carious maxillary primary anterior teeth.

  16. Thermodynamics of formation for the 18-crown-6-triglycine molecular complex in water-dimethylsulfoxide solvents

    NASA Astrophysics Data System (ADS)

    Usacheva, T. R.; Lan, Pham Thi; Sharnin, V. A.

    2014-06-01

    The effect of a water-dimethylsulfoxide (DMSO) solvent on the formation of a molecular complex of 18-crown-6 (18C6) with triglycine (diglycylglycine, 3Gly) is studied via calorimetric titration. It is found that switching from water to an H2O-DMSO mixture with DMSO mole fraction of 0.30 is accompanied by a monotonic increase in the stability of [3Gly18C6] complex, from log K ∘ = 1.10 to log K ∘ = 2.44, and an increase in the exothermicity of the reaction of its formation, from -5.9 to -16.9 kJ/mol. It is shown that the [3Gly18C6] complex exhibits enthalpy stabilization with negative values of enthalpy and entropy over the investigated range of H2O-DMSO solvents. Analysis of the reagents' solvation characteristics reveals that the increase in the reaction's exothermicity of transfer is due to differences in the solvation of [3Gly18C6] and 18C6 with a small solvation contribution from 3Gly. It is concluded that the change in the Gibbs energy of the reaction 3Glysolv + 18C6solv ↔ [3Gly18C6]solv is due to differences in the change in the solvation state of the complex and the peptide (Δtr G ∘([3Gly18C6])-Δtr G ∘(3Gly)).

  17. Selective P4 Activation by a Highly Reduced Cobaltate: Synthesis of Dicobalt Tetraphosphido Complexes.

    PubMed

    Pelties, Stefan; Maier, Thomas; Herrmann, Dirk; de Bruin, Bas; Rebreyend, Christophe; Gärtner, Stefanie; Shenderovich, Ilya G; Wolf, Robert

    2017-05-02

    Although the chemistry of transition metal polyphosphide anions has attracted significant attention, there are few reports of studies in which such species have been synthesized directly from white phosphorus. [K(OEt 2 ) 2 {Co(BIAN)(cod)}] (1, BIAN=1,2-bis(2,6-diisopropylphenylimino)acenaphthene, cod=1,5-cyclooctadiene), which is readily prepared by ligand exchange from [K(thf) x {Co(cod) 2 }], reacts with P 4 to afford [{K(thf)} 2 {(BIAN)Co} 2 (μ-η 4 :η 4 -P 4 )] (2 a) in 61 % yield (isolated product). [{K(OEt 2 )} 2 {(BIAN)Co} 2 (μ-η 4 :η 4 -P 4 )] (2 b) and [K([18]crown-6)(MeCN)] 2 [{(BIAN)Co} 2 (μ-η 4 :η 4 -P 4 )] (2 c) were obtained by recrystallizing 2 a from diethyl ether and acetonitrile (and using [18]crown-6 in case of 2 c). Oxidation of 2 a with [Cp 2 Fe]BAr F 4 (one equivalent) and subsequent recrystallization of the product from different solvents gave [K(OEt 2 ){(BIAN)Co} 2 (μ-η 4 :η 4 -P 4 )] (3 a) and [K(dme) 4 ][{(BIAN)Co} 2 (μ-η 4 :η 4 -P 4 )] (3 b; dme=1,2-dimethoxyethane). Neutral [{(BIAN)Co} 2 (μ-η 4 :η 4 -P 4 )] (4) was obtained in moderate yield by oxidizing 2 a with two equivalents of [Cp 2 Fe]BAr F 4 . The new complexes were characterized by NMR, EPR (in the case of 3 a), and UV/Vis spectroscopy, and elemental analysis. The molecular structures revealed by X-ray crystallography display planar cyclic or open-chain P 4 4- units sandwiched between {(BIAN)Co} fragments. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Zirconia-implant-supported all-ceramic crowns withstand long-term load: a pilot investigation.

    PubMed

    Kohal, Ralf-J; Klaus, Gerold; Strub, Jörg R

    2006-10-01

    The purpose of this pilot investigation was to test whether zirconia implants restored with different all-ceramic crowns would fulfill the biomechanical requirements for clinical use. Therefore, all-ceramic Empress-1 and Procera crowns were cemented on zirconia implants and exposed to the artificial mouth. Afterwards, the fracture strength of the all-ceramic implant-crown systems was evaluated. Conventional titanium implants restored with porcelain-fused-to-metal (PFM) crowns served as controls. Sixteen titanium implants with 16 PFM crowns and 32 zirconia implants with 16 Empress-1 crowns and 16 Procera crowns each--i.e., three implant-crown groups--were used in this investigation. The titanium implants were fabricated using the ReImplant system and the zirconia implants using the Celay system. The upper left central incisor served as a model for the fabrication of the implants and the crowns. Eight samples of each group were submitted to a long-term load test in the artificial mouth (1.2 million chewing cycles). Subsequently, a fracture strength test was performed with seven of the eight crowns. The remaining eight samples of each group were not submitted to the long-term load in the artificial mouth but were fracture-tested immediately. One loaded and one unloaded sample of each group were evaluated regarding the marginal fit of the crowns. All test samples survived the exposure to the artificial mouth. Three Empress-1 crowns showed cracks in the area of the loading steatite ball. The values for the fracture load in the titanium implant-PFM crown group without artificial loading ranged between 420 and 610 N (mean: 531.4 N), between 460 and 570 N (mean: 512.9 N) in the Empress-1 crown group, and in the Procera crown group the values were between 475 and 700 N (mean: 575.7 N) when not loaded artificially. The results when the specimens were loaded artificially with 1.2 million cycles were as follows: the titanium implant-PFM crowns fractured between 440 and 950 N (mean: 668.6 N), the Empress-1 crowns between 290 and 550 N (mean: 410.7 N), and the Procera crowns between 450 and 725 N (mean: 555.5 N). No statistically significant differences could be found among the groups without artificial load. The fracture values for the PFM and the Procera crowns after artificial loading were statistically significantly higher than that for the loaded Empress-1 crowns. There was no significant difference between the PFM crown group and the Procera group. Within the limits of this pilot investigation, it seems that zirconia implants restored with the Procera crowns possibly fulfill the biomechanical requirements for anterior teeth. However, further investigations with larger sample sizes have to confirm these preliminary results. As three Empress-1 crowns showed crack development in the loading area of the steatite balls in the artificial mouth, their clinical use on zirconia implants has to be questioned.

  19. IPS Empress crown system: three-year clinical trial results.

    PubMed

    Sorensen, J A; Choi, C; Fanuscu, M I; Mito, W T

    1998-02-01

    The IPS Empress system is a highly esthetic hot pressed glass ceramic material for fabrication of single crowns. Adhesive cementation of the system not only contributes to the esthetics but is necessary for increased strength of the crown. The purpose of this prospective clinical trials was to evaluate the longevity of 75 adhesively cemented Empress full crowns. An additional aim was to assess the adhesive cementation methodology and potential side effects. At the three-year point, one molar crown fractured for a 1.3 percent failure rate. The resin cementation technique that was employed exhibited a low incidence of microleakage with few clinical side effects. There was a 5.6 percent incidence of post-cementation sensitivity, with all symptoms subsiding by eight weeks. None of the crowns in the study required endodontic therapy.

  20. Reduction-resistant and reduction-catalytic double-crown nickel nanoclusters

    NASA Astrophysics Data System (ADS)

    Zhu, Min; Zhou, Zhou, Shiming; Yao, Chuanhao; Liao, Lingwen; Wu, Zhikun

    2014-11-01

    In this work, an attempt to synthesize zero-valent Ni nanoclusters using the Brust method resulted in an unexpected material, Ni6(SCH2CH2Ph)12, which is a nanoscale Ni(ii)-phenylethanethiolate complex and a hexameric, double-crown-like structure, as determined by a series of characterizations, including mass spectrometry (MS), thermal gravimetric analysis (TGA), single-crystal X-ray diffraction (XRD), and X-ray photoelectron spectrometry (XPS). An interesting finding is that this complex is resistant to aqueous BH4-. Investigations into other metal-phenylethanethiolate and Ni-thiolate complexes reveal that this property is not universal and appears only in complexes with a double-crown-like structure, indicating the correlation between this interesting property and the complexes' special structure. Another interesting finding is that the reduction-resistant Ni6(SCH2CH2Ph)12 exhibits remarkably higher catalytic activity than a well-known catalyst, Au25(SCH2CH2Ph)18, toward the reduction of 4-nitrophenol at low temperature (e.g., 0 °C). This work will help stimulate more research on the properties and applications of less noble metal nanoclusters.In this work, an attempt to synthesize zero-valent Ni nanoclusters using the Brust method resulted in an unexpected material, Ni6(SCH2CH2Ph)12, which is a nanoscale Ni(ii)-phenylethanethiolate complex and a hexameric, double-crown-like structure, as determined by a series of characterizations, including mass spectrometry (MS), thermal gravimetric analysis (TGA), single-crystal X-ray diffraction (XRD), and X-ray photoelectron spectrometry (XPS). An interesting finding is that this complex is resistant to aqueous BH4-. Investigations into other metal-phenylethanethiolate and Ni-thiolate complexes reveal that this property is not universal and appears only in complexes with a double-crown-like structure, indicating the correlation between this interesting property and the complexes' special structure. Another interesting finding is that the reduction-resistant Ni6(SCH2CH2Ph)12 exhibits remarkably higher catalytic activity than a well-known catalyst, Au25(SCH2CH2Ph)18, toward the reduction of 4-nitrophenol at low temperature (e.g., 0 °C). This work will help stimulate more research on the properties and applications of less noble metal nanoclusters. Electronic supplementary information (ESI) available: Experimental section, detailed structural data, MS analyses of M-SCH2CH2Ph complexes, stability study of Ni6 and TGA analysis of Au25(SCH2CH2Ph)18. See DOI: 10.1039/c4nr04981k

  1. Tree crown mapping in managed woodlands (parklands) of semi-arid West Africa using WorldView-2 imagery and geographic object based image analysis.

    PubMed

    Karlson, Martin; Reese, Heather; Ostwald, Madelene

    2014-11-28

    Detailed information on tree cover structure is critical for research and monitoring programs targeting African woodlands, including agroforestry parklands. High spatial resolution satellite imagery represents a potentially effective alternative to field-based surveys, but requires the development of accurate methods to automate information extraction. This study presents a method for tree crown mapping based on Geographic Object Based Image Analysis (GEOBIA) that use spectral and geometric information to detect and delineate individual tree crowns and crown clusters. The method was implemented on a WorldView-2 image acquired over the parklands of Saponé, Burkina Faso, and rigorously evaluated against field reference data. The overall detection rate was 85.4% for individual tree crowns and crown clusters, with lower accuracies in areas with high tree density and dense understory vegetation. The overall delineation error (expressed as the difference between area of delineated object and crown area measured in the field) was 45.6% for individual tree crowns and 61.5% for crown clusters. Delineation accuracies were higher for medium (35-100 m(2)) and large (≥100 m(2)) trees compared to small (<35 m(2)) trees. The results indicate potential of GEOBIA and WorldView-2 imagery for tree crown mapping in parkland landscapes and similar woodland areas.

  2. Tree Crown Mapping in Managed Woodlands (Parklands) of Semi-Arid West Africa Using WorldView-2 Imagery and Geographic Object Based Image Analysis

    PubMed Central

    Karlson, Martin; Reese, Heather; Ostwald, Madelene

    2014-01-01

    Detailed information on tree cover structure is critical for research and monitoring programs targeting African woodlands, including agroforestry parklands. High spatial resolution satellite imagery represents a potentially effective alternative to field-based surveys, but requires the development of accurate methods to automate information extraction. This study presents a method for tree crown mapping based on Geographic Object Based Image Analysis (GEOBIA) that use spectral and geometric information to detect and delineate individual tree crowns and crown clusters. The method was implemented on a WorldView-2 image acquired over the parklands of Saponé, Burkina Faso, and rigorously evaluated against field reference data. The overall detection rate was 85.4% for individual tree crowns and crown clusters, with lower accuracies in areas with high tree density and dense understory vegetation. The overall delineation error (expressed as the difference between area of delineated object and crown area measured in the field) was 45.6% for individual tree crowns and 61.5% for crown clusters. Delineation accuracies were higher for medium (35–100 m2) and large (≥100 m2) trees compared to small (<35 m2) trees. The results indicate potential of GEOBIA and WorldView-2 imagery for tree crown mapping in parkland landscapes and similar woodland areas. PMID:25460815

  3. Influence of surface treatment and cyclic loading on the durability of repaired all-ceramic crowns

    PubMed Central

    ATTIA, Ahmed

    2010-01-01

    Objective This study investigated the durability of repaired all-ceramic crowns after cyclic loading. Material and methods Eighty In-ceram zirconia crowns were fabricated to restore prepared maxillary premolars. Resin cement was used for cementation of crowns. Palatal cusps were removed to simulate fracture of veneering porcelain and divided into 4 groups (n = 20). Fracture site was treated before repair as follows: roughening with diamond bur, (DB); air abrasion using 50 µm Al2O3, (AA) and silica coating using Cojet system followed by silane application, (SC). Control group (CG) 20 specimens were left without fracture. Palatal cusps were repaired using composite resin. Specimens were stored in water bath at 37°C for one week. Ten specimens of each group were subjected to cyclic loading. Fracture load (N) was recorded for each specimen using a universal testing machine. Two-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) test (α=.05) were used for statistical analysis. Results There was statistically significant difference between control and tested groups, (p<0.001). Post Hoc analysis with the Tukey HSD test showed that cyclic loading fatigue significantly decreased means fracture load of control and test groups as follows (CG, 950.4±62.6 / 872.3±87.4, P = 0.0004), (DB, 624.2 ±38 / 425.5± 31.7, P <.001), (AA, 711.5 ±15.5 / 490 ± 25.2, p <0.001) and (SC, 788.7 ± 18.1 / 610.2 ± 25.2, P <.001), while silica coating and silane application significantly increased fracture load of repaired crowns (p<0.05). Conclusion Repair of fractured Inceram zirconia crowns after chairside treatment of the fracture site by silica coating and silane application could improve longevity of repaired In-ceram zirconia crowns. PMID:20485932

  4. UrbanCrowns: an assessment and monitoring tool for urban trees

    Treesearch

    Matthew F. Winn; Philip A. Araman; Sang-Mook Lee

    2011-01-01

    UrbanCrowns is a Windows®-based computer program used to assess the crown characteristics of urban trees. The software analyzes side-view digital photographs of trees to compute several crown metrics, including crown height, crown diameter, live crown ratio, crown volume, crown density, and crown transparency. Potential uses of the UrbanCrowns program include...

  5. [Study on content of nickel in saliva released from the nickel-chromium and the nickel-chromium-titanium porcelain alloy].

    PubMed

    Wang, Wen-Jie; Zhang, Tai-Qiang; Wei, Hong

    2010-02-01

    The purpose of the study was to investigate the content of nickel (Ni) ion in patients' saliva after wearing the porcelain-fused-to nickel-chromium (Ni-Cr) crown or the porcelain-fused-to nickel-chromium-titanium(Ni-Cr-Ti) crown. 50 patients who had one molar or premolar needed repairing were selected and divided into two groups randomly. Patients in one group were fabricated with porcelain-fused-to Ni-Cr crown and the patients in the other group were fabricated with porcelain-fused-to Ni-Cr-Ti crown. Collect the patients' saliva before wearing, 1 week, 3 months, and 6 months after wearing. The content of Ni ion in saliva was detected by inductively coupled plasma mass spectrometry (ICP-MS). The content of Ni ion in both groups increased at the first week, and go back after 6 months. There were no significant differences before wearing, 1 week, 3 months, and 6 months after wearing. There were no significant differences between the two groups. Wearing the porcelain-fused-to Ni-Cr crown or the porcelain-fused-to Ni-Cr-Ti crown has no significant influence on the content of Ni ion in saliva.

  6. [Finite element analysis of the maxillary central incisor with traditional and modified crown lengthening surgery and post-core restoration in management of crown-root fracture].

    PubMed

    Zhen, M; Wei, Y P; Hu, W J; Rong, Q G; Zhang, H

    2016-06-01

    To construct three-dimensional finite element models with modified crown lengthening surgery and post-core restoration in management of various crown-root fracture types, to investigate the intensity and distribution of stressin models mentioned above, and to compare and analyze the indications of traditional and modified crown lengthening surgeries from the mechanic point of view. Nine three-dimensional finite element models with modified crown lengthening surgery and post-core restoration were established and analyzed by micro-CT scanning technique, dental impression scanner, Mimics 10.0, Geomagic studio 9.0 and ANSYS 14.0 software. The von Mises stress of dentin, periodontal ligament, alveolar bone, post and core, as well as the periodontal ligament area and threshold limit value were calculated and compared with the findings of traditional crown lengthening models which had been published earlierby our research group. The von Mises stress intensity of modified crown lengthening models were: dentin>post>core>alveolar bone>periodontal ligament. The maximum von Mises stress of dentin(44.37-80.58 MPa)distributed in lingual central shoulder. The periodontal ligament area of the modified crown lengthening surgery was reduced by 6% to 28%, under the same crown-root fracture conditions, the periodontal ligament area of modified crown lengthening models was larger than that of the traditional crown lengthening models. In modified crown lengthening surgery models, the von Mises stress of periodontal ligament of B3L1m, B3L2m, B3L3m models exceeded their limit values, however, the von Mises stress of periodontal ligament of the B2L2c, B2L3c, B3L1c, B3L2c, B3L3c models exceeded their limit values in traditional crown lengthening surgery models. The modified crown lengthening surgery conserves more periodontal supporting tissues, which facilitates the long-term survival of teeth. The indication of modified crown lengthening surgery is wider than traditional method. The maxillary central incisors with labial fracture at gingival margin level and with palatal fracture at or below the alveolar crest level are not the indication of the crown lengthening surgery.

  7. Longevity of metal-ceramic crowns cemented with self-adhesive resin cement: a prospective clinical study

    PubMed

    Brondani, Lucas Pradebon; Pereira-Cenci, Tatiana; Wandsher, Vinicius Felipe; Pereira, Gabriel Kalil; Valandro, Luis Felipe; Bergoli, César Dalmolin

    2017-04-10

    Resin cements are often used for single crown cementation due to their physical properties. Self-adhesive resin cements gained widespread due to their simplified technique compared to regular resin cement. However, there is lacking clinical evidence about the long-term behavior of this material. The aim of this prospective clinical trial was to assess the survival rates of metal-ceramic crowns cemented with self-adhesive resin cement up to six years. One hundred and twenty-nine subjects received 152 metal-ceramic crowns. The cementation procedures were standardized and performed by previously trained operators. The crowns were assessed as to primary outcome (debonding) and FDI criteria. Statistical analysis was performed using Kaplan-Meier statistics and descriptive analysis. Three failures occurred (debonding), resulting in a 97.6% survival rate. FDI criteria assessment resulted in scores 1 and 2 (acceptable clinical evaluation) for all surviving crowns. The use of self-adhesive resin cement is a feasible alternative for metal-ceramic crowns cementation, achieving high and adequate survival rates.

  8. Periodontal response to all-ceramic crowns (IPS Empress) in general practice.

    PubMed

    Al-Wahadni, A M; Mansour, Y; Khader, Y

    2006-02-01

    The purpose of this study was to investigate the periodontal response to the presence of all-ceramic crowns (IPS Empress) in general practice patients. The convenience sample included 82 IPS Empress crowns placed in 64 patients. These crowns had been in place for an average of 16.27 (SD 9.26) months and ranged from 6.2 to 48.87 months at the time of clinical examination. Periodontal health status (as determined by dental plaque, gingival health status, periodontal pockets) was assessed around all crowned teeth and around matched contralateral teeth by one calibrated examiner. Periodontal indices utilized included the Plaque Index (PI), Gingival Index (GI) and pocket depth (PD) with calibrated probes graduated in millimetres. Plaque, gingival and PD values for crowned teeth were compared with those for control teeth using Wilcoxon signed-rank test for each clinical parameters. Chi-square was used to test the significance of the difference in their distribution between crowns and control teeth. Statistically, PI (0.35), GI (0.41) and mean PD scores (1.42) of IPS Empress crowned teeth compared less favourably with scores of the control teeth (0.27, 0.23 and 0.86 respectively). Teeth with IPS Empress crowns had poorer periodontal health and more clinically evident plaque than uncrowned teeth.

  9. The effect of retentive groove, sandblasting and cement type on the retentive strength of stainless steel crowns in primary second molars--an in vitro comparative study.

    PubMed

    Veerabadhran, M M; Reddy, V; Nayak, U A; Rao, A P; Sundaram, M A

    2012-01-01

    This in vitro study was conducted to find out the effect of retentive groove, sand blasting and cement type on the retentive strength of stainless steel crowns in primary second molars. Thirty-two extracted intact human maxillary and mandibular primary second molars were embedded in aluminum blocks utilizing autopolymerising acrylic resin. After tooth preparation, the 3M stainless steel crown was adjusted to the prepared tooth. Then weldable buccal tubes were welded on the buccal and lingual surfaces of each crown as an attachment for the testing machine. A full factorial design matrix for four factors (retentive groove placement on the tooth, cement type, sandblasting and primary second molar) at two levels each was developed and the study was conducted as dictated by the matrix. The lower and upper limits for each factor were without and with retentive groove placement on the tooth, GIC and RMGIC, without and with sandblasting of crown, maxillary and mandibular second primary molar. For those teeth for which the design matrix dictated groove placement, the retentive groove was placed on the middle third of the buccal surface of the tooth horizontally and for those crowns for which sandblasting of the crowns are to be done, sandblasting was done with aluminium oxide with a particle size of 250 mm. The crowns were luted with either GIC or RMGIC, as dictated by the design matrix. Then the retentive strength of each sample was evaluated by means of an universal testing machine. The obtained data was analyzed using ANOVA for statistical analysis of the data and 't'- tests for pairwise comparison. The mean retentive strength in kg/cm 2 stainless steel crowns luted with RMGIC was 19.361 and the mean retentive strength of stainless steel crowns luted with GIC was 15.964 kg/cm 2 with a mean difference of 3.397 kg/cm 2 and was statistically significant. The mean retentive strength in kg/cm 2 of stainless steel crowns, which was not sandblasted, was 18.880 and which was sandblasted was 16.445 kg/cm 2 with a mean difference of 2.436 kg/cm 2 . These results were again statistically significant. It was found that the crowns luted with resin-modified glass ionomer cements (RMGIC's) offered better retentive strength of crowns than glass ionomer cements (GIC) and stainless steel crowns which were cemented without sandblasting showed higher mean retentive strength than with sandblasting of crowns. The presence of groove did not influence the retentive strength of stainless steel crowns.

  10. Vertebral formula in red-crowned crane (Grus japonensis) and hooded crane (Grus monacha).

    PubMed

    Hiraga, Takeo; Sakamoto, Haruka; Nishikawa, Sayaka; Muneuchi, Ippei; Ueda, Hiromi; Inoue, Masako; Shimura, Ryoji; Uebayashi, Akiko; Yasuda, Nobuhiro; Momose, Kunikazu; Masatomi, Hiroyuki; Teraoka, Hiroki

    2014-04-01

    Red-crowned cranes (Grus japonensis) are distributed separately in the east Eurasian Continent (continental population) and in Hokkaido, Japan (island population). The island population is sedentary in eastern Hokkaido and has increased from a very small number of cranes to over 1,300, thus giving rise to the problem of poor genetic diversity. While, Hooded cranes (Grus monacha), which migrate from the east Eurasian Continent and winter mainly in Izumi, Kagoshima Prefecture, Japan, are about eight-time larger than the island population of Red-crowned cranes. We collected whole bodies of these two species, found dead or moribund in eastern Hokkaido and in Izumi, and observed skeletons with focus on vertebral formula. Numbers of cervical vertebrae (Cs), thoracic vertebrae (Ts), vertebrae composing the synsacrum (Sa) and free coccygeal vertebrae (free Cos) in 22 Red-crowned cranes were 17 or 18, 9-11, 13 or 14 and 7 or 8, respectively. Total number of vertebrae was 47, 48 or 49, and the vertebral formula was divided into three types including 9 sub-types. Numbers of Cs, Ts, vertebrae composing the Sa and free Cos in 25 Hooded cranes were 17 or 18, 9 or 10, 12-14 and 6-8, respectively. Total number of vertebrae was 46, 47, 48 or 49, and the vertebral formula was divided into four types including 14 sub-types. Our findings clearly showed various numerical vertebral patterns in both crane species; however, these variations in the vertebral formula may be unrelated to the genetic diversity.

  11. The effect of multicolored machinable ceramics on the esthetics of all-ceramic crowns.

    PubMed

    Reich, Sven; Hornberger, Helga

    2002-07-01

    Computer-aided design/computer-assisted machining systems offer the possibility of fabricating restorations from one machinable ceramic block. Whether multishaded blocks improve esthetic results and are a viable alternative to individually stained ceramics has not been fully determined. The aim of this investigation was to examine the effect of multishaded blocks on the esthetic appearance of all-ceramic CEREC crowns and compare these crowns with single-shade and stained restorations. Ten subjects were included in this study. For each subject, 6 different crowns were milled with the use of a CEREC machine. One crown was milled from each of the following machinable ceramic materials: CEREC Vitablocs Mark II in classic colors; Vitablocs Mark II in 3D-Master colors; Vitablocs Mark II in either classic or 3D-Master colors, with additional staining; Megadenta Bloxx multishaded; Mark II experimental multilayer; and an experimental multilayer leucite ceramic. Three independent examiners assessed the esthetic appearance of crowns fabricated to match each subject's anterior tooth shade. A scale of 1 to 6 was used to score the shade match and esthetic adaptation of each crown, with 1 representing excellent characteristics and 3.5 serving as the threshold for clinical acceptability. The examiners' scores were averaged, and the mean values were analyzed with the Wilcoxon signed rank test (P

  12. Failure probability of three designs of zirconia crowns

    PubMed Central

    Ramos, G. Freitas; Monteiro, E. Barbosa Carmona; Bottino, M.A.; Zhang, Y.; de Melo, R. Marques

    2015-01-01

    Objectives This study utilized a 2-parameter Weibull analysis for evaluation of lifetime of fully or partially porcelain-/glaze-veneered zirconia crowns after fatigue test. Methods Sixty first molars were selected and prepared for full-coverage crowns with three different designs(n = 20): Traditional –crowns with zirconia framework covered with feldspathic porcelain; Modified– crowns partially covered with veneering porcelain; and Monolithic–full-contour zirconia crowns. All specimens were treated with a glaze layer. Specimens were subjected to mechanical cycling (100N, 3Hz) with a piston with hemispherical tip (Ø=6 mm) until the specimens failed or up to 2×106 cycles. Every 500,000 cycles intervals, the fatigue tests were interrupted, and stereomicroscopy (10 X) was used to inspect the specimens for damage. We performed Weibull analysis of interval data to calculate the number of failures in each interval. Results The types and number of failures according to the groups were: cracking (Traditional-13, Modified-6) and chipping (Traditional-4) of the feldspathic porcelain, followed by delamination (Traditional-1) at the veneer/core interface and debonding (Monollithic-2) at the cementation interface. Weibull parameters (beta, scale; and eta, shape), with a two-sided confidence interval of 95%, were: Traditional – 1.25 and 0.9 × 106cycles; Modified– 0.58 and 11.7 × 106 cycles; and Monolithic – 1.05 and 16.5 × 106 cycles. Traditional crowns showed greater susceptibility to fatigue, the Modified group presented higher propensity to early failures, and the Monolithic group showed no susceptibility to fatigue. The Modified and Monolithic groups presented the highest number of crowns with no failures after the fatigue test. Conclusions The three crown designs presented significantly different behaviors under fatigue. The Modified and the Monolithic groups presented less probability to failure after 2×106cycles. PMID:26509988

  13. Developmental toxicity of diphenyl ether herbicides in nestling American kestrels.

    PubMed

    Hoffman, D J; Spann, J W; LeCaptain, L J; Bunck, C M; Rattner, B A

    1991-11-01

    Beginning the day after hatching, American kestrel (Falco sparverius) nestlings were orally dosed for 10 consecutive days with 5 microliters/g of corn oil (controls) or one of the diphenyl ether herbicides (nitrofen, bifenox, or oxyfluorfen) at concentrations of 10, 50, 250, or 500 mg/kg in corn oil. At 500 mg/kg, nitrofen resulted in complete nestling mortality, bifenox in high (66%) mortality, and oxyfluorfen in no mortality. Nitrofen at 250 mg/kg reduced nestling growth as reflected by decreased body weight, crown-rump length, and bone lengths including humerus, radius-ulna, femur, and tibiotarsus. Bifenox at 250 mg/kg had less effect on growth than nitrofen, but crown-rump, humerus, radius-ulna, and femur were significantly shorter than controls. Liver weight as a percent of body weight increased with 50 and 250 mg/kg nitrofen. Other manifestations of impending hepatotoxicity following nitrofen ingestion included increased hepatic GSH peroxidase activity in all nitrofen-treated groups, and increased plasma enzyme activities for ALT, AST, and LDH-L in the 250-mg/kg group. Bifenox ingestion resulted in increased hepatic GSH peroxidase activity in the 50- and 250-mg/kg groups. Nitrofen exposure also resulted in an increase in total plasma thyroxine (T4) concentration. These findings suggest that altricial nestlings are more sensitive to diphenyl ether herbicides than young or adult birds of precocial species.

  14. Isomorphism Within the Hexagonal Columnar Mesophase of Molecular and Macromolecular Self- and Co-Assembled Columns Containing Tapered Groups

    DTIC Science & Technology

    1994-06-30

    benzyloxylbenzoic acid , their corresponding polymethacrylates , and of 4’- methyl (benzo- 15-crown-5)-3,4,5-tris[4-(n-dodecan- 1 -yloxy)benzyloxylbenzoate within...l-yloxy)benzyloxy]benzoic acid , of their corresponding polymethacrylates , and of 4’-methyl(benzo- 15-crown-5)-3,4,5-tris[4- (n-dodecan- 1-yloxy...benzyloxylbenzoic acid , of their corresponding polymethacrylates ,18a and of 4’-methyl(benzo-15-crown-5)-3,4,5-tris[4-(n-dodecan-l- yloxy)benzyloxy]benzoate 1 7

  15. Process for extracting technetium from alkaline solutions

    DOEpatents

    Moyer, Bruce A.; Sachleben, Richard A.; Bonnesen, Peter V.

    1995-01-01

    A process for extracting technetium values from an aqueous alkaline solution containing at least one alkali metal hydroxide and at least one alkali metal nitrate, the at least one alkali metal nitrate having a concentration of from about 0.1 to 6 molar. The solution is contacted with a solvent consisting of a crown ether in a diluent for a period of time sufficient to selectively extract the technetium values from the aqueous alkaline solution. The solvent containing the technetium values is separated from the aqueous alkaline solution and the technetium values are stripped from the solvent.

  16. [Effect of the vacuum-formed retainer on preventing the proximal contact loss between implant supported crown and adjacent natural teeth].

    PubMed

    Zeng, B J; Guo, Y; Yu, R Y

    2018-06-18

    To evaluate the effect of the vacuum-formed retainer on preventing the proximal contact loss between the implant supported crown and its adjacent natural teeth. Forty-six posterior implant crowns in the mandible including 92 interproximal contacts in 46 patients (19 men, 27 women) aged from 25 to 66 years were included. The participants in experimental group (22 cases) were vacuum-formed retainers at night, while participants in control group (24 cases) only received routine examination. The two groups were not different in age, gender, the time interval of the tooth loss and tooth position at baseline. Mesial and distal proximal contact tightness was measured using the orthodontic dynamometer and metallic articulating film immediately after crown delivery, and 1-month, 3-month, 6-month, and 1-year follow-up respectively. The articulating film was inserted interdentally from the occlusal direction, and then it was slowly removed in the buccallingual direction by the dynamometer. Increasing the number of films (N) piece by piece until the frictional force (F) was great than 0, and the number of films (N) was recorded. At each follow-up, proximal contact between implant crown and its adjacent teeth was considered to be loss if the number of films (N) used at immediate crown delivery passed without frictional force (F=0). Besides, the periodontal conditions [scored according to the probing depth (PD), bleeding index (BI), mobility (M)] and complaint of food impaction were recorded. The mesial and distal proximal contact loss rates were compared between the two groups at different times. Chi-square test or Fisher's exact test was used for statistical analysis. The proximal contact loss rate on the mesial surface of the implant supported crown continuously increased over the follow-up periods. At the end of the 1-, 3-, and 6-month follow ups, 18.2%, 22.7% and 27.3% were identified for the contact loss rates on the mesial surface of the implant supported crown in the experimental group, respectively. Meanwhile in control group, the rates were 20.8%, 37.5% and 45.8%. No significant differences were observed at the end of the 1-, 3-, and 6-month follow ups(1-month: χ 2 =0.000, P=1.000; 3-month: χ 2 =1.183, P=0.277; 6-month: χ 2 =1.697, P=0.193). The proximal contact loss rate on the mesial surface in control group (62.5%) was significantly higher than that in the experimental group (31.8%, χ 2 =4.330, P=0.037) at the end of the 1-year follow-up. However, no statistical difference was found on the distal surfaces between the two groups during the whole follow-up periods. The first open contact was noted 1 month after crown insertion. By wearing vacuum-formed retainer for one year, the incidence of open contacts between the posterior implant prostheses and mesial adjacent teeth in the mandible has been reduced.

  17. The influence of different cementation modes on the fracture resistance of feldspathic ceramic crowns.

    PubMed

    Groten, M; Pröbster, L

    1997-01-01

    One hundred twenty pressed feldspathic ceramic crowns were luted to 20 steel dies using six different cementation modes. Fracture resistance was tested under an angle of 45 degrees and was determined as the maximal fracture load. Crowns were tested with luting agent only (groups A and C) and after etching with hydrofluoric acid, silanating, and the application of a bonding agent (groups B, D, E, and F). The resulting means were: phosphate cement 294.3 (A) and 282.2 (B); glass-ionomer cement 217.2 (C) and 255.4 (D); resin composite 382.2 (E) and 687.6 (F). Statistical analysis revealed significantly greater fracture resistance (P < .01) of resin luted crowns. Bonding to the die almost doubled the fracture resistance. Conditioning of the inner surfaces of the crowns did not improve the fracture resistance of crowns luted using zinc phosphate or glass-ionomer cements.

  18. Experimental investigation of the abrasive crown dynamics in orbital atherectomy.

    PubMed

    Zheng, Yihao; Belmont, Barry; Shih, Albert J

    2016-07-01

    Orbital atherectomy is a catheter-based minimally invasive procedure to modify the plaque within atherosclerotic arteries using a diamond abrasive crown. This study was designed to investigate the crown motion and its corresponding contact force with the vessel. To this end, a transparent arterial tissue-mimicking phantom made of polyvinyl chloride was developed, a high-speed camera and image processing technique were utilized to visualize and quantitatively analyze the crown motion in the vessel phantom, and a piezoelectric dynamometer measured the forces on the phantom during the procedure. Observed under typical orbital atherectomy rotational speeds of 60,000, 90,000, and 120,000rpm in a 4.8mm caliber vessel phantom, the crown motion was a combination of high-frequency rotation at 1000, 1500, and 1660.4-1866.1Hz and low-frequency orbiting at 18, 38, and 40Hz, respectively. The measured forces were also composed of these high and low frequencies, matching well with the rotation of the eccentric crown and the associated orbital motion. The average peak force ranged from 0.1 to 0.4N at different rotational speeds. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Fracture load of ceramic restorations after fatigue loading.

    PubMed

    Baladhandayutham, Balasudha; Lawson, Nathaniel C; Burgess, John O

    2015-08-01

    A clinician must decide what ceramic coping and veneer material to prescribe based on the amount of tooth reduction possible and the desired esthetic outcome of the restoration. The purpose of this in vitro study was to compare the fracture strength of monolithic and bilayered lithium disilicate (IPS e.max) and zirconia (LAVA) crowns at clinically relevant thicknesses after load cycling. Crowns (n=8) were fabricated from 6 groups: 1.2-mm monolithic lithium disilicate, 1.5-mm monolithic lithium disilicate, 1.5-mm bilayered lithium disilicate with hand-layered veneer, 0.6 mm monolithic zirconia, 1.2-mm bilayered zirconia with hand-layered veneer, and 1.2-mm bilayered zirconia with milled veneer (dimension represents thickness at the occlusal pit). Crowns were cemented to identical milled resin dies with resin-modified glass ionomer cement. Cemented crowns were stored at 37°C for 24 hours and load cycled for 200,000 cycles at 25 N at a rate of 40 cycles/minute. The ultimate fracture load for each specimen was measured in a universal testing machine. Data were analyzed with a 1-way ANOVA and Tukey honest significant difference post hoc analysis (α=.05). Mean ±SD fracture load values were 1465 ±330 N for monolithic lithium disilicate (1.2-mm thickness) and 2027 ±365 N (1.5-mm thickness) and 1732 ±315 N for bilayered hand-veneered lithium disilicate (1.5-mm thickness). Fracture loads were 1669 ±311 N for monolithic zirconia crowns (0.6mm thickness), 2625 ±300 N for zirconia milled-veneered (1.2-mm thickness), and 2655 ±590N for zirconia hand-veneered crowns (1.2mm thickness). One-way ANOVA showed a statistically significant difference among the groups (P<.01). Veneered zirconia crowns showed the highest fracture strength, 1.2-mm hand veneered zirconia was similar to that of 1.5-mm monolithic zirconia, and all other groups were not statistically different. Crowns of 1.2-mm bilayered zirconia had higher fracture loads than 0.6-mm zirconia or 1.2-mm lithium disilicate monolithic crowns. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Improvement of rolling 6 mm thin plates in plate rolling mill PT. Krakatau Posco

    NASA Astrophysics Data System (ADS)

    Pujiyanto, Hamdani

    2017-01-01

    A 6-mm thin plate is difficult to produce especially if the product requires wide size and high strength. Flatness is the main quality issue in rolling 6-mm plate using a 4-high reversing mill which use ±1100-mm work roll. Thus some methods are applied to overcome such issue in order to comply to customer quality requirement. Pre-rolling, rolling, and post-rolling conditions have to be considered comprehensively. Roll unit management will be the key factor before rolling condition. The roll unit itself has a significant impact on work roll crown wearness in relation with work roll intial crown and thermal crown. Work roll crown along with the modification of hydraulic gap control (HGC) could directly alter the flatness of the plate.

  1. Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology.

    PubMed

    Huang, Zhuoli; Zhang, Lu; Zhu, Jingwei; Zhang, Xiuyin

    2015-06-01

    Selective laser melting (SLM) technology has been introduced to fabricate dental restorations. However, the fit of these restorations still needs further study. The purpose of this in vivo investigation was to compare the marginal and internal fit of SLM metal ceramic crowns with 2 lost-wax cast metal ceramic crowns and to evaluate the influence of tooth type on the marginal and internal fit of these crowns. A total of 330 metal ceramic crowns were evaluated. The metal copings were fabricated with SLM Co-Cr, cast Au-Pt, and cast Co-Cr alloy (n=110). The marginal and internal gaps of crowns were recorded by using a replica technique. The anterior and premolar replicas were sectioned 2 times, and molar replicas were sectioned 4 times. The marginal and internal gap width of each cross section was examined by stereomicroscope at ×30 magnification. Two-way analysis of variance was performed to identify the statistical difference among the groups. The marginal fit of the SLM Co-Cr group (75.6 ±32.6 μm) was not different from the cast Au-Pt group (76.8 ±32.1 μm) (P>.05) but was better than the cast Co-Cr group (91.0 ±36.3 μm) (P<.01). No significant difference was found among the SLM Co-Cr group (127.3 ±45.8 μm), cast Au-Pt group (129.9 ±61.1 μm). and cast Co-Cr group (142.5 ±63.7 μm) (P>.05). The mean occlusal gap width of the SLM Co-Cr group (309.8 ±106.6 μm) was significantly higher than that of the cast Au-Pt group (254.6 ±109.6 μm) and the cast Co-Cr group (249.6 ±110.4 μm) (P<.005). No significant difference was found in the marginal fit among the anterior group (84.4 ±35.1 μm), the premolar group (80.6 ±26.3 μm), and the molar group (82.7 ±38.0 μm) (P>.05). Also, no significant difference was found in the axial fit among the anterior group (138.3 ±52.5 μm), the premolar group (132.9 ±50.4 μm), and the molar group (134.4 ±52.5 μm) (P>.05). The anterior group (267.6 ±110.2 μm) did not differ from the premolar group (270.2 ±112.8 μm) and the molar group (268.6 ±110.5 μm) in occlusal fit (P>.05). The marginal fit of SLM Co-Cr metal ceramic crowns was similar to that of the cast Au-Pt metal ceramic crowns and was better than that of the cast Co-Cr metal ceramic crowns. The SLM Co-Cr metal ceramic crowns were not significantly different from the 2 cast metal ceramic crowns in axial fit but were less accurate in occlusal fit. Tooth type did not influence the marginal and internal fit of the metal ceramic crowns. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Time-dependent fracture probability of bilayer, lithium-disilicate-based, glass-ceramic, molar crowns as a function of core/veneer thickness ratio and load orientation.

    PubMed

    Anusavice, Kenneth J; Jadaan, Osama M; Esquivel-Upshaw, Josephine F

    2013-11-01

    Recent reports on bilayer ceramic crown prostheses suggest that fractures of the veneering ceramic represent the most common reason for prosthesis failure. The aims of this study were to test the hypotheses that: (1) an increase in core ceramic/veneer ceramic thickness ratio for a crown thickness of 1.6mm reduces the time-dependent fracture probability (Pf) of bilayer crowns with a lithium-disilicate-based glass-ceramic core, and (2) oblique loading, within the central fossa, increases Pf for 1.6-mm-thick crowns compared with vertical loading. Time-dependent fracture probabilities were calculated for 1.6-mm-thick, veneered lithium-disilicate-based glass-ceramic molar crowns as a function of core/veneer thickness ratio and load orientation in the central fossa area. Time-dependent fracture probability analyses were computed by CARES/Life software and finite element analysis, using dynamic fatigue strength data for monolithic discs of a lithium-disilicate glass-ceramic core (Empress 2), and ceramic veneer (Empress 2 Veneer Ceramic). Predicted fracture probabilities (Pf) for centrally loaded 1.6-mm-thick bilayer crowns over periods of 1, 5, and 10 years are 1.2%, 2.7%, and 3.5%, respectively, for a core/veneer thickness ratio of 1.0 (0.8mm/0.8mm), and 2.5%, 5.1%, and 7.0%, respectively, for a core/veneer thickness ratio of 0.33 (0.4mm/1.2mm). CARES/Life results support the proposed crown design and load orientation hypotheses. The application of dynamic fatigue data, finite element stress analysis, and CARES/Life analysis represent an optimal approach to optimize fixed dental prosthesis designs produced from dental ceramics and to predict time-dependent fracture probabilities of ceramic-based fixed dental prostheses that can minimize the risk for clinical failures. Copyright © 2013 Academy of Dental Materials. All rights reserved.

  3. Time-dependent fracture probability of bilayer, lithium-disilicate-based glass-ceramic molar crowns as a function of core/veneer thickness ratio and load orientation

    PubMed Central

    Anusavice, Kenneth J.; Jadaan, Osama M.; Esquivel–Upshaw, Josephine

    2013-01-01

    Recent reports on bilayer ceramic crown prostheses suggest that fractures of the veneering ceramic represent the most common reason for prosthesis failure. Objective The aims of this study were to test the hypotheses that: (1) an increase in core ceramic/veneer ceramic thickness ratio for a crown thickness of 1.6 mm reduces the time-dependent fracture probability (Pf) of bilayer crowns with a lithium-disilicate-based glass-ceramic core, and (2) oblique loading, within the central fossa, increases Pf for 1.6-mm-thick crowns compared with vertical loading. Materials and methods Time-dependent fracture probabilities were calculated for 1.6-mm-thick, veneered lithium-disilicate-based glass-ceramic molar crowns as a function of core/veneer thickness ratio and load orientation in the central fossa area. Time-dependent fracture probability analyses were computed by CARES/Life software and finite element analysis, using dynamic fatigue strength data for monolithic discs of a lithium-disilicate glass-ceramic core (Empress 2), and ceramic veneer (Empress 2 Veneer Ceramic). Results Predicted fracture probabilities (Pf) for centrally-loaded 1,6-mm-thick bilayer crowns over periods of 1, 5, and 10 years are 1.2%, 2.7%, and 3.5%, respectively, for a core/veneer thickness ratio of 1.0 (0.8 mm/0.8 mm), and 2.5%, 5.1%, and 7.0%, respectively, for a core/veneer thickness ratio of 0.33 (0.4 mm/1.2 mm). Conclusion CARES/Life results support the proposed crown design and load orientation hypotheses. Significance The application of dynamic fatigue data, finite element stress analysis, and CARES/Life analysis represent an optimal approach to optimize fixed dental prosthesis designs produced from dental ceramics and to predict time-dependent fracture probabilities of ceramic-based fixed dental prostheses that can minimize the risk for clinical failures. PMID:24060349

  4. High-energy metal air batteries

    DOEpatents

    Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

    2014-07-01

    Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

  5. High-energy metal air batteries

    DOEpatents

    Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

    2013-07-09

    Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

  6. Bulk Kosterlitz-Thouless Type Molecular Superconductor β″-(BEDT-TTF)2[(H2O)(NH4)2Cr(C2O4)3]·18-crown-6.

    PubMed

    Martin, Lee; Lopez, Jordan R; Akutsu, Hiroki; Nakazawa, Yasuhiro; Imajo, Shusaku

    2017-11-20

    A new molecular superconductor, β″-(BEDT-TTF) 2 [(H 2 O)(NH 4 ) 2 Cr(C 2 O 4 ) 3 ]·18-crown-6, has been synthesized from the organic donor molecule BEDT-TTF with the anion Cr(C 2 O 4 ) 3 3- . The crystal structure consists of conducting organic layers of BEDT-TTF molecules which adopt the β″ packing motif (layer A), layers of NH 4 + and Λ-Cr(C 2 O 4 ) 3 3- (layer B), layers of (H 2 O)(NH 4 )18-crown-6 (layer C), and layers of NH 4 + and Δ-Cr(C 2 O 4 ) 3 3- (layer D) which produce a superstructure with a repeating pattern of ABCDABCDA. As a result of this packing arrangement, this is the 2D superconductor with the widest gap between conducting layers where only a single donor packing motif is present (β″). Superconducting critical temperatures at ambient pressure observed by electrical transport and magnetic measurements are 4.0-4.9 and 2.5 K, respectively. The strong 2D nature of this system, the broad transition to T zero at 1.8K, and the transition of α of V ∝ I α from 1 to 3 on I-V curves strongly suggest that the superconducting transition is very close to a Kosterlitz-Thouless transition. The magnetic field dependence of the superconducting critical temperature parallel to the conducting plane gives an upper critical field μ 0 H c2∥ > 8 T, which is over the calculated Pauli-Clogston limit for this material.

  7. Effects of 12-crown-4 ether on the electrochemical performance of CoO2 and TiS2 cathodes in Li polymer electrolyte cells

    NASA Technical Reports Server (NTRS)

    Nagasubramanian, G.; Attia, Alan I.; Halpert, G.

    1992-01-01

    The effect of adding 12-crown-4 ether (12Cr4) to the polyethylene oxide (PEO) electrolyte on the electrochemical properties of cells with Li(x)CoO2 or TiS2 as the cathode was investigated. The polymer electrolyte films were: (1) PEO, LiBF4; (2) PEO, LiBF4 with 12Cr4; (3) Li(x)CoO2, PEO, and LiBF4; and (4) Li(x)CoO2, PEO, LiBF4, and 12Cr4. It was found that, although 12Cr4 improved the cell performance over cells without 12Cr4 in the shallow c/d cycles (cyclic voltammetric behavior), it did not seem to prolong the active life of the cell. The cells with CoO2 as the cathode failed after a few c/d cycles, while similar cells with TiS2 did not fail even after 12 c/d cycles. The probable cause of failure in the case of CoO2 is ascribed to the instability of the CoO2 cathode.

  8. Crown characteristics of juvenile loblolly pine 6 years after application of thinning and fertilization

    Treesearch

    Shufang Yu; Jim L. Chambers; Zhenmin Tang; James P. Barnett

    2003-01-01

    Total foliage dry mass and leaf area at the canopy hierarchical level of needle, shoot, branch and crown were measured in 48 trees harvested from a 14-year-old loblolly pine (Pinus taeda L.) plantation, six growing seasons after thinning and fertilization treatments. In the unthinned treatment, upper crown needles were heavier and had more leaf area...

  9. Optical effects of different colors of artificial gingiva on ceramic crowns.

    PubMed

    Wang, Jian; Lin, Jin; Gil, Mindy; Da Silva, John D; Wright, Robert; Ishikawa-Nagai, Shigemi

    2013-08-01

    The interaction between gingival color and the shade of ceramic restorations has never been fully studied. The purpose of this study is to investigate the optical effects of altering artificial gingival color on the ceramic crown shade in the cervical area. Thirty-one all-ceramic crowns of different shades were used in this study with six different artificial gingival colors. Using a spectrophotometer (Crystaleye(®) Olympus, Japan), we measured the shade of crowns in cervical areas with each of six different artificial gingiva. The crown color measured in the presence of pink artificial gingiva (control) was compared with the crown color with five other artificial gingiva. color difference values ΔE* were calculated and compared between the control group and test groups and the correlation of the artificial gingival color with the crown color was also assessed. Significant differences were found in the mean L* and a* values of all-ceramic crowns at the cervical regions in all six gingival color groups (p<0.001) and significant Pearson correlations were also found for the mean L* (r=0.987, p<0.001) and a* (r=0.856, p=0.03) values between the artificial gingiva and the ceramic crowns. The mean ΔE* values between the control group and each of the five other gingival groups were all significantly larger than the clinical perceptual threshold of ΔE* 1.6 (p<0.001). Different colors of artificial gingiva generated clinically detectable shade differences in the cervical region of ceramic crowns. Copyright © 2013. Published by Elsevier Ltd.

  10. Effect of the crown design and interface lute parameters on the stress-state of a machined crown-tooth system: a finite element analysis.

    PubMed

    Shahrbaf, Shirin; vanNoort, Richard; Mirzakouchaki, Behnam; Ghassemieh, Elaheh; Martin, Nicolas

    2013-08-01

    The effect of preparation design and the physical properties of the interface lute on the restored machined ceramic crown-tooth complex are poorly understood. The aim of this work was to determine, by means of three-dimensional finite element analysis (3D FEA) the effect of the tooth preparation design and the elastic modulus of the cement on the stress state of the cemented machined ceramic crown-tooth complex. The three-dimensional structure of human premolar teeth, restored with adhesively cemented machined ceramic crowns, was digitized with a micro-CT scanner. An accurate, high resolution, digital replica model of a restored tooth was created. Two preparation designs, with different occlusal morphologies, were modeled with cements of 3 different elastic moduli. Interactive medical image processing software (mimics and professional CAD modeling software) was used to create sophisticated digital models that included the supporting structures; periodontal ligament and alveolar bone. The generated models were imported into an FEA software program (hypermesh version 10.0, Altair Engineering Inc.) with all degrees of freedom constrained at the outer surface of the supporting cortical bone of the crown-tooth complex. Five different elastic moduli values were given to the adhesive cement interface 1.8GPa, 4GPa, 8GPa, 18.3GPa and 40GPa; the four lower values are representative of currently used cementing lutes and 40GPa is set as an extreme high value. The stress distribution under simulated applied loads was determined. The preparation design demonstrated an effect on the stress state of the restored tooth system. The cement elastic modulus affected the stress state in the cement and dentin structures but not in the crown, the pulp, the periodontal ligament or the cancellous and cortical bone. The results of this study suggest that both the choice of the preparation design and the cement elastic modulus can affect the stress state within the restored crown-tooth complex. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  11. 6. BRIDGE LOOKING SOUTH FROM CROWN POINT STATE PARK SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. BRIDGE LOOKING SOUTH FROM CROWN POINT STATE PARK SHOWING SURROUNDING DEVELOPMENT FROM CONSTRUCTION OF DAM - Columbia River Bridge at Grand Coulee Dam, Spanning Columbia River at State Route 155, Coulee Dam, Okanogan County, WA

  12. [The ultrastructure and activities of free radical scavenger in discolored gingiva adjacent to porcelain fused to metal crowns].

    PubMed

    Zhang, Zhong-ti; Yan, Lu; Zhong, Ming; Yang, Xiao-dong; Ai, Hong-jun

    2007-04-01

    This study was designed to study the discolored gingiva adjacent to porcelain fused to metal (PFM) crowns in terms of ultrastructure , SOD and GSH activities in 40 cases. The discolored gingival ultrastructures were observed and metal X-ray energy level was analyzed;The activities of SOD and GSH were measured and compared with normal control by student's t test and one-way ANOVA with SPSS10.0 software package. The discolored gingival ultrastructure had changes compared with the normal gingiva. Nickel and chromium were not found in the particles through X-ray energy machine within the discolored gingiva adjacent to PFM crown. The activities of SOD and GSH in discolored gingiva were significantly different from control(P<0.05) and the values at 6 to 18 months were significantly different from those at other times. The ultrastructure underwent changes in discolored gingiva after PFM restoration; the activity of SOD and GSH in discolored gingiva changed to result in apoptosis, and discoloration.

  13. Binding selectivity of dibenzo-18-crown-6 for alkali metal cations in aqueous solution: A density functional theory study using a continuum solvation model.

    PubMed

    Choi, Chang Min; Heo, Jiyoung; Kim, Nam Joon

    2012-08-08

    Dibenzo-18-crown-6 (DB18C6) exhibits the binding selectivity for alkali metal cations in solution phase. In this study, we investigate the main forces that determine the binding selectivity of DB18C6 for the metal cations in aqueous solution using the density functional theory (DFT) and the conductor-like polarizable continuum model (CPCM). The bond dissociation free energies (BDFE) of DB18C6 complexes with alkali metal cations (M+-DB18C6, M = Li, Na, K, Rb, and Cs) in aqueous solution are calculated at the B3LYP/6-311++G(d,p)//B3LYP/6-31 + G(d) level using the CPCM. It is found that the theoretical BDFE is the largest for K+-DB18C6 and decreases as the size of the metal cation gets larger or smaller than that of K+, which agrees well with previous experimental results. The solvation energy of M+-DB18C6 in aqueous solution plays a key role in determining the binding selectivity of DB18C6. In particular, the non-electrostatic dispersion interaction between the solute and solvent, which depends strongly on the complex structure, is largely responsible for the different solvation energies of M+-DB18C6. This study shows that the implicit solvation model like the CPCM works reasonably well in predicting the binding selectivity of DB18C6 in aqueous solution.

  14. Extraction of cesium, strontium and the platinium group metals from acidic high activity nuclear waste using a Purex process compatible organic extractant. Final report, December 15, 1980-August 15, 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, M.W. Jr.; Van Brunt, V.

    1984-09-14

    Purex process compatible organic systems which selectively and reversibly extract cesium, strontium, and palladium from synthetic mixed fission product solutions containing 3M HNO/sub 3/ have been developed. This advance makes the development of continuous solvent extraction processes for their recovery more likely. The most favorable cesium and strontium complexing solutions have been tested for radiation stability to 10/sup 7/ rad using a 0.4 x 10/sup 7/ rad/h /sup 60/Co source. The distribution coefficients dropped somewhat but remained above unity. For cesium the complexing organic solution is 5 vol % (0.1M) NNS, 27 vol % TBP and 68 vol % kerosenemore » containing 0.05m Bis 4,4',(5')(1-hydroxy 2-ethylhexyl)-benzo 18-crown-6 (Crown XVII). The NNS is a sulfonic acid cation exchanger. With an aqueous phase containing 0.006M Cs/sup +1/ in contact with an equal volume of extractant the D org/aq = 1.6 at a temperature of 25 to 35/sup 0/C. For strontium the complexing organic solution is 5 vol % (0.1M) NNS, 27 vol % TBP and 68 vol % Kerosene containing 0.02M Bis 4,4'(5') (1-hydroxyheptyl)cyclohexo 18-crown-6 (Crown XVI). With an aqueous phase containing 0.003M Sr/sup +2/ in contact with an equal volume of extractant the D org/aq = 1.98 at a temperature of 25 to 35/sup 0/C. For palladium the complexing organic solution consisted of a ratio of TBP/kerosene of 0.667 containing 0.3M Alamine 336 which is a tertiary amine anion exchanger. With an aqueous phase containing 0.0045M Pd/sup +/ in contact with an equal volume of extractant the D org/aq = 1.95 at a temperature of 25 to 35/sup 0/C.« less

  15. Designing molecular complexes using free-energy derivatives from liquid-state integral equation theory

    NASA Astrophysics Data System (ADS)

    Mrugalla, Florian; Kast, Stefan M.

    2016-09-01

    Complex formation between molecules in solution is the key process by which molecular interactions are translated into functional systems. These processes are governed by the binding or free energy of association which depends on both direct molecular interactions and the solvation contribution. A design goal frequently addressed in pharmaceutical sciences is the optimization of chemical properties of the complex partners in the sense of minimizing their binding free energy with respect to a change in chemical structure. Here, we demonstrate that liquid-state theory in the form of the solute-solute equation of the reference interaction site model provides all necessary information for such a task with high efficiency. In particular, computing derivatives of the potential of mean force (PMF), which defines the free-energy surface of complex formation, with respect to potential parameters can be viewed as a means to define a direction in chemical space toward better binders. We illustrate the methodology in the benchmark case of alkali ion binding to the crown ether 18-crown-6 in aqueous solution. In order to examine the validity of the underlying solute-solute theory, we first compare PMFs computed by different approaches, including explicit free-energy molecular dynamics simulations as a reference. Predictions of an optimally binding ion radius based on free-energy derivatives are then shown to yield consistent results for different ion parameter sets and to compare well with earlier, orders-of-magnitude more costly explicit simulation results. This proof-of-principle study, therefore, demonstrates the potential of liquid-state theory for molecular design problems.

  16. Designing molecular complexes using free-energy derivatives from liquid-state integral equation theory.

    PubMed

    Mrugalla, Florian; Kast, Stefan M

    2016-09-01

    Complex formation between molecules in solution is the key process by which molecular interactions are translated into functional systems. These processes are governed by the binding or free energy of association which depends on both direct molecular interactions and the solvation contribution. A design goal frequently addressed in pharmaceutical sciences is the optimization of chemical properties of the complex partners in the sense of minimizing their binding free energy with respect to a change in chemical structure. Here, we demonstrate that liquid-state theory in the form of the solute-solute equation of the reference interaction site model provides all necessary information for such a task with high efficiency. In particular, computing derivatives of the potential of mean force (PMF), which defines the free-energy surface of complex formation, with respect to potential parameters can be viewed as a means to define a direction in chemical space toward better binders. We illustrate the methodology in the benchmark case of alkali ion binding to the crown ether 18-crown-6 in aqueous solution. In order to examine the validity of the underlying solute-solute theory, we first compare PMFs computed by different approaches, including explicit free-energy molecular dynamics simulations as a reference. Predictions of an optimally binding ion radius based on free-energy derivatives are then shown to yield consistent results for different ion parameter sets and to compare well with earlier, orders-of-magnitude more costly explicit simulation results. This proof-of-principle study, therefore, demonstrates the potential of liquid-state theory for molecular design problems.

  17. Model-based conifer crown surface reconstruction from multi-ocular high-resolution aerial imagery

    NASA Astrophysics Data System (ADS)

    Sheng, Yongwei

    2000-12-01

    Tree crown parameters such as width, height, shape and crown closure are desirable in forestry and ecological studies, but they are time-consuming and labor intensive to measure in the field. The stereoscopic capability of high-resolution aerial imagery provides a way to crown surface reconstruction. Existing photogrammetric algorithms designed to map terrain surfaces, however, cannot adequately extract crown surfaces, especially for steep conifer crowns. Considering crown surface reconstruction in a broader context of tree characterization from aerial images, we develop a rigorous perspective tree image formation model to bridge image-based tree extraction and crown surface reconstruction, and an integrated model-based approach to conifer crown surface reconstruction. Based on the fact that most conifer crowns are in a solid geometric form, conifer crowns are modeled as a generalized hemi-ellipsoid. Both the automatic and semi-automatic approaches are investigated to optimal tree model development from multi-ocular images. The semi-automatic 3D tree interpreter developed in this thesis is able to efficiently extract reliable tree parameters and tree models in complicated tree stands. This thesis starts with a sophisticated stereo matching algorithm, and incorporates tree models to guide stereo matching. The following critical problems are addressed in the model-based surface reconstruction process: (1) the problem of surface model composition from tree models, (2) the occlusion problem in disparity prediction from tree models, (3) the problem of integrating the predicted disparities into image matching, (4) the tree model edge effect reduction on the disparity map, (5) the occlusion problem in orthophoto production, and (6) the foreshortening problem in image matching, which is very serious for conifer crown surfaces. Solutions to the above problems are necessary for successful crown surface reconstruction. The model-based approach was applied to recover the canopy surface of a dense redwood stand using tri-ocular high-resolution images scanned from 1:2,400 aerial photographs. The results demonstrate the approach's ability to reconstruct complicated stands. The model-based approach proposed in this thesis is potentially applicable to other surfaces recovering problems with a priori knowledge about objects.

  18. Influence of surface treatment on the in-vitro fracture resistance of zirconia-based all-ceramic anterior crowns.

    PubMed

    Schmitter, M; Lotze, G; Bömicke, W; Rues, S

    2015-12-01

    The purpose of this study was to assess the effect of surface treatment on the fracture resistance of zirconia-based all-ceramic anterior crowns. Sixty-four zirconia-based all-ceramic anterior crowns, veneered by use of a press-on technique, were produced. For 48 crowns intraoral adjustment was simulated (A-group), 16 crowns remained unadjusted (WA-group). The adjusted area was then treated in three ways: 1. no further surface treatment; 2. polishing, with irrigation, using polishers interspersed with diamond grit for ceramics; and 3. polishing and glaze firing. Half of the specimens were loaded until fracture in an universal testing device without artificial ageing; the other crowns underwent thermocycling and chewing simulation before ultimate-load testing. Explorative statistical analysis was performed by use of non-parametric and parametric tests. In addition, fracture-strength tests according to ISO 6872 were performed for veneer ceramic subjected to the different surface treatments. Finite element analysis was also conducted for the crowns, and surface roughness was measured. Crowns in the A-group were more sensitive to aging than crowns in the WA-group (p=0.038). Although both polishing and glaze firing slightly improved the fracture resistance of the specimens, the fracture resistance in the WA-group (initial fracture resistance (IFR): 652.0 ± 107.7N, remaining fracture resistance after aging (RFR): 560.6 ± 233.3N) was higher than the fracture resistance in the A-group (polished: IFR: 477.9 ± 108.8N, RFR: 386.0 ± 218.5N; glaze firing: IFR: 535.5 ± 128.0N, RFR: 388.6 ± 202.2N). Surface roughness without adjustment was Ra=0.1 μm; for adjustment but without further treatment it was Ra=1.4 μm; for adjustment and polishing it was Ra=0.3 μm; and for adjustment, polishing, and glazing it was Ra=0.6 μm. Stress distributions obtained by finite element analysis in combination with fracture strength tests showed that fractures most probably originated from the occlusal surface. To improve fracture resistance and reduce the incidence of failure, extensive occlusal adjustment of veneered anterior zirconia restorations should be avoided. Neither polishing nor glazing could restore the fracture resistance to the level maintained with unadjusted crowns. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. Retention of veneered stainless steel crowns on replicated typodont primary incisors: an in vitro study.

    PubMed

    Guelmann, Marcio; Gehring, Daren F; Turner, Clara

    2003-01-01

    The purpose of this in vitro study was to determine the effect of crimping and cementation on retention of veneered stainless steel crowns. One hundred twenty crowns, 90 from 3 commercially available brands of veneered stainless steel crowns (Dura Crown, Kinder Krown, and NuSmile Primary Crown) and 30 (plain) Unitek stainless steel crowns were assessed for retention. An orthodontic wire was soldered perpendicular to the incisal edge of the crowns; the crowns were fitted to acrylic replicas of ideal crown preparations and were divided equally into 3 test groups: group 1--crowns were crimped only (no cement used); group 2--crowns were cemented only; and group 3--crowns were crimped and cemented to the acrylic replicas. An Instron machine recorded the amount of force necessary to dislodge the crowns and the results were statistically analyzed using 2-way ANOVA and Tukey honestly significant difference (HSD) test. Group 3 was statistically more retentive than groups 1 and 2. Group 2 was statistically more retentive than group 1 (P < .001). In group 1, Unitek crowns were statistically more retentive than the veneered crowns (P < .05). In group 2, NuSmile crowns showed statistically less retention values than all other crowns (P < .05). In group 3,Kinder Krown crowns showed statistically better retention rates than all other brands (P < .05). Significantly higher retention values were obtained for all brands tested when crimping and cement were combined. The crowns with veneer facings were significantly more retentive than the nonveneered ones when cement and crimping were combined.

  20. Retrospective Study of Retention of Stainless Steel Crowns and Pre-veneered Crowns on Primary Anterior Teeth.

    PubMed

    Lopez-Loverich, Angela M; Garcia, Maria Minerva; Donly, Kevin J

    2015-01-01

    The purpose of this retrospective chart review was to explore the retention of anterior pre-veneered stainless steel crowns (NuSmile) and conventional stainless steel crowns (3M ESPE) placed on primary anterior teeth. Records for children were reviewed over four years using the electronic record system axiUm. Data collected included child's age at time of crown placement, date of placement, tooth number, type of crown, patient behavior, treatment environment, provider type, crown presence, absence, and cementation success or failure at subsequent recall visits. A total of 637 anterior crowns in children treated with either or both crown types met this study's inclusion criteria. Of these crowns, 483 were NuSmile Signature crowns and 154 were stainless steel crowns. There was a nine percent failure rate for the NuSmile Signature crowns and a seven percent failure rate for the stainless steel crowns. There was no statistically significant difference in crown retention rates between the two groups (P<0.05). A full-coverage restoration that can follow the lifespan of the primary anterior dentition in high-risk children is needed. The results from this study indicate good crown retention rates for both crown types with no statistically significant difference between them (P<0.05).

  1. A new look at a polar crown cavity as observed by SDO/AIA. Structure and dynamics

    NASA Astrophysics Data System (ADS)

    Régnier, S.; Walsh, R. W.; Alexander, C. E.

    2011-09-01

    Context. The Solar Dynamics Observatory (SDO) was launched in February 2010 and is now providing an unprecedented view of the solar activity at high spatial resolution and high cadence covering a broad range of temperature layers of the atmosphere. Aims: We aim at defining the structure of a polar crown cavity and describing its evolution during the erupting process. Methods: We use the high-cadence time series of SDO/AIA observations at 304 Å (50 000 K) and 171 Å (0.6 MK) to determine the structure of the polar crown cavity and its associated plasma, as well as the evolution of the cavity during the different phases of the eruption. We report on the observations recorded on 13 June 2010 located on the north-west limb. Results: We observe coronal plasma shaped by magnetic field lines with a negative curvature (U-shape) sitting at the bottom of a cavity. The cavity is located just above the polar crown filament material. We thus observe the inner part of the cavity above the filament as depicted in the classical three part coronal mass ejection (CME) model composed of a filament, a cavity, and a CME front. The filament (in this case a polar crown filament) is part of the cavity, and it makes a continuous structuring from the filament to the CME front depicted by concentric ellipses (in a 2D cartoon). Conclusions: We propose to define a polar crown cavity as a density depletion sitting above denser polar crown filament plasma drained down the cavity by gravity. As part of the polar crown filament, plasma at different temperatures (ranging from 50 000 K to 0.6 MK) is observed at the same location on the cavity dips and sustained by a competition between the gravity and the curvature of magnetic field lines. The eruption of the polar crown cavity as a solid body can be decomposed into two phases: a slow rise at a speed of 0.6 km s-1 and an acceleration phase at a mean speed of 25 km s-1. Two movies are only available at http://www.aanda.org

  2. Vertebral Formula in Red-Crowned Crane (Grus japonensis) and Hooded Crane (Grus monacha)

    PubMed Central

    HIRAGA, Takeo; SAKAMOTO, Haruka; NISHIKAWA, Sayaka; MUNEUCHI, Ippei; UEDA, Hiromi; INOUE, Masako; SHIMURA, Ryoji; UEBAYASHI, Akiko; YASUDA, Nobuhiro; MOMOSE, Kunikazu; MASATOMI, Hiroyuki; TERAOKA, Hiroki

    2013-01-01

    ABSTRACT Red-crowned cranes (Grus japonensis) are distributed separately in the east Eurasian Continent (continental population) and in Hokkaido, Japan (island population). The island population is sedentary in eastern Hokkaido and has increased from a very small number of cranes to over 1,300, thus giving rise to the problem of poor genetic diversity. While, Hooded cranes (Grus monacha), which migrate from the east Eurasian Continent and winter mainly in Izumi, Kagoshima Prefecture, Japan, are about eight-time larger than the island population of Red-crowned cranes. We collected whole bodies of these two species, found dead or moribund in eastern Hokkaido and in Izumi, and observed skeletons with focus on vertebral formula. Numbers of cervical vertebrae (Cs), thoracic vertebrae (Ts), vertebrae composing the synsacrum (Sa) and free coccygeal vertebrae (free Cos) in 22 Red-crowned cranes were 17 or 18, 9–11, 13 or 14 and 7 or 8, respectively. Total number of vertebrae was 47, 48 or 49, and the vertebral formula was divided into three types including 9 sub-types. Numbers of Cs, Ts, vertebrae composing the Sa and free Cos in 25 Hooded cranes were 17 or 18, 9 or 10, 12–14 and 6–8, respectively. Total number of vertebrae was 46, 47, 48 or 49, and the vertebral formula was divided into four types including 14 sub-types. Our findings clearly showed various numerical vertebral patterns in both crane species; however, these variations in the vertebral formula may be unrelated to the genetic diversity. PMID:24334828

  3. Resin composite repair for implant-supported crowns.

    PubMed

    Bonfante, Estevam A; Suzuki, Marcelo; Hirata, Ronaldo; Bonfante, Gerson; Fardin, Vinicius P; Coelho, Paulo G

    2017-08-01

    This study evaluated the reliability of implant-supported crowns repaired with resin composites. Fifty-four titanium abutments were divided in three groups (n = 18 each) to support resin nanoceramic molar crowns, as follows: (LU) (Lava Ultimate, 3M ESPE); LU repaired with either a direct or an indirect resin composite. Samples were subjected to mouth-motion accelerated-life testing in water (n = 18). Cumulative damage with a use stress of 300 N was used to plot Weibull curves for group comparison. Reliability was calculated for a mission of 100,000 cycles at 400 N load. Beta values were 0.83 for LU, 0.31 and 0.27 for LU repaired with Filtek and Ceramage, respectively. Weibull modulus for LU was 9.5 and η = 1047 N, m = 6.85, and η = 1002 N for LU repaired with Ceramage, and m = 4.65 and η = 766 N for LU repaired with Filtek (p < 0.10 between LU and LU repaired with Filtek). Reliability at 400 N was 100% for both LU and LU repaired with Ceramage which were significantly higher than LU Filtek repair (32%). LU restored crowns failed cohesively. Fractures were confined within the restored material, and detailed fractography is presented. The performance of resin nanoceramic material repaired with an indirect composite was maintained after accelerated-life testing compared to unrepaired controls. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1481-1489, 2017. © 2016 Wiley Periodicals, Inc.

  4. Retention of esthetic veneers on primary stainless steel crowns.

    PubMed

    Baker, L H; Moon, P; Mourino, A P

    1996-01-01

    The purpose of this study was to ascertain the amount of shearing force necessary to fracture, dislodge or deform the esthetic veneer facings of four commercially available veneered primary incisor stainless steel crowns. The four types tested were: Cheng Crowns, [Peter Cheng Orthodontic Laboratory]; Whiter Biter Crown II, [White Bite Inc.]; Kinder Krowns, [Mayclin Dental Studio, Inc]; and NuSmile Primary Crowns, [Orthodontic Technologies, Inc]. The crowns (#4 right central incisor) from each manufacturer were obtained with the facings attached. The crowns were soaked for ninety days and thermocycled at 4 degrees C and 55 degrees C for 500 45-second cycles. The crowns were cemented to standardized chromium cobalt metal dies. Each die was placed in to a custom holder on the Instron Universal testing machine. A force was applied at the incisal edge of the veneer at 148 degrees, (the primary interincisal angle), with a crosshead speed of 0.05 inches/minute until the veneer either fractured, dislodged or deformed. The mean force (Ibs) required +/- SD to produce failure, in descending order, was as follows: Cheng (107.8 +/- 17.3); NuSmile (100.2 +/- 18.2); KinderKrown (91.3 +/- 27.4)d Whiter Biter (81.5 +/- 21.7). To test the hypothesis of no difference among the four manufacturers, an analysis of variance was performed using PROC GLM. The resultant F statistic was 2.79 (p < 0.0543), indicating a marginally statistically significant difference in the response variable "pressure" among the four groups. A posthoc test was then performed to ascertain where these differences occurred. These results, using Turkey's studentized range test for pairwise comparisons, suggested that the only difference was between the Cheng and Whiter Biter manufacturers.

  5. The Effect of Coded Healing Abutments on Treatment Duration and Clinical Outcome: A Randomized Controlled Clinical Trial Comparing Encode and Conventional Impression Protocols.

    PubMed

    Abduo, Jaafar; Chen, Chen; Le Breton, Eugene; Radu, Alexandra; Szeto, Josephine; Judge, Roy; Darby, Ivan

    To compare the Encode impression protocol (Biomet 3i) with the conventional impression protocol in terms of treatment duration, clinical accuracy, and outcome up to the first postplacement review of single-implant crowns. A total of 45 implants were included in this study. The implants were randomly allocated to the Encode group (23 implants) or the conventional group (22 implants). At the time of surgery, all implants received two-piece Encode healing abutments. The implants were restored 3 months after insertion. In the conventional protocol, open-tray implant-level impressions were taken and the implants were restored with prefabricated abutments and porcelain-fused-to-metal (PFM) crowns. For the implants in the Encode group, closed-tray impressions of the healing abutments were taken. The generated casts were sent to the Biomet 3i scanning/milling center for custom abutment manufacturing on which PFM crowns were fabricated. Treatment duration (laboratory and clinical), clinical accuracy of occlusal and proximal contacts, and outcome (esthetics, patient satisfaction, and crown contour) were evaluated with the aid of a series of questionnaires. The Encode protocol required significantly less laboratory time (18 minutes) than the conventional protocol for adjustment of the abutments. The impression pour time, time for the laboratory to return the crown, time for crown insertion at the final appointment, and total clinical time for crown insertion did not differ significantly between the two protocols. Likewise, clinical accuracy, esthetics, and patient satisfaction were similar for the two protocols. The two protocols were clinically comparable. The Encode protocol is advantageous in reducing the laboratory time before crown fabrication.

  6. Comparison of Marginal Circumference of Two Different Pre-Crimped Stainless Steel Crowns for Primary Molars After Re-Crimping.

    PubMed

    Afshar, Hossein; Ghandehari, Mehdi; Soleimani, Banafsheh

    2015-12-01

    It is not clear what type of pre-crimped crown is more successful in achieving greater marginal adaptation following re-crimping. This study aimed to assess the changes in the circumference of 3M ESPE and MIB pre-crimped stainless steel crowns (SSCs) for the primary maxillary and mandibular first and second molars following re-crimping. This was an in-vitro, experimental study. Initial photographs were obtained from the margins of 3M and MIB SSCs for the upper and lower primary molars using a digital camera. Crown margins were crimped by applying 0.2N force using 114 and 137 pliers. Post-crimping photographs were also obtained and the changes in crown circumference after crimping were calculated using AutoCad software. The percentage of reduction in the circumference of crowns for each tooth was statistically analyzed based on the type of crown using student t-test. The effect of crown design and the associated teeth on the decreased circumference percentage was statistically analyzed by two-sided ANOVA. The percentage of reduction in lower E SSC circumference was 3.71±0.39% in MIB and 6.29±0.62% in 3M crowns. These values were 3.55±0.55% and 7.15±1.13% for the lower Ds, and 3.95±0.43 and 6.24±0.85% for the upper Ds, respectively. For the upper Es, these values were found to be 3.12±0.65% and 5.14±0.94%, respectively. For each tooth, a significant difference was found between MIB and 3M SSCs in terms of the percentage of reduction in crown circumference following crimping. The magnitude of this reduction was smaller in MIB compared to 3M SSCs (P<0.001). Considering the significant reduction in the marginal circumference of precrimped SSCs following re-crimping, it appears that this manipulation must be necessarily performed for MIB and 3M pre-crimped SSCs. By using 3M SSCs, higher marginal adaptation can be achieved following crimping.

  7. Comparison of Marginal Circumference of Two Different Pre-Crimped Stainless Steel Crowns for Primary Molars After Re-Crimping

    PubMed Central

    Afshar, Hossein; Ghandehari, Mehdi; Soleimani, Banafsheh

    2015-01-01

    Objectives: It is not clear what type of pre-crimped crown is more successful in achieving greater marginal adaptation following re-crimping. This study aimed to assess the changes in the circumference of 3M ESPE and MIB pre-crimped stainless steel crowns (SSCs) for the primary maxillary and mandibular first and second molars following re-crimping. Materials and Methods: This was an in-vitro, experimental study. Initial photographs were obtained from the margins of 3M and MIB SSCs for the upper and lower primary molars using a digital camera. Crown margins were crimped by applying 0.2N force using 114 and 137 pliers. Post-crimping photographs were also obtained and the changes in crown circumference after crimping were calculated using AutoCad software. The percentage of reduction in the circumference of crowns for each tooth was statistically analyzed based on the type of crown using student t-test. The effect of crown design and the associated teeth on the decreased circumference percentage was statistically analyzed by two-sided ANOVA. Results: The percentage of reduction in lower E SSC circumference was 3.71±0.39% in MIB and 6.29±0.62% in 3M crowns. These values were 3.55±0.55% and 7.15±1.13% for the lower Ds, and 3.95±0.43 and 6.24±0.85% for the upper Ds, respectively. For the upper Es, these values were found to be 3.12±0.65% and 5.14±0.94%, respectively. For each tooth, a significant difference was found between MIB and 3M SSCs in terms of the percentage of reduction in crown circumference following crimping. The magnitude of this reduction was smaller in MIB compared to 3M SSCs (P<0.001). Conclusion: Considering the significant reduction in the marginal circumference of precrimped SSCs following re-crimping, it appears that this manipulation must be necessarily performed for MIB and 3M pre-crimped SSCs. By using 3M SSCs, higher marginal adaptation can be achieved following crimping. PMID:27559353

  8. Effect of air-abrasion on the retention of zirconia ceramic crowns luted with different cements before and after artificial aging.

    PubMed

    Shahin, Ramez; Kern, Matthias

    2010-09-01

    The purpose of this in vitro study was to evaluate the effect of intaglio surface air-abrasion on the retention of CAD/CAM produced zirconia ceramic crowns cemented with three different types of cement. In addition the influence of artificial aging in masticatory simulator and thermocycling was tested. Extracted human premolars were prepared for all-ceramic crowns (12 degrees taper, 3 mm axial length). CAD/CAM zirconia crowns were manufactured. Half of the crowns were air-abraded with 50 microm alumina particles at 0.25 MPa, the rest was left as machined. The crowns were luted with zinc phosphate cement (Hoffmann), glass ionomer cement (Ketac Cem), or composite resin (Panavia 21), subgroups were either stored for 3 days in 37 degrees water bath or stored for 150 days in 37 degrees water bath, with additional 37,500 thermal cycles (5-55 degrees) and 300,000 cycles dynamic loading with 5 kg in a masticatory simulator. Then crown retention was measured in tension at a crosshead speed of 2 mm/min using a universal testing machine. Statistical analysis was performed with three-way ANOVA. Mean retention values were ranged from 2.8 to 7.1 MPa after 3 days and from 1.6 to 6.1 MPa after artificial aging. Air-abrasion significantly increased crown retention (p<0.001), while artificial aging decreased retention (p=0.017). In addition, the luting material had a significant influence on retention (p<0.001) with the adhesive luting resin providing the highest retention. The use of phosphate monomer containing composite resin on air-abraded zirconia ceramic can be recommended as most retentive luting method. Copyright 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Contrasting cDNA-AFLP profiles between crown and leaf tissues of cold-acclimated wheat plants indicate differing regulatory circuitries for low temperature tolerance.

    PubMed

    Ganeshan, Seedhabadee; Sharma, Pallavi; Young, Lester; Kumar, Ashwani; Fowler, D Brian; Chibbar, Ravindra N

    2011-03-01

    Low-temperature (LT) tolerance in winter wheat (Triticum aestivum L.) is an economically important but complex trait. Four selected wheat genotypes, a winter hardy cultivar, Norstar, a tender spring cultivar, Manitou and two near-isogenic lines with Vrn-A1 (spring Norstar) and vrn-A1 (winter Manitou) alleles of Manitou and Norstar were cold-acclimated at 6°C and crown and leaf tissues were collected at 0, 2, 14, 21, 35, 42, 56 and 70 days of cold acclimation. cDNA-AFLP profiling was used to determine temporal expression profiles of transcripts during cold-acclimation in crown and leaf tissues, separately to determine if LT regulatory circuitries in crown and leaf tissues could be delineated using this approach. Screening 64 primer combinations identified 4,074 and 2,757 differentially expressed transcript-derived fragments (TDFs) out of which 38 and 16% were up-regulated as compared to 3 and 6% that were down-regulated in crown and leaf tissues, respectively. DNA sequencing of TDFs revealed sequences common to both tissues including genes coding for DEAD-box RNA helicase, choline-phosphate cytidylyltransferase and delta-1-pyrroline carboxylate synthetase. TDF specific to crown tissues included genes coding for phospahtidylinositol kinase, auxin response factor protein and brassinosteroid insensitive 1-associated receptor kinase. In leaf, genes such as methylene tetrahydrofolate reductase, NADH-cytochrome b5 reductase and malate dehydrogenase were identified. However, 30 and 14% of the DNA sequences from the crown and leaf tissues, respectively, were hypothetical or unknown proteins. Cluster analysis of up-, down-regulated and unique TDFs, DNA sequence and real-time PCR validation, infer that mechanisms operating in crown and leaf tissue in response to LT are differently regulated and warrant further studies.

  10. Effects of Computer-Aided Manufacturing Technology on Precision of Clinical Metal-Free Restorations.

    PubMed

    Lee, Ki-Hong; Yeo, In-Sung; Wu, Benjamin M; Yang, Jae-Ho; Han, Jung-Suk; Kim, Sung-Hun; Yi, Yang-Jin; Kwon, Taek-Ka

    2015-01-01

    The purpose of this study was to investigate the marginal fit of metal-free crowns made by three different computer-aided design/computer-aided manufacturing (CAD/CAM) systems. The maxillary left first premolar of a dentiform was prepared for all-ceramic crown restoration. Thirty all-ceramic premolar crowns were made, ten each manufactured by the Lava system, Cercon, and Cerec. Ten metal ceramic gold (MCG) crowns served as control. The marginal gap of each sample was measured under a stereoscopic microscope at 75x magnification after cementation. One-way ANOVA and the Duncan's post hoc test were used for data analysis at the significance level of 0.05. The mean (standard deviation) marginal gaps were 70.5 (34.4) μm for the MCG crowns, 87.2 (22.8) μm for Lava, 58.5 (17.6) μm for Cercon, and 72.3 (30.8) μm for Cerec. There were no significant differences in the marginal fit among the groups except that the Cercon crowns had significantly smaller marginal gaps than the Lava crowns (P < 0.001). Within the limitation of this study, all the metal-free restorations made by the digital CAD/CAM systems had clinically acceptable marginal accuracy.

  11. Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns

    PubMed Central

    Buergers, Ralf; Ziebolz, Dirk; Roediger, Matthias

    2015-01-01

    PURPOSE This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: 5.9 ± 2.2 years), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required. PMID:26330981

  12. Comparison of the arithmetic and geometric means in estimating crown diameter and crown cross-sectional area

    Treesearch

    KaDonna Randolph

    2010-01-01

    The use of the geometric and arithmetic means for estimating tree crown diameter and crown cross-sectional area were examined for trees with crown width measurements taken at the widest point of the crown and perpendicular to the widest point of the crown. The average difference between the geometric and arithmetic mean crown diameters was less than 0.2 ft in absolute...

  13. Combined transuranic-strontium extraction process

    DOEpatents

    Horwitz, E.P.; Dietz, M.L.

    1992-12-08

    The transuranic (TRU) elements neptunium, plutonium and americium can be separated together with strontium from nitric acid waste solutions in a single process. An extractant solution of a crown ether and an alkyl(phenyl)-N,N-dialkylcarbanylmethylphosphine oxide in an appropriate diluent will extract the TRU's together with strontium, uranium and technetium. The TRU's and the strontium can then be selectively stripped from the extractant for disposal. 3 figs.

  14. Combined transuranic-strontium extraction process

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1992-01-01

    The transuranic (TRU) elements neptunium, plutonium and americium can be separated together with strontium from nitric acid waste solutions in a single process. An extractant solution of a crown ether and an alkyl(phenyl)-N,N-dialkylcarbanylmethylphosphine oxide in an appropriate diluent will extract the TRU's together with strontium, uranium and technetium. The TRU's and the strontium can then be selectively stripped from the extractant for disposal.

  15. Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results.

    PubMed

    Cooper, Lyndon F; Stanford, Clark; Feine, Jocelyne; McGuire, Michael

    2016-07-01

    Single-tooth implant restorations are commonly used to replace anterior maxillary teeth. The esthetic, functional, and biologic outcomes are, in part, a function of the abutment and crown. The purpose of this clinical study was to describe the implant, abutment, and crown survival and complication rates for CAD/CAM zirconia abutment and lithium disilicate crown restorations for single-tooth implants. As part of a broader prospective investigation that enrolled and treated 141 participants comparing tissue responses at the conical interface (CI; AstraTech OsseoSpeed), flat-to-flat interface (FI; NobelSpeedy), and platform-switch interface (PS; NanoTite Certain Prevail) of single-tooth implants, computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia abutments (ATLANTIS Abutment) and cemented lithium disilicate (e.max) crowns were used in the restoration of all implants. After 2.4 years in function (3 years after implant placement), the implant, abutment, and crown of 110 participants were evaluated. Technical and biologic complications were recorded. Demographic results were tabulated as percentages with mean values and standard deviations. Abutment survival was calculated with the Kaplan-Meier method. After 2.4 years, no abutments or crowns had been lost. Abutment complications (screw loosening, screw fracture, fracture) were absent for all 3 implant groups. Crown complications were limited to 2 crowns debonding and 1 with excess cement (2.5%). Five biological complications (4.0%) were recorded. The overall complication rate was 6.5%. CAD/CAM zirconia abutments restored with cemented lithium disilicate crowns demonstrated high survival on 3 different implant-abutment interface designs. No abutment or abutment screw fracture occurred. The technical complications observed after 2.4 years were minor and reversible. The use of CAD/CAM zirconia abutments with cemented lithium disilicate crowns is associated with high technical and biologic success at 2.4 years. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Preparation and characterization of chitosan membranes by using a combined freeze gelation and mild crosslinking method.

    PubMed

    Orrego, Carlos E; Valencia, Jesús S

    2009-02-01

    When gelification is performed by freezing-thawing repeated cycles, the resultant gel-like polymer systems are called cryogels. This work aims to assess the effect of the addition of glutaraldehyde and 18 Crown Ether-6 on surface properties and protein loading of dried chitosan cryogel films. Residual water content of treated chitosan membranes ranged between 11.93 and 13.86%, while their water activities vary from 0.5 to 0.7 (measured from 4 to 60 degrees C). Based on thermal data, water evaporation peak and degradation temperatures of chitosan membranes shifted to a higher temperature for crosslinked samples. X-ray diffractograms provide high values of crystallinity for all the samples (70.67-92.86%), the highest value being for the glutaraldehyde-treated membrane. Candida rugosa lipase can be immobilized successfully on chitosan membranes. Lipase immobilized on glutaraldehyde-crosslinked chitosan yielded the highest efficiency in terms of total coupled protein and protein loading efficiency.

  17. Resistance of full veneer metal crowns with different forms of axial grooves

    NASA Astrophysics Data System (ADS)

    Hidayat, A. S.; Masulili, C.; Indrasari, M.

    2017-08-01

    Dental crowns or bridges can occasionally come loose or separate from the tooth during chewing, particularly when they are situated on small, short, and conical teeth. The main cause of this separation is a lack of retention and resistance to the tooth. There are several methods available to increase the retention and resistance of the crown during both inlay and onlay preparation, including parallelism, groove preparation, crown build-up, and surface roughness. The aim of this study was to determine the differences in resistance of full veneer metal crowns with various forms of groove preparation. The study involved the compressive strength testing of a total of 24 specimens, namely six specimens without groove preparation, six specimens with box-shaped grooves, six specimens with V-shaped grooves, and six specimens with half round grooves. The mean values of the metal crowns that separated from the teeth during testing were 27.97 ± 1.08 kgF for the crowns with box-shaped grooves, 6.15 ± 0.22 kgF for those with V-shaped grooves, 1.77 ± 0.12 kgF for those with half round grooves, and 0.95 ± 0.13 kgF for those without grooves. This study found that the resistance is best in crowns with box-shaped grooves, followed by those with V-shaped grooves, half round grooves, and those without groove. When clinicians are working on short and conical molar teeth, it is therefore recommended that box-shaped grooves are used to increase the resistance of the crown.

  18. In vitro fracture resistance of three commercially available zirconia crowns for primary molars.

    PubMed

    Townsend, Janice A; Knoell, Patrick; Yu, Qingzhao; Zhang, Jian-Feng; Wang, Yapin; Zhu, Han; Beattie, Sean; Xu, Xiaoming

    2014-01-01

    The purpose of this study was to measure the fracture resistance of primary mandibular first molar zirconia crowns from three different manufacturers-EZ Pedo (EZP), NuSmile (NSZ), and Kinder Krowns (KK)-and compare it with the thickness of the zirconia crowns and the measured fracture resistance of preveneered stainless steel crowns (SSCs). The thickness of 20 zirconia crowns from three manufacturers were measured. The mean force required to fracture the crowns was determined. Preveneered NuSmile (NSW) SSCs were tested as a control. EZP crowns were significantly thicker in three of the six measured locations. The force required to fracture the EZP crown was significantly higher than that required for NSZ and KK. There was a positive correlation between fracture resistance and crown thickness in the mesial, distal, mesioocclusal, and distoocclusal dimensions. None of the zirconia crowns proved to be as resistant to fracture as the preveneered SSCs. Statistically significant differences were found among the forces required to fracture zirconia crowns by three different manufacturers. The increase in force correlated with crown thickness. The forces required to fracture the preveneered stainless steel crowns were greater than the forces required to fracture all manufacturers' zirconia crowns.

  19. Development of new solid-phase microextraction fibers by sol-gel technology for the determination of organophosphorus pesticide multiresidues in food.

    PubMed

    Yu, Jianxin; Wu, Caiying; Xing, Jun

    2004-05-21

    Allyloxy bisbenzo 16-crown-5 trimethoxysilane was first used as precursor to prepare the sol-gel-derived bisbenzo crown ether/hydroxyl-terminated silicone oil (OH-TSO) SPME coating. The coating procedure involving sol solution composition and conditioning process was presented. Compared with commercial SPME stationary phases, the new coatings showed higher extraction efficiency and therefore could provide higher sensitivity for organphosphorous pesticides (OPs). Limits of detection (LODs) were in the range of 0.003-1.0 ng/g for these OPs in food samples (honey, juice, orange and pakchoi). The optimal extraction conditions of the new coatings to OPs in these samples were investigated by adjusting extraction time, salt addition, extraction temperature, and dilution ratios of samples with distilled water by using SPME coupled with gas chromatography (GC)-flame photometric detection (FPD). The method was applied to determine the concentrations of OPs in real samples.

  20. [Preliminary evaluation of plastic crown restoration supported by osseointegrated implants].

    PubMed

    Huang, J; Zhang, K

    1997-08-01

    This study was to evaluate the feasibility of plastic crown restoration supported by osseointegrated implants. The following conclusions were drawn from this study: plastic crown gave better biomechanical consideration than porcelain fused to metal (PFM) crown in osseointegrated prostheses, but plastic crown gave worse wearability, tensile strength, compression strength and flexuaral strength than PFM crown. After restoration the disadvantages of the plastic crown were beyond the clinical acceptable range. It showed plastic crown designed dental prothetic implantation was unfeasible.

  1. [Three-dimensional data fusion method for tooth crown and root based on curvature continuity algorithm].

    PubMed

    Zhao, Y J; Liu, Y; Sun, Y C; Wang, Y

    2017-08-18

    To explore a three-dimensional (3D) data fusion and integration method of optical scanning tooth crowns and cone beam CT (CBCT) reconstructing tooth roots for their natural transition in the 3D profile. One mild dental crowding case was chosen from orthodontics clinics with full denture. The CBCT data were acquired to reconstruct the dental model with tooth roots by Mimics 17.0 medical imaging software, and the optical impression was taken to obtain the dentition model with high precision physiological contour of crowns by Smart Optics dental scanner. The two models were doing 3D registration based on their common part of the crowns' shape in Geomagic Studio 2012 reverse engineering software. The model coordinate system was established by defining the occlusal plane. crown-gingiva boundary was extracted from optical scanning model manually, then crown-root boundary was generated by offsetting and projecting crown-gingiva boundary to the root model. After trimming the crown and root models, the 3D fusion model with physiological contour crown and nature root was formed by curvature continuity filling algorithm finally. In the study, 10 patients with dentition mild crowded from the oral clinics were followed up with this method to obtain 3D crown and root fusion models, and 10 high qualification doctors were invited to do subjective evaluation of these fusion models. This study based on commercial software platform, preliminarily realized the 3D data fusion and integration method of optical scanning tooth crowns and CBCT tooth roots with a curvature continuous shape transition. The 10 patients' 3D crown and root fusion models were constructed successfully by the method, and the average score of the doctors' subjective evaluation for these 10 models was 8.6 points (0-10 points). which meant that all the fusion models could basically meet the need of the oral clinics, and also showed the method in our study was feasible and efficient in orthodontics study and clinics. The method of this study for 3D crown and root data fusion could obtain an integrate tooth or dental model more close to the nature shape. CBCT model calibration may probably improve the precision of the fusion model. The adaptation of this method for severe dentition crowding and micromaxillary deformity needs further research.

  2. INFLUENCE OF DIFFERENT CANTILEVER EXTENSIONS AND GLASS OR POLYARAMID REINFORCEMENT FIBERS ON FRACTURE STRENGTH OF IMPLANT-SUPPORTED TEMPORARY FIXED PROSTHESIS

    PubMed Central

    Colán Guzmán, Paola; de Freitas, Fernando Furtado Antunes; Ferreira, Paulo Martins; de Freitas, César Antunes; Reis, Kátia Rodrigues

    2008-01-01

    In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups. PMID:19089201

  3. Influence of different cantilever extensions and glass or polyaramide reinforcement fibers on fracture strength of implant-supported temporary.

    PubMed

    Colán Guzmán, Paola; Freitas, Fernando Furtado Antunes de; Ferreira, Paulo Martins; Freitas, César Antunes de; Reis, Kátia Rodrigues

    2008-01-01

    In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.

  4. Lithium Ion Recognition with Nanofluidic Diodes through Host-Guest Complexation in Confined Geometries.

    PubMed

    Ali, Mubarak; Ahmed, Ishtiaq; Ramirez, Patricio; Nasir, Saima; Mafe, Salvador; Niemeyer, Christof M; Ensinger, Wolfgang

    2018-05-15

    The lithium ion recognition is receiving significant attention because of its application in pharmaceuticals, lubricants and, especially, in energy technology. We present a nanofluidic device for specific lithium ion recognition via host-guest complexation in a confined environment. A lithium-selective receptor molecule, the aminoethyl-benzo-12-crown-4 (BC12C4-NH 2 ), is designed and functionalized on single conical nanopores in polyethylene terephthalate (PET) membranes. The native carboxylic acid groups on the pore walls are covalently linked with the crown ether moieties and the process is monitored from the changes in the current-voltage ( I- V) curves. The B12-crown-4 moieties are known to specifically bind with lithium ions and when the modified pore is exposed to different alkali metal chloride solutions separately, significant changes in the ion current and rectification are only observed for lithium chloride. This fact suggests the generation of positively charged B12C4-Li + complexes on the pore surface. Furthermore, the nanofluidic diode is able to recognize the lithium ion even in the presence of high concentrations of potassium ions in the external electrolyte solution. Thus, this nanodevice suggests a strategy to miniaturize nanofluidic porous systems for efficient recognition, extraction, and separation of lithium from raw materials.

  5. Estimating the weight of crown segments for old-growth Douglas-fir and western hemlock.

    Treesearch

    J.A. Kendall Snell; Timothy A. Max

    1985-01-01

    The purpose of this study was to develop and validate estimators to predict total crown weight and weight of any segment of crown for old-growth felled and bucked Douglas-fir and western hemlock trees. Equations were developed for predicting weight of continuous live crown, total live crown, dead crown, any segment of live crown, and individual branches for old-growth...

  6. Crown Position and Light Exposure Classification-An Alternative to Field-Assigned Crown Class

    Treesearch

    William A. Bechtold

    2003-01-01

    Crown class, an ordinal tree-level mensuration attribute used extensively by foresters, is difficult to assign in the field because definitions of individual classes are confounded by ambiguous references to the position the tree in the canopy and amount of light received by its crown. When crown class is decomposed into its two elements-crown position and crown light...

  7. Preformed posterior stainless steel crowns: an update.

    PubMed

    Croll, T P

    1999-02-01

    For almost 50 years, dentists have used stainless steel crowns for primary and permanent posterior teeth. No other type of restoration offers the convenience, low cost, durability, and reliability of such crowns when interim full-coronal coverage is required. Preformed stainless steel crowns have improved over the years. Better luting cements have been developed and different methods of crown manipulation have evolved. This article reviews stainless steel crown procedures for primary and permanent posterior teeth. Step-by-step placement of a primary molar stainless steel crown is documented and permanent molar stainless steel crown restoration is described. A method for repairing a worn-through crown also is reviewed.

  8. Influence of micro-topography and crown characteristics on tree height estimations in tropical forests based on LiDAR canopy height models

    NASA Astrophysics Data System (ADS)

    Alexander, Cici; Korstjens, Amanda H.; Hill, Ross A.

    2018-03-01

    Tree or canopy height is an important attribute for carbon stock estimation, forest management and habitat quality assessment. Airborne Laser Scanning (ALS) based on Light Detection and Ranging (LiDAR) has advantages over other remote sensing techniques for describing the structure of forests. However, sloped terrain can be challenging for accurate estimation of tree locations and heights based on a Canopy Height Model (CHM) generated from ALS data; a CHM is a height-normalised Digital Surface Model (DSM) obtained by subtracting a Digital Terrain Model (DTM) from a DSM. On sloped terrain, points at the same elevation on a tree crown appear to increase in height in the downhill direction, based on the ground elevations at these points. A point will be incorrectly identified as the treetop by individual tree crown (ITC) recognition algorithms if its height is greater than that of the actual treetop in the CHM, which will be recorded as the tree height. In this study, the influence of terrain slope and crown characteristics on the detection of treetops and estimation of tree heights is assessed using ALS data in a tropical forest with complex terrain (i.e. micro-topography) and tree crown characteristics. Locations and heights of 11,442 trees based on a DSM are compared with those based on a CHM. The horizontal (DH) and vertical displacements (DV) increase with terrain slope (r = 0.47 and r = 0.54 respectively, p < 0.001). The overestimations in tree height are up to 16.6 m on slopes greater than 50° in our study area in Sumatra. The errors in locations (DH) and tree heights (DV) are modelled for trees with conical and spherical tree crowns. For a spherical tree crown, DH can be modelled as R sin θ, and DV as R (sec θ - 1). In this study, a model is developed for an idealised conical tree crown, DV = R (tan θ - tan ψ), where R is the crown radius, and θ and ψ are terrain and crown angles respectively. It is shown that errors occur only when terrain angle exceeds the crown angle, with the horizontal displacement equal to the crown radius. Errors in location are seen to be greater for spherical than conical trees on slopes where crown angles of conical trees are less than the terrain angle. The results are especially relevant for biomass and carbon stock estimations in tropical forests where there are trees with large crown radii on slopes.

  9. Deformation of crowns during cementation.

    PubMed

    Wilson, P R; Goodkind, R J; Delong, R; Sakaguchi, R

    1990-11-01

    Deformation of crowns during cementation was investigated by a simple loading system of defined crowns with silicone fluids as cements. Deformation of the crowns was measured by long stain gauges that encircled the cervical margins. Die spacing was simulated by etching the die. Venting was simulated by removing a small screw. Deformation of the crowns was decreased by decreasing the viscosity of fluid, increasing the thickness of the crowns, and venting. Etching the die decreased the seating times of the crowns, but did not alter the level of deformation. Terminal cementation with zinc phosphate cement confirmed the presence of crown deformation during cementation. The results have consequences for bonded and all-ceramic crowns, and explain several clinical phenomena. It is suggested that low viscosity cements, low seating forces, and die spacing be used to decrease the deformation of crowns during seating. The importance of passive fitting of the crown to the tooth is stressed.

  10. Absorption of nickel, chromium, and iron by the root surface of primary molars covered with stainless steel crowns.

    PubMed

    Keinan, David; Mass, Eliyahu; Zilberman, Uri

    2010-01-01

    Objective. The purpose of this study was to analyze the absorption of metal ions released from stainless steel crowns by root surface of primary molars. Study Design. Laboratory research: The study included 34 primary molars, exfoliated or extracted during routine dental treatment. 17 molars were covered with stainless-steel crowns for more than two years and compared to 17 intact primary molars. Chemical content of the mesial or distal root surface, 1 mm apically to the crown or the cemento-enamel junction (CEJ), was analyzed. An energy dispersive X-ray spectrometer (EDS) was used for chemical analysis. Results. Higher amounts of nickel, chromium, and iron (5-6 times) were found in the cementum of molars covered with stainless-steel crowns compared to intact molars. The differences between groups were highly significant (P < .001). Significance. Stainless-steel crowns release nickel, chromium, and iron in oral environment, and the ions are absorbed by the primary molars roots. The additional burden of allergenic metals should be reduced if possible.

  11. Determination of the mental foramen position in dental radiographs in 18-30 year olds.

    PubMed

    Currie, Charlotte C; Meechan, John G; Whitworth, John M; Carr, Andrew; Corbett, Ian P

    2016-01-01

    To determine the radiographic position and reliability of assessing mental foramen (MF) position in relation to premolar crowns in an 18- to 30-year-old UK-based population. Following ethical approval and a power calculation, the position of the MF was recorded in relation to premolar crowns and apices in 100 dental panoramic tomographs. Positions were assessed by three senior clinicians independently, then by consensus. Data were analysed using descriptive statistics, χ(2) and Fleiss' and Cohen's kappa. Reliability data showed only fair to moderate agreement on independent scoring. Substantial to almost perfect agreement was achieved by consensus, demonstrating the most common position for the MF to be between the first and second premolar teeth when using both premolar crowns (51%) and apices (76%) as reference points. There was a significant difference in the position of the foramen between the left and right sides (p < 0.05), with only 62% of cases showing symmetry. The most common position for the MF is between the first and second premolar teeth; however, anatomical variation is seen. Use of pre-operative radiographs to relate the position of the MF to premolar crowns may not be reliable.

  12. Rubric system for evaluation of crown preparation performed by dental students.

    PubMed

    Habib, S R

    2018-03-01

    This study aimed to investigate the use of an analytic rubric system for the evaluation of all-ceramic crown preparation on the right maxillary central incisor performed by the dental students. Seventy-two-third-year students and 8 faculty members from prosthodontics participated in this double-blind study. The students prepared an ivorine tooth # 11 for all-ceramic crown. The students were given clear instructions regarding the all-ceramic crown preparation and informed about the criteria for the assessment of the preparation. An analytic rubric based on 10-point scale for assessment of various preparation parameters was used by the 8 examiners. Descriptive statistics, ANOVA and post hoc Tukey tests were used for statistical analysis. One-way analysis of variance indicated significance amongst the examiners for all the parameters except for time management. The overall mean scoring by examiners was 7.60 ± 1.18, with highest and lowest mean scores for Examiner 1 (8.02 ± 1.06) and Examiner 4 (6.82 ± 1.50), respectively. The highest number of interexaminer variation (difference) in scoring was found for two plane reduction, and the least difference amongst the examiners was observed for finishing of margins and walls of the preparation. Examiner 4 had the highest number of significant difference with the rest of the examiners. The students scored least marks in axial reduction (56.33%) and preservation of adjacent teeth (66.9%). Criteria-based assessment using analytic rubric for crown preparations in pre-clinical fixed prosthodontics is an effective tool for finding the errors/weak areas of dental students. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. The use of functionally graded dental crowns to improve biocompatibility: a finite element analysis.

    PubMed

    Mahmoudi, Mojtaba; Saidi, Ali Reza; Hashemipour, Maryam Alsadat; Amini, Parviz

    2018-02-01

    In post-core crown restorations, the significant mismatch between stiffness of artificial crowns and dental tissues leads to stress concentration at the interfaces. The aim of the present study was to reduce the destructive stresses by using a class of inhomogeneous materials called functionally graded materials (FGMs). For the purpose of the study, a 3-dimentional computer model of a premolar tooth and its surrounding tissues were generated. A post-core crown restoration with various crown materials, homogenous and FGM materials, were simulated and analyzed by finite element method. Finite element and statistical analysis showed that, in case of oblique loading, a significant difference (p < 0.05) was found at the maximum von Mises stresses of the crown margin between FGM and homogeneous crowns. The maximum von Mises stresses of the crown margin generated by FGM crowns were lower than those generated by homogenous crowns (70.8 vs. 46.3 MPa) and alumina crown resulted in the highest von Mises stress at the crown margin (77.7 MPa). Crown materials of high modulus of elasticity produced high stresses at the cervical region. FGM crowns may reduce the stress concentration at the cervical margins and consequently reduce the possibility of fracture.

  14. Influence of cement film thickness on the retention of implant-retained crowns.

    PubMed

    Mehl, Christian; Harder, Sönke; Steiner, Martin; Vollrath, Oliver; Kern, Matthias

    2013-12-01

    The main goal of this study was to establish a new, high precision procedure to evaluate the influence of cement film thickness on the retention of cemented implant-retained crowns. Ninety-six tapered titanium abutments (6° taper, 4.3 mm diameter, Camlog) were shortened to 4 mm. Computer-aided design was used to design the crowns, and selective laser sintering, using a cobalt-chromium alloy, was used to produce the crowns. This method used a focused high-energy laser beam to fuse a localized region of metal powder to build up the crowns gradually. Before cementing, preset cement film thicknesses of 15, 50, 80, or 110 μm were established. Glass ionomer, polycarboxylate, or resin cements were used for cementation. After 3 days storage in demineralized water, the retention of the crowns was measured in tension using a universal testing machine. The cement film thicknesses could be achieved with a high level of precision. Interactions between the factors cement and cement film thickness could be found (p ≤ 0.001). For all cements, crown retention decreased significantly between a cement film thickness of 15 and 50 μm (p ≤ 0.001). At 15 μm cement film thickness, the resin cement was the most retentive cement, followed by the polycarboxylate and then the glass ionomer cement (p ≤ 0.05). The results suggest that cement film thickness has an influence on the retentive strength of cemented implant-retained crowns. © 2013 by the American College of Prosthodontists.

  15. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1994-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  16. Hydrogen-bonding interactions and protic equilibria in room-temperature ionic liquids containing crown ethers.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marin, T.; Shkrob, I.; Dietz, M.

    2011-04-14

    Nuclear magnetic resonance (NMR) spectroscopy has been used to study hydrogen-bonding interactions between water, associated and dissociated acids (i.e., nitric and methanesulfonic acids), and the constituent ions of several water-immiscible room-temperature ionic liquids (ILs). In chloroform solutions also containing a crown ether (CE), water molecules strongly associate with the IL ions, and there is rapid proton exchange between these bound water molecules and hydronium associated with the CE. In neat ILs, the acids form clusters differing in their degree of association and ionization, and their interactions with the CEs are weak. The CE can either promote proton exchange between differentmore » clusters in IL solution when their association is weak or inhibit such exchange when the association is strong. Even strongly hydrophobic ILs are shown to readily extract nitric acid from aqueous solution, typically via the formation of a 1:1:1 {l_brace}H{sub 3}O{sup +} {center_dot} CE{r_brace}NO{sub 3}{sup -} complex. In contrast, the extraction of methanesulfonic acid is less extensive and proceeds mainly by IL cation-hydronium ion exchange. The relationship of these protic equilibria to the practical application of hydrophobic ILs (e.g., in spent nuclear fuel reprocessing) is discussed.« less

  17. Conjugated Porphyrin Dimers: Cooperative Effects and Electronic Communication in Supramolecular Ensembles with C60.

    PubMed

    Moreira, Luis; Calbo, Joaquín; Aragó, Juan; Illescas, Beatriz M; Nierengarten, Iwona; Delavaux-Nicot, Béatrice; Ortí, Enrique; Martín, Nazario; Nierengarten, Jean-François

    2016-11-30

    Two new conjugated porphyrin-based systems (dimers 3 and 4) endowed with suitable crown ethers have been synthesized as receptors for a fullerene-ammonium salt derivative (1). Association constants in solution have been determined by UV-vis titration experiments in CH 2 Cl 2 at room temperature. The designed hosts are able to associate up to two fullerene-based guest molecules and present association constants as high as ∼5 × 10 8 M -1 . Calculation of the allosteric cooperative factor α for supramolecular complexes [3·1 2 ] and [4·1 2 ] showed a negative cooperative effect in both cases. The interactions accounting for the formation of the associates are based, first, on the complementary ammonium-crown ether interaction and, second, on the π-π interactions between the porphyrin rings and the C 60 moieties. Theoretical calculations have evidenced a significant decrease of the electron density in the porphyrin dimers 3 and 4 upon complexation of the first C 60 molecule, in good agreement with the negative cooperativity found in these systems. This negative effect is partially compensated by the stabilizing C 60 -C 60 interactions that take place in the more stable syn-disposition of [4·1 2 ].

  18. High performance planar p-i-n perovskite solar cells with crown-ether functionalized fullerene and LiF as double cathode buffer layers

    NASA Astrophysics Data System (ADS)

    Liu, Xiaodong; Lei, Ming; Zhou, Yi; Song, Bo; Li, Yongfang

    2015-08-01

    Double cathode buffer layers (CBLs) composed of fullerene derivative functionalized with a crown-ether end group in its side chain (denoted as PCBC) and a LiF layer were introduced between the PCBM acceptor layer and the top cathode in planar p-i-n perovskite solar cells (pero-SCs) based on CH3NH3PbI3-XClX. The devices with the PCBC/LiF double CBLs showed significant improvements in power conversion efficiency (PCE) and long-term stability when compared to the device with LiF single CBL. Through optimizing the spin-coating speed of PCBC, a maximum PCE of 15.53% has been achieved, which is approximately 15% higher than that of the device with single LiF CBL. The remarkable improvement in PCE can be attributed to the formation of a better ohmic contact in the CBL between PCBC and LiF/Al electrode arising from the dipole moment of PCBC, leading to the enhanced fill factor and short-circuit current density (Jsc). Besides the PCE, the long-term stability of the devices with PCBC interlayer is also superior to that of the device with LiF single CBL, which is due to the more effective protection for the perovskite/PCBM interface.

  19. Detecting Forests Damaged by Pine Wilt Disease at the Individual Tree Level Using Airborne Laser Data and WORLDVIEW-2/3 Images Over Two Seasons

    NASA Astrophysics Data System (ADS)

    Takenaka, Y.; Katoh, M.; Deng, S.; Cheung, K.

    2017-10-01

    Pine wilt disease is caused by the pine wood nematode (Bursaphelenchus xylophilus) and Japanese pine sawyer (Monochamus alternatus). This study attempted to detect damaged pine trees at different levels using a combination of airborne laser scanning (ALS) data and high-resolution space-borne images. A canopy height model with a resolution of 50 cm derived from the ALS data was used for the delineation of tree crowns using the Individual Tree Detection method. Two pan-sharpened images were established using the ortho-rectified images. Next, we analyzed two kinds of intensity-hue-saturation (IHS) images and 18 remote sensing indices (RSI) derived from the pan-sharpened images. The mean and standard deviation of the 2 IHS images, 18 RSI, and 8 bands of the WV-2 and WV-3 images were extracted for each tree crown and were used to classify tree crowns using a support vector machine classifier. Individual tree crowns were assigned to one of nine classes: bare ground, Larix kaempferi, Cryptomeria japonica, Chamaecyparis obtusa, broadleaved trees, healthy pines, and damaged pines at slight, moderate, and heavy levels. The accuracy of the classifications using the WV-2 images ranged from 76.5 to 99.6 %, with an overall accuracy of 98.5 %. However, the accuracy of the classifications using the WV-3 images ranged from 40.4 to 95.4 %, with an overall accuracy of 72 %, which suggests poorer accuracy compared to those classes derived from the WV-2 images. This is because the WV-3 images were acquired in October 2016 from an area with low sun, at a low altitude.

  20. Significance of crown shape in the replacement of a central incisor with a single implant-supported crown.

    PubMed

    Gobbato, Luca; Paniz, Gianluca; Mazzocco, Fabio; Chierico, Andrea; Tsukiyama, Teppei; Levi, Paul A; Weisgold, Arnold S

    2013-05-01

    When utilizing a single implant-supported crown to replace a central incisor, understanding the final shape of the implant restoration is an important factor to help achieve a successful esthetic outcome. In today's dentistry, tooth shape is a critical factor when dental implant prostheses are considered in the esthetic zone. The major esthetic goal for this type of restoration is to achieve the closest possible symmetry with the adjacent tooth, both at the soft and at the hard tissue levels. The goal of this study was to objectively analyze the significance of natural crown shape when replacing a central incisor with a single implant-supported crown. In this study, we investigated the shape of the crowns of maxillary central incisors in 60 individuals who presented to our clinics with an untreatable central incisor. The presence of a dental diastema, "black triangle," presence or absence of gingival symmetry, and the presence or absence of dental symmetry were recorded in the pre- and postoperative photographs. Out of 60 patients, 33.3% had triangular-shaped crowns, 16.6% square/tapered, and 50% square-shaped crown form. After treatment was rendered, 65% of the triangular group, 40% of the square/tapered group, and 13.3% of the square group required an additional restoration on the adjacent central incisor in order to fulfill the esthetic needs of the patients. Data analysis revealed that if there is a "black triangle," a diastema, or presence of dental or gingival asymmetry, an additional restoration on the adjacent central incisor is often required in order to fulfill esthetic goals. The additional restoration is highly recommended in situations with a triangular crown shape, while it is suggested in cases of square/tapered and square tooth shapes in the presence of a dental diastema.

  1. In vitro evaluation of the marginal integrity of CAD/CAM interim crowns.

    PubMed

    Kelvin Khng, Kwang Yong; Ettinger, Ronald L; Armstrong, Steven R; Lindquist, Terry; Gratton, David G; Qian, Fang

    2016-05-01

    The accuracy of interim crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems has not been well investigated. The purpose of this in vitro study was to evaluate the marginal integrity of interim crowns made by CAD/CAM compared with that of conventional polymethylmethacrylate (PMMA) crowns. A dentoform mandibular left second premolar was prepared for a ceramic crown and scanned for the fabrication of 60 stereolithical resin dies, half of which were scanned to fabricate 15 Telio CAD-CEREC and 15 Paradigm MZ100-E4D-E4D crowns. Fifteen Caulk and 15 Jet interim crowns were made on the remaining resin dies. All crowns were cemented with Tempgrip under a 17.8-N load, thermocycled for 1000 cycles, placed in 0.5% acid fuschin for 24 hours, and embedded in epoxy resin before sectioning from the mid-buccal to mid-lingual surface. The marginal discrepancy was measured using a traveling microscope, and dye penetration was measured as a percentage of the overall length under the crown. The mean vertical marginal discrepancy of the conventionally made interim crowns was greater than for the CAD/CAM crowns (P=.006), while no difference was found for the horizontal component (P=.276). The mean vertical marginal discrepancy at the facial surface of the Caulk crowns was significantly greater than that of the other 3 types of interim crowns (P<.001). At the facial margin, the mean horizontal component of the Telio crowns was significantly larger than that of the other 3 types, with no difference at the lingual margins (P=.150). The mean percentage dye penetration for the Paradigm MZ100-E4D crowns was significantly greater and for Jet crowns significantly smaller than for the other 3 crowns (P<.001). However, the mean percentage dye penetration was significantly correlated with the vertical and horizontal marginal discrepancies of the Jet interim crowns at the facial surface and with the horizontal marginal discrepancies of the Caulk interim crowns at the lingual surface (P<.01 in each instance). A significantly smaller vertical marginal discrepancy was found with the interim crowns fabricated by CAD/CAM as compared with PMMA crowns; however, this difference was not observed for the horizontal component. The percentage dye penetration was correlated with vertical and horizontal discrepancies at the facial surface for the Jet interim crowns and with horizontal discrepancies at the lingual surface for the Caulk interim crowns. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Tree crown conditions in Missouri, 2000-2003

    Treesearch

    KaDonna C. Randolph; W. Keith Moser

    2009-01-01

    The Forest Service, U.S. Department of Agriculture, Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes three FIA tree crown condition indicators (crown dieback, crown density, and foliage transparency) and sapling crown vigor measured in Missouri between 2000...

  3. Descriptive statistics of tree crown condition in the Northeastern United States

    Treesearch

    KaDonna C. Randolph; Randall S. Morin; Jim Steinman

    2010-01-01

    The U.S. Forest Service Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes four crown condition indicators (crown dieback, crown density, foliage transparency, and sapling crown vigor) measured in Connecticut, Delaware, Maine, Maryland, Massachusetts, New...

  4. [Influence of SiO2 films on color reproduction of Ni-Cr alloy porcelain crowns].

    PubMed

    Wu, Dong; Feng, Yunzhi

    2011-08-01

    To study whether SiO2 films will influence the color of Ni-Cr metal ceramic restorations. For the film plating experimental group, Sol-gel method was employed to apply SiO2 films to the surface of the Ni-Cr copings, while no coating was applied for the non-film-plating control group. Veneering porcelains were then applied subsequently, and a total of 12 B2-colored maxillary incisor metal ceramic crowns were fabricated with 6 crowns in each group. A ShadeEye Ncc computer-aided colorimeter was employed to measure the shade of the samples, as well as 6 B2(Vitapan classical vita color tabs) shade standards. The color was expressed as C1E-1976-Lab coordinates. There was a statistically significant color difference between all metal ceramic crowns and the B2 shade standards (delta E>1.5). The L*, a*, b* values of all crowns were higher than those of the B2 shade standards, and the crowns were typically yellower or redder. While neither significant color difference nor difference in shade values was observed between the film plating experimental group and non-film-plating control group (delta E<1.5). SiO2 films applied to the Ni-Cr copings by means of Sol-gel technique do not impact the final color of the metal ceramic restorations.

  5. Fracture strength and fatigue resistance of all-ceramic molar crowns manufactured with CAD/CAM technology.

    PubMed

    Zahran, Mohammed; El-Mowafy, Omar; Tam, Laura; Watson, Philip A; Finer, Yoav

    2008-07-01

    All-ceramic crowns are subject to fracture during function, especially in the posterior area. The use of yttrium-stabilized zirconium-oxide ceramic as a substructure for all-ceramic crowns to improve fracture resistance is unproven. The aim of this study was to compare fracture strength and fatigue resistance of new zirconium-oxide and feldspathic all-ceramic crowns made with computer-aided design/computer-aided manufacturing (CAD/CAM). An ivorine molar was prepared to receive an all-ceramic crown. Using epoxy resin, 40 replication dies were made of the prepared tooth. Twenty feldspathic all-ceramic crowns (Vita Mark II) (VMII) and 20 zirconium-oxide crown copings (In-Ceram YZ) (YZ) were made using CAD/CAM technique (CEREC-3D). The YZ copings were sintered and veneered manually with a fine-particle ceramic (VM9). All crowns were cemented to their respective dies using resin cement (Panavia F 2.0). Ten crowns in each group were subjected to compressive fatigue loading in a universal testing machine (instron). The other ten crowns from each group were loaded to fracture at a crosshead speed of 1 mm/min. Data were statistically analyzed using independent t-test and Fisher's exact test at alpha= 0.05. There was a significant difference between the survival rates of the two materials during the fatigue test (p < 0.001). All VMII crowns survived without any crack formation, while all YZ crowns fractured (40%) or developed cracks (60%). All the YZ crown fractures occurred within the veneering layer during the fatigue test. There was no significant difference in mean fracture load between the two materials (p= 0.268). Mean fracture loads (standard deviation) in N were: 1459 (492) for YZ crowns and 1272 (109) for VMII crowns. The performance of VMII crowns was superior to YZ crowns in the fatigue test. The premature fractures and cracks of the YZ crowns were attributed to weakness in the YZ veneer layer or in the core/veneer bond.

  6. Fatigue Failure of External Hexagon Connections on Cemented Implant-Supported Crowns.

    PubMed

    Malta Barbosa, João; Navarro da Rocha, Daniel; Hirata, Ronaldo; Freitas, Gileade; Bonfante, Estevam A; Coelho, Paulo G

    2018-01-17

    To evaluate the probability of survival and failure modes of different external hexagon connection systems restored with anterior cement-retained single-unit crowns. The postulated null hypothesis was that there would be no differences under accelerated life testing. Fifty-four external hexagon dental implants (∼4 mm diameter) were used for single cement-retained crown replacement and divided into 3 groups: (3i) Full OSSEOTITE, Biomet 3i (n = 18); (OL) OEX P4, Osseolife Implants (n = 18); and (IL) Unihex, Intra-Lock International (n = 18). Abutments were torqued to the implants, and maxillary central incisor crowns were cemented and subjected to step-stress-accelerated life testing in water. Use-level probability Weibull curves and probability of survival for a mission of 100,000 cycles at 200 N (95% 2-sided confidence intervals) were calculated. Stereo and scanning electron microscopes were used for failure inspection. The beta values for 3i, OL, and IL (1.60, 1.69, and 1.23, respectively) indicated that fatigue accelerated the failure of the 3 groups. Reliability for the 3i and OL (41% and 68%, respectively) was not different between each other, but both were significantly lower than IL group (98%). Abutment screw fracture was the failure mode consistently observed in all groups. Because the reliability was significantly different between the 3 groups, our postulated null hypothesis was rejected.

  7. Effect of core thickness differences on post-fatigue indentation fracture resistance of veneered zirconia crowns.

    PubMed

    Alhasanyah, Abdulrahman; Vaidyanathan, Tritala K; Flinton, Robert J

    2013-07-01

    Despite the excellent esthetics of veneered zirconia crowns, the incidence of chipping and fracture of veneer porcelain on zirconia crowns has been recognized to be higher than in metal ceramic crowns. The objective of this investigation was to study the effect of selected variations in core thickness on the post-fatigue fracture resistance of veneer porcelain on zirconia crowns. Zirconia crowns for veneering were prepared with three thickness designs of (a) uniform 0.6-mm thick core (group A), (b) extra-thick 1.7 mm occlusal core support (group B), and (c) uniform 1.2-mm thick core (group C). The copings were virtually designed and milled by the CAD/CAM technique. Metal ceramic copings (group D) with the same design as in group C were used as controls. A sample size of N = 20 was used for each group. The copings were veneered with compatible porcelain and fatigue tested under a sinusoidal loading regimen. Loading was done with a 200 N maximum force amplitude under Hertzian axial loading conditions at the center of the crowns using a spherical tungsten carbide indenter. After 100,000 fatigue cycles, the crowns were axially loaded to fracture and maximum load levels before fracture was recorded. One-way ANOVA (P < 0.05) and post hoc Tukey tests (α = 0.05) were used to determine significant differences between means. The mean fracture failure load of group B was not significantly different from that of control group D. In contrast, the mean failure loads of groups A and C were significantly lower than that of control group D. Failure patterns also indicated distinct differences in failure mode distributions. The results suggest that proper occlusal core support improves veneer chipping fracture resistance in zirconia crowns. Extra-thick occlusal core support for porcelain veneer may significantly reduce the veneer chipping and fracture of zirconia crowns. This is suggested as an important consideration in the design of copings for zirconia crowns. © 2013 by the American College of Prosthodontists.

  8. Descriptive statistics of tree crown condition in California, Oregon, and Washington

    Treesearch

    KaDonna C. Randolph; Sally J. Campbell; Glenn Christensen

    2010-01-01

    The U.S. Forest Service Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes four tree crown condition indicators (crown dieback, crown density, foliage transparency, and sapling crown vigor) measured in California, Oregon, and Washington between 1996 and 1999....

  9. Descriptive statistics of tree crown condition in the North Central United States

    Treesearch

    KaDonna C. Randolph; Randall S. Morin; Jim Steinman

    2010-01-01

    The U.S. Forest Service Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes four crown condition indicators (crown dieback, crown density, foliage transparency, and sapling crown vigor) measured in Illinois, Indiana, Michigan, Minnesota, Missouri, and Wisconsin...

  10. Descriptive statistics of tree crown condition in the United States Interior West

    Treesearch

    KaDonna C. Randolph; Mike T. Thompson

    2010-01-01

    The U.S. Forest Service Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes four crown condition indicators (crown dieback, crown density, foliage transparency, and sapling crown vigor) measured in Colorado, Idaho, Nevada, Utah, and Wyoming between 1996 and...

  11. Probability of survival of implant-supported metal ceramic and CAD/CAM resin nanoceramic crowns.

    PubMed

    Bonfante, Estevam A; Suzuki, Marcelo; Lorenzoni, Fábio C; Sena, Lídia A; Hirata, Ronaldo; Bonfante, Gerson; Coelho, Paulo G

    2015-08-01

    To evaluate the probability of survival and failure modes of implant-supported resin nanoceramic relative to metal-ceramic crowns. Resin nanoceramic molar crowns (LU) (Lava Ultimate, 3M ESPE, USA) were milled and metal-ceramic (MC) (Co-Cr alloy, Wirobond C+, Bego, USA) with identical anatomy were fabricated (n=21). The metal coping and a burnout-resin veneer were created by CAD/CAM, using an abutment (Stealth-abutment, Bicon LLC, USA) and a milled crown from the LU group as models for porcelain hot-pressing (GC-Initial IQ-Press, GC, USA). Crowns were cemented, the implants (n=42, Bicon) embedded in acrylic-resin for mechanical testing, and subjected to single-load to fracture (SLF, n=3 each) for determination of step-stress profiles for accelerated-life testing in water (n=18 each). Weibull curves (50,000 cycles at 200N, 90% CI) were plotted. Weibull modulus (m) and characteristic strength (η) were calculated and a contour plot used (m versus η) for determining differences between groups. Fractography was performed in SEM and polarized-light microscopy. SLF mean values were 1871N (±54.03) for MC and 1748N (±50.71) for LU. Beta values were 0.11 for MC and 0.49 for LU. Weibull modulus was 9.56 and η=1038.8N for LU, and m=4.57 and η=945.42N for MC (p>0.10). Probability of survival (50,000 and 100,000 cycles at 200 and 300N) was 100% for LU and 99% for MC. Failures were cohesive within LU. In MC crowns, porcelain veneer fractures frequently extended to the supporting metal coping. Probability of survival was not different between crown materials, but failure modes differed. In load bearing regions, similar reliability should be expected for metal ceramics, known as the gold standard, and resin nanoceramic crowns over implants. Failure modes involving porcelain veneer fracture and delamination in MC crowns are less likely to be successfully repaired compared to cohesive failures in resin nanoceramic material. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Hygroscopic expansion of self-adhesive resin cements and the integrity of all-ceramic crowns.

    PubMed

    Kirsten, Magdalena; Matta, Ragai Edward; Belli, Renan; Lohbauer, Ulrich; Wichmann, Manfred; Petschelt, Anselm; Zorzin, José

    2018-04-27

    Low pH neutralization and subsequent remnant hydrophilicity can lead to hygroscopic expansion of self-adhesive resin cements (SARCs) after water storage. The aim of this in vitro study was to investigate the effects of hygroscopic expansion of SARCs, used as luting and partial core build-up material, on integrity and cement gap thickness increase of all-ceramic CAD/CAM crowns. Human third molars (n=48) were prepared and anatomical all-ceramic CAD/CAM crowns were manufactured (VITABLOCS Mark II, VITA Zahnfabrik). Crowns internal surfaces were HF etched and silanized. The prepared teeth with their respective crowns were divided into 6 groups (n=8). In groups 1, 3 and 5 the coronal dentin was removed to simulate a partial core build-up. Groups 1 and 2 were luted with iCEM (Heraeus Kulzer), 3 and 4 with RelyX Unicem 2 Automix (3M), 5 and 6 with Variolink Esthetic DC (Ivoclar Vivadent). All specimens were dual cured and stored in distilled water at 37°C. Crown integrity was controlled at baseline and in regular intervals until 180 days. Cement gap thickness was measured using an optical 3D scanner (ATOS Triple scan, GOM) at baseline and after 180 days. Crown integrity was statistically analysed using Kaplan-Meier survival analysis and cement gap thickness increase using two-way ANOVA (α=0.05). After 180 days storage, crack formation was observed in all specimens of group 1 (mean survival time of 85.5 days), in one specimen of group 2 and in two specimens of group 4. Two-way ANOVA analysis revealed a statistically significant interaction between material type and build-up on cement gap size increase for iCEM. Within the limits of this study, the application of SARCs with low pH neutralization as partial build-up material under CAD/CAM crowns is not recommended for clinical use. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  13. Clinical Marginal and Internal Adaptation of Maxillary Anterior Single All-Ceramic Crowns and 2-year Randomized Controlled Clinical Trial.

    PubMed

    Akın, Aslı; Toksavul, Suna; Toman, Muhittin

    2015-07-01

    The aims of this randomized-controlled clinical trial were to compare marginal and internal adaptation of all-ceramic crowns fabricated with CAD/CAM and heat-pressed (HP) techniques before luting and to evaluate the clinical outcomes at baseline and at 6, 12, and 24 months after luting. Fifteen CAD/CAM (CC) and 15 HP all-ceramic crowns were placed in 15 patients. A silicone replica was obtained to measure marginal and internal adaptation of each all-ceramic crown before luting, and they were sectioned buccolingually and mesiodistally. Marginal and internal adaptations were measured using computerized light microscope at 40× magnification. Clinical evaluations took place at baseline (2 days after luting) and at 6, 12, and 24 months after luting. Replica scores were analyzed with Mann-Whitney U and Student's t-test (α = 0.05). Survival rate of crowns was determined using Kaplan-Meier statistical analysis. The median marginal gap for the CC group was 132.2 μm and was 130.2 μm for the HP group. The mean internal adaptation for the CC group was 220.3 ± 51.3 μm and 210.5 ± 31 μm for the HP group. There were no statistically significant differences with respect to marginal opening (Mann-Whitney U test; p = 0.95) and internal adaptation (Student's t-test; p = 0.535) between the 2 groups. Based on modified Ryge criteria, 100% of the crowns were rated satisfactory during the 2-year period. In this in vivo study, CAD/CAM and HP all-ceramic crowns exhibited similar marginal and internal adaptations. A 100% success rate was recorded for the 15 CAD/CAM and for the 15 HP all-ceramic crowns during the 2-year period. © 2014 by the American College of Prosthodontists.

  14. Randomized, Controlled Clinical Trial of Bilayer Ceramic and Metal-Ceramic Crown Performance

    PubMed Central

    Esquivel-Upshaw, Josephine; Rose, William; Oliveira, Erica; Yang, Mark; Clark, Arthur E.; Anusavice, Kenneth

    2013-01-01

    Purpose Analyzing the clinical performance of restorative materials is important, as there is an expectation that these materials and procedures will restore teeth and do no harm. The objective of this research study was to characterize the clinical performance of metal-ceramic crowns, core ceramic crowns, and core ceramic/veneer ceramic crowns based on 11 clinical criteria. Materials and Methods An IRB-approved, randomized, controlled clinical trial was conducted as a single-blind pilot study. The following three types of full crowns were fabricated: (1) metal-ceramic crown (MC) made from a Pd-Au-Ag-Sn-In alloy (Argedent 62) and a glass-ceramic veneer (IPS d.SIGN veneer); (2) non-veneered (glazed) lithium disilicate glass-ceramic crown (LDC) (IPS e.max Press core and e.max Ceram Glaze); and (3) veneered lithia disilicate glass-ceramic crown (LDC/V) with glass-ceramic veneer (IPS Empress 2 core and IPS Eris). Single-unit crowns were randomly assigned. Patients were recalled for each of 3 years and were evaluated by two calibrated clinicians. Thirty-six crowns were placed in 31 patients. A total of 12 crowns of each of the three crown types were studied. Eleven criteria were evaluated: tissue health, marginal integrity, secondary caries, proximal contact, anatomic contour, occlusion, surface texture, cracks/chips (fractures), color match, tooth sensitivity, and wear (of crowns and opposing enamel). Numerical rankings ranged from 1 to 4, with 4 being excellent, and 1 indicating a need for immediate replacement. Statistical analysis of the numerical rankings was performed using a Fisher’s exact test. Results There was no statistically significant difference between performance of the core ceramic crowns and the two veneered crowns at year 1 and year 2 (p > 0.05). All crowns were rated either as excellent or good for each of the clinical criteria; however, between years 2 and 3, gradual roughening of the occlusal surface occurred in some of the ceramic-ceramic crowns, possibly caused by dissolution and wear of the glaze. Statistically significant differences in surface texture (p = 0.0013) and crown wear (p = 0.0078) were found at year 3 between the metal-ceramic crowns and the lithium-disilicate-based crowns. Conclusion Based on the 11 criteria, the clinical performance of ceramic-ceramic crowns was comparable to that of the metal-ceramic crowns after 2 years; however, gradual roughening occurred between years 2 and 3, which resulted in differences in surface texture and wear. PMID:22978697

  15. Three-year clinical evaluation of two ceramic crown systems: a preliminary study.

    PubMed

    Etman, Maged K; Woolford, M J

    2010-02-01

    The clinical performance and failure mechanisms of recently introduced ceramic crown systems used to restore posterior teeth have not been adequately examined. The purpose of this prospective clinical study was to evaluate and compare the clinical performance of 2 new ceramic crown systems with that of metal ceramic crowns using modified United States Public Health Services (USPHS) criteria. Ninety posterior teeth requiring crown restorations in 48 patients were randomized into 3 equal groups (n=30) for which different crown systems were used: an experimental hot-pressed glass ceramic based on a modified lithium disilicate ceramic (IPS e.max Press), an alumina-coping-based ceramic (Procera AllCeram), and a metal ceramic (Simidur S 2 veneered with IPS Classic Porcelain). The crowns were assessed over 3 years using the modified USPHS criteria. Crowns that developed visible cracks were sectioned and removed, and the surfaces were analyzed using a scanning electron microscope (SEM). The data were analyzed using the Kruskal-Wallis nonparametric statistical test, followed by the Mann-Whitney test with Bonferroni correction (alpha=.05). USPHS evaluation showed that the IPS e.max Press and metal ceramic crowns experienced fewer clinical changes than Procera AllCeram. Visible roughness, wear, and deformity were noticed in occlusal contact areas of Procera AllCeram crowns. SEM images showed well defined wear facets in both ceramic crown systems. Kruskal-Wallis tests showed a significant difference (P<.05) in Alpha scores among the 3 crown systems. Mann-Whitney tests showed significant differences among groups. IPS e.max Press crowns demonstrated clinical behavior comparable to Procera AllCeram and metal ceramic crowns, but the wear resistance of this crown type was superior to the Procera AllCeram crowns, according to modified USPHS criteria.

  16. Preformed crowns for decayed primary molar teeth.

    PubMed

    Innes, Nicola P T; Ricketts, David; Chong, Lee Yee; Keightley, Alexander J; Lamont, Thomas; Santamaria, Ruth M

    2015-12-31

    Crowns for primary molars are preformed and come in a variety of sizes and materials to be placed over decayed or developmentally defective teeth. They can be made completely of stainless steel (know as 'preformed metal crowns' or PMCs), or to give better aesthetics, may be made of stainless steel with a white veneer cover or made wholly of a white ceramic material. In most cases, teeth are trimmed for the crowns to be fitted conventionally using a local anaesthetic. However, in the case of the Hall Technique, PMCs are pushed over the tooth with no local anaesthetic, carious tissue removal or tooth preparation. Crowns are recommended for restoring primary molar teeth that have had a pulp treatment, are very decayed or are badly broken down. However, few dental practitioners use them in clinical practice. This review updates the original review published in 2007. Primary objectiveTo evaluate the clinical effectiveness and safety of all types of preformed crowns for restoring primary teeth compared with conventional filling materials (such as amalgam, composite, glass ionomer, resin modified glass ionomer and compomers), other types of crowns or methods of crown placement, non-restorative caries treatment or no treatment. Secondary objectiveTo explore whether the extent of decay has an effect on the clinical outcome of primary teeth restored with all types of preformed crowns compared with those restored with conventional filling materials. We searched the following electronic databases: Cochrane Oral Health Group Trials Register (to 21 January 2015), Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library, 2014, Issue 12), MEDLINE via Ovid (1946 to 21 January 2015) and EMBASE via Ovid (1980 to 21 January 2015). We searched the US National Institutes of Health Trials Register (http://clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform for ongoing trials and Open Grey for grey literature (to 21 January 2015). No restrictions were placed on the language or date of publication when searching the databases. Randomised controlled trials (RCTs) that assessed the effectiveness of crowns compared with fillings, other types of crowns, non-restorative approaches or no treatment in children with untreated tooth decay in one or more primary molar teeth. We would also have included trials comparing different methods of fitting crowns.For trials to be considered for this review, the success or failure of the interventions and other clinical outcomes had to be reported at least six months after intervention (with the exception of 'pain/discomfort during treatment and immediately postoperatively'). Two review authors independently assessed the title and abstracts for each article from the search results. and independently assessed the full text for each potentially relevant study. At least two authors assessed risk of bias and extracted data using a piloted data extraction form. We included five studies that evaluated three comparisons. Four studies compared crowns with fillings; two of them compared conventional PMCs with open sandwich restorations, and two compared PMCs fitted using the Hall Technique with fillings. One of these studies included a third arm, which allowed the comparison of PMCs (fitted using the Hall Technique) versus non-restorative caries treatment. In the two studies using crowns fitted using the conventional method, all teeth had undergone pulpotomy prior to the crown being placed. The final study compared two different types of crowns: PMCs versus aesthetic stainless steel crowns with white veneers. No RCT evidence was found that compared different methods of fitting preformed metal crowns (i.e. Hall Technique versus conventional technique).We considered outcomes reported at the dental appointment or within 24 hours of it, and in the short term (less than 12 months) or long term (12 months or more). Some of our outcomes of interest were not measured in the studies: time to restoration failure or retreatment, patient satisfaction and costs. Crowns versus fillingsAll studies in this comparison used PMCs. One study reported outcomes in the short term and found no reports of major failure or pain in either group. There was moderate quality evidence that the risk of major failure was lower in the crowns group in the long term (risk ratio (RR) 0.18, 95% confidence interval (CI) 0.06 to 0.56; 346 teeth in three studies, one conventional and two using Hall Technique). Similarly, there was moderate quality evidence that the risk of pain was lower in the long term for the crown group (RR 0.15, 95% CI 0.04 to 0.67; 312 teeth in two studies).Discomfort associated with the procedure was lower for crowns fitted using the Hall Technique than for fillings (RR 0.56, 95% CI 0.36 to 0.87; 381 teeth) (moderate quality evidence).It is uncertain whether there is a clinically important difference in the risk of gingival bleeding when using crowns rather than fillings, either in the short term (RR 1.69, 95% CI 0.61 to 4.66; 226 teeth) or long term (RR 1.74, 95% CI 0.99 to 3.06; 195 teeth, two studies using PMCs with conventional technique at 12 months) (low quality evidence). Crowns versus non-restorative caries treatmentOnly one study compared PMCs (fitted with the Hall Technique) with non-restorative caries treatment; the evidence quality was very low and we are therefore we are uncertain about the estimates. Metal crowns versus aesthetic crownsOne split-mouth study (11 participants) compared PMCs versus aesthetic crowns (stainless steel with white veneers). It provided very low quality evidence so no conclusions could be drawn. Crowns placed on primary molar teeth with carious lesions, or following pulp treatment, are likely to reduce the risk of major failure or pain in the long term compared to fillings. Crowns fitted using the Hall Technique may reduce discomfort at the time of treatment compared to fillings. The amount and quality of evidence for crowns compared to non-restorative caries, and for metal compared with aesthetic crowns, is very low. There are no RCTs comparing crowns fitted conventionally versus using the Hall Technique.

  17. Assessing crown fire potential by linking models of surface and crown fire behavior

    Treesearch

    Joe H. Scott; Elizabeth D. Reinhardt

    2001-01-01

    Fire managers are increasingly concerned about the threat of crown fires, yet only now are quantitative methods for assessing crown fire hazard being developed. Links among existing mathematical models of fire behavior are used to develop two indices of crown fire hazard-the Torching Index and Crowning Index. These indices can be used to ordinate different forest...

  18. Removal of failed crown and bridge

    PubMed Central

    Rahul, G R.; Poduval, Soorya T.; Shetty, Karunakar

    2012-01-01

    Crown and bridge have life span of many years but they fail for a number of reasons. Over the years, many devices have been designed to remove crowns and bridges from abutment teeth. While the removal of temporary crowns and bridges is usually very straightforward, the removal of a definitive cast crown with unknown cement is more challenging. Removal is often by destructive means. There are a number of circumstances, however, in which conservative disassembly would aid the practitioner in completing restorative/endodontic procedures. There are different mechanisms available to remove a failed crown or bridge. But there is no information published about the classification of available systems for crown and bridge removal. So it is logical to classify these systems into different groups which can help a clinician in choosing a particular type of system depending upon the clinical situation. The aim of this article is to provide a classification for various crown and bridge removal systems; describe how a number of systems work; and when and why they might be used. A PubMed search of English literature was conducted up to January 2010 using the terms: Crown and bridge removal, Crown and bridge disassembly, Crown and bridge failure. Additionally, the bibliographies of 3 previous reviews, their cross references as well as articles published in various journals like International Endodontic Journal, Journal of Endodontics and were manually searched. Key words:Crown and bridge removal, Crown and bridge disassembly, Crown and bridge failure. PMID:24558549

  19. Pulpotomy to stainless steel crown ratio in children with early childhood caries: a cross-sectional analysis.

    PubMed

    Thikkurissy, Sarat; McTigue, Dennis; Matracia, Sophie; Casamassimo, Paul

    2011-01-01

    This study's purpose was to determine the pulpotomy-to-crown ratio (PCR) in a high-early childhood caries patient population and factors associated with choice of pulpotomy and crown treatments. This was a retrospective quality assurance chart review. Five calibrated examiners (kappa=0.86) rated radiographic caries from available films. Demographic data, including age, health status, medications, and pain score, were collected along with pulpotomy- and crown-related treatment characteristics of location of tooth, treatment site, and level of operator skill. The record review of 521 patients (mean age=5.1 ± 1.9 years old) revealed 1,365 stainless steel crowns (SSCs) performed with 461 pulpotomies in a 6-month period, in both operating rooms (1,043 SSCs) and ambulatory settings (322 SSCs). The mean PCR was 0.34, with PCR decreasing with increasing patient age. Pulpotomy and crown treatments increased with radiographic caries severity with a significant association between pulpotomy and radiographic severity (P<.001). More severe pain was associated with greater likelihood of pulpotomy (P<.001). Age, operator type, and site of treatment did not affect choice of pulpotomy. The mean pulpotomy-to-crown ratio in this high-early childhood caries pediatric population was 0.34. Pain, the American Society of Anesthesiologists classification system, and radiographic caries severity were predictors of pulpotomy, but operator type and location of treatment were not.

  20. Preparation and Structural Properties of InIII–H Complexes

    PubMed Central

    Sickerman, Nathaniel S.; Henry, Renée M.; Ziller, Joseph W.

    2013-01-01

    The use of the tripodal ligands tris[(N'-tert-butylureaylato)-N-ethyl]aminato ([H3buea]3−) and the sulfonamide-based N,N',N"-[2,2',2"-nitrilotris(ethane-2,1-diyl)]tris(2,4,6-trimethylbenzene-sulfonamidato) ([MST]3−) has led to the synthesis of two structurally distinct In(III)–OH complexes. The first example of a five-coordinate indium(III) complex with a terminal hydroxide ligand, K[InIIIH3buea(OH)], was prepared by addition of In(OAc)3 and water to a deprotonated solution of H6buea. X-ray diffraction analysis, as well as FTIR and 1H NMR spectroscopic methods, provided evidence for the formation of a monomeric In(III)–OH complex. The complex contains an intramolecular hydrogen bonding (H-bonding) network involving the In(III)–OH unit and [H3buea]3− ligand, which aided in isolation of the complex. Isotope labeling studies verified the source of the hydroxo ligand as water. Treatment of the [InIIIMST] complex with a mixture of 15-crown-5 ether and NaOH led to isolation of the complex [15-crown-5⊃NaI-(μ-OH)-InIIIMST], whose solid-state structure was confirmed using X-ray diffraction methods. Nuclear magnetic resonance studies on this complex suggest it retains its heterobimetallic structure in solution. PMID:25309019

  1. [Survival rate of IPS-Empress 2 all-ceramic crowns and bridges: three year's results].

    PubMed

    Zimmer, Doris; Gerds, Thomas; Strub, Jörg R

    2004-01-01

    The objective of this prospective clinical study was to calculate the survival rate of IPS-Empress2 crowns and fixed partial dentures (FPD) over a three-year period. In 43 patients 27 IPS-Empress2 crowns and 31 fixed partial dentures were adhesively luted. Crowns were placed on premolars and molars and FPDs were inserted in the anterior and premolar area. Abutments were prepared with a circular 1.2 mm wide shoulder. The clinical follow-up examination took place after 6, 12, 24, 36 and 48 months. After a mean of 38 months, the survival rate (Kaplan-Meier) of all-ceramic crowns was 100% and of the three unit FDP 72.4%. There were a total of six complete failures which occurred only with the three-unit IPS-Empress2 FPDs. Three FPDs exhibited fractures of the framework for which the manufacturer's instructions of connector-dimension was not satisfied, and one FPD exhibited an irreparable incomplete veneer fracture. Further two FPDs showed biological failures. The accuracy of fit and esthetics were clinically satisfactory. The three-year results showed the IPS-Empress2-ceramic as an adequate all-ceramic material for single crowns. The use for FPD needs further critical consideration.

  2. A method of evaluating crown fuels in forest stands.

    Treesearch

    Rodney W. Sando; Charles H. Wick

    1972-01-01

    A method of describing the crown fuels in a forest fuel complex based on crown weight and crown volume was developed. A computer program is an integral part of the method. Crown weight data are presented in graphical form and are separated into hardwood and coniferous fuels. The fuel complex is described using total crown weight per acre, mean height to the base of...

  3. Equations to convert compacted crown ratio to uncompacted crown ratio for trees in the Interior West

    Treesearch

    Chris Toney; Matthew C. Reeves

    2009-01-01

    Crown ratio is the proportion of total tree length supporting live foliage. Inventory programs of the US Forest Service generally define crown ratio in terms of compacted or uncompacted measurements. Measurement of compacted crown ratio (CCR) involves envisioning the transfer of lower branches of trees with asymmetric crowns to fill holes in the upper portion of the...

  4. Relation of Crown Width to Tree Diameter In Some Upland Hardwood Stands of Southern Illinois

    Treesearch

    Leon S. Minckler; Samuel F. Gingrich

    1970-01-01

    Crown width-d.b.h. relationships in well stocked, uneven-aged stands of oak and hickory were similar to those for open-grown trees and were independent of site, crown class, and species. The irregular crowns of forest grown trees interface and overlap, however, and measuring crown extensions to the branch tips tended to overestimate effective crown area

  5. Modeling the spatial distribution of forest crown biomass and effects on fire behavior with FUEL3D and WFDS

    Treesearch

    Russell A. Parsons; William Mell; Peter McCauley

    2010-01-01

    Crown fire poses challenges to fire managers and can endanger fire fighters. Understanding of how fire interacts with tree crowns is essential to informed decisions about crown fire. Current operational crown fire predictions in the United States assume homogeneous crown fuels. While a new class of research fire models, which model fire behavior with computational...

  6. Comparative evaluation of marginal leakage of provisional crowns cemented with different temporary luting cements: In vitro study.

    PubMed

    Arora, Sheen Juneja; Arora, Aman; Upadhyaya, Viram; Jain, Shilpi

    2016-01-01

    As, the longevity of provisional restorations is related to, a perfect adaptation and a strong, long-term union between restoration and teeth structures, therefore, evaluation of marginal leakage of provisional restorative materials luted with cements using the standardized procedures is essential. To compare the marginal leakage of the provisional crowns fabricated from Autopolymerizing acrylic resin crowns and bisphenol A-glycidyl dimethacrylate (BIS-GMA) resin crowns. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin crowns and BIS-GMA resin crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin (SC-10) crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from BIS-GMA resin crowns (Protemp 4) cemented with different temporary luting cements. Freshly extracted 60 maxillary premolars of approximately similar dimensions were mounted in dental plaster. Tooth reduction with shoulder margin was planned to use a customized handpiece-holding jig. Provisional crowns were prepared using the wax pattern fabricated from computer aided designing/computer aided manufacturing milling machine following the tooth preparation. Sixty provisional crowns were made, thirty each of SC-10 and Protemp 4 and were then cemented with three different luting cements. Specimens were thermocycled, submerged in a 2% methylene blue solution, then sectioned and observed under a stereomicroscope for the evaluation of marginal microleakage. A five-level scale was used to score dye penetration in the tooth/cement interface and the results of this study was analyzed using the Chi-square test, Mann-Whitney U-test, Kruskal-Wallis H-test and the results were statistically significant P < 0.05 the power of study - 80%. Marginal leakage was significant in both provisional crowns cemented with three different luting cements along the axial walls of teeth (P < 0.05) confidence interval - 95%. The temporary cements with eugenol showed more microleakage than those without eugenol. SC-10 crowns showed more microleakage compared to Protemp 4 crowns. SC-10 crowns cemented with Kalzinol showed maximum microleakage and Protemp 4 crowns cemented with HY bond showed least microleakage.

  7. Structure and reactivity of boron-ate complexes derived from primary and secondary boronic esters.

    PubMed

    Feeney, Kathryn; Berionni, Guillaume; Mayr, Herbert; Aggarwal, Varinder K

    2015-06-05

    Boron-ate complexes derived from primary and secondary boronic esters and aryllithiums have been isolated, and the kinetics of their reactions with carbenium ions studied. The second-order rate constants have been used to derive nucleophilicity parameters for the boron-ate complexes, revealing that nucleophilicity increased with (i) electron-donating aromatics on boron, (ii) neopentyl glycol over pinacol boronic esters, and (iii) 12-crown-4 ether.

  8. Electron-donor dopant, method of improving conductivity of polymers by doping therewith, and a polymer so treated

    DOEpatents

    Liepins, R.; Aldissi, M.

    1984-07-27

    Polymers with conjugated backbones, both polyacetylene and polyaromatic heterocyclic types, are doped with electron-donor agents to increase their electrical conductivity. The electron-donor agents are either electride dopants made in the presence of lithium or dopants derived from alkalides made in the presence of lithium. The dopants also contain a metal such as cesium and a trapping agent such as a crown ether.

  9. Electron-donor dopant, method of improving conductivity of polymers by doping therewith, and a polymer so treated

    DOEpatents

    Liepins, Raimond; Aldissi, Mahmoud

    1988-01-01

    Polymers with conjugated backbones, both polyacetylene and polyaromatic heterocyclic types, are doped with electron-donor agents to increase their electrical conductivity. The electron-donor agents are either electride dopants made in the presence of lithium or dopants derived from alkalides made in the presence of lithium. The dopants also contain a metal such as cesium and a trapping agent such as a crown ether.

  10. The Crown Ether Promoted Base Degradation of p-Carborane.

    DTIC Science & Technology

    1982-04-20

    soluble in methylene chloride, benzene, ethanol and tetrahydrofuran. The cation may be exchanged by a two-phase acidification procedure in which the [K...472 Attn: CRD-AA-IP 800 North Quincy Street P.O. Box 1211 Arlington, Virginia 22217 2 Research Triangle Park, N.C. 27709 ONR Branch Office Naval Ocean ...21401 Washington, D.C. 20360 1 Naval Ocean Systems Center Defense Documentation Center Attn: Dr. S. Yamamoto, Marine Building 5, Cameron Station Sciences

  11. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E.P.; Dietz, M.L.

    1994-09-13

    A method and apparatus are disclosed for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water. 1 fig.

  12. Calix[3]carbazole: A C3-symmetrical receptor for barium ion

    NASA Astrophysics Data System (ADS)

    Yang, Zhaozheng; Tian, Zhangmin; Yang, Peng; Deng, Tuo; Li, Gang; Zhou, Xue; Chen, Yan; Zhao, Liang; Shen, Hongyan

    2017-03-01

    The binding ability of calix[3]carbazole (1) to metal ions has been investigated. It is found that 1 could serve as a non crown ether based, C3-symmetrical receptor for Ba2 + via the marriage of cation-π and cation-dipole interactions. FID assay further illustrates that 1 could selectively interact with Ba2 + over Pd2 +. A possible binding mechanism for [1-Ba2 +] complex is proposed.

  13. Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown.

    PubMed

    Ji, Min-Kyung; Park, Ji-Hee; Park, Sang-Won; Yun, Kwi-Dug; Oh, Gye-Jeong; Lim, Hyun-Pil

    2015-08-01

    This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau®Zirconia and ZENOSTAR®ZR translucent) and lithium disilicate glass ceramic (IPS e.max®press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max®press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). The lithium disilicate glass ceramic crown (IPS e.max®press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR®ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max®press) had overextended margins.

  14. In-vitro performance and fracture strength of thin monolithic zirconia crowns

    PubMed Central

    Weigl, Paul; Wu, Yanyun; Felber, Roland; Lauer, Hans-Christoph

    2018-01-01

    PURPOSE All-ceramic restorations required extensive tooth preparation. The purpose of this in vitro study was to investigate a minimally invasive preparation and thickness of monolithic zirconia crowns, which would provide sufficient mechanical endurance and strength. MATERIALS AND METHODS Crowns with thickness of 0.2 mm (group 0.2, n=32) or of 0.5 mm (group 0.5, n=32) were milled from zirconia and fixed with resin-based adhesives (groups 0.2A, 0.5A) or zinc phosphate cements (groups 0.2C, 0.5C). Half of the samples in each subgroup (n=8) underwent thermal cycling and mechanical loading (TCML)(TC: 5℃ and 55℃, 2×3,000 cycles, 2 min/cycle; ML: 50 N, 1.2×106 cycles), while the other samples were stored in water (37℃/24 h). Survival rates were compared (Kaplan-Maier). The specimens surviving TCML were loaded to fracture and the maximal fracture force was determined (ANOVA; Bonferroni; α=.05). The fracture mode was analyzed. RESULTS In both 0.5 groups, all crowns survived TCML, and the comparison of fracture strength among crowns with and without TCML showed no significant difference (P=.628). Four crowns in group 0.2A and all of the crowns in group 0.2C failed during TCML. The fracture strength after 24 hours of the cemented 0.2 mm-thick crowns was significantly lower than that of adhesive bonded crowns. All cemented crowns provided fracture in the crown, while about 80% of the adhesively bonded crowns fractured through crown and die. CONCLUSION 0.5 mm thick monolithic crowns possessed sufficient strength to endure physiologic performance, regardless of the type of cementation. Fracture strength of the 0.2 mm cemented crowns was too low for clinical application. PMID:29713427

  15. Coordination of crown structure, leaf plasticity and carbon gain within the crowns of three winter-deciduous mature trees.

    PubMed

    Uemura, Akira; Harayama, Hisanori; Koike, Nobuya; Ishida, Atsushi

    2006-05-01

    We examined the vertical profiles of leaf characteristics within the crowns of two late-successional (Fagus crenata Blume and Fagus japonica Maxim.) and one early-successional tree species (Betula grossa Sieb. et Zucc.) in a Japanese forest. We also assessed the contributions of the leaves in each crown layer to whole-crown instantaneous carbon gain at midday. Carbon gain was estimated from the relationship between electron transport and photosynthetic rates. We hypothesized that more irradiance can penetrate into the middle of the crown if the upper crown layers have steep leaf inclination angles. We found that such a crown has a high whole-crown carbon gain, even if leaf traits do not change greatly with decreasing crown height. Leaf area indices (LAIs) of the two Fagus trees (5.26-5.52) were higher than the LAI of the B. grossa tree (4.50) and the leaves of the F. crenata tree were more concentrated in the top crown layers than were leaves of the other trees. Whole-crown carbon gain per unit ground area (micromol m(-2) ground s(-1)) at midday on fine days in summer was 16.3 for F. crenata, 11.0 for F. japonica, and 20.4 for B. grossa. In all study trees, leaf dry mass (LMA) and leaf nitrogen content (N) per unit area decreased with decreasing height in the crown, but leaf N per unit mass increased. Variations (plasticity) between the uppermost and lowermost crown layers in LMA, leaf N, the ratio of chlorophyll to N and the ratio of chlorophyll a to b were smaller for F. japonica and B. grossa than for F. crenata. The light extinction coefficients in the crowns were lower for the F. japonica and B. grossa trees than for the F. crenata tree. The leaf carbon isotope ratio (delta(13)C) was higher for F. japonica and B. grossa than for F. crenata, especially in the mid-crown. These results suggest that, in crowns with low leaf plasticity but steep leaf inclination angles, such as those of F. japonica and B. grossa trees, irradiance can penetrate into the middle of the crowns, thereby enhancing whole-crown carbon gain.

  16. Twenty-nine-month follow-up of a paediatric zirconia dental crown.

    PubMed

    Lopez Cazaux, Serena; Hyon, Isabelle; Prud'homme, Tony; Dajean Trutaud, Sylvie

    2017-06-14

    The aim of this paper is to present the long-term follow-up of one paediatric zirconia crown on a deciduous molar. Preformed crowns are part of the armamentarium in paediatric dentistry. In recent years, aesthetic alternatives to preformed metal crowns have been developed, first preveneered crowns and then zirconia crowns. This paper describes the restoration of a primary molar with a zirconia crown (EZ-Pedo, Loomis, California, USA) in an 8-year-old boy. In this clinical case, the protocol for the implementation and maintenance of zirconia crowns is detailed. The patient was followed up for 29 months until the natural exfoliation of his primary molar. The adaptation of the zirconia crown, the gingival health and the wear on the opposing tooth were considered. In this case, the paediatric zirconia crown allowed sustainable functional restoration while restoring a natural appearance of the tooth. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. An investigation of crown fuel bulk density effects on the dynamics of crown fire initiation in shrublands

    Treesearch

    Watcharapong Tachajapong; Jesse Lozano; Shankar Mahalingam; Xiangyang Zhou; David R. Weise

    2008-01-01

    Crown fire initiation is studied by using a simple experimental and detailed physical modeling based on Large Eddy Simulation (LES). Experiments conducted thus far reveal that crown fuel ignition via surface fire occurs when the crown base is within the continuous flame region and does not occur when the crown base is located in the hot plume gas region of the surface...

  18. The role of an occlusal template during the placement of preformed metal crowns in children under general anaesthesia: a randomised control trial.

    PubMed

    Pani, S C; Dimashkieh, M; Mojaleed, F; Al Shammery, F

    2015-12-01

    This aim was to evaluate preformed metal crowns (PMC) placed under general anaesthesia using an occlusal template in comparison to crowns placed without the use of a template. CONSORT protocols were followed in the design of the study. A total of 60 children between 4-7 years requiring pulpotomy and PMC for all primary molars met the inclusion criteria for this study. The control group comprised patients for whom the PMC were placed without the use of an occlusal template, while in the test group crowns were placed using a polyvinyl siloxane occlusal template. Patients were followed up at 24 h, 7 days, 3 and 6 months. The time taken for the placement of crowns, instances of post-operative discomfort, success or failure of the pulp therapy and loss of any crowns were compared between the groups. The mean time taken for completion of the procedure in the control group was significantly greater than the template group (t = 2.566, p = 0.013). Significantly fewer patients in the template group reported symptoms of discomfort or high points at the 24-h recall; however, these differences were not significant at the 1-week, 3- or 6-month recall. The use of an occlusal template for the placement of multiple PMC under general anaesthesia reduces the time taken for their placement and reduces the incidence of immediate post-operative discomfort.

  19. Molar crown and root size relationship in anthropoid primates.

    PubMed

    Kupczik, Kornelius; Olejniczak, Anthony J; Skinner, Matthew M; Hublin, Jean-Jacques

    2009-01-01

    Mandibular corpus form is thought to reflect masticatory function and the size of the dentition, but there is no universal association between crown dimensions and corpus size across anthropoids. Previous research was based on the assumption that crown size is an appropriate proxy for overall tooth size, but this hypothesis remains largely untested. This study assesses the relationship between the volume and surface area of molar crowns and roots by examining two main hypotheses: (1) crown size correlates significantly with root size, and (2) the proportion of root-to-crown surface area is related to dietary proclivity. Permanent M2s (n=58) representing 19 anthropoid species were CT scanned and the volume and surface area of the crown and root were measured. Interspecific correlation and regression analyses reveal significant isometric relationships between crown and root volume and a positive allometric relationship between root and crown surface area (i.e. as crown surface area increases, root surface area becomes disproportionately greater). Intraspecifically, crown and root surface area correlate significantly in some species where such analyses were possible. In general, hard object feeders exhibit relatively larger root surface area per unit crown surface area compared to soft and tough object feeders. The results also show that despite differences in food specialization closely related species have similar root-to-crown surface area proportions, thus indicating a strong phylogenetic influence. Since it is possible that, at least in some species, crown and root size vary independently, future studies should elucidate the relationship between tooth root size and mandible form. Copyright (c) 2009 S. Karger AG, Basel.

  20. Short-Term Prospective Clinical Evaluation of Monolithic and Partially Veneered Zirconia Single Crowns.

    PubMed

    Bömicke, Wolfgang; Rammelsberg, Peter; Stober, Thomas; Schmitter, Marc

    2017-02-01

    The purpose of this study was to prospectively evaluate the short-term clinical performance and esthetics of monolithic and partially (i.e., facially) veneered zirconia single crowns (MZC and PZC, respectively). Between September 2011 and June 2013, 68 participants received 90 MZCs and 72 PZCs. Clinical study documentation was performed at crown cementation (baseline), at the 6-month follow-up, and then yearly thereafter using standardized report forms. Eight participants with 14 single crowns (eight MZCs and six PZCs) dropped out during clinical follow-up. Thus, 60 participants (28 male, mean age 62.5 ± 13.1 years) fitted with 82 MZCs and 66 PZCs were analyzed in February 2016 (Kaplan-Meier survival; mean observation time for the restorations 35.1 ± 6.3 months). Descriptive statistics were calculated for participants' and dentists' esthetic ratings on a numerical rating scale from 0 to 10 (0 = unacceptable color and shape; 10 = excellent color and shape). Complications were predominantly biological in nature. One PZC was affected by minor chipping. Cumulative 3-year failure-free survival was 98.5% (standard error (SE), 1.5%) for both MZCs and PZCs. Three-year cumulative complication-free survival (success) was 93.6% (SE 2.8%) for MZCs and 95.5% (SE 2.6%) for PZCs. Three-year cumulative fracture-free survival was 100% for MZCs and 98.5% (SE 1.5%) for PZCs. Crowns of both types were awarded high esthetic scores by participants and dentists. Monolithic and partially veneered zirconia crowns can be used clinically with excellent short-term survival and success and without compromising esthetic appearance. Longer-term follow-up is, however, desirable. During the observation time, both monolithic and partially veneered zirconia crowns showed an outstanding low technical complication rate: only one minor chipping and three losses of retention were observed. Additionally, esthetics was excellent. Based on these results the clinical use of this kind of restoration is promising. (J Esthet Restor Dent 29:22-30, 2017). © 2016 Wiley Periodicals, Inc.

  1. Crown Condition

    Treesearch

    KaDonna C. Randolph

    2009-01-01

    Photosynthetic capacity is dependent upon the size and condition of the tree crown. Trees with full, vigorous crowns are generally associated with more vigorous growth rates (Zarnoch and others 2004). Therefore, the Forest Service Forest Inventory and Analysis (FIA) Program measures a suite of crown condition indicators to evaluate forest health. Among the crown...

  2. Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol.

    PubMed

    Dahl, Bjørn Einar; Rønold, Hans Jacob; Dahl, Jon E

    2017-03-01

    Whether single crowns produced by computer-aided design and computer-aided manufacturing (CAD-CAM) have an internal fit comparable to crowns made by lost-wax metal casting technique is unknown. The purpose of this in vitro study was to compare the internal fit of single crowns produced with the lost-wax and metal casting technique with that of single crowns produced with the CAD-CAM technique. The internal fit of 5 groups of single crowns produced with the CAD-CAM technique was compared with that of single crowns produced in cobalt-chromium with the conventional lost-wax and metal casting technique. Comparison was performed using the triple-scan protocol; scans of the master model, the crown on the master model, and the intaglio of the crown were superimposed and analyzed with computer software. The 5 groups were milled presintered zirconia, milled hot isostatic pressed zirconia, milled lithium disilicate, milled cobalt-chromium, and laser-sintered cobalt-chromium. The cement space in both the mesiodistal and buccopalatal directions was statistically smaller (P<.05) for crowns made by the conventional lost-wax and metal casting technique compared with that of crowns produced by the CAD-CAM technique. Single crowns made using the conventional lost-wax and metal casting technique have better internal fit than crowns produced using the CAD-CAM technique. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Subjective Differences between Dentists and Patients about Relative Quality of Metal Ceramic Restorations placed in the Esthetic Zone.

    PubMed

    Al Moaleem, Mohammed M; Alkhayrat, Faisal M; Madkhali, Hussam A; Geathy, Ibrahim H; Qahhar, Mohammed Aw; Yaqoub, Ahmed; Mattoo, Khurshid A

    2017-02-01

    Esthetic perceptions could differ between the dentist and his patients among various regions and cultures. The aims of this study were to evaluate the subjective differences between the dentist and the patient in terms of esthetics of metal-ceramic crowns (MCcs). The study also aims to compare the mesiodistal (MD) and buccolingual (BL) dimensions of the cemented crown with its respective natural antimeric tooth. A total of 85 patients seeking treatment for a single crown (MC) were treated by the undergraduate students under supervision of respective academic staff. After cementation of the crowns, a 9-point questionnaire was given to patient and different dentists. A treatment cast for every single crown was poured. Then, the MD and BL dimensions of the crowns were compared against their respective antimeric tooth. The dentists and the patients agreed in the range of 50.5 to 90.5%. Least subjective differences were found for the length and width of the cemented crowns. The highest differences were noted for symmetry between the cemented crown and its antimeric natural tooth. A total of 31 to 38% of the patients differed from the dentist's evaluation for shade of the crown, color of the crown at the margin, contour of the crown, and the relationship of the crowns with the surrounding gingiva. The highest MD and BL dimensions were in the cemented crown of canines, while the lowest MD and BL diameters were for the cemented crowns of the lateral incisor crowns. Dentist and patient mostly agreed in terms of length (90%), width (81%) and relation of crown with free gingiva (74%). However, they differed mostly on the symmetry of the cemented crowns. The highest MD dimensions and BL diameter were in the cemented MCcs of canine, while the lowest were with lateral incisors. While fabricating a dental prosthesis, the dentist must know about patients' perception of esthetics; otherwise both clinical and laboratory efforts would not be enough to satisfy the esthetic needs of the patient even if the restoration is technically correct. Perceptions related to symmetry differ mostly between dentist and patient.

  4. Single-crystal-to-single-crystal transformation and solvochromic luminescence of a dinuclear gold(I)-(aza-[18]crown-6)dithiocarbamate compound.

    PubMed

    Tzeng, Biing-Chiau; Chao, An

    2015-01-26

    The treatment of [AuCl(SMe2 )] with an equimolar amount of NaO5 NCS2 (O5 NCS2 =(aza-[18]crown-6)dithiocarbamate) in CH3 CN gave [Au2 (O5 NCS2 )2 ]⋅2 CH3 CN (2⋅2 CH3 CN), and its crystal structure displays a dinuclear gold(I)-azacrown ether ring and an intermolecular gold(I)⋅⋅⋅gold(I) contact of 2.8355(3) Å in crystal lattices. It is noted that two other single crystals of 2⋅tert-butylbenzene⋅H2 O and 2⋅0.5 m-xylene can be successfully obtained from a single-crystal-to-single-crystal (SCSC) transformation process by immersing single crystals of 2⋅2 CH3 CN in the respective solvents, and both also show intermolecular gold(I)⋅⋅⋅gold(I) contacts of 2.9420(5) and 2.890(2)-2.902(2) Å, respectively. Significantly, the emissions of all three 2⋅solvates are well correlated with their respective intermolecular gold(I)⋅⋅⋅gold(I) contacts, where such contacts increase with 2⋅2 CH3 CN (2.8355(3) Å)<2⋅0.5 m-xylene (2.890(2)-2.902(2) Å)<2⋅tert-butylbenzene⋅H2 O (2.9420(5) Å), and their emission energies increase with 2⋅2 CH3 CN (602 nm)<2⋅0.5 m-xylene (583 nm)<2⋅tert-butylbenzene⋅H2 O (546 nm) as well. In this regard, we further examine the solvochromic luminescence for some other aromatics, and finally their emissions are within 546-602 nm. Obviously, the above results are mostly ascribed to the occurrence of intermolecular gold(I)⋅⋅⋅gold(I) contacts in 2⋅solvates, which are induced by the presence of various solvates in the solid state, as a key role to be responsible for their solvochromic luminescence. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Evaluation of Mechanical Properties and Marginal Fit of Crowns Fabricated Using Commercially Pure Titanium and FUS-Invest

    PubMed Central

    Wu, Jinshuang; Wang, Xianli; Xing, Helin; Guo, Tianwen; Dong, Chaofang

    2017-01-01

    This study investigated the mechanical properties and single crown accuracy of the tailor-made Fourth University Stomatology investment (FUS-invest) for casting titanium. Background. Current investment for casting titanium is not optimal for obtaining high-quality castings, and the commercially available titanium investment is costly. Methods. Titanium specimens were cast using the tailor-made FUS-invest. The mechanical properties were tested using a universal testing machine. Fractured castings were characterized by energy-dispersive spectroscopy. 19 titanium crowns were produced using FUS-invest and another 19 by Symbion. The accuracy of crowns was evaluated. Results. The mechanical properties of the titanium cast by FUS-invest were elastic modulus 125.6 ± 8.8 GPa, yield strength 567.5 ± 11.1 MPa, tensile strength 671.2 ± 15.6 MPa, and elongation 4.6 ± 0.2%. For marginal fit, no significant difference (P > 0.05) was found at four marker points of each group. For internal fit, no significant difference (P > 0.05) was found between two groups, whereas significant difference (P < 0.01) was found at different mark point of each group. Conclusions. The mechanical properties of titanium casted using FUS-invest fulfilled the ISO 9693 criteria. The marginal and internal fit of the titanium crowns using either the FUS-invest or Symbion were similar. PMID:28913355

  6. Randomized trial investigating zirconia electroplated telescopic retainers: quality of life outcomes.

    PubMed

    Schwindling, Franz Sebastian; Deisenhofer, Ulrich Karl; Séché, Anne-Christiane; Lehmann, Franziska; Rammelsberg, Peter; Stober, Thomas

    2017-05-01

    The study aims to evaluate the effect of electroplated telescopic removable dental prostheses (E-RDPs) with zirconia primary crowns on oral-health-related quality of life (OHRQoL). For E-RDPs, electroplating is used to produce precisely fitting gold copings on telescopic primary crowns. These copings are bonded intra-orally to the denture framework. Fifty-six participants in need of 60 removable restorations were randomly allocated one of two materials for the primary crowns: cobalt-chromium alloy or zirconia. OHRQoL was assessed by use of the 49-item Oral Health Impact Profile (OHIP-49) and by additional patient self-rating at baseline before treatment, and after 6 and 12 months. Statistical analysis was performed by use of one- and two-sample t-tests and analysis of covariance. Mean OHIP sum score at baseline was 53.4 (SD 37.4, 95 % CI 41.3-62). At follow-ups, it decreased significantly (after 6 months: mean 20, SD 26, 95 % CI 13-27.1; after 12 months: mean 16.4, SD 17.9, 95 % CI 11.6-21.2). The mean reduction in OHIP sum score after 12 months was 25 (SD 31.2, 95 % CI 13.1-36.9) for cobalt-chromium alloy and 44.4 (SD 32.3, 95 % CI 31.1-57.8) for zirconia. However, no statistically significant difference of the two materials on OHIP change or patient self-rating was detected. Although OHRQoL was improved by using both cobalt-chromium alloy and zirconia primary crowns for E-RDPs, post-treatment differences between the groups were not statistically significant. Zirconia E-RDPs enhance OHRQoL. However, zirconia primary crowns do not outperform cobalt-chromium alloy crowns regarding patient satisfaction-despite their tooth-like color.

  7. Single crowns in the resorbed posterior maxilla supported by either 6-mm implants or by 11-mm implants combined with sinus floor elevation surgery: a 1-year randomised controlled trial.

    PubMed

    Guljé, Felix L; Raghoebar, Gerry M; Vissink, Arjan; Meijer, Henny J A

    2014-01-01

    The aim of this randomised controlled trial was to assess the clinical performance of single crowns in the posterior maxilla supported by either 6-mm or 11-mm implants combined with maxillary sinus floor elevation. 41 consecutive patients with one missing premolar or molar in the posterior maxilla and with an estimated bone height of 6 to 8 mm in that area were included. Each patient was randomly allocated to one of the two treatment groups, namely to receive an 11-mm implant (Osseo Speed 4.0 S, Dentsply Implants, Mölndal, Sweden) in combination with maxillary sinus floor elevation surgery or to receive a 6-mm implant (Osseo Speed 4.0 S) without any grafting. After a 3-month osseointegration period, all implants were restored with custom-made titanium abutments and cemented zirconia-based porcelain crowns. Outcome measures were: implant survival; radiographic bone changes; plaque accumulation; bleeding tendency; peri-implant inflammation; presence of dental calculus; biological and technical complications; and patients' satisfaction. Clinical and radiographic examinations were performed at placement of the crown and 12 months thereafter. Patients' satisfaction was scored before treatment and after 12 months of functioning of the crown. One patient of the 11 mm implant group died during the follow-up. No implant failed and no biological or technical complications occurred. From loading to the 12 months follow-up, no difference was found in mean marginal bone changes between the groups (bone resorption in both groups 0.1 ± 0.3 mm). Clinical items revealed very healthy peri-implant soft tissues in both groups. Patients' satisfaction scores were high in both groups. 6-mm implants and 11-mm implants combined with sinus floor elevation surgery are equally successful to support a single crown in the resorbed posterior maxilla after 1-year follow-up.

  8. Comparative evaluation of marginal leakage of provisional crowns cemented with different temporary luting cements: In vitro study

    PubMed Central

    Arora, Sheen Juneja; Arora, Aman; Upadhyaya, Viram; Jain, Shilpi

    2016-01-01

    Background or Statement of Problem: As, the longevity of provisional restorations is related to, a perfect adaptation and a strong, long-term union between restoration and teeth structures, therefore, evaluation of marginal leakage of provisional restorative materials luted with cements using the standardized procedures is essential. Aims and Objectives: To compare the marginal leakage of the provisional crowns fabricated from Autopolymerizing acrylic resin crowns and bisphenol A-glycidyl dimethacrylate (BIS-GMA) resin crowns. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin crowns and BIS-GMA resin crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin (SC-10) crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from BIS-GMA resin crowns (Protemp 4) cemented with different temporary luting cements. Methodology: Freshly extracted 60 maxillary premolars of approximately similar dimensions were mounted in dental plaster. Tooth reduction with shoulder margin was planned to use a customized handpiece-holding jig. Provisional crowns were prepared using the wax pattern fabricated from computer aided designing/computer aided manufacturing milling machine following the tooth preparation. Sixty provisional crowns were made, thirty each of SC-10 and Protemp 4 and were then cemented with three different luting cements. Specimens were thermocycled, submerged in a 2% methylene blue solution, then sectioned and observed under a stereomicroscope for the evaluation of marginal microleakage. A five-level scale was used to score dye penetration in the tooth/cement interface and the results of this study was analyzed using the Chi-square test, Mann–Whitney U-test, Kruskal–Wallis H-test and the results were statistically significant P < 0.05 the power of study - 80%. Results: Marginal leakage was significant in both provisional crowns cemented with three different luting cements along the axial walls of teeth (P < 0.05) confidence interval - 95%. Conclusion: The temporary cements with eugenol showed more microleakage than those without eugenol. SC-10 crowns showed more microleakage compared to Protemp 4 crowns. SC-10 crowns cemented with Kalzinol showed maximum microleakage and Protemp 4 crowns cemented with HY bond showed least microleakage. PMID:27134427

  9. Fit of lithium disilicate crowns fabricated from conventional and digital impressions assessed with micro-CT.

    PubMed

    Kim, Jae-Hyun; Jeong, Ji-Hye; Lee, Jin-Han; Cho, Hye-Won

    2016-10-01

    Although the number of lithium disilicate crowns fabricated with computer-aided design and computer-aided manufacturing (CAD-CAM) technology has increased, the accuracy of the prostheses produced by using digital pathways remains unknown. The purpose of this in vitro study was to compare marginal and internal discrepancies of lithium disilicate crowns fabricated from digital and conventional impressions. A typodont mandibular first molar was prepared for a lithium disilicate crown, and 20 duplicate dies were fabricated by milling poly(methyl methacrylate) resin blocks from laboratory scans. Four groups of 5 lithium disilicate crowns each were created by using a CS3500 (Carestream Dental) intraoral digital impression; Trios (3shape) intraoral digital impression; Ceramill Map400 (Amann Girrbach) extraoral digital impression; and a heat-press technique as a control group. All of the IPS e.max CAD (Ivoclar Vivadent AG) crowns were produced using a 5-axis milling engine (Ceramill Motion2). The lithium disilicate crowns were cemented with zinc phosphate cement under finger pressure. Marginal and internal discrepancies were measured using micro-computed tomography (SkyScan1172). One-way ANOVAs with the Tukey honest significant differences test were used for statistical analysis of the data (α=.05). The mean marginal discrepancies of CS3500 lithium disilicate crowns were 129.6 μm, 200.9 μm for Ceramill Map400, and 207.8 μm 176.1 μm for the heat-press technique; and the internal discrepancy volumes for CS3500 were 25.3 mm 3 , 40.7 mm 3 for Trios, 29.1 mm 3 for Ceramill Map400, and 29.1 and 31.4 mm 3 for the heat-press technique. The CS3500 group showed a significantly better marginal discrepancy than the other 3 groups and a smaller internal discrepancy volume than the Trios group (P<.05). Significant differences were found between IPS e.max CAD crowns produced using 2 intraoral digital impressions, whereas no differences were found between IPS e.max CAD crowns produced from an extraoral digital impression and IPS e.max Press crowns produced using a heat-press technique. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    PubMed Central

    ABDULLAH, Adil Othman; TSITROU, Effrosyni A; POLLINGTON, Sarah

    2016-01-01

    ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (P<0.001). The average internal fit was: VITA CAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p<0.001). However, the mode of fracture showed no differences between the groups (p>0.05). Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns. PMID:27383707

  11. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns.

    PubMed

    Abdullah, Adil Othman; Tsitrou, Effrosyni A; Pollington, Sarah

    2016-01-01

    This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (P<0.001). The average internal fit was: VITA CAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p<0.001). However, the mode of fracture showed no differences between the groups (p>0.05). CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  12. Electrospray ionization mass spectrometric investigations of the complexation behavior of macrocyclic thiacrown ethers with bivalent transitional metals (Cu, Co, Ni and Zn).

    PubMed

    Tsybizova, Alexandra; Tarábek, Ján; Buchta, Michal; Holý, Petr; Schröder, Detlef

    2012-10-15

    Heavy metals are both a problem for the environment and an important resource for industry. Their selective extraction by means of organic ligands therefore is an attractive topic. The coordination of three thiacrown ethers to late 3d-metal ions was investigated by a combination of electrospray ionization mass spectrometry (ESI-MS) and electron paramagnetic resonance (EPR). The mass spectrometric experiments were carried out in an ion trap mass spectrometer with an ESI source. Absolute binding constants were estimated by comparison with data for 18-crown-6/Na(+). EPR spectroscopy was used as a complementary method for investigating the Cu(I) /Cu(II) redox couple. The study found that thiacrown ethers preferentially bind traces of copper even at an excess of other metal ions (Co(II), Ni(II), and Zn(II)). The absolute association constants of the Cu(I) complexes were about 10(8) M(-1), and about two orders of magnitude lower for the other 3d-metal cations. The EPR spectra demonstrated that the reduction from Cu(II) to Cu(I) upon formation of the [(thiacrown)Cu](+) species takes place in solution. ESI-MS demonstrated that the three thiacrown ligands examined had high binding constants as well as good selectivities for copper(I) at low concentrations, and in the presence of other metal ions. By a combination of ESI-MS and EPR spectrometry it was shown that the reduction from Cu(II) to Cu(I) occurred in solution. Copyright © 2012 John Wiley & Sons, Ltd.

  13. [A pilot clinical study of immediate provisionalization with a chairside computer aided design and computer aided manufacture monolithic crown for single tooth immediate implant placement].

    PubMed

    Tian, J H; Di, P; Lin, Y; Zhang, Y; Wei, D H; Cui, H Y

    2017-01-09

    Objective: To evaluate the primary clinical outcomes of immediate provisionalization with a monolithic crown utilizing a novel chairside computer aided design and computer aided manufacture (CAD/CAM) workflow for single tooth immediate implant placement. Methods: This pilot study was a prospective within-subjects design. Thirteen consecutive patients were included and diagnosed with untreatable single incisor or premolar with fine general and local anatomical conditions. The trial was conducted at Department of Implantology, Peking University School and Hospital of Stomatology, Beijing, between January 2016 and June 2016. The teeth were extracted atraumatically and implants were immediately placed in the fresh sockets. Two screw-retained interim crowns were fabricated for the same site utilizing different workflows, a monolithic lithium disilicate (LS2) crown produced by CEREC (Sirona, Germany) chairside CAD/CAM system (CER group) and a manually fabricated resin crown utilizing conventional workflow (CONV group) respectively. The patients were blinded to the group allocation of the two interim crowns. After the clinical try-in for both crowns in a randomized sequence, the patients ' level of satisfaction was assessed with a virtual analogue scale (VAS) questionnaire. The restorations chosen by patients themselves were seated in the implants by one experienced prosthodontist. The accuracy, aesthetic effect and clinical time consumption of both groups were compared. Statistical analyses were performed with the Wilcoxon signed rank test. Results: All patients were treated with atraumatic tooth extraction, immediate implant placement using flapless surgery and immediate provisionalization in a single visit. The interim crowns of both groups could be fitted with or without slight adjustments. For each patient, the interim crown of CER group was chosen to be seated with a relatively higher VAS result. The white esthetic score (WES) results demonstrated no statistically significant difference between CER group (7.5±1.1) and CONV group (7.9±0.9) ( P> 0.05). The mean total work time was significantly different resulting in (131.9±5.0) min for CER group and (205.2±6.3) min( P< 0.05). The major difference lied in the laboratory work time, resulting in (113.5±6.3) min for CER group which was significantly shorter than (185.6±6.6) min for CONV group. As for impression taking time, the CER group (7.5±0.8) min was significantly shorter than CONV group (11.7± 1.1) min ( P< 0.05). However, analysis for clinical adjustment time showed a significantly longer time for CER group [(11.0±2.1) min vs (8.0±2.8) min, P< 0.05]. After 3-6 months of observation, the overall survival rate was 100%. Screw loosening occurred in 4 patients and was tightened again. No other major complication soccurred. Conclusions: The full digital workflow utilizing CEREC chairside CAD/CAM system to fabricate interim crowns after immediate implant placement in one single visit was feasible. It was more time-efficient and could effectively shorten the laboratory work time compared to the conventional workflow. Patients demonstrated high satisfaction and there was no statistical difference in WES results compared to the conventional workflow. Favorable clinical outcomes were gained in this short-term follow-up study.

  14. Detection of Catechol by Potentiometric-Flow Injection Analysis in the Presence of Interferents

    ERIC Educational Resources Information Center

    Lunsford, Suzanne K.; Widera, Justyna; Zhang, Hong

    2007-01-01

    This article describes an undergraduate analytical chemistry experiment developed to teach instrumental lab skills while incorporating common interferents encountered in the real-world analysis of catechol. The lab technique incorporates potentiometric-flow injection analysis on a dibenzo-18-crown-6 dual platinum electrode to detect catechol in…

  15. The Complexation of the Na(super +) by 18-Crown-6 Studied via Nuclear Magnetic Resonance

    ERIC Educational Resources Information Center

    Peters, Steven J.; Stevenson, Cheryl D.

    2004-01-01

    A student friendly experiment that teaches several important concepts of modern nuclear magnetic resonance (NMR), like multinuclear capabilities, the NMR time scale, and time-averaged signals, is described along with some important concepts of thermo chemical equilibria. The mentioned experiment involves safe and inexpensive compounds, such as…

  16. Changes in the periodontal condition after replacement of swaged crowns by metal.

    PubMed

    Plotniece-Baranovska, Anita; Soboleva, Una; Rogovska, Irena; Apse, Peteris

    2006-01-01

    Evidence based clinical studies have shown exact recommended design for artificial crown reconstruction with acceptable long-term results taking into an account the biological price. Previous histological and clinical studies proved that fixed prostheses might influence the periodontal condition of crowned teeth, if not all biological criteria have been considered. The aim of the present study was to assess the periodontal condition of the crowned teeth after stainless steel swaged crowns were replaced by cast metal ceramic crowns. Participants were selected at the Institute of Stomatology, Stradin's University. Selection criteria included need to replace existing swaged crowns by metal ceramic crowns for patients with absence of any systemic disease. Following symptoms of periodontal condition were examined - presence of inflammation (clinical signs, probing) and pocket depth. Assessments were carried out at four different points of time (first appointment after replacement existing swaged crowns by temporary crowns; two weeks after cementation of permanent metal ceramic restoration; after three month; after six month). Overall bleeding score "2" and "3" at the first measurement was observed in majority of study population. Bleeding scores between the 1st and the 4th measurement was significantly lower (p<0.01). The same trend was observed also in the reduction of pocket depth. Overall mean value of pocket depth gradually decreased from the 1st till the 4th measurement. Replacement of swaged crowns by metal ceramic improves gingival health and leads to better long-term prognosis for restored teeth. It is recommended that swaged crowns be replaced with more biologically friendly crowns.

  17. An investigation of heat transfer to the implant-bone interface when drilling through a zirconia crown attached to a titanium or zirconia abutment.

    PubMed

    Mason, Amy G; Sutton, Alan; Turkyilmaz, Ilser

    2014-11-01

    Thermal injury to the implant-bone interface may lead to bone necrosis and loss of osseointegration. This is a concern during manipulation of the implant throughout the restorative phase of treatment. The risk of heat transfer to the implant-bone interface during abutment preparation or prosthesis removal should be considered. The purpose of the study was to examine the amount of heat transferred to the implant-bone interface when a zirconia crown is drilled to access the screw channel or section a crown with a high-speed dental handpiece. Of the 64 ceramic-veneered zirconia crowns fabricated, 32 had a coping thickness of 0.5 mm and 32 had a coping thickness of 1.0 mm. The crowns were cemented on either titanium stock abutments or zirconia stock abutments. Each group was further subdivided to evaluate heat transfer when the screw channel was accessed or the crown was sectioned with a high-speed handpiece with or without irrigation. Temperature change was recorded for each specimen at the cervical and apical aspect of the implant with thermocouples and a logging thermometer. ANOVA was used to assess the statistical significance in temperature change between the test combinations, and nonparametric Mann-Whitney U tests were used to evaluate the findings. The use of irrigation during both crown removal processes yielded an average temperature increase of 3.59 ±0.35°C. Crown removal in the absence of irrigation yielded an average temperature increase of 18.76 ±3.09°C. When all parameter combinations in the presence of irrigation were evaluated, the maximum temperature change was below the threshold of thermal injury to bone. The maximum temperature change was above the threshold for thermal injury at the coronal aspect of the implant and below the threshold at the apical aspect in the absence of irrigation. Within the limitations of this investigation, the use of irrigation with a high-speed dental handpiece to remove a ceramic-veneered zirconia crown results in a temperature increase at the implant-bone interface insufficient to cause irreversible damage. Conversely, a lack of irrigation may yield a temperature increase capable of producing irreversible damage at the coronal aspect of the implant. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Human exposure to PCDDs and their precursors from heron and tern eggs in the Yangtze River Delta indicate PCP origin.

    PubMed

    Zhou, Yihui; Yin, Ge; Asplund, Lillemor; Stewart, Kathryn; Rantakokko, Panu; Bignert, Anders; Ruokojärvi, Päivi; Kiviranta, Hannu; Qiu, Yanling; Ma, Zhijun; Bergman, Åke

    2017-06-01

    Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are highly toxic to humans and wildlife. In the present study, PCDD/Fs were analyzed in the eggs of whiskered terns (Chlidonias hybrida), and genetically identified eggs from black-crowned night herons (Nycticorax nycticorax) sampled from two lakes in the Yangtze River Delta area, China. The median toxic equivalent (TEQ) of PCDD/Fs were 280 (range: 95-1500) and 400 (range: 220-1100) pg TEQ g -1 lw (WHO, 1998 for birds) in the eggs of black-crowned night heron and whiskered tern, respectively. Compared to known sources, concentrations of PCDDs relative to the sum of PCDD/Fs in bird eggs, demonstrated high abundance of octachlorodibenzo-p-dioxin (OCDD), 1,2,3,4,6,7,8-heptaCDD and 1,2,3,6,7,8-hexaCDD indicating pentachlorophenol (PCP), and/or sodium pentachlorophenolate (Na-PCP) as significant sources of the PCDD/Fs. The presence of polychlorinated diphenyl ethers (PCDEs), hydroxylated and methoxylated polychlorinated diphenyl ethers (OH- and MeO-PCDEs, known impurities in PCP products), corroborates this hypothesis. Further, significant correlations were found between the predominant congener CDE-206, 3'-OH-CDE-207, 2'-MeO-CDE-206 and OCDD, indicating a common origin. Eggs from the two lakes are sometimes used for human consumption. The WHO health-based tolerable intake of PCDD/Fs is exceeded if eggs from the two lakes are consumed regularly on a weekly basis, particularly for children. The TEQs extensively exceed maximum levels for PCDD/Fs in hen eggs and egg products according to EU legislation (2.5 pg TEQ g -1 lw). The results suggest immediate action should be taken to manage the contamination, and further studies evaluating the impacts of egg consumption from wild birds in China. Likewise, studies on dioxins and other POPs in common eggs need to be initiated around China. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Chairside Computer-Aided Design/Computer-Aided Manufacture All-Ceramic Crown and Endocrown Restorations: A 7-Year Survival Rate Study.

    PubMed

    Fages, Michel; Raynal, Jacques; Tramini, Paul; Cuisinier, Frédéric Jg; Durand, Jean-Cédric

    The objective of the present study was to analyze the clinical outcomes of 447 monoblock ceramic chairside computer-aided design/computer-aided manufacture (CAD/CAM) reconstructions over a 7-year functional period. Of these reconstructions, 212 were peripheral crowns and 235 were endocrowns. The restorations were placed between 2003 and 2008 in a total of 323 patients. They were created using a chairside CAD/CAM method and the same materials in all cases. All of the crowns were manufactured and glued during the same clinical session by the same practitioner. Data were descriptively analyzed and survival probabilities were calculated using Kaplan-Meier statistics. Of the 447 restorations, only 6 failures occurred, resulting in a success rate of 98.66%. All of the failures were the result of a partial ceramic fracture. Of the six ceramic fractures, five appeared on peripheral crowns and one on an endocrown. All fractures appeared in the first 24 months, including two in the first month. Log-rank test comparing incidence rates between crowns and endocrowns showed no significant differences (P = .08). This survival rate study reinforced the use of CAD/CAM full ceramic crowns and endocrowns on molars, showing a much more favorable survival rate for endocrowns.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuz'mina, L. G.; Fedorova, O. A.; Andryukhina, E. N.

    A comparative study of the molecular geometry and crystal packing of crown-containing styryl heterocycles and their dimethoxy substituted analogues is performed. It is established that all the compounds exhibit an identical type of distortions of the geometry of the central styryl fragment. These are the localization of the {pi}-electron density at the ethylene bond and the bond alternation in a half of the phenyl ring due to the conjugation of lone electron pairs of the oxygen substituents with the chromophore system of the molecule. A comparative analysis of the crystal packings of the compounds reveals extended separate hydrophilic and hydrophobicmore » regions. The hydrophilic regions are built of crown ether fragments, and the hydrophobic regions consist of {pi}-conjugated and aromatic molecular fragments. The hydrophobic regions are characterized by a wide variety of packing motifs, among which stacking packing is absent. For two compounds, the formation of sandwich dimers that are preorganized to enter into the photochemical [2 + 2]cycloaddition reaction is observed.« less

  1. Method for liquid chromatographic extraction of strontium from acid solutions

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1992-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  2. Reactions and Interactions in Liquid Crystalline Media

    DTIC Science & Technology

    1991-10-30

    nematic lyophases of potassium laurate, myristyl tri methylammonium bromide or sodium decylsulfate with 1-decanol and 23 water. A strong retardation of the...crystalline polyacrylate crosslinked elastomers were synthesized. 198c 0 0 96 0 0 0O-(CH12 ) 2 -0O(k 97 Crosslinking, up to 10% of structural units produced...in their isotropic state and they work as the transporting phase for the azo-crown ether molecules. The permeation of K+ from a potassium p

  3. Crown Recession Patterns in Three Conifer Species of the Northern Rocky Mountains

    Treesearch

    Sean M. Garber; Robert A. Monserud; Douglas A. Maguire

    2008-01-01

    Crown length is a fundamental tree dimension for characterizing growth potential, wildlife habitat, and wood quality. The relative rates of height growth and crown recession detennine the progression of crown length over time. We investigated patterns in crown recession of three co-occurring species in the northern Rocky Mountains: western white pine (Pinus...

  4. An Index of Competition Based on Relative Crown Position and Size

    Treesearch

    Dwight D. O' Neal; Allan E. Houston; Edward R. Buckner; James S. Meadows

    1995-01-01

    A new competition index, the Crown Position Index (CPI) was evaluated using a 41-year-old, well stocked, upland hardwood stand in southwestern Tennessee. CPI wss based on relative crown position and crown size as expressed by crown projections and relative heights of crop trees and their competitors. Comparisons were made among CPI, the Hegyl (1974)...

  5. High performance planar p-i-n perovskite solar cells with crown-ether functionalized fullerene and LiF as double cathode buffer layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Xiaodong; Zhou, Yi, E-mail: yizhou@suda.edu.cn, E-mail: songbo@suda.edu.cn, E-mail: liyf@iccas.ac.cn; Song, Bo, E-mail: yizhou@suda.edu.cn, E-mail: songbo@suda.edu.cn, E-mail: liyf@iccas.ac.cn

    2015-08-10

    Double cathode buffer layers (CBLs) composed of fullerene derivative functionalized with a crown-ether end group in its side chain (denoted as PCBC) and a LiF layer were introduced between the PCBM acceptor layer and the top cathode in planar p-i-n perovskite solar cells (pero-SCs) based on CH{sub 3}NH{sub 3}PbI{sub 3−X}Cl{sub X}. The devices with the PCBC/LiF double CBLs showed significant improvements in power conversion efficiency (PCE) and long-term stability when compared to the device with LiF single CBL. Through optimizing the spin-coating speed of PCBC, a maximum PCE of 15.53% has been achieved, which is approximately 15% higher than thatmore » of the device with single LiF CBL. The remarkable improvement in PCE can be attributed to the formation of a better ohmic contact in the CBL between PCBC and LiF/Al electrode arising from the dipole moment of PCBC, leading to the enhanced fill factor and short-circuit current density (J{sub sc}). Besides the PCE, the long-term stability of the devices with PCBC interlayer is also superior to that of the device with LiF single CBL, which is due to the more effective protection for the perovskite/PCBM interface.« less

  6. Selective cesium removal from radioactive liquid waste by crown ether immobilized new class conjugate adsorbent.

    PubMed

    Awual, Md Rabiul; Yaita, Tsuyoshi; Taguchi, Tomitsugu; Shiwaku, Hideaki; Suzuki, Shinichi; Okamoto, Yoshihiro

    2014-08-15

    Conjugate materials can provide chemical functionality, enabling an assembly of the ligand complexation ability to metal ions that are important for applications, such as separation and removal devices. In this study, we developed ligand immobilized conjugate adsorbent for selective cesium (Cs) removal from wastewater. The adsorbent was synthesized by direct immobilization of dibenzo-24-crown-8 ether onto inorganic mesoporous silica. The effective parameters such as solution pH, contact time, initial Cs concentration and ionic strength of Na and K ion concentrations were evaluated and optimized systematically. This adsorbent was exhibited the high surface area-to-volume ratios and uniformly shaped pores in case cavities, and its active sites kept open functionality to taking up Cs. The obtained results revealed that adsorbent had higher selectivity toward Cs even in the presence of a high concentration of Na and K and this is probably due to the Cs-π interaction of the benzene ring. The proposed adsorbent was successfully applied for radioactive Cs removal to be used as the potential candidate in Fukushima nuclear wastewater treatment. The adsorbed Cs was eluted with suitable eluent and simultaneously regenerated into the initial form for the next removal operation after rinsing with water. The adsorbent retained functionality despite several cycles during sorption-elution-regeneration operations. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Clinical performance of IPS-Empress 2 ceramic crowns inserted by general dental practitioners.

    PubMed

    Mansour, Yasar F; Al-Omiri, Mahmoud K; Khader, Yousef Saleh; Al-Wahadni, Ahed

    2008-05-01

    The aim of this study was to evaluate the clinical performance of IPS-Empress 2(R) all-ceramic crowns placed by general dental practitioners. Eighty-two IPS-Empress 2 crowns placed in 64 patients (27 females and 37 males) were evaluated. These crowns had been in place for 15.2 to 57.2 months (mean 25.3 months, SD=9.3). Survival analysis was conducted using the Kaplan-Meier method. Of the 82 crowns 93.9% were rated satisfactory. In terms of the integrity of the restorations, fracture was observed in three crowns and two showed a crack upon transillumination. Five crowns were rated unsatisfactory for color match; one for marginal adaptation; and none for discoloration, secondary caries, or sensitivity. IPS-Empress 2(R) is a suitable material to fabricate all-ceramic crowns; when these all-ceramic crowns were inserted by general dental practitioners, they functioned satisfactorily with low failure rates during an observation period ranging between 15.2 to 57.2 months.

  8. Combining UV photodissociation action spectroscopy with electron transfer dissociation for structure analysis of gas-phase peptide cation-radicals.

    PubMed

    Shaffer, Christopher J; Pepin, Robert; Tureček, František

    2015-12-01

    We report the first example of using ultraviolet (UV) photodissociation action spectroscopy for the investigation of gas-phase peptide cation-radicals produced by electron transfer dissociation. z-Type fragment ions (●) Gly-Gly-Lys(+), coordinated to 18-crown-6-ether (CE), are generated, selected by mass and photodissociated in the 200-400 nm region. The UVPD action spectra indicate the presence of valence-bond isomers differing in the position of the Cα radical defect, (α-Gly)-Gly-Lys(+) (CE), Gly-(α-Gly)-Lys(+) (CE) and Gly-Gly-(α-Lys(+))(CE). The isomers are readily distinguishable by UV absorption spectra obtained by time-dependent density functional theory (TD-DFT) calculations. In contrast, conformational isomers of these radical types are calculated to have similar UV spectra. UV photodissociation action spectroscopy represents a new tool for the investigation of transient intermediates of ion-electron reactions. Specifically, z-type cation radicals are shown to undergo spontaneous hydrogen atom migrations upon electron transfer dissociation. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Radical scavenging ability of some compounds isolated from Piper cubeba towards free radicals.

    PubMed

    Aboul-Enein, Hassan Y; Kładna, Aleksandra; Kruk, Irena

    2011-01-01

    The purpose of this study was to identify the antioxidant activity of 16 compounds isolated from Piper cubeba (CNCs) through the extent of their capacities to scavenge free radicals, hydroxyl radical (HO(•)), superoxide anion radical O•(2)(-) and 2,2-diphenyl-1-picrylhydrazyl radical (DPPH(•)), in different systems. Electron paramagnetic resonance (EPR) and 5,5-dimethyl-1-pyrroline-N-oxide, DMPO, as the spin trap, and chemiluminescence techniques were applied. Using the Fenton-like reaction [Fe(II) + H(2)O(2)], CNCs were found to inhibit DMPO-OH radical formation ranging from 5 to 57% at 1.25 mmol L(-1) concentration. The examined CNCs also showed a high DPPH antiradical activity (ranging from 15 to 99% at 5 mmol L(-1) concentration). Furthermore, the results indicated that seven of the 16 tested compounds may catalyse the conversion of superoxide radicals generated in the potassium superoxide/18-crown-6 ether system, thus showing superoxide dismutase-like activity. The data obtained suggest that radical scavenging properties of CNCs might have potential application in many plant medicines. Copyright © 2010 John Wiley & Sons, Ltd.

  10. Adduct simplification in the analysis of cyanobacterial toxins by matrix-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Howard, Karen L; Boyer, Gregory L

    2007-01-01

    A novel method for simplifying adduct patterns to improve the detection and identification of peptide toxins using matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry is presented. Addition of 200 microM zinc sulfate heptahydrate (ZnSO(4) . 7H(2)O) to samples prior to spotting on the target enhances detection of the protonated molecule while suppressing competing adducts. This produces a highly simplified spectrum with the potential to enhance quantitative analysis, particularly for complex samples. The resulting improvement in total signal strength and reduction in the coefficient of variation (from 31.1% to 5.2% for microcystin-LR) further enhance the potential for sensitive and accurate quantitation. Other potential additives tested, including 18-crown-6 ether, alkali metal salts (lithium chloride, sodium chloride, potassium chloride), and other transition metal salts (silver chloride, silver nitrate, copper(II) nitrate, copper(II) sulfate, zinc acetate), were unable to achieve comparable results. Application of this technique to the analysis of several microcystins, potent peptide hepatotoxins from cyanobacteria, is illustrated. Copyright (c) 2007 John Wiley & Sons, Ltd.

  11. Crown cover chart for oak savannas. Forest Service technical brief

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Law, J.R.; Johnson, P.S.; Houf, G.

    1994-07-01

    Although oak savannas have been defined in many ways, they are characterized by scattered trees, largely comprised of oaks, and a sparse ground layer rich in grasses and forbs. The crown cover chart can be used to estimate the crown cover of trees as a percent of total area. Potential applications of the chart include monitoring changes in savanna crown cover, determining needed reductions in crown cover, and defining the savanna state. in restoring savannas that have grown into closed canopy stands, one can use the chart to estimate initial crown cover before restoration work is begun and again aftermore » crown cover has been reduced.« less

  12. Crown profile equations for stand-grown western hemlock trees in northwestern Oregon.

    Treesearch

    David D. Marshall; Gregory P. Johnson; David W. Hann

    2003-01-01

    Crown profile equations were developed for stand-grown western hemlock(Tsuga heterophylla (Raf.) Sarg.) in northwest Oregon. The profile model uses a segmented approach, dividing the crown into an upper and lower portion at the point of the largest crown width (LCW). The model explains about 86% of the variation in crown width when LCW is known but...

  13. Experimental and numerical modeling of shrub crown fire initiation

    Treesearch

    Watcharapong Tachajapong; Jesse Lozano; Shakar Mahalingam; Xiangyang Zhou; David Weise

    2009-01-01

    The transition of fire from dry surface fuels to wet shrub crown fuels was studied using laboratory experiments and a simple physical model to gain a better understanding of the transition process. In the experiments, we investigated the effects of varying vertical distances between surface and crown fuels (crown base height), and of the wind speed on crown fire...

  14. Equations for predicting uncompacted crown ratio based on compacted crown ratio and tree attributes.

    Treesearch

    Vicente J. Monleon; David Azuma; Donald Gedney

    2004-01-01

    Equations to predict uncompacted crown ratio as a function of compacted crown ratio, tree diameter, and tree height are developed for the main tree species in Oregon, Washington, and California using data from the Forest Health Monitoring Program, USDA Forest Service. The uncompacted crown ratio was modeled with a logistic function and fitted using weighted, nonlinear...

  15. Descriptive statistics of tree crown condition in the Southern United States and impacts on data analysis and interpretation

    Treesearch

    KaDonna C. Randolph

    2006-01-01

    The U.S. Department of Agriculture Forest Service, Forest Inventory and Analysis Program (FIA) utilizes visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes and discusses distributions of three FIA crown condition indicators (crown density, crown dieback, and foliage transparency) for trees in the Southern...

  16. Comparison of Parental Satisfaction with Three Tooth-Colored Full-Coronal Restorations in Primary Maxillary Incisors.

    PubMed

    Salami, A; Walia, T; Bashiri, R

    2015-01-01

    To evaluate and compare the parental satisfaction among resin composite strip crown, preveneered stainless steel crown (PVSSC) and the newly introduced pre-fabricated primary zirconia crown for restoring maxillary primary incisors. A prospective clinical study on 39 children with carious or traumatized primary maxillary incisors. They were randomly and equally distributed in three groups and received one of the full-coronal restorations. Children were recalled to evaluate and compare parental satisfaction about performance of crowns after one year through a questionnaire. Parents were satisfied with all three tooth colored full-coronal restoration techniques. A significant relationship was found between colour of PVSSC (p=0.003) and durability of resin strip crowns (p=0.009) with the overall parental satisfaction levels. Parents who gave poor ratings in these two variables however rated their overall acceptance levels as being satisfied. Parental overall satisfaction was highest for zirconia primary crowns followed by resin composite strip crowns and lowest satisfaction was reported for pre-veneered SSCs. Parents were least satisfied with durability of resin composite strip crowns and colour of pre-veneered stainless steel crowns. However, this did not affect their overall satisfaction with these crowns.

  17. Standing intraoral extractions of cheek teeth aided by partial crown removal in 165 horses (2010-2016).

    PubMed

    Rice, M K; Henry, T J

    2018-01-01

    Diseased cheek teeth in horses often require invasive extraction techniques that carry a high rate of complications. Techniques and instrumentation were developed to perform partial crown removal to aid standing intraoral extraction of diseased cheek teeth in horses. To analyse success rates and post-surgical complications in horses undergoing cheek teeth extraction assisted by partial crown removal. Retrospective cohort study. This study included 165 horses with 194 diseased cheek teeth that were extracted orally assisted by partial crown removal between 2010 and 2016. Medical records were analysed, including case details, obtained radiographs, surgical reports and follow-up information. Follow-up information (≥2 months) was obtained for 151 horses (91.5%). There were 95 horses examined post-operatively by the authors and, 16 horses by the referring veterinarian; in 40 horses, post-operative follow up was obtained by informal telephone interviews with the owner. Successful standing intraoral extraction of cheek teeth was obtained in 164/165 horses (99.4%). Twenty-five of these horses (15.2%) required additional intraoral extraction methods to complete the extraction, including minimally invasive transbuccal approach (n = 21) and tooth sectioning (n = 4). There was one (0.6%) horse with intraoral extraction failure that required standing repulsion to complete the extraction. The intraoperative complication of fractured root tips occurred in 11/165 horses (6.7%). Post-operative complications occurred in 6/165 horses (3.6%), including alveolar sequestra (n = 4), mild delay of alveolar healing at 2 months (n = 1), and development of a persistent draining tract secondary to a retained root tip (n = 1). Specialised instrumentation and additional training in the technique are recommended to perform partial crown removal in horses. Horses with cheek teeth extraction by partial crown removal have an excellent prognosis for a positive outcome. The term partial coronectomy is proposed for this technique. © 2017 EVJ Ltd.

  18. Fatigue resistance and microleakage of CAD/CAM ceramic and composite molar crowns.

    PubMed

    Kassem, Amr S; Atta, Osama; El-Mowafy, Omar

    2012-01-01

    The aim of this study was to determine effect of compressive cyclic loading on fatigue resistance and microleakage of monolithic CAD/CAM molar ceramic and composite crowns. Thirty-two extracted molars were prepared to receive CEREC crowns according to manufacturer's guidelines using a special paralleling device (Parallel-A-Prep). Sixteen feldspathic ceramic crowns (VITABLOCS Mark II) (VMII) and 16 resin-composite crowns (Paradigm-MZ100 blocks) (PMZ) were milled using a CEREC-3D machine. Eight crowns of each group were cemented to their respective teeth using self-etching resin cement (Panavia-F-2.0) (PAN), and eight were cemented using self-adhesive resin cement (RelyX-Unicem-Clicker) (RXU). Following storage for 1 week in water, specimens were subjected to uniaxial compressive cyclic loading in an Instron testing machine at 12 Hz for 1,000,000 cycles. Load was applied at the central fossa, and the cycle range was 60-600 N. Specimens were then subjected to microleakage testing. Data were statistically analyzed using factorial ANOVA and Post Hoc (Tukey HSD) tests. All composite crowns survived compressive cyclic loading without fracture, while three ceramic crowns from the subgroup cemented with RXU developed surface cracks at the center of occlusal surfaces, extending laterally. Microleakage scores of ceramic crowns cemented with PAN were significantly lower than those of the other three subgroups (p < 0.05). After 1,000,000 cycles of compressive cyclic loading, PMZ composite molar crowns were more fatigue-resistant than VMII ceramic crowns. Cement type had a significant effect on fatigue resistance of the ceramic crowns but not the composite ones. Microleakage scores of ceramic crowns cemented with PAN were significantly lower than those of the other subgroups (p < 0.05). © 2011 by The American College of Prosthodontists.

  19. Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns

    PubMed Central

    Nawafleh, Noor; Öchsner, Andreas; George, Roy

    2018-01-01

    PURPOSE The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. MATERIALS AND METHODS Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design/computer-aided manufacturing technology and then cemented to zirconia hybrid-abutments (Ti-based). Each group was divided into two subgroups (n=10): (A) control group, crowns were subjected to single load to fracture; (B) test group, crowns underwent chewing simulation using multiple loads for 1.2 million cycles at 1.2 Hz with simultaneous thermocycling between 5℃ and 55℃. Data was statistically analyzed with one-way ANOVA and a Post-Hoc test. RESULTS All tested crowns survived chewing simulation resulting in 100% survival rate. However, wear facets were observed on all the crowns at the occlusal contact point. Fracture load of monolithic lithium disilicate crowns was statistically significantly lower than that of monolithic zirconia crowns. Also, fracture load was significantly reduced in both of the all-ceramic materials after exposure to chewing simulation and thermocycling. Crowns of all test groups exhibited cohesive fracture within the monolithic crown structure only, and no abutment fractures or screw loosening were observed. CONCLUSION When supported by implants, monolithic zirconia restorations cemented to hybrid abutments withstand masticatory forces. Also, fatigue loading accompanied by simultaneous thermocycling significantly reduces the strength of both of the all-ceramic materials. Moreover, further research is needed to define potentials, limits, and long-term serviceability of the materials and hybrid abutments. PMID:29503716

  20. [The value of horizontal discrepancy on the subgingival position of the tooth crown].

    PubMed

    Redzepagić, S

    1997-01-01

    Marginal adaptation of the crown edge has been considered as primary and significant factor of prevention of secondary caries and periodontal disease on carryig tooth. There has been a clear dependence between hunting the periodontal tissue and the quality of edge closing of the crown. If we position subgingivaly the crown which clinically shows a good adoptiveness marginally and at the same time we position marginal crease in the ginguival sucus that should rush the accumulation of the plaque. The bacteries in the plaque would cause the inflammation of ginguive. The end of the crown edge in gingival sucus would cause chronic inflammation at ginguival tissue. The existence of transit zone that includes the crown edge, prepared tooth and dental cement became important if the crown edge has been positioned subgingivaly. If the crown edge ends in the ginguival sucus, the tooth meat is constantly being irritated that results with different degrees of inflammations. In many cases it causes ginguival dislocation. The possibility of clinical control of marginal positioning of subgingivaly positioned crown edge on demarcation line does not exist in terminal phase of cementing. The crown cement can be substratum of bacterial receptiveness and the plaque accumulation in the ginguival sucus. The procedure of cementing is an important cause of incomplete edge closing of the crown on the demarcation line. The form of demarcation line determine the form and the width of crown. They are favorising and degrading the level of marginal adaptations. The existing of horizontal discrepancy at the relation of based tooth--the crown edge is unavoidable. The question is if the amount of this discrepancy fits the assumed biological optimum.

  1. Effect of elasticity on stress distribution in CAD/CAM dental crowns: Glass ceramic vs. polymer-matrix composite.

    PubMed

    Duan, Yuanyuan; Griggs, Jason A

    2015-06-01

    Further investigations are required to evaluate the mechanical behaviour of newly developed polymer-matrix composite (PMC) blocks for computer-aided design/computer-aided manufacturing (CAD/CAM) applications. The purpose of this study was to investigate the effect of elasticity on the stress distribution in dental crowns made of glass-ceramic and PMC materials using finite element (FE) analysis. Elastic constants of two materials were determined by ultrasonic pulse velocity using an acoustic thickness gauge. Three-dimensional solid models of a full-coverage dental crown on a first mandibular molar were generated based on X-ray micro-CT scanning images. A variety of load case-material property combinations were simulated and conducted using FE analysis. The first principal stress distribution in the crown and luting agent was plotted and analyzed. The glass-ceramic crown had stress concentrations on the occlusal surface surrounding the area of loading and the cemented surface underneath the area of loading, while the PMC crown had only stress concentration on the occlusal surface. The PMC crown had lower maximum stress than the glass-ceramic crown in all load cases, but this difference was not substantial when the loading had a lateral component. Eccentric loading did not substantially increase the maximum stress in the prosthesis. Both materials are resistant to fracture with physiological occlusal load. The PMC crown had lower maximum stress than the glass-ceramic crown, but the effect of a lateral loading component was more pronounced for a PMC crown than for a glass-ceramic crown. Knowledge of the stress distribution in dental crowns with low modulus of elasticity will aid clinicians in planning treatments that include such restorations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Fatigue Resistance of CAD/CAM Resin Composite Molar Crowns

    PubMed Central

    Shembish, Fatma A.; Tong, Hui; Kaizer, Marina; Janal, Malvin N.; Thompson, Van P.; Opdam, Niek J.; Zhang, Yu

    2016-01-01

    Objective To demonstrate the fatigue behavior of CAD/CAM resin composite molar crowns using a mouth-motion step-stress fatigue test. Monolithic leucite-reinforced glass-ceramic crowns were used as a reference. Methods Fully anatomically shaped monolithic resin composite molar crowns (Lava Ultimate, n = 24) and leucite reinforced glass-ceramic crowns (IPS Empress CAD, n = 24) were fabricated using CAD/CAM systems. Crowns were cemented on aged dentin-like resin composite tooth replicas (Filtek Z100) with resin-based cements (RelyX Ultimate for Lava Ultimate or Multilink Automix for IPS Empress). Three step-stress profiles (aggressive, moderate and mild) were employed for the accelerated sliding-contact mouth-motion fatigue test. Twenty one crowns from each group were randomly distributed among these three profiles (1:2:4). Failure was designated as chip-off or bulk fracture. Optical and electronic microscopes were used to examine the occlusal surface and subsurface damages, as well as the material microstructures. Results The resin composite crowns showed only minor occlusal damage during mouth-motion step-stress fatigue loading up to 1700 N. Cross-sectional views revealed contact-induced cone cracks in all specimens, and flexural radial cracks in 2 crowns. Both cone and radial cracks were relatively small compared to the crown thickness. Extending these cracks to the threshold for catastrophic failure would require much higher indentation loads or more loading cycles. In contrast, all of the glass-ceramic crowns fractured, starting at loads of approximately 450 N. Significance Monolithic CAD/CAM resin composite crowns endure, with only superficial damage, fatigue loads 3 – 4 times higher than those causing catastrophic failure in glass-ceramic CAD crowns. PMID:26777092

  3. Relation of initial spacing and relative stand density indices to stand characteristics in a Douglas-fir plantation spacing trial

    USGS Publications Warehouse

    Curtis, Robert O.; Bansal, Sheel; Harrington, Constance A.

    2016-01-01

    This report presents updated information on a 1981 Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco var. menziesii) plantation spacing trial at 33 years from planting. Stand statistics at the most recent measurement were compared for initial spacing of 1 through 6 meters and associated relative densities. There was no clear relationship of spacing to top height. Diameter, live crown ratio, and percent survival increased with spacing; basal area and relative density decreased with increase in spacing. Volume in trees ≥ 4 cm diameter was greatest at 2 m spacing, while utilizable volume (trees ≥20 cm dbh) was greatest at 4 m spacing. Live crown ratio decreased and total crown projectional area increased with increasing relative density indices. Total crown projectional area was more closely related to relative density than to basal area.

  4. Markov-random-field-based super-resolution mapping for identification of urban trees in VHR images

    NASA Astrophysics Data System (ADS)

    Ardila, Juan P.; Tolpekin, Valentyn A.; Bijker, Wietske; Stein, Alfred

    2011-11-01

    Identification of tree crowns from remote sensing requires detailed spectral information and submeter spatial resolution imagery. Traditional pixel-based classification techniques do not fully exploit the spatial and spectral characteristics of remote sensing datasets. We propose a contextual and probabilistic method for detection of tree crowns in urban areas using a Markov random field based super resolution mapping (SRM) approach in very high resolution images. Our method defines an objective energy function in terms of the conditional probabilities of panchromatic and multispectral images and it locally optimizes the labeling of tree crown pixels. Energy and model parameter values are estimated from multiple implementations of SRM in tuning areas and the method is applied in QuickBird images to produce a 0.6 m tree crown map in a city of The Netherlands. The SRM output shows an identification rate of 66% and commission and omission errors in small trees and shrub areas. The method outperforms tree crown identification results obtained with maximum likelihood, support vector machines and SRM at nominal resolution (2.4 m) approaches.

  5. [Long-term observation of 920 porcelain fused to metal prostheses].

    PubMed

    Jiang, Yong-Lin; Sun, Jian; Weng, Wei-Min; Zhang, Fu-Qiang

    2006-10-01

    To evaluate the long-term clinical results of porcelain fused to metal prostheses. Since January 1995, 920 porcelain fused to metal prostheses were fabricated. The long-term outcome were evaluated according to the condition of the prosthese, abutment and the periodontal tissue in the respects of successful rate and causes of failure. 74 patients were found to be during the follow up period, including 36 anterior crowns (46 units), 18 posterior crowns (22 units), 12 percentage of anterior bridges and 8 posterior bridges. The overall failure rate was 8.04%, 4.84% for crown, 8.77% for bridge. The failed prostheses was 5.39%. Porcelain fused to metal prostheses is an ideal method for restoration. The standard process both for the clinician and the technician must be obeyed to improve the success rate.

  6. Sapling structure and regeneration strategy in 18 Shorea species co-occurring in a tropical rainforest.

    PubMed

    Aiba, Masahiro; Nakashizuka, Tohru

    2005-08-01

    Inevitable trade-offs in structure may be a basis for differentiation in plant strategies. Juvenile trees in different functional groups are characterized by specific suites of structural traits such as crown architecture and biomass distribution. The relationship between juvenile tree structure and function was tested to find out if it is robust among functionally and taxonomically similar species of the genus Shorea that coexist sympatrically in a tropical rain forest in Borneo. The sapling structures of 18 species were compared for standardized dry masses of 5 and 30 g. Pairwise simple correlation and multiple correlation patterns among structural traits of juveniles (0.1-1.5 m in height) of 18 Shorea species were examined using Pearson's correlation and principal component analysis (PCA), respectively. The correlation was then tested between the PCA results and three indices of shade tolerance: the net photosynthetic rate, the wood density of mature trees and seed size. The structural variation in saplings of the genus Shorea was as large as that found in sets of species with much more diverse origins. The PCA showed that both crown architecture and allocation to leaves are major sources of variation in the structures of the 18 species investigated. Of these two axes, allocation to leaves was significantly correlated with wood density and showed a limited correlation with photosynthetic rate, whereas crown architecture was significantly correlated to seed size. Overall, the results suggest that an allocation trade-off between leaves and other organs, which co-varied with wood density and to a certain extent with photosynthetic capacity, accounts for the difference in shade tolerance among congeneric, functionally similar species. In contrast, the relationship between the architecture and regeneration strategy differed from the pattern found between functional groups, and the function of crown architecture was ambiguous.

  7. Comparison of leaf gas exchange and stable isotope signature of water-soluble compounds along canopy gradients of co-occurring Douglas-fir and European beech.

    PubMed

    Bögelein, Rebekka; Hassdenteufel, Martin; Thomas, Frank M; Werner, Willy

    2012-07-01

    Combined δ(13) C and δ(18) O analyses of water-soluble leaf and twig phloem material were used to determine intrinsic water-use efficiency (iWUE) and variability of stomatal conductance at different crown positions in adult European beech (Fagus sylvatica) and Douglas-fir (Pseudotsuga menziesii) trees. Simultaneous gas exchange measurements allowed evaluation of the differences in calculating iWUE from leaf or phloem water-soluble compounds, and comparison with a semi-quantitative dual isotope model to infer variability of net photosynthesis (A(n) ) between the investigated crown positions. Estimates of iWUE from δ(13) C of leaf water-soluble organic matter (WSOM) outperformed the estimates from phloem compounds. In the beech crown, δ(13) C of leaf WSOM coincided clearly with gas exchange measurements. The relationship was not as reliable in the Douglas-fir. The differences in δ(18) O between leaf and phloem material were found to correlate with stomatal conductance. The semi-quantitative model approach was applicable for comparisons of daily average A(n) between different crown positions and trees. Intracanopy gradients were more pronounced in the beech than in the Douglas-fir, which reached higher values of iWUE at the respective positions, particularly under dry air conditions. © 2012 Blackwell Publishing Ltd.

  8. Stratifying photo plots into volume classes...by crown closure comparator

    Treesearch

    Robert C. Aldrich

    1967-01-01

    As an aid to aerial photo interpretation, a Crown Closure Comparator has been developed. Printed as a positive film transparency, this device shows tree crowns as open dots on a black background. The Comparator is used to stratify I-acre plots into broad volume classes on single aerial photos using 4 crown-diameter and 9 crown-closure classes. It can also be used for...

  9. A numerical rating system for crown classes of southern hardwoods

    Treesearch

    James S. Meadows; E.C. Burkhardt; Robert L. Johnson; John D. Hodges

    2001-01-01

    A numerical rating system to delineate crown classes of southern hardwoods is described. The system is based on four criteria: (1) amount of direct sunlight from above, (2) amount of direct sunlight from the sides, (3) crown balance, and (4) relative crown size. The total point value assigned places the tree within one of the four crown classes. The rating system can...

  10. Development of post-fire crown damage mortality thresholds in ponderosa pine

    Treesearch

    James F. Fowler; Carolyn Hull Sieg; Joel McMillin; Kurt K. Allen; Jose F. Negron; Linda L. Wadleigh; John A. Anhold; Ken E. Gibson

    2010-01-01

    Previous research has shown that crown scorch volume and crown consumption volume are the major predictors of post-fire mortality in ponderosa pine. In this study, we use piecewise logistic regression models of crown scorch data from 6633 trees in five wildfires from the Intermountain West to locate a mortality threshold at 88% scorch by volume for trees with no crown...

  11. Crown-rise and crown-length dynamics: applications to loblolly pine

    Treesearch

    Harry T. Valentine; Ralph L. Amateis; Jeffrey H. Gove; Annikki Makela

    2013-01-01

    The original crown-rise model estimates the average height of a crown-base in an even-aged mono-species stand of trees. We have elaborated this model to reduce bias and prediction error, and to also provide crown-base estimates for individual trees. Results for the latter agree with a theory of branch death based on resource availability and allocation.We use the...

  12. Midday Depression vs. Midday Peak in Diurnal Light Interception: Contrasting Patterns at Crown and Leaf Scales in a Tropical Evergreen Tree.

    PubMed

    Ventre-Lespiaucq, Agustina; Flanagan, Nicola S; Ospina-Calderón, Nhora H; Delgado, Juan A; Escudero, Adrián

    2018-01-01

    Crown architecture usually is heterogeneous as a result of foraging in spatially and temporally heterogeneous light environments. Ecologists are only beginning to identify the importance of temporal heterogeneity for light acquisition in plants, especially at the diurnal scale. Crown architectural heterogeneity often leads to a diurnal variation in light interception. However, maximizing light interception during midday may not be an optimal strategy in environments with excess light. Instead, long-lived plants are expected to show crown architectures and leaf positions that meet the contrasting needs of light interception and avoidance of excess light on a diurnal basis. We expected a midday depression in the diurnal course of light interception both at the whole-crown and leaf scales, as a strategy to avoid the interception of excessive irradiance. We tested this hypothesis in a population of guava trees ( Psidium guajava L.) growing in an open tropical grassland. We quantified three crown architectural traits: intra-individual heterogeneity in foliage clumping, crown openness, and leaf position angles. We estimated the diurnal course of light interception at the crown scale using hemispheric photographs, and at the leaf scale using the cosine of solar incidence. Crowns showed a midday depression in light interception, while leaves showed a midday peak. These contrasting patterns were related to architectural traits. At the crown scale, the midday depression of light interception was linked to a greater crown openness and foliage clumping in crown tops than in the lateral parts of the crown. At the leaf scale, an average inclination angle of 45° led to the midday peak in light interception, but with a huge among-leaf variation in position angles. The mismatch in diurnal course of light interception at crown and leaf scales can indicate that different processes are being optimized at each scale. These findings suggest that the diurnal course of light interception may be an important dimension of the resource acquisition strategies of long-lived woody plants. Using a temporal approach as the one applied here may improve our understanding of the diversity of crown architectures found across and within environments.

  13. Midday Depression vs. Midday Peak in Diurnal Light Interception: Contrasting Patterns at Crown and Leaf Scales in a Tropical Evergreen Tree

    PubMed Central

    Ventre-Lespiaucq, Agustina; Flanagan, Nicola S.; Ospina-Calderón, Nhora H.; Delgado, Juan A.; Escudero, Adrián

    2018-01-01

    Crown architecture usually is heterogeneous as a result of foraging in spatially and temporally heterogeneous light environments. Ecologists are only beginning to identify the importance of temporal heterogeneity for light acquisition in plants, especially at the diurnal scale. Crown architectural heterogeneity often leads to a diurnal variation in light interception. However, maximizing light interception during midday may not be an optimal strategy in environments with excess light. Instead, long-lived plants are expected to show crown architectures and leaf positions that meet the contrasting needs of light interception and avoidance of excess light on a diurnal basis. We expected a midday depression in the diurnal course of light interception both at the whole-crown and leaf scales, as a strategy to avoid the interception of excessive irradiance. We tested this hypothesis in a population of guava trees (Psidium guajava L.) growing in an open tropical grassland. We quantified three crown architectural traits: intra-individual heterogeneity in foliage clumping, crown openness, and leaf position angles. We estimated the diurnal course of light interception at the crown scale using hemispheric photographs, and at the leaf scale using the cosine of solar incidence. Crowns showed a midday depression in light interception, while leaves showed a midday peak. These contrasting patterns were related to architectural traits. At the crown scale, the midday depression of light interception was linked to a greater crown openness and foliage clumping in crown tops than in the lateral parts of the crown. At the leaf scale, an average inclination angle of 45° led to the midday peak in light interception, but with a huge among-leaf variation in position angles. The mismatch in diurnal course of light interception at crown and leaf scales can indicate that different processes are being optimized at each scale. These findings suggest that the diurnal course of light interception may be an important dimension of the resource acquisition strategies of long-lived woody plants. Using a temporal approach as the one applied here may improve our understanding of the diversity of crown architectures found across and within environments. PMID:29904391

  14. Treatment Recommendations for Single-Unit Crowns: Findings from The National Dental Practice-Based Research Network

    PubMed Central

    McCracken, Michael S.; Louis, David R.; Litaker, Mark S.; Minyé, Helena M.; Mungia, Rahma; Gordan, Valeria V.; Marshall, Don G.; Gilbert, Gregg H.

    2016-01-01

    Background Objectives were to: (1) quantify practitioner variation in likelihood to recommend a crown; and (2) test whether certain dentist, practice, and clinical factors are significantly associated with this likelihood. Methods Dentists in the National Dental Practice-Based Research Network completed a questionnaire about indications for single-unit crowns. In four clinical scenarios, practitioners ranked their likelihood of recommending a single-unit crown. These responses were used to calculate a dentist-specific “Crown Factor” (CF; range 0–12). A higher score implies a higher likelihood to recommend a crown. Certain characteristics were tested for statistically significant associations with the CF. Results 1,777 of 2,132 eligible dentists responded (83%). Practitioners were most likely to recommend crowns for teeth that were fractured, cracked, endodontically-treated, or had a broken restoration. Practitioners overwhelmingly recommended crowns for posterior teeth treated endodontically (94%). Practice owners, Southwest practitioners, and practitioners with a balanced work load were more likely to recommend crowns, as were practitioners who use optical scanners for digital impressions. Conclusions There is substantial variation in the likelihood of recommending a crown. While consensus exists in some areas (posterior endodontic treatment), variation dominates in others (size of an existing restoration). Recommendations varied by type of practice, network region, practice busyness, patient insurance status, and use of optical scanners. Practical Implications Recommendations for crowns may be influenced by factors unrelated to tooth and patient variables. A concern for tooth fracture -- whether from endodontic treatment, fractured teeth, or large restorations -- prompted many clinicians to recommend crowns. PMID:27492046

  15. Raman spectral, elemental, crystallinity, and oxygen-isotope variations in conodont apatite during diagenesis

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Cao, Ling; Zhao, Laishi; Algeo, Thomas J.; Chen, Zhong-Qiang; Li, Zhihong; Lv, Zhengyi; Wang, Xiangdong

    2017-08-01

    Conodont apatite has long been used in paleoenvironmental studies, often with minimal evaluation of the influence of diagenesis on measured elemental and isotopic signals. In this study, we evaluate diagenetic influences on conodonts using an integrated set of analytical techniques. A total of 92 points in 19 coniform conodonts from Ordovician marine units of South China were analyzed by micro-laser Raman spectroscopy (M-LRS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), high-resolution X-ray microdiffraction (HXRD), and secondary ion mass spectrometry (SIMS). Each conodont element was analyzed along its full length, including the albid crown, hyaline crown, and basal body, in either a whole specimen (i.e., reflecting the composition of its outer layer) or a split specimen (i.e., reflecting the composition of its interior). In the conodonts of this study, the outer surfaces consist of hydroxyfluorapatite and the interiors of strontian hydroxyfluorapatite. Ionic substitutions resulted in characteristic Raman spectral shifts in the position (SS1) and width (SS2) of the ν1-PO43- stretching band. Although multiple elements were enriched (Sr2+, Mg2+) and depleted (Fe3+, Mn2+, Ca2+) during diagenesis, geochemical modeling constraints and known Raman spectral patterns suggest that Sr uptake was the dominant influence on diagenetic redshifts of SS1. All study specimens show lower SS2 values than modern bioapatite and synthetic apatite, suggesting that band width decreases with time in ancient bioapatite, possibly through an annealing process that produces larger, more uniform crystal domains. Most specimens consist mainly of amorphous or poorly crystalline apatite, which is inferred to represent the original microstructure of conodonts. In a subset of specimens, some tissues (especially albid crown) exhibit an increased degree of crystallinity developed through aggrading neomorphism. However, no systematic relationship was observed between crystallinity and Raman spectral or elemental parameters. Oxygen isotopes show substantial variation within the conodont study specimens. Albid crown is on average 0.28-0.32‰ more depleted in 18O (equivalent to 1.2-1.4 °C higher temperatures) than hyaline crown and basal body, and the interiors of conodont elements are 1.08 ± 0.37‰ more depleted in 18O (equivalent to 3.0-6.4 °C higher temperatures) relative to their outer layers. Although albid crown is widely regarded as better preserved than other conodont tissue types, its 18O-depleted composition and greater development of secondary crystallinity suggest that, in fact, it may be the most strongly altered tissue type. We conclude that Raman spectral, LA elemental, and HXRD microstructural data can provide useful information about the extent of diagenetic alteration of conodont elements, and that such information should be taken into consideration in using conodont elemental and oxygen-isotope data in paleoenvironmental studies.

  16. The marginal fit of lithium disilicate crowns: Press vs. CAD/CAM.

    PubMed

    Azar, Basel; Eckert, Steve; Kunkela, Josef; Ingr, Tomaš; Mounajjed, Radek

    2018-01-01

    This study aimed to compare the vertical marginal gap of teeth restored with lithium disilicate crowns fabricated using CAD/CAM or by pressed ceramic approach. Twenty mandibular third molar teeth were collected after surgical extractions and prepared to receive full veneer crowns. Teeth were optically scanned and lithium disilicate blocks were used to fabricate crowns using CAD/CAM technique. Polyvinyl siloxane impressions of the prepared teeth were made and monolithic pressed lithium disilicate crowns were fabricated. The marginal gap was measured using optical microscope at 200× magnification (Keyence VHX-5000, Japan). Statistical analysis was performed using Wilcoxon test. The lithium disilicate pressed crowns had significantly smaller (p = 0.006) marginal gaps (38 ± 12 μm) than the lithium disilicate CAD/CAM crowns (45 ± 12 μm). This research indicates that lithium disilicate crowns fabricated with the press technique have measurably smaller marginal gaps compared with those fabricated with CAD/CAM technique within in vitro environments. The marginal gaps achieved by the crowns across all groups were within a clinically acceptable range.

  17. [An experimental study on the adaptation of three kinds of porcelain fused-to-metal restorations].

    PubMed

    Pei, Yan-Ping; Chen, Ji-Hua; Chang, Qing; Lin, Song-Shan; Zhang, He

    2009-04-01

    To compare the adaptation of porcelain fused-to-metal (PFM) restorations made from Ni-Cr alloy, precious alloy and galvanized forming copings after cementation and to provide a theory guidance for their application. Three kinds of crowns (Ni-Cr alloy, precious alloy and galvanized forming) were manufactured and cleaned by ultrasonic vibrate with alcoholic solution for 5 minutes, and cemented on their dies as their order. All the crowns were cemented by polycarboxylate zinc-cement and maintained 10 minutes. After coated in the center of methyl acrylic resins, all the samples were cut vertically along buccolingual direction. The cement thickness of PFM was measured by scanning electron microscope and the data were analyzed by multivariate ANOVA. No significant difference was found between the cement thickness of precious alloy crown and galvanized forming crown (P>0.05), while both of these two kinds of crown had significant differences in cement thickness with Ni-Cr crown (P<0.05). The adaptation of precious alloy crown and galvanized forming crown are superior to Ni-Cr crown.

  18. Esthetic Evaluation of Implant Crowns and Peri-Implant Soft Tissue in the Anterior Maxilla: Comparison and Reproducibility of Three Different Indices.

    PubMed

    Tettamanti, Sandro; Millen, Christopher; Gavric, Jelena; Buser, Daniel; Belser, Urs C; Brägger, Urs; Wittneben, Julia-Gabriela

    2016-06-01

    A successful implant reconstruction with optimal esthetics consists of a visually pleasing prosthesis and complete and healthy surrounding soft tissue. In the current literature, numerous indices used to qualitatively assess esthetics have been described. However, studies comparing the indices and their reproducibility are scarce. The aim of this study was to compare three different esthetic indices for the evaluation of single implant-supported crowns. A total of 10 prosthodontists (P), 10 orthodontists (O), 10 general dentists (G), and 10 lay people (L) independently performed the same assessment using 30 photographs and corresponding casts with three different esthetic indices (Peri-Implant and Crown Index [PICI], Implant Crown Aesthetic Index [ICAI], "Pink Esthetic Score/White Esthetic Score [PES/WES]) and repeated the evaluations 4 weeks later. The PES/WES and the PICI showed significantly higher esthetic scores (pink, white, total) and clinical acceptance compared with the ICAI in all four groups and in both assessments. The highest intraobserver agreement was achieved using the PES/WES and the least with the ICAI. The mean Kappa per group ranged from 0.18 (group L with ICAI) to 0.63 (group G with PICI). In comparison with the ICAI, the PES/WES and PICI were more reproducible. Therefore, PES/WES and PICI seem to be more suitable as esthetic indices for single implant crowns. © 2015 Wiley Periodicals, Inc.

  19. Applicability of non-destructive substitutes for leaf area in different stands of Norway spruce (Picea abies L. Karst.) focusing on traditional forest crown measures.

    PubMed

    Laubhann, Daniel; Eckmüllner, Otto; Sterba, Hubert

    2010-09-30

    Since individual tree leaf area is an important measure for productivity as well as for site occupancy, it is of high interest in many studies about forest growth. The exact determination of leaf area is nearly impossible. Thus, a common way to get information about leaf area is to use substitutes. These substitutes are often variables which are collected in a destructive way which is not feasible for long term studies. Therefore, this study aimed at testing the applicability of using substitutes for leaf area which could be collected in a non-destructive way, namely crown surface area and crown projection area. In 8 stands of Norway spruce (Picea abies L. Karst.), divided into three age classes and two thinning treatments, a total of 156 trees were felled in order to test the relationship between leaf area and crown surface area and crown projection area, respectively. Individual tree leaf area of the felled sample trees was estimated by 3P-branch sampling with an accuracy of ±10%. Crown projection area and crown surface area were compared with other, more commonly used, but destructive predictors of leaf area, namely sapwood area at different heights on the bole. Our investigations confirmed findings of several studies that sapwood area is the most precise measure for leaf area because of the high correlation between sapwood area and the leaf area. But behind sapwood area at crown base and sapwood area at three tenth of the tree height the predictive ability of crown surface area was ranked third and even better than that of sapwood area at breast height (R(2) = 0.656 compared with 0.600). Within the stands leaf area is proportional to crown surface area. Using the pooled data of all stands a mixed model approach showed that additionally to crown surface area dominant height and diameter at breast height (dbh) improved the leaf area estimates. Thus, taking dominant height and dbh into account, crown surface area can be recommended for estimating the leaf area of individual trees. The resulting model was in line with many other findings on the leaf area and leaf mass relationships with crown size. From the additional influence of dominant height and dbh in the leaf area model we conclude that the used crown model could be improved by estimating the position of the maximum crown width and the crown width at the base of the crown depending on these two variables.

  20. Applicability of non-destructive substitutes for leaf area in different stands of Norway spruce (Picea abies L. Karst.) focusing on traditional forest crown measures

    PubMed Central

    Laubhann, Daniel; Eckmüllner, Otto; Sterba, Hubert

    2010-01-01

    Since individual tree leaf area is an important measure for productivity as well as for site occupancy, it is of high interest in many studies about forest growth. The exact determination of leaf area is nearly impossible. Thus, a common way to get information about leaf area is to use substitutes. These substitutes are often variables which are collected in a destructive way which is not feasible for long term studies. Therefore, this study aimed at testing the applicability of using substitutes for leaf area which could be collected in a non-destructive way, namely crown surface area and crown projection area. In 8 stands of Norway spruce (Picea abies L. Karst.), divided into three age classes and two thinning treatments, a total of 156 trees were felled in order to test the relationship between leaf area and crown surface area and crown projection area, respectively. Individual tree leaf area of the felled sample trees was estimated by 3P-branch sampling with an accuracy of ±10%. Crown projection area and crown surface area were compared with other, more commonly used, but destructive predictors of leaf area, namely sapwood area at different heights on the bole. Our investigations confirmed findings of several studies that sapwood area is the most precise measure for leaf area because of the high correlation between sapwood area and the leaf area. But behind sapwood area at crown base and sapwood area at three tenth of the tree height the predictive ability of crown surface area was ranked third and even better than that of sapwood area at breast height (R2 = 0.656 compared with 0.600). Within the stands leaf area is proportional to crown surface area. Using the pooled data of all stands a mixed model approach showed that additionally to crown surface area dominant height and diameter at breast height (dbh) improved the leaf area estimates. Thus, taking dominant height and dbh into account, crown surface area can be recommended for estimating the leaf area of individual trees. The resulting model was in line with many other findings on the leaf area and leaf mass relationships with crown size. From the additional influence of dominant height and dbh in the leaf area model we conclude that the used crown model could be improved by estimating the position of the maximum crown width and the crown width at the base of the crown depending on these two variables. PMID:21072126

  1. Effects of crown release on growth and quality of even-aged red maple stands

    Treesearch

    Terry F. Strong; Audra E. Hubbell; Adam H. Weise; Gayne G. Erdmann

    2006-01-01

    The effects of six crown-release treatments on growth and bole quality of 54 dominant, codominant, and intermediate red maples (Acer rubrum L.) were examined in an even-aged stand in upper Michigan. Treatments included an unreleased control, a single-tree and a two-tree crown release, and a full crown-to-crown release of 5, 10, and 15ft. Twenty-two...

  2. Fracture resistance of a selection of full-contour all-ceramic crowns: an in vitro study.

    PubMed

    Zesewitz, Tim F; Knauber, Andreas W; Nothdurft, Frank P

    2014-01-01

    This study aimed to evaluate the fracture resistance of monolithic single crowns made from zirconia (ZI), lithium disilicate (LS2), or feldspar ceramic (FC). Five groups of crowns representing a maxillary first molar were made with the appropriate dimensions according to the manufacturer's instructions. The ZI and LS2 crowns were luted adhesively or cemented conventionally on a metal abutment tooth analog. The feldspar ceramic crowns were luted adhesively. All specimens underwent axial loading until fracture. The crowns in the ZI groups possessed the highest fracture resistance independent of the mode of fixation.

  3. CAD/CAM glass ceramics for single-tooth implant crowns: a finite element analysis.

    PubMed

    Akça, Kvanç; Cavusoglu, Yeliz; Sagirkaya, Elcin; Aybar, Buket; Cehreli, Murat Cavit

    2013-12-01

    To evaluate the load distribution of CAD/CAM mono-ceramic crowns supported with single-tooth implants in functional area. A 3-dimensional numerical model of a soft tissue-level implant was constructed with cement-retained abutment to support glass ceramic machinable crown. Implant-abutment complex and the retained crown were embedded in a Ø 1.5 × 1.5 cm geometric matrix for evaluation of mechanical behavior of mono-ceramic CAD/CAM aluminosilicate and leucite glass crown materials. Laterally positioned axial load of 300 N was applied on the crowns. Resulting principal stresses in the mono-ceramic crowns were evaluated in relation to different glass ceramic materials. The highest compressive stresses were observed at the cervical region of the buccal aspect of the crowns and were 89.98 and 89.99 MPa, for aluminosilicate and leucite glass ceramics, respectively. The highest tensile stresses were observed at the collar of the lingual part of the crowns and were 24.54 and 25.39 MPa, respectively. Stresses induced upon 300 N static loading of CAD/CAM aluminosalicate and leucite glass ceramics are below the compressive strength of the materials. Impact loads may actuate the progress to end failure of mono-ceramic crowns supported by metallic implant abutments.

  4. Wear Behavior of Ceramic CAD/CAM Crowns and Natural Antagonists

    PubMed Central

    Naumova, Ella A.; Schneider, Stephan; Arnold, Wolfgang H.; Piwowarczyk, Andree

    2017-01-01

    Objective: Evaluation of wear behavior of computer-aided design/computer-aided manufacturing (CAD/CAM) crowns from various restorative materials and natural antagonists. Method: Full CAD/CAM crowns fabricated with nanoceramic resin (Lava Ultimate (LU)), a glass ceramic in a resin interpenetrating matrix (Vita Enamic (VE)) and a lithium silicate reinforced ceramic enriched with zirconia (Vita Suprinity (VS)) were cemented on human molars. The crown and antagonists were subjected to simulated chewing. 3D data sets, before and after the chewing simulation, were generated and matched. Occlusal surface roughness, vertical and volume loss of the crowns and antagonists were analyzed. Results: Crown roughness was significantly different between the LU and VE groups after chewing simulation. Crown vertical loss differed in all groups. The highest crown volume loss was found in the LU group, and the lowest in the VE group. Comparisons between the LU and VE groups and the LU and VS groups were significantly different. The highest antagonist volume loss was reached in the VE group, the lowest was in the LU group. Conclusion: Roughness increased after chewing simulation. LU crowns are the most natural antagonist-friendly; these were the most susceptible to vertical and volume loss. Of the tested materials, the VE crowns are the most stable regarding occlusion. PMID:28772602

  5. Productivity of 'Triple Crown' blackberry on the rotating cross-arm trellis system

    USDA-ARS?s Scientific Manuscript database

    Blackberry plants are vigorous and produce long lateral canes. However, to keep the plant canopy narrow for better spray coverage and to aid in fruit harvesting, the canes are typically pruned severely (e.g. primocanes are topped at the 6-ft height and the lateral canes are cut back to 18- to 24-in...

  6. The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading.

    PubMed

    Cameron, Stephen M; Morris, W Jack; Keesee, Stephen M; Barsky, Todd B; Parker, M Harry

    2006-06-01

    Clinicians have used resistance form as a basis for determining guidelines for preparation design to ensure clinical success of cemented cast restorations. Disagreement on whether clinical success follows the on-off or linear nature of resistance form continues. The purpose of this study was to evaluate the number of cycles required to dislodge a cemented complete crown casting under a cyclic lateral load as a function of taper and to compare this relationship for the resistive and nonresistive ranges of taper. Three dies were milled from stainless steel at each of the following tapers: 4, 8, 12, 16, 20, 24, 28, and 32 degrees. A gold-palladium metal-ceramic alloy crown was fabricated for each die, cemented, and subjected to lateral cyclic loading until failure or 1,000,000 cycles. The limiting taper for the dies with their given height and base was 26.6 degrees. Dies with taper less than 26.6 degrees had resistance form, whereas dies with taper larger than 26.6 degrees did not. A linear regression (alpha=.05) was used to evaluate the relation of cycles at dislodgement to taper. The average number of cycles to crown dislodgement or completion for each taper (SD), in units of 10,000, was as follows: 4 degrees, 100 (0); 8 degrees, 100 (0); 12 degrees, 93.54 (16.56); 16 degrees, 61.33 (38.47); 20 degrees, 25.73 (34.67); 24 degrees, 4.33 (7.36); 28 degrees, 0.06 (0.08); and 32 degrees, 0.05 (0.09). The crowns in the resistive area less than 26.6 degrees that demonstrated failure showed a linear regression with a correlation coefficient of -0.995 between the average number of cycles to dislodge the crown and the taper. The slope was significantly different from zero (P=.0048), with a value of -7.58 and a standard error of 0.53. The number of cycles required to cause crown dislodgement was linear after 12 degrees in the resistive area and nearly zero for preparations in the nonresistive area. The limiting taper concept closely predicted the transition point where the slope of the graph of cycles to dislodgement as a function of taper abruptly changed.

  7. Incisor crown bending strength correlates with diet and incisor curvature in anthropoid primates.

    PubMed

    Deane, Andrew S

    2015-02-01

    Anthropoid incisors are large relative to the postcanine dentition and function in the preprocessing of food items. Previous analyses of anthropoid incisor allometry and shape demonstrate that incisor morphology is correlated with preferred foods and that more frugivorous anthropoids have larger and more curved incisors. Although the relationship between incisal crown curvature and preferred foods has been well documented in extant and fossil anthropoids, the functional significance of curvature variation has yet to be conclusively established. Given that an increase in crown curvature will increase maximum linear crown dimensions, and bending resistance is a function of linear crown dimensions, it is hypothesized that incisor crown curvature functons to increase incisor crown resistance to bending forces. This study uses beam theory to calculate the mesiodistal and labiolingual bending strengths of the maxillary and mandibular incisors of hominoid and platyrrhine taxa with differing diets and variable degrees of incisal curvature. Results indicate that bending strength correlates with incisal curvature and that frugivores have elevated incisor bending resistance relative to folivores. Maxillary central incisor bending strengths further discriminate platyrrhine and hominoid hard- and soft-object frugivores suggesting this crown is subjected to elevated occlusal loading relative to other incisors. These results are consistent with the hypothesis that incisor crown curvature functions to increase incisor crown resistance to bending forces but does not preclude the possibility that incisor bending strength is a composite function of multiple dentognathic variables including, but not limited to, incisor crown curvature. © 2014 Wiley Periodicals, Inc.

  8. Modelling available crown fuel for Pinus pinaster Ait. stands in the "Cazorla, Segura and Las Villas Natural Park" (Spain).

    PubMed

    Molina, Juan Ramón; Rodríguez y Silva, Francisco; Mérida, Enrique; Herrera, Miguel Ángel

    2014-11-01

    One of the main limiting aspects in the application of crown fire models at landscape scale has been the uncertainty derived to describe canopy fuel stratum. Available crown fuel and canopy bulk density are essential in order to simulate crown fire behaviour and are of potential use in the evaluation of silvicultural treatments. Currently, the more accurate approach to estimate these parameters is to develop allometric models from common stand inventory data. In this sense, maritime pine (Pinus pinaster Aiton) trees were destructively sampled in the South of the Iberian Peninsula, covering natural and artificial stands. Crown fine fuel was separated into size classes and allometric equations that estimate crown fuel load by biomass fractions were developed. Available crown fuel was determined according to the fuel load differences between un-burned and burned trees with similar characteristics. Taking our destructive post-fire inventory into account, available crown fuel was estimated as the sum of needles biomass, 87.63% of the twigs biomass and 62.79% of the fine branches biomass. In spite of the differences between natural and artificial stands, generic models explained 82% (needles biomass), 89% (crown fuel), 92% (available crown fuel) and 94% (canopy bulk density) of the observed variation. Inclusion of the fitted models in fire management decision-making can provide a decision support system for assessing the potential crown fire of different silvicultural alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Effect of different resin luting cements on the marginal fit of lithium disilicate pressed crowns.

    PubMed

    Mounajjed, Radek; Salinas, Thomas J; Ingr, Tomas; Azar, Basel

    2017-11-15

    The vertical marginal discrepancy of restorations can increase upon cementation, and poor marginal fit can lead to cement dissolution, marginal discoloration, microleakage, and secondary caries. The amount of increase is related to the type of luting cement used, but how lithium disilicate pressed crowns are affected by different resin cements is unclear. The purpose of this in vitro study was to compare the effect of using different resin luting cements on the vertical marginal discrepancy of lithium disilicate pressed crowns. A total of 18 intact extracted mandibular third molars were disinfected in a solution of 10% formalin for 7 days and were then prepared to receive a ceramic crown. Impressions were made with polyvinyl siloxane and lithium disilicate pressed crowns made and cemented with 1 of 3 resin luting cements. The marginal discrepancy was measured at 4 points on the finishing line of each tooth, with optical microscopy at ×200 magnification before and after cementation. Statistical analysis was done with the Kruskal-Wallis test to compare the median marginal increase among the 3 groups. The least amount of marginal increase after cementation was with Harvard PremiumFlow cement, with an average marginal increase of 42 ±11 μm. RelyX Ultimate cement increased the margins by an average 45 ±29 μm. The highest marginal increase was found in the Enamel Plus HRi preheated composite resin group (116 ±47 μm). The marginal increase of pressed crowns cemented with preheated composite resin (Enamel Plus HRi) exceeded the clinically acceptable range of marginal discrepancy. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Aesthetic outcome of single-tooth implant restorations following early implant placement and guided bone regeneration: crown and soft tissue dimensions compared with contralateral teeth.

    PubMed

    Cosyn, Jan; De Rouck, Tim

    2009-10-01

    The aim of this study was to compare crown and soft tissue dimensions of single-tooth implant restorations following early implant placement and guided bone regeneration (GBR) with contralateral non-restored teeth. Twenty-seven patients treated by one and the same surgeon and prosthodontist to restore a single-tooth gap with a class I bone defect in the premaxilla by means of an implant-supported restoration were reviewed. Patients were examined at least 6 months following placement of the crown. All implants had been inserted 6-8 weeks following tooth extraction in conjunction with GBR. At evaluation, crown dimensions, soft tissue dimensions, clinical conditions and patients' aesthetic satisfaction were assessed by one clinician who had not been involved in the treatment. Implant-supported crowns were not significantly longer than contralateral teeth and midfacial soft tissues showed comparable levels after on average 21 months of function. Our data also indicated significant papilla loss especially at the distal aspect of the implants. As the patient's aesthetic appreciation was favourable in 88% of the cases, this appeared to be of trivial importance. Favourable aesthetics may be achieved for single-tooth implant restorations following early implant placement and GBR. The impact of the latter on papilla levels, however, remains to be determined in longitudinal studies.

  11. Ozone curbs crown rust

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1970-01-01

    Crown rust, the most destructive disease of oats, was suppressed in laboratory fumigation chambers by ozone air pollution levels commonly surpassed in many areas. Whether the effects of air pollution on crown rust are of economic importance under field conditions is yet to be determined. Crown rust, caused by the fungus Puccinia coronata, is particularly destructive in Southern and North Central States, often reducing yields 20 percent or more. Rust pustules on oats were significantly smaller when plants were exposed to 10 parts per hundred million ozone for 6 hours in the light on the 10 days after infection. Aboutmore » half as many rust spores were produced in the ozone chamber as in one protected by carbon filters. Exposure to 10 pphm ozone did not affect viability of spores. Spores produced on exposed plants germinated and penetrated stomates of oat leaves as well as spores produced on unexposed leaves.« less

  12. Fracture strength of lithium disilicate crowns compared to polymer-infiltrated ceramic-network and zirconia reinforced lithium silicate crowns.

    PubMed

    Sieper, Kim; Wille, Sebastian; Kern, Matthias

    2017-10-01

    The aim of this study was to evaluate the fracture strength of crowns made from current CAD/CAM materials. In addition the influence of crown thickness and chewing simulation on the fracture strength was evaluated. Crowns were fabricated from lithium disilicate, zirconia reinforced lithium silicate (ZLS-ceramic) and a polymer-infiltrated ceramic-network (PICN) with an occlusal thickness of 1.0mm or 1.5mm, respectively (n=16). Crowns were cemented on composite dies. Subgroups of eight specimens were loaded with 5kg in a chewing simulator for 1,200,000 cycles with thermal cycling. Finally, all specimens were loaded until fracture in a universal testing machine. Three-way ANOVA was used to detect statistical interaction. Differences regarding the materials were tested with two-way ANOVA, following one-way ANOVA and a post-hoc Tukey's-Test. All crowns survived the chewing simulation. The material had a significant influence on the fracture resistance (p≤0.05). Lithium disilicate achieved the highest values of fracture strength in almost all groups followed by ZLS-ceramic. PICN achieved the lowest values of fracture strength. Chewing simulation increased the fracture strength of thick lithium disilicate crown significantly. Greater occlusal thickness of all crown materials resulted in higher crown fracture strength before chewing simulation. After chewing simulation occlusal thickness of lithium disilicate and PICN crowns had no significant influence on the fracture strength. All crowns revealed fracture strength above the clinically expected loading forces. Therefore the durability of the tested CAD/CAM materials seems promising also in an occlusal thickness of 1.0mm. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. The effect of adhesive failure and defects on the stress distribution in all-ceramic crowns.

    PubMed

    Liu, Yonggang; Xu, Yuanzhi; Su, Bo; Arola, Dwayne; Zhang, Dongsheng

    2018-05-29

    To explore the effect of adhesive failure and defects between the crown and cement on the stress distribution within all-ceramic crowns and the corresponding risk of failure. An IPS e.max crown of lithium disilicate produced by CAD/CAM for a first mandibular molar was modeled using finite element analysis based on X-ray micro-CT scanned images. Predefined debonding states and interfacial defects between the crown and cement were simulated using the model. The first principal stress distribution of the crown and cement was analyzed under a vertical occlusal load of 600 N. A concept of failure risk was proposed to evaluate the crown. Stress concentrations in the crown were identified on the occlusal surface surrounding the region of loading, beneath the area of loading and at the margin of the interior surface. Stress concentrations in the cement were also evident at the boundary of the debonded areas. The lower surface of the crown is safe to sustain the 600 N vertical load, but the top surface of the cement would undergo cohesive failure. According to the evaluation of failure risk of the crown, the conditions of highest risk corresponded to the conditions with highest percentage of cement damage. The risk of failure is not only associated with debonding between the crown and cement, but also associated with its distribution. Debonding related defects and cementing defects are more deleterious to the interfacial stress than debonding itself. The axial wall plays a critical role in maintaining the principal tensile stress of the crown at an acceptable level. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. [Preliminary evaluation of clinical effect of computer aided design and computer aided manufacture zirconia crown].

    PubMed

    Wang, Yu-guang; Xing, Yan-xi; Sun, Yu-chun; Zhao, Yi-jiao; Lü, Pei-jun; Wang, Yong

    2013-06-01

    To evaluate clinical effects of computer aided design and computer aided manufacturing (CAD/CAM) milled zirconia crown in three aspects: aesthetic, contact wear and fracture. Sixty patients were divided into two groups.In one group, 35 full contour CAD/CAM zirconia crown were made on molars of 30 patients. The manufacturing process of zirconia crown was as follow. First, the three dimensional(3-D) data of working models, antagonist impression and check records were acquired by 3-D laser scanning Dental wings S50. Then full contour zirconia crowns, which had functional occlusal contacts with antagonistic teeth, and appropriate contact with adjacent teeth were designed with Zeno-CAD(V4.2.5.5.12919) software. ZENOSTAR Zr pure zirconia material was milled in digital controlled machine WIELAND 4030 M1.In the end, the zirconia crown were completed with the method of second sintering and polishing. After clinical try-in, the crown was cemented.In the control group, thirty gold alloy full crown were made and cemented on molars of 30 patients. According to the modified U S Public Health Service Criteria(USPHS) evaluation standard, all crowns were evaluated on the same day, at three months, half a year, one year and two years following delivery. There were three aspects we were focusing on in the evaluation: aesthetic, contact wear(restoration and antagonist), and fracture. In all the prosthesis we evaluated during the 24 months, no fracture was found. Contact wear of crowns varies according to different antagonist teeth. The zirconia crowns show privilege in aesthesis, toughness and anti-wearing.However, there is contact wear on antagonistic natural teeth. Thus it is a good choice when full zirconia crowns are indicated on two antagonistic teeth in both jaws.

  15. Chelation of heavy group 2 (radio)metals by p-tert-butylcalix[4]arene-1,3-crown-6 and logK determination via NMR

    NASA Astrophysics Data System (ADS)

    Bauer, David; Gott, Matthew; Steinbach, Jörg; Mamat, Constantin

    2018-06-01

    A crown-bridged calix[4]arene scaffold was investigated as lead compound for the ligation of heavy alkaline earth metals such as strontium and barium, which appear to be useful for radiopharmaceutical applications in diagnosis as well as in radiotherapy. In particular barium, due to its chemical similarities, could serve as a surrogate for radium, a metal of high radiopharmaceutical interest. The ability of p-tert-butylcalix[4]arene-1,3-crown-6 (1) in particular to chelate cations, such as group 1 and 2 metal ions or ammonium ions is well known. Also, the manifold possibilities of structural modification on the upper- and lower-rim as well as on the crown itself produce properties that may lead to a highly selective and effective chelating agent. In this work, titration experiments of the perchlorate salts of Ba2+, Sr2+ and Pb2+ with ligand 1 were performed to determine their stability constants (logK = 4.7, 4.3, and 3.3, respectively) by 1H NMR measurements in acetonitrile-d3.

  16. The expression of light-related leaf functional traits depends on the location of individual leaves within the crown of isolated Olea europaea trees

    PubMed Central

    Escribano-Rocafort, Adrián G.; Ventre-Lespiaucq, Agustina B.; Granado-Yela, Carlos; Rubio de Casas, Rafael; Delgado, Juan A.; Balaguer, Luis

    2016-01-01

    Background The spatial arrangement and expression of foliar syndromes within tree crowns can reflect the coupling between crown form and function in a given environment. Isolated trees subjected to high irradiance and concomitant stress may adjust leaf phenotypes to cope with environmental gradients that are heterogeneous in space and time within the tree crown. The distinct expression of leaf phenotypes among crown positions could lead to complementary patterns in light interception at the crown scale. Methods We quantified eight light-related leaf traits across 12 crown positions of ten isolated Olea europaea trees in the field. Specifically, we investigated whether the phenotypic expression of foliar traits differed among crown sectors and layers and five periods of the day from sunrise to sunset. We investigated the consequences in terms of the exposed area of the leaves at the tree scale during a single day. Key Results All traits differed among crown positions except the length-to-width ratio of the leaves. We found a strong complementarity in the patterns of the potential exposed area of the leaves among day periods as a result of a non-random distribution of leaf angles across the crown. Leaf exposure at the outer layer was below 60 % of the displayed surface, reaching maximum interception during morning periods. Daily interception increased towards the inner layer, achieving consecutive maximization from east to west positions within the crown, matching the sun’s trajectory. Conclusions The expression of leaf traits within isolated trees of O. europaea varies continuously through the crown in a gradient of leaf morphotypes and leaf angles depending on the exposure and location of individual leaves. The distribution of light-related traits within the crown and the complementarity in the potential exposure patterns of the leaves during the day challenges the assumption of low trait variability within individuals. PMID:26944783

  17. Linking ice accretion and crown structure: towards a model of the effect of freezing rain on tree canopies

    PubMed Central

    Nock, Charles A.; Lecigne, Bastien; Taugourdeau, Olivier; Greene, David F.; Dauzat, Jean; Delagrange, Sylvain; Messier, Christian

    2016-01-01

    Background and Aims Despite a longstanding interest in variation in tree species vulnerability to ice storm damage, quantitative analyses of the influence of crown structure on within-crown variation in ice accretion are rare. In particular, the effect of prior interception by higher branches on lower branch accumulation remains unstudied. The aim of this study was to test the hypothesis that intra-crown ice accretion can be predicted by a measure of the degree of sheltering by neighbouring branches. Methods Freezing rain was artificially applied to Acer platanoides L., and in situ branch-ice thickness was measured directly and from LiDAR point clouds. Two models of freezing rain interception were developed: ‘IceCube’, which uses point clouds to relate ice accretion to a voxel-based index (sheltering factor; SF) of the sheltering effect of branch elements above a measurement point; and ‘IceTree’, a simulation model for in silico evaluation of the interception pattern of freezing rain in virtual tree crowns. Key Results Intra-crown radial ice accretion varied strongly, declining from the tips to the bases of branches and from the top to the base of the crown. SF for branches varied strongly within the crown, and differences among branches were consistent for a range of model parameters. Intra-crown variation in ice accretion on branches was related to SF (R2 = 0·46), with in silico results from IceTree supporting empirical relationships from IceCube. Conclusions Empirical results and simulations confirmed a key role for crown architecture in determining intra-crown patterns of ice accretion. As suspected, the concentration of freezing rain droplets is attenuated by passage through the upper crown, and thus higher branches accumulate more ice than lower branches. This is the first step in developing a model that can provide a quantitative basis for investigating intra-crown and inter-specific variation in freezing rain damage. PMID:27107412

  18. DNA Methylation Mediated Control of Gene Expression Is Critical for Development of Crown Gall Tumors

    PubMed Central

    Kneitz, Susanne; Weber, Dana; Fuchs, Joerg; Hedrich, Rainer; Deeken, Rosalia

    2013-01-01

    Crown gall tumors develop after integration of the T-DNA of virulent Agrobacterium tumefaciens strains into the plant genome. Expression of the T-DNA–encoded oncogenes triggers proliferation and differentiation of transformed plant cells. Crown gall development is known to be accompanied by global changes in transcription, metabolite levels, and physiological processes. High levels of abscisic acid (ABA) in crown galls regulate expression of drought stress responsive genes and mediate drought stress acclimation, which is essential for wild-type-like tumor growth. An impact of epigenetic processes such as DNA methylation on crown gall development has been suggested; however, it has not yet been investigated comprehensively. In this study, the methylation pattern of Arabidopsis thaliana crown galls was analyzed on a genome-wide scale as well as at the single gene level. Bisulfite sequencing analysis revealed that the oncogenes Ipt, IaaH, and IaaM were unmethylated in crown galls. Nevertheless, the oncogenes were susceptible to siRNA–mediated methylation, which inhibited their expression and subsequently crown gall growth. Genome arrays, hybridized with methylated DNA obtained by immunoprecipitation, revealed a globally hypermethylated crown gall genome, while promoters were rather hypomethylated. Mutants with reduced non-CG methylation developed larger tumors than the wild-type controls, indicating that hypermethylation inhibits plant tumor growth. The differential methylation pattern of crown galls and the stem tissue from which they originate correlated with transcriptional changes. Genes known to be transcriptionally inhibited by ABA and methylated in crown galls became promoter methylated upon treatment of A. thaliana with ABA. This suggests that the high ABA levels in crown galls may mediate DNA methylation and regulate expression of genes involved in drought stress protection. In summary, our studies provide evidence that epigenetic processes regulate gene expression, physiological processes, and the development of crown gall tumors. PMID:23408907

  19. DNA methylation mediated control of gene expression is critical for development of crown gall tumors.

    PubMed

    Gohlke, Jochen; Scholz, Claus-Juergen; Kneitz, Susanne; Weber, Dana; Fuchs, Joerg; Hedrich, Rainer; Deeken, Rosalia

    2013-01-01

    Crown gall tumors develop after integration of the T-DNA of virulent Agrobacterium tumefaciens strains into the plant genome. Expression of the T-DNA-encoded oncogenes triggers proliferation and differentiation of transformed plant cells. Crown gall development is known to be accompanied by global changes in transcription, metabolite levels, and physiological processes. High levels of abscisic acid (ABA) in crown galls regulate expression of drought stress responsive genes and mediate drought stress acclimation, which is essential for wild-type-like tumor growth. An impact of epigenetic processes such as DNA methylation on crown gall development has been suggested; however, it has not yet been investigated comprehensively. In this study, the methylation pattern of Arabidopsis thaliana crown galls was analyzed on a genome-wide scale as well as at the single gene level. Bisulfite sequencing analysis revealed that the oncogenes Ipt, IaaH, and IaaM were unmethylated in crown galls. Nevertheless, the oncogenes were susceptible to siRNA-mediated methylation, which inhibited their expression and subsequently crown gall growth. Genome arrays, hybridized with methylated DNA obtained by immunoprecipitation, revealed a globally hypermethylated crown gall genome, while promoters were rather hypomethylated. Mutants with reduced non-CG methylation developed larger tumors than the wild-type controls, indicating that hypermethylation inhibits plant tumor growth. The differential methylation pattern of crown galls and the stem tissue from which they originate correlated with transcriptional changes. Genes known to be transcriptionally inhibited by ABA and methylated in crown galls became promoter methylated upon treatment of A. thaliana with ABA. This suggests that the high ABA levels in crown galls may mediate DNA methylation and regulate expression of genes involved in drought stress protection. In summary, our studies provide evidence that epigenetic processes regulate gene expression, physiological processes, and the development of crown gall tumors.

  20. Effects of Mountain Pine Beetle on Fuels and Expected Fire Behavior in Lodgepole Pine Forests, Colorado, USA

    PubMed Central

    Schoennagel, Tania; Veblen, Thomas T.; Negron, José F.; Smith, Jeremy M.

    2012-01-01

    In Colorado and southern Wyoming, mountain pine beetle (MPB) has affected over 1.6 million ha of predominantly lodgepole pine forests, raising concerns about effects of MPB-caused mortality on subsequent wildfire risk and behavior. Using empirical data we modeled potential fire behavior across a gradient of wind speeds and moisture scenarios in Green stands compared three stages since MPB attack (Red [1–3 yrs], Grey [4–10 yrs], and Old-MPB [∼30 yrs]). MPB killed 50% of the trees and 70% of the basal area in Red and Grey stages. Across moisture scenarios, canopy fuel moisture was one-third lower in Red and Grey stages compared to the Green stage, making active crown fire possible at lower wind speeds and less extreme moisture conditions. More-open canopies and high loads of large surface fuels due to treefall in Grey and Old-MPB stages significantly increased surface fireline intensities, facilitating active crown fire at lower wind speeds (>30–55 km/hr) across all moisture scenarios. Not accounting for low foliar moistures in Red and Grey stages, and large surface fuels in Grey and Old-MPB stages, underestimates the occurrence of active crown fire. Under extreme burning conditions, minimum wind speeds for active crown fire were 25–35 km/hr lower for Red, Grey and Old-MPB stands compared to Green. However, if transition to crown fire occurs (outside the stand, or within the stand via ladder fuels or wind gusts >65 km/hr), active crown fire would be sustained at similar wind speeds, suggesting observed fire behavior may not be qualitatively different among MPB stages under extreme burning conditions. Overall, the risk (probability) of active crown fire appears elevated in MPB-affected stands, but the predominant fire hazard (crown fire) is similar across MPB stages and is characteristic of lodgepole pine forests where extremely dry, gusty weather conditions are key factors in determining fire behavior. PMID:22272268

  1. In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns.

    PubMed

    Rosentritt, Martin; Hahnel, Sebastian; Engelhardt, Frank; Behr, Michael; Preis, Verena

    2017-05-01

    The aim of this study is to investigate the performance and fracture resistance of different CAD/CAM ceramic and composite materials as implant- or tooth-supported single crowns with respect to the clinical procedure (screwed/bonded restoration). One hundred twenty crowns were fabricated on implants or human molar teeth simulating (a) chairside procedure ([CHAIR] implant crown bonded to abutment), (b) labside procedure ([LAB] abutment and implant crown bonded in laboratory, screwed chairside), and (c) reference ([TOOTH] crowns luted on human teeth). Four materials were investigated: ZLS (zirconia-reinforced lithium silicate ceramic; Celtra Duo, Degudent: polished (P)/crystallized (C)), RB (resin-based composite; Cerasmart, GC), and RIC (resin-infiltrated ceramic; Enamic, Vita-Zahnfabrik). LiS (lithiumdisilicate; Emax CAD, Ivoclar-Vivadent) served as reference. Combined thermal cycling and mechanical loading (TCML) was performed simulating a 5-year clinical situation. Fracture force was determined. Data were statistically analyzed (Kolmogorov-Smirnov test, one-way ANOVA; post hoc Bonferroni, α = 0.05). One crown of ZLS_C[LAB] (1,200,000 cycles) and RB[CHAIR] (890 cycles) failed during TCML. Fracture values varied between 977.7 N(RB) and 3070.4 N(LiS)[CHAIR], 1130.6 N(RB) and 2998.1 N(LiS)[LAB], and 1802.4 N(ZLS) and 2664.3 N(LiS)[TOOTH]. Significantly (p < 0.003) different forces were found between the materials in all three groups. ZLS_C, RIC, and RB showed significantly (p < 0.014) different values for the individual groups. Partly ceramic and resin-based materials performed differently on implant or tooth abutments. The insertion of a screw channel reduced the stability for individual crown materials. Insertion of the screw channel should be performed carefully. All restorations were in a range where clinical application seems not restricted, but insertion of a screw channel might reduce stability of individual materials.

  2. Vertical stratification of the nutritional value of fruit: macronutrients and condensed tannins.

    PubMed

    Houle, Alain; Conklin-Brittain, Nancy L; Wrangham, Richard W

    2014-12-01

    Competing successfully for the best feeding sites is an important behavioral strategy but little is known about how feeding sites vary nutritionally within a fruit tree. To answer this question we tested how the nutritional value of a fruit is influenced by its ripeness and its height within the tree crown. A complementary objective was to assess the nutritional value of the midripe fruit, a food item rarely mentioned in the literature despite being exploited on a daily basis by many frugivores. We measured how the dry weight of pulp, water content, and concentration of macronutrients and condensed tannins varied within the tree crowns of 15 fruit species. Collections occurred early in the fruiting cycle, so as to assess the amount of food in the tree before its exploitation by primates. We found that (1) the upper crown produced fruit densities 4.2 times higher, and a fruit crop 4.8 times larger, than the lower crown of the same tree; (2) considering only midripe and ripe stages, upper-crown fruits contained 28.6% more dry pulp, 21.1% more water, and 13.5% more sugars per dry matter than lower-crown fruits of the same tree; (3) midripe fruits contained 80% of the concentrations of sugars of ripe fruits, making them a sweeter food item than one would expect from the intermediate color of their epidermis; (4) cellulose, hemicellulose, proteins, and ash proportionally decreased in concentration while dry pulp and sugars increased during ripening; and (5) ripe fruits were usually rare in the tree (<0.5% of all fruit available) compared to midripe fruits (3-8%). Overall, upper-crown feeding sites produced a higher density and quality of food than lower-crown sites of the same tree. Our data therefore provide a clear nutritional explanation for why tree-feeding frugivores compete for the highest feeding sites. © 2014 Wiley Periodicals, Inc.

  3. Failure analysis of various monolithic posterior aesthetic dental crowns using finite element method

    NASA Astrophysics Data System (ADS)

    Porojan, Liliana; Topală, Florin

    2017-08-01

    The aim of the study was to assess the effect of material stiffness and load on the biomechanical performance of the monolithic full-coverage posterior aesthetic dental crowns using finite element analysis. Three restorative materials for monolithic dental crowns were selected for the study: zirconia; lithium disilicate glass-ceramic, and resin-based composite. Stresses were calculated in the crowns for all materials and in the teeth structures, under different load values. The experiments show that dental crowns made from all this new aesthetic materials processed by CAD/CAM technologies would be indicated as monolithic dental crowns for posterior areas.

  4. Experimental and numerical study on the strength of all-ceramic crowns

    NASA Astrophysics Data System (ADS)

    Lu, Chenglin; Zhang, Xiuyin; Zhang, Dongsheng

    2008-11-01

    Two types of sectioned tooth-like ceramic crowns (IPS Empress 2) were prepared along lingual-facial direction and the fracture process of crowns under contact load was directly monitored with the use of imaging system. The displacement filed resulted from digital image correlation indicate that the fracture mode of real crown is more complicated while the flat crown has the same rupture mode as described by other investigators. Meanwhile numerical simulation was also carried out to support the experiments. Stress distributions in individual layer and interface were presented. Results indicate that the presented experimental and numerical methods are efficient in studying the fracture mechanism of all-ceramic crowns.

  5. Method and apparatus for controlling an earthworking implement to preserve a crown on a road surface

    NASA Technical Reports Server (NTRS)

    Lundquist, Steve D. (Inventor); Staub, Michael D. (Inventor); Alster, Louis G. (Inventor)

    1999-01-01

    A method and apparatus for controlling an earthworking implement on an earthworking machine to preserve a crown on the surface of a road, including determining the position of the crown on the road surface, choosing a sloped grade on one side of the crown, positioning the earthworking implement on the sloped grade so that a first end of the earthworking implement is on the road surface. The processor determines a desired position of a second end of the earthworking implement so that the second end overlaps the crown and the earthworking implement does not cut the crown.

  6. Fracture-resistant monolithic dental crowns.

    PubMed

    Zhang, Yu; Mai, Zhisong; Barani, Amir; Bush, Mark; Lawn, Brian

    2016-03-01

    To quantify the splitting resistance of monolithic zirconia, lithium disilicate and nanoparticle-composite dental crowns. Fracture experiments were conducted on anatomically-correct monolithic crown structures cemented to standard dental composite dies, by axial loading of a hard sphere placed between the cusps. The structures were observed in situ during fracture testing, and critical loads to split the structures were measured. Extended finite element modeling (XFEM), with provision for step-by-step extension of embedded cracks, was employed to simulate full failure evolution. Experimental measurements and XFEM predictions were self-consistent within data scatter. In conjunction with a fracture mechanics equation for critical splitting load, the data were used to predict load-sustaining capacity for crowns on actual dentin substrates and for loading with a sphere of different size. Stages of crack propagation within the crown and support substrate were quantified. Zirconia crowns showed the highest fracture loads, lithium disilicate intermediate, and dental nanocomposite lowest. Dental nanocomposite crowns have comparable fracture resistance to natural enamel. The results confirm that monolithic crowns are able to sustain high bite forces. The analysis indicates what material and geometrical properties are important in optimizing crown performance and longevity. Copyright © 2015 Academy of Dental Materials. All rights reserved.

  7. Evaluation of the occlusal contact of crowns fabricated with the bite impression method.

    PubMed

    Makino, Sachi; Okada, Daizo; Shin, Chiharu; Ogura, Reiko; Ikeda, Masaomi; Miura, Hiroyuki

    2013-09-30

    In prosthodontic treatment, reconstruction of a proper occlusal contact relationship is very important as well as reconstruction of a proper interproximal relationship and marginal fitness. Unfortunately, occlusal relationships are sometimes lost in the process of occlusal adjustment of crowns. The purpose of this study was to compare the occlusal contacts of single crown fabricated by two different types of impression techniques. Nine subjects, whose molars required treatment with crown restoration, were enrolled in this study. Full cast crowns were fabricated using two types of impression techniques: the conventional impression method (CIM) and the bite impression method (BIM). The occlusal contacts of crowns were precisely evaluated at the following stages: after occlusal adjustment on the articulator (Step 0), before occlusal adjustment in the mouth (Step 1), after occlusal adjustment at the intercuspal position (Step 2), and after occlusal adjustment during lateral and protrusive excursions (Step 3). The number of occlusal contacts of the crowns on the functional cusps fabricated with BIM was significantly greater than that with CIM after occlusal adjustment. For this reason, the crowns fabricated with BIM might have a more functionally desirable occlusal surface compared to the crowns fabricated with CIM.

  8. FRACTURE-RESISTANT MONOLITHIC DENTAL CROWNS

    PubMed Central

    Zhang, Yu; Mai, Zhisong; Barani, Amir; Bush, Mark; Lawn, Brian

    2016-01-01

    Objective To quantify the splitting resistance of monolithic zirconia, lithium disilicate and nanoparticle-composite dental crowns. Methods Fracture experiments were conducted on anatomically-correct monolithic crown structures cemented to standard dental composite dies, by axial loading of a hard sphere placed between the cusps. The structures were observed in situ during fracture testing, and critical loads to split the structures were measured. Extended finite element modeling (XFEM), with provision for step-by-step extension of embedded cracks, was employed to simulate full failure evolution. Results Experimental measurements and XFEM predictions were self consistent within data scatter. In conjunction with a fracture mechanics equation for critical splitting load, the data were used to predict load-sustaining capacity for crowns on actual dentin substrates and for loading with a sphere of different size. Stages of crack propagation within the crown and support substrate were quantified. Zirconia crowns showed the highest fracture loads, lithium disilicate intermediate, and dental nanocomposite lowest. Dental nanocomposite crowns have comparable fracture resistance to natural enamel. Significance The results confirm that monolithic crowns are able to sustain high bite forces. The analysis indicates what material and geometrical properties are important in optimizing crown performance and longevity. PMID:26792623

  9. A Comparison of Marginal Gaps of All-Ceramic Crowns Constructed from Scanned Impressions and Models.

    PubMed

    Tabesh, Raena; Dudley, James

    This study compared the marginal gaps of computer-aided design/computer-aided manufacture (CAD/CAM)-fabricated all-ceramic crowns constructed from scanned impressions and models and with two different occlusal reduction designs. Two typodont mandibular first molars were prepared to receive CAD/CAM-fabricated all-ceramic crowns. Both molars were prepared to ideal crown reduction, the first with anatomical occlusal reduction (AOR) and the second with completely flat occlusal reduction (FOR). Nine polyvinyl siloxane impressions (PVS) were taken, and nine stone replicas fabricated for each preparation. All impressions and stone models were scanned using a laser scanner (Planmeca Planscan, E4D technologies), and 36 lithium disilicate (IPS e.max CAD) crowns were milled. The marginal gap was measured in four locations using a light stereomicroscope. Crowns constructed from preparations with both occlusal reduction designs demonstrated similar marginal gaps (FOR = 97.98; AOR = 89.12; P = .739). However, all crowns constructed from scanned impressions presented significantly larger marginal gaps than the crowns fabricated from scanned models (impressions = 109.26; models = 77.84; P = .002). Scanning stone models produced all-ceramic crowns with significantly smaller marginal gaps than scanning impressions, irrespective of the occlusal reduction design.

  10. In-cylinder flows of a motored four-stroke engine with flat-crown and slightly concave-crown pistons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, R.F.; Yang, H.S.; Yeh, C.-N.

    2008-04-15

    The temporal and spatial evolution processes of the in-cylinder flow structures and turbulence intensities in the symmetry and offset planes of a motored four-valve, four-stroke engine during the intake and compression strokes are diagnosed by using a particle image velocimeter. Two pistons of different crown shapes (flat-crown and slightly concave-crown pistons) are studied. The inception, establishment, and evolution of the tumbling vortical flow structures during the intake and compression strokes are clearly depicted. Quantitative strengths of the rotating vortical flow motions are presented by a dimensionless parameter, the tumble ratio, which can represent the mean angular velocity of the vorticesmore » in the target plane. The turbulence intensity of the in-cylinder flow is also calculated by using the measured time-varying velocity data. The results show that the flat-crown piston induces higher bulk-averaged tumble ratio and turbulence intensity than the slightly concave-crown piston does because the tumble ratio and turbulence generated by the flat-crown piston in the offset planes during the compression stroke are particularly large. The engine with the flat-crown piston also presents larger torque and power outputs and lower hydrocarbon emission than that with the slightly concave-crown piston. This might be caused by the enhanced combustion in the engine cylinder due to the stronger tumble ratio and turbulence intensity. (author)« less

  11. Holographic evaluation of the marginal fit of complete crowns loaded at central fossa

    NASA Astrophysics Data System (ADS)

    Chen, Terry Y.; Chang, Guan L.; Wu, Shih H.

    1993-07-01

    In dentistry, the defect of cementation on the margins of crowns accumulates bacterial plaque easily. This can result in recurrent caries and periodontal disease. In this paper holographic interferometry is applied to study the effect of masticatory force on various complete crowns. Four complete molar crowns made from different casting materials (Au, Pd-Ag, Ni-Cr, and PFM) were tested. The horizontal displacements of two points near the margin, measured by the method of multiple observations, could be as large as 15 micrometers under normal load (25 kgw). However, the marginal discrepancy of all four crowns estimated were quite small (< 0.2 micrometers ). This also indicates that the cementation between the crown and the tooth is quite good. Nevertheless, when the load was increased to 45 kgw, a defect of cementation was found on the Pd-Ag crown.

  12. Simplified cementation of lithium disilicate crowns: Retention with various adhesive resin cement combinations.

    PubMed

    Johnson, Glen H; Lepe, Xavier; Patterson, Amanda; Schäfer, Oliver

    2017-09-27

    A composite resin cement and matching self-etch adhesive was developed to simplify the dependable retention of lithium disilicate crowns. The efficacy of this new system is unknown. The purpose of this in vitro study was to determine whether lithium disilicate crowns cemented with a new composite resin and adhesive system and 2 other popular systems provide clinically acceptable crown retention after long-term aging with monthly thermocycling. Extracted human molars were prepared with a flat occlusal surface, 20-degree convergence, and 4 mm axial length. The axio-occlusal line angle was slightly rounded. The preparation surface area was determined by optical scanning and the analysis of the standard tessellation language (STL) files. The specimens were distributed into 3 cement groups (n=12) to obtain equal mean surface areas. Lithium disilicate crowns (IPS e.max Press) were fabricated for each preparation, etched with 9.5% hydrofluoric acid for 15 seconds, and cleaned. Cement systems were RelyX Ultimate with Scotch Bond Universal (3M Dental Products); Monobond S, Multilink Automix with Multilink Primer A and B (Ivoclar Vivadent AG); and NX3 Nexus with OptiBond XTR (Kerr Corp). Each adhesive provided self-etching of the dentin. Before cementation, the prepared specimens were stored in 35°C water. A force of 196 N was used to cement the crowns, and the specimens were polymerized in a 35°C oven at 100% humidity. After 24 hours of storage at 100% humidity, the cemented crowns were thermocycled (5°C to 55°C) for 5000 cycles each month for 6 months. The crowns were removed axially at 0.5 mm/min. The removal force was recorded and the dislodgement stress calculated using the preparation surface area. The type of cement failure was recorded, and the data were analyzed by 1-way ANOVA and the chi-square test (α=.05) after the equality of variances had been assessed with the Levene test. The Levene test was nonsignificant (P=.936). The ANOVA revealed the mean removal stresses, and forces did not differ for RelyX Ultimate with Scotchbond Universal (3.9 MPa; 522 N) and Multilink Automix with Multilink Primer (3.7 MPa; 511 N); both differed significantly (P=.022) from the mean for NX3 Nexus with OptiBond XTR (2.9 MPa; 387 N). For all 3 cements, the modes of failure showed cement principally on the crown intaglio, and the chi-square analysis was nonsignificant (P=.601). IPS e.max Press (lithium disilicate) crowns were well retained (2.9-3.9 MPa; 387-522 N) by the 3 cement-adhesive combinations after 6 months of aging with monthly thermocycling. These results can serve as a basis for cement selection for this type of crown because the values significantly exceeded those for zinc phosphate. Cements using their matched dentin bonding agent as the ceramic primer were as successful as cements with a separate silane coupling agent. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. 50 CFR 21.44 - Depredation order for horned larks, house finches, and white-crowned sparrows in California.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... finches, and white-crowned sparrows in California. 21.44 Section 21.44 Wildlife and Fisheries UNITED... larks, house finches, and white-crowned sparrows in California. Horned larks (Eremophila alpestris), house finches (Carpodacus mexicanus), and white-crowned sparrows (Zonotrichia leucophrys) may be taken...

  14. Chapter 7 - Crown condition

    Treesearch

    KaDonna C. Randolph

    2018-01-01

    Tree crown conditions are visually assessed by the U.S. Department of Agriculture, Forest Service, Forest Inventory and Analysis (FIA) Program as an indicator of forest health. These assessments are useful because individual tree photosynthetic capacity is dependent upon the size and condition of the crown. In general, trees with full, vigorous crowns are associated...

  15. D.b.h./crown diameter relationships in mixed Appalachian hardwood stands

    Treesearch

    Neil I. Lamson; Neil I. Lamson

    1987-01-01

    Linear regression formulae for predicting crown diameter as a function of stem diameter are presented for nine species found in 50- to 80-year-old mixed hardwood stands in north-central West Virginia. Generally, crown diameter was closely related to tolerance; more tolerant species had larger crowns.

  16. Enhancing fatigue life of cylinder-crown integrated structure by optimizing dimension

    NASA Astrophysics Data System (ADS)

    Zhang, Weiwei; Wang, Xiaosong; Wang, Zhongren; Yuan, Shijian

    2015-03-01

    Cylinder-crown integrated hydraulic press (CCIHP) is a new press structure. The hemispherical hydraulic cylinder also functions as a main portion of crown, which has lower weight and higher section modulus compared with the conventional hydraulic cylinder and press crown. As a result, the material strength capacity is better utilized. During the engineering design of cylinder-crown integrated structure, in order to increase the fatigue life, structural optimization on the basis of the adaptive macro genetic algorithms (AMGA) is first conducted to both reduce weight and decrease peak stress. It is shown that the magnitude of the maximum principal stress is decreased by 28.6%, and simultaneously the total weight is reduced by 4.4%. Subsequently, strain-controlled fatigue test is carried out, and the stress-strain hysteresis loops and cyclic hardening curve are obtained. Based on linear fit, the fatigue properties are calculated and used for the fatigue life prediction. It is shown that the predicted fatigue life is significantly increased from 157000 to 1070000 cycles after structural optimization. Finally, according to the optimization design, a 6300 kN CCIHP has been manufactured, and priority application has been also suggested.

  17. Biomechanical properties of polymer-infiltrated ceramic crowns on one-piece zirconia implants after long-term chewing simulation.

    PubMed

    Baumgart, Pia; Kirsten, Holger; Haak, Rainer; Olms, Constanze

    2018-05-23

    Implant and superstructure provide a complex system, which has to withstand oral conditions. Concerning the brittleness of many ceramics, fractures are a greatly feared issue. Therefore, polymer-infiltrated ceramic networks (PICNs) were developed. Because of its low Young's modulus and high elastic modulus, the PICN crown on a one-piece zirconia implant might absorb forces to prevent the system from fracturing in order to sustain oral forces. Recommendations for the material of superstructure on zirconia implants are lacking, and only one study investigates PICN crowns on these types of implants. Accordingly, this study aimed to examine PICN crowns on one-piece zirconia implants regarding bond strength and surface wear after long-term chewing simulation (CS). Twenty-five hybrid ceramic crowns (Vita Enamic, Vita Zahnfabrik) were produced using computer-aided design/computer-aided manufacturing (CAD/CAM) technology and adhesively bonded (RelyX™ Ultimate, 3M ESPE) to zirconia implants. Twenty of the specimens underwent simultaneous mechanical loading and thermocycling simulating a 5-year clinical situation (SD Mechatronik GmbH). Wear depth and wear volume, based on X-ray micro-computed tomography volume scans (Skyscan 1172-100-50, Bruker) before and after CS, were evaluated. All crowns were removed from the implants using a universal testing machine (Z010, Zwick GmbH&Co.KG). Subsequently, luting agent was light microscopically localized (Stemi 2000-C, Zeiss). With a scanning electron microscope (SEM, Phenom™ G2 pro, Phenom World), the area of abrasion was assessed. 1. After CS, none of the tested crowns were fractured or loosened. 2. The maximum vertical wear after CS was M = 0.31 ± 0.04 mm (mean ± standard deviation), and the surface wear was M = 0.74 ± 0.23 mm 3 . 3. The pull-off tests revealed a 1.8 times higher bond strength of the control group compared to the experimental group (t(23) = 8.69, p < 0.001). 4. Luting agent was mostly located in the crowns, not on the implants. 5. The area of abrasion showed avulsion and a rough surface. PICN on one-piece zirconia implants showed high bond strength and high wear after CS.

  18. [Clinical application of IPS-empress 2 pressable all-ceramic crowns].

    PubMed

    Wang, Ai-jun; He, Xiao-ming; Liu, Li-xia; Zhang, Chao-biao; Zhang, Min; Shen, Bei-yong

    2007-02-01

    To evaluate the clinical prosthetic effect of IPS-Empress 2 pressahie ceramic crowns. 198 teeth of 70 patients were restored with IPS-Empress 2 pressahie ceramic crowns. The patients were asked to return in one week and every half year. The clinical prosthetic effect was evaluated. Through follow-up of 3-38 months, the veneer porcelain crowns of 3 teeth were broken. 2 crowns fall off due to teeth fracture, gingivitis occurred in 2 teeth, pulpitis or periapical periodontitis occurred in 3 teeth. The shades of 3 crowns were darkening. The prosthetic effect of 185 teeth was satisfied. The rate of satisfaction was 93.4%. IPS-Empress 2 pressable all-ceramic crown has the advantages of aesthetic effect, good hiocompatihility and simple fabrication. But its strength is not enough for posterior teeth and it can not cover the deep color of non-vital teeth and metal materials.

  19. Optical Sensing of Aromatic Amino Acids and Dipeptides by a Crown-Ether-Functionalized Perylene Bisimide Fluorophore.

    PubMed

    Weißenstein, Annike; Saha-Möller, Chantu R; Würthner, Frank

    2018-06-04

    The host-guest binding properties of a fluorescent perylene bisimide (PBI) receptor equipped with crown ether were studied in detail with a series of aromatic amino acids and dipeptides by UV/Vis, fluorescence and NMR spectroscopy. Fluorescence titration experiments showed that electron-rich aromatic amino acids and dipeptides strongly quench the fluorescence of the electron-poor PBI host molecule. Benesi-Hildebrand plots of fluorescence titration data confirmed the formation of host-guest complexes with 1:2 stoichiometry. Binding constants determined by global analysis of UV/Vis and fluorescence titration experiments revealed values between 10 3  m -1 and 10 5  m -1 in acetonitrile/methanol (9:1) at 23 °C. These data showed that amino acid l-Trp having an indole group and dipeptides containing this amino acid bind to the PBI receptor more strongly than other amino acids and dipeptides investigated here. For dipeptides containing l-Trp or l-Tyr, the binding strength is dependent on the distance between the ammonium group and the aromatic unit of the amino acids and dipeptides leading to a strong sensitivity for Ala-Trp dipeptide. 1D and 2D NMR experiments also corroborated 1:2 host-guest complexation and indicated formation of two diastereomeric species of host-guest complexes. The studies have shown that a properly functionalized PBI fluorophore functions as a molecular probe for the optical sensing of aromatic amino acids and dipeptides. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Dental senescence in a long-lived primate links infant survival to rainfall

    PubMed Central

    King, Stephen J.; Arrigo-Nelson, Summer J.; Pochron, Sharon T.; Semprebon, Gina M.; Godfrey, Laurie R.; Wright, Patricia C.; Jernvall, Jukka

    2005-01-01

    Primates tend to be long-lived, and, except for humans, most primate females are able to reproduce into old age. Although aging in most mammals is accompanied by dental senescence due to advanced wear, primates have low-crowned teeth that wear down before old age. Because tooth wear alters crown features gradually, testing whether early dental senescence causes reproductive senescence has been difficult. To identify whether and when low-crowned teeth compromise reproductive success, we used a 20-year field study of Propithecus edwardsi, a rainforest lemur from Madagascar with a maximum lifespan of >27 years. We analyzed tooth wear in three dimensions with dental topographic analysis by using Geographical Information Systems (GIS) technology. We report that tooth wear exposes compensatory shearing blades that maintain dental function for 18 years. Beyond this age, female fertility remains high; however infants survive only if lactation seasons have elevated rainfall. Therefore, low-crowned teeth accommodate wear to a point, after which reproductive success closely tracks environmental fluctuations. These results suggest a tooth wear-determined, but rainfall-mediated, onset of reproductive senescence. Additionally, our study indicates that even subtle changes in climate may affect reproductive success of rainforest species. PMID:16260727

  1. Solid phase extraction of amoxicillin using dibenzo-18-crown-6 modified magnetic-multiwalled carbon nanotubes prior to its spectrophotometric determination.

    PubMed

    Ahmadi, Mazaher; Madrakian, Tayyebeh; Afkhami, Abbas

    2016-01-01

    This work reports on a method for selective extraction and sensitive determination of amoxicillin drug (AMX). The method is based on solid phase extraction of AMX by a novel modified magnetic nanoadsorbent prior to spectrophotometric determination of AMX using a procedure based on formation a colored azo-derivative of the investigated drug. The nanoadsorbent has been synthesized by modification of magnetic-multiwalled carbon nanotube with dibenzo-18-crown-6 moieties. The synthesized nanoparticles were characterized using TEM, XRD and FT-IR measurements. At the next step, various factors that could potentially affect adsorption and desorption efficiencies of AMX, have been optimized. The results showed that under the optimized conditions, sensitive and selective determination of the investigated drug in concentration range of 5.0-1000.0 ng mL(-1) with the limit of detection of 3.0 ng mL(-1) was achievable. Furthermore, the real sample analysis (i.e. amoxicillin capsules and human urine samples) results indicated that a reliable promising candidate method has been developed for the determination of AMX in the investigated real samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. 21 CFR 872.3770 - Temporary crown and bridge resin.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Temporary crown and bridge resin. 872.3770 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3770 Temporary crown and bridge resin. (a) Identification. A temporary crown and bridge resin is a device composed of a material, such as...

  3. Evaluation of sampling strategies to estimate crown biomass

    Treesearch

    Krishna P Poudel; Hailemariam Temesgen; Andrew N Gray

    2015-01-01

    Depending on tree and site characteristics crown biomass accounts for a significant portion of the total aboveground biomass in the tree. Crown biomass estimation is useful for different purposes including evaluating the economic feasibility of crown utilization for energy production or forest products, fuel load assessments and fire management strategies, and wildfire...

  4. 76 FR 40354 - Notice of Cancellation of Environmental Impact Statement for the Proposed Crowned Ridge Wind...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-08

    ... Environmental Impact Statement for the Proposed Crowned Ridge Wind Energy Center Project, Codington and Grant... to design, construct, operate, and maintain a 150-megawatt Crowned Ridge Wind Energy Center Project... that memorandum, I have terminated the NEPA process for NextEra's proposed Crowned Ridge Wind Energy...

  5. Experimental modeling of crown fire initiation in open and closed shrubland systems

    Treesearch

    W. Tachajapong; S. Lozano; S. Mahalingam; D.R. Weise

    2014-01-01

    The transition of surface fire to live shrub crown fuels was studied through a simplified laboratory experiment using an open-topped wind tunnel. Respective surface and crown fuels used were excelsior (shredded Populus tremuloides wood) and live chamise (Adenostoma fasciculatum, including branches and foliage). A high crown fuel...

  6. 78 FR 63559 - Order of Suspension of Trading; In The Matter of Crown Alliance Capital Limited

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-24

    ... Alliance Capital Limited (``Crown Alliance''), quoted under the ticker symbol CACL, because of questions regarding the accuracy of assertions in Crown Alliance's public filings concerning the company's assets and... of Crown Alliance Capital Limited October 22, 2013. It appears to the Securities and Exchange...

  7. Evaluation of wild juglans species for crown gall resistance

    USDA-ARS?s Scientific Manuscript database

    A. tumefaciens is a soil-borne Gram-negative bacterium which causes crown gall on many dicotyledonous plant species including walnut. Crown gall symptoms on walnut are characterized by large tumors located near the crown of the tree but can occur near wounds caused by bleeding cuts or at the graft u...

  8. 21 CFR 872.3770 - Temporary crown and bridge resin.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Temporary crown and bridge resin. 872.3770 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3770 Temporary crown and bridge resin. (a) Identification. A temporary crown and bridge resin is a device composed of a material, such as...

  9. Digital evaluation of the fit of zirconia-reinforced lithium silicate crowns with a new three-dimensional approach.

    PubMed

    Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis

    2017-11-30

    Several methods for the evaluation of fit of computer-aided design/computer-assisted manufacture (CAD/CAM)-fabricated restorations have been described. In the study, digital models were recorded with an intraoral scanning device and were measured using a new three-dimensional (3D) computer technique to evaluate restoration internal fit. The aim of the study was to evaluate the internal adaptation and fit of chairside CAD/CAM-fabricated zirconia-reinforced lithium silicate ceramic crowns fabricated with different post-milling protocols. The null hypothesis was that different post-milling protocols did not influence the fitting accuracy of zirconia-reinforced lithium silicate restorations. A master all-ceramic crown preparation was completed on a maxillary right first molar on a typodont. Twenty zirconia-reinforced lithium silicate ceramic crowns (Celtra Duo, Dentsply Sirona) were designed and milled using a chairside CAD/CAM system (CEREC Omnicam, Dentsply Sirona). The 20 crowns were randomly divided into two groups based on post-milling protocols: no manipulation after milling (Group MI) and oven fired-glazing after milling (Group FG). A 3D computer method was used to evaluate the internal adaptation of the crowns. This was based on a subtractive analysis of a digital scan of the crown preparation and a digital scan of the thickness of the cement space over the crown preparation as recorded by a polyvinylsiloxane (PVS) impression material. The preparation scan and PVS scan were matched in 3D and a 3D difference analysis was performed with a software program (OraCheck, Cyfex). Three areas of internal adaptation and fit were selected for analysis: margin (MA), axial wall (AX), and occlusal surface (OC). Statistical analysis was performed using 80% percentile and one-way ANOVA with post-hoc Scheffé test (P = .05). The closest internal adaptation of the crowns was measured at the axial wall with 102.0 ± 11.7 µm for group MI-AX and 106.3 ± 29.3 µm for group FG-AX. The largest internal adaptation of the crowns was measured for the occlusal surface with 258.9 ± 39.2 µm for group MI-OC and 260.6 ± 55.0 µm for group FG-OC. No statistically significant differences were found for the post-milling protocols (P > .05). The 3D difference pattern was visually analyzed for each area with a color-coded scheme. Post-milling processing did not affect the internal adaptation of zirconia-reinforced lithium silicate crowns fabricated with a chairside CAD/CAM technique. The new 3D computer technique for the evaluation of fit of restorations may be highly promising and has the opportunity to be applied to clinical studies.

  10. A comparison of marginal fit between press-fabricated and CAD/CAM lithium disilicate crowns.

    PubMed

    Carlile, Richard S; Owens, Wade H; Greenwood, William J; Guevara, Peter H

    2018-01-01

    The purpose of this study was to compare the marginal fit of press-fabricated lithium disilicate crowns with that of computer-aided design/computer-aided manufacturing (CAD/CAM) lithium disilicate crowns to determine if the fabrication method has an influence on marginal fit. The marginal fit of 25 pressed and 25 CAD/CAM crowns was measured using the replica technique. The sites measured were the mesial, distal, facial, and lingual margins. A microscope at 10× magnification was used to obtain the measurements. Each site was measured 4 times, and intraclass correlation coefficients were used to assess measurement errors. An unpaired t test was used to evaluate the differences between the 2 groups. Mean marginal gap measurements were greater for CAD/CAM crowns than for pressed crowns at all sites. Only the difference in mean gap at the facial margin was statistically significant (P < 0.001). Press-fabricated lithium disilicate crowns provided a better marginal fit than those fabricated by CAD/CAM, but both fabrication methods provided crowns with a clinically acceptable marginal fit.

  11. Comparison of Amount of Primary Tooth Reduction Required for Anterior and Posterior Zirconia and Stainless Steel Crowns.

    PubMed

    Clark, Larkin; Wells, Martha H; Harris, Edward F; Lou, Jennifer

    2016-01-01

    To determine if aggressiveness of primary tooth preparation varied among different brands of zirconia and stainless steel (SSC) crowns. One hundred primary typodont teeth were divided into five groups (10 posterior and 10 anterior) and assigned to: Cheng Crowns (CC); EZ Pedo (EZP); Kinder Krowns (KKZ); NuSmile (NSZ); and SSC. Teeth were prepared, and assigned crowns were fitted. Teeth were weighed prior to and after preparation. Weight changes served as a surrogate measure of tooth reduction. Analysis of variance showed a significant difference in tooth reduction among brand/type for both the anterior and posterior. Tukey's honest significant difference test (HSD), when applied to anterior data, revealed that SSCs required significantly less tooth removal compared to the composite of the four zirconia brands, which showed no significant difference among them. Tukey's HSD test, applied to posterior data, revealed that CC required significantly greater removal of crown structure, while EZP, KKZ, and NSZ were statistically equivalent, and SSCs required significantly less removal. Zirconia crowns required more tooth reduction than stainless steel crowns for primary anterior and posterior teeth. Tooth reduction for anterior zirconia crowns was equivalent among brands. For posterior teeth, reduction for three brands (EZ Pedo, Kinder Krowns, NuSmile) did not differ, while Cheng Crowns required more reduction.

  12. Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns

    PubMed Central

    Esquivel-Upshaw, J.F.; Kim, M.J.; Hsu, S.M.; Abdulhameed, N.; Jenkins, R.; Neal, D.; Ren, F.; Clark, A.E.

    2018-01-01

    Objectives To test the hypothesis that there is no difference in the in vivo maximum wear of enamel opposing monolithic zirconia crowns, enamel opposing porcelain fused to metal crowns and enamel opposing enamel. Methods Thirty patients needing single crowns were randomized to receive either a monolithic zirconia or metal-ceramic crown. Two non-restored opposing teeth in the same quadrants were identified to serve as enamel controls. After cementation, quadrants were scanned for baseline data. Polyvinylsiloxane impressions were obtained and poured in white stone. Patients were recalled at six-months and one-year for re-impression. Stone models were scanned using a tabletop laserscanner to determine maximum wear. Statistical analysis was performed using Mann-Whitney U to determine any significant differences between the wear of enamel against zirconia and metal-ceramic crowns. Results Sixteen zirconia and 14 metal-ceramic crowns were delivered. There were no statistical differences in mean wear of crown types (p = 0.165); enamel antagonists (p = 0.235) and enamel controls (p = 0.843) after one year. Conclusion Monolithic zirconia exhibited comparable wear of enamel compared with metal-ceramic crowns and control enamel after one year. Significance This study is clinically significant because the use of polished monolithic zirconia demonstrated comparable wear of opposing enamel to metal-ceramic and enamel antagonists. PMID:29042241

  13. An in-vitro investigation of the accuracy of fit of Procera and Empress crowns.

    PubMed

    Fleming, Garry J R; Dobinson, Marie M; Landini, Gabriel; Harris, Jonathan J

    2005-09-01

    The current study aimed to investigate the accuracy of fit and the reproducibility of inner crown profile for two types of high strength ceramics, IPS Empress and Procera. Procera and Empress crowns with four different morphologies were cemented to dies using zinc phosphate dental cement. Vertical and horizontal sections were made through each of the crown/die preparations and images of the vertical sections were compared for curvature reproduction by alignment using image processing. Measurements were made on horizontal sections to determine cement layer thickness. Alignment of the crowns using image analysis identified quantifiable variations in the inner surface profile compared with the outer surface of the die. The largest differences occurred from the cusp tips to the occlusal adaptation area and differences in surface profile were less pronounced for Procera than Empress crowns. Marginal gap varied independently of ceramic or internal crown shape from 7-529 microm for Procera and 26-548 microm for Empress. IPS Empress has a superior ability to reproduce the inner surface profile of the crown morphologies investigated compared with Procera. The reduced reproduction of surface profile was associated with an increased cement thickness at the occlusal contact area that may inadvertently lead to failure of the crowns functional characteristics.

  14. A tree canopy height delineation method based on Morphological Reconstruction—Open Crown Decomposition

    NASA Astrophysics Data System (ADS)

    Liu, Q.; Jing, L.; Li, Y.; Tang, Y.; Li, H.; Lin, Q.

    2016-04-01

    For the purpose of forest management, high resolution LIDAR and optical remote sensing imageries are used for treetop detection, tree crown delineation, and classification. The purpose of this study is to develop a self-adjusted dominant scales calculation method and a new crown horizontal cutting method of tree canopy height model (CHM) to detect and delineate tree crowns from LIDAR, under the hypothesis that a treetop is radiometric or altitudinal maximum and tree crowns consist of multi-scale branches. The major concept of the method is to develop an automatic selecting strategy of feature scale on CHM, and a multi-scale morphological reconstruction-open crown decomposition (MRCD) to get morphological multi-scale features of CHM by: cutting CHM from treetop to the ground; analysing and refining the dominant multiple scales with differential horizontal profiles to get treetops; segmenting LiDAR CHM using watershed a segmentation approach marked with MRCD treetops. This method has solved the problems of false detection of CHM side-surface extracted by the traditional morphological opening canopy segment (MOCS) method. The novel MRCD delineates more accurate and quantitative multi-scale features of CHM, and enables more accurate detection and segmentation of treetops and crown. Besides, the MRCD method can also be extended to high optical remote sensing tree crown extraction. In an experiment on aerial LiDAR CHM of a forest of multi-scale tree crowns, the proposed method yielded high-quality tree crown maps.

  15. Torque loss of different abutment sizes before and after cyclic loading.

    PubMed

    Moris, Izabela Cristina; Faria, Adriana Cláudia; Ribeiro, Ricardo Faria; Rodrigues, Renata Cristina

    2015-01-01

    The aim of this study was to compare 3.8- and 4.8-mm abutments submitted to simulations of masticatory cycles to examine whether abutment diameter and cemented vs screw-retained crowns affect torque loss of the abutments and crowns. Forty implant/abutment sets were divided into the following groups (n = 10 in each group): (1) G4.8S included 4.8-mm abutment with screw-retained crown; (2) G4.8C included 4.8-mm abutment with cemented crown; (3) G3.8S included 3.8-mm abutment with screw-retained crown; and (4) G3.8C included 3.8-mm abutment with cemented crown. All abutments were tightened with torque values of 20 Ncm, and 10 Ncm for screw-retained crowns. Torque loss was measured before and after cycling loading (300,000 cycles). Torque loss of screw-retained crowns significantly increased after cycling in abutments of groups G3.8S (P ≤ .05) and G4.8S (P = .001). No difference was noted between the abutments before cycling (P = .735), but G3.8S abutments presented greater torque loss than the other groups after cycling (P = .008). Significant differences were noted in the abutment torque loss before and after cycling loading only for the G3.8C group (P ≤ .05). The abutment diameter affects torque loss of screw-retained crowns and leads to failure during the test; mechanical cycling increases torque loss of abutment screw and screw-retained crowns.

  16. Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.

    PubMed

    Lee, Wan-Sun; Lee, Du-Hyeong; Lee, Kyu-Bok

    2017-08-01

    This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) µm for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) µm, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

  17. Primary tooth size asymmetry in twins and singletons.

    PubMed

    Heikkinen, T; Harila, V; Ollikkala, A; Alvesalo, L

    2016-08-01

    To explore asymmetry values of antimeric deciduous tooth crown dimensions in three types of twins: monozygotic (MZ), dizygotic same-sex (DZ) and opposite-sex (OS) vs. single-born controls. Mesiodistal and labio-lingual crown dimensions of second deciduous molars and mesiodistal canine and first molar crown dimensions of 2159 children at 6-12 years of age were evaluated, originating from the US cross-sectional Collaborative Perinatal Study from the 1970s, including altogether MZ (n = 28), DZ same-sex (n = 33) and OS (n = 39) pairs. Single born (n = 1959) were used as controls. Dental casts were measured for comparison of variance relationships calculated from antimeric teeth, exhibiting fluctuating (FA), and directional (DA) asymmetry using anova. Significant differences appeared in MZ and OS girls in DA of deciduous canines, which gain size in the first and second trimester, and deciduous second molars, which finally stop crown growth during the early post-natal period. Significantly, increased FA values appeared for lower deciduous canines and second molars, indicating greatest environmental stress in OS girls, MZ girls and DZ boys. Twin girls had more fluctuating and directional crown asymmetry than twin boys, but in some dimensions, the twins were more symmetric than controls. Transmembrane hormonal influence between opposite-sex twins, and late gestational stress factors, caused by placental malfunction and/or monochorionicity, may be involved in asymmetric growth of antimers, during critical periods of crown size gain. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. A benchmark study for the crown-type splashing dynamics of one- and two-component droplet wall-film interactions

    NASA Astrophysics Data System (ADS)

    Geppert, A.; Terzis, A.; Lamanna, G.; Marengo, M.; Weigand, B.

    2017-12-01

    The present paper investigates experimentally the impact dynamics of crown-type splashing for miscible two- and one-component droplet wall-film interactions over a range of Weber numbers and dimensionless film thicknesses. The splashing outcome is parametrised in terms of a set of quantifiable parameters, such as crown height, top and base diameter, wall inclination, number of fingers, and secondary droplet properties. The results show that the outcome of a splashing event is not affected by the choice of similar or dissimilar fluids, provided the dimensionless film thickness is larger than 0.1. Below this threshold, distinctive features of two-component interactions appear, such as hole formation and crown bottom breakdown. The observation of different crown shapes (e.g. V-shaped, cylindrical, and truncated-cone) confirms that vorticity production induces changes in the crown wall inclination, thus affecting the evolution of the crown height and top diameter. The evolution of the crown base diameter, instead, is mainly dependent on the relative importance of liquid inertia and viscous losses in the wall-film. The maximum number of liquid fingers decreases with increasing wall, film thickness, due to the enhanced attenuation of the effect of surface properties on the fingering process. The formation of secondary droplets is also affected by changes in the crown wall inclination. In particular, for truncated-cone shapes the occurrence of crown rim contraction induces a large scatter in the secondary droplet properties. Consequently, empirical models for the maximum number and mean diameter of the secondary droplets are derived for V-shaped crowns, as observed for the hexadecane-Hyspin interactions.

  19. Individual tree crown delineation using localized contour tree method and airborne LiDAR data in coniferous forests

    NASA Astrophysics Data System (ADS)

    Wu, Bin; Yu, Bailang; Wu, Qiusheng; Huang, Yan; Chen, Zuoqi; Wu, Jianping

    2016-10-01

    Individual tree crown delineation is of great importance for forest inventory and management. The increasing availability of high-resolution airborne light detection and ranging (LiDAR) data makes it possible to delineate the crown structure of individual trees and deduce their geometric properties with high accuracy. In this study, we developed an automated segmentation method that is able to fully utilize high-resolution LiDAR data for detecting, extracting, and characterizing individual tree crowns with a multitude of geometric and topological properties. The proposed approach captures topological structure of forest and quantifies topological relationships of tree crowns by using a graph theory-based localized contour tree method, and finally segments individual tree crowns by analogy of recognizing hills from a topographic map. This approach consists of five key technical components: (1) derivation of canopy height model from airborne LiDAR data; (2) generation of contours based on the canopy height model; (3) extraction of hierarchical structures of tree crowns using the localized contour tree method; (4) delineation of individual tree crowns by segmenting hierarchical crown structure; and (5) calculation of geometric and topological properties of individual trees. We applied our new method to the Medicine Bow National Forest in the southwest of Laramie, Wyoming and the HJ Andrews Experimental Forest in the central portion of the Cascade Range of Oregon, U.S. The results reveal that the overall accuracy of individual tree crown delineation for the two study areas achieved 94.21% and 75.07%, respectively. Our method holds great potential for segmenting individual tree crowns under various forest conditions. Furthermore, the geometric and topological attributes derived from our method provide comprehensive and essential information for forest management.

  20. Fracture Resistance and Mode of Failure of Ceramic versus Titanium Implant Abutments and Single Implant-Supported Restorations.

    PubMed

    Sghaireen, Mohd G

    2015-06-01

    The material of choice for implant-supported restorations is affected by esthetic requirements and type of abutment. This study compares the fracture resistance of different types of implant abutments and implant-supported restorations and their mode of failure. Forty-five Oraltronics Pitt-Easy implants (Oraltronics Dental Implant Technology GmbH, Bremen, Germany) (4 mm diameter, 10 mm length) were embedded in clear autopolymerizing acrylic resin. The implants were randomly divided into three groups, A, B and C, of 15 implants each. In group A, titanium abutments and metal-ceramic crowns were used. In group B, zirconia ceramic abutments and In-Ceram Alumina crowns were used. In group C, zirconia ceramic abutments and IPS Empress Esthetic crowns were used. Specimens were tested to failure by applying load at 130° from horizontal plane using an Instron Universal Testing Machine. Subsequently, the mode of failure of each specimen was identified. Fracture resistance was significantly different between groups (p < .05). The highest fracture loads were associated with metal-ceramic crowns supported by titanium abutments (p = .000). IPS Empress crowns supported by zirconia abutments had the lowest fracture loads (p = .000). Fracture modes of metal-ceramic crowns supported by titanium abutments included screw fracture and screw bending. Fracture of both crown and abutment was the dominant mode of failure of In-Ceram/IPS Empress crowns supported by zirconia abutments. Metal-ceramic crowns supported by titanium abutments were more resistant to fracture than In-Ceram crowns supported by zirconia abutments, which in turn were more resistant to fracture than IPS Empress crowns supported by zirconia abutments. In addition, failure modes of restorations supported by zirconia abutments were more catastrophic than those for restorations supported by titanium abutments. © 2013 Wiley Periodicals, Inc.

  1. Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns

    PubMed Central

    Tulapornchai, Chantana; Mamani, Jatuphol; Kamchatphai, Wannaporn; Thongpun, Noparat

    2013-01-01

    PURPOSE The objective of this study was to determine the effect of the color of a background substructure on the overall color of a zirconia-based all-ceramic crown. MATERIALS AND METHODS Twenty one posterior zirconia crowns were made for twenty subjects. Seven premolar crowns and six molar crowns were cemented onto abutments with metal post and core in the first and second group. In the third group, eight molar crowns were cemented onto abutments with a prefabricated post and composite core build-up. The color measurements of all-ceramic crowns were made before try-in, before and after cementation. A repeated measure ANOVA was used for a statistical analysis of a color change of all-ceramic crowns at α=.05. Twenty four zirconia specimens, with different core thicknesses (0.4-1 mm) were also prepared to obtain the contrast ratio of zirconia materials after veneering. RESULTS L*, a*, and b* values of all-ceramic crowns cemented either on a metal cast post and core or on a prefabricated post did not show significant changes (P>.05). However, the slight color changes of zirconia crowns were detected and represented by ΔE*ab values, ranging from 1.2 to 3.1. The contrast ratios of zirconia specimens were 0.92-0.95 after veneering. CONCLUSION No significant differences were observed between the L*, a*, and b* values of zirconia crowns cemented either on a metal cast post and core or a prefabricated post and composite core. However, the color of a background substructure could affect the overall color of posterior zirconia restorations with clinically recommended core thickness according to ΔE*ab values. PMID:24049574

  2. Displacement of screw-retained single crowns into implants with conical internal connections.

    PubMed

    Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin A; Clelland, Nancy L

    2013-01-01

    Internal conical implant-abutment connections without platforms may lead to axial displacement of crowns during screw tightening. This displacement may affect proximal contacts, incisal edge position, or occlusion. This study aimed to measure the displacement of screw-retained single crowns into an implant in three dimensions during screw tightening by hand or via torque driver. A stereolithic acrylic resin cast was created using computed tomography data from a patient missing the maxillary right central incisor. A 4.0- × 11-mm implant was placed in the edentulous site. Five porcelain-fused-to-metal single crowns were made using "cast-to" abutments. Crowns were tried on the stereolithic model, representing the patient, and hand tightened. The spatial relationship of crowns to the model after hand tightening was determined using three-dimensional digital image correlation (3D DIC), an optical measurement technique. The crowns were then tightened using a torque driver to 20 Ncm and the relative crown positions were again recorded. Testing was repeated three times for each crown, and displacement of the crowns was compared between the hand-tightened and torqued states. Commercial image correlation software was used to analyze the data. Mean vertical and horizontal crown displacement values were calculated after torqueing. The interproximal contacts were evaluated before and after torquing using an 8-μm aluminum foil shim. There were vertical and horizontal differences in crown positions between hand tightening and torqueing. Although these were small in magnitude, detectable displacements occurred in both apical and facial directions. After hand tightening, the 8-μm shim could be dragged without tearing. However, after torque tightening, the interproximal contacts were too tight and the 8-μm shim could not be dragged without tearing. Differences between hand tightening and torque tightening should be taken into consideration during laboratory and clinical adjustments to prevent esthetic and functional complications.

  3. Fracture resistance of metal-free composite crowns-effects of fiber reinforcement, thermal cycling, and cementation technique.

    PubMed

    Lehmann, Franziska; Eickemeyer, Grit; Rammelsberg, Peter

    2004-09-01

    The improved mechanical properties of contemporary composites have resulted in their extensive use for the restoration of posterior teeth. However, the influence of fiber reinforcement, cementation technique, and physical stress on the fracture resistance of metal-free crowns is unknown. This in vitro study evaluated the effect of fiber reinforcement, physical stress, and cementation methods on the fracture resistance of posterior metal-free Sinfony crowns. Ninety-six extracted human third molars received a standardized tooth preparation: 0.5-mm chamfer preparation and occlusal reduction of 1.3 to 1.5 mm. Sinfony (nonreinforced crowns, n=48) and Sinfony-Vectris (reinforced crowns, n=48) crowns restoring original tooth contour were prepared. Twenty-four specimens of each crown type were cemented, using either glass ionomer cement (GIC) or resin cement. Thirty-two crowns (one third) were stored in humidity for 48 hours. Another third was exposed to 10,000 thermal cycles (TC) between 5 degrees C and 55 degrees C. The remaining third was treated with thermal cycling and mechanical loading (TCML), consisting of 1.2 million axial loads of 50 N. The artificial crowns were then vertically loaded with a steel sphere until failure occurred. Significant differences in fracture resistance (N) between experimental groups were assessed by nonparametric Mann-Whitney U-test (alpha=.05). Fifty percent of the Sinfony and Sinfony-Vectris crowns cemented with glass ionomer cement loosened after thermal cycling. Thermal cycling resulted in a significant reduction in the mean fracture resistance for Sinfony crowns cemented with GIC, from 2037 N to 1282 N (P=.004). Additional fatigue produced no further effects. Fiber reinforcement significantly increased fracture resistance, from 1555 N to 2326 N (P=.001). The minimal fracture resistance was above 600 N for all combinations of material, cement and loading. Fracture resistance of metal-free Sinfony crowns was significantly increased by fiber reinforcement. Adhesive cementation may be recommended to avoid cementation failure.

  4. The expression of light-related leaf functional traits depends on the location of individual leaves within the crown of isolated Olea europaea trees.

    PubMed

    Escribano-Rocafort, Adrián G; Ventre-Lespiaucq, Agustina B; Granado-Yela, Carlos; Rubio de Casas, Rafael; Delgado, Juan A; Balaguer, Luis

    2016-04-01

    The spatial arrangement and expression of foliar syndromes within tree crowns can reflect the coupling between crown form and function in a given environment. Isolated trees subjected to high irradiance and concomitant stress may adjust leaf phenotypes to cope with environmental gradients that are heterogeneous in space and time within the tree crown. The distinct expression of leaf phenotypes among crown positions could lead to complementary patterns in light interception at the crown scale. We quantified eight light-related leaf traits across 12 crown positions of ten isolated Olea europaea trees in the field. Specifically, we investigated whether the phenotypic expression of foliar traits differed among crown sectors and layers and five periods of the day from sunrise to sunset. We investigated the consequences in terms of the exposed area of the leaves at the tree scale during a single day. All traits differed among crown positions except the length-to-width ratio of the leaves. We found a strong complementarity in the patterns of the potential exposed area of the leaves among day periods as a result of a non-random distribution of leaf angles across the crown. Leaf exposure at the outer layer was below 60 % of the displayed surface, reaching maximum interception during morning periods. Daily interception increased towards the inner layer, achieving consecutive maximization from east to west positions within the crown, matching the sun's trajectory. The expression of leaf traits within isolated trees of O. europaea varies continuously through the crown in a gradient of leaf morphotypes and leaf angles depending on the exposure and location of individual leaves. The distribution of light-related traits within the crown and the complementarity in the potential exposure patterns of the leaves during the day challenges the assumption of low trait variability within individuals. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Crown-Level Tree Species Classification Using Integrated Airborne Hyperspectral and LIDAR Remote Sensing Data

    NASA Astrophysics Data System (ADS)

    Wang, Z.; Wu, J.; Wang, Y.; Kong, X.; Bao, H.; Ni, Y.; Ma, L.; Jin, J.

    2018-05-01

    Mapping tree species is essential for sustainable planning as well as to improve our understanding of the role of different trees as different ecological service. However, crown-level tree species automatic classification is a challenging task due to the spectral similarity among diversified tree species, fine-scale spatial variation, shadow, and underlying objects within a crown. Advanced remote sensing data such as airborne Light Detection and Ranging (LiDAR) and hyperspectral imagery offer a great potential opportunity to derive crown spectral, structure and canopy physiological information at the individual crown scale, which can be useful for mapping tree species. In this paper, an innovative approach was developed for tree species classification at the crown level. The method utilized LiDAR data for individual tree crown delineation and morphological structure extraction, and Compact Airborne Spectrographic Imager (CASI) hyperspectral imagery for pure crown-scale spectral extraction. Specifically, four steps were include: 1) A weighted mean filtering method was developed to improve the accuracy of the smoothed Canopy Height Model (CHM) derived from LiDAR data; 2) The marker-controlled watershed segmentation algorithm was, therefore, also employed to delineate the tree-level canopy from the CHM image in this study, and then individual tree height and tree crown were calculated according to the delineated crown; 3) Spectral features within 3 × 3 neighborhood regions centered on the treetops detected by the treetop detection algorithm were derived from the spectrally normalized CASI imagery; 4) The shape characteristics related to their crown diameters and heights were established, and different crown-level tree species were classified using the combination of spectral and shape characteristics. Analysis of results suggests that the developed classification strategy in this paper (OA = 85.12 %, Kc = 0.90) performed better than LiDAR-metrics method (OA = 79.86 %, Kc = 0.81) and spectral-metircs method (OA = 71.26, Kc = 0.69) in terms of classification accuracy, which indicated that the advanced method of data processing and sensitive feature selection are critical for improving the accuracy of crown-level tree species classification.

  6. Relationships of tree height and diameter at breast height revisited: analyses of stem growth using 20-year data of an even-aged Chamaecyparis obtusa stand

    PubMed Central

    Sumida, Akihiro; Miyaura, Tomiyasu; Torii, Hitoshi

    2013-01-01

    Stem diameter at breast height (DBH) and tree height (H) are commonly used measures of tree growth. We examined patterns of height growth and diameter growth along a stem using a 20-year record of an even-aged hinoki cypress (Chamaecyparis obtusa (Siebold & Zucc.) Endl.) stand. In the region of the stem below the crown (except for the butt swell), diameter growth rates (ΔD) at different heights tended to increase slightly from breast height upwards. This increasing trend was pronounced in suppressed trees, but not as much as the variation in ΔD among individual trees. Hence, ΔD below the crown can be regarded as generally being represented by the DBH growth rate (ΔDBH) of a tree. Accordingly, the growth rate of the stem cross-sectional area increased along the stem upwards in suppressed trees, but decreased in dominant trees. The stem diameter just below the crown base (DCB), the square of which is an index of the amount of leaves on a tree, was an important factor affecting ΔDBH. DCB also had a strong positive relationship with crown length. Hence, long-term changes in the DCB of a tree were associated with long-term changes in crown length, determined by the balance between the height growth rate (ΔH) and the rising rate of the crown base (ΔHCB). Within the crown, ΔD's were generally greater than the rates below the crown. Even dying trees (ΔD ≈ 0 below the crown) maintained ΔD > 0 within the crown and ΔH > 0 until about 5 years before death. This growth within the crown may be related to the need to produce new leaves to compensate for leaves lost owing to the longevity of the lower crown. These results explain the different time trajectories in DBH–H relationships among individual trees, and also the long-term changes in the DBH–H relationships. The view that a rise in the crown base is strongly related to leaf turnover helps to interpret DBH–H relationships. PMID:23303367

  7. Linking ice accretion and crown structure: towards a model of the effect of freezing rain on tree canopies.

    PubMed

    Nock, Charles A; Lecigne, Bastien; Taugourdeau, Olivier; Greene, David F; Dauzat, Jean; Delagrange, Sylvain; Messier, Christian

    2016-06-01

    Despite a longstanding interest in variation in tree species vulnerability to ice storm damage, quantitative analyses of the influence of crown structure on within-crown variation in ice accretion are rare. In particular, the effect of prior interception by higher branches on lower branch accumulation remains unstudied. The aim of this study was to test the hypothesis that intra-crown ice accretion can be predicted by a measure of the degree of sheltering by neighbouring branches. Freezing rain was artificially applied to Acer platanoides L., and in situ branch-ice thickness was measured directly and from LiDAR point clouds. Two models of freezing rain interception were developed: 'IceCube', which uses point clouds to relate ice accretion to a voxel-based index (sheltering factor; SF) of the sheltering effect of branch elements above a measurement point; and 'IceTree', a simulation model for in silico evaluation of the interception pattern of freezing rain in virtual tree crowns. Intra-crown radial ice accretion varied strongly, declining from the tips to the bases of branches and from the top to the base of the crown. SF for branches varied strongly within the crown, and differences among branches were consistent for a range of model parameters. Intra-crown variation in ice accretion on branches was related to SF (R(2) = 0·46), with in silico results from IceTree supporting empirical relationships from IceCube. Empirical results and simulations confirmed a key role for crown architecture in determining intra-crown patterns of ice accretion. As suspected, the concentration of freezing rain droplets is attenuated by passage through the upper crown, and thus higher branches accumulate more ice than lower branches. This is the first step in developing a model that can provide a quantitative basis for investigating intra-crown and inter-specific variation in freezing rain damage. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Retention Load Values of Telescopic Crowns Made of Y-TZP and CoCr with Y-TZP Secondary Crowns: Impact of Different Taper Angles

    PubMed Central

    Merk, Susanne; Wagner, Christina; Stock, Veronika; Schmidlin, Patrick R.; Roos, Malgorzata; Eichberger, Marlis; Stawarczyk, Bogna

    2016-01-01

    This study aimed to examine and compare the retention load values (RL) of different telescopic crown assemblies (Y-TZP and CoCr primary crowns with electroformed and Y-TZP secondary crowns each) with three different taper angles (0°, 1° and 2°). Thirty Y-TZP primary crowns with electroformed gold copings (Z/G group) and Y-TZP secondary crowns (Z/Z group) and 30 CoCr primary crowns with electroformed gold copings (C/G group) and Y-TZP secondary crowns (C/Z group), each with taper angles of 0°, 1° and 2°, were fabricated, respectively. With the exception of the electroformed gold copings, all specimens were Computer-Aided-Design/Computer-Aided-Manufacturing (CAD/CAM)-milled, then sintered and afterwards manually adapted. In order to stabilize the gold copings, they were fixed in a tertiary structure. The secondary crowns were constructed with a hook, which ensured self-alignment with an upper chain. Afterwards, 20 pull-off test cycles were performed in a universal testing machine under artificial saliva and after weighing the secondary crowns with a 5 kg object for 20 s. Data were analyzed by one-way and two-way Analysis of Variance (ANOVA). C/Z with 1° showed higher (p = 0.009) RL than 0° and 2° tapers. C/G at 1° also showed higher (p = 0.001) RL than at tapers of 0° and 2°. Z/G and C/G at 0° showed lower RL than Z/Z and C/Z (p < 0.001). Primary crowns had no impact on the 0° group. Z/G showed lower RL as compared to C/Z within the 1° group (p = 0.007) and Z/Z in the 2° group (p = 0.006). The primary crown material had no influence on RL. Electroformed copings showed lower RL. Further investigations for 1° as well as for the long-term performance after thermomechanical aging are necessary. PMID:28773477

  9. Marginal and internal adaptation of ceramic crown restorations fabricated with CAD/CAM technology and the heat-press technique.

    PubMed

    Mously, Hisham A; Finkelman, Matthew; Zandparsa, Roya; Hirayama, Hiroshi

    2014-08-01

    The accuracy of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) restorations is questionable, and the effect of the die spacer settings is not well stated in the literature. The purpose of the study was to evaluate the marginal and internal adaptation of E4D crowns fabricated with different spacer thicknesses and to compare these crowns with those fabricated with the heat-press technique. The E4D system was used to fabricate 30 crowns for the first 3 groups, with different spacer thickness settings: 30 μm, 60 μm, and 100 μm. In the fourth group, 10 lithium disilicate crowns were fabricated with the heat-press technique. The occlusal gap, axial gap, vertical marginal gap, and absolute marginal discrepancy were evaluated by x-ray microtomography. Statistical significance was assessed with the Kruskal-Wallis test (α=.05). For post hoc analyses, the Mann-Whitney U test was used alongside the Bonferroni correction for multiple comparisons (α=.008). Within the CAD/CAM groups, the 30-μm spacer thickness resulted in the lowest median axial gap (90.04 μm), whereas the 60-μm spacer thickness resulted in the lowest median occlusal gap (152.39 μm). The median marginal gap values of the CAD/CAM-60 group (49.35 μm) and CAD/CAM-100 group (46.65 μm) were lower than those of the CAD/CAM-30 group (55.18 μm). No significant differences among the CAD/CAM groups were observed for absolute marginal discrepancy. The heat-press group had significantly different values than those of the CAD/CAM groups. The spacer thickness and fabrication technique affected the adaptation of ceramic crowns. The heat-press group yielded the best marginal and internal crown adaptation results. The 30- or 60-μm spacer settings are recommended for the E4D CAD/CAM system. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Wind tunnel experiments to study chaparral crown fires

    Treesearch

    Jeanette Cobian-Iñiguez; AmirHessam Aminfar; Joey Chong; Gloria Burke; Albertina Zuniga; David R. Weise; Marko Princevac

    2017-01-01

    The present protocol presents a laboratory technique designed to study chaparral crown fire ignition and spread. Experiments were conducted in a low velocity fire wind tunnel where two distinct layers of fuel were constructed to represent surface and crown fuels in chaparral. Chamise, a common chaparral shrub, comprised the live crown layer. The dead fuel surface layer...

  11. Comparison of crown fire modeling systems used in three fire management applications

    Treesearch

    Joe H. Scott

    2006-01-01

    The relative behavior of surface-crown fire spread rate modeling systems used in three fire management applications-CFIS (Crown Fire Initiation and Spread), FlamMap and NEXUS- is compared using fire environment characteristics derived from a dataset of destructively measured canopy fuel and associated stand characteristics. Although the surface-crown modeling systems...

  12. Tree crown structure indicators in a natural uneven-aged mixed coniferous forest in northeastern Mexico

    Treesearch

    Javier Jimenez-Perez; Oscar Aguirre-Calderon; Horst Kramer

    2006-01-01

    Characterization of tree crown structure provides critical information to assess a variety of ecological conditions for multiple purposes and applications. For biomass growth, for example, tree crowns have basic physiological functions: assimilation, respiration, and transpiration. How tree crowns spatially interact and grow can bring about a seamless landscape of...

  13. Crown radius and diameter at breast height relationships for six bottomland hardwood species

    Treesearch

    Brian Roy Lockhart; Robert C. Weih; Keith M. Smith

    2005-01-01

    The relationship between a tree's crown radius and diameter at breast height (DBH) has a variety of uses including forest competition studies, tree crown densities, spacing and stocking relationships, wildlife habitat suitability models, and tree volume estimations. Estimating DBH from mean crown radius (MCR) is of interest to natural resource managers because MCR...

  14. Using crown condition variables as indicators of forest health

    Treesearch

    Stanley J. Zarnoch; William A. Bechtold; K.W. Stolte

    2004-01-01

    Indicators of forest health used in previous studies have focused on crown variables analyzed individually at the tree level by summarizing over all species. This approach has the virtue of simplicity but does not account for the three-dimensional attributes of a tree crown, the multivariate nature of the crown variables, or variability among species. To alleviate...

  15. Thinning guidelines from crown area relationships for young hardwood plantations

    Treesearch

    Jeffrey W. Stringer; Luke Cecil

    2010-01-01

    Crown closure in hardwood plantations signals the first opportunity to apply density control treatments such as thinning or release. The proper timing of these treatments is a function of stocking levels and is generally scheduled within several years after initial crown closure. Predicting crown closure for a plantation provides practitioners with the ability to plan...

  16. Digital photo monitoring for tree crown

    Treesearch

    Neil Clark; Sang-Mook Lee

    2007-01-01

    Assessing change in the amount of foliage within a tree’s crown is the goal of crown transparency estimation, a component in many forest health assessment programs. Many sources of variability limit analysis and interpretation of crown condition data. Increased precision is needed to detect more subtle changes that are important for detection of health problems....

  17. Digital photography for urban street tree crown conditions

    Treesearch

    Neil A. Clark; Sang-Mook Lee; William A. Bechtold; Gregory A. Reams

    2006-01-01

    Crown variables such as height, diameter, live crown ratio, dieback, transparency, and density are all collected as part of the overall crown assessment (USDA 2004). Transparency and density are related to the amount of foliage and thus the photosynthetic potential of the tree. These measurements are both currently based on visual estimates and have been shown to be...

  18. 33 CFR 165.T01-0176 - Regulated Navigation Area; Lake Champlain Bridge Construction, Crown Point, New York and Chimney...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Champlain Bridge Construction, Crown Point, New York and Chimney Point, Vermont. 165.T01-0176 Section 165...; Lake Champlain Bridge Construction, Crown Point, New York and Chimney Point, Vermont. (a) Description... and south of the Lake Champlain Bridge construction zone at Crown Point, New York and Chimney Point...

  19. [Cervical adaptation of complete cast crowns of various metal alloys, with and without die spacers].

    PubMed

    Stephano, C B; Roselino, R F; Roselino, R B; Campos, G M

    1989-01-01

    A metallic replica from a dental preparation for crown was used to make 8 class-IV stone dies. The wax patterns for the casting of the crowns were obtained in two conditions: a) from the stone die with no spacer; and b) from the stone die with an acrylic spacer. Thus, 64 metallic crowns were casted, using 4 different alloys: DURACAST (Cu-Al), NICROCAST (Ni-Cr) and DURABOND (Ni-Cr), and gold. The casted crowns were fitted in the metallic replica and measured as to the cervical discrepance of fitting. The results showed that the use of die spacers decreases the clinical discrepancies of fitting of the casted crowns (in a statistically significant level), no matter the metallic alloy employed.

  20. Comparison of the effects of friction varnish and electroforming on the retention of telescopic crowns.

    PubMed

    Özyemişci-Cebeci, Nuran; Yavuzyilmaz, Hüsnü

    2013-06-01

    Methods to improve the retention of telescopic crowns, including the application of friction varnish and electroforming, are available. However, information about their efficiency is limited. The purpose of this study was to compare the influence of 2 different friction varnishes and an electroforming method on the retention of telescopic crowns. Thirty inner and outer crowns were fabricated from cobalt-chromium-molybdenum alloy having lengths and cervical diameters of 6 mm, 2-degree tapers, and shoulder margins of 1 mm. Fifty-μm thick layers were removed from the internal surfaces of the outer crowns with a vertical machining center to simulate wear. The retentive forces of these specimens were measured with a testing machine. FGP friction varnish (FGP Friction-Fit-System), SD friction varnish (Servo-dental), and an electroforming method (GES\\Gold Electroforming System) were applied to the specimens. After the application of the 3 methods, retention values were measured, and the results analyzed with 1-way ANOVA, paired sample t test (α=.05). The increase in the retentive forces of all specimens was statistically significant (P<.01). The mean retentive forces increased from 3.6 N to 9.8 N for group FGP, 3.6 N to 4.6 N for group SD, and 3.7 N to 6.0 N for group EF. Group FGP was significantly different from group SD and group EF (P<.05), and no significant difference was observed between group SD and group EF. Mean standard deviation values of retentive forces for group FGP before, FGP after, SD before, SD after, EF before and EF after is 0.5, 2.7, 0.6, 1.3, 0.8, 2.3, respectively. Group FGP showed the maximum retention values. Group EF showed higher retention values than group SD. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  1. Thermodynamics and kinetics of gas storage in porous liquids

    DOE PAGES

    Zhang, Fei; Yang, Fengchang; Huang, Jingsong; ...

    2016-07-05

    The recent synthesis of organic molecular liquids with permanent porosity (Giri et al., Nature, 2015, 527, 216) opens up exciting new avenues for gas capture, storage, and separation. Using molecular dynamics simulations, we study the thermodynamics and kinetics for the storage of CH 4, CO 2, and N 2 molecules in porous liquids consisting of crown-ether substituted cage molecules in a 15-crown-5 solvent. It is found that the gas storage capacity per cage molecule follows the order of CH 4 > CO 2 > N 2, which does not correlate simply with the size of gas molecules. Different gas moleculesmore » are stored inside the cage differently, e.g., CO 2 molecules prefer the cage s core while CH 4 molecules favor both the core and the branch regions. All gas molecules considered can enter the cage essentially without energy barriers, and their dynamics inside the cage are only slightly hindered by the nanoscale confinement. In addition, all gas molecules can leave the cage on nanosecond time scale by overcoming a modest energy penalty. The molecular mechanisms of these observations are clarified.« less

  2. Thermodynamics and kinetics of gas storage in porous liquids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Fei; Yang, Fengchang; Huang, Jingsong

    The recent synthesis of organic molecular liquids with permanent porosity (Giri et al., Nature, 2015, 527, 216) opens up exciting new avenues for gas capture, storage, and separation. Using molecular dynamics simulations, we study the thermodynamics and kinetics for the storage of CH 4, CO 2, and N 2 molecules in porous liquids consisting of crown-ether substituted cage molecules in a 15-crown-5 solvent. It is found that the gas storage capacity per cage molecule follows the order of CH 4 > CO 2 > N 2, which does not correlate simply with the size of gas molecules. Different gas moleculesmore » are stored inside the cage differently, e.g., CO 2 molecules prefer the cage s core while CH 4 molecules favor both the core and the branch regions. All gas molecules considered can enter the cage essentially without energy barriers, and their dynamics inside the cage are only slightly hindered by the nanoscale confinement. In addition, all gas molecules can leave the cage on nanosecond time scale by overcoming a modest energy penalty. The molecular mechanisms of these observations are clarified.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Fei; He, Yadong; Huang, Jingsong

    Porous liquids are a promising new class of materials featuring nanoscale cavity units dispersed in liquids that are suitable for applications such as gas storage and separation. In this work, we use molecular dynamics simulations to examine the multicomponent gas storage in a porous liquid consisting of crown-ether-substituted cage molecules dissolved in a 15-crown-5 solvent. We compute the storage of three prototypical small molecules including CO 2, CH 4, and N 2 and their binary mixtures in individual cage molecules. For porous liquids in equilibrium with a binary 1:1 gas mixture bath with partial gas pressure of 27.5 bar, amore » cage molecule shows a selectivity of 4.3 and 13.1 for the CO 2/CH 4 and CO 2/N 2 pairs, respectively. We provide a molecular perspective of how gas molecules are stored in the cage molecule and how the storage of one type of gas molecule is affected by other types of gas molecules. Finally, our results clarify the molecular mechanisms behind the selectivity of such cage molecules toward different gases.« less

  4. Multicomponent Gas Storage in Organic Cage Molecules

    DOE PAGES

    Zhang, Fei; He, Yadong; Huang, Jingsong; ...

    2017-05-18

    Porous liquids are a promising new class of materials featuring nanoscale cavity units dispersed in liquids that are suitable for applications such as gas storage and separation. In this work, we use molecular dynamics simulations to examine the multicomponent gas storage in a porous liquid consisting of crown-ether-substituted cage molecules dissolved in a 15-crown-5 solvent. We compute the storage of three prototypical small molecules including CO 2, CH 4, and N 2 and their binary mixtures in individual cage molecules. For porous liquids in equilibrium with a binary 1:1 gas mixture bath with partial gas pressure of 27.5 bar, amore » cage molecule shows a selectivity of 4.3 and 13.1 for the CO 2/CH 4 and CO 2/N 2 pairs, respectively. We provide a molecular perspective of how gas molecules are stored in the cage molecule and how the storage of one type of gas molecule is affected by other types of gas molecules. Finally, our results clarify the molecular mechanisms behind the selectivity of such cage molecules toward different gases.« less

  5. Tree crown structural characterization: A study using terrestrial laser scanning and three-dimensional radiative transfer modeling

    NASA Astrophysics Data System (ADS)

    Moorthy, Inian

    Spectroscopic observational data for vegetated environments, have been coupled with 3D physically-based radiative transfer models for retrievals of biochemical and biophysical indicators of vegetation health and condition. With the recent introduction of Terrestrial Laser Scanning (TLS) units, there now exists a means of rapidly measuring intricate structural details of vegetation canopies, which can also serve as input into 3D radiative transfer models. In this investigation, Intelligent Laser Ranging and Imaging System (ILRIS-3D) data was acquired of individual tree crowns in laboratory, and field-based experiments. The ILRIS-3D uses the Time-Of-Flight (TOF) principle to measure the distances of objects based on the time interval between laser pulse exitance and return, upon reflection from an object. At the laboratory-level, this exploratory study demonstrated and validated innovative approaches for retrieving crown-level estimates of Leaf Area Index (LAI) (r2 = 0.98, rmse = 0.26m2/m2), a critical biophysical parameter for vegetation monitoring and modeling. These methods were implemented and expanded in field experiments conducted in olive (Olea europaea L.) orchards in Cordoba, Spain, where ILRIS-3D observations for 24 structurally-variable trees were made. Robust methodologies were developed to characterize diagnostic architectural parameters, such as tree height (r2 = 0.97, rmse = 0.21m), crown width (r 2 = 0.98, rmse = 0.12m), crown height (r2 = 0.81, rmse = 0.11m), crown volume (r2 = 0.99, rmse = 2.6m3), and LAI (r2 = 0.76, rmse = 0.27m2/ m2). These parameters were subsequently used as direct inputs into the Forest LIGHT (FLIGHT) 3D ray tracing model for characterization of the spectral behavior of the olive crowns. Comparisons between FLIGHT-simulated spectra and measured data showed small differences in the visible (< 3%) and near infrared (< 10%) spectral ranges. These differences between model simulations and measurements were significantly correlated to TLS-derived tree crown complexity metrics. The specific implications of internal crown complexity on estimating leaf chlorophyll concentration, a pertinent physiological health indicator, is highlighted. This research demonstrates that TLS systems can potentially be the new observational tool and benchmark for precise characterization of vegetation architecture for synergy with 3D radiative transfer models for improved operational management of agricultural crops.

  6. Effects of taper and space settings of telescopic Ce-TZP/A crowns on retentive force and settling.

    PubMed

    Nakagawa, Shusuke; Torii, Katsunori; Tanaka, Masahiro

    2017-03-31

    The aim of this study was to investigate the effect of the taper and space setting of using Ce-TZP/A on retentive force and secondary crown settling. The taper were 2°, 4°, and 6°, and the space settings were 0 and 10 μm. The applied loads were 50 and 100 N. The taper had a significant effect on retentive force and settling at both loads (p<0.05). The space settings did not have a significant effect on retentive force or settling at either load (p<0.05). The taper of the telescopic crowns and the load affected the retentive force and the settling.

  7. [Analysis of the unsuccessful cases of the porcelain-fused-to-metal-crowns and bridges].

    PubMed

    Zhai, Li-Yun; Zhao, Yu-Zhen; Wang, Shao-Ping; Yang, Yue-Hua

    2005-06-01

    To discuss the unsuccessful reasons and the preventive methods of the unsuccessful clinic cases. The retrospective analysis was carried on the 80 prosthesis in 70 patients from 1994 to 2001 which were suffered with unsuccessful results after the restoration of the metal crowns and bridges. There were 68 teeth which had collapsed or broken. 20 teeth had the post loosing or shedding. Root breaking, food impaction, unharmony colors of porcelain and the changing color of gingival were 3, 3, 6 and 2 teeth. It is necessary to select suitable repairing materials and operate correctly for preventing the occurring of the unsuccessful results in the porcelain-fused-to-metal-crowns and bridges.

  8. Longevity and clinical performance of IPS-Empress ceramic restorations--a literature review.

    PubMed

    El-Mowafy, Omar; Brochu, Jean-François

    2002-04-01

    A literature review of longevity and clinical performance of IPS-Empress restorations is presented. A MEDLINE search was conducted in fall 2000. Selection criteria were set so as to identify suitable clinical trials that were published in full and that had lasted more than 2 years. A total of 6 clinical trials on the performance of IPS-Empress inlays and onlays and a total of 3 clinical trials on the performance of IPS-Empress crowns were identified. Survival rates for IPS-Empress inlays and onlays ranged from 96% at 4.5 years to 91% at 7 years; most failures were due to bulk fracture. IPS-Empress crowns had a survival rate ranging from 92% to 99% at 3 to 3.5 years; crown failure was also mainly due to fracture. Dentists should inform their patients about these survival rates when offering such treatment. The use of IPS-Empress crowns in the posterior of the mouth is not recommended until the results of more long-term clinical trials are available.

  9. Evaluation of different sterilization and disinfection methods on commercially made preformed crowns.

    PubMed

    Yilmaz, Y; Guler, C

    2008-12-01

    The aim of this study was to evaluate the changes caused by different sterilization or disinfection methods on the vestibular surface of four commercially made preformed crowns using stereomicroscopy and scanning electron microscopy (SEM). Preformed crowns (NuSmile Primary Anterior Crown (NSC), Kinder Krowns (KK), Pedo Pearls (PP) and polycarbonate crowns (PC)) were sterilized and/or disinfected by one of the following techniques: no sterilization or disinfection (G1 control group); steam autoclaving at 134 degrees C (30 psi) for 4 min (G2); steam autoclaving at 134 degrees C (30 psi) for 12 min (G3); steam autoclaving at 121 degrees C (15 psi) for 30 min (G4); and ultrasonication in a bath containing 4% Lysetol AF for 5 min at room temperature (chemical disinfection) (G5). Scanning electron micrographs of the crowns were taken before and after their sterilization or disinfection. The changes on the vestibular surface were then scored for the presence or absence of crazing, contour alteration, fracturing, and vestibular surface changes. The data were analyzed statistically using the chi-square test. No changes were observed before and after sterilization or disinfection in the stereomicroscopic evaluation of the vestibular surface of the crowns. However, all methods in which steam autoclaving was used to sterilize the crowns caused significant (P < 0.05) crazing and contour alterations of the vestibular surface of the crowns when they were examined by SEM. Chemical disinfection using an aldehyde-free disinfectant is the preferred method of disinfection for crowns that have been used previously in other dental patients.

  10. Crown condition dynamics of oak in southern Sweden 1988-1999.

    PubMed

    Drobyshev, Igor; Anderson, Stefan; Sonesson, Kerstin

    2007-11-01

    Crown defoliation of oak (Quercus robur and Q. petraea) was analysed in 808 trees during three forest condition surveys (1988, 1993, and 1999) in the southern Sweden. From 1988 to 1999 crown defoliation increased by more than 20%. Changes in crown defoliation were related to the pH in the upper 20-30 cm of the mineral soils, which was closely connected to other measures of soil fertility (cation exchange capacity, CEC and C/N ratio). Trees growing on soils with a high pH (> or =4.00, in BaCl2 filtrate), high CEC and low C/N ratio had significantly lower crown defoliation than trees growing on more acid soils (pH <4.00), indicating that less favourable soil conditions may further enhance oak decline. Age did not differentiate trees with respect to crown defoliation, indicating that decline in crown condition was not due to an age-related increase in crown transparency. Considering only trees younger than 100 years, a significant interaction was observed between changes in crown defoliation and soil pH. Trees younger than 100 years old growing on more acidic soils had a greater increase in crown transparency than trees on more basic soils between 1988 and 1999. Trees > or =100 years old had significantly higher defoliation on more acidic than on more basic soils, however defoliation dynamics of these trees over 1988-99 was not related to soil acidity. Two biotic agents (insect and fungal leaf infections) evaluated in this study did not prove to be important drivers of defoliation dynamics.

  11. Fracture resistance of aluminium oxide and lithium disilicate-based crowns using different luting cements: an in vitro study.

    PubMed

    Al-Wahadni, Ahed M; Hussey, David L; Grey, Nicholas; Hatamleh, Muhanad M

    2009-03-01

    The aim of this study was to investigate the fracture resistance of two types of ceramic crowns cemented with two different cements. Forty premolar crowns were fabricated using lithium-disilicate (IPS Empress-2) and glass-infiltrated aluminium-oxide (In-Ceram) ceramic systems. The crowns were divided into four groups (n=10) with Group 1 (IPS Empress-2) and Group 2 (In-Ceram) cemented with glass ionomer cement. Group 3 (IPS Empress-2) and Group 4 (In-Ceram) were cemented with resin cement. Crowns were tested in a universal testing machine at a compressive-load speed of 10 mm/min. Fracture modes were grouped into five categories. One way analysis of variance (ANOVA) and Bonferroni post-hoc tests were used to detect statistical significances (p<0.05). The mean (SD) fracture resistance (Newtons) for Groups 1 to 4 were: 245.35 (82.69), 390.48 (67.03), 269.69 (10.33), and 418.36 (26.24). The cement type had no statistical significant effect (p>0.05) on fracture resistance within each ceramic system tested. In-Ceram crowns cemented with either glass ionomer or resin cements exhibited a statistically significantly higher fracture-resistance than IPS Empress-2 crowns (p<0.05). Minimal fracture in the test crowns was the common mode exhibited. Fracture resistance of IPS Empress-2 and In-Ceram crowns was not affected by the type of cement used for luting. Both In-Ceram and IPS Empress-2 crowns can be successfully luted with the cements tested with In-Ceram exhibiting higher fracture resistance than IPS Empress-2.

  12. Two-body wear comparison of zirconia crown, gold crown, and enamel against zirconia.

    PubMed

    Kwon, Min-Seok; Oh, Sang-Yeob; Cho, Sung-Am

    2015-07-01

    Full zirconia crowns have recently been used for dental restorations because of their mechanical properties. However, there is little information about their wear characteristics against enamel, gold, and full zirconia crowns. The purpose of this study was to compare the wear rate of enamel, gold crowns, and zirconia crowns against zirconia blocks using an in vitro wear test. Upper specimens were divided into three groups: 10 enamels (group 1), 10 gold crowns (group 2, Type III gold), and 10 zirconia crowns (group 3, Prettau(®)Zirkon 9H, Zirkonzahn, Italy). Each of these specimens was wear tested against a zirconia block (40×30×3mm(3)) as a lower specimen (30 total zirconia blocks). Each specimen of the groups was abraded against the zirconia block for 600 cycles at 1Hz with 15mm front-to-back movement on an abrading machine. Moreover, the load applied during the abrading test was 50N, and the test was performed in a normal saline emulsion for 10min. Three-dimensional images were taken before and after the test, and the statistical analysis was performed using the Krushal-Wallis test and Mann-Whitney test (p=0.05). The mean volume loss of group 1 was 0.47mm(3), while that of group 2 and group 3 was 0.01mm(3). The wear volume loss of enamels against zirconia was higher than that of gold and zirconia crowns. Moreover, according to this result, zirconia crowns are not recommended for heavy bruxers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Genome-Wide Association Mapping of Crown Rust Resistance in Oat Elite Germplasm.

    PubMed

    Klos, Kathy Esvelt; Yimer, Belayneh A; Babiker, Ebrahiem M; Beattie, Aaron D; Bonman, J Michael; Carson, Martin L; Chong, James; Harrison, Stephen A; Ibrahim, Amir M H; Kolb, Frederic L; McCartney, Curt A; McMullen, Michael; Fetch, Jennifer Mitchell; Mohammadi, Mohsen; Murphy, J Paul; Tinker, Nicholas A

    2017-07-01

    Oat crown rust, caused by f. sp. , is a major constraint to oat ( L.) production in many parts of the world. In this first comprehensive multienvironment genome-wide association map of oat crown rust, we used 2972 single-nucleotide polymorphisms (SNPs) genotyped on 631 oat lines for association mapping of quantitative trait loci (QTL). Seedling reaction to crown rust in these lines was assessed as infection type (IT) with each of 10 crown rust isolates. Adult plant reaction was assessed in the field in a total of 10 location-years as percentage severity (SV) and as infection reaction (IR) in a 0-to-1 scale. Overall, 29 SNPs on 12 linkage groups were predictive of crown rust reaction in at least one experiment at a genome-wide level of statistical significance. The QTL identified here include those in regions previously shown to be linked with seedling resistance genes , , , , , and and also with adult-plant resistance and adaptation-related QTL. In addition, QTL on linkage groups Mrg03, Mrg08, and Mrg23 were identified in regions not previously associated with crown rust resistance. Evaluation of marker genotypes in a set of crown rust differential lines supported as the identity of . The SNPs with rare alleles associated with lower disease scores may be suitable for use in marker-assisted selection of oat lines for crown rust resistance. Copyright © 2017 Crop Science Society of America.

  14. Sampling western spruce budworm by counting larvae on lower crown branches.

    Treesearch

    R.R. Mason; B.E. Wickman; H.G. Paul

    1989-01-01

    A technique is described for sampling spruce budworm larvae after bud flush by nondestructively beating branches in the lower crown. Sample data were collected from 32 plots representing a wide range of budworm densities. Statistical analyses indicated that larvae were less aggregated in the lower crown than at the same density in the middle crown. In an independent...

  15. Estimating tree crown widths for the primary Acadian species in Maine

    Treesearch

    Matthew B. Russell; Aaron R. Weiskittel

    2012-01-01

    In this analysis, data for seven conifer and eight hardwood species were gathered from across the state of Maine for estimating tree crown widths. Maximum and largest crown width equations were developed using tree diameter at breast height as the primary predicting variable. Quantile regression techniques were used to estimate the maximum crown width and a constrained...

  16. Urban Crowns: crown analysis software to assist in quantifying urban tree benefits

    Treesearch

    Matthew F. Winn; Sang-Mook Lee Bradley; Philip A. Araman

    2010-01-01

    UrbanCrowns is a Microsoft® Windows®-based computer program developed by the U.S. Forest Service Southern Research Station. The software assists urban forestry professionals, arborists, and community volunteers in assessing and monitoring the crown characteristics of urban trees (both deciduous and coniferous) using a single side-view digital photograph. Program output...

  17. Colorimetric values of esthetic stainless steel crowns.

    PubMed

    Hosoya, Yumiko; Omachi, Koichi; Staninec, Michal

    2002-01-01

    The colorimetric values of two different kinds of esthetic stainless steel crowns were measured and compared with the colorimetric values of primary anterior teeth in Japanese children. The colorimetric values of resin composite-faced stainless steel crowns (Kinder Krown) and epoxy-coated stainless steel crowns (White Steel Crown) were measured with a color difference meter. The Commission Internationale de Eclairage L*, a*, b*, and delta E*ab values and Munsell value, chroma, and hue were calculated. The data were compared with previously reported colorimetric values of Japanese primary anterior teeth measured with the same color difference meter used in this study. Compared to Japanese primary anterior teeth, Kinder Krown Pedo I and Pedo II showed much higher L* values and lower hue; on the other hand, White Steel Crown showed much higher L*, a*, b* values, much higher value and chroma, and much lower hue. Color analysis revealed that the colors of the White Steel Crown and Kinder Krown Pedo I were substantially different from the color of Japanese primary anterior teeth. The color difference between Pedo II crowns and Japanese primary anterior teeth was relatively high, but the color of Pedo II might be acceptable for clinical use.

  18. The effect of luting media on the fracture resistance of a flame sprayed all-ceramic crown.

    PubMed

    Casson, A M; Glyn Jones, J C; Youngson, C C; Wood, D J

    2001-11-01

    This in vitro study investigated the effect of selected luting media on the fracture resistance of a flame-sprayed all-ceramic crown. Three groups of 10 human upper premolar teeth were prepared for crowning using a standardised technique. Flame sprayed crowns were fabricated and cemented onto the preparations using zinc phosphate (ZPC), glass polyalkenoate (GPC) or composite luting cement (CLC). During crown seating, a pressure perfusion system simulated pulpal fluid outflow equivalent to 300mm of H2O. Compressive fracture resistance was determined for each group using a Universal Testing Machine with a crosshead speed of 1mm min(-1). A group of unrestored teeth acted as a control. The fracture resistance of the groups ranked as follows: ZPC>CLC>GPC=unrestored teeth. The difference between the fracture resistance of ZPC and CLC groups and the control group was statistically significant. The mode of fracture between the luted crowns and natural crowns was markedly different. When tested in compression, a new, flame-sprayed all-ceramic crown, when luted in place using ZPC, GPC or CLC, could produce strengths comparable to or greater than natural unrestored teeth. The luting agent used significantly affected the recorded fracture loads.

  19. [Fatigue damage analysis of porcelain in all-ceramic crowns].

    PubMed

    Liu, Yi-hong; Feng, Hai-lan; Liu, Guang-hua; Shen, Zhi-jian

    2010-02-18

    To investigate the fatigue damage mechanism of porcelain, and its relation with the microscopic defects in clinically failed all-ceramic crowns. Collecting the bilayered all-ceramic crowns failed in vivo. The fractured surfaces and occlusial surfaces of failed crowns were examined by an optical microscope followed by detailed fractography investigations using a field emission scanning electron microscope. When chemical impurities were of concern, energy-dispersive X-ray spectroscopy analysis was performed to examine chemical composition. A standard practice for fractography failure analysis of advanced ceramics is applied to disclose the fracture mode, and damage character. Three types of fracture features are defined as breakdown of the entire crown, and porcelain chipping-off/delamination. Alumina crowns were usually characterized by breakdown of the entire crown, while zirconia crowns by porcelain chipping-off and delamination. The fatigue damage of porcelain was classified into surface wear, cone crack, and porcelain delamination. The observed microscopic defects in this study included air bubbles and impurity particles. The multi-point occlusial contacts were recommended in all-ceramic restorations clinically. The thickness of porcelain is important for the anti-fatigue ability of porcelain. Cautions have to be taken to avoid contaminations during the veneering processes.

  20. Olive Crown Porosity Measurement Based on Radiation Transmittance: An Assessment of Pruning Effect.

    PubMed

    Castillo-Ruiz, Francisco J; Castro-Garcia, Sergio; Blanco-Roldan, Gregorio L; Sola-Guirado, Rafael R; Gil-Ribes, Jesus A

    2016-05-19

    Crown porosity influences radiation interception, air movement through the fruit orchard, spray penetration, and harvesting operation in fruit crops. The aim of the present study was to develop an accurate and reliable methodology based on transmitted radiation measurements to assess the porosity of traditional olive trees under different pruning treatments. Transmitted radiation was employed as an indirect method to measure crown porosity in two olive orchards of the Picual and Hojiblanca cultivars. Additionally, three different pruning treatments were considered to determine if the pruning system influences crown porosity. This study evaluated the accuracy and repeatability of four algorithms in measuring crown porosity under different solar zenith angles. From a 14° to 30° solar zenith angle, the selected algorithm produced an absolute error of less than 5% and a repeatability higher than 0.9. The described method and selected algorithm proved satisfactory in field results, making it possible to measure crown porosity at different solar zenith angles. However, pruning fresh weight did not show any relationship with crown porosity due to the great differences between removed branches. A robust and accurate algorithm was selected for crown porosity measurements in traditional olive trees, making it possible to discern between different pruning treatments.

Top