Ahmed, Omar H; Marcus, Sonya; Tauber, Jenna R; Wang, Binhuan; Fang, Yixin; Lebowitz, Richard A
2017-01-01
Objective Perioperative lumbar drain (LD) use in the setting of endoscopic cerebrospinal fluid (CSF) leak repair is a well-established practice. However, recent data suggest that LDs may not provide significant benefit and may thus confer unnecessary risk. To examine this, we conducted a meta-analysis to investigate the effect of LDs on postoperative CSF leak recurrence following endoscopic repair of CSF rhinorrhea. Data Sources A comprehensive search was performed with the following databases: Ovid MEDLINE (1947 to November 2015), EMBASE (1974 to November 2015), Cochrane Review, and PubMed (1990 to November 2015). Review Method A meta-analysis was performed according to PRISMA guidelines. Results A total of 1314 nonduplicate studies were identified in our search. Twelve articles comprising 508 cases met inclusion criteria. Overall, use of LDs was not associated with significantly lower postoperative CSF leak recurrence rates following endoscopic repair of CSF rhinorrhea (odds ratio: 0.89, 95% confidence interval: 0.40-1.95) as compared with cases performed without LDs. Subgroup analysis of only CSF leaks associated with anterior skull base resections (6 studies, 153 cases) also demonstrated that lumbar drainage did not significantly affect rates of successful repair (odds ratio: 2.67, 95% confidence interval: 0.64-11.10). Conclusions There is insufficient evidence to support that adjunctive lumbar drainage significantly reduces postoperative CSF leak recurrence in patients undergoing endoscopic CSF leak repair. Subgroup analysis examining only those patients whose CSF leaks were associated with anterior skull base resections demonstrated similar results. More level 1 and 2 studies are needed to further investigate the efficacy of LDs, particularly in the setting of patients at high risk for CSF leak recurrence.
Use of duraseal in repair of cerebrospinal fluid leaks.
Chin, Christopher J; Kus, Lukas; Rotenberg, Brian W
2010-10-01
The purpose of our article is to review the use of the DuraSeal Sealant System (Confluent Surgical Inc., Waltham, MA) in the repair of complex cerebrospinal fluid (CSF) leaks in endoscopic skull-base surgery. Retrospective chart review. London Health Sciences Centre. A database of endoscopic skull-base cases between 2007 and 2009 that involved CSF leakage repaired with DuraSeal was created. Demographic data and operative reports were collected and analyzed qualitatively. Recurrence of CSF leak after repair. Five cases were identified that met study criteria. In four of the five cases, the repair was successful. There were no complications related to DuraSeal use. Comparison to a subset of patients using Tisseel Fibrin Sealant (Baxter, Toronto, ON) for repair did not show a significant difference in failure rate (χ2 = 0.029, p = .858). There are a variety of techniques described to repair CSF rhinorrhea, with various studies demonstrating the advantages of using tissue glues in CSF leak repairs. We used DuraSeal in five patients to enhance graft strength and form a watertight seal. The system was effective in the majority of patients. Our study is the first to report on endoscopic endonasal repair of CSF leaks using DuraSeal.
Mehta, Gautam U; Oldfield, Edward H
2012-06-01
Cerebrospinal fluid leakage is a major complication of transsphenoidal surgery. An intraoperative CSF leak, which occurs in up to 50% of pituitary tumor cases, is the only modifiable risk factor for postoperative leaks. Although several techniques have been described for surgical repair when an intraoperative leak is noted, none has been proposed to prevent an intraoperative CSF leak. The authors postulated that intraoperative CSF drainage would diminish tension on the arachnoid, decrease the rate of intraoperative CSF leakage during surgery for larger tumors, and reduce the need for surgical repair of CSF leaks. The results of 114 transsphenoidal operations for pituitary macroadenoma performed without intraoperative CSF drainage were compared with the findings from 44 cases in which a lumbar subarachnoid catheter was placed before surgery to drain CSF at the time of dural exposure and tumor removal. Cerebrospinal fluid drainage reduced the rate of intraoperative CSF leakage from 41% to 5% (p < 0.001). This reduction occurred in macroadenomas with (from 57% to 5%, p < 0.001) and those without suprasellar extension (from 29% to 0%, p = 0.31). The rate of postoperative CSF leakage was similar (5% vs 5%), despite the fact that intraoperative CSF drainage reduced the need for operative repair (from 32% to 5%, p < 0.001). There were no significant catheter-related complications. Cerebrospinal fluid drainage during transsphenoidal surgery for macroadenomas reduces the rate of intraoperative CSF leaks. This preventative measure obviated the need for surgical repair of intraoperative CSF leaks using autologous fat graft placement, other operative techniques, postoperative lumbar drainage, and/or reoperation in most patients and is associated with minimal risks.
Lucke-Wold, Brandon; Mendez, Gustavo; Cua, David; Akins, Paul; Gillham, Haley; Ciporen, Jeremy
2018-01-01
High flow orbital apex or middle fossa cerebrospinal fluid (CSF) leaks can be life threatening and complex to repair. These leaks associated with large dural defects are most commonly repaired with an open temporalis muscle patch or free flaps, but these flaps do not always stop the leak. A 65-year-old patient presented two years after orbital exenteration and radiation for squamous cell carcinoma. He developed multi-organism meningitis and pneumocephalus secondary to a large high-flow orbital apex/middle fossa CSF leak. To repair the leak, a combined endoscopic transorbital/endonasal approach with pedicled nasospetal flap and dermis fat graft was used. We describe the unique endoscopic technique that was used to treat the life threatening high flow orbital apex/middle fossa CSF leak. The technique allowed the use of the transposed pedicled flap, which is an alternative to the free flap in controlling CSF leak. Cisternogram post-operatively and clinical exam confirmed resolution of CSF leak. Although a critically ill patient at admission with a modified Rankin scale (MRS) of 5, he was discharged home on continued IV antibiotic therapy with a MRS of 3. Endoscopic evaluation at three months after treatment showed the effectiveness of the flap and he continued to improve clinically. This is the first case to describe a combined endoscopic transorbital and endonasal repair of high flow orbital apex/middle fossa CSF leak with a pedicled nasoseptal flap. These techniques can be utilized during initial reconstruction after orbital exenteration or as a salvage flap.
Han, Zong-Li; He, Dong-Sheng; Mao, Zhi-Gang; Wang, Hai-Jun
2008-06-01
To determine the incidence, risk factors, diagnostic procedures, and management of cerebrospinal fluid (CSF) leaks following trans-sphenoidal pituitary macroadenoma surgery. Retrospective analysis of 592 patients. Intra- and post-operative CSF leaks occurred in 14.2 and 4.4% of patients, respectively. Surgical revision, tumor consistency, and tumor margins were independently associated with intra-operative leaks, while the tumor size, consistency, and margins were risk factors of post-operative leaks. The intra-operative leak rate of ACTH adenomas was greater than all other types combined; the incidence of post-operative CSF leaks was highest for FSH adenomas. There were no significant differences among various techniques and we achieved an initial repair success rates of 83.3 and 92.9% for intra- and post-operative CSF leaks, respectively. Of the 26 patients with post-operative CSF leaks, five were complicated by meningitis and four by post-infectious hydrocephalus which required ventriculoperitoneal shunts. CSF leaks have a propensity to occur in cases with fibrous tumors or tumors with indistinct margin and may have some relationship with the tumor type. Endoscopic and microscopic repairs were shown to be effective techniques in managing these types of leaks. Post-infectious hydrocephalus may influence the outcome of the repair and ventriculoperitoneal shunts were necessary in some cases.
Black, P
2000-01-01
Cerebrospinal fluid (CSF) leaks are relatively common following spinal or posterior fossa surgery. A midline dural tear in the spine is readily repaired by direct application of a suture. However, far-lateral or ventral dural tears are problematic. Fat is an ideal sealant because it is impermeable to water. In this paper the author reports his experience with using fat grafts for the prevention or repair of CSF leaks and proposes a technique in which a large sheet of fat, harvested from the patient's subcutaneous layer, is used to cover not only the dural tear(s) but all of the exposed dura and is tucked into the lateral recess. This procedure prevents CSF from seeping around the fat, which may be tacked to the dura with a few sutures. Fibrin glue is spread on the surface of the fat and is further covered with Surgicel or Gelfoam. For ventral dural tears (associated with procedures in which disc material is excised), fat is packed into the disc space to seal off the ventral dural leak. Leaks in the posterior fossa are managed similarly to those in the spine. Dural suture lines, following suboccipital or spinal intradural exploration, are prophylactically protected from CSF leakage in the same manner. With one exception, 27 dural tears noted during 1650 spinal procedures were successfully repaired using this technique. There was one case of postoperative CSF leakage in 150 cases in which intradural exploration for tumor or other lesions was undertaken. Both postoperative CSF leaks were controlled by applying additional skin sutures. The use of a fat graft is recommended as a rapid, effective means of prevention and repair of CSF leaks following posterior fossa and spinal surgery.
Black, Perry
2002-03-01
Cerebrospinal fluid (CSF) leaks are relatively common following spinal surgery. A midline dural tear in the spine is readily repaired by direct application of sutures; however, far-lateral or ventral dural tears are problematic. Fat is an ideal sealant because it is impermeable to water. In this paper the author reports his experience with using fat grafts for the prevention or repair of CSF leaks and proposes a technique in which a large sheet of fat, harvested from the patient's subcutaneous layer, is used to cover not only the dural tear(s) but all of the exposed dura and is tucked into the lateral recess. This procedure prevents CSF from seeping around the fat, which may be tacked to the dura with a few sutures. Fibrin glue is spread on the surface of the fat and is further covered with Surgicel or Gelfoam. For ventral dural tears (associated with procedures in which disc material is excised), fat is packed into the disc space to seal off the ventral dural leak. Dural suture lines following spinal intradural exploration are prophylatically protected from CSF leakage in the same manner. With one exception, 27 dural tears noted during 1650 spinal procedures were successfully repaired using this technique. There was one case of postoperative CSF leakage in 140 cases in which intradural exploration for tumor or other lesions was undertaken. Both postoperative CSF leaks were controlled by applying additional skin sutures. The use of a fat graft is recommended as a rapid, effective means of prevention and repair of CSF leaks following spinal surgery.
False localizing sign of cervico-thoracic CSF leak in spontaneous intracranial hypotension.
Schievink, Wouter I; Maya, M Marcel; Chu, Ray M; Moser, Franklin G
2015-06-16
Spontaneous spinal CSF leaks are an important cause of new-onset headaches. Such leaks are reported to be particularly common at the cervico-thoracic junction. The authors undertook a study to determine the significance of these cervico-thoracic CSF leaks. The patient population consisted of a consecutive group of 13 patients who underwent surgery for CSF leak repair based on CT myelography showing CSF extravasation at the cervico-thoracic junction but without any evidence of an underlying structural lesion. The mean age of the 9 women and 4 men was 41.2 years. Extensive extrathecal longitudinal CSF collections were demonstrated in 11 patients. At surgery, small leaking arachnoid cysts were found in 2 patients. In the remaining 11 patients, no clear source of CSF leakage could be identified at surgery. Resolution of symptoms was achieved in both patients with leaking arachnoid cysts, but in only 3 of the 11 patients with negative intraoperative findings. Postoperative spinal imaging was performed in 9 of the 11 patients with negative intraoperative findings and showed persistence of the longitudinal intraspinal extradural CSF. Further imaging revealed the site of the CSF leak to be ventral to the thoracic spinal cord. Five of these patients underwent microsurgical repair of the ventral CSF leak with resolution of symptoms in all 5 patients. Cervico-thoracic extravasation of dye on myelography does not necessarily indicate the site of the CSF leak. Treatment directed at this site should not be expected to have a high probability of sustained improvement of symptoms. © 2015 American Academy of Neurology.
Stapleton, Amanda L; Tyler-Kabara, Elizabeth C; Gardner, Paul A; Snyderman, Carl H; Wang, Eric W
2017-02-01
To determine the risk factors associated with cerebrospinal fluid (CSF) leak following endoscopic endonasal surgery (EES) for pediatric skull base lesions. Retrospective chart review of pediatric patients (ages 1 month to 18 years) treated for skull base lesions with EES from 1999 to 2014. Five pathologies were reviewed: craniopharyngioma, clival chordoma, pituitary adenoma, pituitary carcinoma, and Rathke's cleft cyst. Fisher's exact tests were used to evaluate the different factors to determine which had a statistically higher risk of leading to a post-operative CSF leak. 55 pediatric patients were identified who underwent 70 EES's for tumor resection. Of the 70 surgeries, 47 surgeries had intraoperative CSF leaks that were repaired at the time of surgery. 11 of 47 (23%) surgeries had post-operative CSF leaks that required secondary operative repair. Clival chordomas had the highest CSF leak rate at 36%. There was no statistical difference in leak rate based on the type of reconstruction, although 28% of cases that used a vascularized flap had a post-operative leak, whereas only 9% of those cases not using a vascularized flap had a leak. Post-operative hydrocephalus and perioperative use of a lumbar drain were not significant risk factors. Pediatric patients with an intra-operative CSF leak during EES of the skull base have a high rate of post-operative CSF leaks. Clival chordomas appear to be a particularly high-risk group. The use of vascularized flaps and perioperative lumbar drains did not statistically decrease the rate of post-operative CSF leak. Copyright © 2017 Elsevier B.V. All rights reserved.
Outcomes of endoscopic repair of cerebrospinal fluid rhinorrhea without lumbar drains.
Adams, Austin S; Russell, Paul T; Duncavage, James A; Chandra, Rakesh K; Turner, Justin H
2016-11-01
Lumbar drains (LD) are commonly used during endoscopic repair of cerebrospinal fluid (CSF) rhinorrhea, either to facilitate graft healing or to monitor CSF fluid dynamics. However, the indications and necessity of LD placement remains controversial. The current study sought to evaluate endoscopic CSF leak repair outcomes in the setting of limited LD use. Patients who underwent endoscopic repair of CSF rhinorrhea between 2004 and 2014 were identified by a review of medical records. Demographic and clinical data were extracted and compared between patients who had surgery with and patients who had surgery without a perioperative LD. A univariate analysis was performed to identify factors predictive of recurrence. A total of 107 patients (116 surgical procedures) were identified, with a mean follow-up of 15.8 months. Eighty-eight of 107 patients (82.2%) had surgery without an LD. The mean hospital stay was 4.48 days in the LD group versus 1.03 days in the non-LD group (p < 0.00001). There was no difference in recurrence rate between the LD and non-LD groups. Predictors of recurrence included repair technique (p = 0.04) and size of defect (p = 0.005). Body mass index, leak site (ethmoid, sphenoid, frontal), and etiology (spontaneous, iatrogenic, traumatic) were not predictive of leak recurrence. Use of LDs in endoscopic CSF leak repair was not associated with reduced recurrence rates, regardless of leak etiology, and resulted in a significant increase in hospital length of stay. Although the use of perioperative LDs to monitor CSF dynamics may have some therapeutic and diagnostic advantages, it may not be associated with clinically significant improvements in patient outcomes or recurrence rates.
Archer, Jacob B; Sun, Hai; Bonney, Phillip A; Zhao, Yan Daniel; Hiebert, Jared C; Sanclement, Jose A; Little, Andrew S; Sughrue, Michael E; Theodore, Nicholas; James, Jeffrey; Safavi-Abbasi, Sam
2016-03-01
This article introduces a classification scheme for extensive traumatic anterior skull base fracture to help stratify surgical treatment options. The authors describe their multilayer repair technique for cerebrospinal fluid (CSF) leak resulting from extensive anterior skull base fracture using a combination of laterally pediculated temporalis fascial-pericranial, nasoseptal-pericranial, and anterior pericranial flaps. Retrospective chart review identified patients treated surgically between January 2004 and May 2014 for anterior skull base fractures with CSF fistulas. All patients were treated with bifrontal craniotomy and received pedicled tissue flaps. Cases were classified according to the extent of fracture: Class I (frontal bone/sinus involvement only); Class II (extent of involvement to ethmoid cribriform plate); and Class III (extent of involvement to sphenoid bone/sinus). Surgical repair techniques were tailored to the types of fractures. Patients were assessed for CSF leak at follow-up. The Fisher exact test was applied to investigate whether the repair techniques were associated with persistent postoperative CSF leak. Forty-three patients were identified in this series. Thirty-seven (86%) were male. The patients' mean age was 33 years (range 11-79 years). The mean overall length of follow-up was 14 months (range 5-45 months). Six fractures were classified as Class I, 8 as Class II, and 29 as Class III. The anterior pericranial flap alone was used in 33 patients (77%). Multiple flaps were used in 10 patients (3 salvage) (28%)--1 with Class II and 9 with Class III fractures. Five (17%) of the 30 patients with Class II or III fractures who received only a single anterior pericranial flap had persistent CSF leak (p < 0.31). No CSF leak was found in patients who received multiple flaps. Although postoperative CSF leak occurred only in high-grade fractures with single anterior flap repair, this finding was not significant. Extensive anterior skull base fractures often require aggressive treatment to provide the greatest long-term functional and cosmetic benefits. Several vascularized tissue flaps can be used, either alone or in combination. Vascularized flaps are an ideal substrate for cranial base repair. Dual and triple flap techniques that combine the use of various anterior, lateral, and nasoseptal flaps allow for a comprehensive arsenal in multilayered skull base repair and salvage therapy for extensive and severe fractures.
Conger, Andrew; Zhao, Fan; Wang, Xiaowen; Eisenberg, Amalia; Griffiths, Chester; Esposito, Felice; Carrau, Ricardo L; Barkhoudarian, Garni; Kelly, Daniel F
2018-05-11
OBJECTIVE The authors previously described a graded approach to skull base repair following endonasal microscopic or endoscope-assisted tumor surgery. In this paper they review their experience with skull base reconstruction in the endoscopic era. METHODS A retrospective review of a single-institution endonasal endoscopic patient database (April 2010-April 2017) was undertaken. Intraoperative CSF leaks were graded based on size (grade 0 [no leak], 1, 2, or 3), and repair technique was documented across grades. The series was divided into 2 epochs based on implementation of a strict perioperative antibiotic protocol and more liberal use of permanent and/or temporary buttresses; repair failure rates and postoperative meningitis rates were assessed for the 2 epochs and compared. RESULTS In total, 551 operations were performed in 509 patients for parasellar pathology, including pituitary adenoma (66%), Rathke's cleft cyst (7%), meningioma (6%), craniopharyngioma (4%), and other (17%). Extended approaches were used in 41% of cases. There were 9 postoperative CSF leaks (1.6%) and 6 cases of meningitis (1.1%). Postoperative leak rates for all 551 operations by grade 0, 1, 2, and 3 were 0%, 1.9%, 3.1%, and 4.8%, respectively. Fat grafts were used in 33%, 84%, 97%, and 100% of grade 0, 1, 2, and 3 leaks, respectively. Pedicled mucosal flaps (78 total) were used in 2.6% of grade 0-2 leaks (combined) and 79.5% of grade 3 leaks (60 nasoseptal and 6 middle turbinate flaps). Nasoseptal flap usage was highest for craniopharyngioma operations (80%) and lowest for pituitary adenoma operations (2%). Two (3%) nasoseptal flaps failed. Contributing factors for the 9 repair failures were BMI ≥ 30 (7/9), lack of buttress (4/9), grade 3 leak (4/9), and postoperative vomiting (4/9). Comparison of the epochs showed that grade 1-3 repair failures decreased from 6/143 (4.1%) to 3/141 (2.1%) and grade 1-3 meningitis rates decreased from 5 (3.5%) to 1 (0.7%) (p = 0.08). Prophylactic lumbar CSF drainage was used in only 4 cases (< 1%), was associated with a higher meningitis rate in grades 1-3 (25% vs 2%), and was discontinued in 2012. Comparison of the 2 epochs showed increase buttress use in the second, with use of a permanent buttress in grade 1 and 3 leaks increasing from 13% to 55% and 32% to 76%, respectively (p < 0.001), and use of autologous septal/keel bone as a permanent buttress in grade 1, 2, and 3 leaks increasing from 15% to 51% (p < 0.001). CONCLUSIONS A graded approach to skull base repair after endonasal surgery remains valid in the endoscopic era. However, the technique has evolved significantly, with further reduction of postoperative CSF leak rates. These data suggest that buttresses are beneficial for repair of most grade 1 and 2 leaks and all grade 3 leaks. Similarly, pedicled flaps appear advantageous for grade 3 leaks, while CSF diversion may be unnecessary and a risk factor for meningitis. High BMI should prompt an aggressive multilayered repair strategy. Achieving repair failure and meningitis rates lower than 1% is a reasonable goal in endoscopic skull base tumor surgery.
Skull Base Cerebrospinal Fluid Leakage Control with a Fibrin-Based Composite Tissue Adhesive
Rock, Jack P.; Sierra, David H.; Castro-Moure, Frederico; Jiang, Feng
1996-01-01
Cerebrospinal fluid (CSF) leaks can be responsible for significant patient morbidity and mortality. While the majority of leaks induced after head trauma will seal without intervention, spontaneous or surgically-induced leaks often require operative repair. Many modifications on standard surgical technique are available for repair of CSF fistulae, but none assures adequate closure. We have studied the efficacy of a novel fibrin-based composite tissue adhesive (CTA) for closure of experimentally-induced CSF leaks in rats. Fistulae were created in two groups of animals. Two weeks after creation of the leaks, the animals were sacrificed and analyzed for persistence of leak. A 58% leakage rate was noted in the control group (n = 12), and no leaks were noted in the experimental group closed after application of CTA to the surgical defect followed by skin closure (n = 11). Comparing the control group to the experimental group, results were statistically significant (p = 0.015). These data suggest that CTA may be effective as an adjunct for the closure of CSF fistulae. ImagesFigure 2Figure 3 PMID:17170969
Mitchell, Bartley D; Verla, Terence; Reddy, Duemani; Winnegan, Lona; Omeis, Ibrahim
2016-04-01
Cerebrospinal fluid (CSF) leak during anterior cervical spine surgery can lead to complications, including wound breakdown, meningitis, headaches, need for lumbar drain, or additional surgery. These leaks can be difficult to manage given the limited field of view and lack of deep access. Herein, we describe 8 consecutive patients who underwent intraoperative repair of CSF leak, with no postoperative evidence of wound dehiscence or drainage. A retrospective review was performed on 8 cases where CSF leak was encountered during an anterior cervical spine surgery. Patients had ossification of the posterior longitudinal ligament, intradural disk herniation, or dural ectasia. Intraoperative repair was as follows. First, CSF was drained to low pressure, and durotomy was covered by dural substitute and sealant agent. Then the interbody graft used was manually undersized in the anteroposterior dimension to allow for expansion of the agents used. Anterior instrumentation was then performed. Finally, a wound drain was anchored to a biologic bag for shoulder level passive drainage. In all 8 cases, there were no cases of wound dehiscence or CSF leak using this strategy. Likewise, there was no evidence of cord compression or neurologic deficits. No meningitis or persistent headaches were reported, and there was no need for lumbar drain placement at any time postoperatively. Once durotomy is encountered during anterior spine surgery, draining the CSF to a low pressure followed by dural substitute with a sealing agent, followed by a smaller anteroposterior size graft is an effective strategy of preventing complications in an inescapable problem. Copyright © 2016 Elsevier Inc. All rights reserved.
Raza, Shaan M; Banu, Matei A; Donaldson, Angela; Patel, Kunal S; Anand, Vijay K; Schwartz, Theodore H
2016-03-01
The intraoperative detection of CSF leaks during endonasal endoscopic skull base surgery is critical to preventing postoperative CSF leaks. Intrathecal fluorescein (ITF) has been used at varying doses to aid in the detection of intraoperative CSF leaks. However, the sensitivity and specificity of ITF at certain dosages is unknown. A prospective database of all endoscopic endonasal procedures was reviewed. All patients received 25 mg ITF diluted in 10 ml CSF and were pretreated with dexamethasone and Benadryl. Immediately after surgery, the operating surgeon prospectively noted if there was an intraoperative CSF leak and fluorescein was identified. The sensitivity, specificity, and positive and negative predictive power of ITF for detecting intraoperative CSF leak were calculated. Factors correlating with postoperative CSF leak were determined. Of 419 patients, 35.8% of patients did not show a CSF leak. Fluorescein-tinted CSF (true positive) was noted in 59.7% of patients and 0 false positives were encountered. CSF without fluorescein staining (false negative) was noted in 4.5% of patients. The sensitivity and specificity of ITF were 92.9% and 100%, respectively. The negative and positive predictive values were 88.8% and 100%, respectively. Postoperative CSF leaks only occurred in true positives at a rate of 2.8%. ITF is extremely specific and very sensitive for detecting intraoperative CSF leaks. Although false negatives can occur, these patients do not appear to be at risk for postoperative CSF leak. The use of ITF may help surgeons prevent postoperative CSF leaks by intraoperatively detecting and confirming a watertight repair.
Craven, Claudia; Toma, Ahmed K; Khan, Akbar A; Watkins, Laurence D
2016-09-01
Cerebrospinal fluid (CSF) leak following spinal surgery is a relatively common surgical complication. A disturbance in the underlying CSF dynamics could be the causative factor in a small group of patients with refractory CSF leaks that require multiple surgical repairs and prolonged hospital admission. A retrospective case series of patients with persistent post spinal surgery CSF leak referred to the hydrocephalus service for continuous intracranial pressure (ICP) monitoring. Patients' notes were reviewed for medical history, ICP data, radiological data, and subsequent management and outcome. Five patients (two males/three females, mean age, 35.4 years) were referred for ICP monitoring over a 12-month period. These patients had prolonged CSF leak despite multiple repair attempts 252 ± 454 days (mean ± SD). On ICP monitoring, all five patients had abnormal results, with the mean ICP 8.95 ± 4.41 mmHg. Four had abnormal pulse amplitudes, mean 6.15 mmHg ± 1.22 mmHg. All five patients underwent an intervention. Three patients underwent insertion of ventriculoperitoneal (VP) shunts. One patient had venous sinus stent insertion and one patient underwent medical management with acetazolamide. All five of the patients' CSF leak resolved post intervention. The mean time to resolution of CSF leak post intervention was 10.8 ± 12.9 days. Abnormal cerebrospinal fluid dynamics could be the underlying factor in patients with a persistent and treatment-refractory CSF leak post spinal surgery. Treatments aimed at lowering ICP may be beneficial in this group of patients. Whether abnormal pressure and dynamics represent a pre-existing abnormality or is induced by spinal surgery should be a subject of further study.
Nallet, E; Decq, P; Bezzo, A; Le Lievre, G; Peynegre, R; Coste, A
1998-10-01
The incidence and the risk of meningitidis justify treatment in all cases of cerebrospinal fluid rhinorrhea with spontaneous etiology or after traumatic injury. Endonasal surgery with endoscopic instruments provides many advantages compared with transcranial or transfacial approach used by neurosurgeons. We report our experience and our surgical technique in the treatment of CSF leaks in 5 patients. Intrathecal injection of fluoresceine was very useful in all cases for detecting the CSF leak. Total or selected ethmoidectomy depended on the localization of the leakage. Wide sphenoidotomy enables detection and repair of CSF leaks from the sphenoid cavity. A free graft of inferior turbinal mucosal was used to repair the breache. This rapid low morbidity surgery offered secure closure of rhinorrhea in 4 cases after one procedure and in 1 case after two procedures with an average follow up of 22 months. Cerebrospinal fluid rhinorrhea can be managed in first line therapy with endoscopic intranasal surgical techniques when they are localized in the anterior ethmoid or in the sphenoid cavity.
Vanishing calcification associated with a spontaneous ventral spinal cerebrospinal fluid leak.
Schievink, Wouter I; Ross, Lindsey; Prasad, Ravi S; Maya, M Marcel
2016-12-01
Some patients with spontaneous intracranial hypotension have a ventral spinal cerebrospinal fluid (CSF) leak and these CSF leaks may be associated with calcified disk herniations. Identifying these calcifications is helpful in directing treatment. We report here the unusual case of a patient with a ventral CSF leak in whom the associated calcification absorbed over a five-month period. A 42-year-old woman developed orthostatic headaches and bilateral abducens nerve palsies. Magnetic resonance imaging of her brain showed typical findings of spontaneous intracranial hypotension. Magnetic resonance imaging of her spine showed an extensive cervicothoracic CSF leak. Computed tomographic myelography showed calcification at the Th1-2 disk space. Three epidural blood patches were performed, but her symptoms persisted. Digital subtraction myelography performed five months later showed an upper thoracic ventral CSF, but the calcification was no longer present. A dural tear, found at surgery at the Th1-2 level, was repaired and the patient made an uneventful recovery. The resorption of calcifications at the level of a ventral spinal CSF leak could explain the absence of any calcifications in at least some patients with such leaks and demonstrates the usefulness of reviewing previous imaging in patients with ventral CSF leaks if the exact site of the leak remains unknown. © International Headache Society 2016.
Ling, Phoebe Y; Mendelson, Zachary S; Reddy, Rohit K; Jyung, Robert W; Liu, James K
2014-10-01
Postoperative cerebrospinal fluid (CSF) leaks and headaches remain potential complications after retrosigmoid approaches for lesions in the posterior fossa and cerebellopontine angle. The authors describe a simple repair technique with an autologous fat graft-assisted Medpor Titan cranioplasty and investigate the incidence of postoperative CSF leaks and headaches using this technique. A retrospective chart review was conducted on all cases (n = 60) of retrosigmoid craniectomy from September 2009 to May 2014 in patients who underwent fat graft-assisted cranioplasty. After obtaining a watertight dural closure and sealing off any visible mastoid air cells with bone wax, an autologous fat graft was placed over the dural suture line and up against the waxed-off air cells. The fat graft filled the retrosigmoid cranial defect and was then bolstered with a Medpor Titan (titanium mesh embedded in porous polyethylene) cranioplasty. A postoperative mastoid pressure dressing was applied for 48 h, and prophylactic lumbar drainage was not used. Factors examined in this study included postoperative CSF leak (incisional, rhinorrhea, otorrhea), pseudomeningocele formation, incidence and severity of postoperative headache, length of hospital stay, and length of follow-up. No patients developed postoperative CSF leaks (0 %), pseudomeningoceles (0 %), or new-onset postoperative headaches (0 %) with the described repair technique. There were no cases of graft site morbidity such as hematoma or wound infection. Mean duration of postoperative hospital stay was 3.8 days (range 2-10 days). Mean postoperative follow-up was 12.4 months (range 2.0-41.1 months). Our multilayer repair technique with a fat graft-assisted Medpor Titan cranioplasty appears effective in preventing postoperative CSF leaks and new-onset postoperative headaches after retrosigmoid approaches. Postoperative lumbar drainage may not be necessary.
Zhang, C; Ding, X; Lu, Y; Hu, L; Hu, G
2017-08-01
The aim of this study was to elucidate the risk factors for cerebrospinal fluid (CSF) rhinorrhoea following transsphenoidal surgery and discuss its prevention and treatments. We retrospectively reviewed 474 consecutive cases of pituitary adenoma treated with 485 transsphenoidal surgical procedures from January 2008 to December 2011 in our department. We analysed the incidence of intra- and post-operative CSF leakage and outcomes of various repair strategies. Intra-operative CSF leakage was encountered in 85 cases (17.9%), and post-operative CSF rhinorrhoea in 13 cases (2.7%). Seven of the 13 patients with post-operative CSF rhinorrhoea did not experience intra-operative CSF leakage; three of these patients had adrenocorticotropic hormone-secreting adenomas. Of the remaining 6 patients with both intra- and post-operative CSF leakage, 2 were treated for giant invasive prolactinomas, and 2 had previously undergone transsphenoidal surgery. In eight patients, the leak was resolved by lumbar puncture, lumbar external drainage, resting in a semi-reclining position, or other conservative treatment. Two CSF leaks were repaired with gelatine foam and fibrin glue using a transsphenoidal approach, and two with autologous fat graft and sellar floor reconstruction using a transnasal endoscopic approach. After undergoing two transnasal endoscopic repairs, one patient with post-operative CSF rhinorrhoea was successfully treated by further lumbar subarachnoid drainage. In conclusion, procedures using gelatine foam, fibrin glue and autologous fat graft are common and effective techniques for the management of CSF rhinorrhoea after transsphenoidal surgery. When a CSF leak is detected during transsphenoidal surgery, thorough sellar reconstruction and long-term follow-up are necessary. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.
Altuna, Xabier; Navarro, Juan José; García, Leire; Ugarte, Ane; Thomas, Izaskun
Spontaneous cerebrospinal fluid (CSF) leaks to the middle ear due to tegmen tympani defects can result in hearing loss or hypoacusis and predispose to meningitis as well as other neurological complications. Surgical repair of the defect can be performed through a middle cranial fossa (MCF) approach or a transmastoid approach. We conducted a retrospective study of the patients in our Department due to a spontaneous CSF leak to the middle ear treated using a MCF approach during a 6-year period (2009-2014). Thirteen patients with spontaneous CSF leak to the middle ear were treated with this approach. The primary and first symptom in all of them was conductive hearing loss. In all cases, the defect or defects were closed in a multilayer manner using muscle, temporalis fascia and cortical bone. Minimum follow-up in this series was 14 months, with successful closure in all but one patient (who required reintervention). We found no intra- or postoperative complications due to the craniotomy, and the audiometry improved and normalised in all cases except for the failed case. The MCF approach with a multilayer closure of the defect is an effective technique for repairing spontaneous CSF leaks to the middle ear and for restoring hearing in these patients. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Endoscopic Removal of a Bullet in Rosenmuller Fossa: Case Report
Burks, Joshua D.; Glenn, Chad A.; Conner, Andrew K.; Bonney, Phillip A.; Sanclement, Jose A.; Sughrue, Michael E.
2016-01-01
Fractures of the anterior skull base may occur in gunshot victims and can result in traumatic cerebrospinal fluid (CSF) leak. Less commonly, CSF leaks occur days or even weeks after the trauma occurred. Here, we present the case of a 21-year-old man with a delayed-onset, traumatic CSF leak secondary to a missile injury that left a bullet fragment in the Rosenmuller fossa. The patient was treated successfully with endoscopic, endonasal extraction of the bullet, and repair with a nasal septal flap. Foreign bodies lodged in Rosenmuller fossa can be successfully treated with endoscopic skull base surgery. PMID:27330924
Treatment of cerebrospinal fluid leak after spine surgery.
Fang, Zhao; Tian, Rong; Jia, Yu-Tao; Xu, Tian-Tong; Liu, Yang
2017-04-01
Owing to the complexity of spinal surgery, there is a great prevalence of dural tear causing cerebrospinal fluid (CSF) leakage. Many studies focused on suture repair for dural tear to stop CSF leak. Now some new treatment strategies have shown a promising effect that is listed as follows: 1) creating watertight dural closure to stop CSF leak with the help of dural substitute material; and 2) retarding CSF leak by changing pressure difference, including reducing the subarachnoid fluid pressure, increasing the epidural space pressure and both. In fact several methods mentioned above are usually combined to treat CSF leak. However, no update review summarized the relevant studies implemented in recent years. In this review, the authors would compare the effects of different dural closure techniques, and introduce the latest treatment methods and mechanisms. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.
The Management of Cerebrospinal Fluid Leak After Anterior Cervical Decompression Surgery.
Zhai, Jiliang; Panchal, Ripul R; Tian, Ye; Wang, Shujie; Zhao, Lijuan
2018-03-01
Cerebrospinal fluid (CSF) leak is a rare but potentially troublesome and occasionally catastrophic complication after anterior cervical decompression surgery. There is limited literature describing this complication, and the management of CSF leak varies. The aim of this study was to retrospectively review the treatment of cases with CSF leak and develop a management algorithm. A series of 14 patients with CSF leak from January 2011 to May 2016 were included in this study. Their characteristics, management of CSF leak, and outcomes were documented. There were 5 male and 9 female patients. Mean age at surgery was 57.1±9.9 years (range, 37-76 years). All instances of CSF leak, except 1 noted postoperatively, were indirectly repaired intraoperatively. A closed straight wound drain was placed for all patients. A lumbar subarachnoid drain was placed immediately after surgery in 4 patients and postoperatively in 7 patients. In 1 patient, lumbar drain placement was unsuccessful. In 2 additional patients, the surgeon decided not to place a lumbar drain. One patient developed meningitis and recovered after antibiotic therapy with meropenem and vancomycin. Another patient had a deep wound infection and required a revision surgery. Wound drains and lumbar drains should be immediately considered when CSF leak is identified. Antibiotics also should be considered to prevent intradural infection. [Orthopedics. 2018; 41(2):e283-e288.]. Copyright 2018, SLACK Incorporated.
Modified Graded Repair of Cerebrospinal Fluid Leaks in Endoscopic Endonasal Transsphenoidal Surgery
Park, Jae-Hyun; Choi, Jai Ho; Kim, Young-Il; Kim, Sung Won
2015-01-01
Objective Complete sellar floor reconstruction is critical to avoid postoperative cerebrospinal fluid (CSF) leakage during transsphenoidal surgery. Recently, the pedicled nasoseptal flap has undergone many modifications and eventually proved to be valuable and efficient. However, using these nasoseptal flaps in all patients who undergo transsphenoidal surgery, including those who had none or only minor CSF leakage, appears to be overly invasive and time-consuming. Methods Patients undergoing endoscopic endonasal transsphenoidal tumor surgery within a 5 year-period were reviewed. Since 2009, we classified the intraoperative CSF leakage into grades from 0 to 3. Sellar floor reconstruction was tailored to each leak grade. We did not use any tissue grafts such as abdominal fat and did not include any procedures of CSF diversions such as lumbar drainage. Results Among 200 cases in 188 patients (147 pituitary adenoma and 41 other pathologies), intraoperative CSF leakage was observed in 27.4% of 197 cases : 14.7% Grade 1, 4.6% Grade 2a, 3.0% Grade 2b, and 5.1% Grade 3. Postoperative CSF leakage was observed in none of the cases. Septal bone buttress was used for Grade 1 to 3 leakages instead of any other foreign materials. Pedicled nasoseptal flap was used for Grades 2b and 3 leakages. Unused septal bones and nasoseptal flaps were repositioned. Conclusion Modified classification of intraoperative CSF leaks and tailored repair technique in a multilayered fashion using an en-bloc harvested septal bone and vascularized nasoseptal flaps is an effective and reliable method for the prevention of postoperative CSF leaks. PMID:26279811
Endoscopic Repair of CSF Fistulae: A Ten Year Experience
Alexander, Arun; Mathew, John; Varghese, Ajoy Mathew
2016-01-01
Introduction Cerebrospinal Fluid (CFF) fistulae are repaired endoscopically with varying degrees of success around the world. Large series are still uncommon, and the results varied primarily because of the different techniques by different surgeons and also because of a variation in the patient profile in each series, for example, many series deal primarily with traumatic CSF leaks where the defects are larger and outcomes poorer. Aim To analyse the surgical outcomes of Endoscopic CSF rhinorrhea closure. Materials and Methods This is a series of 34 cases operated upon primarily by one surgeon in two different centres over a period of 10 years. Results Of the 34 cases, 76% of the patients were women. Among the patients only 20.6% patients had a history of trauma preceding the CSF leak. The most common site of leak was in the fovea ethmoidalis in 19 (55.8%) followed by 10 (29.4%) in the cribriform plate. An overlay technique of placing the multiple layers of fascia and mucosa was used in 26 (76.5%) patients and underlay technique in the remaining. Postoperative lumbar drain was used in all patients. Conclusion Based on the treatment outcome of the 34 patients, it can be concluded that the success rate of a single endoscopic procedure in our experience is 97% and 100% following the second. Endoscopic approach for closure of CSF leak is safe with minimal complications and little morbidity. PMID:27656471
Early harvesting of the vascularized pedicled nasoseptal flap during endoscopic skull base surgery.
Eloy, Jean Anderson; Patel, Amit A; Shukla, Pratik A; Choudhry, Osamah J; Liu, James K
2013-01-01
The vascularized pedicled nasoseptal flap (PNSF) represents a successful option for reconstruction of large skull base defects after expanded endoscopic endonasal approaches (EEA). This vascularized flap can be harvested early or late in the operation depending on the anticipation of high-flow CSF leaks. Each harvesting technique (early vs. late) is associated with different advantages and disadvantages. In this study, we evaluate our experience with early harvesting of the PNSF for repair of large skull base defects after EEA. A retrospective review was performed at a tertiary care medical center on patients who underwent early PNSF harvesting during reconstruction of intraoperative high-flow CSF leaks after EEA between December 2008 and March 2012. Demographic data, repair materials, surgical approach, and incidence of PNSF usage were collected. Eighty-seven patients meeting the inclusion criteria were identified. In 86 procedures (98.9%), the PNSF harvested at the beginning of the operation was used. In 1 case (1.1%), the PNSF was not used because a high-flow intraoperative CSF leak was not encountered. This patient had recurrence of intradural disease 8months later, and the previously elevated PNSF was subsequent used after tumor resection. Based on our data, a high-flow CSF leak and need for a PNSF can be accurately anticipated in patients undergoing EEA for skull base lesions. Because of the advantages of early harvesting of the PNSF and the high preoperative predictive value of CSF leak anticipations, this technique represents a feasible harvesting practice for EEA surgeries. Copyright © 2013 Elsevier Inc. All rights reserved.
Morbidity of repeat transsphenoidal surgery assessed in more than 1000 operations.
Jahangiri, Arman; Wagner, Jeffrey; Han, Sung Won; Zygourakis, Corinna C; Han, Seunggu J; Tran, Mai T; Miller, Liane M; Tom, Maxwell W; Kunwar, Sandeep; Blevins, Lewis S; Aghi, Manish K
2014-07-01
OBJECT.: While transsphenoidal surgery is associated with low morbidity, the degree to which morbidity increases after reoperation remains unclear. The authors determined the morbidity associated with repeat versus initial transsphenoidal surgery after 1015 consecutive operations. The authors conducted a 5-year retrospective review of the first 916 patients undergoing transsphenoidal surgery at their institution after a pituitary center of expertise was established, and they analyzed morbidities. The authors analyzed 907 initial and 108 repeat transsphenoidal surgeries performed in 916 patients (9 initial surgeries performed outside the authors' center were excluded). The most common diagnoses were endocrine inactive (30%) or active (36%) adenomas, Rathke's cleft cysts (10%), and craniopharyngioma (3%). Morbidity of initial surgery versus reoperation included diabetes insipidus ([DI] 16% vs 26%; p = 0.03), postoperative hyponatremia (20% vs 16%; p = 0.3), new postoperative hypopituitarism (5% vs 8%; p = 0.3), CSF leak requiring repair (1% vs 4%; p = 0.04), meningitis (0.4% vs 3%; p = 0.02), and length of stay ([LOS] 2.8 vs 4.5 days; p = 0.006). Of intraoperative parameters and postoperative morbidities, 1) some (use of lumbar drain and new postoperative hypopituitarism) did not increase with second or subsequent reoperations (p = 0.3-0.9); 2) some (DI and meningitis) increased upon second surgery (p = 0.02-0.04) but did not continue to increase for subsequent reoperations (p = 0.3-0.9); 3) some (LOS) increased upon second surgery and increased again for subsequent reoperations (p < 0.001); and 4) some (postoperative hyponatremia and CSF leak requiring repair) did not increase upon second surgery (p = 0.3) but went on to increase upon subsequent reoperations (p = 0.001-0.02). Multivariate analysis revealed that operation number, but not sex, age, pathology, radiation therapy, or lesion size, increased the risk of CSF leak, meningitis, and increased LOS. Separate analysis of initial versus repeat transsphenoidal surgery on the 2 most common benign pituitary lesions, pituitary adenomas and Rathke's cleft cysts, revealed that the increased incidence of DI and CSF leak requiring repair seen when all pathologies were combined remained significant when analyzing only pituitary adenomas and Rathke's cleft cysts (DI, 13% vs 35% [p = 0.001]; and CSF leak, 0.3% vs 9% [p = 0.0009]). Repeat transsphenoidal surgery was associated with somewhat more frequent postoperative DI, meningitis, CSF leak requiring repair, and greater LOS than the low morbidity characterizing initial transsphenoidal surgery. These results provide a framework for neurosurgeons in discussing reoperation for pituitary disease with their patients.
Pedicled Extranasal Flaps in Skull Base Reconstruction
Kim, Grace G.; Hang, Anna X.; Mitchell, Candace; Zanation, Adam M.
2013-01-01
Cerebrospinal fluid (CSF) leaks most commonly arise during or after skull base surgery, although they occasionally present spontaneously. Recent advances in the repair of CSF leaks have enabled endoscopic endonasal surgery to become the preferred option for management of skull base pathology. Small defects (<1cm) can be repaired by multilayered free grafts. For large defects (>3cm), pedicled vascular flaps are the repair method of choice, resulting in much lower rates of postoperative CSF leaks. The pedicled nasoseptal flap (NSF) constitutes the primary reconstructive option for the vast majority of skull base defects. It has a large area of potential coverage and high rates of success. However, preoperative planning is required to avoid sacrificing the NSF during resection. In cases where the NSF is unavailable, often due to tumor involvement of the septum or previous resection removing or compromising the flap, other flaps may be considered. These flaps include intranasal options—inferior turbinate (IT) or middle turbinate (MT) flaps—as well as regional pedicled flaps: pericranial flap (PCF), temporoparietal fascial flap (TPFF), or palatal flap (PF). More recently, novel alternatives such as the pedicled facial buccinator flap (FAB) and the pedicled occipital galeopericranial flap (OGP) have been added to the arsenal of options for skull base reconstruction. Characteristics of and appropriate uses for each flap are described. PMID:23257554
Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.
Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz
2015-06-01
The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.
Combined use of fibrin tissue adhesive and acellular dermis in dural repair.
Shah, Anil R; Pearlman, Aaron N; O'Grady, Kevin M; Bhattacharyya, Tappan K; Toriumi, Dean M
2007-01-01
The management of cerebrospinal fluid (CSF) leaks can be challenging. Acellular dermal grafts derived from human cadavers can be used as a replacement material when autogenous materials are unavailable. Fibrin tissue adhesive (FTA) is a wound support product that has been used for hemostatic and tissue fixation purposes. The combined use of acellular dermis in conjunction with FTA for dural repair remains a subject of study. The aim of this study was to evaluate wound healing and tissue compatibility characteristics of acellular dermal substitute material when used both with and without FTA, for repair of a dural tear in a chinchilla model. Forty-nine chinchillas were included in this randomized case-control study. The squamous portion of the temporal bone was removed to expose the tegmen. A 2 x 2 mm dural defect was removed to create an iatrogenic CSF leak. Then, animals were randomly assigned to one of three treatment groups: group 1, acellular dermis alone; group 2, acellular dermis with FTA; group 3, fibrinogen, acellular dermis, and FTA. Surgical sites were examined grossly at 1- and 2-week intervals. Temporal bones were examined histologically. Grossly, groups 2 and 3 had significantly less visible CSF leak and brain herniation noted at both 1- and 2-week intervals when compared with group 1. Histological results confirmed the gross results showing the best seal in group 2 and 3. Acellular dermis combined with FTA provided superior support compared with acellular dermis alone in repair of induced dural defects.
[Endoscopic endonasal detection of cerebrospinal fluid leakage with topical fluorescein].
Sato, Taku; Kishida, Yugo; Watanabe, Tadashi; Tani, Akiko; Tada, Yasuhiro; Tamura, Takamitsu; Ichikawa, Masahiro; Sakuma, Jun; Omori, Koichi; Saito, Kiyoshi
2013-08-01
We evaluated the effectiveness of intraoperative topical application of fluorescein to detect the leakage point of cerebrospinal fluid(CSF)rhinorrhea. Three patients with CSF rhinorrhea were treated with an endoscopic endonasal technique. Ten percent fluorescein was topically used for intraoperative localization of the leak site. A change of the fluorescein color from brown to green due to dilation of CSF were recognized as evidence of CSF rhinorrhea. We repeated the procedure to detect any small defects. All CSF rhinorrheas were successfully repaired by this endoscopic endonasal approach. Topical application of fluorescein is simple and sensitive for identifying intraoperative CSF rhinorrhea.
Transmastoid approach to temporal bone cerebrospinal fluid leaks.
Oliaei, Sepehr; Mahboubi, Hossein; Djalilian, Hamid R
2012-01-01
The aim of the study was to evaluate various presentations and treatment options for spontaneous cerebrospinal fluid (CSF) leakage originating in the temporal bone. Clinical data and imaging results for 18 ears (15 patients) presenting with spontaneous CSF leakage originating in the temporal bone were reviewed. Average follow-up period was 13.5 months. The main outcome measure was presence of persistent CSF leak postoperatively. A standard postauricular mastoidectomy was performed. Fifteen patients diagnosed with spontaneous CSF leakage over an 8-year period including 3 treated for bilateral disease were included in the study. The age ranged between 33 and 83 years. Presenting symptoms included serous otitis media (44%), persistent otorrhea after tympanostomy tube placement (28%), and meningitis (28%). Preoperative diagnosis was made using imaging studies and was substantiated by observation of CSF leakage and dural herniation intraoperatively. Treatment was eustachian tube plugging (5%), mastoidectomy with fat obliteration (61%), middle fossa approach with extradural (17%), intradural repair (5%), or combined middle fossa and transmastoid (TM) approach (11%). Successful treatment was obtained in 17 of the 18 cases. The last 9 patients in the series underwent TM approach alone for repair with no treatment failures. Repair of defects in tegmen mastoideum and posterior fossa can be successfully achieved on an outpatient basis without regard to size and multitude of defects via TM approach. This approach obviates the need for a craniotomy or lumbar drain. Copyright © 2012 Elsevier Inc. All rights reserved.
Repair of Spontaneous Cerebrospinal Fluid Otorrhea from Defect of Middle Cranial Fossa
Goh, Young Bum; Han, Chi-Sung
2013-01-01
Spontaneous cerebrospinal fluid (CSF) otorrhea is defined as CSF otorrhea where there are no identifiable causes including previous trauma, surgery, infection, neoplasm or congenital anomaly. The condition is rare. The origin of CSF leak is commonly a defect in the tegmen of the middle cranial fossa. The pathophysiology of spontaneous CSF otorrhea is unclear. Two theories of the etiology of bony defects of the temporal bone are the congenital bony defect theory and arachnoid granulation theory. The authors experienced a case of a 49-year-old female patient admitted with the complaint of persistent right ear fullness. Computed tomography revealed a large defect of the middle fossa and suspicious CSF otorrhea through the defect of tegmen tympani. Repair was successful with multiple bone chips using the transmastoid approach. The postoperative course was good and there has been no recurrence of the CSF leakage. PMID:24653924
... this makes symptoms go away. In rare cases, surgery is needed to repair the tear in the dura and stop the headache. If symptoms of infection ( fever , chills, change in mental status) are present, they need to be treated ...
Barger, James; Siow, Matthew; Kader, Michael; Phillips, Katherine; Fatterpekar, Girish; Kleinberg, David; Zagzag, David; Sen, Chandranath; Golfinos, John G.; Lebowitz, Richard; Placantonakis, Dimitris G.
2018-01-01
Background: While effective for the repair of large skull base defects, the Hadad-Bassagasteguy nasoseptal flap increases operative time and can result in a several-week period of postoperative crusting during re-mucosalization of the denuded nasal septum. Endoscopic transsphenoidal surgery for pituitary adenoma resection is generally not associated with large dural defects and high-flow cerebrospinal fluid (CSF) leaks requiring extensive reconstruction. Here, we present the posterior nasoseptal flap as a novel technique for closure of skull defects following endoscopic resection of pituitary adenomas. This flap is raised in all surgeries during the transnasal exposure using septal mucoperiosteum that would otherwise be discarded during the posterior septectomy performed in binostril approaches. Methods: We present a retrospective, consecutive case series of 43 patients undergoing endoscopic transsphenoidal resection of a pituitary adenoma followed by posterior nasoseptal flap placement and closure. Main outcome measures were extent of resection and postoperative CSF leak. Results: The mean extent of resection was 97.16 ± 1.03%. Radiographic measurement showed flap length to be adequate. While a defect in the diaphragma sellae and CSF leak were identified in 21 patients during surgery, postoperative CSF leak occurred in only one patient. Conclusions: The posterior nasoseptal flap provides adequate coverage of the surgical defect and is nearly always successful in preventing postoperative CSF leak following endoscopic transsphenoidal resection of pituitary adenomas. The flap is raised from mucoperiosteum lining the posterior nasal septum, which is otherwise resected during posterior septectomy. Because the anterior septal cartilage is not denuded, raising such flaps avoids the postoperative morbidity associated with the larger Hadad-Bassagasteguy nasoseptal flap. PMID:29527390
Oblique Intrathecal Injection in Lumbar Spine Surgery: A Technical Note.
Jewett, Gordon A E; Yavin, Daniel; Dhaliwal, Perry; Whittaker, Tara; Krupa, JoyAnne; Du Plessis, Stephan
2017-09-01
Intrathecal morphine (ITM) is an efficacious method of providing postoperative analgesia and reducing pain associated complications. Despite adoption in many surgical fields, ITM has yet to become a standard of care in lumbar spine surgery. Spine surgeons' reticence to make use of the technique may in part be attributed to concerns of precipitating a cerebrospinal fluid (CSF) leak. Herein we describe a method for oblique intrathecal injection during lumbar spine surgery to minimize risk of CSF leak. The dural sac is penetrated obliquely at a 30° angle to offset dural and arachnoid puncture sites. Oblique injection in instances of limited dural exposure is made possible by introducing a 60° bend to a standard 30-gauge needle. The technique was applied for injection of ITM or placebo in 104 cases of lumbar surgery in the setting of a randomized controlled trial. Injection was not performed in two cases (2/104, 1.9%) following preinjection dural tear. In the remaining 102 cases no instances of postoperative CSF leakage attributable to oblique intrathecal injection occurred. Three cases (3/102, 2.9%) of transient CSF leakage were observed immediately following intrathecal injection with no associated sequelae or requirement for postsurgical intervention. In two cases, the observed leak was repaired by sealing with fibrin glue, whereas in a single case the leak was self-limited requiring no intervention. Oblique dural puncture was not associated with increased incidence of postoperative CSF leakage. This safe and reliable method of delivery of ITM should therefore be routinely considered in lumbar spine surgery.
Aydin, K; Guven, K; Sencer, S; Jinkins, J R; Minareci, O
2004-01-01
Our purpose was to evaluate the utility of intrathecal gadopentetate dimeglumine -enhanced magnetic resonance cisternography (GdMRC). We injected 0.5 ml contrast medium into the subarachnoid space via lumbar puncture in 20 patients with suspected cerebrospinal fluid (CSF) rhinorrhoea. MRC showed CSF leakage in 14 patients with rhinorrhoea at the time of the examination, into the ethmoid air cells in nine, the sphenoid sinus in three and the frontal sinus in two cases. In 12 of these the site leakage was confirmed during surgical repair of the fistula. No leakage was observed in four patients with intermittent rhinorrhoea, not present at the time of the examination. GdMRC showed leakage in two patients with negative CT cisternography. GdMRC may prove better than CT cisternography, especially with slow CSF flow. We also showed low-dose GdMRC to be a feasible and relative safe way of confirming the presence of and localising active CSF leaks prior to surgical repair.
Park, Jaechan; Choi, Yeon-Ju; Ohk, Boram; Chang, Hyun-Ha
2018-01-01
The placement of a ventricular catheter for temporary cerebrospinal fluid (CSF) diversion is associated with a considerable risk of CSF infection. The authors investigated the effect of a CSF leak on CSF-related infection and the predisposing factors for a CSF leak. Fifty-two patients who underwent external ventricular drainage (EVD) for acute hydrocephalus associated with a subarachnoid hemorrhage or intraventricular hemorrhage (IVH) were enrolled in this prospective study. A CSF leak-detection paper (small sterilized filter paper) was applied at the percutaneous catheter exit site to check for any bloody CSF leak. In addition, radiologic and clinical data were collected. Four of the 52 patients (7.7%) developed an EVD-related CSF infection from organisms including Staphylococcus epidermidis (n = 3) and Staphylococcus hominis (n = 1). A prolonged CSF leak >1 day was detected in 9 patients (17.3%) and revealed as a significant risk factor for CSF infection with a 44.4% positive predictive value. Moreover, an IVH >10 mL was found in 11 patients (21.2%) and revealed as a significant predisposing factor for a CSF leak at the percutaneous catheter exit. A prolonged CSF leak for >1 day at the percutaneous catheter exit site is a crucial risk factor for EVD-related CSF infection and an IVH >10 mL is a predisposing factor for a CSF leak. Copyright © 2017 Elsevier Inc. All rights reserved.
Sensitivity of MRI of the spine compared with CT myelography in orthostatic headache with CSF leak.
Starling, Amaal; Hernandez, Fatima; Hoxworth, Joseph M; Trentman, Terrence; Halker, Rashmi; Vargas, Bert B; Hastriter, Eric; Dodick, David
2013-11-12
To investigate the sensitivity of MRI of the spine compared with CT myelography (CTM) in detecting CSF leaks. Between July 1998 and October 2010, 12 patients with orthostatic headache and a CTM-confirmed spinal CSF leak underwent an MRI of the spine with and without contrast. Using CTM as the gold standard, we retrospectively investigated the sensitivity of spinal MRI in detecting a CSF leak. Eleven of 12 patients with a CSF leak documented by CTM also had extradural fluid collections on spinal MRI (sensitivity 91.7%). Six patients with extradural fluid collections on spinal MRI also had spinal dural enhancement. When compared with the gold standard of CTM, MRI of the spine appears to be a sensitive and less invasive imaging modality for detecting a spinal CSF leak, suggesting that MRI of the spine should be the imaging modality of first choice for the detection of spinal CSF leaks.
Imaging review of cerebrospinal fluid leaks
Vemuri, Naga V; Karanam, Lakshmi S P; Manchikanti, Venkatesh; Dandamudi, Srinivas; Puvvada, Sampath K; Vemuri, Vineet K
2017-01-01
Cerebrospinal fluid (CSF) leak occurs due to a defect in the dura and skull base. Trauma remains the most common cause of CSF leak; however, a significant number of cases are iatrogenic, and result from a complication of functional endoscopic sinus surgery (FESS). Early diagnosis of CSF leak is of paramount importance to prevent life-threatening complications such as brain abscess and meningitis. Imaging plays a crucial role in the detection and characterization of CSF leaks. Three-dimensional, isotropic, high resolution computed tomography (HRCT) accurately detects the site and size of the bony defect. CT cisternography, though invasive, helps accurately identify the site of CSF leak, especially in the presence of multiple bony defects. Magnetic resonance imaging (MRI) accurately detects CSF leaks and associated complications such as the encephaloceles and meningoceles. In this review, we emphasize the importance and usefulness of 3D T2 DRIVE MR cisternography in localizing CSF leaks. This sequence has the advantages of effective bone and fat suppression, decreased artefacts, faster acquisition times, three-dimensional capability, y and high spatial resolution in addition to providing very bright signal from the CSF. PMID:29379240
Imaging review of cerebrospinal fluid leaks.
Vemuri, Naga V; Karanam, Lakshmi S P; Manchikanti, Venkatesh; Dandamudi, Srinivas; Puvvada, Sampath K; Vemuri, Vineet K
2017-01-01
Cerebrospinal fluid (CSF) leak occurs due to a defect in the dura and skull base. Trauma remains the most common cause of CSF leak; however, a significant number of cases are iatrogenic, and result from a complication of functional endoscopic sinus surgery (FESS). Early diagnosis of CSF leak is of paramount importance to prevent life-threatening complications such as brain abscess and meningitis. Imaging plays a crucial role in the detection and characterization of CSF leaks. Three-dimensional, isotropic, high resolution computed tomography (HRCT) accurately detects the site and size of the bony defect. CT cisternography, though invasive, helps accurately identify the site of CSF leak, especially in the presence of multiple bony defects. Magnetic resonance imaging (MRI) accurately detects CSF leaks and associated complications such as the encephaloceles and meningoceles. In this review, we emphasize the importance and usefulness of 3D T2 DRIVE MR cisternography in localizing CSF leaks. This sequence has the advantages of effective bone and fat suppression, decreased artefacts, faster acquisition times, three-dimensional capability, y and high spatial resolution in addition to providing very bright signal from the CSF.
Tumturk, Abdulfettah; Ulutabanca, Halil; Gokoglu, Abdulkerim; Oral, Sukru; Menku, Ahmet; Kurtsoy, Ali
2016-01-01
To share the results of conventional surgery in rhinorrhea and the contribution of computerized tomography (CT) cisternography to determination of the site of cerebrospinal fluid (CSF) leak. Twelve cases treated for spontaneous rhinorrhea were included in this study. All the cases underwent cranial CT and magnetic resonance imaging (MRI). CT cisternography was performed in four patients whose bone defect or leakage site could not be detected by CT and MRI. In order to repair the defect, either the galea or galea together with collagen matrix was used and the procedure was supported with fibrin glue. In the cases, postoperative rhinorrhea was seen in neither the early nor the late follow up period. We observed no complications related to CT cisternography or craniotomy. The leakage area was successfully detected with CT cisternography when the other methods failed. Bone defect can usually be shown by means of CT. However, when bone-defect cannot be shown or the dura in the defective area is intact, CT cisternography is useful to show the CSF leak. Conventional surgery was very succesful in the treatment of spontaneous rhinorrhea but it was cosmetically problematic. In the patients both treated with galea and galea together with collagen matrix, the repair of the defect was successful.
Schievink, Wouter I; Schwartz, Marc S; Maya, M Marcel; Moser, Franklin G; Rozen, Todd D
2012-04-01
Spontaneous intracranial hypotension is an important cause of headaches and an underlying spinal CSF leak can be demonstrated in most patients. Whether CSF leaks at the level of the skull base can cause spontaneous intracranial hypotension remains a matter of controversy. The authors' aim was to examine the frequency of skull base CSF leaks as the cause of spontaneous intracranial hypotension. Demographic, clinical, and radiological data were collected from a consecutive group of patients evaluated for spontaneous intracranial hypotension during a 9-year period. Among 273 patients who met the diagnostic criteria for spontaneous intracranial hypotension and 42 who did not, not a single instance of CSF leak at the skull base was encountered. Clear nasal drainage was reported by 41 patients, but a diagnosis of CSF rhinorrhea could not be established. Four patients underwent exploratory surgery for presumed CSF rhinorrhea. In addition, the authors treated 3 patients who had a postoperative CSF leak at the skull base following the resection of a cerebellopontine angle tumor and developed orthostatic headaches; spinal imaging, however, demonstrated the presence of a spinal source of CSF leakage in all 3 patients. There is no evidence for an association between spontaneous intracranial hypotension and CSF leaks at the level of the skull base. Moreover, the authors' study suggests that a spinal source for CSF leakage should even be suspected in patients with orthostatic headaches who have a documented skull base CSF leak.
Factors impacting cerebrospinal fluid leak rates in endoscopic sellar surgery.
Karnezis, Tom T; Baker, Andrew B; Soler, Zachary M; Wise, Sarah K; Rereddy, Shruthi K; Patel, Zara M; Oyesiku, Nelson M; DelGaudio, John M; Hadjipanayis, Constantinos G; Woodworth, Bradford A; Riley, Kristen O; Lee, John; Cusimano, Michael D; Govindaraj, Satish; Psaltis, Alkis; Wormald, Peter John; Santoreneos, Steve; Sindwani, Raj; Trosman, Samuel; Stokken, Janalee K; Woodard, Troy D; Recinos, Pablo F; Vandergrift, W Alexander; Schlosser, Rodney J
2016-11-01
In patients undergoing transnasal endoscopic sellar surgery, an analysis of risk factors and predictors of intraoperative and postoperative cerebrospinal fluid leak (CSF) would provide important prognostic information. A retrospective review of patients undergoing endoscopic sellar surgery for pituitary adenomas or craniopharyngiomas between 2002 and 2014 at 7 international centers was performed. Demographic, comorbidity, and tumor characteristics were evaluated to determine the associations between intraoperative and postoperative CSF leaks. Correlations between reconstructive and CSF diversion techniques were associated with postoperative CSF leak rates. Odds ratios (OR) were identified using a multivariate logistic regression model. Data were collected on 1108 pituitary adenomas and 53 craniopharyngiomas. Overall, 30.1% of patients had an intraoperative leak and 5.9% had a postoperative leak. Preoperative factors associated with increased intraoperative leaks were mild liver disease, craniopharyngioma, and extension into the anterior cranial fossa. In patients with intraoperative CSF leaks, postoperative leaks occurred in 10.3%, with a higher postoperative leak rate in craniopharyngiomas (20.8% vs 5.1% in pituitary adenomas). Once an intraoperative leak occurred, craniopharyngioma (OR = 4.255, p = 0.010) and higher body mass index (BMI) predicted postoperative leak (OR = 1.055, p = 0.010). In patients with an intraoperative leak, the use of septal flaps reduced the occurrence of postoperative leak (OR = 0.431, p = 0.027). Rigid reconstruction and CSF diversion techniques did not impact postoperative leak rates. Intraoperative CSF leaks can occur during endoscopic sellar surgery, especially in larger tumors or craniopharyngiomas. Once an intraoperative leak occurs, risk factors for postoperative leaks include craniopharyngiomas and higher BMI. Use of septal flaps decreases this risk. © 2016 ARS-AAOA, LLC.
Occurrence of occult CSF leaks during standard FESS procedures.
Bucher, S; Kugler, A; Probst, E; Epprecht, L; Stadler, R S; Holzmann, D; Soyka, M B
2018-03-18
To determine the incidence of occult cerebrospinal fluid leaks (CSF) after functional endoscopic sinus surgery (FESS) and to evaluate the diagnostic performance of beta2-transferrin in blood-contaminated conditions. Prospective cohort study. An analysis of 57 intraoperative samples using hydrogel 6 beta2-transferrin assay after FESS was undertaken. In case of CSF positive samples and continuing rhinorrhea, reanalysis after more than 1 year was conducted. In-vivo analysis of a primary spontaneous CSF leak sample took place to verify difficulties in detecting beta2-transferrin in blood-contaminated settings. Own titrations were performed to evaluate detection limits of CSF by beta2-transferrin and beta-trace protein assays in these settings. An incidence of 13% for occult CSF leaks after FESS was found. In blood-contaminated conditions, routine beta2-transferrin assays showed low sensitivity. In over 1 year follow-up, all samples were negative for CSF and none of them developed clinical relevant CSF leaks or meningitis. Occult and clinically irrelevant CSF leaks do occur in a significant proportion of patients during and shortly after FESS. Intra- and postoperatively, routine beta2-transferrin assays show low sensitivity. They should not be used in these settings. The clinical course of patients with occult CSF leaks indicated possibility of an uneventful follow-up.
Thielen, Kent R; Sillery, John C; Morris, Jonathan M; Hoxworth, Joseph M; Diehn, Felix E; Wald, John T; Rosebrock, Richard E; Yu, Lifeng; Luetmer, Patrick H
2015-03-01
Precise localization and understanding of the origin of spontaneous high-flow spinal CSF leaks is required prior to targeted treatment. This study demonstrates the utility of ultrafast dynamic CT myelography for the precise localization of high-flow CSF leaks caused by spiculated spinal osteophytes. This study reports a series of 14 patients with high-flow CSF leaks caused by spiculated spinal osteophytes who underwent ultrafast dynamic CT myelography between March 2009 and December 2010. There were 10 male and 4 female patients, with an average age of 49 years (range 37-74 years). The value of ultrafast dynamic CT myelography in depicting the CSF leak site was qualitatively assessed. In all 14 patients, ultrafast dynamic CT myelography was technically successful at precisely demonstrating the site of the CSF leak, the causative spiculated osteophyte piercing the dura, and the relationship of the implicated osteophyte to adjacent structures. Leak sites included 3 cervical, 11 thoracic, and 0 lumbar levels, with 86% of the leaks occurring from C-5 to T-7. Information obtained from the ultrafast dynamic CT myelogram was considered useful in all treated CSF leaks. Spinal osteophytes piercing the dura are a more frequent cause of high-flow CSF leaks than previously recognized. Ultrafast dynamic CT myelography adds value beyond standard dynamic myelography or digital subtraction myelography in the diagnosis and anatomical characterization of high-flow spinal CSF leaks caused by these osteophytes. This information allows for appropriate planning for percutaneous or surgical treatment.
Reinstein, Eyal; Pariani, Mitchel; Bannykh, Serguei; Rimoin, David L; Schievink, Wouter I
2013-04-01
We aimed to assess the frequency of connective tissue abnormalities among patients with cerebrospinal fluid (CSF) leaks in a prospective study using a large cohort of patients. We enrolled a consecutive group of 50 patients, referred for consultation because of CSF leak. All patients have been carefully examined for the presence of connective tissue abnormalities, and based on findings, patients underwent genetic testing. Ancillary diagnostic studies included echocardiography, eye exam, and histopathological examinations of skin and dura biopsies in selected patients. We identified nine patients with heritable connective tissue disorders, including Marfan syndrome, Ehlers-Danlos syndrome and other unclassified forms. In seven patients, spontaneous CSF leak was the first noted manifestation of the genetic disorder. We conclude that spontaneous CSF leaks are associated with a spectrum of connective tissue abnormalities and may be the first noted clinical presentation of the genetic disorder. We propose that there is a clinical basis for considering spontaneous CSF leak as a clinical manifestation of heritable connective tissue disorders, and we suggest that patients with CSF leaks should be screened for connective tissue and vascular abnormalities.
Elevated body mass index and risk of postoperative CSF leak following transsphenoidal surgery
Dlouhy, Brian J.; Madhavan, Karthik; Clinger, John D.; Reddy, Ambur; Dawson, Jeffrey D.; O’Brien, Erin K.; Chang, Eugene; Graham, Scott M.; Greenlee, Jeremy D. W.
2012-01-01
Object Postoperative CSF leakage can be a serious complication after a transsphenoidal surgical approach. An elevated body mass index (BMI) is a significant risk factor for spontaneous CSF leaks. However, there is no evidence correlating BMI with postoperative CSF leak after transsphenoidal surgery. The authors hypothesized that patients with elevated BMI would have a higher incidence of CSF leakage complications following transsphenoidal surgery. Methods The authors conducted a retrospective review of 121 patients who, between August 2005 and March 2010, underwent endoscopic endonasal transsphenoidal surgeries for resection of primarily sellar masses. Patients requiring extended transsphenoidal approaches were excluded. A multivariate statistical analysis was performed to investigate the association of BMI and other risk factors with postoperative CSF leakage. Results In 92 patients, 96 endonasal endoscopic transsphenoidal surgeries were performed that met inclusion criteria. Thirteen postoperative leaks occurred and required subsequent treatment, including lumbar drainage and/or reoperation. The average BMI of patients with a postoperative CSF leak was significantly greater than that in patients with no postoperative CSF leak (39.2 vs 32.9 kg/m2, p = 0.006). Multivariate analyses indicate that for every 5-kg/m2 increase in BMI, patients undergoing a transsphenoidal approach for a primarily sellar mass have 1.61 times the odds (95% CI 1.10–2.29, p = 0.016, by multivariate logistic regression) of having a postoperative CSF leak. Conclusions Elevated BMI is an independent predictor of postoperative CSF leak after an endonasal endoscopic transsphenoidal approach. The authors recommend that patients with BMI greater than 30 kg/m2 have meticulous sellar reconstruction at surgery and close monitoring postoperatively. PMID:22443502
Tamura, Ryota; Tomio, Ryosuke; Mohammad, Farrag; Toda, Masahiro; Yoshida, Kazunari
2018-03-16
OBJECTIVE The anterior transpetrosal approach (ATPA) was established in 1984 and has been particularly effective for petroclival tumors. Although some complications associated with this approach, such as venous hemorrhage in the temporal lobe and nervous disturbances, have been resolved over the years, the incidence rate of CSF leaks has not greatly improved. In this study, some varieties of air cell tracts that are strongly related to CSF leaks are demonstrated. In addition, other pre- and postoperative risk factors for CSF leakage after ATPA are discussed. METHODS Preoperative and postoperative target imaging of the temporal bone was performed in a total of 117 patients who underwent ATPA, and various surgery-related parameters were analyzed. RESULTS The existence of air cells at the petrous apex, as well as fluid collection in the mastoid antrum detected by a postoperative CT scan, were possible risk factors for CSF leakage. Tracts that directly connected to the antrum from the squamous part of the temporal bone and petrous apex, rather than through numerous air cells, were significantly related to CSF leak and were defined as "direct tract." All patients with a refractory CSF leak possessed "unusual tracts" that connected to the attic, tympanic cavity, or eustachian tube, rather than through the mastoid antrum. CONCLUSIONS Preoperative assessment of petrous pneumatization types is necessary to prevent CSF leaks. Direct and unusual tracts are particularly strong risk factors for CSF leaks.
Borumandi, Farzad
2013-01-01
Compared to the cerebrospinalfluid (CSF) leak through the nose and ear, the orbital CSF leak is a rare and underreported condition following head trauma. We present the case of a 49-year-old woman with oedematous eyelid swelling and ecchymosis after a seemingly trivial fall onto the right orbit. Apart from the above, she was clinically unremarkable. The CT scan revealed a minimally displaced fracture of the orbital roof with no emphysema or intracranial bleeding. The fractured orbital roof in combination with the oedematous eyelid swelling raised the suspicion for orbital CSF leak. The MRI of the neurocranium demonstrated a small-sized CSF fistula extending from the anterior cranial fossa to the right orbit. The patient was treated conservatively and the lid swelling resolved completely after 5 days. Although rare, orbital CSF leak needs to be included in the differential diagnosis of periorbital swelling following orbital trauma. PMID:24323381
Can the Risks of Cerebrospinal Fluid Leak After Vestibular Schwannoma Surgery Be Predicted?
Russel, Adrien; Hoffmann, Charles P; Nguyen, Duc T; Beurton, Renaud; Parietti-Winkler, Cécile
2017-02-01
Identifying predictive factors of cerebrospinal fluid (CSF) leak after translabyrinthine approach (TLA) for vestibular schwannoma. Retrospective study. Tertiary care center. All patients (n = 275) operated for a vestibular schwannoma by TLA between 2004 and 2013 were included. Vestibular schwannoma surgery by TLA. The rate of postoperative CSF leak considering the age, sex, body mass index (BMI), tumor staging, and duration of surgical procedure. A logistic regression model was used to identify the predictors and compute a biometric predictive model of CSF leak. Thirty-three patients (12.0%) developed a CSF leak after surgery. In a multivariable model, an increased risk of CSF leak was found for younger patients (OR 0.95, 95% CI 0.92-0.98), longer duration of surgery (OR 1.85, 95% CI 1.12-3.05), and the male sex (0 = male; 1 = female; OR 0.22, 95% CI 0.09-0.54), while also adjusting for BMI. The probability of developing a CSF leak after vestibular schwannoma surgery was calculated using a statistical prediction model, with a percentage of false negative of 7.0% and an overall correct prediction of 88.4%. The predictors of CSF leak after TLA for vestibular schwannoma are young age, male sex, longer duration of surgery, which adjusting for BMI. In this regard, the surgical team should adapt its management during pre- and postoperative period to decrease the likelihood of a leak.
Rapid spontaneous cerebrospinal fluid leak detected in the gastrointestinal tract.
Ma, Hong Yun; Sen, Papia; Stein, Evan G; Freeman, Leonard M
2014-02-01
There are many causes of cerebrospinal (CSF) leaks. Most cases are secondary to blunt trauma and iatrogenic trauma caused by postoperative sequelae. Occasionally, CSF leakage may occur from nontraumatic or "spontaneous" causes, such as benign intracranial hypertension and "empty sella syndrome." Mass effect due to an encephalocele or meningocele may also be seen. Radionuclide cisternography is a sensitive method of determining CSF leak when combined with intranasal cotton pledget placement and analysis. We present a spontaneous CSF fluid leak that was detected when scintigraphic activity appeared first in the gastrointestinal tract.
Cohen, Salomon; Jones, Samuel H; Dhandapani, Sivashanmugam; Negm, Hazem M; Anand, Vijay K; Schwartz, Theodore H
2018-01-01
Postoperative cerebrospinal fluid (CSF) leak is a persistent, albeit much less prominent, complication following endonasal endoscopic surgery. The pathology with highest risk is suprasellar meningiomas. A postoperative lumbar drain (LD) is used to decrease the risk of CSF leak but is not universally accepted. To compare the rates of postoperative CSF leak between patients with and without LD who underwent endonasal endoscopic surgical resection of suprasellar meningiomas. A consecutive series of newly diagnosed suprasellar meningiomas was drawn from a prospectively acquired database of endonasal endoscopic surgeries at our institution. An intraoperative, preresection LD was placed and left open at 5 cc/h for ∼48 h. In a subset of patients, the LD could not be placed. Rates of postoperative CSF leak were compared between patients with and without an LD. Twenty-five patients underwent endonasal endoscopic surgical resection of suprasellar meningiomas. An LD could not be placed in 2 patients. There were 2 postoperative CSF leaks (8%), both of which occurred in the patients who did not have an LD (P = .0033). The average body mass index (BMI) of the patients in whom the LD could not be placed was 39.1 kg/m2, compared with 27.6 kg/m2 for those in whom the LD could be placed (P = .009). In the subgroup of obese patients (BMI > 30 kg/m2), LD placement was protective against postoperative CSF leak (P = .022). The inability to place an LD in patients with obesity is a risk factor for postoperative CSF leak. An LD may be useful to prevent postoperative CSF leak, particularly in patients with elevated BMI. Copyright © 2017 by the Congress of Neurological Surgeons
Heaton, Chase M; Goldberg, Andrew N; Pletcher, Steven D; Glastonbury, Christine M
2012-07-01
Anatomic variations in skull base anatomy may predispose the surgeon to inadvertent skull base injury with resultant cerebrospinal fluid (CSF) leak during functional endoscopic sinus surgery (ESS). Our objective was to compare preoperative sinus imaging of patients who underwent FESS with and without CSF leak to elucidate these variations. In this retrospective case-control study, 18 patients with CSF leak following FESS for chronic rhinosinusitis (CRS) from 2000 to 2011 were compared to 18 randomly selected patients who underwent preoperative imaging for FESS for CRS. Measurements were obtained from preoperative computed tomography images with specific attention to anatomic differences in cribriform plate and ethmoid roof heights in the coronal plane, and the skull base angle in the sagittal plane. Mean values of measured variables were compared using a nonparametric Mann-Whitney test. When compared to controls, patients with CSF leak demonstrated a greater angle of the skull base in the sagittal plane (P < .001) and a greater slope of the skull base in the coronal plane (P < .006). A lower cribriform height relative to ethmoid roof height was also noted in cases of CSF leak as compared to controls (P < .04). A steep skull base angle in the sagittal plane, a greater slope of the skull base in the coronal plane, and a low cribriform height relative to the ethmoid roof predispose the patient to CSF leak during FESS. Preoperative review of imaging with specific attention paid to these anatomic variations may help to prevent iatrogenic CSF leak. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
Ziu, Mateo; Jimenez, David F
2013-11-01
Presented herein is a review of the history of fat graft use in preventing iatrogenic cerebrospinal fluid (CSF) rhinorrhea after transsphenoidal surgery. Since the first transsphenoidal surgeries were described in the early 1900s, the techniques of sellar packing to prevent CSF leak have evolved. Kanavel, Halstead, and Cushing used bismuth- or iodine-soaked gauze. Under Dandy's influence, fascia lata was the first autologous material to be used for the repair and prevention of CSF rhinorrhea. The use of autologous fat graft for this purpose has only been reported in recent decades. Montgomery was the first to use abdominal fat to obliterate the middle ear cavity in 1964, and Collins reported the first transsphenoidal application of fat graft in 1973. Other reports by Kirchner, Tindall, and Wilson followed. Copyright © 2013. Published by Elsevier Inc.
Community-acquired Serratia marcescens meningitis.
Peeters, A; Vandercam, B; Sindic, C J; Hantson, P; Mahieu, P
1997-11-01
Serratia marcescens is an unusual cause of community-acquired meningitis in adults. We report a case of S. marcescens meningitis occurring 29 years after a head injury and preceded by 3 years of intermittent nasal discharge of cerebrospinal fluid (CSF). One month before admission, the patient had received treatment with cefadroxil. This case illustrates the risk of Gram-negative bacillary meningitis in patients with a CSF leak when they are treated with antibiotics. When patients have a chronic clear nasal discharge, one should look for a past medical history of head injury before prescribing antibiotics. In the presence of a fistula, any antibiotherapy may lead to the selection of resistant organisms which may be difficult to treat. Due to the high risk of meningitis and the fact that spontaneous closure in delayed CSF rhinorrhoea is unlikely, surgical repair of any associated fistulae is mandatory.
Chern, Alexander; Hunter, Jacob B; Bennett, Marc L
2017-01-01
To determine if cranioplasty techniques following translabyrinthine approaches to the cerebellopontine angle are cost-effective. Retrospective case series. One hundred eighty patients with available financial data who underwent translabyrinthine approaches at a single academic referral center between 2005 and 2015. Cranioplasty with a dural substitute, layered fat graft, and a resorbable mesh plate secured with screws Main Outcome Measures: billing data was obtained for each patient's hospital course for translabyrinthine approaches and postoperative cerebrospinal fluid (CSF) leaks. One hundred nineteen patients underwent translabyrinthine approaches with an abdominal fat graft closure, with a median cost of $25759.89 (range, $15885.65-$136433.07). Sixty-one patients underwent translabyrinthine approaches with a dural substitute, abdominal fat graft, and a resorbable mesh for closure, with a median cost of $29314.97 (range, $17674.28-$111404.55). The median cost of a CSF leak was $50401.25 (range, $0-$384761.71). The additional cost of a CSF leak when shared by all patients who underwent translabyrinthine approaches is $6048.15. The addition of a dural substitute and a resorbable mesh plate after translabyrinthine approaches reduced the CSF leak from 12 to 1.9%, an 84.2% reduction, and a median savings per patient of $2932.23. Applying our cohort's billing data to previously published cranioplasty techniques, costs, and leak rate improvements after translabyrinthine approaches, all techniques were found to be cost-effective. Resorbable mesh cranioplasty is cost-effective at reducing CSF leaks after translabyrinthine approaches. Per our billing data and achieving the same CSF leak rate, cranioplasty costs exceeding $5090.53 are not cost-effective.
Sun, Ira; Lim, Jia Xu; Goh, Chun Peng; Low, Shiong Wen; Kirollos, Ramez W; Tan, Chuen Seng; Lwin, Sein; Yeo, Tseng Tsai
2016-09-22
Postoperative cerebrospinal fluid (CSF) leak is a serious complication following trans-sphenoidal surgery for which elevated body mass index (BMI) has been implicated as a risk factor, albeit only in two recent North American studies. Given the paucity of evidence, we sought to determine if this association held true in an Asian population, where BMI criteria for obesity differ from the international standard. A retrospective study of 119 patients who underwent 123 trans-sphenoidal procedures for sellar lesions between May 2000 and May 2012 was conducted. Univariate and multivariate logistic regression analyses were performed to investigate the impact of elevated BMI and other risk factors on postoperative CSF leak. We found 10 (8.1%) procedures in ten patients that were complicated by postoperative CSF leak. The median BMI of patients with postoperative leak following trans-sphenoidal procedures was significantly higher than that of patients without postoperative CSF leak (27.0 kg/m2 vs. 24.6 kg/m2; p = 0.018). Patients categorised as either moderate or high risk under the Asian BMI classification were more likely to suffer from a postoperative leak (p = 0.030). Repeat procedures were also found to be significantly associated with postoperative CSF leak (p = 0.041). Elevated BMI predicts for postoperative CSF leak following trans-sphenoidal procedures, even in an Asian population, where the definition of obesity differs from international standards. Thus, BMI should be borne in mind during local and regional management decision-making processes prior to such procedures.
Heavily T2-weighted MR myelography vs CT myelography in spontaneous intracranial hypotension.
Wang, Y-F; Lirng, J-F; Fuh, J-L; Hseu, S-S; Wang, S-J
2009-12-01
To assess the diagnostic accuracy of heavily T2-weighted magnetic resonance myelography (MRM) in patients with spontaneous intracranial hypotension (SIH). Patients with SIH were recruited prospectively, and first underwent MRM and then computed tomographic myelography (CTM). The results of MRM were validated with the gold standard, CTM, focusing on 1) CSF leaks along the nerve roots, 2) epidural CSF collections, and 3) high-cervical (C1-3) retrospinal CSF collections. Comparisons of these 3 findings between the 2 studies were made by kappa statistics and agreement rates. Targeted epidural blood patches (EBPs) were placed at the levels of CSF leaks if supportive treatment failed. Nineteen patients (6 men and 13 women, mean age 37.9 +/- 8.6 years) with SIH completed the study. MRM did not differ from CTM in the detection rates of CSF leaks along the nerve roots (84% vs 74%, p = 0.23), high-cervical retrospinal CSF collections (32% vs 16%, p = 0.13), and epidural CSF collections (89% vs 79%, p = 0.20). MRM demonstrated more spinal levels of CSF leaks (2.2 +/- 1.7 vs 1.5 +/- 1.5, p = 0.011) and epidural collections (12.2 +/- 5.9 vs 7.1 +/- 5.8, p < 0.001) than CTM. The overall level-by-level concordance was substantial for CSF leaks along the nerve roots (C1-L3) (kappa = 0.71, p < 0.001, agreement = 95%) and high-cervical retrospinal CSF collections (C1-3) (kappa = 0.73, p < 0.001, agreement = 92%), and moderate for epidural CSF collections (C1-L3) (kappa = 0.47, p < 0.001, agreement = 72%). Ten of the 14 patients (71%) receiving targeted EBPs experienced sustained symptomatic relief after a single attempt. Heavily T2-weighted magnetic resonance myelography was accurate in localizing CSF leaks for patients with spontaneous intracranial hypotension. This noninvasive technique may be an alternative to computed tomographic myelography before targeted epidural blood patches.
Filippidis, Aristotelis S; Kalani, M Yashar S; Nakaji, Peter; Rekate, Harold L
2011-11-01
Negative-pressure and low-pressure hydrocephalus are rare clinical entities that are frequently misdiagnosed. They are characterized by recurrent episodes of shunt failure because the intracranial pressure is lower than the opening pressure of the valve. In this report the authors discuss iatrogenic CSF leaks as a cause of low- or negative-pressure hydrocephalus after approaches to the cranial base. The authors retrospectively reviewed cases of low-pressure or negative-pressure hydrocephalus presenting after cranial approaches complicated with a CSF leak at their institution. Three patients were identified. Symptoms of high intracranial pressure and ventriculomegaly were present, although the measured pressures were low or negative. A blocked communication between the ventricles and the subarachnoid space was documented in 2 of the cases and presumed in the third. Shunt revisions failed repeatedly. In all cases, temporary clinical and radiographic improvement resulted from external ventricular drainage at subatmospheric pressures. The CSF leaks were sealed and CSF communication was reestablished operatively. In 1 case, neck wrapping was used with temporary success. Negative-pressure or low-pressure hydrocephalus associated with CSF leaks, especially after cranial base approaches, is difficult to treat. The solution often requires the utilization of subatmospheric external ventricular drains to establish a lower ventricular drainage pressure than the drainage pressure created in the subarachnoid space, where the pressure is artificially lowered by the CSF leak. Treatment involves correction of the CSF leak, neck wrapping to increase brain turgor and allow the pressure in the ventricles to rise to the level of the opening pressure of the valve, and reestablishing the CSF route.
Lumbar subarachnoid drainage in cerebrospinal fluid leaks after lateral skull base surgery.
Allen, Kyle P; Isaacson, Brandon; Purcell, Patricia; Kutz, Joe Walter; Roland, Peter S
2011-12-01
To determine the efficacy of lumbar drainage in managing cerebrospinal fluid (CSF) leak after lateral skull base surgery. Retrospective case review. Academic tertiary referral center. Patients who had a lumbar subarachnoid drain placed after a lateral skull base procedure between July 1999 and February 2010 were included. Patients were identified by searching medical records for lateral skull base approach Current Procedural Terminology codes. The following variables were recorded for each subject: diagnosis, type of lateral skull base operation, duration of lumbar drainage, need for revision surgery, and presence of meningitis. Successful cessation of postoperative CSF leakage. Five hundred eight charts were reviewed, and 63 patients were identified who received a lumbar drain after a lateral skull base operation. The most common diagnosis was acoustic neuroma in 61.9%. The most common skull base approaches were the translabyrinthine, middle fossa, and transpetrosal approaches. Approximately 60.3% of patients had CSF rhinorrhea, 23.8% had an incisional leak, and 14.3% had otorrhea. The mean duration of lumbar drainage was 4.6 days. Forty eight (76.2%) study subjects had resolution of their CSF leak with lumbar drainage. Fifteen patients (23.8%) required revision surgery to stop the CSF leak. Lumbar drainage was successful in 90% of leaks after the translabyrinthine approach but in only 50% of those undergoing a suboccipital approach, which was a statistically significant difference. Postoperative CSF leaks after lateral skull base surgery can be managed with a lumbar subarachnoid drain in a majority of cases but is more successful after the translabyrinthine than the suboccipital approach. Recurrent CSF leaks after lumbar drainage is likely to require a revision operation.
Shields, Lisa B E; Johnson, John R; Shields, Christopher B
2016-11-01
Posterior reversible encephalopathy syndrome (PRES) is a clinicoradiological syndrome characterized by headaches, altered mental status, seizures, and visual disturbances. Classic MRI findings include white matter changes of the parieto-occipital regions. This syndrome has been encountered in myriad medical illnesses, including hypertension, preeclampsia/eclampsia, and immunosuppressive conditions. While the pathogenesis of the disorder is unclear, vasoconstriction and hypoperfusion leading to brain ischemia and vasogenic edema have been implicated as potential mechanisms. The authors present, to the best of their knowledge, the first case of PRES following a thoracic spinal surgery-induced dural leak noted on resection of the fifth rib during a thoracotomy for a T4-5 discectomy. Brain MRI revealed large areas of increased FLAIR and T2 hyperintensity in the superior posterior frontal lobes, superior and medial parietal lobes, and bilateral occipital lobes. Following repair of the CSF leak, the patient's symptoms resolved. Spinal surgeons should be alert to the potentially life-threatening condition of PRES, especially in a hypertensive patient who experiences surgery-induced dural leakage. The development of a severe positional headache with neurological signs is a red flag that suggests the presence of PRES. Prompt attention to the diagnosis and treatment of this condition by repairing the dural leak via surgery or expeditious blood patch increases the likelihood of a favorable outcome.
Eseonu, Chikezie I; Goodwin, C Rory; Zhou, Xin; Theodros, Debebe; Bender, Matthew T; Mathios, Dimitrios; Bettegowda, Chetan; Lim, Michael
2015-12-01
Calcium phosphate cement provides a biomaterial that can be used for calvarial reconstruction in a retrosigmoid craniectomy for microvascular decompression (MVD). This study evaluates the outcomes of postoperative CSF leak and wound infection for patients undergoing a complete cranioplasty using calcium phosphate cement versus incomplete cranioplasty using polyethylene titanium mesh following a retrosigmoid craniectomy for MVD. The authors evaluated 211 cases involving patients who underwent first-time retrosigmoid craniectomies performed by a single attending surgeon fortrigeminal neuralgia from October 2008 to June 2014. From this patient population, 111 patients underwent calvarial reconstruction after retrosigmoid craniectomy using polyethylene titanium mesh, and 100 patients had reconstructions using calcium phosphate cement. A Pearson's chi-square test was used to compare postoperative complications of CSF leak and wound infection in these 2 types of cranioplasties. The polyethylene titanium mesh group included 5 patients (4.5%) with postoperative CSF leak or pseudomeningocele and 3 patients (2.7%) with wound infections. In the calcium phosphate cement group, no patients had a CSF leak, and 2 patients (2%) had wound infections. This represented a statistically significant reduction of postoperative CSF leak in patients who underwent calcium phosphate reconstructions of their calvarial defect compared with those who underwent polyethylene titanium mesh reconstructions (p = 0.03). No significant difference was seen between the 2 groups in the number of patients with postoperative wound infections. Calcium phosphate cement provides a viable alternative biomaterial for calvarial reconstruction of retrosigmoid craniectomy defects in patients who have an MVD. The application of this material provides a biocompatible barrier that reduces the incidence of postoperative CSF leaks.
Spinal cerebrospinal fluid leak as the cause of chronic subdural hematomas in nongeriatric patients.
Beck, Jürgen; Gralla, Jan; Fung, Christian; Ulrich, Christian T; Schucht, Philippe; Fichtner, Jens; Andereggen, Lukas; Gosau, Martin; Hattingen, Elke; Gutbrod, Klemens; Z'Graggen, Werner J; Reinert, Michael; Hüsler, Jürg; Ozdoba, Christoph; Raabe, Andreas
2014-12-01
The etiology of chronic subdural hematoma (CSDH) in nongeriatric patients (≤ 60 years old) often remains unclear. The primary objective of this study was to identify spinal CSF leaks in young patients, after formulating the hypothesis that spinal CSF leaks are causally related to CSDH. All consecutive patients 60 years of age or younger who underwent operations for CSDH between September 2009 and April 2011 at Bern University Hospital were included in this prospective cohort study. The patient workup included an extended search for a spinal CSF leak using a systematic algorithm: MRI of the spinal axis with or without intrathecal contrast application, myelography/fluoroscopy, and postmyelography CT. Spinal pathologies were classified according to direct proof of CSF outflow from the intrathecal to the extrathecal space, presence of extrathecal fluid accumulation, presence of spinal meningeal cysts, or no pathological findings. The primary outcome was proof of a CSF leak. Twenty-seven patients, with a mean age of 49.6 ± 9.2 years, underwent operations for CSDH. Hematomas were unilateral in 20 patients and bilateral in 7 patients. In 7 (25.9%) of 27 patients, spinal CSF leakage was proven, in 9 patients (33.3%) spinal meningeal cysts in the cervicothoracic region were found, and 3 patients (11.1%) had spinal cysts in the sacral region. The remaining 8 patients (29.6%) showed no pathological findings. The direct proof of spinal CSF leakage in 25.9% of patients suggests that spinal CSF leaks may be a frequent cause of nongeriatric CSDH.
Novel laser tissue-soldering technique for dural reconstruction.
Gil, Ziv; Shaham, Amit; Vasilyev, Tamar; Brosh, Tamar; Forer, Boaz; Katzir, Abraham; Fliss, Dan M
2005-07-01
The goal of this study was to use a modified version of the CO2 laser-soldering system to develop a simple and reliable technique for the repair of dural defects after excision of brain tumors. The authors used a CO2 fiber optic laser system that they had developed for heating, monitoring, and controlling tissue temperature in situ and in real time, thereby reducing damage to the brain parenchyma. They adapted the system for dural closure by using free fascial grafts in a porcine model. Measures for estimation of reconstruction quality included visual assessment under magnification and direct measurements of adhesive strength and cerebrospinal fluid leak (CSF) pressure. Reliable soldering was achieved in 54 of 57 experiments, providing a 95% success rate. The average peak adhesive strength was 82 +/- 3 mN/cm2. The measured leak pressure of the fascia-dura mater bond was 66 +/- 5 mm Hg. Conventional suturing performed using Prolene stitches resulted in immediate CSF leakage from areas between the stitches and from the area of the needle hole itself. Fascia-dura mater soldering using the CO2 laser is feasible and may support CSF pressure up to six times higher than normal intracranial pressure. Findings of this study may provide a basis for the development of new tools for dural reconstruction.
An Automated, Gravity-driven CSF Drainage System Decreases Complications and Lowers Costs
Lieberson, Robert E; Meyer, William; Trang, Tung
2017-01-01
Background: FlowSafeTM (BeckerSmith Medical, Irvine, CA, USA) is a novel, robotic, external lumbar drainage (ELD) system, which was designed to control cerebrospinal fluid (CSF) drainage, reduce complications, and decrease treatment costs. Methods: Forty-seven consecutive neurosurgical patients requiring ELD were treated using the FlowSafe system. Results: In 39 of 40 patients with traumatic and surgical dural openings, potential CSF leaks were avoided. In seven patients with suspected normal pressure hydrocephalus, post-infectious ventriculomegaly, or pseudotumor cerebrum, we were able to assess the likelihood of improvement with shunting. The system, therefore, produced what we considered to be the “desired result” in 46 of 47 patients (98%). Our one treatment failure (2%) involved a patient with unrecognized hydrocephalus who, following a Chiari repair with a dural patch graft, was drained for six days. A persistent CSF leak eventually required a reoperation. Two patients (4%) described low-pressure headaches during treatment. Both responded to temporarily suspending or reducing the drainage rate. We saw no complications. Required nursing interventions were minimal. Conclusions: The FlowSafe system was safe and effective. In our experience, there were fewer complications compared to currently available ELD systems. The FlowSafe was well tolerated by our patients. The near elimination of nursing interventions should allow lumbar drainage to be delivered in less costly, non-intensive care unit settings. Larger trials will be needed. PMID:28331772
Cassano, Michele; Felippu, Alexandre
2009-12-01
Endoscopic transnasal approaches to the skull base have revolutionized the treatment of cerebrospinal fluid (CSF) fistulae, making repair less invasive and more effective compared with craniotomy or extracranial techniques. This study evaluated, retrospectively, the results of endoscopic repair of dural defects with the use of mucoperiostal grafts taken from the lower turbinate. Between January 1997 and January 2007, 125 cases of anterior skull base CSF fistulae were treated endoscopically at the Instituto Felippu de Otorrinolaringologia, Sao Paolo, Brazil, and at the Department of Otolaryngology of the University Hospital "Ospedali Riuniti", Foggia, Italy. Fistula closure was achieved by overlay apposition of a lower turbinate mucoperiostal graft fixated with fibrin glue and Surgicell. The etiology of the fistula was accidental trauma in 41 cases, iatrogenic trauma in 29, skull base tumour in 12, and spontaneous in 43. The site of the defect was the sphenoid sinus in 43 patients, the cribriform plate in 42, the anterior ethmoid roof in 21, the posterior ethmoid roof in 17, and the posterior wall of the frontal sinus in 2. The success rate at first attempt was 94.4%; the 7 cases of postoperative recurrent CSF leakage involved patients presenting with spontaneous fistula and elevated intracranial pressure; 5 of these had a body-mass index > 30 and 3 suffered from diabetes mellitus. In our hands, the success rate of endoscopic fistula repair was high, even in defects larger than 2 cm. Success rates may be further improved with accurate diagnosis of elevated intracranial pressure, a contributing factor to failure of spontaneous fistula repair.
Zappella, N; Barrelet, A; Pangon, B; Laurent, V; Bruneel, F
2013-11-01
We reported a case of group A streptococcal meningitis in a patient with a CSF fluid leak. This case underlined several relevant points: (i) an unfrequent cause of bacterial meningitis; (ii) the main diagnosis to evoke when the direct examination of CSF shows Gram+ cocci with a negative pneumococcal antigen; (iii) that bacteria other than Streptococcus pneumoniae are possible in front of a meningitis associated with a CSF fluif leak. Copyright © 2013 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.
Schievink, Wouter I; Palestrant, David; Maya, M Marcel; Rappard, George
2009-03-01
Spontaneous spinal CSF leaks are best known as a cause of orthostatic headache, but may also be the cause of coma. The authors encountered a unique case of a spontaneous spinal CSF leak causing coma 2 days after craniotomy for clipping of an unruptured aneurysm. This 44-year-old woman with autosomal dominant polycystic kidney disease underwent an uneventful craniotomy for an incidental anterior choroidal artery aneurysm. No intraoperative spinal CSF drainage was used. Two days after surgery the patient became comatose with a left oculomotor nerve palsy. Computed tomography scanning revealed a right extraceberal hematoma and loss of gray-white matter differentiation. The hematoma was evacuated and a diagnosis of hemodialysis disequilibrium syndrome was made. Continuous hemodialysis and hyperosmolar therapy were instituted without any improvement. The CT scans were then reinterpreted as showing sagging of the brain, and the patient was placed in the Trendelenburg position which resulted in prompt improvement in her level of consciousness. A CT myelogram demonstrated an upper thoracic CSF leak that eventually required surgical correction. The patient made a complete neurological recovery. Neurological deterioration after craniotomy may be caused by brain sagging caused by a spontaneous spinal CSF leak, similar to intracranial hypotension due to intraoperative lumbar CSF drainage.
A comparison between "sandwich" and conventional methods of repairing spinal dura rupture.
Wang, Hui-ren; Cao, Sheng-sheng; Jiang, Yun-qi; Li, Jun-ning; Li, Xi-lei; Fu, Yun-gen; Zhao, Ming-dong; Dong, Jian
2012-11-01
To study the therapeutic efficacy of the "sandwich" method (medical glue + gelatin sponge + medical glue) of spinal dural repair for preventing cerebrospinal fluid (CSF) leaks during treatment of subdural tumors. Fifty-four patients with spinal subdural tumors treated between April 2007 and June 2011 were retrospectively investigated. The patients were divided into two groups: a conventional group (group A) and a "sandwich" group (group B). The group A patients included 16 males and 7 females with an average tumor course of 11 months (range, 2-34 months). Four of their 23 tumors were in the cervical spine, eight thoracic, and eleven lumbar. The group B patients included 19 males and 12 females with an average tumor course of 12 months (range, 3-36 months). Five of their 31 tumors were in the cervical spines, 10 thoracic, and 16 lumbar. In group A, the dural repairs were performed with interlocking sutures and a gelatin sponge covering the dura; whereas in group B, they were performed with interlocking sutures, painting of medical glue around the dural incision, covering this with a gelatin sponge, and finally covering of the gelatin sponge with medical glue. The total volume of drainage after operation, incidence of CSF leaks, healing of the incision, and recovery of clinical performance were recorded. Compared to group A patients, group B patients had a significantly smaller total volume of drainage (P < 0.05) on the day of surgery, and the first, second, and third postoperative days. The incidence of CSF leakage in group B was also significantly less than in group A (P < 0.05). Before discharge, three patients in group A developd hydrops, which was successfully treated by aspiration, continuous pressure from sandbags, and the prone position. During the first 3 months of follow-up, five patients developed deep hydrops under their incisions but required no treatment. There were no obvious abnormalities in group B. After removal of subdural spinal tumors by incising the dura mater, or in related spinal surgery, application of the "sandwich" complex to the damaged spinal dura reduces the volume of drainage postoperatively and reduces the incidence of CSF leakage. © 2012 Tianjin Hospital and Wiley Publishing Asia Pty Ltd.
Complications of pediatric auditory brain stem implantation via retrosigmoid approach.
Bayazit, Yildirim A; Abaday, Ayça; Dogulu, Fikret; Göksu, Nebil
2011-01-01
We aimed to present the complications of auditory brain stem implantations (ABI) in pediatric patients which were performed via retrosigmoid approach. Between March 2007 and February 2010, five prelingually deaf children underwent ABI (Medel device) operation via retrosigmoid approach. All children had severe cochlear malformations. The ages ranged from 20 months to 5 years. The perioperative complications encountered in 2 patients were evaluated retrospectively. No intraoperative complication was observed in the patients. Cerebrospinal fluid (CSF) leakage was the most common postoperative complication that was seen in 2 patients. The CSF leak triggered a cascade of comorbidities, and elongated the hospitalization. Pediatric ABI surgery can lead to morbidity. The CSF leak is the most common complication encountered in retrosigmoid approach. The other complications usually result from long-term hospital stay during treatment period of the CSF leak. Therefore, every attempt must be made to prevent occurrence of CSF leaks in pediatric ABI operations. Copyright © 2011 S. Karger AG, Basel.
Wan, Yingfeng; Xie, Jixi; Xie, Dajiang; Xue, Zhaoliang; Wang, Yirong; Yang, Shuxu
2016-12-01
The etiology of chronic subdural hematoma (CSDH) in patients is diverse. The primary objective of this article was to discuss one of the causes, spontaneous intracranial hypotension with spinal cerebrospinal fluid (CSF) leak, which is usually neglected by the neurosurgeon. All the consecutive 15 patients who underwent operation for CSDHs between June 2012 and June 2014 at Sir Run Run Shaw Hospital of Zhejiang University were included in this retrospective cohort study. The clinical and imaging data of these patients with CSDHs due to spinal CSF leak were retrospectively studied. Fifteen patients, with a mean age of 53.8 ± 8.3 years, underwent operations for CSDH. Hematomas were unilateral in 4 patients and bilateral in 11 patients. Among these patients, eight patients had recurrence of hematomas after operation due to neglect of spinal CSF leak. All patients had fully recovery. Spinal CSF leak is a cause of cSDH, which is overlooked by the doctor.
Hydroxyapatite cement cranioplasty in translabyrinthine acoustic neuroma surgery.
Arriaga, Moisês A; Chen, Douglas A
2002-05-01
Hydroxyapatite cement cranioplasty (HAC) after translabyrinthine resection of acoustic neuroma is a promising new technique for wound reconstruction. This study reviews the efficacy of HAC for the prevention of cerebrospinal fluid (CSF) leakage and the long-term wound outcomes of HAC versus abdominal fat graft (AFG) reconstruction. This retrospective study of l08 consecutive acoustic neuromas operated on by Pittsburgh Ear Associates uses chart review, telephone interview, and mail questionnaire data. Fifty-four patients received AFG dural repair, and 54 patients received HAC. Seven AFG patients (12.5%) had CSF leaks versus 2 (3.7%) of the overall group of 54 HAC patients. However, none (0%) of the 47 HAC patients had CSF leakage with current HAC techniques. HAC also produced significantly less postauricular wound depression and superior cosmetic results in comparison with AFG. Although HAC patients experienced less postoperative discomfort, wound complications requiring medical or surgical intervention were extremely uncommon in both groups. HAC offers significant CSF leakage control and long-term cosmetic and comfort advantages over AFG alone. We recommend HAC as the standard closure technique for translabyrinthine acoustic neuroma surgery.
Effect of primary empty sella syndrome on pituitary surgery for Cushing's disease.
Mehta, Gautam U; Bakhtian, Kamran D; Oldfield, Edward H
2014-09-01
Primary empty sella syndrome (ESS) results from herniation of arachnoid mater into the pituitary fossa. It has been suggested to have a negative effect on pituitary surgery; however, outcomes in this cohort have not been defined. This study was performed to determine the effect of ESS on immediate and long-term biochemical outcome after pituitary surgery for Cushing's disease (CD). Using a matched cohort study design, the authors followed patients treated with pituitary surgery for CD with and without ESS. Complete ESS was defined as pituitary gland height ≤ 2 mm, whereas partial ESS was defined as pituitary gland height > 2 mm but less than three-quarters of the total sellar depth. The primary end points were immediate and long-term biochemical outcome. Cerebrospinal fluid leaks were recorded as a secondary end point. Seventy-eight patients with CD and primary ESS were identified and matched with 78 patients with CD without ESS. After surgical management, immediate biochemical remission was achieved in 69 patients (88%) with ESS and 75 controls (96%, p = 0.10). Long-term remission was achieved in most patients in both groups (5-year cure: 85% vs 92%, p = 0.10). Among patients with ESS, the presence of complete ESS predicted a worse long-term outcome (p = 0.04). Intraoperative CSF leaks were significantly more frequent with ESS (54% vs 24%, p < 0.001), and despite sellar floor repair, the rate of postoperative CSF leaks was also increased (6% vs 3%, p = 0.27). Biochemical outcome after pituitary surgery for CD was worse in patients with complete ESS, and the risk of a CSF leak was increased with both partial and complete ESS. However, as outcome remains superior to those following alternative therapies and the biology of these tumors is unchanged in the setting of ESS, pituitary surgery should remain the initial treatment of choice.
Borg, Anouk; Kirkman, Matthew A; Choi, David
2016-11-01
Endoscopic skull base surgery is becoming more popular as an approach to the anterior skull base for tumors and cerebrospinal fluid (CSF) fistulae. It offers the advantages of better cosmesis and improved quality of life after surgery. We reviewed the complication rates reported in the literature. A literature search was performed in the electronic database Ovid MEDLINE (1950 to August 25, 2015) with the search item "([Anterior] AND Skull base surgery) AND endoscopic." We identified 82 relevant studies that included 7460 cases. An average overall complication rate of 17.1% (range 0%-68.0%) and a mortality rate of 0.4% (0%-10.0%) were demonstrated in a total of 82 studies that included 7460 cases. The average CSF leak rate for all studies was 8.9% (0%-40.0%) with meningiomas and clival lesions having the greatest CSF leak rates. The most frequent benign pathology encountered was pituitary adenomas (n = 3720, 49.8% of all cases) and the most frequent malignant tumor was esthesioneuroblastoma (n = 120, 1.6% of all cases). Studies that included only CSF fistula repairs had a lower average total complication rate (12.9%) but a greater rate of meningitis compared with studies that reported mixed pathology (2.4% vs. 1.3%). A trend towards a lower total complication rate with increasing study size was observed. The endoscopic approach is an increasingly accepted technique for anterior skull base tumor surgery and is associated with acceptable complication rates. Increasing experience with this technique can decrease rates of complications. Copyright © 2016 Elsevier Inc. All rights reserved.
Petrous bone fractures violating otic capsule.
Magliulo, Giuseppe; Ciniglio Appiani, Mario; Iannella, Giannicola; Artico, Marco
2012-12-01
This study presents our experience with a series of patients suffering from petrous bone fractures violating the otic capsule who underwent subtotal petrosectomy combined with eustachian tube, middle ear, and mastoid obliteration, with the goal of preventing cerebrospinal fluid (CSF) leak and meningitis. This study enrolled 26 patients between 1997 and 2011. The clinical symptoms, otoscopy, and preoperative and postoperative audiometry and facial function, as well as CSF leak or meningitis, were evaluated in each patient. The entire group underwent a subtotal petrosectomy using the technique described in detail by Fisch. In addition, each patient was interviewed using a questionnaire to evaluate the impact on quality of life. Intraoperatively, we found significant CSF leaks in 14 patients (42.5%). No patient reported other episodes of CSF leak or meningitis after the surgery. The patients' responses of facial nerve function were slightly worse than the House-Brackmann evaluation (50% versus 42.3%; p < 0.05). The vast majority (88.5%) of the patients experienced no social impact. Our findings suggest the importance of not underestimating the risk for CSF leak in the petrous bone fractures violating the otic capsule. Preoperative counseling regarding the various troublesome complications must adequately motivate candidates to undergo surgery by pointing out the positive impact of the proposed treatment.
Scarless abdominal fat graft harvest for neurosurgical procedures: technical note.
Trinh, Victoria T; Duckworth, Edward A M
2015-02-01
Background Abdominal fat grafts are often harvested for use in skull base reconstruction and cerebrospinal fluid (CSF) leak repairs, and for operations traversing the nasal sinuses or mastoid bone. Although the endoscopic transnasal surgery has gained significant popularity, in part because it is considered "scarless," a common adjunct, the abdominal fat graft, can result in a disfiguring scar across the abdomen. Objective This is the first report of a scarless abdominal fat graft technique for skull base reconstruction. Methods Ten patients with a median age of 56.5 years (range: 45-73 years) underwent endoscopic transsphenoidal tumor resection with intraumbilical fat graft harvest. Careful circumferential fat dissection at the umbilicus, with progressive retraction of the graft, was crucial to ensure maximal visualization and to prevent injury to the subcutaneous vessels and rectus fascia. Results Following reconstruction of the sellar skull base, all patients did well postoperatively with no evidence of CSF leak. At 12-week follow-up for all patients, there was no evidence of scar, intracavity hematoma, or wound infection. Conclusions Fat graft harvest through an intraumbilical incision results in a scar-free abdominal harvest, and is a useful procedural adjunct to complement "scarless" brain surgery.
Innovative real CSF leak simulation model for rhinology training: human cadaveric design.
AlQahtani, Abdulaziz A; Albathi, Abeer A; Alhammad, Othman M; Alrabie, Abdulkarim S
2018-04-01
To study the feasibility of designing a human cadaveric simulation model of real CSF leak for rhinology training. The laboratory investigation took place at the surgical academic center of Prince Sultan Military Medical City between 2016 and 2017. Five heads of human cadaveric specimens were cannulated into the intradural space through two frontal bone holes. Fluorescein-dyed fluid was injected intracranialy, then endoscopic endonasal iatrogenic skull base defect was created with observation of fluid leak, followed by skull base reconstruction. The outcome measures included subjective assessment of integrity of the design, the ability of creating real CSF leak in multiple site of skull base and the possibility of watertight closure by various surgical techniques. The fluid filled the intradural space in all specimens without spontaneous leak from skull base or extra sinus areas. Successfully, we demonstrated fluid leak from all areas after iatrogenic defect in the cribriform plate, fovea ethmoidalis, planum sphenoidale sellar and clival regions. Watertight closure was achieved in all defects using different reconstruction techniques (overly, underlay and gasket seal closure). The design is simulating the real patient with CSF leak. It has potential in the learning process of acquiring and maintaining the surgical skills of skull base reconstruction before direct involvement of the patient. This model needs further evaluation and competence measurement as training tools in rhinology training.
Cappabianca, Paolo; Esposito, Felice; Magro, Francesco; Cavallo, Luigi Maria; Solari, Domenico; Stella, Lucio; de Divitiis, Oreste
2010-05-01
The objective of this study is to report our experience and illustrate our technique in the use of fibrin glue in the treatment of post-operatory cerebrospinal fluid (CSF) leaks and collections following different neurosurgical procedures. In a 3-year period, 40 subjects underwent endoscopic endonasal approach for different sellar and skull base lesions (three tuberculum sellae meningiomas, six craniopharyngiomas, three Rathke's cleft cysts and 28 pituitary macroadenomas), in which an intraoperative CSF leakage was evident. In such subjects, the fibrin glue was used as a first step of the final phase of the procedure-i.e. the reconstruction of the skull base defect-followed by the other materials employed. Furthermore, ten other patients, who had undergone transsphenoidal (four cases), spinal (two cases), posterior fossa (three cases) and transcortical intraventricular tumour removal (one case) neurosurgical procedures and developed CSF leaks or collections, were conservatively treated by single or repeated in situ injections of "modified" fibrin glue under local anaesthesia according to different described techniques. In total, 50 patients constitute the clinical material of the present study. In the cases where the fibrin glue was used during the reconstruction phase of the procedure (40 cases), the glue was injected inside the tumour cavity to fill the dead space left by the removal of the lesion. In case of post-operative CSF leak or CSF fluid collection (ten cases), after discarding 50-80% of the thrombin solution to obtain prevalence of the product's adhesive properties, fibrin glue was injected directly in the path of the CSF leak or into the collection cavity after aspiration of the collection's content. This was performed with the provided application system or through lumbar or Tuohy needles. Applications were repeated every 48 h until the disappearance of the leak. In all the treated cases, the disappearance of CSF leaks or collections was obtained with a number of applications ranging from one to five. Successful results are stable with a follow-up ranging from 6 months to 3 years. In our experience, the injection of fibrin glue has proved to be effective in filling or sealing post-operative "dead spaces" and treating minor or initial CSF leaks resulting from procedures of transsphenoidal, cranial and spinal surgery, adding another possibility in the management of many of these dreadful complications.
Bonow, Robert H; Bales, James W; Morton, Ryan P; Levitt, Michael R; Zhang, Fangyi
2016-03-01
Intracranial hypotension is a rare condition caused by spontaneous or iatrogenic CSF leaks that alter normal CSF dynamics. Symptoms range from mild headaches to transtentorial herniation, coma, and death. Duret hemorrhages have been reported to occur in some patients with this condition and are traditionally believed to be associated with a poor neurological outcome. A 73-year-old man with a remote history of spinal fusion presented with syncope and was found to have small subdural hematomas on head CT studies. He was managed nonoperatively and discharged with a Glasgow Coma Scale score of 15, only to return 3 days later with obtundation, fixed downward gaze, anisocoria, and absent cranial nerve reflexes. A CT scan showed Duret hemorrhages and subtle enlargement of the subdural hematomas, though the hematomas remained too small to account for his poor clinical condition. Magnetic resonance imaging of the spine revealed a large lumbar pseudomeningocele in the area of prior fusion. His condition dramatically improved when he was placed in the Trendelenburg position and underwent repair of the pseudomeningocele. He was kept flat for 7 days and was ultimately discharged in good condition. On long-term follow-up, his only identifiable deficit was diplopia due to an internuclear ophthalmoplegia. Intracranial hypotension is a rare condition that can cause profound morbidity, including tonsillar herniation and brainstem hemorrhage. With proper identification and treatment of the CSF leak, patients can make functional recoveries.
Felbaum, Daniel R; Mueller, Kyle; Anaizi, Amjad; Mason, Robert B; Jean, Walter C; Voyadzis, Jean M
2016-12-28
Suboccipital craniotomy is a workhorse neurosurgical operation for approaching the posterior fossa but carries a high risk of pseudomeningocele and cerebrospinal fluid (CSF) leak. We describe our experience with a simple T-shaped fascial opening that preserves the occipital myofascial cuff as compared to traditional methods to reduce this risk. A single institution, retrospective review of prospectively collected database was performed of patients that underwent a suboccipital craniectomy or craniotomy. Patient data was reviewed for craniotomy or craniectomy, dural graft, and/or sealant use as well as CSF complications. A pseudomeningocele was defined as a subcutaneous collection of cerebrospinal fluid palpable clinically and confirmed on imaging. A CSF leak was defined as a CSF-cutaneous fistula manifested by CSF leaking through the wound. All patients underwent regular postoperative visits of two weeks, one month, and three months. Our retrospective review identified 33 patients matching the inclusion criteria. Overall, our cohort had a 21% (7/33) rate of clinical and radiographic pseudomeningocele formation with 9% (3/33) requiring surgical revision or a separate procedure. The rate of clinical and radiographic pseudomeningocele formation in the myofascial cuff preservation technique was less than standard techniques (12% and 31%, respectively). Revision or further surgical procedures were also reduced in the myofascial cuff preservation technique vs. the standard technique (6% vs 13%). Preservation of the myofascial cuff during posterior fossa surgery is a simple and adoptable technique that reduces the rate of pseudomeningocele formation and CSF leak as compared with standard techniques.
Panuganti, Bharat A; Leach, Matthew; Antisdel, Jastin
2015-01-01
Cerebrospinal fluid (CSF) rhinorrhea and encephaloceles are rare complications of craniofacial advancement procedures performed in patients with craniofacial dysostoses (CD) to address the ramifications of their midface hypoplasia including obstructed nasal airway, exorbitism, and impaired mastication. Surgical repair of this CSF rhinorrhea is complicated by occult elevations in intracranial pressure (ICP), potentially necessitating open, transcranial repair. We report the first case in otolaryngology literature of a patient with Crouzon syndrome with late CSF rhinorrhea and encephalocele formation after previous LeFort III facial advancement surgery. Describe the case of a patient with Crouzon syndrome who presented with CSF rhinorrhea and encephaloceles as complications of Le Fort III facial advancement surgery. Review the literature pertaining to the incidence and management of post-operative CSF rhinorrhea and encephaloceles. Analyze issues related to repair of these complications, including occult elevations in ICP, the utility of perioperative CSF shunts, and the importance of considering alternative repair schemes to the traditional endonasal, endoscopic approach. Review of the literature describing CSF rhinorrhea and encephalocele formation following facial advancement in CD, focusing on management strategies. CSF rhinorrhea and encephalocele formation are rare complications of craniofacial advancement procedures. Occult elevations in ICP complicate the prospect of permanent surgical repair, potentially necessitating transcranial repair and the use of CSF shunts. Though no consensus exists regarding the utility of perioperative CSF drains, strong associations exist between elevated ICP and failed surgical repair. Additionally, the anatomic changes in the frontal and ethmoid sinuses after facial advancement present a challenge to endoscopic repair. Otolaryngologists should be aware of the possibility of occult elevations in ICP and sinonasal anatomic abnormalities when repairing CSF rhinorrhea in patients with CD. Clinicians should consider CSF shunt placement and carefully weigh the advantages of the transcranial approach versus endonasal, endoscopic techniques.
Imaging Signs in Spontaneous Intracranial Hypotension: Prevalence and Relationship to CSF Pressure.
Kranz, P G; Tanpitukpongse, T P; Choudhury, K R; Amrhein, T J; Gray, L
2016-07-01
Patients with spontaneous intracranial hypotension often exhibit low CSF pressure and changes on brain MR imaging and/or evidence of CSF leak on myelography. We investigated whether individual imaging signs of spontaneous intracranial hypotension correlate with measured CSF pressure and how frequently these 2 markers of spontaneous intracranial hypotension were concordant. We performed a retrospective, cross-sectional study of 99 subjects with spontaneous intracranial hypotension. Prevalence of brain and myelographic imaging signs of spontaneous intracranial hypotension was recorded. CSF pressure among subjects with or without individual imaging signs was compared by using a 2-tailed t test and ANOVA. Concordance between low CSF pressure (≤6 cm H2O) and imaging was defined as the presence of the sign in a subject with low CSF pressure or absence of the sign when pressure was not low. Dural enhancement, brain sagging, and venous distension sign were present in 83%, 61%, and 75% of subjects, respectively, and myelographic evidence of CSF leak was seen in 55%. Marginal correlations between CSF pressure and brain sagging (P = .046) and the venous distension sign (P = .047) were found. Dural enhancement and myelographic evidence of leak were not significantly correlated with CSF pressure. Rates of concordance between imaging signs and low CSF pressure were generally low, ranging from 39% to 55%. Brain and myelographic signs of spontaneous intracranial hypotension correlate poorly with CSF pressure. These findings reinforce the need to base the diagnosis of spontaneous intracranial hypotension on multiple diagnostic criteria and suggest the presence of patient-specific variables that influence CSF pressure in these individuals. © 2016 by American Journal of Neuroradiology.
Felbaum, Daniel R; Anaizi, Amjad; Mason, Robert B; Jean, Walter C; Voyadzis, Jean M
2016-01-01
Introduction: Suboccipital craniotomy is a workhorse neurosurgical operation for approaching the posterior fossa but carries a high risk of pseudomeningocele and cerebrospinal fluid (CSF) leak. We describe our experience with a simple T-shaped fascial opening that preserves the occipital myofascial cuff as compared to traditional methods to reduce this risk. Methods: A single institution, retrospective review of prospectively collected database was performed of patients that underwent a suboccipital craniectomy or craniotomy. Patient data was reviewed for craniotomy or craniectomy, dural graft, and/or sealant use as well as CSF complications. A pseudomeningocele was defined as a subcutaneous collection of cerebrospinal fluid palpable clinically and confirmed on imaging. A CSF leak was defined as a CSF-cutaneous fistula manifested by CSF leaking through the wound. All patients underwent regular postoperative visits of two weeks, one month, and three months. Results: Our retrospective review identified 33 patients matching the inclusion criteria. Overall, our cohort had a 21% (7/33) rate of clinical and radiographic pseudomeningocele formation with 9% (3/33) requiring surgical revision or a separate procedure. The rate of clinical and radiographic pseudomeningocele formation in the myofascial cuff preservation technique was less than standard techniques (12% and 31%, respectively). Revision or further surgical procedures were also reduced in the myofascial cuff preservation technique vs. the standard technique (6% vs 13%). Conclusions: Preservation of the myofascial cuff during posterior fossa surgery is a simple and adoptable technique that reduces the rate of pseudomeningocele formation and CSF leak as compared with standard techniques. PMID:28133584
Spontaneous nasal cerebrospinal fluid leaks and empty sella syndrome: a clinical association.
Schlosser, Rodney J; Bolger, William E
2003-01-01
Spontaneous, idiopathic nasal meningoencephaloceles are herniations of arachnoid/dura and cerebrospinal fluid (CSF) through anatomically fragile sites within the skull base. Empty sella syndrome occurs when intracranial contents herniate through the sellar diaphragm filling the sella turcica with CSF and giving the radiographic appearance of an absent pituitary gland. The objective of this study was to examine the association between spontaneous encephaloceles/CSF leaks and empty sella syndrome because of their similar clinical features and potential common pathophysiology. Retrospective. Sixteen patients were treated for spontaneous encephaloceles between 1996 and 2001. All 16 patients had associated CSF leaks. Five patients had multiple simultaneous encephaloceles. Fifteen patients with imaging of the sella turcica had empty (10 patients) or partially empty (5 patients) sellas. One patient did not have complete imaging of the sella. Three patients had lumbar punctures with measurement of CSF pressure during computed tomography cisternograms because of multiple skull base defects. Mean CSF pressure was 28.3 cm of water (range, 19-34 cm; normal, 0-15 cm). Thirteen of 16 patients (81%) were obese women (mean body mass index 35.9 kg/m2; normal, <25 kg/m2). Mean follow-up was 14.2 months with 100% success in closure of the defects after one procedure. Spontaneous meningoencephaloceles and CSF leaks are strongly associated with radiographic findings of an empty sella and suggest a common pathophysiology. The underlying condition probably represents a form of intracranial hypertension that exerts hydrostatic pressure at anatomically weakened sites within the skull base. Otolaryngologists should be familiar with this disease entity and the implications intracranial hypertension has on patient management.
A short review on a complication of lumbar spine surgery: CSF leak.
Menon, Sajesh K; Onyia, Chiazor U
2015-12-01
Cerebrospinal fluid (CSF) leak is a common complication of surgery involving the lumbar spine. Over the past decades, there has been significant advancement in understanding the basis, management and techniques of treatment for post-operative CSF leak following lumbar spine surgery. In this article, we review previous work in the literature on the various factors and technical errors during or after lumbar spine surgery that may lead to this feared complication, the available options of management with focus on the various techniques employed, the outcomes and also to highlight on the current trends. We also discuss the presentation, factors contributing to its development, basic concepts and practical aspects of the management with emphasis on the different techniques of treatment. Different outcomes following various techniques of managing post-operative CSF leak after lumbar spine surgery have been well described in the literature. However, there is currently no most ideal technique among the available options. The choice of which technique to be applied in each case is dependent on each surgeon's cumulative experience as well as a clear understanding of the contributory underlying factors in each patient, the nature and site of the leak, the available facilities and equipment. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Water Best Management Practice #3 Fact Seet: Outlines how a leak detection and repair program helped Kirtland Air Force Base perform distribution system audits, leak detection, and repair to conserve water site-wide.
Spontaneous CSF-leaks and meningoencephaloceles in sphenoid sinus by persisting Sternberg's canal.
Tomazic, Peter Valentin; Stammberger, Heinz
2009-12-01
Cerebrospinal fluid (CSF) leaks and meningoencephaloceles of the lateral recess of sphenoid sinuses are rare findings. A congenital bony defect in the lateral wall of sphenoid sinus called Sternberg's canal could be the origin of these lesions. Their endoscopic transnasal management is challenging though less traumatic than transcranial approaches. The aim of this study was to define Sternberg's canal as a potential source for these rare lesions and to describe their endoscopic endonasal management. In a retrospective analysis clinical charts of 27 patients with CSF-leaks and / or meningoencephaloceles operated between March 2002 and October 2008 at the University ENT-hospital Graz have been reviewed. All patients were treated by an endoscopic endonasal approach. Five patients (4 female / 1 male) were identified with spontaneous CSF-leaks from sphenoid sinus and meningoencephaloceles. In all five cases, Sternberg's canal was the site of leakage, with the bony and dural defects always located laterally between the maxillary and Vidian nerves. Mean age was 51.2 years and mean body mass index (BMI) was 31.9 kg/m2. All patients were operated using a multilayer closure technique. Two patients had recurrences after 12 days and 7 months, respectively, managed by endoscopic revision surgery resulting in a 100% closure rate after one revision (mean follow-up: 6.5 months). Persisting Sternberg's canal can be the source of spontaneous CSF-leaks and meningoencephaloceles in the lateral recess of sphenoid sinus especially when associated with extensive pneumatisation. Endoscopic management is technically challenging, nevertheless its advantages are a good view of the surgical field while being less traumatic than transcranial approaches.
Autogenous Metallic Pipe Leak Repair in Potable Water Systems.
Tang, Min; Triantafyllidou, Simoni; Edwards, Marc A
2015-07-21
Copper and iron pipes have a remarkable capability for autogenous repair (self-repair) of leaks in potable water systems. Field studies revealed exemplars that metallic pipe leaks caused by nails, rocks, and erosion corrosion autogenously repaired, as confirmed in the laboratory experiments. This work demonstrated that 100% (N = 26) of 150 μm leaks contacting representative bulk potable water in copper pipes sealed autogenously via formation of corrosion precipitates at 20-40 psi, pH 3.0-11.0, and with upward and downward leak orientations. Similar leaks in carbon steel pipes at 20 psi self-repaired at pH 5.5 and 8.5, but two leaks did not self-repair permanently at pH 11.0 suggesting that water chemistry may control the durability of materials that seal the leaks and therefore the permanence of repair. Larger 400 μm holes in copper pipes had much lower (0-33%) success of self-repair at pH 3.0-11.0, whereas all 400 μm holes in carbon steel pipes at 20 psi self-repaired at pH 4.0-11.0. Pressure tests indicated that some of the repairs created at 20-40 psi ambient pressure could withstand more than 100 psi without failure. Autogenous repair has implications for understanding patterns of pipe failures, extending the lifetime of decaying infrastructure, and developing new plumbing materials.
Nakamura, Hiroshi; Matsuyama, Yukihiro; Yoshihara, Hisatake; Sakai, Yoshihito; Katayama, Yoshito; Nakashima, Shojiro; Takamatsu, Jyunki; Ishiguro, Naoki
2005-07-01
A prospective randomized study evaluating the efficacy of autologous fibrin tissue adhesive for decreasing postoperative cerebrospinal fluid (CSF) leak in spinal cord surgery. To compare postoperative CSF leak in 3 groups (i.e., autologous fibrin tissue adhesive used, commercial fibrin glue used, and no fibrin tissue adhesive used) of patients undergoing spinal surgery who needed dural incision. Spinal cord operations, particularly when dural incision is inevitable, sometimes involve postoperative CSF leak. Because CSF leak is a serious complication, countermeasure is necessary to prevent it after dural suture. Commercial fibrin tissue adhesive was formerly used. Because the possibility of prion infection was widely noticed, commercial fibrin tissue adhesive containing animal components has been used less often. In 13 of 39 cases in which dural incision would be made, 400 mL whole blood was drawn, and autologous fibrin tissue adhesive was made of plasma. Cases were divided into 3 groups: (1) dural closure alone, (2) use of autologous fibrin tissue adhesive after dural closure, and (3) use of commercial fibrin tissue adhesive after dural closure. The primary outcome measure was determined as postoperative (3 days) volume of drainage fluid, and results were analyzed using the analysis of variance. The secondary outcome measure was general blood test, coagulation assay, and plasma fibrinogen, and these were analyzed also using the analysis of variance. There was a significant difference in the primary outcome between the autologous and control groups. No complications such as infection or continuous CSF leak were observed in any case. The mean volume of drainage fluid was 586.2 mL in the group with autologous fibrin tissue adhesive and 1026.1 mL in the group without fibrin tissue adhesive. The volume of drainage fluid was significantly lower in the former group than that in the latter group. There was no statistical difference between the volumes of the group with autologous adhesive and with commercial adhesive (639.2 mL). We used autologous fibrin tissue adhesive as a new sealant after dural closure instead of commercial fibrin tissue adhesive. No definitive CSF leak was observed, and the volume of drainage fluid was significantly lower in the group with autologous fibrin tissue adhesive than that in the group without fibrin tissue adhesive. The use of autologous fibrin tissue adhesive was superior to that of commercial fibrin tissue adhesive in cost.
Guppy, Kern H; Silverthorn, James W
2017-04-01
Spinal cord herniation (SCH) is rare, is mostly idiopathic, and occurs predominantly in the thoracic spine. SCH is less common in the cervical spine and has been reported after posterior cervical spine surgery associated with the development of pseudomeningoceles. Two cases of SCH have been reported after anterior cervical corpectomies for ossified posterior longitudinal ligament with cerebrospinal fluid (CSF) leaks. We report the third such case, but the first in a patient without ossified posterior longitudinal ligament (degenerative disc disease and pseudarthrosis). A 56-year-old woman presented with bilateral arm pain and weakness. She had undergone 3 previous anterior cervical spine surgeries at an outside medical center with the most recent 7 years ago with C5 and C6 corpectomies and fusion with a persistent CSF leak. Magnetic resonance imaging and computed tomography myelography showed spinal cord herniation through the mesh cage at C6. The patient underwent a redo C5 and C6 corpectomy with untethering of the spinal cord. The patient was asymptomatic 2 years later. This is the first reported case of anterior cervical SCH in a patient without ossified posterior longitudinal ligament after multiple anterior cervical fusions including a cervical corpectomy for pseudarthrosis with a CSF leak. We hypothesize that persistent CSF leak causes a pressure gradient across the dura mater through the cage to the lower pressure in the retropharyngeal space, which led to herniation of the spinal cord into the anterior cage. We review the literature and discuss the treatment choices for anterior cervical SCH. Copyright © 2017 Elsevier Inc. All rights reserved.
40 CFR 63.11501 - What are the notification, recordkeeping, and reporting requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
... receiver, and each delay of leak repair beyond 45 days for any heat exchange system with a cooling water..., demonstrations of indications of leaks that do not constitute leaks, repairs, and reasons for any delay in repair..., as specified in §§ 63.11496(f)(4) and 63.11410(g), and keep records of bag leak detection systems, as...
Code of Federal Regulations, 2010 CFR
2010-07-01
... VHAP service-skip period leak detection and repair. 61.243-2 Section 61.243-2 Protection of Environment... AIR POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) § 61.243-2 Alternative standards for valves in VHAP service—skip period leak detection and repair. (a)(1) An owner or...
Leak testing and repair of fusion devices
NASA Astrophysics Data System (ADS)
Kozman, T. A.
1983-06-01
The leak testing, reporting and vacuum leak repair techniques of the MPTF yin-yang number one magnet system, the world's largest superconducting magnet system, are discussed. Based on this experience, techniques are developed for testing and repairing leaks on the 42 MPTF-B magnets. The leak hunting techniques for the yin-yang magnet systems were applied to two helium circuits (the coil bundle and guard vacuum; both require helium flow for magnet cooldown). Additionally, during MPTF-B operation there are warm water plasma shields and piping that require leak checking.
Code of Federal Regulations, 2013 CFR
2013-07-01
... process equipment associated with the leaking heat exchanger. You must document the basis for the... the repair as soon as practical. (3) Calculate the potential emissions from the leaking heat exchanger... substances) in the cooling water from the leaking heat exchanger by the flow rate of the cooling water from...
Code of Federal Regulations, 2012 CFR
2012-07-01
... process equipment associated with the leaking heat exchanger. You must document the basis for the... the repair as soon as practical. (3) Calculate the potential emissions from the leaking heat exchanger... substances) in the cooling water from the leaking heat exchanger by the flow rate of the cooling water from...
Code of Federal Regulations, 2014 CFR
2014-07-01
... process equipment associated with the leaking heat exchanger. You must document the basis for the... the repair as soon as practical. (3) Calculate the potential emissions from the leaking heat exchanger... substances) in the cooling water from the leaking heat exchanger by the flow rate of the cooling water from...
Code of Federal Regulations, 2010 CFR
2010-07-01
... process equipment associated with the leaking heat exchanger. You must document the basis for the... the repair as soon as practical. (3) Calculate the potential emissions from the leaking heat exchanger... substances) in the cooling water from the leaking heat exchanger by the flow rate of the cooling water from...
Code of Federal Regulations, 2011 CFR
2011-07-01
... process equipment associated with the leaking heat exchanger. You must document the basis for the... the repair as soon as practical. (3) Calculate the potential emissions from the leaking heat exchanger... substances) in the cooling water from the leaking heat exchanger by the flow rate of the cooling water from...
What is the optimal management of an intra-operative air leak in a colorectal anastomosis?
Mitchem, J B; Stafford, C; Francone, T D; Roberts, P L; Schoetz, D J; Marcello, P W; Ricciardi, R
2018-02-01
An airtight anastomosis on intra-operative leak testing has been previously demonstrated to be associated with a lower risk of clinically significant postoperative anastomotic leak following left-sided colorectal anastomosis. However, to date, there is no consistently agreed upon method for management of an intra-operative anastomotic leak. Therefore, we powered a noninferiority study to determine whether suture repair alone was an appropriate strategy for the management of an intra-operative air leak. This is a retrospective cohort analysis of prospectively collected data from a tertiary care referral centre. We included all consecutive patients with left-sided colorectal or ileorectal anastomoses and evidence of air leak during intra-operative leak testing. Patients were excluded if proximal diversion was planned preoperatively, a pre-existing proximal diversion was present at the time of surgery or an anastomosis was ultimately unable to be completed. The primary outcome measure was clinically significant anastomotic leak, as defined by the Surgical Infection Study Group at 30 days. From a sample of 2360 patients, 119 had an intra-operative air leak during leak testing. Sixty-eight patients underwent suture repair alone and 51 underwent proximal diversion or anastomotic reconstruction. The clinically significant leak rate was 9% (6/68; 95% CI: 2-15%) in the suture repair alone arm and 0% (0/51) in the diversion or reconstruction arm. Suture repair alone does not meet the criteria for noninferiority for the management of intra-operative air leak during left-sided colorectal anastomosis. Further repair of intra-operative air leak by suture repair alone should be reconsidered given these findings. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.
Liu, J; Mei, L Y; He, C F; Feng, Y
2016-11-01
Objective: To assess the diversity of spontaneous cerebrospinal fluid(CSF)otorrhear in clinical manifestation,CT,leakage sites and surgical operation between young children and adults. Method: We conducted a retrospective study of 6 consecutive patients who were all underwent the surgery through the transmastoid approach,including 4 adults patients and 2 children.In the 4 adults patients,two patients' bony defects lay on the tegmen mastoideum,one lay on the tegmen tympani,and another one lay on the sinus meningioma angle.None of the 4 adults patients had abnormal inner ear structures.Materials used in repair included free muscle graft,temporalis fascia,and fibrin glue of the 4 adults patients.The 2 children patients were diagnosed with congenital abnormalities of the lateral inner ear,who had bony defects of the foot plate or fenestra vestibule.Materials used in repair included free muscle graft,temporalis fascia,and musclein sequence. Result: No CSF leaks recurred after the operation except one adults patient,who's left ear recurred two times and experienced three operations. Conclusion: The clinical manifestations of spontaneous CSF otorrhea between young children and adults are different,the HRCT scan on temporal bone before the operation is very important.Especially foradults patients,making sure of theleakagesites and numbers isvaluable and significance for thesurgical procedure selection.. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.
Perioperative lumbar drain utilization in transsphenoidal pituitary resection.
Alharbi, Shatha; Harsh, Griffith; Ajlan, Abdulrazag
2018-01-01
To evaluate lumbar drain (LD) efficacy in transnasal resection of pituitary macroadenomas in preventing postoperative cerebrospinal fluid (CSF) leak, technique safety, and effect on length of hospital stay. We conducted a retrospective data review of pituitary tumor patients in our institution who underwent surgery between December 2006 and January 2013. All patients were operated on for complete surgical resection of pituitary macroadenoma tumors. Patients were divided into 2 groups: group 1 received a preoperative drain, while LD was not preoperatively inserted in group 2. In cases of tumors with suprasellar extension with anticipation of high-flow leak, LD was inserted after the patient was intubated and in a lateral position. Lumbar drain was used for 48 hours, and the drain was removed if no leak was observed postoperatively. In documented postoperative CSF leak patients with no preoperative drain, the leak was treated by LD trial prior to surgical reconstruction. Cases in which leak occurred 6 months postoperatively were excluded. Our study population consisted of 186 patients, 99 women (53%) and 87 men (47%), with a mean age of 50.3+/-16.1 years. Complications occurred in 7 patients (13.7%) in group 1 versus 21 (15.5%) in group 2 (p=0.72). Postoperative CSF leak was observed in 1 patient (1.9%) in group 1 and 7 (5%) in group 2 (Fisher exact test=0.3). Length of hospital stay was a mean of 4.7+/-1.9 days in group 1 and a mean of 2.7+/-2.4 days in group 2 (p<001). The most common reason to extend hospital stay was management of diabetes insipidus. Although LD insertion is generally considered safe with a low risk of complications, it increases the length of hospitalization. Minor complications include headaches and patient discomfort.
Sasaki, T; Akagi, R; Akatsu, Y; Fukawa, T; Hoshi, H; Yamamoto, Y; Enomoto, T; Sato, Y; Nakagawa, R; Takahashi, K; Yamaguchi, S; Sasho, T
2017-03-01
The aim of this study was to investigate the effect of granulocyte-colony stimulating factor (G-CSF) on mesenchymal stem cell (MSC) proliferation in vitro and to determine whether pre-microfracture systemic administration of G-CSF (a bone marrow stimulant) could improve the quality of repaired tissue of a full-thickness cartilage defect in a rabbit model. MSCs from rabbits were cultured in a control medium and medium with G-CSF (low-dose: 4 μg, high-dose: 40 μg). At one, three, and five days after culturing, cells were counted. Differential potential of cultured cells were examined by stimulating them with a osteogenic, adipogenic and chondrogenic medium.A total of 30 rabbits were divided into three groups. The low-dose group (n = 10) received 10 μg/kg of G-CSF daily, the high-dose group (n = 10) received 50 μg/kg daily by subcutaneous injection for three days prior to creating cartilage defects. The control group (n = 10) was administered saline for three days. At 48 hours after the first injection, a 5.2 mm diameter cylindrical osteochondral defect was created in the femoral trochlea. At four and 12 weeks post-operatively, repaired tissue was evaluated macroscopically and microscopically. The cell count in the low-dose G-CSF medium was significantly higher than that in the control medium. The differentiation potential of MSCs was preserved after culturing them with G-CSF.Macroscopically, defects were filled and surfaces were smoother in the G-CSF groups than in the control group at four weeks. At 12 weeks, the quality of repaired cartilage improved further, and defects were almost completely filled in all groups. Microscopically, at four weeks, defects were partially filled with hyaline-like cartilage in the G-CSF groups. At 12 weeks, defects were repaired with hyaline-like cartilage in all groups. G-CSF promoted proliferation of MSCs in vitro . The systemic administration of G-CSF promoted the repair of damaged cartilage possibly through increasing the number of MSCs in a rabbit model. Cite this article : T. Sasaki, R. Akagi, Y. Akatsu, T. Fukawa, H. Hoshi, Y. Yamamoto, T. Enomoto, Y. Sato, R. Nakagawa, K. Takahashi, S. Yamaguchi, T. Sasho. The effect of systemic administration of G-CSF on a full-thickness cartilage defect in a rabbit model MSC proliferation as presumed mechanism: G-CSF for cartilage repair. Bone Joint Res 2017;6:123-131. DOI: 10.1302/2046-3758.63.BJR-2016-0083. © 2017 Sasho et al.
Vehicle-based Methane Mapping Helps Find Natural Gas Leaks and Prioritize Leak Repairs
NASA Astrophysics Data System (ADS)
von Fischer, J. C.; Weller, Z.; Roscioli, J. R.; Lamb, B. K.; Ferrara, T.
2017-12-01
Recently, mobile methane sensing platforms have been developed to detect and locate natural gas (NG) leaks in urban distribution systems and to estimate their size. Although this technology has already been used in targeted deployment for prioritization of NG pipeline infrastructure repair and replacement, one open question regarding this technology is how effective the resulting data are for prioritizing infrastructure repair and replacement. To answer this question we explore the accuracy and precision of the natural gas leak location and emission estimates provided by methane sensors placed on Google Street View (GSV) vehicles. We find that the vast majority (75%) of methane emitting sources detected by these mobile platforms are NG leaks and that the location estimates are effective at identifying the general location of leaks. We also show that the emission rate estimates from mobile detection platforms are able to effectively rank NG leaks for prioritizing leak repair. Our findings establish that mobile sensing platforms are an efficient and effective tool for improving the safety and reducing the environmental impacts of low-pressure NG distribution systems by reducing atmospheric methane emissions.
Dural diverticulum with a symptomatic cerebrospinal fluid leak.
Armstrong, Nicholas; Williamson, Clinton; Williamson, Natalie; Fortes, Manuel; Tjauw, Iwan; Vij, Vikas; Trojan, Ryan
2016-03-01
A case report of a 63-year-old female patient with a cervical spinal dural diverticulum and intracranial hypotension secondary to a symptomatic CSF leak after minor trauma. The patient responded well after the cervical approach epidural blood patch procedure.
Thomas, Regi; Girishan, Shabari; Chacko, Ari George
2016-12-01
Objective To describe the technique of endoscopic transmaxillary temporalis muscle flap transposition for the repair of a persistent postoperative sphenoidal cerebrospinal fluid leak. Design The repair of a recurrent cerebrospinal fluid leak for a patient who had undergone endoscopic transsphenoidal excision of an invasive silent corticotroph Hardy C and Knosp Grade IV pituitary adenoma was undertaken. The patient had completed postoperative radiotherapy for the residual tumor and presented with cerebrospinal fluid leak, 1 year later. The initial two attempts to repair the cerebrospinal fluid leak with free grafts failed. Therefore, an endoscopic transmaxillary transposition of the temporalis muscle flap was attempted to stop the cerebrospinal fluid leak. Results The endoscopic transmaxillary transposition of the vascularized temporalis muscle flap onto the cerebrospinal fluid leak repair site resulted in successful closure of the cerebrospinal fluid leak. Conclusion Endoscopic transmaxillary transposition of the temporalis flap resulted in closure of recurrent cerebrospinal fluid leak in a patient with recurrent pituitary adenoma, who had undergone previous surgery and radiotherapy. This technique has advantages over the endoscopic transpterygoid transposition of the same flap and could be used as a complementary technique in selected patients.
Sotomayor-González, Arturo; Díaz-Martínez, Armando José; Radillo-Gil, Ramón; García-Estrada, Everardo; Morales-Gómez, Jesús Alberto; Palacios-Ortiz, Isaac Jair; Pérez-Cárdenas, Samuel; Arteaga-Treviño, Mauricio; De León, Ángel Martínez-Ponce
2016-01-01
Objective Report a modification of the “rescue flap” technique using a direct endonasal approach with a partial superior septectomy for approaching pituitary tumors developed in our institution. Design Prospective study. Setting Hospital Universitario “Dr. José Eleuterio González,” Universidad Autónoma de Nuevo León. Main Outcome Measures Since April 2015, we have performed 19 cases employing a direct endonasal approach with partial superior septectomy. Results and a technical note are described below. Results Nineteen patients were included in this report. Six patients presented transoperatory cerebrospinal fluid (CSF) leak, so a nasoseptal rescue flap was harvested. No patients developed postoperative CSF leak in this group. Two patients were submitted to a second surgical procedure. Nasoseptal flap was harvested without complications. In both patients, the size of the flap was enough to cover the dural defect and avoid CSF leak. Conclusion Direct endonasal approach with a partial posterior septectomy allows enough exposition of the sphenoidal sinus while preserving the nasoseptal septum with the possibility of a successful rescue flap when needed. PMID:28321383
Sotomayor-González, Arturo; Díaz-Martínez, Armando José; Radillo-Gil, Ramón; García-Estrada, Everardo; Morales-Gómez, Jesús Alberto; Palacios-Ortiz, Isaac Jair; Pérez-Cárdenas, Samuel; Arteaga-Treviño, Mauricio; De León, Ángel Martínez-Ponce
2017-04-01
Objective Report a modification of the "rescue flap" technique using a direct endonasal approach with a partial superior septectomy for approaching pituitary tumors developed in our institution. Design Prospective study. Setting Hospital Universitario "Dr. José Eleuterio González," Universidad Autónoma de Nuevo León. Main Outcome Measures Since April 2015, we have performed 19 cases employing a direct endonasal approach with partial superior septectomy. Results and a technical note are described below. Results Nineteen patients were included in this report. Six patients presented transoperatory cerebrospinal fluid (CSF) leak, so a nasoseptal rescue flap was harvested. No patients developed postoperative CSF leak in this group. Two patients were submitted to a second surgical procedure. Nasoseptal flap was harvested without complications. In both patients, the size of the flap was enough to cover the dural defect and avoid CSF leak. Conclusion Direct endonasal approach with a partial posterior septectomy allows enough exposition of the sphenoidal sinus while preserving the nasoseptal septum with the possibility of a successful rescue flap when needed.
Sasaki, T.; Akagi, R.; Akatsu, Y.; Fukawa, T.; Hoshi, H.; Yamamoto, Y.; Enomoto, T.; Sato, Y.; Nakagawa, R.; Takahashi, K.; Yamaguchi, S.
2017-01-01
Objectives The aim of this study was to investigate the effect of granulocyte-colony stimulating factor (G-CSF) on mesenchymal stem cell (MSC) proliferation in vitro and to determine whether pre-microfracture systemic administration of G-CSF (a bone marrow stimulant) could improve the quality of repaired tissue of a full-thickness cartilage defect in a rabbit model. Methods MSCs from rabbits were cultured in a control medium and medium with G-CSF (low-dose: 4 μg, high-dose: 40 μg). At one, three, and five days after culturing, cells were counted. Differential potential of cultured cells were examined by stimulating them with a osteogenic, adipogenic and chondrogenic medium. A total of 30 rabbits were divided into three groups. The low-dose group (n = 10) received 10 μg/kg of G-CSF daily, the high-dose group (n = 10) received 50 μg/kg daily by subcutaneous injection for three days prior to creating cartilage defects. The control group (n = 10) was administered saline for three days. At 48 hours after the first injection, a 5.2 mm diameter cylindrical osteochondral defect was created in the femoral trochlea. At four and 12 weeks post-operatively, repaired tissue was evaluated macroscopically and microscopically. Results The cell count in the low-dose G-CSF medium was significantly higher than that in the control medium. The differentiation potential of MSCs was preserved after culturing them with G-CSF. Macroscopically, defects were filled and surfaces were smoother in the G-CSF groups than in the control group at four weeks. At 12 weeks, the quality of repaired cartilage improved further, and defects were almost completely filled in all groups. Microscopically, at four weeks, defects were partially filled with hyaline-like cartilage in the G-CSF groups. At 12 weeks, defects were repaired with hyaline-like cartilage in all groups. Conclusions G-CSF promoted proliferation of MSCs in vitro. The systemic administration of G-CSF promoted the repair of damaged cartilage possibly through increasing the number of MSCs in a rabbit model. Cite this article: T. Sasaki, R. Akagi, Y. Akatsu, T. Fukawa, H. Hoshi, Y. Yamamoto, T. Enomoto, Y. Sato, R. Nakagawa, K. Takahashi, S. Yamaguchi, T. Sasho. The effect of systemic administration of G-CSF on a full-thickness cartilage defect in a rabbit model MSC proliferation as presumed mechanism: G-CSF for cartilage repair. Bone Joint Res 2017;6:123–131. DOI: 10.1302/2046-3758.63.BJR-2016-0083. PMID:28258115
The use of image-guidance during transsphenoidal pituitary surgery in the United States
Chung, Thomas K.; Riley, Kristen O.
2015-01-01
Background: Intraoperative image guidance is a useful modality for transsphenoidal pituitary surgery. However, the outcomes associated with this technology have not been systematically evaluated. Objective: The purpose of the study was to quantify complication rates with and without the use of image guidance during transsphenoidal pituitary surgery using a nationwide database with broadly applicable results. Methods: A retrospective analysis of the Nationwide Inpatient Sample was performed from 2007 to 2011. Transsphenoidal pituitary resections for adenomas were identified by International Classification of Diseases-9th Revision, Clinical Modification code. The effect of image guidance on cerebrospinal fluid (CSF) leak complications and cost-benefit was analyzed. Results: A total of 48,848 transsphenoidal pituitary resections were identified, of which 77.5% were partial resections and 22.5% were complete. Pathologic indications included benign (89.3%), malignant primary (0.6%), and malignant secondary (0.4%). Complications included same-stay death (0.4%), CSF leak (8.8%), postoperative CSF rhinorrhea (1.9%), diabetes insipidus (12.4%), and meningitis (0.4%). Image guidance was employed in 7% (n = 3401) of all cases. When analyzed by modality, computed tomography (CT)-assisted procedures had lower CSF rhinorrhea rates (1.1%) compared with cases with no image guidance (1.9%), whereas magnetic resonance (MR)-assisted procedures had the highest rates (2.7%, χ2 p < 0.001). Rates of CSF leak demonstrated a similar pattern (CT 6.4%, no image guidance 8.9%, MR 9.2%, χ2 p < 0.001). CT-assisted surgery had significantly shorter length of stay (2.9 days) versus no image guidance (3.7 days, p < 0.001), lower total charges ($47,589 versus $62,629, p < 0.001), and lower total cost ($16,748 versus $20,530, p < 0.001). Conclusions: CT-assisted surgery is associated with a lower rate of CSF leak, shorter length of stay, and lower cost compared with patients without image guidance. Further studies that control for severity and extent of disease are warranted to confirm this finding. PMID:25975254
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-04-01
When piping develops leaks, the natural instinct is to shut the process down, purge the lines and call in maintenance crews to make the repairs. There is, however, an alternative: on-the-fly repairs. Through the use of specialized tools, equipment and technicians, shut-off valves can be installed and leaks repaired without interrupting production. The split sleeve offers one of the simpler approaches to on-the-fly repairs. Two half cylinders with inside diameter slightly larger than the outside diameter slightly larger than the outside diameter of the pipe to be repaired are slipped over the latter some distance form the leak and looselymore » bolted together. The cylinder is then slid over the leaking area and the bolts tightened. Gaskets inside the half cylinders provide the needed seal between the pipe and the cylinder. Installing a shut-off valve in an operating pipeline requires much more specialized equipment and skills than does repairing a leak with a split sleeve. A device available from International Piping Services Co. allows a trained crew to isolate a section of pipe, drill out the isolated portion, install a blocking valve and then remove the isolation system--all while continuing to operate the pipeline at temperatures to 700 F and pressures to 700 psi. But Herb Porter, CEO of Ipsco, cautions that unlike the repairing leaks with a split sleeve, installing a blocking valve on-the-fly always demands the services of a highly trained crew.« less
Brand, Y; Lim, E; Waran, V; Prepageran, N
2015-12-01
Endoscopic endonasal techniques have recently become the method of choice in dealing with cerebrospinal fluid leak involving the anterior cranial fossa. However, most surgeons prefer an intracranial approach when leaks involve the middle cranial fossa. This case report illustrates the possibilities of using endoscopic techniques for cerebrospinal fluid leaks involving the middle fossa. A 37-year-old male patient presented with multiple areas of cranial defect with cerebrospinal fluid leak due to osteoradionecrosis following radiation for nasopharyngeal carcinoma 4 years earlier. Clinical examination showed involvement of all cranial nerves except the IInd and XIth nerves on the left side. A prior attempt to repair the cerebrospinal fluid leak with craniotomy was not successful. This case demonstrates the successful endoscopic repair of a large cranial defect with cerebrospinal fluid leak.
Kranz, Peter G; Amrhein, Timothy J; Gray, Linda
2017-12-01
The objective of this study is to describe the anatomic and imaging features of CSF venous fistulas, which are a recently reported cause of spontaneous intracranial hypotension (SIH). We retrospectively reviewed the records of patients with SIH caused by CSF venous fistulas who received treatment at our institution. The anatomic details of each fistula were recorded. Attenuation of the veins involved by the fistula was compared with that of adjacent control veins on CT myelography (CTM). Visibility of the CSF venous fistula on CTM and a modified conventional myelography technique we refer to as dynamic myelography was also compared. Twenty-two cases of CSF venous fistula were identified. The fistulas were located between T4 and L1. Ninety percent occurred without a concurrent epidural CSF leak. In most cases (82%), the CSF venous fistula originated from a nerve root sleeve diverticulum. On CTM, the abnormal veins associated with the CSF venous fistula were seen in a paravertebral location in 45% of cases, centrally within the epidural venous plexus in 32%, and lateral to the spine in 23%. Differences in attenuation between the fistula veins and the control veins was highly statistically significant (p < 0.0001), with a threshold of 70 HU perfectly discriminating fistulas from normal veins in our series. When both CTM and dynamic myelography were performed, the fistula was identified on both modalities in 88% of cases. CSF venous fistulas are an important cause of SIH that can be detected on both CTM and dynamic myelograph y and may occur without an epidural CSF leak. Familiarity with the imaging characteristics of these lesions is critical to providing appropriate treatment to patients with SIH.
Cerebrospinal fluid otorhinorrhea due to cochlear dysplasias.
Syal, Rajan; Tyagi, Isha; Goyal, Amit
2005-07-01
Cochlear dysplasia associated with defect in stapes footplate can be a cause of cerebrospinal fluid leak. Repair of cerebrospinal fluid leak in these cases is usually done by packing the vestibule with muscle or fascia. This traditional method of repair has 30-60% failure rate. Cerebrospinal fluid leak in four such patients was successfully repaired using multiple layer packing of vestibule, reinforced by pedicle temporalis muscle graft. Intraoperatively continuous lumbar drain was done. Magnetic resonance imaging of inner ear using 3D FSE T2WI and 3D FIESTA sequences was found helpful noninvasive investigation to localize site and route of cerebrospinal fluid leak.
Eide, Per K; Ringstad, Geir
2018-01-01
The glymphatic system plays a key role for clearance of waste solutes from the rodent brain. We recently found evidence of glymphatic circulation in the human brain when using magnetic resonance imaging (MRI) contrast agent as cerebrospinal fluid (CSF) tracer in conjunction with multiple MRI acquisitions (gMRI). The present study explored the hypothesis that reduced glymphatic clearance in entorhinal cortex (ERC) may be instrumental in idiopathic normal pressure hydrocephalus (iNPH) dementia. gMRI acquisitions were obtained over a 24-48 h time span in cognitively affected iNPH patients and non-cognitively affected patients with suspected CSF leaks. The CSF tracer enrichment was determined as changes in normalized MRI T1 signal units. The study included 30 patients with iNPH and 8 individuals with suspected CSF leaks (i.e. reference individuals). Compared to reference individuals, iNPH patients presented with higher medial temporal lobe atrophy score and Evan's index and inferior ERC thickness. We found delayed clearance of the intrathecal CSF tracer gadobutrol from CSF, the ERC and adjacent white matter, suggesting impaired glymphatic circulation. Reduced clearance and accumulation of toxic waste product such as amyloid-β may be a mechanism behind dementia in iNPH. Glymphatic MRI (gMRI) may become a tool for assessment of early dementia.
Comprehensive leak detection survey and benefit/cost analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scholze, R.J. Jr.; Maloney, S.W.
1995-06-01
Fort Carson, Colorado was the site of a comprehensive leak detection investigation of the potable water system with the express purpose of quantifying the benefits to be derived by a military installation from use of leak detection and repair technology. Military bases are often the size of a small city and one Directorate or Department has responsibility for all real estate (buildings, roads, grounds, etc.) unlike a municipal public works department. The investigation used state of the art noise correlation and computer correlation technology to survey the distribution system mains. This was complemented by a building to building survey coveringmore » office and commercial buildings along with family and barracks housing where investigators entered buildings and quantified visible leaks in faucets and water closets, etc. Following repairs and a year`s time, a follow-on survey is performed to again examine all aspects of the system. The result was a complete economic evaluation and benefit/cost analysis of the installation. Representative findings include: the majority of distribution system leaks were at hydrants or similar appurtenances; and family housing was found to be the other major concentration of leaks. However, where the first survey found 80 percent of housing units had leaks, findings from the second round on the order of 20 percent. Office buildings were found from the first survey to not merit follow-on attention due to limited numbers of leaks. Water-consciousness was raised for both the responsible directorate and individuals in family housing and leak repair was given a higher priority for repairs. This paper will outline the leak detection methodology used, characterize the types and patterns of leaks found, introduce an economic analysis for the entire leak detection process, and finally, provide lessons learned with practical results and implications.« less
Frontotemporal brain sagging syndrome
Wicklund, M.R.; Mokri, B.; Drubach, D.A.; Boeve, B.F.; Parisi, J.E.
2011-01-01
Background: Behavioral variant frontotemporal dementia (bvFTD) is a relatively well-defined clinical syndrome. It is associated with frontal and temporal lobe structural/metabolic changes and pathologic findings of a neurodegenerative disease. We have been evaluating patients with clinical and imaging features partially consistent with bvFTD but with evidence also suggestive of brain sagging, which we refer to as frontotemporal brain sagging syndrome (FBSS). Methods: Retrospective medical chart review to identify all patients seen at our institution between 1996 and 2010, who had a clinical diagnosis of FTD and imaging evidence of brain sag. Results: Eight patients, 7 male and 1 female, were diagnosed with FBSS. The median age at symptom onset was 53 years. All patients had insidious onset and slow progression of behavioral and cognitive dysfunction accompanied by daytime somnolence and headache. Of the 5 patients with functional imaging, all showed evidence of hypometabolism of the frontotemporal regions. On brain MRI, all patients had evidence of brain sagging with distortion of the brainstem; 3 patients had diffuse pachymeningeal enhancement. CSF opening pressure was varied and CSF protein was mildly elevated. A definite site of CSF leak was not identified by myelogram or cisternography, except in one patient with a site highly suggestive of leak who subsequently underwent surgery confirming a CSF leak. In 2 patients with a neuropathologic examination, there was no evidence of a neurodegenerative disease. Conclusions: This case series demonstrates that FBSS may mimic typical bvFTD but should be recognized as an unusual presentation that is potentially treatable. PMID:21502595
Ayhan, Baris; Erikoglu, Mehmet; Tavli, Süleyman S; Toy, Hatice
2012-08-04
Anastomotic leaks constitute one of the most serious intraoperative complications and although many studies have been devoted to finding a solution for this problem, none of them has yet been able offer a decisive, successful method. In this study, the ability of fibrin glue and adhesive film to repair anastomotic leaks in an experimental model was compared. The sample comprised four groups of seven rats: Group 1 (Control): the distal colon was transected and anastomosis was performed. Group 2 (Primary repair): incomplete anastomosis produced a leak that was closed by primary repair on day 3. Group 3 (Fibrin glue): incomplete anastomosis produced a leak that was closed by primary repair and fibrin glue applied on day 3. Group 4 (Adhesive film): incomplete anastomosis produced a leak that was closed by primary repair and adhesive film was applied on day 3. The rats were sacrificed on day 6 following anastomosis. Anastomotic blast compressions were measured and fibroblast activation, inflammation, neovascularization and levels of collagen were evaluated. The results from Group 4 showed that blast compression values were high and statistically significantly increased over control values (p < 0.05). Inflammation in Group 2 was significantly higher than the other groups (p < 0.05). No significant differences were detected in the comparison of the groups regarding the other scoring criteria (p > 0.05). Adhesive film is more effective in reducing anastomotic leakage than fibrin glue.
Endoscopic endonasal surgery for benign fibro-osseous lesions of the pediatric skull base.
Stapleton, Amanda L; Tyler-Kabara, Elizabeth C; Gardner, Paul A; Snyderman, Carl H
2015-09-01
To describe the presentation, treatment, and outcomes of benign fibro-osseous tumors involving the skull base in a pediatric population. Retrospective chart review from January 2002 to September 2013 of pediatric patients (ages 0-18 years) who underwent endoscopic endonasal surgery (EES) for benign fibro-osseous tumors involving the skull base. Fourteen patients were identified with an age range of 2.7 to 17.9 years (mean, 12.5 years). Six juvenile ossifying fibromas, five benign fibro-osseous lesions, two osteomas, and one fibrous dysplasia were treated. Ocular symptoms and nasal obstruction were the most common presenting symptoms in nine (64%) and six (43%) of patients, respectively; five (36%) presented with proptosis and four (29%) with diplopia. Two (14%) patients had cranial nerve VI palsy. Transsellar and transclival approaches were used in five (36%) of patients. Orbital and optic nerve decompressions were the most common components of the approaches performed in nine (64%) of the surgeries. Gross total resection (GTR) was achieved with single-stage surgery in 10 (71%) patients; two additional patients underwent staged GTR. Two intraoperative cerebrospinal fluid (CSF) leaks occurred and were repaired endoscopically. There were no postoperative CSF leaks or infectious complications. Two patients had transient diplopia, and two had transient diabetes insipidus, all of which resolved. The mean follow-up was 13.8 months. Two patients had a recurrence, and both required additional EES achieving GTR. EES for benign fibro-osseous tumors of the skull base is a safe and effective treatment for excision of these lesions in the pediatric population. 4. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
40 CFR 63.454 - Recordkeeping requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... defect or leak is not repaired within 15 days after discovery; (9) The expected date of successful repair of the defect or leak if the repair is not completed within 15 days; (10) The date of successful... 15 minutes. (f) The owner or operator of an open biological treatment system complying with § 63.453...
40 CFR 63.454 - Recordkeeping requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... defect or leak is not repaired within 15 days after discovery; (9) The expected date of successful repair of the defect or leak if the repair is not completed within 15 days; (10) The date of successful... 15 minutes. (f) The owner or operator of an open biological treatment system complying with § 63.453...
Ectopic Prolactinoma Presenting as Bacterial Meningitis: A Diagnostic Conundrum.
Akinduro, Oluwaseun O; Akinduro, Olutomi T; Gupta, Vivek; Reimer, Ronald; Olomu, Osarenoma
2018-04-01
Prolactinomas may rarely present with meningitis and cerebrospinal fluid (CSF) rhinorrhea secondary to erosion of the wall of the sella turcica. It is even more uncommon for this abnormal communication to be caused by an ectopic prolactinoma arising from the sphenoid sinus and eroding into the sella. This atypical growth pattern makes diagnosis very difficult because there may be no displacement of the normal pituitary gland. The first reported case of a patient with an ectopic prolactinoma originating within the sphenoid sinus presenting primarily with meningitis is presented, and the management strategy and surgical and nonsurgical treatment options are discussed. A 48-year-old woman presented with confusion, low-pressure headache, and fever. A lumbar puncture revealed Streptococcus pneumoniae meningitis, and she was placed on intravenous penicillin G. After initiation of antibiotics, she noticed salty tasting postnasal fluid leakage. Imaging was remarkable for bony erosion of the sphenoid sinus wall by a soft tissue mass growing from within the sinus, with no disruption of the normal pituitary gland. A biopsy was then performed with an endoscopic transnasal transsphenoidal approach, and the CSF leak was repaired with a pedicled nasoseptal flap. The final pathology was prolactinoma, and she was placed on cabergoline. Ectopic prolactinomas may rarely present as meningitis secondary to retrograde transmission of bacteria through a bony defect in the sphenoid sinus, and must be included in the differential diagnosis of any sphenoid sinus mass. Management should first address the infection, followed by surgical repair of the bony defect. Copyright © 2018 Elsevier Inc. All rights reserved.
Burlew, Clay Cothren; Moore, Ernest E; Cuschieri, Joseph; Jurkovich, Gregory J; Codner, Panna; Crowell, Kody; Nirula, Ram; Haan, James; Rowell, Susan E; Kato, Catherine M; MacNew, Heather; Ochsner, M Gage; Harrison, Paul B; Fusco, Cynthia; Sauaia, Angela; Kaups, Krista L
2011-02-01
Use of damage control surgery techniques has reduced mortality in critically injured patients but at the cost of the open abdomen. With the option of delayed definitive management of enteric injuries, the question of intestinal repair/anastomosis or definitive stoma creation has been posed with no clear consensus. The purpose of this study was to determine outcomes on the basis of management of enteric injuries in patients relegated to the postinjury open abdomen. Patients requiring an open abdomen after trauma from January 1, 2002 to December 31, 2007 were reviewed. Type of bowel repair was categorized as immediate repair, immediate anastomosis, delayed anastomosis, stoma and a combination. Logistic regression was used to determine independent effect of risk factors on leak development. During the 6-year study period, 204 patients suffered enteric injuries and were managed with an open abdomen. The majority was men (77%) sustaining blunt trauma (66%) with a mean age of 37.1 years±1.2 years and median Injury Severity Score of 27 (interquartile range=20-41). Injury patterns included 81 (40%) small bowel, 37 (18%) colonic, and 86 (42%) combined injuries. Enteric injuries were managed with immediate repair (58), immediate anastomosis (15), delayed anastomosis (96), stoma (10), and a combination (22); three patients died before definitive repair. Sixty-one patients suffered intra-abdominal complications: 35 (17%) abscesses, 15 (7%) leaks, and 11 (5%) enterocutaneous fistulas. The majority of patients with leaks had a delayed anastomosis; one patient had a right colon repair. Leak rate increased as one progresses toward the left colon (small bowel anastomoses, 3% leak rate; right colon, 3%; transverse colon, 20%; left colon, 45%). There were no differences in emergency department physiology, injury severity, transfusions, crystalloids, or demographic characteristics between patients with and without leak. Leak cases had higher 12-hour heart rate (148 vs. 125, p=0.02) and higher 12-hour base deficit (13.7 vs. 9.7, p=0.04), suggesting persistent shock and consequent hypoperfusion were related to leak development. There was a significant trend toward higher incidence of leak with closure day (χ for trend, p=0.01), with closure after day 5 having a four times higher likelihood of developing leak (3% vs. 12%, p=0.02). Repair or anastomosis of intestinal injuries should be considered in all patients. However, leak rate increases with fascial closure beyond day 5 and with left-sided colonic anastomoses. Investigating the physiologic basis for intestinal vulnerability of the left colon and in the open abdomen is warranted.
Code of Federal Regulations, 2010 CFR
2010-07-01
... gas/vapor service or in light liquid service: skip period leak detection and repair. 264.1062 Section... Emission Standards for Equipment Leaks § 264.1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair. (a) An owner or operator subject to...
Code of Federal Regulations, 2011 CFR
2011-07-01
... gas/vapor service or in light liquid service: skip period leak detection and repair. 264.1062 Section... Emission Standards for Equipment Leaks § 264.1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair. (a) An owner or operator subject to...
Code of Federal Regulations, 2014 CFR
2014-07-01
... gas/vapor service or in light liquid service: skip period leak detection and repair. 265.1062 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair. (a) An owner or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... gas/vapor service or in light liquid service: skip period leak detection and repair. 264.1062 Section... Emission Standards for Equipment Leaks § 264.1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair. (a) An owner or operator subject to...
Code of Federal Regulations, 2011 CFR
2011-07-01
... gas/vapor service or in light liquid service: skip period leak detection and repair. 265.1062 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair. (a) An owner or...
Code of Federal Regulations, 2010 CFR
2010-07-01
... gas/vapor service or in light liquid service: skip period leak detection and repair. 265.1062 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair. (a) An owner or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... gas/vapor service or in light liquid service: skip period leak detection and repair. 264.1062 Section... Emission Standards for Equipment Leaks § 264.1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair. (a) An owner or operator subject to...
Code of Federal Regulations, 2013 CFR
2013-07-01
... gas/vapor service or in light liquid service: skip period leak detection and repair. 265.1062 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair. (a) An owner or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... gas/vapor service or in light liquid service: skip period leak detection and repair. 265.1062 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair. (a) An owner or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... gas/vapor service or in light liquid service: skip period leak detection and repair. 264.1062 Section... Emission Standards for Equipment Leaks § 264.1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair. (a) An owner or operator subject to...
Craniofacial Trauma in Pediatric Patients Following Winnowing Blade Injury-review of Literature
Huliyappa, Harsha; Ojha, Balakrishna; Chandra, Anil; Singh, Sunil Kumar; Srivastava, Chhitij
2018-01-01
In developing countries, during the harvest season, winnower blade injuries occur very frequently in children and results in lifelong disability. Nine children were managed during 1 month, all resulting due to winnower blade induced craniofacial trauma. PubMed search for “fan blade injury” showed two case series and three case reports. In our study, 88% had compound depressed fracture; brain matter leak in 56%, cerebrospinal fluid (CSF) leak alone in 22%. 66.7% had injury involving the frontal bone. Two patients had eye injury with visual loss. Seven underwent debridement craniectomy, five augmentation duroplasty and three contusectomy. All had vegetable material, sand particles. Complications in 66.6% with two cases of CSF leak settled with lumbar drain, one case of CSF otorrohea, 22.2% of wound infection, 44.4% wound dehiscence requiring redebridement and suturing in five patients. Two patients had postoperative seizures, two patients had hemiparesis both improved. Two low Glasgow Coma Scale remained so on postoperative period. One case of subdural empyema needed debridement and duroplasty with glue. No mortality noted. These findings were consistent with previous reports. Follow-up at 1.5 months showed good functional recovery. Early surgery debridement, steps to minimize postoperative infections, identifying putative risk factors early in the management are the principles of a successful treatment regimen. PMID:29682010
Craniofacial Trauma in Pediatric Patients Following Winnowing Blade Injury-review of Literature.
Huliyappa, Harsha; Ojha, Balakrishna; Chandra, Anil; Singh, Sunil Kumar; Srivastava, Chhitij
2018-01-01
In developing countries, during the harvest season, winnower blade injuries occur very frequently in children and results in lifelong disability. Nine children were managed during 1 month, all resulting due to winnower blade induced craniofacial trauma. PubMed search for "fan blade injury" showed two case series and three case reports. In our study, 88% had compound depressed fracture; brain matter leak in 56%, cerebrospinal fluid (CSF) leak alone in 22%. 66.7% had injury involving the frontal bone. Two patients had eye injury with visual loss. Seven underwent debridement craniectomy, five augmentation duroplasty and three contusectomy. All had vegetable material, sand particles. Complications in 66.6% with two cases of CSF leak settled with lumbar drain, one case of CSF otorrohea, 22.2% of wound infection, 44.4% wound dehiscence requiring redebridement and suturing in five patients. Two patients had postoperative seizures, two patients had hemiparesis both improved. Two low Glasgow Coma Scale remained so on postoperative period. One case of subdural empyema needed debridement and duroplasty with glue. No mortality noted. These findings were consistent with previous reports. Follow-up at 1.5 months showed good functional recovery. Early surgery debridement, steps to minimize postoperative infections, identifying putative risk factors early in the management are the principles of a successful treatment regimen.
Repairing Hard-to-Reach Cracks in Heat-Exchanger Tubes
NASA Technical Reports Server (NTRS)
Mills, R. C., Sr.; Duesberg, J.
1986-01-01
Inaccessible leaks repaired from accessible side of tube. Fish-Mouth insert placed in cut in leaky heat-exchanger tube. Insert welded or brazed to tube, and remaining open area of cut patched. Method developed for repairing leaks in nozzle coolant tubes of Space Shuttle main engine. Method also used on other types of tubular heat exchangers.
NASA Astrophysics Data System (ADS)
Nitheesh Kumar, P.; Khan, Vishwas Chandra; Balaganesan, G.; Pradhan, A. K.; Sivakumar, M. S.
2018-04-01
The present study is concerned with the repair of through thickness corrosion or leaking defects in metallic pipelines using a commercially available metallic seal and glass/epoxy composite. Pipe specimens are made with three different types of most commonly occurring through thickness corrosion/leaking defects. The metallic seal is applied over the through thickness corrosion/leaking defect and it is reinforced with glass/epoxy composite overwrap. The main objective of the metallic seal is to arrest the leak at live pressure. After reinforcing the metallic seal with glass/epoxy composite overwrap, the repaired composite wrap is able to sustain high pressures. Burst test is performed for different configurations of metallic seal and optimum configuration of metallic seal is determined. The optimum configurations of metallic seal for three different types of through thickness corrosion/leaking defects are further reinforced with glass/epoxy composite wrap and experimental failure pressure is determined by performing the burst test. An analytical model as per ISO 24817 has been developed to validate experimental results.
Wang, Fei; Devine, Christina L; Edwards, Marc A
2017-08-01
Corrosion inhibitors can affect calcium carbonate precipitation and associated in situ and in-service water distribution pipeline leak repair via clogging. Clogging of 150 μm diameter leak holes represented by glass capillary tubes, in recirculating solutions that are supersaturated with calcite (Ω calcite = 13), demonstrated that Zn, orthophosphate, tripolyphosphate, and hexametaphosphate corrosion/scaling inhibitors hinder clogging but natural organic matter (NOM) has relatively little impact. Critical concentrations of phosphates that could inhibit leak repair over the short-term in one water tested were: tripolyphophate (0.05 mg/L as P) < hexametaphosphate (0.1 mg/L) < orthophosphate (0.3 mg/L). Inhibitor blends (Zn+orthophosphate and Zn+NOM+orthophosphate) had stronger inhibitory effects compared to each inhibitor (Zn, orthophosphate or NOM) alone, whereas Zn+NOM showed a lesser inhibitory effect than its individual component (NOM) alone due to formation of smaller CaCO 3 particles with a much more negative zeta-potential. Overall, increased dosing of corrosion inhibitors is probably reducing the likelihood of scaling and in-service leak repair via clogging with calcium carbonate solids in potable water systems.
Sykes, Kenneth T; Yi, Xiaobin
2013-01-01
Cervical epidural steroid injections, administered either interlaminarly or transforaminally, are common injection therapies used in many interventional pain management practices to treat cervicalgia or cervicobrachial pain secondary to spondylosis or intervertebral disc displacement of the cervical spine. Among the risks associated with these procedures are the risk for inadvertent dural puncture and the development of positional headache from intracranial hypotension. We report the case of a 31-year-old woman with a history of migraine and cervicalgia from cervical spine spondylosis and cervical disc degenerative disease that developed an intractable orthostatic headache accompanied by nausea and vomiting after a therapeutic high cervical intralaminar epidural steroid injection was administered directly to the C1-C2 spinal level. Although the initial magnetic resonance imaging of the brain was unremarkable, a computed tomography myelogram study revealed a massive cerebrospinal fluid (CSF) leak from the cervical spine. Repeated cervical epidural blood patches using a catheter targeted to the high cervical spine (C2) to inject 15 mL of autologous blood was required to totally alleviate her symptoms after she failed conservative therapy. Determining the optimal location or approach to administer an epidural blood patch can be a challenge depending on the location of the CSF leak. Our case demonstrates that targeted cervical epidural blood patch placement using an easily manipulated catheter under fluoroscopic guidance is a safe and effective approach to treat a massive CSF leak in the high cervical spine region caused by prior therapeutic cervical spine epidural steroid injection.
Postural headache in a patient with Marfan's syndrome.
Ferrante, E; Citterio, A; Savino, A; Santalucia, P
2003-09-01
A 26-year-old man with Marfan's syndrome had postural headache. Brain MRI with gadolinium showed diffuse pachymeningeal enhancement. MRI myelography revealed bilateral multiple large meningeal diverticula at sacral nerve roots level. He was suspected to have spontaneous intracranial hypotension syndrome. Eight days later headache improved with bed rest and hydration. One month after the onset he was asymptomatic and 3 months later brain MRI showed no evidence of diffuse pachymeningeal enhancement. The 1-year follow-up revealed no neurological abnormalities. The intracranial hypotension syndrome likely resulted from a CSF leak from one of the meningeal diverticula. In conclusion patients with spinal meningeal diverticula (frequently seen in Marfan's syndrome) might be at increased risk of developing CSF leaks, possibly secondary to Valsalva maneuver or minor unrecognized trauma.
Chidambaram, Swathi; Nair, M Nathan; Krishnan, Shyam Sundar; Cai, Ling; Gu, Weiling; Vasudevan, Madabushi Chakravarthy
2015-12-01
Postoperative central nervous system infections (PCNSIs) are rare but serious complications after neurosurgery. The purpose of this study was to examine the prevalence and causative pathogens of PCNSIs at a modernized, resource-limited neurosurgical center in South Asia. A retrospective analysis was conducted of the medical records of all 363 neurosurgical cases performed between June 1, 2012, and June 30, 2013, at a neurosurgical center in South Asia. Data from all operative neurosurgical cases during the 13-month period were included. Cerebrospinal fluid (CSF) analysis indicated that 71 of the 363 surgical cases had low CSF glucose or CSF leukocytosis. These 71 cases were categorized as PCNSIs. The PCNSIs with positive CSF cultures (9.86%) all had gram-negative bacteria with Pseudomonas aeruginosa (n = 5), Escherichia coli (n = 1), or Klebsiella pneumoniae (n = 1). The data suggest a higher rate of death (P = 0.031), a higher rate of CSF leak (P < 0.001), and a higher rate of cranial procedures (P < 0.001) among the infected patients and a higher rate of CSF leak among the patients with culture-positive infections (P = 0.038). This study summarizes the prevalence, causative organism of PCNSI, and antibiotic usage for all of the neurosurgical cases over a 13-month period in a modernized yet resource-limited neurosurgical center located in South Asia. The results from this study highlight the PCNSI landscape in an area of the world that is often underreported in the neurosurgical literature because of the paucity of clinical neurosurgical research undertaken there. This study shows an increasing prevalence of gram-negative organisms in CSF cultures from PCNSIs, which supports a trend in the recent literature of increasing gram-negative bacillary meningitis. Copyright © 2015 Elsevier Inc. All rights reserved.
40 CFR 63.1085 - What are the general requirements for heat exchange systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... water for the presence of substances that indicate a leak according to § 63.1086. (b) If you detect a leak, repair it according to § 63.1087 unless repair is delayed according to § 63.1088. (c) Keep the...
Wang, Jie; Li, Yongxin; Chen, Shubin; Hao, Xinping
2016-08-01
To investigate the long-term effectiveness of transmastoid lateral semicircular canal approach (TMLSCCA) to repair cerebrospinal fluid (CSF) leakage in children associated with recurrent meningitis and severe congenital inner malformation. A retrospective study was conducted in a university hospital, academic medical center. Fifteen children with recurrent meningitis, secondary to severe congenital inner ear malformation, were included in the study. All of them had CSF associated otorrhea and treated using TLSCCA to repair CSF otorrhea by packing the vestibule with muscle and fascia. Observation of the status of postoperative CSF leakage, recurrence of meningitis and complication were conducted. None of the cases had recurrent meningitis and CSF leakage after their TLSCCA procedure in the follow-up period of 1-8.5 years. One case presented with transient facial nerve paralysis and completely recovered 3 months later. TLSCCA for CSF otorrhea in children with recurrent meningitis secondary to congenital inner ear malformation is an alternative approach that offers some advantages. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Improved mitigation of fugitive emissions of hazardous air pollutants (HAPs), volatile organic compounds (VOCs), and greenhouse gas (GHG) emissions is an important emerging topic in many industrial sectors. Efficacious leak detection and repair (LDAR) programs of the future yiel...
Test/QA Plan for Verification of Leak Detection and Repair Technologies
The purpose of the leak detection and repair (LDAR) test and quality assurance plan is to specify procedures for a verification test applicable to commercial LDAR technologies. The purpose of the verification test is to evaluate the performance of participating technologies in b...
Baril, Donald T; Carroccio, Alfio; Ellozy, Sharif H; Palchik, Eugene; Addis, Michael D; Jacobs, Tikva S; Teodorescu, Victoria; Marin, Michael L
2006-03-01
Spinal cord ischemia after endovascular thoracic aortic repair remains a significant risk. Previous or concomitant abdominal aortic repair may increase this risk. This investigation reviews the occurrence of spinal cord ischemia after endovascular repair of the descending thoracic aorta in patients with previous or concomitant abdominal aortic repair. Over an 8-year period, 125 patients underwent endovascular exclusion of the thoracic aorta at the Mount Sinai Medical Center. Twenty-eight of these patients had previous or concomitant abdominal aortic repair. The 27 patients who underwent staged repairs all had cerebrospinal fluid (CSF) drainage during and following repair. This population was analyzed for the complication of spinal cord ischemia and factors related to its occurrence. Mean follow-up was 19.3 months (range 1-61). Spinal cord ischemia developed in four of the 28 patients (14.3%) who underwent endovascular thoracic aortic repair with previous or concomitant abdominal aortic repair, while one of 97 patients (1.0%) developed ischemia among the remaining thoracic endograft population. One patient with concomitant abdominal aortic repair developed cord ischemia that manifested 12 hr following the procedure. The remaining three patients with previous abdominal aortic repair developed more delayed-onset paralysis ranging from the third postoperative day to 7 weeks following repair. Irreversible cord ischemia occurred in three patients, with full recovery in one patient. Major complications from CSF drainage occurred in one patient (3.7%). Spinal cord ischemia occurred at a markedly higher rate in patients with previous or concomitant abdominal aortic repair. This risk continued beyond the immediate postoperative period. The benefit of perioperative and salvage CSF drainage remains to be determined.
Zwagerman, Nathan T; Geltzeiler, Mathew N; Wang, Eric W; Fernandez-Miranda, Juan C; Snyderman, Carl H; Gardner, Paul A
2018-05-30
We present a case of cerebrospinal fluid (CSF) leak after endoscopic endonasal resection of a large clival chordoma in an obese patient. The leak was at the lower reconstruction at the craniocervical junction and had failed repositioning. Using the V-Loc™ wound closure device (Covidien, New Haven, Connecticut) to suture the nasoseptal flap to the nasopharyngeal fascia, a water-tight seal was created and, along with a lumbar drain, the patient healed successfully.CSF leak after an endoscopic endonasal approach (EEA) to intradural pathologies remains one of the more common complications.1-4 Various closure techniques have been developed5-8 with success in mitigating this risk, but all have their limitations and rely on multiple layers including vascularized flaps like the nasoseptal flap.9-11 Endonasal suturing of graft materials offers the advantage of creating a water-tight seal. We present the use of the V-Loc™ wound closure device (Covidien) to successfully seal a postoperative CSF leak. The absorbable V-Loc™ wound closure device does not require the surgeon to tie knots, which is the most challenging step in a deep, 2-dimensional corridor. The suture is barbed and is anchored by threading the needle through a prefabricated loop at the end of the suture which locks in place. Each throw of the suture through tissue maintains the suture line as the barbs catch the tissue and prevent retraction. After successful closure, the needle can simply be cut off.The V-Loc™ wound closure device (Covidien) is a safe and effective adjunct to reconstruction after endoscopic endonasal skull base surgery as it provides an option for graft/flap suturing.A written release from the patient whose name or likeness is submitted as part of this Work is on file.
49 CFR 177.854 - Disabled vehicles and broken or leaking packages; repairs.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 2 2011-10-01 2011-10-01 false Disabled vehicles and broken or leaking packages; repairs. 177.854 Section 177.854 Transportation Other Regulations Relating to Transportation PIPELINE AND... CARRIAGE BY PUBLIC HIGHWAY Vehicles and Shipments in Transit; Accidents § 177.854 Disabled vehicles and...
49 CFR 177.854 - Disabled vehicles and broken or leaking packages; repairs.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 2 2014-10-01 2014-10-01 false Disabled vehicles and broken or leaking packages; repairs. 177.854 Section 177.854 Transportation Other Regulations Relating to Transportation PIPELINE AND... CARRIAGE BY PUBLIC HIGHWAY Vehicles and Shipments in Transit; Accidents § 177.854 Disabled vehicles and...
49 CFR 177.854 - Disabled vehicles and broken or leaking packages; repairs.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 2 2012-10-01 2012-10-01 false Disabled vehicles and broken or leaking packages; repairs. 177.854 Section 177.854 Transportation Other Regulations Relating to Transportation PIPELINE AND... CARRIAGE BY PUBLIC HIGHWAY Vehicles and Shipments in Transit; Accidents § 177.854 Disabled vehicles and...
49 CFR 177.854 - Disabled vehicles and broken or leaking packages; repairs.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 2 2013-10-01 2013-10-01 false Disabled vehicles and broken or leaking packages; repairs. 177.854 Section 177.854 Transportation Other Regulations Relating to Transportation PIPELINE AND... CARRIAGE BY PUBLIC HIGHWAY Vehicles and Shipments in Transit; Accidents § 177.854 Disabled vehicles and...
Cost-effective fence line and process monitoring systems to support advanced leak detection and repair (LDAR) strategies can enhance protection of public health, facilitate worker safety, and help companies realize cost savings by reducing lost product. The U.S. EPA Office of Re...
Kemp, Chandler E; Ravikumar, Arvind P; Brandt, Adam R
2016-04-19
We present a tool for modeling the performance of methane leak detection and repair programs that can be used to evaluate the effectiveness of detection technologies and proposed mitigation policies. The tool uses a two-state Markov model to simulate the evolution of methane leakage from an artificial natural gas field. Leaks are created stochastically, drawing from the current understanding of the frequency and size distributions at production facilities. Various leak detection and repair programs can be simulated to determine the rate at which each would identify and repair leaks. Integrating the methane leakage over time enables a meaningful comparison between technologies, using both economic and environmental metrics. We simulate four existing or proposed detection technologies: flame ionization detection, manual infrared camera, automated infrared drone, and distributed detectors. Comparing these four technologies, we found that over 80% of simulated leakage could be mitigated with a positive net present value, although the maximum benefit is realized by selectively targeting larger leaks. Our results show that low-cost leak detection programs can rely on high-cost technology, as long as it is applied in a way that allows for rapid detection of large leaks. Any strategy to reduce leakage should require a careful consideration of the differences between low-cost technologies and low-cost programs.
Manual leak detection and repair (LDAR) programs are currently implemented on a regular basis at refinery sites to limit fugitive emissions of volatile organic compounds (VOC). However, LDAR surveys can be time-consuming and are not always cost-effective. Fence line monitoring of...
Penetrating duodenal trauma: A 19-year experience.
Schroeppel, Thomas J; Saleem, Kashif; Sharpe, John P; Magnotti, Louis J; Weinberg, Jordan A; Fischer, Peter E; Croce, Martin A; Fabian, Timothy C
2016-03-01
Multiple techniques are used for repair in duodenal injury ranging from simple suture repair for low-grade injuries to pancreaticoduodenectomy for complicated high-grade injuries. Drains, both intraluminal and extraluminal, are placed variably depending on associated injuries and confidence with the repair. It is our contention that a simplified approach to repair will limit complications and mortality. The major complication of duodenal leak (DL) was the outcome used to assess methods of repair in this study. After early deaths from associated vascular injuries were excluded, patients with a penetrating duodenal injury admitted during a 19-year period ending in 2014 constituted the study population. A total of 125 patients with penetrating duodenal injuries were included. Overall, the leak rate was 8% with two duodenal-related mortalities. No differences were seen in patients who had a DL as compared with no leak with respect to demographics, injury severity, or admission variables. Patients with DL were more likely to have a major vascular injury (60% vs. 23%, p = 0.02) and a combined pancreatic injury (70% vs. 31%, p = 0.03). No differences were identified by repair technique, location, or grade of injury. DLs were more likely to have an extraluminal drain (90% vs. 45%, p = 0.008). Primary suture repair should be the initial approach considered for most injuries. Major vascular injuries and concomintant pancreatic injuries were associated with most leaks; therefore, adjuncts to repair including intraluminal drainage and pyloric exclusion should be considered on the initial operation. Extraluminal drains should be avoided unless required for associated injuries. Therapeutic/care management study, level IV.
PORTABLE IMAGING DEVICES FOR INDUSTRIAL LEAK DETECTION AT PETROLEUM REFINERIES AND CHEMICAL PLANTS
Undiscovered gas leaks, or fugitive emissions, in chemical plants and refinery operations can impact regional air quality as well as being a public health problem. Surveying a facility for potential gas leaks can be a daunting task. Industrial Leak Detection and Repair (LDAR) pro...
Code of Federal Regulations, 2013 CFR
2013-07-01
... lubricant into the lubricated packing. (b) Leak identification removal—(1) Valves in gas/vapor and light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be removed... monitoring. The leak identification on a connector in gas/vapor or light liquid service may be removed after...
Code of Federal Regulations, 2012 CFR
2012-07-01
... lubricant into the lubricated packing. (b) Leak identification removal—(1) Valves in gas/vapor and light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be removed... monitoring. The leak identification on a connector in gas/vapor or light liquid service may be removed after...
Code of Federal Regulations, 2011 CFR
2011-07-01
... lubricant into the lubricated packing. (b) Leak identification removal—(1) Valves in gas/vapor and light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be removed... monitoring. The leak identification on a connector in gas/vapor or light liquid service may be removed after...
Code of Federal Regulations, 2014 CFR
2014-07-01
... lubricant into the lubricated packing. (b) Leak identification removal—(1) Valves in gas/vapor and light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be removed... monitoring. The leak identification on a connector in gas/vapor or light liquid service may be removed after...
Yoshida, Hiroki; Takai, Keisuke; Taniguchi, Makoto
2014-09-01
The purpose of this study was to describe significant CT myelography findings for determination of the leak site and outcome of targeted epidural blood patch (EBP) in patients with spontaneous CSF leaks. During 2005-2013, spontaneous CSF leaks were diagnosed for 12 patients with orthostatic headaches. The patients received targeted EBP on the basis of CT myelography assessments. Computed tomography myelograms revealed ventral extradural collection of contrast medium distributed over multiple spinal levels (average 16 levels). Intraforaminal contrast medium extravasations were observed at multiple spinal levels (average 8.2 levels). For 8 (67%) of 12 patients, spinal lesions were noted around the thecal sac and included calcified discs with osteophytes, an ossified posterior longitudinal ligament, and an ossified yellow ligament; lesions were mostly located ventral to the thecal sac and were in close contact with the dura mater. The levels of these spinal lesions were considered potential leak sites and were targeted for EBP. For the remaining 4 patients who did not have definite spinal lesions around the thecal sac, leak site determination was based primarily on the contrast gradient hypothesis. The authors hypothesized that the concentration of extradural contrast medium would be the greatest and the same as that of intradural contrast medium at the leak site but that it would decrease with increased distance from the leak site according to the contrast gradient. Epidural blood patch was placed at the level of spinal lesions and/or of the greatest and same concentration of contrast medium between the intradural and extradural spaces. For 10 of the 12 patients, the orthostatic headaches decreased significantly within a week of EBP and disappeared within a month. For the remaining 2 patients, headaches persisted and medical treatment was required for several months. For 3 patients, thick chronic subdural hematomas caused severe headaches and/or disturbed consciousness because of the mass effect of the hematomas, which were removed by bur hole drainage surgery. For 1 patient, bur hole drainage before EBP on the day of admission to hospital resulted in subdural tension pneumocephalus. The patient's headache immediately disappeared after EBP, and the hematoma did not recur. The other 2 patients underwent EBP followed by bur hole drainage, which resulted in improvements and disappearance of the hematomas. Over the follow-up period (mean 39 months), no CSF leaks or chronic subdural hematomas had recurred in any patient after EBP; by the final follow-up visit, all patients had returned to their jobs. The most significant finding of this study was that spinal ventral calcified or ossified lesions, which may be associated with a dural tear, were present in approximately 70% of patients. Targeted EBP to these lesions resulted in good outcomes.
Treatment of Temporal Bone Fractures
Diaz, Rodney C.; Cervenka, Brian; Brodie, Hilary A.
2016-01-01
Traumatic injury to the temporal bone can lead to significant morbidity or mortality and knowledge of the pertinent anatomy, pathophysiology of injury, and appropriate management strategies is critical for successful recovery and rehabilitation of such injured patients. Most temporal bone fractures are caused by motor vehicle accidents. Temporal bone fractures are best classified as either otic capsule sparing or otic capsule disrupting-type fractures, as such classification correlates well with risk of concomitant functional complications. The most common complications of temporal bone fractures are facial nerve injury, cerebrospinal fluid (CSF) leak, and hearing loss. Assessment of facial nerve function as soon as possible following injury greatly facilitates clinical decision making. Use of prophylactic antibiotics in the setting of CSF leak is controversial; however, following critical analysis and interpretation of the existing classic and contemporary literature, we believe its use is absolutely warranted. PMID:27648399
Treatment of Temporal Bone Fractures.
Diaz, Rodney C; Cervenka, Brian; Brodie, Hilary A
2016-10-01
Traumatic injury to the temporal bone can lead to significant morbidity or mortality and knowledge of the pertinent anatomy, pathophysiology of injury, and appropriate management strategies is critical for successful recovery and rehabilitation of such injured patients. Most temporal bone fractures are caused by motor vehicle accidents. Temporal bone fractures are best classified as either otic capsule sparing or otic capsule disrupting-type fractures, as such classification correlates well with risk of concomitant functional complications. The most common complications of temporal bone fractures are facial nerve injury, cerebrospinal fluid (CSF) leak, and hearing loss. Assessment of facial nerve function as soon as possible following injury greatly facilitates clinical decision making. Use of prophylactic antibiotics in the setting of CSF leak is controversial; however, following critical analysis and interpretation of the existing classic and contemporary literature, we believe its use is absolutely warranted.
76 FR 46842 - Notice of Lodging of Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-03
..., Section 301(a) of the Clean Water Act, 42 U.S.C. 1311(a), and Section 3005(a) of the Resource Conservation..., Michigan. Under the Consent Decree, Dow will implement an Enhanced Leak Detection and Repair (``LDAR'') Program which imposes leak monitoring and repair requirements more stringent than existing LDAR...
84. Photocopied August 1978. REPAIRING FOREBAY LEAK, NOVEMBER 1907. THE ...
84. Photocopied August 1978. REPAIRING FOREBAY LEAK, NOVEMBER 1907. THE PILE-DRIVER IS DRIVING NEW PILES FOR THE FOREBAY APRON, CLAY BACKFILL AND PLANKING CREWS ARE BUSY AT THE RIGHT. MUCH OF THE FOREBAY FLOOR WAS ALSO REPLANKED AT THIS TIME. (520) - Michigan Lake Superior Power Company, Portage Street, Sault Ste. Marie, Chippewa County, MI
40 CFR 63.7917 - What are my inspection and monitoring requirements for transfer systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... annually inspect the unburied portion of pipeline and all joints for leaks and other defects. In the event that a defect is detected, you must repair the leak or defect according to the requirements of... days after detection and repair shall be completed as soon as possible but no later than 45 calendar...
Combined endoscopic approach in the management of suprasellar craniopharyngioma.
Deopujari, Chandrashekhar E; Karmarkar, Vikram S; Shah, Nishit; Vashu, Ravindran; Patil, Rahul; Mohanty, Chandan; Shaikh, Salman
2018-05-01
Craniopharyngiomas are dysontogenic tumors with benign histology but aggressive behavior. The surgical challenges posed by the tumor are well recognized. Neuroendoscopy has recently contributed to its surgical management. This study focuses on our experience in managing craniopharyngiomas in recent years, highlighting the role of combined endoscopic trans-ventricular and endonasal approach. Ninety-two patients have been treated for craniopharyngioma from 2000 to 2016 by the senior author. A total of 125 procedures, microsurgical (58) and endoscopic (67), were undertaken. Combined endoscopic approach was carried out in 18 of these patients, 16 children and 2 young adults. All of these patients presented with a large cystic suprasellar mass associated with hydrocephalus. In the first instance, they were treated with a transventricular endoscopic procedure to decompress the cystic component. This was followed by an endonasal transsphenoidal procedure for excision within the next 2 to 6 days. All these patients improved after the initial cyst decompression with relief of hydrocephalus while awaiting remaining tumor removal in a more elective setting. Gross total resection could be done in 84% of these patients. Diabetes insipidus was the most common postsurgical complication seen in 61% patients in the immediate period but was persistent in only two patients at 1-year follow-up. None of the children in this group developed morbid obesity. There was one case of CSF leak requiring repair after initial surgery. Peri-operative mortality was seen in one patient secondary to ventriculitis. The patients who benefit most from the combined approach are those who present with raised intracranial pressure secondary to a large tumor with cyst causing hydrocephalus. Intraventricular endoscopic cyst drainage allows resolution of hydrocephalus with restoration of normal intracranial pressure, gives time for proper preoperative work up, and has reduced incidence of CSF leak after transnasal surgery. Combined endoscopic approach thus gives a unique opportunity to remove these lesions more radically with less morbidity.
The effect of granulocyte-colony stimulating factor on rotator cuff healing after injury and repair.
Ross, David; Maerz, Tristan; Kurdziel, Michael; Hein, Joel; Doshi, Shashin; Bedi, Asheesh; Anderson, Kyle; Baker, Kevin
2015-05-01
The failure rate of tendon-bone healing after repair of rotator cuff tears remains high. A variety of biologic- and cell-based therapies aimed at improving rotator cuff healing have been investigated, and stem cell-based techniques have become increasingly more common. However, most studies have focused on the implantation of exogenous cells, which introduces higher risk and cost. We aimed to improve rotator cuff healing by inducing endogenous stem cell mobilization with systemic administration of granulocyte-colony stimulating factor (G-CSF). We asked: (1) Does G-CSF administration increase local cellularity after acute rotator cuff repair? (2) Is there histologic evidence that G-CSF improved organization at the healing enthesis? (3) Does G-CSF administration improve biomechanical properties of the healing supraspinatus tendon-bone complex? (4) Are there micro-MRI-based observations indicating G-CSF-augmented tendon-bone healing? After creation of full-thickness supraspinatus tendon defects with immediate repair, 52 rats were randomized to control or G-CSF-treated groups. G-CSF was administered for 5 days after repair and rats were euthanized at 12 or 19 postoperative days. Shoulders were subjected to micro-MR imaging, stress relaxation, and load-to-failure as well as blinded histologic and histomorphometric analyses. G-CSF-treated animals had significantly higher cellularity composite scores at 12 and 19 days compared with both control (12 days: 7.40 ± 1.14 [confidence interval {CI}, 5.98-8.81] versus 4.50 ± 0.57 [CI, 3.58-5.41], p = 0.038; 19 days: 8.00 ± 1.00 [CI, 6.75-9.24] versus 5.40 ± 0.89 [CI, 4.28-6.51], p = 0.023) and normal animals (12 days: p = 0.029; 19 days: p = 0.019). There was no significant difference between G-CSF-treated animals or control animals in ultimate stress (MPa) and strain, modulus (MPa), or yield stress (MPa) and strain at either 12 days (p = 1.000, p = 0.104, p = 1.000, p = 0.909, and p = 0.483, respectively) or 19 days (p = 0.999, p = 0.964, p = 1.000, p = 0.988, and p = 0.904, respectively). There was no difference in MRI score between G-CSF and control animals at either 12 days (2.7 ± 1.8 [CI, 1.08-4.24] versus 2.3 ± 1.8 [CI, 0.49-4.17], p = 0.623) or 19 days (2.5 ± 1.4 [CI, 1.05-3.94] versus 2.3 ± 1.5 [CI, 0.75-3.91], p = 0.737). G-CSF-treated animals exhibited significantly lower relative bone volume compared with normal animals in the entire humeral head (24.89 ± 3.80 [CI, 20.17-29.60) versus 32.50 ± 2.38 [CI, 29.99-35.01], p = 0.009) and at the supraspinatus insertion (25.67 ± 5.33 [CI, 19.04-32.29] versus 33.36 ± 1.69 [CI, 31.58-35.14], p = 0.027) at 12 days. Further analysis did not reveal any additional significant relationships with respect to regional bone volume or trabecular thickness between groups and time points (p > 0.05). Postoperative stem cell mobilization agents may be an effective way to enhance rotator cuff repair. Future studies regarding the kinetics of mobilization, the homing capacity of mobilized cells to injured tissues, and the ability of homing cells to participate in regenerative pathways are necessary.
Tank Remote Repair System Conceptual Design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kriikku, E.
2002-12-06
This document describes two conceptual designs for a Tank Remote Repair System to perform leak site repairs of double shell waste tank walls (Types I, II, III, and IIIA) from the annulus space. The first concept uses a magnetic wall crawler and an epoxy patch system and the second concept uses a magnetic wall crawler and a magnetic patch system. The recommended concept uses the magnetic patch system, since it is simpler to deliver, easier to apply, and has a higher probability of stopping an active leak.
Mehdi, Elnur; Alkan, Alpay; Yetis, Huseyin; Aralasmak, Ayse; Ozdemir, Huseyin
2014-07-01
During the follow-up of recurrent pneumonia in a 9-month-old girl, rhinorrhea with discharge of a positional and intermittent nature was discovered. Radiological assessment was requested to detect any skull base openings and cerebrospinal fluid (CSF) leakage. T2-weighted MR cisternography showed bilateral inner ear dysplasia, communication of the internal auditory canal with the vestibule, and effusion in the right middle ear. Intrathecal contrast-enhanced MR cisternography revealed a CSF fistula from the right internal auditory canal to the Eustachian tube. The patient was operated upon on the right side, and the presence of a CSF leak near the oval window was confirmed. No adverse effects were seen during the short-term and long-term follow-up. Diagnosing this case required special attention, careful examination, and relevant investigations to find the site of CSF leakage in this patient with bilateral inner ear dysplasia.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1005 Section 63.1005... section are met. (A) A dual mechanical seal system that meets the requirements of § 63.1007(e)(1) will be installed, (B) A pump that meets the requirements of § 63.1007(e)(2) will be installed; or (C) A system that...
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Robotic arm experts begin inspection of a scrape on the surface of the honeycomb shell on Endeavour's robotic arm. The scrape occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22..
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Robotic arm experts get ready for ultrasound testing on Endeavour's robotic arm. A scrape of the honeycomb shell around the arm occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- A piece of the honeycomb shell around Endeavour's robotic arm has been cut to inspect the arm. A scrape of the shell occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Robotic arm experts begin inspection of a scrape on the surface of the honeycomb shell on Endeavour's robotic arm. The scrape occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-14
... ID number EPA-HQ- OECA-2010-0357, to (1) EPA online using www.regulations.gov (our preferred method... leaking equipment, repair methods used to stop the leaks, and dates of repair. The time period for this... correction of a mathematical error. There are no annual capital and O&M costs to the regulated entities...
Repair of Inaccessible Ventral Dural Defect in Thoracic Spine: Double Layered Duraplasty
Lee, Dong-Hyun; Park, Jeong-Ill; Park, Ki-Su; Cho, Dae-Chul; Sung, Joo-Kyung
2016-01-01
We propose a double layered (intradural and epidural patch) duraplasty that utilizes Lyoplant and Duraseal. We examined a 47-year-old woman after decompression for thoracic ossification of posterior longitudinal ligament was performed in another hospital. On postoperative day 7, she complained of weakness in both legs. Postoperative magnetic resonance imaging (MRI) showed cerebrospinal fluid (CSF) collection with cord compression. In the operative field, we found 2 large dural defects on the ventral dura mater. We performed a conventional fat graft with fibrin glue. However, the patient exhibited neurologic deterioration, and a postoperative MRI again showed CSF collection. We performed dorsal midline durotomy and inserted a intradural and epidural Lyoplant patch. She immediately experienced diminishing back pain postoperatively. Her visual analog scale and motor power improved markedly. Postoperative MRIs performed at 2 and 16 months showed no spinal cord compression or CSF leakage to the epidural space. We describe a new technique for double layered duraplasty. Although we do not recommend this technique for all dural repairs, double-layered duraplasty may be useful for repairing large inaccessible dural tears in cases of persistent CSF leakage refractory to conventional management. PMID:27437022
Dannawi, Zaher; Lennon, Shirley Evelyn; Zaidan, Ammar; Khazim, Rabi
2014-11-28
A 28-year-old woman presented with a severe unremitting frontal postural headache associated with photophobia. This started immediately after standing following reaching orgasm during sexual intercourse. Fifty-two days previously, the patient underwent bilateral L4-L5 decompression laminotomies and a left L4-L5 discectomy for excision of a large herniated intervertebral disc. Subarachnoid haemorrhage was excluded with a CT scan. Brain and lumbar MRI showed enhancement of the pachymeninges and a cerebrospinal fluid (CSF) leak into the deep soft tissue planes. Conservative treatment for 5 days failed to alleviate the patient's symptoms. An exploration and repair of a dural tear was performed. Subsequently, the headache subsided but the patient developed a low-grade infection requiring 12 weeks of antibiotics. Six months later the patient was asymptomatic. This is the first case report of a delayed presentation of a dural tear occurring during sexual intercourse following lumbar surgery. 2014 BMJ Publishing Group Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeganathan, Reubendra, E-mail: reubenj@hotmail.com; Kennedy, Peter; MacGowan, Simon
2007-06-15
We describe the case of a 68-year-old man who developed aneurysmal dilatation of the proximal descending thoracic aorta 8 years after repair of a type A dissection. The aneurysm was due to an anastomotic leak at the distal end of the previous repair in the ascending aorta with antegrade perfusion of the false lumen. Surgical repair of the anastomotic leak partially obliterated the false lumen and computed tomography scan demonstrated thrombosis in a large proportion of the false lumen aneurysm. Follow-up with surveillance scans showed persistent filling of this aneurysm due to retrograde flow of blood within the false lumen.more » Coil embolization of the false lumen within the thoracic aorta was performed which successfully thrombosed the aneurysm with a reduction in diameter. Late aneurysm formation may complicate type A dissection repairs during follow-up due to a persistent false lumen, especially if there is an anastomotic leak. This case report describes a strategy to deal with this difficult clinical problem.« less
Frost, Hanna K; Kodama, Akira; Ekström, Per; Dahlin, Lars B
2016-10-15
Exogenous granulocyte-colony stimulating factor (G-CSF) has emerged as a drug candidate for improving the outcome after peripheral nerve injuries. We raised the question if exogenous G-CSF can improve nerve regeneration following a clinically relevant model - nerve transection and repair - in healthy and diabetic rats. In short-term experiments, distance of axonal regeneration and extent of injury-induced Schwann cell death was quantified by staining for neurofilaments and cleaved caspase 3, respectively, seven days after repair. There was no difference in axonal outgrowth between G-CSF-treated and non-treated rats, regardless if healthy Wistar or diabetic Goto-Kakizaki (GK) rats were examined. However, G-CSF treatment caused a significant 13% decrease of cleaved caspase 3-positive Schwann cells at the lesion site in healthy rats, but only a trend in diabetic rats. In the distal nerve segments of healthy rats a similar trend was observed. In long-term experiments of healthy rats, regeneration outcome was evaluated at 90days after repair by presence of neurofilaments, wet weight of gastrocnemius muscle, and perception of touch (von Frey monofilament testing weekly). The presence of neurofilaments distal to the suture line was similar in G-CSF-treated and non-treated rats. The weight ratio of ipsi-over contralateral gastrocnemius muscles, and perception of touch at any time point, were likewise not affected by G-CSF treatment. In addition, the inflammatory response in short- and long-term experiments was studied by analyzing ED1 stainable macrophages in healthy rats, but in neither case was any attenuation seen at the injury site or distal to it. G-CSF can prevent caspase 3 activation in Schwann cells in the short-term, but does not detectably affect the inflammatory response, nor improve early or late axonal outgrowth or functional recovery. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.
THE IMPACT OF PHOSPHATE ON COPPER PITTING CORROSION
Pinhole leaks caused by extensive localized or pitting corrosion of copper pipes is a problem for many homeowners. Pinhole water leaks may result in water damage, mold growth, and costly repairs. A large water system in Florida has been addressing a widespread pinhole leak proble...
Graffeo, Christopher S; Dietrich, August R; Grobelny, Bartosz; Zhang, Meng; Goldberg, Judith D; Golfinos, John G; Lebowitz, Richard; Kleinberg, David; Placantonakis, Dimitris G
2014-08-01
Endoscopic endonasal surgery has been established as the safest approach to pituitary tumors, yet its role in other common skull base lesions has not been established. To answer this question, we carried out a systematic review of reported series of open and endoscopic endonasal approaches to four major skull base tumors: olfactory groove meningiomas (OGM), tuberculum sellae meningiomas (TSM), craniopharyngiomas (CRA), and clival chordomas (CHO). Data from 162 studies containing 5,701 patients were combined and compared for differences in perioperative mortality, gross total resection (GTR), cerebrospinal fluid (CSF) leak, neurological morbidity, post-operative visual function, post-operative anosmia, post-operative diabetes insipidus (DI), and post-operative obesity/hyperphagia. Weighted average rates for each outcome were calculated using relative study size. Our findings indicate similar rates of GTR and perioperative mortality between open and endoscopic approaches for all tumor types. CSF leak was increased after endoscopic surgery. Visual function symptoms were more likely to improve after endoscopic surgery for TSM, CRA, and CHO. Post-operative DI and obesity/hyperphagia were significantly increased after open resection in CRA. Recurrence rates per 1,000 patient-years of follow-up were higher in endoscopy for OGM, TSM, and CHO. Trends for open and endoscopic surgery suggested modest improvement in all outcomes over time. Our observations suggest that endonasal endoscopy is a safe alternative to craniotomy and may be preferred for certain tumor types. However, endoscopic surgery is associated with higher rates of CSF leak, and possibly increased recurrence rates. Prospective study with long-term follow-up is required to verify these preliminary observations.
Starnoni, Daniele; Daniel, Roy Thomas; George, Mercy; Messerer, Mahmoud
2017-01-01
Spontaneous meningoencephaloceles of the lateral sphenoid sinus are rare entities, and their peculiar location represents a surgical challenge due to the importance of a wide exposure and skull base reconstruction. They are thought to arise from the congenital base defect of the lateral sphenoid or in some cases have been postulated to represent a rare manifestation of altered cerebrospinal fluid (CSF) dynamics. We report the first case in the literature of a Chiari malformation type I (CMI) and a lateral sphenoid encephalocele, revising the theoretic etiology and surgical technique of endoscopic repair. A 50-year-old woman with a surgical history of symptomatic CMI presented with episodes of spontaneous CSF rhinorrhea. Radiologic investigations revealed a left mesial temporal encephalocele herniating into the lateral recess of the sphenoid sinus and radiologic features of altered CSF dynamics, which may have played an etiologic role. An endoscopic transpterygoid excision of the encephalocele and multilayer skull base repair were performed. The association of spontaneous lateral sphenoid encephaloceles with CMI is distinctly unusual. Predisposing factors and disruption of CSF dynamics may play a major role in the development of these rare complications in patients with CMI. Because of their distinct location, transethmoid or transpterygoid endoscopic approaches represent an excellent surgical technique to treat these lesions thanks to their wide and direct visualization of the entire skull base defect following the encephalocele excision, allowing an adequate multilayer repair and lateral sphenoid recess occlusion. Copyright © 2016 Elsevier Inc. All rights reserved.
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- An ultrasound device is held at the site where the honeycomb shell around Endeavour's robotic arm has been cut to inspect the arm. A scrape of the shell occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- The opening shown here is the site where the honeycomb shell around Endeavour's robotic arm has been cut to inspect the arm. A scrape of the shell occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
Lumbar Cerebrospinal Fluid Drainage in Endovascular Aortic Repair - Reference Centre Experience.
Martins, Ana Margarida; Silva, Marisa; Castro, Maria de Lurdes; Ferro, Ana
2017-01-01
Spinal cord ischemia (SCI) and the resulting paraplegia are one of the most feared postoperative complications after thoraco-abdominal aortic surgery, with an incidence 4,3-8,0% after thoracic endovascular aortic repair (TEVAR), increasing patients morbi-mortality. Lumbar cerebrospinal fluid (CSF) drainage catheter is recommended as preventive measure in high risk patients. To evaluate the efficiency and safety of CSF drainage catheter as preventive or therapeutic measure in endovascular aortic repair (EAR). Retrospective study in 19 patients submitted to TEVAR or fEVAR (fenestrated endovascular aneurism repair), in whom CSF drainage catheter was used, between January 2010 and March 2017. Collected data regarding demographic, perioperative patients characteristics, neurologic symptoms (NS) and other complications. All patients were submitted to general anesthesia (GA) as result of complexity and length of surgery. Known risk factors (RF) for SCI were taken into account. 19 patients, 89,5% (n=17) male, mean age of 66±9 years. 63,2% were classified as ASA III and 36,8% as ASA IV. 9 patients submitted to TEVAR (47,4%); the remaining were submitted to fEVAR. 73,7 % were programed procedures. There were intraoperative complications in 3 patients: iliac artery (IA) rupture in 2 patients, laceration of the axillary artery in 1 patient, all required surgical repair. All catheters were placed in awake patients, before GA induction, and were left in place 2,5 days. 7 patients needed drainage because of CSF pressure>10mmHg intra- or postoperatively. 3 patients developed early symptoms of SCI (decreased mobility and strength of legs). Complete recovery occurred in all patients, except one who recovered just partially. 1 patient developed late NS: paraparesia on 40th postoperative day (POD) as result of spinal stroke. 30 days mortality was 10,5% (n=2), due to cardiorespiratory arrest- 1 by hypovolemic shock (on 3rd POD), 1 by unknown cause (14th POD). This study was limited by the small sample size. CSF drainage catheter was an efficient measure in prevention and treatment of SCI in this sample, since there was no case of complications due to SCI. CSF drainage seems to be an effective technique in preventing SCI. Further studies are required to determine the effectiveness and compare the different methods available for the prevention of SCI complications.
Blind Leak Detection for Closed Systems
NASA Technical Reports Server (NTRS)
Oelgoetz, Peter; Johnson, Ricky; Todd, Douglas; Russell, Samuel; Walker, James
2003-01-01
The current inspection technique for locating interstitial leaking in the Space Shuttle Main Engine nozzles is the application of a liquid leak check solution in the openings where the interstitials space between the tubing and the structural jacket vent out the aft end of the nozzle, while its cooling tubes are pressurized to 25 psig with Helium. When a leak is found, it is classified, and if the leak is severe enough the suspect tube is cut open so that a boroscope can be inserted to find the leak point. Since the boroscope can only cover a finite tube length and since it is impossible to identify which tube (to the right or left of the identified interstitial) is leaking, many extra and undesired repairs have been made to fix just one leak. In certain instances when the interstitials are interlinked by poor braze bonding, many interstitials will show indications of leaking from a single source. What is desired is a technique that can identify the leak source so that a single repair can be performed. Dr, Samuel Russell and James Walker, both with NASA/MSFC have developed a thermographic inspection system that addresses a single repair approach. They have teamed with Boeing/Rocketdyne to repackage the inspection processes to be suitable to address full scale Shuttle development and flight hardware and implement the process at NASA centers. The methods and results presented address the thermographic identification of interstitial leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera (capable of detecting a delta temperature difference of 0.025 C) is used to record the cooling effects associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner hot wall surface as the nozzle is pressurized, These images are enhanced by digitally subtracting a thermal reference image taken before pressurization. The method provides a non-intrusive way of locating the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation. Other applications for this thermographic inspection system are the Reinforced-Carbon-Carbon (RCC) leading edge of the Space Shuttle orbiter and braze joint integrity.
Khalil, Ayman; Clerkin, James; Mandiwanza, Tafadzwa; Green, Sandra; Javadpour, Mohsen
2016-01-01
Multiple cranial nerves palsies following a posterior fossa exploration confined to an extradural compartment is a rare clinical presentation. This case report describes a young man who developed a unilateral abducens and bilateral facial nerve palsies following a posterior fossa exploration confined to an extradural compartment. There are different theories to explain this presentation, but the exact mechanism remains unclear. We propose that this patient cranial nerve palsies developed following cerebrospinal fluid (CSF) leak, potentially as a consequence of rapid change in CSF dynamics. PMID:26951144
Code of Federal Regulations, 2012 CFR
2012-07-01
... light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be... that monitoring. The leak identification on a connector in gas/vapor or light liquid service may be... or light liquid service that is subject to the provisions of § 63.1027(b)(3)(iv), may be removed...
Code of Federal Regulations, 2011 CFR
2011-07-01
... light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be... that monitoring. The leak identification on a connector in gas/vapor or light liquid service may be... or light liquid service that is subject to the provisions of § 63.1027(b)(3)(iv), may be removed...
Code of Federal Regulations, 2013 CFR
2013-07-01
... light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be... that monitoring. The leak identification on a connector in gas/vapor or light liquid service may be... or light liquid service that is subject to the provisions of § 63.1027(b)(3)(iv), may be removed...
Code of Federal Regulations, 2014 CFR
2014-07-01
... light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be... that monitoring. The leak identification on a connector in gas/vapor or light liquid service may be... or light liquid service that is subject to the provisions of § 63.1027(b)(3)(iv), may be removed...
White gauze test: a novel technique in preventing post-hepatectomy bile leak.
Yugasaravanan, K; Affirul, C A; Zamri, Z; Azlanudin, A; Bong, J J
Post-hepatectomy bile leak may lead to undesired morbidity. Multiple methods have been employed to identify this leak but can be inconclusive and taxing. This novel white gauze test is a simple and reliable method. This is a prospective study performed from January 2010 until March 2011. All open hepatic resection were included. Dry white gauze is compressed onto the transected surface and observed for bile staining. The leaking duct is repaired immediately upon detection. The process is repeated until negative. Drain was removed on postoperative day-5. Post-operative bile leak is defined as: 1. Bilirubin concentration of the drain fluid is 3 times or higher than serum; 2. Presence of intra-abdominal bile collection on imaging and upon drainage; 3. Bile leak demonstrated on postoperative cholangiography. 42 patients were recruited. Seven (16.7%) patients were cirrhotic with Child-Pugh A. White gauze test were positive for intra-operative bile leaks in 29 patients (70%), which were primarily repaired. As a result, there was no postoperative bile leak in this series. One mortality was detected in this series due to postoperative pancreatic fistula and multi organ failure. The White Gauze Test is a useful method for the prevention of bile leakage after hepatic resection. It is safe, quick and cheap.
Graffeo, Christopher S.; Dietrich, August R.; Grobelny, Bartosz; Zhang, Meng; Goldberg, Judith D.; Golfinos, John G.; Lebowitz, Richard; Kleinberg, David; Placantonakis, Dimitris G.
2014-01-01
Endoscopic endonasal surgery has been established as the safest approach to pituitary tumors, yet its role in other common skull base lesions has not been established. To answer this question, we carried out a systematic review of reported series of open and endoscopic endonasal approaches to four major skull base tumors: olfactory groove meningiomas (OGM), tuberculum sellae meningiomas (TSM), craniopharyngiomas (CRA), and clival chordomas (CHO). Data from 162 studies containing 5,701 patients were combined and compared for differences in perioperative mortality, gross total resection (GTR), cerebrospinal fluid (CSF) leak, neurological morbidity, post-operative visual function, post-operative anosmia, post-operative diabetes insipidus (DI), and post-operative obesity/hyperphagia. Weighted average rates for each outcome were calculated using relative study size. Our findings indicate similar rates of GTR and perioperative mortality between open and endoscopic approaches for all tumor types. CSF leak was increased after endoscopic surgery. Visual function symptoms were more likely to improve after endoscopic surgery for TSM, CRA, and CHO. Post-operative DI and obesity/hyperphagia were significantly increased after open resection in CRA. Recurrence rates per 1,000 patient-years of follow-up were higher in endoscopy for OGM, TSM, and CHO. Trends for open and endoscopic surgery suggested modest improvement in all outcomes over time. Our observations suggest that endonasal endoscopy is a safe alternative to craniotomy and may be preferred for certain tumor types. However, endoscopic surgery is associated with higher rates of CSF leak, and possibly increased recurrence rates. Prospective study with long-term follow-up is required to verify these preliminary observations. PMID:24014055
Gandhoke, Gurpreet S; Pease, Matthew; Smith, Kenneth J; Sekula, Raymond F
2017-09-01
To perform a cost-minimization study comparing the supraorbital and endoscopic endonasal (EEA) approach with or without craniotomy for the resection of olfactory groove meningiomas (OGMs). We built a decision tree using probabilities of gross total resection (GTR) and cerebrospinal fluid (CSF) leak rates with the supraorbital approach versus EEA with and without additional craniotomy. The cost (not charge or reimbursement) at each "stem" of this decision tree for both surgical options was obtained from our hospital's finance department. After a base case calculation, we applied plausible ranges to all parameters and carried out multiple 1-way sensitivity analyses. Probabilistic sensitivity analyses confirmed our results. The probabilities of GTR (0.8) and CSF leak (0.2) for the supraorbital craniotomy were obtained from our series of 5 patients who underwent a supraorbital approach for the resection of an OGM. The mean tumor volume was 54.6 cm 3 (range, 17-94.2 cm 3 ). Literature-reported rates of GTR (0.6) and CSF leak (0.3) with EEA were applied to our economic analysis. Supraorbital craniotomy was the preferred strategy, with an expected value of $29,423, compared with an EEA cost of $83,838. On multiple 1-way sensitivity analyses, supraorbital craniotomy remained the preferred strategy, with a minimum cost savings of $46,000 and a maximum savings of $64,000. Probabilistic sensitivity analysis found the lowest cost difference between the 2 surgical options to be $37,431. Compared with EEA, supraorbital craniotomy provides substantial cost savings in the treatment of OGMs. Given the potential differences in effectiveness between approaches, a cost-effectiveness analysis should be undertaken. Copyright © 2017 Elsevier Inc. All rights reserved.
Postoperative esophageal leak management with the Polyflex esophageal stent.
Freeman, Richard K; Ascioti, Anthony J; Wozniak, Thomas C
2007-02-01
Leak after esophageal anastomosis or perforation repair prolongs hospitalization, prevents oral hydration and nutrition, and can produce localized infection or sepsis. This investigation reviews our experience treating postoperative esophageal leaks with the Polyflex esophageal stent (Boston Scientific, Natick, Mass). Over a 30-month period, patients with a postoperative esophageal leak were treated with the Polyflex stent for leak occlusion. Leak occlusion was confirmed by means of esophagraphy. Patients were followed until their stent was removed and their esophageal leak had resolved. Twenty-one patients had 27 stents placed for leak occlusion after esophagectomy (n = 5), esophageal perforation (n = 5), surgical (n = 4) or endoscopic (n = 2) antireflux procedure, and esophageal diverticulectomy (n = 3) or myotomy (n = 2). The mean interval between surgical intervention and stent placement was 12 +/- 8 days (range, 3-31 days). Occlusion of the leak occurred in 20 patients. One patient experienced a dehiscence of the surgical esophageal perforation repair requiring esophageal diversion. Stent migration requiring repositioning (n = 3) or replacement (n = 4) occurred in 5 (24%) patients. Twenty (95%) stents were removed without residual leak (mean, 51 +/- 43 days; range, 15-175 days). One patient had a stricture after stent removal that required endoscopic dilatation. One patient in this series died. The Polyflex esophageal stent is an effective method for occluding a postoperative esophageal leak. It rapidly eliminates contamination of the mediastinum, pleura, and peritoneum; allows oral hydration and nutrition; and is easily removable. These stents also offer an appealing alternative to traditional esophageal diversion and subsequent reconstruction in patients with a persistent esophageal leak.
Marmotti, A; Bonasia, D E; Bruzzone, M; Rossi, R; Castoldi, F; Collo, G; Realmuto, C; Tarella, C; Peretti, G M
2013-08-01
Minced chondral fragments are becoming popular as a source of cells for cartilage repair, as a growing interest is developing towards one-stage procedures to treat cartilage lesions. The purpose of this study is to (A) compare cell outgrowth from cartilage fragments of adult and young donors using two different types of scaffolds and (B) evaluate the influence of transforming-growth-factor-β1 (TGF-β1) and granulocyte colony-stimulating factor (G-CSF) on chondrocyte behaviour. In part (A) cartilage fragments from adult and young donors were either loaded onto an HA-derivative injectable paste scaffold or onto an HA-derivative membrane scaffold. Construct sections were then examined for cell counting after 1, 2 and 3 months. In part (B) only membrane scaffolds were prepared using cartilage fragments from young donors. Constructs were cultured either in standard growth medium or in the presence of specific growth factors, such as TGF-β1 or G-CSF or TGF-β1 + G-CSF. After 1 month, construct sections were examined for cell counting. Expression of chondrocyte markers (SOX9, CD151, CD49c) and proliferative markers (β-catenin, PCNA) was assessed using immunofluorescence techniques, both in unstimulated construct sections and in cells from unstimulated and stimulated construct cultures. Part (A): histological analysis showed age-dependent and time-dependent chondrocyte migration. A significant difference (p < 0.05) was observed between young and older donors at the same time point. No difference was detected between the two types of scaffolds within the same group at the same time point. Part (B): after 1 month, the number of migrating cells/area significantly increased due to exposure to TGF-β1 and/or G-CSF (p < 0.05). Immunofluorescence revealed that outgrowing cells from unstimulated scaffold sections were positive for SOX9, CD151, CD49c and G-CSF receptor. Immunofluorescence of cells from construct cultures showed an increase in β-catenin in all stimulated groups and an increased PCNA expression in G-CSF-exposed cultures (p < 0.05). Outgrowing cells may represent a subset of chondrocytes undergoing a phenotypic shift towards a proliferative state. TGF-β1, and to a greater extent G-CSF, may accelerate this outgrowth. The clinical relevance of this study may involve a potential future clinical application of scaffolds preloaded with growth factors as an additional coating for chondral fragments. Indeed, a controlled delivery of G-CSF, widely employed in various clinical settings, might improve the repair process driven by minced human cartilage fragments during one-stage cartilage repair.
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- One of a team of robotic experts prepares the site scraped on the robotic arm for removal. The scrape occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. The site will be cut out and ultrasound testing will be done on the structure underneath. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
40 CFR 60.482-9a - Standards: Delay of repair.
Code of Federal Regulations, 2010 CFR
2010-07-01
... destroyed or recovered in a control device complying with § 60.482-10a. (d) Delay of repair for pumps will... repair is allowed for a leaking pump, valve, or connector that remains in service, the pump, valve, or...
40 CFR 60.482-9a - Standards: Delay of repair.
Code of Federal Regulations, 2012 CFR
2012-07-01
... destroyed or recovered in a control device complying with § 60.482-10a. (d) Delay of repair for pumps will... repair is allowed for a leaking pump, valve, or connector that remains in service, the pump, valve, or...
40 CFR 60.482-9a - Standards: Delay of repair.
Code of Federal Regulations, 2011 CFR
2011-07-01
... destroyed or recovered in a control device complying with § 60.482-10a. (d) Delay of repair for pumps will... repair is allowed for a leaking pump, valve, or connector that remains in service, the pump, valve, or...
Kourbeti, Irene S; Vakis, Antonis F; Ziakas, Panayiotis; Karabetsos, Dimitris; Potolidis, Evangelos; Christou, Silvana; Samonis, George
2015-05-01
OBJECT The authors performed a prospective study to define the prevalence and microbiological characteristics of infections in patients undergoing craniotomy and to clarify the risk factors for post-craniotomy meningitis. METHODS Patients older than 18 years who underwent nonstereotactic craniotomies between January 2006 and December 2008 were included. Demographic, clinical, laboratory, and microbiological data were systemically recorded. Patient characteristics, craniotomy type, and pre- and postoperative variables were evaluated as risk factors for meningitis RESULTS Three hundred thirty-four procedures were analyzed (65.6% involving male patients). Traumatic brain injury was the most common reason for craniotomy. Almost 40% of the patients developed at least 1 infection. Ventilator-associated pneumonia (VAP) was the most common infection recorded (22.5%) and Acinetobacter spp. were isolated in 44% of the cases. Meningitis was encountered in 16 procedures (4.8%), and CSF cultures were positive for microbial growth in 100% of these cases. Gram-negative pathogens (Acinetobacter spp., Klebsiella spp., Pseudomonas aeruginosa, Enterobacter cloaceae, Proteus mirabilis) represented 88% of the pathogens. Acinetobacter and Klebsiella spp. demonstrated a high percentage of resistance in several antibiotic classes. In multivariate analysis, the risk for meningitis was independently associated with perioperative steroid use (OR 11.55, p = 0.005), CSF leak (OR 48.03, p < 0.001), and ventricular drainage (OR 70.52, p < 0.001). CONCLUSIONS Device-related postoperative communication between the CSF and the environment, CSF leak, and perioperative steroid use were defined as risk factors for meningitis in this study. Ventilator-associated pneumonia was the most common infection overall. The offending pathogens presented a high level of resistance to several antibiotics.
ERIC Educational Resources Information Center
Popke, Michael
2000-01-01
Examines the difficulties and solutions to wet environment repairs in pools and locker rooms. Issues include crack and leak repairs, repairs to grout and tile, on-deck accessories, and underwater lights. Several "tricks-of-the-trade" notes are included as is a brief discussion on emergency shutdowns. (GR)
Italian multicentre study on intrathecal fluorescein for craniosinusal fistulae.
Felisati, G; Bianchi, A; Lozza, P; Portaleone, S
2008-08-01
Cerebrospinal fluid leak (CSF), clinical sign of a dural lesion of the skull base, is a relatively rare event that can present with a variety of symptoms. Every craniosinus fistula should be considered a serious, potentially life-threatening situation (even those cases with hidden CSF leak). Reports of experience concerning diagnosis and treatment of craniosinus fistulae have appeared in the Literature. In the last few years, the endoscopic nasal approach is proving effective as it makes diagnosis much easier and is the least invasive surgical approach, with the greatest percentage of success. Various classifications are being proposed to improve clinical evaluation of CSF leaks and to simplify the diagnostic and therapeutic approach. The most common parameters of classification are: aetiology (traumatic, iatrogenic, non-traumatic, etc.) site, type of flow (high or low pressure) and, as far as concerns treatment, the type of graft used, all of which have contributed to various diagnostic and therapeutic algorithms being proposed. Therefore, the subject seems to be widely schematized and the therapeutic attitude widely agreed. However, one of the diagnostic and therapeutic approaches is now being questioned. For some, it is the heart of the clinical approach, while for others, it is a useful tool yet too dangerous to be used on account of potential side effects: namely, the fluorescein test. This procedure, consisting of intrathecal injection of a colorant (fluorescein), is well known by the Food and Drug Administration (FDA) which neither explicitly prohibits it, nor allows it, intrathecal administration is, therefore, an off label use. As far as the Authors know, authorization of this procedure has not been forthcoming anywhere in the world although the procedure itself is widely employed. As far as concerns the use of intrathecal fluorescein, many scientific papers have been written, clearly supporting its clinical usefulness. One limit to the use of fluorescein derives from frequent reports of complications, often related to the intrathecal administration; such complications are, however, always due to an incorrect dosage. In order to perform correct monitoring of any complication related to the use of intrathecal fluorescein and to investigate in a strictly scientific fashion, the legal problem related to the off label use (intrathecal administration) of an authorised substance, the Authors coordinated an Italian multicentre study aimed at establishig the tolerability of the lumbar intrathecal administration of fluorescein. Aim of the study was to review the literature focusing on CSF leaks, to set up to date diagnostic and therapeutic indications of fluorescein and to report the preliminary results of the Italian multicentre study.
Cerebrospinal fluid rhinorrhea: An institutional perspective from Pakistan.
Tahir, Muhammad Zubair; Khan, Muhammad Babar; Bashir, Muhammad Umair; Akhtar, Shabbir; Bari, Ehsan
2011-01-01
The management of cerebrospinal fluid (CSF) rhinorrhea has evolved over the last two decades. We present here a review of our 11-year data on CSF rhinorrhea and its management at a tertiary care hospital in a developing country, with particular reference to the diagnosis, surgical management and outcome of the disease. The medical charts of all patients with a diagnosis of CSF rhinorrhea over an 11-year period were reviewed. The etiology of CSF rhinorrhea was classified into three categories: spontaneous, iatrogenic and traumatic. All the patients were divided into three categories based on the type of management as conservative, intracranial and transnasal endoscopic groups. A total of 43 patients fulfilled our inclusion criteria and were included in the final analysis. Eleven of the 43 patients were managed conservatively, while 22 underwent intracranial repairs; 10 patients had transnasal endoscopic repairs. The primary success rate for the transnasal approach was 70% compared to 86% for the intracranial repair. Blood loss, special care unit (SCU) stay and total cost were found to be significantly less in the transnasal endoscopic group. Computed tomography (CT) cisternography was found to have the highest sensitivity and specificity. Further, no postoperative complications were found in the transnasal endoscopic group, while five patients from the intracranial group developed various complications. We conclude that the transnasal endoscopic approach has comparable success rates with the intracranial approach and significantly lower morbidity.
CTP (Cochlin-tomoprotein) detection in the profuse fluid leakage (gusher) from cochleostomy.
Ikezono, Tetsuo; Sugizaki, Kazuki; Shindo, Susumu; Sekiguchi, Satomi; Pawankar, Ruby; Baba, Shunkichi; Yagi, Toshiaki
2010-08-01
By testing 125 samples, we confirmed that Cochlin-tomoprotein (CTP) is present in the perilymph, not in cerebrospinal fluid (CSF). Perilymph and CSF exist in two distinct compartments, even in the case of a malformed inner ear with a bony defect in the lamina cribrosa, as described here. Cochleostomy might have suddenly decreased the perilymph pressure, allowing the influx of CSF into the inner ear resulting in profuse fluid leakage, first perilymph then CSF. The first purpose of this study was to further confirm the specificity of the perilymph-specific protein CTP that we reported recently. Secondly, we assessed the nature of the fluid leakage from the cochleostomy using the CTP detection test. A standardized CTP detection test was performed on 65 perilymph and 60 CSF samples. Samples of profuse fluid leakage collected from cochleostomy during cochlear implantation surgery of one patient with branchio-oto-renal (BOR) syndrome were also tested by the CTP detection test. CTP was detected in 60 of 65 perilymph samples but not in any of the CSF samples. The leaked fluid was shown to contain CTP, i.e. perilymph, at the outset, and then the CTP detection signals gradually disappeared as time elapsed.
Cools, Michael J; Quinsey, Carolyn S; Elton, Scott W
2018-04-13
OBJECTIVE The choice of graft material for duraplasty in decompressions of Chiari malformations remains a matter of debate. The authors present a detailed technique for harvesting ligamenta nuchae, as well as the clinical and radiographic outcomes of this technique, in a case series. METHODS The authors conducted a retrospective study evaluating the outcomes of Chiari malformation type I decompression and duraplasty in children aged 0-18 years at a single institution from 2013 to 2016. They collected both intraoperative and postoperative variables and compared them qualitatively to published data. RESULTS During the study period, the authors performed 25 Chiari malformation decompressions with ligamentum nuchae graft duraplasties. Of the 25 patients, 10 were females, and the mean age at surgery was 8.6 years (range 13 months to 18 years). The median operative time was 163 minutes (IQR 152-187 minutes), with approximately 10 minutes needed by a resident surgeon to harvest the graft. The mean length of stay was 3 nights (range 2-6 nights), and the mean follow-up was 12.6 months (range 0.5-43.5 months). One patient (4%) developed a CSF leak that was repaired using an oversewing patch. There were no postoperative pseudomeningoceles or infections. Of the 19 patients presenting with a syrinx, imaging showed improvement in 10 (53%) and 8 (42%) had stable syrinx size on imaging. Of 16 patients presenting with a symptomatic Chiari malformation, 14 (87.5%) experienced resolution of symptoms and in 1 (4%) symptoms remained the same. One patient (4%) presented with worsening syrinx and symptoms 1.5 months after initial surgery and underwent repeat decompression. CONCLUSIONS The authors describe a series of clinical and imaging outcomes of patients who underwent Chiari malformation decompression and duraplasty with a harvested ligamentum nuchae. The rates of postoperative CSF leak are similar to established techniques of autologous and artificial grafts, with similarly successful outcomes. Further study will be needed with larger patient cohorts to more directly compare duraplasty graft outcomes.
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- One of a team of robotic experts looks at the site of the scrape on the surface of the honeycomb shell on the robotic arm that occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. The site will be cut out and ultrasound testing will be done on the structure underneath. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Workers in Endeavour's payload bay look at the site of the scrape on the surface of the honeycomb shell on the robotic arm that occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. The site will be cut out and ultrasound testing will be done on the structure underneath. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- The site being identified in the photo is the scrape on the surface of the honeycomb shell on Endeavour's robotic arm. The scrape occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. The site will be cut out and ultrasound testing will be done on the structure underneath. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
Scrape on Endeavour's robotic arm during oxygen leak repairs
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- One of a team of robotic experts looks at the site of the scrape on the surface of the the robotic arm's honeycomb shell. The scrape occurred while work platforms were being installed to gain access to repair the oxygen leak in Endeavour's mid-body. The site will be cut out and ultrasound testing will be done on the structure underneath. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
[CSF otorrhea: case report and management].
Salmon, C; Demanez, L; Lefèbvre, Ph
2013-01-01
Mr G, sixty-seven years old, was admitted to our hospital for a liver transplant. He suffered from a cirrhosis due to an HBV infection, complicated by an hepatocellular carcinoma. During the perioperative care, a left otorrhea was discovered. According to the clinical history, this otorrhea had been present for six weeks and followed the completion of a myringotomy. The myringotomy had been performed with a view to place a transtympanic ventilation tube for the treatment of a serous otitis media inducing a conductive hearingloss. Clinical, biological, and radiological explorations revealed a CSF leak caused by the fact that the myringotomy had been done in a temporal meningo-encephalocele. A conservative treatment allowed to stop the otorrhea. We present a short discussion about temporal meningoencephalocele and, more generally, about CSF otorrhea.
40 CFR 265.1052 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... week for indications of liquids dripping from the pump seal. (b)(1) If an instrument reading of 10,000... the pump seal, a leak is detected. (c)(1) When a leak is detected, it shall be repaired as soon as... after each leak is detected. (d) Each pump equipped with a dual mechanical seal system that includes a...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Actions for Liquid Mercury Spills and Accumulations and Hydrogen and Mercury Vapor Leaks 3 Table 3 to... Standards—Required Actions for Liquid Mercury Spills and Accumulations and Hydrogen and Mercury Vapor Leaks... cell back into service until the leaking equipment is repaired. 3. A decomposer or hydrogen system...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Actions for Liquid Mercury Spills and Accumulations and Hydrogen and Mercury Vapor Leaks 3 Table 3 to... Standards—Required Actions for Liquid Mercury Spills and Accumulations and Hydrogen and Mercury Vapor Leaks... cell back into service until the leaking equipment is repaired. 3. A decomposer or hydrogen system...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Actions for Liquid Mercury Spills and Accumulations and Hydrogen and Mercury Vapor Leaks 3 Table 3 to... Standards—Required Actions for Liquid Mercury Spills and Accumulations and Hydrogen and Mercury Vapor Leaks... cell back into service until the leaking equipment is repaired. 3. A decomposer or hydrogen system...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Actions for Liquid Mercury Spills and Accumulations and Hydrogen and Mercury Vapor Leaks 3 Table 3 to... Standards—Required Actions for Liquid Mercury Spills and Accumulations and Hydrogen and Mercury Vapor Leaks... cell back into service until the leaking equipment is repaired. 3. A decomposer or hydrogen system...
40 CFR 60.483-2 - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2011 CFR
2011-07-01
... valves in gas/vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0... Industry for which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or... periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to...
40 CFR 60.483-2 - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2012 CFR
2012-07-01
... valves in gas/vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0... Industry for which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or... periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to...
40 CFR 60.483-2 - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2014 CFR
2014-07-01
... valves in gas/vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0... Industry for which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or... periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to...
40 CFR 60.483-2 - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2013 CFR
2013-07-01
... valves in gas/vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0... Industry for which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or... periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to...
40 CFR 60.483-2 - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2010 CFR
2010-07-01
... valves in gas/vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0... Industry for which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or... periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to...
Supraorbital keyhole surgery for optic nerve decompression and dura repair.
Chen, Yuan-Hao; Lin, Shinn-Zong; Chiang, Yung-Hsiao; Ju, Da-Tong; Liu, Ming-Ying; Chen, Guann-Juh
2004-07-01
Supraorbital keyhole surgery is a limited surgical procedure with reduced traumatic manipulation of tissue and entailing little time in the opening and closing of wounds. We utilized the approach to treat head injury patients complicated with optic nerve compression and cerebrospinal fluid leakage (CSF). Eleven cases of basal skull fracture complicated with either optic nerve compression and/or CSF leakage were surgically treated at our department from February 1995 to June 1999. Six cases had primary optic nerve compression, four had CSF leakage and one case involved both injuries. Supraorbital craniotomy was carried out using a keyhole-sized burr hole plus a small craniotomy. The size of craniotomy approximated 2 x 3 cm2. The optic nerve was decompressed via removal of the optic canal roof and anterior clinoid process with high-speed drills. The defect of dura was repaired with two pieces of tensa fascia lata that were attached on both sides of the torn dural defect with tissue glue. Seven cases with optic nerve injury included five cases of total blindness and two cases of light perception before operation. Vision improved in four cases. The CSF leakage was stopped successfully in all four cases without complication. As optic nerve compression and CSF leakage are skull base lesions, the supraorbital keyhole surgery constitutes a suitable approach. The supraorbital keyhole surgery allows for an anterior approach to the skull base. This approach also allows the treatment of both CSF leakage and optic nerve compression. Our results indicate that supraorbital keyhole operation is a safe and effective method for preserving or improving vision and attenuating CSF leakage following injury.
Hiramoto, Jade S; Fernandez, Charlene; Gasper, Warren; Vartanian, Shant; Reilly, Linda; Chuter, Timothy
2017-02-01
Hyperglycemia is associated with worsened clinical outcomes after central nervous system injury. The purpose of this study was to examine the association between lower extremity weakness (LEW) and the glucose levels of blood and cerebrospinal fluid (CSF) in patients undergoing multibranched endovascular aneurysm repair (MBEVAR) of thoracoabdominal and pararenal aortic aneurysms. Blood and CSF samples were collected preoperatively, immediately after aneurysm repair, and on postoperative day 1 in 21 patients undergoing MBEVAR. Data on demographics, operative repair, complications, and outcomes were collected prospectively. There were 21 patients who underwent successful MBEVAR. Two patients had pre-existing paraplegia from prior open aortic surgery and were excluded from the current analysis. The mean age was 73 ± 8 years, and 15 of 19 (79%) were men. In the postoperative period, 7 of 19 (37%) patients developed LEW. This was temporary in 5 of 19 (26%) patients and permanent in 2 of 19 (11%) patients. The LEW group was older than the non-LEW group (77 ± 6 vs 70 ± 9 years, respectively; P = .10), had a lower preoperative glomerular filtration rate (58.6 ± 18.5 vs 71.4 ± 23.5 mL/min per 1.73 m 2 ; P = .24), and was more likely to be taking a statin (100% vs 67%, respectively; P = .13), but these did not reach statistical significance. There was no significant difference in the prevalence of diabetes mellitus, hypertension, coronary artery disease, lung disease, or peripheral artery disease between the LEW and non-LEW groups. There was also no difference in operative time, blood loss, contrast material volume, or fluoroscopy times between the two groups. Preoperative blood and CSF glucose levels were similar in those with and without LEW. During the postoperative period, glucose values in the blood and CSF were significantly higher in those patients who developed LEW compared with those who did not develop LEW. In all patients with LEW, the elevation in the blood or CSF glucose level preceded the development of LEW. In a multivariable logistic regression model, CSF glucose concentration on postoperative day 1 was significantly and independently associated with the development of LEW (odds ratio, 2.30 [1.03-5.14] per 10 mg/dL increase in CSF glucose; P = .04). Elevated blood glucose and CSF glucose levels are associated with postoperative LEW in patients undergoing MBEVAR. The protective effect of euglycemia deserves further study in patients at risk for spinal cord ischemia. Copyright © 2016 Society for Vascular Surgery. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (ii) If delay of repair was caused by depletion of stocked parts, there must be documentation that the spare parts were sufficiently stocked onsite before depletion and the reason for depletion. (5) Dates of...
Amaki, Yoshikiyo; Moriyama, Michihiko; Kuzuta, Toshimichi; Yabe, Keiko; Kaneko, Misato
1997-12-01
This research investigated whether the Sprotte needle causes less leakage of CSF than the Quincke needle in the artificial spinal cord. The changes in intradural pressure, extradural pressure, and leaked volume of CSF were evaluated following puncture with Sprotte and Quincke needles in the artificial spinal cord. The decrease in intradural pressure was 9.7±1.8 mm H 2 O with the Sprotte needle and 20.5±2.7 mm H 2 O with the Quincke needle (P<0.05). The volume of leakage of artificial CSF was 2.0±0.3 ml with the Sprotte needle and 3.3 ±0.3 ml with the Quincke needle (P<0.01). The extradural pressure increase was 166.1±8.2 mm H 2 O with the Sprotte needle and 186.8±13.2 mm H 2 O with the Quincke needle (P<0.05). The Sprotte needle produces less CSF leakage than the Quincke needle.
40 CFR 60.483-2a - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2012 CFR
2012-07-01
.../vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0, the owner or... Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.483... percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the...
40 CFR 60.483-2a - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2014 CFR
2014-07-01
.../vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0, the owner or... Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.483... percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the...
40 CFR 60.483-2a - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2011 CFR
2011-07-01
.../vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0, the owner or... Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.483... percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the...
40 CFR 60.483-2a - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2013 CFR
2013-07-01
.../vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0, the owner or... Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.483... percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the...
40 CFR 60.483-2a - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2010 CFR
2010-07-01
.../vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0, the owner or... Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.483... percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the...
Aortic root repair for thoracic aorta false aneurysm following Bentall procedure.
Kumar, Sanjay; Jones, Steve; Sivananthan, U M; McGoldrick, J P
2008-08-01
The Bentall procedure for aortic root replacement in Marfan's syndrome is safe and durable. We describe successful repair of periprosthetic valvular leak, 12 years following Bentall repair with composite graft. The aim of this report is to analyse and evaluate technical factors leading to this unusual occurrence.
ERIC Educational Resources Information Center
Bednar, Barbara A.
1990-01-01
The harm to human health and our environment caused by leaking underground storage tanks can be devastating. Schools can meet new federal waste management standards by instituting daily inventory monitoring, selecting a reliable volumetric testing company, locating and repairing leaks promptly, and removing and installing tanks appropriately. (MLH)
Oh, Hyuntaek; Yaraghi, Nicholas; Raghavan, Srinivasa R
2015-05-19
Molecular organogelators convert oils into gels by forming self-assembled fibrous networks. Here, we demonstrate that such gelation can be activated by contacting the oil with an immiscible solvent (water). Our gelator is dibenzylidene sorbitol (DBS), which forms a low-viscosity sol when added to toluene containing a small amount of dimethyl sulfoxide (DMSO). Upon contact with water, DMSO partitions into the water, activating gelation of DBS in the toluene. The gel grows from the oil/water interface and slowly envelops the oil phase. We have exploited this effect for the self-repair of oil leaks from underwater tubes. When a DBS/toluene/DMSO solution flows through the tube, it forms a gel selectively at the leak point, thereby plugging the leak and restoring flow. Our approach is reminiscent of wound-sealing via blood-clotting: there also, inactive gelators in blood are activated at the wound site into a fibrous network, thereby plugging the wound and restoring blood flow.
[Management of cerebrospinal fluid leaks according to size. Our experience].
Alobid, Isam; Enseñat, Joaquim; Rioja, Elena; Enriquez, Karla; Viscovich, Liza; de Notaris, Matteo; Bernal-Sprekelsen, Manuel
2014-01-01
We present our experience in the reconstruction of cerebrospinal fluid (CSF) leaks according to their size and location. Fifty-four patients who underwent advanced skull base surgery (large defects) and 62 patients with CSF leaks of different origin (small and medium-sized defects) were included. Large defects were reconstructed with a nasoseptal pedicled flap positioned on fat and fascia lata and lumbar drainage was used. In small and medium-sized leaks of other origin, intrathecal fluorescein 5% was applied previously to identify the defect. Fascia lata in an underlay position was used for reconstruction, which was then covered with mucoperiosteum from the turbinate. Perioperative antibiotics were administered for 5-7 days. Nasal packing was removed after 24-48 hours. The most frequent aetiology for small and medium-sized defects was spontaneous (48.4%), followed by trauma (24.2%), iatrogenic (5%) and others. The success rate was of 91% after the first surgery and 98% in large skull base defects and small/medium-sized respectively. After rescue surgery, the rate of closure achieved was 100%. The follow-up was 15.6 ± 12.4 months for large defects and 75.3 ± 51.3 months for small/medium-sized defects without recurrence. Endoscopic surgery for closure of any type of skull base defect is the gold standard approach. Defect size does not play a significant role in the success rate. Fascia lata and mucoperiosteum allow a reconstruction of small/medium-sized defects. For larger skull base defects, a combination of fat, fascia lata and nasoseptal pedicled flaps provide a successful reconstruction. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Tomoda, Y; Korogi, Y; Aoki, T; Morioka, T; Takahashi, H; Ohno, M; Takeshita, I
2008-03-01
The pathogenesis of cerebrospinal fluid (CSF) hypovolemia is supposed to be caused by CSF leakage through small dural defects. To compare source three-dimensional (3D) fast spin-echo (FSE) images of magnetic resonance (MR) myelography with radionuclide cisternography findings, and to evaluate the feasibility of MR myelography in the detection of CSF leakage. A total of 67 patients who were clinically suspected of CSF hypovolemia underwent indium-111 radionuclide cisternography, and 27 of those who had direct findings of CSF leakage were selected for evaluation. MR myelography with 3D FSE sequences (TR/TE 6000/203 ms) was performed at the lumbar spine for all patients. We evaluated source images and maximum intensity projection (MIP) images of MR myelography, and the findings were correlated with radionuclide cisternography findings. MR myelography of five healthy volunteers was used as a reference. The MR visibility of the CSF leakage was graded as definite (leakage clearly visible), possible (leakage poorly seen), or absent (not shown). CSF leakage was identified with source 3D FSE images in 22 (81.5%) of 27 patients. Of the 22 patients, 16 were graded as definite and six were graded as possible. For the definite cases, 3D FSE images clearly showed the extent of the leaked CSF in the paraspinal structures. In the remaining five patients with absent findings, radionuclide cisternography showed only slight radionuclide activity out of the arachnoid space. Source 3D FSE images of MR myelography seem useful in the detection of CSF leakage. Invasive radionuclide cisternography may be reserved for equivocal cases only.
Khalil, Ayman; Clerkin, James; Mandiwanza, Tafadzwa; Green, Sandra; Javadpour, Mohsen
2016-03-06
Multiple cranial nerves palsies following a posterior fossa exploration confined to an extradural compartment is a rare clinical presentation. This case report describes a young man who developed a unilateral abducens and bilateral facial nerve palsies following a posterior fossa exploration confined to an extradural compartment. There are different theories to explain this presentation, but the exact mechanism remains unclear. We propose that this patient cranial nerve palsies developed following cerebrospinal fluid (CSF) leak, potentially as a consequence of rapid change in CSF dynamics. Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author 2016.
Saldarriaga, Carolina; Lyssikatos, Charlampos; Belyavskaya, Elena; Keil, Margaret; Chittiboina, Prashant; Sinaii, Ninet; Stratakis, Constantine A; Lodish, Maya
2018-04-01
To define the incidence and risk factors of postoperative sodium alterations in pediatric patients undergoing transsphenoidal surgery (TSS) for adrenocorticotropic hormone and growth hormone secreting pituitary adenomas. We retrospectively reviewed 160 patients ≤18 years of age who had TSS for pituitary adenomas at our institution from 1999 to 2017. Variables included daily serum sodium through postoperative day 10, urine specific gravity, and medications administered. We examined associations between sex, repeat surgery, manipulation of the posterior pituitary (PP), tumor invasion into the PP, tumor type and size, cerebrospinal fluid (CSF) leak, lumbar drain insertion, body mass index, puberty, and development of diabetes insipidus (DI) or syndrome of inappropriate antidiuretic hormone secretion (SIADH). Mean age was 12.9 ± 3.4 years (female = 81). Patients had adrenocorticotropic hormone (150/160) and growth hormone (10/160) producing adenomas. Forty-two (26%) patients developed DI. Among the 37 of 160 who required desmopressin acutely, 13 of 37 required it long term. Risk of long-term need for desmopressin was significantly higher in patients who had CSF leak 9 of 48 (P = .003), lumbar drain 6 of 30 (P = .019), manipulation 11 of 50 (P < .001), or invasion 4 of 15 (P = .022) of the PP. Sixty patients developed hyponatremia, 19 because of SIADH, 39 to hypotonic fluids and 2 to cerebral salt wasting syndrome. Patients with SIADH were placed on fluid restriction; 1 received salt tablets. Among 160 children who underwent TSS for pituitary adenomas, the incidence of DI and SIADH after TSS was 26% and 14%, respectively. Combined risk factors for DI and/or SIADH include female sex, manipulation of and/or tumor invasion into the PP, and CSF leak or lumbar drain. ClinicalTrials.gov: NCT00001595 and NCT00060541. Published by Elsevier Inc.
Incidence and Risk Factors for Sigmoid Venous Thrombosis Following CPA Tumor Resection.
Shew, Matthew; Kavookjian, Hannah; Dahlstrom, Kelly; Muelleman, Thomas; Lin, James; Camarata, Paul; Ledbetter, Luke N; Staecker, Hinrich
2018-06-01
Our primary aim was to determine the incidence of sigmoid venous thrombosis (SVT) and determine risks factors and sequelae of SVT following cerebellopontine angle tumor resection. Retrospective cohort study. Academic tertiary care hospital. Patients over 18 years of age who underwent resection of cerebellopontine angle meningioma or vestibular schwannoma from January 2005 to April 2016 who had postoperative magnetic resonance imaging. Diagnostic. Incidence of postoperative sigmoid venous thrombosis (SVT) from official radiology reports was compared with retrospective imaging review by our institutional neuroradiologists. Data collected included age, length of stay, body mass index, surgical approach, and postoperative complications. A total of 127 patients were identified. Official radiology reads significantly underreported the incidence of postoperative SVT compared with retrospective review by our institutional neuroradiologist for patients who underwent routine postoperative imaging (n = 4 [3.1%] versus n = 22 [17.3%]; p < 0.001). There was a statistical trend toward increased risk for thrombosis in patients undergoing translabyrinthine and staged resection that did not reach significance (p = 0.068). Cerebrospinal fluid (CSF) leak incidence in patients with thrombosis was significantly increased (n = 9 [37.5%] versus n = 13 [12.6%]; p = 0.007). When controlling for approach, the presence of thrombus was associated with a more then three-fold increase in odds of CSF leak (OR = 3.28, 95% CI: 1.12-9.48, p = 0.030). There was no correlation between SVT and age (p = 0.788), body mass index (p = 0.686), length of stay (p = 0.733), preoperative tumor size (p = 0.555), or increased postoperative ICP (p = 0.645). Only one patient was symptomatic from sigmoid thrombosis compared with 21 who were not. Incidence of SVT is significantly underreported and may predispose patients to increase risk for CSF leak. Staged and translabyrinthine approaches demonstrate an increased trend toward thrombosis risk. Our findings suggest it may not be necessary to treat asymptomatic SVT.
COPPER PITTING CORROSION AND PINHOLE LEAKS: A CASE STUDY
Localized corrosion, or "pitting", of copper drinking water pipe continues is a problem for many water utilities and their customers. Extreme attack leads to pinhole leaks that can potentially lead to water damage, mold growth, and costly repairs for the homeowners, as well as th...
49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance... pipe in size. (4) If the leak is on a submerged offshore pipeline or submerged pipeline in inland...
Rapid, Vehicle-Based Identification of Location and Magnitude of Urban Natural Gas Pipeline Leaks.
von Fischer, Joseph C; Cooley, Daniel; Chamberlain, Sam; Gaylord, Adam; Griebenow, Claire J; Hamburg, Steven P; Salo, Jessica; Schumacher, Russ; Theobald, David; Ham, Jay
2017-04-04
Information about the location and magnitudes of natural gas (NG) leaks from urban distribution pipelines is important for minimizing greenhouse gas emissions and optimizing investment in pipeline management. To enable rapid collection of such data, we developed a relatively simple method using high-precision methane analyzers in Google Street View cars. Our data indicate that this automated leak survey system can document patterns in leak location and magnitude within and among cities, even without wind data. We found that urban areas with prevalent corrosion-prone distribution lines (Boston, MA, Staten Island, NY, and Syracuse, NY), leaked approximately 25-fold more methane than cities with more modern pipeline materials (Burlington, VT, and Indianapolis, IN). Although this mobile monitoring method produces conservative estimates of leak rates and leak counts, it can still help prioritize both leak repairs and replacement of leak-prone sections of distribution lines, thus minimizing methane emissions over short and long terms.
Acher, Charles Wynn; Ostlie, Daniel J; Leys, Charles M; Struckmeyer, Shannon; Parker, Matthew; Nichol, Peter F
2016-12-01
Introduction Outcome studies of tracheoesophageal fistula (TEF) and/or esophageal atresia (EA) are limited to retrospective chart reviews. This study surveyed TEF/EA patients/parents engaged in social media communities to determine long-term outcomes. Materials and Methods A 50-point survey was designed to study presentation, interventions, and ongoing symptoms after repair in patients with TEF/EA. It was validated using a test population and made available on TEF/EA online communities. Results In this study, 445 subjects completed the survey during a 2-month period. Mean age of patients when surveyed was 8.7 years (0-61 years) and 56% were male. Eighty-nine percent of surveys were completed by the parent of the patient. Sixty-two percent of patients underwent repair in the first 7 days of life. Standard open repair was most common (56%), followed by primary esophageal replacement (13%) and thoracoscopic repair (13%). Out of 405, 106 (26%) patients had postoperative leak. Postoperative leak was least likely in primary esophageal replacement (18%) and standard open repair (19%). Leak occurred in 32% of patients who had thoracoscopic repair; 31% (128/413) reported long-gap atresia, which was significantly associated with increased risk of postoperative leak (54/128, 42%) when compared with standard short-gap atresia (odds ratio, 3.5; p = 0.001). Out of 409, 221 (54%) patients reported dysphagia after repair, with only 77/221 (34.8%) reporting resolution by age 5. Out of 381, 290 (76%) patients reported symptoms of gastroesophageal reflux disease (GERD). There was no difference in dysphagia rates or GERD symptoms based on type of initial repair. Antireflux surgery was required in 63/290, 22% of patients with GERD (15% of all patients) and 27% of these patients who had surgery required more than one procedure antireflux procedure. The most common was Nissen fundoplication (73%), followed by partial wrap (14%). Reflux recurred in 32% of patients after antireflux surgery. Conclusion TEF/EA patients have long-term dysphagia and GERD that may be under reported. Retrospective studies of outcomes after TEF/EA repair may underestimate long-term esophageal dysmotility, dysphagia, GERD, and strictures that occur regardless of the type of repair and adversely affect quality of life. Fifteen percent of all TEF/EA patients surveyed required an antireflux procedure during childhood, and more than one-quarter of those required repeat surgery. These data demonstrate the need for long-term follow-up as pediatric patients transition to adult care. Georg Thieme Verlag KG Stuttgart · New York.
Excluded segmental duct bile leakage: the case for bilio-enteric anastomosis.
Patrono, Damiano; Tandoi, Francesco; Romagnoli, Renato; Salizzoni, Mauro
2014-06-01
Excluded segmental duct bile leak is the rarest type of post-hepatectomy bile leak and presents unique diagnostic and management features. Classical management strategies invariably entail a significant loss of functioning hepatic parenchyma. The aim of this study is to report a new liver-sparing technique to handle excluded segmental duct bile leakage. Two cases of excluded segmental duct bile leak occurring after major hepatic resection were managed by a Roux-en-Y hepatico-jejunostomy on the excluded segmental duct, avoiding the sacrifice of the liver parenchyma origin of the fistula. In both cases, classical management strategies would have led to the functional loss of roughly 50 % of the liver remnant. Diagnostic and management implications are thoroughly discussed. Both cases had an uneventful postoperative course. The timing of repair was associated with a different outcome: the patient who underwent surgical repair in the acute phase developed no long-term complications, whereas the patient who underwent delayed repair developed a late stenosis requiring percutaneous dilatation. Roux-en-Y hepatico-jejunostomy on the excluded bile duct is a valuable technique in selected cases of excluded segmental duct bile leakage.
Fok, M; Bashir, M; Fraser, H; Strouther, N; Mason, A
2015-04-01
Thoraco-abdominal aneurysms (TAAA) represents a particularly lethal vascular disease that without surgical repair carries a dismal prognosis. However, there is an inherent risk from surgical repair of spinal cord ischaemia that can result in paraplegia. One method of reducing this risk is cerebrospinal fluid (CSF) drainage. We believe that the CSF contains clinically significant biomarkers that can indicate impending spinal cord ischaemia. This work therefore presents a novel measurement method for proteins, namely albumin, as a precursor to further work in this area. The work uses an interdigitated electrode (IDE) sensor and shows that it is capable of detecting various concentrations of albumin (from 0 to 100 g/L) with a high degree of repeatability at 200 MHz (R(2) = 0.991) and 4 GHz (R(2) = 0.975).
Buchmann, Stefan; Sandmann, Gunther H; Walz, Lars; Reichel, Thomas; Beitzel, Knut; Wexel, Gabriele; Tian, Weiwei; Battmann, Achim; Vogt, Stephan; Winter, Gerhard; Imhoff, Andreas B
2015-04-10
Biological augmentation of rotator cuff repair is of growing interest to improve biomechanical properties and prevent re-tearing. But intraoperative single shot growth factor application appears not sufficient to provide healing support in the physiologic growth factor expression peaks. The purpose of this study was to establish a sustained release of granulocyte-colony stimulating factor (G-CSF) from injectable vesicular phospholipid gels (VPGs) in vitro and to examine biocompatibility and influence on histology and biomechanical behavior of G-CSF loaded VPGs in a chronic supraspinatus tear rat model. G-CSF loaded VPGs were produced by dual asymmetric centrifugation. In vitro the integrity, stability and release rate were analyzed. In vivo supraspinatus tendons of 60 rats were detached and after 3 weeks a transosseous refixation with G-CSF loaded VPGs augmentation (n = 15; control, placebo, 1 and 10 μg G-CSF/d) was performed. 6 weeks postoperatively the healing site was analyzed histologically (n = 9; H&E by modified MOVIN score/Collagen I/III) and biomechanically (n = 6). In vitro testing revealed stable proteins after centrifugation and a continuous G-CSF release of up to 4 weeks. Placebo VPGs showed histologically no negative side effects on the healing process. Histologically in vivo testing demonstrated significant advantages for G-CSF 1 μg/d but not for G-CSF 10 μg/d in Collagen III content (p = 0.035) and a higher Collagen I/III ratio compared to the other groups. Biomechanically G-CSF 1 μg/d revealed a significant higher load to failure ratio (p = 0.020) compared to control but no significant differences in stiffness. By use of VPGs a continuous growth factor release could be obtained in vitro. The in vivo results demonstrate an improvement of immunohistology and biomechanical properties with a low dose G-CSF application via VPG. The VPG itself was well tolerated and had no negative influence on the healing behavior. Due to the favorable properties (highly adhesive, injectable, biocompatible) VPGs are a very interesting option for biologic augmentation. The study may serve as basis for further research in growth factor application models.
77 FR 34066 - Notice of Lodging of Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-08
... Organic Chemical Manufacturing Industry and Organic Hazardous Air Pollutants for Equipment Leaks). The... Defendants to implement an Enhanced Leak Detection and Repair Program to mitigate any potential excess emissions resulting from past CAA violations; implement controls on an API oil/water separator as additional...
Experiences in Performing Posterior Calvarial Distraction.
McMillan, Kevin; Lloyd, Mark; Evans, Martin; White, Nicholas; Nishikawa, Hiroshi; Rodrigues, Desiderio; Sharp, Melanie; Noons, Pete; Solanki, Guirish; Dover, Stephen
2017-05-01
The use of posterior calvarial distraction (PCD) for the management of craniosynostosis is well recognized. The advantages of using this technique include increased cranial volume, decreased intracranial pressure, relief of posterior fossa crowding, improved cerebrospinal fluid (CSF) circulation at the cranio-cervical junction with cessation, and possible resolution of syrinx.The authors retrospectively review their first 50 patients who have undergone PCD under the senior author's care in our unit.The demographics, diagnoses, intraoperative approach with techniques in distractor placement and outcomes of each patient were obtained through an electronic craniofacial database and written patient records. Analysis of complication rates (bleeding, distraction problems, CSF leaks, and infection) was included.A total of 31 boys and 19 girls underwent the procedure between October 2006 and September 2015 with a median age was 17.7 months (range 4 months to 19 years). Of those 50 children, 34 of the cohort were proven to be syndromic by genetic testing.The median length of inpatient stay was 9.4 days (range 3-43 days). Average distraction distance was 24 mm.Complications including CSF leaks, bleeding, distractor problems, and severe complications (recorded in 3 patients) are discussed. Our overall complication rate was 50%.Favorable outcomes included resolution of Chiari, syrinx, and raised intracranial pressure in the majority of patients where distraction was successful.The authors recommend that PCD should be considered the primary treatment for increasing calvarial volume. The authors discuss our experiences and technical innovations over the past decade.
Ghobrial, George M; Anderson, Paul A; Chitale, Rohan; Campbell, Peter G; Lobel, Darlene A; Harrop, James
2013-10-01
In the era of surgical resident work hour restrictions, the traditional apprenticeship model may provide fewer hours for neurosurgical residents to hone technical skills. Spinal dura mater closure or repair is 1 skill that is infrequently encountered, and persistent cerebrospinal fluid leaks are a potential morbidity. To establish an educational curriculum to train residents in spinal dura mater closure with a novel durotomy repair model. The Congress of Neurological Surgeons has developed a simulation-based model for durotomy closure with the ongoing efforts of their simulation educational committee. The core curriculum consists of didactic training materials and a technical simulation model of dural repair for the lumbar spine. Didactic pretest scores ranged from 4/11 (36%) to 10/11 (91%). Posttest scores ranged from 8/11 (73%) to 11/11 (100%). Overall, didactic improvements were demonstrated by all participants, with a mean improvement between pre- and posttest scores of 1.17 (18.5%; P = .02). The technical component consisted of 11 durotomy closures by 6 participants, where 4 participants performed multiple durotomies. Mean time to closure of the durotomy ranged from 490 to 546 seconds in the first and second closures, respectively (P = .66), whereby the median leak rate improved from 14 to 7 (P = .34). There were also demonstrative technical improvements by all. Simulated spinal dura mater repair appears to be a potentially valuable tool in the education of neurosurgery residents. The combination of a didactic and technical assessment appears to be synergistic in terms of educational development.
Translating G-CSF as an adjunct therapy to stem cell transplantation for stroke
dela Peña, Ike; Borlongan, Cesar V.
2015-01-01
Among recently investigated stroke therapies, stem cell treatment holds great promise by virtue of their putative ability to replace lost cells, promote endogenous neurogenesis and produce behavioral and functional improvement through their “bystander effects.” Translating stem cell in the clinic, however, presents a number of technical difficulties. A strategy suggested to enhance therapeutic utility of stem cells is combination therapy, i.e., cotransplantation of stem cells or adjunct treatment with pharmacological agents and substrates, which is assumed to produce more profound therapeutic benefits by circumventing limitations of individual treatments, and facilitating complementary brain repair processes. We previously demonstrated enhanced functional effects of co-treatment with granulocyte-colony stimulating factor (G-CSF) and human umbilical cord blood cell (hUCB) transplantation in animal models of traumatic brain injury (TBI). Here, we suggest that the aforementioned combination therapy may also produce synergistic effects in stroke. Accordingly, G-CSF treatment may reduce expression of pro-inflammatory cytokines and enhance neurogenesis rendering a receptive microenvironment for hUCB engraftment. Adjunct treatment of G-CSF with hUCB may facilitate stemness maintenance and guide neural lineage commitment of hUCB cells. Moreover, regenerative mechanisms afforded by G-CSF-mobilized endogenous stem cells, secretion of growth factors by hUCB grafts and G-CSF-recruited endothelial progenitor cells (EPCs) , as well as the potential graft–host integration that may promote synaptic circuitry re-establishment could altogether produce more pronounced functional improvement in stroked rats subjected to a combination G-CSF treatment and hUCB transplantation. Nevertheless, differences in pathology and repair processes underlying TBI and stroke deserve consideration when testing effects of combinatorial G-CSF and hUCB cell transplantation for stroke treatment. Further studies are also required to determine safety and efficacy of this intervention in both preclinical and clinical stroke studies. PMID:26482176
Resistance to drainage of cerebrospinal fluid: clinical measurement and significance1
Martins, Albert N.
1973-01-01
By infusing saline intrathecally at a constant rate until a new steady-state cerebrospinal fluid (CSF) pressure is attained, one can estimate clinically the apparent resistance (Ra) to drainage of CSF in mm saline/ml./minute. This intrathecal saline infusion test (ITSIT) was performed 36 times on 29 patients with diverse intracranial problems, and the results were analysed and, in most cases, compared with the pneumoencephalogram and the isotope cisternogram. The ITSIT is a safe, simple test to estimate Ra, but factors which are difficult to control (occult leaks from the subarachnoid space; independent fluctuations of CSF pressure) limit its reliability and clinical usefulness. If closely correlated with the clinical syndrome, the pneumoencephalogram, and the isotope cisternogram, an ITSIT may identify decisively the patient who needs a shunt. In addition the ITSIT offers another method by which to investigate the pathophysiological mechanisms of the various states of intracranial hypertension. Results from the test performed on four patients with intracranial hypertension of unknown cause (pseudotumor cerebri) suggest that the underlying mechanism in this condition is probably an impediment to normal CSF drainage. PMID:4541080
Schönberger, Jan; Möhlenbruch, Markus; Seitz, Angelika; Bußmann, Cornelia; Bächli, Heidi; Kölker, Stefan
2017-07-01
Spontaneous intracranial hypotension is a rarely diagnosed cause of headache, especially in children and adolescents. It is due to cerebrospinal fluid (CSF) leakage via spinal fistulae occurring without major trauma. An adolescent patient presented with a 3-month history of strictly postural headache. Cranial magnetic resonance imaging (MRI) showed pronounced Chiari-like prolapse of the cerebellar tonsils, narrow ventricles and enlarged cerebral veins. On spinal MRI, myelographic sequences revealed a large collection of CSF around the first sacral roots. CT myelography proved extensive spinal CSF leakage. Hence, we applied epidural patches at multiple levels. Afterwards, symptoms and radiologic findings, including Chiari-like displacement, completely resolved. A Chiari-like descent of the cerebellar tonsils alone does not secure the diagnosis of a Chiari I malformation. Especially if other findings indicate spinal CSF leakage, a systematic work-up should be initiated. In most cases, interventional techniques seal the leak successfully, resulting in a favorable outcome. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Paravalvular Leak in Structural Heart Disease.
Goel, Kashish; Eleid, Mackram F
2018-03-06
This review will summarize the growing importance of diagnosing and managing paravalvular leak associated with surgical and transcatheter valves. The burden of paravalvular leak is increasing; however, advanced imaging techniques and high degree of clinical suspicion are required for diagnosis and management. The latest data from pivotal clinical trials in the field of transcatheter aortic valve replacement suggest that any paravalvular leak greater than mild was associated with worse clinical outcomes. Percutaneous techniques for paravalvular leak closure are now the preferred approach, and surgical repair is reserved for contraindications and unsuccessful procedures. Recent data from studies evaluating paravalvular leak closure outcomes report a greater than 90% success rate with a significant improvement in patient symptoms. Paravalvular leak is a growing problem in the structural heart disease arena. Percutaneous closure is successful in more than 90% of the procedures with a low complication rate.
Postoperative ascitic leaks: the ongoing challenge.
Rosemurgy, A S; Statman, R C; Murphy, C G; Albrink, M H; McAllister, E W
1992-06-01
The leak of ascitic fluid from surgical incisions is thought to be associated with a very high mortality rate. There have been few reports, however, focusing on the clinical characteristics, management, or mortality rates of this condition. During a 10-year period, 18 patients with postoperative ascitic fluid leaks were treated. All patients had ascites before surgery and all had liver disease; in 13 of the 18 patients alcoholic liver disease was the cause of ascites. Ten of the 18 patients died (56%). Midline incisions were more often associated with recalcitrant leaks and fatal complications than were transverse incisions. Early consideration of fascial dehiscence and prompt repair is emphasized. The most effective predictor of survival was cessation of the leak.
Contamination control concepts for space station customer servicing
NASA Technical Reports Server (NTRS)
Maruya, K. A.; Ryan, L. E.; Rosales, L. A.; Medler, E. H.
1986-01-01
The customer servicing operations envisioned for the space station, which include instrument repair, orbital replacement unit (ORU) changeout, and fluid replenishment for free-flying and attached payloads, are expected to create requirements for a unique contamination control subsystem for the customer servicing facility (CSF). Both the core space station and the CSF users present unique requirements/sensitivities, not all of which are currently defined with common criteria. Preliminary results from an assessment of the effects of the CSF-induced contamination environment are reported. Strategies for a comprehensive contamination control approach and a description of specific hardware devices and their applicability are discussed.
40 CFR 60.482-9 - Standards: Delay of repair.
Code of Federal Regulations, 2010 CFR
2010-07-01
... destroyed or recovered in a control device complying with § 60.482-10. (d) Delay of repair for pumps will be... allowed for a leaking pump or valve that remains in service, the pump or valve may be considered to be...
40 CFR 60.482-9 - Standards: Delay of repair.
Code of Federal Regulations, 2012 CFR
2012-07-01
... destroyed or recovered in a control device complying with § 60.482-10. (d) Delay of repair for pumps will be... allowed for a leaking pump or valve that remains in service, the pump or valve may be considered to be...
40 CFR 60.482-9 - Standards: Delay of repair.
Code of Federal Regulations, 2011 CFR
2011-07-01
... destroyed or recovered in a control device complying with § 60.482-10. (d) Delay of repair for pumps will be... allowed for a leaking pump or valve that remains in service, the pump or valve may be considered to be...
40 CFR 85.2232 - Calibrations, adjustments-EPA 81.
Code of Federal Regulations, 2012 CFR
2012-07-01
... readings using the span gas through the probe and through the calibration port shall be made and compared... through the probe. This paragraph does not prevent those who wish to always adjust the analyzer to the... without a calibration port, perform a simple leak check (e.g., cap the probe). Repair any leaks before...
40 CFR 85.2232 - Calibrations, adjustments-EPA 81.
Code of Federal Regulations, 2011 CFR
2011-07-01
... readings using the span gas through the probe and through the calibration port shall be made and compared... through the probe. This paragraph does not prevent those who wish to always adjust the analyzer to the... without a calibration port, perform a simple leak check (e.g., cap the probe). Repair any leaks before...
40 CFR 85.2232 - Calibrations, adjustments-EPA 81.
Code of Federal Regulations, 2013 CFR
2013-07-01
... readings using the span gas through the probe and through the calibration port shall be made and compared... through the probe. This paragraph does not prevent those who wish to always adjust the analyzer to the... without a calibration port, perform a simple leak check (e.g., cap the probe). Repair any leaks before...
Optical and thermal imaging devices are remote sensing systems that can be used to detect leaking gas compounds such as methane and benzene. Use of these systems can reduce fugitive emission losses through early detection and repair at industrial facilities by providing an effici...
The winter gap effect in methane leak detection and repair with optical gas imaging cameras
NASA Astrophysics Data System (ADS)
Fox, T. A.; Barchyn, T.; Hugenholtz, C.
2017-12-01
Implementing effective leak detection and repair (LDAR) programs is essential for mitigating fugitive methane emissions from oil and gas operations. In Canada, newly proposed regulations will require that high-risk facilities be surveyed 3 times/yr for fugitive leaks. Like the United States, Canada promotes the use of Optical Gas Imaging cameras (OGIs) for detecting natural gas leaks during LDAR surveys. However, recent research suggests OGIs may perform poorly under adverse environmental conditions, especially in low temperatures. For regions like Canada that experience cold winters, OGIs may not be reliably used for months at a time, meaning that leaks may accumulate and emit for longer periods before being repaired. While considerable oil and gas activity occurs in high-latitude regions with cold winters, no research has explored how extended cold periods impact OGI-focused LDAR programs. To improve this understanding, we present a simple model exploring relationships among winter gap length, fugitive methane emissions, and investment input for LDAR programs employing OGI instruments in gas producing regions of different latitudes. Preliminary results suggest that longer gaps between LDAR surveys caused by cold temperatures result in either 1) higher total emissions for the year, or 2) greater time and equipment investment in LDAR programs to achieve emissions mitigation equivalent to LDAR programs operating under ideal conditions. When weather constraints are removed and LDAR surveys are evenly spaced throughout the year, emissions mitigation is optimized. However, as the winter gap duration and the size of the implicated area increases, fugitive leaks last longer. Furthermore, a spillover effect is observed as LDAR crews become overwhelmed with the high volume of work required as temperatures increase in the spring. Our model adds weight to the argument that LDAR programs should be tailored to regional needs, and that regulators should be more cognisant of sensor-specific limitations as they develop LDAR protocols.
Zimmitti, Giuseppe; Vauthey, Jean-Nicolas; Shindoh, Junichi; Tzeng, Ching-Wei D.; Roses, Robert E.; Ribero, Dario; Capussotti, Lorenzo; Giuliante, Felice; Nuzzo, Gennaro; Aloia, Thomas A.
2013-01-01
Objective After hepatectomy, bile leaks remain a major cause of morbidity, cost, and disability. This study was designed to determine if a novel intraoperative Air Leak Test (ALT) would reduce the incidence of post-hepatectomy biliary complications. Study design Rates of postoperative biliary complications were compared between 103 patients who underwent ALT and 120 matched patients operated on before ALT was utilized. All study patients underwent major hepatectomy without bile duct resection at 3 high-volume hepatobiliary centers between 2008 and 2012. ALT was performed by placement of a trans-cystic cholangiogram catheter to inject air into the biliary tree while the upper abdomen was filled with saline and the distal common bile duct was manually occluded. Uncontrolled bile ducts were identified by localization of air bubbles at the transection surface and were directly repaired. Results The 2 groups were similar in diagnosis, chemotherapy use, tumor number and size, resection extent, surgery duration, and blood loss (all p>0.05). Single or multiple uncontrolled bile ducts were intraoperatively detected and repaired in 62.1% of ALT vs. 8.3% of non-ALT patients (p<0.001). This resulted in a lower rate of postoperative bile leaks in ALT (1.9%) vs. non-ALT patients (10.8%, p=0.008). Independent risk factors for postoperative bile leaks included extended hepatectomy (p=0.031), caudate resection (p=0.02), and not performing ALT (p=0.002) [odds ratio (95% Confidence Interval): 3.8 (1.3–11.8), 4.0 (1.1–14.3), and 11.8 (2.4–58.8), respectively]. Conclusion ALT is an easily reproducible test that is highly effective for intraoperative detection and repair of open bile ducts, reducing the rate of postoperative bile leaks. PMID:24246619
Zimmitti, Giuseppe; Vauthey, Jean-Nicolas; Shindoh, Junichi; Tzeng, Ching-Wei D; Roses, Robert E; Ribero, Dario; Capussotti, Lorenzo; Giuliante, Felice; Nuzzo, Gennaro; Aloia, Thomas A
2013-12-01
After hepatectomy, bile leaks remain a major cause of morbidity, cost, and disability. This study was designed to determine if a novel intraoperative air leak test (ALT) would reduce the incidence of post-hepatectomy biliary complications. Rates of postoperative biliary complications were compared among 103 patients who underwent ALT and 120 matched patients operated on before ALT was used. All study patients underwent major hepatectomy without bile duct resection at 3 high-volume hepatobiliary centers between 2008 and 2012. The ALT was performed by placement of a transcystic cholangiogram catheter to inject air into the biliary tree, the upper abdomen was filled with saline, and the distal common bile duct was manually occluded. Uncontrolled bile ducts were identified by localization of air bubbles at the transection surface and were directly repaired. The 2 groups were similar in diagnosis, chemotherapy use, tumor number and size, resection extent, surgery duration, and blood loss (all, p > 0.05). Single or multiple uncontrolled bile ducts were intraoperatively detected and repaired in 62.1% of ALT vs 8.3% of non-ALT patients (p < 0.001). This resulted in a lower rate of postoperative bile leaks in ALT (1.9%) vs non-ALT patients (10.8%; p = 0.008). Independent risk factors for postoperative bile leaks included extended hepatectomy (p = 0.031), caudate resection (p = 0.02), and not performing ALT (p = 0.002) (odds ratio = 3.8; 95% CI, 1.3-11.8; odds ratio = 4.0; 95% CI, 1.1-14.3; and odds ratio = 11.8; 95% CI, 2.4-58.8, respectively). The ALT is an easily reproducible test that is highly effective for intraoperative detection and repair of open bile ducts, reducing the rate of postoperative bile leaks. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Wang, Xuhui; Xu, Minhui; Liang, Hong; Xu, Lunshan
2011-01-01
Background Multiple basilar skull fracture and cerebrospinal leak are common complications of traumatic brain injury, which required a surgical repair. But due to the complexity of basilar skull fracture after severe trauma, preoperatively an exact radiological location is always difficult. Multi-row spiral CT and MRI are currently widely applied in the clinical diagnosis. The present study was performed to compare the accuracy of cisternography by multi-row spiral CT and MRI in the diagnosis of cerebrospinal leak. Methods A total of 23 patients with multiple basilar skull fracture after traumatic brain injury were included. The radiological and surgical data were retrospectively analyzed. 64-row CT (mm/row) scan and three-dimensional reconstruction were performed in 12 patients, while MR plain scan and cisternography were performed in another 11 patients. The location of cerebrospinal leak was diagnosed by 2 experienced physicians majoring neurological radiology. Surgery was performed in all patients. The cerebrospinal leak location was confirmed and repaired during surgery. The result was considered as accurate when cerebrospinal leak was absent after surgery. Results According to the surgical exploration, the preoperative diagnosis of the active cerebrospinal leak location was accurate in 9 out of 12 patients with CT scan. The location could not be confirmed by CT because of multiple fractures in 2 patients and the missed diagnosis occurred in 1 patient. The preoperative diagnosis was accurate in 10 out of 11 patients with MRI examination. Conclusions MRI cisternography is more advanced than multi-row CT scan in multiple basilar skull fracture. The combination of the two examinations may increase the diagnostic ratio of active cerebrospinal leak. PMID:22933941
Repair of a mal-repaired biliary injury: a case report.
Aldumour, Awad; Aseni, Paolo; Alkofahi, Mohmmad; Lamperti, Luca; Aldumour, Elias; Girotti, Paolo; De Carlis, Luciano-Gregorio
2009-05-14
Iatrogenic bile-duct injury post-laparoscopic cholecystectomy remains a major serious complication with unpredictable long-term results. We present a patient who underwent laparoscopic cholecystectomy for gallstones, in which the biliary injury was recognized intraoperatively. The surgical procedure was converted to an open one. The first surgeon repaired the injury over a T-tube without recognizing the anatomy and type of the biliary lesion, which led to an unusual biliary mal-repair. Immediately postoperatively, the abdominal drain brought a large amount of bile. A T-tube cholangiogram was performed. Despite the contrast medium leaking through the abdominal drain, the mal-repair was unrecognized. The patient was referred to our hospital for biliary leak. Ultrasound and cholangiography was repeated, which showed an unanatomical repair (right to left hepatic duct anastomosis over the T-tube), with evidence of contrast medium coming out through the abdominal drain. Eventually the patient was subjected to a definitive surgical treatment. The biliary continuity was re-established by a Roux-en-Y hepatico-jejunostomy, over transanastomotic external biliary stents. The patient is now doing well 4 years after the second surgical procedure. In reviewing the literature, we found a similar type of injury but we did not find a similar surgical mal-repair. We propose an algorithm for the treatment of early and late biliary injuries.
Repair of a mal-repaired biliary injury: A case report
Aldumour, Awad; Aseni, Paolo; Alkofahi, Mohmmad; Lamperti, Luca; Aldumour, Elias; Girotti, Paolo; Carlis, Luciano Gregorio De
2009-01-01
Iatrogenic bile-duct injury post-laparoscopic cholecystectomy remains a major serious complication with unpredictable long-term results. We present a patient who underwent laparoscopic cholecystectomy for gallstones, in which the biliary injury was recognized intraoperatively. The surgical procedure was converted to an open one. The first surgeon repaired the injury over a T-tube without recognizing the anatomy and type of the biliary lesion, which led to an unusual biliary mal-repair. Immediately postoperatively, the abdominal drain brought a large amount of bile. A T-tube cholangiogram was performed. Despite the contrast medium leaking through the abdominal drain, the mal-repair was unrecognized. The patient was referred to our hospital for biliary leak. Ultrasound and cholangiography was repeated, which showed an unanatomical repair (right to left hepatic duct anastomosis over the T-tube), with evidence of contrast medium coming out through the abdominal drain. Eventually the patient was subjected to a definitive surgical treatment. The biliary continuity was re-established by a Roux-en-Y hepatico-jejunostomy, over transanastomotic external biliary stents. The patient is now doing well 4 years after the second surgical procedure. In reviewing the literature, we found a similar type of injury but we did not find a similar surgical mal-repair. We propose an algorithm for the treatment of early and late biliary injuries. PMID:19437572
[Endonasal skull base endoscopy].
Simal-Julián, Juan Antonio; Miranda-Lloret, Pablo; Pancucci, Giovanni; Evangelista-Zamora, Rocío; Pérez-Borredá, Pedro; Sanromán-Álvarez, Pablo; Perez-de-Sanromán, Laila; Botella-Asunción, Carlos
2013-01-01
The endoscopic endonasal techniques used in skull base surgery have evolved greatly in recent years. Our study objective was to perform a qualitative systematic review of the likewise systematic reviews in published English language literature, to examine the evidence and conclusions reached in these studies comparing transcranial and endoscopic approaches in skull base surgery. We searched the references on the MEDLINE and EMBASE electronic databases selecting the systematic reviews, meta-analyses and evidence based medicine reviews on skull based pathologies published from January 2000 until January 2013. We focused on endoscopic impact and on microsurgical and endoscopic technique comparisons. Full endoscopic endonasal approaches achieved gross total removal rates of craniopharyngiomas and chordomas higher than those for transcranial approaches. In anterior skull base meningiomas, complete resections were more frequently achieved after transcranial approaches, with a trend in favour of endoscopy with respect to visual prognosis. Endoscopic endonasal approaches minimised the postoperative complications after the treatment of cerebrospinal fluid (CSF) leaks, encephaloceles, meningoceles, craniopharyngiomas and chordomas, with the exception of postoperative CSF leaks. Randomized multicenter studies are necessary to resolve the controversy over endoscopic and microsurgical approaches in skull base surgery. Copyright © 2013 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
Louwes, Thijs M; Ward, William H; Lee, Kendall H; Freedman, Brett A
2015-02-01
The vast majority of combat-related penetrating spinal injuries from gunshot wounds result in severe or complete neurological deficit. Treatment is based on neurological status, the presence of cerebrospinal fluid (CSF) fistulas, and local effects of any retained fragment(s). We present a case of a 46-year-old male who sustained a spinal gunshot injury from a 7.62-mm AK-47 round that became lodged within the subarachnoid space at T9-T10. He immediately suffered complete motor and sensory loss. By 24-48 hours post-injury, he had recovered lower extremity motor function fully but continued to have severe sensory loss (posterior cord syndrome). On post-injury day 2, he was evacuated from the combat theater and underwent a T9 laminectomy, extraction of the bullet, and dural laceration repair. At surgery, the traumatic durotomy was widened and the bullet, which was laying on the dorsal surface of the spinal cord, was removed. The dura was closed in a water-tight fashion and fibrin glue was applied. Postoperatively, the patient made a significant but incomplete neurological recovery. His stocking-pattern numbness and sub-umbilical searing dysthesia improved. The spinal canal was clear of the foreign body and he had no persistent CSF leak. Postoperative magnetic resonance imaging of the spine revealed contusion of the spinal cord at the T9 level. Early removal of an intra-canicular bullet in the setting of an incomplete spinal cord injury can lead to significant neurological recovery following even high-velocity and/or high-caliber gunshot wounds. However, this case does not speak to, and prior experience does not demonstrate, significant neurological benefit in the setting of a complete injury.
Louwes, Thijs M; Ward, William H; Lee, Kendall H
2015-01-01
The vast majority of combat-related penetrating spinal injuries from gunshot wounds result in severe or complete neurological deficit. Treatment is based on neurological status, the presence of cerebrospinal fluid (CSF) fistulas, and local effects of any retained fragment(s). We present a case of a 46-year-old male who sustained a spinal gunshot injury from a 7.62-mm AK-47 round that became lodged within the subarachnoid space at T9-T10. He immediately suffered complete motor and sensory loss. By 24-48 hours post-injury, he had recovered lower extremity motor function fully but continued to have severe sensory loss (posterior cord syndrome). On post-injury day 2, he was evacuated from the combat theater and underwent a T9 laminectomy, extraction of the bullet, and dural laceration repair. At surgery, the traumatic durotomy was widened and the bullet, which was laying on the dorsal surface of the spinal cord, was removed. The dura was closed in a water-tight fashion and fibrin glue was applied. Postoperatively, the patient made a significant but incomplete neurological recovery. His stocking-pattern numbness and sub-umbilical searing dysthesia improved. The spinal canal was clear of the foreign body and he had no persistent CSF leak. Postoperative magnetic resonance imaging of the spine revealed contusion of the spinal cord at the T9 level. Early removal of an intra-canicular bullet in the setting of an incomplete spinal cord injury can lead to significant neurological recovery following even high-velocity and/or high-caliber gunshot wounds. However, this case does not speak to, and prior experience does not demonstrate, significant neurological benefit in the setting of a complete injury. PMID:25705346
Translating G-CSF as an Adjunct Therapy to Stem Cell Transplantation for Stroke.
Peña, Ike dela; Borlongan, Cesar V
2015-12-01
Among recently investigated stroke therapies, stem cell treatment holds great promise by virtue of their putative ability to replace lost cells, promote endogenous neurogenesis,and produce behavioral and functional improvement through their "bystander effects." Translating stem cell in the clinic, however, presents a number of technical difficulties. A strategy suggested to enhance therapeutic utility of stem cells is combination therapy, i.e., co-transplantation of stem cells or adjunct treatment with pharmacological agents and substrates,which is assumed to produce more profound therapeutic benefits by circumventing limitations of individual treatments and facilitating complementary brain repair processes. We previously demonstrated enhanced functional effects of cotreatment with granulocyte-colony stimulating factor (GCSF)and human umbilical cord blood cell (hUCB) transplantation in animal models of traumatic brain injury (TBI). Here,we suggest that the aforementioned combination therapy may also produce synergistic effects in stroke. Accordingly, G-CSF treatment may reduce expression of pro-inflammatory cytokines and enhance neurogenesis rendering a receptive microenvironment for hUCB engraftment. Adjunct treatment of GCSF with hUCB may facilitate stemness maintenance and guide neural lineage commitment of hUCB cells. Moreover, regenerative mechanisms afforded by G-CSF-mobilized endogenous stem cells, secretion of growth factors by hUCB grafts and G-CSF-recruited endothelial progenitor cells(EPCs), as well as the potential graft–host integration that may promote synaptic circuitry re-establishment could altogether produce more pronounced functional improvement in stroked rats subjected to a combination G-CSF treatment and hUCB transplantation. Nevertheless, differences in pathology and repair processes underlying TBI and stroke deserve consideration when testing the effects of combinatorial G-CSF and hUCB cell transplantation for stroke treatment. Further studies are also required to determine the safety and efficacy of this intervention in both preclinical and clinical stroke studies.
A new cochlear implant electrode with a "cork"-type stopper for inner ear malformations.
Sennaroğlu, Levent; Atay, Gamze; Bajin, Münir Demir
2014-08-01
Gusher in inner ear malformations is common in patients with incomplete partition type I and type III. It is also common in less severe form as oozing in incomplete partition type II and large vestibular aqueduct. It is important to prevent cerebrospinal fluid (CSF) escape around the electrode to prevent meningitis. The custom-made device was produced by Med-El Company. It has a "cork"-like stopper instead of the usual silicon ring to prevent gusher. There are two types of electrodes of different lengths. The standard one is 25mm (contact space 1.7mm) and the short one is 20mm (contact space 1.3mm). It was used in 50 patients with different inner ear malformations. Thirteen patients had gusher, and 11 patients oozing during cochleostomy. One patient with initial prototype of the cork electrode had to be revised because of persistent oozing around the electrode. Another patient had slow extrusion of the electrode most probably due to CSF pulsation and had to be revised. Both patients had no more CSF fistula. CSF fistula in inner ear malformations is a serious situation which may lead to recurrent meningitis. The new electrode with "cork" stopper looks promising in preventing the postoperative CSF leak around the electrode. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Scanning, standoff TDLAS leak imaging and quantification
NASA Astrophysics Data System (ADS)
Wainner, Richard T.; Aubut, Nicholas F.; Laderer, Matthew C.; Frish, Michael B.
2017-05-01
This paper reports a novel quantitative gas plume imaging tool, based on active near-infrared Backscatter Tunable Diode Laser Absorption Spectroscopy (b-TDLAS) technology, designed for upstream natural gas leak applications. The new tool integrates low-cost laser sensors with video cameras to create a highly sensitive gas plume imager that also quantifies emission rate, all in a lightweight handheld ergonomic package. It is intended to serve as a lower-cost, higherperformance, enhanced functionality replacement for traditional passive non-quantitative mid-infrared Optical Gas Imagers (OGI) which are utilized by industry to comply with natural gas infrastructure Leak Detection and Repair (LDAR) requirements. It addresses the need for reliable, robust, low-cost sensors to detect and image methane leaks, and to quantify leak emission rates, focusing on inspections of upstream oil and gas operations, such as well pads, compressors, and gas plants. It provides: 1) Colorized quantified images of path-integrated methane concentration. The images depict methane plumes (otherwise invisible to the eye) actively interrogated by the laser beam overlaid on a visible camera image of the background. The detection sensitivity exceeds passive OGI, thus simplifying the manual task of leak detection and location; and 2) Data and algorithms for using the quantitative information gathered by the active detection technique to deduce plume flux (i.e. methane emission rate). This key capability will enable operators to prioritize leak repairs and thereby minimize the value of lost product, as well as to quantify and minimize greenhouse gas emissions, using a tool that meets EPA LDAR imaging equipment requirements.
Primary repair of civilian colon injuries is safe in the damage control scenario.
Kashuk, Jeffry L; Cothren, C Clay; Moore, Ernest E; Johnson, Jeffrey L; Biffl, Walter L; Barnett, Carlton C
2009-10-01
Although the safety of primary repair/anastomosis for civilian colon injuries after standard laparotomy (SL) has been established, recent civilian and military reports have questioned the advisability of this technique in the patient requiring damage control laparotomy (DL). We hypothesized that, even in the high-risk DL group, primary repair could be safely used after patient stabilization and that the open abdomen would facilitate the safety of this procedure. All patients admitted to our level 1 trauma center with a colon injury over a 7-year period were reviewed from a prospectively collected database. Patients were categorized as having undergone either SL or DL at initial operation. Primary variables of interest were as follows: injury patterns; method of primary repair (suture repair, resection and primary anastomosis, resection and delayed anastomosis); diversion techniques (planned diversion or diversion for anastomotic dehiscence); and colon-related morbidity and mortality. High-risk status in the DL group was identified by the following physiologic variables: mean injury severity score (ISS), red blood cell (RBC) transfusions, ventilator days, and intensive care unit (ICU) duration of stay. During the study period, 309 patients had colonic wounds identified at laparotomy. Of these 309 patients, 280 (91%) underwent SL, of which 277 (98.9%) had primary colonic repair/anastomosis. In the SL group, 1 (0.3%) patient required diversion for subsequent leak and 2 (0.6%) patients had planned diversion The remaining 29 hemodynamically unstable patients required DL. Mean +/- standard deviation indices of injury severity in this group included: ISS = 36.2 +/- 15.8, RBC = 28.7 +/- 25.4 units, ventilator days = 20.1 +/- 16.3, ICU duration of stay = 29.5 +/- 21.6 days. Of the 29 patients in the DL group, 21 (72%) had bowel continuity successfully reestablished in 2.6 +/- 2 days after initial attempts at primary suture repair or resection/anastomosis. A total of 4 (16.6%) patients in this group developed colon-related complications, 3 of whom were treated with subsequent diversion before definitive abdominal closure. One patient developed a late leak. (day 43). Another 4 (13.8%) patients had planned diversion for injuries that were considered to be high risk for leak at subsequent reexploration. There were no colon-related deaths in either group. Primary repair of colon injuries appears safe in the majority of patients after DL. Although it is associated with a higher leak rate than SL, the open abdomen affords careful inspection of abdominal contents at reexploration to identify patients who require subsequent diversion.
Stem Cell Mobilizers: Novel Therapeutics for Acute Kidney Injury.
Xu, Yue; Zeng, Song; Zhang, Qiang; Zhang, Zijian; Hu, Xiaopeng
2017-01-01
In the past decade, rapid developments in stem cell studies have occurred. Researchers have confirmed the plasticity of bone marrow stem cells and the repair and regeneration effects of bone marrow hematopoietic stem cells on solid organs. These findings have suggested the possibility of using bone marrow stem cell mobilizers to repair and regenerate injured organs. Recent studies on the effects of granulocyte colony-stimulating factor (G-CSF) and Plerixafor (AMD3100) on mouse acute kidney injury models have confirmed that the use of bone marrow stem cell mobilizers may be an effective therapeutic measure. This paper summarizes studies describing the effects of G-CSF and AMD3100 on various acute kidney injury models over the past 10 years. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Shintoku, Ryosuke; Tosaka, Masahiko; Shimizu, Tatsuya; Yoshimoto, Yuhei
2018-01-01
We experienced a case of sphenoid sinus type meningoencephalocele manifesting as severe cerebrospinal fluid (CSF) rhinorrhea. A 35-year-old man became aware of serous nasal discharge 1 year previously, which had gradually worsened. The nasal discharge was diagnosed as CSF rhinorrhea. Head computed tomography (CT) showed several small depressions in the bone of the left middle cranial fossa, and the largest depression extended through the bone to the lateral sphenoid sinus. Head magnetic resonance imaging revealed that the meningoencephalocele projected to the lateral sphenoid sinus, through this small bone defect of the middle cranial fossa. We performed a combined craniotomy and epidural approach without intradural procedures using neuronavigation. Multiple meningoencephaloceles protruded into small depressions in the middle skull base. The small protrusions not passing through the sphenoid sinus were coagulated. The largest protrusion causing the CSF leakage was identified by neuronavigation. This meningoencephalocele was cut. Both the dural and bone sides were closed with double layers to prevent CSF leakage. The CSF rhinorrhea completely stopped after the surgery. In our case, identification of the leak site was easy with neuronavigation based on bone window CT. The epidural approach also has significant advantages with double layer closure, including both the dural and bone sides. If the site of CSF leakage is outside the foramen rotundum (as with the most common type of lateral sphenoid sinus meningoencephalocele), we recommend the epidural approach using neuronavigation for surgical treatment.
Leaks in the Chicana and Chicano Educational Pipeline. Latino Policy & Issues Brief. Number 13
ERIC Educational Resources Information Center
Yosso, Tara J.; Solorzano, Daniel G.
2006-01-01
Academic institutions facilitate the flow of knowledge, skills, and students through the educational pipeline. Yet, no matter how one measures educational outcomes, Chicana/os suffer the lowest educational attainment of any major racial or ethnic group in the United States. This brief calls for the repair of the serious and persistent leaks in the…
STS-113 workers search for oxygen leak
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- In the Payload Changeout Room, Launch Pad 39A, workers raise a platform toward the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
STS-113 workers search for oxygen leak
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Workers in the Payload Changeout Room, Launch Pad 39A, ride a platform toward the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
STS-113 workers search for oxygen leak
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Workers in the Payload Changeout Room, Launch Pad 39A, are on a platform in the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
Ahmed, Sameer; VanKoevering, Kyle K; Kline, Stephanie; Green, Glenn E; Arts, H Alexander
2017-10-01
To explore the perioperative utility of three-dimensionally (3D)-printed temporal bone models of patients undergoing repair of lateral skull base defects and spontaneous cerebrospinal fluid leaks with the middle cranial fossa approach. Case series. 3D-printed temporal bone models-based on patient-specific, high-resolution computed tomographic imaging-were constructed using inexpensive polymer materials. Preoperatively, the models demonstrated the extent of temporal lobe retraction necessary to visualize the proposed defects in the lateral skull base. Also preoperatively, Silastic sheeting was arranged across the modeled tegmen, marked, and cut to cover all of the proposed defect sites. The Silastic sheeting was then sterilized and subsequently served as a precise intraoperative template for a synthetic dural replacement graft. Of note, these grafts were customized without needing to retract the temporal lobe. Five patients underwent the middle cranial fossa approach assisted by 3D-printed temporal bone models to repair tegmen defects and spontaneous cerebrospinal fluid leaks. No complications were encountered. The prefabricated dural repair grafts were easily placed and fit precisely onto the middle fossa floor without any additional modifications. All defects were covered as predicted by the 3D temporal bone models. At their postoperative visits, all five patients maintained resolution of their spontaneous cerebrospinal fluid leaks. Inexpensive 3D-printed temporal bone models of tegmen defects can serve as beneficial adjuncts during lateral skull base repair. The models provide a panoramic preoperative view of all tegmen defects and allow for custom templating of dural grafts without temporal lobe retraction. 4 Laryngoscope, 127:2347-2351, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Sikkema, Kathleen J.; Watt, Melissa H.; Masenga, Gileard G.; Mosha, Mary V.
2016-01-01
Objectives Obstetric fistula is a maternal injury that causes uncontrollable leaking of urine or stool, and most women who develop it live in poverty in low-income countries. Obstetric fistula is associated with high rates of stigma and psychological morbidity, but there is uncertainty about the impact of surgical treatment on psychological outcomes. The objective of this exploratory study was to examine changes in psychological symptoms following surgical fistula repair, discharge and reintegration home. Methods Women admitted for surgical repair of obstetric fistula were recruited from a Tanzanian hospital serving a rural catchment area. Psychological symptoms and social functioning were assessed prior to surgery. Approximately 3 months after discharge, a data collector visited the patients' homes to repeat psychosocial measures and assess self-reported incontinence. Baseline to follow-up differences were measured with paired t tests controlling for multiple comparisons. Associations between psychological outcomes and leaking were assessed with t tests and Pearson correlations. Results Participants (N = 28) had been living with fistula for an average of 11 years. Baseline psychological distress was high, and decreased significantly at follow-up. Participants who self-reported continued incontinence at follow-up endorsed significantly higher PTSD and depression symptoms than those who reported being cured, and severity of leaking was associated with psychological distress. Conclusions Fistula patients experience improvements in mental health at 3 months after discharge, but these improvements are curtailed when women experience residual leaking. Given the rate of stress incontinence following surgery, it is important to prepare fistula patients for the possibility of incomplete cure and help them develop appropriate coping strategies. PMID:27010550
40 CFR 63.1087 - What actions must I take if a leak is detected?
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) National Emission Standards for Ethylene Manufacturing Process Units: Heat Exchange Systems and Waste Operations Repair Requirements for Heat Exchange Systems § 63.1087 What actions must I take if a... within 7 calendar days of the repair or startup, whichever is later, to confirm that the heat exchange...
40 CFR 63.1087 - What actions must I take if a leak is detected?
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) National Emission Standards for Ethylene Manufacturing Process Units: Heat Exchange Systems and Waste Operations Repair Requirements for Heat Exchange Systems § 63.1087 What actions must I take if a... within 7 calendar days of the repair or startup, whichever is later, to confirm that the heat exchange...
40 CFR 63.1087 - What actions must I take if a leak is detected?
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) National Emission Standards for Ethylene Manufacturing Process Units: Heat Exchange Systems and Waste Operations Repair Requirements for Heat Exchange Systems § 63.1087 What actions must I take if a... within 7 calender days of the repair or startup, whichever is later, to confirm that the heat exchange...
40 CFR 63.1087 - What actions must I take if a leak is detected?
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) National Emission Standards for Ethylene Manufacturing Process Units: Heat Exchange Systems and Waste Operations Repair Requirements for Heat Exchange Systems § 63.1087 What actions must I take if a... within 7 calendar days of the repair or startup, whichever is later, to confirm that the heat exchange...
40 CFR 63.1087 - What actions must I take if a leak is detected?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) National Emission Standards for Ethylene Manufacturing Process Units: Heat Exchange Systems and Waste Operations Repair Requirements for Heat Exchange Systems § 63.1087 What actions must I take if a... within 7 calender days of the repair or startup, whichever is later, to confirm that the heat exchange...
First impressions about Adherus, a new dural sealant.
Zoia, Cesare; Bongetta, Daniele; Lombardi, Francesco; Custodi, Viola Marta; Pugliese, Raffaelino; Gaetani, Paolo
2015-12-18
The aim of the study is to report our first impressions about Adherus, a novel dural sealant, used in neurosurgical endoscopic transnasal procedures. We retrospectively reviewed the clinical and surgical records of the first 11 patients with intraoperative high-flow cerebrospinal fluid leak treated with the aid of Adherus at our center between February and October 2014. The healing at the level of the dural plasty was monitored and evaluated radiologically and with regular endoscopic inspections. With a median follow-up of 210 days, no postoperative CSF leak or surgical site infections were found in any of the cases. Based on our preliminary experience, this new dural sealant seems to provide an effective aid in dural plasty during endoscopic transphenoidal procedures.
Detection of Leaks in Water Distribution System using Non-Destructive Techniques
NASA Astrophysics Data System (ADS)
Aslam, H.; Kaur, M.; Sasi, S.; Mortula, Md M.; Yehia, S.; Ali, T.
2018-05-01
Water is scarce and needs to be conserved. A considerable amount of water which flows in the water distribution systems was found to be lost due to pipe leaks. Consequently, innovations in methods of pipe leakage detections for early recognition and repair of these leaks is vital to ensure minimum wastage of water in distribution systems. A major component of detection of pipe leaks is the ability to accurately locate the leak location in pipes through minimum invasion. Therefore, this paper studies the leak detection abilities of the three NDT’s: Ground Penetration Radar (GPR) and spectrometer and aims at determining whether these instruments are effective in identifying the leak. An experimental setup was constructed to simulate the underground conditions of water distribution systems. After analysing the experimental data, it was concluded that both the GPR and the spectrometer were effective in detecting leaks in the pipes. However, the results obtained from the spectrometer were not very differentiating in terms of observing the leaks in comparison to the results obtained from the GPR. In addition to this, it was concluded that both instruments could not be used if the water from the leaks had reached on the surface, resulting in surface ponding.
Lai, Yi-Chen; Chia, Yuan-Yi; Lien, Wei-Hung
2017-03-01
Intracranial hypotension syndrome (IHS) is generally caused by cerebrospinal fluid (CSF) leakage. Complications include bilateral subdural hygroma or haematoma and herniation of the cerebellar tonsils. Epidural blood patch (EBP) therapy is indicated if conservative treatment is ineffective. We reported the case of a 46-year-old man with a history of postural headache and dizziness. The patient was treated with bed rest and daily hydration with 2000 mL of fluid for 2 weeks. However, dizziness and headache did not resolve, and he became drowsy and disoriented with incomprehensible speech. Magnetic resonance imaging demonstrated diffuse dural enhancement on the postcontrast study, sagging of the midbrain, and CSF leakage over right lateral posterior thecal sac at C2 level. We performed EBP at the level of T10-T11. We injected 14 mL of autologous blood slowly in the Trendelenburg position. Within 30 minutes, he became alert and oriented to people, place, and time. We chose thoracic EBP as first line treatment in consideration of the risk of cervical EBP such as spinal cord and nerve root compression or puncture, chemical meningitis. Also we put our patient in Trendelenburg position to make blood travel towards the site of the leak. Untreated IHS may delay the course of resolution and affect the patient's consciousness. Delivery of EBP via an epidural catheter inserted from the thoracic spine is familiar with most of anesthesiologists. It can be a safe and effective treatment for patients with IHS caused by CSF leak even at C2.Key words: Anaesthetic techniques, regional, thoracic; cerebrospinal fluid leakage; epidural blood patch; heavily T2-weighted magnetic resonance myelography; intracranial hypotension syndrome; Trendelenburg position.
Tsai, Yi-Hsin; Chen, Hung-Chieh; Tung, Hsin; Wu, Yi-Ying; Chen, Hsian-Min; Pan, Kuan-Jung; Cheng, Da-Chuan; Chen, Jeon-Hor; Chen, Clayton Chi-Chang; Chai, Jyh-Wen; Shen, Wu-Chung
2018-02-13
Spontaneous intracranial hypotension (SIH) is often misdiagnosed, and can lead to severe complications. Conventional MR sequences show a limited ability to aid in this diagnosis. MR-based intracranial pressure (MR-ICP) may be able to detect changes of intracranial elastance and pressure. To determine whether MR-ICP is able to differentiate SIH patients from normal subjects, improve diagnostic sensitivity, and provide an insight into the pathophysiology. Prospective. Twenty-eight SIH cases with orthostatic headache and 20 healthy volunteers. Cine phase-contrast MRI on a 1.5T scanner. Intracranial elastance (IE) was derived from the ratio of the peak-to-peak cerebrospinal fluid (CSF) pressure gradient (PG csf-pp ) and intracranial volume change, obtained by summing all flows before each sequential cardiac frame. Student's t-test was used to compare the MR-ICP indexes and flow parameters between SIH patients and healthy volunteers (P < 0.01). The SIH patients with cervical epidural venous dilatation (EVD) had an IE of 0.121 ± 0.027 mmHg/cm/ml, significantly higher than that of the normal volunteers (0.085 ± 0.027 mmHg/cm/ml; P = 0.002). In contradistinction, the EVD-negative SIH patients, including four with no sign of CSF leaks, had significantly lower IE (0.055 ± 0.012 mmHg/cm/ml) compared with the normal volunteers and the EVD-positive group (P = 0.001, P < 0.001). The EVD-negative patients had significantly lower PG csf-pp (0.024 ± 0.007 mmHg/cm) compared with the normal volunteers and the EVD-positive group (0.035 ± 0.011 mmHg/cm, 0.040 ± 0.010 mmHg/cm; P = 0.003, P < 0.001). Additionally, the MRI flow study showed a significant decrease in transcranial inflow and outflow of SIH patients (P < 0.01). We found that the MR-ICP method is potentially more sensitive than morphological MRI in the early diagnosis of SIH. Also, contrary to common belief, our results suggest that an abnormal craniospinal elastance might be the cause of SIH, instead of CSF leak. 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
ERIC Educational Resources Information Center
Fitzemeyer, Ted
2000-01-01
Explains how routine maintenance can help schools and universities avoid plumbing disasters. Common trouble spots and preventive techniques are discussed, as are tips for making repairs without disrupting school activities. (GR)
Section 608 Rule Presentation Slides
This document presents slides informing the public about updates to the Section 608 concerning appliance disposal, refrigerant reclamation, technician certification, refrigerant sales restriction, recordkeeping, and repairing refrigerant leaks.
Wilson, Sarah M; Sikkema, Kathleen J; Watt, Melissa H; Masenga, Gileard G; Mosha, Mary V
2016-05-01
Objectives Obstetric fistula is a maternal injury that causes uncontrollable leaking of urine or stool, and most women who develop it live in poverty in low-income countries. Obstetric fistula is associated with high rates of stigma and psychological morbidity, but there is uncertainty about the impact of surgical treatment on psychological outcomes. The objective of this exploratory study was to examine changes in psychological symptoms following surgical fistula repair, discharge and reintegration home. Methods Women admitted for surgical repair of obstetric fistula were recruited from a Tanzanian hospital serving a rural catchment area. Psychological symptoms and social functioning were assessed prior to surgery. Approximately 3 months after discharge, a data collector visited the patients' homes to repeat psychosocial measures and assess self-reported incontinence. Baseline to follow-up differences were measured with paired t tests controlling for multiple comparisons. Associations between psychological outcomes and leaking were assessed with t tests and Pearson correlations. Results Participants (N = 28) had been living with fistula for an average of 11 years. Baseline psychological distress was high, and decreased significantly at follow-up. Participants who self-reported continued incontinence at follow-up endorsed significantly higher PTSD and depression symptoms than those who reported being cured, and severity of leaking was associated with psychological distress. Conclusions Fistula patients experience improvements in mental health at 3 months after discharge, but these improvements are curtailed when women experience residual leaking. Given the rate of stress incontinence following surgery, it is important to prepare fistula patients for the possibility of incomplete cure and help them develop appropriate coping strategies.
2015-02-01
seizures, hydrocephalus, cerebral spinal fluid (CSF) leaks, infections inside the skull, vascular injuries, and cranial nerve injuries. 9-11 The...bacterial infection ). Neurosurgical procedures were based on ICD-9-CM procedure codes used to describe interventions related to severe TBI. 21 The...study of critical care trauma patients, traumatic shock was the only admission characteristic associated with infection , and infection developed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cozzi, Guido, E-mail: guido.cozzi@istitutotumori.mi.it; Severini, Aldo; Civelli, Enrico
2006-06-15
Purpose. To assess the feasibility of percutaneous transhepatic biliary drainage (PTBD) for the treatment of postsurgical biliary leaks in patients with nondilated intrahepatic bile ducts, its efficacy in restoring the integrity of bile ducts, and technical procedures to reduce morbidity. Methods. Seventeen patients out of 936 undergoing PTBD over a 20-year period had a noncholestatic liver and were retrospectively reviewed. All patients underwent surgery for cancer and suffered a postsurgical biliary leak of 345 ml/day on average; 71% were in poor condition and required permanent nutritional support. An endoscopic approach failed or was excluded due to inaccessibility of the bilemore » ducts. Results. Established biliary leaks and site of origin were diagnosed an average of 21 days (range 1-90 days) after surgery. In all cases percutaneous access to the biliary tree was achieved. An external (preleakage) drain was applied in 7 cases, 9 patients had an external-internal fistula bridging catheter, and 1 patient had a percutaneous hepatogastrostomy. Fistulas healed in an average of 31 days (range 3-118 days ) in 15 of 17 patients (88%) following PTBD. No major complications occurred after drainage. Post-PTBD cholangitis was observed in 6 of 17 patients (35%) and was related to biliary sludge formation occurring mostly when drainage lasted >30 days and was of the external-internal type. Median patient survival was 17.7 months and in all cases the repaired biliary leaks remained healed. Conclusions. PTBD is a feasible, effective, and safe procedure for the treatment of postsurgical biliary leaks. It is therefore a reliable alternative to surgical repair, which entails longer hospitalization and higher costs.« less
Reyes, Camilo; Mason, Eric; Solares, C. Arturo
2014-01-01
Introduction A substantial body of literature has been devoted to the distinct characteristics and surgical options to repair the skull base. However, the skull base is an anatomically challenging location that requires a three-dimensional reconstruction approach. Furthermore, advances in endoscopic skull base surgery encompass a wide range of surgical pathology, from benign tumors to sinonasal cancer. This has resulted in the creation of wide defects that yield a new challenge in skull base reconstruction. Progress in technology and imaging has made this approach an internationally accepted method to repair these defects. Objectives Discuss historical developments and flaps available for skull base reconstruction. Data Synthesis Free grafts in skull base reconstruction are a viable option in small defects and low-flow leaks. Vascularized flaps pose a distinct advantage in large defects and high-flow leaks. When open techniques are used, free flap reconstruction techniques are often necessary to repair large entry wound defects. Conclusions Reconstruction of skull base defects requires a thorough knowledge of surgical anatomy, disease, and patient risk factors associated with high-flow cerebrospinal fluid leaks. Various reconstruction techniques are available, from free tissue grafting to vascularized flaps. Possible complications that can befall after these procedures need to be considered. Although endonasal techniques are being used with increasing frequency, open techniques are still necessary in selected cases. PMID:25992142
Eloy, Jean Anderson; Shukla, Pratik A; Choudhry, Osamah J; Singh, Rahul; Liu, James K
2012-12-01
The endoscopic endonasal transcribriform approach (EETA) is a viable alternative option for resection of selected anterior skull base (ASB) tumors. However, this technique results in the creation of large cribriform defects. Some have reported the use of a rigid substitute for ASB reconstruction to prevent postoperative frontal lobe sagging. We evaluate the degree of frontal lobe sagging using our triple-layer technique [fascia lata, acellular dermal allograft, and pedicled nasoseptal flap (PNSF)] without the use of rigid structural reconstruction for large cribriform defects. Retrospective analysis. Nine patients underwent an EETA for resection of large ASB tumors from August 2010 to November 2011. The degree of frontal lobe displacement after EETA, defined as the ASB position, was calculated based on the most inferior position of the frontal lobe relative to the nasion-sellar line defined on preoperative and postoperative imaging. A positive value signified upward displacement, and a negative value represented inferior displacement of the frontal lobe. The average cribriform defect size was 9.3 cm(2) (range, 5.0-13.8 cm(2) ). The average distance of postoperative frontal lobe displacement was 0.2 mm (range, -3.9 to 2.9 mm) without any cases of significant brain sagging. The mean follow-up period was 10.1 months (range, 4-19 months). There were no postoperative CSF leaks. Rigid structural repair may not be necessary for ASB defect repair after endoscopic endonasal resection of the cribriform plate. Our technique for multilayer cranial base reconstruction appears to be satisfactory in preventing delayed frontal lobe sagging. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
Stopa, Edward; Baird, Andrew; Sharma, Hari
2010-01-01
In traumatic brain injury (TBI), severe disruptions occur in the choroid plexus (CP)–cerebrospinal fluid (CSF) nexus that destabilize the nearby hippocampal and subventricular neurogenic regions. Following invasive and non-invasive injuries to cortex, several adverse sequelae harm the brain interior: (i) structural damage to CP epithelium that opens the blood–CSF barrier (BCSFB) to protein, (ii) altered CSF dynamics and intracranial pressure (ICP), (iii) augmentation of leukocyte traffic across CP into the CSF–brain, (iv) reduction in CSF sink action and clearance of debris from ventricles, and (v) less efficient provision of micronutritional and hormonal support for the CNS. However, gradual post-TBI restitution of the injured CP epithelium and ependyma, and CSF homeostatic mechanisms, help to restore subventricular/subgranular neurogenesis and the cognitive abilities diminished by CNS damage. Recovery from TBI is faciltated by upregulated choroidal/ependymal growth factors and neurotrophins, and their secretion into ventricular CSF. There, by an endocrine-like mechanism, CSF bulk flow convects the neuropeptides to target cells in injured cortex for aiding repair processes; and to neurogenic niches for enhancing conversion of stem cells to new neurons. In the recovery from TBI and associated ischemia, the modulating neuropeptides include FGF2, EGF, VEGF, NGF, IGF, GDNF, BDNF, and PACAP. Homeostatic correction of TBI-induced neuropathology can be accelerated or amplified by exogenously boosting the CSF concentration of these growth factors and neurotrophins. Such intraventricular supplementation via the CSF route promotes neural restoration through enhanced neurogenesis, angiogenesis, and neuroprotective effects. CSF translational research presents opportunities that involve CP and ependymal manipulations to expedite recovery from TBI. PMID:20936524
Repair of an aberrant subclavian arterioesophageal fistula following esophageal stent placement
Hosn, Maen Aboul; Haddad, Fady; El-Merhi, Fadi; Safadi, Bassem; Hallal, Ali
2014-01-01
A fistula formation between the esophagus and an aberrant right subclavian artery is a rare but fatal complication that has been mostly described in the setting of prolonged nasogastric intubation and foreign body erosion. We report a case of a young morbidly obese patient who underwent sleeve gastrectomy that was complicated by a postoperative leak at the level of the gastroesophageal junction. A covered esophageal stent was placed endoscopically to treat the leak. The patient developed massive upper gastrointestinal bleeding secondary to the erosion of the stent into an aberrant retroesophageal right subclavian artery twelve days after stent placement. She was ultimately treated by endovascular stenting of the aberrant right subclavian artery followed by thoracotomy and esophageal repair over a T-tube. This case report highlights the multidisciplinary approach needed to diagnose and manage such a devastating complication. It also emphasizes the need for imaging studies prior to stent deployment to delineate the vascular anatomy and rule out the possibility of such an anomaly in view of the growing popularity of esophageal stents, especially in the setting of a leak. PMID:24976906
Management of Recurrent Delayed Neurologic Deficit After Thoracoabdominal Aortic Operation.
Boutrous, Mina L; Afifi, Rana O; Safi, Hazim J; Estrera, Anthony L
2016-01-01
Delayed neurologic deficit (DND) is a devastating adverse event after thoracoabdominal aortic aneurysm repair. Multiple adjuncts have been devised to counteract the development of DND, most notably cerebrospinal fluid (CSF) drainage. We report a case of a 63-year-old woman in whom DND developed four times during the first 10 days after her thoracoabdominal aortic operation. This necessitated lumbar drain "weaning" to allow for a slowly rising CSF pressure and preservation of lower extremity motor function. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Transfrontal and Transsphenoidal Approaches to Pediatric Craniopharyngioma: A National Perspective.
Lin, Yimo; Hansen, Daniel; Sayama, Christina M; Pan, I-Wen; Lam, Sandi
2017-01-01
This study compared transsphenoidal (TS) and transfrontal (TF) approaches to craniopharyngioma utilizing a national database. The Kids' Inpatient Database (2003, 2006, and 2009) was surveyed for patients with a diagnosis of craniopharyngioma who underwent a subset of surgical interventions to compare TS and TF surgery. Demographics, hospital variables, and complications/comorbidities were analyzed with multivariate regression. 314 admissions (TS = 104, TF = 210) were identified. The mean age was 14.8 (TS) versus 9.8 (TF) years (p < 0.001). The mean number of diagnoses was 4.6 (TS) versus 6.2 (TF) (p < 0.001). Diabetes insipidus was associated with 38% (TS) and 69% (TF). Cerebrospinal fluid (CSF) leak affected 19% TS and 4% TF resections. Other complications and comorbidities included postoperative stroke (2% TS vs. 5% TF), panhypopituitarism (5 vs. 8%), death (0 vs. 1%), cranial nerve deficits (1 vs. 6%), thrombotic events (7 vs. 17%), and seizures (0 vs. 12%). 98% of patients were discharged home after a mean 6-day length of stay (LOS) after TS, whereas 90% of TF patients had a LOS of 12 days. TS cases were more likely to be privately insured (68%) and from higher income brackets (61%) than TF ones (56 and 2%, respectively) (p < 0.05). In multivariate regression models adjusting for age, sex, race, number of diagnoses, surgical approach, hospital volume, and insurance type, the TS approach was associated with an increased incidence of CSF leak (OR 10, p < 0.001). More documented diagnoses (OR 16-60, p < 0.01) and TF approach (OR 2.6, p < 0.01) were associated with an increased incidence of other complications and comorbidities. Age younger than 10 (β-coefficient 2.3, p = 0.01), more diagnoses (β-coefficient 1.2, p < 0.001), and TF approach (β- coefficient 3.0, p < 0.01) were associated with increased LOS. A higher number of diagnoses were associated with nonhome discharge destinations (β-coefficient 1.29, p < 0.001). TS surgery was associated with an increased incidence of CSF leak but shorter LOS; TF surgery was associated with an increased incidence of other complications. Patients undergoing TS surgery were more likely to have private insurance and a higher family income bracket. © 2017 S. Karger AG, Basel.
Nasoseptal flap necrosis: a rare complication of endoscopic endonasal surgery.
Chabot, Joseph D; Patel, Chirag R; Hughes, Marion A; Wang, Eric W; Snyderman, Carl H; Gardner, Paul A; Fernandez-Miranda, Juan C
2018-05-01
OBJECTIVE The vascularized nasoseptal flap (NSF) has become the workhorse for skull base reconstruction during endoscopic endonasal surgery (EES) of the ventral skull base. Although infrequently reported, as with any vascularized flap the NSF may undergo ischemic necrosis and become a nidus for infection. The University of Pittsburgh Medical Center's experience with NSF was reviewed to determine the incidence of necrotic NSF in patients following EES and describe the clinical presentation, imaging characteristics, and risk factors associated with this complication. METHODS The electronic medical records of 1285 consecutive patients who underwent EES at the University of Pittsburgh Medical Center between January 2010 and December 2014 were retrospectively reviewed. From this first group, a list of all patients in whom NSF was used for reconstruction was generated and further refined to determine if the patient returned to the operating room and the cause of this reexploration. Patients were included in the final analysis if they underwent endoscopic reexploration for suspected CSF leak or meningitis. Those patients who returned to the operating room for staged surgery or hematoma were excluded. Two neurosurgeons and a neuroradiologist, who were blinded to each other's results, assessed the MRI characteristics of the included patients. RESULTS In total, 601 patients underwent NSF reconstruction during the study period, and 49 patients met the criteria for inclusion in the final analysis. On endoscopic exploration, 8 patients had a necrotic, nonviable NSF, while 41 patients had a viable NSF with a CSF leak. The group of patients with a necrotic, nonviable NSF was then compared with the group with viable NSF. All 8 patients with a necrotic NSF had clinical and laboratory evidence indicative of meningitis compared with 9 of 41 patients with a viable NSF (p < 0.001). Four patients with necrotic flaps developed epidural empyema compared with 2 of 41 patients in the viable NSF group (p = 0.02). The lack of NSF enhancement on MR (p < 0.001), prior surgery (p = 0.043), and the use of a fat graft (p = 0.004) were associated with necrotic NSF. CONCLUSIONS The signs of meningitis after EES in the absence of a clear CSF leak with the lack of NSF enhancement on MRI should raise the suspicion of necrotic NSF. These patients should undergo prompt exploration and debridement of nonviable tissue with revision of skull base reconstruction.
Katasani, V G; Leeth, R R; Tishler, D S; Leath, T D; Roy, B P; Canon, C L; Vickers, S M; Clements, R H
2005-11-01
Anastomotic leak after laparoscopic Roux-en-Y gastric bypass (LGB) is a major complication that must be recognized and treated early for best results. There is controversy in the literature regarding the reliability of upper GI series (UGI) in diagnosing leaks. LGB was performed in patients meeting NIH criteria for the surgical treatment of morbid obesity. All leaks identified at the time of surgery were repaired with suture and retested. Drains were placed at the surgeon's discretion. Postoperatively, UGI was performed by an experienced radiologist if there was a clinical suspicion of leak. From September 2001 until October 2004, a total of 553 patients (age 40.4 +/- 9.2 years, BMI 48.6 +/- 7.2) underwent LGB at UAB. Seventy-eight per cent (431 of 553) of patients had no clinical evidence suggesting anastomotic leak and were managed expectantly. Twenty-two per cent (122 of 553) of patients met at least one inclusion criteria for leak and underwent UGI. Four of 122 patients (3.2%) had a leak, two from anastomosis and two from the perforation of the stapled end of the Roux limb. No patient returned to the operating room without a positive UGI. High clinical suspicion and selectively performed UGI based on clinical evidence is reliable in detecting leaks.
Lal, Dave R; Gadepalli, Samir K; Downard, Cynthia D; Ostlie, Daniel J; Minneci, Peter C; Swedler, Ruth M; Chelius, Thomas H; Cassidy, Laura; Rapp, Cooper T; Billmire, Deborah; Bruch, Steven; Burns, R Carland; Deans, Katherine J; Fallat, Mary E; Fraser, Jason D; Grabowski, Julia; Hebel, Ferdynand; Helmrath, Michael A; Hirschl, Ronald B; Kabre, Rashmi; Kohler, Jonathan; Landman, Matthew P; Leys, Charles M; Mak, Grace Z; Raque, Jessica; Rymeski, Beth; Saito, Jacqueline M; St Peter, Shawn D; von Allmen, Daniel; Warner, Brad W; Sato, Thomas T
2017-06-01
Perioperative management of infants with esophageal atresia and tracheoesophageal fistula (EA/TEF) is frequently based on surgeon experience and dogma rather than evidence-based guidelines. This study examines whether commonly perceived important aspects of practice affect outcome in a contemporary multi-institutional cohort of patients undergoing primary repair for the most common type of esophageal atresia anomaly, proximal EA with distal TEF. The Midwest Pediatric Surgery Consortium conducted a multicenter, retrospective study examining selected outcomes on infants diagnosed with proximal EA with distal TEF who underwent primary repair over a 5-year period (2009-2014), with a minimum 1-year follow up, across 11 centers. 292 patients with proximal EA and distal TEF who underwent primary repair were reviewed. The overall mortality was 6% and was significantly associated with the presence of congenital heart disease (OR 4.82, p=0.005). Postoperative complications occurred in 181 (62%) infants, including: anastomotic stricture requiring intervention (n=127; 43%); anastomotic leak (n=54; 18%); recurrent fistula (n=15; 5%); vocal cord paralysis/paresis (n=14; 5%); and esophageal dehiscence (n=5; 2%). Placement of a transanastomotic tube was associated with an increase in esophageal stricture formation (OR 2.2, p=0.01). Acid suppression was not associated with altered rates of stricture, leak or pneumonia (all p>0.1). Placement of interposing prosthetic material between the esophageal and tracheal suture lines was associated with an increased leak rate (OR 4.7, p<0.001), but no difference in the incidence of recurrent fistula (p=0.3). Empiric postoperative antibiotics for >24h were used in 193 patients (66%) with no difference in rates of infection, shock or death when compared to antibiotic use ≤24h (all p>0.3). Hospital volume was not associated with postoperative complication rates (p>0.08). Routine postoperative esophagram obtained on day 5 resulted in no delayed/missed anastomotic leaks or a difference in anastomotic leak rate as compared to esophagrams obtained on day 7. Morbidity after primary repair of proximal EA and distal TEF patients is substantial, and many common practices do not appear to reduce complications. Specifically, this large retrospective series does not support the use of prophylactic antibiotics beyond 24h and empiric acid suppression may not prevent complications. Use of a transanastomotic tube was associated with higher rates of stricture, and interposition of prosthetic material was associated with higher leak rates. Routine postoperative esophagram can be safely obtained on day 5 resulting in earlier initiation of oral feeds. Treatment study. III. Copyright © 2017 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-07-01
... depletion of stocked parts, there must be documentation that the spare parts were sufficiently stocked on-site before depletion and the reason for depletion. (5) Dates of process unit or affected facility...
ERIC Educational Resources Information Center
Kennedy, Mike
2001-01-01
Explains how schools that focus on roofing maintenance are more likely to avoid leaks and costly repairs. Brief comments on the U.S. Department of Education's report on roof ratings and adequacy are highlighted. (GR)
Sugawara, Taku; Itoh, Yasunobu; Hirano, Yoshitaka; Higashiyama, Naoki; Shimada, Yoichi; Kinouchi, Hiroyuki; Mizoi, Kazuo
2005-10-01
Extradural or subcutaneous cerebrospinal fluid (CSF) leakage is a common complication after spinal surgery and is associated with the risks of poor wound healing, meningitis, and pseudomeningocele. Numerous methods to prevent postoperative CSF leakage are available, but pressure-tight dural closure remains difficult, especially with synthetic surgical membranes. The efficacy of a novel dural closure technique was assessed by detecting extradural or subcutaneous CSF leakage on magnetic resonance imaging. The novel dural closure technique using absorbable polyglactin acid sheet and fibrin glue and the conventional procedure using only fibrin glue were evaluated retrospectively by identifying extradural or subcutaneous CSF leakage on magnetic resonance imaging scans in the acute (2-7 d) and chronic (3-6 mo) postoperative stages after spinal intradural surgery in 53 patients. The incidence of extradural and subcutaneous CSF leakage was significantly lower (P < 0.05) in the acute (20%) and chronic (0%) stages using polyglactin acid sheet and fibrin glue in 15 patients compared with that in the acute (81%) and chronic (24%) stages using only fibrin glue in 38 patients. One patient in the fibrin glue-only group required repair surgery for cutaneous CSF leakage. The combination of polyglactin acid sheet and fibrin glue can achieve water-tight closure after spinal intradural surgery and can minimize the risk of intractable postoperative CSF leakage. This simple, economical technique is recommended for dural closure after spinal intradural surgery.
Nagashima, Hiroaki; Mizukawa, Katsu; Taniguchi, Masaaki; Yamamoto, Yusuke; Kohmura, Eiji
Gorham's syndrome is a rare bone disorder characterized by massive osteolysis of unknown etiology. There are no reports of comorbidity involving cerebrospinal fluid (CSF) leakage and Chiari I malformation with Gorham's syndrome. Here, we report an unusual case of an acute presyrinx state complicated by bacterial meningitis due to CSF leakage and Chiari I malformation associated with Gorham's disease of the skull base. A 25-year-old woman with Chiari I malformation associated with Gorham's syndrome presented with aggressive paresthesia following bacterial meningitis. Axial magnetic resonance imaging (MRI) and computed tomography (CT) cisternography revealed CSF leakage in the right petrous apex. A presyrinx state was diagnosed based on the clinical symptoms and MRI findings. With resolution of the bacterial meningitis, the spinal edema and tonsillar ectopia also improved. Surgical repair of the CSF leakage was performed by an endoscopic endonasal transsphenoidal approach to prevent recurrence of meningitis. The postoperative course was uneventful. Skull base osteolysis in Gorham's syndrome may induce Chiari I malformation and CSF leakage. We should pay attention to acute progression of clinical symptoms because Gorham's syndrome may predispose to development of Chiari I malformation and may be complicated by CSF leakage. Copyright © 2017 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
24 CFR 1003.202 - Eligible rehabilitation and preservation activities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the efficient use of water through such means as water saving faucets and shower heads and repair of water leaks; (6) Connection of residential structures to water distribution lines or local sewer...
49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability of...
49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability of...
49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability of...
49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-23
... trigger rates for comfort cooling, commercial refrigeration, and industrial process refrigeration and air..., commercial refrigeration, and industrial process refrigeration appliances. This action also proposes to...
Sharma, Rajeev; Singh, Bhoopendra; Kedia, Shweta; Laythalling, Rajinder Kumar
2017-02-01
Meningocele is defined as a protrusion of the meninges through an opening in the skull or spinal column, forming a bulge or sac filled with cerebrospinal fluid. A pseudomeningocele is defined as a cerebrospinal fluid (CSF) collection formed due to escape of CSF through a dural defect with trapping of CSF into the surrounding soft tissues. We herby report rare occurrence of a large (pseudo)meningocele in a young patient with congenital skull base defect presenting as upper lateral neck swelling. We present the case of a 17-year-old boy who had painless progressive swelling right side of the upper neck without any history of meningitis or CSF leak. He had a history of undergoing cranioplasty using steel plates for nontraumatic boggy swelling right parieto-occipital region at the age of 5 years at another hospital. Clinical examination showed painless swelling right side of the upper neck, with positive cough impulse and transillumination. CT head with cisternography showed a large right skull base defect through which a large pseudomeningocele was herniating, thus producing upper neck swelling and compressing oral cavity. The neck swelling and intraoral bulge reduced in size after the coperitoneal shunt. Differential diagnosis of (pseudo)meningocele should be considered while evaluating a painless progressive upper neck swelling having cough impulse and transillumination in a young patient.
Nishihara, Takashi; Hayama, Manabu; Okamoto, Norio; Tanaka, Ayako; Nishida, Takuji; Shiroyama, Takayuki; Tamiya, Motohiro; Morishita, Naoko; Suzuki, Hidekazu; Matsuoka, Hiroto; Hirashima, Tomonori
2016-01-01
A prolonged air leak caused by pulmonary tuberculosis is difficult to treat, and little is known about optimal treatment strategies. We herein report the case of a 60-year-old man who demonstrated tuberculous empyema with a fistula. An air leak from a tuberculous cavity in his left upper lobe persisted for approximately 4 months; surgical repair could not be performed due to a poor physical status and undernourishment. However, the air leak was successfully treated with endobronchial occlusion using two silicone spigots in left B3b and B4, without any adverse effects or aggravation of the infection.
Schiff, A; Roy, S; Pignot, M; Ghosh, S K; Fegelman, E J
2017-01-01
This targeted chart review study reports the first ever detailed global account of clinical approaches adopted to detect and manage anastomotic leaks identified during surgery in routine clinical practice. 156 surgeons from eight countries retrospectively extracted data from surgical records of 458 patients who underwent colorectal surgery with an identified intraoperative leak at the circular anastomosis. Demographic details, procedures, and outcomes were analyzed descriptively, by country. Most surgeries were performed laparoscopically (57.6%), followed by open surgeries (35.8%). The burden of intraoperative leaks on the healthcare system is driven in large part by the additional interventions such as using a sealant, recreating the anastomosis, and diverting the anastomosis to a colostomy bag, undertaken to manage the leak. The mean duration of hospitalization was 19.9 days. Postoperative anastomotic leaks occurred in 62 patients (13.5%), most frequently 4 to 7 days after surgery. Overall, country-specific differences were observed in patient characteristics, surgical procedures, method of diagnosis of intraoperative leak, interventions, and length of hospital stay. The potential cost of time and material needed to repair intraoperative leaks during surgery is substantial and often hidden to the healthcare system, potentially leading to an underestimation of the impact of this complication.
Pettorini, Benedetta Ludovica; Tamburrini, Gianpiero; Massimi, Luca; Paternoster, Giovanna; Caldarelli, Massimo; Di Rocco, Concezio
2010-02-01
CSF leakage is a common complication of neurosurgical procedures, with defective dural suture thought to be the most frequent cause. We report our experience with a new collagen foil (TissuDura, Baxter Healthcare SA, Switzerland) utilized as dural substitute in paediatric neurosurgical procedures. TissuDura was used in children consecutively operated on at the department of paediatric neurosurgery, Catholic University, Rome, from March 2004 to August 2007. Children underwent surgical procedures in supratentorial, infratentorial and spinal compartments. In supratentorial and spinal procedures, the dural graft was used according to the overlay technique. In the posterior fossa procedures, the underlay technique was used. Forty-seven patients received TissuDura during surgery. Thirty-one patients underwent surgery for the removal of posterior fossa tumours, nine for supratentorial tumours and seven for spinal dysraphisms. No CSF leakage was observed following the use of TissuDura in supratentorial procedures. Two post-operative CSF leaks occurred in patients who had undergone spinal surgery. No post-operative hydrocephalus was noted in these two surgery groups. Three cases of CSF leakage occurred in patients who had undergone posterior cranial fossa surgery. All 3 cases had an associated supratentorial ventricular dilation present prior to the removal of the tumour (one case) or occurring after the tumour excision (two cases). No clinically evident adverse reactions directly related to TissuDura were observed. The main advantages of TissuDura were its apparent ability to prevent CSF leakage when utilized in a specific subset of patients, and the absence of reactions or postoperative infections.
24 CFR 570.202 - Eligible rehabilitation and preservation activities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... increase the efficient use of water through such means as water savings faucets and shower heads and repair of water leaks; (6) Connection of residential structures to water distribution lines or local sewer...
76 FR 39899 - Notice of Lodging of Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-07
... emissions of nitrogen oxides, sulfur dioxide, volatile organic compounds, and benzene. Among other things... refinery's benzene monitoring program is enhanced, and the refinery's leak-detection-and-repair (LDAR...
Egea, Laia; McAllister, Christopher S.; Lakhdari, Omar; Minev, Ivelina; Shenouda, Steve; Kagnoff, Martin F.
2012-01-01
GM-CSF is a growth factor that promotes the survival and activation of macrophages and granulocytes, and dendritic cell (DC) differentiation and survival in vitro. The mechanism by which exogenous GM-CSF ameliorates the severity of Crohn’s disease in humans and colitis in murine models has been considered mainly to reflect its activity on myeloid cells. We used GM-CSF deficient (GM-CSF−/−) mice to probe the functional role of endogenous host-produced GM-CSF in a colitis model induced after injury to the colon epithelium. Dextran sodium sulfate (DSS) at doses that resulted in little epithelial damage and mucosal ulceration in wild type (WT) mice resulted in marked colon ulceration and delayed ulcer healing in GM-CSF−/− mice. Colon crypt epithelial cell proliferation in vivo was significantly decreased in GM-CSF−/− mice at early times after DSS injury. This was paralleled by decreased expression of crypt epithelial cell genes involved in cell cycle, proliferation, and wound healing. Decreased crypt cell proliferation and delayed ulcer healing in GM-CSF−/− mice were rescued by exogenous GM-CSF, indicating the lack of a developmental abnormality in the epithelial cell proliferative response in those mice. Non-hematopoietic cells and not myeloid cells produced the GM-CSF important for colon epithelial proliferation after DSS-induced injury as revealed by bone marrow chimera and DC depletion experiments, with colon epithelial cells being the cellular source of GM-CSF. Endogenous epithelial cell produced GM-CSF has a novel non-redundant role in facilitating epithelial cell proliferation and ulcer healing in response to injury of the colon crypt epithelium. PMID:23325885
Indorewala, Shabbir; Nemade, Gaurav; Indorewala, Abuzar; Mahajan, Gauri
2018-06-23
To see effectiveness of the senior author's repair technique for repair of large (equal to or larger than 10 mm) bony lateral skull base defects. Retrospective. Secondary/tertiary care center. We performed retrospective review of 9 surgeries done in our institution between January 2010 and December 2013 for repair of large lateral bony skull base defects. We defined skull base defects extra-cranially and repaired them intra-cranially. We made an extracorporeal sandwich of autologous fascia-bone-fascia (fascia lata and nasal septal bone) and sewed it together to make it into a unit-sandwich graft. This extracorporeally sewed unit-sandwich graft was then inserted to close the large skull base defects either via (1) a cranial slit-window, or (2) the skull base defect itself. Since skull base is bony, bony repair is preferred. Bone plates that are easily available for skull base repair are calvarial and nasal septal bone. Occasionally, harvest of split calvarial bone carries risk of major complications. We preferred nasal septal bone. Harvesting of septal bone even in children using a posterior incision should not disturb the cartilage growth centers. All nine patients were operated by this technique. We had four patients with cerebrospinal fluid leak, and five patients with brain herniation. All these patients had complete reversal of herniation of cranial contents and cessation of cerebrospinal fluid leak. On imaging, in 6 cases the bone graft remained in original intended position after 12 months of surgery. The bone graft was not identifiable in 3 cases. The senior author's technique using autologous multi-layered graft is simple to master, repeatable and very effective.
Treatment of anterior skull base defects by a transnasal endoscopic approach in children.
Di Rocco, Federico; Couloigner, Vincent; Dastoli, Patricia; Sainte-Rose, Christian; Zerah, Michel; Roger, Gilles
2010-11-01
The object of this study was to assess the efficacy and complications of endoscopic management of anterior skull base defects. The authors reviewed the medical records of 28 children (20 boys and 8 girls) undergoing endoscopic repair of anterior skull base defects in their tertiary referral center between 2001 and 2008; 18 cases were congenital and 10 cases posttraumatic. During the endoscopic procedure, rigid telescopes--2.7 or 4 mm in diameter, with 0° or 30° lenses--were used. In 23 patients the anterior skull base defect was sealed with fragments of middle turbinate (bone and mucosa). In the remaining 5 patients it was sealed with cartilage harvested from the nasal septum (3 cases) or from the auricle (2 cases), fibrin glue, and oxidized cellulose. A combined external and endoscopic approach was required in 3 cases because of the size and extensions of the encephalocele. Outcome was primarily assessed by means of clinical examination, nasal fibroscopy, and imaging. The mean duration of follow-up was 26.7 months (range 9-57 months). One patient treated by a combined approach died of meningitis 2 years after surgery. In the remaining 27 patients, there was no recurrence of CSF leak, meningitis, or encephalocele. An iatrogenic frontal or ethmoidal mucocele was observed in 4 cases. The endoscopic approach is a minimally invasive, safe, and efficient technique for removing nasal encephaloceles in children.
Delgado-López, Pedro David; Garcés-Pérez, Gloria; García-Carrasco, Juan; Alonso-García, Esther; Gómez-Menéndez, Ana Isabel; Martín-Alonso, Javier
2018-06-01
Posterior reversible encephalopathy syndrome (PRES) is a clinicoradiological condition encountered in many different clinical settings, generally occurring in the context of hypertensive crisis, immunosuppressive therapy or autoimmune diseases. It is characterized by headache, stupor, seizures and visual alterations. MRI findings include white matter changes preferentially in the parieto-occipital regions. Although pathogenesis is not fully elucidated, vasoconstriction and brain hypoperfusion seem to be the cause of brain ischemia and vasogenic edema. CSF hypotension is also a reported plausible pathogenic mechanism. We present a unique case of PRES following laminectomy and fixation for L4-5 lumbar stenosis and spondylolisthesis. The patient presented with a 5-day duration status epilepticus immediately after surgery. Brain MRI showed FLAIR and T2 hyperintensities in the bilateral parietal and occipital lobes and external capsules. On the basis of her postoperative lumbar images, we hypothesize that an unnoticed CSF leak might have contributed to develop PRES in this case. The patient developed multiple postoperative complications. Following treatment for severe hypertension and seizures she ultimately recovered. Prompt recognition and treatment of this potentially life-threatening syndrome is necessary in order to increase the likelihood of favorable outcome. Spinal surgeons need to be aware of the possibility of neurological deterioration following spinal surgery and be alert about the occurrence of a dural leak, either recognized or unnoticed, as the plausible mechanism triggering PRES. Copyright © 2018 Elsevier Inc. All rights reserved.
Mapping urban pipeline leaks: methane leaks across Boston.
Phillips, Nathan G; Ackley, Robert; Crosson, Eric R; Down, Adrian; Hutyra, Lucy R; Brondfield, Max; Karr, Jonathan D; Zhao, Kaiguang; Jackson, Robert B
2013-02-01
Natural gas is the largest source of anthropogenic emissions of methane (CH(4)) in the United States. To assess pipeline emissions across a major city, we mapped CH(4) leaks across all 785 road miles in the city of Boston using a cavity-ring-down mobile CH(4) analyzer. We identified 3356 CH(4) leaks with concentrations exceeding up to 15 times the global background level. Separately, we measured δ(13)CH(4) isotopic signatures from a subset of these leaks. The δ(13)CH(4) signatures (mean = -42.8‰ ± 1.3‰ s.e.; n = 32) strongly indicate a fossil fuel source rather than a biogenic source for most of the leaks; natural gas sampled across the city had average δ(13)CH(4) values of -36.8‰ (± 0.7‰ s.e., n = 10), whereas CH(4) collected from landfill sites, wetlands, and sewer systems had δ(13)CH(4) signatures ~20‰ lighter (μ = -57.8‰, ± 1.6‰ s.e., n = 8). Repairing leaky natural gas distribution systems will reduce greenhouse gas emissions, increase consumer health and safety, and save money. Copyright © 2012 Elsevier Ltd. All rights reserved.
GM-CSF ameliorates microvascular barrier integrity via pericyte-derived Ang-1 in wound healing.
Yan, Min; Hu, Yange; Yao, Min; Bao, Shisan; Fang, Yong
2017-11-01
Skin wound healing involves complex coordinated interactions of cells, tissues, and mediators. Maintaining microvascular barrier integrity is one of the key events for endothelial homeostasis during wound healing. Vasodilation is observed after vasoconstriction, which causes blood vessels to become porous, facilitates leukocyte infiltration and aids angiogenesis at the wound-area, postinjury. Eventually, vessel integrity has to be reestablished for vascular maturation. Numerous studies have found that granulocyte macrophage colony-stimulating factor (GM-CSF) accelerates wound healing by inducing recruitment of repair cells into the injury area and releases of cytokines. However, whether GM-CSF is involving in the maintaining of microvascular barrier integrity and the underlying mechanism remain still unclear. Aim of this study was to investigate the effects of GM-CSF on modulation of microvascular permeability in wound healing and underlying mechanisms. Wound closure and microvascular leakage was investigated using a full-thickness skin wound mouse model after GM-CSF intervention. The endothelial permeability was measured by Evans blue assay in vivo and in vitro endothelium/pericyte co-culture system using a FITC-Dextran permeability assay. To identify the source of angiopoietin-1 (Ang-1), double staining is used in vivo and ELISA and qPCR are used in vitro. To determine the specific effect of Ang-1 on GM-CSF maintaining microvascular stabilization, Ang-1 siRNA was applied to inhibit Ang-1 production in vivo and in vitro. Wound closure was significantly accelerated and microvascular leakage was ameliorated after GM-CSF treatment in mouse wound sites. GM-CSF decreased endothelial permeability through tightening endothelial junctions and increased Ang-1 protein level that was derived by perictye. Furthermore, applications of siRNAAng-1 inhibited GM-CSF mediated protection of microvascular barrier integrity both in vivo and in vitro. Our data indicate that GM-CSF ameliorates microvascular barrier integrity via pericyte-derived Ang-1 during wound healing. © 2018 by the Wound Healing Society.
Cho, Ji Young; Chan, Chee Keong; Lee, Sang-Ho; Choi, Won-Chul; Maeng, Dae Hyeon; Lee, Ho-Yeon
2012-06-01
Retrospective review To determine the efficacy of management of cerebrospinal fluid (CSF) leakage after the anterior thoracic approach. CSF leakage after incidental durotomy commonly occurs after anterior thoracic ossification of posterior longitudinal ligament (OPLL) surgery. Pseudomeningocele will invariably form under such circumstances. Among them, uncontrolled CSF leakage with a fistulous condition is problematic. As a solution, we have managed these durotomies with chest drains alone without any CSF drainage by the concept of a "volume-controlled pseudomeningocele." Between 2001 and 2009, CSF leakage occurred in 26 patients (37.7%) of the total 69 patients who underwent anterior decompression for thoracic OPLL. In the initial 11 cases, subarachnoid drainage was utilized as an augmentive measure in combination with chest tube drainage in the postoperative period (group A). In the subsequent 15 cases, the durotomy was managed in a similar manner but in the absence of any subarachnoid drainage (group B). Various parameters such as the duration of postoperative hospital stay, clinical outcome score, drainage output, resolution of CSF leakage, complications, and additional surgery performed were analyzed and compared between the 2 groups. A resolution of the CSF leakage grading system was also proposed for the residual pseudomeningocele that formed in each group. There were statistically no significant differences in the outcome parameters between the 2 groups and also in patients with grade I or grade II residual pseudomeningocele of the new grading system. Two complications occurred in group A. No reexploration for persistent CSF leakage was required in both groups. CSF leakage managed with controlled chest tube drainage can produce a comparable result with those with additional subarachnoid drainage when watertight dural repair is impossible. The concept of controlled pseudomeningocele may be a useful and practical technique for the treatment of CSF leakage after anterior thoracic OPLL surgery.
Smart pipeline network : pipe and repair sensor system.
DOT National Transportation Integrated Search
2013-07-26
Leak detection within the national pipeline network has long been recognized as a much-needed : capability to reduce the loss of high value product, improve public safety, and to reduce the : emissions of environmentally damaging substances. : In rec...
40 CFR Table 2 to Subpart Mmm of... - Standards for New and Existing PAI Sources
Code of Federal Regulations, 2012 CFR
2012-07-01
... a HAP Particulate matter concentration not to exceed 0.01 gr/dscf. Heat exchange systems Each heat exchange system used to cool process equipment in PAI manufacturing operations Monitoring and leak repair...
40 CFR Table 2 to Subpart Mmm of... - Standards for New and Existing PAI Sources
Code of Federal Regulations, 2011 CFR
2011-07-01
... a HAP Particulate matter concentration not to exceed 0.01 gr/dscf. Heat exchange systems Each heat exchange system used to cool process equipment in PAI manufacturing operations Monitoring and leak repair...
77 FR 49023 - Notice of Lodging of Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-15
... the management and control of ozone-depleting substances used as refrigerants in defendants' vessels... refrigerant charge during a 12-month period. This is a stricter standard than is required by the leak repair...
The choroid plexus: function, pathology and therapeutic potential of its transplantation.
Emerich, Dwaine F; Vasconcellos, Alfred V; Elliott, Robert B; Skinner, Stephen J M; Borlongan, Cesario V
2004-08-01
The choroid plexus (CP) produces cerebrospinal fluid (CSF) and forms the blood-CSF barrier. However, the CP may have additional functions in the CNS beyond these traditional roles. Preclinical and clinical studies in ageing and neurodegeneration demonstrate anatomical and physiological changes in CP, suggesting roles in normal and pathological conditions and potentially endogenous repair processes following trauma. One of the broadest functions of the CP is establishing and maintaining the extracellular milieu throughout the brain and spinal cord, in part by secreting numerous growth factors into the CSF. The endogenous secretion of growth factors raises the possibility that transplantable CP might enable delivery of these molecules to the brain, while avoiding the conventional molecular and genetic alterations associated with modifying cells to secrete selected products. This review describes some of the anatomical and functional changes of CP in ageing and neurodegeneration, and recent demonstrations of the therapeutic potential of transplanted CP for neural trauma.
Fibronectin induces macrophage migration through a SFK-FAK/CSF-1R pathway.
Digiacomo, Graziana; Tusa, Ignazia; Bacci, Marina; Cipolleschi, Maria Grazia; Dello Sbarba, Persio; Rovida, Elisabetta
2017-07-04
Integrins, following binding to proteins of the extracellular matrix (ECM) including collagen, laminin and fibronectin (FN), are able to transduce molecular signals inside the cells and to regulate several biological functions such as migration, proliferation and differentiation. Besides activation of adaptor molecules and kinases, integrins transactivate Receptor Tyrosine Kinases (RTK). In particular, adhesion to the ECM may promote RTK activation in the absence of growth factors. The Colony-Stimulating Factor-1 Receptor (CSF-1R) is a RTK that supports the survival, proliferation, and motility of monocytes/macrophages, which are essential components of innate immunity and cancer development. Macrophage interaction with FN is recognized as an important aspect of host defense and wound repair. The aim of the present study was to investigate on a possible cross-talk between FN-elicited signals and CSF-1R in macrophages. FN induced migration in BAC1.2F5 and J774 murine macrophage cell lines and in human primary macrophages. Adhesion to FN determined phosphorylation of the Focal Adhesion Kinase (FAK) and Src Family Kinases (SFK) and activation of the SFK/FAK complex, as witnessed by paxillin phosphorylation. SFK activity was necessary for FAK activation and macrophage migration. Moreover, FN-induced migration was dependent on FAK in either murine macrophage cell lines or human primary macrophages. FN also induced FAK-dependent/ligand-independent CSF-1R phosphorylation, as well as the interaction between CSF-1R and β1. CSF-1R activity was necessary for FN-induced macrophage migration. Indeed, genetic or pharmacological inhibition of CSF-1R prevented FN-induced macrophage migration. Our results identified a new SFK-FAK/CSF-1R signaling pathway that mediates FN-induced migration of macrophages.
2002-11-12
KENNEDY SPACE CENTER, FLA. -- In the Payload Changeout Room, Launch Pad 39A, workers raise a platform toward the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
2002-11-12
KENNEDY SPACE CENTER, FLA. -- Workers in the Payload Changeout Room, Launch Pad 39A, are on a platform in the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
2002-11-12
KENNEDY SPACE CENTER, FLA. -- Workers in the Payload Changeout Room, Launch Pad 39A, ride a platform toward the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
2002-11-12
KENNEDY SPACE CENTER, FLA. -- Workers in the Payload Changeout Room, Launch Pad 39A, are on a platform in the forward cargo bay area of Space Shuttle Endeavour to search for an oxygen leak. The launch of Endeavour on mission STS-113 was postponed Nov. 10, following the completion of tanking operations, due to higher than allowable oxygen levels in the orbiter's midbody. Workers will investigate the exact location and possible cause of the leak, and effect repairs. Launch has been tentatively set for no earlier than Nov. 18, between 7 and 11 p.m. EST.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knaab, H.; Knecht, K.
The need for pool-site inspection and examination of fuel assemblies was recognized by Kraftwerk Union Aktiengesellschaft with the commissioning of the first nuclear power stations. A wet sipping method has demonstrated high reliability in detection of leaking fuel assemblies. The visual inspection system is a versatile tool. It can be supplemented by attaching devices for oxide thickness measurement or surface replication. Repair of leaking pressurized water reactor fuel assemblies has improved fuel utilization. Applied methods and typical results are described.
In vitro conjunctival incision repair by temperature-controlled laser soldering.
Norman, Galia; Rabi, Yaron; Assia, Ehud; Katzir, Abraham
2009-01-01
The common method of closing conjunctival incisions is by suturing, which is associated with several disadvantages. It requires skill to apply and does not always provide a watertight closure, which is required in some operations (e.g., glaucoma filtration). The purpose of the present study was to evaluate laser soldering as an alternative method for closing conjunctival incisions. Conjunctival incisions of 20 ex vivo porcine eyes were laser soldered using a temperature-controlled fiberoptic laser system and an albumin mixed with indocyanine green as a solder. The control group consisted of five repaired incisions by a 10-0 nylon running suture. The leak pressure of the repaired incisions was measured. The mean leak pressure in the laser-soldered group was 132 mm Hg compared to 4 mm Hg in the sutured group. There was no statistically significant difference in both the incision's length and distance from the limbus between the groups, before and after the procedure, indicating that there was no severe thermal damage. These preliminary results clearly demonstrate that laser soldering may be a useful method for achieving an immediate watertight conjunctival wound closure. This procedure is faster and easier to apply than suturing.
The blood-cerebrospinal fluid barrier: structure and functional significance.
Johanson, Conrad E; Stopa, Edward G; McMillan, Paul N
2011-01-01
The choroid plexus (CP) of the blood-CSF barrier (BCSFB) displays fundamentally different properties than blood-brain barrier (BBB). With brisk blood flow (10 × brain) and highly permeable capillaries, the human CP provides the CNS with a high turnover rate of fluid (∼400,000 μL/day) containing micronutrients, peptides, and hormones for neuronal networks. Renal-like basement membranes in microvessel walls and underneath the epithelium filter large proteins such as ferritin and immunoglobulins. Type IV collagen (α3, α4, and α5) in the subepithelial basement membrane confers kidney-like permselectivity. As in the glomerulus, so also in CP, the basolateral membrane utrophin A and colocalized dystrophin impart structural stability, transmembrane signaling, and ion/water homeostasis. Extensive infoldings of the plasma-facing basal labyrinth together with lush microvilli at the CSF-facing membrane afford surface area, as great as that at BBB, for epithelial solute and water exchange. CSF formation occurs by basolateral carrier-mediated uptake of Na+, Cl-, and HCO3-, followed by apical release via ion channel conductance and osmotic flow of water through AQP1 channels. Transcellular epithelial active transport and secretion are energized and channeled via a highly dense organelle network of mitochondria, endoplasmic reticulum, and Golgi; bleb formation occurs at the CSF surface. Claudin-2 in tight junctions helps to modulate the lower electrical resistance and greater permeability in CP than at BBB. Still, ratio analyses of influx coefficients (Kin) for radiolabeled solutes indicate that paracellular diffusion of small nonelectrolytes (e.g., urea and mannitol) through tight junctions is restricted; molecular sieving is proportional to solute size. Protein/peptide movement across BCSFB is greatly limited, occurring by paracellular leaks through incomplete tight junctions and low-capacity transcellular pinocytosis/exocytosis. Steady-state concentration ratios, CSF/plasma, ranging from 0.003 for IgG to 0.80 for urea, provide insight on plasma solute penetrability, barrier permeability, and CSF sink action to clear substances from CNS.
NASA Astrophysics Data System (ADS)
Wilson, Jeffrey M.
This Dissertation investigates a carbon fiber reinforced polymer repair system for structurally deficient steel piping. Numerous techniques exist for the repair of high-pressure steel piping. One repair technology that is widely gaining acceptance is composite over-wraps. Thermal analytical evaluations of the epoxy matrix material produced glass transition temperature results, a cure kinetic model, and a workability chart. These results indicate a maximum glass transition temperature of 80°C (176°F) when cured in ambient conditions. Post-curing the epoxy, however, resulted in higher glass-transition temperatures. The accuracy of cure kinetic model presented is temperature dependent; its accuracy improves with increased cure temperatures. Cathodic disbondment evaluations of the composite over-wrap show the epoxy does not breakdown when subjected to a constant voltage of -1.5V and the epoxy does not allow corrosion to form under the wrap from permeation. Combustion analysis of the composite over-wrap system revealed the epoxy is flammable when in direct contact with fire. To prevent combustion, an intumescent coating was developed to be applied on the composite over-wrap. Results indicate that damaged pipes repaired with the carbon fiber composite over-wrap withstand substantially higher static pressures and exhibit better fatigue characteristics than pipes lacking repair. For loss up to 80 percent of the original pipe wall thickness, the composite over-wrap achieved failure pressures above the pipe's specified minimum yield stress during monotonic evaluations and reached the pipe's practical fatigue limit during cyclical pressure testing. Numerous repairs were made to circular, thru-wall defects and monotonic pressure tests revealed containment up to the pipe's specified minimum yield strength for small diameter defects. The energy release rate of the composite over-wrap/steel interface was obtained from these full-scale, leaking pipe evaluations and results indicate a large amount of scatter is associated with this test method. Due to the large amount of scatter present in the leaking pipe evaluations (energy release rate tests), a new laboratory specimen was created to evaluate mixed mode debonding of composite over-wrapped piping. The laboratory specimen results are much more conservative than the leaking pipe evaluations. The laboratory specimen results, however, agree quite favorably to a closed form solution developed in this Dissertation, as well as to energy release rate calculations performed by two different finite element analysis methods, the Modified Crack Closure Integral and the change in compliance method.
De Pasquale, Gabriella; Bonassin Tempesta, Francesca; Lopes, Bruno Santos; Babic, Daniela; Oxenius, Angela; Seeliger, Theresa; Gruner, Christiane; Tanner, Felix C; Biaggi, Patric; Attenhofer Jost, Christine; Greutmann, Matthias
2017-05-01
To determine the prevalence of baffle leaks in adults after atrial switch operations for transposition of the great arteries, as these may predispose to paradoxical embolic events, particularly in patients with transvenous pacemaker or defibrillator leads. We routinely perform contrast echocardiography with agitated saline in all patients after atrial switch operations. For this study, we analysed patients who had saline contrast echocardiography between 2010 and 2012. The presence of baffle leaks and the severity of right-to-left shunting were assessed. We compared baseline characteristics and oxygen saturation at rest and during exercise between patients with and without baffle leaks. A total of 65 patients (56 Senning and 9 Mustard repair) without previously known baffle leaks were included (mean age 32 ± 8 years, 77% males). Right-to-left shunting was identified in 42 patients (65%) and occurred without provocation manoeuvres in 88%. There were no differences in baseline characteristics, echocardiographic findings, or exercise capacity between patients with and without baffle leaks, except for lower oxygen saturation at peak exercise in those with baffle leaks (29% had oxygen saturations below 90% at peak exercise compared to none without baffle leaks, P = 0.011). Four patients with baffle leaks had previous implantation of transvenous pacemaker leads; one of them had suffered a stroke. Two other patients with baffle leaks had a history of potential embolic stroke. Because of the high prevalence of baffle leaks in adults after atrial switch operations, we propose routine screening with agitated saline contrast, particularly prior to implantation of transvenous pacemaker or defibrillator leads. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
40 CFR 415.381 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... process wastewater means any water which, during manufacturing or processing, comes into direct contact... wastewater. (d) The term contaminated nonprocess wastewater shall mean any water which, during manufacturing...) accidental leaks caused by the failure of process equipment, which are repaired within the shortest...
75 FR 59746 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-28
... refrigerant leak repair, testing, recordkeeping and reporting regulations at 40 CFR part 82, Subpart F, and... contain non-ozone depleting refrigerants. Defendant also agrees to pay a civil penalty in the amount of...
40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2011 CFR
2011-07-01
... provide output of relative or absolute particulate matter loadings. (5) The bag leak detection system must..., repairs, calibration checks, and zero and span adjustments, emissions data must be obtained by using other...
40 CFR 60.2730 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2011 CFR
2011-07-01
... system sensor must provide output of relative or absolute particulate matter loadings. (5) The bag leak..., repairs, calibration checks and zero and span adjustments, you must collect emissions data by using other...
Wu, L; Yu, Y L; Galiano, R D; Roth, S I; Mustoe, T A
1997-10-01
Macrophage colony-stimulating factor (M-CSF) is produced by many cell types involved in wound repair, yet it acts specifically on monocytes and macrophages. The monocyte-derived cell is thought to be important in wound healing, but the importance of the role of tissue macrophages in wound healing has not been well defined. Dermal ulcers were created in normal and ischemic ears of young rabbits. Either rhM-CSF (17 microg/wound) or buffer was applied to each wound. Wounds were bisected and analyzed histologically at Days 7 and 10 postwounding. The amounts of epithelial growth and granulation tissue deposition were measured in all wounds. The level of increase of TGF-beta1 mRNA level in M-CSF-treated wounds was examined using competitive RT-PCR. M-CSF increased new granulation tissue formation by 37% (N = 21, P < 0.01) and 50% (P < 0.01) after single and multiple treatments, respectively, in nonischemic wounds. TGF-beta1 mRNA levels in rhM-CSF-treated wounds increased 5.01-fold (N = 8) over vehicle-treated wounds under nonischemic conditions. In contrast, no effect could be detected in ischemic wounds treated with rhM-CSF, and these wounds only showed a 1.66-fold increase in TGF-beta1 mRNA levels when compared to ischemic wounds treated with vehicle alone. GAPDH, a housekeeping gene, showed no change. As mesenchymal cells lack receptors for M-CSF, the improved healing of wounds treated with topical rhM-CSF must reflect a generalized enhancement of activation and function of tissue macrophages, as demonstrated by upregulation of TGF-beta. The lack of effect under ischemic conditions suggests that either macrophage activity and/or response to M-CSF is adversely affected under those conditions; this may suggest the pathogenesis of impaired wound healing at the cellular level. Copyright 1997 Academic Press.
40 CFR 415.411 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... wastewater means any water which, during manufacturing or processing, comes into direct contact with or... wastewater. (d) The term contaminated nonprocess wastewater shall mean any water which, during manufacturing...) accidental leaks caused by the failure of process equipment, which are repaired within the shortest...
40 CFR 415.401 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... wastewater means any water which, during manufacturing or processing, comes into direct contact with or... wastewater. (d) The term contaminated nonprocess wastewater shall mean any water which, during manufacturing... leaks caused by the failure of process equipment, which are repaired within the shortest reasonable time...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2013 CFR
2013-07-01
... recognized association or an independent testing laboratory. Note: The following codes and standards may be used to comply with paragraph (a) of this section: National Fire Protection Association Standard 30... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2012 CFR
2012-07-01
... recognized association or an independent testing laboratory. Note: The following codes and standards may be used to comply with paragraph (a) of this section: National Fire Protection Association Standard 30... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2014 CFR
2014-07-01
... recognized association or an independent testing laboratory. Note: The following codes and standards may be used to comply with paragraph (a) of this section: National Fire Protection Association Standard 30... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention...
Isaza-Restrepo, Andres; Moreno-Mejia, Jose F; Martin-Saavedra, Juan S; Ibañez-Pinilla, Milciades
2017-01-01
There is a well known relationship between hypoperfusion and postoperative complications like anastomotic leak. No studies have been done addressing this relationship in the context of abdominal trauma surgery. Central venous oxygen saturation is an important hypoperfusion marker of potential use in abdominal trauma surgery for identifying the risk of anastomotic leak development. The purpose of this study was to identify the relationship between low values of central venous oxygen saturation and anastomotic leak of gastrointestinal sutures in the postoperative period in abdominal trauma surgery. A cross-sectional prospective study was performed. Patients over 14 years old who required surgical gastrointestinal repair secondary to abdominal trauma were included. Anastomotic leak diagnosis was confirmed through clinical manifestations and diagnostic images or secondary surgery when needed. Central venous oxygen blood saturation was measured at the beginning of surgery through a central catheter. Demographic data, trauma mechanism, anatomic site of trauma, hemoglobin levels, abdominal trauma index, and comorbidities were assessed as secondary variables. Patients who developed anastomotic leak showed lower mean central venous oxygen saturation levels (60.0% ± 2.94%) than those who did not (69.89% ± 7.21%) ( p = 0.010). Central venous oxygen saturation <65% was associated with the development of gastrointestinal leak during postoperative time of patients who underwent surgery secondary to abdominal trauma.
Dredla, Brynn; Freeman, William D
2016-04-01
Thunderclap headache is a sudden and severe headache that can occur after an aneurysmal subarachnoid hemorrhage (SAH). Subarachnoid hemorrhage is a medical emergency that requires prompt attention and hospitalization. Patients with thunderclap headache often undergo a noncontrast head computed tomography (CT) scan to ascertain SAH bleeding and, if the scan is negative, then undergo a lumbar puncture to look for cerebrospinal fluid (CSF) red blood cells (RBCs), which would be consistent with an aneurysmal leak. If the initial CT is negative and CSF is positive for RBCs, patients are usually admitted to the hospital for evaluation of intracranial aneurysm. We encountered a patient with thunderclap headache whose initial head CT was negative for SAH and whose CSF tested positive for RBCs. The patient was referred to our center for evaluation and management of aneurysmal SAH. However, on careful review of the patient's medical history, serum laboratory values, and spinal fluid values, the patient was diagnosed with Ehrlichia chaffeensis meningitis. While Ehrlichia meningitis is rare, it is important to recognize the clinical clues that could help avoid formal cerebral angiography, a costly and potentially unnecessary procedure. We present how this case represented a cognitive framing bias and anchoring heuristic as well as steps that medical providers can use to prevent such cognitive errors in diagnosis.
[Reconstructive surgery of cranio-orbital injuries].
Eolchiian, S A; Potapov, A A; Serova, N K; Kataev, M G; Sergeeva, L A; Zakharova, N E; Van Damm, P
2011-01-01
The aim of study was to optimize evaluation and surgery of cranioorbital injuries in different periods after trauma. Material and methods. We analyzed 374 patients with cranioorbital injuries treated in Burdenko Neurosurgery Institute in different periods after trauma from January 1998 till April 2010. 288 (77%) underwent skull and facial skeleton reconstructive surgery within 24 hours - 7 years after trauma. Clinical and CT examination data were used for preoperative planning and assessment of surgery results. Stereolithographic models (STLM) were applied for preoperative planning in 89 cases. The follow-up period ranged from 4 months up to 10 years. Results. In 254 (88%) of 288 patients reconstruction of anterior skull base, upper and/or midface with restoration of different parts of orbit was performed. Anterior skull base CSF leaks repair, calvarial vault reconstruction, maxillar and mandibular osteosynthesis were done in 34 (12%) cases. 242 (84%) of 288 patients underwent one reconstructive operation, while 46 (16%)--two and more (totally 105 operations). The patients with extended frontoorbital and midface fractures commonly needed more than one operation--in 27 (62.8%) cases. Different plastic materials were used for reconstruction in 233 (80.9%) patients, of those in 147 (51%) cases split calvarial bone grafts were preferred. Good functional and cosmetic results were achieved in 261 (90.6%) of 288 patients while acceptable were observed in 27 (9.4%). Conclusion. Active single-stage surgical management for repair of combined cranioorbital injury in acute period with primary reconstruction optimizes functional and cosmetic outcomes and prevents the problems of delayed or secondary reconstruction. Severe extended anterior skull base, upper and midface injuries when intracranial surgery is needed produced the most challenging difficulties for adequate reconstruction. Randomized trial is required to define the extent and optimal timing of reconstructive surgery in patients with severe traumatic brain injury and craniofacial injury in acute period of trauma.
Risk factors for baclofen pump infection in children: a multivariate analysis.
Spader, Heather S; Bollo, Robert J; Bowers, Christian A; Riva-Cambrin, Jay
2016-06-01
OBJECTIVE Intrathecal baclofen infusion systems to manage severe spasticity and dystonia are associated with higher infection rates in children than in adults. Factors unique to this population, such as poor nutrition and physical limitations for pump placement, have been hypothesized as the reasons for this disparity. The authors assessed potential risk factors for infection in a multivariate analysis. METHODS Patients who underwent implantation of a programmable pump and intrathecal catheter for baclofen infusion at a single center between January 1, 2000, and March 1, 2012, were identified in this retrospective cohort study. The primary end point was infection. Potential risk factors investigated included preoperative (i.e., demographics, body mass index [BMI], gastrostomy tube, tracheostomy, previous spinal fusion), intraoperative (i.e., surgeon, antibiotics, pump size, catheter location), and postoperative (i.e., wound dehiscence, CSF leak, and number of revisions) factors. Univariate analysis was performed, and a multivariate logistic regression model was created to identify independent risk factors for infection. RESULTS A total of 254 patients were evaluated. The overall infection rate was 9.8%. Univariate analysis identified young age, shorter height, lower weight, dehiscence, CSF leak, and number of revisions within 6 months of pump placement as significantly associated with infection. Multivariate analysis identified young age, dehiscence, and number of revisions as independent risk factors for infection. CONCLUSIONS Young age, wound dehiscence, and number of revisions were independent risk factors for infection in this pediatric cohort. A low BMI and the presence of either a gastrostomy or tracheostomy were not associated with infection and may not be contraindications for this procedure.
Do surgeon credentials affect the rate of incidental durotomy during spine surgery.
Murray, N J; Demetriades, A K; Rolton, D; Nnadi, C
2014-08-01
Incidental durotomy is a potential complication of spinal surgery which can cause a number of intra-operative and post-operative complications. The purpose of this study was to determine if the primary operator's credentials impacted on the incidence of durotomy intra-operatively. Prospectively collected data of operator credentials in relation to the incidence of durotomy were acquired from the International Eurospine Tango database. The significance of variability and risk factors between operators was measured using the Chi-squared test. Data from a total of 3,764 patients were captured from the Tango registry. Of these 162 (4.3%) had a durotomy. Of the total number of patients, the primary operator was neurosurgical in 1,369 (36.4%) cases; orthopaedic in 180 (4.8%) cases; other (pre-certification) in 236 (6.3%) cases; specialised spine surgeon in 1,741 (46.3%) cases; 6 cases had missing operator data. cerebrospinal fluid (CSF) leak occurred in 57 (4.16%) of neurosurgeon-operated cases; 5 (2.78%) orthopaedic-operated cases; 19 (4.06%) of other surgeon-operated cases; and 81 (4.65%) in specialised spine surgeon-operated cases. Using Chi-squared test, the significance of the variation in incidence of CSF leak between primary operator groups was not statistically significant (P = 0.1405). From the data captured and analysed, the rate of durotomy ranged from 2.78 to 4.65% between operator groups with a mean rate of 4.3%. The primary operator credentials do not appear to significantly impact the rate of durotomy in spine surgery.
Infection Rate in 1033 Elective Neurosurgical Procedures at a University Hospital in South China.
Zhu, Hongwei; Liu, Xiyao; Wang, Zhanxiang
2017-09-01
Objective Infection following surgery is a serious complication, especially in neurosurgery. The aim of the study is to report the change of incidence rates of infection in patients undergoing elective neurosurgical procedures at a university hospital in South China as well as the risk factors. Material and Methods The medical records and postoperative courses for patients undergoing 1,033 neurosurgical procedures from 2008 to 2014 were reviewed retrospectively to determine the incidence of neurosurgical infection, the identity of the offending organisms, and the factors associated with infection. Results A total of 33 patients (40 cases) experienced postoperative infection representing 3.19% of the study population. Twenty cases were incision infections (1.94%), and 20 were cranial/spinal infections (1.94%) including 15 intracranial infections and 5 intraspinal infections. The 2.4-fold greater incidence of postoperative infection in 2008 to 2010 was compared with that in 2011 to 2014 with perioperative antibiotic prophylaxis ( p <0.01). The neurosurgical procedure associated with the highest rate of infection was cranioplasty (6.85%); the lowest rate of infection was associated with functional neurosurgery (1.08%). The most common offending organism was Staphylococcus aureus (27.5%). Foreign body implantation, operative time > 4 hours, and cerebrospinal fluid (CSF) leak (13 infections in 158 patients; p <0.001) were risk factors for infections ( p <0.05). Conclusion The neurosurgical infection rate is usually low with perioperative antibiotic prophylaxis even in developing countries. Less foreign body implantation, shorter operative times, and controlling CSF leak could reduce infection rates. Georg Thieme Verlag KG Stuttgart · New York.
LOCATING AND REPAIRING LEAKS IN LANDFILL/IMPOUNDMENT FLEXIBLE MEMBRANE LINERS
In the United States, the large quantities of solid and hazardous wastes generated each year are commonly disposed of in landfills and surface impoundments. Geomembrane liners (flexible membrane liners, FMLs) are often used to form an impermeable barrier to prevent migration of c...
COPPER PITTING CORROSION: A CASE STUDY
Localized or pitting corrosion of copper pipes used in household drinking-water plumbing is a problem for many water utilities and their customers. Extreme attack can lead to pinhole water leaks that may result in water damage, mold growth, and costly repairs. Water quality has b...
40 CFR 82.156 - Required practices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... appliance to four inches of mercury vacuum. (i)(1) Owners or operators of commercial refrigeration equipment...) Owners or operators of federally-owned commercial refrigeration equipment may have more than 30 days to repair leaks if the refrigeration appliance is located in an area subject to radiological contamination...
40 CFR 82.156 - Required practices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... appliance to four inches of mercury vacuum. (i)(1) Owners or operators of commercial refrigeration equipment...) Owners or operators of federally-owned commercial refrigeration equipment may have more than 30 days to repair leaks if the refrigeration appliance is located in an area subject to radiological contamination...
40 CFR 82.156 - Required practices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... appliance to four inches of mercury vacuum. (i)(1) Owners or operators of commercial refrigeration equipment...) Owners or operators of federally-owned commercial refrigeration equipment may have more than 30 days to repair leaks if the refrigeration appliance is located in an area subject to radiological contamination...
40 CFR 82.156 - Required practices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... appliance to four inches of mercury vacuum. (i)(1) Owners or operators of commercial refrigeration equipment...) Owners or operators of federally-owned commercial refrigeration equipment may have more than 30 days to repair leaks if the refrigeration appliance is located in an area subject to radiological contamination...
ERIC Educational Resources Information Center
Steve, James
2005-01-01
Many school administrators protect their investments in new roofing systems by paying extra for an extended roof warranty. These warranties can be a valuable asset because they usually provide more coverage and reduce the school administrator's risk of having to pay for extensive roof repairs or replacements. Unfortunately, once an extended…
Benign Biliary Strictures and Leaks.
Devière, Jacques
2015-10-01
The major causes of benign biliary strictures include surgery, chronic pancreatitis, primary sclerosing cholangitis, and autoimmune cholangitis. Biliary leaks mainly occur after surgery and, rarely, abdominal trauma. These conditions may benefit from a nonsurgical approach in which endoscopic retrograde cholangiopancreatography (ERCP) plays a pivotal role in association with other minimally invasive approaches. This approach should be evaluated for any injury before deciding about the method for repair. ERCP, associated with peroral cholangioscopy, plays a growing role in characterizing undeterminate strictures, avoiding both unuseful major surgeries and palliative options that might compromise any further management. Copyright © 2015 Elsevier Inc. All rights reserved.
Huber, Bruno C; Fischer, Rebekka; Brunner, Stefan; Groebner, Michael; Rischpler, Christoph; Segeth, Alexander; Zaruba, Marc M; Wollenweber, Tim; Hacker, Marcus; Franz, Wolfgang-Michael
2010-05-01
Mobilization of stem cells by granulocyte colony-stimulating factor (G-CSF) was shown to have protective effects after myocardial infarction (MI); however, clinical trials failed to be effective. In search for alternative cytokines, parathyroid hormone (PTH) was recently shown to promote cardiac repair by enhanced neovascularization and cell survival. To compare the impact of the two cytokines G-CSF and PTH on myocardial perfusion, mice were noninvasively and repetitively investigated by pinhole single-photon emission computed tomography (SPECT) after MI. Mobilization and homing of bone marrow-derived stem cells (BMCs) was analyzed by fluorescence-activated cell sorter (FACS) analysis. Mice (C57BL/6J) were infarcted by left anterior descending artery ligation. PTH (80 mug/kg) and G-CSF (100 mug/kg) were injected for 5 days. Perfusion defects were determined by (99m)Tc-sestamibi SPECT at days 6 and 30 after MI. The number of BMCs characterized by Lin(-)/Sca-1(+)/c-kit(+) cells in peripheral blood and heart was analyzed by FACS. Both G-CSF and PTH treatment resulted in an augmented mobilization of BMCs in the peripheral blood. Contrary to G-CSF and controls, PTH and the combination showed significant migration of BMCs in ischemic myocardium associated with a significant reduction of perfusion defects from day 6 to day 30. A combination of both cytokines had no additional effects on migration and perfusion. In our preclinical model, SPECT analyses revealed the functional potential of PTH reducing size of infarction together with an enhanced homing of BMCs to the myocardium in contrast to G-CSF. A combination of both cytokines did not improve the functional outcome, suggesting clinical applications of PTH in ischemic heart diseases.
Liu, James K C
2018-06-01
Intracranial hypotension from cerebrospinal fluid (CSF) hypovolemia resulting in cerebral herniation is a rare but known complication that can occur after neurosurgical procedures, usually encountered in correlation with perioperative placement of a lumbar subarachnoid drain. Decrease in CSF volume resulting in loss of buoyancy results in downward herniation of the brain without contributing mass effect, causing a phenomenon known as brain sag. Unreported previously is brain sag occurring without concomitant occult CSF leak or lumbar drainage. This case report describes a patient who underwent bilateral craniotomies for subacute on chronic subdural hematoma with successful decompression but experienced acute neurologic deterioration secondary to brain sag. Despite an initial improvement in neurologic function, he subsequently experienced progressive neurologic deterioration with evidence of cerebral herniation on neuroimaging, without evidence of continued mass effect on the brain parenchyma. After a diagnosis of brain sag was determined based on imaging criteria, the patient was placed in a flat position, which resulted in rapid improvement in his neurologic function without any further intervention. This case is unique in comparison with previous reports of intracranial hypotension after craniotomy in that the symptoms were completely reversed with positioning alone, without any evidence of active or occult CSF drainage. This report emphasizes that the diagnosis of brain sag should be taken into consideration when there is an unknown reason for neurologic decline after craniotomy, particularly bilateral craniotomies, if the imaging indicates herniation with imaging findings consistent with intracranial hypotension, without evidence of overlying mass effect. Copyright © 2018 Elsevier Inc. All rights reserved.
Vendors unveil one-step fugitive emissions monitoring, management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walter, M.
1995-04-01
An alliance of manufacturers has developed a ``single-source solution`` for fugitive emissions monitoring. The LeakTracker{trademark} system combines barcode scans, and vapor detection and data collection capabilities to help companies comply with leak detection and repair requirements as mandated by the Environmental Protection Agency`s Method 21 guidelines. LeakTracker doubles productivity and helps eliminate human-error factors associated with fugitive emissions monitoring. Two-person teams, clipboard-and-pencil data entry, and manual data transcription are eliminated. By automating the process and integrating all components, a technician can monitor 500 points daily following Method 21 guidelines, compared to about 250 readings per day using other systems. LeakTrackermore » includes a handheld workstation, sampling probe and laser-scan barcode reader that fit in a vest worn by a field technician. The technician points the workstation toward a barcode tag and pulls the trigger, which initiates a barcode read and automatically records the time, date and location. While the detachable probe ``sniffs`` for emissions, an analyzer interface module converts the gas detection signal from analog to digital format, allowing data to be recorded by the workstation. LeakTracker has an accuracy rate of 1 part per million.« less
Veeravagu, Anand; Joseph, Richard; Jiang, Bowen; Lober, Robert M; Ludwig, Cassie; Torres, Roland; Singh, Harminder
2013-01-01
Endonasal procedures may be necessary during management of craniofacial trauma. When a skull base fracture is present, these procedures carry a high risk of violating the cranial vault and causing brain injury or central nervous system infection. A 52-year-old bicyclist was hit by an automobile at high speed. He sustained extensive maxillofacial fractures, including frontal and sphenoid sinus fractures (Fig. 1). He presented to the emergency room with brisk nasopharyngeal hemorrhage, and was intubated for airway protection. He underwent emergent stabilization of his nasal epistaxis by placement of a Foley catheter in his left nare and tamponade with the Foley balloon. A six-vessel angiogram showed no evidence of arterial dissection or laceration. Imaging revealed inadvertent insertion of the Foley catheter and deployment of the balloon in the frontal lobe (Fig. 2). The balloon was subsequently deflated and the Foley catheter removed. The patient underwent bifrontal craniotomy for dural repair of CSF leak. He also had placement of a ventriculoperitoneal shunt for development of post-traumatic hydrocephalus. Although the hospital course was a prolonged one, he did make a good neurological recovery. The authors review the literature involving violation of the intracranial compartment with medical devices in the settings of craniofacial trauma. Caution should be exercised while performing any endonasal procedure in the settings of trauma where disruption of the anterior cranial base is possible. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Endoscopic endonasal trans-sphenoid surgery of pituitary adenoma
Yadav, YR; Sachdev, S; Parihar, V; Namdev, H; Bhatele, PR
2012-01-01
Endoscopic endonasal trans-sphenoid surgery (EETS) is increasingly used for pituitary lesions. Pre-operative CT and MRI scans and peroperative endoscopic visualization can provide useful anatomical information. EETS is indicated in sellar, suprasellar, intraventricular, retro-infundibular, and invasive tumors. Recurrent and residual lesions, pituitary apoplexy and empty sella syndrome can be managed by EETS. Modern neuronavigation techniques, ultrasonic aspirators, ultrasonic bone curette can add to the safety. The binostril approach provides a wider working area. High definition camera is much superior to three-chip camera. Most of the recent reports favor EETS in terms of safety, quality of life and tumor resection, hospital stay, better endocrinological, and visual outcome as compared to the microscopic technique. Nasal symptoms, blood loss, operating time are less in EETS. Various naso-septal flaps and other techniques of CSF leak repair could help reduce complications. Complications can be further reduced after achieving the learning curve, good understanding of limitations with proper patient selection. Use of neuronavigation, proper post-operative care of endocrine function, establishing pituitary center of excellence and more focused residency and endoscopic fellowship training could improve results. The faster and safe transition from microscopic to EETS can be done by the team concept of neurosurgeon/otolaryngologist, attending hands on cadaveric dissection, practice on models, and observation of live surgeries. Conversion to a microscopic or endoscopic-assisted approach may be required in selected patients. Multi-modality treatment could be required in giant and invasive tumors. EETS appears to be a better surgical option in most pituitary adenoma. PMID:23188987
Laparoscopic repair of traumatic perforation of the urinary bladder.
Cottam, D; Gorecki, P J; Curvelo, M; Shaftan, G W
2001-12-01
Laparoscopy as a diagnostic modality in trauma has been reported. However, therapeutic laparoscopy for trauma remains a controversial subject. We present a case of laparoscopic repair of a traumatic bladder rupture. A 25-year-old man was brought to the emergency room after a head-on collision. Physical examination was unremarkable with the exception of gross hematuria upon insertion of a urinary catheter. Computed tomography scan of the abdomen demonstrated a small amount of free intraperitoneal fluid. An anteroposterior cystogram was obtained which showed no intraperitoneal or extraperitoneal leak. Repeat examinations of the abdomen revealed a mild tenderness in the lower abdomen. Because of the presence of unexplained free intraperitoneal fluid and equivocal signs of peritoneal irritation, exploratory laparoscopy was performed. Three 5-mm ports and a 5-mm laparoscope were used. Laparoscopic examination of the abdomen revealed a 4-cm rupture at the dome of the bladder. The laceration was sutured in two layers using an intracorporeal technique. The patient was discharged on the second postoperative day with indwelling urinary catheter. Eight days after the operation, a repeated cystogram revealed no evidence of leak. We believe that laparoscopic exploration for trauma in hemodynamically stable patients is feasible. The repair of simple intraabdominal injuries such as bladder rupture can be safely performed.
Corporate Publics and Rhetorical Strategies: The Case of Union Carbide's Bhopal Crisis.
ERIC Educational Resources Information Center
Ice, Richard
1991-01-01
Examines the role of rhetorical strategies in repairing damaged corporate relationships. Demonstrates the utility of an integrated model (multiple-publics concept and strategies of apologia) to corporate public relations through a case study of Union Carbide's justification of the Bhopal gas leak. (KEH)
24 CFR 3280.603 - General requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... welding, brazing, or soldering or by paint, wax, tar, or other leak-sealing or repairing agents. (v... piping. All piping, pipe threads, hangers, and support exposed to the weather, water, mud, and road hazard, and subject to damage therefrom, shall be painted, coated, wrapped, or otherwise protected from...
24 CFR 3280.603 - General requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... welding, brazing, or soldering or by paint, wax, tar, or other leak-sealing or repairing agents. (v... piping. All piping, pipe threads, hangers, and support exposed to the weather, water, mud, and road hazard, and subject to damage therefrom, shall be painted, coated, wrapped, or otherwise protected from...
24 CFR 3280.603 - General requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... welding, brazing, or soldering or by paint, wax, tar, or other leak-sealing or repairing agents. (v... piping. All piping, pipe threads, hangers, and support exposed to the weather, water, mud, and road hazard, and subject to damage therefrom, shall be painted, coated, wrapped, or otherwise protected from...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention Association Standard 631, “Spill Prevention, Minimum 10 Year Life Extension of Existing Steel Underground... pipe sections and fittings that have released product as a result of corrosion or other damage must be...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention Association Standard 631, “Spill Prevention, Minimum 10 Year Life Extension of Existing Steel Underground... pipe sections and fittings that have released product as a result of corrosion or other damage must be...
49 CFR 195.452 - Pipeline integrity management in high consequence areas.
Code of Federal Regulations, 2010 CFR
2010-10-01
...; or (D) Other technology that the operator demonstrates can provide an equivalent understanding of the... information, coating type and condition, and seam type; (iii) Leak history, repair history and cathodic protection history; (iv) Product transported; (v) Operating stress level; (vi) Existing or projected...
Endoscopic transnasal resection of anterior cranial fossa meningiomas.
de Divitiis, Enrico; Esposito, Felice; Cappabianca, Paolo; Cavallo, Luigi M; de Divitiis, Oreste; Esposito, Isabella
2008-01-01
The extended transnasal approach, a recent surgical advancements for the ventral skull base, allows excellent midline access to and visibility of the anterior cranial fossa, which was previously thought to be approachable only via a transcranial route. The extended transnasal approach allows early decompression of the optic canals, obviates the need for brain retraction, and reduces neurovascular manipulation. Between 2004 and 2007, 11 consecutive patients underwent transnasal resection of anterior cranial fossa meningiomas--4 olfactory groove (OGM) and 7 tuberculum sellae (TSM) meningiomas. Age at surgery, sex, symptoms, and imaging studies were reviewed. Tumor size and tumor extension were estimated, and the anteroposterior, vertical, and horizontal diameters were measred on MR images. Medical records, surgical complications, and outcomes of the patients were collected. A gross-total removal of the lesion was achieved in 10 patients (91%), and in 1 patient with a TSM only a near-total (> 90%) resection was possible. Four patients with preoperative visual function defect had a complete recovery, whereas 3 patients experienced a transient worsening of vision, fully recovered within few days. In 3 patients (2 with TSMs and 1 with an OGM), a postoperative CSF leak occurred, requiring a endoscopic surgery for skull base defect repair. Another patient (a case involving a TSM) developed transient diabetes insipidus. The operative time ranged from 6 to 10 hours in the OGM group and from 4.5 to 9 hours in the TSM group. The mean duration of the hospital stay was 13.5 and 10 days in the OGM and TSM groups, respectively. Six patients (3 with OGMs and 3 with TSMs) required a blood transfusion. Surgery-related death occurred in 1 patient with TSM, in whom the tumor was successfully removed. The technique offers a minimally invasive route to the midline anterior skull base, allowing the surgeon to avoid using brain retraction and reducing manipulation of the large vessels and optic apparatus; hastens postoperative recovery; and improves patient compliance. Further assessment and refinement are required, particularly because of the potential risk of CSF leakage. Other studies and longer follow-up periods are necessary to ascertain the benefits of the technique.
Mobile natural gas leak surveys indicate that two utilities have high false negative rates
NASA Astrophysics Data System (ADS)
von Fischer, J. C.; Brewer, P. E.; Chamberlain, S.; Gaylord, A.; von Fischer, J.
2016-12-01
In the distribution systems that carry natural gas to consumers, leaks need to be discovered for safety reasons and to reduce greenhouse gas emissions. However, few utilities have adopted newer laser-based technologies that have greater sensitivity and precision, and instead rely on "industry standard" equipment that is far less sensitive. In partnership with the Environmental Defense Fund and Google, we mapped natural gas leaks in the domains of two anonymous utilities (Utility "A" and "B") using high sensitivity Picarro methane analyzers in Google Street View Cars. Surprisingly, when we shared these results with utilities, their survey crews were unable to find most of the leaks that our survey indicated (84% in A and 80% in B). To investigate this phenomenon, our team visited a subset of the leaks in each utility domain (n=32 in A and n=30 in B), and worked alongside utility surveyors to search the leak indication area, using a Los Gatos Research ultraportable methane analyzer to pinpoint leak locations. We found evidence of natural gas leaks at 69% and 68% of the locations in Utilities A and B respectively where survey crews had found nothing. We describe this as a "false negative" rate for the utility because the utility survey falsely indicated that there was no leak at these locations. Of these false negatives, 7% (n=2 of 32 in A, n=2 of 30 in B) were determined to be Grade 1 leaks requiring immediate repair due to high safety risk. Instrument sensitivity appears to explain some of the false negative rates. In particular, use of some industry standard equipment appears to have created a false sense of confidence among utility surveyors that leaks were not present. However, there was also evidence of communication failures and that surveyors did not use optimal approaches in their search. Based on these findings, we suggest that: 1) mobile deployment of high-precision methane analyzers can help find more natural gas leaks, and 2) use of some hand-held survey instruments may lead to higher rates of false negatives in leak survey and 3) there may be room for improvement in leak survey methodologies.
Sousa, Paula; Castanheira, António; Martins, Diana; Pinho, Juliana; Araújo, Ricardo; Cancela, Eugénia; Ministro, Paula; Silva, Américo
2017-07-01
The use of self-expandable metal stents (SEMS) for the treatment of postoperative leaks of the upper gastrointestinal tract is already established. However, there are discrepancies between the relatively small caliber of the esophageal stents available and the postsurgical luminal size, which may determine an inadequate juxtaposition. As colonic stents have a bigger diameter, they might be more adequate. Additionally, stents with a larger diameter might have a lower risk of migration. The aim of this study was to evaluate the efficacy and complications associated with the use of colonic fully covered SEMS (FSEMS) in the treatment of postoperative leaks in critical patients. All patients with postoperative leaks of the upper gastrointestinal tract treated with colonic stents (Hanarostent® CCI) between 2010 and 2013 were retrospectively included. Four patients with postoperative leaks were treated with colonic SEMS. The underlying surgeries were a gastric bypass, an esophagogastrectomy for Boerhaave syndrome, a primary repair of esophagopleural fistula due to Boerhaave syndrome, and an esophagectomy due to esophageal cancer. The leaks were detected on average 17 days after the initial surgery. All patients needed admission to a critical care unit after index surgery. Stent placement was technically feasible in all patients. The median residence time of the stents was 7 weeks, and no complications were verified when they were removed. There were no cases of stent migration. The treatment was successful in all patients, with complete healing of the leaks. The placement of colonic FSEMS seems to be successful and safe in the treatment of postoperative leaks of the upper gastrointestinal tract.
Welding of hermetic connectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hieber, D.E.
1976-08-01
Certain systems use hermetically-sealed multipin connectors welded into a stainless steel support ring. Failure of these hermetic seals during welding continues to be a problem, and similar problems are anticipated on advanced systems. Since the assembly is expensive, and the detection, prevention, and repair of hermetic seal failures is costly, development of an improved welding process is important. Extended service life also requires a lower system leak rate, thus causing an increased need for maintaining the hermetic seal without supplemental epoxy sealing and repair. Experience shows that up to 70 percent of the 10-pin SA1810-2 connectors have gross leaks (greatermore » than 0.003 mm/sup 3//s Standard Temperature and Pressure (STP)) after being welded using established welding processes and without using the epoxy pre-seal process. Acceptable leak rates of less than 0.00001 mm/sup 3//s STP were achieved from 20 SA1810-2 10-pin connectors using heat sinks and an intermittent gas-tungsten-arc (GTA) weld technique. The process developed consists of using a massive copper heat sink with silicon thermal joint compound to maintain control of temperature in the hermetic seal area and using a 12-segment GTA weld with compressed argon gas cooling between weld segments. The process and techniques developed are considered acceptable for welding the SA1810 family of connectors.« less
MacAllister, Rhonda Pung; Lester McCully, Cynthia M; Bacher, John; Thomas, Marvin L; Cruz, Rafael; Wangari, Solomon; Warren, Katherine E
2016-01-01
Biomedical translational research frequently incorporates collection of CSF from NHP, because CSF drug levels are used as a surrogate for CNS tissue penetration in pharmacokinetic and dynamic studies. Surgical placement of a CNS ventricular catheter reservoir for CSF collection is an intensive model to create and maintain and thus may not be feasible or practical for short-term studies. Furthermore, previous NHP lumbar port models require laminectomy for catheter placement. The new model uses a minimally invasive technique for percutaneous placement of a lumbar catheter to create a closed, subcutaneous system for effective, repeated CSF sample collection. None of the rhesus macaques (Macaca mulatta; n = 10) implanted with our minimally invasive lumbar port (MILP) system experienced neurologic deficits, postoperative infection of the surgical site, or skin erosion around the port throughout the 21.7-mo study. Functional MILP systems were maintained in 70% of the macaques, with multiple, high-quality, 0.5- to 1.0-mL samples of CSF collected for an average of 3 mo by using aspiration or gravitational flow. Among these macaques, 57% had continuous functionality for a mean of 19.2 mo; 50% of the cohort required surgical repair for port repositioning and replacement during the study. The MILP was unsuccessful in 2 macaques, at an average of 9.5 d after surgery. Nonpatency in these animals was attributed to the position of the lumbar catheter. The MILP system is an appropriate replacement for temporary catheterization and previous models requiring laminectomy and is a short-term alternative for ventricular CSF collection systems in NHP. PMID:27538866
Mechanical Complication with Broviac Repair Kit in a 4-Year-Old Boy with MEN 2a.
Sesia, Sergio B; Haecker, Frank-Martin; Mayr, Johannes
2009-01-01
Background. Mechanical complications in the use of indwelling central venous catheters (CVCs) such as the Broviac catheter (BC) include kinking, occlusion, dislocation or leaking. We report on a mechanical complication after using a repair kit for the BC. Method. A 4-year old boy, suffering from multiple endocrine neoplasia type 2a (MEN 2a), intestinal aganglionosis (Hirschsprung's disease), and short bowel syndrome, required a BC for home parenteral nutrition. Result. Due to recurrent leakage of the BC, 5 subsequent repairs were necessary within seven months. During one repair a metallic tube belonging to the repair kit was found to have migrated proximally to the skin entrance level within the BC and requiring surgical removal. Conclusion. To our knowledge, this is the first report focusing on such a serious complication using a BC and its repair kit. The proximal migration of this metallic tube constitutes a distinct theoretical risk of endothoracic foreign body embolization.
2002-04-04
KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39B, an inspection team gathers at the foot of Mobile Launcher Platform where Space Shuttle Atlantis sits. Earlier today a leak in a ground support liquid hydrogen vent line on the south side of the Mobile Launcher Platform caused a scrub of the launch of Atlantis on mission STS-110. An engineering team is assessing the situation to determine the best method to repair the hydrogen line. The turnaround plan includes time to perfor weld repairs and return the vehicle to a timeline to resume the countdown
2002-04-04
KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39B, workers on a crane inspect pipes on the Mobile Launcher Platform where Space Shuttle Atlantis sits. Earlier today a leak in a ground support liquid hydrogen vent line on the south side of the Mobile Launcher Platform caused a scrub of the launch of Atlantis on mission STS-110. An engineering team is assessing the situation to determine the best method to repair the hydrogen line. The turnaround plan includes time to perfor weld repairs and return the vehicle to a timeline to resume the countdown
29 CFR 1915.7 - Competent person.
Code of Federal Regulations, 2012 CFR
2012-07-01
... testing to the following situations: (i) Repair work on small craft in boat yards where only combustible gas indicator tests are required for fuel tank leaks or when using flammable paints below decks; (ii... is required; (iii) The breaking of vessels where there is no fuel oil or other flammable hazard; and...
29 CFR 1915.7 - Competent person.
Code of Federal Regulations, 2014 CFR
2014-07-01
... testing to the following situations: (i) Repair work on small craft in boat yards where only combustible gas indicator tests are required for fuel tank leaks or when using flammable paints below decks; (ii... is required; (iii) The breaking of vessels where there is no fuel oil or other flammable hazard; and...
Pitting Corrosion of Copper in Waters with High pH and Low Alkalinity
Localized or pitting corrosion of copper pipes used in household drinking-water plumbing is a problem for many water utilities and their customers. Extreme attack can lead to pinhole water leaks that may result in water damage, mold growth, and costly repairs. Water quality has b...
75 FR 65032 - Notice of Lodging of Consent Decree
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-21
... absorber vent as a Group 2 process vent under the Hazardous Organic NESHAP regulations. For three years, Westlake will also implement an enhanced Leak Detection and Repair program to control emissions of...'s common control, and Westlake will not contest administratively or judicially a finding by the...
40 CFR 63.148 - Leak inspection provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards for Organic Hazardous Air Pollutants From the Synthetic Organic Chemical Manufacturing Industry... would be exposed to an imminent or potential danger as a consequence of complying with paragraphs (b)(1...) whose decision it was that repair could not be effected without a shutdown. (vi) The expected date of...
Of Detection Limits and Effective Mitigation: The Use of Infrared Cameras for Methane Leak Detection
NASA Astrophysics Data System (ADS)
Ravikumar, A. P.; Wang, J.; McGuire, M.; Bell, C.; Brandt, A. R.
2017-12-01
Mitigating methane emissions, a short-lived and potent greenhouse gas, is critical to limiting global temperature rise to two degree Celsius as outlined in the Paris Agreement. A major source of anthropogenic methane emissions in the United States is the oil and gas sector. To this effect, state and federal governments have recommended the use of optical gas imaging systems in periodic leak detection and repair (LDAR) surveys to detect for fugitive emissions or leaks. The most commonly used optical gas imaging systems (OGI) are infrared cameras. In this work, we systematically evaluate the limits of infrared (IR) camera based OGI system for use in methane leak detection programs. We analyze the effect of various parameters that influence the minimum detectable leak rates of infrared cameras. Blind leak detection tests were carried out at the Department of Energy's MONITOR natural gas test-facility in Fort Collins, CO. Leak sources included natural gas wellheads, separators, and tanks. With an EPA mandated 60 g/hr leak detection threshold for IR cameras, we test leak rates ranging from 4 g/hr to over 350 g/hr at imaging distances between 5 ft and 70 ft from the leak source. We perform these experiments over the course of a week, encompassing a wide range of wind and weather conditions. Using repeated measurements at a given leak rate and imaging distance, we generate detection probability curves as a function of leak-size for various imaging distances, and measurement conditions. In addition, we estimate the median detection threshold - leak-size at which the probability of detection is 50% - under various scenarios to reduce uncertainty in mitigation effectiveness. Preliminary analysis shows that the median detection threshold varies from 3 g/hr at an imaging distance of 5 ft to over 150 g/hr at 50 ft (ambient temperature: 80 F, winds < 4 m/s). Results from this study can be directly used to improve OGI based LDAR protocols and reduce uncertainty in estimated mitigation effectiveness. Furthermore, detection limits determined in this study can be used as standards to compare new detection technologies.
Isolation and Differentiation of Murine Macrophages.
Rios, Francisco J; Touyz, Rhian M; Montezano, Augusto C
2017-01-01
Macrophages play a major role in inflammation, wound healing, and tissue repair. Infiltrated monocytes differentiate into different macrophage subtypes with protective or pathogenic activities in vascular lesions. In the heart and vascular tissues, pathological activation promotes cardiovascular inflammation and remodeling and there is increasing evidence that macrophages play important mechanisms in this environment. Primary murine macrophages can be obtained from: bone marrow by different treatments (granulocyte-macrophage colony-stimulating factor-GM-CSF, macrophage colony-stimulating factor-M-CSF or supernatant of murine fibroblast L929), peritoneal cavity (resident or thioglycolate elicit macrophages), from the lung (alveolar macrophages) or from adipose tissue. In this chapter we describe some protocols to obtain primary murine macrophages and how to identify a pure macrophage population or activation phenotypes using different markers.
Mukherjee, Debraj; Pressman, Barry D; Krakow, Deborah; Rimoin, David L; Danielpour, Moise
2014-09-01
Achondroplasia may be associated with compression at the cervicomedullary junction. Determining which patients are at greatest risk for neurological complications of cervicomedullary compression can be difficult. In the current study the authors reviewed their records to determine the incidence and clinical significance of dynamic cervicomedullary stenosis and obstruction of CSF flow along with surgical outcomes following posterior fossa decompression. The authors reviewed 34 consecutive cases involving symptomatic children with achondroplasia undergoing cervicomedullary decompression performed by a single surgeon over 11 years. Of these patients, 29 had undergone preoperative dynamic MRI of the cervicomedullary junction with cine (cinema) CSF flow studies; 13 of these patients underwent postoperative dynamic MRI studies. Clinical outcomes included changes in polysomnography, head circumference percentile, and fontanel characteristics. Radiographic outcomes included changes in dynamic spinal cord diameter, improvement in CSF flow at the foramen magnum, and change in the Evans ratio. Patients were predominantly female, with a mean age at presentation of 6.6 years and mean follow-up of 3.7 years (range 1-10 years). All patients had moderate to excellent improvement in postoperative polysomnography, slight decrease in average head circumference percentile (from 46.9th percentile to 45.7th percentile), and no subjective worsening of fontanel characteristics. The Evans ratio decreased by 2%, spinal cord diameter increased an average of 3.1 mm, 5.2 mm, and 0.2 mm in the neutral, flexed, and extended positions, respectively, and CSF flow improved qualitatively in all 3 positions. There were no postoperative infections, CSF leaks, or other major complications. None of the patients undergoing initial foramen magnum decompression performed at our medical center required reoperation. Patients with achondroplasia and symptomatic cervicomedullary compression have increased risk of dynamic stenosis at the foramen magnum evident upon dynamic cine MRI. Operative decompression may be offered with low risk of complications or need for reoperation.
Acoustical Detection Of Leakage In A Combustor
NASA Technical Reports Server (NTRS)
Puster, Richard L.; Petty, Jeffrey L.
1993-01-01
Abnormal combustion excites characteristic standing wave. Acoustical leak-detection system gives early warning of failure, enabling operating personnel to stop combustion process and repair spray bar before leak grows large enough to cause damage. Applicable to engines, gas turbines, furnaces, and other machines in which acoustic emissions at known frequencies signify onset of damage. Bearings in rotating machines monitored for emergence of characteristic frequencies shown in previous tests associated with incipient failure. Also possible to monitor for signs of trouble at multiple frequencies by feeding output of transducer simultaneously to multiple band-pass filters and associated circuitry, including separate trigger circuit set to appropriate level for each frequency.
2009-06-24
CAPE CANAVERAL, Fla. – The afternoon sun casts shadows on space shuttle Endeavour's external fuel tank as workers remove the seal from the Ground Umbilical Carrier Plate, or GUCP, on the tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, the ground umbilical carrier plate (GUCP) is removed from space shuttle Discovery's external fuel tank. A hydrogen gas leak at that location during tanking for Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers examine the ground umbilical carrier plate (GUCP). A hydrogen gas leak at that location on the external fuel tank during tanking for space shuttle Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers examine the ground umbilical carrier plate (GUCP). A hydrogen gas leak at that location on the external fuel tank during tanking for space shuttle Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers remove the ground umbilical carrier plate (GUCP) from space shuttle Discovery's external fuel tank. A hydrogen gas leak at that location during tanking for Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, work continues on removing the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
Tomasello, Francesco; Esposito, Felice; Abbritti, Rosaria V; Angileri, Filippo F; Conti, Alfredo; Cardali, Salvatore M; La Torre, Domenico
2016-10-01
Microvascular decompression (MVD) represents the most effective and safe surgical option for the treatment of trigeminal neuralgia since it was first popularized by Jannetta 50 years ago. Despite several advances, complications such as cerebellar and vascular injury, hearing loss, muscular atrophy, cerebrospinal fluid (CSF) leak, postoperative cutaneous pain, and sensory disturbances still occur and may negatively affect the outcome. We propose some technical nuances of the surgical procedure that were used in our recent series. We used a novel hockey stick-shaped retromastoid skin incision, preserving the major nerves of the occipital and temporal areas. Microsurgical steps were performed without the use of retractors. CSF leakage was prevented with a watertight dural closure and multilayer osteodural reconstruction. The refined surgical steps were perfected in the last consecutive 15 cases of our series. In these cases we did not record any cutaneous pain, sensory disturbances, or CSF leakage. The average diameter of the craniectomy was 18 mm. No patient reported major complications related to the intradural microsurgical maneuvers. In all cases the neurovascular conflict was found and solved with a good outcome in terms of pain disappearance. Our minimally invasive approach was demonstrated to guarantee an optimal exposure of the cerebellopontine angle and minimize the rate of complications related to skin incision and muscular dissection, microsurgical steps, and closure. Copyright © 2016 Elsevier Inc. All rights reserved.
Chang, Catherine K; Chuter, Timothy A M; Reilly, Linda M; Ota, Maile K; Furtado, Andre; Bucci, Monica; Wintermark, Max; Hiramoto, Jade S
2008-06-01
To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. A retrospective review was conducted of 37 patients (27 men; mean age 74.8+/-7.1 years, range 58-86) undergoing endovascular TAAA repair with branched stent-grafts at a single academic institution from July 2005 to December 2007. Data were collected on preoperative comorbidities, duration of operation, blood loss, type of anesthesia, extent of aortic coverage, blood pressure, cerebrospinal fluid (CSF) pressure and drainage, and postoperative development of LEW. Pre- and postoperative contrast-enhanced computed tomographic angiograms (CTA) in a 26-patient subset were analyzed to evaluate the number of patent intercostal and lumbar arteries before and after repair. All patients were neurologically intact at the end of the operation. Seven (19%) patients developed LEW postoperatively: 6 perioperatively and 1 after discharge. LEW was associated with postoperative hypotension, internal iliac artery (IIA) occlusion, and fewer patent segmental arteries on preoperative CTA. Lowest mean systolic blood pressure was <90 mmHg in all 6 (100%) patients who developed LEW in hospital compared to 12 (44%) of the 27 patients who did not develop LEW (p = 0.02). Complete resolution of LEW (n = 4) followed prompt measures to raise blood pressure and lower CSF pressure. Persistent LEW (n = 3) was associated with sustained hypotension from sepsis, postoperative bleeding, and hemodialysis, respectively. Two (29%) of 7 patients with LEW either lost prograde flow to an IIA during repair or had bilaterally occluded IIAs preoperatively compared to 2 (7%) of 30 patients without LEW (p = 0.16). Comparison of pre- and postoperative CTAs showed no reduction in the mean number of patent segmental arteries in patients with or without LEW. Endovascular TAAA repair inevitably occludes direct inflow to lumbar and intercostal arteries. The distal segments of these arteries to the spine, however, are seen to remain patent through collaterals. Measures to preserve collateral pathways and increase perfusion pressure may help prevent or treat LEW.
Murphy, Meghan E; McCutcheon, Brandon A; Kerezoudis, Panagiotis; Porter, Amanda; Rinaldo, Lorenzo; Shepherd, Daniel; Rayan, Tarek; Maloney, Patrick R; Carter, Bob S; Bydon, Mohamad; Gompel, Jamie J Van; Link, Michael J
2016-09-01
Obesity has been associated with increased risk for postoperative CSF leak in patients with benign cranial nerve tumors. Other measures of postoperative morbidity associated with obesity have not been well characterized. Patients enrolled in the American College of Surgeons' National Surgical Quality Improvement Program (ACS-NSQIP) from 2007 to 2013 with a diagnosis code of a benign neoplasm of a cranial nerve were included. The primary outcome of postoperative morbidity was analyzed as well as secondary outcomes of readmission and reoperation. The main covariate of interest was body mass index (BMI). A total of 561 patients underwent surgery for a benign cranial nerve neoplasm between 2007 and 2013. Readmission data, available for 2012-2013(n=353), revealed hydrocephalus, facial nerve injury, or CSF leak requiring readmission or reoperation occurred in 0.85%, 1.42%, and 3.12%, respectively. Composite morbidity included wound complications, infection, respiratory insufficiency, transfusion requirement, stroke, venous thromboembolism, coma and cardiac arrest. On multivariable analysis patients with class I (BMI 30-34.9) and II (BMI 35-39.9) obesity showed trends towards increasing return to operating room, though not significant, but there was no trend for composite complications in class I and II obesity patients. However, class III obesity, BMI≥40, was associated with increased odds of composite morbidity (OR 4.40, 95% CI 1.24-15.88) and return to the operating room (OR 5.97, 95% CI 1.20-29.6) relative to patients with a normal BMI, 18.5-25. Obesity is an independent and important risk factor for composite morbidity in resection of benign cranial nerve neoplasms, and as such, merits discussion during preoperative counseling. Copyright © 2016 Elsevier B.V. All rights reserved.
Cellular and synaptic effect of substance P on neonatal phrenic motoneurons.
Ptak, K; Konrad, M; Di Pasquale, E; Tell, F; Hilaire, G; Monteau, R
2000-01-01
Experiments were carried out on the in vitro brainstem-spinal cord preparation of the newborn rat to analyse the effects of substance P (SP) on phrenic motoneuron (PMN) activity. In current-clamp mode, SP significantly depolarized PMNs, increased their input resistance, decreased the rheobase current and shifted the firing frequency-intensity relationships leftwards, but did not affect spike frequency adaptation or single spike configuration. The neurokinin receptor agonist NK1 had SP-mimetic effects, whereas the NK3 and NK2 receptor agonists were less effective and ineffective, respectively. In a tetrodotoxin-containing aCSF, only SP or the NK1 receptor agonist were still active. No depolarization was observed when the NK1 receptor agonist was applied in the presence of muscarine. In voltage-clamp mode, SP or the NK1 receptor agonist produced an inward current (ISP) which was not significantly reduced by extracellular application of tetraethylammonium, Co2+, 4-aminopyridine or Cs+. In aCSF containing tetrodotoxin, Co2+ and Cs+, ISP was blocked by muscarine. No PMN displayed any M-type potassium current but only a current showing no voltage sensitivity over the range -100 to 0 mV, reversing near the expected EK +, hence consistent with a leak current. SP application to the spinal cord only (using a partitioned chamber) significantly increased the phrenic activity. Pretreatment with the NMDA receptor antagonist DL-2-amino-5-phosphonovaleric acid (AP5) decreased the C4 discharge duration and blocked the effect of SP, thus exhibiting an NMDA potentiation by SP. In conclusion, SP modulates postsynaptically the response of phrenic motoneurons to the inspiratory drive through the reduction of a leak conductance and the potentiation of the NMDA component of the synaptic input.
Pure endoscopic expanded endonasal approach for olfactory groove and tuberculum sellae meningiomas.
Khan, Osaama H; Krischek, Boris; Holliman, Damian; Klironomos, George; Kucharczyk, Walter; Vescan, Allan; Gentili, Fred; Zadeh, Gelareh
2014-06-01
The expanded endoscopic endonasal (EEE) approach for the removal of olfactory groove (OGM) and tuberculum sellae (TSM) meningiomas is currently becoming an acceptable surgical approach in neurosurgical practice, although it is still controversial with respect to its outcomes, indications and limitations. Here we provide a review of the available literature reporting results with use of the EEE approach for these lesions together with our experience with the use of the endoscope as the sole means of visualization in a series of patients with no prior surgical biopsy or resection. Surgical cases between May 2006 and January 2013 were retrospectively reviewed. Twenty-three patients (OGM n=6; TSM n=17) were identified. In our series gross total resection (GTR) was achieved in 4/6 OGM (66.7%) and 11/17 (64.7%) TSM patients. Vision improved in the OGM group (2/2) and 8/11 improved in the TSM group with no change in visual status in the remaining three patients. Post-operative cerebrospinal fluid (CSF) leak occurred in 2/6 (33%) OGM and 2/17 (11.8%) TSM patients. The literature review revealed a total of 19 OGM and 174 TSM cases which were reviewed. GTR rate was 73% for OGM and 56.3% for TSM. Post-operative CSF leak was 30% for OGM and 14% for TSM. With careful patient selection and a clear understanding of its limitations, the EEE technique is both feasible and safe. However, longer follow-ups are necessary to better define the appropriate indications and ideal patient population that will benefit from the use of these newer techniques. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Closure of ascites leaks with fibrin glue injection in patients with end-stage liver disease.
Sadik, Karim W; Laibstain, Sarah; Northup, Patrick G; Kashmer, David; Schmitt, Timothy M; Bonatti, Hugo J R
2011-09-01
Ascites leaks (AL) in patients with end-stage liver disease (ESLD) are associated with significant morbidity and mortality regardless if they are medically or surgically managed. In a pilot study, 14 ESLD patients with AL underwent treatment with fibrin glue injection around the leak after failing conservative therapy. The end point of this study was the cessation of AL in the short term and the maintenance of a leak-free abdomen in the long term, allowing for medical optimization of the patients. Median age of the 10 men and 4 women was 50 (range 26-67) years. Underlying ESLDs were chronic hepatitis C (n=5), alcoholic LD (n=2), cryptogenic cirrhosis (n=2), and miscellaneous (n=5). There were six leaking incisions posthernia repair (three umbilical and three inguinal), two leaking/ruptured umbilical hernias, four leaking paracentesis sites, one leaking Jackson-Pratt (JP) drain canal, and one leaking laparoscopic trocar site. Average AL volume per day was 1000 (range 400-2000) mL. All leaks were immediately resolved with a 3-5 mL fibrin glue injection. Five recurred and required a second injection (four within 24 hours). Mental status improved in 7 patients (West Haven Criteria: grade II to I [n=6], grade III to I [n=1]). Median model of end-stage liver disease scores improved from 23 (range 8-33) to 20 (range 14-26). There were no infections, bleeds, or other injection-related complications. Average follow-up for these patients was 441.6 days (range 2-852). Five patients underwent liver transplant (LT) median 15 (range 4-270) days postinjection; 2 of them died. Another 3 patients died (2 from sepsis and 1 from metastatic cancer). Fibrin glue injection for the control of AL is a simple and safe bedside procedure that quickly controls AL, allowing for patient recovery in anticipation of further care.
Two-stream Convolutional Neural Network for Methane Emissions Quantification
NASA Astrophysics Data System (ADS)
Wang, J.; Ravikumar, A. P.; McGuire, M.; Bell, C.; Tchapmi, L. P.; Brandt, A. R.
2017-12-01
Methane, a key component of natural gas, has a 25x higher global warming potential than carbon dioxide on a 100-year basis. Accurately monitoring and mitigating methane emissions require cost-effective detection and quantification technologies. Optical gas imaging, one of the most commonly used leak detection technology, adopted by Environmental Protection Agency, cannot estimate leak-sizes. In this work, we harness advances in computer science to allow for rapid and automatic leak quantification. Particularly, we utilize two-stream deep Convolutional Networks (ConvNets) to estimate leak-size by capturing complementary spatial information from still plume frames, and temporal information from plume motion between frames. We build large leak datasets for training and evaluating purposes by collecting about 20 videos (i.e. 397,400 frames) of leaks. The videos were recorded at six distances from the source, covering 10 -60 ft. Leak sources included natural gas well-heads, separators, and tanks. All frames were labeled with a true leak size, which has eight levels ranging from 0 to 140 MCFH. Preliminary analysis shows that two-stream ConvNets provides significant accuracy advantage over single steam ConvNets. Spatial stream ConvNet can achieve an accuracy of 65.2%, by extracting important features, including texture, plume area, and pattern. Temporal stream, fed by the results of optical flow analysis, results in an accuracy of 58.3%. The integration of the two-stream ConvNets gives a combined accuracy of 77.6%. For future work, we will split the training and testing datasets in distinct ways in order to test the generalization of the algorithm for different leak sources. Several analytic metrics, including confusion matrix and visualization of key features, will be used to understand accuracy rates and occurrences of false positives. The quantification algorithm can help to find and fix super-emitters, and improve the cost-effectiveness of leak detection and repair programs.
Tyk2 as a target for immune regulation in human viral/bacterial pneumonia.
Berg, Johanna; Zscheppang, Katja; Fatykhova, Diana; Tönnies, Mario; Bauer, Torsten T; Schneider, Paul; Neudecker, Jens; Rückert, Jens C; Eggeling, Stephan; Schimek, Maria; Gruber, Achim D; Suttorp, Norbert; Hippenstiel, Stefan; Hocke, Andreas C
2017-07-01
The severity and lethality of influenza A virus (IAV) infections is frequently aggravated by secondary bacterial pneumonia. However, the mechanisms in human lung tissue that provoke this increase in fatality are unknown and therapeutic immune modulatory options are lacking.We established a human lung ex vivo co-infection model to investigate innate immune related mechanisms contributing to the susceptibility of secondary pneumococcal pneumonia.We revealed that type I and III interferon (IFN) inhibits Streptococcus pneumoniae -induced interleukin (IL)-1β release. The lack of IL-1β resulted in the repression of bacterially induced granulocyte-macrophage colony-stimulating factor (GM-CSF) liberation. Specific inhibition of IFN receptor I and III-associated tyrosine kinase 2 (Tyk2) completely restored the S. pneumoniae -induced IL-1β-GM-CSF axis, leading to a reduction of bacterial growth. A preceding IAV infection of the human alveolus leads to a type I and III IFN-dependent blockade of the early cytokines IL-1β and GM-CSF, which are key for orchestrating an adequate innate immune response against bacteria. Their virally induced suppression may result in impaired bacterial clearance and alveolar repair.Pharmacological inhibition of Tyk2 might be a new treatment option to sustain beneficial endogenous GM-CSF levels in IAV-associated secondary bacterial pneumonia. Copyright ©ERS 2017.
NASA Astrophysics Data System (ADS)
Weller, Z.; Hoeting, J.; von Fischer, J.
2017-12-01
Pipeline systems that distribute natural gas (NG) within cities can leak, leading to safety hazards and wasted product. Moreover, these leaks are climate-altering because NG is primarily composed of methane, a potent greenhouse gas. Scientists have recently developed an innovative method for mapping NG leak locations by installing atmospheric methane analyzers on Google Street View cars. We develop new statistical methodology to answer key inferential questions using data collected by these mobile air monitors. The new calibration-capture-recapture (CCR) model utilizes data from controlled methane releases and data collected by GSV cars to provide inference for several desired quantities, including the number of undetected methane sources and the total methane output rate in a surveyed region. The CCR model addresses challenges associated with using a capture-recapture model to analyze data collected by a mobile detection system including variable sampling effort and lack of physically marking individuals. We develop a Markov chain Monte Carlo algorithm for parameter estimation and apply the CCR model to methane data collected in two U.S. cities. The CCR model provides a new framework for inferring the total number of leaks in NG distribution systems and offers critical insights for informing intelligent repair policy that is both cost-effective and environmentally friendly.
Spontaneous intracranial hypotension.
Gordon, Neil
2009-12-01
Since the introduction of magnetic resonance imaging (MRI), spontaneous intracranial hypotension has been diagnosed much more frequently. The aim of this review is to discuss the symptoms and signs of the condition, in particular the characteristics of the associated headache, with sudden onset after sitting or standing, so that it can be included under the rubric of 'thunderclap headache'. This type of headache, like post lumbar puncture headaches, may be caused by cerebral vasodilatation and exacerbated by lowered pressure of the cerebrospinal fluid (CSF). Other symptoms include neck stiffness, nausea, vomiting, vertigo, tinnitus, deafness, and cognitive abnormalities. The clinical picture can sometimes mimic frontotemporal dementia, and the behaviour of some patients can sometimes be described as hypoactive-hypoalert, with somnolence, impaired attention, and stereotyped motor activity. Sagging of the brain, caused by leakeage of the CSF, can cause lesions in the brainstem with stupor, gaze palsies, and cranial nerve palsies. The condition can be a risk factor for cerebral venous thrombosis because of slowing of the blood flow and distortion of the blood vessels. The clinical picture may well suggest the diagnosis, but the headache may possibly indicate a subarachnoid haemorrhage. However, MRI will help to confirm the diagnosis and to localize the site of the CSF leak. MRI myelograms are of particular value, but if they are equivocal a computed tomography myelogram should be performed. The leakage of CSF is due to a tear in the dura, most frequently where the spinal roots leave the subarachnoid space. If this does not heal with bedrest, an epidural blood patch or a percutaneous injection of fibrin glue may be needed. More information is required on long-term follow-up.
Mounier, Roman; Lobo, David; Cook, Fabrice; Martin, Mathieu; Attias, Arie; Aït-Mamar, Bouziane; Gabriel, Inanna; Bekaert, Olivier; Bardon, Jean; Nebbad, Biba; Plaud, Benoît; Dhonneur, Gilles
2015-01-01
Ventriculostomy-related infection (VRI) is a serious complication of external ventricular drain (EVD) but its natural history is poorly studied. We prospectively tracked the bacteria pathways from skin towards ventricles to identify the infectious process resulting in ventriculostomy-related colonization (VRC), and VRI. We systematically sampled cerebrospinal fluid (CSF) on a daily basis and collected swabs from both the skin and stopcock every 3.0 days for microbiological analysis including in 101 neurosurgical patient. Risk factors for positive event defined as either VRC or VRI were recorded and related to our microbiological findings. A total of 1261 CSF samples, 473 skin swabs, and 450 stopcock swabs were collected. Skin site was more frequently colonized than stopcock (70 (60%) vs 34 (29%), p = 0.023), and earlier (14 ±1.4 vs 24 ±1.5 days, p<0.0001). Sixty-one (52%) and 32 (27%) skin and stopcock sites were colonized with commensal bacteria, 1 (1%) and 1 (1%) with pathogens, 8 (7%) and 1 (1%) with combined pathogens and commensal bacteria, respectively. Sixteen positive events were diagnosed; a cutaneous origin was identified in 69% of cases. The presence of a pathogen at skin site (6/16 vs 4/85, OR: 11.8, [2.5-56.8], p = 0.002) and CSF leakage (7/16 vs 6/85, OR 10 [2.4-41.2], p = 0.001)) were the two independent significant risk factors statistically linked to positive events occurrence. Our results suggest that VRC and VRI mainly results from an extra-luminal progression of pathogens initially colonizing the skin site where CSF leaks.
Cook, Fabrice; Martin, Mathieu; Attias, Arie; Aït-Mamar, Bouziane; Gabriel, Inanna; Bekaert, Olivier; Bardon, Jean; Nebbad, Biba; Plaud, Benoît; Dhonneur, Gilles
2015-01-01
Ventriculostomy-related infection (VRI) is a serious complication of external ventricular drain (EVD) but its natural history is poorly studied. We prospectively tracked the bacteria pathways from skin towards ventricles to identify the infectious process resulting in ventriculostomy-related colonization (VRC), and VRI. We systematically sampled cerebrospinal fluid (CSF) on a daily basis and collected swabs from both the skin and stopcock every 3.0 days for microbiological analysis including in 101 neurosurgical patient. Risk factors for positive event defined as either VRC or VRI were recorded and related to our microbiological findings. A total of 1261 CSF samples, 473 skin swabs, and 450 stopcock swabs were collected. Skin site was more frequently colonized than stopcock (70 (60%) vs 34 (29%), p = 0.023), and earlier (14 ±1.4 vs 24 ±1.5 days, p<0.0001). Sixty-one (52%) and 32 (27%) skin and stopcock sites were colonized with commensal bacteria, 1 (1%) and 1 (1%) with pathogens, 8 (7%) and 1 (1%) with combined pathogens and commensal bacteria, respectively. Sixteen positive events were diagnosed; a cutaneous origin was identified in 69% of cases. The presence of a pathogen at skin site (6/16 vs 4/85, OR: 11.8, [2.5–56.8], p = 0.002) and CSF leakage (7/16 vs 6/85, OR 10 [2.4–41.2], p = 0.001)) were the two independent significant risk factors statistically linked to positive events occurrence. Our results suggest that VRC and VRI mainly results from an extra-luminal progression of pathogens initially colonizing the skin site where CSF leaks. PMID:26555597
49 CFR 173.3 - Packaging and exceptions.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-unit tank car tanks. (1) A DOT 3A480 or DOT 3AA480 cylinder containing chlorine or sulphur dioxide that... containing chlorine or sulphur dioxide that has developed a leak in the valve or fusible plug may be... equipment; and (iii) Knowledge of the properties of chlorine and sulphur dioxide. (4) Packagings repaired...
77 FR 51546 - Federal Property Suitable as Facilities To Assist the Homeless
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-24
...., presence of asbestos, most recent use--office Minnesota Noyes Land Port of Entry SW Side of US Rte. 75... surroundings; remedial action has been taken for asbestos removal Missouri Long Branch Lake 30174 Visitor... extensive repairs; severe leaks around drains, asbestos identified District of Columbia West Heating Plant...
Extensive localized or pitting corrosion of copper pipes used in household drinking-water plumbing can eventually lead to pinhole water leaks that may result in water damage, mold growth, and costly repairs. A large water system in Florida has been addressing a widespread pinhole...
Extensive localized or pitting corrosion of copper pipes used in household drinking-water plumbing can eventually lead to pinhole water leaks that may result in water damage, mold growth, and costly repairs. A growing number of problems have been associated with high pH and low ...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-06
... million by volume (ppmv) total strippable hydrocarbons (as methane) in the stripping gas collected via the... methane) collected via the Modified El Paso Method. We are also proposing to include alternative leak.... The delay of repair action level would be either 62 ppmv total strippable hydrocarbons (as methane...
46 CFR 59.10-30 - Seal welding.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Seal welding. 59.10-30 Section 59.10-30 Shipping COAST... VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service § 59.10-30 Seal welding. Where leaks occur in riveted joints or connections, they shall be carefully investigated to...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-15
..., restaurants and other food service establishments. Cold storage includes the equipment used to store meat... equipment found in supermarkets, grocery and convenience stores, restaurants, and other food service... public comment on the selection of 24 hours as an appropriate amount of time, at a minimum, that must...
49 CFR 177.854 - Disabled vehicles and broken or leaking packages; repairs.
Code of Federal Regulations, 2010 CFR
2010-10-01
... vehicles other than cargo tank motor vehicles used for the transportation of Class 3 (flammable liquid) or... other than necessary traffic stops any motor vehicle transporting any hazardous material is stopped upon... shall be made to remove the motor vehicle to a place where the hazards of the materials being...
46 CFR 59.10-30 - Seal welding.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Seal welding. 59.10-30 Section 59.10-30 Shipping COAST... VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service § 59.10-30 Seal welding. Where leaks occur in riveted joints or connections, they shall be carefully investigated to...
46 CFR 59.10-30 - Seal welding.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Seal welding. 59.10-30 Section 59.10-30 Shipping COAST... VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service § 59.10-30 Seal welding. Where leaks occur in riveted joints or connections, they shall be carefully investigated to...
46 CFR 59.10-30 - Seal welding.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Seal welding. 59.10-30 Section 59.10-30 Shipping COAST... VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service § 59.10-30 Seal welding. Where leaks occur in riveted joints or connections, they shall be carefully investigated to...
40 CFR Table 7 to Subpart Eeee of... - Initial Compliance With Work Practice Standards
Code of Federal Regulations, 2011 CFR
2011-07-01
... equivalent control that meets the requirements in Table 4 to this subpart, item 1.a i. After emptying and... out a leak detection and repair program or equivalent control according to one of the subparts listed... CATEGORIES National Emission Standards for Hazardous Air Pollutants: Organic Liquids Distribution (Non...
40 CFR Table 7 to Subpart Eeee of... - Initial Compliance With Work Practice Standards
Code of Federal Regulations, 2010 CFR
2010-07-01
... equivalent control that meets the requirements in Table 4 to this subpart, item 1.a i. After emptying and... out a leak detection and repair program or equivalent control according to one of the subparts listed... CATEGORIES National Emission Standards for Hazardous Air Pollutants: Organic Liquids Distribution (Non...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-28
... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No. PHMSA-2013-0185] Pipeline Safety: Notice to Operators of Hazardous Liquid and Natural Gas Pipelines of a Recall on Leak Repair Clamps Due to Defective Seal AGENCY: Pipeline and Hazardous Materials Safety...
Use of radiometer to reform and repair an old living house to passive solar one
NASA Astrophysics Data System (ADS)
Okamoto, Yoshizo; Inagaki, Terumi; Suzuki, Takakazu; Kurokawa, Takashi
1994-03-01
Japanese living houses mainly consist of wooden elements in high-temperature and moist conditions. To modify the hot and humid environment, a conventional old house was partially rebuilt and repaired. Especially in the winter season, a diagnostic thermographic test was used to find deteriorated and leaking parts of interior and exterior walls. Macroscopic deteriorated parts were checked again in detail. The deteriorated element was then removed. During the reconstruction process, a new solar heat and air conditioning system using a silica-gel adsorber and underground water was installed to cool and warm up the living room. Thermography tests of this remodeled house show that room temperature is always constant and mild to human beings, especially in the winter. Temperature and heat flow distribution of flowing air in the living room was measured using thermal net and wire methods. Leaking thermal streak flow of the gap was locally visualized by the IR radiometer and a highly sensitive video camera. It was verified that IR thermography is a useful measuring instrument to check thermal defects of a house.
Management of an infected aortic graft with endovascular stent grafting.
Jamel, Sara; Attia, Rizwan; Young, Christopher
2013-01-01
Aortic graft infection, one of the most common fatal complications of aortovascular surgery, is managed mainly by the removal of infected graft material and re-establishment of vascular continuity using an extra-anatomical bypass or in situ graft replacement. Despite significant progress in perioperative, surgical, and medical treatments, the mortality and morbidity for this condition remain high. Here, we report the use of endograft implantation and prolonged intravenous antibiotics to successfully treat a life-threatening Dacron aortic tube graft infection and anastomotic leak. Although the gold standard is surgical removal of infected material and repair with a homograft, in certain extremely high-risk patients such as ours, an alternate strategy may be warranted when the risks associated with surgery are prohibitive. Endovascular repair of a surgical Dacron graft leak may provide a novel temporizing measure in the acute setting, allowing for delayed semi-urgent surgical intervention, or it may provide a definitive treatment, as in our case. At the four-year follow-up, our patient was well with a good quality of life and with no clinical, radiological, or biochemical evidence of infection.
Jeevan, Dhruve S; Ormond, D Ryan; Kim, Ana H; Meiteles, Lawrence Z; Stidham, Katrina R; Linstrom, Christopher; Murali, Raj
2015-04-01
Temporal bone encephalocele has become less common as the incidence of chronic mastoid infection and surgery for this condition has decreased. As a result, the diagnosis is often delayed, and the encephalocele is often an incidental finding. This situation can result in serious neurologic complications with patients presenting with cerebrospinal fluid leak and meningitis. We review the occurrence of, characteristics of, and repair experience with temporal encephaloceles from 2000-2012. We conducted a retrospective review of 32 patients undergoing combined mastoidectomy and middle cranial fossa craniotomy for the treatment of temporal encephalocele. The diagnosis of temporal encephalocele was made in all patients using high-resolution temporal bone computed tomography and magnetic resonance imaging. At the time of diagnosis, 12 patients had confirmed cerebrospinal fluid leak; other common presenting symptoms included hearing loss and ear fullness. Tegmen defect was most commonly due to chronic otitis media (n = 14). Of these patients, 8 had undergone prior mastoidectomy, suggesting an iatrogenic cause. Other etiologies included radiation exposure, congenital defects, and spontaneous defects. Additionally, 2 patients presented with meningitis; 1 patient had serious neurologic deficits resulting from venous infarction. The risk of severe neurologic complications after the herniation of intracranial contents through a tegmen defect necessitates prompt recognition and appropriate management. Computed tomography and magnetic resonance imaging aid in definitive diagnosis. A combined mastoid/middle fossa approach allows for sustainable repair with adequate exposure of defects and support of intracranial contents. Copyright © 2015 Elsevier Inc. All rights reserved.
Tatebe, Leah Carey; Jennings, Andrew; Tatebe, Ken; Handy, Alexandra; Prajapati, Purvi; Smith, Michael; Do, Tai; Ogola, Gerald O; Gandhi, Rajesh R; Duane, Therese M; Luk, Stephen; Petrey, Laura Bruce
2017-04-01
Delayed colonic anastomosis after damage control laparotomy (DCL) is an alternative to colostomies during a single laparotomy (SL) in high-risk patients. However, literature suggests increased colonic leak rates up to 27% with DCL, and various reported risk factors. We evaluated our regional experience to determine if delayed colonic anastomosis was associated with worse outcomes. A multicenter retrospective cohort study was performed across three Level I trauma centers encompassing traumatic colon injuries from January 2006 through June 2014. Patients with rectal injuries or mortality within 24 hours were excluded. Patient and injury characteristics, complications, and interventions were compared between SL and DCL groups. Regional readmission data were utilized to capture complications within 6 months of index trauma. Of 267 patients, 69% had penetrating injuries, 21% underwent DCL, and the mortality rate was 4.9%. Overall, 176 received primary repair (26 in DCL), 90 had resection and anastomosis (28 in DCL), and 26 had a stoma created (10 end colostomies and 2 loop ileostomies in DCL). Thirty-five of 56 DCL patients had definitive colonic repair subsequent to their index operation. DCL patients were more likely to be hypotensive; require more resuscitation; and suffer acute kidney injury, pneumonia, adult respiratory distress syndrome, and death. Five enteric leaks (1.9%) and three enterocutaneous fistulas (ECF, 1.1%) were identified, proportionately distributed between DCL and SL (p = 1.00, p = 0.51). No difference was seen in intraperitoneal abscesses (p = 0.13) or surgical site infections (SSI, p = 0.70) between cohorts. Among SL patients, pancreas injuries portended an increased risk of intraperitoneal abscesses (p = 0.0002), as did liver injuries in DCL patients (p = 0.06). DCL was not associated with increased enteric leaks, ECF, SSI, or intraperitoneal abscesses despite nearly two-thirds having delayed repair. Despite this being a multicenter study, it is underpowered, and a prospective trial would better demonstrate risks of DCL in colon trauma. Therapeutic study, level IV.
Changes in Oxidative Damage, Inflammation and [NAD(H)] with Age in Cerebrospinal Fluid
Guest, Jade; Grant, Ross; Mori, Trevor A.; Croft, Kevin D.
2014-01-01
An extensive body of evidence indicates that oxidative stress and inflammation play a central role in the degenerative changes of systemic tissues in aging. However a comparatively limited amount of data is available to verify whether these processes also contribute to normal aging within the brain. High levels of oxidative damage results in key cellular changes including a reduction in available nicotinamide adenine dinucleotide (NAD+), an essential molecule required for a number of vital cellular processes including DNA repair, immune signaling and epigenetic processing. In this study we quantified changes in [NAD(H)] and markers of inflammation and oxidative damage (F2-isoprostanes, 8-OHdG, total antioxidant capacity) in the cerebrospinal fluid (CSF) of healthy humans across a wide age range (24–91 years). CSF was collected from consenting patients who required a spinal tap for the administration of anesthetic. CSF of participants aged >45 years was found to contain increased levels of lipid peroxidation (F2-isoprostanes) (p = 0.04) and inflammation (IL-6) (p = 0.00) and decreased levels of both total antioxidant capacity (p = 0.00) and NAD(H) (p = 0.05), compared to their younger counterparts. A positive association was also observed between plasma [NAD(H)] and CSF NAD(H) levels (p = 0.03). Further analysis of the data identified a relationship between alcohol intake and CSF [NAD(H)] and markers of inflammation. The CSF of participants who consumed >1 standard drink of alcohol per day contained lower levels of NAD(H) compared to those who consumed no alcohol (p<0.05). An increase in CSF IL-6 was observed in participants who reported drinking >0–1 (p<0.05) and >1 (p<0.05) standard alcoholic drinks per day compared to those who did not drink alcohol. Taken together these data suggest a progressive age associated increase in oxidative damage, inflammation and reduced [NAD(H)] in the brain which may be exacerbated by alcohol intake. PMID:24454842
NASA Astrophysics Data System (ADS)
Roda-Stuart, D. J.; Ravikumar, A. P.; Brandt, A. R.
2017-12-01
Upstream production sites contribute 66 percent of methane emissions from natural gas systems [1]. Being a major greenhouse gas, many states and national governments are developing policies to reduce methane emissions. Recent policies to address this issue have focused on periodic leak detection and repair (LDAR) surveys at oil and gas facilities [2]. Development of effective LDAR surveys is complicated by two things. First, available empirical data makes it difficult to say anything definitive about which facilities or equipment are most prone to leakage. Second, there has been little research done on post-LDAR emissions profiles and the time evolution of leaks, two measures that would influence survey effectiveness and cost. In this work, we present data from LDAR operations conducted at upstream facilities of a Canadian natural gas producer. Surveys were done by an outside contractor using a FLIR optical gas imaging camera. Twenty-two well pads, five processing plants, and three compressor stations were surveyed, of which four, two, and one, respectively, were revisited. We examine the persistence of leaks over time periods ranging from 6 months to 15 months following the initial LDAR survey. Developing pre- and post-survey emission factors and distributions can help inform survey schedules and help update and monitor mitigation targets. Furthermore, we analyze the effect of weather conditions, survey frequency, and operational characteristics of equipment on the effectiveness of the LDAR program. For instance, we find that a survey done at the commissioning of a gas processing plant yields both safety and emissions reduction benefits. Using leak frequency distributions, we identify components and equipment that require more frequent and targeted surveying. Insights from this study can assist businesses and policy makers develop methane mitigation policies aimed at maximizing the marginal benefits of LDAR programs. [1] Inventory of U.S. Greenhouse Gas Emissions and Sinks: 1990-2015. US Environmental Protection Agency, 2017. [2] New Source Performance Standards; Oil and Natural Gas Sector: Emission Standards for New, Reconstructed, and Modified Sources. Federal Register, 81(107):35824-35942, 2016.
2006-01-26
KENNEDY SPACE CENTER, FLA. - At Cape Canaveral Air Force Station, workers help place the lamp room detached from the Cape Canaveral Lighthouse onto a flat bed truck. It will be moved to a facility near Cape Canaveral for repairs and renovation. Leaks in the roof allowed moisture to seep in. The lamp room is being removed for repairs and refurbishment. In addition, the original brass roof will be restored and put back in place. The Cape Canaveral Lighthouse is the only operational lighthouse owned by the Air Force. It was first erected in 1868 near the edge of the Atlantic Ocean. Photo credit: NASA/Jack Pfaller
2006-01-26
KENNEDY SPACE CENTER, FLA. - At Cape Canaveral Air Force Station, workers secure the lamp room detached from the Cape Canaveral Lighthouse onto a flat bed truck. Leaks in the roof allowed moisture to seep in. The lamp room will be moved to a facility near Cape Canaveral for repairs and renovation. The lamp room is being removed for repairs and refurbishment. In addition, the original brass roof will be restored and put back in place. The Cape Canaveral Lighthouse is the only operational lighthouse owned by the Air Force. It was first erected in 1868 near the edge of the Atlantic Ocean. Photo credit: NASA/Jack Pfaller
Porhomayon, Jahan; Zadeii, Gino; Yarahamadi, Alireza; Nader, Nader D.
2013-01-01
The developments of new spinal needles and needle tip designs have reduced the incidence of postdural puncture headache (PDPH). Although it is clear that reducing the loss of CSF leak from dural puncture reduces the headache, there are areas regarding the pathogenesis, treatment, and prevention of PDPH that remain controversial. Air travel by itself may impose physiological alteration in central nervous system that may be detrimental to patients with PDPH. This case report highlights a case of a young female patient who suffered from a severe incapacitating PDPH headache during high-altitude flight with a commercial jet. PMID:23401803
Intracochlear drug injections through the round window membrane: Measures to improve drug retention
Plontke, Stefan K.; Hartsock, Jared J.; Gill, Ruth M.; Salt, Alec N.
2016-01-01
The goal of this study was to develop appropriate methodology to apply drugs quantitatively to perilymph of the ear. Intratympanic applications of drugs to the inner ear often result in variable drug levels in perilymph and can only be used for molecules that readily permeate the round window (RW) membrane. Direct intracochlear and intralabyrinthine application procedures for drugs, genes or cell-based therapies by-pass the tight boundaries at the round window, oval window, otic capsule and the blood-labyrinth barrier. However, perforations can release inner ear pressure, allowing cerebrospinal fluid to enter through the cochlear aqueduct, displacing the injected drug solution into the middle ear. Two markers, fluorescein or fluorescein isothiocyanate (FITC)-labeled dextran, were used to quantify how much of an injected substance was retained in cochlear perilymph following an intracochlear injection. We evaluated whether procedures to mitigate fluid leaks improved marker retention in perilymph. Almost all procedures to reduce volume efflux, including the use of gel for internal sealing and glue for external sealing of the injection site, resulted in improved retention of the marker in perilymph. Adhesive on the RW membrane effectively prevented leaks but also influenced fluid exchange between CSF and perilymph. We conclude that drugs can be delivered to the ear in a consistent, quantitative manner using intracochlear injections if care is taken to control the fluid leaks that result from cochlear perforation. PMID:26905306
Management of Anterior Skull Base Defect Depending on Its Size and Location
Bernal-Sprekelsen, Manuel; Rioja, Elena; Enseñat, Joaquim; Enriquez, Karla; Viscovich, Liza; Agredo-Lemos, Freddy Enrique; Alobid, Isam
2014-01-01
Introduction. We present our experience in the reconstruction of these leaks depending on their size and location. Material and Methods. Fifty-four patients who underwent advanced skull base surgery (large defects, >20 mm) and 62 patients with CSF leaks of different origin (small, 2–10 mm, and midsize, 11–20 mm, defects) were included in the retrospective study. Large defects were reconstructed with a nasoseptal pedicled flap positioned on fat and fascia lata. In small and midsized leaks. Fascia lata in an underlay position was used for its reconstruction covered with mucoperiosteum of either the middle or the inferior turbinate. Results. The most frequent etiology for small and midsized defects was spontaneous (48.4%), followed by trauma (24.2%), iatrogenic (5%). The success rate after the first surgical reconstruction was 91% and 98% in large skull base defects and small/midsized, respectively. Rescue surgery achieved 100%. Conclusions. Endoscopic surgery for any type of skull base defect is the gold standard. The size of the defects does not seem to play a significant role in the success rate. Fascia lata and mucoperiosteum of the turbinate allow a two-layer reconstruction of small and midsized defects. For larger skull base defects, a combination of fat, fascia lata, and nasoseptal pedicled flaps provides a successful reconstruction. PMID:24895567
Recent evaluations of crack-opening-area in circumferentially cracked pipes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahman, S.; Brust, F.; Ghadiali, N.
1997-04-01
Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. The leak rates depend on the crack-opening area of the through-wall crack in the pipe. In addition to LBB analyses which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessingmore » temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section XI. The objectives of this study were to review, evaluate, and refine current predictive models for performing crack-opening-area analyses of circumferentially cracked pipes. The results from twenty-five full-scale pipe fracture experiments, conducted in the Degraded Piping Program, the International Piping Integrity Research Group Program, and the Short Cracks in Piping and Piping Welds Program, were used to verify the analytical models. Standard statistical analyses were performed to assess used to verify the analytical models. Standard statistical analyses were performed to assess quantitatively the accuracy of the predictive models. The evaluation also involved finite element analyses for determining the crack-opening profile often needed to perform leak-rate calculations.« less
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, a worker examines the location of the quick disconnect on the Ground Umbilical Carrier Plate, or GUCP, being removed from space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers prepare to remove the ground umbilical carrier plate (GUCP) from space shuttle Discovery's external fuel tank. A hydrogen gas leak at that location during tanking for Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2010-11-10
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers remove the seal from the ground umbilical carrier plate (GUCP). A hydrogen gas leak at that location on the external fuel tank during tanking for space shuttle Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Jack Pfaller
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, a worker has removed the seal from the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers install a cap over the hole in space shuttle Discovery's external fuel tank where the ground umbilical carrier plate (GUCP) was removed. A hydrogen gas leak at that location during tanking for Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers begin to remove the ground umbilical carrier plate (GUCP) from space shuttle Discovery's external fuel tank. A hydrogen gas leak at that location during tanking for Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers prepare to remove the 7-inch quick disconnect on the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers remove the 7-inch quick disconnect on the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, the ground umbilical carrier plate (GUCP) is ready to be examined. A hydrogen gas leak at that location on the external fuel tank during tanking for space shuttle Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2010-11-10
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers examine the seal from the ground umbilical carrier plate (GUCP). A hydrogen gas leak at that location on the external fuel tank during tanking for space shuttle Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Jack Pfaller
2010-11-10
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers begin to remove the seal from the ground umbilical carrier plate (GUCP). A hydrogen gas leak at that location on the external fuel tank during tanking for space shuttle Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Jack Pfaller
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers remove the 7-inch quick disconnect on the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers move the ground umbilical carrier plate (GUCP) to a location where it can be examined. A hydrogen gas leak at that location on the external fuel tank during tanking for space shuttle Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers remove the 7-inch quick disconnect on the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers install a cap over the hole in space shuttle Discovery's external fuel tank where the ground umbilical carrier plate (GUCP) was removed. A hydrogen gas leak at that location during tanking for Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2010-11-11
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers prepare to remove the ground umbilical carrier plate (GUCP) from space shuttle Discovery's external fuel tank. A hydrogen gas leak at that location during tanking for Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Dimitri Gerondidakis
2010-11-10
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers examine the seal from the ground umbilical carrier plate (GUCP). A hydrogen gas leak at that location on the external fuel tank during tanking for space shuttle Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Jack Pfaller
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, a worker has removed the seal from the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, a worker removes the seal from the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers remove the 7-inch quick disconnect from the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, a worker has removed the 7-inch quick disconnect from the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
2009-06-24
CAPE CANAVERAL, Fla. – On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers prepare to remove the seal from the Ground Umbilical Carrier Plate, or GUCP, on space shuttle Endeavour's external fuel tank. A hydrogen leak at the location during tanking for the STS-127 mission caused the launch attempts to be scrubbed on June 13 and June 17. The GUCP will be examined to determine the cause of the hydrogen leak and repaired. The GUCP is the overboard vent to the pad and the flame stack where the vented hydrogen is burned off. Endeavour's next launch attempt is targeted for July 11 at 7:39 p.m. EDT. Photo credit: NASA/Jack Pfaller
Space Shuttle RCS Oxidizer Leak Repair for STS-26
NASA Technical Reports Server (NTRS)
Delventhal, R. A.; Faget, N. M.
1989-01-01
Following propellant loading of the Space Shuttle's reaction control system (RCS) for mission STS 26, an oxidizer leak was detected in the left orbital maneuvering system (OMS) pod, where the RCS is located. Subsequent investigation determined that the leak was isolated at a mechanical Dynatube fitting near the RCS nitrogen tetroxide tank. An intense effort was initiated to design, fabricate, and qualify a sealing device to stop the oxidizer leak externally so that the Space Shuttle launch could proceed. It was discovered that sealing devices called clamshells were widely used throughout the petrochemical and power generation industries to stop leaks developed in large diameter pipes which carry steam or other hazardous fluids. These clamshells are available in different diameters and strengths and are placed around the pipe at the location of the leak. A sealing compound is then injected under high pressure into the clamshell to stop the leak. This technology was scaled down and applied to the problem of stopping the leak on the Orbiter, which was on a half-inch diameter line in a nearly inaccessible location. Many obstacles had to be overcome such as determining that the sealing material would be compatible with the nitrogen tetroxide and ensuring that the clamshell would actually fit around the Dynatube fitting without interfering with other lines which were in close proximity. The effort at the NASA Johnson Space Center included materials compatibility testing of several sealants, design of a clamshell to fit in the confined compartment, and manufacture and qualification of the flight hardware. A clamshell was successfully placed around the Dynatube fitting on the Orbiter and the oxidizer leak was terminated. Then it was decided to apply this technology further and design clamshells for other mechanical fittings onboard the Orbiter and develop sealing compounds which will be compatible with fuels such as monomethyl hydrazine (MMH). The potential exists for using this type of sealing device in numerous other applications throughout the aerospace industry.
40 CFR 264.1065 - Reporting requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... identification number of each pump for which a leak was not repaired as required in § 264.1052 (c) and (d)(6... control device installed as required by § 264.1052, 264.1053, 264.1054, or 264.1055 exceeded or operated outside of the design specifications as defined in § 264.1064(e) and as indicated by the control device...
40 CFR 264.1065 - Reporting requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... identification number of each pump for which a leak was not repaired as required in § 264.1052 (c) and (d)(6... control device installed as required by § 264.1052, 264.1053, 264.1054, or 264.1055 exceeded or operated outside of the design specifications as defined in § 264.1064(e) and as indicated by the control device...
40 CFR 264.1065 - Reporting requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... identification number of each pump for which a leak was not repaired as required in § 264.1052 (c) and (d)(6... control device installed as required by § 264.1052, 264.1053, 264.1054, or 264.1055 exceeded or operated outside of the design specifications as defined in § 264.1064(e) and as indicated by the control device...
40 CFR 264.1065 - Reporting requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... identification number of each pump for which a leak was not repaired as required in § 264.1052 (c) and (d)(6... control device installed as required by § 264.1052, 264.1053, 264.1054, or 264.1055 exceeded or operated outside of the design specifications as defined in § 264.1064(e) and as indicated by the control device...
40 CFR 264.1065 - Reporting requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... identification number of each pump for which a leak was not repaired as required in § 264.1052 (c) and (d)(6... control device installed as required by § 264.1052, 264.1053, 264.1054, or 264.1055 exceeded or operated outside of the design specifications as defined in § 264.1064(e) and as indicated by the control device...
46 CFR 59.10-30 - Seal welding.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Seal welding. 59.10-30 Section 59.10-30 Shipping COAST... VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service § 59.10-30 Seal... determine the cause. Such leaks may be made tight by seal welding the edge, if, in the opinion of the...
40 CFR Table 10 to Subpart Eeee of... - Continuous Compliance With Work Practice Standards
Code of Federal Regulations, 2010 CFR
2010-07-01
... liquids, operate a vapor balancing system. i. Monitoring each potential source of vapor leakage in the... requirements of 40 CFR part 63, subpart TT, UU, or H. i. Carrying out a leak detection and repair program in... relief devices, monitoring each potential source of vapor leakage in the system, including, but not...
49 CFR 180.211 - Repair, rebuilding and reheat treatment of DOT-4 series specification cylinders.
Code of Federal Regulations, 2011 CFR
2011-10-01
... insulation jacket to permit access to the cylinder, piping system, or neck tube. (ii) The replacement of the... insulation space is authorized. The replacement material must be equivalent to that used at the time of... cylinder was originally manufactured; (ii) Leak tested before and after assembly of the insulation jacket...
49 CFR 180.211 - Repair, rebuilding and reheat treatment of DOT-4 series specification cylinders.
Code of Federal Regulations, 2014 CFR
2014-10-01
... insulation jacket to permit access to the cylinder, piping system, or neck tube. (ii) The replacement of the... insulation space is authorized. The replacement material must be equivalent to that used at the time of... cylinder was originally manufactured; (ii) Leak tested before and after assembly of the insulation jacket...
49 CFR 180.211 - Repair, rebuilding and reheat treatment of DOT-4 series specification cylinders.
Code of Federal Regulations, 2012 CFR
2012-10-01
... insulation jacket to permit access to the cylinder, piping system, or neck tube. (ii) The replacement of the... insulation space is authorized. The replacement material must be equivalent to that used at the time of... cylinder was originally manufactured; (ii) Leak tested before and after assembly of the insulation jacket...
49 CFR 180.211 - Repair, rebuilding and reheat treatment of DOT-4 series specification cylinders.
Code of Federal Regulations, 2013 CFR
2013-10-01
... insulation jacket to permit access to the cylinder, piping system, or neck tube. (ii) The replacement of the... insulation space is authorized. The replacement material must be equivalent to that used at the time of... cylinder was originally manufactured; (ii) Leak tested before and after assembly of the insulation jacket...
ERIC Educational Resources Information Center
Shah, Lisa; Hao, Jie; Schneider, Jeremy; Fallin, Rebekah; Cortes, Kimberly Linenberger; Ray, Herman E.; Rushton, Gregory T.
2018-01-01
Teachers play a critical role in the preparation of future science, technology, engineering, and mathematics majors and professionals. What teachers know about their discipline (i.e., content knowledge) has been identified as an important aspect of instructional effectiveness; however, studies have not yet assessed the content knowledge of…
2002-11-15
KENNEDY SPACE CENTER, FLA. -- Robotic arm experts get ready for ultrasound testing on Endeavour's robotic arm. A scrape of the honeycomb shell around the arm occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
2002-11-15
KENNEDY SPACE CENTER, FLA. -- Robotic arm experts get ready for ultrasound testing on Endeavour's robotic arm. A scrape of the honeycomb shell around the arm occurred while work platforms were being installed to gain access to repair the oxygen leak in the Shuttle's mid-body. Launch of Endeavour on mission STS-113 has been postponed until no earlier than Nov. 22.
Weld Repair of a Stamped Pressure Vessel in a Radiologically Controlled Zone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cannell, Gary L.; Huth, Ralph J.; Hallum, Randall T.
2013-08-26
In September 2012 an ASME B&PVC Section VIII stamped pressure vessel located at the DOE Hanford Site Effluent Treatment Facility (ETF) developed a through-wall leak. The vessel, a steam/brine heat exchanger, operated in a radiologically controlled zone (by the CH2MHill PRC or CHPRC), had been in service for approximately 17 years. The heat exchanger is part of a single train evaporator process and its failure caused the entire system to be shut down, significantly impacting facility operations. This paper describes the activities associated with failure characterization, technical decision making/planning for repair by welding, logistical challenges associated with performing work inmore » a radiologically controlled zone, performing the repair, and administrative considerations related to ASME code requirements.« less
Mathew, Esha; Collins, Meredith A; Fernandez-Barrena, Maite G; Holtz, Alexander M; Yan, Wei; Hogan, James O; Tata, Zachary; Allen, Benjamin L; Fernandez-Zapico, Martin E; di Magliano, Marina Pasca
2014-10-03
Pancreatic cancer, one of the deadliest human malignancies, is almost uniformly associated with a mutant, constitutively active form of the oncogene Kras. Studies in genetically engineered mouse models have defined a requirement for oncogenic KRAS in both the formation of pancreatic intraepithelial neoplasias, the most common precursor lesions to pancreatic cancer, and in the maintenance and progression of these lesions. Previous work using an inducible model allowing tissue-specific and reversible expression of oncogenic Kras in the pancreas indicates that inactivation of this GTPase at the pancreatic intraepithelial neoplasia stage promotes pancreatic tissue repair. Here, we extend these findings to identify GLI1, a transcriptional effector of the Hedgehog pathway, as a central player in pancreatic tissue repair upon Kras inactivation. Deletion of a single allele of Gli1 results in improper stromal remodeling and perdurance of the inflammatory infiltrate characteristic of pancreatic tumorigenesis. Strikingly, this partial loss of Gli1 affects activated fibroblasts in the pancreas and the recruitment of immune cells that are vital for tissue recovery. Analysis of the mechanism using expression and chromatin immunoprecipitation assays identified a subset of cytokines, including IL-6, mIL-8, Mcp-1, and M-csf (Csf1), as direct GLI1 target genes potentially mediating this phenomenon. Finally, we demonstrate that canonical Hedgehog signaling, a known regulator of Gli1 activity, is required for pancreas recovery. Collectively, these data delineate a new pathway controlling tissue repair and highlight the importance of GLI1 in regulation of the pancreatic microenvironment during this cellular process. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.
Hanford Double-Shell Tank Extent-of-Condition Review - 15498
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, J. M.; Baide, D. D.; Barnes, T. J.
2014-11-19
During routine visual inspections of Hanford double-shell waste tank 241-AY-102 (AY-102), anomalies were identified on the annulus floor which resulted in further evaluations. Following a formal leak assessment in October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of AY-102 was leaking. A formal leak assessment, documented in RPP-ASMT-53793, Tank 241-AY-102 Leak Assessment Report, identified first-of-a-kind construction difficulties and trial-and-error repairs as major contributing factors to tank failure.1 To determine if improvements in double-shell tank (DST) construction occurred after construction of tank AY-102, a detailed review and evaluation of historical construction records was performed for Hanford’smore » remaining twenty-seven DSTs. Review involved research of 241 boxes of historical project documentation to better understand the condition of the Hanford DST farms, noting similarities in construction difficulties/issues to tank AY-102. Information gathered provides valuable insight regarding construction difficulties, future tank operations decisions, and guidance of the current tank inspection program. Should new waste storage tanks be constructed in the future, these reviews also provide valuable lessons-learned.« less
Aerial surveillance for gas and liquid hydrocarbon pipelines using a flame ionization detector (FID)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riquetti, P.V.; Fletcher, J.I.; Minty, C.D.
1996-12-31
A novel application for the detection of airborne hydrocarbons has been successfully developed by means of a highly sensitive, fast responding Flame Ionization Detector (FID). The traditional way to monitor pipeline leaks has been by ground crews using specific sensors or by airborne crews highly trained to observe anomalies associated with leaks during periodic surveys of the pipeline right-of-way. The goal has been to detect leaks in a fast and cost effective way before the associated spill becomes a costly and hazardous problem. This paper describes a leak detection system combined with a global positioning system (GPS) and a computerizedmore » data output designed to pinpoint the presence of hydrocarbons in the air space of the pipeline`s right of way. Fixed wing aircraft as well as helicopters have been successfully used as airborne platforms. Natural gas, crude oil and finished products pipelines in Canada and the US have been surveyed using this technology with excellent correlation between the aircraft detection and in situ ground detection. The information obtained is processed with a proprietary software and reduced to simple coordinates. Results are transferred to ground crews to effect the necessary repairs.« less
Aberrant wound-healing response in mitomycin C-treated leaking blebs: a histopathologic study.
Elner, Victor M; Newman-Casey, Paula Anne; Patil, A Jayaprakash; Flint, Andrew; Biswas, Jyotirmay; Moroi, Sayoko E; Pushparaj, Vaijayanthi; Edward, Deepak P
2009-08-01
To characterize histopathologic features of leaking mitomycin C-treated blebs and aberrant wound healing that may lead to persistent conjunctival thinning and leakage. Forty mitomycin C-treated filtering blebs excised for persistent leaks from 40 patients were examined histopathologically using hematoxylin-eosin, periodic acid-Schiff, Masson trichrome, and Alcian blue histochemical stains. Ninety percent of the leaking blebs contained epithelial-stromal domes with areas of acellular stroma covered by attenuated epithelium. Seventy-five percent of the blebs demonstrated varying degrees of fibrovascular repair growing from the bleb margin, either beneath or interdigitating with the acellular zone. A novel observation in 65% of specimens was Alcian blue-positive myxoid stroma at the interface between the fibrovascular proliferation and the epithelial-stromal dome. The association between the presence of fibrovascular proliferation and Alcian blue-staining myxoid stroma was significant by Fisher exact test (P = .002). A desirable filtration bleb requires a sufficient reparative fibrovascular response to maintain an epithelial-stromal barrier to prevent leakage. Fibroblasts must lay down a continuous collagen-rich fibrous layer, rather than merely myxoid stroma, beneath the conjunctival epithelium to promote bleb stability. Surgical techniques and postsurgical care should aim to attain this desired outcome.
Prospective evaluation of biodegradable polymeric sealant for intraoperative air leaks.
Park, Bernard J; Snider, John M; Bates, Nathan R; Cassivi, Stephen D; Jett, G Kimble; Sonett, Joshua R; Toloza, Eric M
2016-12-12
A biodegradable polymeric sealant has been previously shown to reduce postoperative air leaks after open pulmonary resection. The aim of this study was to evaluate safety and efficacy during minimally invasive pulmonary resection. In a multicenter prospective single-arm trial, 112 patients with a median age of 69 years (range 34-87 years) were treated with sealant for at least one intraoperative air leak after standard methods of repair (sutures, staples or cautery) following minimally invasive pulmonary resection (Video-Assisted Thoracic Surgery (VATS) or Robotic-Assisted). Patients were followed in hospital and 1 month after surgery for procedure-related and device-related complications and presence of air leak. Forty patients had VATS and 72 patients had Robotic-Assisted procedures with the majority (80/112, 71%) undergoing anatomic resection (61 lobectomy, 13 segmentectomy, 6 bilobectomy). There were no device-related adverse events. The overall morbidity rate was 41% (46/112), with major complications occurring in 16.1% (18/112). In-hospital mortality and 30-day mortality were 1.9% (2/103). The majority of intraoperative air leaks (107/133, 81%) were sealed after sealant application, and an additional 16% (21/133) were considered reduced. Forty-nine percent of patients (55/112) were free of air leak throughout the entire postoperative study period. Median chest tube duration was 2 days (range 1 - 46 days), and median length of hospitalization was 3 days (range 1 - 20 days). This study demonstrated that use of a biodegradable polymer for closure of intraoperative air leaks as an adjunct to standard methods is safe and effective following minimally invasive pulmonary resection. ClinicalTrials.gov: NCT01867658 . Registered 3 May 2013.
NASA Astrophysics Data System (ADS)
Williams, David J.; Wadsworth, Winthrop; Salvaggio, Carl; Messinger, David W.
2006-08-01
Undiscovered gas leaks, known as fugitive emissions, in chemical plants and refinery operations can impact regional air quality and present a loss of product for industry. Surveying a facility for potential gas leaks can be a daunting task. Industrial leak detection and repair programs can be expensive to administer. An efficient, accurate and cost effective method for detecting and quantifying gas leaks would both save industries money by identifying production losses and improve regional air quality. Specialized thermal video systems have proven effective in rapidly locating gas leaks. These systems, however, do not have the spectral resolution for compound identification. Passive FTIR spectrometers can be used for gas compound identification, but using these systems for facility surveys is problematic due to their small field of view. A hybrid approach has been developed that utilizes the thermal video system to locate gas plumes using real time visualization of the leaks, coupled with the high spectral resolution FTIR spectrometer for compound identification and quantification. The prototype hybrid video/spectrometer system uses a sterling cooled thermal camera, operating in the MWIR (3-5 μm) with an additional notch filter set at around 3.4 μm, which allows for the visualization of gas compounds that absorb in this narrow spectral range, such as alkane hydrocarbons. This camera is positioned alongside of a portable, high speed passive FTIR spectrometer, which has a spectral range of 2 - 25 μm and operates at 4 cm -1 resolution. This system uses a 10 cm telescope foreoptic with an onboard blackbody for calibration. The two units are optically aligned using a turning mirror on the spectrometer's telescope with the video camera's output.
Next-generation confirmatory disease diagnostics
NASA Astrophysics Data System (ADS)
Lin, Robert; Gerver, Rachel; Karns, Kelly; Apori, Akwasi A.; Denisin, Aleksandra K.; Herr, Amy E.
2014-06-01
Microfluidic tools are advancing capabilities in screening diagnostics for use in near-patient settings. Here, we review three case studies to illustrate the flexibility and analytical power offered by microanalytical tools. We first overview a near-patient tool for detection of protein markers found in cerebrospinal fluid (CSF), as a means to identify the presence of cerebrospinal fluid in nasal mucous - an indication that CSF is leaking into the nasal cavity. Microfluidic design allowed integration of several up-stream preparatory steps and rapid, specific completion of the human CSF protein assay. Second, we overview a tear fluid based assay for lactoferrin, a protein produced in the lacrimal gland, then secreted into tear fluid. Tear Lf is a putative biomarker for primary SS. A critical contribution of this and related work being measurement of Lf, even in light of well-known and significant matrix interactions and losses during the tear fluid collection and preparation. Lastly, we review a microfluidic barcode platform that enables rapid measurement of multiple infectious disease biomarkers in human sera. The assay presents a new approach to multiplexed biomarker detection, yet in a simple straight microchannel - thus providing a streamlined, simplified microanalytical platform, as is relevant to robust operation in diagnostic settings. We view microfluidic design and analytical chemistry as the basis for emerging, sophisticated assays that will advance not just screening diagnostic technology, but confirmatory assays, sample preparation and handling, and thus introduction and utilization of new biomarkers and assay formats.
Evaluation of posttraumatic recurrent bacterial meningitis in adults.
Deveci, Özcan; Uysal, Cem; Varol, Sefer; Tekin, Recep; Bozkurt, Fatma; Bekçibaşı, Muhammed; Hoşoğlu, Salih
2015-07-01
Acute bacterial meningitis may develop as a complication after head trauma. The aim of this study was to present the demographic, clinical, microbiological and radiological characteristics of adult patients who presented with recurrent bacterial meningitis attacks after trauma. Using a retrospective approach, the medical records of patients with acute recurrent bacterial meningitis (RBM) were reviewed, and those who had a history of trauma were included into the study. RBM was diagnosed based on clinical, bacteriologic and laboratory results. Demographic characteristics, clinical course, laboratory test results including cerebrospinal fluid analysis (CSF), radiological images, and the applied treatments were evaluated. A total of two hundred and twelve patients with acute bacterial meningitis were included into the study. RBM was diagnosed in twenty-five patients (11.8%), and in 18 of these patients (8.5%), the attacks had occurred subsequent to a trauma. In the CSF cultures of four patients, S. pneumoniae growth was observed. CT cisternography indicated CSF leaks in eleven patients. Moreover, bone fractures were observed in the CT images of ten patients. Ceftriaxone therapy was prescribed to 83% of the patients. Eight patients had a history of a fall in childhood, and five were involved in traffic accidents before acute bacterial meningitis. Four of the patients developed epilepsy and one developed deafness as sequelae. Since RBM attacks are frequently observed following trauma, in patients with a history of trauma who present with meningitis, the risk of recurrence should be considered.
NASA Astrophysics Data System (ADS)
Ravikumar, A. P.; Wang, J.; Brandt, A. R.
2016-12-01
Mitigating fugitive methane emissions from the oil and gas industry has become an important concern for both businesses and regulators. While recent studies have improved our understanding of emissions from all sectors of the natural gas supply chain, cost-effectively identifying leaks over expansive natural gas infrastructure remains a significant challenge. Recently, the Environmental Protection Agency (EPA) has recommended the use of optical gas imaging (OGI) technologies to be used in industry-wide leak detection and repair (LDAR) programs. However, there has been little to no systematic study of the effectiveness of infrared-camera-based OGI technology for leak detection applications. Here, we develop a physics-based model that simulates a passive infrared camera imaging a methane leak against varying background and ambient conditions. We verify the simulation tool through a series of large-volume controlled release field experiments wherein known quantities of methane were released and imaged from a range of distances. After simulator verification, we analyze the effects of environmental conditions like temperature, wind, and imaging background on the amount of methane detected from a statistically representative survey program. We also examine the effects of LDAR design parameters like imaging distance, leak size distribution, and gas composition. We show that imaging distance strongly affects leak detection - EPA's expectation of a 60% reduction in fugitive emissions based on a semi-annual LDAR survey will be realized only if leaks are imaged at a distance less than 10 m from the source under ideal environmental conditions. Local wind speed is also shown to be important. We show that minimum detection limits are 3 to 4 times higher for wet-gas compositions that contain a significant fraction of ethane and propane, resulting a significantly large leakage rate. We also explore the importance of `super-emitters' on the performance of an OGI-based leak detection program, and show that OGI technology can be used as an approximate leak-quantification method to selectively target the biggest leaks. Finally, we also provide recommendations and best-practices guidelines for achieving expected methane mitigation.
Gomes, Rachel M; Doctor, Nilesh H
2015-01-01
Reconstructive hepatico-jejunostomy is recommended for major bile duct injuries (BDIs) during cholecystectomy. Complications of biliary leak, cholangitis, bleeding, anastomotic strictures and biliary cirrhosis remain a major concern affecting a patient's outcome after surgery. The aim of this study was to analyse the results of surgical repair of major BDIs at our institution and identify predictors for the development of major complications. A retrospective study of 57 patients with major BDI after cholecystectomy referred to a tertiary hepato-biliary centre from July 1999 to July 2011 and subsequently managed with reconstructive bilio-enteric anastomosis was performed. Of 57 patents 35 (61.4%) were primary referred. 22 (38.6 %) were secondary referred, of which 17 were for correct reconstructive surgery performed elsewhere and 5 were following attempted endoscopic management. 17 (29.8%) had local and systemic perioperative complications. 13 (22.8%) had major complications (bile leak, bleed, stricture and/or biliary cirrhosis). No association was found between age, type of cholecystectomy, type of injury, vascular injury and occurrence of major complications. Secondarily referred patients after therapeutic interventions (p = 0.010) and reconstructive surgery after repair performed by non-specialists suffered an increased incidence of major complications (p = 0.032). Secondary referral was also an independent predictor of major complications (p = 0.024). Early referral of patients with no previous intervention to a tertiary hepato-biliary center and specialist surgical repair is recommended for improved outcome after reconstructive hepatico-jejunostomy for major BDIs during cholecystectomy.
Myopotential inhibition of a bipolar pacemaker caused by electrode insulation defect.
Amikam, S; Peleg, H; Lemer, J; Riss, E
1977-01-01
A patient is described in whom myopotentials orginating from the anterior abdominal wall muscle suppressed the implanted demand pacemaker despite its bipolar mode of action. This phenomenon was shown by simultaneous recording of the electrocardiogram the electromyogram. At operation, a defect in the insulation of a previously repaired epicardial electrode was found lying in close proximity to these muscles. After repair of the insulation defect, normal pacemaker function was restored. It is suggested that the myopotentials leaked into the pacing system through the insulation defect, thereby suppressing the demand unit, which maintained its bipolar mode of pacing throughout. Images PMID:145229
Steam generators regulatory practices and issues in Spain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendoza, C.; Castelao, C.; Ruiz-Colino, J.
1997-02-01
This paper presents the actual status of Spanish Steam Generator tubes, actions developed by PWR plant owners and submitted to CSN, and regulatory activities related to tube degradation mechanisms analysis; NDT tube inspection techniques; tube, tubesheet and TSPs integrity studies; tube plugging/repair criteria; preventive and corrective measures including whole SGs replacement; tube leak measurement methods and other operational aspects.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Mercury Emissions From Mercury Cell... that you cannot repair the leaking equipment without taking the cell off line, provided that you contain the dripping mercury at all times as described above, and take the cell off line as soon as...
40 CFR Table 7 to Subpart Eeee of... - Initial Compliance With Work Practice Standards
Code of Federal Regulations, 2014 CFR
2014-07-01
... equivalent control that meets the requirements in Table 4 to this subpart, item 1.a i. After emptying and... out a leak detection and repair program or equivalent control according to one of the subparts listed... (Non-Gasoline) Pt. 63, Subpt. EEEE, Table 7 Table 7 to Subpart EEEE of Part 63—Initial Compliance With...
40 CFR Table 7 to Subpart Eeee of... - Initial Compliance With Work Practice Standards
Code of Federal Regulations, 2012 CFR
2012-07-01
... equivalent control that meets the requirements in Table 4 to this subpart, item 1.a i. After emptying and... out a leak detection and repair program or equivalent control according to one of the subparts listed... (Non-Gasoline) Pt. 63, Subpt. EEEE, Table 7 Table 7 to Subpart EEEE of Part 63—Initial Compliance With...
40 CFR Table 7 to Subpart Eeee of... - Initial Compliance With Work Practice Standards
Code of Federal Regulations, 2013 CFR
2013-07-01
... equivalent control that meets the requirements in Table 4 to this subpart, item 1.a i. After emptying and... out a leak detection and repair program or equivalent control according to one of the subparts listed... (Non-Gasoline) Pt. 63, Subpt. EEEE, Table 7 Table 7 to Subpart EEEE of Part 63—Initial Compliance With...
Ready for Work. Advocates Series. Action Brief No.2
ERIC Educational Resources Information Center
Forum for Youth Investment, 2006
2006-01-01
In the past, much attention has been paid to the leaks in the "education pipeline", but now employers, youth and communities are focusing on repairing the "work pipeline" to ensure that young people are ready for work by age 21. This issue brief is the second in a series developed by the Forum for Youth Investment, Connect for Kids, Voices for…
2010-11-10
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers will focus their attention on the ground umbilical carrier plate (GUCP), which is on space shuttle Discovery's orange external fuel tank at the end of the access arm. A hydrogen gas leak at that location during tanking for Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Jack Pfaller
2010-11-10
CAPE CANAVERAL, Fla. -- On Launch Pad 39A at NASA's Kennedy Space Center in Florida, workers are focusing their attention on the ground umbilical carrier plate (GUCP), which is on space shuttle Discovery's orange external fuel tank at the end of the access arm. A hydrogen gas leak at that location during tanking for Discovery's STS-133 mission to the International Space Station caused the launch attempt to be scrubbed Nov. 5. The GUCP will be examined to determine the cause of the hydrogen leak and then repaired. The GUCP is the overboard vent to the pad and the flame stack where the excess hydrogen is burned off. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Jack Pfaller