Sample records for ct diagnostic values

  1. 18F-FDG PET/CT in Detecting Metastatic Infection in Children.

    PubMed

    Kouijzer, Ilse J E; Blokhuis, Gijsbert J; Draaisma, Jos M T; Oyen, Wim J G; de Geus-Oei, Lioe-Fee; Bleeker-Rovers, Chantal P

    2016-04-01

    Metastatic infection is a severe complication of bacteremia with high morbidity and mortality. The aim of this study was to investigate the diagnostic value of 18F-FDG PET combined with CT (FDG PET/CT) in children suspected of having metastatic infection. The results of FDG PET/CT scans performed in children because of suspected metastatic infection from September 2003 to June 2013 were analyzed retrospectively. The results were compared with the final clinical diagnosis. FDG PET/CT was performed in 13 children with suspected metastatic infection. Of the total number of FDG PET/CT scans, 38% were clinically helpful. Positive predictive value of FDG PET/CT was 71%, and negative predictive value was 100%. FDG PET/CT appears to be a valuable diagnostic technique in children with suspected metastatic infection. Prospective studies of FDG PET/CT as part of a structured diagnostic protocol are needed to assess the exact additional diagnostic value.

  2. The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis

    PubMed Central

    Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M

    2017-01-01

    The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a “routine” PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures. PMID:29348980

  3. The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis.

    PubMed

    Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M

    2017-01-01

    The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a "routine" PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures.

  4. PET-PANC: multicentre prospective diagnostic accuracy and health economic analysis study of the impact of combined modality 18fluorine-2-fluoro-2-deoxy-d-glucose positron emission tomography with computed tomography scanning in the diagnosis and management of pancreatic cancer.

    PubMed

    Ghaneh, Paula; Hanson, Robert; Titman, Andrew; Lancaster, Gill; Plumpton, Catrin; Lloyd-Williams, Huw; Yeo, Seow Tien; Edwards, Rhiannon Tudor; Johnson, Colin; Abu Hilal, Mohammed; Higginson, Antony P; Armstrong, Tom; Smith, Andrew; Scarsbrook, Andrew; McKay, Colin; Carter, Ross; Sutcliffe, Robert P; Bramhall, Simon; Kocher, Hemant M; Cunningham, David; Pereira, Stephen P; Davidson, Brian; Chang, David; Khan, Saboor; Zealley, Ian; Sarker, Debashis; Al Sarireh, Bilal; Charnley, Richard; Lobo, Dileep; Nicolson, Marianne; Halloran, Christopher; Raraty, Michael; Sutton, Robert; Vinjamuri, Sobhan; Evans, Jonathan; Campbell, Fiona; Deeks, Jon; Sanghera, Bal; Wong, Wai-Lup; Neoptolemos, John P

    2018-02-01

    Pancreatic cancer diagnosis and staging can be difficult in 10-20% of patients. Positron emission tomography (PET)/computed tomography (CT) adds precise anatomical localisation to functional data. The use of PET/CT may add further value to the diagnosis and staging of pancreatic cancer. To determine the incremental diagnostic accuracy and impact of PET/CT in addition to standard diagnostic work-up in patients with suspected pancreatic cancer. A multicentre prospective diagnostic accuracy and clinical value study of PET/CT in suspected pancreatic malignancy. Patients with suspected pancreatic malignancy. All patients to undergo PET/CT following standard diagnostic work-up. The primary outcome was the incremental diagnostic value of PET/CT in addition to standard diagnostic work-up with multidetector computed tomography (MDCT). Secondary outcomes were (1) changes in patients' diagnosis, staging and management as a result of PET/CT; (2) changes in the costs and effectiveness of patient management as a result of PET/CT; (3) the incremental diagnostic value of PET/CT in chronic pancreatitis; (4) the identification of groups of patients who would benefit most from PET/CT; and (5) the incremental diagnostic value of PET/CT in other pancreatic tumours. Between 2011 and 2013, 589 patients with suspected pancreatic cancer underwent MDCT and PET/CT, with 550 patients having complete data and in-range PET/CT. Sensitivity and specificity for the diagnosis of pancreatic cancer were 88.5% and 70.6%, respectively, for MDCT and 92.7% and 75.8%, respectively, for PET/CT. The maximum standardised uptake value (SUV max. ) for a pancreatic cancer diagnosis was 7.5. PET/CT demonstrated a significant improvement in relative sensitivity ( p  = 0.01) and specificity ( p  = 0.023) compared with MDCT. Incremental likelihood ratios demonstrated that PET/CT significantly improved diagnostic accuracy in all scenarios ( p  < 0.0002). PET/CT correctly changed the staging of pancreatic cancer in 56 patients ( p  = 0.001). PET/CT influenced management in 250 (45%) patients. PET/CT stopped resection in 58 (20%) patients who were due to have surgery. The benefit of PET/CT was limited in patients with chronic pancreatitis or other pancreatic tumours. PET/CT was associated with a gain in quality-adjusted life-years of 0.0157 (95% confidence interval -0.0101 to 0.0430). In the base-case model PET/CT was seen to dominate MDCT alone and is thus highly likely to be cost-effective for the UK NHS. PET/CT was seen to be most cost-effective for the subgroup of patients with suspected pancreatic cancer who were thought to be resectable. PET/CT provided a significant incremental diagnostic benefit in the diagnosis of pancreatic cancer and significantly influenced the staging and management of patients. PET/CT had limited utility in chronic pancreatitis and other pancreatic tumours. PET/CT is likely to be cost-effective at current reimbursement rates for PET/CT to the UK NHS. This was not a randomised controlled trial and therefore we do not have any information from patients who would have undergone MDCT only for comparison. In addition, there were issues in estimating costs for PET/CT. Future work should evaluate the role of PET/CT in intraductal papillary mucinous neoplasm and prognosis and response to therapy in patients with pancreatic cancer. Current Controlled Trials ISRCTN73852054 and UKCRN 8166. The National Institute for Health Research Health Technology Assessment programme.

  5. Diagnostic performance of multi-slice CT angiography combined with enterography for small bowel obstruction and intestinal ischaemia.

    PubMed

    He, Bosheng; Gu, Jinhua; Huang, Sheng; Gao, Xuesong; Fan, Jinhe; Sheng, Meihong; Wang, Lin; Gong, Shenchu

    2017-02-01

    This study was performed to evaluate the diagnostic performance of multi-slice CT angiography combined with enterography in determining the cause and location of obstruction as well as intestinal ischaemia in patients with small bowel obstruction (SBO). This study retrospectively summarized the image data of 57 SBO patients who received both multi-slice CT angiography and enterography examination between December 2012 and May 2013. The CT diagnoses of SBO and intestinal ischaemia were correlated with the findings at surgery or digital subtraction angiography, which were set as standard references. Multi-slice CT angiography and enterography indicated that the cause of SBO in three patients was misjudged, suggesting a diagnostic accuracy of 94.7%. In one patient the level of obstruction was incorrect, demonstrating a diagnostic accuracy of 98.2%. Based on the results of the receiver operating characteristic (ROC) curve analysis, the diagnostic criterion for ischaemic SBO was at least two of the four CT signs (circumferential bowel wall thickening, reduced enhancement of the intestinal wall, mesenteric oedema and mesenteric vascular engorgement). The criterion yielded a sensitivity of 94.4%, a specificity of 92.3%, a positive predicted value of 85.0% and a negative predicted value of 97.3%, and the area under curve (AUC) was 0.92 (95% CI, 0.85-0.99). Multi-slice CT angiography and enterography have high diagnostic value in identifying the cause and site of SBO. In addition, the suggested diagnostic criterion using CT signs is helpful for diagnosing intestinal ischaemia in SBO patients. © 2016 The Royal Australian and New Zealand College of Radiologists.

  6. Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.

    PubMed

    Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T

    2017-12-01

    The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.

  7. The role of routine preoperative EUS when performed after contrast enhanced CT in the diagnostic work-up in patients suspected of pancreatic or periampullary cancer.

    PubMed

    Cieslak, Kasia P; van Santvoort, Hjalmar C; Vleggaar, Frank P; van Leeuwen, Maarten S; ten Kate, Fibo J; Besselink, Marc G; Molenaar, I Quintus

    2014-01-01

    In patients suspected of pancreatic or periampullary cancer, abdominal contrast-enhanced computed tomography (CT) is the standard diagnostic modality. A supplementary endoscopic ultrasonography (EUS) is often performed, although there is only limited evidence of its additional diagnostic value. The aim of the study is to evaluate the additional diagnostic value of EUS over CT in deciding on exploratory laparotomy in patients suspected of pancreatic or periampullary cancer. We retrospectively analyzed 86 consecutive patients who routinely underwent CT and EUS before exploratory laparotomy with or without pancreatoduodenectomy for suspected pancreatic or periampullary carcinoma between 2007 and 2010. Primary outcomes were visibility of a mass, resectability on CT/EUS and resection with curative intent. A mass was visible on CT in 72/86 (84%) patients. In these 72 patients, EUS demonstrated a mass in 64/72 (89%) patients. Resectability was accurately predicted by CT in 65/72 (90%) and by EUS in 58/72 (81%) patients. In 14/86 (16%) patients no mass was seen on CT. EUS showed a mass in 12/14 (86%) of these patients. A malignant lesion was histological proven in 11/12 (92%) of these patients. Overall, resectability was accurately predicted by CT and EUS in 90% (77/86) and 84% (72/86), respectively. In patients with a visible mass on CT, suspected for pancreatic or periampullary cancer, EUS has no additional diagnostic value, does not influence the decision to perform laparotomy and should therefore not be performed routinely. In patients without a visible mass on CT, EUS is useful to confirm the presence of a tumor. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  8. The possibility of application of spiral brain computed tomography to traumatic brain injury.

    PubMed

    Lim, Daesung; Lee, Soo Hoon; Kim, Dong Hoon; Choi, Dae Seub; Hong, Hoon Pyo; Kang, Changwoo; Jeong, Jin Hee; Kim, Seong Chun; Kang, Tae-Sin

    2014-09-01

    The spiral computed tomography (CT) with the advantage of low radiation dose, shorter test time required, and its multidimensional reconstruction is accepted as an essential diagnostic method for evaluating the degree of injury in severe trauma patients and establishment of therapeutic plans. However, conventional sequential CT is preferred for the evaluation of traumatic brain injury (TBI) over spiral CT due to image noise and artifact. We aimed to compare the diagnostic power of spiral facial CT for TBI to that of conventional sequential brain CT. We evaluated retrospectively the images of 315 traumatized patients who underwent both brain CT and facial CT simultaneously. The hemorrhagic traumatic brain injuries such as epidural hemorrhage, subdural hemorrhage, subarachnoid hemorrhage, and contusional hemorrhage were evaluated in both images. Statistics were performed using Cohen's κ to compare the agreement between 2 imaging modalities and sensitivity, specificity, positive predictive value, and negative predictive value of spiral facial CT to conventional sequential brain CT. Almost perfect agreement was noted regarding hemorrhagic traumatic brain injuries between spiral facial CT and conventional sequential brain CT (Cohen's κ coefficient, 0.912). To conventional sequential brain CT, sensitivity, specificity, positive predictive value, and negative predictive value of spiral facial CT were 92.2%, 98.1%, 95.9%, and 96.3%, respectively. In TBI, the diagnostic power of spiral facial CT was equal to that of conventional sequential brain CT. Therefore, expanded spiral facial CT covering whole frontal lobe can be applied to evaluate TBI in the future. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Diagnostic value of FDG-PET/(CT) in children with fever of unknown origin and unexplained fever during immune suppression.

    PubMed

    Blokhuis, Gijsbert J; Bleeker-Rovers, Chantal P; Diender, Marije G; Oyen, Wim J G; Draaisma, Jos M Th; de Geus-Oei, Lioe-Fee

    2014-10-01

    Fever of unknown origin (FUO) and unexplained fever during immune suppression in children are challenging medical problems. The aim of this study is to investigate the diagnostic value of fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and FDG-PET combined with computed tomography (FDG-PET/CT) in children with FUO and in children with unexplained fever during immune suppression. All FDG-PET/(CT) scans performed in the Radboud university medical center for the evaluation of FUO or unexplained fever during immune suppression in the last 10 years were reviewed. Results were compared with the final clinical diagnosis. FDG-PET/(CT) scans were performed in 31 children with FUO. A final diagnosis was established in 16 cases (52 %). Of the total number of scans, 32 % were clinically helpful. The sensitivity and specificity of FDG-PET/CT in these patients was 80 % and 78 %, respectively. FDG-PET/(CT) scans were performed in 12 children with unexplained fever during immune suppression. A final diagnosis was established in nine patients (75 %). Of the total number of these scans, 58 % were clinically helpful. The sensitivity and specificity of FDG-PET/CT in children with unexplained fever during immune suppression was 78 % and 67 %, respectively. FDG-PET/CT appears a valuable imaging technique in the evaluation of children with FUO and in the diagnostic process of children with unexplained fever during immune suppression. Prospective studies of FDG-PET/CT as part of a structured diagnostic protocol are warranted to assess the additional diagnostic value.

  10. Diagnostic value of 18F-FDG-PET/CT for the follow-up and restaging of soft tissue sarcomas in adults.

    PubMed

    Kassem, T W; Abdelaziz, O; Emad-Eldin, S

    2017-10-01

    The purpose of this study was to evaluate the clinical utility of 2-[ 18 F] fluoro-2-deoxy-D-glucose ( 18 FDG) positron emission tomography (PET)/computed tomography (CT) ( 18 F-FDG-PET/CT) in the follow-up of adult patients with soft tissue sarcomas. We prospectively evaluated 37 consecutive patients with known soft tissue sarcoma with 18 F-FDG-PET/CT examination for suspected recurrence of disease. They were 21 men and 16 women with a mean age of 49.6±10.6 (SD) years (range, 34-75years). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 18 F-FDG-PET/CT examination were calculated on a per patient basis. 18 F-FDG-PET/CT showed an overall diagnostic accuracy of 91.8%, sensitivity of 90% and a specificity of 100%. The positive predictive value and negative predictive value were 100 and 70%, respectively. The 18 F-FDG-PET/CT interpretations were correct in 34/37 patients (91.8%). Incorrect interpretations occurred in three patients (8.1%). Reasons for false negative findings were low 18 F-FDG uptake of local recurrence in one patient and low 18 F-FDG uptake of subcentimetric inguinal lymph node metastases. 18 F-FDG-PET/CT has a high diagnostic value in the follow-up of patients with soft tissue sarcoma. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  11. [Changing the internal cost allocation (ICA) on DRG shares : Example of computed tomography in a university radiology setting].

    PubMed

    Wirth, K; Zielinski, P; Trinter, T; Stahl, R; Mück, F; Reiser, M; Wirth, S

    2016-08-01

    In hospitals, the radiological services provided to non-privately insured in-house patients are mostly distributed to requesting disciplines through internal cost allocation (ICA). In many institutions, computed tomography (CT) is the modality with the largest amount of allocation credits. The aim of this work is to compare the ICA to respective DRG (Diagnosis Related Groups) shares for diagnostic CT services in a university hospital setting. The data from four CT scanners in a large university hospital were processed for the 2012 fiscal year. For each of the 50 DRG groups with the most case-mix points, all diagnostic CT services were documented including their respective amount of GOÄ allocation credits and invoiced ICA value. As the German Institute for Reimbursement of Hospitals (InEK) database groups the radiation disciplines (radiology, nuclear medicine and radiation therapy) together and also lacks any modality differentiation, the determination of the diagnostic CT component was based on the existing institutional distribution of ICA allocations. Within the included 24,854 cases, 63,062,060 GOÄ-based performance credits were counted. The ICA relieved these diagnostic CT services by € 819,029 (single credit value of 1.30 Eurocent), whereas accounting by using DRG shares would have resulted in € 1,127,591 (single credit value of 1.79 Eurocent). The GOÄ single credit value is 5.62 Eurocent. The diagnostic CT service was basically rendered as relatively inexpensive. In addition to a better financial result, changing the current ICA to DRG shares might also mean a chance for real revenues. However, the attractiveness considerably depends on how the DRG shares are distributed to the different radiation disciplines of one institution.

  12. Added Value of SPECT/CT in the Evaluation of Benign Bone Diseases of the Appendicular Skeleton.

    PubMed

    Abikhzer, Gad; Srour, Saher; Keidar, Zohar; Bar-Shalom, Rachel; Kagna, Olga; Israel, Ora; Militianu, Daniela

    2016-04-01

    Bone scintigraphy is a sensitive technique to detect altered bone mineralization but has limited specificity. The use of SPECT/CT has improved significantly the diagnostic accuracy of bone scintigraphy, in patients with cancer as well as in evaluation of benign bone disease. It provides precise localization and characterization of tracer-avid foci, shortens the diagnostic workup, and decreases patient anxiety. Through both the SPECT and the CT components, SPECT/CT has an incremental value in characterizing benign bone lesions, specifically in the appendicular skeleton, as illustrated by present case series.

  13. [Diagnostic value of ¹⁸F-fluorodexyglucose positron emission tomography combined with contrast enhanced computed tomography in colorectal cancer liver metastasis].

    PubMed

    Zhang, Zhanwen; Lyu, Qinghu; Chen, Feini; Liao, Siqin; Zhang, Jie; Hu, Rui; Hu, Ping

    2015-03-01

    To explore the preoperative diagnostic value of ¹⁸F-fluorodexyglucose positron emission tomography combined with contrast enhanced computed tomography (¹⁸F-FDG PET-ceCT) in patients with colorectal cancer liver metastasis. Clinical and imaging data of 58 patients with suspicious colorectal cancer liver metastasis between April 2010 and March 2013 were retrospectively evaluated. All the patients underwent ¹⁸F-FDG PET-ceCT. On the basis of definitive diagnosis, the sensitivity, specificity, accuracy and consistency of routine PET-CT, ceCT and ¹⁸F-FDG PET-ceCT were calculated. A total of 147 suspicious lesions of colorectal cancer liver metastasis were found in 58 patients. Finally, 125 lesions were confinmed as malignant, of which 58 (46.4%) lesions were less than 1.0 cm. The other 22 lesions were confinmed as benign, of which 17 (77.3%) lesions were less than 1.0 cm. The diagnostic accuracy of routine PET-CT, ceCT and ¹⁸F-FDG PET-ceCT in colorectal cancer liver metastasis for the lesions more than 1.0 cm was 100%, 93.1%, 100% respectively, and the consistency with final diagnosis was perfect, moderate, and perfect respectively (Kappa value 01.00, 0.408, 1.00). For the lesions less than 1.0 cm, the accuracy was 42.7%, 78.7%, 94.7% respectively, and the consistency with definitive diagnosis was insignificance, fair, and almost perfect respectively (Kappa value -0.005, 0.305, 0.848). The area under curve(AUC) was 0.525 (95% CI: 0.407-0.462) for routine PET-CT, 0.651(95% CI:0.532-0.757) for ceCT, and 0.924 (95% CI:0.839-0.972) for ¹⁸F-FDG PET-ceCT respectively. The AUC of ¹⁸F-FDG PET-ceCT was significantly larger than that of routine PET-CT (Z=5.559, P<0.05) or ceCT (Z=4.183, P<0.05). (18)F-FDG PET-ceCT can improve the diagnostic accuracy for smaller lesions of colorectal cancer liver metastasis.

  14. Differentiation and diagnosis of benign and malignant testicular lesions using 18F-FDG PET/CT.

    PubMed

    Shao, Dan; Gao, Qiang; Tian, Xu-Wei; Wang, Si-Yun; Liang, Chang-Hong; Wang, Shu-Xia

    2017-08-01

    The purpose of this study was to evaluate the differential diagnostic value of 18 F-fluorodeoxy glucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) for benign and malignant testicular lesions. The PET/CT scans of 53 patients with testicular lesions confirmed by biopsy or surgical pathology were retrospectively analyzed. There were 32 cases of malignant tumors and 21 cases of benign lesions. Differences in the maximum standardized uptake value (SUVmax) measurements and the SUVmax lesion/background ratios between benign and malignant lesions were analyzed. The diagnostic value of this PET/CT modality for the differential diagnosis of benign versus malignant testicular lesions was calculated. The differences in the SUVmax measurements and the SUVmax lesion/background ratios between benign and malignant lesions were statistically significant (SUVmax: Z=-4.295, p=0.000; SUVmax lesion/background ratio: Z=-5.219, p=0.000); specifically, both of these indicators were higher in malignant lesions compared to benign lesions. An SUVmax of 3.75 was the optimal cutoff value to differentiate between benign and malignant testicular lesions. The diagnostic sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of this PET/CT modality in the differential diagnosis of benign versus malignant testicular lesions were 90.6%, 80.9%, 86.8%, 87.9%, and 85.0%, respectively. 18 F-FDG PET/CT can accurately identify benign and malignant testicular lesions. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Contrast-enhanced small-animal PET/CT in cancer research: strong improvement of diagnostic accuracy without significant alteration of quantitative accuracy and NEMA NU 4-2008 image quality parameters.

    PubMed

    Lasnon, Charline; Quak, Elske; Briand, Mélanie; Gu, Zheng; Louis, Marie-Hélène; Aide, Nicolas

    2013-01-17

    The use of iodinated contrast media in small-animal positron emission tomography (PET)/computed tomography (CT) could improve anatomic referencing and tumor delineation but may introduce inaccuracies in the attenuation correction of the PET images. This study evaluated the diagnostic performance and accuracy of quantitative values in contrast-enhanced small-animal PET/CT (CEPET/CT) as compared to unenhanced small animal PET/CT (UEPET/CT). Firstly, a NEMA NU 4-2008 phantom (filled with 18F-FDG or 18F-FDG plus contrast media) and a homemade phantom, mimicking an abdominal tumor surrounded by water or contrast media, were used to evaluate the impact of iodinated contrast media on the image quality parameters and accuracy of quantitative values for a pertinent-sized target. Secondly, two studies in 22 abdominal tumor-bearing mice and rats were performed. The first animal experiment studied the impact of a dual-contrast media protocol, comprising the intravenous injection of a long-lasting contrast agent mixed with 18F-FDG and the intraperitoneal injection of contrast media, on tumor delineation and the accuracy of quantitative values. The second animal experiment compared the diagnostic performance and quantitative values of CEPET/CT versus UEPET/CT by sacrificing the animals after the tracer uptake period and imaging them before and after intraperitoneal injection of contrast media. There was minimal impact on IQ parameters (%SDunif and spillover ratios in air and water) when the NEMA NU 4-2008 phantom was filled with 18F-FDG plus contrast media. In the homemade phantom, measured activity was similar to true activity (-0.02%) and overestimated by 10.30% when vials were surrounded by water or by an iodine solution, respectively. The first animal experiment showed excellent tumor delineation and a good correlation between small-animal (SA)-PET and ex vivo quantification (r2 = 0.87, P < 0.0001). The second animal experiment showed a good correlation between CEPET/CT and UEPET/CT quantitative values (r2 = 0.99, P < 0.0001). Receiver operating characteristic analysis demonstrated better diagnostic accuracy of CEPET/CT versus UEPET/CT (senior researcher, area under the curve (AUC) 0.96 versus 0.77, P = 0.004; junior researcher, AUC 0.78 versus 0.58, P = 0.004). The use of iodinated contrast media for small-animal PET imaging significantly improves tumor delineation and diagnostic performance, without significant alteration of SA-PET quantitative accuracy and NEMA NU 4-2008 IQ parameters.

  16. Diagnostic value of [(18)F]-FDG PET/CT in children with fever of unknown origin or unexplained signs of inflammation.

    PubMed

    Jasper, Niklas; Däbritz, Jan; Frosch, Michael; Loeffler, Markus; Weckesser, Matthias; Foell, Dirk

    2010-01-01

    Fever of unknown origin (FUO) and unexplained signs of inflammation are challenging medical problems especially in children and predominantly caused by infections, malignancies or noninfectious inflammatory diseases. The aim of this study was to assess the diagnostic value of (18)F-FDG PET and PET/CT in the diagnostic work-up in paediatric patients. In this retrospective study, 47 FDG PET and 30 PET/CT scans from 69 children (median age 8.1 years, range 0.2-18.1 years, 36 male, 33 female) were analysed. The diagnostic value of PET investigations in paediatric patients presenting with FUO (44 scans) or unexplained signs of inflammation without fever (33 scans) was analysed. A diagnosis in paediatric patients with FUO or unexplained signs of inflammation could be established in 32 patients (54%). Of all scans, 63 (82%) were abnormal, and of the total number of 77 PET and PET/CT scans 35 (45%) were clinically helpful. In patients with a final diagnosis, scans were found to have contributed to the diagnosis in 73%. Laboratory, demographic or clinical parameters of the children did not predict the usefulness of FDG PET scans. This is the first larger study demonstrating that FDG PET and PET/CT may be valuable diagnostic tools for the evaluation of children with FUO and unexplained signs of inflammation. Depicting inflammation in the whole body, while not being traumatic, it is attractive for use especially in children. The combination of PET with CT seems to be superior, since the site of inflammation can be localized more accurately.

  17. Diagnostic accuracy of CT in assessing extra-regional lymphadenopathy in pancreatic and peri-ampullary cancer: a systematic review and meta-analysis.

    PubMed

    Tseng, Dorine S J; van Santvoort, Hjalmar C; Fegrachi, Samira; Besselink, Marc G; Zuithoff, Nicolaas P A; Borel Rinkes, Inne H; van Leeuwen, Maarten S; Molenaar, I Quintus

    2014-12-01

    Computed tomography (CT) is the most widely used method to assess resectability of pancreatic and peri-ampullary cancer. One of the contra-indications for curative resection is the presence of extra-regional lymph node metastases. This meta-analysis investigates the accuracy of CT in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. We systematically reviewed the literature according to the PRISMA guidelines. Studies reporting on CT assessment of extra-regional lymph nodes in patients undergoing pancreatoduodenectomy were included. Data on baseline characteristics, CT-investigations and histopathological outcomes were extracted. Diagnostic accuracy, positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity were calculated for individual studies and pooled data. After screening, 4 cohort studies reporting on CT-findings and histopathological outcome in 157 patients with pancreatic or peri-ampullary cancer were included. Overall, diagnostic accuracy, specificity and NPV varied from 63 to 81, 80-100% and 67-90% respectively. However, PPV and sensitivity ranged from 0 to 100% and 0-38%. Pooled sensitivity, specificity, PPV and NPV were 25%, 86%, 28% and 84% respectively. CT has a low diagnostic accuracy in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. Therefore, suspicion of extra-regional lymph node metastases on CT alone should not be considered a contra-indication for exploration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. CT coronary angiography and exercise ECG in a population with chest pain and low-to-intermediate pre-test likelihood of coronary artery disease.

    PubMed

    Maffei, Erica; Seitun, Sara; Martini, Chiara; Palumbo, Alessandro; Tarantini, Giuseppe; Berti, Elena; Grilli, Roberto; Tedeschi, Carlo; Messalli, Giancarlo; Guaricci, Andrea; Weustink, Annick C; Mollet, Nico Ra; Cademartiri, Filippo

    2010-12-01

    To evaluate diagnostic accuracy of exercise ECG (ex-ECG) versus 64-slice CT coronary angiography (CT-CA) for the detection of significant coronary artery stenosis in a population with low-to-intermediate pre-test likelihood of coronary artery disease (CAD). Retrospective single centre. Tertiary academic hospital. 177 consecutive patients (88 men, 89 women, mean age 53.5±7.6 years) with chest pain and low-to-intermediate pre-test likelihood of CAD were retrospectively enrolled. All patients underwent ex-ECG, CT-CA and invasive coronary angiography (ICA). A lumen diameter reduction of ≥50% was considered as significant stenosis for CT-CA. Ex-ECG was classified as positive, negative or non-diagnostic. were compared with ICA. Diagnostic accuracy of CT-CA and ex-ECG was calculated using ICA as the reference standard. A parallel comparative analysis using a cut-off value of 70% for significant lumen reduction was also performed too. Results ICA disclosed an absence of significant stenosis (≥50% luminal narrowing) in 85.3% (151/177) patients, single-vessel disease in 9.0% (16/177) patients and multivessel disease in 5.6% (10/177) patients. Prevalence of obstructive disease at ICA was 14.7% (26/177). Sensitivity, specificity, positive and negative predictive values at the patient level were 100.0%, 98.7%, 92.9%, 100%, respectively, for CT-CA and 46.2%, 16.6%, 8.7%, 64.1%, respectively, for ex-ECG. Agreement between CT-CA and ex-ECG was 20.9%. CT-CA performed equally well in men and women, while ex-ECG had a better performance in men. After considering the cut-off value of 70% for significant stenosis, the difference between CT-CA and ex-ECG remained significant (p<0.01), with a low agreement (21.5%). CT-CA provides optimal diagnostic performance in patients with atypical chest pain and low-to-intermediate risk of CAD. Ex-ECG has poor diagnostic accuracy in this population. Concerns are related to risk of radiation dose versus the benefits of correct disease stratification.

  19. Diagnostic and prognostic value of 18F-FDG PET/CT in recurrent germinal tumor carcinoma.

    PubMed

    Alongi, Pierpaolo; Evangelista, Laura; Caobelli, Federico; Spallino, Marianna; Gianolli, Luigi; Midiri, Massimo; Picchio, Maria

    2018-01-01

    The aim of this bicentric retrospective study was to assess the diagnostic performance, the prognostic value, the incremental prognostic value and the impact on therapeutic management of 18 F-FDG PET/CT in patients with suspected recurrent germinal cell testicular carcinoma (GCT). From the databases of two centers including 31,500 18 F-FDG PET/CT oncological studies, 114 patients affected by GCT were evaluated in a retrospective study. All 114 patients underwent 18 F-FDG PET/CT for suspected recurrent disease. Diagnostic performance of visually interpreted 18 F-FDG PET/CT and potential impact on the treatment decision were assessed using histology (17 patients), other diagnostic imaging modalities (i.e., contrast enhanced CT in 89 patients and MRI in 15) and clinical follow-up (114 patients) as reference. Progression-free survival (PFS) and overall survival (OS) rates were computed by means of Kaplan-Meier survival analysis. The progression rate (Hazard Ratio-HR) was determined using univariate Cox regression analysis by considering various clinical variables. Recurrent GCT was confirmed in 47 of 52 patients with pathological 18 F-FDG PET/CT findings, by means of histology in 18 patients and by other diagnostic imaging modalities/follow-up in 29. Sensitivity, specificity, accuracy, positive and negative likelihood ratio (LR+ and LR-, respectively), pre-test Odds-ratio and post-test Odds-ratio of 18 FDG PET/CT were 86.8%, 90.2%, 88.4%, 8.85, 0.14, 0.85, 8.85, respectively. 18 F-FDG PET/CT impacted significantly on therapeutic management in 26/114 (23%) cases (from palliative to curative in 12 patients, from "wait and watch" to new chemotherapy in six patients and the "wait-and-watch" approach in eight patients with unremarkable findings). At 2 and 5-year follow-up, PFS was significantly longer in patients with a negative than a pathological 18 F-FDG PET/CT scan (98% and 95% vs 48% and 38%, respectively; p = 0.02). An unremarkable scan was associated also with a longer OS (98% after 2 years and 95% after 5 years, p = 0.02). At univariate Cox regression analysis, a pathological 18 F-FDG PET/CT scan was associated with an increased risk of disease progression (HR = 24.3, CI 95% 14.1-40.6; p = 0.03) and lower OS (HR = 17.3 CI 95% 4,9-77; p < 0.001). Its prognostic value was confirmed also if tested against advanced disease at diagnosis and rising Human Chorionic Gonadotropin Beta (HCGB) or Alpha-Fetoprotein (AFP) (HR = 7.3 for STAGE III-PET+, p = 0.03; HR = 14.3 elevated HCGB-PET+, p = 0.02; HR 10.7 elevated AFP-PET+, p = 0.01) At multivariate analysis, only a pathological 18 F-FDG PET/CT scan and advanced disease in terms of TNM staging were predictors of disease progression and OS. 18 F-FDG PET/CT showed incremental value over other variables both in predicting PFS (chi-square from 24 to 40, p < 0.001) and OS (chi-square from 32 to 38, p = 0.003). 18 F-FDG PET/CT has a very good diagnostic performance in patients with suspected recurrent GCT and has an important prognostic value in assessing the rate of PFS and OS. Furthermore, 18 F-FDG PET/CT impacted the therapeutic regimen in 23% of patients, thus providing a significant impact in the restaging process.

  20. Clinical impact of 18 F-FDG positron emission tomography/CT on adenoid cystic carcinoma of the head and neck.

    PubMed

    Jung, Ji-Hoon; Lee, Sang-Woo; Son, Seung Hyun; Kim, Choon-Young; Lee, Chang-Hee; Jeong, Ju Hye; Jeong, Shin Young; Ahn, Byeong-Cheol; Lee, Jaetae

    2017-03-01

    The purpose of this retrospective study was to assess the diagnostic value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT and the prognostic value of metabolic PET parameters in patients with adenoid cystic carcinoma of the head and neck (ACCHN). Forty patients with newly diagnosed ACCHN were enrolled in this study. We investigated the diagnostic value of 18 F-FDG PET/CT for detecting and staging compared to conventional CT. Kaplan-Meier survival analysis for progression-free survival (PFS) was performed with clinicopathological factors and metabolic PET parameters. The 18 F-FDG PET/CT showed comparable sensitivity (92.3%) to conventional CT for lesion detection, and changed staging and management plan in 6 patients (15.0%). Lower PFS rates were associated with advanced T classification, advanced TNM classification, high maximum standardized uptake value (SUVmax; >5.1), and high total lesion glycolysis (>40.1) of the primary tumor. The 18 F-FDG PET/CT can provide additional information for initial staging, and metabolic PET parameters may serve as prognostic factors of ACCHN. © 2016 Wiley Periodicals, Inc. Head Neck 39: 447-455, 2017. © 2016 Wiley Periodicals, Inc.

  1. Diagnostic role of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for early and atypical bone metastases.

    PubMed

    Chen, Xiao-Liang; Li, Qian; Cao, Lin; Jiang, Shi-Xi

    2014-01-01

    The bone metastasis appeared early before the bone imaging for most of the above patients. (99)Tc(m)-MDP ((99)Tc(m) marked methylene diphosphonate) bone imaging could diagnosis the bone metastasis with highly sensitivity, but with lower specificity. The aim of this study is to explore the diagnostic value of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for the early period atypical bone metastases. 15 to 30 mCi (99)Tc(m)-MDP was intravenously injected to the 34 malignant patients diagnosed as doubtful early bone metastases. SPECT, CT and SPECT/CT images were captured and analyzed consequently. For the patients diagnosed as early period atypical bone metastases by SPECT/CT, combining the SPECT/CT and MRI together as the SPECT/MRI integrated image. The obtained SPECT/MRI image was analyzed and compared with the pathogenic results of patients. The results indicated that 34 early period doubtful metastatic focus, including 34 SPECT positive focus, 17 focus without special changes by using CT method, 11 bone metastases focus by using SPECT/CT method, 23 doubtful bone metastases focus, 8 doubtful bone metastases focus, 14 doubtful bone metastases focus and 2 focus without clear image. Totally, SPECT/CT combined with SPECT/MRI method diagnosed 30 bone metastatic focus and 4 doubtfully metastatic focus. In conclusion, (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging shows a higher diagnostic value for the early period bone metastases, which also enhances the diagnostic accuracy rate.

  2. Diagnostic value of 64-slice spiral computed tomography imaging of the urinary tract during the excretory phase for urinary tract obstruction.

    PubMed

    Zhao, De-Li; Jia, Guang-Sheng; Chen, Peng; Liu, Xin-Ding; Shu, Sheng-Jie; Ling, Zai-Sheng; Fan, Ting-Ting; Shen, Xiu-Fen; Zhang, Jin-Ling

    2017-11-01

    The present study aimed to assess the diagnostic value of 64-slice spiral computed tomography (CT) imaging of the urinary tract during the excretory phase for urinary tract obstruction. CT imaging of the urinary tract during the excretory phase was performed in 46 patients that had been diagnosed with urinary tract obstruction by B-mode ultrasound imaging or clinical manifestations. It was demonstrated that out of the 46 patients, 18 had pelvic and ureteral calculi, 12 cases had congenital malformations, 3 had ureteral stricture caused by urinary tract infection and 13 cases had malignant tumors of the urinary tract. The average X-ray dose planned for the standard CT scan of the urinary tract group 1 was 14.11±5.45 mSv, while the actual X-ray dose administered for the CT scan during the excretory phase group 2 was 9.01±4.56 mSv. The difference between the two groups was statistically significant (t=15.36; P<0.01). The results of the present study indicate that CT scanning of the urinary tract during the excretory phase has a high diagnostic value for urinary tract obstruction.

  3. New diagnostic pathways urgently needed. Protocol of PET Guidance I pilot study: positron emission tomography in suspected cardiac implantable electronic device-related infection.

    PubMed

    Marciniak-Emmons, Marta Barbara; Sterliński, Maciej; Syska, Paweł; Maciąg, Aleksander; Farkowski, Michał Mirosław; Firek, Bohdan; Dziuk, Mirosław; Zając, Dariusz; Pytkowski, Mariusz; Szwed, Hanna

    2016-01-01

    Cardiovascular implantable electronic device (CIED) infection is a complication of increasing incidence. We present a protocol of an observational case control clinical trial "Positron Emission Tomography Combined With Computed Tomography (PET CT) in Suspected Cardiac Implantable Electronic Device Infection, a Pilot Study - PET Guidance I" (NCT02196753). The aim of this observational clinical trial is to assess and standardise diagnostic algorithms for CIED infections (lead-dependent infective endocarditis, generator pocket infection, fever of unknown origin) with PET CT in Poland. Study group will consist of 20 patients with initial diagnosis of CIED-related infection paired with a control group of 20 patients with implanted CIEDs, who underwent PET CT due to other non-infectious indications and have no data for infectious process in follow-up. All patients included in the study will undergo standard diagnostic pro-cess. Conventional/standard diagnostic and therapeutic process will consist of: medical interview, physical examination, laboratory tests, blood cultures; imaging studies: echocardiography: transthoracic (TTE), and, if there are no contraindications transoesophageal, computed tomography scan for pulmonary embolism if indicated; if there are abnormalities in other systems, decisions concerning further diagnostics will be made at the physician's discretion. As well as standard diagnostic procedures, patients will undergo whole body PET CT scan to localise infection or inflammation. Diagnosis and therapeutic decision will be obtained from the Study Committee. Follow-up will be held within six months with control visits at three and six months. During each follow-up visit, all patients will undergo laboratory tests, two blood cultures collected 1 h apart, and TTE. In case of actual clinical suspicion of infective endocarditis or local generator pocket infection, patients will be referred for further diagnostics. Endpoints for the results assessment - primary endpoints are to standardise PET CT in the diagnostic process: sensitivity, specificity, positive predictive value, and negative predictive value of the diagnosis made by PET CT; secondary endpoints are: assessment of usefulness of PET CT for detection of remote infective complications (metastatic abscesses, infected pulmonary emboli), incidence of particular localisations of infection, influence of PET CT on therapeutic decision: confirmation or change of decision based on PET CT, safety and complications of diagnostic process of CIED-related infections with PET CT. Evaluation of PET CT use for device-related infections in a case control study may be conclusive and improve diagnostic pathway.

  4. Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference.

    PubMed

    Suh, Young Joo; Lee, Sak; Im, Dong Jin; Chang, Suyon; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Choi, Byoung Wook; Chang, Byung-Chul; Shim, Chi Young; Hong, Geu-Ru; Kim, Young Jin

    2016-07-01

    The added value of cardiac computed tomography (CT) with transesophageal echocardiography (TEE) for evaluating mechanical aortic valve (AV) dysfunction has not yet been investigated. The purposes of this study were to investigate the added value of cardiac CT for evaluation of mechanical AVs and diagnoses of pannus compared to TEE, with surgical findings of redo-aortic valve replacement (AVR) used as a standard reference. 25 patients who underwent redo-AVR due to mechanical AV dysfunction and cardiac CT before redo-AVR were included. The presence of pannus, encroachment ratio by pannus, and limitation of motion (LOM) were evaluated on CT. The diagnostic performance of pannus detection was compared using TEE, CT, and CT+TEE, with surgical findings as a standard reference. The added value of CT for diagnosing the cause of mechanical AV dysfunction was assessed compared to TTE+TEE. In two patients, CT analysis was not feasible due to severe metallic artifacts. On CT, pannus and LOM were found in 100% (23/23) and 60.9% (14/23). TEE identified pannus in 48.0% of patients (12/25). CT, TEE, and CT+TEE correctly identified pannus with sensitivity of 92.0%, 48.0%, and 92.0%, respectively (P=0.002 for CT vs. TEE). In 11 of 13 cases (84.6%) with inconclusive or negative TEE results for pannus, CT detected the pannus. Among 13 inconclusive cases of TTE+TEE for the cause of mechanical AV dysfunction, CT suggested 6 prosthetic valve obstruction (PVO) by pannus, 4 low-flow low-gradient PVO, and one LOM without significant PVO. Cardiac CT showed added diagnostic value with TEE in the detection of pannus as the cause of mechanical AV dysfunction. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Predicting need for additional CT scan in children with a non-diagnostic ultrasound for appendicitis in the emergency department.

    PubMed

    Nishizawa, Takuya; Maeda, Shigenobu; Goldman, Ran D; Hayashi, Hiroyuki

    2018-01-01

    This study aimed to determine which children with suspected appendicitis should be considered for a computerized tomography (CT) scan after a non-diagnostic ultrasound (US) in the Emergency Department (ED). We retrospectively reviewed patients 0-18year old, who presented to the ED with complaints of abdominal pain, during 2011-2015 and while in the hospital had both US and CT. We recorded demographic and clinical data and outcomes, and used univariate and multivariate methods for comparing patients who did and didn't have appendicitis on CT after non-diagnostic US. Multivariate analysis was performed using logistic regression to determine what variables were independently associated with appendicitis. A total of 328 patients were enrolled, 257 with non-diagnostic US (CT: 82 had appendicitis, 175 no-appendicitis). Younger children and those who reported vomiting or had right lower abdominal quadrant (RLQ) tenderness, peritoneal signs or White Blood Cell (WBC) count >10,000 in mm 3 were more likely to have appendicitis on CT. RLQ tenderness (Odds Ratio: 2.84, 95%CI: 1.07-7.53), peritoneal signs (Odds Ratio: 11.37, 95%CI: 5.08-25.47) and WBC count >10,000 in mm 3 (Odds Ratio: 21.88, 95%CI: 7.95-60.21) remained significant after multivariate analysis. Considering CT with 2 or 3 of these predictors would have resulted in sensitivity of 94%, specificity of 67%, positive predictive value of 57% and negative predictive value of 96% for appendicitis. Ordering CT should be considered after non-diagnostic US for appendicitis only when children meet at least 2 predictors of RLQ tenderness, peritoneal signs and WBC>10,000 in mm 3 . Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Diagnostic value of imaging in infective endocarditis: a systematic review.

    PubMed

    Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu

    2017-01-01

    Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review to critically appraise the evidence for the diagnostic performance of these imaging modalities, according to PRISMA and GRADE criteria. We searched PubMed, Embase, and Cochrane databases. 31 studies were included that presented original data on the performance of electrocardiogram (ECG)-gated multidetector CT angiography (MDCTA), ECG-gated MRI, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET/CT, and leucocyte scintigraphy in diagnosis of native valve endocarditis, intracardiac prosthetic material-related infection, and extracardiac foci in adults. We consistently found positive albeit weak evidence for the diagnostic benefit of 18 F-FDG PET/CT and MDCTA. We conclude that additional imaging techniques should be considered if infective endocarditis is suspected. We propose an evidence-based diagnostic work-up for infective endocarditis including these non-invasive techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Predictors and Diagnostic Significance of the Adenosine Related Side Effects on Myocardial Perfusion SPECT/CT Imaging

    PubMed Central

    Yıldırım Poyraz, Nilüfer; Özdemir, Elif; Poyraz, Barış Mustafa; Kandemir, Zuhal; Keskin, Mutlay; Türkölmez, Şeyda

    2014-01-01

    Objective: The aim of this study was to investigate the relationship between patient characteristics and adenosine-related side-effects during stress myocard perfusion imaging (MPI). The effect of presence of adenosine-related side-effects on the diagnostic value of MPI with integrated SPECT/CT system for coronary artery disease (CAD), was also assessed in this study. Methods: Total of 281 patients (109 M, 172 F; mean age:62.6±10) who underwent standard adenosine stress protocol for MPI, were included in this study. All symptoms during adenosine infusion were scored according to the severity and duration. For the estimation of diagnostic value of adenosine MPI with integrated SPECT/CT system, coronary angiography (CAG) or clinical follow-up were used as gold standard. Results: Total of 173 patients (61.6%) experienced adenosine-related side-effects (group 1); flushing, dyspnea, and chest pain were the most common. Other 108 patients completed pharmacologic stress (PS) test without any side-effects (group 2). Test tolerability were similar in the patients with cardiovascular or airway disease to others, however dyspnea were observed significantly more common in patients with mild airway disease. Body mass index (BMI) ≥30 kg/m2 and age ≤45 years were independent predictors of side-effects. The diagnostic value of MPI was similar in both groups. Sensitivity of adenosine MPI SPECT/CT was calculated to be 86%, specificity was 94% and diagnostic accuracy was 92% for diagnosis of CAD. Conclusion: Adenosine MPI is a feasible and well tolerated method in patients who are not suitable for exercise stress test as well as patients with cardiopulmonary disease. However age ≤45 years and BMI ≥30 kg/m2 are the positive predictors of adenosine-related side-effects, the diagnostic value of adenosine MPI SPECT/CT is not affected by the presence of adenosine related side-effects. PMID:25541932

  8. The diagnostic performance and added value of (18)F-FDG PET/CT in the detection of liver metastases in recurrent colorectal carcinoma patients.

    PubMed

    Odalovic, Strahinja; Artiko, Vera; Sobic-Saranovic, Dragana; Stojiljkovic, Milica; Petrovic, Milorad; Petrovic, Nebojsa; Kozarevic, Nebojsa; Grozdic-Milojevic, Isidora; Obradovic, Vladimir

    2015-01-01

    The aim of this study was to assess the value of (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT in detection of liver metastases in patients with suspected recurrent colorectal carcinoma, as well as to compare diagnostic performance of (18)F-FDG PET/CT with conventional imaging methods (MDCT). This study included 73 patients with resected primary colorectal adenocarcinoma referred for (18)F-FDG PET/CT to the National PET Center, at the Clinical Center of Serbia, Belgrade, from January 2010 to May 2013, with suspicion of recurrence. The patients underwent (18)F-FDG PET/CT examination on a 64-slice hybrid PET/CT scanner (Biograph, TruePoint64, Siemens Medical Solutions, Inc. USA). Prior to (18)F-FDG PET/CT all patients underwent contrast-enhanced MDCT. Findings of (18)F-FDG PET/CT and MDCT were compared to findings of subsequent histopathological examinations or with results of clinical and imaging follow-up over at least six months. Final diagnosis of liver metastases of colorectal cancer was made either by histopathological examination of specimen after biopsy or surgery, or based on clinical, laboratory and imaging evaluation during first six months after PET/CT scan. In detection of liver metastases (18)F-FDG PET/CT showed sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 83.3%, 95.3%, 92.6%, 89.1% and 90.4%, respectively. In addition, MDCT showed sensitivity, specificity, positive predictive value, negative predictive value and accuracy in detection of liver metastases of 60%, 88.4%, 78.3%, 76% and 76.7%, respectively. There was significant difference in sensitivity (83.3% vs 60%; P=0.045) between these two methods. In addition, significant difference was observed in accuracy between PET/CT and MDCT (90.4% vs 76.7%; P=0.016). The higher specificity in visualization of liver metastases was also achieved by (18)F-FDG PET/CT compared to MDCT (95.3% vs 88.4%), but this difference was not significant (P=0.37). (18)F-FDG PET/CT was highly sensitive, specific and accurate method in detection of liver metastases in patients with suspected recurrent colorectal carcinoma in our study. This hybrid imaging showed superior diagnostic performance in evaluation of suspected colorectal cancer liver metastases compared to conventional imaging.

  9. Evaluation of lymph node status after neoadjuvant chemotherapy in breast cancer patients: comparison of diagnostic performance of ultrasound, MRI and ¹⁸F-FDG PET/CT.

    PubMed

    You, S; Kang, D K; Jung, Y S; An, Y-S; Jeon, G S; Kim, T H

    2015-08-01

    To evaluate the diagnostic performance of ultrasound, MRI and fluorine-18 fludeoxyglucose positron emission tomography (¹⁸F-FDG PET)/CT for the diagnosis of metastatic axillary lymph node (ALN) after neoadjuvant chemotherapy (NAC) and to find out histopathological factors affecting the diagnostic performance of these imaging modalities. From January 2012 to November 2014, 191 consecutive patients with breast cancer who underwent NAC before surgery were retrospectively reviewed. We included 139 patients with ALN metastasis that was confirmed on fine needle aspiration or core needle biopsy at initial diagnosis. After NAC, 39 (28%) patients showed negative conversion of ALN on surgical specimens of sentinel lymph node (LN) or ALN. The sensitivity of ultrasound, MRI and PET/CT was 50% (48/96), 72% (70/97) and 22% (16/73), respectively. The specificity of ultrasound, MRI and PET/CT was 77% (30/39), 54% (21/39) and 85% (22/26), respectively. The Az value of combination of ultrasound and PET/CT was the highest (0.634) followed by ultrasound (0.626) and combination of ultrasound, MRI and PET/CT (0.617). The size of tumour deposit in LN and oestrogen receptor was significantly associated with the diagnostic performance of ultrasound (p < 0.001 and p = 0.009, respectively) and MRI (p = 0.045 and p = 0.036, respectively). The percentage diameter decrease, size of tumour deposit in LN, progesterone receptor, HER2 and histological grade were significantly associated with the diagnostic performance of PET/CT (p = 0.023, p = 0.002, p = 0.036, p = 0.044 and p = 0.008, respectively). On multivariate logistic regression analysis, size of tumour deposit within LN was identified as being independently associated with diagnostic performance of ultrasound [odds ratio, 13.07; 95% confidence interval (CI), 2.95-57.96] and PET/CT (odds ratio, 6.47; 95% CI, 1.407-29.737). Combination of three imaging modalities showed the highest sensitivity, and PET/CT showed the highest specificity for the evaluation of ALN metastasis after NAC. Ultrasound alone or combination of ultrasound and PET/CT showed the highest positive-predictive value. The size of tumour deposit within ALN was significantly associated with diagnostic performance of ultrasound and PET/CT. This study is about the diagnostic performance of ultrasound, MRI, PET/CT and combination of each imaging modality for the evaluation of metastatic ALN after NAC. Of many histopathological factors, only the size of tumour deposit within ALN was an independent factor associated with the diagnostic performance of ultrasound and PET/CT.

  10. Worsening respiratory function in mechanically ventilated intensive care patients: feasibility and value of xenon-enhanced dual energy CT.

    PubMed

    Hoegl, Sandra; Meinel, Felix G; Thieme, Sven F; Johnson, Thorsten R C; Eickelberg, Oliver; Zwissler, Bernhard; Nikolaou, Konstantin

    2013-03-01

    To evaluate the feasibility and incremental diagnostic value of xenon-enhanced dual-energy CT in mechanically ventilated intensive care patients with worsening respiratory function. The study was performed in 13 mechanically ventilated patients with severe pulmonary conditions (acute respiratory distress syndrome (ARDS), n=5; status post lung transplantation, n=5; other, n=3) and declining respiratory function. CT scans were performed using a dual-source CT scanner at an expiratory xenon concentration of 30%. Both ventilation images (Xe-DECT) and standard CT images were reconstructed from a single CT scan. Findings were recorded for Xe-DECT and standard CT images separately. Ventilation defects on xenon images were matched to morphological findings on standard CT images and incremental diagnostic information of xenon ventilation images was recorded if present. Mean xenon consumption was 2.95 l per patient. No adverse events occurred under xenon inhalation. In the visual CT analysis, the Xe-DECT ventilation defects matched with pathologic changes in lung parenchyma seen in the standard CT images in all patients. Xe-DECT provided additional diagnostic findings in 4/13 patients. These included preserved ventilation despite early pneumonia (n=1), more confident discrimination between a large bulla and pneumothorax (n=1), detection of an airway-to-pneumothorax fistula (n=1) and exclusion of a suspected airway-to-mediastinum fistula (n=1). In all 4 patients, the additional findings had a substantial impact on patients' management. Xenon-enhanced DECT is safely feasible and can add relevant diagnostic information in mechanically ventilated intensive care patients with worsening respiratory function. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. [Diagnostic values of bronchoscopy and multi-slice spiral CT for congenital dysplasia of the respiratory system in infants: a comparative study].

    PubMed

    Wang, Xing-Lu; Huang, Ying; Li, Qu-Bei; Dai, Ji-Hong

    2013-09-01

    To investigate and compare the diagnostic values of bronchoscopy and multi-slice spiral computed tomography (CT) for congenital dysplasia of the respiratory system in infants. Analysis was performed on the clinical data, bronchoscopic findings and multi-slice spiral CT findings of 319 infants (≤1 years old) who underwent bronchoscopy and/or multi-slice spiral CT and were diagnosed with congenital dysplasia of the respiratory system. A total of 476 cases of congenital dysplasia of the respiratory system were found in the 319 infants, including primary dysplasia of the respiratory system (392 cases) and compressive dysplasia of the respiratory system (84 cases). Of the 392 cases of primary dysplasia of the respiratory system, 225 (57.4%) were diagnosed by bronchoscopy versus 167 (42.6%) by multi-slice spiral CT. There were significant differences in etiological diagnosis between bronchoscopy and multi-slice spiral CT in infants with congenital dysplasia of the respiratory system (P<0.05). All 76 cases of primary dysplasia of the respiratory system caused by tracheobronchomalacia were diagnosed by bronchoscopy and all 17 cases of primary dysplasia of the respiratory system caused by lung tissue dysplasia were diagnosed by multi-slice spiral CT. Of the 84 cases of compressive dysplasia of the respiratory system, 74 cases were diagnosed by multi-slice spiral CT and only 10 cases were diagnosed by bronchoscopy. Compared with multi-slice spiral CT, bronchoscopy can detect primary dysplasia of the respiratory system more directly. Bronchoscopy is valuable in the confirmed diagnosis of tracheobronchomalacia. Multi-slice spiral CT has a higher diagnostic value for lung tissue dysplasia than bronchoscopy.

  12. Effect of slice thickness on image noise and diagnostic content of single-source-dual energy computed tomography

    NASA Astrophysics Data System (ADS)

    Alshipli, Marwan; Kabir, Norlaili A.

    2017-05-01

    Computed tomography (CT) employs X-ray radiation to create cross-sectional images. Dual-energy CT acquisition includes the images acquired from an alternating voltage of X-ray tube: a low- and a high-peak kilovoltage. The main objective of this study is to determine the best slice thickness that reduces image noise with adequate diagnostic information using dual energy CT head protocol. The study used the ImageJ software and statistical analyses to aid the medical image analysis of dual-energy CT. In this study, ImageJ software and F-test were utilised as the combination methods to analyse DICOM CT images. They were used to investigate the effect of slice thickness on noise and visibility in dual-energy CT head protocol images. Catphan-600 phantom was scanned at different slice thickness values;.6, 1, 2, 3, 4, 5 and 6 mm, then quantitative analyses were carried out. The DECT operated in helical mode with another fixed scan parameter values. Based on F-test statistical analyses, image noise at 0.6, 1, and 2 mm were significantly different compared to the other images acquired at slice thickness of 3, 4, 5, and 6 mm. However, no significant differences of image noise were observed at 3, 4, 5, and 6 mm. As a result, better diagnostic image value, image visibility, and lower image noise in dual-energy CT head protocol was observed at a slice thickness of 3 mm.

  13. Assessing the role of 18F-FDG PET and 18F-FDG PET/CT in the diagnosis of soft tissue musculoskeletal malignancies – A systematic review and meta-analysis

    PubMed Central

    Etchebehere, Elba C.; Hobbs, Brian P.; R.Milton, Denái; Malawi, Osama; Patel, Shreyaskumar; Benjamin, Robert S.; Macapinlac, Homer A.

    2016-01-01

    Purpose Twelve years ago a meta-analysis evaluated the diagnostic performance of 18F-FDG PET in assessing musculoskeletal soft tissue lesions (MsSTL). Currently, PET/CT has substituted PET imaging however there has not been any published meta-analysis on the use of PET/CT or a comparison of PET/CT with PET in the diagnosis of MsSTL. Therefore, we conducted a meta-analysis to identify the current diagnostic performance of 18F-FDG PET/CT and determine if there is added value when compared to PET. Patients and Methods A systematic review of English articles using MEDLINE PubMed, the Cochrane Library and EMBASE were searched from 1996 to March 2015. Studies exploring the diagnostic accuracy of 18F-FDG PET/CT (or dedicated PET) compared to histopathology in patients with MsSTL undergoing investigation for malignancy were included. Results Our meta-analysis included 14 articles composed of 755 patients with 757 soft tissue lesions. There were 451 (60%) malignant tumors and 306 benign lesions. The 18F-FDG PET/CT (and dedicated PET) mean sensitivity, specificity, accuracy, positive and negative predictive values for diagnosing MsSTL was 0.96 (0.90, 1.00), 0.77 (0.67, 0.86), 0.88 (0.85, 0.91), 0.86 (0.78, 0.94) and 0.91 (0.83, 0.99), respectively. The posterior mean (95% HPD interval) for the AUC was 0.92 (0.88, 0.96). PET/CT had higher specificity, accuracy and positive predictive value when compared to a dedicated PET (0.85, 0.89 and 0.91 vs 0.71, 0.85 and 0.82, respectively). Conclusions 18F-FDG PET/CT and dedicated PET are both highly accurate in the diagnosis of MsSTL. PET/CT is more accurate, specific and has a higher positive predictive value than PET. PMID:26631240

  14. Lung malignancy: Diagnostic accuracies of bronchoalveolar lavage, bronchial brushing, and fine needle aspiration cytology

    PubMed Central

    Sareen, Rateesh; Pandey, C L

    2016-01-01

    Background: Early diagnosis of lung cancer plays a pivotal role in reducing lung cancer death rate. Cytological techniques are safer, economical and provide quick results. Bronchoscopic washing, brushing and fine needle aspirations not only complement tissue biopsies in the diagnosis of lung cancer but also comparable. Objectives: (1) To find out diagnostic yields of bronchioalveolar lavage, bronchial brushings, FNAC in diagnosis of lung malignancy. (2) To compare relative accuracy of these three cytological techniques. (3) To correlate the cytologic diagnosis with clinical, bronchoscopic and CT findings. (4) Cytological and histopathological correlation of lung lesions. Methods: All the patients who came with clinical or radiological suspicion of lung malignancy in two and a half year period were included in study. Bronchoalveolar lavage was the most common type of cytological specimen (82.36%), followed by CT guided FNAC (9.45%) and bronchial brushings (8.19%). Sensitivity, specificity, positive and negative predictive value for all techniques and correlation with histopathology was done using standard formulas. Results: The most sensitive technique was CT FNAC – (87.25%) followed by brushings (77.78%) and BAL (72.69%). CT FNAC had highest diagnostic yield (90.38%), followed by brushings (86.67%) and BAL (83.67%). Specificity and positive predictive value were 100 % each of all techniques. Lowest false negatives were obtained in CT FNAC (12.5%) and highest in BAL (27.3%). Highest negative predictive value was of BAL 76.95 % followed by BB 75.59% and CT FNAC 70.59%. Conclusion: Before administering antitubercular treatment every effort should be made to rule out malignancy. CT FNAC had highest diagnostic yield among three cytological techniques. BAL is an important tool in screening central as well as in accessible lesions. It can be used at places where CT guided FNAC is not available or could not be done due to technical or financial limitations PMID:27890992

  15. The Role of Computed Tomography in Blunt Abdominal Trauma.

    PubMed

    Karki, O B

    2015-01-01

    Blunt injury trauma is regularly encountered in the emergency department. Diagnostic tools that help in optimum management of blunt abdominal trauma include; Focussed Assessment Sonography for Trauma scan, Diagnostic peritoneal lavage and Computed Tomography scan. The aim of this study is to determine the validity of CT scan as an accurate diagnostic tool and its role in management of patients with blunt abdominal trauma. A prospective analysis of 80 patients of blunt abdomen trauma who were admitted in Manipal Teaching Hospital, Pokhara, Nepal within a span of 15 months was done. Demographic data, mechanism of trauma, management and outcomes were studied. Organ injuries were graded using the Organ Injury Scale guidelines. Most of the patients in our study were in the age group of 21-40 years with an M: F ratio of 2.3:1. Road traffic accident (47.5%) was the most common mechanism of injury. Spleen (27.5%) was the commonest organ injured. CT scan was superior to FAST scan and had sensitivity of 97.3% specificity 75% positive predictive value 98.6%. FAST scan had sensitivity of 78.9%, specificity 50%, positive predictive value 96% with p- value of 0.0034. 81% of patients were conservatively managed. In conjunction with close clinical monitoring, CT scan is reliable in the evaluation and management of blunt abdominal trauma patients. Our study also shows CT as a superior diagnostic modality compared to FAST scan.

  16. Congenital Adrenal Neuroblastoma With and Without Cystic Change: Differentiating Features With an Emphasis on the of Value of Ultrasound.

    PubMed

    Hwang, Sook Min; Yoo, So-Young; Kim, Ji Hye; Jeon, Tae Yeon

    2016-11-01

    The purpose of this study was to compare the features of congenital adrenal neuroblastomas with and without cystic changes and to emphasize the value of ultrasound in the diagnostic evaluation of cystic congenital adrenal neuroblastoma. A total of 41 patients with surgically confirmed congenital adrenal neuroblastoma were enrolled. We divided the patients into two groups according to presence or absence of cystic change in the tumor, as determined from the initial ultrasound findings. Clinical and laboratory findings, disease stage, and patient outcome were investigated with a statistical comparison between the two groups. The imaging findings for cystic congenital adrenal neuroblastoma were reviewed to compare the additional diagnostic value of CT and MRI when paired with ultrasound. There were 22 patients (54%) in the group without cystic changes and 19 patients (46%) in the group with cystic changes. Prenatal detection and absence of metastasis were significantly more common in the cystic group than in the noncystic group (p < 0.05). Sensitivities of tumor marker levels were also significantly lower in the cystic group. Patient outcome was excellent, and there was no significant difference between the groups. With regard to imaging of cystic congenital adrenal neuroblastoma, in the 15 cases in which CT or MRI was paired with ultrasound, no additional diagnostic information was discerned with CT or MRI. Nearly one-half of congenital adrenal neuroblastomas are cystic, and these tumors have clinical and laboratory features that distinguish them from noncystic congenital adrenal neuroblastoma. Diagnostic tests, including CT, MRI, and assessment of tumor markers, have low diagnostic value in the evaluation of cystic congenital adrenal neuroblastoma.

  17. Molecular imaging of malignant tumor metabolism: whole-body image fusion of DWI/CT vs. PET/CT.

    PubMed

    Reiner, Caecilia S; Fischer, Michael A; Hany, Thomas; Stolzmann, Paul; Nanz, Daniel; Donati, Olivio F; Weishaupt, Dominik; von Schulthess, Gustav K; Scheffel, Hans

    2011-08-01

    To prospectively investigate the technical feasibility and performance of image fusion for whole-body diffusion-weighted imaging (wbDWI) and computed tomography (CT) to detect metastases using hybrid positron emission tomography/computed tomography (PET/CT) as reference standard. Fifty-two patients (60 ± 14 years; 18 women) with different malignant tumor disease examined by PET/CT for clinical reasons consented to undergo additional wbDWI at 1.5 Tesla. WbDWI was performed using a diffusion-weighted single-shot echo-planar imaging during free breathing. Images at b = 0 s/mm(2) and b = 700 s/mm(2) were acquired and apparent diffusion coefficient (ADC) maps were generated. Image fusion of wbDWI and CT (from PET/CT scan) was performed yielding for wbDWI/CT fused image data. One radiologist rated the success of image fusion and diagnostic image quality. The presence or absence of metastases on wbDWI/CT fused images was evaluated together with the separate wbDWI and CT images by two different, independent radiologists blinded to results from PET/CT. Detection rate and positive predictive values for diagnosing metastases was calculated. PET/CT examinations were used as reference standard. PET/CT identified 305 malignant lesions in 39 of 52 (75%) patients. WbDWI/CT image fusion was technically successful and yielded diagnostic image quality in 73% and 92% of patients, respectively. Interobserver agreement for the evaluation of wbDWI/CT images was κ = 0.78. WbDWI/CT identified 270 metastases in 43 of 52 (83%) patients. Overall detection rate and positive predictive value of wbDWI/CT was 89% (95% CI, 0.85-0.92) and 94% (95% CI, 0.92-0.97), respectively. WbDWI/CT image fusion is technically feasible in a clinical setting and allows the diagnostic assessment of metastatic tumor disease detecting nine of 10 lesions as compared with PET/CT. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  18. Diagnostic value of a pancreatic mass on computed tomography in patients undergoing pancreatoduodenectomy for presumed pancreatic cancer.

    PubMed

    Gerritsen, Arja; Bollen, Thomas L; Nio, C Yung; Molenaar, I Quintus; Dijkgraaf, Marcel G W; van Santvoort, Hjalmar C; Offerhaus, G Johan; Brosens, Lodewijk A; Biermann, Katharina; Sieders, Egbert; de Jong, Koert P; van Dam, Ronald M; van der Harst, Erwin; van Goor, Harry; van Ramshorst, Bert; Bonsing, Bert A; de Hingh, Ignace H; Gerhards, Michael F; van Eijck, Casper H; Gouma, Dirk J; Borel Rinkes, Inne H M; Busch, Olivier R C; Besselink, Marc G H

    2015-07-01

    Previous studies have shown that 5-14% of patients undergoing pancreatoduodenectomy for suspected malignancy ultimately are diagnosed with benign disease. A "pancreatic mass" on computed tomography (CT) is considered to be the strongest predictor of malignancy, but studies describing its diagnostic value are lacking. The aim of this study was to determine the diagnostic value of a pancreatic mass on CT in patients with presumed pancreatic cancer, as well as the interobserver agreement among radiologists and the additional value of reassessment by expert-radiologists. Reassessment of preoperative CT scans was performed within a previously described multicenter retrospective cohort study in 344 patients undergoing pancreatoduodenectomy for suspected malignancy (2003-2010). Preoperative CT scans were reassessed by 2 experienced abdominal radiologists separately and subsequently in a consensus meeting, after defining a pancreatic mass as "a measurable space occupying soft tissue density, except for an enlarged papilla or focal steatosis". CT scans of 86 patients with benign and 258 patients with (pre)malignant disease were reassessed. In 66% of patients a pancreatic mass was reported in the original CT report, versus 48% and 50% on reassessment by the 2 expert radiologists separately and 44% in consensus (P < .001 vs original report). Interobserver agreement between the original CT report and expert consensus was fair (kappa = 0.32, 95% confidence interval 0.23-0.42). Among both expert-radiologists agreement was moderate (kappa = 0.47, 95% confidence interval 0.38-0.56), with disagreement on the presence of a pancreatic mass in 29% of cases. The specificity for malignancy of pancreatic masses identified in expert consensus was twice as high compared with the original CT report (87% vs 42%, respectively). Positive predictive value increased to 98% after expert consensus, but negative predictive value was low (12%). Clinicians need to be aware of potential considerable disagreement among radiologists about the presence of a pancreatic mass. The specificity for malignancy doubled by expert radiologist reassessment when a uniform definition of "pancreatic mass" was used. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. [The role of preoperative (18)F-FDG PET-CT in lymphatic metastasis diagnosis of cutaneous malignant melanoma on extremities and trunk].

    PubMed

    Zhang, X X; Fang, Y; Xu, L B; Xu, S F; Zhao, Z G; Sun, C; Ma, P Q; Liu, T; Yu, S J; Zhang, W J

    2018-05-23

    Objective: To evaluate the clinical value of preoperative (18)F-Fludeoxyglucose ((18)F-FDG PET-CT) in lymphatic metastasis diagnosis of cutaneous melanoma on extremities and trunk. Methods: 112 patients with cutaneous melanoma pathologically of extremities and trunk from January 2006 to December 2016, who received (18)F-FDG PET-CT examination preoperatively, were retrospectively reviewed. The correlations between the maximal diameters of lymph nodes, the maximal standard uptake value (SUV) and the diagnostic impression grades of PET-CT examination, and the final pathological diagnosis were analyzed. The correlations between Breslow thickness of primary lesions and the diagnostic impression of PET-CT examination were also analyzed. All the above were analyzed with Receiver Operating Characteristic (ROC) curve to get the cut-off value. Based on the final results of pathological diagnosis of lymph nodes as the golden standard, the statistically significant indicators of ROC curve analysis were used to evaluate the diagnostic effect, as well as to calculate the sensitivity, specificity and accuracy. With gender, age, maximal diameter of lymph nodes, maximal SUV, diagnosis impressions, and Breslow thickness as the independent variables and pathological diagnosis results of lymph nodes as the dependent variable, two-class stepwise Logistic regression analysis was used to determine the independence of diagnostic indicators. ROC curve analysis and log rank test were used to analyze the relationship between Breslow thickness and patient survival. Results: To evaluate melanoma patients' lymph node status, the results of ROC curve analysis showed that the area under the curve of lymph node maximal diameter, maximal SUV, diagnosis impression of PET-CT examinations were 0.789, 0.786 and 0.816, respectively (all P <0.05). The cut-off values were 0.85 cm, 1.45 and 2.5, respectively. The sensitivity of the cut-off values to determine the status of lymph nodes in melanoma patients were 71.4%, 64.9% and 72.1% respectively, and the specificities were 85.2%, 88.7% and 87.0% respectively. Multivariate Logistic regression analysis showed that PET-CT diagnosis impressions had independent diagnostic significance for the lymph node status of melanoma patients ( OR =11.296, 95% CI : 2.550~50.033). The area under the curve of Breslow thickness evaluating PET-CT diagnostic impression is 0.664 ( P =0.042) and the cut-off value was 4.25 mm. The survival rate of the patients with Breslow thickness ≥ 4.25 mm was lower than that in the group <4.25 mm ( P =0.006). Conclusions: (18)F-FDG PET-CT can help to evaluate metastases and make treatment decisions for cutaneous melanoma of extremities and trunk, especially for patients whose primary lesion's Breslow thickness has reached more than 4.25 mm. For the patients whose maximal SUV of regional lymph node is higher than 1.45 and short diameter of the largest lymph node is larger than 0.85cm, the possibility of metastases should be considered.

  20. How to create a cardiac CT clinic.

    PubMed

    Dowe, David A

    2007-02-01

    Coronary computed tomography (CT) angiography is taking an exponentially increasing role in the diagnostic algorithm of suspected coronary artery disease. It has the immediate potential of replacing stress tests as the first study a patient receives if suspected of having coronary artery disease. In the near future, it will likely precede all elective, diagnostic cardiac catheterizations secondary to its extraordinary negative predictive value. This paper discusses the 3 building blocks of a successful cardiac CT clinic, image quality, service, and marketing. It then discusses the significant differences in establishing a cardiac CT clinic depending on if the radiologist is hospital based or private office based.

  1. [Diagnostic value of (18)F-FDG PET/CT for solitary nodular-type bronchoalveolar carcinoma].

    PubMed

    Liu, Weikun; Li, Xiangdong; Quan, Jiangtao; Ouyang, Xi; Zheng, Hui

    2013-01-01

    To assess the value of (18)F-FDG PET/CT in the diagnosis of solitary nodular-type bronchoalveolar carcinoma (BAC). The clinical and radiographic data were analyzed retrospectively in 30 patients with pathologically confirmed solitary nodular-type BAC who underwent (18)F-FDG PET/CT examinations between August, 2005 and December, 2006. The morphological and radioactive findings of the lesions were reviewed, and the maximum standard uptake values (SUVmax) were measured. The diagnostic accuracy of PET, PET/CT, and HRCT were analyzed. The (18)F-FDG SUV was markedly lower in BAC than in other well differentiated adenocarcinoma. In 19 of the BAC cases, PET showed a SUVmax of no less than 2.5, demonstrating positive changes. Of the total of 30 cases, 5 had ground glass opacity (GGO) changes, 3 exhibited mixed nodules with GGO changes around the lesions, and 22 cases presented with solid nodules. HRCT showed that BAC located often in the superior lobes of the bilateral lungs, mostly below the pleura in the surrounding lung field; the lesions were patchy or nodular with irregular shapes, showing lobulation in 22 cases, spiculation in 15 cases, pleural indentation in 21 cases, and vacuolar changes in 4 cases. The diagnostic accuracy of PET, PET/CT and HRCT for solitary nodular-type BAC was 36.67%, 93.33%, and 93.33%, respectively. The SUVmax of BAC provides only limited value for defining the nature of the lesions, but can serve as a general reference for assessing the disease activity. PET/CT, which allows both functional and imaging assessment, can be a valuable modality to reduce the misdiagnosis rate of BAC.

  2. [Diagnostic value of (18)F-FDG PET/CT for solitary nodular-type bronchoalveolar carcinoma].

    PubMed

    Liu, Wei-Kun; Li, Xiang-Dong; Quan, Jiang-Tao; Ouyang, Xi; Zheng, Hui

    2015-01-01

    To assess the value of (18)F-FDG PET/CT in the diagnosis of solitary nodular-type bronchoalveolar carcinoma (BAC). The clinical and radiographic data were analyzed retrospectively in 30 patients with pathologically confirmed solitary nodular-type BAC who underwent (18)F-FDG PET/CT examinations between August, 2005 and December, 2006. The morphological and radioactive findings of the lesions were reviewed, and the maximum standard uptake values (SUVmax) were measured. The diagnostic accuracy of PET, PET/CT, and HRCT were analyzed. The (18)F-FDG SUV was markedly lower in BAC than in other well differentiated adenocarcinoma. In 19 of the BAC cases, PET showed a SUVmax of no less than 2.5, demonstrating positive changes. Of the total of 30 cases, 5 had ground glass opacity (GGO) changes, 3 exhibited mixed nodules with GGO changes around the lesions, and 22 cases presented with solid nodules. HRCT showed that BAC located often in the superior lobes of the bilateral lungs, mostly below the pleura in the surrounding lung field; the lesions were patchy or nodular with irregular shapes, showing lobulation in 22 cases, spiculation in 15 cases, pleural indentation in 21 cases, and vacuolar changes in 4 cases. The diagnostic accuracy of PET, PET/CT and HRCT for solitary nodular-type BAC was 36.67%, 93.33%, and 93.33%, respectively. The SUVmax of BAC provides only limited value for defining the nature of the lesions, but can serve as a general reference for assessing the disease activity. PET/CT, which allows both functional and imaging assessment, can be a valuable modality to reduce the misdiagnosis rate of BAC.

  3. Diagnostic value of chest radiographs in bedridden patients suspected of having pneumonia.

    PubMed

    Esayag, Yaacov; Nikitin, Irina; Bar-Ziv, Jacob; Cytter, Ruth; Hadas-Halpern, Irith; Zalut, Todd; Yinnon, Amos M

    2010-01-01

    To assess the diagnostic value of the chest radiograph for the diagnosis of pneumonia in bedridden patients, using non-contrast-enhanced high-resolution chest computed tomography (CT) as the gold standard. We prospectively evaluated bedridden patients hospitalized with moderate to high clinical probability of pneumonia. Chest radiographs were interpreted in a blinded fashion by 3 observers and classified as definite, normal, or uncertain for pneumonia. Chest CT was obtained within 12 hours of chest radiograph. We applied Bayesian analysis to assess the accuracy of chest radiograph in the diagnosis of pneumonia. In a 5-month period, 58 patients were evaluated, 31 (53%) were female. Their chest radiographs were interpreted as negative, uncertain, or positive for pneumonia in 31 (53%), 15 (26%), and 12 (21%) patients, respectively, while CT confirmed pneumonia in 11 (35%), 10 (67%), and in 10 (83%). The sensitivity of the chest radiograph to diagnose pneumonia was 65%, the specificity was 93%, the positive and negative predictive values were, respectively, 83% and 65%, while the overall accuracy was 69% (95% confidence interval, 50%-79%). In bedridden patients with suspected pneumonia, a normal chest radiograph does not rule out the diagnosis, hence, a chest CT scan might provide valuable diagnostic information. Copyright 2010 Elsevier Inc. All rights reserved.

  4. [The role of ¹⁸F-FDG PET/CT for detecting nodal metastases in cN0 head neck cancer patients:a Meta-analysis].

    PubMed

    Li, X Y; Sun, C L; Du, X D

    2018-05-01

    Objective: The aim of this study is to evaluate the accuracy of ¹⁸F-fluorodeoxyglucose PET/CT(¹⁸F-FDG PET/CT) for the diagnosis of cervical node metastases in cN0 head neck cancer patients. Method: An electronic database search(PubMed,EMBASE,Cochrane Library,WanFang and CNKI databases)was performed. Updated quality assessment of diagnostic accuracy studies-2(QUADAS-2) was used to assess study quality. Data analyses were performed with Meta-Disc1.4. Result: Eight studies were included in the present Meta-analysis. For patient-specific data,the pooled sensitivity,specificity,diagnostic odds ratio(DOR),positive likelihood ratio(PLR),and negative likelihood(NLR)for ¹⁸F-FDG PET/CT were 0.61(95% CI 0.52-0.69),0.74(95% CI 0.68-0.78),9.62(95% CI 2.49-37.22),3.22(95% CI 1.55-6.71),and 0.42(95% CI 0.24-0.37),respectively. The area under the curve(AUC)was 0.804 1.The evaluation of heterogeneity,calculated the pooled diagnostic odds ratio,gave a Q value of 21.26( P <0.05)and an I²of 81.2%. Conclusion: The results of meta-analysis suggested that ¹⁸F-FDG PET/CT did not provide better diagnostic accuracy than CT/MRI in detecting cervical node metastases in cN0 head and neck cancer. Considering the high heterogeneity of the included studies,potential value of PET/CT needs to be validated in future studies. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  5. Accuracy of imaging methods for detection of bone tissue invasion in patients with oral squamous cell carcinoma

    PubMed Central

    Uribe, S; Rojas, LA; Rosas, CF

    2013-01-01

    The objective of this review is to evaluate the diagnostic accuracy of imaging methods for detection of mandibular bone tissue invasion by squamous cell carcinoma (SCC). A systematic review was carried out of studies in MEDLINE, SciELO and ScienceDirect, published between 1960 and 2012, in English, Spanish or German, which compared detection of mandibular bone tissue invasion via different imaging tests against a histopathology reference standard. Sensitivity and specificity data were extracted from each study. The outcome measure was diagnostic accuracy. We found 338 articles, of which 5 fulfilled the inclusion criteria. Tests included were: CT (four articles), MRI (four articles), panoramic radiography (one article), positron emission tomography (PET)/CT (one article) and cone beam CT (CBCT) (one article). The quality of articles was low to moderate and the evidence showed that all tests have a high diagnostic accuracy for detection of mandibular bone tissue invasion by SCC, with sensitivity values of 94% (MRI), 91% (CBCT), 83% (CT) and 55% (panoramic radiography), and specificity values of 100% (CT, MRI, CBCT), 97% (PET/CT) and 91.7% (panoramic radiography). Available evidence is scarce and of only low to moderate quality. However, it is consistently shown that current imaging methods give a moderate to high diagnostic accuracy for the detection of mandibular bone tissue invasion by SCC. Recommendations are given for improving the quality of future reports, in particular provision of a detailed description of the patients' conditions, the imaging instrument and both imaging and histopathological invasion criteria. PMID:23420854

  6. Incremental value of 99mTc-HYNIC-TOC SPECT/CT over whole-body planar scintigraphy and SPECT in patients with neuroendocrine tumours.

    PubMed

    Trogrlic, Mate; Težak, Stanko

    2017-06-12

    The aim of this study was to evaluate the additional value of 99m Tc-HYNIC-TOC SPECT/CT over planar whole-body (WB) scintigraphy and SPECT alone in the detection and accurate localisation of neuroendocrine tumour (NET) lesions. This study included 65 patients with a definitive histological diagnosis of NET prior to scintigraphy. Planar WB scintigraphy, SPECT, and SPECT/CT images were acquired at 4 h post-administration of 670 MBq 99m Tc-HYNIC-TOC. Additional SPECT images at 10 min after tracer administration were also acquired. Clinical and imaging follow-up findings were considered as the reference standards (minimum follow-up period, 15 months). Patient and lesion-based analyses of the efficacies of the imaging modalities were performed. While 38 patients exhibited metastasis of NETs, 27 presented no evidence of metastasis. Upon patient-based analysis, the sensitivity and specificity of SPECT/CT were found to be 88.9 and 79.3 %, respectively. The diagnostic accuracies of WB scintigraphy, 4h-SPECT, and SPECT/CT were 72.3, 73.8, and 84.6 %, respectively. The area under curve (AUC) value for SPECT/CT (0.84) was the highest, followed by those for 4h-SPECT (0.75) and WB scintigraphy (0.74). The accuracy and AUC values of SPECT/CT were significantly better compared to those of WB scintigraphy (p < 0.001), 10 min-SPECT (p < 0.001), and 4 h-SPECT (p = 0.001). The findings of SPECT/CT led to the change in treatment plan of 11 patients (16.9 %). The sensitivity and diagnostic accuracy of SPECT/CT in the evaluation of NET lesions outperforms planar WB imaging or SPECT alone.

  7. Evaluation of Prostate Cancer with 11C-Choline PET/CT for Treatment Planning, Response Assessment, and Prognosis.

    PubMed

    Ceci, Francesco; Castellucci, Paolo; Mapelli, Paola; Incerti, Elena; Picchio, Maria; Fanti, Stefano

    2016-10-01

    The aim of this review is to report on the value of 11 C-choline PET imaging as a diagnostic procedure for metastasis-directed therapies. Furthermore, the role of 11 C-choline PET/CT as a diagnostic tool for monitoring castration-resistant prostate cancer patients treated with systematic therapy is assessed. Finally, the role of 11 C-choline PET/CT in the prediction of survival in both castration-resistant prostate cancer patients and hormone-naïve patients is investigated. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  8. The diagnostic value of 18F-FDG-PET/CT and MRI in suspected vertebral osteomyelitis - a prospective study.

    PubMed

    Kouijzer, Ilse J E; Scheper, Henk; de Rooy, Jacky W J; Bloem, Johan L; Janssen, Marcel J R; van den Hoven, Leon; Hosman, Allard J F; Visser, Leo G; Oyen, Wim J G; Bleeker-Rovers, Chantal P; de Geus-Oei, Lioe-Fee

    2018-05-01

    The aim of this study was to determine the diagnostic value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET/CT) and magnetic resonance imaging (MRI) in diagnosing vertebral osteomyelitis. From November 2015 until December 2016, 32 patients with suspected vertebral osteomyelitis were prospectively included. All patients underwent both 18 F-FDG-PET/CT and MRI within 48 h. All images were independently reevaluated by two radiologists and two nuclear medicine physicians who were blinded to each others' image interpretation. 18 F-FDG-PET/CT and MRI were compared to the clinical diagnosis according to international guidelines. For 18 F-FDG-PET/CT, sensitivity, specificity, PPV, and NPV in diagnosing vertebral osteomyelitis were 100%, 83.3%, 90.9%, and 100%, respectively. For MRI, sensitivity, specificity, PPV, and NPV were 100%, 91.7%, 95.2%, and 100%, respectively. MRI detected more epidural/spinal abscesses. An important advantage of 18 F-FDG-PET/CT is the detection of metastatic infection (16 patients, 50.0%). 18 F-FDG-PET/CT and MRI are both necessary techniques in diagnosing vertebral osteomyelitis. An important advantage of 18 F-FDG-PET/CT is the visualization of metastatic infection, especially in patients with bacteremia. MRI is more sensitive in detection of small epidural abscesses.

  9. Determination of dosimetric quantities in pediatric abdominal computed tomography scans*

    PubMed Central

    Jornada, Tiago da Silva; da Silva, Teógenes Augusto

    2014-01-01

    Objective Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. PMID:25741103

  10. Unipedal Diagnostic Lymphangiography Followed by Sequential CT Examinations in Patients With Idiopathic Chyluria: A Retrospective Study.

    PubMed

    Dong, Jian; Xin, Jianfeng; Shen, Wenbin; Chen, Xiaobai; Wen, Tingguo; Zhang, Chunyan; Wang, Rengui

    2018-04-01

    The objective of our study was to investigate the clinical value of diagnostic lymphangiography followed by sequential CT examinations in patients with idiopathic chyluria. Thirty-six patients with idiopathic chyluria underwent unipedal diagnostic lymphangiography and then underwent sequential CT examinations. The examinations were reviewed separately by two radiologists. Abnormal distribution of contrast medium, lymphourinary leakages, and retrograde flow were noted, and the range and distribution of lymphatic vessel lesions were recorded. The stage of idiopathic chyluria based on CT findings and the stage based on clinical findings were compared. Therapeutic management and follow-up were recorded. Statistical analyses were performed. Compared with CT studies performed after lymphangiography, diagnostic lymphangiography showed a unique capability to depict lymphourinary leakages in three patients. Lymphourinary fistulas and abnormal dilated lymphatic vessels were found in and around kidney in all patients. CT depicted retrograde flow of lymph fluid in 47.2% of patients. The consistency in staging chyluria based on CT findings and clinical findings was fair (κ = 0.455). Twenty-nine patients underwent conservative therapy, and seven underwent surgery. Surgical therapy was superior to conservative management (no recurrence, 85.7% of patients who underwent surgery vs 62.1% of patients who underwent conservative therapy; p = 0.025). From assessing the drainage of contrast medium on unipedal diagnostic lymphangiography and the redistribution of contrast medium on sequential CT examinations, it is possible to detect the existence of lymphourinary fistulas, the precise location of lymphatic anomalies, the distribution of collateral lymphatic vessels, and hydrodynamic pressure abnormality in the lymph circulation in patients with idiopathic chyluria. CT staging of chyluria provides additional information that can be used to guide therapeutic management.

  11. Diagnostic value of CT-localizer and axial low-dose computed tomography for the detection of drug body packing.

    PubMed

    Aissa, Joel; Kohlmeier, Antonia; Rubbert, Christian; Hohn, Ulrich; Blondin, Dirk; Schleich, Christoph; Kröpil, Patric; Boos, Johannes; Antoch, Gerald; Miese, Falk

    2016-01-01

    The purpose of this study was to assess the diagnostic performance of CT-localizers in the detection of intracorporal containers. This study was approved by the research ethics committee of our clinic. From March 2012 to March 2013, 108 subjects were referred to our institute with suspected body packing. The CT-localizer and the axial CT-images were compared by two blinded observers retrospectively. Presence of body packs was assessed in consensus. Sensitivity and specificity, PPV and NPV of the CT-localizer were calculated. Packets were detected in the CT-localizer of 19 suspects. In 28 of 108 cases packs were detected in axial CT-images. Sensitivity of CT-localizer for detection of packs was 0.68, and specificity was 1.00. There were no cases rated as false positive. The PPV was 1.0 and the NPV was 0.89. The omission of the axial CT-images would have led to a mean radiation dose reduction of 1.94 ± 0.5 mSv. The value of CT-localizers lies in their high PPV. Localizers are limited by low sensitivity, compared to axial CT-images in screening of potential body packers. However, in positive cases their high PPV may possibly allow to omit the complete axial abdominal CT to achieve even lower radiation exposure. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  12. Can CT imaging features of ground-glass opacity predict invasiveness? A meta-analysis.

    PubMed

    Dai, Jian; Yu, Guoyou; Yu, Jianqiang

    2018-04-01

    A meta-analysis was conducted to investigate the diagnostic performance of computed tomography (CT) imaging features of ground-glass opacity (GGO) to predict invasiveness. Two reviewers independently searched PubMed, Medline, Web of Science, Cochrane Embase and CNKI for relevant studies. CT imaging signs of bubble lucency, speculation, lobulated margin, and pleural indentation were used as diagnostic references to discriminate pre-invasive and invasive disease. The sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the area under the SROC curve (AUC) were calculated to evaluate diagnostic efficiency. Twelve studies were finally included. Diagnostic performance ranged from 0.41 to 0.52 for sensitivity and 0.56 to 0.63 for specificity. The diagnostic positive and negative likelihood ratios ranged from 1.03 to 2.13 and 0.52 to 1.05, respectively. The DORs of the GGO CT features for discriminating invasive disease ranged from 1.02 to 4.00. The area under the ROC curve was also low, with a range of 0.60 to 0.67 for discriminating pre-invasive and invasive disease. The diagnostic value of a single CT imaging sign of GGO, such as bubble lucency, speculation, lobulated margin, or pleural indentation is limited for discriminating pre-invasive and invasive disease because of low sensitivity, specificity, and AUC. © 2018 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  13. Cervical lymph node metastases of squamous cell carcinoma of unknown origin: the diagnostic value of FDG PET/CT and clinical outcome.

    PubMed

    Dale, Einar; Moan, Jon M; Osnes, Terje A; Bogsrud, Trond V

    2017-02-01

    FDG PET/CT is perceived as a valuable diagnostic tool in addition to the standard diagnostic workup for patients with isolated neck lymph nodes of squamous cell carcinoma of unknown primary (SCCUP). For patients with SCCUP intended for primary radiotherapy, we hypothesize that the previously reported FDG PET/CT detection rates are too high. From 2008 to 2015, 30 SCCUP patients were examined with FDG PET/CT. The objective of the FDG PET/CT examination was twofold: (1) improve the radiotherapy target definition, and (2) identify the primary cancer. Before the FDG PET/CT, the patients had been through a standard workup consisting of CT of the neck and chest, examination with flexible endoscopy with patient awake, panendoscopy and examination under general anesthesia, tonsillectomy and sometimes blind sampling biopsies, and MRI (floor of the mouth). All FDG PET/CTs were performed applying a flat table, head support and fixation mask as part of the radiotherapy treatment planning. Diagnostic CT with contrast was an integrated part of the PET/CT examination. Only 1/30 patients (cancer of the vallecula) had their primary cancer detected by FDG PET/CT. In addition, a non-biopsied patient with high uptake in the ipsilateral palatine tonsil was included, giving a detection rate of ≤7 % (95 % CI 2-21 %). In this retrospective study, we found that the FDG PET/CT detection rate of the primary for SCCUP patients is lower than previously reported. It is questionable whether FDG PET/CT is necessary for these patients when improved, advanced workup is available.

  14. Differentiation between Malignant and Benign Solitary Lesions in the Liver with 18FDG PET/CT: Accuracy of Age-related Diagnostic Standard

    PubMed Central

    Xia, Qian; Feng, Yuanbo; Wu, Cheng; Huang, Gang; Liu, Jianjun; Chen, Tao; Sun, Xiaoguang; Song, Shaoli; Tong, Linjun; Ni, Yicheng

    2015-01-01

    Objective: This study was to determine the reliability of age-stratified diagnostic index in differential diagnosis of malignant and benign solitary lesions in the liver using fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (18FDG PET/CT). Methods: The enrolled 272 patients with solitary lesions in the liver were divided into three age groups, younger group (under 50 years), middle-aged group (50-69 years), and elderly group (70 years and above). Patients' ages were compared, and the optimal cut-offs of the standard uptake value (SUV) ratio (tumor-to-non-tumor ratio of the SUV), as well as areas under the curves (AUC), were evaluated in terms of malignant and benign lesions in each age group by using receiver operating characteristic (ROC) analysis. Based on optimal cut-offs, the sensitivity, specificity, accuracy were calculated, and the diagnostic accordance rate was compared between each age group and all patients, supported by 18FDG PET/CT imaging data. Results: There was a significant age difference between the malignant and benign groups (t=3.905 p=0.0001). ROC analysis showed that the optimal cut-off value in all patients, younger group, middle-aged group and elderly group was 1.25, 1.17, 1.45 and 1.25 for SUVratio, and 0.856, 0.962, 0.650, 0.973 for AUC. The chi-square test proved that diagnostic accordance rate of 18FDG PET/CT in younger group and elderly group were superior to that in all patients (χ2=13.352, P=0.0003) and (χ2=8.494, P=0.0036). Conversely, overall diagnostic accordance rate in all patient group was higher than that in middle-aged group (χ2=9.057, P=0.0026). Representative 18FDG PET/CT imaging findings are demonstrated. Conclusion: This study indicates that diagnostic optimal cut-offs of SUVratio of liver solitary lesions of 18FDG PET/CT were different in each age group. In addition, the diagnostic performance of SUVratio was better in younger and elderly groups than that in all patients, and was poorer in middle-aged group than that in all patients. Therefore, age difference appears to be one of the important factors for discriminating malignant liver lesions from benign ones using 18 FDG PET/CT. PMID:25553087

  15. A Simple Method for Differentiating Complicated Parapneumonic Effusion/Empyema from Parapneumonic Effusion Using the Split Pleura Sign and the Amount of Pleural Effusion on Thoracic CT.

    PubMed

    Tsujimoto, Naoki; Saraya, Takeshi; Light, Richard W; Tsukahara, Yayoi; Koide, Takashi; Kurai, Daisuke; Ishii, Haruyuki; Kimura, Hirokazu; Goto, Hajime; Takizawa, Hajime

    2015-01-01

    Pleural separation, the "split pleura" sign, has been reported in patients with empyema. However, the diagnostic yield of the split pleura sign for complicated parapneumonic effusion (CPPE)/empyema and its utility for differentiating CPPE/empyema from parapneumonic effusion (PPE) remains unclear. This differentiation is important because CPPE/empyema patients need thoracic drainage. In this regard, the aim of this study was to develop a simple method to distinguish CPPE/empyema from PPE using computed tomography (CT) focusing on the split pleura sign, fluid attenuation values (HU: Hounsfield units), and amount of fluid collection measured on thoracic CT prior to diagnostic thoracentesis. A total of 83 consecutive patients who underwent chest CT and were diagnosed with CPPE (n=18)/empyema (n=18) or PPE (n=47) based on the diagnostic thoracentesis were retrospectively analyzed. On univariate analysis, the split pleura sign (odds ratio (OR), 12.1; p<0.001), total amount of pleural effusion (≥30 mm) (OR, 6.13; p<0.001), HU value≥10 (OR, 5.94; p=0.001), and the presence of septum (OR, 6.43; p=0.018), atelectasis (OR, 6.83; p=0.002), or air (OR, 9.90; p=0.002) in pleural fluid were significantly higher in the CPPE/empyema group than in the PPE group. On multivariate analysis, only the split pleura sign (hazard ratio (HR), 6.70; 95% confidence interval (CI), 1.91-23.5; p=0.003) and total amount of pleural effusion (≥30 mm) on thoracic CT (HR, 7.48; 95%CI, 1.76-31.8; p=0.006) were risk factors for empyema. Sensitivity, specificity, positive predictive value, and negative predictive value of the presence of both split pleura sign and total amount of pleural effusion (≥30 mm) on thoracic CT for CPPE/empyema were 79.4%, 80.9%, 75%, and 84.4%, respectively, with an area under the curve of 0.801 on receiver operating characteristic curve analysis. This study showed a high diagnostic yield of the split pleura sign and total amount of pleural fluid (≥30 mm) on thoracic CT that is useful and simple for discriminating between CPPE/empyema and PPE prior to diagnostic thoracentesis.

  16. A Simple Method for Differentiating Complicated Parapneumonic Effusion/Empyema from Parapneumonic Effusion Using the Split Pleura Sign and the Amount of Pleural Effusion on Thoracic CT

    PubMed Central

    Tsujimoto, Naoki; Saraya, Takeshi; Light, Richard W.; Tsukahara, Yayoi; Koide, Takashi; Kurai, Daisuke; Ishii, Haruyuki; Kimura, Hirokazu; Goto, Hajime; Takizawa, Hajime

    2015-01-01

    Background Pleural separation, the “split pleura” sign, has been reported in patients with empyema. However, the diagnostic yield of the split pleura sign for complicated parapneumonic effusion (CPPE)/empyema and its utility for differentiating CPPE/empyema from parapneumonic effusion (PPE) remains unclear. This differentiation is important because CPPE/empyema patients need thoracic drainage. In this regard, the aim of this study was to develop a simple method to distinguish CPPE/empyema from PPE using computed tomography (CT) focusing on the split pleura sign, fluid attenuation values (HU: Hounsfield units), and amount of fluid collection measured on thoracic CT prior to diagnostic thoracentesis. Methods A total of 83 consecutive patients who underwent chest CT and were diagnosed with CPPE (n=18)/empyema (n=18) or PPE (n=47) based on the diagnostic thoracentesis were retrospectively analyzed. Results On univariate analysis, the split pleura sign (odds ratio (OR), 12.1; p<0.001), total amount of pleural effusion (≥30 mm) (OR, 6.13; p<0.001), HU value≥10 (OR, 5.94; p=0.001), and the presence of septum (OR, 6.43; p=0.018), atelectasis (OR, 6.83; p=0.002), or air (OR, 9.90; p=0.002) in pleural fluid were significantly higher in the CPPE/empyema group than in the PPE group. On multivariate analysis, only the split pleura sign (hazard ratio (HR), 6.70; 95% confidence interval (CI), 1.91-23.5; p=0.003) and total amount of pleural effusion (≥30 mm) on thoracic CT (HR, 7.48; 95%CI, 1.76-31.8; p=0.006) were risk factors for empyema. Sensitivity, specificity, positive predictive value, and negative predictive value of the presence of both split pleura sign and total amount of pleural effusion (≥30 mm) on thoracic CT for CPPE/empyema were 79.4%, 80.9%, 75%, and 84.4%, respectively, with an area under the curve of 0.801 on receiver operating characteristic curve analysis. Conclusion This study showed a high diagnostic yield of the split pleura sign and total amount of pleural fluid (≥30 mm) on thoracic CT that is useful and simple for discriminating between CPPE/empyema and PPE prior to diagnostic thoracentesis. PMID:26076488

  17. Comparative diagnostic value of 18F-fluoride PET-CT versus MRI for skull-base bone invasion in nasopharyngeal carcinoma.

    PubMed

    Le, Yali; Chen, Yu; Zhou, Fan; Liu, Guangfu; Huang, Zhanwen; Chen, Yue

    2016-10-01

    This study compared the diagnostic value of F-fluoride PET-computed tomography (PET-CT) and MRI in skull-base bone erosion in nasopharyngeal carcinoma (NPC) patients. A total of 93 patients with biopsy-confirmed NPC were enrolled, including 68 men and 25 women between 23 and 74 years of age. All patients were evaluated by both F-fluoride PET-CT and MRI, and the interval between the two imaging examinations was less than 20 days. The patients received no treatment either before or between scans. The studies were interpreted by two nuclear medicine physicians or two radiologists with more than 10 years of professional experience who were blinded to both the diagnosis and the results of the other imaging studies. The reference standard was skull-base bone erosion at a 20-week follow-up imaging study. On the basis of the results of the follow-up imaging studies, 52 patients showed skull-base bone erosion. The numbers of true positives, false positives, true negatives, and false negatives with F-fluoride PET-CT were 49, 4, 37, and 3, respectively. The numbers of true positives, false positives, true negatives, and false negatives with MRI were 46, 5, 36, and 6, respectively. The sensitivity, specificity, and crude accuracy of F-fluoride PET-CT were 94.23, 90.24, and 92.47%, respectively; for MRI, these values were 88.46, 87.80, and 88.17%. Of the 52 patients, 43 showed positive findings both on F-fluoride PET-CT and on MRI. Within the patient cohort, F-fluoride PET-CT and MRI detected 178 and 135 bone lesions, respectively. Both F-fluoride PET-CT and MRI have high sensitivity, specificity, and crude accuracy for detecting skull-base bone invasion in patients with NPC. F-fluoride PET-CT detected more lesions than did MRI in the skull-base bone. This suggests that F-fluoride PET-CT has a certain advantage in evaluating the skull-base bone of NPC patients. Combining the two methods could improve the diagnostic accuracy of skull-base bone invasion for NPC.

  18. [Diagnostic approach to the mild head trauma of the adult in Emergency Medicine: between biomarkers and imaging].

    PubMed

    Lippi, Giuseppe; Cervellin, Gianfranco

    2013-03-01

    Head trauma is one of the most frequent disabling diseases, with annual incidence of approximately 250-600 patients per 100,000, and mortality of 17 cases per 100,000. The mild head injury is nearly 15 times more frequent than the moderate, and more than 20 times than the severe. Although there are still contradictions regarding the clinical significance of the term "head injury", it can not be considered synonymous with traumatic brain injury. The main challenge in the diagnosis lies in the fact that severe intracranial lesions are often associated with mild head injury, especially in the presence of specific risk factors. Despite the diagnostic gold standard is represented by computed tomography (CT), its systematic performance in all patients is unadvisable for limited prevalence of positivity, radiological risk, high cost and complexity. Several potential biomarkers have been proposed for the screening of patients, but protein S100B seems now the most promising for some clinical and analytical considerations. After performing a meta-analysis of clinical trials in patients with mild head injury, we calculated a cumulative area under the curve of 0.753 (95% CI, 0.752-0.754), a negative predictive value of 97.7% (95% CI, 97.5-97.8 %) and positive predictive value of 23.6% (95% CI, 23.2-24.0%) for brain injury. We therefore developed a diagnostic algorithm based on the preliminary assessment of the Glasgow Coma Scale (GCS). Patients with GCS ​​<14 are subjected to CT, those with values GCS​14-15 without risk factors are discharged, whereas protein S100B is assessed stat in those with GCS ​​14-15 and the presence of risk factors. According to the value of the marker, patients with a concentration below the diagnostic cut-offs are discharged, whereas CT is performed in those with higher concentrations. By combining the percentage of positive CT scans in patients with mild head trauma and the negative predictive value of protein S100B, this protocol would safely abate unnecessary CT by 30-50% and costs by 28%.

  19. 68Ga-PSMA PET/CT in Patients with Rising Prostatic-Specific Antigen After Definitive Treatment of Prostate Cancer: Detection Efficacy and Diagnostic accuracy.

    PubMed

    Hamed, Maged Abdel Galil; Basha, Mohammad Abd Alkhalik; Ahmed, Hussien; Obaya, Ahmed Ali; Afifi, Amira Hamed Mohamed; Abdelbary, Eman H

    2018-06-20

    68 Ga-prostate-specific membrane antigen-11 ( 68 Ga-PSMA-11) is a recently developed positron emission tomography (PET) tracer that can detect prostate cancer (PC) relapses and metastases with high contrast resolution. The aim of this study was to assess the detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT image in patients with rising prostatic-specific antigen (PSA) after treatment of PC. The present prospective study included 188 patients who exhibited rising of PSA level on a routine follow-up examination after definitive treatment of PC. All patients underwent a 68 Ga-PSMA PET/CT examination. For each patient, we determined the disease stage, the Gleason score, and the maximum standardized uptake value of the local recurrence and extraprostatic metastases. The detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT were established by histopathology and clinical and imaging follow-up as the reference standards. 68 Ga-PSMA PET/CT detected tumour relapse in 165 patients (35 patients had local recurrence, 106 patients had extraprostatic metastases, and 24 patients had combined lesions). The sensitivity, specificity, and accuracy values of 68 Ga-PSMA PET/CT examination in the detection of PC recurrence were 98.8%, 100%, and 98.8%, respectively. 68 Ga-PSMA PET/CT revealed an overall detection rate of 87.8% (165/188) in patients with rising PSA (median of 2.2 ng/mL, and range of 0.01-70 ng/mL). 68 Ga-PSMA PET/CT is a valuable tool for the detection of PC local recurrence or extraprostatic metastases following rising PSA levels after primary definitive therapy and should be incorporated during routine work-up. Copyright © 2018. Published by Elsevier Inc.

  20. Computed tomography versus water-soluble contrast swallow in the detection of intrathoracic anastomotic leak complicating esophagogastrectomy (Ivor Lewis): a prospective study in 97 patients.

    PubMed

    Strauss, Christiane; Mal, Frederic; Perniceni, Thierry; Bouzar, Nadia; Lenoir, Stephane; Gayet, Brice; Palau, Robert

    2010-04-01

    Water-soluble contrast swallow (CS) is usually performed before refeeding for anastomosis assessment after esophagectomy with intrathoracic anastomosis but the sensitivity of CS is low. Another diagnostic approach is based on analysis of computed tomography (CT) scan with oral contrast and of CT mediastinal air images. We undertook to compare them prospectively. Ninety-seven patients with an esophageal carcinoma operated by intrathoracic anastomosis were included prospectively in a study based on a CT scan at postoperative day 3 (without oral and intravenous contrast) and CT scan and CS at day 7. CT scan analysis consisted of assessing contrast and air leakage. In case of doubt, an endoscopy was done. A diagnosis of anastomotic leak was made in 13 patients (13.4%), in 2 cases before day 7 and in 3 beyond day 7. At day 3, 94 CT scans were performed, but the diagnostic value was poor. In 95 patients with both CS and CT scan at day 7, CS disclosed a leak in 5 of 11, and CT scan was abnormal in 8 of 11. Leakage of contrast and/or presence of mediastinal gas had the best negative predictive value (95.8%). Endoscopy was done in 16 patients with only mediastinal gas at day 7 CT scan. It disclosed a normal anastomosis in 11, fibrin deposits in 4, and a leak in 1. In comparison with CS only, CT at day 7 improves the sensitivity and negative predictive value for diagnosing an anastomotic leak. In case of doubt endoscopy is advisable. This approach provides an accurate assessment of the anastomosis before refeeding.

  1. A multicenter clinical trial on the diagnostic value of dual-tracer PET/CT in pulmonary lesions using 3'-deoxy-3'-18F-fluorothymidine and 18F-FDG.

    PubMed

    Tian, Jiahe; Yang, Xiaofeng; Yu, Lijuan; Chen, Ping; Xin, Jun; Ma, Liming; Feng, Huiru; Tan, Yieyin; Zhao, Zhoushe; Wu, Wenkai

    2008-02-01

    Some new radiotracers might add useful information and improve diagnostic confidence of (18)F-FDG imaging in tumors. A multicenter clinical trial was designed to investigate the diagnostic performance of dual-tracer ((18)F-FDG and 3'-deoxy-3'-(18)F-fluorothymidine [(18)F-FLT]) PET/CT in pulmonary nodules. Fifty-five patients underwent dual-tracer imaging in 6 imaging centers using the same models of equipment and standardized protocols. The images were interpreted by a collective group of readers who were unaware of the clinical data. The diagnostic performance using either tracer alone or dual-tracers together, with or without CT, was compared. The histological diagnosis or clinical findings in a 12-mo follow-up period served as the standard of truth. In 16 patients with malignant tumor, 16 with tuberculosis, and 23 with other benign lesions, the sensitivity and specificity of (18)F-FDG and (18)F-FLT were 87.5% and 58.97% and 68.75% and 76.92%, respectively. The combination of dual-tracer PET/CT improved the sensitivity and specificity up to 100% and 89.74%. The 3 subgroups of patients could be best separated when the (18)F-FLT/(18)F-FDG standardized uptake value ratio of 0.4-0.90 was used as the threshold. By reflecting different biologic features, the dual-tracer PET/CT using (18)F-FDG and (18)F-FLT favorably affected the diagnosis of lung nodules.

  2. Comparison of ultrasound versus computed tomography for the detection of kidney stones in the pediatric population: a clinical effectiveness study.

    PubMed

    Roberson, Nathaniel P; Dillman, Jonathan R; O'Hara, Sara M; DeFoor, William R; Reddy, Pramod P; Giordano, Richard M; Trout, Andrew T

    2018-07-01

    The incidence of pediatric nephrolithiasis in the United States is increasing. There is a paucity of literature comparing the diagnostic performance of computed ultrasound (US) to tomography (CT) in the pediatric population. To determine the diagnostic performance of renal US for nephrolithiasis in children using a clinical effectiveness approach. Institutional review board approval with a waiver of informed consent was obtained for this retrospective, HIPAA-complaint investigation. Billing records and imaging reports were used to identify children (≤18 years old) evaluated for nephrolithiasis by both US and unenhanced CT within 24 h between March 2012 and March 2017. Imaging reports were reviewed for presence, number, size and location of kidney stones. Diagnostic performance of US (reference standard=CT) was calculated per renal unit (left/right kidney) and per renal sector (four sectors per kidney). For sector analysis, US was considered truly positive if a stone was identified at CT in the same or an adjacent sector. There were 68 renal stones identified by CT in 30/69 patients (43%). Mean patient age was 14.7±3.6 years, and 35 were boys. For detecting nephrolithiasis in any kidney, US was 66.7% (48.8-80.8%) sensitive and 97.4% (86.8-99.9%) specific (positive predictive value=95.2% [77.3-99.8%], negative predictive value=79.2% [65.7-88.3%], positive likelihood ratio=26.0). Per renal sector, US was 59.7% (46.7-71.4%) sensitive and 97.4% (95.5-98.5%) specific (positive predictive value=72.3% [58.2-83.1%], negative predictive value=95.4% [93.2-96.9%], positive likelihood ratio=22.5). Of the 30 stones not detected by US, only 3 were >3 mm at CT. In clinical practice, US has high specificity for detecting nephrolithiasis in children but only moderate sensitivity and false negatives are common.

  3. A novel diagnostic method (spectral computed tomography of sacroiliac joints) for axial spondyloarthritis.

    PubMed

    Zhang, Ping; Yu, Kai Hu; Guo, Rui Min; Ran, Jun; Liu, Yao; Morelli, John; Runge, Val M; Li, Xiao Ming

    2016-08-01

    To evaluate the diagnostic value of spectral computed tomography (CT) of sacroiliac joints for axial spondyloarthritis (SpA). We retrospectively analyzed the records of 125 patients with low back pain (LBP) suspected of having SpA. Each patient underwent sacroiliac joint spectral CT examination. Water- and calcium-based material decomposition images were reconstructed. After 3-6 months of follow-up, 76 were diagnosed with SpA, and the remaining 49 patients were diagnosed with nonspecific LBP (nLBP). The slope of sacroiliac bone marrow HU (Hounsfield unit) curve (λHU), CT value, and bone marrow to normal muscle ratios of water and calcium concentrations in the ilium and sacrum were calculated and compared between nLBP and SpA patients. The iliac λHU was 8.26 ± 3.91 for nLBP and 9.81 ± 4.92 for SpA. The mean iliac ratios of water and calcium concentrations were 1.04 ± 0.03 and 21.67 ± 4.40, respectively, for nLBP, and 1.07 ± 0.04 and 111.5 ± 358.98, respectively, for SpA. The mean iliac CT values were 311.12 ± 86.52 HU for nLBP and 423.97 ± 127.51 HU for SpA. There were statistically significant differences in iliac ratios of water and calcium concentrations, CT value, and λHU between nLBP and SpA patients (p < 0.05). The sensitivity of iliac λHU was the highest. The diagnostic odds ratio of ratio of iliac calcium concentration was the highest, and its negative likelihood ratio was the lowest. Spectral CT not only shows bone erosion and sclerosis, but also shows and quantitatively measures bone marrow edema in the sacroiliac joints of SpA patients. Copyright © 2015. Published by Elsevier B.V.

  4. Accuracy in contouring of small and low contrast lesions: Comparison between diagnostic quality computed tomography scanner and computed tomography simulation scanner-A phantom study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Yick Wing, E-mail: mpr@hksh.com; Wong, Wing Kei Rebecca; Yu, Siu Ki

    2012-01-01

    To evaluate the accuracy in detection of small and low-contrast regions using a high-definition diagnostic computed tomography (CT) scanner compared with a radiotherapy CT simulation scanner. A custom-made phantom with cylindrical holes of diameters ranging from 2-9 mm was filled with 9 different concentrations of contrast solution. The phantom was scanned using a 16-slice multidetector CT simulation scanner (LightSpeed RT16, General Electric Healthcare, Milwaukee, WI) and a 64-slice high-definition diagnostic CT scanner (Discovery CT750 HD, General Electric Healthcare). The low-contrast regions of interest (ROIs) were delineated automatically upon their full width at half maximum of the CT number profile inmore » Hounsfield units on a treatment planning workstation. Two conformal indexes, CI{sub in}, and CI{sub out}, were calculated to represent the percentage errors of underestimation and overestimation in the automated contours compared with their actual sizes. Summarizing the conformal indexes of different sizes and contrast concentration, the means of CI{sub in} and CI{sub out} for the CT simulation scanner were 33.7% and 60.9%, respectively, and 10.5% and 41.5% were found for the diagnostic CT scanner. The mean differences between the 2 scanners' CI{sub in} and CI{sub out} were shown to be significant with p < 0.001. A descending trend of the index values was observed as the ROI size increases for both scanners, which indicates an improved accuracy when the ROI size increases, whereas no observable trend was found in the contouring accuracy with respect to the contrast levels in this study. Images acquired by the diagnostic CT scanner allow higher accuracy on size estimation compared with the CT simulation scanner in this study. We recommend using a diagnostic CT scanner to scan patients with small lesions (<1 cm in diameter) for radiotherapy treatment planning, especially for those pending for stereotactic radiosurgery in which accurate delineation of small-sized, low-contrast regions is important for dose calculation.« less

  5. PAEDIATRIC CT EXPOSURE PRACTICE IN THE COUNTY OF RIO DE JANEIRO: THE NEED TO ESTABLISH DIAGNOSTIC REFERENCE LEVELS.

    PubMed

    de Jesus, Fillipe M; Magalhães, Luis A G; Kodlulovich, Simone

    2016-11-01

    A pilot study of dose indicators in paediatric computed tomography (CT) was conducted to prove the need to establish diagnostic reference levels (DRLs) for the county of Rio de Janeiro. The dose descriptors were estimated from the beam dosimetry by applying the protocols used in each examination. The total patient sample included 279 children. Regarding the comparison of the dose-length product values among the hospitals, the high-resolution chest CT scans were distinguished among the three types of examinations, due to the discrepancies of 1148 % (1-5 y age group) and 2248 % (5-10 y age group) presented in Hospital A's dose-length product values relative to Hospital D's dose-length product values. The results showed that without DRL, the dose variation can be significant between hospitals in the same county for the same age group in the same examination. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. A prospective randomized multicentre study of the impact of gallium-68 prostate-specific membrane antigen (PSMA) PET/CT imaging for staging high-risk prostate cancer prior to curative-intent surgery or radiotherapy (proPSMA study): clinical trial protocol.

    PubMed

    Hofman, Michael S; Murphy, Declan G; Williams, Scott G; Nzenza, Tatenda; Herschtal, Alan; Lourenco, Richard De Abreu; Bailey, Dale L; Budd, Ray; Hicks, Rodney J; Francis, Roslyn J; Lawrentschuk, Nathan

    2018-05-03

    Accurate staging of patients with prostate cancer (PCa) is important for therapeutic decision-making. Relapse after surgery or radiotherapy of curative intent is not uncommon and, in part, represents a failure of staging with current diagnostic imaging techniques to detect disease spread. Prostate-specific membrane antigen (PSMA) positron-emission tomography (PET)/computed tomography (CT) is a new whole-body scanning technique that enables visualization of PCa with high contrast. The hypotheses of this study are that: (i) PSMA-PET/CT has improved diagnostic performance compared with conventional imaging; (ii) PSMA-PET/CT should be used as a first-line diagnostic test for staging; (iii) the improved diagnostic performance of PSMA-PET/CT will result in significant management impact; and (iv) there are economic benefits if PSMA-PET/CT is incorporated into the management algorithm. The proPSMA trial is a prospective, multicentre study in which patients with untreated high-risk PCa will be randomized to gallium-68-PSMA-11 PET/CT or conventional imaging, consisting of CT of the abdomen/pelvis and bone scintigraphy with single-photon emission CT/CT. Patients eligible for inclusion are those with newly diagnosed PCa with select high-risk features, defined as International Society of Urological Pathology grade group ≥3 (primary Gleason grade 4, or any Gleason grade 5), prostate-specific antigen level ≥20 ng/mL or clinical stage ≥T3. Patients with negative, equivocal or oligometastatic disease on first line-imaging will cross over to receive the other imaging arm. The primary objective is to compare the accuracy of PSMA-PET/CT with that of conventional imaging for detecting nodal or distant metastatic disease. Histopathological, imaging and clinical follow-up at 6 months will define the primary endpoint according to a predefined scoring system. Secondary objectives include comparing management impact, the number of equivocal studies, the incremental value of second-line imaging in patients who cross over, the cost of each imaging strategy, radiation exposure, inter-observer agreement and safety of PSMA-PET/CT. Longer-term follow-up will also assess the prognostic value of a negative PSMA-PET/CT. This trial will provide data to establish whether PSMA-PET/CT should replace conventional imaging in the primary staging of select high-risk localized PCa, or whether it should be used to provide incremental diagnostic information in selected cases. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  7. Multicenter evaluation of molecular and culture-dependent diagnostics for Shigella species and Entero-invasive Escherichia coli in the Netherlands.

    PubMed

    van den Beld, Maaike J C; Friedrich, Alexander W; van Zanten, Evert; Reubsaet, Frans A G; Kooistra-Smid, Mirjam A M D; Rossen, John W A

    2016-12-01

    An inter-laboratory collaborative trial for the evaluation of diagnostics for detection and identification of Shigella species and Entero-invasive Escherichia coli (EIEC) was performed. Sixteen Medical Microbiological Laboratories (MMLs) participated. MMLs were interviewed about their diagnostic methods and a sample panel, consisting of DNA-extracts and spiked stool samples with different concentrations of Shigella flexneri, was provided to each MML. The results of the trial showed an enormous variety in culture-dependent and molecular diagnostic techniques currently used among MMLs. Despite the various molecular procedures, 15 out of 16 MMLs were able to detect Shigella species or EIEC in all the samples provided, showing that the diversity of methods has no effect on the qualitative detection of Shigella flexneri. In contrast to semi quantitative analysis, the minimum and maximum values per sample differed by approximately five threshold cycles (Ct-value) between the MMLs included in the study. This indicates that defining a uniform Ct-value cut-off for notification to health authorities is not advisable. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. SU-E-P-10: Establishment of Local Diagnostic Reference Levels of Routine Exam in Computed Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yeh, M; Wang, Y; Weng, H

    Introduction National diagnostic reference levels (NDRLs) can be used as a reference dose of radiological examination can provide radiation dose as the basis of patient dose optimization. Local diagnostic reference levels (LDRLs) by periodically view and check doses, more efficiency to improve the way of examination. Therefore, the important first step is establishing a diagnostic reference level. Computed Tomography in Taiwan had been built up the radiation dose limit value,in addition, many studies report shows that CT scan contributed most of the radiation dose in different medical. Therefore, this study was mainly to let everyone understand DRL’s international status. Formore » computed tomography in our hospital to establish diagnostic reference levels. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). Each exam each different body part, we collect 10 patients at least. Carried out the routine examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. Results: The majority of patients (75%) were between 60–70 Kg of body weight. There are 25 examinations in this study. Table 1 shows the LDRL of each CT routine examination. Conclusions: Therefore, this study would like to let everyone know DRL’s international status, but also establishment of computed tomography of the local reference levels for our hospital, and providing radiation reference, as a basis for optimizing patient dose.« less

  9. Spatial resolution measurements by Radia diagnostic software with SEDENTEXCT image quality phantom in cone beam CT for dental use.

    PubMed

    Watanabe, Hiroshi; Nomura, Yoshikazu; Kuribayashi, Ami; Kurabayashi, Tohru

    2018-02-01

    We aimed to employ the Radia diagnostic software with the safety and efficacy of a new emerging dental X-ray modality (SEDENTEXCT) image quality (IQ) phantom in CT, and to evaluate its validity. The SEDENTEXCT IQ phantom and Radia diagnostic software were employed. The phantom was scanned using one medical full-body CT and two dentomaxillofacial cone beam CTs. The obtained images were imported to the Radia software, and the spatial resolution outputs were evaluated. The oversampling method was employed using our original wire phantom as a reference. The resultant modulation transfer function (MTF) curves were compared. The null hypothesis was that MTF curves generated using both methods would be in agreement. One-way analysis of variance tests were applied to the f50 and f10 values from the MTF curves. The f10 values were subjectively confirmed by observing the line pair modules. The Radia software reported the MTF curves on the xy-plane of the CT scans, but could not return f50 and f10 values on the z-axis. The null hypothesis concerning the reported MTF curves on the xy-plane was rejected. There were significant differences between the results of the Radia software and our reference method, except for f10 values in CS9300. These findings were consistent with our line pair observations. We evaluated the validity of the Radia software with the SEDENTEXCT IQ phantom. The data provided were semi-automatic, albeit with problems and statistically different from our reference. We hope the manufacturer will overcome these limitations.

  10. A Comparison between 18F-FDG PET/CT Imaging and Biological and Radiological Findings in Restaging of Hepatoblastoma Patients

    PubMed Central

    Treglia, Giorgio; Pagano, Manuela; Fania, Piercarlo; Basso, Maria Eleonora; Fagioli, Franca; Ficola, Umberto

    2013-01-01

    Background. In this study we retrospectively evaluated if 18F-FDG-PET/CT provided incremental diagnostic information over CI in a group of hepatoblastoma patients performing restaging. Procedure. Nine patients (mean age: 5.9 years; range: 3.1–12 years) surgically treated for hepatoblastoma were followed up by clinical examination, serum α-FP monitoring, and US. CI (CT or MRI) and PET/CT were performed in case of suspicion of relapse. Fine-needle aspiration biopsies (FNAB) were carried out for final confirmation if the results of CI, PET/CT, and/or α-FP levels were suggestive of relapse. PET/CT and CI findings were analyzed for comparison purposes, using FNAB as reference standard. Results. α-FP level was suggestive of disease recurrence in 8/9 patients. Biopsy was performed in 8/9 cases. CI and PET/CT resulted to be concordant in 5/9 patients (CI identified recurrence of disease, but 18F-FDG-PET/CT provided a better definition of disease extent); in 4/9 cases, CI diagnostic information resulted in negative findings, whereas PET/CT correctly detected recurrence of disease. 18F-FDG-PET/CT showed an agreement of 100% (8/8) with FNAB results. Conclusions. 18F-FDG-PET/CT scan seems to better assess HB patients with respect to CI and may provide incremental diagnostic value in the restaging of this group of patients. PMID:24063012

  11. Value of 18F-FDG PET/CT in diagnosing chronic Q fever in patients with central vascular disease.

    PubMed

    Hagenaars, J C J P; Wever, P C; Vlake, A W; Renders, N H M; van Petersen, A S; Hilbink, M; de Jager-Leclercq, M G L; Moll, F L; Koning, O H J; Hoekstra, C J

    2016-08-01

    The aim of this study is to describe the value of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (18F-FDG PET/CT) in diagnosing chronic Q fever in patients with central vascular disease and the added value of 18F-FDG PET/CT in the diagnostic combination strategy as described in the Dutch consensus guideline for diagnosing chronic Q fever. 18F-FDG PET/CT was performed in patients with an abdominal aortic aneurysm or aorto-iliac reconstruction and chronic Q fever, diagnosed by serology and positive PCR for Coxiella burnetii DNA in blood and/or tissue (PCR-positive study group). Patients with an abdominal aortic aneurysm or aorto-iliac reconstruction without clinical and serological findings indicating Q fever infection served as a control group. Patients with a serological profile of chronic Q fever and a negative PCR in blood were included in additional analyses (PCR-negative study group). Thirteen patients were evaluated in the PCR-positive study group and 22 patients in the control group. 18F-FDG PET/CT indicated vascular infection in 6/13 patients in the PCR-positive study group and 2/22 patients in the control group. 18F-FDG PET/CT demonstrated a sensitivity of 46% (95% CI: 23-71%), specificity of 91% (95% CI: 71-99%), positive predictive value of 75% (95% CI:41-93%) and negative predictive value of 74% (95% CI: 55-87%). In the PCR-negative study group, 18F-FDG PET/CT was positive in 10/20 patients (50%). The combination of 18F-FDG PET/CT, as an imaging tool for identifying a focus of infection, and Q fever serology is a valid diagnostic strategy for diagnosing chronic Q fever in patients with central vascular disease.

  12. Is there any significance of lung cancer histology to compare the diagnostic accuracies of (18)F-FDG-PET/CT and (99m)Tc-MDP BS for the detection of bone metastases in advanced NSCLC?

    PubMed

    Inal, Ali; Kaplan, Muhammed Ali; Kucukoner, Mehmet; Urakcı, Zuhat; Dostbil, Zeki; Komek, Hail; Onder, Hakan; Tasdemir, Bekir; Isıkdogan, Abdurrahman

    2014-01-01

    Bone scintigraphy (BS) and fluorine-18 deoxyglucose positron emission tomography computed tomography ((18)F-FDG-PET/CT) are widely used for the detection of bone involvement. The optimal imaging modality for the detection of bone metastases in histological subgroups of non-small cell lung cancer (NSCLC) remains ambiguous. The aim of this study was to compare the efficacy of (18)F-FDG-PET/C and 99mTc-methylene diphosphonate ((99m)Tc-MDP) BS in the detection of bone metastases of patients in NSCLC. Specifically, we compared the diagnostic accuracies of these imaging techniques evaluating bone metastasis in histological subgroups of NSCLC. Fifty-three patients with advanced NSCLC, who had undergone both (18)F-FDG-PET/CT and BS and were eventually diagnosed as having bone metastasis, were enrolled in this retrospective study. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of (18)F-FDG-PET/CT and BS were 90.4%, 99.4%, 98.1%, 96.6%, 97.0% and 84.6%, 93.1%, 82.5%, 93.2, 90.8%, respectively. The κ statistics were calculated for (18)F-FDG-PET/CT and BS. The κ-value was 0.67 between (18)F-FDG-PET/CT and BS in all patients. On the other hand, the κ-value was 0.65 in adenocarcinoma, and 0.61 in squamous cell carcinoma between (18)F-FDG-PET/CT and BS. The κ-values suggested excellent agreement between all patients and histological subgroups of NSCLC. (18)F-FDG-PET/CT was more favorable than BS in the screening of metastatic bone lesions, but the trend did not reach statistical significance in all patients and histological subgroups of NSCLC. Our results need to be validated in prospective and larger study clinical trials to further clarify this topic.

  13. Value of planar lymphoscintigraphy versus SPECT/CT in evaluation of sentinel lymph node in trunk melanoma - one center, large series, retrospective study.

    PubMed

    Benke, Małgorzata; Wocial, Krzysztof; Lewandowska, Weronika; Rutkowski, Piotr Łukasz; Teterycz, Paweł; Jarek, Piotr; Dedecjus, Marek

    2018-06-29

    Background Localization and histopathological examination of sentinel lymph node (SLN) is a standard of melanoma treatment. The first stage of identification of the SLN is the preoperative lymphoscintigraphy. The aim of this study was to assess and compare diagnostic value of planar lymphoscintigraphy (PL) and SPECT/CT in sentinel lymph node biopsy (SLNB) procedure performed in patients with cutaneous trunk melanoma. Material and Methods Between 2015 and 2016, patients with trunk melanoma (N=255, F/M 95/160), aged from 17 to 88 after an excisional biopsy, with primary tumor ≥ pT1b (AJCC 2009, median Breslow thickness 2.0± 3.13) were included in the study. In all the patients PL was followed by SPECT/CT 1-3 h after injection of 99mTc- colloid particles, and SLNB was performed the next day. Results SPECT-CT revealed 78 (18.6%) SLN more than PL, and in 40 patients showed additional lymph drainage regions leading to surgical adjustments. In 18 patients (7.1%) SPECT-CT revealed SLN not visible in the PL (false-negative PL) and in 22 patients (8.6%), foci of uptake interpreted in PL as hot SLNs were found to be non-nodal sites of uptake when assessed on SPECT/CT (false positive PL). SPECT-CT vs. PL mismatch was observed in 31 patients (12.2%) and was the most common in patients with primary lesions located in the anterior inferior medial region (75%). Conclusions Results of the presented study indicates the high diagnostic value of SPECT-CT in assessment of SLNs and proved that SPECT-CT increases the sensitivity and accuracy of SLN identification as compared to PL even in very experienced hands.

  14. Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality.

    PubMed

    Ippolito, Davide; Fior, Davide; Franzesi, Cammillo Talei; Riva, Luca; Casiraghi, Alessandra; Sironi, Sandro

    2017-12-01

    Effective radiation dose in coronary CT angiography (CTCA) for coronary artery bypass graft (CABG) evaluation is remarkably high because of long scan lengths. Prospective electrocardiographic gating with iterative reconstruction can reduce effective radiation dose. To evaluate the diagnostic performance of low-kV CT angiography protocol with prospective ecg-gating technique and iterative reconstruction (IR) algorithm in follow-up of CABG patients compared with standard retrospective protocol. Seventy-four non-obese patients with known coronary disease treated with artery bypass grafting were prospectively enrolled. All the patients underwent 256 MDCT (Brilliance iCT, Philips) CTCA using low-dose protocol (100 kV; 800 mAs; rotation time: 0.275 s) combined with prospective ECG-triggering acquisition and fourth-generation IR technique (iDose 4 ; Philips); all the lengths of the bypass graft were included in the evaluation. A control group of 42 similar patients was evaluated with a standard retrospective ECG-gated CTCA (100 kV; 800 mAs).On both CT examinations, ROIs were placed to calculate standard deviation of pixel values and intra-vessel density. Diagnostic quality was also evaluated using a 4-point quality scale. Despite the statistically significant reduction of radiation dose evaluated with DLP (study group mean DLP: 274 mGy cm; control group mean DLP: 1224 mGy cm; P value < 0.001). No statistical differences were found between PGA group and RGH group regarding intra-vessel density absolute values and SNR. Qualitative analysis, evaluated by two radiologists in "double blind", did not reveal any significant difference in diagnostic quality of the two groups. The development of high-speed MDCT scans combined with modern IR allows an accurate evaluation of CABG with prospective ECG-gating protocols in a single breath hold, obtaining a significant reduction in radiation dose.

  15. Diagnostic performance of dual-energy CT stress myocardial perfusion imaging: direct comparison with cardiovascular MRI.

    PubMed

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K

    2014-12-01

    The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.

  16. Added Value of Coronal Reformations for Duty Radiologists and for Referring Physicians or Surgeons in the CT Diagnosis of Acute Appendicitis

    PubMed Central

    Lee, Kyoung Ho; Hahn, Seokyung; Lee, Kyung Won; Lee, Hak Jong; Kim, Tae Jung; Kang, Sung-Bum; Shin, Joong Ho; Park, Byung Joo

    2006-01-01

    Objective To assess the added value of coronal reformation for radiologists and for referring physicians or surgeons in the CT diagnosis of acute appendicitis. Materials and Methods Contrast-enhanced CT was performed using 16-detector-row scanners in 110 patients, 46 of whom had appendicitis. Transverse (5-mm thickness, 4-mm increment), coronal (5-mm thickness, 4-mm increment), and combined transverse and coronal sections were interpreted by four radiologists, two surgeons and two emergency physicians. The area under the receiver operating characteristic curve (Az value), sensitivity, specificity (McNemar test), diagnostic confidence and appendiceal visualization (Wilcoxon signed rank test) were compared. Results For radiologists, the additional coronal sections tended to increase the Az value (0.972 vs. 0.986, p = 0.076) and pooled sensitivity (92% [95% CI: 88, 96] vs. 96% [93, 99]), and enhanced appendiceal visualization in true-positive cases (p = 0.031). For non-radiologists, no such enhancement was observed, and the confidence for excluding acute appendicitis declined (p = 0.013). Coronal sections alone were inferior to transverse sections for diagnostic confidence as well as appendiceal visualization for each reader group studied (p < 0.05). Conclusion The added value of coronal reformation is more apparent for radiologists compared to referring physicians or surgeons in the CT diagnosis of acute appendicitis. PMID:16799269

  17. Derivation of new diagnostic reference levels for neuro-paediatric computed tomography examinations in Switzerland.

    PubMed

    Wagner, Franca; Bize, Julie; Racine, Damien; Le Coultre, Regis; Francis, Verdun; Trueb, Philipp; Treier, Reto

    2018-05-22

    Definition of new national diagnostic reference levels (DRLs) for volume computed tomography dose index (CTDIvol) and dose length product (DLP) for neuro-paediatric CT examinations depending on the medical indication. Methods: Paediatric cranial CT data sets acquired between January 2013 and December 2016 were retrospectively collected between July 2016 and March 2017 from the eight largest university and cantonal hospitals that perform most of the neuro-paediatric CTs in Switzerland. A consensus review of CTDIvol and DLP was undertaken for the three defined anatomical regions: brain, facial bone and petrous bone; each with and without contrast medium application. All indications for cranial CT imaging in paediatrics were assigned to one of these three regions. Descriptive statistical analysis of the distribution of the median values for CTDIvol and DLP yielded minimum, maximum, 25th percentile (1st quartile), median (2nd quartile) and 75th percentile (3rd quartile). New DRLs for neuro-paediatric CT examinations in Switzerland were based on the 75th percentiles of the distributions of the median values of all eight centres. Where appropriate, values were rounded such that the DRLs increase or at least remain constant as the age of the patient increases. Results: Our results revealed DRLs for CTDIvol and DLP up to 20% lower than the DRLs used so far in Switzerland and elsewhere in Europe. Conclusions: This study provides Swiss neuro-paediatric CT DRL values to establish optimum conditions for paediatric cranial CT examinations. Periodic national updates of DRLs, following international comparisons, are essential. . Creative Commons Attribution license.

  18. A study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure.

    PubMed

    Lützen, Ulf; Naumann, Carsten Maik; Marx, Marlies; Zhao, Yi; Jüptner, Michael; Baumann, René; Papp, László; Zsótér, Norbert; Aksenov, Alexey; Jünemann, Klaus-Peter; Zuhayra, Maaz

    2016-09-07

    Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.

  19. Adaptive statistical iterative reconstruction use for radiation dose reduction in pediatric lower-extremity CT: impact on diagnostic image quality.

    PubMed

    Shah, Amisha; Rees, Mitchell; Kar, Erica; Bolton, Kimberly; Lee, Vincent; Panigrahy, Ashok

    2018-06-01

    For the past several years, increased levels of imaging radiation and cumulative radiation to children has been a significant concern. Although several measures have been taken to reduce radiation dose during computed tomography (CT) scan, the newer dose reduction software adaptive statistical iterative reconstruction (ASIR) has been an effective technique in reducing radiation dose. To our knowledge, no studies are published that assess the effect of ASIR on extremity CT scans in children. To compare radiation dose, image noise, and subjective image quality in pediatric lower extremity CT scans acquired with and without ASIR. The study group consisted of 53 patients imaged on a CT scanner equipped with ASIR software. The control group consisted of 37 patients whose CT images were acquired without ASIR. Image noise, Computed Tomography Dose Index (CTDI) and dose length product (DLP) were measured. Two pediatric radiologists rated the studies in subjective categories: image sharpness, noise, diagnostic acceptability, and artifacts. The CTDI (p value = 0.0184) and DLP (p value <0.0002) were significantly decreased with the use of ASIR compared with non-ASIR studies. However, the subjective ratings for sharpness (p < 0.0001) and diagnostic acceptability of the ASIR images (p < 0.0128) were decreased compared with standard, non-ASIR CT studies. Adaptive statistical iterative reconstruction reduces radiation dose for lower extremity CTs in children, but at the expense of diagnostic imaging quality. Further studies are warranted to determine the specific utility of ASIR for pediatric musculoskeletal CT imaging.

  20. Diagnostic reference levels of paediatric computed tomography examinations performed at a dedicated Australian paediatric hospital.

    PubMed

    Bibbo, Giovanni; Brown, Scott; Linke, Rebecca

    2016-08-01

    Diagnostic Reference Levels (DRL) of procedures involving ionizing radiation are important tools to optimizing radiation doses delivered to patients and in identifying cases where the levels of doses are unusually high. This is particularly important for paediatric patients undergoing computed tomography (CT) examinations as these examinations are associated with relatively high-dose. Paediatric CT studies, performed at our institution from January 2010 to March 2014, have been retrospectively analysed to determine the 75th and 95th percentiles of both the volume computed tomography dose index (CTDIvol ) and dose-length product (DLP) for the most commonly performed studies to: establish local diagnostic reference levels for paediatric computed tomography examinations performed at our institution, benchmark our DRL with national and international published paediatric values, and determine the compliance of CT radiographer with established protocols. The derived local 75th percentile DRL have been found to be acceptable when compared with those published by the Australian National Radiation Dose Register and two national children's hospitals, and at the international level with the National Reference Doses for the UK. The 95th percentiles of CTDIvol for the various CT examinations have been found to be acceptable values for the CT scanner Dose-Check Notification. Benchmarking CT radiographers shows that they follow the set protocols for the various examinations without significant variations in the machine setting factors. The derivation of DRL has given us the tool to evaluate and improve the performance of our CT service by improved compliance and a reduction in radiation dose to our paediatric patients. We have also been able to benchmark our performance with similar national and international institutions. © 2016 The Royal Australian and New Zealand College of Radiologists.

  1. Analysis of pulmonary pure ground-glass nodule in enhanced dual energy CT imaging for predicting invasive adenocarcinoma: comparing with conventional thin-section CT imaging

    PubMed Central

    Zhang, Ying; Tang, Jian; Xu, Jianrong

    2017-01-01

    Background To investigate the value of dual energy computed tomography (DECT) parameters (including iodine concentration and monochromatic CT numbers) for predicting pure ground-glass nodules (pGGNs) of invasive adenocarcinoma (IA). Methods A total of 55 resected pGGNs evaluated with both unenhanced thin-section CT (TSCT) and enhanced DECT scans were included. Correlations between histopathology [adenocarcinoma in situ (AIS), minimally IA (MIA), and IA] and CT scan characteristics were examined. CT scan and clinicodemographic data were investigated by univariate and multivariate analysis to identify features that helped distinguish IA from AIS or MIA. Results Both normalized iodine concentration (NIC) of IA and slope of spectral curve [slope(k)] were not significantly different between IA and AIS or MIA. Size, performance of pleural retraction and enhanced monochromatic CT attenuation values of 120–140 keV were significantly higher for IA. In multivariate regression analysis, size and enhanced monochromatic CT number of 140 keV were independent predictors for IA. Using the two parameters together, the diagnostic capacity of IA could be improved from 0.697 or 0.635 to 0.713. Conclusions DECT could help demonstrate blood supply and indicate invasion extent of pGGNs, and monochromatic CT number of higher energy (especially 140 keV) would be better for diagnosing IA than lower energies. Together with size of pGGNs, the diagnostic capacity of IA could be better. PMID:29312701

  2. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma.

    PubMed

    Qi, Zhihua; Gates, Erica L; O'Brien, Maureen M; Trout, Andrew T

    2018-02-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations.

  3. Latest generation of flat detector CT as a peri-interventional diagnostic tool: a comparative study with multidetector CT.

    PubMed

    Leyhe, Johanna Rosemarie; Tsogkas, Ioannis; Hesse, Amélie Carolina; Behme, Daniel; Schregel, Katharina; Papageorgiou, Ismini; Liman, Jan; Knauth, Michael; Psychogios, Marios-Nikos

    2017-12-01

    Flat detector CT (FDCT) has been used as a peri-interventional diagnostic tool in numerous studies with mixed results regarding image quality and detection of intracranial lesions. We compared the diagnostic aspects of the latest generation FDCT with standard multidetector CT (MDCT). 102 patients were included in our retrospective study. All patients had undergone interventional procedures. FDCT was acquired peri-interventionally and compared with postinterventional MDCT regarding depiction of ventricular/subarachnoidal spaces, detection of intracranial hemorrhage, and delineation of ischemic lesions using an ordinal scale. Ischemic lesions were quantified with the Alberta Stroke Program Early CT Scale (ASPECTS) on both examinations. Two neuroradiologists with varying grades of experience and a medical student scored the anonymized images separately, blinded to the clinical history. The two methods were of equal diagnostic value regarding evaluation of the ventricular system and the subarachnoidal spaces. Subarachnoidal, intraventricular, and parenchymal hemorrhages were detected with a sensitivity of 95%, 97%, and 100% and specificity of 97%, 100%, and 99%, respectively, using FDCT. Gray-white differentiation was feasible in the majority of FDCT scans, and ischemic lesions were detected with a sensitivity of 71% on FDCT, compared with MDCT scans. The mean difference in ASPECTS values on FDCT and MDCT was 0.5 points (95% CI 0.12 to 0.88). The latest generation of FDCT is a reliable and accurate tool for the detection of intracranial hemorrhage. Gray-white differentiation is feasible in the supratentorial region. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Diagnosing Early Ischemic Changes with the Latest-Generation Flat Detector CT: A Comparative Study with Multidetector CT.

    PubMed

    Maier, I L; Leyhe, J R; Tsogkas, I; Behme, D; Schregel, K; Knauth, M; Schnieder, M; Liman, J; Psychogios, M-N

    2018-05-01

    One-stop management of mechanical thrombectomy-eligible patients with large-vessel occlusion represents an innovative approach in acute stroke treatment. This approach reduces door-to-reperfusion times by omitting multidetector CT, using flat detector CT as pre-mechanical thrombectomy imaging. The purpose of this study was to compare the diagnostic performance of the latest-generation flat detector CT with multidetector CT. Prospectively derived data from patients with ischemic stroke with large-vessel occlusion and mechanical thrombectomy were analyzed in this monocentric study. All included patients underwent multidetector CT before referral to our comprehensive stroke center and flat detector CT in the angiography suite before mechanical thrombectomy. Diagnosis of early ischemic signs, quantified by the ASPECTS, was compared between modalities using cross tables, the Pearson correlation, and Bland-Altman plots. The predictive value of multidetector CT- and flat detector CT-derived ASPECTS for functional outcome was investigated using area under the receiver operating characteristic curve analysis. Of 25 patients, 24 (96%) had flat detector CT with sufficient diagnostic quality. Median multidetector CT and flat detector CT ASPECTSs were 7 (interquartile range, 5.5-9 and 4.25-8, respectively) with a mean period of 143.6 ± 49.5 minutes between both modalities. The overall sensitivity was 85.1% and specificity was 83.1% for flat detector CT ASPECTS compared with multidetector CT ASPECTS as the reference technique. Multidetector CT and flat detector CT ASPECTS were strongly correlated ( r = 0.849, P < .001) and moderately predicted functional outcome (area under the receiver operating characteristic curve, 0.738; P = .007 and .715; P = .069, respectively). Determination of ASPECTS on flat detector CT is feasible, showing no significant difference compared with multidetector CT ASPECTS and a similar predictive value for functional outcome. Our findings support the use of flat detector CT for emergency stroke imaging before mechanical thrombectomy to reduce door-to-groin time. © 2018 by American Journal of Neuroradiology.

  5. Assessment of ultrasonography and computed tomography for the evaluation of unilateral orbital disease in dogs.

    PubMed

    Boroffka, Susanne A E B; Verbruggen, Anne-Marie; Grinwis, Guy C M; Voorhout, George; Barthez, Paul Y

    2007-03-01

    To describe clinical, ultrasonographic, and computed tomographic (CT) features of confirmed neoplastic and nonneoplastic disease in dogs with unilateral orbital diseases, determine criteria to differentiate between the 2 conditions, and assess the relative value of ultrasonography and CT for the differential diagnosis of these 2 conditions. Prospective study. 29 dogs with unilateral neoplastic orbital disease and 16 dogs with unilateral nonneoplastic orbital disease. Clinical history and results of physical and ophthalmologic examinations were recorded. Ultrasonographic and CT images were evaluated, and discriminating factors were identified to differentiate neoplastic from nonneoplastic diseases. Diagnostic value of ultrasonography and CT was assessed. Dogs with neoplastic disease were significantly older; had clinical signs for a longer time before initial examination; had more progressive onset of clinical signs; and more frequently had protrusion of the nictitating membrane, fever, and anorexia. The most discriminating factor for both imaging modalities was delineation of the margins (odds ratio was 41.7 for ultrasonography and 45 for CT), with neoplastic lesions clearly delineated more often. Ultrasonographically, neoplastic lesions were more frequently hypoechoic and homogeneous, with indentation of the globe and bone involvement evident more frequently than for nonneoplastic lesions. Mineralization was detected only with neoplasia. Fluctuant fluid was seen more frequently in dogs with nonneoplastic disease. Computed tomography more frequently revealed extraorbital involvement. Diagnostic value was similar for both imaging modalities. Ultrasonography and CT are valuable imaging modalities to assist in differentiating neoplastic from nonneoplastic unilateral orbital disease in dogs.

  6. Routine Ultrasound and Limited Computed Tomography for the Diagnosis of Acute Appendicitis

    PubMed Central

    Wiersma, Fraukje; Bakker, Rutger F. R.; Merkus, Jos W. S.; Breslau, Paul J.; Hamming, Jaap F.

    2010-01-01

    Background Acute appendicitis continues to be a challenging diagnosis. Preoperative radiological imaging using ultrasound (US) or computed tomography (CT) has gained popularity as it may offer a more accurate diagnosis than classic clinical evaluation. The optimal implementation of these diagnostic modalities has yet to be established. The aim of the present study was to investigate a diagnostic pathway that uses routine US, limited CT, and clinical re-evaluation for patients with acute appendicitis. Methods A prospective analysis was performed of all patients presenting with acute abdominal pain at the emergency department from June 2005 until July 2006 using a structured diagnosis and management flowchart. Daily practice was mimicked, while ensuring a valid assessment of clinical and radiological diagnostic accuracies and the effect they had on patient management. Results A total of 802 patients were included in this analysis. Additional radiological imaging was performed in 96.3% of patients with suspected appendicitis (n = 164). Use of CT was kept to a minimum (17.9%), with a US:CT ratio of approximately 6:1. Positive and negative predictive values for the clinical diagnosis of appendicitis were 63 and 98%, respectively; for US 94 and 97%, respectively; and for CT 100 and 100%, respectively. The negative appendicitis rate was 3.3%, the perforation rate was 23.5%, and the missed perforated appendicitis rate was 3.4%. No (diagnostic) laparoscopies were performed. Conclusions A diagnostic pathway using routine US, limited CT, and clinical re-evaluation for patients with acute abdominal pain can provide excellent results for the diagnosis and treatment of appendicitis. PMID:20582544

  7. FDG-PET/CT for treatment response assessment in head and neck squamous cell carcinoma: a systematic review and meta-analysis of diagnostic performance.

    PubMed

    Helsen, Nils; Van den Wyngaert, Tim; Carp, Laurens; Stroobants, Sigrid

    2018-06-01

    18-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) is increasingly used to evaluate treatment response in head and neck squamous cell carcinoma (HNSCC). This analysis assessed the diagnostic value of FDG-PET/CT in detecting nodal disease within 6 months after treatment, considering patient and disease characteristics. A systematic review was performed using the MEDLINE and Web of Knowledge databases. The results were pooled using a bivariate random effects model of the sensitivity and specificity. Out of 22 identified studies, a meta-analysis of 20 studies (1293 patients) was performed. The pooled estimates of sensitivity, specificity and diagnostic odds ratio (with 95% CI) were 85% (76-91%), 93% (89-96%) and 76 (35-165), respectively. With the prevalence set at 10%, the positive and negative predictive values were 58% and 98%. There was significant heterogeneity between the trials (p < 0.001). HPV positive tumors were associated with lower sensitivity (75% vs 89%; p = 0.01) and specificity (87% vs 95%; p < 0.005). FDG-PET/CT within 6 months after (chemo)radiotherapy in HNSCC patients is a reliable method for ruling out residual/recurrent nodal disease and obviates the need for therapeutic intervention. However, FDG-PET/CT may be less reliable in HPV positive tumors and the optimal surveillance strategy remains to be determined.

  8. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT.

    PubMed

    Cho, S H; Sung, Y M; Kim, M S

    2012-10-01

    The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images.

  9. Anastomotic leakage after colorectal surgery: diagnostic accuracy of CT.

    PubMed

    Kauv, Paul; Benadjaoud, Samir; Curis, Emmanuel; Boulay-Coletta, Isabelle; Loriau, Jerome; Zins, Marc

    2015-12-01

    To evaluate the diagnostic accuracy of CT in postoperative colorectal anastomotic leakage (AL). Two independent blinded radiologists reviewed 153 CTs performed for suspected AL within 60 days after surgery in 131 consecutive patients, with (n = 58) or without (n = 95) retrograde contrast enema (RCE). Results were compared to original interpretations. The reference standard was reoperation or consensus (a radiologist and a surgeon) regarding clinical, laboratory, radiological, and follow-up data after medical treatment. AL was confirmed in 34/131 patients. For the two reviewers and original interpretation, sensitivity of CT was 82 %, 87 %, and 71 %, respectively; specificity was 84 %, 84 %, and 92 %. RCE significantly increased the positive predictive value (from 40 % to 88 %, P = 0.0009; 41 % to 92 %, P = 0.0016; and 40 % to 100 %, P = 0.0006). Contrast extravasation was the most sensitive (reviewers, 83 % and 83 %) and specific (97 % and 97 %) sign and was significantly associated with AL by univariate analysis (P < 0.0001 and P < 0.0001). By multivariate analysis with recursive partitioning, CT with RCE was accurate to confirm or rule out AL with contrast extravasation. CT with RCE is accurate for diagnosing postoperative colorectal AL. Contrast extravasation is the most reliable sign. RCE should be performed during CT for suspected AL. • CT accurately diagnosed clinically suspected colorectal AL and showed good interobserver agreement • Contrast extravasation was the most sensitive and specific CT sign • Retrograde contrast enema during CT improved positive predictive value • Retrograde contrast enema decreased false-negative or indeterminate original CT interpretations.

  10. Clinical significance of FDG-PET/CT at the postoperative surveillance in the breast cancer patients.

    PubMed

    Jung, Na Young; Yoo, Ie Ryung; Kang, Bong Joo; Kim, Sung Hun; Chae, Byung Joo; Seo, Ye Young

    2016-01-01

    We evaluated the clinical role of [(18)F]-2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT) compared with conventional imaging (CI) to detect locoregional recurrence or distant metastasis during postoperative surveillance of patients with breast cancer. We included 1,819 examinations of 1,161 patients, who underwent FDG-PET/CT and CI, including mammography, breast ultrasound, whole-body bone scintigraphy, and chest radiography for postoperative surveillance. All patients had a history of surgery with or without adjuvant treatment due to more than stage II breast cancer between November 2003 and November 2009. We evaluated the diagnostic performance of CI, FDG-PET/CT, and combined CI and FDG-PET/CT for detecting locoregional recurrence, distant metastasis, and incidental cancer. We also analyzed false-positive and false-negative results in both FDG-PET/CT and CI. Sensitivity, specificity, positive predictive value, and negative predictive value of CI were 75.4, 98.7, 93.4, and 94.3 %. Those of FDG-PET/CT were 97.5, 98.8, 95.4, and 99.4 %. Those of the combined results were 98.6, 98.2, 96.7, and 99.7 %. Sensitivity of FDG-PET/CT was significantly higher than that of CI (P < 0.05). Sensitivity of combined CI and FDG-PET/CT results improved, but they were not significantly different from those of FDG-PET/CT alone (P = 0.43). Seventeen false-positive and nine false-negative cases were detected with FDG-PET/CT, and 19 false-positive and 88 false-negative cases were detected with CI. FDG-PET/CT is considered as an acceptable diagnostic imaging modality for postoperative surveillance of patients with breast cancer.

  11. Comparison of DWI and 18F-FDG PET/CT for assessing preoperative N-staging in gastric cancer: evidence from a meta-analysis.

    PubMed

    Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo

    2017-10-13

    The diagnostic values of diffusion weighted imaging (DWI) and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73-0.85), 0.69 (0.61-0.77), and 0.81 (0.77-0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39-0.64), 0.88 (0.61-0.97), and 0.66 (0.62-0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18 F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18 F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18 F-FDG PET/CT had limited utility for preoperative N-staging.

  12. Image quality assessment for CT used on small animals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cisneros, Isabela Paredes, E-mail: iparedesc@unal.edu.co; Agulles-Pedrós, Luis, E-mail: lagullesp@unal.edu.co

    Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters usingmore » an acrylic phantom and then, using the computational tool MATLAB, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.« less

  13. Image quality assessment for CT used on small animals

    NASA Astrophysics Data System (ADS)

    Cisneros, Isabela Paredes; Agulles-Pedrós, Luis

    2016-07-01

    Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters using an acrylic phantom and then, using the computational tool MatLab, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.

  14. Sci—Thur PM: Imaging — 06: Canada's National Computed Tomography (CT) Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wardlaw, GM; Martel, N; Blackler, W

    2014-08-15

    The value of computed tomography (CT) in medical imaging is reflected in its' increased use and availability since the early 1990's; however, given CT's relatively larger exposures (vs. planar x-ray) greater care must be taken to ensure that CT procedures are optimised in terms of providing the smallest dose possible while maintaining sufficient diagnostic image quality. The development of CT Diagnostic Reference Levels (DRLs) supports this process. DRLs have been suggested/supported by international/national bodies since the early 1990's and widely adopted elsewhere, but not on a national basis in Canada. Essentially, CT DRLs provide guidance on what is considered goodmore » practice for common CT exams, but require a representative sample of CT examination data to make any recommendations. Canada's National CT Survey project, in collaboration with provincial/territorial authorities, has collected a large national sample of CT practice data for 7 common examinations (with associated clinical indications) of both adult and pediatric patients. Following completion of data entry into a common database, a survey summary report and recommendations will be made on CT DRLs from this data. It is hoped that these can then be used by local regions to promote CT practice optimisation and support any dose reduction initiatives.« less

  15. Hybrid-fusion SPECT/CT systems in parathyroid adenoma: Technological improvements and added clinical diagnostic value.

    PubMed

    Wong, K K; Chondrogiannis, S; Bowles, H; Fuster, D; Sánchez, N; Rampin, L; Rubello, D

    Nuclear medicine traditionally employs planar and single photon emission computed tomography (SPECT) imaging techniques to depict the biodistribution of radiotracers for the diagnostic investigation of a range of disorders of endocrine gland function. The usefulness of combining functional information with anatomy derived from computed tomography (CT), magnetic resonance imaging (MRI), and high resolution ultrasound (US), has long been appreciated, either using visual side-by-side correlation, or software-based co-registration. The emergence of hybrid SPECT/CT camera technology now allows the simultaneous acquisition of combined multi-modality imaging, with seamless fusion of 3D volume datasets. Thus, it is not surprising that there is growing literature describing the many advantages that contemporary SPECT/CT technology brings to radionuclide investigation of endocrine disorders, showing potential advantages for the pre-operative locating of the parathyroid adenoma using a minimally invasive surgical approach, especially in the presence of ectopic glands and in multiglandular disease. In conclusion, hybrid SPECT/CT imaging has become an essential tool to ensure the most accurate diagnostic in the management of patients with hyperparathyroidism. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  16. Cross-modality PET/CT and contrast-enhanced CT imaging for pancreatic cancer

    PubMed Central

    Zhang, Jian; Zuo, Chang-Jing; Jia, Ning-Yang; Wang, Jian-Hua; Hu, Sheng-Ping; Yu, Zhong-Fei; Zheng, Yuan; Zhang, An-Yu; Feng, Xiao-Yuan

    2015-01-01

    AIM: To explore the diagnostic value of the cross-modality fusion images provided by positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT (CECT) for pancreatic cancer (PC). METHODS: Data from 70 patients with pancreatic lesions who underwent CECT and PET/CT examinations at our hospital from August 2010 to October 2012 were analyzed. PET/CECT for the cross-modality image fusion was obtained using TureD software. The diagnostic efficiencies of PET/CT, CECT and PET/CECT were calculated and compared with each other using a χ2 test. P < 0.05 was considered to indicate statistical significance. RESULTS: Of the total 70 patients, 50 had PC and 20 had benign lesions. The differences in the sensitivity, negative predictive value (NPV), and accuracy between CECT and PET/CECT in detecting PC were statistically significant (P < 0.05 for each). In 15 of the 31 patients with PC who underwent a surgical operation, peripancreatic vessel invasion was verified. The differences in the sensitivity, positive predictive value, NPV, and accuracy of CECT vs PET/CT and PET/CECT vs PET/CT in diagnosing peripancreatic vessel invasion were statistically significant (P < 0.05 for each). In 19 of the 31 patients with PC who underwent a surgical operation, regional lymph node metastasis was verified by postsurgical histology. There was no statistically significant difference among the three methods in detecting regional lymph node metastasis (P > 0.05 for each). In 17 of the 50 patients with PC confirmed by histology or clinical follow-up, distant metastasis was confirmed. The differences in the sensitivity and NPV between CECT and PET/CECT in detecting distant metastasis were statistically significant (P < 0.05 for each). CONCLUSION: Cross-modality image fusion of PET/CT and CECT is a convenient and effective method that can be used to diagnose and stage PC, compensating for the defects of PET/CT and CECT when they are conducted individually. PMID:25780297

  17. Risk-related 18F-FDG PET/CT and new diagnostic strategies in patients with solitary pulmonary nodule: the ITALIAN multicenter trial.

    PubMed

    Spadafora, Marco; Pace, Leonardo; Evangelista, Laura; Mansi, Luigi; Del Prete, Francesco; Saladini, Giorgio; Miletto, Paolo; Fanti, Stefano; Del Vecchio, Silvana; Guerra, Luca; Pepe, Giovanna; Peluso, Giuseppina; Nicolai, Emanuele; Storto, Giovanni; Ferdeghini, Marco; Giordano, Alessandro; Farsad, Mohsen; Schillaci, Orazio; Gridelli, Cesare; Cuocolo, Alberto

    2018-05-05

    Diagnosis of solitary pulmonary nodule (SPN) is an important public health issue and 18 F-FDG PET/CT has proven to be more effective than CT alone. Pre-test risk stratification and clinical presentation of SPN could affect the diagnostic strategy. A relevant issue is whether thoracic segmental (s)-PET/CT could be implemented in patients with SPN. This retrospective multicenter study compared the results of FDG whole-body (wb)-PET/CT to those of s-PET/CT. 18 F-FDG PET/CT of 502 patients, stratified for pre-test cancer risk, were retrospectively analyzed. The thoracic part of wb-PET/CT, considered s-PET/CT, was compared to wb-PET/CT. Clinical and PET/CT variables were investigated for SPN characterization as well as for identification of patients in whom s-PET/CT could be performed. Histopathology or follow-up data were used as a reference. In the study population, 36% had malignant, 35% benign, and 29% indeterminate SPN. 18 F-FDG uptake indicative of thoracic and extra-thoracic lesions was detectable in 13% and 3% of the patients. All patients with extra-thoracic metastases (n = 13) had thoracic lymph node involvement and highest 18 F-FDG uptake at level of SPN (negative predictive value 100%). Compared to wb-PET/CT, s-PET/CT could save about 2/3 of 18 F-FDG dose, radiation exposure or scan-time, without affecting the clinical impact of PET/CT. Pre-test probability of malignancy can guide the diagnostic strategy of 18 FDG-PET/CT in patients with SPN. In subjects with low-intermediate pretest probability s-PET/CT imaging might be planned in advance, while in those at high risk and with thoracic lymph node involvement a wb-PET/CT is necessary.

  18. SU-E-J-218: Novel Validation Paradigm of MRI to CT Deformation of Prostate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padgett, K; University of Miami School of Medicine - Radiology, Miami, FL; Pirozzi, S

    2015-06-15

    Purpose: Deformable registration algorithms are inherently difficult to characterize in the multi-modality setting due to a significant differences in the characteristics of the different modalities (CT and MRI) as well as tissue deformations. We present a unique paradigm where this is overcome by utilizing a planning-MRI acquired within an hour of the planning-CT serving as a surrogate for quantifying MRI to CT deformation by eliminating the issues of multi-modality comparisons. Methods: For nine subjects, T2 fast-spin-echo images were acquired at two different time points, the first several weeks prior to planning (diagnostic-MRI) and the second on the same day asmore » the planning-CT (planning-MRI). Significant effort in patient positioning and bowel/bladder preparation was undertaken to minimize distortion of the prostate in all datasets. The diagnostic-MRI was rigidly and deformably aligned to the planning-CT utilizing a commercially available deformable registration algorithm synthesized from local registrations. Additionally, the quality of rigid alignment was ranked by an imaging physicist. The distances between corresponding anatomical landmarks on rigid and deformed registrations (diagnostic-MR to planning-CT) were evaluated. Results: It was discovered that in cases where the rigid registration was of acceptable quality the deformable registration didn’t improve the alignment, this was true of all metrics employed. If the analysis is separated into cases where the rigid alignment was ranked as unacceptable the deformable registration significantly improved the alignment, 4.62mm residual error in landmarks as compared to 5.72mm residual error in rigid alignments with a p-value of 0.0008. Conclusion: This paradigm provides an ideal testing ground for MR to CT deformable registration algorithms by allowing for inter-modality comparisons of multi-modality registrations. Consistent positioning, bowel and bladder preparation may Result in higher quality rigid registrations than typically achieved which limits the impact of deformable registrations. In this study cases where significant differences exist, deformable registrations provide significant value.« less

  19. A 30-Min Nucleic Acid Amplification Point-of-Care Test for Genital Chlamydia trachomatis Infection in Women: A Prospective, Multi-center Study of Diagnostic Accuracy.

    PubMed

    Harding-Esch, E M; Cousins, E C; Chow, S-L C; Phillips, L T; Hall, C L; Cooper, N; Fuller, S S; Nori, A V; Patel, R; Thomas-William, S; Whitlock, G; Edwards, S J E; Green, M; Clarkson, J; Arlett, B; Dunbar, J K; Lowndes, C M; Sadiq, S T

    2018-02-01

    Rapid Point-Of-Care Tests for Chlamydia trachomatis (CT) may reduce onward transmission and reproductive sexual health (RSH) sequelae by reducing turnaround times between diagnosis and treatment. The io® single module system (Atlas Genetics Ltd.) runs clinical samples through a nucleic acid amplification test (NAAT)-based CT cartridge, delivering results in 30min. Prospective diagnostic accuracy study of the io® CT-assay in four UK Genito-Urinary Medicine (GUM)/RSH clinics on additional-to-routine self-collected vulvovaginal swabs. Samples were tested "fresh" within 10days of collection, or "frozen" at -80°C for later testing. Participant characteristics were collected to assess risk factors associated with CT infection. CT prevalence was 7.2% (51/709) overall. Sensitivity, specificity, positive and negative predictive values of the io® CT assay were, respectively, 96.1% (95% Confidence Interval (CI): 86.5-99.5), 97.7% (95%CI: 96.3-98.7), 76.6% (95%CI: 64.3-86.2) and 99.7% (95%CI: 98.9-100). The only risk factor associated with CT infection was being a sexual contact of an individual with CT. The io® CT-assay is a 30-min, fully automated, high-performing NAAT currently CE-marked for CT diagnosis in women, making it a highly promising diagnostic to enable specific treatment, initiation of partner notification and appropriately intensive health promotion at the point of care. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Diagnostic accuracy of laparoscopy following computed tomography (CT) scanning for assessing the resectability with curative intent in pancreatic and periampullary cancer.

    PubMed

    Allen, Victoria B; Gurusamy, Kurinchi Selvan; Takwoingi, Yemisi; Kalia, Amun; Davidson, Brian R

    2016-07-06

    Surgical resection is the only potentially curative treatment for pancreatic and periampullary cancer. A considerable proportion of patients undergo unnecessary laparotomy because of underestimation of the extent of the cancer on computed tomography (CT) scanning. Laparoscopy can detect metastases not visualised on CT scanning, enabling better assessment of the spread of cancer (staging of cancer). This is an update to a previous Cochrane Review published in 2013 evaluating the role of diagnostic laparoscopy in assessing the resectability with curative intent in people with pancreatic and periampullary cancer. To determine the diagnostic accuracy of diagnostic laparoscopy performed as an add-on test to CT scanning in the assessment of curative resectability in pancreatic and periampullary cancer. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE via PubMed, EMBASE via OvidSP (from inception to 15 May 2016), and Science Citation Index Expanded (from 1980 to 15 May 2016). We included diagnostic accuracy studies of diagnostic laparoscopy in people with potentially resectable pancreatic and periampullary cancer on CT scan, where confirmation of liver or peritoneal involvement was by histopathological examination of suspicious (liver or peritoneal) lesions obtained at diagnostic laparoscopy or laparotomy. We accepted any criteria of resectability used in the studies. We included studies irrespective of language, publication status, or study design (prospective or retrospective). We excluded case-control studies. Two review authors independently performed data extraction and quality assessment using the QUADAS-2 tool. The specificity of diagnostic laparoscopy in all studies was 1 because there were no false positives since laparoscopy and the reference standard are one and the same if histological examination after diagnostic laparoscopy is positive. The sensitivities were therefore meta-analysed using a univariate random-effects logistic regression model. The probability of unresectability in people who had a negative laparoscopy (post-test probability for people with a negative test result) was calculated using the median probability of unresectability (pre-test probability) from the included studies, and the negative likelihood ratio derived from the model (specificity of 1 assumed). The difference between the pre-test and post-test probabilities gave the overall added value of diagnostic laparoscopy compared to the standard practice of CT scan staging alone. We included 16 studies with a total of 1146 participants in the meta-analysis. Only one study including 52 participants had a low risk of bias and low applicability concern in the patient selection domain. The median pre-test probability of unresectable disease after CT scanning across studies was 41.4% (that is 41 out of 100 participants who had resectable cancer after CT scan were found to have unresectable disease on laparotomy). The summary sensitivity of diagnostic laparoscopy was 64.4% (95% confidence interval (CI) 50.1% to 76.6%). Assuming a pre-test probability of 41.4%, the post-test probability of unresectable disease for participants with a negative test result was 0.20 (95% CI 0.15 to 0.27). This indicates that if a person is said to have resectable disease after diagnostic laparoscopy and CT scan, there is a 20% probability that their cancer will be unresectable compared to a 41% probability for those receiving CT alone.A subgroup analysis of people with pancreatic cancer gave a summary sensitivity of 67.9% (95% CI 41.1% to 86.5%). The post-test probability of unresectable disease after being considered resectable on both CT and diagnostic laparoscopy was 18% compared to 40.0% for those receiving CT alone. Diagnostic laparoscopy may decrease the rate of unnecessary laparotomy in people with pancreatic and periampullary cancer found to have resectable disease on CT scan. On average, using diagnostic laparoscopy with biopsy and histopathological confirmation of suspicious lesions prior to laparotomy would avoid 21 unnecessary laparotomies in 100 people in whom resection of cancer with curative intent is planned.

  1. Comparison of Dynamic Contrast-Enhanced MRI and PET/CT in the Evaluation of Laryngeal Cancer After Inadequate CT Results.

    PubMed

    Citil, Serdal; Dogan, Serap; Atilgan, Hasan Ikbal; Menzilcioglu, Mehmet Sait; Sahin, Tuna; Abdulrezzak, Ummuhan; Duymus, Mahmut; Ozturk, Mustafa

    2015-01-01

    To investigate the diagnostic value of dynamic magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) for laryngeal cancers after inadequate CT results. The study comprised 45 patients investigated for primary laryngeal cancer or recurrence-residue in which CT was considered inadequate. A mass was found in 20 patients. Dynamic MRI and PET/CT were compared for diagnosis of mass, lymph node involvement, recurrence and residue. The dynamic curves formed in dynamic MRI were investigated for diagnostic contributions. The sensitivity and specificity of the dynamic MRI, for supraglottic, glottic and subglottic location, was 100%, 80%, and 92%; 100%, 85%, and 100%, respectively. In PET/CT the sensitivity and specificity were 100% for all of those localizations. For lymph node involvement, the sensitivity of dynamic MRI and PET/CT was 100%, the specificity was 100% and 93%, respectively. For recurrence-residue, the sensitivity and specificity of dynamic MRI were 86% and 67%, respectively, with 100% sensitivity and specificity in PET/CT. The sensitivity of type A curve for detection of malignancy was 40%, and specificity was 100%. When type A and B curves were included, the sensitivity was 100%. For patients investigated for laryngeal cancer in which CT is considered inadequate, dynamic MRI or PET/CT is useful.

  2. Identification of Nasal Bone Fractures on Conventional Radiography and Facial CT: Comparison of the Diagnostic Accuracy in Different Imaging Modalities and Analysis of Interobserver Reliability.

    PubMed

    Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin

    2013-09-01

    There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee.

  3. Diagnostic significance of rib series in minor thorax trauma compared to plain chest film and computed tomography.

    PubMed

    Hoffstetter, Patrick; Dornia, Christian; Schäfer, Stephan; Wagner, Merle; Dendl, Lena M; Stroszczynski, Christian; Schreyer, Andreas G

    2014-01-01

    Rib series (RS) are a special radiological technique to improve the visualization of the bony parts of the chest. The aim of this study was to evaluate the diagnostic accuracy of rib series in minor thorax trauma. Retrospective study of 56 patients who received RS, 39 patients where additionally evaluated by plain chest film (PCF). All patients underwent a computed tomography (CT) of the chest. RS and PCF were re-read independently by three radiologists, the results were compared with the CT as goldstandard. Sensitivity, specificity, negative and positive predictive value were calculated. Significance in the differences of findings was determined by McNemar test, interobserver variability by Cohens kappa test. 56 patients were evaluated (34 men, 22 women, mean age =61 y.). In 22 patients one or more rib fracture could be identified by CT. In 18 of these cases (82%) the correct diagnosis was made by RS, in 16 cases (73%) the correct number of involved ribs was detected. These differences were significant (p = 0.03). Specificity was 100%, negative and positive predictive value were 85% and 100%. Kappa values for the interobserver agreement was 0.92-0.96. Sensitivity of PCF was 46% and was significantly lower (p = 0.008) compared to CT. Rib series does not seem to be an useful examination in evaluating minor thorax trauma. CT seems to be the method of choice to detect rib fractures, but the clinical value of the radiological proof has to be discussed and investigated in larger follow up studies.

  4. Age and sex based reference values for incidental coronary artery and thoracic aorta calcifications on routine clinical chest CT: a powerful tool to appreciate available imaging findings.

    PubMed

    Jairam, Pushpa M; de Jong, Pim A; Mali, Willem P Th M; Gondrie, Martijn J A; Jacobs, Peter C A; van der Graaf, Yolanda

    2014-08-01

    To establish age and gender specific reference values for incidental coronary artery and thoracic aorta calcification scores on routine diagnostic CT scans. These reference values can aid in structured reporting and interpretation of readily available imaging data by chest CT readers in routine practice. A random sample of 1572 (57% male, median age 61 years) was taken from a study population of 12,063 subjects who underwent diagnostic chest CT for non-cardiovascular indications between January 2002 and December 2005. Coronary artery and thoracic aorta calcifications were graded using a validated ordinal score. The 25th, 50th and 75th percentile cut points were calculated for the coronary artery and thoracic aorta calcification scores within each age/gender stratum. The 75th percentile cut points for coronary artery calcification scores were higher for men than for women across all age groups, with the exception of the lowest age group. The 75th percentile cut points for thoracic aorta calcifications scores were comparable for both genders across all age groups. Based on the obtained age and gender reference values a calculation tool is provided, that allows one to enter an individual's age, gender and calcification scores to obtain the corresponding estimated percentiles. The calculation tool as provided in this study can be used in daily practice by CT readers to examine whether a subject has high calcifications scores relative to others with the same age and gender. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    PubMed

    Delgado Oliva, F; Arlandis Guzman, S; Bonillo García, M; Broseta Rico, E; Boronat Tormo, F

    2016-10-01

    To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4-20ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3±7.01years (95% CI, 63.75-64.70); mean total PSA was 8.9±3.61ng/mL (95% CI, 8.67-9.13) and the mean prostate volume was 56.2±29cc (95% CI, 54.2-58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16% vs. 35%), and stage cT2 (43.5% vs. 66.6%), with a p value<0.05. Following the "core-by-core" analysis, the detection rates by core of CEUS-targeted biopsy versus randomized biopsy were: Global population (16% vs. 13%), stage cT1 (30.3% vs. 28%), and stage cT2 (48% vs. 37%), with a p value>0.05. The NNT for CEUS-targeted biopsy was 83.3. The low sensitivity, specificity, positive predictive and negative predictive values of gray scale-B-mode, PDUS and CEUS represent scant diagnostic performance of these variables in prostate cancer detection. Prostate cancer detection rates yielded by randomized biopsy were superior than the detection rate of targeted biopsy using B-mode, PDUS and CEUS; as a result, randomized biopsy versus CEUS-targeted biopsies cannot be excluded from biopsy strategy plans for the diagnosis of prostate cancer. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Added value of SPECT/spiral CT versus SPECT or CT alone in diagnosing solitary skeletal lesions.

    PubMed

    Zhang, Yiqiu; Li, Beilei; Shi, Hongcheng; Yu, Haojun; Gu, Yushen; Xiu, Yan

    2017-08-14

    The aim of this study was to investigate the added value of SPECT/spiral CT versus SPECT or CT alone in the differential diagnosis of solitary skeletal lesions. This was a retrospective study on a total of 69 patients who had a solitary skeletal "hot spot" that could not be definitively diagnosed using planar scintigraphy. Thus, SPECT/spiral CT was performed on the indeterminate lesions. SPECT, CT and SPECT/spiral CT images were independently interpreted by two experienced doctors who have both identification of CT and nuclear medicine. Each lesion was graded on a 4-point diagnostic scale (1: benign, 2: likely benign, 3: likely malignant, 4: malignant). The final diagnosis of each lesion was based on pathological confirmation after surgery within 3 weeks of the bone scan. Final diagnoses based on the pathological results revealed that 43 of the 69 patients were diagnosed with malignancy, and the remaining 26 patients were diagnosed as having benign lesions. For SPECT and CT scans, both of the reviewers rated 55.1 % (38/69) and 37.7 % (26/69) of lesions as equivocal, with the help of SPECT/CT, 33.3 % (23/69) of lesions were rated as equivocal. The diagnostic accuracies of SPECT, CT alone and SPECT/CT were 66.7 % (46/69) ,82.6 % (57/69) and 85.5 %(59/69), respectively. The kappa scores for the degree of agreement between SPECT, CT alone or SPECT/CT with pathological results were 0.185 (p = 0.054) , 0.612 (p < 0.001) and 0.671 (p < 0.001), respectively. Compared with SPECT or imaging alone, SPECT/spiral CT imaging was more accurate and valuable in the differential diagnosis of solitary skeletal lesions and resulted in significantly fewer equivocal findings.

  7. Combined single photon emission computerized tomography and conventional computerized tomography: Clinical value for the shoulder surgeons?

    PubMed Central

    Hirschmann, Michael T.; Schmid, Rahel; Dhawan, Ranju; Skarvan, Jiri; Rasch, Helmut; Friederich, Niklaus F.; Emery, Roger

    2011-01-01

    With the cases described, we strive to introduce single photon emission computerized tomography in combination with conventional computer tomography (SPECT/CT) to shoulder surgeons, illustrate the possible clinical value it may offer as new diagnostic radiologic modality, and discuss its limitations. SPECT/CT may facilitate the establishment of diagnosis, process of decision making, and further treatment for complex shoulder pathologies. Some of these advantages were highlighted in cases that are frequently seen in most shoulder clinics. PMID:22058640

  8. Implementation of Size-Dependent Local Diagnostic Reference Levels for CT Angiography.

    PubMed

    Boere, Hub; Eijsvoogel, Nienke G; Sailer, Anna M; Wildberger, Joachim E; de Haan, Michiel W; Das, Marco; Jeukens, Cecile R L P N

    2018-05-01

    Diagnostic reference levels (DRLs) are established for standard-sized patients; however, patient dose in CT depends on patient size. The purpose of this study was to introduce a method for setting size-dependent local diagnostic reference levels (LDRLs) and to evaluate these LDRLs in comparison with size-independent LDRLs and with respect to image quality. One hundred eighty-four aortic CT angiography (CTA) examinations performed on either a second-generation or third-generation dual-source CT scanner were included; we refer to the second-generation dual-source CT scanner as "CT1" and the third-generation dual-source CT scanner as "CT2." The volume CT dose index (CTDI vol ) and patient diameter (i.e., the water-equivalent diameter) were retrieved by dose-monitoring software. Size-dependent DRLs based on a linear regression of the CTDI vol versus patient size were set by scanner type. Size-independent DRLs were set by the 5th and 95th percentiles of the CTDI vol values. Objective image quality was assessed using the signal-to-noise ratio (SNR), and subjective image quality was assessed using a 4-point Likert scale. The CTDI vol depended on patient size and scanner type (R 2 = 0.72 and 0.78, respectively; slope = 0.05 and 0.02 mGy/mm; p < 0.001). Of the outliers identified by size-independent DRLs, 30% (CT1) and 67% (CT2) were adequately dosed when considering patient size. Alternatively, 30% (CT1) and 70% (CT2) of the outliers found with size-dependent DRLs were not identified using size-independent DRLs. A negative correlation was found between SNR and CTDI vol (R 2 = 0.36 for CT1 and 0.45 for CT2). However, all outliers had a subjective image quality score of sufficient or better. We introduce a method for setting size-dependent LDRLs in CTA. Size-dependent LDRLs are relevant for assessing the appropriateness of the radiation dose for an individual patient on a specific CT scanner.

  9. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT

    PubMed Central

    Cho, S H; Sung, Y M; Kim, M S

    2012-01-01

    Objective The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. Methods 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. Results 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Conclusion Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images. PMID:22514102

  10. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guidemore » provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.« less

  11. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    NASA Astrophysics Data System (ADS)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-11-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  12. Evaluation of diagnostic value of CT scan, physical examination and ultrasound based on pathological findings in patients with pelvic masses.

    PubMed

    Firoozabadi, Razieh Dehghani; Karimi Zarchi, Mojgan; Mansurian, Hamid Reza; Moghadam, Bita Rafiei; Teimoori, Soraya; Naseri, Ali

    2011-01-01

    Because benign and malignant cervical and ovarian masses occur with different percentages in different age groups, the importance of primary diagnosis and selection of a suitable surgical procedure is underlined. Diagnosis of pelvic masses is carried out using ultrasound, physical examination, CT scan and MRI. The objective of this study is to evaluate the diagnostic value of CT scan in pelvic masses in comparison with physical examination-ultrasound based on pathology of the lesion in patients undergoing laparotomic surgery. This analytic-descriptive study focused on age, sonographic findings, physical examinations, CT scan and pathological findings in 139 patients with pelvic mass, gathered with questionnaires and statistically analayzed using the SPSS software programme. Of 139 patients with pelvic mass (patients aged from 17 to 75 years old), 62 (44%) cases were diagnosed as benign and 77 (55.4%) as malignant; among them malignant tratoma serocyst adenocarsinoma with 33 (23.7%) cases and benign myoma with 21 (15.2%) cases comprised the most frequent cases. The sensitivity and specificity of sonography-physical examination were 51.9% and 87.9% respectively and the sensitivity and specificity of CT scan images were 79.2% and 91.6% respectively. It was shown that CT scan images were more consistant with pathological findings in predicting appropriate surgical procedures than do sonography-physical examinations. The sensitivity of CT scan is far higher than that of sonography-physical examination in the diagnosis of pelvic mass malignancy.

  13. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    PubMed Central

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images, as compared to the reference magnetic resonance images. The difference in accuracy was statistically significant (P = 0.02). CONCLUSION: New generation CT scanner, using high resolution MPR images, represents a reliable diagnostic tool in assessment of loco-regional and whole body staging of advanced rectal cancer, especially in patients with MRI contraindications. PMID:27239115

  14. Usage of CT data in biomechanical research

    NASA Astrophysics Data System (ADS)

    Safonov, Roman A.; Golyadkina, Anastasiya A.; Kirillova, Irina V.; Kossovich, Leonid Y.

    2017-02-01

    Object of study: The investigation is focused on development of personalized medicine. The determination of mechanical properties of bone tissues based on in vivo data was considered. Methods: CT, MRI, natural experiments on versatile test machine Instron 5944, numerical experiments using Python programs. Results: The medical diagnostics methods, which allows determination of mechanical properties of bone tissues based on in vivo data. The series of experiments to define the values of mechanical parameters of bone tissues. For one and the same sample, computed tomography (CT), magnetic resonance imaging (MRI), ultrasonic investigations and mechanical experiments on single-column test machine Instron 5944 were carried out. The computer program for comparison of CT and MRI images was created. The grayscale values in the same points of the samples were determined on both CT and MRI images. The Haunsfield grayscale values were used to determine rigidity (Young module) and tensile strength of the samples. The obtained data was compared to natural experiments results for verification.

  15. Comparison of DWI and 18F-FDG PET/CT for assessing preoperative N-staging in gastric cancer: evidence from a meta-analysis

    PubMed Central

    Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo

    2017-01-01

    The diagnostic values of diffusion weighted imaging (DWI) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73–0.85), 0.69 (0.61–0.77), and 0.81 (0.77–0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39–0.64), 0.88 (0.61–0.97), and 0.66 (0.62–0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18F-FDG PET/CT had limited utility for preoperative N-staging. PMID:29137440

  16. [Study of testicular cancer gene expression in samples of oral leukoplakia and squamous cell carcinoma of the mouth].

    PubMed

    Skorodumova, L O; Muraev, A A; Zakharova, E S; Shepelev, M V; Korobko, I V; Zaderenko, I A; Ivanov, S Iu; Gnuchev, N V; Georgiev, G P; Larin, S S

    2012-01-01

    Cancer-testis (CT) antigens are normally expressed mostly in human germ cells, there is also an aberrant expression in some tumor cells. This expression profile makes them potential tumor growth biomarkers and a promising target for tumor immunotherapy. Specificity of CT genes expression in oral malignant and potentially malignant diseases, e.g. oral leukoplakia, is not yet studied. Data on CT genes expression profile in leukoplakia would allow developing new diagnostic methods with potential value for immunotherapy and prophylaxis of leukoplakia malignization. In our study we compared CT genes expression in normal oral mucosa, oral leukoplakia and oral squamous cell carcinoma. We are the first to describe CT genes expression in oral leukoplakia without dysplasia. This findings make impossible differential diagnosis of oral leukoplakia and squamous cell carcinoma on the basis of CT genes expression. The prognostic value of CT genes expression is still unclear, therefore the longitudinal studies are necessary.

  17. Time-Resolved C-Arm Computed Tomographic Angiography Derived From Computed Tomographic Perfusion Acquisition: New Capability for One-Stop-Shop Acute Ischemic Stroke Treatment in the Angiosuite.

    PubMed

    Yang, Pengfei; Niu, Kai; Wu, Yijing; Struffert, Tobias; Dorfler, Arnd; Schafer, Sebastian; Royalty, Kevin; Strother, Charles; Chen, Guang-Hong

    2015-12-01

    Multimodal imaging using cone beam C-arm computed tomography (CT) may shorten the delay from ictus to revascularization for acute ischemic stroke patients with a large vessel occlusion. Largely because of limited temporal resolution, reconstruction of time-resolved CT angiography (CTA) from these systems has not yielded satisfactory results. We evaluated the image quality and diagnostic value of time-resolved C-arm CTA reconstructed using novel image processing algorithms. Studies were done under an Institutional Review Board approved protocol. Postprocessing of data from 21 C-arm CT dynamic perfusion acquisitions from 17 patients with acute ischemic stroke were done to derive time-resolved C-arm CTA images. Two observers independently evaluated image quality and diagnostic content for each case. ICC and receiver-operating characteristic analysis were performed to evaluate interobserver agreement and diagnostic value of this novel imaging modality. Time-resolved C-arm CTA images were successfully generated from 20 data sets (95.2%, 20/21). Two observers agreed well that the image quality for large cerebral arteries was good but was more limited for small cerebral arteries (distal to M1, A1, and P1). receiver-operating characteristic curves demonstrated excellent diagnostic value for detecting large vessel occlusions (area under the curve=0.987-1). Time-resolved CTAs derived from C-arm CT perfusion acquisitions provide high quality images that allowed accurate diagnosis of large vessel occlusions. Although image quality of smaller arteries in this study was not optimal ongoing modifications of the postprocessing algorithm will likely remove this limitation. Adding time-resolved C-arm CTAs to the capabilities of the angiography suite further enhances its suitability as a one-stop shop for care for patients with acute ischemic stroke. © 2015 American Heart Association, Inc.

  18. Diagnostic performance and radiation dose of lower extremity CT angiography using a 128-slice dual source CT at 80 kVp and high pitch.

    PubMed

    Kim, Jin Woo; Choo, Ki Seok; Jeon, Ung Bae; Kim, Tae Un; Hwang, Jae Yeon; Yeom, Jeong A; Jeong, Hee Seok; Choi, Yoon Young; Nam, Kyung Jin; Kim, Chang Won; Jeong, Dong Wook; Lim, Soo Jin

    2016-07-01

    Multi-detector computed tomography (MDCT) angiography is now used for the diagnosing patients with peripheral arterial disease. The dose of radiation is related to variable factors, such as tube current, tube voltage, and helical pitch. To assess the diagnostic performance and radiation dose of lower extremity CT angiography (CTA) using a 128-slice dual source CT at 80 kVp and high pitch in patients with critical limb ischemia (CLI). Twenty-eight patients (mean, 64.1 years; range, 39-80 years) with CLI were enrolled in this retrospective study and underwent CTA using a 128-slice dual source CT at 80 kVp and high pitch and subsequent intra-arterial digital subtraction angiography (DSA), which was used as a reference standard for assessing diagnostic performance. For arterial segments with significant disease (>50% stenosis), overall sensitivity, specificity, and accuracy of lower extremity CTA were 94.8% (95% CI, 91.7-98.0%), 91.5% (95% CI, 87.7-95.2%), and 93.1% (95% CI, 90.6-95.6%), respectively, and its positive and negative predictive values were 91.0% (95% CI, 87.1-95.0%), and 95.1% (95% CI, 92.1-98.1%), respectively. Mean radiation dose delivered to lower extremities was 266.6 mGy.cm. Lower extremity CTA using a 128-slice dual source CT at 80 kVp and high pitch was found to have good diagnostic performance for the assessment of patients with CLI using an extremely low radiation dose. © The Foundation Acta Radiologica 2015.

  19. The influence of interpreters' professional background and experience on the interpretation of multimodality imaging of pulmonary lesions using 18F-3'-deoxy-fluorothymidine and 18F-fluorodeoxyglucose PET/CT.

    PubMed

    Xu, Bai-xuan; Liu, Chang-bin; Wang, Rui-min; Shao, Ming-zhe; Fu, Li-ping; Li, Yun-gang; Tian, Jia-he

    2013-01-01

    Based on the results of a recently accomplished multicenter clinical trial for the incremental value of a dual-tracer (18F-FDG and 18F-FLT), dual-modality (PET and CT) imaging in the differential diagnosis of pulmonary lesions, we investigate some issues that might affect the image interpretation and result reporting. The images were read in two separate sessions. Firstly the images were read and reported by physician(s) of the imaging center on completion of each PET/CT scanning. By the end of MCCT, all images collected during the trial were re-read by a collective of readers in an isolated, blinded, and independent way. One hundred sixty two patients successfully passed the data verification and entered into the final analysis. The primary reporting result showed adding 18F-FDG image information did not change the clinical performance much in sensitivity, specifity and accuracy, but the ratio between SUVFLT and SUVFDG did help the differentiation efficacy among the three subgroups of patients. The collective reviewing result showed the diagnostic achievement varied with reading strategies. ANOVA indicated significant differences among (18)F-FDG, (18)F-FLT in SUV (F = 14.239, p = 0.004). CT had almost the same diagnostic performance as 18F-FLT. When the 18F-FDG, 18F-FLT and CT images read in pair, both diagnostic sensitivity and specificity improved. The best diagnostic figures were obtained in full-modality strategy, when dual-tracer PET worked in combination with CT. With certain experience and training both radiologists and nuclear physicians are qualified to read and to achieve the similar diagnostic accuracy in PET/CT study. Making full use of modality combination and selecting right criteria seems more practical than professional back ground and personal experience in the new hybrid imaging technology, at least when novel tracer or application is concerned.

  20. Fusion of Computed Tomography and PROPELLER Diffusion-Weighted Magnetic Resonance Imaging for the Detection and Localization of Middle Ear Cholesteatoma.

    PubMed

    Locketz, Garrett D; Li, Peter M M C; Fischbein, Nancy J; Holdsworth, Samantha J; Blevins, Nikolas H

    2016-10-01

    A method to optimize imaging of cholesteatoma by combining the strengths of available modalities will improve diagnostic accuracy and help to target treatment. To assess whether fusing Periodically Rotated Overlapping Parallel Lines With Enhanced Reconstruction (PROPELLER) diffusion-weighted magnetic resonance imaging (DW-MRI) with corresponding temporal bone computed tomography (CT) images could increase cholesteatoma diagnostic and localization accuracy across 6 distinct anatomical regions of the temporal bone. Case series and preliminary technology evaluation of adults with preoperative temporal bone CT and PROPELLER DW-MRI scans who underwent surgery for clinically suggested cholesteatoma at a tertiary academic hospital. When cholesteatoma was encountered surgically, the precise location was recorded in a diagram of the middle ear and mastoid. For each patient, the 3 image data sets (CT, PROPELLER DW-MRI, and CT-MRI fusion) were reviewed in random order for the presence or absence of cholesteatoma by an investigator blinded to operative findings. If cholesteatoma was deemed present on review of each imaging modality, the location of the lesion was mapped presumptively. Image analysis was then compared with surgical findings. Twelve adults (5 women and 7 men; median [range] age, 45.5 [19-77] years) were included. The use of CT-MRI fusion had greater diagnostic sensitivity (0.88 vs 0.75), positive predictive value (0.88 vs 0.86), and negative predictive value (0.75 vs 0.60) than PROPELLER DW-MRI alone. Image fusion also showed increased overall localization accuracy when stratified across 6 distinct anatomical regions of the temporal bone (localization sensitivity and specificity, 0.76 and 0.98 for CT-MRI fusion vs 0.58 and 0.98 for PROPELLER DW-MRI). For PROPELLER DW-MRI, there were 15 true-positive, 45 true-negative, 1 false-positive, and 11 false-negative results; overall accuracy was 0.83. For CT-MRI fusion, there were 20 true-positive, 45 true-negative, 1 false-positive, and 6 false-negative results; overall accuracy was 0.90. The poor anatomical spatial resolution of DW-MRI makes precise localization of cholesteatoma within the middle ear and mastoid a diagnostic challenge. This study suggests that the bony anatomic detail obtained via CT coupled with the excellent sensitivity and specificity of PROPELLER DW-MRI for cholesteatoma can improve both preoperative identification and localization of disease over DW-MRI alone.

  1. Does positron emission tomography/computed tomography aid the diagnosis of prosthetic valve infective endocarditis?

    PubMed

    Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh

    2016-10-01

    A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Statistical distributions of ultra-low dose CT sinograms and their fundamental limits

    NASA Astrophysics Data System (ADS)

    Lee, Tzu-Cheng; Zhang, Ruoqiao; Alessio, Adam M.; Fu, Lin; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Low dose CT imaging is typically constrained to be diagnostic. However, there are applications for even lowerdose CT imaging, including image registration across multi-frame CT images and attenuation correction for PET/CT imaging. We define this as the ultra-low-dose (ULD) CT regime where the exposure level is a factor of 10 lower than current low-dose CT technique levels. In the ULD regime it is possible to use statistically-principled image reconstruction methods that make full use of the raw data information. Since most statistical based iterative reconstruction methods are based on the assumption of that post-log noise distribution is close to Poisson or Gaussian, our goal is to understand the statistical distribution of ULD CT data with different non-positivity correction methods, and to understand when iterative reconstruction methods may be effective in producing images that are useful for image registration or attenuation correction in PET/CT imaging. We first used phantom measurement and calibrated simulation to reveal how the noise distribution deviate from normal assumption under the ULD CT flux environment. In summary, our results indicate that there are three general regimes: (1) Diagnostic CT, where post-log data are well modeled by normal distribution. (2) Lowdose CT, where normal distribution remains a reasonable approximation and statistically-principled (post-log) methods that assume a normal distribution have an advantage. (3) An ULD regime that is photon-starved and the quadratic approximation is no longer effective. For instance, a total integral density of 4.8 (ideal pi for 24 cm of water) for 120kVp, 0.5mAs of radiation source is the maximum pi value where a definitive maximum likelihood value could be found. This leads to fundamental limits in the estimation of ULD CT data when using a standard data processing stream

  3. Post-therapy lesions in patients with non-Hodgkin's lymphoma characterized by 18F-FDG PET/CT-guided biopsy using automated robotic biopsy arm.

    PubMed

    Radhakrishnan, Renjith K; Mittal, Bhagwant R; Basher, Rajender K; Prakash, Gaurav; Malhotra, Pankaj; Kalra, Naveen; Das, Ashim

    2018-01-01

    The aim of this study was to analyse the positive predictive value (PPV) of post-therapy fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT performed for response or recurrence evaluation in patients with non-Hodgkin's lymphoma (NHL) and to appraise the diagnostic utility of F-FDG PET/CT-guided biopsy in this setting. A total of 17 patients with NHL showing F-FDG avid lesions in F-FDG PET/CT performed for response or recurrence assessment underwent F-FDG PET/CT-guided biopsy using automated robotic biopsy arm needle navigation technique. The objectives were analysed in reference to histopathology. In all, 15 of the 17 (88.5%) procedures yielded adequate representative tissue samples. Nine out of 15 lesions were positive for residual disease and the remaining revealed benign findings on histopathology. One patient with inconclusive biopsy underwent surgical resection and histopathology confirmed the presence of residual disease. PPV of theF-FDG PET/CT was observed to be 62.5% (10/16). F-FDG PET/CT for response evaluation in NHL possesses a low PPV and hence warrants histopathological correlation when F-FDG PET/CT findings influence management decision. Diagnostic yield of F-FDG PET/CT-guided biopsy is high and has the potential to reduce sampling errors.

  4. Assessment of real-time PCR cycle threshold values in Microsporum canis culture-positive and culture-negative cats in an animal shelter: a field study.

    PubMed

    Jacobson, Linda S; McIntyre, Lauren; Mykusz, Jenny

    2018-02-01

    Objectives Real-time PCR provides quantitative information, recorded as the cycle threshold (Ct) value, about the number of organisms detected in a diagnostic sample. The Ct value correlates with the number of copies of the target organism in an inversely proportional and exponential relationship. The aim of the study was to determine whether Ct values could be used to distinguish between culture-positive and culture-negative samples. Methods This was a retrospective analysis of Ct values from dermatophyte PCR results in cats with suspicious skin lesions or suspected exposure to dermatophytosis. Results One hundred and thirty-two samples were included. Using culture as the gold standard, 28 were true positives, 12 were false positives and 92 were true negatives. The area under the curve for the pretreatment time point was 96.8% (95% confidence interval [CI] 94.2-99.5) compared with 74.3% (95% CI 52.6-96.0) for pooled data during treatment. Before treatment, a Ct cut-off of <35.7 (approximate DNA count 300) provided a sensitivity of 92.3% and specificity of 95.2%. There was no reliable cut-off Ct value between culture-positive and culture-negative samples during treatment. Ct values prior to treatment differed significantly between the true-positive and false-positive groups ( P = 0.0056). There was a significant difference between the pretreatment and first and second negative culture time points ( P = 0.0002 and P <0.0001, respectively). However, there was substantial overlap between Ct values for true positives and true negatives, and for pre- and intra-treatment time points. Conclusions and relevance Ct values had limited usefulness for distinguishing between culture-positive and culture-negative cases when field study samples were analyzed. In addition, Ct values were less reliable than fungal culture for determining mycological cure.

  5. CT differentiation of 1-2-cm gallbladder polyps: benign vs malignant.

    PubMed

    Song, E Rang; Chung, Woo-Suk; Jang, Hye Young; Yoon, Minjae; Cha, Eun Jung

    2014-04-01

    To evaluate MDCT findings of 1-2-cm sized gallbladder (GB) polyps for differentiation between benign and malignant polyps. Institutional review board approval was obtained, and informed consent was waived. Portal venous phase CT scans of 1-2-cm sized GB polyps caused by various pathologic conditions were retrospectively reviewed by two blinded observers. Among the 36 patients identified, 21 had benign polyps with the remaining 15 having malignant polyps. Size, margin, and shape of GB polyps were evaluated. Attenuation values of the polyps, including mean attenuation, maximum attenuation, and standard deviation, were recorded. As determined by visual inspection, the degree of polyp enhancement was evaluated. Using these CT findings, each of the two radiologists assessed and recorded individual diagnostic confidence for differentiating benign versus malignant polyps on a 5-point scale. The diagnostic performance of CT was evaluated using a receiver operating characteristic curve analysis. There was no significant difference in size between benign and malignant GB polyps. Ill-defined margin and sessile morphology were significantly associated with malignant polyp. There was a significant difference in mean and maximum attenuation values between benign and malignant GB polyps. Mean standard deviation value of malignant polyps was significantly higher than that of benign polyps. All malignant polyps showed either hyperenhancement or marked hyperenhancement. A z value for the diagnosis of malignant GB polyps was 0.905. Margin, shape, and enhancement degree are helpful in differentiating between benign and malignant polyps of 1-2-cm sizes.

  6. Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve

    PubMed Central

    Tanaka, Haruki; Takahashi, Teruyuki; Ohashi, Norihiko; Tanaka, Koichi; Okada, Takenori; Kihara, Yasuki

    2017-01-01

    Abstract The aim of this study was to clarify the predictive value of fractional flow reserve (FFR) determined by myocardial perfusion imaging (MPI) using thallium (Tl)-201 IQ-SPECT without and with computed tomography-based attenuation correction (CT-AC) for patients with stable coronary artery disease (CAD). We assessed 212 angiographically identified diseased vessels using adenosine-stress Tl-201 MPI-IQ-SPECT/CT in 84 consecutive, prospectively identified patients with stable CAD. We compared the FFR in 136 of the 212 diseased vessels using visual semiquantitative interpretations of corresponding territories on MPI-IQ-SPECT images without and with CT-AC. FFR inversely correlated most accurately with regional summed difference scores (rSDS) in images without and with CT-AC (r = −0.584 and r = −0.568, respectively, both P < .001). Receiver-operating characteristics analyses using rSDS revealed an optimal FFR cut-off of <0.80 without and with CT-AC. Although the diagnostic accuracy of FFR <0.80 did not significantly differ, FFR ≥0.82 was significantly more accurate with, than without CT-AC. Regions with rSDS ≥2 without or with CT-AC predicted FFR <0.80, and those with rSDS ≤1 without and with CT-AC predicted FFR ≥0.81, with 73% and 83% sensitivity, 84% and 67% specificity, and 79% and 75% accuracy, respectively. Although limited by the sample size and the single-center design, these findings showed that the IQ-SPECT system can predict FFR at an optimal cut-off of <0.80, and we propose a novel application of CT-AC to MPI-IQ-SPECT for predicting clinically significant and insignificant FFR even in nonobese patients. PMID:29390486

  7. [Positron tomography with 18F-fluorodeoxyglucose in the preoperative evaluation of gall bladder lesions suspicious of malignancy. Diagnostic utility and clinical impact].

    PubMed

    Ramos-Font, C; Gómez Río, M; Rodríguez-Fernández, A; Sánchez Sánchez, R; Llamas Elvira, J M

    2011-01-01

    Gallbladder carcinoma is a neoplasm having a poor prognosis in which the role of the positron emission tomography with (18)F-fluordeoxyglucose as a diagnostic tool, although of possible usefulness, has not been well-defined. It is a prospective cohort of patients with radiologically malignant suspicious gallbladder lesions. A staging diagnostic presurgical FDG-PET study was carried out in each patient using both dedicated PET and multimodality PET-CT scanners. Diagnostic accuracy parameters were calculated from the results of PET imaging and were correlated with the condition and/or the clinical course of the patients. The clinical impact of its implementation in the diagnosis of gallbladder carcinoma was also analyzed. A total of 42 patients were recruited (22 malignant lesions, 20 benign). Overall diagnostic accuracy was 83.33% for the diagnosis of the primary lesion, 88.89% for the evaluation of lymph node involvement and 85.1% for the evaluation of metastatic disease. Mean SUVmax in malignant gallbladder lesions was 6.14±2.89. ROC curve showed a cut-off value of 3.65 in the SUVmax for malignancy. Accuracy of PET studies alone (n=21) was slightly lower than that of the PET/CT (n=21). FDG-PET changed the management of 14.8% of the population due to the identification of unsuspected metastatic disease. FDG-PET accurately diagnoses malignancy or benignity of suspicious gallbladder lesions, with the addition of its capacity to identify unsuspected metastatic disease. PET-CT improves the diagnostic accuracy of the procedure, due to the metabolic-structural complementarity of their information. The SUVmax has a complementary value added to the visual analysis. Copyright © 2010 Elsevier España, S.L. y SEMNIM. All rights reserved.

  8. Results of a prospective clinical study on the diagnostic performance of standard magnetic resonance imaging in comparison to a combination of 3T MRI and additional CT imaging in Kienböck's disease.

    PubMed

    Stahl, Stephane; Hentschel, Pascal; Ketelsen, Dominik; Grosse, Ulrich; Held, Manuel; Wahler, Theodora; Syha, Roland; Schaller, Hans-Eberhard; Nikolaou, Konstantin; Grözinger, Gerd

    2017-05-01

    This prospective clinical study examined standard wrist magnetic resonance imaging (MRI) examinations and the incremental value of computed tomography (CT) in the diagnosis of Kienböck's disease (KD) with regard to reliability and precision in the different diagnostic steps during diagnostic work-up. Sixty-four consecutive patients referred between January 2009 and January 2014 with positive initial suspicion of KD according to external standard wrist MRI were prospectively included (step one). Institutional review board approval was obtained. Clinical examination by two handsurgeons were followed by wrist radiographs (step two), ultrathin-section CT, and 3T contrast-enhanced MRI (step three). Final diagnosis was established in a consensus conference involving all examiners and all examinations results available from step three. In 12/64 patients, initial suspicion was discarded at step two and in 34/64 patients, the initial suspicion of KD was finally discarded at step three. The final external MRI positive predictive value was 47%. The most common differential diagnoses at step three were intraosseous cysts (n=15), lunate pseudarthrosis (n=13), and ulnar impaction syndrome (n=5). A correlation between radiograph-based diagnoses (step two) with final diagnosis (step three) showed that initial suspicion of stage I KD had the lowest sensitivity for correct diagnosis (2/11). Technical factors associated with a false positive external MRI KD diagnosis were not found. Standard wrist MRI should be complemented with thin-section CT, and interdisciplinary interpretation of images and clinical data, to increase diagnostic accuracy in patients with suspected KD. Copyright © 2017. Published by Elsevier B.V.

  9. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64.

    PubMed

    Miller, Julie M; Dewey, Marc; Vavere, Andrea L; Rochitte, Carlos E; Niinuma, Hiroyuki; Arbab-Zadeh, Armin; Paul, Narinder; Hoe, John; de Roos, Albert; Yoshioka, Kunihiro; Lemos, Pedro A; Bush, David E; Lardo, Albert C; Texter, John; Brinker, Jeffery; Cox, Christopher; Clouse, Melvin E; Lima, João A C

    2009-04-01

    Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective "CORE-64" trial ("Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors"). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.

  10. The value of multimodality imaging in the investigation of a PSA recurrence after radical prostatectomy in the Irish hospital setting.

    PubMed

    McLoughlin, L C; Inder, S; Moran, D; O'Rourke, C; Manecksha, R P; Lynch, T H

    2018-02-01

    The diagnostic evaluation of a PSA recurrence after RP in the Irish hospital setting involves multimodality imaging with MRI, CT, and bone scanning, despite the low diagnostic yield from imaging at low PSA levels. We aim to investigate the value of multimodality imaging in PC patients after RP with a PSA recurrence. Forty-eight patients with a PSA recurrence after RP who underwent multimodality imaging were evaluated. Demographic data, postoperative PSA levels, and imaging studies performed at those levels were evaluated. Eight (21%) MRIs, 6 (33%) CTs, and 4 (9%) bone scans had PCa-specific findings. Three (12%) patients had a positive MRI with a PSA <1.0 ng/ml, while 5 (56%) were positive at PSA ≥1.1 ng/ml (p = 0.05). Zero patient had a positive CT TAP at a PSA level <1.0 ng/ml, while 5 (56%) were positive at levels ≥1.1 ng/ml (p = 0.03). Zero patient had a positive bone at PSA levels <1.0 ng/ml, while 4 (27%) were positive at levels ≥1.1 ng/ml (p = 0.01). The diagnostic yield from multimodality imaging, and isotope bone scanning in particular, in PSA levels <1.0 ng/ml, is low. There is a statistically significant increase in the frequency of positive findings on CT and bone scanning at PSA levels ≥1.1 ng/ml. MRI alone is of investigative value at PSA <1.0 ng/ml. The indication for CT, MRI, or isotope bone scanning should be carefully correlated with the clinical question and how it will affect further management.

  11. Gold nanoshelled liquid perfluorocarbon nanocapsules for combined dual modal ultrasound/CT imaging and photothermal therapy of cancer.

    PubMed

    Ke, Hengte; Yue, Xiuli; Wang, Jinrui; Xing, Sen; Zhang, Qian; Dai, Zhifei; Tian, Jie; Wang, Shumin; Jin, Yushen

    2014-03-26

    The integration of multimodal contrast-enhanced diagnostic imaging and therapeutic capabilities could utilize imaging guided therapy to plan the treatment strategy based on the diagnostic results and to guide/monitor the therapeutic procedures. Herein, gold nanoshelled perfluorooctylbromide (PFOB) nanocapsules with PEGylation (PGsP NCs) are constructed by oil-in-water emulsion method to form polymeric PFOB nanocapsules, followed by the formation of PEGylated gold nanoshell on the surface. PGsP NCs could not only provide excellent contrast enhancement for dual modal ultrasound and CT imaging in vitro and in vivo, but also serve as efficient photoabsorbers for photothermal ablation of tumors on xenografted nude mouse model. To our best knowledge, this is the first report of gold nanoshell serving as both CT contrast agents and photoabsorbers for photothermal therapy. The novel multifunctional nanomedicine would be of great value to offer more comprehensive diagnostic information to guide more accurate and effective cancer therapy. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Is 3-Tesla Gd-EOB-DTPA-Enhanced MRI with Diffusion-Weighted Imaging Superior to 64-Slice Contrast-Enhanced CT for the Diagnosis of Hepatocellular Carcinoma?

    PubMed Central

    Maiwald, Bettina; Lobsien, Donald; Kahn, Thomas; Stumpp, Patrick

    2014-01-01

    Objectives To compare 64-slice contrast-enhanced computed tomography (CT) with 3-Tesla magnetic resonance imaging (MRI) using Gd-EOB-DTPA for the diagnosis of hepatocellular carcinoma (HCC) and evaluate the utility of diffusion-weighted imaging (DWI) in this setting. Methods 3-phase-liver-CT was performed in fifty patients (42 male, 8 female) with suspected or proven HCC. The patients were subjected to a 3-Tesla-MRI-examination with Gd-EOB-DTPA and diffusion weighted imaging (DWI) at b-values of 0, 50 and 400 s/mm2. The apparent diffusion coefficient (ADC)-value was determined for each lesion detected in DWI. The histopathological report after resection or biopsy of a lesion served as the gold standard, and a surrogate of follow-up or complementary imaging techniques in combination with clinical and paraclinical parameters was used in unresected lesions. Diagnostic accuracy, sensitivity, specificity, and positive and negative predictive values were evaluated for each technique. Results MRI detected slightly more lesions that were considered suspicious for HCC per patient compared to CT (2.7 versus 2.3, respectively). ADC-measurements in HCC showed notably heterogeneous values with a median of 1.2±0.5×10−3 mm2/s (range from 0.07±0.1 to 3.0±0.1×10−3 mm2/s). MRI showed similar diagnostic accuracy, sensitivity, and positive and negative predictive values compared to CT (AUC 0.837, sensitivity 92%, PPV 80% and NPV 90% for MRI vs. AUC 0.798, sensitivity 85%, PPV 79% and NPV 82% for CT; not significant). Specificity was 75% for both techniques. Conclusions Our study did not show a statistically significant difference in detection in detection of HCC between MRI and CT. Gd-EOB-DTPA-enhanced MRI tended to detect more lesions per patient compared to contrast-enhanced CT; therefore, we would recommend this modality as the first-choice imaging method for the detection of HCC and therapeutic decisions. However, contrast-enhanced CT was not inferior in our study, so that it can be a useful image modality for follow-up examinations. PMID:25375778

  13. Diagnostic Accuracy of 64Copper Prostate-specific Membrane Antigen Positron Emission Tomography/Computed Tomography for Primary Lymph Node Staging of Intermediate- to High-risk Prostate Cancer: Our Preliminary Experience.

    PubMed

    Cantiello, Francesco; Gangemi, Vincenzo; Cascini, Giuseppe Lucio; Calabria, Ferdinando; Moschini, Marco; Ferro, Matteo; Musi, Gennaro; Butticè, Salvatore; Salonia, Andrea; Briganti, Alberto; Damiano, Rocco

    2017-08-01

    To assess the diagnostic accuracy of 64 Copper prostate-specific membrane antigen ( 64 Cu-PSMA) positron emission tomography/computed tomography (PET/CT) in the primary lymph node (LN) staging of a selected cohort of intermediate- to high-risk prostate cancer (PCa) patients. An observational prospective study was performed in 23 patients with intermediate- to high-risk PCa, who underwent 64 Cu-PSMA PET/CT for local and lymph nodal staging before laparoscopic radical prostatectomy with an extended pelvic LN dissection. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for LN status of 64 Cu-PSMA PET/CT were calculated using the final pathological findings as reference. Furthermore, we evaluated the correlation of intraprostatic tumor extent and grading with 64 Cu-PSMA intraprostatic distribution. Pathological analysis of LN involvement in 413 LNs harvested from our study cohort identified a total of 22 LN metastases in 8 (5%) of the 23 (35%) PCa patients. Imaging-based LN staging in a per-patient analysis showed that 64 Cu-PSMA PET/CT was positive in 7 of 8 LN-positive patients (22%) with a sensitivity of 87.5%, specificity of 100%, PPV of 100%, and NPV of 93.7%, considering the maximum standardized uptake value (SUV max ) at 4 hours as our reference. Receiver operating characteristic curve was characterized by an area under the curve of 0.938. A significant positive association was observed between SUV max at 4 hours with Gleason score, index, and cumulative tumor volume. In our intermediate- to high-risk PCa patients study cohort, we showed the high diagnostic accuracy of 64 Cu-PSMA PET/CT for primary LN staging before radical prostatectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Correlation between tissue metabolism and cellularity assessed by standardized uptake value and apparent diffusion coefficient in peritoneal metastasis.

    PubMed

    Yu, Xue; Lee, Elaine Yuen Phin; Lai, Vincent; Chan, Queenie

    2014-07-01

    To evaluate the correlation between standardized uptake value (SUV) (tissue metabolism) and apparent diffusion coefficient (ADC) (water diffusivity) in peritoneal metastases. Patients with peritoneal dissemination detected on (18)F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) were prospectively recruited for MRI examinations with informed consent and the study was approved by the local Institutional Review Board. FDG-PET/CT, diffusion-weighted imaging (DWI), MRI, and DWI/MRI images were independently reviewed by two radiologists based on visual analysis. SUVmax/SUVmean and ADCmin/ADCmean were obtained manually by drawing ROIs over the peritoneal metastases on FDG-PET/CT and DWI, respectively. Diagnostic characteristics of each technique were evaluated. Pearson's coefficient and McNemar and Kappa tests were used for statistical analysis. Eight patients were recruited for this prospective study and 34 peritoneal metastases were evaluated. ADCmean was significantly and negatively correlated with SUVmax (r = -0.528, P = 0.001) and SUVmean (r = -0.548, P = 0.001). ADCmin had similar correlation with SUVmax (r = -0.508, P = 0.002) and SUVmean (r = -0.513, P = 0.002). DWI/MRI had high diagnostic performance (accuracy = 98%) comparable to FDG-PET/CT, in peritoneal metastasis detection. Kappa values were excellent for all techniques. There was a significant inverse correlation between SUV and ADC. © 2013 Wiley Periodicals, Inc.

  15. Diagnostic Accuracy of Computed Tomography Angiography as Compared to Conventional Angiography in Patients Undergoing Noncoronary Cardiac Surgery

    PubMed Central

    Joshi, Hasit; Shah, Ronak; Prajapati, Jayesh; Bhangdiya, Vipin; Shah, Jayal; Kandre, Yogini; Shah, Komal

    2016-01-01

    Objective: To compare the diagnostic accuracy of multi-slice computed tomography (MSCT) angiography with conventional angiography in patients undergoing major noncoronary cardiac surgeries. Materials and Methods: We studied fifty major noncoronary cardiac surgery patients scheduled for invasive coronary angiography, 29 (58%) female and 21 (42%) male. Inclusion criteria of the study were age of the patients ≥40 years, having low or intermediate probability of coronary artery disease (CAD), left ventricular ejection fraction (LVEF) >35%, and patient giving informed consent for undergoing MSCT and conventional coronary angiography. The patients with LVEF <35%, high pretest probability of CAD, and hemodynamically unstable were excluded from the study. Results: The diagnostic accuracy of CT coronary angiography was evaluated regarding true positive, true negative values. The overall sensitivity and specificity of CT angiography technique was 100% (95% confidence interval [CI]: 39.76%–100%) and 91.30% (95% CI: 79.21%–97.58%). The positive (50%; 95% CI: 15.70%–84.30%) and negative predictive values (100%; 95% CI: 91.59%–100%) of CT angiography were also fairly high in these patients. Conclusion: Our study suggests that this non-invasive technique may improve perioperative risk stratification in patients undegoing non-cardiac surgery. PMID:27867455

  16. What is the best way to diagnose and stage malignant pleural mesothelioma?

    PubMed

    Zahid, Imran; Sharif, Sumera; Routledge, Tom; Scarci, Marco

    2011-02-01

    A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was which diagnostic modality [computed tomography (CT), positron emission tomography (PET), combination PET/CT and magnetic resonance imaging (MRI)] provides the best diagnostic and staging information in patients with malignant pleural mesothelioma (MPM). Overall, 61 papers were found using the reported search, of which 14 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results are tabulated. We conclude that fluorodeoxyglucose (FDG)-PET is superior to MRI and CT but inferior to PET-CT, in terms of diagnostic specificity, sensitivity and staging of MPM. Four studies reported outcomes using FDG-PET to diagnose MPM. PET diagnosed MPM with high sensitivity (92%) and specificity (87.9%). Mean standardised uptake value (SUV) was higher in malignant than benign disease (4.91 vs. 1.41, P<0.0001). Lymph node metastases were detected with higher accuracy (80% vs. 66.7%) compared to extrathoracic disease. Three studies assessed the utility of PET-CT to diagnose MPM. Mean SUV was higher in malignant than benign disease (6.5 vs. 0.8, P<0.001). MPM was diagnosed with high sensitivity (88.2%), specificity (92.9%) and accuracy (88.9%). PET-CT had low sensitivity for stage N2 (38%) and T4 (67%) disease. CT-guided needle biopsy definitively diagnosed MPM after just one biopsy (100% vs. 9%) much more often than a 'blind' approach. CT had a lower success rate (92% vs. 100%) than thoracoscopic pleural biopsy but was equivalent to MRI in terms of detection of lymph node metastases (P=0.85) and visceral pleural tumour (P=0.64). CT had a lower specificity for stage II (77% vs. 100%, P<0.01) and stage III (75% vs. 100%, P<0.01) disease compared to PET-CT. Overall, the high specificity and sensitivity rates seen with open pleural biopsy make it a superior diagnostic modality to CT, MRI or PET for diagnosing patients with MPM.

  17. Optimizing the balance between radiation dose and image quality in pediatric head CT: findings before and after intensive radiologic staff training.

    PubMed

    Paolicchi, Fabio; Faggioni, Lorenzo; Bastiani, Luca; Molinaro, Sabrina; Puglioli, Michele; Caramella, Davide; Bartolozzi, Carlo

    2014-06-01

    The purpose of this study was to assess the radiation dose and image quality of pediatric head CT examinations before and after radiologic staff training. Outpatients 1 month to 14 years old underwent 215 unenhanced head CT examinations before and after intensive training of staff radiologists and technologists in optimization of CT technique. Patients were divided into three age groups (0-4, 5-9, and 10-14 years), and CT dose index, dose-length product, tube voltage, and tube current-rotation time product values before and after training were retrieved from the hospital PACS. Gray matter conspicuity and contrast-to-noise ratio before and after training were calculated, and subjective image quality in terms of artifacts, gray-white matter differentiation, noise, visualization of posterior fossa structures, and need for repeat CT examination was visually evaluated by three neuroradiologists. The median CT dose index and dose-length product values were significantly lower after than before training in all age groups (27 mGy and 338 mGy ∙ cm vs 107 mGy and 1444 mGy ∙ cm in the 0- to 4-year-old group, 41 mGy and 483 mGy ∙ cm vs 68 mGy and 976 mGy ∙ cm in the 5- to 9-year-old group, and 51 mGy and 679 mGy ∙ cm vs 107 mGy and 1480 mGy ∙ cm in the 10- to 14-year-old group; p < 0.001). The tube voltage and tube current-time values after training were significantly lower than the levels before training (p < 0.001). Subjective posttraining image quality was not inferior to pretraining levels for any item except noise (p < 0.05), which, however, was never diagnostically unacceptable. Radiologic staff training can be effective in reducing radiation dose while preserving diagnostic image quality in pediatric head CT examinations.

  18. Diagnostic value of 18F-fluordesoxyglucose positron emission tomography for patients with brain metastasis from unknown primary site.

    PubMed

    Wolpert, Fabian; Weller, Michael; Berghoff, Anna Sophie; Rushing, Elisabeth; Füreder, Lisa Michaela; Petyt, Gregory; Leske, Henning; Andratschke, Nicolaus; Regli, Luca; Neidert, Marian Christoph; Stupp, Roger; Stahel, Rolf; Dummer, Reinhard; Frauenfelder, Thomas; Roth, Patrick; Reyns, Nicolas; Kaufmann, Philipp Antonio; Preusser, Matthias; Le Rhun, Emilie

    2018-04-17

    In 30% of patients with brain metastasis (BM), neurological symptoms are the first clinical manifestation of systemic malignancy, referred to as BM from cancer of unknown primary site (BM-CUPS). Here, we define the diagnostic value of 18 F-fluordesoxyglucose positron emission tomography (FDG-PET/CT) in the workup of BM-CUPS. We screened 565 patients operated for BM at the University Hospital Zurich and identified 64 patients with BM-CUPS with data on both FDG-PET/CT and contrast-enhanced chest/abdomen computed tomography (CT) available at BM diagnosis. A cohort of 125 patients with BM-CUPS from Lille and Vienna was used for validation. FDG-PET/CT was not superior to chest/abdomen CT in localising the primary lesion in the discovery cohort, presumably because most primary tumours were lung cancers. However, FDG-PET/CT identified additional lesions suspicious of extracranial metastases in 27 of 64 patients (42%). The inclusion of FDG-PET/CT findings shifted the graded prognostic assessment (GPA) score from 3 with CT alone to 2.5 for PET/CT (p = 3.8 × 10 -5 , Wilcoxon's test), resulting in a predicted survival of 5.3 versus 3.8 months (p = 6.1 × 10 -5 ; Wilcoxon's test). All observations were confirmed in the validation cohort. Lung cancers are the most common primary tumour in BM-CUPS; accordingly, CT alone shows similar overall sensitivity for detecting the primary tumour as FDG-PET/CT. Yet, FDG-PET/CT improves the accuracy of staging by detecting more metastases, reflected by decreased GPA scores and decreased predicted survival. Therefore, randomised trials on patients with BM should standardise methods of staging, notably when stratifying for GPA. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Role of multidetector computed tomography in evaluating incidentally detected breast lesions.

    PubMed

    Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile

    2015-01-01

    Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.

  20. A single institution study of radiation dose received from CT imaging: A comparison to Malaysian NDRL

    NASA Astrophysics Data System (ADS)

    Osman, N. D.; Shamsuri, S. B. M.; Tan, Y. W.; Razali, M. A. S. M.; Isa, S. M.

    2017-05-01

    Advancement of CT technology has led to an increase in CT scanning as it improves the diagnosis. However, it is important to assess health risk of patients associated with ionising radiation received from CT. This study evaluated current dose distributions at Advanced Medical and Dental Institute (AMDI), Malaysia and was used to establish Local Diagnostic Reference Level (LDRL). Dose indicators such as CT Dose Index (CTDIvol and CTDIw) and Dose-Length Product (DLP) were gathered for all routine CT examinations performed at the Imaging Unit, AMDI from January 2015 to June 2016. The first and third quartile values for each dose indicator were determined. A total of 364 CT studies were performed during that period with the highest number of cases being Thorax-Abdomen-Pelvis (TAP) study (57% of total study). The CTDIw ranged between 2.0 mGy to 23.4 mGy per procedure. DLP values were ranged between 94 mGy.cm to 1687 mGy.cm. The local dose data was compared with the national DRL to monitor the current CT practice at AMDI and LDRL will be established from the calculated third quartile values of dose distribution. From the results, some of the local dose values exceeded the Malaysian and further evaluation is important to ensure the dose optimisation for patients.

  1. Diagnostic value of combining ¹¹C-choline and ¹⁸F-FDG PET/CT in hepatocellular carcinoma.

    PubMed

    Castilla-Lièvre, Maria-Angéla; Franco, Dominique; Gervais, Philippe; Kuhnast, Bertrand; Agostini, Hélène; Marthey, Lysiane; Désarnaud, Serge; Helal, Badia-Ourkia

    2016-05-01

    In this prospective study, our goal was to emphasize the diagnostic value of combining (11)C-choline and (18)F-FDG PET/CT for hepatocellular carcinoma (HCC) in patients with chronic liver disease. Thirty-three consecutive patients were enrolled. All patients were suspected to have HCC based on CT and/or MRI imaging. A final diagnosis was obtained by histopathological examination or by imaging alone according to American Association for the Study of Liver Disease criteria. All patients underwent PET/CT with both tracers within a median of 5 days. All lesions showing higher tracer uptake than normal liver were considered positive for HCC. We examined how tracer uptake was related to biological (serum α-fetoprotein levels) and pathological (differentiation status, peritumoral capsule and vascular invasion) prognostic markers of HCC, as well as clinical observations at 6 months (recurrence and death). Twenty-eight HCC, four cholangiocarcinomas and one adenoma were diagnosed. In the HCC patients, the sensitivity of (11)C-choline, (18)F-FDG and combined (11)C-choline and (18)F-FDG PET/CT for the detection of HCC was 75 %, 36 % and 93 %, respectively. Serum α-fetoprotein levels >200 ng/ml were more frequent among patients with (18)F-FDG-positive lesions than those with (18)F-FDG-negative lesions (p < 0.05). Early recurrence (n=2) or early death (n=5) occurred more frequently in patients with (18)F-FDG-positive lesions than in those with (18)F-FDG-negative lesions (p < 0.05). The combined use of (11)C-choline and (18)F-FDG PET/CT detected HCC with high sensitivity. This approach appears to be of potential prognostic value and may facilitate the selection of patients for surgical resection or liver transplantation.

  2. 18F-FDG PET/CT oncologic imaging at extended injection-to-scan acquisition time intervals derived from a single-institution 18F-FDG-directed surgery experience: feasibility and quantification of 18F-FDG accumulation within 18F-FDG-avid lesions and background tissues

    PubMed Central

    2014-01-01

    Background 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) is a well-established imaging modality for a wide variety of solid malignancies. Currently, only limited data exists regarding the utility of PET/CT imaging at very extended injection-to-scan acquisition times. The current retrospective data analysis assessed the feasibility and quantification of diagnostic 18F-FDG PET/CT oncologic imaging at extended injection-to-scan acquisition time intervals. Methods 18F-FDG-avid lesions (not surgically manipulated or altered during 18F-FDG-directed surgery, and visualized both on preoperative and postoperative 18F-FDG PET/CT imaging) and corresponding background tissues were assessed for 18F-FDG accumulation on same-day preoperative and postoperative 18F-FDG PET/CT imaging. Multiple patient variables and 18F-FDG-avid lesion variables were examined. Results For the 32 18F-FDG-avid lesions making up the final 18F-FDG-avid lesion data set (from among 7 patients), the mean injection-to-scan times of the preoperative and postoperative 18F-FDG PET/CT scans were 73 (±3, 70-78) and 530 (±79, 413-739) minutes, respectively (P < 0.001). The preoperative and postoperative mean 18F-FDG-avid lesion SUVmax values were 7.7 (±4.0, 3.6-19.5) and 11.3 (±6.0, 4.1-29.2), respectively (P < 0.001). The preoperative and postoperative mean background SUVmax values were 2.3 (±0.6, 1.0-3.2) and 2.1 (±0.6, 1.0-3.3), respectively (P = 0.017). The preoperative and postoperative mean lesion-to-background SUVmax ratios were 3.7 (±2.3, 1.5-9.8) and 5.8 (±3.6, 1.6-16.2), respectively, (P < 0.001). Conclusions 18F-FDG PET/CT oncologic imaging can be successfully performed at extended injection-to-scan acquisition time intervals of up to approximately 5 half-lives for 18F-FDG while maintaining good/adequate diagnostic image quality. The resultant increase in the 18F-FDG-avid lesion SUVmax values, decreased background SUVmax values, and increased lesion-to-background SUVmax ratios seen from preoperative to postoperative 18F-FDG PET/CT imaging have great potential for allowing for the integrated, real-time use of 18F-FDG PET/CT imaging in conjunction with 18F-FDG-directed interventional radiology biopsy and ablation procedures and 18F-FDG-directed surgical procedures, as well as have far-reaching impact on potentially re-shaping future thinking regarding the “most optimal” injection-to-scan acquisition time interval for all routine diagnostic 18F-FDG PET/CT oncologic imaging. PMID:24942656

  3. Diagnostic importance of 18F-FDG PET/CT parameters and total lesion glycolysis in differentiating between benign and malignant adrenal lesions.

    PubMed

    Ciftci, Esra; Turgut, Bulent; Cakmakcilar, Ali; Erturk, Seyit A

    2017-09-01

    Benign adrenal lesions are prevalent in oncologic imaging and make metastatic disease diagnoses difficult. This study evaluates the diagnostic importance of metabolic, volumetric, and metabolovolumetric parameters measured by fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT in differentiating between benign and malignant adrenal lesions in cancer patients. In this retrospective study, we evaluated F-FDG PET/CT parameters of adrenal lesions of follow-up cancer patients referred to our clinic between January 2012 and November 2016. The diagnosis of adrenal malignant lesions was made on the basis of interval growth or reduction after chemotherapy. Patient demographics, analysis of metabolic parameters such as maximum standard uptake value (SUVmax), tumor SUVmax/liver SUVmean ratio (T/LR), morphologic parameters such as size, Hounsfield Units, and computed tomography (CT) volume, and metabolovolumetric parameters such as metabolic tumor volume and total lesion glycolysis (TLG) of adrenal lesions were calculated. PET/CT parameters were assessed using the Mann-Whitney U-test and receiving operating characteristic analysis. In total, 186 adrenal lesions in 163 cancer patients (108 men/54 women; mean±SD age: 64±10.9 years) were subjected to F-FDG PET/CT for tumor evaluation. SUVmax values (mean±SD) were 2.8±0.8 and 10.6±6; TLG were 10.8±9.2 and 124.4±347.9; and T/LR were 1±0.3 and 4.1±2.6 in benign and malignant adrenal lesions, respectively. On the basis of the area under the curve, adrenal lesion SUVmax and T/LR had similar highest diagnostic performance for predicting malignant lesions (area under the curve: 0.993 and 0.991, respectively, P<0.001). Multivariate logistic regression analysis showed that T/LR, adrenal lesion SUVmax, and Hounsfield Units were independent predictive factors for malignancy rather than TLG. Irrespective of whether TLG was statistically highly significant for differentiating benign from malignant adrenal lesions, it did not reach the expected performance with a low negative predictive value. This may be because of the malignant but small and benign but large lesions on metabolovolumetric calculation.

  4. Systematic review on the value of CT scanning in the diagnosis of anastomotic leakage after colorectal surgery.

    PubMed

    Kornmann, Verena N N; Treskes, Nikki; Hoonhout, Lilian H F; Bollen, Thomas L; van Ramshorst, Bert; Boerma, Djamila

    2013-04-01

    Timely diagnosis of anastomotic leakage after colorectal surgery and adequate treatment is important to reduce morbidity and mortality. Abdominal computed tomography (CT) scanning is the diagnostic tool of preference, but its value may be questionable in the early postoperative period. The accuracy of CT scanning for the detection of anastomotic leakage and its role in timing of intervention was evaluated. A systematic literature search was performed. Relevant publications were identified from four electronic databases between 1990 and 2011. Inclusion criteria were human studies, studies published in English or Dutch, colorectal surgery with primary anastomosis, and abdominal CT scan with reported outcome for the detection of anastomotic leakage. Exclusion criteria were cohort of fewer than five patients, other gastrointestinal surgery, no anastomosis, and radiological imaging other than CT. Eight studies, including 221 abdominal CT scans, fulfilled the inclusion criteria. Overall, the methodological quality of the studies was poor. The overall sensitivity of CT scanning to diagnose leakage was 0.68 (95 % confidence interval 0.59-0.75) for colonic resection. Data on the sequelae of false-negative CT scanning was not available. There is limited good-quality evidence to determine the value of CT scans in the detection of anastomotic leakage. To prevent delay in diagnosis and appropriate treatment of anastomotic leakage, the relatively low sensitivity of CT scanning must be taken into account.

  5. 18F-Fluorocholine PET/CT Complementing the Role of Dynamic Contrast-Enhanced MRI for Providing Comprehensive Diagnostic Workup in Prostate Cancer Patients With Suspected Relapse Following Radical Prostatectomy.

    PubMed

    Vadi, Shelvin Kumar; Singh, Baljinder; Basher, Rajender K; Watts, Ankit; Sood, Ashwani K; Lal, Anupam; Kakkar, Nandita; Singh, S K

    2017-08-01

    The aim of this study was to compare the diagnostic performance of F-fluorocholine (FCH) PET/CT and dynamic contrast-enhanced MRI (DCE-MRI) of pelvis in restaging prostate cancer (PC) patients with biochemical recurrence (BCR) following radical prostatectomy (RP). Twenty PC patients who had undergone RP and had BCR were recruited in this study. All the patients underwent whole-body FCH PET/CT and DCE-MRI of the pelvis. An overall pattern of recurrent disease was analyzed, and diagnostic accuracy for the detection of pelvic disease recurrence by the 2 modalities was evaluated by taking histopathologic analysis as the criterion standard. The whole-body FCH PET/CT images were also analyzed separately for the presence of any extra lesion(s). The initial mean Gleason score was 6.3 ± 1.53 (range, 4-9). The mean prostate-specific antigen levels at the time of relapse were 1.9 ± 2.87 ng/mL (range, 0.24-13.2 ng/mL). MRI findings were positive for primary tumor recurrence in the prostate bed in 6 patients (6/20 [30.0%]), pelvic lymph node metastases in 4 patients (4/20 [20.0%]), and for pelvic skeletal metastases in 2 patients (2/20 [10.0%]), respectively. On the other hand, FCH PET/CT results were positive in the corresponding sites in 7 (7/20 [35.0%]), 9 (9/20 [45.0%]), and 2 patients (2/20 [10.0%]), respectively. F-fluorocholine PET/CT and MRI showed comparable results in terms of sensitivity, specificity, and positive and negative predictive values for PC characterization. The whole-body FCH PET/CT was found to be useful in identifying unknown distant metastases in a significant proportion of patients. The correlative whole-body FCH PET/CT and pelvic DCE-MRI offer a complementary and comprehensive diagnostic workup for better management of PC patients with BCR following RP.

  6. Prediction of calcium level in melamine-related urinary calculi with helical CT: diagnostic performance evaluation and clinical significance.

    PubMed

    Yuan, Li; Xiaorui, Ru; Gang, Huang; Xinsheng, Xi; Xiaogang, Huang; Li, Dong; Yirong, Chen

    2012-06-01

    The aim of the study was to investigate the relationship between CT-attenuation and stone calcium level in melamine-related urinary calculi (MRUC). A total of 25 MRUC with known composition and calcium level were included (11 uric acid stones, 2 calcium oxalate stones and 12 mixture stones of uric acid and calcium oxalate). Of all, 18 renal stones accepted alkalization therapy except for 5 lower urinary tract stones and 2 stones of unknown position. With well-matched composition, 61 adult urinary stones were included as controls. Every stone was scanned by helical CT (80 kV/120 kV, 300 mA, pitch 0.625 mm) and the highest CT-attenuation value measured. CT-attenuation values of MRUC increased gradually from uric acid stones, mixture stones to calcium oxalate stones, but were always lower than the values of controls. Furthermore, a strong positive correlation was found between stone CT-attenuation value and stone calcium level (n = 25, r (80kV) = 0.883, p = 0.000; r (120kV) = 0.855, p = 0.000). Compared with alkalization-therapy-alone group, stone CT-attenuation values and stone calcium level in the comprehensive-therapy group were significantly greater (CT(80kV) 1,057 ± 639 vs. 172 ± 61 HU, p = 0.001; CT(120kV) 783 ± 476 vs. 162 ± 60 HU, p = 0.001; Ca 19.83 ± 7.48% vs. 1.30 ± 1.51%, p = 0.000). Fisher's exact test suggested that the stones with higher CT-attenuation values tended to resist alkalization when 400 HU served as the cutoff value (P (80kV) = 0.002, P (120kV) = 0.000). In conclusion, the study was the first to illustrate that the CT-attenuation value could reflect calcium level in MRUC and found that stones with higher CT-attenuation value were not amenable to alkalization because they probably contained greater calcium. For those patients, we believe that comprehensive therapy will be the best choice.

  7. The Added Diagnostic Value of 18F-Fluorodihydroxyphenylalanine PET/CT in the Preoperative Work-Up of Small Bowel Neuroendocrine Tumors.

    PubMed

    Addeo, Pietro; Poncet, Gilles; Goichot, Bernard; Leclerc, Loic; Brigand, Cécile; Mutter, Didier; Romain, Benoit; Namer, Izzie-Jacques; Bachellier, Philippe; Imperiale, Alessio

    2018-04-01

    The precise localization of the primary tumor and/or the identification of multiple primary tumors improves the preoperative work-up in patients with small bowel (SB) neuroendocrine tumor (NET). The present study assesses the diagnostic value of 18 F-fluorodihydroxyphenylalanine ( 18 F-FDOPA) positron emission tomography/computed tomography (PET/CT) during the preoperative wok-up of SB NETs. Between January 2010 and June 2017, all consecutive patients with SB NETs undergoing preoperative 18 F-FDOPA PET/CT and successive resection were analyzed. Preoperative work-up included computed tomography (CT), somatostatin receptor scintigraphy (SRS), and 18 F-FDOPA PET/CT. Sensitivity and accuracy ratio for primary and multiple tumor detection were compared with data from surgery and pathology. There were 17 consecutive patients with SB NETs undergoing surgery. Nine patients (53%) had multiple tumors, 15 (88%) metastatic lymph nodes, 3 (18%) peritoneal carcinomatosis, and 9 patients (53%) liver metastases. A total of 70 SB NETs were found by pathology. Surgery identified the primary in 17/17 (100%) patients and recognized seven of 9 patients (78%) with multiple synchronous SB. Preoperatively, 18 F-FDOPA PET/CT displayed a statistically significant higher sensitivity for primary tumor localization (100 vs. 23.5 vs. 29.5%) and multiple tumor detection (78 vs. 22 vs. 11%) over SRS and CT. Compared with pathology, 18 F-FDOPA PET/CT displayed the highest accuracy ratio for number of tumor detected over CT and SRS (2.0 ± 2.2 vs. 0.4 ± 0.7 vs. 0.6 ± 1.5, p = 0.0003). 18 F-FDOPA PET/CT significantly increased the sensitivity and accuracy for primary and multiple SB NET identification. 18 F-FDOPA PET/CT should be included systematically in the preoperative work-up of SB NET.

  8. Retrospective evaluation of ultrasound-indeterminate renal multilocular cystic masses by using neutrophil-lymphocyte ratio and computed tomography.

    PubMed

    Wang, Hanfeng; Gu, Liangyou; Jia, Rui; Zeng, Jing; Liu, Xiaoxia; Zhang, Dawei; Wu, Yongjie; Luo, Guangda; Zhang, Xu

    2017-01-01

    To evaluate the clinical usefulness of neutrophil-lymphocyte ratio (NLR) in differentiating the ultrasound-indeterminate renal multilocular cystic masses (RMCM) in comparison with computed tomography (CT) and whether NLR has additional benefits to CT on sensitivity of detecting the malignant. Overall, 93 patients who underwent normal ultrasound with a conclusion of indeterminate RMCM were examined by NLR and CT within 30 days before surgery or follow-up from March to September 2014 at PLA General Hospital and enrolled in this retrospective study. Logistic regression model was performed to find independent predictors for differentiating true nature of RMCM; differences in the validity parameters and diagnostic power of CT, NLR, and their combination were compared using McNemar tests and AUC model, respectively. The final diagnoses of the 93 patients consisted of 36 patients with benign complex cysts, 16 with multilocular cystic renal cell carcinoma, 9 with multilocular cystic nephroma, and 32 with clear cell renal cell carcinoma. Higher NLR were strongly associated with malignant masses. Multivariate logistic regression analysis revealed that NLR could be an independent predictor for differentiating true nature of these masses (OR = 3.617; 95% CI: 1.219-10.727; P = 0.020). For detecting the malignant masses, the sensitivity, specificity, and accuracy were 71.9%, 80.6%, and 75.3% for CT and 57.9%, 88.9%, and 69.9% for NLR under cutoff value of 2.31, respectively, whereas those of CT+NLR were 89.5%, 69.4%, and 81.7%. No significant difference was found between CT and NLR in sensitivity (P = 0.185), specificity (P = 0.549), and accuracy (P = 0.428). But the sensitivity of CT+NLR was significantly higher than those of CT (P = 0.002) and NLR (P<0.001), respectively; AUC model analysis indicated that CT+NLR got the largest area of 0.795 (P<0.001, 95% CI: 0.693-0.896) in comparison with those of CT (area = 0.795, P<0.001, 95% CI: 0.661-0.864) and NLR (area = 0.734, P<0.001, 95% CI: 0.631-0.836). Given that NLR, under cutoff value of 2.31, had no diagnostic difference with CT in evaluating the ultrasound-indeterminate RMCM. However, combination of CT and NLR could increase the sensitivity of detecting malignant masses and acquire the best diagnostic power. Prospectively larger cohort and multicenter studies are still necessary. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Diagnostic value of using 18F-FDG PET and PET/CT in immunocompetent patients with primary central nervous system lymphoma: A systematic review and meta-analysis.

    PubMed

    Zou, Yaru; Tong, Jianjing; Leng, Haiyan; Jiang, Jingwei; Pan, Meng; Chen, Zi

    2017-06-20

    18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) and PET/CT have become two of the most powerful tools for malignant lymphoma exploration, but their diagnostic role in primary central nervous system lymphoma (PCNSL) is still disputed. The purpose of our study is to identify the usefulness of 18F-FDG PET and PET/CT for detecting PCNSL. A total of 129 patients, obtained from eight eligible studies, were included for this systematic review and meta-analysis. The performance of 18F-FDG PET and PET/CT for diagnosing PCNSL were as follows: the pooled sensitivity was 0.88 (95% CI: 0.80-0.94), specificity was 0.86 (95% CI: 0.73-0.94), positive likelihood ratio (PLR) was 3.99 (95% CI: 2.31-6.90), negative likelihood ratio (NLR) was 0.11 (95% CI: 0.04-0.32), and diagnostic odds ratio (DOR) was 33.40 (95% CI: 10.40-107.3). In addition, the area under the curve (AUC) and Q index were 0.9192 and 0.8525, respectively. PubMed/MEDLINE, Embase and Cochrane Library were systematically searched for potential publications (last updated on July 16th, 2016). Reference lists of included articles were also checked. Original articles that reported data on patients who were suspected of having PCNSL were considered suitable for inclusion. The sensitivities and specificities of 18F-FDG PET and PET/CT in each study were evaluated. The Stata software and Meta-Disc software were employed in the process of data analysis. 18F-FDG PET and PET/CT showed considerable accuracy in identifying PCNSL in immunocompetent patients and could be a valuable radiological diagnostic tool for PCNSL.

  10. SU-F-BRF-10: Deformable MRI to CT Validation Employing Same Day Planning MRI for Surrogate Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padgett, K; Stoyanova, R; Johnson, P

    Purpose: To compare rigid and deformable registrations of the prostate in the multi-modality setting (diagnostic-MRI to planning-CT) by utilizing a planning-MRI as a surrogate. The surrogate allows for the direct quantitative analysis which can be difficult in the multi-modality domain where intensity mapping differs. Methods: For ten subjects, T2 fast-spin-echo images were acquired at two different time points, the first several weeks prior to planning (diagnostic-MRI) and the second on the same day in which the planning CT was collected (planning-MRI). Significant effort in patient positioning and bowel/bladder preparation was undertaken to minimize distortion of the prostate in all datasets.more » The diagnostic-MRI was deformed to the planning-CT utilizing a commercially available deformable registration algorithm synthesized from local registrations. The deformed MRI was then rigidly aligned to the planning MRI which was used as the surrogate for the planning-CT. Agreement between the two MRI datasets was scored using intensity based metrics including Pearson correlation and normalized mutual information, NMI. A local analysis was performed by looking only within the prostate, proximal seminal vesicles, penile bulb and combined areas. A similar method was used to assess a rigid registration between the diagnostic-MRI and planning-CT. Results: Utilizing the NMI, the deformable registrations were superior to the rigid registrations in 9 of 10 cases demonstrating a 15.94% improvement (p-value < 0.001) within the combined area. The Pearson correlation showed similar results with the deformable registration superior in the same number of cases and demonstrating a 6.97% improvement (p-value <0.011). Conclusion: Validating deformable multi-modality registrations using spatial intensity based metrics is difficult due to the inherent differences in intensity mapping. This population provides an ideal testing ground for MRI to CT deformable registrations by obviating the need for multi-modality comparisons which are inherently more challenging. Deformable registrations generated in this work significantly outperformed rigid alignments. Research reported in this abstract was supported by the NIH National Cancer Institute R21CA153826 “MRI-Guided Radiotherapy and Biomarkers for Prostate Cancer” and Bankhead-Coley Cancer Research Program 10BT-03 “MRI-Guided Radiotherapy and Biomarkers for Prostate Cancer”.« less

  11. The diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients: A systematic review and diagnostic meta-analysis.

    PubMed

    Yoon, Hee Mang; Suh, Chong Hyun; Cho, Young Ah; Kim, Jeong Rye; Lee, Jin Seong; Jung, Ah Young; Kim, Jung Heon; Lee, Jeong-Yong; Kim, So Yeon

    2018-06-01

    To evaluate the diagnostic performance of reduced-dose CT for suspected appendicitis. A systematic search of the MEDLINE and EMBASE databases was carried out through to 10 January 2017. Studies evaluating the diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients were selected. Pooled summary estimates of sensitivity and specificity were calculated using hierarchical logistic regression modelling. Meta-regression was performed. Fourteen original articles with a total of 3,262 patients were included. For all studies using reduced-dose CT, the summary sensitivity was 96 % (95 % CI 93-98) with a summary specificity of 94 % (95 % CI 92-95). For the 11 studies providing a head-to-head comparison between reduced-dose CT and standard-dose CT, reduced-dose CT demonstrated a comparable summary sensitivity of 96 % (95 % CI 91-98) and specificity of 94 % (95 % CI 93-96) without any significant differences (p=.41). In meta-regression, there were no significant factors affecting the heterogeneity. The median effective radiation dose of the reduced-dose CT was 1.8 mSv (1.46-4.16 mSv), which was a 78 % reduction in effective radiation dose compared to the standard-dose CT. Reduced-dose CT shows excellent diagnostic performance for suspected appendicitis. • Reduced-dose CT shows excellent diagnostic performance for evaluating suspected appendicitis. • Reduced-dose CT has a comparable diagnostic performance to standard-dose CT. • Median effective radiation dose of reduced-dose CT was 1.8 mSv (1.46-4.16). • Reduced-dose CT achieved a 78 % dose reduction compared to standard-dose CT.

  12. Histopathologic diversity of gastric cancers: Relationship between enhancement pattern on dynamic contrast-enhanced CT and histological type.

    PubMed

    Tsurumaru, Daisuke; Miyasaka, Mitsutoshi; Muraki, Toshio; Nishie, Akihiro; Asayama, Yoshiki; Oki, Eiji; Oda, Yoshinao; Honda, Hiroshi

    2017-12-01

    To evaluate the diagnostic value of contrast-enhanced computed tomography gastrography (CE-CTG) to predict the histological type of gastric cancer. We analyzed 47 consecutive patients with resectable advanced gastric cancer preoperatively evaluated by multiphasic dynamic contrast-enhanced CT. Two radiologists independently reviewed the CT images and they determined the peak enhancement phase, and then measured the CT attenuation value of the gastric lesion for each phase. The histological types of gastric cancers were assigned to three groups as differentiated-type, undifferentiated-type, and mixed-type. We compared the peak enhancement phase of the three types and compared the CT attenuation values in each phase. The peak enhancement was significantly different between the three types of gastric cancers for both readers (reader 1, p=0.001; reader 2, p=0.009); most of the undifferentiated types had peak enhancement in the delayed phase. The CT attenuation values of undifferentiated type were significantly higher than those of differentiated or mixed type in the delayed phase according to both readers (reader 1, p=0.002; reader 2, p=0.004). CE-CTG could provide helpful information in diagnosing the histological type of gastric cancers preoperatively. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Identification of Nasal Bone Fractures on Conventional Radiography and Facial CT: Comparison of the Diagnostic Accuracy in Different Imaging Modalities and Analysis of Interobserver Reliability

    PubMed Central

    Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin

    2013-01-01

    Background There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. Objectives To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. Patients and Methods A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Results Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. Conclusion For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee. PMID:24348599

  14. A prospective evaluation of conventional cystography for detection of urine leakage at the vesicourethral anastomosis site after radical prostatectomy based on computed tomography.

    PubMed

    Han, K S; Choi, H J; Jung, D C; Park, S; Cho, K S; Joung, J Y; Seo, H K; Chung, J; Lee, K H

    2011-03-01

    To evaluate the diagnostic accuracy of conventional cystography for the detection of urine leakage at the vesicourethral anastomosis (VUA) site after radical prostatectomy based on computed tomography (CT) cystography. Patients who underwent radical prostatectomies at a single tertiary cancer centre were prospectively enrolled. Conventional cystography was routinely performed on postoperative day 7. Non-enhanced pelvic CT images were obtained after retrograde instillation of the same contrast material for a reference standard of urine leakage at the VUA site. Urine leakage was classified as follows: none; a plication abnormality; mild; moderate; and excessive. One hundred and twenty consecutive patients were enrolled. Conventional cystography detected 14 urine leakages, but CT cystography detected 40 urine leakages, which consisted of 28 mild and 12 moderate urine leakages. When using CT cystography as the standard measurement, conventional cystography showed a diagnostic accuracy of 17.8% (5/28) for mild urine leakage and 75% (9/12) for moderate leakage. Of nine patients diagnosed with mild leakage on conventional cystography, four (44.4%) had complicated moderate urine leakages based on CT cystography, requiring prolonged catheterization. The sensitivity, specificity, positive and negative predictive values, and accuracy of conventional cystography were 35, 100, 100, 75.4, and 78.3%, respectively. Conventional cystography is less accurate than CT cystography for diagnosing urine leakage at the VUA site after a radical prostatectomy. The present results suggest that CT cystography is a good choice for diagnostic imaging of urine leakage after radical prostatectomy. Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. Diagnostic value of computed tomography in dogs with chronic nasal disease.

    PubMed

    Saunders, Jimmy H; van Bree, Henri; Gielen, Ingrid; de Rooster, Hilde

    2003-01-01

    Computed tomographic (CT) studies of 80 dogs with chronic nasal disease (nasal neoplasia (n = 19), nasal aspergillosis (n = 46), nonspecific rhinitis (n = 11), and foreign body rhinitis (n = 4)) were reviewed retrospectively by two independent observers. Each observer filled out a custom-designed list to record his or her interpretation of the CT signs and selected a diagnosis. Accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for the diagnosis of each disease. The agreement between observers was evaluated. The CT signs corresponded to those previously described in the literature. CT had an accuracy greater than 90% for each observer in all disease processes. The sensitivity, specificity, PPV, and NPV were greater than 80% in all dogs with the exception of the PPV of foreign body rhinitis (80% for observer A and 44% for observer B). There was a substantial, to almost perfect, agreement between the two observers regarding the CT signs and diagnosis. This study indicates a high accuracy of CT for diagnosis of dogs with chronic nasal disease. The differentiation between nasal aspergillosis restricted to the nasal passages and foreign body rhinitis may be difficult when the foreign body is not visible.

  16. Lymph node detection in IASLC-defined zones on PET/CT images

    NASA Astrophysics Data System (ADS)

    Song, Yihua; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.

    2016-03-01

    Lymph node detection is challenging due to the low contrast between lymph nodes as well as surrounding soft tissues and the variation in nodal size and shape. In this paper, we propose several novel ideas which are combined into a system to operate on positron emission tomography/ computed tomography (PET/CT) images to detect abnormal thoracic nodes. First, our previous Automatic Anatomy Recognition (AAR) approach is modified where lymph node zones predominantly following International Association for the Study of Lung Cancer (IASLC) specifications are modeled as objects arranged in a hierarchy along with key anatomic anchor objects. This fuzzy anatomy model built from diagnostic CT images is then deployed on PET/CT images for automatically recognizing the zones. A novel globular filter (g-filter) to detect blob-like objects over a specified range of sizes is designed to detect the most likely locations and sizes of diseased nodes. Abnormal nodes within each automatically localized zone are subsequently detected via combined use of different items of information at various scales: lymph node zone model poses found at recognition indicating the geographic layout at the global level of node clusters, g-filter response which hones in on and carefully selects node-like globular objects at the node level, and CT and PET gray value but within only the most plausible nodal regions for node presence at the voxel level. The models are built from 25 diagnostic CT scans and refined for an object hierarchy based on a separate set of 20 diagnostic CT scans. Node detection is tested on an additional set of 20 PET/CT scans. Our preliminary results indicate node detection sensitivity and specificity at around 90% and 85%, respectively.

  17. Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography

    PubMed Central

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O’Connell, Avice M.; Conover, David L.

    2013-01-01

    This study retrospectively analyzed the mean glandular dose (MGD) to 133 breasts from 132 subjects, all women, who participated in a clinical trial evaluating dedicated breast CT in a diagnostic population. The clinical trial was conducted in adherence to a protocol approved by institutional review boards and the study participants provided written informed consent. Individual estimates of mean glandular dose to each breast from dedicated breast CT was obtained by combining x-ray beam characteristics with estimates of breast dimensions and fibroglandular fraction from volumetric breast CT images, and using normalized glandular dose coefficients. For each study participant and for the breast corresponding to that imaged with breast CT, an estimate of the MGD from diagnostic mammography (including supplemental views) was obtained from the DICOM image headers for comparison. This estimate uses normalized glandular dose coefficients corresponding to a breast with 50% fibroglandular weight fraction. The median fibroglandular weight fraction for the study cohort determined from volumetric breast CT images was 15%. Hence, the MGD from diagnostic mammography was corrected to be representative of the study cohort. Individualized estimates of MGD from breast CT ranged from 5.7 mGy to 27.8 mGy. Corresponding to the breasts imaged with breast CT, the MGD from diagnostic mammography ranged from 2.6 to 31.6 mGy. The mean (± inter-breast SD) and the median MGD (mGy) from dedicated breast CT exam were 13.9±4.6 and 12.6, respectively. For the corresponding breasts, the mean (± inter-breast SD) and the median MGD (mGy) from diagnostic mammography were 12.4±6.3 and 11.1, respectively. Statistical analysis indicated that at the 0.05 level, the distributions of MGD from dedicated breast CT and diagnostic mammography were significantly different (Wilcoxon signed ranks test, p = 0.007). While the interquartile range and the range (maximum-minimum) of MGD from dedicated breast CT was lower than diagnostic mammography, the median MGD from dedicated breast CT was approximately 13.5% higher than that from diagnostic mammography. The MGD for breast CT is based on a 1.45 mm skin layer and that for diagnostic mammography is based on a 4 mm skin layer; thus, favoring a lower estimate for MGD from diagnostic mammography. The median MGD from dedicated breast CT corresponds to the median MGD from 4 to 5 diagnostic mammography views. In comparison, for the same 133 breasts, the mean and the median number of views per breast during diagnostic mammography were 4.53 and 4, respectively. Paired analysis showed that there was approximately equal likelihood of receiving lower MGD from either breast CT or diagnostic mammography. Future work will investigate methods to reduce and optimize radiation dose from dedicated breast CT. PMID:24165162

  18. Effect of symptom-based risk stratification on the costs of managing patients with chronic rhinosinusitis symptoms.

    PubMed

    Tan, Bruce K; Lu, Guanning; Kwasny, Mary J; Hsueh, Wayne D; Shintani-Smith, Stephanie; Conley, David B; Chandra, Rakesh K; Kern, Robert C; Leung, Randy

    2013-11-01

    Current symptom criteria poorly predict a diagnosis of chronic rhinosinusitis (CRS) resulting in excessive treatment of patients with presumed CRS. The objective of this study was analyze the positive predictive value of individual symptoms, or symptoms in combination, in patients with CRS symptoms and examine the costs of the subsequent diagnostic algorithm using a decision tree-based cost analysis. We analyzed previously collected patient-reported symptoms from a cross-sectional study of patients who had received a computed tomography (CT) scan of their sinuses at a tertiary care otolaryngology clinic for evaluation of CRS symptoms to calculate the positive predictive value of individual symptoms. Classification and regression tree (CART) analysis then optimized combinations of symptoms and thresholds to identify CRS patients. The calculated positive predictive values were applied to a previously developed decision tree that compared an upfront CT (uCT) algorithm against an empiric medical therapy (EMT) algorithm with further analysis that considered the availability of point of care (POC) imaging. The positive predictive value of individual symptoms ranged from 0.21 for patients reporting forehead pain and to 0.69 for patients reporting hyposmia. The CART model constructed a dichotomous model based on forehead pain, maxillary pain, hyposmia, nasal discharge, and facial pain (C-statistic 0.83). If POC CT were available, median costs ($64-$415) favored using the upfront CT for all individual symptoms. If POC CT was unavailable, median costs favored uCT for most symptoms except intercanthal pain (-$15), hyposmia (-$100), and discolored nasal discharge (-$24), although these symptoms became equivocal on cost sensitivity analysis. The three-tiered CART model could subcategorize patients into tiers where uCT was always favorable (median costs: $332-$504) and others for which EMT was always favorable (median costs -$121 to -$275). The uCT algorithm was always more costly if the nasal endoscopy was positive. Among patients with classic CRS symptoms, the frequency of individual symptoms varied the likelihood of a CRS diagnosis marginally. Only hyposmia, the absence of facial pain, and discolored discharge sufficiently increased the likelihood of diagnosis to potentially make EMT less costly. The development of an evidence-based, multisymptom-based risk stratification model could substantially affect the management costs of the subsequent diagnostic algorithm. © 2013 ARS-AAOA, LLC.

  19. Subtraction coronary CT angiography using second-generation 320-detector row CT.

    PubMed

    Yoshioka, Kunihiro; Tanaka, Ryoichi; Muranaka, Kenta; Sasaki, Tadashi; Ueda, Takanori; Chiba, Takuya; Takeda, Kouta; Sugawara, Tsuyoshi

    2015-06-01

    The purpose of this study was to explore the feasibility of subtraction coronary computed tomography angiography (CCTA) by second-generation 320-detector row CT in patients with severe coronary artery calcification using invasive coronary angiography (ICA) as the gold standard. This study was approved by the institutional board, and all subjects provided written consent. Twenty patients with calcium scores of >400 underwent conventional CCTA and subtraction CCTA followed by ICA. A total of 82 segments were evaluated for image quality using a 4-point scale and the presence of significant (>50 %) luminal stenosis by two independent readers. The average image quality was 2.3 ± 0.8 with conventional CCTA and 3.2 ± 0.6 with subtraction CCTA (P < 0.001). The percentage of segments with non-diagnostic image quality was 43.9 % on conventional CCTA versus 8.5 % on subtraction CCTA (P = 0.004). The segment-based diagnostic accuracy for detecting significant stenosis according to ICA revealed an area under the receiver operating characteristics curve of 0.824 (95 % confidence interval [CI], 0.750-0.899) for conventional CCTA and 0.936 (95 % CI 0.889-0.936) for subtraction CCTA (P = 0.001). The sensitivity, specificity, positive predictive value, and negative predictive value for conventional CCTA were 88.2, 62.5, 62.5, and 88.2 %, respectively, and for subtraction CCTA they were 94.1, 85.4, 82.1, and 95.3 %, respectively. As compared to conventional, subtraction CCTA using a second-generation 320-detector row CT showed improvement in diagnostic accuracy at segment base analysis in patients with severe calcifications.

  20. Limited diagnostic value of Dual-Time-Point (18)F-FDG PET/CT imaging for classifying solitary pulmonary nodules in granuloma-endemic regions both at visual and quantitative analyses.

    PubMed

    Chen, Song; Li, Xuena; Chen, Meijie; Yin, Yafu; Li, Na; Li, Yaming

    2016-10-01

    This study is aimed to compare the diagnostic power of using quantitative analysis or visual analysis with single time point imaging (STPI) PET/CT and dual time point imaging (DTPI) PET/CT for the classification of solitary pulmonary nodules (SPN) lesions in granuloma-endemic regions. SPN patients who received early and delayed (18)F-FDG PET/CT at 60min and 180min post-injection were retrospectively reviewed. Diagnoses are confirmed by pathological results or follow-ups. Three quantitative metrics, early SUVmax, delayed SUVmax and retention index(the percentage changes between the early SUVmax and delayed SUVmax), were measured for each lesion. Three 5-point scale score was given by blinded interpretations performed by physicians based on STPI PET/CT images, DTPI PET/CT images and CT images, respectively. ROC analysis was performed on three quantitative metrics and three visual interpretation scores. One-hundred-forty-nine patients were retrospectively included. The areas under curve (AUC) of the ROC curves of early SUVmax, delayed SUVmax, RI, STPI PET/CT score, DTPI PET/CT score and CT score are 0.73, 0.74, 0.61, 0.77 0.75 and 0.76, respectively. There were no significant differences between the AUCs in visual interpretation of STPI PET/CT images and DTPI PET/CT images, nor in early SUVmax and delayed SUVmax. The differences of sensitivity, specificity and accuracy between STPI PET/CT and DTPI PET/CT were not significantly different in either quantitative analysis or visual interpretation. In granuloma-endemic regions, DTPI PET/CT did not offer significant improvement over STPI PET/CT in differentiating malignant SPNs in both quantitative analysis and visual interpretation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. The diagnostic value of single-photon emission computed tomography/computed tomography for severe sacroiliac joint dysfunction.

    PubMed

    Tofuku, Katsuhiro; Koga, Hiroaki; Komiya, Setsuro

    2015-04-01

    We aimed to evaluate the value of single-photon emission computed tomography (SPECT)/computed tomography (CT) for the diagnosis of sacroiliac joint (SIJ) dysfunction. SPECT/CT was performed in 32 patients with severe SIJ dysfunction, who did not respond to 1-year conservative treatment and had a score of >4 points on a 10-cm visual analog scale. We investigated the relationship between the presence of severe SIJ dysfunction and tracer accumulation, as confirmed by SPECT/CT. In cases of bilateral SIJ dysfunction, we also compared the intensity of tracer accumulation on each side. Moreover, we examined the relationship between the intensity of tracer accumulation and the different treatments the patients subsequently received. All 32 patients with severe SIJ dysfunction had tracer accumulation with a standardized uptake value (SUV) of >2.2 (mean SUV 4.7). In the 19 patients with lateralized symptom intensity, mean SUVs of the dominant side were significantly higher than those of the nondominant side. In 10 patients with no lateralization, the difference in the SUVs between sides was <0.6. Patients exhibiting higher levels of tracer accumulation required more advanced treatment. Patients with higher levels of tracer accumulation had greater symptom severity and also required more advanced treatment. Thus, we believe that SPECT/CT may be a suitable supplementary diagnostic modality for SIJ dysfunction as well as a useful technique for predicting the prognosis of this condition.

  2. A multicenter, randomized controlled trial of immediate total-body CT scanning in trauma patients (REACT-2)

    PubMed Central

    2012-01-01

    Background Computed tomography (CT) scanning has become essential in the early diagnostic phase of trauma care because of its high diagnostic accuracy. The introduction of multi-slice CT scanners and infrastructural improvements made total-body CT scanning technically feasible and its usage is currently becoming common practice in several trauma centers. However, literature provides limited evidence whether immediate total-body CT leads to better clinical outcome then conventional radiographic imaging supplemented with selective CT scanning in trauma patients. The aim of the REACT-2 trial is to determine the value of immediate total-body CT scanning in trauma patients. Methods/design The REACT-2 trial is an international, multicenter randomized clinical trial. All participating trauma centers have a multi-slice CT scanner located in the trauma room or at the Emergency Department (ED). All adult, non-pregnant, severely injured trauma patients according to predefined criteria will be included. Patients in whom direct scanning will hamper necessary cardiopulmonary resuscitation or who require an immediate operation because of imminent death (both as judged by the trauma team leader) are excluded. Randomization will be computer assisted. The intervention group will receive a contrast-enhanced total-body CT scan (head to pelvis) during the primary survey. The control group will be evaluated according to local conventional trauma imaging protocols (based on ATLS guidelines) supplemented with selective CT scanning. Primary outcome will be in-hospital mortality. Secondary outcomes are differences in mortality and morbidity during the first year post trauma, several trauma work-up time intervals, radiation exposure, general health and quality of life at 6 and 12 months post trauma and cost-effectiveness. Discussion The REACT-2 trial is a multicenter randomized clinical trial that will provide evidence on the value of immediate total-body CT scanning during the primary survey of severely injured trauma patients. If immediate total-body CT scanning is found to be the best imaging strategy in severely injured trauma patients it could replace conventional imaging supplemented with CT in this specific group. Trial Registration ClinicalTrials.gov: (NCT01523626). PMID:22458247

  3. Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) Combined with Positron Emission Tomography-Computed Tomography (PET-CT) and Video-Electroencephalography (VEEG) Have Excellent Diagnostic Value in Preoperative Localization of Epileptic Foci in Children with Epilepsy.

    PubMed

    Wang, Gui-Bin; Long, Wei; Li, Xiao-Dong; Xu, Guang-Yin; Lu, Ji-Xiang

    2017-01-01

    BACKGROUND To investigate the effect that dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has on surgical decision making relative to video-electroencephalography (VEEG) and positron emission tomography-computed tomography (PET-CT), and if the differences in these variables translates to differences in surgical outcomes. MATERIAL AND METHODS A total of 166 children with epilepsy undergoing preoperative DCE-MRI, VEEG, and PET-CT examinations, surgical resection of epileptic foci, and intraoperative electrocorticography (ECoG) monitoring were enrolled. All children were followed up for 12 months and grouped by Engles prognostic classification for epilepsy. Based on intraoperative ECoG as gold standard, the diagnostic values of DCE-MRI, VEEG, PET-CT, DCE-MRI combined with VEEG, DCE-MRI combined with PET-CT, and combined application of DCE-MRI, VEEG, and PET-CT in preoperative localization for epileptic foci were evaluated. RESULTS The sensitivity of DCE-MRI, VEEG, and PET-CT was 59.64%, 76.51%, and 93.98%, respectively; the accuracy of DCE-MRI, VEEG, PET-CT, DCE-MRI combined with VEEG, and DCE-MRI combined with PET-CT was 57.58%, 67.72%, 91.03%, 91.23%, and 96.49%, respectively. Localization accuracy rate of the combination of DCE-MRI, VEEG, and PET-CT was 98.25% (56/57), which was higher than that of DCE-MRI combined with VEEG and of DCE-MRI combined with PET-CT. No statistical difference was found in the accuracy rate of localization between these three combined techniques. During the 12-month follow-up, children were grouped into Engles grade I (n=106), II (n=31), III (n=21), and IV (n=8) according to postoperative conditions. CONCLUSIONS All DCE-MRI combined with VEEG, DCE-MRI combined with PET-CT, and DCE-MRI combined with VEEG and PET-CT examinations have excellent accuracy in preoperative localization of epileptic foci and present excellent postoperative efficiency, suggesting that these combined imaging methods are suitable for serving as the reference basis in preoperative localization of epileptic foci in children with epilepsy.

  4. Diagnostic accuracy of high-definition CT coronary angiography in high-risk patients.

    PubMed

    Iyengar, S S; Morgan-Hughes, G; Ukoumunne, O; Clayton, B; Davies, E J; Nikolaou, V; Hyde, C J; Shore, A C; Roobottom, C A

    2016-02-01

    To assess the diagnostic accuracy of computed tomography coronary angiography (CTCA) using a combination of high-definition CT (HD-CTCA) and high level of reader experience, with invasive coronary angiography (ICA) as the reference standard, in high-risk patients for the investigation of coronary artery disease (CAD). Three hundred high-risk patients underwent HD-CTCA and ICA. Independent experts evaluated the images for the presence of significant CAD, defined primarily as the presence of moderate (≥ 50%) stenosis and secondarily as the presence of severe (≥ 70%) stenosis in at least one coronary segment, in a blinded fashion. HD-CTCA was compared to ICA as the reference standard. No patients were excluded. Two hundred and six patients (69%) had moderate and 178 (59%) had severe stenosis in at least one vessel at ICA. The sensitivity, specificity, positive predictive value, and negative predictive value were 97.1%, 97.9%, 99% and 93.9% for moderate stenosis, and 98.9%, 93.4%, 95.7% and 98.3%, for severe stenosis, on a per-patient basis. The combination of HD-CTCA and experienced readers applied to a high-risk population, results in high diagnostic accuracy comparable to ICA. Modern generation CT systems in experienced hands might be considered for an expanded role. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Development of a computed tomography-based scoring system for necrotizing soft-tissue infections.

    PubMed

    McGillicuddy, Edward A; Lischuk, Andrew W; Schuster, Kevin M; Kaplan, Lewis J; Maung, Adrian; Lui, Felix Y; Bokhari, S A Jamal; Davis, Kimberly A

    2011-04-01

    Necrotizing soft-tissue infections (NSTIs) are associated with significant morbidity and mortality, but a definitive nonsurgical diagnostic test remains elusive. Despite the widespread use of computed tomography (CT) as a diagnostic adjunct, there is little data that definitively correlate CT findings with the presence of NSTI. Our goal was the development of a CT-based scoring system to discriminate non-NSTI from NSTI. Patients older than 17 years undergoing CT for evaluation of soft-tissue infection at a tertiary care medical center over a 10-year period (2000-2009) were included. Abstracted data included comorbidities and social history, physical examination, laboratory findings, and operative and pathologic findings. NSTI was defined as soft-tissue necrosis in the dictated operative note or the accompanying pathology report. CT scans were reviewed by a radiologist blinded to clinical and laboratory data. A scoring system was developed and the area under the receiver operating characteristic curve was calculated. During the study period, 305 patients underwent CT scanning (57% men; mean age, 47.4 years). Forty-four patients (14.4%) evaluated had an NSTI. A scoring system was retrospectively developed (table). A score >6 points was 86.3% sensitive and 91.5% specific for the diagnosis of NSTI (positive predictive value, 63.3%; negative predictive value, 85.5%). The area under the receiver operating characteristic curve was 0.928 (95% confidence interval, 0.893-0.964). The mean score of the non-NSTI group was 2.74. We have developed a CT scoring system that is both sensitive and specific for the diagnosis of NSTIs. This system may allow clinicians to more accurately diagnose NSTIs. Prospective validation of this scoring system is planned.

  6. Bicuspid aortic valves: diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT.

    PubMed

    Murphy, David J; McEvoy, Sinead H; Iyengar, Sri; Feuchtner, Gudrun; Cury, Ricardo C; Roobottom, Carl; Baumueller, Stephan; Alkadhi, Hatem; Dodd, Jonathan D

    2014-08-01

    To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P=0.001). Kappa analysis=0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥ 3.8 cm(2), 3.2 cm and 1.6mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P<0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54-1.0), 100%, 100% and 70% respectively. The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT features. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Computed Tomography Perfusion Improves Diagnostic Accuracy in Acute Posterior Circulation Stroke.

    PubMed

    Sporns, Peter; Schmidt, Rene; Minnerup, Jens; Dziewas, Rainer; Kemmling, André; Dittrich, Ralf; Zoubi, Tarek; Heermann, Philipp; Cnyrim, Christian; Schwindt, Wolfram; Heindel, Walter; Niederstadt, Thomas; Hanning, Uta

    2016-01-01

    Computed tomography perfusion (CTP) has a high diagnostic value in the detection of acute ischemic stroke in the anterior circulation. However, the diagnostic value in suspected posterior circulation (PC) stroke is uncertain, and whole brain volume perfusion is not yet in widespread use. We therefore studied the additional value of whole brain volume perfusion to non-contrast CT (NCCT) and CT angiography source images (CTA-SI) for infarct detection in patients with suspected acute ischemic PC stroke. This is a retrospective review of patients with suspected stroke in the PC in a database of our stroke center (n = 3,011) who underwent NCCT, CTA and CTP within 9 h after stroke onset and CT or MRI on follow-up. Images were evaluated for signs and pc-ASPECTS locations of ischemia. Three imaging models - A (NCCT), B (NCCT + CTA-SI) and C (NCCT + CTA-SI + CTP) - were compared with regard to the misclassification rate relative to gold standard (infarction in follow-up imaging) using the McNemar's test. Of 3,011 stroke patients, 267 patients had a suspected stroke in the PC and 188 patients (70.4%) evidenced a PC infarct on follow-up imaging. The sensitivity of Model C (76.6%) was higher compared with that of Model A (21.3%) and Model B (43.6%). CTP detected significantly more ischemic lesions, especially in the cerebellum, posterior cerebral artery territory and thalami. Our findings in a large cohort of consecutive patients show that CTP detects significantly more ischemic strokes in the PC than CTA and NCCT alone. © 2016 S. Karger AG, Basel.

  8. Prospective comparison of 68Ga-PSMA PET/CT, 18F-sodium fluoride PET/CT and diffusion weighted-MRI at for the detection of bone metastases in biochemically recurrent prostate cancer.

    PubMed

    Zacho, Helle D; Nielsen, Julie B; Afshar-Oromieh, Ali; Haberkorn, Uwe; deSouza, Nandita; De Paepe, Katja; Dettmann, Katja; Langkilde, Niels C; Haarmark, Christian; Fisker, Rune V; Arp, Dennis T; Carl, Jesper; Jensen, Jørgen B; Petersen, Lars J

    2018-06-06

    To prospectively compare diagnostic accuracies for detection of bone metastases by 68 Ga-PSMA PET/CT, 18 F-NaF PET/CT and diffusion-weighted MRI (DW 600 -MRI) in prostate cancer (PCa) patients with biochemical recurrence (BCR). Sixty-eight PCa patients with BCR participated in this prospective study. The patients underwent 68 Ga-PSMA PET/CT, a 18 F-NaF PET/CT and a DW 600 -MRI (performed in accordance with European Society of Urogenital Radiology guidelines, with b values of 0 and 600 s/mm 2 ). Bone lesions were categorized using a three-point scale (benign, malignant or equivocal for metastases) and a dichotomous scale (benign or metastatic) for each imaging modality by at least two experienced observers. A best valuable comparator was defined for each patient based on study-specific imaging, at least 12 months of clinical follow-up and any imaging prior to the study and during follow-up. Diagnostic performance was assessed using a sensitivity analysis where equivocal lesions were handled as non-metastatic and then as metastatic. Ten of the 68 patients were diagnosed with bone metastases. On a patient level, sensitivity, specificity and the area under the curve (AUC) by receiver operating characteristic analysis were, respectively, 0.80, 0.98-1.00 and 0.89-0.90 for 68 Ga-PSMA PET/CT (n = 68 patients); 0.90, 0.90-0.98 and 0.90-0.94 for 18 NaF PET/CT (n = 67 patients); and 0.25-0.38, 0.87-0.92 and 0.59-0.62 for DW 600 -MRI (n = 60 patients). The diagnostic performance of DW 600 -MRI was significantly lower than that of 68 Ga-PSMA PET/CT and 18 NaF PET/CT for diagnosing bone metastases (p < 0.01), and no significant difference in the AUC was seen between 68 Ga-PSMA PET/CT and 18 NaF PET/CT (p = 0.65). 68 Ga-PSMA PET/CT and 18 F-NaF PET/CT showed comparable and high diagnostic accuracies for detecting bone metastases in PCa patients with BCR. Both methods performed significantly better than DW 600 -MRI, which was inadequate for diagnosing bone metastases when conducted in accordance with European Society of Urogenital Radiology guidelines.

  9. Prospective evaluation of fluciclovine (18F) PET-CT and MRI in detection of recurrent prostate cancer in non-prostatectomy patients.

    PubMed

    Akin-Akintayo, Oladunni; Tade, Funmilayo; Mittal, Pardeep; Moreno, Courtney; Nieh, Peter T; Rossi, Peter; Patil, Dattatraya; Halkar, Raghuveer; Fei, Baowei; Master, Viraj; Jani, Ashesh B; Kitajima, Hiroumi; Osunkoya, Adeboye O; Ormenisan-Gherasim, Claudia; Goodman, Mark M; Schuster, David M

    2018-05-01

    To investigate the disease detection rate, diagnostic performance and interobserver agreement of fluciclovine ( 18 F) PET-CT and multiparametric magnetic resonance imaging (mpMR) in recurrent prostate cancer. Twenty-four patients with biochemical failure after non-prostatectomy definitive therapy, 16/24 of whom had undergone brachytherapy, underwent fluciclovine PET-CT and mpMR with interpretation by expert readers blinded to patient history, PSA and other imaging results. Reference standard was established via a multidisciplinary truth panel utilizing histology and clinical follow-up (22.9 ± 10.5 months) and emphasizing biochemical control. The truth panel was blinded to investigative imaging results. Diagnostic performance and interobserver agreement (kappa) for the prostate and extraprostatic regions were calculated for each of 2 readers for PET-CT (P1 and P2) and 2 different readers for mpMR (M1 and M2). On a whole body basis, the detection rate for fluciclovine PET-CT was 94.7% (both readers), while it ranged from 31.6-36.8% for mpMR. Kappa for fluciclovine PET-CT was 0.90 in the prostate and 1.0 in the extraprostatic regions. For mpMR, kappa was 0.25 and 0.74, respectively. In the prostate, 22/24 patients met the reference standard with 13 malignant and 9 benign results. Sensitivity, specificity and positive predictive value (PPV) were 100.0%, 11.1% and 61.9%, respectively for both PET readers. For mpMR readers, values ranged from 15.4-38.5% for sensitivity, 55.6-77.8% for specificity and 50.0-55.6% for PPV. For extraprostatic disease determination, 18/24 patients met the reference standard. Sensitivity, specificity and PPV were 87.5%, 90.0% and 87.5%, respectively, for fluciclovine PET-CT, while for mpMR, sensitivity ranged from 50 to 75%, specificity 70-80% and PPV 57-75%. The disease detection rate for fluciclovine PET-CT in non-prostatectomy patients with biochemical failure was 94.7% versus 31.6-36.8% for mpMR. For extraprostatic disease detection, fluciclovine PET-CT had overall better diagnostic performance than mpMR. For the treated prostate, fluciclovine PET-CT had high sensitivity though low specificity for disease detection, while mpMR had higher specificity, though low sensitivity. Interobserver agreement was also higher with fluciclovine PET-CT compared with mpMR. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Renal Complex Cystic Masses: Usefulness of Contrast-Enhanced Ultrasound (CEUS) in Their Assessment and Its Agreement with Computed Tomography.

    PubMed

    Sanz, Enrique; Hevia, Vital; Gómez, Victoria; Álvarez, Sara; Fabuel, Jose-Javier; Martínez, Laura; Rodriguez-Patrón, Rafael; González-Gordaliza, Cristina; Burgos, Francisco-Javier

    2016-12-01

    Around 10 % of renal cell carcinomas (RCC) are cystic, while some benign cysts have complex appearance in conventional diagnostic tests such as computed tomography (CT) or magnetic resonance imaging (MRI). These renal complex cystic masses (RCCMs) are a challenging entity in urological practice and sometimes have a difficult management, requiring surgical removal. Contrast-enhanced ultrasound (CEUS) is a very sensitive test detecting microvascularization in real time, and it has been used in the diagnostic workup of these kinds of lesions. The aim of our study was to assess the diagnostic power of CEUS in the evaluation of RCCM. This is a prospective observational study between April 2011 and July 2014. A total of 66 patients with 67 RCCMs were enrolled (Bosniak 2-4). Twenty-four patients underwent surgical removal of the RCCM. All participants underwent CEUS (experimental) and CT (control). All CEUS procedures were performed by a single high-experienced observer (urologist). Benign lesions were defined as those Bosniak 2-2F, and malignant were Bosniak 3-4. Statistical analysis was made measuring consistency (kappa index and Landis-Koch scale) and validity (sensitivity, specificity, positive and negative predictive values) of the study. Median size of RCCM measured by CEUS and CT was 3.8 cm (interquartile range (AIQ) 3.2-4.6) and 3.9 cm (AIQ 3.2-4.5), respectively. Kappa index shows good agreement between both tests (0.71; 95 % CI 0.57-0.85), both overall and stratified by categories according to Bosniak classification. CEUS has a sensitivity 100 %, specificity 81.4 %, positive predictive value 70.4 %, and negative predictive value 100 %. A total of eight RCCMs were discordant, and seven of eight classified as malignant by CEUS and not by CT. Of those seven lesions classified as malignant by CEUS, six (six of seven, 85.7 %) were malignant in the pathological exam. CEUS is a very useful tool for assessing RCCM, with good results in terms of consistency and validity. It has a good diagnostic power, with a sensitivity of 100 % and a negative predictive value of 100 %. Its main limitations are the experience required, a special software, and being observer-dependent.

  11. CT-guided brachytherapy of prostate cancer: reduction of effective dose from X-ray examination

    NASA Astrophysics Data System (ADS)

    Sanin, Dmitriy B.; Biryukov, Vitaliy A.; Rusetskiy, Sergey S.; Sviridov, Pavel V.; Volodina, Tatiana V.

    2014-03-01

    Computed tomography (CT) is one of the most effective and informative diagnostic method. Though the number of CT scans among all radiographic procedures in the USA and European countries is 11% and 4% respectively, CT makes the highest contribution to the collective effective dose from all radiographic procedures, it is 67% in the USA and 40% in European countries [1-5]. Therefore it is necessary to understand the significance of dose value from CT imaging to a patient . Though CT dose from multiple scans and potential risk is of great concern in pediatric patients, this applies to adults as well. In this connection it is very important to develop optimal approaches to dose reduction and optimization of CT examination. International Commission on Radiological Protection (ICRP) in its publications recommends radiologists to be aware that often CT image quality is higher than it is necessary for diagnostic confidence[6], and there is a potential to reduce the dose which patient gets from CT examination [7]. In recent years many procedures, such as minimally invasive surgery, biopsy, brachytherapy and different types of ablation are carried out under guidance of computed tomography [6;7], and during a procedures multiple CT scans focusing on a specific anatomic region are performed. At the Clinics of MRRC different types of treatment for patients with prostate cancer are used, incuding conformal CT-guided brachytherapy, implantation of microsources of I into the gland under guidance of spiral CT [8]. So, the purpose of the study is to choose optimal method to reduce radiation dose from CT during CT-guided prostate brachytherapy and to obtain the image of desired quality.

  12. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study

    PubMed Central

    Grosser, Oliver S.; Kupitz, Dennis; Ruf, Juri; Czuczwara, Damian; Steffen, Ingo G.; Furth, Christian; Thormann, Markus; Loewenthal, David; Ricke, Jens; Amthauer, Holger

    2015-01-01

    Background Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT) or positron emission tomography (PET) with computed tomography (CT). Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR) on the image quality of the low-dose CT images. Methodology/Principal Findings Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU) values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88) and the contrast-to-noise ratio (CNR) was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04). In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001). Conclusion/Significance In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality. PMID:26390216

  13. Imaging modalities in the diagnosis of pancreatic adenocarcinoma: A systematic review and meta-analysis of sensitivity, specificity and diagnostic accuracy.

    PubMed

    Toft, James; Hadden, William J; Laurence, Jerome M; Lam, Vincent; Yuen, Lawrence; Janssen, Anna; Pleass, Henry

    2017-07-01

    Pancreatic cancer, primarily pancreatic ductal adenocarcinoma (PDAC), accounts for 2.4% of cancer diagnoses and 5.8% of cancer death annually. Early diagnoses can improve 5-year survival in PDAC. The aim of this systematic review was to determine the sensitivity, specificity and diagnostic accuracy values for MRI, CT, PET&PET/CT, EUS and transabdominal ultrasound (TAUS) in the diagnosis of PDAC. A systematic review was undertaken to identify studies reporting sensitivity, specificity and/or diagnostic accuracy for the diagnosis of PDAC with MRI, CT, PET, EUS or TAUS. Proportional meta-analysis was performed for each modality. A total of 5399 patients, 3567 with PDAC, from 52 studies were included. The sensitivity, specificity and diagnostic accuracy were 93% (95% CI=88-96), 89% (95% CI=82-94) and 90% (95% CI=86-94) for MRI; 90% (95% CI=87-93), 87% (95% CI=79-93) and 89% (95% CI=85-93) for CT; 89% (95% CI=85-93), 70% (95% CI=54-84) and 84% (95% CI=79-89) for PET; 91% (95% CI=87-94), 86% (95% CI=81-91) and 89% (95% CI=87-92) for EUS; and 88% (95% CI=86-90), 94% (95% CI=87-98) and 91% (95% C=87-93) for TAUS. This review concludes all modalities, except for PET, are equivalent within 95% confidence intervals for the diagnosis of PDAC. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Filter paper-assisted cell transfer (FaCT) technique: A novel cell-sampling technique for intraoperative diagnosis of central nervous system tumors.

    PubMed

    Kawamura, Jumpei; Kamoshida, Shingo; Shimakata, Takaaki; Hayashi, Yurie; Sakamaki, Kuniko; Denda, Tamami; Kawai, Kenji; Kuwao, Sadahito

    2017-04-01

    Intraoperative diagnosis of central nervous system (CNS) tumors provides critical guidance to surgeons in the determination of surgical resection margins and treatment. The techniques and preparations used for the intraoperative diagnosis of CNS tumors include frozen sectioning and cytologic methods (squash smear and touch imprint). Cytologic specimens, which do not have freezing artifacts, are important as an adjuvant tool to frozen sections. However, if the amount of submitted tissue samples is limited, then it is difficult to prepare both frozen sections and squash smears or touch imprint specimens from a single sample at the same time. Therefore, the objective of this study was to derive cells directly from filter paper on which tumor samples are placed. The authors established the filter paper-assisted cell transfer (FaCT) smear technique, in which tumor cells are transferred onto a glass slide directly from the filter paper sample spot after the biopsy is removed. Cell yields and diagnostic accuracy of the FaCT smears were assessed in 40 CNS tumors. FaCT smears had ample cell numbers and well preserved cell morphology sufficient for cytologic diagnosis, even if the submitted tissues were minimal. The overall diagnostic concordance rates between frozen sections and FaCT smears were 90% and 87.5%, respectively (no significant differences). When combining FaCT smears with frozen sections, the diagnostic concordance rate rose to 92.5%. The current results suggest that the FaCT smear technique is a simple and effective processing method that has significant value for intraoperative diagnosis of CNS tumors. Cancer Cytopathol 2017;125:277-282. © 2016 American Cancer Society. © 2017 American Cancer Society.

  15. Ga-68-DOTA-TATE PET/CT for discrimination of tumors of the optic pathway.

    PubMed

    Klingenstein, Annemarie; Haug, Alexander R; Miller, Christina; Hintschich, Christoph

    2015-02-01

    Symptomatic tumors of the optic nerve pathway may endanger vision. They are difficult to classify by imaging alone and biopsy may damage visual function. Tumor pathology influences treatment decision and a diagnostic tool with a high sensitivity and specificity would therefore be invaluable. We hypothesized that Ga-68-DOTA-TATE PET/CT may help in discriminating optic nerve tumors as uptake of somatostatin is elevated in meningiomas. Ga-68-DOTA-TATE PET/CT was used to examine 13 patients with ambiguous, symptomatic lesions of the optic pathway for treatment planning. The presence or absence of meningioma was validated by histopathology or supplementary diagnostic work-up. Ga-68-DOTA-TATE PET/CT identified 10 meningiomas (en plaque = 1, optic nerve sheath = 4, sphenoidal = 5) correctly via increased SSTR (somatostatin receptor) expression (mean SUVmax (maximum standardized uptake value) = 14.3 ± 15.4). 3 tumors did not show elevated Ga-68-DOTA-TATE uptake (SUVmax = 2.1 ± 1.0). Subsumizing all clinical-radiological follow-up tools available, these lesions were classified as an intracerebral metastasis of an advanced gastric carcinoma, histologically proven inflammatory collagenous connective tissue and presumed leukemic infiltration of a newly diagnosed chronic lymphocytic leukemia. In this case series, Ga-68-DOTA-TATE PET/CT demonstrated both a sensitivity and specificity of 100%. Yet, the golden standard of histopathology was only available in a subset of patients included. Ga-68-DOTA-TATE PET/CT proved to be a valuable diagnostic tool for the correct classification of equivocal, symptomatic tumors of the anterior optic pathway requiring therapy. PET/CT results influenced therapy decision essentially in all cases.

  16. The value of preoperative computed tomography combined with ultrasound in the investigation of small indeterminate liver lesions in patients with colorectal cancer.

    PubMed

    Abraham-Nordling, Mirna; Öistämö, Emma; Josephson, Thomas; Hjern, Fredrik; Blomqvist, Lennart

    2017-11-01

    Background Computed tomography (CT) is used routinely for the preoperative detection of colorectal cancer (CRC) metastases. When small indeterminate focal liver lesions are detected that are too small to characterize (TSTC) on CT, additional imaging is usually needed, resulting in a potential delay in obtaining a complete diagnostic work-up. Purpose To determine the diagnostic accuracy of ultrasound (US) of the liver performed in direct conjunction to CT in the preoperative investigation among patients with newly diagnosed CRC when indeterminate liver lesions were found on CT. Material and Methods Preoperative investigations with CT and consecutive US where CT had shown at least one focal liver lesion in 74 patients diagnosed with CRC between June 2009 and February 2012 were retrospectively reviewed. Either histopathological findings or a combination of imaging and clinical follow-up one to three years after surgery was used as the reference. Results Liver metastases were diagnosed with CT/US in 13 out of 74 patients (17.6%). In one patient, a liver cyst was preoperatively regarded as liver metastasis by a combined CT/US. The sensitivity and specificity for the CT with consecutive US procedure was 100% (13/13) and 98.4% (60/61). Conclusion US performed in conjunction with CT in patients with indeterminate focal liver lesions on CT is an accurate work-up for detection of liver metastases in patients with newly diagnosed CRC. Although our results are promising, they cannot be considered safely generalizable to all hospitals.

  17. C-Arm Cone-Beam CT-Guided Transthoracic Lung Core Needle Biopsy as a Standard Diagnostic Tool

    PubMed Central

    Jaconi, Marta; Pagni, Fabio; Vacirca, Francesco; Leni, Davide; Corso, Rocco; Cortinovis, Diego; Bidoli, Paolo; Bono, Francesca; Cuttin, Maria S.; Valente, Maria G.; Pesci, Alberto; Bedini, Vittorio A.; Leone, Biagio E.

    2015-01-01

    Abstract C-arm cone-beam computed tomography (CT)-guided transthoracic lung core needle biopsy (CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. This article will focus on the clinical features related to CNB in terms of diagnostic performance and complication rate. Moreover, the concept of categorizing pathological diagnosis into 4 categories, which could be used for clinical management, follow-up, and quality assurance is also introduced. We retrospectively collected data regarding 375 C-arm cone-beam CT-guided CNBs from January 2010 and June 2014. Clinical and radiological variables were evaluated in terms of success or failure rate. Pathological reports were inserted in 4 homogenous groups (nondiagnostic-L1, benign-L2, malignant not otherwise specified-L3, and malignant with specific histotype-L4), defining for each category a hierarchy of suggested actions. The sensitivity, specificity, and positive and negative predictive value and accuracy for patients subjected to CNBs were of 96.8%, 100%, 100%, 100%, and 97.2%, respectively. Roughly 75% of our samples were diagnosed as malignant, with 60% lung adenocarcinoma diagnoses. Molecular analyses were performed on 85 malignant samples to verify applicability of targeted therapy. The rate of “nondiagnostic” samples was 12%. C-arm cone-beam CT-guided transthoracic lung CNB can represent the gold standard for the diagnostic evaluation of pulmonary nodules. A clinical and pathological multidisciplinary evaluation of CNBs was needed in terms of integration of radiological, histological, and oncological data. This approach provided exceptional performances in terms of specificity, positive and negative predictive values; sensitivity in our series was lower compared with other large studies, probably due to the application of strong criteria of adequacy for CNBs (L1 class rate). The satisfactory rate of collected material was evaluated not only in terms of merely diagnostic performances but also for predictive results by molecular analysis. PMID:25816042

  18. C-arm cone-beam CT-guided transthoracic lung core needle biopsy as a standard diagnostic tool: an observational study.

    PubMed

    Jaconi, Marta; Pagni, Fabio; Vacirca, Francesco; Leni, Davide; Corso, Rocco; Cortinovis, Diego; Bidoli, Paolo; Bono, Francesca; Cuttin, Maria S; Valente, Maria G; Pesci, Alberto; Bedini, Vittorio A; Leone, Biagio E

    2015-03-01

    C-arm cone-beam computed tomography (CT)-guided transthoracic lung core needle biopsy (CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. This article will focus on the clinical features related to CNB in terms of diagnostic performance and complication rate. Moreover, the concept of categorizing pathological diagnosis into 4 categories, which could be used for clinical management, follow-up, and quality assurance is also introduced. We retrospectively collected data regarding 375 C-arm cone-beam CT-guided CNBs from January 2010 and June 2014. Clinical and radiological variables were evaluated in terms of success or failure rate. Pathological reports were inserted in 4 homogenous groups (nondiagnostic--L1, benign--L2, malignant not otherwise specified--L3, and malignant with specific histotype--L4), defining for each category a hierarchy of suggested actions. The sensitivity, specificity, and positive and negative predictive value and accuracy for patients subjected to CNBs were of 96.8%, 100%, 100%, 100%, and 97.2%, respectively. Roughly 75% of our samples were diagnosed as malignant, with 60% lung adenocarcinoma diagnoses. Molecular analyses were performed on 85 malignant samples to verify applicability of targeted therapy. The rate of "nondiagnostic" samples was 12%. C-arm cone-beam CT-guided transthoracic lung CNB can represent the gold standard for the diagnostic evaluation of pulmonary nodules. A clinical and pathological multidisciplinary evaluation of CNBs was needed in terms of integration of radiological, histological, and oncological data. This approach provided exceptional performances in terms of specificity, positive and negative predictive values; sensitivity in our series was lower compared with other large studies, probably due to the application of strong criteria of adequacy for CNBs (L1 class rate). The satisfactory rate of collected material was evaluated not only in terms of merely diagnostic performances but also for predictive results by molecular analysis.

  19. Value of repeat CT scans in low back pain and radiculopathy.

    PubMed

    Schroeder, Josh E; Barzilay, Yair; Kaplan, Leon; Itshayek, Eyal; Hiller, Nurith

    2016-02-01

    We assessed the clinical value of repeat spine CT scan in 108 patients aged 18-60 years who underwent repeat lumbar spine CT scan for low back pain or radiculopathy from January 2008 to December 2010. Patients with a neoplasm or symptoms suggesting underlying disease were excluded from the study. Clinical data was retrospectively reviewed. Index examinations and repeat CT scan performed at a mean of 24.3 ± 11.3 months later were compared by a senior musculoskeletal radiologist. Disc abnormalities (herniation, sequestration, bulge), spinal stenosis, disc space narrowing, and bony changes (osteophytes, fractures, other changes) were documented. Indications for CT scan were low back pain (60 patients, 55%), radiculopathy (46 patients, 43%), or nonspecific back pain (two patients, 2%). A total of 292 spine pathologies were identified in 98 patients (90.7%); in 10 patients (9.3%) no spine pathology was seen on index or repeat CT scan. At repeat CT scan, 269/292 pathologies were unchanged (92.1%); 10/292 improved (3.4%), 8/292 worsened (2.8%, disc herniation or spinal stenosis), and five new pathologies were identified. No substantial therapeutic change was required in patients with worsened or new pathology. Added diagnostic value from repeat CT scan performed within 2-3 years was rare in patients suffering chronic or recurrent low back pain or radiculopathy, suggesting that repeat CT scan should be considered only in patients with progressive neurologic deficits, new neurologic complaints, or signs implying serious underlying conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. External ultrasonography of the neck does not add diagnostic value to integrated positron emission tomography-computed tomography (PET-CT) scanning in the diagnosis of cervical lymph node metastases in patients with esophageal carcinoma.

    PubMed

    Blom, R L G M; Vliegen, R F A; Schreurs, W M J; Belgers, H J; Stohr, I; Oostenbrug, L E; Sosef, M N

    2012-08-01

    One of the objectives of preoperative imaging in esophageal cancer patients is the detection of cervical lymph node metastases. Traditionally, external ultrasonography of the neck has been combined with computed tomography (CT) in order to improve the detection of cervical metastases. In general, integrated positron emission tomography-computed tomography (PET-CT) has been shown to be superior to CT or PET regarding staging and therefore may limit the role of external ultrasonography of the neck. The objective of this study was to determine the additional value of external ultrasonography of the neck to PET-CT. This study included all patients referred our center for treatment of esophageal carcinoma. Diagnostic staging was performed to determine treatment plan. Cervical lymph nodes were evaluated by external ultrasonography of the neck and PET-CT. In case of suspect lymph nodes on external ultrasonography or PET-CT, fine needle aspiration (FNA) was performed. Between 2008 and 2010, 170 out of 195 referred patients underwent both external ultrasonography of the neck and PET-CT. Of all patients, 84% were diagnosed with a tumor at or below the distal esophagus. In 140 of 170 patients, the cervical region was not suspect; no FNA was performed. Seven out of 170 patients had suspect nodes on both PET-CT and external ultrasonography. Five out of seven patients had cytologically confirmed malignant lymph nodes, one of seven had benign nodes, in one patient FNA was not performed; exclusion from esophagectomy was based on intra-abdominal metastases. In one out of 170 patients, PET-CT showed suspect nodes combined with a negative external ultrasonography; cytology of these nodes was benign. Twenty-two out of 170 patients had a negative PET-CT with suspect nodes on external ultrasonography. In 18 of 22 patients, cervical lymph nodes were cytologically confirmed benign; in four patients, FNA was not possible or inconclusive. At a median postoperative follow-up of 15 months, only 1% of patients developed cervical lymph node metastases. This study shows no additional value of external ultrasonography to a negative PET-CT. According to our results, it can be omitted in the primary workup. However, suspect lymph nodes on PET-CT should be confirmed by FNA to exclude false positives if it would change treatment plan. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  1. Evaluation of Rib Fractures on a Single-in-plane Image Reformation of the Rib Cage in CT Examinations.

    PubMed

    Dankerl, Peter; Seuss, Hannes; Ellmann, Stephan; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2017-02-01

    This study aimed to evaluate the diagnostic performance of using a reformatted single-in-plane image reformation of the rib cage for the detection of rib fractures in computed tomography (CT) examinations, employing different levels of radiological experience. We retrospectively evaluated 10 consecutive patients with and 10 patients without rib fractures, whose CT scans were reformatted to a single-in-plane image reformation of the rib cage. Eight readers (two radiologists, two residents in radiology, and four interns) independently evaluated the images for the presence of rib fractures using a reformatted single-in-plane image and a multi-planar image reformation. The time limit was 30 seconds for each read. A consensus of two radiologist readings was considered as the reference standard. Diagnostic performance (sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]) was assessed and evaluated per rib and per location (anterior, lateral, posterior). To determine the time limit, we prospectively analyzed the average time it took radiologists to assess the rib cage, in a bone window setting, in 50 routine CT examinations. McNemar test was used to compare the diagnostic performances. Single image reformation was successful in all 20 patients. The sensitivity, specificity, PPV, and NPV for the detection of rib fractures using the conventional multi-planar read were 77.5%, 99.2%, 89.9%, and 98.0% for radiologists; 46.3%, 99.7%, 92.5%, and 95.3% for residents; and 29.4%, 99.4%, 82.5%, and 93.9% for interns, respectively. Sensitivity, PPV, and NPV increased across all three groups of experience, using the reformatted single-in-plane image of the rib cage (radiologists: 85.0%, 98.6%, and 98.7%; residents: 80.0%, 92.8%, and 98.2%; interns: 66.9%, 89.9%, and 97.1%), whereas specificity did not change significantly (99.9%, 99.4%, and 99.3%). The diagnostic performance of the interns and residents was significantly better when evaluating the single-in-plane image reformations (P < .01). The diagnostic performance of the radiologists was better when evaluating the single-in-plane image reformations; however, there was no significant difference (statistical power: 0.32). The diagnostic performance for the detection of rib fractures, using CT images that have been reformatted to a single-in-plane image, improves for readers from different educational levels when the evaluation time is restricted to 30 seconds or less. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  2. Diagnostic value of quantitative assessment of cardiac 18F-fluoro-2-deoxyglucose uptake in suspected cardiac sarcoidosis.

    PubMed

    Lebasnier, Adrien; Legallois, Damien; Bienvenu, Boris; Bergot, Emmanuel; Desmonts, Cédric; Zalcman, Gérard; Agostini, Denis; Manrique, Alain

    2018-06-01

    The identification of cardiac sarcoidosis is challenging as there is no gold standard consensually admitted for its diagnosis. The aim of this study was to evaluate the diagnostic value of the assessment of cardiac dynamic 18 F-fluoro-2-deoxyglucose positron emission tomography ( 18 F-FDG PET/CT) and net influx constant (Ki) in patients suspected of cardiac sarcoidosis. Data obtained from 30 biopsy-proven sarcoidosis patients suspected of cardiac sarcoidosis who underwent a 50-min list-mode cardiac dynamic 18 F-FDG PET/CT after a 24 h high-fat and low-carbohydrate diet were analyzed. A normalized coefficient of variation of quantitative glucose influx constant, calculated as the ratio: standard deviation of the segmental Ki (min -1 )/global Ki (min -1 ) was determined using a validated software (Carimas ® 2.4, Turku PET Centre). Cardiac sarcoidosis was diagnosed according to the Japanese Ministry of Health and Welfare criteria. Receiving operating curve analysis was performed to determine sensitivity and specificity of cardiac dynamic 18 F-FDG PET/CT analysis to diagnose cardiac sarcoidosis. Six out of 30 patients (20%) were diagnosed as having cardiac sarcoidosis. Myocardial glucose metabolism was significantly heterogeneous in patients with cardiac sarcoidosis who showed significantly higher normalized coefficient of variation values compared to patients without cardiac sarcoidosis (0.513 ± 0.175 vs. 0.205 ± 0.081; p = 0.0007). Using ROC curve analysis, we found a cut-off value of 0.38 for the diagnosis of cardiac sarcoidosis with a sensitivity of 100% and a specificity of 91%. Our results suggest that quantitative analysis of cardiac dynamic 18 F-FDG PET/CT could be a useful tool for the diagnosis of cardiac sarcoidosis.

  3. Diagnostic Performance of 11C-choline PET/CT and FDG PET/CT in Prostate Cancer.

    PubMed

    Kitajima, Kazuhiro; Yamamoto, Shingo; Odawara, Soichi; Kobayashi, Kaoru; Fujiwara, Masayuki; Kamikonya, Norihiko; Fukushima, Kazuhito; Nakanishi, Yukako; Hashimoto, Takahiko; Yamada, Yusuke; Suzuki, Toru; Kanematsu, Akihiro; Nojima, Michio; Yamakado, Koichiro

    2018-06-01

    We compared 11C-choline and FDG PET/CT scan findings for the staging and restaging of prostate cancer. Twenty Japanese prostate cancer patients underwent 11C-choline and FDG PET/CT before (n=5) or after (n=15) treatment. Using a five-point scale, we compared these scanning modalities regarding patient- and lesion-based diagnostic performance for local recurrence, untreated primary tumor, and lymph node and bony metastases. Of the 20 patients, documented local lesions, and node and bony metastases were present in 11 (55.0%), 9 (45.0%), and 13 (65.0%), respectively. The patient-based sensitivity/specificity/accuracy/area under the receiver-operating-characteristic curve (AUC) values for 11C-choline-PET/CT for diagnosing local lesions were 90.9% /100%/ 95.0% / 1.0, whereas those for FDG-PET/CT were 45.5% /100%/ 75.0% / 0.773. Those for 11C-choline-PET/CT for node metastasis were 88.9% /100%/ 95.0% / 0.944, and those for FDG-PET/CT were 44.4%/100%/75.0%/0.722. Those for 11C-choline-PET/CT for bone metastasis were 84.6%/100%/90.0%/0.951, and those for FDG-PET/CT were 76.9% /100%/ 85.0% / 0.962. The AUCs for local lesion and node metastasis differed significantly (p=0.0039, p=0.011, respectively). The lesion-based detection rates of 11C-choline compared to FDG PET/CT for local lesion, and node and bone metastases were 91.7% vs. 41.7%, 92.0% vs. 32.0%, and 94.8% vs. 83.0% (p=0.041, p=0.0030, p<0.0001), respectively. 11C-choline-PET/CT is more useful for the staging and restaging of prostate cancer than FDG-PET/CT in Japanese men.

  4. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study

    PubMed Central

    Cirla, A.; Rondena, M.; Bertolini, G.

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses. PMID:27540512

  5. Intra-arterial Ultra-low-Dose CT Angiography of Lower Extremity in Diabetic Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Özgen, Ali, E-mail: draliozgen@hotmail.com; Sanioğlu, Soner; Bingöl, Uğur Anıl

    2016-08-15

    PurposeTo image lower extremity arteries by CT angiography using a very low-dose intra-arterial contrast medium in patients with high risk of developing contrast-induced nephropathy (CIN).Materials and MethodsThree cases with long-standing diabetes mellitus and signs of lower extremity atherosclerotic disease were evaluated by CT angiography using 0.1 ml/kg of the body weight of contrast medium given via 10-cm-long 4F introducer by puncturing the CFA. Images were evaluated by an interventional radiologist and a cardiovascular surgeon. Density values of the lower extremity arteries were also calculated. Findings in two cases were compared with digital subtraction angiography images performed for percutaneous revascularization. Blood creatininemore » levels were followed for possible CIN.ResultsIntra-arterial CT angiography images were considered diagnostic in all patients and optimal in one patient. No patient developed CIN after intra-arterial CT angiography, while one patient developed CIN after percutaneous intervention.ConclusionIntra-arterial CT angiography of lower extremity might be performed in selected patients with high risk of developing CIN. Our limited experience suggests that as low as of 0.1 ml/kg of the body weight of contrast medium may result in adequate diagnostic imaging.« less

  6. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study.

    PubMed

    Cirla, A; Rondena, M; Bertolini, G

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.

  7. Comparison of the accuracy of cone beam computed tomography and medical computed tomography: implications for clinical diagnostics with guided surgery.

    PubMed

    Abboud, Marcus; Calvo-Guirado, Jose Luis; Orentlicher, Gary; Wahl, Gerhard

    2013-01-01

    This study compared the accuracy of cone beam computed tomography (CBCT) and medical-grade CT in the context of evaluating the diagnostic value and accuracy of fiducial marker localization for reference marker-based guided surgery systems. Cadaver mandibles with attached radiopaque gutta-percha markers, as well as glass balls and composite cylinders of known dimensions, were measured manually with a highly accurate digital caliper. The objects were then scanned using a medical-grade CT scanner (Philips Brilliance 64) and five different CBCT scanners (Sirona Galileos, Morita 3D Accuitomo 80, Vatech PaX-Reve3D, 3M Imtech Iluma, and Planmeca ProMax 3D). The data were then imported into commercially available software, and measurements were made of the scanned markers and objects. CT and CBCT measurements were compared to each other and to the caliper measurements. The difference between the CBCT measurements and the caliper measurements was larger than the difference between the CT measurements and the caliper measurements. Measurements of the cadaver mandible and the geometric reference markers were highly accurate with CT. The average absolute errors of the human mandible measurements were 0.03 mm for CT and 0.23 mm for CBCT. The measurement errors of the geometric objects based on CT ranged between 0.00 and 0.12 mm, compared to an error range between 0.00 and 2.17 mm with the CBCT scanners. CT provided the most accurate images in this study, closely followed by one CBCT of the five tested. Although there were differences in the distance measurements of the hard tissue of the human mandible between CT and CBCT, these differences may not be of clinical significance for most diagnostic purposes. The fiducial marker localization error caused by some CBCT scanners may be a problem for guided surgery systems.

  8. Lesion detection performance: comparative analysis of low-dose CT data of the chest on two hybrid imaging systems.

    PubMed

    Jessop, Maryam; Thompson, John D; Coward, Joanne; Sanderud, Audun; Jorge, José; de Groot, Martijn; Lança, Luís; Hogg, Peter

    2015-03-01

    Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). JAFROC analysis showed a significant difference (P < 0.0001) in lesion detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  9. Myocardial perfusion imaging with PET

    PubMed Central

    Nakazato, Ryo; Berman, Daniel S; Alexanderson, Erick; Slomka, Piotr

    2013-01-01

    PET-myocardial perfusion imaging (MPI) allows accurate measurement of myocardial perfusion, absolute myocardial blood flow and function at stress and rest in a single study session performed in approximately 30 min. Various PET tracers are available for MPI, and rubidium-82 or nitrogen-13-ammonia is most commonly used. In addition, a new fluorine-18-based PET-MPI tracer is currently being evaluated. Relative quantification of PET perfusion images shows very high diagnostic accuracy for detection of obstructive coronary artery disease. Dynamic myocardial blood flow analysis has demonstrated additional prognostic value beyond relative perfusion imaging. Patient radiation dose can be reduced and image quality can be improved with latest advances in PET/CT equipment. Simultaneous assessment of both anatomy and perfusion by hybrid PET/CT can result in improved diagnostic accuracy. Compared with SPECT-MPI, PET-MPI provides higher diagnostic accuracy, using lower radiation doses during a shorter examination time period for the detection of coronary artery disease. PMID:23671459

  10. Diagnostic value of CT, PET and combined PET/CT performed with low-dose unenhanced CT and full-dose enhanced CT in the initial staging of lymphoma.

    PubMed

    Pinilla, I; Gómez-León, N; Del Campo-Del Val, L; Hernandez-Maraver, D; Rodríguez-Vigil, B; Jover-Díaz, R; Coya, J

    2011-10-01

    The aim of this paper was to compare the accuracy of contrast-enhanced computed tomography (CT), positron emission tomography (PET), unenhanced low-dose PET/CT (LD-PET/CT) and full-dose enhanced PET/CT (FD-PET/CT) for the initial staging of lymphoma. One hundred and one lymphoma patients were examined by [18F]FDG-PET/CT including unenhanced low-dose CT and enhanced full-dose CT. Each modality of PET/CT was evaluated by a nuclear medicine physician and a radiologist unaware of the other modality, while the CT and PET images were interpreted separately by another independent radiologist and nuclear medicine physician respectively. The nodal and extranodal lesions detected by each technique were compared with a reference standard. For nodal assessment, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative LR (LR-) of LD-PET/CT were 97%, 96%, 98%, 95%, 26 and 0.02 respectively, and those of FD-PET/CT were 97%, 97%, 98%, 95%, 36 and 0.02. These results were significantly better than those of PET (sensitivity 82%, specificity 81%, PPV 88%, NPV 72%, LR+ 4.3, LR- 0.21). Likewise, both PET/CT displayed a higher sensitivity, NPV and LR- than CT (91%, 84%, 0.1 respectively). For organ evaluation, both modalities of PET/CT also had significantly better sensitivity and NPV than that of PET (LD-PET/CT: sensitivity 92%, NPV 90%; FD-PET/CT sensitivity 94%, NPV 92%; PET: sensitivity 70%, NPV 69%). The sensitivity, specificity, PPV and NPV for bone marrow involvement were 29%, 84%, 45% and 72% respectively for PET, and 29%, 90%, 56%, and 74% for both, LD-PET/CT, and FD-PET/CT. No significant differences were found between LD-PET/CT and FD-PET/CT, but FD-PET/CT detected important incidental findings in 5.9% of patients. PET/CT is an accurate technique for the initial staging of lymphomas without significant differences between LD-PET/CT and FD-PET/CT. FD-PET/CT detects relevant incidental findings that are missed on LD-PET/CT.

  11. Small (≤ 2 cm) hepatocellular carcinoma in patients with chronic liver disease: comparison of gadoxetic acid-enhanced 3.0 T MRI and multiphasic 64-multirow detector CT.

    PubMed

    Hwang, J; Kim, S H; Lee, M W; Lee, J Y

    2012-07-01

    To compare the diagnostic performance of gadoxetic acid-enhanced MRI using 3.0 T with that of multiphasic 64-multirow detector CT (MDCT) for the detection of small (≤2 cm) hepatocellular carcinoma (HCC) in patients with chronic liver disease. A total of 54 patients (44 men, 10 women; age range, 33-81 years) with 59 HCCs (≤2 cm in diameter) who underwent both multiphasic (arterial, portal venous, equilibrium) 64-MDCT and gadoxetic acid-enhanced 3.0 T MRI were enrolled in this study. Two observers independently and randomly reviewed the MR and CT images on a lesion-by-lesion basis. The diagnostic performance of these techniques for the detection of HCC was assessed by alternative free-response receiver operating characteristic (ROC) analysis, in addition to evaluating the sensitivity and positive predictive value. For each observer, the areas under the ROC curve were 0.874 and 0.863 for MRI, respectively, as opposed to 0.660 and 0.687 for CT, respectively. The differences between the two techniques were statistically significant for each observer (p<0.001). The sensitivities (89.8% and 86.4%) of MRI for both observers were significantly higher than those (57.6% and 61.0% for each observer, respectively) of MDCT. No significant difference was seen between the positive predictive values for the two techniques (p>0.05). Gadoxetic acid-enhanced 3.0 T MRI shows a better diagnostic performance than that of 64-MDCT for the detection of small (≤2 cm) HCCs in patients with chronic liver disease.

  12. Congenitally absent lumbar pedicle: a reappraisal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wortzman, G.; Steinhardt, M.I.

    1984-09-01

    Three patients who had a diagnosis of congenitally absent lumbar pedicle underwent CT examination. Findings showed that each patient had an aberrant hypoplastic pedicle plus a retroisthmic defect in their ipsilateral lamina rather than an absent pedicle. Axial CT was the diagnostic modality of choice; reformated images were of little value. The differential diagnosis to be considered from the findings of plain film radiography includes pediculate thinning, neoplastic disease, neurofibroma, mesodermal dysplasia associated with neurofibromatosis, and vascular anomalies.

  13. Comparison Between 64Cu-PSMA-617 PET/CT and 18F-Choline PET/CT Imaging in Early Diagnosis of Prostate Cancer Biochemical Recurrence.

    PubMed

    Cantiello, Francesco; Crocerossa, Fabio; Russo, Giorgio Ivan; Gangemi, Vincenzo; Ferro, Matteo; Vartolomei, Mihai Dorin; Lucarelli, Giuseppe; Mirabelli, Maria; Scafuro, Chiara; Ucciero, Giuseppe; De Cobelli, Ottavio; Morgia, Giuseppe; Damiano, Rocco; Cascini, Giuseppe Lucio

    2018-06-04

    To evaluate the diagnostic performance of 64 Cu-PSMA-617 positron emission tomography (PET) with computed tomography (CT) for restaging prostate cancer after biochemical recurrence (BCR) and to compare it with 18 F-choline PET/CT in a per-patient analysis. An observational study was performed of 43 patients with BCR after laparoscopic radical prostatectomy who underwent 64 Cu-PSMA-617 PET/CT and subsequently 18 F-choline PET/CT for restaging. The detection rates (DR) of 64 Cu-PSMA-617 PET/CT and of 18 F-choline PET/CT were calculated by standardized maximum uptake value (SUV max ) at 4 hours and SUV max at 1 hour as reference, respectively. Furthermore, univariate logistic regression analysis was carried out to identify independent predictive factors of positivity with 64 Cu-PSMA-617 PET/CT. An overall positivity with 64 Cu-PSMA-617 PET/CT was found in 32 patients (74.4%) versus 19 (44.2%) with 18 F-choline PET/CT. Specifically, after stratifying for prostate-specific antigen (PSA) values, we found a good performance of 64 Cu-PSMA-617 PET/CT at low PSA levels compared to 18 F-choline PET/CT, with a DR of 57.1% versus 14.3% for PSA 0.2-0.5 ng/mL (P = .031), and of 60% versus 30% with PSA 0.5-1 ng/mL. At univariate binary logistic regression analysis, PSA level was the only independent predictor of 64 Cu-PSMA-617 PET/CT positivity. No significant difference in terms of DR for both 64 Cu-PSMA-617 PET/CT and 18 F-choline PET/CT was found according to different Gleason score subgroups. In our study cohort, a better performance was observed for 64 Cu-PSMA-617 PET/CT compared to 18 F-choline PET/CT in restaging after BCR, especially in patients with low PSA values. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. CT Bronchus Sign and the Diagnostic Yield of Guided Bronchoscopy for Peripheral Pulmonary Lesions: A Systematic Review and Meta-Analysis.

    PubMed

    Ali, Muhammad S; Sethi, Jaskaran; Taneja, Amit; Musani, Ali; Maldonado, Fabien

    2018-06-07

    Indeterminate peripheral pulmonary lesions often require tissue diagnosis. If non-surgical biopsy techniques are considered, deciding between bronchoscopic transbronchial vs. CT guided transthoracic biopsy can be difficult. The former has a low diagnostic yield with a low complication risk, while the latter has a better diagnostic yield but a higher complication rate. Investigators have looked at various lesion characteristics that can predict the diagnostic yield of guided bronchoscopic biopsies. While consensus exists that larger size and proximity to the hilum increase the diagnostic yield, there is ongoing debate about the association between CT bronchus sign (air-filled bronchus in close proximity of the lesion as seen on CT) and the diagnostic yield of guided bronchoscopic modalities. To perform a meta-analysis and systematic review, determining the association between CT bronchus sign and the diagnostic yield of guided bronchoscopy for peripheral pulmonary lesions. MEDLINE, Embase, Scopus and Google Scholar were searched in January 2018 for guided bronchoscopy studies that had assessed the impact of CT bronchus sign on the diagnostic yield. The quality of included studies was assessed using Quality Assessment, Data Abstraction and Synthesis-2 tool. Meta-analysis was performed using MedCalc (version 18). Odds ratios were used to compare yield of lesions with and without bronchus sign. Random effects model was used when significant heterogeneity was observed (I2>40%). For 2199 lesions with CT bronchus sign, the overall weighted diagnostic yield was 74.1% (95% CI: 68.3-79.5%). For 971 lesions without CT bronchus sign, the overall weighted diagnostic yield was 49.6% (95% CI: 39.6-59.5%). The odds ratio for successfully diagnosing a lesion with CT bronchus was 3.4 (95% CI: 2.4-5.0). Possible sources of heterogeneity in the meta-analysis included differences in study designs, guidance modalities and cancer prevalence. The odds ratio for successfully diagnosing a lesion with CT bronchus sign was relatively lower for prospective studies. Peripheral pulmonary lesions with CT bronchus sign are more likely to be diagnosed with guided bronchoscopy as compared to the lesions without CT bronchus sign. Clinicians should consider this along with the lesion size and distance from hilum, when contemplating guided bronchoscopy for peripheral pulmonary lesions. To perform a meta-analysis and systematic review, determining the impact of CT bronchus sign on the diagnostic yield of guided bronchoscopy for peripheral pulmonary lesions. MEDLINE, Embase, Scopus and Google Scholar were searched in January 2018 for guided bronchoscopy studies that had assessed the impact of CT bronchus sign on the diagnostic yield. The quality of included studies was assessed using Quality Assessment, Data Abstraction and Synthesis-2 tool. Meta-analysis was performed using MedCalc (version 18). Odds ratios were used to compare yield of lesions with and without bronchus sign. Random effects model was used when significant heterogeneity was observed (I2>40%). For 2199 lesions with CT bronchus sign, the overall weighted diagnostic yield was 74.1% (95% CI: 68.3-79.5%). For 971 lesions without CT bronchus, the overall weighted diagnostic yield was 49.6% (95% CI: 39.6-59.5%). The odds ratio for successfully diagnosing a lesion with CT bronchus was 3.4 (95% CI: 2.4-5.0). I² index was 62.1 therefore random effects model was used. Peripheral pulmonary lesions with CT bronchus sign are much more likely to be successfully diagnosed with guided bronchoscopy as compared to the lesions without CT bronchus sign. Clinicians should consider the presence (or absence) of CT bronchus sign along with the size of the lesion and distance from the hilum, when contemplating guided bronchoscopic modalities for peripheral pulmonary lesions.

  15. Diagnostic accuracy of 18F-FDG PET/CT for assessing response to radiofrequency ablation treatment in lung metastases: a multicentre prospective study.

    PubMed

    Bonichon, Françoise; Palussière, Jean; Godbert, Yann; Pulido, Marina; Descat, Edouard; Devillers, Anne; Meunier, Catherine; Leboulleux, Sophie; de Baère, Thierry; Galy-Lacour, Claire; Lagoarde-Segot, Laurent; Cazeau, Anne-Laure

    2013-12-01

    To assess diagnostic accuracy of (18)F-FDG PET/CT at 3 months for the detection of local recurrence after radiofrequency ablation (RFA) of lung metastases. The PET/CT scan at 3 months was compared with a baseline PET/CT scan from a maximum of 2 months before RFA, with the reference standard as recurrence diagnosed by CT during a 12-month follow-up. Local recurrence was diagnosed on the PET/CT scan if lesional uptake was greater than the mediastinal background. Maximum standardized uptake values (SUVmax) were recorded. ROC curve analysis for SUVmax was performed. Overall survival (OS) and time to local relapse were computed from the date of RFA using the Kaplan-Meier method (www.clinicaltrials.gov: NCT 00382252). Between 2005 and 2009, 89 patients (mean age 65 years) underwent RFA for 115 lung metastases (mean size 16.2 ± 6.9 mm). The median SUVmax before RFA was 5.8 ± 4. PET/CT at 3 months and the reference standard were available in 77 patients and 100 lesions. Accuracy was 66.00% (95% CI 55.85-75.18%), sensitivity 90.91% (95 % CI 58.72-99.77 %), specificity 62.92% (95% CI 52.03-72.93%), PPV 23.26% (95% CI 11.76-38.63%), and NPV 98.25% (95% CI 90.61-99.96%). One-year OS was 94.2% (95% CI 86.6-97.5%) and the probability of being free of local recurrence 1 year after RFA was 84.6% (95% CI 75.0-90.8%). The specificity of PET/CT at 3 months is low because of persistent inflammation, especially when the lesion is close to the pleura. This technique is useful for its negative predictive value, but positive findings need to be confirmed by histology before new treatment is planned.

  16. Dynamic Contrast-Enhanced Perfusion Area-Detector CT: Preliminary Comparison of Diagnostic Performance for N Stage Assessment With FDG PET/CT in Non-Small Cell Lung Cancer.

    PubMed

    Ohno, Yoshiharu; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Yoshikawa, Takeshi

    2017-11-01

    The objective of our study was to directly compare the capability of dynamic first-pass contrast-enhanced (CE) perfusion area-detector CT (ADCT) and FDG PET/CT for differentiation of metastatic from nonmetastatic lymph nodes and assessment of N stage in patients with non-small cell lung carcinoma (NSCLC). Seventy-seven consecutive patients, 45 men (mean age ± SD, 70.4 ± 5.9 years) and 32 women (71.2 ± 7.7 years), underwent dynamic first-pass CE-perfusion ADCT at two or three different positions for covering the entire thorax, FDG PET/CT, surgical treatment, and pathologic examination. From all ADCT data for each of the subjects, a whole-chest perfusion map was computationally generated using the dual- and single-input maximum slope and Patlak plot methods. For quantitative N stage assessment, perfusion parameters and the maximum standardized uptake value (SUV max ) for each lymph node were determined by measuring the relevant ROI. ROC curve analyses were performed for comparing the diagnostic capability of each of the methods on a per-node basis. N stages evaluated by each of the indexes were then statistically compared with the final pathologic diagnosis by means of chi-square and kappa statistics. The area under the ROC curve (A z ) values of systemic arterial perfusion (A z = 0.89), permeability surface (A z = 0.78), and SUV max (A z = 0.85) were significantly larger than the A z values of total perfusion (A z = 0.70, p < 0.05) and distribution volume (A z = 0.55, p < 0.05). For each of the threshold values, agreement for systemic arterial perfusion calculated using the dual-input maximum slope model was substantial (κ = 0.70, p < 0.0001), and agreement for SUV max was moderate (κ = 0.60, p < 0.0001). Dynamic first-pass CE-perfusion ADCT is as useful as FDG PET/CT for the differentiation of metastatic from nonmetastatic lymph nodes and assessment of N stage in patients with NSCLC.

  17. The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.

    PubMed

    Vorona, G A; Zuccoli, G; Sutcavage, T; Clayton, B L; Ceschin, R C; Panigrahy, A

    2013-01-01

    Iterative reconstruction techniques facilitate CT dose reduction; though to our knowledge, no group has explored using iterative reconstruction with pediatric head CT. Our purpose was to perform a feasibility study to assess the use of ASIR in a small group of pediatric patients undergoing head CT. An Alderson-Rando head phantom was scanned at decreasing 10% mA intervals relative to our standard protocol, and each study was then reconstructed at 10% ASIR intervals. An intracranial region of interest was consistently placed to estimate noise. Our ventriculoperitoneal shunt CT protocol was subsequently modified, and patients were scanned at 20% ASIR with approximately 20% mA reductions. ASIR studies were anonymously compared with older non-ASIR studies from the same patients by 2 attending pediatric neuroradiologists for diagnostic utility, sharpness, noise, and artifacts. The phantom study demonstrated similar noise at 100% mA/0% ASIR (3.9) and 80% mA/20% ASIR (3.7). Twelve pediatric patients were scanned at reduced dose at 20% ASIR. The average CTDI(vol) and DLP values of the 20% ASIR studies were 22.4 mGy and 338.4 mGy-cm, and for the non-ASIR studies, they were 28.8 mGy and 444.5 mGy-cm, representing statistically significant decreases in the CTDI(vol) (22.1%, P = .00007) and DLP (23.9%, P = .0005) values. There were no significant differences between the ASIR studies and non-ASIR studies with respect to diagnostic acceptability, sharpness, noise, or artifacts. Our findings suggest that 20% ASIR can provide approximately 22% dose reduction in pediatric head CT without affecting image quality.

  18. Added value of 18F-FDG PET/CT in diagnosing infected hip prosthesis.

    PubMed

    Kwee, Robert M; Broos, Wouter Am; Brans, Boudewijn; Walenkamp, Geert Him; Geurts, Jan; Weijers, René E

    2018-05-01

    Background The diagnosis of infected hip prosthesis is frequently not straightforward yet very important as it changes treatment. Purpose To retrospectively investigate the added value of 18F-FDG PET/CT to conventional tests including radiography, erythrocyte sedimentation rate (ESR)/C-reactive protein (CRP) testing, and joint aspiration, in diagnosing infected hip prosthesis. Material and Methods Seventy-eight hip prostheses of 78 patients (55% men; mean age = 66.5 years; age range = 30-85 years) with non-specific clinical presentation, i.e. no abscess or sinus tract communicating with the joint space at clinical examination, were analyzed. Cultures of intra-articular fluid and peri-implant tissues after revision surgery or clinical follow-up ≥6 months served as gold standard. Areas under the receiver operating characteristic curves (AUCs) of radiography, ESR/CRP testing, aspiration culture, and white blood cell (WBC) count without and with the addition of 18F-FDG PET/CT were compared. Results The addition of 18F-FDG PET/CT increased AUCs: for radiography with 0.212, P = 0.001; for ESR/CRP testing with 0.076, P = 0.072; for aspiration culture with 0.126, P = 0.032; and for aspiration WBC count with 0.191, P = 0.035. Conclusion This study shows that 18F-FDG PET/CT adds to individual conventional tests in diagnosing infected hip prosthesis. It may improve the preoperative planning and should therefore be considered in the diagnostic work-up. Future studies should define the exact place of 18F-FDG PET/CT in the diagnostic work-up of periprosthetic joint infection.

  19. [Perforation of hollow organs in the abdominal contusion: diagnostic features and prognostic factors of death].

    PubMed

    Nicolau, A E; Merlan, V; Dinescu, G; Crăciun, M; Kitkani, A; Beuran, M

    2012-01-01

    Blunt hollow viscus perforations (HVP) due to abdominal contusions (AC), although rare, are difficult to diagnose early and are associated with a high mortality. Our paper analyses retrospectively data from patients operated for HVP between January 2005 and January 2009, the efficiency of different diagnostic tools, mortality and prognostic factors for death. There were 62 patients operated for HVP, 14 of which had isolated abdominal contusion and 48 were poly trauma patients. There were 9 women and 53 men, the mean age was 41.5 years (SD: +17,9), the mean ISS was 32.94 (SD: +15,94), 23 patients had associated solid viscus injuries (SVI). Clinical examination was irelevant for 16 of the 62 patients, abdominal Xray was false negative for 30 out of 35 patients and abdominal ultrasound was false negative for 16 out of 60 patients. Abdominal CT was initially false negative for 7 out of 38 patients: for 4 of them the abdominal CT was repeated and was positive for HVP, for 3 patients a diagnostic laparoscopy was performed. Direct signs for HVP on abdominal CT were present for 3 out of 38 patients. Diagnostic laparoscopy was performed for 7 patients with suspicion for HVP, and was positive for 6 of them and false negative for a patient with a duodenal perforation. Single organ perforations were present in 55 cases, multi organ perforations were present in 7 cases. There were 15 deaths (15.2%), most of them caused by haemodynamic instability (3 out of 6 patients) and associated lesions: SOL for 9 out of 23 cases, pelvic fracture (PF) for 6 out of 14 patients, craniocerebral trauma (CCT) for 12 out of 33 patients.Multivariate analysis showed that the prognostic factors for death were ISS value (p = 0,023) and associated CCT (odds ratio = 4,95; p = 0,017). The following factors were not confirmed as prognostic factors for death: age, haemodynamic instability, associated SVI, thoracic trauma (TT), pelvic fractures (PF), limbs fractures (LF) and admission-operation interval under 6 hours. Hollow viscus perforations due to abdominal contusions have a high mortality, early diagnosis is difficult, repeated abdominal CT and the selective use of diagnostic laparoscopy for haemodynamic stable patients with ambiguous clinical examination and diagnostic imaging are salutary. Prognostic factors for death were the ISS value and associated craniocerebral trauma.

  20. CT myocardial perfusion imaging: current status and future perspectives.

    PubMed

    Yang, Dong Hyun; Kim, Young-Hak

    2017-07-01

    Computed tomography myocardial perfusion (CTP) combined with coronary computed tomography angiography (CCTA) may constitute a "1-stop shop" for the noninvasive diagnosis of hemodynamically significant coronary stenosis during a single CT examination. CTP shows high diagnostic performance and provides incremental value over CCTA for the detection of hemodynamically significant coronary stenosis in patients with a high Agatston calcium score or coronary artery stents. Future studies should determine the optimal protocol and clinical value of CTP for guiding revascularization strategy and prognostication. In this article, we review the current status and future perspectives of CTP, focusing on technical considerations, clinical applications, and future research topics.

  1. [Value of quantitative iodine-based material decomposition images with gemstone spectral CT imaging in the follow-up of patients with hepatocellular carcinoma after TACE treatment].

    PubMed

    Xing, Gusheng; Wang, Shuang; Li, Chenrui; Zhao, Xinming; Zhou, Chunwu

    2015-03-01

    To investigate the value of quantitative iodine-based material decomposition images with gemstone spectral CT imaging in the follow-up of patients with hepatocellular carcinoma (HCC) after transcatheter arterial chemoebolization (TACE). Consecutive 32 HCC patients with previous TACE treatment were included in this study. For the follow-up, arterial phase (AP) and venous phase (VP) dual-phase CT scans were performed with a single-source dual-energy CT scanner (Discovery CT 750HD, GE Healthcare). Iodine concentrations were derived from iodine-based material-decomposition images in the liver parenchyma, tumors and coagulation necrosis (CN) areas. The iodine concentration difference (ICD) between the arterial-phase (AP) and venal-phase (VP) were quantitatively evaluated in different tissues.The lesion-to-normal parenchyma iodine concentration ratio (LNR) was calculated. ROC analysis was performed for the qualitative evaluation, and the area under ROC (Az) was calculated to represent the diagnostic ability of ICD and LNR. In all the 32 HCC patients, the region of interesting (ROI) for iodine concentrations included liver parenchyma (n=42), tumors (n=28) and coagulation necrosis (n=24). During the AP the iodine concentration of CNs (median value 0.088 µg/mm(3)) appeared significantly higher than that of the tumors (0.064 µg/mm(3), P=0.022) and liver parenchyma (0.048 µg/mm(3), P=0.005). But it showed no significant difference between liver parenchyma and tumors (P=0.454). During the VP the iodine concentration in hepatic parenchyma (median value 0.181 µg/mm(3)) was significantly higher than that in CNs (0.140 µg/mm(3), P=0.042). There was no significant difference between liver parenchyma and tumors, CNs and tumors (both P>0.05). The median value of ICD in CNs was 0.006 µg/mm(3), significantly lower than that of the HCC (0.201 µg/mm(3), P<0.001) and hepatic parenchyma (0.117 µg/mm(3), P<0.001). The ICDs in tumors and hepatic parenchyma showed no significant difference (P=0.829). During the AP, the LNR had no significant difference between CNs and tumors (a median value 1.805 vs. 1.310, P=0.389), and during the VP, the difference was also non-significant (the median value 0.647 vs. 0.713, P=0.660). The mean Az value of ICDs for evaluation of surviving tumor tissues was 0.804, whiles LNR measured a disappointing result in both AV images and VP images. Quantitative iodine-based material decomposition images with gemstone spectral CT imaging can improve the diagnostic efficacy of CT imaging for HCC patients after TACE treatment.

  2. [Diagnosis of septic loosening of hip prosthesis with LeukoScan. SPECT scan with 99mTc-labeled monoclonal antibodies].

    PubMed

    Kaisidis, A; Megas, P; Apostolopoulos, D; Spiridonidis, T; Koumoundourou, D; Zouboulis, P; Lambiris, E; Vassilakos, P

    2005-05-01

    Diagnosis of septic loosening of hip endoprosthesis with antigranulocyte scintigraphy (AGS) was analysed. Twenty-one hip prostheses were studied using laboratory tests and, in cases of elevated values, three-phase bone scan (BS) and AGS. Elective SPECT/CT scans were performed. Histologic and microbiologic exams verified the diagnosis. The AGS analysis revealed sensitivity, specificity and accuracy of value 1, while positive and negative predictive values were also 1. BS showed sensitivity of 1 and specificity of 0.33. In three cases, SPECT/CT scans corroborated the AGS interpretation. This diagnostic algorithm proved effective in the detection of septic loosening of hip prostheses. AGS can be avoided without risk of infection being overlooked.

  3. Diagnostic yield and accuracy of coronary CT angiography after abnormal nuclear myocardial perfusion imaging.

    PubMed

    Meinel, Felix G; Schoepf, U Joseph; Townsend, Jacob C; Flowers, Brian A; Geyer, Lucas L; Ebersberger, Ullrich; Krazinski, Aleksander W; Kunz, Wolfgang G; Thierfelder, Kolja M; Baker, Deborah W; Khan, Ashan M; Fernandes, Valerian L; O'Brien, Terrence X

    2018-06-15

    We aimed to determine the diagnostic yield and accuracy of coronary CT angiography (CCTA) in patients referred for invasive coronary angiography (ICA) based on clinical concern for coronary artery disease (CAD) and an abnormal nuclear stress myocardial perfusion imaging (MPI) study. We enrolled 100 patients (84 male, mean age 59.6 ± 8.9 years) with an abnormal MPI study and subsequent referral for ICA. Each patient underwent CCTA prior to ICA. We analyzed the prevalence of potentially obstructive CAD (≥50% stenosis) on CCTA and calculated the diagnostic accuracy of ≥50% stenosis on CCTA for the detection of clinically significant CAD on ICA (defined as any ≥70% stenosis or ≥50% left main stenosis). On CCTA, 54 patients had at least one ≥50% stenosis. With ICA, 45 patients demonstrated clinically significant CAD. A positive CCTA had 100% sensitivity and 84% specificity with a 100% negative predictive value and 83% positive predictive value for clinically significant CAD on a per patient basis in MPI positive symptomatic patients. In conclusion, almost half (48%) of patients with suspected CAD and an abnormal MPI study demonstrate no obstructive CAD on CCTA.

  4. A new technique for the diagnosis of acute appendicitis: abdominal CT with compression to the right lower quadrant.

    PubMed

    Kılınçer, Abidin; Akpınar, Erhan; Erbil, Bülent; Ünal, Emre; Karaosmanoğlu, Ali Devrim; Kaynaroğlu, Volkan; Akata, Deniz; Özmen, Mustafa

    2017-08-01

    To determine the diagnostic accuracy of abdominal CT with compression to the right lower quadrant (RLQ) in adults with acute appendicitis. 168 patients (age range, 18-78 years) were included who underwent contrast-enhanced CT for suspected appendicitis performed either using compression to the RLQ (n = 71) or a standard protocol (n = 97). Outer diameter of the appendix, appendiceal wall thickening, luminal content and associated findings were evaluated in each patient. Kruskal-Wallis, Fisher's and Pearson's chi-squared tests were used for statistical analysis. There was no significant difference in the mean outer diameter (MOD) between compression CT scans (10.6 ± 1.9 mm) and standard protocol (11.2 ± 2.3 mm) in patients with acute appendicitis (P = 1). MOD was significantly lower in the compression group (5.2 ± 0.8 mm) compared to the standard protocol (6.5 ± 1.1 mm) (P < 0.01) in patients without appendicitis. A cut-off value of 6.75 mm for the outer diameter of the appendix was found to be 100% sensitive in the diagnosis of acute appendicitis for both groups. The specificity was higher for compression CT technique (67.7 vs. 94.9%). Normal appendix diameter was significantly smaller in the compression-CT group compared to standard-CT group, increasing diagnostic accuracy of abdominal compression CT. • Normal appendix diameter is significantly smaller in compression CT. • Compression could force contrast material to flow through the appendiceal lumen. • Compression CT may be a CT counterpart of graded compression US.

  5. Avoiding delayed diagnosis of significant blunt bowel and mesenteric injuries: Can a scoring tool make the difference? A 7-year retrospective cohort study.

    PubMed

    Zingg, Tobias; Agri, Fabio; Bourgeat, Mylène; Yersin, Bertrand; Romain, Benoît; Schmidt, Sabine; Keller, Nathalie; Demartines, Nicolas

    2018-01-01

    Significant blunt bowel and mesenteric injuries (sBBMI) are frequently missed despite the widespread use of computed tomography (CT). Early treatment improves the outcome related to these injuries. The aim of this study was to assess the prevalence of sBBMI, the incidence of delayed diagnosis and to test the performance of the Bowel Injury Prediction Score (BIPS), determined by the white blood cell (WBC) count, presence or absence of abdominal tenderness and CT grade of mesenteric injury. Single-centre, registry-based retrospective cohort study, screening all consecutive trauma patients admitted to Lausanne University Hospital Trauma Centre from 2008 to 2015 after a road traffic accident. All patients with reliable information about the presence or absence of sBBMI who underwent abdominal CT and for whom calculation of the BIPS was possible were included for analysis. The incidence of delayed (>24h after admission) diagnosis in the patient group with sBBMI was determined and the diagnostic performance of the BIPS for sBBMI was assessed. For analysis, 766 patients with reliable information about the presence or absence of sBBMI were included. The prevalence of sBBMI was 3.1% (24/766). In 24% (5/21) of stable trauma patients undergoing CT, a diagnostic delay of more than 24h occurred. Abdominal tenderness (p<0.0001) and CT grade ≥4 (p<0.0001) were associated with sBBMI, whereas CT grade 4 alone (p=0.93) and WBC count ≥17G/l (p=0.30) were not. A BIPS ≥2 had a sensitivity of 89% (95% CI, 67-99), specificity of 89% (95% CI, 86-91), positive likelihood ratio of 8 (95% CI, 6.1-10), negative likelihood ratio of 0.12 (95% CI, 0.03-0.44), positive predictive value (PPV) of 19% (95% CI, 15-24) and negative predictive value (NPV) of 99.7% (95% CI, 98.7-99.9). CT alone identified 79% (15/19) and the BIPS 89% (17/19) of patients with sBBMI (p=0.66). Diagnostic delays in patients with sBBMI are common (24%), despite the routine use of abdominal CT. Application of the BIPS on the present cohort would have led to a high number of non-therapeutic abdominal explorations without identifying significantly more sBBMI early than CT alone. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Diagnostic accuracy of droplet digital PCR for detection of EGFR T790M mutation in circulating tumor DNA

    PubMed Central

    Tong, Xiang; Wang, Ye; Wang, Chengdi; Jin, Jing; Tian, Panwen; Li, Weimin

    2018-01-01

    Objectives Although different methods have been established to detect epidermal growth factor receptor (EGFR) T790M mutation in circulating tumor DNA (ctDNA), a wide range of diagnostic accuracy values were reported in previous studies. The aim of this meta-analysis was to provide pooled diagnostic accuracy measures for droplet digital PCR (ddPCR) in the diagnosis of EGFR T790M mutation based on ctDNA. Materials and methods A systematic review and meta-analysis were carried out based on resources from Pubmed, Web of Science, Embase and Cochrane Library up to October 11, 2017. Data were extracted to assess the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio (NLR), diagnostic OR (DOR), and areas under the summary receiver-operating characteristic curve (SROC). Results Eleven of 311 studies identified have met the including criteria. The sensitivity and specificity of ddPCR for the detection of T790M mutation in ctDNA ranged from 0.0% to 100.0% and 63.2% to 100.0%, respectively. For the pooled analysis, ddPCR had a performance of 70.1% (95% CI, 62.7%–76.7%) sensitivity, 86.9 % (95% CI, 80.6%–91.7%) specificity, 3.67 (95% CI, 2.33–5.79) PLR, 0.41 (95% CI, 0.32–0.55) NLR, and 10.83 (95% CI, 5.86–20.03) DOR, with the area under the SROC curve being 0.82. Conclusion The ddPCR harbored a good performance for detection of EGFR T790M mutation in ctDNA. PMID:29844700

  7. Utility of 18F-fluoro-deoxyglucose emission tomography/computed tomography fusion imaging (18F-FDG PET/CT) in combination with ultrasonography for axillary staging in primary breast cancer.

    PubMed

    Ueda, Shigeto; Tsuda, Hitoshi; Asakawa, Hideki; Omata, Jiro; Fukatsu, Kazuhiko; Kondo, Nobuo; Kondo, Tadaharu; Hama, Yukihiro; Tamura, Katsumi; Ishida, Jiro; Abe, Yoshiyuki; Mochizuki, Hidetaka

    2008-06-09

    Accurate evaluation of axillary lymph node (ALN) involvement is mandatory before treatment of primary breast cancer. The aim of this study is to compare preoperative diagnostic accuracy between positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (18F-FDG PET/CT) and axillary ultrasonography (AUS) for detecting ALN metastasis in patients having operable breast cancer, and to assess the clinical management of axillary 18F-FDG PET/CT for therapeutic indication of sentinel node biopsy (SNB) and preoperative systemic chemotherapy (PSC). One hundred eighty-three patients with primary operable breast cancer were recruited. All patients underwent 18F-FDG PET/CT and AUS followed by SNB and/or ALN dissection (ALND). Using 18F-FDG PET/CT, we studied both a visual assessment of 18F-FDG uptake and standardized uptake value (SUV) for axillary staging. In a visual assessment of 18F-FDG PET/CT, the diagnostic accuracy of ALN metastasis was 83% with 58% in sensitivity and 95% in specificity, and when cut-off point of SUV was set at 1.8, sensitivity, specificity, and accuracy were 36, 100, and 79%, respectively. On the other hand, the diagnostic accuracy of AUS was 85% with 54% in sensitivity and 99% in specificity. By the combination of 18F-FDG PET/CT and AUS to the axilla, the sensitivity, specificity, and accuracy were 64, 94, and 85%, respectively. If either 18F-FDG PET uptake or AUS was positive in allixa, the probability of axillary metastasis was high; 50% (6 of 12) in 18F-FDG PET uptake only, 80% (4 of 5) in AUS positive only, and 100% (28 of 28) in dual positive. By the combination of AUS and 18F-FDG PET/CT, candidates of SNB were more appropriately selected. The axillary 18F-FDG uptake was correlated with the maximum size and nuclear grade of metastatic foci (p = 0.006 and p = 0.03). The diagnostic accuracy of 18F-FDG PET/CT was shown to be nearly equal to ultrasound, and considering their limited sensitivities, the high radiation exposure by 18F-FDG PET/CT and also costs of the examination, it is likely that AUS will be more cost-effective in detecting massive axillary tumor burden. However, when we cannot judge the axillary staging using AUS alone, metabolic approach of 18F-FDG PET/CT for axillary staging would enable us a much more confident diagnosis.

  8. Diagnosis of Grave's disease with pulmonary hypertension on chest CT.

    PubMed

    Lee, Hwa Yeon; Yoo, Seung Min; Kim, Hye Rin; Chun, Eun Ju; White, Charles S

    To evaluate the diagnostic accuracy of chest CT findings to diagnose Grave's disease in pulmonary hypertension. We retrospectively evaluated chest CT and the medical records of 13 patients with Grave's disease with (n=6) or without pulmonary hypertension (n=7) and in 17 control patients. Presence of iso-attenuation of diffusely enlarged thyroid glands compared with adjacent neck muscle on non-enhanced CT as a diagnostic clue of Grave's disease, and assessment of pulmonary hypertension on CT has high diagnostic accuracy. Chest CT has the potential to diagnose Grave's disease with pulmonary hypertension in the absence of other information. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Clinical Significance of Fluorine-18-fluorodeoxyglucose Positron Emission Tomography/computed Tomography in the Follow-up of Colorectal Cancer: Searching off Approaches Increasing Specificity for Detection of Recurrence

    PubMed Central

    Okuyucu, Kursat; Hancerliogulları, Oguz; Alagoz, Engin; San, Huseyin; Arslan, Nuri

    2017-01-01

    Abstract Background Nearly 40% of colorectal cancer (CRC) recurs within 2 years after resection of primary tumor. Imaging with fluorine-18-fluorodeoxyglucose (l8F-FDG) positron emission tomography/computed tomography (PET/CT) is the most recent modality and often applied for the evaluation of metastatic spread during the follow-up period. Our goal was to study the diagnostic importance of 18F-FDG-PET/CT data of maximum standardized uptake value (SUVmax), total lesion glycolysis (TLG) and the difference of SUVmax on dual-time imaging in CRC. Patients and methods We examined the SUVmax value of lesions on control or restaging 18F-FDG-PET/CT of 53 CRC patients. All lesions with increased SUVmax values were confirmed by colonoscopy or histopathology. We compared PET/CT results with conventional imaging modalities (CT, MRI) and tumor markers (carbohydrate antigen 19-9 [Ca 19-9], carcinoembryonic antigen [CEA]). Results Mean SUVmax was 6.9 ± 5.6 in benign group, 12.7 ± 6.1 in malignant group. Mean TLG values of malignant group and benign group were 401 and 148, respectively. 18F-FDG-PET/CT was truely positive in 48% of patients with normal Ca 19-9 or CEA levels and truely negative in 10% of cases with elevated Ca 19-9 or CEA. CT or MRI detected suspicious malignancy in 32% of the patients and 18F-FDG-PET/CT was truely negative in 35% of these cases. We found the most important and striking statistical difference of TLG value between the groups with benign and recurrent disease. Conclusions Although SUVmax is a strong metabolic parameter (p = 0.008), TLG seems to be the best predictor in recurrence of CRC (p = 0.001); both are increasing the specificity of 18F-FDG-PET/CT. PMID:29333115

  10. Clinical Significance of Fluorine-18-fluorodeoxyglucose Positron Emission Tomography/computed Tomography in the Follow-up of Colorectal Cancer: Searching off Approaches Increasing Specificity for Detection of Recurrence.

    PubMed

    Ince, Semra; Okuyucu, Kursat; Hancerliogulları, Oguz; Alagoz, Engin; San, Huseyin; Arslan, Nuri

    2017-12-01

    Nearly 40% of colorectal cancer (CRC) recurs within 2 years after resection of primary tumor. Imaging with fluorine-18-fluorodeoxyglucose ( l8 F-FDG) positron emission tomography/computed tomography (PET/CT) is the most recent modality and often applied for the evaluation of metastatic spread during the follow-up period. Our goal was to study the diagnostic importance of 18 F-FDG-PET/CT data of maximum standardized uptake value (SUVmax), total lesion glycolysis (TLG) and the difference of SUVmax on dual-time imaging in CRC. We examined the SUVmax value of lesions on control or restaging 18 F-FDG-PET/CT of 53 CRC patients. All lesions with increased SUVmax values were confirmed by colonoscopy or histopathology. We compared PET/CT results with conventional imaging modalities (CT, MRI) and tumor markers (carbohydrate antigen 19-9 [Ca 19-9], carcinoembryonic antigen [CEA]). Mean SUVmax was 6.9 ± 5.6 in benign group, 12.7 ± 6.1 in malignant group. Mean TLG values of malignant group and benign group were 401 and 148, respectively. 18 F-FDG-PET/CT was truely positive in 48% of patients with normal Ca 19-9 or CEA levels and truely negative in 10% of cases with elevated Ca 19-9 or CEA. CT or MRI detected suspicious malignancy in 32% of the patients and 18 F-FDG-PET/CT was truely negative in 35% of these cases. We found the most important and striking statistical difference of TLG value between the groups with benign and recurrent disease. Although SUVmax is a strong metabolic parameter (p = 0.008), TLG seems to be the best predictor in recurrence of CRC (p = 0.001); both are increasing the specificity of 18 F-FDG-PET/CT.

  11. High-Resolution Three-Dimensional Computed Tomography for Assessing Complications Related to Intrathecal Drug Delivery.

    PubMed

    Morgalla, Matthias; Fortunato, Marcos; Azam, Ala; Tatagiba, Marcos; Lepski, Guillherme

    2016-07-01

    The assessment of the functionality of intrathecal drug delivery (IDD) systems remains difficult and time-consuming. Catheter-related problems are still very common, and sometimes difficult to diagnose. The aim of the present study is to investigate the accuracy of high-resolution three-dimensional computed tomography (CT) in order to detect catheter-related pump dysfunction. An observational, retrospective investigation. Academic medical center in Germany. We used high-resolution three dimensional (3D) computed tomography with volume rendering technique (VRT) or fluoroscopy and conventional axial-CT to assess IDD-related complications in 51 patients from our institution who had IDD systems implanted for the treatment of chronic pain or spasticity. Twelve patients (23.5%) presented a total of 22 complications. The main type of complication in our series was catheter-related (50%), followed by pump failure, infection, and inappropriate refilling. Fluoroscopy and conventional CT were used in 12 cases. High-resolution 3D CT VRT scan was used in 35 instances with suspected yet unclear complications. Using 3D-CT (VRT) the sensitivity was 58.93% - 100% (CI 95%) and the specificity 87.54% - 100% (CI 95%).The positive predictive value was 58.93% - 100% (CI 95%) and the negative predictive value: 87.54% - 100% (CI 95%).Fluoroscopy and axial CT as a combined diagnostic tool had a sensitivity of 8.3% - 91.7% (CI 95%) and a specificity of 62.9% - 100% (CI 95%). The positive predictive value was 19.29% - 100% (CI 95%) and the negative predictive value: 44.43% - 96.89% (CI 95%). This study is limited by its observational design and the small number of cases. High-resolution 3D CT VRT is a non- invasive method that can identify IDD-related complications with more precision than axial CT and fluoroscopy.

  12. SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, M; Foster, R; Parks, H

    Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-simmore » and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between the plans on CT-sim with assigned CT-number and the deformable SEMAR CT datasets.« less

  13. Low-dose head computed tomography in children: a single institutional experience in pediatric radiation risk reduction: clinical article.

    PubMed

    Morton, Ryan P; Reynolds, Renee M; Ramakrishna, Rohan; Levitt, Michael R; Hopper, Richard A; Lee, Amy; Browd, Samuel R

    2013-10-01

    In this study, the authors describe their experience with a low-dose head CT protocol for a preselected neurosurgical population at a dedicated pediatric hospital (Seattle Children's Hospital), the largest number of patients with this protocol reported to date. All low-dose head CT scans between October 2011 and November 2012 were reviewed. Two different low-dose radiation dosages were used, at one-half or one-quarter the dose of a standard head CT scan, based on patient characteristics agreed upon by the neurosurgery and radiology departments. Patient information was also recorded, including diagnosis and indication for CT scan. Six hundred twenty-four low-dose head CT procedures were performed within the 12-month study period. Although indications for the CT scans varied, the most common reason was to evaluate the ventricles and catheter placement in hydrocephalic patients with shunts (70%), followed by postoperative craniosynostosis imaging (12%). These scans provided adequate diagnostic imaging, and no patient required a follow-up full-dose CT scan as a result of poor image quality on a low-dose CT scan. Overall physician comfort and satisfaction with interpretation of the images was high. An additional 2150 full-dose head CT scans were performed during the same 12-month time period, making the total number of CT scans 2774. This value compares to 3730 full-dose head CT scans obtained during the year prior to the study when low-dose CT and rapid-sequence MRI was not a reliable option at Seattle Children's Hospital. Thus, over a 1-year period, 22% of the total CT scans were able to be converted to low-dose scans, and full-dose CT scans were able to be reduced by 42%. The implementation of a low-dose head CT protocol substantially reduced the amount of ionizing radiation exposure in a preselected population of pediatric neurosurgical patients. Image quality and diagnostic utility were not significantly compromised.

  14. Research on radiation exposure from CT part of hybrid camera and diagnostic CT

    NASA Astrophysics Data System (ADS)

    Solný, Pavel; Zimák, Jaroslav

    2014-11-01

    Research on radiation exposure from CT part of hybrid camera in seven different Departments of Nuclear Medicine (DNM) was conducted. Processed data and effective dose (E) estimations led to the idea of phantom verification and comparison of absorbed doses and software estimation. Anonymous data from about 100 examinations from each DNM was gathered. Acquired data was processed and utilized by dose estimation programs (ExPACT, ImPACT, ImpactDose) with respect to the type of examination and examination procedures. Individual effective doses were calculated using enlisted programs. Preserving the same procedure in dose estimation process allows us to compare the resulting E. Some differences and disproportions during dose estimation led to the idea of estimated E verification. Consequently, two different sets of about 100 of TLD 100H detectors were calibrated for measurement inside the Aldersnon RANDO Anthropomorphic Phantom. Standard examination protocols were examined using a 2 Slice CT- part of hybrid SPECT/CT. Moreover, phantom exposure from body examining protocol for 32 Slice and 64 Slice diagnostic CT scanner was also verified. Absorbed dose (DT,R) measured using TLD detectors was compared with software estimation of equivalent dose HT values, computed by E estimation software. Though, only limited number of cavities for detectors enabled measurement within the regions of lung, liver, thyroid and spleen-pancreas region, some basic comparison is possible.

  15. Diagnostic Value of Software-Based Image Fusion of Computed Tomography and F18-FDG PET Scans in Patients with Malignant Lymphoma

    PubMed Central

    Henninger, B.; Putzer, D.; Kendler, D.; Uprimny, C.; Virgolini, I.; Gunsilius, E.; Bale, R.

    2012-01-01

    Aim. The purpose of this study was to evaluate the accuracy of 2-deoxy-2-[fluorine-18]fluoro-D-glucose (FDG) positron emission tomography (PET), computed tomography (CT), and software-based image fusion of both modalities in the imaging of non-Hodgkin's lymphoma (NHL) and Hodgkin's disease (HD). Methods. 77 patients with NHL (n = 58) or HD (n = 19) underwent a FDG PET scan, a contrast-enhanced CT, and a subsequent digital image fusion during initial staging or followup. 109 examinations of each modality were evaluated and compared to each other. Conventional staging procedures, other imaging techniques, laboratory screening, and follow-up data constituted the reference standard for comparison with image fusion. Sensitivity and specificity were calculated for CT and PET separately. Results. Sensitivity and specificity for detecting malignant lymphoma were 90% and 76% for CT and 94% and 91% for PET, respectively. A lymph node region-based analysis (comprising 14 defined anatomical regions) revealed a sensitivity of 81% and a specificity of 97% for CT and 96% and 99% for FDG PET, respectively. Only three of 109 image fusion findings needed further evaluation (false positive). Conclusion. Digital fusion of PET and CT improves the accuracy of staging, restaging, and therapy monitoring in patients with malignant lymphoma and may reduce the need for invasive diagnostic procedures. PMID:22654631

  16. Value of a Lower-Limb Immobilization Device for Optimization of SPECT/CT Image Fusion.

    PubMed

    Machado, Joana do Mar F; Monteiro, Marina S; Vieira, Victor Fernandes; Collinot, Jean-Aybert; Prior, John O; Vieira, Lina; Pires-Jorge, José A

    2015-06-01

    The foot and the ankle are small structures commonly affected by disorders, and their complex anatomy represents a significant diagnostic challenge. By providing information on anatomic and bone structure that cannot be obtained from functional imaging, SPECT/CT image fusion can be particularly useful in increasing diagnostic certainty about bone pathology. However, because of the lengthy duration of a SPECT acquisition, a patient's involuntary movements may lead to misalignment between SPECT and CT images. Patient motion can be reduced using a dedicated patient support. We designed an ankle- and foot-immobilizing device and measured its efficacy at improving image fusion. We enrolled 20 patients who underwent SPECT/CT of the ankle and foot with and without a foot support. The misalignment between SPECT and CT images was computed by manually measuring 14 fiducial markers chosen among anatomic landmarks also visible on bone scintigraphy. ANOVA was performed for statistical analysis. The absolute average difference without and with support was 5.1 ± 5.2 mm (mean ± SD) and 3.1 ± 2.7 mm, respectively, which is significant (P < 0.001). The introduction of the foot support significantly decreased misalignment between SPECT and CT images, which may have a positive clinical influence in the precise localization of foot and ankle pathology. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  17. [Significance of PSMA imaging in prostate cancer].

    PubMed

    Gasch, C; Düwel, C; Kopka, K; Kratochwil, C; Vinsensia, M; Eiber, M; Maurer, T; Haberkorn, U; Hadaschik, B; Giesel, F L

    2017-01-01

    Prostate cancer (PCa) is one of the most common malignancies of men in developed countries. To improve clinical diagnostics of PCa, 68 Ga-PSMA-11 was recently introduced as a new PET tracer. 68 Ga-PSMA-11 is able to specifically bind to the prostate-specific membrane antigen (PSMA), which is upregulated on the surface of prostate cancer cells in most patients. To analyse the current significance of 68 Ga-PSMA-11 PET imaging in prostate cancer in relation to staging of men with initial diagnosis, biochemical recurrence and metastatic disease. Retrospective analysis of current literature (PubMed search) regarding 68 Ga-PSMA-11 PET diagnostics in primary staging, in biochemical recurrence and in metastasized disease. Compared to conventional imaging, 68 Ga-PSMA-11 PET/CT reaches a higher sensitivity with an excellent specificity in the clinical diagnosis of primary staging as well as staging for recurrence and advanced, metastasized disease. In biochemical recurrence, 68 Ga-PSMA-11 PET/CT shows significantly higher detection rates in comparison to choline PET/CT, especially in patients with low PSA values. In the clinical diagnosis of recurrent disease, therapy concepts were changed in more than a quarter of the patients due to the use of 68 Ga-PSMA-11 PET/CT. The significance of staging with 68 Ga-PSMA-11 PET/CT in advanced metastasized patients remains uncertain. Due to the excellent results of 68 Ga-PSMA-11 PET imaging, even in patients with slightly elevated PSA levels, it will continue to play an important role in clinical diagnostics of prostate cancer and, thus, its clinical utilization will become more widely spread.

  18. Motion correction for improving the accuracy of dual-energy myocardial perfusion CT imaging

    NASA Astrophysics Data System (ADS)

    Pack, Jed D.; Yin, Zhye; Xiong, Guanglei; Mittal, Priya; Dunham, Simon; Elmore, Kimberly; Edic, Peter M.; Min, James K.

    2016-03-01

    Coronary Artery Disease (CAD) is the leading cause of death globally [1]. Modern cardiac computed tomography angiography (CCTA) is highly effective at identifying and assessing coronary blockages associated with CAD. The diagnostic value of this anatomical information can be substantially increased in combination with a non-invasive, low-dose, correlative, quantitative measure of blood supply to the myocardium. While CT perfusion has shown promise of providing such indications of ischemia, artifacts due to motion, beam hardening, and other factors confound clinical findings and can limit quantitative accuracy. In this paper, we investigate the impact of applying a novel motion correction algorithm to correct for motion in the myocardium. This motion compensation algorithm (originally designed to correct for the motion of the coronary arteries in order to improve CCTA images) has been shown to provide substantial improvements in both overall image quality and diagnostic accuracy of CCTA. We have adapted this technique for application beyond the coronary arteries and present an assessment of its impact on image quality and quantitative accuracy within the context of dual-energy CT perfusion imaging. We conclude that motion correction is a promising technique that can help foster the routine clinical use of dual-energy CT perfusion. When combined, the anatomical information of CCTA and the hemodynamic information from dual-energy CT perfusion should facilitate better clinical decisions about which patients would benefit from treatments such as stent placement, drug therapy, or surgery and help other patients avoid the risks and costs associated with unnecessary, invasive, diagnostic coronary angiography procedures.

  19. 18F-FDG PET-CT after Neoadjuvant Chemoradiotherapy in Esophageal Cancer Patients to Optimize Surgical Decision Making

    PubMed Central

    Anderegg, Maarten C. J.; de Groof, Elisabeth J.; Gisbertz, Suzanne S.; Bennink, Roel J.; Lagarde, Sjoerd M.; Klinkenbijl, Jean H. G.; Dijkgraaf, Marcel G. W.; Bergman, Jacques J. G. H. M.; Hulshof, Maarten C. C. M.; van Laarhoven, Hanneke W. M.; van Berge Henegouwen, Mark I.

    2015-01-01

    Background Prognosis of esophageal cancer patients can be significantly improved by neoadjuvant chemoradiotherapy (nCRT). Given the aggressive nature of esophageal tumors, it is conceivable that in a significant portion of patients treated with nCRT, dissemination already becomes manifest during the period of nCRT. The aim of this retrospective study was to determine the value and diagnostic accuracy of PET-CT after neoadjuvant chemoradiotherapy to identify patients with metastases preoperatively in order to prevent non-curative surgery. Methods From January 2011 until February 2013 esophageal cancer patients deemed eligible for a curative approach with nCRT and surgical resection underwent a PET-CT after completion of nCRT. If abnormalities on PET-CT were suspected metastases, histological proof was acquired. A clinical decision model was designed to assess the cost-effectiveness of this diagnostic strategy. Results 156 patients underwent a PET-CT after nCRT. In 31 patients (19.9%) PET-CT showed abnormalities suspicious for dissemination, resulting in 17 cases of proven metastases (10.9%). Of the patients without proven metastases 133 patients were operated. In 6 of these 133 cases distant metastases were detected intraoperatively, corresponding to 4.5% false-negative results. The standard introduction of a post-neoadjuvant therapy PET-CT led to a reduction of overall health care costs per patient compared to a scenario without restaging with PET-CT ($34,088 vs. $36,490). Conclusion In 10.9% of esophageal cancer patients distant metastases were detected by standard PET-CT after neoadjuvant chemoradiotherapy. To avoid non-curative resections we advocate post-neoadjuvant therapy PET-CT as a cost-effective step in the standard work-up of candidates for surgery. PMID:26529313

  20. Comparison of diagnostic performance between single- and multiphasic contrast-enhanced abdominopelvic computed tomography in patients admitted to the emergency department with abdominal pain: potential radiation dose reduction.

    PubMed

    Hwang, Shin Hye; You, Je Sung; Song, Mi Kyong; Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun

    2015-04-01

    To evaluate feasibility of radiation dose reduction by optimal phase selection of computed tomography (CT) in patients who visited the emergency department (ED) for abdominal pain. We included 253 patients who visited the ED for abdominal pain. They underwent multiphasic CT including precontrast, late arterial phase (LAP), and hepatic venous phase (HVP). Three image sets (HVP, precontrast + HVP, and precontrast + LAP + HVP) were reviewed. Two reviewers determined the most appropriate diagnosis with five-point confidence scale. Diagnostic performances were compared among image sets by weighted-least-squares method or DeLong's method. Linear mixed model was used to assess changes of diagnostic confidence and radiation dose. There was no difference in diagnostic performance among three image sets, although diagnostic confidence level was significantly improved after review of triphasic images compared with both HVP images only or HVP with precontrast images (confidence scale, 4.64 ± 0.05, 4.66 ± 0.05, and 4.76 ± 0.04 in the order of the sets; overall P = 0.0008). Similar trends were observed in the subgroup analysis for diagnosis of pelvic inflammatory disease and cholecystitis. There is no difference between HVP-CT alone and multiphasic CT for the diagnosis of causes of abdominal pain in patients admitted to the ED without prior chronic disease or neoplasia. • There was no difference in diagnostic performance of HVP CT and multiphasic CT. • The diagnostic confidence level was improved after review of the LAP images. • HVP CT can achieve diagnostic performance similar to that of multiphasic CT, while minimizing radiation.

  1. Diagnostic and prognostic value of additional SPECT/CT in sentinel lymph node mapping in breast cancer patients.

    PubMed

    Stanzel, Susanne; Pernthaler, Birgit; Schwarz, Thomas; Bjelic-Radisic, Vesna; Kerschbaumer, Stefan; Aigner, Reingard M

    2018-06-01

    of the study was to demonstrate the diagnostic and prognostic value of SPECT/CT in sentinel lymph node mapping (SLNM) in patients with invasive breast cancer. 114 patients with invasive breast cancer with clinically negative lymph nodes were included in this retrospective study as they were referred for SLNM with 99m Tc-nanocolloid. Planar image acquisition was accomplished in a one-day or two-day protocol depending on the schedule of the surgical procedure. Low dose SPECT/CT was performed after the planar images. The sentinel lymph node biopsy (SLNB) was considered false negative if a primary recurrence developed within 12 months after SLNB in the axilla from which a tumor-free SLN had been removed. Between December 2009 and December 2011, 114 patients (pts.) underwent SLNM with additional SPECT/CT. Planar imaging identified in 109 pts. 139 SLNs, which were tumor-positive in 42 nodes (n = 41 pts.). SPECT/CT identified in 81 pts. 151 additional SLNs, of which 19 were tumor-positive and led to therapy change (axillary lymph node dissection) in 11 pts. (9.6 %). Of overall 61 tumor-positive SLNs (n = 52 pts.) SPECT/CT detected all, whereas planar imaging detected only 42 of 61 ( P < 0.0001). No patient had lymph node metastasis within 12 months after SLNB in the axilla from which a tumor-free SLN had been removed resulting in a false-negative rate of 0 %. The local relapse rate was 1.8 % leading to a 4-year disease-free survival rate of 90 %. Among patients with breast cancer, the use of SPECT/CT-aided SLNM correlated due to a better anatomical localization and identification of planar not visible SLNs with a higher detection rate of SLNs. This led to therapeutic consequences and an excellent false-negative and 4-year disease-free survival rate. Schattauer GmbH.

  2. Diagnostic Ability of FDG-PET/CT in the Detection of Malignant Pleural Effusion.

    PubMed

    Nakajima, Reiko; Abe, Koichiro; Sakai, Shuji

    2015-07-01

    We investigated the role of F-18 fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) for the differential diagnosis of malignant and benign pleural effusion. We studied 36 consecutive patients with histologically proven cancer (excluding malignant mesothelioma) who underwent FDG-PET/CT for suspected malignant pleural effusion. Fourteen patients had cytologically proven malignant pleural effusion and the other 22 patients had either negative cytology or clinical follow-up, which confirmed the benign etiology. We examined the maximum standardized uptake values (SUV max) of pleural effusion and the target-to-normal tissue ratio (TNR), calculated as the ratio of the pleural effusion SUV max to the SUV mean of the normal tissues (liver, spleen, 12th thoracic vertebrae [Th12], thoracic aorta, and spinalis muscle). We also examined the size and density (in Hounsfield units) of the pleural effusion and pleural abnormalities on CT images. TNR (Th12) and increased pleural FDG uptake compared to background blood pool were significantly more frequent in cases with malignant pleural effusion (P < 0.05 for both). The cutoff TNR (Th12) value of >0.95 was the most accurate; the sensitivity, specificity, and accuracy for this value were 93%, 68%, and 75%, respectively. FDG-PET/CT can be a useful method for the differential diagnosis of malignant and benign pleural effusion.

  3. Complications in CT-guided procedures: do we really need postinterventional CT control scans?

    PubMed

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-02-01

    The aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans. Retrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only. The complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21). Complications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  4. Angiotensin-converting Enzyme as a Predictor of Extrathoracic Involvement of Sarcoidosis.

    PubMed

    Yasar, Zehra; Özgül, Mehmet Akif; Cetinkaya, Erdoğan; Kargi, Aysel; Gül, Şule; Talay, Fahrettin; Tanriverdi, Elif; Dincer, H Erhan

    2016-01-18

    Sarcoidosis is a multisystem disease, with extrathoracic involvement occurring in 25-50% of patients. Multi-organ involvement is often associated with a more chronic and severe course. The value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in diagnosing extrathoracic involvement in sarcoidosis has been demonstrated; however, because of the radiation dose and high cost, indications for its use must be well defined. Angiotensin-converting enzyme (ACE) is produced by active granuloma cells; thus, serum ACE (sACE) levels may reflect the total granuloma load. In this retrospective study, we evaluated the diagnostic value of sACE in the detection of extrathoracic involvement in sarcoidosis. 43 patients with biopsy-proven sarcoidosis underwent FDG-PET/CT during the initial workup. Positive findings were classified as thoracic and/or extrathoracic. The diagnostic value of sACE was estimated using sensitivity, specificity, and area under the receiver operating characteristic curves (AUCs). Of the 43 patients studied, 17 (39.7%) had extrathoracic involvement. In this group, sACE values were higher than in patients without extrathoracic involvement (331 vs. 150, p=0.002) and correlated positively with extrathoracic involvement (R:0.532 p=0.02). Receiver operator characteristic curve analysis revealed an AUC of 0.816 [95% confidence interval: 0.669-0.963, p=0.002], 70.6% sensitivity and 80% specificity at the sACE cut-off value. In sarcoidosis, extrathoracic involvement may be life threatening or indicative of poor outcome. sACE levels are easily determined and may predict extrathoracic involvement. In patients with sarcoidosis, sACE levels can be used to better define those who would benefit from FDG-PET/CT examination to detect extrathoracic involvement.

  5. CT imaging, then and now: a 30-year review of the economics of computed tomography.

    PubMed

    Stockburger, Wayne T

    2004-01-01

    The first computed tomography (CT) scanner in the US was installed in June 1973 at the Mayo Clinic in Rochester, MN. By the end of 1974, 44 similar systems had been installed at medical facilities around the country. Less than 4 years after the introduction of CT imaging in the US, at least 400 CT systems had been installed. The practice of pneumoencephalography was eliminated. The use of nuclear medicine brain scans significantly diminished. At the time, CT imaging was limited to head studies, but with the introduction of contrast agents and full body CT systems the changes in the practice of medicine became even more significant. CT imaging was hailed by the US medical community as the greatest advance in radiology since the discovery of x-rays. But the rapid spread of CT systems, their frequency of use, and the associated increase in healthcare costs combined to draw the attention of decision-makers within the federal and state governments, specifically to establish policies regarding the acquisition and use of diagnostic technologies. Initially, CT imaging was limited to neurological applications, but in the 30 years since its inception, capabilities and applications have been expanded as a result of the advancements in technology and software development. While neurological disorders are still a common reason for CT imaging, many other medical disciplines (oncology, emergency medicine, orthopedics, etc.) have found CT imaging to be the definitive tool for diagnostic information. As such, the clinical demand for CT imaging has steadily increased. Economically, the development of CT imaging has been one of success, even in the face of governmental action to restrict its acquisition and utilization by healthcare facilities. CTimaging has increased the cost of healthcare, but in turn has added unquantifiable value to the practice of medicine in the US.

  6. Comparison of 68Ga-PSMA-11 PET-CT with mpMRI for preoperative lymph node staging in patients with intermediate to high-risk prostate cancer.

    PubMed

    Zhang, Qing; Zang, Shiming; Zhang, Chengwei; Fu, Yao; Lv, Xiaoyu; Zhang, Qinglei; Deng, Yongming; Zhang, Chuan; Luo, Rui; Zhao, Xiaozhi; Wang, Wei; Wang, Feng; Guo, Hongqian

    2017-11-07

    To evaluate the diagnostic value of 68 Ga-PSMA-11 PET-CT with multiparametric magnetic resonance imaging (mpMRI) for lymph node (LN) staging in patients with intermediate- to high-risk prostate cancer (PCa) undergoing radical prostatectomy (RP) with pelvic lymph node dissection (PLND). We retrospectively identified 42 consecutive patients with intermediate- to high-risk PCa according to D'Amico and without concomitant cancer. Preoperative 68 Ga-PSMA-11 PET-CT, pelvic mpMRI and subsequent robot assisted laparoscopic RP with PLND were performed in all patients. Among 42 patients assessed, the preoperative PSA value, Gleason score, pT stage and intraprostatic PCa volume of patients with LN metastases were all significantly higher than those without metastases (P = 0.029, 0.028, 0.004, respectively). The average maximum standardized uptake value (SUV) of 68 Ga-PSMA-11 PET-CT positive PCa of patients with or without LN metastases were 13.10 (range 6.12-51.75) and 7.22 (range 5.4-11.2), respectively (P < 0.001). 68 Ga-PSMA-11 PET-CT and pelvic mpMRI had the ability of succeed on preoperative definite accurate diagnosis and accurate localization of primary PCa in all 42 patients. Fifteen patients (35.71%) had a pN1 stage. 51 positive LN were found. Both 68 Ga-PSMA-11 PET-CT and pelvic mpMRI displayed brillient patient-based and region-based sensitivity, specificity, negative predictive value and positive predictive value. There was no statistical difference for the detection of LNMs according to the diameter of the LNMs between 68 Ga-PSMA-11 PET-CT and mpMRI in this study. Both 68 Ga-PSMA-11 PET-CT and mpMRI performed great value for LN staging in patients with intermediate- to high-risk PCa undergoing RP with PLND. However, despite excellent performance of 68 Ga-PSMA-11 PET-CT, it cannot replace mpMRI that remains excellent for lymph node staging.

  7. Latent class analysis of the diagnostic characteristics of PCR and conventional bacteriological culture in diagnosing intramammary infections caused by Staphylococcus aureus in dairy cows at dry off

    PubMed Central

    2012-01-01

    Background Staphylococcus aureus is one of the most common causes of intramammary infections in dairy cows at dry off. Reliable identification is important for disease management on herd level and for antimicrobial treatment of infected animals. Our objective was to evaluate the test characteristics of PathoProof ™ Mastitis PCR Assay and bacteriological culture (BC) in diagnosing bovine intramammary infections caused by S. aureus at dry off at different PCR cycle threshold (Ct)-value cut-offs. Methods Sterile quarter samples and non-sterile composite samples from 140 animals in seven herds were collected in connection with the dairy herd improvement (DHI) milk recording. All quarter samples were analyzed using BC whereas all composite samples were analyzed with PathoProof ™ Mastitis PCR Assay. Latent class analysis was used to estimate test properties for PCR and BC in the absence of a perfect reference test. The population was divided into two geographically divided subpopulations and the Hui-Walter 2-test 2-populations model applied to estimate Se, Sp for the two tests, and prevalence for the two subpopulations. Results The Se for PCR increased with increasing Ct-value cut-off, accompanied by a small decrease in Sp. For BC the Se decreased and Sp increased with increasing Ct-value cut-off. Most optimal test estimates for the real-time PCR assay were at a Ct-value cut-off of 37; 0.93 [95% posterior probability interval (PPI) 0.60-0.99] for Se and 0.95 [95% PPI 0.95-0.99] for Sp. At the same Ct-value cut-off, Se and Sp for BC were 0.83 [95% PPI 0.66-0.99] and 0.97 [95% PPI 0.91-0.99] respectively. Depending on the chosen PCR Ct-value cut-off, the prevalence in the subpopulations varied; the prevalence increased with increasing PCR Ct-value cut-offs. Conclusion Neither BC nor real-time PCR is a perfect test in detecting IMI in dairy cows at dry off. The changes in sensitivity and prevalence at different Ct-value cut-offs for both PCR and BC may indicate a change in the underlying disease definition. At low PCR Ct-value cut-offs the underlying disease definition may be a truly/heavily infected cow, whereas at higher PCR Ct-value cut-offs the disease definition may be a S. aureus positive cow. PMID:23164432

  8. Diagnostic performance of a computer-assisted diagnosis system for bone scintigraphy of newly developed skeletal metastasis in prostate cancer patients: search for low-sensitivity subgroups.

    PubMed

    Koizumi, Mitsuru; Motegi, Kazuki; Koyama, Masamichi; Terauchi, Takashi; Yuasa, Takeshi; Yonese, Junji

    2017-08-01

    The computer-assisted diagnostic system for bone scintigraphy (BS) BONENAVI is used to evaluate skeletal metastasis. We investigated its diagnostic performance in prostate cancer patients with and without skeletal metastasis and searched for the problems. An artificial neural network (ANN) value was calculated in 226 prostate cancer patients (124 with skeletal metastasis and 101 without) using BS. Receiver operating characteristic curve analysis was performed and the sensitivity and specificity determined (cutoff ANN = 0.5). Patient's situation at the time of diagnosis of skeletal metastasis, computed tomography (CT) type, extent of disease (EOD), and BS uptake grade were analyzed. False-negative and false-positive results were recorded. BONENAVI showed 82% (102/124) of sensitivity and 83% (84/101) specificity for metastasis detection. There were no significant differences among CT types, although low EOD and faint BS uptake were associated with low ANN values and low sensitivity. Patients showed lower sensitivity during the follow-up period than staging work-up. False-negative lesions were often located in the pelvis or adjacent to it. They comprised not only solitary, faint BS lesions but also overlaying to urinary excretion. BONENAVI with BS has good sensitivity and specificity for detecting prostate cancer's osseous metastasis. Low EOD and faint BS uptake are associated with low sensitivity but not the CT type. Prostate cancer patients likely to have false-negative results during the follow-up period had a solitary lesion in the pelvis with faint BS uptake or lesions overlaying to urinary excretion.

  9. Dual time point 2-deoxy-2-[18F]fluoro-D-glucose PET/CT: nodal staging in locally advanced breast cancer.

    PubMed

    García Vicente, A M; Soriano Castrejón, A; Cruz Mora, M Á; Ortega Ruiperez, C; Espinosa Aunión, R; León Martín, A; González Ageitos, A; Van Gómez López, O

    2014-01-01

    To assess dual time point 2-deoxy-2-[(18)F]fluoro-D-glucose (18)(F)FDG PET-CT accuracy in nodal staging and in detection of extra-axillary involvement. Dual time point [(18)F] FDG PET/CT scan was performed in 75 patients. Visual and semiquantitative assessment of lymph nodes was performed. Semiquantitative measurement of SUV and ROC-analysis were carried out to calculate SUV(max) cut-off value with the best diagnostic performance. Axillary and extra-axillary lymph node chains were evaluated. Sensitivity and specificity of visual assessment was 87.3% and 75%, respectively. SUV(max) values with the best sensitivity were 0.90 and 0.95 for early and delayed PET, respectively. SUV(max) values with the best specificity were 1.95 and 2.75, respectively. Extra-axillary lymph node involvement was detected in 26.7%. FDG PET/CT detected extra-axillary lymph node involvement in one-fourth of the patients. Semiquantitative lymph node analysis did not show any advantage over the visual evaluation. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  10. Diagnostic Value of Transthoracic Echocardiography in Patients With Anomalous Origin of the Left Coronary Artery From the Pulmonary Artery

    PubMed Central

    Li, Rong-Juan; Sun, Zhonghua; Yang, Jiao; Yang, Ya; Li, Yi-Jia; Leng, Zhao-Ting; Liu, Guo-Wen; Pu, Li-Hong

    2016-01-01

    Abstract Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital coronary abnormality associated with early infant mortality and sudden death in adults. Transthoracic echocardiography (TTE) plays an important role in early detection and diagnosis of ALCAPA as a noninvasive modality. However, its diagnostic value is not well studied. The purpose of this study is to determine the performance of TTE in the diagnostic assessment of ALCAPA as compared with coronary CT and invasive coronary angiography. A total of 22 patients (13 women and 9 men, mean age, 12.9 ± 19.5 years) with ALCAPA who underwent echocardiographic examination for clinical diagnosis were retrospectively reviewed and analyzed. Transthoracic echocardiographic features of ALCAPA were analyzed and its diagnostic value was compared with invasive coronary angiography and coronary CT angiography (CTA) with surgical findings serving as the gold standard. Surgery was performed in all of the patients to establish the dual coronary artery system. Five underwent the Takeuchi procedure and 17 had re-implantation of the anomalous left coronary artery. Of 20 patients, echocardiographic diagnoses were in good agreement with findings at surgery, resulting in the diagnostic accuracy of 90.9%. Two cases were misdiagnosed—one as the right coronary artery to pulmonary artery fistula and the other as rheumatic heart disease. The echocardiographic features of these patients with ALCAPA included: abnormal left coronary ostium arising from the pulmonary trunk with retrograde coronary artery flow in 20 patients; enlargement of the right coronary artery in 17 patients; abundant intercoronary septal collaterals in 17 patients; and moderate and significant mitral regurgitation in 14 patients. The diagnostic accuracy of invasive coronary angiography (in 17 patients) and coronary CTA (in 9 patients) was 100%. This study shows that TTE is an accurate, noninvasive imaging modality for displaying the origin of coronary arteries and demonstrating the coronary courses as well as other associated abnormalities in patients with ALCAPA. PMID:27082616

  11. Diagnostic accuracy for macroscopic classification of nodular hepatocellular carcinoma: comparison of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging and angiography-assisted computed tomography.

    PubMed

    Tada, Toshifumi; Kumada, Takashi; Toyoda, Hidenori; Ito, Takanori; Sone, Yasuhiro; Okuda, Seiji; Ogawa, Sadanobu; Igura, Takumi; Imai, Yasuharu

    2015-01-01

    The macroscopic type of hepatocellular carcinoma (HCC) is a predictor of prognosis. We clarified the diagnostic value of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) in the macroscopic classification of nodular hepatocellular carcinoma (HCC) as compared to angiography-assisted computed tomography (CT). A total of 71 surgically resected nodular HCCs with a maximum diameter of ≤5 cm were investigated. HCCs were evaluated preoperatively using Gd-EOB-DTPA-enhanced MRI and angiography-assisted CT. HCCs were pathologically classified as simple nodular (SN), SN with extranodular growth (SN-EG), or confluent multinodular (CMN). SN-EG and CMN were grouped as non-SN. Five readers independently reviewed the images using a five-point scale. We examined the accuracy of both imaging modalities in differentiating between SN and non-SN HCC. Overall, the area under the receiver operating characteristic curve (A z ) for the diagnosis of non-SN did not differ between Gd-EOB-DTPA-enhanced MRI and angiography-assisted CT [0.879 (95% confidence interval (CI), 0.779-0.937) and 0.845 (95% CI, 0.723-0.919), respectively]. For HCCs >2 cm, the A z for Gd-EOB-DTPA-enhanced MRI was greater than 0.9. The sensitivity, specificity, and accuracy of Gd-EOB-DTPA-enhanced MRI for identifying non-SN were equal to or higher than values with angiography-assisted CT in all three categories (all tumors, ≤2 cm, and >2 cm), but the differences were not statistically significant. Using Gd-EOB-DTPA-enhanced MRI to assess the macroscopic findings in nodular HCC was equal or superior to using angiography-assisted CT.

  12. Diagnostic importance of contrast enhanced 18F-fluorodeoxyglucose positron emission computed tomography in patients with tumor induced osteomalacia: Our experience

    PubMed Central

    Jain, Avani S.; Shelley, Simon; Muthukrishnan, Indirani; Kalal, Shilpa; Amalachandran, Jaykanth; Chandran, Sureshkumar

    2016-01-01

    Aims and Objectives: To assess the diagnostic utility of contrast-enhanced 18F-fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET-ceCT) in localization of tumors in patients with clinical diagnosis of tumor-induced osteomalacia (TIO), in correlation with histopathological results. Materials and Methods: Eight patients (five male and three female) aged 24–60 (mean 42) years with a clinical diagnosis of TIO were included in this prospective study. They underwent whole body (head to toe) FDG PET-ceCT following a standard protocol on Philips GEMINI TF PET-CT scanner. The FDG PET-ceCT results were correlated with postoperative histology findings and clinical follow-up. Results: All the patients had an abnormal PET-ceCT study. The sensitivity of PET-ceCT was 87.5%, and positive predictive value was 100%. The tumor was located in the craniofacial region in 6/8 patients and in bone in 2/8 patients. Hemangiopericytoma was the most common reported histology. All patients underwent surgery, following which they demonstrated clinical improvement. However, one patient with atypical findings on histology did not show any clinical improvement, hence, underwent 68Gallium-DOTANOC PET-ceCT scan for relocalization of the site of the tumor. Conclusion: The tumors causing TIO are small in size and usually located in obscure sites in the body. Hence, head to toe protocol should be followed for FDG PET-ceCT scans with the inclusion of upper limbs. Once the tumor is localized, regional magnetic resonance imaging can be performed for better characterization of soft tissue lesion. Imaging with FDG PET-ceCT plays an important role in detecting the site of the tumor and thereby facilitating timely management. PMID:26917888

  13. Diagnostic importance of contrast enhanced (18)F-fluorodeoxyglucose positron emission computed tomography in patients with tumor induced osteomalacia: Our experience.

    PubMed

    Jain, Avani S; Shelley, Simon; Muthukrishnan, Indirani; Kalal, Shilpa; Amalachandran, Jaykanth; Chandran, Sureshkumar

    2016-01-01

    To assess the diagnostic utility of contrast-enhanced (18)F-fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET-ceCT) in localization of tumors in patients with clinical diagnosis of tumor-induced osteomalacia (TIO), in correlation with histopathological results. Eight patients (five male and three female) aged 24-60 (mean 42) years with a clinical diagnosis of TIO were included in this prospective study. They underwent whole body (head to toe) FDG PET-ceCT following a standard protocol on Philips GEMINI TF PET-CT scanner. The FDG PET-ceCT results were correlated with postoperative histology findings and clinical follow-up. All the patients had an abnormal PET-ceCT study. The sensitivity of PET-ceCT was 87.5%, and positive predictive value was 100%. The tumor was located in the craniofacial region in 6/8 patients and in bone in 2/8 patients. Hemangiopericytoma was the most common reported histology. All patients underwent surgery, following which they demonstrated clinical improvement. However, one patient with atypical findings on histology did not show any clinical improvement, hence, underwent (68)Gallium-DOTANOC PET-ceCT scan for relocalization of the site of the tumor. The tumors causing TIO are small in size and usually located in obscure sites in the body. Hence, head to toe protocol should be followed for FDG PET-ceCT scans with the inclusion of upper limbs. Once the tumor is localized, regional magnetic resonance imaging can be performed for better characterization of soft tissue lesion. Imaging with FDG PET-ceCT plays an important role in detecting the site of the tumor and thereby facilitating timely management.

  14. Added value of cost-utility analysis in simple diagnostic studies of accuracy: (18)F-fluoromethylcholine PET/CT in prostate cancer staging.

    PubMed

    Gerke, Oke; Poulsen, Mads H; Høilund-Carlsen, Poul Flemming

    2015-01-01

    Diagnostic studies of accuracy targeting sensitivity and specificity are commonly done in a paired design in which all modalities are applied in each patient, whereas cost-effectiveness and cost-utility analyses are usually assessed either directly alongside to or indirectly by means of stochastic modeling based on larger randomized controlled trials (RCTs). However the conduct of RCTs is hampered in an environment such as ours, in which technology is rapidly evolving. As such, there is a relatively limited number of RCTs. Therefore, we investigated as to which extent paired diagnostic studies of accuracy can be also used to shed light on economic implications when considering a new diagnostic test. We propose a simple decision tree model-based cost-utility analysis of a diagnostic test when compared to the current standard procedure and exemplify this approach with published data from lymph node staging of prostate cancer. Average procedure costs were taken from the Danish Diagnosis Related Groups Tariff in 2013 and life expectancy was estimated for an ideal 60 year old patient based on prostate cancer stage and prostatectomy or radiation and chemotherapy. Quality-adjusted life-years (QALYs) were deduced from the literature, and an incremental cost-effectiveness ratio (ICER) was used to compare lymph node dissection with respective histopathological examination (reference standard) and (18)F-fluoromethylcholine positron emission tomography/computed tomography (FCH-PET/CT). Lower bounds of sensitivity and specificity of FCH-PET/CT were established at which the replacement of the reference standard by FCH-PET/CT comes with a trade-off between worse effectiveness and lower costs. Compared to the reference standard in a diagnostic accuracy study, any imperfections in accuracy of a diagnostic test imply that replacing the reference standard generates a loss in effectiveness and utility. We conclude that diagnostic studies of accuracy can be put to a more extensive use, over and above a mere indication of sensitivity and specificity of an imaging test, and that health economic considerations should be undertaken when planning a prospective diagnostic accuracy study. These endeavors will prove especially fruitful when comparing several imaging techniques with one another, or the same imaging technique using different tracers, with an independent reference standard for the evaluation of results.

  15. Characterization of Incidental Renal Mass With Dual-Energy CT: Diagnostic Accuracy of Effective Atomic Number Maps for Discriminating Nonenhancing Cysts From Enhancing Masses.

    PubMed

    Mileto, Achille; Allen, Brian C; Pietryga, Jason A; Farjat, Alfredo E; Zarzour, Jessica G; Bellini, Davide; Ebner, Lukas; Morgan, Desiree E

    2017-10-01

    The purpose of this study was to assess the diagnostic accuracy of effective atomic number maps reconstructed from dual-energy contrast-enhanced data for discriminating between nonenhancing renal cysts and enhancing masses. Two hundred six patients (128 men, 78 women; mean age, 64 years) underwent a CT renal mass protocol (single-energy unenhanced and dual-energy contrast-enhanced nephrographic imaging) at two different hospitals. For each set of patients, two blinded, independent observers performed measurements on effective atomic number maps from contrast-enhanced dual-energy data. Renal mass assessment on unenhanced and nephrographic images, corroborated by imaging and medical records, was the reference standard. The diagnostic accuracy of effective atomic number maps was assessed with ROC analysis. Significant differences in mean effective atomic numbers (Z eff ) were observed between nonenhancing and enhancing masses (set A, 8.19 vs 9.59 Z eff ; set B, 8.05 vs 9.19 Z eff ; sets combined, 8.13 vs 9.37 Z eff ) (p < 0.0001). An effective atomic number value of 8.36 Z eff was the optimal threshold, rendering an AUC of 0.92 (95% CI, 0.89-0.94), sensitivity of 90.8% (158/174 [95% CI, 85.5-94.7%]), specificity of 85.2% (445/522 [95% CI, 81.9-88.2%]), and overall diagnostic accuracy of 86.6% (603/696 [95% CI, 83.9-89.1%]). Nonenhancing renal cysts, including hyperattenuating cysts, can be discriminated from enhancing masses on effective atomic number maps generated from dual-energy contrast-enhanced CT data. This technique may be of clinical usefulness when a CT protocol for comprehensive assessment of renal masses is not available.

  16. Impact of iterative metal artifact reduction on diagnostic image quality in patients with dental hardware.

    PubMed

    Weiß, Jakob; Schabel, Christoph; Bongers, Malte; Raupach, Rainer; Clasen, Stephan; Notohamiprodjo, Mike; Nikolaou, Konstantin; Bamberg, Fabian

    2017-03-01

    Background Metal artifacts often impair diagnostic accuracy in computed tomography (CT) imaging. Therefore, effective and workflow implemented metal artifact reduction algorithms are crucial to gain higher diagnostic image quality in patients with metallic hardware. Purpose To assess the clinical performance of a novel iterative metal artifact reduction (iMAR) algorithm for CT in patients with dental fillings. Material and Methods Thirty consecutive patients scheduled for CT imaging and dental fillings were included in the analysis. All patients underwent CT imaging using a second generation dual-source CT scanner (120 kV single-energy; 100/Sn140 kV in dual-energy, 219 mAs, gantry rotation time 0.28-1/s, collimation 0.6 mm) as part of their clinical work-up. Post-processing included standard kernel (B49) and an iterative MAR algorithm. Image quality and diagnostic value were assessed qualitatively (Likert scale) and quantitatively (HU ± SD) by two reviewers independently. Results All 30 patients were included in the analysis, with equal reconstruction times for iMAR and standard reconstruction (17 s ± 0.5 vs. 19 s ± 0.5; P > 0.05). Visual image quality was significantly higher for iMAR as compared with standard reconstruction (3.8 ± 0.5 vs. 2.6 ± 0.5; P < 0.0001, respectively) and showed improved evaluation of adjacent anatomical structures. Similarly, HU-based measurements of degree of artifacts were significantly lower in the iMAR reconstructions as compared with the standard reconstruction (0.9 ± 1.6 vs. -20 ± 47; P < 0.05, respectively). Conclusion The tested iterative, raw-data based reconstruction MAR algorithm allows for a significant reduction of metal artifacts and improved evaluation of adjacent anatomical structures in the head and neck area in patients with dental hardware.

  17. A Prospective Study Comparing 99mTc-Hydroxyethylene-Diphosphonate Planar Bone Scintigraphy and Whole-Body SPECT/CT with 18F-Fluoride PET/CT and 18F-Fluoride PET/MRI for Diagnosing Bone Metastases.

    PubMed

    Löfgren, Johan; Mortensen, Jann; Rasmussen, Sine H; Madsen, Claus; Loft, Annika; Hansen, Adam E; Oturai, Peter; Jensen, Karl Erik; Mørk, Mette Louise; Reichkendler, Michala; Højgaard, Liselotte; Fischer, Barbara M

    2017-11-01

    We prospectively evaluated and compared the diagnostic performance of 99m Tc-hydroxyethylene-diphosphonate ( 99m Tc-HDP) planar bone scintigraphy (pBS), 99m Tc-HDP SPECT/CT, 18 F-NaF PET/CT, and 18 F-NaF PET/MRI for the detection of bone metastases. Methods: One hundred seventeen patients with histologically proven malignancy referred for clinical pBS were prospectively enrolled. pBS and whole-body SPECT/CT were performed followed by 18 F-NaF PET/CT within 9 d. 18 F-NaF PET/MRI was also performed in 46 patients. Results: Bone metastases were confirmed in 16 patients and excluded in 101, which was lower than expected. The number of equivocal scans was significantly higher for pBS than for SPECT/CT and PET/CT (18 vs. 5 and 6, respectively; P = 0.004 and 0.01, respectively). When equivocal readings were excluded, no statistically significant difference in sensitivity, specificity, positive predictive value, negative predictive value, or overall accuracy were found when comparing the different imaging techniques. In the per-patient analysis, equivocal scans were either assumed positive for metastases ("pessimistic analysis") or assumed negative for metastases ("optimistic analysis"). The percentages of misdiagnosed patients for the pessimistic analysis were 21%, 15%, 9%, and 7% for pBS, SPECT/CT, PET/CT, and PET/MRI, respectively. Corresponding figures for the optimistic analysis were 9%, 12%, 5%, and 7%. In those patients identified as having bone metastases according to the reference standard, SPECT/CT, 18 F-NaF PET/CT, and PET/MRI detected additional lesions compared with pBS in 31%, 63%, and 71%, respectively. Conclusion: 18 F-NaF PET/CT and whole-body SPECT/CT resulted in a significant reduction of equivocal readings compared with pBS, which implies an improved diagnostic confidence. However, the clinical benefit of using, for example, 18 F-NaF PET/CT or PET/MRI as compared with SPECT/CT and pBS in this patient population with a relatively low prevalence of bone metastases (14%) is likely limited. This conclusion is influenced by the low prevalence of patients with osseous metastases. There may well be significant differences in the sensitivity of SPECT/CT, PET/CT, and PET/MRI compared with pBS, but a larger patient population or a patient population with a higher prevalence of bone metastases would have to be studied to demonstrate this. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  18. Fibrosis in nonalcoholic fatty liver disease: Noninvasive assessment using computed tomography volumetry.

    PubMed

    Fujita, Nobuhiro; Nishie, Akihiro; Asayama, Yoshiki; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Shirabe, Ken; Yoshizumi, Tomoharu; Kotoh, Kazuhiro; Furusyo, Norihiro; Hida, Tomoyuki; Oda, Yoshinao; Fujioka, Taisuke; Honda, Hiroshi

    2016-10-28

    To evaluate the diagnostic performance of computed tomography (CT) volumetry for discriminating the fibrosis stage in patients with nonalcoholic fatty liver disease (NAFLD). A total of 38 NAFLD patients were enrolled. On the basis of CT imaging, the volumes of total, left lateral segment (LLS), left medial segment, caudate lobe, and right lobe (RL) of the liver were calculated with a dedicated liver application. The relationship between the volume percentage of each area and fibrosis stage was analyzed using Spearman's rank correlation coefficient. A receiver operating characteristic (ROC) curve analysis was performed to determine the accuracy of CT volumetry for discriminating fibrosis stage. The volume percentages of the caudate lobe and the LLS significantly increased with the fibrosis stage ( r = 0.815, P < 0.001; and r = 0.465, P = 0.003, respectively). Contrarily, the volume percentage of the RL significantly decreased with fibrosis stage ( r = -0.563, P < 0.001). The volume percentage of the caudate lobe had the best diagnostic accuracy for staging fibrosis, and the area under the ROC curve values for discriminating fibrosis stage were as follows: ≥ F1, 0.896; ≥ F2, 0.929; ≥ F3, 0.955; and ≥ F4, 0.923. The best cut-off for advanced fibrosis (F3-F4) was 4.789%, 85.7% sensitivity and 94.1% specificity. The volume percentage of the caudate lobe calculated by CT volumetry is a useful diagnostic parameter for staging fibrosis in NAFLD patients.

  19. Body-wide anatomy recognition in PET/CT images

    NASA Astrophysics Data System (ADS)

    Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Zhao, Liming; Torigian, Drew A.

    2015-03-01

    With the rapid growth of positron emission tomography/computed tomography (PET/CT)-based medical applications, body-wide anatomy recognition on whole-body PET/CT images becomes crucial for quantifying body-wide disease burden. This, however, is a challenging problem and seldom studied due to unclear anatomy reference frame and low spatial resolution of PET images as well as low contrast and spatial resolution of the associated low-dose CT images. We previously developed an automatic anatomy recognition (AAR) system [15] whose applicability was demonstrated on diagnostic computed tomography (CT) and magnetic resonance (MR) images in different body regions on 35 objects. The aim of the present work is to investigate strategies for adapting the previous AAR system to low-dose CT and PET images toward automated body-wide disease quantification. Our adaptation of the previous AAR methodology to PET/CT images in this paper focuses on 16 objects in three body regions - thorax, abdomen, and pelvis - and consists of the following steps: collecting whole-body PET/CT images from existing patient image databases, delineating all objects in these images, modifying the previous hierarchical models built from diagnostic CT images to account for differences in appearance in low-dose CT and PET images, automatically locating objects in these images following object hierarchy, and evaluating performance. Our preliminary evaluations indicate that the performance of the AAR approach on low-dose CT images achieves object localization accuracy within about 2 voxels, which is comparable to the accuracies achieved on diagnostic contrast-enhanced CT images. Object recognition on low-dose CT images from PET/CT examinations without requiring diagnostic contrast-enhanced CT seems feasible.

  20. Value of 18F-FDG PET/CT Combined With Tumor Markers in the Evaluation of Ascites.

    PubMed

    Han, Na; Sun, Xun; Qin, Chunxia; Hassan Bakari, Khamis; Wu, Zhijian; Zhang, Yongxue; Lan, Xiaoli

    2018-05-01

    The purpose of this study is to investigate the value of 18 F-FDG PET/CT combined with assessment of tumor markers in serum or ascites for the diagnosing and determining the prognosis of benign and malignant ascites. Patients with ascites of unknown cause who underwent evaluation with FDG PET/CT were included in this retrospective study. The maximum standardized uptake value (SUV max ) and levels of the tumor markers carbohydrate antigen-125 (CA-125) and carcinoembryonic antigen (CEA) in serum and ascites were recorded. The diagnostic values of FDG PET/CT, CEA and CA-125 levels in serum or ascites, and the combination of imaging plus tumor marker assessment were evaluated. Factors that were predictive of survival were also analyzed. A total of 177 patients were included. Malignant ascites was eventually diagnosed in 104 patients, and benign ascites was diagnosed in the remaining 73 patients. With the use of FDG PET/CT, 44 patients (42.3%) were found to have primary tumors. The sensitivity, specificity, and accuracy of FDG PET/CT were 92.3%, 83.6%, and 88.7%, respectively. CA-125 levels in serum and ascites showed much better sensitivity than did CEA levels, but they showed significantly lower specificity. If the combination of tumor markers and FDG PET/CT was analyzed, the sensitivity, specificity, and accuracy of tumor markers in serum were 96.6%, 78.1%, and 88.7%, and those of tumor markers in ascites were 97.7%, 80.0%, and 90.4%, respectively. Sex may be an important factor affecting survival time (hazard ratio, 0.471; p = 0.004), but age, CEA level, and FDG PET/CT findings could not predict survival. FDG PET/CT combined with assessment of tumor markers, especially CEA, increased the efficacy of diagnosis of ascites of unknown causes. Male sex conferred a poorer prognosis, whereas age, CEA level, and FDG uptake had no predictive significance in patients with malignant ascites.

  1. Incremental value of the CT coronary calcium score for the prediction of coronary artery disease

    PubMed Central

    Genders, Tessa S. S.; Pugliese, Francesca; Mollet, Nico R.; Meijboom, W. Bob; Weustink, Annick C.; van Mieghem, Carlos A. G.; de Feyter, Pim J.

    2010-01-01

    Objectives: To validate published prediction models for the presence of obstructive coronary artery disease (CAD) in patients with new onset stable typical or atypical angina pectoris and to assess the incremental value of the CT coronary calcium score (CTCS). Methods: We searched the literature for clinical prediction rules for the diagnosis of obstructive CAD, defined as ≥50% stenosis in at least one vessel on conventional coronary angiography. Significant variables were re-analysed in our dataset of 254 patients with logistic regression. CTCS was subsequently included in the models. The area under the receiver operating characteristic curve (AUC) was calculated to assess diagnostic performance. Results: Re-analysing the variables used by Diamond & Forrester yielded an AUC of 0.798, which increased to 0.890 by adding CTCS. For Pryor, Morise 1994, Morise 1997 and Shaw the AUC increased from 0.838 to 0.901, 0.831 to 0.899, 0.840 to 0.898 and 0.833 to 0.899. CTCS significantly improved model performance in each model. Conclusions: Validation demonstrated good diagnostic performance across all models. CTCS improves the prediction of the presence of obstructive CAD, independent of clinical predictors, and should be considered in its diagnostic work-up. PMID:20559838

  2. Utility of PET/CT to Evaluate Retroperitoneal Lymph Node Metastasis in High-Risk Endometrial Cancer: Results of ACRIN 6671/GOG 0233 Trial.

    PubMed

    Atri, Mostafa; Zhang, Zheng; Dehdashti, Farrokh; Lee, Susanna I; Marques, Helga; Ali, Shamshad; Koh, Wui-Jin; Mannel, Robert S; DiSilvestro, Paul; King, Stephanie A; Pearl, Michael; Zhou, XunClare; Plante, Marie; Moxley, Katherine M; Gold, Michael

    2017-05-01

    Purpose To assess the diagnostic accuracy of fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) combined with diagnostic contrast material-enhanced computed tomography (CT) in detecting lymph node (LN) metastasis in high-risk endometrial cancer. Materials and Methods This prospective multicenter HIPAA-compliant study had institutional review board approval, and all participants gave written informed consent. Data were accrued between January 2010 and June 2013. Patients underwent PET/CT and pelvic and abdominal lymphadenectomy. Two hundred seven of 215 enrolled patients had PET/CT and pathologic examination results for the abdomen and pelvis. Mean patient age was 62.7 years ± 9.6 (standard deviation). Data in all 23 patients with a positive abdominal examination and in 26 randomly selected patients with a negative abdominal examination were used for this central reader study. Seven independent blinded readers reviewed diagnostic CT and PET/CT results in different sessions 1 month apart. Accuracy was calculated at the participant level, correlating abdominal (right and left para-aortic and common iliac) and pelvic (right and left external iliac and obturator) LN regions with pathologic results, respecting laterality. Reader-average sensitivities, specificities, and areas under the receiver operating characteristic curve (AUCs) of PET/CT and diagnostic CT were compared. Power calculation was for sensitivity and specificity in the abdomen. Results Sensitivities of PET/CT versus diagnostic CT for the detection of LN metastasis were 0.65 (95% confidence interval [CI]: 0.57, 0.72) versus 0.50 (95% CI: 0.43, 0.58) (P = .01) in the abdomen and 0.65 (95% CI: 0.57, 0.72) versus 0.48 (95% CI: 0.41, 0.56) (P = .004) in the pelvis. Corresponding specificities were 0.88 (95% CI: 0.83, 0.92) versus 0.93 (95% CI: 0.89, 0.96) (P = .11) and 0.93 (95% CI: 0.86, 0.96) versus 0.89 (95% CI: 0.82, 0.94) (P = .27), and AUCs were 0.78 (95% CI: 0.66, 0.89) versus 0.74 (95% CI: 0.63, 0.86) (P = .39) and 0.82 (95% CI: 0.71, 0.92) versus 0.73 (95% CI: 0.63, 0.84) (P = .02). Conclusion FDG PET/CT has satisfactory diagnostic accuracy in the detection of abdominal LN metastasis in high-risk endometrial cancer. Compared with diagnostic CT alone, addition of PET to diagnostic CT significantly increased sensitivity in both the abdomen and pelvis while maintaining high specificity. © RSNA, 2017 Online supplemental material is available for this article.

  3. Utility of PET/CT to Evaluate Retroperitoneal Lymph Node Metastasis in High-Risk Endometrial Cancer: Results of ACRIN 6671/GOG 0233 Trial

    PubMed Central

    Zhang, Zheng; Dehdashti, Farrokh; Lee, Susanna I.; Marques, Helga; Ali, Shamshad; Koh, Wui-Jin; Mannel, Robert S.; DiSilvestro, Paul; King, Stephanie A.; Pearl, Michael; Zhou, XunClare; Plante, Marie; Moxley, Katherine M.; Gold, Michael

    2017-01-01

    Purpose To assess the diagnostic accuracy of fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) combined with diagnostic contrast material–enhanced computed tomography (CT) in detecting lymph node (LN) metastasis in high-risk endometrial cancer. Materials and Methods This prospective multicenter HIPAA-compliant study had institutional review board approval, and all participants gave written informed consent. Data were accrued between January 2010 and June 2013. Patients underwent PET/CT and pelvic and abdominal lymphadenectomy. Two hundred seven of 215 enrolled patients had PET/CT and pathologic examination results for the abdomen and pelvis. Mean patient age was 62.7 years ± 9.6 (standard deviation). Data in all 23 patients with a positive abdominal examination and in 26 randomly selected patients with a negative abdominal examination were used for this central reader study. Seven independent blinded readers reviewed diagnostic CT and PET/CT results in different sessions 1 month apart. Accuracy was calculated at the participant level, correlating abdominal (right and left para-aortic and common iliac) and pelvic (right and left external iliac and obturator) LN regions with pathologic results, respecting laterality. Reader-average sensitivities, specificities, and areas under the receiver operating characteristic curve (AUCs) of PET/CT and diagnostic CT were compared. Power calculation was for sensitivity and specificity in the abdomen. Results Sensitivities of PET/CT versus diagnostic CT for the detection of LN metastasis were 0.65 (95% confidence interval [CI]: 0.57, 0.72) versus 0.50 (95% CI: 0.43, 0.58) (P = .01) in the abdomen and 0.65 (95% CI: 0.57, 0.72) versus 0.48 (95% CI: 0.41, 0.56) (P = .004) in the pelvis. Corresponding specificities were 0.88 (95% CI: 0.83, 0.92) versus 0.93 (95% CI: 0.89, 0.96) (P = .11) and 0.93 (95% CI: 0.86, 0.96) versus 0.89 (95% CI: 0.82, 0.94) (P = .27), and AUCs were 0.78 (95% CI: 0.66, 0.89) versus 0.74 (95% CI: 0.63, 0.86) (P = .39) and 0.82 (95% CI: 0.71, 0.92) versus 0.73 (95% CI: 0.63, 0.84) (P = .02). Conclusion FDG PET/CT has satisfactory diagnostic accuracy in the detection of abdominal LN metastasis in high-risk endometrial cancer. Compared with diagnostic CT alone, addition of PET to diagnostic CT significantly increased sensitivity in both the abdomen and pelvis while maintaining high specificity. © RSNA, 2017 Online supplemental material is available for this article. PMID:28051912

  4. Preliminary study on the diagnostic value of single-source dual-energy CT in diagnosing cervical lymph node metastasis of thyroid carcinoma

    PubMed Central

    Zhao, Yanfeng; Li, Xiaolu; Wang, Xiaoyi; Lin, Meng; Zhao, Xinming; Luo, Dehong; Li, Jianying

    2017-01-01

    Background To investigate the value of single-source dual-energy spectral CT imaging in improving the accuracy of preoperative diagnosis of lymph node metastasis of thyroid carcinoma. Methods Thirty-four thyroid carcinoma patients were enrolled and received spectral CT scanning before thyroidectomy and cervical lymph node dissection surgery. Iodine-based material decomposition (MD) images and 101 sets of monochromatic images from 40 to 140 keV were reconstructed after CT scans. The iodine concentrations (IC) of lymph nodes were measured on the MD images and was normalized to that of common carotid artery to obtain the normalized iodine concentration (NIC). The CT number of lymph nodes as function of photon energy was measured on the 101 sets of images to generate a spectral HU curve and to calculate its slope λHU. The measurements between the metastatic and non-metastatic lymph nodes were statistically compared and receiver operating characteristic (ROC) curves were used to determine the optimal thresholds of these measurements for diagnosing lymph nodes metastasis. Results There were 136 lymph nodes that were pathologically confirmed. Among them, 102 (75%) were metastatic and 34 (25%) were non-metastatic. The IC, NIC and the slope λHU of the metastatic lymph nodes were 3.93±1.58 mg/mL, 0.70±0.55 and 4.63±1.91, respectively. These values were statistically higher than the respective values of 1.77±0.71 mg/mL, 0.29±0.16 and 2.19±0.91 for the non-metastatic lymph nodes (all P<0.001). ROC analysis determined the optimal diagnostic threshold for IC as 2.56 mg/mL, with the sensitivity, specificity and accuracy of 83.3%, 91.2% and 85.3%, respectively. The optimal threshold for NIC was 0.289, with the sensitivity, specificity and accuracy of 96.1%, 76.5% and 91.2%, respectively. The optimal threshold for the spectral curve slope λHU was 2.692, with the sensitivity, specificity and accuracy of 88.2%, 82.4% and 86.8%, respectively. Conclusions The measurements obtained in dual-energy spectral CT improve the sensitivity and accuracy for preoperatively diagnosing lymph node metastasis in thyroid carcinoma. PMID:29268547

  5. Reader Training for the Restaging of Biochemically Recurrent Prostate Cancer Using 18F-Fluciclovine PET/CT.

    PubMed

    Miller, Matthew P; Kostakoglu, Lale; Pryma, Daniel; Yu, Jian Qin; Chau, Albert; Perlman, Eric; Clarke, Bonnie; Rosen, Donald; Ward, Penelope

    2017-10-01

    18 F-Fluciclovine is a novel PET/CT tracer. This blinded image evaluation (BIE) sought to demonstrate that, after limited training, readers naïve to 18 F-fluciclovine could interpret 18 F-fluciclovine images from subjects with biochemically recurrent prostate cancer with acceptable diagnostic performance and reproducibility. The primary objectives were to establish individual readers' diagnostic performance and the overall interpretation (2/3 reader concordance) compared with standard-of-truth data (histopathology or clinical follow-up) and to evaluate interreader reproducibility. Secondary objectives included comparison to the expert reader and assessment of intrareader reproducibility. Methods: 18 F-Fluciclovine PET/CT images ( n = 121) and corresponding standard-of-truth data were collected from 110 subjects at Emory University using a single-time-point static acquisition starting 5 min after injection of approximately 370 MBq of 18 F-fluciclovine. Three readers were trained using standardized interpretation methodology and subsequently evaluated the images in a blinded manner. Analyses were conducted at the lesion, region (prostate, including bed and seminal vesicle, or extraprostatic, including all lymph nodes, bone, or soft-tissue metastasis), and subject level. Results: Lesion-level overall positive predictive value was 70.5%. The readers' positive predictive value and negative predictive value were broadly consistent with each other and with the onsite read. Sensitivity was highest for readers 1 and 2 (68.5% and 63.9%, respectively) whereas specificity was highest for reader 3 (83.6%). Overall, prostate-level sensitivity was high (91.4%), but specificity was moderate (48.7%). Interreader agreement was 94.7%, 74.4%, and 70.3% for the lesion, prostate, and extraprostatic levels, respectively, with associated Fleiss' κ-values of 0.54, 0.50, and 0.57. Intrareader agreement was 97.8%, 96.9%, and 99.1% at the lesion level; 100%, 100%, and 91.7% in the prostate region; and 83.3%, 75.0%, and 83.3% in the extraprostatic region for readers 1, 2, and 3, respectively. Concordance between the BIE and the onsite reader exceeded 75% for each reader at the lesion, region, and subject levels. Conclusion: Specific training in the use of standardized interpretation methodology for assessment of 18 F-fluciclovine PET/CT images enables naïve readers to achieve acceptable diagnostic performance and reproducibility when staging recurrent prostate cancer. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  6. Relativity Screens for Misvalued Medical Services: Impact on Noninvasive Diagnostic Radiology.

    PubMed

    Rosenkrantz, Andrew B; Silva, Ezequiel; Hawkins, C Matthew

    2017-11-01

    In 2006, the AMA/Specialty Society Relative Value Scale Update Committee (RUC) introduced ongoing relativity screens to identify potentially misvalued medical services for payment adjustments. We assess the impact of these screens upon the valuation of noninvasive diagnostic radiology services. Data regarding relativity screens and relative value unit (RVU) changes were obtained from the 2016 AMA Relativity Assessment Status Report. All global codes in the 2016 Medicare Physician Fee Schedule with associated work RVUs were classified as noninvasive diagnostic radiology services versus remaining services. The frequency of having ever undergone a screen was compared between the two groups. Screened radiology codes were further evaluated regarding the RVU impact of subsequent revaluation. Of noninvasive diagnostic radiology codes, 46.0% (201 of 437) were screened versus 22.2% (1,460 of 6,575) of remaining codes (P < .001). Most common screens for which radiology codes were identified as potentially misvalued were (1) high expenditures (27.5%) and (2) high utilization (25.6%). The modality and body region most likely to be identified in a screen were CT (82.1%) and breast (90.9%), respectively. Among screened radiology codes, work RVUs, practice expense RVUs, and nonfacility total RVUs decreased in 20.3%, 65.9%, and 75.3%, respectively. All screened CT, MRI, brain, and spine codes exhibited decreased total RVUs. Policymakers' ongoing search for potentially misvalued medical services has disproportionately impacted noninvasive diagnostic radiology services, risking the introduction of unintended or artificial shifts in physician practice. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage.

    PubMed

    Watanabe, Yoshiyuki; Tsukabe, Akio; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tanaka, Hisashi; Yoshiya, Kazuhisa; Shimazu, Takeshi; Tomiyama, Noriyuki

    2014-04-01

    Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement. Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas. Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively. DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage.

  8. Scanning and War: Utility of FAST and CT in the Assessment of Battlefield Abdominal Trauma.

    PubMed

    Smith, Iain M; Naumann, David N; Marsden, Max E R; Ballard, Mark; Bowley, Douglas M

    2015-08-01

    To determine utilization and accuracy of focused assessment with sonography for trauma (FAST) and computed tomography (CT) in a mature military trauma system to inform service provision for future conflicts. FAST and CT scans undertaken by attending radiologists contribute to surgical decision making for battlefield casualties at the Joint Force, Role 3 Medical Treatment Facility at Camp Bastion (R3), Afghanistan. Registry data for abdominally injured casualties treated at R3 from July to November 2012 were matched to radiological and surgical records to determine diagnostic accuracy for FAST and CT and their influence on casualty management. A total of 468 casualties met inclusion criteria, of whom 85.0% underwent FAST and 86.1% abdominal CT; 159 (34.0%) had abdominal injuries. For detection of intra-abdominal injury, FAST sensitivity (Sn) was 0.56, specificity (Sp) 0.98, positive predictive value (PPV) 0.87, negative predictive value (NPV) 0.90, and accuracy (Acc) 0.89. For CT, Sn was 0.99, Sp 0.99, PPV 0.96, NPV 1.00, and Acc 0.99. Forty-six solid organ injuries were identified in 38 patients by CT; 17 were managed nonoperatively. A further 61 patients avoided laparotomy after CT confirmed extra-abdominal wounds only. The negative laparotomy rate was 3.9%. FAST and CT contribute to triage, guide surgical management, and reduce nontherapeutic laparotomy. When imaging is available, these data challenge current doctrine about inadvisability of nonoperative management of abdominal injury after combat trauma.

  9. [The value of bedside lung ultrasound in emergency-plus protocol for the assessment of lung consolidation and atelectasis in critical patients].

    PubMed

    Wang, Xiao-ting; Liu, Da-wei; Zhang, Hong-min; He, Huai-wu; Liu, Ye; Chai, Wen-zhao; Du, Wei

    2012-12-01

    To investigate the effect of the bedside lung ultrasound in emergency(BLUE)-plus lung ultrasound protocol on lung consolidation and atelectasis of critical patients. All patients who need to receive mechanical ventilation for more than 48 hours in ICU from June 2010 to December 2011 in Peking Union Medical College Hospital were included in the study. BLUE-plus and BLUE lung ultrasound, bedside X-ray, lung CT examination were performed on all patients at the same time. The condition of lung consolidation and atelectasis discovered by BLUE-plus lung ultrasound protocol was recorded and compared with bedside X-ray or lung CT. The difference in assessment of lung consolidation and atelectasis between BLUE-plus lung ultrasound protocol and BLUE protocol was compared. A total of 78 patients were finally enrolled in the study. The lung CT found 70 cases (89.74%) had different degrees of lung consolidation and atelectasis. The sensitivity, specificity and diagnostic accuracy of lung consolidation and atelectasis by the bedside chest X-ray were 31.29%, 75.00% and 38.46%, respectively. BLUE-plus lung ultrasound protocol found 68 cases with lung consolidation and atelectasis, and its sensitivity, specificity, and diagnostic accuracy were 95.71%, 87.50% and 94.87%, respectively, which were significantly higher than those of lung CT. BLUE protocol found 48 cases of lung consolidation and atelectasis, and its sensitivity, specificity, and diagnostic accuracy were 65.71%, 75.00% and 66.67%, respectively. The position of lung consolidation and atelectasis which hadn't been found by BLUE protocol was mainly proved to be located in the basement of lung by lung CT. The incidence of lung consolidation and atelectasis in critical patients who received mechanical ventilation is high. The BLUE-plus lung ultrasound protocol has a relatively higher sensitivity, specificity and diagnostic accuracy for consolidation and atelectasis, which can find majority of consolidation and atelectasis. As BLUE-plus lung ultrasound is a bedside noninvasive method allowing immediate assessment of most lung consolidation and atelectasis, it will be likely the alternative of the CT and play a key role in assessment of lung consolidation and atelectasis.

  10. Clinical Value of a One-Stop-Shop Low-Dose Lung Screening Combined with (18)F-FDG PET/CT for the Detection of Metastatic Lung Nodules from Colorectal Cancer.

    PubMed

    Han, Yeon-Hee; Lim, Seok Tae; Jeong, Hwan-Jeong; Sohn, Myung-Hee

    2016-06-01

    The aim of this study was to evaluate the clinical usefulness of additional low-dose high-resolution lung computed tomography (LD-HRCT) combined with (18)F-fluoro-2-deoxyglucose positron emission tomography with CT ((18)F-FDG PET/CT) compared with conventional lung setting image of (18)F-FDG PET/CT for the detection of metastatic lung nodules from colorectal cancer. From January 2011 to September 2011, 649 patients with colorectal cancer underwent additional LD-HRCT at maximum inspiration combined with (18)F-FDG PET/CT. Forty-five patients were finally diagnosed to have lung metastasis based on histopathologic study or clinical follow-up. Twenty-five of the 45 patients had ≤5 metastatic lung nodules and the other 20 patients had >5 metastatic nodules. One hundred and twenty nodules in the 25 patients with ≤5 nodules were evaluated by conventional lung setting image of (18)F-FDG PET/CT and by additional LD-HRCT respectively. Sensitivities, specificities, diagnostic accuracies, positive predictive values (PPVs), and negative predictive values (NPVs) of conventional lung setting image of (18)F-FDG PET/CT and additional LD-HRCT were calculated using standard formulae. The McNemar test and receiver-operating characteristic (ROC) analysis were performed. Of the 120 nodules in the 25 patients with ≤5 metastatic lung nodules, 66 nodules were diagnosed as metastatic. Eleven of the 66 nodules were confirmed histopathologically and the others were diagnosed by clinical follow-up. Conventional lung setting image of (18)F-FDG PET/CT detected 40 of the 66 nodules and additional LD-HRCT detected 55 nodules. All 15 nodules missed by conventional lung setting imaging but detected by additional LD-HRCT were <1 cm in size. The sensitivity, specificity, and diagnostic accuracy of the modalities were 60.6 %, 85.2 %, and 71.1 % for conventional lung setting image and 83.3 %, 88.9 %, and 85.8 % for additional LD-HRCT. By ROC analysis, the area under the ROC curve (AUC) of conventional lung setting image and additional LD-HRCT were 0.712 and 0.827 respectively. Additional LD-HRCT with maximum inspiration was superior to conventional lung setting image of (18)F-FDG PET/CT for the detection of metastatic lung nodules from colorectal cancer (P < 0.05).

  11. Para-aortic lymphadenectomy in advanced stage cervical cancer, a protocol for comparing safety, feasibility and diagnostic accuracy of surgical staging versus PET-CT; PALDISC trial.

    PubMed

    Tax, Casper; Abbink, Karin; Rovers, Maroeska M; Bekkers, Ruud L M; Zusterzeel, Petra L M

    2018-01-01

    Currently, a PET-CT is used to assess the need for extended field radiotherapy of para-aortic lymph nodes (PALN) in International Federation of Gynaecology and Obstetrics (FIGO) stage IB2, IIA2-IVA (locally advanced stage) cervical cancer. A small study established a sensitivity and specificity estimate for PALN metastases of 50% (95% CI; 7-93%) and 83% (95% CI; 52-98%), respectively. Surgical staging of PALN may lead to a higher diagnostic accuracy. However, surgical staging of para-aortic lymph nodes in locally advanced stage cervical cancer is not common practice. Therefore, a phase 2 randomised controlled trial is needed to assess its safety and feasibility. In addition to standard imaging (MRI or CT scan) with PET-CT, 30 adult women with FIGO stage IB2, IIA2-IVA cervical cancer will be randomised to receive either surgical staging or usual PET-CT staging. Administering extended field radiotherapy will be based on lymphadenectomy results for the intervention group and on the PET-CT results for the control group. Follow-up visits at 0, 3, 6, 9 and 12 months will assess health-related quality of life and progression-free survival.Primary safety and feasibility outcomes of surgical staging will be assessed by calculating means with 95% confidence intervals for duration of surgery, number of complications, blood loss, nodal yield after para-aortic lymphadenectomy and treatment delay due to surgical staging. Secondary patient-centred outcomes on quality of life and first year survival will be documented and compared between the two groups. Estimates of sensitivity, specificity and negative and positive predictive values of MRI, PET-CT and surgical staging will be presented with 95% CI.. All analysis will be performed according to the intention to treat principle. This study will assess safety and feasibility, expressed as the number and severity of complications, effect on quality of life and the treatment delay due to surgically staging para-aortic lymph nodes in locally advanced cervical cancer. It will provide insight in the diagnostic accuracy of the PET-CT and detection rate of missed (micro)metastases due to surgical staging. This information will be used to assess the necessity for a phase 3 study on the diagnostic accuracy of the PET-CT and surgical staging. If a phase 3 study is deemed necessary, current data can be used for sample size calculation of such a phase 3 study. Nederlands Trial Register/Dutch Trial Registry (www.trialregister.nl), NTR4922. Registered on 24 November 2014.

  12. Value of CT added to ultrasonography for the diagnosis of lymph node metastasis in patients with thyroid cancer.

    PubMed

    Lee, Younghen; Kim, Ji-Hoon; Baek, Jung Hwan; Jung, So Lyung; Park, Sun-Won; Kim, Jinna; Yun, Tae Jin; Ha, Eun Ju; Lee, Kyu Eun; Kwon, Soon Young; Yang, Kyung-Sook; Na, Dong Gyu

    2018-05-13

    The benefit of CT for the diagnosis of lymph node metastasis in patients with thyroid cancer is still unclear. Three hundred fifty-one patients with thyroid cancers from 7 hospitals were prospectively enrolled in order to compare diagnostic performance between a combination of ultrasound and CT (ultrasound/CT) and ultrasound alone for prediction of lymph node metastasis and to calculate patient-based benefits of CT added to ultrasound. Of 801 pathologically proven neck levels, ultrasound/CT showed higher sensitivities in both central and lateral compartments and improved accuracy in the lateral compartment compared to ultrasound alone. In the retropharyngeal/superior mediastinal compartment, although CT could detect lymph node metastasis an ultrasound could not. Patient-based benefit was demonstrated in 13.1% of patients (46/351), and was higher in patients with cancers >1 cm than cancers ≤1 cm. In patients with thyroid cancer, CT improved surgical planning by enhancing the sensitivity for lymph node metastasis and by detecting lymph node metastasis that was overlooked with ultrasound alone. © 2018 Wiley Periodicals, Inc.

  13. Adaptive prospective ECG-triggered sequence coronary angiography in dual-source CT without heart rate control: Image quality and diagnostic performance.

    PubMed

    Pan, Chang-Jie; Qian, Nong; Wang, Tao; Tang, Xiao-Qiang; Xue, Yue-Jun

    2013-02-01

    The aim of this study was to evaluate the accuracy of using second generation dual-source CT (DSCT) to obtain high quality images and diagnostic performance and to reduce the radiation dose in adaptive prospective electrocardiography (ECG)-triggered sequence (CorAdSeq) CT coronary angiography (CTCA) without heart rate control. No prescan β-blockers were administered. Un-enhanced CT and CTCA with adaptive prospective CorAdSeq scanning without heart rate control were performed in 683 consecutive patients divided into two body mass index (BMI) groups: BMI <25 kg/m(2) (group A, n=412) and BMI ≥25 kg/m(2) (group B, n=271). The image quality and quantitative stenosis of all coronary segments with a diameter ≥1 mm were assessed. The mean heart rate (MHR), heart rate variability (HRV) and radiation dose values were recorded. In 426 cases, the diagnostic performance was evaluated using quantitative conventional coronary angiography as the reference standard. Diagnostic image quality was obtained in 98.5% of segments in group A and in 98.8% of segments in group B, with no significant differences between the groups. No correlations were observed between the image quality score and MHR or HRV (P=0.492, P=0.564, respectively). The effective radiation doses in groups A and B were 2.57±1.01 mSv and 6.36±1.88 mSv, respectively. The sensitivities and specificities of diagnosing coronary heart disease per patient were 99.6% and 97.8% in group A and 99.5% and 97.5% in group B, respectively (P>0.05). Adaptive prospective CorAdSeq scanning, without heart rate control, by second generation DSCT had a high image quality and diagnostic performance for coronary artery stenosis with lower radiation doses.

  14. Liver Contrast-Enhanced Ultrasound Improves Detection of Liver Metastases in Patients with Pancreatic or Periampullary Cancer.

    PubMed

    Taimr, Pavel; Jongerius, Vivian L; Pek, Chulja J; Krak, Nanda C; Hansen, Bettina E; Janssen, Harry L A; Metselaar, Herold J; van Eijck, Casper H J

    2015-12-01

    The aim of this study is to provide a diagnostic performance evaluation of contrast-enhanced ultrasonography (CEUS) in detecting liver metastases in patients with suspected of pancreatic or periampullary cancer. Computed tomography (CT) is often insufficient for detection of liver metastases, but their presence plays a crucial role in the choice of therapy. Eighty-nine patients with suspected pancreatic or periampullary cancer were included in this prospective study with retrospective analysis. Patients underwent an abdominal CT and CEUS. Fifteen patients had liver metastases. The CT sensitivity was 73.3% (11/15), the specificity 93.2% (69/74), the positive predictive value (PPV) 68.8% (11/16) and the negative predictive value (NPV) 94.6% (69/73). Based on CEUS, the sensitivity was 80% (12/15), specificity 98.6% (73/74), PPV 92.3% (12/13) and NPV 96.1% (73/76). CEUS improved characterization of liver lesions in patients with suspected pancreatic or periampullary cancer compared with CT. CEUS can better detect benign liver lesions and distinguish false-positive or indeterminate CT results. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Primary hypolactasia diagnosis: Comparison between the gaxilose test, shortened lactose tolerance test, and clinical parameters corresponding to the C/T-13910 polymorphism.

    PubMed

    Domínguez Jiménez, José Luis; Fernández Suárez, Antonio; Muñoz Colmenero, Aurora Úrsula; Fatela Cantillo, Daniel; López Pelayo, Iratxe

    2017-04-01

    There is no consensus on the most accurate method to diagnose primary hypolactasia. We aimed to compare the diagnostic accuracy of the new gaxilose test with 2 traditional tests (lactose tolerance test and clinical criteria) for the diagnosis of primary hypolactasia using the C/T-13910 polymorphism as a reference standard. Patients with a clinical suspicion of lactose intolerance were subjected to gaxilose tests, shortened lactose tolerance tests, and symptom questionnaires before and after overload with 50 g lactose and after a lactose-free diet. The diagnostic accuracy and degree of agreement and correlation were assessed using a genetic test (C/T-13910 polymorphism) as a reference standard and their respective 95% confidence intervals. Thirty consecutive patients (70% women) participated in the study. The genetic test confirmed the C/T-13910 polymorphism in 11 patients (36.8%). The presence of diarrhoea and the symptom score after lactose overload, along with the tolerance test, were the variables with the highest degree of agreement (κ > 0.60). Area under the ROC curve was >0.82 (p < 0.05), with sensitivity and specificity values of >0.80. However, the gaxilose test obtained lower values: κ, 0.47; area under curve, 0.75 (0.57-0.94); sensitivity, 0.82 (0.55-1); and specificity, 0.68 (0.45-0.92). The multivariate analysis showed an association between the post-overload symptom questionnaire and the results of the genetic test (odds ratio: 1.17; 1.04-1.31; p < 0.01). The presence of diarrhoea and the symptom score after overload with 50 g lactose showed a higher degree of agreement and diagnostic accuracy for primary hypolactasia than the gaxilose test when the genetic test is used as a reference standard. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  16. Use of Magnetic Resonance Imaging for N-Staging in Patients with Non-Small Cell Lung Cancer. A Systematic Review.

    PubMed

    Brea, Tara Pereiro; Raviña, Alberto Ruano; Villamor, José Martín Carreira; Gómez, Antonio Golpe; de Alegría, Anxo Martínez; Valdés, Luís

    2018-05-23

    The aim of this study is to assess the diagnostic value of the magnetic resonance imaging (MRI) in differentiating metastasic from non-metastatic lymph nodes in NSCLC patients compared with computed tomography (CT) and fluorodeoxyglucose (FDG) - positron emission tomography (PET) or both combined. Twenty-three studies (19 studies and 4 meta-analysis) with sample size ranging between 22 and 250 patients were included in this analysis. MRI, regardless of the sequence obtained, where used for the evaluation of N-staging of NSCLC. Histopathology results and clinical or imaging follow-up were used as the reference standard. Studies were excluded if the sample size was less than 20 cases, if less than 10 lymph nodes assessment were presented or studies where standard reference was not used. Papers not reporting sufficient data were also excluded. As compared to CT and PET, MRI demonstrated a higher sensitivity, specificity and diagnostic accuracy in the diagnosis of metastatic or non-metastatic lymph nodes in N-staging in NSCLC patients. No study considered MRI inferior than conventional techniques (CT, PET or PET/CT). Other outstanding results of this review are fewer false positives with MRI in comparison with PET, their superiority over PET/CT to detect non-resectable lung cancer, to diagnosing infiltration of adjacent structures or brain metastasis and detecting small nodules. MRI has shown at least similar or better results in diagnostic accuracy to differentiate metastatic from non-metastatic mediastinal lymph nodes. This suggests that MRI could play a significant role in mediastinal NSCLC staging. Copyright © 2018 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. GIANT CELL AORTITIS DIAGNOSED WITH PET/CT - PARANEOPLASTIC SYNDROME?

    PubMed

    Bakula, Marija; Cerovec, Mislav; Mayer, Miroslav; Huić, Dražen; Anić, Branimir

    2016-05-01

    Vasculitides are heterogenic group of autoimmune connective tissue diseases which often present difficulties in early diagnosing. Giant cell arteritis is vasculitis of large and medium arteries. It predominantly presents with symptoms of affection of the external carotid artery branches. Furthermore, the only symptoms can be constitutional. In clinical practice, vasculitides are sometimes considered as paraneoplastic, but no definite association with malignancies has been established and the mechanisms are still debated. The gold standard for diagnosing giant cell arteritis is a positive temporal artery biopsy, but the results can often be false negative. Additionally, more than half of the patients have aorta and its main branches affected. Considering aforementioned, imaging studies are essential in confirming large-vessel vasculitis, amongst which is highly sensitive PET/CT. We present the case of a 70-year-old female patient with constitutional symptoms and elevated sedimentation rate. After extensive diagnostic tests, she was admitted to our Rheumatology unit. Aortitis of the abdominal aorta has been confirmed by PET/CT and after the introduction of glucocorticoids the disease soon went into clinical and laboratory remission. Shortly after aortitis has been diagnosed, lung carcinoma was revealed of which the patient died. At the time of the comprehensive diagnostics, there was no reasonable doubt for underlying malignoma. To the best of our knowledge, there are no recent publications concerning giant cell arteritis and neoplastic processes in the context of up-to-date non-invasive diagnostic methods (i.e. PET/CT). In the light of previous research results, we underline that the sensitivity of PET/CT is not satisfactory when estimating cancer dissemination in non-enlarged lymph nodes and that its value can at times be overestimated.

  18. Dental flat panel conebeam CT in the evaluation of patients with inflammatory sinonasal disease: Diagnostic efficacy and radiation dose savings.

    PubMed

    Leiva-Salinas, C; Flors, L; Gras, P; Más-Estellés, F; Lemercier, P; Patrie, J T; Wintermark, M; Martí-Bonmatí, L

    2014-01-01

    CT is the imaging modality of choice to study the paranasal sinuses; unfortunately, it involves significant radiation dose. Our aim was to assess the diagnostic validity, image quality, and radiation-dose savings of dental conebeam CT in the evaluation of patients with suspected inflammatory disorders of the paranasal sinuses. We prospectively studied 40 patients with suspected inflammatory disorders of the sinuses with dental conebeam CT and standard CT. Two radiologists analyzed the images independently, blinded to clinical information. The image quality of both techniques and the diagnostic validity of dental conebeam CT compared with the reference standard CT were assessed by using 3 different scoring systems. Image noise, signal-to-noise ratio, and contrast-to-noise ratio were calculated for both techniques. The absorbed radiation dose to the lenses and thyroid and parotid glands was measured by using a phantom and dosimeter chips. The effective radiation dose for CT was calculated. All dental conebeam CT scans were judged of diagnostic quality. Compared with CT, the conebeam CT image noise was 37.3% higher (P < .001) and the SNR of the bone was 75% lower (P < .001). The effective dose of our conebeam CT protocol was 23 μSv. Compared with CT, the absorbed radiation dose to the lenses and parotid and thyroid glands with conebeam CT was 4%, 7.8%, and 7.3% of the dose delivered to the same organs by conventional CT (P < .001). Dental conebeam CT is a valid imaging procedure for the evaluation of patients with inflammatory sinonasal disorders. © 2014 by American Journal of Neuroradiology.

  19. Utility of Dual-Energy CT-based Monochromatic Imaging in the Assessment of Myocardial Delayed Enhancement in Patients with Cardiomyopathy.

    PubMed

    Chang, Suyon; Han, Kyunghwa; Youn, Jong-Chan; Im, Dong Jin; Kim, Jin Young; Suh, Young Joo; Hong, Yoo Jin; Hur, Jin; Kim, Young Jin; Choi, Byoung Wook; Lee, Hye-Jeong

    2018-05-01

    Purpose To investigate the diagnostic utility of dual-energy computed tomography (CT)-based monochromatic imaging for myocardial delayed enhancement (MDE) assessment in patients with cardiomyopathy. Materials and Methods The institutional review board approved this prospective study, and informed consent was obtained from all participants who were enrolled in the study. Forty patients (27 men and 13 women; mean age, 56 years ± 15 [standard deviation]; age range, 22-81 years) with cardiomyopathy underwent cardiac magnetic resonance (MR) imaging and dual-energy CT. Conventional (120-kV) and monochromatic (60-, 70-, and 80-keV) images were reconstructed from the dual-energy CT acquisition. Subjective quality score, contrast-to-noise ratio (CNR), and beam-hardening artifacts were compared pairwise with the Friedman test at post hoc analysis. With cardiac MR imaging as the reference standard, diagnostic performance of dual-energy CT in MDE detection and its predictive ability for pattern classification were compared pairwise by using logistic regression analysis with the generalized estimating equation in a per-segment analysis. The Bland-Altman method was used to find agreement between cardiac MR imaging and CT in MDE quantification. Results Among the monochromatic images, 70-keV CT images resulted in higher subjective quality (mean score, 3.38 ± 0.54 vs 3.15 ± 0.43; P = .0067), higher CNR (mean, 4.26 ± 1.38 vs 3.93 ± 1.33; P = .0047), and a lower value for beam-hardening artifacts (mean, 3.47 ± 1.56 vs 4.15 ± 1.67; P < .0001) when compared with conventional CT. When compared with conventional CT, 70-keV CT showed improved diagnostic performance for MDE detection (sensitivity, 94.6% vs 90.4% [P = .0032]; specificity, 96.0% vs 94.0% [P = .0031]; and accuracy, 95.6% vs 92.7% [P < .0001]) and improved predictive ability for pattern classification (subendocardial, 91.5% vs 84.3% [P = .0111]; epicardial, 94.3% vs 73.5% [P = .0001]; transmural, 93.0% vs 77.7% [P = .0018]; mesocardial, 85.4% vs 69.2% [P = .0047]; and patchy. 84.4% vs 78.4% [P = .1514]). For MDE quantification, 70-keV CT showed a small bias 0.1534% (95% limits of agreement: -4.7013, 5.0080). Conclusion Dual-energy CT-based 70-keV monochromatic images improve MDE assessment in patients with cardiomyopathy via improved image quality and CNR and reduced beam-hardening artifacts when compared with conventional CT images. © RSNA, 2017 Online supplemental material is available for this article.

  20. The usefulness of fluorine-18 fluorodeoxyglucose PET in the detection of recurrence in patients with differentiated thyroid cancer with elevated thyroglobulin and negative radioiodine whole-body scan.

    PubMed

    Stangierski, Adam; Kaznowski, Jaroslaw; Wolinski, Kosma; Jodlowska, Elzbieta; Michaliszyn, Piotr; Kubiak, Katarzyna; Czepczynski, Rafal; Ruchala, Marek

    2016-09-01

    PET/computed tomography (CT) using fluorine-18 fluorodeoxyglucose (F-FDG) has been used in the diagnosis of recurrence and metastases of differentiated thyroid cancer (DTC) in cases of negative whole-body scan (WBS) despite elevated concentrations of stimulated thyroglobulin (Tg). To assess the utility of PET/CT in the detection of recurrence among patients with DTC with increased Tg levels and negative results of WBS. PET/CT results were retrospectively analyzed in patients with DTC with increased Tg and negative results of WBS as well as negative cervical ultrasonography and chest radiography. PET-CT was performed 1-2 weeks after recent diagnostics under conditions of endogenous or exogenous thyroid-stimulating hormone stimulation. PET/CT was performed using a Discovery ST scanner 1 h after an intravenously F-FDG injection (activity 4-5 MBq/kg). To determine the cutoff value of Tg, receiver operating characteristic curves were analyzed. Sixty-nine patients with DTC (48 women, 21 men) aged 22-83 years (mean 50.9±17.5 years) were qualified. In 44 patients (63.8%), PET/CT indicated lesions of DTC. Thirty (43.5%) patients had F-FDG positive findings. In the remaining 14 patients (20.3%), lesions were found in CT only. Patients with a positive PET/CT scan had significantly higher Tg values than patients with a negative PET/CT (mean 143.8 vs. 26.5 ng/ml, P=0.03). The cutoff value of Tg concentration measured with the receiver operating characteristic analysis was 32.9 ng/ml. PET/CT is a useful tool in the detection of recurrence among thyroid cancer patients in cases of conflicting results of standard procedures, particularly for those with high Tg levels and negative WBS. The probability of obtaining a positive PET-CT result increases with the level of Tg.

  1. The significance of 99mTc-MAA SPECT/CT liver perfusion imaging in treatment planning for 90Y-microsphere selective internal radiation treatment.

    PubMed

    Ahmadzadehfar, Hojjat; Sabet, Amir; Biermann, Kim; Muckle, Marianne; Brockmann, Holger; Kuhl, Christiane; Wilhelm, Kai; Biersack, Hans-Jürgen; Ezziddin, Samer

    2010-08-01

    Selective internal radiation therapy (SIRT), a catheter-based liver-directed modality for treating primary and metastatic liver cancer, requires appropriate planning to maximize its therapeutic response and minimize its side effects. (99m)Tc-macroaggregated albumin (MAA) scanning should precede the therapy to detect any extrahepatic shunting to the lung or gastrointestinal tract. Our aim was to compare the ability of SPECT/CT with that of planar imaging and SPECT in the detection and localization of extrahepatic (99m)Tc-MAA accumulation and to evaluate the impact of SPECT/CT on SIRT treatment planning and its added value to angiography in this setting. Ninety diagnostic hepatic angiograms with (99m)Tc-MAA were obtained for 76 patients with different types of cancer. All images were reviewed retrospectively for extrahepatic MAA deposition in the following order: planar, non-attenuation-corrected SPECT, and SPECT/CT. Review of angiograms and follow-up of patients with abdominal shunting served as reference standards. Extrahepatic accumulation was detected by planar imaging, SPECT, and SPECT/CT in 12%, 17%, and 42% of examinations, respectively. The sensitivity for detecting extrahepatic shunting with planar imaging, SPECT, and SPECT/CT was 32%, 41%, and 100%, respectively; specificity was 98%, 98%, and 93%, respectively. The respective positive predictive values were 92%, 93%, and 89%, and the respective negative predictive values were 71%, 73%, and 100%. The therapy plan was changed according to the results of planar imaging, SPECT, and SPECT/CT in 7.8%, 8.9%, and 29% of patients, respectively. In pre-SIRT planning, (99m)Tc-MAA SPECT/CT is valuable for identifying extrahepatic visceral sites at risk for postradioembolization complications.

  2. Rectosigmoid endometriosis: comparison between CT water enema and video laparoscopy.

    PubMed

    Stabile Ianora, A A; Moschetta, M; Lorusso, F; Lattarulo, S; Telegrafo, M; Rella, L; Scardapane, A

    2013-09-01

    To evaluate the accuracy of water enema computed tomography (CT) for predicting the location of endometriosis in patients with contraindications to magnetic resonance imaging (MRI), focusing on rectosigmoid lesions and having laparoscopic and histological data as the reference standard. Thirty-three women (mean age 33.4 ± 3.1 years) suspected of having deep pelvic endometriosis underwent 64-row CT and video laparoscopy within 4 weeks. Two radiologists blinded to the clinical data evaluated the CT images obtained after colonic retrograde distension using water as the contrast medium, and a comparison with laparoscopic and histological findings was performed. CT sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. The radiation dose to patients was estimated. Cohen's weighted kappa (κ) test was used to evaluate the interobserver agreement. In 23 out of 33 patients (69%) intestinal implants were found at surgery and pathological examinations. CT confirmed the diagnosis of rectosigmoid endometriosis in 20 out of 23 implants. Three nodules located on the proximal sigmoid colon (two serosal lesions and one infiltrating the muscularis layer) with a diameter of less than 1 cm were not diagnosed. CT sensitivity, specificity, PPV, NPV, and accuracy values were 87, 100, 100, 77, and 91%, respectively. The mean effective dose estimate was 6.30 ± 1.7 mSv. Almost perfect agreement between the two readers was found (k = 0.84). Water enema CT can play a role in the diagnosis of bowel endometriosis and represents another accurate potential tool for video laparoscopic approaches, especially in patients for whom MRI is contraindicated. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  3. Circulating tumor DNA evaluated by Next-Generation Sequencing is predictive of tumor response and prolonged clinical benefit with nivolumab in advanced non-small cell lung cancer.

    PubMed

    Giroux Leprieur, Etienne; Herbretau, Guillaume; Dumenil, Coraline; Julie, Catherine; Giraud, Violaine; Labrune, Sylvie; Dumoulin, Jennifer; Tisserand, Julie; Emile, Jean-François; Blons, Hélène; Chinet, Thierry

    2018-01-01

    Nivolumab is an anti-PD1 antibody, given in second-line or later treatment in advanced non-small cell lung cancer (NSCLC). The objective of this study was to describe the predictive value of circulating tumor DNA (ctDNA) on the efficacy of nivolumab in advanced NSCLC. We prospectively included all consecutive patients with advanced NSCLC treated with nivolumab in our Department between June 2015 and October 2016. Plasma samples were obtained before the first injection of nivolumab and at the first tumor evaluation with nivolumab. ctDNA was analyzed by Next-Generation Sequencing (NGS), and the predominant somatic mutation was followed for each patient and correlated with tumor response, clinical benefit (administration of nivolumab for more than 6 months), and progression-free survival (PFS). Of 23 patients, 15 had evaluable NGS results at both times of analysis. ctDNA concentration at the first tumor evaluation and ctDNA change correlated with tumor response, clinical benefit and PFS. ROC curve analyses showed good diagnostic performances for tumor response and clinical benefit, both for ctDNA concentration at the first tumor evaluation (tumor response: positive predictive value (PPV) at 100.0% and negative predictive value (NPV) at 71.0%; clinical benefit: PPV at 83.3% and NPV 77.8%) and the ctDNA change (tumor response: PPV 100.0% and NPV 62.5%; clinical benefit: PPV 100.0% and NPV 80.0%). Patients without ctDNA concentration increase >9% at 2 months had a long-term benefit of nivolumab. In conclusion, NGS analysis of ctDNA allows the early detection of tumor response and long-term clinical benefit with nivolumab in NSCLC.

  4. Sagittal-lung CT measurements in the evaluation of asthma-COPD overlap syndrome: a distinctive phenotype from COPD alone.

    PubMed

    Qu, Yanjuan; Cao, Yiyuan; Liao, Meiyan; Lu, Zhiyan

    2017-07-01

    This study aimed at investigating the capability of sagittal-lung computed tomography (CT) measurements in differentiating chronic obstructive pulmonary disease (COPD) and asthma-COPD overlap syndrome (ACOS). Clinical and high-resolution CT of 229 patients including 123 pure COPD patients and 106 ACOS patients were included. Sagittal-lung CT measurements in terms of bilateral lung height (LH), anterior-posterior lung diameter (APLD), diaphragm height (DH), and anterior sterno-diaphragmatic angle (ASDA), as well as inter-pulmonary septum length (IPSL) on axial images were measured both before and after bronchodilator (BD) administration. Comparisons of clinical characteristics and CT measurements between patient groups were performed. All pre-BD quantitative sagittal features measuring diaphragm flattening and hyperinflation were not significantly different between patients with COPD and patients with ACOS (P values all >0.05). Following BD administration, the ACOS patients exhibited lower left LH, bilateral APLD, and bilateral ASDA, but higher right DH, compared to pure COPD patients (P values all <0.05). Right LH, left DH and IPSL were not significantly different between patient groups. Besides, variations of all sagittal-lung CT measurements were significantly larger in patients with ACOS than in patients with pure COPD (P values all <0.001) and showed high performance in differentiating these two kinds of patient, with diagnostic sensitivities ranging from 76.4 to 97.2%, specificities ranging from 86.2 to 100.0%, and accuracies ranging from 80.9 to 90.7%. Sagittal-lung CT measurements allow for differentiating patients with ACOS from those with pure COPD. The ACOS patients had larger post-BD variations of sagittal-lung CT measurements than patients with pure COPD.

  5. An implemented MRI program to eliminate radiation from the evaluation of pediatric appendicitis.

    PubMed

    Kulaylat, Afif N; Moore, Michael M; Engbrecht, Brett W; Brian, James M; Khaku, Aliasgher; Hollenbeak, Christopher S; Rocourt, Dorothy V; Hulse, Michael A; Olympia, Robert P; Santos, Mary C; Methratta, Sosamma T; Dillon, Peter W; Cilley, Robert E

    2015-08-01

    Recent efforts have been directed at reducing ionizing radiation delivered by CT scans to children in the evaluation of appendicitis. MRI has emerged as an alternative diagnostic modality. The clinical outcomes associated with MRI in this setting are not well-described. Review of a 30-month institutional experience with MRI as the primary diagnostic evaluation for suspected appendicitis (n=510). No intravenous contrast, oral contrast, or sedation was administered. Radiologic and clinical outcomes were abstracted. MRI diagnostic characteristics were: sensitivity 96.8% (95% CI: 92.1%-99.1%), specificity 97.4% (95% CI: 95.3-98.7), positive predictive value 92.4% (95% CI: 86.5-96.3), and negative predictive value 98.9% (95% CI: 97.3%-99.7%). Radiologic time parameters included: median time from request to scan, 71 minutes (IQR: 51-102), imaging duration, 11 minutes (IQR: 8-17), and request to interpretation, 2.0 hours (IQR: 1.6-2.6). Clinical time parameters included: median time from initial assessment to admit order, 4.1 hours (IQR: 3.1-5.1), assessment to antibiotic administration 4.7 hours (IQR: 3.9-6.7), and assessment to operating room 9.1 hours (IQR: 5.8-12.7). Median length of stay was 1.2 days (range: 0.2-19.5). Given the diagnostic accuracy and favorable clinical outcomes, without the potential risks of ionizing radiation, MRI may supplant the role of CT scans in pediatric appendicitis imaging. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. [Quality assurance of rapid on-site evaluation of CT-guided fine-needle aspiration cytology of lung nodules].

    PubMed

    Bak, Mihály; Hidvégi, Judit; Andi, Judit; Bahéry, Mária; Kovács, Eszter; Schneider, Ferenc; Kostic, Szilárd; Rényi-Vámos, Ferenc; Szőke, János; Nyári, Tibor; Gődény, Mária; Kásler, Miklós

    2013-01-06

    The methods available for the diagnosis of lung cancer include radiologic, cytologic and pathologic procedures. The aim of this study was to determine the quality assurance of CT guided fine needle aspiration cytology of lung nodules. Cytology results were rated to 4 categories (positive; suspicious; negative; not representative). All cytology reports were compared with the final histology diagnosis. A total of 128 patients underwent CT-guided percutaneous fine-needle aspiration biopsy cytology (63 males; 65 females; mean age 62.8 years). Smears were adequate in 99 cases and inadequate in 29 cases. The average diameter of the nodules was 3.28 cm. Thirty three (25.6%) of the cases were histologically verified and 2 falsely negative and 2 falsely positive cases were detected. The sensitivity and the positive predictive value were 88.8% and 88.8%, respectively. Pneumothorax developed in 7 (5.4%) cases. These results suggest that CT-guided transthoracic fine needle aspiration cytology has a high diagnostic accuracy and an acceptable complication rate. The auditing valves of the results meet the proposed threshold values.

  7. SPECT/CT in patients with lower back pain after lumbar fusion surgery.

    PubMed

    Sumer, Johannes; Schmidt, Daniela; Ritt, Philipp; Lell, Michael; Forst, Raimund; Kuwert, Torsten; Richter, Richard

    2013-10-01

    The aim of the study was to investigate the incremental diagnostic value of skeletal hybrid imaging with single-photon emission computed tomography and X-ray computed tomography (SPECT/CT) over conventional nuclear medical imaging in patients with lower back pain after lumbar fusion surgery (LFS). This retrospective study comprised 37 patients suffering from lower back pain after LFS in whom three-phase planar bone scintigraphies of the lumbar spine including SPECT/CT of that region had been performed. The findings visible on these imaging data sets were classified into the following five diagnostic categories: (a) metal loosening; (b) insufficient stabilizing function of the metal implants indicated by metabolically active facet joint arthritis and/or intervertebral osteochondrosis in the instrumented region; (c) adjacent instability defined as metabolically active degenerative disease in the segments adjacent to the instrumented region; (d) indeterminate; and (e) normal. In the case of eight patients no lesions were visible on their planar scintigraphy and SPECT (planar/SPECT) or SPECT/CT images. In the remaining 29 patients, planar/SPECT disclosed 62 pathological foci of uptake within the graft region and SPECT/CT revealed 55. The rate of reclassification by SPECT/CT compared with planar/SPECT was 5/12 for lesions categorized as metal loosening by planar/SPECT, 16/29 for foci with a planar/SPECT diagnosis of insufficient stabilizing function, 7/20 when the planar/SPECT diagnosis had been adjacent instability, and 1/1 for the lesions indeterminate on planar/SPECT. Two lesions had been detected on SPECT/CT only. The overall rate of reclassification was 45.2% (28/62) (95% confidence interval, 33.4-57.5%). Because of its significantly higher accuracy compared with planar/SPECT, SPECT/CT should be the conventional nuclear medical procedure of choice for patients with lower back pain after LFS.

  8. Diagnostic Performance of Ultrafast Brain MRI for Evaluation of Abusive Head Trauma.

    PubMed

    Kralik, S F; Yasrebi, M; Supakul, N; Lin, C; Netter, L G; Hicks, R A; Hibbard, R A; Ackerman, L L; Harris, M L; Ho, C Y

    2017-04-01

    MR imaging with sedation is commonly used to detect intracranial traumatic pathology in the pediatric population. Our purpose was to compare nonsedated ultrafast MR imaging, noncontrast head CT, and standard MR imaging for the detection of intracranial trauma in patients with potential abusive head trauma. A prospective study was performed in 24 pediatric patients who were evaluated for potential abusive head trauma. All patients received noncontrast head CT, ultrafast brain MR imaging without sedation, and standard MR imaging with general anesthesia or an immobilizer, sequentially. Two pediatric neuroradiologists independently reviewed each technique blinded to other modalities for intracranial trauma. We performed interreader agreement and consensus interpretation for standard MR imaging as the criterion standard. Diagnostic accuracy was calculated for ultrafast MR imaging, noncontrast head CT, and combined ultrafast MR imaging and noncontrast head CT. Interreader agreement was moderate for ultrafast MR imaging (κ = 0.42), substantial for noncontrast head CT (κ = 0.63), and nearly perfect for standard MR imaging (κ = 0.86). Forty-two percent of patients had discrepancies between ultrafast MR imaging and standard MR imaging, which included detection of subarachnoid hemorrhage and subdural hemorrhage. Sensitivity, specificity, and positive and negative predictive values were obtained for any traumatic pathology for each examination: ultrafast MR imaging (50%, 100%, 100%, 31%), noncontrast head CT (25%, 100%, 100%, 21%), and a combination of ultrafast MR imaging and noncontrast head CT (60%, 100%, 100%, 33%). Ultrafast MR imaging was more sensitive than noncontrast head CT for the detection of intraparenchymal hemorrhage ( P = .03), and the combination of ultrafast MR imaging and noncontrast head CT was more sensitive than noncontrast head CT alone for intracranial trauma ( P = .02). In abusive head trauma, ultrafast MR imaging, even combined with noncontrast head CT, demonstrated low sensitivity compared with standard MR imaging for intracranial traumatic pathology, which may limit its utility in this patient population. © 2017 by American Journal of Neuroradiology.

  9. Analysis of clinical value of CT in the diagnosis of pediatric pneumonia and mycoplasma pneumonia.

    PubMed

    Gong, Liang; Zhang, Chong-Lin; Zhen, Qing

    2016-04-01

    Pneumonia is an infectious disease of the lung causing mortality. Mycoplasma pneumonia (MP) is an atypical bacterial pneumonia that damages several organs. Lung computed tomography (CT) has been utilized in its identification. The aim of the present study was to examine the value of computed tomography diagnosis for pediatric MP. The present study prospectively analyzed the clinical and imaging data of 1,280 cases of pediatric MP in the out- and inpatient departments from March, 2010 to March, 2014; analyzed the morphology and distribution of the pneumonic lesion in the lungs; and summarized the value of CT diagnosis for pediatric MP. In the included children, there were 688 cases of lesions in the unilateral lobe, 592 cases of lesions in the bilateral lobes, 1,101 cases of extensive patchy opacity, 496 cases of mottled opacity, 432 cases of increased lung marking, 256 cases of streak opacity, 192 cases of ground-glass opacity, 992 cases of thickened bronchial wall in the lesions, 128 cases of lymphadenopathy in the hilar lymph nodes and mediastinal lymph nodes, and the lung CT showed 32 cases of pulmonary cavity and 144 cases of pleural effusion. In conclusion, the CT signals of pediatric MP had several types with some children exhibiting complicated changes. The child's clinical manifestation and symptoms should thus be considered in the diagnosis to improve the diagnostic rate.

  10. Diagnostic Ability of FDG-PET/CT in the Detection of Malignant Pleural Effusion

    PubMed Central

    Nakajima, Reiko; Abe, Koichiro; Sakai, Shuji

    2015-01-01

    Abstract We investigated the role of F-18 fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) for the differential diagnosis of malignant and benign pleural effusion. We studied 36 consecutive patients with histologically proven cancer (excluding malignant mesothelioma) who underwent FDG-PET/CT for suspected malignant pleural effusion. Fourteen patients had cytologically proven malignant pleural effusion and the other 22 patients had either negative cytology or clinical follow-up, which confirmed the benign etiology. We examined the maximum standardized uptake values (SUVmax) of pleural effusion and the target-to-normal tissue ratio (TNR), calculated as the ratio of the pleural effusion SUVmax to the SUVmean of the normal tissues (liver, spleen, 12th thoracic vertebrae [Th12], thoracic aorta, and spinalis muscle). We also examined the size and density (in Hounsfield units) of the pleural effusion and pleural abnormalities on CT images. TNR (Th12) and increased pleural FDG uptake compared to background blood pool were significantly more frequent in cases with malignant pleural effusion (P < 0.05 for both). The cutoff TNR (Th12) value of >0.95 was the most accurate; the sensitivity, specificity, and accuracy for this value were 93%, 68%, and 75%, respectively. FDG-PET/CT can be a useful method for the differential diagnosis of malignant and benign pleural effusion. PMID:26200610

  11. CT fluoroscopy-guided renal tumour cutting needle biopsy: retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure.

    PubMed

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu

    2018-01-01

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. • CT fluoroscopy-guided renal tumour biopsy has a high diagnostic yield. • CT fluoroscopy-guided renal tumour biopsy is safe. • Small tumour size (≤1.5 cm) is a risk factor for diagnostic failure.

  12. Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szczykutowicz, Timothy P., E-mail: tszczykutowicz@uwhealth.org; Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705; Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706

    2016-02-15

    Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribedmore » gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.« less

  13. Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease.

    PubMed

    Gao, Wei; Zhong, Yu Min; Sun, Ai Min; Wang, Qian; Ouyang, Rong Zhen; Hu, Li Wei; Qiu, Han Sheng; Wang, Shi Yu; Li, Jian Ying

    2016-06-01

    To explore the clinical value and evaluate the diagnostic accuracy of sub-mSv low-dose prospective ECG-triggering cardiac CT (CCT) in young infants with complex congenital heart disease (CHD). A total of 102 consecutive infant patients (53 boys and 49 girls with mean age of 2.9 ± 2.4 m and weight less than 5 kg) with complex CHD were prospectively enrolled. Scans were performed on a 64-slice high definition CT scanner with low dose prospective ECG-triggering mode and reconstructed with 80 % adaptive statistical iterative reconstruction algorithm. All studies were performed during free breathing with sedation. The subjective image quality was evaluated by 5-point grading scale and interobserver variability was calculated. The objective image noise (standard deviation, SD) and contrast to noise ratio (CNR) was calculated. The effective radiation dose from the prospective ECG-triggering mode was recorded and compared with the virtual conventional retrospective ECG-gating mode. The detection rate for the origin of coronary artery was calculated. All patients also underwent echocardiography before CCT examination. 81 patients had surgery and their preoperative CCT and echocardiography findings were compared with the surgical results and sensitivity, specificity, positive and negative predictive values and accuracy were calculated for separate cardiovascular anomalies. Heart rates were 70-161 beats per minute (bpm) with mean value of 129.19 ± 14.52 bpm. The effective dose of 0.53 ± 0.15 mSv in the prospective ECG-triggering cardiac CT was lower than the calculated value in a conventional retrospective ECG-gating mode (2.00 ± 0.35 mSv) (p < 0.001). The mean CNR and SD were 28.19 ± 13.00 and 15.75 ± 3.61HU, respectively. The image quality scores were 4.31 ± 0.36 and 4.29 ± 0.41 from reviewer 1 and 2 respectively with an excellent agreement between them (Kappa = 0.85). The detection rate for the origins of the left and right coronary arteries was 96 and 90 %, respectively. The detection rates of the origins of left coronary artery and right coronary artery in all cases were 96 % (78/81) and 90 % (73/81), respectively. Twenty cases of conotruncal anomalies and ALCAPA were validated surgically and the accuracy of cardiac CT diagnosis was 95 % (19/20). The overall deformity based sensitivity, specificity, positive predictive value and negative predictive value were 94.0.1, 99.9, 98.6, 99.5 % respectively, by CCT, and 88.2, 99.9, 97.8, 99.0 %, respectively, by echocardiography. Prospective ECG-triggering CCT with sub-mSv effective dose provides excellent imaging quality and high diagnostic accuracy for young infants with complex CHD.

  14. Thoracoabdominal Computed Tomography in Trauma Patients: A Cost-Consequences Analysis

    PubMed Central

    van Vugt, Raoul; Kool, Digna R.; Brink, Monique; Dekker, Helena M.; Deunk, Jaap; Edwards, Michael J.

    2014-01-01

    Background: CT is increasingly used during the initial evaluation of blunt trauma patients. In this era of increasing cost-awareness, the pros and cons of CT have to be assessed. Objectives: This study was performed to evaluate cost-consequences of different diagnostic algorithms that use thoracoabdominal CT in primary evaluation of adult patients with high-energy blunt trauma. Materials and Methods: We compared three different algorithms in which CT was applied as an immediate diagnostic tool (rush CT), a diagnostic tool after limited conventional work-up (routine CT), and a selective tool (selective CT). Probabilities of detecting and missing clinically relevant injuries were retrospectively derived. We collected data on radiation exposure and performed a micro-cost analysis on a reference case-based approach. Results: Both rush and routine CT detected all thoracoabdominal injuries in 99.1% of the patients during primary evaluation (n = 1040). Selective CT missed one or more diagnoses in 11% of the patients in which a change of treatment was necessary in 4.8%. Rush CT algorithm costed € 2676 (US$ 3660) per patient with a mean radiation dose of 26.40 mSv per patient. Routine CT costed € 2815 (US$ 3850) and resulted in the same radiation exposure. Selective CT resulted in less radiation dose (23.23 mSv) and costed € 2771 (US$ 3790). Conclusions: Rush CT seems to result in the least costs and is comparable in terms of radiation dose exposure and diagnostic certainty with routine CT after a limited conventional work-up. However, selective CT results in less radiation dose exposure but a slightly higher cost and less certainty. PMID:25337521

  15. Diagnostic test accuracy study of 18F-sodium fluoride PET/CT, 99mTc-labelled diphosphonate SPECT/CT, and planar bone scintigraphy for diagnosis of bone metastases in newly diagnosed, high-risk prostate cancer

    PubMed Central

    Fonager, Randi F; Zacho, Helle D; Langkilde, Niels C; Fledelius, Joan; Ejlersen, June A; Haarmark, Christian; Hendel, Helle W; Lange, Mine Benedicte; Jochumsen, Mads R; Mortensen, Jesper C; Petersen, Lars J

    2017-01-01

    The aim of this study was to prospectively compare planar, bone scan (BS) versus SPECT/CT and NaF PET/CT in detecting bone metastases in prostate cancer. Thirty-seven consecutive, newly diagnosed, prostate cancer patients with prostate specific antigen (PSA) levels ≥ 50 ng/mL and who were considered eligible for androgen-deprivation therapy (ADT) were included in this study. BS, SPECT/CT, and NaF PET/CT, were performed prior to treatment and were repeated after six months of ADT. Baseline images from each index test were independently read by two experienced readers. The reference standard was based on a consensus decision made by a multidisciplinary team on the basis of baseline and follow-up images of the index tests, the findings of the baseline index tests by the experienced readers, and any available imaging, biochemical, and clinical data, including the response to ADT. Twenty-seven (73%) of the 37 patients had bone metastases according to the reference standard. The sensitivities for BS, SPECT/CT and NaF PET/CT were 78%, 89%, and 89%, respectively, and the specificities were 90%, 100%, and 90%, respectively. The positive predictive values of BS, SPECT/CT and NaF PET/CT were 96%, 100%, and 96%, respectively, and the negative predictive values were 60%, 77% and 75%, respectively. No statistically significant difference among the three imaging modalities was observed. All three imaging modalities showed high sensitivity and specificity. NaF PET/CT and SPECT/CT showed numerically improved, but not statistically superior, sensitivity compared with BS in this limited and selected patient cohort. PMID:29181269

  16. Single-phase Whole-body 64-MDCT Split-bolus Protocol for Pediatric Oncology: Diagnostic Efficacy and Dose Radiation.

    PubMed

    Scialpi, Michele; Schiavone, Raffaele; D'Andrea, Alfredo; Palumbo, Isabella; Magli, Michelle; Gravante, Sabrina; Falcone, Giuseppe; De Filippi, Claudio; Manganaro, Lucia; Palumbo, Barbara

    2015-05-01

    To evaluate the image quality and the diagnostic efficacy by single-phase whole-body 64-slice multidetector CT (MDCT) for pediatric oncology. Chest-abdomen-pelvis CT examinations with single-phase split-bolus technique were evaluated for T: detection and delineation of primary tumor (assessment of the extent of the lesion to neighboring tissues), N: regional lymph nodes and M: distant metastasis. Quality scores (5-point scale) were assessed by two radiologists on parenchymal and vascular enhancement. Accurate TNM staging in term of detection and delineation of primary tumor, regional lymph nodes and distant metastasis was obtained in all cases. On the image quality and severity artifact, the Kappa value for the interobserver agreement measure obtained from the analysis was 0.754, (p<0.001), characterizing a very good agreement between observers. Single-pass total body CT split-bolus technique reached the highest overall image quality and an accurate TNM staging in pediatric patients with cancer. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  17. Fiber optic video monitoring system for remote CT/MR scanners clinically accepted

    NASA Astrophysics Data System (ADS)

    Tecotzky, Raymond H.; Bazzill, Todd M.; Eldredge, Sandra L.; Tagawa, James; Sayre, James W.

    1992-07-01

    With the proliferation of CT travel to distant scanners to review images before their patients can be released. We designed a fiber-optic broadband video system to transmit images from seven scanner consoles to fourteen remote monitoring stations in real time. This system has been used clinically by radiologists for over one years. We designed and conducted a user survey to categorize the levels of system use by section (Chest, GI, GU, Bone, Neuro, Peds, etc.), to measure operational utilization and acceptance of the system into the clinical environment, to clarify the system''s importance as a clinical tool for saving radiologists travel-time to distant CT the system''s performance and limitations as a diagnostic tool. The study was administered directly to radiologists using a printed survey form. The results of the survey''s compiled data show a high percentage of system usage by a wide spectrum of radiologists. Clearly, this system has been accepted into the clinical environment as a highly valued diagnostic tool in terms of time savings and functional flexibility.

  18. Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

    PubMed

    Schueler, Sabine; Walther, Stefan; Schuetz, Georg M; Schlattmann, Peter; Dewey, Marc

    2013-06-01

    To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item ("Uninterpretable Results") showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with "no fulfilment" increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. • Good methodological quality is a basic requirement in diagnostic accuracy studies. • Most coronary CT angiography studies have only been of moderate design quality. • Weak methodological quality will affect the sensitivity and specificity. • No improvement in methodological quality was observed over time. • Authors should consider the QUADAS checklist when undertaking accuracy studies.

  19. Value of ¹⁸F-FDG PET/CT in the diagnosis of primary gastric cancer via stomach distension.

    PubMed

    Ma, Quanmei; Xin, Jun; Zhao, Zhoushe; Guo, Qiyong; Yu, Shupeng; Xu, Weina; Liu, Changping; Zhai, Wei

    2013-06-01

    To clarify the usefulness of (18)F-FDG PET/CT for detecting primary gastric cancer via gastric distention using a mixture of milk and Diatrizoate Meglumine. A total of 68 patients (male: 47, female: 21; age: 41-87 years) suspected of gastric carcinoma underwent (18)F-FDG PET/CT imaging. After whole-body PET/CT imaging in a fasting state, the patients drank a measured amount of milk with Diatrizoate Meglumine. Local gastric district PET/CT imaging was performed 30 min later. The imaging was analyzed by semi-quantitative analysis, standardized uptake value (SUV) of the primary tumor was measured in a region of interest. The diagnosis results were confirmed by gastroscopy, pathology, and follow-up results. Of the 68 patients, 56 malignant gastric neoplasm patients (male: 37, female: 19) were conformed. The sensitivity, specificity, positive predictive value and negative predictive value of fasting whole-body PET/CT imaging for a primary malignant tumor were 92.9%, 75.0%, 94.5%, and 69.0%, respectively. The values for distension with a mixture of milk and Diatrizoate Meglumine were 91.1%, 91.7%, 98.1%, and 68.8%, respectively. The area under the curve was 0.919 ± 0.033 and 0.883 ± 0.066 for the diagnosis of gastric cancer with SUVmax in a fasting state and after intake of mixture respectively, the differences were not statistically significant (P=0.359). Using gastric distension with a mixture of milk and Diatrizoate Meglumine, the mean ratio of the lesion's SUVmax to the adjacent gastric wall SUVmax increased significantly from 3.30 ± 3.05 to 13.50 ± 15.05, which was statistically significant (P<0.001). (18)F-FDG PET/CT imaging is highly accurate for the diagnosis of primary gastric carcinoma. Gastric distention can display the lesions more clearly, however, it cannot significantly improve diagnostic accuracy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. Biopsy of CT-Occult Bone Lesions Using Anatomic Landmarks for CT Guidance.

    PubMed

    Hillen, Travis J; Talbert, Robert J; Friedman, Michael V; Long, Jeremiah R; Jennings, Jack W; Wessell, Daniel E; Baker, Jonathan C

    2017-07-01

    The purpose of this study is to evaluate the histopathologic diagnostic yield, sample size, procedural time, and dose-length product (DLP) for the biopsy of CT-occult lesions found at MRI or PET or both. A retrospective review of our radiology information system for biopsies of CT-occult lesions using CT guidance from January 1, 2010, through December 31, 2014, was performed and compared with a selection of CT-guided biopsies of CT-evident bone lesions during the same period. The data were then evaluated for diagnostic yield of histopathologic diagnosis, procedural time, use of sedation medication, DLP, and size of specimens obtained. A total of 30 CT-occult biopsies met the inclusion criteria. Twenty-seven of those biopsies had results that were concordant with the patient's primary histopathologic diagnosis, imaging findings, and clinical course. In the CT-evident lesion group, concordant histopathologic abnormalities were identified in 27 of 30 patients. There was a statistically significant increase in number of samples obtained for the CT-evident lesions compared with CT-occult lesions. There was no statistically significant difference in total specimen length, DLP, number of CT scans, procedural time, or use of sedation medication between the CT-occult and CT-evident biopsy groups. Biopsy of CT-occult lesions using anatomic landmarks achieves diagnostic yields similar to those for CT-guided biopsy of CT-evident lesions.

  1. Diagnostic accuracy of sequential co-registered PET+MR in comparison to PET/CT in local thoracic staging of malignant pleural mesothelioma.

    PubMed

    Martini, Katharina; Meier, Andreas; Opitz, Isabelle; Weder, Walter; Veit-Haibach, Patrick; Stahel, Rolf A; Frauenfelder, Thomas

    2016-04-01

    To investigate the diagnostic accuracy of sequential co-registered PET+MR (PET+MR) for local staging of malignant pleural mesothelioma (MPM) compared to PET/CT. In a prospective clinical trial 34 consecutive patients (median age 66 years; range 40-79 years; 1 female, 33 male) with known MPM, who underwent PET/CT and PET+MR exams for either staging or re-staging/follow-up were evaluated. Imaging was conducted using a tri-modality PET/CT-MR set-up (Discovery PET/CT 690, 3T Discovery MR 750w, both GE Healthcare, Waukesha, WI, USA). In 26 cases histopathology served as standard of reference. Two independent readers evaluated images for T and N stage, confidence level (sure to unsure; 1-3) and subjective overall image quality (very good to non-diagnostic; 1-4). Inter-observer agreement of T and N stages (Cohen's kappa) and interclass correlation coefficient (ICC) between PET/CT vs. PET+MR was calculated. Inter observer agreement for evaluation of T and N Stage in PET/CT images was excellent (k=0.844 and k=0.824, respectively), whereas PET+MR imaging showed substantial agreement in T and N stage (k=0.729 and k=0.691, respectively). The ICC of PET/CT vs. PET+MR for evaluation of both, T and N Stage, was excellent (ICC=0.951 and ICC=0.93, respectively). Diagnostic confidence was scored significantly higher in PET+MR compared to PET/CT (mean score=1.66 and 1.93, respectively; p=0.004). Image quality was diagnostic for all image series. Comparing pT and pN stage vs cT and cN stage (n=26 cases), both imaging modalities showed excellent agreement for T stage (ICCPET+MR=0.888 vs. ICCPET/CT=0.853, respectively) and substantial to moderate agreement for N stage (ICCPET+MR=0.683 vs. ICC=0.595PET/CT, respectively). Our findings suggest that diagnostic accuracy of PET+MR is comparable to PET/CT for local staging of MPM, whereas radiologists felt significantly more confident staging PET+MR compared to PET/CT images (p=0003), using dedicated sequences. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Radiological diagnosis in lung disease: factoring treatment options into the choice of diagnostic modality.

    PubMed

    Wielpütz, Mark O; Heußel, Claus P; Herth, Felix J F; Kauczor, Hans-Ulrich

    2014-03-14

    Chest X-ray, computed tomography (CT), and magnetic resonance imaging (MRI) each have characteristic advantages and disadvantages that need to be considered in clinical decision-making. This point is discussed in reference to the main types of lung disease that are encountered in practice. A selective literature search was performed in the PubMed and Google Scholar databases. Existing clinical guidelines on the main types of lung disease and studies concerning radiological diagnosis were also con - sidered in this review. There have been no more than a few large-scale, controlled comparative trials of different radiological techniques. Chest X-ray provides general orientation as an initial diagnostic study and is especially useful in the diagnosis of pneumonia, cancer, and chronic obstructive pulmonary disease (COPD). Multi-detector CT affords nearly isotropic spatial resolution at a radiation dose of only 0.2-5 mSv, much lower than before. Its main indications, according to current guidelines, are tumors, acute pulmonary embolism, pulmonary hypertension, pulmonary fibrosis, advanced COPD, and pneumonia in a high-risk patient. MRI is used in the diagnosis of cystic fibrosis, pulmonary embolism, pulmonary hypertension, and bronchial carcinoma. The positive predictive value (PPV) of a chest X-ray in outpatients with pneumonia is only 27% (gold standard, CT); in contrast, an initial, non-randomized trial of MRI in nosocomial pneumonia revealed a PPV of 95%. For the staging of mediastinal lymph nodes in bronchial carcinoma, MRI has a PPV of 88% and positron emission tomography with CT (PET/CT) has a PPV of 79%, while CT alone has a PPV of 41% (gold standard, histology). The choice of radiologicalal technique for the detection, staging, follow-up, and quantification of lung disease should be based on the individual clinical options, so that appropriate treatment can be provided without excessive use of diagnostic testing.

  3. Age-Related Differences in Diagnostic Accuracy of Plasma GFAP and Tau For Identifying Acute Intracranial Trauma on CT: A TRACK-TBI Study.

    PubMed

    Gardner, Raquel C; Rubenstein, Richard; Wang, Kevin K W; Korley, Frederick Kofi; Yue, John K; Yuh, Esther Lim; Mukherjee, Pratik; Valadka, Alex; Okonkwo, David O; Diaz-Arrastia, Ramon; Manley, Geoffrey

    2018-05-02

    Plasma tau and glial fibrillary acidic protein (GFAP) are promising biomarkers for identifying traumatic brain injury (TBI) patients with intracranial trauma on CT. Accuracy in older adults with mild TBI (mTBI), the fastest growing TBI population, is unknown. Our aim was to assess for age-related differences in diagnostic accuracy of plasma tau and GFAP for identifying intracranial trauma on CT. Samples from 169 patients (age <40y [n=79], age 40-59y [n=60], age 60y+ [n=30]), a subset of patients from the TRACK-TBI Pilot study, who presented with mTBI (GCS 13-15), received head CT, and consented to blood-draw within 24h of injury were assayed for hyperphosphorylated-tau (P-tau), total-tau (T-tau; both via amplification-linked enhanced immunoassay using multi-arrayed fiberoptics), and GFAP (via sandwich enzyme-linked immunosorbent assay). P-tau, T-tau, P-tau:T-tau ratio, and GFAP concentration were significantly associated with CT findings. Overall, discriminative ability declined with increasing age for all assays, but this decline was only statistically significant for GFAP (area under the receiver operating characteristic curve [AUC]: old 0.73[ref] vs. young 0.93[p=0.037] or middle-aged 0.92[p<0.050]). P-tau concentration showed consistently highest diagnostic accuracy across all age-groups (AUC: old 0.84[ref] vs. young 0.95[p=0.274] or middle-aged 0.93[p=0.367]). Comparison of models including P-tau alone versus P-tau plus GFAP revealed significant added value of GFAP. In conclusion, the GFAP assay was less accurate for identifying intracranial trauma on CT among older versus younger mTBI patients. Mechanisms of this age-related difference, including role of assay methodology, specific TBI neuroanatomy, pre-existing conditions, and anti-thrombotic use warrant further study.

  4. Trends in the utilization of computed tomography and cardiac catheterization among children with congenital heart disease.

    PubMed

    Yang, Justin Cheng-Ta; Lin, Ming-Tai; Jaw, Fu-Shan; Chen, Shyh-Jye; Wang, Jou-Kou; Shih, Tiffany Ting-Fang; Wu, Mei-Hwan; Li, Yiu-Wah

    2015-11-01

    Pediatric cardiac computed tomography (CT) is a noninvasive imaging modality used to clearly demonstrate the anatomical detail of congenital heart diseases. We investigated the impact of cardiac CT on the utilization of cardiac catheterization among children with congenital heart disease. The study sample consisted of 2648 cardiac CT and 3814 cardiac catheterization from 1999 to 2009 for congenital heart diseases. Diagnoses were categorized into 11 disease groups. The numbers of examination, according to the different modalities, were compared using temporal trend analyses. The estimated effective radiation doses (mSv) of CT and catheterization were calculated and compared. The number of CT scans and interventional catheterizations had a slight annual increase of 1.2% and 2.7%, respectively, whereas that of diagnostic catheterization decreased by 6.2% per year. Disease groups fell into two categories according to utilization trend differences between CT and diagnostic catheterization. The increased use of CT reduces the need for diagnostic catheterization in patients with atrioventricular connection disorder, coronary arterial disorder, great vessel disorder, septal disorder, tetralogy of Fallot, and ventriculoarterial connection disorder. Clinicians choose either catheterization or CT, or both examinations, depending on clinical conditions, in patients with semilunar valvular disorder, heterotaxy, myocardial disorder, pericardial disorder, and pulmonary vein disorder. The radiation dose of CT was lower than that of diagnostic cardiac catheterization in all age groups. The use of noninvasive CT in children with selected heart conditions might reduce the use of diagnostic cardiac catheterization. This may release time and facilities within the catheterization laboratory to meet the increasing demand for cardiac interventions. Copyright © 2014. Published by Elsevier B.V.

  5. Comparison of standard radiography and computed tomography in 21 dogs with maxillary masses.

    PubMed

    Ghirelli, Carolina O; Villamizar, Lenin A; Pinto, Ana Carolina B C Fonseca

    2013-01-01

    Imaging of patients with oral cancer is required to determine tumor extension in order to assist in prognosis and surgical planning. Conventional screen-film radiography (SFR) used to be the most common method for oral assessment, but computed tomography (CT) has become more available and is being used for obtaining complementary information. CT examinations eliminate superimposition by acquiring cross-sectional images of the region of interest. The objective of this study was to determine the diagnostic value of SFR compared with CT examinations for evaluation of oral masses in dogs. Twenty-one dogs received head and thorax SFR, and pre- and post-contrast head CT. Bony changes were observed in 80.9% and 95.2% of the cases in SFR and CT studies, respectively. Invasion of adjacent structures (i.e. nasal cavity, frontal and sphenoidal sinuses, orbit, maxillary recess, nasopharynx) was observed in only 30% of cases with SFR while CT showed 90.4% involvement. CT is an important preoperative examination modality and is more effective in identifying bone changes and tumor invasion of adjacent structures compared with SFR.

  6. The diagnostic performance of CT-derived fractional flow reserve for evaluation of myocardial ischaemia confirmed by invasive fractional flow reserve: a meta-analysis.

    PubMed

    Li, S; Tang, X; Peng, L; Luo, Y; Dong, R; Liu, J

    2015-05-01

    To review the literature on the diagnostic accuracy of CT-derived fractional flow reserve (FFRCT) for the evaluation of myocardial ischaemia in patients with suspected or known coronary artery disease, with invasive fractional flow reserve (FFR) as the reference standard. A PubMed, EMBASE, and Cochrane cross-search was performed. The pooled diagnostic accuracy of FFRCT, with FFR as the reference standard, was primarily analysed, and then compared with that of CT angiography (CTA). The thresholds to diagnose ischaemia were FFR ≤0.80 or CTA ≥50% stenosis. Data extraction, synthesis, and statistical analysis were performed by standard meta-analysis methods. Three multicentre studies (NXT Trial, DISCOVER-FLOW study and DeFACTO study) were included, examining 609 patients and 1050 vessels. The pooled sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR) for FFRCT were 89% (85-93%), 71% (65-75%), 70% (65-75%), 90% (85-93%), 3.31 (1.79-6.14), 0.16 (0.11-0.23), and 21.21 (9.15-49.15) at the patient-level, and 83% (78-63%), 78% (75-81%), 61% (56-65%), 92% (89-90%), 4.02 (1.84-8.80), 0.22 (0.13-0.35), and 19.15 (5.73-63.93) at the vessel-level. At per-patient analysis, FFRCT has similar sensitivity but improved specificity, PPV, NPV, LR+, LR-, and DOR versus those of CTA. At per-vessel analysis, FFRCT had a slightly lower sensitivity, similar NPV, but improved specificity, PPV, LR+, LR-, and DOR compared with those of CTA. The area under the summary receiver operating characteristic curves for FFRCT was 0.8909 at patient-level and 0.8865 at vessel-level, versus 0.7402 for CTA at patient-level. FFRCT, which was associated with improved diagnostic accuracy versus CTA, is a viable alternative to FFR for detecting coronary ischaemic lesions. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. CT vs. MRCP in choledocholithiasis jaundice.

    PubMed

    Petrescu, I; Bratu, A M; Petrescu, S; Popa, B V; Cristian, D; Burcos, T

    2015-01-01

    Obstructive jaundice can raise problems to diagnostic imaging. The radiologist must choose the most appropriate examination that delivers the most important diagnostic information because the differences between a lithiasic obstruction and a tumoral one are vital. This information helps the surgeon speed up the process of decision-making, because the treatment may be very different in relation to the nature of the obstruction. This study tries to demonstrate the diagnostic accuracy of computed tomography (CT) and magnetic resonance cholangiopancreatography (MRCP) in detecting the obstacle in the common bile duct (CBD) and the possibility of establishing the lithiasic nature of the obstruction. A retrospective analysis was analyzed during an interval of 18 months that included jaundice patients admitted in the General Surgery Department of "Coltea" Clinical Hospital. They were examined by CT scanning and by MRCP, being suspected of choledocholithiasis. 63 patients were included in the study, 34 females and 29 males. 33 CT scans and 30 MRCP exams were performed. CT scan is useful in detecting residual or iterative choledocholithiasis in patients after cholecystectomy, contrast enhanced CT (CECT), being able to differentiate between lithiasic and non-lithiasic obstruction. MRCP delivers important anatomic details of the biliary tree; it is superior to CT in diagnosing the hepatocholedochal lithiasis; MRCP tends to replace endoscopic retrograde cholangiopancreatography (ERCP)--the diagnostic "gold standard" reducing the number of unnecessary invasive diagnostic procedures.

  8. Clinical Value of FDG-PET/CT for the Evaluation of Rheumatic Diseases: Rheumatoid Arthritis, Polymyalgia Rheumatica, and Relapsing Polychondritis.

    PubMed

    Kubota, Kazuo; Yamashita, Hiroyuki; Mimori, Akio

    2017-07-01

    FDG is a tracer for visualizing glucose metabolism. PET/CT using FDG is widely used for the diagnosis of cancer, because glycolysis is elevated in cancer cells. Similarly, active inflammatory tissue also exhibits elevated glucose metabolism because of glycolysis in activated macrophages and proliferating fibroblasts. Elevated FDG uptake by active inflammatory tissues, such as those affected by arthritis, vasculitis, lymphadenitis, and chondritis, has enabled the diagnosis of inflammatory diseases using FDG-PET/CT. Rheumatoid arthritis (RA) is a systemic, chronic inflammation of the joints resulting in synovitis. Several clinical studies of RA have demonstrated that FDG uptake in affected joints reflects the disease activity of RA, with strong correlations between FDG uptake and various clinical parameters having been noted. Furthermore, the use of FDG-PET for the sensitive detection and early monitoring of the response to RA therapy has been reported. RA is sometimes associated with subclinical vasculitis, which is related to systemic inflammation. FDG-PET/CT can be used to evaluate subclinical vasculitis in the aorta or carotid artery. Polymyalgia rheumatica (PMR) is an autoimmune musculoskeletal disease of unknown etiology characterized by pain and stiffness in the shoulder, neck, and pelvic girdle, but not in the small finger joints in the hands, together with fever, fatigue, and weight loss. There is no specific test for PMR, and its diagnosis is based on clinical diagnostic criteria and the exclusion of other diseases with similar symptoms. However, FDG-PET/CT reveals a characteristic FDG uptake by the bursitis in ischial tuberosity, greater trochanter, lumbar or cervical spinous process, and scapulohumeral joint. A combination of FDG-PET/CT findings showed a high diagnostic value for PMR in a differential diagnosis from RA. FDG-PET/CT is also very useful for evaluating large vessel vasculitis, which is often associated with PMR. Relapsing polychondritis is a rare multisystem disease of unknown etiology involving cartilaginous and proteoglycan-rich structures. Its rarity and diversity of symptoms often result in a delayed diagnosis. FDG-PET/CT reveals unique FDG uptake findings for chondritis in the auricular, nasal, trachea, bronchial tree, and costal cartilage and in the cartilage of joints. Thus, the spread of knowledge regarding these very specific FDG-PET/CT findings could promote the early diagnosis and improved disease control of relapsing polychondritis. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. The Accuracy of Urinalysis in Predicting Intra-Abdominal Injury Following Blunt Traumas.

    PubMed

    Sabzghabaei, Anita; Shojaee, Majid; Safari, Saeed; Hatamabadi, Hamid Reza; Shirvani, Reza

    2016-01-01

    In cases of blunt abdominal traumas, predicting the possible intra-abdominal injuries is still a challenge for the physicians involved with these patients. Therefore, this study was designed, to evaluate the accuracy of urinalysis in predicting intra-abdominal injuries. Patients aged 15 to 65 years with blunt abdominal trauma who were admitted to emergency departments were enrolled. Abdominopelvic computed tomography (CT) scan with intravenous contrast and urinalysis were requested for all the included patients. Demographic data, trauma mechanism, the results of urinalysis, and the results of abdominopelvic CT scan were gathered. Finally, the correlation between the results of abdominopelvic CT scan, and urinalysis was determined. Urinalysis was considered positive in case of at least one positive value in gross appearance, blood in dipstick, or red blood cell count. 325 patients with blunt abdominal trauma were admitted to the emergency departments (83% male with the mean age of 32.63±17.48 years). Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of urinalysis, were 77.9% (95% CI: 69.6-84.4), 58.5% (95% CI: 51.2-65.5), 56% (95% CI: 48.5-63.3), 79.6% (95% CI: 71.8-85.7), 1.27% (95% CI: 1.30-1.57), and 0.25% (95% CI: 0.18-0.36), respectively. The diagnostic value of urinalysis in prediction of blunt traumatic intra-abdominal injuries is low and it seems that it should be considered as an adjuvant diagnostic tool, in conjunction with other sources such as clinical findings and imaging.

  10. The Value of 18F-FDG PET/CT in Diagnosis and During Follow-up in 273 Patients with Chronic Q Fever.

    PubMed

    Kouijzer, Ilse J E; Kampschreur, Linda M; Wever, Peter C; Hoekstra, Corneline; van Kasteren, Marjo E E; de Jager-Leclercq, Monique G L; Nabuurs-Franssen, Marrigje H; Wegdam-Blans, Marjolijn C A; Ammerlaan, Heidi S M; Buijs, Jacqueline; Geus-Oei, Lioe-Fee de; Oyen, Wim J G; Bleeker-Rovers, Chantal P

    2018-01-01

    In 1%-5% of all acute Q fever infections, chronic Q fever develops, mostly manifesting as endocarditis, infected aneurysms, or infected vascular prostheses. In this study, we investigated the diagnostic value of 18 F-FDG PET/CT in chronic Q fever at diagnosis and during follow-up. Methods: All adult Dutch patients suspected of chronic Q fever who were diagnosed since 2007 were retrospectively included until March 2015, when at least one 18 F-FDG PET/CT scan was obtained. Clinical data and results from 18 F-FDG PET/CT at diagnosis and during follow-up were collected. 18 F-FDG PET/CT scans were prospectively reevaluated by 3 nuclear medicine physicians using a structured scoring system. Results: In total, 273 patients with possible, probable, or proven chronic Q fever were included. Of all 18 F-FDG PET/CT scans performed at diagnosis, 13.5% led to a change in diagnosis. Q fever-related mortality rate in patients with and without vascular infection based on 18 F-FDG PET/CT was 23.8% and 2.1%, respectively ( P = 0.001). When 18 F-FDG PET/CT was added as a major criterion to the modified Duke criteria, 17 patients (1.9-fold increase) had definite endocarditis. At diagnosis, 19.6% of 18 F-FDG PET/CT scans led to treatment modification. During follow-up, 57.3% of 18 F-FDG PET/CT scans resulted in treatment modification. Conclusion: 18 F-FDG PET/CT is a valuable technique in diagnosis of chronic Q fever and during follow-up, often leading to a change in diagnosis or treatment modification and providing important prognostic information on patient survival. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  11. Diagnostic Value of 68Ga PSMA-11 PET/CT Imaging of Brain Tumors-Preliminary Analysis.

    PubMed

    Sasikumar, Arun; Joy, Ajith; Pillai, M R A; Nanabala, Raviteja; Anees K, Muhammed; Jayaprakash, P G; Madhavan, Jayaprakash; Nair, Suresh

    2017-01-01

    To evaluate the feasibility of using Ga PSMA-11 PET/CT for imaging brain lesions and its comparison with F-FDG. Ten patients with brain lesions were included in the study. Five patients were treated cases of glioblastoma with suspected recurrence. F-FDG and Ga PSMA-11 brain scans were done for these patients. Five patients were sent for assessing the nature (primary lesion/metastasis) of space occupying lesion in brain. They underwent whole body F-FDG PET/CT scan and a primary site elsewhere in the body was ruled out. Subsequently they underwent Ga PSMA-11 brain PET/CT imaging. Target to background ratios (TBR) for the brain lesions were calculated using contralateral cerebellar uptake as background. In five treated cases of glioblastoma with suspected recurrence the findings of Ga PSMA-11 PET/CT showed good correlation with that of F-FDG PET/CT scan. Compared to the F-FDG, Ga PSMA-11 PET/CT showed better visualization of the recurrent lesion (presence/absence) owing to its significantly high TBR. Among the five cases evaluated for lesion characterization glioma and atypical meningioma patients showed higher SUVmax in the lesion with Ga PSMA-11 than with F-FDG and converse in cases of lymphoma. TBR was better with Ga PSMA PET/CT in all cases. Ga PSMA-11 PET/CT brain imaging is a potentially useful imaging tool in the evaluation of brain lesions. Absence of physiological uptake of Ga PSMA-11 in the normal brain parenchyma results in high TBR values and consequently better visualization of metabolically active disease in brain.

  12. Sensitivity and specificity of CT- and MRI-scanning in evaluation of occult fracture of the proximal femur.

    PubMed

    Haubro, M; Stougaard, C; Torfing, T; Overgaard, S

    2015-08-01

    To estimate sensitivity and specificity of CT and MRI examinations in patients with fractures of the proximal femur. To determine the interobserver agreement of the modalities among a senior consulting radiologist, a resident in radiology and a resident in orthopaedics surgery. 67 patients (27 males, 40 females, mean age 80.5) seen in the emergency room with hip pain after fall, inability to stand and a primary X-ray without fracture were evaluated with both CT and MRI. The images were analysed by a senior consulting musculoskeletal radiologist, a resident in radiology and a resident in orthopaedic surgery. Sensitivity and specificity were estimated with MRI as the golden standard. Kappa value was used to assess level of agreement in both MRI and CT finding. 15 fractures of the proximal femur were found (7 intertrochanteric-, 3 femoral neck and 5 fractures of the greater trochanter). Two fractures were not identified by CT and four changed fracture location. Among those, three patients underwent surgery. Sensitivity of CT was 0.87; 95% CI [0.60; 0.98]. Kappa for interobserver agreement for CT were 0.46; 95% CI [0.23; 0.76] and 0.67; 95% CI [0.42; 0.90]. For MRI 0.67; 95% CI [0.43; 0.91] and 0.69; 95% CI [0.45; 0.92]. MRI was observed to have a higher diagnostic accuracy than CT in detecting occult fractures of the hip. Interobserver analysis showed high kappa values corresponding substantial agreement in both CT and MRI. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. [Diagnostic imaging and acute abdominal pain].

    PubMed

    Liljekvist, Mads Svane; Pommergaard, Hans-Christian; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-19

    Acute abdominal pain is a common clinical condition. Clinical signs and symptoms can be difficult to interpret, and diagnostic imaging may help to identify intra-abdominal disease. Conventional X-ray, ultrasound (US) and computed tomography (CT) of the abdomen vary in usability between common surgical causes of acute abdominal pain. Overall, conventional X-ray cannot confidently diagnose or rule out disease. US and CT are equally trustworthy for most diseases. US with subsequent CT may enhance diagnostic precision. Magnetic resonance seems promising for future use in acute abdominal imaging.

  14. Comparative effectiveness of 18F-FDG PET-CT and contrast-enhanced CT in the diagnosis of suspected large-vessel vasculitis.

    PubMed

    Vaidyanathan, Sriram; Chattopadhyay, Arpita; Mackie, Sarah L; Scarsbrook, Andrew

    2018-06-21

    Large-vessel vasculitis (LVV) is a serious illness with potentially life-threatening consequences. 18 F-FDG PET-CT has emerged as a valuable diagnostic tool in suspected LVV, combining the strengths of functional and structural imaging. This study aimed to compare the accuracy of FDG PET-CT and contrast-enhanced CT (CECT) in the evaluation of patients with LVV. A retrospective database review for LVV patients undergoing CECT and PET-CT between 2011 to 2016 yielded demographics, scan interval and vasculitis type. Qualitative and quantitative PET-CT analyses included aorta: liver FDG uptake, bespoke FDG uptake distribution scores and vascular maximum standardized uptake values (SUVmax). Quantitative CECT data were assessed wall thickness and mural/lumen ratio. ROC curves were constructed to evaluate comparative diagnostic accuracy and a correlational analysis was conducted between SUVmax and wall-thickness. 36 adults (17 LVV, 19 controls) with a mean age (range) 63 (38-89) years, of which 17 (47%) were males were included. Time interval between CT and PET was mean (standard deviation (SD)) 1.9 (1.2) months. Both SUVmax and wall-thickness demonstrated a significant difference between LVV and controls, with a mean difference (95%confidence interval (CI)) for SUVmax 1.6 (1.1, 2.0) and wall thickness 1.25 (0.68, 1.83) mm, respectively. These two parameters were significantly correlated (p < .0001, R = 0.62). The area under the curve (AUC) (95% CI) for SUVmax was 0.95 (0.88-1.00), and for mural thickening was 0.83 (0.66-0.99). FDG PET-CT demonstrated excellent accuracy whilst CECT mural thickening showed good accuracy in the diagnosis of LVV. Both parameters showed a highly significant correlation. In hospitals without access to FDG PET-CT or in patients unsuitable for PET-CT (e.g., uncontrolled diabetes) CECT offers a viable alternative for the assessment LVV. Advances in knowledge: FDG PET-CT is a highly accurate test for the diagnosis of LVV. Aorta:liver SUVmax ratio is the most specific parameter for LVV. In hospitals without PET-CT or in unsuitable patients e.g. diabetics, CECT is a viable alternative.

  15. [Usefulness of ¹⁸F-fluoro-2-deoxyglucose positron emission tomography in evaluation of gastric cancer stage].

    PubMed

    Yoon, Na Ri; Park, Jae Myung; Jung, Hee Sun; Cho, Yu Kyung; Lee, In Seok; Choi, Myung Gyu; Chung, In Sik; Song, Kyo Young; Park, Cho Hyun

    2012-05-01

    The usefulness of ¹⁸F-fluoro-2-deoxyglucose (FDG)-PET in detecting primary cancer, lymph node metastasis, and distant metastasis were studied in the gastric cancer patients. The subjects were 392 gastric cancer patients who received FDG-PET and an abdominal CT test prior to surgery. The results of FDG-PET and CT were compared with the surgical and pathologic results. The primary site detection rate of FDG-PET was 74.4%, 50.3% in early gastric cancer and 92.0% in advanced gastric cancer. Detection rate was higher when tumors were larger than 3.5 cm, had deeper depth of invasion, and at a later stage (p<0.05, respectively). In multivariate analysis, tumor size, spread of tumor cells beyond the muscle layer (≥T2), and lymph node metastasis were statistically significant factors in primary site detection rate. The sensitivity, specificity, and positive predictive value of FDG-PET to lymph node metastasis were 59.6%, 88.8%, and 81.1% respectively, sensitivity being lower compared to CT while specificity and positive predictive value were higher. Sensitivity, specificity, and positive predictive value to distant metastasis were, respectively, 66.7%, 99.2%, and 88.0%, similar to CT. In 21 of the 392 patients (5.4%), synchronous double primary cancers were detected. In gastric cancer, usefullness of FDG-PET is limited to the advanced stage. Diagnostic value of this test was not superior to CT. However, FDG-PET may be useful in detecting synchronous double primary cancers.

  16. Dual tracer functional imaging of gastroenteropancreatic neuroendocrine tumors using 68Ga-DOTA-NOC PET-CT and 18F-FDG PET-CT: competitive or complimentary?

    PubMed

    Naswa, Niraj; Sharma, Punit; Gupta, Santosh Kumar; Karunanithi, Sellam; Reddy, Rama Mohan; Patnecha, Manish; Lata, Sneh; Kumar, Rakesh; Malhotra, Arun; Bal, Chandrasekhar

    2014-01-01

    This study aimed to compare the diagnostic performance of Ga-DOTANOC PET/CT with F-FDG PET/CT in the patients with gastroenteropancreatic neuroendocrine tumors (GEP-NETs). Data of 51 patients with definite histological diagnosis of GEP-NET who underwent both Ga-DOTA-NOC PET-CT and F-FDG PET-CT within a span of 15 days were selected for this retrospective analysis. Sensitivity, specificity, and predictive values were calculated for Ga-DOTA-NOC PET-CT and F-FDG PET-CT, and results were compared both on patientwise and regionwise analysis. Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT on patientwise analysis (P < 0.0001). On regionwise analysis, Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT only for lymph node metastases (P < 0.003). Although Ga-DOTA-NOC PET-CT detected more liver and skeletal lesions compared with F-FDG PET-CT, the difference was not statistically significant. In addition, the results of combined imaging helped in selecting candidates who would undergo the appropriate mode of treatment, whether octreotide therapy or conventional chemotherapy Ga-DOTA-NOC PET-CT seems to be superior to F-FDG PET-CT for imaging GEP-NETs. However, their role seems to be complementary because combination of Ga-DOTA-NOC PET-CT and F-FDG PET-CT in such patients helps demonstrate the total disease burden and segregate them to proper therapeutic groups.

  17. Assessment of Bowel Wall Enhancement for the Diagnosis of Intestinal Ischemia in Patients with Small Bowel Obstruction: Value of Adding Unenhanced CT to Contrast-enhanced CT.

    PubMed

    Chuong, Anh Minh; Corno, Lucie; Beaussier, Hélène; Boulay-Coletta, Isabelle; Millet, Ingrid; Hodel, Jérôme; Taourel, Patrice; Chatellier, Gilles; Zins, Marc

    2016-07-01

    Purpose To determine whether adding unenhanced computed tomography (CT) to contrast material-enhanced CT improves the diagnostic performance of decreased bowel wall enhancement as a sign of ischemia complicating mechanical small bowel obstruction (SBO). Materials and Methods This retrospective study was approved by the institutional review board, which waived the requirement for informed consent. Two gastrointestinal radiologists independently performed retrospective assessments of 164 unenhanced and contrast-enhanced CT studies from 158 consecutive patients (mean age, 71.2 years) with mechanical SBO. The reference standard was the intraoperative and/or histologic diagnosis (in 80 cases) or results from clinical follow-up in patients who did not undergo surgery (84 cases). Decreased bowel wall enhancement was evaluated with contrast-enhanced images then and both unenhanced and contrast-enhanced images 1 month later. Diagnostic performance of decreased bowel wall enhancement and confidence in the diagnosis were compared between the two readings by using McNemar and Wilcoxon signed rank tests. Interobserver agreement was assessed by using κ statistics and compared with bootstrapping. Results Ischemia was diagnosed in 41 of 164 (25%) episodes of SBO. For both observers, adding unenhanced images improved decreased bowel wall enhancement sensitivity (observer 1: 46.3% [19 of 41] vs 65.8% [27 of 41], P = .02; observer 2: 56.1% [23 of 41] vs 63.4% [26 of 41], P = .45), Youden index (from 0.41 to 0.58 for observer 1 and from 0.42 to 0.61 for observer 2), and confidence score (P < .001 for both). Specificity significantly increased for observer 2 (84.5% [104 of 123] vs 94.3% [116 of 123], P = .002), and interobserver agreement significantly increased, from moderate (κ = 0.48) to excellent (κ = 0.89; P < .0001). Conclusion Adding unenhanced CT to contrast-enhanced CT improved the sensitivity, diagnostic confidence, and interobserver agreement of the diagnosis of ischemia, a complication of mechanical SBO, on the basis of decreased bowel wall enhancement. (©) RSNA, 2016.

  18. [Spiral CT angiography in practice].

    PubMed

    Pavcec, Zlatko; Zokalj, Ivan; Rumboldt, Zoran; Pal, Andrej; Saghir, Hussein; Ozretić, David; Latin, Branko; Perhoć, Zeljka; Marotti, Miljenko

    2005-01-01

    Incidence of vascular diseases and development of new radiologic techniques in the last three decades has given strong impuls for introduction of non-invasive vascular diagnostic methods. Thanks to the introduction of Doppler ultrasound, new types of computed tomography (CT) and magnetic resonance (MR) scanners, non-invasive vascular diagnostic methods are replacing conventional invasive (catheter) angiographic methods. Computed tomographic angiography (CTA) is a noninvasive vascular diagnostic method based on continuous scanning with CT scanner during intravenous application of contrast material. Performing of CTA is possible after introduction of spiral CT technique whose characteristics are short imaging time and volumetric data acquisition. The main goal of this article, based on our experiences, is to review the role of CTA, performed on single-slice CT scanner, in managment of patients with vascular pathology.

  19. The diagnosis of acute appendicitis in a pediatric population: to CT or not to CT.

    PubMed

    Stephen, Antonia E; Segev, Dorry L; Ryan, Daniel P; Mullins, Mark E; Kim, Samuel H; Schnitzer, Jay J; Doody, Daniel P

    2003-03-01

    The aim of this study was to determine if focused appendiceal computed tomography with colon contrast (FACT-CC) increases the accuracy of the preoperative diagnosis of acute appendicitis in children. A 5-year retrospective review was conducted of a university hospital database of 283 patients (age 0.8 to 19.3 years; mean, 11.3 years) treated with appendectomy for presumed acute appendicitis. Of the 283 patients in whom appendectomies were performed, 268 were confirmed by pathologic analysis of the specimen to have acute appendicitis for a diagnostic accuracy in our institution of 94.7%. Ninety-six patients (34%) underwent FACT-CC scans as part of their preoperative evaluation. The sensitivity of the computed tomography (CT) scan was 94.6%, and the positive predictive value was 95.6%. In girls older than 10 years, CT imaging was not significantly more accurate in predicting appendicitis than examination alone (93.9% v. 87.5%; P =.46). Preoperative FACT-CC did not increase the accuracy in diagnosing appendicitis when compared with patients diagnosed by history, physical examination and laboratory studies. If there was a strong suspicion of appendicitis, a negative CT scan did not exclude the diagnosis of appendicitis. However, focused appendiceal CT scan is a sensitive test with a high positive predictive value and may be useful in a patient with an atypical history or examination. Copyright 2003, Elsevier Science (USA). All rights reserved.

  20. [Diagnosis and differential diagnosis for solitary fibrous tumor in the abdomen and pelvis by CT].

    PubMed

    Liu, Huaping; Li, Wenzheng; Yi, Xiaoping; Pei, Yigang; Liu, Hui; Zhao, Wei; Liu, Wenguang; Hou, Jiale; Ghimire, Obin

    2017-04-28

    To study the CT features for solitary fibrous tumor (SFT) in the abdomen and pelvis and to improve the diagnostic accuracy.
 Methods: Fourteen patients with SFT were collected in our hospital from January, 2011 to December, 2015. Characteristic of images were analyzed and compared for 10 SFT, which located outside the abdominal organs with extragastrointestinal stromal tumors (EGIST), leiomyosarcoma, and schwannoma.
 Results: Necrosis and cystic formation were frequently present in SFT in the abdomen and pelvis. CE-CT showed serpentine vessels along the periphery, while pattern of enhancement was map-like inhomogeneous progressive. Comparing with the EGIST or schwannoma, the difference of CT value in non-contrast and the arterial phase were statistically significant (P<0.05). The numbers of peritumoral circuity vessel were significantly different between SFT and EGIST (χ²=18.27, P<0.008) or between SFT and schwannoma (χ²=19.25, P<0.008). Comparing with the leiomyosarcoma or schwannoma, SFT located outside the abdominal organs. We found that tumor necrosis rate was significantly different between SFT and leiomyoscarcoma (χ²=8.00, P<0.008).
 Conclusion: SFT in the abdomen and pelvis show certain CT characteristics. The CT value in non-contrast and at the arterial phase, tumor necrosis rate, and serpentine vessels along the periphery were pivotal in differentiating SFT from leiomyosarcoma, EGIST and schwannoma.

  1. Contrast-enhanced multidetector computerized tomography for odontogenic cysts and cystic-appearing tumors of the jaws: is it useful?

    PubMed

    Kakimoto, Naoya; Chindasombatjaroen, Jira; Tomita, Seiki; Shimamoto, Hiroaki; Uchiyama, Yuka; Hasegawa, Yoko; Kishino, Mitsunobu; Murakami, Shumei; Furukawa, Souhei

    2013-01-01

    The purpose of this study was to investigate the usefulness of computerized tomography (CT), particularly contrast-enhanced CT, in differentiation of jaw cysts and cystic-appearing tumors. We retrospectively analyzed contrast-enhanced CT images of 90 patients with odontogenic jaw cysts or cystic-appearing tumors. The lesion size and CT values were measured and the short axis to long axis (S/L) ratio, contrast enhancement (CE) ratio, and standard deviation ratio were calculated. The lesion size and the S/L ratio of keratocystic odontogenic tumors were significantly different from those of radicular cysts and follicular cysts. There were no significant differences in the CE ratio among the lesions. Multidetector CT provided diagnostic information about the size of odontogenic cysts and cystic-appearing tumors of the jaws that was related to the lesion type, but showed no relation between CE ratio and the type of these lesions. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Diagnostic performance and useful findings of ultrasound re-evaluation for patients with equivocal CT features of acute appendicitis.

    PubMed

    Kim, Mi Sung; Kwon, Heon-Ju; Kang, Kyung A; Do, In-Gu; Park, Hee-Jin; Kim, Eun Young; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Young Hwan

    2018-02-01

    To evaluate the diagnostic performance of ultrasound and to determine which ultrasound findings are useful to differentiate appendicitis from non-appendicitis in patients who underwent ultrasound re-evaluation owing to equivocal CT features of acute appendicitis. 62 patients who underwent CT examinations for suspected appendicitis followed by ultrasound re-evaluation owing to equivocal CT findings were included. Equivocal CT findings were considered based on the presence of only one or two findings among the CT criteria, and ultrasound re-evaluation was done based on a predefined structured report form. The diagnostic performance of ultrasound and independent variables to discriminate appendicitis from non-appendicitis were assessed. There were 27 patients in the appendicitis group. The overall diagnostic performance of ultrasound re-evaluation was sensitivity of 96.3%, specificity of 91.2% and accuracy of 91.9%. In terms of the performance of individual ultrasound findings, probe-induced tenderness showed the highest accuracy (86.7%) with sensitivity of 74% and specificity of 97%, followed by non-compressibility (accuracy 71.7%, sensitivity 85.2% and specificity 60.6%). The independent ultrasound findings for discriminating appendicitis were non-compressibility (p = 0.002) and increased flow on the appendiceal wall (p = 0.001). Ultrasound re-evaluation can be used to improve diagnostic accuracy in cases with equivocal CT features for diagnosing appendicitis. The presence of non-compressibility and increased vascular flow on the appendix wall are useful ultrasound findings to discriminate appendicitis from non-appendicitis. Advances in knowledge: Ultrasound re-evaluation is useful to discriminate appendicitis from non-appendicitis when CT features are inconclusive.

  3. Comparison between esophagography and chest computed tomography for evaluation of leaks after esophagectomy and gastric pull-through.

    PubMed

    Lantos, Joshua E; Levine, Marc S; Rubesin, Stephen E; Lau, Charles T; Torigian, Drew A

    2013-03-01

    To assess the diagnostic performance of esophagography and chest computed tomography (CT) for detecting leaks after esophagectomy and gastric pull-through. Our database revealed 29 patients who had undergone esophagography and chest CT after esophagectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative leaks were determined for esophagography and CT, separately and combined, on the basis of a retrospective image review. Patients were also stratified for esophagograms with water-soluble contrast alone versus water-soluble contrast and high-density barium and for CT with and without oral contrast. Our findings were retrospectively compared with those reported at initial image interpretation. Clinically relevant leaks were present in 14 (48%) of 29 patients after esophagectomy. Esophagography had a sensitivity of 79%, specificity of 73%, PPV of 73%, and NPV of 79% for detecting leaks, whereas CT had a sensitivity of 86%, specificity of 33%, PPV of 55%, and NPV of 71% and esophagography and CT combined had a sensitivity of 100%, specificity of 27%, PPV of 56%, and NPV of 100%. The sensitivity of esophagography increased with high-density barium, whereas the sensitivity of CT was the same with and without oral contrast agent. Finally, esophagography and CT were seen to have a higher sensitivity and lower specificity on retrospective review compared with the results reported at initial image interpretation. Esophagography had a slightly lower sensitivity and substantially higher specificity compared with CT for detecting leaks after esophagectomy, whereas esophagography and CT combined had a sensitivity of 100% for detecting leaks. Therefore, postoperative leaks can be excluded with confidence after esophagectomy when both tests are negative.

  4. Comparison of 18F-FDG PET/CT and PET/MRI in patients with multiple myeloma

    PubMed Central

    Sachpekidis, Christos; Hillengass, Jens; Goldschmidt, Hartmut; Mosebach, Jennifer; Pan, Leyun; Schlemmer, Heinz-Peter; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2015-01-01

    PET/MRI represents a promising hybrid imaging modality with several potential clinical applications. Although PET/MRI seems highly attractive in the diagnostic approach of multiple myeloma (MM), its role has not yet been evaluated. The aims of this prospective study are to evaluate the feasibility of 18F-FDG PET/MRI in detection of MM lesions, and to investigate the reproducibility of bone marrow lesions detection and quantitative data of 18F-FDG uptake between the functional (PET) component of PET/CT and PET/MRI in MM patients. The study includes 30 MM patients. All patients initially underwent 18F-FDG PET/CT (60 min p.i.), followed by PET/MRI (120 min p.i.). PET/CT and PET/MRI data were assessed and compared based on qualitative (lesion detection) and quantitative (SUV) evaluation. The hybrid PET/MRI system provided good image quality in all cases without artefacts. PET/MRI identified 65 of the 69 lesions, which were detectable with PET/CT (94.2%). Quantitative PET evaluations showed the following mean values in MM lesions: SUVaverage=5.5 and SUVmax=7.9 for PET/CT; SUVaverage=3.9 and SUVmax=5.8 for PET/MRI. Both SUVaverage and SUVmax were significantly higher on PET/CT than on PET/MRI. Spearman correlation analysis demonstrated a strong correlation between both lesional SUVaverage (r=0.744) and lesional SUVmax (r=0.855) values derived from PET/CT and PET/MRI. Regarding detection of myeloma skeletal lesions, PET/MRI exhibited equivalent performance to PET/CT. In terms of tracer uptake quantitation, a significant correlation between the two techniques was demonstrated, despite the statistically significant differences in lesional SUVs between PET/CT and PET/MRI. PMID:26550538

  5. Feasibility study of basic characterization of MAGAT polymer gel using CBCT attached in linear accelerator: Preliminary study

    NASA Astrophysics Data System (ADS)

    Sathiyaraj, P.; Samuel, E. James jebaseelan

    2018-01-01

    The aim of this study is to evaluate the methacrylic acid, gelatin and tetrakis (hydroxymethyl) phosphonium chloride gel (MAGAT) by cone beam computed tomography (CBCT) attached with modern linear accelerator. To compare the results of standard diagnostic computed tomography (CT) with CBCT, different parameters such as linearity, sensitivity and temporal stability were checked. MAGAT gel showed good linearity for both diagnostic CT and CBCT measurements. Sensitivity and temporal stability were also comparable with diagnostic CT measurements. In both the modalities, the sensitivity of the MAGAT increased to 4 days and decreased till the 10th day of post irradiation. Since all measurements (linearity, sensitivity and temporal stability) from diagnostic CT and CBCT were comparable, CBCT could be a potential tool for dose analysis study for polymer gel dosimeter.

  6. Computed tomography for occult fractures of the proximal femur, pelvis, and sacrum in clinical practice: single institution, dual-site experience.

    PubMed

    Mandell, Jacob C; Weaver, Michael J; Khurana, Bharti

    2018-06-01

    The purpose of this study was to evaluate the diagnostic performance of CT for assessment of occult fractures of the proximal femur, pelvis, and sacrum. A retrospective review was performed on patients who received a CT of the hip or pelvis for suspected occult fracture after negative or equivocal radiographs performed within 24 h. The official radiology report was utilized for the determination of CT findings and calculation of sensitivity and specificity. Surgical reports, MRI reports, and clinical follow-up were used as the standard of reference. Sensitivity and specificity were calculated with 95% confidence intervals. Seventy-four patients received CT of the hip or pelvis for clinical concern for occult fracture after negative or equivocal radiographs. By the reference standard, a total of 40 fractures were present in 25/74 (33.8%) patients, including 35 conservatively treated fractures of the greater trochanter, pelvis, and sacrum, and 5 operatively treated proximal femoral fractures. A total of 14/74 (18.9%) of patients had an MRI within 1 day of CT. MRI identified an operatively treated femoral neck fracture not seen on CT and an operatively treated intertrochanteric fracture, which CT described as a greater trochanteric fracture. There were two false negative conservatively treated pelvic fractures not seen on CT but diagnosed on MRI. On a per-patient basis, CT had an overall sensitivity of 88% (22/25; 95% confidence intervals 69-97%), specificity of 98% (48/49; 95% confidence intervals 89-100%), and negative predictive value of 94%. For the five operative proximal femoral fractures, the sensitivity of CT was 60% (3/5; 95% confidence intervals 15-95%), specificity was 99% (68/69; 95% confidence intervals 92-100%), and negative predictive value was 97%. In the clinical setting of suspected occult fracture, the sensitivity of clinical CT reports for detection of any type of fracture of the proximal femur, pelvis, or sacrum was 88%. For the small number of operatively treated proximal femoral fractures seen in the study, sensitivity of CT was 60% (3/5) and negative predictive value was 97%, although the relatively few patients needing fixation precludes statistical analysis.

  7. Diagnostic performance of 68Gallium-PSMA-11 PET/CT to detect significant prostate cancer and comparison with 18FEC PET/CT.

    PubMed

    Hoffmann, Manuela A; Miederer, Matthias; Wieler, Helmut J; Ruf, Christian; Jakobs, Frank M; Schreckenberger, Mathias

    2017-12-19

    Radiolabeled prostate-specific membrane antigen (PSMA) has proven to be a highly accurate method to detect recurrence and metastases of prostate cancer, but only sparse data is available about its performance in the diagnosis of clinically significant primary prostate cancer. We compared 68 Ga-PSMA-11 PET/CT in 25 patients with 18 FEC PET/CT in 40 patients with suspected prostate carcinoma based on an increased PSA level.The PET/CT results were compared with the histopathologic Gleason Score (GS) of biopsies. The 68 Ga-PSMA-11 PET/CT revealed highly suspect prostatic lesions (maximum standardized uptake value/SUV max >2.5) in 21/25 patients (84%), associated with GS≥6 (low-grade/high-grade carcinoma). Two histopathologic non-malignancy-relevant cases (GS<6) had PSMA-SUV max ≤2.5; all histopathologic high-grade cases (GS≥7b) showed PSMA-SUV max >12.0 which further increased with rising GS. There were 2 false positives and no false negative findings for high-grade prostate cancer using a cut off-level for SUV max of 2.5.In contrast, the 18 FEC PET/CT showed suspected malignant lesions in 38/40 patients (95%), which included 3 lesions with GS<6. The mean SUV max values did not differ with different GS. There were 11 false positives and 1 false negative for detection of high-grade prostate cancer (cut off 2.5).By means of ROC analysis a SUV max of 5.4 was found to be an optimal cut off-level to distinguish between low- and high-grade carcinoma in 68 Ga-PSMA-11 PET/CT (AUC=0.9692; 95% CI 0.9086;1.0000;SD(AUC)=0.0309)). Choosing a cut off-level of SUV max 5.4, 68 Ga-PSMA-11 PET/CT was able to distinguish between GS ≤7a/≥7b with a sensitivity of 84%, a specificity of 100%, a negative predictive value (NPV) of 67%, and an efficiency of 88% ( p <0.001).The ROC analysis revealed a SUV max 6.5 as an optimal cut off-level to distinguish between low- and high-grade carcinoma in 18 FEC PET/CT (AUC=0.7470; 95% CI 0.5919;0.9020;SD(AUC)=0.0791) with a sensitivity of 61% and a specificity of 92%; but the efficiency was only 70% and the NPV 50% ( p =0.01). 68 Ga-PSMA-11 PET/CT guided biopsy of the prostate increases diagnostic precision and is likely to help to reduce overtreatment of low-grade malignant disease as well as detect the foci of the highest Gleason pattern. Both methods ( 68 Ga-PSMA-11, 18 FEC) were suitable to detect primary prostate cancer, but the excellent image quality, the higher specificity and the good correlation of positive scans with GS are advantages of 68 Ga-PSMA-11.

  8. [Has high-definition spiral computed tomography changed the management of patients with acute pulmonary embolism?].

    PubMed

    Pesavento, Raffaele; de Conti, Giorgio; Minotto, Isabella; Prandoni, Paolo

    2008-12-01

    Pulmonary embolism (PE) is a common condition carrying a significant degree of mortality if not diagnosed early. The diagnosis of PE is challenging, because of the non-specific nature of its clinical features. For many years the diagnostic strategies for PE have mainly involved ventilation/perfusion lung scan as the chief diagnostic procedure, often associated with a few clinical models of pre-test probability and the D-dimer test. These modalities of diagnosing PE, though quite satisfactory in various clinical settings, show several limitations, the most important one being the high rate of non-diagnostic procedures. The introduction of computed tomography (CT) has changed the diagnostic strategies and has become the main diagnostic procedure for diagnosing PE. CT is undergoing a rapid technological upgrade, which will open in the near future new frontiers in the diagnosis of PE. Nonetheless, CT carries a number of limitations, which should be carefully identified. This article reviews the evidences on both the traditional and newer diagnostic strategies for PE, outlines their strengths and weaknesses and describes future applications of CT for diagnosing PE.

  9. Hybrid SPECT-CT and PET-CT imaging of differentiated thyroid carcinoma.

    PubMed

    Wong, K K; Zarzhevsky, N; Cahill, J M; Frey, K A; Avram, A M

    2009-10-01

    Hybrid imaging modalities such as radioiodine single photon emission CT with integrated CT ((131)I SPECT-CT) and 2-(fluorine-18)-fluoro-2-deoxy-D-glucose positron emission tomography with integrated CT (FDG PET-CT) allow the rapid and efficient fusion of functional and anatomic images, and provide diagnostic information that may influence management decisions in patients with differentiated thyroid carcinoma (DTC). Diagnostic localisation and therapy of these tumours are dependent upon their capacity to concentrate radioiodine ((131)I) via uptake through the sodium-iodide symporter and retention within the tumour. The prognosis for most patients with DTC is favourable, although controversy exists regarding the role of post-operative (131)I therapy in patients at low-risk for disease. Accurate identification of functional thyroid tissue (benign or malignant) using diagnostic (131)I planar scintigraphy complemented by SPECT-CT imaging enables the completion of post-operative staging and patient risk stratification prior to (131)I therapy administration. In patients with non-iodine-avid tumours (negative (131)I scan but elevated thyroglobulin indicative of persistent or recurrent disease), FDG PET-CT is used to identify tumours with enhanced glucose metabolism and to localise the source of thyroglobulin production. The CT component of this hybrid technology provides anatomic localisation of activity and allows CT-based attenuation correction of PET images. Images from 15 patients illustrate the applications of (131)I SPECT-CT and FDG PET-CT.

  10. Exercise Electrocardiogram Neither Predicts Nor Excludes Coronary Artery Disease in Women with Low to Intermediate Risk.

    PubMed

    Knol, Remco J J; Kan, Huub; Wondergem, Maurits; Cornel, Jan H; Umans, Victor A W M; van der Ploeg, Tjeerd; van der Zant, Friso M

    2018-04-01

    The value of exercise electrocardiogram (ExECG) in symptomatic female patients with low to intermediate risk for significant coronary artery disease (CAD) has been under debate for many years, and nondiagnostic or even erroneous test results are frequently encountered. Cardiac-CT may be more appropriate to exclude CAD in women. This study compares the results of ExECGs with those of cardiac-CTs, performed within a time frame of 1 month in an all-comers female chest pain population. Five hundred fifty-one consecutive female patients from a patient registry were included. ExECGs were negative in 324 (59%), positive in 14 (3%), and nondiagnostic in 213 (39%) patients. CAD was revealed by cardiac-CT in 57% of the women with negative ExECG. No signs of CAD were present on cardiac-CT in 64% of the women with a positive ExECG. Cardiac-CT showed presence of CAD in 268/551 (49%) patients, of whom 56/268 (21%) was diagnosed with ≥50% stenosis. The ExECG of the latter group was negative in 26 (46%), inconclusive in 29 (52%), and positive in 1 (2%). Considering ≥50% stenosis at cardiac-CT as the reference, sensitivity, specificity, PPV, and NPV of ExECG for the present population were 3.7%, 95.7%, 7.1%, and 91.7%, respectively. Similar diagnostic performance was calculated when considering ≥70% stenosis at cardiac-CT as the reference. ExECG failed to detect CAD in more than half of this cohort and in almost half of women with >50% stenosis at cardiac-CT. Importantly, no CAD was detected by cardiac-CT in 64% of women with a positive ExECG. ExECG is therefore questionable as a diagnostic strategy in women with low-to-intermediate risk of CAD, although prospective studies are warranted to determine whether replacing ExECG by cardiac-CT provides better prognoses.

  11. CT-based radiomics signature for differentiating Borrmann type IV gastric cancer from primary gastric lymphoma.

    PubMed

    Ma, Zelan; Fang, Mengjie; Huang, Yanqi; He, Lan; Chen, Xin; Liang, Cuishan; Huang, Xiaomei; Cheng, Zixuan; Dong, Di; Liang, Changhong; Xie, Jiajun; Tian, Jie; Liu, Zaiyi

    2017-06-01

    To evaluate the value of CT-based radiomics signature for differentiating Borrmann type IV gastric cancer (GC) from primary gastric lymphoma (PGL). 40 patients with Borrmann type IV GC and 30 patients with PGL were retrospectively recruited. 485 radiomics features were extracted and selected from the portal venous CT images to build a radiomics signature. Subjective CT findings, including gastric wall peristalsis, perigastric fat infiltration, lymphadenopathy below the renal hila and enhancement pattern, were assessed to construct a subjective findings model. The radiomics signature, subjective CT findings, age and gender were integrated into a combined model by multivariate analysis. The diagnostic performance of these three models was assessed with receiver operating characteristics curves (ROC) and were compared using DeLong test. The subjective findings model, the radiomics signature and the combined model showed a diagnostic accuracy of 81.43% (AUC [area under the curve], 0.806; 95% CI [confidence interval]: 0.696-0.917; sensitivity, 63.33%; specificity, 95.00%), 84.29% (AUC, 0.886 [95% CI: 0.809-0.963]; sensitivity, 86.67%; specificity, 82.50%), 87.14% (AUC, 0.903 [95%CI: 0.831-0.975]; sensitivity, 70.00%; specificity, 100%), respectively. There were no significant differences in AUC among these three models (P=0.051-0.422). Radiomics analysis has the potential to accurately differentiate Borrmann type IV GC from PGL. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Diagnostic performance of a biomarker panel as a negative predictor for acute appendicitis in adult ED patients with abdominal pain.

    PubMed

    Huckins, David S; Copeland, Karen; Self, Wesley; Vance, Cheryl; Hendry, Phyllis; Borg, Keith; Gogain, Joseph

    2017-03-01

    Evaluate the diagnostic accuracy of the APPY1TM biomarker panel, previously described for use in pediatric patients, for identifying adult ED patients with abdominal pain who are at low risk of acute appendicitis. This study prospectively enrolled subjects >18years of age presenting to seven U.S. emergency departments with <72hours of abdominal pain suggesting possible acute appendicitis. The APPY1 panel was performed on blood samples drawn from each patient at the time of initial evaluation and results were correlated with the final diagnosis either positive or negative for acute appendicitis. 431 patients were enrolled with 422 completing all aspects of the study. The APPY1 biomarker panel exhibited a sensitivity of 97.5% (95% CI, 91.3-99.3%), a negative predictive value of 98.4% (95% CI, 94.4-99.6%), a negative likelihood ratio of 0.07 (95% CI, 0.02-0.27), with a specificity of 36.5% (95% CI, 31.6-41.8%) for acute appendicitis. The panel correctly identified 125 of 342 (36.6%) patients who did not have appendicitis with 2 (2.5%) false negatives. The CT utilization rate in this population was 72.7% (307/422). Of 307 CT scans, 232 were done for patients who did not have appendicitis and 79 (34%) of these patients were correctly identified as negative with "low risk" biomarker panel results, representing 26% (79/307) of all CT scans performed. This biomarker panel exhibited high sensitivity and negative predictive value for acute appendicitis in this prospective adult cohort, thereby potentially reducing the dependence on CT for the evaluation of possible acute appendicitis. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Diagnosis demystified: CT as diagnostic tool in endodontics

    PubMed Central

    Shruthi, Nagaraja; Sreenivasa Murthy, B V; Sundaresh, K J; Mallikarjuna, Rachappa

    2013-01-01

    Diagnosis in endodontics is usually based on clinical and radiographical presentations, which are only empirical methods. The role of healing profession is to apply knowledge and skills towards maintaining and restoring the patient's health. Recent advances in imaging technologies have added to correct interpretation and diagnosis. CT is proving to be an effective tool in solving endodontic mysteries through its three-dimensional visualisation. CT imaging offers many diagnostic advantages to produce reconstructed images in selected projection and low-contrast resolution far superior to that of all other X-ray imaging modalities. This case report is an endeavour towards effective treatment planning of cases with root fracture, root resorption using spiral CT as an adjuvant diagnostic tool. PMID:23814212

  14. Diagnostic accuracy of 18F-FDG-PET and PET/CT in the differential diagnosis between malignant and benign pleural lesions: a systematic review and meta-analysis.

    PubMed

    Treglia, Giorgio; Sadeghi, Ramin; Annunziata, Salvatore; Lococo, Filippo; Cafarotti, Stefano; Bertagna, Francesco; Prior, John O; Ceriani, Luca; Giovanella, Luca

    2014-01-01

    To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  15. Patient doses from CT examinations in Turkey.

    PubMed

    Ataç, Gökçe Kaan; Parmaksız, Aydın; İnal, Tolga; Bulur, Emine; Bulgurlu, Figen; Öncü, Tolga; Gündoğdu, Sadi

    2015-01-01

    We aimed to establish the first diagnostic reference levels (DRLs) for computed tomography (CT) examinations in adult and pediatric patients in Turkey and compare these with international DRLs. CT performance information and examination parameters (for head, chest, high-resolution CT of the chest [HRCT-chest], abdominal, and pelvic protocols) from 1607 hospitals were collected via a survey. Dose length products and effective doses for standard patient sizes were calculated from the reported volume CT dose index (CTDIvol). The median number of protocols reported from the 167 responding hospitals (10% response rate) was 102 across five different age groups. Third quartile CTDIvol values for adult pelvic and all pediatric body protocols were higher than the European Commission standards but were comparable to studies conducted in other countries. The radiation dose indicators for adult patients were similar to those reported in the literature, except for those associated with head protocols. CT protocol optimization is necessary for adult head and pediatric chest, HRCT-chest, abdominal, and pelvic protocols. The findings from this study are recommended for use as national DRLs in Turkey.

  16. Diagnostic utility of attenuation measurement (Hounsfield units) in computed tomography stonogram in predicting the radio-opacity of urinary calculi in plain abdominal radiographs.

    PubMed

    Chua, Michael E; Gatchalian, Glenn T; Corsino, Michael Vincent; Reyes, Buenaventura B

    2012-10-01

    (1) To determine the best cut-off level of Hounsfield units (HU) in the CT stonogram that would predict the appearance of a urinary calculi in plain KUB X-ray; (2) to estimate the sensitivity and specificity of the best cut-off HU; and (3) to determine whether stone size and location affect the in vivo predictability. A prospective cross-sectional study of patients aged 18-85 diagnosed with urolithiases on CT stonogram with concurrent plain KUB radiograph was conducted. Appearance of stones was recorded, and significant difference between radiolucent and radio-opaque CT attenuation level was determined using ANOVA. Receiver operating characteristics (ROC) curve determined the best HU cut-off value. Stone size and location were used for factor variability analysis. A total of 184 cases were included in this study, and the average urolithiasis size on CT stonogram was 0.84 cm (0.3-4.9 cm). On KUB X-ray, 34.2 % of the urolithiases were radiolucent and 65.8 % were radio-opaque. Mean value of CT Hounsfield unit for radiolucent stones was 358.25 (±156), and that for radio-opaque stones was 816.51 (±274). ROC curve determined the best cut-off value of HU at 498.5, with the sensitivity of 89.3 % and specificity of 87.3 %. For >4 mm stones, the sensitivity was 91.3 % and the specificity was 81.8 %. On the other hand, for =<4 mm stones, the sensitivity was 60 % and the specificity was 89.5 %. Based on the constructed ROC curve, a threshold value of 498.5 HU in CT stonogram was established as cut-off in determining whether a calculus is radio-opaque or radiolucent. The determined overall sensitivity and specificity of the set cut-off HU value are optimal. Stone size but not location affects the sensitivity and specificity.

  17. Feasibility assessment of yttrium-90 liver radioembolization imaging using amplitude-based gated PET/CT

    PubMed Central

    Acuff, Shelley N.; Neveu, Melissa L.; Syed, Mumtaz; Kaman, Austin D.; Fu, Yitong

    2018-01-01

    Purpose The usage of PET/computed tomography (CT) to monitor hepatocellular carcinoma patients following yttrium-90 (90Y) radioembolization has increased. Respiratory motion causes liver movement, which can be corrected using gating techniques at the expense of added noise. This work examines the use of amplitude-based gating on 90Y-PET/CT and its potential impact on diagnostic integrity. Patients and methods Patients were imaged using PET/CT following 90Y radioembolization. A respiratory band was used to collect respiratory cycle data. Patient data were processed as both standard and motion-corrected images. Regions of interest were drawn and compared using three methods. Activity concentrations were calculated and converted into dose estimates using previously determined and published scaling factors. Diagnostic assessments were performed using a binary scale created from published 90Y-PET/CT image interpretation guidelines. Results Estimates of radiation dose were increased (P<0.05) when using amplitude-gating methods with 90Y PET/CT imaging. Motion-corrected images show increased noise, but the diagnostic determination of success, using the Kao criteria, did not change between static and motion-corrected data. Conclusion Amplitude-gated PET/CT following 90Y radioembolization is feasible and may improve 90Y dose estimates while maintaining diagnostic assessment integrity. PMID:29351124

  18. Comparison of machine learning methods for classifying mediastinal lymph node metastasis of non-small cell lung cancer from 18F-FDG PET/CT images.

    PubMed

    Wang, Hongkai; Zhou, Zongwei; Li, Yingci; Chen, Zhonghua; Lu, Peiou; Wang, Wenzhi; Liu, Wanyu; Yu, Lijuan

    2017-12-01

    This study aimed to compare one state-of-the-art deep learning method and four classical machine learning methods for classifying mediastinal lymph node metastasis of non-small cell lung cancer (NSCLC) from 18 F-FDG PET/CT images. Another objective was to compare the discriminative power of the recently popular PET/CT texture features with the widely used diagnostic features such as tumor size, CT value, SUV, image contrast, and intensity standard deviation. The four classical machine learning methods included random forests, support vector machines, adaptive boosting, and artificial neural network. The deep learning method was the convolutional neural networks (CNN). The five methods were evaluated using 1397 lymph nodes collected from PET/CT images of 168 patients, with corresponding pathology analysis results as gold standard. The comparison was conducted using 10 times 10-fold cross-validation based on the criterion of sensitivity, specificity, accuracy (ACC), and area under the ROC curve (AUC). For each classical method, different input features were compared to select the optimal feature set. Based on the optimal feature set, the classical methods were compared with CNN, as well as with human doctors from our institute. For the classical methods, the diagnostic features resulted in 81~85% ACC and 0.87~0.92 AUC, which were significantly higher than the results of texture features. CNN's sensitivity, specificity, ACC, and AUC were 84, 88, 86, and 0.91, respectively. There was no significant difference between the results of CNN and the best classical method. The sensitivity, specificity, and ACC of human doctors were 73, 90, and 82, respectively. All the five machine learning methods had higher sensitivities but lower specificities than human doctors. The present study shows that the performance of CNN is not significantly different from the best classical methods and human doctors for classifying mediastinal lymph node metastasis of NSCLC from PET/CT images. Because CNN does not need tumor segmentation or feature calculation, it is more convenient and more objective than the classical methods. However, CNN does not make use of the import diagnostic features, which have been proved more discriminative than the texture features for classifying small-sized lymph nodes. Therefore, incorporating the diagnostic features into CNN is a promising direction for future research.

  19. The Utility of FDG-PET/CT in Clinically Suspected Paraneoplastic Neurological Syndrome: A Literature Review and Retrospective Case Series.

    PubMed

    Maskery, Mark P; Hill, Jonathan; Cain, John R; Emsley, Hedley C A

    2017-01-01

    Paraneoplastic neurological syndrome (PNS) describes a spectrum of rare, heterogeneous neurological conditions associated with an underlying malignancy. Diagnosis of PNS is inherently difficult, with frequent misdiagnosis and delay. The literature suggests an underlying immune-mediated pathophysiology, and patients are usually tested for the presence of onconeural antibodies. With direct tumor therapy being the most effective method of stabilizing patients, there is a strong emphasis on detecting underlying tumors. The sensitivity of conventional CT imaging is often inadequate in such patients. While FDG-PET imaging has already been shown to be effective at detecting these tumors, FDG-PET/CT, combining both structural and functional imaging in a single study, is a more recent technique. To study the utility of FDG-PET/CT, we conducted a systematic literature review and a retrospective study. We identified 41 patients who underwent imaging for clinically suspected PNS at the regional PET-CT and neurosciences center based at the Royal Preston Hospital between 2007 and 2014 and compared the results to conventional investigations. Five patients had FDG-PET/CT tracer avidity suspicious of malignant disease, and four of these were subsequently diagnosed with cancer. Sensitivity and specificity were calculated to be 100 and 97.3%, respectively, with positive predictive value 80% and negative predictive value 100%. This compares to a sensitivity and specificity of 50 and 100%, respectively, for CT and 50 and 89%, respectively, for onconeural antibodies. These findings are in line with previous studies and support the diagnostic accuracy of FDG-PET/CT for the detection of underlying malignancy.

  20. Effects of bacterial contamination of media on the diagnosis of Tritrichomonas foetus by culture and real-time PCR.

    PubMed

    Clothier, Kristin A; Villanueva, Michelle; Torain, Andrea; Hult, Cynthia; Wallace, Rachel

    2015-03-15

    The venereal pathogen Tritrichomonas foetus causes early embryonic death and abortion in cattle. With no approved treatment, control involves detection of infected animals and their removal from the herd. Culture is the traditional diagnostic method; standard media are formulated to support protozoal growth while suppressing competing organisms which may prevent microscopic recognition of T. foetus. Real-time PCR increases diagnostic sensitivity and specificity over culture but requires intact T. foetus DNA for detection. The purposes of this study were 1) to evaluate the effects of resident preputial bacteria that are not suppressed by antimicrobials in a commercial culture medium (InPouch™) on T. foetus detection by culture and PCR, and 2) to determine the performance of a laboratory-prepared culture medium on T. foetus detection by culture and PCR in samples with and without this bacterial contamination. A known concentration of one of three different strains of T. foetus inoculated into InPouch™ (IP) or modified Diamonds-Plastridge media (DPM) were co-incubated with a smegma culture media (CONTAM) for 24h and examined microscopically for the presence of identifiable T. foetus. PCR was performed on IP samples to determine if CONTAM also affected T. foetus DNA detection. A PCR protocol was then validated in DPM that performed similarly to the established IP PCR method. IP and DPM with CONTAM were spiked with serial dilutions that mimic field infections of one of four T. foetus strains and evaluated by real-time PCR; cycles to threshold (Ct) values and "positive" classification were compared between media. T. foetus motility and morphology as well as media pH were severely altered in IP samples with CONTAM compared to those without as well as to DPM medium with and without CONTAM (P<0.0001). PCR testing demonstrated significantly greater Ct values were for T. foetus DNA (P<0.001) in IP contaminated with smegma bacteria compared to those without. When using T foetus concentrations that mimic field infections, IP samples with CONTAM had significantly higher Ct values (P<0.001) than DPM with CONTAM. Using the laboratory cut-off for "positive" on mean Ct values from these samples, significantly (P<0.01) more bulls would be identified using DPM than with IP if CONTAM was present. Results of this study indicate that bacteria which are not inhibited in media interfere with T. foetus identification by culture and PCR and adversely affect diagnostic sensitivity for this fastidious pathogen. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Feasibility Study of Radiation Dose Reduction in Adult Female Pelvic CT Scan with Low Tube-Voltage and Adaptive Statistical Iterative Reconstruction

    PubMed Central

    Wang, Xinlian; Chen, Jianghong; Hu, Zhihai; Zhao, Liqin

    2015-01-01

    Objective To evaluate image quality of female pelvic computed tomography (CT) scans reconstructed with the adaptive statistical iterative reconstruction (ASIR) technique combined with low tube-voltage and to explore the feasibility of its clinical application. Materials and Methods Ninety-four patients were divided into two groups. The study group used 100 kVp, and images were reconstructed with 30%, 50%, 70%, and 90% ASIR. The control group used 120 kVp, and images were reconstructed with 30% ASIR. The noise index was 15 for the study group and 11 for the control group. The CT values and noise levels of different tissues were measured. The contrast to noise ratio (CNR) was calculated. A subjective evaluation was carried out by two experienced radiologists. The CT dose index volume (CTDIvol) was recorded. Results A 44.7% reduction in CTDIvol was observed in the study group (8.18 ± 3.58 mGy) compared with that in the control group (14.78 ± 6.15 mGy). No significant differences were observed in the tissue noise levels and CNR values between the 70% ASIR group and the control group (p = 0.068-1.000). The subjective scores indicated that visibility of small structures, diagnostic confidence, and the overall image quality score in the 70% ASIR group was the best, and were similar to those in the control group (1.87 vs. 1.79, 1.26 vs. 1.28, and 4.53 vs. 4.57; p = 0.122-0.585). No significant difference in diagnostic accuracy was detected between the study group and the control group (42/47 vs. 43/47, p = 1.000). Conclusion Low tube-voltage combined with automatic tube current modulation and 70% ASIR allowed the low CT radiation dose to be reduced by 44.7% without losing image quality on female pelvic scan. PMID:26357499

  2. Quality Assurance Assessment of Diagnostic and Radiation Therapy–Simulation CT Image Registration for Head and Neck Radiation Therapy: Anatomic Region of Interest–based Comparison of Rigid and Deformable Algorithms

    PubMed Central

    Mohamed, Abdallah S. R.; Ruangskul, Manee-Naad; Awan, Musaddiq J.; Baron, Charles A.; Kalpathy-Cramer, Jayashree; Castillo, Richard; Castillo, Edward; Guerrero, Thomas M.; Kocak-Uzel, Esengul; Yang, Jinzhong; Court, Laurence E.; Kantor, Michael E.; Gunn, G. Brandon; Colen, Rivka R.; Frank, Steven J.; Garden, Adam S.; Rosenthal, David I.

    2015-01-01

    Purpose To develop a quality assurance (QA) workflow by using a robust, curated, manually segmented anatomic region-of-interest (ROI) library as a benchmark for quantitative assessment of different image registration techniques used for head and neck radiation therapy–simulation computed tomography (CT) with diagnostic CT coregistration. Materials and Methods Radiation therapy–simulation CT images and diagnostic CT images in 20 patients with head and neck squamous cell carcinoma treated with curative-intent intensity-modulated radiation therapy between August 2011 and May 2012 were retrospectively retrieved with institutional review board approval. Sixty-eight reference anatomic ROIs with gross tumor and nodal targets were then manually contoured on images from each examination. Diagnostic CT images were registered with simulation CT images rigidly and by using four deformable image registration (DIR) algorithms: atlas based, B-spline, demons, and optical flow. The resultant deformed ROIs were compared with manually contoured reference ROIs by using similarity coefficient metrics (ie, Dice similarity coefficient) and surface distance metrics (ie, 95% maximum Hausdorff distance). The nonparametric Steel test with control was used to compare different DIR algorithms with rigid image registration (RIR) by using the post hoc Wilcoxon signed-rank test for stratified metric comparison. Results A total of 2720 anatomic and 50 tumor and nodal ROIs were delineated. All DIR algorithms showed improved performance over RIR for anatomic and target ROI conformance, as shown for most comparison metrics (Steel test, P < .008 after Bonferroni correction). The performance of different algorithms varied substantially with stratification by specific anatomic structures or category and simulation CT section thickness. Conclusion Development of a formal ROI-based QA workflow for registration assessment demonstrated improved performance with DIR techniques over RIR. After QA, DIR implementation should be the standard for head and neck diagnostic CT and simulation CT allineation, especially for target delineation. © RSNA, 2014 Online supplemental material is available for this article. PMID:25380454

  3. Metal artifact reduction software used with abdominopelvic dual-energy CT of patients with metal hip prostheses: assessment of image quality and clinical feasibility.

    PubMed

    Han, Seung Chol; Chung, Yong Eun; Lee, Young Han; Park, Kwan Kyu; Kim, Myeong Jin; Kim, Ki Whang

    2014-10-01

    The objective of our study was to determine the feasibility of using Metal Artifact Reduction (MAR) software for abdominopelvic dual-energy CT in patients with metal hip prostheses. This retrospective study included 33 patients (male-female ratio, 19:14; mean age, 63.7 years) who received total hip replacements and 20 patients who did not have metal prostheses as the control group. All of the patients underwent dual-energy CT. The quality of the images reconstructed using the MAR algorithm and of those reconstructed using the standard reconstruction was evaluated in terms of the visibility of the bladder wall, pelvic sidewall, rectal shelf, and bone-prosthesis interface and the overall diagnostic image quality with a 4-point scale. The mean and SD attenuation values in Hounsfield units were measured in the bladder, pelvic sidewall, and rectal shelf. For validation of the MAR interpolation algorithm, pelvis phantoms with small bladder "lesions" and metal hip prostheses were made, and images of the phantoms both with and without MAR reconstruction were evaluated. Image quality was significantly better with MAR reconstruction than without at all sites except the rectal shelf, where the image quality either had not changed or had worsened after MAR reconstruction. The mean attenuation value was changed after MAR reconstruction to its original expected value at the pelvic sidewall (p < 0.001) and inside the bladder (p < 0.001). The SD attenuation value was significantly decreased after MAR reconstruction at the pelvic sidewall (p = 0.019) but did not show significant differences at the bladder (p = 0.173) or rectal shelf (p = 0.478). In the phantom study, all lesions obscured by metal artifacts on the standard reconstruction images were visualized after MAR reconstruction; however, new artifacts had developed in other parts of the MAR reconstruction images. The use of MAR software with dual-energy CT decreases metal artifacts and increases diagnostic confidence in the assessment of the pelvic cavity but also introduces new artifacts that can obscure pelvic structures.

  4. Yield of diagnostic procedures for invasive fungal infections in neutropenic febrile patients with chest computed tomography abnormalities.

    PubMed

    Ho, Dora Y; Lin, Margaret; Schaenman, Joanna; Rosso, Fernando; Leung, Ann N C; Coutre, Steven E; Sista, Ramachandra R; Montoya, Jose G

    2011-01-01

    Haematological patients with neutropenic fever are frequently evaluated with chest computed tomography (CT) to rule out invasive fungal infections (IFI). We retrospectively analysed data from 100 consecutive patients with neutropenic fever and abnormal chest CT from 1998 to 2005 to evaluate their chest CT findings and the yield of diagnostic approaches employed. For their initial CTs, 79% had nodular opacities, with 24.1% associated with the halo sign. Other common CT abnormalities included pleural effusions (48%), ground glass opacities (37%) and consolidation (31%). The CT findings led to a change in antifungal therapy in 54% of the patients. Fifty-six patients received diagnostic procedures, including 46 bronchoscopies, 25 lung biopsies and seven sinus biopsies, with a diagnostic yield for IFI of 12.8%, 35.0% and 83.3%, respectively. In conclusion, chest CT plays an important role in the evaluation of haematological patients with febrile neutropenia and often leads to a change in antimicrobial therapy. Pulmonary nodules are the most common radiological abnormality. Sinus or lung biopsies have a high-diagnostic yield for IFI as compared to bronchoscopy. Patients with IFI may not have sinus/chest symptoms, and thus, clinicians should have a low threshold for performing sinus/chest imaging, and if indicated and safe, a biopsy of the abnormal areas. © 2009 Blackwell Verlag GmbH.

  5. Results of the two incidence screenings in the National Lung Screening Trial.

    PubMed

    Aberle, Denise R; DeMello, Sarah; Berg, Christine D; Black, William C; Brewer, Brenda; Church, Timothy R; Clingan, Kathy L; Duan, Fenghai; Fagerstrom, Richard M; Gareen, Ilana F; Gatsonis, Constantine A; Gierada, David S; Jain, Amanda; Jones, Gordon C; Mahon, Irene; Marcus, Pamela M; Rathmell, Joshua M; Sicks, JoRean

    2013-09-05

    The National Lung Screening Trial was conducted to determine whether three annual screenings (rounds T0, T1, and T2) with low-dose helical computed tomography (CT), as compared with chest radiography, could reduce mortality from lung cancer. We present detailed findings from the first two incidence screenings (rounds T1 and T2). We evaluated the rate of adherence of the participants to the screening protocol, the results of screening and downstream diagnostic tests, features of the lung-cancer cases, and first-line treatments, and we estimated the performance characteristics of both screening methods. At the T1 and T2 rounds, positive screening results were observed in 27.9% and 16.8% of participants in the low-dose CT group and in 6.2% and 5.0% of participants in the radiography group, respectively. In the low-dose CT group, the sensitivity was 94.4%, the specificity was 72.6%, the positive predictive value was 2.4%, and the negative predictive value was 99.9% at T1; at T2, the positive predictive value increased to 5.2%. In the radiography group, the sensitivity was 59.6%, the specificity was 94.1%, the positive predictive value was 4.4%, and the negative predictive value was 99.8% at T1; both the sensitivity and the positive predictive value increased at T2. Among lung cancers of known stage, 87 (47.5%) were stage IA and 57 (31.1%) were stage III or IV in the low-dose CT group at T1; in the radiography group, 31 (23.5%) were stage IA and 78 (59.1%) were stage III or IV at T1. These differences in stage distribution between groups persisted at T2. Low-dose CT was more sensitive in detecting early-stage lung cancers, but its measured positive predictive value was lower than that of radiography. As compared with radiography, the two annual incidence screenings with low-dose CT resulted in a decrease in the number of advanced-stage cancers diagnosed and an increase in the number of early-stage lung cancers diagnosed. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.).

  6. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    PubMed

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  7. Fluorodeoxyglucose positron emission tomography for detection of tumor recurrence following radiofrequency ablation in retrospective cohort of stage I lung cancer.

    PubMed

    Wang, Yingbing; Lanuti, Michael; Bernheim, Adam; Shepard, Jo-Anne O; Sharma, Amita

    2018-05-03

    The goal of this study was to define patterns for tumor recurrence on PET following RFA, compare time to imaging recurrence by PET versus CT, evaluate whether pre-treatment tumor uptake predicts recurrence and propose an optimal post-RFA surveillance strategy. A retrospective cohort study was performed of biopsy confirmed primary stage I lung cancers treated with RFA. FDG PET and near contemporaneous diagnostic CT imaging pre-ablation, within 30 days post-ablation, and beyond 6 months were independently and retrospectively evaluated for features supportive of recurrence. Time to imaging recurrence by PET (TTR_PET) and by CT (TTR_CT) were determined and compared. FDG avidity of untreated tumors was compared between recurrent and non-recurrent groups. Thirteen recurrences after 72 RFA treatments were confirmed by diagnostic CT. All recurrences were associated with focally intense and increasing FDG uptake beyond 6 months (sensitivity 100%; specificity 98.5%). Mean TTR_PET was 14 months compared to mean TTR_CT of 17 months (not statistically significant). Normalized SUVmax and total lesions glycolysis of lung cancers that recurred after RFA was 4.0 and 6.0, respectively compared to 2.8 and 5.0, respectively for cancers that did not recur (p = .068). A pattern of focally intense and increasing FDG PET uptake has high sensitivity and specificity for detecting recurrent lung cancer following RFA. Surveillance after RFA should include a contrast enhanced diagnostic CT at 1 month to diagnose procedural complications, PET at 6 months as a post-treatment metabolic baseline (with diagnostic CT if PET is abnormal) and alternating diagnostic CTs or PET every 6 months for 2 years.

  8. Accuracy of computed tomographic features in differentiating intestinal tuberculosis from Crohn's disease: a systematic review with meta-analysis.

    PubMed

    Kedia, Saurabh; Sharma, Raju; Sreenivas, Vishnubhatla; Madhusudhan, Kumble Seetharama; Sharma, Vishal; Bopanna, Sawan; Pratap Mouli, Venigalla; Dhingra, Rajan; Yadav, Dawesh Prakash; Makharia, Govind; Ahuja, Vineet

    2017-04-01

    Abdominal computed tomography (CT) can noninvasively image the entire gastrointestinal tract and assess extraintestinal features that are important in differentiating Crohn's disease (CD) and intestinal tuberculosis (ITB). The present meta-analysis pooled the results of all studies on the role of CT abdomen in differentiating between CD and ITB. We searched PubMed and Embase for all publications in English that analyzed the features differentiating between CD and ITB on abdominal CT. The features included comb sign, necrotic lymph nodes, asymmetric bowel wall thickening, skip lesions, fibrofatty proliferation, mural stratification, ileocaecal area, long segment, and left colonic involvements. Sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio (DOR) were calculated for all the features. Symmetric receiver operating characteristic curve was plotted for features present in >3 studies. Heterogeneity and publication bias was assessed and sensitivity analysis was performed by excluding studies that compared features on conventional abdominal CT instead of CT enterography (CTE). We included 6 studies (4 CTE, 1 conventional abdominal CT, and 1 CTE+conventional abdominal CT) involving 417 and 195 patients with CD and ITB, respectively. Necrotic lymph nodes had the highest diagnostic accuracy (sensitivity, 23%; specificity, 100%; DOR, 30.2) for ITB diagnosis, and comb sign (sensitivity, 82%; specificity, 81%; DOR, 21.5) followed by skip lesions (sensitivity, 86%; specificity, 74%; DOR, 16.5) had the highest diagnostic accuracy for CD diagnosis. On sensitivity analysis, the diagnostic accuracy of other features excluding asymmetric bowel wall thickening remained similar. Necrotic lymph nodes and comb sign on abdominal CT had the best diagnostic accuracy in differentiating CD and ITB.

  9. ctDNA Determination of EGFR Mutation Status in European and Japanese Patients with Advanced NSCLC: The ASSESS Study.

    PubMed

    Reck, Martin; Hagiwara, Koichi; Han, Baohui; Tjulandin, Sergei; Grohé, Christian; Yokoi, Takashi; Morabito, Alessandro; Novello, Silvia; Arriola, Edurne; Molinier, Olivier; McCormack, Rose; Ratcliffe, Marianne; Normanno, Nicola

    2016-10-01

    To offer patients with EGFR mutation-positive advanced NSCLC appropriate EGFR tyrosine kinase inhibitor treatment, mutation testing of tumor samples is required. However, tissue/cytologic samples are not always available or evaluable. The large, noninterventional diagnostic ASSESS study (NCT01785888) evaluated the utility of circulating free tumor-derived DNA (ctDNA) from plasma for EGFR mutation testing. ASSESS was conducted in 56 centers (in Europe and Japan). Eligible patients (with newly diagnosed locally advanced/metastatic treatment-naive advanced NSCLC) provided diagnostic tissue/cytologic and plasma samples. DNA extracted from tissue/cytologic samples was subjected to EGFR mutation testing using local practices; designated laboratories performed DNA extraction/mutation testing of blood samples. The primary end point was level of concordance of EGFR mutation status between matched tissue/cytologic and plasma samples. Of 1311 patients enrolled, 1288 were eligible. Concordance of mutation status in 1162 matched samples was 89% (sensitivity 46%, specificity 97%, positive predictive value 78%, and negative predictive value 90%). A group of 25 patients with apparent false-positive plasma results was overrepresented for cytologic samples, use of less sensitive tissue testing methodologies, and smoking habits associated with high EGFR mutation frequency, indicative of false-negative tumor results. In cases in which plasma and tumor samples were tested with identical highly sensitive methods, positive predictive value/sensitivity were generally improved. These real-world data suggest that ctDNA is a feasible sample for EGFR mutation analysis. It is important to conduct mutation testing of both tumor and plasma samples in specialized laboratories, using robust/sensitive methods to ensure that patients receive appropriate treatments that target the molecular features of their disease. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  10. 123I-MIBG scintigraphy and 18F-FDG-PET imaging for diagnosing neuroblastoma.

    PubMed

    Bleeker, Gitta; Tytgat, Godelieve A M; Adam, Judit A; Caron, Huib N; Kremer, Leontien C M; Hooft, Lotty; van Dalen, Elvira C

    2015-09-29

    Neuroblastoma is an embryonic tumour of childhood that originates in the neural crest. It is the second most common extracranial malignant solid tumour of childhood.Neuroblastoma cells have the unique capacity to accumulate Iodine-123-metaiodobenzylguanidine (¹²³I-MIBG), which can be used for imaging the tumour. Moreover, ¹²³I-MIBG scintigraphy is not only important for the diagnosis of neuroblastoma, but also for staging and localization of skeletal lesions. If these are present, MIBG follow-up scans are used to assess the patient's response to therapy. However, the sensitivity and specificity of ¹²³I-MIBG scintigraphy to detect neuroblastoma varies according to the literature.Prognosis, treatment and response to therapy of patients with neuroblastoma are currently based on extension scoring of ¹²³I-MIBG scans. Due to its clinical use and importance, it is necessary to determine the exact diagnostic accuracy of ¹²³I-MIBG scintigraphy. In case the tumour is not MIBG avid, fluorine-18-fluorodeoxy-glucose ((18)F-FDG) positron emission tomography (PET) is often used and the diagnostic accuracy of this test should also be assessed. 1.1 To determine the diagnostic accuracy of ¹²³I-MIBG (single photon emission computed tomography (SPECT), with or without computed tomography (CT)) scintigraphy for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old.1.2 To determine the diagnostic accuracy of negative ¹²³I-MIBG scintigraphy in combination with (18)F-FDG-PET(-CT) imaging for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old, i.e. an add-on test. 2.1 To determine the diagnostic accuracy of (18)F-FDG-PET(-CT) imaging for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old.2.2 To compare the diagnostic accuracy of ¹²³I-MIBG (SPECT-CT) and (18)F-FDG-PET(-CT) imaging for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old. This was performed within and between included studies. ¹²³I-MIBG (SPECT-CT) scintigraphy was the comparator test in this case. We searched the databases of MEDLINE/PubMed (1945 to 11 September 2012) and EMBASE/Ovid (1980 to 11 September 2012) for potentially relevant articles. Also we checked the reference lists of relevant articles and review articles, scanned conference proceedings and searched for unpublished studies by contacting researchers involved in this area. We included studies of a cross-sectional design or cases series of proven neuroblastoma, either retrospective or prospective, if they compared the results of ¹²³I-MIBG (SPECT-CT) scintigraphy or (18)F-FDG-PET(-CT) imaging, or both, with the reference standards or with each other. Studies had to be primary diagnostic and report on children aged between 0 to 18 years old with a neuroblastoma of any stage at first diagnosis or at recurrence. One review author performed the initial screening of identified references. Two review authors independently performed the study selection, extracted data and assessed the methodological quality.We used data from two-by-two tables, describing at least the number of patients with a true positive test and the number of patients with a false negative test, to calculate the sensitivity, and if possible, the specificity for each included study.If possible, we generated forest plots showing estimates of sensitivity and specificity together with 95% confidence intervals. Eleven studies met the inclusion criteria. Ten studies reported data on patient level: the scan was positive or negative. One study reported on all single lesions (lesion level). The sensitivity of ¹²³I-MIBG (SPECT-CT) scintigraphy (objective 1.1), determined in 608 of 621 eligible patients included in the 11 studies, varied from 67% to 100%. One study, that reported on a lesion level, provided data to calculate the specificity: 68% in 115 lesions in 22 patients. The sensitivity of ¹²³I-MIBG scintigraphy for detecting metastases separately from the primary tumour in patients with all neuroblastoma stages ranged from 79% to 100% in three studies and the specificity ranged from 33% to 89% for two of these studies.One study reported on the diagnostic accuracy of (18)F-FDG-PET(-CT) imaging (add-on test) in patients with negative ¹²³I-MIBG scintigraphy (objective 1.2). Two of the 24 eligible patients with proven neuroblastoma had a negative ¹²³I-MIBG scan and a positive (18)F-FDG-PET(-CT) scan.The sensitivity of (18)F-FDG-PET(-CT) imaging as a single diagnostic test (objective 2.1) and compared to ¹²³I-MIBG (SPECT-CT) (objective 2.2) was only reported in one study. The sensitivity of (18)F-FDG-PET(-CT) imaging was 100% versus 92% of ¹²³I-MIBG (SPECT-CT) scintigraphy. We could not calculate the specificity for both modalities. The reported sensitivities of ¹²³-I MIBG scintigraphy for the detection of neuroblastoma and its metastases ranged from 67 to 100% in patients with histologically proven neuroblastoma.Only one study in this review reported on false positive findings. It is important to keep in mind that false positive findings can occur. For example, physiological uptake should be ruled out, by using SPECT-CT scans, although more research is needed before definitive conclusions can be made.As described both in the literature and in this review, in about 10% of the patients with histologically proven neuroblastoma the tumour does not accumulate ¹²³I-MIBG (false negative results). For these patients, it is advisable to perform an additional test for staging and assess response to therapy. Additional tests might for example be (18)F-FDG-PET(-CT), but to be certain of its clinical value, more evidence is needed.The diagnostic accuracy of (18)F-FDG-PET(-CT) imaging in case of a negative ¹²³I-MIBG scintigraphy could not be calculated, because only very limited data were available. Also the detection of the diagnostic accuracy of index test (18)F-FDG-PET(-CT) imaging for detecting a neuroblastoma tumour and its metastases, and to compare this to comparator test ¹²³I-MIBG (SPECT-CT) scintigraphy, could not be calculated because of the limited available data at time of this search.At the start of this project, we did not expect to find only very limited data on specificity. We now consider it would have been more appropriate to use the term "the sensitivity to assess the presence of neuroblastoma" instead of "diagnostic accuracy" for the objectives.

  11. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    PubMed

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  12. Optimal Monochromatic Energy Levels in Spectral CT Pulmonary Angiography for the Evaluation of Pulmonary Embolism

    PubMed Central

    Wu, Huawei; Zhang, Qing; Hua, Jia; Hua, Xiaolan; Xu, Jianrong

    2013-01-01

    Background The aim of this study was to determine the optimal monochromatic spectral CT pulmonary angiography (sCTPA) levels to obtain the highest image quality and diagnostic confidence for pulmonary embolism detection. Methods The Institutional Review Board of the Shanghai Jiao Tong University School of Medicine approved this study, and written informed consent was obtained from all participating patients. Seventy-two patients with pulmonary embolism were scanned with spectral CT mode in the arterial phase. One hundred and one sets of virtual monochromatic spectral (VMS) images were generated ranging from 40 keV to 140 keV. Image noise, clot diameter and clot to artery contrast-to-noise ratio (CNR) from seven sets of VMS images at selected monochromatic levels in sCTPA were measured and compared. Subjective image quality and diagnostic confidence for these images were also assessed and compared. Data were analyzed by paired t test and Wilcoxon rank sum test. Results The lowest noise and the highest image quality score for the VMS images were obtained at 65 keV. The VMS images at 65 keV also had the second highest CNR value behind that of 50 keV VMS images. There was no difference in the mean noise and CNR between the 65 keV and 70 keV VMS images. The apparent clot diameter correlated with the keV levels. Conclusions The optimal energy level for detecting pulmonary embolism using dual-energy spectral CT pulmonary angiography was 65–70 keV. Virtual monochromatic spectral images at approximately 65–70 keV yielded the lowest image noise, high CNR and highest diagnostic confidence for the detection of pulmonary embolism. PMID:23667583

  13. [Application of second generation dual-source computed tomography dual-energy scan mode in detecting pancreatic adenocarcinoma].

    PubMed

    Xue, Hua-dan; Liu, Wei; Sun, Hao; Wang, Xuan; Chen, Yu; Su, Bai-yan; Sun, Zhao-yong; Chen, Fang; Jin, Zheng-yu

    2010-12-01

    To analyze the clinical value of multiple sequences derived from dual-source computed tomography (DSCT) dual-energy scan mode in detecting pancreatic adenocarcinoma. Totally 23 patients with clinically or pathologically diagnosed pancreatic cancer were enrolled in this retrospective study. DSCT (Definition Flash) was used and dual-energy scan mode was used in their pancreatic parenchyma phase scan (100kVp/230mAs and Sn140kVp/178mAs) . Mono-energetic 60kev, mono-energetic 80kev, mono-energetic 100kev, mono-energetic 120kev, linear blend image, non-linear blend image, and iodine map were acquired. pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were calculated. One-way ANOVA was used for the comparison of diagnostic values of the above eight different dual-energy derived sequences for pancreatic cancer. The pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were significantly different among eight sequences (P<0.05) . Mono-energetic 60kev image showed the largest parenchyma-tumor CT value [ (77.53 ± 23.42) HU] , and iodine map showed the lowest tumor/parenchyma enhancement ratio (0.39?0.12) and the largest contrast to noise ratio (4.08 ± 1.46) . Multiple sequences can be derived from dual-energy scan mode with DSCT via multiple post-processing methods. Integration of these sequences may further improve the sensitivity of the multislice spiral CT in the diagnosis of pancreatic cancer.

  14. SU-E-P-08: Establishment of Local Diagnostic Reference Levels of Routine Abdomen Exam in Computed Tomography According to Body Weight

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, H; Wang, Y; Weng, H

    Purpose: The national diagnostic reference levels (NDRLs) is an efficient, concise and powerful standard for optimizing radiation protection of a patient. However, for each hospital the dose-reducing potential of focusing on establishment of local DRLs (LDRLs). A lot of study reported that Computed tomography exam contributed majority radiation dose in different medical modalities, therefore, routine abdomen CT exam was choose in initial pilot study in our study. Besides the mAs of routine abdomen CT exam was decided automatic exposure control by linear attenuation is relate to body shape of patient. In this study we would like to establish the localmore » diagnostic reference levels of routine abdomen exam in computed tomography according to body weight of patient. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). The patient sample involved 82 adult patients of both sexes and divided into three groups by their body weight (50–60 kg, 60–70 kg, 70–80 kg).Carried out the routine abdomen examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. The average values were compared with the European DRLs. Results: The majority of patients (75%) were between 50–70 Kg of body weight, the numbers of patient in each group of weight were 40–50:7; 50–60:29; 60–70:33; 70–80:13. The LDRLs in each group were 10.81mGy, 14.46mGy, 20.27mGy and 21.04mGy, respectively. The DLP were 477mGy, 630mGy, 887mGy and 959mGy, respectively. No matter which group the LDRLs were lower than European DRLs. Conclusions: We would like to state that this was a pioneer work in local hospital in Chiayi. We hope that this may lead the way to further developments in Taiwan.« less

  15. CT-guided robotically-assisted infiltration of foot and ankle joints.

    PubMed

    Wiewiorski, Martin; Valderrabano, Victor; Kretzschmar, Martin; Rasch, Helmut; Markus, Tanja; Dziergwa, Severine; Kos, Sebastian; Bilecen, Deniz; Jacob, Augustinus Ludwig

    2009-01-01

    It was our aim to describe a CT-guided robotically-assisted infiltration technique for diagnostic injections in foot and ankle orthopaedics. CT-guided mechatronically-assisted joint infiltration was performed on 16 patients referred to the orthopaedic department for diagnostic foot and ankle assessment. All interventions were performed using an INNOMOTION-assistance device on a multislice CT scanner in an image-guided therapy suite. Successful infiltration was defined as CT localization of contrast media in the target joint. Additionally, pre- and post-interventional VAS pain scores were assessed. All injections (16/16 joints) were technically successful. Contrast media deposit was documented in all targeted joints. Significant relief of pain was noted by all 16 patients (p<0.01). CT-guided robotically-assisted intervention is an exact, reliable and safe application method for diagnostic infiltration of midfoot and hindfoot joints. The high accuracy and feasibility in a clinical environment make it a viable alternative to the commonly used fluoroscopic-guided procedures.

  16. FDG-PET/CT Limited to the Thorax and Upper Abdomen for Staging and Management of Lung Cancer.

    PubMed

    Arens, Anne I J; Postema, Jan W A; Schreurs, Wendy M J; Lafeber, Albert; Hendrickx, Baudewijn W; Oyen, Wim J G; Vogel, Wouter V

    2016-01-01

    This study evaluates the diagnostic accuracy of [F-18]-fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) of the chest/upper abdomen compared to the generally performed scan from head to upper thighs, for staging and management of (suspected) lung cancer in patients with no history of malignancy or complaints outside the thorax. FDG-PET/CT scans of 1059 patients with suspected or recently proven lung cancer, with no history of malignancy or complaints outside the thorax, were analysed in a retrospective multi-centre trial. Suspect FDG-avid lesions in the chest and upper abdomen, the head and neck area above the shoulder line and in the abdomen and pelvis below the caudal tip of the liver were noted. The impact of lesions detected in the head and neck area and abdomen and pelvis on additional diagnostic procedures, staging and treatment decisions was evaluated. The head and neck area revealed additional suspect lesions in 7.2%, and the abdomen and pelvis in 15.8% of patients. Imaging of the head and neck area and the abdomen and pelvic area showed additional lesions in 19.5%, inducing additional diagnostic procedures in 7.8%. This resulted in discovery of additional lesions considered malignant in 10.7%, changing patient management for lung cancer in 1.2%. In (suspected) lung cancer, PET/CT limited to the chest and upper abdomen resulted in correct staging in 98.7% of patients, which led to the identical management as full field of view PET in 98.8% of patients. High value of FDG-PET/CT for staging and correct patient management is already achieved with chest and upper abdomen. Findings in head and neck area and abdomen and pelvis generally induce investigations with limited or no impact on staging and treatment of NSCLC, and can be interpreted accordingly.

  17. Rhinoceros Feet Step Out of a Rule-of-Thumb: A Wildlife Imaging Pioneering Approach of Synchronized Computed Tomography-Digital Radiography

    PubMed Central

    Saragusty, Joseph; Göritz, Frank; Potier, Romain; Mulot, Baptiste; Maillot, Alexis; Etienne, Pascal; Bernardino, Rui; Fernandes, Teresa; Mews, Jurgen; Hildebrandt, Thomas Bernd

    2014-01-01

    Currently, radiography is the only imaging technique used to diagnose bone pathology in wild animals situated under “field conditions”. Nevertheless, while chronic foot disease in captive mega-herbivores is widely reported, foot radiographic imaging is confronted with scarcity of studies. Numerous hindrances lead to such limited numbers and it became very clear that the traditional perspective on bone imaging in domestic animals based on extensive studies and elaborated statistical evaluations cannot be extrapolated to their non-domestic relatives. For these reasons, the authors initiated a multi-modality imaging study and established a pioneering approach of synchronized computed tomography (CT) and digital radiography (DR), based on X-ray projections derived from three-dimensional CT reconstructed images. Whereas this approach can be applied in any clinical field, as a case of outstanding importance and great concern for zoological institutions, we selected foot bone pathologies in captive rhinoceroses to demonstrate the manifold applications of the method. Several advances were achieved, endowing the wildlife clinician with all-important tools: prototype DR exposure protocols and a modus operandi for foot positioning, advancing both traditional projections and, for the first-time, species-related radiographic views; assessment of radiographic diagnostic value for the whole foot and, in premiere, for each autopodial bone; together with additional insights into radiographic appearance of bone anatomy and pathology with a unique, simultaneous CT-DR correlation. Based on its main advantages in availing a wide range of keystone data in wildlife imaging from a limited number of examined subjects and combining advantages of CT as the golden standard method for bone diseases' diagnostic with DR's clinical feasibility under field conditions, synchronized CT-DR presents a new perspective on wildlife's health management. With this we hope to provide veterinary clinicians with concrete imaging techniques and substantial diagnostic tools, which facilitate straightforward attainment and interpretation of field radiography images taken worldwide. PMID:24963807

  18. Rhinoceros feet step out of a rule-of-thumb: a wildlife imaging pioneering approach of synchronized computed tomography-digital radiography.

    PubMed

    Galateanu, Gabriela; Hermes, Robert; Saragusty, Joseph; Göritz, Frank; Potier, Romain; Mulot, Baptiste; Maillot, Alexis; Etienne, Pascal; Bernardino, Rui; Fernandes, Teresa; Mews, Jurgen; Hildebrandt, Thomas Bernd

    2014-01-01

    Currently, radiography is the only imaging technique used to diagnose bone pathology in wild animals situated under "field conditions". Nevertheless, while chronic foot disease in captive mega-herbivores is widely reported, foot radiographic imaging is confronted with scarcity of studies. Numerous hindrances lead to such limited numbers and it became very clear that the traditional perspective on bone imaging in domestic animals based on extensive studies and elaborated statistical evaluations cannot be extrapolated to their non-domestic relatives. For these reasons, the authors initiated a multi-modality imaging study and established a pioneering approach of synchronized computed tomography (CT) and digital radiography (DR), based on X-ray projections derived from three-dimensional CT reconstructed images. Whereas this approach can be applied in any clinical field, as a case of outstanding importance and great concern for zoological institutions, we selected foot bone pathologies in captive rhinoceroses to demonstrate the manifold applications of the method. Several advances were achieved, endowing the wildlife clinician with all-important tools: prototype DR exposure protocols and a modus operandi for foot positioning, advancing both traditional projections and, for the first-time, species-related radiographic views; assessment of radiographic diagnostic value for the whole foot and, in premiere, for each autopodial bone; together with additional insights into radiographic appearance of bone anatomy and pathology with a unique, simultaneous CT-DR correlation. Based on its main advantages in availing a wide range of keystone data in wildlife imaging from a limited number of examined subjects and combining advantages of CT as the golden standard method for bone diseases' diagnostic with DR's clinical feasibility under field conditions, synchronized CT-DR presents a new perspective on wildlife's health management. With this we hope to provide veterinary clinicians with concrete imaging techniques and substantial diagnostic tools, which facilitate straightforward attainment and interpretation of field radiography images taken worldwide.

  19. Recommendations on nuclear and multimodality imaging in IE and CIED infections.

    PubMed

    Erba, Paola Anna; Lancellotti, Patrizio; Vilacosta, Isidre; Gaemperli, Oliver; Rouzet, Francois; Hacker, Marcus; Signore, Alberto; Slart, Riemer H J A; Habib, Gilbert

    2018-05-24

    In the latest update of the European Society of Cardiology (ESC) guidelines for the management of infective endocarditis (IE), imaging is positioned at the centre of the diagnostic work-up so that an early and accurate diagnosis can be reached. Besides echocardiography, contrast-enhanced CT (ce-CT), radiolabelled leucocyte (white blood cell, WBC) SPECT/CT and [ 18 F]FDG PET/CT are included as diagnostic tools in the diagnostic flow chart for IE. Following the clinical guidelines that provided a straightforward message on the role of multimodality imaging, we believe that it is highly relevant to produce specific recommendations on nuclear multimodality imaging in IE and cardiac implantable electronic device infections. In these procedural recommendations we therefore describe in detail the technical and practical aspects of WBC SPECT/CT and [ 18 F]FDG PET/CT, including ce-CT acquisition protocols. We also discuss the advantages and limitations of each procedure, specific pitfalls when interpreting images, and the most important results from the literature, and also provide recommendations on the appropriate use of multimodality imaging.

  20. Comparison of virtual unenhanced CT images of the abdomen under different iodine flow rates.

    PubMed

    Li, Yongrui; Li, Ye; Jackson, Alan; Li, Xiaodong; Huang, Ning; Guo, Chunjie; Zhang, Huimao

    2017-01-01

    To assess the effect of varying iodine flow rate (IFR) and iodine concentration on the quality of virtual unenhanced (VUE) images of the abdomen obtained with dual-energy CT. 94 subjects underwent unenhanced and triphasic contrast-enhanced CT scan of the abdomen, including arterial phase, portal venous phase, and delayed phase using dual-energy CT. Patients were randomized into 4 groups with different IFRs or iodine concentrations. VUE images were generated at 70 keV. The CT values, image noise, SNR and CNR of aorta, portal vein, liver, liver lesion, pancreatic parenchyma, spleen, erector spinae, and retroperitoneal fat were recorded. Dose-length product and effective dose for an examination with and without plain phase scan were calculated to assess the potential dose savings. Two radiologists independently assessed subjective image quality using a five-point scale. The Kolmogorov-Smirnov test was used first to test for normal distribution. Where data conformed to a normal distribution, analysis of variance was used to compare mean HU values, image noise, SNRs and CNRs for the 4 image sets. Where data distribution was not normal, a nonparametric test (Kruskal-Wallis test followed by stepwise step-down comparisons) was used. The significance level for all tests was 0.01 (two-sided) to allow for type 2 errors due to multiple testing. The CT numbers (HU) of VUE images showed no significant differences between the 4 groups (p > 0.05) or between different phases within the same group (p > 0.05). VUE images had equal or higher SNR and CNR than true unenhanced images. VUE images received equal or lower subjective image quality scores than unenhanced images but were of acceptable quality for diagnostic use. Calculated dose-length product and estimated dose showed that the use of VUE images in place of unenhanced images would be associated with a dose saving of 25%. VUE images can replace conventional unenhanced images. VUE images are not affected by varying iodine flow rates and iodine concentrations, and diagnostic examinations could be acquired with a potential dose saving of 25%.

  1. The Value of 18F-FDG PET/CT Mathematical Prediction Model in Diagnosis of Solitary Pulmonary Nodules

    PubMed Central

    Chen, Yao; Tang, Kun; Lin, Jie

    2018-01-01

    Purpose To establish an 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) mathematical prediction model to improve the diagnosis of solitary pulmonary nodules (SPNs). Materials and Methods We retrospectively reviewed 177 consecutive patients who underwent 18F-FDG PET/CT for evaluation of SPNs. The mathematical model was established by logistic regression analysis. The diagnostic capabilities of the model were calculated, and the areas under the receiver operating characteristic curve (AUC) were compared with Mayo and VA model. Results The mathematical model was y = exp⁡(x)/[1 + exp⁡(x)], x = −7.363 + 0.079 × age + 1.900 × lobulation + 1.024 × vascular convergence + 1.530 × pleural retraction + 0.359 × the maximum of standardized uptake value (SUVmax). When the cut-off value was set at 0.56, the sensitivity, specificity, and accuracy of our model were 86.55%, 74.14%, and 81.4%, respectively. The area under the receiver operating characteristic curve (AUC) of our model was 0.903 (95% confidence interval (CI): 0.860 to 0.946). The AUC of our model was greater than that of the Mayo model, the VA model, and PET (P < 0.05) and has no difference with that of PET/CT (P > 0.05). Conclusion The mathematical predictive model has high accuracy in estimating the malignant probability of patients with SPNs. PMID:29789808

  2. The diagnostic challenge of the sequelae of acute pancreatitis on CT imaging: a pictorial essay.

    PubMed

    Hughey, Mark; Taffel, Myles; Zeman, Robert K; Patel, Smita; Hill, Michael C

    2017-04-01

    The purpose of the study was to present a pictorial review of the long-term sequelae of acute pancreatitis on CT imaging as these findings can cause diagnostic confusion in the absence of a proper clinical history and/or prior CT imaging. We retrospectively identified 81 patients who had an episode of acute pancreatitis with diagnostic findings on CT and also underwent one or more follow-up CT scans at least 1 month beyond the acute episode. The residual findings on all follow-up CT scans were tabulated, including the time interval since the initial bout of acute pancreatitis. Residual inflammatory changes were present in 19.8% of cases, with a median time period lasting 86 days since the initial episode of acute pancreatitis. Residual fluid collections were seen in 27.2% and persisted for a median of 132 days. Three patients had residual solid-appearing inflammatory masses, which could be mistaken for neoplasms. Other long-term sequelae were also tabulated, including pancreatic ductal dilatation, pancreatic atrophy, new or increased pancreatic calcifications, biliary tract dilatation, central portal venous occlusion, and pseudoaneurysm formation. These residual findings and long-term complications are presented as a pictorial essay. Recognizing the spectrum of residual findings of acute pancreatitis, some of which can be long term, is important in the correct interpretation of a pancreatic CT. These findings can mimic acute pancreatitis or a pancreatic/peripancreatic neoplasm and often cause diagnostic confusion, especially in the absence of prior CT imaging.

  3. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % inmore » drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.« less

  4. The value of FDG positron emission tomography/computerised tomography (PET/CT) in pre-operative staging of colorectal cancer: a systematic review and economic evaluation.

    PubMed

    Brush, J; Boyd, K; Chappell, F; Crawford, F; Dozier, M; Fenwick, E; Glanville, J; McIntosh, H; Renehan, A; Weller, D; Dunlop, M

    2011-09-01

    In the UK, colorectal cancer (CRC) is the third most common malignancy (behind lung and breast cancer) with 37,514 cases registered in 2006: around two-thirds (23,384) in the colon and one-third (14,130) in the rectum. Treatment of cancers of the colon can vary considerably, but surgical resection is the mainstay of treatment for curative intent. Following surgical resection, there is a comprehensive assessment of the tumour, it's invasion characteristics and spread (tumour staging). A number of imaging modalities are used in the pre-operative staging of CRCs including; computerised tomography (CT), magnetic resonance imaging, ultrasound imaging and positron emission tomography (PET). This report examines the role of CT in combination with PET scanning (PET/CT 'hybrid' scan). The research objectives are: to evaluate the diagnostic accuracy and therapeutic impact of fluorine-18-deoxyglucose (FDG) PET/CT for the pre-operative staging of primary, recurrent and metastatic cancer using systematic review methods; undertake probabilistic decision-analytic modelling (using Monte Carlo simulation); and conduct a value of information analysis to help inform whether or not there is potential worth in undertaking further research. For each aspect of the research - the systematic review, the handsearch study and the economic evaluation - a database was assembled from a comprehensive search for published and unpublished studies, which included database searches, reference lists search and contact with experts. In the systematic review prospective and retrospective patient series (diagnostic cohort) and randomised controlled trials (RCTs) were eligible for inclusion. Both consecutive series and series that are not explicitly reported as consecutive were included. Two reviewers extracted all data and applied the criteria independently and resolved disagreements by discussion. Data to populate 2 × 2 contingency tables consisting of the number of true positives, true negatives, false positives and false negatives using the studies' own definitions were extracted, as were data relating to changes in management. Fourteen items from the Quality Assessment of Diagnostic Accuracy Studies checklist were used to assess the methodological quality of the included studies. Patient-level data were used to calculate sensitivity and specificity with confidence intervals (CIs). Data were plotted graphically in forest plots. For the economic evaluation, economic models were designed for each of the disease states: primary, recurrent and metastatic. These were developed and populated based on a variety of information sources (in particular from published data sources) and literature, and in consultation with clinical experts. The review found 30 studies that met the eligibility criteria. Only two small studies evaluated the use of FDG PET/CT in primary CRC, and there is insufficient evidence to support its routine use at this time. The use of FDG PET/CT for the detection of recurrent disease identified data from five retrospective studies from which a pooled sensitivity of 91% (95% CI 0.87% to 0.95%) and specificity of 91% (95% CI 0.85% to 0.95%) were observed. Pooled accuracy data from patients undergoing staging for suspected metastatic disease showed FDG PET/CT to have a pooled sensitivity of 91% (95% CI 87% to 94%) and a specificity of 76% (95% CI 58% to 88%), but the poor quality of the studies means the validity of the data may be compromised by several biases. The separate handsearch study did not yield any additional unique studies relevant to FDG PET/CT. Models for recurrent disease demonstrated an incremental cost-effectiveness ratio of £ 21,409 per quality-adjusted life-year (QALY) for rectal cancer, £ 6189 per QALY for colon cancer and £ 21,434 per QALY for metastatic disease. The value of handsearching to identify studies of less clearly defined or reported diagnostic tests is still to be investigated. The systematic review found insufficient evidence to support the routine use of FDG PET/CT in primary CRC and only a small amount of evidence supporting its use in the pre-operative staging of recurrent and metastatic CRC, and, although FDG PET/CT was shown to change patient management, the data are divergent and the quality of research is generally poor. The handsearch to identify studies of less clearly defined or reported diagnostic tests did not find additional studies. The primary limitations in the economic evaluations were due to uncertainty and lack of available evidence from the systematic reviews for key parameters in each of the five models. In order to address this, a conservative approach was adopted in choosing DTA estimates for the model parameters. Probabilistic analyses were undertaken for each of the models, incorporating wide levels of uncertainty particularly for the DTA estimates. None of the economic models reported cost-savings, but the approach adopted was conservative in order to determine more reliable results given the lack of current information. The economic evaluations conclude that FDG PET/CT as an add-on imaging device is cost-effective in the pre-operative staging of recurrent colon, recurrent rectal and metastatic disease but not in primary colon or rectal cancers. There would be value in undertaking an RCT with a concurrent economic evaluation to evaluate the therapeutic impact and cost-effectiveness of FDG PET/CT compared with conventional imaging (without PET) for the pre-operative staging of recurrent and metastatic CRC.

  5. Percutaneous foot joint needle placement using a C-arm flat-panel detector CT.

    PubMed

    Wiewiorski, Martin; Takes, Martin Thanh Long; Valderrabano, Victor; Jacob, Augustinus Ludwig

    2012-03-01

    Image guidance is valuable for diagnostic injections in foot orthopaedics. Flat-detector computed tomography (FD-CT) was implemented using a C-arm, and the system was tested for needle guidance in foot joint injections. FD-CT-guided joint infiltration was performed in 6 patients referred from the orthopaedic department for diagnostic foot injections. All interventions were performed utilising a flat-panel fluoroscopy system utilising specialised image guidance and planning software. Successful infiltration was defined by localisation of contrast media depot in the targeted joint. The pre- and post-interventional numeric analogue scale (NAS) pain score was assessed. All injections were technically successful. Contrast media deposit was documented in all targeted joints. Significant relief of symptoms was noted by all 6 participants. FD-CT-guided joint infiltration is a feasible method for diagnostic infiltration of midfoot and hindfoot joints. The FD-CT approach may become an alternative to commonly used 2D-fluoroscopically guidance.

  6. Radiation dose reduction in parasinus CT by spectral shaping.

    PubMed

    May, Matthias S; Brand, Michael; Lell, Michael M; Sedlmair, Martin; Allmendinger, Thomas; Uder, Michael; Wuest, Wolfgang

    2017-02-01

    Spectral shaping aims to narrow the X-ray spectrum of clinical CT. The aim of this study was to determine the image quality and the extent of radiation dose reduction that can be achieved by tin prefiltration for parasinus CT. All scans were performed with a third generation dual-source CT scanner. A study protocol was designed using 100 kV tube voltage with tin prefiltration (200 mAs) that provides image noise levels comparable to a low-dose reference protocol using 100 kV without spectral shaping (25 mAs). One hundred consecutive patients were prospectively enrolled and randomly assigned to the study or control group. All patients signed written informed consent. The study protocol was approved by the local Institutional Review Board and applies to the HIPAA. Subjective and objective image quality (attenuation values, image noise, and contrast-to-noise ratio (CNR)) were assessed. Radiation exposure was assessed as volumetric CT dose index, and effective dose was estimated. Mann-Whitney U test was performed for radiation exposure and for image noise comparison. All scans were of diagnostic image quality. Image noise in air, in the retrobulbar fat, and in the eye globe was comparable between both groups (all p > 0.05). CNR eye globe/air did not differ significantly between both groups (p = 0.7). Radiation exposure (1.7 vs. 2.1 mGy, p < 0.01) and effective dose (0.055 vs. 0.066 mSv, p < 0.01) were significantly reduced in the study group. Radiation dose can be further reduced by 17% for low-dose parasinus CT by tin prefiltration maintaining diagnostic image quality.

  7. Measurement of small lesions near metallic implants with mega-voltage cone beam CT

    NASA Astrophysics Data System (ADS)

    Grigorescu, Violeta; Prevrhal, Sven; Pouliot, Jean

    2008-03-01

    Metallic objects severely limit diagnostic CT imaging because of their high X-ray attenuation in the diagnostic energy range. In contrast, radiation therapy linear accelerators now offer CT imaging with X-ray energies in the megavolt range, where the attenuation coefficients of metals are significantly lower. We hypothesized that Mega electron-Voltage Cone-Beam CT (MVCT) implemented on a radiation therapy linear accelerator can detect and quantify small features in the vicinity of metallic implants with accuracy comparable to clinical Kilo electron-Voltage CT (KVCT) for imaging. Our test application was detection of osteolytic lesions formed near the metallic stem of a hip prosthesis, a condition of severe concern in hip replacement surgery. Both MVCT and KVCT were used to image a phantom containing simulated osteolytic bone lesions centered around a Chrome-Cobalt hip prosthesis stem with hemispherical lesions with sizes and densities ranging from 0.5 to 4 mm radius and 0 to 500 mg•cm -3, respectively. Images for both modalities were visually graded to establish lower limits of lesion visibility as a function of their size. Lesion volumes and mean density were determined and compared to reference values. Volume determination errors were reduced from 34%, on KVCT, to 20% for all lesions on MVCT, and density determination errors were reduced from 71% on KVCT to 10% on MVCT. Localization and quantification of lesions was improved with MVCT imaging. MVCT offers a viable alternative to clinical CT in cases where accurate 3D imaging of small features near metallic hardware is critical. These results need to be extended to other metallic objects of different composition and geometry.

  8. Diagnostic efficacy of the Liver Imaging-Reporting and Data System (LI-RADS) with CT imaging in categorising small nodules (10-20 mm) detected in the cirrhotic liver at screening ultrasound.

    PubMed

    Abd Alkhalik Basha, M; Abd El Aziz El Sammak, D; El Sammak, A A

    2017-10-01

    To estimate the diagnostic accuracy of the Liver Imaging-Reporting and Data System (LI-RADS) with computed tomography (CT) for diagnosing hepatic nodules (10-20 mm) detected in cirrhotic livers. Fifty-five patients with liver cirrhosis and a solitary nodule (10-20 mm in diameter) detected via ultrasound surveillance, underwent hepatic CT and fine-needle biopsy. All the CT images were analysed and the lesions were categorised into five categories according to the LI-RADS. Final diagnoses of the 55 nodules were as follows: 34 hepatocellular carcinomas (HCCs), one intrahepatic cholangiocarcinomas, one adrenocortical carcinoma metastasis, and 19 benign lesions. None (0%) of four LI-RADS category 1 lesions, two (22%) of nine category 2 lesions, seven (50%) of 14 category 3 lesions, two (67%) of three category 4 lesions, 22 (96%) of 23 category 5 lesions and one (50%) of two lesions classified as other malignancies was HCC. One category 5 lesion was adrenocortical carcinoma metastasis and one of two lesions categorised as other malignancies was intrahepatic cholangiocarcinoma. In patients with nodules detected at surveillance ultrasound, the best threshold for confident HCC diagnosis was more than LI-RADS category 3. The use of this threshold produced a sensitivity and specificity of 72.7% and 90%, respectively. So combining LI-RADS 4 and 5 categories for confident HCC diagnosis would improve accuracy and sensitivity with no significant impairment of specificity or positive predictive value. LIRADS with CT provides a strong validity for the diagnosis of small hepatic nodules, and is very useful to improve the accuracy of CT reports. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Assessment of noise reduction potential and image quality improvement of a new generation adaptive statistical iterative reconstruction (ASIR-V) in chest CT.

    PubMed

    Tang, Hui; Yu, Nan; Jia, Yongjun; Yu, Yong; Duan, Haifeng; Han, Dong; Ma, Guangming; Ren, Chenglong; He, Taiping

    2018-01-01

    To evaluate the image quality improvement and noise reduction in routine dose, non-enhanced chest CT imaging by using a new generation adaptive statistical iterative reconstruction (ASIR-V) in comparison with ASIR algorithm. 30 patients who underwent routine dose, non-enhanced chest CT using GE Discovery CT750HU (GE Healthcare, Waukesha, WI) were included. The scan parameters included tube voltage of 120 kVp, automatic tube current modulation to obtain a noise index of 14HU, rotation speed of 0.6 s, pitch of 1.375:1 and slice thickness of 5 mm. After scanning, all scans were reconstructed with the recommended level of 40%ASIR for comparison purpose and different percentages of ASIR-V from 10% to 100% in a 10% increment. The CT attenuation values and SD of the subcutaneous fat, back muscle and descending aorta were measured at the level of tracheal carina of all reconstructed images. The signal-to-noise ratio (SNR) was calculated with SD representing image noise. The subjective image quality was independently evaluated by two experienced radiologists. For all ASIR-V images, the objective image noise (SD) of fat, muscle and aorta decreased and SNR increased along with increasing ASIR-V percentage. The SD of 30% ASIR-V to 100% ASIR-V was significantly lower than that of 40% ASIR (p < 0.05). In terms of subjective image evaluation, all ASIR-V reconstructions had good diagnostic acceptability. However, the 50% ASIR-V to 70% ASIR-V series showed significantly superior visibility of small structures when compared with the 40% ASIR and ASIR-V of other percentages (p < 0.05), and 60% ASIR-V was the best series of all ASIR-V images, with a highest subjective image quality. The image sharpness was significantly decreased in images reconstructed by 80% ASIR-V and higher. In routine dose, non-enhanced chest CT, ASIR-V shows greater potential in reducing image noise and artefacts and maintaining image sharpness when compared to the recommended level of 40%ASIR algorithm. Combining both the objective and subjective evaluation of images, non-enhanced chest CT images reconstructed with 60% ASIR-V have the highest image quality. Advances in knowledge: This is the first clinical study to evaluate the clinical value of ASIR-V in the same patients using the same CT scanner in the non-enhanced chest CT scans. It suggests that ASIR-V provides the better image quality and higher diagnostic confidence in comparison with ASIR algorithm.

  10. Dual energy spectral CT imaging for the evaluation of small hepatocellular carcinoma microvascular invasion.

    PubMed

    Yang, Chuang-Bo; Zhang, Shuang; Jia, Yong-Jun; Yu, Yong; Duan, Hai-Feng; Zhang, Xi-Rong; Ma, Guang-Ming; Ren, Chenglong; Yu, Nan

    2017-10-01

    To study the clinical value of dual-energy spectral CT in the quantitative assessment of microvascular invasion of small hepatocellular carcinoma. This study was approved by our ethics committee. 50 patients with small hepatocellular carcinoma who underwent contrast enhanced spectral CT in arterial phase (AP) and portal venous phase (VP) were enrolled. Tumour CT value and iodine concentration (IC) were measured from spectral CT images. The slope of spectral curve, normalized iodine concentration (NIC, to abdominal aorta) and ratio of IC difference between AP and VP (RIC AP-VP : [RIC AP-VP =(IC AP -IC VP )/IC AP ]) were calculated. Tumours were identified as either with or without microvascular invasion based on pathological results. Measurements were statistically compared using independent samples t test. The receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic performance of tumours microvascular invasion assessment. The 70keV images were used to simulate the results of conventional CT scans for comparison. 56 small hepatocellular carcinomas were detected with 37 lesions (Group A) with microvascular invasion and 19 (Group B) without. There were significant differences in IC, NIC and slope in AP and RIC AP-VP between Group A (2.48±0.70mg/ml, 0.23±0.05, 3.39±1.01 and 0.28±0.16) and Group B (1.65±0.47mg/ml, 0.15±0.05, 2.22±0.64 and 0.03±0.24) (all p<0.05). Using 0.188 as the threshold for NIC, one could obtain an area-under-curve (AUC) of 0.87 in ROC to differentiate between tumours with and without microvascular invasion. AUC was 0.71 with CT value at 70keV and improved to 0.81 at 40keV. Dual-energy Spectral CT provides additional quantitative parameters than conventional CT to improve the differentiation between small hepatocellular carcinoma with and without microvascular invasion. Quantitative iodine concentration measurement in spectral CT may be used to provide a new method to improve the evaluation for small hepatocellular carcinoma microvascular invasion. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Computed tomography scan diagnosis of occult groin hernia.

    PubMed

    Garvey, J F W

    2012-06-01

    The value of computed tomography (CT) for the diagnosis of clinically occult (hidden) groin hernia was assessed in a series of patients presenting with undiagnosed groin pain. A total of 158 consecutive patients presenting over a period of 5 years with undiagnosed groin pain or lower abdominal pain and negative or equivocal clinical findings were radiologically assessed with non-contrast CT. The decision to manage operatively or conservatively was then based on a combination of the clinical and CT findings. Outcomes were assessed at 10 years follow-up. The study cohort comprised 158 patients presenting with groin or lower abdominal pain and/or swelling, and was studied prospectively. Seven of these patients were re-investigated at a later date after developing new pain on either the ipsilateral or contralateral side, giving a total of 165 CT examinations. One-third of cases (54) had clinically occult groin hernias and most of the remaining cases had diagnoses that could be managed non-operatively. Of those who came to surgery, the pre-operative CT diagnosis of hernia had a positive predictive value (PPV) of 92% and a negative predictive value (NPV) of 96% (overall accuracy 94%). Lipoma of the spermatic cord was responsible for three of five false-positive CT results. The concept of sports hernia/groin disruption injury (GDI) was encountered, and this entity is discussed in this paper. In the group of patients without hernia findings on CT, the most common diagnoses were rectus abdominis and/or pyramidalis muscle injury which could be treated by physiotherapy (22%), GDI (16%), post-surgical problems (14%), miscellaneous (20%) and 'no abnormality' was identified in 15%. Overall, there were 111 patients with a 'non-hernia' CT diagnosis, of which urological, gynaecological, gastrointestinal and neuralgia contributed to the non-musculoskeletal diagnosis. This prospective non-contrast CT study of patients with undiagnosed chronic groin pain detected the majority of occult hernias requiring surgical intervention. These results suggest that CT can be a useful adjunct to the evaluation of patients presenting with chronic undiagnosed groin pain, but that experienced clinical judgment remains a critical element in the diagnostic pathway.

  12. Deformable image registration for multimodal lung-cancer staging

    NASA Astrophysics Data System (ADS)

    Cheirsilp, Ronnarit; Zang, Xiaonan; Bascom, Rebecca; Allen, Thomas W.; Mahraj, Rickhesvar P. M.; Higgins, William E.

    2016-03-01

    Positron emission tomography (PET) and X-ray computed tomography (CT) serve as major diagnostic imaging modalities in the lung-cancer staging process. Modern scanners provide co-registered whole-body PET/CT studies, collected while the patient breathes freely, and high-resolution chest CT scans, collected under a brief patient breath hold. Unfortunately, no method exists for registering a PET/CT study into the space of a high-resolution chest CT scan. If this could be done, vital diagnostic information offered by the PET/CT study could be brought seamlessly into the procedure plan used during live cancer-staging bronchoscopy. We propose a method for the deformable registration of whole-body PET/CT data into the space of a high-resolution chest CT study. We then demonstrate its potential for procedure planning and subsequent use in multimodal image-guided bronchoscopy.

  13. Simulation of computed tomography dose based on voxel phantom

    NASA Astrophysics Data System (ADS)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  14. Pitfalls of CT for deep neck abscess imaging assessment: a retrospective review of 162 cases.

    PubMed

    Chuang, S Y; Lin, H T; Wen, Y S; Hsu, F J

    2013-01-01

    To investigate the diagnostic value of contrast-enhanced computed tomography (CT) for the prediction of deep neck abscesses in different deep neck spaces and to evaluate the false-positive results. We retrospectively analysed the clinical charts, CT examinations, surgical findings, bacteriology, pathological examinations and complications of hospitalised patients with a diagnosis of deep neck abscess from 2004 to 2010. The positive predictive values (PPV) for the prediction of abscesses by CT scan in different deep neck spaces were calculated individually on the basis of surgical findings. A total of 162 patients were included in this study. All patients received both intravenous antibiotics and surgical drainage. The parapharyngeal space was the most commonly involved space. The overall PPV for the prediction of deep neck abscess with contrast-enhanced CT was 79.6%. The PPV was 91.3% when more than one deep neck space was involved but only 50.0% in patients with isolated retropharyngeal abscesses. In the false-positive group, cellulitis was the most common final result, followed by cystic degeneration of cervical metastases. Five specimens taken intra-operatively revealed malignancy and four of these were not infected. There are some limitations affecting the differentiation of abscesses and cellulitis, particularly in the retropharyngeal space. A central necrotic cervical metastatic lymph node may sometimes also mimic a simple pyogenic deep neck abscess on both clinical pictures and CT images. Routine biopsy of the tissue must be performed during surgical drainage.

  15. CT biliary cystoscopy of gallbladder polyps

    PubMed Central

    Lou, Ming-Wu; Hu, Wei-Dong; Fan, Yi; Chen, Jin-Hua; E, Zhan-Sen; Yang, Guang-Fu

    2004-01-01

    AIM: CT virtual endoscopy has been used in the study of various organs of body including the biliary tract, however, CT virtual endoseopy in diagnosis of gallbladder polyps has not yet been reported. This study was to evaluate the diagnostic value of CT virtual endoscopy in polyps of the gallbladder. METHODS: Thirty-two cases of gallbladder polyps were examined by CT virtual endoscopy, ultrasound, CT scan with oral biliary contrast separately and confirmed by operation and pathology. CT biliary cystoscopic findings were analyzed and compared with those of ultrasound and CT scan with oral biliary contrast, and evaluated in comparison with operative and pathologic findings in all cases. RESULTS: The detection rate of gallbladder polyps was 93.8%(90/96), 96.9%(93/96) and 79.2%(76/96) for CT cystoscopy, ultrasound and CT scan with oral contrast, respectively. CT biliary cystoscopy corresponded well with ultrasound as well as pathology in demonstrating the location, size and configuration of polyps. CT endoscopy was superior to ultrasound in viewing the polyps in a more precise way, 3 dimensionally from any angle in space, and showing the surface in details. CT biliary cystoscopy was also superior to CT scan with oral biliary contrast in terms of observation of the base of polyps for the presence of a pedicle, detection rates as well as image quality. The smallest polyp detected by CT biliary cystoscopy was measured 1.5 mm×2.2 mm×2.5 mm. CONCLUSION: CT biliary cystoscopy is a non-invasive and accurate technique for diagnosis and management of gallbladder polyps. PMID:15069726

  16. FDG-PET/CT and FLT-PET/CT for differentiating between lipid-poor benign and malignant adrenal tumours.

    PubMed

    Nakajo, Masatoyo; Jinguji, Megumi; Fukukura, Yoshihiko; Kajiya, Yoriko; Tani, Atushi; Nakajo, Masayuki; Nakabeppu, Yoshiaki; Arimura, Hiroshi; Nishio, Yoshihiko; Nakamura, Fumihiko; Yoshiura, Takashi

    2015-12-01

    To compare F-18-fluorodeoxyglucose (FDG) and F-18-fluorothymidine (FLT) PET/CT examinations for differentiating between benign and malignant adrenal tumours. Thirty lipid-poor benign and 11 malignant tumours of 40 patients were included. FDG- and FLT-based indices including visual score, maximum standardized uptake value (SUVmax) and FDG adrenal lesion/liver SUVmax (A/L SUVmax) or FLT adrenal lesion/back muscle SUVmax (A/B SUVmax) ratio were compared between benign and malignant tumours using the Mann-Whitney's U or Wilcoxon signed-rank test, and their diagnostic performances were evaluated by means of the area under the curve (AUC) values derived from the receiver operating characteristic analysis. All indices were significantly higher in malignant than benign tumours on both images (p < 0.05 each). On FDG-PET/CT, the sensitivity, specificity, and accuracy were 91 %, 63 % and 71 % for visual score, 91 %, 67 % and 73 % for SUVmax, and 100 %, 70 % and 78 % for A/L SUVmax ratio, respectively. On FLT-PET/CT, they were 100 %, 97 % and 98 % for visual score, SUVmax and A/B SUVmax ratio, respectively. All FLT indices were significantly higher than those of FDG in AUC (p < 0.05 each). FLT-PET/CT may be superior to FDG-PET/CT in differentiating lipid-poor benign from malignant adrenal tumours because of higher specificity and accuracy. • All FDG indices were significantly higher in malignant than in benign tumours. • All FLT indices were significantly higher in malignant than in benign tumours. • All FLT indices were significantly higher than those of FDG in AUC.

  17. The utility of two somatostatin analog radiopharmaceuticals in assessment of radiologically indeterminate pulmonary lesions.

    PubMed

    Sobic-Saranovic, Dragana P; Pavlovic, Smiljana V; Artiko, Vera M; Saranovic, Djordjije Z; Jaksic, Emilija D; Subotic, Dragan; Nagorni-Obradovic, Ljudmila; Kozarevic, Nebojsa; Petrovic, Nebojsa; Grozdic, Isidora T; Obradovic, Vladimir B

    2012-01-01

    The aim of our study was to assess diagnostic accuracy of Tc-99m depreotide and Tc-99m-EDDA/HYNIC-TOC scintigraphy for evaluation of pulmonary lesions that appeared ambiguous on computed tomography (CT). Forty-nine consecutive patients (37 men and 12 women; mean age, 60 ± 11 years) with 60 pulmonary lesions on chest radiography and CT were referred for nuclear imaging. They were prospectively allocated to undergo whole-body scintigraphy (WBS) and single photon emission computed tomography (SPECT) using either Tc-99m depreotide (26 patients, group 1) or Tc-99m-EDDA/HYNIC-TOC imaging (23 patients, group 2). Histologic findings after tissue biopsy served as a gold standard for determining diagnostic accuracy of the 2 somatostatin analogs. Visual assessment was complemented by semiquantitative analysis based on target to background ratio. Among the 32 pulmonary lesions scanned with Tc-99m depreotide, focal uptake was increased in 22 of 25 malignancies, whereas no uptake was found in 6 of 7 benign lesions (88% sensitivity, 85% specificity, and 88% accuracy) on both WBS and SPECT. Imaging of 28 pulmonary lesions with Tc-99m-EDDA/HYNIC-TOC had a similar diagnostic yield (sensitivity 87%, specificity 84%, and accuracy 86%). Overall, target to background ratios were higher on SPECT than WBS but not significantly different between groups 1 and 2 (SPECT 2.72 ± 0.70 vs. 2.71 ± 0.50, WBS 1.61 ± 0.32 vs. 1.62 ± 0.28, respectively). This study demonstrates that Tc-99m depreotide and Tc-99m-EDDA/HYNIC-TOC have similar diagnostic value for characterizing pulmonary lesions that appear ambiguous on CT.

  18. Effectiveness of Breast MRI and (18)F-FDG PET/CT for the Preoperative Staging of Invasive Lobular Carcinoma versus Ductal Carcinoma.

    PubMed

    Jung, Na Young; Kim, Sung Hoon; Kim, Sung Hun; Seo, Ye Young; Oh, Jin Kyoung; Choi, Hyun Su; You, Won Jong

    2015-03-01

    We evaluated the utility of magnetic resonance imaging (MRI) and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) for the preoperative staging of invasive lobular carcinoma (ILC) of the breast and compared the results with those of invasive ductal carcinoma (IDC). The study included pathologically proven 32 ILCs and 73 IDCs. We compared clinical and histopathological characteristics and the diagnostic performances of MRI and (18)F-FDG PET/CT for the primary mass, additional ipsilateral and/or contralateral lesion(s), and axillary lymph node metastasis between the ILC and IDC groups. Primary ILCs were greater in size, but demonstrated lower maximum standardized uptake values than IDCs. All primary masses were detected on MRI. The detection rate for ILCs (75.0%) was lower than that for IDCs (83.6%) on (18)F-FDG PET/CT, but the difference was not significant. For additional ipsilateral lesion(s), the sensitivities and specificities of MRI were 87.5% and 58.3% for ILC and 100.0% and 66.7% for IDC, respectively; whereas the sensitivities and specificities of (18)F-FDG PET/CT were 0% and 91.7% for ILC and 37.5% and 94.7% for IDC, respectively. The sensitivity of (18)F-FDG PET/CT for ipsilateral lesion(s) was significantly lower in the ILC group than the IDC group. The sensitivity for ipsilateral lesion(s) was significantly higher with MRI; however, specificity was higher with (18)F-FDG PET/CT in both tumor groups. There was no significant difference in the diagnostic performance for additional contralateral lesion(s) or axillary lymph node metastasis on MRI or (18)F-FDG PET/CT for ILC versus IDC. The MRI and (18)F-FDG PET/CT detection rates for the primary cancer do not differ between the ILC and IDC groups. Although (18)F-FDG PET/CT demonstrates lower sensitivity for primary and additional ipsilateral lesions, it shows higher specificity for additional ipsilateral lesions, and could play a complementary role in the staging of ILC as well as IDC.

  19. Comparison of quantitatively analyzed dynamic area-detector CT using various mathematic methods with FDG PET/CT in management of solitary pulmonary nodules.

    PubMed

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2013-06-01

    The objective of our study was to prospectively compare the capability of dynamic area-detector CT analyzed with different mathematic methods and PET/CT in the management of pulmonary nodules. Fifty-two consecutive patients with 96 pulmonary nodules underwent dynamic area-detector CT, PET/CT, and microbacterial or pathologic examinations. All nodules were classified into the following groups: malignant nodules (n = 57), benign nodules with low biologic activity (n = 15), and benign nodules with high biologic activity (n = 24). On dynamic area-detector CT, the total, pulmonary arterial, and systemic arterial perfusions were calculated using the dual-input maximum slope method; perfusion was calculated using the single-input maximum slope method; and extraction fraction and blood volume (BV) were calculated using the Patlak plot method. All indexes were statistically compared among the three nodule groups. Then, receiver operating characteristic analyses were used to compare the diagnostic capabilities of the maximum standardized uptake value (SUVmax) and each perfusion parameter having a significant difference between malignant and benign nodules. Finally, the diagnostic performances of the indexes were compared by means of the McNemar test. No adverse effects were observed in this study. All indexes except extraction fraction and BV, both of which were calculated using the Patlak plot method, showed significant differences among the three groups (p < 0.05). Areas under the curve of total perfusion calculated using the dual-input method, pulmonary arterial perfusion calculated using the dual-input method, and perfusion calculated using the single-input method were significantly larger than that of SUVmax (p < 0.05). The accuracy of total perfusion (83.3%) was significantly greater than the accuracy of the other indexes: pulmonary arterial perfusion (72.9%, p < 0.05), systemic arterial perfusion calculated using the dual-input method (69.8%, p < 0.05), perfusion (66.7%, p < 0.05), and SUVmax (60.4%, p < 0.05). Dynamic area-detector CT analyzed using the dual-input maximum slope method has better potential for the diagnosis of pulmonary nodules than dynamic area-detector CT analyzed using other methods and than PET/CT.

  20. [Evaluation of upper cervical spine injury (C1-C2) with computed tomography].

    PubMed

    Siemianowicz, Anna; Baron, Jan; Wawrzynek, Wojciech; Koczy, Bogdan; Kasprowska, Sabina

    2006-01-01

    Cervical spine injuries are common and essential diagnostic problem. Diagnostic imaging is necessary for proper and effective treatment. Helical computed tomography (CT) and plain radiography are the basic diagnostic methods in cervical spine injuries. The purpose of this work was the comparison of CT examination of the upper cervical spine (CI-C2) with patients' clinical state. Twenty four patients (17 men and 7 women) were introduced into the study. The most common cause of cervical spine injuries were car accidents (48.5%). CT examination was performed in all patients. Six patients (25%) had multilevel injury, localized at C1-C2 level and in the lower part of cervical spine. The main pathology diagnosed by CT in the studied group was rotatory subluxation (66.6%). Eight patients (33.3%), with rotatory subluxation did not present any abnormalities in neurological examination performed immediately after the admission to the hospital. C1 and/or C2 fractures were diagnosed in 11 patients (45.8%), in some cases (in 3 patients - 12.5%) they were accompanied by rotatory subluxations. CT examination is the basic technique of diagnostic imaging in a case of cervical spine injuries. It enables quick, accurate and precise evaluation of bone structures and surrounding soft tissues. CT also enables multiplanar imaging and 3-dimentional imaging.

  1. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  2. Role of (18)F-FDG PET-CT in head and neck squamous cell carcinoma.

    PubMed

    Castaldi, P; Leccisotti, L; Bussu, F; Miccichè, F; Rufini, V

    2013-02-01

    The role of PET-CT imaging in head and neck squamous cell carcinoma during pre-treatment staging, radiotherapy planning, treatment response assessment and post-therapy follow-up is reviewed with focus on current evidence, controversial issues and future clinical applications. In staging, the role of (18)F-FDG PET-CT is well recognized for detecting cervical nodal involvement as well as for exclusion of distant metastases and synchronous primary tumours. In the evaluation of treatment response, the high negative predictive value of (18)F-FDG PET-CT performed at least 8 weeks from the end of radio-chemotherapy allows prevention of unnecessary diagnostic invasive procedures and neck dissection in many patients, with a significant impact on clinical outcome. On the other hand, in this setting, the low positive predictive value due to possible post-radiation inflammation findings requires special care before making a clinical decision. Controversial data are currently available on the role of PET imaging during the course of radio-chemotherapy. The prognostic role of (18)F-FDG PET-CT imaging in head and neck squamous cell carcinoma is recently emerging, in addition to the utility of this technique in evaluation of the tumour volume for planning radiation therapy. Additionally, new PET radiopharmaceuticals could provide considerable information on specific tumour characteristics, thus overcoming the limitations of (18)F-FDG.

  3. SU-E-J-242: Volume-Dependence of Quantitative Imaging Features From CT and CE-CT Images of NSCLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fave, X; Fried, D; UT Health Science Center Graduate School of Biomedical Sciences, Houston, TX

    Purpose: To determine whether tumor volume plays a significant role in the values obtained for texture features when they are extracted from computed tomography (CT) images of non-small cell lung cancer (NSCLC). We also sought to identify whether features can be reliably measured at all volumes or if a minimum volume threshold should be recommended. Methods: Eleven features were measured on 40 CT and 32 contrast-enhanced CT (CECT) patient images for this study. Features were selected for their prognostic/diagnostic value in previous publications. Direct correlations between these textures and volume were evaluated using the Spearman correlation coefficient. Any texture thatmore » the Wilcoxon rank-sum test was used to compare the variation above and below a volume cutoff. Four different volume thresholds (5, 10, 15, and 20 cm{sup 3}) were tested. Results: Four textures were found to be significantly correlated with volume in both the CT and CE-CT images. These were busyness, coarseness, gray-level nonuniformity, and run-length nonuniformity with correlation coefficients of 0.92, −0.96, 0.94, and 0.98 for the CT images and 0.95, −0.97, 0.98, and 0.98 for the CE-CT images. After volume normalization, the correlation coefficients decreased substantially. For the data obtained from the CT images, the results of the Wilcoxon rank-sum test were significant when volume thresholds of 5–15 cm3 were used. No volume threshold was shown to be significant for the CE-CT data. Conclusion: Equations for four features that have been used in several published studies were found to be volume-dependent. Future studies should consider implementing normalization factors or removing these features entirely to prevent this potential source of redundancy or bias. This work was supported in part by National Cancer Institute grant R03CA178495-01. Xenia Fave is a recipient of the American Association of Physicists in Medicine Graduate Fellowship.« less

  4. The added value of 68Ga-DOTA-TATE-PET to contrast-enhanced CT for primary site detection in CUP of neuroendocrine origin.

    PubMed

    Kazmierczak, Philipp M; Rominger, Axel; Wenter, Vera; Spitzweg, Christine; Auernhammer, Christoph; Angele, Martin K; Rist, Carsten; Cyran, Clemens C

    2017-04-01

    To quantify the additional value of 68 Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced 68 Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and 68 Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up 68 Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p < 0.001). 68 Ga-DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. • 68 Ga-DOTA-TATE PET augments the sensitivity of contrast-enhanced CT by 50 % • 68 Ga-DOTA-TATE PET augments the accuracy of contrast-enhanced CT by 30 % • Somatostatin receptor-targeted hybrid imaging optimizes primary tumour detection in CUP-NET.

  5. Computed tomography arthrography using a radial plane view for the detection of triangular fibrocartilage complex foveal tears.

    PubMed

    Moritomo, Hisao; Arimitsu, Sayuri; Kubo, Nobuyuki; Masatomi, Takashi; Yukioka, Masao

    2015-02-01

    To classify triangular fibrocartilage complex (TFCC) foveal lesions on the basis of computed tomography (CT) arthrography using a radial plane view and to correlate the CT arthrography results with surgical findings. We also tested the interobserver and intra-observer reliability of the radial plane view. A total of 33 patients with a suspected TFCC foveal tear who had undergone wrist CT arthrography and subsequent surgical exploration were enrolled. We classified the configurations of TFCC foveal lesions into 5 types on the basis of CT arthrography with the radial plane view in which the image slices rotate clockwise centered on the ulnar styloid process. Sensitivity, specificity, and positive predictive values were calculated for each type of foveal lesion in CT arthrography to detect foveal tears. We determined interobserver and intra-observer agreements using kappa statistics. We also compared accuracies with the radial plane views with those with the coronal plane views. Among the tear types on CT arthrography, type 3, a roundish defect at the fovea, and type 4, a large defect at the overall ulnar insertion, had high specificity and positive predictive value for the detection of foveal tears. Specificity and positive predictive values were 90% and 89% for type 3 and 100% and 100% for type 4, respectively, whereas sensitivity was 35% for type 3 and 22% for type 4. Interobserver and intra-observer agreement was substantial and almost perfect, respectively. The radial plane view identified foveal lesion of each palmar and dorsal radioulnar ligament separately, but accuracy results with the radial plane views were not statistically different from those with the coronal plane views. Computed tomography arthrography with a radial plane view exhibited enhanced specificity and positive predictive value when a type 3 or 4 lesion was identified in the detection of a TFCC foveal tear compared with historical controls. Diagnostic II. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  6. Comparative Evaluation of the Diagnostic Performance of the Prototype Cepheid GeneXpert Ebola Assay

    PubMed Central

    Jansen van Vuren, Petrus; Grobbelaar, Antoinette; Storm, Nadia; Conteh, Ousman; Konneh, Kelfala; Kamara, Abdul; Sanne, Ian

    2015-01-01

    The Ebola virus disease (EVD) outbreak in West Africa has highlighted an urgent need for point-of-care (POC) assays for the diagnosis of this devastating disease in resource-limited African countries. The diagnostic performance characteristics of a prototype Cepheid GeneXpert Ebola POC used to detect Ebola virus (EBOV) in stored serum and plasma samples collected from suspected EVD cases in Sierra Leone in 2014 and 2015 was evaluated. The GeneXpert Ebola POC is a self-contained single-cartridge automated system that targets the glycoprotein (GP) and nucleoprotein (NP) genes of EBOV and yields results within 90 min. Results from 281 patient samples were compared to the results of a TaqMan real-time reverse transcription-PCR (RT-PCR) targeting the polymerase gene and performed on two real-time PCR machines. Agreement between the three platforms was 100% at cycle threshold (CT) values of ≤34.99, but discordant results were noted between CT values of 35 and 45.The diagnostic sensitivity of the three platforms was 100% in 91 patient samples that were confirmed to be infectious by virus isolation. All three molecular platforms detected viral EBOV RNA in additional samples that did not contain viable EBOV. The analytical sensitivity of the GeneXpert Ebola POC for the detection of NP was higher, and comparable to that of polymerase gene detection, than that for the detection of GP when using a titrated laboratory stock of EBOV. There was no detectable cross-reactivity with other hemorrhagic fever viruses or arboviruses. The GeneXpert Ebola POC offers an easy to operate and sensitive diagnostic tool that can be used for the rapid screening of suspected EVD cases in treatment or in holding centers during EVD outbreaks. PMID:26637383

  7. Advanced imaging systems for diagnostic investigations applied to Cultural Heritage

    NASA Astrophysics Data System (ADS)

    Peccenini, E.; Albertin, F.; Bettuzzi, M.; Brancaccio, R.; Casali, F.; Morigi, M. P.; Petrucci, F.

    2014-12-01

    The diagnostic investigations are an important resource in the studies on Cultural Heritage to enhance the knowledge on execution techniques, materials and conservation status of a work of art. In this field, due to the great historical and artistic value of the objects, preservation is the main concern; for this reason, new technological equipment has been designed and developed in the Physics Departments of the Universities of Ferrara and Bologna to enhance the non-invasive approach to the study of pictorial artworks and other objects of cultural interest. Infrared (IR) reflectography, X-ray radiography and computed tomography (CT), applied to works of art, are joined by the same goal: to get hidden information on execution techniques and inner structure pursuing the non-invasiveness of the methods, although using different setup and physical principles. In this work transportable imaging systems to investigate large objects in museums and galleries are presented. In particular, 2D scanning devices for IR reflectography and X-ray radiography, CT systems and some applications to the Cultural Heritage are described.

  8. Surgical treatment of secondary peritonitis : A continuing problem.

    PubMed

    van Ruler, O; Boermeester, M A

    2017-01-01

    Secondary peritonitis remains associated with high mortality and morbidity rates. Treatment of secondary peritonitis is challenging even in modern medicine. Surgical intervention for source control remains the cornerstone of treatment, beside adequate antimicrobial therapy and resuscitation. A randomized clinical trial showed that relaparotomy on demand (ROD) after initial emergency surgery is the preferred treatment strategy, irrespective of the severity and extent of peritonitis. The effective and safe use of ROD requires intensive monitoring of the patient in a setting where diagnostic tests and decision making about relaparotomy are guaranteed round the clock. The lack of knowledge on timely and adequate patient selection, together with the lack of use of easy but reliable monitoring tools, seems to hamper full implementation of ROD. The accuracy of the relap decision tool is reasonable for prediction of ongoing peritonitis and selection for computer tomography (CT). The value of CT in an early postoperative phase is unclear. Future research and innovative technologies should focus on the additive value of CT in cases of operated secondary peritonitis and on the further optimization of bedside prediction tools to enhance adequate patient selection for intervention in a multidisciplinary setting.

  9. Diagnosis of bowel infarction: a comparison of plain films and CT scans in 23 cases.

    PubMed

    Smerud, M J; Johnson, C D; Stephens, D H

    1990-01-01

    We retrospectively reviewed abdominal CT and plain film findings in 23 proved cases of mesenteric infarction to compare the value of the two techniques. Criteria considered specific for infarction on CT were identified in nine (39%) of 23 patients and comprised pneumatosis in seven patients (30%), mesenteric or portal venous gas in three patients (13%), and focally thick-walled bowel in two patients (9%). Criteria considered specific for bowel infarction on plain films were identified in seven (30%) of 23 patients and comprised focally edematous bowel in six patients (26%) and pneumatosis intestinalis in one patient (4%). Only one patient had specific changes on both CT and plain films, but 15 (65%) of the 23 showed specific changes on at least one study. The results indicate that plain films remain an important tool in patients suspected of mesenteric infarction and can provide information that is complementary to CT. Also, as both studies were nonspecific in eight (35%) of our patients, negative or nonspecific findings should not deter further diagnostic or interventional procedures in patients in whom the clinical suspicion of bowel infarction is high.

  10. Additional value of hybrid SPECT/CT systems in neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas.

    PubMed

    Wong, K K; Chondrogiannis, S; Fuster, D; Ruiz, C; Marzola, M C; Giammarile, F; Colletti, P M; Rubello, D

    The aim of this review was to evaluate the potential advantages of SPECT/CT hybrid imaging in the management of neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas. From the collected data, the superiority of fused images was observed as providing both functional/molecular and morphological imaging compared to planar imaging. This provided an improvement in diagnostic imaging, with significant advantages as regards: (1) precise locating of the lesions; (2) an improvement in characterization of the findings, resulting higher specificity, improved sensitivity, and overall greater accuracy, (3) additional anatomical information derived from the CT component; (4) CT-based attenuation correction and potential for volumetric dosimetry calculations, and (5) improvement on the impact on patient management (e.g. in better defining treatment plans, in shortening surgical operating times). It can be concluded that SPECT/CT hybrid imaging provides the nuclear medicine physician with a powerful imaging modality in comparison to planar imaging, providing essential information about the location of lesions, and high quality homogeneous images. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  11. 3D SPECT/CT fusion using image data projection of bone SPECT onto 3D volume-rendered CT images: feasibility and clinical impact in the diagnosis of bone metastasis.

    PubMed

    Ogata, Yuji; Nakahara, Tadaki; Ode, Kenichi; Matsusaka, Yohji; Katagiri, Mari; Iwabuchi, Yu; Itoh, Kazunari; Ichimura, Akira; Jinzaki, Masahiro

    2017-05-01

    We developed a method of image data projection of bone SPECT into 3D volume-rendered CT images for 3D SPECT/CT fusion. The aims of our study were to evaluate its feasibility and clinical usefulness. Whole-body bone scintigraphy (WB) and SPECT/CT scans were performed in 318 cancer patients using a dedicated SPECT/CT systems. Volume data of bone SPECT and CT were fused to obtain 2D SPECT/CT images. To generate our 3D SPECT/CT images, colored voxel data of bone SPECT were projected onto the corresponding location of the volume-rendered CT data after a semi-automatic bone extraction. Then, the resultant 3D images were blended with conventional volume-rendered CT images, allowing to grasp the three-dimensional relationship between bone metabolism and anatomy. WB and SPECT (WB + SPECT), 2D SPECT/CT fusion, and 3D SPECT/CT fusion were evaluated by two independent reviewers in the diagnosis of bone metastasis. The inter-observer variability and diagnostic accuracy in these three image sets were investigated using a four-point diagnostic scale. Increased bone metabolism was found in 744 metastatic sites and 1002 benign changes. On a per-lesion basis, inter-observer agreements in the diagnosis of bone metastasis were 0.72 for WB + SPECT, 0.90 for 2D SPECT/CT, and 0.89 for 3D SPECT/CT. Receiver operating characteristic analyses for the diagnostic accuracy of bone metastasis showed that WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT had an area under the curve of 0.800, 0.983, and 0.983 for reader 1, 0.865, 0.992, and 0.993 for reader 2, respectively (WB + SPECT vs. 2D or 3D SPECT/CT, p < 0.001; 2D vs. 3D SPECT/CT, n.s.). The durations of interpretation of WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT images were 241 ± 75, 225 ± 73, and 182 ± 71 s for reader 1 and 207 ± 72, 190 ± 73, and 179 ± 73 s for reader 2, respectively. As a result, it took shorter time to read 3D SPECT/CT images than 2D SPECT/CT (p < 0.0001) or WB + SPECT images (p < 0.0001). 3D SPECT/CT fusion offers comparable diagnostic accuracy to 2D SPECT/CT fusion. The visual effect of 3D SPECT/CT fusion facilitates reduction of reading time compared to 2D SPECT/CT fusion.

  12. Case Report: SPECT/CT as the New Diagnostic Tool for Specific Wrist Pathology.

    PubMed

    Linde, Musters; Ten Broek, M; Kraan, G A

    2017-01-01

    Single photon emission computed tomography has been introduced as a promising new diagnostic tool in orthopaedic pathology since the early 90'. Computed tomography, the combined with SPECT, gives insight in the specific sight of wrist pathology. Literature already supports introduction of SPECT/CT in wrist pathology, but clinical application is lagging. A 40yr old patient reported first in 2004 with persisting pain after a right distal radius fracture. Several diagnostics and operative interventions were performed, all unsuccessful. Because of the persisting pain a SPECT-CT was performed which showed a cyst in the hamate bone, which was successfully enucleated. The patient was finally pain free at recent follow-up. With a QDash-score of 43 and a PRW (H) E-DLV-score of 58/150. In this case report, SPECT/CT proved a very sensitive diagnostic tool for specific pathology of the wrist. It offered precise localisation and thereby the clinically suspected diagnosis was confirmed and the patient successfully treated.

  13. CT Scan-Guided Abrams' Needle Pleural Biopsy versus Ultrasound-Assisted Cutting Needle Pleural Biopsy for Diagnosis in Patients with Pleural Effusion: A Randomized, Controlled Trial.

    PubMed

    Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma

    2016-01-01

    Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.

  14. Computed tomography versus magnetic resonance imaging for diagnosing cervical lymph node metastasis of head and neck cancer: a systematic review and meta-analysis

    PubMed Central

    Sun, J; Li, B; Li, CJ; Li, Y; Su, F; Gao, QH; Wu, FL; Yu, T; Wu, L; Li, LJ

    2015-01-01

    Computed tomography (CT) and magnetic resonance imaging (MRI) are common imaging methods to detect cervical lymph node metastasis of head and neck cancer. We aimed to assess the diagnostic efficacy of CT and MRI in detecting cervical lymph node metastasis, and to establish unified diagnostic criteria via systematic review and meta-analysis. A systematic literature search in five databases until January 2014 was carried out. All retrieved studies were reviewed and eligible studies were qualitatively summarized. Besides pooling the sensitivity (SEN) and specificity (SPE) data of CT and MRI, summary receiver operating characteristic curves were generated. A total of 63 studies including 3,029 participants were involved. The pooled results of meta-analysis showed that CT had a higher SEN (0.77 [95% confidence interval {CI} 0.73–0.87]) than MRI (0.72 [95% CI 0.70–0.74]) when node was considered as unit of analysis (P<0.05); MRI had a higher SPE (0.81 [95% CI 0.80–0.82]) than CT (0.72 [95% CI 0.69–0.74]) when neck level was considered as unit of analysis (P<0.05) and MRI had a higher area under concentration-time curve than CT when the patient was considered as unit of analysis (P<0.05). With regards to diagnostic criteria, for MRI, the results showed that the minimal axial diameter of 10 mm could be considered as the best size criterion, compared to 12 mm for CT. Overall, MRI conferred significantly higher SPE while CT demonstrated higher SEN. The diagnostic criteria for MRI and CT on size of metastatic lymph nodes were suggested as 10 and 12 mm, respectively. PMID:26089682

  15. A new SPECT/CT reconstruction algorithm: reliability and accuracy in clinical routine for non-oncologic bone diseases.

    PubMed

    Delcroix, Olivier; Robin, Philippe; Gouillou, Maelenn; Le Duc-Pennec, Alexandra; Alavi, Zarrin; Le Roux, Pierre-Yves; Abgral, Ronan; Salaun, Pierre-Yves; Bourhis, David; Querellou, Solène

    2018-02-12

    xSPECT Bone® (xB) is a new reconstruction algorithm developed by Siemens® in bone hybrid imaging (SPECT/CT). A CT-based tissue segmentation is incorporated into SPECT reconstruction to provide SPECT images with bone anatomy appearance. The objectives of this study were to assess xB/CT reconstruction diagnostic reliability and accuracy in comparison with Flash 3D® (F3D)/CT in clinical routine. Two hundred thirteen consecutive patients referred to the Brest Nuclear Medicine Department for non-oncological bone diseases were evaluated retrospectively. Two hundred seven SPECT/CT were included. All SPECT/CT were independently interpreted by two nuclear medicine physicians (a junior and a senior expert) with xB/CT then with F3D/CT three months later. Inter-observer agreement (IOA) and diagnostic confidence were determined using McNemar test, and unweighted Kappa coefficient. The study objectives were then re-assessed for validation through > 18 months of clinical and paraclinical follow-up. No statistically significant differences between IOA xB and IOA F3D were found (p = 0.532). Agreement for xB after categorical classification of the diagnoses was high (κ xB = 0.89 [95% CI 0.84 -0.93]) but without statistically significant difference F3D (κ F3D = 0.90 [95% CI 0.86 - 0.94]). Thirty-one (14.9%) inter-reconstruction diagnostic discrepancies were observed of which 21 (10.1%) were classified as major. The follow-up confirmed the diagnosis of F3D in 10 cases, xB in 6 cases and was non-contributory in 5 cases. xB reconstruction algorithm was found reliable, providing high interobserver agreement and similar diagnostic confidence to F3D reconstruction in clinical routine.

  16. Diagnostic imaging in paraneoplastic autoimmune multiorgan syndrome: retrospective single site study and literature review of 225 patients.

    PubMed

    Lehman, Vance T; Barrick, Benjamin J; Pittelkow, Mark R; Peller, Patrick J; Camilleri, Michael J; Lehman, Julia S

    2015-04-01

    The utility of diagnostic imaging in paraneoplastic autoimmune multiorgan syndrome (PAMS) is unknown. We examined the role of diagnostic imaging in patients with PAMS evaluated at our tertiary referral center (at Mayo Clinic, Rochester, MN, USA) and in the English literature between January 1, 1996, and August 31, 2012. We included 17 patients from our institution and 208 patients from the literature review. Of these 225 patients, 113 (50.2%) were not known to have a malignancy diagnosis at the time of PAMS diagnosis. Of the 123 patients from our institution and from the literature reported to undergo imaging studies, conventional computed tomography (CT) was the predominant imaging modality (n = 110; 89.4%); 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT was also used, albeit infrequently (n = 12; 9.8%). When CT was included in imaging to identify or confirm the presence of a malignancy, imaging was successful in all patients who ultimately were diagnosed with an associated malignancy. At our institution, a relatively high percentage (n = 7; 41%) of patients had 18F-FDG PET/CT, which not only identified all tumors found on CT but also facilitated staging of lymphoma and guided biopsy procedures. Diagnostic imaging is frequently utilized in PAMS with unknown malignancy. Both conventional CT and 18F-FDG PET/CT are likely to detect the typical underlying neoplasms. Relative to conventional CT, 18F-FDG PET/CT may provide additional useful information regarding prognosis for the likely underlying malignancies, although there is a paucity of reports describing the use of this modality for this purpose. © 2014 The International Society of Dermatology.

  17. Initial observations of electronic medical record usage during CT and MRI interpretation: Frequency of use and impact on workflow.

    PubMed

    Lin, Abraham; Harris, Mitchell; Zalis, Michael

    2010-07-01

    Electronic medical record (EMR) systems permit integration of contextual nonimaging EMR data into examination interpretation; however, the extra effort required to search and review these nonradiologic data are not well characterized. We assessed the gross frequency and pattern of EMR usage in the interpretation of diagnostic CT and MRI examinations. We defined nonradiologic EMR data as laboratory data, nonimaging specialty report, clinical note, and administrative data not available on PACS. For abdominal, neuroradiologic, and musculoskeletal CT and MRI, we prospectively recorded the time required for image analysis (including prior imaging studies and their reports), nonradiologic EMR use, and initial report drafting by fellows and staff in randomized sessions. We assessed EMR use as a fraction of work activity and according to technique, subspecialty, inpatient status, and radiologist experience. We observed 372 CT and MRI interpretations by 33 radiologists. For CT, radiologists used the EMR in 34% of abdominal, 57% of neuroradiologic, and 38% of musculoskeletal interpretations. For MRI, EMR was used in 73% of abdominal, 56% of neuroradiologic, and 33% of musculoskeletal interpretations. For CT, EMR usage comprised 18%, 14%, and 18% of diagnostic effort (image analysis plus EMR use) for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively; for MRI, EMR usage comprised 21%, 16%, and 15% of diagnostic effort for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively. Frequency of EMR use was significantly greater for neuroradiology CT and abdominal MRI (p < 0.05, Fisher's test). EMR usage was not consistently related to inpatient status for CT or radiologist experience. For CT and MRI interpretation, EMR usage is frequent and comprises a significant fraction of diagnostic effort.

  18. Unusual Radiographic Presentation of Pneumocystis Pneumonia in a Patient with AIDS.

    PubMed

    Block, Brian L; Mehta, Tejas; Ortiz, Gabriel M; Ferris, Sean P; Vu, Thienkhai H; Huang, Laurence; Cattamanchi, Adithya

    2017-01-01

    Pneumocystis jirovecii pneumonia (PCP) typically presents as an interstitial and alveolar process with ground glass opacities on chest computed tomography (CT). The absence of ground glass opacities on chest CT is thought to have a high negative predictive value for PCP in individuals with AIDS. Here, we report a case of PCP in a man with AIDS who presented to our hospital with subacute shortness of breath and a nonproductive cough. While his chest CT revealed diffuse nodular rather than ground glass opacities, bronchoscopy with bronchoalveolar lavage and transbronchial biopsies confirmed the diagnosis of PCP and did not identify additional pathogens. PCP was not the expected diagnosis based on chest CT, but it otherwise fit well with the patient's clinical and laboratory presentation. In the era of combination antiretroviral therapy, routine prophylaxis for PCP, and increased use of computed tomography, it may be that PCP will increasingly present with nonclassical chest radiographic patterns. Clinicians should be aware of this presentation when selecting diagnostic and management strategies.

  19. Unusual Radiographic Presentation of Pneumocystis Pneumonia in a Patient with AIDS

    PubMed Central

    Mehta, Tejas; Ortiz, Gabriel M.; Ferris, Sean P.; Vu, Thienkhai H.; Huang, Laurence; Cattamanchi, Adithya

    2017-01-01

    Pneumocystis jirovecii pneumonia (PCP) typically presents as an interstitial and alveolar process with ground glass opacities on chest computed tomography (CT). The absence of ground glass opacities on chest CT is thought to have a high negative predictive value for PCP in individuals with AIDS. Here, we report a case of PCP in a man with AIDS who presented to our hospital with subacute shortness of breath and a nonproductive cough. While his chest CT revealed diffuse nodular rather than ground glass opacities, bronchoscopy with bronchoalveolar lavage and transbronchial biopsies confirmed the diagnosis of PCP and did not identify additional pathogens. PCP was not the expected diagnosis based on chest CT, but it otherwise fit well with the patient's clinical and laboratory presentation. In the era of combination antiretroviral therapy, routine prophylaxis for PCP, and increased use of computed tomography, it may be that PCP will increasingly present with nonclassical chest radiographic patterns. Clinicians should be aware of this presentation when selecting diagnostic and management strategies. PMID:29362681

  20. Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets.

    PubMed

    Meenan, Christopher; Daly, Barry; Toland, Christopher; Nagy, Paul

    2006-01-01

    Rapid advances are changing the technology and applications of multidetector computed tomography (CT) scanners. The major increase in data associated with this new technology, however, breaks most commercial picture archiving and communication system (PACS) architectures by preventing them from delivering data in real time to radiologists and outside clinicians. We proposed a phased model for 3D workflow, installed a thin-slice archive and measured thin-slice data storage over a period of 5 months. A mean of 1,869 CT studies were stored per month, with an average of 643 images per study and a mean total volume of 588 GB/month. We also surveyed 48 radiologists to determine diagnostic use, impressions of thin-slice value, and requirements for retention times. The majority of radiologists thought thin slice was helpful for diagnosis and regularly used the application. Permanent storage of thin slice CT is likely to become best practice and a mission-critical pursuit for the health care enterprise.

  1. Feasibility and diagnostic performance of dual-tracer-guided sentinel lymph node biopsy in cT1-2N0M0 gastric cancer: a systematic review and meta-analysis of diagnostic studies.

    PubMed

    Huang, Ling; Wei, Tao; Chen, Junjun; Zhou, Donghui

    2017-05-16

    Dual-tracer-guided sentinel lymph node (SLN) biopsy may provide a promising diagnostic tool to assess accurately the status of lymph node metastasis in the surgical operation and assure the oncologic safety of the function or stomach preserving surgery. The diagnostic performance of this technology in recent studies varied. Thus, we conducted this meta-analysis. This systematic review and meta-analysis was registered at the PROSPERO. Eligible studies were searched in the PubMed, EMBASE, Web of Knowledge, and Cochrane Library databases. A random-effect model was used to pool the data. Summary receiver operator characteristic curves, analysis for publication bias, meta-regression, and subgroup analysis were also performed. The pooled SLN identification rate and sensitivity were 0.97 and 0.89. 99m Tc-human serum albumin with indocyanine green (ICG), 99m Tc-antimony sulfur colloid with ICG, performing SLN biopsy ≥15 min after dye injection, an SLN ≥5, the basin dissection, laparoscopic surgery, in studies conducted in Japan and studies published after 2012, were associated with higher sensitivity. CT1 stage, performing SLN biopsy ≥15 min after dye injection, in studies conducted in Japan and studies published after 2012, were related with a higher identification rate. Dual tracer is promising in SLN biopsy in gastric cancer, and the clinical application of SLN biopsy should be limited to the patients of cT1N0M0 gastric cancer. The combination of 99m Tc-human serum albumin and ICG as well as the combination of 99m Tc-antimony sulfur colloid and ICG may be the optimal tracer combination. However, it seems not justified to put this technique into routine clinical application recently. Some factors that might enhance diagnostic value are identified.

  2. Use of a primary care database to determine trends in genital chlamydia testing, diagnostic episodes and management in UK general practice, 1990–2004

    PubMed Central

    Hughes, Gwenda; Williams, Tim; Simms, Ian; Mercer, Catherine; Fenton, Kevin; Cassell, Jackie

    2007-01-01

    Objective To determine the extent of testing, diagnostic episodes and management of genital Chlamydia trachomatis (CT) infection in UK primary care using a large primary care database. Methods The incidence of CT tests, diagnostic episodes, treatments and referrals was measured for all adult patients in the General Practice Research Database between 1990 and 2004. Results Rates of CT testing in those aged 12–64 years in 2004 increased to 1439/100 000 patient years (py) in women but only 74/100 000 py in men. Testing rates were highest among 20–24‐year‐old women (5.5% tested in 2004), followed by 25–34‐year‐old women (3.7% tested in 2004). 0.5% of registered 16–24‐year‐old women were diagnosed as having CT infection in 2004. Three‐quarters of patients with a recorded diagnosis of CT had had an appropriate prescription issued in 2004, a proportion that increased from 1990 along with a decrease in referrals to genitourinary medicine. In 2004, general practitioners treated 25.0% of all recorded diagnoses of CT in women and 5.1% of those in men. Conclusions Testing for and diagnostic episodes of CT in primary care have increased since 1990. Testing continues disproportionately to target women aged >24 years. Extremely low rates of testing in men, together with high positivity, demonstrate a missed opportunity for diagnosis of CT and contact tracing in general practice. PMID:17360731

  3. Systematic Review and Meta-Analysis of CT Features for Differentiating Complicated and Uncomplicated Appendicitis.

    PubMed

    Kim, Hae Young; Park, Ji Hoon; Lee, Yoon Jin; Lee, Sung Soo; Jeon, Jong-June; Lee, Kyoung Ho

    2018-04-01

    Purpose To perform a systematic review and meta-analysis to identify computed tomographic (CT) features for differentiating complicated appendicitis in patients suspected of having appendicitis and to summarize their diagnostic accuracy. Materials and Methods Studies on diagnostic accuracy of CT features for differentiating complicated appendicitis (perforated or gangrenous appendicitis) in patients suspected of having appendicitis were searched in Ovid-MEDLINE, EMBASE, and the Cochrane Library. Overlapping descriptors used in different studies to denote the same image finding were subsumed under a single CT feature. Pooled diagnostic accuracy of the CT features was calculated by using a bivariate random effects model. CT features with pooled diagnostic odds ratios with 95% confidence intervals not including 1 were considered as informative. Results Twenty-three studies were included, and 184 overlapping descriptors for various CT findings were subsumed under 14 features. Of these, 10 features were informative for complicated appendicitis. There was a general tendency for these features to show relatively high specificity but low sensitivity. Extraluminal appendicolith, abscess, appendiceal wall enhancement defect, extraluminal air, ileus, periappendiceal fluid collection, ascites, intraluminal air, and intraluminal appendicolith showed pooled specificity greater than 70% (range, 74%-100%), but sensitivity was limited (range, 14%-59%). Periappendiceal fat stranding was the only feature that showed high sensitivity (94%; 95% confidence interval: 86%, 98%) but low specificity (40%; 95% confidence interval, 23%, 60%). Conclusion Ten informative CT features for differentiating complicated appendicitis were identified in this study, nine of which showed high specificity, but low sensitivity. © RSNA, 2017 Online supplemental material is available for this article.

  4. Evaluation of novel computerized tomography scoring systems in human traumatic brain injury: An observational, multicenter study

    PubMed Central

    Kivisaari, Riku; Svensson, Mikael; Skrifvars, Markus B.

    2017-01-01

    Background Traumatic brain injury (TBI) is a major contributor to morbidity and mortality. Computerized tomography (CT) scanning of the brain is essential for diagnostic screening of intracranial injuries in need of neurosurgical intervention, but may also provide information concerning patient prognosis and enable baseline risk stratification in clinical trials. Novel CT scoring systems have been developed to improve current prognostic models, including the Stockholm and Helsinki CT scores, but so far have not been extensively validated. The primary aim of this study was to evaluate the Stockholm and Helsinki CT scores for predicting functional outcome, in comparison with the Rotterdam CT score and Marshall CT classification. The secondary aims were to assess which individual components of the CT scores best predict outcome and what additional prognostic value the CT scoring systems contribute to a clinical prognostic model. Methods and findings TBI patients requiring neuro-intensive care and not included in the initial creation of the Stockholm and Helsinki CT scoring systems were retrospectively included from prospectively collected data at the Karolinska University Hospital (n = 720 from 1 January 2005 to 31 December 2014) and Helsinki University Hospital (n = 395 from 1 January 2013 to 31 December 2014), totaling 1,115 patients. The Marshall CT classification and the Rotterdam, Stockholm, and Helsinki CT scores were assessed using the admission CT scans. Known outcome predictors at admission were acquired (age, pupil responsiveness, admission Glasgow Coma Scale, glucose level, and hemoglobin level) and used in univariate, and multivariable, regression models to predict long-term functional outcome (dichotomizations of the Glasgow Outcome Scale [GOS]). In total, 478 patients (43%) had an unfavorable outcome (GOS 1–3). In the combined cohort, overall prognostic performance was more accurate for the Stockholm CT score (Nagelkerke’s pseudo-R2 range 0.24–0.28) and the Helsinki CT score (0.18–0.22) than for the Rotterdam CT score (0.13–0.15) and Marshall CT classification (0.03–0.05). Moreover, the Stockholm and Helsinki CT scores added the most independent prognostic value in the presence of other known clinical outcome predictors in TBI (6% and 4%, respectively). The aggregate traumatic subarachnoid hemorrhage (tSAH) component of the Stockholm CT score was the strongest predictor of unfavorable outcome. The main limitations were the retrospective nature of the study, missing patient information, and the varying follow-up time between the centers. Conclusions The Stockholm and Helsinki CT scores provide more information on the damage sustained, and give a more accurate outcome prediction, than earlier classification systems. The strong independent predictive value of tSAH may reflect an underrated component of TBI pathophysiology. A change to these newer CT scoring systems may be warranted. PMID:28771476

  5. Professional efficiencies for diagnostic imaging services rendered by different physicians: analysis of recent medicare multiple procedure payment reduction policy.

    PubMed

    Duszak, Richard; Silva, Ezequiel; Kim, Angela J; Barr, Robert M; Donovan, William D; Kassing, Pamela; McGinty, Geraldine; Allen, Bibb

    2013-09-01

    The aim of this study was to quantify potential physician work efficiencies and appropriate multiple procedure payment reductions for different same-session diagnostic imaging studies interpreted by different physicians in the same group practice. Medicare Resource-Based Relative Value Scale data were analyzed to determine the relative contributions of various preservice, intraservice, and postservice physician diagnostic imaging work activities. An expert panel quantified potential duplications in professional work activities when separate examinations were performed during the same session by different physicians within the same group practice. Maximum potential work duplications for various imaging modalities were calculated and compared with those used as the basis of CMS payment policy. No potential intraservice work duplication was identified when different examination interpretations were rendered by different physicians in the same group practice. When multiple interpretations within the same modality were rendered by different physicians, maximum potential duplicated preservice and postservice activities ranged from 5% (radiography, fluoroscopy, and nuclear medicine) to 13.6% (CT). Maximum mean potential duplicated work relative value units ranged from 0.0049 (radiography and fluoroscopy) to 0.0413 (CT). This equates to overall potential total work reductions ranging from 1.39% (nuclear medicine) to 2.73% (CT). Across all modalities, this corresponds to maximum Medicare professional component physician fee reductions of 1.23 ± 0.38% (range, 0.95%-1.87%) for services within the same modality, much less than an order of magnitude smaller than those implemented by CMS. For services from different modalities, potential duplications were too small to quantify. Although potential efficiencies exist in physician preservice and postservice work when same-session, same-modality imaging services are rendered by different physicians in the same group practice, these are relatively minuscule and have been grossly overestimated by current CMS payment policy. Greater transparency and methodologic rigor in government payment policy development are warranted. Copyright © 2013 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. Role of fluorine-18 fluorodeoxyglucose PET/CT in head and neck oncology: the point of view of the radiation oncologist

    PubMed Central

    Navarro, Arturo; del Hoyo, Olga; Gomez-Iturriaga, Alfonso; Alongi, Filippo; Medina, Jose A; Elicin, Olgun; Skanjeti, Andrea; Giammarile, Francesco; Bilbao, Pedro; Casquero, Francisco; de Bari, Berardino; Dal Pra, Alan

    2016-01-01

    Squamous cell carcinoma is the most common malignant tumour of the head and neck. The initial TNM staging, the evaluation of the tumour response during treatment, and the long-term surveillance are crucial moments in the approach to head and neck squamous cell carcinoma (HNSCC). Thus, at each of these moments, the choice of the best diagnostic tool providing the more precise and larger information is crucial. Positron emission tomography with fluorine-18 fludeoxyglucose integrated with CT (18F-FDG-PET/CT) rapidly gained clinical acceptance, and it has become an important imaging tool in routine clinical oncology. However, controversial data are currently available, for example, on the role of 18F-FDG-PET/CT imaging during radiotherapy planning, the prognostic value or its real clinical impact on treatment decisions. In this article, the role of 18F-FDG-PET/CT imaging in HNSCC during pre-treatment staging, radiotherapy planning, treatment response assessment, prognosis and follow-up is reviewed focusing on current evidence and controversial issues. A proposal on how to integrate 18F-FDG-PET/CT in daily clinical practice is also described. PMID:27416996

  7. Relationship of brain imaging with radionuclides and with x-ray computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhl, D.E.

    1981-03-03

    Because of high sensitivity and specificity for altered local cerebral structure, x-ray computed tomography (CT) is the preferred initial diagnostic imaging study under most circumstances when cerebral disease is suspected. CT has no competitor for detecting fresh intracerebral hemorrhage. Radionuclide imaging (RN) scan is preferred when relative perfusion is to be assessed, in patients allergic to contrast media, and when an adequate CT study is not technically possible. (RN) plays an important complementary role to CT, especially for patients suspected of subacute or chronic subdura hematoma, cerebral infarction, arteriovenous malformations, meningitis, encephalitis, normal pressure hydrocephalus, or when CT findings aremore » inconclusive. When CT is not available, RN serves as a good screening study for suspected cerebral tumor, infection, recent infarction, arteriovenous malformation, and chronic subdural hematoma. Future improvement in radionuclide imaging by means of emission composition potential. The compound plating approacl threshold for all the investigated transistors and fast neutron spectra lies within the raal. The value of the potential slightly changes with the coordinate change in this region, i.e. the charge on a collecting electrode is not practically guided up to a certain moment of time during the movement of nonequilibrium carriers.« less

  8. Differential diagnosis between benign and malignant pleural effusion with dual-energy spectral CT

    PubMed Central

    Zhang, Xirong; Duan, Haifeng; Yu, Yong; Ma, Chunling; Ren, Zhanli; Lei, Yuxin

    2018-01-01

    Purpose To investigate the value of spectral CT in the differential diagnosis of benign from malignant pleural effusion. Method and materials 14 patients with benign pleural effusion and 15 patients with malignant pleural effusion underwent non-contrast spectral CT imaging. These patients were later verified by the combination of disease history, clinical signs and other information with the consensus of surgeons and radiologists. Various Spectral CT image parameters measured for the effusion were as follows: CT numbers of the polychromatic 140kVp images, monochromatic images at 40keV and 100keV, the material density contents from the water, fat and blood-based material decomposition images, the effective atomic number and the spectral curve slope. These values were statistically compared with t test and logistic regression analysis between benign and malignant pleural effusion. Results The CT value of benign and malignant pleural effusion in the polychromatic 140kVp images showed no differences (12.61±3.39HU vs. 14.71±5.03HU) (P>0.05), however, they were statistically different on the monochromatic images at 40keV (43.15±3.79 vs. 39.42±2.60, p = 0.005) and 100keV (9.11±1.38 vs. 6.52±2.04, p<0.001). There was difference in the effective atomic number value between the benign (7.87±0.08) and malignant pleural effusion (7.90±0.02) (P = 0.02). Using 6.32HU as the threshold for CT value measurement at 100keV, one could obtain sensitivity of 100% and specificity of 66.7% with area-under-curve of 0.843 for differentiating benign from malignant effusion. In addition, age and disease history were potential confounding factors for differentiating malignant pleural effusion from benign, since the older age (61.13±12.51 year-old vs48.57±12.33 year-old) as well as longer disease history (70.00±49.28 day vs.28.36±21.64 day) were more easily to be found in the malignant pleural effusion group than those in the benign pleural effusion group. By combining above five factors, one could obtain sensitivity of 100% and specificity of 71.4% with area-under-curve of 0.933 for differentiating benign from malignant effusion. Conclusion The CT value measurement at both high and low energy levels and the effective atomic number obtained in a single spectral CT scan can assist the differential diagnosis of benign from malignant pleural effusion.Combining them with patient age and disease history can further improve diagnostic performance. Clinical relevance/Application Clinical findings and Spectral CT imaging can provide significant evidences about the nature of pleural effusion. PMID:29641601

  9. Differential diagnosis between benign and malignant pleural effusion with dual-energy spectral CT.

    PubMed

    Zhang, Xirong; Duan, Haifeng; Yu, Yong; Ma, Chunling; Ren, Zhanli; Lei, Yuxin; He, Taiping; Zhang, Ming

    2018-01-01

    To investigate the value of spectral CT in the differential diagnosis of benign from malignant pleural effusion. 14 patients with benign pleural effusion and 15 patients with malignant pleural effusion underwent non-contrast spectral CT imaging. These patients were later verified by the combination of disease history, clinical signs and other information with the consensus of surgeons and radiologists. Various Spectral CT image parameters measured for the effusion were as follows: CT numbers of the polychromatic 140kVp images, monochromatic images at 40keV and 100keV, the material density contents from the water, fat and blood-based material decomposition images, the effective atomic number and the spectral curve slope. These values were statistically compared with t test and logistic regression analysis between benign and malignant pleural effusion. The CT value of benign and malignant pleural effusion in the polychromatic 140kVp images showed no differences (12.61±3.39HU vs. 14.71±5.03HU) (P>0.05), however, they were statistically different on the monochromatic images at 40keV (43.15±3.79 vs. 39.42±2.60, p = 0.005) and 100keV (9.11±1.38 vs. 6.52±2.04, p<0.001). There was difference in the effective atomic number value between the benign (7.87±0.08) and malignant pleural effusion (7.90±0.02) (P = 0.02). Using 6.32HU as the threshold for CT value measurement at 100keV, one could obtain sensitivity of 100% and specificity of 66.7% with area-under-curve of 0.843 for differentiating benign from malignant effusion. In addition, age and disease history were potential confounding factors for differentiating malignant pleural effusion from benign, since the older age (61.13±12.51 year-old vs48.57±12.33 year-old) as well as longer disease history (70.00±49.28 day vs.28.36±21.64 day) were more easily to be found in the malignant pleural effusion group than those in the benign pleural effusion group. By combining above five factors, one could obtain sensitivity of 100% and specificity of 71.4% with area-under-curve of 0.933 for differentiating benign from malignant effusion. The CT value measurement at both high and low energy levels and the effective atomic number obtained in a single spectral CT scan can assist the differential diagnosis of benign from malignant pleural effusion.Combining them with patient age and disease history can further improve diagnostic performance. Clinical findings and Spectral CT imaging can provide significant evidences about the nature of pleural effusion.

  10. Assessment of glucose metabolism and cellular proliferation in multiple myeloma: a first report on combined 18F-FDG and 18F-FLT PET/CT imaging.

    PubMed

    Sachpekidis, C; Goldschmidt, H; Kopka, K; Kopp-Schneider, A; Dimitrakopoulou-Strauss, A

    2018-04-10

    Despite the significant upgrading in recent years of the role of 18 F-FDG PET/CT in multiple myeloma (MM) diagnostics, there is a still unmet need for myeloma-specific radiotracers. 3'-Deoxy-3'-[ 18 F]fluorothymidine ( 18 F-FLT) is the most studied cellular proliferation PET agent, considered a potentially new myeloma functional imaging tracer. The aim of this pilot study was to evaluate 18 F-FLT PET/CT in imaging of MM patients, in the context of its combined use with 18 F-FDG PET/CT. Eight patients, four suffering from symptomatic MM and four suffering from smoldering MM (SMM), were enrolled in the study. All patients underwent 18 F-FDG PET/CT and 18 F-FLT PET/CT imaging by means of static (whole body) and dynamic PET/CT of the lower abdomen and pelvis (dPET/CT) in two consecutive days. The evaluation of PET/CT studies was based on qualitative evaluation, semi-quantitative (SUV) calculation, and quantitative analysis based on two-tissue compartment modeling. 18 F-FDG PET/CT demonstrated focal, 18 F-FDG avid, MM-indicative bone marrow lesions in five patients. In contrary, 18 F-FLT PET/CT showed focal, 18 F-FLT avid, myeloma-indicative lesions in only two patients. In total, 48 18 F-FDG avid, focal, MM-indicative lesions were detected with 18 F-FDG PET/CT, while 17 18 F-FLT avid, focal, MM-indicative lesions were detected with 18 F-FLT PET/CT. The number of myeloma-indicative lesions was significantly higher for 18 F-FDG PET/CT than for 18 F-FLT PET/CT. A common finding was a mismatch of focally increased 18 F-FDG uptake and reduced 18 F-FLT uptake (lower than the surrounding bone marrow). Moreover, 18 F-FLT PET/CT was characterized by high background activity in the bone marrow compartment, further complicating the evaluation of bone marrow lesions. Semi-quantitative evaluation revealed that both SUV mean and SUV max were significantly higher for 18 F-FLT than for 18 F-FDG in both MM lesions and reference tissue. SUV values were higher in MM lesions than in reference bone marrow for both tracers. Despite the limited number of patients analyzed in this pilot study, the first results of the trial indicate that 18 F-FLT does not seem suitable as a single tracer in MM diagnostics. Further studies with a larger patient population are warranted to generalize the herein presented results.

  11. A whole-heart motion-correction algorithm: Effects on CT image quality and diagnostic accuracy of mechanical valve prosthesis abnormalities.

    PubMed

    Suh, Young Joo; Kim, Young Jin; Kim, Jin Young; Chang, Suyon; Im, Dong Jin; Hong, Yoo Jin; Choi, Byoung Wook

    2017-11-01

    We aimed to determine the effect of a whole-heart motion-correction algorithm (new-generation snapshot freeze, NG SSF) on the image quality of cardiac computed tomography (CT) images in patients with mechanical valve prostheses compared to standard images without motion correction and to compare the diagnostic accuracy of NG SSF and standard CT image sets for the detection of prosthetic valve abnormalities. A total of 20 patients with 32 mechanical valves who underwent wide-coverage detector cardiac CT with single-heartbeat acquisition were included. The CT image quality for subvalvular (below the prosthesis) and valvular regions (valve leaflets) of mechanical valves was assessed by two observers on a four-point scale (1 = poor, 2 = fair, 3 = good, and 4 = excellent). Paired t-tests or Wilcoxon signed rank tests were used to compare image quality scores and the number of diagnostic phases (image quality score≥3) between the standard image sets and NG SSF image sets. Diagnostic performance for detection of prosthetic valve abnormalities was compared between two image sets with the final diagnosis set by re-operation or clinical findings as the standard reference. NG SSF image sets had better image quality scores than standard image sets for both valvular and subvalvular regions (P < 0.05 for both). The number of phases that were of diagnostic image quality per patient was significantly greater in the NG SSF image set than standard image set for both valvular and subvalvular regions (P < 0.0001). Diagnostic performance of NG SSF image sets for the detection of prosthetic abnormalities (20 pannus and two paravalvular leaks) was greater than that of standard image sets (P < 0.05). Application of NG SSF can improve CT image quality and diagnostic accuracy in patients with mechanical valves compared to standard images. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  12. Coronary Artery Disease: Analysis of Diagnostic Performance of CT Perfusion and MR Perfusion Imaging in Comparison with Quantitative Coronary Angiography and SPECT-Multicenter Prospective Trial.

    PubMed

    Rief, Matthias; Chen, Marcus Y; Vavere, Andrea L; Kendziora, Benjamin; Miller, Julie M; Bandettini, W Patricia; Cox, Christopher; George, Richard T; Lima, João; Di Carli, Marcelo; Plotkin, Michail; Zimmermann, Elke; Laule, Michael; Schlattmann, Peter; Arai, Andrew E; Dewey, Marc

    2018-02-01

    Purpose To compare the diagnostic performance of stress myocardial computed tomography (CT) perfusion with that of stress myocardial magnetic resonance (MR) perfusion imaging in the detection of coronary artery disease (CAD). Materials and Methods All patients gave written informed consent prior to inclusion in this institutional review board-approved study. This two-center substudy of the prospective Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-Detector Row Computed Tomography (CORE320) multicenter trial included 92 patients (mean age, 63.1 years ± 8.1 [standard deviation]; 73% male). All patients underwent perfusion CT and perfusion MR imaging with either adenosine or regadenoson stress. The predefined reference standards were combined quantitative coronary angiography (QCA) and single-photon emission CT (SPECT) or QCA alone. Results from coronary CT angiography were not included, and diagnostic performance was evaluated with the Mantel-Haenszel test stratified by disease status. Results The prevalence of CAD was 39% (36 of 92) according to QCA and SPECT and 64% (59 of 92) according to QCA alone. When compared with QCA and SPECT, per-patient diagnostic accuracy of perfusion CT and perfusion MR imaging was 63% (58 of 92) and 75% (69 of 92), respectively (P = .11); sensitivity was 92% (33 of 36) and 83% (30 of 36), respectively (P = .45); and specificity was 45% (25 of 56) and 70% (39 of 56), respectively (P < .01). When compared with QCA alone, diagnostic accuracy of CT perfusion and MR perfusion imaging was 82% (75 of 92) and 74% (68 of 92), respectively (P = .27); sensitivity was 90% (53 of 59) and 69% (41 of 59), respectively (P < .01); and specificity was 67% (22 of 33) and 82% (27 of 33), respectively (P = .27). Conclusion This multicenter study shows that the diagnostic performance of perfusion CT is similar to that of perfusion MR imaging in the detection of CAD. © RSNA, 2017 Online supplemental material is available for this article.

  13. Very low-dose (0.15 mGy) chest CT protocols using the COPDGene 2 test object and a third-generation dual-source CT scanner with corresponding third-generation iterative reconstruction software.

    PubMed

    Newell, John D; Fuld, Matthew K; Allmendinger, Thomas; Sieren, Jered P; Chan, Kung-Sik; Guo, Junfeng; Hoffman, Eric A

    2015-01-01

    The purpose of this study was to evaluate the impact of ultralow radiation dose single-energy computed tomographic (CT) acquisitions with Sn prefiltration and third-generation iterative reconstruction on density-based quantitative measures of growing interest in phenotyping pulmonary disease. The effects of both decreasing dose and different body habitus on the accuracy of the mean CT attenuation measurements and the level of image noise (SD) were evaluated using the COPDGene 2 test object, containing 8 different materials of interest ranging from air to acrylic and including various density foams. A third-generation dual-source multidetector CT scanner (Siemens SOMATOM FORCE; Siemens Healthcare AG, Erlangen, Germany) running advanced modeled iterative reconstruction (ADMIRE) software (Siemens Healthcare AG) was used.We used normal and very large body habitus rings at dose levels varying from 1.5 to 0.15 mGy using a spectral-shaped (0.6-mm Sn) tube output of 100 kV(p). Three CT scans were obtained at each dose level using both rings. Regions of interest for each material in the test object scans were automatically extracted. The Hounsfield unit values of each material using weighted filtered back projection (WFBP) at 1.5 mGy was used as the reference value to evaluate shifts in CT attenuation at lower dose levels using either WFBP or ADMIRE. Statistical analysis included basic statistics, Welch t tests, multivariable covariant model using the F test to assess the significance of the explanatory (independent) variables on the response (dependent) variable, and CT mean attenuation, in the multivariable covariant model including reconstruction method. Multivariable regression analysis of the mean CT attenuation values showed a significant difference with decreasing dose between ADMIRE and WFBP. The ADMIRE has reduced noise and more stable CT attenuation compared with WFBP. There was a strong effect on the mean CT attenuation values of the scanned materials for ring size (P < 0.0001) and dose level (P < 0.0001). The number of voxels in the region of interest for the particular material studied did not demonstrate a significant effect (P > 0.05). The SD was lower with ADMIRE compared with WFBP at all dose levels and ring sizes (P < 0.05). The third-generation dual-source CT scanners using third-generation iterative reconstruction methods can acquire accurate quantitative CT images with acceptable image noise at very low-dose levels (0.15 mGy). This opens up new diagnostic and research opportunities in CT phenotyping of the lung for developing new treatments and increased understanding of pulmonary disease.

  14. Low-dose CT in clinical diagnostics.

    PubMed

    Fuentes-Orrego, Jorge M; Sahani, Dushyant V

    2013-09-01

    Computed tomography (CT) has become key for patient management due to its outstanding capabilities for detecting disease processes and assessing treatment response, which has led to expansion in CT imaging for diagnostic and image-guided therapeutic interventions. Despite these benefits, the growing use of CT has raised concerns as radiation risks associated with radiation exposure. The purpose of this article is to familiarize the reader with fundamental concepts of dose metrics for assessing radiation exposure and weighting radiation-associated risks. The article also discusses general approaches for reducing radiation dose while preserving diagnostic quality. The authors provide additional insight for undertaking protocol optimization, customizing scanning techniques based on the patients' clinical scenario and demographics. Supplemental strategies are postulated using more advanced post-processing techniques for achieving further dose improvements. The technologic offerings of CT are integral to modern medicine and its role will continue to evolve. Although, the estimated risks from low levels of radiation of a single CT exam are uncertain, it is prudent to minimize the dose from CT by applying common sense solutions and using other simple strategies as well as exploiting technologic innovations. These efforts will enable us to take advantage of all the clinical benefits of CT while minimizing the likelihood of harm to patients.

  15. Using three-dimensional-computerized tomography as a diagnostic tool for temporo-mandibular joint ankylosis: a case report.

    PubMed

    Kao, S Y; Chou, J; Lo, J; Yang, J; Chou, A P; Joe, C J; Chang, R C

    1999-04-01

    Roentgenographic examination has long been a useful diagnostic tool for temporo-mandibular joint (TMJ) disease. The methods include TMJ tomography, panoramic radiography and computerized tomography (CT) scan with or without injection of contrast media. Recently, three-dimensional CT (3D-CT), reconstructed from the two-dimensional image of a CT scan to simulate the soft tissue or bony structure of the real target, was proposed. In this report, a case of TMJ ankylosis due to traumatic injury is presented. 3D-CT was employed as one of the presurgical roentgenographic diagnostic tools. The conventional radiographic examination including panoramic radiography and tomography showed lesions in both sides of the mandible. CT scanning further suggested that the right-sided lesion was more severe than that on the left. With 3D-CT image reconstruction the size and extent of the lesions were clearly observable. The decision was made to proceed with an initial surgical approach on the right side. With condylectomy and condylar replacement using an autogenous costochondral graft on the right side, the range of mouth opening improved significantly. In this case report, 3D-CT demonstrates its advantages as a tool for the correct and precise diagnosis of TMJ ankylosis.

  16. (18)F-FDG uptake predicts diagnostic yield of transbronchial biopsy in peripheral lung cancer.

    PubMed

    Umeda, Yukihiro; Demura, Yoshiki; Anzai, Masaki; Matsuoka, Hiroki; Araya, Tomoyuki; Nishitsuji, Masaru; Nishi, Koichi; Tsuchida, Tatsuro; Sumida, Yasuyuki; Morikawa, Miwa; Ameshima, Shingo; Ishizaki, Takeshi; Kasahara, Kazuo; Ishizuka, Tamotsu

    2014-07-01

    Recent advances in endobronchial ultrasonography with a guide sheath (EBUS-GS) have enabled better visualization of distal airways, while virtual bronchoscopic navigation (VBN) has been shown useful as a guide to navigate the bronchoscope. However, indications for utilizing VBN and EBUS-GS are not always clear. To clarify indications for a bronchoscopic examination using VBN and EBUS-GS, we evaluated factors that predict the diagnostic yield of a transbronchial biopsy (TBB) procedure for peripheral lung cancer (PLC) lesions. We retrospectively reviewed the charts of 194 patients with 201 PLC lesions (≤3cm mean diameter), and analyzed the association of diagnostic yield of TBB with [(18)F]-fluoro-2-deoxy-d-glucose ((18)F-FDG) positron emission tomography and chest computed tomography (CT) findings. The diagnostic yield of TBB using VBN and EBUS-GS was 66.7%. High maximum standardized uptake value (SUVmax), positive bronchus sign, and ground-glass opacity component shown on CT were all significant predictors of diagnostic yield, while multivariate analysis showed only high (18)F-FDG uptake (SUVmax ≥2.8) and positive bronchus sign as significant predictors. Diagnostic yield was higher for PLC lesions with high (18)F-FDG uptake (SUVmax ≥2.8) and positive bronchus sign (84.6%) than for those with SUVmax <2.8 and negative bronchus sign (33.3%). High (18)F-FDG uptake was also correlated with tumor invasiveness. High (18)F-FDG uptake predicted the diagnostic yield of TBB using VBN and EBUS-GS for PLC lesions. (18)F-FDG uptake and bronchus sign may indicate for the accurate application of bronchoscopy with those modalities for diagnosing PLC. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. The diagnostic test accuracy of magnetic resonance imaging, magnetic resonance arthrography and computer tomography in the detection of chondral lesions of the hip.

    PubMed

    Smith, Toby O; Simpson, Michael; Ejindu, Vivian; Hing, Caroline B

    2013-04-01

    The purpose of this study was to assess the diagnostic test accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and multidetector arrays in CT arthrography (MDCT) for assessing chondral lesions in the hip joint. A review of the published and unpublished literature databases was performed to identify all studies reporting the diagnostic test accuracy (sensitivity/specificity) of MRI, MRA or MDCT for the assessment of adults with chondral (cartilage) lesions of the hip with surgical comparison (arthroscopic or open) as the reference test. All included studies were reviewed using the quality assessment of diagnostic accuracy studies appraisal tool. Pooled sensitivity, specificity, likelihood ratios and diagnostic odds ratios were calculated with 95 % confidence intervals using a random-effects meta-analysis for MRI, MRA and MDCT imaging. Eighteen studies satisfied the eligibility criteria. These included 648 hips from 637 patients. MRI indicated a pooled sensitivity of 0.59 (95 % CI: 0.49-0.70) and specificity of 0.94 (95 % CI: 0.90-0.97), and MRA sensitivity and specificity values were 0.62 (95 % CI: 0.57-0.66) and 0.86 (95 % CI: 0.83-0.89), respectively. The diagnostic test accuracy for the detection of hip joint cartilage lesions is currently superior for MRI compared with MRA. There were insufficient data to perform meta-analysis for MDCT or CTA protocols. Based on the current limited diagnostic test accuracy of the use of magnetic resonance or CT, arthroscopy remains the most accurate method of assessing chondral lesions in the hip joint.

  18. 18F-DOPA PET/CT and 68Ga-DOTANOC PET/CT scans as diagnostic tools in focal congenital hyperinsulinism: a blinded evaluation.

    PubMed

    Christiansen, Charlotte Dahl; Petersen, Henrik; Nielsen, Anne Lerberg; Detlefsen, Sönke; Brusgaard, Klaus; Rasmussen, Lars; Melikyan, Maria; Ekström, Klas; Globa, Evgenia; Rasmussen, Annett Helleskov; Hovendal, Claus; Christesen, Henrik Thybo

    2018-02-01

    Focal congenital hyperinsulinism (CHI) is curable by surgery, which is why identification of the focal lesion is crucial. We aimed to determine the use of 18F-fluoro-dihydroxyphenylalanine (18F-DOPA) PET/CT vs. 68Ga-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic-acid-1-Nal3-octreotide (68Ga-DOTANOC) PET/CT as diagnostic tools in focal CHI. PET/CT scans of children with CHI admitted to Odense University Hospital between August 2005 and June 2016 were retrospectively evaluated visually and by their maximal standardized uptake values (SUV max ) by two independent examiners, blinded for clinical, surgical and pathological data. Pancreatic histology was used as the gold standard. For patients without surgery, the genetic profile served as the gold standard. Fifty-five CHI patients were examined by PET/CT (18F-DOPA n = 53, 68Ga-DOTANOC n = 18). Surgery was performed in 34 patients, no surgery in 21 patients. Fifty-one patients had a classifiable outcome, either by histology (n = 33, 22 focal lesions, 11 non-focal) or by genetics (n = 18, all non-focal). The predictive performance of 18F-DOPA PET/CT to identify focal CHI was identical by visual- and cut-off-based evaluation: sensitivity (95% CI) of 1 (0.85-1); specificity of 0.96 (0.82-0.99). The optimal 18F-DOPA PET SUV max ratio cut-off was 1.44 and the optimal 68Ga-DOTANOC PET SUV max cut-off was 6.77 g/ml. The area under the receiver operating curve was 0.98 (0.93-1) for 18F-DOPA PET vs. 0.71 (0.43-0.95) for 68Ga-DOTANOC PET (p < 0.03). In patients subjected to surgery, localization of the focal lesion was correct in 91%, and 100%, by 18F-DOPA PET/CT and 68Ga-DOTANOC PET/CT, respectively. 18F-DOPA PET/CT was excellent in predicting focal CHI and superior compared to 68Ga-DOTANOC PET/CT. Further use of 68GA-DOTANOC PET/CT in predicting focal CHI is discouraged.

  19. Detection of thoracic aortic prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography.

    PubMed

    Tokuda, Yoshiyuki; Oshima, Hideki; Araki, Yoshimori; Narita, Yuji; Mutsuga, Masato; Kato, Katsuhiko; Usui, Akihiko

    2013-06-01

    To investigate the diagnostic value of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in detecting thoracic aortic prosthetic graft infection. Nine patients with clinically suspected thoracic aortic graft infection underwent FDG-PET/CT scanning. In these patients, the diagnoses could not be confirmed using conventional modalities. The patients' clinical courses were retrospectively reviewed. On the basis of surgical, microbiological and clinical follow-up findings, the aortic grafts were considered infected in 4 patients and not infected in 5. All 4 patients with graft infection (root: 2 cases, arch: 1 case and descending: 1 case) eventually underwent in situ re-replacement. Two of the 4 patients also had abdominal grafts; however, only the thoracic grafts were replaced because uptake was low around the abdominal grafts. The maximal standardized uptake value (SUVmax) in the perigraft area was higher in the infected group than in the non-infected group (11.4 ± 4.5 vs 6.9 ± 6.4), although the difference was not statistically significant. According to the receiver operating characteristic analysis, SUVmax >8 appeared to be the cut-off value in distinguishing the two groups (sensitivity: 1.0 and specificity: 0.8). FDG-PET/CT is useful for confirming the presence of graft infection by detecting high uptake around grafts and excluding other causes of inflammation. An SUVmax value greater than 8 around a graft suggests the presence of graft infection. In addition, FDG-PET/CT can be used to clarify the precise extent of infection. This is especially useful if multiple separated prosthetic grafts have been implanted.

  20. Diagnostic performance of a Lattice Boltzmann-based method for CT-based fractional flow reserve.

    PubMed

    Giannopoulos, Andreas A; Tang, Anji; Ge, Yin; Cheezum, Michael K; Steigner, Michael L; Fujimoto, Shinichiro; Kumamaru, Kanako K; Chiappino, Dante; Della Latta, Daniele; Berti, Sergio; Chiappino, Sara; Rybicki, Frank J; Melchionna, Simone; Mitsouras, Dimitrios

    2018-02-20

    Fractional flow reserve (FFR) estimated from coronary computed tomography angiography (CT-FFR) offers non-invasive detection of lesion-specific ischaemia. We aimed to develop and validate a fast CT-FFR algorithm utilising the Lattice Boltzmann method for blood flow simulation (LBM CT-FFR). Sixty-four patients with clinically indicated CTA and invasive FFR measurement from three institutions were retrospectively analysed. CT-FFR was performed using an onsite tool interfacing with a commercial Lattice Boltzmann fluid dynamics cloud-based platform. Diagnostic accuracy of LBM CT-FFR ≤0.8 and percent diameter stenosis >50% by CTA to detect invasive FFR ≤0.8 were compared using area under the receiver operating characteristic curve (AUC). Sixty patients successfully underwent LBM CT-FFR analysis; 29 of 73 lesions in 69 vessels had invasive FFR ≤0.8. Total time to perform LBM CT-FFR was 40±10 min. Compared to invasive FFR, LBM CT-FFR had good correlation (r=0.64), small bias (0.009) and good limits of agreement (-0.223 to 0.206). The AUC of LBM CT-FFR (AUC=0.894, 95% confidence interval [CI]: 0.792-0.996) was significantly higher than CTA (AUC=0.685, 95% CI: 0.576-0.794) to detect FFR ≤0.8 (p=0.0021). Per-lesion specificity, sensitivity, and accuracy of LBM CT-FFR were 97.7%, 79.3%, and 90.4%, respectively. LBM CT-FFR has very good diagnostic accuracy to detect lesion-specific ischaemia (FFR ≤0.8) and can be performed in less than one hour.

  1. Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants: comparison with transthoracic echocardiography.

    PubMed

    Goo, Hyun Woo

    2018-02-01

    Considering inherent limitations of transthoracic echocardiography, the diagnostic accuracy of cardiac CT in identifying coronary artery anatomy before arterial switch operation needs to be investigated with recently improved coronary artery visibility using electrocardiogram (ECG)-synchronized dual-source CT. To compare diagnostic accuracy between cardiac CT using a dual-source scanner and transthoracic echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. The study included 101 infants (median age 4 days, range 0 days to 10 months; M:F=78:23) who underwent ECG-synchronized cardiac dual-source CT and transthoracic echocardiography before arterial switch operation between July 2011 and December 2016. We evaluated and classified coronary artery anatomy on cardiac CT and transthoracic echocardiography. With the surgical findings as the reference standard, we compared the diagnostic accuracy for identifying coronary artery anatomy between cardiac CT and transthoracic echocardiography. The most common coronary artery pattern was the usual pattern (left coronary artery from sinus 1 and right coronary artery from sinus 2; 64.4%, 65/101), followed by a single coronary artery from sinus 2 and a conal branch from sinus 1 (7.9%, 8/101), the inverted pattern (5.9%, 6/101), the right coronary artery and left anterior descending artery from sinus 1 and the left circumflex artery from sinus 2 (5.9%, 6/101), and others. In 96 infants with surgically proven coronary artery anatomy, the diagnostic accuracy of cardiac CT was significantly higher than that of transthoracic echocardiography (91.7%, 88/96 vs. 54.2%, 52/96; P<0.0001). Diagnostic accuracy of cardiac CT is significantly higher than that of echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants.

  2. The impact of diagnostic imaging wait times on the prognosis of lung cancer.

    PubMed

    Byrne, Suzanne C; Barrett, Brendan; Bhatia, Rick

    2015-02-01

    This study was performed to determine whether gaps in patient flow from initial lung imaging to computed tomography (CT) guided lung biopsy in patients with non-small cell lung cancer (NSCLC) was associated with a change in tumour size, stage, and thus prognosis. All patients who had a CT-guided lung biopsy in 2009 (phase I) and in 2011 (phase II) with a pathologic diagnosis of primary lung cancer (NSCLC) at Eastern Health, Newfoundland, were identified. Dates of initial abnormal imaging, confirmatory CT (if performed), and CT-guided biopsy were recorded, along with tumour size and resulting T stage at each time point. In 2010, wait times for diagnostic imaging at Eastern Health were reduced. The stage and prognosis of NSCLC in 2009 was compared with 2011. In phase 1, there was a statistically significant increase in tumour size (mean difference, 0.67 cm; P < .0001) and stage (P < .0001) from initial image to biopsy. There was a moderate correlation between the time (in days) between the images and change in size (r = 0.33, P = .008) or stage (r = 0.26, P = .036). In phase II, the median wait time from initial imaging to confirmatory CT was reduced to 7.5 days (from 19 days). At this reduced wait time, there was no statistically significant increase in tumour size (mean difference, 0.02; P > .05) or stage (P > .05) from initial imaging to confirmatory CT. Delays in patient flow through diagnostic imaging resulted in an increase in tumour size and stage, with a negative impact on prognosis of NSCLC. This information contributed to the hiring of additional CT technologists and extended CT hours to decrease the wait time for diagnostic imaging. With reduced wait times, the prognosis of NSCLC was not adversely impacted as patients navigated through diagnostic imaging. Copyright © 2015 Canadian Association of Radiologists. All rights reserved.

  3. Solitary pulmonary nodule evaluation in regions endemic for infectious diseases: Do regional variations impact the effectiveness of fluorodeoxyglucose positron emission tomography/computed tomography.

    PubMed

    Purandare, N C; Pramesh, C S; Agarwal, J P; Agrawal, A; Shah, S; Prabhash, K; Karimundackal, G; Jiwnani, S; Tandon, S; Rangarajan, V

    2017-01-01

    Fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) has become a preferred imaging modality for the evaluation of solitary pulmonary nodule (SPN), particularly in the developed world. Since FDG can concentrate in infective/inflammatory lesions, the diagnostic utility of FDG-PET can be questioned, particularly in regions endemic for infectious decisions. To evaluate the accuracy of FDG-PET/CT in evaluation of SPNs in a population endemic for infectious disease and to assess if regional variations have an impact on its effectiveness. All patients who underwent an FDG/PET-CT with a clinico-radiological diagnosis of SPN categorized as indeterminate were included. Based on a maximum standardized uptake values (SUVmax) cut-off of 2.5, lesions were classified as benign (<2.5) or malignant (>2.5) and compared with gold standard histopathology. The diagnostic accuracy of PET-CT to detect malignancy was calculated. On the basis of final histopathology, lesions were grouped as (a) malignant nodules (b) infective/granulomatous nodules with a specific diagnosis and (c) nonspecific inflammatory nodules. The SUVmaxbetween these groups was compared using nonparametric statistical tests. A total of 191 patients (129 males, 62 females) with a median age of 64 years (range: 36-83) were included. Totally, 144 nodules (75.3%) were malignant and 47 were benign (24.7%). Adenocarcinoma (n = 84) was the most common malignancy. Tuberculosis (n = 16) and nonspecific infections (n = 24) were the two most common benign pathologies. There was a significant overlap in the metabolic uptake of malignant (median SUVmax-11.2, range: 3.3-34.6) and tuberculous nodules (median SUVmax-10.3, range: 2.7-22.5) with no statistically difference between their SUVmaxvalues (P = 0.43). The false-positive rate was 65.2% and the false-negative rate was 5.5%. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FDG-PET/CT for detecting malignancy were 94.4%, 34.7%, 81.9%, 66.6%, and 79.5%, respectively. Though FDG-PET scans show a very high sensitivity for malignant nodules, it has a high false-positive rate and reduced specificity when characterizing SPNs in an infectious endemic region. Physicians must be aware of this limitation in the workup of lung nodules, and regional variations must be considered before further management decisions are taken.

  4. Magnetic Resonance Imaging of Pulmonary Embolism: Diagnostic Accuracy of Unenhanced MR and Influence in Mortality Rates.

    PubMed

    Pasin, Lilian; Zanon, Matheus; Moreira, Jose; Moreira, Ana Luiza; Watte, Guilherme; Marchiori, Edson; Hochhegger, Bruno

    2017-04-01

    We evaluated the diagnostic value for pulmonary embolism (PE) of the True fast imaging with steady-state precession (TrueFISP) MRI, a method that allows the visualization of pulmonary vasculature without breath holding or intravenous contrast. This is a prospective investigation including 93 patients with suspected PE. All patients underwent TrueFISP MRI after undergoing CT pulmonary angiography (CTPA). Two independent readers evaluated each MR study, and consensus was obtained. CTPA results were analysed by a third independent reviewer and these results served as the reference standard. A fourth radiologist was responsible for evaluating if lesions found on MRI for both analysis were the same and if these were the correspondent lesions on the CTPA. Sensitivity, specificity, predictive values and accuracy were calculated. Evidence for death from PE within the 1-year follow-up was also assessed. Two patients could not undergo the real-time MRI and were excluded from the study. PE prevalence was 22%. During the 1-year follow-up period, eight patients died, whereas PE was responsible for 12.5% of cases. Between patients who developed PE, only 5% died due to this condition. There were no differences between MR and CT embolism detection in these subjects. MR sequences had a sensitivity of 85%, specificity was 98.6% and accuracy was 95.6%. Agreement between readers was high (κ= 0.87). Compared with contrast-enhanced CT, unenhanced MR sequences demonstrate good accuracy and no differences in the mortality rates in 1 year were detected.

  5. Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR).

    PubMed

    Notohamiprodjo, S; Deak, Z; Meurer, F; Maertz, F; Mueck, F G; Geyer, L L; Wirth, S

    2015-01-01

    The purpose of this study was to compare cranial CT (CCT) image quality (IQ) of the MBIR algorithm with standard iterative reconstruction (ASiR). In this institutional review board (IRB)-approved study, raw data sets of 100 unenhanced CCT examinations (120 kV, 50-260 mAs, 20 mm collimation, 0.984 pitch) were reconstructed with both ASiR and MBIR. Signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated from attenuation values measured in caudate nucleus, frontal white matter, anterior ventricle horn, fourth ventricle, and pons. Two radiologists, who were blinded to the reconstruction algorithms, evaluated anonymized multiplanar reformations of 2.5 mm with respect to depiction of different parenchymal structures and impact of artefacts on IQ with a five-point scale (0: unacceptable, 1: less than average, 2: average, 3: above average, 4: excellent). MBIR decreased artefacts more effectively than ASiR (p < 0.01). The median depiction score for MBIR was 3, whereas the median value for ASiR was 2 (p < 0.01). SNR and CNR were significantly higher in MBIR than ASiR (p < 0.01). MBIR showed significant improvement of IQ parameters compared to ASiR. As CCT is an examination that is frequently required, the use of MBIR may allow for substantial reduction of radiation exposure caused by medical diagnostics. • Model-Based iterative reconstruction (MBIR) effectively decreased artefacts in cranial CT. • MBIR reconstructed images were rated with significantly higher scores for image quality. • Model-Based iterative reconstruction may allow reduced-dose diagnostic examination protocols.

  6. SU-E-I-33: Establishment of CT Diagnostic Reference Levels in Province Nova Scotia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tonkopi, E; Abdolell, M; Duffy, S

    2015-06-15

    Purpose: To evaluate patient radiation dose from the most frequently performed CT examinations and to establish provincial diagnostic reference levels (DRLs) as a tool for protocol optimization. Methods: The study investigated the following CT examinations: head, chest, abdomen/pelvis, and chest/abdomen/pelvis (CAP). Dose data, volume CT dose index (CTDIvol) and dose-length product (DLP), were collected from 15 CT scanners installed during 2004–2014 in 11 hospital sites of Nova Scotia. All scanners had dose modulation options and multislice capability (16–128 detector rows). The sample for each protocol included 15 average size patients (70±20 kg). Provincial DRLs were calculated as the 75th percentilemore » of patient dose distributions. The differences in dose between hospitals were evaluated with a single factor ANOVA statistical test. Generalized linear modeling was used to determine the factors associated with higher radiation dose. A sample of 36 abdominal studies performed on three different scanners was blinded and randomized for an assessment by an experienced radiologist who graded the imaging quality of anatomic structures. Results: Data for 900 patients were collected. The DRLs were proposed using CTDIvol (mGy) and DLP (mGy*cm) values for CT head (67 and 1049, respectively), chest (12 and 393), abdomen/pelvis (16 and 717), and CAP (14 and 1034). These DRLs were lower than the published national data except for the head CTDIvol. The differences between the means of the dose distributions from each scanner were statistically significant (p<0.05) for all examinations. A very weak correlation was found between the dose and the scanner age or the number of slices with Pearson’s correlation coefficients of 0.011–0.315. The blinded analysis of image quality demonstrated no clinically significant difference except for the noise category. Conclusion: Provincial DRLs were established for typical CT examinations. The variations in dose between the hospitals suggested a large potential for optimization of examinations. Radiology Research Foundation grant.« less

  7. Is MRI of the Liver Needed During Routine Preoperative Workup for Colorectal Cancer?

    PubMed

    Kang, Sung Il; Kim, Duck-Woo; Cho, Jai Young; Park, Jihoon; Lee, Kyung Ho; Son, Il Tae; Oh, Heung-Kwon; Kang, Sung-Bum

    2017-09-01

    The clinical efficacy of gadoxetic acid-enhanced liver MRI as a routine preoperative procedure for all patients with colorectal cancer remains unclear. The purpose of this study was to evaluate the efficacy of preoperative gadoxetic acid-enhanced liver MRI for the diagnosis of liver metastasis in patients with colorectal cancer. This was a retrospective analysis from a prospective cohort database. All of the patients were from a subspecialty practice at a tertiary referral hospital. Patients who received preoperative gadoxetic acid-enhanced liver MRI after CT and attempted curative surgery for colorectal cancer were included. The number of equivocal hepatic lesions based on CT and gadoxetic acid-enhanced liver MRI and diagnostic use of the gadoxetic acid-enhanced liver MRI were measured. We reviewed the records of 690 patients with colorectal cancer. Equivocal hepatic lesions were present in 17.2% of patients based on CT and in 4.5% based on gadoxetic acid-enhanced liver MRI. Among 496 patients with no liver metastasis based on CT, gadoxetic acid-enhanced liver MRI detected equivocal lesions in 15 patients and metastasis in 3 patients. Among 119 patients who had equivocal liver lesions on CT, gadoxetic acid-enhanced liver MRI indicated hepatic lesions in 103 patients (86.6%), including 90 with no metastasis and 13 with metastasis. Among 75 patients who had liver metastasis on CT, gadoxetic acid-enhanced liver MRI indicated that the hepatic lesions in 2 patients were benign, in contrast to CT findings. The initial surgical plans for hepatic lesions according to CT were changed in 17 patients (3%) after gadoxetic acid-enhanced liver MRI. This study was limited by its retrospective design. The clinical efficacy of gadoxetic acid-enhanced liver MRI as a routine preoperative procedure for all patients with colorectal cancer is low, in spite of its high diagnostic value for detecting liver metastasis. However, this study showed gadoxetic acid-enhanced liver MRI was helpful in characterizing equivocal hepatic lesions identified in CT and could lead to change in treatment plans for some patients. See Video Abstract at http://links.lww.com/DCR/A420.

  8. Radiation dose-reduction strategies in thoracic CT.

    PubMed

    Moser, J B; Sheard, S L; Edyvean, S; Vlahos, I

    2017-05-01

    Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. An integrated teaching method of gross anatomy and computed tomography radiology.

    PubMed

    Murakami, Tohru; Tajika, Yuki; Ueno, Hitoshi; Awata, Sachiko; Hirasawa, Satoshi; Sugimoto, Maki; Kominato, Yoshihiko; Tsushima, Yoshito; Endo, Keigo; Yorifuji, Hiroshi

    2014-01-01

    It is essential for medical students to learn and comprehend human anatomy in three dimensions (3D). With this in mind, a new system was designed in order to integrate anatomical dissections with diagnostic computed tomography (CT) radiology. Cadavers were scanned by CT scanners, and students then consulted the postmortem CT images during cadaver dissection to gain a better understanding of 3D human anatomy and diagnostic radiology. Students used handheld digital imaging and communications in medicine viewers at the bench-side (OsiriX on iPod touch or iPad), which enabled "pixel-to-tissue" direct comparisons of CT images and cadavers. Students had lectures and workshops on diagnostic radiology, and they completed study assignments where they discussed findings in the anatomy laboratory compared with CT radiology findings. This teaching method for gross and radiological anatomy was used beginning in 2009, and it yielded strongly positive student perspectives and significant improvements in radiology skills in later clinical courses. © 2014 American Association of Anatomists.

  10. Experimental benchmarking of a Monte Carlo dose simulation code for pediatric CT

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Samei, Ehsan; Yoshizumi, Terry; Colsher, James G.; Jones, Robert P.; Frush, Donald P.

    2007-03-01

    In recent years, there has been a desire to reduce CT radiation dose to children because of their susceptibility and prolonged risk for cancer induction. Concerns arise, however, as to the impact of dose reduction on image quality and thus potentially on diagnostic accuracy. To study the dose and image quality relationship, we are developing a simulation code to calculate organ dose in pediatric CT patients. To benchmark this code, a cylindrical phantom was built to represent a pediatric torso, which allows measurements of dose distributions from its center to its periphery. Dose distributions for axial CT scans were measured on a 64-slice multidetector CT (MDCT) scanner (GE Healthcare, Chalfont St. Giles, UK). The same measurements were simulated using a Monte Carlo code (PENELOPE, Universitat de Barcelona) with the applicable CT geometry including bowtie filter. The deviations between simulated and measured dose values were generally within 5%. To our knowledge, this work is one of the first attempts to compare measured radial dose distributions on a cylindrical phantom with Monte Carlo simulated results. It provides a simple and effective method for benchmarking organ dose simulation codes and demonstrates the potential of Monte Carlo simulation for investigating the relationship between dose and image quality for pediatric CT patients.

  11. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    PubMed

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  12. Diagnostic implications of a small-voxel reconstruction for loco-regional lymph node characterization in breast cancer patients using FDG-PET/CT.

    PubMed

    Koopman, Daniëlle; van Dalen, Jorn A; Arkies, Hester; Oostdijk, Ad H J; Francken, Anne Brecht; Bart, Jos; Slump, Cornelis H; Knollema, Siert; Jager, Pieter L

    2018-01-16

    We evaluated the diagnostic implications of a small-voxel reconstruction for lymph node characterization in breast cancer patients, using state-of-the-art FDG-PET/CT. We included 69 FDG-PET/CT scans from breast cancer patients. PET data were reconstructed using standard 4 × 4 × 4 mm 3 and small 2 × 2 × 2 mm 3 voxels. Two hundred thirty loco-regional lymph nodes were included, of which 209 nodes were visualised on PET/CT. All nodes were visually scored as benign or malignant, and SUV max and TB ratio (=SUV max /SUV background ) were measured. Final diagnosis was based on histological or imaging information. We determined the accuracy, sensitivity and specificity for both reconstruction methods and calculated optimal cut-off values to distinguish benign from malignant nodes. Sixty-one benign and 169 malignant lymph nodes were included. Visual evaluation accuracy was 73% (sensitivity 67%, specificity 89%) on standard-voxel images and 77% (sensitivity 78%, specificity 74%) on small-voxel images (p = 0.13). Across malignant nodes visualised on PET/CT, the small-voxel score was more often correct compared with the standard-voxel score (89 vs. 76%, p <  0.001). In benign nodes, the standard-voxel score was more often correct (89 vs. 74%, p = 0.04). Quantitative data were based on the 61 benign and 148 malignant lymph nodes visualised on PET/CT. SUVs and TB ratio were on average 3.0 and 1.6 times higher in malignant nodes compared to those in benign nodes (p <  0.001), on standard- and small-voxel PET images respectively. Small-voxel PET showed average increases in SUV max and TB ratio of typically 40% over standard-voxel PET. The optimal SUV max cut-off using standard-voxels was 1.8 (sensitivity 81%, specificity 95%, accuracy 85%) while for small-voxels, the optimal SUV max cut-off was 2.6 (sensitivity 78%, specificity 98%, accuracy 84%). Differences in accuracy were non-significant. Small-voxel PET/CT improves the sensitivity of visual lymph node characterization and provides a higher detection rate of malignant lymph nodes. However, small-voxel PET/CT also introduced more false-positive results in benign nodes. Across all nodes, differences in accuracy were non-significant. Quantitatively, small-voxel images require higher cut-off values. Readers have to adapt their reference standards.

  13. [Radiological diagnostics in CUP syndrome].

    PubMed

    Kazmierczak, P M; Nikolaou, K; Rominger, A; Graser, A; Reiser, M F; Cyran, C C

    2014-02-01

    Imaging plays an essential role in the therapeutic management of cancer of unknown primary (CUP) patients for localizing the primary tumor, for the identification of tumor entities for which a dedicated therapy regimen is available and for the characterization of clinicopathological subentities that direct the subsequent diagnostic and therapeutic strategy. Modalities include conventional x-ray, computed tomography (CT), magnetic resonance imaging (MRI) and ultrasound as well as positron emission tomography (PET)-CT and MRI-PET. In whole body imaging CT has a high sensitivity for tumor entities which frequently present as a metastasized cancer illness. According to the current literature CT is diagnostic in 86% of patients with pancreatic carcinoma, in 36% of patients with colon carcinoma and in 74% of patients with lung carcinoma. Additionally a meta-analysis showed that for patients with squamous cell carcinoma and cervical lymph node metastases a positive diagnosis was possible in 22% of the cases using CT, in 36% using MRI and in 28-57% using 18F-fluorodeoxyglucose PET-CT ((18)F-FDG PET-CT). In addition, MRI plays an important role in the localization of primary occult tumors (e.g. breast and prostate) because of its high soft tissue contrast and options for functional imaging. At the beginning of the diagnostic algorithm stands the search for a possible primary tumor and CT of the neck, thorax and abdomen is most frequently used for whole body staging. Subsequent organ-specific imaging examinations follow, e.g. mammography in women with axillary lymphadenopathy. For histological and immunohistochemical characterization of tumor tissue, imaging is also applied to identify the most accessible and representative tumor manifestation for biopsy. Tumor biopsy may be guided by CT, MRI or ultrasound and MRI also plays a central role in the localization of primary occult tumors because of superior soft tissue contrast and options for functional imaging (perfusion, diffusion), e.g. investigation of breast carcinoma or prostate carcinoma. Whole body staging stands at the beginning of the diagnostic algorithm in CUP syndrome to localize a potential primary tumor. Clinically, contrast-enhanced CT of the neck, thorax and abdomen is frequently applied; however, many studies have demonstrated augmented sensitivity of (18)F-FDG PET-CT for the detection of primary tumors and metastatic tumor manifestations.

  14. Impact of knowledge-based iterative model reconstruction on myocardial late iodine enhancement in computed tomography and comparison with cardiac magnetic resonance.

    PubMed

    Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Fukuyama, Naoki; Yokoi, Takahiro; Kido, Tomoyuki; Uetani, Teruyoshi; Vembar, Mani; Dhanantwari, Amar; Tokuyasu, Shinichi; Yamashita, Natsumi; Mochizuki, Teruhito

    2017-10-01

    We evaluated the image quality and diagnostic performance of late iodine enhancement computed tomography (LIE-CT) with knowledge-based iterative model reconstruction (IMR) for the detection of myocardial infarction (MI) in comparison with late gadolinium enhancement magnetic resonance imaging (LGE-MRI). The study investigated 35 patients who underwent a comprehensive cardiac CT protocol and LGE-MRI for the assessment of coronary artery disease. The CT protocol consisted of stress dynamic myocardial CT perfusion, coronary CT angiography (CTA) and LIE-CT using 256-slice CT. LIE-CT scans were acquired 5 min after CTA without additional contrast medium and reconstructed with filtered back projection (FBP), a hybrid iterative reconstruction (HIR), and IMR. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed. Sensitivity and specificity of LIE-CT for detecting MI were assessed according to the 16-segment model. Image quality scores, and diagnostic performance were compared among LIE-CT with FBP, HIR and IMR. Among the 35 patients, 139 of 560 segments showed MI in LGE-MRI. On LIE-CT with FBP, HIR, and IMR, the median SNRs were 2.1, 2.9, and 6.1; and the median CNRs were 1.7, 2.2, and 4.7, respectively. Sensitivity and specificity were 56 and 93% for FBP, 62 and 91% for HIR, and 80 and 91% for IMR. LIE-CT with IMR showed the highest image quality and sensitivity (p < 0.05). The use of IMR enables significant improvement of image quality and diagnostic performance of LIE-CT for detecting MI in comparison with FBP and HIR.

  15. Quantitative analysis of computed tomography images and early detection of cerebral edema for pediatric traumatic brain injury patients: retrospective study.

    PubMed

    Kim, Hakseung; Kim, Gwang-dong; Yoon, Byung C; Kim, Keewon; Kim, Byung-Jo; Choi, Young Hun; Czosnyka, Marek; Oh, Byung-Mo; Kim, Dong-Joo

    2014-10-22

    The purpose of this study was to identify whether the distribution of Hounsfield Unit (HU) values across the intracranial area in computed tomography (CT) images can be used as an effective diagnostic tool for determining the severity of cerebral edema in pediatric traumatic brain injury (TBI) patients. CT images, medical records and radiology reports on 70 pediatric patients were collected. Based on radiology reports and the Marshall classification, the patients were grouped as mild edema patients (n=37) or severe edema patients (n=33). Automated quantitative analysis using unenhanced CT images was applied to eliminate artifacts and identify the difference in HU value distribution across the intracranial area between these groups. The proportion of pixels with HU=17 to 24 was highly correlated with the existence of severe cerebral edema (P<0.01). This proportion was also able to differentiate patients who developed delayed cerebral edema from mild TBI patients. A significant difference between deceased patients and surviving patients in terms of the HU distribution came from the proportion of pixels with HU=19 to HU=23 (P<0.01). The proportion of pixels with an HU value of 17 to 24 in the entire cerebral area of a non-enhanced CT image can be an effective basis for evaluating the severity of cerebral edema. Based on this result, we propose a novel approach for the early detection of severe cerebral edema.

  16. Imaging in primary hyperparathyroidism: focus on the evidence-based diagnostic performance of different methods.

    PubMed

    Treglia, Giorgio; Trimboli, Pierpaolo; Huellner, Martin; Giovanella, Luca

    2018-06-01

    Primary hyperparathyroidism (PHPT) is a common endocrine disorder usually due to hyperfunctioning parathyroid glands (HP). Surgical removal of HP is the main treatment in PHPT, particularly in symptomatic patients. The correct detection and localization of HP is challenging and crucial as it may guide surgical treatment in patients with PHPT. To date, different imaging methods have been used to detect and localize HP in patients with PHPT including radiology, nuclear medicine and hybrid techniques. This review was focused to describe the diagnostic performance of several imaging methods used in detecting HP in patients with PHPT. We have summarized the diagnostic performance of different imaging methods used in detecting HP in patients with PHPT taking into account recent evidence-based articles published in the literature. To this regard, findings of recently published meta-analyses on the diagnostic accuracy of imaging methods in PHPT were reported. Furthermore, a suggested imaging strategy taking into account the diagnostic performance and further consideration has been described. Cervical ultrasound (US) and parathyroid scintigraphy using 99mTc-MIBI are the most commonly employed first-line investigations in patients with PHPT, with many institutions using both methods in combination. The diagnostic performance of US and planar 99mTc-MIBI scintigraphy seems to be similar. The use of tomographic imaging (SPECT and SPECT/CT) increases the detection rate of HP compared to planar 99mTc-MIBI scintigraphy. Whereas traditional computed tomography (CT) has limited usefulness in PHPT, four dimensional CT (4D-CT) has similar diagnostic performance compared to tomographic parathyroid scintigraphy but a higher radiation dose. Although initial encouraging results, to date there is insufficient evidence to recommend the routine use of MRI or positron emission tomography (PET) with several radiopharmaceuticals in patients with PHPT. However, they could be useful alternatives in cases with negative or discordant findings at first-line imaging methods. Patients with PHPT who are candidates for parathyroidectomy should be referred to an expert clinician to decide which imaging studies to perform based on regional imaging capabilities. The imaging techniques with higher diagnostic performance in detecting and localizing HP seems to be 99mTc-MIBI SPECT/CT and 4D-CT. Taking into account several data beyond the diagnostic performance, the combination of cervical US performed by an experienced parathyroid sonographer and 99mTc-MIBI SPECT or SPECT//CT seems to be an optimal first-line strategy in the preoperative planning of patients with PHPT.

  17. Dose and diagnostic image quality in digital tomosynthesis imaging of facial bones in pediatrics

    NASA Astrophysics Data System (ADS)

    King, J. M.; Hickling, S.; Elbakri, I. A.; Reed, M.; Wrogemann, J.

    2011-03-01

    The purpose of this study was to evaluate the use of digital tomosynthesis (DT) for pediatric facial bone imaging. We compared the eye lens dose and diagnostic image quality of DT facial bone exams relative to digital radiography (DR) and computed tomography (CT), and investigated whether we could modify our current DT imaging protocol to reduce patient dose while maintaining sufficient diagnostic image quality. We measured the dose to the eye lens for all three modalities using high-sensitivity thermoluminescent dosimeters (TLDs) and an anthropomorphic skull phantom. To assess the diagnostic image quality of DT compared to the corresponding DR and CT images, we performed an observer study where the visibility of anatomical structures in the DT phantom images were rated on a four-point scale. We then acquired DT images at lower doses and had radiologists indicate whether the visibility of each structure was adequate for diagnostic purposes. For typical facial bone exams, we measured eye lens doses of 0.1-0.4 mGy for DR, 0.3-3.7 mGy for DT, and 26 mGy for CT. In general, facial bone structures were visualized better with DT then DR, and the majority of structures were visualized well enough to avoid the need for CT. DT imaging provides high quality diagnostic images of the facial bones while delivering significantly lower doses to the lens of the eye compared to CT. In addition, we found that by adjusting the imaging parameters, the DT effective dose can be reduced by up to 50% while maintaining sufficient image quality.

  18. Integration of CT urography improves diagnostic confidence of 68Ga-PSMA-11 PET/CT in prostate cancer patients.

    PubMed

    Will, Leon; Giesel, Frederik L; Freitag, Martin T; Berger, Anne K; Mier, Walter; Kopka, Klaus; Koerber, Stefan A; Rathke, Hendrik; Kremer, Christophe; Kratochwil, Clemens; Kauczor, Hans-Ulrich; Haberkorn, Uwe; Weber, Tim F

    2017-12-20

    To prove the feasibility of integrating CT urography (CTU) into 68 Ga-PSMA-11 PET/CT and to analyze the impact of CTU on assigning focal tracer accumulation in the ureteric space to either ureteric excretion or metastatic disease concerning topographic attribution and diagnostic confidence. Ten prostate cancer patients who underwent 68 Ga-PSMA-11 PET/CT including CTU because of biochemical relapse or known metastatic disease were retrospectively analyzed. CTU consisted of an excretory phase 10 min after injection of 80 mL iodinated contrast material. Ureter opacification at CTU was evaluated using the following score: 0, 0% opacification; 1, < 50%; 2, 50-99%; 3, 100%. Topographic attribution and confidence of topographic attribution of focal tracer accumulation in the ureteric space were separately assessed for 68 Ga-PSMA-11 PET/CT without and with CTU. Diagnostic confidence was evaluated using the following score: 0, < 25% confidence; 1, 26-50%; 2, 51-75%; 3, 76-100%. At CTU, mean ureter opacification score was 2.6 ± 0.7. At 68 Ga-PSMA-11 PET/CT without CTU, mean confidence of topographic attribution of focal tracer accumulation was 2.5 ± 0.7 in total and 2.6 ± 0.7 for metastatic disease. At 68 Ga-PSMA-11 PET/CT with CTU, mean confidence of topographic attribution of focal areas of tracer accumulation was significantly higher with 2.9 ± 0.2 in total and 2.7 ± 0.9 for metastatic disease (p < 0.001). In 4 of 34 findings (12%) attribution to either ureteric excretion or metastatic disease was discrepant between 68 Ga-PSMA-11 PET/CT without and with CTU (n.s). Integration of CTU into 68 Ga-PSMA-11 PET/CT is feasible and increases diagnostic confidence of assigning focal areas of tracer accumulation in the ureteric space to either metastatic disease or ureteric excretion.

  19. Piscine reovirus in wild and farmed salmonids in British Columbia, Canada: 1974-2013.

    PubMed

    Marty, G D; Morrison, D B; Bidulka, J; Joseph, T; Siah, A

    2015-08-01

    Piscine reovirus (PRV) was common among wild and farmed salmonids in British Columbia, western Canada, from 1987 to 2013. Salmonid tissues tested for PRV by real-time rRT-PCR included sections from archived paraffin blocks from 1974 to 2008 (n = 363) and fresh-frozen hearts from 2013 (n = 916). The earliest PRV-positive sample was from a wild-source steelhead trout, Oncorhynchus mykiss (Walbaum), from 1977. By histopathology (n = 404), no fish had lesions diagnostic for heart and skeletal muscle inflammation (HSMI). In some groups, lymphohistiocytic endocarditis affected a greater proportion of fish with PRV than fish without PRV, but the range of Ct values among affected fish was within the range of Ct values among unaffected fish. Also, fish with the lowest PRV Ct values (18.4-21.7) lacked endocarditis or any other consistent lesion. From 1987 to 1994, the proportion of PRV positives was not significantly different between farmed Atlantic salmon, Salmo salar L. (44% of 48), and wild-source salmonids (31% of 45). In 2013, the proportion of PRV positives was not significantly different between wild coho salmon, Oncorhynchus kisutch (Walbaum), sampled from British Columbia (5.0% of 60) or the reference region, Alaska, USA (10% of 58). © 2014 John Wiley & Sons Ltd.

  20. Use of 3×2 tables with an intention to diagnose approach to assess clinical performance of diagnostic tests: meta-analytical evaluation of coronary CT angiography studies

    PubMed Central

    Schuetz, Georg M; Schlattmann, Peter

    2012-01-01

    Objective To determine whether a 3×2 table, using an intention to diagnose approach, is better than the “classic” 2×2 table at handling transparent reporting and non-evaluable results, when assessing the accuracy of a diagnostic test. Design Based on a systematic search for diagnostic accuracy studies of coronary computed tomography (CT) angiography, full texts of relevant studies were evaluated to determine whether they could calculate an alternative 3×2 table. To quantify an overall effect, we pooled diagnostic accuracy values according to a meta-analytical approach. Data sources Medline (via PubMed), Embase (via Ovid), and ISI Web of Science electronic databases. Eligibility criteria Prospective English or German language studies comparing coronary CT with conventional coronary angiography in all patients and providing sufficient data for a patient level analysis. Results 120 studies (10 287 patients) were eligible. Studies varied greatly in their approaches to handling non-evaluable findings. We found 26 studies (including 2298 patients) that allowed us to calculate both 2×2 tables and 3×2 tables. Using a bivariate random effects model, we compared the 2×2 table with the 3×2 table, and found significant differences for pooled sensitivity (98.2 (95% confidence interval 96.7 to 99.1) v 92.7 (88.5 to 95.3)), area under the curve (0.99 (0.98 to 1.00) v 0.93 (0.91 to 0.95)), positive likelihood ratio (9.1 (6.2 to 13.3) v 4.4 (3.3 to 6.0)), and negative likelihood ratio (0.02 (0.01 to 0.04) v 0.09 (0.06 to 0.15); (P<0.05)). Conclusion Parameters for diagnostic performance significantly decrease if non-evaluable results are included by a 3×2 table for analysis (intention to diagnose approach). This approach provides a more realistic picture of the clinical potential of diagnostic tests. PMID:23097549

  1. Abdominal Pediatric Cancer Surveillance using Serial CT: Evaluation of Organ Absorbed Dose and Effective Dose

    PubMed Central

    Lam, Diana; Wootton-Gorges, Sandra L.; McGahan, John P.; Stern, Robin; Boone, John M.

    2012-01-01

    Computed tomography (CT) is used extensively in cancer diagnosis, staging, evaluation of response to treatment, and in active surveillance for cancer reoccurrence. A review of CT technology is provided, at a level of detail appropriate for a busy clinician to review. The basis of x-ray CT dosimetry is also discussed, and concepts of absorbed dose and effective dose are distinguished. Absorbed dose is a physical quantity (measured in milliGray) equal to the x-ray energy deposited in a mass of tissue, whereas effective dose utilizes an organ-specific weighting method which converts organ doses to effective dose measured in milliSieverts. The organ weighting values carry with them a measure of radiation risk, and so effective dose (in mSv) is not a physical dose metric but rather is one that conveys radiation risk. The use of CT in a cancer surveillance protocol was used as an example of a pediatric patient who had kidney cancer, with surgery and radiation therapy. The active use of CT for cancer surveillance along with diagnostic CT scans led to a total of 50 CT scans performed on this child in a 7 year period. It was estimated that the patient received an average organ dose of 431 mGy from these CT scans. By comparison, the radiation therapy was performed and delivered 50.4 Gy to the patient’s abdomen. Thus, the total dose from CT represented only 0.8% of the patients radiation dose. PMID:21362521

  2. Assessment of medial coronoid disease in 180 canine lame elbow joints: a sensitivity and specificity comparison of radiographic, computed tomographic and arthroscopic findings.

    PubMed

    Villamonte-Chevalier, A; van Bree, H; Broeckx, Bjg; Dingemanse, W; Soler, M; Van Ryssen, B; Gielen, I

    2015-09-25

    Diagnostic imaging is essential to assess the lame patient; lesions of the elbow joint have traditionally been evaluated radiographically, however computed tomography (CT) has been suggested as a useful technique to diagnose various elbow pathologies. The primary objective of this study was to determine the sensitivity and specificity of CT to assess medial coronoid disease (MCD), using arthroscopy as gold standard. The secondary objective was to ascertain the radiographic sensitivity and specificity for MCD compared with CT. For this study 180 elbow joints were assessed, of which 141 had been examined with radiography, CT and arthroscopy; and 39 joints, had radiographic and CT assessment. Sensitivity and specificity were calculated for CT and radiographic findings using available statistical software. Sensitivity and specificity of CT using arthroscopy as gold standard resulted in high values for sensitivity (100 %) and specificity (93 %) for the assessment of MCD. For the radiographic evaluation, a sensitivity of 98 % and specificity of 64 - 69 % using CT as the technique of reference, were found. These results suggest that in case of doubt during radiographic assessment, CT could be used as a non-invasive technique to assess the presence of MCD. Based on the high sensitivity and specificity obtained in this study it has been considered that CT, rather than arthroscopy, is the preferred noninvasive technique to assess MCD lesions of the canine elbow joint.

  3. Review of Extraskeletal Activity on Tc-99m Methylene Diphosphonate Bone Scintigraphy and Value of Cross-Sectional and SPECT-CT Imaging Correlation.

    PubMed

    Bermo, Mohammed; Behnia, Sanaz; Fair, Joanna; Miyaoka, Robert S; Elojeimy, Saeed

    2017-07-31

    Recognizing the different mechanisms and imaging appearance of extraskeletal Tc-99m methylene diphosphonate uptake enhances the diagnostic value of bone scan interpretation. In this article, we present a pictorial review of the different mechanisms of extraskeletal Tc-99m methylene diphosphonate uptake on bone scintigraphy including neoplastic, inflammatory, ischemic, traumatic, excretory, and iatrogenic. We also illustrate through case examples the added value of correlation with cross-sectional and single photon emission computed tomography and computed tomography imaging in localizing and characterizing challenging cases of extraskeletal uptake. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Novel use of ViewRay MRI guidance for high-dose-rate brachytherapy in the treatment of cervical cancer.

    PubMed

    Ko, Huaising C; Huang, Jessie Y; Miller, Jessica R; Das, Rupak K; Wallace, Charles R; De Costa, Anna-Maria A; Francis, David M; Straub, Margaret R; Anderson, Bethany M; Bradley, Kristin A

    To characterize image quality and feasibility of using ViewRay MRI (VR)-guided brachytherapy planning for cervical cancer. Cervical cancer patients receiving intracavitary brachytherapy with tandem and ovoids, planned using 0.35T VR MRI at our institution, were included in this series. The high-risk clinical target volume (HR-CTV), visible gross tumor volume, bladder, sigmoid, bowel, and rectum contours for each fraction of brachytherapy were evaluated for dosimetric parameters. Typically, five brachytherapy treatments were planned using the T2 sequence on diagnostic MRI for the first and third fractions, and a noncontrast true fast imaging with steady-state precession sequence on VR or CT scan for the remaining fractions. Most patients received 5.5 Gy × 5 fractions using high-dose-rate Ir-192 following 45 Gy of whole-pelvis radiotherapy. The plan was initiated at 5.5 Gy to point A and subsequently optimized and prescribed to the HR-CTV. The goal equivalent dose in 2 Gy fractions for the combined external beam and brachytherapy dose was 85 Gy. Soft-tissue visualization using contrast-to-noise ratios to distinguish normal tissues from tumor at their interface was compared between diagnostic MRI, CT, and VR. One hundred and forty-two fractions of intracavitary brachytherapy were performed from April 2015 to January 2017 on 29 cervical cancer patients, ranging from stages IB1 to IVA. The median HR-CTV was 27.78 cc, with median D 90 HR-CTV of 6.1 Gy. The median time from instrument placement to start of treatment using VR was 65 min (scan time 2 min), compared to 105 min using diagnostic MRI (scan time 11 min) (t-test, p < 0.01). The contrast-to-noise ratio of tumor to cervix in both diagnostic MRI and VR had significantly higher values compared to CT (ANOVA and t-tests, p < 0.01). We report the first clinical use of VR-guided brachytherapy. Time to treatment using this approach was shorter compared to diagnostic MRI. VR also provided significant advantage in visualizing the tumor and cervix compared to CT. This presents a feasible and reliable manner to image and plan gynecologic brachytherapy. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  5. Evaluation of a new imaging tool for use with major trauma cases in the emergency department.

    PubMed

    Crönlein, Moritz; Holzapfel, Konstantin; Beirer, Marc; Postl, Lukas; Kanz, Karl-Georg; Pförringer, Dominik; Huber-Wagner, Stefan; Biberthaler, Peter; Kirchhoff, Chlodwig

    2016-11-17

    The aim of this study was to evaluate potential benefits of a new diagnostic software prototype (Trauma Viewer, TV) automatically reformatting computed tomography (CT) data on diagnostic speed and quality, compared to CT-image data evaluation using a conventional CT console. Multiple trauma CT data sets were analysed by one expert radiology and one expert traumatology fellow independently twice, once using the TV and once using the secondary conventional CT console placed in the CT control room. Actual analysis time and precision of diagnoses assessment were evaluated. The TV and CT-console results were compared respectively, but also a comparison to the initial multiple trauma CT reports assessed by emergency radiology fellows considered as the gold standard was performed. Finally, design and function of the Trauma Viewer were evaluated in a descriptive manner. CT data sets of 30 multiple trauma patients were enrolled. Mean time needed for analysis of one CT dataset was 2.43 min using the CT console and 3.58 min using the TV respectively. Thus, secondary conventional CT console analysis was on average 1.15 min shorter compared to the TV analysis. Both readers missed a total of 11 diagnoses using the secondary conventional CT console compared to 12 missed diagnoses using the TV. However, none of these overlooked diagnoses resulted in an Abbreviated Injury Scale (AIS) > 2 corresponding to life threatening injuries. Even though it took the two expert fellows a little longer to analyse the CT scans on the prototype TV compared to the CT console, which can be explained by the new user interface of the TV, our preliminary results demonstrate that, after further development, the TV might serve as a new diagnostic feature in the trauma room management. Its high potential to improve time and quality of CT-based diagnoses might help in fast decision making regarding treatment of severely injured patients.

  6. A BMI-adjusted ultra-low-dose CT angiography protocol for the peripheral arteries-Image quality, diagnostic accuracy and radiation exposure.

    PubMed

    Schreiner, Markus M; Platzgummer, Hannes; Unterhumer, Sylvia; Weber, Michael; Mistelbauer, Gabriel; Loewe, Christian; Schernthaner, Ruediger E

    2017-08-01

    To investigate radiation exposure, objective image quality, and the diagnostic accuracy of a BMI-adjusted ultra-low-dose CT angiography (CTA) protocol for the assessment of peripheral arterial disease (PAD), with digital subtraction angiography (DSA) as the standard of reference. In this prospective, IRB-approved study, 40 PAD patients (30 male, mean age 72 years) underwent CTA on a dual-source CT scanner at 80kV tube voltage. The reference amplitude for tube current modulation was personalized based on the body mass index (BMI) with 120 mAs for [BMI≤25] or 150 mAs for [2570%) was assessed by two readers independently and compared to subsequent DSA. Radiation exposure was assessed with the computed tomography dose index (CTDIvol) and the dosis-length product (DLP). Objective image quality was assessed via contrast- and signal-to-noise ratio (CNR and SNR) measurements. Radiation exposure and image quality were compared between the BMI groups and between the BMI-adjusted ultra-low-dose protocol and the low-dose institutional standard protocol (ISP). The BMI-adjusted ultra-low-dose protocol reached high diagnostic accuracy values of 94% for Reader 1 and 93% for Reader 2. Moreover, in comparison to the ISP, it showed significantly (p<0.001) lower CTDIvol (1.97±0.55mGy vs. 4.18±0.62 mGy) and DLP (256±81mGy x cm vs. 544±83mGy x cm) but similar image quality (p=0.37 for CNR). Furthermore, image quality was similar between BMI groups (p=0.86 for CNR). A CT protocol that incorporates low kV settings with a personalized (BMI-adjusted) reference amplitude for tube current modulation and iterative reconstruction enables very low radiation exposure CTA, while maintaining good image quality and high diagnostic accuracy in the assessment of PAD. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Role of Combined 68Ga-DOTATOC and 18F-FDG Positron Emission Tomography/Computed Tomography in the Diagnostic Workup of Pancreas Neuroendocrine Tumors: Implications for Managing Surgical Decisions.

    PubMed

    Cingarlini, Sara; Ortolani, Silvia; Salgarello, Matteo; Butturini, Giovanni; Malpaga, Anna; Malfatti, Veronica; DʼOnofrio, Mirko; Davì, Maria Vittoria; Vallerio, Paola; Ruzzenente, Andrea; Capelli, Paola; Citton, Elia; Grego, Elisabetta; Trentin, Chiara; De Robertis, Riccardo; Scarpa, Aldo; Bassi, Claudio; Tortora, Giampaolo

    2017-01-01

    Ga-DOTATOC (Ga) positron emission tomography (PET)/computed tomography (CT) is recommended in the workup of pancreas neuroendocrine tumors (PanNETs); evidence suggests that F-FDG (F) PET/CT can also provide prognostic information. Aims of this study were to assess the role of combined Ga- and F-PET/CT in the evaluation of grade (G) 1-2 PanNETs and to test the correlation between F-PET/CT positivity and tumor grade. Preoperative Ga- and F-PET/CT of 35 patients with surgically resected G1-2 PanNETs were evaluated. For grading, the 2010 World Health Organization Classification was used; an ancillary analysis with Ki67 cutoffs at 5% to 20% was conducted. Correlation between F-PET/CT positivity (SUVmax > 3.5) and grade was assessed. Of 35 PanNETs, 28.6% and 71.4% were G1 and G2 as per World Health Organization. Ga-PET/CT showed high sensitivity (94.3%) in detecting G1-2 PanNETs. F-PET/CT was positive in 20% and 76% G1 and G2 tumors (P = 0.002). F-PET/CT identified G2 PanNETs with high positive predictive value (PPV, 90.5%). F-PET/CT correlated with tumor grade also in the ancillary analysis (P = 0.009). The high sensitivity of Ga-PET/CT in NET detection is known. The high PPV of F-PET/CT in the identification of G2 forms suggests its potential role in PanNETs prognostication and risk stratification.

  8. Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.

    PubMed

    Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M

    2016-12-01

    Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.

  9. Medical thoracoscopy vs CT scan-guided Abrams pleural needle biopsy for diagnosis of patients with pleural effusions: a randomized, controlled trial.

    PubMed

    Metintas, Muzaffer; Ak, Guntulu; Dundar, Emine; Yildirim, Huseyin; Ozkan, Ragip; Kurt, Emel; Erginel, Sinan; Alatas, Fusun; Metintas, Selma

    2010-06-01

    In cases of pleural effusion, tissue samples can be obtained through Abrams needle pleural biopsy (ANPB), thoracoscopy, or cutting-needle pleural biopsy under the guidance of CT scan (CT-CNPB) for histopathologic analysis. This study aimed to compare the diagnostic efficiency and reliability of ANPB under CT scan guidance (CT-ANPB) with that of medical thoracoscopy in patients with pleural effusion. Between January 2006 and January 2008, 124 patients with exudative pleural effusion that could not be diagnosed by cytologic analysis were included in the study. All patients were randomized after the CT scan was performed. Patients either underwent CT-ANPB or thoracoscopy. The two groups were compared in terms of diagnostic sensitivity and complications associated with the methods used. Of the 124 patients, malignant mesothelioma was diagnosed in 33, metastatic pleural disease in 47, benign pleural disease in 42, and two were of indeterminate origin. In the CT-ANPB group, the diagnostic sensitivity was 87.5%, as compared with 94.1% in the thoracoscopy group; the difference was not statistically significant (P = .252). No difference was identified between the sensitivities of the two methods based on the cause, the CT scan findings, and the degree of pleural thickening. Complication rates were low and acceptable. We recommend the use of CT-ANPB as the primary method of diagnosis in patients with pleural thickening or lesions observed by CT scan. In patients with only pleural fluid appearance on CT scan and in those who may have benign pleural pathologies other than TB, the primary method of diagnosis should be medical thoracoscopy. clinicaltrials.gov; Identifier: NCT00720954.

  10. Metabolic Tumor Volume on 18F-FDG PET/CT Improves Preoperative Identification of High-Risk Endometrial Carcinoma Patients.

    PubMed

    Husby, Jenny A; Reitan, Bernt C; Biermann, Martin; Trovik, Jone; Bjørge, Line; Magnussen, Inger J; Salvesen, Øyvind O; Salvesen, Helga B; Haldorsen, Ingfrid S

    2015-08-01

    Our objective was to prospectively explore the diagnostic value of (18)F-FDG PET/CT for preoperative staging in endometrial carcinomas and to investigate whether (18)F-FDG PET-specific quantitative tumor parameters reflect clinical and histologic characteristics. Preoperative (18)F-FDG PET/CT was prospectively performed on 129 consecutive endometrial carcinoma patients. Two physicians who did not know the clinical findings or staging results independently reviewed the images, assessing primary tumor, cervical stroma involvement and metastatic spread, and determining maximum and mean standardized uptake value (SUVmax and SUVmean, respectively) for tumor, metabolic tumor volume (MTV), and total lesion glycolysis (TLG). All parameters were analyzed in relation to histomorphologic and clinical tumor characteristics. Receiver-operating-characteristic curves for identification of deep myometrial invasion and lymph node metastases were generated, and MTV cutoffs for predicting deep myometrial invasion and lymph node metastases were calculated. The sensitivity, specificity, and accuracy of (18)F-FDG PET/CT for the detection of lymph node metastases were 77%-85%, 91%-96%, and 89%-93%, respectively. SUVmax, SUVmean, MTV, and TLG were significantly related to deep myometrial invasion, presence of lymph node metastases, and high histologic grade (P < 0.015 for all) and independently predicted deep myometrial invasion (P < 0.015) and lymph node metastases (P < 0.025) after adjustment for preoperative histologic risk (based on subtype and grade) in endometrial biopsies. Optimal cutoffs for MTV in predicting deep myometrial invasion (20 mL) and the presence of lymph node metastases (30 mL) yielded odds ratios of 7.8 (P < 0.001) and 16.5 (P = 0.001), respectively. (18)F-FDG PET/CT represents a clinically valuable tool for preoperatively evaluating the presence of lymph node metastases in endometrial carcinoma patients. Applying MTV cutoffs for the prediction of deep myometrial invasion and lymph node metastases may increase diagnostic accuracy and aid preoperative identification of high-risk patients, enabling restriction of lymphadenectomy for patients with a low risk of aggressive disease. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  11. Comparison of the Canadian CT head rule and the New Orleans criteria in patients with minor head injury in a Spanish hospital.

    PubMed

    Valle Alonso, Joaquín; Fonseca Del Pozo, Francisco Javier; Vaquero Álvarez, Manuel; Lopera Lopera, Elisa; Garcia Segura, Marisol; García Arévalo, Ricardo

    2016-12-16

    To compare two scales for assessment of patients with mild head injury. The Canadian CT Head Rule (CCHR) and New Orleans Criteria (NOC) according to their diagnostic accuracy in patients attending an emergency department, and to determine the most important predictive values. Cross-sectional study in a first-level Hospital in the period of January 2011 to January 2013. Patients with mild head injury criteria were included. All the patients underwent a computed tomography (CT) of the head as part of internal protocol and the CCHR and NOC criteria were recorded for each patient. We consider the main variable the presence of traumatic lesions on CT and, as secondary variables, neurosurgical intervention and post-concussion syndrome. Sensitivity, specificity, predictive values and validity index (VI) of the CCHR and the NO criteria in the subgroup of patients with a Glasgow Coma Scale (GCS) score of 15 points were compared. A total of 217 patients, of whom 197 had a GCS score of 15 points were evaluated. Both rules showed 100% sensitivity when a significant injury was presented in the CT, the CCHR 100% (95% CI: 97.4%-100%) and the NO criteria 100% (95% CI: 97.4%-100%); but the CCHR achieved higher values of specificity 25.3% (95% CI: 18.6%-32%), positive predictive value (PPV) and VI. The two rules showed a 100% sensitivity regarding neurosurgical intervention; however the CCHR with high-risk criteria showed better specificity, PPV and VI 55.2 (95% CI: 8.3%-62.2%) compared to the NO criteria 7.6 (95% CI: 3.8%-11.5%). With regard to post-concussion syndrome criteria NO criteria showed better sensitivity 100% (95% CI: 96.2%-100%) and predictive values, but lower specificity and VI compared with the CCHR 76.9% (95% CI: 50.2%-100%). Our study demonstrates the high sensitivity of the CCHR and the NO criteria in patients with mild head injury, both to detect a significant clinical lesion on CT or the need for neurosurgical intervention and better specificity of CCHR compared with NO criteria. The adoption of clinical prediction rules, especially the CCHR, to request a CT scan in patients with mild head injury should be recommended in the emergency department. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  12. Accuracy and cost-effectiveness of dynamic contrast-enhanced CT in the characterisation of solitary pulmonary nodules-the SPUtNIk study.

    PubMed

    Qureshi, N R; Rintoul, R C; Miles, K A; George, S; Harris, S; Madden, J; Cozens, K; Little, L A; Eichhorst, K; Jones, J; Moate, P; McClement, C; Pike, L; Sinclair, D; Wong, W L; Shekhdar, J; Eaton, R; Shah, A; Brindle, L; Peebles, C; Banerjee, A; Dizdarevic, S; Han, S; Poon, F W; Groves, A M; Kurban, L; Frew, A J; Callister, M E; Crosbie, P; Gleeson, F V; Karunasaagarar, K; Kankam, O; Gilbert, F J

    2016-01-01

    Solitary pulmonary nodules (SPNs) are common on CT. The most cost-effective investigation algorithm is still to be determined. Dynamic contrast-enhanced CT (DCE-CT) is an established diagnostic test not widely available in the UK currently. The SPUtNIk study will assess the diagnostic accuracy, clinical utility and cost-effectiveness of DCE-CT, alongside the current CT and 18-flurodeoxyglucose-positron emission tomography) ( 18 FDG-PET)-CT nodule characterisation strategies in the National Health Service (NHS). Image acquisition and data analysis for 18 FDG-PET-CT and DCE-CT will follow a standardised protocol with central review of 10% to ensure quality assurance. Decision analytic modelling will assess the likely costs and health outcomes resulting from incorporation of DCE-CT into management strategies for patients with SPNs. Approval has been granted by the South West Research Ethics Committee. Ethics reference number 12/SW/0206. The results of the trial will be presented at national and international meetings and published in an Health Technology Assessment (HTA) Monograph and in peer-reviewed journals. ISRCTN30784948; Pre-results.

  13. The bone scan.

    PubMed

    Brenner, Arnold I; Koshy, June; Morey, Jose; Lin, Cheryl; DiPoce, Jason

    2012-01-01

    Bone imaging continues to be the second greatest-volume nuclear imaging procedure, offering the advantage of total body examination, low cost, and high sensitivity. Its power rests in the physiological uptake and pathophysiologic behavior of 99m technetium (99m-Tc) diphosphonates. The diagnostic utility, sensitivity, specificity, and predictive value of 99m-Tc bone imaging for benign conditions and tumors was established when only planar imaging was available. Currently, nearly all bone scans are performed as a planar study (whole-body, 3-phase, or regional), with the radiologist often adding single-photon emission computed tomography (SPECT) imaging. Here we review many current indications for planar bone imaging, highlighting indications in which the planar data are often diagnostically sufficient, although diagnosis may be enhanced by SPECT. (18)F sodium fluoride positron emission tomography (PET) is also re-emerging as a bone agent, and had been considered interchangeable with 99m-Tc diphosphonates in the past. In addition to SPECT, new imaging modalities, including (18)F fluorodeoxyglucose, PET/CT, CT, magnetic resonance, and SPECT/CT, have been developed and can aid in evaluating benign and malignant bone disease. Because (18)F fluorodeoxyglucose is taken up by tumor cells and Tc diphosphonates are taken up in osteoblastic activity or osteoblastic healing reaction, both modalities are complementary. CT and magnetic resonance may supplement, but do not replace, bone imaging, which often detects pathology before anatomic changes are appreciated. We also stress the importance of dose reduction by reducing the dose of 99m-Tc diphosphonates and avoiding unnecessary CT acquisitions. In addition, we describe an approach to image interpretation that emphasizes communication with referring colleagues and correlation with appropriate history to significantly improve our impact on patient care. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. [18F]Fluorocholine PET/CT Imaging of Liver Cancer: Radiopathologic Correlation with Tissue Phospholipid Profiling.

    PubMed

    Kwee, Sandi A; Sato, Miles M; Kuang, Yu; Franke, Adrian; Custer, Laurie; Miyazaki, Kyle; Wong, Linda L

    2017-06-01

    [ 18 F]fluorocholine PET/CT can detect hepatocellular carcinoma (HCC) based on imaging the initial steps of phosphatidylcholine synthesis. To relate the diagnostic performance of [ 18 F]fluorocholine positron emission tomography (PET)/x-ray computed tomography (CT) to the phospholipid composition of liver tumors, radiopathologic correspondence was performed in patients with early-stage liver cancer who had undergone [ 18 F]fluorocholine PET/CT before tumor resection. Tumor and adjacent liver were profiled by liquid chromatography mass spectrometry, quantifying phosphatidylcholine species by mass-to-charge ratio. For clinical-radiopathologic correlation, HCC profiles were reduced to two orthogonal principal component factors (PCF1 and PCF2) accounting for 80 % of total profile variation. Tissues from 31 HCC patients and 4 intrahepatic cholangiocarcinoma (ICC) patients were analyzed, revealing significantly higher levels of phosphocholine, CDP-choline, and highly saturated phosphatidylcholine species in HCC tumors relative to adjacent liver and ICC tumors. Significant loading values for PCF1 corresponded to phosphatidylcholines containing poly-unsaturated fatty acids while PCF2 corresponded only to highly saturated phosphatidylcholines. Only PCF2 correlated significantly with HCC tumor-to-liver [ 18 F]fluorocholine uptake ratio (ρ = 0.59, p < 0.0005). Sensitivity for all tumors based on an abnormal [ 18 F]fluorocholine uptake ratio was 93 % while sensitivity for HCC based on increased tumor [ 18 F]fluorocholine uptake was 84 %, with lower levels of highly saturated phosphatidylcholines in tumors showing low [ 18 F]fluorocholine uptake. Most HCC tumors contain high levels of saturated phosphatidylcholines, supporting their dependence on de novo fatty acid metabolism for phospholipid membrane synthesis. While [ 18 F]fluorocholine PET/CT can serve to identify these lipogenic tumors, its imperfect diagnostic sensitivity implies metabolic heterogeneity across HCC and a weaker lipogenic phenotype in some tumors.

  15. [The diagnostic value of dual-energy CT and 3 Tesla MRI in the diagnosis of German Mardi Gras donuts--where is the mustard, where is the custard and where is the jam?].

    PubMed

    Morhard, D; Dietrich, O; Reiser, M; Ertl-Wagner, B

    2008-04-01

    As a Mardi Gras joke, the original jam or custard fillings of German Mardi Gras donuts are frequently replaced with mustard which cannot be identified on the outside of the donut. The aim of our study was to evaluate the impact of modern CT and MRI techniques on the diagnostic evaluation of donuts filled with mustard, jam or custard. 4 commercially available donuts were included in the study. One was filled with custard (PK) and one with jam (MK). Two donuts were specifically prepared and filled with Bavarian mustard (SK1) or extra-hot (SK2) mustard. 3 Tesla MRI was performed with T 2- and T 1-weighted STIR, diffusion and susceptibility-weighted (SWI) sequences. In addition, the donuts underwent dual-energy CT. PK was able to be easily differentiated from the other donuts due to its hyperintensity in the STIR sequences and hypointensity in the T 1-weighted sequences. MK was able to be differentiated from S 1K and S 2K on the basis of its diffusion properties. S 1K demonstrated a pronounced heterogeneity of its matrix, especially in SWI. In CT, PK showed a pronounced hypoattenuation with negative Hounsfield units in contrast to the strongly hyperdense MK, S 1K and S 2K. S 1K and S 2K demonstrated X-ray attenuation considerably dependent on the X-ray energy. Donuts filled with jam, custard or mustard can be readily differentiated by modern MRI and CT techniques. Therefore, eating a mustard-filled donut can be reliably avoided.

  16. [18F]fluorocholine PET/CT imaging of liver cancer: radiopathologic correlation with tissue phospholipid profiling

    PubMed Central

    Kwee, Sandi A; Sato, Miles M; Kuang, Yu; Franke, Adrian; Custer, Laurie; Miyazaki, Kyle; Wong, Linda L

    2017-01-01

    BACKGROUND [18F]fluorocholine PET/CT can detect hepatocellular carcinoma (HCC) based on imaging the initial steps of phosphatidylcholine synthesis. To relate the diagnostic performance of [18F]fluorocholine PET/CT to the phospholipid composition of liver tumors, radiopathologic correspondence was performed in patients with early-stage liver cancer who had undergone [18F]fluorocholine PET/CT before tumor resection. METHODS Tumor and adjacent liver were profiled by liquid chromatography mass spectrometry, quantifying phosphatidylcholine species by mass-to-charge ratio. For clinical-radiopathologic correlation, HCC profiles were reduced to two orthogonal principal component factors (PCF1 and PCF2) accounting for 80% of total profile variation. RESULTS Tissues from 31 HCC patients and 4 intrahepatic cholangiocarcinoma (ICC) patients were analyzed, revealing significantly higher levels of phosphocholine, CDP-choline, and highly-saturated phosphatidylcholine species in HCC tumors relative to adjacent liver and ICC tumors. Significant loading values for PCF1 corresponded to phosphatidylcholines containing poly-unsaturated fatty acids while PCF2 corresponded only to highly-saturated phosphatidylcholines. Only PCF2 correlated significantly with HCC tumor-to-liver [18F]fluorocholine uptake ratio (ρ = 0.59, p < 0.0005). Sensitivity for all tumors based on an abnormal [18F]fluorocholine uptake ratio was 93%, while sensitivity for HCC based on increased tumor [18F]fluorocholine uptake was 84%, with lower levels of highly-saturated phosphatidylcholines in tumors showing low [18F]fluorocholine uptake. CONCLUSION Most HCC tumors contain high levels of saturated phosphatidylcholines, supporting their dependence on de-novo fatty acid metabolism for phospholipid membrane synthesis. While [18F]fluorocholine PET/CT can serve to identify these lipogenic tumors, its imperfect diagnostic sensitivity implies metabolic heterogeneity across HCC and a weaker lipogenic phenotype in some tumors. PMID:27787742

  17. FDG-PET, CT, MRI for diagnosis of local residual or recurrent nasopharyngeal carcinoma, which one is the best? A systematic review.

    PubMed

    Liu, Tao; Xu, Wen; Yan, Wei-Li; Ye, Ming; Bai, Yong-Rui; Huang, Gang

    2007-12-01

    To perform a systematic review to compare FDG-PET, CT, and MRI imaging for diagnosis of local residual or recurrent nasopharyngeal carcinoma. MEDLINE, EMBASE, the CBMdisc databases and some other databases were searched for relevant original articles published from January 1990 to June 2007. Inclusion criteria were as follows: Articles were reported in English or Chinese; FDG-PET, CT, or MRI was used to detect local residual or recurrent nasopharyngeal carcinoma; histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months were the reference standard. Two reviewers independently extracted data. A software called "Meta-DiSc" was used to obtain pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the Q* index. Twenty-one articles fulfilled all inclusion criteria. The pooled sensitivity estimates for PET (95%) were significantly higher than CT (76%) (P<0.001) and MRI (78%) (P<0.001). The pooled specificity estimates for PET (90%) were significantly higher than CT (59%) (P<0.001) and MRI (76%) (P<0.001). The pooled DOR estimates for PET (96.51) were significantly higher than CT (7.01) (P<0.001) and MRI (8.68) (P<0.001). SROC curve for FDG-PET showed better diagnostic accuracy than CT and MRI. The Q* index for PET (0.92) was significantly higher than CT (0.72) (P<0.001) and MRI (0.76) (P<0.01). For PET, the sensitivity and diagnostic OR for using qualitative analysis were significantly higher than using both qualitative and quantitative analyses (P<0.01). For CT, the sensitivity, specificity, diagnostic OR, and the Q* index for dual-section helical and multi-section helical were all significantly higher than nonhelical and single-section helical (P<0.01). And the sensitivity for 'section thickness <5 mm' was significantly lower than ' =5 mm' (P<0.01), while the specificity was significantly higher (P<0.01). For MRI, there were no significant differences found between magnetic field strength <1.5 and > or =1.5 T (P>0.05). FDG-PET was the best modality for diagnosis of local residual or recurrent nasopharyngeal carcinoma. The type of analysis for PET imaging and the section thickness for CT would affect the diagnostic results. Dual-section helical and multi-section helical CT were better than nonhelical and single-section helical CT.

  18. Quality of routine diagnostic abdominal images generated from a novel detector-based spectral CT scanner: a technical report on a phantom and clinical study.

    PubMed

    Hojjati, Mojgan; Van Hedent, Steven; Rassouli, Negin; Tatsuoka, Curtis; Jordan, David; Dhanantwari, Amar; Rajiah, Prabhakar

    2017-11-01

    To evaluate the image quality of routine diagnostic images generated from a novel detector-based spectral detector CT (SDCT) and compare it with CT images obtained from a conventional scanner with an energy-integrating detector (Brilliance iCT), Routine diagnostic (conventional/polyenergetic) images are non-material-specific images that resemble single-energy images obtained at the same radiation, METHODS: ACR guideline-based phantom evaluations were performed on both SDCT and iCT for CT adult body protocol. Retrospective analysis was performed on 50 abdominal CT scans from each scanner. Identical ROIs were placed at multiple locations in the abdomen and attenuation, noise, SNR, and CNR were measured. Subjective image quality analysis on a 5-point Likert scale was performed by 2 readers for enhancement, noise, and image quality. On phantom studies, SDCT images met the ACR requirements for CT number and deviation, CNR and effective radiation dose. In patients, the qualitative scores were significantly higher for the SDCT than the iCT, including enhancement (4.79 ± 0.38 vs. 4.60 ± 0.51, p = 0.005), noise (4.63 ± 0.42 vs. 4.29 ± 0.50, p = 0.000), and quality (4.85 ± 0.32, vs. 4.57 ± 0.50, p = 0.000). The SNR was higher in SDCT than iCT for liver (7.4 ± 4.2 vs. 7.2 ± 5.3, p = 0.662), spleen (8.6 ± 4.1 vs. 7.4 ± 3.5, p = 0.152), kidney (11.1 ± 6.3 vs. 8.7 ± 5.0, p = 0.033), pancreas (6.90 ± 3.45 vs 6.11 ± 2.64, p = 0.303), aorta (14.2 ± 6.2 vs. 11.0 ± 4.9, p = 0.007), but was slightly lower in lumbar-vertebra (7.7 ± 4.2 vs. 7.8 ± 4.5, p = 0.937). The CNR of the SDCT was also higher than iCT for all abdominal organs. Image quality of routine diagnostic images from the SDCT is comparable to images of a conventional CT scanner with energy-integrating detectors, making it suitable for diagnostic purposes.

  19. Variation in diagnostic performance among radiologists at screening CT colonography.

    PubMed

    Pooler, B Dustin; Kim, David H; Hassan, Cesare; Rinaldi, Antonio; Burnside, Elizabeth S; Pickhardt, Perry J

    2013-07-01

    To assess the variation in diagnostic performance among radiologists at screening computed tomographic (CT) colonography. In this HIPAA-compliant, institutional review board-approved study, 6866 asymptomatic adults underwent first-time CT colonographic screening at a single center between January 2005 and November 2011. Results of examinations were interpreted by one of eight board-certified abdominal radiologists (mean number of CT colonographic studies per reader, 858; range, 131-2202). Findings at CT colonography and subsequent colonoscopy were recorded, and key measures of diagnostic performance, including adenoma and advanced neoplasia detection rate, were compared among the radiologists. The overall prevalence of histopathologically confirmed advanced neoplasia was 3.6% and did not differ significantly among radiologists (range, 2.4%-4.4%; P = .067; P = .395 when one outlier was excluded). Overall, 19.5% of polyps detected at CT colonography proved to be advanced neoplasia and did not differ significantly among radiologists (range, 14.4%-23.2%; P = .223). The overall per-polyp endoscopic confirmation rate was 93.5%, ranging from 80.0% to 97.6% among radiologists (P = .585). The overall percentage of nondiagnostic CT colonographic examinations was 0.7% and was consistent among radiologists (range, 0.3%-1.1%; P = .509). Consistent performance for adenoma and advanced neoplasia detection, as well as other clinically relevant end points, were observed among radiologists at CT colonographic screening.

  20. High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium

    PubMed Central

    Feng, Ruiqi; Tong, Jiajie; Liu, Xiaofei; Zhao, Yu

    2017-01-01

    Objective To evaluate the feasibility and image quality (IQ) of prospectively high-pitch coronary CT angiography (CCTA) with low contrast medium injection rate at 70 kVp. Materials and Methods One hundred and four patients with suspected coronary artery disease (body mass index < 26 kg/m2, sinus rhythm and heart rate < 70 beats/min) were prospectively enrolled and randomly divided into two groups. In group A and group B, 28 mL and 40 mL of 370 mgI/mL iodinated contrast media was administrated at a flow rate of 3.5 and 5 mL/s, respectively. CT values, noise, signal-to-noise ratio, contrast-to-noise ratio (CNR) of the proximal segments of coronary arteries and subjective IQ were evaluated. Results The CT values and noise in group A were significantly lower than those in group B (434–485 Hounsfield units [HU] vs. 772–851 HU, all p < 0.001; 17.8–22.3 vs. 23.3–26.4, all p < 0.005). The CNRs of the right coronary artery and left main artery showed no statistical difference between the two groups (42.1 ± 13.8 vs. 36.8 ± 16.0, p = 0.074; 38.7 ± 10.6 vs. 38.1 ± 17.0, p = 0.819). No statistical difference was observed between the two groups in IQ scores (3.04 ± 0.75 vs. 3.0 ± 0.79, p = 0.526) and diagnostic ratio (96.1% [50/52] vs. 94.2% [49/52], p = 0.647). Conclusion Prospective high-pitch CCTA at 70 kVp with 28 mL of contrast media and injection rate of 3.5 mL/s could provide diagnostic IQ for normal-weight patients with heart rate of < 70 beats/min. PMID:28860894

  1. Malignant pleural disease: diagnosis by using diffusion-weighted and dynamic contrast-enhanced MR imaging--initial experience.

    PubMed

    Coolen, Johan; De Keyzer, Frederik; Nafteux, Philippe; De Wever, Walter; Dooms, Christophe; Vansteenkiste, Johan; Roebben, Ilse; Verbeken, Eric; De Leyn, Paul; Van Raemdonck, Dirk; Nackaerts, Kristiaan; Dymarkowski, Steven; Verschakelen, Johny

    2012-06-01

    To investigate the use of diffusion-weighted (DW) imaging for differentiating benign lesions from malignant pleural disease (MPD) and to retrospectively assess dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging acquisitions to find out whether combining these measurements with DW imaging could improve the diagnostic value of DW imaging. This study was approved by the local ethics committee, and all patients provided written informed consent. Thirty-one consecutive patients with pleural abnormalities suspicious for MPD underwent whole-body positron emission tomography (PET)/computed tomography (CT) and thorax MR examinations. Diagnostic thoracoscopy with histopathologic analysis of pleural biopsies served as the reference standard. First-line evaluation of each suspicious lesion was performed by using the apparent diffusion coefficient (ADC) calculated from the DW image, and the optimal cutoff value was found by using receiver operating characteristic curve analysis. Afterward, DCE MR imaging data were used to improve the diagnosis in the range of ADCs where DW imaging results were equivocal. Sensitivity, specificity, and accuracy of PET/CT for diagnosis of MPD were 100%, 35.3%, and 64.5%. The optimal ADC threshold to differentiate benign lesions from MPD with DW MR imaging was 1.52 × 10(-3) mm(2)/sec, with sensitivity, specificity, and accuracy of 71.4%, 100%, and 87.1%, respectively. This result could be improved to 92.8%, 94.1%, and 93.5%, respectively, when DCE MR imaging data were included in those cases where ADC was between 1.52 and 2.00 × 10(-3) mm(2)/sec. A total of 20 patients had disease diagnosed correctly, nine had disease diagnosed incorrectly, and two cases were undetermined with PET/CT. DW imaging helped stage disease correctly in 27 patients and incorrectly in four. The undetermined cases at PET/CT were correctly diagnosed at MR imaging. DW imaging is a promising tool for differentiating MPD from benign lesions, with high accuracy, and supplementation with DCE MR imaging seems to further improve sensitivity.

  2. Role of 18F-FDG PET/CT in diagnosing peritoneal carcinomatosis in the restaging of patient with ovarian cancer as compared to contrast enhanced CT and tumor marker Ca-125.

    PubMed

    Rubini, G; Altini, C; Notaristefano, A; Merenda, N; Rubini, D; Ianora, A A Stabile; Asabella, A Niccoli

    2014-01-01

    To investigate the role of whole-body fluorine-18-2-deoxy-2-fluoro-d-glucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in the identification of peritoneal carcinomatosis in patients with ovarian cancer (OC). Seventy-nine patients with histologically proven stages III-IV OC who underwent (18)F-FDG PET/CT were studied retrospectively. We considered group A as 51 patients who also underwent computed-tomography with contrast-enhancement (CECT), and group B as 35 patients who had also been tested for biomarker Ca-125. Sensitivity, specificity, accuracy, positive predictive values (PPV) and negative predictive values (NPV) of (18)F-FDG PET/CT as compared to CECT and to Ca-125 were evaluated. (18)F-FDG PET/CT' sensitivity, specificity, accuracy, PPV and NPV for all 79 patients were: 85%, 92.31%, 88.61%, 91.89% and 85.71%, respectively. (18)F-FDG PET/CT sensitivity in group A was 78.6%, while it was 53.6% for CECT. (18)F-FDG PET/CT specificity, calculated in the same group, was 91.3%, while that of CECT was 60.9% (statistically significant difference, McNemar 4, P=0.039). Accuracy was 84.3% and 56.9%, respectively. (18)F-FDG PET/CT' sensitivity in group B was 86.4%, while that of Ca-125 was 81.8% (no statistical difference, McNemar 0, P=1). (18)F-FDG PET/CT specificity in group B was 84.6% while that of Ca-125 was 38.5% (clear but not statistically significant difference, McNemar 3.12, P=0.070). Accuracy calculated in the same group was 85.7% for (18)F-FDG PET/CT and 65.7% for Ca-125. (18)F-FDG PET/CT is a useful diagnostic tool when peritoneal biopsy cannot be performed and it can better select those who are candidates for adjuvant chemotherapy. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  3. 18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.

    PubMed

    Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S

    2017-02-01

    This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.

  4. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations.

    PubMed

    Montes, Carlos; Tamayo, Pilar; Hernandez, Jorge; Gomez-Caminero, Felipe; García, Sofia; Martín, Carlos; Rosero, Angela

    2013-08-01

    Hybrid imaging, such as SPECT/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose.

  5. (11)C-Choline PET/CT for restaging prostate cancer. Results from 4,426 scans in a single-centre patient series.

    PubMed

    Graziani, Tiziano; Ceci, Francesco; Castellucci, Paolo; Polverari, Giulia; Lima, Giacomo Maria; Lodi, Filippo; Morganti, Alessio Giuseppe; Ardizzoni, Andrea; Schiavina, Riccardo; Fanti, Stefano

    2016-10-01

    To evaluate (11)C-choline PET/CT as a diagnostic tool for restaging prostate cancer (PCa), in a large, homogeneous and clinically relevant population of patients with biochemical recurrence (BCR) of PCa after primary therapy. The secondary aim was to assess the best timing for performing (11)C-choline PET/CT during BCR. We retrospectively analysed 9,632 (11)C-choline PET/CT scans performed in our institution for restaging PCa from January 2007 to June 2015. The inclusion criteria were: (1) proven PCa radically treated with radical prostatectomy (RP) or with primary external beam radiotherapy (EBRT); (2) PSA serum values available; (3) proven BCR (PSA >0.2 ng/mL after RP or PSA >2 ng/mL above the nadir after primary EBRT with rising PSA levels). Finally, 3,203 patients with recurrent PCa matching all the inclusion criteria were retrospectively enrolled and 4,426 scans were analysed. Overall, 52.8 % of the (11)C-choline PET/CT scans (2,337/4,426) and 54.8 % of the patients (1,755/3,203) were positive. In 29.4 % of the scans, at least one distant finding was observed. The mean and median PSA values were, respectively, 4.9 and 2.1 ng/mL at the time of the scan (range 0.2 - 50 ng/mL). In our series, 995 scans were performed in patients with PSA levels between 1 and 2 ng/mL. In this subpopulation the positivity rate in the 995 scans was 44.7 %, with an incidence of distant findings of 19.2 % and an incidence of oligometastatic disease (one to three lesions) of 37.7 %. The absolute PSA value at the time of the scan and ongoing androgen deprivation therapy were associated with an increased probability of a positive (11)C-choline PET/CT scan (p < 0.0001). In the ROC analysis, a PSA value of 1.16 ng/mL was the optimal cut-off value. In patients with a PSA value <1.16 ng/mL, 26.8 % of 1,426 (11)C-choline PET/CT scans were positive, with oligometastatic disease in 84.7 % of positive scans. In a large cohort of patients, the feasibility of (11)C-choline PET/CT for detecting the sites of metastatic disease in PCa patients with BCR was confirmed. The PSA level was the main predictor of a positive scan with 1.16 ng/mL as the optimal cut-off value. In the majority of positive scans oligometastatic disease, potentially treatable with salvage therapies, was observed.

  6. Is radiography justified for the evaluation of patients presenting with cervical spine trauma?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Theocharopoulos, Nicholas; Chatzakis, Georgios; Damilakis, John

    2009-10-15

    Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributablemore » risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional radiogenic lethal cancer incidents. According to the decision model calculations, the use of CT is more favorable over the use of radiography alone or radiography with CT by a factor of 13, for low risk 20 yr old patients, to a factor of 23, for high risk patients younger than 80 yr old. The radiography/CT imaging strategy slightly outperforms plain radiography for high and moderate risk patients. Regardless of the patient age, sex, and fracture risk, the higher diagnostic accuracy obtained by the CT examination counterbalances the increase in dose compared to plain radiography or radiography followed by CT only for positive radiographs and renders CT utilization justified and the radiographic screening redundant.« less

  7. PET/CT with 18F-choline: Physiological whole bio-distribution in male and female subjects and diagnostic pitfalls on 1000 prostate cancer patients: 18F-choline PET/CT bio-distribution and pitfalls. A southern Italian experience.

    PubMed

    Calabria, Ferdinando; Chiaravalloti, Agostino; Cicciò, Carmelo; Gangemi, Vincenzo; Gullà, Domenico; Rocca, Federico; Gallo, Gianpasquale; Cascini, Giuseppe Lucio; Schillaci, Orazio

    2017-08-01

    The 11 C/ 18 F-choline is a PET/CT radiopharmaceutical useful in detecting tumors with high lipogenesis. 11 C/ 18 F-choline uptake can occur in physiological conditions or tumors. The knowledge of its bio-distribution is essential to recognize physiologic variants or diagnostic pitfalls. Moreover, few information are available on the bio-distribution of this tracer in female patients. Our aim was to discuss some documented 18 F-choline PET/CT pitfalls in prostate cancer patients. Our secondary aim was to describe the 18 F-choline bio-distribution in the female body. We collected diagnostic pitfalls in three PET centers examining 1000 prostate cancer by 18 F-choline PET/CT. All pitfalls were ensured by follow-up, imaging and/or histology. We also performed whole body 18 F-choline PET/CT in 5 female patients. 169/1000 (16.9%) patients showed pitfalls not owing to prostate cancer. These findings were due to inflammation, benign tumors while, in 1% of examined patients, a concomitant neoplasm was found. In the female body, the breast showed low physiological uptake. The accurate knowledge of 18 F-choline PET/CT bio-distribution and diagnostic pitfalls is essential. Correlative imaging and histological exam are often necessary to depict pitfalls. In women, the uptake in the breast is due to the physiological gradient of 18 F-choline uptake in the exocrine glands. Our results confirm the possibility of 18 F-choline uptake in several diseases other than prostate cancer. However, our experience was acquired on a large population and shows that a conspicuous amount of 18 F-choline diagnostic pitfalls are easily recognizable and attributable to inflammation. A new advance in knowledge is the minimal difference in terms of physiological tracer bio-distribution between male and female patients. The knowledge of the physiological bio-distribution and of the potential pitfalls linked of a tracer could help physicians to choose the best diagnostic and therapeutic approaches for a better patient quality of life. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Utilization of head CT during injury visits to United States emergency departments: 2012-2015.

    PubMed

    Yun, Brian J; Borczuk, Pierre; Zachrison, Kori S; Goldstein, Joshua N; Berlyand, Yosef; Raja, Ali S

    2018-05-18

    Studies have shown increasing utilization of head computed tomography (CT) imaging of emergency department (ED) patients presenting with an injury-related visit. Multiple initiatives, including the Choosing Wisely™ campaign and evidence-based clinical decision support based on validated decision rules, have targeted head CT use in patients with injuries. Therefore, we investigated national trends in the use of head CT during injury-related ED visits from 2012 to 2015. This was a secondary analysis of data from the annual United States (U.S.) National Hospital Ambulatory Medical Care Survey from 2012 to 2015. The study population was defined as injury-related ED visits, and we sought to determine the percentage in which a head CT was ordered and, secondarily, to determine both the diagnostic yield of clinically significant intracranial findings and hospital characteristics associated with increased head CT utilization. Between 2012 and 2015, 12.25% (95% confidence interval [CI] 11.48-13.02%) of injury-related visits received at least one head CT. Overall head CT utilization showed an increased trend during the study period (2012: 11.7%, 2015: 13.23%, p = 0.09), but the results were not statistically significant. The diagnostic yield of head CT for a significant intracranial injury over the period of four years was 7.4% (9.68% in 2012 vs. 7.67% in 2015, p = 0.23). Head CT use along with diagnostic yield has remained stable from 2012 to 2015 among patients presenting to the ED for an injury-related visit. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Isolated Main Pancreatic Duct Dilatation: CT Differentiation Between Benign and Malignant Causes.

    PubMed

    Kim, Se Woo; Kim, Se Hyung; Lee, Dong Ho; Lee, Sang Min; Kim, Yeon Soo; Jang, Jin Young; Han, Joon Koo

    2017-11-01

    The purpose of this study is to retrospectively evaluate the differential CT features of isolated benign and malignant main pancreatic duct (MPD) dilatation and to investigate whether the diagnostic performance of radiologists can be improved with knowledge of these differential CT features. Forty-one patients who had isolated MPD dilatation without any visible mass on CT from January 2000 to October 2016 were retrospectively enrolled in the study. Two radiologists reviewed CT images in consensus for the location, shape (smooth vs abrupt), length of transition, dilated pancreatic duct (PD) diameter, presence of duct penetrating sign, parenchymal atrophy, attenuation difference, associated pancreatitis, calcification, PD or common bile duct (CBD) enhancement, and perilesional cyst. The chi-square test, Fisher exact test, and t test were used to find the differential CT features of benign and malignant MPD dilatation. Two successive review sessions for differentiation between the two disease entities were then independently performed by three other reviewers with differing expertise, with the use of a 5-point confidence scale. The first session provided no information for differentiation; however, reviewers were aware of the results of univariate analyses in the second session. The diagnostic performance of the radiologists was evaluated using a pairwise comparison of ROC curves. A total of 19 benign and 22 malignant MPD dilatations were identified. In patients with benign MPD dilatation, transition areas were frequently located in the head (57.9% [11/19] vs 13.6% [3/22], p = 0.003) and showed significantly shorter (< 6.1 mm) (78.9% [15/19] vs 9.1% [2/22], p < 0.0001) and smooth transition (89.5% [17/19] vs 9.1% [2/22], p < 0.0001). Duct penetrating sign was exclusively observed in patients with benign MPD dilatation (73.7% [14/19] vs 0% [0/22], p < 0.0001). In contrast, malignant MPD dilatation frequently was accompanied by attenuation difference (63.6% [14/22] vs 10.5% [2/19], p = 0.001) and associated PD or CBD enhancement (36.4% [8/22] vs 0% [0/19], p = 0.003). The AUC values of three reviewers significantly increased from 0.653, 0.587, and 0.884 to 0.864, 0.964, and 0.908, respectively, with knowledge of significant CT features (p = 0.013, p < 0.0001, and p = 0.701, respectively). Distal, long (≥ 6.1 mm), and abrupt transition, the absence of duct penetrating sign, and the presence of attenuation difference and PD or CBD enhancement were highly suggestive CT findings for differentiation of malignant from benign MPD dilatation. The diagnostic performance of radiologists with regard to differentiation was significantly improved with knowledge of these highly suggestive CT criteria.

  10. Diagnostic Value of 18F-FDG PET/CT Versus MRI in the Setting of Antibody-Specific Autoimmune Encephalitis.

    PubMed

    Solnes, Lilja B; Jones, Krystyna M; Rowe, Steven P; Pattanayak, Puskar; Nalluri, Abhinav; Venkatesan, Arun; Probasco, John C; Javadi, Mehrbod S

    2017-08-01

    Diagnosis of autoimmune encephalitis presents some challenges in the clinical setting because of varied clinical presentations and delay in obtaining antibody panel results. We examined the role of neuroimaging in the setting of autoimmune encephalitides, comparing the utility of 18 F-FDG PET/CT versus conventional brain imaging with MRI. Methods: A retrospective study was performed assessing the positivity rate of MRI versus 18 F-FDG PET/CT during the initial workup of 23 patients proven to have antibody-positive autoimmune encephalitis. 18 F-FDG PET/CT studies were analyzed both qualitatively and semiquantitatively. Areas of cortical lobar hypo (hyper)-metabolism in the cerebrum that were 2 SDx from the mean were recorded as abnormal. Results: On visual inspection, all patients were identified as having an abnormal pattern of 18 F-FDG uptake. In semiquantitative analysis, at least 1 region of interest with metabolic change was identified in 22 of 23 (95.6%) patients using a discriminating z score of 2. Overall, 18 F-FDG PET/CT was more often abnormal during the diagnostic period than MRI (10/23, 43% of patients). The predominant finding on brain 18 F-FDG PET/CT imaging was lobar hypometabolism, being observed in 21 of 23 (91.3%) patients. Hypometabolism was most commonly observed in the parietal lobe followed by the occipital lobe. An entire subset of antibody-positive patients, anti- N -methyl-d-aspartate receptor (5 patients), had normal MRI results and abnormal 18 F-FDG PET/CT findings whereas the other subsets demonstrated a greater heterogeneity. Conclusion: Brain 18 F-FDG PET/CT may play a significant role in the initial evaluation of patients with clinically suspected antibody-mediated autoimmune encephalitis. Given that it is more often abnormal when compared with MRI in the acute setting, this molecular imaging technique may be better positioned as an early biomarker of disease so that treatment may be initiated earlier, resulting in improved patient outcomes. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  11. Evaluation of an imaging protocol using ultrasound as the primary diagnostic modality in pediatric patients with superficial soft tissue infections of the face and neck.

    PubMed

    Sethia, Rishabh; Mahida, Justin B; Subbarayan, Rahul A; Deans, Katherine J; Minneci, Peter C; Elmaraghy, Charles A; Essig, Garth F

    2017-05-01

    To determine the clinical impact of an initiative to use ultrasound (US) as the primary diagnostic modality for children with superficial face and neck infections versus use of computed tomography (CT). Children with a diagnosis of lymphadenitis, face or neck abscess, or face and neck cellulitis were retrospectively evaluated by the otolaryngology service. Patients were separated into two groups based on implementation of a departmental initiative to use US as the primary diagnostic modality. The pre-implementation cohort consisted of patients treated prior to the initiative (2006-2009) and the current protocol cohort consisted of patients treated after the initiative was started (2010-2013). Demographics, use of US or CT, necessity of surgical intervention, and failure of medical management were compared. Three hundred seventy three children were evaluated; 114 patients were included in the pre-implementation cohort and 259 patients were included in the current protocol cohort for comparison. Patients presenting during the current protocol period were more likely to undergo US (pre-implementation vs. current protocol, p-value) (12% vs. 49%, p < 0.0001) and less likely to undergo CT (66% vs. 41%, p < 0.0001) for their initial evaluation. There were no differences in the percentage of children who underwent prompt surgical drainage, prompt discharge without surgery, or trial inpatient observation. There were also no differences in the rate of treatment failure for patients undergoing prompt surgery or prompt discharge on antibiotics. For those patients who underwent repeat evaluation following trial medical management, US was used more frequently in the current protocol period (4% vs. 20%, p = 0.002) with no difference in CT use, selected treatment strategy, or treatment failure rates. Increased use of US on initial evaluation of children with superficial face and neck infections resulted in decreased CT utilization, without negatively impacting outcome. Decreasing pediatric radiation exposure and potential long-term effects is of primary importance. Copyright © 2017. Published by Elsevier B.V.

  12. A dual tracer (68)Ga-DOTANOC PET/CT and (18)F-FDG PET/CT pilot study for detection of cardiac sarcoidosis.

    PubMed

    Gormsen, Lars C; Haraldsen, Ate; Kramer, Stine; Dias, Andre H; Kim, Won Yong; Borghammer, Per

    2016-12-01

    Cardiac sarcoidosis (CS) is a potentially fatal condition lacking a single test with acceptable diagnostic accuracy. (18)F-FDG PET/CT has emerged as a promising imaging modality, but is challenged by physiological myocardial glucose uptake. An alternative tracer, (68)Ga-DOTANOC, binds to somatostatin receptors on inflammatory cells in sarcoid granulomas. We therefore aimed to conduct a proof-of-concept study using (68)Ga-DOTANOC to diagnose CS. In addition, we compared diagnostic accuracy and inter-observer variability of (68)Ga-DOTANOC vs. (18)F-FDG PET/CT. Nineteen patients (seven female) with suspected CS were prospectively recruited and dual tracer scanned within 7 days. PET images were reviewed by four expert readers for signs of CS and compared to the reference standard (Japanese ministry of Health and Welfare CS criteria). CS was diagnosed in 3/19 patients. By consensus, 11/19 (18)F-FDG scans and 0/19 (68)Ga-DOTANOC scans were rated as inconclusive. The sensitivity of (18)F-FDG PET for diagnosing CS was 33 %, specificity was 88 %, PPV was 33 %, NPV was 88 %, and diagnostic accuracy was 79 %. For (68)Ga-DOTANOC, accuracy was 100 %. Inter-observer agreement was poor for (18)F-FDG PET (Fleiss' combined kappa 0.27, NS) and significantly better for (68)Ga-DOTANOC (Fleiss' combined kappa 0.46, p = 0.001). Despite prolonged pre-scan fasting, a large proportion of (18)F-FDG PET/CT images were rated as inconclusive, resulting in low agreement among reviewers and correspondingly poor diagnostic accuracy. By contrast, (68)Ga-DOTANOC PET/CT had excellent diagnostic accuracy with the caveat that inter-observer variability was still significant. Nevertheless, (68)Ga-DOTANOC PET/CT looks very promising as an alternative CS PET tracer. Current Controlled Trials NCT01729169 .

  13. Diagnostic Accuracy of MRI Versus CT for the Evaluation of Acute Appendicitis in Children and Young Adults.

    PubMed

    Kinner, Sonja; Pickhardt, Perry J; Riedesel, Erica L; Gill, Kara G; Robbins, Jessica B; Kitchin, Douglas R; Ziemlewicz, Timothy J; Harringa, John B; Reeder, Scott B; Repplinger, Michael D

    2017-10-01

    Appendicitis is frequently diagnosed in the emergency department, most commonly using CT. The purpose of this study was to compare the diagnostic accuracy of contrast-enhanced MRI with that of contrast-enhanced CT for the diagnosis of appendicitis in adolescents when interpreted by abdominal radiologists and pediatric radiologists. Our study included a prospectively enrolled cohort of 48 patients (12-20 years old) with nontraumatic abdominal pain who underwent CT and MRI. Fellowship-trained abdominal and pediatric radiologists reviewed all CT and MRI studies in randomized order, blinded to patient outcome. Likelihood for appendicitis was rated on a 5-point scale (1, definitely not appendicitis; 5, definitely appendicitis) for CT, the unenhanced portion of the MRI, and the entire contrast-enhanced MRI study. ROC curves were generated and AUC compared for each scan type for all six readers and then stratified by radiologist type. Image test characteristics, interrater reliability, and reading times were compared. Sensitivity and specificity were 85.9% (95% CI, 76.2-92.7%) and 93.8% (95% CI, 89.7-96.7%) for unenhanced MRI, 93.6% (95% CI, 85.6-97.9%) and 94.3% (95% CI, 90.2-97%) for contrast-enhanced MRI, and 93.6% (95% CI, 85.6-97.9%) and 94.3% (95% CI, 90.2-97%) for CT. No difference was found in the diagnostic accuracy or interpretation time when comparing abdominal radiologists to pediatric radiologists (CT, 3.0 min vs 2.8 min; contrast-enhanced MRI, 2.4 min vs 1.8 min; unenhanced MRI, 1.5 min vs 2.3 min). Substantial agreement between abdominal and pediatric radiologists was seen for all methods (κ = 0.72-0.83). The diagnostic accuracy of MRI to diagnose appendicitis was very similar to CT. No statistically significant difference in accuracy was observed between imaging modality or radiologist subspecialty.

  14. SU-F-T-92: Clinical Benefit for Breast and Chest Wall Setup in Using a Breast Board

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, S; Miyamoto, C; Serratore, D

    Purpose: To validate benefit of using a breast board (BB) by analyzing the geometry and dosimetry changes of the regions of interest (ROIs) between CT scans with and without BB. Methods: Seven patients, two chest walls (CW) and five breasts, use BB at CT simulation and no BB at diagnostic CT were included. By using deformable image registration software (Velocity AI), diagnostic CT and planning CT were rigidly co-registered according to the thoracic cage at the target. The heart and the target were then deformedly matched and the contours of the planned ROIs were transferred to the diagnostic CT. Whichmore » were brought back to the planning CT data set though the initial rigid co-registration in order to keep the deformed ROIs redefined in the diagnostic CT. Anatomic shifts and volume changes of a ROI beyond the rigid translation were recorded and dosimetry changes to ROIs were compared with recalculated DVHs. Results: Patient setup without the BB had small but systematic heart shifts superiorly by ∼5 mm. Torso rotations in two cases moved the heart in opposite directions by ∼10 mm. The breast target volume, shape, and locations were significantly changed with arm extension over the head but not in cases with the arm extended laterally. Breast setup without BB could increase the mean dose to the heart and the maximal dose to the anterior ventricle wall by 1.1 and 6.7 Gy, respectively. Conclusion: A method for evaluation of breast setup technique is introduced and applied for patients. Results of systematic heart displacement without using the BB and the potential increase of heart doses encourage us to further investigate the current trend of not using a BB for easy setup and CT scans. Using a BB would likely increase patient sag during prolonged IMRT and real-time patient position monitoring is clinically desired.« less

  15. Accuracy of iodine quantification in dual-layer spectral CT: Influence of iterative reconstruction, patient habitus and tube parameters.

    PubMed

    Sauter, Andreas P; Kopp, Felix K; Münzel, Daniela; Dangelmaier, Julia; Renz, Martin; Renger, Bernhard; Braren, Rickmer; Fingerle, Alexander A; Rummeny, Ernst J; Noël, Peter B

    2018-05-01

    Evaluation of the influence of iterative reconstruction, tube settings and patient habitus on the accuracy of iodine quantification with dual-layer spectral CT (DL-CT). A CT abdomen phantom with different extension rings and four iodine inserts (1, 2, 5 and 10 mg/ml) was scanned on a DL-CT. The phantom was scanned with tube-voltages of 120 and 140 kVp and CTDI vol of 2.5, 5, 10 and 20 mGy. Reconstructions were performed for eight levels of iterative reconstruction (i0-i7). Diagnostic dose levels are classified depending on patient-size and radiation dose. Measurements of iodine concentration showed accurate and reliable results. Taking all CTDI vol -levels into account, the mean absolute percentage difference (MAPD) showed less accuracy for low CTDI vol -levels (2.5 mGy: 34.72%) than for high CTDI vol -levels (20 mGy: 5.89%). At diagnostic dose levels, accurate quantification of iodine was possible (MAPD 3.38%). Level of iterative reconstruction did not significantly influence iodine measurements. Iodine quantification worked more accurately at a tube voltage of 140 kVp. Phantom size had a considerable effect only at low-dose-levels; at diagnostic dose levels the effect of phantom size decreased (MAPD <5% for all phantom sizes). With DL-CT, even low iodine concentrations can be accurately quantified. Accuracies are higher when diagnostic radiation doses are employed. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Diagnostic imaging and radiation exposure in inflammatory bowel disease.

    PubMed

    Zakeri, Nekisa; Pollok, Richard C G

    2016-02-21

    Diagnostic imaging plays a key role in the diagnosis and management of inflammatory bowel disease (IBD). However due to the relapsing nature of IBD, there is growing concern that IBD patients may be exposed to potentially harmful cumulative levels of ionising radiation in their lifetime, increasing malignant potential in a population already at risk. In this review we explore the proportion of IBD patients exposed to high cumulative radiation doses, the risk factors associated with higher radiation exposures, and we compare conventional diagnostic imaging with newer radiation-free imaging techniques used in the evaluation of patients with IBD. While computed tomography (CT) performs well as an imaging modality for IBD, the effective radiation dose is considerably higher than other abdominal imaging modalities. It is increasingly recognised that CT imaging remains responsible for the majority of diagnostic medical radiation to which IBD patients are exposed. Magnetic resonance imaging (MRI) and small intestine contrast enhanced ultrasonography (SICUS) have now emerged as suitable radiation-free alternatives to CT imaging, with comparable diagnostic accuracy. The routine use of MRI and SICUS for the clinical evaluation of patients with known or suspected small bowel Crohn's disease is to be encouraged wherever possible. More provision is needed for out-of-hours radiation-free imaging modalities to reduce the need for CT.

  17. Diagnostic imaging and radiation exposure in inflammatory bowel disease

    PubMed Central

    Zakeri, Nekisa; Pollok, Richard CG

    2016-01-01

    Diagnostic imaging plays a key role in the diagnosis and management of inflammatory bowel disease (IBD). However due to the relapsing nature of IBD, there is growing concern that IBD patients may be exposed to potentially harmful cumulative levels of ionising radiation in their lifetime, increasing malignant potential in a population already at risk. In this review we explore the proportion of IBD patients exposed to high cumulative radiation doses, the risk factors associated with higher radiation exposures, and we compare conventional diagnostic imaging with newer radiation-free imaging techniques used in the evaluation of patients with IBD. While computed tomography (CT) performs well as an imaging modality for IBD, the effective radiation dose is considerably higher than other abdominal imaging modalities. It is increasingly recognised that CT imaging remains responsible for the majority of diagnostic medical radiation to which IBD patients are exposed. Magnetic resonance imaging (MRI) and small intestine contrast enhanced ultrasonography (SICUS) have now emerged as suitable radiation-free alternatives to CT imaging, with comparable diagnostic accuracy. The routine use of MRI and SICUS for the clinical evaluation of patients with known or suspected small bowel Crohn’s disease is to be encouraged wherever possible. More provision is needed for out-of-hours radiation-free imaging modalities to reduce the need for CT. PMID:26900282

  18. Diagnostic value of NobelGuide to minimize the need for reconstructive surgery of jaws before implant placement: a review.

    PubMed

    Scotti, Roberto; Pellegrino, Gerardo; Marchetti, Claudio; Corinaldesi, Guiseppe; Ciocca, Leonardo

    2010-01-01

    To test if using a CAD/CAM system might reduce the necessity of bone augmentation in patients with atrophic maxillary arches before implant therapy. Twenty male and female patients consecutively scheduled for bone augmentation of the jaw before implant surgery were included in this study, with a total of 29 jaws (maxillary and mandibular) to analyze for the implant-supported fixed prosthesis group and 19 maxillary arches for the implant-supported removable prosthesis group. NobelGuide System (Nobel Biocare), Autocad System (Autodesk), and routine manual CT measurements of available bone were used in this study. The total results of the mean values of the fixed prosthesis group plus the mean values of the removable prosthesis group showed a statistically significant difference between the NobelGuide intervention score and both manual (P = .004) and Autocad (P = .001) measurements. The NobelGuide System represents a viable diagnostic device to reduce the entity or avoid bone reconstructive surgery before implant placements in the atrophic maxilla and mandible.

  19. Helical computerized tomography and NT-proBNP for screening of right ventricular overload on admission and at long term follow-up of acute pulmonary embolism.

    PubMed

    Laiho, Mia K; Harjola, Veli-Pekka; Graner, Marit; Piilonen, Anneli; Raade, Merja; Mustonen, Pirjo

    2012-05-04

    Right ventricular dysfunction (RVD) in acute pulmonary embolism (APE) can be assessed with helical computerized tomography (CT) and transthoracic echocardiography (TTE). Signs of RVD and elevated natriuretic peptides like NT-proBNP and cardiac troponin (TnT) are associated with increased risk of mortality. However, the prognostic role of both initial diagnostic strategy and the use of NT-proBNP and TnT for screening for long-term probability of RVD remains unknown. The aim of the study was to determine the role of helical CT and NT-proBNP in detection of RVD in the acute phase. In addition, the value of NT-proBNP for ruling out RVD at long-term follow-up was assessed. Sixty-three non-high risk APE patients were studied. RVD was assessed at admission in the emergency department by CT and TTE, and both NT-proBNP and TnT samples were taken. These, excepting CT, were repeated seven months later. At admission RVD was detected by CT in 37 (59 %) patients. RVD in CT correlated strongly with RVD in TTE (p < 0.0001). NT-proBNP was elevated (≥ 350 ng/l) in 32 (86 %) patients with RVD but in only seven (27 %) patients without RVD (p < 0.0001). All the patients survived until the 7-month follow-up. TTE showed persistent RVD in 6 of 63 (10 %) patients who all had RVD in CT at admission. All of them had elevated NT-proBNP levels in the follow-up compared with 5 (9 %) of patients without RVD (p < 0.0001). TTE does not confer further benefit when helical CT is used for screening for RVD in non-high risk APE. All the patients who were found to have RVD in TTE at seven months follow-up had had RVD in the acute phase CT as well. Thus, patients without RVD in diagnostic CT do not seem to require further routine follow-up to screen for RVD later. On the other hand, persistent RVD and thus need for TTE control can be ruled out by assessment of NT-proBNP at follow-up. A follow-up protocol based on these findings is suggested.

  20. Helical computerized tomography and NT-proBNP for screening of right ventricular overload on admission and at long term follow-up of acute pulmonary embolism

    PubMed Central

    2012-01-01

    Background Right ventricular dysfunction (RVD) in acute pulmonary embolism (APE) can be assessed with helical computerized tomography (CT) and transthoracic echocardiography (TTE). Signs of RVD and elevated natriuretic peptides like NT-proBNP and cardiac troponin (TnT) are associated with increased risk of mortality. However, the prognostic role of both initial diagnostic strategy and the use of NT-proBNP and TnT for screening for long-term probability of RVD remains unknown. The aim of the study was to determine the role of helical CT and NT-proBNP in detection of RVD in the acute phase. In addition, the value of NT-proBNP for ruling out RVD at long-term follow-up was assessed. Methods Sixty-three non-high risk APE patients were studied. RVD was assessed at admission in the emergency department by CT and TTE, and both NT-proBNP and TnT samples were taken. These, excepting CT, were repeated seven months later. Results At admission RVD was detected by CT in 37 (59 %) patients. RVD in CT correlated strongly with RVD in TTE (p < 0.0001). NT-proBNP was elevated (≥ 350 ng/l) in 32 (86 %) patients with RVD but in only seven (27 %) patients without RVD (p < 0.0001). All the patients survived until the 7-month follow-up. TTE showed persistent RVD in 6 of 63 (10 %) patients who all had RVD in CT at admission. All of them had elevated NT-proBNP levels in the follow-up compared with 5 (9 %) of patients without RVD (p < 0.0001). Conclusions TTE does not confer further benefit when helical CT is used for screening for RVD in non-high risk APE. All the patients who were found to have RVD in TTE at seven months follow-up had had RVD in the acute phase CT as well. Thus, patients without RVD in diagnostic CT do not seem to require further routine follow-up to screen for RVD later. On the other hand, persistent RVD and thus need for TTE control can be ruled out by assessment of NT-proBNP at follow-up. A follow-up protocol based on these findings is suggested. PMID:22559861

  1. Diagnostic value of 18F-FDG-PET/CT for the evaluation of solitary pulmonary nodules: a systematic review and meta-analysis.

    PubMed

    Ruilong, Zong; Daohai, Xie; Li, Geng; Xiaohong, Wang; Chunjie, Wang; Lei, Tian

    2017-01-01

    To carry out a meta-analysis on the performance of fluorine-18-fluorodeoxyglucose (F-FDG) PET/computed tomography (PET/CT) for the evaluation of solitary pulmonary nodules. In the meta-analysis, we performed searches of several electronic databases for relevant studies, including Google Scholar, PubMed, Cochrane Library, and several Chinese databases. The quality of all included studies was assessed by Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). Two observers independently extracted data of eligible articles. For the meta-analysis, the total sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratios were pooled. A summary receiver operating characteristic curve was constructed. The I-test was performed to assess the impact of study heterogeneity on the results of the meta-analysis. Meta-regression and subgroup analysis were carried out to investigate the potential covariates that might have considerable impacts on heterogeneity. Overall, 12 studies were included in this meta-analysis, including a total of 1297 patients and 1301 pulmonary nodules. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio with corresponding 95% confidence intervals (CIs) were 0.82 (95% CI, 0.76-0.87), 0.81 (95% CI, 0.66-0.90), 4.3 (95% CI, 2.3-7.9), and 0.22 (95% CI, 0.16-0.30), respectively. Significant heterogeneity was observed in sensitivity (I=81.1%) and specificity (I=89.6%). Subgroup analysis showed that the best results for sensitivity (0.90; 95% CI, 0.68-0.86) and accuracy (0.93; 95% CI, 0.90-0.95) were present in a prospective study. The results of our analysis suggest that PET/CT is a useful tool for detecting malignant pulmonary nodules qualitatively. Although current evidence showed moderate accuracy for PET/CT in differentiating malignant from benign solitary pulmonary nodules, further work needs to be carried out to improve its reliability.

  2. Effect of object location on the density measurement in cone-beam computed tomography versus multislice computed tomography

    PubMed Central

    Eskandarloo, Amir; Abdinian, Mehrdad; Salemi, Fatemeh; Hashemzadeh, Zahra; Safaei, Mehran

    2012-01-01

    Background: Bone density measurement in a radiographic view is a valuable method for evaluating the density of bone quality before performing some dental procedures such as, dental implant placements. It seems that Cone-Beam Computed Tomography (CBCT) can be used as a diagnostic tool for evaluating the density of the bone, prior to any treatment, as the reported radiation dose in this method is minimal. The aim of this study is to investigate the effect of object location on the density measurement in CBCT versus Multislice computed tomography (CT). Materials and Methods: In an experimental study, three samples with similar dimensions, but different compositions, different densities (Polyethylene, Polyamide, Polyvinyl Chloride), and three bone pieces of different parts of the mandibular bone were imaged in three different positions by CBCT and Multislice CT sets. The average density value was computed for each sample in each position. Then the data obtained from each CBCT was converted to a Hounsfield unit and evaluated using a single variable T analysis. A P value <0.05 was considered to be significant. Results: The density in a Multislice CT is stable in the form of a Hounsfield Number, but this density is variable in the images acquired through CBCT, and the change in the position results in significant changes in the density. In this study, a statistically significant difference (P value = 0.000) has been observed for the position of the sample and its density in CBCT in comparison to Multislice CT. Conclusions: Density values in CBCT are not real because they are affected by the position of the object in the machine. PMID:23814567

  3. Bone quality assessment for total hip arthroplasty with intraoperative trabecular torque measurements.

    PubMed

    Klotz, Matthias C M; Beckmann, Nicholas A; Bitsch, Rudi G; Seebach, Elisabeth; Reiner, Tobias; Jäger, Sebastian

    2014-11-13

    In cases of poor bone quality, intraoperative torque measurement might be an alternative to preoperative dual-energy X-ray absorptiometry (DXA) to assess bone quality in total hip arthroplasty (THA). Trabecular peak torque measurement was applied in 14 paired fresh frozen human femurs. Here, a 6.5 × 23 mm wingblade was inserted into the proximal femur without harming the lateral cortical bone. Further tests of the proximal femur also evaluated bone strength (DXA, micro-computed tomography (μCT), monoaxial compression test), and the results were compared to the trabecular torque measurement. Student's t-test was used to compare the values of the groups. Pearson product-moment was applied to correlate the values of the peak torque measurement with the bone strength measured by DXA, μCT, and monoaxial compression test. In the femoral head, the mean trabecular peak torque was 4.38 ± 1.86 Nm. These values showed a strong correlation with the values of the DXA, the μCT, and the biomechanical load test (Pearson's product-moment: DXA: 0.86, μCT-BMD: 0.80, load test: 0.85). Furthermore, the torque measurement showed a more pronounced correlation with the biomechanical load test compared to the DXA. The use of this method provides highly diagnostic information about bone quality. Since the approach was adjusted for THA, no harm of the lateral bone stock will result from this measurement during surgery. The results of this initial study employing small sample sizes indicate that this new method is as sensitive as DXA in predicting bone quality and may function as an intraoperative alternative to DXA in THA. Nevertheless, before this method will turn into clinical use, more research and clinical trials are necessary.

  4. Comparison of [68Ga]Ga-PSMA-11 PET/CT with [18F]NaF PET/CT in the evaluation of bone metastases in metastatic prostate cancer patients prior to radionuclide therapy.

    PubMed

    Uprimny, Christian; Svirydenka, Anna; Fritz, Josef; Kroiss, Alexander Stephan; Nilica, Bernhard; Decristoforo, Clemens; Haubner, Roland; von Guggenberg, Elisabeth; Buxbaum, Sabine; Horninger, Wolfgang; Virgolini, Irene Johanna

    2018-05-16

    The purpose of this study was to investigate the diagnostic performance of 68 Ga-PSMA-11 PET/CT in the evaluation of bone metastases in metastatic prostate cancer (PC) patients scheduled for radionuclide therapy in comparison to [ 18 F]sodium fluoride ( 18 F-NaF) PET/CT. Sixteen metastatic PC patients with known skeletal metastases, who underwent both 68 Ga-PSMA-11 PET/CT and 18 F-NaF PET/CT for assessment of metastatic burden prior to radionuclide therapy, were analysed retrospectively. The performance of both tracers was calculated on a lesion-based comparison. Intensity of tracer accumulation of pathologic bone lesions on 18 F-NaF PET and 68 Ga-PSMA-11 PET was measured with maximum standardized uptake values (SUV max ) and compared to background activity of normal bone. In addition, SUV max values of PET-positive bone lesions were analysed with respect to morphologic characteristics on CT. Bone metastases were either confirmed by CT or follow-up PET scan. In contrast to 468 PET-positive lesions suggestive of bone metastases on 18 F-NaF PET, only 351 of the lesions were also judged positive on 68 Ga-PSMA-11 PET (75.0%). Intensity of tracer accumulation of pathologic skeletal lesions was significantly higher on 18 F-NaF PET compared to 68 Ga-PSMA-11 PET, showing a median SUV max of 27.0 and 6.0, respectively (p < 0.001). Background activity of normal bone was lower on 68 Ga-PSMA-11 PET, with a median SUV max of 1.0 in comparison to 2.7 on 18 F-NaF PET; however, tumour to background ratio was significantly higher on 18 F-NaF PET (9.8 versus 5.9 on 68 Ga-PSMA-11 PET; p = 0.042). Based on morphologic lesion characterisation on CT, 18 F-NaF PET revealed median SUV max values of 23.6 for osteosclerotic, 35.0 for osteolytic, and 19.0 for lesions not visible on CT, whereas on 68 Ga-PSMA-11 PET median SUV max values of 5.0 in osteosclerotic, 29.5 in osteolytic, and 7.5 in lesions not seen on CT were measured. Intensity of tracer accumulation between 18 F-NaF PET and 68 Ga-PSMA-11 PET was significantly higher in osteosclerotic (p < 0.001) and lesions not visible on CT (p = 0.012). In comparison to 68 Ga-PSMA-11 PET/CT, 18 F-NaF PET/CT detects a higher number of pathologic bone lesions in advanced stage PC patients scheduled for radionuclide therapy. Our data suggest that 68 Ga-PSMA-11 PET should be combined with 18 F-NaF PET in PC patients with skeletal metastases for restaging prior to initiation or modification of therapy.

  5. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    NASA Astrophysics Data System (ADS)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    To demonstrate the feasibility of CT and B-mode Ultrasound (US) targeted HIFU, a prototype coaxial focused ultrasound transducer was registered and integrated to a CT scanner. CT and diagnostic ultrasound were used for HIFU targeting and monitoring, with the goals of both thermal ablation and non-thermal enhanced drug delivery. A 1 megahertz coaxial ultrasound transducer was custom fabricated and attached to a passive position-sensing arm and an active six degree-of-freedom robotic arm via a CT stereotactic frame. The outer therapeutic transducer with a 10 cm fixed focal zone was coaxially mounted to an inner diagnostic US transducer (2-4 megahertz, Philips Medical Systems). This coaxial US transducer was connected to a modified commercial focused ultrasound generator (Focus Surgery, Indianapolis, IN) with a maximum total acoustic power of 100 watts. This pre-clinical paradigm was tested for ability to heat tissue in phantoms with monitoring and navigation from CT and live US. The feasibility of navigation via image fusion of CT with other modalities such as PET and MRI was demonstrated. Heated water phantoms were tested for correlation between CT numbers and temperature (for ablation monitoring). The prototype transducer and integrated CT/US imaging system enabled simultaneous multimodality imaging and therapy. Pre-clinical phantom models validated the treatment paradigm and demonstrated integrated multimodality guidance and treatment monitoring. Temperature changes during phantom cooling corresponded to CT number changes. Contrast enhanced or non-enhanced CT numbers may potentially be used to monitor thermal ablation with HIFU. Integrated CT, diagnostic US, and therapeutic focused ultrasound bridges a gap between diagnosis and therapy. Preliminary results show that the multimodality system may represent a relatively inexpensive, accessible, and simple method of both targeting and monitoring HIFU effects. Small animal pre-clinical models may be translated to large animals and humans for HIFU-induced ablation and drug delivery. Integrated CT-guided focused ultrasound holds promise for tissue ablation, enhancing local drug delivery, and CT thermometry for monitoring ablation in near real-time.

  6. 18F-FDG PET/MRI fusion in characterizing pancreatic tumors: comparison to PET/CT.

    PubMed

    Tatsumi, Mitsuaki; Isohashi, Kayako; Onishi, Hiromitsu; Hori, Masatoshi; Kim, Tonsok; Higuchi, Ichiro; Inoue, Atsuo; Shimosegawa, Eku; Takeda, Yutaka; Hatazawa, Jun

    2011-08-01

    To demonstrate that positron emission tomography (PET)/magnetic resonance imaging (MRI) fusion was feasible in characterizing pancreatic tumors (PTs), comparing MRI and computed tomography (CT) as mapping images for fusion with PET as well as fused PET/MRI and PET/CT. We retrospectively reviewed 47 sets of (18)F-fluorodeoxyglucose ((18)F -FDG) PET/CT and MRI examinations to evaluate suspected or known pancreatic cancer. To assess the ability of mapping images for fusion with PET, CT (of PET/CT), T1- and T2-weighted (w) MR images (all non-contrast) were graded regarding the visibility of PT (5-point confidence scale). Fused PET/CT, PET/T1-w or T2-w MR images of the upper abdomen were evaluated to determine whether mapping images provided additional diagnostic information to PET alone (3-point scale). The overall quality of PET/CT or PET/MRI sets in diagnosis was also assessed (3-point scale). These PET/MRI-related scores were compared to PET/CT-related scores and the accuracy in characterizing PTs was compared. Forty-three PTs were visualized on CT or MRI, including 30 with abnormal FDG uptake and 13 without. The confidence score for the visibility of PT was significantly higher on T1-w MRI than CT. The scores for additional diagnostic information to PET and overall quality of each image set in diagnosis were significantly higher on the PET/T1-w MRI set than the PET/CT set. The diagnostic accuracy was higher on PET/T1-w or PET/T2-w MRI (93.0 and 90.7%, respectively) than PET/CT (88.4%), but statistical significance was not obtained. PET/MRI fusion, especially PET with T1-w MRI, was demonstrated to be superior to PET/CT in characterizing PTs, offering better mapping and fusion image quality.

  7. SU-F-T-252: An Investigation of Gamma Knife Frame Definition Error When Using a Pre-Planning Workflow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, P

    Purpose: To determine causal factors related to high frame definition error when treating GK patients using a pre-planning workflow. Methods: 160 cases were retrospectively reviewed. All patients received treatment using a pre-planning workflow whereby stereotactic coordinates are determined from a CT scan acquired after framing using a fiducial box. The planning software automatically detects the fiducials and compares their location to expected values based on the rigid design of the fiducial system. Any difference is reported as mean and maximum frame definition error. The manufacturer recommends these values be less than 1.0 mm and 1.5 mm. In this study, framemore » definition error was analyzed in comparison with a variety of factors including which neurosurgeon/oncologist/physicist was involved with the procedure, number of post used during framing (3 or 4), type of lesion, and which CT scanner was utilized for acquisition. An analysis of variance (ANOVA) approach was used to statistically evaluate the data and determine causal factors related to instances of high frame definition error. Results: Two factors were identified as significant: number of post (p=0.0003) and CT scanner (p=0.0001). Further analysis showed that one of the four scanners was significantly different than the others. This diagnostic scanner was identified as an older model with localization lasers not tightly calibrated. The average value for maximum frame definition error using this scanner was 1.48 mm (4 posts) and 1.75 mm (3 posts). For the other scanners this value was 1.13 mm (4 posts) and 1.40 mm (3 posts). Conclusion: In utilizing a pre-planning workflow the choice of CT scanner matters. Any scanner utilized for GK should undergo routine QA at a level appropriate for radiation oncology. In terms of 3 vs 4 post, it is hypothesized that three posts provide less stability during CT acquisition. This will be tested in future work.« less

  8. Feasibility Study of Using Gemstone Spectral Imaging (GSI) and Adaptive Statistical Iterative Reconstruction (ASIR) for Reducing Radiation and Iodine Contrast Dose in Abdominal CT Patients with High BMI Values.

    PubMed

    Zhu, Zheng; Zhao, Xin-ming; Zhao, Yan-feng; Wang, Xiao-yi; Zhou, Chun-wu

    2015-01-01

    To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values. 26 patients (weight > 65kg and BMI ≥ 22) underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A). Another 21 patients (weight ≤ 65kg and BMI ≥ 22) were scanned with a conventional 120 kVp tube voltage for noise index (NI) of 11 with 450mgI/kg contrast material as control group (group B). GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD), signal-noise-ratio (SNR), contrast-noise-ratio (CNR) of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis. As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684). CT dose index (CTDI) values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000), respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B. The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.

  9. Can contrast media increase organ doses in CT examinations? A clinical study.

    PubMed

    Amato, Ernesto; Salamone, Ignazio; Naso, Serena; Bottari, Antonio; Gaeta, Michele; Blandino, Alfredo

    2013-06-01

    The purpose of this article is to quantify the CT radiation dose increment in five organs resulting from the administration of iodinated contrast medium. Forty consecutive patients who underwent both un-enhanced and contrast-enhanced thoracoabdominal CT were included in our retrospective study. The dose increase between CT before and after contrast agent administration was evaluated in the portal phase for the thyroid, liver, spleen, pancreas, and kidneys by applying a previously validated method. An increase in radiation dose was noted in all organs studied. Average dose increments were 19% for liver, 71% for kidneys, 33% for spleen and pancreas, and 41% for thyroid. Kidneys exhibited the maximum dose increment, whereas the pancreas showed the widest variance because of the differences in fibro-fatty involution. Finally, thyroids with high attenuation values on unenhanced CT showed a lower Hounsfield unit increase and, thus, a smaller increment in the dose. Our study showed an increase in radiation dose in several parenchymatous tissues on contrast-enhanced CT. Our method allowed us to evaluate the dose increase from the change in attenuation measured in Hounsfield units. Because diagnostic protocols require multiple acquisitions after the contrast agent administration, such a dose increase should be considered when optimizing these protocols.

  10. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    PubMed

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  11. Osteoblastic lesion screening with an advanced post-processing package enabling in-plane rib reading in CT-images.

    PubMed

    Seuss, Hannes; Dankerl, Peter; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2016-05-20

    To evaluate screening and diagnostic accuracy for the detection of osteoblastic rib lesions using an advanced post-processing package enabling in-plane rib reading in CT-images. We retrospectively assessed the CT-data of 60 consecutive prostate cancer patients by applying dedicated software enabling in-plane rib reading. Reading the conventional multiplanar reconstructions was considered to be the reference standard. To simulate clinical practice, the reader was given 10 s to screen for sclerotic rib lesions in each patient applying both approaches. Afterwards, every rib was evaluated individually with both approaches without a time limit. Sensitivities, specificities, positive/negative predictive values and the time needed for detection were calculated depending on the lesion's size (largest diameter < 5 mm, 5-10 mm, > 10 mm). In 53 of 60 patients, all ribs were properly displayed in plane, in five patients ribs were partially displayed correctly, and in two patients none of the ribs were displayed correctly. During the 10-s screening approach all patients with sclerotic rib lesions were correctly identified reading the in-plane images (including the patients without a correct rib segmentation), whereas 14 of 23 patients were correctly identified reading conventional multiplanar images. Overall screening sensitivity, specificity, and positive/negative predictive values were 100/27.0/46.0/100 %, respectively, for in-plane reading and 60.9/100/100/80.4 %, respectively, for multiplanar reading. Overall diagnostic (no time limit) sensitivity, specificity, and positive/negative predictive values of in-plane reading were 97.8/92.8/74.6/99.5 %, respectively. False positive results predominantly occurred for lesions <5 mm in size. In-plane reading of the ribs allows reliable detection of osteoblastic lesions for screening purposes. The limited specificity results from false positives predominantly occurring for small lesions.

  12. Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions.

    PubMed

    Eiber, Matthias; Martinez-Möller, Axel; Souvatzoglou, Michael; Holzapfel, Konstantin; Pickhard, Anja; Löffelbein, Dennys; Santi, Ivan; Rummeny, Ernst J; Ziegler, Sibylle; Schwaiger, Markus; Nekolla, Stephan G; Beer, Ambros J

    2011-09-01

    In this study, the potential contribution of Dixon-based MR imaging with a rapid low-resolution breath-hold sequence, which is a technique used for MR-based attenuation correction (AC) for MR/positron emission tomography (PET), was evaluated for anatomical correlation of PET-positive lesions on a 3T clinical scanner compared to low-dose CT. This technique is also used in a recently installed fully integrated whole-body MR/PET system. Thirty-five patients routinely scheduled for oncological staging underwent (18)F-fluorodeoxyglucose (FDG) PET/CT and a 2-point Dixon 3-D volumetric interpolated breath-hold examination (VIBE) T1-weighted MR sequence on the same day. Two PET data sets reconstructed using attenuation maps from low-dose CT (PET(AC_CT)) or simulated MR-based segmentation (PET(AC_MR)) were evaluated for focal PET-positive lesions. The certainty for the correlation with anatomical structures was judged in the low-dose CT and Dixon-based MRI on a 4-point scale (0-3). In addition, the standardized uptake values (SUVs) for PET(AC_CT) and PET(AC_MR) were compared. Statistically, no significant difference could be found concerning anatomical localization for all 81 PET-positive lesions in low-dose CT compared to Dixon-based MR (mean 2.51 ± 0.85 and 2.37 ± 0.87, respectively; p = 0.1909). CT tended to be superior for small lymph nodes, bone metastases and pulmonary nodules, while Dixon-based MR proved advantageous for soft tissue pathologies like head/neck tumours and liver metastases. For the PET(AC_CT)- and PET(AC_MR)-based SUVs (mean 6.36 ± 4.47 and 6.31 ± 4.52, respectively) a nearly complete concordance with a highly significant correlation was found (r = 0.9975, p < 0.0001). Dixon-based MR imaging for MR AC allows for anatomical allocation of PET-positive lesions similar to low-dose CT in conventional PET/CT. Thus, this approach appears to be useful for future MR/PET for body regions not fully covered by diagnostic MRI due to potential time constraints.

  13. Radiochromic film calibration for the RQT9 quality beam

    NASA Astrophysics Data System (ADS)

    Costa, K. C.; Gomez, A. M. L.; Alonso, T. C.; Mourao, A. P.

    2017-11-01

    When ionizing radiation interacts with matter it generates energy deposition. Radiation dosimetry is important for medical applications of ionizing radiation due to the increasing demand for diagnostic radiology and radiotherapy. Different dosimetry methods are used and each one has its advantages and disadvantages. The film is a dose measurement method that records the energy deposition by the darkening of its emulsion. Radiochromic films have a little visible light sensitivity and respond better to ionizing radiation exposure. The aim of this study is to obtain the resulting calibration curve by the irradiation of radiochromic film strips, making it possible to relate the darkening of the film with the absorbed dose, in order to measure doses in experiments with X-ray beam of 120 kV, in computed tomography (CT). Film strips of GAFCHROMIC XR-QA2 were exposed according to RQT9 reference radiation, which defines an X-ray beam generated from a voltage of 120 kV. Strips were irradiated in "Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear" (LCD / CDTN) at a dose range of 5-30 mGy, corresponding to the range values commonly used in CT scans. Digital images of the irradiated films were analyzed by using the ImageJ software. The darkening responses on film strips according to the doses were observed and they allowed obtaining the corresponding numeric values to the darkening for each specific dose value. From the numerical values of darkening, a calibration curve was obtained, which correlates the darkening of the film strip with dose values in mGy. The calibration curve equation is a simplified method for obtaining absorbed dose values using digital images of radiochromic films irradiated. With the calibration curve, radiochromic films may be applied on dosimetry in experiments on CT scans using X-ray beam of 120 kV, in order to improve CT acquisition image processes.

  14. SU-F-J-39: Dose Reduction Strategy Using Attenuation-Based Tube Current Modulation Method in CBCT for IGRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Son, K; Lee, H; Kim, C

    2016-06-15

    Purpose: To reduce radiation dose to the patients, tube current modulation (TCM) method has been actively used in diagnostic CT systems. However, TCM method has not yet been applied to a kV-CBCT system on a LINAC machine. The purpose of this study is to investigate whether the use of TCM method is desirable in kV-CBCT system for IGRT. We have developed an attenuation-based tube current modulation (a-TCM) method using the prior knowledge of treatment CT image of a patient. Methods: Patients go through a diagnostic CT scan for RT planning; therefore, using this prior information of CT images, one canmore » estimate the total attenuation of an x-ray through the patient body in a CBCT setting for radiation therapy. We performed a numerical study incorporating major factors into account such as polychromatic x-ray, scatter, noise, and bow-tie filter to demonstrate that a-TCM method can produce equivalent quality of images at reduced imaging radiation doses. Using the CT projector program, 680 projection images of the pediatric XCAT phantom were obtained both in conventional scanning condition, i.e., without modulating the tube current, and in the proposed a-TCM scanning condition. FDK reconstruction algorithm was used for image reconstruction, and the organ dose due to imaging radiation has been calculated in both cases and compared using GATE/Geant4 simulation toolkit. Results: Reconstructed CT images in the a-TCM method showed similar SSIM values and noise properties to the reference images acquired by the conventional CBCT. In addition, reduction of organ doses ranged from 12% to 27%. Conclusion: We have successfully demonstrated the feasibility and dosimetric merit of the a-TCM method for kV-CBCT, and envision that it can be a useful option of CBCT scanning that provides patient dose reduction without degrading image quality.« less

  15. Identification of benign and malignant thyroid nodules by in vivo iodine concentration measurement using single-source dual energy CT

    PubMed Central

    Gao, Shun-Yu; Zhang, Xiao-Yan; Wei, Wei; Li, Xiao-Ting; Li, Yan-Ling; Xu, Min; Sun, Ying-Shi; Zhang, Xiao-Peng

    2016-01-01

    Abstract This study proposed to determine whether in vivo iodine concentration measurement by single-source dual energy (SSDE) CT can improve differentiation between benign and malignant thyroid nodules. In total, 53 patients presenting with thyroid nodules underwent SSDE CT scanning. Iodine concentrations were measured for each nodule and normal thyroid tissue using the GSI-viewer image analysis software. A total of 26 thyroid nodules were malignant in 26 patients and confirmed by surgery; 33 nodules from 27 patients were benign, with 10 confirmed by surgery and others after follow-up. Iodine concentrations with plain CT were significantly lower in malignant than benign nodules (0.47 ± 0.20 vs 1.17 ± 0.38 mg/mL, P = 0.00). Receiver operating characteristic (ROC) curve showed an area under the curve (AUC) of 0.93; with a cutoff of 0.67, iodine concentration showed 92.3% sensitivity and 88.5% specificity in diagnosing malignancy. Iodine concentration obtained by enhanced and plain CT were significantly higher in malignant than benign nodules (9.05 ± 3.35 vs 3.46 ± 2.24 mg/mL, P = 0.00). ROC curve analysis showed an AUC of 0.93; with a cutoff value of 3.37, iodine concentration displayed 78% sensitivity, 95% specificity in diagnosing malignancy. Combining unenhanced with enhanced iodine concentrations, the diagnostic equation was: Y = –8.641 × unenhanced iodine concentration + 0.663 × iodine concentration. ROC curve showed an AUC of 0.98 (95% CI, 0.94, 1.00). With Y ≥ –2 considered malignancy, diagnostic sensitivity and specificity were 96%, 96.3%, respectively. This study concluded that SSDE CT can detect the differences in iodine uptake and blood supply between benign and malignant thyroid lesions. PMID:27684811

  16. Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT.

    PubMed

    Park, Clara; Gruber-Rouh, Tatjana; Leithner, Doris; Zierden, Amelie; Albrecht, Mortiz H; Wichmann, Julian L; Bodelle, Boris; Elsabaie, Mohamed; Scholtz, Jan-Erik; Kaup, Moritz; Vogl, Thomas J; Beeres, Martin

    2016-10-10

    Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging. This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 patients with contrast-enhanced chest-abdomen-pelvis CT for gynaecologic cancer staging. All patients were examined with activated ATPS for adaption of tube voltage to body habitus. 50 patients were scanned on a third-generation dual-source CT (DSCT), and another 50 patients on a second-generation DSCT. Predefined image quality setting remained stable between both groups at 120 kV and a current of 210 Reference mAs. Subjective image quality assessment was performed by two blinded readers independently. Attenuation and image noise were measured in several anatomic structures. Signal-to-noise ratio (SNR) was calculated. For the evaluation of radiation exposure, CT dose index (CTDI vol ) values were compared. Diagnostic image quality was obtained in all patients. The median CTDI vol (6.1 mGy, range 3.9-22 mGy) was 40 % lower when using the algorithm compared with the previous ATCM protocol (median 10.2 mGy · cm, range 5.8-22.8 mGy). A reduction in potential to 90 kV occurred in 19 cases, a reduction to 100 kV in 23 patients and a reduction to 110 kV in 3 patients of our experimental cohort. These patients received significantly lower radiation exposure compared to the former used protocol. Latest generation automated ATPS on third-generation DSCT provides good diagnostic image quality in chest-abdomen-pelvis CT while average radiation dose is reduced by 40 % compared to former ATPS protocol on second-generation DSCT.

  17. MO-FG-CAMPUS-IeP1-03: Establishment of Provincial Diagnostic Reference Levels in Pediatric Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tonkopi, E; Queen Elizabeth II Health Sciences Ctr; O’Brien, K

    Purpose: To establish provincial diagnostic reference levels (DRLs) in pediatric general radiography and computed tomography (CT) as a tool for the optimization of exposure parameters. Methods: Patient dose survey was conducted in the only pediatric hospital in the province of Nova Scotia. The DRLs were established as the 75th percentile of patient dose distributions in different age groups. For routine radiography projections the DRLs were determined in terms of entrance surface dose (ESD) calculated from the radiation output measurements and the tube current-exposure time product (mAs) recorded for each examination. Patient thickness was measured by the technologist during the examination.more » The CR and DR systems, employing respectively a fixed technique and phototiming, were evaluated separately; a two-tailed Student’s t-test was used to determine the significance of differences between the means of dose distributions. The CT studies included routine head, chest, abdomen/pelvis, and chest/abdomen/pelvis. The volume CT dose index (CTDIvol) and dose-length product (DLP) values were extracted retrospectively from PACS. The correction factors based on the effective diameter of the patient were applied to the CT dosimetry metrics based on the standard phantoms. Results: The provincial DRLs were established in the following age groups: newborn, 1, 5, 10, and 15 year olds. In general radiography the DR systems demonstrated slightly lower dose than the CR for all views, however the differences were not statistically significant (p > 0.05) for all examinations. In CT the provincial DRLs were lower than the published data, except for head DLPs in all age categories. This might be due to the small patient sample size in the survey. Future work will include additional CT data collection over an extended period of time. Conclusion: Provincial DRLs were established in the dedicated children’s hospital to provide guidance for the other facilities in examinations of pediatric patients.« less

  18. SU-E-J-251: Incorporation of Pre-Therapy 18F-FDG Uptake with CT Texture Features in a Predictive Model for Radiation Pneumonitis Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anthony, G; Cunliffe, A; Armato, S

    2015-06-15

    Purpose: To determine whether the addition of standardized uptake value (SUV) statistical variables to CT lung texture features can improve a predictive model of radiation pneumonitis (RP) development in patients undergoing radiation therapy. Methods: Anonymized data from 96 esophageal cancer patients (18 RP-positive cases of Grade ≥ 2) were retrospectively collected including pre-therapy PET/CT scans, pre-/posttherapy diagnostic CT scans and RP status. Twenty texture features (firstorder, fractal, Laws’ filter and gray-level co-occurrence matrix) were calculated from diagnostic CT scans and compared in anatomically matched regions of the lung. The mean, maximum, standard deviation, and 50th–95th percentiles of the SUV valuesmore » for all lung voxels in the corresponding PET scans were acquired. For each texture feature, a logistic regression-based classifier consisting of (1) the average change in that texture feature value between the pre- and post-therapy CT scans and (2) the pre-therapy SUV standard deviation (SUV{sub SD}) was created. The RP-classification performance of each logistic regression model was compared to the performance of its texture feature alone by computing areas under the receiver operating characteristic curves (AUCs). T-tests were performed to determine whether the mean AUC across texture features changed significantly when SUV{sub SD} was added to the classifier. Results: The AUC for single-texturefeature classifiers ranged from 0.58–0.81 in high-dose (≥ 30 Gy) regions of the lungs and from 0.53–0.71 in low-dose (< 10 Gy) regions. Adding SUVSD in a logistic regression model using a 50/50 data partition for training and testing significantly increased the mean AUC by 0.08, 0.06 and 0.04 in the low-, medium- and high-dose regions, respectively. Conclusion: Addition of SUVSD from a pre-therapy PET scan to a single CT-based texture feature improves RP-classification performance on average. These findings demonstrate the potential for more accurate prediction of RP using information from multiple imaging modalities. Supported, in part, by the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health under grant number T32 EB002103; SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology. HA receives royalties through the University of Chicago for computer-aided diagnosis technology.« less

  19. Diagnostic value of contrast-enhanced CT combined with 18-FDG PET in patients selected for cytoreductive surgery and hyperthermic intraperitoneal chemotherapy (HIPEC).

    PubMed

    Sommariva, Antonio; Evangelista, Laura; Pintacuda, Giovanna; Cervino, Anna Rita; Ramondo, Gaetano; Rossi, Carlo Riccardo

    2018-05-01

    Aim of the study is to assess the reliability and correlation with surgical peritoneal cancer index (PCI) of combined PET/CT and ceCT scans (PET/ceCT) performed in a session in patients with peritoneal carcinomatosis candidates for cytoreductive surgery (CS) and hyperthermic intraperitoneal chemotherapy (HIPEC). We retrospectively analyzed data collected from 27 patients with different types of peritoneal carcinomatosis candidates to CS + HIPEC who underwent FDG PET/ceCT in a single session. Two nuclear medicine physicians and two radiologists independently and blindly evaluated PET/CT and ceCT imaging, respectively. In the case of discordance, the consensus was reached by a discussion between the specialists. Moreover, the combined images were evaluated by all the specialists in consensus. The PCIs obtained from surgical look, PET/CT, ceCT, and PET/ceCT were compared with each other. The coefficients of correlation (r) were calculated. The study was conducted after approval of local ethics committee. Surgical PCI was available in 21 patients. The coefficient of correlation between PCI of PET/CT and surgery was 0.528, while it resulted higher between PET/ceCT and surgery (r = 0.878), very similar to ceCT and surgery (r = 0.876). The r coefficient between surgical PCI and PET/CT was higher in patients with a non-mucinous cancer (n = 12) than the counterpart (0.601 vs. 0.303) and the addition of ceCT significantly increases the correlation (r = 0.863), which is anyway similar to ceCT alone (r = 0.856). PET/ceCT as single examination is more accurate than PET/CT but not than ceCT alone for the definition of PCI in a selected group of patients candidates to CS + HIPEC.

  20. The Role of Post-Resuscitation Electrocardiogram in Patients With ST-Segment Changes in the Immediate Post-Cardiac Arrest Period.

    PubMed

    Kim, Youn-Jung; Min, Sun-Yang; Lee, Dong Hun; Lee, Byung Kook; Jeung, Kyung Woon; Lee, Hui Jai; Shin, Jonghwan; Ko, Byuk Sung; Ahn, Shin; Nam, Gi-Byoung; Lim, Kyoung Soo; Kim, Won Young

    2017-03-13

    The authors aimed to evaluate the role of post-resuscitation electrocardiogram (ECG) in patients showing significant ST-segment changes on the initial ECG and to provide useful diagnostic indicators for physicians to determine in which out-of-hospital cardiac arrest (OHCA) patients brain computed tomography (CT) should be performed before emergency coronary angiography. The usefulness of immediate brain CT and ECG for all resuscitated patients with nontraumatic OHCA remains controversial. Between January 2010 and December 2014, 1,088 consecutive adult nontraumatic patients with return of spontaneous circulation who visited the emergency department of 3 tertiary care hospitals were enrolled. After excluding 245 patients with obvious extracardiac causes, 200 patients were finally included. The patients were categorized into 2 groups: those with ST-segment changes with spontaneous subarachnoid hemorrhage (SAH) (n = 50) and those with OHCA of suspected cardiac origin group (n = 150). The combination of 4 ECG characteristics including narrow QRS (<120 ms), atrial fibrillation, prolonged QTc interval (≥460 ms), and ≥4 ST-segment depressions had a 66.0% sensitivity, 80.0% specificity, 52.4% positive predictive value, and 87.6% negative predictive value for predicting SAH. The area under the receiver-operating characteristic curves in the post-resuscitation ECG findings was 0.816 for SAH. SAH was observed in a substantial number of OHCA survivors (25.0%) with significant ST-segment changes on post-resuscitation ECG. Resuscitated patients with narrow QRS complex and any 2 ECG findings of atrial fibrillation, QTc interval prolongation, or ≥4 ST-segment depressions may help identify patients who need brain CT as the next diagnostic work-up. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Trabecular bone analysis in CT and X-ray images of the proximal femur for the assessment of local bone quality.

    PubMed

    Fritscher, Karl; Grunerbl, Agnes; Hanni, Markus; Suhm, Norbert; Hengg, Clemens; Schubert, Rainer

    2009-10-01

    Currently, conventional X-ray and CT images as well as invasive methods performed during the surgical intervention are used to judge the local quality of a fractured proximal femur. However, these approaches are either dependent on the surgeon's experience or cannot assist diagnostic and planning tasks preoperatively. Therefore, in this work a method for the individual analysis of local bone quality in the proximal femur based on model-based analysis of CT- and X-ray images of femur specimen will be proposed. A combined representation of shape and spatial intensity distribution of an object and different statistical approaches for dimensionality reduction are used to create a statistical appearance model in order to assess the local bone quality in CT and X-ray images. The developed algorithms are tested and evaluated on 28 femur specimen. It will be shown that the tools and algorithms presented herein are highly adequate to automatically and objectively predict bone mineral density values as well as a biomechanical parameter of the bone that can be measured intraoperatively.

  2. Trisomy 8, a Cytogenetic Abnormality in Myelodysplastic Syndromes, Is Constitutional or Not?

    PubMed Central

    Saumell, Sílvia; Solé, Francesc; Arenillas, Leonor; Montoro, Julia; Valcárcel, David; Pedro, Carme; Sanzo, Carmen; Luño, Elisa; Giménez, Teresa; Arnan, Montserrat; Pomares, Helena; De Paz, Raquel; Arrizabalaga, Beatriz; Jerez, Andrés; Martínez, Ana B.; Sánchez-Castro, Judith; Rodríguez-Gambarte, Juan D.; Raya, José M.; Ríos, Eduardo; Rodríguez-Rivera, María; Espinet, Blanca; Florensa, Lourdes

    2015-01-01

    Isolated trisomy 8 is not considered presumptive evidence of myelodysplastic syndrome (MDS) in cases without minimal morphological criteria. One reason given is that trisomy 8 (+8) can be found as a constitutional mosaicism (cT8M). We tried to clarify the incidence of cT8M in myeloid neoplasms, specifically in MDS, and the diagnostic value of isolated +8 in MDS. Twenty-two MDS and 10 other myeloid neoplasms carrying +8 were studied. Trisomy 8 was determined in peripheral blood by conventional cytogenetics (CC) and on granulocytes, CD3+ lymphocytes and oral mucosa cells by fluorescence in situ hybridization (FISH). In peripheral blood CC, +8 was seen in 4/32 patients. By FISH, only one patient with chronic myelomonocytic leukemia showed +8 in all cell samples and was interpreted as a cT8M. In our series +8 was acquired in all MDS. Probably, once discarded cT8M by FISH from CD3+ lymphocytes and non-hematological cells, +8 should be considered with enough evidence to MDS. PMID:26066831

  3. Trisomy 8, a Cytogenetic Abnormality in Myelodysplastic Syndromes, Is Constitutional or Not?

    PubMed

    Saumell, Sílvia; Solé, Francesc; Arenillas, Leonor; Montoro, Julia; Valcárcel, David; Pedro, Carme; Sanzo, Carmen; Luño, Elisa; Giménez, Teresa; Arnan, Montserrat; Pomares, Helena; De Paz, Raquel; Arrizabalaga, Beatriz; Jerez, Andrés; Martínez, Ana B; Sánchez-Castro, Judith; Rodríguez-Gambarte, Juan D; Raya, José M; Ríos, Eduardo; Rodríguez-Rivera, María; Espinet, Blanca; Florensa, Lourdes

    2015-01-01

    Isolated trisomy 8 is not considered presumptive evidence of myelodysplastic syndrome (MDS) in cases without minimal morphological criteria. One reason given is that trisomy 8 (+8) can be found as a constitutional mosaicism (cT8M). We tried to clarify the incidence of cT8M in myeloid neoplasms, specifically in MDS, and the diagnostic value of isolated +8 in MDS. Twenty-two MDS and 10 other myeloid neoplasms carrying +8 were studied. Trisomy 8 was determined in peripheral blood by conventional cytogenetics (CC) and on granulocytes, CD3+ lymphocytes and oral mucosa cells by fluorescence in situ hybridization (FISH). In peripheral blood CC, +8 was seen in 4/32 patients. By FISH, only one patient with chronic myelomonocytic leukemia showed +8 in all cell samples and was interpreted as a cT8M. In our series +8 was acquired in all MDS. Probably, once discarded cT8M by FISH from CD3+ lymphocytes and non-hematological cells, +8 should be considered with enough evidence to MDS.

  4. Cardiotoxicity and cancer therapy: treatment-related cardiac morbidity in patients presenting with symptoms suggestive of heart or lung disease.

    PubMed

    Wieshammer, Siegfried; Dreyhaupt, Jens; Müller, Dirk; Momm, Felix; Jakob, Andreas; Freund, Ulrich

    2013-01-01

    Cardiac injury is one of the complications of cancer treatment. This study aimed to investigate the relationships between the types of radiotherapy of the chest (RT), chemotherapy (CT), cancer surgery (CS) and endocrine therapy (ET), and the presence of heart disease, and their associations with the serum level of N-terminal pro-B-type natriuretic peptide (NT-proBNP). A consecutive series of 374 patients with cancer who were referred because of symptoms suggestive of heart or lung disease prospectively underwent a diagnostic workup. The prevalence of heart disease was 36.9%. RT administered before 1995 (n = 19) was associated with both increased odds of heart disease [adjusted odds ratio 10.3, 95% confidence interval 3.1-34.0] and higher ln-transformed NT-proBNP values (p < 0.01) compared to the control group (no RT or RT for right-sided breast cancer from 1995 onwards; n = 311). Anthracycline-treated patients (n = 54) had higher adjusted values for ln(NT-proBNP) compared to the control group (no CT; n = 243; p < 0.01) but no increased odds of heart disease. While pre-1995 RT and anthracycline-containing CT were associated with cardiac effects, there was no evidence that RT using modern cardioprotective techniques, CT in the absence of anthracyclines, CS or ET had detrimental effects on the heart. Copyright © 2013 S. Karger AG, Basel.

  5. Diagnostic accuracy of contrast-enhanced computed tomography and contrast-enhanced magnetic resonance imaging of small renal masses in real practice: sensitivity and specificity according to subjective radiologic interpretation.

    PubMed

    Kim, Jae Heon; Sun, Hwa Yeon; Hwang, Jiyoung; Hong, Seong Sook; Cho, Yong Jin; Doo, Seung Whan; Yang, Won Jae; Song, Yun Seob

    2016-10-12

    The aim of this study was to investigate the diagnostic accuracy of contrast-enhanced computed tomography (CT) and contrast-enhanced magnetic resonance imaging (MRI) of small renal masses in real practice. Contrast-enhanced CT and MRI were performed between February 2008 and February 2013 on 68 patients who had suspected small (≤4 cm) renal cell carcinoma (RCC) based on ultrasonographic measurements. CT and MRI radiographs were reviewed, and the findings of small renal masses were re-categorized into five dichotomized scales by the same two radiologists who had interpreted the original images. Receiver operating characteristics curve analysis was performed, and sensitivity and specificity were determined. Among the 68 patients, 60 (88.2 %) had RCC and eight had benign disease. The diagnostic accuracy rates of contrast-enhanced CT and MRI were 79.41 and 88.23 %, respectively. Diagnostic accuracy was greater when using contrast-enhanced MRI because too many masses (67.6 %) were characterized as "4 (probably solid cancer) or 5 (definitely solid cancer)." The sensitivity of contrast-enhanced CT and MRI for predicting RCC were 79.7 and 88.1 %, respectively. The specificities of contrast-enhanced CT and MRI for predicting RCC were 44.4 and 33.3 %, respectively. Fourteen diagnoses (20.5 %) were missed or inconsistent compared with the final pathological diagnoses. One appropriate nephroureterectomy and five unnecessary percutaneous biopsies were performed for RCC. Seven unnecessary partial nephrectomies were performed for benign disease. Although contrast-enhanced CT and MRI showed high sensitivity for detecting small renal masses, specificity remained low.

  6. Computed tomography in the evaluation of penetrating neck trauma: a preliminary study.

    PubMed

    Gracias, V H; Reilly, P M; Philpott, J; Klein, W P; Lee, S Y; Singer, M; Schwab, C W

    2001-11-01

    Penetrating neck trauma has traditionally been evaluated by surgical exploration and/or invasive diagnostic studies. We hypothesized that computed tomography (CT), used as an early diagnostic tool to accurately determine trajectory, would direct or eliminate further studies or procedures in stable patients with penetrating neck trauma. Retrospective case series. Academic, urban, level I trauma center. Hemodynamically stable patients without hard signs of vascular injury or aerodigestive violation who had sustained penetrating trauma to the neck. Patients underwent a spiral CT as an initial diagnostic study after initial evaluation in the trauma bay. Further invasive studies were directed by CT findings. Number of invasive studies performed. Twenty-three patients were identified during the 30-month period. Nineteen patients sustained gunshot wounds; 3, shotgun wounds; and 1, a stab wound. One patient died of a cranial gunshot wound. Three isolated zone I, 1 isolated zone II, 9 isolated zone III, and 10 multiple neck zone trajectories were evaluated. Thirteen patients were identified by CT to have trajectories remote from vital structures and required no further evaluation. Ten patients underwent angiography. Only 2 underwent bronchoscopy and esophagoscopy. Four patients were discharged from the emergency department; 7 other patients were discharged within 24 hours. No adverse patient events occurred before, during, or after CT scan. Computed tomography in stable selected patients with penetrating neck trauma appears safe. Invasive studies can often be eliminated from the diagnostic algorithm when CT demonstrates trajectories remote from vital structures. As a result, efficient evaluation and early discharge from the trauma bay or emergency department can be realized. Further prospective study of CT scan after penetrating neck trauma is needed.

  7. Ovarian torsion: diagnostic features on CT and MRI with pathologic correlation.

    PubMed

    Duigenan, Shauna; Oliva, Esther; Lee, Susanna I

    2012-02-01

    The CT and MRI features of ovarian torsion are illustrated with gross pathologic correlation. Ovarian enlargement with or without an underlying mass is the finding most frequently associated with torsion, but it is nonspecific. A twisted pedicle, although not often detected on imaging, is pathognomonic when seen. Subacute ovarian hemorrhage and abnormal enhancement is usually seen, and both features show characteristic patterns on CT and MRI. Ipsilateral uterine deviation can also be seen. Diagnostic pitfalls that may mimic ovarian torsion and observations for discriminating them are discussed.

  8. CT for all or selective approach? Who really needs a cervical spine CT after blunt trauma.

    PubMed

    Duane, Therèse M; Young, Andrew; Mayglothling, Julie; Wilson, Sean P; Weber, William F; Wolfe, Luke G; Ivatury, Rao R

    2013-04-01

    Computed tomography (CT) is the standard to screen blunt trauma patients for cervical spine (c-spine) fractures, yet there remains a reluctance to scan all trauma team activations because of radiation exposure and cost. The purpose of this study was to identify predictors of positive CT in an effort to decrease future CT use without compromising patient care. We performed a prospective study in which we documented 18 combined NEXUS and Canadian c-spine criteria on 5,182 patients before CT comparing those with and without fractures to identify predictors of injury. Clinical examination was considered positive if any of the 18 criteria were positive. There were 324 patients with a fracture, for an incidence rate of 6.25%. Fracture patients were older (43.89 ± 18.83 years vs. 38.42 ± 17.45 years, p <; 0.0001), with a lower GCS (Glasgow Coma Scale) score (13.49 ± 3.49 vs. 14.32 ± 2.34, p < 0.0001), than nonfracture patients. Clinical examination had a 100% (324 of 324) sensitivity, 0.62% (30 of 4,858) specificity, 6.29% (324 of 5,152) positive predictive value, and 100% (30 of 30) negative predictive value. A total of 77.8% (14 of 18) criteria were significantly associated with fracture by univariate analysis, seven of which were independent predictors of fracture by logistic regression (midline tenderness, GCS score < 15, age ≥65 years, paresthesias, rollover motor vehicle collision, ejected, never in sitting position in emergency department). Evaluation of these seven factors demonstrated a sensitivity of 99.07% (321 of 324), positive predictive value of 6.95% (321 of 4,617), specificity of 11.57% (562 of 4,858), and negative predictive value of 99.47% (562 of 565). Although sensitive, the standard clinical criteria used to determine patients who need radiographs lack specificity. Based on these results, more narrow criteria should be validated in an effort to limit the number of c-spine CTs while not compromising patient care. Prognostic study, level II; diagnostic study, level II.

  9. Variation in Diagnostic Performance among Radiologists at Screening CT Colonography

    PubMed Central

    Pooler, B. Dustin; Kim, David H.; Hassan, Cesare; Rinaldi, Antonio; Burnside, Elizabeth S.

    2013-01-01

    Purpose: To assess the variation in diagnostic performance among radiologists at screening computed tomographic (CT) colonography. Materials and Methods: In this HIPAA-compliant, institutional review board–approved study, 6866 asymptomatic adults underwent first-time CT colonographic screening at a single center between January 2005 and November 2011. Results of examinations were interpreted by one of eight board-certified abdominal radiologists (mean number of CT colonographic studies per reader, 858; range, 131–2202). Findings at CT colonography and subsequent colonoscopy were recorded, and key measures of diagnostic performance, including adenoma and advanced neoplasia detection rate, were compared among the radiologists. Results: The overall prevalence of histopathologically confirmed advanced neoplasia was 3.6% and did not differ significantly among radiologists (range, 2.4%–4.4%; P = .067; P = .395 when one outlier was excluded). Overall, 19.5% of polyps detected at CT colonography proved to be advanced neoplasia and did not differ significantly among radiologists (range, 14.4%–23.2%; P = .223). The overall per-polyp endoscopic confirmation rate was 93.5%, ranging from 80.0% to 97.6% among radiologists (P = .585). The overall percentage of nondiagnostic CT colonographic examinations was 0.7% and was consistent among radiologists (range, 0.3%–1.1%; P = .509). Conclusion: Consistent performance for adenoma and advanced neoplasia detection, as well as other clinically relevant end points, were observed among radiologists at CT colonographic screening. © RSNA, 2013 PMID:23449954

  10. Echocardiography as an indication of continuous-time cardiac quiescence

    NASA Astrophysics Data System (ADS)

    Wick, C. A.; Auffermann, W. F.; Shah, A. J.; Inan, O. T.; Bhatti, P. T.; Tridandapani, S.

    2016-07-01

    Cardiac computed tomography (CT) angiography using prospective gating requires that data be acquired during intervals of minimal cardiac motion to obtain diagnostic images of the coronary vessels free of motion artifacts. This work is intended to assess B-mode echocardiography as a continuous-time indication of these quiescent periods to determine if echocardiography can be used as a cost-efficient, non-ionizing modality to develop new prospective gating techniques for cardiac CT. These new prospective gating approaches will not be based on echocardiography itself but on CT-compatible modalities derived from the mechanics of the heart (e.g. seismocardiography and impedance cardiography), unlike the current standard electrocardiogram. To this end, echocardiography and retrospectively-gated CT data were obtained from ten patients with varied cardiac conditions. CT reconstructions were made throughout the cardiac cycle. Motion of the interventricular septum (IVS) was calculated from both echocardiography and CT reconstructions using correlation-based, deviation techniques. The IVS was chosen because it (1) is visible in echocardiography images, whereas the coronary vessels generally are not, and (2) has been shown to be a suitable indicator of cardiac quiescence. Quiescent phases were calculated as the minima of IVS motion and CT volumes were reconstructed for these phases. The diagnostic quality of the CT reconstructions from phases calculated from echocardiography and CT data was graded on a four-point Likert scale by a board-certified radiologist fellowship-trained in cardiothoracic radiology. Using a Wilcoxon signed-rank test, no significant difference in the diagnostic quality of the coronary vessels was found between CT volumes reconstructed from echocardiography- and CT-selected phases. Additionally, there was a correlation of 0.956 between the echocardiography- and CT-selected phases. This initial work suggests that B-mode echocardiography can be used as a tool to develop CT-compatible gating techniques based on modalities derived from cardiac mechanics rather than relying on the ECG alone.

  11. Risk stratification and staging in prostate cancer with prostatic specific membrane antigen PET/CTObjective: A one-stop-shop.

    PubMed

    Gupta, Manoj; Choudhury, Partha Sarathi; Rawal, Sudhir; Goel, Harish Chandra; Singh, Amitabh; Talwar, Vineet; Sahoo, Saroj Kumar

    2017-01-01

    Current imaging modalities for prostate cancer (PC) had limitations for risk stratification and staging. Magnetic resonance imaging (MRI) frequently underestimated lymphatic metastasis while bone scintigraphy often had diagnostic dilemmas. Prostatic specific membrane antigen (PSMA) positron emission tomography-computed tomography (PET/CT) has been remarkable in diagnosing PC recurrence and staging. We hypothesized it can become one-stop-shop for initial risk stratification and staging. Ninety seven PSMA PET-CT studies were re analysed for tumor node metastases (TNM) staging and risk stratification of lymphatic and distant metastases proportion. The histopathology of 23/97 patients was available as gold standard. Chi-square test was used for proportion comparison. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), over-estimation, under-estimation and correct-estimation of T and N stages were calculated. Cohen's kappa coefficient (k) was derived for inter-rater agreement. Lymphic or distant metastases detection on PSMA PET/CT increased significantly with increase in risk category. PSMA PET/CT sensitivity, specificity, PPV and NPV for extra prostatic extension (EPE), seminal vesicle invasion (SVI) and lymphatic metastases were 63.16%, 100%, 100%, 36.36% & 55%, 100%, 100%, 25% and 65.62%, 99.31%, 87.50%, 97.53%, respectively. Cohen's kappa coefficient showed substantial agreement between PSMA PET/CT and histopathological lymphic metastases (κ 0.734) however, it was just in fair agreement (κ 0.277) with T stage. PSMA PET/CT over-estimated, under-estimated and correct-estimated T and N stages in 8.71%, 39.13%, 52.17% and 8.71%, 4.35%, 86.96% cases, respectively. We found that PSMA PET/CT has potential for initial risk stratifications with reasonable correct estimation for N stage. However, it can underestimate T stage. Hence, we suggest that PSMA PET/CT should be used for staging and initial risk stratification of PC as one-stop-shop with regional MRI in surgically resectable cases.

  12. Clinical Application of Dual-Energy Spectral Computed Tomography in Detecting Cholesterol Gallstones From Surrounding Bile.

    PubMed

    Yang, Chuang-Bo; Zhang, Shuang; Jia, Yong-Jun; Duan, Hai-Feng; Ma, Guang-Ming; Zhang, Xi-Rong; Yu, Yong; He, Tai-Ping

    2017-04-01

    This study aimed to investigate the clinical value of spectral computed tomography (CT) in the detection of cholesterol gallstones from surrounding bile. This study was approved by the institutional review board. The unenhanced spectral CT data of 24 patients who had surgically confirmed cholesterol gallstones were analyzed. Lipid concentrations and CT numbers were measured from fat-based material decomposition image and virtual monochromatic image sets (40-140 keV), respectively. The difference in lipid concentration and CT number between cholesterol gallstones and the surrounding bile were statistically analyzed. Receiver operating characteristic analysis was applied to determine the diagnostic accuracy of using lipid concentration to differentiate cholesterol gallstones from bile. Cholesterol gallstones were bright on fat-based material decomposition images yielding a 92% detection rate (22 of 24). The lipid concentrations (552.65 ± 262.36 mg/mL), CT number at 40 keV (-31.57 ± 16.88 HU) and 140 keV (24.30 ± 5.85 HU) for the cholesterol gallstones were significantly different from those of bile (-13.94 ± 105.12 mg/mL, 12.99 ± 9.39 HU and 6.19 ± 4.97 HU, respectively). Using 182.59 mg/mL as the threshold value for lipid concentration, one could obtain sensitivity of 95.5% and specificity of 100% with accuracy of 0.994 for differentiating cholesterol gallstones from bile. Virtual monochromatic spectral CT images at 40 keV and 140 keV provide significant CT number differences between cholesterol gallstones and the surrounding bile. Spectral CT provides an excellent detection rate for cholesterol gallstones. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of the robustness of the preprocessing technique improving reversible compressibility of CT images: Tested on various CT examinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeon, Chang Ho; Kim, Bohyoung; Gu, Bon Seung

    2013-10-15

    Purpose: To modify the preprocessing technique, which was previously proposed, improving compressibility of computed tomography (CT) images to cover the diversity of three dimensional configurations of different body parts and to evaluate the robustness of the technique in terms of segmentation correctness and increase in reversible compression ratio (CR) for various CT examinations.Methods: This study had institutional review board approval with waiver of informed patient consent. A preprocessing technique was previously proposed to improve the compressibility of CT images by replacing pixel values outside the body region with a constant value resulting in maximizing data redundancy. Since the technique wasmore » developed aiming at only chest CT images, the authors modified the segmentation method to cover the diversity of three dimensional configurations of different body parts. The modified version was evaluated as follows. In randomly selected 368 CT examinations (352 787 images), each image was preprocessed by using the modified preprocessing technique. Radiologists visually confirmed whether the segmented region covers the body region or not. The images with and without the preprocessing were reversibly compressed using Joint Photographic Experts Group (JPEG), JPEG2000 two-dimensional (2D), and JPEG2000 three-dimensional (3D) compressions. The percentage increase in CR per examination (CR{sub I}) was measured.Results: The rate of correct segmentation was 100.0% (95% CI: 99.9%, 100.0%) for all the examinations. The median of CR{sub I} were 26.1% (95% CI: 24.9%, 27.1%), 40.2% (38.5%, 41.1%), and 34.5% (32.7%, 36.2%) in JPEG, JPEG2000 2D, and JPEG2000 3D, respectively.Conclusions: In various CT examinations, the modified preprocessing technique can increase in the CR by 25% or more without concerning about degradation of diagnostic information.« less

  14. Cumulative total effective whole-body radiation dose in critically ill patients.

    PubMed

    Rohner, Deborah J; Bennett, Suzanne; Samaratunga, Chandrasiri; Jewell, Elizabeth S; Smith, Jeffrey P; Gaskill-Shipley, Mary; Lisco, Steven J

    2013-11-01

    Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.

  15. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2007-03-01

    Multislice CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multislice CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. Moreover, we have provided diagnostic assistance methods to medical screening specialists by using a lung cancer screening algorithm built into mobile helical CT scanner for the lung cancer mass screening done in the region without the hospital. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.

  16. Accuracy and cost-effectiveness of dynamic contrast-enhanced CT in the characterisation of solitary pulmonary nodules—the SPUtNIk study

    PubMed Central

    Qureshi, N R; Rintoul, R C; Miles, K A; George, S; Harris, S; Madden, J; Cozens, K; Little, L A; Eichhorst, K; Jones, J; Moate, P; McClement, C; Pike, L; Sinclair, D; Wong, W L; Shekhdar, J; Eaton, R; Shah, A; Brindle, L; Peebles, C; Banerjee, A; Dizdarevic, S; Han, S; Poon, F W; Groves, A M; Kurban, L; Frew, A J; Callister, M E; Crosbie, P; Gleeson, F V; Karunasaagarar, K; Kankam, O; Gilbert, F J

    2016-01-01

    Introduction Solitary pulmonary nodules (SPNs) are common on CT. The most cost-effective investigation algorithm is still to be determined. Dynamic contrast-enhanced CT (DCE-CT) is an established diagnostic test not widely available in the UK currently. Methods and analysis The SPUtNIk study will assess the diagnostic accuracy, clinical utility and cost-effectiveness of DCE-CT, alongside the current CT and 18-flurodeoxyglucose-positron emission tomography) (18FDG-PET)-CT nodule characterisation strategies in the National Health Service (NHS). Image acquisition and data analysis for 18FDG-PET-CT and DCE-CT will follow a standardised protocol with central review of 10% to ensure quality assurance. Decision analytic modelling will assess the likely costs and health outcomes resulting from incorporation of DCE-CT into management strategies for patients with SPNs. Ethics and dissemination Approval has been granted by the South West Research Ethics Committee. Ethics reference number 12/SW/0206. The results of the trial will be presented at national and international meetings and published in an Health Technology Assessment (HTA) Monograph and in peer-reviewed journals. Trial registration number ISRCTN30784948; Pre-results. PMID:27843550

  17. Developing patient-specific dose protocols for a CT scanner and exam using diagnostic reference levels.

    PubMed

    Strauss, Keith J

    2014-10-01

    The management of image quality and radiation dose during pediatric CT scanning is dependent on how well one manages the radiographic techniques as a function of the type of exam, type of CT scanner, and patient size. The CT scanner's display of expected CT dose index volume (CTDIvol) after the projection scan provides the operator with a powerful tool prior to the patient scan to identify and manage appropriate CT techniques, provided the department has established appropriate diagnostic reference levels (DRLs). This paper provides a step-by-step process that allows the development of DRLs as a function of type of exam, of actual patient size and of the individual radiation output of each CT scanner in a department. Abdomen, pelvis, thorax and head scans are addressed. Patient sizes from newborns to large adults are discussed. The method addresses every CT scanner regardless of vendor, model or vintage. We cover adjustments to techniques to manage the impact of iterative reconstruction and provide a method to handle all available voltages other than 120 kV. This level of management of CT techniques is necessary to properly monitor radiation dose and image quality during pediatric CT scans.

  18. Selecting children for head CT following head injury

    PubMed Central

    Kemp, A; Nickerson, E; Trefan, L; Houston, R; Hyde, P; Pearson, G; Edwards, R; Parslow, RC; Maconochie, I

    2016-01-01

    Objective Indicators for head CT scan defined by the 2007 National Institute for Health and Care Excellence (NICE) guidelines were analysed to identify CT uptake, influential variables and yield. Design Cross-sectional study. Setting Hospital inpatient units: England, Wales, Northern Ireland and the Channel Islands. Patients Children (<15 years) admitted to hospital for more than 4 h following a head injury (September 2009 to February 2010). Interventions CT scan. Main outcome measures Number of children who had CT, extent to which NICE guidelines were followed and diagnostic yield. Results Data on 5700 children were returned by 90% of eligible hospitals, 84% of whom were admitted to a general hospital. CT scans were performed on 30.4% of children (1734), with a higher diagnostic yield in infants (56.5% (144/255)) than children aged 1 to 14 years (26.5% (391/1476)). Overall, only 40.4% (984 of 2437 children) fulfilling at least one of the four NICE criteria for CT actually underwent one. These children were much less likely to receive CT if admitted to a general hospital than to a specialist centre (OR 0.52 (95% CI 0.45 to 0.59)); there was considerable variation between healthcare regions. When indicated, children >3 years were much more likely to have CT than those <3 years (OR 2.35 (95% CI 2.08 to 2.65)). Conclusion Compliance with guidelines and diagnostic yield was variable across age groups, the type of hospital and region where children were admitted. With this pattern of clinical practice the risks of both missing intracranial injury and overuse of CT are considerable. PMID:27449674

  19. Selecting children for head CT following head injury.

    PubMed

    Kemp, A; Nickerson, E; Trefan, L; Houston, R; Hyde, P; Pearson, G; Edwards, R; Parslow, R C; Maconochie, I

    2016-10-01

    Indicators for head CT scan defined by the 2007 National Institute for Health and Care Excellence (NICE) guidelines were analysed to identify CT uptake, influential variables and yield. Cross-sectional study. Hospital inpatient units: England, Wales, Northern Ireland and the Channel Islands. Children (<15 years) admitted to hospital for more than 4 h following a head injury (September 2009 to February 2010). CT scan. Number of children who had CT, extent to which NICE guidelines were followed and diagnostic yield. Data on 5700 children were returned by 90% of eligible hospitals, 84% of whom were admitted to a general hospital. CT scans were performed on 30.4% of children (1734), with a higher diagnostic yield in infants (56.5% (144/255)) than children aged 1 to 14 years (26.5% (391/1476)). Overall, only 40.4% (984 of 2437 children) fulfilling at least one of the four NICE criteria for CT actually underwent one. These children were much less likely to receive CT if admitted to a general hospital than to a specialist centre (OR 0.52 (95% CI 0.45 to 0.59)); there was considerable variation between healthcare regions. When indicated, children >3 years were much more likely to have CT than those <3 years (OR 2.35 (95% CI 2.08 to 2.65)). Compliance with guidelines and diagnostic yield was variable across age groups, the type of hospital and region where children were admitted. With this pattern of clinical practice the risks of both missing intracranial injury and overuse of CT are considerable. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. FDG-PET/CT can rule out malignancy in patients with vocal cord palsy.

    PubMed

    Thomassen, Anders; Nielsen, Anne Lerberg; Lauridsen, Jeppe Kiilerich; Blomberg, Björn Alexander; Hess, Søren; Petersen, Henrik; Johansen, Allan; Asmussen, Jon Thor; Sørensen, Jesper Roed; Johansen, Jørgen; Godballe, Christian; Høilund-Carlsen, Poul Flemming

    2014-01-01

    The aim was to investigate the performance of (18)F-fluorodeoxyglucose PET/CT to rule out malignancy in patients with confirmed vocal cord palsy (VCP). Between January 2011 and June 2013, we retrospectively included consecutive patients referred to PET/CT with paresis or paralysis of one or both vocal cords. PET/CT results were compared to clinical workup and histopathology. The study comprised 65 patients (32 females) with a mean age of 66±12 years (range 37-89). Eleven patients (17%) had antecedent cancer. Twenty-seven (42%) were diagnosed with cancer during follow-up. The palsy was right-sided in 24 patients, left-sided in 37, and bilateral in 4. Median follow-up was 7 months (interquartile range 4-11 months). Patients without cancer were followed for at least three months. PET/CT suggested a malignancy in 35 patients (27 true positives, 8 false positives) and showed none in 30 (30 true negatives, 0 false negatives). Thus, the sensitivity, specificity, positive and negative predictive values, and accuracy were (95% confidence intervals in parenthesis): 100% (88%-100%), 79% (64%-89%), 77% (61%-88%), 100% (89%-100%), and 88% (78%-94%), respectively. Sixteen patients had palliative treatment, while 11 were treated with curative intent, emphasising the severity of VCP and the need for a rapid and accurate diagnostic work-up. In this retrospective survey, biopsy proven malignancy (whether newly diagnosed or relapsed) was the cause of VCP in almost half of patients (42%). PET/CT had a high sensitivity (100%) with a relatively high false positive rate, but was excellent in ruling out malignancy (negative predictive value 100%).

Top