  1. Radiation dose reduction in chest CT: a review.

    PubMed

    Kubo, Takeshi; Lin, Pei-Jan Paul; Stiller, Wolfram; Takahashi, Masaya; Kauczor, Hans-Ulrich; Ohno, Yoshiharu; Hatabu, Hiroto

    2008-02-01

    This article aims to summarize the available data on reducing radiation dose exposure in routine chest CT protocols. First, the general aspects of radiation dose in CT and radiation risk are discussed, followed by the effect of changing parameters on image quality. Finally, the results of previous radiation dose reduction studies are reviewed, and important information contributing to radiation dose reduction will be shared. A variety of methods and techniques for radiation dose reduction should be used to ensure that radiation exposure is kept as low as is reasonably achievable.

  2. Validation of CT dose-reduction simulation

    SciTech Connect

    Massoumzadeh, Parinaz; Don, Steven; Hildebolt, Charles F.; Bae, Kyongtae T.; Whiting, Bruce R.

    2009-01-15

    The objective of this research was to develop and validate a custom computed tomography dose-reduction simulation technique for producing images that have an appearance consistent with the same scan performed at a lower mAs (with fixed kVp, rotation time, and collimation). Synthetic noise is added to projection (sinogram) data, incorporating a stochastic noise model that includes energy-integrating detectors, tube-current modulation, bowtie beam filtering, and electronic system noise. Experimental methods were developed to determine the parameters required for each component of the noise model. As a validation, the outputs of the simulations were compared to measurements with cadavers in the image domain and with phantoms in both the sinogram and image domain, using an unbiased root-mean-square relative error metric to quantify agreement in noise processes. Four-alternative forced-choice (4AFC) observer studies were conducted to confirm the realistic appearance of simulated noise, and the effects of various system model components on visual noise were studied. The ''just noticeable difference (JND)'' in noise levels was analyzed to determine the sensitivity of observers to changes in noise level. Individual detector measurements were shown to be normally distributed (p>0.54), justifying the use of a Gaussian random noise generator for simulations. Phantom tests showed the ability to match original and simulated noise variance in the sinogram domain to within 5.6%{+-}1.6% (standard deviation), which was then propagated into the image domain with errors less than 4.1%{+-}1.6%. Cadaver measurements indicated that image noise was matched to within 2.6%{+-}2.0%. More importantly, the 4AFC observer studies indicated that the simulated images were realistic, i.e., no detectable difference between simulated and original images (p=0.86) was observed. JND studies indicated that observers' sensitivity to change in noise levels corresponded to a 25% difference in dose, which

  3. Validation of CT dose-reduction simulation

    PubMed Central

    Massoumzadeh, Parinaz; Don, Steven; Hildebolt, Charles F.; Bae, Kyongtae T.; Whiting, Bruce R.

    2009-01-01

    The objective of this research was to develop and validate a custom computed tomography dose-reduction simulation technique for producing images that have an appearance consistent with the same scan performed at a lower mAs (with fixed kVp, rotation time, and collimation). Synthetic noise is added to projection (sinogram) data, incorporating a stochastic noise model that includes energy-integrating detectors, tube-current modulation, bowtie beam filtering, and electronic system noise. Experimental methods were developed to determine the parameters required for each component of the noise model. As a validation, the outputs of the simulations were compared to measurements with cadavers in the image domain and with phantoms in both the sinogram and image domain, using an unbiased root-mean-square relative error metric to quantify agreement in noise processes. Four-alternative forced-choice (4AFC) observer studies were conducted to confirm the realistic appearance of simulated noise, and the effects of various system model components on visual noise were studied. The “just noticeable difference (JND)” in noise levels was analyzed to determine the sensitivity of observers to changes in noise level. Individual detector measurements were shown to be normally distributed (p>0.54), justifying the use of a Gaussian random noise generator for simulations. Phantom tests showed the ability to match original and simulated noise variance in the sinogram domain to within 5.6%±1.6% (standard deviation), which was then propagated into the image domain with errors less than 4.1%±1.6%. Cadaver measurements indicated that image noise was matched to within 2.6%±2.0%. More importantly, the 4AFC observer studies indicated that the simulated images were realistic, i.e., no detectable difference between simulated and original images (p=0.86) was observed. JND studies indicated that observers’ sensitivity to change in noise levels corresponded to a 25% difference in dose, which is

  4. Validation of CT dose-reduction simulation.

    PubMed

    Massoumzadeh, Parinaz; Don, Steven; Hildebolt, Charles F; Bae, Kyongtae T; Whiting, Bruce R

    2009-01-01

    The objective of this research was to develop and validate a custom computed tomography dose-reduction simulation technique for producing images that have an appearance consistent with the same scan performed at a lower mAs (with fixed kVp, rotation time, and collimation). Synthetic noise is added to projection (sinogram) data, incorporating a stochastic noise model that includes energy-integrating detectors, tube-current modulation, bowtie beam filtering, and electronic system noise. Experimental methods were developed to determine the parameters required for each component of the noise model. As a validation, the outputs of the simulations were compared to measurements with cadavers in the image domain and with phantoms in both the sinogram and image domain, using an unbiased root-mean-square relative error metric to quantify agreement in noise processes. Four-alternative forced-choice (4AFC) observer studies were conducted to confirm the realistic appearance of simulated noise, and the effects of various system model components on visual noise were studied. The "just noticeable difference (JND)" in noise levels was analyzed to determine the sensitivity of observers to changes in noise level. Individual detector measurements were shown to be normally distributed (p > 0.54), justifying the use of a Gaussian random noise generator for simulations. Phantom tests showed the ability to match original and simulated noise variance in the sinogram domain to within 5.6% +/- 1.6% (standard deviation), which was then propagated into the image domain with errors less than 4.1% +/- 1.6%. Cadaver measurements indicated that image noise was matched to within 2.6% +/- 2.0%. More importantly, the 4AFC observer studies indicated that the simulated images were realistic, i.e., no detectable difference between simulated and original images (p = 0.86) was observed. JND studies indicated that observers' sensitivity to change in noise levels corresponded to a 25% difference in dose

  5. Radiation dose-reduction strategies in thoracic CT.

    PubMed

    Moser, J B; Sheard, S L; Edyvean, S; Vlahos, I

    2017-05-01

    Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Radiation dose-reduction strategies for neuroradiology CT protocols.

    PubMed

    Smith, A B; Dillon, W P; Gould, R; Wintermark, M

    2007-10-01

    Within the past 2 decades, the number of CT examinations performed has increased almost 10-fold. This is in large part due to advances in multidetector-row CT technology, which now allows faster image acquisition and improved isotropic imaging. The increased use, along with multidetector technique, has led to a significantly increased radiation dose to the patient from CT studies. This places increased responsibility on the radiologist to ensure that CT examinations are indicated and that the "as low as reasonably achievable" concept is adhered to. Neuroradiologists are familiar with factors that affect patient dose such as pitch, milliamperes, kilovolt peak (kVp), collimation, but with increasing attention being given to dose reduction, they are looking for additional ways to further reduce the radiation associated with their CT protocols. In response to increasing concern, CT manufacturers have developed dose-reduction tools, such as dose modulation, in which the tube current is adjusted along with the CT acquisition, according to patient's attenuation. This review will describe the available techniques for reducing dose associated with neuroradiologic CT imaging protocols.

  7. Impact of new technologies on dose reduction in CT.

    PubMed

    Lee, Ting-Yim; Chhem, Rethy K

    2010-10-01

    The introduction of slip ring technology enables helical CT scanning in the late 1980's and has rejuvenated CT's role in diagnostic imaging. Helical CT scanning has made possible whole body scanning in a single breath hold and computed tomography angiography (CTA) which has replaced invasive catheter based angiography in many cases because of its easy of operation and lesser risk to patients. However, a series of recent articles and accidents have heightened the concern of radiation risk from CT scanning. Undoubtedly, the radiation dose from CT studies, in particular, CCTA studies, are among the highest dose studies in diagnostic imaging. Nevertheless, CT has remained the workhorse of diagnostic imaging in emergent and non-emergent situations because of their ubiquitous presence in medical facilities from large academic to small regional hospitals and their round the clock accessibility due to their ease of use for both staff and patients as compared to MR scanners. The legitimate concern of radiation dose has sparked discussions on the risk vs benefit of CT scanning. It is recognized that newer CT applications, like CCTA and perfusion, will be severely curtailed unless radiation dose is reduced. This paper discusses the various hardware and software techniques developed to reduce radiation dose to patients in CT scanning. The current average effective dose of a CT study is ∼10 mSv, with the implementation of dose reduction techniques discussed herein; it is realistic to expect that the average effective dose may be decreased by 2-3 fold. Copyright © 2010. Published by Elsevier Ireland Ltd.

  8. Strategies for reduction of radiation dose in cardiac multislice CT.

    PubMed

    Paul, Jean-François; Abada, Hicham T

    2007-08-01

    Because cardiac computed tomography (CT) (mainly coronary CT angiography) is a very promising technique, used more and more for coronary artery evaluation, the benefits and risks of this new low-invasive technique must be balanced. Radiation dose is a major concern for coronary CT angiography, especially in case of repeated examinations or in particular subgroups of patients (for example young female patients). Radiation dose to patient tends to increase from 16- to 64-slice CT. Radiation exposure in ECG-gated acquisitions may reach up to 40 mSv; considerable differences are attributable to the performance of CT machines, to technical dose-sparing tools, but also to radiological habits. Setting radiation dose at the lowest level possible should be a constant goal for the radiologist. Current technological tools are detailed in regard to their efficiency. Optimisation is necessary, by a judicious use of technological tools and also by individual adaptation of kV or mAs. This paper reviews the different current strategies for radiation dose reduction, keeping image quality constant. Data from the literature are discussed, and future technological developments are considered in regards to radiation dose reduction. The particular case of paediatric patients with congenital heart disease is also addressed.

  9. Radiation dose reduction in multidetector CT in fracture evaluation.

    PubMed

    Yi, Jung Woo; Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Mi Sung

    2017-08-01

    To evaluate whether multidetector CT with low-dose radiation (low-dose CT) of joints can be useful when evaluating fractures. Our study included CT scans of 398 patients, 103 shoulder cases, 109 wrist cases, 98 pelvis cases and 88 ankle cases. There were 191 females and 207 males. The low-dose CTs were performed using identical voltage and parameters with the exception of decreased (half of standard dose) tube current. Low-dose and standard-dose images were compared with regards to objective image quality, subjective evaluation of image quality and diagnostic performance for the fractures. There was no significant difference of image noise between standard-dose CT and low-dose CT in every joint (p > 0.05). Each mean value of subjective score did not show significant difference according to the dosage of the CT scan. There were no statistically significant differences in the sensitivity (96-100%), specificity (95.2-100%) or accuracy (97.9-100%) between standard-dose CT and low-dose CT (p values, 0.1336-1.000). The evaluation of extremities for fractures using low-dose CT can reduce radiation exposure by about 50% compared with standard-dose CT without affecting image quality or diagnostic performance. Advances in knowledge: Low-dose CT of the extremities (shoulder, pelvis, ankle and wrist) can reduce radiation dose by about 50% compared with standard-dose CT and does not significantly affect image quality or diagnostic performance in fracture detection.

  10. Radiation dose reduction in parasinus CT by spectral shaping.

    PubMed

    May, Matthias S; Brand, Michael; Lell, Michael M; Sedlmair, Martin; Allmendinger, Thomas; Uder, Michael; Wuest, Wolfgang

    2017-02-01

    Spectral shaping aims to narrow the X-ray spectrum of clinical CT. The aim of this study was to determine the image quality and the extent of radiation dose reduction that can be achieved by tin prefiltration for parasinus CT. All scans were performed with a third generation dual-source CT scanner. A study protocol was designed using 100 kV tube voltage with tin prefiltration (200 mAs) that provides image noise levels comparable to a low-dose reference protocol using 100 kV without spectral shaping (25 mAs). One hundred consecutive patients were prospectively enrolled and randomly assigned to the study or control group. All patients signed written informed consent. The study protocol was approved by the local Institutional Review Board and applies to the HIPAA. Subjective and objective image quality (attenuation values, image noise, and contrast-to-noise ratio (CNR)) were assessed. Radiation exposure was assessed as volumetric CT dose index, and effective dose was estimated. Mann-Whitney U test was performed for radiation exposure and for image noise comparison. All scans were of diagnostic image quality. Image noise in air, in the retrobulbar fat, and in the eye globe was comparable between both groups (all p > 0.05). CNReye globe/air did not differ significantly between both groups (p = 0.7). Radiation exposure (1.7 vs. 2.1 mGy, p < 0.01) and effective dose (0.055 vs. 0.066 mSv, p < 0.01) were significantly reduced in the study group. Radiation dose can be further reduced by 17% for low-dose parasinus CT by tin prefiltration maintaining diagnostic image quality.

  11. Patient specific tube current modulation for CT dose reduction

    NASA Astrophysics Data System (ADS)

    Jin, Yannan; Yin, Zhye; Yao, Yangyang; Wang, Hui; Wu, Mingye; Kalra, Mannudeep; De Man, Bruno

    2015-03-01

    Radiation exposure during CT imaging has drawn growing concern from academia, industry as well as the general public. Sinusoidal tube current modulation has been available in most commercial products and used routinely in clinical practice. To further exploit the potential of tube current modulation, Sperl et al. proposed a Computer-Assisted Scan Protocol and Reconstruction (CASPAR) scheme [6] that modulates the tube current based on the clinical applications and patient specific information. The purpose of this study is to accelerate the CASPAR scheme to make it more practical for clinical use and investigate its dose benefit for different clinical applications. The Monte Carlo simulation in the original CASPAR scheme was substituted by the dose reconstruction to accelerate the optimization process. To demonstrate the dose benefit, we used the CATSIM package generate the projection data and perform standard FDK reconstruction. The NCAT phantom at thorax position was used in the simulation. We chose three clinical cases (routine chest scan, coronary CT angiography with and without breast avoidance) and compared the dose level with different mA modulation schemes (patient specific, sinusoidal and constant mA) with matched image quality. The simulation study of three clinical cases demonstrated that the patient specific mA modulation could significantly reduce the radiation dose compared to sinusoidal modulation. The dose benefits depend on the clinical application and object shape. With matched image quality, for chest scan the patient specific mA profile reduced the dose by about 15% compared to the sinusoid mA modulation; for the organ avoidance scan the dose reduction to the breast was over 50% compared to the constant mA baseline.

  12. Radiation dose reduction for coronary artery calcium scoring at 320-detector CT with adaptive iterative dose reduction 3D.

    PubMed

    Tatsugami, Fuminari; Higaki, Toru; Fukumoto, Wataru; Kaichi, Yoko; Fujioka, Chikako; Kiguchi, Masao; Yamamoto, Hideya; Kihara, Yasuki; Awai, Kazuo

    2015-06-01

    To assess the possibility of reducing the radiation dose for coronary artery calcium (CAC) scoring by using adaptive iterative dose reduction 3D (AIDR 3D) on a 320-detector CT scanner. Fifty-four patients underwent routine- and low-dose CT for CAC scoring. Low-dose CT was performed at one-third of the tube current used for routine-dose CT. Routine-dose CT was reconstructed with filtered back projection (FBP) and low-dose CT was reconstructed with AIDR 3D. We compared the calculated Agatston-, volume-, and mass scores of these images. The overall percentage difference in the Agatston-, volume-, and mass scores between routine- and low-dose CT studies was 15.9, 11.6, and 12.6%, respectively. There were no significant differences in the routine- and low-dose CT studies irrespective of the scoring algorithms applied. The CAC measurements of both imaging modalities were highly correlated with respect to the Agatston- (r = 0.996), volume- (r = 0.996), and mass score (r = 0.997; p < 0.001, all); the Bland-Altman limits of agreement scores were -37.4 to 51.4, -31.2 to 36.4 and -30.3 to 40.9%, respectively, suggesting that AIDR 3D was a good alternative for FBP. The mean effective radiation dose for routine- and low-dose CT was 2.2 and 0.7 mSv, respectively. The use of AIDR 3D made it possible to reduce the radiation dose by 67% for CAC scoring without impairing the quantification of coronary calcification.

  13. Estimation of breast dose reduction potential for organ-based tube current modulated CT with wide dose reduction arc

    NASA Astrophysics Data System (ADS)

    Fu, Wanyi; Sturgeon, Gregory M.; Agasthya, Greeshma; Segars, W. Paul; Kapadia, Anuj J.; Samei, Ehsan

    2017-03-01

    This study aimed to estimate the organ dose reduction potential for organ-dose-based tube current modulated (ODM) thoracic CT with wide dose reduction arc. Twenty-one computational anthropomorphic phantoms (XCAT, age range: 27- 75 years, weight range: 52.0-105.8 kg) were used to create a virtual patient population with clinical anatomic variations. For each phantom, two breast tissue compositions were simulated: 50/50 and 20/80 (glandular-to-adipose ratio). A validated Monte Carlo program was used to estimate the organ dose for standard tube current modulation (TCM) (SmartmA, GE Healthcare) and ODM (GE Healthcare) for a commercial CT scanner (Revolution, GE Healthcare) with explicitly modeled tube current modulation profile, scanner geometry, bowtie filtration, and source spectrum. Organ dose was determined using a typical clinical thoracic CT protocol. Both organ dose and CTDIvol-to-organ dose conversion coefficients (h factors) were compared between TCM and ODM. ODM significantly reduced all radiosensitive organ doses (p<0.01). The breast dose was reduced by 30+/-2%. For h factors, organs in the anterior region (e.g. thyroid, stomach) exhibited substantial decreases, and the medial, distributed, and posterior region either saw an increase or no significant change. The organ-dose-based tube current modulation significantly reduced organ doses especially for radiosensitive superficial anterior organs such as the breasts.

  14. Multidetector CT in children: current concepts and dose reduction strategies

    PubMed Central

    van Dam, Ingrid M.; van der Molen, Aart J.

    2010-01-01

    The recent technical development of multidetector CT (MDCT) has contributed to a substantial increase in its diagnostic applications and accuracy in children. A major drawback of MDCT is the use of ionising radiation with the risk of inducing secondary cancer. Therefore, justification and optimisation of paediatric MDCT is of great importance in order to minimise these risks (“as low as reasonably achievable” principle). This review will focus on all technical and non-technical aspects relevant for paediatric MDCT optimisation and includes guidelines for radiation dose level-based CT protocols. PMID:20535463

  15. Multidetector CT in children: current concepts and dose reduction strategies.

    PubMed

    Nievelstein, Rutger A J; van Dam, Ingrid M; van der Molen, Aart J

    2010-08-01

    The recent technical development of multidetector CT (MDCT) has contributed to a substantial increase in its diagnostic applications and accuracy in children. A major drawback of MDCT is the use of ionising radiation with the risk of inducing secondary cancer. Therefore, justification and optimisation of paediatric MDCT is of great importance in order to minimise these risks ("as low as reasonably achievable" principle). This review will focus on all technical and non-technical aspects relevant for paediatric MDCT optimisation and includes guidelines for radiation dose level-based CT protocols.

  16. Securing safe and informative thoracic CT examinations-Progress of radiation dose reduction techniques.

    PubMed

    Kubo, Takeshi; Ohno, Yoshiharu; Seo, Joon Beom; Yamashiro, Tsuneo; Kalender, Willi A; Lee, Chang Hyun; Lynch, David A; Kauczor, Hans-Ulrich; Hatabu, Hiroto

    2017-01-01

    The increase in the radiation exposure from CT examinations prompted the investigation on the various dose-reduction techniques. Significant dose reduction has been achieved and the level of radiation exposure of thoracic CT is expected to reach the level equivalent to several chest X-ray examinations. With more scanners with advanced dose reduction capability deployed, knowledge on the radiation dose reduction methods has become essential to clinical practice as well as academic research. This article reviews the history of dose reduction techniques, ongoing changes brought by newer technologies and areas of further investigation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT

    SciTech Connect

    Manduca, Armando; Yu Lifeng; Trzasko, Joshua D.; Khaylova, Natalia; Kofler, James M.; McCollough, Cynthia M.; Fletcher, Joel G.

    2009-11-15

    -off than a series of commercial reconstruction kernels. This improvement in noise-resolution properties can be used for improving image quality in CT and can be translated into substantial dose reduction.

  18. Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT.

    PubMed

    Manduca, Armando; Yu, Lifeng; Trzasko, Joshua D; Khaylova, Natalia; Kofler, James M; McCollough, Cynthia M; Fletcher, Joel G

    2009-11-01

    reconstruction kernels. This improvement in noise-resolution properties can be used for improving image quality in CT and can be translated into substantial dose reduction.

  19. Radiation dose reduction in chest CT--review of available options.

    PubMed

    Kubo, Takeshi; Ohno, Yoshiharu; Kauczor, Hans Ulrich; Hatabu, Hiroto

    2014-10-01

    Computed tomography currently accounts for the majority of radiation exposure related to medical imaging. Although technological improvement of CT scanners has reduced the radiation dose of individual examinations, the benefit was overshadowed by the rapid increase in the number of CT examinations. Radiation exposure from CT examination should be kept as low as reasonably possible for patient safety. Measures to avoid inappropriate CT examinations are needed. Principles and information on radiation dose reduction in chest CT are reviewed in this article. The reduction of tube current and tube potential are the mainstays of dose reduction methods. Study results indicate that routine protocols with reduced tube current are feasible with diagnostic results comparable to conventional standard dose protocols. Tube current adjustment is facilitated by the advent of automatic tube current modulation systems by setting the appropriate image quality level for the purpose of the examination. Tube potential reduction is an effective method for CT pulmonary angiography. Tube potential reduction often requires higher tube current for satisfactory image quality, but may still contribute to significant radiation dose reduction. Use of lower tube potential also has considerable advantage for smaller patients. Improvement in image production, especially the introduction of iterative reconstruction methods, is expected to lower radiation dose significantly. Radiation dose reduction in CT is a multifaceted issue. Understanding these aspects leads to an optimal solution for various indications of chest CT. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Efficacy of high-pitch CT protocols for radiation dose reduction.

    PubMed

    Guberina, N; Lechel, U; Forsting, M; Ringelstein, A

    2016-12-01

    Various strategies have been developed to reduce radiation exposure of patients in CT examinations. The aim of this study was to evaluate the efficacy of high pitch in representative CT protocols examining lung embolism. We performed thermoluminescence measurements with an anthropomorphic phantom exposing it to CT algorithms for lung embolism in a 128-multislice, dual-source CT scanner: a standard CT protocol (sCT) and a CT protocol with a high pitch (+ F). Radiation doses for both CT algorithms were compared and the dose reduction potential of high pitch for individual organs was evaluated. As expected, the  +F mode reduced the effective dose and organ doses in the primary beam of radiation (namely, lung, bone marrow, heart, breast, skin and skeleton) compared with sCT by up to 52% for an equivalent image quality. On the contrary, for organs at the margin of the primary beam (thymus, thyroid, liver, pancreas, kidneys, colon and small intestine), the  +F mode reduced effective radiation doses by only 0-30%, compared with sCT. The dose reduction potential of the  +F mode greatly depends on the position of the organ in the scan field. While for organs in the primary beam  + F leads to a considerable dose reduction, it is less effective for tissues at the margin of the scanned area.

  1. Ultra-Low-Dose CT of the Thorax Using Iterative Reconstruction: Evaluation of Image Quality and Radiation Dose Reduction.

    PubMed

    Kim, Yookyung; Kim, Yoon Kyung; Lee, Bo Eun; Lee, Seok Jeong; Ryu, Yon Ju; Lee, Jin Hwa; Chang, Jung Hyun

    2015-06-01

    The purpose of this study is to assess the image quality and radiation dose reduction of ultra-low-dose CT using sinogram-affirmed iterative reconstruction (SAFIRE). This prospective study enrolled 25 patients who underwent three consecutive unenhanced CT scans including low-dose CT (120 kVp and 30 mAs) and two ultra-low-dose CT protocols (protocol A, 100 kVp and 20 mAs; protocol B, 80 kVp and 30 mAs) with image reconstruction using SAFIRE. The image quality and radiation dose reduction were assessed. The mean (± SD) effective radiation dose was 1.06 ± 0.11, 0.44 ± 0.05, and 0.31 ± 0.03 mSv for low-dose CT, ultra-low-dose CT protocol A, and ultra-low-dose CT protocol B, respectively. Overall image quality was determined as diagnostic in 100% of low-dose CT scans, 96% of ultra-low-dose CT protocol A scans, and 88% of ultra-low-dose CT protocol B scans. All patients with nondiagnostic quality images had a body mass index (weight in kilograms divided by the square of height in meters) greater than 25. There was no statistically significant difference in detection frequencies of 14 lesion types among the three CT protocols, but pulmonary emphysema was detected in fewer patients (3/25) in ultra-low-dose CT protocol B scans compared with ultra-low-dose CT protocol A scans (5/25) or low-dose CT scans (6/25). We measured the longest dimensions of 33 small solid nodules (3.8-12.4 mm in long diameter) and found no statistically significant difference in the values afforded by the three CT protocols (p = 0.135). Iterative reconstruction allows ultra-low-dose CT and affords acceptable image quality, allowing size measurements of solid pulmonary nodules to be made.

  2. Quality initiatives: CT radiation dose reduction: how to implement change without sacrificing diagnostic quality.

    PubMed

    Tamm, Eric P; Rong, X John; Cody, Dianna D; Ernst, Randy D; Fitzgerald, Nancy E; Kundra, Vikas

    2011-01-01

    The risks and benefits of using computed tomography (CT) as opposed to another imaging modality to accomplish a particular clinical goal should be weighed carefully. To accurately assess radiation risks and keep radiation doses as low as reasonably achievable, radiologists must be knowledgeable about the doses delivered during various types of CT studies performed at their institutions. The authors of this article propose a process improvement approach that includes the estimation of effective radiation dose levels, formulation of dose reduction goals, modification of acquisition protocols, assessment of effects on image quality, and implementation of changes necessary to ensure quality. A first step toward developing informed radiation dose reduction goals is to become familiar with the radiation dose values and radiation-associated health risks reported in the literature. Next, to determine the baseline dose values for a CT study at a particular institution, dose data can be collected from the CT scanners, interpreted, tabulated, and graphed. CT protocols can be modified to reduce overall effective dose by using techniques such as automated exposure control and iterative reconstruction, as well as by decreasing the number of scanning phases, increasing the section thickness, and adjusting the peak voltage (kVp setting), tube current-time product (milliampere-seconds), and pitch. Last, PDSA (plan, do, study, act) cycles can be established to detect and minimize negative effects of dose reduction methods on image quality.

  3. Objective assessment of image quality and dose reduction in CT iterative reconstruction

    SciTech Connect

    Vaishnav, J. Y. Jung, W. C.; Popescu, L. M.; Zeng, R.; Myers, K. J.

    2014-07-15

    Purpose: Iterative reconstruction (IR) algorithms have the potential to reduce radiation dose in CT diagnostic imaging. As these algorithms become available on the market, a standardizable method of quantifying the dose reduction that a particular IR method can achieve would be valuable. Such a method would assist manufacturers in making promotional claims about dose reduction, buyers in comparing different devices, physicists in independently validating the claims, and the United States Food and Drug Administration in regulating the labeling of CT devices. However, the nonlinear nature of commercially available IR algorithms poses challenges to objectively assessing image quality, a necessary step in establishing the amount of dose reduction that a given IR algorithm can achieve without compromising that image quality. This review paper seeks to consolidate information relevant to objectively assessing the quality of CT IR images, and thereby measuring the level of dose reduction that a given IR algorithm can achieve. Methods: The authors discuss task-based methods for assessing the quality of CT IR images and evaluating dose reduction. Results: The authors explain and review recent literature on signal detection and localization tasks in CT IR image quality assessment, the design of an appropriate phantom for these tasks, possible choices of observers (including human and model observers), and methods of evaluating observer performance. Conclusions: Standardizing the measurement of dose reduction is a problem of broad interest to the CT community and to public health. A necessary step in the process is the objective assessment of CT image quality, for which various task-based methods may be suitable. This paper attempts to consolidate recent literature that is relevant to the development and implementation of task-based methods for the assessment of CT IR image quality.

  4. CT-guided brachytherapy of prostate cancer: reduction of effective dose from X-ray examination

    NASA Astrophysics Data System (ADS)

    Sanin, Dmitriy B.; Biryukov, Vitaliy A.; Rusetskiy, Sergey S.; Sviridov, Pavel V.; Volodina, Tatiana V.

    2014-03-01

    Computed tomography (CT) is one of the most effective and informative diagnostic method. Though the number of CT scans among all radiographic procedures in the USA and European countries is 11% and 4% respectively, CT makes the highest contribution to the collective effective dose from all radiographic procedures, it is 67% in the USA and 40% in European countries [1-5]. Therefore it is necessary to understand the significance of dose value from CT imaging to a patient . Though CT dose from multiple scans and potential risk is of great concern in pediatric patients, this applies to adults as well. In this connection it is very important to develop optimal approaches to dose reduction and optimization of CT examination. International Commission on Radiological Protection (ICRP) in its publications recommends radiologists to be aware that often CT image quality is higher than it is necessary for diagnostic confidence[6], and there is a potential to reduce the dose which patient gets from CT examination [7]. In recent years many procedures, such as minimally invasive surgery, biopsy, brachytherapy and different types of ablation are carried out under guidance of computed tomography [6;7], and during a procedures multiple CT scans focusing on a specific anatomic region are performed. At the Clinics of MRRC different types of treatment for patients with prostate cancer are used, incuding conformal CT-guided brachytherapy, implantation of microsources of I into the gland under guidance of spiral CT [8]. So, the purpose of the study is to choose optimal method to reduce radiation dose from CT during CT-guided prostate brachytherapy and to obtain the image of desired quality.

  5. Dose reduction in chest CT: comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques.

    PubMed

    Yamada, Yoshitake; Jinzaki, Masahiro; Hosokawa, Takahiro; Tanami, Yutaka; Sugiura, Hiroaki; Abe, Takayuki; Kuribayashi, Sachio

    2012-12-01

    To assess the effectiveness of adaptive iterative dose reduction (AIDR) and AIDR 3D in improving the image quality in low-dose chest CT (LDCT). Fifty patients underwent standard-dose chest CT (SDCT) and LDCT simultaneously, performed under automatic exposure control with noise index of 19 and 38 (for a 2-mm slice thickness), respectively. The SDCT images were reconstructed with filtered back projection (SDCT-FBP images), and the LDCT images with FBP, AIDR and AIDR 3D (LDCT-FBP, LDCT-AIDR and LDCT-AIDR 3D images, respectively). On all the 200 lung and 200 mediastinal image series, objective image noise and signal-to-noise ratio (SNR) were measured in several regions, and two blinded radiologists independently assessed the subjective image quality. Wilcoxon's signed rank sum test with Bonferroni's correction was used for the statistical analyses. The mean dose reduction in LDCT was 64.2% as compared with the dose in SDCT. LDCT-AIDR 3D images showed significantly reduced objective noise and significantly increased SNR in all regions as compared to the SDCT-FBP, LDCT-FBP and LDCT-AIDR images (all, P ≤ 0.003). In all assessments of the image quality, LDCT-AIDR 3D images were superior to LDCT-AIDR and LDCT-FBP images. The overall diagnostic acceptability of both the lung and mediastinal LDCT-AIDR 3D images was comparable to that of the lung and mediastinal SDCT-FBP images. AIDR 3D is superior to AIDR. Intra-individual comparisons between SDCT and LDCT suggest that AIDR 3D allows a 64.2% reduction of the radiation dose as compared to SDCT, by substantially reducing the objective image noise and increasing the SNR, while maintaining the overall diagnostic acceptability. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Radiation dose reduction in perfusion CT imaging of the brain: A review of the literature.

    PubMed

    Othman, Ahmed E; Afat, Saif; Brockmann, Marc A; Nikoubashman, Omid; Brockmann, Carolin; Nikolaou, Konstantin; Wiesmann, Martin

    2016-02-01

    Perfusion CT (PCT) of the brain is widely used in the settings of acute ischemic stroke and vasospasm monitoring. The high radiation dose associated with PCT is a central topic and has been a focus of interest for many researchers. Many studies have examined the effect of radiation dose reduction in PCT using different approaches. Reduction of tube current and tube voltage can be efficient and lead to a remarkable reduction of effective radiation dose while preserving acceptable image quality. The use of novel noise reduction techniques such as iterative reconstruction or spatiotemporal smoothing can produce sufficient image quality from low-dose perfusion protocols. Reduction of sampling frequency of perfusion images has only little potential to reduce radiation dose. In the present article we aimed to summarize the available data on radiation dose reduction in PCT imaging of the brain. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. [Application of adaptive iterative dose reduction technique in CT enterography in diagnosing Crohn disease].

    PubMed

    Lian, Yanbang; Cao, Wuteng; Zhu, Shanshan; Lin, Yanghao; Liu, Dechao; Wang, Xinhua; Qiu, Jianping; Zhou, Zhiyang

    2014-07-01

    To evaluate the application of low-dose CT enterography with adaptive iterative dose reduction(AIDR) technique in diagnosing Crohn's disease. Retrospective analysis was performed on 26 patients diagnosed as Crohn's disease by the multidisciplinary team in our hospital. Low-dose CT enterography with 640-slice MDCT was performed on these 26 patients using adaptive iterative dose reduction(AIDR) technique. Characteristics of Crohn's disease in CT enterography images were independently analyzed by two radiologists who were experienced in Crohn's disease with calculating the total radiation dosage. The radiation dosage of 26 patients ranged from 5.58 to 12.90 [mean (9.00±2.00)] mSv, which was lower than conventional scan (around 15 mSv) known from the literatures. According to the images of CT enterography of 26 cases, bowel wall thickening with abnormal enhancement and lymphadenectasis were found in 25 cases with total 109 segmental bowel wall thickening. Among 25 thickening cases, enterostenosis was found in 16 cases, stratification enhancement in 12 cases and comb sign in 14 cases. Besides, it was found that 8 cases with hyperdense fat on the mesenteric side, 7 cases with intestinal fistula, 6 cases with abdominal cavity abscess, and 3 cases with anal fistula. CT enterography of Crohn's disease with adaptive iterative dose reduction technique is an effective method to evaluate Crohn's disease without compromising image quality with reduced radiation dosage.

  8. SparseCT: interrupted-beam acquisition and sparse reconstruction for radiation dose reduction

    NASA Astrophysics Data System (ADS)

    Koesters, Thomas; Knoll, Florian; Sodickson, Aaron; Sodickson, Daniel K.; Otazo, Ricardo

    2017-03-01

    State-of-the-art low-dose CT methods reduce the x-ray tube current and use iterative reconstruction methods to denoise the resulting images. However, due to compromises between denoising and image quality, only moderate dose reductions up to 30-40% are accepted in clinical practice. An alternative approach is to reduce the number of x-ray projections and use compressed sensing to reconstruct the full-tube-current undersampled data. This idea was recognized in the early days of compressed sensing and proposals for CT dose reduction appeared soon afterwards. However, no practical means of undersampling has yet been demonstrated in the challenging environment of a rapidly rotating CT gantry. In this work, we propose a moving multislit collimator as a practical incoherent undersampling scheme for compressed sensing CT and evaluate its application for radiation dose reduction. The proposed collimator is composed of narrow slits and moves linearly along the slice dimension (z), to interrupt the incident beam in different slices for each x-ray tube angle (θ). The reduced projection dataset is then reconstructed using a sparse approach, where 3D image gradients are employed to enforce sparsity. The effects of the collimator slits on the beam profile were measured and represented as a continuous slice profile. SparseCT was tested using retrospective undersampling and compared against commercial current-reduction techniques on phantoms and in vivo studies. Initial results suggest that SparseCT may enable higher performance than current-reduction, particularly for high dose reduction factors.

  9. Radiation dose during CT-guided percutaneous cryoablation of renal tumors: Effect of a dose reduction protocol.

    PubMed

    Levesque, Vincent M; Shyn, Paul B; Tuncali, Kemal; Tatli, Servet; Nawfel, Richard D; Olubiyi, Olutayo; Silverman, Stuart G

    2015-11-01

    To estimate and compare the radiation dose using a standard protocol and that of a dose reduction protocol in patients undergoing CT-guided percutaneous cryoablation of renal tumors. An IRB-approved, HIPAA-compliant retrospective study of 97 CT-guided cryoablation procedures to treat a solitary renal tumor in each of 97 patients (64 M, 33 F; range 31-84 yrs) was performed. Fifty patients were treated using a standard dose protocol (kVp=120, mean mAs=180, monitoring scans every 3 min during freezes), and an additional 47 patients were treated using a dose reduction protocol (kVp=100, mean mAs=100, monitoring scans less frequently than every 3 min during freezes). Multiple Wilcoxon Mann-Whitney (rank-sum) tests were used to compare dose-length product (DLP) between the two groups. Fisher's exact test was used to compare technique effectiveness at 12 months post ablation between the two groups. Median DLP for the standard protocol group was 4833.5 mGy*cm (range, 1667-8267 mGy*cm); median DLP for the dose reduction group was 2648 mGy*cm (range, 850-7169 mGy*cm), significantly less than that of the standard protocol group (p<0.01). The technique effectiveness for the dose reduction group was not significantly different from that of the standard protocol group at 12 month follow up (p=0.434). The radiation dose during percutaneous CT-guided cryoablation of renal tumors was substantial in both the standard and the dose reduction groups; however, it was significantly lower with the protocol change that reduced dose parameters and decreased the number of CT scans. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Breast dose reduction with organ-based, wide-angle tube current modulated CT.

    PubMed

    Fu, Wanyi; Sturgeon, Gregory M; Agasthya, Greeshma; Segars, William Paul; Kapadia, Anuj J; Samei, Ehsan

    2017-07-01

    This study aimed to estimate the organ dose reduction potential for organ-dose-based tube current modulated (ODM) thoracic computed tomography (CT) with a wide dose reduction arc. Twenty-one computational anthropomorphic phantoms (XCAT) were used to create a virtual patient population with clinical anatomic variations. The phantoms were created based on patient images with normal anatomy (age range: 27 to 66 years, weight range: 52.0 to 105.8 kg). For each phantom, two breast tissue compositions were simulated: [Formula: see text] and [Formula: see text] (glandular-to-adipose ratio). A validated Monte Carlo program (PENELOPE, Universitat de Barcelona, Spain) was used to estimate the organ dose for standard tube current modulation (TCM) (SmartmA, GE Healthcare) and ODM (GE Healthcare) for a commercial CT scanner (Revolution, GE Healthcare) using a typical clinical thoracic CT protocol. Both organ dose and [Formula: see text]-to-organ dose conversion coefficients ([Formula: see text] factors) were compared between TCM and ODM. ODM significantly reduced all radiosensitive organ doses ([Formula: see text]). The breast dose was reduced by [Formula: see text]. For [Formula: see text] factors, organs in the anterior region (e.g., thyroid and stomach) exhibited substantial decreases, and the medial, distributed, and posterior region saw either an increase of less than 5% or no significant change. ODM significantly reduced organ doses especially for radiosensitive superficial anterior organs such as the breasts.

  11. Evaluation of dose reduction and image quality in CT colonography: comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection.

    PubMed

    Nagata, Koichi; Fujiwara, Masanori; Kanazawa, Hidenori; Mogi, Tomohiro; Iida, Nao; Mitsushima, Toru; Lefor, Alan T; Sugimoto, Hideharu

    2015-01-01

    To prospectively evaluate the radiation dose and image quality comparing low-dose CT colonography (CTC) reconstructed using different levels of iterative reconstruction techniques with routine-dose CTC reconstructed with filtered back projection. Following institutional ethics clearance and informed consent procedures, 210 patients underwent screening CTC using automatic tube current modulation for dual positions. Examinations were performed in the supine position with a routine-dose protocol and in the prone position, randomly applying four different low-dose protocols. Supine images were reconstructed with filtered back projection and prone images with iterative reconstruction. Two blinded observers assessed the image quality of endoluminal images. Image noise was quantitatively assessed by region-of-interest measurements. The mean effective dose in the supine series was 1.88 mSv using routine-dose CTC, compared to 0.92, 0.69, 0.57, and 0.46 mSv at four different low doses in the prone series (p < 0.01). Overall image quality and noise of low-dose CTC with iterative reconstruction were significantly improved compared to routine-dose CTC using filtered back projection. The lowest dose group had image quality comparable to routine-dose images. Low-dose CTC with iterative reconstruction reduces the radiation dose by 48.5 to 75.1% without image quality degradation compared to routine-dose CTC with filtered back projection. • Low-dose CTC reduces radiation dose ≥ 48.5% compared to routine-dose CTC. • Iterative reconstruction improves overall CTC image quality compared with FBP. • Iterative reconstruction reduces overall CTC image noise compared with FBP. • Automated exposure control with iterative reconstruction is useful for low-dose CTC.

  12. Working Face-to-Face for Pediatric CT Dose Reduction: A Community Toolkit

    PubMed Central

    Armao, Diane; Hartman, Terry; Shea, Christopher M.; Sams, Cassandra; Fordham, Lynn Ansley; Smith, J. Keith

    2016-01-01

    Although children are especially vulnerable to the health risks of ionizing radiation, approximately 8 million CTs are performed on children in the USA. Widespread dose variation is common, particularly in non-pediatric focused facilities. In this article we present our rationale and hands-on approach in developing and refining a toolkit aimed at helping a community hospital with pediatric CT dose reduction. PMID:27942250

  13. Potential of combining iterative reconstruction with noise efficient detector design: aggressive dose reduction in head CT

    PubMed Central

    Bender, B; Schabel, C; Fenchel, M; Ernemann, U; Korn, A

    2015-01-01

    Objective: With further increase of CT numbers and their dominant contribution to medical exposure, there is a recent quest for more effective dose control. While reintroduction of iterative reconstruction (IR) has proved its potential in many applications, a novel focus is placed on more noise efficient detectors. Our purpose was to assess the potential of IR in combination with an integrated circuit detector (ICD) for aggressive dose reduction in head CT. Methods: Non-contrast low-dose head CT [190 mAs; weighted volume CT dose index (CTDIvol), 33.2 mGy] was performed in 50 consecutive patients, using a new noise efficient detector and IR. Images were assessed in terms of quantitative and qualitative image quality and compared with standard dose acquisitions (320 mAs; CTDIvol, 59.7 mGy) using a conventional detector and filtered back projection. Results: By combining ICD and IR in low-dose examinations, the signal to noise was improved by about 13% above the baseline level in the standard-dose control group. Both, contrast-to-noise ratio (2.02 ± 0.6 vs 1.88 ± 0.4; p = 0.18) and objective measurements of image sharpness (695 ± 84 vs 705 ± 151 change in Hounsfield units per pixel; p = 0.79) were fully preserved in the low-dose group. Likewise, there was no significant difference in the grading of several subjective image quality parameters when both noise-reducing strategies were used in low-dose examinations. Conclusion: Combination of noise efficient detector with IR allows for meaningful dose reduction in head CT without compromise of standard image quality. Advances in knowledge: Our study demonstrates the feasibility of almost 50% dose reduction in head CT dose (1.1 mSv per scan) through combination of novel dose-reducing strategies. PMID:25827204

  14. Radiation dose reduction in CT myocardial perfusion imaging using SMART-RECON.

    PubMed

    Li, Yinsheng; Speidel, Michael A; Francois, Christopher J; Chen, Guang-Hong

    2017-08-30

    In this work, a newly developed statistical model based image reconstruction (referred to as Simultaneous Multiple Artifacts Reduction in Tomographic RECONstruction (SMARTRECON) [1]) is applied to low dose computer tomography (CT) myocardial perfusion imaging (CT-MPI). This method uses the nuclear norm of the spatial-temporal image matrix of the CTMPI images as a regularizer, rather than a conventional spatial regularizer that incorporates image smoothness, edge preservation, or spatial sparsity into the reconstruction. In addition to providing the needed noise reduction for low-dose CT-MPI, SMART-RECON provides images with spatial resolution and noise power spectrum (NPS) properties which are independent of contrast and dose level. Both numerical simulations and in vivo animal studies were performed to validate the proposed method. In these studies, it was found that: (1) Quantitative accuracy of perfusion maps in CT-MPI was well maintained for radiation dose level as low as 10 mAs per image frame, compared with the reference standard of 200 mAs for conventional filtered backprojection (FBP); (2) Flow-occluded myocardium in the porcine heart was well delineated by SMART-RECON at 10 mAs per frame when compared with MBIR using spatial total variation (TV) as the regularizer (referred to as TV-SIR) or Spatial-Temporal TV (ST-TV-SIR); The CT-MPI results were confirmed with PET imaging; (3) Image sharpness in SMARTRECON images was nearly independent of image contrast level and radiation dose level, in stark contrast to TV-SIR and STTV- SIR which displayed a strong dependence on both image contrast and radiation dose level; (4) The structure of the dosenormalized NPS for the SMART-RECON method did not depend on dose, while the TV-SIR and ST-TV-SIR NPS structure was dose-dependent.

  15. Radiation dose reduction in time-resolved CT angiography using highly constrained back projection reconstruction

    PubMed Central

    Supanich, Mark; Tao, Yinghua; Nett, Brian; Pulfer, Kari; Hsieh, Jiang; Turski, Patrick; Mistretta, Charles; Rowley, Howard; Chen, Guang-Hong

    2010-01-01

    Recently dynamic, time-resolved three-dimensional computed tomography angiography (CTA) has been introduced to the neurological imaging community. However, the radiation dose delivered to patients in time-resolved CTA protocol is a high and potential risk associated with the ionizing radiation dose. Thus, minimizing the radiation dose is highly desirable for time-resolved CTA. In order to reduce the radiation dose delivered during dynamic, contrast-enhanced CT applications, we introduce here the CT formulation of HighlY constrained back PRojection (HYPR) imaging. We explore the radiation dose reduction approaches of both acquiring a reduced number of projections for each image and lowering the tube current used during acquisition. We then apply HYPR image reconstruction to produce image sets at a reduced patient dose and with low image noise. Numerical phantom experiments and retrospective analysis of in vivo canine studies are used to assess the accuracy and quality of HYPR reduced dose image sets and validate our approach. Experimental results demonstrated that a factor of 6–8 times radiation dose reduction is possible when the HYPR algorithm is applied to time-resolved CTA exams. PMID:19567941

  16. Radiation Dose Reduction in Paranasal Sinus CT: With Feasibility of Iterative Reconstruction Technique.

    PubMed

    Bang, Minseo; Choi, Seong Hoon; Park, Jongha; Kang, Byeong Seong; Kwon, Woon Jung; Lee, Tae Hoon; Nam, Jung Gwon

    2016-12-01

    To (1) compare the radiation dose of low-dose computed tomography (CT) to that of standard-dose CT, (2) determine the minimum optimal radiation dose for use in patients who need endoscopic sinus surgery, and (3) assess the reliability of iterative model reconstruction. Prospective single-institution study. Tertiary care center. We recruited 48 adults with medically refractory sinusitis. Each patient underwent 4 scans with different CT parameters: 120 kV and 100 mAs (standard dose), 100 kV and 40 mAs (low dose), 100 kV and 20 mAs (very low dose), and 100 kV and 10 mAs (ultra-low dose). All CT scans were reconstructed via filtered back-projection, and ultra-low dose scans were additionally reconstructed through iterative model reconstruction. Radiation dose, image quality, and diagnostic performance were compared among the scans. Radiation doses decreased to 6% (ultra-low dose), 12% (very low dose), and 22% (low dose) of the standard-dose CT. The image quality of low-dose CT was similar to that of standard-dose CT. Ultra-low-dose CT with iterative model reconstruction was inferior to standard-dose CT for identifying anatomic structures, except for the optic nerve. All CT scans had 100% agreement for diagnosing rhinosinusitis. With low-dose CT, the radiation dose can be decreased to 22% of that of standard-dose CT without affecting the image quality. Low-dose CT can be considered the minimum optimal radiation for patients who need surgery. Iterative model reconstruction is not useful for assessing the anatomic details of the paranasal sinus on CT. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  17. Impact of view reduction in CT on radiation dose for patients

    NASA Astrophysics Data System (ADS)

    Parcero, E.; Flores, L.; Sánchez, M. G.; Vidal, V.; Verdú, G.

    2017-08-01

    Iterative methods have become a hot topic of research in computed tomography (CT) imaging because of their capacity to resolve the reconstruction problem from a limited number of projections. This allows the reduction of radiation exposure on patients during the data acquisition. The reconstruction time and the high radiation dose imposed on patients are the two major drawbacks in CT. To solve them effectively we adapted the method for sparse linear equations and sparse least squares (LSQR) with soft threshold filtering (STF) and the fast iterative shrinkage-thresholding algorithm (FISTA) to computed tomography reconstruction. The feasibility of the proposed methods is demonstrated numerically.

  18. Thyroid shields versus z-axis automatic tube current modulation for dose reduction at neck CT.

    PubMed

    Leswick, David A; Hunt, Megan M; Webster, Steven T; Fladeland, Derek A

    2008-11-01

    To assess the effectiveness of in-plane bismuth thyroid shields and a z-axis automatic tube current modulation (ATCM) technique with respect to dose reduction and image noise in the thyroid and other regional tissues during neck computed tomography (CT). Because this was a phantom study, neither institutional review board approval nor HIPAA compliance was required. A female phantom, thyroid shields, and an eight-section CT scanner were used. Radiation dose was measured by using thermoluminescent dosimetry (TLD) chips placed in the phantom's thyroid, cervical bone marrow, and soft tissues. Scans were performed by using fixed tube current and a z-axis ATCM technique with and without shields. Image noise was quantified as the standard deviation of the attenuation value (in Hounsfield units) on CT images. Thyroid dose was 76.9 mGy with an unshielded fixed tube current technique. Use of shields and ATCM reduced this dose to 44.7 mGy (42% reduction, P < .001) and 17.0 mGy (78% reduction, P < .001), respectively. The combination of shields and ATCM further reduced this dose to between 11.9 and 12.9 mGy (83%-85% reduction, P < .001), depending on the shield's presence in the scout scan. ATCM resulted in minimized tube current throughout the neck, which reduced dose-length product across the entire scan volume by 60% (926 vs 368 mGy . cm). Thyroid bed noise was lowest (3.9 HU) during the fixed tube current technique without shields, with noise slightly higher (6.9 HU) with the unshielded ATCM technique (P < .001). Thyroid image noise was markedly higher when using shields (P < .001), with noise measuring between 74 and 113 HU for fixed tube current and ATCM scans. z-Axis ATCM is more effective than shields at reducing thyroid radiation dose during neck CT. Shields combined with ATCM slightly further reduces dose; however, this is associated with higher image noise. (c) RSNA, 2008.

  19. Effects of radiation dose reduction in Volume Perfusion CT imaging of acute ischemic stroke.

    PubMed

    Othman, Ahmed E; Brockmann, Carolin; Yang, Zepa; Kim, Changwon; Afat, Saif; Pjontek, Rastislav; Nikobashman, Omid; Brockmann, Marc A; Kim, Jong Hyo; Wiesmann, Martin

    2015-12-01

    To examine the influence of radiation dose reduction on image quality and sensitivity of Volume Perfusion CT (VPCT) maps regarding the detection of ischemic brain lesions. VPCT data of 20 patients with suspected ischemic stroke acquired at 80 kV and 180 mAs were included. Using realistic reduced-dose simulation, low-dose VPCT datasets with 144 mAs, 108 mAs, 72 mAs and 36 mAs (80 %, 60 %, 40 % and 20 % of the original levels) were generated, resulting in a total of 100 datasets. Perfusion maps were created and signal-to-noise-ratio (SNR) measurements were performed. Qualitative analyses were conducted by two blinded readers, who also assessed the presence/absence of ischemic lesions and scored CBV and CBF maps using a modified ASPECTS-score. SNR of all low-dose datasets were significantly lower than those of the original datasets (p < .05). All datasets down to 72 mAs (40 %) yielded sufficient image quality and high sensitivity with excellent inter-observer-agreements, whereas 36 mAs datasets (20 %) yielded poor image quality in 15 % of the cases with lower sensitivity and inter-observer-agreements. Low-dose VPCT using decreased tube currents down to 72 mAs (40 % of original radiation dose) produces sufficient perfusion maps for the detection of ischemic brain lesions. • Perfusion CT is highly accurate for the detection of ischemic brain lesions • Perfusion CT results in high radiation exposure, therefore low-dose protocols are required • Reduction of tube current down to 72 mAs produces sufficient perfusion maps.

  20. Dose reduction and image quality optimizations in CT of pediatric and adult patients: phantom studies

    NASA Astrophysics Data System (ADS)

    Jeon, P.-H.; Lee, C.-L.; Kim, D.-H.; Lee, Y.-J.; Jeon, S.-S.; Kim, H.-J.

    2014-03-01

    Multi-detector computed tomography (MDCT) can be used to easily and rapidly perform numerous acquisitions, possibly leading to a marked increase in the radiation dose to individual patients. Technical options dedicated to automatically adjusting the acquisition parameters according to the patient's size are of specific interest in pediatric radiology. A constant tube potential reduction can be achieved for adults and children, while maintaining a constant detector energy fluence. To evaluate radiation dose, the weighted CT dose index (CTDIw) was calculated based on the CT dose index (CTDI) measured using an ion chamber, and image noise and image contrast were measured from a scanned image to evaluate image quality. The dose-weighted contrast-to-noise ratio (CNRD) was calculated from the radiation dose, image noise, and image contrast measured from a scanned image. The noise derivative (ND) is a quality index for dose efficiency. X-ray spectra with tube voltages ranging from 80 to 140 kVp were used to compute the average photon energy. Image contrast and the corresponding contrast-to-noise ratio (CNR) were determined for lesions of soft tissue, muscle, bone, and iodine relative to a uniform water background, as the iodine contrast increases at lower energy (i.e., k-edge of iodine is 33 keV closer to the beam energy) using mixed water-iodine contrast normalization (water 0, iodine 25, 100, 200, and 1000 HU, respectively). The proposed values correspond to high quality images and can be reduced if only high-contrast organs are assessed. The potential benefit of lowering the tube voltage is an improved CNRD, resulting in a lower radiation dose and optimization of image quality. Adjusting the tube potential in abdominal CT would be useful in current pediatric radiography, where the choice of X-ray techniques generally takes into account the size of the patient as well as the need to balance the conflicting requirements of diagnostic image quality and radiation dose

  1. Quantifying potential reduction in contrast dose with monoenergetic images synthesized from duallayer detector spectral CT.

    PubMed

    Tsang, Derek S; Merchant, Thomas E; Merchant, Sophie E; Smith, Hanna; Yagil, Yoad; Hua, Chia-Ho

    2017-07-27

    To estimate the potential dose reduction in iodinated contrast when interpreting monoenergetic images from spectral CT. 51 pediatric patients received contrast-enhanced CT simulation for radiation therapy using a single-source, dual-layer detector spectral CT. The contrast-to-noise ratios (CNR) of blood vessels were measured relative to surrounding soft tissue. CNRs on monoenergetic 40-70 keV images were compared with polychromatic 120 kVp images. To compare with in vivo results, a phantom with iodine inserts (2-20 mg/mL concentration) was scanned and CNRs were calculated relative to water background. Monoenergetic keV and body site had significant effects on CNR ratio (P < 0.0001). Across all body sites, the mean CNR ratio (monoenergetic/polychromatic CNR) was 3.3 (20(th) percentile [%20] 2.6), 2.4 (%20 2.1), 1.7 (%20 1.5), 1.2 (%20 1.0) for 40, 50, 60 and 70 keV images, respectively. Image noise was highest at 40 keV and lowest at 70 keV. Phantom measurements indicated that the same CNR as 120 kVp images can be achieved with a 4.0-fold lower iodine concentration on 40 keV images and 2.5-fold lower on 50 keV images. 50 keV monoenergetic images provided the best balance of improved CNR on all studies (mean 2.4-fold increase in vivo) for enhancing vessels versus image noise. A 50% reduction in contrast dose on a 50 keV image should maintain comparable or better CNR as compared with polychromatic CT in over 80% of CT studies. Advances in Knowledge: Use of a novel, single-source, dual-layer detector spectral CT scanner to improve visualization of contrast-enhanced blood vessels will reduce the amount of iodinated contrast required for radiation oncology treatment planning.

  2. Dose reduction with iterative reconstruction for coronary CT angiography: a systematic review and meta-analysis

    PubMed Central

    Willemink, Martin J; De Ruiter, Quirina M B; De Jong, Pim A; Schilham, Arnold M R; Krestin, Gabriel P; Leiner, Tim; Budde, Ricardo P J

    2016-01-01

    Objective: To investigate the achievable radiation dose reduction for coronary CT angiography (CCTA) with iterative reconstruction (IR) in adults and the effects on image quality. Methods: PubMed and EMBASE were searched, and original articles concerning IR for CCTA in adults using prospective electrocardiogram triggering were included. Primary outcome was the effective dose using filtered back projection (FBP) and IR. Secondary outcome was the effect of IR on objective and subjective image quality. Results: The search yielded 1616 unique articles, of which 10 studies (1042 patients) were included. The pooled routine effective dose with FBP was 4.2 mSv [95% confidence interval (CI) 3.5–5.0]. A dose reduction of 48% to a pooled effective dose of 2.2 mSv (95% CI 1.3–3.1) using IR was reported. Noise, contrast-to-noise ratio and subjective image quality were equal or improved in all but one study, whereas signal-to-noise ratio was decreased in two studies with IR at reduced dose. Conclusion: IR allows for CCTA acquisition with an effective dose of 2.2 mSv with preserved objective and subjective image quality. PMID:26562096

  3. Marked reduction of effective radiation dose in patients undergoing CT coronary angiography using prospective ECG gating.

    PubMed

    Freeman, Anthony; Learner, Ruth; Eggleton, Simon; Lambros, John; Friedman, Daniel

    2011-08-01

    Coronary CT angiography (CCTA) is a rapidly evolving technology which can characterise and image sub clinical atherosclerotic plaque and visualise anatomy and quantitate stenosis. Concern about radiation exposure has limited the uptake of this technology. The aim of this study was to review the radiation dose data in 2298 consecutive patients referred to a single centre in an Australian outpatient setting over 27 months using all available radiation dose reduction strategies. Prospective ECG gating ("step and shoot") was used preferentially in 2025 patients with a mean effective dose of 3.39 ± 1.84 mSv (range 0.86-12.6 mSv). For clinical reasons only 273 patients required retrospective ECG gating, mean dose 19.21 ± 5.58 mSv (range 2.4-34.9 mSv) resulting in an 85.7% reduction in dose for the majority of patients with the low dose technique. In conclusion, most patients referred for routine CCTA can be studied with a radiation dose comparable to invasive X-ray angiography and less than radionuclide myocardial perfusion imaging. Copyright © 2011 Australasian Society of Cardiac and Thoracic Surgeons and the Cardiac Society of Australia and New Zealand. Published by Elsevier B.V. All rights reserved.

  4. Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective

    SciTech Connect

    Brady, S. L.; Yee, B. S.; Kaufman, R. A.

    2012-09-15

    Purpose: This study demonstrates a means of implementing an adaptive statistical iterative reconstruction (ASiR Trade-Mark-Sign ) technique for dose reduction in computed tomography (CT) while maintaining similar noise levels in the reconstructed image. The effects of image quality and noise texture were assessed at all implementation levels of ASiR Trade-Mark-Sign . Empirically derived dose reduction limits were established for ASiR Trade-Mark-Sign for imaging of the trunk for a pediatric oncology population ranging from 1 yr old through adolescence/adulthood. Methods: Image quality was assessed using metrics established by the American College of Radiology (ACR) CT accreditation program. Each image quality metric was tested using the ACR CT phantom with 0%-100% ASiR Trade-Mark-Sign blended with filtered back projection (FBP) reconstructed images. Additionally, the noise power spectrum (NPS) was calculated for three common reconstruction filters of the trunk. The empirically derived limitations on ASiR Trade-Mark-Sign implementation for dose reduction were assessed using (1, 5, 10) yr old and adolescent/adult anthropomorphic phantoms. To assess dose reduction limits, the phantoms were scanned in increments of increased noise index (decrementing mA using automatic tube current modulation) balanced with ASiR Trade-Mark-Sign reconstruction to maintain noise equivalence of the 0% ASiR Trade-Mark-Sign image. Results: The ASiR Trade-Mark-Sign algorithm did not produce any unfavorable effects on image quality as assessed by ACR criteria. Conversely, low-contrast resolution was found to improve due to the reduction of noise in the reconstructed images. NPS calculations demonstrated that images with lower frequency noise had lower noise variance and coarser graininess at progressively higher percentages of ASiR Trade-Mark-Sign reconstruction; and in spite of the similar magnitudes of noise, the image reconstructed with 50% or more ASiR Trade-Mark-Sign presented a more

  5. Noise reduction with low dose CT data based on a modified ROF model.

    PubMed

    Zhu, Yining; Zhao, Mengliu; Zhao, Yunsong; Li, Hongwei; Zhang, Peng

    2012-07-30

    In order to reduce the radiation exposure caused by Computed Tomography (CT) scanning, low dose CT has gained much interest in research as well as in industry. One fundamental difficulty for low dose CT lies in its heavy noise pollution in the raw data which leads to quality deterioration for reconstructed images. In this paper, we propose a modified ROF model to denoise low dose CT measurement data in light of Poisson noise model. Experimental results indicate that the reconstructed CT images based on measurement data processed by our model are in better quality, compared to the original ROF model or bilateral filtering.

  6. Influence of dose reduction and iterative reconstruction on CT calcium scores: a multi-manufacturer dynamic phantom study.

    PubMed

    van der Werf, N R; Willemink, M J; Willems, T P; Greuter, M J W; Leiner, T

    2017-01-19

    To evaluate the influence of dose reduction in combination with iterative reconstruction (IR) on coronary calcium scores (CCS) in a dynamic phantom on state-of-the-art CT systems from different manufacturers. Calcified inserts in an anthropomorphic chest phantom were translated at 20 mm/s corresponding to heart rates between 60 and 75 bpm. The inserts were scanned five times with routinely used CCS protocols at reference dose and 40 and 80% dose reduction on four high-end CT systems. Filtered back projection (FBP) and increasing levels of IR were applied. Noise levels were determined. CCS, quantified as Agatston and mass scores, were compared to physical mass and scores at FBP reference dose. For the reference dose in combination with FBP, noise level variation between CT systems was less than 18%. Decreasing dose almost always resulted in increased CCS, while at increased levels of IR, CCS decreased again. The influence of IR on CCS was smaller than the influence of dose reduction. At reference dose, physical mass was underestimated 3-30%. All CT systems showed similar CCS at 40% dose reduction in combinations with specific reconstructions. For some CT systems CCS was not affected at 80% dose reduction, in combination with IR. This multivendor study showed that radiation dose reductions of 40% did not influence CCS in a dynamic phantom using state-of-the-art CT systems in combination with specific reconstruction settings. Dose reduction resulted in increased noise and consequently increased CCS, whereas increased IR resulted in decreased CCS.

  7. Dose reduction in CT urography and vasculature phantom studies using model-based iterative reconstruction.

    PubMed

    Page, Leland; Wei, Wei; Kundra, Vikas; Rong, John

    2016-11-08

    To evaluate the feasibility of radiation dose reduction using model-based iterative reconstruction (MBIR) for evaluating the ureters and vasculature in a phantom, a tissue-equivalent CT dose phantom was scanned using a 64-channel CT scan-ner. Tubes of varying diameters filled with different dilutions of a contrast agent, simulating ureters or vessels, were inserted into the center of the phantom. Each combination was scanned using an existing renal protocol at 140 kVp or 120 kVp, yielding a display volumetric CT dose index (CTDIvol) of 24 mGy. The scans were repeated using reduced scan techniques to achieve lower radiation doses down to 0.8 mGy. The images were reconstructed using filtered back-projection (FBP) and model-based iterative reconstruction (MBIR). The noise and contrast-to-noise ratio (CNR) was measured for each contrast object. Comparisons between the two reconstruction methods at different dose levels were evaluated using a factorial design. At each CTDIvol the measured image noise was lower using MBIR compared to FBP (p < 0.0001). At low doses, the percent change in measured image noise between FBP and MBIR was larger. For the 12 mm object simulating a ureter or large vessel with an HU of 600, the measured CNR using MBIR at a CTDIvol of 1.7 mGy was greater than the CNR of FBP at a CTIDvol of 24 mGy (p < 0.0001). For the 5 mm object simulating a medium-sized vessel with a HU of 250, the mea-sured CNR using MBIR at a CTDIvol of 1.7 mGy was equivalent to that of FBP at a CTDIvol of 24 mGy. For the 2 mm, 100 HU object simulating a small vessel, the measured CNR using MBIR at a CTDIvol of 1.7 mGy was equivalent to that of FBP at a CTDIvol of 24 mGy. Low-dose (3.6 mGy) CT imaging of vasculature and ureter phantoms using MBIR results in similar noise and CNR compared to FBP at approximately one-sixth the dose. This suggests that, using MBIR, a one milliSievert exam of the ureters and vasculature may be clinically possible whilst still maintaining adequate

  8. Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction.

    PubMed

    Fahimian, Benjamin P; Zhao, Yunzhe; Huang, Zhifeng; Fung, Russell; Mao, Yu; Zhu, Chun; Khatonabadi, Maryam; DeMarco, John J; Osher, Stanley J; McNitt-Gray, Michael F; Miao, Jianwei

    2013-03-01

    A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). In each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest scanner flux setting of 39 m

  9. A method for patient dose reduction in dynamic contrast enhanced CT study

    SciTech Connect

    Mo Kim, Sun; Haider, Masoom A.; Milosevic, Michael; Jaffray, David A.; Yeung, Ivan W. T.

    2011-09-15

    Purpose: In dynamic contrast enhanced CT (DCE-CT) study, prolonged CT scanning with high temporal resolution is required to give accurate and precise estimates of kinetic parameters. However, such scanning protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce radiation dose to patient, while maintaining high accuracy for kinetic parameter estimates in DCE-CT study. Methods: The method is based on a previous investigation that the arterial impulse response (AIR) in DCE-CT study can be predicted using a population-based scheme. In the proposed method, DCE-CT scanning is performed with relatively low temporal resolution, hence, giving rise to reduction in patient dose. A novel method is proposed to estimate the arterial input function (AIF) based on the coarsely sampled AIF. By using the estimated AIF in the tracer kinetic analysis of the coarsely sampled DCE-CT study, the calculated kinetic parameters are able to achieve a high degree of accuracy. The method was tested on a DCE-CT data set of 48 patients with cervical cancer scanned at high temporal resolution. A random cohort of 34 patients was chosen to construct the orthonormal bases of the AIRs via singular value decomposition method. The determined set of orthonormal bases was used to fit the AIFs in the second cohort (14 patients) at varying levels of down sampling. For each dataset in the second cohort, the estimated AIF was used for kinetic analyses of the modified Tofts and adiabatic tissue homogeneity models for each of the down-sampling schemes between intervals from 2 to 15 s. The results were compared with analyses done with the ''raw'' down-sampled AIF. Results: In the first group of 34 patients, there were 11 orthonormal bases identified to describe the AIRs. The AIFs in the second group were estimated in high accuracy based on the 11 orthonormal bases established in the first group along with down-sampled AIFs. Using the 11 orthonormal bases, the

  10. Automatic selection of tube potential for radiation dose reduction in CT: A general strategy

    SciTech Connect

    Yu Lifeng; Li Hua; Fletcher, Joel G.; McCollough, Cynthia H.

    2010-01-15

    Purpose: To optimize radiation dose efficiency in CT while maintaining image quality, it is important to select the optimal tube potential. The selection of optimal tube potential, however, is highly dependent on patient size and diagnostic task. The purpose of this work was to develop a general strategy that allows for automatic tube potential selection for each individual patient and each diagnostic task. Methods: The authors propose a general strategy that allows automatic adaptation of the tube potential as a function of patient size and diagnostic task, using a novel index of image quality, ''iodine contrast to noise ratio with a noise constraint (iCNR{sub N}C),'' to characterize the different image quality requirements by various clinical applications. The relative dose factor (RDF) at each tube potential to achieve a target image quality was then determined as a function of patient size and the noise constraint parameter. A workflow was developed to automatically identify the optimal tube potential that is both dose efficient and practically feasible, incorporating patient size and diagnostic task. An experimental study using a series of semianthropomorphic thoracic phantoms was used to demonstrate how the proposed general strategy can be implemented and how the radiation dose reduction achievable by the tube potential selection depends on phantom sizes and noise constraint parameters. Results: The proposed strategy provides a flexible and quantitative way to select the optimal tube potential based on the patient size and diagnostic task. The noise constraint parameter {alpha} can be adapted for different clinical applications. For example, {alpha}=1 for noncontrast routine exams; {alpha}=1.1-1.25 for contrast-enhanced routine exams; and {alpha}=1.5-2.0 for CT angiography. For the five thoracic phantoms in the experiment, when {alpha}=1, the optimal tube potentials were 80, 100, 100, 120, 120, respectively. The corresponding RDFs (relative to 120 kV) were 78

  11. Dose reduction for cardiac CT using a registration-based approach

    SciTech Connect

    Wierzbicki, Marcin; Guiraudon, Gerard M.; Jones, Douglas L.; Peters, Terry

    2007-06-15

    Two reasons for the recent rise in radiation exposure from CT are increases in its clinical applicability and the desire to maintain high SNR while acquiring smaller voxels. To address this emerging dose problem, several strategies for reducing patient exposure have already been proposed. One method employed in cardiac imaging is ECG-driven modulation of the tube current between 100% at one time point in the cardiac cycle and a reduced fraction at the remaining phases. In this paper, we describe how images obtained during such acquisition can be used to reconstruct 4D data of consistent high quality throughout the cardiac cycle. In our approach, we assume that the mid-diastole (MD) phase is imaged with full dose. The MD image is then independently registered to lower dose images (lower SNR) at other frames, resulting in a set of transformations. Finally, the transformations are used to warp the MD frame through the cardiac cycle to generate the full 4D image. In addition, the transformations may be interpolated to increase the temporal sampling or to generate images at arbitrary time points. Our approach was validated using various data obtained with simulated and scanner-implemented dose modulation. We determined that as little as 10% of the total dose was required to reproduce full quality images with a 1 mm spatial error and an error in intensity values on the order of the image noise. Thus, our technique offers considerable dose reductions compared to standard imaging protocols, with minimal effects on the quality of the final data.

  12. Dose reduction for cardiac CT using a registration-based approach.

    PubMed

    Wierzbicki, Marcin; Guiraudon, Gérard M; Jones, Douglas L; Peters, Terry

    2007-06-01

    Two reasons for the recent rise in radiation exposure from CT are increases in its clinical applicability and the desire to maintain high SNR while acquiring smaller voxels. To address this emerging dose problem, several strategies for reducing patient exposure have already been proposed. One method employed in cardiac imaging is ECG-driven modulation of the tube current between 100% at one time point in the cardiac cycle and a reduced fraction at the remaining phases. In this paper, we describe how images obtained during such acquisition can be used to reconstruct 4D data of consistent high quality throughout the cardiac cycle. In our approach, we assume that the middiastole (MD) phase is imaged with full dose. The MD image is then independently registered to lower dose images (lower SNR) at other frames, resulting in a set of transformations. Finally, the transformations are used to warp the MD frame through the cardiac cycle to generate the full 4D image. In addition, the transformations may be interpolated to increase the temporal sampling or to generate images at arbitrary time points. Our approach was validated using various data obtained with simulated and scanner-implemented dose modulation. We determined that as little as 10% of the total dose was required to reproduce full quality images with a 1 mm spatial error and an error in intensity values on the order of the image noise. Thus, our technique offers considerable dose reductions compared to standard imaging protocols, with minimal effects on the quality of the final data.

  13. Performance evaluation of iterative reconstruction algorithms for achieving CT radiation dose reduction - a phantom study.

    PubMed

    Dodge, Cristina T; Tamm, Eric P; Cody, Dianna D; Liu, Xinming; Jensen, Corey T; Wei, Wei; Kundra, Vikas; Rong, X John

    2016-03-08

    The purpose of this study was to characterize image quality and dose performance with GE CT iterative reconstruction techniques, adaptive statistical iterative recontruction (ASiR), and model-based iterative reconstruction (MBIR), over a range of typical to low-dose intervals using the Catphan 600 and the anthropomorphic Kyoto Kagaku abdomen phantoms. The scope of the project was to quantitatively describe the advantages and limitations of these approaches. The Catphan 600 phantom, supplemented with a fat-equivalent oval ring, was scanned using a GE Discovery HD750 scanner at 120 kVp, 0.8 s rotation time, and pitch factors of 0.516, 0.984, and 1.375. The mA was selected for each pitch factor to achieve CTDIvol values of 24, 18, 12, 6, 3, 2, and 1 mGy. Images were reconstructed at 2.5 mm thickness with filtered back-projection (FBP); 20%, 40%, and 70% ASiR; and MBIR. The potential for dose reduction and low-contrast detectability were evaluated from noise and contrast-to-noise ratio (CNR) measurements in the CTP 404 module of the Catphan. Hounsfield units (HUs) of several materials were evaluated from the cylinder inserts in the CTP 404 module, and the modulation transfer function (MTF) was calculated from the air insert. The results were con-firmed in the anthropomorphic Kyoto Kagaku abdomen phantom at 6, 3, 2, and 1mGy. MBIR reduced noise levels five-fold and increased CNR by a factor of five compared to FBP below 6mGy CTDIvol, resulting in a substantial improvement in image quality. Compared to ASiR and FBP, HU in images reconstructed with MBIR were consistently lower, and this discrepancy was reversed by higher pitch factors in some materials. MBIR improved the conspicuity of the high-contrast spatial resolution bar pattern, and MTF quantification confirmed the superior spatial resolution performance of MBIR versus FBP and ASiR at higher dose levels. While ASiR and FBP were relatively insensitive to changes in dose and pitch, the spatial resolution for MBIR

  14. New noise reduction method for reducing CT scan dose: Combining Wiener filtering and edge detection algorithm

    NASA Astrophysics Data System (ADS)

    Anam, Choirul; Haryanto, Freddy; Widita, Rena; Arif, Idam

    2015-09-01

    New noise reduction method for reducing dose of CT scans has been proposed. The new method is expected to address the major problems in the noise reduction algorithm, i.e. the decreasing in the spatial resolution of the image. The proposed method was developed by combining adaptive Wiener filtering and edge detection algorithms. The first step, the image was filtered with a Wiener filter. Separately, edge detection operation performed on the original image using the Prewitt method. The next step, a new image was generated based on the edge detection operation. At the edge area, the image was taken from the original image, while at the non-edge area, the image was taken from the image that had been filtered with a Wiener filter. The new method was tested on a CT image of the spatial resolution phantom, which was scanned by different current-time multiplication, namely 80, 130 and 200 mAs, while other exposure factors were kept in constant conditions. The spatial resolution phantom consists of six sets of bar pattern made of plexi-glass and separated at some distance by water. The new image quality assessed from the amount of noise and the magnitude of spatial resolution. Noise was calculated by determining the standard deviation of the homogeneous regions, while the spatial resolution was assessed by observation of the area sets of the bar pattern. In addition, to evaluate the performance of this new method has also been tested on patient CT images. From the measurements, the new method can reduce the noise to an average 64.85%, with a spatial resolution does not decrease significantly. Visually, the third set bar on the image phantom (the distance between the bar 1.0 mm) can still be distinguished, as well as on the original image. Meanwhile, if the image is only processed using Wiener filter, the second set bar (the distance between the bar 1.3 mm) are distinguishable. Testing this new method to patient image, its results in relatively the same. Thus, using this

  15. ACR White Paper-Based Comprehensive Dose Reduction Initiative Is Associated With a Reversal of the Upward Trend in Radiation Dose for Chest CT.

    PubMed

    Rawat, Udit; Cohen, Stuart L; Levsky, Jeffrey M; Haramati, Linda B

    2015-12-01

    In 2010, the authors' department implemented a comprehensive dose reduction strategy based on the ACR white paper on radiation dose in medicine. The aim of this study was to evaluate the effectiveness of the dose reduction program. In total, 1,234 adult chest CT scans from 2007 to 2012 were analyzed retrospectively, with institutional review board approval and a waiver of the requirement for informed consent. The primary outcome was effective dose in millisieverts during the three-year periods before (2007-2009) and after (2010-2012) dose reduction implementation. Dose trends were analyzed by fitted linear modeling. The use and effects on total exposure of dose reduction strategies (high pitch, adaptive statistical iterative reconstruction [ASIR], and low tube voltage) were analyzed. The overall mean dose for chest CT was 7.3 ± 5.1 mSv. The mean dose decreased by 30%, from 9.2 mSv (2007-2009) to 6.5 mSv (2010-2012) (P < .001). From 2007 to 2009, the mean dose increased by 1.2 mSv per year (P < .01). From 2010 to 2012, the mean dose decreased by 1.1 mSv per year (P < 0.01). High-pitch technique, ASIR, and low tube voltage increased significantly after dose reduction implementation. High pitch and ASIR were significantly associated with a reduced dose, whereas the effect of reduced voltage was not significant. Reductions in radiation exposure from medical imaging rely on ongoing technical developments and consistent, vigilant use of dose reduction strategies. This comprehensive dose reduction strategy significantly reduced radiation exposure from chest CT. Annual increases in radiation dose reversed after the strategy was implemented and continued to decline over the study period. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Effect of topogram-tube angle combination on CT radiation dose reduction

    NASA Astrophysics Data System (ADS)

    Shim, J.; Yoon, M.

    2017-09-01

    This study assessed the ability of various types of topograms, when used with an automatic tube current modulation (ATCM) technique, to reduce radiation dose from computed tomography (CT) scans. Three types of topograms were used with the ATCM technique: (i) anteroposterior (AP) topograms alone, (ii) AP topograms followed by lateral topograms, and (iii) lateral topograms followed by AP topograms. Various regions (chest, abdomen and whole-body) of a humanoid phantom were scanned at several tube voltages (80, 100 and 120 kVp) with the selected topograms. Although the CT dose depended on the order of topograms, the CT dose with respect to patient positioning depended on the number of topograms performed. The magnitude of the difference in CT dose between number and order of topograms was greater for the scans of the abdomen than the chest. These results suggest that, for the Siemens SOMATOM Definition AS CT scanner, choosing the right combination of CT scan conditions with the ATCM technique can minimize radiation dose to a patient.

  17. Cardiovascular CT angiography in neonates and children: image quality and potential for radiation dose reduction with iterative image reconstruction techniques.

    PubMed

    Tricarico, Francesco; Hlavacek, Anthony M; Schoepf, U Joseph; Ebersberger, Ullrich; Nance, John W; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J Reid; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Schoenberg, Stefan O; Bonomo, Lorenzo; Apfaltrer, Paul

    2013-05-01

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. • Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. • Using half traditional radiation dose image quality is higher with iterative reconstruction. • Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.

  18. Study of the radiation dose reduction capability of a CT reconstruction algorithm: LCD performance assessment using mathematical model observers

    NASA Astrophysics Data System (ADS)

    Fan, Jiahua; Tseng, Hsin-Wu; Kupinski, Matthew; Cao, Guangzhi; Sainath, Paavana; Hsieh, Jiang

    2013-03-01

    Radiation dose on patient has become a major concern today for Computed Tomography (CT) imaging in clinical practice. Various hardware and algorithm solutions have been designed to reduce dose. Among them, iterative reconstruction (IR) has been widely expected to be an effective dose reduction approach for CT. However, there is no clear understanding on the exact amount of dose saving an IR approach can offer for various clinical applications. We know that quantitative image quality assessment should be task-based. This work applied mathematical model observers to study detectability performance of CT scan data reconstructed using an advanced IR approach as well as the conventional filtered back-projection (FBP) approach. The purpose of this work is to establish a practical and robust approach for CT IR detectability image quality evaluation and to assess the dose saving capability of the IR method under study. Low contrast (LC) objects imbedded in head size and body size phantoms were imaged multiple times with different dose levels. Independent signal present and absent pairs were generated for model observer study training and testing. Receiver Operating Characteristic (ROC) curves for location known exact and location ROC (LROC) curves for location unknown as well as their corresponding the area under the curve (AUC) values were calculated. Results showed approximately 3 times dose reduction has been achieved using the IR method under study.

  19. Adaptive iterative dose reduction (AIDR) 3D in low dose CT abdomen-pelvis: Effects on image quality and radiation exposure

    NASA Astrophysics Data System (ADS)

    Ang, W. C.; Hashim, S.; Karim, M. K. A.; Bahruddin, N. A.; Salehhon, N.; Musa, Y.

    2017-05-01

    The widespread use of computed tomography (CT) has increased the medical radiation exposure and cancer risk. We aimed to evaluate the impact of AIDR 3D in CT abdomen-pelvic examinations based on image quality and radiation dose in low dose (LD) setting compared to standard dose (STD) with filtered back projection (FBP) reconstruction. We retrospectively reviewed the images of 40 patients who underwent CT abdomen-pelvic using a 80 slice CT scanner. Group 1 patients (n=20, mean age 41 ± 17 years) were performed at LD with AIDR 3D reconstruction and Group 2 patients (n=20, mean age 52 ± 21 years) were scanned with STD using FBP reconstruction. Objective image noise was assessed by region of interest (ROI) measurements in the liver and aorta as standard deviation (SD) of the attenuation value (Hounsfield Unit, HU) while subjective image quality was evaluated by two radiologists. Statistical analysis was used to compare the scan length, CT dose index volume (CTDIvol) and image quality of both patient groups. Although both groups have similar mean scan length, the CTDIvol significantly decreased by 38% in LD CT compared to STD CT (p<0.05). Objective and subjective image quality were statistically improved with AIDR 3D (p<0.05). In conclusion, AIDR 3D enables significant dose reduction of 38% with superior image quality in LD CT abdomen-pelvis.

  20. Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D).

    PubMed

    Chen, Marcus Y; Steigner, Michael L; Leung, Steve W; Kumamaru, Kanako K; Schultz, Kurt; Mather, Richard T; Arai, Andrew E; Rybicki, Frank J

    2013-06-01

    To compare the image quality of coronary CT angiography (CTA) studies between standard filtered back projection (FBP) and adaptive iterative dose reduction in three-dimensions (AIDR3D) reconstruction using CT noise additional software to simulate reduced radiation exposure. Images from 93 consecutive clinical coronary CTA studies were processed utilizing standard FBP, FBP with 50% simulated dose reduction (FBP50%), and AIDR3D with simulated 50% dose reduction (AIDR50%). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured within 5 regions-of-interest, and image quality for each reconstruction strategy was assessed by two independent readers using a 4-point scale. Compared to FBP, the SNR measured from the AIDR50% images was similar or higher (airway: 38.3 ± 12.7 vs. 38.5 ± 14.5, p = 0.81, fat: 5.5 ± 1.9 vs. 5.4 ± 2.0, p = 0.20, muscle: 3.2 ± 1.2 vs. 3.1 ± 1.3, p = 0.38, aorta: 22.6 ± 9.4 vs. 20.2 ± 9.7, p < 0.0001, liver: 2.7 ± 1.0 vs. 2.3 ± 1.1, p < 0.0001), while the SNR of the FBP50 % images were all lower (p values < 0.0001). The CNR measured from AIDR50% images was also higher than that from the FBP images for the aorta relative to muscle (20.5 ± 9.0 vs. 18.3 ± 9.2, p < 0.0001). The interobserver agreement in the image quality score was excellent (κ = 0.82). The quality score was significantly higher for the AIDR50% images compared to the FBP images (3.6 ± 0.6 vs. 3.3 ± 0.7, p = 0.004). Simulated radiation dose reduction applied to clinical coronary CTA images suggests that a 50% reduction in radiation dose can be achieved with adaptive iterative dose reduction software with image quality that is at least comparable to images acquired at standard radiation exposure and reconstructed with filtered back projection.

  1. Strategies and Scientific Basis of Dose Reduction on State-of-the-Art Multirow Detector X-Ray CT Systems.

    PubMed

    Karamat, Muhammad Irfan

    2015-01-01

    The continued development in multirow detector computed tomography (MDCT) technology accompanied by tremendous enhancement in the clinical utility and rapid increase in the number of MDCT scanners worldwide are causing a steep rise in the number of diagnostic computed tomography (CT) procedures performed each year. The everincreasing use of this X-radiation-based imaging technique has raised radiation protection concerns among the clinical community and general public. To address these concerns, significant efforts have been made by the clinical community as well as industry, research, and government organizations. Because of these efforts, modern MDCT systems are now equipped with a variety of tools that can lead to "radiation dose-optimized" CT images if used properly. This review describes CT dose metrics and their limitations, radiation dose reduction techniques and strategies implemented using modern MDCT scanners, and the role of research and regulatory organizations in developing guidelines and regulations to facilitate the adoption of the dose reduction strategies. An account of further developments required to achieve submillisievert X-ray CT doses and to make X-ray CT a radiation risk-free imaging modality is also given. A detailed description of the scientific basis and controversies surrounding the linear no threshold (LNT) model, which forms the basis of all radiation dose reduction strategies, is also provided in this review. According to the LNT model, there is no amount of radiation that is safe or beneficial for human beings. Based on recent epidemiological studies, despite all of the controversies, the LNT model continues to be the basis of the ALARA (as low as reasonably achievable) principle of radiation protection framework in CT.

  2. Dose reduction assessment in dynamic CT myocardial perfusion imaging in a porcine balloon-induced-ischemia model

    NASA Astrophysics Data System (ADS)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    We investigated the use of an advanced hybrid iterative reconstruction (IR) technique (iDose4, Philips Health- care) for low dose dynamic myocardial CT perfusion (CTP) imaging. A porcine model was created to mimic coronary stenosis through partial occlusion of the left anterior descending (LAD) artery with a balloon catheter. The severity of LAD occlusion was adjusted with FFR measurements. Dynamic CT images were acquired at end-systole (45% R-R) using a multi-detector CT (MDCT) scanner. Various corrections were applied to the acquired scans to reduce motion and imaging artifacts. Absolute myocardial blood flow (MBF) was computed with a deconvolution-based approach using singular value decomposition (SVD). We compared a high and a low dose radiation protocol corresponding to two different tube-voltage/tube-current combinations (80kV p/100mAs and 120kV p/150mAs). The corresponding radiation doses for these protocols are 7.8mSv and 34.3mSV , respectively. The images were reconstructed using conventional FBP and three noise-reduction strengths of the IR method, iDose. Flow contrast-to-noise ratio, CNRf, as obtained from MBF maps, was used to quantitatively evaluate the effect of reconstruction on contrast between normal and ischemic myocardial tissue. Preliminary results showed that the use of iDose to reconstruct low dose images provide better or comparable CNRf to that of high dose images reconstructed with FBP, suggesting significant dose savings. CNRf was improved with the three used levels of iDose compared to FBP for both protocols. When using the entire 4D dynamic sequence for MBF computation, a 77% dose reduction was achieved, while considering only half the scans (i.e., every other heart cycle) allowed even further dose reduction while maintaining relatively higher CNRf.

  3. Reduction in radiation doses from paediatric CT scans in Great Britain.

    PubMed

    Lee, Choonsik; Pearce, Mark S; Salotti, Jane A; Harbron, Richard W; Little, Mark P; McHugh, Kieran; Chapple, Claire-Louise; Berrington de Gonzalez, Amy

    2016-01-01

    Although CT scans provide great medical benefits, concerns have been raised about the magnitude of possible associated cancer risk, particularly in children who are more sensitive to radiation than adults. Unnecessary high doses during CT examinations can also be delivered to children, if the scan parameters are not adjusted for patient age and size. We conducted the first survey to directly assess the trends in CT scan parameters and doses for paediatric CT scans performed in Great Britain between 1978 and 2008. We retrieved 1073 CT film sets from 36 hospitals. The patients were 0-19 years old, and CT scans were conducted between 1978 and 2008. We extracted scan parameters from each film including tube current-time product [milliampere seconds (mAs)], tube potential [peak kilovoltage (kVp)] and manufacturer and model of the CT scanner. We estimated the mean mAs for head and trunk (chest and abdomen/pelvis) scans, according to patient age (0-4, 5-9, 10-14 and 15-19 years) and scan year (<1990, 1990-1994, 1995-1999 and ≥2000), and then derived the volumetric CT dose index and estimated organ doses. For head CT scans, mean mAs decreased by about 47% on average from before 1990 to after 2000, with the decrease starting around 1990. The mean mAs for head CTs did not vary with age before 1990, whereas slightly lower mAs values were used for younger patients after 1990. Similar declines in mAs were observed for trunk CTs: a 46% decline on an average from before 1990 to after 2000. Although mean mAs for trunk CTs did not vary with age before 1990, the value varied markedly by age, from 63 mAs for age 0-4 years compared with 315 mAs for those aged >15 years after 2000. No material changes in kVp were found. Estimated brain-absorbed dose from head CT scans decreased from 62 mGy before 1990 to approximately 30 mGy after 2000. For chest CT scans, the lung dose to children aged 0-4 years decreased from 28 mGy before 1990 to 4 mGy after 2000. We found that mAs for

  4. SU-E-I-37: Eye Lens Dose Reduction From CT Scan Using Organ Based Tube Current Modulation

    SciTech Connect

    Liu, H; Liu, T; Xu, X; Wu, J; Zhuo, W

    2015-06-15

    Purpose: To investigate the eye lens dose reduction by CT scan with organ based tube current modulation (OBTCM) using GPU Monte Carlo code ARCHER-CT. Methods: 36 X-ray sources and bowtie filters were placed around the patient head with the projection angle interval of 10° for one rotation of CT scan, each projection was simulated respectively. The voxel eye models with high resolution(0.1mm*0.1mm*0.1mm) were used in the simulation and different tube voltage including 80kVp, 100kVp, 120kVp and 140kVp were taken into consideration. Results: The radiation doses to the eye lens increased with the tube voltage raised from 80kVp to 140kVp, and the dose results from 0° (AP) direction are much higher than those from 180° (PA) direction for all the 4 different tube voltage investigated. This 360° projection dose characteristic enables organ based TCM, which can reduce the eye lens dose by more than 55%. Conclusion: As the eye lens belongs to superficial tissues, its radiation dose to external exposure like CT is direction sensitive, and this characteristic feature makes organ based TCM to be an effective way to reduce the eye lens dose, so more clinical use of this technique were recommended. National Nature Science Foundation of China(No.11475047)

  5. Dose reduction of cone beam CT scanning for the entire oral and maxillofacial regions with thyroid collars

    PubMed Central

    Qu, XM; Li, G; Sanderink, GCH; Zhang, ZY; Ma, XC

    2012-01-01

    Objective The aim of this study was to evaluate the influence of thyroid collars on radiation dose during cone beam CT (CBCT) scanning. Methods Average tissue-absorbed dose for a NewTom 9000 CBCT scanner (Quantitative Radiology, Verona, Italy) was measured using thermoluminescent dosemeter chips in a phantom. The scans were carried out with and without thyroid collars. Effective organ dose and total effective dose were derived using International Commission on Radiological Protection 2007 recommendations. Results The effective organ doses for the thyroid gland and oesophagus were 31.0 µSv and 2.4 µSv, respectively, during CBCT scanning without a collar around the neck. When the thyroid collars were used loosely around the neck, no effective organ dose reduction was observed. When one thyroid collar was used tightly on the front of the neck, the effective organ dose for the thyroid gland and oesophagus were reduced to 15.9 µSv (48.7% reduction) and 1.4 µSv (41.7% reduction), respectively. Similar organ dose reduction (46.5% and 41.7%) was achieved when CBCT scanning was performed with two collars tightly on the front and back of the neck. However, the differences to the total effective dose were not significant among the scans with and without collars around the neck (p = 0.775). Conclusions Thyroid collars can effectively reduce the radiation dose to the thyroid and oesophagus if used appropriately. PMID:22707330

  6. Investigation into the effects of lead shielding for fetal dose reduction in CT pulmonary angiography.

    PubMed

    Kennedy, E V; Iball, G R; Brettle, D S

    2007-08-01

    This work aims to determine whether lead shielding can be used to decrease the radiation dose to the fetus during CT scans for the diagnosis of pulmonary embolism during early stage pregnancy. An anthropomorphic phantom was modified to contain a 15 cc ionization chamber at the site of the uterus to enable fetal dose to be measured. The effects of a range of scan parameters, positioning of lead and thicknesses of lead were investigated. Fetal dose was lower with lower values of kV(p) and mAs. An increasing thickness of lead decreased the radiation dose to the uterus, as did increasing the proportion of the patient covered by the lead shielding. Fetal dose increased exponentially as the edge of the scan volume moved closer to the point of measurement. In no experiment was the dose to the fetus increased by the presence of the lead. It was found that the fetal radiation dose from a CT scan following a pulmonary embolism protocol can be effectively reduced by the use of lead shielding.

  7. Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method

    PubMed Central

    Yu, Lifeng; Fletcher, Joel G.; Shiung, Maria; Thomas, Kristen B.; Matsumoto, Jane M.; Zingula, Shannon N.; McCollough, Cynthia H.

    2016-01-01

    OBJECTIVE The objective of this study was to evaluate the radiation dose reduction potential of a novel image-based denoising technique in pediatric abdominopelvic and chest CT examinations and compare it with a commercial iterative reconstruction method. MATERIALS AND METHODS Data were retrospectively collected from 50 (25 abdominopelvic and 25 chest) clinically indicated pediatric CT examinations. For each examination, a validated noise-insertion tool was used to simulate half-dose data, which were reconstructed using filtered back-projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) methods. A newly developed denoising technique, adaptive nonlocal means (aNLM), was also applied. For each of the 50 patients, three pediatric radiologists evaluated four datasets: full dose plus FBP, half dose plus FBP, half dose plus SAFIRE, and half dose plus aNLM. For each examination, the order of preference for the four datasets was ranked. The organ-specific diagnosis and diagnostic confidence for five primary organs were recorded. RESULTS The mean (± SD) volume CT dose index for the full-dose scan was 5.3 ± 2.1 mGy for abdominopelvic examinations and 2.4 ± 1.1 mGy for chest examinations. For abdominopelvic examinations, there was no statistically significant difference between the half dose plus aNLM dataset and the full dose plus FBP dataset (3.6 ± 1.0 vs 3.6 ± 0.9, respectively; p = 0.52), and aNLM performed better than SAFIRE. For chest examinations, there was no statistically significant difference between the half dose plus SAFIRE and the full dose plus FBP (4.1 ± 0.6 vs 4.2 ± 0.6, respectively; p = 0.67), and SAFIRE performed better than aNLM. For all organs, there was more than 85% agreement in organ-specific diagnosis among the three half-dose configurations and the full dose plus FBP configuration. CONCLUSION Although a novel image-based denoising technique performed better than a commercial iterative reconstruction method in pediatric

  8. Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method.

    PubMed

    Yu, Lifeng; Fletcher, Joel G; Shiung, Maria; Thomas, Kristen B; Matsumoto, Jane M; Zingula, Shannon N; McCollough, Cynthia H

    2015-11-01

    The objective of this study was to evaluate the radiation dose reduction potential of a novel image-based denoising technique in pediatric abdominopelvic and chest CT examinations and compare it with a commercial iterative reconstruction method. Data were retrospectively collected from 50 (25 abdominopelvic and 25 chest) clinically indicated pediatric CT examinations. For each examination, a validated noise-insertion tool was used to simulate half-dose data, which were reconstructed using filtered back-projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) methods. A newly developed denoising technique, adaptive nonlocal means (aNLM), was also applied. For each of the 50 patients, three pediatric radiologists evaluated four datasets: full dose plus FBP, half dose plus FBP, half dose plus SAFIRE, and half dose plus aNLM. For each examination, the order of preference for the four datasets was ranked. The organ-specific diagnosis and diagnostic confidence for five primary organs were recorded. The mean (± SD) volume CT dose index for the full-dose scan was 5.3 ± 2.1 mGy for abdominopelvic examinations and 2.4 ± 1.1 mGy for chest examinations. For abdominopelvic examinations, there was no statistically significant difference between the half dose plus aNLM dataset and the full dose plus FBP dataset (3.6 ± 1.0 vs 3.6 ± 0.9, respectively; p = 0.52), and aNLM performed better than SAFIRE. For chest examinations, there was no statistically significant difference between the half dose plus SAFIRE and the full dose plus FBP (4.1 ± 0.6 vs 4.2 ± 0.6, respectively; p = 0.67), and SAFIRE performed better than aNLM. For all organs, there was more than 85% agreement in organ-specific diagnosis among the three half-dose configurations and the full dose plus FBP configuration. Although a novel image-based denoising technique performed better than a commercial iterative reconstruction method in pediatric abdominopelvic CT examinations, it performed worse in

  9. Assessment of patient dose reduction by bismuth shielding in CT using measurements, GEANT4 and MCNPX simulations.

    PubMed

    Mendes, M; Costa, F; Figueira, C; Madeira, P; Teles, P; Vaz, P

    2015-07-01

    This work reports on the use of two different Monte Carlo codes (GEANT4 and MCNPX) for assessing the dose reduction using bismuth shields in computer tomography (CT) procedures in order to protect radiosensitive organs such as eye lens, thyroid and breast. Measurements were performed using head and body PMMA phantoms and an ionisation chamber placed in five different positions of the phantom. Simulations were performed to estimate Computed Tomography Dose Index values using GEANT4 and MCNPX. The relative differences between measurements and simulations were <10 %. The dose reduction arising from the use of bismuth shielding ranges from 2 to 45 %, depending on the position of the bismuth shield. The percentage of dose reduction was more significant for the area covered by the bismuth shielding (36 % for eye lens, 39 % for thyroid and 45 % for breast shields).

  10. Radiation dose reduction with application of non-linear adaptive filters for abdominal CT

    PubMed Central

    Singh, Sarabjeet; Kalra, Mannudeep K; Sung, Mi Kim; Back, Anni; Blake, Michael A

    2012-01-01

    AIM: To evaluate the effect of non-linear adaptive filters (NLAF) on abdominal computed tomography (CT) images acquired at different radiation dose levels. METHODS: Nineteen patients (mean age 61.6 ± 7.9 years, M:F = 8:11) gave informed consent for an Institutional Review Board approved prospective study involving acquisition of 4 additional image series (200, 150, 100, 50 mAs and 120 kVp) on a 64 slice multidetector row CT scanner over an identical 10 cm length in the abdomen. The CT images acquired at 150, 100 and 50 mAs were processed with the NLAF. Two radiologists reviewed unprocessed and processed images for image quality in a blinded randomized manner. CT dose index volume, dose length product, patient weight, transverse diameters, objective noise and CT numbers were recorded. Data were analyzed using Analysis of Variance and Wilcoxon signed rank test. RESULTS: Of the 31 lesions detected in abdominal CT images, 28 lesions were less than 1 cm in size. Subjective image noise was graded as unacceptable in unprocessed images at 50 and 100 mAs, and in NLAF processed images at 50 mAs only. In NLAF processed images, objective image noise was decreased by 21% (14.4 ± 4/18.2 ± 4.9) at 150 mAs, 28.3% (15.7 ± 5.6/21.9 ± 4) at 100 mAs and by 39.4% (18.8 ± 9/30.4 ± 9.2) at 50 mAs compared to unprocessed images acquired at respective radiation dose levels. At 100 mAs the visibility of smaller structures improved from suboptimal in unprocessed images to excellent in NLAF processed images, whereas diagnostic confidence was respectively improved from probably confident to fully confident. CONCLUSION: NLAF lowers image noise, improves the visibility of small structures and maintains lesion conspicuity at down to 100 mAs for abdominal CT. PMID:22328968

  11. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study.

    PubMed

    Sabarudin, Akmal; Mustafa, Zakira; Nassir, Khadijah Mohd; Hamid, Hamzaini Abdul; Sun, Zhonghua

    2015-01-01

    This phantom study was designed to compare the radiation dose in thoracic and abdomen-pelvic CT scans with and without use of tube current modulation (TCM). Effective dose (ED) and size-specific dose estimation (SSDE) were calculated with the absorbed doses measured at selective radiosensitive organs using a thermoluminescence dosimeter-100 (TLD-100). When compared to protocols without TCM, the ED and SSDE were reduced significantly with use of TCM for both the thoracic and abdomen-pelvic CT. With use of TCM, the ED was 6.50±0.29 mSv for thoracic and 6.01±0.20 mSv for the abdomen-pelvic CT protocols. However without use of TCM, the ED was 20.07±0.24 mSv and 17.30±0.41 mSv for the thoracic and abdomen-pelvic CT protocols, respectively. The corresponding SSDE was 10.18±0.48 mGy and 11.96±0.27 mGy for the thoracic and abdomen-pelvic CT protocols with TCM, and 31.56±0.43 mGy and 33.23±0.05 mGy for thoracic and abdomen-pelvic CT protocols without TCM, respectively. The highest absorbed dose was measured at the breast with 8.58±0.12 mGy in the TCM protocols and 51.52±14.72 mGy in the protocols without TCM during thoracic CT. In the abdomen-pelvic CT, the absorbed dose was highest at the skin with 9.30±1.28 mGy and 29.99±2.23 mGy in protocols with and without use of TCM, respectively. In conclusion, the TCM technique results in significant dose reduction; thus it is to be highly recommended in routine thoracic and abdomen-pelvic CT. PACS numbers: 87.57.Q-, 87.57.qp, 87.53.Bn.

  12. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study.

    PubMed

    Sabarudin, Akmal; Mustafa, Zakira; Nassir, Khadijah Mohd; Hamid, Hamzaini Abdul; Sun, Zhonghua

    2014-01-08

    This phantom study was designed to compare the radiation dose in thoracic and abdomen-pelvic CT scans with and without use of tube current modulation (TCM). Effective dose (ED) and size-specific dose estimation (SSDE) were calculated with the absorbed doses measured at selective radiosensitive organs using a thermoluminescence dosimeter-100 (TLD-100). When compared to protocols without TCM, the ED and SSDE were reduced significantly with use of TCM for both the thoracic and abdomen-pelvic CT. With use of TCM, the ED was 6.50 ± 0.29 mSv for thoracic and 6.01 ± 0.20 mSv for the abdomen-pelvic CT protocols. However without use of TCM, the ED was 20.07 ± 0.24 mSv and 17.30 ± 0.41 mSv for the thoracic and abdomen-pelvic CT protocols, respectively. The corresponding SSDE was 10.18 ± 0.48 mGy and 11.96 ± 0.27 mGy for the thoracic and abdomen-pelvic CT protocols with TCM, and 31.56 ± 0.43 mGy and 33.23 ± 0.05 mGy for thoracic and abdomen-pelvic CT protocols without TCM, respectively. The highest absorbed dose was measured at the breast with 8.58 ± 0.12 mGy in the TCM protocols and 51.52 ± 14.72 mGy in the protocols without TCM during thoracic CT. In the abdomen-pelvic CT, the absorbed dose was highest at the skin with 9.30 ± 1.28mGy and 29.99 ± 2.23 mGy in protocols with and without use of TCM, respectively. In conclusion, the TCM technique results in significant dose reduction; thus it is to be highly recommended in routine thoracic and abdomen-pelvic CT.

  13. Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans.

    PubMed

    Dauer, Lawrence T; Casciotta, Kevin A; Erdi, Yusuf E; Rothenberg, Lawrence N

    2007-03-16

    It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0-15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm3 ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans.

  14. Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans

    PubMed Central

    Dauer, Lawrence T; Casciotta, Kevin A; Erdi, Yusuf E; Rothenberg, Lawrence N

    2007-01-01

    Background It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. Methods The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm3 ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. Results The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. Conclusion Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans. PMID:17367529

  15. Dose reduction in CT using bismuth shielding: measurements and Monte Carlo simulations

    PubMed Central

    Chang, Kyung-Hwan; Lee, Wonho; Choo, Dong-Myung; Lee, Choon-Sik; Kim, Youhyun

    2010-01-01

    In this research, using direct measurements and Monte Carlo calculations, the potential dose reduction achieved by bismuth shielding in computed tomography was evaluated. The patient dose was measured using an ionisation chamber in a polymethylmethacrylate (PMMA) phantom that had five measurement points at the centre and periphery. Simulations were performed using the MCNPX code. For both the bare and the bismuth-shielded phantom, the differences of dose values between experiment and simulation were within 9 %. The dose reductions due to the bismuth shielding were 1.2–55 % depending on the measurement points, X-ray tube voltage and the type of shielding. The amount of dose reduction was significant for the positions covered by the bismuth shielding (34 − 46 % for head and 41 − 55 % for body phantom on average) and negligible for other peripheral positions. The artefact on the reconstructed images were minimal when the distance between the shielding and the organs was >1 cm, and hence the shielding should be selectively located to protect critical organs such as the eye lens, thyroid and breast. The simulation results using the PMMA phantom was compared with those using a realistically voxelised phantom (KTMAN-2). For eye and breast, the simulation results using the PMMA and KTMAN-2 phantoms were similar with each other, while for thyroid the simulation results were different due to the discrepancy of locations and the sizes of the phantoms. The dose reductions achieved by bismuth and lead shielding were compared with each other and the results showed that the difference of the dose reductions achieved by the two materials was less than 2–3 %. PMID:19959602

  16. Dose reduction in CT using bismuth shielding: measurements and Monte Carlo simulations.

    PubMed

    Chang, Kyung-Hwan; Lee, Wonho; Choo, Dong-Myung; Lee, Choon-Sik; Kim, Youhyun

    2010-03-01

    In this research, using direct measurements and Monte Carlo calculations, the potential dose reduction achieved by bismuth shielding in computed tomography was evaluated. The patient dose was measured using an ionisation chamber in a polymethylmethacrylate (PMMA) phantom that had five measurement points at the centre and periphery. Simulations were performed using the MCNPX code. For both the bare and the bismuth-shielded phantom, the differences of dose values between experiment and simulation were within 9%. The dose reductions due to the bismuth shielding were 1.2-55% depending on the measurement points, X-ray tube voltage and the type of shielding. The amount of dose reduction was significant for the positions covered by the bismuth shielding (34 - 46% for head and 41 - 55% for body phantom on average) and negligible for other peripheral positions. The artefact on the reconstructed images were minimal when the distance between the shielding and the organs was >1 cm, and hence the shielding should be selectively located to protect critical organs such as the eye lens, thyroid and breast. The simulation results using the PMMA phantom was compared with those using a realistically voxelised phantom (KTMAN-2). For eye and breast, the simulation results using the PMMA and KTMAN-2 phantoms were similar with each other, while for thyroid the simulation results were different due to the discrepancy of locations and the sizes of the phantoms. The dose reductions achieved by bismuth and lead shielding were compared with each other and the results showed that the difference of the dose reductions achieved by the two materials was less than 2-3%.

  17. Accuracy and Radiation Dose Reduction of Limited-Range CT in the Evaluation of Acute Appendicitis in Pediatric Patients.

    PubMed

    Jin, Michael; Sanchez, Thomas R; Lamba, Ramit; Fananapazir, Ghaneh; Corwin, Michael T

    2017-09-01

    The purpose of this article is to determine the accuracy and radiation dose reduction of limited-range CT prescribed from the top of L2 to the top of the pubic symphysis in children with suspected acute appendicitis. We performed a retrospective study of 210 consecutive pediatric patients from December 11, 2012, through December 11, 2014, who underwent abdominopelvic CT for suspected acute appendicitis. Two radiologists independently reviewed the theoretic limited scans from the superior L2 vertebral body to the top of the pubic symphysis, to assess for visualization of the appendix, acute appendicitis, alternative diagnoses, and incidental findings. Separately, the same parameters were assessed on the full scan by the same two reviewers. Whole-body effective doses were determined for the full- and limited-range scans and were compared using the paired t test. The appendix or entire cecum was visualized on the limited scan in all cases, and no cases of acute appendicitis were missed on the simulated limited scan compared with the full scan. Two alternative diagnoses were missed with the limited scan: one case of hydronephrosis and one of acute acalculous cholecystitis. The mean effective dose for the original scan was 5.6 mSv and that for the simulated limited scan was 3.0 mSv, resulting in a dose reduction of 46.4% (p < 0.001). A limited-range CT examination performed from the top of L2 to the top of the pubic symphysis is as accurate as a full-range abdominopelvic CT in evaluating pediatric patients with suspected appendicitis and reduces the dose by approximately 46%.

  18. Dose reduction efforts for pediatric head CT imaging in Washington State trauma centers: follow-up survey results.

    PubMed

    Graves, Janessa M; Kanal, Kalpana M; Rivara, Frederick P; Jarvik, Jeffrey G; Vavilala, Monica S

    2014-02-01

    To examine variation in pediatric trauma head CT imaging protocols in Washington State trauma centers (TCs) in 2012 and compare to a previous survey conducted in 2008-2009. A mixed-mode (online and paper) survey was sent to all adult and pediatric Washington State TCs (levels 1-5). Respondents provided information about the CT scanner used for pediatric head scans and technical information about pediatric dose reduction protocols. Mean head effective dose and organ dose for a female baby were estimated. Results were compared with previous data. Sixty-one of 76 TCs responded to the 2012 survey (response rate, 80.3%, versus 76% for 2008-2009 survey). In 2012, 91.7% reported having a dedicated pediatric protocol (87.7% in 2008-2009). Protective shielding use ranged from 80% to 100% across both survey years. In 2012, 2.5 times more TCs provided sufficient information to conduct dose calculations than in 2008-2009. Estimated mean CT dose index was 23.1 milliGray (mGy) in 2012, compared with 34.8 mGy in 2008-2009 (P = .01). Estimated mean dose length product was also significantly lower in 2012 than 2008-2009 (307.6 mGy × cm versus 430.1 mGy × cm, respectively; P = .04). Wide variation in mean effective dose was observed for level 3 and 4 TCs in 2012, similar to variation observed in 2008-2009 among level 4 TCs. Mean organ dose was significantly lower in 2012 for eye lens and brain, but higher for thyroid than in 2008-2009 (P < .05). Although most Washington State TCs employ dose reduction protocols for pediatric head CTs, and some measures were lower in 2012, variation in protocols use and estimated dose continues to exist. More complete responses in 2012 suggest improved understanding of the importance of pediatric dose reduction efforts. Education and institutional protocols are necessary to reduce pediatric radiation dose from head CTs. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. Corneal Dose Reduction Using a Bismuth-Coated Latex Shield over the Eyes During Brain SPECT/CT.

    PubMed

    Matsutomo, Norikazu; Fukunaga, Masaaki; Onishi, Hideo; Yamamoto, Tomoaki

    2017-09-01

    This study aimed to determine whether a bismuth-coated latex shield (B-shield) could protect the eyes during brain SPECT/CT. Methods: A shield containing the heavy metal bismuth (equivalent to a 0.15-mm-thick lead shield) was placed over a cylindric phantom and the eyes of a 3-dimensional brain phantom filled with (99m)Tc solution. Subsequently, phantoms with and without the B-shield were compared using SPECT/CT. The CT parameters were 30-200 mA and 130 kV. The dose reduction achieved by the B-shield was measured using a pencil-shaped ionization chamber. The protective effects of the B-shield were determined by evaluating relative radioactivity concentration as well as artifacts (changes in CT number), linear attenuation coefficients, and coefficients of variation on SPECT images. Results: The radiation doses with and without the B-shield were 0.14-0.77 and 0.36-1.93 mGy, respectively, and the B-shield decreased the average radiation dose by about 60%. The B-shield also increased the mean CT number, but only at locations just beneath the surface of the phantom. Streaks of higher density near the underside of the B-shield indicated beam hardening. Linear attenuation coefficients and the coefficients of variation did not significantly differ between phantoms with and without the B-shield, and the relative (99m)Tc radioactivity concentrations were not affected. Conclusion: The B-shield decreased the radiation dose without affecting estimated attenuation correction or radioactivity concentrations. Although surface artifacts increased with the B-shield, the quality of the SPECT images was acceptable. B-shields can help protect pediatric patients and patients with eye diseases who undergo SPECT imaging. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  20. Full dose reduction potential of statistical iterative reconstruction for head CT protocols in a predominantly pediatric population

    PubMed Central

    Mirro, Amy E.; Brady, Samuel L.; Kaufman, Robert. A.

    2016-01-01

    Purpose To implement the maximum level of statistical iterative reconstruction that can be used to establish dose-reduced head CT protocols in a primarily pediatric population. Methods Select head examinations (brain, orbits, sinus, maxilla and temporal bones) were investigated. Dose-reduced head protocols using an adaptive statistical iterative reconstruction (ASiR) were compared for image quality with the original filtered back projection (FBP) reconstructed protocols in phantom using the following metrics: image noise frequency (change in perceived appearance of noise texture), image noise magnitude, contrast-to-noise ratio (CNR), and spatial resolution. Dose reduction estimates were based on computed tomography dose index (CTDIvol) values. Patient CTDIvol and image noise magnitude were assessed in 737 pre and post dose reduced examinations. Results Image noise texture was acceptable up to 60% ASiR for Soft reconstruction kernel (at both 100 and 120 kVp), and up to 40% ASiR for Standard reconstruction kernel. Implementation of 40% and 60% ASiR led to an average reduction in CTDIvol of 43% for brain, 41% for orbits, 30% maxilla, 43% for sinus, and 42% for temporal bone protocols for patients between 1 month and 26 years, while maintaining an average noise magnitude difference of 0.1% (range: −3% to 5%), improving CNR of low contrast soft tissue targets, and improving spatial resolution of high contrast bony anatomy, as compared to FBP. Conclusion The methodology in this study demonstrates a methodology for maximizing patient dose reduction and maintaining image quality using statistical iterative reconstruction for a primarily pediatric population undergoing head CT examination. PMID:27056425

  1. Pediatric CT: Strategies to Lower Radiation Dose

    PubMed Central

    Zacharias, Claudia; Alessio, Adam M.; Otto, Randolph K.; Iyer, Ramesh S.; Philips, Grace S.; Swanson, Jonathan O.; Thapa, Mahesh M.

    2016-01-01

    OBJECTIVE The introduction of MDCT has increased the utilization of CT in pediatric radiology along with concerns for radiation sequelae. This article reviews general principles of lowering radiation dose, the basic physics that impact radiation dose, and specific CT integrated dose-reduction tools focused on the pediatric population. CONCLUSION The goal of this article is to provide a comprehensive review of the recent literature regarding CT dose reduction methods, their limitations, and an outlook on future developments with a focus on the pediatric population. The discussion will initially focus on general considerations that lead to radiation dose reduction, followed by specific technical features that influence the radiation dose. PMID:23617474

  2. Is weight-based adjustment of automatic exposure control necessary for the reduction of chest CT radiation dose?

    PubMed

    Prakash, Priyanka; Kalra, Mannudeep K; Gilman, Matthew D; Shepard, Jo-Anne O; Digumarthy, Subba R

    2010-01-01

    To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; < 60 kg (n = 17), 60-90 kg (n = 52), and > 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p < 0.0001). With weight-adjusted AEC, the CTDIvol decreased to 15.8, 15.9, and 27.3 mGy for the < 60, 60-90 and > 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 +/- 3.1) and weight-adjusted (16.1 +/- 5.6) AEC techniques (p > 0.05). The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT.

  3. Reduced z-axis technique for CT Pulmonary angiography in pregnancy--validation for practical use and dose reduction.

    PubMed

    Shahir, Kaushik; McCrea, Jonathan M; Lozano, Luis Antonio Sosa; Goodman, Lawrence R

    2015-12-01

    The aim of this study is to determine the feasibility of using reduced scan range CT pulmonary angiography technique in pregnancy for pulmonary embolism (PE) and to quantify resulting dose reduction. This was a retrospective study. Eighty-four CTPA exams performed on pregnant women during 2004-2012. The scans were modified to create reduced anatomic coverage scans extending from aortic arch to base of heart. These were separately evaluated by two radiologists for PE and non-PE abnormalities. The results were then compared by the third radiologist with original radiology report and scans. Radiation dose reduction was evaluated prospectively in 36 patients as part of a quality control project. Two patients had PE and were successfully identified on reduced z-axis scans. Thirty-two exams were normal; rest had 60 pertinent and 16 had incidental findings. There were four incidental findings which included three benign thyroid nodules and one benign small lung nodule which were missed. None of these affected clinical outcome or management. There was 71 % radiation dose reduction. No PE or any important diagnoses are missed using reduced z-axis CTPA in pregnancy. There is a substantial radiation dose reduction. Hence, this technique is highly recommended in pregnancy.

  4. Automatic exposure control in pediatric and adult multidetector CT examinations: A phantom study on dose reduction and image quality

    SciTech Connect

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John

    2008-10-15

    The aim of this study was to assess the potential of a modern x,y,z modulation-based automatic exposure control system (AEC) for dose reduction in pediatric and adult multidetector CT (MDCT) imaging and evaluate the quality of the images obtained. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-, 5-, 10-year old child, and adult were scanned with a MDCT scanner, equipped with a modern AEC system. Dose reduction (%DR) was calculated as the percentage difference of the mean modulated and the preset tube current-time product that is prescribed for standard head and body scan protocols. The effect of the tube potential and the orientation of the topogram acquisition on dose reduction were assessed. Image quality was evaluated on the basis of image noise and signal to noise ratio (SNR). The dose reduction values achieved in pediatric phantoms were remarkably lower than those achieved for the adult. The efficiency of the AEC is decreased at 80 kVp compared to higher tube potentials and for helical scans following an anterior posterior (AP-AEC) compared to a lateral (LAT-AEC) topogram acquisition. In AP-AEC scans, the dose reduction ranged between 4.7 and 34.7% for neonate, 15.4 and 30.9% for 1 year old, 3.1 and 26.7% for 5 years old, 1.2 and 58.7% for 10 years old, and 15.5 and 57.4% for adult. In LAT-AEC scans, the corresponding dose reduction ranged between 11.0 and 36.5%, 27.2 and 35.7%, 11.3 and 35.6%, 0.3 and 67.0%, and 15.0 and 61.7%, respectively. AP-AEC scans resulted in a 17.1% and 19.7% dose increase in the thorax of neonate and the pelvis of the 10-year old phantom, respectively. The variation in the measured noise among images obtained along the scanning z axis was lower in AEC activated compared to fixed milliamperes scans. However, image noise was significantly increased (P<.001) and SNR significantly decreased (P<.001) in most AEC activated compared to fixed milliamperes scans. In conclusion, AEC resulted in a (i

  5. SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

    SciTech Connect

    Weir, V; Zhang, J

    2016-06-15

    Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash in one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.

  6. Dose reduction efforts for pediatric head CT imaging in Washington State trauma centers: follow-up survey results

    PubMed Central

    Kanal, Kalpana M.; Rivara, Frederick P.; Jarvik, Jeffrey G.; Vavilala, Monica S.

    2014-01-01

    Purpose To examine variation in pediatric trauma head CT imaging protocols in Washington State trauma centers (TCs) in 2012 and compare to a previous survey conducted in 2008/09. Methods A mixed-mode (online and paper) survey was sent to all adult and pediatric Washington State TCs (levels 1–5). Respondents provided information about the CT scanner used for pediatric head scans and technical information about pediatric dose reduction protocols. Mean head effective dose and organ dose for a female baby were estimated. Results were compared to previous data. Results Sixty-one of 76 TCs responded to the 2012 survey (response rate 80.3%; response rate in 2008/09 survey was 76%). In 2012, 91.7% reported having a dedicated pediatric protocol (87.7% in 2008/09). Protective shielding use ranged from 80 to 100% across both survey years. In 2012, 2.5 times more TCs provided sufficient information to conduct dose calculations than in 2008/09. Estimated mean CTDIvol was 23.1 mGy in 2012, compared to 34.8 mGy in 2008/09 (p=0.01). Estimated mean DLP was also significantly lower in 2012 than 2009/08 (307.6 mGy*cm vs. 430.1 mGy*cm, respectively; p=0.04). Wide variation in mean effective dose was observed for level 3 and 4 TCs in 2012, similar to variation observed in 2008/09 among level 4 TCs. Mean organ dose was significantly lower in 2012 for eye lens and brain, but higher for thyroid than 2008/09 (p<0.05). Conclusions While most Washington State TCs employ dose reduction protocols for pediatric head CTs, and some measures were lower in 2012, variation in protocols use and estimated dose continues to exist. More complete responses in 2012 suggest improved understanding of the importance of pediatric dose reduction efforts. Education and institutional protocols are necessary to reduce pediatric radiation dose from head CTs. PMID:24360905

  7. Quantification of radiation dose reduction by reducing z-axis coverage in 320-detector coronary CT angiography.

    PubMed

    Murphy, David J; Keraliya, Abhishek; Himes, Nathan; Aghayev, Ayaz; Blankstein, Ron; Steigner, Michael L

    2017-08-01

    To quantify the radiation dose reduction achievable by minimizing z-axis coverage in 320-detector coronary CT angiography (CCTA). We retrospectively reviewed 130 CCTAs performed on 320-detector CT that offers up to 16 cm z-axis coverage (adjustable in 2-cm increments), allowing complete coverage of the heart in a single gantry rotation. For each CT, we obtained the radiation dose [CT dose index and dose-length product (DLP)], measured the z-axis field of view and measured the craniocaudal cardiac size (distance from the left main coronary artery to the cardiac apex). We calculated the radiation dose savings achievable by reducing the z-axis coverage to the minimum necessary to cover the heart using 320 × 0.5-mm (maximum 16 cm) and 256 × 0.5-mm (maximum 12.8 cm) detector collimations. Results are expressed as mean ± standard deviation. The mean craniocaudal cardiac size was 10.5 ± 1.0 cm, with 85% (n = 112) of CCTAs performed with 16 cm of z-axis coverage. The mean DLP was 417.6 ± 182.4 mGy cm, with the mean DLP saving achievable using the minimum z-axis coverage required to completely image the heart being 96.2 ± 47.4 mGy cm, an average dose reduction of 26.9 ± 7.0%. z-axis coverage of ≤12 cm was adequate for 92% and 12.8 cm for 98% of subjects. Using the minimal z-axis coverage to adequately image the heart is a simple step that can reduce the DLP in 320-detector CCTA by approximately 27%. z-axis coverage of ≤12 cm is adequate for 92%, 12.8 cm for 98% and 14 cm for 100% of patients undergoing CCTA. Advances in knowledge: Reducing z-axis coverage in 320-detector CCTA can reduce DLP by approximately 27%.

  8. Systematic Evaluation of Radiation Dose Reduction in CT Studies of Body Packers: Accuracy Down to Submillisievert Levels.

    PubMed

    Laberke, Patrick J; Blum, Simon; Waelti, Stephan; Fornaro, Jürgen; Hausmann, Roland; Alkadhi, Hatem; Leschka, Sebastian

    2016-04-01

    The objective of this study was to systematically evaluate the accuracy of abdominal CT performed at different radiation dose levels for the detection of body packs in human cadavers, in comparison with the accuracy of abdominal radiography. In this study, differing numbers of body packs (range, 0-20) were placed in the alimentary tract of human cadavers and then underwent imaging with abdominal radiography and with CT performed at different radiation dose levels (ranging from the standard abdominal CT dose to the technical minimum dose). Depiction of body packs on abdominal radiographs and on each CT scan was assessed by two independent blinded radiologists, and the accuracy of detection of body packs was calculated. The radiation dose associated with abdominal radiography was measured, and the effective radiation dose associated with CT was estimated. The mean (± SD) effective radiation dose for abdominal radiography was 1.4 ± 0.3 mSv, whereas the mean effective dose of CT ranged from 0.1 to 9.6 mSv. Interobserver agreement for body pack detection was moderate (κ = 0.51) for abdominal radiography and good (κ = 0.72-0.85) for CT. In a per-body pack analysis, abdominal radiography depicted 42% of the body packs with a sensitivity of 71% and a specificity of 100%. When performed at radiation dose levels of 0.6 mSv or greater, CT correctly detected all body packs. In per-person analysis, the sensitivity and specificity of CT for the correct detection of at least one body pack per cadaver was 100% for all radiation dose levels. CT performed at a dose of 0.6 mSv can be used for the detection of body packs. With a sensitivity and specificity of 100%, CT is superior to abdominal radiography in terms of reliability, associated radiation dose, and accuracy of detection.

  9. Whole-body PET/CT studies with lowered ¹⁸F-FDG doses: the influence of body mass index in dose reduction.

    PubMed

    Sánchez-Jurado, Raúl; Devis, Manuel; Sanz, Rut; Aguilar, Jose Enrique; del Puig Cózar, Maria; Ferrer-Rebolleda, Jose

    2014-03-01

    The administered dose of (18)F-FDG can be greatly reduced using body mass index (BMI) instead of the patient's weight, without diminishing image quality. We have focused on reducing the administered dose while maintaining the acquisition time and have developed dosing-based algorithms using BMI. We conducted a prospective dose-adjustment research study with more than 1,800 patients undergoing time-of-flight PET/CT. From January 2009 to October 2010 we recruited 1,000 patients, of whom 180 were randomly selected to create the control group. The treatment group was created by selecting 180 new subjects from a total of 800 recruited from January to December 2011. The control group was administered a body weight-calculated dose of 5.55-7.4 MBq/kg. The treatment group was administered a BMI-calculated dose of 6.85-11.1 MBq/BMI. Each group was divided into 5 subgroups according to BMI classification (underweight, normal weight, overweight, obese, and morbidly obese). All scans were acquired with a time-of-flight PET/CT scanner and were evaluated in a masked manner by 2 nuclear medicine physicians. Evaluation of images was purely qualitative, with visual scoring of image quality from 1 to 3 (high to low). These data were analyzed for statistical significance. Dosimetric measures of patients' emitted radiation were taken at the surface and at a distance of 0.5 m and 1 m to compare the groups. The readings of PET staff dosimeters were evaluated during this period and analyzed. A reduction of between 9% and 22% in administered dose per patient was achieved for the BMI-derived dose group with respect to the body weight-calculated dose group. In addition, an effective dose reduction of 56% and 12.5% for patients and staff, respectively, was achieved. The cost per study was therefore reduced while diagnostic image quality was maintained or even improved in most cases. BMI-calculated doses, which are often lower than strictly weight-based doses, can be administered while

  10. Reduction of eye lens radiation dose by orbital bismuth shielding in pediatric patients undergoing CT of the head: A Monte Carlo study

    SciTech Connect

    Perisinakis, Kostas; Raissaki, Maria; Tzedakis, Antonis; Theocharopoulos, Nicholas; Damilakis, John; Gourtsoyiannis, Nicholas

    2005-04-01

    Our aim in the study was to assess the eye lens dose reduction resulting from the use of radioprotective bismuth garments to shield the eyes of pediatric patients undergoing head CT. The Monte Carlo N-particle transport code and mathematical humanoid phantoms representing the average individual at different ages were used to determine eye lens dose reduction accomplished with bismuth shielding of the eye in the following simulated CT scans: (a) scanning of the orbits, (b) scanning of the whole head, and (c) 20 deg. angled scanning of the brain excluding the orbits. The effect of bismuth shielding on the eye lens dose was also investigated using an anthropomorphic phantom and thermoluminescence dosimetry (TLD). Eye lens dose reduction achieved by bismuth shielding was measured in 16 patients undergoing multiphase CT scanning of the head. The patient's scans were divided in the following: CT examinations where the eye globes were entirely included (n=5), partly included (n=6) and excluded (n=5) from the scanned region. The eye lens dose reduction depended mainly on the scan boundaries set by an operator. The average eye lens dose reduction determined by Monte Carlo simulation was 38.2%, 33.0% and <1% for CT scans of the orbits, whole head, and brain with an angled gantry, respectively. The difference between the Monte Carlo derived eye lens dose reduction factor values and corresponding values determined directly by using the anthropomorphic phantom head was found less than 5%. The mean eye lens dose reduction achieved by bismuth shielding in pediatric patients were 34%, 20% and <2% when eye globes were entirely included, partly included and excluded from the scanned region, respectively. A significant reduction in eye lens dose may be achieved by using superficial orbital bismuth shielding during pediatric head CT scans. However, bismuth garments should not be used in children when the eyes are excluded from the primarily exposed region.

  11. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations.

    PubMed

    Guziński, Maciej; Waszczuk, Łukasz; Sąsiadek, Marek J

    2016-10-01

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. •With ASiR it is possible to lower radiation dose or improve image quality •Sequentional imaging allows setting scan parameters for brain and posterior-fossa independently •We improved visibility of brainstem structures and decreased radiation dose •Total radiation dose (DLP) was decreased by 19.

  12. Adaptive Iterative Dose Reduction Using Three Dimensional Processing (AIDR3D) Improves Chest CT Image Quality and Reduces Radiation Exposure

    PubMed Central

    Yamashiro, Tsuneo; Miyara, Tetsuhiro; Honda, Osamu; Kamiya, Hisashi; Murata, Kiyoshi; Ohno, Yoshiharu; Tomiyama, Noriyuki; Moriya, Hiroshi; Koyama, Mitsuhiro; Noma, Satoshi; Kamiya, Ayano; Tanaka, Yuko; Murayama, Sadayuki

    2014-01-01

    Objective To assess the advantages of Adaptive Iterative Dose Reduction using Three Dimensional Processing (AIDR3D) for image quality improvement and dose reduction for chest computed tomography (CT). Methods Institutional Review Boards approved this study and informed consent was obtained. Eighty-eight subjects underwent chest CT at five institutions using identical scanners and protocols. During a single visit, each subject was scanned using different tube currents: 240, 120, and 60 mA. Scan data were converted to images using AIDR3D and a conventional reconstruction mode (without AIDR3D). Using a 5-point scale from 1 (non-diagnostic) to 5 (excellent), three blinded observers independently evaluated image quality for three lung zones, four patterns of lung disease (nodule/mass, emphysema, bronchiolitis, and diffuse lung disease), and three mediastinal measurements (small structure visibility, streak artifacts, and shoulder artifacts). Differences in these scores were assessed by Scheffe's test. Results At each tube current, scans using AIDR3D had higher scores than those without AIDR3D, which were significant for lung zones (p<0.0001) and all mediastinal measurements (p<0.01). For lung diseases, significant improvements with AIDR3D were frequently observed at 120 and 60 mA. Scans with AIDR3D at 120 mA had significantly higher scores than those without AIDR3D at 240 mA for lung zones and mediastinal streak artifacts (p<0.0001), and slightly higher or equal scores for all other measurements. Scans with AIDR3D at 60 mA were also judged superior or equivalent to those without AIDR3D at 120 mA. Conclusion For chest CT, AIDR3D provides better image quality and can reduce radiation exposure by 50%. PMID:25153797

  13. Evaluation of exposure dose reduction in multislice CT coronary angiography (MS-CTA) with prospective ECG-gated helical scan

    NASA Astrophysics Data System (ADS)

    Ota, Takamasa; Tsuyuki, Masaharu; Okumura, Miwa; Sano, Tomonari; Kondo, Takeshi; Takase, Shinichi

    2008-03-01

    A novel low-dose ECG-gated helical scan method to investigate coronary artery diseases was developed. This method uses a high pitch for scanning (based on the patient's heart rate) and X-rays are generated only during the optimal cardiac phases. The dose reduction was obtained using a two-level approach: 1) To use a 64-slice CT scanner (Aquilion, Toshiba, Otawara, Tochigi, Japan) with a scan speed of 0.35 s/rot. to helically scan the heart at a high pitch based on the patient's heart rate. By changing the pitch from the conventional 0.175 to 0.271 for a heart rate of 60 bpm, the exposure dose was reduced to 65%. 2) To employ tube current gating that predicts the timing of optimal cardiac phases from the previous cardiac cycle and generates X-rays only during the required cardiac phases. The combination of high speed scanning with a high pitch and appropriate X-ray generation only in the cardiac phases from 60% to 90% allows the exposure dose to be reduced to 5.6 mSv for patients with a heart rate lower than 65 bpm. This is a dose reduction of approximately 70% compared to the conventional scanning method recommended by the manufacturer when segmental reconstruction is considered. This low-dose protocol seamlessly allows for wide scan ranges (e.g., aortic dissection) with the benefits of ECG-gated helical scanning: smooth continuity for longitudinal direction and utilization of data from all cardiac cycles.

  14. Lead versus bismuth-antimony shield for fetal dose reduction at different gestational ages at CT pulmonary angiography.

    PubMed

    Chatterson, Leslie C; Leswick, David A; Fladeland, Derek A; Hunt, Megan M; Webster, Stephen T

    2011-08-01

    To compare the effective fetal dose reduction at different stages of gestation during maternal computed tomographic (CT) pulmonary angiography by using traditional lead apron and bismuth-antimony shields combined with limited z-axis and tube current. Phantom with gravid prosthesis, 0.5-mm lead, and two grades of bismuth-antimony shield was used. Thermoluminescent dosimeters (TLDs) measured radiation in the first- to third-trimester uterus. Fetal dose was determined for each gestation by using 100 kVp to the costophrenic angles (CPAs) with and without shielding for a total of 12 scans. Eight third-trimester scans were used to compare shields using 120 kVp to CPAs versus those using 100 kVp to the diaphragm. Average fetal dose increased with gestation with use of 100 kVp to CPAs, from 0.11 mGy in first trimester to 0.50 mGy in third trimester. Average third-trimester unshielded fetal dose was reduced from 0.82 mGy by using 120 kVp to CPAs to 0.17 mGy (79%, P < .001) by using 100 kVp to the diaphragm. Lead apron reduced dose more than either of the bismuth-antimony shields (72%-79% vs 57%-81%) with use of 100 kVp to CPAs. Shields reduced the dose by 73% (lead), 62% (90% attenuation bismuth-antimony), and 72% (95% attenuation bismuth-antimony) (P < .01) at 120 kVp to CPAs. No significant difference between shields was demonstrated with 100 kVp to the diaphragm (P < .01). Maternal dose was 8.13 mSv at 120 kVp to CPAs, 4.90 mSv at 100 kVp to CPAs, and 4.02 mSv at 100 kVp to the diaphragm. Reducing voltage and limiting z-axis is more effective than shields at reducing fetal dose. Shielding improves reduction with no significant difference between lead and bismuth-antimony shields when conservative scanning parameters are observed. © RSNA, 2011.

  15. Radiation dose reduction to the breast in thoracic CT: Comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current

    SciTech Connect

    Wang Jia; Duan Xinhui; Christner, Jodie A.; Leng Shuai; Yu Lifeng; McCollough, Cynthia H.

    2011-11-15

    Purpose: The purpose of this work was to evaluate dose performance and image quality in thoracic CT using three techniques to reduce dose to the breast: bismuth shielding, organ-based tube current modulation (TCM) and global tube current reduction. Methods: Semi-anthropomorphic thorax phantoms of four different sizes (15, 30, 35, and 40 cm lateral width) were used for dose measurement and image quality assessment. Four scans were performed on each phantom using 100 or 120 kV with a clinical CT scanner: (1) reference scan; (2) scan with bismuth breast shield of an appropriate thickness; (3) scan with organ-based TCM; and (4) scan with a global reduction in tube current chosen to match the dose reduction from bismuth shielding. Dose to the breast was measured with an ion chamber on the surface of the phantom. Image quality was evaluated by measuring the mean and standard deviation of CT numbers within the lung and heart regions. Results: Compared to the reference scan, dose to the breast region was decreased by about 21% for the 15-cm phantom with a pediatric (2-ply) shield and by about 37% for the 30, 35, and 40-cm phantoms with adult (4-ply) shields. Organ-based TCM decreased the dose by 12% for the 15-cm phantom, and 34-39% for the 30, 35, and 40-cm phantoms. Global lowering of the tube current reduced breast dose by 23% for the 15-cm phantom and 39% for the 30, 35, and 40-cm phantoms. In phantoms of all four sizes, image noise was increased in both the lung and heart regions with bismuth shielding. No significant increase in noise was observed with organ-based TCM. Decreasing tube current globally led to similar noise increases as bismuth shielding. Streak and beam hardening artifacts, and a resulting artifactual increase in CT numbers, were observed for scans with bismuth shields, but not for organ-based TCM or global tube current reduction. Conclusions: Organ-based TCM produces dose reduction to the breast similar to that achieved with bismuth shielding for

  16. Can a revised paediatric radiation dose reduction CT protocol be applied and still maintain anatomical delineation, diagnostic confidence and overall imaging quality?

    PubMed Central

    Siriwanarangsun, P; Tanaanantarak, P; Krisanachinda, A

    2014-01-01

    Objective: To compare multidetector CT (MDCT) radiation doses between default settings and a revised dose reduction protocol and to determine whether the diagnostic confidence can be maintained with imaging quality made under the revised protocol in paediatric head, chest and abdominal CT studies. Methods: The study retrospectively reviewed head, chest, abdominal and thoracoabdominal MDCT studies, comparing 231 CT studies taken before (Phase 1) and 195 CT studies taken after (Phase 2) the implemented revised protocol. Image quality was assessed using a five-point grading scale based on anatomical criteria, diagnostic confidence and overall quality. Image noise and dose–length product (DLP) were collected and compared. Results: The relative dose reductions between Phase 1 and Phase 2 were statistically significant in 35%, 51% and 54% (p < 0.001) of head, chest and abdominal CT studies, respectively. There were no statistically significant differences in overall image quality score comparisons in the head (p = 0.3), chest (p = 0.7), abdominal (p = 0.7) and contiguous thoracic (p = 0.1) and abdominal (p = 0.2) CT studies, with the exception of anatomical quality in definition of bronchial walls and delineation of intrahepatic portal branches in thoracoabdominal CTs, and diagnostic confidence in mass lesion in head CTs, liver lesion (>1 cm), splanchnic venous thrombosis, pancreatitis in abdominal CTs, and emphysema and aortic dissection in thoracoabdominal CTs. Conclusion: Paediatric CT radiation doses can be significantly reduced from manufacturer's default protocol while still maintaining anatomical delineation, diagnostic confidence and overall imaging quality. Advances in knowledge: Revised paediatric CT protocol can provide a half DLP reduction while preserving overall imaging quality. PMID:24959737

  17. The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique.

    PubMed

    Kwon, Heejin; Cho, Jinhan; Oh, Jongyeong; Kim, Dongwon; Cho, Junghyun; Kim, Sanghyun; Lee, Sangyun; Lee, Jihyun

    2015-10-01

    To investigate whether reduced radiation dose abdominal CT images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) compromise the depiction of clinically competent features when compared with the currently used routine radiation dose CT images reconstructed with ASIR. 27 consecutive patients (mean body mass index: 23.55 kg m(-2) underwent CT of the abdomen at two time points. At the first time point, abdominal CT was scanned at 21.45 noise index levels of automatic current modulation at 120 kV. Images were reconstructed with 40% ASIR, the routine protocol of Dong-A University Hospital. At the second time point, follow-up scans were performed at 30 noise index levels. Images were reconstructed with filtered back projection (FBP), 40% ASIR, 30% ASIR-V, 50% ASIR-V and 70% ASIR-V for the reduced radiation dose. Both quantitative and qualitative analyses of image quality were conducted. The CT dose index was also recorded. At the follow-up study, the mean dose reduction relative to the currently used common radiation dose was 35.37% (range: 19-49%). The overall subjective image quality and diagnostic acceptability of the 50% ASIR-V scores at the reduced radiation dose were nearly identical to those recorded when using the initial routine-dose CT with 40% ASIR. Subjective ratings of the qualitative analysis revealed that of all reduced radiation dose CT series reconstructed, 30% ASIR-V and 50% ASIR-V were associated with higher image quality with lower noise and artefacts as well as good sharpness when compared with 40% ASIR and FBP. However, the sharpness score at 70% ASIR-V was considered to be worse than that at 40% ASIR. Objective image noise for 50% ASIR-V was 34.24% and 46.34% which was lower than 40% ASIR and FBP. Abdominal CT images reconstructed with ASIR-V facilitate radiation dose reductions of to 35% when compared with the ASIR. This study represents the first clinical research experiment to use ASIR-V, the newest version of

  18. Radiation dose reduction using a neck detection algorithm for single spiral brain and cervical spine CT acquisition in the trauma setting.

    PubMed

    Ardley, Nicholas D; Lau, Ken K; Buchan, Kevin

    2013-12-01

    Cervical spine injuries occur in 4-8 % of adults with head trauma. Dual acquisition technique has been traditionally used for the CT scanning of brain and cervical spine. The purpose of this study was to determine the efficacy of radiation dose reduction by using a single acquisition technique that incorporated both anatomical regions with a dedicated neck detection algorithm. Thirty trauma patients for brain and cervical spine CT were included and were scanned with the single acquisition technique. The radiation doses from the single CT acquisition technique with the neck detection algorithm, which allowed appropriate independent dose administration relevant to brain and cervical spine regions, were recorded. Comparison was made both to the doses calculated from the simulation of the traditional dual acquisitions with matching parameters, and to the doses of retrospective dual acquisition legacy technique with the same sample size. The mean simulated dose for the traditional dual acquisition technique was 3.99 mSv, comparable to the average dose of 4.2 mSv from 30 previous patients who had CT of brain and cervical spine as dual acquisitions. The mean dose from the single acquisition technique was 3.35 mSv, resulting in a 16 % overall dose reduction. The images from the single acquisition technique were of excellent diagnostic quality. The new single acquisition CT technique incorporating the neck detection algorithm for brain and cervical spine significantly reduces the overall radiation dose by eliminating the unavoidable overlapping range between 2 anatomical regions which occurs with the traditional dual acquisition technique.

  19. Cone beam CT dose reduction in prostate radiotherapy using Likert scale methods.

    PubMed

    Langmack, Keith A; Newton, Louise A; Jordan, Suzanne; Smith, Ruth

    2016-01-01

    To use a Likert scale method to optimize image quality (IQ) for cone beam CT (CBCT) soft-tissue matching for image-guided radiotherapy of the prostate. 23 males with local/locally advanced prostate cancer had the CBCT IQ assessed using a 4-point Likert scale (4 = excellent, no artefacts; 3 = good, few artefacts; 2 = poor, just able to match; 1 = unsatisfactory, not able to match) at three levels of exposure. The lateral separations of the subjects were also measured. The Friedman test and Wilcoxon signed-rank tests were used to determine if the IQ was associated with the exposure level. We used the point-biserial correlation and a χ(2) test to investigate the relationship between the separation and IQ. The Friedman test showed that the IQ was related to exposure (p = 2 × 10(-7)) and the Wilcoxon signed-rank test demonstrated that the IQ decreased as exposure decreased (all p-values <0.005). We did not find a correlation between the IQ and the separation (correlation coefficient 0.045), but for separations <35 cm, it was possible to use the lowest exposure parameters studied. We can reduce exposure factors to 80% of those supplied with the system without hindering the matching process for all patients. For patients with lateral separations <35 cm, the exposure factors can be reduced further to 64% of the original values. Likert scales are a useful tool for measuring IQ in the optimization of CBCT IQ for soft-tissue matching in radiotherapy image guidance applications.

  20. Cone beam CT dose reduction in prostate radiotherapy using Likert scale methods

    PubMed Central

    Newton, Louise A; Jordan, Suzanne; Smith, Ruth

    2016-01-01

    Objective: To use a Likert scale method to optimize image quality (IQ) for cone beam CT (CBCT) soft-tissue matching for image-guided radiotherapy of the prostate. Methods: 23 males with local/locally advanced prostate cancer had the CBCT IQ assessed using a 4-point Likert scale (4 = excellent, no artefacts; 3 = good, few artefacts; 2 = poor, just able to match; 1 = unsatisfactory, not able to match) at three levels of exposure. The lateral separations of the subjects were also measured. The Friedman test and Wilcoxon signed-rank tests were used to determine if the IQ was associated with the exposure level. We used the point-biserial correlation and a χ2 test to investigate the relationship between the separation and IQ. Results: The Friedman test showed that the IQ was related to exposure (p = 2 × 10−7) and the Wilcoxon signed-rank test demonstrated that the IQ decreased as exposure decreased (all p-values <0.005). We did not find a correlation between the IQ and the separation (correlation coefficient 0.045), but for separations <35 cm, it was possible to use the lowest exposure parameters studied. Conclusion: We can reduce exposure factors to 80% of those supplied with the system without hindering the matching process for all patients. For patients with lateral separations <35 cm, the exposure factors can be reduced further to 64% of the original values. Advances in knowledge: Likert scales are a useful tool for measuring IQ in the optimization of CBCT IQ for soft-tissue matching in radiotherapy image guidance applications. PMID:26689092

  1. A comparison of adaptive iterative dose reduction 3D and filtered back projection in craniocervical CT angiography.

    PubMed

    Yu, S; Zhang, L; Zheng, J; Xu, Y; Chen, Y; Song, Z

    2017-01-01

    To compare the effects of exposure parameters on image quality and radiation dose for craniocervical computed tomography angiography (CTA) using adaptive iterative dose reduction in three dimensions (AIDR 3D) and filtered back projection (FBP) algorithms. One hundred and eighty patients were divided into three groups; group A (120 kV, 300 mA, FBP), group B (100 kV, automatic mA, AIDR 3D) and group C (80kV, automatic mA, AIDR 3D). Image quality and radiation dose were evaluated for each group. For both cervical and intracranial vessels, CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were higher in the AIDR 3D groups. The difference in mean vascular noise was also statistically significant (p<0.001), with group B having the lowest value at 16.5±3.2 HU and group C having the highest at 19.1±2.9 HU. FBP reconstruction resulted in lower image-quality scores for the common carotid artery. Parenchymal image-quality scores also varied significantly different between groups with group C partially failing to meet the minimum standards for diagnostic use. For the middle cerebral artery, image-quality scores were significantly better in group A, although images from groups B and C also satisfied clinical diagnostic requirements. The image quality of the internal carotid artery was the best in group B. Image-quality scores between groups were not significantly different for the carotid sinus. Radiation doses in the groups using AIDR 3D were >70% lower than in the FBP group. AIDR 3D (100 kV, automatic modulation) provides optimal image quality of vascular and parenchymal tissues at significantly lower radiation doses (mSV) than FBP in craniocervical CTA. For cases in which highly accurate parenchymal assessment is not required, the tube voltage can be lowered to 80 kV to further decrease radiation dose. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  2. NIH-funded study shows 20 percent reduction in lung cancer mortality with low-dose CT compared to chest X-ray: | Division of Cancer Prevention

    Cancer.gov

    Scientists have found a 20 percent reduction in deaths from lung cancer among current or former heavy smokers who were screened with low-dose helical computed tomography (CT) versus those screened by chest X-ray. The primary research results from the National Lung Screening Trial (NLST) were published online today in the New England Journal of Medicine. |

  3. Sci—Fri AM: Mountain — 02: A comparison of dose reduction methods on image quality for cone beam CT

    SciTech Connect

    Webb, R; Buckley, LA

    2014-08-15

    Modern radiotherapy uses highly conformai dose distributions and therefore relies on daily image guidance for accurate patient positioning. Kilovoltage cone beam CT is one technique that is routinely used for patient set-up and results in a high dose to the patient relative to planar imaging techniques. This study uses an Elekta Synergy linac equipped with XVI cone beam CT to investigate the impact of various imaging parameters on dose and image quality. Dose and image quality are assessed as functions of x-ray tube voltage, tube current and the number of projections in the scan. In each case, the dose measurements confirm that as each parameter increases the dose increases. The assessment of high contrast resolution shows little dependence on changes to the image technique. However, low contrast visibility suggests a trade off between dose and image quality. Particularly for changes in tube potential, the dose increases much faster as a function of voltage than the corresponding increase in low contrast image quality. This suggests using moderate values of the peak tube voltage (100 – 120 kVp) since higher values result in significant dose increases with little gain in image quality. Measurements also indicate that increasing tube current achieves the greatest degree of improvement in the low contrast visibility. The results of this study highlight the need to establish careful imaging protocols to limit dose to the patient and to limit changes to the imaging parameters to those cases where there is a clear clinical requirement for improved image quality.

  4. Spatial resolution improvement and dose reduction potential for inner ear CT imaging using a z-axis deconvolution technique.

    PubMed

    McCollough, Cynthia H; Leng, Shuai; Sunnegardh, Johan; Vrieze, Thomas J; Yu, Lifeng; Lane, John; Raupach, Rainer; Stierstorfer, Karl; Flohr, Thomas

    2013-06-01

    To assess the z-axis resolution improvement and dose reduction potential achieved using a z-axis deconvolution technique with iterative reconstruction (IR) relative to filtered backprojection (FBP) images created with the use of a z-axis comb filter. Each of three phantoms were scanned with two different acquisition modes: (1) an ultrahigh resolution (UHR) scan mode that uses a comb filter in the fan angle direction to increase in-plane spatial resolution and (2) a z-axis ultrahigh spatial resolution (zUHR) scan mode that uses comb filters in both the fan and cone angle directions to improve both in-plane and z-axis spatial resolution. All other scanning parameters were identical. First, the ACR CT Accreditation phantom, rotated by 90° so that the high-contrast spatial resolution targets were parallel to the coronal plane, was scanned to assess limiting spatial resolution and image noise. Second, section sensitivity profiles (SSPs) were measured using a copper foil embedded in an acrylic cylinder and the full-width-at-half-maximum (FWHM) and full-width-at-tenth-maximum (FWTM) of the SSPs were calculated. Third, an anthropomorphic head phantom containing a human skull was scanned to assess clinical acceptability for imaging of the temporal bone. For each scan, FBP images were reconstructed for the zUHR scan using the narrowest image thickness available. For the CT accreditation phantom, zUHR images were also reconstructed using an IR algorithm (SAFIRE, Siemens Healthcare, Forchheim, Germany) to assess the influence of the IR algorithm on image noise. A z-axis deconvolution technique combined with the IR algorithm was used to reconstruct images at the narrowest image thickness possible from the UHR scan data. Images of the ACR and head phantoms were reformatted into the coronal plane. The head phantom images were evaluated by a neuroradiologist to assess acceptability for use in patients undergoing clinically indicated CT imaging of the temporal bone. The limiting

  5. Radiation dose reduction in computed tomography (CT) using a new implementation of wavelet denoising in low tube current acquisitions

    NASA Astrophysics Data System (ADS)

    Tao, Yinghua; Brunner, Stephen; Tang, Jie; Speidel, Michael; Rowley, Howard; VanLysel, Michael; Chen, Guang-Hong

    2011-03-01

    Radiation dose reduction remains at the forefront of research in computed tomography. X-ray tube parameters such as tube current can be lowered to reduce dose; however, images become prohibitively noisy when the tube current is too low. Wavelet denoising is one of many noise reduction techniques. However, traditional wavelet techniques have the tendency to create an artificial noise texture, due to the nonuniform denoising across the image, which is undesirable from a diagnostic perspective. This work presents a new implementation of wavelet denoising that is able to achieve noise reduction, while still preserving spatial resolution. Further, the proposed method has the potential to improve those unnatural noise textures. The technique was tested on both phantom and animal datasets (Catphan phantom and timeresolved swine heart scan) acquired on a GE Discovery VCT scanner. A number of tube currents were used to investigate the potential for dose reduction.

  6. Strategies for reducing radiation dose in CT.

    PubMed

    McCollough, Cynthia H; Primak, Andrew N; Braun, Natalie; Kofler, James; Yu, Lifeng; Christner, Jodie

    2009-01-01

    In recent years, the media has focused on the potential danger of radiation exposure from CT, even though the potential benefit of a medically indicated CT far outweighs the potential risks. This attention has reminded the radiology community that doses must be as low as reasonably achievable (ALARA) while maintaining diagnostic image quality. To satisfy the ALARA principle, the dose reduction strategies described in this article must be well understood and properly used. The use of CT must also be justified for the specific diagnostic task.

  7. Cone beam CT with zonal filters for simultaneous dose reduction, improved target contrast and automated set-up in radiotherapy.

    PubMed

    Moore, C J; Marchant, T E; Amer, A M

    2006-05-07

    Cone beam CT (CBCT) using a zonal filter is introduced. The aims are reduced concomitant imaging dose to the patient, simultaneous control of body scatter for improved image quality in the tumour target zone and preserved set-up detail for radiotherapy. Aluminium transmission diaphragms added to the CBCT x-ray tube of the Elekta Synergytrade mark linear accelerator produced an unattenuated beam for a central "target zone" and a partially attenuated beam for an outer "set-up zone". Imaging doses and contrast noise ratios (CNR) were measured in a test phantom for transmission diaphragms 12 and 24 mm thick, for 5 and 10 cm long target zones. The effect on automatic registration of zonal CBCT to conventional CT was assessed relative to full-field and lead-collimated images of an anthropomorphic phantom. Doses along the axis of rotation were reduced by up to 50% in both target and set-up zones, and weighted dose (two thirds surface dose plus one third central dose) was reduced by 10-20% for a 10 cm long target zone. CNR increased by up to 15% in zonally filtered CBCT images compared to full-field images. Automatic image registration remained as robust as that with full-field images and was superior to CBCT coned down using lead-collimation. Zonal CBCT significantly reduces imaging dose and is expected to benefit radiotherapy through improved target contrast, required to assess target coverage, and wide-field edge detail, needed for robust automatic measurement of patient set-up error.

  8. Efficacy of a dynamic collimator for overranging dose reduction in a second- and third-generation dual source CT scanner.

    PubMed

    Booij, Ronald; Dijkshoorn, Marcel L; van Straten, Marcel

    2017-09-01

    The purpose of this study was to assess the efficacy of the renewed dynamic collimator in a third-generation dual source CT (DSCT) scanner and to determine the improvements over the second-generation scanner. Collimator efficacy is defined as the percentage overranging dose in terms of dose-length product (DLP) that is blocked by the dynamic collimator relative to the total overranging dose in case of a static collimator. Efficacy was assessed at various pitch values and different scan lengths. The number of additional rotations due to overranging and effective scan length were calculated on the basis of reported scanning parameters. On the basis of these values, the efficacy of the collimator was calculated. The second-generation scanner showed decreased performance of the dynamic collimator at increasing pitch. Efficacy dropped to 10% at the highest pitch. For the third-generation scanner the efficacy remained above 50% at higher pitch. Noise was for some pitch values slightly higher at the edge of the imaged volume, indicating a reduced scan range to reduce the overranging dose. The improved dynamic collimator in the third-generation scanner blocks the overranging dose for more than 50% and is more capable of shielding radiation dose, especially in high pitch scan modes. • Overranging dose is to a large extent blocked by the dynamic collimator • Efficacy is strongly improved within the third-generation DSCT scanner • Reducing the number of additional rotations can reduce overranging with increased noise.

  9. Feasibility of Dose Reduction Using Novel Denoising Techniques for Low kV (80 kV) CT Enterography: Optimization and Validation

    PubMed Central

    Guimarães, Luís S; Fletcher, Joel G; Yu, Lifeng; Huprich, James E; Fidler, Jeff L.; Manduca, Armando; Ramirez-Giraldo, Juan Carlos; Holmes, David R.; McCollough, Cynthia H

    2010-01-01

    Rational and Objectives To optimize and validate projection space denoising (PSDN) strategies for application to 80 kV computed tomography (CT) data to achieve 50% dose reduction. Materials and Methods This retrospective HIPAA-compliant study had IRB approval. We utilized 80 kV image data (mean CTDIvol 7.9 mGy) obtained from dual-source dual-energy CTE exams in 42 patients. For each exam, nine 80 kV image datasets were reconstructed using PSDN (3 levels of intensity) ± image-based denoising and compared to commercial reconstruction kernels. For optimization, qualitative analysis selected optimal denoising strategies, with quantitative analysis measuring image contrast, noise and sharpness (FWHM bowel wall thickness, maximum CT number gradient). For validation, two radiologists examined image quality, comparing low-dose 80 kV optimally denoised images to full dose mixed kV images. Results PSDN algorithms generated the best 80 kV image quality (41/42 patients), while the commercial kernels produced the worst (39/42, p < 0.001). Overall 80 kV PSDN approaches resulted in higher contrast (mean 332 HU vs. 290 HU), slightly less noise (mean 20 HU vs. 26 HU), but slightly decreased images sharpness (relative bowel wall thickness, 1.069 vs. 1.000) compared to full-dose mixed kV images. Mean image quality scores for full-dose CTE images was 4.9 compared to 4.5 for optimally-denoised half-dose 80 kV CTE images, and 3.1 for non-denoised 80 kV CTE images (p<0.001). Conclusion Optimized denoising strategies improve the quality of 80 kV CT enterography images such that CT data obtained at 50% of routine dose levels approaches the image quality of full-dose exams. PMID:20832023

  10. Performance of adaptive iterative dose reduction 3D integrated with automatic tube current modulation in radiation dose and image noise reduction compared with filtered-back projection for 80-kVp abdominal CT: Anthropomorphic phantom and patient study.

    PubMed

    Chen, Chien-Ming; Lin, Yang-Yu; Hsu, Ming-Yi; Hung, Chien-Fu; Liao, Ying-Lan; Tsai, Hui-Yu

    2016-09-01

    Evaluate the performance of Adaptive Iterative Dose Reduction 3D (AIDR 3D) and compare with filtered-back projection (FBP) regarding radiation dosage and image quality for an 80-kVp abdominal CT. An abdominal phantom underwent four CT acquisitions and reconstruction algorithms (FBP; AIDR 3D mild, standard and strong). Sixty-three patients underwent unenhanced liver CT with FBP and standard level AIDR 3D. Further post-acquisition reconstruction with strong level AIDR 3D was made. Patients were divided into two groups (< and ≧29cm) based on the abdominal effective diameter (Deff) at T12 level. Quantitative (attenuation, noise, and signal-to-noise ratio) and qualitative (image quality, noise, sharpness, and artifact) analysis by two readers were assessed and the interobserver agreement was calculated. Strong level AIDR 3D reduced radiation dose by 72% in the phantom and 47.1% in the patient study compared with FBP. There was no difference in mean attenuations. Image noise was the lowest and signal-to-noise ratio the highest using strong level AIDR 3D in both patient groups. For Deff<29cm, image sharpness of FBP was significantly different from those of AIDR 3D (P<0.05). For Deff ≧29cm, image quality of AIDR 3D was significantly more favorable than FBP (P<0.05). Interobserver agreement was substantial. Integrated AIDR 3D allows for an automatic reduction in radiation dose and maintenance of image quality compared with FBP. Using AIDR 3D reconstruction, patients with larger abdomen circumference could be imaged at 80kVp. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Radiation dose reduction in computed tomography: techniques and future perspective

    PubMed Central

    Yu, Lifeng; Liu, Xin; Leng, Shuai; Kofler, James M; Ramirez-Giraldo, Juan C; Qu, Mingliang; Christner, Jodie; Fletcher, Joel G; McCollough, Cynthia H

    2011-01-01

    Despite universal consensus that computed tomography (CT) overwhelmingly benefits patients when used for appropriate indications, concerns have been raised regarding the potential risk of cancer induction from CT due to the exponentially increased use of CT in medicine. Keeping radiation dose as low as reasonably achievable, consistent with the diagnostic task, remains the most important strategy for decreasing this potential risk. This article summarizes the general technical strategies that are commonly used for radiation dose management in CT. Dose-management strategies for pediatric CT, cardiac CT, dual-energy CT, CT perfusion and interventional CT are specifically discussed, and future perspectives on CT dose reduction are presented. PMID:22308169

  12. Radiation dose reduction in computed tomography: techniques and future perspective.

    PubMed

    Yu, Lifeng; Liu, Xin; Leng, Shuai; Kofler, James M; Ramirez-Giraldo, Juan C; Qu, Mingliang; Christner, Jodie; Fletcher, Joel G; McCollough, Cynthia H

    2009-10-01

    Despite universal consensus that computed tomography (CT) overwhelmingly benefits patients when used for appropriate indications, concerns have been raised regarding the potential risk of cancer induction from CT due to the exponentially increased use of CT in medicine. Keeping radiation dose as low as reasonably achievable, consistent with the diagnostic task, remains the most important strategy for decreasing this potential risk. This article summarizes the general technical strategies that are commonly used for radiation dose management in CT. Dose-management strategies for pediatric CT, cardiac CT, dual-energy CT, CT perfusion and interventional CT are specifically discussed, and future perspectives on CT dose reduction are presented.

  13. Regularized ML reconstruction for time/dose reduction in 18F-fluoride PET/CT studies

    NASA Astrophysics Data System (ADS)

    De Bernardi, Elisabetta; Magnani, Patrizia; Gianolli, Luigi; Carla Gilardi, Maria; Bettinardi, Valentino

    2015-01-01

    We are proposing a regularized reconstruction strategy for the detection of bone lesions in 18F-fluoride whole body PET images obtained with 1 min/bed using the anatomical information provided by co-registered CT images. Bones are recognized on CT images and then transposed into the PET volume framework. During PET reconstruction, two different priors are used for bone and non-bone voxels: the relative difference prior in bone and the P-Gaussian prior in non-bone. After a tuning of the priors’ parameters, the reconstruction strategy has been tested on 6 18F-fluoride PET/CT studies, on a total of 67 lesions. Regularized images provided results comparable to the standard 3 min/bed images, in terms image quality, lesion activity, noise level and noise correlation. The proposed strategy therefore appears to be a useful tool to reduce the acquisition time or the injected dose in 18F-fluoride PET studies.

  14. Automated Tube Voltage Selection for Radiation Dose Reduction in CT Angiography Using Different Contrast Media Concentrations and a Constant Iodine Delivery Rate.

    PubMed

    Kok, Madeleine; Mihl, Casper; Seehofnerová, Anna; Turek, Jakub; Jost, Gregor; Pietsch, Hubertus; Haberland, Ulrike; Wildberger, Joachim E; Das, Marco

    2015-12-01

    The purpose of this study was to systematically investigate radiation dose reduction using automated tube voltage selection during CT angiography (CTA) and to evaluate the impact of contrast medium (CM) injection protocols on dose reduction. A circulation phantom containing the thoracic and abdominal vasculature was used. Four different concentrations of CM (iopromide 300 and 370 mg I/mL and iomeprol 350 and 400 mg I/mL) were administered while maintaining an identical iodine delivery rate (1.8 g I/s) and total iodine load (20.0 g). Three different scanning protocols for CTA of the thoracoabdominal aorta were used: protocol A, no dose modulation; protocol B, automated tube current modulation (CARE Dose4D); and protocol C, automated tube voltage selection (CARE kV). The dose-length product was recorded to calculate the effective dose. Attenuation values (in Hounsfield units), image noise levels, and signal-to-noise ratios (SNRs) in six predefined intravascular sites (three thoracic and three abdominal) were measured by two readers. All values were analyzed using the Kruskal-Wallis test and two-way ANOVA. There was a significant reduction in the effective dose (in millisieverts) for protocols B (mean ± SD, 2.03 ± 0.1 mSv) and C (1.00 ± 0.0 mSv) compared with protocol A (4.34 ± 0.0 mSv). The dose was reduced by 53% for protocol B and by 77% for protocol C. No significant differences were found in the effective dose among the different CM injection protocols within the scanning protocols; all p values were > 0.05. The attenuation values and SNRs were comparable among all the different CM injection protocols; all p values were > 0.05. A large radiation dose reduction (77%) can be achieved using automated tube voltage selection independent of the CM injection protocol.

  15. SU-E-I-62: Assessing Radiation Dose Reduction and CT Image Optimization Through the Measurement and Analysis of the Detector Quantum Efficiency (DQE) of CT Images Using Different Beam Hardening Filters

    SciTech Connect

    Collier, J; Aldoohan, S; Gill, K

    2014-06-01

    Purpose: Reducing patient dose while maintaining (or even improving) image quality is one of the foremost goals in CT imaging. To this end, we consider the feasibility of optimizing CT scan protocols in conjunction with the application of different beam-hardening filtrations and assess this augmentation through noise-power spectrum (NPS) and detector quantum efficiency (DQE) analysis. Methods: American College of Radiology (ACR) and Catphan phantoms (The Phantom Laboratory) were scanned with a 64 slice CT scanner when additional filtration of thickness and composition (e.g., copper, nickel, tantalum, titanium, and tungsten) had been applied. A MATLAB-based code was employed to calculate the image of noise NPS. The Catphan Image Owl software suite was then used to compute the modulated transfer function (MTF) responses of the scanner. The DQE for each additional filter, including the inherent filtration, was then computed from these values. Finally, CT dose index (CTDIvol) values were obtained for each applied filtration through the use of a 100 mm pencil ionization chamber and CT dose phantom. Results: NPS, MTF, and DQE values were computed for each applied filtration and compared to the reference case of inherent beam-hardening filtration only. Results showed that the NPS values were reduced between 5 and 12% compared to inherent filtration case. Additionally, CTDIvol values were reduced between 15 and 27% depending on the composition of filtration applied. However, no noticeable changes in image contrast-to-noise ratios were noted. Conclusion: The reduction in the quanta noise section of the NPS profile found in this phantom-based study is encouraging. The reduction in both noise and dose through the application of beam-hardening filters is reflected in our phantom image quality. However, further investigation is needed to ascertain the applicability of this approach to reducing patient dose while maintaining diagnostically acceptable image qualities in a

  16. Variability in CT lung-nodule quantification: Effects of dose reduction and reconstruction methods on density and texture based features

    PubMed Central

    Lo, P.; Young, S.; Kim, H. J.; Brown, M. S.

    2016-01-01

    Purpose: To investigate the effects of dose level and reconstruction method on density and texture based features computed from CT lung nodules. Methods: This study had two major components. In the first component, a uniform water phantom was scanned at three dose levels and images were reconstructed using four conventional filtered backprojection (FBP) and four iterative reconstruction (IR) methods for a total of 24 different combinations of acquisition and reconstruction conditions. In the second component, raw projection (sinogram) data were obtained for 33 lung nodules from patients scanned as a part of their clinical practice, where low dose acquisitions were simulated by adding noise to sinograms acquired at clinical dose levels (a total of four dose levels) and reconstructed using one FBP kernel and two IR kernels for a total of 12 conditions. For the water phantom, spherical regions of interest (ROIs) were created at multiple locations within the water phantom on one reference image obtained at a reference condition. For the lung nodule cases, the ROI of each nodule was contoured semiautomatically (with manual editing) from images obtained at a reference condition. All ROIs were applied to their corresponding images reconstructed at different conditions. For 17 of the nodule cases, repeat contours were performed to assess repeatability. Histogram (eight features) and gray level co-occurrence matrix (GLCM) based texture features (34 features) were computed for all ROIs. For the lung nodule cases, the reference condition was selected to be 100% of clinical dose with FBP reconstruction using the B45f kernel; feature values calculated from other conditions were compared to this reference condition. A measure was introduced, which the authors refer to as Q, to assess the stability of features across different conditions, which is defined as the ratio of reproducibility (across conditions) to repeatability (across repeat contours) of each feature. Results: The

  17. Noise reduction for low-dose helical CT by 3D penalized weighted least-squares sinogram smoothing

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Li, Tianfang; Lu, Hongbing; Liang, Zhengrong

    2006-03-01

    Helical computed tomography (HCT) has several advantages over conventional step-and-shoot CT for imaging a relatively large object, especially for dynamic studies. However, HCT may increase X-ray exposure significantly to the patient. This work aims to reduce the radiation by lowering the X-ray tube current (mA) and filtering the low-mA (or dose) sinogram noise. Based on the noise properties of HCT sinogram, a three-dimensional (3D) penalized weighted least-squares (PWLS) objective function was constructed and an optimal sinogram was estimated by minimizing the objective function. To consider the difference of signal correlation among different direction of the HCT sinogram, an anisotropic Markov random filed (MRF) Gibbs function was designed as the penalty. The minimization of the objection function was performed by iterative Gauss-Seidel updating strategy. The effectiveness of the 3D-PWLS sinogram smoothing for low-dose HCT was demonstrated by a 3D Shepp-Logan head phantom study. Comparison studies with our previously developed KL domain PWLS sinogram smoothing algorithm indicate that the KL+2D-PWLS algorithm shows better performance on in-plane noise-resolution trade-off while the 3D-PLWS shows better performance on z-axis noise-resolution trade-off. Receiver operating characteristic (ROC) studies by using channelized Hotelling observer (CHO) shows that 3D-PWLS and KL+2DPWLS algorithms have similar performance on detectability in low-contrast environment.

  18. Ultra-low dose CT attenuation correction for PET/CT.

    PubMed

    Xia, Ting; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E

    2012-01-21

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging.

  19. Ultra-low dose CT attenuation correction for PET/CT

    PubMed Central

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  20. Ultra-low dose CT attenuation correction for PET/CT

    NASA Astrophysics Data System (ADS)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging.

  1. Angular on-line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction

    SciTech Connect

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John

    2007-07-15

    The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary study on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM

  2. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    PubMed

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique.

    PubMed

    Kim, Jun-Hwee; Kim, Myung-Joon; Kim, Ha Yan; Lee, Mi-Jung

    2014-01-01

    The objective of this study was to compare the radiation dose and image quality of pediatric abdominal computed tomography (CT) using a protocol reconstructed with filtered back projection (FBP) and a protocol with both kVp and mAs modulation and sinogram-affirmed iterative reconstruction (SAFIRE). We retrospectively reviewed pediatric abdominal CT examinations performed with both kVp and mAs modulation. These raw data were reconstructed with SAFIRE at different strengths from 2 to 4 (SAFIRE groups 2-4). Another set of age/sex-matched pediatric abdominal CT examinations were also reviewed, which were performed during the same period with only mAs modulation and FBP (control group). The radiation dose and image quality were compared between groups. The image quality was objectively evaluated as the noise measured in the liver, aorta, and spleen at the level of the main portal vein and the image quality was subjectively reviewed by two radiologists for diagnostic acceptability using a four-point scale (0: unacceptable; 1: worse than the control group, but acceptable; 2: comparable with the control group; and 3: better than the control group). An independent t test was used in order to compare the radiation dose. An independent t test with Bonferroni correction and generalized estimating equations were used for the comparison of the objective and subjective image quality, respectively. Twenty-nine patients (M:F=19:10; mean age, 10.0 years) were enrolled in each group. The SAFIRE group, using the size-specific dose estimates calculation method showed a 64.2% radiation dose reduction (from 8.1 to 2.9 mGy, P<.05), compared with the results of the control group. The objective image noise of the SAFIRE groups 2 and 3 was comparable to that of the control group. The subjective image quality was the best in SAFIRE group 3 [odds ratio (OR) 3.015, P<.001 when comparing to SAFIRE group 0; OR 1.513, P<.001 when comparing to SAFIRE group 2]. Image acquisition with both kVp and m

  4. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    SciTech Connect

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M

    2016-06-15

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  5. Improved dose calculation accuracy for low energy brachytherapy by optimizing dual energy CT imaging protocols for noise reduction using sinogram affirmed iterative reconstruction.

    PubMed

    Landry, Guillaume; Gaudreault, Mathieu; van Elmpt, Wouter; Wildberger, Joachim E; Verhaegen, Frank

    2016-03-01

    The goal of this study was to evaluate the noise reduction achievable from dual energy computed tomography (CT) imaging (DECT) using filtered backprojection (FBP) and iterative image reconstruction algorithms combined with increased imaging exposure. We evaluated the data in the context of imaging for brachytherapy dose calculation, where accurate quantification of electron density ρe and effective atomic number Zeff is beneficial. A dual source CT scanner was used to scan a phantom containing tissue mimicking inserts. DECT scans were acquired at 80 kVp/140Sn kVp (where Sn stands for tin filtration) and 100 kVp/140Sn kVp, using the same values of the CT dose index CTDIvol for both settings as a measure for the radiation imaging exposure. Four CTDIvol levels were investigated. Images were reconstructed using FBP and sinogram affirmed iterative reconstruction (SAFIRE) with strength 1,3 and 5. From DECT scans two material quantities were derived, Zeff and ρe. DECT images were used to assign material types and the amount of improperly assigned voxels was quantified for each protocol. The dosimetric impact of improperly assigned voxels was evaluated with Geant4 Monte Carlo (MC) dose calculations for an (125)I source in numerical phantoms. Standard deviations for Zeff and ρe were reduced up to a factor ∼2 when using SAFIRE with strength 5 compared to FBP. Standard deviations on Zeff and ρe as low as 0.15 and 0.006 were achieved for the muscle insert representing typical soft tissue using a CTDIvol of 40 mGy and 3mm slice thickness. Dose calculation accuracy was generally improved when using SAFIRE. Mean (maximum absolute) dose errors of up to 1.3% (21%) with FBP were reduced to less than 1% (6%) with SAFIRE at a CTDIvol of 10 mGy. Using a CTDIvol of 40mGy and SAFIRE yielded mean dose calculation errors of the order of 0.6% which was the MC dose calculation precision in this study and no error was larger than ±2.5% as opposed to errors of up to -4% with FPB. This

  6. A high-resolution photon-counting breast CT system with tensor-framelet based iterative image reconstruction for radiation dose reduction

    NASA Astrophysics Data System (ADS)

    Ding, Huanjun; Gao, Hao; Zhao, Bo; Cho, Hyo-Min; Molloi, Sabee

    2014-10-01

    Both computer simulations and experimental phantom studies were carried out to investigate the radiation dose reduction with tensor framelet based iterative image reconstruction (TFIR) for a dedicated high-resolution spectral breast computed tomography (CT) based on a silicon strip photon-counting detector. The simulation was performed with a 10 cm-diameter water phantom including three contrast materials (polyethylene, 8 mg ml-1 iodine and B-100 bone-equivalent plastic). In the experimental study, the data were acquired with a 1.3 cm-diameter polymethylmethacrylate (PMMA) phantom containing iodine in three concentrations (8, 16 and 32 mg ml-1) at various radiation doses (1.2, 2.4 and 3.6 mGy) and then CT images were reconstructed using the filtered-back-projection (FBP) technique and the TFIR technique, respectively. The image quality between these two techniques was evaluated by the quantitative analysis on contrast-to-noise ratio (CNR) and spatial resolution that was evaluated using the task-based modulation transfer function (MTF). Both the simulation and experimental results indicated that the task-based MTF obtained from TFIR reconstruction with one-third of the radiation dose was comparable to that from the FBP reconstruction for low contrast target. For high contrast target, the TFIR was substantially superior to the FBP reconstruction in terms of spatial resolution. In addition, TFIR was able to achieve a factor of 1.6-1.8 increase in CNR, depending on the target contrast level. This study demonstrates that the TFIR can reduce the required radiation dose by a factor of two-thirds for a CT image reconstruction compared to the FBP technique. It achieves much better CNR and spatial resolution for high contrast target in addition to retaining similar spatial resolution for low contrast target. This TFIR technique has been implemented with a graphic processing unit system and it takes approximately 10 s to reconstruct a single-slice CT image

  7. A high-resolution photon-counting breast CT system with tensor-framelet based iterative image reconstruction for radiation dose reduction

    PubMed Central

    Ding, Huanjun; Gao, Hao; Zhao, Bo; Cho, Hyo-Min; Molloi, Sabee

    2016-01-01

    Both computer simulations and experimental phantom studies were carried out to investigate the radiation dose reduction with tensor framelet based iterative image reconstruction (TFIR) for a dedicated high-resolution spectral breast computed tomography (CT) based on a silicon strip photon-counting detector. The simulation was performed with a 10 cm-diameter water phantom including three contrast materials (polyethylene, 8 mg/ml iodine and B-100 bone-equivalent plastic). In the experimental study, the data were acquired with a 1.3 cm-diameter polymethylmethacrylate (PMMA) phantom containing iodine in three concentrations (8, 16 and 32 mg/ml) at various radiation doses (1.2, 2.4 and 3.6 mGy) and then CT images were reconstructed using filtered-back-projection (FBP) technique and TFIR technique, respectively. The image quality between these two techniques was evaluated by the quantitative analysis on contrast-to-noise ratio (CNR) and spatial resolution that was evaluated using the tasked-based modulation transfer function (MTF). Both simulation and experimental results indicated that the task-based MTF obtained from TFIR reconstruction with one-third of the radiation dose was comparable to that from FBP reconstruction for low contrast target. For high contrast target, TFIR was substantially superior to FBP reconstruction in term of spatial resolution. In addition, TFIR was able to achieve a factor of 1.6 to 1.8 increase in CNR depending on the target contrast level. This study demonstrates that TFIR can reduce the required radiation dose by a factor of two-third for a CT image reconstruction compared to FBP technique. It achieves much better CNR and spatial resolution for high contrast target in addition to retaining similar spatial resolution for low contrast target. This TFIR technique has been implemented with a graphic processing unit (GPU) system and it takes approximately 10 seconds to reconstruct a single-slice CT image, which can be potentially used in a

  8. A high-resolution photon-counting breast CT system with tensor-framelet based iterative image reconstruction for radiation dose reduction.

    PubMed

    Ding, Huanjun; Gao, Hao; Zhao, Bo; Cho, Hyo-Min; Molloi, Sabee

    2014-10-21

    Both computer simulations and experimental phantom studies were carried out to investigate the radiation dose reduction with tensor framelet based iterative image reconstruction (TFIR) for a dedicated high-resolution spectral breast computed tomography (CT) based on a silicon strip photon-counting detector. The simulation was performed with a 10 cm-diameter water phantom including three contrast materials (polyethylene, 8 mg ml(-1) iodine and B-100 bone-equivalent plastic). In the experimental study, the data were acquired with a 1.3 cm-diameter polymethylmethacrylate (PMMA) phantom containing iodine in three concentrations (8, 16 and 32 mg ml(-1)) at various radiation doses (1.2, 2.4 and 3.6 mGy) and then CT images were reconstructed using the filtered-back-projection (FBP) technique and the TFIR technique, respectively. The image quality between these two techniques was evaluated by the quantitative analysis on contrast-to-noise ratio (CNR) and spatial resolution that was evaluated using the task-based modulation transfer function (MTF). Both the simulation and experimental results indicated that the task-based MTF obtained from TFIR reconstruction with one-third of the radiation dose was comparable to that from the FBP reconstruction for low contrast target. For high contrast target, the TFIR was substantially superior to the FBP reconstruction in terms of spatial resolution. In addition, TFIR was able to achieve a factor of 1.6-1.8 increase in CNR, depending on the target contrast level. This study demonstrates that the TFIR can reduce the required radiation dose by a factor of two-thirds for a CT image reconstruction compared to the FBP technique. It achieves much better CNR and spatial resolution for high contrast target in addition to retaining similar spatial resolution for low contrast target. This TFIR technique has been implemented with a graphic processing unit system and it takes approximately 10 s to reconstruct a single-slice CT image

  9. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    SciTech Connect

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-11-15

    that were not adjusted by patient size. Additionally, considerable differences were noted in ED{sub adj} distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED{sub adj} (range: 9%-64%). Finally, a significant difference (up to 59%) in ED{sub adj} distributions was observed between institutions, indicating the potential for dose reduction. Conclusions: The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED{sub adj} were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.

  10. AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT.

    PubMed

    McNitt-Gray, Michael F

    2002-01-01

    This article describes basic radiation dose concepts as well as those specifically developed to describe the radiation dose from computed tomography (CT). Basic concepts of radiation dose are reviewed, including exposure, absorbed dose, and effective dose. Radiation dose from CT demonstrates variations within the scan plane and along the z axis because of its unique geometry and usage. Several CT-specific dose descriptors have been developed: the Multiple Scan Average Dose descriptor, the Computed Tomography Dose Index (CTDI) and its variations (CTDI(100), CTDI(w), CTDI(vol)), and the dose-length product. Factors that affect radiation dose from CT include the beam energy, tube current-time product, pitch, collimation, patient size, and dose reduction options. Methods of reducing the radiation dose to a patient from CT include reducing the milliampere-seconds value, increasing the pitch, varying the milliampere-seconds value according to patient size, and reducing the beam energy. The effective dose from CT can be estimated by using Monte Carlo methods to simulate CT of a mathematical patient model, by estimating the energy imparted to the body region being scanned, or by using conversion factors for general anatomic regions. Issues related to radiation dose from CT are being addressed by the Society for Pediatric Radiology, the American Association of Physicists in Medicine, the American College of Radiology, and the Center for Devices and Radiological Health of the Food and Drug Administration.

  11. The Impact of Different Levels of Adaptive Iterative Dose Reduction 3D on Image Quality of 320-Row Coronary CT Angiography: A Clinical Trial

    PubMed Central

    Feger, Sarah; Rief, Matthias; Zimmermann, Elke; Martus, Peter; Schuijf, Joanne Désirée; Blobel, Jörg; Richter, Felicitas; Dewey, Marc

    2015-01-01

    Purpose The aim of this study was the systematic image quality evaluation of coronary CT angiography (CTA), reconstructed with the 3 different levels of adaptive iterative dose reduction (AIDR 3D) and compared to filtered back projection (FBP) with quantum denoising software (QDS). Methods Standard-dose CTA raw data of 30 patients with mean radiation dose of 3.2 ± 2.6 mSv were reconstructed using AIDR 3D mild, standard, strong and compared to FBP/QDS. Objective image quality comparison (signal, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), contour sharpness) was performed using 21 measurement points per patient, including measurements in each coronary artery from proximal to distal. Results Objective image quality parameters improved with increasing levels of AIDR 3D. Noise was lowest in AIDR 3D strong (p≤0.001 at 20/21 measurement points; compared with FBP/QDS). Signal and contour sharpness analysis showed no significant difference between the reconstruction algorithms for most measurement points. Best coronary SNR and CNR were achieved with AIDR 3D strong. No loss of SNR or CNR in distal segments was seen with AIDR 3D as compared to FBP. Conclusions On standard-dose coronary CTA images, AIDR 3D strong showed higher objective image quality than FBP/QDS without reducing contour sharpness. Trial Registration Clinicaltrials.gov NCT00967876 PMID:25945924

  12. Dose Reduction Techniques

    SciTech Connect

    WAGGONER, L.O.

    2000-05-16

    As radiation safety specialists, one of the things we are required to do is evaluate tools, equipment, materials and work practices and decide whether the use of these products or work practices will reduce radiation dose or risk to the environment. There is a tendency for many workers that work with radioactive material to accomplish radiological work the same way they have always done it rather than look for new technology or change their work practices. New technology is being developed all the time that can make radiological work easier and result in less radiation dose to the worker or reduce the possibility that contamination will be spread to the environment. As we discuss the various tools and techniques that reduce radiation dose, keep in mind that the radiological controls should be reasonable. We can not always get the dose to zero, so we must try to accomplish the work efficiently and cost-effectively. There are times we may have to accept there is only so much you can do. The goal is to do the smart things that protect the worker but do not hinder him while the task is being accomplished. In addition, we should not demand that large amounts of money be spent for equipment that has marginal value in order to save a few millirem. We have broken the handout into sections that should simplify the presentation. Time, distance, shielding, and source reduction are methods used to reduce dose and are covered in Part I on work execution. We then look at operational considerations, radiological design parameters, and discuss the characteristics of personnel who deal with ALARA. This handout should give you an overview of what it takes to have an effective dose reduction program.

  13. Statistical model based iterative reconstruction in clinical CT systems. Part III. Task-based kV/mAs optimization for radiation dose reduction

    PubMed Central

    Li, Ke; Gomez-Cardona, Daniel; Hsieh, Jiang; Lubner, Meghan G.; Pickhardt, Perry J.; Chen, Guang-Hong

    2015-01-01

    Purpose: For a given imaging task and patient size, the optimal selection of x-ray tube potential (kV) and tube current-rotation time product (mAs) is pivotal in achieving the maximal radiation dose reduction while maintaining the needed diagnostic performance. Although contrast-to-noise (CNR)-based strategies can be used to optimize kV/mAs for computed tomography (CT) imaging systems employing the linear filtered backprojection (FBP) reconstruction method, a more general framework needs to be developed for systems using the nonlinear statistical model-based iterative reconstruction (MBIR) method. The purpose of this paper is to present such a unified framework for the optimization of kV/mAs selection for both FBP- and MBIR-based CT systems. Methods: The optimal selection of kV and mAs was formulated as a constrained optimization problem to minimize the objective function, Dose(kV,mAs), under the constraint that the achievable detectability index d′(kV,mAs) is not lower than the prescribed value of d℞′ for a given imaging task. Since it is difficult to analytically model the dependence of d′ on kV and mAs for the highly nonlinear MBIR method, this constrained optimization problem is solved with comprehensive measurements of Dose(kV,mAs) and d′(kV,mAs) at a variety of kV–mAs combinations, after which the overlay of the dose contours and d′ contours is used to graphically determine the optimal kV–mAs combination to achieve the lowest dose while maintaining the needed detectability for the given imaging task. As an example, d′ for a 17 mm hypoattenuating liver lesion detection task was experimentally measured with an anthropomorphic abdominal phantom at four tube potentials (80, 100, 120, and 140 kV) and fifteen mA levels (25 and 50–700) with a sampling interval of 50 mA at a fixed rotation time of 0.5 s, which corresponded to a dose (CTDIvol) range of [0.6, 70] mGy. Using the proposed method, the optimal kV and mA that minimized dose for the

  14. Statistical model based iterative reconstruction in clinical CT systems. Part III. Task-based kV/mAs optimization for radiation dose reduction.

    PubMed

    Li, Ke; Gomez-Cardona, Daniel; Hsieh, Jiang; Lubner, Meghan G; Pickhardt, Perry J; Chen, Guang-Hong

    2015-09-01

    For a given imaging task and patient size, the optimal selection of x-ray tube potential (kV) and tube current-rotation time product (mAs) is pivotal in achieving the maximal radiation dose reduction while maintaining the needed diagnostic performance. Although contrast-to-noise (CNR)-based strategies can be used to optimize kV/mAs for computed tomography (CT) imaging systems employing the linear filtered backprojection (FBP) reconstruction method, a more general framework needs to be developed for systems using the nonlinear statistical model-based iterative reconstruction (MBIR) method. The purpose of this paper is to present such a unified framework for the optimization of kV/mAs selection for both FBP- and MBIR-based CT systems. The optimal selection of kV and mAs was formulated as a constrained optimization problem to minimize the objective function, Dose(kV,mAs), under the constraint that the achievable detectability index d'(kV,mAs) is not lower than the prescribed value of d'R for a given imaging task. Since it is difficult to analytically model the dependence of d' on kV and mAs for the highly nonlinear MBIR method, this constrained optimization problem is solved with comprehensive measurements of Dose(kV,mAs) and d'(kV,mAs) at a variety of kV-mAs combinations, after which the overlay of the dose contours and d' contours is used to graphically determine the optimal kV-mAs combination to achieve the lowest dose while maintaining the needed detectability for the given imaging task. As an example, d' for a 17 mm hypoattenuating liver lesion detection task was experimentally measured with an anthropomorphic abdominal phantom at four tube potentials (80, 100, 120, and 140 kV) and fifteen mA levels (25 and 50-700) with a sampling interval of 50 mA at a fixed rotation time of 0.5 s, which corresponded to a dose (CTDIvol) range of [0.6, 70] mGy. Using the proposed method, the optimal kV and mA that minimized dose for the prescribed detectability level of d'R=16

  15. Radiation dose measurements in coronary CT angiography

    PubMed Central

    Sabarudin, Akmal; Sun, Zhonghua

    2013-01-01

    Coronary computed tomography (CT) angiography is associated with high radiation dose and this has raised serious concerns in the literature. Awareness of various parameters for dose estimates and measurements of coronary CT angiography plays an important role in increasing our understanding of the radiation exposure to patients, thus, contributing to the implementation of dose-saving strategies. This article provides an overview of the radiation dose quantity and its measurement during coronary CT angiography procedures. PMID:24392190

  16. Coronary CT angiography with low radiation dose.

    PubMed

    Xu, Lei; Zhang, Zhaoqi

    2010-02-01

    With the introduction of 64-slice CT and dual-source CT technology, coronary CT angiography(CCTA) has emerged as a useful diagnostic imaging modality for the noninvasive assessment of coronary heart disease. Recently, the risks associated with ionizing radiation on CT have raised serious concerns.The main concern of exposure to ionizing radiation is the potential risk of cancer. CCTA involves much higher radiation dose with the advances in the spatial and temporal resolution of cardiac CT. Currently,various dose-saving algorithms, such as ECG (electrocardiography)-based dose modulation, reduced tube voltage, and prospective ECG gating, high-pitch helical scanning are available to lower radiation exposure during cardiac CT. Therefore, careful selection of CT scanning protocols is needed to keep the radiation exposure 'as low as reasonably achievable (ALARA)'. In this review we will discuss the radiation dose safety issues, the measurement of radiation dose and current use of dose-saving techniques in CCTA.

  17. Low-dose interpolated average CT for attenuation correction in cardiac PET/CT

    NASA Astrophysics Data System (ADS)

    Wu, Tung-Hsin; Zhang, Geoffrey; Wang, Shyh-Jen; Chen, Chih-Hao; Yang, Bang-Hung; Wu, Nien-Yun; Huang, Tzung-Chi

    2010-07-01

    Because of the advantages in the use of high photon flux and thus the short scan times of CT imaging, the traditional 68Ge scans for positron emission tomography (PET) image attenuation correction have been replaced by CT scans in the modern PET/CT technology. The combination of fast CT scan and slow PET scan often causes image misalignment between the PET and CT images due to respiration motion. Use of the average CT derived from cine CT images is reported to reduce such misalignment. However, the radiation dose to patients is higher with cine CT scans. This study introduces a method that uses breath-hold CT images and their interpolations to generate the average CT for PET image attenuation correction. Breath-hold CT sets are taken at end-inspiration and end-expiration. Deformable image registration is applied to generate a voxel-to-voxel motion matrix between the two CT sets. The motion is equally divided into 5 steps from inspiration to expiration and 5 steps from expiration to inspiration, generating a total of 8 phases of interpolated CT sets. An average CT image is generated from all the 10 phase CT images, including original inhale/exhale CT and 8 interpolated CT sets. Quantitative comparison shows that the reduction of image misalignment artifacts using the average CT from the interpolation technique for PET attenuation correction is at a similar level as that using cine average CT, while the dose to the patient from the CT scans is reduced significantly. The interpolated average CT method hence provides a low dose alternative to cine CT scans for PET attenuation correction.

  18. Low-dose techniques in CT-guided interventions.

    PubMed

    Sarti, Marc; Brehmer, William P; Gay, Spencer B

    2012-01-01

    Computed tomography (CT)-guided interventions such as biopsy, drainage, and ablation may be significant sources of radiation exposure in both patients and radiologists. Simple CT techniques to reduce radiation dose may be employed without increasing the procedure time or significantly degrading image quality. To develop low-dose protocols, it is important to understand the key concepts of delivered radiation dose to patients and physicians during CT-guided interventions. Patient dose estimates are easily followed and are provided at CT workstations. Familiarity with dose estimates, which are expressed as CT dose index and dose-length product, is also important. Methods to reduce radiation exposure in patients and physicians include performing proper preprocedure planning and paying careful attention to technique during the planning stage, making use of personal protective equipment, performing CT fluoroscopy intermittently instead of in real time, and optimizing needle visualization. Representative examples of these techniques have resulted in dose reductions of as much as 89%. Alternative imaging technologies that do not use ionizing radiation, such as virtual and ultrasonographic guidance, may also be used to reduce radiation dose. Understanding dose contribution strategies to reduce radiation dose provides a safer, more efficient environment for patients and the radiology team.

  19. Contrast material and radiation dose reduction strategy for triple-rule-out cardiac CT angiography: feasibility study of non-ECG-gated low kVp scan of the whole chest following coronary CT angiography.

    PubMed

    Kidoh, Masafumi; Nakaura, Takeshi; Nakamura, Shinichi; Namimoto, Tomohiro; Nozaki, Toshimitsu; Sakaino, Naritsugu; Harada, Kazunori; Yamashita, Yasuyuki

    2014-12-01

    Dedicated coronary computed tomography (CT) scan has been proven to be an accurate diagnostic modality in evaluating coronary artery disease. A second phase scan starting immediately after the coronary CT scan might enable visualization of the different vascular territories of the entire chest. To investigate the feasibility of a contrast material and radiation dose reduction triple-rule-out (TRO) CT angiography (CTA) protocol with serial non-ECG-gated low kVp scan of the whole chest, which utilizes a recirculated contrast agent. Thirty patients were scanned with the new TRO-CTA protocol; after the coronary scan with retrospective ECG-gating, non-ECG-gated whole-chest CTA was performed at 80 kVp to evaluate aortic arch (AAr) and pulmonary trunk (PT). Another 30 patients were scanned by our conventional TRO-CTA protocol at 120 kVp with retrospective ECG-gating. We compared the estimated effective dose (ED), contrast material (CM) dose, contrast-to-noise ratio (CNR) of the ascending aorta (AAo), and the rate of patients who could achieve adequate attenuation of the AAr and PT between the two protocols. The total ED of the new TRO-CTA protocol was 29.6% lower than that of the conventional protocol (P < 0.01). The amount of CM used for the new TRO-CTA protocol was significantly lower than in the conventional protocol (60.1 ± 9.6 mL vs. 91.8 ± 22.6 mL, P < 0.01). The CNR of the AAo was 30.2% higher with the new TRO-CTA protocol than with the conventional protocol (P < 0.01). There was no significant difference in the success rate of adequate attenuation of the AAr and PT between the two protocols (P > 0.05). The new TRO-CTA protocol can reduce the total dose of radiation and the contrast dose and yield adequate vascular enhancement compared with the conventional protocol. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. TU-EF-204-09: A Preliminary Method of Risk-Informed Optimization of Tube Current Modulation for Dose Reduction in CT

    SciTech Connect

    Gao, Y; Liu, B; Kalra, M; Caracappa, P; Liu, T; Li, X; Xu, X

    2015-06-15

    Purpose: X-rays from CT scans can increase cancer risk to patients. Lifetime Attributable Risk of Cancer Incidence for adult patients has been investigated and shown to decrease as patient age. However, a new risk model shows an increasing risk trend for several radiosensitive organs for middle age patients. This study investigates the feasibility of a general method for optimizing tube current modulation (TCM) functions to minimize risk by reducing radiation dose to radiosensitive organs of patients. Methods: Organ-based TCM has been investigated in literature for eye lens dose and breast dose. Adopting the concept in organ-based TCM, this study seeks to find an optimized tube current for minimal total risk to breasts and lungs by reducing dose to these organs. The contributions of each CT view to organ dose are determined through simulations of CT scan view-by-view using a GPU-based fast Monte Carlo code, ARCHER. A Linear Programming problem is established for tube current optimization, with Monte Carlo results as weighting factors at each view. A pre-determined dose is used as upper dose boundary, and tube current of each view is optimized to minimize the total risk. Results: An optimized tube current is found to minimize the total risk of lungs and breasts: compared to fixed current, the risk is reduced by 13%, with breast dose reduced by 38% and lung dose reduced by 7%. The average tube current is maintained during optimization to maintain image quality. In addition, dose to other organs in chest region is slightly affected, with relative change in dose smaller than 10%. Conclusion: Optimized tube current plans can be generated to minimize cancer risk to lungs and breasts while maintaining image quality. In the future, various risk models and greater number of projections per rotation will be simulated on phantoms of different gender and age. National Institutes of Health R01EB015478.

  1. Toward time resolved 4D cardiac CT imaging with patient dose reduction: estimating the global heart motion

    NASA Astrophysics Data System (ADS)

    Taguchi, Katsuyuki; Segars, W. Paul; Fung, George S. K.; Tsui, Benjamin M. W.

    2006-03-01

    Coronary artery imaging with multi-slice helical computed tomography is a promising noninvasive imaging technique. The current major issues include the insufficient temporal resolution and large patient dose. We propose an image reconstruction method which provides a solution to both of the problems. The method uses an iterative approach repeating the following four steps until the difference between the two projection data sets falls below a certain criteria in step-4: 1) estimating or updating the cardiac motion vectors, 2) reconstructing the time-resolved 4D dynamic volume images using the motion vectors, 3) calculating the projection data from the current 4D images, 4) comparing them with the measured ones. In this study, we obtain the first estimate of the motion vector. We use the 4D NCAT phantom, a realistic computer model for the human anatomy and cardiac motions, to generate the dynamic fan-beam projection data sets as well to provide a known truth for the motion. Then, the halfscan reconstruction with the sliding time-window technique is used to generate cine images: f(t, r r). Here, we use one heart beat for each position r so that the time information is retained. Next, the magnitude of the first derivative of f(t, r r) with respect to time, i.e., |df/dt|, is calculated and summed over a region-of-interest (ROI), which is called the mean-absolute difference (MAD). The initial estimation of the vector field are obtained using MAD for each ROI. Results of the preliminary study are presented.

  2. Low-dose CT via convolutional neural network

    PubMed Central

    Chen, Hu; Zhang, Yi; Zhang, Weihua; Liao, Peixi; Li, Ke; Zhou, Jiliu; Wang, Ge

    2017-01-01

    In order to reduce the potential radiation risk, low-dose CT has attracted an increasing attention. However, simply lowering the radiation dose will significantly degrade the image quality. In this paper, we propose a new noise reduction method for low-dose CT via deep learning without accessing original projection data. A deep convolutional neural network is here used to map low-dose CT images towards its corresponding normal-dose counterparts in a patch-by-patch fashion. Qualitative results demonstrate a great potential of the proposed method on artifact reduction and structure preservation. In terms of the quantitative metrics, the proposed method has showed a substantial improvement on PSNR, RMSE and SSIM than the competing state-of-art methods. Furthermore, the speed of our method is one order of magnitude faster than the iterative reconstruction and patch-based image denoising methods. PMID:28270976

  3. Radiation dose reduction in thoracic and lumbar spine instrumentation using navigation based on an intraoperative cone beam CT imaging system: a prospective randomized clinical trial.

    PubMed

    Pireau, Nathalie; Cordemans, Virginie; Banse, Xavier; Irda, Nadia; Lichtherte, Sébastien; Kaminski, Ludovic

    2017-07-22

    Spine surgery still remains a challenge for every spine surgeon, aware of the potential serious outcomes of misplaced instrumentation. Though many studies have highlighted that using intraoperative cone beam CT imaging and navigation systems provides higher accuracy than conventional freehand methods for placement of pedicle screws in spine surgery, few studies are concerned about how to reduce radiation exposure for patients with the use of such technology. One of the main focuses of this study is based on the ALARA principle (as low as reasonably achievable). A prospective randomized trial was conducted in the hybrid operating room between December 2015 and December 2016, including 50 patients operated on for posterior instrumented thoracic and/or lumbar spinal fusion. Patients were randomized to intraoperative 3D acquisition high-dose (standard dose) or low-dose protocol, and a total of 216 pedicle screws were analyzed in terms of screw position. Two different methods were used to measure ionizing radiation: the total skin dose (derived from the dose-area product) and the radiation dose evaluated by thermoluminescent dosimeters on the surgical field. According to Gertzbein and Heary classifications, low-dose protocol provided a significant higher accuracy of pedicle screw placement than the high-dose protocol (96.1 versus 92%, respectively). Seven screws (3.2%), all implanted with the high-dose protocol, needed to be revised intraoperatively. The use of low-dose acquisition protocols reduced patient exposure by a factor of five. This study emphasizes the paramount importance of using low-dose protocols for intraoperative cone beam CT imaging coupled with the navigation system, as it at least does not affect the accuracy of pedicle screw placement and irradiates drastically less.

  4. MO-F-CAMPUS-I-04: Patient Eye-Lens Dose Reduction in Routine Brain CT Examinations Using Organ-Based Tube Current Modulation and In-Plane Bismuth Shielding

    SciTech Connect

    Tsai, Hui-Yu; Liao, Ying-Lan; Chen, Jun-Rong

    2015-06-15

    Purpose: The purpose of this study is to assess eye-lens dose for patients who underwent brain CT examinations using two dose reduction Methods: organ-based tube current modulation (OBTCM) and in-plane bismuth shielding method. Methods: This study received institutional review board approval; written informed consent to participate was obtained from all patients. Ninety patients who underwent the routine brain CT examination were randomly assigned to three groups, ie. routine, OBTCM, and bismuth shield. The OBTCM technique reduced the tube current when the X-ray tube rotates in front of patients’ eye-lens region. The patients in the bismuth shield group were covered one-ply bismuth shield in the eyes’ region. Eye-lens doses were measured using TLD-100H chips and the total effective doses were calculated using CT-Expo according to the CT scanning parameters. The surface doses for patients at off-center positions were assessed to evaluate the off-centering effect. Results: Phantom measurements indicates that OBTCM technique could reduced by 26% to 28% of the surface dose to the eye lens, and increased by 25% of the surface dose at the opposed incident direction at the angle of 180°. Patients’ eye-lens doses were reduced 16.9% and 30.5% dose of bismuth shield scan and OBTCM scan, respectively compared to the routine scan. The eye-lens doses were apparently increased when the table position was lower than isocenter. Conclusion: Reducing the dose to the radiosensitive organs, such as eye lens, during routine brain CT examinations could lower the radiation risks. The OBTCM technique and in-plane bismuth shielding could be used to reduce the eye-lens dose. The eye-lens dose could be effectively reduced using OBTCM scan without interfering the diagnostic image quality. Patient position relative the CT gantry also affects the dose level of the eye lens. This study was supported by the grants from the Ministry of Science and Technology of Taiwan (MOST103-2314-B-182

  5. SU-F-R-39: Effects of Radiation Dose Reduction On Renal Cell Carcinoma Discrimination Using Multi-Phasic CT Imaging

    SciTech Connect

    Wahi-Anwar, M; Young, S; Lo, P; Raman, S; Kim, H; Brown, M; McNitt-Gray, M; Coy, H; Ashen-Garry, D; Pace-Soler, E

    2016-06-15

    Purpose: A method to discriminate different types of renal cell carcinoma (RCC) was developed using attenuation values observed in multiphasic contrast-enhanced CT. This work evaluates the sensitivity of this RCC discrimination task at different CT radiation dose levels. Methods: We selected 5 cases of kidney lesion patients who had undergone four-phase CT scans covering the abdomen to the lilac crest. Through an IRB-approved study, the scans were conducted on 64-slice CT scanners (Definition AS/Definition Flash, Siemens Healthcare) using automatic tube-current modulation (TCM). The protocol included an initial baseline unenhanced scan, followed by three post-contrast injection phases. CTDIvol (32 cm phantom) measured between 9 to 35 mGy for any given phase. As a preliminary study, we limited the scope to the cortico-medullary phase—shown previously to be the most discriminative phase. A previously validated method was used to simulate a reduced dose acquisition via adding noise to raw CT sinogram data, emulating corresponding images at simulated doses of 50%, 25%, and 10%. To discriminate the lesion subtype, ROIs were placed in the most enhancing region of the lesion. The mean HU value of an ROI was extracted and used to discriminate to the worst-case RCC subtype, ranked in the order of clear cell, papillary, chromophobe and the benign oncocytoma. Results: Two patients exhibited a change of worst case RCC subtype between original and simulated scans, at 25% and 10% doses. In one case, the worst-case RCC subtype changed from oncocytoma to chromophobe at 10% and 25% doses, while the other case changed from oncocytoma to clear cell at 10% dose. Conclusion: Based on preliminary results from an initial cohort of 5 patients, worst-case RCC subtypes remained constant at all simulated dose levels except for 2 patients. Further study conducted on more patients will be needed to confirm our findings. Institutional research agreement, Siemens Healthcare; Past recipient

  6. Strategies to reduce radiation dose in cardiac PET/CT

    NASA Astrophysics Data System (ADS)

    Wu, Tung Hsin; Wu, Nien-Yun; Wang, Shyh-Jen; Wu, Jay; S. P. Mok, Greta; Yang, Ching-Ching; Huang, Tzung-Chi

    2011-08-01

    Our aim was to investigate CT dose reduction strategies on a hybrid PET/CT scanner for cardiac applications.MaterialsImage quality and dose estimation of different CT scanning protocols for CT coronary angiography (CTCA), and CT-based attenuation correction for PET imaging were investigated. Fifteen patients underwent CTCA, perfusion PET imaging at rest and under stress, and FDG PET for myocardial viability. These patients were divided into three groups based on the CTCA technique performed: retrospectively gated helical (RGH), ECG tube current modulation (ETCM), and prospective gated axial (PGA) acquisitions. All emission images were corrected for photon attenuation using CT images obtained by default setting and an ultra-low dose CT (ULDCT) scan.ResultsRadiation dose in RGH technique was 22.2±4.0 mSv. It was reduced to 10.95±0.82 and 4.13±0.31 mSv using ETCM and PGA techniques, respectively. Radiation dose in CT transmission scan was reduced by 96.5% (from 4.53±0.5 to 0.16±0.01 mSv) when applying ULDCT as compared to the default CT. No significant difference in terms of image quality was found among various protocols.ConclusionThe proposed CT scanning strategies, i.e. ETCM or PGA for CTCA and ULDCT for PET attenuation correction, could reduce radiation dose up to 47% without degrading imaging quality in an integrated cardiac PET/CT coronary artery examination.

  7. Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.

    PubMed

    Rompel, Oliver; Glöckler, Martin; Janka, Rolf; Dittrich, Sven; Cesnjevar, Robert; Lell, Michael M; Uder, Michael; Hammon, Matthias

    2016-04-01

    Many technical updates have been made in multi-detector CT. To evaluate image quality and radiation dose of high-pitch second- and third-generation dual-source chest CT angiography and to assess the effects of different levels of advanced modeled iterative reconstruction (ADMIRE) in newborns and children. Chest CT angiography (70 kVp) was performed in 42 children (age 158 ± 267 days, range 1-1,194 days). We evaluated subjective and objective image quality, and radiation dose with filtered back projection (FBP) and different strength levels of ADMIRE. For comparison were 42 matched controls examined with a second-generation 128-slice dual-source CT-scanner (80 kVp). ADMIRE demonstrated improved objective and subjective image quality (P < .01). Mean signal/noise, contrast/noise and subjective image quality were 11.9, 10.0 and 1.9, respectively, for the 80 kVp mode and 11.2, 10.0 and 1.9 for the 70 kVp mode. With ADMIRE, the corresponding values for the 70 kVp mode were 13.7, 12.1 and 1.4 at strength level 2 and 17.6, 15.6 and 1.2 at strength level 4. Mean CTDIvol, DLP and effective dose were significantly lower with the 70-kVp mode (0.31 mGy, 5.33 mGy*cm, 0.36 mSv) compared to the 80-kVp mode (0.46 mGy, 9.17 mGy*cm, 0.62 mSv; P < .01). The third-generation dual-source CT at 70 kVp provided good objective and subjective image quality at lower radiation exposure. ADMIRE improved objective and subjective image quality.

  8. Doses metrics and patient age in CT.

    PubMed

    Huda, Walter; Tipnis, Sameer V

    2016-03-01

    The aim of this study was to investigate how effective dose and size-specific dose estimate (SSDE) change with patient age (size) for routine head and abdominal/pelvic CT examinations. Heads and abdomens of patients were modelled as a mass-equivalent cylinder of water corresponding to the patient 'effective diameter'. Head CT scans were performed at CTDIvol(S) of 40 mGy, and abdominal CT scans were performed at CTDIvol(L) of 10 mGy. Values of SSDE were obtained using conversion factors in AAPM Task Group Report 204. Age-specific scan lengths for head and abdominal CT scans obtained from the authors' clinical practice were used to estimate the dose-length product for each CT examination. Effective doses were calculated from previously published age- and sex-specific E/DLP conversion factors, based on ICRP 103 organ-weighting factors. For head CT examinations, the scan length increased from 15 cm in a newborn to 20 cm in adults, and for an abdominal/pelvic CT, the scan length increased from 20 cm in a newborn to 45 cm in adults. For head CT scans, SSDE ranged from 37.2 mGy in adults to 48.8 mGy in a newborn, an increase of 31 %. The corresponding head CT effective doses range from 1.4 mSv in adults to 5.2 mSv in a newborn, an increase of 270 %. For abdomen CT scans, SSDE ranged from 13.7 mGy in adults to 23.0 mGy in a newborn, an increase of 68 %. The corresponding abdominal CT effective doses ranged from 6.3 mSv in adults to 15.4 mSv in a newborn, an increase of 140 %. SSDE increases much less than effective dose in paediatric patients compared with adults because it does not account for scan length or scattered radiation. Size- and age-specific effective doses better quantify the total radiation received by patients in CT by explicitly accounting for all organ doses, as well as their relative radio sensitivity.

  9. Sinogram smoothing with bilateral filtering for low-dose CT

    NASA Astrophysics Data System (ADS)

    Yu, Lifeng; Manduca, Armando; Trzasko, Joshua D.; Khaylova, Natalia; Kofler, James M.; McCollough, Cynthia M.; Fletcher, Joel G.

    2008-03-01

    Optimal noise control is critical for dose reduction in CT. In this work, we investigated the use of a locally-adaptive method for noise reduction in low-dose CT. This method is based upon bilateral filtering, which smoothes the projection data using a weighted average in a local neighborhood, where the weights are determined according to both the spatial proximity and intensity similarity between the center pixel and the neighboring pixels. This filtering is locally adaptive and can preserve important edge information in the sinogram, thus without significantly sacrificing the spatial resolution. It is closely related to anisotropic diffusion, but is significantly faster. More importantly, a CT noise model can be readily incorporated in the filtering and denoising process. We have evaluated the noise-resolution properties of the bilateral filtering in a phantom study and a preliminary patient study with contrast-enhanced abdominal CT exams. The results demonstrated that bilateral filtering can achieve a better noise-resolution tradeoff than a series of commercial reconstruction kernels. This improvement on noise-resolution properties can be used for improving the image quality in low-dose CT and can also be translated to substantial dose reduction.

  10. Computing effective dose in cardiac CT

    NASA Astrophysics Data System (ADS)

    Huda, Walter; Tipnis, Sameer; Sterzik, Alexander; Schoepf, U. Joseph

    2010-07-01

    We present a method of estimating effective doses in cardiac CT that accounts for selected techniques (kV mAs-1), anatomical location of the scan and patient size. A CT dosimetry spreadsheet (ImPACT CT Patient Dosimetry Calculator) was used to estimate effective doses (E) using ICRP 103 weighting factors for a 70 kg patient undergoing cardiac CT examinations. Using dose length product (DLP) for the same scans, we obtained values of E/DLP for three CT scanners used in cardiac imaging from two vendors. E/DLP ratios were obtained as a function of the anatomical location in the chest and for x-ray tube voltages ranging from 80 to 140 kV. We also computed the ratio of the average absorbed dose in a water cylinder modeling a patient weighing W kg to the corresponding average absorbed dose in a water cylinder equivalent to a 70 kg patient. The average E/DLP for a 16 cm cardiac heart CT scan was 26 µSv (mGy cm)-1, which is about 70% higher than the current E/DLP values used for chest CT scans (i.e. 14-17 µSv (mGy cm)-1). Our cardiac E/DLP ratios are higher because the cardiac region is ~30% more radiosensitive than the chest, and use of the ICRP 103 tissue weighting factors increases cardiac CT effective doses by ~30%. Increasing the x-ray tube voltage from 80 to 140 kV increases the E/DLP conversion factor for cardiac CT by 17%. For the same incident radiation at 120 kV, doses in 45 kg adults were ~22% higher than those in 70 kg adults, whereas doses in 120 kg adults were ~28% lower. Accurate estimates of the patient effective dose in cardiac CT should use ICRP 103 tissue weighting factors, and account for a choice of scan techniques (kV mAs-1), exposed scan region, as well as patient size.

  11. CT radiation dose awareness among paediatricians.

    PubMed

    Al-Rammah, Tamader Y

    2016-08-31

    The radiation dose delivered from computed tomography (CT) scanning and the risks associated with ionising radiation are major concerns in paediatric imaging. Compared to adults, children have increased organ sensitivity and a longer expected lifetime in which cancer may develop. Therefore, it is important to investigate the awareness of paediatricians (referring physicians) regarding radiation doses and the associated risks. A multiple-choice survey was distributed among paediatricians in 8 hospitals in Riyadh, the capital of Saudi Arabia. Among the 162 respondents, only 24 (15 %) were aware of the As Low As Reasonably Achievable (ALARA) principle. Approximately half (54 %) of the respondents believed that multi-slice CT delivered a low radiation dose, and 100 (62 %) of the respondents were not aware that radiation is considered carcinogenic by the Food and Drug Administration in the United States. Among the respondents, 110 (68 %) did not have any specific education regarding radiation during their training. There was an overall underestimation (83 %) of the CT radiation dose, and 70 % thought that magnetic resonance imaging (MRI) delivered some level of ionising radiation. Among paediatricians in Saudi Arabian hospitals, there was a wide underestimation of the CT radiation dose and the associated risks for children. We should improve paediatricians' knowledge about radiation doses. Radiologists, paediatricians, radiation technologists and medical physicists should work together to optimise CT guidelines and protocols to reduce the radiation risks for children.

  12. [Dose and time dependency of "CT clearance"].

    PubMed

    Kaltenborn, H A; Klose, K J; Dexheimer, C; von Steinijans

    1989-06-01

    The contrast medium dose used in CT renal function analysis corresponds to about 1 ml/kg body weight at a measurement interval of 5 or 10 minutes. In the present study the dependence of "CT clearance" on dosage and time was examined in 12 healthy subjects. The amount of clearance was directly proportional to the employed contrast medium dose and to the length of the measurement interval. On account of the superior signal-to-noise ratio, the higher dose (1 ml/kg body weight) will continue to be preferred in future. The measurement interval can be limited to 10 minutes.

  13. Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model-based Iterative Reconstruction Algorithm.

    PubMed

    Solomon, Justin; Marin, Daniele; Roy Choudhury, Kingshuk; Patel, Bhavik; Samei, Ehsan

    2017-02-07

    Purpose To determine the effect of radiation dose and iterative reconstruction (IR) on noise, contrast, resolution, and observer-based detectability of subtle hypoattenuating liver lesions and to estimate the dose reduction potential of the IR algorithm in question. Materials and Methods This prospective, single-center, HIPAA-compliant study was approved by the institutional review board. A dual-source computed tomography (CT) system was used to reconstruct CT projection data from 21 patients into six radiation dose levels (12.5%, 25%, 37.5%, 50%, 75%, and 100%) on the basis of two CT acquisitions. A series of virtual liver lesions (five per patient, 105 total, lesion-to-liver prereconstruction contrast of -15 HU, 12-mm diameter) were inserted into the raw CT projection data and images were reconstructed with filtered back projection (FBP) (B31f kernel) and sinogram-affirmed IR (SAFIRE) (I31f-5 kernel). Image noise (pixel standard deviation), lesion contrast (after reconstruction), lesion boundary sharpness (average normalized gradient at lesion boundary), and contrast-to-noise ratio (CNR) were compared. Next, a two-alternative forced choice perception experiment was performed (16 readers [six radiologists, 10 medical physicists]). A linear mixed-effects statistical model was used to compare detection accuracy between FBP and SAFIRE and to estimate the radiation dose reduction potential of SAFIRE. Results Compared with FBP, SAFIRE reduced noise by a mean of 53% ± 5, lesion contrast by 12% ± 4, and lesion sharpness by 13% ± 10 but increased CNR by 89% ± 19. Detection accuracy was 2% higher on average with SAFIRE than with FBP (P = .03), which translated into an estimated radiation dose reduction potential (±95% confidence interval) of 16% ± 13. Conclusion SAFIRE increases detectability at a given radiation dose (approximately 2% increase in detection accuracy) and allows for imaging at reduced radiation dose (16% ± 13), while maintaining low

  14. SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT.

    PubMed

    Halliburton, Sandra S; Abbara, Suhny; Chen, Marcus Y; Gentry, Ralph; Mahesh, Mahadevappa; Raff, Gilbert L; Shaw, Leslee J; Hausleiter, Jörg

    2011-01-01

    Over the last few years, computed tomography (CT) has developed into a standard clinical test for a variety of cardiovascular conditions. The emergence of cardiovascular CT during a period of dramatic increase in radiation exposure to the population from medical procedures and heightened concern about the subsequent potential cancer risk has led to intense scrutiny of the radiation burden of this new technique. This has hastened the development and implementation of dose reduction tools and prompted closer monitoring of patient dose. In an effort to aid the cardiovascular CT community in incorporating patient-centered radiation dose optimization and monitoring strategies into standard practice, the Society of Cardiovascular Computed Tomography has produced a guideline document to review available data and provide recommendations regarding interpretation of radiation dose indices and predictors of risk, appropriate use of scanner acquisition modes and settings, development of algorithms for dose optimization, and establishment of procedures for dose monitoring.

  15. SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT

    PubMed Central

    Halliburton, Sandra S.; Abbara, Suhny; Chen, Marcus Y.; Gentry, Ralph; Mahesh, Mahadevappa; Raff, Gilbert L.; Shaw, Leslee J.; Hausleiter, Jörg

    2012-01-01

    Over the last few years, computed tomography (CT) has developed into a standard clinical test for a variety of cardiovascular conditions. The emergence of cardiovascular CT during a period of dramatic increase in radiation exposure to the population from medical procedures and heightened concern about the subsequent potential cancer risk has led to intense scrutiny of the radiation burden of this new technique. This has hastened the development and implementation of dose reduction tools and prompted closer monitoring of patient dose. In an effort to aid the cardiovascular CT community in incorporating patient-centered radiation dose optimization and monitoring strategies into standard practice, the Society of Cardiovascular Computed Tomography has produced a guideline document to review available data and provide recommendations regarding interpretation of radiation dose indices and predictors of risk, appropriate use of scanner acquisition modes and settings, development of algorithms for dose optimization, and establishment of procedures for dose monitoring. PMID:21723512

  16. Simulation center training as a means to improve resident performance in percutaneous noncontinuous CT-guided fluoroscopic procedures with dose reduction.

    PubMed

    Mendiratta-Lala, Mishal; Williams, Todd R; Mendiratta, Vivek; Ahmed, Hafeez; Bonnett, John W

    2015-04-01

    The purpose of this study was to evaluate the effectiveness of a multifaceted simulation-based resident training for CT-guided fluoroscopic procedures by measuring procedural and technical skills, radiation dose, and procedure times before and after simulation training. A prospective analysis included 40 radiology residents and eight staff radiologists. Residents took an online pretest to assess baseline procedural knowledge. Second-through fourth-year residents' baseline technical skills with a procedural phantom were evaluated. First-through third-year residents then underwent formal didactic and simulation-based procedural and technical training with one of two interventional radiologists and followed the training with 1 month of supervised phantom-based practice. Thereafter, residents underwent final written and practical examinations. The practical examination included essential items from a 20-point checklist, including site and side marking, consent, time-out, and sterile technique along with a technical skills portion assessing pedal steps, radiation dose, needle redirects, and procedure time. The results indicated statistically significant improvement in procedural and technical skills after simulation training. For residents, the median number of pedal steps decreased by three (p=0.001), median dose decreased by 15.4 mGy (p<0.001), median procedure time decreased by 4.0 minutes (p<0.001), median number of needle redirects decreased by 1.0 (p=0.005), and median number of 20-point checklist items successfully completed increased by three (p<0.001). The results suggest that procedural skills can be acquired and improved by simulation-based training of residents, regardless of experience. CT simulation training decreases procedural time, decreases radiation dose, and improves resident efficiency and confidence, which may transfer to clinical practice with improved patient care and safety.

  17. Dose Reduction with Adaptive Bolus Chasing Computed Tomography Angiography

    PubMed Central

    Cai, Zhijun; Bai, Er-Wei; Wang, Ge; Sharafuddin, Melhem J.; Abada, Hicham T.

    2010-01-01

    Computed Tomography (CT) has become an effective diagnosis and evaluating tool in clinical; however, its radiation exposure has drawn great attention as more and more CT scans are performed every year. How to reduce the radiation dose and meanwhile keep the resultant CT images diagnosable becomes an important research topic. In this paper, we propose a dose reduction approach along with the adaptive bolus chasing CT Angiography (CTA) techniques, which are capable of tracking the contrast bolus peak over all the blood vessel segments during the CTA scan. By modulating the tube current (and collimator width) online, we can reduce the total radiation dose and maintain the contrast to noise ratio (CNR) of the blood vessel. Numerical experiments on reference DSA data sets show that by using the proposed dose reduction method, the effective radiation dose can be saved about 39%. PMID:20421701

  18. Dose reduction with adaptive bolus chasing computed tomography angiography.

    PubMed

    Cai, Zhijun; Bai, Er-Wei; Wang, Ge; Sharafuddin, Melhem J; Abada, Hicham T

    2010-01-01

    Computed Tomography (CT) has become an effective diagnosis and evaluating tool in clinical; however, its radiation exposure has drawn great attention as more and more CT scans are performed every year. How to reduce the radiation dose and meanwhile keep the resultant CT images diagnosable becomes an important research topic. In this paper, we propose a dose reduction approach along with the adaptive bolus chasing CT Angiography (CTA) techniques, which are capable of tracking the contrast bolus peak over all the blood vessel segments during the CTA scan. By modulating the tube current (and collimator width) online, we can reduce the total radiation dose and maintain the contrast to noise ratio (CNR) of the blood vessel. Numerical experiments on reference DSA data sets show that by using the proposed dose reduction method, the effective radiation dose can be saved about 39%.

  19. Patient radiation doses for electron beam CT

    SciTech Connect

    Castellano, Isabel A.; Dance, David R.; Skinner, Claire L.; Evans, Phil M.

    2005-08-15

    A Monte Carlo based computer model has been developed for electron beam computed tomography (EBCT) to calculate organ and effective doses in a humanoid hermaphrodite phantom. The program has been validated by comparison with experimental measurements of the CT dose index in standard head and body CT dose phantoms; agreement to better than 8% has been found. The robustness of the model has been established by varying the input parameters. The amount of energy deposited at the 12:00 position of the standard body CT dose phantom is most susceptible to rotation angle, whereas that in the central region is strongly influenced by the beam quality. The program has been used to investigate the changes in organ absorbed doses arising from partial and full rotation about supine and prone subjects. Superficial organs experience the largest changes in absorbed dose with a change in subject orientation and for partial rotation. Effective doses for typical clinical scan protocols have been calculated and compared with values obtained using existing dosimetry techniques based on full rotation. Calculations which make use of Monte Carlo conversion factors for the scanner that best matches the EBCT dosimetric characteristics consistently overestimate the effective dose in supine subjects by typically 20%, and underestimate the effective dose in prone subjects by typically 13%. These factors can therefore be used to correct values obtained in this way. Empirical dosimetric techniques based on the dose-length product yield errors as great as 77%. This is due to the sensitivity of the dose length product to individual scan lengths. The magnitude of these errors is reduced if empirical dosimetric techniques based on the average absorbed dose in the irradiated volume (CTDI{sub vol}) are used. Therefore conversion factors specific to EBCT have been calculated to convert the CTDI{sub vol} to an effective dose.

  20. Patient doses from CT examinations in Turkey

    PubMed Central

    Ataç, Gökçe Kaan; Parmaksız, Aydın; İnal, Tolga; Bulur, Emine; Bulgurlu, Figen; Öncü, Tolga; Gündoğdu, Sadi

    2015-01-01

    PURPOSE We aimed to establish the first diagnostic reference levels (DRLs) for computed tomography (CT) examinations in adult and pediatric patients in Turkey and compare these with international DRLs. METHODS CT performance information and examination parameters (for head, chest, high-resolution CT of the chest [HRCT-chest], abdominal, and pelvic protocols) from 1607 hospitals were collected via a survey. Dose length products and effective doses for standard patient sizes were calculated from the reported volume CT dose index (CTDIvol). RESULTS The median number of protocols reported from the 167 responding hospitals (10% response rate) was 102 across five different age groups. Third quartile CTDIvol values for adult pelvic and all pediatric body protocols were higher than the European Commission standards but were comparable to studies conducted in other countries. CONCLUSION The radiation dose indicators for adult patients were similar to those reported in the literature, except for those associated with head protocols. CT protocol optimization is necessary for adult head and pediatric chest, HRCT-chest, abdominal, and pelvic protocols. The findings from this study are recommended for use as national DRLs in Turkey. PMID:26133189

  1. Ultralow dose computed tomography attenuation correction for pediatric PET CT using adaptive statistical iterative reconstruction

    SciTech Connect

    Brady, Samuel L.; Shulkin, Barry L.

    2015-02-15

    Purpose: To develop ultralow dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultralow doses (10–35 mA s). CT quantitation: noise, low-contrast resolution, and CT numbers for 11 tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% volume computed tomography dose index (0.39/3.64; mGy) from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUV{sub bw}) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative dose reduction and noise control. Results: CT numbers were constant to within 10% from the nondose reduced CTAC image for 90% dose reduction. No change in SUV{sub bw}, background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols was found down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62% and 86% (3.2/8.3–0.9/6.2). Noise magnitude in dose-reduced patient images increased but was not statistically different from predose-reduced patient images. Conclusions: Using ASiR allowed for aggressive reduction in CT dose with no change in PET reconstructed images while maintaining sufficient image quality for colocalization of hybrid CT anatomy and PET radioisotope uptake.

  2. GMctdospp: Description and validation of a CT dose calculation system

    SciTech Connect

    Schmidt, Ralph Wulff, Jörg; Zink, Klemens

    2015-07-15

    Purpose: To develop a Monte Carlo (MC)-based computed tomography (CT) dose estimation method with a graphical user interface with options to define almost arbitrary simulation scenarios, to make calculations sufficiently fast for comfortable handling, and to make the software free of charge for general availability to the scientific community. Methods: A framework called GMctdospp was developed to calculate phantom and patient doses with the MC method based on the EGSnrc system. A CT scanner was modeled for testing and was adapted to half-value layer, beam-shaping filter, z-profile, and tube-current modulation (TCM). To validate the implemented variance reduction techniques, depth-dose and cross-profile calculations of a static beam were compared against DOSXYZnrc/EGSnrc. Measurements for beam energies of 80 and 120 kVp at several positions of a CT dose-index (CTDI) standard phantom were compared against calculations of the created CT model. Finally, the efficiency of the adapted code was benchmarked against EGSnrc defaults. Results: The CT scanner could be modeled accurately. The developed TCM scheme was confirmed by the dose measurement. A comparison of calculations to DOSXYZnrc showed no systematic differences. Measurements in a CTDI phantom could be reproduced within 2% average, with a maximal difference of about 6%. Efficiency improvements of about six orders of magnitude were observed for larger organ structures of a chest-examination protocol in a voxelized phantom. In these cases, simulations took 25 s to achieve a statistical uncertainty of ∼0.5%. Conclusions: A fast dose-calculation system for phantoms and patients in a CT examination was developed, successfully validated, and benchmarked. Influences of scan protocols, protection method, and other issues can be easily examined with the developed framework.

  3. Radiation dose reduction using 100-kVp and a sinogram-affirmed iterative reconstruction algorithm in adolescent head CT: Impact on grey-white matter contrast and image noise.

    PubMed

    Nagayama, Yasunori; Nakaura, Takeshi; Tsuji, Akinori; Urata, Joji; Furusawa, Mitsuhiro; Yuki, Hideaki; Hirarta, Kenichiro; Kidoh, Masafumi; Oda, Seitaro; Utsunomiya, Daisuke; Yamashita, Yasuyuki

    2017-07-01

    To retrospectively evaluate the image quality and radiation dose of 100-kVp scans with sinogram-affirmed iterative reconstruction (IR) for unenhanced head CT in adolescents. Sixty-nine patients aged 12-17 years underwent head CT under 120- (n = 34) or 100-kVp (n = 35) protocols. The 120-kVp images were reconstructed with filtered back-projection (FBP), 100-kVp images with FBP (100-kVp-F) and sinogram-affirmed IR (100-kVp-S). We compared the effective dose (ED), grey-white matter (GM-WM) contrast, image noise, and contrast-to-noise ratio (CNR) between protocols in supratentorial (ST) and posterior fossa (PS). We also assessed GM-WM contrast, image noise, sharpness, artifacts, and overall image quality on a four-point scale. ED was 46% lower with 100- than 120-kVp (p < 0.001). GM-WM contrast was higher, and image noise was lower, on 100-kVp-S than 120-kVp at ST (p < 0.001). CNR of 100-kVp-S was higher than of 120-kVp (p < 0.001). GM-WM contrast of 100-kVp-S was subjectively rated as better than of 120-kVp (p < 0.001). There were no significant differences in the other criteria between 100-kVp-S and 120-kVp (p = 0.072-0.966). The 100-kVp with sinogram-affirmed IR facilitated dramatic radiation reduction and better GM-WM contrast without increasing image noise in adolescent head CT. • 100-kVp head CT provides 46% radiation dose reduction compared with 120-kVp. • 100-kVp scanning improves subjective and objective GM-WM contrast. • Sinogram-affirmed IR decreases head CT image noise, especially in supratentorial region. • 100-kVp protocol with sinogram-affirmed IR is suited for adolescent head CT.

  4. Adaptive sampling of CT data for myocardial blood flow estimation from dose-reduced dynamic CT

    NASA Astrophysics Data System (ADS)

    Modgil, Dimple; Bindschadler, Michael D.; Alessio, Adam M.; La Rivière, Patrick J.

    2015-03-01

    Quantification of myocardial blood flow (MBF) can aid in the diagnosis and treatment of coronary artery disease (CAD). However, there are no widely accepted clinical methods for estimating MBF. Dynamic CT holds the promise of providing a quick and easy method to measure MBF quantitatively, however the need for repeated scans has raised concerns about the potential for high radiation dose. In our previous work, we explored techniques to reduce the patient dose by either uniformly reducing the tube current or by uniformly reducing the number of temporal frames in the dynamic CT sequence. These dose reduction techniques result in very noisy data, which can give rise to large errors in MBF estimation. In this work, we seek to investigate whether nonuniformly varying the tube current or sampling intervals can yield more accurate MBF estimates. Specifically, we try to minimize the dose and obtain the most accurate MBF estimate through addressing the following questions: when in the time attenuation curve (TAC) should the CT data be collected and at what tube current(s). We hypothesize that increasing the sampling rate and/or tube current during the time frames when the myocardial CT number is most sensitive to the flow rate, while reducing them elsewhere, can achieve better estimation accuracy for the same dose. We perform simulations of contrast agent kinetics and CT acquisitions to evaluate the relative MBF estimation performance of several clinically viable adaptive acquisition methods. We found that adaptive temporal and tube current sequences can be performed that impart an effective dose of about 5 mSv and allow for reductions in MBF estimation RMSE on the order of 11% compared to uniform acquisition sequences with comparable or higher radiation doses.

  5. [Dose optimization in CT examination of children].

    PubMed

    Hojreh, A; Prosch, H

    2012-10-01

    Problems arise due to the increased clinical use of computed tomography (CT) and the high radiosensitivity of children. The ALARA concept (as low as reasonably achievable) prevails in pediatric radiology. Justified indications and full utilization of available dose optimization methods. Medical physicists and the manufacturers should support pediatric radiology in the implementation of the ALARA concept. The referring physicians and radiology staff should be integrated into training programs. Sufficient diagnostic image quality is paramount and not the pretty images.

  6. Dose reduction in pediatric computed tomography with automated exposure control.

    PubMed

    Alibek, Sedat; Brand, Martin; Suess, Christoph; Wuest, Wolfgang; Uder, Michael; Greess, Holger

    2011-06-01

    Since the introduction of computed tomographic (CT) imaging in the 1970s, the number of examinations has increased steadily. CT imaging is an essential part of routine workup in diagnostic radiology. The great advantage of multidetector computed tomography is the acquisition of a large amount of data in a short time period, thus speeding up diagnostic procedures. To protect patients from unnecessary radiation exposure, different approaches have been developed. In this study, the efficacy of automated exposure control (AEC) software in multidetector CT imaging with a focus on dose reduction in pediatric examinations was assessed. Between August 2004 and September 2005, a total of 71 children (40 male, 31 female; age range, 2-13 years; mean age, 7.2 years) were examined using a multisource CT scanner. Three different regions (chest, upper abdomen, and pelvis) were examined. Overall image quality was assessed with a subjective scale (1 = excellent, 2 = diagnostic, 3 = nondiagnostic). For all examinations, AEC was used. From the scanner's patient protocol, dose-length product, volume CT dose index, and tube current-time product were calculated for each examination. With AEC, a mean dose reduction of 30.6% was calculated. Images were rated as excellent (n = 39) or diagnostic (n = 32). Nondiagnostic image quality was not seen. Dose-length product and volume CT dose index were reduced by 30.4% and 29.5%, respectively. Overall, a mean dose reduction of 30.1% of the effective dose (5.8 ± 3.1 vs 8.4 ± 4.6 mSv) was achieved (P < .001). With AEC software, a mean dose reduction of 30% without any loss in diagnostic image quality is possible. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  7. [Indications for low-dose CT in the emergency setting].

    PubMed

    Poletti, Pierre-Alexandre; Andereggen, Elisabeth; Rutschmann, Olivier; de Perrot, Thomas; Caviezel, Alessandro; Platon, Alexandra

    2009-08-19

    CT delivers a large dose of radiation, especially in abdominal imaging. Recently, a low-dose abdominal CT protocol (low-dose CT) has been set-up in our institution. "Low-dose CT" is almost equivalent to a single standard abdominal radiograph in term of dose of radiation (about one sixth of those delivered by a standard CT). "Low-dose CT" is now used routinely in our emergency service in two main indications: patients with a suspicion of renal colic and those with right lower quadrant pain. It is obtained without intravenous contrast media. Oral contrast is given to patients with suspicion of appendicitis. "Low-dose CT" is used in the frame of well defined clinical algorithms, and does only replace standard CT when it can reach a comparable diagnostic quality.

  8. CT pulmonary angiography using a reduced volume of high-concentration iodinated contrast medium and multiphasic injection to achieve dose reduction.

    PubMed

    Goble, E W; Abdulkarim, J A

    2014-01-01

    To evaluate whether a reduced volume of a higher-concentration iodinated contrast medium delivered with a multiphasic injection could be used in computed tomography pulmonary angiography (CTPA) to achieve a reduction in dose without adversely affecting image quality. The CTPA images were retrospectively evaluated of 69 patients who received 100 ml of 300 mg iodine/ml ioversol, injected at constant rate of 5 ml/s and 70 patients who received 75 ml of 350 mg iodine/ml ioversol contrast medium delivered using a multiphasic injection protocol (starting at 5 ml/s and reducing exponentially). The degree of opacification in the proximal pulmonary arteries was measured in Hounsfield units. The groups did not differ in terms of age, sex distribution, or weight. The mean iodine dose was lower in the 75 ml of 350 mg iodine/ml group (26.25 versus 29.5 g, p < 0.0001). Mean opacification did not differ significantly between the 75 ml of 350 mg iodine/ml and 100 ml of 300 mg iodine/ml groups in the main pulmonary artery (365 versus 331, p = 0.055) although it was significantly higher in the 75 ml group in the right (352 versus 315, p = 0.024) and left pulmonary arteries (347 versus 312, p = 0.028). Opacification correlated positively with age and negatively with weight (p < 0.001) and when these effects had been accounted for, the differences in opacification were not statistically significant in the main (p = 0.23), right (p = 0.11), or left pulmonary arteries (p = 0.13). The number of suboptimally opacified studies (opacification of less than 250 HU in main pulmonary artery) did not differ between the groups (12 versus 13, p = 0.83). A reduction in iodine dose can be achieved without adversely affecting pulmonary arterial enhancement in CTPA by administering a smaller volume of high-concentration contrast medium using a multiphasic injection protocol. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method.

    PubMed

    Larson, David B

    2014-10-01

    The principle of ALARA (dose as low as reasonably achievable) calls for dose optimization rather than dose reduction, per se. Optimization of CT radiation dose is accomplished by producing images of acceptable diagnostic image quality using the lowest dose method available. Because it is image quality that constrains the dose, CT dose optimization is primarily a problem of image quality rather than radiation dose. Therefore, the primary focus in CT radiation dose optimization should be on image quality. However, no reliable direct measure of image quality has been developed for routine clinical practice. Until such measures become available, size-specific dose estimates (SSDE) can be used as a reasonable image-quality estimate. The SSDE method of radiation dose optimization for CT abdomen and pelvis consists of plotting SSDE for a sample of examinations as a function of patient size, establishing an SSDE threshold curve based on radiologists' assessment of image quality, and modifying protocols to consistently produce doses that are slightly above the threshold SSDE curve. Challenges in operationalizing CT radiation dose optimization include data gathering and monitoring, managing the complexities of the numerous protocols, scanners and operators, and understanding the relationship of the automated tube current modulation (ATCM) parameters to image quality. Because CT manufacturers currently maintain their ATCM algorithms as secret for proprietary reasons, prospective modeling of SSDE for patient populations is not possible without reverse engineering the ATCM algorithm and, hence, optimization by this method requires a trial-and-error approach.

  10. Radiation dose in 320-slice multidetector cardiac CT: a single center experience of evolving dose minimization.

    PubMed

    Tung, Matthew K; Cameron, James D; Casan, Joshua M; Crossett, Marcus; Troupis, John M; Meredith, Ian T; Seneviratne, Sujith K

    2013-01-01

    Minimization of radiation exposure remains an important subject that occurs in parallel with advances in scanner technology. We report our experience of evolving radiation dose and its determinants after the introduction of 320-multidetector row cardiac CT within a single tertiary cardiology referral service. Four cohorts of consecutive patients (total 525 scans), who underwent cardiac CT at defined time points as early as 2008, are described. These include a cohort just after scanner installation, after 2 upgrades of the operating system, and after introduction of an adaptive iterative image reconstruction algorithm. The proportions of nondiagnostic coronary artery segments and studies with nondiagnostic segments were compared between cohorts. Significant reductions were observed in median radiation doses in all cohorts compared with the initial cohort (P < .001). Median dose-length product fell from 944 mGy · cm (interquartile range [IQR], 567.3-1426.5 mGy · cm) to 156 mGy · cm (IQR, 99.2-265.0 mGy · cm). Although the proportion of prospectively triggered scans has increased, reductions in radiation dose have occurred independently of distribution of scan formats. In multiple regression that combined all groups, determinants of dose-length product were tube output, the number of cardiac cycles scanned, tube voltage, scan length, scan format, body mass index, phase width, and heart rate (adjusted R(2) = 0.85, P < .001). The proportion of nondiagnostic coronary artery segments was slightly increased in group 4 (2.9%; P < .01). While maintaining diagnostic quality in 320-multidetector row cardiac CT, the radiation dose has decreased substantially because of a combination of dose-reduction protocols and technical improvements. Continued minimization of radiation dose will increase the potential for cardiac CT to expand as a cardiac imaging modality. Copyright © 2013 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  11. Dose assessment according to changes in algorithm in cardiac CT

    NASA Astrophysics Data System (ADS)

    Jang, H. C.; Cho, J. H.; Lee, H. K.; Hong, I. S.; Cho, M. S.; Park, C. S.; Lee, S. Y.; Dong, K. R.; Goo, E. H.; Chung, W. K.; Ryu, Y. H.; Lim, C. S.

    2012-06-01

    The principal objective of this study was to determine the effects of the application of the adaptive statistical iterative reconstruction (ASIR) technique in combination with another two factors (body mass index (BMI) and tube potential) on radiation dose in cardiac computed tomography (CT). For quantitative analysis, regions of interest were positioned on the central region of the great coronary artery, the right coronary artery, and the left anterior descending artery, after which the means and standard deviations of measured CT numbers were obtained. For qualitative analysis, images taken from the major coronary arteries (right coronary, left anterior descending, and left circumflex) were graded on a scale of 1-5, with 5 indicating the best image quality. Effective dose, which was calculated by multiplying the value of the dose length product by a standard conversion factor of 0.017 for the chest, was employed as a measure of radiation exposure dose. In cardiac CT in patients with BMI of less than 25 kg/m2, the use of 40% ASIR in combination with a low tube potential of 100 kVp resulted in a significant reduction in the radiation dose without compromising diagnostic quality. Additionally, the combination of the 120 kVp protocol and the application of 40% ASIR application for patients with BMI higher than 25 kg/m2 yielded similar results.

  12. A study evaluating the dependence of the patient dose on the CT dose change in a SPECT/CT scan

    NASA Astrophysics Data System (ADS)

    Kim, Woo-Hyun; Kim, Ho-Sung; Dong, Kyung-Rae; Chung, Woon-Kwan; Cho, Jae-Hwan; Shin, Jae-Woo

    2012-07-01

    This study assessed ways of reducing the patient dose by examining the dependence of the patient dose on the CT (computed tomography) dose in a SPECT (single-photon emission computed tomography)/CT scan. To measure the patient dose, we used Precedence 16 SPECT/CT along with a phantom for the CT dose measurement (CT dose phantom kit for adult's head and body, Model 76-414-4150), a 100-mm ionization chamber (CT Ion Chamber) and an X-ray detector (Victoreen Model 4000M+). In addition, the patient dose was evaluated under conditions similar to those for an actual examination using an ImPACT (imaging performance assessment of CT scanners) dosimetry calculator in the Monte Carlo simulation method. The experimental method involved the use of a CT dose phantom to measure the patient dose under different CT conditions (kVp and mAs) to determine the CTDI (CT dose index) under each condition. An ImPACT dosimetry calculator was also used to measure CTDIw (CT dose index water ), CTDIv (CT dose index volume ), DLP (dose-length product), and effective dose. According to the patient dose measurements using the CT dose phantom, the CTDI showed an approximately 54 fold difference between when the maximum (140 kVp and 250 mAs) and the minimum dose (90 kVp and 25 mAs) was used. The CTDI showed a 4.2 fold difference between the conditions (120 kVp and 200 mAs) used mainly in a common CT scan and the conditions (120 kVp and 50 mAs) used mainly in a SPECT/CT scan. According to the measurement results using the dosimetry calculator, the effective dose showed an approximately 35 fold difference between the conditions for the maximum and the minimum doses, as in the case with the CT dose phantom. The effective dose showed a 4.1 fold difference between the conditions used mainly in a common CT scan and those used mainly in a SPECT/CT scan. This study examined the patient dose by reducing the CT dose in a SPECT/CT scan. As various examinations can be conducted due to the development of

  13. Adaptively Tuned Iterative Low Dose CT Image Denoising

    PubMed Central

    Hashemi, SayedMasoud; Paul, Narinder S.; Beheshti, Soosan; Cobbold, Richard S. C.

    2015-01-01

    Improving image quality is a critical objective in low dose computed tomography (CT) imaging and is the primary focus of CT image denoising. State-of-the-art CT denoising algorithms are mainly based on iterative minimization of an objective function, in which the performance is controlled by regularization parameters. To achieve the best results, these should be chosen carefully. However, the parameter selection is typically performed in an ad hoc manner, which can cause the algorithms to converge slowly or become trapped in a local minimum. To overcome these issues a noise confidence region evaluation (NCRE) method is used, which evaluates the denoising residuals iteratively and compares their statistics with those produced by additive noise. It then updates the parameters at the end of each iteration to achieve a better match to the noise statistics. By combining NCRE with the fundamentals of block matching and 3D filtering (BM3D) approach, a new iterative CT image denoising method is proposed. It is shown that this new denoising method improves the BM3D performance in terms of both the mean square error and a structural similarity index. Moreover, simulations and patient results show that this method preserves the clinically important details of low dose CT images together with a substantial noise reduction. PMID:26089972

  14. Adaptively Tuned Iterative Low Dose CT Image Denoising.

    PubMed

    Hashemi, SayedMasoud; Paul, Narinder S; Beheshti, Soosan; Cobbold, Richard S C

    2015-01-01

    Improving image quality is a critical objective in low dose computed tomography (CT) imaging and is the primary focus of CT image denoising. State-of-the-art CT denoising algorithms are mainly based on iterative minimization of an objective function, in which the performance is controlled by regularization parameters. To achieve the best results, these should be chosen carefully. However, the parameter selection is typically performed in an ad hoc manner, which can cause the algorithms to converge slowly or become trapped in a local minimum. To overcome these issues a noise confidence region evaluation (NCRE) method is used, which evaluates the denoising residuals iteratively and compares their statistics with those produced by additive noise. It then updates the parameters at the end of each iteration to achieve a better match to the noise statistics. By combining NCRE with the fundamentals of block matching and 3D filtering (BM3D) approach, a new iterative CT image denoising method is proposed. It is shown that this new denoising method improves the BM3D performance in terms of both the mean square error and a structural similarity index. Moreover, simulations and patient results show that this method preserves the clinically important details of low dose CT images together with a substantial noise reduction.

  15. Patient-specific dose estimation for pediatric chest CT

    SciTech Connect

    Li Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.

    2008-12-15

    any other patient in the same size/protocol group who undergoes the chest scan. In summary, this work reported the first assessment of dose variations across pediatric CT patients in the same size/protocol group due to the variability of patient anatomy and body habitus and provided a previously unavailable method for patient-specific organ dose estimation, which will help in assessing patient risk and optimizing dose reduction strategies, including the development of scan protocols.

  16. Dose reduction in spiral CT coronary angiography with dual source equipment. Part II. Dose surplus due to slope-up and slope-down of prospective tube current modulation in a phantom model.

    PubMed

    Martini, C; Palumbo, A; Maffei, E; Rossi, A; Rengo, M; Malagò, R; Dijkshoorn, M; Weustink, A; Mollet, N; Krestin, G; Cademartiri, F

    2010-02-01

    This study was undertaken to estimate surplus radiation dose in retrospectively electrocardiography (ECG)-gated dual-source computed tomography coronary angiography (DSCT-CA) due to the slope-up and slope-down of the tube current using prospectively ECG-triggered tube modulation. We used an anthropomorphic phantom with an ECG-gated retrospective protocol and a DSCT scanner (Definition, Siemens). We used four tube current modulation algorithms: narrow pulsing window, with tube current reduction to 20% (A) and 4% (B) of peak current; and wide pulsing window, with tube current reduction to 20% (C) and 4% (D). Each algorithm was applied at five heart rates (HR=45, 60, 75, 90 and 120 bpm) with adaptive pitch values (0.2-0.5). Data sets were reconstructed in 5% increments from 0-95% of the R-R interval. Noise was measured at each R-R step in order to identify low noise (100% dose), medium noise (slope-up/down) and high noise (4/20% dose). Width of the transition window (slope-up/slope-down from 4/20% to 100% dose) was calculated. The surplus dose due to slope-up/slope-down was calculated. Surplus dose was 19% (A), 34% (B), 14% (C) and 21% (D). The transition window lasted 10%+10% (slope-up + down) for HR <75 bpm and all HR in C (except for 120 bpm; 25%+15%), 15%+15% for HR >90 bpm (A). For C and D, instead, the slope-up increased with progressively higher HR (10%-25% of the R-R interval, except for 90 bpm, 10%), whereas the slope-down remained constant at 5% (except for 120 bpm; 10%). The adaptive ECG-pulsing windows produced an increment of the surplus dose with increasing HR. The transition window was a constant source of surplus radiation dose in the range of 14%-34%.

  17. Implementation of interior micro-CT on a carbon nanotube dynamic micro-CT scanner for lower radiation dose

    NASA Astrophysics Data System (ADS)

    Gong, Hao; Lu, Jianping; Zhou, Otto; Cao, Guohua

    2015-03-01

    Micro-CT is a high-resolution volumetric imaging tool that provides imaging evaluations for many preclinical applications. However, the relatively high cumulative radiation dose from micro-CT scans could lead to detrimental influence on the experimental outcomes or even the damages of specimens. Interior micro-computed tomography (micro- CT) produces exact tomographic images of an interior region-of-interest (ROI) embedded within an object from truncated projection data. It holds promises for many biomedical applications with significantly reduced radiation doses. Here, we present our first implementation of an interior micro-CT system using a carbon nanotube (CNT) field-emission microfocus x-ray source. The system has two modes - interior micro-CT mode and global micro-CT mode, which is realized with a detachable x-ray beam collimator at the source side. The interior mode has an effective field-of-view (FOV) of about 10mm in diameter, while for the global mode the FOV is about 40mm in diameter. We acquired CT data in these two modes from a mouse-sized phantom, and compared the reconstructed image qualities and the associated radiation exposures. Interior ROI reconstruction was achieved by using our in-house developed reconstruction algorithm. Overall, interior micro-CT demonstrated comparable image quality to the conventional global micro-CT. Radiation doses measured by an ion chamber show that interior micro-CT yielded significant dose reduction (up to 83%).

  18. Optimal dose reduction in computed tomography methodologies predicted from real-time dosimetry

    NASA Astrophysics Data System (ADS)

    Tien, Christopher Jason

    Over the past two decades, computed tomography (CT) has become an increasingly common and useful medical imaging technique. CT is a noninvasive imaging modality with three-dimensional volumetric viewing abilities, all in sub-millimeter resolution. Recent national scrutiny on radiation dose from medical exams has spearheaded an initiative to reduce dose in CT. This work concentrates on dose reduction of individual exams through two recently-innovated dose reduction techniques: organ dose modulation (ODM) and tube current modulation (TCM). ODM and TCM tailor the phase and amplitude of x-ray current, respectively, used by the CT scanner during the scan. These techniques are unique because they can be used to achieve patient dose reduction without any appreciable loss in image quality. This work details the development of the tools and methods featuring real-time dosimetry which were used to provide pioneering measurements of ODM or TCM in dose reduction for CT.

  19. Ultra low-dose CT attenuation correction in PET SPM

    NASA Astrophysics Data System (ADS)

    Wang, Shyh-Jen; Yang, Bang-Hung; Tsai, Chia-Jung; Yang, Ching-Ching; Lee, Jason J. S.; Wu, Tung-Hsin

    2010-07-01

    The use of CT images for attenuation correction (CTAC) allows significantly shorter scanning time and a high quality noise-free attenuation map compared with conventional germanium-68 transmission scan because at least 10 4 times greater of photon flux would be generated from a CT scan under standard operating condition. However, this CTAC technique would potentially introduce more radiation risk to the patients owing to the higher radiation exposure from CT scan. Statistic parameters mapping (SPM) is a prominent technique in nuclear medicine community for the analysis of brain imaging data. The purpose of this study is to assess the feasibility of low-dose CT (LDCT) and ultra low-dose CT (UDCT) in PET SPM applications. The study was divided into two parts. The first part was to evaluate of tracer uptake distribution pattern and quantity analysis by using the striatal phantom to initially assess the feasibility of AC for clinical purpose. The second part was to examine the group SPM analysis using the Hoffman brain phantom. The phantom study is to simulate the human brain and to reduce the experimental uncertainty of real subjects. The initial studies show that the results of PET SPM analysis have no significant differences between LDCT and UDCT comparing to the current used default CTAC. Moreover, the dose of the LDCT is lower than that of the default CT by a factor of 9, and UDCT can even yield a 42 times dose reduction. We have demonstrated the SPM results while using LDCT and UDCT for PET AC is comparable to those using default CT setting, suggesting their feasibility in PET SPM applications. In addition, the necessity of UDCT in PET SPM studies to avoid excess radiation dose is also evident since most of the subjects involved are non-cancer patients or children and some normal subjects are even served as a comparison group in the experiment. It is our belief that additional attempts to decrease the radiation dose would be valuable, especially for children and

  20. 20 percent lower lung cancer mortality with low-dose CT vs chest X-ray

    Cancer.gov

    Scientists have found a 20 percent reduction in deaths from lung cancer among current or former heavy smokers who were screened with low-dose helical computed tomography (CT) versus those screened by chest X-ray.

  1. The effective dose result of 18F-FDG PET-CT paediatric patients

    NASA Astrophysics Data System (ADS)

    Hussin, D.; Said, M. A.; Ali, N. S.; Tajuddin, A. A.; Zainon, R.

    2017-05-01

    Paediatric patient received high exposure from both CT and PET examination. Automatic Exposure Control (AEC) is important in CT dose reduction. This study aimed to compare the effective dose obtained from PET-CT scanner with and without the use of AEC function. In this study, 68 patients underwent PET-CT examination without the use of AEC function, while 25 patients used the AEC function during the examination. Patients involved in this study were between 2 to 15 years old with varies of malignancies and epilepsy diseases. The effective dose obtained from PET and CT examinations was calculated based on recommendation from International Commission on Radiological Protection (ICRP) Publication 106 and ICRP publication 102. The outcome of this study shows that the radiation dose was reduced up to 20% with the use of AEC function. The mean average of effective dose result obtained from PET and CT examinations without the use of AEC and AEC function were found to be as 6.67 mSv, 6.77 mSv, 6.03mSv and 4.96 mSv respectively. Where total effective dose result of PET-CT with non-AEC and AEC were found to be 13.44 mSv and 10.99 mSv respectively. Conclusion of this study is, the installation of AEC function in PET-CT machine does play important role in CT dose reduction especially for paediatric patient.

  2. Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

    PubMed

    McCollough, Cynthia H; Chen, Guang Hong; Kalender, Willi; Leng, Shuai; Samei, Ehsan; Taguchi, Katsuyuki; Wang, Ge; Yu, Lifeng; Pettigrew, Roderic I

    2012-08-01

    This Special Report presents the consensus of the Summit on Management of Radiation Dose in Computed Tomography (CT) (held in February 2011), which brought together participants from academia, clinical practice, industry, and regulatory and funding agencies to identify the steps required to reduce the effective dose from routine CT examinations to less than 1 mSv. The most promising technologies and methods discussed at the summit include innovations and developments in x-ray sources; detectors; and image reconstruction, noise reduction, and postprocessing algorithms. Access to raw projection data and standard data sets for algorithm validation and optimization is a clear need, as is the need for new, clinically relevant metrics of image quality and diagnostic performance. Current commercially available techniques such as automatic exposure control, optimization of tube potential, beam-shaping filters, and dynamic z-axis collimators are important, and education to successfully implement these methods routinely is critically needed. Other methods that are just becoming widely available, such as iterative reconstruction, noise reduction, and postprocessing algorithms, will also have an important role. Together, these existing techniques can reduce dose by a factor of two to four. Technical advances that show considerable promise for additional dose reduction but are several years or more from commercial availability include compressed sensing, volume of interest and interior tomography techniques, and photon-counting detectors. This report offers a strategic roadmap for the CT user and research and manufacturer communities toward routinely achieving effective doses of less than 1 mSv, which is well below the average annual dose from naturally occurring sources of radiation.

  3. Achieving Routine Submillisievert CT Scanning: Report from the Summit on Management of Radiation Dose in CT

    PubMed Central

    Chen, Guang Hong; Kalender, Willi; Leng, Shuai; Samei, Ehsan; Taguchi, Katsuyuki; Wang, Ge; Yu, Lifeng; Pettigrew, Roderic I.

    2012-01-01

    This Special Report presents the consensus of the Summit on Management of Radiation Dose in Computed Tomography (CT) (held in February 2011), which brought together participants from academia, clinical practice, industry, and regulatory and funding agencies to identify the steps required to reduce the effective dose from routine CT examinations to less than 1 mSv. The most promising technologies and methods discussed at the summit include innovations and developments in x-ray sources; detectors; and image reconstruction, noise reduction, and postprocessing algorithms. Access to raw projection data and standard data sets for algorithm validation and optimization is a clear need, as is the need for new, clinically relevant metrics of image quality and diagnostic performance. Current commercially available techniques such as automatic exposure control, optimization of tube potential, beam-shaping filters, and dynamic z-axis collimators are important, and education to successfully implement these methods routinely is critically needed. Other methods that are just becoming widely available, such as iterative reconstruction, noise reduction, and postprocessing algorithms, will also have an important role. Together, these existing techniques can reduce dose by a factor of two to four. Technical advances that show considerable promise for additional dose reduction but are several years or more from commercial availability include compressed sensing, volume of interest and interior tomography techniques, and photon-counting detectors. This report offers a strategic roadmap for the CT user and research and manufacturer communities toward routinely achieving effective doses of less than 1 mSv, which is well below the average annual dose from naturally occurring sources of radiation. © RSNA, 2012 PMID:22692035

  4. Patient doses from hybrid SPECT-CT procedures.

    PubMed

    Avramova-Cholakova, S; Dimcheva, M; Petrova, E; Garcheva, M; Dimitrova, M; Palashev, Y; Vassileva, J

    2015-07-01

    The aim of this work is to estimate patient doses from hybrid single-photon emission computed tomography (SPECT) and computed tomography (CT) procedures. The study involved all four SPECT-CT systems in Bulgaria. Effective dose was estimated for about 100 patients per system. Ten types of examinations were considered, representing all diagnostic procedures performed in the SPECT-CT systems. Effective doses from the SPECT component were calculated applying the ICRP 53 and ICRP 80 conversion coefficients. Computed tomography dose index and dose length product were retrospectively obtained from the archives of the systems, and effective doses from the CT component were calculated with CT-Expo software. Parallel estimation of CT component contribution with the National Radiological Protection Board (NRPB) conversion coefficients was performed where applicable. Large variations were found in the current practice of SPECT-CT imaging. Optimisation actions and diagnostic reference levels were proposed.

  5. Cone beam CT for dental and maxillofacial imaging: dose matters.

    PubMed

    Pauwels, Ruben

    2015-07-01

    The widespread use of cone-beam CT (CBCT) in dentistry has led to increasing concern regarding justification and optimisation of CBCT exposures. When used as a substitute to multidetector CT (MDCT), CBCT can lead to significant dose reduction; however, low-dose protocols of current-generation MDCTs show that there is an overlap between CBCT and MDCT doses. More importantly, although the 3D information provided by CBCT can often lead to improved diagnosis and treatment compared with 2D radiographs, a routine or excessive use of CBCT would lead to a substantial increase of the collective patient dose. The potential use of CBCT for paediatric patients (e.g. developmental disorders, trauma and orthodontic treatment planning) further increases concern regarding its proper application. This paper provides an overview of justification and optimisation issues in dental and maxillofacial CBCT. The radiation dose in CBCT will be briefly reviewed. The European Commission's Evidence Based Guidelines prepared by the SEDENTEXCT Project Consortium will be summarised, and (in)appropriate use of CBCT will be illustrated for various dental applications.

  6. CT dose minimization using personalized protocol optimization and aggressive bowtie

    NASA Astrophysics Data System (ADS)

    Wang, Hui; Yin, Zhye; Jin, Yannan; Wu, Mingye; Yao, Yangyang; Tao, Kun; Kalra, Mannudeep K.; De Man, Bruno

    2016-03-01

    In this study, we propose to use patient-specific x-ray fluence control to reduce the radiation dose to sensitive organs while still achieving the desired image quality (IQ) in the region of interest (ROI). The mA modulation profile is optimized view by view, based on the sensitive organs and the ROI, which are obtained from an ultra-low-dose volumetric CT scout scan [1]. We use a clinical chest CT scan to demonstrate the feasibility of the proposed concept: the breast region is selected as the sensitive organ region while the cardiac region is selected as IQ ROI. Two groups of simulations are performed based on the clinical CT dataset: (1) a constant mA scan adjusted based on the patient attenuation (120 kVp, 300 mA), which serves as baseline; (2) an optimized scan with aggressive bowtie and ROI centering combined with patient-specific mA modulation. The results shows that the combination of the aggressive bowtie and the optimized mA modulation can result in 40% dose reduction in the breast region, while the IQ in the cardiac region is maintained. More generally, this paper demonstrates the general concept of using a 3D scout scan for optimal scan planning.

  7. Dose performance of a 64-channel dual-source CT scanner.

    PubMed

    McCollough, Cynthia H; Primak, Andrew N; Saba, Osama; Bruder, Herbert; Stierstorfer, Karl; Raupach, Rainer; Suess, Christoph; Schmidt, Bernhard; Ohnesorge, Bernd M; Flohr, Thomas G

    2007-06-01

    To prospectively compare the dose performance of a 64-channel multi-detector row computed tomographic (CT) scanner and a 64-channel dual-source CT scanner from the same manufacturer. To minimize dose in the cardiac (dual-source) mode, the evaluated dual-source CT system uses a cardiac beam-shaping filter, three-dimensional adaptive noise reduction, heart rate-dependent pitch, and electrocardiographically based modulation of the tube current. Weighted CT dose index per 100 mAs was measured for the head, body, and cardiac beam-shaping filters. Kerma-length product was measured in the spiral cardiac mode at four pitch values and three electrocardiographic modulation temporal windows. Noise was measured in an anthropomorphic phantom. Data were compared with data from a 64-channel multi-detector row CT scanner. For the multi-detector row and dual-source CT systems, respectively, weighted CT dose index per 100 mAs was 14.2 and 12.2 mGy (head CT), 6.8 and 6.4 mGy (body CT), and 6.8 and 5.3 mGy (cardiac CT). In the spiral cardiac mode (no electrocardiographically based tube current modulation, 0.2 pitch), equivalent noise occurred at volume CT dose index values of 23.7 and 35.0 mGy (coronary artery calcium CT) and 58.9 and 61.2 mGy (coronary CT angiography) for multi-detector row CT and dual-source CT, respectively. The use of heart rate-dependent pitch values reduced volume CT dose index to 46.2 mGy (0.265 pitch), 34.0 mGy (0.36 pitch), and 26.6 mGy (0.46 pitch) compared with 61.2 mGy for 0.2 pitch. The use of electrocardiographically based tube current-modulation and temporal windows of 110, 210, and 310 msec further reduced volume CT dose index to 9.1-25.1 mGy, dependent on the heart rate. For electrocardiographically gated coronary CT angiography, image noise equivalent to that of multi-detector row CT can be achieved with dual-source CT at doses comparable to or up to a factor of two lower than the doses at multi-detector row CT, depending on heart rate of the patient

  8. Assessment of bilateral filter on 1/2-dose chest-pelvis CT views.

    PubMed

    Al-Hinnawi, Abdel Razzak; Daear, Mohammed; Huwaijah, Said

    2013-07-01

    A bilateral filter (BF) is a non-linear filter that has been proved to de-noise images without overrunning edges. Multi-slice computerized tomography (CT) may employ a BF to participate in dose reduction. This paper quantifies the role of the BF in achieving this objective on 1/2-dose CT. Two sets of CT images are acquired for the chest-pelvis at two different radiation doses. The BF was applied on the 1/2-dose CT images by use of various window sizes. Each time, a set of values of the BF range was fixed while the BF domain was modified. The goal was to observe the behavior of the BF on 1/2-dose CT images in comparison with full-dose CT images. The comparison was carried out by use of four co-occurrence matrix descriptors. Additionally, the peak signal-to-noise ratio (PSNR) and the mean square error (MSE) were reported. The study was applied to the sagittal, coronal, and axial CT views. The results showed that the impact of applying a BF varies among different CT views. The BF can retrieve only part of the signal being lost due to reduction of the radiation dose by one half. Yet, the BF improves the appearance of the 1/2-dose chest-pelvis CT examination. Thus, the BF can contribute to a 50% dose reduction. A procedure for employing the BF on CT machines is proposed. The results also showed that texture descriptors are similar to the PSNR and MSE in providing quantities for assessing medical image quality.

  9. Metal artifact reduction of CT scans to improve PET/CT.

    PubMed

    van der Vos, Charlotte S; Arens, Anne Ij; Hamill, Jim; Hofmann, Christian; Panin, Vladimir Y; Meeuwis, Antoi Pw; Visser, Eric P; de Geus-Oei, Lioe-Fee

    2017-05-10

    In recent years different metal artifact reduction (MAR) methods have been developed for computed tomography (CT). These methods have only recently been introduced for positron emission tomography/computed tomography (PET/CT) even though they could be beneficial for interpretation, segmentation and quantification of the PET/CT images. In this study, phantom and patient scans were analyzed visually and quantitatively to measure the effect on PET images of iterative metal artifact reduction (iMAR) of CT data. Methods The phantom consisted of two types of hip prostheses in a solution of (18)F-flurodeoxyglucose ((18)F-FDG) and water. (18)F-FDG PET/CT scans of 14 patients with metal implants (either dental implants, hip prostheses, shoulder prostheses or pedicle screws) and (68)Ga-labeled prostate-specific membrane antigen ((68)Ga-PSMA) PET/CT scans of 7 patients with hip prostheses were scored by two experienced nuclear medicine physicians to analyze clinical relevance. For all patients a lesion was located in the field of view of the metal implant. Phantom and patients were scanned in an mCT PET/CT scanner (Siemens Healthcare). The standard low-dose CTs were processed with the iMAR algorithm. The PET data were reconstructed using attenuation correction provided by both standard CT and iMAR-processed CT. Results For the phantom scans cold artifacts were visible on the PET image. There was a 30% deficit in (18)F-FDG concentration, which was restored by iMAR processing, indicating that metal artifacts on CT images induce quantification errors in PET data. The iMAR algorithm was useful for most patients. When iMAR was used the confidence in interpretation increased or stayed the same, with an average improvement of 28±20% (scored on a scale of 0-100% confidence). The standardized uptake value (SUV) increase or decrease depended on the type of metal artifact. The mean difference in absolute values of SUVmean of the lesions was 3.5±3.3%. Conclusion The iMAR algorithm

  10. Low-dose CT screening for lung cancer with automatic exposure control: phantom study.

    PubMed

    Gomi, Shiho; Muramatsu, Yoshihisa; Tsukagoshi, Shinsuke; Suzuki, Masahiro; Kakinuma, Ryutaro; Tsuchiya, Ryosuke; Moriyama, Noriyuki

    2008-07-01

    We conducted a study to determine optimal scan conditions for automatic exposure control (AEC) in computed tomography (CT) of low-dose chest screening in order to provide consistent image quality without increasing the collective dose. Using a chest CT phantom, we set CT-AEC scan conditions with a dose-reduction wedge (DR-Wedge) to the same radiation dose as those for low-tube current, fixed-scan conditions. Image quality was evaluated with the use of the standard deviation of the CT number, contrast-noise ratios (CNR), and receiver-operating characteristic (ROC) analysis. At the same radiation dose, in the scan conditions using CT-AEC with the DR-Wedge, the SD of the CT number of each slice position was stable. The CNR values were higher at the lung apex and lung base under CT-AEC with the DR-Wedge than under standard scan conditions (p < 0.0002). In addition, ROC analysis of blind evaluation by four radiologists and three technologists showed that the image quality was improved for the lung apex (p < 0.009), tracheal bifurcation (p < 0.038), and lung base (p < 0.022) in the scan conditions using CT-AEC with the DR-Wedge. We achieved improvement of image quality without increasing the collective dose by using CT-AEC with the DR-Wedge under low-dose scan conditions.

  11. Impact of Dose-Modified Protocols on Radiation Doses in Patients Undergoing CT Examinations following Image-Guided Catheter Placement.

    PubMed

    Andrabi, Yasir; Saadeh, Thomas S; Uppot, Raul N; Arellano, Ronald S; Sahani, Dushyant V

    2015-09-01

    To investigate the impact of dose-modified (DM) scan protocols on decreasing radiation exposure from computed tomography (CT) scans obtained following image-guided catheter procedures. In this retrospective analysis, between December 2012 and June 2014, 192 patients (mean age, 60.7 y; 102 men) who underwent abdomen/pelvis CT examinations for catheter placement follow-up were included. The standard-dose (SD) baseline CT parameters included tube potential of 120 kVp, tube current of 75-550 mA, and noise index (NI) of 18-22. Weight-based scan parameters applied for follow-up CT were based on two reconstruction algorithms: filtered back projection (FBP; 120 kVp, 75-350 mA, NI = 30) and iterative reconstruction technique (IRT; 100/120 kVp, 75-250/350 mA, NI = 35). Two readers reviewed image quality (IQ) of follow-up and baseline CT examinations for 22 randomly sampled patients. Radiation doses were retrieved by dose monitoring software. Compared with baseline, DM follow-up CT protocols enabled substantial (62.4%) dose reductions (mean CT dose indexes: 4.1 mGy at follow-up, 10.9 mGy at baseline; P < .0001). Doses were significantly lower for IRT follow-up CT examinations compared with FBP (mean CT dose indexes: IRT, 3.6 mGy; FBP, 4.6 mGy; P < .05). In 47 patients with more than one follow-up CT examination (mean, 3.1 examinations per patient; range, 2-6), the observed cumulative radiation dose (CRD) was 42.1% lower than the expected CRD (observed, 1,437.9 mGy·cm; expected, 2,483.6 mGy·cm; P < .0001). Subjective IQ scores were acceptable for follow-up CT examinations (follow-up, 3.6; baseline, 4; P < .05). DM CT examinations enable substantial dose reduction (62.4%) for each follow-up examination compared with SD baseline scans, without any IQ concerns. Use of IRT decreases dose by an additional 22%. The CRD is lowered by 42% in patients undergoing multiple DM follow-up CT examinations. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  12. Poster — Thur Eve — 06: Dose assessment of cone beam CT imaging protocols as part of SPECT/CT examinations

    SciTech Connect

    Tonkopi, E; Ross, AA

    2014-08-15

    Purpose: To assess radiation dose from the cone beam CT (CBCT) component of SPECT/CT studies and to compare with other CT examinations performed in our institution. Methods: We used an anthropomorphic chest phantom and the 6 cc ion chamber to measure entrance breast dose for several CBCT and diagnostic CT acquisition protocols. The CBCT effective dose was calculated with ImPACT software; the CT effective dose was evaluated from the DLP value and conversion factor, dependent on the anatomic region. The RADAR medical procedure radiation dose calculator was used to assess the nuclear medicine component of exam dose. Results: The entrance dose to the breast measured with the anthropomorphic phantom was 0.48 mGy and 9.41 mGy for cardiac and chest CBCT scans; and 4.59 mGy for diagnostic thoracic CT. The effective doses were 0.2 mSv, 3.2 mSv and 2.8 mSv respectively. For a small patient represented by the anthropomorphic phantom, the dose from the diagnostic CT was lower than from the CBCT scan, as a result of the exposure reduction options available on modern CT scanners. The CBCT protocols used the same fixed scanning techniques. The diagnostic CT dose based on the patient data was 35% higher than the phantom dose. For most SPECT/CT studies the dose from the CBCT component was comparable with the dose from the radiopharmaceutical. Conclusions: The patient radiation dose from the cone beam CT scan can be higher than that from a diagnostic CT and should be taken into consideration in evaluating total SPECT/CT patient dose.

  13. Accuracy of low dose CT in the diagnosis of appendicitis in childhood and comparison with USG and standard dose CT.

    PubMed

    Yi, Dae Yong; Lee, Kyung Hoon; Park, Sung Bin; Kim, Jee Taek; Lee, Na Mi; Kim, Hyery; Yun, Sin Weon; Chae, Soo Ahn; Lim, In Seok

    2017-04-23

    Computed tomography should be performed after careful consideration due to radiation hazard, which is why interest in low dose CT has increased recently in acute appendicitis. Previous studies have been performed in adult and adolescents populations, but no studies have reported on the efficacy of using low-dose CT in children younger than 10 years. Patients (n=475) younger than 10 years who were examined for acute appendicitis were recruited. Subjects were divided into three groups according to the examinations performed: low-dose CT, ultrasonography, and standard-dose CT. Subjects were categorized according to age and body mass index (BMI). Low-dose CT was a contributive tool in diagnosing appendicitis, and it was an adequate method, when compared with ultrasonography and standard-dose CT in terms of sensitivity (95.5% vs. 95.0% and 94.5%, p=0.794), specificity (94.9% vs. 80.0% and 98.8%, p=0.024), positive-predictive value (96.4% vs. 92.7% and 97.2%, p=0.019), and negative-predictive value (93.7% vs. 85.7% and 91.3%, p=0.890). Low-dose CT accurately diagnosed patients with a perforated appendix. Acute appendicitis was effectively diagnosed using low-dose CT in both early and middle childhood. BMI did not influence the accuracy of detecting acute appendicitis on low-dose CT. Low-dose CT is effective and accurate for diagnosing acute appendicitis in childhood, as well as in adolescents and young adults. Additionally, low-dose CT was relatively accurate, irrespective of age or BMI, for detecting acute appendicitis. Therefore, low-dose CT is recommended for assessing children with suspected acute appendicitis. Copyright © 2017. Published by Elsevier Editora Ltda.

  14. Effects of High Volume MOSFET Usage on Dosimetry in Pediatric CT, Pediatric Lens of the Eye Dose Reduction Using Siemens Care kV, & Designing Quality Assurance of a Cesium Calibration Source

    NASA Astrophysics Data System (ADS)

    Smith, Aaron Kenneth

    taking the standard deviation of a large regions of interest in both the lung and the soft tissue of the chest to measure the noise. Results: The proof of concept experiment found that the main cable of the MOSET, not the ends closest to the reading tip, is the most attenuating part of the cable. The proof of concept also found that increasing the number of MOSFET layers to 1, 2, 3, and 4 layers decreased the dose to the center of the phantom by 17.92, 28.04, 39.98, 42.49% respectively. Increasing the percent of the block phantom covered to 10, 30, and 50% coverage decreased the dose to the center of the phantom by 17.92, 17.80, and 18.17% respectively. Project 2: Pediatric Lens of the Eye Dose Reduction Using Siemens Care kV: Purpose: The Siemens Care kV is a software that recommends a tube potential (kV) setting for CT scans based on the thickness of the anatomy being scanned in order to reduce dose on a patient to patient basis. Pediatric cranial scans at Duke do not use this software nor do they use tube current modulation. Dose to the lens of the eye in pediatric patients can lead to lens opacity later in life [10]. The goal of this project was to determine if Care kV can be used in pediatric cranial scans to reduce the dose to the lens of the eye while maintaining adequate image quality. Materials and Methods: A Siemens SOMATOM Force CT scanner performing a routine cranial scan protocol was used in concert with two Atom Dosimetry Phantoms (1-year-old and 5-year-old) and MOSFET dosimeters to determine the effect changing the reference tube potential of the Care kV software would have on dose and image quality (measured with CNR). The settings used with Care kV were off, and semi reference tube potential 120, 110, and 100 kV. Results: Dose to the lens of the eye was reduced for the 1-year old phantom by 9.601, 17.572, and 19.724% by using Care kV with tube potential set to 120, 110 and 100 kV respectively. Dose to the lens of the eye was reduced for the 5-year old

  15. Principles of CT: radiation dose and image quality.

    PubMed

    Goldman, Lee W

    2007-12-01

    This article discusses CT radiation dose, the measurement of CT dose, and CT image quality. The most commonly used dose descriptor is CT dose index, which represents the dose to a location (e.g., depth) in a scanned volume from a complete series of slices. A weighted average of the CT dose index measured at the center and periphery of dose phantoms provides a convenient single-number estimate of patient dose for a procedure, and this value (or a related indicator that includes the scanned length) is often displayed on the operator's console. CT image quality, as in most imaging, is described in terms of contrast, spatial resolution, image noise, and artifacts. A strength of CT is its ability to visualize structures of low contrast in a subject, a task that is limited primarily by noise and is therefore closely associated with radiation dose: The higher the dose contributing to the image, the less apparent is image noise and the easier it is to perceive low-contrast structures. Spatial resolution is ultimately limited by sampling, but both image noise and resolution are strongly affected by the reconstruction filter. As a result, diagnostically acceptable image quality at acceptable doses of radiation requires appropriately designed clinical protocols, including appropriate kilovolt peaks, amperages, slice thicknesses, and reconstruction filters.

  16. Dose reduction in paediatric MDCT: general principles.

    PubMed

    Paterson, A; Frush, D P

    2007-06-01

    The number of multi-detector array computed tomography (MDCT) examinations performed per annum continues to increase in both the adult and paediatric populations. Estimates from 2003 suggested that CT contributed 17% of a radiology department's workload, yet was responsible for up to 75% of the collective population dose from medical radiation. The effective doses for some CT examinations today overlap with those argued to have an increased risk of cancer. This is especially pertinent for paediatric CT, as children are more radiosensitive than adults (and girls more radiosensitive than boys). In addition, children have a longer life ahead of them, in which radiation induced cancers may become manifest. Radiologists must be aware of these facts and practise the ALARA (as low as is reasonably achievable) principle, when it comes to deciding CT protocols and parameters.

  17. Experimental benchmarking of a Monte Carlo dose simulation code for pediatric CT

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Samei, Ehsan; Yoshizumi, Terry; Colsher, James G.; Jones, Robert P.; Frush, Donald P.

    2007-03-01

    In recent years, there has been a desire to reduce CT radiation dose to children because of their susceptibility and prolonged risk for cancer induction. Concerns arise, however, as to the impact of dose reduction on image quality and thus potentially on diagnostic accuracy. To study the dose and image quality relationship, we are developing a simulation code to calculate organ dose in pediatric CT patients. To benchmark this code, a cylindrical phantom was built to represent a pediatric torso, which allows measurements of dose distributions from its center to its periphery. Dose distributions for axial CT scans were measured on a 64-slice multidetector CT (MDCT) scanner (GE Healthcare, Chalfont St. Giles, UK). The same measurements were simulated using a Monte Carlo code (PENELOPE, Universitat de Barcelona) with the applicable CT geometry including bowtie filter. The deviations between simulated and measured dose values were generally within 5%. To our knowledge, this work is one of the first attempts to compare measured radial dose distributions on a cylindrical phantom with Monte Carlo simulated results. It provides a simple and effective method for benchmarking organ dose simulation codes and demonstrates the potential of Monte Carlo simulation for investigating the relationship between dose and image quality for pediatric CT patients.

  18. Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic.

    PubMed

    Poletti, Pierre-Alexandre; Platon, Alexandra; Rutschmann, Olivier T; Schmidlin, Franz R; Iselin, Christophe E; Becker, Christoph D

    2007-04-01

    The purpose of our study was to compare a low-dose abdominal CT protocol, delivering a dose of radiation close to the dose delivered by abdominal radiography, with standard-dose unenhanced CT in patients with suspected renal colic. One hundred twenty-five patients (87 men, 38 women; mean age, 45 years) who were admitted with suspected renal colic underwent both abdominal low-dose CT (30 mAs) and standard-dose CT (180 mAs). Low-dose CT and standard-dose CT were independently reviewed, in a delayed fashion, by two radiologists for the characterization of renal and ureteral calculi (location, size) and for indirect signs of renal colic (renal enlargement, pyeloureteral dilatation, periureteral or renal stranding). Results reported for low-dose CT, with regard to the patients' body mass indexes (BMIs), were compared with those obtained with standard-dose CT (reference standard). The presence of non-urinary tract-related disorders was also assessed. Informed consent was obtained from all patients. In patients with a BMI < 30, low-dose CT achieved 96% sensitivity and 100% specificity for the detection of indirect signs of renal colic and a sensitivity of 95% and a specificity of 97% for detecting ureteral calculi. In patients with a BMI < 30, low-dose CT was 86% sensitive for detecting ureteral calculi < 3 mm and 100% sensitive for detecting calculi > 3 mm. Low-dose CT was 100% sensitive and specific for depicting non-urinary tract-related disorders (n = 6). Low-dose CT achieves sensitivities and specificities close to those of standard-dose CT in assessing the diagnosis of renal colic, depicting ureteral calculi > 3 mm in patients with a BMI < 30, and correctly identifying alternative diagnoses.

  19. Quantifying the potential for dose reduction with visual grading regression

    PubMed Central

    Smedby, Ö; Fredrikson, M; De Geer, J; Borgen, L; Sandborg, M

    2013-01-01

    Objectives To propose a method to study the effect of exposure settings on image quality and to estimate the potential for dose reduction when introducing dose-reducing measures. Methods Using the framework of visual grading regression (VGR), a log(mAs) term is included in the ordinal logistic regression equation, so that the effect of reducing the dose can be quantitatively related to the effect of adding post-processing. In the ordinal logistic regression, patient and observer identity are treated as random effects using generalised linear latent and mixed models. The potential dose reduction is then estimated from the regression coefficients. The method was applied in a single-image study of coronary CT angiography (CTA) to evaluate two-dimensional (2D) adaptive filters, and in an image-pair study of abdominal CT to evaluate 2D and three-dimensional (3D) adaptive filters. Results For five image quality criteria in coronary CTA, dose reductions of 16–26% were predicted when adding 2D filtering. Using five image quality criteria for abdominal CT, it was estimated that 2D filtering permits doses were reduced by 32–41%, and 3D filtering by 42–51%. Conclusions VGR including a log(mAs) term can be used for predictions of potential dose reduction that may be useful for guiding researchers in designing subsequent studies evaluating diagnostic value. With appropriate statistical analysis, it is possible to obtain direct numerical estimates of the dose-reducing potential of novel acquisition, reconstruction or post-processing techniques. PMID:22723511

  20. Quantifying the potential for dose reduction with visual grading regression.

    PubMed

    Smedby, O; Fredrikson, M; De Geer, J; Borgen, L; Sandborg, M

    2013-01-01

    To propose a method to study the effect of exposure settings on image quality and to estimate the potential for dose reduction when introducing dose-reducing measures. Using the framework of visual grading regression (VGR), a log(mAs) term is included in the ordinal logistic regression equation, so that the effect of reducing the dose can be quantitatively related to the effect of adding post-processing. In the ordinal logistic regression, patient and observer identity are treated as random effects using generalised linear latent and mixed models. The potential dose reduction is then estimated from the regression coefficients. The method was applied in a single-image study of coronary CT angiography (CTA) to evaluate two-dimensional (2D) adaptive filters, and in an image-pair study of abdominal CT to evaluate 2D and three-dimensional (3D) adaptive filters. For five image quality criteria in coronary CTA, dose reductions of 16-26% were predicted when adding 2D filtering. Using five image quality criteria for abdominal CT, it was estimated that 2D filtering permits doses were reduced by 32-41%, and 3D filtering by 42-51%. VGR including a log(mAs) term can be used for predictions of potential dose reduction that may be useful for guiding researchers in designing subsequent studies evaluating diagnostic value. With appropriate statistical analysis, it is possible to obtain direct numerical estimates of the dose-reducing potential of novel acquisition, reconstruction or post-processing techniques.

  1. Quantifying the potential for dose reduction with visual grading regression.

    PubMed

    Smedby, O; Fredrikson, M; De Geer, J; Borgen, L; Sandborg, M

    2013-01-01

    Objectives To propose a method to study the effect of exposure settings on image quality and to estimate the potential for dose reduction when introducing dose-reducing measures. Methods Using the framework of visual grading regression (VGR), a log(mAs) term is included in the ordinal logistic regression equation, so that the effect of reducing the dose can be quantitatively related to the effect of adding post-processing. In the ordinal logistic regression, patient and observer identity are treated as random effects using generalised linear latent and mixed models. The potential dose reduction is then estimated from the regression coefficients. The method was applied in a single-image study of coronary CT angiography (CTA) to evaluate two-dimensional (2D) adaptive filters, and in an image-pair study of abdominal CT to evaluate 2D and three-dimensional (3D) adaptive filters. Results For five image quality criteria in coronary CTA, dose reductions of 16-26% were predicted when adding 2D filtering. Using five image quality criteria for abdominal CT, it was estimated that 2D filtering permits doses were reduced by 32-41%, and 3D filtering by 42-51%. Conclusions VGR including a log(mAs) term can be used for predictions of potential dose reduction that may be useful for guiding researchers in designing subsequent studies evaluating diagnostic value. With appropriate statistical analysis, it is possible to obtain direct numerical estimates of the dose-reducing potential of novel acquisition, reconstruction or post-processing techniques.

  2. [Phantom Study on Dose Reduction Using Iterative Reconstruction in Low-dose Computed Tomography for Lung Cancer Screening].

    PubMed

    Minehiro, Kaori; Takata, Tadanori; Hayashi, Hiroyuki; Sakuda, Keita; Nunome, Haruka; Kawashima, Hiroko; Sanada, Shigeru

    2015-12-01

    We investigated dose reduction ability of an iterative reconstruction technology for low-dose computed tomography (CT) for lung cancer screening. The Sinogram Affirmed Iterative Reconstruction (SAFIRE) provided in a multi slice CT system, Somatom Definition Flash (Siemens Healthcare) was used. An anthropomorphic chest phantom (N-1, Kyoto Kagaku) was scanned at volume CT dose index (CTDIvol) of 0.50-11.86 mGy with 120 kV. For noise (standard deviation) and contrast-to-noise ratio (CNR) measurements, CTP486 and CTP515 modules in the Catphan (The Phantom Laboratory) were scanned. Radiological technologists were participated in the perceptual comparison. SAFIRE reduced the SD values by approximately 50% compared with filter back projection (FBP). The estimated dose reduction rates by SAFIRE determined from the perceptual comparison was approximately 23%, while 75% dose reduction rate was expected from the SD value reduction of 50%.

  3. Model-based iterative reconstruction in ultra-low-dose pediatric chest CT: comparison with adaptive statistical iterative reconstruction.

    PubMed

    Kim, Hae Jin; Yoo, So-Young; Jeon, Tae Yeon; Kim, Ji Hye

    2016-01-01

    To evaluate image quality and dose reduction of ultra-low-dose pediatric chest CT reconstructed with model-based iterative reconstruction (MBIR), as compared with adaptive statistical iterative reconstruction (ASIR). Fifty-seven patients (mean age 14 years, M:F=31:26) who underwent ultra-low-dose chest CT reconstructed with both MBIR and ASIR were enrolled in the study. The subjective and objective image qualities of both reconstruction techniques were assessed by 3 radiologists, and compared using statistical analysis. We also evaluated radiation dose of ultra-low-dose chest CT as well as degree of dose reduction in comparison to the prior CT (either standard dose or reduced dose protocol) available in 36 patients. The image quality of MBIR was superior to ASIR both subjectively and objectively. While MBIR showed preserved diagnostic acceptability in 100%, ASIR showed 92% at mean 0.31 mSv (range, 0.13-0.57 mSv) ultra-low-dose CT. In the 36 patients who underwent the prior CT, mean decrease in size-specific dose estimate (SSDE) and dose length product (DLP) at ultra-low-dose CT was 88% (range, 34% - 98%) and 86% (range,42% - 99%), respectively. MBIR significantly improves image quality, as compared to ASIR. Furthermore, MBIR facilitates diagnostically acceptable ultra-low-dose chest CT with nearly 90% less radiation. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Patient-specific dose estimation for pediatric chest CT

    PubMed Central

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.

    2008-01-01

    -specific organ dose for any other patient in the same size/protocol group who undergoes the chest scan. In summary, this work reported the first assessment of dose variations across pediatric CT patients in the same size/protocol group due to the variability of patient anatomy and body habitus and provided a previously unavailable method for patient-specific organ dose estimation, which will help in assessing patient risk and optimizing dose reduction strategies, including the development of scan protocols. PMID:19175138

  5. Dose reconstruction for real-time patient-specific dose estimation in CT

    SciTech Connect

    De Man, Bruno Yin, Zhye; Wu, Mingye; FitzGerald, Paul; Kalra, Mannudeep

    2015-05-15

    Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization. Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors’ specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth. Results: The authors’ results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm. Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.

  6. CT Radiation Dose Optimization and Estimation: an Update for Radiologists

    PubMed Central

    2012-01-01

    In keeping with the increasing utilization of CT examinations, the greater concern about radiation hazards from examinations has been addressed. In this regard, CT radiation dose optimization has been given a great deal of attention by radiologists, referring physicians, technologists, and physicists. Dose-saving strategies are continuously evolving in terms of imaging techniques as well as dose management. Consequently, regular updates of this issue are necessary especially for radiologists who play a pivotal role in this activity. This review article will provide an update on how we can optimize CT dose in order to maximize the benefit-to-risk ratio of this clinically useful diagnostic imaging method. PMID:22247630

  7. CT radiation dose optimization and estimation: an update for radiologists.

    PubMed

    Goo, Hyun Woo

    2012-01-01

    In keeping with the increasing utilization of CT examinations, the greater concern about radiation hazards from examinations has been addressed. In this regard, CT radiation dose optimization has been given a great deal of attention by radiologists, referring physicians, technologists, and physicists. Dose-saving strategies are continuously evolving in terms of imaging techniques as well as dose management. Consequently, regular updates of this issue are necessary especially for radiologists who play a pivotal role in this activity. This review article will provide an update on how we can optimize CT dose in order to maximize the benefit-to-risk ratio of this clinically useful diagnostic imaging method.

  8. Practical strategies to reduce pediatric CT radiation dose.

    PubMed

    Nelson, Thomas R

    2014-03-01

    The objective of this article is to provide a brief review of CT scanning radiation sensitivity in children and explain CT scan parameters that affect radiation dose. We discuss key factors influencing radiation dose and study quality and how these factors can be used to optimize scan protocols with the goal of reducing pediatric CT radiation dose without compromising diagnostic quality. Finally, we provide some practical tips for reducing radiation doses to children. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  9. Dose reduction in dynamic CT stress myocardial perfusion imaging: comparison of 80-kV/370-mAs and 100-kV/300-mAs protocols.

    PubMed

    Fujita, Makiko; Kitagawa, Kakuya; Ito, Tatsuro; Shiraishi, Yasuyuki; Kurobe, Yusuke; Nagata, Motonori; Ishida, Masaki; Sakuma, Hajime

    2014-03-01

    To determine the effect of reduced 80-kV tube voltage with increased 370-mAs tube current on radiation dose, image quality and estimated myocardial blood flow (MBF) of dynamic CT stress myocardial perfusion imaging (CTP) in patients with a normal body mass index (BMI) compared with a 100-kV and 300-mAs protocol. Thirty patients with a normal BMI (<25 kg/m(2)) with known or suspected coronary artery disease underwent adenosine-stress dual-source dynamic CTP. Patients were randomised to 80-kV/370-mAs (n = 15) or 100-kV/300-mAs (n = 15) imaging. Maximal enhancement and noise of the left ventricular (LV) cavity, contrast-to-noise ratio (CNR) and MBF of the two groups were compared. Imaging with 80-kV/370-mAs instead of 100-kV/300-mAs was associated with 40% lower radiation dose (mean dose-length product, 359 ± 66 vs 628 ± 112 mGy[Symbol: see text]cm; P < 0.001 ) with no significant difference in CNR (34.5 ± 13.4 vs 33.5 ± 10.4; P = 0.81) or MBF in non-ischaemic myocardium (0.95 ± 0.20 vs 0.99 ± 0.25 ml/min/g; P = 0.66). Studies obtained using 80-kV/370-mAs were associated with 30.9% higher maximal enhancement (804 ± 204 vs 614 ± 115 HU; P < 0.005), and 31.2% greater noise (22.7 ± 3.5 vs 17.4 ± 2.6; P < 0.001). Dynamic CTP using 80-kV/370-mA instead of 100-kV/300-mAs allowed 40% dose reduction without compromising image quality or MBF. Tube voltage of 80-kV should be considered for individuals with a normal BMI. • CT stress perfusion imaging (CTP) is increasingly used to assess myocardial function. • Dynamic CTP is feasible at 80-kV in patients with normal BMI. • An 80-kV/370-mAs protocol allows 40% dose reduction compared with 100-kV/300-mAs. • Contrast-to-noise ratio and myocardial blood flow of the two protocols were comparable.

  10. A Simple Low-dose X-ray CT Simulation from High-dose Scan.

    PubMed

    Zeng, Dong; Huang, Jing; Bian, Zhaoying; Niu, Shanzhou; Zhang, Hua; Feng, Qianjin; Liang, Zhengrong; Ma, Jianhua

    2015-10-01

    Low-dose X-ray computed tomography (CT) simulation from high-dose scan is required in optimizing radiation dose to patients. In this study, we propose a simple low-dose CT simulation strategy in sinogram domain using the raw data from high-dose scan. Specially, a relationship between the incident fluxes of low- and high- dose scans is first determined according to the repeated projection measurements and analysis. Second, the incident flux level of the simulated low-dose scan is generated by properly scaling the incident flux level of high-dose scan via the determined relationship in the first step. Third, the low-dose CT transmission data by energy integrating detection is simulated by adding a statistically independent Poisson noise distribution plus a statistically independent Gaussian noise distribution. Finally, a filtered back-projection (FBP) algorithm is implemented to reconstruct the resultant low-dose CT images. The present low-dose simulation strategy is verified on the simulations and real scans by comparing it with the existing low-dose CT simulation tool. Experimental results demonstrated that the present low-dose CT simulation strategy can generate accurate low-dose CT sinogram data from high-dose scan in terms of qualitative and quantitative measurements.

  11. Realistic simulation of reduced-dose CT with noise modeling and sinogram synthesis using DICOM CT images

    SciTech Connect

    Won Kim, Chang; Kim, Jong Hyo

    2014-01-15

    Purpose: Reducing the patient dose while maintaining the diagnostic image quality during CT exams is the subject of a growing number of studies, in which simulations of reduced-dose CT with patient data have been used as an effective technique when exploring the potential of various dose reduction techniques. Difficulties in accessing raw sinogram data, however, have restricted the use of this technique to a limited number of institutions. Here, we present a novel reduced-dose CT simulation technique which provides realistic low-dose images without the requirement of raw sinogram data. Methods: Two key characteristics of CT systems, the noise equivalent quanta (NEQ) and the algorithmic modulation transfer function (MTF), were measured for various combinations of object attenuation and tube currents by analyzing the noise power spectrum (NPS) of CT images obtained with a set of phantoms. Those measurements were used to develop a comprehensive CT noise model covering the reduced x-ray photon flux, object attenuation, system noise, and bow-tie filter, which was then employed to generate a simulated noise sinogram for the reduced-dose condition with the use of a synthetic sinogram generated from a reference CT image. The simulated noise sinogram was filtered with the algorithmic MTF and back-projected to create a noise CT image, which was then added to the reference CT image, finally providing a simulated reduced-dose CT image. The simulation performance was evaluated in terms of the degree of NPS similarity, the noise magnitude, the bow-tie filter effect, and the streak noise pattern at photon starvation sites with the set of phantom images. Results: The simulation results showed good agreement with actual low-dose CT images in terms of their visual appearance and in a quantitative evaluation test. The magnitude and shape of the NPS curves of the simulated low-dose images agreed well with those of real low-dose images, showing discrepancies of less than +/−3.2% in

  12. Realistic simulation of reduced-dose CT with noise modeling and sinogram synthesis using DICOM CT images

    SciTech Connect

    Won Kim, Chang; Kim, Jong Hyo

    2014-01-15

    Purpose: Reducing the patient dose while maintaining the diagnostic image quality during CT exams is the subject of a growing number of studies, in which simulations of reduced-dose CT with patient data have been used as an effective technique when exploring the potential of various dose reduction techniques. Difficulties in accessing raw sinogram data, however, have restricted the use of this technique to a limited number of institutions. Here, we present a novel reduced-dose CT simulation technique which provides realistic low-dose images without the requirement of raw sinogram data. Methods: Two key characteristics of CT systems, the noise equivalent quanta (NEQ) and the algorithmic modulation transfer function (MTF), were measured for various combinations of object attenuation and tube currents by analyzing the noise power spectrum (NPS) of CT images obtained with a set of phantoms. Those measurements were used to develop a comprehensive CT noise model covering the reduced x-ray photon flux, object attenuation, system noise, and bow-tie filter, which was then employed to generate a simulated noise sinogram for the reduced-dose condition with the use of a synthetic sinogram generated from a reference CT image. The simulated noise sinogram was filtered with the algorithmic MTF and back-projected to create a noise CT image, which was then added to the reference CT image, finally providing a simulated reduced-dose CT image. The simulation performance was evaluated in terms of the degree of NPS similarity, the noise magnitude, the bow-tie filter effect, and the streak noise pattern at photon starvation sites with the set of phantom images. Results: The simulation results showed good agreement with actual low-dose CT images in terms of their visual appearance and in a quantitative evaluation test. The magnitude and shape of the NPS curves of the simulated low-dose images agreed well with those of real low-dose images, showing discrepancies of less than +/−3.2% in

  13. Adaptive mean filtering for noise reduction in CT polymer gel dosimetry

    SciTech Connect

    Hilts, Michelle; Jirasek, Andrew

    2008-01-15

    X-ray computed tomography (CT) as a method of extracting 3D dose information from irradiated polymer gel dosimeters is showing potential as a practical means to implement gel dosimetry in a radiation therapy clinic. However, the response of CT contrast to dose is weak and noise reduction is critical in order to achieve adequate dose resolutions with this method. Phantom design and CT imaging technique have both been shown to decrease image noise. In addition, image postprocessing using noise reduction filtering techniques have been proposed. This work evaluates in detail the use of the adaptive mean filter for reducing noise in CT gel dosimetry. Filter performance is systematically tested using both synthetic patterns mimicking a range of clinical dose distribution features as well as actual clinical dose distributions. Both low and high signal-to-noise ratio (SNR) situations are examined. For all cases, the effects of filter kernel size and the number of iterations are investigated. Results indicate that adaptive mean filtering is a highly effective tool for noise reduction CT gel dosimetry. The optimum filtering strategy depends on characteristics of the dose distributions and image noise level. For low noise images (SNR {approx}20), the filtered results are excellent and use of adaptive mean filtering is recommended as a standard processing tool. For high noise images (SNR {approx}5) adaptive mean filtering can also produce excellent results, but filtering must be approached with more caution as spatial and dose distortions of the original dose distribution can occur.

  14. Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality.

    PubMed

    Habib Geryes, Bouchra; Calmon, Raphael; Khraiche, Diala; Boddaert, Nathalie; Bonnet, Damien; Raimondi, Francesca

    2016-07-01

    To assess the impact of different protocols on radiation dose and image quality for paediatric coronary computed tomography (cCT). From January-2012 to June-2014, 140 children who underwent cCT on a 64-slice scanner were included. Two consecutive changes in imaging protocols were performed: 1) the use of adaptive statistical iterative reconstruction (ASIR); 2) the optimization of acquisition parameters. Effective dose (ED) was calculated by conversion of the dose-length product. Image quality was assessed as excellent, good or with significant artefacts. Patients were divided in three age groups: 0-4, 5-7 and 8-18 years. The use of ASIR combined to the adjustment of scan settings allowed a reduction in the median ED of 58 %, 82 % and 85 % in 0-4, 5-7 and 8-18 years group, respectively (7.3 ± 1.4 vs 3.1 ± 0.7 mSv, 5.5 ± 1.6 vs 1 ± 1.9 mSv and 5.3 ± 5.0 vs 0.8 ± 2.0 mSv, all p < 0,05). Prospective protocol was used in 51 % of children. The reduction in radiation dose was not associated with reduction in diagnostic image quality as assessed by the frequency of coronary segments with excellent or good image quality (88 %). cCT can be obtained at very low radiation doses in children using ASIR, and prospective acquisition with optimized imaging parameters. • Using ASIR allows 25 % to 41 % reduction in the ED. • Prospective protocol is used up to 51 % of children after premedication. • Low dose is possible using ASIR and optimized prospective paediatric cCT.

  15. Organ doses to adult patients for chest CT

    SciTech Connect

    Huda, Walter; Sterzik, Alexander; Tipnis, Sameer; Schoepf, U. Joseph

    2010-02-15

    Purpose: The goal of this study was to estimate organ doses for chest CT examinations using volume computed tomography dose index (CTDI{sub vol}) data as well as accounting for patient weight. Methods: A CT dosimetry spreadsheet (ImPACT CT patient dosimetry calculator) was used to compute organ doses for a 70 kg patient undergoing chest CT examinations, as well as volume computed tomography dose index (CTDI{sub vol}) in a body CT dosimetry phantom at the same CT technique factors. Ratios of organ dose to CTDI{sub vol} (f{sub organ}) were generated as a function of anatomical location in the chest for the breasts, lungs, stomach, red bone marrow, liver, thyroid, liver, and thymus. Values of f{sub organ} were obtained for x-ray tube voltages ranging from 80 to 140 kV for 1, 4, 16, and 64 slice CT scanners from two vendors. For constant CT techniques, we computed ratios of dose in water phantoms of differing diameter. By modeling patients of different weights as equivalent water cylinders of different diameters, we generated factors that permit the estimation of the organ doses in patients weighing between 50 and 100 kg who undergo chest CT examinations relative to the corresponding organ doses received by a 70 kg adult. Results: For a 32 cm long CT scan encompassing the complete lungs, values of f{sub organ} ranged from 1.7 (thymus) to 0.3 (stomach). Organs that are directly in the x-ray beam, and are completely irradiated, generally had f{sub organ} values well above 1 (i.e., breast, lung, heart, and thymus). Organs that are not completely irradiated in a total chest CT scan generally had f{sub organ} values that are less than 1 (e.g., red bone marrow, liver, and stomach). Increasing the x-ray tube voltage from 80 to 140 kV resulted in modest increases in f{sub organ} for the heart (9%) and thymus (8%), but resulted in larger increases for the breast (19%) and red bone marrow (21%). Adult patient chests have been modeled by water cylinders with diameters between

  16. Radiation dose of CT coronary angiography in clinical practice: objective evaluation of strategies for dose optimization.

    PubMed

    Yerramasu, Ajay; Venuraju, Shreenidhi; Atwal, Satvir; Goodman, Dennis; Lipkin, David; Lahiri, Avijit

    2012-07-01

    CT coronary angiography (CTCA) is an evolving modality for the diagnosis of coronary artery disease. Radiation burden associated with CTCA has been a major concern in the wider application of this technique. It is important to reduce the radiation dose without compromising the image quality. To estimate the radiation dose of CTCA in clinical practice and evaluate the effect of dose-saving algorithms on radiation dose and image quality. Effective radiation dose was measured from the dose-length product in 616 consecutive patients (mean age 58 ± 12 years; 70% males) who underwent clinically indicated CTCA at our institution over 1 year. Image quality was assessed subjectively using a 4-point scale and objectively by measuring the signal- and contrast-to-noise ratios in the coronary arteries. Multivariate linear regression analysis was used to identify factors independently associated with radiation dose. Mean effective radiation dose of CTCA was 6.6 ± 3.3 mSv. Radiation dose was significantly reduced by dose saving algorithms such as 100 kV imaging (-47%; 95% CI, -44% to -50%), prospective gating (-35%; 95% CI, -29% to -40%) and ECG controlled tube current modulation (-23%; 95% CI, -9% to -34%). None of the dose saving algorithms were associated with a significant reduction in mean image quality or the frequency of diagnostic scans (P = non-significant for all comparisons). Careful application of radiation-dose saving algorithms in appropriately selected patients can reduce the radiation burden of CTCA significantly, without compromising the image quality. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Reduction of uterus dose in clinical thoracic computed tomography.

    PubMed

    Danova, D; Keil, B; Kästner, B; Wulff, J; Fiebich, M; Zink, K; Klose, K J; Heverhagen, J T

    2010-12-01

    The aim of this study was to investigate the potential dose reduction in the uterus as a result of lead apron protection during thoracic CT scans. Moreover, the distribution of the radiation dose in the uterus was determined in order to obtain information about the ratio of internally and externally scattered radiation. The uterus doses during thoracic CT were determined by measuring organ doses using an Alderson-RANDO®-Phantom and thermoluminescent dosimeters. A 0.25 mm lead equivalent protective apron was used to shield the abdominal area. Three measurement conditions were evaluated: without lead apron, covered with lead apron and wrapped with lead apron. The uterus dose with and without shielding describes the mean value and standard deviation of all examinations and all measurement points in the organ. The uterus dose by thoracic CT was measured to be approximately 66.5 ± 3.1 µGy. If the abdomen is covered with a 0.25 mm Pb equivalent lead apron in the front area and on both sides, the uterus dose is reduced to 49.4 ± 2.8 µGy (26% reduction, p < 0.001). If a lead apron is wrapped around the abdomen, providing 0.50 mm Pb shielding in the anterior section due to overlap, and 0.25 mm Pb in the posterior section and on both sides, the uterus dose is reduced even more to 43.8 ± 2.5 µGy (34% reduction, p < 0.001). The dose distribution when the lead apron covers the abdomen shows that the shielding is effective for the scatter radiation that comes from the anterior part. Moreover, the wrapped apron protects the uterus from all directions and is even more effective for dose reduction than the covering apron. Our findings demonstrate that protective aprons are an effective dose reduction technique without additional costs and little effect on patient examination time. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Effective dose span of ten different cone beam CT devices.

    PubMed

    Rottke, D; Patzelt, S; Poxleitner, P; Schulze, D

    2013-01-01

    Evaluation and reduction of dose are important issues. Since cone beam CT (CBCT) has been established now not just in dentistry, the number of acquired examinations continues to rise. Unfortunately, it is very difficult to compare the doses of available devices on the market owing to different exposition parameters, volumes and geometries. The aim of this study was to evaluate the spans of effective doses (EDs) of ten different CBCT devices. 48 thermoluminescent dosemeters were placed in 24 sites in a RANDO(®) head phantom. Protocols with lowest exposition parameters and protocols with highest exposition parameters were performed for each of the ten devices. The ED was calculated from the measured energy doses according to the International Commission on Radiological Protection 2007 recommendations for each protocol and device, and the statistical values were evaluated afterwards. The calculation of the ED resulted in values between 17.2 µSv and 396 µSv for the ten devices. The mean values for protocols with lowest and highest exposition parameters were 31.6 µSv and 209 µSv, respectively. It was not the aim of this study to evaluate the image quality depending on different exposition parameters but to define the spans of EDs in which different CBCT devices work. There is a wide span of ED for different CBCT devices depending on the selected exposition parameters, required spatial resolution and many other factors.

  19. Effective dose span of ten different cone beam CT devices

    PubMed Central

    Rottke, D; Patzelt, S; Poxleitner, P; Schulze, D

    2013-01-01

    Objectives: Evaluation and reduction of dose are important issues. Since cone beam CT (CBCT) has been established now not just in dentistry, the number of acquired examinations continues to rise. Unfortunately, it is very difficult to compare the doses of available devices on the market owing to different exposition parameters, volumes and geometries. The aim of this study was to evaluate the spans of effective doses (EDs) of ten different CBCT devices. Methods: 48 thermoluminescent dosemeters were placed in 24 sites in a RANDO® head phantom. Protocols with lowest exposition parameters and protocols with highest exposition parameters were performed for each of the ten devices. The ED was calculated from the measured energy doses according to the International Commission on Radiological Protection 2007 recommendations for each protocol and device, and the statistical values were evaluated afterwards. Results: The calculation of the ED resulted in values between 17.2 µSv and 396 µSv for the ten devices. The mean values for protocols with lowest and highest exposition parameters were 31.6 µSv and 209 µSv, respectively. Conclusions: It was not the aim of this study to evaluate the image quality depending on different exposition parameters but to define the spans of EDs in which different CBCT devices work. There is a wide span of ED for different CBCT devices depending on the selected exposition parameters, required spatial resolution and many other factors. PMID:23584925

  20. Low dose dynamic myocardial CT perfusion using advanced iterative reconstruction

    NASA Astrophysics Data System (ADS)

    Eck, Brendan L.; Fahmi, Rachid; Fuqua, Christopher; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2015-03-01

    Dynamic myocardial CT perfusion (CTP) can provide quantitative functional information for the assessment of coronary artery disease. However, x-ray dose in dynamic CTP is high, typically from 10mSv to >20mSv. We compared the dose reduction potential of advanced iterative reconstruction, Iterative Model Reconstruction (IMR, Philips Healthcare, Cleveland, Ohio) to hybrid iterative reconstruction (iDose4) and filtered back projection (FBP). Dynamic CTP scans were obtained using a porcine model with balloon-induced ischemia in the left anterior descending coronary artery to prescribed fractional flow reserve values. High dose dynamic CTP scans were acquired at 100kVp/100mAs with effective dose of 23mSv. Low dose scans at 75mAs, 50mAs, and 25mAs were simulated by adding x-ray quantum noise and detector electronic noise to the projection space data. Images were reconstructed with FBP, iDose4, and IMR at each dose level. Image quality in static CTP images was assessed by SNR and CNR. Blood flow was obtained using a dynamic CTP analysis pipeline and blood flow image quality was assessed using flow-SNR and flow-CNR. IMR showed highest static image quality according to SNR and CNR. Blood flow in FBP was increasingly over-estimated at reduced dose. Flow was more consistent for iDose4 from 100mAs to 50mAs, but was over-estimated at 25mAs. IMR was most consistent from 100mAs to 25mAs. Static images and flow maps for 100mAs FBP, 50mAs iDose4, and 25mAs IMR showed comparable, clear ischemia, CNR, and flow-CNR values. These results suggest that IMR can enable dynamic CTP at significantly reduced dose, at 5.8mSv or 25% of the comparable 23mSv FBP protocol.

  1. Automatic radiation dose monitoring for CT of trauma patients with different protocols: feasibility and accuracy.

    PubMed

    Higashigaito, K; Becker, A S; Sprengel, K; Simmen, H-P; Wanner, G; Alkadhi, H

    2016-09-01

    To demonstrate the feasibility and accuracy of automatic radiation dose monitoring software for computed tomography (CT) of trauma patients in a clinical setting over time, and to evaluate the potential of radiation dose reduction using iterative reconstruction (IR). In a time period of 18 months, data from 378 consecutive thoraco-abdominal CT examinations of trauma patients were extracted using automatic radiation dose monitoring software, and patients were split into three cohorts: cohort 1, 64-section CT with filtered back projection, 200 mAs tube current-time product; cohort 2, 128-section CT with IR and identical imaging protocol; cohort 3, 128-section CT with IR, 150 mAs tube current-time product. Radiation dose parameters from the software were compared with the individual patient protocols. Image noise was measured and image quality was semi-quantitatively determined. Automatic extraction of radiation dose metrics was feasible and accurate in all (100%) patients. All CT examinations were of diagnostic quality. There were no differences between cohorts 1 and 2 regarding volume CT dose index (CTDIvol; p=0.62), dose-length product (DLP), and effective dose (ED, both p=0.95), while noise was significantly lower (chest and abdomen, both -38%, p<0.017). Compared to cohort 1, CTDIvol, DLP, and ED in cohort 3 were significantly lower (all -25%, p<0.017), similar to the noise in the chest (-32%) and abdomen (-27%, both p<0.017). Compared to cohort 2, CTDIvol (-28%), DLP, and ED (both -26%) in cohort 3 was significantly lower (all, p<0.017), while noise in the chest (+9%) and abdomen (+18%) was significantly higher (all, p<0.017). Automatic radiation dose monitoring software is feasible and accurate, and can be implemented in a clinical setting for evaluating the effects of lowering radiation doses of CT protocols over time. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  2. Methods for clinical evaluation of noise reduction techniques in abdominopelvic CT.

    PubMed

    Ehman, Eric C; Yu, Lifeng; Manduca, Armando; Hara, Amy K; Shiung, Maria M; Jondal, Dayna; Lake, David S; Paden, Robert G; Blezek, Daniel J; Bruesewitz, Michael R; McCollough, Cynthia H; Hough, David M; Fletcher, Joel G

    2014-01-01

    Most noise reduction methods involve nonlinear processes, and objective evaluation of image quality can be challenging, since image noise cannot be fully characterized on the sole basis of the noise level at computed tomography (CT). Noise spatial correlation (or noise texture) is closely related to the detection and characterization of low-contrast objects and may be quantified by analyzing the noise power spectrum. High-contrast spatial resolution can be measured using the modulation transfer function and section sensitivity profile and is generally unaffected by noise reduction. Detectability of low-contrast lesions can be evaluated subjectively at varying dose levels using phantoms containing low-contrast objects. Clinical applications with inherent high-contrast abnormalities (eg, CT for renal calculi, CT enterography) permit larger dose reductions with denoising techniques. In low-contrast tasks such as detection of metastases in solid organs, dose reduction is substantially more limited by loss of lesion conspicuity due to loss of low-contrast spatial resolution and coarsening of noise texture. Existing noise reduction strategies for dose reduction have a substantial impact on lowering the radiation dose at CT. To preserve the diagnostic benefit of CT examination, thoughtful utilization of these strategies must be based on the inherent lesion-to-background contrast and the anatomy of interest. The authors provide an overview of existing noise reduction strategies for low-dose abdominopelvic CT, including analytic reconstruction, image and projection space denoising, and iterative reconstruction; review qualitative and quantitative tools for evaluating these strategies; and discuss the strengths and limitations of individual noise reduction methods.

  3. Analysis of patient CT dose data using virtualdose

    NASA Astrophysics Data System (ADS)

    Bennett, Richard

    X-ray computer tomography has many benefits to medical and research applications. Recently, over the last decade CT has had a large increase in usage in hospitals and medical diagnosis. In pediatric care, from 2000 to 2006, abdominal CT scans increased by 49 % and chest CT by 425 % in the emergency room (Broder 2007). Enormous amounts of effort have been performed across multiple academic and government groups to determine an accurate measure of organ dose to patients who undergo a CT scan due to the inherent risks with ionizing radiation. Considering these intrinsic risks, CT dose estimating software becomes a necessary tool that health care providers and radiologist must use to determine many metrics to base the risks versus rewards of having an x-ray CT scan. This thesis models the resultant organ dose as body mass increases for patients with all other related scan parameters fixed. In addition to this,this thesis compares a modern dose estimating software, VirtualDose CT to two other programs, CT-Expo and ImPACT CT. The comparison shows how the software's theoretical basis and the phantom they use to represent the human body affect the range of results in organ dose. CT-Expo and ImPACT CT dose estimating software uses a different model for anatomical representation of the organs in the human body and the results show how that approach dramatically changes the outcome. The results categorizes four datasets as compared to the three software types where the appropriate phantom was available. Modeling was done to simulate chest abdominal pelvis scans and whole body scans. Organ dose difference versus body mass index shows as body mass index (BMI) ranges from 23.5 kg/m 2 to 45 kg/m2 the amount of organ dose also trends a percent change from -4.58 to -176.19 %. Comparing organ dose difference with increasing x-ray tube potential from 120 kVp to 140 kVp the percent change in organ dose increases from 55 % to 65 % across all phantoms. In comparing VirtualDose to CT

  4. Automated extraction of radiation dose information for CT examinations.

    PubMed

    Cook, Tessa S; Zimmerman, Stefan; Maidment, Andrew D A; Kim, Woojin; Boonn, William W

    2010-11-01

    Exposure to radiation as a result of medical imaging is currently in the spotlight, receiving attention from Congress as well as the lay press. Although scanner manufacturers are moving toward including effective dose information in the Digital Imaging and Communications in Medicine headers of imaging studies, there is a vast repository of retrospective CT data at every imaging center that stores dose information in an image-based dose sheet. As such, it is difficult for imaging centers to participate in the ACR's Dose Index Registry. The authors have designed an automated extraction system to query their PACS archive and parse CT examinations to extract the dose information stored in each dose sheet. First, an open-source optical character recognition program processes each dose sheet and converts the information to American Standard Code for Information Interchange (ASCII) text. Each text file is parsed, and radiation dose information is extracted and stored in a database which can be queried using an existing pathology and radiology enterprise search tool. Using this automated extraction pipeline, it is possible to perform dose analysis on the >800,000 CT examinations in the PACS archive and generate dose reports for all of these patients. It is also possible to more effectively educate technologists, radiologists, and referring physicians about exposure to radiation from CT by generating report cards for interpreted and performed studies. The automated extraction pipeline enables compliance with the ACR's reporting guidelines and greater awareness of radiation dose to patients, thus resulting in improved patient care and management.

  5. Dose reduction at nuclear power plants

    SciTech Connect

    Baum, J.W.; Dionne, B.J.

    1983-01-01

    The collective dose equivalent at nuclear power plants increased from 1250 rem in 1969 to nearly 54,000 rem in 1980. This rise is attributable primarily to an increase in nuclear generated power from 1289 MW-y to 29,155 MW-y; and secondly, to increased average plant age. However, considerable variation in exposure occurs from plant to plant depending on plant type, refueling, maintenance, etc. In order to understand the factors influencing these differences, an investigation was initiated to study dose-reduction techniques and effectiveness of as low as reasonably achievable (ALARA) planning at light water plants. Objectives are to: identify high-dose maintenance tasks and related dose-reduction techniques; investigate utilization of high-reliability, low-maintenance equipment; recommend improved radioactive waste handling equipment and procedures; examine incentives for dose reduction; and compile an ALARA handbook.

  6. Development of CT scanner models for patient organ dose calculations using Monte Carlo methods

    NASA Astrophysics Data System (ADS)

    Gu, Jianwei

    There is a serious and growing concern about the CT dose delivered by diagnostic CT examinations or image-guided radiation therapy imaging procedures. To better understand and to accurately quantify radiation dose due to CT imaging, Monte Carlo based CT scanner models are needed. This dissertation describes the development, validation, and application of detailed CT scanner models including a GE LightSpeed 16 MDCT scanner and two image guided radiation therapy (IGRT) cone beam CT (CBCT) scanners, kV CBCT and MV CBCT. The modeling process considered the energy spectrum, beam geometry and movement, and bowtie filter (BTF). The methodology of validating the scanner models using reported CTDI values was also developed and implemented. Finally, the organ doses to different patients undergoing CT scan were obtained by integrating the CT scanner models with anatomically-realistic patient phantoms. The tube current modulation (TCM) technique was also investigated for dose reduction. It was found that for RPI-AM, thyroid, kidneys and thymus received largest dose of 13.05, 11.41 and 11.56 mGy/100 mAs from chest scan, abdomen-pelvis scan and CAP scan, respectively using 120 kVp protocols. For RPI-AF, thymus, small intestine and kidneys received largest dose of 10.28, 12.08 and 11.35 mGy/100 mAs from chest scan, abdomen-pelvis scan and CAP scan, respectively using 120 kVp protocols. The dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. For MDCT with TCM schemas, the fetal dose can be reduced with 14%-25%. To demonstrate the applicability of the method proposed in this dissertation for modeling the CT scanner, additional MDCT scanner was modeled and validated by using the measured CTDI values. These results demonstrated that the

  7. Ultra-Low-Dose Fetal CT With Model-Based Iterative Reconstruction: A Prospective Pilot Study.

    PubMed

    Imai, Rumi; Miyazaki, Osamu; Horiuchi, Tetsuya; Asano, Keisuke; Nishimura, Gen; Sago, Haruhiko; Nosaka, Shunsuke

    2017-06-01

    Prenatal diagnosis of skeletal dysplasia by means of 3D skeletal CT examination is highly accurate. However, it carries a risk of fetal exposure to radiation. Model-based iterative reconstruction (MBIR) technology can reduce radiation exposure; however, to our knowledge, the lower limit of an optimal dose is currently unknown. The objectives of this study are to establish ultra-low-dose fetal CT as a method for prenatal diagnosis of skeletal dysplasia and to evaluate the appropriate radiation dose for ultra-low-dose fetal CT. Relationships between tube current and image noise in adaptive statistical iterative reconstruction and MBIR were examined using a 32-cm CT dose index (CTDI) phantom. On the basis of the results of this examination and the recommended methods for the MBIR option and the known relationship between noise and tube current for filtered back projection, as represented by the expression SD = (milliamperes)(-0.5), the lower limit of the optimal dose in ultra-low-dose fetal CT with MBIR was set. The diagnostic power of the CT images obtained using the aforementioned scanning conditions was evaluated, and the radiation exposure associated with ultra-low-dose fetal CT was compared with that noted in previous reports. Noise increased in nearly inverse proportion to the square root of the dose in adaptive statistical iterative reconstruction and in inverse proportion to the fourth root of the dose in MBIR. Ultra-low-dose fetal CT was found to have a volume CTDI of 0.5 mGy. Prenatal diagnosis was accurately performed on the basis of ultra-low-dose fetal CT images that were obtained using this protocol. The level of fetal exposure to radiation was 0.7 mSv. The use of ultra-low-dose fetal CT with MBIR led to a substantial reduction in radiation exposure, compared with the CT imaging method currently used at our institution, but it still enabled diagnosis of skeletal dysplasia without reducing diagnostic power.

  8. Low-voltage chest CT: another way to reduce the radiation dose in asbestos-exposed patients.

    PubMed

    Macía-Suárez, D; Sánchez-Rodríguez, E; Lopez-Calviño, B; Diego, C; Pombar, M

    2017-09-01

    To assess whether low voltage chest computed tomography (CT) can be used to successfully diagnose disease in patients with asbestos exposure. Fifty-six former employees of the shipbuilding industry, who were candidates to receive a standard-dose chest CT due to their occupational exposure to asbestos, underwent a routine CT. Immediately after this initial CT, they underwent a second acquisition using low-dose chest CT parameters, based on a low potential (80 kV) and limited tube current. The findings of the two CT protocols were compared based on typical diseases associated with asbestos exposure. The kappa coefficient for each parameter and for an overall rating (grouping them based on mediastinal, pleural, and pulmonary findings) were calculated in order to test for correlations between the two protocols. A good correlation between routine and low-dose CT was demonstrated for most parameters with a mean radiation dose reduction of up to 83% of the effective dose based on the dose-length product between protocols. Low-dose chest CT, based on a limited tube potential, is useful for patients with an asbestos exposure background. Low-dose chest CT can be successfully used to minimise the radiation dose received by patients, as this protocol produced an estimated mean effective dose similar to that of an abdominal or pelvis plain film. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Simulation of dose reduction in tomosynthesis

    SciTech Connect

    Svalkvist, Angelica; Baath, Magnus

    2010-01-15

    Purpose: Methods for simulating dose reduction are valuable tools in the work of optimizing radiographic examinations. Using such methods, clinical images can be simulated to have been collected at other, lower, dose levels without the need of additional patient exposure. A recent technology introduced to healthcare that needs optimization is tomosynthesis, where a number of low-dose projection images collected at different angles is used to reconstruct section images of an imaged object. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems, suitable for tomosynthesis. Methods: The developed method uses information about the noise power spectrum (NPS) at the original dose level and the simulated dose level to create a noise image that is added to the original image to produce an image that has the same noise properties as an image actually collected at the simulated dose level. As the detective quantum efficiency (DQE) of digital detectors operating at the low dose levels used for tomosynthesis may show a strong dependency on the dose level, it is important that a method for simulating dose reduction for tomosynthesis takes this dependency into account. By applying an experimentally determined relationship between pixel mean and pixel variance, variations in both dose and DQE in relevant dose ranges are taken into account. Results: The developed method was tested on a chest tomosynthesis system and was shown to produce NPS of simulated dose-reduced projection images that agreed well with the NPS of images actually collected at the simulated dose level. The simulated dose reduction method was also applied to tomosynthesis examinations of an anthropomorphic chest phantom, and the obtained noise in the reconstructed section images was very similar to that of an examination actually performed at the simulated dose level. Conclusions: In conclusion, the present article describes a method for simulating dose

  10. Spectrotemporal CT data acquisition and reconstruction at low dose

    SciTech Connect

    Clark, Darin P.; Badea, Cristian T.; Lee, Chang-Lung; Kirsch, David G.

    2015-11-15

    problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. Results: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. Conclusions: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time.

  11. Effective dose estimation during conventional and CT urography

    NASA Astrophysics Data System (ADS)

    Alzimami, K.; Sulieman, A.; Omer, E.; Suliman, I. I.; Alsafi, K.

    2014-11-01

    Intravenous urography (IVU) and CT urography (CTU) are efficient radiological examinations for the evaluation of the urinary system disorders. However patients are exposed to a significant radiation dose. The objectives of this study are to: (i) measure and compare patient radiation dose by computed tomography urography (CTU) and conventional intravenous urography (IVU) and (ii) evaluate organ equivalent dose and cancer risks from CTU and IVU imaging procedures. A total of 141 patients were investigated. A calibrated CT machine (Siemens-Somatom Emotion duo) was used for CTU, while a Shimadzu X ray machine was used for IVU. Thermoluminescence dosimeters (TLD-GR200A) were used to measure patients' entrance surface doses (ESD). TLDs were calibrated under reproducible reference conditions. Patients radiation dose values (DLP) for CTU were 172±61 mGy cm, CTDIvol 4.75±2 mGy and effective dose 2.58±1 mSv. Patient cancer probabilities were estimated to be 1.4 per million per CTU examination. Patients ESDs values for IVU were 21.62±5 mGy, effective dose 1.79±1 mSv. CT involves a higher effective dose than IVU. In this study the radiation dose is considered low compared to previous studies. The effective dose from CTU procedures was 30% higher compared to IVU procedures. Wide dose variation between patient doses suggests that optimization is not fulfilled yet.

  12. TU-PIS-Exhibit Hall-01: CT Dose Optimization Technologies II

    SciTech Connect

    Driesser, I; Angel, E

    2014-06-15

    their institutions. Here Siemens offers the right dose management tools for administrations to analyze and document dose, to train their clinical staff and to continuously optimize the application of the right dose in clinical routine. Siemens CT is not only adhering to the ALARA principle, but is inspired by it. With CARE Right Siemens show their commitment to the right dose in CT. Toshiba Aquilion CT Dose Management Tools Presentation Time: 11:45 - 12:15 PM A practical review of Toshiba’s CT dose management technologies from the physicist’s perspective. This presentation will include an overview of Toshiba’s CT dose reduction technologies and dose safeguards. Content will include answers to frequently asked questions relating to dose management, dose tracking, CTDI measurement, ACR accreditation, ACR QC, and protocol review on Toshiba CT systems. Specific topics will include the following: Toshiba’s mechanism of tube current modulation; Exposure record format and interpretation of the values; Dose reporting and dose safeguard tools; Use of AIDR 3D iterative reconstruction; The configuration of task specific image quality target and its integration with AIDR 3D; Tips for scanning the ACR phantom with wide beam geometry; Measuring CTDI for wide beam geometry; Discussion of daily QC procedures and specifications; Tips for annual QC evaluation; Protocol management tools.

  13. TU-EF-204-03: Task-Based KV and MAs Optimization for Radiation Dose Reduction in CT: From FBP to Statistical Model-Based Iterative Reconstruction (MBIR)

    SciTech Connect

    Gomez-Cardona, D; Li, K; Lubner, M G; Pickhardt, P J; Chen, G-H

    2015-06-15

    Purpose: The introduction of the highly nonlinear MBIR algorithm to clinical CT systems has made CNR an invalid metric for kV optimization. The purpose of this work was to develop a task-based framework to unify kV and mAs optimization for both FBP- and MBIR-based CT systems. Methods: The kV-mAs optimization was formulated as a constrained minimization problem: to select kV and mAs to minimize dose under the constraint of maintaining the detection performance as clinically prescribed. To experimentally solve this optimization problem, exhaustive measurements of detectability index (d’) for a hepatic lesion detection task were performed at 15 different mA levels and 4 kV levels using an anthropomorphic phantom. The measured d’ values were used to generate an iso-detectability map; similarly, dose levels recorded at different kV-mAs combinations were used to generate an iso-dose map. The iso-detectability map was overlaid on top of the iso-dose map so that for a prescribed detectability level d’, the optimal kV-mA can be determined from the crossing between the d’ contour and the dose contour that corresponds to the minimum dose. Results: Taking d’=16 as an example: the kV-mAs combinations on the measured iso-d’ line of MBIR are 80–150 (3.8), 100–140 (6.6), 120–150 (11.3), and 140–160 (17.2), where values in the parentheses are measured dose values. As a Result, the optimal kV was 80 and optimal mA was 150. In comparison, the optimal kV and mA for FBP were 100 and 500, which corresponded to a dose level of 24 mGy. Results of in vivo animal experiments were consistent with the phantom results. Conclusion: A new method to optimize kV and mAs selection has been developed. This method is applicable to both linear and nonlinear CT systems such as those using MBIR. Additional dose savings can be achieved by combining MBIR with this method. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona, M. G

  14. Fetal dose estimates for CT pelvimetry

    SciTech Connect

    Moore, M.M.; Shearer, D.R.

    1989-04-01

    Fetal and maternal dose estimates for computed tomographic pelvimetry have been obtained from phantom measurements. Use of routine abdomen imaging techniques may result in localized fetal doses in excess of 13 mGy (1.3 rad). With the use of a low-exposure (40-mAs) technique, it is possible to obtain images of acceptable quality for the necessary measurements. The resulting dose to the fetus is approximately 2.3 mGy (0.23 rad).

  15. Effect of a small number of training cases on the performance of massive training artificial neural network (MTANN) for reduction of false positives in computerized detection of lung nodules in low-dose CT

    NASA Astrophysics Data System (ADS)

    Suzuki, Kenji; Armato, Samuel G., III; Li, Feng; Sone, Shusuke; Doi, Kunio

    2003-05-01

    In this study, we investigated a pattern-classification technique which can be trained with a small number of cases with a massive training artificial neural network (MTANN) for reduction of false positives in computerized detection of lung nodules in low-dose CT (LDCT). The MTANN consists of a modified multilayer artificial neural network (ANN), which is capable of operating on image data directly. The MTANN is trained by use of a large number of sub-regions extracted from input images together with the teacher images containing the distribution for the "likelihood of being a nodule." The output image is obtained by scanning of an input image with the MTANN. In the MTANN, the distinction between nodules and non-nodules is treated as an image-processing task, in other words, as a highly nonlinear filter that performs both nodule enhancement and non-nodule suppression. This allows us to train the MTANN not on a case basis, but on a sub-region basis. Therefore, the MTANN can be trained with a very small number of cases. Our database consisted of 101 LDCT scans acquired from 71 patients in a lung cancer screening program. The scans consisted of 2,822 sections, and contained 121 nodules including 104 nodules representing confirmed primary cancers. With our current CAD scheme, a sensitivity of 81.0% (98/121 nodules) with 0.99 false positives per section (2,804/2,822) was achieved. By use of the MTANN trained with a small number of training cases (n=10), i.e., five pairs of nodules and non-nodules, we were able to remove 55.8% of false positives without a reduction in the number of true positives, i.e., a classification sensitivity of 100%. Thus, the false-positive rate of our current CAD scheme was reduced from 0.99 to 0.44 false positive per section, while the current sensitivity (81.0%) was maintained.

  16. Personalized technologist dose audit feedback for reducing patient radiation exposure from CT.

    PubMed

    Miglioretti, Diana L; Zhang, Yue; Johnson, Eric; Lee, Choonsik; Morin, Richard L; Vanneman, Nicholas; Smith-Bindman, Rebecca

    2014-03-01

    The aim of this study was to determine whether providing radiologic technologists with audit feedback on doses from CT examinations they conduct and education on dose-reduction strategies reduces patients' radiation exposure. This prospective, controlled pilot study was conducted within an integrated health care system from November 2010 to October 2011. Ten technologists at 2 facilities received personalized dose audit reports and education on dose-reduction strategies; 9 technologists at a control facility received no intervention. Radiation exposure was measured by the dose-length product (DLP) from CT scans performed before (n = 1,630) and after (n = 1,499) the intervention and compared using quantile regression. Technologists were surveyed before and after the intervention. For abdominal CT, DLPs decreased by 3% to 12% at intervention facilities but not at the control facility. For brain CT, DLPs significantly decreased by 7% to 12% at one intervention facility; did not change at the second intervention facility, which had the lowest preintervention DLPs; and increased at the control facility. Technologists were more likely to report always thinking about radiation exposure and associated cancer risk and optimizing settings to reduce exposure after the intervention. Personalized audit feedback and education can change technologists' attitudes about, and awareness of, radiation and can lower patient radiation exposure from CT imaging. Copyright © 2014 American College of Radiology. All rights reserved.

  17. Estimation of Observer Performance for Reduced Radiation Dose Levels in CT: Eliminating Reduced Dose Levels That Are Too Low Is the First Step.

    PubMed

    Fletcher, Joel G; Yu, Lifeng; Fidler, Jeff L; Levin, David L; DeLone, David R; Hough, David M; Takahashi, Naoki; Venkatesh, Sudhakar K; Sykes, Anne-Marie G; White, Darin; Lindell, Rebecca M; Kotsenas, Amy L; Campeau, Norbert G; Lehman, Vance T; Bartley, Adam C; Leng, Shuai; Holmes, David R; Toledano, Alicia Y; Carter, Rickey E; McCollough, Cynthia H

    2017-07-01

    This study aims to estimate observer performance for a range of dose levels for common computed tomography (CT) examinations (detection of liver metastases or pulmonary nodules, and cause of neurologic deficit) to prioritize noninferior dose levels for further analysis. Using CT data from 131 examinations (abdominal CT, 44; chest CT, 44; head CT, 43), CT images corresponding to 4%-100% of the routine clinical dose were reconstructed with filtered back projection or iterative reconstruction. Radiologists evaluated CT images, marking specified targets, providing confidence scores, and grading image quality. Noninferiority was assessed using reference standards, reader agreement rules, and jackknife alternative free-response receiver operating characteristic figures of merit. Reader agreement required that a majority of readers at lower dose identify target lesions seen by the majority of readers at routine dose. Reader agreement identified dose levels lower than 50% and 4% to have inadequate performance for detection of hepatic metastases and pulmonary nodules, respectively, but could not exclude any low dose levels for head CT. Estimated differences in jackknife alternative free-response receiver operating characteristic figures of merit between routine and lower dose configurations found that only the lowest dose configurations tested (ie, 30%, 4%, and 10% of routine dose levels for abdominal, chest, and head CT examinations, respectively) did not meet criteria for noninferiority. At lower doses, subjective image quality declined before observer performance. Iterative reconstruction was only beneficial when filtered back projection did not result in noninferior performance. Opportunity exists for substantial radiation dose reduction using existing CT technology for common diagnostic tasks. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  18. Investigation of ultra low-dose scans in the context of quantum-counting clinical CT

    NASA Astrophysics Data System (ADS)

    Weidinger, T.; Buzug, T. M.; Flohr, T.; Fung, G. S. K.; Kappler, S.; Stierstorfer, K.; Tsui, B. M. W.

    2012-03-01

    In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.

  19. Low-dose CT for quantitative analysis in acute respiratory distress syndrome

    DTIC Science & Technology

    2013-08-31

    few studies on pulmonary emphysema [22-24], that showed that quantification of hyperinflated tissue is not affected by a reduction of tube current...Pulmonary emphysema : radiation dose and section thickness at multidetector CT quantification--comparison with macroscopic and microscopic...pulmonary emphysema using a low-dose technique. Radiol Med 2002, 104:13-24. 24. Nishio M, Matsumoto S, Ohno Y, Sugihara N, Inokawa H, Yoshikawa T

  20. Friction Reduction for Microhole CT Drilling

    SciTech Connect

    Ken Newman; Patrick Kelleher; Edward Smalley

    2007-03-31

    The objective of this 24 month project focused on improving microhole coiled tubing drilling bottom hole assembly (BHA) reliability and performance, while reducing the drilling cost and complexity associated with inclined/horizontal well sections. This was to be accomplished by eliminating the need for a downhole drilling tractor or other downhole coiled tubing (CT) friction mitigation techniques when drilling long (>2,000 ft.) of inclined/horizontal wellbore. The technical solution to be developed and evaluated in this project was based on vibrating the coiled tubing at surface to reduce the friction along the length of the downhole CT drillstring. The Phase 1 objective of this project centered on determining the optimum surface-applied vibration system design for downhole CT friction mitigation. Design of the system would be based on numerical modeling and laboratory testing of the CT friction mitigation achieved with various types of surface-applied vibration. A numerical model was developed to predict how far downhole the surface-applied vibration would travel. A vibration test fixture, simulating microhole CT drilling in a horizontal wellbore, was constructed and used to refine and validate the numerical model. Numerous tests, with varying surface-applied vibration parameters were evaluated in the vibration test fixture. The data indicated that as long as the axial force on the CT was less than the helical buckling load, axial vibration of the CT was effective at mitigating friction. However, surface-applied vibration only provided a small amount of friction mitigation as the helical buckling load on the CT was reached or exceeded. Since it would be impractical to assume that routine field operations be conducted at less than the helical buckling load of the CT, it was determined that this technical approach did not warrant the additional cost and maintenance issues that would be associated with the surface vibration equipment. As such, the project was

  1. Radiation dose of cardiac CT--what is the evidence?

    PubMed

    Alkadhi, Hatem

    2009-06-01

    Current evidence and most pertinent literature on the radiation dose of cardiac computed tomography (CT) for the noninvasive assessment of coronary artery disease are reviewed. The various means for adjusting CT protocols to lower the radiation to a level that is as low as reasonably achievable are discussed. It is shown that for the target population of cardiac CT, the direct visualization of the heart and coronary arteries outweighs the hypothetical risk of the investigation, provided that indications are prudent and the protocols appropriate.

  2. Reduction of iodinated contrast medium in CT: feasibility study

    NASA Astrophysics Data System (ADS)

    Nasirudin, Radin A.; Mei, Kai; Kopp, Felix K.; Penchev, Petar; Rummeny, Ernst J.; Fiebich, Martin; Noël, Peter B.

    2015-03-01

    In CT, the magnitude of enhancement is proportional to the amount of contrast medium (CM) injected. However, high doses of iodinated CM pose health risks, ranging from mild side effects to serious complications such as contrast-induced nephropathy (CIN). This work presents a method that enables the reduction of CM dosage, without affecting the diagnostic image quality. The technique proposed takes advantage of the additional spectral information provided by photon-counting CT systems. In the first step, we apply a material decomposition technique on the projection data to discriminate iodine from other materials. Then, we estimated the noise of the decomposed image by calculating the Cramér-Rao lower bound of the parameter estimator. Next, we iteratively reconstruct the iodine-only image by using the decomposed image and the estimation of noise as an input into a maximum-likelihood iterative reconstruction algorithm. Finally, we combine the iodine-only image with the original image to enhance the contrast of low iodine concentrations. The resulting reconstructions show a notably improved contrast in the final images. Quantitatively, the combined image has a significantly improved CNR, while the measured concentrations are closer to the actual concentrations of the iodine. The preliminary results from our technique show the possibility of reducing the clinical dosage of iodine, without affecting the diagnostic image quality.

  3. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose.

    PubMed

    Abdollahi, Hamid; Shiri, Isaac; Salimi, Yazdan; Sarebani, Maghsoud; Mehdinia, Reza; Deevband, Mohammad Reza; Mahdavi, Seied Rabi; Sohrabi, Ahmad; Bitarafan-Rajabi, Ahmad

    2016-12-01

    The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. The mean CTDIvol was 1.34 mGy±0.19 and the mean SSDE was 1.7 mGy±0.16. The mean±SD of effective dose from emission, CT and total dose were 11.5±1.4, 0.49±0.11 and 12.67±1.73 (mSv) respectively. The mean±SD of effective dose from emission, CT and total dose were 11.5±1.4, 0.49±0.11 and 12.67±1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Variations in radiation dose between the same model of multislice CT scanner at different hospitals.

    PubMed

    Koller, C J; Eatough, J P; Bettridge, A

    2003-11-01

    The variation in exposure factors and patient dose, between seven centres using identical multislice CT scanners, was investigated for six standard examinations. Dose values were compared with each other and the relevant diagnostic reference level (DRL) for each examination. The range in weighted CT dose index (CTDI(w)) values between the seven centres was small for abdominal scans and head scans. For other scans however, such as functional endoscopic sinonasal surgery (FESS) the variations in CTDI(w) were as high as a factor of seven between the lowest and the highest values. At one centre a program of dose optimization had been undertaken and this centre had CTDI(w) values ranging from 3% to 64% lower than the average value for the seven centres. This demonstrates that significant dose reduction can be achieved through close collaboration between medical physicists, radiologists and radiographers.

  5. Dual-Energy CT of the Abdomen and Pelvis: Radiation Dose Considerations.

    PubMed

    Grajo, Joseph R; Sahani, Dushyant V

    2017-09-21

    Dual-energy CT offers several new applications and opportunities for routine clinical practice. Increasing utilization in the context of both routine practice and clinical research raises questions about expected radiation dose when compared with conventional single-energy exams. Despite initial concerns, advanced iterative reconstruction techniques and creation of virtual unenhanced images in multiphase acquisitions offer methods for dose reduction. Although dose varies across patients and scanners, modern dual-energy exams allow for comparable and potentially decreased radiation dose when compared with single-energy CT. In this review, we examine dual-energy radiation dose considerations with discussion of accepted ACR diagnostic reference levels. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. Transcriptional effects of gene dose reduction

    PubMed Central

    2014-01-01

    Large-scale gene dose reductions usually lead to abnormal phenotypes or death. However, male mammals, Drosophila, and Caenorhabditis elegans have only one X chromosome and thus can be considered as monosomic for a major chromosome. Despite the deleterious effects brought about by such gene dose reduction in the case of an autosome, X chromosome monosomy in males is natural and innocuous. This is because of the nearly full transcriptional compensation for X chromosome genes in males, as opposed to no or partial transcriptional compensation for autosomal one-dose genes arising due to deletions. Buffering, the passive absorption of disturbance due to enzyme kinetics, and feedback responses triggered by expression change contribute to partial compensation. Feed-forward mechanisms, which are active responses to genes being located on the X, rather than actual gene dose are important contributors to full X chromosome compensation. In the last decade, high-throughput techniques have provided us with the tools to effectively and quantitatively measure the small-fold transcriptional effects of dose reduction. This is leading to a better understanding of compensatory mechanisms. PMID:24581086

  7. MO-DE-204-02: Optimization of the Patient CT Dose in Europe.

    PubMed

    Tsapaki, V

    2016-06-01

    The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented. Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts.

  8. Imaging task-based optimal kV and mA selection for CT radiation dose reduction: from filtered backprojection (FBP) to statistical model based iterative reconstruction (MBIR)

    NASA Astrophysics Data System (ADS)

    Li, Ke; Gomez-Cardona, Daniel; Lubner, Meghan G.; Pickhardt, Perry J.; Chen, Guang-Hong

    2015-03-01

    Optimal selections of tube potential (kV) and tube current (mA) are essential in maximizing the diagnostic potential of a given CT technology while minimizing radiation dose. The use of a lower tube potential may improve image contrast, but may also require a significantly higher tube current to compensate for the rapid decrease of tube output at lower tube potentials. Therefore, the selection of kV and mA should take those kinds of constraints as well as the specific diagnostic imaging task in to consideration. For conventional quasi-linear CT systems employing linear filtered back-projection (FBP) image reconstruction algorithm, the optimization of kV-mA combinations are relatively straightforward, as neither spatial resolution nor noise texture has significant dependence on kV and mA settings. In these cases, zero-frequency analysis such as contrast-to-noise ratio (CNR) or normalized CNR by dose (CNRD) can be used for optimal kV-mA selection. The recently introduced statistical model-based iterative reconstruction (MBIR) method, however, has introduced new challenges to optimal kV and mA selection, as both spatial resolution and noise texture become closely correlated with kV and mA. In this work, a task-based approach based on modern signal detection theory and the corresponding frequency-dependent analysis has been proposed to perform the kV and mA optimization for both FBP and MBIR. By performing exhaustive measurements of task-based detectability index through the technically accessible kV-mA parameter space, iso-detectability contours were generated and overlaid on top of iso-dose contours, from which the kV-mA pair that minimize dose yet still achieving the desired detectability level can be identified.

  9. Detection of bladder cancer: comparison of low-dose scans with AIDR 3D and routine-dose scans with FBP on the excretory phase in CT urography

    PubMed Central

    Tsuboyama, Takahiro; Kumano, Seishi; Inada, Yuki; Koyama, Mitsuhiro; Azuma, Haruhito; Narumi, Yoshifumi

    2016-01-01

    Objective: To prospectively compare the detection of bladder cancer between low-dose scans with adaptive iterative dose reduction three dimensional projection (AIDR 3D) and routine-dose scans with filtered back projection (FBP) on the excretory phase (EP) in CT urography. Methods: 42 patients were included. Routine- and low-dose EP were performed in each patient. Routine-dose images were reconstructed with FBP, and low-dose images were reconstructed with AIDR 3D. Two radiologists scored confidence levels for the presence or absence of bladder cancer using a 5-point scale. The CT dose index of each EP was measured, and the dose reduction was calculated. Results: Sensitivity, specificity and accuracy were 86.4%, 95.0% and 90.5% on routine-dose scans and were 86.4%, 90.0% and 88.1% on low-dose scans, respectively. There was no significant difference (p; not significant, 1.00 and 1.00, respectively). The average CT dose index was 8.07 and 2.63 mGy on routine- and low-dose scans, and the ratio of dose reduction was 67.6%. Conclusion: The detection of bladder cancer on low-dose scans with AIDR 3D is almost equal to that on routine-dose scans with FBP on the EP, with nearly 70% dose reduction. Advances in knowledge: Using AIDR 3D, the radiation dose may be reduced on the EP in CT urography for the detection of bladder cancer. PMID:26642306

  10. Reduced dose CT with model-based iterative reconstruction compared to standard dose CT of the chest, abdomen, and pelvis in oncology patients: intra-individual comparison study on image quality and lesion conspicuity.

    PubMed

    Morimoto, Linda Nayeli; Kamaya, Aya; Boulay-Coletta, Isabelle; Fleischmann, Dominik; Molvin, Lior; Tian, Lu; Fisher, George; Wang, Jia; Willmann, Jürgen K

    2017-04-17

    To compare image quality and lesion conspicuity of reduced dose (RD) CT with model-based iterative reconstruction (MBIR) compared to standard dose (SD) CT in patients undergoing oncological follow-up imaging. Forty-four cancer patients who had a staging SD CT within 12 months were prospectively included to undergo a weight-based RD CT with MBIR. Radiation dose was recorded and tissue attenuation and image noise of four tissue types were measured. Reproducibility of target lesion size measurements of up to 5 target lesions per patient were analyzed. Subjective image quality was evaluated for three readers independently utilizing 4- or 5-point Likert scales. Median radiation dose reduction was 46% using RD CT (P < 0.01). Median image noise across all measured tissue types was lower (P < 0.01) in RD CT. Subjective image quality for RD CT was higher (P < 0.01) in regard to image noise and overall image quality; however, there was no statistically significant difference regarding image sharpness (P = 0.59). There were subjectively more artifacts on RD CT (P < 0.01). Lesion conspicuity was subjectively better in RD CT (P < 0.01). Repeated target lesion size measurements were highly reproducible both on SD CT (ICC = 0.987) and RD CT (ICC = 0.97). RD CT imaging with MBIR provides diagnostic imaging quality and comparable lesion conspicuity on follow-up exams while allowing dose reduction by a median of 46% compared to SD CT imaging.

  11. Patient-specific image denoising for ultra-low-dose CT-guided lung biopsies.

    PubMed

    Green, Michael; Marom, Edith M; Konen, Eli; Kiryati, Nahum; Mayer, Arnaldo

    2017-06-10

    Low-dose CT screening of the lungs is becoming a reality, triggering many more CT-guided lung biopsies. During these biopsies, the patient is submitted to repeated guiding scans with substantial cumulated radiation dose. Extension of the dose reduction to the biopsy procedure is therefore necessary. We propose an image denoising algorithm that specifically addresses the setup of CT-guided lung biopsies. It minimizes radiation exposure while keeping the image quality appropriate for navigation to the target lesion. A database of high-SNR CT patches is used to filter noisy pixels in a non-local means framework, while explicitly enforcing local spatial consistency in order to preserve fine image details and structures. The patch database may be created from a multi-patient set of high-SNR lung scans. Alternatively, the first scan, acquired at high-SNR right before the needle insertion, can provide a convenient patient-specific patch database. The proposed algorithm is compared to state-of-the-art denoising algorithms for a dataset of 43 real CT-guided biopsy scans. Ultra-low-dose scans were simulated by synthetic noise addition to the sinogram, equivalent to a 96% reduction in radiation dose. The feature similarity score for the proposed algorithm outperformed the compared methods for all the scans in the dataset. The benefit of the patient-specific patch database over the multi-patient one is demonstrated in terms of recovered contrast for a tiny porcine lung nodule, following denoising with both approaches. The proposed method provides a promising approach to the denoising of ultra-low-dose CT-guided biopsy images.

  12. CT effective dose per dose length product using ICRP 103 weighting factors

    SciTech Connect

    Huda, Walter; Magill, Dennise; He Wenjun

    2011-03-15

    Purpose: To generate effective dose per unit dose length product (E/DLP) conversion factors incorporating ICRP Publication 103 tissue weighting factors. Methods: Effective doses for CT examinations were obtained using the IMPACT Dosimetry Calculator using all 23 dose data sets that are offered by this spreadsheet. CT examinations were simulated for scans performed along the patient long axis for each dosimetry data set using a 4 cm beam width ranging from the upper thighs to top of the head. Five basic body regions (head, neck, chest, abdomen, and pelvis), as well as combinations of the regions (head/neck, chest/abdomen, abdomen/pelvis, and chest/abdomen/pelvis) and whole body CT scans were investigated. Correction factors were generated that can be applied to convert E/DLP conversion factors based on ICRP 60 data to conversion factors that are valid for ICRP 103 data (i.e., E{sub 103}/E{sub 60}). Results: Use of ICRP 103 weighting factors increase effective doses for head scans by {approx}11%, for chest scans by {approx}20%, and decrease effective doses for pelvis scans by {approx}25%. Current E/DLP conversion factors are estimated to be 2.4 {mu}Sv/mGy cm for head CT examinations and range between 14 and 20 {mu}Sv/mGy cm for body CT examinations. Conclusions: Factors that enable patient CT doses to be adjusted to account for ICRP 103 tissue weighting factors are provided, which result in E/DLP factors that were increased in head and chest CT, reduced in pelvis CT, and showed no marked change in neck and abdomen CT.

  13. PET/CT-guided Interventions: Personnel Radiation Dose

    SciTech Connect

    Ryan, E. Ronan Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P.; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T.; Solomon, Stephen B.

    2013-08-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  14. PET/CT-guided interventions: personnel radiation dose.

    PubMed

    Ryan, E Ronan; Thornton, Raymond; Sofocleous, Constantinos T; Erinjeri, Joseph P; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T; Solomon, Stephen B

    2013-08-01

    To quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures. In this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound). The median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06). The operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  15. Impact of iterative reconstruction on image quality of low-dose CT of the lumbar spine.

    PubMed

    Alshamari, Muhammed; Geijer, Mats; Norrman, Eva; Lidén, Mats; Krauss, Wolfgang; Jendeberg, Johan; Magnuson, Anders; Geijer, Håkan

    2017-06-01

    Background Iterative reconstruction (IR) is a recent reconstruction algorithm for computed tomography (CT) that can be used instead of the standard algorithm, filtered back projection (FBP), to reduce radiation dose and/or improve image quality. Purpose To evaluate and compare the image quality of low-dose CT of the lumbar spine reconstructed with IR to conventional FBP, without further reduction of radiation dose. Material and Methods Low-dose CT on 55 patients was performed on a Siemens scanner using 120 kV tube voltage, 30 reference mAs, and automatic dose modulation. From raw CT data, lumbar spine CT images were reconstructed with a medium filter (B41f) using FBP and four levels of IR (levels 2-5). Five reviewers scored all images on seven image quality criteria according to the European guidelines on quality criteria for CT, using a five-grade scale. A side-by-side comparison was also performed. Results There was significant improvement in image quality for IR (levels 2-4) compared to FBP. According to visual grading regression, odds ratios of all criteria with 95% confidence intervals for IR2, IR3, IR4, and IR5 were: 1.59 (1.39-1.83), 1.74 (1.51-1.99), 1.68 (1.46-1.93), and 1.08 (0.94-1.23), respectively. In the side-by-side comparison of all reconstructions, images with IR (levels 2-4) received the highest scores. The mean overall CTDIvol was 1.70 mGy (SD 0.46; range, 1.01-3.83 mGy). Image noise decreased in a linear fashion with increased strength of IR. Conclusion Iterative reconstruction at levels 2, 3, and 4 improves image quality of low-dose CT of the lumbar spine compared to FPB.

  16. CT Radiation Dose Optimization and Tracking Program at a Large Quaternary-Care Health Care System.

    PubMed

    Goenka, Ajit H; Dong, Frank; Wildman, Bonnie; Hulme, Katie; Johnson, Paul; Herts, Brian R

    2015-07-01

    The authors report the implementation and outcomes of a CT radiation dose optimization and tracking program at a large quaternary-care health care system. A committee reviewed, optimized, and released standardized imaging protocols for the most common CT examinations across the health system. Volume CT dose index and dose-length product (DLP) diagnostic reference levels (DRLs) were established, with the goal of decreasing the percentage of outliers (CT scans with DLPs greater than the established DRLs) to <5% of tracked CT examinations. Baseline radiation dose data were manually extracted for 5% of total examinations. A semiautomated process to analyze all DLP data was then implemented to monitor outliers. The baseline percentage of outliers was slightly higher than 10% for pediatric scans but nearly 26.5% for adult scans. Over the first year, after standardized protocols were distributed, the percentage of outliers decreased for pediatric brain (from 22% to 6%), adult brain (from 23% to 3%), and adult chest (from 22% to 11%) examinations. Over the next 2 years, after the dose-tracking program was implemented, the percentage of outliers decreased for adult (brain, from 3% to 1%; chest, from 11% to 1%; abdomen, from 24% to 1%) and pediatric (brain, from 6% to 2%; chest, from 11% to 0%; abdomen, from 7% to 1%) examinations. The reported CT protocol optimization and dose-tracking program enabled a sustainable reduction in the proportion of CT examinations being performed above established DRLs from as high as 26% to <1% over a period of 2 years. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

    SciTech Connect

    Liao, S; Wang, Y; Weng, H

    2015-06-15

    Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiation dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle.

  18. Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

    PubMed

    Shirasaka, Takashi; Funama, Yoshinori; Hayashi, Mutsukazu; Awamoto, Shinichi; Kondo, Masatoshi; Nakamura, Yasuhiko; Hatakenaka, Masamitsu; Honda, Hiroshi

    2012-01-01

    Our purpose in this study was to assess the radiation dose reduction and the actual exposed scan length of over-range areas using a spiral dynamic z-collimator at different beam pitches and detector coverage. Using glass rod dosimeters, we measured the unilateral over-range scan dose between the beginning of the planned scan range and the beginning of the actual exposed scan range. Scanning was performed at detector coverage of 80.0 and 40.0 mm, with and without the spiral dynamic z-collimator. The dose-saving ratio was calculated as the ratio of the unnecessary over-range dose, with and without the spiral dynamic z-collimator. In 80.0 mm detector coverage without the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 108, 120, and 126 mm, corresponding to a beam pitch of 0.60, 0.80, and 0.99, respectively. With the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 48, 66, and 84 mm with a beam pitch of 0.60, 0.80, and 0.99, respectively. The dose-saving ratios with and without the spiral dynamic z-collimator for a beam pitch of 0.60, 0.80, and 0.99 were 35.07, 24.76, and 13.51%, respectively. With 40.0 mm detector coverage, the dose-saving ratios with and without the spiral dynamic z-collimator had the highest value of 27.23% with a low beam pitch of 0.60. The spiral dynamic z-collimator is important for a reduction in the unnecessary over-range dose and makes it possible to reduce the unnecessary dose by means of a lower beam pitch.

  19. Screening for lung cancer with low-dose CT.

    PubMed

    Coche, E

    2008-01-01

    Lung cancer represents the leading cause of cancer-related mortality in the world. In the past, many attempts were made to detect the disease at an early stage and subsequently reduce its mortality. Chest X-ray was abandoned for this purpose. For several years low-dose computed tomography has been introduced as a potential tool for early screening in a high-risk population. As demonstrated in several papers, the task is not easy and researchers are faced with many difficulties. This paper reviews mainly the role of low-dose CT for early cancer screening. Results of past and current trials, controversies related to the high rate of lung nodules, cost-effectiveness, and delivered radiation dose to the patient are presented. Finally some limitations of low dose CT for lung cancer detection are explained.

  20. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    PubMed

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  1. Dose calculation using megavoltage cone-beam CT

    SciTech Connect

    Morin, Olivier . E-mail: Morin@radonc17.ucsf.edu; Chen, Josephine; Aubin, Michele; Gillis, Amy; Aubry, Jean-Francois; Bose, Supratik; Chen Hong; Descovich, Martina; Xia Ping; Pouliot, Jean

    2007-03-15

    Purpose: To demonstrate the feasibility of performing dose calculation on megavoltage cone-beam CT (MVCBCT) of head-and-neck patients in order to track the dosimetric errors produced by anatomic changes. Methods and Materials: A simple geometric model was developed using a head-size water cylinder to correct an observed cupping artifact occurring with MVCBCT. The uniformity-corrected MVCBCT was calibrated for physical density. Beam arrangements and weights from the initial treatment plans defined using the conventional CT were applied to the MVCBCT image, and the dose distribution was recalculated. The dosimetric inaccuracies caused by the cupping artifact were evaluated on the water phantom images. An ideal test patient with no observable anatomic changes and a patient imaged with both CT and MVCBCT before and after considerable weight loss were used to clinically validate MVCBCT for dose calculation and to determine the dosimetric impact of large anatomic changes. Results: The nonuniformity of a head-size water phantom ({approx}30%) causes a dosimetric error of less than 5%. The uniformity correction method developed greatly reduces the cupping artifact, resulting in dosimetric inaccuracies of less than 1%. For the clinical cases, the agreement between the dose distributions calculated using MVCBCT and CT was better than 3% and 3 mm where all tissue was encompassed within the MVCBCT. Dose-volume histograms from the dose calculations on CT and MVCBCT were in excellent agreement. Conclusion: MVCBCT can be used to estimate the dosimetric impact of changing anatomy on several structures in the head-and-neck region.

  2. SU-E-P-03: Implementing a Low Dose Lung Screening CT Program Meeting Regulatory Requirements

    SciTech Connect

    LaFrance, M; Marsh, S; O'Donnell, G

    2014-06-01

    Purpose: To provide information pertaining to IROC Houston QA Center's (RPC) credentialing process for institutions participating in NCI-sponsored clinical trials. Purpose: Provide guidance to the Radiology Departments with the intent of implementing a Low Dose CT Screening Program using different CT Scanners with multiple techniques within the framework of the required state regulations. Method: State Requirements for the purpose of implementing a Low Dose CT Lung Protocol required working with the Radiology and Pulmonary Department in setting up a Low Dose Screening Protocol designed to reduce the radiation burden to the patients enrolled. Radiation dose measurements (CTDIvol) for various CT manufacturers (Siemens16, Siemens 64, Philips 64, and Neusoft128) for three different weight based protocols. All scans were reviewed by the Radiologist. Prior to starting a low dose lung screening protocol, information had to be submitted to the state for approval. Performing a Healing Arts protocol requires extensive information. This not only includes name and address of the applicant but a detailed description of the disease, the x-ray examination and the population to be examined. The unit had to be tested by a qualified expert using the technique charts. The credentials of all the operators, the supervisors and the Radiologists had to be submitted to the state. Results: All the appropriate documentation was sent to the state for review. The measured results between the Low Dose Protocol versus the default Adult Chest Protocol showed that there was a dose reduction of 65% for small (100-150 lb.) patient, 75% for the Medium patient (151-250 lbs.), and a 55% reduction for the Large patient ( over 250 lbs.). Conclusion: Measured results indicated that the Low Dose Protocol indeed lowered the screening patient's radiation dose and the institution was able to submit the protocol to the State's regulators.

  3. Effect of shaped filter design on dose and image quality in breast CT.

    PubMed

    Lück, Ferdinand; Kolditz, Daniel; Hupfer, Martin; Kalender, Willi A

    2013-06-21

    The purpose of this study was to investigate the effect of shaped filters specifically designed for dedicated breast computed tomography (CT) scanners on dose and image quality. Optimization of filter shape and material in fan direction was performed using two different design methods, one aiming at homogeneous noise distributions in the CT images and the other aiming at a uniform dose distribution in the breast. The optimal filter thickness as a function of fan angle was determined iteratively to fulfil the above mentioned criteria for each breast diameter. Different filter materials (aluminium, copper, carbon, polytetrafluoroethylene) and breast phantoms with diameters between 80-180 mm were investigated. Noise uniformity in the reconstructed images, obtained from CT simulations based on ray-tracing methods, and dose in the breast, calculated with a Monte Carlo software tool, were used as figure of merit. Furthermore, CT-value homogeneity, the distribution of noise in cone direction, spatial resolution from centre to periphery and the contrast-to-noise ratio weighted by dose (CNRD) were evaluated. In addition, the decrease of scatter due to shaped filters was investigated. Since only few or one filter are practical in clinical CT systems, the effects of one shaped filter for different breast diameters were also investigated. In this case the filter, designed for the largest breast diameter, was simulated at variable source-to-filter distances depending on breast diameter. With the filter design method aiming at uniform noise distribution best results were obtained for aluminium as the filter material. Noise uniformity improved from 20} down to 5} and dose was reduced by about 30-40} for all breast diameters. No decrease of noise uniformity in cone direction, CT-value homogeneity, spatial resolution and the CNRD was detected with the shaped filter. However, a small improvement of CNRD was observed. Furthermore, a scatter reduction of about 20-30} and a more

  4. Standardization and optimization of CT protocols to achieve low dose.

    PubMed

    Trattner, Sigal; Pearson, Gregory D N; Chin, Cynthia; Cody, Dianna D; Gupta, Rajiv; Hess, Christopher P; Kalra, Mannudeep K; Kofler, James M; Krishnam, Mayil S; Einstein, Andrew J

    2014-03-01

    The increase in radiation exposure due to CT scans has been of growing concern in recent years. CT scanners differ in their capabilities, and various indications require unique protocols, but there remains room for standardization and optimization. In this paper, the authors summarize approaches to reduce dose, as discussed in lectures constituting the first session of the 2013 UCSF Virtual Symposium on Radiation Safety and Computed Tomography. The experience of scanning at low dose in different body regions, for both diagnostic and interventional CT procedures, is addressed. An essential primary step is justifying the medical need for each scan. General guiding principles for reducing dose include tailoring a scan to a patient, minimizing scan length, use of tube current modulation and minimizing tube current, minimizing tube potential, iterative reconstruction, and periodic review of CT studies. Organized efforts for standardization have been spearheaded by professional societies such as the American Association of Physicists in Medicine. Finally, all team members should demonstrate an awareness of the importance of minimizing dose.

  5. Lung Cancer Screening with Low Dose CT

    PubMed Central

    Caroline, Chiles

    2014-01-01

    SUMMARY The announcement of the results of the NLST, showing a 20% reduction in lung-cancer specific mortality with LDCT screening in a high risk population, marked a turning point in lung cancer screening. This was the first time that a randomized controlled trial had shown a mortality reduction with an imaging modality aimed at early detection of lung cancer. Current guidelines endorse LDCT screening for smokers and former smokers ages 55 to 74, with at least a 30 pack year smoking history. Adherence to published algorithms for nodule follow-up is strongly encouraged. Future directions for screening research include risk stratification for selection of the screening population, and improvements in the diagnostic follow-up for indeterminate pulmonary nodules. As with screening for other malignancies, screening for lung cancer with LDCT has revealed that there are indolent lung cancers which may not be fatal. More research is necessary if we are to maximize the risk-benefit ratio in lung cancer screening. PMID:24267709

  6. Impact of low-dose CT scan in dual timepoint investigations: a phantom study

    NASA Astrophysics Data System (ADS)

    Micheelsen, M. A.; Jensen, M.

    2011-09-01

    Dual timepoint FDG takeup investigations have a potential for separating malignant lymph nodes from non-malignant in certain cases of suspected lung cancer. One hour seems to be the optimal time interval between the two scans (50-120 min). Many of the new PET scanners benefit from image fusion with a CT image and also use the CT for attenuation correction. In any practical hospital setting, 1 hour is too long to occupy the scanner bed and a second CT procedure thus becomes necessary. This study tries to validate to what extent the dose/quality of the second CT scan can be lowered, without compromising attenuation correction, lesion detection and quantification. Using a standard NEMA phantom with the GE Discovery PET/CT scanner, taken in and out between scan sessions, we have tried to find the minimal CT dose necessary for the second scan while still reaching tissue activity quantification within predetermined error limits. For a hot sphere to background activity concentration ratio of 1:5, the average uptake (normalised by the time corrected input activity concentration) in a sphere of 6 cm3 was found to be 0.90 ± 0.08 for the standard scan, yielding a dose of 5.5 mGy, and 0.90 ± 0.14 for a scan with lowest possible mAs product and lowest possible kV, yielding a dose of 0.65 mGy. With an insignificant increase in the uncertainty in the uptake measurement, we can get an order of magnitude reduction for the CT dose.

  7. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study

    PubMed Central

    Grosser, Oliver S.; Kupitz, Dennis; Ruf, Juri; Czuczwara, Damian; Steffen, Ingo G.; Furth, Christian; Thormann, Markus; Loewenthal, David; Ricke, Jens; Amthauer, Holger

    2015-01-01

    Background Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT) or positron emission tomography (PET) with computed tomography (CT). Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR) on the image quality of the low-dose CT images. Methodology/Principal Findings Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU) values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88) and the contrast-to-noise ratio (CNR) was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04). In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001). Conclusion/Significance In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality. PMID:26390216

  8. Utilisation of PACS to monitor patient CT doses.

    PubMed

    AlSuwaidi, J S; Bayoumi, M; Al Shibli, N; Sulaiman, H; Urrahman, T; AlYarah, M

    2011-09-01

    In the past 5 y, the number of computed tomography (CT) studies has doubled at Dubai Health Authority hospitals. This situation, along with patient's overdoses reported internationally, has prompted action to establish a system to manage patient doses incurred due to medical imaging practices. In this work, the authors aim to homogenise dose reporting to monitor radiation dose levels and facilitate the establishment of local and national dose reference levels. The two hospitals enrolled in this study are equipped with three CT systems (two 4 slices and one 64 slices). Through the Picture Archive and Communication Systems (PACS) tracking system, it is mandatory to fill CT patient doses in radiology information system (RIS). Dose length product (mGy cm) was recorded for 2502 adult and 178 paediatric patients. All patients' dosimetry data were collected from the RIS by Cogonos statistical software. The PACS data were reviewed to exclude incomplete data. Average and range of effective doses for adult and paediatric patients were calculated using an appropriate weighting factor. Individual accumulated effective doses for adult and paediatric patients were calculated for 4s-scanner-1 only. Adult average effective doses for the head (1482 exams) were 1.23 ± 0.58, 2.84 ± 0.83 and 2.98 ± 1.103 mSv, the chest (545 exams) were 5.39 ± 1.63, 21.85 ± 5.63 and 18.19 ± 3.22 mSv and for the abdomen and pelvis (1183 exams) were 10.85 ± 4.26, 25.66 ± 8.83 and 26.46 ± 13.75 mSv for 4s-scanner-1, 4s-scanner-2 and 64 s, respectively. The paediatric average effective dose for the head (127 exams) was 1.77 ± 0.82 mSv, for the chest (22 exams) was 3.3 ± 1.29 mSv and for the abdomen and pelvis (27 exams) was 6.16 ± 2.64 mSv. Results of individual accumulated effective doses for adult and paediatric patients were presented. PACS dose reporting facilitated dosimetry clinical auditing. Effective doses obtained in this work demonstrated that the results of one scanner were within

  9. Improvement of image quality and dose management in CT fluoroscopy by iterative 3D image reconstruction.

    PubMed

    Grosser, Oliver S; Wybranski, Christian; Kupitz, Dennis; Powerski, Maciej; Mohnike, Konrad; Pech, Maciej; Amthauer, Holger; Ricke, Jens

    2017-09-01

    The objective of this study was to assess the influence of an iterative CT reconstruction algorithm (IA), newly available for CT-fluoroscopy (CTF), on image noise, readers' confidence and effective dose compared to filtered back projection (FBP). Data from 165 patients (FBP/IA = 82/74) with CTF in the thorax, abdomen and pelvis were included. Noise was analysed in a large-diameter vessel. The impact of reconstruction and variables (e.g. X-ray tube current I) influencing noise and effective dose were analysed by ANOVA and a pairwise t-test with Bonferroni-Holm correction. Noise and readers' confidence were evaluated by three readers. Noise was significantly influenced by reconstruction, I, body region and circumference (all p ≤ 0.0002). IA reduced the noise significantly compared to FBP (p = 0.02). The effect varied for body regions and circumferences (p ≤ 0.001). The effective dose was influenced by the reconstruction, body region, interventional procedure and I (all p ≤ 0.02). The inter-rater reliability for noise and readers' confidence was good (W ≥ 0.75, p < 0.0001). Noise and readers' confidence were significantly better in AIDR-3D compared to FBP (p ≤ 0.03). Generally, IA yielded a significant reduction of the median effective dose. The CTF reconstruction by IA showed a significant reduction in noise and effective dose while readers' confidence increased. • CTF is performed for image guidance in interventional radiology. • Patient exposure was estimated from DLP documented by the CT. • Iterative CT reconstruction is appropriate to reduce image noise in CTF. • Using iterative CT reconstruction, the effective dose was significantly reduced in abdominal interventions.

  10. Variability in Radiation Dose From Repeat Identical CT Examinations: Longitudinal Analysis of 2851 Patients Undergoing 12,635 Thoracoabdominal CT Scans in an Academic Health System.

    PubMed

    Mileto, Achille; Nelson, Rendon C; Larson, Douglas G; Samei, Ehsan; Wilson, Joshua M; Christianson, Olav; Marin, Daniele; Boll, Daniel T

    2017-06-01

    The purpose of this study was to conduct longitudinal analyses of radiation dose data from adult patients undergoing clinically indicated, repeat identical thoracoabdominal CT examinations. Radiation dose data were electronically collected from 2851 subjects undergoing 12,635 repeat identical CT scans (mean number of scans per patient, 4.8; range, 2-33) in one health system. Included CT protocols were chest-abdomen-pelvis with contrast administration (n = 4621 CT studies of 1064 patients), abdomen-pelvis with contrast administration (n = 876 CT studies of 261 patients), renal stone (n = 1053 CT studies of 380 patients), and chest (n = 6085 CT studies of 1146 patients) without contrast administration. A radiation-tracking software infrastructure was adopted to extract data from DICOM headers in PACS. Size-specific dose estimate (SSDE) was calculated. A trend was observed toward global reduction in SSDE values with all protocols investigated (chest-abdomen-pelvis slope, -1.78; abdomen-pelvis slope, -0.82; renal stone slope, -0.83; chest slope, -0.47; p < 0.001 for all comparisons). The intraindividual analyses of radiation dose distribution showed widespread variability in SSDE values across the four protocols investigated (chest-abdomen-pelvis mean coefficient of variance, 14.02 mGy; abdomen-pelvis mean coefficient of variance, 10.26 mGy; renal stone mean coefficient of variance, 34.18 mGy; chest mean coefficient of variance, 6.74 mGy). Although there is a trend toward global reduction in radiation doses, this study showed widespread variability in the radiation dose that each patient undergoing identical repeat thoracoabdominal CT protocols absorbs. These data may provide a foundation for the future development of best-practice guidelines for patient-specific radiation dose monitoring.

  11. In vivo dosimetry for estimation of effective doses in multislice CT coronary angiography

    SciTech Connect

    De Denaro, M.; Bregant, P.; Severgnini, M.; De Guarrini, F.

    2007-10-15

    In vivo dosimetry represents a technique that has been widely employed to evaluate the dose to the patient mainly in radiotherapy. Considering the increment in dose to the population due to new high-dose multislice CT examinations, such as coronary angiography, it is becoming important to more accurately know the dose to the patient. The desire to know patient dose extends even to radiological examinations. Thermoluminescent dosimeters are considered the gold standard for in vivo dosimetry, but their use is time consuming. A rapid, less labor-intensive method has been developed to perform in vivo dosimetry using radiochromic film positioned next to the patient's skin. Multislice CT scanners allow the estimation of the effective dose to the patient from the dose length product (DLP) parameter, the value of which is displayed on the acquisition console, simply multiplying the DLP by published conversion factors. The method represents only an approximation based on standard size circular phantoms and neglects the actual size of the patient. More accurate evaluations can be carried out using software-based Monte Carlo simulations. However, these methods do not consider possible dose reduction techniques, such as automatic tube-current modulation. For 22 patients effective doses measured by in vivo dosimetry and calculated by software were compared. The technique of using in vivo dosimetry measured with radiochromic film appears a promising procedure for improving the assessment of the effective dose to the patient.

  12. MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

    SciTech Connect

    Denison, K; Smith, S

    2014-06-15

    Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The

  13. An improved analytical model for CT dose simulation with a new look at the theory of CT dose

    SciTech Connect

    Dixon, Robert L.; Munley, Michael T.; Bayram, Ersin

    2005-12-15

    Gagne [Med. Phys. 16, 29-37 (1989)] has previously described a model for predicting the sensitivity and dose profiles in the slice-width (z) direction for CT scanners. The model, developed prior to the advent of multidetector CT scanners, is still widely used; however, it does not account for the effect of anode tilt on the penumbra or include the heel effect, both of which are increasingly important for the wider beams (up to 40 mm) of contemporary, multidetector scanners. Additionally, it applied only on (or near) the axis of rotation, and did not incorporate the photon energy spectrum. The improved model described herein transcends all of the aforementioned limitations of the Gagne model, including extension to the peripheral phantom axes. Comparison of simulated and measured dose data provides experimental validation of the model, including verification of the superior match to the penumbra provided by the tilted-anode model, as well as the observable effects on the cumulative dose distribution. The initial motivation for the model was to simulate the quasiperiodic dose distribution on the peripheral, phantom axes resulting from a helical scan series in order to facilitate the implementation of an improved method of CT dose measurement utilizing a short ion chamber, as proposed by Dixon [Med. Phys. 30, 1272-1280 (2003)]. A more detailed set of guidelines for implementing such measurements is also presented in this paper. In addition, some fundamental principles governing CT dose which have not previously been clearly enunciated follow from the model, and a fundamental (energy-based) quantity dubbed 'CTDI-aperture' is introduced.

  14. CT in children--dose protection and general considerations when planning a CT in a child.

    PubMed

    Sorantin, E; Weissensteiner, S; Hasenburger, G; Riccabona, M

    2013-07-01

    Today CT represents about 10% of all ionizing radiation based imaging modalities, but delivers more than 50% of the total collective dose for diagnostic imaging. Compared to adults the radiation sensitivity of children is considerable higher than in adults. Additionally children differ from adults--factors like body size, mass, density, proportions as well as metabolism have to be mentioned. Children grow and mature--all this components have to be mapped in examination protocols by Pediatric Radiology. The total dose of a CT examination depends on the settings of several factors such as the scout view, the scan length, exposure settings including automated exposure control, type of scanning (single slice, helical, volume mode), slice thickness, pitch values as well as on image reconstruction parameters. If intravenous contrast media injection is needed bolus tracking or timing represents another source of radiation. The aim of the paper is to present and discuss all aspects of defining a pediatric age and query adapted CT protocol particularly concerning all dose relevant factors in pediatric CT and their adjustment in children. Moreover hints are given concerning optimization of intravenous contrast media injection as well as special (low dose) imaging protocols.

  15. [Ultra-low-dose spiral (helical) CT of the thorax: a filtering technique].

    PubMed

    Nitta, N; Takahashi, M; Murata, K; Mori, M; Shimoyama, K; Mishina, A; Matsuo, H; Morita, R; Sugii, K; Nomura, A

    1996-01-01

    To reduce the radiation dose from spiral (helical) CT, a custom-made aluminium filter was installed in the X-ray tube and a reduction of effective tube current was attempted. A pronounced reduction of effective tube current, namely, 6 and 3 mA, was achieved with 26 and 37 mm thick aluminium filters, respectively. Visualization of normal lung structure was accomplished with both 6 and 3 mA settings. However, images of 3 mA failed to delineate mediastinal structures because of marked beam hardening resulting from the bone structure of the thoracic inlet. Six mA was considered the lowest dose setting of spiral (helical) CT of the thorax that could be used for lung cancer screening.

  16. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients.

    PubMed

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F; Long, Daniel J; Bolch, Wesley E; Liu, Bob; Xu, X George

    2015-07-21

    This paper describes the development and testing of VirtualDose--a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the 'software as a service (SaaS)' delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose's functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT-two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.

  17. Measurement of radiation dose in cerebral CT perfusion study.

    PubMed

    Hirata, Masaaki; Sugawara, Yoshifumi; Fukutomi, Yukimi; Oomoto, Kenji; Murase, Kenya; Miki, Hitoshi; Mochizuki, Teruhito

    2005-03-01

    To evaluate radiation dose in cerebral perfusion studies with a multi-detector row CT (MDCT) scanner on various voltage and current settings by using a human head phantom. Following the CT perfusion study protocol, continuous cine scans (1 sec/rotation x60 sec) consisting of four 5-mm-thick contiguous slices were performed three times at variable tube voltages of 80 kV, 100 kV, 120 kV, and 140 kV with the same tube current setting of 200 mA and on variable current settings of 50 mA, 100 mA, 150 mA, and 200 mA with the same tube voltage of 80 kV. Radiation doses were measured using a total of 41 theroluminescent dosimeters (TLDs) placed in the human head phantom. Thirty-six TLDs were inside and three were on the surface of the slice of the X-ray beam center, and two were placed on the surface 3 cm caudal assuming the lens position. Average radiation doses of surface, inside, and lens increased in proportion to the increases of tube voltage and tube current. The lowest inside dose was 87.6+/-15.3 mGy, and the lowest surface dose was 162.5+/-6.7 mGy at settings of 80 kV and 50 mA. The highest inside dose was 1,591.5+/-179.7 mGy, and the highest surface dose was 2,264.6+/-123.7 mGy at 140 kV-200 mA. At 80 kV-50 mA, the average radiation dose of lens was the lowest at 5.5+/-0.0 mGy. At 140 kV-200 mA the radiation dose of lens was the highest at 127.2+/-0.6 mGy. In cerebral CT perfusion study, radiation dose can vary considerably. Awareness of the patient's radiation dose is recommended.

  18. Attenuation correction of PET cardiac data with low-dose average CT in PET/CT

    SciTech Connect

    Pan Tinsu; Mawlawi, Osama; Luo, Dershan; Liu, Hui H.; Chi Paichun, M.; Mar, Martha V.; Gladish, Gregory; Truong, Mylene; Erasmus, Jeremy Jr.; Liao Zhongxing; Macapinlac, H. A.

    2006-10-15

    We proposed a low-dose average computer tomography (ACT) for attenuation correction (AC) of the PET cardiac data in PET/CT. The ACT was obtained from a cine CT scan of over one breath cycle per couch position while the patient was free breathing. We applied this technique on four patients who underwent tumor imaging with {sup 18}F-FDG in PET/CT, whose PET data showed high uptake of {sup 18}F-FDG in the heart and whose CT and PET data had misregistration. All four patients did not have known myocardiac infarction or ischemia. The patients were injected with 555-740 MBq of {sup 18}F-FDG and scanned 1 h after injection. The helical CT (HCT) data were acquired in 16 s for the coverage of 100 cm. The PET acquisition was 3 min per bed of 15 cm. The duration of cine CT acquisition per 2 cm was 5.9 s. We used a fast gantry rotation cycle time of 0.5 s to minimize motion induced reconstruction artifacts in the cine CT images, which were averaged to become the ACT images for AC of the PET data. The radiation dose was about 5 mGy for 5.9 s cine duration. The selection of 5.9 s was based on our analysis of the respiratory signals of 600 patients; 87% of the patients had average breath cycles of less than 6 s and 90% had standard deviations of less than 1 s in the period of breath cycle. In all four patient studies, registrations between the CT and the PET data were improved. An increase of average uptake in the anterior and the lateral walls up to 48% and a decrease of average uptake in the septal and the inferior walls up to 16% with ACT were observed. We also compared ACT and conventional slow scan CT (SSCT) of 4 s duration in one patient study and found ACT was better than SSCT in depicting average respiratory motion and the SSCT images showed motion-induced reconstruction artifacts. In conclusion, low-dose ACT improved registration of the CT and the PET data in the heart region in our study of four patients. ACT was superior than SSCT for depicting average respiration

  19. Estimating thyroid dose in pediatric CT exams from surface dose measurement

    NASA Astrophysics Data System (ADS)

    Al-Senan, Rani; Mueller, Deborah L.; Hatab, Mustapha R.

    2012-07-01

    The purpose of this study was to investigate the possibility of estimating pediatric thyroid doses from CT using surface neck doses. Optically stimulated luminescence dosimeters were used to measure the neck surface dose of 25 children ranging in ages between one and three years old. The neck circumference for each child was measured. The relationship between obtained surface doses and thyroid dose was studied using acrylic phantoms of various sizes and with holes of different depths. The ratios of hole-to-surface doses were used to convert patients' surface dose to thyroid dose. ImPACT software was utilized to calculate thyroid dose after applying the appropriate age correction factors. A paired t-test was performed to compare thyroid doses from our approach and ImPACT. The ratio of thyroid to surface dose was found to be 1.1. Thyroid doses ranged from 20 to 80 mGy. Comparison showed no statistical significance (p = 0.18). In addition, the average of surface dose variation along the z-axis in helical scans was studied and found to range between 5% (in 10 cm diameter phantom/24 mm collimation/pitch 1.0) and 8% (in 16 cm diameter phantom/12 mm collimation/pitch 0.7). We conclude that surface dose is an acceptable predictor for pediatric thyroid dose from CT. The uncertainty due to surface dose variability may be reduced if narrower collimation is used with a pitch factor close to 1.0. Also, the results did not show any effect of thyroid depth on the measured dose.

  20. Low dose CT perfusion using k-means clustering

    NASA Astrophysics Data System (ADS)

    Pisana, Francesco; Henzler, Thomas; Schönberg, Stefan; Klotz, Ernst; Schmidt, Bernhard; Kachelrieß, Marc

    2016-03-01

    We aim at improving low dose CT perfusion functional parameters maps and CT images quality, preserving quantitative information. In a dynamic CT perfusion dataset, each voxel is measured T times, where T is the number of acquired time points. In this sense, we can think about a voxel as a point in a T-dimensional space, where the coordinates of the voxels would be the values of its time attenuation curve (TAC). Starting from this idea, a k-means algorithm was designed to group voxels in K classes. A modified guided time-intensity profile similarity (gTIPS) filter was implemented and applied only for those voxels belonging to the same class. The approach was tested on a digital brain perfusion phantom as well as on clinical brain and body perfusion datasets, and compared to the original TIPS implementation. The TIPS filter showed the highest CNR improvement, but lowest spatial resolution. gTIPS proved to have the best combination of spatial resolution and CNR improvement for CT images, while k-gTIPS was superior to both gTIPS and TIPS in terms of perfusion maps image quality. We demonstrate k-means clustering analysis can be applied to denoise dynamic CT perfusion data and to improve functional maps. Beside the promising results, this approach has the major benefit of being independent from the perfusion model employed for functional parameters calculation. No similar approaches were found in literature.

  1. Fast reconstruction of low dose proton CT by sinogram interpolation

    NASA Astrophysics Data System (ADS)

    Hansen, David C.; Sangild Sørensen, Thomas; Rit, Simon

    2016-08-01

    Proton computed tomography (CT) has been demonstrated as a promising image modality in particle therapy planning. It can reduce errors in particle range calculations and consequently improve dose calculations. Obtaining a high imaging resolution has traditionally required computationally expensive iterative reconstruction techniques to account for the multiple scattering of the protons. Recently, techniques for direct reconstruction have been developed, but these require a higher imaging dose than the iterative methods. No previous work has compared the image quality of the direct and the iterative methods. In this article, we extend the methodology for direct reconstruction to be applicable for low imaging doses and compare the obtained results with three state-of-the-art iterative algorithms. We find that the direct method yields comparable resolution and image quality to the iterative methods, even at 1 mSv dose levels, while yielding a twentyfold speedup in reconstruction time over previously published iterative algorithms.

  2. Effective dose from cone beam CT examinations in dentistry.

    PubMed

    Roberts, J A; Drage, N A; Davies, J; Thomas, D W

    2009-01-01

    Cone beam CT (CBCT) is becoming an increasingly utilized imaging modality for dental examinations in the UK. Previous studies have presented little information on patient dose for the range of fields of view (FOVs) that can be utilized. The purpose of the study was therefore to calculate the effective dose delivered to the patient during a selection of CBCT examinations performed in dentistry. In particular, the i-CAT CBCT scanner was investigated for several imaging protocols commonly used in clinical practice. A Rando phantom containing thermoluminescent dosemeters was scanned. Using both the 1990 and recently approved 2007 International Commission on Radiological Protection recommended tissue weighting factors, effective doses were calculated. The doses (E(1990), E(2007)) were: full FOV head (92.8 microSv, 206.2 microSv); 13 cm scan of the jaws (39.5 microSv, 133.9 microSv); 6 cm high-resolution mandible (47.2 microSv, 188.5 microSv); 6 cm high-resolution maxilla (18.5 microSv, 93.3 microSv); 6 cm standard mandible (23.9 microSv, 96.2 microSv); and 6 cm standard maxilla (9.7 microSv, 58.9 microSv). The doses from CBCT are low compared with conventional CT but significantly higher than conventional dental radiography techniques.

  3. Performance of an automatic dose control system for CT: anthropomorphic phantom studies.

    PubMed

    Gosch, D; Stumpp, P; Kahn, T; Nagel, H D

    2011-02-01

    To assess the performance and to provide more detailed insight into characteristics and limitations of devices for automatic dose control (ADC) in CT. A comprehensive study on DoseRight 2.0, the ADC system provided by Philips for its Brilliance CT scanners, was conducted with assorted tests using an anthropomorphic phantom that allowed simulation of the operation of the system under almost realistic conditions. The scan protocol settings for the neck, chest and abdomen with pelvis were identical to those applied in the clinical routine. Using the appropriate ADC functionalities, dose reductions equal 40% for the neck, 20% for the chest and 10% for the abdomen with pelvis. Larger dose reductions can be expected for average patients, since their attenuating properties differ significantly from the anthropomorphic phantom. Adverse effects due to increased image noise were only moderate as a consequence of the "adequate noise system" design and the complementary use of adaptive filtration. The results of specific tests also provided deeper insight into the operation of the ADC system that helps to identify the causes of suspected malfunctions and to prevent potential pitfalls. Tests with anthropomorphic phantoms allow verification of the characteristics of devices for ADC in CT under almost realistic conditions. However, differences in phantom shape and material composition require supplementary patient studies on representative patient groups. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Reduction of radiation exposure by lead curtain shielding in dedicated extremity cone beam CT.

    PubMed

    Lee, C-H; Ryu, J H; Lee, Y-H; Yoon, K-H

    2015-06-01

    A dedicated extremity cone beam CT (CBCT) was introduced recently, and is rapidly becoming an attractive modality for extremity imaging. This study aimed to evaluate the effectiveness of a curtain-shaped lead shielding in reducing the exposure of patients to scattered radiation in dedicated extremity CBCT. A dedicated extremity CBCT scanner was used. The lead shielding curtain was 42 × 60 cm with 0.5-mm lead equivalent. Scattered radiation dose from CBCT was measured using thermoluminescence dosimetry chips at 20 points, at different distances and directions from the CT gantry. Two sets of scattered radiation dose measurements were performed before and after installation of curtain-shaped lead shield, and the percentage reduction in dose in air was calculated. Mean radiation exposure dose at measured points was 34.46 ± 48.40 μGy without curtains and 9.67 ± 4.53 μGy with curtains, exhibiting 71.94% reduction (p = 0.000). The use of lead shielding curtains significantly reduced scattered radiation at 0.5, 1.0 and 1.5 m from the CT gantry, with percent reductions of 84.8%, 58.0% and 35.5%, respectively (p = 0.000, 0.000 and 0.002). The percent reduction in the diagonal (+45°, -45°) and vertical forward (0°) directions were 86.3%, 83.1% and 77.7%, respectively, and were statistically significant (p = 0.029, 0.020 and 0.041). Shielding with lead curtains suggests an easy and effective method for reducing patient exposure to radiation in extremity CBCT imaging. Lead shielding curtains are an effective technique to reduce scattered radiation dose in dedicated extremity CBCT, with higher dose reduction closer to the gantry opening.

  5. Measured Head CT/CTA Skin Dose and Intensive Care Unit Patient Cumulative Exposure.

    PubMed

    Nawfel, R D; Young, G S

    2017-03-01

    Estimates of cumulative CT/CTA radiation dose based on volumetric CT dose index have raised concern that neurological intensive care unit patient exposures may reach thresholds for deterministic skin injury. Because the accuracy of volumetric CT dose index for this purpose in unknown, we set out to directly measure head CT and CTA peak skin dose, assess the relationship of volumetric CT dose index to measured peak skin dose, and determine whether multiple CT/CTA exposures in typical patients in the neurological intensive care unit produce cumulative doses approaching or exceeding single-dose deterministic thresholds for skin injury. In a prospective study from 2011-2013, nanoDot optical stimulated luminescence dosimeters were used to measure head CT/CTA peak skin dose in 52 patients (28 female, 24 male; mean age, 63 years) divided equally between 2 CT scanners. Volumetric CT dose index and dose-length product were recorded for each examination. Peak skin dose was also measured on an acrylic skull phantom in each scanner. A 2-tailed, unpaired t test was used to compare mean patient skin doses between the 2 scanners. The measured peak skin doses were then used to calculate cumulative peak skin dose in 4 typical patients in intensive care units who received multiple CT/CTA scans. Head CT/CTA peak skin dose agreed between scanners in patients and phantoms: (scanner 1 CT/CTA: patients, 39.2 ± 3.7 mGy and 98.9 ± 5.3 mGy, respectively, versus phantom, 40.0 mGy and 105.4 mGy, respectively; scanner 2 CT/CTA: patients, 42.9 ± 9.4 mGy and 98.8 ± 7.4 mGy, respectively, versus phantom, 37.6 mGy and 95.2 mGy, respectively). Volumetric CT dose index overestimated peak skin dose by a factor of 1.4-1.9 depending on examination and CT scanner. Cumulative doses in 4 patients in the intensive care unit estimated from measured CT/CTA peak skin dose ranged from 1.9-4.5 Gy. Directly measured radiation skin doses from head CT/CTA patient examinations are substantially lower than

  6. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations.

    PubMed

    Montes, Carlos; Tamayo, Pilar; Hernandez, Jorge; Gomez-Caminero, Felipe; García, Sofia; Martín, Carlos; Rosero, Angela

    2013-08-01

    Hybrid imaging, such as SPECT/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose.

  7. Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study

    PubMed Central

    Kaup, Moritz; Gruber-Rouh, Tatjana; Scholtz, Jan E; Albrecht, Moritz H; Bucher, Andreas; Frellesen, Claudia; Vogl, Thomas J

    2016-01-01

    Background Computed tomography (CT) low-dose (LD) imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems. Purpose To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA). Material and Methods CTPA scans from 60 prospectively randomized patients (28 men, 32 women) were examined in this study on a 15-year-old 16-slice CT scanner system. Standard CT (SD) settings were 100 kV and 150 mAs, LD settings were 100 kV and 50 mAs. Attenuation of the pulmonary trunk, various anatomic landmarks, and image noise were quantitatively measured; contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR) were calculated. Three independent blinded radiologists subjectively rated each image series using a 5-point grading scale. Results CT dose index (CTDI) in the LD series was 66.46% lower compared to the SD settings (2.49 ± 0.55 mGy versus 7.42 ± 1.17 mGy). Attenuation of the pulmonary trunk showed similar results for both series (SD 409.55 ± 91.04 HU; LD 380.43 HU ± 93.11 HU; P = 0.768). Subjective image analysis showed no significant differences between SD and LD settings regarding the suitability for detection of central and peripheral PE (central SD/LD, 4.88; intra-class correlation coefficients [ICC], 0.894/4.83; ICC, 0.745; peripheral SD/LD, 4.70; ICC, 0.943/4.57; ICC, 0.919; all P > 0.4). Conclusion The LD protocol, on a 15-year-old CT scanner system without current high-end hardware or post-processing tools, led to a dose reduction of approximately 67% with similar subjective image quality and delineation of central and peripheral pulmonary arteries. PMID:28286671

  8. Dose reduction in molecular breast imaging

    NASA Astrophysics Data System (ADS)

    Wagenaar, Douglas J.; Chowdhury, Samir; Hugg, James W.; Moats, Rex A.; Patt, Bradley E.

    2011-10-01

    Molecular Breast Imaging (MBI) is the imaging of radiolabeled drugs, cells, or nanoparticles for breast cancer detection, diagnosis, and treatment. Screening of broad populations of women for breast cancer with mammography has been augmented by the emergence of breast MRI in screening of women at high risk for breast cancer. Screening MBI may benefit the sub-population of women with dense breast tissue that obscures small tumors in mammography. Dedicated breast imaging equipment is necessary to enable detection of early-stage tumors less than 1 cm in size. Recent progress in the development of these instruments is reviewed. Pixellated CZT for single photon MBI imaging of 99mTc-sestamibi gives high detection sensitivity for early-stage tumors. The use of registered collimators in a near-field geometry gives significantly higher detection efficiency - a factor of 3.6-, which translates into an equivalent dose reduction factor given the same acquisition time. The radiation dose in the current MBI procedure has been reduced to the level of a four-view digital mammography study. In addition to screening of selected sub-populations, reduced MBI dose allows for dual-isotope, treatment planning, and repeated therapy assessment studies in the era of molecular medicine guided by quantitative molecular imaging.

  9. Lateral topography for reducing effective dose in low-dose chest CT.

    PubMed

    Bang, Dong-Ho; Lim, Daekeon; Hwang, Wi-Sub; Park, Seong-Hoon; Jeong, Ok-man; Kang, Kyung Wook; Kang, Hohyung

    2013-06-01

    The purposes of this study were to assess radiation exposure during low-dose chest CT by using lateral topography and to compare the lateral topographic findings with findings obtained with anteroposterior topography alone and anteroposterior and lateral topography combined. From November 2011 to February 2012, 210 male subjects were enrolled in the study. Age, weight, and height of the men were recorded. All subjects were placed into one of three subgroups based on the type of topographic image obtained: anteroposterior topography, lateral topography, and both anteroposterior and lateral topography. Imaging was performed with a 128-MDCT scanner. CT, except for topography, was the same for all subjects. A radiologist analyzed each image, recorded scan length, checked for any insufficiencies in the FOV, and calculated the effective radiation dose. One-way analysis of variance and multiple comparisons were used to compare the effective radiation exposure and scan length between groups. The mean scan length in the anteroposterior topography group was significantly greater than that of the lateral topography group and the combined anteroposterior and lateral topography group (p < 0.001). The mean effective radiation dose for the lateral topography group (0.735 ± 0.033 mSv) was significantly lower than that for the anteroposterior topography group (0.763 ± 0.038 mSv) and the combined anteroposterior and lateral topography group (0.773 ± 0.038) (p < 0.001). Lateral topographic low-dose CT was associated with a lower effective radiation dose and scan length than either anteroposterior topographic low-dose chest CT or low-dose chest CT with both anteroposterior and lateral topograms.

  10. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients

    NASA Astrophysics Data System (ADS)

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F.; Long, Daniel J.; Bolch, Wesley E.; Liu, Bob; Xu, X. George

    2015-07-01

    This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.

  11. Pediatric organ dose measurements in axial and helical multislice CT

    SciTech Connect

    McDermott, Alanna; White, R. Allen; Mc-Nitt-Gray, Mike; Angel, Erin; Cody, Dianna

    2009-05-15

    An anthropomorphic pediatric phantom (5-yr-old equivalent) was used to determine organ doses at specific surface and internal locations resulting from computed tomography (CT) scans. This phantom contains four different tissue-equivalent materials: Soft tissue, bone, brain, and lung. It was imaged on a 64-channel CT scanner with three head protocols (one contiguous axial scan and two helical scans [pitch=0.516 and 0.984]) and four chest protocols (one contiguous axial scan and three helical scans [pitch=0.516, 0.984, and 1.375]). Effective mA s [=(tube currentxrotation time)/pitch] was kept nearly constant at 200 effective mA s for head and 290 effective mA s for chest protocols. Dose measurements were acquired using thermoluminescent dosimeter powder in capsules placed at locations internal to the phantom and on the phantom surface. The organs of interest were the brain, both eyes, thyroid, sternum, both breasts, and both lungs. The organ dose measurements from helical scans were lower than for contiguous axial scans by 0% to 25% even after adjusting for equivalent effective mA s. There was no significant difference (p>0.05) in organ dose values between the 0.516 and 0.984 pitch values for both head and chest scans. The chest organ dose measurements obtained at a pitch of 1.375 were significantly higher than the dose values obtained at the other helical pitches used for chest scans (p<0.05). This difference was attributed to the automatic selection of the large focal spot due to a higher tube current value. These findings suggest that there may be a previously unsuspected radiation dose benefit associated with the use of helical scan mode during computed tomography scanning.

  12. Techniques and tactics for optimizing CT dose in adults and children: state of the art and future advances.

    PubMed

    Lambert, Jack; MacKenzie, John D; Cody, Dianna D; Gould, Robert

    2014-03-01

    With growing concern over radiation exposure from CT, dose reduction and optimization have become important considerations. Many protocol factors and CT technologies influence this dose reduction effort, and as such, users should maintain a working knowledge of developments in the field. Individual patient factors and scanner-specific details also require care and expertise, which are vital to the success of any dose reduction effort. The authors review the content of the Virtual Symposium on Radiation Safety in Computed Tomography (University of California Dose Optimization and Standardization Endeavor), specifically that pertaining to the more practical aspects of dose optimization. These range from prescan tips to postscan factors, as well as protocol definition itself. Topics discussed include localizer radiograph acquisition, tube current modulation, reconstruction methods, and pediatric considerations, with the content biased toward a CT technologist or protocol manager. Near-term innovations, including new iterative reconstruction methods, tube potential modulation, and dual-energy CT, are presented, and their capability for dose reduction is briefly discussed. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of image and dose according to I-dose technique when performing a CT scan

    NASA Astrophysics Data System (ADS)

    Ryu, S. W.; Lee, H. K.; Cho, J. H.

    2015-06-01

    In this study, we applied the iterative reconstruction technique to improve image quality (I-dose) and evaluated its usability by analyzing the quality of the resulting image and evaluating the dose. To perform the scans, we fixed the uniform module (CTP 486's section) 4 on the table of the computed tomography (CT) device with the American association of physicists in medicine (AAPM) phantom and located it in the center where the X-rays could be generated by using a razor beam. Then, we set up the conditions of 120 kilovoltage peak (kVp), 150 milliampere second (mAs), collimation 4 × 0.625 mm, and a standard YA (Y-Sharp) filter. Next, we formed two groups: Group A in which I-dose was not applied and Group B in which I-dose was applied. According to the rod in the middle, after fixing the location of (A) at 12 o'clock, (B) at 3 o'clock, (C) at 6 o'clock, and (D) at 9 o'clock to evaluate the image quality, the CT number was measured and the noise level was analyzed. Using the AAPM phantom with doses of 50, 100, 200, 250, and 300 mAs by 80, 100, and 120 kVp, a dose analysis was performed. After scanning, the CT numbers and noise level were measured 20 times as a function of the I-dose levels (1-7). After applying I-dose at 6, 9, 12, and 3 o'clock, when a higher I-dose was applied, a lower noise level was measured. As a result, it was found that when applying I-dose to the AAPM phantom, the higher the level of I-dose, the lower the level of noise. When applying I-dose, the dose can be reduced by 60%. When I-dose is applied when taking CT scans in a clinical study, it is possible to lower the dose and lower the noise level.

  14. Estimating radiation dose to organs of patients undergoing conventional and novel multidetector CT exams using Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Angel, Erin

    Advances in Computed Tomography (CT) technology have led to an increase in the modality's diagnostic capabilities and therefore its utilization, which has in turn led to an increase in radiation exposure to the patient population. As a result, CT imaging currently constitutes approximately half of the collective exposure to ionizing radiation from medical procedures. In order to understand the radiation risk, it is necessary to estimate the radiation doses absorbed by patients undergoing CT imaging. The most widely accepted risk models are based on radiosensitive organ dose as opposed to whole body dose. In this research, radiosensitive organ dose was estimated using Monte Carlo based simulations incorporating detailed multidetector CT (MDCT) scanner models, specific scan protocols, and using patient models based on accurate patient anatomy and representing a range of patient sizes. Organ dose estimates were estimated for clinical MDCT exam protocols which pose a specific concern for radiosensitive organs or regions. These dose estimates include estimation of fetal dose for pregnant patients undergoing abdomen pelvis CT exams or undergoing exams to diagnose pulmonary embolism and venous thromboembolism. Breast and lung dose were estimated for patients undergoing coronary CTA imaging, conventional fixed tube current chest CT, and conventional tube current modulated (TCM) chest CT exams. The correlation of organ dose with patient size was quantified for pregnant patients undergoing abdomen/pelvis exams and for all breast and lung dose estimates presented. Novel dose reduction techniques were developed that incorporate organ location and are specifically designed to reduce close to radiosensitive organs during CT acquisition. A generalizable model was created for simulating conventional and novel attenuation-based TCM algorithms which can be used in simulations estimating organ dose for any patient model. The generalizable model is a significant contribution of this

  15. Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction

    PubMed Central

    Eck, Brendan L.; Fahmi, Rachid; Brown, Kevin M.; Zabic, Stanislav; Raihani, Nilgoun; Miao, Jun; Wilson, David L.

    2015-01-01

    model complexity according to AICc. With parameters fixed, the model reasonably predicted detectability of human observers in blended FBP-IMR images. Semianalytic internal noise computation gave results equivalent to Monte Carlo, greatly speeding parameter estimation. Using Model-k4, the authors found an average detectability improvement of 2.7 ± 0.4 times that of FBP. IMR showed greater improvements in detectability with larger signals and relatively consistent improvements across signal contrast and x-ray dose. In the phantom tested, Model-k4 predicted an 82% dose reduction compared to FBP, verified with physical CT scans at 80% reduced dose. Conclusions: IMR improves detectability over FBP and may enable significant dose reductions. A channelized Hotelling observer with internal noise proportional to channel output standard deviation agreed well with human observers across a wide range of variables, even across reconstructions with drastically different image characteristics. Utility of the model observer was demonstrated by predicting the effect of image processing (blending), analyzing detectability improvements with IMR across dose, size, and contrast, and in guiding real CT scan dose reduction experiments. Such a model observer can be applied in optimizing parameters in advanced iterative reconstruction algorithms as well as guiding dose reduction protocols in physical CT experiments. PMID:26429285

  16. Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction

    SciTech Connect

    Eck, Brendan L.; Fahmi, Rachid; Miao, Jun; Brown, Kevin M.; Zabic, Stanislav; Raihani, Nilgoun; Wilson, David L.

    2015-10-15

    and model complexity according to AIC{sub c}. With parameters fixed, the model reasonably predicted detectability of human observers in blended FBP-IMR images. Semianalytic internal noise computation gave results equivalent to Monte Carlo, greatly speeding parameter estimation. Using Model-k4, the authors found an average detectability improvement of 2.7 ± 0.4 times that of FBP. IMR showed greater improvements in detectability with larger signals and relatively consistent improvements across signal contrast and x-ray dose. In the phantom tested, Model-k4 predicted an 82% dose reduction compared to FBP, verified with physical CT scans at 80% reduced dose. Conclusions: IMR improves detectability over FBP and may enable significant dose reductions. A channelized Hotelling observer with internal noise proportional to channel output standard deviation agreed well with human observers across a wide range of variables, even across reconstructions with drastically different image characteristics. Utility of the model observer was demonstrated by predicting the effect of image processing (blending), analyzing detectability improvements with IMR across dose, size, and contrast, and in guiding real CT scan dose reduction experiments. Such a model observer can be applied in optimizing parameters in advanced iterative reconstruction algorithms as well as guiding dose reduction protocols in physical CT experiments.

  17. Identifying Institutional Diagnostic Reference Levels for CT with Radiation Dose Index Monitoring Software.

    PubMed

    MacGregor, Kate; Li, Iris; Dowdell, Timothy; Gray, Bruce G

    2015-08-01

    To retrospectively evaluate radiation optimization efforts over 4 years for three computed tomography (CT) protocols and to determine institutional (local) diagnostic reference levels for prospective tracking by using automated radiation dose index monitoring software. Approval for this retrospective observational study was obtained from the hospital research ethics board, and the need to obtain informed consent was waived. The study followed a 48-month radiation dose optimization effort in a large academic inner-city trauma and quaternary referral center. Exposure according to equipment, protocol, and year (2010-2013) for adult patients was determined for routine unenhanced head CT examinations, CT pulmonary angiography examinations, and CT examinations for renal colic. Mean exposure (as volume CT dose index [CTDIvol] and dose-length product [DLP]) was averaged to establish local diagnostic reference levels. Means and 75th percentiles for 2013 were compared with findings from surveys in Canada and diagnostic reference levels for similar protocol types internationally. Student t tests were performed to assess significance between annual means, and χ(2) tests were performed for changes in categoric variables. There were 36 996 examinations in 25 234 patients. There was an average exposure reduction of 22% for CTDIvol and 13% for DLP from 2010 to 2013. In 2013, mean CTDIvol for routine head examinations was 50.8 mGy ± 3.7 (standard deviation), 11.8 mGy ± 5.6 for CT pulmonary angiography examinations, and 10.2 mGy ± 4.2 for renal colic CT examinations, while mean DLP was 805.7 mGy · cm ± 124.3, 432.8 mGy-cm ± 219.9, and 469.4 mGy · cm ± 209.2, respectively. The mean CTDIvol and DLP in 2013 were at or close to identified reference values; however, additional optimization is required to reach "as low as reasonably achievable" values for all examinations. Automated methods of radiation dose data collection permit a detailed analysis of radiation dose according

  18. Algorithm-enabled Low-dose Micro-CT Imaging

    PubMed Central

    Han, Xiao; Bian, Junguo; Eaker, Diane R.; Kline, Timothy L.; Sidky, Emil Y.; Ritman, Erik L.; Pan, Xiaochuan

    2013-01-01

    Micro-CT is an important tool in biomedical research and preclinical applications that can provide visual inspection of and quantitative information about imaged small animals and biological samples such as vasculature specimens. Currently, micro-CT imaging uses projection data acquired at a large number (300 – 1000) of views, which can limit system throughput and potentially degrade image quality due to radiation-induced deformation or damage to the small animal or specimen. In this work, we have investigated low-dose micro-CT and its application to specimen imaging from substantially reduced projection data by using a recently developed algorithm, referred to as the adaptive-steepest-descent-projection-onto-convex-sets (ASD-POCS) algorithm, which reconstructs an image through minimizing the image total-variation and enforcing data constraints. To validate and evaluate the performance of the ASD-POCS algorithm, we carried out quantitative evaluation studies in a number of tasks of practical interest in imaging of specimens of real animal organs. The results show that the ASD-POCS algorithm can yield images with quality comparable to that obtained with existing algorithms, while using one-sixth to one quarter of the 361-view data currently used in typical micro-CT specimen imaging. PMID:20977983

  19. Low-dose and scatter-free cone-beam CT imaging: a preliminary study

    NASA Astrophysics Data System (ADS)

    Dong, Xue; Jia, Xun; Niu, Tianye; Zhu, Lei

    2012-03-01

    Clinical applications of CBCT imaging are still limited by excessive imaging dose from repeated scans and poor image quality mainly due to scatter contamination. Compressed sensing (CS) reconstruction algorithms have shown promises in recovering faithful signals from low-dose projection data, but do not serve well the needs of accurate CBCT imaging if effective scatter correction is not in place. Scatter can be accurately measured and removed using measurement-based methods. However, in conventional FDK reconstruction, these approaches are considered unpractical since they require multiple scans or moving the beam blocker during the data acquisition to compensate for the inevitable primary loss. In this work, we combine the measurement-based scatter correction and CS-based iterative reconstruction algorithm, such that scatter-free images can be obtained from low-dose data. We lower the CBCT dose by reducing the projection number and inserting lead strips between the x-ray source and the object. The insertion of lead strips also enables scatter measurement on the measured samples inside the strip shadows. CS-based iterative reconstruction is finally carried out to obtain scatter-free and low-dose CBCT images. Simulation studies are designed to optimize the lead strip geometry for a certain dose reduction ratio. After optimization, our approach reduces the CT number error from over 220HU to below 5HU on the Shepp-Logan phantom, with a dose reduction of ~80%. With the same dose reduction and the optimized method parameters, the CT number error is reduced from 242HU to 20HU in the selected region of interest on Catphan©600 phantom.

  20. Statistical image reconstruction for low-dose CT using nonlocal means-based regularization.

    PubMed

    Zhang, Hao; Ma, Jianhua; Wang, Jing; Liu, Yan; Lu, Hongbing; Liang, Zhengrong

    2014-09-01

    Low-dose computed tomography (CT) imaging without sacrifice of clinical tasks is desirable due to the growing concerns about excessive radiation exposure to the patients. One common strategy to achieve low-dose CT imaging is to lower the milliampere-second (mAs) setting in data scanning protocol. However, the reconstructed CT images by the conventional filtered back-projection (FBP) method from the low-mAs acquisitions may be severely degraded due to the excessive noise. Statistical image reconstruction (SIR) methods have shown potentials to significantly improve the reconstructed image quality from the low-mAs acquisitions, wherein the regularization plays a critical role and an established family of regularizations is based on the Markov random field (MRF) model. Inspired by the success of nonlocal means (NLM) in image processing applications, in this work, we propose to explore the NLM-based regularization for SIR to reconstruct low-dose CT images from low-mAs acquisitions. Experimental results with both digital and physical phantoms consistently demonstrated that SIR with the NLM-based regularization can achieve more gains than SIR with the well-known Gaussian MRF regularization or the generalized Gaussian MRF regularization and the conventional FBP method, in terms of image noise reduction and resolution preservation.

  1. Statistical image reconstruction for low-dose CT using nonlocal means-based regularization

    PubMed Central

    Zhang, Hao; Ma, Jianhua; Wang, Jing; Liu, Yan; Lu, Hongbing

    2014-01-01

    Low-dose computed tomography (CT) imaging without sacrifice of clinical tasks is desirable due to the growing concerns about excessive radiation exposure to the patients. One common strategy to achieve low-dose CT imaging is to lower the milliampere-second (mAs) setting in data scanning protocol. However, the reconstructed CT images by the conventional filtered back-projection (FBP) method from the low-mAs acquisitions may be severely degraded due to the excessive noise. Statistical image reconstruction (SIR) methods have shown potentials to significantly improve the reconstructed image quality from the low-mAs acquisitions, wherein the regularization plays a critical role and an established family of regularizations is based on the Markov random field (MRF) model. Inspired by the success of nonlocal means (NLM) in image processing applications, in this work, we propose to explore the NLM-based regularization for SIR to reconstruct low-dose CT images from low-mAs acquisitions. Experimental results with both digital and physical phantoms consistently demonstrated that SIR with the NLM-based regularization can achieve more gains than SIR with the well-known Gaussian MRF regularization or the generalized Gaussian MRF regularization and the conventional FBP method, in terms of image noise reduction and resolution preservation. PMID:24881498

  2. 3D Dose Verification Using Tomotherapy CT Detector Array

    SciTech Connect

    Sheng Ke; Jones, Ryan; Yang Wensha; Saraiya, Siddharth; Schneider, Bernard; Chen Quan; Sobering, Geoff; Olivera, Gustavo; Read, Paul

    2012-02-01

    Purpose: To evaluate a three-dimensional dose verification method based on the exit dose using the onboard detector of tomotherapy. Methods and Materials: The study included 347 treatment fractions from 24 patients, including 10 prostate, 5 head and neck (HN), and 9 spinal stereotactic body radiation therapy (SBRT) cases. Detector sonograms were retrieved and back-projected to calculate entrance fluence, which was then forward-projected on the CT images to calculate the verification dose, which was compared with ion chamber and film measurement in the QA plans and with the planning dose in patient plans. Results: Root mean square (RMS) errors of 2.0%, 2.2%, and 2.0% were observed comparing the dose verification (DV) and the ion chamber measured point dose in the phantom plans for HN, prostate, and spinal SBRT patients, respectively. When cumulative dose in the entire treatment is considered, for HN patients, the error of the mean dose to the planning target volume (PTV) varied from 1.47% to 5.62% with a RMS error of 3.55%. For prostate patients, the error of the mean dose to the prostate target volume varied from -5.11% to 3.29%, with a RMS error of 2.49%. The RMS error of maximum doses to the bladder and the rectum were 2.34% (-4.17% to 2.61%) and 2.64% (-4.54% to 3.94%), respectively. For the nine spinal SBRT patients, the RMS error of the minimum dose to the PTV was 2.43% (-5.39% to 2.48%). The RMS error of maximum dose to the spinal cord was 1.05% (-2.86% to 0.89%). Conclusions: An excellent agreement was observed between the measurement and the verification dose. In the patient treatments, the agreement in doses to the majority of PTVs and organs at risk is within 5% for the cumulative treatment course doses. The dosimetric error strongly depends on the error in multileaf collimator leaf opening time with a sensitivity correlating to the gantry rotation period.

  3. Pediatric cardiac-gated CT angiography: assessment of radiation dose.

    PubMed

    Hollingsworth, Caroline L; Yoshizumi, Terry T; Frush, Donald P; Chan, Frandics P; Toncheva, Greta; Nguyen, Giao; Lowry, Carolyn R; Hurwitz, Lynne M

    2007-07-01

    The purpose of our study was to determine a dose range for cardiac-gated CT angiography (CTA) in children. ECG-gated cardiac CTA simulating scanning of the heart was performed on an anthropomorphic phantom of a 5-year-old child on a 16-MDCT scanner using variable parameters (small field of view; 16 x 0.625 mm configuration; 0.5-second gantry cycle time; 0.275 pitch; 120 kVp at 110, 220, and 330 mA; and 80 kVp at 385 mA). Metal oxide semiconductor field effect transistor (MOSFET) technology measured 20 organ doses. Effective dose calculated using the dose-length product (DLP) was compared with effective dose determined from measured absorbed organ doses. Highest organ doses included breast (3.5-12.6 cGy), lung (3.3-12.1 cGy), and bone marrow (1.7-7.6 cGy). The 80 kVp/385 mA examination produced lower radiation doses to all organs than the 120 kVp/220 mA examination. MOSFET effective doses (+/- SD) were as follows: 110 mA: 7.4 mSv (+/- 0.6 mSv), 220 mA: 17.2 mSv (+/- 0.3 mSv), 330 mA: 25.7 mSv (+/- 0.3 mSv), 80 kVp/385 mA: 10.6 mSv (+/- 0.2 mSv). DLP effective doses for diagnostic runs were as follows: 110 mA: 8.7 mSv, 220 mA: 19 mSv, 330 mA: 28 mSv, 80 kVp/385 mA: 12 mSv. DLP effective doses exceeded MOSFET effective doses by 9.7-17.2%. Radiation doses for a 5-year-old during cardiac-gated CTA vary greatly depending on parameters. Organ doses can be high; the effective dose may reach 28.4 mSv. Further work, including determination of size-appropriate mA and image quality, is important before routine use of this technique in children.

  4. A Survey of Pediatric CT Protocols and Radiation Doses in South Korean Hospitals to Optimize the Radiation Dose for Pediatric CT Scanning.

    PubMed

    Hwang, Jae-Yeon; Do, Kyung-Hyun; Yang, Dong Hyun; Cho, Young Ah; Yoon, Hye-Kyung; Lee, Jin Seong; Koo, Hyun Jung

    2015-12-01

    Children are at greater risk of radiation exposure than adults because the rapidly dividing cells of children tend to be more radiosensitive and they have a longer expected life time in which to develop potential radiation injury. Some studies have surveyed computed tomography (CT) radiation doses and several studies have established diagnostic reference levels according to patient age or body size; however, no survey of CT radiation doses with a large number of patients has yet been carried out in South Korea. The aim of the present study was to investigate the radiation dose in pediatric CT examinations performed throughout South Korea. From 512 CT (222 brain CT, 105 chest CT, and 185 abdominopelvic CT) scans that were referred to our tertiary hospital, a dose report sheet was available for retrospective analysis of CT scan protocols and dose, including the volumetric CT dose index (CTDIvol), dose-length product (DLP), effective dose, and size-specific dose estimates (SSDE). At 55.2%, multiphase CT was the most frequently performed protocol for abdominopelvic CT. Tube current modulation was applied most often in abdominopelvic CT and chest CT, accounting for 70.1% and 62.7%, respectively. Regarding the CT dose, the interquartile ranges of the CTDIvol were 11.1 to 22.5 (newborns), 16.6 to 39.1 (≤1 year), 14.6 to 41.7 (2-5 years), 23.5 to 44.1 (6-10 years), and 31.4 to 55.3 (≤15 years) for brain CT; 1.3 to 5.7 (≤1 year), 3.9 to 6.8 (2-5 years), 3.9 to 9.3 (6-10 years), and 7.7 to 13.8 (≤15 years) for chest CT; and 4.0 to 7.5 (≤1 year), 4.2 to 8.9 (2-5 years), 5.7 to 12.4 (6-10 years), and 7.6 to 16.6 (≤15 years) for abdominopelvic CT. The SSDE and CTDIvol were well correlated for patients <5 years old, whereas the CTDIvol was lower in patients ≥6 years old. Our study describes the various parameters and dosimetry metrics of pediatric CT in South Korea. The CTDIvol, DLP, and effective dose were generally lower than in German and UK surveys, except in

  5. Sinogram restoration for ultra-low-dose x-ray multi-slice helical CT by nonparametric regression

    NASA Astrophysics Data System (ADS)

    Jiang, Lu; Siddiqui, Khan; Zhu, Bin; Tao, Yang; Siegel, Eliot

    2007-03-01

    During the last decade, x-ray computed tomography (CT) has been applied to screen large asymptomatic smoking and nonsmoking populations for early lung cancer detection. Because a larger population will be involved in such screening exams, more and more attention has been paid to studying low-dose, even ultra-low-dose x-ray CT. However, reducing CT radiation exposure will increase noise level in the sinogram, thereby degrading the quality of reconstructed CT images as well as causing more streak artifacts near the apices of the lung. Thus, how to reduce the noise levels and streak artifacts in the low-dose CT images is becoming a meaningful topic. Since multi-slice helical CT has replaced conventional stop-and-shoot CT in many clinical applications, this research mainly focused on the noise reduction issue in multi-slice helical CT. The experiment data were provided by Siemens SOMATOM Sensation 16-Slice helical CT. It included both conventional CT data acquired under 120 kvp voltage and 119 mA current and ultra-low-dose CT data acquired under 120 kvp and 10 mA protocols. All other settings are the same as that of conventional CT. In this paper, a nonparametric smoothing method with thin plate smoothing splines and the roughness penalty was proposed to restore the ultra-low-dose CT raw data. Each projection frame was firstly divided into blocks, and then the 2D data in each block was fitted to a thin-plate smoothing splines' surface via minimizing a roughness-penalized least squares objective function. By doing so, the noise in each ultra-low-dose CT projection was reduced by leveraging the information contained not only within each individual projection profile, but also among nearby profiles. Finally the restored ultra-low-dose projection data were fed into standard filtered back projection (FBP) algorithm to reconstruct CT images. The rebuilt results as well as the comparison between proposed approach and traditional method were given in the results and

  6. Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD).

    PubMed

    Hui, Peter K T; Goo, Hyun Woo; Du, Jing; Ip, Janice J K; Kanzaki, Suzu; Kim, Young Jin; Kritsaneepaiboon, Supika; Lilyasari, Oktavia; Siripornpitak, Suvipaporn

    2017-07-01

    With incremental utilization of pediatric cardiac CT in congenital heart disease, it is imperative to define its current radiation dose levels in clinical practice in order to help imagers optimize CT protocols, particularly in Asia and other developing countries where CT physicists are not readily available. To evaluate current radiation dose levels and influencing factors in cardiac CT in children with congenital heart disease in Asia by conducting a retrospective multi-center, multi-vendor study. We included 1,043 pediatric cardiac CT examinations performed in 8 centers between January 2014 and December 2014 to evaluate congenital heart disease. In five weight groups, we calculated radiation dose metrics including volume CT dose index, size-specific dose estimate, dose-length product and effective dose. Age at CT exam, gender, tube voltage, scan mode, CT indication and image reconstruction algorithm were analyzed to learn whether they influenced CT radiation dose. Volume CT dose index, size-specific dose estimate, dose-length product and effective dose of pediatric cardiac CT showed variations in the range of 4.3-23.8 mGy, 4.9-17.6 mGy, 55.8-501.3 mGy∙cm and 1.5-3.2 mSv, respectively, within five weight groups. Gender, tube voltage, scan mode and cardiac function assessment significantly influenced CT radiation dose. This multi-center, multi-vendor study demonstrated variations in radiation dose metrics of pediatric cardiac CT reflecting current practice in Asia. Gender, tube voltage, scan mode and cardiac function assessment should be considered as essential radiation dose-influencing factors in developing optimal pediatric cardiac CT protocols.

  7. Concepts for dose determination in flat-detector CT

    NASA Astrophysics Data System (ADS)

    Kyriakou, Yiannis; Deak, Paul; Langner, Oliver; Kalender, Willi A.

    2008-07-01

    Flat-detector computed tomography (FD-CT) scanners provide large irradiation fields of typically 200 mm in the cranio-caudal direction. In consequence, dose assessment according to the current definition of the computed tomography dose index CTDIL=100 mm, where L is the integration length, would demand larger ionization chambers and phantoms which do not appear practical. We investigated the usefulness of the CTDI concept and practical dosimetry approaches for FD-CT by measurements and Monte Carlo (MC) simulations. An MC simulation tool (ImpactMC, VAMP GmbH, Erlangen, Germany) was used to assess the dose characteristics and was calibrated with measurements of air kerma. For validation purposes measurements were performed on an Axiom Artis C-arm system (Siemens Medical Solutions, Forchheim, Germany) equipped with a flat detector of 40 cm × 30 cm. The dose was assessed for 70 kV and 125 kV in cylindrical PMMA phantoms of 160 mm and 320 mm diameter with a varying phantom length from 150 to 900 mm. MC simulation results were compared to the values obtained with a calibrated ionization chambers of 100 mm and 250 mm length and to thermoluminesence (TLD) dose profiles. The MCs simulations were used to calculate the efficiency of the CTDIL determination with respect to the desired CTDI∞. Both the MC simulation results and the dose distributions obtained by MC simulation were in very good agreement with the CTDI measurements and with the reference TLD profiles, respectively, to within 5%. Standard CTDI phantoms which have a z-extent of 150 mm underestimate the dose at the center by up to 55%, whereas a z-extent of >=600 mm appears to be sufficient for FD-CT; the baseline value of the respective profile was within 1% to the reference baseline. As expected, the measurements with ionization chambers of 100 mm and 250 mm offer a limited accuracy, whereas an increased integration length of >=600 mm appeared to be necessary to approximate CTDI∞ in within 1%. MC simulations

  8. Radiation Doses of Various CT Protocols: a Multicenter Longitudinal Observation Study

    PubMed Central

    2016-01-01

    Emerging concerns regarding the hazard from medical radiation including CT examinations has been suggested. The purpose of this study was to observe the longitudinal changes of CT radiation doses of various CT protocols and to estimate the long-term efforts of supervising radiologists to reduce medical radiation. Radiation dose data from 11 representative CT protocols were collected from 12 hospitals. Attending radiologists had collected CT radiation dose data in two time points, 2007 and 2010. They collected the volume CT dose index (CTDIvol) of each phase, number of phases, dose length product (DLP) of each phase, and types of scanned CT machines. From the collected data, total DLP and effective dose (ED) were calculated. CTDIvol, total DLP, and ED of 2007 and 2010 were compared according to CT protocols, CT machine type, and hospital. During the three years, CTDIvol had significantly decreased, except for dynamic CT of the liver. Total DLP and ED were significantly decreased in all 11 protocols. The decrement was more evident in newer CT scanners. However, there was substantial variability of changes of ED during the three years according to hospitals. Although there was variability according to protocols, machines, and hospital, CT radiation doses were decreased during the 3 years. This study showed the effects of decreased CT radiation dose by efforts of radiologists and medical society. PMID:26908984

  9. Dose reduction potential of iterative reconstruction algorithms in neck CTA-a simulation study.

    PubMed

    Ellmann, Stephan; Kammerer, Ferdinand; Allmendinger, Thomas; Brand, Michael; Janka, Rolf; Hammon, Matthias; Lell, Michael M; Uder, Michael; Kramer, Manuel

    2016-10-01

    This study aimed to determine the degree of radiation dose reduction in neck CT angiography (CTA) achievable with Sinogram-affirmed iterative reconstruction (SAFIRE) algorithms. 10 consecutive patients scheduled for neck CTA were included in this study. CTA images of the external carotid arteries either were reconstructed with filtered back projection (FBP) at full radiation dose level or underwent simulated dose reduction by proprietary reconstruction software. The dose-reduced images were reconstructed using either SAFIRE 3 or SAFIRE 5 and compared with full-dose FBP images in terms of vessel definition. 5 observers performed a total of 3000 pairwise comparisons. SAFIRE allowed substantial radiation dose reductions in neck CTA while maintaining vessel definition. The possible levels of radiation dose reduction ranged from approximately 34 to approximately 90% and depended on the SAFIRE algorithm strength and the size of the vessel of interest. In general, larger vessels permitted higher degrees of radiation dose reduction, especially with higher SAFIRE strength levels. With small vessels, the superiority of SAFIRE 5 over SAFIRE 3 was lost. Neck CTA can be performed with substantially less radiation dose when SAFIRE is applied. The exact degree of radiation dose reduction should be adapted to the clinical question, in particular to the smallest vessel needing excellent definition.

  10. Reducing absorbed dose to eye lenses in head CT examinations: the effect of bismuth shielding.

    PubMed

    Ciarmatori, Alberto; Nocetti, L; Mistretta, G; Zambelli, G; Costi, T

    2016-06-01

    The eye lens is considered to be among the most radiosensitive human tissues. Brain CT scans may unnecessarily expose it to radiation even if the area of clinical interest is far from the eyes. The aim of this study is to implement a bismuth eye lens shielding system for Head-CT acquisitions in these cases. The study is focused on the assessment of the dosimetric characteristics of the shielding system as well as on its effect on image quality. The shielding system was tested in two set-ups which differ for distance ("contact" and "4 cm" Set up respectively). Scans were performed on a CTDI phantom and an anthropomorphic phantom. A reference set up without shielding system was acquired to establish a baseline. Image quality was assessed by signal (not HU converted), noise and contrast-to-noise ratio (CNR) evaluation. The overall dose reduction was evaluated by measuring the CTDIvol while the eye lens dose reduction was assessed by placing thermoluminescent dosimeters (TLDs) on an anthropomorphic phantom. The image quality analysis exhibits the presence of an artefact that mildly increases the CT number up to 3 cm below the shielding system. Below the artefact, the difference of the Signal and the CNR are negligible between the three different set-ups. Regarding the CTDI, the analysis demonstrates a decrease by almost 12 % (in the "contact" set-up) and 9 % (in the "4 cm" set-up). TLD measurements exhibit an eye lens dose reduction by 28.5 ± 5 and 21.1 ± 5 % respectively at the "contact" and the "4 cm" distance. No relevant artefact was found and image quality was not affected by the shielding system. Significant dose reductions were measured. These features make the shielding set-up useful for clinical implementation in both studied positions.

  11. Gamma Knife radiosurgery with CT image-based dose calculation.

    PubMed

    Xu, Andy Yuanguang; Bhatnagar, Jagdish; Bednarz, Greg; Niranjan, Ajay; Kondziolka, Douglas; Flickinger, John; Lunsford, L Dade; Huq, M Saiful

    2015-11-08

    The Leksell GammaPlan software version 10 introduces a CT image-based segmentation tool for automatic skull definition and a convolution dose calculation algorithm for tissue inhomogeneity correction. The purpose of this work was to evaluate the impact of these new approaches on routine clinical Gamma Knife treatment planning. Sixty-five patients who underwent CT image-guided Gamma Knife radiosurgeries at the University of Pittsburgh Medical Center in recent years were retrospectively investigated. The diagnoses for these cases include trigeminal neuralgia, meningioma, acoustic neuroma, AVM, glioma, and benign and metastatic brain tumors. Dose calculations were performed for each patient with the same dose prescriptions and the same shot arrangements using three different approaches: 1) TMR 10 dose calculation with imaging skull definition; 2) convolution dose calculation with imaging skull definition; 3) TMR 10 dose calculation with conventional measurement-based skull definition. For each treatment matrix, the total treatment time, the target coverage index, the selectivity index, the gradient index, and a set of dose statistics parameters were compared between the three calculations. The dose statistics parameters investigated include the prescription isodose volume, the 12 Gy isodose volume, the minimum, maximum and mean doses on the treatment targets, and the critical structures under consideration. The difference between the convolution and the TMR 10 dose calculations for the 104 treatment matrices were found to vary with the patient anatomy, location of the treatment shots, and the tissue inhomogeneities around the treatment target. An average difference of 8.4% was observed for the total treatment times between the convolution and the TMR algorithms. The maximum differences in the treatment times, the prescription isodose volumes, the 12 Gy isodose volumes, the target coverage indices, the selectivity indices, and the gradient indices from the convolution

  12. Gamma Knife radiosurgery with CT image-based dose calculation.

    PubMed

    Xu, Andy Yuanguang; Bhatnagar, Jagdish; Bednarz, Greg; Niranjan, Ajay; Kondziolka, Douglas; Flickinger, John; Lunsford, L Dade; Huq, M Saiful

    2015-11-01

    The Leksell GammaPlan software version 10 introduces a CT image-based segmentation tool for automatic skull definition and a convolution dose calculation algorithm for tissue inhomogeneity correction. The purpose of this work was to evaluate the impact of these new approaches on routine clinical Gamma Knife treatment planning. Sixty-five patients who underwent CT image-guided Gamma Knife radiosurgeries at the University of Pittsburgh Medical Center in recent years were retrospectively investigated. The diagnoses for these cases include trigeminal neuralgia, meningioma, acoustic neuroma, AVM, glioma, and benign and metastatic brain tumors. Dose calculations were performed for each patient with the same dose prescriptions and the same shot arrangements using three different approaches: 1) TMR 10 dose calculation with imaging skull definition; 2) convolution dose calculation with imaging skull definition; 3) TMR 10 dose calculation with conventional measurement-based skull definition. For each treatment matrix, the total treatment time, the target coverage index, the selectivity index, the gradient index, and a set of dose statistics parameters were compared between the three calculations. The dose statistics parameters investigated include the prescription isodose volume, the 12 Gy isodose volume, the minimum, maximum and mean doses on the treatment targets, and the critical structures under consideration. The difference between the convolution and the TMR 10 dose calculations for the 104 treatment matrices were found to vary with the patient anatomy, location of the treatment shots, and the tissue inhomogeneities around the treatment target. An average difference of 8.4% was observed for the total treatment times between the convolution and the TMR algorithms. The maximum differences in the treatment times, the prescription isodose volumes, the 12 Gy isodose volumes, the target coverage indices, the selectivity indices, and the gradient indices from the convolution

  13. Dose Reduction in Tomosynthesis of the Wrist.

    PubMed

    Becker, Anton S; Martini, Katharina; Higashigaito, Kai; Guggenberger, Roman; Andreisek, Gustav; Frauenfelder, Thomas

    2017-01-01

    The purpose of this study was to quantitatively and qualitatively determine the impact of radiation dose reduction on the image noise and quality of tomosynthesis studies of the wrist. Imaging of six cadaver wrists was performed with tomosynthesis in anteroposterior position at a tube voltage of 60 kV and tube current of 80 mA and subsequently at 60 or 50 kV with different tube currents of 80, 40, or 32 mA. Dose-area products (DAP) were obtained from the electronically logged protocol. Image noise was measured with an ROI. Two independent and blinded readers evaluated all images. Interreader agreement was measured with a Cohen kappa. Readers assessed overall quality and delineation of soft tissue, cortical bone, and trabecular bone on a 4-point Likert scale. The highest DAP (3.892 ± 0.432 Gy · cm(2)) was recorded for images obtained with 60 kV and 80 mA; the lowest (0.857 ± 0.178 Gy · cm(2)) was recorded for images obtained with 50 kV and 32 mA. Noise was highest when a combination of 50 kV and 32 mA (389 ± 26.6) was used and lowest when a combination of 60 kV and 80 mA (218 ± 12.3) was used. The amount of noise on images acquired using 60 kV and 80 mA was statistically significantly different from the amount measured on all other images (p < 0.0001). Interreader agreement was excellent (κ = 0.93). Delineation of anatomy and overall quality were scored best on images obtained with 60 kV and 80 mA and worst on images obtained with 50 kV and 32 mA. The difference in delineation and quality on images obtained using 50 kV and 40 mA was not statistically significantly different compared with images obtained using 60 kV and 80 mA. Significant dose reduction for tomosynthesis of the wrist is possible while image quality and delineation of anatomic structures remain preserved.

  14. SU-E-I-86: Ultra-Low Dose Computed Tomography Attenuation Correction for Pediatric PET CT Using Adaptive Statistical Iterative Reconstruction (ASiR™)

    SciTech Connect

    Brady, S; Shulkin, B

    2015-06-15

    Purpose: To develop ultra-low dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultra-low doses (10–35 mAs). CT quantitation: noise, low-contrast resolution, and CT numbers for eleven tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% CTDIvol (0.39/3.64; mGy) radiation dose from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUVbw) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation organ dose, as derived from patient exam size specific dose estimate (SSDE), was converted to effective dose using the standard ICRP report 103 method. Effective dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative patient population dose reduction and noise control. Results: CT numbers were constant to within 10% from the non-dose reduced CTAC image down to 90% dose reduction. No change in SUVbw, background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols reconstructed with ASiR and down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62%–86% (3.2/8.3−0.9/6.2; mSv). Noise magnitude in dose-reduced patient images increased but was not statistically different from pre dose-reduced patient images. Conclusion: Using ASiR allowed for aggressive reduction in CTAC dose with no change in PET reconstructed images while maintaining sufficient image quality for co

  15. Survey of volume CT dose index in Japan in 2014

    PubMed Central

    Kawaguchi, A; Kobayashi, K; Kinomura, Y; Kobayashi, M; Asada, Y; Minami, K; Suzuki, S; Chida, K

    2015-01-01

    Objective: The aims of this study are to propose a new set of Japanese diagnostic reference levels (DRLs) for 2014 and to study the impact of tube voltage and the type of reconstruction algorithm on patient doses. The volume CT dose index (CTDIvol) for adult and paediatric patients is assessed and compared with the results of a 2011 national survey and data from other countries. Methods: Scanning procedures for the head (non-helical and helical), chest and upper abdomen were examined for adults and 5-year-old children. A questionnaire concerning the following items was sent to 3000 facilities: tube voltage, use of reconstruction algorithms and displayed CTDIvol. Results: The mean CTDIvol values for paediatric examinations using voltages ranging from 80 to 100 kV were significantly lower than those for paediatric examinations using 120 kV. For adult examinations, the use of iterative reconstruction algorithms significantly reduced the mean CTDIvol values compared with the use of filtered back projection. Paediatric chest and abdominal scans showed slightly higher mean CTDIvol values in 2014 than in 2011. The proposed DRLs for adult head and abdominal scans were higher than those reported in other countries. Conclusion: The results imply that further optimization of CT examination protocols is required for adult head and abdominal scans as well as paediatric chest and abdominal scans. Advances in knowledge: Low-tube-voltage CT may be useful for reducing radiation doses in paediatric patients. The mean CTDIvol values for paediatric scans showed little difference that could be attributed to the choice of reconstruction algorithm. PMID:26043158

  16. Diagnostic value of CT-localizer and axial low-dose computed tomography for the detection of drug body packing.

    PubMed

    Aissa, Joel; Kohlmeier, Antonia; Rubbert, Christian; Hohn, Ulrich; Blondin, Dirk; Schleich, Christoph; Kröpil, Patric; Boos, Johannes; Antoch, Gerald; Miese, Falk

    2016-01-01

    The purpose of this study was to assess the diagnostic performance of CT-localizers in the detection of intracorporal containers. This study was approved by the research ethics committee of our clinic. From March 2012 to March 2013, 108 subjects were referred to our institute with suspected body packing. The CT-localizer and the axial CT-images were compared by two blinded observers retrospectively. Presence of body packs was assessed in consensus. Sensitivity and specificity, PPV and NPV of the CT-localizer were calculated. Packets were detected in the CT-localizer of 19 suspects. In 28 of 108 cases packs were detected in axial CT-images. Sensitivity of CT-localizer for detection of packs was 0.68, and specificity was 1.00. There were no cases rated as false positive. The PPV was 1.0 and the NPV was 0.89. The omission of the axial CT-images would have led to a mean radiation dose reduction of 1.94 ± 0.5 mSv. The value of CT-localizers lies in their high PPV. Localizers are limited by low sensitivity, compared to axial CT-images in screening of potential body packers. However, in positive cases their high PPV may possibly allow to omit the complete axial abdominal CT to achieve even lower radiation exposure. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  17. Established and emerging dose reduction methods in cardiac computed tomography.

    PubMed

    Small, Gary R; Kazmi, Mustapha; Dekemp, Robert A; Chow, Benjamin J W

    2011-08-01

    Cardiac computed tomography (CT) is a non-invasive modality that is commonly used as an alternative to invasive coronary angiography for the investigation of coronary artery disease. The enthusiasm for this technology has been tempered by a growing appreciation of the potential risks of malignancy associated with the use of ionising radiation. In the spirit of minimizing patient risk, the medical profession and industry have worked hard to developed methods and protocols to reduce patient radiation exposure while maintaining excellent diagnostic accuracy. A complete understanding of radiation reduction techniques will allow clinicians to reduce patient risk while providing an important diagnostic service. This review will consider the established and emerging techniques that may be adopted to reduce patient absorbed doses from x-ray CT. By modifying (1) x-ray tube output, (2) imaging time (scan duration), (3) imaging distance (scan length) and (4) the appropriate use of shielding, clinicians will be able to adhere to the 'as low as reasonably achievable (ALARA)' principle.

  18. Effect of Third-generation Dual-source CT Technology on Image Quality of Low-dose Chest CT.

    PubMed

    Sui, Xin; Xu, Xiaoli; Song, Lan; DU, Qianni; Wang, Xiao; Jing, Zhengyu; Song, Wei

    2017-02-20

    Objective To evaluate the image quality and radiation dose of third-generation dual-source CT with tin filtration for spectral shaping and iterative reconstructions.Methods Thirty-five patients underwent low-dose CT (LDCT) for lung cancer screening on second-generation dual-source CT and follow-ups on third-generation dual-source CT. Image quality and radiation dose were compared between the two examinations.ResultsThe radiation dose of third-generation dual-source CT [dose-length product (DLP)(49.7±18.2)mGy·cm, effective dose (ED)(0.73±0.26)mSv] was lower than second-generation dual-source CT [DLP (86.37±13.44) mGy·cm, ED(1.20±0.42)mSv](t=6.01, P=0.000;t=6.57, P=0.000). The objective image noise of second-generation dual-source CT [(25.7±2.9)HU] was higher than that of third-generation dual-soure CT[(18.6±4.2)HU](t=5.24,P=0.000).The subjective image noise of second-generation dual-source CT [(4.60±0.49)scores] was significantly lower than that of third-generation dual-source CT [(4.80±0.40)scores] (t=4.15, P=0.000). Conclusion Chest CT for the detection of pulmonary nodules can be performed with third-generation dual-source CT that produces high image quality and low radiation dose when using a stellar infinity detector with spectral shaping.

  19. SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms

    NASA Astrophysics Data System (ADS)

    Cros, Maria; Joemai, Raoul M. S.; Geleijns, Jacob; Molina, Diego; Salvadó, Marçal

    2017-08-01

    This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses and effective doses in ICRP anthropomorphic adult reference computational phantoms for acquisitions with the Aquilion ONE CT scanner (Toshiba). MC simulation was validated by comparing CTDI measurements within standard CT dose phantoms with results from simulation under the same conditions. SimDoseCT consists of a graphical user interface connected to a MySQL database, which contains the look-up-tables that were generated with MC simulations for volumetric acquisitions at different scan positions along the phantom using any tube voltage, bow tie filter, focal spot and nine different beam widths. Two different methods were developed to estimate organ doses and effective doses from acquisitions using other available beam widths in the scanner. A correction factor was used to estimate doses in helical acquisitions. Hence, the user can select any available protocol in the Aquilion ONE scanner for a standard adult male or female and obtain the dose results through the software interface. Agreement within 9% between CTDI measurements and simulations allowed the validation of the MC program. Additionally, the algorithm for dose reporting in SimDoseCT was validated by comparing dose results from this tool with those obtained from MC simulations for three volumetric acquisitions (head, thorax and abdomen). The comparison was repeated using eight different collimations and also for another collimation in a helical abdomen examination. The results showed differences of 0.1 mSv or less for absolute dose in most organs and also in the effective dose calculation. The software provides a suitable tool for dose assessment in standard adult patients undergoing CT

  20. SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms.

    PubMed

    Cros, Maria; Joemai, Raoul M S; Geleijns, Jacob; Molina, Diego; Salvadó, Marçal

    2017-07-17

    This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses and effective doses in ICRP anthropomorphic adult reference computational phantoms for acquisitions with the Aquilion ONE CT scanner (Toshiba). MC simulation was validated by comparing CTDI measurements within standard CT dose phantoms with results from simulation under the same conditions. SimDoseCT consists of a graphical user interface connected to a MySQL database, which contains the look-up-tables that were generated with MC simulations for volumetric acquisitions at different scan positions along the phantom using any tube voltage, bow tie filter, focal spot and nine different beam widths. Two different methods were developed to estimate organ doses and effective doses from acquisitions using other available beam widths in the scanner. A correction factor was used to estimate doses in helical acquisitions. Hence, the user can select any available protocol in the Aquilion ONE scanner for a standard adult male or female and obtain the dose results through the software interface. Agreement within 9% between CTDI measurements and simulations allowed the validation of the MC program. Additionally, the algorithm for dose reporting in SimDoseCT was validated by comparing dose results from this tool with those obtained from MC simulations for three volumetric acquisitions (head, thorax and abdomen). The comparison was repeated using eight different collimations and also for another collimation in a helical abdomen examination. The results showed differences of 0.1 mSv or less for absolute dose in most organs and also in the effective dose calculation. The software provides a suitable tool for dose assessment in standard adult patients undergoing CT

  1. Gamma regularization based reconstruction for low dose CT.

    PubMed

    Zhang, Junfeng; Chen, Yang; Hu, Yining; Luo, Limin; Shu, Huazhong; Li, Bicao; Liu, Jin; Coatrieux, Jean-Louis

    2015-09-07

    Reducing the radiation in computerized tomography is today a major concern in radiology. Low dose computerized tomography (LDCT) offers a sound way to deal with this problem. However, more severe noise in the reconstructed CT images is observed under low dose scan protocols (e.g. lowered tube current or voltage values). In this paper we propose a Gamma regularization based algorithm for LDCT image reconstruction. This solution is flexible and provides a good balance between the regularizations based on l0-norm and l1-norm. We evaluate the proposed approach using the projection data from simulated phantoms and scanned Catphan phantoms. Qualitative and quantitative results show that the Gamma regularization based reconstruction can perform better in both edge-preserving and noise suppression when compared with other norms.

  2. The impact of iterative reconstruction on image quality and radiation dose in thoracic and abdominal CT.

    PubMed

    Kalmar, Peter I; Quehenberger, Franz; Steiner, Jürgen; Lutfi, Andre; Bohlsen, Dennis; Talakic, Emina; Hassler, Eva Maria; Schöllnast, Helmut

    2014-08-01

    To compare the image quality and radiation dose between iterative reconstruction (IR) and standard filtered back projection (FBP) in CT of the chest and abdomen. Thoracic CT was performed in 50 patients (38 male, 12 female; mean age, 51 ± 23 yrs; range, 7-85 yrs) and abdominal CT was performed in 50 patients (36 male, 14 female; mean age, 62 ± 13 yrs; range, 20-85 yrs), using IR as well as FBP for image reconstruction. Image noise was quantitatively assessed measuring standard deviation of Hounsfield Units (HU) in defined regions of interest in subcutaneous tissue. Scan length and Computed Tomography Dose Index (CTDI) were documented. Scan length, image noise, and CTDI of both reconstruction techniques were compared by using paired tests according to the nature of variables (McNemar test or Student t test). Overall subjective image quality and subjective image noise were compared. There was no significant difference between the protocols in terms of mean scan length (p>0.05). Image noise was statistically significantly higher with IR, although the difference was clinically insignificant (13.3 ± 3.0 HU and 13.6 ± 3.0 HU for thoracic CT and 11.5 ± 3.1 HU and 11.7 ± 3.0 HU for abdominal CT, p<0.05). There was no significant difference in overall subjective image quality and subjective image noise. The radiation dose was significantly lower with IR. Volume-weighted CTDI decreased by 64% (6.2 ± 2.5 mGy versus 17.1 ± 9.5 mGy, p<0.001) for thoracic CT and by 58% (7.8 ± 4.6 mGy versus 18.5 ± 8.6 mGy, p<0.001) for abdominal CT. Our study shows that in thoracic and abdominal CT with IR, there is no clinically significant impact on image quality, yet a significant radiation dose reduction compared to FBP. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Effects of sparse sampling schemes on image quality in low-dose CT

    SciTech Connect

    Abbas, Sajid; Lee, Taewon; Cho, Seungryong; Shin, Sukyoung; Lee, Rena

    2013-11-15

    Purpose: Various scanning methods and image reconstruction algorithms are actively investigated for low-dose computed tomography (CT) that can potentially reduce a health-risk related to radiation dose. Particularly, compressive-sensing (CS) based algorithms have been successfully developed for reconstructing images from sparsely sampled data. Although these algorithms have shown promises in low-dose CT, it has not been studied how sparse sampling schemes affect image quality in CS-based image reconstruction. In this work, the authors present several sparse-sampling schemes for low-dose CT, quantitatively analyze their data property, and compare effects of the sampling schemes on the image quality.Methods: Data properties of several sampling schemes are analyzed with respect to the CS-based image reconstruction using two measures: sampling density and data incoherence. The authors present five different sparse sampling schemes, and simulated those schemes to achieve a targeted dose reduction. Dose reduction factors of about 75% and 87.5%, compared to a conventional scan, were tested. A fully sampled circular cone-beam CT data set was used as a reference, and sparse sampling has been realized numerically based on the CBCT data.Results: It is found that both sampling density and data incoherence affect the image quality in the CS-based reconstruction. Among the sampling schemes the authors investigated, the sparse-view, many-view undersampling (MVUS)-fine, and MVUS-moving cases have shown promising results. These sampling schemes produced images with similar image quality compared to the reference image and their structure similarity index values were higher than 0.92 in the mouse head scan with 75% dose reduction.Conclusions: The authors found that in CS-based image reconstructions both sampling density and data incoherence affect the image quality, and suggest that a sampling scheme should be devised and optimized by use of these indicators. With this strategic

  4. Personalized low dose CT via variable kVp

    NASA Astrophysics Data System (ADS)

    Wang, Hui; Jin, Yannan; Yao, Yangyang; Wu, Mingye; Yan, Ming; Tao, Kun; Yin, Zhye; De Man, Bruno

    2015-03-01

    Computerized Tomography (CT) is a powerful radiographic imaging technology but the health risk due to the exposure of x-ray radiation has drawn wide concern. In this study, we propose to use kVp modulation to reduce the radiation dose and achieve the personalized low dose CT. Two sets of simulation are performed to demonstrate the effectiveness of kVp modulation and the corresponding calibration. The first simulation used the helical body phantom (HBP) that is an elliptical water cylinder with high density bone inserts. The second simulation uses the NCAT phantom to emulate the practical use of kVp modulation approach with region of interest (ROI) selected in the cardiac region. The kVp modulation profile could be optimized view by view based on the knowledge of patient attenuation. A second order correction is applied to eliminate the beam hardening artifacts. To simplify the calibration process, we first generate the calibration vectors for a few representative spectra and then acquire other calibration vectors with interpolation. The simulation results demonstrate the beam hardening artifacts in the images with kVp modulation can be eliminated with proper beam hardening correction. The results also show that the simplification of calibration did not impair the image quality: the calibration with the simplified and the complete vectors both eliminate the artifacts effectively and the results are comparable. In summary, this study demonstrates the feasibility of kVp modulation and gives a practical way to calibrate the high order beam hardening artifacts.

  5. Evidence of dose saving in routine CT practice using iterative reconstruction derived from a national diagnostic reference level survey

    PubMed Central

    Hayton, A; Beveridge, T; Marks, P; Wallace, A

    2015-01-01

    Objective: To assess the influence and significance of the use of iterative reconstruction (IR) algorithms on patient dose in CT in Australia. Methods: We examined survey data submitted to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) National Diagnostic Reference Level Service (NDRLS) during 2013 and 2014. We compared median survey dose metrics with categorization by scan region and use of IR. Results: The use of IR results in a reduction in volume CT dose index of between 17% and 44% and a reduction in dose–length product of between 14% and 34% depending on the specific scan region. The reduction was highly significant (p < 0.001, Wilcoxon rank-sum test) for all six scan regions included in the NDRLS. Overall, 69% (806/1167) of surveys included in the analysis used IR. Conclusion: The use of IR in CT is achieving dose savings of 20–30% in routine practice in Australia. IR appears to be widely used by participants in the ARPANSA NDRLS with approximately 70% of surveys submitted employing this technique. Advances in knowledge: This study examines the impact of the use of IR on patient dose in CT on a national scale. PMID:26133224

  6. Effective doses from cone beam CT investigation of the jaws

    PubMed Central

    Davies, J; Johnson, B; Drage, NA

    2012-01-01

    Objectives The purpose of the study was to calculate the effective dose delivered to the patient undergoing cone beam (CB) CT of the jaws and maxillofacial complex using the i-CAT Next Generation CBCT scanner (Imaging Sciences International, Hatfield, PA). Methods A RANDO® phantom (The Phantom Laboratory, Salem, NY) containing thermoluminence dosemeters were scanned 10 times for each of the 6 imaging protocols. Effective doses for each protocol were calculated using the 1990 and approved 2007 International Commission on Radiological Protection (ICRP) recommended tissue weighting factors (E1990, E2007). Results The effective dose for E1990 and E2007, respectively, were: full field of view (FOV) of the head, 47 μSv and 78 μSv; 13 cm scan of the jaws, 44 μSv and 77 μSv; 6 cm standard mandible, 35 μSv and 58 μSv; 6 cm high resolution mandible, 69 μSv and 113 μSv; 6 cm standard maxilla, 18 μSv and 32 μSv; and 6 cm high resolution maxilla, 35 μSv and 60 μSv. Conclusions Using the new generation of CBCT scanner, the effective dose is lower than the original generation machine for a similar FOV using the ICRP 2007 tissue weighting factors. PMID:22184626

  7. A comprehensive study on the relationship between the image quality and imaging dose in low-dose cone beam CT

    NASA Astrophysics Data System (ADS)

    Yan, Hao; Cervino, Laura; Jia, Xun; Jiang, Steve B.

    2012-04-01

    While compressed sensing (CS)-based algorithms have been developed for the low-dose cone beam CT (CBCT) reconstruction, a clear understanding of the relationship between the image quality and imaging dose at low-dose levels is needed. In this paper, we qualitatively investigate this subject in a comprehensive manner with extensive experimental and simulation studies. The basic idea is to plot both the image quality and imaging dose together as functions of the number of projections and mAs per projection over the whole clinically relevant range. On this basis, a clear understanding of the tradeoff between the image quality and imaging dose can be achieved and optimal low-dose CBCT scan protocols can be developed to maximize the dose reduction while minimizing the image quality loss for various imaging tasks in image-guided radiation therapy (IGRT). Main findings of this work include (1) under the CS-based reconstruction framework, image quality has little degradation over a large range of dose variation. Image quality degradation becomes evident when the imaging dose (approximated with the x-ray tube load) is decreased below 100 total mAs. An imaging dose lower than 40 total mAs leads to a dramatic image degradation, and thus should be used cautiously. Optimal low-dose CBCT scan protocols likely fall in the dose range of 40-100 total mAs, depending on the specific IGRT applications. (2) Among different scan protocols at a constant low-dose level, the super sparse-view reconstruction with the projection number less than 50 is the most challenging case, even with strong regularization. Better image quality can be acquired with low mAs protocols. (3) The optimal scan protocol is the combination of a medium number of projections and a medium level of mAs/view. This is more evident when the dose is around 72.8 total mAs or below and when the ROI is a low-contrast or high-resolution object. Based on our results, the optimal number of projections is around 90 to 120. (4

  8. A comprehensive study on the relationship between the image quality and imaging dose in low-dose cone beam CT.

    PubMed

    Yan, Hao; Cervino, Laura; Jia, Xun; Jiang, Steve B

    2012-04-07

    While compressed sensing (CS)-based algorithms have been developed for the low-dose cone beam CT (CBCT) reconstruction, a clear understanding of the relationship between the image quality and imaging dose at low-dose levels is needed. In this paper, we qualitatively investigate this subject in a comprehensive manner with extensive experimental and simulation studies. The basic idea is to plot both the image quality and imaging dose together as functions of the number of projections and mAs per projection over the whole clinically relevant range. On this basis, a clear understanding of the tradeoff between the image quality and imaging dose can be achieved and optimal low-dose CBCT scan protocols can be developed to maximize the dose reduction while minimizing the image quality loss for various imaging tasks in image-guided radiation therapy (IGRT). Main findings of this work include (1) under the CS-based reconstruction framework, image quality has little degradation over a large range of dose variation. Image quality degradation becomes evident when the imaging dose (approximated with the x-ray tube load) is decreased below 100 total mAs. An imaging dose lower than 40 total mAs leads to a dramatic image degradation, and thus should be used cautiously. Optimal low-dose CBCT scan protocols likely fall in the dose range of 40-100 total mAs, depending on the specific IGRT applications. (2) Among different scan protocols at a constant low-dose level, the super sparse-view reconstruction with the projection number less than 50 is the most challenging case, even with strong regularization. Better image quality can be acquired with low mAs protocols. (3) The optimal scan protocol is the combination of a medium number of projections and a medium level of mAs/view. This is more evident when the dose is around 72.8 total mAs or below and when the ROI is a low-contrast or high-resolution object. Based on our results, the optimal number of projections is around 90 to 120. (4

  9. A comprehensive study on the relationship between image quality and imaging dose in low-dose cone beam CT

    PubMed Central

    Yan, Hao; Cervino, Laura; Jia, Xun; Jiang, Steve B.

    2012-01-01

    While compressed sensing (CS) based algorithms have been developed for low-dose cone beam CT (CBCT) reconstruction, a clear understanding on the relationship between the image quality and imaging dose at low dose levels is needed. In this paper, we qualitatively investigate this subject in a comprehensive manner with extensive experimental and simulation studies. The basic idea is to plot both the image quality and imaging dose together as functions of number of projections and mAs per projection over the whole clinically relevant range. On this basis, a clear understanding on the tradeoff between image quality and imaging dose can be achieved and optimal low-dose CBCT scan protocols can be developed to maximize the dose reduction while minimizing the image quality loss for various imaging tasks in image guided radiation therapy (IGRT). Main findings of this work include: 1) Under the CS-based reconstruction framework, image quality has little degradation over a large range of dose variation. Image quality degradation becomes evident when the imaging dose (approximated with the x-ray tube load) is decreased below 100 total mAs. An imaging dose lower than 40 total mAs leads to a dramatic image degradation, and thus should be used cautiously. Optimal low-dose CBCT scan protocols likely fall in the dose range of 40–100 total mAs, depending on the specific IGRT applications. 2) Among different scan protocols at a constant low-dose level, the super sparse-view reconstruction with projection number less than 50 is the most challenging case, even with strong regularization. Better image quality can be acquired with low mAs protocols. 3) The optimal scan protocol is the combination of a medium number of projections and a medium level of mAs/view. This is more evident when the dose is around 72.8 total mAs or below and when the ROI is a low-contrast or high-resolution object. Based on our results, the optimal number of projections is around 90 to 120. 4) The clinically

  10. Dose distribution for dental cone beam CT and its implication for defining a dose index

    PubMed Central

    Pauwels, R; Theodorakou, C; Walker, A; Bosmans, H; Jacobs, R; Horner, K; Bogaerts, R

    2012-01-01

    Objectives To characterize the dose distribution for a range of cone beam CT (CBCT) units, investigating different field of view sizes, central and off-axis geometries, full or partial rotations of the X-ray tube and different clinically applied beam qualities. The implications of the dose distributions on the definition and practicality of a CBCT dose index were assessed. Methods Dose measurements on CBCT devices were performed by scanning cylindrical head-size water and polymethyl methacrylate phantoms, using thermoluminescent dosemeters, a small-volume ion chamber and radiochromic films. Results It was found that the dose distribution can be asymmetrical for dental CBCT exposures throughout a homogeneous phantom, owing to an asymmetrical positioning of the isocentre and/or partial rotation of the X-ray source. Furthermore, the scatter tail along the z-axis was found to have a distinct shape, generally resulting in a strong drop (90%) in absorbed dose outside the primary beam. Conclusions There is no optimal dose index available owing to the complicated exposure geometry of CBCT and the practical aspects of quality control measurements. Practical validation of different possible dose indices is needed, as well as the definition of conversion factors to patient dose. PMID:22752320

  11. Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: phantom studies

    NASA Astrophysics Data System (ADS)

    Liu, Wenlei; Rong, Junyan; Gao, Peng; Liao, Qimei; Lu, HongBing

    2016-03-01

    X-ray scatter poses a significant limitation to image quality in cone-beam CT (CBCT), as well as beam hardening, resulting in image artifacts, contrast reduction, and lack of CT number accuracy. Meanwhile the x-ray radiation dose is also non-ignorable. Considerable scatter or beam hardening correction methods have been developed, independently, and rarely combined with low-dose CT reconstruction. In this paper, we combine scatter suppression with beam hardening correction for sparse-view CT reconstruction to improve CT image quality and reduce CT radiation. Firstly, scatter was measured, estimated, and removed using measurement-based methods, assuming that signal in the lead blocker shadow is only attributable to x-ray scatter. Secondly, beam hardening was modeled by estimating an equivalent attenuation coefficient at the effective energy, which was integrated into the forward projector of the algebraic reconstruction technique (ART). Finally, the compressed sensing (CS) iterative reconstruction is carried out for sparse-view CT reconstruction to reduce the CT radiation. Preliminary Monte Carlo simulated experiments indicate that with only about 25% of conventional dose, our method reduces the magnitude of cupping artifact by a factor of 6.1, increases the contrast by a factor of 1.4 and the CNR by a factor of 15. The proposed method could provide good reconstructed image from a few view projections, with effective suppression of artifacts caused by scatter and beam hardening, as well as reducing the radiation dose. With this proposed framework and modeling, it may provide a new way for low-dose CT imaging.

  12. Comparison of effective radiation doses from X-ray, CT, and PET/CT in pediatric patients with neuroblastoma using a dose monitoring program

    PubMed Central

    Kim, Yeun Yoon; Shin, Hyun Joo; Kim, Myung-Joon; Lee, Mi-Jung

    2016-01-01

    PURPOSE We aimed to evaluate the use of a dose monitoring program for calculating and comparing the diagnostic radiation doses in pediatric patients with neuroblastoma. METHODS We retrospectively reviewed diagnostic and therapeutic imaging studies performed on pediatric patients with neuroblastoma from 2003 to 2014. We calculated the mean effective dose per exam for X-ray, conventional computed tomography (CT), and CT of positron emission tomography/computed tomography (PET/CT) from the data collected using a dose monitoring program (DoseTrack group) since October 2012. Using the data, we estimated the cumulative dose per person and the relative dose from each modality in all patients (Total group). The effective dose from PET was manually calculated for all patients. RESULTS We included 63 patients with a mean age of 3.2±3.5 years; 28 had a history of radiation therapy, with a mean irradiated dose of 31.9±23.2 Gy. The mean effective dose per exam was 0.04±0.19 mSv for X-ray, 1.09±1.11 mSv for CT, and 8.35±7.45 mSv for CT of PET/CT in 31 patients of the Dose-Track group. The mean estimated cumulative dose per patient in the Total group was 3.43±2.86 mSv from X-ray (8.5%), 7.66±6.09 mSv from CT (19.1%), 18.35±13.52 mSv from CT of PET/CT (45.7%), and 10.71±10.05 mSv from PET (26.7%). CONCLUSION CT of PET/CT contributed nearly half of the total cumulative dose in pediatric patients with neuroblastoma. The radiation dose from X-ray was not negligible because of the large number of X-ray images. A dose monitoring program can be useful for calculating radiation doses in patients with cancer. PMID:27306659

  13. Comparison of effective radiation doses from X-ray, CT, and PET/CT in pediatric patients with neuroblastoma using a dose monitoring program.

    PubMed

    Kim, Yeun Yoon; Shin, Hyun Joo; Kim, Myung Joon; Lee, Mi-Jung

    2016-01-01

    We aimed to evaluate the use of a dose monitoring program for calculating and comparing the diagnostic radiation doses in pediatric patients with neuroblastoma. We retrospectively reviewed diagnostic and therapeutic imaging studies performed on pediatric patients with neuroblastoma from 2003 to 2014. We calculated the mean effective dose per exam for X-ray, conventional computed tomography (CT), and CT of positron emission tomography/computed tomography (PET/CT) from the data collected using a dose monitoring program (DoseTrack group) since October 2012. Using the data, we estimated the cumulative dose per person and the relative dose from each modality in all patients (Total group). The effective dose from PET was manually calculated for all patients. We included 63 patients with a mean age of 3.2±3.5 years; 28 had a history of radiation therapy, with a mean irradiated dose of 31.9±23.2 Gy. The mean effective dose per exam was 0.04±0.19 mSv for X-ray, 1.09±1.11 mSv for CT, and 8.35±7.45 mSv for CT of PET/CT in 31 patients of the DoseTrack group. The mean estimated cumulative dose per patient in the Total group was 3.43±2.86 mSv from X-ray (8.5%), 7.66±6.09 mSv from CT (19.1%), 18.35±13.52 mSv from CT of PET/CT (45.7%), and 10.71±10.05 mSv from PET (26.7%). CT of PET/CT contributed nearly half of the total cumulative dose in pediatric patients with neuroblastoma. The radiation dose from X-ray was not negligible because of the large number of X-ray images. A dose monitoring program can be useful for calculating radiation doses in patients with cancer.

  14. Six steps to a successful dose-reduction strategy

    SciTech Connect

    Bennett, M.

    1995-03-01

    The increased importance of demonstrating achievement of the ALARA principle has helped produce a proliferation of dose-reduction ideas. Across a company there may be many dose-reduction items being pursued in a variety of areas. However, companies have a limited amount of resource and, therefore, to ensure funding is directed to those items which will produce the most benefit and that all areas apply a common policy, requires the presence of a dose-reduction strategy. Six steps were identified in formulating the dose-reduction strategy for Rolls-Royce and Associates (RRA): (1) collating the ideas; (2) quantitatively evaluating them on a common basis; (3) prioritizing the ideas in terms of cost benefit, (4) implementation of the highest priority items; (5) monitoring their success; (6) periodically reviewing the strategy. Inherent in producing the dose-reduction strategy has been a comprehensive dose database and the RRA-developed dose management computer code DOMAIN, which allows prediction of dose rates and dose. The database enabled high task dose items to be identified, assisted in evaluating dose benefits, and monitored dose trends once items had been implemented. The DOMAIN code was used both in quantifying some of the project dose benefits and its results, such as dose contours, used in some of the dose-reduction items themselves. In all, over fifty dose-reduction items were evaluated in the strategy process and the items which will give greatest benefit are being implemented. The strategy has been successful in giving renewed impetus and direction to dose-reduction management.

  15. Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose.

    PubMed

    Uhrig, Monika; Simons, David; Kachelrieß, Marc; Pisana, Francesco; Kuchenbecker, Stefan; Schlemmer, Heinz-Peter

    2016-06-21

    Dual energy CT (DECT) has proven its potential in oncological imaging. Considering the repeated follow-up examinations, radiation dose should not exceed conventional single energy CT (SECT). Comparison studies on the same scanner with a large number of patients, considering patient geometries and image quality, and exploiting full potential of SECT dose reduction are rare. Purpose of this retrospective study was to compare dose of dual source DECT versus dose-optimized SECT abdominal imaging in clinical routine. One hundred patients (62y (±14)) had either contrast-enhanced SECT including automatic voltage control (44) or DECT (56). CT dose index (CTDIvol), size-specific dose-estimate (SSDE) and dose-length product (DLP) were reported. Image noise (SD) was recorded as mean of three ROIs placed in subcutaneous fat and normalized to dose by [Formula: see text] . For dose-normalized contrast-to-noise ratio (CNRD), mean attenuation of psoas muscle (CTmuscle) and subcutaneous fat (CTfat) were compared by CNRD = (CTmuscle - CTfat)/SDn. Statistical significance was tested with two-sided t-test (α = 0.05). There was no significant difference (p < 0.05) between DECT and SECT: Mean CTDIvol was 14.2 mGy (±3.9) (DECT) and 14.3 mGy (±4.5) (SECT). Mean DLP was 680 mGy*cm (±220) (DECT) and 665 mGy*cm (±231) (SECT). Mean SSDE was 15.7 mGy (±1.9) (DECT) and 16.1 mGy (±2.5) (SECT). Mean SDn was 42.2 (±13.9) HU [Formula: see text] (DECT) and 47.8 (±14.9) HU [Formula: see text] (SECT). Mean CNRD was 3.9 (±1.3) [Formula: see text]. (DECT) and 4.0 (±1.3) [Formula: see text] (SECT). Abdominal DECT is feasible without increasing radiation dose or deteriorating image quality, even compared to dose-optimized SECT including automatic voltage control. Thus DECT can contribute to sophisticated oncological imaging without dose penalty.

  16. Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scanner.

    PubMed

    Geleijns, J; Salvadó Artells, M; de Bruin, P W; Matter, R; Muramatsu, Y; McNitt-Gray, M F

    2009-05-21

    Computed tomography (CT) dosimetry should be adapted to the rapid developments in CT technology. Recently a 160 mm wide, 320 detector row, cone beam CT scanner that challenges the existing Computed Tomography Dose Index (CTDI) dosimetry paradigm was introduced. The purpose of this study was to assess dosimetric characteristics of this cone beam scanner, to study the appropriateness of existing CT dose metrics and to suggest a pragmatic approach for CT dosimetry for cone beam scanners. Dose measurements with a small Farmer-type ionization chamber and with 100 mm and 300 mm long pencil ionization chambers were performed free in air to characterize the cone beam. According to the most common dose metric in CT, namely CTDI, measurements were also performed in 150 mm and 350 mm long CT head and CT body dose phantoms with 100 mm and 300 mm long pencil ionization chambers, respectively. To explore effects that cannot be measured with ionization chambers, Monte Carlo (MC) simulations of the dose distribution in 150 mm, 350 mm and 700 mm long CT head and CT body phantoms were performed. To overcome inconsistencies in the definition of CTDI100 for the 160 mm wide cone beam CT scanner, doses were also expressed as the average absorbed dose within the pencil chamber (D100). Measurements free in air revealed excellent correspondence between CTDI300air and D100air, while CTDI100air substantially underestimates CTDI300air. Results of measurements in CT dose phantoms and corresponding MC simulations at centre and peripheral positions were weighted and revealed good agreement between CTDI300w, D100w and CTDI600w, while CTDI100w substantially underestimates CTDI300w. D100w provides a pragmatic metric for characterizing the dose of the 160 mm wide cone beam CT scanner. This quantity can be measured with the widely available 100 mm pencil ionization chamber within 150 mm long CT dose phantoms. CTDI300w measured in 350 mm long CT dose phantoms serves as an appropriate standard of

  17. Quality initiative: Quantifying and reducing dose in multiphase liver CT: Eliminating the nonenhanced study and using conscientious Z-creep.

    PubMed

    Bastawrous, Sarah; Dale, Jarrod; Bhargava, Puneet

    2013-01-01

    The use of computed tomography (CT) for evaluation of liver disease has increased dramatically at our tertiary care center due to increased hepatology referrals. We sought to decrease the radiation dose associated with multiphase liver CT studies while maintaining a high degree of diagnostic accuracy. We found that by eliminating the nonenhanced acquisition and adjusting the imaging field of view to include the liver-containing abdomen only-simply by manipulation of patient-specific imaging parameters-we achieved a 30% reduction in dose.

  18. Maltese CT doses for commonly performed examinations demonstrate alignment with published DRLs across Europe.

    PubMed

    Zarb, Francis; McEntee, Mark; Rainford, Louise

    2012-06-01

    This work recommends dose reference levels (DRLs) for abdomen, chest and head computerised tomography (CT) examinations in Malta as the first step towards national CT dose optimisation. Third quartiles volume CT dose index  values for abdomen: 12.1 mGy, chest: 13.1 mGy and head: 41 mGy and third quartile dose-length product values for abdomen: 539.4, chest: 492 and head: 736 mGy cm(-1) are recommended as Maltese DRLs derived from this first Maltese CT dose survey. These values compare well with DRLs of other European countries indicating that CT scanning in Malta is consistent with standards of good practice. Further work to minimise dose without affecting image quality and extending the establishment of DRLs for other CT examinations is recommended.

  19. Utilising pseudo-CT data for dose calculation and plan optimization in adaptive radiotherapy.

    PubMed

    Whelan, Brendan; Kumar, Shivani; Dowling, Jason; Begg, Jarrad; Lambert, Jonathan; Lim, Karen; Vinod, Shalini K; Greer, Peter B; Holloway, Lois

    2015-12-01

    To quantify the dose calculation error and resulting optimization uncertainty caused by performing inverse treatment planning on inaccurate electron density data (pseudo-CT) as needed for adaptive radiotherapy and Magnetic Resonance Imaging (MRI) based treatment planning. Planning Computer Tomography (CT) data from 10 cervix cancer patients was used to generate 4 pseudo-CT data sets. Each pseudo-CT was created based on an available method of assigning electron density to an anatomic image. An inversely modulated radiotherapy (IMRT) plan was developed on each planning CT. The dose calculation error caused by each pseudo-CT data set was quantified by comparing the dose calculated each pseudo-CT data set with that calculated on the original planning CT for the same IMRT plan. The optimization uncertainty introduced by the dose calculation error was quantified by re-optimizing the same optimization parameters on each pseudo-CT data set and comparing against the original planning CT. Dose differences were quantified by assessing the Equivalent Uniform Dose (EUD) for targets and relevant organs at risk. Across all pseudo-CT data sets and all organs, the absolute mean dose calculation error was 0.2 Gy, and was within 2 % of the prescription dose in 98.5 % of cases. Then absolute mean optimisation error was 0.3 Gy EUD, indicating that that inverse optimisation is impacted by the dose calculation error. However, the additional uncertainty introduced to plan optimisation is small compared the sources of variation which already exist. Use of inaccurate electron density data for inverse treatment planning results in a dose calculation error, which in turn introduces additional uncertainty into the plan optimization process. In this study, we showed that both of these effects are clinically acceptable for cervix cancer patients using four different pseudo-CT data sets. Dose calculation and inverse optimization on pseudo-CT is feasible for this patient cohort.

  20. Half-dose non-contrast CT in the investigation of urolithiasis: image quality improvement with third-generation integrated circuit CT detectors.

    PubMed

    Wang, Jun; Kang, Tony; Arepalli, Chesnal; Barrett, Sarah; O'Connell, Tim; Louis, Luck; Nicolaou, Savvakis; McLaughlin, Patrick

    2015-06-01

    The objective of this study is to establish the effect of third-generation integrated circuit (IC) CT detector on objective image quality in full- and half-dose non-contrast CT of the urinary tract. 51 consecutive patients with acute renal colic underwent non-contrast CT of the urinary tract using a 128-slice dual-source CT before (n = 24) and after (n = 27) the installation of third-generation IC detectors. Half-dose images were generated using projections from detector A using the dual-source RAW data. Objective image noise in the liver, spleen, right renal cortex, and right psoas muscle was compared between DC and IC cohorts for full-dose and half-dose images reconstructed with FBP and IR algorithms using 1 cm(2) regions of interest. Presence and size of obstructing ureteric calculi were also compared for full-dose and half-dose reconstructions using DC and IC detectors. No statistical difference in age and lateral body size was found between patients in the IC and DC cohorts. Radiation dose, as measured by size-specific dose estimates, did not differ significantly either between the two cohorts (10.02 ± 4.54 mGy IC vs. 12.28 ± 7.03 mGy DC). At full dose, objective image noise was not significantly lower in the IC cohort as compared to the DC cohort for the liver, spleen, and right psoas muscle. At half dose, objective image noise was lower in the IC cohort as compared to DC cohort at the liver (21.32 IC vs. 24.99 DC, 14.7% decrease, p < 0.001), spleen (19.33 IC vs. 20.83 DC, 7.20% decrease, p = 0.02), and right renal cortex (20.28 IC vs. 22.98 DC, 11.7% decrease, p = 0.005). Mean obstructing ureteric calculi size was not significantly different when comparison was made between full-dose and half-dose images, regardless of detector type (p > 0.05 for all comparisons). Third-generation IC detectors result in lower objective image noise at full- and half-radiation dose levels as compared with traditional DC detectors. The magnitude of noise reduction was greater

  1. Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom.

    PubMed

    Goren, A D; Prins, R D; Dauer, L T; Quinn, B; Al-Najjar, A; Faber, R D; Patchell, G; Branets, I; Colosi, D C

    2013-01-01

    This study aims to demonstrate the effectiveness of leaded glasses in reducing the lens of eye dose and of lead thyroid collars in reducing the dose to the thyroid gland of an adult female from dental cone beam CT (CBCT). The effect of collimation on the radiation dose in head organs is also examined. Dose measurements were conducted by placing optically stimulated luminescent dosemeters in an anthropomorphic female phantom. Eye lens dose was measured by placing a dosemeter on the anterior surface of the phantom eye location. All exposures were performed on one commercially available dental CBCT machine, using selected collimation and exposure techniques. Each scan technique was performed without any lead shielding and then repeated with lead shielding in place. To calculate the percent reduction from lead shielding, the dose measured with lead shielding was divided by the dose measured without lead shielding. The percent reduction from collimation was calculated by comparing the dose measured with collimation to the dose measured without collimation. The dose to the internal eye for one of the scans without leaded glasses or thyroid shield was 0.450 cGy and with glasses and thyroid shield was 0.116 cGy (a 74% reduction). The reduction to the lens of the eye was from 0.396 cGy to 0.153 cGy (a 61% reduction). Without glasses or thyroid shield, the thyroid dose was 0.158 cGy; and when both glasses and shield were used, the thyroid dose was reduced to 0.091 cGy (a 42% reduction). Collimation alone reduced the dose to the brain by up to 91%, with a similar reduction in other organs. Based on these data, leaded glasses, thyroid collars and collimation minimize the dose to organs outside the field of view.

  2. Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom

    PubMed Central

    Goren, AD; Prins, RD; Dauer, LT; Quinn, B; Al-Najjar, A; Faber, RD; Patchell, G; Branets, I; Colosi, DC

    2013-01-01

    Objectives: This study aims to demonstrate the effectiveness of leaded glasses in reducing the lens of eye dose and of lead thyroid collars in reducing the dose to the thyroid gland of an adult female from dental cone beam CT (CBCT). The effect of collimation on the radiation dose in head organs is also examined. Methods: Dose measurements were conducted by placing optically stimulated luminescent dosemeters in an anthropomorphic female phantom. Eye lens dose was measured by placing a dosemeter on the anterior surface of the phantom eye location. All exposures were performed on one commercially available dental CBCT machine, using selected collimation and exposure techniques. Each scan technique was performed without any lead shielding and then repeated with lead shielding in place. To calculate the percent reduction from lead shielding, the dose measured with lead shielding was divided by the dose measured without lead shielding. The percent reduction from collimation was calculated by comparing the dose measured with collimation to the dose measured without collimation. Results: The dose to the internal eye for one of the scans without leaded glasses or thyroid shield was 0.450 cGy and with glasses and thyroid shield was 0.116 cGy (a 74% reduction). The reduction to the lens of the eye was from 0.396 cGy to 0.153 cGy (a 61% reduction). Without glasses or thyroid shield, the thyroid dose was 0.158 cGy; and when both glasses and shield were used, the thyroid dose was reduced to 0.091 cGy (a 42% reduction). Conclusions: Collimation alone reduced the dose to the brain by up to 91%, with a similar reduction in other organs. Based on these data, leaded glasses, thyroid collars and collimation minimize the dose to organs outside the field of view. PMID:23412460

  3. Low-Dose PET/CT and Full-Dose Contrast-Enhanced CT at the Initial Staging of Localized Diffuse Large B-Cell Lymphomas

    PubMed Central

    Sabaté-Llobera, Aida; Cortés-Romera, Montserrat; Mercadal, Santiago; Hernández-Gañán, Javier; Pomares, Helena; González-Barca, Eva; Gámez-Cenzano, Cristina

    2016-01-01

    Computed tomography (CT) has been used as the reference imaging technique for the initial staging of diffuse large B-cell lymphoma until recent days, when the introduction of positron emission tomography (PET)/CT imaging as a hybrid technique has become of routine use. However, the performance of both examinations is still common. The aim of this work was to compare the findings between low-dose 2-deoxy-2-(18F)fluoro-d-glucose (18F-FDG) PET/CT and full-dose contrast-enhanced CT (ceCT) in 28 patients with localized diffuse large B-cell lymphoma according to PET/CT findings, in order to avoid the performance of ceCT. For each technique, a comparison in the number of nodal and extranodal involved regions was performed. PET/CT showed more lesions than ceCT in both nodal (41 vs. 36) and extranodal localizations (16 vs. 15). Disease staging according to both techniques was concordant in 22 patients (79%) and discordant in 6 patients (21%), changing treatment management in 3 patients (11%). PET/CT determined a better staging and therapeutic approach, making the performance of an additional ceCT unnecessary. PMID:27559300

  4. A knowledge-based iterative model reconstruction algorithm: can super-low-dose cardiac CT be applicable in clinical settings?

    PubMed

    Oda, Seitaro; Utsunomiya, Daisuke; Funama, Yoshinori; Katahira, Kazuhiro; Honda, Keiichi; Tokuyasu, Shinichi; Vembar, Mani; Yuki, Hideaki; Noda, Katsuo; Oshima, Shuichi; Yamashita, Yasuyuki

    2014-01-01

    To investigate whether "full" iterative reconstruction, a knowledge-based iterative model reconstruction (IMR), enables radiation dose reduction by 80% at cardiac computed tomography (CT). A total of 23 patients (15 men, eight women; mean age 64.3 ± 13.4 years) who underwent retrospectively electrocardiography-gated cardiac CT with dose modulation were evaluated. We compared full-dose (FD; 730 mAs) images reconstructed with filtered back projection (FBP) technique and the low-dose (LD; 146 mAs) images reconstructed with FBP and IMR techniques. Objective and subjective image quality parameters were compared among the three different CT images. There was no significant difference in the CT attenuation among the three reconstructions. The mean image noise of LD-IMR (18.3 ± 10.6 Hounsfield units [HU]) was significantly lowest among the three reconstructions (41.9 ± 15.3 HU for FD-FBP and 109.9 ± 42.6 HU for LD-FBP; P < .01). The contrast-to-noise ratio of LD-IMR was better than that of FD-FBP and LD-FBP (P < .01). Visual evaluation score was also highest for LD-IMR. The IMR can provide improved image quality at super-low-dose cardiac CT with 20% of the standard tube current. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  5. Does Real-Time Monitoring of Patient Dose With Dose Management Software Increase CT Technologists' Radiation Awareness?

    PubMed

    Heilmaier, Christina; Zuber, Niklaus; Bruijns, Bernardus; Weishaupt, Dominik

    2016-05-01

    Dose management software can be used to increase patient safety. The purpose of the current study was to evaluate whether real-time monitoring of patient dose in CT examinations increases CT technologists' dose awareness. Dose data of two scanners (clinical routine CT scanner, mainly outpatients; emergency CT scanner, predominantly emergency department and ICU patients) were analyzed before (period 1) and after (period 2) dose management software was implemented in clinical routine and technologists were advised to check for dose notifications (dose values above reference levels) after each examination (i.e., real-time monitoring). To assess statistically significant differences between both the scanners and the study periods, we used chi-square tests. A total of 6413 examinations were performed (period 1 = 3214 examinations, period 2 = 3199 examinations). Dose notifications were mainly because of patient miscentering (period 1 = 45% of examinations, period 2 = 23%), overweight patients (period 1 = 35%, period 2 = 49%), and scanning repetition (period 1 = 10%, period 2 = 15%). Overall, the number of dose notifications significantly declined in period 2 (period 1, n = 210; period 2, n = 120; p < 0.001). Miscentering was more often seen on the clinical routine CT examinations (period 1 = 46%, period 2 = 23%) than on the emergency CT examinations (period 1 = 44%, period 2 = 22%) and occurred significantly less frequently on both scanners in period 2 (period 1: n = 94; period 2: n = 27; p < 0.001). The relative values of dose notifications due to overweight patients or scanning repetition were higher in period 2, but these differences did not reach statistical significance (p > 0.05). Real-time monitoring of patient dose with dose management software increases CT technologists' dose awareness and leads to a reduced number of dose notifications due to human error.

  6. Novel iterative reconstruction method with optimal dose usage for partially redundant CT-acquisition

    NASA Astrophysics Data System (ADS)

    Bruder, H.; Raupach, R.; Sunnegardh, J.; Allmendinger, T.; Klotz, E.; Stierstorfer, K.; Flohr, T.

    2015-11-01

    In CT imaging, a variety of applications exist which are strongly SNR limited. However, in some cases redundant data of the same body region provide additional quanta. Examples: in dual energy CT, the spatial resolution has to be compromised to provide good SNR for material decomposition. However, the respective spectral dataset of the same body region provides additional quanta which might be utilized to improve SNR of each spectral component. Perfusion CT is a high dose application, and dose reduction is highly desirable. However, a meaningful evaluation of perfusion parameters might be impaired by noisy time frames. On the other hand, the SNR of the average of all time frames is extremely high. In redundant CT acquisitions, multiple image datasets can be reconstructed and averaged to composite image data. These composite image data, however, might be compromised with respect to contrast resolution and/or spatial resolution and/or temporal resolution. These observations bring us to the idea of transferring high SNR of composite image data to low SNR ‘source’ image data, while maintaining their resolution. It has been shown that the noise characteristics of CT image data can be improved by iterative reconstruction (Popescu et al 2012 Book of Abstracts, 2nd CT Meeting (Salt Lake City, UT) p 148). In case of data dependent Gaussian noise it can be modelled with image-based iterative reconstruction at least in an approximate manner (Bruder et al 2011 Proc. SPIE 7961 79610J). We present a generalized update equation in image space, consisting of a linear combination of the previous update, a correction term which is constrained by the source image data, and a regularization prior, which is initialized by the composite image data. This iterative reconstruction approach we call bimodal reconstruction (BMR). Based on simulation data it is shown that BMR can improve low contrast detectability, substantially reduces the noise power and has the potential to recover

  7. Novel iterative reconstruction method with optimal dose usage for partially redundant CT-acquisition.

    PubMed

    Bruder, H; Raupach, R; Sunnegardh, J; Allmendinger, T; Klotz, E; Stierstorfer, K; Flohr, T

    2015-11-07

    In CT imaging, a variety of applications exist which are strongly SNR limited. However, in some cases redundant data of the same body region provide additional quanta. Examples in dual energy CT, the spatial resolution has to be compromised to provide good SNR for material decomposition. However, the respective spectral dataset of the same body region provides additional quanta which might be utilized to improve SNR of each spectral component. Perfusion CT is a high dose application, and dose reduction is highly desirable. However, a meaningful evaluation of perfusion parameters might be impaired by noisy time frames. On the other hand, the SNR of the average of all time frames is extremely high.In redundant CT acquisitions, multiple image datasets can be reconstructed and averaged to composite image data. These composite image data, however, might be compromised with respect to contrast resolution and/or spatial resolution and/or temporal resolution. These observations bring us to the idea of transferring high SNR of composite image data to low SNR 'source' image data, while maintaining their resolution.It has been shown that the noise characteristics of CT image data can be improved by iterative reconstruction (Popescu et al 2012 Book of Abstracts, 2nd CT Meeting (Salt Lake City, UT) p 148). In case of data dependent Gaussian noise it can be modelled with image-based iterative reconstruction at least in an approximate manner (Bruder et al 2011 Proc. SPIE 7961 79610J). We present a generalized update equation in image space, consisting of a linear combination of the previous update, a correction term which is constrained by the source image data, and a regularization prior, which is initialized by the composite image data. This iterative reconstruction approach we call bimodal reconstruction (BMR). Based on simulation data it is shown that BMR can improve low contrast detectability, substantially reduces the noise power and has the potential to recover spatial

  8. Radiation Dose Consideration in Kidney Stone CT Examinations: Integration of Iterative Reconstruction Algorithms With Routine Clinical Practice.

    PubMed

    Andrabi, Yasir; Pianykh, Oleg; Agrawal, Mukta; Kambadakone, Avinash; Blake, Michael A; Sahani, Dushyant V

    2015-05-01

    1.9 mGy; SAFIRE, 7.6 ± 3.2 mGy) (p > 0.05). The three IRs enable 20-33% radiation dose reduction in kidney stone CT examinations compared with the FBP technique without any image quality concerns. The radiation dose and image quality were comparable among these three IR algorithms.

  9. ASSESSMENT OF EFFECTIVE DOSE FROM CONE BEAM CT IMAGING IN SPECT/CT EXAMINATION IN COMPARISON WITH OTHER MODALITIES.

    PubMed

    Tonkopi, Elena; Ross, Andrew A

    2016-12-01

    The aim of this study was to assess radiation dose from the cone beam computed tomography (CBCT) component of single photon emission tomography/computed tomography (SPECT/CT) examinations and to compare it with the radiopharmaceutical related dose as well as dose from multidetector computed tomography (MDCT). Effective dose (ED) from computed tomography (CT) was estimated using dose-length product values and anatomy-specific conversion factors. The contribution from the SPECT component was evaluated using ED per unit administered activity for the radiopharmaceuticals listed in the International Commission on Radiological Protection Publications 80 and 106. With the exception of cardiac studies (0.11 mSv), the CBCT dose (3.96-6.04 mSv) was similar to that from the radiopharmaceutical accounting for 29-56 % of the total ED from the examination. In comparison with MDCT examinations, the CBCT dose was 48 and 42 % lower for abdomen/pelvis and chest/abdomen/pelvis scans, respectively, while in the chest the CBCT scan resulted in higher dose (23 %). Radiation dose from the CT component should be taken into consideration when evaluating total SPECT/CT patient dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Slowing the increase in the population dose resulting from CT scans.

    PubMed

    Brenner, D J

    2010-12-01

    The annual number of CT scans in the U.S. is now over 70 million. The concern is that organ doses from CT are typically far larger than those from conventional X-ray examinations, and there is epidemiological evidence of a small but significant increased cancer risk at typical CT doses. Because CT is a superb diagnostic tool and because individual CT risks are small, when a CT scan is clinically indicated, the CT benefit/risk balance is by far in the patient's favor. Nevertheless, CT should operate under the ALARA (As Low As Reasonably Achievable) principle, and opportunities exist to reduce the significant population dose associated with CT without compromising patient care. The first opportunity is to reduce the dose per scan, and improved technology has much potential here. The second opportunity is selective replacement of CT with other modalities, such as for many head and spinal examinations (with MRI), and for diagnosing appendicitis (selective use of ultrasound + CT). Finally, a fraction of CT scans could be avoided entirely, as indicated by CT decision rules: Clinical decision rules for CT use represent a powerful approach for slowing down the increase in CT use, because they have the potential to overcome some of the major factors that result in some CT scans being undertaken when they are potentially not clinically helpful. In the U.S. and potentially elsewhere, legislative approaches are a possible option, to improve quality control and reduce clinically unneeded CT use, and it is also possible that upcoming changes in heath care economics will tend to slow the increase in such CT use.

  11. Metal artifact reduction in CT via ray profile correction

    NASA Astrophysics Data System (ADS)

    Ha, Sungsoo; Mueller, Klaus

    2016-03-01

    In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear assumption made by the analytical CT reconstruction algorithm. The inconsistencies appear in the form of dark and bright bands and streaks in the reconstructed image, collectively called metal artifacts. The standard method for metal artifact reduction (MAR) replaces the inconsistent data with the interpolated data. However, sinogram interpolation not only introduces new artifacts but it also suffers from the loss of detail near the implanted metals. With the help of a prior image that is usually estimated from the metal artifact-degraded image via computer vision techniques, improvements are feasible but still no MAR method exists that is widely accepted and utilized. We propose a technique that utilizes a prior image from a CT scan taken of the patient before implanting the metal objects. Hence there is a sufficient amount of structural similarity to cover the loss of detail around the metal implants. Using the prior scan and a segmentation or model of the metal implant our method then replaces sinogram interpolation with ray profile matching and estimation which yields much more reliable data estimates for the affected sinogram regions. As preliminary work, we built a new MAR framework on fan-beam geometry and tested it to remove simulated metal artifacts on a thorax phantom. The comparison with two representative sinogram correction based MAR methods shows very promising results.

  12. Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy

    SciTech Connect

    Axente, Marian; Von Eyben, Rie; Hristov, Dimitre; Paidi, Ajay; Bani-Hashemi, Ali; Zeng, Chuan; Krauss, Andreas

    2015-03-15

    Purpose: To clinically evaluate an iterative metal artifact reduction (IMAR) algorithm prototype in the radiation oncology clinic setting by testing for accuracy in CT number retrieval, relative dosimetric changes in regions affected by artifacts, and improvements in anatomical and shape conspicuity of corrected images. Methods: A phantom with known material inserts was scanned in the presence/absence of metal with different configurations of placement and sizes. The relative change in CT numbers from the reference data (CT with no metal) was analyzed. The CT studies were also used for dosimetric tests where dose distributions from both photon and proton beams were calculated. Dose differences and gamma analysis were calculated to quantify the relative changes between doses calculated on the different CT studies. Data from eight patients (all different treatment sites) were also used to quantify the differences between dose distributions before and after correction with IMAR, with no reference standard. A ranking experiment was also conducted to analyze the relative confidence of physicians delineating anatomy in the near vicinity of the metal implants. Results: IMAR corrected images proved to accurately retrieve CT numbers in the phantom study, independent of metal insert configuration, size of the metal, and acquisition energy. For plastic water, the mean difference between corrected images and reference images was −1.3 HU across all scenarios (N = 37) with a 90% confidence interval of [−2.4, −0.2] HU. While deviations were relatively higher in images with more metal content, IMAR was able to effectively correct the CT numbers independent of the quantity of metal. Residual errors in the CT numbers as well as some induced by the correction algorithm were found in the IMAR corrected images. However, the dose distributions calculated on IMAR corrected images were closer to the reference data in phantom studies. Relative spatial difference in the dose

  13. Changes realized from extended bit-depth and metal artifact reduction in CT

    SciTech Connect

    Glide-Hurst, C.; Chen, D.; Zhong, H.; Chetty, I. J.

    2013-06-15

    Purpose: High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosimetry. Methods: Extended CT to electron density (CT-ED) curves were derived from a tissue characterization phantom with titanium and stainless steel inserts scanned at 90-140 kVp for 12- and 16-bit reconstructions. MAR was applied to sinogram data (Brilliance BigBore CT scanner, Philips Healthcare, v.3.5). Monte Carlo simulation (MC-SIM) was performed on a simulated double hip prostheses case (Cerrobend rods embedded in a pelvic phantom) using BEAMnrc/Dosxyz (400 000 0000 histories, 6X, 10 Multiplication-Sign 10 cm{sup 2} beam traversing Cerrobend rod). A phantom study was also conducted using a stainless steel rod embedded in solid water, and dosimetric verification was performed with Gafchromic film analysis (absolute difference and gamma analysis, 2% dose and 2 mm distance to agreement) for plans calculated with Anisotropic Analytic Algorithm (AAA, Eclipse v11.0) to elucidate changes between 12- and 16-bit data. Three patients (bony metastases to the femur and humerus, and a prostate cancer case) with metal implants were reconstructed using both bit depths, with dose calculated using AAA and derived CT-ED curves. Planar dose distributions were assessed via matrix analyses and using gamma criteria of 2%/2 mm. Results: For 12-bit images, CT numbers for titanium and stainless steel saturated at 3071 Hounsfield units (HU), whereas for 16-bit depth, mean CT numbers were much larger (e.g., titanium and stainless steel yielded HU of 8066.5 {+-} 56.6 and 13 588.5 {+-} 198.8 for 16-bit uncorrected scans at 120 kVp, respectively). MC-SIM was well-matched between 12- and 16-bit images except downstream of the Cerrobend rod, where 16-bit dose was {approx}6

  14. Phantom based evaluation of CT to CBCT image registration for proton therapy dose recalculation

    NASA Astrophysics Data System (ADS)

    Landry, Guillaume; Dedes, George; Zöllner, Christoph; Handrack, Josefine; Janssens, Guillaume; Orban de Xivry, Jonathan; Reiner, Michael; Paganelli, Chiara; Riboldi, Marco; Kamp, Florian; Söhn, Matthias; Wilkens, Jan J.; Baroni, Guido; Belka, Claus; Parodi, Katia

    2015-01-01

    The ability to perform dose recalculation on the anatomy of the day is important in the context of adaptive proton therapy. The objective of this study was to investigate the use of deformable image registration (DIR) and cone beam CT (CBCT) imaging to generate the daily stopping power distribution of the patient. We investigated the deformation of the planning CT scan (pCT) onto daily CBCT images to generate a virtual CT (vCT) using a deformable phantom designed for the head and neck (H & N) region. The phantom was imaged at a planning CT scanner in planning configuration, yielding a pCT and in deformed, treatment day configuration, yielding a reference CT (refCT). The treatment day configuration was additionally scanned at a CBCT scanner. A Morphons DIR algorithm was used to generate a vCT. The accuracy of the vCT was evaluated by comparison to the refCT in terms of corresponding features as identified by an adaptive scale invariant feature transform (aSIFT) algorithm. Additionally, the vCT CT numbers were compared to those of the refCT using both profiles and regions of interest and the volumes and overlap (DICE coefficients) of various phantom structures were compared. The water equivalent thickness (WET) of the vCT, refCT and pCT were also compared to evaluate proton range differences. Proton dose distributions from the same initial fluence were calculated on the refCT, vCT and pCT and compared in terms of proton range. The method was tested on a clinical dataset using a replanning CT scan acquired close in time to a CBCT scan as reference using the WET evaluation. Results from the aSIFT investigation suggest a deformation accuracy of 2-3 mm. The use of the Morphon algorithm did not distort CT number intensity in uniform regions and WET differences between vCT and refCT were of the order of 2% of the proton range. This result was confirmed by proton dose calculations. The patient results were consistent with phantom observations. In conclusion, our phantom

  15. Measurement of CT scanner dose profiles in a filmless department.

    PubMed

    Thomson, F J

    2005-09-01

    The measurement of the FWHM of the slice thickness radiation dose profile of a CT scanner using a prototype low sensitivity CR imaging plate has been investigated, as an alternative to the traditional method using envelope-packed industrial film. Using a standard Agfa clinical CR system to acquire the image, the FWHM of the dose profile can be accurately measured using readily available Public Domain software. An Agfa 18 x 24 cm CR cassette gives a pixel pitch of 113.5 microm, but with interpolation, the measurement accuracy can be less than 1 pixel. For a nominal 10 mm collimation, 15 successive measurements of the FWHM using CR gave an average width of 10.00 mm with a standard deviation of 0.02 mm. This may be compared with 4 successive measurements using film and a dual exposure technique to define the optical density at half peak height, yielding an average width of 9.98 mm with a SD of 0.03 mm. This prototype NDT plate is not a commercial product, but a radiotherapy plate with a similar sensitivity is available commercially and should give similar results.

  16. FDG-PET/CT during concomitant chemo radiotherapy for esophageal cancer: Reducing target volumes to deliver higher radiotherapy doses.

    PubMed

    Nkhali, Lamyaa; Thureau, Sébastien; Edet-Sanson, Agathe; Doyeux, Kaya; Benyoucef, Ahmed; Gardin, Isabelle; Michel, Pierre; Vera, Pierre; Dubray, Bernard

    2015-06-01

    A planning study investigated whether reduced target volumes defined on FDG-PET/CT during radiotherapy allow total dose escalation without compromising normal tissue tolerance in patients with esophageal cancer. Ten patients with esophageal squamous cell carcinoma (SCC), candidate to curative-intent concomitant chemo-radiotherapy (CRT), had FDG-PET/CT performed in treatment position, before and during (Day 21) radiotherapy (RT). Four planning scenarios were investigated: 1) 50 Gy total dose with target volumes defined on pre-RT FDG-PET/CT; 2) 50 Gy with boost target volume defined on FDG-PET/CT during RT; 3) 66 Gy with target volumes from pre-RT FDG-PET/CT; and 4) 66 Gy with boost target volume from during-RT FDG-PET/CT. The median metabolic target volume decreased from 12.9 cm3 (minimum 3.7-maximum 44.8) to 5.0 cm3 (1.7-13.5) (p=0.01) between pre- and during-RCT FDG-PET/CT. The median PTV66 was smaller on during-RT than on baseline FDG-PET/CT [108 cm3 (62.5-194) vs. 156 cm3 (68.8-251), p=0.02]. When total dose was set to 50 Gy, planning on during-RT FDG-PET/CT was associated with a marginal reduction in normal tissues irradiation. When total dose was increased to 66 Gy, planning on during-RT PET yielded significantly lower doses to the spinal cord [Dmax=44.1Gy (40.8-44.9) vs. 44.7Gy (41.5-45.0), p=0.007] and reduced lung exposure [V20Gy=23.2% (17.3-27) vs. 26.8% (19.7-30.2), p=0.006]. This planning study suggests that adaptive RT based on target volume reduction assessed on FDG-PET/CT during treatment could facilitate dose escalation up to 66 Gy in patients with esophageal SCC.

  17. Quality and Dose Optimized CT Trauma Protocol - Recommendation from a University Level-I Trauma Center.

    PubMed

    Kahn, Johannes; Kaul, David; Böning, Georg; Rotzinger, Roman; Freyhardt, Patrick; Schwabe, Philipp; Maurer, Martin H; Renz, Diane Miriam; Streitparth, Florian

    2017-09-01

    Purpose As a supra-regional level-I trauma center, we evaluated computed tomography (CT) acquisitions of polytraumatized patients for quality and dose optimization purposes. Adapted statistical iterative reconstruction [(AS)IR] levels, tube voltage reduction as well as a split-bolus contrast agent (CA) protocol were applied. Materials and Methods 61 patients were split into 3 different groups that differed with respect to tube voltage (120 - 140 kVp) and level of applied ASIR reconstruction (ASIR 20 - 50 %). The CT protocol included a native acquisition of the head followed by a single contrast-enhanced acquisition of the whole body (64-MSCT). CA (350 mg/ml iodine) was administered as a split bolus injection of 100 ml (2 ml/s), 20 ml NaCl (1 ml/s), 60 ml (4 ml/s), 40 ml NaCl (4 ml/s) with a scan delay of 85 s to detect injuries of both the arterial system and parenchymal organs in a single acquisition. Both the quantitative (SNR/CNR) and qualitative (5-point Likert scale) image quality was evaluated in parenchymal organs that are often injured in trauma patients. Radiation exposure was assessed. Results The use of IR combined with a reduction of tube voltage resulted in good qualitative and quantitative image quality and a significant reduction in radiation exposure of more than 40 % (DLP 1087 vs. 647 mGyxcm). Image quality could be improved due to a dedicated protocol that included different levels of IR adapted to different slice thicknesses, kernels and the examined area for the evaluation of head, lung, body and bone injury patterns. In synopsis of our results, we recommend the implementation of a polytrauma protocol with a tube voltage of 120 kVp and the following IR levels: cCT 5mm: ASIR 20; cCT 0.625 mm: ASIR 40; lung 2.5 mm: ASIR 30, body 5 mm: ASIR 40; body 1.25 mm: ASIR 50; body 0.625 mm: ASIR 0. Conclusion A dedicated adaptation of the CT trauma protocol (level of reduction of tube voltage and of IR

  18. Task-based image quality evaluation of iterative reconstruction methods for low dose CT using computer simulations

    NASA Astrophysics Data System (ADS)

    Xu, Jingyan; Fuld, Matthew K.; Fung, George S. K.; Tsui, Benjamin M. W.

    2015-04-01

    Iterative reconstruction (IR) methods for x-ray CT is a promising approach to improve image quality or reduce radiation dose to patients. The goal of this work was to use task based image quality measures and the channelized Hotelling observer (CHO) to evaluate both analytic and IR methods for clinical x-ray CT applications. We performed realistic computer simulations at five radiation dose levels, from a clinical reference low dose D0 to 25% D0. A fixed size and contrast lesion was inserted at different locations into the liver of the XCAT phantom to simulate a weak signal. The simulated data were reconstructed on a commercial CT scanner (SOMATOM Definition Flash; Siemens, Forchheim, Germany) using the vendor-provided analytic (WFBP) and IR (SAFIRE) methods. The reconstructed images were analyzed by CHOs with both rotationally symmetric (RS) and rotationally oriented (RO) channels, and with different numbers of lesion locations (5, 10, and 20) in a signal known exactly (SKE), background known exactly but variable (BKEV) detection task. The area under the receiver operating characteristic curve (AUC) was used as a summary measure to compare the IR and analytic methods; the AUC was also used as the equal performance criterion to derive the potential dose reduction factor of IR. In general, there was a good agreement in the relative AUC values of different reconstruction methods using CHOs with RS and RO channels, although the CHO with RO channels achieved higher AUCs than RS channels. The improvement of IR over analytic methods depends on the dose level. The reference dose level D0 was based on a clinical low dose protocol, lower than the standard dose due to the use of IR methods. At 75% D0, the performance improvement was statistically significant (p < 0.05). The potential dose reduction factor also depended on the detection task. For the SKE/BKEV task involving 10 lesion locations, a dose reduction of at least 25% from D0 was achieved.

  19. Radiation dose exposure for lumbar spine epidural steroid injections: a comparison of conventional fluoroscopy data and CT fluoroscopy techniques.

    PubMed

    Hoang, Jenny K; Yoshizumi, Terry T; Toncheva, Greta; Gray, Linda; Gafton, Andreia R; Huh, Billy K; Eastwood, James D; Lascola, Christopher D; Hurwitz, Lynne M

    2011-10-01

    The purpose of this article is to compare the radiation dose of conventional fluoroscopy-guided lumbar epidural steroid injections (ESIs) and CT fluoroscopy (CTF)-guided lumbar ESI using both clinical data and anthropomorphic phantoms. We performed a retrospective review of dose parameters for 14 conventional fluoroscopy ESI procedures performed by one proceduralist and 42 CTF-guided ESIs performed by three proceduralists (14 each). By use of imaging techniques similar to those for our clinical cohorts, a commercially available anthropomorphic male phantom with metal oxide semiconductor field effect transistor detectors was scanned to obtain absorbed organ doses for conventional fluoroscopy-guided and CTF-guided ESIs. Effective dose (ED) was calculated from measured organ doses. The mean conventional fluoroscopy time for ESI was 37 seconds, and the mean procedural CTF time was 4.7 seconds. Calculated ED for conventional fluoroscopy was 0.85 mSv compared with 0.45 mSv for CTF. The greatest contribution to the radiation dose from CTF-guided ESI came from the planning lumbar spine CT scan, which had an ED of 2.90 mSv when z-axis ranged from L2 to S1. This resulted in a total ED for CTF-guided ESI (lumbar spine CT scan plus CTF) of 3.35 mSv. The ED for the CTF-guided ESI was almost half that of conventional fluoroscopy because of the shorter fluoroscopy time. However, the overall radiation dose for CTF-guided ESIs can be up to four times higher when a full diagnostic lumbar CT scan is performed as part of the procedure. Radiation dose reduction for CTF-guided ESI is best achieved by minimizing the dose from the preliminary planning lumbar spine CT scan.

  20. Potential for radiation dose savings in abdominal and chest CT using automatic tube voltage selection in combination with automatic tube current modulation.

    PubMed

    Mayer, Caroline; Meyer, Mathias; Fink, Christian; Schmidt, Bernhard; Sedlmair, Martin; Schoenberg, Stefan O; Henzler, Thomas

    2014-08-01

    The purpose of this study was to evaluate the simultaneous use of automatic tube current modulation (ATCM) and automatic tube voltage selection (ATVS) for abdominal and chest CT examinations regarding radiation dose reduction and image quality. We enrolled 617 patients who all underwent contrast-enhanced chest or abdominal CT and divided them into two groups. In group A, 317 patients who underwent CT with only ATCM and a fixed body mass index-adjusted tube voltage (120 kV or 100 kV) were enrolled. In group B, both ATCM and ATVS were used. Image attenuation and noise were measured in different anatomic regions. The mean contrast-to-noise ratio and the signal-to-noise ratio of abdomen and chest CT was higher in group B compared with group A (p < 0.0001). In total, the effective radiation doses for abdomen and chest CT examinations were significantly reduced in group B by 18% compared with group A (p < 0.0001). When only examining those who benefited from the ATVS tool, a dose reduction of 35% for chest CT and 42% for abdomen CT could be achieved (p < 0.0001 for each). The simultaneous use of ATVS and ATCM enables significant radiation dose reduction in abdominal and thoracic contrast-enhanced CT examinations compared with the use of ATCM alone.

  1. Low Dose CT Filtering in the Image Domain Using MAP Algorithms

    NASA Astrophysics Data System (ADS)

    Geraldo, Rafael J.; Cura, Luis M. V.; Cruvinel, Paulo E.; Mascarenhas, Nelson D. A.

    2017-06-01

    The purpose of this paper is to present two new noise reduction filters techniques in the CT image space, in order to provide a better quality to the images acquired with low radiation exposure. For the noise reduction, a new denoising technique is presented based on a pointwise Maximum a Posteriori (MAP). The noise is considered Gaussian with zero mean, as observed experimentally, and the variance is estimated considering a signal-independent noise. For the a priori density of the signal, we used different non-negative probability densities (reflecting the fact that the pixels of an image are non-negative). In another approach, the histogram of the images were segmented into unimodal parts and each segment was filtered using the filter based on the MAP criterion with the a priori density that best fits it. After filtering, the evaluation of the method is performed using the following criteria: Peak Signal-to-Noise Ratio, Universal Image Quality Index and Structural Similarity Index. The 2D filtering results are compared with the results obtained by pointwise Wiener filter. Simulation and real CT images results show that the proposed techniques increase the image quality and improve the use of a low-dose CT protocol.

  2. Progressive cone beam CT dose control in image-guided radiation therapy

    PubMed Central

    Yan, Hao; Zhen, Xin; Cerviño, Laura; Jiang, Steve B.; Jia, Xun

    2013-01-01

    Purpose: Cone beam CT (CBCT) in image-guided radiotherapy (IGRT) offers a tremendous advantage for treatment guidance. The associated imaging dose is a clinical concern. One unique feature of CBCT-based IGRT is that the same patient is repeatedly scanned during a treatment course, and the contents of CBCT images at different fractions are similar. The authors propose a progressive dose control (PDC) scheme to utilize this temporal correlation for imaging dose reduction. Methods: A dynamic CBCT scan protocol, as opposed to the static one in the current clinical practice, is proposed to gradually reduce the imaging dose in each treatment fraction. The CBCT image from each fraction is processed by a prior-image based nonlocal means (PINLM) module to enhance its quality. The increasing amount of prior information from previous CBCT images prevents degradation of image quality due to the reduced imaging dose. Two proof-of-principle experiments have been conducted using measured phantom data and Monte Carlo simulated patient data with deformation. Results: In the measured phantom case, utilizing a prior image acquired at 0.4 mAs, PINLM is able to improve the image quality of a CBCT acquired at 0.2 mAs by reducing the noise level from 34.95 to 12.45 HU. In the synthetic patient case, acceptable image quality is maintained at four consecutive fractions with gradually decreasing exposure levels of 0.4, 0.1, 0.07, and 0.05 mAs. When compared with the standard low-dose protocol of 0.4 mAs for each fraction, an overall imaging dose reduction of more than 60% is achieved. Conclusions: PINLM-PDC is able to reduce CBCT imaging dose in IGRT utilizing the temporal correlations among the sequence of CBCT images while maintaining the quality. PMID:23718579

  3. RADIANCE: An automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates.

    PubMed

    Cook, Tessa S; Zimmerman, Stefan L; Steingall, Scott R; Maidment, Andrew D A; Kim, Woojin; Boonn, William W

    2011-01-01

    There is growing interest in the ability to monitor, track, and report exposure to radiation from medical imaging. Historically, however, dose information has been stored on an image-based dose sheet, an arrangement that precludes widespread indexing. Although scanner manufacturers are beginning to include dose-related parameters in the Digital Imaging and Communications in Medicine (DICOM) headers of imaging studies, there remains a vast repository of retrospective computed tomographic (CT) data with image-based dose sheets. Consequently, it is difficult for imaging centers to monitor their dose estimates or participate in the American College of Radiology (ACR) Dose Index Registry. An automated extraction software pipeline known as Radiation Dose Intelligent Analytics for CT Examinations (RADIANCE) has been designed that quickly and accurately parses CT dose sheets to extract and archive dose-related parameters. Optical character recognition of information in the dose sheet leads to creation of a text file, which along with the DICOM study header is parsed to extract dose-related data. The data are then stored in a relational database that can be queried for dose monitoring and report creation. RADIANCE allows efficient dose analysis of CT examinations and more effective education of technologists, radiologists, and referring physicians regarding patient exposure to radiation at CT. RADIANCE also allows compliance with the ACR's dose reporting guidelines and greater awareness of patient radiation dose, ultimately resulting in improved patient care and treatment.

  4. A Survey of Radiation Doses in CT Urography Before and After Implementation of Iterative Reconstruction.

    PubMed

    van der Molen, Aart J; Miclea, Razvan L; Geleijns, Jacob; Joemai, Raoul M S

    2015-09-01

    The purpose of this study was to survey the radiation dose used in CT urography (CTU) in routine clinical practice, both before and after implementation of a scanning protocol that uses iterative reconstruction (Adaptive Iterative Dose Reduction 3D [AIDR 3D]). We retrospectively surveyed dose reports from consecutive CTU examinations performed in 2011 with the use of 64- and 320-MDCT scanners that were reconstructed with filtered back projection (FBP) and from CTU examinations performed from May 2012 through November 2013 that were reconstructed with the use of AIDR 3D. Findings from these dose reports were then correlated with such patient characteristics as weight and body mass index (BMI; weight in kilograms divided by the square of height in meters). Only dose reports from single-bolus three-phase CTU examinations were included in the study. The volume CT dose index, dose-length product (DLP), and effective dose were surveyed both per examination and per phase by use of published effective dose DLP conversion factors. Image quality was evaluated subjectively for a subset of patients. The two study cohorts included 82 patients (median patient weight, 75.0 kg; median BMI, 25.3) who underwent CTU with FBP and 85 patients (median patient weight, 78.0 kg; median BMI, 24.5) who underwent CTU with AIDR 3D. The median total DLP and median effective dose were 924 mGy · cm and 13.0 mSv, respectively, in the CTU with the FBP cohort and 433 mGy · cm and 6.1 mSv, respectively, in the CTU with the AIDR 3D cohort. The median DLP in the unenhanced, nephrogenic, and excretory phases was 218, 300, and 441 mGy · cm, respectively, in patients undergoing CTU with FBP and 114, 121, and 190 mGy · cm, respectively, in patients undergoing CTU with AIDR 3D. Image quality was diagnostic in both groups, with relatively fewer artifacts noted on scans obtained using CTU with AIDR 3D. Our study presents detailed dose data from three-phase CTU examinations performed both before and after

  5. SU-E-T-396: Dosimetric Accuracy of Proton Therapy for Patients with Metal Implants in CT Scans Using Metal Deletion Technique (MDT) Artifacts Reduction

    SciTech Connect

    Li, X; Kantor, M; Zhu, X; Frank, S; Sahoo, N; Li, H

    2014-06-01

    Purpose: To evaluate the dosimetric accuracy for proton therapy patients with metal implants in CT using metal deletion technique (MDT) artifacts reduction. Methods: Proton dose accuracies under CT metal artifacts were first evaluated using a water phantom with cylindrical inserts of different materials (titanium and steel). Ranges and dose profiles along different beam angles were calculated using treatment planning system (Eclipse version 8.9) on uncorrected CT, MDT CT, and manually-corrected CT, where true Hounsfield units (water) were assigned to the streak artifacts. In patient studies, the treatment plans were developed on manually-corrected CTs, then recalculated on MDT and uncorrected CTs. DVH indices were compared between the dose distributions on all the CTs. Results: For water phantom study with 1/2 inch titanium insert, the proton range differences estimated by MDT CT were with 1% for all beam angles, while the range error can be up to 2.6% for uncorrected CT. For the study with 1 inch stainless steel insert, the maximum range error calculated by MDT CT was 1.09% among all the beam angles compared with maximum range error with 4.7% for uncorrected CT. The dose profiles calculated on MDT CTs for both titanium and steel inserts showed very good agreements with the ones calculated on manually-corrected CTs, while large dose discrepancies calculated using uncorrected CTs were observed in the distal end region of the proton beam. The patient study showed similar dose distribution and DVHs for organs near the metal artifacts recalculated on MDT CT compared with the ones calculated on manually-corrected CT, while the differences between uncorrected and corrected CTs were much pronounced. Conclusion: In proton therapy, large dose error could occur due to metal artifact. The MDT CT can be used for proton dose calculation to achieve similar dose accuracy as the current clinical practice using manual correction.

  6. Optimization of radiation dose reduction in cardiac computed tomographic angiography.

    PubMed

    Entrikin, Daniel W; Leipsic, Jonathon A; Carr, J Jeffrey

    2011-01-01

    Cardiac computed tomographic angiography (CCTA) has evolved at an unprecedented pace over the past decade, during which time it has proven to be an accurate and effective tool for imaging of the heart in a growing list of clinical applications. However, the rapid growth in the use of CT imaging in general has prompted appropriate concerns regarding increasing medical radiation exposure to patients, particularly with regard to potential long-term risks of radiation-induced malignancy on both individual and population levels. As with all medical imaging modalities, imaging the heart with CCTA should be performed in a manner that achieves diagnostic image quality while maintaining patient radiation exposure as low as reasonably achievable (As Low As Reasonably Achievable [ALARA] principle). The goal of this article is to provide the reader with a wide-ranging review of both primary and secondary techniques that are currently available to minimize patient radiation exposure. Some of the techniques described in this article are universal, whereas others may be scanner specific. By gaining a thorough understanding of the various tools and methodologies employed for reduction of radiation exposure, the cardiac imager should be able to formulate CCTA protocols appropriate for their equipment and their clinical applications, in a manner that optimally preserves diagnostic image quality and minimizes patient radiation dose.

  7. The Effects of Metal on Size Specific Dose Estimation (SSDE) in CT: A Phantom Study

    NASA Astrophysics Data System (ADS)

    Alsanea, Maram M.

    Over the past number of years there has been a significant increase in the awareness of radiation dose from use of computed tomography (CT). Efforts have been made to reduce radiation dose from CT and to better quantify dose being delivered. However, unfortunately, these dose metrics such as CTDI vol are not a specific patient dose. In 2011, the size-specific dose estimation (SSDE) was introduced by AAPM TG-204 which accounts for the physical size of the patient. However, the approach presented in TG-204 ignores the importance of the attenuation differences in the body. In 2014, a newer methodology that accounted for tissue attenuation was introduced by the AAPM TG-220 based on the concept of water equivalent diameter, Dw. One of the limitation of TG-220 is that there is no estimation of the dose while highly attenuating objects such as metal is present in the body. The purpose of this research is to evaluate the accuracy of size-specific dose estimates in CT in the presence of simulated metal prostheses using a conventional PMMA CTDI phantom at different phantom diameter (body and head) and beam energy. Titanium, Cobalt- chromium and stainless steel alloys rods were used in the study. Two approaches were used as introduced by AAPM TG-204 and 220 utilizing the effective diameter and the Dw calculations. From these calculations, conversion factors have been derived that could be applied to the measured CTDIvol to convert it to specific patient dose, or size specific dose estimate, (SSDE). Radiation dose in tissue (f-factor = 0.94) was measured at various chamber positions with the presence of metal. Following, an average weighted tissue dose (AWTD) was calculated in a manner similar to the weighted CTDI (CTDIw). In general, for the 32 cm body phantom SSDE220 provided more accurate estimates of AWTD than did SSDE204. For smaller patient size, represented by the 16 cm head phantom, the SSDE204 was a more accurate estimate of AWTD that that of SSDE220. However, as the

  8. Comparison of measured and estimated maximum skin doses during CT fluoroscopy lung biopsies

    SciTech Connect

    Zanca, F.; Jacobs, A.; Crijns, W.; De Wever, W.

    2014-07-15

    Purpose: To measure patient-specific maximum skin dose (MSD) associated with CT fluoroscopy (CTF) lung biopsies and to compare measured MSD with the MSD estimated from phantom measurements, as well as with the CTDIvol of patient examinations. Methods: Data from 50 patients with lung lesions who underwent a CT fluoroscopy-guided biopsy were collected. The CT protocol consisted of a low-kilovoltage (80 kV) protocol used in combination with an algorithm for dose reduction to the radiology staff during the interventional procedure, HandCare (HC). MSD was assessed during each intervention using EBT2 gafchromic films positioned on patient skin. Lesion size, position, total fluoroscopy time, and patient-effective diameter were registered for each patient. Dose rates were also estimated at the surface of a normal-size anthropomorphic thorax phantom using a 10 cm pencil ionization chamber placed at every 30°, for a full rotation, with and without HC. Measured MSD was compared with MSD values estimated from the phantom measurements and with the cumulative CTDIvol of the procedure. Results: The median measured MSD was 141 mGy (range 38–410 mGy) while the median cumulative CTDIvol was 72 mGy (range 24–262 mGy). The ratio between the MSD estimated from phantom measurements and the measured MSD was 0.87 (range 0.12–4.1) on average. In 72% of cases the estimated MSD underestimated the measured MSD, while in 28% of the cases it overestimated it. The same trend was observed for the ratio of cumulative CTDIvol and measured MSD. No trend was observed as a function of patient size. Conclusions: On average, estimated MSD from dose rate measurements on phantom as well as from CTDIvol of patient examinations underestimates the measured value of MSD. This can be attributed to deviations of the patient's body habitus from the standard phantom size and to patient positioning in the gantry during the procedure.

  9. Dosimetric Evaluation of Metal Artefact Reduction using Metal Artefact Reduction (MAR) Algorithm and Dual-energy Computed Tomography (CT) Method

    NASA Astrophysics Data System (ADS)

    Laguda, Edcer Jerecho

    Purpose: Computed Tomography (CT) is one of the standard diagnostic imaging modalities for the evaluation of a patient's medical condition. In comparison to other imaging modalities such as Magnetic Resonance Imaging (MRI), CT is a fast acquisition imaging device with higher spatial resolution and higher contrast-to-noise ratio (CNR) for bony structures. CT images are presented through a gray scale of independent values in Hounsfield units (HU). High HU-valued materials represent higher density. High density materials, such as metal, tend to erroneously increase the HU values around it due to reconstruction software limitations. This problem of increased HU values due to metal presence is referred to as metal artefacts. Hip prostheses, dental fillings, aneurysm clips, and spinal clips are a few examples of metal objects that are of clinical relevance. These implants create artefacts such as beam hardening and photon starvation that distort CT images and degrade image quality. This is of great significance because the distortions may cause improper evaluation of images and inaccurate dose calculation in the treatment planning system. Different algorithms are being developed to reduce these artefacts for better image quality for both diagnostic and therapeutic purposes. However, very limited information is available about the effect of artefact correction on dose calculation accuracy. This research study evaluates the dosimetric effect of metal artefact reduction algorithms on severe artefacts on CT images. This study uses Gemstone Spectral Imaging (GSI)-based MAR algorithm, projection-based Metal Artefact Reduction (MAR) algorithm, and the Dual-Energy method. Materials and Methods: The Gemstone Spectral Imaging (GSI)-based and SMART Metal Artefact Reduction (MAR) algorithms are metal artefact reduction protocols embedded in two different CT scanner models by General Electric (GE), and the Dual-Energy Imaging Method was developed at Duke University. All three

  10. Prospective comparison of dual-energy CT aortography using 70% reduced iodine dose versus single-energy CT aortography using standard iodine dose in the same patient.

    PubMed

    Shuman, William P; O'Malley, Ryan B; Busey, Janet M; Ramos, Mario M; Koprowicz, Kent M

    2017-03-01

    To compare dual-energy computed tomography (DECT) aortography using a 70% reduced iodine dose to single-energy CT (SECT) aortography using a standard iodine dose in the same patient. Twenty-one patients with a prior SECT aortography using standard iodine dose had DECT aortography using 70% reduced iodine dose. Section 120 kVp images were compared to DECT images reconstructed at both 50 and 77 keV. Reviewers measured image noise and attenuation in the aorta at eight locations from proximal to distal and subjectively scored vascular enhancement on a four-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The volume CT dose index (CTDIvol) for each exam was recorded. Mean iodine dose was 50 g for SECT and 15 g for DECT (70% reduction). Mean aortic attenuation was similar for section 120 kVp (350 ± 67 HU) and DECT 50 keV (338 ± 57 HU, p = 0.547) but was lower at 77 keV (152 ± 23 HU). Measured image noise was greatest at 50 keV (12 ± 5 HU) and was lowest at 77 keV (7 ± 2 HU, p > 0.001). There was no difference in SNR or CNR between 120 kVp and 50 keV (p > 0.05). Mean subjective vascular enhancement scores for SECT were between good and excellent (3.33-3.69), and for DECT at 50 keV were between moderate and good (2.54-2.93, p < 0.0001). CTDIvol was 13.6 mGy for SECT and 13.1 mGy for DECT (p = 0.637). 70% Reduced iodine DECT aortography may result in similar aortic attenuation, CNR, SNR, and lower although acceptable subjective image scores when compared to standard iodine SECT aortography in the same patient.

  11. Evaluation of radiation dose delivered by cone beam CT and tomosynthesis employed for setup of external breast irradiation

    SciTech Connect

    Winey, Brian; Zygmanski, Piotr; Lyatskaya, Yulia

    2009-01-15

    A systematic set of measurements is reported for evaluation of doses to critical organs resulting from cone-beam CT (CB-CT) and cone-beam tomosynthesis (CB-TS) as applied to breast setup for external beam irradiation. The specific focus of this study was on evaluation of doses from these modalities in a setting of volumetric breast imaging for target localization in radiotherapy treatments with the goal of minimizing radiation to healthy organs. Ion chamber measurements were performed in an anthropomorphic female thorax phantom at the center of each breast and lung and on the phantom surface at one anterior and two lateral locations (seven points total). The measurements were performed for three different isocenters located at the center of the phantom and at offset locations of the right and left breast. The dependence of the dose on angle selection for the CB-TS arc was also studied. For the most typical situation of centrally located CB-CT isocenter the measured doses ranged between 3 and 7 cGy, in good agreement with previous reports. Dose measurements were performed for a range of start/stop angles commonly used for CB-TS and the impact of direct and scatter dose on organs at risk was analyzed. All measured CB-TS doses were considerably lower than CB-CT doses, with greater decrease in dose for the organs outside of the beam (up to 98% decrease in dose). Remarkably, offsetting the isocenter towards the ipsilateral breast resulted on average to additional 46% dose reduction to organs at risk. The lowest doses to the contralateral breast and lung were less than 0.1 cGy when they were measured for the offset isocenter. The biggest reduction in dose was obtained by using CB-TS beams that completely avoid the critical organ. For points inside the CB-TS beam, the dose was reduced in a linear relation with distance from the center of the imaging arc. The data indicate that it is possible to reduce substantially radiation doses to the contralateral organs by proper

  12. Characterization of a lead breast shielding for dose reduction in computed tomography*

    PubMed Central

    Correia, Paula Duarte; Granzotti, Cristiano Roberto Fabri; Santos, Yago da Silva; Brochi, Marco Aurelio Corte; de Azevedo-Marques, Paulo Mazzoncini

    2014-01-01

    Objective Several studies have been published regarding the use of bismuth shielding to protect the breast in computed tomography (CT) scans and, up to the writing of this article, only one publication about barium shielding was found. The present study was aimed at characterizing, for the first time, a lead breast shielding. Materials and Methods The percentage dose reduction and the influence of the shielding on quantitative imaging parameters were evaluated. Dose measurements were made on a CT equipment with the aid of specific phantoms and radiation detectors. A processing software assisted in the qualitative analysis evaluating variations in average CT number and noise on images. Results The authors observed a reduction in entrance dose by 30% and in CTDIvol by 17%. In all measurements, in agreement with studies in the literature, the utilization of cotton fiber as spacer object reduced significantly the presence of artifacts on the images. All the measurements demonstrated increase in the average CT number and noise on the images with the presence of the shielding. Conclusion As expected, the data observed with the use of lead shielding were of the same order as those found in the literature about bismuth shielding. PMID:25741089

  13. Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

    PubMed Central

    Li, Hua; Noel, Camille; Chen, Haijian; Harold Li, H.; Low, Daniel; Moore, Kevin; Klahr, Paul; Michalski, Jeff; Gay, Hiram A.; Thorstad, Wade; Mutic, Sasa

    2012-01-01

    Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The γ pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose

  14. Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

    SciTech Connect

    Li Hua; Noel, Camille; Chen, Haijian; Harold Li, H.; Low, Daniel; Moore, Kevin; Klahr, Paul; Michalski, Jeff; Gay, Hiram A.; Thorstad, Wade; Mutic, Sasa

    2012-12-15

    Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose

  15. Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing

    NASA Astrophysics Data System (ADS)

    Chen, Yang; Yin, Xindao; Shi, Luyao; Shu, Huazhong; Luo, Limin; Coatrieux, Jean-Louis; Toumoulin, Christine

    2013-08-01

    In abdomen computed tomography (CT), repeated radiation exposures are often inevitable for cancer patients who receive surgery or radiotherapy guided by CT images. Low-dose scans should thus be considered in order to avoid the harm of accumulative x-ray radiation. This work is aimed at improving abdomen tumor CT images from low-dose scans by using a fast dictionary learning (DL) based processing. Stemming from sparse representation theory, the proposed patch-based DL approach allows effective suppression of both mottled noise and streak artifacts. The experiments carried out on clinical data show that the proposed method brings encouraging improvements in abdomen low-dose CT images with tumors.

  16. Usefulness of Ultralow-Dose (Submillisievert) Chest CT Using Iterative Reconstruction for Initial Evaluation of Sharp Fish Bone Esophageal Foreign Body.

    PubMed

    Kim, Eun Young; Min, Young Gi; Bista, Anjali Basnyat; Park, Kyung Joo; Kang, Doo Kyoung; Sun, Joo Sung

    2015-11-01

    The purpose of this article was to evaluate the usefulness of ultralow-dose chest CT as an initial imaging study for evaluation of sharp fish bone esophageal foreign body (FB). A total of 57 subjects who underwent ultralow-dose chest CT were included in this retrospective study. All subjects had a history of ingestion and symptoms of esophageal FB. All ultralow-dose chest CT data were reconstructed twice, once with filtered back projection (FBP) and once with iterative reconstruction, and three observers reviewed the images independently. ROC analysis was used to evaluate diagnostic performance of ultralow-dose chest CT. Intraclass correlation coefficient (ICC) was calculated for analysis of interobserver agreement. Among 57 patients, 42 were confirmed as having esophageal FB. Significant objective noise reduction of mediastinum was achieved using an iterative reconstruction technique. Subjective image noise of iterative reconstruction was significantly better than that of FBP. Overall diagnostic performance of ultralow-dose chest CT for esophageal FB of iterative reconstruction (AUC = 0.999) was significantly better than that of FBP (AUC = 0.95) (p = 0.02). Interobserver agreement was greater for iterative reconstruction (ICC = 0.944) than for FBP (ICC = 0.778). Ultralow-dose chest CT using iterative reconstruction provided satisfactory diagnostic image quality for identifying fish bone esophageal FB with reduced radiation dose and high observer accuracy. Therefore, ultralow-dose chest CT would be adequate as a first-line imaging modality for fish bone esophageal FB.

  17. CT-guided multi-catheter insertion technique for partial breast brachytherapy: reliable target coverage and dose homogeneity.

    PubMed

    Cuttino, Laurie W; Todor, Dorin; Arthur, Douglas W

    2005-01-01

    coverage (defined as the percentage of PTV 2 cm receiving 90% of the prescribed dose) increased from 89% to 95% (p=0.007) and the mean DHI increased from 0.77 to 0.82 with the new technique (p < 0.005). Reproducible target coverage and dose homogeneity were achieved with CT-guided catheter insertion and 3D planning software. Catheters can be optimally placed with intraoperative CT evaluation and 3D planning software allows improved implant visualization resulting in optimized dosimetry. Improvements in target coverage and DHI may translate into optimized local control and improved cosmesis with a corresponding reduction in the risk of complications.

  18. [Multislice CT in a diagnostic imaging department: radiation doses delivered in 1 year.].

    PubMed

    Salmerón, Isabel; Calzado, Alfonso; Ruiz-López, Laura; Alonso, Verónica; Cordeiro, César; Fraile, Eduardo

    2009-01-01

    To determine the usage of CT in our diagnostic imaging department and the dose of radiation CT delivered to patients. We carried out two studies, a retrospective study on the administrative data from one year and a prospective study over one month, to determine the amount of activity of the two multislice CT scanners in our department. We recorded the total number of examinations, the different types of examination performed, and the age distributions of the patients examined. We used these data and the results of dosimetric measurements to estimate the typical radiation dose for each type of examination, its contribution to the collective radiation dose, and the total collective radiation dose from CT examinations at our hospital. The retrospective study found that 15038 examinations were performed in 12678 patients in one year. The most common CT examinations were cranial (38.2%), abdomen-pelvis (17.5%), chest-abdomen (11.7%), chest (9.3%), and lumbar-sacral spine (6.8%). Some protocols used doses of radiation that were higher than those recommended by European experts. The total collective dose of radiation delivered to patients at our hospital by CT was estimated at 70 person.Sv. Abdomen-pelvis examinations contributed 31% of the total dose. This study has provided detailed knowledge about the use of CT in our diagnostic imaging department, about the dose of radiation delivered, and about possibilities for improving the use of our CT scanners.

  19. Computerized lung nodule detection: comparison of performance for low-dose and standard-dose helical CT scans

    NASA Astrophysics Data System (ADS)

    Armato, Samuel G., III; Giger, Maryellen L.; Doi, Kunio; Bick, Ulrich; MacMahon, Heber

    2001-07-01

    The vast amount of image data acquired during a computed tomography (CT) scan makes lung nodule detection a burdensome task. Moreover, the growing acceptance of low-dose CT for lung cancer screening promises to further impact radiologists' workloads. Therefore, we have developed a computerized method to automatically analyze structures within a CT scan and identify those structures that represent lung nodules. Gray-level thresholding is performed to segment the lungs in each section to produce a segmented lung volume, which is then iteratively thresholded. At each iteration, remaining voxels are grouped into contiguous three-dimensional structures. Structures that satisfy a volume criterion then become nodule candidates. The set of nodule candidates is subjected to feature analysis. To distinguish candidates representing nodule and non-nodule structures, a rule-based approach is combined with an automated classifier. This method was applied to 43 standard-dose (diagnostic) CT scans and 13 low-dose CT scans. The method achieved an overall detection sensitivity of 71% with 1.5 false-positive detections per section on the standard-dose database and 71% sensitivity with 1.2 false-positive detections per section on the low-dose database. This automated method demonstrates promising performance in its ability to accurately detect lung nodules in standard-dose and low-dose CT images.

  20. Ultralow-radiation-dose chest CT: accuracy for lung densitometry and emphysema detection.

    PubMed

    Wang, Rui; Sui, Xin; Schoepf, U Joseph; Song, Wei; Xue, Huadan; Jin, Zhengyu; Schmidt, Bernhard; Flohr, Thomas G; Canstein, Christian; Spearman, James V; Chen, Jiuhong; Meinel, Felix G

    2015-04-01

    The purpose of this study was to determine whether ultralow-radiation-dose chest CT can be used for quantification of lung density and for emphysema detection in participants undergoing lung cancer screening. Fifty-two patients were prospectively enrolled and underwent scanning twice with low-dose CT (reference parameters, 120 kV, 50 effective mAs) and ultralow-dose CT (reference parameters, 80 kV, 4-5 effective mAs). Images were reconstructed by filtered back projection (FBP) for low-dose CT and FBP and iterative reconstruction (IR) for ultralow-dose CT. Radiation dose was recorded. Image noise, mean lung attenuation, 15th percentile of lung attenuation, and emphysema index were measured in each image series and compared. Test characteristics of ultralow-dose CT in detecting more than subtle emphysema (emphysema index≥3%) were calculated. The effective dose of low-dose CT was 2.1±0.5 mSv, and that of ultralow-dose CT was 0.13±0.04 mSv. Compared with the findings for low-dose CT, absolute overestimation of emphysema index was 7% on ultralow-dose CT images reconstructed with FBP and 2% on those processed with IR. The 15th percentile of lung attenuation was underestimated by 21.3 HU on ultralow-dose FBP images and by 5.8 HU on IR images. No relevant bias was observed for mean lung attenuation. Four patients (8%) had more than subtle emphysema. The emphysema index measured at ultralow-dose CT with FBP and IR had 100% and 100% sensitivity and 92% and 96% specificity in identifying patients with more than subtle emphysema at a cutoff of greater than 12.1% for FBP and greater than 6.7% for IR. Ultralow-dose chest CT performed for lung cancer screening can be used for quantification of lung density and for emphysema detection. IR improves the accuracy of ultralow-dose CT in this setting.

  1. Improving Low-dose Cardiac CT Images based on 3D Sparse Representation

    PubMed Central

    Shi, Luyao; Hu, Yining; Chen, Yang; Yin, Xindao; Shu, Huazhong; Luo, Limin; Coatrieux, Jean-Louis

    2016-01-01

    Cardiac computed tomography (CCT) is a reliable and accurate tool for diagnosis of coronary artery diseases and is also frequently used in surgery guidance. Low-dose scans should be considered in order to alleviate the harm to patients caused by X-ray radiation. However, low dose CT (LDCT) images tend to be degraded by quantum noise and streak artifacts. In order to improve the cardiac LDCT image quality, a 3D sparse representation-based processing (3D SR) is proposed by exploiting the sparsity and regularity of 3D anatomical features in CCT. The proposed method was evaluated by a clinical study of 14 patients. The performance of the proposed method was compared to the 2D spares representation-based processing (2D SR) and the state-of-the-art noise reduction algorithm BM4D. The visual assessment, quantitative assessment and qualitative assessment results show that the proposed approach can lead to effective noise/artifact suppression and detail preservation. Compared to the other two tested methods, 3D SR method can obtain results with image quality most close to the reference standard dose CT (SDCT) images. PMID:26980176

  2. Low-dose multiphase abdominal CT reconstruction with phase-induced swap prior

    NASA Astrophysics Data System (ADS)

    Selim, Mona; Rashed, Essam A.; Kudo, Hiroyuki

    2016-10-01

    Multiphase abdominal CT is an imaging protocol in which the patient is scanned at different phases before and after the injection of a contrast agent. Reconstructed images with different concentrations of contrast material provide useful information for effective detection of abnormalities. However, several scanning during a short period of time eventually increase the patient radiation dose to a remarkable value up to a risky level. Reducing the patient dose by modulating the x-ray tube c