Sample records for ct hot section

  1. A theoretical study on hot charge-transfer states and dimensional effects of organic photocells based on an ideal diode model.

    PubMed

    Shimazaki, Tomomi; Nakajima, Takahito

    2017-05-21

    This paper discusses an ideal diode model with hot charge-transfer (CT) states to analyze the power conversion efficiency of an organic photocell. A free carrier generation mechanism via sunlight in an organic photocell consists of four microscopic processes: photon absorption, exciton dissociation, CT, and charge separation. The hot CT state effect has been actively investigated to understand the charge separation process. We previously reported a theoretical method to calculate the efficiency of the charge separation process via a hot CT state (T. Shimazaki et al., Phys. Chem. Chem. Phys., 2015, 17, 12538 and J. Chem. Phys., 2016, 144, 234906). In this paper, we integrate the simulation method into the ideal photocell diode model and calculate several properties such as short circuit current, open circuit voltage, and power conversion efficiency. Our results highlight that utilizing the dimensional (entropy) effect together with the hot CT state can play an essential role in developing more efficient organic photocell devices.

  2. Effect of Sm-Rich Phase on Corrosion Behavior of Hot-Extruded AZ31-1.5Sm Magnesium Alloy

    NASA Astrophysics Data System (ADS)

    Li, Xiao; Hu, Zhi; Yan, Hong; Wu, Xiaoquan; Xie, Hecong; Dong, Zhou

    2018-05-01

    The effects of Sm on the corrosion and microstructure behavior of hot-extruded AZ31 magnesium alloy were investigated by SEM, TEM, weight loss analysis, and electrochemical measurements. The results indicated that granular Al2Sm phase 4 μm in size in the hot-extruded AZ31 magnesium alloy modified with 1.5 wt.% Sm leads to significant grain refinement. The corrosion rate decreased from 15.98 × 10-4 to 11.19 × 10-4 g cm-2 h-1 in the transverse section and from 8.57 × 10-4 to 6.20 × 10-4 g cm-2 h-1 in the longitudinal section. Compared to the unmodified alloy, the corrosion potential of the Sm-modified alloy in the transverse and longitudinal sections increased by 98 and 62 mV, respectively, and the R ct value (charge transfer resistance) in the transverse and longitudinal sections of the modified alloy increased from 1764 and 1756 to 2928 and 2408 Ω cm2, respectively. The results showed that the corrosion resistance of hot-extruded AZ31 magnesium alloy was significantly improved by Sm addition due to the grain refinement, the decreased dislocation density, and the suppression of micro-galvanic corrosion caused by Al-Sm-(Mn) intermetallic compounds.

  3. Low-activity 124I-PET/low-dose CT versus 99mTc-pertechnetate planar scintigraphy or 99mTc-pertechnetate single-photon emission computed tomography of the thyroid: a pilot comparison.

    PubMed

    Darr, Andreas M; Opfermann, Thomas; Niksch, Tobias; Driesch, Dominik; Marlowe, Robert J; Freesmeyer, Martin

    2013-10-01

    The standard thyroid functional imaging method, 99mTc-pertechnetate (99mTc-PT) planar scintigraphy, has technical drawbacks decreasing its sensitivity in detecting nodules or anatomical pathology. 124I-PET, lacking these disadvantages and allowing simultaneous CT, may have greater sensitivity for these purposes. We performed a blinded pilot comparison of 124I-PET(/CT) versus 99mTc-PT planar scintigraphy or its cross-sectional enhancement, 99mTc-PT single-photon emission CT (SPECT), in characterizing the thyroid gland with benign disease. Twenty-one consecutive adults with goiter underwent low-activity (1 MBq/0.027 mCi) 124I-PET/low-dose (30 mAs) CT, 99mTc-PT planar scintigraphy, and 99mTc-PT-SPECT. Endpoints included the numbers of “hot spots” with/without central photopenia and “cold spots” detected, the proportion of these lesions with morphological correlates, the mean volume and diameter of visualized nodules, and the number of cases of lobus pyramidalis or retrosternal thyroid tissue identified. 124I-PET detected significantly more “hot spots” with/without central photopenia (P < 0.001), significantly more nodules (P < 0.001), and more “cold spots” than did 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT, including all lesions seen on the 99mTc-PT modalities. Ultrasonographic correlates were found for all nodules visualized on all 3 modalities and 92.5% of nodules seen only on 124I-PET. Nodules discernible only on 124I-PET had significantly smaller mean volume or diameter (P < 0.001) than did those visualized on 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT. 124I-PET(/CT) identified significantly more patients with a lobus pyramidalis (P < 0.001) or retrosternal thyroid tissue (P < 0.05). 124I-PET(/CT) may provide superior imaging of benign thyroid disease compared to planar or cross-sectional 99mTc-PT scintigraphy.

  4. Lung Hot Spot Without Corresponding Computed Tomography Abnormality on Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Artifactual or Real, Iatrogenic or Pathologic?

    PubMed

    Liu, Yiyan

    Focal lung uptake without corresponding lesions or abnormalities on computed tomography (CT) scan poses a dilemma in the interpretation of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). A limited number of case reports have previously suggested an artifactual or iatrogenic nature of the uptake. In the present study, 8 relevant cases were included within a retrospective search of the database. Medical records were reviewed for follow-up radiological and pathologic information. In 7 of 8 cases with focal increased FDG uptake but no corresponding lesions or abnormalities on CT scan, the lung hot spots were artifactual or iatrogenic upon follow-up diagnostic chest CT or repeated PET/CT or both the scans. Microemboli were most likely a potential cause of the pulmonary uptake, with or without partial paravenous injection. One case in the series had a real pulmonary lesion demonstrated on follow-up PET/CT scans and on surgical pathology, although the initial integrated CT and follow-up diagnostic chest CT scans revealed negative findings to demonstrate pulmonary abnormalities corresponding to the hot spot on the PET scan. In conclusion, the finding of a lung hot spot in the absence of anatomical abnormality on FDG PET/CT was most likely artifactual or iatrogenic, but it might also represent a real pulmonary lesion. Nonvisualization of anatomical abnormality could be because of its small size and position directly overlying a segmental vessel. Further image follow-up is necessary and important to clarify the nature of the uptake. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. CT-guided automated detection of lung tumors on PET images

    NASA Astrophysics Data System (ADS)

    Cui, Yunfeng; Zhao, Binsheng; Akhurst, Timothy J.; Yan, Jiayong; Schwartz, Lawrence H.

    2008-03-01

    The calculation of standardized uptake values (SUVs) in tumors on serial [ 18F]2-fluoro-2-deoxy-D-glucose ( 18F-FDG) positron emission tomography (PET) images is often used for the assessment of therapy response. We present a computerized method that automatically detects lung tumors on 18F-FDG PET/Computed Tomography (CT) images using both anatomic and metabolic information. First, on CT images, relevant organs, including lung, bone, liver and spleen, are automatically identified and segmented based on their locations and intensity distributions. Hot spots (SUV >= 1.5) on 18F-FDG PET images are then labeled using the connected component analysis. The resultant "hot objects" (geometrically connected hot spots in three dimensions) that fall into, reside at the edges or are in the vicinity of the lungs are considered as tumor candidates. To determine true lesions, further analyses are conducted, including reduction of tumor candidates by the masking out of hot objects within CT-determined normal organs, and analysis of candidate tumors' locations, intensity distributions and shapes on both CT and PET. The method was applied to 18F-FDG-PET/CT scans from 9 patients, on which 31 target lesions had been identified by a nuclear medicine radiologist during a Phase II lung cancer clinical trial. Out of 31 target lesions, 30 (97%) were detected by the computer method. However, sensitivity and specificity were not estimated because not all lesions had been marked up in the clinical trial. The method effectively excluded the hot spots caused by mediastinum, liver, spleen, skeletal muscle and bone metastasis.

  6. Charge-transfer excitons at organic semiconductor surfaces and interfaces.

    PubMed

    Zhu, X-Y; Yang, Q; Muntwiler, M

    2009-11-17

    When a material of low dielectric constant is excited electronically from the absorption of a photon, the Coulomb attraction between the excited electron and the hole gives rise to an atomic H-like quasi-particle called an exciton. The bound electron-hole pair also forms across a material interface, such as the donor/acceptor interface in an organic heterojunction solar cell; the result is a charge-transfer (CT) exciton. On the basis of typical dielectric constants of organic semiconductors and the sizes of conjugated molecules, one can estimate that the binding energy of a CT exciton across a donor/acceptor interface is 1 order of magnitude greater than k(B)T at room temperature (k(B) is the Boltzmann constant and T is the temperature). How can the electron-hole pair escape this Coulomb trap in a successful photovoltaic device? To answer this question, we use a crystalline pentacene thin film as a model system and the ubiquitous image band on the surface as the electron acceptor. We observe, in time-resolved two-photon photoemission, a series of CT excitons with binding energies < or = 0.5 eV below the image band minimum. These CT excitons are essential solutions to the atomic H-like Schrodinger equation with cylindrical symmetry. They are characterized by principal and angular momentum quantum numbers. The binding energy of the lowest lying CT exciton with 1s character is more than 1 order of magnitude higher than k(B)T at room temperature. The CT(1s) exciton is essentially the so-called exciplex and has a very low probability of dissociation. We conclude that hot CT exciton states must be involved in charge separation in organic heterojunction solar cells because (1) in comparison to CT(1s), hot CT excitons are more weakly bound by the Coulomb potential and more easily dissociated, (2) density-of-states of these hot excitons increase with energy in the Coulomb potential, and (3) electronic coupling from a donor exciton to a hot CT exciton across the D/A interface can be higher than that to CT(1s) as expected from energy resonance arguments. We suggest a design principle in organic heterojunction solar cells: there must be strong electronic coupling between molecular excitons in the donor and hot CT excitons across the D/A interface.

  7. Theoretical study on the cooperative exciton dissociation process based on dimensional and hot charge-transfer state effects in an organic photocell

    NASA Astrophysics Data System (ADS)

    Shimazaki, Tomomi; Nakajima, Takahito

    2016-06-01

    This paper discusses the exciton dissociation process at the donor-acceptor interface in organic photocells. In our previous study, we introduced a local temperature to handle the hot charge-transfer (CT) state and calculated the exciton dissociation probability based on the 1D organic semiconductor model [T. Shimazaki and T. Nakajima, Phys. Chem. Chem. Phys. 17, 12538 (2015)]. Although the hot CT state plays an essential role in exciton dissociations, the probabilities calculated are not high enough to efficiently separate bound electron-hole pairs. This paper focuses on the dimensional (entropy) effect together with the hot CT state effect and shows that cooperative behavior between both effects can improve the exciton dissociation process. In addition, we discuss cooperative effects with site-disorders and external-electric-fields.

  8. Theoretical study on the cooperative exciton dissociation process based on dimensional and hot charge-transfer state effects in an organic photocell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shimazaki, Tomomi; Nakajima, Takahito

    2016-06-21

    This paper discusses the exciton dissociation process at the donor–acceptor interface in organic photocells. In our previous study, we introduced a local temperature to handle the hot charge-transfer (CT) state and calculated the exciton dissociation probability based on the 1D organic semiconductor model [T. Shimazaki and T. Nakajima, Phys. Chem. Chem. Phys. 17, 12538 (2015)]. Although the hot CT state plays an essential role in exciton dissociations, the probabilities calculated are not high enough to efficiently separate bound electron–hole pairs. This paper focuses on the dimensional (entropy) effect together with the hot CT state effect and shows that cooperative behaviormore » between both effects can improve the exciton dissociation process. In addition, we discuss cooperative effects with site-disorders and external-electric-fields.« less

  9. Hot kinetic model as a guide to improve organic photovoltaic materials.

    PubMed

    Sosorev, Andrey Yu; Godovsky, Dmitry Yu; Paraschuk, Dmitry Yu

    2018-01-31

    The modeling of organic solar cells (OSCs) can provide a roadmap for their further improvement. Many OSC models have been proposed in recent years; however, the impact of the key intermediates from photons to electricity-hot charge-transfer (CT) states-on the OSC efficiency is highly ambiguous. In this study, we suggest an analytical kinetic model for OSC that considers a two-step charge generation via hot CT states. This hot kinetic model allowed us to evaluate the impact of different material parameters on the OSC performance: the driving force for charge separation, optical bandgap, charge mobility, geminate recombination rate, thermalization rate, average electron-hole separation distance in the CT state, dielectric permittivity, reorganization energy and charge delocalization. In contrast to a widespread trend of lowering the material bandgap, the model predicts that this approach is only efficient along with improvement of the other material properties. The most promising ways to increase the OSC performance are decreasing the reorganization energy, i.e., an energy change accompanying CT from the donor molecule to the acceptor, increasing the dielectric permittivity and charge delocalization. The model suggests that there are no fundamental limitations that can prevent achieving the OSC efficiency above 20%.

  10. [Relationship between image quality and cross-sectional area of phantom in three-dimensional positron emission tomography scan].

    PubMed

    Osawa, Atsushi; Miwa, Kenta; Wagatsuma, Kei; Takiguchi, Tomohiro; Tamura, Shintaro; Akimoto, Kenta

    2012-01-01

    The image quality in (18)FDG PET/CT often degrades as the body size increases. The purpose of this study was to evaluate the relationship between image quality and the body size using original phantoms of variable cross-sectional areas in PET/CT. We produced five water phantoms with different cross-sectional areas. The long axis of phantom was 925 mm, and the cross-sectional area was from 324 to 1189 cm(2). These phantoms with the sphere (diameter 10 mm) were filled with (18)F-FDG solution. The radioactivity concentration of background in the phantom was 1.37, 2.73, 4.09 and 5.46 kBq/mL. The scanning duration was 30 min in list mode acquisition for each measurement. Background variability (N(10 mm)), noise equivalent count rates (NECR(phantom)), hot sphere contrast (Q(H,10 mm)) as physical evaluation and visual score of sphere detection were measured, respectively. The relationship between image quality and the various cross-sectional areas was also analyzed under the above-mentioned conditions. As cross-sectional area increased, NECR(phantom) progressively decreased. Furthermore, as cross-sectional area increased, N(10 mm) increased and Q(H,10 mm) decreased. Image quality became degraded as body weight increased because noise and contrast contributed to image quality. The visual score of sphere detection deteriorated in high background radioactivity concentration because a false positive detection in cross-sectional area of the phantom increased. However, additional increases in scanning periods could improve the visual score. We assessed tendencies in the relationship between image quality and body size in PET/CT. Our results showed that time adjustment was more effective than dose adjustment for stable image quality of heavier patients in terms of the large cross-sectional area.

  11. Coal-Tar-Sealcoated Parking Lots: "Hot spots" of PAHs and N-heterocycles to Urban Streams and Lakes Result in "Hot Moments" of Toxicity

    NASA Astrophysics Data System (ADS)

    Mahler, B. J.; Van Metre, P. C.; Ingersoll, C.; Kunz, J. L.

    2014-12-01

    Coal-tar (CT) sealcoat, a potent source of polycyclic aromatic hydrocarbons (PAHs) and N-heterocycles, is applied to asphalt pavement of parking lots and driveways in many parts of the U.S. and Canada every 1 to 5 years. We measured the chemistry and toxicity of unfiltered runoff resulting from rain events simulated from 5 hours to 111 days after application of CT or asphalt (AS) sealcoat. PAHs and N-heterocycles were measured by GC/EIMS. Toxicity tests were done with Ceriodaphnia dubia and Pimephales promelas exposed 48 hours to undiluted and diluted (1 part runoff 9 parts control water) runoff under ambient lighting. Organisms were then transferred to fresh control water and subjected to a 4-hour pulse of ultraviolet radiation (UVR). Concentrations of 2- and 3-ringed PAHs and N-heterocycles in CT runoff, initially high (sum of 6 PAHs, 220 μg/L; sum of 7 N-heterocycles, 904 μg/L), decreased rapidly, whereas concentrations of 4-, 5- and 6-ringed PAHs more than doubled by 7 days after application (sum of 9 PAHs, 378 μg/L) and remained elevated 111 days after application (sum of 9 PAHs, 283 μg/L). Concentrations of PAHs and N-heterocycles in AS sealcoated runoff followed a similar pattern, but were ~10 times lower than those in CT runoff; concentrations in a sample of runoff from unsealed asphalt pavement were near or less than the detection limit. Organisms exposed to samples of undiluted CT-runoff collected during the 36 days following CT sealcoat application (no UVR exposure) experienced 100% mortality. Mortality (as much as 100%) of organisms exposed to the 10% dilution of CT runoff or to undiluted AS runoff occurred only with UVR; mortality of organisms exposed to the 10% solution of AS runoff and UVR was minimal. Results demonstrate that freshly CT-sealed parking lots and driveways are "hot spots" of PAH and N-heterocycle contamination and that prolonged "hot moments" of toxicity follow CT sealcoat application.

  12. Sentinel nodes identified by computed tomography-lymphography accurately stage the axilla in patients with breast cancer

    PubMed Central

    2013-01-01

    Background Sentinel node biopsy often results in the identification and removal of multiple nodes as sentinel nodes, although most of these nodes could be non-sentinel nodes. This study investigated whether computed tomography-lymphography (CT-LG) can distinguish sentinel nodes from non-sentinel nodes and whether sentinel nodes identified by CT-LG can accurately stage the axilla in patients with breast cancer. Methods This study included 184 patients with breast cancer and clinically negative nodes. Contrast agent was injected interstitially. The location of sentinel nodes was marked on the skin surface using a CT laser light navigator system. Lymph nodes located just under the marks were first removed as sentinel nodes. Then, all dyed nodes or all hot nodes were removed. Results The mean number of sentinel nodes identified by CT-LG was significantly lower than that of dyed and/or hot nodes removed (1.1 vs 1.8, p <0.0001). Twenty-three (12.5%) patients had ≥2 sentinel nodes identified by CT-LG removed, whereas 94 (51.1%) of patients had ≥2 dyed and/or hot nodes removed (p <0.0001). Pathological evaluation demonstrated that 47 (25.5%) of 184 patients had metastasis to at least one node. All 47 patients demonstrated metastases to at least one of the sentinel nodes identified by CT-LG. Conclusions CT-LG can distinguish sentinel nodes from non-sentinel nodes, and sentinel nodes identified by CT-LG can accurately stage the axilla in patients with breast cancer. Successful identification of sentinel nodes using CT-LG may facilitate image-based diagnosis of metastasis, possibly leading to the omission of sentinel node biopsy. PMID:24321242

  13. 18F-FDG PET/CT Equivalent of the Hepatic Hot Spot Sign With CT Correlation.

    PubMed

    Jundt, Michael C; Broski, Stephen M; Binkovitz, Larry A

    2018-05-01

    A 43-year-old woman presented with an FDG-avid mediastinal Ewing sarcoma invading and nearly occluding the superior vena cava. Geographic increased FDG uptake in hepatic segment IVA was the only other site of nonphysiologic FDG activity. This focal activity was without an underlying mass, had atypical morphology for a hepatic metastasis, and correlated well with prior CT findings of abnormal segment IVA enhancement resulting from the recruitment of portocaval collaterals. In the correct setting, the F-FDG hepatic hot spot should be considered in the differential of a focal FDG-avid hepatic lesion in segment IVA.

  14. Use of quantitative SPECT/CT reconstruction in 99mTc-sestamibi imaging of patients with renal masses.

    PubMed

    Jones, Krystyna M; Solnes, Lilja B; Rowe, Steven P; Gorin, Michael A; Sheikhbahaei, Sara; Fung, George; Frey, Eric C; Allaf, Mohamad E; Du, Yong; Javadi, Mehrbod S

    2018-02-01

    Technetium-99m ( 99m Tc)-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) has previously been shown to allow for the accurate differentiation of benign renal oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) apart from other malignant renal tumor histologies, with oncocytomas/HOCTs showing high uptake and renal cell carcinoma (RCC) showing low uptake based on uptake ratios from non-quantitative single-photon emission computed tomography (SPECT) reconstructions. However, in this study, several tumors fell close to the uptake ratio cutoff, likely due to limitations in conventional SPECT/CT reconstruction methods. We hypothesized that application of quantitative SPECT/CT (QSPECT) reconstruction methods developed by our group would provide more robust separation of hot and cold lesions, serving as an imaging framework on which quantitative biomarkers can be validated for evaluation of renal masses with 99m Tc-sestamibi. Single-photon emission computed tomography data were reconstructed using the clinical Flash 3D reconstruction and QSPECT methods. Two blinded readers then characterized each tumor as hot or cold. Semi-quantitative uptake ratios were calculated by dividing lesion activity by background renal activity for both Flash 3D and QSPECT reconstructions. The difference between median (mean) hot and cold tumor uptake ratios measured 0.655 (0.73) with the QSPECT method and 0.624 (0.67) with the conventional method, resulting in increased separation between hot and cold tumors. Sub-analysis of 7 lesions near the separation point showed a higher absolute difference (0.16) between QPSECT and Flash 3D mean uptake ratios compared to the remaining lesions. Our finding of improved separation between uptake ratios of hot and cold lesions using QSPECT reconstruction lays the foundation for additional quantitative SPECT techniques such as SPECT-UV in the setting of renal 99m Tc-sestamibi and other SPECT/CT exams. With robust quantitative image reconstruction and biomarker analysis, there may be an expanded role for SPECT/CT imaging in renal masses and other pathologic conditions.

  15. 77 FR 70142 - Initialed Draft Revision to the Agreement Suspending the Antidumping Investigation on Certain Hot...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-23

    ...; API 5L Grades A & B....... Two--HSLA & HSLA-F Quality Grades: A572, A1011-HSLAS; A1018-HSLAS, A1011-HSLAS- $661.92 F; A1018-HSLAS-F; API 5L Gr. X42, X46, X52, X56, X60; API 5CT Grades J55 and K55 Three--High Grade Coils and Sheets for Pipes and Casings API 5L Gr. X65, X70, and X80 $770.24 Section III.E is...

  16. Evaluation of dynamic infrared thermography as an alternative to CT angiography for perforator mapping in breast reconstruction: a clinical study.

    PubMed

    Weum, Sven; Mercer, James B; de Weerd, Louis

    2016-07-15

    The current gold standard for preoperative perforator mapping in breast reconstruction with a DIEP flap is CT angiography (CTA). Dynamic infrared thermography (DIRT) is an imaging method that does not require ionizing radiation or contrast injection. We evaluated if DIRT could be an alternative to CTA in perforator mapping. Twenty-five patients scheduled for secondary breast reconstruction with a DIEP flap were included. Preoperatively, the lower abdomen was examined with hand-held Doppler, DIRT and CTA. Arterial Doppler sound locations were marked on the skin. DIRT examination involved rewarming of the abdominal skin after a mild cold challenge. The locations of hot spots on DIRT were compared with the arterial Doppler sound locations. The rate and pattern of rewarming of the hot spots were analyzed. Multiplanar CT reconstructions were used to see if hot spots were related to perforators on CTA. All flaps were based on the perforator selected with DIRT and the surgical outcome was analyzed. First appearing hot spots were always associated with arterial Doppler sounds and clearly visible perforators on CTA. The hot spots on DIRT images were always slightly laterally located in relation to the exit points of the associated perforators through the rectus abdominis fascia on CTA. Some periumbilical perforators were not associated with hot spots and showed communication with the superficial inferior epigastric vein on CTA. The selected perforators adequately perfused all flaps. This study confirms that perforators selected with DIRT have arterial Doppler sound, are clearly visible on CTA and provide adequate perfusion for DIEP breast reconstruction. Retrospectively registered at ClinicalTrials.gov with identifier NCT02806518 .

  17. A comparative study between evaluation methods for quality control procedures for determining the accuracy of PET/CT registration

    NASA Astrophysics Data System (ADS)

    Cha, Min Kyoung; Ko, Hyun Soo; Jung, Woo Young; Ryu, Jae Kwang; Choe, Bo-Young

    2015-08-01

    The Accuracy of registration between positron emission tomography (PET) and computed tomography (CT) images is one of the important factors for reliable diagnosis in PET/CT examinations. Although quality control (QC) for checking alignment of PET and CT images should be performed periodically, the procedures have not been fully established. The aim of this study is to determine optimal quality control (QC) procedures that can be performed at the user level to ensure the accuracy of PET/CT registration. Two phantoms were used to carry out this study: the American college of Radiology (ACR)-approved PET phantom and National Electrical Manufacturers Association (NEMA) International Electrotechnical Commission (IEC) body phantom, containing fillable spheres. All PET/CT images were acquired on a Biograph TruePoint 40 PET/CT scanner using routine protocols. To measure registration error, the spatial coordinates of the estimated centers of the target slice (spheres) was calculated independently for the PET and the CT images in two ways. We compared the images from the ACR-approved PET phantom to that from the NEMA IEC body phantom. Also, we measured the total time required from phantom preparation to image analysis. The first analysis method showed a total difference of 0.636 ± 0.11 mm for the largest hot sphere and 0.198 ± 0.09 mm for the largest cold sphere in the case of the ACR-approved PET phantom. In the NEMA IEC body phantom, the total difference was 3.720 ± 0.97 mm for the largest hot sphere and 4.800 ± 0.85 mm for the largest cold sphere. The second analysis method showed that the differences in the x location at the line profile of the lesion on PET and CT were (1.33, 1.33) mm for a bone lesion, (-1.26, -1.33) mm for an air lesion and (-1.67, -1.60) mm for a hot sphere lesion for the ACR-approved PET phantom. For the NEMA IEC body phantom, the differences in the x location at the line profile of the lesion on PET and CT were (-1.33, 4.00) mm for the air lesion and (1.33, -1.29) mm for a hot sphere lesion. These registration errors from this study were reasonable compared to the errors reported in previous studies. Meanwhile, the total time required from phantom preparation was 67.72 ± 4.50 min for the ACR-approved PET phantom and 96.78 ± 8.50 min for the NEMA IEC body phantom. When the registration errors and the lead times are considered, the method using the ACR-approved PET phantom was more practical and useful than the method using the NEMA IEC body phantom.

  18. Hotter nests produce hatchling lizards with lower thermal tolerance.

    PubMed

    Dayananda, Buddhi; Murray, Brad R; Webb, Jonathan K

    2017-06-15

    In many regions, the frequency and duration of summer heatwaves is predicted to increase in future. Hotter summers could result in higher temperatures inside lizard nests, potentially exposing embryos to thermally stressful conditions during development. Potentially, developmentally plastic shifts in thermal tolerance could allow lizards to adapt to climate warming. To determine how higher nest temperatures affect the thermal tolerance of hatchling geckos, we incubated eggs of the rock-dwelling velvet gecko, Amalosia lesueurii , at two fluctuating temperature regimes to mimic current nest temperatures (mean 23.2°C, range 10-33°C, 'cold') and future nest temperatures (mean 27.0°C, range 14-37°C, 'hot'). Hatchlings from the hot incubation group hatched 27 days earlier and had a lower critical thermal maximum (CT max 38.7°C) and a higher critical thermal minimum (CT min 6.2°C) than hatchlings from cold incubation group (40.2 and 5.7°C, respectively). In the field, hatchlings typically settle under rocks near communal nests. During the hatching period, rock temperatures ranged from 13 to 59°C, and regularly exceeded the CT max of both hot- and cold-incubated hatchlings. Because rock temperatures were so high, the heat tolerance of lizards had little effect on their ability to exploit rocks as retreat sites. Instead, the timing of hatching dictated whether lizards could exploit rocks as retreat sites; that is, cold-incubated lizards that hatched later encountered less thermally stressful environments than earlier hatching hot-incubated lizards. In conclusion, we found no evidence that CT max can shift upwards in response to higher incubation temperatures, suggesting that hotter summers may increase the vulnerability of lizards to climate warming. © 2017. Published by The Company of Biologists Ltd.

  19. Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial.

    PubMed

    Zhu, Yanjia; Geng, Caizheng; Huang, Jia; Liu, Juzhen; Wu, Ning; Xin, Jun; Xu, Hao; Yu, Lijuan; Geng, Jianhua

    2018-06-13

    To ensure the reliability of the planned multi-center clinical trial, we assessed the consistence and comparability of the quantitative parameters of the eight PET/CT units that will be used in this trial. PET/CT images were scanned using a PET NEMA image quality phantom (Biodex) on the eight units of Discovery PET/CT 690 from GE Healthcare. The scanning parameters were the same with the ones to be used in the planned trial. The 18 F-NaF concentration in the background was 5.3 kBq/ml, while the ones in the spheres of diameter 37 mm, 22 mm, 17 mm and 10 mm were 8:1 as to that of the background and the ones in the spheres of diameter 28 mm and 13 mm were 0 kBq/ml. The consistency of hot sphere recovery coefficient (HRC), cold sphere recovery coefficient (CRC), hot sphere contrast (Q H ) and cold sphere contrast (Q c ) among these 8 PET/CTs was analyzed. The variation of the main quantitative parameters of the eight PET/CT systems was within 10%, which is acceptable for the clinical trial.

  20. Draft genome sequence of Lampropedia cohaerens strain CT6(T) isolated from arsenic rich microbial mats of a Himalayan hot water spring.

    PubMed

    Tripathi, Charu; Mahato, Nitish K; Rani, Pooja; Singh, Yogendra; Kamra, Komal; Lal, Rup

    2016-01-01

    Lampropedia cohaerens strain CT6(T), a non-motile, aerobic and coccoid strain was isolated from arsenic rich microbial mats (temperature ~45 °C) of a hot water spring located atop the Himalayan ranges at Manikaran, India. The present study reports the first genome sequence of type strain CT6(T) of genus Lampropedia cohaerens. Sequencing data was generated using the Illumina HiSeq 2000 platform and assembled with ABySS v 1.3.5. The 3,158,922 bp genome was assembled into 41 contigs with a mean GC content of 63.5 % and 2823 coding sequences. Strain CT6(T) was found to harbour genes involved in both the Entner-Duodoroff pathway and non-phosphorylated ED pathway. Strain CT6(T) also contained genes responsible for imparting resistance to arsenic, copper, cobalt, zinc, cadmium and magnesium, providing survival advantages at a thermal location. Additionally, the presence of genes associated with biofilm formation, pyrroloquinoline-quinone production, isoquinoline degradation and mineral phosphate solubilisation in the genome demonstrate the diverse genetic potential for survival at stressed niches.

  1. Image-guided brachytherapy for cervical cancer: analysis of D2 cc hot spot in three-dimensional and anatomic factors affecting D2 cc hot spot in organs at risk.

    PubMed

    Kim, Robert Y; Dragovic, Alek F; Whitley, Alexander C; Shen, Sui

    2014-01-01

    To analyze the D2 cc hot spot in three-dimensional CT and anatomic factors affecting the D2 cc hot spot in organs at risk (OARs). Thirty-one patients underwent pelvic CT scan after insertion of the applicator. High-dose-rate treatment planning was performed with standard loading patterns. The D2 cc structures in OARs were generated in three dimensional if the total equivalent dose in 2 Gy exceeded our defined dose limits (hot spot). The location of D2 cc hot spot was defined as the center of the largest D2 cc fragment. The relationship between the hot spot and the applicator position was reported in Digital Imaging and Communication in Medicine coordinates. The location of sigmoid, small bowel, and bladder D2 cc hot spots was around the endocervix: The mean location of sigmoid hot spot for lateral view was 1.6 cm posteriorly and 2.3 cm superiorly (Y, 1.6 and Z, 2.3), small bowel was 1.6 cm anteriorly and 2.7 cm superiorly (Y, -1.6 and Z, 2.7). The mean location of bladder hot spot was 1.6 cm anteriorly and 1.6 cm superiorly (Y, -1.6 and Z, 1.6). These hot spots were near the plane of Point A (X, 2.0 or -2.0; Y, 0; and Z, 2.0). The mean location of rectal hot spot was 1.6 cm posteriorly and 1.9 cm inferiorly (Y, 1.6 and Z, -1.9). D2 cc hot spot was affected by uterine wall thickness, uterine tandem position, fibroids, bladder fullness, bowel gas, and vaginal packing. Because of the location of the D2 cc hot spots, larger tumors present a challenge for adequate tumor coverage with a conventional brachytherapy applicator without an interstitial implant. Additionally, anatomic factors were identified which affect the D2 cc hot spot in OARs. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  2. Toward improved durability in advanced aircraft engine hot sections

    NASA Technical Reports Server (NTRS)

    Sokolowski, Daniel E. (Editor)

    1989-01-01

    The conference on durability improvement methods for advanced aircraft gas turbine hot-section components discussed NASA's Hot Section Technology (HOST) project, advanced high-temperature instrumentation for hot-section research, the development and application of combustor aerothermal models, and the evaluation of a data base and numerical model for turbine heat transfer. Also discussed are structural analysis methods for gas turbine hot section components, fatigue life-prediction modeling for turbine hot section materials, and the service life modeling of thermal barrier coatings for aircraft gas turbine engines.

  3. 40 CFR 1066.820 - Composite calculations for FTP exhaust emissions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... composite gaseous test results as a mass-weighted value, e [emission]-FTPcomp, in grams per mile using the... UDDS test interval (generally known as bag 1 and bag 2), in grams. D ct = the measured driving distance... emissions determined from the hot-start UDDS test interval in grams. This is the hot-stabilized portion from...

  4. "Shin splint" syndrome and tibial stress fracture in the same patient diagnosed by means of (99m)Tc-HMDP SPECT/CT.

    PubMed

    Vicente, Justo Serrano; Grande, Maria Luz Domínguez; Torre, Jose Rafael Infante; Madrid, Juan Ignacio Rayo; Barquero, Carmen Durán; Bernardo, Lucía García; Sánchez, Román Sánchez

    2013-04-01

    We show a patient who presented leg pain triggered by intense exercise. The most likely diagnosis was a possible tibial stress fracture or a "shin splint" syndrome (soleus enthesopathy). We performed a bone scintigraphy including SPECT/CT that revealed the presence of the two concomitant pathologies. SPECT/CT identified the hot spot superimposed with bone lesion in the tibial stress fracture and only remodeling activity without evidence of cortical lesions in the enthesopathy processes.

  5. Hericium erinaceus (Lion’s Mane) mushroom extracts inhibit metastasis of cancer cells to the lung in CT-26 colon cancer-transplanted mice

    USDA-ARS?s Scientific Manuscript database

    We investigated the anti-metastatic activity of four Hericium erinaceus edible mushroom extracts using CT-26 murine colon carcinoma cells as an indicator of inhibition of cell migration to the lung. Hot water (HWE) and microwaved 50% ethanol (MWE) extracts of Hericium erinaceus strongly elicited ca...

  6. Understanding the free energy barrier and multiple timescale dynamics of charge separation in organic photovoltaic cells.

    PubMed

    Yan, Yaming; Song, Linze; Shi, Qiang

    2018-02-28

    By employing several lattice model systems, we investigate the free energy barrier and real-time dynamics of charge separation in organic photovoltaic (OPV) cells. It is found that the combined effects of the external electric field, entropy, and charge delocalization reduce the free energy barrier significantly. The dynamic disorder reduces charge carrier delocalization and results in the increased charge separation barrier, while the effect of static disorder is more complicated. Simulation of the real-time dynamics indicates that the free charge generation process involves multiple time scales, including an ultrafast component within hundreds of femtoseconds, an intermediate component related to the relaxation of the hot charge transfer (CT) state, and a slow component on the time scale of tens of picoseconds from the thermally equilibrated CT state. Effects of hot exciton dissociation as well as its dependence on the energy offset between the Frenkel exciton and the CT state are also analyzed. The current results indicate that only a small energy offset between the band gap and the lowest energy CT state is needed to achieve efficient free charge generation in OPV devices, which agrees with recent experimental findings.

  7. Understanding the free energy barrier and multiple timescale dynamics of charge separation in organic photovoltaic cells

    NASA Astrophysics Data System (ADS)

    Yan, Yaming; Song, Linze; Shi, Qiang

    2018-02-01

    By employing several lattice model systems, we investigate the free energy barrier and real-time dynamics of charge separation in organic photovoltaic (OPV) cells. It is found that the combined effects of the external electric field, entropy, and charge delocalization reduce the free energy barrier significantly. The dynamic disorder reduces charge carrier delocalization and results in the increased charge separation barrier, while the effect of static disorder is more complicated. Simulation of the real-time dynamics indicates that the free charge generation process involves multiple time scales, including an ultrafast component within hundreds of femtoseconds, an intermediate component related to the relaxation of the hot charge transfer (CT) state, and a slow component on the time scale of tens of picoseconds from the thermally equilibrated CT state. Effects of hot exciton dissociation as well as its dependence on the energy offset between the Frenkel exciton and the CT state are also analyzed. The current results indicate that only a small energy offset between the band gap and the lowest energy CT state is needed to achieve efficient free charge generation in OPV devices, which agrees with recent experimental findings.

  8. Hot spot detection, segmentation, and identification in PET images

    NASA Astrophysics Data System (ADS)

    Blaffert, Thomas; Meetz, Kirsten

    2006-03-01

    Positron Emission Tomography (PET) images provide functional or metabolic information from areas of high concentration of [18F]fluorodeoxyglucose (FDG) tracer, the "hot spots". These hot spots can be easily detected by the eye, but delineation and size determination required e.g. for diagnosis and staging of cancer is a tedious task that demands for automation. The approach for such an automated hot spot segmentation described in this paper comprises three steps: A region of interest detection by the watershed transform, a heart identification by an evaluation of scan lines, and the final segmentation of hot spot areas by a local threshold. The region of interest detection is the essential step, since it localizes the hot spot identification and the final segmentation. The heart identification is an example of how to differentiate between hot spots. Finally, we demonstrate the combination of PET and CT data. Our method is applicable to other techniques like SPECT.

  9. Microstructure of Sinter Deposit Formed at Hot Springs in West Sumatera

    NASA Astrophysics Data System (ADS)

    Putra, A.; Inanda, D. Y.; Buspa, F.; Salim, A. F.

    2018-03-01

    Sinter deposit emerged and spread at several hot springs in West Sumatera is divided into three types, they are full silica, half silica-carbonate and full carbonate. This work intends to investigate the characteristic of each type by its crystalline structure and morphology and its correlation to surface temperature. The research is focused on Sapan Maluluang hot spring (full silica), Garara hot spring (half silica-carbonate) and Bawah Kubang hot spring (full carbonate). Crystalline structure is analyzed by X-Ray Diffraction (XRD) methods, it showed that deposit from Sapan Maluluang has opal-A structure, Garara has opal-CT structure and Bawah Kubang has crystalline structure. The Scanning Electron Microscopy (SEM) methods is applied to describe its morphology surface, in which spherical, almost rounded and irregular textured was formed at each deposit, respectively. Surface temperature of hot spring also has given impact on deposit texture.

  10. Turbine Engine Hot Section Technology, 1985

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The Turbine Engine Section Technology (HOST) Project Office of the Lewis Research Center sponsored a workshop to discuss current research pertinent to turbine engine hot section durability problems. Presentations were made concerning hot section environment and the behavior of combustion liners, turbine blades, and turbine vanes.

  11. 46 CFR 63.25-3 - Electric hot water supply boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Electric hot water supply boilers. 63.25-3 Section 63.25... water supply boilers. (a) Electric hot water supply boilers that have a capacity not greater than 454... section except the periodic testing required by paragraph (j) of this section. Electric hot water supply...

  12. Ga-68-DOTATOC: Feasibility of high throughput screening by small animal PET using a clinical high-resolution PET/CT scanner

    NASA Astrophysics Data System (ADS)

    Hofmann, Michael; Weitzel, Thilo; Krause, Thomas

    2006-12-01

    As radio peptide tracers have been developed in recent years for the high sensitive detection of neuroendocrine tumors, still the broad application of other peptides to breast and prostate cancer is missing. A rapid screening of new peptides can, in theory, be based on in vivo screening in animals by PET/CT. To test this hypothesis and to asses the minimum screening time needed per animal, we used the application of Ga-68-DOTATOC PET/CT in rats as test system. The Ga-68-DOTATOC yields in a hot spot imaging with minimal background. To delineate liver and spleen, we performed PET/CT of 10 animals on a SIEMENS Biograph 16 LSO HIGHREZ after intravenous injection of 1.5 MBq Ga-68-DOTATOC per animal. Animals were mounted in an '18 slot' holding device and scanned for a single-bed position. The emission times for the PET scan was varied from 1 to 20 min. The images were assessed first for "PET only" and afterwards in PET/CT fusion mode. The detection of the two organs was good at emission times down to 1 min in PET/CT fusion mode. In the "PET only" scans, the liver was clearly to be identified down to 1 min emission in all animals. But the spleen could only be delineated only by 1 min of emission in the PET/CT-fusion mode. In conclusion the screening of "hot spot" enriching peptides is feasible. "PET only" is in terms of delineation of small organs by far inferior to PET/CT fusion. If animal tumors are above a diameter of 10 mm small, animal PET/CT using clinical high resolution scanners will enable rapid screening. Even the determination of bio-distributions becomes feasible by using list mode tools. The time for the whole survey of 18 animals including anesthesia, preparation and mounting was approximately 20 min. By use of several holding devices mounted simultaneously, a survey time of less than 1 h for 180 animals can be expected.

  13. Cutaneous sarcoidosis evaluated by FDG PET.

    PubMed

    Li, Yuxin; Berenji, Gholam R

    2011-07-01

    A 50-year-old man presented with initial complaints of diffuse skin pain and pruritus. Physical examination revealed scattered skin plaques and subcutaneous nodules with mild tenderness throughout the body. Skin biopsy demonstrated noncaseating epithelioid granulomas. Patient soon developed cough, fever with hot flashes, and shortness of breath on exertion. FDG PET/CT demonstrated diffuse cutaneous involvement throughout the body. Follow-up FDG PET/CT after treatment revealed a decrease in FDG uptake suggesting a good response to therapy.

  14. Impact of view reduction in CT on radiation dose for patients

    NASA Astrophysics Data System (ADS)

    Parcero, E.; Flores, L.; Sánchez, M. G.; Vidal, V.; Verdú, G.

    2017-08-01

    Iterative methods have become a hot topic of research in computed tomography (CT) imaging because of their capacity to resolve the reconstruction problem from a limited number of projections. This allows the reduction of radiation exposure on patients during the data acquisition. The reconstruction time and the high radiation dose imposed on patients are the two major drawbacks in CT. To solve them effectively we adapted the method for sparse linear equations and sparse least squares (LSQR) with soft threshold filtering (STF) and the fast iterative shrinkage-thresholding algorithm (FISTA) to computed tomography reconstruction. The feasibility of the proposed methods is demonstrated numerically.

  15. Evaluation of the impact of metal artifacts in CT-based attenuation correction of positron emission tomography scans

    NASA Astrophysics Data System (ADS)

    Wu, Jay; Shih, Cheng-Ting; Chang, Shu-Jun; Huang, Tzung-Chi; Chen, Chuan-Lin; Wu, Tung Hsin

    2011-08-01

    The quantitative ability of PET/CT allows the widespread use in clinical research and cancer staging. However, metal artifacts induced by high-density metal objects degrade the quality of CT images. These artifacts also propagate to the corresponding PET image and cause a false increase of 18F-FDG uptake near the metal implants when the CT-based attenuation correction (AC) is performed. In this study, we applied a model-based metal artifact reduction (MAR) algorithm to reduce the dark and bright streaks in the CT image and compared the differences between PET images with the general CT-based AC (G-AC) and the MAR-corrected-CT AC (MAR-AC). Results showed that the MAR algorithm effectively reduced the metal artifacts in the CT images of the ACR flangeless phantom and two clinical cases. The MAR-AC also removed the false-positive hot spot near the metal implants of the PET images. We conclude that the MAR-AC could be applied in clinical practice to improve the quantitative accuracy of PET images. Additionally, further use of PET/CT fusion images with metal artifact correction could be more valuable for diagnosis.

  16. Relationship of Soluble Grape-Derived Proteins to Condensed Tannin Extractability during Red Wine Fermentation.

    PubMed

    Springer, Lindsay F; Chen, Lei-An; Stahlecker, Avery C; Cousins, Peter; Sacks, Gavin L

    2016-11-02

    In red winemaking, the extractability of condensed tannins (CT) can vary considerably even under identical fermentation conditions, and several explanations for this phenomenon have been proposed. Recent work has demonstrated that grape pathogenesis-related proteins (PRPs) may limit retention of CT added to finished wines, but their relevance to CT extractability has not been evaluated. In this work, Vitis vinifera and interspecific hybrids (Vitis ssp.) from both hot and cool climates were vinified under small-scale, controlled conditions. The final CT concentration in wine was well modeled from initial grape tannin and juice protein concentrations using the Freundlich equation (r 2 = 0.686). In follow-up experiments, separation and pretreatment of juice by bentonite, heating, freezing, or exogenous tannin addition reduced protein concentrations in juices from two grape varieties. The bentonite treatment also led to greater wine CT for one of the varieties, indicating that prefermentation removal of grape protein may be a viable approach to increasing wine CT.

  17. Evaluation of physiological response and performance by supplementation of Curcuma longa in broiler feed under hot humid tropical climate.

    PubMed

    Oke, O E

    2018-06-01

    Dietary manipulation has been seen as one of the practical ways to ameliorate the adverse effects of thermal stress in the hot humid tropical climate. In order to investigate the influence of Curcuma longa (turmeric) rhizome powder on physiological responses and performance under hot humid tropical climate, 240 broiler chicks were randomly assigned to four dietary treatments having four replicates of 15 birds each in a complete randomized design. Broiler birds were fed basal diets and supplemented with 0 (CT), 4 (TG), 8 (FT), and 12 g (SG) of turmeric powder/kg of diet for 8 weeks. Data were collected weekly on feed intake and body weights. Blood samples were collected from eight birds per treatment at week 4 (starter phase) and week 8 (finisher phase) of the experiment for the determination of plasma 3,5,3'-triiodothyronine (T 3 ), superoxide dismutase (SOD), malondialdehyde (MDA). Rectal temperature of the birds was also taken. At 56 days of age, eight birds from each treatment were slaughtered for the determination of relative organ weights. Results showed that the final weights of the birds in FT were significantly higher than those of the birds in TG, SG, and CT. The weight gain of the birds in FT was higher than those of the birds in SG while those of SG were higher than those of TG whose values were higher than that of CT. The feed conversion ratio of the broiler chickens in CT was higher (P < 0.05) than those of other treatment groups while the birds in FT and SG had similar feed conversion ratios. SOD of birds fed turmeric rhizome powder was higher than the birds in the control group at both starter and finisher phases. Furthermore, MDA of the birds in FT was lower than those of the birds in the other treatment groups at the finisher phase. Plasma T 3 was higher in the birds fed turmeric at the finisher phase than chickens in the control group. There was no difference in the rectal temperatures of the birds. To conclude, turmeric rhizome powder improved the physiological response and performance of broiler chicken under hot humid tropical climate in a dose-dependent characteristic and the optimum supplementation rate of 8 g/kg of diet was recorded.

  18. A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics.

    PubMed

    Raylman, Raymond R; Van Kampen, Will; Stolin, Alexander V; Gong, Wenbo; Jaliparthi, Gangadhar; Martone, Peter F; Smith, Mark F; Sarment, David; Clinthorne, Neal H; Perna, Mark

    2018-04-01

    Application of advanced imaging techniques, such as PET and x ray CT, can potentially improve detection of breast cancer. Unfortunately, both modalities have challenges in the detection of some lesions. The combination of the two techniques, however, could potentially lead to an overall improvement in diagnostic breast imaging. The purpose of this investigation is to test the basic performance of a new dedicated breast-PET/CT. The PET component consists of a rotating pair of detectors. Its performance was evaluated using the NEMA NU4-2008 protocols. The CT component utilizes a pulsed x ray source and flat panel detector mounted on the same gantry as the PET scanner. Its performance was assessed using specialized phantoms. The radiation dose to a breast during CT imaging was explored by the measurement of free-in-air kerma and air kerma measured at the center of a 16 cm-diameter PMMA cylinder. Finally, the combined capabilities of the system were demonstrated by imaging of a micro-hot-rod phantom. Overall, performance of the PET component is comparable to many pre-clinical and other dedicated breast-PET scanners. Its spatial resolution is 2.2 mm, 5 mm from the center of the scanner using images created with the single-sliced-filtered-backprojection algorithm. Peak NECR is 24.6 kcps; peak sensitivity is 1.36%; the scatter fraction is 27%. Spatial resolution of the CT scanner is 1.1 lp/mm at 10% MTF. The free-in-air kerma is 2.33 mGy, while the PMMA-air kerma is 1.24 mGy. Finally, combined imaging of a micro-hot-rod phantom illustrated the potential utility of the dual-modality images produced by the system. The basic performance characteristics of a new dedicated breast-PET/CT scanner are good, demonstrating that its performance is similar to current dedicated PET and CT scanners. The potential value of this system is the capability to produce combined duality-modality images that could improve detection of breast disease. The next stage in development of this system is testing with more advanced phantoms and human subjects. © 2018 American Association of Physicists in Medicine.

  19. 29 CFR 1915.503 - Precautions for hot work.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Precautions for hot work. 1915.503 Section 1915.503 Labor... Employment § 1915.503 Precautions for hot work. (a) General requirements—(1) Designated Areas. The employer may designate areas for hot work in sites such as vessels, vessel sections, fabricating shops, and...

  20. 29 CFR 1915.503 - Precautions for hot work.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Precautions for hot work. 1915.503 Section 1915.503 Labor... Employment § 1915.503 Precautions for hot work. (a) General requirements—(1) Designated Areas. The employer may designate areas for hot work in sites such as vessels, vessel sections, fabricating shops, and...

  1. 29 CFR 1915.503 - Precautions for hot work.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Precautions for hot work. 1915.503 Section 1915.503 Labor... Employment § 1915.503 Precautions for hot work. (a) General requirements—(1) Designated Areas. The employer may designate areas for hot work in sites such as vessels, vessel sections, fabricating shops, and...

  2. 29 CFR 1915.503 - Precautions for hot work.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Precautions for hot work. 1915.503 Section 1915.503 Labor... Employment § 1915.503 Precautions for hot work. (a) General requirements—(1) Designated Areas. The employer may designate areas for hot work in sites such as vessels, vessel sections, fabricating shops, and...

  3. 29 CFR 1915.503 - Precautions for hot work.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Precautions for hot work. 1915.503 Section 1915.503 Labor... Employment § 1915.503 Precautions for hot work. (a) General requirements—(1) Designated Areas. The employer may designate areas for hot work in sites such as vessels, vessel sections, fabricating shops, and...

  4. 2. SECTIONAL BOILER '#4 IDEAL RED FLASH.' Hot Springs ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. SECTIONAL BOILER '#4 IDEAL RED FLASH.' - Hot Springs National Park, Bathhouse Row, Ozark Bathhouse: Mechanical & Piping Systems, State Highway 7, 1 mile north of U.S. Highway 70, Hot Springs, Garland County, AR

  5. 46. VIEW LOOKING NORTHEAST OF CONDENSER NUMBER 2 (LEFT BACKGROUND) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. VIEW LOOKING NORTHEAST OF CONDENSER NUMBER 2 (LEFT BACKGROUND) AND MOTOR FOR PUMPING CONDENSER HOT WELL (LOWER CENTER OF PHOTOGRAPH). SPENT STEAM EXHAUSTED FROM THE TURBINE WAS CONDENSED BY A SPRAY OF BRACKISH WATER. THIS CREATED A PARTIAL VACUUM WHICH IMPROVED TURBINE EFFICIENCY. THE MIXTURE OF CONDENSED STEAM AND COOL BRACKISH WATER FELL TO THE BOTTOM OF THE CONDENSER INTO A HOT WELL. FROM THE WELL IT WAS PUMPED TO THE MAIN DISCHARGE FLUME. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  6. Prevalence of ligamentum arteriosum calcification on multi-section spiral CT and digital radiography.

    PubMed

    Hong, Gil-Sun; Goo, Hyun Woo; Song, Jae-Woo

    2012-06-01

    To investigate the prevalence of ligamentum arteriosum calcification (LAC) on multi-section spiral CT and digital radiography. Five hundred and eight children and 232 adults who performed multi-section chest CT were included in this study and were divided into nine age groups: A (0-5 years), B (6-10 years), C (11-15 years), D (16-20 years), E (21-30 years), F (31-40 years), G (41-50 years), H (51-60 years), and I (61-70 years). Two radiologists assessed the presence of LAC on axial and coronal CT images, defined as focal calcific density on both or on one plane with attenuation >100 Hounsfield unit. The prevalence of LAC on CT was compared between children and adults, and between unenhanced and enhanced CT in children. The prevalence of LAC on digital radiography was evaluated in 476 children. The prevalence of definite LAC on unenhanced multi-section CT was significantly higher in children (37.8 %) than in adults (11.2 %) (P < 0.001), with prevalences in groups: A through I of 35.8, 48.7, 35.1, 28.6, 25.0, 10.2, 15.5, 7.8, and 5.6 %, respectively. The prevalences of indeterminate LAC in age groups A-I on unenhanced multi-section CT were 4.5, 12.8, 8.1, 19.0, 0.0, 0.0, 0.0, 2.0, and 1.9 %. In children, the prevalence of LAC was significantly higher on unenhanced than on enhanced CT (37.8 vs. 16.4 %, P < 0.001). The prevalence of LAC on digital radiography was 3.6 % in children. LAC is frequently observed in children and adults on multi-section spiral CT, more frequently than previously reported. Compared with that on multi-section spiral CT, the prevalence of LAC on digital radiography is substantially low.

  7. CT perfusion for determination of pharmacologically mediated blood flow changes in an animal tumor model.

    PubMed

    Hakimé, Antoine; Peddi, Himaja; Hines-Peralta, Andrew U; Wilcox, Carol J; Kruskal, Jonathan; Lin, Shezhang; de Baere, Thierry; Raptopoulos, Vassilios D; Goldberg, S Nahum

    2007-06-01

    To prospectively compare single- and multisection computed tomographic (CT) perfusion for tumor blood flow determination in an animal model. All animal protocols and experiments were approved by the institutional animal care and use committee before the study was initiated. R3230 mammary adenocarcinoma was implanted in 11 rats. Tumors (18-20 mm) were scanned with dynamic 16-section CT at baseline and after administration of arsenic trioxide, which is known to cause acute reduction in blood flow. The concentration of arsenic was titrated (0-6 mg of arsenic per kilogram of body weight) to achieve a defined blood flow reduction (0%-75%) from baseline levels at 60 minutes, as determined with correlative laser Doppler flowmetry. The mean blood flow was calculated for each of four 5-mm sections that covered the entire tumor, as well as for the entire tumor after multiple sections were processed. Measurements obtained with both methods were correlated with laser Doppler flowmetry measurements. Interobserver agreement was determined for two blinded radiologists, who calculated the percentage of blood flow reduction for the "most representative" single sections at baseline and after arsenic administration. These results were compared with the interobserver variability of the same radiologists obtained by summing blood flow changes for the entire tumor volume. Overall correlations for acute blood flow reduction were demonstrated between laser Doppler flowmetry and the two CT perfusion approaches (single-section CT, r=0.85 and r(2)=0.73; multisection CT, r=0.93 and r(2)=0.87; pooled data, P=.01). CT perfusion disclosed marked heterogeneity of blood flow, with variations of 36% +/- 13 between adjacent 5-mm sections. Given these marked differences, interobserver agreement was much lower for single-section CT (standard deviation, 0.22) than for multisection CT (standard deviation, 0.10; P=.01). Multisection CT perfusion techniques may provide an accurate and more reproducible method of tumor perfusion surveillance than comparison of single representative tumor sections. (c) RSNA, 2007.

  8. Novel Thin Film Sensor Technology for Turbine Engine Hot Section Components

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D.; Fralick, Gustave C.

    2007-01-01

    Degradation and damage that develops over time in hot section components can lead to catastrophic failure of the turbine section of aircraft engines. A range of thin film sensor technology has been demonstrated enabling on-component measurement of multiple parameters either individually or in sensor arrays including temperature, strain, heat flux, and flow. Conductive ceramics are beginning to be investigated as new materials for use as thin film sensors in the hot section, leveraging expertise in thin films and high temperature materials. The current challenges are to develop new sensor and insulation materials capable of withstanding the extreme hot section environment, and to develop techniques for applying sensors onto complex high temperature structures for aging studies of hot propulsion materials. The technology research and development ongoing at NASA Glenn Research Center for applications to future aircraft, launch vehicles, space vehicles, and ground systems is outlined.

  9. Solid oxide fuel cell power plant having a fixed contact oxidation catalyzed section of a multi-section cathode air heat exchanger

    DOEpatents

    Saito, Kazuo; Lin, Yao

    2015-02-17

    The multi-section cathode air heat exchanger (102) includes at least a first heat exchanger section (104), and a fixed contact oxidation catalyzed section (126) secured adjacent each other in a stack association. Cool cathode inlet air flows through cool air channels (110) of the at least first (104) and oxidation catalyzed sections (126). Hot anode exhaust flows through hot air channels (124) of the oxidation catalyzed section (126) and is combusted therein. The combusted anode exhaust then flows through hot air channels (112) of the first section (104) of the cathode air heat exchanger (102). The cool and hot air channels (110, 112) are secured in direct heat exchange relationship with each other so that temperatures of the heat exchanger (102) do not exceed 800.degree. C. to minimize requirements for using expensive, high-temperature alloys.

  10. CT-guided percutaneous fine-needle aspiration biopsy of the inferior vena cava wall: a posterior coaxial approach.

    PubMed

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L

    2010-02-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  11. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.de; Bilecen, Deniz; Baumhoer, Daniel

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of themore » patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.« less

  12. Micro-CT Sections and Histological Sections of Mouse Skull Defects Implanted with Cartilage Grown in a Rotating Bioreactor

    NASA Astrophysics Data System (ADS)

    Duke, P. J.; Montufar-Solis, D.; Nguyen, H. C.; Cody, D. D.

    2008-06-01

    Using cartilage to replace/repair bone is advantageous as no scaffolding is required to form the implant which disappears as bone is formed during the endochondral process. Previously, we demonstrated that cartilage spheroids, grown in a rotating bioreactor, (Synthecon, Inc.) and implanted into a 2 mm skull defect, contributed to healing of the defect. In this report, skulls with or without implants were subjected to microCT scans, and sections from these scans were compared to histological sections of the defect region of demineralized skulls from the same experiment. The area of the defect staining for bone in histological sections of demineralized skulls was the same region shown as mineralized in CT sections. Defects without implants were shown in serial CT sections and histological sections, to be incompletely healed. This study demonstrates that microCT scans are an important corollary to histological studies evaluating the use of implants in healing of bony defects. Supported in part by NIH/NIDCR Training Grant T35 DE07252 and by Cancer Center Support Grant (CA-16672).

  13. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms.

    PubMed

    Bieniosek, Matthew F; Lee, Brian J; Levin, Craig S

    2015-10-01

    Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial "Micro Deluxe" phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. This work shows that 3D printed phantoms can be functionally equivalent to commercially available phantoms. They are a viable option for quickly distributing and fabricating low cost, customized phantoms.

  14. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qayyum, F; Armato, S; Straus, C

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volumemore » of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology.« less

  15. CT Scans - Multiple Languages

    MedlinePlus

    ... Tomography) Scan - العربية (Arabic) Bilingual PDF Health Information Translations Chinese, Simplified (Mandarin dialect) (简体中文) Expand Section CT ( ... Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chinese, Traditional (Cantonese dialect) (繁體中文) Expand Section CT ( ...

  16. 76 FR 22817 - Approval and Promulgation of Air Quality Implementation Plans; South Carolina; Update to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-25

    ... Manufacturing'' 5. ``Section VI--Hot Mix Asphalt Manufacturing'' 6. ``Section VII--Metal Refining;'' [[Page... Industries 1. ``Section III--Kraft Pulp and Paper Manufacturing Plants'' 2. ``Section VI--Hot Mix Asphalt... Manufacturing'' 3. ``Section XI--Total Reduced Sulfur Emissions of Kraft Pulp Mills;'' viii. Regulation 62.5...

  17. FDG-PET, CT, MRI for diagnosis of local residual or recurrent nasopharyngeal carcinoma, which one is the best? A systematic review.

    PubMed

    Liu, Tao; Xu, Wen; Yan, Wei-Li; Ye, Ming; Bai, Yong-Rui; Huang, Gang

    2007-12-01

    To perform a systematic review to compare FDG-PET, CT, and MRI imaging for diagnosis of local residual or recurrent nasopharyngeal carcinoma. MEDLINE, EMBASE, the CBMdisc databases and some other databases were searched for relevant original articles published from January 1990 to June 2007. Inclusion criteria were as follows: Articles were reported in English or Chinese; FDG-PET, CT, or MRI was used to detect local residual or recurrent nasopharyngeal carcinoma; histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months were the reference standard. Two reviewers independently extracted data. A software called "Meta-DiSc" was used to obtain pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the Q* index. Twenty-one articles fulfilled all inclusion criteria. The pooled sensitivity estimates for PET (95%) were significantly higher than CT (76%) (P<0.001) and MRI (78%) (P<0.001). The pooled specificity estimates for PET (90%) were significantly higher than CT (59%) (P<0.001) and MRI (76%) (P<0.001). The pooled DOR estimates for PET (96.51) were significantly higher than CT (7.01) (P<0.001) and MRI (8.68) (P<0.001). SROC curve for FDG-PET showed better diagnostic accuracy than CT and MRI. The Q* index for PET (0.92) was significantly higher than CT (0.72) (P<0.001) and MRI (0.76) (P<0.01). For PET, the sensitivity and diagnostic OR for using qualitative analysis were significantly higher than using both qualitative and quantitative analyses (P<0.01). For CT, the sensitivity, specificity, diagnostic OR, and the Q* index for dual-section helical and multi-section helical were all significantly higher than nonhelical and single-section helical (P<0.01). And the sensitivity for 'section thickness <5 mm' was significantly lower than ' =5 mm' (P<0.01), while the specificity was significantly higher (P<0.01). For MRI, there were no significant differences found between magnetic field strength <1.5 and > or =1.5 T (P>0.05). FDG-PET was the best modality for diagnosis of local residual or recurrent nasopharyngeal carcinoma. The type of analysis for PET imaging and the section thickness for CT would affect the diagnostic results. Dual-section helical and multi-section helical CT were better than nonhelical and single-section helical CT.

  18. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    PubMed

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  19. Standard-, Reduced-, and No-Dose Thin-Section Radiologic Examinations: Comparison of Capability for Nodule Detection and Nodule Type Assessment in Patients Suspected of Having Pulmonary Nodules.

    PubMed

    Ohno, Yoshiharu; Koyama, Hisanobu; Yoshikawa, Takeshi; Kishida, Yuji; Seki, Shinichiro; Takenaka, Daisuke; Yui, Masao; Miyazaki, Mitsue; Sugimura, Kazuro

    2017-08-01

    Purpose To compare the capability of pulmonary thin-section magnetic resonance (MR) imaging with ultrashort echo time (UTE) with that of standard- and reduced-dose thin-section computed tomography (CT) in nodule detection and evaluation of nodule type. Materials and Methods The institutional review board approved this study, and written informed consent was obtained from each patient. Standard- and reduced-dose chest CT (60 and 250 mA) and MR imaging with UTE were used to examine 52 patients; 29 were men (mean age, 66.4 years ± 7.3 [standard deviation]; age range, 48-79 years) and 23 were women (mean age, 64.8 years ± 10.1; age range, 42-83 years). Probability of nodule presence was assessed for all methods with a five-point visual scoring system. All nodules were then classified as missed, ground-glass, part-solid, or solid nodules. To compare nodule detection capability of the three methods, consensus for performances was rated by using jackknife free-response receiver operating characteristic analysis, and κ analysis was used to compare intermethod agreement for nodule type classification. Results There was no significant difference (F = 0.70, P = .59) in figure of merit between methods (standard-dose CT, 0.86; reduced-dose CT, 0.84; MR imaging with UTE, 0.86). There was no significant difference in sensitivity between methods (standard-dose CT vs reduced-dose CT, P = .50; standard-dose CT vs MR imaging with UTE, P = .50; reduced-dose CT vs MR imaging with UTE, P >.99). Intermethod agreement was excellent (standard-dose CT vs reduced-dose CT, κ = 0.98, P < .001; standard-dose CT vs MR imaging with UTE, κ = 0.98, P < .001; reduced-dose CT vs MR imaging with UTE, κ = 0.99, P < .001). Conclusion Pulmonary thin-section MR imaging with UTE was useful in nodule detection and evaluation of nodule type, and it is considered at least as efficacious as standard- or reduced-dose thin-section CT. © RSNA, 2017 Online supplemental material is available for this article.

  20. 36. VIEW EAST OF WASTE HEAT RECOVERY SYSTEM IN BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. VIEW EAST OF WASTE HEAT RECOVERY SYSTEM IN BUILDING 43A; THIS WAS PART OF A SYSTEM WHICH PROVIDED HOT WATER FOR OFFICE AND FACTORY BUILDING HEATING IN THE WEST PLANT; NOTE FACTORY WHISTLE TIMER ON TOP OF HEAT EXCHANGER - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT

  1. Advanced high temperature instrument for hot section research applications

    NASA Technical Reports Server (NTRS)

    Englund, D. R.; Seasholtz, R. G.

    1989-01-01

    Programs to develop research instrumentation for use in turbine engine hot sections are described. These programs were initiated to provide improved measurements capability as support for a multidisciplinary effort to establish technology leading to improved hot section durability. Specific measurement systems described here include heat flux sensors, a dynamic gas temperature measuring system, laser anemometry for hot section applications, an optical system for viewing the interior of a combustor during operation, thin film sensors for surface temperature and strain measurements, and high temperature strain measuring systems. The state of development of these sensors and measuring systems is described, and, in some cases, examples of measurements made with these instruments are shown. Work done at the NASA Lewis Research Center and at various contract and grant facilities is covered.

  2. Evaluation of radiographic, computed tomographic, and cadaveric anatomy of the head of boa constrictors.

    PubMed

    Banzato, Tommaso; Russo, Elisa; Di Toma, Anna; Palmisano, Giuseppe; Zotti, Alessandro

    2011-12-01

    To evaluate the radiographic, computed tomographic (CT), and cadaveric anatomy of the head of boa constrictors. 4 Boa constrictor imperator cadavers. Cadavers weighed 3.4 to 5.6 kg and had a body length ranging from 189 to 221 cm. Radiographic and CT images were obtained with a high-detail screen-film combination, and conventional CT was performed with a slice thickness of 1.5 mm. Radiographic images were obtained in ventrodorsal, dorsoventral, and left and right laterolateral recumbency; CT images were obtained with the animals positioned in ventral recumbency directly laying on a plastic support. At the end of the radiographic and CT imaging session, 2 heads were sectioned following a stratigraphic approach; the other 2, carefully maintained in the same position on the plastic support, were moved into a freezer (-20°C) until completely frozen and then sectioned into 3-mm slices, respecting the imaging protocol. The frozen sections were cleaned and then photographed on each side. Anatomic structures were identified and labeled on gross anatomic images and on the corresponding CT or radiographic image with the aid of available literature. Radiographic and CT images provided high detail for visualization of bony structures; soft tissues were not easily identified on radiographic and CT images. Results provide an atlas of stratigraphic and cross-sectional gross anatomy and radiographic and CT anatomy of the heads of boa constrictors that might be useful in the interpretation of any imaging modality in this species.

  3. Three-rooted premolar analyzed by high-resolution and cone beam CT.

    PubMed

    Marca, Caroline; Dummer, Paul M H; Bryant, Susan; Vier-Pelisser, Fabiana Vieira; Só, Marcus Vinicius Reis; Fontanella, Vania; Dutra, Vinicius D'avila; de Figueiredo, José Antonio Poli

    2013-07-01

    The aim of this study was to analyze the variations in canal and root cross-sectional area in three-rooted maxillary premolars between high-resolution computed tomography (μCT) and cone beam computed tomography (CBCT). Sixteen extracted maxillary premolars with three distinct roots and fully formed apices were scanned using μCT and CBCT. Photoshop CS software was used to measure root and canal cross-sectional areas at the most cervical and the most apical points of each root third in images obtained using the two tomographic computed (CT) techniques, and at 30 root sections equidistant from both root ends using μCT images. Canal and root areas were compared between each method using the Student t test for paired samples and 95 % confidence intervals. Images using μCT were sharper than those obtained using CBCT. There were statistically significant differences in mean area measurements of roots and canals between the μCT and CBCT techniques (P < 0.05). Root and canal areas had similar variations in cross-sectional μCT images and became proportionally smaller in a cervical to apical direction as the cementodentinal junction was approached, from where the area then increased apically. Although variation was similar in the roots and canals under study, CBCT produced poorer image details than μCT. Although CBCT is a strong diagnosis tool, it still needs improvement to provide accuracy in details of the root canal system, especially in cases with anatomical variations, such as the three-rooted maxillary premolars.

  4. Normal cross-sectional anatomy of the bovine digit: comparison of computed tomography and limb anatomy.

    PubMed

    Raji, A R; Sardari, K; Mohammadi, H R

    2008-06-01

    The purpose of this study was to define the structures of the digits and hoof in Holstein dairy cattle by using computed tomography scan (CT scan). Transverse, sagittal and dorsoplantar CT images of two isolated cattle cadaver digits were obtained using a Siemens ARTX2 Somatom. The CT images were compared to corresponding frozen cross-sections. Relevant anatomical structures were identified and labelled at each level. The CT images provided anatomical detail of the digits and hoof in Holstein dairy cattle. Transversal images provided excellent depiction of anatomical structures when compared to corresponding frozen cross-sections. The information presented in this paper would serve as an initial reference to the evaluation of CT images of the digits and hoof in Holstein dairy cattle.

  5. 116. ARAI Details of hot cell section of building ARA626. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. ARA-I Details of hot cell section of building ARA-626. Shows manipulator openings in operating face of hot cell, start/stop buttons, and other details. Norman Engineering Company 961/area/SF-626-E-6. Date: January 1959. Ineel index code no. 068-0626-10-613-102731. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  6. Detection of Sentinel Lymph Nodes in Gynecologic Tumours by Planar Scintigraphy and SPECT/CT

    PubMed Central

    Kraft, Otakar; Havel, Martin

    2012-01-01

    Objective: Assess the role of planar lymphoscintigraphy and fusion imaging of SPECT/CT in sentinel lymph node (SLN) detection in patients with gynecologic tumours. Material and Methods: Planar scintigraphy and hybrid modality SPECT/CT were performed in 64 consecutive women with gynecologic tumours (mean age 53.6 with range 30-77 years): 36 pts with cervical cancer (Group A), 21 pts with endometrial cancer (Group B), 7 pts with vulvar carcinoma (Group C). Planar and SPECT/CT images were interpreted separately by two nuclear medicine physicians. Efficacy of these two techniques to image SLN were compared. Results: Planar scintigraphy did not image SLN in 7 patients (10.9%), SPECT/CT was negative in 4 patients (6.3%). In 35 (54.7%) patients the number of SLNs captured on SPECT/CT was higher than on planar imaging. Differences in detection of SLN between planar and SPECT/CT imaging in the group of all 64 patients are statistically significant (p<0.05). Three foci of uptake (1.7% from totally visible 177 foci on planar images) in 2 patients interpreted on planar images as hot LNs were found to be false positive non-nodal sites of uptake when further assessed on SPECT/CT. SPECT/CT showed the exact anatomical location of all visualised sentinel nodes. Conclusion: In some patients with gynecologic cancers SPECT/CT improves detection of sentinel lymph nodes. It can image nodes not visible on planar scintigrams, exclude false positive uptake and exactly localise pelvic and paraaortal SLNs. It improves anatomic localization of SLNs. Conflict of interest:None declared. PMID:23486989

  7. Thin-Section Computed Tomography Manifestations During Convalescence and Long-Term Follow-Up of Patients with Severe Acute Respiratory Syndrome (SARS).

    PubMed

    Wu, Xiaohua; Dong, Dawei; Ma, Daqing

    2016-08-08

    BACKGROUND SARS is not only an acute disease, but also leads to long-term impaired lung diffusing capacity in some survivors. However, there is a paucity of data regarding long-term CT findings in survivors after SARS. The aim of this study was to assess the changes in lung function and lung thin-section computed tomography (CT) features in patients recovering from severe acute respiratory syndrome (SARS), especially the dynamic changes in ground-glass opacity (GGO). MATERIAL AND METHODS Clinical and radiological data from 11 patients with SARS were collected. The serial follow-up thin-section CTs were evaluated at 3, 6, and 84 months after SARS presentation. The distribution and predominant thin-section CT findings of lesions were evaluated. RESULTS The extent of the lesions on the CT scans of the 11 patients decreased at 6 and 84 months compared to 3 months. The number of segments involved on 84-month follow-up CTs was less than those at 6 months (P<0.05). The predominant thin-section CT manifestation at 84 months (intralobular and interlobular septal thickening) was different than that at 6 months, at which GGO was predominant. CONCLUSIONS During convalescence after SARS, GGO and intralobular and interlobular septal thickening were the main thin-section CT manifestation. Intralobular and interlobular septal thickening predominated over GGO at 84 months.

  8. Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Jia; Christner, Jodie A.; Duan Xinhui

    2012-11-15

    Purpose: To estimate attenuation using cross sectional CT images and scanned projection radiograph (SPR) images in a series of thorax and abdomen phantoms. Methods: Attenuation was quantified in terms of a water cylinder with cross sectional area of A{sub w} from both the CT and SPR images of abdomen and thorax phantoms, where A{sub w} is the area of a water cylinder that would absorb the same dose as the specified phantom. SPR and axial CT images were acquired using a dual-source CT scanner operated at 120 kV in single-source mode. To use the SPR image for estimating A{sub w},more » the pixel values of a SPR image were calibrated to physical water attenuation using a series of water phantoms. A{sub w} and the corresponding diameter D{sub w} were calculated using the derived attenuation-based methods (from either CT or SPR image). A{sub w} was also calculated using only geometrical dimensions of the phantoms (anterior-posterior and lateral dimensions or cross sectional area). Results: For abdomen phantoms, the geometry-based and attenuation-based methods gave similar results for D{sub w}. Using only geometric parameters, an overestimation of D{sub w} ranging from 4.3% to 21.5% was found for thorax phantoms. Results for D{sub w} using the CT image and SPR based methods agreed with each other within 4% on average in both thorax and abdomen phantoms. Conclusions: Either the cross sectional CT or SPR images can be used to estimate patient attenuation in CT. Both are more accurate than use of only geometrical information for the task of quantifying patient attenuation. The SPR based method requires calibration of SPR pixel values to physical water attenuation and this calibration would be best performed by the scanner manufacturer.« less

  9. Added value of SPECT/spiral CT versus SPECT or CT alone in diagnosing solitary skeletal lesions.

    PubMed

    Zhang, Yiqiu; Li, Beilei; Shi, Hongcheng; Yu, Haojun; Gu, Yushen; Xiu, Yan

    2017-08-14

    The aim of this study was to investigate the added value of SPECT/spiral CT versus SPECT or CT alone in the differential diagnosis of solitary skeletal lesions. This was a retrospective study on a total of 69 patients who had a solitary skeletal "hot spot" that could not be definitively diagnosed using planar scintigraphy. Thus, SPECT/spiral CT was performed on the indeterminate lesions. SPECT, CT and SPECT/spiral CT images were independently interpreted by two experienced doctors who have both identification of CT and nuclear medicine. Each lesion was graded on a 4-point diagnostic scale (1: benign, 2: likely benign, 3: likely malignant, 4: malignant). The final diagnosis of each lesion was based on pathological confirmation after surgery within 3 weeks of the bone scan. Final diagnoses based on the pathological results revealed that 43 of the 69 patients were diagnosed with malignancy, and the remaining 26 patients were diagnosed as having benign lesions. For SPECT and CT scans, both of the reviewers rated 55.1 % (38/69) and 37.7 % (26/69) of lesions as equivocal, with the help of SPECT/CT, 33.3 % (23/69) of lesions were rated as equivocal. The diagnostic accuracies of SPECT, CT alone and SPECT/CT were 66.7 % (46/69) ,82.6 % (57/69) and 85.5 %(59/69), respectively. The kappa scores for the degree of agreement between SPECT, CT alone or SPECT/CT with pathological results were 0.185 (p = 0.054) , 0.612 (p < 0.001) and 0.671 (p < 0.001), respectively. Compared with SPECT or imaging alone, SPECT/spiral CT imaging was more accurate and valuable in the differential diagnosis of solitary skeletal lesions and resulted in significantly fewer equivocal findings.

  10. Effects of microalloying on hot-rolled and cold-rolled Q&P steels

    NASA Astrophysics Data System (ADS)

    Azevedo de Araujo, Ana Luiza

    Third generation advanced high strength steels (AHSS) have been a major focus in steel development over the last decade. The premise of these types of steel is based on the potential to obtain excellent combinations of strength and ductility with low-alloy compositions by forming mixed microstructures containing retained austenite (RA). The development of heat treatments able to achieve the desired structures and properties, such as quenching and partitioning (Q&P) steels, is driven by new requirements to increase vehicle fuel economy by reducing overall weight while maintaining safety and crashworthiness. Microalloying additions of niobium (Nb) and vanadium (V) in sheet products are known to provide strengthening via grain refinement and precipitation hardening and may influence RA volume fraction and transformation behavior. Additions of microalloying elements in Q&P steels have not been extensively studied to date, however. The objective of the present study was to begin to understand the potential roles of Nb and V in hot-rolled and cold-rolled Q&P steel. For that, a common Q&P steel composition was selected as a Base alloy with 0.2C-1.5Si-2.0Mn (wt. %). Two alloys with an addition of Nb (0.02 and 0.04 wt. %) and one with an addition of V (0.06 wt. %) to the Base alloy were investigated. Both hot-rolled and cold-rolled/annealed Q&P simulations were conducted. In the hot-rolled Q&P study, thermomechanical processing was simulated via hot torsion testing in a GleebleRTM 3500, and four coiling temperatures (CT) were chosen. Microstructural evaluation (including RA measurements via electron backscattered diffraction - EBSD) and hardness measurements were performed for all alloys and coiling conditions. The analysis showed that Nb additions led to overall refinement of the prior microstructure. Maximum RA fractions were measured at the 375 °C CT, and microalloying was associated with increased RA in this condition when compared to the Base alloy. A change in austenite morphology from lath-like to blocky with increasing CT was observed. Hardness generally increased with decreasing CT, consistent with the increased fraction of harder phases in the microstructure. For the cold-rolled Q&P study, several combinations of quenching temperature (QT), partitioning temperature (PT), and partitioning time (t p) were examined using heat treatments in salt baths. Uniaxial tensile tests and RA measurements via x-ray diffraction (XRD) were performed for all alloys and heat treatment conditions. Scanning electron microscope (SEM) imaging and EBSD were conducted for a few select conditions. In terms of microstructure, Nb promoted an extensive refinement of the prior austenite grain size. Additions of V and Nb also seemed to affect the morphology of the microstructural constituents. It was observed that V generally increased austenite fractions at lower t p's, and the Nb-containing alloys had greater austenite fractions in most instances when compared to the Base alloy. Carbon content in austenite was usually increased or maintained with additions of Nb and V. In terms of mechanical properties, V slightly improved strength and elongation when compared to the Base alloy for most conditions. Niobium additions were somewhat more effective in improving ductility.

  11. 40 CFR 68.85 - Hot work permit.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 16 2012-07-01 2012-07-01 false Hot work permit. 68.85 Section 68.85... ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.85 Hot work permit. (a) The owner or operator shall issue a hot work permit for hot work operations conducted on or near a covered process. (b...

  12. 40 CFR 68.85 - Hot work permit.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Hot work permit. 68.85 Section 68.85... ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.85 Hot work permit. (a) The owner or operator shall issue a hot work permit for hot work operations conducted on or near a covered process. (b...

  13. 40 CFR 68.85 - Hot work permit.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 16 2013-07-01 2013-07-01 false Hot work permit. 68.85 Section 68.85... ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.85 Hot work permit. (a) The owner or operator shall issue a hot work permit for hot work operations conducted on or near a covered process. (b...

  14. 40 CFR 68.85 - Hot work permit.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Hot work permit. 68.85 Section 68.85... ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.85 Hot work permit. (a) The owner or operator shall issue a hot work permit for hot work operations conducted on or near a covered process. (b...

  15. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bieniosek, Matthew F.; Lee, Brian J.; Levin, Craig S., E-mail: cslevin@stanford.edu

    Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom withmore » sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed phantoms can be functionally equivalent to commercially available phantoms. They are a viable option for quickly distributing and fabricating low cost, customized phantoms.« less

  16. Novel Application of Micro-Computerized Tomography for Morphologic Characterization of the Murine Penis.

    PubMed

    O'Neill, Marisol; Huang, Gene O; Lamb, Dolores J

    2017-12-01

    The murine penis model has enriched our understanding of anomalous penile development. The morphologic characterization of the murine penis using conventional serial sectioning methods is labor intensive and prone to errors. To develop a novel application of micro-computerized tomography (micro-CT) with iodine staining for rapid, non-destructive morphologic study of murine penis structure. Penises were dissected from 10 adult wild-type mice and imaged using micro-CT with iodine staining. Images were acquired at 5-μm spatial resolution on a Bruker SkyScan 1272 micro-CT system. After images were acquired, the specimens were washed of any remaining iodine and embedded in paraffin for conventional histologic examination. Histologic and micro-CT measurements for all specimens were made by 2 independent observers. Measurements of penile structures were made on virtual micro-CT sections and histologic slides. The Lin concordance correlation coefficient demonstrated almost perfect strength of agreement for interobserver variability for histologic section (0.9995, 95% CI = 0.9990-0.9997) and micro-CT section (0.9982, 95% CI = 0.9963-0.9991) measurements. Bland-Altman analysis for agreement between the 2 modalities of measurement demonstrated mean differences of -0.029, 0.022, and -0.068 mm for male urogenital mating protuberance, baculum, and penile glans length, respectively. There did not appear to be a bias for overestimation or underestimation of measured lengths and limits of agreement were narrow. The enhanced ability offered by micro-CT to phenotype the murine penis has the potential to improve translational studies examining the molecular pathways contributing to anomalous penile development. The present study describes the first reported use of micro-CT with iodine staining for imaging the murine penis. Producing repeated histologic sections of identical orientation was limited by inherent imperfections in mounting and tissue sectioning, but this was compensated for by using micro-CT reconstructions to identify matching virtual sections. This study demonstrates the successful use of micro-CT with iodine staining, which has the potential for submicron spatial resolution, as a non-destructive method of characterizing murine penile morphology. O'Neill M, Huang GO, Lamb DJ. Novel Application of Micro-Computerized Tomography for Morphologic Characterization of the Murine Penis. J Sex Med 2017;14:1533-1539. Copyright © 2017. Published by Elsevier Inc.

  17. Volumetric applications for spiral CT in the thorax

    NASA Astrophysics Data System (ADS)

    Rubin, Geoffrey D.; Napel, Sandy; Leung, Ann N.

    1994-05-01

    Spiral computed tomography (CT) is a new technique for rapidly acquiring volumetric data within the body. By combining a continuous gantry rotation and table feed, it is possible to image the entire thorax within a single breath-hold. This eliminates the ventilatory misregistration seen with conventional thoracic CT, which can result in small pulmonary lesions being undetected. An additional advantage of a continuous data set is that axial sections can be reconstructed at arbitrary intervals along the spiral path, resulting in the generation of overlapping sections which diminish partial volume effects resulting from lesions that straddle adjacent sections. The rapid acquisition of spiral CT enables up to a 50% reduction in the total iodinated contrast dose required for routine thoracic CT scanning. This can be very important for imaging patients with cardiac and renal diseases and could reduce the cost of thoracic CT scanning. Alternatively, by combining a high flow peripheral intravenous iodinated contrast injection with a spiral CT acquisition, it is possible to obtain images of the vasculature, which demonstrate pulmonary arterial thrombi, aortic aneurysms and dissections, and congenital vascular anomalies in detail previously unattainable without direct arterial access.

  18. Composition and mechanism of anti-tumor effects of Hericium erinaceus mushroom extracts in tumor-bearing mice

    USDA-ARS?s Scientific Manuscript database

    We investigated anti-tumor effects of the following four extracts of freeze-dried Hericium erinaceus mushrooms in Balb/c mice intracutaneously transplanted on the backs with CT-26 colon cancer cells: HWE, hot-water extraction by boiling in water for 3 h; MWE, microwaving in 50% ethanol/water at 60 W...

  19. HEADSTONE OF MEDAL OF HONOR RECIPIENT CHARLES L. RUSSELL, SECTION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    HEADSTONE OF MEDAL OF HONOR RECIPIENT CHARLES L. RUSSELL, SECTION 3-E, GRAVE R1. VIEW TO NORTH. - Hot Springs National Cemetery, Virginia Medical Center 500 North Fifth Street, Hot Springs, Fall River County, SD

  20. 21 CFR 175.230 - Hot-melt strippable food coatings.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Hot-melt strippable food coatings. 175.230 Section... COATINGS Substances for Use as Components of Coatings § 175.230 Hot-melt strippable food coatings. Hot-melt..., white For use only as a component of hot-melt strippable food coatings applied to frozen meats and...

  1. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    PubMed

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  2. Comparison of eye lens dose on neuroimaging protocols between 16- and 64-section multidetector CT: achieving the lowest possible dose.

    PubMed

    Tan, J S P; Tan, K-L; Lee, J C L; Wan, C-M; Leong, J-L; Chan, L-L

    2009-02-01

    To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05. The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens. Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.

  3. 113. ARAI Hot cell (ARA626) Building wall sections and details ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    113. ARA-I Hot cell (ARA-626) Building wall sections and details of radio chemistry lab. Shows high-bay roof over hot cells and isolation rooms below grade storage pit for fuel elements. Norman Engineering Company: 961-area/SF-626-A-4. Date: January 1959. Ineel index code no. 068-0626-00-613-102724. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  4. SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, T; Hamacher, K

    2016-06-15

    Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET andmore » CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.« less

  5. 21 CFR 880.6085 - Hot/cold water bottle.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  6. 21 CFR 880.6085 - Hot/cold water bottle.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  7. 21 CFR 880.6085 - Hot/cold water bottle.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  8. 21 CFR 880.6085 - Hot/cold water bottle.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  9. 21 CFR 880.6085 - Hot/cold water bottle.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  10. 40 CFR 1066.965 - Hot soak test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Hot soak test. 1066.965 Section 1066.965 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... Procedures for Motor Vehicles § 1066.965 Hot soak test. Test vehicles for hot soak emissions as described in...

  11. 48 CFR 952.225-70 - Subcontracting for nuclear hot cell services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... hot cell services. 952.225-70 Section 952.225-70 Federal Acquisition Regulations System DEPARTMENT OF....225-70 Subcontracting for nuclear hot cell services. As prescribed in 925.7004, insert the following clause in solicitations and contracts: Subcontracting for Nuclear Hot Cell Services (MAR 1993) (a...

  12. Fast, Dense Low Cost Scintillator for Nuclear Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woody, Craig

    2009-07-31

    We have studied the morphology, transparency, and optical properties of SrHfO{sub 3}:Ce ceramics. Ceramics can be made transparent by carefully controlling the stoichiometry of the precursor powders. When fully dense, transparent samples can be obtained. Ceramics with a composition close to stoichiometry (Sr:Hf ~ 1) appear to show good transparency and a reasonable light yield several times that of BGO. The contact and distance transparency of ceramics hot-pressed at about 1450ºC is very good, but deteriorates at increasingly higher hot-press temperatures. If these ceramics can be produced in large quantities and sizes, at low cost, they may be of considerablemore » interest for PET and CT.« less

  13. What's Hot, What's Not: 2012

    ERIC Educational Resources Information Center

    Raths, David

    2012-01-01

    Like the Roman god Janus, whose twin faces look both forward and back, "Campus Technology" ("CT") is using the new year as an opportunity to reflect on some of the biggest IT trends and issues of 2011 and predict their fate in 2012. In the turbulent world of higher ed IT, this is no easy task--yesterday's news can easily become tomorrow's snooze.…

  14. CT scan (image)

    MedlinePlus

    CT stands for computerized tomography. In this procedure, a thin X-ray beam is rotated around the ... D image of a section through the body. CT scans are very detailed and provide excellent information ...

  15. Head CT (image)

    MedlinePlus

    CT stands for computerized tomography. In this procedure, a thin X-ray beam is rotated around the ... D image of a section through the body. CT scans are very detailed and provide excellent information ...

  16. ARCHITECTURAL WALL SECTIONS OF HOT PILOT PLANT (CPP640). INL DRAWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ARCHITECTURAL WALL SECTIONS OF HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111682. ALTERNATE ID NUMBER 8952-CPP-640-A-5. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  17. CT Scans

    MedlinePlus

    ... cross-sectional pictures of your body. Doctors use CT scans to look for Broken bones Cancers Blood clots Signs of heart disease Internal bleeding During a CT scan, you lie still on a table. The table ...

  18. Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis.

    PubMed

    Teymouri, Jessica; Hullar, Timothy E; Holden, Timothy A; Chole, Richard A

    2011-08-01

    To determine the efficacy of clinical computed tomographic (CT) imaging to verify postoperative electrode array placement in cochlear implant (CI) patients. Nine fresh cadaver heads underwent clinical CT scanning, followed by bilateral CI insertion and postoperative clinical CT scanning. Temporal bones were removed, trimmed, and scanned using micro-CT. Specimens were then dehydrated, embedded in either methyl methacrylate or LR White resin, and sectioned with a diamond wafering saw. Histology sections were examined by 3 blinded observers to determine the position of individual electrodes relative to soft tissue structures within the cochlea. Electrodes were judged to be within the scala tympani, scala vestibuli, or in an intermediate position between scalae. The position of the array could be estimated accurately from clinical CT scans in all specimens using micro-CT and histology as a criterion standard. Verification using micro-CT yielded 97% agreement, and histologic analysis revealed 95% agreement with clinical CT results. A composite, 3-dimensional image derived from a patient's preoperative and postoperative CT images using a clinical scanner accurately estimates the position of the electrode array as determined by micro-CT imaging and histologic analyses. Information obtained using the CT method provides valuable insight into numerous variables of interest to patient performance such as surgical technique, array design, and processor programming and troubleshooting.

  19. 40 CFR 86.138-96 - Hot soak test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Hot soak test. 86.138-96 Section 86...-Duty Vehicles; Test Procedures § 86.138-96 Hot soak test. (a)(1) Gasoline- and methanol-fueled vehicles. For gasoline- and methanol-fueled vehicles, the hot soak test shall be conducted immediately following...

  20. 40 CFR 86.1238-96 - Hot soak test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Hot soak test. 86.1238-96 Section 86... Methanol-Fueled Heavy-Duty Vehicles § 86.1238-96 Hot soak test. (a)(1) Gasoline- and methanol-fueled vehicles. For gasoline- and methanol-fueled vehicles, the hot soak test shall be conducted immediately...

  1. 40 CFR 86.138-96 - Hot soak test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Hot soak test. 86.138-96 Section 86...-Duty Vehicles; Test Procedures § 86.138-96 Hot soak test. (a)(1) Gasoline- and methanol-fueled vehicles. For gasoline- and methanol-fueled vehicles, the hot soak test shall be conducted immediately following...

  2. 40 CFR 86.1238-96 - Hot soak test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Hot soak test. 86.1238-96 Section 86... Methanol-Fueled Heavy-Duty Vehicles § 86.1238-96 Hot soak test. (a)(1) Gasoline- and methanol-fueled vehicles. For gasoline- and methanol-fueled vehicles, the hot soak test shall be conducted immediately...

  3. 40 CFR 86.138-96 - Hot soak test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Hot soak test. 86.138-96 Section 86...-Duty Vehicles; Test Procedures § 86.138-96 Hot soak test. (a)(1) Gasoline- and methanol-fueled vehicles. For gasoline- and methanol-fueled vehicles, the hot soak test shall be conducted immediately following...

  4. 40 CFR 86.1238-96 - Hot soak test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Hot soak test. 86.1238-96 Section 86... Methanol-Fueled Heavy-Duty Vehicles § 86.1238-96 Hot soak test. (a)(1) Gasoline- and methanol-fueled vehicles. For gasoline- and methanol-fueled vehicles, the hot soak test shall be conducted immediately...

  5. 40 CFR 86.138-96 - Hot soak test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Hot soak test. 86.138-96 Section 86...-Duty Vehicles; Test Procedures § 86.138-96 Hot soak test. (a)(1) Gasoline- and methanol-fueled vehicles. For gasoline- and methanol-fueled vehicles, the hot soak test shall be conducted immediately following...

  6. 40 CFR 86.138-96 - Hot soak test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Hot soak test. 86.138-96 Section 86...-Duty Vehicles; Test Procedures § 86.138-96 Hot soak test. (a)(1) Gasoline- and methanol-fueled vehicles. For gasoline- and methanol-fueled vehicles, the hot soak test shall be conducted immediately following...

  7. 40 CFR 86.1238-96 - Hot soak test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Hot soak test. 86.1238-96 Section 86... Methanol-Fueled Heavy-Duty Vehicles § 86.1238-96 Hot soak test. (a)(1) Gasoline- and methanol-fueled vehicles. For gasoline- and methanol-fueled vehicles, the hot soak test shall be conducted immediately...

  8. Spring 2014 Internship Diffuser Data Analysis

    NASA Technical Reports Server (NTRS)

    Laigaie, Robert T.; Ryan, Harry M.

    2014-01-01

    J-2X engine testing on the A-2 test stand at the NASA John C. Stennis Space Center (SSC) has recently concluded. As part of that test campaign, the engine was operated at lower power levels in support of expanding the use of J-2X to other missions. However, the A-2 diffuser was not designed for engine testing at the proposed low power levels. To evaluate the risk of damage to the diffuser, computer simulations were created of the rocket engine exhaust plume inside the 50ft long, water-cooled, altitude-simulating diffuser. The simulations predicted that low power level testing would cause the plume to oscillate in the lower sections of the diffuser. This can possibly cause excessive vibrations, stress, and heat transfer from the plume to the diffuser walls. To understand and assess the performance of the diffuser during low power level engine testing, nine accelerometers and four strain gages were installed around the outer surface of the diffuser. The added instrumentation also allowed for the verification of the rocket exhaust plume computational model. Prior to engine hot-fire testing, a diffuser water-flow test was conducted to verify the proper operation of the newly installed instrumentation. Subsequently, two J-2X engine hot-fire tests were completed. Hot-Fire Test 1 was 11.5 seconds in duration, and accelerometer and strain data verified that the rocket engine plume oscillated in the lower sections of the diffuser. The accelerometers showed very different results dependent upon location. The diffuser consists of four sections, with Section 1 being closest to the engine nozzle and Section 4 being farthest from the engine nozzle. Section 1 accelerometers showed increased amplitudes at startup and shutdown, but low amplitudes while the diffuser was started. Section 3 accelerometers showed the opposite results with near zero G amplitudes prior to and after diffuser start and peak amplitudes to +/- 100G while the diffuser was started. Hot-Fire Test 1 strain gages showed different data dependent on section. Section 1 strains were small, and were in the range of 50 to 150 microstrain, which would result in stresses from 1.45 to 4.35 ksi. The yield stress of the material, A-285 Grade C Steel, is 29.7 ksi. Section 4 strain gages showed much higher values with strains peaking at 1600 microstrain. This strain corresponds to a stress of 46.41 ksi, which is in excess of the yield stress, but below the ultimate stress of 55 to 75 ksi. The decreased accelerations and strain in Section 1, and the increased accelerations and strain in Sections 3 and 4 verified the computer simulation prediction of increased plume oscillations in the lower sections of the diffuser. Hot-Fire Test 2 ran for a duration of 125 seconds. The engine operated at a slightly higher power level than Hot-Fire Test 1 for the initial 35 seconds of the test. After 35 seconds the power level was lowered to Hot-Fire Test 1 levels. The acceleration and strain data for Hot-Fire Test 2 was similar during the initial part of the test. However, just prior to the engine being lowered to the Hot-Fire Test 1 power level, the strain gage data in Section 4 showed a large decrease to strains near zero microstrain from their peak at 1500 microstrain. Future work includes further strain and acceleration data analysis and evaluation.

  9. ARCHITECTURAL SECTIONS A, B, C, D, OF HOT PILOT PLANT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ARCHITECTURAL SECTIONS A, B, C, D, OF HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111681. ALTERNATE ID NUMBER 8952-CPP-640-A-5. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  10. Value of planar lymphoscintigraphy versus SPECT/CT in evaluation of sentinel lymph node in trunk melanoma - one center, large series, retrospective study.

    PubMed

    Benke, Małgorzata; Wocial, Krzysztof; Lewandowska, Weronika; Rutkowski, Piotr Łukasz; Teterycz, Paweł; Jarek, Piotr; Dedecjus, Marek

    2018-06-29

    Background Localization and histopathological examination of sentinel lymph node (SLN) is a standard of melanoma treatment. The first stage of identification of the SLN is the preoperative lymphoscintigraphy. The aim of this study was to assess and compare diagnostic value of planar lymphoscintigraphy (PL) and SPECT/CT in sentinel lymph node biopsy (SLNB) procedure performed in patients with cutaneous trunk melanoma. Material and Methods Between 2015 and 2016, patients with trunk melanoma (N=255, F/M 95/160), aged from 17 to 88 after an excisional biopsy, with primary tumor ≥ pT1b (AJCC 2009, median Breslow thickness 2.0± 3.13) were included in the study. In all the patients PL was followed by SPECT/CT 1-3 h after injection of 99mTc- colloid particles, and SLNB was performed the next day. Results SPECT-CT revealed 78 (18.6%) SLN more than PL, and in 40 patients showed additional lymph drainage regions leading to surgical adjustments. In 18 patients (7.1%) SPECT-CT revealed SLN not visible in the PL (false-negative PL) and in 22 patients (8.6%), foci of uptake interpreted in PL as hot SLNs were found to be non-nodal sites of uptake when assessed on SPECT/CT (false positive PL). SPECT-CT vs. PL mismatch was observed in 31 patients (12.2%) and was the most common in patients with primary lesions located in the anterior inferior medial region (75%). Conclusions Results of the presented study indicates the high diagnostic value of SPECT-CT in assessment of SLNs and proved that SPECT-CT increases the sensitivity and accuracy of SLN identification as compared to PL even in very experienced hands.

  11. Cross-sectional anatomy, computed tomography and magnetic resonance imaging of the head of common dolphin (Delphinus delphis) and striped dolphin (Stenella coeruleoalba).

    PubMed

    Alonso-Farré, J M; Gonzalo-Orden, M; Barreiro-Vázquez, J D; Barreiro-Lois, A; André, M; Morell, M; Llarena-Reino, M; Monreal-Pawlowsky, T; Degollada, E

    2015-02-01

    Computed tomography (CT) and low-field magnetic resonance imaging (MRI) were used to scan seven by-caught dolphin cadavers, belonging to two species: four common dolphins (Delphinus delphis) and three striped dolphins (Stenella coeruleoalba). CT and MRI were obtained with the animals in ventral recumbency. After the imaging procedures, six dolphins were frozen at -20°C and sliced in the same position they were examined. Not only CT and MRI scans, but also cross sections of the heads were obtained in three body planes: transverse (slices of 1 cm thickness) in three dolphins, sagittal (5 cm thickness) in two dolphins and dorsal (5 cm thickness) in two dolphins. Relevant anatomical structures were identified and labelled on each cross section, obtaining a comprehensive bi-dimensional topographical anatomy guide of the main features of the common and the striped dolphin head. Furthermore, the anatomical cross sections were compared with their corresponding CT and MRI images, allowing an imaging identification of most of the anatomical features. CT scans produced an excellent definition of the bony and air-filled structures, while MRI allowed us to successfully identify most of the soft tissue structures in the dolphin's head. This paper provides a detailed anatomical description of the head structures of common and striped dolphins and compares anatomical cross sections with CT and MRI scans, becoming a reference guide for the interpretation of imaging studies. © 2014 Blackwell Verlag GmbH.

  12. Filter paper-assisted cell transfer (FaCT) technique: A novel cell-sampling technique for intraoperative diagnosis of central nervous system tumors.

    PubMed

    Kawamura, Jumpei; Kamoshida, Shingo; Shimakata, Takaaki; Hayashi, Yurie; Sakamaki, Kuniko; Denda, Tamami; Kawai, Kenji; Kuwao, Sadahito

    2017-04-01

    Intraoperative diagnosis of central nervous system (CNS) tumors provides critical guidance to surgeons in the determination of surgical resection margins and treatment. The techniques and preparations used for the intraoperative diagnosis of CNS tumors include frozen sectioning and cytologic methods (squash smear and touch imprint). Cytologic specimens, which do not have freezing artifacts, are important as an adjuvant tool to frozen sections. However, if the amount of submitted tissue samples is limited, then it is difficult to prepare both frozen sections and squash smears or touch imprint specimens from a single sample at the same time. Therefore, the objective of this study was to derive cells directly from filter paper on which tumor samples are placed. The authors established the filter paper-assisted cell transfer (FaCT) smear technique, in which tumor cells are transferred onto a glass slide directly from the filter paper sample spot after the biopsy is removed. Cell yields and diagnostic accuracy of the FaCT smears were assessed in 40 CNS tumors. FaCT smears had ample cell numbers and well preserved cell morphology sufficient for cytologic diagnosis, even if the submitted tissues were minimal. The overall diagnostic concordance rates between frozen sections and FaCT smears were 90% and 87.5%, respectively (no significant differences). When combining FaCT smears with frozen sections, the diagnostic concordance rate rose to 92.5%. The current results suggest that the FaCT smear technique is a simple and effective processing method that has significant value for intraoperative diagnosis of CNS tumors. Cancer Cytopathol 2017;125:277-282. © 2016 American Cancer Society. © 2017 American Cancer Society.

  13. Single cross-sectional area of pectoralis muscle by computed tomography - correlation with bioelectrical impedance based skeletal muscle mass in healthy subjects.

    PubMed

    Kim, Young Saing; Kim, Eun Young; Kang, Shin Myung; Ahn, Hee Kyung; Kim, Hyung Sik

    2017-09-01

    Skeletal muscle depletion is an important prognostic factor in patients with chronic obstructive pulmonary disease (COPD); a recent study demonstrated significant correlations between pectoralis muscle area on an axial CT image and COPD-related traits. The purpose of this study was to evaluate the relation between pectoralis muscle areas on CT scans and total body skeletal muscle mass (SMM) in healthy subjects. For 434 subjects that underwent a low-dose chest CT and bioelectrical impedance analysis (BIA) during health screening from January to June of 2014, cross-sectional area of pectoralis muscles were measured in CT scans. Pearson's correlation and multiple linear regression analysis were used to assess the relationship between cross-sectional CT areas of pectoralis muscles and BIA-assessed SMMs. Mean age was 50 ± 10 years (78·8% were male). The mean cross-sectional area of pectoralis muscles was 24·1 cm 2  ± 6·8. A moderate correlation was observed between pectoralis muscle area and BIA-based SMM (r = 0·665, P<0.001). Multivariable analysis showed CT determined pectoralis muscle area was significantly associated with BIA-assessed SMM after adjusting for gender, weight, height and age (β = 0·14 ± 0·02, P<0·001). Cross-sectional area of the pectoralis muscles on single axial CT images shows moderate correlation with total body SMM determined by BIA in healthy subjects. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  14. Computer-assisted shape descriptors for skull morphology in craniosynostosis.

    PubMed

    Shim, Kyu Won; Lee, Min Jin; Lee, Myung Chul; Park, Eun Kyung; Kim, Dong Seok; Hong, Helen; Kim, Yong Oock

    2016-03-01

    Our aim was to develop a novel method for characterizing common skull deformities with high sensitivity and specificity, based on two-dimensional (2D) shape descriptors in computed tomography (CT) images. Between 2003 and 2014, 44 normal subjects and 39 infants with craniosynostosis (sagittal, 29; bicoronal, 10) enrolled for analysis. Mean age overall was 16 months (range, 1-120 months), with a male:female ratio of 56:29. Two reference planes, sagittal (S-plane: through top of lateral ventricle) and coronal (C-plane: at maximum dimension of fourth ventricle), were utilized to formulate three 2D shape descriptors (cranial index [CI], cranial radius index [CR], and cranial extreme spot index [CES]), which were then applied to S- and C-plane target images of both groups. In infants with sagittal craniosynostosis, CI in S-plane (S-CI) usually was <1.0 (mean, 0.78; range, 0.67-0.95), with CR consistently at 3 and a characteristic CES pattern of two discrete hot spots oriented diagonally. In the bicoronal craniosynostosis subset, CI was >1.0 (mean 1.11; range, 1.04-1.25), with CR at -3 and a CES pattern of four discrete diagonally oriented hot spots. Scatter plots underscored the highly intuitive joint performance of CI and CES in distinguishing normal and deformed states. Altogether, these novel 2D shape descriptors enabled effective discrimination of sagittal and bicoronal skull deformities. Newly developed 2D shape descriptors for cranial CT imaging enabled recognition of common skull deformities with statistical significance, perhaps providing impetus for automated CT-based diagnosis of craniosynostosis.

  15. Variation in the human ribs geometrical properties and mechanical response based on X-ray computed tomography images resolution.

    PubMed

    Perz, Rafał; Toczyski, Jacek; Subit, Damien

    2015-01-01

    Computational models of the human body are commonly used for injury prediction in automobile safety research. To create these models, the geometry of the human body is typically obtained from segmentation of medical images such as computed tomography (CT) images that have a resolution between 0.2 and 1mm/pixel. While the accuracy of the geometrical and structural information obtained from these images depend greatly on their resolution, the effect of image resolution on the estimation of the ribs geometrical properties has yet to be established. To do so, each of the thirty-four sections of ribs obtained from a Post Mortem Human Surrogate (PMHS) was imaged using three different CT modalities: standard clinical CT (clinCT), high resolution clinical CT (HRclinCT), and microCT. The images were processed to estimate the rib cross-section geometry and mechanical properties, and the results were compared to those obtained from the microCT images by computing the 'deviation factor', a metric that quantifies the relative difference between results obtained from clinCT and HRclinCT to those obtained from microCT. Overall, clinCT images gave a deviation greater than 100%, and were therefore deemed inadequate for the purpose of this study. HRclinCT overestimated the rib cross-sectional area by 7.6%, the moments of inertia by about 50%, and the cortical shell area by 40.2%, while underestimating the trabecular area by 14.7%. Next, a parametric analysis was performed to quantify how the variations in the estimate of the geometrical properties affected the rib predicted mechanical response under antero-posterior loading. A variation of up to 45% for the predicted peak force and up to 50% for the predicted stiffness was observed. These results provide a quantitative estimate of the sensitivity of the response of the FE model to the resolution of the images used to generate it. They also suggest that a correction factor could be derived from the comparison between microCT and HRclinCT images to improve the response of the model developed based on HRclinCT images. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Use of cooling air heat exchangers as replacements for hot section strategic materials

    NASA Technical Reports Server (NTRS)

    Gauntner, J. W.

    1983-01-01

    Because of financial and political constraints, strategic aerospace materials required for the hot section of future engines might be in short supply. As an alternative to these strategic materials, this study examines the use of a cooling air heat exchanger in combination with less advanced hot section materials. Cycle calculations are presented for future turbofan systems with overall pressure ratios to 65, bypass ratios near 13, and combustor exit temperatures to 3260 R. These calculations quantify the effect on TSFC of using a decreased materials technology in a turbofan system. The calculations show that the cooling air heat exchanger enables the feasibility of these engines.

  17. Turbine Engine Hot Section Technology 1986

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The Turbine Engine Hot Section Technology (HOST) Project of the NASA Lewis Research Center sponsored a workshop to discuss current research pertinent to turbine engine durability problems. Presentations were made concerning the hot section environment and the behavior of combustion liners, turbine blades, and turbine vanes. The presentations were divided into six sessions: Instrumentation, Combustion, Turbine Heat Transfer, Structural Analysis, Fatigue and Fracture, and Surface Protection. Topics discussed included modeling of thermal and fluid-flow phenomena, structural analysis, fatigue and fracture, surface protective coatings, constitutive behavior of materials, stress-strain response, and life-prediction methods. Researchers from industry, academia, and government presented results of their work sponsored by the HOST project.

  18. 3-D inelastic analysis methods for hot section components. Volume 2: Advanced special functions models

    NASA Technical Reports Server (NTRS)

    Wilson, R. B.; Banerjee, P. K.

    1987-01-01

    This Annual Status Report presents the results of work performed during the third year of the 3-D Inelastic Analysis Methods for Hot Sections Components program (NASA Contract NAS3-23697). The objective of the program is to produce a series of computer codes that permit more accurate and efficient three-dimensional analyses of selected hot section components, i.e., combustor liners, turbine blades, and turbine vanes. The computer codes embody a progression of mathematical models and are streamlined to take advantage of geometrical features, loading conditions, and forms of material response that distinguish each group of selected components.

  19. Hot section viewing system

    NASA Technical Reports Server (NTRS)

    Morey, W. W.

    1983-01-01

    The objective of the hot section viewing program is to develop a prototype optical system for viewing the interior of a gas turbine combustor during high temperature, high pressure operation in order to produce a visual record of some causes of premature hot section failures. The program began by identifying and analyzing system designs that would provide clearest images while being able to survive the hostile environment inside the combustion chamber. Different illumination methods and computer techniques for image enhancement and analysis were examined during a preliminary test phase. In the final phase of the program the prototype system was designed and fabricated and is currently being tested on a high pressure combustor rig.

  20. Accuracy of Rhenium-188 SPECT/CT activity quantification for applications in radionuclide therapy using clinical reconstruction methods.

    PubMed

    Esquinas, Pedro L; Uribe, Carlos F; Gonzalez, M; Rodríguez-Rodríguez, Cristina; Häfeli, Urs O; Celler, Anna

    2017-07-20

    The main applications of 188 Re in radionuclide therapies include trans-arterial liver radioembolization and palliation of painful bone-metastases. In order to optimize 188 Re therapies, the accurate determination of radiation dose delivered to tumors and organs at risk is required. Single photon emission computed tomography (SPECT) can be used to perform such dosimetry calculations. However, the accuracy of dosimetry estimates strongly depends on the accuracy of activity quantification in 188 Re images. In this study, we performed a series of phantom experiments aiming to investigate the accuracy of activity quantification for 188 Re SPECT using high-energy and medium-energy collimators. Objects of different shapes and sizes were scanned in Air, non-radioactive water (Cold-water) and water with activity (Hot-water). The ordered subset expectation maximization algorithm with clinically available corrections (CT-based attenuation, triple-energy window (TEW) scatter and resolution recovery was used). For high activities, the dead-time corrections were applied. The accuracy of activity quantification was evaluated using the ratio of the reconstructed activity in each object to this object's true activity. Each object's activity was determined with three segmentation methods: a 1% fixed threshold (for cold background), a 40% fixed threshold and a CT-based segmentation. Additionally, the activity recovered in the entire phantom, as well as the average activity concentration of the phantom background were compared to their true values. Finally, Monte-Carlo simulations of a commercial [Formula: see text]-camera were performed to investigate the accuracy of the TEW method. Good quantification accuracy (errors  <10%) was achieved for the entire phantom, the hot-background activity concentration and for objects in cold background segmented with a 1% threshold. However, the accuracy of activity quantification for objects segmented with 40% threshold or CT-based methods decreased (errors  >15%), mostly due to partial-volume effects. The Monte-Carlo simulations confirmed that TEW-scatter correction applied to 188 Re, although practical, yields only approximate estimates of the true scatter.

  1. Computer tomographic imaging and anatomic correlation of the human brain: A comparative atlas of thin CT-scan sections and correlated neuro-anatomic preparations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plets, C.; Baert, A.L.; Nijs, G.L.

    1986-01-01

    It is of the greatest importance to the radiologist, the neurologist and the neurosurgeon to be able to localize topographically a pathological brain process on the CT scan as precisely as possible. For that purpose, the identification of as many anatomical structures as possible on the CT scan image are necessary and indispensable. In this atlas a great number of detailed anatomical data on frontal horizontal CT scan sections, each being only 2 mm thick, are indicated, e.g. the cortical gyri, the basal ganglia, details of the white matter, extracranial muscles and blood vessels, parts of the base and themore » vault of the skull, etc. The very precise topographical description of the numerous CT scan images was realized by the author by confrontation of these images with the corresponding anatomical sections of the same brain specimen, performed by an original technique.« less

  2. A&M. TAN607. Shield wall sections and details around hot shop ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607. Shield wall sections and details around hot shop and special equipment room, showing taper, crane rail elevations, and elevation for biparting door (door no. 301) in wall between hot shop and special equipment room. Ralph M. Parsons 902-3-ANP-607-S 138. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-62-963-106782 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  3. 30 CFR 77.305 - Access to drying chambers, hot gas inlet chambers and ductwork; installation and maintenance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Access to drying chambers, hot gas inlet chambers and ductwork; installation and maintenance. 77.305 Section 77.305 Mineral Resources MINE SAFETY... drying chambers, hot gas inlet chambers and ductwork; installation and maintenance. Drying chambers, hot...

  4. 30 CFR 77.305 - Access to drying chambers, hot gas inlet chambers and ductwork; installation and maintenance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Access to drying chambers, hot gas inlet chambers and ductwork; installation and maintenance. 77.305 Section 77.305 Mineral Resources MINE SAFETY... drying chambers, hot gas inlet chambers and ductwork; installation and maintenance. Drying chambers, hot...

  5. 30 CFR 77.305 - Access to drying chambers, hot gas inlet chambers and ductwork; installation and maintenance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Access to drying chambers, hot gas inlet chambers and ductwork; installation and maintenance. 77.305 Section 77.305 Mineral Resources MINE SAFETY... drying chambers, hot gas inlet chambers and ductwork; installation and maintenance. Drying chambers, hot...

  6. 30 CFR 77.305 - Access to drying chambers, hot gas inlet chambers and ductwork; installation and maintenance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Access to drying chambers, hot gas inlet chambers and ductwork; installation and maintenance. 77.305 Section 77.305 Mineral Resources MINE SAFETY... drying chambers, hot gas inlet chambers and ductwork; installation and maintenance. Drying chambers, hot...

  7. 30 CFR 77.305 - Access to drying chambers, hot gas inlet chambers and ductwork; installation and maintenance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Access to drying chambers, hot gas inlet chambers and ductwork; installation and maintenance. 77.305 Section 77.305 Mineral Resources MINE SAFETY... drying chambers, hot gas inlet chambers and ductwork; installation and maintenance. Drying chambers, hot...

  8. Spatial clustering of high load ocular Chlamydia trachomatis infection in trachoma: a cross-sectional population-based study.

    PubMed

    Last, Anna; Burr, Sarah; Alexander, Neal; Harding-Esch, Emma; Roberts, Chrissy H; Nabicassa, Meno; Cassama, Eunice Teixeira da Silva; Mabey, David; Holland, Martin; Bailey, Robin

    2017-07-31

    Chlamydia trachomatis (Ct) is the most common cause of bacterial sexually transmitted infection and infectious cause of blindness (trachoma) worldwide. Understanding the spatial distribution of Ct infection may enable us to identify populations at risk and improve our understanding of Ct transmission. In this study, we sought to investigate the spatial distribution of Ct infection and the clinical features associated with high Ct load in trachoma-endemic communities on the Bijagós Archipelago (Guinea Bissau). We collected 1507 conjunctival samples and corresponding detailed clinical data during a cross-sectional population-based geospatially representative trachoma survey. We used droplet digital PCR to estimate Ct load on conjunctival swabs. Geostatistical tools were used to investigate clustering of ocular Ct infections. Spatial clusters (independent of age and gender) of individuals with high Ct loads were identified using local indicators of spatial association. We did not detect clustering of individuals with low load infections. These data suggest that infections with high bacterial load may be important in Ct transmission. These geospatial tools may be useful in the study of ocular Ct transmission dynamics and as part of trachoma surveillance post-treatment, to identify clusters of infection and thresholds of Ct load that may be important foci of re-emergent infection in communities. © FEMS 2017.

  9. Localized thin-section CT with radiomics feature extraction and machine learning to classify early-detected pulmonary nodules from lung cancer screening

    NASA Astrophysics Data System (ADS)

    Tu, Shu-Ju; Wang, Chih-Wei; Pan, Kuang-Tse; Wu, Yi-Cheng; Wu, Chen-Te

    2018-03-01

    Lung cancer screening aims to detect small pulmonary nodules and decrease the mortality rate of those affected. However, studies from large-scale clinical trials of lung cancer screening have shown that the false-positive rate is high and positive predictive value is low. To address these problems, a technical approach is greatly needed for accurate malignancy differentiation among these early-detected nodules. We studied the clinical feasibility of an additional protocol of localized thin-section CT for further assessment on recalled patients from lung cancer screening tests. Our approach of localized thin-section CT was integrated with radiomics features extraction and machine learning classification which was supervised by pathological diagnosis. Localized thin-section CT images of 122 nodules were retrospectively reviewed and 374 radiomics features were extracted. In this study, 48 nodules were benign and 74 malignant. There were nine patients with multiple nodules and four with synchronous multiple malignant nodules. Different machine learning classifiers with a stratified ten-fold cross-validation were used and repeated 100 times to evaluate classification accuracy. Of the image features extracted from the thin-section CT images, 238 (64%) were useful in differentiating between benign and malignant nodules. These useful features include CT density (p  =  0.002 518), sigma (p  =  0.002 781), uniformity (p  =  0.032 41), and entropy (p  =  0.006 685). The highest classification accuracy was 79% by the logistic classifier. The performance metrics of this logistic classification model was 0.80 for the positive predictive value, 0.36 for the false-positive rate, and 0.80 for the area under the receiver operating characteristic curve. Our approach of direct risk classification supervised by the pathological diagnosis with localized thin-section CT and radiomics feature extraction may support clinical physicians in determining truly malignant nodules and therefore reduce problems in lung cancer screening.

  10. Localized thin-section CT with radiomics feature extraction and machine learning to classify early-detected pulmonary nodules from lung cancer screening.

    PubMed

    Tu, Shu-Ju; Wang, Chih-Wei; Pan, Kuang-Tse; Wu, Yi-Cheng; Wu, Chen-Te

    2018-03-14

    Lung cancer screening aims to detect small pulmonary nodules and decrease the mortality rate of those affected. However, studies from large-scale clinical trials of lung cancer screening have shown that the false-positive rate is high and positive predictive value is low. To address these problems, a technical approach is greatly needed for accurate malignancy differentiation among these early-detected nodules. We studied the clinical feasibility of an additional protocol of localized thin-section CT for further assessment on recalled patients from lung cancer screening tests. Our approach of localized thin-section CT was integrated with radiomics features extraction and machine learning classification which was supervised by pathological diagnosis. Localized thin-section CT images of 122 nodules were retrospectively reviewed and 374 radiomics features were extracted. In this study, 48 nodules were benign and 74 malignant. There were nine patients with multiple nodules and four with synchronous multiple malignant nodules. Different machine learning classifiers with a stratified ten-fold cross-validation were used and repeated 100 times to evaluate classification accuracy. Of the image features extracted from the thin-section CT images, 238 (64%) were useful in differentiating between benign and malignant nodules. These useful features include CT density (p  =  0.002 518), sigma (p  =  0.002 781), uniformity (p  =  0.032 41), and entropy (p  =  0.006 685). The highest classification accuracy was 79% by the logistic classifier. The performance metrics of this logistic classification model was 0.80 for the positive predictive value, 0.36 for the false-positive rate, and 0.80 for the area under the receiver operating characteristic curve. Our approach of direct risk classification supervised by the pathological diagnosis with localized thin-section CT and radiomics feature extraction may support clinical physicians in determining truly malignant nodules and therefore reduce problems in lung cancer screening.

  11. U.S. EPA, Pesticide Product Label, COOKE SEVIN BRAND LIQUID CARBARYL INSECTICIDE, 07/10/1989

    EPA Pesticide Factsheets

    2011-04-14

    ... '('l~ i~'fdlU:tlOf: te. StJrfi(f~ ~~frf ~'~~~f spril~ rt£)d~fS ~~f CbJf(tIClni~!f. ~t hot kSf t~l! ~rodo(t JTI e,' en f:fctrHel f'Ql!J~Hf!t dCt: tv tt.E- pU:'~I~ilit,. ...

  12. 29 CFR 1926.51 - Sanitation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... requirements of this paragraph. (ii) Each lavatory shall be provided with hot and cold running water, or tepid...) through (v) of this section. (ii) One shower shall be provided for each 10 employees of each sex, or...) of this section. (iv) Showers shall be provided with hot and cold water feeding a common discharge...

  13. 29 CFR 1926.51 - Sanitation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... requirements of this paragraph. (ii) Each lavatory shall be provided with hot and cold running water, or tepid...) through (v) of this section. (ii) One shower shall be provided for each 10 employees of each sex, or...) of this section. (iv) Showers shall be provided with hot and cold water feeding a common discharge...

  14. Applying microCT and 3D visualization to Jurassic silicified conifer seed cones: A virtual advantage over thin-sectioning.

    PubMed

    Gee, Carole T

    2013-11-01

    As an alternative to conventional thin-sectioning, which destroys fossil material, high-resolution X-ray computed tomography (also called microtomography or microCT) integrated with scientific visualization, three-dimensional (3D) image segmentation, size analysis, and computer animation is explored as a nondestructive method of imaging the internal anatomy of 150-million-year-old conifer seed cones from the Late Jurassic Morrison Formation, USA, and of recent and other fossil cones. • MicroCT was carried out on cones using a General Electric phoenix v|tome|x s 240D, and resulting projections were processed with visualization software to produce image stacks of serial single sections for two-dimensional (2D) visualization, 3D segmented reconstructions with targeted structures in color, and computer animations. • If preserved in differing densities, microCT produced images of internal fossil tissues that showed important characters such as seed phyllotaxy or number of seeds per cone scale. Color segmentation of deeply embedded seeds highlighted the arrangement of seeds in spirals. MicroCT of recent cones was even more effective. • This is the first paper on microCT integrated with 3D segmentation and computer animation applied to silicified seed cones, which resulted in excellent 2D serial sections and segmented 3D reconstructions, revealing features requisite to cone identification and understanding of strobilus construction.

  15. Pressurized water nuclear reactor system with hot leg vortex mitigator

    DOEpatents

    Lau, Louis K. S.

    1990-01-01

    A pressurized water nuclear reactor system includes a vortex mitigator in the form of a cylindrical conduit between the hot leg conduit and a first section of residual heat removal conduit, which conduit leads to a pump and a second section of residual heat removal conduit leading back to the reactor pressure vessel. The cylindrical conduit is of such a size that where the hot leg has an inner diameter D.sub.1, the first section has an inner diameter D.sub.2, and the cylindrical conduit or step nozzle has a length L and an inner diameter of D.sub.3 ; D.sub.3 /D.sub.1 is at least 0.55, D.sub.2 is at least 1.9, and L/D.sub.3 is at least 1.44, whereby cavitation of the pump by a vortex formed in the hot leg is prevented.

  16. 1975 Memorial Award Paper. Image generation and display techniques for CT scan data. Thin transverse and reconstructed coronal and sagittal planes.

    PubMed

    Glenn, W V; Johnston, R J; Morton, P E; Dwyer, S J

    1975-01-01

    The various limitations to computerized axial tomographic (CT) interpretation are due in part to the 8-13 mm standard tissue plane thickness and in part to the absence of alternative planes of view, such as coronal or sagittal images. This paper describes a method for gathering multiple overlapped 8 mm transverse sections, subjecting these data to a deconvolution process, and then displaying thin (1 mm) transverse as well as reconstructed coronal and sagittal CT images. Verification of the deconvolution technique with phantom experiments is described. Application of the phantom results to human post mortem CT scan data illustrates this method's faithful reconstruction of coronal and sagittal tissue densities when correlated with actual specimen photographs of a sectioned brain. A special CT procedure, limited basal overlap scanning, is proposed for use on current first generation CT scanners without hardware modification.

  17. A&M. TAN607 sections. Section C cuts hot shop on its ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607 sections. Section C cuts hot shop on its 160-foot east/west line. Shows tapered shield wall on east and west facades of building. Relationship between hot shop and special equipment service room, cable tracks for overhead bridge crane, location of well. Concrete roof beams. Section D shows similar east/west of cold assembly room 115 and its bridge crane rail. Shows heavy shielding around special services cubicle and height of viewing windows on east and west sides. Rear of building is shown in relationship to the ridge east of the building. Referent drawing is ID-33-E-158 above. Ralph M. Parsons 902-3-ANP-607-A 106. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106758 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  18. [Effects of ingredients from Chinese herbs with nature of cold or hot on expression of TRPV1 and TRPM8].

    PubMed

    Sui, Feng; Yang, Na; Zhang, Changbin; Du, Xinliang; Li, Lanfang; Weng, Xiaogang; Guo, Shuying; Huo, Hairu; Jiang, Tingliang

    2010-06-01

    To study the effects of the ingredients from Chinese herbs with the nature of cold or hot on the expression of TRPV1 and TRPM8. The effects of ingredients from herbs on primary culture DRG neurons are observed in vitro. The expression quantity of gene is detected by the method of real time PCR. the 2 (-deltadeltaCT) method is applied to analyze the data. Ingredients from herbs with the nature of cold up-regulate the expression level of TRPV1 and down-regulate that of TRPM8, especially under the temperature condition of 39 degrees C; while ingredients from herbs with the nature of hot up-regulate the expression level of TRPM8 and down-regulated that of TRPV1, which is more significant under the temperature condition of 19 degrees C. The regulatory changes of TRPV1 and TRPM8 mRNA expression induced by the chemical ingredients might be related to the cold and hot natures of the herbs from which the ingredients are extracted. And this could be one of the therapeutic mechanisms for the treatment of Chinese herbal medicines to cold- and heat-related diseases.

  19. A Comparison between 3D Model Results Using Two Different Collision Schemes: Forward Scattering vs. Hard Sphere Collision

    NASA Astrophysics Data System (ADS)

    Lee, Y.; Combi, M. R.; Tenishev, V.; Bougher, S. W.; Johnson, R. E.; Tully, C.

    2016-12-01

    The recent observations of the Martian geomorphology suggest that water has played a critical role in forming the present status of the Martian atmosphere and environment. The inventory of water has been depleted throughout the planet's geologic time via various mechanisms from the surface to the uppermost atmosphere where the Sun-Mars interaction occurs. During the current epoch, dissociative recombination of O2+ is suggested as the main nonthermal mechanism that regulates the escape of atomic O, forming the hot O corona. A nascent hot O atom produced deep in the thermosphere undergoes collisions with the background thermal species, where the particle can lose energy and become thermalized before it reaches the collisionless regime and escape. The major hot O collisions with the background species that contribute to the thermalization of hot O are Ohot-Ocold, Ohot-CO2,cold, Ohot-COcold, and Ohot-N2,cold. In order to describe these collisions, there have been different collisions schemes used by the previous models. One of the most realistic descriptions involves using angular differential cross sections, and the simplest approach is using isotropic collision cross sections. Here, we present a comparison between the 3D model results using two different collision schemes to find equivalent hard sphere collision cross sections that satisfy the effects from using forward scattering cross sections. We adapted the newly calculated angular differential cross sections to the major hot O collisions. The hot O corona is simulated by coupling our Mars application of the 3D Adaptive Mesh Particle Simulator (M-AMPS) [Tenishev et al., 2008, 2013] and the Mars Global Ionosphere-Thermosphere Model (M-GITM) [Bougher et al., 2015].

  20. Use of cooling air heat exchangers as replacements for hot section strategic materials

    NASA Technical Reports Server (NTRS)

    Gauntner, J. W.

    1983-01-01

    Because of financial and political constraints, strategic aerospace materials required for the hot section of future engines might be in short supply. As an alternative to these strategic materials, this study examines the use of a cooling air heat exchanger in combination with less advanced hot section materials. Cycle calculations are presented for future turbofan systems with overall pressure ratios to 65, bypass ratios near 13, and combustor exit temperatures to 3260 R. These calculations quantify the effect on TSFC of using a decreased materials technology in a turbofan system. The calculations show that the cooling air heat exchanger enables the feasibility of these engines. Previously announced in STAR as N83-34946

  1. Land management effects on soil carbon in olive groves of Mediterranean areas

    NASA Astrophysics Data System (ADS)

    Fernández-Romero, Maria Luisa; Parras-Alcántara, Luis; Lozano-García, Beatriz; Clark, Joanna; Collins, Chris

    2015-04-01

    The study analysed soil organic carbon (SOC) and hot-water extractable carbon (HWC) in an agricultural Mediterranean area of Southern Spain under different land management: Conventional tillage (CT); Conventional tillage with the addition of oil mill waste, also known as alperujo (A); Conventional tillage with the addition of oil mill waste olive leaves (L); No tillage with chipped pruned branches (NT1); and No tillage with chipped pruned branches and weeds (NT2). SOC values in CT, A, NT1 and NT2 decreased with depth. In L, SOC also decreased with depth, although there was an increase of 89% from the first (0-10 cm) to the second horizon (10-16 cm). Total SOC stock (considering the entire soil profile) was very similar under A (101.9 Mg ha-1), CT (101.7 Mg ha-1), NT1 (105.8 Mg ha-1) and NT2 (111.3 Mg ha-1). However, SOC under L was significantly higher (p

  2. Photocarrier generation from interlayer charge-transfer transitions in WS2-graphene heterostructures

    PubMed Central

    Yuan, Long; Chung, Ting-Fung; Kuc, Agnieszka; Wan, Yan; Xu, Yang; Chen, Yong P.; Heine, Thomas; Huang, Libai

    2018-01-01

    Efficient interfacial carrier generation in van der Waals heterostructures is critical for their electronic and optoelectronic applications. We demonstrate broadband photocarrier generation in WS2-graphene heterostructures by imaging interlayer coupling–dependent charge generation using ultrafast transient absorption microscopy. Interlayer charge-transfer (CT) transitions and hot carrier injection from graphene allow carrier generation by excitation as low as 0.8 eV below the WS2 bandgap. The experimentally determined interlayer CT transition energies are consistent with those predicted from the first-principles band structure calculation. CT interactions also lead to additional carrier generation in the visible spectral range in the heterostructures compared to that in the single-layer WS2 alone. The lifetime of the charge-separated states is measured to be ~1 ps. These results suggest that interlayer interactions make graphene–two-dimensional semiconductor heterostructures very attractive for photovoltaic and photodetector applications because of the combined benefits of high carrier mobility and enhanced broadband photocarrier generation. PMID:29423439

  3. Nanoplasmonic biosensor: detection and amplification of dual bio-signatures of circulating tumor DNA.

    PubMed

    Nguyen, Anh H; Sim, Sang Jun

    2015-05-15

    Circulating tumor DNA (ctDNA) bearing tumor-specific mutation and methylation are promising biomarkers for noninvasive cancer assessment. However, existing methods for ctDNA detection are restricted to genetic mutations. Recently, nanoplasmonics has emerged as a platform for one-step dual detection with high sensitivity and specificity. Here we present a strategy for ultrasensitive detection of tumor-specific mutations (E542K and E545K) and methylation of ctDNA of PIK3CA gene based on localized surface plasmon resonance (LSPR) and the coupling plasmon mode of gold nanoparticles (AuNPs). Peptide nucleic acids (PNA) is used as a probe to capture and enrich the 69-bp PIK3CA ctDNA. The exposure of PNA-probed AuNPs to 200 fM ctDNA generates LSPR-peak shift of 4.3 nm, corresponding to the primary response. Immunogold colloids are exploited as methylation detectors and plasmon coupling based enhancement for secondary response. LSPR-peak shifted from 4.3 nm to 11.4 nm upon the immunogold colloids binding to two methylcytosines (mCpG), which is an approximately 107% increase, compared to that of the primary response. This enhancement leads to four times (~50 fM) improvement of sensitivity and because of two mCpG sites, ctDNA was detected. These results demonstrate that the sensor can simultaneously detect the hot-spot mutation and epigenetic changes on the ctDNA. Promisingly, other specific-tumor mutants and epigenetic changes can be detected at low concentration with this platform. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Medical Emergency Team Tutored Learning Environment

    DTIC Science & Technology

    2008-05-01

    of clickable hot- spot regions. The right half displays a detailed image, depending on what region of the overall patient view was most recently...oriented items such as “ Blood samples before antibiotics” or “CT before lumbar puncture.” Within the bounds of the identified area of performance...gram positive infection at a sterile site ( blood culture, Cerebrospinal Fluid (CSF) culture, blood gram stain, CSF gram stain, and pleural tap gram

  5. A novel hot-melt extrusion formulation of albendazole for increasing dissolution properties.

    PubMed

    Martinez-Marcos, Laura; Lamprou, Dimitrios A; McBurney, Roy T; Halbert, Gavin W

    2016-02-29

    The main aim of the research focused on the production of hot-melt extrusion (HME) formulations with increased dissolution properties of albendazole (ABZ). Therefore, HME was applied as a continuous manufacturing technique to produce amorphous solid dispersions of the poorly water soluble drug ABZ combined with the polymer matrix polyvinylpyrrolidone PVP K12. HME formulations of ABZ-PVP K12 comprised a drug content of 1%, 5% and 10% w/w. The main analytical characterisation techniques used were scanning electron microscopy (SEM), micro-computed tomography (μ-CT), X-ray powder diffraction (XRPD), differential scanning calorimetry (DSC) and dissolution profile studies. The application of SEM, XRPD and DSC evidenced drug physical transformation from crystalline to amorphous state and therefore, the achievement of an amorphous solid dispersion. The introduction of a novel technique, μ-CT, to characterise the internal structure of these materials revealed key information regarding materials distribution and void content. Dissolution profile studies evidenced a high increase in drug release profile compared to pure ABZ. These promising results can lead to a great enhancement of the oral bioavailability of ABZ dosage forms. Therefore, HME is a potential continuous manufacturing technique to overcome ABZ poor solubility properties and lead to a significant increase in the therapeutic effect. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Simulation studies promote technological development of radiofrequency phased array hyperthermia.

    PubMed

    Wust, P; Seebass, M; Nadobny, J; Deuflhard, P; Mönich, G; Felix, R

    1996-01-01

    A treatment planning program package for radiofrequency hyperthermia has been developed. It consists of software modules for processing three-dimensional computerized tomography (CT) data sets, manual segmentation, generation of tetrahedral grids, numerical calculation and optimisation of three-dimensional E field distributions using a volume surface integral equation algorithm as well as temperature distributions using an adaptive multilevel finite-elements code, and graphical tools for simultaneous representation of CT data and simulation results. Heat treatments are limited by hot spots in healthy tissues caused by E field maxima at electrical interfaces (bone/muscle). In order to reduce or avoid hot spots suitable objective functions are derived from power deposition patterns and temperature distributions, and are utilised to optimise antenna parameters (phases, amplitudes). The simulation and optimisation tools have been applied to estimate the improvements that could be reached by upgrades of the clinically used SIGMA-60 applicator (consisting of a single ring of four antenna pairs). The investigated upgrades are increased number of antennas and channels (triple-ring of 3 x 8 antennas and variation of antenna inclination. Significant improvement of index temperatures (1-2 degrees C) is achieved by upgrading the single ring to a triple ring with free phase selection for every antenna or antenna pair. Antenna amplitudes and inclinations proved as less important parameters.

  7. 40 CFR 420.70 - Applicability; description of the hot forming subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Applicability; description of the hot forming subcategory. 420.70 Section 420.70 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY Hot Forming...

  8. 40 CFR 93.116 - Criteria and procedures: Localized CO, PM10, and PM2.5 violations (hot-spots).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., PM10, and PM2.5 violations (hot-spots). 93.116 Section 93.116 Protection of Environment ENVIRONMENTAL....116 Criteria and procedures: Localized CO, PM10, and PM2.5 violations (hot-spots). (a) This paragraph... hot-spot analysis in PM10 and PM2.5 nonattainment and maintenance areas for FHWA/FTA projects that are...

  9. 40 CFR 93.116 - Criteria and procedures: Localized CO, PM10, and PM2.5 violations (hot-spots).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., PM10, and PM2.5 violations (hot-spots). 93.116 Section 93.116 Protection of Environment ENVIRONMENTAL....116 Criteria and procedures: Localized CO, PM10, and PM2.5 violations (hot-spots). (a) This paragraph... hot-spot analysis in PM10 and PM2.5 nonattainment and maintenance areas for FHWA/FTA projects that are...

  10. 40 CFR 93.116 - Criteria and procedures: Localized CO, PM10, and PM2.5 violations (hot-spots).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., PM10, and PM2.5 violations (hot-spots). 93.116 Section 93.116 Protection of Environment ENVIRONMENTAL....116 Criteria and procedures: Localized CO, PM10, and PM2.5 violations (hot-spots). (a) This paragraph... hot-spot analysis in PM10 and PM2.5 nonattainment and maintenance areas for FHWA/FTA projects that are...

  11. 40 CFR 93.116 - Criteria and procedures: Localized CO, PM10, and PM2.5 violations (hot-spots).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., PM10, and PM2.5 violations (hot-spots). 93.116 Section 93.116 Protection of Environment ENVIRONMENTAL....116 Criteria and procedures: Localized CO, PM10, and PM2.5 violations (hot-spots). (a) This paragraph... hot-spot analysis in PM10 and PM2.5 nonattainment and maintenance areas for FHWA/FTA projects that are...

  12. 40 CFR 93.116 - Criteria and procedures: Localized CO, PM10, and PM2.5 violations (hot-spots).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., PM10, and PM2.5 violations (hot-spots). 93.116 Section 93.116 Protection of Environment ENVIRONMENTAL....116 Criteria and procedures: Localized CO, PM10, and PM2.5 violations (hot-spots). (a) This paragraph... hot-spot analysis in PM10 and PM2.5 nonattainment and maintenance areas for FHWA/FTA projects that are...

  13. The effects of composition and thermal path on hot ductility of forging steels

    NASA Astrophysics Data System (ADS)

    Connolly, Brendan M.

    This work examines the effects of composition and thermal path on the hot ductility of several forging steels with varied aluminum and nitrogen content. The primary mechanisms and controlling factors related to hot ductility are identified with a focus on the role of precipitates and segregation. The unique thermal paths and solidification structures of large cross-section forging ingots are discussed. Hot ductility testing is performed in a manner that approximates industrial conditions experienced by large cross-section forging ingots. A computer model for precipitation of aluminum nitride and vanadium nitride in austenite is presented. Industrial material is examined for comparison to experimental findings. It is found that increased aluminum and nitrogen content coarsens the as-solidified structure. The combined effects of microsegregation and uphill diffusion during deformation allow for carbide precipitation at prior austenite grain boundaries which reduces the hot ductility.

  14. Comparative evaluation of in-house manual, and commercial semi-automated and automated DNA extraction platforms in the sample preparation of human stool specimens for a Salmonella enterica 5'-nuclease assay.

    PubMed

    Schuurman, Tim; de Boer, Richard; Patty, Rachèl; Kooistra-Smid, Mirjam; van Zwet, Anton

    2007-12-01

    In the present study, three methods (NucliSens miniMAG [bioMérieux], MagNA Pure DNA Isolation Kit III Bacteria/Fungi [Roche], and a silica-guanidiniumthiocyanate {Si-GuSCN-F} procedure for extracting DNA from stool specimens were compared with regard to analytical performance (relative DNA recovery and down stream real-time PCR amplification of Salmonella enterica DNA), stability of the extracted DNA, hands-on time (HOT), total processing time (TPT), and costs. The Si-GuSCN-F procedure showed the highest analytical performance (relative recovery of 99%, S. enterica real-time PCR sensitivity of 91%) at the lowest associated costs per extraction (euro 4.28). However, this method did required the longest HOT (144 min) and subsequent TPT (176 min) when processing 24 extractions. Both miniMAG and MagNA Pure extraction showed similar performances at first (relative recoveries of 57% and 52%, S. enterica real-time PCR sensitivity of 85%). However, when difference in the observed Ct values after real-time PCR were taken into account, MagNA Pure resulted in a significant increase in Ct value compared to both miniMAG and Si-GuSCN-F (with on average +1.26 and +1.43 cycles). With regard to inhibition all methods showed relatively low inhibition rates (< 4%), with miniMAG providing the lowest rate (0.7%). Extracted DNA was stable for at least 1 year for all methods. HOT was lowest for MagNA Pure (60 min) and TPT was shortest for miniMAG (121 min). Costs, finally, were euro 4.28 for Si-GuSCN, euro 6.69 for MagNA Pure and euro 9.57 for miniMAG.

  15. Innovation and fusion of x-ray and optical tomography for mouse studies of breast cancer

    NASA Astrophysics Data System (ADS)

    Wang, Ge; Cong, Wenxiang; Yang, Qingsong; Pian, Qi; Zhu, Shouping; Liang, Jimin; Barroso, Margarida; Intes, Xavier

    2016-10-01

    For early detection and targeted therapy, receptor expression profiling is instrumental to classifying breast cancer into sub-groups. In particular, human epidermal growth factor receptor 2 (HER2) expression has been shown to have both prognostic and predictive values. Recently, an increasingly more complex view of HER2 in breast cancer has emerged from genome sequencing that highlights the role of inter- and intra-tumor heterogeneity in therapy resistance. Studies on such heterogeneity demand high-content, high-resolution functional and molecular imaging in vivo, which cannot be achieved using any single imaging tool. Clearly, there is a critical need to develop a multimodality approach for breast cancer imaging. Since 2006, grating-based x-ray imaging has been developed for much-improved x-ray images. In 2014, the demonstration of fluorescence molecular tomography (FMT) guided by x-ray grating-based micro-CT was reported with encouraging results and major drawbacks. In this paper, we propose to integrate grating-based x-ray tomography (GXT) and high-dimensional optical tomography (HOT) into the first-of-its-kind truly-fused GXT-HOT (pronounced as "Get Hot") system for imaging of breast tumor heterogeneity, HER2 expression and dimerization, and therapeutic response. The primary innovation lies in developing a brand-new high-content, high-throughput x-ray optical imager based on several contemporary techniques to have MRI-type soft tissue contrast, PET-like sensitivity and specificity, and micro-CT-equivalent resolution. This system consists of two orthogonal x-ray Talbot-Lau interferometric imaging chains and a hyperspectral time-resolved single-pixel optical imager. Both the system design and pilot results will be reported in this paper, along with relevant issues under further investigation.

  16. Applying microCT and 3D visualization to Jurassic silicified conifer seed cones: A virtual advantage over thin-sectioning1

    PubMed Central

    Gee, Carole T.

    2013-01-01

    • Premise of the study: As an alternative to conventional thin-sectioning, which destroys fossil material, high-resolution X-ray computed tomography (also called microtomography or microCT) integrated with scientific visualization, three-dimensional (3D) image segmentation, size analysis, and computer animation is explored as a nondestructive method of imaging the internal anatomy of 150-million-year-old conifer seed cones from the Late Jurassic Morrison Formation, USA, and of recent and other fossil cones. • Methods: MicroCT was carried out on cones using a General Electric phoenix v|tome|x s 240D, and resulting projections were processed with visualization software to produce image stacks of serial single sections for two-dimensional (2D) visualization, 3D segmented reconstructions with targeted structures in color, and computer animations. • Results: If preserved in differing densities, microCT produced images of internal fossil tissues that showed important characters such as seed phyllotaxy or number of seeds per cone scale. Color segmentation of deeply embedded seeds highlighted the arrangement of seeds in spirals. MicroCT of recent cones was even more effective. • Conclusions: This is the first paper on microCT integrated with 3D segmentation and computer animation applied to silicified seed cones, which resulted in excellent 2D serial sections and segmented 3D reconstructions, revealing features requisite to cone identification and understanding of strobilus construction. PMID:25202495

  17. Development of lung cancer CT screening operating support system

    NASA Astrophysics Data System (ADS)

    Ishigaki, Rikuta; Hanai, Kozou; Suzuki, Masahiro; Kawata, Yoshiki; Niki, Noboru; Eguchi, Kenji; Kakinuma, Ryutaro; Moriyama, Noriyuki

    2009-02-01

    In Japan, lung cancer death ranks first among men and third among women. Lung cancer death is increasing yearly, thus early detection and treatment are needed. For this reason, CT screening for lung cancer has been introduced. The CT screening services are roughly divided into three sections: office, radiology and diagnosis sections. These operations have been performed through paper-based or a combination of paper-based and an existing electronic health recording system. This paper describes an operating support system for lung cancer CT screening in order to make the screening services efficient. This operating support system is developed on the basis of 1) analysis of operating processes, 2) digitalization of operating information, and 3) visualization of operating information. The utilization of the system is evaluated through an actual application and users' survey questionnaire obtained from CT screening centers.

  18. 40 CFR 406.80 - Applicability; description of the hot cereal subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Applicability; description of the hot cereal subcategory. 406.80 Section 406.80 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GRAIN MILLS POINT SOURCE CATEGORY Hot Cereal Subcategory § 406...

  19. 46 CFR 177.970 - Protection against hot piping.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Protection against hot piping. 177.970 Section 177.970 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.970 Protection against hot piping. Piping...

  20. 46 CFR 177.970 - Protection against hot piping.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Protection against hot piping. 177.970 Section 177.970 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.970 Protection against hot piping. Piping...

  1. 46 CFR 116.970 - Protection against hot piping.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Protection against hot piping. 116.970 Section 116.970 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... ARRANGEMENT Rails and Guards § 116.970 Protection against hot piping. Piping, including valves, pipe fittings...

  2. 46 CFR 116.970 - Protection against hot piping.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Protection against hot piping. 116.970 Section 116.970 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... ARRANGEMENT Rails and Guards § 116.970 Protection against hot piping. Piping, including valves, pipe fittings...

  3. 46 CFR 177.970 - Protection against hot piping.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Protection against hot piping. 177.970 Section 177.970 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.970 Protection against hot piping. Piping...

  4. 46 CFR 177.970 - Protection against hot piping.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Protection against hot piping. 177.970 Section 177.970 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.970 Protection against hot piping. Piping...

  5. 46 CFR 116.970 - Protection against hot piping.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Protection against hot piping. 116.970 Section 116.970 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... ARRANGEMENT Rails and Guards § 116.970 Protection against hot piping. Piping, including valves, pipe fittings...

  6. 46 CFR 116.970 - Protection against hot piping.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Protection against hot piping. 116.970 Section 116.970 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... ARRANGEMENT Rails and Guards § 116.970 Protection against hot piping. Piping, including valves, pipe fittings...

  7. 46 CFR 116.970 - Protection against hot piping.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Protection against hot piping. 116.970 Section 116.970 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... ARRANGEMENT Rails and Guards § 116.970 Protection against hot piping. Piping, including valves, pipe fittings...

  8. 46 CFR 177.970 - Protection against hot piping.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Protection against hot piping. 177.970 Section 177.970 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.970 Protection against hot piping. Piping...

  9. A&M. TAN607 sections. Section A shows variable roof lines, variable ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607 sections. Section A shows variable roof lines, variable thickness of hot shop shield walls, relationship of subterranean pool to grade. Section B shows relative heights of hot shop floor and its control gallery, position of bridge cranes and manipulator rails. Locomotive service pit. Referent drawing is ID-33-E-158 Above. Ralph M. Parsons 902-3-ANP-607-A 105. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106757 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  10. Turbine Engine Hot Section Technology (HOST)

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Research and plans concerning aircraft gas turbine engine hot section durability problems were discussed. Under the topics of structural analysis, fatigue and fracture, surface protective coatings, combustion, turbine heat transfer, and instrumentation specific points addressed were the thermal and fluid environment around liners, blades, and vanes, material coatings, constitutive behavior, stress-strain response, and life prediction methods for the three components.

  11. On 3-D inelastic analysis methods for hot section components. Volume 1: Special finite element models

    NASA Technical Reports Server (NTRS)

    Nakazawa, S.

    1988-01-01

    This annual status report presents the results of work performed during the fourth year of the 3-D Inelastic Analysis Methods for Hot Section Components program (NASA Contract NAS3-23697). The objective of the program is to produce a series of new computer codes permitting more accurate and efficient 3-D analysis of selected hot section components, i.e., combustor liners, turbine blades and turbine vanes. The computer codes embody a progression of math models and are streamlined to take advantage of geometrical features, loading conditions, and forms of material response that distinguish each group of selected components. Volume 1 of this report discusses the special finite element models developed during the fourth year of the contract.

  12. 76 FR 401 - MetLife Insurance Company of Connecticut, et al.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-04

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. IC-29544; File No. 812-13816] MetLife Insurance... Section 17(b) of the Act from Section 17(a) of the Act. Applicants: MetLife Insurance Company of Connecticut (``MetLife of CT''), MetLife of CT Separate Account Eleven for Variable Annuities (``Separate...

  13. 75 FR 16205 - MetLife Insurance Company of Connecticut, et al.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-31

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. IC-29190; File No. 812-13700] MetLife Insurance... Section 17(b) of the Act from Section 17(a) of the Act. Applicants: MetLife Insurance Company of Connecticut (``MetLife of CT''), MetLife of CT Separate Account Eleven for Variable Annuities (``Separate...

  14. 21 CFR 1020.33 - Computed tomography (CT) equipment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... opening where insertion of any part of the human body into the primary beam is possible. (2) For systems... Section 1020.33 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... diameters of 32.0 centimeters for testing any CT system designed to image any section of the body (whole...

  15. 21 CFR 1020.33 - Computed tomography (CT) equipment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... opening where insertion of any part of the human body into the primary beam is possible. (2) For systems... Section 1020.33 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... diameters of 32.0 centimeters for testing any CT system designed to image any section of the body (whole...

  16. Measurements in an axisymmetric turbulent wake with rotation downstream of a model wind turbine

    NASA Astrophysics Data System (ADS)

    Dufresne, Nathaniel; Wosnik, Martin

    2012-11-01

    Energy production data from several of the existing offshore wind farms indicate that turbine arrays may enter a stall condition which can cause an overall energy production shortfall (which can exceed 10%). This deep array stall is (presumably) due to the wakes generated by turbines upstream interacting with turbine rotors downstream. It is hypothesized that there is a critical array spacing at which this stall occurs, but that this spacing is dependent on rotor thrust cT (which is determined by tip-speed ratio λ and power coefficient cP of the rotor), Reynolds number, upstream conditions, and possibly wall roughness. An experimental investigation of the axial and azimuthal velocity field measurements in the wake of a single 3-bladed wind turbine with rotor diameter of 0.91m was conducted. The turbine was positioned in the free stream, near the entrance of the 6m × 2.5m test section of the UNH FPF, which can achieve test section velocities of up to 15 m/s and Reynolds numbers δ+ = δuτ / ν ~ 30 , 000 . Hot-wire anemometry was used to obtain velocity field measurements. The data obtained will be used to examine similarity scaling functions for velocity, wake growth, and turbulence derived from an equilibrium similarity analysis of the far wake.

  17. Intravenous volume tomographic pulmonary angiography imaging

    NASA Astrophysics Data System (ADS)

    Ning, Ruola; Strang, John G.; Chen, Biao; Conover, David L.; Yu, Rongfeng

    1999-05-01

    This study presents a new intravenous (IV) tomographic angiography imaging technique, called intravenous volume tomographic digital angiography (VTDA) for cross sectional pulmonary angiography. While the advantages of IV-VTDA over spiral CT in terms of volume scanning time and resolution have been validated and reported in our previous papers for head and neck vascular imaging, the superiority of IV-VTDA over spiral CT for cross sectional pulmonary angiography has not been explored yet. The purpose of this study is to demonstrate the advantage of isotropic resolution of IV-VTDA in the x, y and z directions through phantom and animal studies, and to explore its clinical application for detecting clots in pulmonary angiography. A prototype image intensifier-based VTDA imaging system has been designed and constructed by modifying a GE 8800 CT scanner. This system was used for a series of phantom and dog studies. A pulmonary vascular phantom was designed and constructed. The phantom was scanned using the prototype VTDA system for direct 3D reconstruction. Then the same phantom was scanned using a GE CT/i spiral CT scanner using the routine pulmonary CT angiography protocols. IV contrast injection and volume scanning protocols were developed during the dog studies. Both VTDA reconstructed images and spiral CT images of the specially designed phantom were analyzed and compared. The detectability of simulated vessels and clots was assessed as the function of iodine concentration levels, oriented angles, and diameters of the vessels and clots. A set of 3D VTDA reconstruction images of dog pulmonary arteries was obtained with different IV injection rates and isotropic resolution in the x, y and z directions. The results of clot detection studies in dog pulmonary arteries have also been shown. This study presents a new tomographic IV angiography imaging technique for cross sectional pulmonary angiography. The results of phantom and animal studies indicate that IV-VTDA is superior to spiral CT for cross sectional pulmonary angiography.

  18. Absolute Integral Cross Sections for the State-selected Ion-Molecule Reaction N2+(X2Σg+ v+ = 0-2) + C2H2 in the Collision Energy Range of 0.03-10.00 eV

    NASA Astrophysics Data System (ADS)

    Xu, Yuntao; Xiong, Bo; Chung Chang, Yih; Ng, C. Y.

    2016-08-01

    Using the vacuum ultraviolet laser pulsed field ionization-photoion source, together with the double-quadrupole-double-octopole mass spectrometer developed in our laboratory, we have investigated the state-selected ion-molecule reaction {{{{N}}}2}+({X}2{{{{Σ }}}{{g}}}+; v + = 0-2, N+ = 0-9) + C2H2, achieving high internal-state selectivity and high kinetic energy resolution for reactant {{{{N}}}2}+ ions. The charge transfer (CT) and hydrogen-atom transfer (HT) channels, which lead to the respective formation of product {{{C}}}2{{{{H}}}2}+ and N2H+ ions, are observed. The vibrationally selected absolute integral cross sections for the CT [σ CT(v +)] and HT [[σ HT(v +)] channels obtained in the center-of-mass collision energy (E cm) range of 0.03-10.00 eV reveal opposite E cm dependences. The σ CT(v +) is found to increase as E cm is decreased, and is consistent with the long-range exothermic CT mechanism, whereas the E cm enhancement observed for the σ HT(v +) suggests effective coupling of kinetic energy to internal energy, enhancing the formation of N2H+. The σ HT(v +) curve exhibits a step at E cm = 0.70-1.00 eV, suggesting the involvement of the excited {{{C}}}2{{{{H}}}2}+({A}2{{{{Σ }}}{{g}}}+) state in the HT reaction. Contrary to the strong E cm dependences for σ CT(v +) and σ HT(v +), the effect of vibrational excitation of {{{{N}}}2}+ on both the CT and HT channels is marginal. The branching ratios and cross sections for the CT and HT channels determined in the present study are useful for modeling the atmospheric compositions of Saturn's largest moon, Titan. These cross sections and branching ratios are also valuable for benchmarking theoretical calculations on chemical dynamics of the titled reaction.

  19. 3D temporal subtraction on multislice CT images using nonlinear warping technique

    NASA Astrophysics Data System (ADS)

    Ishida, Takayuki; Katsuragawa, Shigehiko; Kawashita, Ikuo; Kim, Hyounseop; Itai, Yoshinori; Awai, Kazuo; Li, Qiang; Doi, Kunio

    2007-03-01

    The detection of very subtle lesions and/or lesions overlapped with vessels on CT images is a time consuming and difficult task for radiologists. In this study, we have developed a 3D temporal subtraction method to enhance interval changes between previous and current multislice CT images based on a nonlinear image warping technique. Our method provides a subtraction CT image which is obtained by subtraction of a previous CT image from a current CT image. Reduction of misregistration artifacts is important in the temporal subtraction method. Therefore, our computerized method includes global and local image matching techniques for accurate registration of current and previous CT images. For global image matching, we selected the corresponding previous section image for each current section image by using 2D cross-correlation between a blurred low-resolution current CT image and a blurred previous CT image. For local image matching, we applied the 3D template matching technique with translation and rotation of volumes of interests (VOIs) which were selected in the current and the previous CT images. The local shift vector for each VOI pair was determined when the cross-correlation value became the maximum in the 3D template matching. The local shift vectors at all voxels were determined by interpolation of shift vectors of VOIs, and then the previous CT image was nonlinearly warped according to the shift vector for each voxel. Finally, the warped previous CT image was subtracted from the current CT image. The 3D temporal subtraction method was applied to 19 clinical cases. The normal background structures such as vessels, ribs, and heart were removed without large misregistration artifacts. Thus, interval changes due to lung diseases were clearly enhanced as white shadows on subtraction CT images.

  20. Application of continuous-wave terahertz computed tomography for the analysis of chicken bone structure

    NASA Astrophysics Data System (ADS)

    Li, Bin; Wang, Dayong; Rong, Lu; Zhai, Changchao; Wang, Yunxin; Zhao, Jie

    2018-02-01

    Terahertz (THz) radiation is able to penetrate many different types of nonpolar and nonmetallic materials without the damaging effects of x-rays. THz technology can be combined with computed tomography (CT) to form THz CT, which is an effective imaging method that is used to visualize the internal structure of a three-dimensional sample as cross-sectional images. Here, we reported an application of THz as the radiation source in CT imaging by replacing the x-rays. In this method, the sample cross section is scanned in all translation and rotation directions. Then, the projection data are reconstructed using a tomographic reconstruction algorithm. Two-dimensional (2-D) cross-sectional images of the chicken ulna were obtained through the continuous-wave (CW) THz CT system. Given by the difference of the THz absorption of different substances, the compact bone and spongy bone inside the chicken ulna are structurally distinguishable in the 2-D cross-sectional images. Using the filtered back projection algorithm, we reconstructed the projection data of the chicken ulna at different projection angle intervals and found that the artifacts and noise in the images are strikingly increased when the projection angle intervals become larger, reflected by the blurred boundary of the compact bone. The quality and fidelity of the 2-D cross-sectional images could be substantially improved by reducing the projection angle intervals. Our experimental data demonstrated a feasible application of the CW THz CT system in biological imaging.

  1. Micro-computed Tomography versus the Cross-sectioning Method to Evaluate Dentin Defects Induced by Different Mechanized Instrumentation Techniques.

    PubMed

    Stringheta, Carolina Pessoa; Pelegrine, Rina Andréa; Kato, Augusto Shoji; Freire, Laila Gonzales; Iglecias, Elaine Faga; Gavini, Giulio; Bueno, Carlos Eduardo da Silveira

    2017-12-01

    The objective of this study was to compare the methods of micro-computed tomography (micro-CT) and cross-sectioning followed by stereomicroscopy in assessing dentinal defects after instrumentation with different mechanized systems. Forty mesial roots of mandibular molars were scanned and divided into 4 groups (n = 10): Group R, Reciproc; Group PTN, ProTaper Next; Group WOG, WaveOne Gold; Group PDL, ProDesign Logic. After instrumentation, the roots were once again submitted to a micro-CT scan, and then sectioned at 3, 6, and 9 mm from the apex, and assessed for the presence of complete and incomplete dentinal defects under a stereomicroscope. The nonparametric Kruskal-Wallis, Friedman, and Wilcoxon tests were used in the statistical analysis. The study used a significance level of 5%. The total number of defects observed by cross-sectioning followed by stereomicroscopy was significantly higher than that observed by micro-CT, in all of the experimental groups (P ≤ .05). All of the defects identified in the postoperative period were already present in the corresponding preoperative period. There was no significant difference among the instrumentation systems as to the median numbers of defects, for either cross-sectioning followed by stereomicroscopy or micro-CT, at all the root levels (P > .05). In the micro-CT analysis, no significant difference was found between the median numbers of pre- and postinstrumentation defects, regardless of the instrumentation system (P > .05). None of the evaluated instrumentation systems led to the formation of new dentin defects. All of the defects identified in the stereomicroscopic analysis were already present before instrumentation, or were absent at both time points in the micro-CT analysis, indicating that the formation of new defects resulted from the sectioning procedure performed before stereomicroscopy and not from instrumentation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. [Hot topics of circulating tumor DNA testing in breast cancer].

    PubMed

    Liu, Y H; Zhou, B; Xu, L; Xin, L

    2017-02-01

    The progress of gene detection technologies represented by next generation sequencing (NGS) and digital PCR laid a foundation for studies of circulating tumor DNA (ctDNA) in breast cancer. In 2014, the NGS workgroup organized by the College of American Pathologists (CAP) published the College of American Pathologists ' Laboratory Standards for Next - Generation Sequencing Clinical Tests, which provides a blueprint for the standardization of gene testing. In 2015, the Guidelines for Diagnostic Next - generation Sequencing published by the European Society of Human Genetics claimed that NGS is unacceptable in clinical practice before studies guided by guidelines are approved. Although existing studies show the benefits of ctDNA testing in disease monitoring and prognosis analyzing, we have a ways to go to normalize the procedure and build strict detection criteria.

  3. 46 CFR 115.710 - Inspection and testing prior to hot work.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Inspection and testing prior to hot work. 115.710 Section 115.710 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS... AND CERTIFICATION Repairs and Alterations § 115.710 Inspection and testing prior to hot work. (a) An...

  4. 46 CFR 176.710 - Inspection and testing prior to hot work.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Inspection and testing prior to hot work. 176.710 Section 176.710 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS... testing prior to hot work. (a) An inspection for flammable or combustible gases must be conducted by a...

  5. 46 CFR 176.710 - Inspection and testing prior to hot work.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Inspection and testing prior to hot work. 176.710 Section 176.710 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS... testing prior to hot work. (a) An inspection for flammable or combustible gases must be conducted by a...

  6. 46 CFR 115.710 - Inspection and testing prior to hot work.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Inspection and testing prior to hot work. 115.710 Section 115.710 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS... AND CERTIFICATION Repairs and Alterations § 115.710 Inspection and testing prior to hot work. (a) An...

  7. 46 CFR 176.710 - Inspection and testing prior to hot work.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Inspection and testing prior to hot work. 176.710 Section 176.710 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS... testing prior to hot work. (a) An inspection for flammable or combustible gases must be conducted by a...

  8. 46 CFR 115.710 - Inspection and testing prior to hot work.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Inspection and testing prior to hot work. 115.710 Section 115.710 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS... AND CERTIFICATION Repairs and Alterations § 115.710 Inspection and testing prior to hot work. (a) An...

  9. 46 CFR 176.710 - Inspection and testing prior to hot work.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Inspection and testing prior to hot work. 176.710 Section 176.710 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS... testing prior to hot work. (a) An inspection for flammable or combustible gases must be conducted by a...

  10. 46 CFR 115.710 - Inspection and testing prior to hot work.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Inspection and testing prior to hot work. 115.710 Section 115.710 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS... AND CERTIFICATION Repairs and Alterations § 115.710 Inspection and testing prior to hot work. (a) An...

  11. 76 FR 35400 - Continuation of Suspended Antidumping Duty Investigation on Certain Hot-Rolled Flat-Rolled Carbon...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-17

    ... Russian Federation (``Russia'') would likely lead to continuation or recurrence of dumping, and material... duty investigation on hot- rolled steel from Russia (``the Agreement''), pursuant to section 751(c) of... the suspended antidumping duty investigation on hot- rolled steel from Russia would likely lead to a...

  12. 36 CFR 7.18 - Hot Springs National Park.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Hot Springs National Park. 7.18 Section 7.18 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.18 Hot Springs National Park. (a) Commercial...

  13. 36 CFR 7.18 - Hot Springs National Park.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Hot Springs National Park. 7.18 Section 7.18 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.18 Hot Springs National Park. (a) Commercial...

  14. 36 CFR 7.18 - Hot Springs National Park.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false Hot Springs National Park. 7.18 Section 7.18 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.18 Hot Springs National Park. (a) Commercial...

  15. 36 CFR 7.18 - Hot Springs National Park.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 1 2014-07-01 2014-07-01 false Hot Springs National Park. 7.18 Section 7.18 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.18 Hot Springs National Park. (a) Commercial...

  16. 36 CFR 7.18 - Hot Springs National Park.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 1 2013-07-01 2013-07-01 false Hot Springs National Park. 7.18 Section 7.18 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.18 Hot Springs National Park. (a) Commercial...

  17. 21 CFR 890.5710 - Hot or cold disposable pack.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hot or cold disposable pack. 890.5710 Section 890.5710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5710 Hot or cold...

  18. 21 CFR 890.5710 - Hot or cold disposable pack.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hot or cold disposable pack. 890.5710 Section 890.5710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5710 Hot or cold...

  19. 21 CFR 890.5710 - Hot or cold disposable pack.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hot or cold disposable pack. 890.5710 Section 890.5710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5710 Hot or cold...

  20. 21 CFR 890.5710 - Hot or cold disposable pack.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hot or cold disposable pack. 890.5710 Section 890.5710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5710 Hot or cold...

  1. 21 CFR 890.5710 - Hot or cold disposable pack.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hot or cold disposable pack. 890.5710 Section 890.5710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5710 Hot or cold...

  2. 48 CFR 925.7003 - Requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... FOREIGN ACQUISITION Acquisition of Nuclear Hot Cell Services 925.7003 Requirements. (a) For the acquisition of nuclear hot cell services under the conditions in paragraph (b) of this section, the selection...

  3. 48 CFR 925.7003 - Requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... FOREIGN ACQUISITION Acquisition of Nuclear Hot Cell Services 925.7003 Requirements. (a) For the acquisition of nuclear hot cell services under the conditions in paragraph (b) of this section, the selection...

  4. 48 CFR 925.7003 - Requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... FOREIGN ACQUISITION Acquisition of Nuclear Hot Cell Services 925.7003 Requirements. (a) For the acquisition of nuclear hot cell services under the conditions in paragraph (b) of this section, the selection...

  5. 48 CFR 925.7003 - Requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... FOREIGN ACQUISITION Acquisition of Nuclear Hot Cell Services 925.7003 Requirements. (a) For the acquisition of nuclear hot cell services under the conditions in paragraph (b) of this section, the selection...

  6. 48 CFR 925.7003 - Requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... FOREIGN ACQUISITION Acquisition of Nuclear Hot Cell Services 925.7003 Requirements. (a) For the acquisition of nuclear hot cell services under the conditions in paragraph (b) of this section, the selection...

  7. Contingency power for small turboshaft engines using water injection into turbine cooling air

    NASA Technical Reports Server (NTRS)

    Biesiadny, Thomas J.; Klann, Gary A.; Clark, David A.; Berger, Brett

    1987-01-01

    Because of one engine inoperative requirements, together with hot-gas reingestion and hot day, high altitude takeoff situations, power augmentation for multiengine rotorcraft has always been of critical interest. However, power augmentation using overtemperature at the turbine inlet will shorten turbine life unless a method of limiting thermal and mechanical stresses is found. A possible solution involves allowing the turbine inlet temperature to rise to augment power while injecting water into the turbine cooling air to limit hot-section metal temperatures. An experimental water injection device was installed in an engine and successfully tested. Although concern for unprotected subcomponents in the engine hot section prevented demonstration of the technique's maximum potential, it was still possible to demonstrate increases in power while maintaining nearly constant turbine rotor blade temperature.

  8. MicroPET/CT Colonoscopy in long-lived Min mouse using NM404

    NASA Astrophysics Data System (ADS)

    Christensen, Matthew B.; Halberg, Richard B.; Schutten, Melissa M.; Weichert, Jamey P.

    2009-02-01

    Colon cancer is a leading cause of death in the US, even though many cases are preventable if tumors are detected early. One technique to promote screening is Computed Tomography Colonography (CTC). NM404 is a second generation phospholipid ether analogue which has demonstrated selective uptake and prolonged retention in 43/43 types of malignant tumors but not inflammatory sites or premalignant lesions. The purpose of this experiment was to evaluate (SWR x B6 )F1.Min mice as a preclinical model to test MicroPET/CT dual modality virtual colonoscopy. Each animal was given an IV injection of 124I-NM404 (100 uCi) 24, 48 and 96 hours prior to scanning on a dedicated microPET/CT system. Forty million counts were histogrammed in 3D and reconstructed using an OSEM 2D algorithm. Immediately after PET acquisition, a 93 m volumetric CT was acquired at 80 kVp, 800 uA and 350 ms exposures. Following CT, the mouse was sacrificed. The entire intestinal tract was excised, washed, insufflated, and scanned ex vivo A total of eight tissue samples from the small intestine were harvested: 5 were benign adenomas, 2 were malignant adenocarcinomas, and 1 was a Peyer's patch (lymph tissue) . The sites of these samples were positioned on CT and PET images based on morphological cues and the distance from the anus. Only 1/8 samples showed tracer uptake. several hot spots in the microPET image were not chosen for histology. (SWR x B6)F1.Min mice develop benign and malignant tumors, making this animal model a strong candidate for future dual modality microPET/CT virtual colonography studies.

  9. 40 CFR 93.109 - Criteria and procedures for determining conformity of transportation plans, programs, and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... NAAQS. Paragraph (d) of this section explains when a hot-spot test is required. Paragraph (e) of this... insignificant motor vehicle emissions. Paragraph (g) of this section addresses isolated rural nonattainment and....5 hot-spots. § 93.117 PM10 and PM2.5 control measures Project (Not From a Conforming Plan and TIP...

  10. 40 CFR 93.109 - Criteria and procedures for determining conformity of transportation plans, programs, and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... NAAQS. Paragraph (d) of this section explains when a hot-spot test is required. Paragraph (e) of this... insignificant motor vehicle emissions. Paragraph (g) of this section addresses isolated rural nonattainment and....5 hot-spots. § 93.117 PM10 and PM2.5 control measures Project (Not From a Conforming Plan and TIP...

  11. 40 CFR 93.109 - Criteria and procedures for determining conformity of transportation plans, programs, and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... NAAQS. Paragraph (d) of this section explains when a hot-spot test is required. Paragraph (e) of this... insignificant motor vehicle emissions. Paragraph (g) of this section addresses isolated rural nonattainment and....5 hot-spots. § 93.117 PM10 and PM2.5 control measures Project (Not From a Conforming Plan and TIP...

  12. Sensitivity of hot-cathode ionization vacuum gages in several gases

    NASA Technical Reports Server (NTRS)

    Holanda, R.

    1972-01-01

    Four hot-cathode ionization vacuum gages were calibrated in 12 gases. The relative sensitivities of these gages were compared to several gas properties. Ionization cross section was the physical property which correlated best with gage sensitivity. The effects of gage accelerating voltage and ionization-cross-section energy level were analyzed. Recommendations for predicting gage sensitivity according to gage type were made.

  13. HOT CELL BUILDING, TRA632. FIRST FLOOR FOUNDATION PLAN SHOWS SECTIONALIZED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    HOT CELL BUILDING, TRA-632. FIRST FLOOR FOUNDATION PLAN SHOWS SECTIONALIZED FLOOR LOADINGS AND CONCRETE SLAB THICKNESSES, A TYPICAL FEATURE OF NUCLEAR ARCHITECTURE. IDAHO OPERATIONS OFFICE MTR-632-IDO-2, 11/1952. INL INDEX NO. 531-0632-62-396-110561, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  14. Creep fatigue life prediction for engine hot section materials (isotropic)

    NASA Technical Reports Server (NTRS)

    Moreno, V.

    1983-01-01

    The Hot Section Technology (HOST) program, creep fatigue life prediction for engine hot section materials (isotropic), is reviewed. The program is aimed at improving the high temperature crack initiation life prediction technology for gas turbine hot section components. Significant results include: (1) cast B1900 and wrought IN 718 selected as the base and alternative materials respectively; (2) fatigue test specimens indicated that measurable surface cracks appear early in the specimen lives, i.e., 15% of total life at 871 C and 50% of life at 538 c; (3) observed crack initiation sites are all surface initiated and are associated with either grain boundary carbides or local porosity, transgrannular cracking is observed at the initiation site for all conditions tested; and (4) an initial evaluation of two life prediction models, representative of macroscopic (Coffin-Mason) and more microscopic (damage rate) approaches, was conducted using limited data generated at 871 C and 538 C. It is found that the microscopic approach provides a more accurate regression of the data used to determine crack initiation model constants, but overpredicts the effect of strain rate on crack initiation life for the conditions tested.

  15. Computed tomography and cross-sectional anatomy of the metatarsus and digits of the one-humped camel (Camelus dromedarius) and buffalo ( Bos bubalis).

    PubMed

    El-Shafey, A; Kassab, A

    2013-04-01

    The purpose of the present study was to provide a detailed computed tomography (CT) and cross-sectional anatomic reference of the normal metatarsus and digits for the camel and buffalo, as well as to compare between metatarsus and digits in these animals to outstand a basis for diagnosis of their diseases. Advantages, including depiction of detailed cross-sectional anatomy, improved contrast resolution and computer reformatting, make it a potentially valuable diagnostic technique. The hind limbs of 12 healthy adult camel and buffalo were used. Clinically relevant anatomic structures were identified and labelled at each level in the corresponding images (CT and anatomic slices). CT images were used to identify the bony and soft tissue structures of the metatarsus and digits. The knowledge of normal anatomy of the camel and buffalo metatarsus and digits would serve as initial reference to the evaluation of CT images in these species. © 2012 Blackwell Verlag GmbH.

  16. Computed tomographic anatomy of the heads of blue-and-gold macaws (Ara ararauna), African grey parrots (Psittacus erithacus), and monk parakeets (Myiopsitta monachus).

    PubMed

    Veladiano, Irene A; Banzato, Tommaso; Bellini, Luca; Montani, Alessandro; Catania, Salvatore; Zotti, Alessandro

    2016-12-01

    OBJECTIVE To create an atlas of the normal CT anatomy of the head of blue-and-gold macaws (Ara ararauna), African grey parrots (Psittacus erithacus), and monk parakeets (Myiopsitta monachus). ANIMALS 3 blue-and-gold macaws, 5 African grey parrots, and 6 monk parakeets and cadavers of 4 adult blue-and-gold macaws, 4 adult African grey parrots, and 7 monk parakeets. PROCEDURES Contrast-enhanced CT imaging of the head of the live birds was performed with a 4-multidetector-row CT scanner. Cadaveric specimens were stored at -20°C until completely frozen, and each head was then sliced at 5-mm intervals to create reference cross sections. Frozen cross sections were cleaned with water and photographed on both sides. Anatomic structures within each head were identified with the aid of the available literature, labeled first on anatomic photographs, and then matched to and labeled on corresponding CT images. The best CT reconstruction filter, window width, and window level for obtaining diagnostic images of each structure were also identified. RESULTS Most of the clinically relevant structures of the head were identified in both the cross-sectional photographs and corresponding CT images. Optimal visibility of the bony structures was achieved via CT with a standard soft tissue filter and pulmonary window. The use of contrast medium allowed a thorough evaluation of the soft tissues. CONCLUSIONS AND CLINICAL RELEVANCE The labeled CT images and photographs of anatomic structures of the heads of common pet parrot species created in this study may be useful as an atlas to aid interpretation of images obtained with any imaging modality.

  17. 75 FR 75455 - Certain Hot-Rolled Flat-Rolled Carbon-Quality Steel Products From Brazil: Final Results of Full...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-03

    ...-Rolled Carbon-Quality Steel Products From Brazil: Final Results of Full Sunset Review of Countervailing... of the countervailing duty (CVD) order on certain hot-rolled flat-rolled carbon-quality steel products (hot-rolled steel) from Brazil, pursuant to section 751(c) of the Tariff Act of 1930, as amended...

  18. Dependent lung opacity at thin-section CT: evaluation by spirometrically-gated CT of the influence of lung volume.

    PubMed

    Lee, Ki Nam; Yoon, Seong Kuk; Sohn, Choon Hee; Choi, Pil Jo; Webb, W Richard

    2002-01-01

    To evaluate the influence of lung volume on dependent lung opacity seen at thin-section CT. In thirteen healthy volunteers, thin-section CT scans were performed at three levels (upper, mid, and lower portion of the lung) and at different lung volumes (10, 30, 50, and 100% vital capacity), using spirometric gated CT. Using a three-point scale, two radiologists determined whether dependent opacity was present, and estimated its degree. Regional lung attenuation at a level 2 cm above the diaphragm was determined using semiautomatic segmentation, and the diameter of a branch of the right lower posterior basal segmental artery was measured at each different vital capacity. At all three anatomic levels, dependent opacity occurred significantly more often at lower vital capacities (10, 30%) than at 100% vital capacity (p = 0.001). Visually estimated dependent opacity was significantly related to regional lung attenuation (p < 0.0001), which in dependent areas progressively increased as vital capacity decreased (p < 0.0001). The presence of dependent opacity and regional lung attenuation of a dependent area correlated significantly with increased diameter of a segmental arterial branch (r = 0.493 and p = 0.0002; r = 0.486 and p = 0.0003, respectively). Visual estimation and CT measurements of dependent opacity obtained by semiautomatic segmentation are significantly influenced by lung volume and are related to vascular diameter.

  19. Nano-Computed Tomography: Technique and Applications.

    PubMed

    Kampschulte, M; Langheinirch, A C; Sender, J; Litzlbauer, H D; Althöhn, U; Schwab, J D; Alejandre-Lafont, E; Martels, G; Krombach, G A

    2016-02-01

    Nano-computed tomography (nano-CT) is an emerging, high-resolution cross-sectional imaging technique and represents a technical advancement of the established micro-CT technology. Based on the application of a transmission target X-ray tube, the focal spot size can be decreased down to diameters less than 400 nanometers (nm). Together with specific detectors and examination protocols, a superior spatial resolution up to 400 nm (10 % MTF) can be achieved, thereby exceeding the resolution capacity of typical micro-CT systems. The technical concept of nano-CT imaging as well as the basics of specimen preparation are demonstrated exemplarily. Characteristics of atherosclerotic plaques (intraplaque hemorrhage and calcifications) in a murine model of atherosclerosis (ApoE (-/-)/LDLR(-/-) double knockout mouse) are demonstrated in the context of superior spatial resolution in comparison to micro-CT. Furthermore, this article presents the application of nano-CT for imaging cerebral microcirculation (murine), lung structures (porcine), and trabecular microstructure (ovine) in contrast to micro-CT imaging. This review shows the potential of nano-CT as a radiological method in biomedical basic research and discusses the application of experimental, high resolution CT techniques in consideration of other high resolution cross-sectional imaging techniques. Nano-computed tomography is a high resolution CT-technology for 3D imaging at sub-micrometer resolution. The technical concept bases on a further development of the established ex-vivo-micro-CT technology. By improvement of the spatial resolution, structures at a cellular level become visible (e.g. osteocyte lacunae). © Georg Thieme Verlag KG Stuttgart · New York.

  20. 3D intrathoracic region definition and its application to PET-CT analysis

    NASA Astrophysics Data System (ADS)

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.

    2014-03-01

    Recently developed integrated PET-CT scanners give co-registered multimodal data sets that offer complementary three-dimensional (3D) digital images of the chest. PET (positron emission tomography) imaging gives highly specific functional information of suspect cancer sites, while CT (X-ray computed tomography) gives associated anatomical detail. Because the 3D CT and PET scans generally span the body from the eyes to the knees, accurate definition of the intrathoracic region is vital for focusing attention to the central-chest region. In this way, diagnostically important regions of interest (ROIs), such as central-chest lymph nodes and cancer nodules, can be more efficiently isolated. We propose a method for automatic segmentation of the intrathoracic region from a given co-registered 3D PET-CT study. Using the 3D CT scan as input, the method begins by finding an initial intrathoracic region boundary for a given 2D CT section. Next, active contour analysis, driven by a cost function depending on local image gradient, gradient-direction, and contour shape features, iteratively estimates the contours spanning the intrathoracic region on neighboring 2D CT sections. This process continues until the complete region is defined. We next present an interactive system that employs the segmentation method for focused 3D PET-CT chest image analysis. A validation study over a series of PET-CT studies reveals that the segmentation method gives a Dice index accuracy of less than 98%. In addition, further results demonstrate the utility of the method for focused 3D PET-CT chest image analysis, ROI definition, and visualization.

  1. A&M. TAN633. Hot cell floor plans, elevations, sections. Hole schedule ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-633. Hot cell floor plans, elevations, sections. Hole schedule (penetrations through concrete). Swing-door details. Ralph M. Parsons 1229-13-ANP/GE-3-633-A-3. Date: December 1956. Approved by INEEL Classification Office for public release. INNEL index code no. 034-0633-00-693-107317 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  2. 115. ARAI Details of hot cell section of building ARA626. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    115. ARA-I Details of hot cell section of building ARA-626. Shows location of high density concrete, viewing windows, filters, monorail crane, bridge crane, and other details. Norman Engineering Company 961-area/SF-626-MS-1. Date: January 1959. Ineel index code no. 068-0626-40-613-102737. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  3. 10 CFR 431.102 - Definitions concerning commercial water heaters, hot water supply boilers, and unfired hot water...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... section 340 of the Act, 42 U.S.C. 6311. ASTM-D-2156-80 means the test standard published in 1980 by the... that is industrial equipment, including products meeting this description that are designed to heat... sections and does not include a boiler that is custom designed and field constructed. If the boiler is...

  4. Engine Development Design Margins Briefing Charts

    NASA Technical Reports Server (NTRS)

    Bentz, Chuck

    2006-01-01

    New engines experience durability problems after entering service. The most prevalent and costly is the hot section, particularly the high-pressure turbine. The origin of durability problems can be traced back to: 1) the basic aero-mechanical design systems, assumptions, and design margins used by the engine designers, 2) the available materials systems, and 3) to a large extent, aggressive marketing in a highly competitive environment that pushes engine components beyond the demonstrated capability of the basic technology available for the hardware designs. Unfortunately the user must operate the engine in the service environment in order to learn the actual thrust loading and the time at max effort take-off conditions used in service are needed to determine the hot section life. Several hundred thousand hours of operational service will be required before the demonstrated reliability of a fleet of engines or the design deficiencies of the engine hot section parts can be determined. Also, it may take three to four engine shop visits for heavy maintenance on the gas path hardware to establish cost effective build standards. Spare parts drive the oerator's engine maintenance costs but spare parts also makes lots of money for the engine manufacturer during the service life of an engine. Unless competition prevails for follow-on engine buys, there is really no motivation for an OEM to spend internal money to improve parts durability and reduce earnings derived from a lucrative spare parts business. If the hot section life is below design goals or promised values, the OEM migh argue that the engine is being operated beyond its basic design intent. On the other hand, the airframer and the operator will continue to remind the OEM that his engine was selected based on a lot of promises to deliver spec thrust with little impact on engine service life if higher thrust is used intermittently. In the end, a standoff prevails and nothing gets fixed. This briefing will propose ways to hold competing engine manufacturers more accountable for engine hot section design margins during the entire Engine Development process as well as provide tools to assess the design temperature margins in the hot section parts of Service Engines.

  5. Micro-CT scouting for transmission electron microscopy of human tissue specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morales, A. G.; Stempinski, E. S.; XIAO, X.

    Transmission electron microscopy (TEM) provides sub-nanometre-scale details in volumetric samples. Samples such as pathology tissue specimens are often stained with a metal element to enhance contrast, which makes them opaque to optical microscopes. As a result, it can be a lengthy procedure to find the region of interest inside a sample through sectioning. Here, we describe micro-CT scouting for TEM that allows noninvasive identification of regions of interest within a block sample to guide the sectioning step. In a tissue pathology study, a bench-top micro-CT scanner with 10 m resolution was used to determine the location of patches of themore » mucous membrane in osmium-stained human nasal scraping samples. Furthermore, once the regions of interest were located, the sample block was sectioned to expose that location, followed by ultra-thin sectioning and TEM to inspect the internal structure of the cilia of the membrane epithelial cells with nanometre resolution. This method substantially reduced the time and labour of the search process from typically 20 sections for light microscopy to three sections with no added sample preparation. Lay description Electron microscopy provides very high levels of detail in a small area, and thus the question of where to look in an opaque sample, such as a stained tissue specimen, needs to be answered by sectioning the sample in small steps and examining the sections under a light microscope, until the region of interest is found. The search process can be lengthy and labor intensive, especially for a study involving a large number of samples. Small areas of interest can be missed in the process if not enough regions are examined. We also describe a method to directly locate the region of interest within a whole sample using micro-CT imaging, bypassing the need of blindly sectioning. Micro-CT enables locating the region within 3D space; this information provides a guide for sectioning the sample to expose that precise location for high resolution electron microscopy imaging. In a human tissue specimen study, this method considerably reduced the time and labor of the search process.« less

  6. Micro-CT scouting for transmission electron microscopy of human tissue specimens

    DOE PAGES

    Morales, A. G.; Stempinski, E. S.; XIAO, X.; ...

    2016-02-08

    Transmission electron microscopy (TEM) provides sub-nanometre-scale details in volumetric samples. Samples such as pathology tissue specimens are often stained with a metal element to enhance contrast, which makes them opaque to optical microscopes. As a result, it can be a lengthy procedure to find the region of interest inside a sample through sectioning. Here, we describe micro-CT scouting for TEM that allows noninvasive identification of regions of interest within a block sample to guide the sectioning step. In a tissue pathology study, a bench-top micro-CT scanner with 10 m resolution was used to determine the location of patches of themore » mucous membrane in osmium-stained human nasal scraping samples. Furthermore, once the regions of interest were located, the sample block was sectioned to expose that location, followed by ultra-thin sectioning and TEM to inspect the internal structure of the cilia of the membrane epithelial cells with nanometre resolution. This method substantially reduced the time and labour of the search process from typically 20 sections for light microscopy to three sections with no added sample preparation. Lay description Electron microscopy provides very high levels of detail in a small area, and thus the question of where to look in an opaque sample, such as a stained tissue specimen, needs to be answered by sectioning the sample in small steps and examining the sections under a light microscope, until the region of interest is found. The search process can be lengthy and labor intensive, especially for a study involving a large number of samples. Small areas of interest can be missed in the process if not enough regions are examined. We also describe a method to directly locate the region of interest within a whole sample using micro-CT imaging, bypassing the need of blindly sectioning. Micro-CT enables locating the region within 3D space; this information provides a guide for sectioning the sample to expose that precise location for high resolution electron microscopy imaging. In a human tissue specimen study, this method considerably reduced the time and labor of the search process.« less

  7. Coronary artery calcium scoring does not add prognostic value to standard 64-section CT angiography protocol in low-risk patients suspected of having coronary artery disease.

    PubMed

    Kwon, Sung Woo; Kim, Young Jin; Shim, Jaemin; Sung, Ji Min; Han, Mi Eun; Kang, Dong Won; Kim, Ji-Ye; Choi, Byoung Wook; Chang, Hyuk-Jae

    2011-04-01

    To evaluate the prognostic outcome of cardiac computed tomography (CT) for prediction of major adverse cardiac events (MACEs) in low-risk patients suspected of having coronary artery disease (CAD) and to explore the differential prognostic values of coronary artery calcium (CAC) scoring and coronary CT angiography. Institutional review committee approval and informed consent were obtained. In 4338 patients who underwent 64-section CT for evaluation of suspected CAD, both CAC scoring and CT angiography were concurrently performed by using standard scanning protocols. Follow-up clinical outcome data regarding composite MACEs were procured. Multivariable Cox proportional hazards models were developed to predict MACEs. Risk-adjusted models incorporated traditional risk factors for CAC scoring and coronary CT angiography. During the mean follow-up of 828 days ± 380, there were 105 MACEs, for an event rate of 3%. The presence of obstructive CAD at coronary CT angiography had independent prognostic value, which escalated according to the number of stenosed vessels (P < .001). In the receiver operating characteristic curve (ROC) analysis, the superiority of coronary CT angiography to CAC scoring was demonstrated by a significantly greater area under the ROC curve (AUC) (0.892 vs 0.810, P < .001), whereas no significant incremental value for the addition of CAC scoring to coronary CT angiography was established (AUC = 0.892 for coronary CT angiography alone vs 0.902 with addition of CAC scoring, P = .198). Coronary CT angiography is better than CAC scoring in predicting MACEs in low-risk patients suspected of having CAD. Furthermore, the current standard multisection CT protocol (coronary CT angiography combined with CAC scoring) has no incremental prognostic value compared with coronary CT angiography alone. Therefore, in terms of determining prognosis, CAC scoring may no longer need to be incorporated in the cardiac CT protocol in this population. © RSNA, 2011.

  8. Charge Separation and Exciton Dynamics at Polymer/ZnO Interface from First-Principles Simulations.

    PubMed

    Wu, Guangfen; Li, Zi; Zhang, Xu; Lu, Gang

    2014-08-07

    Charge separation and exciton dynamics play a crucial role in determining the performance of excitonic photovoltaics. Using time-dependent density functional theory with a range-separated exchange-correlation functional as well as nonadiabatic ab initio molecular dynamics, we have studied the formation and dynamics of charge-transfer (CT) excitons at polymer/ZnO interface. The interfacial atomic structure, exciton density of states and conversions between exciton species are examined from first-principles. The exciton dynamics exhibits both adiabatic and nonadiabatic characters. While the adiabatic transitions are facilitated by C═C vibrations along the polymer (P3HT) backbone, the nonadiabatic transitions are realized by exciton hopping between the excited states. We find that the localized ZnO surface states lead to localized low-energy CT states and poor charge separation. In contrast, the surface states of crystalline C60 are indistinguishable from the bulk states, resulting in delocalized CT states and efficient charge separation in polymer/fullerene (P3HT/PCBM) heterojunctions. The hot CT states are found to cool down in an ultrafast time scale and may not play a major role in charge separation of P3HT/ZnO. Finally we suggest that the dimensions of nanostructured acceptors can be tuned to obtain both efficient charge separation and high open circuit voltages.

  9. Contingency power for a small turboshaft engine by using water injection into turbine cooling air

    NASA Technical Reports Server (NTRS)

    Biesiadny, Thomas J.; Klann, Gary A.

    1992-01-01

    Because of one-engine-inoperative (OEI) requirements, together with hot-gas reingestion and hot-day, high-altitude take-off situations, power augmentation for multiengine rotorcraft has always been of critical interest. However, power augmentation by using overtemperature at the turbine inlet will shorten turbine life unless a method of limiting thermal and mechanical stress is found. A possible solution involves allowing the turbine inlet temperature to rise to augment power while injecting water into the turbine cooling air to limit hot-section metal temperatures. An experimental water injection device was installed in an engine and successfully tested. Although concern for unprotected subcomponents in the engine hot section prevented demonstration of the technique's maximum potential, it was still possible to demonstrate increases in power while maintaining nearly constant turbine rotor blade temperature.

  10. Development of a Multileaf Collimator for Proton Therapy

    DTIC Science & Technology

    2012-11-01

    Hounsfield Units (HU) into density bins (of width 10 kg/m^3), we now define a unique density for each Hounsfield Unit . The density resolution is thus...patient basis given some knowledge about any implants they might have. 24 The calibration of CT Hounsfield unit to material type and density was...that region, resulting in a hot ring around the cold spot. It was determined that the Hounsfield unit values corresponding to the voxels in the cold

  11. Phase-contrast x-ray computed tomography for observing biological specimens and organic materials

    NASA Astrophysics Data System (ADS)

    Momose, Atsushi; Takeda, Tohoru; Itai, Yuji

    1995-02-01

    A novel three-dimensional x-ray imaging method has been developed by combining a phase-contrast x-ray imaging technique with x-ray computed tomography. This phase-contrast x-ray computed tomography (PCX-CT) provides sectional images of organic specimens that would produce absorption-contrast x-ray CT images with little contrast. Comparing PCX-CT images of rat cerebellum and cancerous rabbit liver specimens with corresponding absorption-contrast CT images shows that PCX-CT is much more sensitive to the internal structure of organic specimens.

  12. Automatic radiation dose monitoring for CT of trauma patients with different protocols: feasibility and accuracy.

    PubMed

    Higashigaito, K; Becker, A S; Sprengel, K; Simmen, H-P; Wanner, G; Alkadhi, H

    2016-09-01

    To demonstrate the feasibility and accuracy of automatic radiation dose monitoring software for computed tomography (CT) of trauma patients in a clinical setting over time, and to evaluate the potential of radiation dose reduction using iterative reconstruction (IR). In a time period of 18 months, data from 378 consecutive thoraco-abdominal CT examinations of trauma patients were extracted using automatic radiation dose monitoring software, and patients were split into three cohorts: cohort 1, 64-section CT with filtered back projection, 200 mAs tube current-time product; cohort 2, 128-section CT with IR and identical imaging protocol; cohort 3, 128-section CT with IR, 150 mAs tube current-time product. Radiation dose parameters from the software were compared with the individual patient protocols. Image noise was measured and image quality was semi-quantitatively determined. Automatic extraction of radiation dose metrics was feasible and accurate in all (100%) patients. All CT examinations were of diagnostic quality. There were no differences between cohorts 1 and 2 regarding volume CT dose index (CTDIvol; p=0.62), dose-length product (DLP), and effective dose (ED, both p=0.95), while noise was significantly lower (chest and abdomen, both -38%, p<0.017). Compared to cohort 1, CTDIvol, DLP, and ED in cohort 3 were significantly lower (all -25%, p<0.017), similar to the noise in the chest (-32%) and abdomen (-27%, both p<0.017). Compared to cohort 2, CTDIvol (-28%), DLP, and ED (both -26%) in cohort 3 was significantly lower (all, p<0.017), while noise in the chest (+9%) and abdomen (+18%) was significantly higher (all, p<0.017). Automatic radiation dose monitoring software is feasible and accurate, and can be implemented in a clinical setting for evaluating the effects of lowering radiation doses of CT protocols over time. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. On 3-D inelastic analysis methods for hot section components. Volume 1: Special finite element models

    NASA Technical Reports Server (NTRS)

    Nakazawa, S.

    1987-01-01

    This Annual Status Report presents the results of work performed during the third year of the 3-D Inelastic Analysis Methods for Hot Section Components program (NASA Contract NAS3-23697). The objective of the program is to produce a series of new computer codes that permit more accurate and efficient three-dimensional analysis of selected hot section components, i.e., combustor liners, turbine blades, and turbine vanes. The computer codes embody a progression of mathematical models and are streamlined to take advantage of geometrical features, loading conditions, and forms of material response that distinguish each group of selected components. This report is presented in two volumes. Volume 1 describes effort performed under Task 4B, Special Finite Element Special Function Models, while Volume 2 concentrates on Task 4C, Advanced Special Functions Models.

  14. Cadaveric verification of the Eclipse AAA algorithm for spine SBRT treatments with titanium hardware.

    PubMed

    Grams, Michael P; Fong de Los Santos, Luis E; Antolak, John A; Brinkmann, Debra H; Clarke, Michelle J; Park, Sean S; Olivier, Kenneth R; Whitaker, Thomas J

    2016-01-01

    To assess the accuracy of the Eclipse Analytical Anisotropic Algorithm when calculating dose for spine stereotactic body radiation therapy treatments involving surgically implanted titanium hardware. A human spine was removed from a cadaver, cut sagittally along the midline, and then separated into thoracic and lumbar sections. The thoracic section was implanted with titanium stabilization hardware; the lumbar section was not implanted. Spine sections were secured in a water phantom and simulated for treatment planning using both standard and extended computed tomography (CT) scales. Target volumes were created on both spine sections. Dose calculations were performed using (1) the standard CT scale with relative electron density (RED) override of image artifacts and hardware, (2) the extended CT scale with RED override of image artifacts only, and (3) the standard CT scale with no RED overrides for hardware or artifacts. Plans were delivered with volumetric modulated arc therapy using a 6-MV beam with and without a flattening filter. A total of 3 measurements for each plan were made with Gafchromic film placed between the spine sections and compared with Eclipse dose calculations using gamma analysis with a 2%/2 mm passing criteria. A single measurement in a homogeneous phantom was made for each plan before actual delivery. Gamma passing rates for measurements in the homogeneous phantom were 99.6% or greater. Passing rates for measurements made in the lumbar spine section without hardware were 99.3% or greater; measurements made in the thoracic spine containing titanium were 98.6 to 99.5%. Eclipse Analytical Anisotropic Algorithm can adequately model the effects of titanium implants for spine stereotactic body radiation therapy treatments using volumetric modulated arc therapy. Calculations with standard or extended CT scales give similarly accurate results. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  15. Impact of the HERA I+II combined data on the CT14 QCD global analysis

    NASA Astrophysics Data System (ADS)

    Dulat, S.; Hou, T.-J.; Gao, J.; Guzzi, M.; Huston, J.; Nadolsky, P.; Pumplin, J.; Schmidt, C.; Stump, D.; Yuan, C.-P.

    2016-11-01

    A brief description of the impact of the recent HERA run I+II combination of inclusive deep inelastic scattering cross-section data on the CT14 global analysis of PDFs is given. The new CT14HERA2 PDFs at NLO and NNLO are illustrated. They employ the same parametrization used in the CT14 analysis, but with an additional shape parameter for describing the strange quark PDF. The HERA I+II data are reasonably well described by both CT14 and CT14HERA2 PDFs, and differences are smaller than the PDF uncertainties of the standard CT14 analysis. Both sets are acceptable when the error estimates are calculated in the CTEQ-TEA (CT) methodology and the standard CT14 PDFs are recommended to be continuously used for the analysis of LHC measurements.

  16. A&M. TAN607. Section views of hot shop. Section E shows ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607. Section views of hot shop. Section E shows equipment areas along rear wall. Section F shows storage pool cut along east/west line. Roof trusses, shelves along sides of pool, drain, roof trusses, shelves along sides of pool, drain, and sump. Section G cuts along north/south to show centerline of turntables, manipulator arms, O-man bridge, crane bridge. Referent drawing is ID-33-E-158 above. Ralph M. Parsons 902-3-ANP-607-A 107. Date: December 1952, but as-built in 1982. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106759 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  17. A&M. TAN633. Sections show view of hot cell caskentry doors, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-633. Sections show view of hot cell cask-entry doors, manipulators in each cell, drainage trenches, door and room details. Ralph M. Parsons 1229-13-ANP/GE-3-633-A-2. Date: December 1956. Approved by INEEL Classification Office for public release. INNEL index code no. 034-0633-00-693-107316 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  18. Analysis of pulmonary pure ground-glass nodule in enhanced dual energy CT imaging for predicting invasive adenocarcinoma: comparing with conventional thin-section CT imaging

    PubMed Central

    Zhang, Ying; Tang, Jian; Xu, Jianrong

    2017-01-01

    Background To investigate the value of dual energy computed tomography (DECT) parameters (including iodine concentration and monochromatic CT numbers) for predicting pure ground-glass nodules (pGGNs) of invasive adenocarcinoma (IA). Methods A total of 55 resected pGGNs evaluated with both unenhanced thin-section CT (TSCT) and enhanced DECT scans were included. Correlations between histopathology [adenocarcinoma in situ (AIS), minimally IA (MIA), and IA] and CT scan characteristics were examined. CT scan and clinicodemographic data were investigated by univariate and multivariate analysis to identify features that helped distinguish IA from AIS or MIA. Results Both normalized iodine concentration (NIC) of IA and slope of spectral curve [slope(k)] were not significantly different between IA and AIS or MIA. Size, performance of pleural retraction and enhanced monochromatic CT attenuation values of 120–140 keV were significantly higher for IA. In multivariate regression analysis, size and enhanced monochromatic CT number of 140 keV were independent predictors for IA. Using the two parameters together, the diagnostic capacity of IA could be improved from 0.697 or 0.635 to 0.713. Conclusions DECT could help demonstrate blood supply and indicate invasion extent of pGGNs, and monochromatic CT number of higher energy (especially 140 keV) would be better for diagnosing IA than lower energies. Together with size of pGGNs, the diagnostic capacity of IA could be better. PMID:29312701

  19. Comparison of conventional and synchrotron-radiation-based microtomography of bone around dental implants

    NASA Astrophysics Data System (ADS)

    Cattaneo, Paolo M.; Dalstra, Michel; Beckmann, Felix; Donath, Tilman; Melsen, Birte

    2004-10-01

    This study explores the application of conventional micro tomography (μCT) and synchrotron radiation (SR) based μCT to evaluate the bone around titanium dental implants. The SR experiment was performed at beamline W2 of HASYLAB at DESY using a monochromatic X-ray beam of 50 keV. The testing material consisted of undecalcified bone segments harvested from the upper jaw of a macaca fascicularis monkey each containing a titanium dental implant. The results from the two different techniques were qualitatively compared with conventional histological sections examined under light microscopy. The SR-based μCT produced images that, especially at the bone-implant interface, are less noisy and sharper than the ones obtained with conventional μCT. For the proper evaluation of the implant-bone interface, only the SR-based μCT technique is able to display the areas of bony contact and visualize the true 3D structure of bone around dental implants correctly. This investigation shows that both conventional and SR-based μCT scanning techniques are non-destructive methods, which provide detailed images of bone. However with SR-based μCT it is possible to obtain an improved image quality of the bone surrounding dental implants, which display a level of detail comparable to histological sections. Therefore, SR-based μCT scanning could represent a valid, unbiased three-dimensional alternative to evaluate osseointegration of dental implants

  20. Virtual tissue alignment and cutting plane definition – a new method to obtain optimal longitudinal histological sections

    PubMed Central

    Danz, J C; Habegger, M; Bosshardt, D D; Katsaros, C; Stavropoulos, A

    2014-01-01

    Histomorphometric evaluation of the buccal aspects of periodontal tissues in rodents requires reproducible alignment of maxillae and highly precise sections containing central sections of buccal roots; this is a cumbersome and technically sensitive process due to the small specimen size. The aim of the present report is to describe and analyze a method to transfer virtual sections of micro-computer tomographic (CT)-generated image stacks to the microtome for undecalcified histological processing and to describe the anatomy of the periodontium in rat molars. A total of 84 undecalcified sections of all buccal roots of seven untreated rats was analyzed. The accuracy of section coordinate transfer from virtual micro-CT slice to the histological slice, right–left side differences and the measurement error for linear and angular measurements on micro-CT and on histological micrographs were calculated using the Bland–Altman method, interclass correlation coefficient and the method of moments estimator. Also, manual alignment of the micro-CT-scanned rat maxilla was compared with multiplanar computer-reconstructed alignment. The supra alveolar rat anatomy is rather similar to human anatomy, whereas the alveolar bone is of compact type and the keratinized gingival epithelium bends apical to join the junctional epithelium. The high methodological standardization presented herein ensures retrieval of histological slices with excellent display of anatomical microstructures, in a reproducible manner, minimizes random errors, and thereby may contribute to the reduction of number of animals needed. PMID:24266502

  1. Enabling Technologies for Ceramic Hot Section Components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venkat Vedula; Tania Bhatia

    Silicon-based ceramics are attractive materials for use in gas turbine engine hot sections due to their high temperature mechanical and physical properties as well as lower density than metals. The advantages of utilizing ceramic hot section components include weight reduction, and improved efficiency as well as enhanced power output and lower emissions as a result of reducing or eliminating cooling. Potential gas turbine ceramic components for industrial, commercial and/or military high temperature turbine applications include combustor liners, vanes, rotors, and shrouds. These components require materials that can withstand high temperatures and pressures for long duration under steam-rich environments. For Navymore » applications, ceramic hot section components have the potential to increase the operation range. The amount of weight reduced by utilizing a lighter gas turbine can be used to increase fuel storage capacity while a more efficient gas turbine consumes less fuel. Both improvements enable a longer operation range for Navy ships and aircraft. Ceramic hot section components will also be beneficial to the Navy's Growth Joint Strike Fighter (JSF) and VAATE (Versatile Affordable Advanced Turbine Engines) initiatives in terms of reduced weight, cooling air savings, and capability/cost index (CCI). For DOE applications, ceramic hot section components provide an avenue to achieve low emissions while improving efficiency. Combustors made of ceramic material can withstand higher wall temperatures and require less cooling air. Ability of the ceramics to withstand high temperatures enables novel combustor designs that have reduced NO{sub x}, smoke and CO levels. In the turbine section, ceramic vanes and blades do not require sophisticated cooling schemes currently used for metal components. The saved cooling air could be used to further improve efficiency and power output. The objectives of this contract were to develop technologies critical for ceramic hot section components for gas turbine engines. Significant technical progress has been made towards maturation of the EBC and CMC technologies for incorporation into gas turbine engine hot-section. Promising EBC candidates for longer life and/or higher temperature applications relative to current state of the art BSAS-based EBCs have been identified. These next generation coating systems have been scaled-up from coupons to components and are currently being field tested in Solar Centaur 50S engine. CMC combustor liners were designed, fabricated and tested in a FT8 sector rig to demonstrate the benefits of a high temperature material system. Pretest predictions made through the use of perfectly stirred reactor models showed a 2-3x benefit in CO emissions for CMC versus metallic liners. The sector-rig test validated the pretest predictions with >2x benefit in CO at the same NOx levels at various load conditions. The CMC liners also survived several trip shut downs thereby validating the CMC design methodology. Significant technical progress has been made towards incorporation of ceramic matrix composites (CMC) and environmental barrier coatings (EBC) technologies into gas turbine engine hot-section. The second phase of the program focused on the demonstration of a reverse flow annular CMC combustor. This has included overcoming the challenges of design and fabrication of CMCs into 'complex' shapes; developing processing to apply EBCs to 'engine hardware'; testing of an advanced combustor enabled by CMCs in a PW206 rig; and the validation of performance benefits against a metal baseline. The rig test validated many of the pretest predictions with a 40-50% reduction in pattern factor compared to the baseline and reductions in NOx levels at maximum power conditions. The next steps are to develop an understanding of the life limiting mechanisms in EBC and CMC materials, developing a design system for EBC coated CMCs and durability testing in an engine environment.« less

  2. Hydration and Hot Yoga: Encouragement, Behaviors, and Outcomes.

    PubMed

    Mace Firebaugh, Casey J; Eggleston, Brandon

    2017-01-01

    Currently, the literature on hot yoga is lacking, and there is still much to understand regarding the safety of these practices. However, one point of safety often emphasized is hydration during the practice of hot yoga. The aim of this study was to examine hydration encouragement by hot yoga instructors and hydration behaviors and related outcomes by hot yoga participants. A cross-sectional study ( n = 700) collected self-report data on demographics, types and frequency of yoga practiced, hydration behaviors, and self-report measures of adverse outcomes experienced by participants during hot yoga. Associations between hydration encouragement, protective behaviors, and adverse outcomes were analyzed through Chi-square tests. Every protective hydration behavior was significantly associated with instructor encouragement ( P < 0.05). Hydration before or during hot yoga participation was associated with a lower occurrence of dehydration symptoms ( P < 0.05). Hot yoga instructors hold a key role in encouraging hydration and student safety outcomes.

  3. 46 CFR 53.05-2 - Relief valve requirements for hot water boilers (modifies HG-400.2).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Relief valve requirements for hot water boilers (modifies HG-400.2). 53.05-2 Section 53.05-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-2 Relief valve requirements for hot water boilers (modifies HG...

  4. 46 CFR 53.05-2 - Relief valve requirements for hot water boilers (modifies HG-400.2).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Relief valve requirements for hot water boilers (modifies HG-400.2). 53.05-2 Section 53.05-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-2 Relief valve requirements for hot water boilers (modifies HG...

  5. 46 CFR 53.05-2 - Relief valve requirements for hot water boilers (modifies HG-400.2).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Relief valve requirements for hot water boilers (modifies HG-400.2). 53.05-2 Section 53.05-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-2 Relief valve requirements for hot water boilers (modifies HG...

  6. 46 CFR 53.05-2 - Relief valve requirements for hot water boilers (modifies HG-400.2).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Relief valve requirements for hot water boilers (modifies HG-400.2). 53.05-2 Section 53.05-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-2 Relief valve requirements for hot water boilers (modifies HG...

  7. 46 CFR 53.05-2 - Relief valve requirements for hot water boilers (modifies HG-400.2).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Relief valve requirements for hot water boilers (modifies HG-400.2). 53.05-2 Section 53.05-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-2 Relief valve requirements for hot water boilers (modifies HG...

  8. [Application of computed tomography (CT) examination for forensic medicine].

    PubMed

    Urbanik, Andrzej; Chrzan, Robert

    2013-01-01

    The aim of the study is to present a own experiences in usage of post mortem CT examination for forensic medicine. With the help of 16-slice CT scanner 181 corpses were examined. Obtained during acquisition imaging data are later developed with dedicated programmes. Analyzed images were extracted from axial sections, multiplanar reconstructions as well as 3D reconstructions. Gained information helped greatly when classical autopsy was performed by making it more accurate. A CT scan images recorded digitally enable to evaluate corpses at any time, despite processes of putrefaction or cremation. If possible CT examination should precede classical autopsy.

  9. Cause of Legionnaire's Disease outbreak at hospital traced.

    PubMed

    1995-03-01

    The cause of an outbreak of Legionnaire's Disease at St. Vincent's Medical Center, Bridgeport, CT, has been traced to the hospital's hot water system after months of testing and decontamination efforts. A total of 28 patients were diagnosed with the disease between January and October 1994, with most of the cases occurring in June and July. Legionnaire's Disease is a kind of pneumonia caused by bacteria that thrive in warm water and can become airborne on tiny water droplets that, if inhaled, spread the disease.

  10. Three Dimensional Imaging of Paraffin Embedded Human Lung Tissue Samples by Micro-Computed Tomography

    PubMed Central

    Scott, Anna E.; Vasilescu, Dragos M.; Seal, Katherine A. D.; Keyes, Samuel D.; Mavrogordato, Mark N.; Hogg, James C.; Sinclair, Ian; Warner, Jane A.; Hackett, Tillie-Louise; Lackie, Peter M.

    2015-01-01

    Background Understanding the three-dimensional (3-D) micro-architecture of lung tissue can provide insights into the pathology of lung disease. Micro computed tomography (µCT) has previously been used to elucidate lung 3D histology and morphometry in fixed samples that have been stained with contrast agents or air inflated and dried. However, non-destructive microstructural 3D imaging of formalin-fixed paraffin embedded (FFPE) tissues would facilitate retrospective analysis of extensive tissue archives of lung FFPE lung samples with linked clinical data. Methods FFPE human lung tissue samples (n = 4) were scanned using a Nikon metrology µCT scanner. Semi-automatic techniques were used to segment the 3D structure of airways and blood vessels. Airspace size (mean linear intercept, Lm) was measured on µCT images and on matched histological sections from the same FFPE samples imaged by light microscopy to validate µCT imaging. Results The µCT imaging protocol provided contrast between tissue and paraffin in FFPE samples (15mm x 7mm). Resolution (voxel size 6.7 µm) in the reconstructed images was sufficient for semi-automatic image segmentation of airways and blood vessels as well as quantitative airspace analysis. The scans were also used to scout for regions of interest, enabling time-efficient preparation of conventional histological sections. The Lm measurements from µCT images were not significantly different to those from matched histological sections. Conclusion We demonstrated how non-destructive imaging of routinely prepared FFPE samples by laboratory µCT can be used to visualize and assess the 3D morphology of the lung including by morphometric analysis. PMID:26030902

  11. Measurement of cardiac output from dynamic pulmonary circulation time CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yee, Seonghwan, E-mail: Seonghwan.Yee@Beaumont.edu; Scalzetti, Ernest M.

    Purpose: To introduce a method of estimating cardiac output from the dynamic pulmonary circulation time CT that is primarily used to determine the optimal time window of CT pulmonary angiography (CTPA). Methods: Dynamic pulmonary circulation time CT series, acquired for eight patients, were retrospectively analyzed. The dynamic CT series was acquired, prior to the main CTPA, in cine mode (1 frame/s) for a single slice at the level of the main pulmonary artery covering the cross sections of ascending aorta (AA) and descending aorta (DA) during the infusion of iodinated contrast. The time series of contrast changes obtained for DA,more » which is the downstream of AA, was assumed to be related to the time series for AA by the convolution with a delay function. The delay time constant in the delay function, representing the average time interval between the cross sections of AA and DA, was determined by least square error fitting between the convoluted AA time series and the DA time series. The cardiac output was then calculated by dividing the volume of the aortic arch between the cross sections of AA and DA (estimated from the single slice CT image) by the average time interval, and multiplying the result by a correction factor. Results: The mean cardiac output value for the six patients was 5.11 (l/min) (with a standard deviation of 1.57 l/min), which is in good agreement with the literature value; the data for the other two patients were too noisy for processing. Conclusions: The dynamic single-slice pulmonary circulation time CT series also can be used to estimate cardiac output.« less

  12. Selection of a turbine cooling system applying multi-disciplinary design considerations.

    PubMed

    Glezer, B

    2001-05-01

    The presented paper describes a multi-disciplinary cooling selection approach applied to major gas turbine engine hot section components, including turbine nozzles, blades, discs, combustors and support structures, which maintain blade tip clearances. The paper demonstrates benefits of close interaction between participating disciplines starting from early phases of the hot section development. The approach targets advancements in engine performance and cost by optimizing the design process, often requiring compromises within individual disciplines.

  13. Processing of Advanced Ceramics Which Have Potential for Use in Gas Turbine Aero Engines

    DTIC Science & Technology

    1989-02-01

    reaons . Details on the availability of these publications may be obtained from: Graphics Section, National Research Council Canada, National...have been produced by hot isostatic pressing (HIP’ing) have good potential to be used as hot section components in gas turbine aero engines. This...Alumina, for example, maintains good corrosion resistance, good stiffness, and good strength at high temperatures, but exhibits very poor thermal shock

  14. A correlative approach for combining microCT, light and transmission electron microscopy in a single 3D scenario

    PubMed Central

    2013-01-01

    Background In biomedical research, a huge variety of different techniques is currently available for the structural examination of small specimens, including conventional light microscopy (LM), transmission electron microscopy (TEM), confocal laser scanning microscopy (CLSM), microscopic X-ray computed tomography (microCT), and many others. Since every imaging method is physically limited by certain parameters, a correlative use of complementary methods often yields a significant broader range of information. Here we demonstrate the advantages of the correlative use of microCT, light microscopy, and transmission electron microscopy for the analysis of small biological samples. Results We used a small juvenile bivalve mollusc (Mytilus galloprovincialis, approximately 0.8 mm length) to demonstrate the workflow of a correlative examination by microCT, LM serial section analysis, and TEM-re-sectioning. Initially these three datasets were analyzed separately, and subsequently they were fused in one 3D scene. This workflow is very straightforward. The specimen was processed as usual for transmission electron microscopy including post-fixation in osmium tetroxide and embedding in epoxy resin. Subsequently it was imaged with microCT. Post-fixation in osmium tetroxide yielded sufficient X-ray contrast for microCT imaging, since the X-ray absorption of epoxy resin is low. Thereafter, the same specimen was serially sectioned for LM investigation. The serial section images were aligned and specific organ systems were reconstructed based on manual segmentation and surface rendering. According to the region of interest (ROI), specific LM sections were detached from the slides, re-mounted on resin blocks and re-sectioned (ultrathin) for TEM. For analysis, image data from the three different modalities was co-registered into a single 3D scene using the software AMIRA®. We were able to register both the LM section series volume and TEM slices neatly to the microCT dataset, with small geometric deviations occurring only in the peripheral areas of the specimen. Based on co-registered datasets the excretory organs, which were chosen as ROI for this study, could be investigated regarding both their ultrastructure as well as their position in the organism and their spatial relationship to adjacent tissues. We found structures typical for mollusc excretory systems, including ultrafiltration sites at the pericardial wall, and ducts leading from the pericardium towards the kidneys, which exhibit a typical basal infolding system. Conclusions The presented approach allows a comprehensive analysis and presentation of small objects regarding both the overall organization as well as cellular and subcellular details. Although our protocol involves a variety of different equipment and procedures, we maintain that it offers savings in both effort and cost. Co-registration of datasets from different imaging modalities can be accomplished with high-end desktop computers and offers new opportunities for understanding and communicating structural relationships within organisms and tissues. In general, the correlative use of different microscopic imaging techniques will continue to become more widespread in morphological and structural research in zoology. Classical TEM serial section investigations are extremely time consuming, and modern methods for 3D analysis of ultrastructure such as SBF-SEM and FIB-SEM are limited to very small volumes for examination. Thus the re-sectioning of LM sections is suitable for speeding up TEM examination substantially, while microCT could become a key-method for complementing ultrastructural examinations. PMID:23915384

  15. Aerothermal modeling. Executive summary

    NASA Technical Reports Server (NTRS)

    Kenworthy, M. K.; Correa, S. M.; Burrus, D. L.

    1983-01-01

    One of the significant ways in which the performance level of aircraft turbine engines has been improved is by the use of advanced materials and cooling concepts that allow a significant increase in turbine inlet temperature level, with attendant thermodynamic cycle benefits. Further cycle improvements have been achieved with higher pressure ratio compressors. The higher turbine inlet temperatures and compressor pressure ratios with corresponding higher temperature cooling air has created a very hostile environment for the hot section components. To provide the technology needed to reduce the hot section maintenance costs, NASA has initiated the Hot Section Technology (HOST) program. One key element of this overall program is the Aerothermal Modeling Program. The overall objective of his program is to evolve and validate improved analysis methods for use in the design of aircraft turbine engine combustors. The use of such combustor analysis capabilities can be expected to provide significant improvement in the life and durability characteristics of both combustor and turbine components.

  16. Field trials of asphalt rubber hot mix in Virginia.

    DOT National Transportation Integrated Search

    1995-01-01

    Four test sections using asphalt rubber hot mix were placed in Virginia during the period of 1990 through 1993. The purpose of these installations was to familiarize both contractors and Virginia Department of Transportation (VDOT) personnel with the...

  17. Tidd hot gas clean up program. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This Final Report on the Tidd Hot Gas Clean Up Program covers the period from initial Proof-of-Concept testing in August, 1990, through final equipment inspections in May, 1995. The Tidd Hot Gas Clean Up (HGCU) system was installed in the Tidd Pressurized Fluidized Bed Combustion (PFBC) Demonstration Plant, which is the first utility-scale PFBC plant in the United States. Detailed design work on the project began in July, 1990, and site construction began in December, 1991. Initial operation of the system occurred in May, 1992, and the hot gas filter was commissioned in October, 1992. The test program ended inmore » March, 1995, when the Tidd Plant was shut down following its four-year test program. Section 1.0 of this report is an executive summary of the project covering the project background, system description, test results and conclusions. Section 2.0 is an introduction covering the program objectives and schedule. Section 3.0 provides detailed descriptions of the system and its major components. Section 4.0 provides detailed results of all testing including observations and posttest inspection results. Sections 5.0 and 6.0 list the program conclusions and recommendations, respectively. Appendix I is a report prepared by Southern Research Institute on the properties of Tidd PFBC ash sampled during the test program. Appendix II is a report prepared by Westinghouse STC on the performance of candle filter fail-safe regenerator devices.« less

  18. Additive Manufacturing of IN100 Superalloy Through Scanning Laser Epitaxy for Turbine Engine Hot-Section Component Repair: Process Development, Modeling, Microstructural Characterization, and Process Control

    NASA Astrophysics Data System (ADS)

    Acharya, Ranadip; Das, Suman

    2015-09-01

    This article describes additive manufacturing (AM) of IN100, a high gamma-prime nickel-based superalloy, through scanning laser epitaxy (SLE), aimed at the creation of thick deposits onto like-chemistry substrates for enabling repair of turbine engine hot-section components. SLE is a metal powder bed-based laser AM technology developed for nickel-base superalloys with equiaxed, directionally solidified, and single-crystal microstructural morphologies. Here, we combine process modeling, statistical design-of-experiments (DoE), and microstructural characterization to demonstrate fully metallurgically bonded, crack-free and dense deposits exceeding 1000 μm of SLE-processed IN100 powder onto IN100 cast substrates produced in a single pass. A combined thermal-fluid flow-solidification model of the SLE process compliments DoE-based process development. A customized quantitative metallography technique analyzes digital cross-sectional micrographs and extracts various microstructural parameters, enabling process model validation and process parameter optimization. Microindentation measurements show an increase in the hardness by 10 pct in the deposit region compared to the cast substrate due to microstructural refinement. The results illustrate one of the very few successes reported for the crack-free deposition of IN100, a notoriously "non-weldable" hot-section alloy, thus establishing the potential of SLE as an AM method suitable for hot-section component repair and for future new-make components in high gamma-prime containing crack-prone nickel-based superalloys.

  19. [The role of whole body 2-[fluorine-18]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in the management of unknown primary tumors].

    PubMed

    Wu, Zhi-Jian; Zhang, Yong-Xue; Wei, Hao; Jia, Qing

    2007-08-28

    To assess the role of 2-[fluorine-18]-fluoro-2-deoxy-D-glucose ((18)F-FDG) positron emission tomography/computed tomography (PET/CT) in the management of unknown primary primary (CUP) with metastatic loci. Thirty-four patients of CUP with metastatic loci who had undergone unsuccessful conventional diagnostic work-up underwent (18)F-FDG PET/CT. The images thus obtained were analyzed with visual and semi-quantitative methods. Histopathology, cytology, and/or follow-up were used to evaluate the PET/CT results. In 20 of the 34 patients (18)F-FDG PET/CT showed focal tracer accumulations corresponding to potential primary tumor sites located in the lung (n = 9), colon (n = 3), rectum (n = 2), pancreas (n = 1), right aryepiglottic wall (n = 1), esophagus (n = 1), breast (n = 1), and ovary (n = 2). The detection rate of primary tumor by (18)F-FDG PET/CT was 50.0% (17/34), the primary tumors were identified in the lung (n = 8), colon (n = 2), rectum (n = 1), pancreas (n = 1), right aryepiglottic wall (n = 1), esophagus (n = 1), ovary (n = 2), and breast (n = 1). The false positive rate was 8.8% (3/34) with the diagnosis of primary tumor in the lung (n = 1), colon (n = 1), and rectum (n = 1) to be identified as false. In 14 of the 34 patients, (18)F-FDG PET/CT did not reveal lesions suspected to be the primary tumor sites in 13 patients, and it was impossible to identify one lesion as the most likely primary tumor in one patient due to the presence of multiple hot spots in several organs. The (18)F-FDG PET/CT findings affected the medical management in 17 of the 34 (50.0%) patients due to the finding of primary sites and/or additional metastases. (18)F-FDG PET/CT has relevant impact on the therapeutic management of patients with unknown primary tumor. It is recommended that (18)F-FDG PET/CT be performed in the patient with unknown primary tumor after unsuccessful conventional diagnostic workup.

  20. A pilot study using low-dose Spectral CT and ASIR (Adaptive Statistical Iterative Reconstruction) algorithm to diagnose solitary pulmonary nodules.

    PubMed

    Xiao, Huijuan; Liu, Yihe; Tan, Hongna; Liang, Pan; Wang, Bo; Su, Lei; Wang, Suya; Gao, Jianbo

    2015-11-17

    Lung cancer is the most common cancer which has the highest mortality rate. With the development of computed tomography (CT) techniques, the case detection rates of solitary pulmonary nodules (SPN) has constantly increased and the diagnosis accuracy of SPN has remained a hot topic in clinical and imaging diagnosis. The aim of this study was to evaluate the combination of low-dose spectral CT and ASIR (Adaptive Statistical Iterative Reconstruction) algorithm in the diagnosis of solitary pulmonary nodules (SPN). 62 patients with SPN (42 cases of benign SPN and 20 cases of malignant SPN, pathology confirmed) were scanned by spectral CT with a dual-phase contrast-enhanced method. The iodine and water concentration (IC and WC) of the lesion and the artery in the image that had the same density were measured by the GSI (Gemstone Spectral Imaging) software. The normalized iodine and water concentration (NIC and NWC) of the lesion and the normalized iodine and water concentration difference (ICD and WCD) between the arterial and venous phases (AP and VP) were also calculated. The spectral HU (Hounsfield Unit ) curve was divided into 3 sections based on the energy (40-70, 70-100 and 100-140 keV) and the slopes (λHU) in both phases were calculated. The ICAP, ICVP, WCAP and WCVP, NIC and NWC, and the λHU in benign and malignant SPN were compared by independent sample t-test. The iodine related parameters (ICAP, ICVP, NICAP, NICVP, and the ICD) of malignant SPN were significantly higher than that of benign SPN (t = 3.310, 1.330, 2.388, 1.669 and 3.251, respectively, P <0.05). The 3 λHU values of venous phase in malignant SPN were higher than that of benign SPN (t = 3.803, 2.846 and 3.205, P <0.05). The difference of water related parameters (WCAP, WCVP, NWCAP, NWCVP and WCD) between malignant and benign SPN were not significant (t = 0.666, 0.257, 0.104, 0.550 and 0.585, P > 0.05). The iodine related parameters and the slope of spectral curve are useful markers to distinguish the benign from the malignant lung diseases, and its application is extremely feasible in clinical applications.

  1. μCT of ex-vivo stained mouse hearts and embryos enables a precise match between 3D virtual histology, classical histology and immunochemistry

    PubMed Central

    Larsson, Emanuel; Martin, Sabine; Lazzarini, Marcio; Tromba, Giuliana; Missbach-Guentner, Jeannine; Pinkert-Leetsch, Diana; Katschinski, Dörthe M.; Alves, Frauke

    2017-01-01

    The small size of the adult and developing mouse heart poses a great challenge for imaging in preclinical research. The aim of the study was to establish a phosphotungstic acid (PTA) ex-vivo staining approach that efficiently enhances the x-ray attenuation of soft-tissue to allow high resolution 3D visualization of mouse hearts by synchrotron radiation based μCT (SRμCT) and classical μCT. We demonstrate that SRμCT of PTA stained mouse hearts ex-vivo allows imaging of the cardiac atrium, ventricles, myocardium especially its fibre structure and vessel walls in great detail and furthermore enables the depiction of growth and anatomical changes during distinct developmental stages of hearts in mouse embryos. Our x-ray based virtual histology approach is not limited to SRμCT as it does not require monochromatic and/or coherent x-ray sources and even more importantly can be combined with conventional histological procedures. Furthermore, it permits volumetric measurements as we show for the assessment of the plaque volumes in the aortic valve region of mice from an ApoE-/- mouse model. Subsequent, Masson-Goldner trichrome staining of paraffin sections of PTA stained samples revealed intact collagen and muscle fibres and positive staining of CD31 on endothelial cells by immunohistochemistry illustrates that our approach does not prevent immunochemistry analysis. The feasibility to scan hearts already embedded in paraffin ensured a 100% correlation between virtual cut sections of the CT data sets and histological heart sections of the same sample and may allow in future guiding the cutting process to specific regions of interest. In summary, since our CT based virtual histology approach is a powerful tool for the 3D depiction of morphological alterations in hearts and embryos in high resolution and can be combined with classical histological analysis it may be used in preclinical research to unravel structural alterations of various heart diseases. PMID:28178293

  2. Comparative Evaluation of Stress Distribution in Experimentally Designed Nickel-titanium Rotary Files with Varying Cross Sections: A Finite Element Analysis.

    PubMed

    Basheer Ahamed, Shadir Bughari; Vanajassun, Purushothaman Pranav; Rajkumar, Kothandaraman; Mahalaxmi, Sekar

    2018-04-01

    Single cross-sectional nickel-titanium (NiTi) rotary instruments during continuous rotations are subjected to constant and variable stresses depending on the canal anatomy. This study was intended to create 2 new experimental, theoretic single-file designs with combinations of triple U (TU), triangle (TR), and convex triangle (CT) cross sections and to compare their bending stresses in simulated root canals with a single cross-sectional instrument using finite element analysis. A 3-dimensional model of the simulated root canal with 45° curvature and NiTi files with 5 cross-sectional designs were created using Pro/ENGINEER Wildfire 4.0 software (PTC Inc, Needham, MA) and ANSYS software (version 17; ANSYS, Inc, Canonsburg, PA) for finite element analysis. The NiTi files of 3 groups had single cross-sectional shapes of CT, TR, and TU designs, and 2 experimental groups had a CT, TR, and TU (CTU) design and a TU, TR, and CT (UTC) design. The file was rotated in simulated root canals to analyze the bending stress, and the von Mises stress value for every file was recorded in MPa. Statistical analysis was performed using the Kruskal-Wallis test and the Bonferroni-adjusted Mann-Whitney test for multiple pair-wise comparison with a P value <.05 (95 %). The maximum bending stress of the rotary file was observed in the apical third of the CT design, whereas comparatively less stress was recorded in the CTU design. The TU and TR designs showed a similar stress pattern at the curvature, whereas the UTC design showed greater stress in the apical and middle thirds of the file in curved canals. All the file designs showed a statistically significant difference. The CTU designed instruments showed the least bending stress on a 45° angulated simulated root canal when compared with all the other tested designs. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. TU-F-CAMPUS-I-04: A Novel Phantom to Evaluate Longitudinal and Angular Automatic Tube Current Modulation (ATCM) in CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merzan, D; Bujila, R; Nowik, P

    Purpose: To manufacture a phantom specifically designed for the purpose of evaluating the performance of the longitudinal and angular automatic tube current modulation (ATCM) on modern CT scanners. Methods: In order to evaluate angular ATCM, the phantom has an elliptical cross section (aspect ratio 3:2). To evaluate longitudinal ATCM, the phantom consists of 3 sections, with different major axes (25 cm, 30 cm and 35 cm). Each section is 15 cm long in the longitudinal direction. Between each section is a smooth transition. The phantom was milled from a solid block of PMMA. ATCM performance is evaluated by 1) analyzingmore » the applied tube current for each slice of the phantom and 2) analyzing the distribution of image noise (σ) along the scan direction at different positions in the phantom. A demonstration of the ATCM performance evaluation is given by investigating the effects of miscentering during a CT scan. Results: The developed phantom has proven useful for evaluating both the longitudinal and angular ATCM on modern CT scanners (spiral collimations ≥ 4 cm). Further benefits are the smooth transitions between the sections that prevent abnormal responses in the ATCM and the invariant sections that provide a means for investigating the stability of image noise. The homogeneity of the phantom makes image noise at different positions along the scan direction easy to quantify, which is crucial to understand how well the applied ATCM can produce a desired image quality. Conclusion: It is important to understand how the ATCM functions on CT scanners as it can directly affect dose and image quality. The phantom that has been developed is a most valuable tool to understand how different variables during a scan can affect the outcome of the longitudinal and angular ATCM.« less

  4. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    PubMed

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  5. BIVOUAC OF DEAD TABLET, “THE MUFFLED DRUM’S SAD ROLL HAS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    BIVOUAC OF DEAD TABLET, “THE MUFFLED DRUM’S SAD ROLL HAS BEAT,” SECTION 6. VIEW TO SOUTH. - Hot Springs National Cemetery, Virginia Medical Center 500 North Fifth Street, Hot Springs, Fall River County, SD

  6. BIVOUAC OF DEAD TABLET, “YOUR OWN PROUD LAND’S,” AND RETAINING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    BIVOUAC OF DEAD TABLET, “YOUR OWN PROUD LAND’S,” AND RETAINING WALLS, SECTION 3. VIEW TO EAST. - Hot Springs National Cemetery, Virginia Medical Center 500 North Fifth Street, Hot Springs, Fall River County, SD

  7. BIVOUAC OF DEAD TABLET, “NO VISION OF THE MORROW’S STRIFE,” ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    BIVOUAC OF DEAD TABLET, “NO VISION OF THE MORROW’S STRIFE,” SECTION 4. VIEW TO SOUTH. - Hot Springs National Cemetery, Virginia Medical Center 500 North Fifth Street, Hot Springs, Fall River County, SD

  8. Wordburn hot in-plant asphalt pavement recycling project : final report.

    DOT National Transportation Integrated Search

    1992-05-01

    In 1977, the Oregon Department of Transportation constructed a demonstration project using approximately 47,000 tons of stockpiled asphalt concrete (AC) material to overlay a section of pavement in Oregon. The stockpiled AC material was hot in-plant ...

  9. A&M. A&M building (TAN607). Camera facing east. From left to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. A&M building (TAN-607). Camera facing east. From left to right, pool section, hot shop, cold shop, and machine shop. Biparting doors to hot shop are in open position behind shroud. Four rail tracks lead to hot shop and cold shop. Date: August 20, 1954. INEEL negative no. 11706 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  10. Comparison of cross-sectional anatomy and computed tomography of the tarsus in horses.

    PubMed

    Raes, Els V; Bergman, Eric H J; van der Veen, Henk; Vanderperren, Katrien; Van der Vekens, Elke; Saunders, Jimmy H

    2011-09-01

    To compare computed tomography (CT) images of equine tarsi with cross-sectional anatomic slices and evaluate the potential of CT for imaging pathological tarsal changes in horses. 6 anatomically normal equine cadaveric hind limbs and 4 tarsi with pathological changes. Precontrast CT was performed on 3 equine tarsi; sagittal and dorsal reconstructions were made. In all limbs, postcontrast CT was performed after intra-articular contrast medium injection of the tarsocrural, centrodistal, and tarsometatarsal joints. Images were matched with corresponding anatomic slices. Four tarsi with pathological changes underwent CT examination. The tibia, talus, calcaneus, and central, fused first and second, third, and fourth tarsal bones were clearly visualized as well as the long digital extensor, superficial digital flexor, lateral digital flexor (with tarsal flexor retinaculum), gastrocnemius, peroneus tertius, and tibialis cranialis tendons and the long plantar ligament. The lateral digital extensor, medial digital flexor, split peroneus tertius, and tibialis cranialis tendons and collateral ligaments could be located but not always clearly identified. Some small tarsal ligaments were identifiable, including plantar, medial, interosseus, and lateral talocalcaneal ligaments; interosseus talocentral, centrodistal, and tarsometatarsal ligaments; proximal and distal plantar ligaments; and talometatarsal ligament. Parts of the articular cartilage could be assessed on postcontrast images. Lesions were detected in the 4 tarsi with pathological changes. CT of the tarsus is recommended when radiography and ultrasonography are inconclusive and during preoperative planning for treatment of complex fractures. Images from this study can serve as a CT reference, and CT of pathological changes was useful.

  11. Radiology reports for incidental thyroid nodules on CT and MRI: high variability across subspecialties.

    PubMed

    Grady, A T; Sosa, J A; Tanpitukpongse, T P; Choudhury, K R; Gupta, R T; Hoang, J K

    2015-02-01

    Variability in radiologists' reporting styles and recommendations for incidental thyroid nodules can lead to confusion among clinicians and may contribute to inconsistent patient care. Our aim was to describe reporting practices of radiologists for incidental thyroid nodules seen on CT and MR imaging and to determine factors that influence reporting styles. This is a retrospective study of patients with incidental thyroid nodules reported on CT and MR imaging between January and December 2011, identified by text search for "thyroid nodule" in all CT and MR imaging reports. The studies included CT and MR imaging scans of the neck, spine, and chest. Radiology reports were divided into those that mentioned the incidental thyroid nodules only in the "Findings" section versus those that reported the incidental thyroid nodules in the "Impression" section as well, because this latter reporting style gives more emphasis to the finding. Univariate and multivariate analyses were performed to identify radiologist, patient, and nodule characteristics that influenced reporting styles. Three hundred seventy-five patients met the criterion of having incidental thyroid nodules. One hundred thirty-eight (37%) patients had incidental thyroid nodules reported in the "Impression" section. On multivariate analysis, only radiologists' divisions and nodule size were associated with reporting in "Impression." Chest radiologists and neuroradiologists were more likely to report incidental thyroid nodules in the "Impression" section than their abdominal imaging colleagues, and larger incidental thyroid nodules were more likely to be reported in "Impression" (P ≤ .03). Seventy-three percent of patients with incidental thyroid nodules of ≥20 mm were reported in the "Impression" section, but higher variability in reporting was seen for incidental thyroid nodules measuring 10-14 mm and 15-19 mm, which were reported in "Impression" for 61% and 50% of patients, respectively. Reporting practices for incidental thyroid nodules detected on CT and MR imaging are predominantly influenced by nodule size and the radiologist's subspecialty. Reporting was highly variable for nodules measuring 10-19 mm; this finding can be partially attributed to different reporting styles among radiology subspecialty divisions. The variability demonstrated in this study further underscores the need to develop CT and MR imaging practice guidelines with the goal of standardizing reporting of incidental thyroid nodules and thereby potentially improving the consistency and quality of patient care. © 2015 by American Journal of Neuroradiology.

  12. Turbine Engine Hot Section Technology, 1984

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Presentations were made concerning the hot section environment and behavior of combustion liners, turbine blades, and waves. The presentations were divided into six sessions: instrumentation, combustion, turbine heat transfer, structural analysis, fatigue and fracture, and surface properties. The principal objective of each session was to disseminate research results to date, along with future plans. Topics discussed included modeling of thermal and fluid flow phenomena, structural analysis, fatigue and fracture, surface protective coatings, constitutive behavior, stress-strain response, and life prediction methods.

  13. Thin Film Ceramic Strain Sensor Development for High Temperature Environments

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D.; Fralick, Gustave C.; Gonzalez, Jose M.; Laster, Kimala L.

    2008-01-01

    The need for sensors to operate in harsh environments is illustrated by the need for measurements in the turbine engine hot section. The degradation and damage that develops over time in hot section components can lead to catastrophic failure. At present, the degradation processes that occur in the harsh hot section environment are poorly characterized, which hinders development of more durable components, and since it is so difficult to model turbine blade temperatures, strains, etc, actual measurements are needed. The need to consider ceramic sensing elements is brought about by the temperature limits of metal thin film sensors in harsh environments. The effort at the NASA Glenn Research Center (GRC) to develop high temperature thin film ceramic static strain gauges for application in turbine engines is described, first in the fan and compressor modules, and then in the hot section. The near-term goal of this research effort was to identify candidate thin film ceramic sensor materials and provide a list of possible thin film ceramic sensor materials and corresponding properties to test for viability. A thorough literature search was conducted for ceramics that have the potential for application as high temperature thin film strain gauges chemically and physically compatible with the NASA GRCs microfabrication procedures and substrate materials. Test results are given for tantalum, titanium and zirconium-based nitride and oxynitride ceramic films.

  14. Comparing SUV values of images at PET-CT console and the RT planning console using identical dataset of a study phantom.

    PubMed

    Munshi, Anusheel; Paul, Sayan; Sarkar, Biplab; Bala, Pinkey; Ganesh, Tharmar; Sen, Ishita B; Pant, Vineet; Mohanti, Bidhu K

    2016-01-01

    The use of positron emission tomography (PET) for radiotherapy planning purposes has become increasingly important in the last few years.In the current study, we compared the SUV values of images at the PET CT console to the SUV values obtained at the RT planning workstation. The PET-CT cylindrical body phantom was filled with a uniform 18F solution of 5.3. ± 0.27 kBq/mL radioactivity concentration. PET-CT scans were performed on a16 slice Time of Flight system. On a single day, the three consecutive scans were done at three time points 15 minutes apart to generate time points image data sets titled T1, T2, and T3. SUV calculations were performed by drawing region of interest. (ROI) encompassing the entire hot spot on each slice on the PET-CT console and the iPlan workstation. Minimum SUV, Maximum SUV and the Mean SUV were recorded. Statistical analysis was done using the SPSS software. (SPSS Inc.) (Version 18). The absolute difference in average max SUV values i.e. Max (PET-CT) - Max (iPlan) for the time points T1, T2 and T3 were -0.168 (SD 0.175), -0.172 (SD 0.172) and -0.178 (SD 0.169). The difference in the minimum SUV values were -0.513 (SD 0.428), -0.311 (SD 0.358) and -0.303 (SD 0.322), respectively. Finally, the difference in the mean SUV values were -0.107 (SD 0.040), -0.096 (SD 0.067) and -0.072 (SD 0.044), respectively. Our study found out that the average difference in the two systems for maximum SUV values was < 0.2 absolute units.Our study suggests good reproducibility of SUV between the two systems. The relevance of these findings would be of seminal importance in current and future SUV-based PET-CT-based contouring in treatment planning systems.

  15. A comparison of hepatic segmental anatomy as revealed by cross-sections and MPR CT imaging.

    PubMed

    Liu, Xue-Jing; Zhang, Jian-Fei; Sui, Hong-Jin; Yu, Sheng-Bo; Gong, Jin; Liu, Jie; Wu, Le-Bin; Liu, Cheng; Bai, Jian; Shi, Bing-Yi

    2013-05-01

    To compare the areas of human liver horizontal sections with computed tomography (CT) images and to evaluate whether the subsegments determined by CT are consistent with the actual anatomy. Six human cadaver livers were made into horizontal slices with multislice spiral CT three-dimensional (3D) reconstruction was used during infusion process. Each liver segment was displayed using different color, and 3D images of the portal and hepatic vein were reconstructed. Each segmental area was measured on CT-reconstructed images, which were compared with the actual area on the sections of the same liver. The measurements were performed at four key levels namely: (1) the three hepatic veins, (2) the left, and (3) the right branch of portal vein (PV), and (4) caudal to the bifurcation of the PV. By dividing the sum of these areas by the total area of the liver, the authors got the percentage of the incorrectly determined subsegmental areas. In addition to these percentage values, the maximum distances of the radiologically determined intersegmental boundaries from the true anatomic boundaries were measured. On the four key levels, an average of 28.64 ± 10.26% of the hepatic area of CT images was attributed to an incorrect segment. The mean-maximum error between artificial segments on images and actual anatomical segments was 3.81 ± 1.37 cm. The correlation between radiological segmenting method and actual anatomy was poor. The hepatic segments being divided strictly according to the branching point of the PV could be more informative during liver segmental resection. Copyright © 2012 Wiley Periodicals, Inc.

  16. Turbine system

    DOEpatents

    McMahan, Kevin Weston; Dillard, Daniel Jackson

    2016-05-03

    A turbine system is disclosed. The turbine system includes a transition duct having an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The turbine system further includes a turbine section connected to the transition duct. The turbine section includes a plurality of shroud blocks at least partially defining a hot gas path, a plurality of buckets at least partially disposed in the hot gas path, and a plurality of nozzles at least partially disposed in the hot gas path. At least one of a shroud block, a bucket, or a nozzle includes means for withstanding high temperatures.

  17. Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions

    NASA Astrophysics Data System (ADS)

    Schneider, Wilfried; Bortfeld, Thomas; Schlegel, Wolfgang

    2000-02-01

    We describe a new method to convert CT numbers into mass density and elemental weights of tissues required as input for dose calculations with Monte Carlo codes such as EGS4. As a first step, we calculate the CT numbers for 71 human tissues. To reduce the effort for the necessary fits of the CT numbers to mass density and elemental weights, we establish four sections on the CT number scale, each confined by selected tissues. Within each section, the mass density and elemental weights of the selected tissues are interpolated. For this purpose, functional relationships between the CT number and each of the tissue parameters, valid for media which are composed of only two components in varying proportions, are derived. Compared with conventional data fits, no loss of accuracy is accepted when using the interpolation functions. Assuming plausible values for the deviations of calculated and measured CT numbers, the mass density can be determined with an accuracy better than 0.04 g cm-3 . The weights of phosphorus and calcium can be determined with maximum uncertainties of 1 or 2.3 percentage points (pp) respectively. Similar values can be achieved for hydrogen (0.8 pp) and nitrogen (3 pp). For carbon and oxygen weights, errors up to 14 pp can occur. The influence of the elemental weights on the results of Monte Carlo dose calculations is investigated and discussed.

  18. High Temperature Chemistry at NASA: Hot Topics

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.

    2014-01-01

    High Temperature issues in aircraft engines Hot section: Ni and Co based Superalloys Oxidation and Corrosion (Durability) at high temperatures. Thermal protection system (TPS) and RCC (Reinforced Carbon-Carbon) on the Space Shuttle Orbiter. High temperatures in other worlds: Planets close to their stars.

  19. METAL RECOVERY/REMOVAL USING NON-ELECTROLYTIC METAL RECOVERY

    EPA Science Inventory

    Radiator repair shops most commonly use hot caustic solutions to clean radiator sections prior to resoldering. he hot caustic, or "boil-out" solutions as they are cabled in the trade, become contaminated with dirt, rust flakes, paint flakes and miscellaneous particulate debris. n...

  20. Steel slag in hot mix asphalt concrete : final report

    DOT National Transportation Integrated Search

    2000-04-01

    In September 1994, steel slag test and control sections were constructed in Oregon to evaluate the use of steel slag in hot mix asphalt concrete (HMAC). This report covers the construction and five-year performance of a pavement constructed with 30% ...

  1. Reactivating Catalytic Surface: Insights into the Role of Hot Holes in Plasmonic Catalysis.

    PubMed

    Peng, Tianhuan; Miao, Junjian; Gao, Zhaoshuai; Zhang, Linjuan; Gao, Yi; Fan, Chunhai; Li, Di

    2018-03-01

    Surface plasmon resonance of coinage metal nanoparticles is extensively exploited to promote catalytic reactions via harvesting solar energy. Previous efforts on elucidating the mechanisms of enhanced catalysis are devoted to hot electron-induced photothermal conversion and direct charge transfer to the adsorbed reactants. However, little attention is paid to roles of hot holes that are generated concomitantly with hot electrons. In this work, 13 nm spherical Au nanoparticles with small absorption cross-section are employed to catalyze a well-studied glucose oxidation reaction. Density functional theory calculation and X-ray absorption spectrum analysis reveal that hot holes energetically favor transferring catalytic intermediates to product molecules and then desorbing from the surface of plasmonic catalysts, resulting in the recovery of their catalytic activities. The studies shed new light on the use of the synergy of hot holes and hot electrons for plasmon-promoted catalysis. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Dependence of Coronary 3-Dimensional Dose Maps on Coronary Topologies and Beam Set in Breast Radiation Therapy: A Study Based on CT Angiographies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moignier, Alexandra, E-mail: alexandra.moignier@gmail.com; Broggio, David; Derreumaux, Sylvie

    2014-05-01

    Purpose: In left-side breast radiation therapy (RT), doses to the left main (LM) and left anterior descending (LAD) coronary arteries are usually assessed after delineation by prior anatomic knowledge on the treatment planning computed tomography (CT) scan. In this study, dose sensitivity due to interindividual coronary topology variation was assessed, and hot spots were located. Methods and Materials: Twenty-two detailed heart models, created from heart computed tomography angiographies, were fitted into a single representative female thorax. Two breast RT protocols were then simulated into a treatment planning system: the first protocol comprised tangential and tumoral bed beams (TGs{sub T}B) atmore » 50 + 16 Gy, the second protocol added internal mammary chain beams at 50 Gy to TGs{sub T}B (TGs{sub T}B{sub I}MC). For the heart, the LAD, and the LM, several dose indicators were calculated: dose-volume histograms, mean dose (D{sub mean}), minimal dose received by the most irradiated 2% of the volume (D{sub 2%}), and 3-dimensional (3D) dose maps. Variations of these indicators with anatomies were studied. Results: For the LM, the intermodel dispersion of D{sub mean} and D{sub 2%} was 10% and 11%, respectively, with TGs{sub T}B and 40% and 80%, respectively, with TGs{sub T}B{sub I}MC. For the LAD, these dispersions were 19% (D{sub mean}) and 49% (D{sub 2%}) with TGs{sub T}B and 35% (D{sub mean}) and 76% (D{sub 2%}) with TGs{sub T}B{sub I}MC. The 3D dose maps revealed that the internal mammary chain beams induced hot spots between 20 and 30 Gy on the LM and the proximal LAD for some coronary topologies. Without IMC beams, hot spots between 5 and 26 Gy are located on the middle and distal LAD. Conclusions: Coronary dose distributions with hot spot location and dose level can change significantly depending on coronary topology, as highlighted by 3D coronary dose maps. In clinical practice, coronary imaging may be required for a relevant coronary dose assessment, especially in cases of internal mammary chain irradiation.« less

  3. Characterization of a wind turbine model for wake aerodynamics studies

    NASA Astrophysics Data System (ADS)

    Cuzzola, Francesco; Aubrun, Sandrine; Leitl, Bernd

    2014-12-01

    A model wind turbine has been designed at the University of Hamburg within the scope of the FP7 fundend project WAUDIT. The purpose of the experiment described in this paper is to characterize the performances of two rotors by means of measuring the thrust coefficient Ct. Ct is a similarity parameter for the wake and is thought to be the most effective one. Its value has been directly measured using a force balance and indirectly calculated from the velocity profiles measured three diameters downstream of the rotor with hot wire anemometry. Results show that, in order to reproduce the wake behaviour, the matching of the Ct, which is a quantitative achievement, has to be integrated with measurements such as velocity profiles in the wake. In fact the velocity deficit illustrates the mechanism of transforming the axial momentum into torque assuring qualitatively the proper reproduction of the wake. This latter information assures that the achievement of a certain thrust force acting on the rotor is due to its performances in transforming the axial momentum into torque and not an effect of other phenomena such as a stall at the blades.

  4. CT artifact recognition for the nuclear technologist.

    PubMed

    Popilock, Robert; Sandrasagaren, Kumar; Harris, Lowell; Kaser, Keith A

    2008-06-01

    The goal of this article is to make the PET/CT and SPECT/CT operator aware of common artifacts found in CT. In diagnostic imaging, the ability to render an accurate diagnosis requires the technologist to take steps to optimize image quality and recognize when image quality has been compromised-that is, when there is an image artifact. One way these artifacts occur is through the inability of the CT linear attenuation image to precisely represent the linear attenuation map of a 2-dimensional section through the body. The reasons for this inability are multifold. First, CT is subject to the laws of x-ray quantum physics resulting in noise in all CT images. Moreover, all current CT x-ray systems generate a spectrum of energies. Also, CT scanners use detectors of finite dimension, as are the x-ray focal spots; reconstruct images from a finite number of samples distributed over a finite number of views; and acquire the data for each reconstruction over a finite period.

  5. Geologic Map of the Neal Hot Springs Geothermal Area - GIS Data

    DOE Data Explorer

    Faulds, James E.

    2013-03-31

    Neal Hot Springs—ESRI Geodatabase (ArcGeology v1.3): - Contains all the geologic map data, including faults, contacts, folds, unit polygons, and attitudes of strata and faults. - List of stratigraphic units and stratigraphic correlation diagram. - Three cross‐sections. - Locations of production, injection, and exploration wells. - Locations of 40Ar/39Ar samples. - Location of XRF geochemical samples. - 3D model constructed with EarthVision using geologic map data, cross‐sections, drill‐hole data, and geophysics (model not in the ESRI geodatabase).

  6. Summary of experimental heat-transfer results from the turbine hot section facility

    NASA Technical Reports Server (NTRS)

    Gladden, Herbert J.; Yeh, Fredrick C.

    1993-01-01

    Experimental data from the turbine Hot Section Facility are presented and discussed. These data include full-coverage film-cooled airfoil results as well as special instrumentation results obtained at simulated real engine conditions. Local measurements of airfoil wall temperature, airfoil gas-path static-pressure distribution, and local heat-transfer coefficient distributions are presented and discussed. In addition, measured gas and coolant temperatures and pressures are presented. These data are also compared with analyses from Euler and boundary-layer codes.

  7. Component-specific modeling. [jet engine hot section components

    NASA Technical Reports Server (NTRS)

    Mcknight, R. L.; Maffeo, R. J.; Tipton, M. T.; Weber, G.

    1992-01-01

    Accomplishments are described for a 3 year program to develop methodology for component-specific modeling of aircraft hot section components (turbine blades, turbine vanes, and burner liners). These accomplishments include: (1) engine thermodynamic and mission models, (2) geometry model generators, (3) remeshing, (4) specialty three-dimensional inelastic structural analysis, (5) computationally efficient solvers, (6) adaptive solution strategies, (7) engine performance parameters/component response variables decomposition and synthesis, (8) integrated software architecture and development, and (9) validation cases for software developed.

  8. Comparative performance of rubber modified hot mix asphalt under ALF loading.

    DOT National Transportation Integrated Search

    2003-08-01

    Experiment 2 at the Louisiana ALF site involved determining the engineering benefits of using powdered rubber (PRM) in hot mix asphalt mixes. Three full scale test sections were constructed and subjected to increasing loads from the ALF. Lane 2-1 inc...

  9. 7 CFR 305.22 - Hot water immersion treatment schedules.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Hot water immersion treatment schedules. 305.22 Section 305.22 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS Heat Treatments § 305.22...

  10. NORTH PORTAL-HOT WATER CIRCULATION PUMP CALCULATION-SHOP BUILDING #5006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. Blackstone

    1996-01-25

    The purpose of this design analysis and calculation is to size a circulating pump for the service hot water system in the Shop Building 5006, in accordance with the Uniform Plumbing Code (Section 4.4.1) and U.S. Department of Energy Order 6430.1A-1540 (Section 4.4.2). The method used for the calculation is based on Reference 5.2. This consists of determining the total heat transfer from the service hot water system piping to the surrounding environment. The heat transfer is then used to define the total pumping capacity based on a given temperature change in the circulating hot water as it flows throughmore » the closed loop piping system. The total pumping capacity is used to select a pump model from manufacturer's literature. This established the head generation for that capacity and particular pump model. The total length of all hot water supply and return piping including fittings is then estimated from the plumbing drawings which defines the pipe friction losses that must fit within the available pump head. Several iterations may be required before a pump can be selected that satisfies the head-capacity requirements.« less

  11. Vehicle cabin cooling system for capturing and exhausting heated boundary layer air from inner surfaces of solar heated windows

    DOEpatents

    Farrington, Robert B.; Anderson, Ren

    2001-01-01

    The cabin cooling system includes a cooling duct positioned proximate and above upper edges of one or more windows of a vehicle to exhaust hot air as the air is heated by inner surfaces of the windows and forms thin boundary layers of heated air adjacent the heated windows. The cabin cooling system includes at least one fan to draw the hot air into the cooling duct at a flow rate that captures the hot air in the boundary layer without capturing a significant portion of the cooler cabin interior air and to discharge the hot air at a point outside the vehicle cabin, such as the vehicle trunk. In a preferred embodiment, the cooling duct has a cross-sectional area that gradually increases from a distal point to a proximal point to the fan inlet to develop a substantially uniform pressure drop along the length of the cooling duct. Correspondingly, this cross-sectional configuration develops a uniform suction pressure and uniform flow rate at the upper edge of the window to capture the hot air in the boundary layer adjacent each window.

  12. Automated assessment of breast tissue density in non-contrast 3D CT images without image segmentation based on a deep CNN

    NASA Astrophysics Data System (ADS)

    Zhou, Xiangrong; Kano, Takuya; Koyasu, Hiromi; Li, Shuo; Zhou, Xinxin; Hara, Takeshi; Matsuo, Masayuki; Fujita, Hiroshi

    2017-03-01

    This paper describes a novel approach for the automatic assessment of breast density in non-contrast three-dimensional computed tomography (3D CT) images. The proposed approach trains and uses a deep convolutional neural network (CNN) from scratch to classify breast tissue density directly from CT images without segmenting the anatomical structures, which creates a bottleneck in conventional approaches. Our scheme determines breast density in a 3D breast region by decomposing the 3D region into several radial 2D-sections from the nipple, and measuring the distribution of breast tissue densities on each 2D section from different orientations. The whole scheme is designed as a compact network without the need for post-processing and provides high robustness and computational efficiency in clinical settings. We applied this scheme to a dataset of 463 non-contrast CT scans obtained from 30- to 45-year-old-women in Japan. The density of breast tissue in each CT scan was assigned to one of four categories (glandular tissue within the breast <25%, 25%-50%, 50%-75%, and >75%) by a radiologist as ground truth. We used 405 CT scans for training a deep CNN and the remaining 58 CT scans for testing the performance. The experimental results demonstrated that the findings of the proposed approach and those of the radiologist were the same in 72% of the CT scans among the training samples and 76% among the testing samples. These results demonstrate the potential use of deep CNN for assessing breast tissue density in non-contrast 3D CT images.

  13. Magnetic resonance imaging, computed tomography, and gross anatomy of the canine tarsus.

    PubMed

    Deruddere, Kirsten J; Milne, Marjorie E; Wilson, Kane M; Snelling, Sam R

    2014-11-01

    To describe the normal anatomy of the soft tissues of the canine tarsus as identified on computed tomography (CT) and magnetic resonance imaging (MRI) and to evaluate specific MRI sequences and planes for observing structures of diagnostic interest. Prospective descriptive study. Canine cadavers (n = 3). A frozen cadaver pelvic limb was used to trial multiple MRI sequences using a 1.5 T superconducting magnet and preferred sequences were selected. Radiographs of 6 canine cadaver pelvic limbs confirmed the tarsi were radiographically normal. A 16-slice CT scanner was used to obtain 1 mm contiguous slices through the tarsi. T1-weighted, proton density with fat suppression (PD FS) and T2-weighted MRI sequences were obtained in the sagittal plane, T1-weighted, and PD FS sequences in the dorsal plane and PD FS sequences in the transverse plane. The limbs were frozen for one month and sliced into 4-5 mm thick frozen sections. Anatomic sections were photographed and visually correlated to CT and MR images. Most soft tissue structures were easiest to identify on the transverse MRI sections with cross reference to either the sagittal or dorsal plane. Bony structures were easily identified on all CT, MR, and gross sections. The anatomy of the canine tarsus can be readily identified on MR imaging. © Copyright 2014 by The American College of Veterinary Surgeons.

  14. Added Value of Coronal Reformations for Duty Radiologists and for Referring Physicians or Surgeons in the CT Diagnosis of Acute Appendicitis

    PubMed Central

    Lee, Kyoung Ho; Hahn, Seokyung; Lee, Kyung Won; Lee, Hak Jong; Kim, Tae Jung; Kang, Sung-Bum; Shin, Joong Ho; Park, Byung Joo

    2006-01-01

    Objective To assess the added value of coronal reformation for radiologists and for referring physicians or surgeons in the CT diagnosis of acute appendicitis. Materials and Methods Contrast-enhanced CT was performed using 16-detector-row scanners in 110 patients, 46 of whom had appendicitis. Transverse (5-mm thickness, 4-mm increment), coronal (5-mm thickness, 4-mm increment), and combined transverse and coronal sections were interpreted by four radiologists, two surgeons and two emergency physicians. The area under the receiver operating characteristic curve (Az value), sensitivity, specificity (McNemar test), diagnostic confidence and appendiceal visualization (Wilcoxon signed rank test) were compared. Results For radiologists, the additional coronal sections tended to increase the Az value (0.972 vs. 0.986, p = 0.076) and pooled sensitivity (92% [95% CI: 88, 96] vs. 96% [93, 99]), and enhanced appendiceal visualization in true-positive cases (p = 0.031). For non-radiologists, no such enhancement was observed, and the confidence for excluding acute appendicitis declined (p = 0.013). Coronal sections alone were inferior to transverse sections for diagnostic confidence as well as appendiceal visualization for each reader group studied (p < 0.05). Conclusion The added value of coronal reformation is more apparent for radiologists compared to referring physicians or surgeons in the CT diagnosis of acute appendicitis. PMID:16799269

  15. Multimaterial Decomposition Algorithm for the Quantification of Liver Fat Content by Using Fast-Kilovolt-Peak Switching Dual-Energy CT: Experimental Validation.

    PubMed

    Hyodo, Tomoko; Hori, Masatoshi; Lamb, Peter; Sasaki, Kosuke; Wakayama, Tetsuya; Chiba, Yasutaka; Mochizuki, Teruhito; Murakami, Takamichi

    2017-02-01

    Purpose To assess the ability of fast-kilovolt-peak switching dual-energy computed tomography (CT) by using the multimaterial decomposition (MMD) algorithm to quantify liver fat. Materials and Methods Fifteen syringes that contained various proportions of swine liver obtained from an abattoir, lard in food products, and iron (saccharated ferric oxide) were prepared. Approval of this study by the animal care and use committee was not required. Solid cylindrical phantoms that consisted of a polyurethane epoxy resin 20 and 30 cm in diameter that held the syringes were scanned with dual- and single-energy 64-section multidetector CT. CT attenuation on single-energy CT images (in Hounsfield units) and MMD-derived fat volume fraction (FVF; dual-energy CT FVF) were obtained for each syringe, as were magnetic resonance (MR) spectroscopy measurements by using a 1.5-T imager (fat fraction [FF] of MR spectroscopy). Reference values of FVF (FVF ref ) were determined by using the Soxhlet method. Iron concentrations were determined by inductively coupled plasma optical emission spectroscopy and divided into three ranges (0 mg per 100 g, 48.1-55.9 mg per 100 g, and 92.6-103.0 mg per 100 g). Statistical analysis included Spearman rank correlation and analysis of covariance. Results Both dual-energy CT FVF (ρ = 0.97; P < .001) and CT attenuation on single-energy CT images (ρ = -0.97; P < .001) correlated significantly with FVF ref for phantoms without iron. Phantom size had a significant effect on dual-energy CT FVF after controlling for FVF ref (P < .001). The regression slopes for CT attenuation on single-energy CT images in 20- and 30-cm-diameter phantoms differed significantly (P = .015). In sections with higher iron concentrations, the linear coefficients of dual-energy CT FVF decreased and those of MR spectroscopy FF increased (P < .001). Conclusion Dual-energy CT FVF allows for direct quantification of fat content in units of volume percent. Dual-energy CT FVF was larger in 30-cm than in 20-cm phantoms, though the effect of object size on fat estimation was less than that of CT attenuation on single-energy CT images. In the presence of iron, dual-energy CT FVF led to underestimateion of FVF ref to a lesser degree than FF of MR spectroscopy led to overestimation of FVF ref . © RSNA, 2016 Online supplemental material is available for this article.

  16. SU-E-CAMPUS-I-06: Y90 PET/CT for the Instantaneous Determination of Both Target and Non-Target Absorbed Doses Following Hepatic Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pasciak, A; Kao, J

    2014-06-15

    Purpose The process of converting Yttrium-90 (Y90) PET/CT images into 3D absorbed dose maps will be explained. The simple methods presented will allow the medical physicst to analyze Y90 PET images following radioembolization and determine the absorbed dose to tumor, normal liver parenchyma and other areas of interest, without application of Monte-Carlo radiation transport or dose-point-kernel (DPK) convolution. Methods Absorbed dose can be computed from Y90 PET/CT images based on the premise that radioembolization is a permanent implant with a constant relative activity distribution after infusion. Many Y90 PET/CT publications have used DPK convolution to obtain 3D absorbed dose maps.more » However, this method requires specialized software limiting clinical utility. The Local Deposition method, an alternative to DPK convolution, can be used to obtain absorbed dose and requires no additional computer processing. Pixel values from regions of interest drawn on Y90 PET/CT images can be converted to absorbed dose (Gy) by multiplication with a scalar constant. Results There is evidence that suggests the Local Deposition method may actually be more accurate than DPK convolution and it has been successfully used in a recent Y90 PET/CT publication. We have analytically compared dose-volume-histograms (DVH) for phantom hot-spheres to determine the difference between the DPK and Local Deposition methods, as a function of PET scanner point-spread-function for Y90. We have found that for PET/CT systems with a FWHM greater than 3.0 mm when imaging Y90, the Local Deposition Method provides a more accurate representation of DVH, regardless of target size than DPK convolution. Conclusion Using the Local Deposition Method, post-radioembolization Y90 PET/CT images can be transformed into 3D absorbed dose maps of the liver. An interventional radiologist or a Medical Physicist can perform this transformation in a clinical setting, allowing for rapid prediction of treatment efficacy by comparison to published tumoricidal thresholds.« less

  17. Micro-CT evaluation and histological analysis of screw-bone interface of expansive pedicle screw in osteoporotic sheep.

    PubMed

    Wan, Shi-yong; Lei, Wei; Wu, Zi-xiang; Lv, Rong; Wang, Jun; Fu, Suo-chao; Li, Bo; Zhan, Ce

    2008-04-01

    To investigate the properties of screw-bone interface of expansive pedicle screw (EPS) in osteoporotic sheep by micro-CT and histological observation. Six female sheep with bilateral ovariectomy-induced osteoporosis were employed in this experiment. After EPS insertion in each femoral condyle, the sheep were randomly divided into two groups: 3 sheep were bred for 3 months (Group A), while the other 3 were bred for 6 months (Group B). After the animals being killed, the femoral condyles with EPS were obtained, which were three-dimensionally-imaged and reconstructed by micro-CT. Histological evaluation was made thereafter. The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section, especially within the spiral marking. In the non-expansive section, however, there was no significant difference between the interface and the distant parts. The regions of interest (ROI) adjacent to EPS were reconstructed and analyzed by micro-CT with the same thresholds. The three-dimensional (3-D) parameters, including tissue mineral density (TMD), bone volume fraction (BVF, BV/TV), bone surface/bone volume (BS/BV) ratio, trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp), were significantly better in expansive sections than non-expansive sections (P less than 0.05). Histologically, newly-formed bony trabeculae crawled along the expansive fissures and into the center of EPS. The newly-formed bones, as well as the bones at the bone-screw interface, closely contacted with the EPS and constructed four compartments. The findings of the current study, based on micro-CT and histological evaluation, suggest that EPS can significantly provide stabilization in osteoporotic cancellous bones.

  18. Hot mix asphalt research investigation for Connecticut : part E - comparison of field performance of superpave and traditional marshall mixes.

    DOT National Transportation Integrated Search

    2014-07-01

    This research is part of the series of investigated topics surrounding hot mix asphalt in Connecticut. : This research investigates the performance of sections of pavements designed using both the Marshall : and Superpave mix design methods. Sixteen ...

  19. 16 CFR 1505.51 - Hot surfaces.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Hot surfaces. 1505.51 Section 1505.51 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS... into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...

  20. Deep learning of the sectional appearances of 3D CT images for anatomical structure segmentation based on an FCN voting method.

    PubMed

    Zhou, Xiangrong; Takayama, Ryosuke; Wang, Song; Hara, Takeshi; Fujita, Hiroshi

    2017-10-01

    We propose a single network trained by pixel-to-label deep learning to address the general issue of automatic multiple organ segmentation in three-dimensional (3D) computed tomography (CT) images. Our method can be described as a voxel-wise multiple-class classification scheme for automatically assigning labels to each pixel/voxel in a 2D/3D CT image. We simplify the segmentation algorithms of anatomical structures (including multiple organs) in a CT image (generally in 3D) to a majority voting scheme over the semantic segmentation of multiple 2D slices drawn from different viewpoints with redundancy. The proposed method inherits the spirit of fully convolutional networks (FCNs) that consist of "convolution" and "deconvolution" layers for 2D semantic image segmentation, and expands the core structure with 3D-2D-3D transformations to adapt to 3D CT image segmentation. All parameters in the proposed network are trained pixel-to-label from a small number of CT cases with human annotations as the ground truth. The proposed network naturally fulfills the requirements of multiple organ segmentations in CT cases of different sizes that cover arbitrary scan regions without any adjustment. The proposed network was trained and validated using the simultaneous segmentation of 19 anatomical structures in the human torso, including 17 major organs and two special regions (lumen and content inside of stomach). Some of these structures have never been reported in previous research on CT segmentation. A database consisting of 240 (95% for training and 5% for testing) 3D CT scans, together with their manually annotated ground-truth segmentations, was used in our experiments. The results show that the 19 structures of interest were segmented with acceptable accuracy (88.1% and 87.9% voxels in the training and testing datasets, respectively, were labeled correctly) against the ground truth. We propose a single network based on pixel-to-label deep learning to address the challenging issue of anatomical structure segmentation in 3D CT cases. The novelty of this work is the policy of deep learning of the different 2D sectional appearances of 3D anatomical structures for CT cases and the majority voting of the 3D segmentation results from multiple crossed 2D sections to achieve availability and reliability with better efficiency, generality, and flexibility than conventional segmentation methods, which must be guided by human expertise. © 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  1. 40 CFR 93.109 - Criteria and procedures for determining conformity of transportation plans, programs, and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) through (k) of this section explain when the budget, interim emissions, and hot-spot tests are required... § 93.115 Project from a conforming plan and TIP § 93.116 CO, PM10, and PM2.5 hot-spots. § 93.117 PM10... Currently conforming plan and TIP § 93.116 CO, PM10, and PM2.5 hot-spots. § 93.117 PM10 and PM2.5 control...

  2. 40 CFR 93.109 - Criteria and procedures for determining conformity of transportation plans, programs, and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) through (k) of this section explain when the budget, interim emissions, and hot-spot tests are required... § 93.115 Project from a conforming plan and TIP § 93.116 CO, PM10, and PM2.5 hot-spots. § 93.117 PM10... Currently conforming plan and TIP § 93.116 CO, PM10, and PM2.5 hot-spots. § 93.117 PM10 and PM2.5 control...

  3. Diagnostic imaging in ophthalmology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, C.F.; Becker, M.H.; Flanagan, J.C.

    There are three sections in the book. The first section is a discussion of imaging techniques, which includes plain film radiography and multidirectional tomography of the orbit, computed tomography (CT) of the orbit and its use in the evaluation of ocular motility disorders, ultrasonography of the eye and orbit, investigation of the orbit by contrast techniques (which includes a brief review of angiography), the lachrimal drainage system, foreign body localization, and magnetic resonance imaging of the eye and orbit. There is extensive discussion of CT throughout the book. The second section is devoted to the role of these imaging methodsmore » in the evaluation of ophthalmic disorders. A discussion of congenital anomalies is useful for those centers that are exposed to unusual congenital anomalies and syndromes. Also included is evaluation of exophthalmous and thyroid ophthamalopathy, orbital tumors, lesions involving the visual pathways, CT assessment of paraorbital pathology (including basal and squamous cell tumors of the face), infection of the orbit, and orbital trauma. The third section is an overview of radiation therapy and malignant intraoccular tumors.« less

  4. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Zeniya, T.; Takeda, T.; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T.

    2001-07-01

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  5. Three-dimensional surface reconstruction for industrial computed tomography

    NASA Technical Reports Server (NTRS)

    Vannier, M. W.; Knapp, R. H.; Gayou, D. E.; Sammon, N. P.; Butterfield, R. L.; Larson, J. W.

    1985-01-01

    Modern high resolution medical computed tomography (CT) scanners can produce geometrically accurate sectional images of many types of industrial objects. Computer software has been developed to convert serial CT scans into a three-dimensional surface form, suitable for display on the scanner itself. This software, originally developed for imaging the skull, has been adapted for application to industrial CT scanning, where serial CT scans thrrough an object of interest may be reconstructed to demonstrate spatial relationships in three dimensions that cannot be easily understood using the original slices. The methods of three-dimensional reconstruction and solid modeling are reviewed, and reconstruction in three dimensions from CT scans through familiar objects is demonstrated.

  6. Hot wire in low Reynolds number flow

    NASA Technical Reports Server (NTRS)

    Kolb, M. A.; Covert, E. E.

    1984-01-01

    Progress reports were issued on the following experiments: (1) low Reynolds number flow phenomenon of periodic vortex shedding in the wake behind a cylinder as studied by applying the hot wire anemometer technique of flow measurement. The downstream diffusion of these shed vortices was of prime concern. An evaluation of the performance of the hot wire at low Reynolds number is also considered. (2) A brief examination of the back sections of the Wright Brothers wind tunnel circuits were conducted to establish whether or not gross flow deviations were present at corners, or turning vane regions. A calibration of the test sections was done. (3) The attractiveness of using rembedded grids for airfoil calculations modeled by the Euler equations was explored. These calculations were extended to C-type grids and then to Navier-Stokes calculations,

  7. The effects of once-weekly teriparatide on hip structure and biomechanical properties assessed by CT.

    PubMed

    Ito, M; Oishi, R; Fukunaga, M; Sone, T; Sugimoto, T; Shiraki, M; Nishizawa, Y; Nakamura, T

    2014-03-01

    Once-weekly administration of 56.5 μg teriparatide improved cortical bone parameters and biomechanical parameters at the proximal femur by CT geometry analysis. The aim of this study was to evaluate the effects of weekly administration of teriparatide [human PTH (1-34)] on bone geometry, volumetric bone mineral density (vBMD), and parameters of bone strength at the proximal femur which were longitudinally investigated using computed tomography (CT). The subjects were a subgroup of a recent, randomly assigned, double-blind study (578 subjects) comparing the anti-fracture efficacy of a once-weekly subcutaneous injection of 56.5 μg teriparatide with placebo (TOWER trial). Sixty-six ambulatory postmenopausal women with osteoporosis were enrolled at 15 study sites having multi-detector row CT, and included women injected with teriparatide (n = 29, 74.2 ± 5.1 years) or with placebo (n = 37, 74.8 ± 5.3 years). CT data were obtained at baseline and follow-up scans were performed at 48 and 72 weeks. The data were analyzed to obtain cross-sectional densitometric, geometric, and biomechanical parameters including the section modulus (SM) and buckling ratio (BR) of the femoral neck, inter-trochanter, and femoral shaft. We found that once-weekly teriparatide increased cortical thickness/cross-sectional area (CSA) and total area, and improved biomechanical properties (i.e., decreasing BR) at the femoral neck and shaft. Teriparatide did not change the cortical perimeter. Our longitudinal analysis of proximal femur geometry by CT revealed that once-weekly administration of 56.5 μg teriparatide improved cortical bone parameters at the femoral neck and shaft and also improved biomechanical parameters.

  8. NORTH ELEVATION OF GOLD HILL MILL, LOOKING SOUTH. AT LEFT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    NORTH ELEVATION OF GOLD HILL MILL, LOOKING SOUTH. AT LEFT EDGE IS THE SINGLE CYLINDER “HOT SHOT” ENGINE THAT PROVIDED POWER FOR THE MILL. JUST IN FRONT OF IT IS AN ARRASTRA. AT CENTER IS THE BALL MILL AND SECONDARY ORE BIN. JUST TO THE RIGHT OF THE BALL MILL IS A RAKE CLASSIFIER, AND TO THE RIGHT ARE THE CONCENTRATION TABLES. WARM SPRINGS CAMP IS IN THE DISTANCE. SEE CA-292-17 (CT) FOR IDENTICAL COLOR TRANSPARENCY. - Gold Hill Mill, Warm Spring Canyon Road, Death Valley Junction, Inyo County, CA

  9. [Mobile CT at neurointensive sections--it is possible].

    PubMed

    Frost, Majbritt; Stenkær, Susanne; Kellenberger, Simone; Ehlers, Lars

    2011-01-24

    Intrahospital transportation can be complicated and hazardous. Mobile computerized tomography (CT) of the head performed at the neurointensive care unit is a new technique that minimizes the need for transportation of unstable patients. Even small changes in physiological parameters can be detrimental for these patients and cause secondary injury and thus affect their prognoses. The portable CT scanner in the neurointensive care unit holds great potential, but the high price level may limit its use.

  10. 21 CFR 175.230 - Hot-melt strippable food coatings.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Hot-melt strippable food coatings. 175.230 Section 175.230 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: ADHESIVES AND COMPONENTS OF...

  11. 21 CFR 175.230 - Hot-melt strippable food coatings.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Hot-melt strippable food coatings. 175.230 Section 175.230 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: ADHESIVES AND COMPONENTS OF...

  12. 21 CFR 175.230 - Hot-melt strippable food coatings.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Hot-melt strippable food coatings. 175.230 Section 175.230 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: ADHESIVES AND COMPONENTS OF...

  13. 21 CFR 175.230 - Hot-melt strippable food coatings.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Hot-melt strippable food coatings. 175.230 Section 175.230 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) INDIRECT FOOD ADDITIVES: ADHESIVES AND COMPONENTS OF COATINGS Substances for Use as Components of...

  14. Performance comparison of PG 64-22 versus PG 64-28 asphalt in hot mix asphalt placed in Connecticut.

    DOT National Transportation Integrated Search

    2012-11-01

    This research was conducted to determine if switching from a low-temperature asphalt performance grade : (PG) of -28C to -22C would be detrimental to the performance of Hot Mix Asphalt (HMA) pavements in : Connecticut. Test sections were placed o...

  15. INTERIOR PHOTO OF HOT PILOT PLANT SECOND FLOOR WITH SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR PHOTO OF HOT PILOT PLANT SECOND FLOOR WITH SOUTH SECTION OF SHIELDED CAVE IN FOREGROUND (CPP-640) LOOKING NORTHWEST. INL PHOTO NUMBER HD-54-40-1. Mike Crane, Photographer, 7/2006 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  16. 29 CFR 1926.51 - Sanitation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... which meet the other requirements of this paragraph. (ii) Each lavatory shall be provided with hot and... each 10 employees of each sex, or numerical fraction thereof, who are required to shower during the... provided as specified in paragraph (f)(3)(iii) of this section. (iv) Showers shall be provided with hot and...

  17. 29 CFR 1926.51 - Sanitation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... which meet the other requirements of this paragraph. (ii) Each lavatory shall be provided with hot and... each 10 employees of each sex, or numerical fraction thereof, who are required to shower during the... provided as specified in paragraph (f)(3)(iii) of this section. (iv) Showers shall be provided with hot and...

  18. 29 CFR 1926.51 - Sanitation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... which meet the other requirements of this paragraph. (ii) Each lavatory shall be provided with hot and... each 10 employees of each sex, or numerical fraction thereof, who are required to shower during the... provided as specified in paragraph (f)(3)(iii) of this section. (iv) Showers shall be provided with hot and...

  19. An Efficient Pipeline for Abdomen Segmentation in CT Images.

    PubMed

    Koyuncu, Hasan; Ceylan, Rahime; Sivri, Mesut; Erdogan, Hasan

    2018-04-01

    Computed tomography (CT) scans usually include some disadvantages due to the nature of the imaging procedure, and these handicaps prevent accurate abdomen segmentation. Discontinuous abdomen edges, bed section of CT, patient information, closeness between the edges of the abdomen and CT, poor contrast, and a narrow histogram can be regarded as the most important handicaps that occur in abdominal CT scans. Currently, one or more handicaps can arise and prevent technicians obtaining abdomen images through simple segmentation techniques. In other words, CT scans can include the bed section of CT, a patient's diagnostic information, low-quality abdomen edges, low-level contrast, and narrow histogram, all in one scan. These phenomena constitute a challenge, and an efficient pipeline that is unaffected by handicaps is required. In addition, analysis such as segmentation, feature selection, and classification has meaning for a real-time diagnosis system in cases where the abdomen section is directly used with a specific size. A statistical pipeline is designed in this study that is unaffected by the handicaps mentioned above. Intensity-based approaches, morphological processes, and histogram-based procedures are utilized to design an efficient structure. Performance evaluation is realized in experiments on 58 CT images (16 training, 16 test, and 26 validation) that include the abdomen and one or more disadvantage(s). The first part of the data (16 training images) is used to detect the pipeline's optimum parameters, while the second and third parts are utilized to evaluate and to confirm the segmentation performance. The segmentation results are presented as the means of six performance metrics. Thus, the proposed method achieves remarkable average rates for training/test/validation of 98.95/99.36/99.57% (jaccard), 99.47/99.67/99.79% (dice), 100/99.91/99.91% (sensitivity), 98.47/99.23/99.85% (specificity), 99.38/99.63/99.87% (classification accuracy), and 98.98/99.45/99.66% (precision). In summary, a statistical pipeline performing the task of abdomen segmentation is achieved that is not affected by the disadvantages, and the most detailed abdomen segmentation study is performed for the use before organ and tumor segmentation, feature extraction, and classification.

  20. A new method to measure electron density and effective atomic number using dual-energy CT images

    NASA Astrophysics Data System (ADS)

    Ramos Garcia, Luis Isaac; Pérez Azorin, José Fernando; Almansa, Julio F.

    2016-01-01

    The purpose of this work is to present a new method to extract the electron density ({ρ\\text{e}} ) and the effective atomic number (Z eff) from dual-energy CT images, based on a Karhunen-Loeve expansion (KLE) of the atomic cross section per electron. This method was used to calibrate a Siemens Definition CT using the CIRS phantom. The predicted electron density and effective atomic number using 80 kVp and 140 kVp were compared with a calibration phantom and an independent set of samples. The mean absolute deviations between the theoretical and calculated values for all the samples were 1.7 %  ±  0.1 % for {ρ\\text{e}} and 4.1 %  ±  0.3 % for Z eff. Finally, these results were compared with other stoichiometric method. The application of the KLE to represent the atomic cross section per electron is a promising method for calculating {ρ\\text{e}} and Z eff using dual-energy CT images.

  1. Investigation of using steel slag in hot mix asphalt for the surface course of flexible pavements

    NASA Astrophysics Data System (ADS)

    Nguyen, Hien Q.; Lu, Dai X.; Le, Son D.

    2018-04-01

    The rapid development of heavy industry in Vietnam leads to the establishments of steel industry. Steel slag, a by-product of steelwork industry, under Vietnamese’s law, was considered as a deleterious solid waste which needed to be processed and landfilled. However, this has changed recently, and steel slag is now seen as a normal or non-deleterious solid waste, and has been studied for reuse in the construction industry. In this study, steel slag was used, as a replacement for mineral aggregate, in hot mix asphalt. Two hot mix asphalt mixtures with an equivalent nominal aggregate size of 12.5 (C12.5) and 19 mm (C19) were produced using steel slag. In addition, one conventional hot mix asphalt mixture of C19 was produced using mineral aggregate for comparison purpose. Investigation in laboratory condition and trial sections was carried out on Marshall tests, surface roughness, skid resistance, and modulus of the pavement before and after applying a new surface course of hot mix asphalt. The study showed that all steel slag asphalt mixtures passed the Marshall stability and flow test requirements. The skid resistance of steel slag hot mix asphalt mixtures for the surface course satisfied the Vietnamese specification for asphalt. Moreover, the pavement sections with the surface course of steel slag hot mix asphalt showed a considerable higher modulus than that of the conventional one. Only the roughness of the surface course paved with C19 did not pass the requirement of the specification.

  2. The Relation Between Alloy Chemistry and Hot-Cracking

    NASA Technical Reports Server (NTRS)

    Nunes, A. C., Jr.; Talia, J. E.

    2000-01-01

    Hot cracking is a problem in welding 2195 aluminum-lithium alloy. Weld wire additives seem to reduce the problem. This study proposes a model intended to clarify the way alloying elements affect hot-cracking. The brittle temperature range of an alloy extends wherever the tensile stress required to move the meniscus of the liquid film at the grain/dendrite boundaries is less than the bulks flow stress Sigma(sub B) of the grains: 2gamma/delta <= sigma(sub B) + P where gamma is boundary film surface tension delta= boundary film thickness P = gas pressure (Some alloys outgas.) If the above condition is not met, the grains deform under stress and the liquid film remains in place. Curves of 2gamma/delta and sigma(sub B) vs. temperature in the range just below the melting temperature determine the hot cracking susceptibility of an alloy. Both are zero at onset of solidification. sigma(sub B) rises as the thermal activation of the slip mechanism is reduced. 2gamma/delta rises as the film thickness delta which can be estimated from the Scheil equation, drops. But, given an embrittled alloy, whether the alloy actually cracks is determined by the strain imposed upon it in the embrittled condition. A critical strain is estimated, Epsilon(sub C) on the order of Epsilon(sub C) is approximately delta/l where L = grain size and where the the volume increment due to the strain, concentrated at the liquid film, is on the order of the liquid film volume. In the early 80's an empirical critical strain cracking envelope Epsilon(sub C)(T) was incorporated into a damage criterion to estimate the effect of welding parameters on the formation of microfissures in a superalloy with good results. These concepts, liquid film decoherence vs. grain bulk deformation and critical strain, form the key elements of a quantitative theory of hot-cracking applicable for assessing the effect of alloying elements on hot-cracking during welding.

  3. Hot flashes in breast cancer survivors: Frequency, severity and impact.

    PubMed

    Chang, Hao-Yuan; Jotwani, Aparna C; Lai, Yeur-Hur; Jensen, Mark P; Syrjala, Karen L; Fann, Jesse R; Gralow, Julie

    2016-06-01

    To (1) determine the frequency and severity of hot flashes, (2) examine the associations between hot flash frequency and severity and quality of life, and (3) identify the predictors of hot flash activity in breast cancer survivors. The study used a cross-sectional design and mailed survey of 253 breast cancer survivors recruited from a cancer wellness clinic. Participants provided information regarding cancer history, hot flashes, pain intensity, sleep problems, physical functioning, and psychological functioning. About half of the survivors reported at least one hot flash in the past 24 h (45%) or past week (52%). The average frequency of hot flashes was 1.9 in the past 24 h and 1.8 in the past week. Hot flash severity was usually mild or asymptomatic. However, participants with hot flashes reported significantly more sleep problems and higher pain severity than those reporting no hot flashes. Moreover, the severity of hot flashes was associated with more sleep problems, higher pain severity, and more psychological dysfunction. History of hormonal suppression therapy and younger age predicted hot flash activity in the study sample. In breast cancer survivors, hot flashes are common and are associated with unpleasant symptoms and poor quality of life. Research is needed to determine if treatments that reduce the frequency and severity of hot flashes in breast cancer survivors also result in improvements in symptoms such as sleep problems, pain, and psychological dysfunction. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Hot flashes in breast cancer survivors: Frequency, severity and impact

    PubMed Central

    Chang, Hao-Yuan; Jotwani, Aparna C.; Lai, Yeur-Hur; Jensen, Mark P.; Syrjala, Karen L.; Fann, Jesse R.; Gralow, Julie

    2018-01-01

    Purposes To (1) determine the frequency and severity of hot flashes, (2) examine the associations be- tween hot flash frequency and severity and quality of life, and (3) identify the predictors of hot flash activity in breast cancer survivors. Methods The study used a cross-sectional design and mailed survey of 253 breast cancer survivors recruited from a cancer wellness clinic. Participants provided information regarding cancer history, hot flashes, pain intensity, sleep problems, physical functioning, and psychological functioning. Results About half of the survivors reported at least one hot flash in the past 24 h (45%) or past week (52%). The average frequency of hot flashes was 1.9 in the past 24 h and 1.8 in the past week. Hot flash severity was usually mild or asymptomatic. However, participants with hot flashes reported significantly more sleep problems and higher pain severity than those reporting no hot flashes. Moreover, the severity of hot flashes was associated with more sleep problems, higher pain severity, and more psychological dysfunction. History of hormonal suppression therapy and younger age predicted hot flash activity in the study sample. Conclusions In breast cancer survivors, hot flashes are common and are associated with unpleasant symptoms and poor quality of life. Research is needed to determine if treatments that reduce the frequency and severity of hot flashes in breast cancer survivors also result in improvements in symptoms such as sleep problems, pain, and psychological dysfunction. PMID:27065357

  5. Hot tea and tiny tots don't mix: A cross-sectional survey on hot beverage scalds.

    PubMed

    Burgess, J D; Kimble, R M; Watt, K A; Cameron, C M

    2017-12-01

    Hot beverage scalds are a leading cause of burns in young children. The aim of this study was to look at the circumstances surrounding these injuries in terms of setting, mechanism, supervision and first aid to inform a prevention campaign. A cross-sectional study was delivered via iPad to parents and caregivers presenting with a child aged 0-36 months with a hot beverage scald at a major paediatric burns centre. Of the 101 children aged 0-36 months that presented with a hot beverage scald over a 12-month period, 54 participants were included. The scald aetiology was as expected with the peak prevalence in children aged 6-24 months, pulling a cup of hot liquid down over themselves. The majority of injuries occurred in the child's home and were witnessed by the caregiver or parent. The supervising adult was often in close proximity when the scald occurred. Less than a third (28%) of participants received recommended first aid treatment at the scene, with an additional 18% receiving this treatment with three hours of the injury-usually at an emergency department. While the aetiology of these scalds were as expected, the low use of recommended burn first aid was of concern. Although supervision was present in almost all cases, with the parent/caregiver close-by, this proximity still permitted injury. Attentiveness and continuity of supervision, which can be difficult with competing parental demands, appear to play a more important role role; as do considerations of other safety mechanisms such as hazard reduction through keeping hot drinks out of reach and engineering factors such as improved cup design. By incorporating the findings from this study and other research into a hot beverage scald prevention campaign, we hope to see a change in knowledge and behaviour in parents and caregivers of young children, and ultimately a reduction in the incidence of hot beverage scalds. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  6. [The diagnostic value of dual-energy CT and 3 Tesla MRI in the diagnosis of German Mardi Gras donuts--where is the mustard, where is the custard and where is the jam?].

    PubMed

    Morhard, D; Dietrich, O; Reiser, M; Ertl-Wagner, B

    2008-04-01

    As a Mardi Gras joke, the original jam or custard fillings of German Mardi Gras donuts are frequently replaced with mustard which cannot be identified on the outside of the donut. The aim of our study was to evaluate the impact of modern CT and MRI techniques on the diagnostic evaluation of donuts filled with mustard, jam or custard. 4 commercially available donuts were included in the study. One was filled with custard (PK) and one with jam (MK). Two donuts were specifically prepared and filled with Bavarian mustard (SK1) or extra-hot (SK2) mustard. 3 Tesla MRI was performed with T 2- and T 1-weighted STIR, diffusion and susceptibility-weighted (SWI) sequences. In addition, the donuts underwent dual-energy CT. PK was able to be easily differentiated from the other donuts due to its hyperintensity in the STIR sequences and hypointensity in the T 1-weighted sequences. MK was able to be differentiated from S 1K and S 2K on the basis of its diffusion properties. S 1K demonstrated a pronounced heterogeneity of its matrix, especially in SWI. In CT, PK showed a pronounced hypoattenuation with negative Hounsfield units in contrast to the strongly hyperdense MK, S 1K and S 2K. S 1K and S 2K demonstrated X-ray attenuation considerably dependent on the X-ray energy. Donuts filled with jam, custard or mustard can be readily differentiated by modern MRI and CT techniques. Therefore, eating a mustard-filled donut can be reliably avoided.

  7. Performance evaluation of the Ingenuity TF PET/CT scanner with a focus on high count-rate conditions

    NASA Astrophysics Data System (ADS)

    Kolthammer, Jeffrey A.; Su, Kuan-Hao; Grover, Anu; Narayanan, Manoj; Jordan, David W.; Muzic, Raymond F.

    2014-07-01

    This study evaluated the positron emission tomography (PET) imaging performance of the Ingenuity TF 128 PET/computed tomography (CT) scanner which has a PET component that was designed to support a wider radioactivity range than is possible with those of Gemini TF PET/CT and Ingenuity TF PET/MR. Spatial resolution, sensitivity, count rate characteristics and image quality were evaluated according to the NEMA NU 2-2007 standard and ACR phantom accreditation procedures; these were supplemented by additional measurements intended to characterize the system under conditions that would be encountered during quantitative cardiac imaging with 82Rb. Image quality was evaluated using a hot spheres phantom, and various contrast recovery and noise measurements were made from replicated images. Timing and energy resolution, dead time, and the linearity of the image activity concentration, were all measured over a wide range of count rates. Spatial resolution (4.8-5.1 mm FWHM), sensitivity (7.3 cps kBq-1), peak noise-equivalent count rate (124 kcps), and peak trues rate (365 kcps) were similar to those of the Gemini TF PET/CT. Contrast recovery was higher with a 2 mm, body-detail reconstruction than with a 4 mm, body reconstruction, although the precision was reduced. The noise equivalent count rate peak was broad (within 10% of peak from 241-609 MBq). The activity measured in phantom images was within 10% of the true activity for count rates up to those observed in 82Rb cardiac PET studies.

  8. The MHOST finite element program: 3-D inelastic analysis methods for hot section components. Volume 3: Systems' manual

    NASA Technical Reports Server (NTRS)

    Nakazawa, Shohei

    1989-01-01

    The internal structure is discussed of the MHOST finite element program designed for 3-D inelastic analysis of gas turbine hot section components. The computer code is the first implementation of the mixed iterative solution strategy for improved efficiency and accuracy over the conventional finite element method. The control structure of the program is covered along with the data storage scheme and the memory allocation procedure and the file handling facilities including the read and/or write sequences.

  9. Investigation of the Direct Charge Transfer in Low Energy D2+ + H Collisions using Merged-Beams Technique

    NASA Astrophysics Data System (ADS)

    Romano, S. L.; Guillen, C. I.; Andrianarijaona, V. M.; Havener, C. C.

    2011-10-01

    The hydrogen - hydrogen (deuterium) molecular ion is the most fundamental ion-molecule two-electron system. Charge transfer (CT) for H2+ on H, which is one of the possible reaction paths for the (H-H2)+ system, is of special interest because of its contribution to H2 formation in the early universe, its exoergicity, and rich collision dynamics. Due to technical difficulty in making an atomic H target, the direct experimental investigations of CT for H2+ on H are sparse and generally limited to higher collision energies. The measurements of the absolute cross section of different CT paths for H2+ on H over a large range of collision energy are needed to benchmark theoretical calculations, especially the ones at low energies. The rate coefficient of CT at low energy is not known but may be comparable to other reaction rate coefficients in cold plasmas with H, H+, H2+, and H3+ as constituents. For instance, CT for H2+ on H and the following H3+ formation reaction H2+ + H2 → H + H3+ are clearly rate interdependent although it was always assumed that every ionization of H2 will lead to the formation of H3+. CT proceeds through dynamically coupled electronic, vibrational and rotational degrees of freedom. One can depict three paths, electronic CT, CT with nuclear substitution, and CT with dissociation. Electronic CT and CT with nuclear substitution in the H2+ on H collisions are not distinguishable by any quantum theory. Here we use the isotopic system (D2+ - H) to measure without ambiguity the electronic CT cross section by observing the H+ products. Using the ion-atom merged-beam apparatus at Oak Ridge National Laboratory, the absolute direct CT cross sections for D2+ + H from keV/u to meV/u collision energies have been measured. The molecular ions are extracted from an Electron-Cyclotron Resonance (ECR) ion source with a vibrational state distribution which is most likely determined by Frank-Condon transitions between ground state D2 and D2+. A ground-state H beam is obtained by photo-detachment of H-. Our first measurements are presented in Fig. 1 along with the theories and previous experiments. The collision is rovibrationally frozen at high energy where our measurements are seen to be in good agreement with the high energy theory. Both measurements and low energy theory increase toward low energies where the collision times are long enough to sample vibrational and rotational modes. This research is supported by the National Science Foundation through grant PHY-1068877 and by the Office of Fusion Energy Sciences and the Office of Basic Energy Sciences, U.S. DOE, Contract No. DE-AC05-00OR22725 with UT-Battelle, LLC.

  10. Effective doses to patients undergoing thoracic computed tomography examinations.

    PubMed

    Huda, W; Scalzetti, E M; Roskopf, M

    2000-05-01

    The purpose of this study was to investigate how x-ray technique factors and effective doses vary with patient size in chest CT examinations. Technique factors (kVp, mAs, section thickness, and number of sections) were recorded for 44 patients who underwent a routine chest CT examination. Patient weights were recorded together with dimensions and mean Hounsfield unit values obtained from representative axial CT images. The total mass of directly irradiated patient was modeled as a cylinder of water to permit the computation of the mean patient dose and total energy imparted for each chest CT examination. Computed values of energy imparted during the chest CT examination were converted into effective doses taking into account the patient weight. Patient weights ranged from 4.5 to 127 kg, and half the patients in this study were children under 18 years of age. All scans were performed at 120 kVp with a 1 s scan time. The selected tube current showed no correlation with patient weight (r2=0.06), indicating that chest CT examination protocols do not take into account for the size of the patient. Energy imparted increased with increasing patient weight, with values of energy imparted for 10 and 70 kg patients being 85 and 310 mJ, respectively. The effective dose showed an inverse correlation with increasing patient weight, however, with values of effective dose for 10 and 70 kg patients being 9.6 and 5.4 mSv, respectively. Current CT technique factors (kVp/mAs) used to perform chest CT examinations result in relatively high patient doses, which could be reduced by adjusting technique factors based on patient size.

  11. Comparisons of the diagnostic accuracies of optical coherence tomography, micro-computed tomography, and histology in periodontal disease: an ex vivo study

    PubMed Central

    2017-01-01

    Purpose Optical coherence tomography (OCT) is a noninvasive diagnostic technique that may be useful for both qualitative and quantitative analyses of the periodontium. Micro-computed tomography (micro-CT) is another noninvasive imaging technique capable of providing submicron spatial resolution. The purpose of this study was to present periodontal images obtained using ex vivo dental OCT and to compare OCT images with micro-CT images and histologic sections. Methods Images of ex vivo canine periodontal structures were obtained using OCT. Biologic depth measurements made using OCT were compared to measurements made on histologic sections prepared from the same sites. Visual comparisons were made among OCT, micro-CT, and histologic sections to evaluate whether anatomical details were accurately revealed by OCT. Results The periodontal tissue contour, gingival sulcus, and the presence of supragingival and subgingival calculus could be visualized using OCT. OCT was able to depict the surface topography of the dentogingival complex with higher resolution than micro-CT, but the imaging depth was typically limited to 1.2–1.5 mm. Biologic depth measurements made using OCT were a mean of 0.51 mm shallower than the histologic measurements. Conclusions Dental OCT as used in this study was able to generate high-resolution, cross-sectional images of the superficial portions of periodontal structures. Improvements in imaging depth and the development of an intraoral sensor are likely to make OCT a useful technique for periodontal applications. PMID:28261522

  12. X-ray CT core imaging of Oman Drilling Project on D/V CHIKYU

    NASA Astrophysics Data System (ADS)

    Michibayashi, K.; Okazaki, K.; Leong, J. A. M.; Kelemen, P. B.; Johnson, K. T. M.; Greenberger, R. N.; Manning, C. E.; Harris, M.; de Obeso, J. C.; Abe, N.; Hatakeyama, K.; Ildefonse, B.; Takazawa, E.; Teagle, D. A. H.; Coggon, J. A.

    2017-12-01

    We obtained X-ray computed tomography (X-ray CT) images for all cores (GT1A, GT2A, GT3A and BT1A) in Oman Drilling Project Phase 1 (OmanDP cores), since X-ray CT scanning is a routine measurement of the IODP measurement plan onboard Chikyu, which enables the non-destructive observation of the internal structure of core samples. X-ray CT images provide information about chemical compositions and densities of the cores and is useful for assessing sample locations and the quality of the whole-round samples. The X-ray CT scanner (Discovery CT 750HD, GE Medical Systems) on Chikyu scans and reconstructs the image of a 1.4 m section in 10 minutes and produces a series of scan images, each 0.625 mm thick. The X-ray tube (as an X-ray source) and the X-ray detector are installed inside of the gantry at an opposing position to each other. The core sample is scanned in the gantry with the scanning rate of 20 mm/sec. The distribution of attenuation values mapped to an individual slice comprises the raw data that are used for subsequent image processing. Successive two-dimensional (2-D) slices of 512 x 512 pixels yield a representation of attenuation values in three-dimensional (3-D) voxels of 512 x 512 by 1600 in length. Data generated for each core consist of core-axis-normal planes (XY planes) of X-ray attenuation values with dimensions of 512 × 512 pixels in 9 cm × 9 cm cross-section, meaning at the dimensions of a core section, the resolution is 0.176 mm/pixel. X-ray intensity varies as a function of X-ray path length and the linear attenuation coefficient (LAC) of the target material is a function of the chemical composition and density of the target material. The basic measure of attenuation, or radiodensity, is the CT number given in Hounsfield units (HU). CT numbers of air and water are -1000 and 0, respectively. Our preliminary results show that CT numbers of OmanDP cores are well correlated to gamma ray attenuation density (GRA density) as a function of chemical composition and mineral density, so that their profiles with respect to the core depth provide quick lithological information such as mineral identification and phase boundary etc. Moreover, X-ray CT images can be used for 3-D fabric analyses of the whole core even after core cutting into halves for individual analyses.

  13. CTEQ-TEA parton distribution functions and HERA Run I and II combined data

    NASA Astrophysics Data System (ADS)

    Hou, Tie-Jiun; Dulat, Sayipjamal; Gao, Jun; Guzzi, Marco; Huston, Joey; Nadolsky, Pavel; Pumplin, Jon; Schmidt, Carl; Stump, Daniel; Yuan, C.-P.

    2017-02-01

    We analyze the impact of the recent HERA Run I +II combination of inclusive deep inelastic scattering cross-section data on the CT14 global analysis of parton distribution functions (PDFs). New PDFs at next-to-leading order and next-to-next-to-leading order, called CT14 HERA 2 , are obtained by a refit of the CT14 data ensembles, in which the HERA Run I combined measurements are replaced by the new HERA Run I +II combination. The CT14 functional parametrization of PDFs is flexible enough to allow good descriptions of different flavor combinations, so we use the same parametrization for CT14 HERA 2 but with an additional shape parameter for describing the strange quark PDF. We find that the HERA I +II data can be fit reasonably well, and both CT14 and CT14 HERA 2 PDFs can describe equally well the non-HERA data included in our global analysis. Because the CT14 and CT14 HERA 2 PDFs agree well within the PDF errors, we continue to recommend CT14 PDFs for the analysis of LHC Run 2 experiments.

  14. 40 CFR 52.2087 - Original identification of plan section.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Content in Fuels” and 13, “Particulate Emissions from Fossil Fired Steam or Hot Water Generating Units..., “Sulfur Content of Fuels” and 13, “Particulate Emissions from Fossil Fuel Fired Steam or Hot Water... incorporated by reference in its present form on July 6, 1984 at paragraph (c)(22), above. The entire...

  15. 40 CFR 52.2087 - Original identification of plan section.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Content in Fuels” and 13, “Particulate Emissions from Fossil Fired Steam or Hot Water Generating Units..., “Sulfur Content of Fuels” and 13, “Particulate Emissions from Fossil Fuel Fired Steam or Hot Water... incorporated by reference in its present form on July 6, 1984 at paragraph (c)(22), above. The entire...

  16. 40 CFR 52.2087 - Original identification of plan section.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Content in Fuels” and 13, “Particulate Emissions from Fossil Fired Steam or Hot Water Generating Units..., “Sulfur Content of Fuels” and 13, “Particulate Emissions from Fossil Fuel Fired Steam or Hot Water... incorporated by reference in its present form on July 6, 1984 at paragraph (c)(22), above. The entire...

  17. 40 CFR 52.2087 - Original identification of plan section.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Content in Fuels” and 13, “Particulate Emissions from Fossil Fired Steam or Hot Water Generating Units..., “Sulfur Content of Fuels” and 13, “Particulate Emissions from Fossil Fuel Fired Steam or Hot Water... incorporated by reference in its present form on July 6, 1984 at paragraph (c)(22), above. The entire...

  18. 40 CFR 52.2087 - Original identification of plan section.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Content in Fuels” and 13, “Particulate Emissions from Fossil Fired Steam or Hot Water Generating Units..., “Sulfur Content of Fuels” and 13, “Particulate Emissions from Fossil Fuel Fired Steam or Hot Water... incorporated by reference in its present form on July 6, 1984 at paragraph (c)(22), above. The entire...

  19. CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP640) LOOKING NORTHEAST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP-640) LOOKING NORTHEAST SHOWING DECK FORMING FOR SOUTH SECTION OF OPERATING CORRIDOR; CONSTRUCTION 44 PERCENT COMPLETE. INL PHOTO NUMBER NRTS-60-3624. Holmes, Photographer, 7/25/1960 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  20. 16 CFR 1505.51 - Hot surfaces.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...

  1. 16 CFR 1505.51 - Hot surfaces.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...

  2. 16 CFR 1505.51 - Hot surfaces.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...

  3. 21 CFR 890.5720 - Water circulating hot or cold pack.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Water circulating hot or cold pack. 890.5720 Section 890.5720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5720 Water...

  4. 21 CFR 890.5720 - Water circulating hot or cold pack.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Water circulating hot or cold pack. 890.5720 Section 890.5720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5720 Water...

  5. 21 CFR 890.5720 - Water circulating hot or cold pack.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Water circulating hot or cold pack. 890.5720 Section 890.5720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5720 Water...

  6. 21 CFR 890.5720 - Water circulating hot or cold pack.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Water circulating hot or cold pack. 890.5720 Section 890.5720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5720 Water...

  7. 21 CFR 890.5720 - Water circulating hot or cold pack.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Water circulating hot or cold pack. 890.5720 Section 890.5720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5720 Water...

  8. 30 CFR 77.303 - Hot gas inlet chamber dropout doors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 77.303 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND... employ a hot gas inlet chamber shall be equipped with drop-out doors at the bottom of the inlet chamber...

  9. Evaluation of a New Motion-correction Algorithm Using On-rigid Registration in Respiratory-gated PET/CT Images of Liver Tumors.

    PubMed

    Wagatsuma, Kei; Osawa, Tatsufumi; Yokokawa, Naoki; Miwa, Kenta; Oda, Keiichi; Kudo, Yoshiro; Unno, Yasushi; Ito, Kimiteru; Ishii, Kenji

    2016-01-01

    The present study aimed to determine the qualitative and quantitative accuracy of the Q.Freeze algorithm in PET/CT images of liver tumors. A body phantom and hot spheres representing liver tumors contained 5.3 and 21.2 kBq/mL of a solution containing 18 F radioactivity, respectively. The phantoms were moved in the superior-inferior direction at a motion displacement of 20 mm. Conventional respiratory-gated (RG) and Q.Freeze images were sorted into 6, 10, and 13 phase-groups. The SUV ave was calculated from the background of the body phantom, and the SUV max was determined from the hot spheres of the liver tumors. Three patients with four liver tumors were also clinically assessed by whole-body and RG PET. The RG and Q.Freeze images derived from the clinical study were also sorted into 6, 10 and 13 phase-groups. Liver signal-to-noise ratio (SNR) and SUV max were determined from the RG and Q.Freeze clinical images. The SUV ave of Q.Freeze images was the same as those derived from the body phantom using RG. The liver SNR improved with Q.Freeze, and the SUVs max was not overestimated when Q.Freeze was applied in both the phantom and clinical studies. Q.Freeze did not degrade the liver SNR and SUV max even though the phase number was larger. Q.Freeze delivered qualitative and quantitative motion correction than conventional RG imaging even in 10-phase groups.

  10. Breakdown electric fields in dissociated hot gas mixtures of sulfur hexafluoride including teflon: Calculations with experimental validations and utilization in fluid dynamics arc simulations

    NASA Astrophysics Data System (ADS)

    Yousfi, M.; Merbahi, N.; Reichert, F.; Petchanka, A.

    2017-03-01

    Measurements of breakdown voltage Vb, gas temperature Tg, and density N and the associated critical electric field Ecr/N are performed in hot dissociated SF6 highly diluted in argon and in hot dissociated SF6 mixed with PTFE (Polytetrafluoroethylene or C2F4) also highly diluted in argon. Gases are heated using a microwave source and optical emission spectroscopy is used for measurements of Tg and N while Vb is measured from a specific inter-electrode arrangement placed inside of the cell of the hot gas conditioning. The experimental Ecr/N data in the numerous considered cases of gas temperatures and compositions have been used to evaluate and validate the sets of the collision cross sections of the 11 species involved in hot dissociated SF6 (i.e., SF6, SF5, SF4, S2F2, SF3, SF2, SF, S2, F2, F, and S), the 13 additional species involved either in hot C2F4 or CF4 (C2F6, C2F4, C2F2, CF4, CF3, CF2, CF, F2, F and carbon species as C, C2, C3, C4) and also the 2 further species (CS and CS2) present only in the considered mixtures SF6 + C2F4. The fitted sets of collision cross sections of all these 26 species are then used without argon dilution in hot SF6 and hot SF6 + C2F4 mixtures to calculate and to analyze the Ecr/N data obtained for a wide range of gas temperature (up to 4000 K) and gas pressure (8 bar and more) using a rigorous multi-term solution of the Boltzmann equation for electron energy distribution function and standard calculations of hot gas composition for the species proportions. Such Ecr/N data have been then successfully used to evaluate from a Computational Fluid Dynamics model the switching capacity at terminal fault from a coupled simulation of the electrostatic field and the hot gas flow after current zero.

  11. 7. SECTION VIEW EAST, WEST END OF DAM, DECEMBER 1995, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. SECTION VIEW EAST, WEST END OF DAM, DECEMBER 1995, SHOWING 1915 CRIBBING; 1882 MASONRY ON LEFT - Norwich Water Power Company, Dam, West bank of Shetucket River opposite Fourteenth Street, Greenville section, Norwich, New London County, CT

  12. Sarcopenia as a predictor of mortality in elderly blunt trauma patients: Comparing the masseter to the psoas using computed tomography.

    PubMed

    Wallace, James D; Calvo, Richard Y; Lewis, Paul R; Brill, Jason B; Shackford, Steven R; Sise, Michael J; Sise, C Beth; Bansal, Vishal

    2017-01-01

    Sarcopenia, or age-related loss of muscle mass, is measurable by computed tomography (CT). In elderly trauma patients, increased mortality is associated with decreased psoas muscle cross-sectional area (P-Area) on abdominal CT. Fall is the leading cause of injury in the elderly, and head CT is more often obtained. Masseter muscle cross-sectional area (M-Area) is readily measured on head CT. Hypothesizing that M-Area is a satisfactory surrogate for P-Area, we compared the two as markers of sarcopenia and increased mortality in elderly trauma patients. All blunt-injured patients aged 65 years or older admitted to our trauma center during 2010 were included. Two-year postdischarge mortality was identified by matching records to county, state, and national death indices. Bilateral M-Area was measured on admission head CT at 2 cm below the zygomatic arch. Bilateral P-Area was measured on abdominal CT at the fourth vertebral body. Average M-Area and P-Area values were calculated for each patient. Cox proportional hazards models evaluated the relationship of M-Area and P-Area with mortality. Model predictive performance was calculated using concordance statistics. Among 487 patients, 357 with M-Area and 226 with P-Area were identified. Females had smaller M-Area (3.43 cm vs 4.18 cm; p < 0.050) and P-Area (6.50 cm vs 10.9 cm; p < 0.050) than males. Masseter muscle cross-sectional area correlated with P-Area (rho, 0.38; p < 0.001). Adjusted Cox regression models revealed decreased survival associated with declining M-Area (hazard ratio, 0.76; 95% confidence interval, 0.60-0.96) and P-Area (hazard ratio, 0.68; 95% confidence interval, 0.46-1.00). Masseter muscle cross-sectional area and P-Area discriminated equally well in best-fit models. In elderly trauma patients, M-Area is an equally valid and more readily available marker of sarcopenia and 2-year mortality than P-Area. Future study should validate M-Area as a metric to identify at-risk patients who may benefit from early intervention. Prognostic study, level III.

  13. Using MicroCT to Assess Periodontal Regeneration Outcomes-Comparison of Image-Based and Histologic Results: A Case Report.

    PubMed

    Rebaudi, Alberto; Trisi, Paolo; Pagni, Giorgio; Wang, Hom-Lay

    The purpose of this study was to compare microcomputed tomography (microCT) and histologic analysis outcomes of a periodontal regeneration of a human defect treated with a polylactic- and polyglycolic-acid copolymer. At 11 months following the grafting procedure, the root with the surrounding periodontal tissues was removed and analyzed using microCT and histologic techniques. The results suggest that microCT three-dimensional analysis may be used in synergy with two-dimensional histologic sections to provide additional information for studying the regeneration outcomes normally reported by histologic biopsies in humans. Additional data is needed to validate these findings.

  14. Heat Pipe-Assisted Thermoelectric Power Generation Technology for Waste Heat Recovery

    NASA Astrophysics Data System (ADS)

    Jang, Ju-Chan; Chi, Ri-Guang; Rhi, Seok-Ho; Lee, Kye-Bock; Hwang, Hyun-Chang; Lee, Ji-Su; Lee, Wook-Hyun

    2015-06-01

    Currently, large amounts of thermal energy dissipated from automobiles are emitted through hot exhaust pipes. This has resulted in the need for a new efficient recycling method to recover energy from waste hot exhaust gas. The present experimental study investigated how to improve the power output of a thermoelectric generator (TEG) system assisted by a wickless loop heat pipe (loop thermosyphon) under the limited space of the exhaust gas pipeline. The present study shows a novel loop-type heat pipe-assisted TEG concept to be applied to hybrid vehicles. The operating temperature of a TEG's hot side surface should be as high as possible to maximize the Seebeck effect. The present study shows a novel TEG concept of transferring heat from the source to the sink. This technology can transfer waste heat to any local place with a loop-type heat pipe. The present TEG system with a heat pipe can transfer heat and generate an electromotive force power of around 1.3 V in the case of 170°C hot exhaust gas. Two thermoelectric modules (TEMs) for a conductive block model and four Bi2Te3 TEMs with a heat pipe-assisted model were installed in the condenser section. Heat flows to the condenser section from the evaporator section connected to the exhaust pipe. This novel TEG system with a heat pipe can be placed in any location on an automobile.

  15. Comparing two quantitative methods for studying remineralization of artificial caries.

    PubMed

    Lo, E C M; Zhi, Q H; Itthagarun, A

    2010-04-01

    To compare the detection of changes before and after remineralization of artificial enamel and dentin caries by microCT scanning, polarized light microscopy (PLM) and transverse microradiography (TMR). Fourteen extracted premolars were cut into tooth blocks and painted with an acid-resistant varnish leaving one enamel and one dentin surface exposed. The tooth blocks were immersed into demineralizing solution for 4 days to produce artificial caries-like lesions and scanned by microCT. Then the 14 tooth blocks were randomly allocated into two groups. Seven tooth blocks in Group I were cut longitudinally through the exposed surface into 100-150 microm thick sections and microradiographs were taken. The other seven tooth blocks in Group II were left intact. All the tooth blocks and sections were then immersed into remineralizing solution for 5 days. PLM and TMR of the tooth sections in Group I were taken again. Depth of the lesion on the TMR was measured. Tooth blocks in Group II were scanned by microCT. Mean lesion depth in Group I reduced by 13.0% and 8.2% after remineralization for enamel and dentin, respectively (paired t-test, P<0.001). In Group II, linear attenuation coefficient (LAC) of the region of interest (ROI) increased by 11.1% and 23.8% after remineralization for enamel and dentin lesions, respectively (paired t-test, P<0.001). Both microCT and microradiography are able to detect a change of similar magnitude in the artificial caries lesions after remineralization. MicroCT may be used to substitute TMR and PLM in in vitro studies about caries. Copyright 2010 Elsevier Ltd. All rights reserved.

  16. Sleep disturbance in men receiving androgen deprivation therapy for prostate cancer: The role of hot flashes and nocturia.

    PubMed

    Gonzalez, Brian D; Small, Brent J; Cases, Mallory G; Williams, Noelle L; Fishman, Mayer N; Jacobsen, Paul B; Jim, Heather S L

    2018-02-01

    Patients with prostate cancer receiving androgen deprivation therapy (ADT) are at risk of sleep disturbance; however, to the authors' knowledge, the mechanisms by which ADT may affect sleep are not well understood. The current study compared objective and subjective sleep disturbance in ADT recipients and controls and examined whether sleep disturbance in ADT recipients is attributable to the influence of ADT on hot flashes and nocturia. Patients with prostate cancer were assessed before or within 1 month after the initiation of ADT as well as 6 months and 12 months later (78 patients). Patients with prostate cancer were treated with prostatectomy only (99 patients) and men with no history of cancer (108 men) were assessed at similar intervals. Participants self-reported their sleep disturbance (Insomnia Severity Index) and interference from hot flashes (Hot Flash Related Daily Interference Scale). One hundred participants also wore actigraphs for 3 days at the 6-month assessment to measure objective sleep disturbance and reported their nocturia frequency. ADT recipients reported worse sleep disturbance, higher rates of clinically significant sleep disturbance, and greater hot flash interference than controls (Ps≤.03). In cross-sectional analyses among those with actigraphy data, ADT recipients had greater objective sleep disturbance and more episodes of nocturia (Ps<.01). Cross-sectional mediation analyses demonstrated that the association between ADT and objectively and subjectively measured sleep disturbance was partly attributable to nocturia and hot flashes (Ps<.05). The results of the current study suggest that the association between ADT and sleep may be partly explained by nocturia and hot flash interference. Future studies should examine behavioral and pharmacologic interventions to address these symptoms among ADT recipients. Cancer 2018;124:499-506. © 2017 American Cancer Society. © 2017 American Cancer Society.

  17. Assessment of anterior shoulder instability by CT arthrography.

    PubMed

    Yang, S O; Cho, K J; Kim, M J; Ro, I W

    1987-09-01

    Computed tomography (CT) immediately after double-contrast shoulder arthrography was taken in twenty-two young male patients with anterior shoulder instability including recurrent dislocation and subluxation. This recently developed technique called CT arthrography can provide significant information about patients with glenohumeral instability which is difficult to obtain by conventional arthrography. Information about glenoid labrum pathology is useful for proper management of the shoulder with instability. Lesions identified in this study include anterior labral defects (attenuation, tear, displacement), anterior capsular distension and/or detachment, Hill-Sachs lesion, anterior glenoid rim compression fracture, and fracture of scapula. This article describes the method used in CT arthrography of the glenohumeral joint, reviews the normal cross-sectional anatomy, and emphasizes the importance of the application of CT arthrography in the shoulder disorder with instability. CT arthrography of the glenohumeral joint is easy to perform, is accurate, and has lower radiation dose than arthrotomography.

  18. Considerations in development and implementation of elasto-viscoplastic constitutive model for high temperature applications

    NASA Technical Reports Server (NTRS)

    Riff, Richard

    1988-01-01

    The prediction of inelastic behavior of metallic materials at elevated temperatures has increased in importance in recent years. The operating conditions within the hot section of a rocket motor or a modern gas turbine engine present an extremely harsh thermomechanical environment. Large thermal transients are induced each time the engine is started or shut down. Additional thermal transients from an elevated ambient occur whenever the engine power level is adjusted to meet flight requirements. The structural elements employed in such hot sections, as well as any engine components located therein, must be capable of withstanding such extreme conditions. Failure of a component would, due to the critical nature of the hot section, lead to an immediate and catastrophic loss in power. Consequently, assuring satisfactory long term performance for such components is a major concern. Nonisothermal loading of structures often causes excursion of stress well into the inelastic range. Moreover, the influence of geometry changes on the response is also significant in most cases. Therefore, both material and geometric nonlinear effects are considered.

  19. Life prediction and constitutive behavior

    NASA Technical Reports Server (NTRS)

    Halford, G. R.

    1983-01-01

    One of the primary drivers that prompted the initiation of the hot section technology (HOST) program was the recognized need for improved cyclic durability of costly hot section components. All too frequently, fatigue in one form or another was directly responsible for the less than desired durability, and prospects for the future weren't going to improve unless a significant effort was mounted to increase our knowledge and understanding of the elements governing cyclic crack initiation and propagation lifetime. Certainly one of the important factors is the ability to perform accurate structural stress-strain analyses on a routine basis to determine the magnitudes of the localized stresses and strains since it is these localized conditions that govern the initiation and crack growth processes. Developing the ability to more accurately predict crack initiation lifetimes and cyclic crack growth rates for the complex loading conditions found in turbine engine hot sections is of course the ultimate goal of the life prediction research efforts. It has been found convenient to divide the research efforts into those dealing with nominally isotropic and anisotropic alloys; the latter for application to directionally solidified and single crystal turbine blades.

  20. A Method for the Automatic Exposure Control in Pediatric Abdominal CT: Application to the Standard Deviation Value and Tube Current Methods by Using Patient's Age and Body Size.

    PubMed

    Furuya, Ken; Akiyama, Shinji; Nambu, Atushi; Suzuki, Yutaka; Hasebe, Yuusuke

    2017-01-01

    We aimed to apply the pediatric abdominal CT protocol of Donnelly et al. in the United States to the pediatric abdominal CT-AEC. Examining CT images of 100 children, we found that the sectional area of the hepatic portal region (y) was strongly correlated with the body weight (x) as follows: y=7.14x + 84.39 (correlation coefficient=0.9574). We scanned an elliptical cone phantom that simulates the human body using a pediatric abdominal CT scanning method of Donnelly et al. in, and measured SD values. We further scanned the same phantom under the settings for adult CT-AEC scan and obtained the relationship between the sectional areas (y) and the SD values. Using these results, we obtained the following preset noise factors for CT-AEC at each body weight range: 6.90 at 4.5-8.9 kg, 8.40 at 9.0-17.9 kg, 8.68 at 18.0-26.9 kg, 9.89 at 27.0-35.9 kg, 12.22 at 36.0-45.0 kg, 13.52 at 45.1-70.0 kg, 15.29 at more than 70 kg. From the relation between age, weight and the distance of liver and tuber ischiadicum of 500 children, we obtained the CTDI vol values and DLP values under the scanning protocol of Donnelly et al. Almost all of DRL from these values turned out to be smaller than the DRL data of IAEA and various countries. Thus, by setting the maximum current values of CT-AEC to be the Donnelly et al.'s age-wise current values, and using our weight-wise noise factors, we think we can perform pediatric abdominal CT-AEC scans that are consistent with the same radiation safety and the image quality as those proposed by Donnelly et al.

  1. Atelectasis observed by computerized tomography after Caesarean section.

    PubMed

    Meira, M N C; Carvalho, C R R; Galizia, M S; Borges, J B; Kondo, M M; Zugaib, M; Vieira, J E

    2010-06-01

    Atelectasis after either vaginal or Caesarean delivery has not been adequately quantified. This study addresses the hypothesis that atelectasis may be worse in women who undergo Caesarean section when compared with vaginal delivery under regional anaesthesia. Twenty healthy non-smoking women submitted to a chest computed tomography (CT) 2 h after delivery in a University Hospital, who had experienced vaginal delivery (n=10) under combined spinal-epidural analgesia or a Caesarean section (n=10) under spinal anaesthesia, were evaluated. The percentage cross-sectional area of atelectasis in dependent lung regions were measured from the CT images obtained at cross-section of the xiphoid process and the top of the diaphragm. The percentage cross-sectional area of atelectasis was 3.95% in the vaginal delivery group and 14.1% in the Caesarean group (P<0.001, Mann-Whitney rank sum test). These results suggested that pulmonary atelectasis is greater after Caesarean section delivery under spinal anaesthesia than after vaginal delivery with combined spinal-epidural analgesia.

  2. Electrocardiographically gated 16-section CT of the thorax: cardiac motion suppression.

    PubMed

    Hofmann, Lars K; Zou, Kelly H; Costello, Philip; Schoepf, U Joseph

    2004-12-01

    Thirty patients underwent 16-section multi-detector row computed tomographic (CT) angiography of the thorax with retrospective electrocardiographic gating. Institutional review board approval was obtained for retrospective analysis of CT scan data and records; patient informed consent was not required. Images reconstructed at six different time points (0%, 20%, 40%, 50%, 60%, 80%) within the R-R interval on the electrocardiogram were analyzed by two radiologists for diagnostic quality, to identify suitable reconstruction intervals for optimal suppression of cardiac motion. Five regions of interest (left coronary artery, aortic root, ascending and descending aorta, pulmonary arteries) were evaluated. Best image quality was achieved by referencing image reconstruction to middiastole (50%-60%) for the left coronary artery, aortic root, and ascending aorta. The pulmonary arteries are best displayed during mid- to late diastole (80%). (c) RSNA, 2004

  3. Magnitude of the impact of hot flashes on sleep in perimenopausal women

    PubMed Central

    de Zambotti, Massimiliano; Colrain, Ian M.; Javitz, Harold S.; Baker, Fiona C.

    2014-01-01

    Objective To quantify the impact of objectively-recorded hot flashes on objective sleep in perimenopausal women. Design Cross-sectional study. Participants underwent 1–5 laboratory-based polysomnographic recordings for a total of 63 nights, including sternal skin conductance measures, from which 222 hot flashes were identified according to established criteria. Data were analyzed with hierarchical mixed-effect models and Spearman correlations. Setting Sleep laboratory. Patients 34 perimenopausal women (Age±SD:50.4±2.7y). Intervention None. Main Outcome Measures Perceived and polysomnographic sleep measures (sleep quality, amount of wake after sleep onset and number of awakenings). Subjective (frequency and bother) and objective (frequency and amount of hot flash-associated wake time) hot flash measures. Results Women had an average of 3.5 (95%CI:2.8–4.2, range=1– 9) objective hot flashes per night. 69.4% of hot flashes were associated with an awakening. Hot flash-associated wake time per night was, on average, 16.6 min (95%CI:10.8–22.4), which accounted for 27.2% (SD 27.1) of total wakefulness per night. Hot flash-associated wake, but not frequency, was negatively associated with sleep efficiency and positively associated with wake after sleep onset. Also, self-reported wakefulness correlated with hot flash-associated wake, suggesting that women’s estimates of wakefulness are influenced by the amount of time spent awake in association with hot flashes during the night. More perceived and bothersome hot flashes correlated with more perceived wakefulness and awakenings and more objective hot flash-associated wake time and hot flash frequency. Conclusions The presence of physiological hot flashes accounts for a significant proportion of total objective wakefulness during the night in perimenopausal women. PMID:25256933

  4. Computed Tomography of the Normal Bovine Tarsus.

    PubMed

    Hagag, U; Tawfiek, M; Brehm, W; Gerlach, K

    2016-12-01

    The objective of this study was to provide a detailed multiplanar computed tomographic (CT) anatomic reference for the bovine tarsus. The tarsal regions from twelve healthy adult cow cadavers were scanned in both soft and bone windows via a 16-slice multidetector CT scanner. Tarsi were frozen at -20 o C and sectioned to 10-mm-thick slices in transverse, dorsal and sagittal planes respecting the imaging protocol. The frozen sections were cleaned and then photographed. Anatomic structures were identified, labelled and compared with the corresponding CT images. The sagittal plane was indispensable for evaluation of bone contours, the dorsal plane was valuable in examination of the collateral ligaments, and both were beneficial for assessment of the tarsal joint articulations. CT images allowed excellent delineation between the cortex and medulla of bones, and the trabecular structure was clearly depicted. The tarsal soft tissues showed variable shades of grey, and the synovial fluid was the lowest attenuated structure. This study provided full assessment of the clinically relevant anatomic structures of the bovine tarsal joint. This technique may be of value when results from other diagnostic imaging techniques are indecisive. Images presented in this study should serve as a basic CT reference and assist in the interpretation of various bovine tarsal pathology. © 2016 Blackwell Verlag GmbH.

  5. 114. ARAI Hot cell (ARA626) Building details of fuel storage ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    114. ARA-I Hot cell (ARA-626) Building details of fuel storage pit in plan and section. Spaces shown for 20 elements. Norman Engineering Company: 961-area/SF-626-S-4. Date: January 1959. Ineel index code no. 068-0626-60-613-102752. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  6. Holding fixture for a hot stamping press

    NASA Technical Reports Server (NTRS)

    Harris, R. P. (Inventor)

    1983-01-01

    A hand held guide for manually positioning a work piece between the anvil rib and tool of a hot die stamping press is described. A groove completed by interchangeable cover plates attached at one end of the guide conforms to a cross sectional dimension common to similar workpieces and, with a force fit, retentively holds each of the workpieces.

  7. 46 CFR 126.160 - Tests and inspections during repairs or alterations, or during riveting, welding, burning, or...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... during riveting, welding, burning, or other hot work. 126.160 Section 126.160 Shipping COAST GUARD... § 126.160 Tests and inspections during repairs or alterations, or during riveting, welding, burning, or... riveting, welding, burning, or other hot work may commence. (c) Each examination must be conducted as...

  8. 16 CFR § 1505.51 - Hot surfaces.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...

  9. Shape Memory Alloy Actuator

    NASA Technical Reports Server (NTRS)

    Baumbick, Robert J. (Inventor)

    2000-01-01

    The present invention discloses and teaches a unique, remote optically controlled micro actuator particularly suitable for aerospace vehicle applications wherein hot gas, or in the alternative optical energy, is employed as the medium by which shape memory alloy elements are activated. In gas turbine powered aircraft the source of the hot gas may be the turbine engine compressor or turbine sections.

  10. Shape Memory Alloy Actuator

    NASA Technical Reports Server (NTRS)

    Baumbick, Robert J. (Inventor)

    2002-01-01

    The present invention discloses and teaches a unique, remote optically controlled micro actuator particularly suitable for aerospace vehicle applications wherein hot gas, or in the alternative optical energy, is employed as the medium by which shape memory alloy elements are activated. In gas turbine powered aircraft the source of the hot gas may be the turbine engine compressor or turbine sections.

  11. 78 FR 15703 - Certain Hot-Rolled Carbon Steel Flat Products From India, Indonesia, the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-12

    ...-835, A-549-817, A-823-811] Certain Hot-Rolled Carbon Steel Flat Products From India, Indonesia, the... steel flat products from India, Indonesia, the People's Republic of China (PRC), Taiwan, Thailand, and... steel flat products from India, Indonesia, the PRC, Taiwan, Thailand, and Ukraine, pursuant to section...

  12. 46 CFR 126.160 - Tests and inspections during repairs or alterations, or during riveting, welding, burning, or...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... during riveting, welding, burning, or other hot work. 126.160 Section 126.160 Shipping COAST GUARD... § 126.160 Tests and inspections during repairs or alterations, or during riveting, welding, burning, or... riveting, welding, burning, or other hot work may commence. (c) Each examination must be conducted as...

  13. 46 CFR 126.160 - Tests and inspections during repairs or alterations, or during riveting, welding, burning, or...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... during riveting, welding, burning, or other hot work. 126.160 Section 126.160 Shipping COAST GUARD... § 126.160 Tests and inspections during repairs or alterations, or during riveting, welding, burning, or... riveting, welding, burning, or other hot work may commence. (c) Each examination must be conducted as...

  14. 46 CFR 126.160 - Tests and inspections during repairs or alterations, or during riveting, welding, burning, or...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... during riveting, welding, burning, or other hot work. 126.160 Section 126.160 Shipping COAST GUARD... § 126.160 Tests and inspections during repairs or alterations, or during riveting, welding, burning, or... riveting, welding, burning, or other hot work may commence. (c) Each examination must be conducted as...

  15. 46 CFR 126.160 - Tests and inspections during repairs or alterations, or during riveting, welding, burning, or...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... during riveting, welding, burning, or other hot work. 126.160 Section 126.160 Shipping COAST GUARD... § 126.160 Tests and inspections during repairs or alterations, or during riveting, welding, burning, or... riveting, welding, burning, or other hot work may commence. (c) Each examination must be conducted as...

  16. Refrigerator with anti-sweat hot liquid loop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woolley, S.J.; Cushing, D.S.; Jenkins, T.E.

    A cabinet assembly for a refrigerator having a freezer compartment ontop with two top front corners, a fresh food compartment on the bottom, a mullion partition between the compartments and a hot liquid anti-sweat loop is described comprising; an outer sheet metal shell having a top panel, side panels and a front face, a brace located at each of the two top front corners of the cabinet and having two formed sections at right angles to each other and each section is formed as an inwardly open U-shaped channel having a base, a first leg and a second leg spacedmore » apart and integrally joined to the base, fastening means for rigidly attaching each of the second leg of the corner braces to the flange of the third wall of the front face, and means to secure a portion of the hot liquid anti-sweat loop to the braces.« less

  17. The impact of a single round of community mass treatment with azithromycin on disease severity and ocular Chlamydia trachomatis load in treatment-naïve trachoma-endemic island communities in West Africa.

    PubMed

    Last, Anna R; Burr, Sarah E; Harding-Esch, Emma; Cassama, Eunice; Nabicassa, Meno; Roberts, Chrissy H; Mabey, David C W; Holland, Martin J; Bailey, Robin L

    2017-12-28

    Trachoma, a neglected tropical disease, is caused by ocular infection with Chlamydia trachomatis (Ct). The World Health Organization (WHO) recommends three annual rounds of community mass drug treatment with azithromycin (MDA) if the prevalence of follicular trachoma in 1-9 year olds (TF 1-9 ) exceeds 10% at district level to achieve an elimination target of district-level TF 1-9 below 5% after. To evaluate this strategy in treatment-naïve trachoma-endemic island communities in Guinea Bissau, we conducted a cross-sectional population-based trachoma survey on four islands. The upper tarsal conjunctivae of each participant were clinically assessed for trachoma and conjunctival swabs were obtained (n = 1507). We used a droplet digital PCR assay to detect Ct infection and estimate bacterial load. We visited the same households during a second cross-sectional survey and repeated the ocular examination and obtained conjunctival swabs from these households one year after MDA (n = 1029). Pre-MDA TF 1-9 was 22.0% (136/618). Overall Ct infection prevalence (CtI) was 18.6% (25.4% in 1-9 year olds). Post-MDA (estimated coverage 70%), TF 1-9 and CtI were significantly reduced (7.4% (29/394, P < 0.001) and 3.3% (34/1029, P < 0.001) (6.6% in 1-9 year olds, P < 0.001), respectively. Median ocular Ct load was reduced from 2038 to 384 copies/swab (P < 0.001). Following MDA cases of Ct infection were highly clustered (Moran's I 0.27, P < 0.001), with fewer clusters of Ct infection overall, fewer clusters of cases with high load infections and less severe disease. Despite a significant reduction in the number of clusters of Ct infection, mean Ct load, disease severity and presence of clusters of cases of high load Ct infection suggesting the beginning of trachoma control in isolated island communities, following a single round of MDA we demonstrate that transmission is still ongoing. These detailed data are useful in understanding the epidemiology of ocular Ct infection in the context of MDA and the tools employed may have utility in determining trachoma elimination and surveillance activities in similar settings.

  18. CASMO5/TSUNAMI-3D spent nuclear fuel reactivity uncertainty analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrer, R.; Rhodes, J.; Smith, K.

    2012-07-01

    The CASMO5 lattice physics code is used in conjunction with the TSUNAMI-3D sequence in ORNL's SCALE 6 code system to estimate the uncertainties in hot-to-cold reactivity changes due to cross-section uncertainty for PWR assemblies at various burnup points. The goal of the analysis is to establish the multiplication factor uncertainty similarity between various fuel assemblies at different conditions in a quantifiable manner and to obtain a bound on the hot-to-cold reactivity uncertainty over the various assembly types and burnup attributed to fundamental cross-section data uncertainty. (authors)

  19. 33 CFR 100.102 - Great Connecticut River Raft Race, Middletown, CT.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Great Connecticut River Raft Race, Middletown, CT. 100.102 Section 100.102 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.102 Great Connecticut River...

  20. 33 CFR 100.102 - Great Connecticut River Raft Race, Middletown, CT.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Great Connecticut River Raft Race... Raft Race, Middletown, CT. (a) Regulated Area. That section of the Connecticut River between Dart.... (1) The Coast Guard patrol commander may delay, modify, or cancel the race as conditions or...

  1. Histologic evaluation of autogenous connective tissue and acellular dermal matrix grafts in humans.

    PubMed

    Cummings, Lewis C; Kaldahl, Wayne B; Allen, Edward P

    2005-02-01

    The clinical success of root coverage with autogenous connective tissue (CT) or acellular dermal matrix (ADM) has been well documented. However, limited histological results of CT grafts have been reported, and a case report of a human block section has been published documenting an ADM graft. The purpose of this study is to document the histological results of CT grafts, ADM grafts, and coronally advanced flaps to cover denuded roots in humans. This study included four patients previously treatment planned for extractions of three or more anterior teeth. Three teeth in each patient were selected and randomly designated to receive either a CT or ADM graft beneath a coronally advanced flap (tests) or coronally advanced flap alone (control). Six months postoperatively block section extractions were performed and the teeth processed for histologic evaluation with hematoxylin-eosin and Verhoeff's stains. Histologically, both the CT and ADM were well incorporated within the recipient tissues. New fibroblasts, vascular elements, and collagen were present throughout the ADM, while retention of the transplanted elastic fibers was apparent. No effect on the keratinization or connective tissue organization of the overlying alveolar mucosa was evident with either graft. For both materials, areas of cemental deposition were present within the root notches, the alveolar bone was essentially unaffected, and the attachments to the root surfaces were similar. Although CT and ADM have a slightly different histological appearance, both can successfully be used to cover denuded roots with similar attachments and no adverse healing.

  2. A “loop” shape descriptor and its application to automated segmentation of airways from CT scans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pu, Jiantao; Jin, Chenwang, E-mail: jcw76@163.com; Yu, Nan

    2015-06-15

    Purpose: A novel shape descriptor is presented to aid an automated identification of the airways depicted on computed tomography (CT) images. Methods: Instead of simplifying the tubular characteristic of the airways as an ideal mathematical cylindrical or circular shape, the proposed “loop” shape descriptor exploits the fact that the cross sections of any tubular structure (regardless of its regularity) always appear as a loop. In implementation, the authors first reconstruct the anatomical structures in volumetric CT as a three-dimensional surface model using the classical marching cubes algorithm. Then, the loop descriptor is applied to locate the airways with a concavemore » loop cross section. To deal with the variation of the airway walls in density as depicted on CT images, a multiple threshold strategy is proposed. A publicly available chest CT database consisting of 20 CT scans, which was designed specifically for evaluating an airway segmentation algorithm, was used for quantitative performance assessment. Measures, including length, branch count, and generations, were computed under the aid of a skeletonization operation. Results: For the test dataset, the airway length ranged from 64.6 to 429.8 cm, the generation ranged from 7 to 11, and the branch number ranged from 48 to 312. These results were comparable to the performance of the state-of-the-art algorithms validated on the same dataset. Conclusions: The authors’ quantitative experiment demonstrated the feasibility and reliability of the developed shape descriptor in identifying lung airways.« less

  3. [Cutaneous lesions during hot-tub hypersensitivity pneumonitis: Pseudomonas folliculitis ?

    PubMed

    Sokolowsky, N; Rolland, L; Vandenhende, M-A; Colin, J-Y; Laurent, F; Morlat, P; Bonnet, F; Beylot-Barry, M

    2017-04-01

    Interstitial lung disease, cutaneous rash and elevated serum angiotensin converting enzyme (ACE) may suggest diagnoses other than sarcoidosis. A 58-year-old man had presented dyspnoea for 2 years with increased angiotensin-converting enzyme, as well as an interstitial syndrome and micronodules. The possibility of sarcoidosis was raised. Systemic corticosteroids resulted in improvement of the dyspnoea although it recurred on dose reduction. We noted fluctuating eczematous macules of the limbs with a histology of aspecific folliculitis. The identification of Mycobacterium avium complex (MAC) in the bronchoalveolar wash prompted us to initiate antimycobacterial therapy, but this was to no avail. Review of the CT-scan and questioning of the patient (daily use of a Jacuzzi for 7 years) resulted in diagnosis of hypersensitivity pneumonitis due to MAC. The cutaneous lesions were taken to indicate "hot tub folliculitis". Discontinuation of hot-tub use and a short course of oral corticosteroids resulted in healing within 4 months, with no recurrence at 2 years. HTL is a form of hypersensitivity pneumonitis due to the presence of MAC in the water of Jacuzzis. This condition regresses spontaneously without treatment on discontinuation of Jacuzzi use. Hot-tub folliculitis due to Pseudomonas aeruginosa (PA) presents as macules and papules on covered skin areas (swimsuit) within 48hours of bathing and often declines within 2 weeks. Our case is original as regards the concomitant lung and cutaneous involvement associated with Jacuzzi use, with an immunoallergic mechanism for the MAC and probably an infectious mechanism for the PA. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  4. Hot Spot and Whole-Tumor Enumeration of CD8+ Tumor-Infiltrating Lymphocytes Utilizing Digital Image Analysis Is Prognostic in Triple-Negative Breast Cancer.

    PubMed

    McIntire, Patrick J; Irshaid, Lina; Liu, Yifang; Chen, Zhengming; Menken, Faith; Nowak, Eugene; Shin, Sandra J; Ginter, Paula S

    2018-05-07

    CD8 + tumor-infiltrating lymphocytes (TILs) have emerged as a prognostic indicator in triple-negative breast cancer (TNBC). There is debate surrounding the prognostic value of hot spots for CD8 + TIL enumeration. We compared hot spot versus whole-tumor CD8 + TIL enumeration in prognosticating TNBC using immunohistochemistry on whole tissue sections and quantification by digital image analysis (Halo imaging analysis software; Indica Labs, Corrales, NM). A wide range of clinically relevant hot spot sizes was evaluated. CD8 + TIL enumeration was independently statistically significant for all hot spot sizes and whole-tumor annotations for disease-free survival by multivariate analysis. A 10× objective (2.2 mm diameter) hot spot was found to correlate significantly with overall survival (P = .04), while the remaining hot spots and whole-tumor CD8 + TIL enumeration did not (P > .05). Statistical significance was not demonstrated when comparing between hot spots and whole-tumor annotations, as the groups had overlapping confidence intervals. CD8 + TIL hot spot enumeration is equivalent to whole-tumor enumeration for prognostication in TNBC and may serve as a good alternative methodology in future studies and clinical practice. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Heat transfer to two-phase air/water mixtures flowing in small tubes with inlet disequilibrium

    NASA Technical Reports Server (NTRS)

    Janssen, J. M.; Florschuetz, L. W.; Fiszdon, J. P.

    1986-01-01

    The cooling of gas turbine components was the subject of considerable research. The problem is difficult because the available coolant, compressor bleed air, is itself quite hot and has relatively poor thermophysical properties for a coolant. Injecting liquid water to evaporatively cool the air prior to its contact with the hot components was proposed and studied, particularly as a method of cooling for contingency power applications. Injection of a small quantity of cold liquid water into a relatively hot coolant air stream such that evaporation of the liquid is still in process when the coolant contacts the hot component was studied. No approach was found whereby heat transfer characteristics could be confidently predicted for such a case based solely on prior studies. It was not clear whether disequilibrium between phases at the inlet to the hot component section would improve cooling relative to that obtained where equilibrium was established prior to contact with the hot surface.

  6. Performance of Recycled Hot Mix Asphalt Mixtures

    DOT National Transportation Integrated Search

    1995-05-01

    This research project was undertaken to evaluate the performance of recycled pavements in comparison to virgin (control) asphalt pavements. Five projects, each consisting of a recycled section and a control section, were subjected to detailed evaluat...

  7. Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.

    PubMed

    Wuest, W; May, M S; Brand, M; Bayerl, N; Krauss, A; Uder, M; Lell, M

    2015-10-01

    Metal artifacts from dental fillings and other devices degrade image quality and may compromise the detection and evaluation of lesions in the oral cavity and oropharynx by CT. The aim of this study was to evaluate the effect of iterative metal artifact reduction on CT of the oral cavity and oropharynx. Data from 50 consecutive patients with metal artifacts from dental hardware were reconstructed with standard filtered back-projection, linear interpolation metal artifact reduction (LIMAR), and iterative metal artifact reduction. The image quality of sections that contained metal was analyzed for the severity of artifacts and diagnostic value. A total of 455 sections (mean ± standard deviation, 9.1 ± 4.1 sections per patient) contained metal and were evaluated with each reconstruction method. Sections without metal were not affected by the algorithms and demonstrated image quality identical to each other. Of these sections, 38% were considered nondiagnostic with filtered back-projection, 31% with LIMAR, and only 7% with iterative metal artifact reduction. Thirty-three percent of the sections had poor image quality with filtered back-projection, 46% with LIMAR, and 10% with iterative metal artifact reduction. Thirteen percent of the sections with filtered back-projection, 17% with LIMAR, and 22% with iterative metal artifact reduction were of moderate image quality, 16% of the sections with filtered back-projection, 5% with LIMAR, and 30% with iterative metal artifact reduction were of good image quality, and 1% of the sections with LIMAR and 31% with iterative metal artifact reduction were of excellent image quality. Iterative metal artifact reduction yields the highest image quality in comparison with filtered back-projection and linear interpolation metal artifact reduction in patients with metal hardware in the head and neck area. © 2015 by American Journal of Neuroradiology.

  8. Treatment response assessment of radiofrequency ablation for hepatocellular carcinoma: usefulness of virtual CT sonography with magnetic navigation.

    PubMed

    Minami, Yasunori; Kitai, Satoshi; Kudo, Masatoshi

    2012-03-01

    Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. Sixty-one patients with 88 HCCs measuring 0.5-1.3 cm (mean±SD, 1.0±0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1-5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P=0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P=0.13). The safety margin should be overestimated on axial CT images in 8 nodules. Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. Influence of the autonomic nervous system on calcium homeostasis in the rat.

    PubMed

    Stern, J E; Cardinali, D P

    1994-01-01

    The local surgical manipulation of sympathetic and parasympathetic nerves innervating the thyroid-parathyroid territory was employed to search for the existence of a peripheral neuroendocrine link controlling parathyroid hormone (PTH) and calcitonin (CT) release. From 8 to 24 h after superior cervical ganglionectomy (SCGx), at the time of wallerian degeneration of thyroid-parathyroid sympathetic nerve terminals, an alpha-adrenergic inhibition, together with a minor beta-adrenergic stimulation, of hypercalcemia-induced CT release, and an alpha-adrenoceptor inhibition of hypocalcemia-induced PTH release were found. In chronically SCGx rats PTH response to EDTA was slower, and after CaCl2 injection, serum calcium attained higher levels in face of normal CT levels. SCGx blocked the PTH increase found in sham-operated rats stressed by a subcutaneous injection of turpentine oil, but did not affect the greater response to EDTA. The higher hypocalcemia seen after turpentine oil was no longer observed in SCGx rats. The effects of turpentine oil stress on calcium and CT responses to a bolus injection of CaCl2 persisted in rats subjected to SCGx 14 days earlier. Interruption of thyroid-parathyroid parasympathetic input conveyed by the thyroid nerves (TN) and the inferior laryngeal nerves (ILN) caused a fall in total serum calcium, an increase of PTH levels and a decrease of CT levels, when measured 10 days after surgery. Greater responses of serum CT and PTH were detected in TN-sectioned, and in TN- or ILN-sectioned rats, respectively. Physiological concentrations of CT decreased, and those of PTH increased, in vitro cholinergic activity in rat SCG, measured as specific choline uptake, and acetylcholine synthesis and release. The results indicate that cervical autonomic nerves constitute a pathway through which the brain modulates calcium homeostasis.

  10. 3-D microstructure of olivine in complex geological materials reconstructed by correlative X-ray μ-CT and EBSD analyses.

    PubMed

    Kahl, W-A; Dilissen, N; Hidas, K; Garrido, C J; López-Sánchez-Vizcaíno, V; Román-Alpiste, M J

    2017-11-01

    We reconstruct the 3-D microstructure of centimetre-sized olivine crystals in rocks from the Almirez ultramafic massif (SE Spain) using combined X-ray micro computed tomography (μ-CT) and electron backscatter diffraction (EBSD). The semidestructive sample treatment involves geographically oriented drill pressing of rocks and preparation of oriented thin sections for EBSD from the μ-CT scanned cores. The μ-CT results show that the mean intercept length (MIL) analyses provide reliable information on the shape preferred orientation (SPO) of texturally different olivine groups. We show that statistical interpretation of crystal preferred orientation (CPO) and SPO of olivine becomes feasible because the highest densities of the distribution of main olivine crystal axes from EBSD are aligned with the three axes of the 3-D ellipsoid calculated from the MIL analyses from μ-CT. From EBSD data we distinguish multiple CPO groups and by locating the thin sections within the μ-CT volume, we assign SPO to the corresponding olivine crystal aggregates, which confirm the results of statistical comparison. We demonstrate that the limitations of both methods (i.e. no crystal orientation data in μ-CT and no spatial information in EBSD) can be overcome, and the 3-D orientation of the crystallographic axes of olivines from different orientation groups can be successfully correlated with the crystal shapes of representative olivine grains. Through this approach one can establish the link among geological structures, macrostructure, fabric and 3-D SPO-CPO relationship at the hand specimen scale even in complex, coarse-grained geomaterials. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  11. Three-dimensional observation of an helical hot structure during a sawtooth crash in the WT-3 tokamak.

    PubMed

    Yamaguchi, S; Igami, H; Tanaka, H; Maekawa, T

    2004-07-23

    Sawtooth crashes in an Ohmically heated plasma in the WT-3 tokamak have been observed by using soft x-ray computer tomography at three different poloidal cross sections around the torus. Initially, collapsing proceeds slowly with keeping the helical structure of an m = 1/n = 1 hot core around the torus. It accelerates as the helical hot structure is strongly deformed and fades away in the manner that the hot core at the high field side becomes obscure and disappears, while that at the low field side is deformed into a thin crescent aligned along the inversion circle, which survives even at the completion of the crash. Copyright 2004 The American Physical Society

  12. Accuracy of limited four-slice CT-scan in diagnosis of chronic rhinosinusitis.

    PubMed

    Zojaji, R; Nekooei, S; Naghibi, S; Mazloum Farsi Baf, M; Jalilian, R; Masoomi, M

    2015-12-01

    Chronic rhinosinusitis (CRS) is a common chronic health condition worldwide. Standard CT-scan is the method of choice for diagnosis of CRS but its high price and considerable radiation exposure have limited its application. The main goal of this study was to evaluate the accuracy of limited four-slice coronal CT-scan in the diagnosis of CRS. This cross-sectional study was conducted on 46 patients with CRS, for one year, based on American Society of Head and Neck Surgery criteria. All patients received the preoperative standard and four-slice CT-scans, after which endoscopic sinus surgery was performed. Findings of four-slice CT-scans were compared with those of conventional CT-scan and the sensitivity and specificity of four-slice CT-scan and its agreement with conventional CT-scan was calculated. In this study, 46 patients including 32 males (69.6%) and 14 females (30.46%) with a mean age of 33 and standard deviation of 9 years, were evaluated. Sensitivity and specificity of four-slice CT-scan were 97.5% and 100%, respectively. Also, positive predictive value (PPV) and negative predictive value (NPV) of four-slice CT was 100% and 85.71%, respectively. There was a strong agreement between four-slice CT and conventional CT findings. Considering the high sensitivity and specificity of four-slice CT-scan and strong agreement with conventional CT-scan in the diagnosis of CRS and the lower radiation exposure and cost, application of this method is suggested for both diagnosis and treatment follow-up in CRS. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  13. Radiation exposure in whole body CT screening.

    PubMed

    Suresh, Pamidighantam; Ratnam, S V; Rao, K V J

    2011-04-01

    Using a technology that "takes a look" at people's insides and promises early warnings of cancer, cardiac disease, and other abnormalities, clinics and medical imaging facilities nationwide are touting a new service for health conscious people: "Whole body CT screening" this typically involves scanning the body from the chin to below the hips with a form of x-ray imaging that produces cross-sectional images. In USA direct-to-consumer marketing of whole body CT is occurring today in many metropolitan areas. Free standing CT screening centres are being sited in shopping malls and other high density public areas, and these centres are being advertised in the electronic and print media. In this context the present article discussed the pros and cons of having such centres in India with the advent of multislice CT leading to fast scan times.

  14. 76 FR 28419 - Certain Hot-Rolled Carbon Steel Flat Products From India: Notice of Extension of Time Limit for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-533-820] Certain Hot-Rolled Carbon...-rolled carbon steel flat products from India for the period December 1, 2008, through November 30, 2009... September 14, 2010, in accordance with section 751(a)(3)(A) of the Tariff Act of 1930, as amended (the Act...

  15. 36 CFR 21.3 - Use of thermal water.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false Use of thermal water. 21.3 Section 21.3 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR HOT SPRINGS NATIONAL PARK; BATHHOUSE REGULATIONS § 21.3 Use of thermal water. (a) The use of the thermal waters of Hot Springs National Park, for...

  16. 36 CFR 21.3 - Use of thermal water.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 1 2014-07-01 2014-07-01 false Use of thermal water. 21.3 Section 21.3 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR HOT SPRINGS NATIONAL PARK; BATHHOUSE REGULATIONS § 21.3 Use of thermal water. (a) The use of the thermal waters of Hot Springs National Park, for...

  17. Automated continuous quantitative measurement of proximal airways on dynamic ventilation CT: initial experience using an ex vivo porcine lung phantom.

    PubMed

    Yamashiro, Tsuneo; Tsubakimoto, Maho; Nagatani, Yukihiro; Moriya, Hiroshi; Sakuma, Kotaro; Tsukagoshi, Shinsuke; Inokawa, Hiroyasu; Kimoto, Tatsuya; Teramoto, Ryuichi; Murayama, Sadayuki

    2015-01-01

    The purpose of this study was to evaluate the feasibility of continuous quantitative measurement of the proximal airways, using dynamic ventilation computed tomography (CT) and our research software. A porcine lung that was removed during meat processing was ventilated inside a chest phantom by a negative pressure cylinder (eight times per minute). This chest phantom with imitated respiratory movement was scanned by a 320-row area-detector CT scanner for approximately 9 seconds as dynamic ventilatory scanning. Obtained volume data were reconstructed every 0.35 seconds (total 8.4 seconds with 24 frames) as three-dimensional images and stored in our research software. The software automatically traced a designated airway point in all frames and measured the cross-sectional luminal area and wall area percent (WA%). The cross-sectional luminal area and WA% of the trachea and right main bronchus (RMB) were measured for this study. Two radiologists evaluated the traceability of all measurable airway points of the trachea and RMB using a three-point scale. It was judged that the software satisfactorily traced airway points throughout the dynamic ventilation CT (mean score, 2.64 at the trachea and 2.84 at the RMB). From the maximum inspiratory frame to the maximum expiratory frame, the cross-sectional luminal area of the trachea decreased 17.7% and that of the RMB 29.0%, whereas the WA% of the trachea increased 6.6% and that of the RMB 11.1%. It is feasible to measure airway dimensions automatically at designated points on dynamic ventilation CT using research software. This technique can be applied to various airway and obstructive diseases.

  18. Automated assessment of bone changes in cross-sectional micro-CT studies of murine experimental osteoarthritis.

    PubMed

    Das Neves Borges, Patricia; Vincent, Tonia L; Marenzana, Massimo

    2017-01-01

    The degradation of articular cartilage, which characterises osteoarthritis (OA), is usually paired with excessive bone remodelling, including subchondral bone sclerosis, cysts, and osteophyte formation. Experimental models of OA are widely used to investigate pathogenesis, yet few validated methodologies for assessing periarticular bone morphology exist and quantitative measurements are limited by manual segmentation of micro-CT scans. The aim of this work was to chart the temporal changes in periarticular bone in murine OA by novel, automated micro-CT methods. OA was induced by destabilisation of the medial meniscus (DMM) in 10-week old male mice and disease assessed cross-sectionally from 1- to 20-weeks post-surgery. A novel approach was developed to automatically segment subchondral bone compartments into plate and trabecular bone in micro-CT scans of tibial epiphyses. Osteophyte volume, as assessed by shape differences using 3D image registration, and by measuring total epiphyseal volume was performed. Significant linear and volumetric structural modifications in subchondral bone compartments and osteophytes were measured from 4-weeks post-surgery and showed progressive changes at all time points; by 20 weeks, medial subchondral bone plate thickness increased by 160±19.5 μm and the medial osteophyte grew by 0.124±0.028 μm3. Excellent agreement was found when automated measurements were compared with manual assessments. Our automated methods for assessing bone changes in murine periarticular bone are rapid, quantitative, and highly accurate, and promise to be a useful tool in future preclinical studies of OA progression and treatment. The current approaches were developed specifically for cross-sectional micro-CT studies but could be applied to longitudinal studies.

  19. Automated assessment of bone changes in cross-sectional micro-CT studies of murine experimental osteoarthritis

    PubMed Central

    Vincent, Tonia L.; Marenzana, Massimo

    2017-01-01

    Objective The degradation of articular cartilage, which characterises osteoarthritis (OA), is usually paired with excessive bone remodelling, including subchondral bone sclerosis, cysts, and osteophyte formation. Experimental models of OA are widely used to investigate pathogenesis, yet few validated methodologies for assessing periarticular bone morphology exist and quantitative measurements are limited by manual segmentation of micro-CT scans. The aim of this work was to chart the temporal changes in periarticular bone in murine OA by novel, automated micro-CT methods. Methods OA was induced by destabilisation of the medial meniscus (DMM) in 10-week old male mice and disease assessed cross-sectionally from 1- to 20-weeks post-surgery. A novel approach was developed to automatically segment subchondral bone compartments into plate and trabecular bone in micro-CT scans of tibial epiphyses. Osteophyte volume, as assessed by shape differences using 3D image registration, and by measuring total epiphyseal volume was performed. Results Significant linear and volumetric structural modifications in subchondral bone compartments and osteophytes were measured from 4-weeks post-surgery and showed progressive changes at all time points; by 20 weeks, medial subchondral bone plate thickness increased by 160±19.5 μm and the medial osteophyte grew by 0.124±0.028 μm3. Excellent agreement was found when automated measurements were compared with manual assessments. Conclusion Our automated methods for assessing bone changes in murine periarticular bone are rapid, quantitative, and highly accurate, and promise to be a useful tool in future preclinical studies of OA progression and treatment. The current approaches were developed specifically for cross-sectional micro-CT studies but could be applied to longitudinal studies. PMID:28334010

  20. Comparison of image quality and radiation dose between fixed tube current and combined automatic tube current modulation in craniocervical CT angiography.

    PubMed

    Lee, E J; Lee, S K; Agid, R; Howard, P; Bae, J M; terBrugge, K

    2009-10-01

    The combined automatic tube current modulation (ATCM) technique adapts and modulates the x-ray tube current in the x-y-z axis according to the patient's individual anatomy. We compared image quality and radiation dose of the combined ATCM technique with those of a fixed tube current (FTC) technique in craniocervical CT angiography performed with a 64-section multidetector row CT (MDCT) system. A retrospective review of craniocervical CT angiograms (CTAs) by using combined ATCM (n = 25) and FTC techniques (n = 25) was performed. Other CTA parameters, such as kilovolt (peak), matrix size, FOV, section thickness, pitch, contrast agent, and contrast injection techniques, were held constant. We recorded objective image noise in the muscles at 2 anatomic levels: radiation exposure doses (CT dose index volume and dose-length product); and subjective image quality parameters, such as vascular delineation of various arterial vessels, visibility of small arterial detail, image artifacts, and certainty of diagnosis. The Mann-Whitney U test was used for statistical analysis. No significant difference was detected in subjective image quality parameters between the FTC and combined ATCM techniques. Most subjects in both study groups (49/50, 98%) had acceptable subjective artifacts. The objective image noise values at shoulder level did not show a significant difference, but the noise value at the upper neck was higher with the combined ATCM (P < .05) technique. Significant reduction in radiation dose (18% reduction) was noted with the combined ATCM technique (P < .05). The combined ATCM technique for craniocervical CTA performed at 64-section MDCT substantially reduced radiation exposure dose but maintained diagnostic image quality.

  1. 3D ECG- and respiratory-gated non-contrast-enhanced (CE) perfusion MRI for postoperative lung function prediction in non-small-cell lung cancer patients: A comparison with thin-section quantitative computed tomography, dynamic CE-perfusion MRI, and perfusion scan.

    PubMed

    Ohno, Yoshiharu; Seki, Shinichiro; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Takenaka, Daisuke; Kassai, Yoshimori; Yui, Masao; Sugimura, Kazuro

    2015-08-01

    To compare predictive capabilities of non-contrast-enhanced (CE)- and dynamic CE-perfusion MRIs, thin-section multidetector computed tomography (CT) (MDCT), and perfusion scan for postoperative lung function in non-small cell lung cancer (NSCLC) patients. Sixty consecutive pathologically diagnosed NSCLC patients were included and prospectively underwent thin-section MDCT, non-CE-, and dynamic CE-perfusion MRIs and perfusion scan, and had their pre- and postoperative forced expiratory volume in one second (FEV1 ) measured. Postoperative percent FEV1 (po%FEV1 ) was then predicted from the fractional lung volume determined on semiquantitatively assessed non-CE- and dynamic CE-perfusion MRIs, from the functional lung volumes determined on quantitative CT, from the number of segments observed on qualitative CT, and from uptakes detected on perfusion scans within total and resected lungs. Predicted po%FEV1 s were then correlated with actual po%FEV1 s, which were %FEV1 s measured postoperatively. The limits of agreement were also determined. All predicted po%FEV1 s showed significant correlation (0.73 ≤ r ≤ 0.93, P < 0.0001) and limits of agreement with actual po%FEV1 (non-CE-perfusion MRI: 0.3 ± 10.0%, dynamic CE-perfusion MRI: 1.0 ± 10.8%, perfusion scan: 2.2 ± 14.1%, quantitative CT: 1.2 ± 9.0%, qualitative CT: 1.5 ± 10.2%). Non-CE-perfusion MRI may be able to predict postoperative lung function more accurately than qualitatively assessed MDCT and perfusion scan. © 2014 Wiley Periodicals, Inc.

  2. NASA Tech Briefs, December 1998. Volume 22, No. 12

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Topics include: special coverage section on design and analysis software, and sections on electronic components and circuits, electronic systems, software, materials, mechanics, machinery/automation, manufacturing/fabrication, physical sciences, and special sections of Photonics Tech Briefs, Motion Control Tech briefs and a Hot Technology File 1999 Resource Guide.

  3. 40 CFR Appendix A to Part 97 - Final Section 126 Rule: EGU Allocations, 2004-2007

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... W H WEATHERSPOON 2716 CT-2 3 NC W H WEATHERSPOON 2716 CT-3 2 NC W H WEATHERSPOON 2716 CT-4 4 NJ B L... KY COOPER 1384 1 183 KY COOPER 1384 2 367 KY DALE 1385 3 161 KY DALE 1385 4 158 KY E W BROWN 1355 1 193 KY E W BROWN 1355 10 37 KY E W BROWN 1355 2 317 KY E W BROWN 1355 3 863 KY E W BROWN 1355 8 34 KY...

  4. IRIS family of IRCCD thermal imagers integrating long-life cryogenic coolers, sophisticated algorithms for image enhancement, and hot points detection

    NASA Astrophysics Data System (ADS)

    Dupuy, Pascal; Harter, Jean

    1995-09-01

    Iris is a modular infrared thermal image developed by SAGEM since 1988, based on a 288 by 4 IRCCD detector. The first section of the presentation gives a description of the different modules of the IRIS thermal imager and their evolution in recent years. The second section covers the description of the major evolution, namely the integrated detector cooler assembly (IDCA), using a SOFRADIR 288 by 4 detector and a SAGEM microcooler, now integrated in the IRIS thermal imagers. The third section gives the description of two functions integrated in the IRIS thermal imager: (1) image enhancement, using a digital convolution filter, and (2) automatic hot points detection and tracking, offering an assistance to surveillance and automatic detection. The last section presents several programs for navy, air forces, and land applications for which IRIS has already been selected and achieved.

  5. Thoracic endometriosis with catamenial haemoptysis and pneumothorax: computed tomography findings and long-term follow-up after danazol treatment

    PubMed Central

    Suwatanapongched, Thitiporn; Boonsarngsuk, Viboon; Amornputtisathaporn, Naparat; Leelachaikul, Paisan

    2015-01-01

    Thoracic endometriosis (TE) is an uncommon disorder affecting women of childbearing age. We herein report clinical and thin-section computed tomography (CT) findings of two cases, in which one woman presented with catamenial haemoptysis (CH) alone and another woman presented with bilateral catamenial pneumothoraces (CP) coinciding with CH, a rare manifestation of TE. The dynamic changes demonstrated on thin-section chest CT performed during and after menses led to accurate localisation and presumptive diagnosis of TE in both patients. Following danazol treatment, the patient with CH alone had a complete cure, while the patient with CP and CH had an incomplete cure and required long-term danazol treatment. We discuss the role of imaging studies in TE, with an emphasis on the appropriate timing and scanning technique of chest CT in women presenting with CH, potential mechanisms, treatment and patient outcomes. PMID:26243981

  6. A Survey of Attitudes towards Critical Thinking among Hong Kong Secondary School Teachers: Implications for Policy Change

    ERIC Educational Resources Information Center

    Stapleton, Paul

    2011-01-01

    The term "critical thinking" (CT) is frequently found in educational policy documents in sections outlining curriculum goals. Despite this frequency, however, precise understandings among teachers of what CT really means are lacking. In this study, 72 high school teachers in Hong Kong were surveyed and interviewed on their beliefs about…

  7. Cricothyroid muscle and thyroarytenoid muscle dominance in vocal register control: preliminary results.

    PubMed

    Kochis-Jennings, Karen Ann; Finnegan, Eileen M; Hoffman, Henry T; Jaiswal, Sanyukta; Hull, Darcey

    2014-09-01

    Headmix and head registers use cricothyroid (CT) muscle dominant voicing, whereas chest and chestmix registers use thyroarytenoid (TA) muscle dominant voicing. Cross-sectional study. CT and TA electromyographic data obtained from five untrained singers and two trained singers were analyzed to determine CT and TA muscle dominance as a function of register. Simultaneous recordings of TA and CT muscle activity and audio were obtained during production of pitch glides and a variety of midrange and upper pitches in chest, chestmix, headmix, and head registers. TA dominant phonation was only observed for chest productions and headmix/head register productions below 300 Hz. All phonation above 300 Hz, regardless of register, showed CT:TA muscle activity ratios that were CT dominant or close to 1, indicating nearly equal CT and TA muscle activity. This was true for all subjects on all vocal tasks. For the subjects sampled in this study, pitch level appeared to have a greater effect on TA and CT muscle dominance than vocal register. Preliminary findings regarding CT and TA dominance and register control do not support the assumption that all chest and chestmix production has greater TA muscle activity than CT muscle activity or that all headmix and head production require greater CT muscle activity than TA muscle activity. The data indicate that pitch level may play a greater role in determining TA and CT dominance than register. Copyright © 2014 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  8. Intraindividual Comparison of 18F-PSMA-1007 PET/CT, Multiparametric MRI, and Radical Prostatectomy Specimens in Patients with Primary Prostate Cancer: A Retrospective, Proof-of-Concept Study.

    PubMed

    Kesch, Claudia; Vinsensia, Maria; Radtke, Jan P; Schlemmer, Heinz P; Heller, Martina; Ellert, Elena; Holland-Letz, Tim; Duensing, Stefan; Grabe, Nils; Afshar-Oromieh, Ali; Wieczorek, Kathrin; Schäfer, Martin; Neels, Oliver C; Cardinale, Jens; Kratochwil, Clemens; Hohenfellner, Markus; Kopka, Klaus; Haberkorn, Uwe; Hadaschik, Boris A; Giesel, Frederik L

    2017-11-01

    68 Ga-prostate-specific membrane antigen (PSMA)-11 PET/CT represents an advanced method for the staging of primary prostate cancer (PCa) and diagnosis of recurrent or metastatic PCa. However, because of the narrow availability of 68 Ga the development of alternative tracers is of high interest. The objective of this study was to examine the value of the new PET tracer 18 F-PSMA-1007 for the staging of local disease by comparing it with multiparametric MRI (mpMRI) and radical prostatectomy (RP) histopathology. Methods: In 2016, 18 F-PSMA-1007 PET/CT was performed in 10 men with biopsy-confirmed high-risk PCa. Nine patients underwent mpMRI in the process of primary diagnosis. Consecutively, RP was performed in all 10 men. Agreement analysis was performed retrospectively. PSMA staining was added for representative sections in RP specimen slices. Localization and agreement analysis of 18 F-PSMA-1007 PET/CT, mpMRI, and RP specimens was performed by dividing the prostate into 38 sections as described in the prostate imaging reporting and data system (PI-RADS) (version 2). Sensitivity, specificity, positive predictive values, negative predictive values (NPVs), and accuracy were calculated for total and near-total agreement. Results: 18 F-PSMA-1007 PET/CT had an NPV of 68% and an accuracy of 75%, and mpMRI had an NPV of 88% and an accuracy of 73% for total agreement. Near-total agreement analysis resulted in an NPV of 91% and an accuracy of 93% for 18 F-PSMA-1007 PET/CT and 91% and 87% for mpMRI, respectively. Retrospective combination of mpMRI and PET/CT had an accuracy of 81% for total and 93% for near-total agreement. Conclusion: Comparison with RP histopathology demonstrates that 18 F-PSMA-1007 PET/CT is promising for accurate local staging of PCa. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  9. Alcohol-related hospitalisations of trauma patients in Southern Taiwan: a cross-sectional study based on a trauma registry system

    PubMed Central

    Rau, Cheng-Shyuan; Liu, Hang-Tsung; Hsu, Shiun-Yuan; Cho, Tzu-Yu; Hsieh, Ching-Hua

    2014-01-01

    Objectives To provide an overview of the demographic characteristics of patients with positive blood alcohol concentration (BAC) and to investigate the performance of brain CT scans in these patients. Design Cross-sectional study. Setting Taiwan. Participants 2192 patients who had undergone a test for blood alcohol of 13 233 patients registered in the Trauma Registry System between 1 January 2009 and 31 December 2012. A BAC level of 50 mg/dL was defined as the cut-off value. Detailed information was retrieved from the patients with positive BAC (n=793) and was compared with information from those with a negative BAC (n=1399). Main outcome measures Glasgow Coma Scale (GCS) and Injury Severity Score (ISS) as well as the performance and findings of obtained brain CT scans. Results Patients with positive BAC had a higher rate of face injury, but a lower GCS score, a lower rate of head and neck injury, a lower ISS and New Injury Severity Score. Alcohol use was associated with a shorter length of hospital stay (8.6 vs 11.4 days, p=0.000) in patients with an ISS of <16. Of 496 patients with positive BAC who underwent brain CT, 164 (33.1%) showed positive findings on CT scan. In contrast, of 891 patients with negative BAC who underwent brain CT, 389 (43.7%) had positive findings on CT scan. The lower percentage of positive CT scan findings in patients with positive BAC was particularly evident in patients with an ISS <16 (18.0% vs 28.8%, p=0.001). Conclusions Patients who consumed alcohol tended to have a low GCS score and injuries that were less severe. However, given the significantly low percentage of positive findings, brain CT might be overused in these patients with less severe injuries. PMID:25361838

  10. Ultrastructure and synaptic organization of the spinal accessory nucleus of the rat.

    PubMed

    Hayakawa, Tetsu; Takanaga, Akinori; Tanaka, Koichi; Maeda, Seishi; Seki, Makoto

    2002-06-01

    The accessory nucleus is composed of neurons in the medial column that innervate the sternocleidomastoid muscle, and neurons in the lateral column that innervate the trapezius muscle. We retrogradely labeled these neurons by injection of cholera toxin conjugated horseradish peroxidase into the sternomastoid (SM) or the clavotrapezius (CT) muscles, and investigated fine structure and synaptology of these neurons. Almost all SM and CT motoneurons had the appearance of alpha-motoneurons, i.e., large, oval or polygonal cells containing well-developed organelles, Nissl bodies, and a prominent spherical nucleus. More than 60% of the somatic membrane was covered with terminals. The SM motoneurons (34.4 x 52.2 microm, 1,363.1 microm(2) in a section) were slightly larger than the CT motoneurons (32.8 x 54.2 microm, 1,180.8 microm(2)). The average number of axosomatic terminals in a section was 52.2 for the SM, and 54.2 for the CT motoneurons. More than half of them (58.0%) contained pleomorphic vesicles and made symmetric synaptic contacts (Gray's type II) with the SM motoneurons, while 57.9% of them contained round vesicles and made asymmetric synaptic contacts (Gray's type I) with the CT motoneurons. A few C-terminals were present on the SM (3.5) and the CT (3.7) motoneurons. About 60% of the axodendritic terminals were Gray's type I in both the SM and the CT motoneurons. A few labeled small motoneurons were also found among the SM and the CT motoneurons. They were small (19.2 x 26.2 microm, 367.0 microm(2)), round cells containing poorly developed organelles with a few axosomatic terminals (9.3). Only 20% of the somatic membrane was covered with the terminals. Thus, these neurons were presumed to be gamma-motoneurons. These results indicate that the motoneurons in the medial and the lateral column of the accessory nucleus have different ultrastructural characteristics.

  11. An assessment of the intra- and inter-reliability of the lumbar paraspinal muscle parameters using CT scan and magnetic resonance imaging.

    PubMed

    Hu, Zhi-Jun; He, Jian; Zhao, Feng-Dong; Fang, Xiang-Qian; Zhou, Li-Na; Fan, Shun-Wu

    2011-06-01

    A reliability study was conducted. To estimate the intra- and intermeasurement errors in the measurements of functional cross-sectional area (FCSA), density, and T2 signal intensity of paraspinal muscles using computed tomography (CT) scan and magnetic resonance imaging (MRI). CT scan and MRI had been used widely to measure the cross-sectional area and degeneration of the back muscles in spine and muscle research. But there is still no systemic study to analyze the reliability of these measurements. This study measured the FCSA and fatty infiltration (density on CT scan and T2 signal intensity on MRI) of the paraspinal muscles at L3-L4, L4-L5, and L5-S1 in 29 patients with chronic low back pain. Two experienced musculoskeletal radiologists and one superior spine surgeon traced the region of interest twice within 3 weeks for measurement of the intra- and interobserver reliability. The intraclass correlation coefficients (ICCs) of the intra-reliability ranged from fair to excellent for FCSA, and good to excellent for fatty infiltration. The ICCs of the inter-reliability ranged from fair to excellent for FCSA, and good to excellent for fatty infiltration. There were no significant differences between CT scan and MRI in reliability results, except in the relative standard error of fatty infiltration measurement. The ICCs of the FCSA measurement between CT scan and MRI ranged from poor to good. The reliabilities of the CT scan and MRI for measuring the FCSA and fatty infiltration of the atrophied lumbar paraspinal muscles were acceptable. It was reliable for using uniform one image method for a single paraspinal muscle evaluation study. And the authors preferred to advise the MRI other than CT scan for paraspinal muscles measurements of FCSA and fatty infiltration.

  12. MO-F-CAMPUS-J-04: One-Year Analysis of Elekta CBCT Image Quality Using NPS and MTF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakahara, S; Tachibana, M; Watanabe, Y

    2015-06-15

    Purpose: To compare quantitative image quality (IQ) evaluation methods using Noise Power Spectrum (NPS) and Modulation Transfer Function (MTF) with standard IQ analyses for minimizing the observer subjectivity of the standard methods and maximizing the information content. Methods: For our routine IQ tests of Elekta XVI Cone-Beam CT, image noise was quantified by the standard deviation of CT number (CT#) (Sigma) over a small area in an IQ test phantom (CatPhan), and the high spatial resolution (HSR) was evaluated by the number of line-pairs (LP#) visually recognizable on the image. We also measured the image uniformity, the low contrast resolutionmore » ratio, and the distances of two points for geometrical accuracy. For this study, we did additional evaluation of the XVI data for 12 monthly IQ tests by using NPS for noise, MTF for HSR, and the CT#-to-density relationship. NPS was obtained by applying Fourier analysis in a small area on the uniformity test section of CatPhan. The MTF analysis was performed by applying the Droege-Morin (D-M) method to the line pairs on the phantom. The CT#-to-density was obtained for inserts in the low-contrast test section of the phantom. Results: All the quantities showed a noticeable change over the one-year period. Especially the noise level changed significantly after a repair of the imager. NPS was more sensitive to the IQ change than Sigma. MTF could provide more quantitative and objective evaluation of the HSR. The CT# was very different from the expected CT#; but, the CT#-to-density curves were constant within 5% except two months. Conclusion: Since the D-M method is easy to implement, we recommend using MTF instead of the LP# even for routine periodic QA. The month-to-month variation of IQ was not negligible; hence a routine IQ test must be performed, particularly after any modification of hardware including detector calibration.« less

  13. Comparison of standard radiography and computed tomography in 21 dogs with maxillary masses.

    PubMed

    Ghirelli, Carolina O; Villamizar, Lenin A; Pinto, Ana Carolina B C Fonseca

    2013-01-01

    Imaging of patients with oral cancer is required to determine tumor extension in order to assist in prognosis and surgical planning. Conventional screen-film radiography (SFR) used to be the most common method for oral assessment, but computed tomography (CT) has become more available and is being used for obtaining complementary information. CT examinations eliminate superimposition by acquiring cross-sectional images of the region of interest. The objective of this study was to determine the diagnostic value of SFR compared with CT examinations for evaluation of oral masses in dogs. Twenty-one dogs received head and thorax SFR, and pre- and post-contrast head CT. Bony changes were observed in 80.9% and 95.2% of the cases in SFR and CT studies, respectively. Invasion of adjacent structures (i.e. nasal cavity, frontal and sphenoidal sinuses, orbit, maxillary recess, nasopharynx) was observed in only 30% of cases with SFR while CT showed 90.4% involvement. CT is an important preoperative examination modality and is more effective in identifying bone changes and tumor invasion of adjacent structures compared with SFR.

  14. Hot Flashes and Carotid Intima Media Thickness among Midlife Women

    PubMed Central

    Thurston, Rebecca C.; Sutton-Tyrrell, Kim; Everson-Rose, Susan A.; Hess, Rachel; Powell, Lynda H.; Matthews, Karen A.

    2010-01-01

    Objective Emerging evidence suggests associations between menopausal hot flashes and cardiovascular risk. Whether hot flashes are associated with intima media thickness (IMT) or IMT changes over time is unknown. We hypothesized that reported hot flashes would be associated with greater IMT cross-sectionally and with greater IMT progression over two years. Methods Participants were 432 women ages 45-58 at baseline participating in SWAN Heart, an ancillary study to the Study of Women's Health Across the Nation. Measures at the SWAN Heart baseline and follow-up visit two years later included a carotid artery ultrasound, reported hot flashes (past two weeks: none, 1-5, ≥6 days), and a blood sample for measurement of estradiol. Results Women reporting hot flashes ≥6 days in the prior two weeks had significantly higher IMT than women without hot flashes at baseline (mean difference(SE), mm =0.02(0.01), p=0.03) and follow-up (mean difference(SE), mm =0.02(0.01), p=0.04) visits, controlling for demographic factors and cardiovascular risk factors. Reporting hot flashes at both study visits was associated with higher follow-up IMT relative to reporting hot flashes at neither visit (mean difference(SE), mm=0.03(0.01), p=0.03). Associations between hot flashes and IMT largely remained after adjusting for estradiol. An interaction between hot flashes and obesity status was observed (p=0.05) such that relations between hot flashes and IMT were observed principally among overweight/obese women. Hot flashes were not associated with IMT progression. Conclusions These findings provided some indication that women reporting hot flashes ≥6 days in the prior two weeks may have higher IMT than women without hot flashes, particularly for women who are overweight or obese. Further work should determine whether hot flashes mark adverse underlying vascular changes. PMID:21242820

  15. Benefit of computer-aided detection analysis for the detection of subsolid and solid lung nodules on thin- and thick-section CT.

    PubMed

    Godoy, Myrna C B; Kim, Tae Jung; White, Charles S; Bogoni, Luca; de Groot, Patricia; Florin, Charles; Obuchowski, Nancy; Babb, James S; Salganicoff, Marcos; Naidich, David P; Anand, Vikram; Park, Sangmin; Vlahos, Ioannis; Ko, Jane P

    2013-01-01

    The objective of our study was to evaluate the impact of computer-aided detection (CAD) on the identification of subsolid and solid lung nodules on thin- and thick-section CT. For 46 chest CT examinations with ground-glass opacity (GGO) nodules, CAD marks computed using thin data were evaluated in two phases. First, four chest radiologists reviewed thin sections (reader(thin)) for nodules and subsequently CAD marks (reader(thin) + CAD(thin)). After 4 months, the same cases were reviewed on thick sections (reader(thick)) and subsequently with CAD marks (reader(thick) + CAD(thick)). Sensitivities were evaluated. Additionally, reader(thick) sensitivity with assessment of CAD marks on thin sections was estimated (reader(thick) + CAD(thin)). For 155 nodules (mean, 5.5 mm; range, 4.0-27.5 mm)-74 solid nodules, 22 part-solid (part-solid nodules), and 59 GGO nodules-CAD stand-alone sensitivity was 80%, 95%, and 71%, respectively, with three false-positives on average (0-12) per CT study. Reader(thin) + CAD(thin) sensitivities were higher than reader(thin) for solid nodules (82% vs 57%, p < 0.001), part-solid nodules (97% vs 81%, p = 0.0027), and GGO nodules (82% vs 69%, p < 0.001) for all readers (p < 0.001). Respective sensitivities for reader(thick), reader(thick) + CAD(thick), reader(thick) + CAD(thin) were 40%, 58% (p < 0.001), and 77% (p < 0.001) for solid nodules; 72%, 73% (p = 0.322), and 94% (p < 0.001) for part-solid nodules; and 53%, 58% (p = 0.008), and 79% (p < 0.001) for GGO nodules. For reader(thin), false-positives increased from 0.64 per case to 0.90 with CAD(thin) (p < 0.001) but not for reader(thick); false-positive rates were 1.17, 1.19, and 1.26 per case for reader(thick), reader(thick) + CAD(thick), and reader(thick) + CAD(thin), respectively. Detection of GGO nodules and solid nodules is significantly improved with CAD. When interpretation is performed on thick sections, the benefit is greater when CAD marks are reviewed on thin rather than thick sections.

  16. Activity concentration measurements using a conjugate gradient (Siemens xSPECT) reconstruction algorithm in SPECT/CT.

    PubMed

    Armstrong, Ian S; Hoffmann, Sandra A

    2016-11-01

    The interest in quantitative single photon emission computer tomography (SPECT) shows potential in a number of clinical applications and now several vendors are providing software and hardware solutions to allow 'SUV-SPECT' to mirror metrics used in PET imaging. This brief technical report assesses the accuracy of activity concentration measurements using a new algorithm 'xSPECT' from Siemens Healthcare. SPECT/CT data were acquired from a uniform cylinder with 5, 10, 15 and 20 s/projection and NEMA image quality phantom with 25 s/projection. The NEMA phantom had hot spheres filled with an 8 : 1 activity concentration relative to the background compartment. Reconstructions were performed using parameters defined by manufacturer presets available with the algorithm. The accuracy of activity concentration measurements was assessed. A dose calibrator-camera cross-calibration factor (CCF) was derived from the uniform phantom data. In uniform phantom images, a positive bias was observed, ranging from ∼6% in the lower count images to ∼4% in the higher-count images. On the basis of the higher-count data, a CCF of 0.96 was derived. As expected, considerable negative bias was measured in the NEMA spheres using region mean values whereas positive bias was measured in the four largest NEMA spheres. Nonmonotonically increasing recovery curves for the hot spheres suggested the presence of Gibbs edge enhancement from resolution modelling. Sufficiently accurate activity concentration measurements can easily be measured on images reconstructed with the xSPECT algorithm without a CCF. However, the use of a CCF is likely to improve accuracy further. A manual conversion of voxel values into SUV should be possible, provided that the patient weight, injected activity and time between injection and imaging are all known accurately.

  17. Intraoperative cone-beam computed tomography and multi-slice computed tomography in temporal bone imaging for surgical treatment.

    PubMed

    Erovic, Boban M; Chan, Harley H L; Daly, Michael J; Pothier, David D; Yu, Eugene; Coulson, Chris; Lai, Philip; Irish, Jonathan C

    2014-01-01

    Conventional computed tomography (CT) imaging is the standard imaging technique for temporal bone diseases, whereas cone-beam CT (CBCT) imaging is a very fast imaging tool with a significant less radiation dose compared with conventional CT. We hypothesize that a system for intraoperative cone-beam CT provides comparable image quality to diagnostic CT for identifying temporal bone anatomical landmarks in cadaveric specimens. Cross-sectional study. University tertiary care facility. Twenty cadaveric temporal bones were affixed into a head phantom and scanned with both a prototype cone-beam CT C-arm and multislice helical CT. Imaging performance was evaluated by 3 otologic surgeons and 1 head and neck radiologist. Participants were presented images in a randomized order and completed landmark identification questionnaires covering 21 structures. CBCT and multislice CT have comparable performance in identifying temporal structures. Three otologic surgeons indicated that CBCT provided statistically equivalent performance for 19 of 21 landmarks, with CBCT superior to CT for the chorda tympani and inferior for the crura of the stapes. Subgroup analysis showed that CBCT performed superiorly for temporal bone structures compared with CT. The radiologist rated CBCT and CT as statistically equivalent for 18 of 21 landmarks, with CT superior to CBCT for the crura of stapes, chorda tympani, and sigmoid sinus. CBCT provides comparable image quality to conventional CT for temporal bone anatomical sites in cadaveric specimens. Clinical applications of low-dose CBCT imaging in surgical planning, intraoperative guidance, and postoperative assessment are promising but require further investigation.

  18. Multidetector CT of musculoskeletal disease in the pediatric patient: principles, techniques, and clinical applications.

    PubMed

    Fayad, Laura M; Johnson, Pamela; Fishman, Elliot K

    2005-01-01

    Computed tomography (CT) plays an important role in the evaluation of musculoskeletal disease in the pediatric patient. With the advent of high-performance 16-section multidetector CT, images can be produced with subsecond gantry rotation times and with submillimeter acquisition, which yields true isotropic high-resolution volume data sets; these features are not attainable with older spiral CT technology. Such capabilities are particularly helpful in the evaluation of pediatric patients by virtually eliminating the need for sedation and minimizing dependence on patient cooperation. The role of three-dimensional (3D) volume imaging in the evaluation of pediatric musculoskeletal disease continues to evolve, with this technique becoming increasingly important in detection and characterization of lesions as well as in decisions about patient care. Specific designs and protocols for multidetector CT studies can be selected to minimize radiation dose to the patient. Principal clinical applications of 3D CT in evaluation of the pediatric musculoskeletal system include developmental abnormalities, trauma, neoplasms, and postoperative imaging.

  19. Hot-atom versus Eley-Rideal dynamics in hydrogen recombination on Ni(100). I. The single-adsorbate case.

    PubMed

    Martinazzo, R; Assoni, S; Marinoni, G; Tantardini, G F

    2004-05-08

    We compare the efficiency of the Eley-Rideal (ER) reaction with the formation of hot-atom (HA) species in the simplest case, i.e., the scattering of a projectile off a single adsorbate, considering the Hydrogen and Hydrogen-on-Ni(100) system. We use classical mechanics and the accurate embedded diatomics-in-molecules potential to study the collision system over a wide range of collision energies (0.10-1.50 eV), both with a rigid and a nonrigid Ni substrate and for impact on the occupied and neighboring empty cells. In the rigid model metastable and truly bound hot-atoms occur and we find that the cross section for the formation of bound hot-atoms is considerably higher than that for the ER reaction over the whole range of collision energies examined. Metastable hot-atoms form because of the inefficient energy transfer to the adsorbate and have lifetimes of the order 0.1-0.7 ps, depending on the collision energy. When considering the effects of lattice vibrations we find, on average, a consistent energy transfer to the substrate, say 0.1-0.2 eV, which forced us to devise a two-step dynamical model to get rid of the problems associated with the use of periodic boundary conditions. Results for long-lived HA formation due to scattering on the occupied cell at a surface temperature of 120 K agree well with those of the rigid model, suggesting that in the above process the substrate plays only a secondary role and further calculations at surface temperatures of 50 and 300 K are in line with these findings. However, considerably high cross sections for formation of long-lived hot-atoms result also from scattering off the neighboring cells where the energy transfer to the lattice cannot be neglected. Metastable hot-atoms are reduced in number and have usually lifetimes shorter than those of the rigid-model, say less than 0.3 ps. In addition, ER cross sections are only slightly affected by the lattice motion and show a little temperature dependence. Finally, we find also that absorption and reflection strongly depend on the correct consideration of lattice vibrations and the occurrence of trapping. (c) 2004 American Institute of Physics.

  20. On 3-D inelastic analysis methods for hot section components (base program)

    NASA Technical Reports Server (NTRS)

    Wilson, R. B.; Bak, M. J.; Nakazawa, S.; Banerjee, P. K.

    1986-01-01

    A 3-D Inelastic Analysis Method program is described. This program consists of a series of new computer codes embodying a progression of mathematical models (mechanics of materials, special finite element, boundary element) for streamlined analysis of: (1) combustor liners, (2) turbine blades, and (3) turbine vanes. These models address the effects of high temperatures and thermal/mechanical loadings on the local (stress/strain)and global (dynamics, buckling) structural behavior of the three selected components. Three computer codes, referred to as MOMM (Mechanics of Materials Model), MHOST (Marc-Hot Section Technology), and BEST (Boundary Element Stress Technology), have been developed and are briefly described in this report.

  1. 3D inelastic analysis methods for hot section components

    NASA Technical Reports Server (NTRS)

    Dame, L. T.; Chen, P. C.; Hartle, M. S.; Huang, H. T.

    1985-01-01

    The objective is to develop analytical tools capable of economically evaluating the cyclic time dependent plasticity which occurs in hot section engine components in areas of strain concentration resulting from the combination of both mechanical and thermal stresses. Three models were developed. A simple model performs time dependent inelastic analysis using the power law creep equation. The second model is the classical model of Professors Walter Haisler and David Allen of Texas A and M University. The third model is the unified model of Bodner, Partom, et al. All models were customized for linear variation of loads and temperatures with all material properties and constitutive models being temperature dependent.

  2. Creep fatigue life prediction for engine hot section materials (isotropic): Fourth year progress review

    NASA Technical Reports Server (NTRS)

    Nelson, Richard S.; Schoendorf, John F.

    1986-01-01

    As gas turbine technology continues to advance, the need for advanced life prediction methods for hot section components is becoming more and more evident. The complex local strain and temperature histories at critical locations must be accurately interpreted to account for the effects of various damage mechanisms (such as fatigue, creep, and oxidation) and their possible interactions. As part of the overall NASA HOST effort, this program is designed to investigate these fundamental damage processes, identify modeling strategies, and develop practical models which can be used to guide the early design and development of new engines and to increase the durability of existing engines.

  3. Hot-Film and Hot-Wire Anemometry for a Boundary Layer Active Flow Control Test

    NASA Technical Reports Server (NTRS)

    Lenahan, Keven C.; Schatzman, David M.; Wilson, Jacob Samuel

    2013-01-01

    Unsteady active flow control (AFC) has been used experimentally for many years to minimize bluff-body drag. This technology could significantly improve performance of rotorcraft by cleaning up flow separation. It is important, then, that new actuator technologies be studied for application to future vehicles. A boundary layer wind tunnel was constructed with a 1ft-x-3ft test section and unsteady measurement instrumentation to study how AFC manipulates the boundary layer to overcome adverse pressure gradients and flow separation. This unsteady flow control research requires unsteady measurement methods. In order to measure the boundary layer characteristics, both hot-wire and hot-film Constant Temperature Anemometry is used. A hot-wire probe is mounted in the flow to measure velocity while a hot-film array lays on the test surface to measure skin friction. Hot-film sensors are connected to an anemometer, a Wheatstone bridge circuit with an output that corresponds to the dynamic flow response. From this output, the time varying flow field, turbulence, and flow reversal can be characterized. Tuning the anemometers requires a fan test on the hot-film sensors to adjust each output. This is a delicate process as several variables drastically affect the data, including control resistance, signal input, trim, and gain settings.

  4. Reconstruction of the 3-D Shape and Crystal Preferred Orientation of Olivine: A Combined X-ray µ-CT and EBSD-SEM approach

    NASA Astrophysics Data System (ADS)

    Kahl, Wolf-Achim; Hidas, Károly; Dilissen, Nicole; Garrido, Carlos J.; López-Sánchez Vizcaíno, Vicente; Jesús Román-Alpiste, Manuel

    2017-04-01

    The complete reconstruction of the microstructure of rocks requires, among others, a full description of the shape preferred orientation (SPO) and crystal preferred orientation (CPO) of the constituent mineral phases. New advances in instrumental analyses, particularly electron backscatter diffraction (EBSD) coupled to focused ion beam-scanning electron microscope (FIB-SEM), allows a complete characterization of SPO and CPO in rocks at the micron scale [1-2]. Unfortunately, the large grain size of many crystalline rocks, such as peridotite, prevents a representative characterization of the CPO and SPO of their constituent minerals by this technique. Here, we present a new approach combining X-ray micro computed tomography (µ-CT) and EBSD to reconstruct the geographically oriented, 3-D SPO and CPO of cm- to mm-sized olivine crystals in two contrasting fabric types of chlorite harzburgites (Almírez ultramafic massif, SE Spain). The semi-destructive sample treatment involves drilling of geographically oriented micro drills in the field and preparation of oriented thin sections from µ-CT scanned cores. This allows for establishing the link among geological structures, macrostructure, fabric, and 3-D SPO-CPO at the thin section scale. Based on EBSD analyses, different CPO groups of olivine crystals can be discriminated in the thin sections and allocated to 3-D SPO in the µ-CT volume data. This approach overcomes the limitations of both methods (i.e., no crystal orientation data in µ-CT and no spatial information in EBSD), hence 3-D orientation of the crystallographic axes of olivines from different orientation groups could be correlated with the crystal shapes of olivine grains. This combined µ-CT and EBSD technique enables the correlation of both SPO and CPO and representative grain size, and is capable to characterize the 3-D microstructure of olivine-bearing rocks at the hand specimen scale. REFERENCES 1. Zaefferer, S., Wright, S.I., Raabe, D., 2008. Three-Dimensional orientation microscopy in a focused ion beam-scanning electron microscope: A new dimension of microstructure characterization. Metallurgical and Materials Transactions A 39, 374-389. 2. Burnett, T.L., Kelley, R., Winiarski, B., Contreras, L., Daly, M., Gholinia, A., Burke, M.G., Withers, P.J., 2016. Large volume serial section tomography by Xe Plasma FIB dual beam microscopy. Ultramicroscopy 161, 119-129.

  5. Computer aided stress analysis of long bones utilizing computer tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marom, S.A.

    1986-01-01

    A computer aided analysis method, utilizing computed tomography (CT) has been developed, which together with a finite element program determines the stress-displacement pattern in a long bone section. The CT data file provides the geometry, the density and the material properties for the generated finite element model. A three-dimensional finite element model of a tibial shaft is automatically generated from the CT file by a pre-processing procedure for a finite element program. The developed pre-processor includes an edge detection algorithm which determines the boundaries of the reconstructed cross-sectional images of the scanned bone. A mesh generation procedure than automatically generatesmore » a three-dimensional mesh of a user-selected refinement. The elastic properties needed for the stress analysis are individually determined for each model element using the radiographic density (CT number) of each pixel with the elemental borders. The elastic modulus is determined from the CT radiographic density by using an empirical relationship from the literature. The generated finite element model, together with applied loads, determined from existing gait analysis and initial displacements, comprise a formatted input for the SAP IV finite element program. The output of this program, stresses and displacements at the model elements and nodes, are sorted and displayed by a developed post-processor to provide maximum and minimum values at selected locations in the model.« less

  6. Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goodsitt, Mitchell M.; Christodoulou, Emmanuel G.; Larson, Sandra C.

    2011-04-15

    Purpose: This study was performed to investigate the accuracies of the synthesized monochromatic images and effective atomic number maps obtained with the new GE Discovery CT750 HD CT scanner. Methods: A Gammex-RMI model 467 tissue characterization phantom and the CT number linearity section of a Phantom Laboratory Catphan 600 phantom were scanned using the dual energy (DE) feature on the GE CT750 HD scanner. Synthesized monochromatic images at various energies between 40 and 120 keV and effective atomic number (Z{sub eff}) maps were generated. Regions of interest were placed within these images/maps to measure the average monochromatic CT numbers andmore » average Z{sub eff} of the materials within these phantoms. The true Z{sub eff} values were either supplied by the phantom manufacturer or computed using Mayneord's equation. The linear attenuation coefficients for the true CT numbers were computed using the NIST XCOM program with the input of manufacturer supplied elemental compositions and densities. The effects of small variations in the assumed true densities of the materials were also investigated. Finally, the effect of body size on the accuracies of the synthesized monochromatic CT numbers was investigated using a custom lumbar section phantom with and without an external fat-mimicking ring. Results: Other than the Z{sub eff} of the simulated lung inserts in the tissue characterization phantom, which could not be measured by DECT, the Z{sub eff} values of all of the other materials in the tissue characterization and Catphan phantoms were accurate to 15%. The accuracies of the synthesized monochromatic CT numbers of the materials in both phantoms varied with energy and material. For the 40-120 keV range, RMS errors between the measured and true CT numbers in the Catphan are 8-25 HU when the true CT numbers were computed using the nominal plastic densities. These RMS errors improve to 3-12 HU for assumed true densities within the nominal density {+-}0.02 g/cc range. The RMS errors between the measured and true CT numbers of the tissue mimicking materials in the tissue characterization phantom over the 40-120 keV range varied from about 6 HU-248 HU and did not improve as dramatically with small changes in assumed true density. Conclusions: Initial tests indicate that the Z{sub eff} values computed with DECT on this scanner are reasonably accurate; however, the synthesized monochromatic CT numbers can be very inaccurate, especially for dense tissue mimicking materials at low energies. Furthermore, the synthesized monochromatic CT numbers of materials still depend on the amount of the surrounding tissues especially at low keV, demonstrating that the numbers are not truly monochromatic. Further research is needed to develop DE methods that produce more accurate synthesized monochromatic CT numbers.« less

  7. Thin-section computed tomography findings in 104 immunocompetent patients with adenovirus pneumonia.

    PubMed

    Park, Chan Kue; Kwon, Hoon; Park, Ji Young

    2017-08-01

    Background To date, there has been no computed tomography (CT) evaluation of adenovirus pneumonia in a large number of immunocompetent patients. Purpose To describe the thin-section CT findings of immunocompetent patients with adenovirus pneumonia. Material and Methods We prospectively enrolled 104 patients with adenovirus pneumonia from a military hospital. CT scans of each patient were retrospectively and independently assessed by two radiologists for the presence of abnormalities, laterality and zonal predominance of the parenchymal abnormalities, and dominant imaging patterns and their anatomic distributions. Results CT findings included consolidation (n = 92), ground-glass opacity (GGO; n = 82), septal thickening (n = 34), nodules (n = 46), bronchial wall thickening (n = 32), pleural effusion (n = 16), and lymphadenopathy (n = 3). Eighty-four patients (81%) exhibited unilateral parenchymal abnormalities and 57 (57%) exhibited lower lung zone abnormalities. The most frequently dominant CT pattern was consolidation with surrounding GGO (n = 50), with subpleural (70%) and peribronchovascular (94%) distributions. Consolidation-the second-most common pattern (n = 33)-also exhibited subpleural (79%) and peribronchovascular (97%) distributions. The dominant nodule pattern (n = 14) exhibited mixed (64%) and peribronchovascular (100%) distributions. A dominant GGO pattern was only observed in four patients; none had central distribution. Conclusion Although the manifestations of adenovirus pneumonia on CT are varied, we found the most frequent pattern was consolidation with or without surrounding GGO, with subpleural and peribronchovascular distributions. Parenchymal abnormalities were predominantly unilateral and located in the lower lung zone. If dominant consolidation findings are present in immunocompetent patients during the early stages, adenovirus pneumonia should be considered.

  8. Risk factors for hot flashes among women undergoing the menopausal transition: baseline results from the Midlife Women's Health Study

    PubMed Central

    Gallicchio, Lisa; Miller, Susan R.; Kiefer, Judith; Greene, Teresa; Zacur, Howard A.; Flaws, Jodi A.

    2015-01-01

    Objective The aim of this study was to examine the associations between demographic characteristics, health behaviors, hormone concentrations, and the experiencing of any, current, more severe, and more frequent midlife hot flashes. Methods Baseline data were analyzed from 732 women aged 45 to 54 years enrolled in the Midlife Women's Health Study. A clinic visit was conducted to collect blood samples for hormone assays and to measure ovarian volume using transvaginal ultrasound. A self-administered questionnaire ascertained information on demographic factors, health habits, and hot flashes history. Multivariable logistic regression was conducted to examine the associations between potential risk factors and the hot flashes outcomes. Results Approximately 45% of participants reported experiencing midlife hot flashes. In the covariate-adjusted models, older age, peri-menopausal status, current and former cigarette smoking, and depressive symptoms were significantly associated with increased odds of all of the hot flashes outcomes. In addition, history of oral contraceptive use was associated with increased odds of any hot flashes. In contrast, higher current alcohol intake was significantly associated with decreased odds of any, current, and more severe hot flashes. Higher estradiol and progesterone concentrations were significantly associated with decreased odds of all hot flashes outcomes. Conclusions Although the temporalities of such associations are not known due to the cross-sectional nature of the data, these observed relationships can help to identify women at risk for hot flashes. PMID:25783472

  9. Serum leptin levels, hormone levels, and hot flashes in midlife women.

    PubMed

    Alexander, Carolyn; Cochran, Chrissy J; Gallicchio, Lisa; Miller, Susan R; Flaws, Jodi A; Zacur, Howard

    2010-08-01

    To examine the associations between serum leptin levels, sex steroid hormone levels, and hot flashes in normal weight and obese midlife women. Cross-sectional study. University clinic. 201 Caucasian, nonsmoking women aged 45 to 54 years with a body mass index of <25 kg/m2 or >or=30 kg/m2. Questionnaire, fasting blood samples. Serum leptin and sex steroid hormone levels. Correlation and regression models were performed to examine associations between leptin levels, hormone levels, and hot flashes. Leptin levels were associated with BMI, with "ever experiencing hot flashes" (questionnaire), with hot flashes within the last 30 days, and with duration of hot flashes (>1 year, P=.03). Leptin was positively correlated with testosterone, free testosterone index, and free estrogen index and inversely associated with levels of sex hormone-binding globulin. In women with a body mass index>or=30 kg/m2, leptin levels no longer correlated with testosterone levels. Serum leptin levels are associated with the occurrence and duration of hot flashes in midlife women; however, no correlation was found between leptin and serum estradiol. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  10. Characteristics of internalizing and externalizing disorders in medication-naive, clinically referred children with attention deficit hyperactivity disorder, combined type and dysthymic disorder.

    PubMed

    Sanders, Michelle; Arduca, Yolanda; Karamitsios, Mary; Boots, Marilyn; Vance, Alasdair

    2005-05-01

    Internalizing and externalizing disorders are frequently comorbid with attention deficit hyperactivity disorder, combined type (ADHD-CT) and dysthymic disorder (DD) in referred primary school-age children, yet there has been relatively little systematic research of the nature of these comorbid disorders. We describe the characteristics of parent- and child-reported internalizing and externalizing disorders in primary school-age children with ADHD-CT and DD. A cross-sectional study of 45 clinically referred medication naive children with ADHD-CT and DD, examining parent and child reports of internalizing and externalizing disorders, defined categorically and dimensionally. Generalized anxiety disorder and separation anxiety disorder were increased in the DD groups, whether ADHD-CT was present or not. Major depressive disorder was increased in the ADHD-CT and DD group compared to the ADHD-CT alone and the DD alone groups. Conduct disorder was increased in the ADHD-CT alone group compared to the DD with and without ADHD-CT groups. Verbal and fullscale IQ were increased in the DD groups, whether ADHD-CT was present or not, compared to the ADHD-CT alone group. There is emerging evidence that DD and anxiety may represent a different phenotypic expression of a common underlying aetiological process, while the co-occurrence of ADHD-CT and anxiety disorders remains unclear. Only the ADHD-CT and DD group is significantly associated with major depressive disorder, which suggests an additive effect. In contrast, conduct disorder and decreased verbal and fullscale IQ are only associated with the ADHD-CT group, which may suggest a protective effect of DD when comorbid with ADHD-CT. From a research perspective, it is important to confirm these found associations in larger samples derived from epidemiological populations.

  11. Correlations between symptoms, nasal endoscopy, and in-office computed tomography in post-surgical chronic rhinosinusitis patients.

    PubMed

    Ryan, William R; Ramachandra, Tara; Hwang, Peter H

    2011-03-01

    To determine correlations between symptoms, nasal endoscopy findings, and computed tomography (CT) scan findings in post-surgical chronic rhinosinusitis (CRS) patients. Cross-sectional. A total of 51 CRS patients who had undergone endoscopic sinus surgery (ESS) completed symptom questionnaires, underwent endoscopy, and received an in-office sinus CT scan during one clinic visit. For metrics, we used the Sinonasal Outcomes Test-20 (SNOT-20) questionnaire, visual analog symptom scale (VAS), Lund-Kennedy endoscopy scoring scale, and Lund-MacKay (LM) CT scoring scale. We determined Pearson correlation coefficients, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) between scores for symptoms, endoscopy, and CT. The SNOT-20 score and most VAS symptoms had poor correlation coefficients with both endoscopy and CT scores (0.03-0.24). Nasal drainage of pus, nasal congestion, and impaired sense of smell had moderate correlation coefficients with endoscopy and CT (0.24-0.42). Endoscopy had a strong correlation coefficient with CT (0.76). Drainage, edema, and polyps had strong correlation coefficients with CT (0.80, 0.69, and 0.49, respectively). Endoscopy had a PPV of 92.5% and NPV of 45.5% for detecting an abnormal sinus CT (LM score ≥1). In post-ESS CRS patients, most symptoms do not correlate well with either endoscopy or CT findings. Endoscopy and CT scores correlate well. Abnormal endoscopy findings have the ability to confidently rule in the presence of CT opacification, thus validating the importance of endoscopy in clinical decision making. However, a normal endoscopy cannot assure a normal CT. Thus, symptoms, endoscopy, and CT are complementary in the evaluation of the post-ESS CRS patient. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc., Rhinological, and Otological Society, Inc.

  12. Clinical, pathological and thin-section CT features of persistent multiple ground-glass opacity nodules: comparison with solitary ground-glass opacity nodule.

    PubMed

    Kim, Tae Jung; Goo, Jin Mo; Lee, Kyung Won; Park, Chang Min; Lee, Hyun Ju

    2009-05-01

    To retrospectively compare the clinical, pathological, and thin-section CT features of persistent multiple ground-glass opacity (GGO) nodules with those of solitary GGO nodules. Histopathologic specimens were obtained from 193 GGO nodules in 136 patients (87 women, 49 men; mean age, 57; age range 33-81). The clinical data, pathologic findings, and thin-section CT features of multiple and solitary GGO nodules were compared by using t-test or Fisher's exact test. Multiple GGO nodules (n=105) included atypical adenomatous hyperplasia (AAH) (n=31), bronchioloalveolar carcinoma (BAC) (n=33), adenocarcinoma (n=34) and focal interstitial fibrosis (n=7). Solitary GGO nodules included AAH (n=8), BAC (n=15), adenocarcinoma (n=55) and focal interstitial fibrosis (n=10). AAH (P=.001) and BAC (P=.029) were more frequent in multiple GGO nodules, whereas adenocarcinoma (P<.001) was more frequent in solitary GGO nodules. Female sex (P<.001), nonsmoker (P=.012) and multiple primary lung cancers (P<.001) were more frequent for multiple GGO nodules, which were smaller (12 mm+/-7.9) than solitary GGO nodules (17 mm+/-8.1) (P<.001). Air-bronchogram (P=.019), bubble-lucency (P=.004), and pleural retraction (P<.001) were more frequent in solitary GGO nodules. There was no postoperative recurrence except for one patient with multiple GGO nodules and one with solitary GGO nodule. Clinical, pathological, and thin-section CT features of persistent multiple GGO nodules were found to differ from those of solitary GGO nodules. Nevertheless, the two nodule types can probably be followed up and managed in a similar manner because their prognoses were found to be similar.

  13. Characterization of compact-toroid injection during formation, translation, and field penetration

    NASA Astrophysics Data System (ADS)

    Matsumoto, T.; Roche, T.; Allfrey, I.; Sekiguchi, J.; Asai, T.; Gota, H.; Cordero, M.; Garate, E.; Kinley, J.; Valentine, T.; Waggoner, W.; Binderbauer, M.; Tajima, T.

    2016-11-01

    We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ˜1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.

  14. Characterization of compact-toroid injection during formation, translation, and field penetration.

    PubMed

    Matsumoto, T; Roche, T; Allfrey, I; Sekiguchi, J; Asai, T; Gota, H; Cordero, M; Garate, E; Kinley, J; Valentine, T; Waggoner, W; Binderbauer, M; Tajima, T

    2016-11-01

    We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.

  15. The D1CT-7 mouse model of Tourette syndrome displays sensorimotor gating deficits in response to spatial confinement.

    PubMed

    Godar, Sean C; Mosher, Laura J; Strathman, Hunter J; Gochi, Andrea M; Jones, Cori M; Fowler, Stephen C; Bortolato, Marco

    2016-07-01

    The D1CT-7 mouse is one of the best known animal models of Tourette syndrome (TS), featuring spontaneous tic-like behaviours sensitive to standard TS therapies; these characteristics ensure a high face and predictive validity of this model, yet its construct validity remains elusive. To address this issue, we studied the responses of D1CT-7 mice to two critical components of TS pathophysiology: the exacerbation of tic-like behaviours in response to stress and the presence of sensorimotor gating deficits, which are thought to reflect the perceptual alterations causing the tics. D1CT-7 and wild-type (WT) littermates were subjected to a 20 min session of spatial confinement (SC) within an inescapable, 10 cm wide cylindrical enclosure. Changes in plasma corticosterone levels, tic-like behaviours and other spontaneous responses were measured. SC-exposed mice were also tested for the prepulse inhibition (PPI) of the startle response (a sensorimotor gating index) and other TS-related behaviours, including open-field locomotion, novel object exploration and social interaction and compared with non-confined counterparts. SC produced a marked increase in corticosterone concentrations in both D1CT-7 and WT mice. In D1CT-7, but not WT mice, SC exacerbated tic-like and digging behaviours, and triggered PPI deficits and aggressive responses. Conversely, SC did not modify locomotor activity or novel object exploration in D1CT-7 mice. Both tic-like behaviours and PPI impairments in SC-exposed D1CT-7 mice were inhibited by standard TS therapies and D1 dopamine receptor antagonism. These findings collectively support the translational and construct validity of D1CT-7 mice with respect to TS. This article is part of a themed section on Updating Neuropathology and Neuropharmacology of Monoaminergic Systems. To view the other articles in this section visit http://onlinelibrary.wiley.com/doi/10.1111/bph.v173.13/issuetoc. © 2015 The British Pharmacological Society.

  16. 10 CFR 431.102 - Definitions concerning commercial water heaters, hot water supply boilers, and unfired hot water...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... are designed to heat water to temperatures of 180 °F or higher. Packaged boiler means a boiler that is... hour) of the heat content of the stored water and determined by the formula for S given in Section 2.10... means a water heater that heats and stores water within the appliance at a thermostatically controlled...

  17. 10 CFR 431.102 - Definitions concerning commercial water heaters, hot water supply boilers, and unfired hot water...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... designed to heat water to temperatures of 180 °F or higher. Packaged boiler means a boiler that is shipped... heat content of the stored water and determined by the formula for S given in Section 2.10 of ANSI Z21... water heater that heats and stores water within the appliance at a thermostatically controlled...

  18. 10 CFR 431.102 - Definitions concerning commercial water heaters, hot water supply boilers, and unfired hot water...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... are designed to heat water to temperatures of 180 °F or higher. Packaged boiler means a boiler that is... hour) of the heat content of the stored water and determined by the formula for S given in Section 2.10... means a water heater that heats and stores water within the appliance at a thermostatically controlled...

  19. SOLCOST. Solar Hot Water Handbook. A Simplified Design Method for Sizing and Costing Residential and Commercial Solar Service Hot Water Systems. Second Edition.

    ERIC Educational Resources Information Center

    Energy Research and Development Administration, Washington, DC. Div. of Solar Energy.

    This pamphlet offers a preview of information services available from Solcost, a research and development project. The first section explains that Solcost calculates system and costs performance for solar heated and cooled new and retrofit constructions, such as residential buildings and single zone commercial buildings. For a typical analysis,…

  20. 10 CFR 431.106 - Uniform test method for the measurement of energy efficiency of commercial water heaters and hot...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform test method for the measurement of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water heaters). 431.106 Section 431.106 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL...

  1. 10 CFR 431.106 - Uniform test method for the measurement of energy efficiency of commercial water heaters and hot...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform test method for the measurement of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water heaters). 431.106 Section 431.106 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL...

  2. 10 CFR 431.106 - Uniform test method for the measurement of energy efficiency of commercial water heaters and hot...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform test method for the measurement of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water heaters). 431.106 Section 431.106 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL...

  3. 10 CFR 431.106 - Uniform test method for the measurement of energy efficiency of commercial water heaters and hot...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform test method for the measurement of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water heaters). 431.106 Section 431.106 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL...

  4. Mineralogy of Drill Cuttings Beowawe, Dixie Valley and Roosevelt Hot Springs

    DOE Data Explorer

    Simmons, Stuart

    2017-01-25

    Mineralogical, lithological, and geospatial data of drill cuttings from exploration production wells in Beowawe, Dixie Valley and Roosvelt Hot Springs. These data support whole rock analyses for major, minor and critical elements to assess critical metals in produced fluids from Nevada and Utah geothermal fields. The samples were analyzed by x-ray diffraction (legacy data) and then checked by thin section analysis.

  5. Circulating interleukin-8 and tumor necrosis factor-α are associated with hot flashes in healthy postmenopausal women.

    PubMed

    Huang, Wan-Yu; Hsin, I-Lun; Chen, Dar-Ren; Chang, Chia-Chu; Kor, Chew-Teng; Chen, Ting-Yu; Wu, Hung-Ming

    2017-01-01

    Hot flashes have been postulated to be linked to systemic inflammation. This study aimed to investigate the relationship between hot flashes, pro-inflammatory factors, and leukocytes in healthy, non-obese postmenopausal women. In this cross-sectional study, a total of 202 women aged 45-60 years were stratified into one of four groups according to their hot-flash status: never experienced hot flashes (Group N), mild hot flashes (Group m), moderate hot flashes (Group M), and severe hot flashes (Group S). Variables measured in this study included clinical parameters, hot flash experience, leukocytes, and fasting plasma levels of nine circulating cytokines/chemokines measured by using multiplex assays. Multiple linear regression analysis was used to evaluate the associations of hot flashes with these pro-inflammatory factors. The study was performed in a hospital medical center. The mean values of leukocyte number were not different between these four groups. The hot flash status had a positive tendency toward increased levels of circulating IL-6 (P-trend = 0.049), IL-8 (P-trend < 0.001), TNF-α (P-trend = 0.008), and MIP1β (P-trend = 0.04). Multivariate linear regression analysis revealed that hot-flash severity was significantly associated with IL-8 (P-trend < 0.001) and TNFα (P-trend = 0.007) among these nine cytokines/chemokines after adjustment for age, menopausal duration, BMI and FSH. Multivariate analysis further revealed that severe hot flashes were strongly associated with a higher IL-8 (% difference, 37.19%; 95% confidence interval, 14.98,63.69; P < 0.001) and TNFα (51.27%; 6.64,114.57; P < 0.05). The present study provides evidence that hot flashes are associated with circulating IL-8 and TNF-α in healthy postmenopausal women. It suggests that hot flashes might be related to low-grade systemic inflammation.

  6. Circulating interleukin-8 and tumor necrosis factor-α are associated with hot flashes in healthy postmenopausal women

    PubMed Central

    Huang, Wan-Yu; Hsin, I-Lun; Chen, Dar-Ren; Chang, Chia-Chu; Kor, Chew-Teng; Chen, Ting-Yu

    2017-01-01

    Introduction Hot flashes have been postulated to be linked to systemic inflammation. This study aimed to investigate the relationship between hot flashes, pro-inflammatory factors, and leukocytes in healthy, non-obese postmenopausal women. Participants and design In this cross-sectional study, a total of 202 women aged 45–60 years were stratified into one of four groups according to their hot-flash status: never experienced hot flashes (Group N), mild hot flashes (Group m), moderate hot flashes (Group M), and severe hot flashes (Group S). Variables measured in this study included clinical parameters, hot flash experience, leukocytes, and fasting plasma levels of nine circulating cytokines/chemokines measured by using multiplex assays. Multiple linear regression analysis was used to evaluate the associations of hot flashes with these pro-inflammatory factors. Settings The study was performed in a hospital medical center. Results The mean values of leukocyte number were not different between these four groups. The hot flash status had a positive tendency toward increased levels of circulating IL-6 (P-trend = 0.049), IL-8 (P-trend < 0.001), TNF-α (P-trend = 0.008), and MIP1β (P-trend = 0.04). Multivariate linear regression analysis revealed that hot-flash severity was significantly associated with IL-8 (P-trend < 0.001) and TNFα (P-trend = 0.007) among these nine cytokines/chemokines after adjustment for age, menopausal duration, BMI and FSH. Multivariate analysis further revealed that severe hot flashes were strongly associated with a higher IL-8 (% difference, 37.19%; 95% confidence interval, 14.98,63.69; P < 0.001) and TNFα (51.27%; 6.64,114.57; P < 0.05). Conclusion The present study provides evidence that hot flashes are associated with circulating IL-8 and TNF-α in healthy postmenopausal women. It suggests that hot flashes might be related to low-grade systemic inflammation. PMID:28846735

  7. Handling Density Conversion in TPS.

    PubMed

    Isobe, Tomonori; Mori, Yutaro; Takei, Hideyuki; Sato, Eisuke; Tadano, Kiichi; Kobayashi, Daisuke; Tomita, Tetsuya; Sakae, Takeji

    2016-01-01

    Conversion from CT value to density is essential to a radiation treatment planning system. Generally CT value is converted to the electron density in photon therapy. In the energy range of therapeutic photon, interactions between photons and materials are dominated with Compton scattering which the cross-section depends on the electron density. The dose distribution is obtained by calculating TERMA and kernel using electron density where TERMA is the energy transferred from primary photons and kernel is a volume considering spread electrons. Recently, a new method was introduced which uses the physical density. This method is expected to be faster and more accurate than that using the electron density. As for particle therapy, dose can be calculated with CT-to-stopping power conversion since the stopping power depends on the electron density. CT-to-stopping power conversion table is also called as CT-to-water-equivalent range and is an essential concept for the particle therapy.

  8. 40 CFR Appendix A to Part 97 - Final Section 126 Rule: EGU Allocations, 2004-2007

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... NC L V SUTTON 2713 3 717 NC L V SUTTON 2713 CT2B 2 NC LEE 2709 1 129 NC LEE 2709 2 142 NC LEE 2709 3 414 NC LEE 2709 CT4 1 NC LINCOLN 7277 1 33 NC LINCOLN 7277 10 31 NC LINCOLN 7277 11 33 NC LINCOLN 7277...

  9. Diagnostic imaging in uterine incisional necrosis/dehiscence complicating cesarean section.

    PubMed

    Rivlin, Michel E; Patel, Rameshkumar B; Carroll, C Shannon; Morrison, John C

    2005-12-01

    To review the diagnostic imaging studies in patients with surgically proven uterine incisional necrosis/dehiscence complicating cesarean section and to compare these studies with the findings at surgery. Over a 6-year period, the records of 7 patients with imaging studies prior to surgery for uterine incisional necrosis/dehiscence complicating cesarean delivery were reviewed and compared with the findings at surgery. Four cases underwent computed tomography (CT) and sonography, 1 underwent CT only, and 2 underwent sonography only. Abnormal findings included abdominal free fluid in 4, pleural effusions in 3, dilated bowel in 3, possible bladder flap hematoma in 2 and single instances of liver abscess and retained products of conception. In no cases were all the studies normal, and necrosis/dehiscence was not demonstrated in any patient. Abdominal free fluid, bowel distension, pleural effusion and bladder flap hematoma seen on CT or sonogram in the postcesarean context suggest the possibility of uterine incisional necrosis/dehiscence. Magnetic resonance imaging (MRI) might then be indicated since MRI may be superior to CT in evaluating complications at the incisional site because of its multiplanar capability and greater degree of soft tissue contrast.

  10. Visualization of superparamagnetic nanoparticles in vascular tissue using XμCT and histology.

    PubMed

    Tietze, Rainer; Rahn, Helene; Lyer, Stefan; Schreiber, Eveline; Mann, Jenny; Odenbach, Stefan; Alexiou, Christoph

    2011-02-01

    In order to increase the dose of antineoplastic agents in the tumor area, the concept of magnetic drug targeting (MDT) has been developed. Magnetic nanoparticles consisting of iron oxide and a biocompatible cover layer suspended in an aqueous solution (ferrofluid) serve as carriers for chemotherapeutics being enriched by an external magnetic field after intra-arterial application in desired body compartments (i.e., tumor). We established an ex vivo model to simulate in vivo conditions in a circulating system consisting of magnetic iron oxide nanoparticles passing an intact bovine artery and being focused by an external magnetic field to study their distribution in the vessel. Micro-computed X-ray tomography (XμCT) and histology can elucidate the arrangement of these particles after application. XμCT-analysis has been performed on arterial sections after MDT in order to determine the distribution of the nanoparticles. These measurements have been carried out with a cone X-ray source and corresponding histological sections were stained with Prussian blue. It could be shown that combining XμCT and histology offers the opportunity for a better understanding of the mechanisms of nanoparticle deposition in the vascular system after MDT.

  11. Multiple sample characterization of coals and other substances by controlled-atmosphere programmed temperature oxidation

    DOEpatents

    LaCount, Robert B.

    1993-01-01

    A furnace with two hot zones holds multiple analysis tubes. Each tube has a separable sample-packing section positioned in the first hot zone and a catalyst-packing section positioned in the second hot zone. A mass flow controller is connected to an inlet of each sample tube, and gas is supplied to the mass flow controller. Oxygen is supplied through a mass flow controller to each tube to either or both of an inlet of the first tube and an intermediate portion between the tube sections to intermingle with and oxidize the entrained gases evolved from the sample. Oxidation of those gases is completed in the catalyst in each second tube section. A thermocouple within a sample reduces furnace temperature when an exothermic condition is sensed within the sample. Oxidized gases flow from outlets of the tubes to individual gas cells. The cells are sequentially aligned with an infrared detector, which senses the composition and quantities of the gas components. Each elongated cell is tapered inward toward the center from cell windows at the ends. Volume is reduced from a conventional cell, while permitting maximum interaction of gas with the light beam. Reduced volume and angulation of the cell inlets provide rapid purgings of the cell, providing shorter cycles between detections. For coal and other high molecular weight samples, from 50% to 100% oxygen is introduced to the tubes.

  12. Does Choline PET/CT Change the Management of Prostate Cancer Patients With Biochemical Failure?

    PubMed

    Goldstein, Jeffrey; Even-Sapir, Einat; Ben-Haim, Simona; Saad, Akram; Spieler, Benjamin; Davidson, Tima; Berger, Raanan; Weiss, Ilana; Appel, Sarit; Lawrence, Yaacov R; Symon, Zvi

    2017-06-01

    The FDA approved C-11 choline PET/computed tomography (CT) for imaging patients with recurrent prostate cancer in 2012. Subsequently, the 2014 NCCN guidelines have introduced labeled choline PET/CT in the imaging algorithm of patients with suspected recurrent disease. However, there is only scarce data on the impact of labeled choline PET/CT findings on disease management. We hypothesized that labeled-choline PET/CT studies showing local or regional recurrence or distant metastases will have a direct role in selection of appropriate patient management and improve radiation planning in patients with disease that can be controlled using this mode of therapy. This retrospective study was approved by the Tel Aviv Sourasky and Sheba Medical Center's Helsinki ethical review committees. Patient characteristics including age, PSA, stage, prior treatments, and pre-PET choline treatment recommendations based on NCCN guidelines were recorded. Patients with biochemical failure and without evidence of recurrence on physical examination or standard imaging were offered the option of additional imaging with labeled choline PET/CT. Treatment recommendations post-PET/CT were compared with pre-PET/CT ones. Pathologic confirmation was obtained before prostate retreatment. A nonparametric χ test was used to compare the initial and final treatment recommendations following choline PET/CT. Between June 2010 and January 2014, 34 labeled-choline PET/CT studies were performed on 33 patients with biochemical failure following radical prostatectomy (RP) (n=6), radiation therapy (RT) (n=6), brachytherapy (n=2), RP+salvage prostate fossa RT (n=14), and RP+salvage prostate fossa/lymph node RT (n=6). Median PSA level before imaging was 2 ng/mL (range, 0.16 to 79). Labeled choline PET/CT showed prostate, prostate fossa, or pelvic lymph node increased uptake in 17 studies, remote metastatic disease in 9 studies, and failed to identify the cause for biochemical failure in 7 scans.PET/CT altered treatment approach in 18 of 33 (55%) patients (P=0.05). Sixteen of 27 patients (59%) treated previously with radiation were retreated with RT and delayed or eliminated androgen deprivation therapy: 1 received salvage brachytherapy, 10 received salvage pelvic lymph node or prostate fossa irradiation, 2 brachytherapy failures received salvage prostate and lymph nodes IMRT, and 3 with solitary bone metastasis were treated with radiosurgery. Eleven of 16 patients retreated responded to salvage therapy with a significant PSA response (<0.2 ng/mL), 2 patients had partial biochemical responses, and 3 patients failed. The median duration of response was 500±447 days. Two of 6 patients with no prior RT were referred for salvage prostatic fossa RT: 1 received dose escalation for disease identified in the prostate fossa and another had inclusion of "hot" pelvic lymph nodes in the treatment volume. These early results suggest that labeled choline PET/CT imaging performed according to current NCCN guidelines may change management and improve care in prostate cancer patients with biochemical failure by identifying patients for referral for salvage radiation therapy, improving radiation planning, and delaying or avoiding use of androgen deprivation therapy.

  13. SU-E-J-221: A Novel Expansion Method for MRI Based Target Delineation in Prostate Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruiz, B; East Carolina University, Greenville, NC; Feng, Y

    Purpose: To compare a novel bladder/rectum carveout expansion method on MRI delineated prostate to standard CT and expansion based methods for maintaining prostate coverage while providing superior bladder and rectal sparing. Methods: Ten prostate cases were planned to include four trials: MRI vs CT delineated prostate/proximal seminal vesicles, and each image modality compared to both standard expansions (8mm 3D expansion and 5mm posterior, i.e. ∼8mm) and carveout method expansions (5mm 3D expansion, 4mm posterior for GTV-CTV excluding expansion into bladder/rectum followed by additional 5mm 3D expansion to PTV, i.e. ∼1cm). All trials were planned to total dose 7920 cGy viamore » IMRT. Evaluation and comparison was made using the following criteria: QUANTEC constraints for bladder/rectum including analysis of low dose regions, changes in PTV volume, total control points, and maximum hot spot. Results: ∼8mm MRI expansion consistently produced the most optimal plan with lowest total control points and best bladder/rectum sparing. However, this scheme had the smallest prostate (average 22.9% reduction) and subsequent PTV volume, consistent with prior literature. ∼1cm MRI had an average PTV volume comparable to ∼8mm CT at 3.79% difference. Bladder QUANTEC constraints were on average less for the ∼1cm MRI as compared to the ∼8mm CT and observed as statistically significant with 2.64% reduction in V65. Rectal constraints appeared to follow the same trend. Case-by-case analysis showed variation in rectal V30 with MRI delineated prostate being most favorable regardless of expansion type. ∼1cm MRI and ∼8mm CT had comparable plan quality. Conclusion: MRI delineated prostate with standard expansions had the smallest PTV leading to margins that may be too tight. Bladder/rectum carveout expansion method on MRI delineated prostate was found to be superior to standard CT based methods in terms of bladder and rectal sparing while maintaining prostate coverage. Continued investigation is warranted for further validation.« less

  14. Seasonal variation in carcass characteristics of korean cattle steers.

    PubMed

    Piao, M Y; Baik, M

    2015-03-01

    Climate temperature affects animal production. This study was conducted to evaluate whether climatic conditions affect beef carcass characteristics of Korean cattle steers. The monthly carcass characteristics of Korean cattle steers (n = 2,182,415) for 8 yr (2006 through 2013) were collected from the Korean Institute for Animal Products Quality Evaluation. Daily climate temperature (CT) and relative humidity (RH) data were collected from the Korean Meteorological Administration. Weather conditions in South Korea during summer were hot and humid, with a maximum temperature of 28.4°C and a maximum RH of 91.4%. The temperature-humidity index (THI), calculated based on CT and RH, ranges from 73 to 80 during summer. Winter in South Korea was cold, with a minimum temperature of -4.0°C and a wind-chill temperature of -6.2°C. Both marbling score (MS) and quality grade (QG) of Korean cattle steer carcasses were generally best (p<0.05) in autumn and worst in spring. A correlation analysis showed that MS and QG frequencies were not associated (p>0.05) with CT. Yield grade (YG) of Korean cattle steer carcasses was lowest (p<0.05) in winter (November to January) and highest in spring and summer (May to September). A correlation analysis revealed that YG frequency was strongly correlated (r≥0.71; p<0.01) with CT and THI values. The rib eye area, a positive YG parameter, was not associated with CT. Backfat thickness (BT), a negative YG factor, was highest in winter (November and December). The BT was strongly negatively correlated (r≤-0.74; p<0.01) with CTs. Therefore, the poor YG during winter is likely due in part to the high BT. In conclusion, YG in Korean cattle steer carcasses was worst in winter. QGs were not associated with winter or summer climatic conditions.

  15. Seasonal Variation in Carcass Characteristics of Korean Cattle Steers

    PubMed Central

    Piao, M. Y.; Baik, M.

    2015-01-01

    Climate temperature affects animal production. This study was conducted to evaluate whether climatic conditions affect beef carcass characteristics of Korean cattle steers. The monthly carcass characteristics of Korean cattle steers (n = 2,182,415) for 8 yr (2006 through 2013) were collected from the Korean Institute for Animal Products Quality Evaluation. Daily climate temperature (CT) and relative humidity (RH) data were collected from the Korean Meteorological Administration. Weather conditions in South Korea during summer were hot and humid, with a maximum temperature of 28.4°C and a maximum RH of 91.4%. The temperature-humidity index (THI), calculated based on CT and RH, ranges from 73 to 80 during summer. Winter in South Korea was cold, with a minimum temperature of −4.0°C and a wind-chill temperature of −6.2°C. Both marbling score (MS) and quality grade (QG) of Korean cattle steer carcasses were generally best (p<0.05) in autumn and worst in spring. A correlation analysis showed that MS and QG frequencies were not associated (p>0.05) with CT. Yield grade (YG) of Korean cattle steer carcasses was lowest (p<0.05) in winter (November to January) and highest in spring and summer (May to September). A correlation analysis revealed that YG frequency was strongly correlated (r≥0.71; p<0.01) with CT and THI values. The rib eye area, a positive YG parameter, was not associated with CT. Backfat thickness (BT), a negative YG factor, was highest in winter (November and December). The BT was strongly negatively correlated (r≤−0.74; p<0.01) with CTs. Therefore, the poor YG during winter is likely due in part to the high BT. In conclusion, YG in Korean cattle steer carcasses was worst in winter. QGs were not associated with winter or summer climatic conditions. PMID:25656196

  16. Computed tomographic and cross-sectional anatomy of the normal pacu (Colossoma macroponum).

    PubMed

    Carr, Alaina; Weber, E P Scott; Murphy, Chris J; Zwingenberger, Alison

    2014-03-01

    The purpose of this study was to compare and define the normal cross-sectional gross and computed tomographic (CT) anatomy for a species of boney fish to better gain insight into the use of advanced diagnostic imaging for future clinical cases. The pacu (Colossoma macropomum) was used because of its widespread presence in the aquarium trade, its relatively large body size, and its importance in the research and aquaculture settings. Transverse 0.6-mm CT images of three cadaver fish were obtained and compared to corresponding frozen cross sections of the fish. Relevant anatomic structures were identified and labeled at each level; the Hounsfield unit density of major organs was established. The images presented good anatomic detail and provide a reference for future research and clinical investigation.

  17. The effect of common imaging and hot water maceration on DNA recovery from skeletal remains.

    PubMed

    Frank, Emilie M; Mundorff, Amy Z; Davoren, Jon M

    2015-12-01

    Identifying human remains often begins with cleaning and imaging the material. Hot water maceration is used to remove adherent soft tissue from bone and radiographs are taken to better visualize osseous details. Heat and radiation are known to have harmful effects on DNA, but their ability to degrade DNA when used for cleaning and imaging has not been well studied. To better understand their individual and combined effects on the recoverability of DNA from bone, skeletal samples were subjected to (1) hot water maceration (62 °C for 45 min); (2) CT scanning (0.6mm slices, 120 kV, 10.4s); (3) X-ray (50 kVp, 150 mA, 0.03 s, 40 in); and (4) all 3 treatments combined. Forty-eight DNA samples were extracted, quantified and amplified with the AmpFLSTR(®) Identifiler(®) system. Nearly all of the processed samples had reduced RFU values relative to the unprocessed samples, indicating some amount of genetic loss. This loss did not always translate into loss of profile completeness, since only a few samples had a reduction in the number of loci detected after processing. DNA yields were not significantly reduced by any one of the processing methods, however the results indicate that the damaging effects are additive. It is possible that processing may reduce a bone's DNA reservoir and as more procedures are preformed, the pool of available genetic information might be diminished. Many intrinsic and extrinsic factors can affect the recoverability of DNA from bone. Collecting a DNA sample prior to processing avoids the negative effects from hot water maceration and radiological imaging. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Delayed hyperbaric oxygen therapy for air emboli after open heart surgery: case report and review of a success story.

    PubMed

    Niyibizi, Eva; Kembi, Guillaume Elyes; Lae, Claude; Pignel, Rodrigue; Sologashvili, Tornike

    2016-12-05

    The current case describes a rare diagnosis of iatrogenic air emboli after elective cardiopulmonary bypass that was successfully treated with delayed hyperbaric oxygen therapy, with good clinical evolution in spite of rare complications. A 35 years old male was admitted to the intensive care unit (ICU) for post-operative management after being placed on cardiopulmonary bypass (CPB) for an elective ventricular septal defect closure and aortic valvuloplasty. The patient initially presented with pathologically late awakening and was extubated 17 h after admission. Neurologic clinical status after extubation showed global aphasia, mental slowness and spatio-temporal disorientation. The injected cerebral CT scan was normal; the EEG was inconclusive (it showed metabolic encephalopathy without epileptic activity); and the cerebral MRI done 48 h after surgery showed multiple small subcortical acute ischemic lesions, mainly on the left fronto- parieto- temporo-occipital lobes. He was taken for hyperbaric oxygen therapy (HOT) over 54 h after cardiac surgery. The first session ended abruptly after 20 min when the patient suffered a generalised tonico-clonic seizure, necessitating a moderately rapid decompression, airway management, and antiepileptic treatment. In total, the patient received 7 HOT sessions over 6 days. He demonstrated full neurological recovery at 4 weeks and GOS (Glasgow Outcome Scale) of 5 out of 5 even after a long delay in initial management. Convulsions are a rare complication of HOT either due to reperfusion syndrome or hyperoxic toxicity and can be managed. Prior imaging by MRI or tympanic paracentesis (myringotomy) should not add further delay of treatment. HOT should be initiated upon late awakening and/or neurologic symptoms after CPB heart surgery, after exclusion of formal counter-indications, even if the delay exceeds 48 h.

  19. 50. PIPING FOR SUBMARINE SECTION, Y&D No. 107728 Scale 3/8' ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. PIPING FOR SUBMARINE SECTION, Y&D No. 107728 Scale 3/8' = 1'; August 26, 1929 - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  20. Co-registered perfusion SPECT/CT: utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates.

    PubMed

    Takenaka, Daisuke; Ohno, Yoshiharu; Koyama, Hisanobu; Nogami, Munenobu; Onishi, Yumiko; Matsumoto, Keiko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2010-06-01

    To directly compare the capabilities of perfusion scan, SPECT, co-registered SPECT/CT, and quantitatively and qualitatively assessed MDCT (i.e. quantitative CT and qualitative CT) for predicting postoperative clinical outcome for lung volume reduction surgery (LVRS) candidates. Twenty-five consecutive candidates (19 men and six women, age range: 42-72 years) for LVRS underwent preoperative CT and perfusion scan with SPECT. Clinical outcome of LVRS for all subjects was also assessed by determining the difference between pre- and postoperative forced expiratory volume in 1s (FEV(1)) and 6-min walking distance (6MWD). All SPECT examinations were performed on a SPECT scanner, and co-registered to thin-section CT by using commercially available software. On planar imaging, SPECT and SPECT/CT, upper versus lower zone or lobe ratios (U/Ls) were calculated from regional uptakes between upper and lower lung fields in the operated lung. On quantitatively assessed CT, U/L for all subjects was assessed from regional functional lung volumes. On qualitatively assessed CT, planar imaging, SPECT and co-registered SPECT/CT, U/Ls were assessed with a 4-point visual scoring system. To compare capabilities of predicting clinical outcome, each U/L was statistically correlated with the corresponding clinical outcome. Significantly fair or moderate correlations were observed between quantitatively and qualitatively assessed U/Ls obtained with all four methods and clinical outcomes (-0.60

  1. Video-game based therapy performed by children with cerebral palsy: a cross-over randomized controlled trial and a cross-sectional quantitative measure of physical activity.

    PubMed

    Zoccolillo, L; Morelli, D; Cincotti, F; Muzzioli, L; Gobbetti, T; Paolucci, S; Iosa, M

    2015-12-01

    Previous studies reported controversial results about the efficacy of video-game based therapy (VGT) in improving neurorehabilitation outcomes in children with cerebral palsy (CP). Primary aim was to investigate the effectiveness of VGT with respect to conventional therapy (CT) in improving upper limb motor outcomes in a group of children with CP. Secondary aim was to quantify if VGT leads children to perform a higher number of movements. A cross-over randomized controlled trial (RCT) for investigating the primary aim and a cross-sectional study for investigating the secondary aim of this study. Outpatients. clinical diagnosis of CP, age between 4 and 14 years, level of GMFC between I and IV. QI<35, severe comorbidities, incapacity to stand even with an external support. Twenty-two children with CP (6.89±1.91-year old) were enrolled in a cross-over RCT with 16 sessions of VGT (using Xbox with Kinect device) and then 16 of CT or vice versa. Upper limb functioning was assessed using the Quality of Upper Extremities Skills Test (QUEST) and hand abilities using Abilhand-kids score. According to the secondary aim of this study a secondary cross-sectional study has been performed. Eight children with CP (6.50±1.60-year old) were enrolled into a trial in which five wireless triaxial accelerometers were positioned on their forearms, legs and trunk for quantifying the physical activity during VGT vs. CT. QUEST scores significantly improved only after VGT (P=0.003), and not after CT (P=0.056). The reverse occurred for Abilhand-kids scores (P=0.165 vs. P=0.013, respectively). Quantity of performed movements was three times higher in VGT than in CT (+198%, P=0.027). VGT resulted effective in improving the motor functions of upper limb extremities in children with CP, conceivably for the increased quantity of limb movements, but failed in improving the manual abilities for performing activities of daily living which benefited more from CT. VGT performed using the X-Box with Kinect device could enhance the number of upper limb movements in children with CP during rehabilitation and in turn improving upper limb motor skills, but CT remained superior for improving performances in manual activities of daily living.

  2. Circulating leptin and adiponectin are associated with insulin resistance in healthy postmenopausal women with hot flashes.

    PubMed

    Huang, Wan-Yu; Chang, Chia-Chu; Chen, Dar-Ren; Kor, Chew-Teng; Chen, Ting-Yu; Wu, Hung-Ming

    2017-01-01

    Hot flashes have been postulated to be linked to the development of metabolic disorders. This study aimed to evaluate the relationship between hot flashes, adipocyte-derived hormones, and insulin resistance in healthy, non-obese postmenopausal women. In this cross-sectional study, a total of 151 women aged 45-60 years were stratified into one of three groups according to hot-flash status over the past three months: never experienced hot flashes (Group N), mild-to-moderate hot flashes (Group M), and severe hot flashes (Group S). Variables measured in this study included clinical parameters, hot flash experience, fasting levels of circulating glucose, lipid profiles, plasma insulin, and adipocyte-derived hormones. Multiple linear regression analysis was used to evaluate the associations of hot flashes with adipocyte-derived hormones, and with insulin resistance. The study was performed in a hospital medical center. The mean (standard deviation) of body-mass index was 22.8(2.7) for Group N, 22.6(2.6) for Group M, and 23.5(2.4) for Group S, respectively. Women in Group S displayed statistically significantly higher levels of leptin, fasting glucose, and insulin, and lower levels of adiponectin than those in Groups M and N. Multivariate linear regression analysis revealed that hot-flash severity was significantly associated with higher leptin levels, lower adiponectin levels, and higher leptin-to-adiponectin ratio. Univariate linear regression analysis revealed that hot-flash severity was strongly associated with a higher HOMA-IR index (% difference, 58.03%; 95% confidence interval, 31.00-90.64; p < 0.001). The association between hot flashes and HOMA-IR index was attenuated after adjusting for leptin or adiponectin and was no longer significant after simultaneously adjusting for leptin and adiponectin. The present study provides evidence that hot flashes are associated with insulin resistance in postmenopausal women. It further suggests that hot flash association with insulin resistance is dependent on the combination of leptin and adiponectin variables.

  3. Developing a methodology for three-dimensional correlation of PET–CT images and whole-mount histopathology in non-small-cell lung cancer

    PubMed Central

    Dahele, M.; Hwang, D.; Peressotti, C.; Sun, L.; Kusano, M.; Okhai, S.; Darling, G.; Yaffe, M.; Caldwell, C.; Mah, K.; Hornby, J.; Ehrlich, L.; Raphael, S.; Tsao, M.; Behzadi, A.; Weigensberg, C.; Ung, Y.C.

    2008-01-01

    Background Understanding the three-dimensional (3D) volumetric relationship between imaging and functional or histopathologic heterogeneity of tumours is a key concept in the development of image-guided radiotherapy. Our aim was to develop a methodologic framework to enable the reconstruction of resected lung specimens containing non-small-cell lung cancer (nsclc), to register the result in 3D with diagnostic imaging, and to import the reconstruction into a radiation treatment planning system. Methods and Results We recruited 12 patients for an investigation of radiology–pathology correlation (rpc) in nsclc. Before resection, imaging by positron emission tomography (pet) or computed tomography (ct) was obtained. Resected specimens were formalin-fixed for 1–24 hours before sectioning at 3-mm to 10-mm intervals. To try to retain the original shape, we embedded the specimens in agar before sectioning. Consecutive sections were laid out for photography and manually adjusted to maintain shape. Following embedding, the tissue blocks underwent whole-mount sectioning (4-μm sections) and staining with hematoxylin and eosin. Large histopathology slides were used to whole-mount entire sections for digitization. The correct sequence was maintained to assist in subsequent reconstruction. Using Photoshop (Adobe Systems Incorporated, San Jose, CA, U.S.A.), contours were placed on the photographic images to represent the external borders of the section and the extent of macroscopic disease. Sections were stacked in sequence and manually oriented in Photoshop. The macroscopic tumour contours were then transferred to MATLAB (The Mathworks, Natick, MA, U.S.A.) and stacked, producing 3D surface renderings of the resected specimen and embedded gross tumour. To evaluate the microscopic extent of disease, customized “tile-based” and commercial confocal panoramic laser scanning (TISSUEscope: Biomedical Photometrics, Waterloo, ON) systems were used to generate digital images of whole-mount histopathology sections. Using the digital whole-mount images and imaging software, we contoured the gross and microscopic extent of disease. Two methods of registering pathology and imaging were used. First, selected pet and ct images were transferred into Photoshop, where they were contoured, stacked, and reconstructed. After importing the pathology and the imaging contours to MATLAB, the contours were reconstructed, manually rotated, and rigidly registered. In the second method, MATLAB tumour renderings were exported to a software platform for manual registration with the original pet and ct images in multiple planes. Data from this software platform were then exported to the Pinnacle radiation treatment planning system in dicom (Digital Imaging and Communications in Medicine) format. Conclusions There is no one definitive method for 3D volumetric rpc in nsclc. An innovative approach to the 3D reconstruction of resected nsclc specimens incorporates agar embedding of the specimen and whole-mount digital histopathology. The reconstructions can be rigidly and manually registered to imaging modalities such as ct and pet and exported to a radiation treatment planning system. PMID:19008992

  4. Ultrafine nanoporous palladium-aluminum film fabricated by citric acid-assisted hot-water-treatment of aluminum-palladium alloy film

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harumoto, Takashi; Tamura, Yohei; Ishiguro, Takashi, E-mail: ishiguro@rs.noda.tus.ac.jp

    Hot-water-treatment has been adapted to fabricate ultrafine nanoporous palladium-aluminum film from aluminum-palladium alloy film. Using citric acid as a chelating agent, a precipitation of boehmite (aluminum oxide hydroxide, AlOOH) on the nanoporous palladium-aluminum film was suppressed. According to cross-sectional scanning transmission electron microscopy observations, the ligament/pore sizes of the prepared nanoporous film were considerably small (on the order of 10 nm). Since this fabrication method only requires aluminum alloy film and hot-water with chelating agent, the ultrafine nanoporous film can be prepared simply and environmentally friendly.

  5. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 4. Medical Imaging Procedures.

    PubMed

    Byrum, Russell; Keith, Lauren; Bartos, Christopher; St Claire, Marisa; Lackemeyer, Matthew G; Holbrook, Michael R; Janosko, Krisztina; Barr, Jason; Pusl, Daniela; Bollinger, Laura; Wada, Jiro; Coe, Linda; Hensley, Lisa E; Jahrling, Peter B; Kuhn, Jens H; Lentz, Margaret R

    2016-10-03

    Medical imaging using animal models for human diseases has been utilized for decades; however, until recently, medical imaging of diseases induced by high-consequence pathogens has not been possible. In 2014, the National Institutes of Health, National Institute of Allergy and Infectious Diseases, Integrated Research Facility at Fort Detrick opened an Animal Biosafety Level 4 (ABSL-4) facility to assess the clinical course and pathology of infectious diseases in experimentally infected animals. Multiple imaging modalities including computed tomography (CT), magnetic resonance imaging, positron emission tomography, and single photon emission computed tomography are available to researchers for these evaluations. The focus of this article is to describe the workflow for safely obtaining a CT image of a live guinea pig in an ABSL-4 facility. These procedures include animal handling, anesthesia, and preparing and monitoring the animal until recovery from sedation. We will also discuss preparing the imaging equipment, performing quality checks, communication methods from "hot side" (containing pathogens) to "cold side," and moving the animal from the holding room to the imaging suite.

  6. Comparative evaluation of the cadaveric, radiographic and computed tomographic anatomy of the heads of green iguana (Iguana iguana), common tegu (Tupinambis merianae) and bearded dragon (Pogona vitticeps).

    PubMed

    Banzato, Tommaso; Selleri, Paolo; Veladiano, Irene A; Martin, Andrea; Zanetti, Emanuele; Zotti, Alessandro

    2012-05-11

    Radiology and computed tomography are the most commonly available diagnostic tools for the diagnosis of pathologies affecting the head and skull in veterinary practice. Nevertheless, accurate interpretation of radiographic and CT studies requires a thorough knowledge of the gross and the cross-sectional anatomy. Despite the increasing success of reptiles as pets, only a few reports over their normal imaging features are currently available. The aim of this study is to describe the normal cadaveric, radiographic and computed tomographic features of the heads of the green iguana, tegu and bearded dragon. 6 adult green iguanas, 4 tegus, 3 bearded dragons, and, the adult cadavers of: 4 green iguana, 4 tegu, 4 bearded dragon were included in the study. 2 cadavers were dissected following a stratigraphic approach and 2 cadavers were cross-sectioned for each species. These latter specimens were stored in a freezer (-20°C) until completely frozen. Transversal sections at 5 mm intervals were obtained by means of an electric band-saw. Each section was cleaned and photographed on both sides. Radiographs of the head of each subject were obtained. Pre- and post- contrast computed tomographic studies of the head were performed on all the live animals. CT images were displayed in both bone and soft tissue windows. Individual anatomic structures were first recognised and labelled on the anatomic images and then matched on radiographs and CT images. Radiographic and CT images of the skull provided good detail of the bony structures in all species. In CT contrast medium injection enabled good detail of the soft tissues to be obtained in the iguana whereas only the eye was clearly distinguishable from the remaining soft tissues in both the tegu and the bearded dragon. The results provide an atlas of the normal anatomical and in vivo radiographic and computed tomographic features of the heads of lizards, and this may be useful in interpreting any imaging modality involving these species.

  7. Comparative evaluation of the cadaveric, radiographic and computed tomographic anatomy of the heads of green iguana (Iguana iguana) , common tegu ( Tupinambis merianae) and bearded dragon ( Pogona vitticeps)

    PubMed Central

    2012-01-01

    Background Radiology and computed tomography are the most commonly available diagnostic tools for the diagnosis of pathologies affecting the head and skull in veterinary practice. Nevertheless, accurate interpretation of radiographic and CT studies requires a thorough knowledge of the gross and the cross-sectional anatomy. Despite the increasing success of reptiles as pets, only a few reports over their normal imaging features are currently available. The aim of this study is to describe the normal cadaveric, radiographic and computed tomographic features of the heads of the green iguana, tegu and bearded dragon. Results 6 adult green iguanas, 4 tegus, 3 bearded dragons, and, the adult cadavers of : 4 green iguana, 4 tegu, 4 bearded dragon were included in the study. 2 cadavers were dissected following a stratigraphic approach and 2 cadavers were cross-sectioned for each species. These latter specimens were stored in a freezer (−20°C) until completely frozen. Transversal sections at 5 mm intervals were obtained by means of an electric band-saw. Each section was cleaned and photographed on both sides. Radiographs of the head of each subject were obtained. Pre- and post- contrast computed tomographic studies of the head were performed on all the live animals. CT images were displayed in both bone and soft tissue windows. Individual anatomic structures were first recognised and labelled on the anatomic images and then matched on radiographs and CT images. Radiographic and CT images of the skull provided good detail of the bony structures in all species. In CT contrast medium injection enabled good detail of the soft tissues to be obtained in the iguana whereas only the eye was clearly distinguishable from the remaining soft tissues in both the tegu and the bearded dragon. Conclusions The results provide an atlas of the normal anatomical and in vivo radiographic and computed tomographic features of the heads of lizards, and this may be useful in interpreting any imaging modality involving these species. PMID:22578088

  8. 40 CFR 52.2120 - Identification of plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Section II Sulfuric Acid Manufacturing 2/28/1986 2/17/1987 52 FR 4772 Section III Kraft Pulp and Paper.../1987 52 FR 4772 Section V Cotton Gins 10/26/2001 5/7/2002 67 FR 30594 Section VI Hot Mix Asphalt.../1990 2/4/1992 57 FR 4158 Part C Surface Coating of Paper, Vinyl, and Fabric 8/24/1990 2/4/1992 57 FR...

  9. On the radiobiological impact of metal artifacts in head-and-neck IMRT in terms of tumor control probability (TCP) and normal tissue complication probability (NTCP).

    PubMed

    Kim, Yusung; Tomé, Wolfgang A

    2007-11-01

    To investigate the effects of distorted head-and-neck (H&N) intensity-modulated radiation therapy (IMRT) dose distributions (hot and cold spots) on normal tissue complication probability (NTCP) and tumor control probability (TCP) due to dental-metal artifacts. Five patients' IMRT treatment plans have been analyzed, employing five different planning image data-sets: (a) uncorrected (UC); (b) homogeneous uncorrected (HUC); (c) sinogram completion corrected (SCC); (d) minimum-value-corrected (MVC); and (e) streak-artifact-reduction including minimum-value-correction (SAR-MVC), which has been taken as the reference data-set. The effects on NTCP and TCP were evaluated using the Lyman-NTCP model and the Logistic-TCP model, respectively. When compared to the predicted NTCP obtained using the reference data-set, the treatment plan based on the original CT data-set (UC) yielded an increase in NTCP of 3.2 and 2.0% for the spared parotid gland and the spinal cord, respectively. While for the treatment plans based on the MVC CT data-set the NTCP increased by a 1.1% and a 0.1% for the spared parotid glands and the spinal cord, respectively. In addition, the MVC correction method showed a reduction in TCP for target volumes (MVC: delta TCP = -0.6% vs. UC: delta TCP = -1.9%) with respect to that of the reference CT data-set. Our results indicate that the presence of dental-metal-artifacts in H&N planning CT data-sets has an impact on the estimates of TCP and NTCP. In particular dental-metal-artifacts lead to an increase in NTCP for the spared parotid glands and a slight decrease in TCP for target volumes.

  10. Incremental Role of Mammography in the Evaluation of Gynecomastia in Men Who Have Undergone Chest CT.

    PubMed

    Sonnenblick, Emily B; Salvatore, Mary; Szabo, Janet; Lee, Karen A; Margolies, Laurie R

    2016-08-01

    The purpose of this study was to determine whether additional breast imaging is clinically valuable in the evaluation of patients with gynecomastia incidentally observed on CT of the chest. In a retrospective analysis, 62 men were identified who had a mammographic diagnosis of gynecomastia and had also undergone CT within 8 months (median, 2 months). We compared the imaging findings of both modalities and correlated them with the clinical outcome. Gynecomastia was statistically significantly larger on mammograms than on CT images; however, there was a high level of concordance in morphologic features and distribution of gynecomastia between mammography and CT. In only one case was gynecomastia evident on mammographic but not CT images, owing to cachexia. Two of the 62 men had ductal carcinoma, which was obscured by gynecomastia. Both of these patients had symptoms suggesting malignancy. The appearance of gynecomastia on CT scans and mammograms was highly correlated. Mammography performed within 8 months of CT is unlikely to reveal cancer unless there is a suspicious clinical finding or a breast mass eccentric to the nipple. Men with clinical symptoms of gynecomastia do not need additional imaging with mammography to confirm the diagnosis if they have undergone recent cross-sectional imaging.

  11. A calibration loop to test hot-wire response under supercritical conditions

    NASA Astrophysics Data System (ADS)

    Radulović, Ivana; Vukoslavčević, P. V.; Wallace, J. M.

    2004-11-01

    A calibration facility to test the response of hot-wires in CO2 flow under supercritical conditions has been designed and constructed. It is capable of inducing variable speeds at different temperatures and pressures in the ranges of 0.15 - 2 m/s, 15 - 70 deg. C and 1 - 100 bar. The facility is designed as a closed loop with a test section, pump, electrical heater, DC motor and different regulating and measuring devices. The test section is a small tunnel, with a diffuser, honeycomb, screens and a nozzle to provide a uniform flow with a low turbulence level. The speed variation is created by a sealed, magnetic driven gear pump, with a variable rpm DC motor. Using the electrical heater and regulating the amount of CO2 in the facility, the desired temperature and pressure can be reached. The dimensions of the instalation are minimized to reduce the heat, pump power required, and CO2 consumption and to optimize safety. Preliminary testing of a single hot-wire velocity sensor at constant pressure (80 bar) and variable speed and temperature will be briefly described. The hot-wire probes calibrated in this loop will be used to measure turbulence properties in supercritical CO2 in support of improved designs of nuclear reactors to be cooled by supercritical fluids.

  12. Renovation of the hot press in the Plutonium Experimental Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Congdon, J.W.; Nelson, G.H.

    1990-03-05

    The Plutonium Experimental Facility (PEF) will be used to develop a new fuel pellet fabrication process and to evaluate equipment upgrades. The facility was used from 1978 until 1982 to optimize the parameters for fuel pellet production using a process which was developed at Los Alamos National Laboratory. The PEF was shutdown and essentially abandoned until mid-1987 when the facility renovations were initiated by the Actinide Technology Section (ATS) of SRL. A major portion of the renovation work was related to the restart of the hot press system. This report describes the renovations and modifications which were required to restartmore » the PEF hot press. The primary purpose of documenting this work is to help provide a basis for Separations to determine the best method of renovating the hot press in the Plutonium Fuel Fabrication (PuFF) facility. This report also includes several SRL recommendations concerning the renovation and modification of the PuFF hot press. 4 refs.« less

  13. Learning of Cross-Sectional Anatomy Using Clay Models

    ERIC Educational Resources Information Center

    Oh, Chang-Seok; Kim, Ji-Young; Choe, Yeon Hyeon

    2009-01-01

    We incorporated clay modeling into gross anatomy and neuro-anatomy courses to help students understand cross-sectional anatomy. By making clay models, cutting them and comparing cut surfaces to CT and MR images, students learned how cross-sectional two-dimensional images were created from three-dimensional structure of human organs. Most students…

  14. Lung cancer mimicking lung abscess formation on CT images.

    PubMed

    Taira, Naohiro; Kawabata, Tsutomu; Gabe, Atsushi; Ichi, Takaharu; Kushi, Kazuaki; Yohena, Tomofumi; Kawasaki, Hidenori; Yamashiro, Toshimitsu; Ishikawa, Kiyoshi

    2014-01-01

    Male, 64 FINAL DIAGNOSIS: Lung pleomorphic carcinoma Symptoms: Cough • fever - Clinical Procedure: - Specialty: Oncology. Unusual clinical course. The diagnosis of lung cancer is often made based on computed tomography (CT) image findings if it cannot be confirmed on pathological examinations, such as bronchoscopy. However, the CT image findings of cancerous lesions are similar to those of abscesses.We herein report a case of lung cancer that resembled a lung abscess on CT. We herein describe the case of 64-year-old male who was diagnosed with lung cancer using surgery. In this case, it was quite difficult to distinguish between the lung cancer and a lung abscess on CT images, and a lung abscess was initially suspected due to symptoms, such as fever and coughing, contrast-enhanced CT image findings showing a ring-enhancing mass in the right upper lobe and the patient's laboratory test results. However, a pathological diagnosis of lung cancer was confirmed according to the results of a rapid frozen section biopsy of the lesion. This case suggests that physicians should not suspect both a lung abscesses and malignancy in cases involving masses presenting as ring-enhancing lesions on contrast-enhanced CT.

  15. Laboratory Measurements of Charge Transfer on Atomic Hydrogen at Thermal Energies

    NASA Technical Reports Server (NTRS)

    Havener, C. C.; Vane, C. R.; Krause, H. F.; Stancil, P. C.; Mroczkowski, T.; Savin, D. W.

    2002-01-01

    We describe our ongoing program to measure velocity dependent charge transfer (CT) cross sections for selected ions on atomic hydrogen using the ion-aloin merged-beams apparatus at Oak Ridge Natioiial Laboralory. Our focus is on those ions for which CT plays an important role in determining the ionization structure, line emis sion, and thermal structure of observed cosmic photoionized plasmas.

  16. Ultrafast CT scanning of an oak log for internal defects

    Treesearch

    Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder

    1989-01-01

    Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...

  17. Genetic polymorphisms, hormone levels, and hot flashes in midlife women.

    PubMed

    Schilling, Chrissy; Gallicchio, Lisa; Miller, Susan R; Langenberg, Patricia; Zacur, Howard; Flaws, Jodi A

    2007-06-20

    Hot flashes disrupt the lives of millions of women each year. Although hot flashes are a public health concern, little is known about risk factors that predispose women to hot flashes. Thus, the objective of this study was to examine whether sex steroid hormone levels and genetic polymorphisms in hormone biosynthesis and degradation enzymes are associated with the risk of hot flashes. In a cross-sectional study design, midlife women aged 45-54 years (n=639) were recruited from Baltimore and its surrounding counties. Participants completed a questionnaire and donated a blood sample for steroid hormone analysis and genotyping. The associations between genetic polymorphisms and hormone levels, as well as the associations between genetic polymorphisms, hormone levels, and hot flashes were examined using statistical models. A polymorphism in CYP1B1 was associated with lower dehydroepiandrosterone-sulfate (DHEA-S) and progesterone levels, while a polymorphism in CYP19 (aromatase) was associated with higher testosterone and DHEA-S levels. Lower progesterone and sex hormone binding globulin levels, lower free estradiol index, and a higher ratio of total androgens to total estrogens were associated with the experiencing of hot flashes. A polymorphism in CYP1B1 and a polymorphism in 3betaHSD were both associated with hot flashes. Some genetic polymorphisms may be associated with altered levels of hormones in midlife women. Further, selected genetic polymorphisms and altered hormone levels may be associated with the risk of hot flashes in midlife women.

  18. Anatomic characteristics of ruptured abdominal aortic aneurysm on conventional CT scans: Implications for rupture risk.

    PubMed

    Fillinger, Mark F; Racusin, Jessica; Baker, Robert K; Cronenwett, Jack L; Teutelink, Arno; Schermerhorn, Marc L; Zwolak, Robert M; Powell, Richard J; Walsh, Daniel B; Rzucidlo, Eva M

    2004-06-01

    The purpose of this study was to analyze anatomic characteristics of patients with ruptured abdominal aortic aneurysms (AAAs), with conventional two-dimensional computed tomography (CT), including comparison with control subjects matched for age, gender, and size. Records were reviewed to identify all CT scans obtained at Dartmouth-Hitchcock Medical Center or referring hospitals before emergency AAA repair performed because of rupture or acute severe pain (RUP group). CT scans obtained before elective AAA repair (ELEC group) were reviewed for age and gender match with patients in the RUP group. More than 40 variables were measured on each CT scan. Aneurysm diameter matching was achieved by consecutively deleting the largest RUP scan and the smallest ELEC scan to prevent bias. CT scans were analyzed for 259 patients with AAAs: 122 RUP and 137 ELEC. Patients were well matched for age, gender, and other demographic variables or risk factors. Maximum AAA diameter was significantly different in comparisons of all patients (RUP, 6.5 +/- 2 cm vs ELEC, 5.6 +/- 1 cm; P <.0001), and mean diameter of ruptured AAAs was 5 mm smaller in female patients (6.1 +/- 2 cm vs 6.6 +/- 2 cm; P =.007). Two hundred patients were matched for diameter, gender, and age (100 from each group; maximum AAA diameter, 6.0 +/- 1 cm vs 6.0 +/- 1 cm). Analysis of diameter-matched AAAs indicated that most variables were statistically similar in the two groups, including infrarenal neck length (17 +/- 1 mm vs 19 +/- 1 mm; P =.3), maximum thrombus thickness (25 +/- 1 mm vs 23 +/- 1 mm, P =.4), and indices of body habitus, such as [(maximum AAA diameter)/(normal suprarenal aorta diameter)] or [(maximum AAA diameter)/(L3 transverse diameter)]. Multivariate analysis controlling for gender indicated that the most significant variables for rupture were aortic tortuosity (odds ratio [OR] 3.3, indicating greater risk with no or mild tortuosity), diameter asymmetry (OR, 3.2 for a 1-cm difference in major-minor axis), and current smoking (OR, 2.7, with the greater risk in current smokers). When matched for age, gender, and diameter, ruptured AAAs tend to be less tortuous, yet have greater cross-sectional diameter asymmetry. On conventional two-dimensional CT axial sections, it appears that when diameter asymmetry is associated with low aortic tortuosity, the larger diameter on axial sections more accurately reflects rupture risk, and when diameter asymmetry is associated with moderate or severe aortic tortuosity, the smaller diameter on axial sections more accurately reflects rupture risk. Current smoking is significantly associated with rupture, even when controlling for gender and AAA anatomy.

  19. Stirling engine - Approach for long-term durability assessment

    NASA Technical Reports Server (NTRS)

    Tong, Michael T.; Bartolotta, Paul A.; Halford, Gary R.; Freed, Alan D.

    1992-01-01

    The approach employed by NASA Lewis for the long-term durability assessment of the Stirling engine hot-section components is summarized. The approach consists of: preliminary structural assessment; development of a viscoplastic constitutive model to accurately determine material behavior under high-temperature thermomechanical loads; an experimental program to characterize material constants for the viscoplastic constitutive model; finite-element thermal analysis and structural analysis using a viscoplastic constitutive model to obtain stress/strain/temperature at the critical location of the hot-section components for life assessment; and development of a life prediction model applicable for long-term durability assessment at high temperatures. The approach should aid in the provision of long-term structural durability and reliability of Stirling engines.

  20. Life prediction and constitutive models for engine hot section anisotropic materials

    NASA Technical Reports Server (NTRS)

    Swanson, G. A.

    1984-01-01

    The development of directionally solidified and single crystal alloys is perhaps the most important recent advancement in hot section materials technology. The objective is to develop knowledge that enables the designer to improve anisotropic gas turbine parts to their full potential. Two single crystal alloys selected were PWA 1480 and Alloy 185. The coatings selected were an overlay coating, PWA 286, and an aluminide diffusion coating, PWA 273. The constitutive specimens were solid and cylindrical; the fatigue specimens were hollow and cylindrical. Two thicknesses of substrate are utilized. Specimens of both thickness (0.4 and 1.5 mm) will be coated and then tested for tensile, creep, and fatigue properties.

  1. Turbine Engine Hot Section Technology (HOST)

    NASA Technical Reports Server (NTRS)

    1983-01-01

    A two-day workshop on the research and plans for turbine engine hot section durability problems was held on October 25 and 26, 1983, at the NASA Lewis Research Center. Presentations were made during six sessions, including structural analysis, fatigue and fracture, surface protective coatings, combustion, turbine heat transfer, and instrumentation, that dealt with the thermal and fluid environment around liners, blades, and vanes, and with material coatings, constitutive behavior, stress-strain response, and life prediction methods for the three components. The principal objective of each session was to disseminate the research results to date, along with future plans, in each of the six areas. Contract and government researchers presented results of their work.

  2. Characterization of compact-toroid injection during formation, translation, and field penetration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsumoto, T., E-mail: cstd14003@g.nihon-u.ac.jp; Sekiguchi, J.; Asai, T.

    2016-11-15

    We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation,more » ejection/translation from the MCPG, and penetration into transverse magnetic fields.« less

  3. Design of free-space optical transmission system in computer tomography equipment

    NASA Astrophysics Data System (ADS)

    Liu, Min; Fu, Weiwei; Zhang, Tao

    2018-04-01

    Traditional computer tomography (CT) based on capacitive coupling cannot satisfy the high data rate transmission requirement. We design and experimentally demonstrate a free-space optical transmission system for CT equipment at a data rate of 10 Gb / s. Two interchangeable sections of 12 pieces of fiber with equal length is fabricated and tested by our designed laser phase distance measurement system. By locating the 12 collimators in the edge of the circle wheel evenly, the optical propagation characteristics for the 12 wired and wireless paths are similar, which can satisfy the requirement of high-speed CT transmission system. After bit error rate (BER) measurement in several conditions, the BER performances are below the value of 10 - 11, which has the potential in the future application scenario of CT equipment.

  4. [µCT analysis of mandibular molars before and after instrumentation by Reciproc files].

    PubMed

    Ametrano, Gianluca; Riccitiello, Francesco; Amato, Massimo; Formisano, Anna; Muto, Massimo; Grassi, Roberta; Valletta, Alessandra; Simeone, Michele

    2013-01-01

    Cleaning and shaping are important section for the root canal treatment. A number of different methodologies have been developed to overcome these problems, including the introduction of rotary instruments nickel-titanium (NiTi). In endodontics NiTi have been shown to significantly reduce procedural errors compared to manual techniques of instrumentation. The efficiency of files is related to many factor. Although previous investigations that have used µCT analysis were hampered by insufficient resolution or projection incorrect. The new generation of μCT performance best offer, as micron resolution and accurate measurement software for evaluating the accurate anatomy of the root canal. The aim the paper was to evaluate the efficiency of Reciproc files in root canal treatment, evaluated before and after instrumentation by using μ-CT analysis.

  5. Quantitative CT scans of lung parenchymal pathology in premature infants ages 0-6 years.

    PubMed

    Spielberg, David R; Walkup, Laura L; Stein, Jill M; Crotty, Eric J; Rattan, Mantosh S; Hossain, Md Monir; Brody, Alan S; Woods, Jason C

    2018-03-01

    Bronchopulmonary dysplasia (BPD) is a common, heterogeneous disease in premature infants. We hypothesized that quantitative CT techniques could assess lung parenchymal heterogeneity in BPD patients across a broad age range and demonstrate how pathologies change over time. A cross-sectional, retrospective study of children age 0-6 years with non-contrast chest CT scans was conducted. BPD subjects met NICHD/NHLBI diagnostic criteria for BPD and were excluded for congenital lung/airway abnormalities or other known/suspected pulmonary diagnoses; control subjects were not premature and had normal CT scan findings. Radiologic opacities, lucencies, and spatial heterogeneity were quantified via: 1) thresholding using CT-attenuation (HU); 2) manual segmentation; and 3) Ochiai reader-scoring system. Clinical outcomes included BPD severity by NICHD/NHLBI criteria, respiratory support at NICU discharge, wheezing, and respiratory exacerbations. Heterogeneity (standard deviation) of lung attenuation in BPD was significantly greater than in controls (difference 36.4 HU [26.1-46.7 HU], P < 0.001); the difference between the groups decreased 0.58 HU per month of age (0.08-1.07 HU per month, P = 0.02). BPD patients had greater amounts of opacities and lucencies than controls except with automated quantification of lucencies. Cross-sectionally, lucencies per Ochiai score and opacities per manual segmentation decreased with time. No approach measured a statistically significant relationship to BPD clinical severity. Opacities, lucencies, and overall heterogeneity of lungs via quantitative CT can distinguish BPD patients from healthy controls, and these abnormalities decrease with age across BPD patients. Defining BPD severity by clinical outcomes such as respiratory support at several time points (vs a single time point, per current guidelines) may be meaningful. © 2017 Wiley Periodicals, Inc.

  6. Sci-Thur PM – Colourful Interactions: Highlights 07: Canadian Computed Tomography Survey: National Diagnostic Reference Levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wardlaw, Graeme M; Martel, Narine

    Purpose: The Canadian Computed (CT) Tomography Survey sought to collect CT technology and dose index data (CTDI and DLP) at the national level in order to establish national diagnostic reference levels (DRLs) for seven common CT examinations of standard-sized adults and pediatric patients. Methods: A single survey booklet (consisting of four sections) was mailed to and completed for each participating CT scanner. Survey sections collected data on (i) General facility and scanner information, (ii) routine protocols (as available), (iii) individual patient data (as applied) and (iv) manual CTDI measurements. Results: Dose index (CTDIvol and DLP) and associated patient data frommore » 24 280 individual patient exam sequences was analyzed for seven common CT examinations performed in Canada: Adult Head, Chest, Abdomen/Pelvis, and Chest/Abdomen/Pelvis, and Pediatric Head, Chest, and Abdomen. Pediatric examination data was sub-divided into three age ranges: 0–3, 3–7 and 7–13 years. DRLs (75th percentile of dose index distributions) were found for all thirteen groups. Further analysis also permitted segmentation of examination data into 8 sub-groups, whose dose index data was displayed along with group histograms – showing relative contribution of axial vs. helical, contrast use (C+ vs. C-), and application of fixed current vs. dose reduction (DR) – 75th percentiles of DR sub-groups were, in almost all cases, lower than whole group (examination) DRLs. Conclusions: The analysis and summaries presented in the pending survey report can serve to aid local CT imaging optimization efforts within Canada and also contribute further to international efforts in radiation protection of patients.« less

  7. Deep 3D convolution neural network for CT brain hemorrhage classification

    NASA Astrophysics Data System (ADS)

    Jnawali, Kamal; Arbabshirani, Mohammad R.; Rao, Navalgund; Patel, Alpen A.

    2018-02-01

    Intracranial hemorrhage is a critical conditional with the high mortality rate that is typically diagnosed based on head computer tomography (CT) images. Deep learning algorithms, in particular, convolution neural networks (CNN), are becoming the methodology of choice in medical image analysis for a variety of applications such as computer-aided diagnosis, and segmentation. In this study, we propose a fully automated deep learning framework which learns to detect brain hemorrhage based on cross sectional CT images. The dataset for this work consists of 40,367 3D head CT studies (over 1.5 million 2D images) acquired retrospectively over a decade from multiple radiology facilities at Geisinger Health System. The proposed algorithm first extracts features using 3D CNN and then detects brain hemorrhage using the logistic function as the last layer of the network. Finally, we created an ensemble of three different 3D CNN architectures to improve the classification accuracy. The area under the curve (AUC) of the receiver operator characteristic (ROC) curve of the ensemble of three architectures was 0.87. Their results are very promising considering the fact that the head CT studies were not controlled for slice thickness, scanner type, study protocol or any other settings. Moreover, the proposed algorithm reliably detected various types of hemorrhage within the skull. This work is one of the first applications of 3D CNN trained on a large dataset of cross sectional medical images for detection of a critical radiological condition

  8. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    PubMed Central

    2011-01-01

    Background Chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT), appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer Materials and methods A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Results Rib fracture was identified on follow-up CT in 41 patients (23.2%). Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months). Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%), of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Conclusion Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present. PMID:21995807

  9. [Virtual otoscopy--technique, indications and initial experiences with multislice spiral CT].

    PubMed

    Klingebiel, R; Bauknecht, H C; Lehmann, R; Rogalla, P; Werbs, M; Behrbohm, H; Kaschke, O

    2000-11-01

    We report the standardized postprocessing of high-resolution CT data acquired by incremental CT and multi-slice CT in patients with suspected middle ear disorders to generate three-dimensional endoluminal views known as virtual otoscopy. Subsequent to the definition of a postprocessing protocol, standardized endoluminal views of the middle ear were generated according to their otological relevance. The HRCT data sets of 26 ENT patients were transferred to a workstation and postprocessed to 52 virtual otoscopies. Generation of predefined endoluminal views from the HRCT data sets was possible in all patients. Virtual endoscopic views added meaningful information to the primary cross-sectional data in patients suffering from ossicular pathology, having contraindications for invasive tympanic endoscopy or being assessed for surgery of the tympanic cavity. Multi slice CT improved the visualization of subtle anatomic details such as the stapes suprastructure and reduced the scanning time. Virtual endoscopy allows for the non invasive endoluminal visualization of various tympanic lesions. Use of the multi-slice CT technique reduces the scanning time and improves image quality in terms of detail resolution.

  10. Online course design for teaching critical thinking.

    PubMed

    Schaber, Patricia; Shanedling, Janet

    2012-01-01

    Teaching critical thinking (CT) skills, a goal in higher education, is seldom considered in the primary design of either classroom or online courses, and is even less frequently measured in student learning. In health professional education, CT along with clinical reasoning skills is essential for the development of clinical practitioners. This study, measuring CT skill development in an online theory course, supports using a cyclical course design to build higher level processes in student thinking. Eighty-six Masters of Occupational Therapy students in four sections of an occupation-based theory course were evaluated on elements in the Paul and Elder CT Model throughout the course and surveyed for their perceptions in their ability to think critically at course completion. Results of this study demonstrated that the online theory course design contributed to improving critical thinking skills and student's perceived CT skill development as applicable to their future professional practice. In a focus group, eight students identified four effective course design features that contributed to their CT skill development: highly structured learning, timely feedback from instructor, repetition of assignments, and active engagement with the material.

  11. Paleoradiology: advanced CT in the evaluation of nine Egyptian mummies.

    PubMed

    Hoffman, Heidi; Torres, William E; Ernst, Randy D

    2002-01-01

    Axial thin-collimation state-of-the-art spiral computed tomography (CT) was combined with sagittal and coronal reformatting, three-dimensional (3D) reconstruction, and virtual "fly-through" techniques to nondestructively study nine Egyptian mummies. These techniques provided important paleopathologic and historical information about mummification techniques, depicted anatomy in the most informative imaging plane, illustrated the soft-tissue preservation and physical appearance of mummies in superb detail, and generated an intriguing virtual tour through hollow mummified remains without harming the specimens themselves. Images generated with these methods can help archaeologists and Egyptologists understand these fascinating members of mankind and can serve as adjunct visual aids for laypersons who are interested in mummies. CT has emerged as the imaging modality of choice for the examination of Egyptian mummies due to its noninvasive cross-sectional nature and inherently superior contrast and spatial resolution. As multi-detector row CT and postprocessing tools evolve, the capabilities and applications of CT will continue to proliferate, attesting to the expanded versatility and utility of CT as a noninvasive research tool in the multidisciplinary study of Egyptian mummies. Copyright RSNA, 2002

  12. Evaluation of a drainage blanket in an asphalt shoulder section : interim report.

    DOT National Transportation Integrated Search

    1974-02-01

    The aim of this research project was to develop a permeable, yet stable, hot mix asphaltic drainage system for a typical pavement section. Development of such systems should provide the Department with effective means of draining water from highway b...

  13. Chest tomosynthesis: technical principles and clinical update.

    PubMed

    Dobbins, James T; McAdams, H Page

    2009-11-01

    Digital tomosynthesis is a radiographic technique that can produce an arbitrary number of section images of a patient from a single pass of the X-ray tube. It utilizes a conventional X-ray tube, a flat-panel detector, a computer-controlled tube mover, and special reconstruction algorithms to produce section images. While it does not have the depth resolution of computed tomography (CT), tomosynthesis provides some of the tomographic benefits of CT but at lower cost and radiation dose than CT. Compared to conventional chest radiography, chest tomosynthesis results in improved visibility of normal structures such as vessels, airway and spine. By reducing visual clutter from overlying normal anatomy, it also enhances detection of small lung nodules. This review article outlines the components of a tomosynthesis system, discusses results regarding improved lung nodule detection from the recent literature, and presents examples of nodule detection from a clinical trial in human subjects. Possible implementation strategies for use in clinical chest imaging are discussed.

  14. Malignant external otitis: early scintigraphic detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strashun, A.M.; Nejatheim, M.; Goldsmith, S.J.

    1984-02-01

    Pseudomonas otitis externa in elderly diabetics may extend aggressively to adjacent bone, cranial nerves, meninges, and vessels, leading to a clinical diagnosis of ''malignant'' external otitis. Early diagnosis is necessary for successful treatment. This study compares the findings of initial radiographs, thin-section tomography of temporal bone, CT scans of head and neck, technetium-99m methylene diphosphonate (MDP) and gallium-67 citrate scintigraphy, and single-photon emission computed tomography (SPECT) for detection of temporal bone osteomylitis in ten patients fulfilling the clinical diagnostic criteria of malignant external otitis. Skull radiographs were negative in all of the eight patients studied. Thin-section tomography was positive inmore » one of the seven patients studied using this modality. CT scanning suggested osteomyelitis in three of nine patients. Both Tc-99m and Ga-67 citrate scintigraphy were positive in 10 of 10 patients. These results suggest that technetium and gallium scintigraphy are more sensitive than radiographs and CT scans for early detection of malignant external otitis.« less

  15. CT analysis of nasal volume changes after surgically-assisted rapid maxillary expansion.

    PubMed

    Tausche, Eve; Deeb, Wayel; Hansen, Lars; Hietschold, Volker; Harzer, Winfried; Schneider, Matthias

    2009-07-01

    Aim of this study was to detect the changes in nasal volume due to bone-borne, surgically-assisted rapid palatal expansion (RPE) with the Dresden Distractor using computed tomography (CT). 17 patients (mean age 28.8) underwent axial CT scanning before and 6 months after RPE. The nasal bone width was examined in the coronal plane. Cross-sectional images of the nasal cavity were taken of the area surrounding the piriform aperture, choanae and in between. Bony nasal volume was computed by connecting the three cross-sectional areas. All but two patients showed a 4.8% increase in nasal volume (SD 4.6%). The highest value, 33.3% (SD 45.1%), was measured anteriorly at the level of the nasal floor. This correlated with the midpalatal suture's V-shaped opening. There was no significant correlation between an increase in nasal volume and transverse dental arch expansion. As most of the air we breathe passes the lower nasal floor, an improvement in nasal breathing is likely.

  16. Cross-sectional study on risk factors of HIV among female commercial sex workers in Cambodia.

    PubMed Central

    Ohshige, K.; Morio, S.; Mizushima, S.; Kitamura, K.; Tajima, K.; Ito, A.; Suyama, A.; Usuku, S.; Saphonn, V.; Heng, S.; Hor, L. B.; Tia, P.; Soda, K.

    2000-01-01

    To describe epidemiological features on HIV prevalence among female commercial sex workers (CSWs), a cross-sectional study on sexual behaviour and serological prevalence was carried out in Cambodia. The CSWs were interviewed on their demographic characters and behaviour and their blood samples were taken for testing on sexually transmitted diseases, including HIV, Chlamydia trachomatis, syphilis, and hepatitis B. Associations between risk factors and HIV seropositivity were analysed. High seroprevalence of HIV and Chlamydia trachomatis IgG antibody (CT-IgG-Ab) was shown among the CSWs (54 and 81.7%, respectively). Univariate logistic regression analyses showed an association between HIV seropositivity and age, duration of prostitution, the number of clients per day and CT-IgG-Ab. Especially, high-titre chlamydial seropositivity showed a strong significant association with HIV prevalence. In multiple logistic regression analyses, CT-IgG-Ab with higher titre was significantly independently related to HIV infection. These suggest that existence of Chlamydia trachomatis is highly related to HIV prevalence. PMID:10722142

  17. A simulation-based study on the influence of beam hardening in X-ray computed tomography for dimensional metrology.

    PubMed

    Lifton, Joseph J; Malcolm, Andrew A; McBride, John W

    2015-01-01

    X-ray computed tomography (CT) is a radiographic scanning technique for visualising cross-sectional images of an object non-destructively. From these cross-sectional images it is possible to evaluate internal dimensional features of a workpiece which may otherwise be inaccessible to tactile and optical instruments. Beam hardening is a physical process that degrades the quality of CT images and has previously been suggested to influence dimensional measurements. Using a validated simulation tool, the influence of spectrum pre-filtration and beam hardening correction are evaluated for internal and external dimensional measurements. Beam hardening is shown to influence internal and external dimensions in opposition, and to have a greater influence on outer dimensions compared to inner dimensions. The results suggest the combination of spectrum pre-filtration and a local gradient-based surface determination method are able to greatly reduce the influence of beam hardening in X-ray CT for dimensional metrology.

  18. Importance of 18F-FDG PET/CT to select patients with nonresectable colorectal liver metastases for liver transplantation.

    PubMed

    Grut, Harald; Revheim, Mona-Elisabeth; Line, Pål-Dag; Dueland, Svein

    2018-04-20

    The aim of this study was to evaluate fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT for the selection of patients with nonresectable colorectal liver metastases (NCLM) for liver transplantation (LT). In the secondary cancer study, we reported an improved 5-year overall survival in patients treated with LT for NCLM (56%) compared with chemotherapy (9%). However, many patients were rejected for LT owing to the detection of extrahepatic disease at preoperative imaging. F-FDG PET/CT and contrast-enhanced computed tomography (ceCT) examinations before tentative LT for NCLM were assessed, and findings contraindicating LT were registered. Maximum, mean and peak standardized uptake values; tumor-to-background ratio; metabolic tumor volume; and total lesion glycolysis were measured and calculated for all liver metastases. Overall survival was calculated by the Kaplan-Meier method. Thirty-two patients excluded by F-FDG PET/CT and/or ceCT before tentative LT for NCLM were identified. F-FDG PET/CT from 20 of the 32 excluded patients revealed extrahepatic disease. Eight of the other 12 patients had a negative F-FDG PET/CT finding but were excluded by ceCT. Ten patients were excluded by F-FDG PET/CT only. Four patients were excluded owing to detected malignancy from frozen sections at the start of the intended transplant operation. Tumor-to-background ratio of the liver metastases was significantly higher in patients where F-FDG PET/CT detected extrahepatic disease (P=0.03). The median (range) survival after exclusion was 16 (0-52) months. The ability of F-FDG PET/CT to detect extrahepatic disease before LT for NCLM is vital to establish LT as a treatment option.

  19. Fire and scald burn risks in urban communities: who is at risk and what do they believe about home safety?

    PubMed

    Parker, E M; Gielen, A C; McDonald, E M; Shields, W C; Trump, A R; Koon, K M; Jones, V

    2013-08-01

    While largely preventable, fire and hot water-related injuries are common in the United States. Measures recommended to reduce these injuries are smoke alarms (SAs) and lowered hot water temperatures. This study aims to: (i) describe the prevalence of working SAs and safe water temperatures among low-income, urban communities and (ii) explore the relationship between these behaviors and individuals' knowledge and beliefs about them. In this cross-sectional study, the Health Belief Model was used as a guide for understanding the safety behaviors. A total of 603 households had their SAs and hot tap water temperatures tested and were surveyed about their knowledge and beliefs related to these safety behaviors. We found that 40% of households had working SAs on every level and 57% had safe hot water temperatures. Perceived severity and self-efficacy were significantly associated with SA coverage, whereas perceived susceptibility and beliefs about benefits were significantly associated with safe hot water temperatures. This study demonstrates the need to increase the number of homes with working SAs and safe hot water temperatures. Messages focused on a safe home environment could communicate the ease and harm reduction features of SAs and benefits and risk reduction features of safe hot water temperatures.

  20. Fire and scald burn risks in urban communities: who is at risk and what do they believe about home safety?

    PubMed Central

    Parker, E. M.; Gielen, A. C.; McDonald, E. M.; Shields, W. C.; Trump, A. R.; Koon, K. M.; Jones, V.

    2013-01-01

    While largely preventable, fire and hot water-related injuries are common in the United States. Measures recommended to reduce these injuries are smoke alarms (SAs) and lowered hot water temperatures. This study aims to: (i) describe the prevalence of working SAs and safe water temperatures among low-income, urban communities and (ii) explore the relationship between these behaviors and individuals’ knowledge and beliefs about them. In this cross-sectional study, the Health Belief Model was used as a guide for understanding the safety behaviors. A total of 603 households had their SAs and hot tap water temperatures tested and were surveyed about their knowledge and beliefs related to these safety behaviors. We found that 40% of households had working SAs on every level and 57% had safe hot water temperatures. Perceived severity and self-efficacy were significantly associated with SA coverage, whereas perceived susceptibility and beliefs about benefits were significantly associated with safe hot water temperatures. This study demonstrates the need to increase the number of homes with working SAs and safe hot water temperatures. Messages focused on a safe home environment could communicate the ease and harm reduction features of SAs and benefits and risk reduction features of safe hot water temperatures. PMID:23487557

Top