Ben Younes, Lassad; Nakajima, Yoshikazu; Saito, Toki
2014-03-01
Femur segmentation is well established and widely used in computer-assisted orthopedic surgery. However, most of the robust segmentation methods such as statistical shape models (SSM) require human intervention to provide an initial position for the SSM. In this paper, we propose to overcome this problem and provide a fully automatic femur segmentation method for CT images based on primitive shape recognition and SSM. Femur segmentation in CT scans was performed using primitive shape recognition based on a robust algorithm such as the Hough transform and RANdom SAmple Consensus. The proposed method is divided into 3 steps: (1) detection of the femoral head as sphere and the femoral shaft as cylinder in the SSM and the CT images, (2) rigid registration between primitives of SSM and CT image to initialize the SSM into the CT image, and (3) fitting of the SSM to the CT image edge using an affine transformation followed by a nonlinear fitting. The automated method provided good results even with a high number of outliers. The difference of segmentation error between the proposed automatic initialization method and a manual initialization method is less than 1 mm. The proposed method detects primitive shape position to initialize the SSM into the target image. Based on primitive shapes, this method overcomes the problem of inter-patient variability. Moreover, the results demonstrate that our method of primitive shape recognition can be used for 3D SSM initialization to achieve fully automatic segmentation of the femur.
Effect of {sup 18}F-FDG PET/CT Imaging in Patients With Clinical Stage II and III Breast Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Groheux, David; Moretti, Jean-Luc; EAD Imagerie Moleculaire Diagnostique et Ciblage Therapeutique, IUH, University of Paris VII, Paris
2008-07-01
Purpose: To investigate the potential effect of using {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) in the initial assessment of patients with clinical Stage II or III breast cancer. Methods and Materials: During 14 consecutive months, 39 patients (40 tumors) who presented with Stage II or III breast cancer on the basis of a routine extension assessment were prospectively included in this study. PET/CT was performed in addition to the initial assessment. Results: In 3 cases, PET/CT showed extra-axillary lymph node involvement that had not been demonstrated with conventional techniques. Two of these patients had hypermetabolic lymph nodes in themore » subpectoral and infraclavicular regions, and the third had a hypermetabolic internal mammary node. PET/CT showed distant uptake in 4 women. Of these 4 women, 1 had pleural involvement and 3 had bone metastasis. Overall, of the 39 women, the PET/CT results modified the initial stage in 7 (18%). The modified staging altered the treatment plan for 5 patients (13%). It led to radiotherapy in 4 patients (bone metastasis, pleural lesion, subpectoral lymph nodes, and internal mammary nodes) and excision of, and radiotherapy to, the infraclavicular lymph nodes in 1 patient. Conclusions: PET/CT can provide information on extra-axillary lymph node involvement and can uncover occult distant metastases in a significant percentage of patients. Therefore, initial PET/CT could enable better treatment planning for patients with Stage II and III breast cancer.« less
The impact of diagnostic imaging wait times on the prognosis of lung cancer.
Byrne, Suzanne C; Barrett, Brendan; Bhatia, Rick
2015-02-01
This study was performed to determine whether gaps in patient flow from initial lung imaging to computed tomography (CT) guided lung biopsy in patients with non-small cell lung cancer (NSCLC) was associated with a change in tumour size, stage, and thus prognosis. All patients who had a CT-guided lung biopsy in 2009 (phase I) and in 2011 (phase II) with a pathologic diagnosis of primary lung cancer (NSCLC) at Eastern Health, Newfoundland, were identified. Dates of initial abnormal imaging, confirmatory CT (if performed), and CT-guided biopsy were recorded, along with tumour size and resulting T stage at each time point. In 2010, wait times for diagnostic imaging at Eastern Health were reduced. The stage and prognosis of NSCLC in 2009 was compared with 2011. In phase 1, there was a statistically significant increase in tumour size (mean difference, 0.67 cm; P < .0001) and stage (P < .0001) from initial image to biopsy. There was a moderate correlation between the time (in days) between the images and change in size (r = 0.33, P = .008) or stage (r = 0.26, P = .036). In phase II, the median wait time from initial imaging to confirmatory CT was reduced to 7.5 days (from 19 days). At this reduced wait time, there was no statistically significant increase in tumour size (mean difference, 0.02; P > .05) or stage (P > .05) from initial imaging to confirmatory CT. Delays in patient flow through diagnostic imaging resulted in an increase in tumour size and stage, with a negative impact on prognosis of NSCLC. This information contributed to the hiring of additional CT technologists and extended CT hours to decrease the wait time for diagnostic imaging. With reduced wait times, the prognosis of NSCLC was not adversely impacted as patients navigated through diagnostic imaging. Copyright © 2015 Canadian Association of Radiologists. All rights reserved.
Results of initial low-dose computed tomographic screening for lung cancer.
Church, Timothy R; Black, William C; Aberle, Denise R; Berg, Christine D; Clingan, Kathy L; Duan, Fenghai; Fagerstrom, Richard M; Gareen, Ilana F; Gierada, David S; Jones, Gordon C; Mahon, Irene; Marcus, Pamela M; Sicks, JoRean D; Jain, Amanda; Baum, Sarah
2013-05-23
Lung cancer is the largest contributor to mortality from cancer. The National Lung Screening Trial (NLST) showed that screening with low-dose helical computed tomography (CT) rather than with chest radiography reduced mortality from lung cancer. We describe the screening, diagnosis, and limited treatment results from the initial round of screening in the NLST to inform and improve lung-cancer-screening programs. At 33 U.S. centers, from August 2002 through April 2004, we enrolled asymptomatic participants, 55 to 74 years of age, with a history of at least 30 pack-years of smoking. The participants were randomly assigned to undergo annual screening, with the use of either low-dose CT or chest radiography, for 3 years. Nodules or other suspicious findings were classified as positive results. This article reports findings from the initial screening examination. A total of 53,439 eligible participants were randomly assigned to a study group (26,715 to low-dose CT and 26,724 to chest radiography); 26,309 participants (98.5%) and 26,035 (97.4%), respectively, underwent screening. A total of 7191 participants (27.3%) in the low-dose CT group and 2387 (9.2%) in the radiography group had a positive screening result; in the respective groups, 6369 participants (90.4%) and 2176 (92.7%) had at least one follow-up diagnostic procedure, including imaging in 5717 (81.1%) and 2010 (85.6%) and surgery in 297 (4.2%) and 121 (5.2%). Lung cancer was diagnosed in 292 participants (1.1%) in the low-dose CT group versus 190 (0.7%) in the radiography group (stage 1 in 158 vs. 70 participants and stage IIB to IV in 120 vs. 112). Sensitivity and specificity were 93.8% and 73.4% for low-dose CT and 73.5% and 91.3% for chest radiography, respectively. The NLST initial screening results are consistent with the existing literature on screening by means of low-dose CT and chest radiography, suggesting that a reduction in mortality from lung cancer is achievable at U.S. screening centers that have staff experienced in chest CT. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Bin; Lyu, Qingwen; Ma, Jianhua
2016-04-15
Purpose: In computed tomography perfusion (CTP) imaging, an initial phase CT acquired with a high-dose protocol can be used to improve the image quality of later phase CT acquired with a low-dose protocol. For dynamic regions, signals in the later low-dose CT may not be completely recovered if the initial CT heavily regularizes the iterative reconstruction process. The authors propose a hybrid nonlocal means (hNLM) regularization model for iterative reconstruction of low-dose CTP to overcome the limitation of the conventional prior-image induced penalty. Methods: The hybrid penalty was constructed by combining the NLM of the initial phase high-dose CT inmore » the stationary region and later phase low-dose CT in the dynamic region. The stationary and dynamic regions were determined by the similarity between the initial high-dose scan and later low-dose scan. The similarity was defined as a Gaussian kernel-based distance between the patch-window of the same pixel in the two scans, and its measurement was then used to weigh the influence of the initial high-dose CT. For regions with high similarity (e.g., stationary region), initial high-dose CT played a dominant role for regularizing the solution. For regions with low similarity (e.g., dynamic region), the regularization relied on a low-dose scan itself. This new hNLM penalty was incorporated into the penalized weighted least-squares (PWLS) for CTP reconstruction. Digital and physical phantom studies were performed to evaluate the PWLS-hNLM algorithm. Results: Both phantom studies showed that the PWLS-hNLM algorithm is superior to the conventional prior-image induced penalty term without considering the signal changes within the dynamic region. In the dynamic region of the Catphan phantom, the reconstruction error measured by root mean square error was reduced by 42.9% in PWLS-hNLM reconstructed image. Conclusions: The PWLS-hNLM algorithm can effectively use the initial high-dose CT to reconstruct low-dose CTP in the stationary region while reducing its influence in the dynamic region.« less
Pinilla, I; Gómez-León, N; Del Campo-Del Val, L; Hernandez-Maraver, D; Rodríguez-Vigil, B; Jover-Díaz, R; Coya, J
2011-10-01
The aim of this paper was to compare the accuracy of contrast-enhanced computed tomography (CT), positron emission tomography (PET), unenhanced low-dose PET/CT (LD-PET/CT) and full-dose enhanced PET/CT (FD-PET/CT) for the initial staging of lymphoma. One hundred and one lymphoma patients were examined by [18F]FDG-PET/CT including unenhanced low-dose CT and enhanced full-dose CT. Each modality of PET/CT was evaluated by a nuclear medicine physician and a radiologist unaware of the other modality, while the CT and PET images were interpreted separately by another independent radiologist and nuclear medicine physician respectively. The nodal and extranodal lesions detected by each technique were compared with a reference standard. For nodal assessment, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative LR (LR-) of LD-PET/CT were 97%, 96%, 98%, 95%, 26 and 0.02 respectively, and those of FD-PET/CT were 97%, 97%, 98%, 95%, 36 and 0.02. These results were significantly better than those of PET (sensitivity 82%, specificity 81%, PPV 88%, NPV 72%, LR+ 4.3, LR- 0.21). Likewise, both PET/CT displayed a higher sensitivity, NPV and LR- than CT (91%, 84%, 0.1 respectively). For organ evaluation, both modalities of PET/CT also had significantly better sensitivity and NPV than that of PET (LD-PET/CT: sensitivity 92%, NPV 90%; FD-PET/CT sensitivity 94%, NPV 92%; PET: sensitivity 70%, NPV 69%). The sensitivity, specificity, PPV and NPV for bone marrow involvement were 29%, 84%, 45% and 72% respectively for PET, and 29%, 90%, 56%, and 74% for both, LD-PET/CT, and FD-PET/CT. No significant differences were found between LD-PET/CT and FD-PET/CT, but FD-PET/CT detected important incidental findings in 5.9% of patients. PET/CT is an accurate technique for the initial staging of lymphomas without significant differences between LD-PET/CT and FD-PET/CT. FD-PET/CT detects relevant incidental findings that are missed on LD-PET/CT.
Menditto, Vincenzo G; Lucci, Moira; Polonara, Stefano; Pomponio, Giovanni; Gabrielli, Armando
2012-06-01
Patients receiving warfarin who experience minor head injury are at risk of intracranial hemorrhage, and optimal management after a single head computed tomography (CT) scan is unclear. We evaluate a protocol of 24-hour observation followed by a second head CT scan. In this prospective case series, we enrolled consecutive patients receiving warfarin and showing no intracranial lesions on a first CT scan after minor head injury treated at a Level II trauma center. We implemented a structured clinical pathway, including 24-hour observation and a CT scan performed before discharge. We then evaluated the frequency of death, admission, neurosurgery, and delayed intracranial hemorrhage. We enrolled and observed 97 consecutive patients. Ten refused the second CT scan and were well during 30-day follow-up. Repeated CT scanning in the remaining 87 patients revealed a new hemorrhage lesion in 5 (6%), with 3 subsequently hospitalized and 1 receiving craniotomy. Two patients discharged after completing the study protocol with 2 negative CT scan results were admitted 2 and 8 days later with symptomatic subdural hematomas; neither received surgery. Two of the 5 patients with delayed bleeding at 24 hours had an initial international normalized ratio greater than 3.0, as did both patients with delayed bleeding beyond 24 hours. The relative risk of delayed hemorrhage with an initial international normalized ratio greater than 3.0 was 14 (95% confidence interval 4 to 49). For patients receiving warfarin who experience minor head injury and have a negative initial head CT scan result, a protocol of 24-hour observation followed by a second CT scan will identify most occurrences of delayed bleeding. An initial international normalized ratio greater than 3 suggests higher risk. Copyright © 2011 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Dna2 initiates resection at clean DNA double-strand breaks
Paudyal, Sharad C.; Li, Shan; Yan, Hong; Hunter, Tony
2017-01-01
Abstract Nucleolytic resection of DNA double-strand breaks (DSBs) is essential for both checkpoint activation and homology-mediated repair; however, the precise mechanism of resection, especially the initiation step, remains incompletely understood. Resection of blocked ends with protein or chemical adducts is believed to be initiated by the MRN complex in conjunction with CtIP through internal cleavage of the 5′ strand DNA. However, it is not clear whether resection of clean DSBs with free ends is also initiated by the same mechanism. Using the Xenopus nuclear extract system, here we show that the Dna2 nuclease directly initiates the resection of clean DSBs by cleaving the 5′ strand DNA ∼10–20 nucleotides away from the ends. In the absence of Dna2, MRN together with CtIP mediate an alternative resection initiation pathway where the nuclease activity of MRN apparently directly cleaves the 5′ strand DNA at more distal sites. MRN also facilitates resection initiation by promoting the recruitment of Dna2 and CtIP to the DNA substrate. The ssDNA-binding protein RPA promotes both Dna2- and CtIP–MRN-dependent resection initiation, but a RPA mutant can distinguish between these pathways. Our results strongly suggest that resection of blocked and clean DSBs is initiated via distinct mechanisms. PMID:28981724
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karlsson, Per, E-mail: per.karlsson@oncology.gu.se; Cole, Bernard F.; Price, Karen N.
Purpose: To update the previous report from 2 randomized clinical trials, now with a median follow-up of 16 years, to analyze the effect of radiation therapy timing on local failure and disease-free survival. Patients and Methods: From July 1986 to April 1993, International Breast Cancer Study Group trial VI randomly assigned 1475 pre-/perimenopausal women with node-positive breast cancer to receive 3 or 6 cycles of initial chemotherapy (CT). International Breast Cancer Study Group trial VII randomly assigned 1212 postmenopausal women with node-positive breast cancer to receive tamoxifen for 5 years, or tamoxifen for 5 years with 3 early cycles of initial CT. Formore » patients who received breast-conserving surgery (BCS), radiation therapy (RT) was delayed until initial CT was completed; 4 or 7 months after BCS for trial VI and 2 or 4 months for trial VII. We compared RT timing groups among 433 patients on trial VI and 285 patients on trial VII who received BCS plus RT. Endpoints were local failure, regional/distant failure, and disease-free survival (DFS). Results: Among pre-/perimenopausal patients there were no significant differences in disease-related outcomes. The 15-year DFS was 48.2% in the group allocated 3 months initial CT and 44.9% in the group allocated 6 months initial CT (hazard ratio [HR] 1.12; 95% confidence interval [CI] 0.87-1.45). Among postmenopausal patients, the 15-year DFS was 46.1% in the no-initial-CT group and 43.3% in the group allocated 3 months initial CT (HR 1.11; 95% CI 0.82-1.51). Corresponding HRs for local failures were 0.94 (95% CI 0.61-1.46) in trial VI and 1.51 (95% CI 0.77-2.97) in trial VII. For regional/distant failures, the respective HRs were 1.15 (95% CI 0.80-1.63) and 1.08 (95% CI 0.69-1.68). Conclusions: This study confirms that, after more than 15 years of follow-up, it is reasonable to delay radiation therapy until after the completion of standard CT.« less
Generation of synthetic CT data using patient specific daily MR image data and image registration
NASA Astrophysics Data System (ADS)
Melanie Kraus, Kim; Jäkel, Oliver; Niebuhr, Nina I.; Pfaffenberger, Asja
2017-02-01
To fully exploit the advantages of magnetic resonance imaging (MRI) for radiotherapy (RT) treatment planning, a method is required to overcome the problem of lacking electron density information. We aim to establish and evaluate a new method for computed tomography (CT) data generation based on MRI and image registration. The thereby generated CT data is used for dose accumulation. We developed a process flow based on an initial pair of rigidly co-registered CT and T2-weighted MR image representing the same anatomical situation. Deformable image registration using anatomical landmarks is performed between the initial MRI data and daily MR images. The resulting transformation is applied to the initial CT, thus fractional CT data is generated. Furthermore, the dose for a photon intensity modulated RT (IMRT) or intensity modulated proton therapy (IMPT) plan is calculated on the generated fractional CT and accumulated on the initial CT via inverse transformation. The method is evaluated by the use of phantom CT and MRI data. Quantitative validation is performed by evaluation of the mean absolute error (MAE) between the measured and the generated CT. The effect on dose accumulation is examined by means of dose-volume parameters. One patient case is presented to demonstrate the applicability of the method introduced here. Overall, CT data derivation lead to MAEs with a median of 37.0 HU ranging from 29.9 to 66.6 HU for all investigated tissues. The accuracy of image registration showed to be limited in the case of unexpected air cavities and at tissue boundaries. The comparisons of dose distributions based on measured and generated CT data agree well with the published literature. Differences in dose volume parameters kept within 1.6% and 3.2% for photon and proton RT, respectively. The method presented here is particularly suited for application in adaptive RT in current clinical routine, since only minor additional technical equipment is required.
NASA Technical Reports Server (NTRS)
Czabaj, Michael W.; Ratcliffe, James
2012-01-01
The intralaminar and interlaminar mode-I fracture-toughness of a unidirectional IM7/8552 graphite/epoxy composite were measured using compact tension (CT) and double cantilever beam (DCB) test specimens, respectively. Two starter crack geometries were considered for both the CT and DCB specimen configurations. In the first case, starter cracks were produced by 12.5 micron thick, Teflon film inserts. In the second case, considerably sharper starter cracks were produced by fatigue precracking. For each specimen configuration, use of the Teflon film starter cracks resulted in initially unstable crack growth and artificially high initiation fracture-toughness values. Conversely, specimens with fatigue precracks exhibited stable growth onset and lower initiation fracture toughness. For CT and DCB specimens with fatigue precracks, the intralaminar and interlaminar initiation fracture toughnesses were approximately equal. However, during propagation, the CT specimens exhibited more extensive fiber bridging, and rapidly increasing R-curve behavior as compared to the DCB specimens. Observations of initiation and propagation of intralaminar and interlaminar fracture, and the measurements of fracture toughness, were supported by fractographic analysis using scanning electron microscopy.
SU-E-J-267: Change in Mean CT Intensity of Lung Tumors During Radiation Treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahon, R; Tennyson, N; Weiss, E
2015-06-15
Purpose: To evaluate CT intensity change of lung tumors during radiation therapy. Methods: Repeated 4D CT images were acquired on a CT simulator during the course of therapy for 27 lung cancer patients on IRB approved protocols. All subjects received definitive radiation treatment ± chemotherapy. CT scans were completed prior to treatment, and 2–7 times during the treatment course. Primary tumor was delineated by an experienced Radiation Oncologist. Contours were thresholded between −100 HU and 200 HU to remove airways and bone. Correlations between the change in the mean tumor intensity and initial tumor intensity, SUVmax, and tumor volume changemore » rate were investigated. Reproducibility was assessed by evaluating the variation in mean intensity over all phases in 4DCT, for a subgroup of 19 subjects. Results: Reproducibility of tumor intensity between phases as characterized by the root mean square of standard deviation across 19 subjects was 1.8 HU. Subjects had a mean initial tumor intensity of 16.5 ± 11.6 HU and an overall reduction in HU by 10.3 ± 8.5 HU. Evaluation of the changes in tumor intensity during treatment showed a decrease of 0.3 ± 0.3 HU/day for all subjects, except three. No significant correlation was found between change in HU/day and initial HU intensity (p=0.53), initial PET SUVmax (p=0.69), or initial tumor volume (p=0.70). The rate of tumor volume change was weakly correlated (R{sup 2}=0.05) with HU change (p=0.01). Conclusion: Most lung cancer subjects showed a marked trend of decreasing mean tumor CT intensity throughout radiotherapy, including early in the treatment course. Change in HU/day is not correlated with other potential early predictors for response, such as SUV and tumor volume change. This Result supports future studies to evaluate change in tumor intensity on CT as an early predictor of response.« less
Markel, Troy A; Kumar, Rajiv; Koontz, Nicholas A; Scherer, L R; Applegate, Kimberly E
2009-07-01
There is a growing concern that computed tomography (CT) is being unnecessarily overused for the evaluation of pediatric patients. The purpose of this study was to analyze the trends and utility of chest CT use compared with chest X-ray (CXR) for the evaluation of children with blunt chest trauma. A 4-year retrospective review was performed for pediatric patients who underwent chest CT within 24 hours of sustaining blunt trauma at a Level-I trauma center. Trends in the use of CT and CXR were documented, and results of radiology reports were analyzed and compared with clinical outcomes. Three hundred thirty-three children, mean age 11 years, had chest CTs, increasing from 5.5% in 2001-2002 to 10.5% in 2004-2005 (p < 0.001). Conversely, in those children who underwent chest CT, the rate of initial CXR use decreased from 84% to 56% during the same period (p < 0.001). Twenty percent of chest CTs had significant positive findings. Six patients underwent emergency surgery for cardiac or arterial injuries, and all demonstrated abnormal findings on CXR or CT scout imaging. When compared with the CT, only 5% of initial CXRs falsely reported normal findings that may have altered management. CT use in children has increased rapidly for the initial evaluation of chest trauma, whereas CXR use has decreased. Despite this trend, CXR remains an acceptable screening tool to analyze which patients may require CT evaluation. A multidisciplinary approach is warranted to develop guidelines that standardize the use of CT and thereby decreases unnecessary radiation exposure to pediatric patients.
Edge-oriented dual-dictionary guided enrichment (EDGE) for MRI-CT image reconstruction.
Li, Liang; Wang, Bigong; Wang, Ge
2016-01-01
In this paper, we formulate the joint/simultaneous X-ray CT and MRI image reconstruction. In particular, a novel algorithm is proposed for MRI image reconstruction from highly under-sampled MRI data and CT images. It consists of two steps. First, a training dataset is generated from a series of well-registered MRI and CT images on the same patients. Then, an initial MRI image of a patient can be reconstructed via edge-oriented dual-dictionary guided enrichment (EDGE) based on the training dataset and a CT image of the patient. Second, an MRI image is reconstructed using the dictionary learning (DL) algorithm from highly under-sampled k-space data and the initial MRI image. Our algorithm can establish a one-to-one correspondence between the two imaging modalities, and obtain a good initial MRI estimation. Both noise-free and noisy simulation studies were performed to evaluate and validate the proposed algorithm. The results with different under-sampling factors show that the proposed algorithm performed significantly better than those reconstructed using the DL algorithm from MRI data alone.
Woodward, Elizabeth; Hackmann, Ann; Wild, Jennifer; Grey, Nick; Clark, David M; Ehlers, Anke
2017-10-01
The effectiveness and mechanisms of psychotherapies for posttraumatic stress disorder (PTSD) in treating sleep problems is of interest. This study compared the effects of a trauma-focused and a non-trauma-focused psychotherapy on sleep, to investigate whether 1) sleep improves with psychotherapy for PTSD; 2) the degree of sleep improvement depends on whether the intervention is trauma or nontrauma-focused; 3) the memory-updating procedure in cognitive therapy for PTSD (CT-PTSD) is associated with sleep improvements; 4) initial sleep duration affects PTSD treatment outcome; and 5) which symptom changes are associated with sleep duration improvements. Self-reported sleep was assessed during a randomized controlled trial (Ehlers et al., 2014) comparing CT-PTSD (delivered weekly or intensively over 7-days) with emotion-focused supportive therapy, and a waitlist. Sleep duration was reported daily in sleep diaries during intensive CT-PTSD. CT-PTSD led to greater increases in sleep duration (55.2 min) and reductions in insomnia symptoms and nightmares than supportive therapy and the waitlist. In intensive CT-PTSD, sleep duration improved within 7 days, and sleep diaries indicated a 40-min sleep duration increase after updating trauma memories. Initial sleep duration was not related to CT-PTSD treatment outcome when initial PTSD symptom severity was controlled. The results suggest that trauma-focused psychotherapy for PTSD is more effective than nontrauma-focused therapy in improving self-reported sleep, and that CT-PTSD can still be effective in the presence of reduced sleep duration. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Perfusion CT helps decision making for thrombolysis when there is no clear time of onset
Hellier, K D; Hampton, J L; Guadagno, J V; Higgins, N P; Antoun, N M; Day, D J; Gillard, J H; Warburton, E A; Baron, J‐C
2006-01-01
Current guidelines on thrombolysis post stroke with recombinant tissue plasminogen activator (rt‐PA) exclude its use where time of onset is unknown, thus denying some patients potentially beneficial treatment. Contrast enhanced perfusion computed tomography (pCT) imaging can be used together with plain CT and information on clinical deficits to decide whether or not thrombolysis should be initiated even though the exact time of stroke onset is unknown. Based on the results of pCT and CT, rt‐PA was administered to two patients with unknown time of stroke onset; one of the patients also underwent suction thrombectomy. Results in both cases were excellent. PMID:16484659
Cognitive training in Alzheimer's disease: a controlled randomized study.
Giovagnoli, A R; Manfredi, V; Parente, A; Schifano, L; Oliveri, S; Avanzini, G
2017-08-01
This controlled randomized single-blind study evaluated the effects of cognitive training (CT), compared to active music therapy (AMT) and neuroeducation (NE), on initiative in patients with mild to moderate Alzheimer's disease (AD). Secondarily, we explored the effects of CT on episodic memory, mood, and social relationships. Thirty-nine AD patients were randomly assigned to CT, AMT, or NE. Each treatment lasted 3 months. Before, at the end, and 3 months after treatment, neuropsychological tests and self-rated scales assessed initiative, episodic memory, depression, anxiety, and social relationships. At the end of the CT, initiative significantly improved, whereas, at the end of AMT and NE, it was unchanged. Episodic memory showed no changes at the end of CT or AMT and a worsening after NE. The rates of the patients with clinically significant improvement of initiative were greater after CT (about 62%) than after AMT (about 8%) or NE (none). At the 3-month follow-up, initiative and episodic memory declined in all patients. Mood and social relationships improved in the three groups, with greater changes after AMT or NE. In patients with mild to moderate AD, CT can improve initiative and stabilize memory, while the non-cognitive treatments can ameliorate the psychosocial aspects. The combining of CT and non-cognitive treatments may have useful clinical implications.
Automatic lung nodule matching for the follow-up in temporal chest CT scans
NASA Astrophysics Data System (ADS)
Hong, Helen; Lee, Jeongjin; Shin, Yeong Gil
2006-03-01
We propose a fast and robust registration method for matching lung nodules of temporal chest CT scans. Our method is composed of four stages. First, the lungs are extracted from chest CT scans by the automatic segmentation method. Second, the gross translational mismatch is corrected by the optimal cube registration. This initial registration does not require extracting any anatomical landmarks. Third, initial alignment is step by step refined by the iterative surface registration. To evaluate the distance measure between surface boundary points, a 3D distance map is generated by the narrow-band distance propagation, which drives fast and robust convergence to the optimal location. Fourth, nodule correspondences are established by the pairs with the smallest Euclidean distances. The results of pulmonary nodule alignment of twenty patients are reported on a per-center-of mass point basis using the average Euclidean distance (AED) error between corresponding nodules of initial and follow-up scans. The average AED error of twenty patients is significantly reduced to 4.7mm from 30.0mm by our registration. Experimental results show that our registration method aligns the lung nodules much faster than the conventional ones using a distance measure. Accurate and fast result of our method would be more useful for the radiologist's evaluation of pulmonary nodules on chest CT scans.
Lattanzi, J P; Fein, D A; McNeeley, S W; Shaer, A H; Movsas, B; Hanks, G E
1997-01-01
We describe our initial experience with the AcQSim (Picker International, St. David, PA) computed tomography-magnetic resonance imaging (CT-MRI) fusion software in eight patients with intracranial lesions. MRI data are electronically integrated into the CT-based treatment planning system. Since MRI is superior to CT in identifying intracranial abnormalities, we evaluated the precision and feasibility of this new localization method. Patients initially underwent CT simulation from C2 to the most superior portion of the scalp. T2 and post-contrast T1-weighted MRI of this area was then performed. Patient positioning was duplicated utilizing a head cup and bridge of nose to forehead angle measurements. First, a gross tumor volume (GTV) was identified utilizing the CT (CT/GTV). The CT and MRI scans were subsequently fused utilizing a point pair matching method and a second GTV (CT-MRI/GTV) was contoured with the aid of both studies. The fusion process was uncomplicated and completed in a timely manner. Volumetric analysis revealed the CT-MRI/GTV to be larger than the CT/GTV in all eight cases. The mean CT-MRI/GTV was 28.7 cm3 compared to 16.7 cm3 by CT alone. This translated into a 72% increase in the radiographic tumor volume by CT-MRI. A simulated dose-volume histogram in two patients revealed that marginal portions of the lesion, as identified by CT and MRI, were not included in the high dose treatment volume as contoured with the use of CT alone. Our initial experience with the fusion software demonstrated an improvement in tumor localization with this technique. Based on these patients the use of CT alone for treatment planning purposes in central nervous system (CNS) lesions is inadequate and would result in an unacceptable rate of marginal misses. The importation of MRI data into three-dimensional treatment planning is therefore crucial to accurate tumor localization. The fusion process simplifies and improves precision of this task.
Solnes, Lilja B; Jones, Krystyna M; Rowe, Steven P; Pattanayak, Puskar; Nalluri, Abhinav; Venkatesan, Arun; Probasco, John C; Javadi, Mehrbod S
2017-08-01
Diagnosis of autoimmune encephalitis presents some challenges in the clinical setting because of varied clinical presentations and delay in obtaining antibody panel results. We examined the role of neuroimaging in the setting of autoimmune encephalitides, comparing the utility of 18 F-FDG PET/CT versus conventional brain imaging with MRI. Methods: A retrospective study was performed assessing the positivity rate of MRI versus 18 F-FDG PET/CT during the initial workup of 23 patients proven to have antibody-positive autoimmune encephalitis. 18 F-FDG PET/CT studies were analyzed both qualitatively and semiquantitatively. Areas of cortical lobar hypo (hyper)-metabolism in the cerebrum that were 2 SDx from the mean were recorded as abnormal. Results: On visual inspection, all patients were identified as having an abnormal pattern of 18 F-FDG uptake. In semiquantitative analysis, at least 1 region of interest with metabolic change was identified in 22 of 23 (95.6%) patients using a discriminating z score of 2. Overall, 18 F-FDG PET/CT was more often abnormal during the diagnostic period than MRI (10/23, 43% of patients). The predominant finding on brain 18 F-FDG PET/CT imaging was lobar hypometabolism, being observed in 21 of 23 (91.3%) patients. Hypometabolism was most commonly observed in the parietal lobe followed by the occipital lobe. An entire subset of antibody-positive patients, anti- N -methyl-d-aspartate receptor (5 patients), had normal MRI results and abnormal 18 F-FDG PET/CT findings whereas the other subsets demonstrated a greater heterogeneity. Conclusion: Brain 18 F-FDG PET/CT may play a significant role in the initial evaluation of patients with clinically suspected antibody-mediated autoimmune encephalitis. Given that it is more often abnormal when compared with MRI in the acute setting, this molecular imaging technique may be better positioned as an early biomarker of disease so that treatment may be initiated earlier, resulting in improved patient outcomes. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Kamgar-Parsi, Kian; Hong, Liu; Naito, Akira; Brooks, Charles L; Ramamoorthy, Ayyalusamy
2017-09-08
The role of the peptide hormone calcitonin in skeletal protection has led to its use as a therapeutic for osteoporosis. However, calcitonin aggregation into amyloid fibrils limits its therapeutic efficacy, necessitating a modification of calcitonin's aggregation kinetics. Here, we report a direct relationship between human calcitonin (hCT) concentration and aggregation lag time. This kinetic trend was contrary to the conventional understanding of amyloid aggregation and persisted over a range of aggregation conditions, as confirmed by thioflavin-T kinetics assays, CD spectroscopy, and transmission EM. Dynamic light scattering, 1 H NMR experiments, and seeded thioflavin-T assay results indicated that differences in initial peptide species contribute to this trend more than variations in the primary nucleus formation rate. On the basis of kinetics modeling results, we propose a mechanism whereby a structural conversion of hCT monomers is needed before incorporation into the fibril. Our kinetic mechanism recapitulates the experimentally observed relationship between peptide concentration and lag time and represents a novel mechanism in amyloid aggregation. Interestingly, hCT at low pH and salmon calcitonin (sCT) exhibited the canonical inverse relationship between concentration and lag time. Comparative studies of hCT and sCT with molecular dynamics simulations and CD indicated an increased α-helical structure in sCT and low-pH hCT monomers compared with neutral-pH hCT, suggesting that α-helical monomers represent a growth-competent species, whereas unstructured random coil monomers represent a growth-incompetent species. Our finding that initial monomer concentration is positively correlated with lag time in hCT aggregation could help inform future efforts for improving therapeutic applications of CT. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, J; Huang, J; Szczykutowicz, T
2016-06-15
Purpose: To perform an initial evaluation of a novel split-filter dual-energy CT (DECT) system with the goal of understanding the clinical utility and limitations of the system for radiation therapy. Methods: Several phantoms were imaged using the split-filter DECT technique on the Siemens Edge CT scanner using a range of clinically-relevant doses. The optimum-contrast reconstruction, the mixed reconstruction, and the monoenergetic reconstructions (ranging from 40 keV to 190 keV) were evaluated. Each image was analyzed for CT number accuracy, uniformity, noise, low-contrast visibility (LCV), spatial resolution and geometric distortion. For comparison purposes, all parameters were evaluated on 120 kVp single-energymore » CT (SECT) scans used for treatment planning, as well as, a sequential-scan DECT technique for corresponding doses. Results: For all DECT reconstructions no observable geometric distortion was found. Both the optimal-contrast and mixed images demonstrated slight improvements in LCV and noise when compared to the SECT, and slight reductions in CT number accuracy and spatial resolution. The CT numbers trended as expected for the monoenergetic reconstructions, with CT number accuracy within 50 HU for materials of density <2 g/cm3. Spatial resolution increased with energy, and for monoenergetic reconstructions >70 keV the spatial resolution exceeded that of the SECT. The noise in the monoenergetic reconstructions increased with decreasing energy. Thus, the image uniformity, signal-to-noise ratio and LCV were diminished at lower energies (70 keV). Applying iterative reconstruction techniques to the low-energy images reduced noise and improved LCV. The signal-to-noise ratio was stable for energies >100 keV. Conclusion: The initial commissioning of the novel split-filter DECT technology demonstrated favorable results for clinical implementation. The mixed reconstruction showed potential as a replacement for the treatment planning SECT. The image parameters for the monoenergetic reconstructions varied appropriately with energy. This work provides an initial understanding of the limitations and potential applications for monoenergetic imaging.« less
Choe, Junho; Oh, Nara; Park, Sungjin; Lee, Ye Kyung; Song, Ok-Kyu; Locker, Nicolas; Chi, Sung-Gil; Kim, Yoon Ki
2012-05-25
In the cytoplasm of mammalian cells, either cap-binding proteins 80 and 20 (CBP80/20) or eukaryotic translation initiation factor (eIF) 4E can direct the initiation of translation. Although the recruitment of ribosomes to mRNAs during eIF4E-dependent translation (ET) is well characterized, the molecular mechanism for CBP80/20-dependent translation (CT) remains obscure. Here, we show that CBP80/20-dependent translation initiation factor (CTIF), which has been shown to be preferentially involved in CT but not ET, specifically interacts with eIF3g, a component of the eIF3 complex involved in ribosome recruitment. By interacting with eIF3g, CTIF serves as an adaptor protein to bridge the CBP80/20 and the eIF3 complex, leading to efficient ribosome recruitment during CT. Accordingly, down-regulation of CTIF using a small interfering RNA causes a redistribution of CBP80 from polysome fractions to subpolysome fractions, without significant consequence to eIF4E distribution. In addition, down-regulation of eIF3g inhibits the efficiency of nonsense-mediated mRNA decay, which is tightly coupled to CT but not to ET. Moreover, the artificial tethering of CTIF to an intercistronic region of dicistronic mRNA results in translation of the downstream cistron in an eIF3-dependent manner. These findings support the idea that CT mechanistically differs from ET.
Real-time CT-video registration for continuous endoscopic guidance
NASA Astrophysics Data System (ADS)
Merritt, Scott A.; Rai, Lav; Higgins, William E.
2006-03-01
Previous research has shown that CT-image-based guidance could be useful for the bronchoscopic assessment of lung cancer. This research drew upon the registration of bronchoscopic video images to CT-based endoluminal renderings of the airway tree. The proposed methods either were restricted to discrete single-frame registration, which took several seconds to complete, or required non-real-time buffering and processing of video sequences. We have devised a fast 2D/3D image registration method that performs single-frame CT-Video registration in under 1/15th of a second. This allows the method to be used for real-time registration at full video frame rates without significantly altering the physician's behavior. The method achieves its speed through a gradient-based optimization method that allows most of the computation to be performed off-line. During live registration, the optimization iteratively steps toward the locally optimal viewpoint at which a CT-based endoluminal view is most similar to a current bronchoscopic video frame. After an initial registration to begin the process (generally done in the trachea for bronchoscopy), subsequent registrations are performed in real-time on each incoming video frame. As each new bronchoscopic video frame becomes available, the current optimization is initialized using the previous frame's optimization result, allowing continuous guidance to proceed without manual re-initialization. Tests were performed using both synthetic and pre-recorded bronchoscopic video. The results show that the method is robust to initialization errors, that registration accuracy is high, and that continuous registration can proceed on real-time video at >15 frames per sec. with minimal user-intervention.
Routine repeat head CT may not be necessary for patients with mild TBI
Rosen, Claire B; Luy, Diego D; Deane, Molly R; Scalea, Thomas M; Stein, Deborah M
2018-01-01
Background Routine repeat cranial CT (RHCT) is standard of care for CT-verified traumatic brain injury (TBI). Despite mixed evidence, those with mild TBI are subject to radiation and expense from serial CT scans. Thus, we investigated the necessity and utility of RHCT for patients with mild TBI. We hypothesized that repeat head CT in these patients would not alter patient care or outcomes. Methods We retrospectively studied patients suffering from mild TBI (Glasgow Coma Scale (GCS) score 13–15) and treated at the R Adams Cowley Shock Trauma Center from November 2014 through January 2015. The primary outcome was the need for surgical intervention. Outcomes were compared using paired Student’s t-test, and stratified by injury on initial CT, GCS change, demographics, and presenting vital signs (mean ± SD). Results Eighty-five patients met inclusion criteria with an average initial GCS score=14.6±0.57. Our center sees about 2800 patients with TBI per year, or about 230 per month. This includes patients with concussions. This sample represents about 30% of patients with TBI seen during the study period. Ten patients required operation (four based on initial CT and others for worsening GCS, headaches, large unresolving injury). There was progression of injury on repeat CT scan in only two patients that required operation, and this accompanied clinical deterioration. The mean brain Abbreviated Injury Scale (AIS) score was 4.8±0.3 for surgical patients on initial CT scan compared with 3.4±0.6 (P<0.001) for non-surgical patients. Initial CT subdural hematoma size was 1.1±0.6 cm for surgical patients compared with 0.49±0.3 cm (P=0.05) for non-surgical patients. There was no significant difference between intervention groups in terms of other intracranial injuries, demographics, vital signs, or change in GCS. Overall, 75 patients that did not require surgical intervention received RHCT. At $340 per CT, $51 000 was spent on unnecessary imaging ($367 000/year, extrapolated). Discussion In an environment of increased scrutiny on healthcare expenditures, it is necessary to question dogma and eliminate unnecessary cost. Our data questions the use of routine repeat head CT scans in every patient with anatomic TBI and suggests that clinically stable patients with small injury can simply be followed clinically. Level of evidence Level III. PMID:29766124
Kinetic analysis of Legionella inactivation using ozone in wastewater.
Li, Jun; Li, Kunquan; Zhou, Yan; Li, Xuebin; Tao, Tao
2017-02-01
Legionella inactivation using ozone was studied in wastewater using kinetic analysis and modeling. The experimental results indicate that the relationship between the ozone concentration, germ concentration, and chemical oxygen demand (COD) can be used to predict variations in germ and COD concentrations. The ozone reaction with COD and inactivation of Legionella occurred simultaneously, but the reaction with COD likely occurred at a higher rate than the inactivation, as COD is more easily oxidized by ozone than Legionella. Higher initial COD concentrations resulted in a lower inactivation rate and higher lnN/N 0 . Higher temperature led to a higher inactivation efficiency. The relationship of the initial O 3 concentration and Legionella inactivation rate was not linear, and thus, the Ct value required for a 99.99% reduction was not constant. The initial O 3 concentration was more important than the contact time, and a reduction of the initial O 3 concentration could not be compensated by increasing the contact time. The Ct values were compared over a narrow range of initial concentrations; the Ct values could only be contrasted when the initial O 3 concentrations were very similar. A higher initial O 3 concentration led to a higher inflection point value for the lnN/N 0 vs C 0 t curve. Energy consumption using a plasma corona was lower than when using boron-doped diamond electrodes. Copyright © 2016 Elsevier Ltd. All rights reserved.
SU-F-T-626: Intracranial SRS Re-Treatment Without Acquisition of New CT Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiant, D; Manning, M; Liu, H
Purpose: Linear accelerator based stereotactic radiosurgery (SRS) for multiple intracranial lesions with frequent surveillance is becoming a popular treatment option. This strategy leads to retreatment with SRS as new lesions arise. Currently, each course of treatment uses magnetic resonance (MR) and computed tomography (CT) images for treatment planning. We propose that new MR images, with course 1 CT images, may be used for future treatment plans with negligible loss of dosimetric accuracy. Methods: Ten patients that received multiple courses of SRS were retrospectively reviewed. The treatment plans and contours from non-initial courses were copied to the initial CTs and recalculated.more » Doses metrics for the plans calculated on the initial CTs and later CTs were compared. All CT scans were acquired on a Philips CT scanner with a 600 mm field of view and 1 mm slice thickness (Philips Healthcare, Andover, MA). All targets were planned to 20 Gy and calculated in Eclipse V. 13.6 (Varian, Palo Alto, CA) using analytic anisotropic algorithm with 1 mm calculation grid. Results: Sixteen lesions were evaluated. The mean time between courses was 250 +/− 215 days (range 103–979). The mean target volume was 2.0 +/− 2.9 cc (range 0.1–10.1). The average difference in mean target dose between the two calculations was 0.2 +/− 0.3 Gy (range 0.0 – 1.0). The mean conformity index (CI) was 1.28 +/− 0.14 (range 1.07 – 1.82). The average difference in CI was 0.03 +/− 0.16 (range 0.00 – 0.44). Targets volumes < 0.5 cc showed the largest changes in both metrics. Conclusion: Continued treatment based on initial CT images is feasible. Dose calculation on the initial CT for future treatments provides reasonable dosimetric accuracy. Changes in dose metrics are largest for small volumes, and are likely dominated by partial volume effects in target definition.« less
Avanesov, Maxim; Weinrich, Julius M; Kraus, Thomas; Derlin, Thorsten; Adam, Gerhard; Yamamura, Jin; Karul, Murat
2016-11-01
The purpose of the retrospective study was to evaluate the additional value of dual-phase multidetector computed tomography (MDCT) protocols over a single-phase protocol on initial MDCT in patients with acute pancreatitis using three CT-based pancreatitis severity scores with regard to radiation dose. In this retrospective, IRB approved study MDCT was performed in 102 consecutive patients (73 males; 55years, IQR48-64) with acute pancreatitis. Inclusion criteria were CT findings of interstitial edematous pancreatitis (IP) or necrotizing pancreatitis (NP) and a contrast-enhanced dual-phase (arterial phase and portal-venous phase) abdominal CT performed at ≥72h after onset of symptoms. The severity of pancreatic and extrapancreatic changes was independently assessed by 2 observers using 3 validated CT-based scoring systems (CTSI, mCTSI, EPIC). All scores were applied to arterial phase and portal venous phase scans and compared to score results of portal venous phase scans, assessed ≥14days after initial evaluation. For effective dose estimation, volume CT dose index (CTDIvol) and dose length product (DLP) were recorded in all examinations. In neither of the CT severity scores a significant difference was observed after application of a dual-phase protocol compared with a single-phase protocol (IP: CTSI: 2.7 vs. 2.5, p=0.25; mCTSI: 4.0 vs. 4.0, p=0.10; EPIC: 2.0 vs. 2.0, p=0.41; NP: CTSI: 8.0 vs. 7.0, p=0.64; mCTSI: 8.0 vs. 8.0, p=0.10; EPIC: 3.0 vs. 3.0, p=0.06). The application of a single-phase CT protocol was associated with a median effective dose reduction of 36% (mean dose reduction 31%) compared to a dual-phase CT scan. An initial dual-phase abdominal CT after ≥72h after onset of symptoms of acute pancreatitis was not superior to a single-phase protocol for evaluation of the severity of pancreatic and extrapancreatic changes. However, the effective radiation dose may be reduced by 36% using a single-phase protocol. Copyright © 2016. Published by Elsevier Ireland Ltd.
18F-FDG PET/CT in breast cancer: Evidence-based recommendations in initial staging.
Caresia Aroztegui, Ana Paula; García Vicente, Ana María; Alvarez Ruiz, Soledad; Delgado Bolton, Roberto Carlos; Orcajo Rincon, Javier; Garcia Garzon, Jose Ramon; de Arcocha Torres, Maria; Garcia-Velloso, Maria Jose
2017-10-01
Current guidelines do not systematically recommend 18F-FDG PET/CT for breast cancer staging; and the recommendations and level of evidence supporting its use in different groups of patients vary among guidelines. This review summarizes the evidence about the role of 18F-FDG PET/CT in breast cancer staging and the therapeutic and prognostic impact accumulated in the last decade. Other related aspects, such as the association of metabolic information with biology and prognosis are considered and evidence-based recommendations for the use of 18F-FDG PET/CT in breast cancer staging are offered. We systematically searched MEDLINE for articles reporting studies with at least 30 patients related to clinical questions following the Problem/Population, Intervention, Comparison, and Outcome framework. We critically reviewed the selected articles and elaborated evidence tables structuring the summarized information into methodology, results, and limitations. The level of evidence and the grades of recommendation for the use of 18F-FDG PET/CT in different contexts are summarized. Level III evidence supports the use of 18F-FDG PET/CT for initial staging in patients with recently diagnosed breast cancer; the diagnostic and therapeutic impact of the 18F-FDG PET/CT findings is sufficient for a weak recommendation in this population. In patients with locally advanced breast cancer, level II evidence supports the use of 18F-FDG PET/CT for initial staging; the diagnostic and therapeutic impact of the 18F-FDG PET/CT findings is sufficient for a strong recommendation in this population. In patients with recently diagnosed breast cancer, the metabolic information from baseline 18F-FDG PET/CT is associated with tumor biology and has prognostic implications, supported by level II evidence. In conclusion, 18F-FDG PET/CT is not recommended for staging all patients with early breast cancer, although evidence of improved regional and systemic staging supports its use in locally advanced breast cancer. Baseline tumor glycolytic activity is associated with tumor biology and prognosis.
Evaluation of Prostate Cancer with 11C- and 18F-Choline PET/CT: Diagnosis and Initial Staging.
Nitsch, Sascha; Hakenberg, Oliver W; Heuschkel, Martin; Dräger, Desiree; Hildebrandt, Guido; Krause, Bernd J; Schwarzenböck, Sarah M
2016-10-01
Early diagnosis and adequate staging are crucial for the choice of adequate treatment in prostate cancer (PC). Morphologic and functional imaging modalities, such as CT and MRI, have had limited accuracy in the diagnosis and nodal staging of PC. Molecular PET/CT imaging with 11 C- or 18 F-choline-labeled derivatives is increasingly being used, but its role in the diagnosis and initial staging of PC is controversial because of limitations in sensitivity and specificity for the detection of primary PC. For T staging, functional MRI is superior to 11 C- or 18 F-choline PET/CT. For N staging, 11 C- or 18 F-choline PET/CT can provide potentially useful information that may influence treatment planning. For the detection of bone metastases, 11 C- or 18 F-choline PET/CT has had promising results; however, in terms of cost-effectiveness, the routine use of 11 C- or 18 F-choline PET/CT is still debatable. 11 C- or 18 F-choline PET/CT might be used in high-risk PC before radiation treatment planning, potentially affecting this planning (e.g., regarding dose escalation). This review provides an overview of the diagnostic accuracy and limitations of 11 C- or 18 F-choline PET/CT in the diagnosis and staging of PC. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Thoracoabdominal Computed Tomography in Trauma Patients: A Cost-Consequences Analysis
van Vugt, Raoul; Kool, Digna R.; Brink, Monique; Dekker, Helena M.; Deunk, Jaap; Edwards, Michael J.
2014-01-01
Background: CT is increasingly used during the initial evaluation of blunt trauma patients. In this era of increasing cost-awareness, the pros and cons of CT have to be assessed. Objectives: This study was performed to evaluate cost-consequences of different diagnostic algorithms that use thoracoabdominal CT in primary evaluation of adult patients with high-energy blunt trauma. Materials and Methods: We compared three different algorithms in which CT was applied as an immediate diagnostic tool (rush CT), a diagnostic tool after limited conventional work-up (routine CT), and a selective tool (selective CT). Probabilities of detecting and missing clinically relevant injuries were retrospectively derived. We collected data on radiation exposure and performed a micro-cost analysis on a reference case-based approach. Results: Both rush and routine CT detected all thoracoabdominal injuries in 99.1% of the patients during primary evaluation (n = 1040). Selective CT missed one or more diagnoses in 11% of the patients in which a change of treatment was necessary in 4.8%. Rush CT algorithm costed € 2676 (US$ 3660) per patient with a mean radiation dose of 26.40 mSv per patient. Routine CT costed € 2815 (US$ 3850) and resulted in the same radiation exposure. Selective CT resulted in less radiation dose (23.23 mSv) and costed € 2771 (US$ 3790). Conclusions: Rush CT seems to result in the least costs and is comparable in terms of radiation dose exposure and diagnostic certainty with routine CT after a limited conventional work-up. However, selective CT results in less radiation dose exposure but a slightly higher cost and less certainty. PMID:25337521
A Hybrid Method for Pancreas Extraction from CT Image Based on Level Set Methods
Tan, Hanqing; Fujita, Hiroshi
2013-01-01
This paper proposes a novel semiautomatic method to extract the pancreas from abdominal CT images. Traditional level set and region growing methods that request locating initial contour near the final boundary of object have problem of leakage to nearby tissues of pancreas region. The proposed method consists of a customized fast-marching level set method which generates an optimal initial pancreas region to solve the problem that the level set method is sensitive to the initial contour location and a modified distance regularized level set method which extracts accurate pancreas. The novelty in our method is the proper selection and combination of level set methods, furthermore an energy-decrement algorithm and an energy-tune algorithm are proposed to reduce the negative impact of bonding force caused by connected tissue whose intensity is similar with pancreas. As a result, our method overcomes the shortages of oversegmentation at weak boundary and can accurately extract pancreas from CT images. The proposed method is compared to other five state-of-the-art medical image segmentation methods based on a CT image dataset which contains abdominal images from 10 patients. The evaluated results demonstrate that our method outperforms other methods by achieving higher accuracy and making less false segmentation in pancreas extraction. PMID:24066016
Strunk, Daniel R; Hollars, Shannon N; Adler, Abby D; Goldstein, Lizabeth A; Braun, Justin D
2014-10-01
In Cognitive Therapy (CT), therapists work to help patients develop skills to cope with negative affect. Most current methods of assessing patients' skills are cumbersome and impractical for clinical use. To address this issue, we developed and conducted an initial psychometric evaluation of self and therapist reported versions of a new measure of CT skills: the Competencies of Cognitive Therapy Scale (CCTS). We evaluated the CCTS at intake and post-treatment in a sample of 67 patients participating in CT. The CCTS correlated with a preexisting measure of CT skills (the Ways of Responding Questionnaire) and was also related to concurrent depressive symptoms. Across CT, self-reported improvements in CT competencies were associated with greater changes in depressive symptoms. These findings offer initial evidence for the validity of the CCTS. We discuss the CCTS in comparison with other measures of CT skills and suggest future research directions.
Strunk, Daniel R.; Hollars, Shannon N.; Adler, Abby D.; Goldstein, Lizabeth A.; Braun, Justin D.
2014-01-01
In Cognitive Therapy (CT), therapists work to help patients develop skills to cope with negative affect. Most current methods of assessing patients’ skills are cumbersome and impractical for clinical use. To address this issue, we developed and conducted an initial psychometric evaluation of self and therapist reported versions of a new measure of CT skills: the Competencies of Cognitive Therapy Scale (CCTS). We evaluated the CCTS at intake and post-treatment in a sample of 67 patients participating in CT. The CCTS correlated with a preexisting measure of CT skills (the Ways of Responding Questionnaire) and was also related to concurrent depressive symptoms. Across CT, self-reported improvements in CT competencies were associated with greater changes in depressive symptoms. These findings offer initial evidence for the validity of the CCTS. We discuss the CCTS in comparison with other measures of CT skills and suggest future research directions. PMID:25408560
Martin, C A; Gabrillargues, J; Louvrier, C; Saroul, N; Mom, T; Gilain, L
2014-11-01
This study was designed to analyse the contribution of CT scan to the management of retropharyngeal abscess in children and the place of CT-guided percutaneous aspiration as an alternative to surgical drainage. Retrospective study including 18 children with a mean age of 38 months [range: 5-67 months] presenting with retropharyngeal infection between 2006 and 2011. All cases were initially assessed by contrast-enhanced CT scan of the neck. Clinical, radiological treatment and bacteriological data were collected. Radiological results were correlated with surgical and percutaneous aspiration findings (presence or absence of an abscess). The initial CT scan detected 14 abscesses, 3 cases of non-suppurative lymphadenitis and one case of retropharyngeal oedema. One case of non-suppurative lymphadenitis progressed to abscess after failure of antibiotic therapy and was treated surgically. Surgical drainage revealed a purulent collection in 11 cases and no collection in 3 cases. Four CT-guided percutaneous aspirations were successfully performed. Three cases were treated by antibiotics alone (2 cases of lymphadenitis and 1 case of retropharyngeal oedema). Bacteriological examinations revealed the presence of Streptococcus pyogenes in 78.5% of cases. The positive predictive value of the initial CT scan was 78.8% in our series. Contrast-enhanced neck CT scan confirmed the diagnosis of retropharyngeal abscess and the indication for surgical drainage. It must be performed urgently, on admission. When it is decided to treat the patient with antibiotics alone, follow-up imaging should be performed in the absence of improvement 24 to 48 hours after starting antibiotics. CT-guided percutaneous aspiration is both a diagnostic modality confirming abscess formation of an inflammatory lesion of the retropharyngeal space as well as a therapeutic tool, sometimes avoiding the need for surgical drainage. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nichol, Alan M.; Warde, Padraig R.; Lockwood, Gina A.
Purpose: To determine the reduction of prostate motion during a typical radiotherapy (RT) fraction from a bowel regimen comprising an antiflatulent diet and daily milk of magnesia. Methods and Materials: Forty-two patients with T1c-T2c prostate cancer voided the bladder and rectum before three cinematic magnetic resonance imaging scans obtained every 9 s for 9 min in a vacuum immobilization device. The MRIs were at baseline without bowel regimen (MRI-BL), before CT planning with bowel regimen (MRI-CT), and before a randomly assigned RT fraction (1-42) with bowel regimen (MRI-RT). A single observer tracked displacement of the posterior midpoint (PM) of themore » prostate. The primary endpoints were comparisons of the proportion of time that the PM was displaced >3 mm (PTPM3) from its initial position, and the secondary endpoints were comparisons of the reduction of initial rectal area, with and without the bowel regimen. Results: The mean rectal area was: 13.5 cm{sup 2} at MRI-BL, 12.7 cm{sup 2} at MRI-CT, and 12.3 cm{sup 2} at MRI-RT (MRI-BL vs. MRI-CT, p = 0.11; MRI-BL vs. MRI-CT, p = 0.07). Moving rectal gas alone (56%) and moving gas and stool (18%) caused 74% of intrafraction prostate motion. The PTPM3 was 11.3% at MRI-BL, 4.8% at MRI-CT, and 12.0% at MRI-RT (MRI-BL vs. MRI-CT, p = 0.12; MRI-BL vs. MRI-RT, p = 0.89). Conclusion: For subjects voiding their rectum before imaging, an antiflatulent diet and milk of magnesia laxative did not significantly reduce initial rectal area or intrafraction prostate motion.« less
Gastrointestinal motor inhibition by exogenous human, salmon, and eel calcitonin in conscious dogs.
Nakamura, H; Asano, T; Haruta, K; Takeda, K
1995-01-01
Effects of synthetic eel (E-), salmon (S-), and human (H-) calcitonin (CT) on gastrointestinal motility were studied in conscious beagle dogs, which had been implanted with strain gauge force transducers. Intramuscular administration of E-, S-, or H-CT interrupted gastric migrating motor complexes, digestive pattern, and gastric emptying. The order of potency was E-CT = S-CT > H-CT. Motor inhibition induced by CT occurred independently of plasma immunoreactive motilin levels or hypocalcemia. In addition, E-CT and S-CT induced vomiting without a retrograde giant contraction (RGC) during the postprandial state. Apomorphine or CuSO4 initiated RGC prior to vomiting. RGC induced by apomorphine was inhibited by pretreatment with E-CT as well as hexamethonium, atropine, or surgical vagotomy. E-CT showed no inhibitory effect on nicotine stimulated contraction of isolated guinea-pig ileum. These results suggest that peripherally administered CT inhibits canine gastrointestinal motility at the central nervous system level by lowering vagal activity.
Computed tomographic imaging in the pediatric patient with a seatbelt sign: still not good enough.
Kopelman, Tammy R; Jamshidi, Ramin; Pieri, Paola G; Davis, Karole; Bogert, James; Vail, Sydney J; Gridley, Daniel; Singer Pressman, Melissa A
2018-02-01
Considering the improvements in CT over the past decade, this study aimed to determine whether CT can diagnose HVI in pediatric trauma patients with seatbelt signs (SBS). We retrospectively identified pediatric patients with SBS who had abdominopelvic CT performed on initial evaluation over 5 1/2years. Abnormal CT was defined by identification of any intra-abdominal abnormality possibly related to trauma. One hundred twenty patients met inclusion criteria. CT was abnormal in 38/120 (32%) patients: 34 scans had evidence of HVI and 6 showed solid organ injury (SOI). Of the 34 with suspicion for HVI, 15 (44%) had small amounts of isolated pelvic free fluid as the only abnormal CT finding; none required intervention. Ultimately, 16/120 (13%) patients suffered HVI and underwent celiotomy. Three patients initially had a normal CT but required celiotomy for clinical deterioration within 20h of presentation. False negative CT rate was 3.6%. The sensitivity, specificity and accuracy of CT to diagnose significant HVI in the presence of SBS were 81%, 80%, and 80%, respectively. Despite improvements in CT, pediatric patients with SBS may have HVI not evident on initial CT confirming the need to observation for delayed manifestation of HVI. Level II Study of a Diagnostic Test. Copyright © 2017 Elsevier Inc. All rights reserved.
Kohlmeier, Carsten; Behrens, Peter; Böger, Andreas; Ramachandran, Brinda; Caparso, Anthony; Schulze, Dirk; Stude, Philipp; Heiland, Max; Assaf, Alexandre T
2017-12-01
The ATI SPG microstimulator is designed to be fixed on the posterior maxilla, with the integrated lead extending into the pterygopalatine fossa to electrically stimulate the sphenopalatine ganglion (SPG) as a treatment for cluster headache. Preoperative surgical planning to ensure the placement of the microstimulator in close proximity (within 5 mm) to the SPG is critical for treatment efficacy. The aim of this study was to improve the surgical procedure by navigating the initial dissection prior to implantation using a passive optical navigation system and to match the post-operative CBCT images with the preoperative treatment plan to verify the accuracy of the intraoperative placement of the microstimulator. Custom methods and software were used that result in a 3D rotatable digitally reconstructed fluoroscopic image illustrating the patient-specific placement with the ATI SPG microstimulator. Those software tools were preoperatively integrated with the planning software of the navigation system to be used intraoperatively for navigated placement. Intraoperatively, the SPG microstimulator was implanted by completing the initial dissection with CT navigation, while the final position of the stimulator was verified by 3D CBCT. Those reconstructed images were then immediately matched with the preoperative CT scans with the digitally inserted SPG microstimulator. This method allowed for visual comparison of both CT scans and verified correct positioning of the SPG microstimulator. Twenty-four surgeries were performed using this new method of CT navigated assistance during SPG microstimulator implantation. Those results were compared to results of 21 patients previously implanted without the assistance of CT navigation. Using CT navigation during the initial dissection, an average distance reduction of 1.2 mm between the target point and electrode tip of the SPG microstimulator was achieved. Using the navigation software for navigated implantation and matching the preoperative planned scans with those performed post-operatively, the average distance was 2.17 mm with navigation, compared to 3.37 mm in the 28 surgeries without navigation. Results from this new procedure showed a significant reduction (p = 0.009) in the average distance from the SPG microstimulator to the desired target point. Therefore, a distinct improvement could be achieved in positioning of the SPG microstimulator through the use of intraoperative navigation during the initial dissection and by post-operative matching of pre- and post-operatively performed CBCT scans.
Papaioannou, Anastasios; Kuyucak, Serdar; Kuncic, Zdenka
2015-01-01
A sequence of complex conformational changes is required for insulin to bind to the insulin receptor. Recent experimental evidence points to the B chain C-terminal (BC-CT) as the location of these changes in insulin. Here, we present molecular dynamics simulations of insulin that reveal new insights into the structural changes occurring in the BC-CT. We find three key results: 1) The opening of the BC-CT is inherently stochastic and progresses through an open and then a "wide-open" conformation--the wide-open conformation is essential for receptor binding, but occurs only rarely. 2) The BC-CT opens with a zipper-like mechanism, with a hinge at the Phe24 residue, and is maintained in the dominant closed/inactive state by hydrophobic interactions of the neighboring Tyr26, the critical residue where opening of the BC-CT (activation of insulin) is initiated. 3) The mutation Y26N is a potential candidate as a therapeutic insulin analogue. Overall, our results suggest that the binding of insulin to its receptor is a highly dynamic and stochastic process, where initial docking occurs in an open conformation and full binding is facilitated through interactions of insulin receptor residues with insulin in its wide-open conformation.
Zapata, Claudia P; Cuglievan, Branko; Zapata, Catalina M; Olavarrieta, Raquel; Raskin, Scott; Desai, Kavita; De Angulo, Guillermo
2018-02-01
Accurate staging is essential in the prognosis and management of pediatric malignancies. Current protocols require screening for marrow infiltration with bone marrow biopsy (BMB) as the gold standard. Positron emission tomography-computed tomography (PET-CT) is commonly used to complete the staging process and can also be used to evaluate marrow infiltration. To compare PET-CT and BMB in the initial evaluation of bone marrow infiltration in pediatric cancers. We retrospectively reviewed new cases of EWS, rhabdomyosarcoma, neuroblastoma, and lymphoma diagnosed between January 2009 and October 2014. Each case had undergone both PET-CT and BMB within 4 weeks without treatment in the interval between screening modalities. We reviewed 69 cases. Bone marrow infiltration was demonstrated in 34 cases by PET-CT and in 18 cases by BMB. The sensitivity and negative predictive value of PET-CT were both 100%. Interestingly, the cases in which infiltration was not detected on BMB had an abnormal marrow signal on PET-CT focal or distant to iliac crest. PET-CT has a high sensitivity when assessing marrow infiltration in pediatric malignancies. Advances in radiologic modalities may obviate the use of invasive, painful, and costly procedures like BMB. Furthermore, biopsy results are limited by insufficient tissue or the degree of marrow infiltration (diffuse vs. focal disease). PET-CT can improve the precision of biopsy when used as a guiding tool. This study proposes the use of PET-CT as first-line screening for bone marrow infiltration to improve the accuracy of staging in new diagnoses. © 2017 Wiley Periodicals, Inc.
Translation initiation mediated by nuclear cap-binding protein complex.
Ryu, Incheol; Kim, Yoon Ki
2017-04-01
In mammals, cap-dependent translation of mRNAs is initiated by two distinct mechanisms: cap-binding complex (CBC; a heterodimer of CBP80 and 20)-dependent translation (CT) and eIF4E-dependent translation (ET). Both translation initiation mechanisms share common features in driving cap- dependent translation; nevertheless, they can be distinguished from each other based on their molecular features and biological roles. CT is largely associated with mRNA surveillance such as nonsense-mediated mRNA decay (NMD), whereas ET is predominantly involved in the bulk of protein synthesis. However, several recent studies have demonstrated that CT and ET have similar roles in protein synthesis and mRNA surveillance. In a subset of mRNAs, CT preferentially drives the cap-dependent translation, as ET does, and ET is responsible for mRNA surveillance, as CT does. In this review, we summarize and compare the molecular features of CT and ET with a focus on the emerging roles of CT in translation. [BMB Reports 2017; 50(4): 186-193].
Vorster, Mariza; Modiselle, Moshe; Ebenhan, Thomas; Wagener, Carl; Sello, That; Zeevaart, Jan Rijn; Moshokwa, Evelyn; Sathekge, Mike Machaba
2015-01-01
Imaging with fluorine-18-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) has, until recently provided disappointing results with low sensitivity ranging from 31%-64% in patients with well-differentiated prostate cancer (PC) at all prostatic specific antigen (PSA) levels while fluorine-18-fluoroethylcholine ((18)F-FECh) PET/CT showed about 85% sensitivity in restaging patients after relapse. We present our experience of the sensitivity of (18)F-FECh PET/CT in the early stages of PC. Fifty patients were prospectively recruited and imaged, of which 40 fulfilled all inclusion criteria. Our patients had an average age of 65.5 years. Fifteen patients were referred for initial staging, with the remaining 25 referred for restaging and all patients had histologically confirmed adenocarcinoma. Patients were imaged by (18)F-FECh PET/CT. Findings were evaluated qualitatively and quantitatively and compared to the results of histology, PSA, Gleason score and bone scintigraphy. The prostate SUVmax was also used. Thirty-one patients demonstrated abnormal pelvic- and or extra- pelvic findings on (18)F-FECh PET/CT, which was consistent with malignant or metastatic involvement. The prostate SUVmax could not be used to predict the presence or absence of metastatic disease. Findings of this paper suggest that (18)F-FECh PET/CT in 30/40 cases (estimated as 75%) was helpful in the initial staging, restaging and lymph node detection of patients with PC. The SUVmax was not helpful. We diagnosed more PC cases in our African-American patients as compared to the Caucasian patients.
Harding-Esch, Emma; Jofre-Bonet, Mireia; Dhanjal, Jaskiran K.; Burr, Sarah; Edwards, Tansy; Holland, Martin; Sillah, Ansumana; West, Sheila; Lietman, Tom; Keenan, Jeremy; Mabey, David; Bailey, Robin
2015-01-01
Background Mass drug administration (MDA) treatment of active trachoma with antibiotic is recommended to be initiated in any district where the prevalence of trachoma inflammation, follicular (TF) is ≥10% in children aged 1–9 years, and then to continue for at least three annual rounds before resurvey. In The Gambia the PRET study found that discontinuing MDA based on testing a sample of children for ocular Chlamydia trachomatis(Ct) infection after one MDA round had similar effects to continuing MDA for three rounds. Moreover, one round of MDA reduced disease below the 5% TF threshold. We compared the costs of examining a sample of children for TF, and of testing them for Ct, with those of MDA rounds. Methods The implementation unit in PRET The Gambia was a census enumeration area (EA) of 600–800 people. Personnel, fuel, equipment, consumables, data entry and supervision costs were collected for census and treatment of a sample of EAs and for the examination, sampling and testing for Ct infection of 100 individuals within them. Programme costs and resource savings from testing and treatment strategies were inferred for the 102 EAs in the study area, and compared. Results Census costs were $103.24 per EA plus initial costs of $108.79. MDA with donated azithromycin cost $227.23 per EA. The mean cost of examining and testing 100 children was $796.90 per EA, with Ct testing kits costing $4.80 per result. A strategy of testing each EA for infection is more expensive than two annual rounds of MDA unless the kit cost is less than $1.38 per result. However stopping or deciding not to initiate treatment in the study area based on testing a sample of EAs for Ct infection (or examining children in a sample of EAs) creates savings relative to further unnecessary treatments. Conclusion Resources may be saved by using tests for chlamydial infection or clinical examination to determine that initial or subsequent rounds of MDA for trachoma are unnecessary. PMID:25901349
Pulmonary Toxocariasis: Initial and Follow-Up CT Findings in 63 Patients.
Lee, Kyung Hee; Kim, Tae Jung; Lee, Kyung Won
2015-06-01
The objective of our study was to describe the characteristic radiologic findings of pulmonary toxocariasis on initial and follow-up chest CT. Between June 2010 and May 2014, 63 patients with serologically proven, clinically diagnosed pulmonary toxocariasis and chest CT examinations performed within 2 months of an enzyme-linked immunosorbent assay for toxocariasis were identified. Two chest radiologists retrospectively analyzed the chest CT examinations in consensus; they focused on the distribution, location, number, and internal characteristics of the pulmonary lesions. The pulmonary lesions tended to involve three or more lobes (49% [31/63]) on the initial CT; predominance of the abnormalities in a subpleural location (81% [51/63]) and in the lower lung zone (98% [62/63]) was noted. The number of pulmonary lesions per patient were from two to five (46% [29/63]), more than five (32% [20/63]), or one (22% [14/63]). The radiologic findings of pulmonary toxocariasis could be categorized into four different patterns: ground-glass opacities (GGOs), solid nodules, consolidations, and linear opacities. The most common pattern was ill-defined GGOs with or without solid portions (84% [53/63]). The solid nodule and patchy consolidation patterns were found in 29% (18/63) and 21% (13/63) of patients, respectively. In addition, linear opacities (1-2 mm thick and 8-25 mm long) were present in 19% of patients (12/63); this finding is a subtle, yet novel, finding. On follow-up CT, the pulmonary lesions had either disappeared or migrated; when they had migrated, they revealed radiologic manifestations similar to the findings on the initial CT. Pulmonary toxocariasis manifested as multiple lesions in four radiologic patterns with subpleural and lower lung predominance on initial and follow-up CT. A linear opacity may be one of many clues in the diagnosis of pulmonary toxocariasis on CT.
Comprehensive CT Evaluation in Acute Ischemic Stroke: Impact on Diagnosis and Treatment Decisions
Löve, Askell; Siemund, Roger; Andsberg, Gunnar; Cronqvist, Mats; Holtås, Stig; Björkman-Burtscher, Isabella
2011-01-01
Background. With modern CT imaging a comprehensive overview of cerebral macro- and microcirculation can be obtained within minutes in acute ischemic stroke. This opens for patient stratification and individualized treatment. Methods. Four patients with acute ischemic stroke of different aetiologies and/or treatments were chosen for illustration of the comprehensive CT protocol and its value in subsequent treatment decisions. The patients were clinically evaluated according to the NIHSS-scale, examined with the comprehensive CT protocol including both CT angiography and CT perfusion, and followed up by MRI. Results. The comprehensive CT examination protocol increased the examination time but did not delay treatment initiation. In some cases CT angiography revealed the cause of stroke while CT perfusion located and graded the perfusion defect with reasonable accuracy, confirmed by follow-up MR-diffusion. In the presented cases findings of the comprehensive CT examination influenced the treatment strategy. Conclusions. The comprehensive CT examination is a fast and safe method allowing accurate diagnosis and making way for individualized treatment in acute ischemic stroke. PMID:21603175
Automatic initialization for 3D bone registration
NASA Astrophysics Data System (ADS)
Foroughi, Pezhman; Taylor, Russell H.; Fichtinger, Gabor
2008-03-01
In image-guided bone surgery, sample points collected from the surface of the bone are registered to the preoperative CT model using well-known registration methods such as Iterative Closest Point (ICP). These techniques are generally very sensitive to the initial alignment of the datasets. Poor initialization significantly increases the chances of getting trapped local minima. In order to reduce the risk of local minima, the registration is manually initialized by locating the sample points close to the corresponding points on the CT model. In this paper, we present an automatic initialization method that aligns the sample points collected from the surface of pelvis with CT model of the pelvis. The main idea is to exploit a mean shape of pelvis created from a large number of CT scans as the prior knowledge to guide the initial alignment. The mean shape is constant for all registrations and facilitates the inclusion of application-specific information into the registration process. The CT model is first aligned with the mean shape using the bilateral symmetry of the pelvis and the similarity of multiple projections. The surface points collected using ultrasound are then aligned with the pelvis mean shape. This will, in turn, lead to initial alignment of the sample points with the CT model. The experiments using a dry pelvis and two cadavers show that the method can align the randomly dislocated datasets close enough for successful registration. The standard ICP has been used for final registration of datasets.
Mata-Mbemba, Daddy; Mugikura, Shunji; Nakagawa, Atsuhiro; Murata, Takaki; Ishii, Kiyoshi; Kushimoto, Shigeki; Tominaga, Teiji; Takahashi, Shoki; Takase, Kei
2018-01-05
OBJECTIVE The objective of this study was to test the hypothesis that midline (interhemispheric or perimesencephalic) traumatic subarachnoid hemorrhage (tSAH) on initial CT may implicate the same shearing mechanism that underlies severe diffuse axonal injury (DAI). METHODS The authors enrolled 270 consecutive patients (mean age [± SD] 43 ± 23.3 years) with a history of head trauma who had undergone initial CT within 24 hours and brain MRI within 30 days. Six initial CT findings, including intraventricular hemorrhage (IVH) and tSAH, were used as candidate predictors of DAI. The presence of tSAH was determined at the cerebral convexities, sylvian fissures, sylvian vallecula, cerebellar folia, interhemispheric fissure, and perimesencephalic cisterns. Following MRI, patients were divided into negative and positive DAI groups, and were assigned to a DAI stage: 1) stage 0, negative DAI; 2) stage 1, DAI in lobar white matter or cerebellum; 3) stage 2, DAI involving the corpus callosum; and 4) stage 3, DAI involving the brainstem. Glasgow Outcome Scale-Extended (GOSE) scores were obtained in 232 patients. RESULTS Of 270 patients, 77 (28.5%) had DAI; tSAH and IVH were independently associated with DAI (p < 0.05). Of tSAH locations, midline tSAH was independently associated with both overall DAI and DAI stage 2 or 3 (severe DAI; p < 0.05). The midline tSAH on initial CT had sensitivity of 60.8%, specificity of 81.7%, and positive and negative predictive values of 43.7% and 89.9%, respectively, for severe DAI. When adjusted for admission Glasgow Coma Score, the midline tSAH independently predicted poor GOSE score at both hospital discharge and after 6 months. CONCLUSIONS Midline tSAH could implicate the same shearing mechanism that underlies severe DAI, for which midline tSAH on initial CT is a probable surrogate.
Dutta, Pinaki R; Riaz, Nadeem; McBride, Sean; Morris, Luc G; Patel, Snehal; Ganly, Ian; Wong, Richard J; Palmer, Frank; Schöder, Heiko; Lee, Nancy
2016-04-01
The purpose of this study was for us to present our evaluation of the effectiveness of positron emission tomography (PET)/CT imaging in postoperative patients with oral cavity squamous cell carcinoma (SCC) before initiating adjuvant radiation therapy. Treatment planning PET/CT scans were obtained in 44 patients with oral cavity SCC receiving adjuvant radiation. We identified target areas harboring macroscopic disease requiring higher radiation doses or additional surgery. Fourteen PET/CT scans were abnormal. Thirteen patients underwent surgery and/or biopsy, increased radiation dose, and/or addition of chemotherapy. Eleven patients received higher radiation doses. Patients undergoing imaging >8 weeks were more likely to have abnormal results (p = .01). One-year distant metastases-free survival was significantly worse in patients with positive PET/CT scans (61.5% vs 92.7%; p = .01). The estimated positive predictive value (PPV) was 38% for postoperative PET/CT scanning. We demonstrated that 32% of patients have abnormal PET/CT scans resulting in management changes. Patients may benefit from postoperative PET/CT imaging to optimize adjuvant radiation treatment planning. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1285-E1293, 2016. © 2015 Wiley Periodicals, Inc.
Kumar, Arvind; Jindal, Tarun; Dutta, Roman; Kumar, Rakesh
2009-10-01
To evaluate the role of combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in differentiating bronchial tumors observed in contrast enhanced computed tomography scan of chest. Prospective observational study. Place of study: All India Institute of Medical Sciences, New Delhi, India. 7 patients with bronchial mass detected in computed tomography scan of the chest were included in this study. All patients underwent (18)F-FDG PET-CT scan, (68)Ga DOTA-TOC PET-CT scan and fiberoptic bronchoscope guided biopsy followed by definitive surgical excision. The results of functional imaging studies were analyzed and the results are correlated with the final histopathology of the tumor. Histopathological examination of 7 bronchial masses revealed carcinoid tumors (2 typical, 1 atypical), inflammatory myofibroblastic tumor (1), mucoepidermoid carcinoma (1), hamartoma (1), and synovial cell sarcoma (1). The typical carcinoids had mild (18)F-FDG uptake and high (68)Ga DOTA-TOC uptake. Atypical carcinoid had moderate uptake of (18)F-FDG and high (68)Ga DOTA-TOC uptake. Inflammatory myofibroblastic tumor showed high uptake of (18)F-FDG and no uptake of (68)Ga DOTA-TOC. Mucoepidermoid carcinoma showed mild (18)F-FDG uptake and no (68)Ga DOTA-TOC uptake. Hamartoma showed no uptake on either scans. Synovial cell sarcoma showed moderate (18)F-FDG uptake and mild focal (68)Ga DOTA-TOC uptake. This initial experience with the combined use of (18)F-FDG and (68)Ga DOTA-TOC PET-CT scan reveals different uptake patterns in various bronchial tumors. Bronchoscopic biopsy will continue to be the gold standard; however, the interesting observations made in this study merits further evaluation of the utility of the combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in larger number of patients with bronchial masses.
Lantos, Joshua E; Levine, Marc S; Rubesin, Stephen E; Lau, Charles T; Torigian, Drew A
2013-03-01
To assess the diagnostic performance of esophagography and chest computed tomography (CT) for detecting leaks after esophagectomy and gastric pull-through. Our database revealed 29 patients who had undergone esophagography and chest CT after esophagectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative leaks were determined for esophagography and CT, separately and combined, on the basis of a retrospective image review. Patients were also stratified for esophagograms with water-soluble contrast alone versus water-soluble contrast and high-density barium and for CT with and without oral contrast. Our findings were retrospectively compared with those reported at initial image interpretation. Clinically relevant leaks were present in 14 (48%) of 29 patients after esophagectomy. Esophagography had a sensitivity of 79%, specificity of 73%, PPV of 73%, and NPV of 79% for detecting leaks, whereas CT had a sensitivity of 86%, specificity of 33%, PPV of 55%, and NPV of 71% and esophagography and CT combined had a sensitivity of 100%, specificity of 27%, PPV of 56%, and NPV of 100%. The sensitivity of esophagography increased with high-density barium, whereas the sensitivity of CT was the same with and without oral contrast agent. Finally, esophagography and CT were seen to have a higher sensitivity and lower specificity on retrospective review compared with the results reported at initial image interpretation. Esophagography had a slightly lower sensitivity and substantially higher specificity compared with CT for detecting leaks after esophagectomy, whereas esophagography and CT combined had a sensitivity of 100% for detecting leaks. Therefore, postoperative leaks can be excluded with confidence after esophagectomy when both tests are negative.
In vivo 3D PIXE-micron-CT imaging of Drosophila melanogaster using a contrast agent
NASA Astrophysics Data System (ADS)
Matsuyama, Shigeo; Hamada, Naoki; Ishii, Keizo; Nozawa, Yuichiro; Ohkura, Satoru; Terakawa, Atsuki; Hatori, Yoshinobu; Fujiki, Kota; Fujiwara, Mitsuhiro; Toyama, Sho
2015-04-01
In this study, we developed a three-dimensional (3D) computed tomography (CT) in vivo imaging system for imaging small insects with micrometer resolution. The 3D CT imaging system, referred to as 3D PIXE-micron-CT (PIXEμCT), uses characteristic X-rays produced by ion microbeam bombardment of a metal target. PIXEμCT was used to observe the body organs and internal structure of a living Drosophila melanogaster. Although the organs of the thorax were clearly imaged, the digestive organs in the abdominal cavity could not be clearly discerned initially, with the exception of the rectum and the Malpighian tubule. To enhance the abdominal images, a barium sulfate powder radiocontrast agent was added. For the first time, 3D images of the ventriculus of a living D. melanogaster were obtained. Our results showed that PIXEμCT can provide in vivo 3D-CT images that reflect correctly the structure of individual living organs, which is expected to be very useful in biological research.
Brenkman, H J F; Gertsen, E C; Vegt, E; van Hillegersberg, R; van Berge Henegouwen, M I; Gisbertz, S S; Luyer, M D P; Nieuwenhuijzen, G A P; van Lanschot, J J B; Lagarde, S M; de Steur, W O; Hartgrink, H H; Stoot, J H M B; Hulsewe, K W E; Spillenaar Bilgen, E J; van Det, M J; Kouwenhoven, E A; van der Peet, D L; Daams, F; van Sandick, J W; van Grieken, N C T; Heisterkamp, J; van Etten, B; Haveman, J W; Pierie, J P; Jonker, F; Thijssen, A Y; Belt, E J T; van Duijvendijk, P; Wassenaar, E; van Laarhoven, H W M; Wessels, F J; Haj Mohammad, N; van Stel, H F; Frederix, G W J; Siersema, P D; Ruurda, J P
2018-04-20
Initial staging of gastric cancer consists of computed tomography (CT) and gastroscopy. In locally advanced (cT3-4) gastric cancer, fluorodeoxyglucose positron emission tomography with CT (FDG-PET/CT or PET) and staging laparoscopy (SL) may have a role in staging, but evidence is scarce. The aim of this study is to evaluate the impact and cost-effectiveness of PET and SL in addition to initial staging in patients with locally advanced gastric cancer. This prospective observational cohort study will include all patients with a surgically resectable, advanced gastric adenocarcinoma (cT3-4b, N0-3, M0), that are scheduled for treatment with curative intent after initial staging with gastroscopy and CT. The modalities to be investigated in this study is the addition of PET and SL. The primary outcome of this study is the proportion of patients in whom the PET or SL lead to a change in treatment strategy. Secondary outcome parameters are: diagnostic performance, morbidity and mortality, quality of life, and cost-effectiveness of these additional diagnostic modalities. The study recently started in August 2017 with a duration of 36 months. At least 239 patients need to be included in this study to demonstrate that the diagnostic modalities are break-even. Based on the annual number of gastrectomies in the participating centers, it is estimated that approximately 543 patients are included in this study. In this study, it is hypothesized that performing PET and SL for locally advanced gastric adenocarcinomas results in a change of treatment strategy in 27% of patients and an annual cost-reduction in the Netherlands of €916.438 in this patient group by reducing futile treatment. The results of this study may be applicable to all countries with comparable treatment algorithms and health care systems. NCT03208621 . This trial was registered prospectively on June 30, 2017.
NASA Astrophysics Data System (ADS)
Si-Mohamed, Salim; Bar-Ness, Daniel; Sigovan, Monica; Cormode, David P.; Coulon, Philippe; Coche, Emmanuel; Vlassenbroek, Alain; Normand, Gabrielle; Boussel, Loic; Douek, Philippe
2017-11-01
Spectral photon-counting CT (SPCCT) is an emerging X-ray imaging technology that extends the scope of available diagnostic imaging tools. The main advantage of photon-counting CT technology is better sampling of the spectral information from the transmitted spectrum in order to benefit from additional physical information being produced during matter interaction, including photo-electric and Compton effects, and the K-edge effect. The K-edge, which is specific for a given element, is the increase in X-ray absorption of the element above the binding energy between its inner electronic shell and the nucleus. Hence, the spectral information contributes to better characterization of tissues and materials of interest, explaining the excitement surrounding this area of X-ray imaging. Other improvements of SPCCT compared with conventional CT, such as higher spatial resolution, lower radiation exposure and lower noise are also expected to provide benefits for diagnostic imaging. In this review, we describe multi-energy CT imaging, from dual energy to photon counting technology, and our initial experience results using a clinical-scale spectral photon counting CT (SPCCT) prototype system in vitro and in vivo. In addition, possible clinical applications are introduced.
Harding-Esch, Emma; Jofre-Bonet, Mireia; Dhanjal, Jaskiran K; Burr, Sarah; Edwards, Tansy; Holland, Martin; Sillah, Ansumana; West, Sheila; Lietman, Tom; Keenan, Jeremy; Mabey, David; Bailey, Robin
2015-04-01
Mass drug administration (MDA) treatment of active trachoma with antibiotic is recommended to be initiated in any district where the prevalence of trachoma inflammation, follicular (TF) is ≥ 10% in children aged 1-9 years, and then to continue for at least three annual rounds before resurvey. In The Gambia the PRET study found that discontinuing MDA based on testing a sample of children for ocular Chlamydia trachomatis(Ct) infection after one MDA round had similar effects to continuing MDA for three rounds. Moreover, one round of MDA reduced disease below the 5% TF threshold. We compared the costs of examining a sample of children for TF, and of testing them for Ct, with those of MDA rounds. The implementation unit in PRET The Gambia was a census enumeration area (EA) of 600-800 people. Personnel, fuel, equipment, consumables, data entry and supervision costs were collected for census and treatment of a sample of EAs and for the examination, sampling and testing for Ct infection of 100 individuals within them. Programme costs and resource savings from testing and treatment strategies were inferred for the 102 EAs in the study area, and compared. Census costs were $103.24 per EA plus initial costs of $108.79. MDA with donated azithromycin cost $227.23 per EA. The mean cost of examining and testing 100 children was $796.90 per EA, with Ct testing kits costing $4.80 per result. A strategy of testing each EA for infection is more expensive than two annual rounds of MDA unless the kit cost is less than $1.38 per result. However stopping or deciding not to initiate treatment in the study area based on testing a sample of EAs for Ct infection (or examining children in a sample of EAs) creates savings relative to further unnecessary treatments. Resources may be saved by using tests for chlamydial infection or clinical examination to determine that initial or subsequent rounds of MDA for trachoma are unnecessary.
Cheung, Michael K; Ong, Shawn Y; Goyal, Uma; Wertheim, Betsy C; Hsu, Charles C
2017-01-01
Objective Positron emission tomography/computed tomography (PET/CT) imaging for head and neck cancers (HNC) is commonly utilized for post-treatment assessment. Though PET/CT in this setting has been reported to have high negative predictive values (> 90%), positive predictive values have been reported at approximately 50%, leading to high rates of false positivity (FP) and troubling management decisions for both patient and practitioner. The objective of this study was to identify patient, disease, treatment and imaging factors that might be associated with a higher likelihood of FP on initial post-treatment PET/CT imaging for patients treated for HNC. Materials and methods A retrospective chart review was performed on 84 patients treated for HNC who received radiation therapy (RT) as part of their overall management from October 2005 to August 2013. Of the patients screened, 19 were found to have mucosally based squamous cell carcinoma (SCC) with positive initial post-treatment PET/CT studies (23%). Fisher’s exact test was used to analyze the association between categorical variables and FP, including patient's gender, disease laterality, primary tumor site and stage, nodal and overall stage, high dose RT fraction size, number of RT fractions completed, total RT dose, biologically effective dose and timing of PET/CT acquisition. Wilcoxon rank-sum test was used to analyze the association between continuous variables and FP, including patient age, total elapsed days of RT, an amount of infused fluorodeoxyglucose 18F-FDG, pre-PET/CT serum glucose levels, and maximum standardized uptake value SUVmax. Statistically significant findings were those that were deemed p <0.05. Results Among patients with positive initial post-treatment PET/CT scans for treated HNC, there was a lower proportion of higher primary disease stage associated with FP versus true positivity (T-stage 3-4: 20 vs 78%, respectively, p=0.023). We also discovered that 50% of patients that underwent confirmation for FP findings suffered serious complications as a direct consequence of invasive exploratory procedures. Conclusions Although PET/CT is known for its exceptional negative predictive value (> 90%) in the post-treatment setting for HNC, high rates of FP remains a clinical challenge. Our study suggests that tumor stage (T-stage) may impact FP rates in positive initial post-treatment PET/CT scans. We recommend careful multidisciplinary discussion regarding positive PET/CT studies in the post-treatment setting for HNC, particularly if invasive intervention is considered. PMID:28497009
SU-F-T-261: Reconstruction of Initial Photon Fluence Based On EPID Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seliger, T; Engenhart-Cabillic, R; Czarnecki, D
2016-06-15
Purpose: Verifying an algorithm to reconstruct relative initial photon fluence for clinical use. Clinical EPID and CT images were acquired to reconstruct an external photon radiation treatment field. The reconstructed initial photon fluence could be used to verify the treatment or calculate the applied dose to the patient. Methods: The acquired EPID images were corrected for scatter caused by the patient and the EPID with an iterative reconstruction algorithm. The transmitted photon fluence behind the patient was calculated subsequently. Based on the transmitted fluence the initial photon fluence was calculated using a back-projection algorithm which takes the patient geometry andmore » its energy dependent linear attenuation into account. This attenuation was gained from the acquired cone-beam CT or the planning CT by calculating a water-equivalent radiological thickness for each irradiation direction. To verify the algorithm an inhomogeneous phantom consisting of three inhomogeneities was irradiated by a static 6 MV photon field and compared to a reference flood field image. Results: The mean deviation between the reconstructed relative photon fluence for the inhomogeneous phantom and the flood field EPID image was 3% rising up to 7% for off-axis fluence. This was probably caused by the used clinical EPID calibration, which flattens the inhomogeneous fluence profile of the beam. Conclusion: In this clinical experiment the algorithm achieved good results in the center of the field while it showed high deviation of the lateral fluence. This could be reduced by optimizing the EPID calibration, considering the off-axis differential energy response. In further progress this and other aspects of the EPID, eg. field size dependency, CT and dose calibration have to be studied to realize a clinical acceptable accuracy of 2%.« less
Stahl, Stephane; Hentschel, Pascal; Ketelsen, Dominik; Grosse, Ulrich; Held, Manuel; Wahler, Theodora; Syha, Roland; Schaller, Hans-Eberhard; Nikolaou, Konstantin; Grözinger, Gerd
2017-05-01
This prospective clinical study examined standard wrist magnetic resonance imaging (MRI) examinations and the incremental value of computed tomography (CT) in the diagnosis of Kienböck's disease (KD) with regard to reliability and precision in the different diagnostic steps during diagnostic work-up. Sixty-four consecutive patients referred between January 2009 and January 2014 with positive initial suspicion of KD according to external standard wrist MRI were prospectively included (step one). Institutional review board approval was obtained. Clinical examination by two handsurgeons were followed by wrist radiographs (step two), ultrathin-section CT, and 3T contrast-enhanced MRI (step three). Final diagnosis was established in a consensus conference involving all examiners and all examinations results available from step three. In 12/64 patients, initial suspicion was discarded at step two and in 34/64 patients, the initial suspicion of KD was finally discarded at step three. The final external MRI positive predictive value was 47%. The most common differential diagnoses at step three were intraosseous cysts (n=15), lunate pseudarthrosis (n=13), and ulnar impaction syndrome (n=5). A correlation between radiograph-based diagnoses (step two) with final diagnosis (step three) showed that initial suspicion of stage I KD had the lowest sensitivity for correct diagnosis (2/11). Technical factors associated with a false positive external MRI KD diagnosis were not found. Standard wrist MRI should be complemented with thin-section CT, and interdisciplinary interpretation of images and clinical data, to increase diagnostic accuracy in patients with suspected KD. Copyright © 2017. Published by Elsevier B.V.
The origins of SPECT and SPECT/CT.
Hutton, Brian F
2014-05-01
Single photon emission computed tomography (SPECT) has a long history of development since its initial demonstration by Kuhl and Edwards in 1963. Although clinical utility has been dominated by the rotating gamma camera, there have been many technological innovations with the recent popularity of organ-specific dedicated SPECT systems. The combination of SPECT and CT evolved from early transmission techniques used for attenuation correction with the initial commercial systems predating the release of PET/CT. The development and acceptance of SPECT/CT has been relatively slow with continuing debate as to what cost/performance ratio is justified. Increasingly, fully diagnostic CT is combined with SPECT so as to facilitate optimal clinical utility.
Proulx, Steven T.; Kwok, Edmund; You, Zhigang; Papuga, M. Owen; Beck, Christopher A.; Shealy, David J.; Ritchlin, Christopher T.; Awad, Hani A.; Boyce, Brendan F.; Xing, Lianping; Schwarz, Edward M.
2009-01-01
Objective Development of longitudinal 3D outcomes of inflammation and bone erosion in murine arthritis using contrast enhanced (CE) MRI and in vivo micro-CT; and in a pilot study, to determine the value of entrance criteria by age versus synovial volume in therapeutic intervention studies. Methods CE-MRI and in vivo micro-CT was performed on TNF-Tg and WT littermates to quantify the synovial and popliteal lymph node (LN) volumes and patella and talus bone volumes, respectively, which were validated with histology. These longitudinal outcome measures were used to assess the natural history of inflammatory-erosive arthritis. We also performed anti-TNF versus placebo efficacy studies in TNF-Tg mice in which treatment was initiated either by age (4–5 months) or synovial volume (3mm3 as detected by CE-MRI). Linear regression was performed to analyze the correlation between synovitis and focal erosion. Results CE-MRI demonstrated the highly variable nature of TNF-induced joint inflammation. Initiation of treatment by synovial volume produced significantly larger treatment effects on synovial volume (p=0.04) and lymph node volume (p<0.01) than initiation by age. By correlating the MRI and microCT data we were able to demonstrate a significant relationship between changes in synovial and patellar volumes (R2 =0.75; p<0.01). Conclusion In vivo CE-MRI and micro-CT 3D outcome measures are powerful tools that accurately demonstrate the progression of inflammatory-erosive arthritis in mice. These methods can be used to identify mice with arthritis of similar severity before intervention studies are initiated and thus minimize heterogeneity in outcome studies of chronic arthritis seen between genetically identical littermates. PMID:18050199
[Analysis of 163 rib fractures by imaging examination].
Song, Tian-fu; Wang, Chao-chao
2014-12-01
To explore the applications of imaging examination on rib fracture sites in forensic identification. Features including the sites, numbers of the processed imaging examination and the first radiological technology at diagnosis in 56 cases of rib fractures from 163 injuries were retrospectively analyzed. The detection rate of the rib fractures within 14 days was 65.6%. The initial detection rate of anterior rib fracture proceeded by X-ray was 76.2%, then 90.5% detected at a second time X-ray, while the detection rate of CT was 66.7% and 80.0%, respectively. The initial detec- tion rate of rib fracture in axillary section proceeded by X-ray was 27.6%, then 58.6% detected at a second time X-ray, while the detection rate of CT was 54.3% and 80.4%, respectively. The initial detection rate of posterior rib fracture proceeded by X-ray was 63.6%, then 81.8% detected at a second time X-ray, while the detection rate of CT was 50.0% and 70.0%, respectively. It is important to pay attention to the use of combined imaging examinations and the follow-up results. In the cases of suspicious for rib fracture in axillary section, CT examination is suggested in such false X-ray negative cases.
Gao, Yaozong; Shao, Yeqin; Lian, Jun; Wang, Andrew Z.; Chen, Ronald C.
2016-01-01
Segmenting male pelvic organs from CT images is a prerequisite for prostate cancer radiotherapy. The efficacy of radiation treatment highly depends on segmentation accuracy. However, accurate segmentation of male pelvic organs is challenging due to low tissue contrast of CT images, as well as large variations of shape and appearance of the pelvic organs. Among existing segmentation methods, deformable models are the most popular, as shape prior can be easily incorporated to regularize the segmentation. Nonetheless, the sensitivity to initialization often limits their performance, especially for segmenting organs with large shape variations. In this paper, we propose a novel approach to guide deformable models, thus making them robust against arbitrary initializations. Specifically, we learn a displacement regressor, which predicts 3D displacement from any image voxel to the target organ boundary based on the local patch appearance. This regressor provides a nonlocal external force for each vertex of deformable model, thus overcoming the initialization problem suffered by the traditional deformable models. To learn a reliable displacement regressor, two strategies are particularly proposed. 1) A multi-task random forest is proposed to learn the displacement regressor jointly with the organ classifier; 2) an auto-context model is used to iteratively enforce structural information during voxel-wise prediction. Extensive experiments on 313 planning CT scans of 313 patients show that our method achieves better results than alternative classification or regression based methods, and also several other existing methods in CT pelvic organ segmentation. PMID:26800531
Bazarian, Jeffrey J; Beck, Christopher; Blyth, Brian; von Ahsen, Nicolas; Hasselblatt, Martin
2006-01-01
To validate a correction factor for the extracranial release of the astroglial protein, S-100B, based on concomitant creatine kinase (CK) levels. The CK- S-100B relationship in non-head injured marathon runners was used to derive a correction factor for the extracranial release of S-100B. This factor was then applied to a separate cohort of 96 mild traumatic brain injury (TBI) patients in whom both CK and S-100B levels were measured. Corrected S-100B was compared to uncorrected S-100B for the prediction of initial head CT, three-month headache and three-month post concussive syndrome (PCS). Corrected S-100B resulted in a statistically significant improvement in the prediction of 3-month headache (area under curve [AUC] 0.46 vs 0.52, p=0.02), but not PCS or initial head CT. Using a cutoff that maximizes sensitivity (> or = 90%), corrected S-100B improved the prediction of initial head CT scan (negative predictive value from 75% [95% CI, 2.6%, 67.0%] to 96% [95% CI: 83.5%, 99.8%]). Although S-100B is overall poorly predictive of outcome, a correction factor using CK is a valid means of accounting for extracranial release. By increasing the proportion of mild TBI patients correctly categorized as low risk for abnormal head CT, CK-corrected S100-B can further reduce the number of unnecessary brain CT scans performed after this injury.
GAUGING THE EXTENT OF THYROIDECTOMY FOR INDETERMINATE THYROID NODULES: AN ONCOLOGIC PERSPECTIVE.
Schneider, David F; Cherney Stafford, Linda M; Brys, Nicole; Greenberg, Caprice C; Balentine, Courtney J; Elfenbein, Dawn M; Pitt, Susan C
2017-04-02
Increasing emphasis is being placed on appropriateness of care and avoidance of over- and under-treatment. Indeterminate thyroid nodules (ITNs) present a particular risk for this problem because cancer found via diagnostic lobectomy (DL) often requires a completion thyroidectomy (CT). However, initial total thyroidectomy (TT) for benign ITN results in lifelong thyroid hormone replacement. We sought to measure the accuracy and factors associated with the extent of initial thyroidectomy for ITN. We queried a single institution thyroid surgery database for all adult patients undergoing an initial operation for ITN. Multivariate logistic regression identified factors associated with either oncologic under- or overtreatment at initial operation. There were 639 patients with ITN. The median age was 52 (range, 18 to 93) years, 78.4% were female, and final pathology revealed a cancer >1 cm in 24.7%. The most common cytology was follicular neoplasm (45.1%) followed by Hürthle cell neoplasm (20.2%). CT or initial oncologic undertreatment was required in 58 patients (9.3%). Excluding those with goiters, 19.0% were treated with TT for benign final pathology. Multivariate analysis failed to identify any factor that independently predicted the need for CT. Female gender was associated with TT in benign disease (odds ratio [OR], 2.1; 95% confidence interval [CI], 1.0 to 4.5; P = .05). Age >45 years predicted correct initial use of DL (OR, 2.6; 95% CI, 1.2 to 5.7; P = .02). Suspicious for papillary thyroid carcinoma (OR, 5.7; 95% CI, 2.1 to 15.3; P<.01) and frozen section (OR, 9.7; 95% CI, 2.5 to 38.6; P<.01) were associated with oncologically appropriate initial TT. The highest frequency of CT occurred in patients with follicular lesion of undetermined significance (11.6%). TT for benign final pathology occurred most frequently in patients with a Hürthle cell neoplasm (24.8%). In patients with ITN, nearly 30% received an inappropriate extent of initial thyroidectomy from an oncologic standpoint. Tools to pre-operatively identify both benign and malignant disease can assist in the complex decision making to gauge the proper extent of initial surgery for ITN. ATA = American Thyroid Association AUS = atypia of undetermined significance CI = confidence interval CT = completion thyroidectomy FLUS = follicular lesion of undetermined significance ITN = indeterminate thyroid nodule OR = odds ratio PTC = papillary thyroid carcinoma TT = total thyroidectomy.
Evaluation of a new imaging tool for use with major trauma cases in the emergency department.
Crönlein, Moritz; Holzapfel, Konstantin; Beirer, Marc; Postl, Lukas; Kanz, Karl-Georg; Pförringer, Dominik; Huber-Wagner, Stefan; Biberthaler, Peter; Kirchhoff, Chlodwig
2016-11-17
The aim of this study was to evaluate potential benefits of a new diagnostic software prototype (Trauma Viewer, TV) automatically reformatting computed tomography (CT) data on diagnostic speed and quality, compared to CT-image data evaluation using a conventional CT console. Multiple trauma CT data sets were analysed by one expert radiology and one expert traumatology fellow independently twice, once using the TV and once using the secondary conventional CT console placed in the CT control room. Actual analysis time and precision of diagnoses assessment were evaluated. The TV and CT-console results were compared respectively, but also a comparison to the initial multiple trauma CT reports assessed by emergency radiology fellows considered as the gold standard was performed. Finally, design and function of the Trauma Viewer were evaluated in a descriptive manner. CT data sets of 30 multiple trauma patients were enrolled. Mean time needed for analysis of one CT dataset was 2.43 min using the CT console and 3.58 min using the TV respectively. Thus, secondary conventional CT console analysis was on average 1.15 min shorter compared to the TV analysis. Both readers missed a total of 11 diagnoses using the secondary conventional CT console compared to 12 missed diagnoses using the TV. However, none of these overlooked diagnoses resulted in an Abbreviated Injury Scale (AIS) > 2 corresponding to life threatening injuries. Even though it took the two expert fellows a little longer to analyse the CT scans on the prototype TV compared to the CT console, which can be explained by the new user interface of the TV, our preliminary results demonstrate that, after further development, the TV might serve as a new diagnostic feature in the trauma room management. Its high potential to improve time and quality of CT-based diagnoses might help in fast decision making regarding treatment of severely injured patients.
Automatic segmentation of the prostate on CT images using deep learning and multi-atlas fusion
NASA Astrophysics Data System (ADS)
Ma, Ling; Guo, Rongrong; Zhang, Guoyi; Tade, Funmilayo; Schuster, David M.; Nieh, Peter; Master, Viraj; Fei, Baowei
2017-02-01
Automatic segmentation of the prostate on CT images has many applications in prostate cancer diagnosis and therapy. However, prostate CT image segmentation is challenging because of the low contrast of soft tissue on CT images. In this paper, we propose an automatic segmentation method by combining a deep learning method and multi-atlas refinement. First, instead of segmenting the whole image, we extract the region of interesting (ROI) to delete irrelevant regions. Then, we use the convolutional neural networks (CNN) to learn the deep features for distinguishing the prostate pixels from the non-prostate pixels in order to obtain the preliminary segmentation results. CNN can automatically learn the deep features adapting to the data, which are different from some handcrafted features. Finally, we select some similar atlases to refine the initial segmentation results. The proposed method has been evaluated on a dataset of 92 prostate CT images. Experimental results show that our method achieved a Dice similarity coefficient of 86.80% as compared to the manual segmentation. The deep learning based method can provide a useful tool for automatic segmentation of the prostate on CT images and thus can have a variety of clinical applications.
Chakraborty, Amit; von Herrmann, Paul F; Embertson, Ryan E; Landwehr, Kevin P; Winkler, Michael A
2016-01-01
A case of a tornado victim with a delayed presentation of injury to the aortic isthmus is discussed. Tornado forces resemble the forces of high energy explosions, and the injuries that can occur as a result of these forces can be bizarre. The patient presented with the unique computed tomography (CT) findings of isolated pseudoaneurysm of the thoracic aorta in the absence of other traumatic injury to the thorax. Equivocal results of the initial CT aortogram (CTA) were confirmed with ECG-synchronized CTA (ECG-CTA), demonstrating the superiority of ECG-CTA as compared to standard CTA. Copyright © 2016 Elsevier Inc. All rights reserved.
Wu, Guofeng; Shen, Zhengkui; Wang, Likun; Sun, Shujie; Luo, Jinbiao; Mao, Yuanhong
2017-07-06
Intracranial post-operative re-haemorrhage is an important complication in patients with hypertensive intracerebral haemorrhage (ICH). The purpose of the present study was to determine the value of the computed tomography (CT) blend sign in predicting post-operative re-haemorrhage in patients with ICH. A total of 126 patients with ICH were included in the present study. All the patients underwent standard stereotactic minimally invasive surgery(MIS) to remove the ICH within 24 h following admission. There were 41 patients with a blend sign on initial CT and 85 patients without a blend sign on the initial CT. Multivariable logistic regression analyses were performed to assess the relationship between the presence of the blend sign on the non-enhanced admission CT scan and post-operative re-haemorrhage. Post-operative re-haemorrhage occurred in 24 of the 41 patients with the blend sign, and in 9 of the 85 patients without the blend sign. The incidence of re-haemorrhage was significantly different between the groups. The multivariate logistic regression analysis demonstrated that the initial Glasgow coma scale score (p = 0.002) and blend sign (P < 0.00) on the initial CT scan are independent predictors of post-operative re-haemorrhage. The sensitivity, specificity, and positive and negative predictive values of the blend sign for predicting post-operative re-haemorrhage were 72.7, 81.7, 58.5 and 89.4%, respectively. The presence of the blend sign on the initial CT scan is closely associated with post-operative re-haemorrhage in patients with ICH who undergo stereotactic MIS.
Sterzing, Florian; Kratochwil, Clemens; Fiedler, Hannah; Katayama, Sonja; Habl, Gregor; Kopka, Klaus; Afshar-Oromieh, Ali; Debus, Jürgen; Haberkorn, Uwe; Giesel, Frederik L
2016-01-01
Radiotherapy is the main therapeutic approach besides surgery of localized prostate cancer. It relies on risk stratification and exact staging. This report analyses the potential of [(68)Ga]Glu-urea-Lys(Ahx)-HBED-CC ((68)Ga-PSMA-11), a new positron emission tomography (PET) tracer targeting prostate-specific membrane antigen (PSMA) for prostate cancer staging and individualized radiotherapy planning. A cohort of 57 patients with prostate cancer scanned with (68)Ga-PSMA-11 PET/CT for radiotherapy planning was retrospectively reviewed; 15 patients were at initial diagnosis and 42 patients at time of biochemical recurrence. Staging results of conventional imaging, including bone scintigraphy, CT or MRI, were compared with (68)Ga-PSMA ligand PET/CT results and the influence on radiotherapeutic management was quantified. (68)Ga-PSMA ligand PET/CT had a dramatic impact on radiotherapy application in the presented cohort. In 50.8 % of the cases therapy was changed. The presented imaging technique of (68)Ga-PSMA PET/CT could be a key technology for individualized radiotherapy management in prostate cancer.
Use of the initial trauma CT scan to aid in diagnosis of open pelvic fractures.
Scolaro, John A; Wilson, David J; Routt, Milton Lee Chip; Firoozabadi, Reza
2015-10-01
Open pelvic disruptions represent high-energy injuries. The prompt identification and management of these injuries decreases their associated morbidity and mortality. Computed tomography (CT) scans are routinely obtained in the initial evaluation of patients with pelvic injuries. The purpose of this study is to identify the incidence and source of air densities noted on computed tomography (CT) scans of the abdominal and pelvic region in patients with pelvic fractures and evaluate the use of initial CT imaging as an adjunctive diagnostic tool to identify open injuries. A retrospective review of a prospectively collected database was performed at a single institution. Seven hundred and twenty-two consecutive patients with a pelvic disruption over a two-year period were included. Review of initial injury CT scans was performed using bone and lung viewing algorithms to identify the presence of extra-luminal air. The primary outcome was the presence, location and source of air identified on pre-operative CT scans. Secondary measurements were identification of air by plain radiograph and correlation between identified air densities on CT and clinically diagnosed open pelvic fractures. Ninety-eight patients were identified as having extra-luminal air densities on CT scans. Eighty-one patients were included in the final analysis following application of inclusion and exclusion criteria. Air was noted by the radiologist in forty-five (55.6%) instances. Six patients (7.4%) were clinically diagnosed with an open pelvic ring disruption; in two patients (2.4%) this diagnosis was delayed. In all patients, the CT was able to track air from its origin. In patients with pelvic disruptions, the injury CT should also be evaluated for the presence and source of extra-luminal air. In some patients, this finding may represent an open pelvic ring disruption. A complete physical exam and CT evaluation should be used to decrease the missed or delayed diagnosis of an open pelvic ring injury. Copyright © 2015 Elsevier Ltd. All rights reserved.
Lung cancer mimicking lung abscess formation on CT images.
Taira, Naohiro; Kawabata, Tsutomu; Gabe, Atsushi; Ichi, Takaharu; Kushi, Kazuaki; Yohena, Tomofumi; Kawasaki, Hidenori; Yamashiro, Toshimitsu; Ishikawa, Kiyoshi
2014-01-01
Male, 64 FINAL DIAGNOSIS: Lung pleomorphic carcinoma Symptoms: Cough • fever - Clinical Procedure: - Specialty: Oncology. Unusual clinical course. The diagnosis of lung cancer is often made based on computed tomography (CT) image findings if it cannot be confirmed on pathological examinations, such as bronchoscopy. However, the CT image findings of cancerous lesions are similar to those of abscesses.We herein report a case of lung cancer that resembled a lung abscess on CT. We herein describe the case of 64-year-old male who was diagnosed with lung cancer using surgery. In this case, it was quite difficult to distinguish between the lung cancer and a lung abscess on CT images, and a lung abscess was initially suspected due to symptoms, such as fever and coughing, contrast-enhanced CT image findings showing a ring-enhancing mass in the right upper lobe and the patient's laboratory test results. However, a pathological diagnosis of lung cancer was confirmed according to the results of a rapid frozen section biopsy of the lesion. This case suggests that physicians should not suspect both a lung abscesses and malignancy in cases involving masses presenting as ring-enhancing lesions on contrast-enhanced CT.
Conde-Moreno, A J; Herrando-Parreño, G; Muelas-Soria, R; Ferrer-Rebolleda, J; Broseta-Torres, R; Cozar-Santiago, M P; García-Piñón, F; Ferrer-Albiach, C
2017-05-01
To determine the effectiveness of whole-body diffusion-weighted magnetic resonance imaging (WB-DW-MRI) in detecting metastases by comparing the results with those from choline-positron emission tomography-computed tomography (choline-PET/CT) in patients with biochemical relapse after primary treatment, and no metastases in bone scintigraphy, CT and/or pelvic MRI, or metastatic/oligometastatic prostate cancer (PCa). Patients with this disease profile who could benefit from treatment with stereotactic body radiation therapy (SBRT) were selected and their responses to these techniques were rated. This was a prospective, controlled, unicentric study, involving 46 consecutive patients from our centre who presented biochemical relapse after adjuvant, salvage or radical treatment with external beam radiotherapy, or brachytherapy. After initial tests (bone scintigraphy, CT, pelvic MRI), 35 patients with oligometastases or without them were selected. 11 patients with multiple metastases were excluded from the study. WB-DW-MRI and choline-PET/CT was then performed on each patient within 1 week. The results were interpreted by specialists in nuclear medicine and MRI. If they were candidates for treatment with ablative SBRT (SABR), they were then evaluated every three months with both tests. Choline-PET/CT detected lesions in 16 patients that were not observable using WB-DW-MRI. The results were consistent in seven patients and in three cases, a lesion was observed using WB-DW-MRI that was not detected with choline-PET/CT. The Kappa value obtained was 0.133 (p = 0.089); the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of WB-DW-MRI were estimated at 44.93, 64.29, 86.11, and 19.15%, respectively. For choline-PET/CT patients, the sensitivity, specificity, PPV, and NPV were 97.10, 58.33, 93.06, and 77.78%, respectively. Choline-PET/CT has a high global sensitivity while WB-DW-MRI has a high specificity, and so they are complementary techniques. Future studies with more enrolled patients and a longer follow-up period will be required to confirm these data. The initial data show that the best technique for evaluating response after SBRT is choline-PET/CT. Trial registration number NCT02858128.
Cortés Romera, M; Gámez Cenzano, C; Caresia Aróztegui, A P; Martín-Comín, J; González-Barca, E; Ricart Brulles, Y; Palacios Abufón, A; Robles Barba, J; Rodríguez-Bel, L; Rossi Seoane, S; Fernández de Sevilla, A
2012-01-01
To assess the role of FDG-PET/CT performed after the first cycles of chemotherapy in the prediction of response to treatment in patients with diffuse large B-cell lymphoma. Twenty patients (mean age: 48 years) were included, 16 initial staging and 4 relapse. All patients underwent PET/CT at 3 times: 1) Baseline, 2) After 1-3 cycles of chemotherapy (early response assessment), and 3) End of treatment (evaluation of final response). Early PET/CT findings were correlated to the end-treatment PET/CT and follow-up. The evaluation of the response was established according to the decrease in uptake of the lesions (SUVmax). In the early assessment, a good response indicator (GRI) was obtained when the lesion disappeared or had more than 50% reduction in SUVmax. At the end of the treatment, a complete metabolic response (CMR) was determined in negative PET scans. Follow-up was superior to 19 months and final outcome was established as progression/relapse or no evidence of disease (NED). At the early treatment evaluation, 16/16 patients of initial staging (100%) and 2/4 of relapse (50%) achieved GRI. At the end of treatment evaluation, 14/16 patients of initial staging with GRI achieved CMR and 1/16 PMR: 14 were alive with NED in the follow-up while 1 relapsed. In the second group, 2/2 patients with GRI achieved CMR (100%): 1 continued with NED in the follow-up and another relapsed. FDG-PET/CT after the first cycles of chemotherapy is useful to monitor treatment due to its high negative predictive value (87.5%), using it to modify treatment early in the non-responders. Copyright © 2011 Elsevier España, S.L. y SEMNIM. All rights reserved.
Criteria for CT and Initial Management of Head Injured Infants: A Review
SHIOMI, Naoto; ECHIGO, Tadashi; HINO, Akihiko; HASHIMOTO, Naoya; YAMAKI, Tarumi
2016-01-01
Criteria for computed tomography (CT) to head injured infants have not been established. Since the identification of neurological findings is difficult in infants, examination by CT may be necessary in some cases, but it may be difficult to perform CT because of problems with radiation exposure and body movement. Moreover, even though no intracranial abnormality was found immediately after injury, abnormal findings may appear after several hours. From this viewpoint, course observation after injury may be more important than CT in the initial treatment of head trauma in infants. The complaints and neurological manifestations of infants, particularly those aged 2 or younger, are frequently unclear; therefore, there is an opinion that CT is recommended for all pediatric patients. However, the appropriateness of its use should be determined after confirming the mechanism of injury, consciousness level, neurological findings, and presence/absence of a history of abuse. Among the currently available rules specifying criteria for CT of infants with head trauma, the Pediatric Emergency Care Applied Research Network (PECARN) study may be regarded as reliable at present. In Japan, where the majority of emergency hospitals are using CT, it may be necessary to develop criteria for CT in consideration of the actual situation. CT diagnosis for pediatric head trauma is not always necessary. When no imaging is performed, this should be fully explained at the initial treatment before selecting course observation at home. Checking on a state of the patients by telephone is useful for both patients and physicians. PMID:27194179
Lung cancer perfusion: can we measure pulmonary and bronchial circulation simultaneously?
Yuan, Xiaodong; Zhang, Jing; Ao, Guokun; Quan, Changbin; Tian, Yuan; Li, Hong
2012-08-01
To describe a new CT perfusion technique for assessing the dual blood supply in lung cancer and present the initial results. This study was approved by the institutional review board. A CT protocol was developed, and a dual-input CT perfusion (DI-CTP) analysis model was applied and evaluated regarding the blood flow fractions in lung tumours. The pulmonary trunk and the descending aorta were selected as the input arteries for the pulmonary circulation and the bronchial circulation respectively. Pulmonary flow (PF), bronchial flow (BF), and a perfusion index (PI, = PF/ (PF + BF)) were calculated using the maximum slope method. After written informed consent was obtained, 13 consecutive subjects with primary lung cancer underwent DI-CTP. Perfusion results are as follows: PF, 13.45 ± 10.97 ml/min/100 ml; BF, 48.67 ± 28.87 ml/min/100 ml; PI, 21 % ± 11 %. BF is significantly larger than PF, P < 0.001. There is a negative correlation between the tumour volume and perfusion index (r = 0.671, P = 0.012). The dual-input CT perfusion analysis method can be applied successfully to lung tumours. Initial results demonstrate a dual blood supply in primary lung cancer, in which the systemic circulation is dominant, and that the proportion of the two circulation systems is moderately dependent on tumour size. A new CT perfusion technique can assess lung cancer's dual blood supply. A dual blood supply was confirmed with dominant bronchial circulation in lung cancer. The proportion of the two circulations is moderately dependent on tumour size. This new technique may benefit the management of lung cancer.
Lee, Jeong Woo; Kim, Ho Gak; Lee, Dong Wook; Han, Jimin; Kwon, Hyuk Yong; Seo, Chang Jin; Oh, Ji Hye; Lee, Joo Hyoung; Jung, Jin Tae; Kwon, Joong Goo; Kim, Eun Young
2016-01-01
Background/Aims Smoking and alcohol intake are two well-known risk factors for chronic pancreatitis. However, there are few studies examining the association between smoking and changes in computed tomography (CT) findings in chronic pancreatitis. The authors evaluated associations between smoking, drinking and the progression of calcification on CT in chronic pancreatitis. Methods In this retrospective study, 59 patients with chronic pancreatitis who had undergone initial and follow-up CT between January 2002 and September 2010 were included. Progression of calcification among CT findings was compared according to the amount of alcohol intake and smoking. Results The median duration of follow-up was 51.6 months (range, 17.1 to 112.7 months). At initial CT findings, there was pancreatic calcification in 35 patients (59.3%). In the follow-up CT, progression of calcification was observed in 37 patients (62.7%). Progression of calcification was more common in smokers according to the multivariate analysis (odds ratio [OR], 9.987; p=0.006). The amount of smoking was a significant predictor for progression of calcification in the multivariate analysis (OR, 6.051 in less than 1 pack per day smokers; OR, 36.562 in more than 1 pack per day smokers; p=0.008). Conclusions Continued smoking accelerates pancreatic calcification, and the amount of smoking is associated with the progression of calcification in chronic pancreatitis. PMID:26601825
Assessment of the effects of CT dose in averaged x-ray CT images of a dose-sensitive polymer gel
NASA Astrophysics Data System (ADS)
Kairn, T.; Kakakhel, M. B.; Johnston, H.; Jirasek, A.; Trapp, J. V.
2015-01-01
The signal-to-noise ratio achievable in x-ray computed tomography (CT) images of polymer gels can be increased by averaging over multiple scans of each sample. However, repeated scanning delivers a small additional dose to the gel which may compromise the accuracy of the dose measurement. In this study, a NIPAM-based polymer gel was irradiated and then CT scanned 25 times, with the resulting data used to derive an averaged image and a "zero-scan" image of the gel. Comparison between these two results and the first scan of the gel showed that the averaged and zero-scan images provided better contrast, higher contrast-to- noise and higher signal-to-noise than the initial scan. The pixel values (Hounsfield units, HU) in the averaged image were not noticeably elevated, compared to the zero-scan result and the gradients used in the linear extrapolation of the zero-scan images were small and symmetrically distributed around zero. These results indicate that the averaged image was not artificially lightened by the small, additional dose delivered during CT scanning. This work demonstrates the broader usefulness of the zero-scan method as a means to verify the dosimetric accuracy of gel images derived from averaged x-ray CT data.
Zhu, Liangjia; Gao, Yi; Appia, Vikram; Yezzi, Anthony; Arepalli, Chesnal; Faber, Tracy; Stillman, Arthur; Tannenbaum, Allen
2014-01-01
The left ventricular myocardium plays a key role in the entire circulation system and an automatic delineation of the myocardium is a prerequisite for most of the subsequent functional analysis. In this paper, we present a complete system for an automatic segmentation of the left ventricular myocardium from cardiac computed tomography (CT) images using the shape information from images to be segmented. The system follows a coarse-to-fine strategy by first localizing the left ventricle and then deforming the myocardial surfaces of the left ventricle to refine the segmentation. In particular, the blood pool of a CT image is extracted and represented as a triangulated surface. Then, the left ventricle is localized as a salient component on this surface using geometric and anatomical characteristics. After that, the myocardial surfaces are initialized from the localization result and evolved by applying forces from the image intensities with a constraint based on the initial myocardial surface locations. The proposed framework has been validated on 34-human and 12-pig CT images, and the robustness and accuracy are demonstrated. PMID:24723531
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-01
... announced below concerns Low Dose CT Lung Cancer Screening: Informed Decision Making and Smoking Cessation... include the initial review, discussion, and evaluation of ``Low Dose CT Lung Cancer Screening: Informed...
Magnetic resonance force microscopy with a paramagnetic probe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berman, G. P.; Gorshkov, V. N.; Tsifrinovich, V. I.
Here, we consider theoretically extension of magnetic resonance force microscopy (MRFM) replacing a ferromagnetic probe on a cantilever tip (CT) with a paramagnetic one (PMRFM). The dynamics of the interaction between the paramagnetic probe and a local magnetic moment in a sample is analyzed, using a quasi-classical approach. We show that the application of a proper sequence of electromagnetic pulses provides a significant deflection of the CT from the initial equilibrium position. Periodic application of these sequences of pulses results in quasi-periodic CT deflections from the equilibrium, which can be used for detection of the magnetic moment in a sample.
Magnetic resonance force microscopy with a paramagnetic probe
NASA Astrophysics Data System (ADS)
Berman, G. P.; Gorshkov, V. N.; Tsifrinovich, V. I.
2017-04-01
We consider theoretically extension of magnetic resonance force microscopy (MRFM) replacing a ferromagnetic probe on a cantilever tip (CT) with a paramagnetic one (PMRFM). The dynamics of the interaction between the paramagnetic probe and a local magnetic moment in a sample is analyzed, using a quasi-classical approach. We show that the application of a proper sequence of electromagnetic pulses provides a significant deflection of the CT from the initial equilibrium position. Periodic application of these sequences of pulses results in quasi-periodic CT deflections from the equilibrium, which can be used for detection of the magnetic moment in a sample.
Magnetic resonance force microscopy with a paramagnetic probe
Berman, G. P.; Gorshkov, V. N.; Tsifrinovich, V. I.
2017-04-01
Here, we consider theoretically extension of magnetic resonance force microscopy (MRFM) replacing a ferromagnetic probe on a cantilever tip (CT) with a paramagnetic one (PMRFM). The dynamics of the interaction between the paramagnetic probe and a local magnetic moment in a sample is analyzed, using a quasi-classical approach. We show that the application of a proper sequence of electromagnetic pulses provides a significant deflection of the CT from the initial equilibrium position. Periodic application of these sequences of pulses results in quasi-periodic CT deflections from the equilibrium, which can be used for detection of the magnetic moment in a sample.
Rui, Y; Han, M; Zhou, W; He, Q; Li, H; Li, P; Zhang, F; Shi, Y; Su, X
2018-06-06
To determine true negatives and characterise the variables associated with false-negative results when interpreting non-malignant results of computed tomography (CT)-guided lung biopsy. Nine hundred and fifty patients with initial non-malignant findings on their first transthoracic CT-guided core-needle biopsy (TTNB) were included in the study. Initial biopsy results were compared to definitive diagnoses established later. The negative predictive value (NPV) of non-malignant diseases upon initial TTNB was 83.6%. When the biopsy results indicated specific infection or benign tumour (n=225, 26.1%), they all were confirmed true negative for malignancy later. Only one inconclusive "granuloma" diagnosis was false negative. All 141 patients (141/861, 16.4%) who were false negative for malignancy were from the "infection not otherwise specified (NOS)", "inflammatory diseases", or "inconclusive" groups. Age (p=0.002), cancer history (p<0.001), target size (p=0.003), and pneumothorax during lung biopsy (p=0.003) were found to be significant predictors of false-negative results; 47.6% (410/861) of patients underwent additional invasive examinations to reach a final diagnosis. Ultimately, 52.7% (216/410) were successfully diagnosed. Specific infection, benign tumour, and granulomatous inflammation of first TTNBs were mostly true negative. Older age, history of cancer, larger target size, and pneumothorax were highly predictive of false-negative results for malignancies. In such cases, additional invasive examinations were frequently necessary to obtain final diagnoses. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Nia, Emily S; Garland, Linda L; Eshghi, Naghmehossadat; Nia, Benjamin B; Avery, Ryan J; Kuo, Phillip H
2017-09-01
The brain is the most common site of distant metastasis from lung cancer. Thus, MRI of the brain at initial staging is routinely performed, but if this examination is negative a follow-up examination is often not performed. This study evaluates the incidence of asymptomatic brain metastases in non-small cell lung cancer patients detected on follow-up 18 F-FDG PET/CT scans. Methods: In this Institutional Review Board-approved retrospective review, all vertex to thigh 18 F-FDG PET/CT scans in patients with all subtypes of lung cancer from August 2014 to August 2016 were reviewed. A total of 1,175 18 F-FDG PET/CT examinations in 363 patients were reviewed. Exclusion criteria included brain metastases on initial staging, histologic subtype of small-cell lung cancer, and no follow-up 18 F-FDG PET/CT examinations. After our exclusion criteria were applied, a total of 809 follow-up 18 F-FDG PET/CT scans in 227 patients were included in the final analysis. The original report of each 18 F-FDG PET/CT study was reviewed for the finding of brain metastasis. The finding of a new brain metastasis prompted a brain MRI, which was reviewed to determine the accuracy of the 18 F-FDG PET/CT. Results: Five of 227 patients with 809 follow-up 18 F-FDG PET/CT scans reviewed were found to have incidental brain metastases. The mean age of the patients with incidental brain metastasis was 68 y (range, 60-77 y). The mean time from initial diagnosis to time of detection of incidental brain metastasis was 36 mo (range, 15-66 mo). When MRI was used as the gold standard, our false-positive rate was zero. Conclusion: By including the entire head during follow-up 18 F-FDG PET/CT scans of patients with non-small cell lung cancer, brain metastases can be detected earlier while still asymptomatic. But, given the additional scan time, radiation, and low incidence of new brain metastases in asymptomatic patients, the cost-to-benefit ratio should be weighed by each institution. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Attenuation-emission alignment in cardiac PET∕CT based on consistency conditions
Alessio, Adam M.; Kinahan, Paul E.; Champley, Kyle M.; Caldwell, James H.
2010-01-01
Purpose: In cardiac PET and PET∕CT imaging, misaligned transmission and emission images are a common problem due to respiratory and cardiac motion. This misalignment leads to erroneous attenuation correction and can cause errors in perfusion mapping and quantification. This study develops and tests a method for automated alignment of attenuation and emission data. Methods: The CT-based attenuation map is iteratively transformed until the attenuation corrected emission data minimize an objective function based on the Radon consistency conditions. The alignment process is derived from previous work by Welch et al. [“Attenuation correction in PET using consistency information,” IEEE Trans. Nucl. Sci. 45, 3134–3141 (1998)] for stand-alone PET imaging. The process was evaluated with the simulated data and measured patient data from multiple cardiac ammonia PET∕CT exams. The alignment procedure was applied to simulations of five different noise levels with three different initial attenuation maps. For the measured patient data, the alignment procedure was applied to eight attenuation-emission combinations with initially acceptable alignment and eight combinations with unacceptable alignment. The initially acceptable alignment studies were forced out of alignment a known amount and quantitatively evaluated for alignment and perfusion accuracy. The initially unacceptable studies were compared to the proposed aligned images in a blinded side-by-side review. Results: The proposed automatic alignment procedure reduced errors in the simulated data and iteratively approaches global minimum solutions with the patient data. In simulations, the alignment procedure reduced the root mean square error to less than 5 mm and reduces the axial translation error to less than 1 mm. In patient studies, the procedure reduced the translation error by >50% and resolved perfusion artifacts after a known misalignment for the eight initially acceptable patient combinations. The side-by-side review of the proposed aligned attenuation-emission maps and initially misaligned attenuation-emission maps revealed that reviewers preferred the proposed aligned maps in all cases, except one inconclusive case. Conclusions: The proposed alignment procedure offers an automatic method to reduce attenuation correction artifacts in cardiac PET∕CT and provides a viable supplement to subjective manual realignment tools. PMID:20384256
Sethia, Rishabh; Mahida, Justin B; Subbarayan, Rahul A; Deans, Katherine J; Minneci, Peter C; Elmaraghy, Charles A; Essig, Garth F
2017-05-01
To determine the clinical impact of an initiative to use ultrasound (US) as the primary diagnostic modality for children with superficial face and neck infections versus use of computed tomography (CT). Children with a diagnosis of lymphadenitis, face or neck abscess, or face and neck cellulitis were retrospectively evaluated by the otolaryngology service. Patients were separated into two groups based on implementation of a departmental initiative to use US as the primary diagnostic modality. The pre-implementation cohort consisted of patients treated prior to the initiative (2006-2009) and the current protocol cohort consisted of patients treated after the initiative was started (2010-2013). Demographics, use of US or CT, necessity of surgical intervention, and failure of medical management were compared. Three hundred seventy three children were evaluated; 114 patients were included in the pre-implementation cohort and 259 patients were included in the current protocol cohort for comparison. Patients presenting during the current protocol period were more likely to undergo US (pre-implementation vs. current protocol, p-value) (12% vs. 49%, p < 0.0001) and less likely to undergo CT (66% vs. 41%, p < 0.0001) for their initial evaluation. There were no differences in the percentage of children who underwent prompt surgical drainage, prompt discharge without surgery, or trial inpatient observation. There were also no differences in the rate of treatment failure for patients undergoing prompt surgery or prompt discharge on antibiotics. For those patients who underwent repeat evaluation following trial medical management, US was used more frequently in the current protocol period (4% vs. 20%, p = 0.002) with no difference in CT use, selected treatment strategy, or treatment failure rates. Increased use of US on initial evaluation of children with superficial face and neck infections resulted in decreased CT utilization, without negatively impacting outcome. Decreasing pediatric radiation exposure and potential long-term effects is of primary importance. Copyright © 2017. Published by Elsevier B.V.
Kea, Bory; Gamarallage, Ruwan; Vairamuthu, Hemamalini; Fortman, Jonathan; Lunney, Kevin; Hendey, Gregory W; Rodriguez, Robert M
2013-08-01
Computed tomography (CT) has been shown to detect more injuries than plain radiography in patients with blunt trauma, but it is unclear whether these injuries are clinically significant. This study aimed to determine the proportion of patients with normal chest x-ray (CXR) result and injury seen on CT and abnormal initial CXR result and no injury on CT and to characterize the clinical significance of injuries seen on CT as determined by a trauma expert panel. Patients with blunt trauma older than 14 years who received emergency department chest imaging as part of their evaluation at 2 urban level I trauma centers were enrolled. An expert trauma panel a priori classified thoracic injuries and subsequent interventions as major, minor, or no clinical significance. Of 3639 participants, 2848 (78.3%) had CXR alone and 791 (21.7%) had CXR and chest CT. Of 589 patients who had chest CT after a normal CXR result, 483 (82.0% [95% confidence interval [CI], 78.7-84.9%]) had normal CT results, and 106 (18.0% [95% CI, 15.1%-21.3%]) had CTs diagnosing injuries-primarily rib fractures, pulmonary contusion, and incidental pneumothorax. Twelve patients had injuries classified as clinically major (2.0% [95% CI, 1.2%-3.5%]), 78 were clinically minor (13.2% [95% CI, 10.7%-16.2%]), and 16 were clinically insignificant (2.7% (95% CI, 1.7%-4.4%]). Of 202 patients with CXRs suggesting injury, 177 (87.6% [95% CI, 82.4%-91.5%]) had chest CTs confirming injury and 25 (12.4% [95% CI, 8.5%-17.6%]) had no injury on CT. Chest CT after a normal CXR result in patients with blunt trauma detects injuries, but most do not lead to changes in patient management. Copyright © 2013 Elsevier Inc. All rights reserved.
Performance of FDG PET/CT in the clinical management of breast cancer.
Groheux, David; Espié, Marc; Giacchetti, Sylvie; Hindié, Elif
2013-02-01
In this analysis, the role of metabolic imaging with fluorine 18 fluorodeoxyglucose (FDG) in breast cancer is reviewed. The analysis was limited to recent works by using state-of-the-art positron emission tomography (PET)/computed tomography (CT) technology. The strengths and limitations of FDG PET/CT are examined in various clinical settings, and the following questions are answered: Is FDG PET/CT useful to differentiate malignant from benign breast lesions? Can FDG PET/CT replace sentinel node biopsy for axillary staging? What is the role of FDG PET/CT in initial staging of inflammatory or locally advanced breast cancer? What is the role of FDG PET/CT in initial staging of clinical stage IIA and IIB and primary operable stage IIIA breast cancer? How does FDG PET/CT compare with conventional techniques in the restaging of cancer in patients who are suspected of having disease recurrence? What is the role of FDG PET/CT in the assessment of early response to neoadjuvant therapy and of response to therapy for metastatic disease? Some recommendations for clinical practice are given.
Yoon, Hongkyu; Oostrom, Mart; Wietsma, Thomas W; Werth, Charles J; Valocchi, Albert J
2009-10-13
The purpose of this work is to identify the mechanisms that govern the removal of carbon tetrachloride (CT) during soil vapor extraction (SVE) by comparing numerical and analytical model simulations with a detailed data set from a well-defined intermediate-scale flow cell experiment. The flow cell was packed with a fine-grained sand layer embedded in a coarse-grained sand matrix. A total of 499 mL CT was injected at the top of the flow cell and allowed to redistribute in the variably saturated system. A dual-energy gamma radiation system was used to determine the initial NAPL saturation profile in the fine-grained sand layer. Gas concentrations at the outlet of the flow cell and 15 sampling ports inside the flow cell were measured during subsequent CT removal using SVE. Results show that CT mass was removed quickly in coarse-grained sand, followed by a slow removal from the fine-grained sand layer. Consequently, effluent gas concentrations decreased quickly at first, and then started to decrease gradually, resulting in long-term tailing. The long-term tailing was mainly due to diffusion from the fine-grained sand layer to the coarse-grained sand zone. An analytical solution for a one-dimensional advection and a first-order mass transfer model matched the tailing well with two fitting parameters. Given detailed knowledge of the permeability field and initial CT distribution, we were also able to predict the effluent concentration tailing and gas concentration profiles at sampling ports using a numerical simulator assuming equilibrium CT evaporation. The numerical model predictions were accurate within the uncertainty of independently measured or literature derived parameters. This study demonstrates that proper numerical modeling of CT removal through SVE can be achieved using equilibrium evaporation of NAPL if detailed fine-scale knowledge of the CT distribution and physical heterogeneity is incorporated into the model. However, CT removal could also be fit by a first-order mass transfer analytical model, potentially leading to an erroneous conclusion that the long-term tailing in the experiment was kinetically controlled due to rate-limited NAPL evaporation.
Taylor, Richard Andrew; Singh Gill, Harman; Marcolini, Evie G; Meyers, H Pendell; Faust, Jeremy Samuel; Newman, David H
2016-10-01
The objective was to determine the testing threshold for lumbar puncture (LP) in the evaluation of aneurysmal subarachnoid hemorrhage (SAH) after a negative head computed tomography (CT). As a secondary aim we sought to identify clinical variables that have the greatest impact on this threshold. A decision analytic model was developed to estimate the testing threshold for patients with normal neurologic findings, being evaluated for SAH, after a negative CT of the head. The testing threshold was calculated as the pretest probability of disease where the two strategies (LP or no LP) are balanced in terms of quality-adjusted life-years. Two-way and probabilistic sensitivity analyses (PSAs) were performed. For the base-case scenario the testing threshold for performing an LP after negative head CT was 4.3%. Results for the two-way sensitivity analyses demonstrated that the test threshold ranged from 1.9% to 15.6%, dominated by the uncertainty in the probability of death from initial missed SAH. In the PSA the mean testing threshold was 4.3% (95% confidence interval = 1.4% to 9.3%). Other significant variables in the model included probability of aneurysmal versus nonaneurysmal SAH after negative head CT, probability of long-term morbidity from initial missed SAH, and probability of renal failure from contrast-induced nephropathy. Our decision analysis results suggest a testing threshold for LP after negative CT to be approximately 4.3%, with a range of 1.4% to 9.3% on robust PSA. In light of these data, and considering the low probability of aneurysmal SAH after a negative CT, classical teaching and current guidelines addressing testing for SAH should be revisited. © 2016 by the Society for Academic Emergency Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moignier, Alexandra, E-mail: alexandra.moignier@irsn.fr; Derreumaux, Sylvie; Broggio, David
Purpose: Current retrospective cardiovascular dosimetry studies are based on a representative patient or simple mathematic phantoms. Here, a process of patient modeling was developed to personalize the anatomy of the thorax and to include a heart model with coronary arteries. Methods and Materials: The patient models were hybrid computational phantoms (HCPs) with an inserted detailed heart model. A computed tomography (CT) acquisition (pseudo-CT) was derived from HCP and imported into a treatment planning system where treatment conditions were reproduced. Six current patients were selected: 3 were modeled from their CT images (A patients) and the others were modelled from 2more » orthogonal radiographs (B patients). The method performance and limitation were investigated by quantitative comparison between the initial CT and the pseudo-CT, namely, the morphology and the dose calculation were compared. For the B patients, a comparison with 2 kinds of representative patients was also conducted. Finally, dose assessment was focused on the whole coronary artery tree and the left anterior descending coronary. Results: When 3-dimensional anatomic information was available, the dose calculations performed on the initial CT and the pseudo-CT were in good agreement. For the B patients, comparison of doses derived from HCP and representative patients showed that the HCP doses were either better or equivalent. In the left breast radiation therapy context and for the studied cases, coronary mean doses were at least 5-fold higher than heart mean doses. Conclusions: For retrospective dose studies, it is suggested that HCP offers a better surrogate, in terms of dose accuracy, than representative patients. The use of a detailed heart model eliminates the problem of identifying the coronaries on the patient's CT.« less
Lee, Geewon; Kim, Ki Uk; Lee, Ji Won; Suh, Young Ju; Jeong, Yeon Joo
2017-05-01
Background Although fibrotic idiopathic interstitial pneumonias (IIPs) alone and those combined with pulmonary emphysema are naturally progressive diseases, the process of deterioration and outcomes are variable. Purpose To evaluate and compare serial changes of computed tomography (CT) abnormalities and prognostic predictive factors in fibrotic IIPs alone and those combined with pulmonary emphysema. Material and Methods A total of 148 patients with fibrotic IIPs alone (82 patients) and those combined with pulmonary emphysema (66 patients) were enrolled. Semi-quantitative CT analysis was used to assess the extents of CT characteristics which were evaluated on initial and follow-up CT images. Univariate and multivariate analyses were performed to assess the effects of clinical and CT variables on survival. Results Significant differences were noted between fibrotic scores, as determined using initial CT scans, in the fibrotic IIPs alone (21.22 ± 9.83) and those combined with pulmonary emphysema groups (14.70 ± 7.28) ( P < 0.001). At follow-up CT scans, changes in the extent of ground glass opacities (GGO) were greater ( P = 0.031) and lung cancer was more prevalent ( P = 0.001) in the fibrotic IIPs combined with pulmonary emphysema group. Multivariate Cox proportional hazards analysis showed changes in the extent of GGO (hazard ratio, 1.056) and the presence of lung cancer (hazard ratio, 4.631) were predictive factors of poor survivals. Conclusion Although patients with fibrotic IIPs alone and those combined with pulmonary emphysema have similar mortalities, lung cancer was more prevalent in patients with fibrotic IIPs combined with pulmonary emphysema. Furthermore, changes in the extent of GGO and the presence of lung cancer were independent prognostic factors of poor survivals.
SU-F-J-188: Clinical Implementation of in Room Mobile CT for Image Guided Proton Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, H; Wu, R; Poenisch, F
Purpose: To implement soft-tissue image-guided proton therapy using inroom mobile CT. Methods: Anthropomorphic phantom was first used to determine the setup accuracy using in- room mobile CT. Laser and bbs were used for the initial setup (marked isocenter). CT data was then acquired with in-room mobile CT (daily CT). The shift between the marked isocenter and the planned isocenter (final isocenter) was determined from the daily CT using in-house Computer Assisted Targeting (CAT) software. Orthogonal DRRs of the day was also generated from the daily CT. The phantom was then transferred on the treatment couch top to the treatment machinemore » using a transportation system, and again aligned to the marked isocenter. Couch shifts were made to align the phantom to the final isocenter using the shifts as determined using the CAT software, and verified using orthogonal X-ray images with the daily DRRs. Results: Phantom data suggests that following the setup procedure as described above, targeting accuracy could be within 1 mm. Patient data are being acquired and analyzed. Conclusion: In-room mobile CT is capable of providing soft-tissue image-guided proton therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2011-02-15
Purpose: The development of computer-aided diagnostic (CAD) methods for lung nodule detection, classification, and quantitative assessment can be facilitated through a well-characterized repository of computed tomography (CT) scans. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI) completed such a database, establishing a publicly available reference for the medical imaging research community. Initiated by the National Cancer Institute (NCI), further advanced by the Foundation for the National Institutes of Health (FNIH), and accompanied by the Food and Drug Administration (FDA) through active participation, this public-private partnership demonstrates the success of a consortium founded on a consensus-based process.more » Methods: Seven academic centers and eight medical imaging companies collaborated to identify, address, and resolve challenging organizational, technical, and clinical issues to provide a solid foundation for a robust database. The LIDC/IDRI Database contains 1018 cases, each of which includes images from a clinical thoracic CT scan and an associated XML file that records the results of a two-phase image annotation process performed by four experienced thoracic radiologists. In the initial blinded-read phase, each radiologist independently reviewed each CT scan and marked lesions belonging to one of three categories (''nodule{>=}3 mm,''''nodule<3 mm,'' and ''non-nodule{>=}3 mm''). In the subsequent unblinded-read phase, each radiologist independently reviewed their own marks along with the anonymized marks of the three other radiologists to render a final opinion. The goal of this process was to identify as completely as possible all lung nodules in each CT scan without requiring forced consensus. Results: The Database contains 7371 lesions marked ''nodule'' by at least one radiologist. 2669 of these lesions were marked ''nodule{>=}3 mm'' by at least one radiologist, of which 928 (34.7%) received such marks from all four radiologists. These 2669 lesions include nodule outlines and subjective nodule characteristic ratings. Conclusions: The LIDC/IDRI Database is expected to provide an essential medical imaging research resource to spur CAD development, validation, and dissemination in clinical practice.« less
Initial FDG-PET/CT predicts survival in adults Ewing sarcoma family of tumors
Jamet, Bastien; Carlier, Thomas; Campion, Loic; Bompas, Emmanuelle; Girault, Sylvie; Borrely, Fanny; Ferrer, Ludovic; Rousseau, Maxime; Venel, Yann; Kraeber-Bodéré, Françoise; Rousseau, Caroline
2017-01-01
Purpose The aim of this retrospective study was to determine, at baseline, the prognostic value of different FDG-PET/CT quantitative parameters in a homogenous Ewing Sarcoma Family of Tumors (ESFT) adult population, compared with clinically relevant prognostic factors. Methods Adult patients from 3 oncological centers, all with proved ESFT, were retrospectively included. Quantitative FDG-PET/CT parameters (SUV (maximum, peak and mean), metabolic tumor volume (MTV) and total lesion glycolysis (TLG) of the primary lesion of each patient were recorded before treatment, as well as usual clinical prognostic factors (stage of disease, location, tumor size, gender and age). Then, their relation with progression free survival (PFS) and overall survival (OS) was evaluated. Results 32 patients were included. Median age was 21 years (range, 15 to 61). Nineteen patients (59%) were initially metastatic. On multivariate analysis, high SUVmax remained independent predictor of worst OS (p=0.02) and PFS (p=0.019), metastatic disease of worst PFS (p=0.01) and high SUVpeak of worst OS (p=0.01). Optimal prognostic cut-off of SUVpeak was found at 12.5 in multivariate analyses for PFS and OS (p=0.0001). Conclusions FDG-PET/CT, recommended at ESFT diagnosis for initial staging, can be a useful tool for predicting long-term adult patients outcome through semi-quantitative parameters. PMID:29100369
NASA Astrophysics Data System (ADS)
Vickstrom, K. E.; Azizian, M.; Semprini, L.
2015-12-01
Carbon tetrachloride (CT) is a toxic and recalcitrant groundwater contaminant with the potential to form a broad range of transformation products. Of the possible biochemical pathways through which CT can be degraded, reductive dehalogenation to less chlorinated compounds and mineralization to carbon dioxide (CO2) appear to be the most frequently utilized pathways by anaerobic organisms. Results will be presented from batch experiments of CT degradation by the Evanite (EV), Victoria Strain (VS) and Point Mugu (PM) anaerobic dechlorinating cultures. The cultures are grown in chemostats and are capable of transforming tetrachloroethene (PCE) or trichloroethene (TCE) to ethene by halorespiration via reductive dehalogenase enzymes. For the batch CT transformation tests, the cells along with supernatant were harvested from chemostats fed PCE or TCE, but never CT. The batch reactors were initially fed 0.0085 mM CT and an excess of formate (EV and VS) or lactate (PM) as electron donor. Transformation of CT was 100% with about 20% converted to chloroform (CF) and undetected products. Multiple additions of CT showed a slowing of pseudo first-order CT transformation rates across all cultures. Batch reactors were then established and fed 0.085 mM CT with an excess of electron donor in order to better quantify the reductive pathway. CT was transformed to CF and dichloromethane (DCM), with trace amounts of chloromethane (CM) detected. Between 60-90% of the mass added to the system was accounted for, showing that the majority of the carbon tetrachloride present is being reductively dehalogenated. Results from batch reactors that were poisoned using sodium azide, and from reactors not provided electron donor will be presented to distinguish between biotic and abiotic reactions. Furthermore, results from reactors prepared with acetylene (a potent, reversible inhibitor of reductive dehalogenases (1)) will be presented as a means of identifying the enzymes involved in the transformation of CT. The results clearly demonstrate that reductive dechlorination of CT can be promoted by anaerobic cultures not previously acclimated to CT. 1. G. Pon, M. R. Hyman, L. Semprini, Environ. Sci. Technol. 37, 3181-3188 (2003).
Wan, Chih-Hsing; Tseng, Jing-Ren; Lee, Ming-Hsun; Yang, Lan-Yan; Yen, Tzu-Chen
2018-03-01
Acute complicated pyelonephritis (ACP) is an upper urinary tract infection associated with coexisting urinary tract abnormalities or medical conditions that could predispose to serious outcomes or treatment failures. Although CT and magnetic resonance imaging (MRI) are frequently used in patients with ACP, the clinical value of 18 F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) has not been systematically investigated. This single-center retrospective study was designed to evaluate the potential usefulness of FDG PET/CT in patients with ACP. Thirty-one adult patients with ACP who underwent FDG PET/CT were examined. FDG PET/CT imaging characteristics, including tracer uptake patterns, kidney volumes, and extrarenal imaging findings, were reviewed in combination with clinical data and conventional imaging results. Of the 31 patients, 19 (61%) showed focal FDG uptake. The remaining 12 study participants showed a diffuse FDG uptake pattern. After volumetric approximation, the affected kidneys were found to be significantly enlarged. Patients who showed a focal uptake pattern had a higher frequency of abscess formation requiring drainage. ACP patients showing diffuse tracer uptake patterns had a more benign clinical course. Seven patients had suspected extrarenal coinfections, and FDG PET/CT successfully confirmed the clinical suspicion in five cases. FDG PET/CT was as sensitive as CT in identifying the six patients (19%) who developed abscesses. Notably, FDG PET/CT findings caused a modification to the initial antibiotic regimen in nine patients (29%). FDG PET/CT may be clinically useful in the assessment of patients with ACP who have a progressive disease course.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hepel, Jaroslaw T.; Department of Radiation Oncology, Brown University, Rhode Island Hospital, Providence, RI; Evans, Suzanne B.
2009-06-01
Purpose: To evaluate the accuracy of two clinical techniques for electron boost planning compared with computed tomography (CT)-based planning. Additionally, we evaluated the tumor bed characteristics at whole breast planning and boost planning. Methods and Materials: A total of 30 women underwent tumor bed boost planning within 2 weeks of completing whole breast radiotherapy using three planning techniques: scar-based planning, palpation/clinical-based planning, and CT-based planning. The plans were analyzed for dosimetric coverage of the CT-delineated tumor bed. The cavity visualization score was used to define the CT-delineated tumor bed as well or poorly defined. Results: Scar-based planning resulted in inferiormore » tumor bed coverage compared with CT-based planning, with the minimal dose received by 90% of the target volume >90% in 53% and a geographic miss in 53%. The results of palpation/clinical-based planning were significantly better: 87% and 10% for the minimal dose received by 90% of the target volume >90% and geographic miss, respectively. Of the 30 tumor beds, 16 were poorly defined by the cavity visualization score. Of these 16, 8 were well demarcated by the surgical clips. The evaluation of the 22 well-defined tumor beds revealed similar results. A comparison of the tumor bed volume from the initial planning CT scan to the boost planning CT scan revealed a decrease in size in 77% of cases. The mean decrease in volume was 52%. Conclusion: The results of our study have shown that CT-based planning allows for optimal tumor bed coverage compared with clinical and scar-based approaches. However, in the setting of a poorly visualized cavity on CT without surgical clips, palpation/clinical-based planning can help delineate the appropriate target volumes and is superior to scar-based planning. CT simulation at boost planning could allow for a reduction in the boost volumes.« less
Development of a semi-automated combined PET and CT lung lesion segmentation framework
NASA Astrophysics Data System (ADS)
Rossi, Farli; Mokri, Siti Salasiah; Rahni, Ashrani Aizzuddin Abd.
2017-03-01
Segmentation is one of the most important steps in automated medical diagnosis applications, which affects the accuracy of the overall system. In this paper, we propose a semi-automated segmentation method for extracting lung lesions from thoracic PET/CT images by combining low level processing and active contour techniques. The lesions are first segmented in PET images which are first converted to standardised uptake values (SUVs). The segmented PET images then serve as an initial contour for subsequent active contour segmentation of corresponding CT images. To evaluate its accuracy, the Jaccard Index (JI) was used as a measure of the accuracy of the segmented lesion compared to alternative segmentations from the QIN lung CT segmentation challenge, which is possible by registering the whole body PET/CT images to the corresponding thoracic CT images. The results show that our proposed technique has acceptable accuracy in lung lesion segmentation with JI values of around 0.8, especially when considering the variability of the alternative segmentations.
Son, Seong; Lee, Sang Gu; Kim, Eun Young; Park, Chan Woo; Kim, Woo Kyung
2013-01-01
Objective The objectives of the present study were to characterize the natural course of initially non-operated traumatic acute subdural hematoma (ASDH) and to identify the risk factors of hematoma progression. Methods Retrospective analysis was performed using sequential computed tomography (CT) images maintained in a prospective observational database containing 177 ASDH cases treated from 2005 to 2011. Patients were allocated to four groups as followings; 136 (76.8%) patients to the spontaneous resolution group, 12 (6.8%) who underwent operation between 4 hours and 7 days to the rapid worsening group (RWG), 24 (13.6%) who experienced an increase of hematoma and that underwent operation between 7 and 28 days to the subacute worsening group (SWG), and 5 (2.8%) who developed delayed aggravation requiring surgery from one month after onset to the delayed worsening group (DWG). Groups were compared with respect to various factors. Results No significant intergroup difference was found with respect to age, mechanism of injury, or initial Glasgow Coma Scale. The presence of combined cerebral contusion or subarachnoid hemorrhage was found to be a significant prognostic factor. Regarding CT findings, mixed density was common in the RWG and the SWG. Midline shifting, hematoma thickness, and numbers of CT slices containing hematoma were significant prognostic factors of the RWG and the SWG. Brain atrophy was more severe in the SWG and the DWG. Conclusion A large proportion of initially non-operated ASDHs worsen in the acute or subacute phase. Patients with risk factors should be monitored carefully for progression by repeat CT imaging. PMID:24278650
NASA Astrophysics Data System (ADS)
Zhang, Weipeng
2017-06-01
The relationship between the medical characteristics of lung cancers and computer tomography (CT) images are explored so as to improve the early diagnosis rate of lung cancers. This research collected CT images of patients with solitary pulmonary nodule lung cancer, and used gradual clustering methodology to classify them. Preliminary classifications were made, followed by continuous modification and iteration to determine the optimal condensation point, until iteration stability was achieved. Reasonable classification results were obtained. the clustering results fell into 3 categories. The first type of patients was mostly female, with ages between 50 and 65 years. CT images of solitary pulmonary nodule lung cancer for this group contain complete lobulation and burr, with pleural indentation; The second type of patients was mostly male with ages between 50 and 80 years. CT images of solitary pulmonary nodule lung cancer for this group contain complete lobulation and burr, but with no pleural indentation; The third type of patients was also mostly male with ages between 50 and 80 years. CT images for this group showed no abnormalities. the application of gradual clustering methodology can scientifically classify CT image features of patients with lung cancer in the initial lesion stage. These findings provide the basis for early detection and treatment of malignant lesions in patients with lung cancer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freund, D; Ding, X; Zhang, J
Purpose: In prostate proton radiotherapy, three fiducial markers are used for patient daily alignment. However fiducial alignment can change beamline heterogeneity in proton therapy. The purpose of this study is to determine the difference in fiducial and boney anatomy alignment for patient treatment. Methods and materials: Prostate cancer patients who received proton treatment were included in this study. 3 fiducial markers were implanted before the initial CT. All the patients were re-CT’d every 2 weeks to check the fiducial marker position reproducibility as well as dosimetric consistence of target coverage. In geometry study, re-CT were fused to the initial CTmore » base on the boney anatomy and the average fiducial marker displacement was measured the centers of the fiducials. Dosimetrically, the initial plan was recalculated directly to re-CT image set based on the boney alignment and fiducial alignment to determine the difference from daily treatment. Prostate coverage and hotspots were evaluated using the dose to 98% of the CTV (D98) and dose to 2% (D2), respectively. Results: The shift from the initial 6 patient CT image sets resulted in an average change in the fiducial location of 5.70 +/− 3 mm. Dosimetric comparison from a single patient revealed that differences from the planned dose resulted from both boney and fiducial alignment. Planned clinical treatment volume coverage resulted in a D98 of 70.44Gy and D2 of 70.84Gy compared to a D98 of 70.13Gy and D2 70.94Gy for boney alignment and a D98 of 70.08Gy and D2 71.18Gy for fiducial alignment respectively. Conclusion: This study demonstrates that with boney anatomy alignment there is little change to CTV coverage and only slightly worse CTV coverage and hotspot production with fiducial alignment. An increase patient cohort and further investigation is necessary to determine the whether boney alignment can help better control dose heterogeneity.« less
Feature-based US to CT registration of the aortic root
NASA Astrophysics Data System (ADS)
Lang, Pencilla; Chen, Elvis C. S.; Guiraudon, Gerard M.; Jones, Doug L.; Bainbridge, Daniel; Chu, Michael W.; Drangova, Maria; Hata, Noby; Jain, Ameet; Peters, Terry M.
2011-03-01
A feature-based registration was developed to align biplane and tracked ultrasound images of the aortic root with a preoperative CT volume. In transcatheter aortic valve replacement, a prosthetic valve is inserted into the aortic annulus via a catheter. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to significant morbidity and mortality. Registration of pre-operative CT to transesophageal ultrasound and fluoroscopy images is a major step towards providing augmented image guidance for this procedure. The proposed registration approach uses an iterative closest point algorithm to register a surface mesh generated from CT to 3D US points reconstructed from a single biplane US acquisition, or multiple tracked US images. The use of a single simultaneous acquisition biplane image eliminates reconstruction error introduced by cardiac gating and TEE probe tracking, creating potential for real-time intra-operative registration. A simple initialization procedure is used to minimize changes to operating room workflow. The algorithm is tested on images acquired from excised porcine hearts. Results demonstrate a clinically acceptable accuracy of 2.6mm and 5mm for tracked US to CT and biplane US to CT registration respectively.
Gayana, Shankaramurthy; Bhattacharya, Anish; Sen, Ramesh Kumar; Singh, Paramjeet; Prakash, Mahesh; Mittal, Bhagwant Rai
2016-01-01
Objective: Femoral head avascular necrosis (FHAVN) is one of the increasingly common causes of musculoskeletal disability and poses a major diagnostic and therapeutic challenge. Although radiography, scintigraphy, computed tomography (CT), and magnetic resonance imaging (MRI) have been widely used in the diagnosis of FHAVN, positron emission tomography (PET) has recently been evaluated to assess vascularity of the femoral head. In this study, the authors compared F-18 fluoride PET/CT with MRI in the initial diagnosis of FHAVN. Patients and Methods: We prospectively studied 51 consecutive patients with a high clinical suspicion of FHAVN. All patients underwent MRI and F-18 fluoride PET/CT, the time interval between the two scans being 4–10 (mean 8) days. Two nuclear medicine physicians blinded to the MRI report read the PET/CT scans. Clinical assessment was also done. Final diagnoses were made by surgical pathology or clinical and radiologic follow-up. Results: A final diagnosis of avascular necrosis (AVN) was made in 40 patients. MRI was 96.5% sensitive, 100% specific, and 98.03% accurate while PET/CT was 100% sensitive, specific, and accurate in diagnosing FHAVN. The agreement between the two imaging modalities for the diagnosis of AVN was 96.07%. Conclusion: F-18 fluoride PET/CT showed good agreement with MRI in the initial diagnosis of FHAVN and can be better than MRI in detecting early disease. PMID:26917886
Peripheral Quantitative CT (pQCT) Using a Dedicated Extremity Cone-Beam CT Scanner
Muhit, A. A.; Arora, S.; Ogawa, M.; Ding, Y.; Zbijewski, W.; Stayman, J. W.; Thawait, G.; Packard, N.; Senn, R.; Yang, D.; Yorkston, J.; Bingham, C.O.; Means, K.; Carrino, J. A.; Siewerdsen, J. H.
2014-01-01
Purpose We describe the initial assessment of the peripheral quantitative CT (pQCT) imaging capabilities of a cone-beam CT (CBCT) scanner dedicated to musculoskeletal extremity imaging. The aim is to accurately measure and quantify bone and joint morphology using information automatically acquired with each CBCT scan, thereby reducing the need for a separate pQCT exam. Methods A prototype CBCT scanner providing isotropic, sub-millimeter spatial resolution and soft-tissue contrast resolution comparable or superior to standard multi-detector CT (MDCT) has been developed for extremity imaging, including the capability for weight-bearing exams and multi-mode (radiography, fluoroscopy, and volumetric) imaging. Assessment of pQCT performance included measurement of bone mineral density (BMD), morphometric parameters of subchondral bone architecture, and joint space analysis. Measurements employed phantoms, cadavers, and patients from an ongoing pilot study imaged with the CBCT prototype (at various acquisition, calibration, and reconstruction techniques) in comparison to MDCT (using pQCT protocols for analysis of BMD) and micro-CT (for analysis of subchondral morphometry). Results The CBCT extremity scanner yielded BMD measurement within ±2–3% error in both phantom studies and cadaver extremity specimens. Subchondral bone architecture (bone volume fraction, trabecular thickness, degree of anisotropy, and structure model index) exhibited good correlation with gold standard micro-CT (error ~5%), surpassing the conventional limitations of spatial resolution in clinical MDCT scanners. Joint space analysis demonstrated the potential for sensitive 3D joint space mapping beyond that of qualitative radiographic scores in application to non-weight-bearing versus weight-bearing lower extremities and assessment of phalangeal joint space integrity in the upper extremities. Conclusion The CBCT extremity scanner demonstrated promising initial results in accurate pQCT analysis from images acquired with each CBCT scan. Future studies will include improved x-ray scatter correction and image reconstruction techniques to further improve accuracy and to correlate pQCT metrics with known pathology. PMID:25076823
Signal Transduction in Receptor for Advanced Glycation End Products (RAGE)
Rai, Vivek; Maldonado, Andres Y.; Burz, David S.; Reverdatto, Sergey; Schmidt, Ann Marie; Shekhtman, Alexander
2012-01-01
The receptor for advanced glycation end products (RAGE) is a multiligand cell surface macromolecule that plays a central role in the etiology of diabetes complications, inflammation, and neurodegeneration. The cytoplasmic domain of RAGE (C-terminal RAGE; ctRAGE) is critical for RAGE-dependent signal transduction. As the most membrane-proximal event, mDia1 binds to ctRAGE, and it is essential for RAGE ligand-stimulated phosphorylation of AKT and cell proliferation/migration. We show that ctRAGE contains an unusual α-turn that mediates the mDia1-ctRAGE interaction and is required for RAGE-dependent signaling. The results establish a novel mechanism through which an extracellular signal initiated by RAGE ligands regulates RAGE signaling in a manner requiring mDia1. PMID:22194616
Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT
Queiroz, Marcelo A.; Delso, Gaspar; Wollenweber, Scott; Deller, Timothy; Zeimpekis, Konstantinos; Huellner, Martin; de Galiza Barbosa, Felipe; von Schulthess, Gustav; Veit-Haibach, Patrick
2015-01-01
Purpose To evaluate the possible activity reduction in FDG-imaging in a Time-of-Flight (TOF) PET/MR, based on cross-evaluation of patient-based NECR (noise equivalent count rate) measurements in PET/CT, cross referencing with phantom-based NECR curves as well as initial evaluation of TOF-PET/MR with reduced activity. Materials and Methods A total of 75 consecutive patients were evaluated in this study. PET/CT imaging was performed on a PET/CT (time-of-flight (TOF) Discovery D 690 PET/CT). Initial PET/MR imaging was performed on a newly available simultaneous TOF-PET/MR (Signa PET/MR). An optimal NECR for diagnostic purposes was defined in clinical patients (NECRP) in PET/CT. Subsequent optimal activity concentration at the acquisition time ([A]0) and target NECR (NECRT) were obtained. These data were used to predict the theoretical FDG activity requirement of the new TOF-PET/MR system. Twenty-five initial patients were acquired with (retrospectively reconstructed) different imaging times equivalent for different activities on the simultaneous PET/MR for the evaluation of clinically realistic FDG-activities. Results The obtained values for NECRP, [A]0 and NECRT were 114.6 (± 14.2) kcps (Kilocounts per second), 4.0 (± 0.7) kBq/mL and 45 kcps, respectively. Evaluating the NECRT together with the phantom curve of the TOF-PET/MR device, the theoretical optimal activity concentration was found to be approximately 1.3 kBq/mL, which represents 35% of the activity concentration required by the TOF-PET/CT. Initial evaluation on patients in the simultaneous TOF-PET/MR shows clinically realistic activities of 1.8 kBq/mL, which represent 44% of the required activity. Conclusion The new TOF-PET/MR device requires significantly less activity to generate PET-images with good-to-excellent image quality, due to improvements in detector geometry and detector technologies. The theoretically achievable dose reduction accounts for up to 65% but cannot be fully translated into clinical routine based on the coils within the FOV and MR-sequences applied at the same time. The clinically realistic reduction in activity is slightly more than 50%. Further studies in a larger number of patients are needed to confirm our findings. PMID:26147919
NASA Astrophysics Data System (ADS)
Zhen, Xin; Chen, Haibin; Yan, Hao; Zhou, Linghong; Mell, Loren K.; Yashar, Catheryn M.; Jiang, Steve; Jia, Xun; Gu, Xuejun; Cervino, Laura
2015-04-01
Deformable image registration (DIR) of fractional high-dose-rate (HDR) CT images is challenging due to the presence of applicators in the brachytherapy image. Point-to-point correspondence fails because of the undesired deformation vector fields (DVF) propagated from the applicator region (AR) to the surrounding tissues, which can potentially introduce significant DIR errors in dose mapping. This paper proposes a novel segmentation and point-matching enhanced efficient DIR (named SPEED) scheme to facilitate dose accumulation among HDR treatment fractions. In SPEED, a semi-automatic seed point generation approach is developed to obtain the incremented fore/background point sets to feed the random walks algorithm, which is used to segment and remove the AR, leaving empty AR cavities in the HDR CT images. A feature-based ‘thin-plate-spline robust point matching’ algorithm is then employed for AR cavity surface points matching. With the resulting mapping, a DVF defining on each voxel is estimated by B-spline approximation, which serves as the initial DVF for the subsequent Demons-based DIR between the AR-free HDR CT images. The calculated DVF via Demons combined with the initial one serve as the final DVF to map doses between HDR fractions. The segmentation and registration accuracy are quantitatively assessed by nine clinical HDR cases from three gynecological cancer patients. The quantitative analysis and visual inspection of the DIR results indicate that SPEED can suppress the impact of applicator on DIR, and accurately register HDR CT images as well as deform and add interfractional HDR doses.
Zhen, Xin; Chen, Haibin; Yan, Hao; Zhou, Linghong; Mell, Loren K; Yashar, Catheryn M; Jiang, Steve; Jia, Xun; Gu, Xuejun; Cervino, Laura
2015-04-07
Deformable image registration (DIR) of fractional high-dose-rate (HDR) CT images is challenging due to the presence of applicators in the brachytherapy image. Point-to-point correspondence fails because of the undesired deformation vector fields (DVF) propagated from the applicator region (AR) to the surrounding tissues, which can potentially introduce significant DIR errors in dose mapping. This paper proposes a novel segmentation and point-matching enhanced efficient DIR (named SPEED) scheme to facilitate dose accumulation among HDR treatment fractions. In SPEED, a semi-automatic seed point generation approach is developed to obtain the incremented fore/background point sets to feed the random walks algorithm, which is used to segment and remove the AR, leaving empty AR cavities in the HDR CT images. A feature-based 'thin-plate-spline robust point matching' algorithm is then employed for AR cavity surface points matching. With the resulting mapping, a DVF defining on each voxel is estimated by B-spline approximation, which serves as the initial DVF for the subsequent Demons-based DIR between the AR-free HDR CT images. The calculated DVF via Demons combined with the initial one serve as the final DVF to map doses between HDR fractions. The segmentation and registration accuracy are quantitatively assessed by nine clinical HDR cases from three gynecological cancer patients. The quantitative analysis and visual inspection of the DIR results indicate that SPEED can suppress the impact of applicator on DIR, and accurately register HDR CT images as well as deform and add interfractional HDR doses.
Rana, A K; Turner, H E; Deans, K A
2013-01-01
Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.
Skoura, Evangelia; Datseris, Ioannis E; Exarhos, Dimitrios; Chatziioannou, Sophia; Oikonomopoulos, Georgios; Samartzis, Alexandros; Giannopoulou, Chariklia; Syrigos, Konstantinos N
2013-05-01
[ 18 F]fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) has been reported to have a low sensitivity in the initial diagnosis of bronchoalveolar carcinoma (BAC) due to BAC's low metabolic activity. The aim of this study was to assess the value of [ 18 F]FDG-PET/CT in the detection of BAC recurrence. Between February 2007 and September 2011, the [ 18 F]FDG-PET/CT scans that were performed on patients with known, histologically proven BAC were studied. A total of 24 [ 18 F]FDG-PET/CT scans were performed in 22 patients, including 16 males and 6 females, with a mean age of 65±9 years. Among the scans, 15 were performed to assess for possible recurrence with equivocal findings in conventional imaging methods and 9 for restaging post-therapy. In all cases conventional imaging studies (CT and MRI) were performed 5-30 days prior to PET/CT. Among the 24 [ 18 F]FDG-PET/CT scans, 18 were positive and 6 negative. Among the 15 [ 18 F]FDG-PET/CT scans performed for suspected recurrence, 34 lesions were detected and the mean maximum standardized uptake value (SUVmax) was 6.8±3.26. In nine scans, upstaging was observed, while two were in agreement with the findings of the conventional modalities. A greater number of lesions were detected in two scans and fewer lesions were detected in one, with no change in staging. Only one scan was negative. By contrast, in patients examined for restaging, there were only five lesions with a mean SUVmax of 4.86±3.18. Agreement between the findings of [ 18 F]FDG-PET/CT and the conventional modalities was observed in 8 out of 9 cases. Although [ 18 F]FDG-PET/CT has been reported to have a low sensitivity in the initial diagnosis of BAC, the present results indicate that when there is recurrence, the lesions become [ 18 F]FDG avid. [ 18 F]FDG-PET/CT may provide further information in patients evaluated for recurrence and thus improve patient management.
Segmenting the Femoral Head and Acetabulum in the Hip Joint Automatically Using a Multi-Step Scheme
NASA Astrophysics Data System (ADS)
Wang, Ji; Cheng, Yuanzhi; Fu, Yili; Zhou, Shengjun; Tamura, Shinichi
We describe a multi-step approach for automatic segmentation of the femoral head and the acetabulum in the hip joint from three dimensional (3D) CT images. Our segmentation method consists of the following steps: 1) construction of the valley-emphasized image by subtracting valleys from the original images; 2) initial segmentation of the bone regions by using conventional techniques including the initial threshold and binary morphological operations from the valley-emphasized image; 3) further segmentation of the bone regions by using the iterative adaptive classification with the initial segmentation result; 4) detection of the rough bone boundaries based on the segmented bone regions; 5) 3D reconstruction of the bone surface using the rough bone boundaries obtained in step 4) by a network of triangles; 6) correction of all vertices of the 3D bone surface based on the normal direction of vertices; 7) adjustment of the bone surface based on the corrected vertices. We evaluated our approach on 35 CT patient data sets. Our experimental results show that our segmentation algorithm is more accurate and robust against noise than other conventional approaches for automatic segmentation of the femoral head and the acetabulum. Average root-mean-square (RMS) distance from manual reference segmentations created by experienced users was approximately 0.68mm (in-plane resolution of the CT data).
Ultra low-dose CT attenuation correction in PET SPM
NASA Astrophysics Data System (ADS)
Wang, Shyh-Jen; Yang, Bang-Hung; Tsai, Chia-Jung; Yang, Ching-Ching; Lee, Jason J. S.; Wu, Tung-Hsin
2010-07-01
The use of CT images for attenuation correction (CTAC) allows significantly shorter scanning time and a high quality noise-free attenuation map compared with conventional germanium-68 transmission scan because at least 10 4 times greater of photon flux would be generated from a CT scan under standard operating condition. However, this CTAC technique would potentially introduce more radiation risk to the patients owing to the higher radiation exposure from CT scan. Statistic parameters mapping (SPM) is a prominent technique in nuclear medicine community for the analysis of brain imaging data. The purpose of this study is to assess the feasibility of low-dose CT (LDCT) and ultra low-dose CT (UDCT) in PET SPM applications. The study was divided into two parts. The first part was to evaluate of tracer uptake distribution pattern and quantity analysis by using the striatal phantom to initially assess the feasibility of AC for clinical purpose. The second part was to examine the group SPM analysis using the Hoffman brain phantom. The phantom study is to simulate the human brain and to reduce the experimental uncertainty of real subjects. The initial studies show that the results of PET SPM analysis have no significant differences between LDCT and UDCT comparing to the current used default CTAC. Moreover, the dose of the LDCT is lower than that of the default CT by a factor of 9, and UDCT can even yield a 42 times dose reduction. We have demonstrated the SPM results while using LDCT and UDCT for PET AC is comparable to those using default CT setting, suggesting their feasibility in PET SPM applications. In addition, the necessity of UDCT in PET SPM studies to avoid excess radiation dose is also evident since most of the subjects involved are non-cancer patients or children and some normal subjects are even served as a comparison group in the experiment. It is our belief that additional attempts to decrease the radiation dose would be valuable, especially for children and normal volunteers, to work towards ALARA (as low as reasonably achievable) concept for PET SPM studies.
Patient participation in cancer clinical trials: A pilot test of lay navigation.
Cartmell, Kathleen B; Bonilha, Heather S; Matson, Terri; Bryant, Debbie C; Zapka, Jane G; Bentz, Tricia A; Ford, Marvella E; Hughes-Halbert, Chanita; Simpson, Kit N; Alberg, Anthony J
2016-08-15
Clinical trials (CT) represent an important treatment option for cancer patients. Unfortunately, patients face challenges to enrolling in CTs, such as logistical barriers, poor CT understanding and complex clinical regimens. Patient navigation is a strategy that may help to improve the delivery of CT education and support services. We examined the feasibility and initial effect of one navigation strategy, use of lay navigators. A lay CT navigation intervention was evaluated in a prospective cohort study among 40 lung and esophageal cancer patients. The intervention was delivered by a trained lay navigator who viewed a 17-minute CT educational video with each patient, assessed and answered their questions about CT participation and addressed reported barriers to care and trial participation. During this 12-month pilot project, 85% (95% CI: 72%-93%) of patients eligible for a therapeutic CT consented to participate in the CT navigation intervention. Among navigated patients, CT understanding improved between pre- and post-test (means 3.54 and 4.40, respectively; p-value 0.004), and 95% (95% CI: 82%-98%) of navigated patients consented to participate in a CT. Navigated patients reported being satisfied with patient navigation services and CT participation. In this formative single-arm pilot project, initial evidence was found for the potential effect of a lay navigation intervention on CT understanding and enrollment. A randomized controlled trial is needed to examine the efficacy of the intervention for improving CT education and enrollment.
Gimbel, Ronald W; Pirrallo, Ronald G; Lowe, Steven C; Wright, David W; Zhang, Lu; Woo, Min-Jae; Fontelo, Paul; Liu, Fang; Connor, Zachary
2018-03-12
The frequency of head computed tomography (CT) imaging for mild head trauma patients has raised safety and cost concerns. Validated clinical decision rules exist in the published literature and on-line sources to guide medical image ordering but are often not used by emergency department (ED) clinicians. Using simulation, we explored whether the presentation of a clinical decision rule (i.e. Canadian CT Head Rule - CCHR), findings from malpractice cases related to clinicians not ordering CT imaging in mild head trauma cases, and estimated patient out-of-pocket cost might influence clinician brain CT ordering. Understanding what type and how information may influence clinical decision making in the ordering advanced medical imaging is important in shaping the optimal design and implementation of related clinical decision support systems. Multi-center, double-blinded simulation-based randomized controlled trial. Following standardized clinical vignette presentation, clinicians made an initial imaging decision for the patient. This was followed by additional information on decision support rules, malpractice outcome review, and patient cost; each with opportunity to modify their initial order. The malpractice and cost information differed by assigned group to test the any temporal relationship. The simulation closed with a second vignette and an imaging decision. One hundred sixteen of the 167 participants (66.9%) initially ordered a brain CT scan. After CCHR presentation, the number of clinicians ordering a CT dropped to 76 (45.8%), representing a 21.1% reduction in CT ordering (P = 0.002). This reduction in CT ordering was maintained, in comparison to initial imaging orders, when presented with malpractice review information (p = 0.002) and patient cost information (p = 0.002). About 57% of clinicians changed their order during study, while 43% never modified their imaging order. This study suggests that ED clinician brain CT imaging decisions may be influenced by clinical decision support rules, patient out-of-pocket cost information and findings from malpractice case review. NCT03449862 , February 27, 2018, Retrospectively registered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ladra, Matthew M.; Mandeville, Henry C.; Niemierko, Andrzej
2015-06-01
Background: Local control remains a challenge in pediatric parameningeal rhabdomyosarcoma (PM-RMS), and survival after local failure (LF) is poor. Identifying patients with a high risk of LF is of great interest to clinicians. In this study, we examined whether tumor response to induction chemotherapy (CT) could predict LF in embryonal PM-RMS. Methods: We identified 24 patients with embryonal PM-RMS, age 2 to 18 years, with complete magnetic resonance imaging and gross residual disease after surgical resection. All patients received proton radiation therapy (RT), median dose 50.4 Gy{sub RBE} (50.4-55.8 Gy{sub RBE}). Tumor size was measured before initial CT and before RT. Results:more » With a median follow-up time of 4.1 years for survivors, LF was seen in 9 patients (37.5%). The median time from the initiation of CT to the start of RT was 4.8 weeks. Patients with LF had a similar initial (pre-CT) tumor volume compared with patients with local controlled (LC) (54 cm{sup 3} vs 43 cm{sup 3}, P=.9) but a greater median volume before RT (pre-RT) (40 cm{sup 3} vs 7 cm{sup 3}, P=.009) and a smaller median relative percent volume reduction (RPVR) in tumor size (0.4% vs 78%, P<.001). Older age (P=.05), larger pre-RT tumor volume (P=.03), and smaller RPVR (P=.003) were significantly associated with actuarial LF on univariate Cox analysis. Conclusions: Poor response to induction CT appears to be associated with an increased risk of LF in pediatric embryonal PM-RMS.« less
Citalopram and escitalopram plasma drug and metabolite concentrations: genome-wide associations
Ji, Yuan; Schaid, Daniel J; Desta, Zeruesenay; Kubo, Michiaki; Batzler, Anthony J; Snyder, Karen; Mushiroda, Taisei; Kamatani, Naoyuki; Ogburn, Evan; Hall-Flavin, Daniel; Flockhart, David; Nakamura, Yusuke; Mrazek, David A; Weinshilboum, Richard M
2014-01-01
Aims Citalopram (CT) and escitalopram (S-CT) are among the most widely prescribed selective serotonin reuptake inhibitors used to treat major depressive disorder (MDD). We applied a genome-wide association study to identify genetic factors that contribute to variation in plasma concentrations of CT or S-CT and their metabolites in MDD patients treated with CT or S-CT. Methods Our genome-wide association study was performed using samples from 435 MDD patients. Linear mixed models were used to account for within-subject correlations of longitudinal measures of plasma drug/metabolite concentrations (4 and 8 weeks after the initiation of drug therapy), and single-nucleotide polymorphisms (SNPs) were modelled as additive allelic effects. Results Genome-wide significant associations were observed for S-CT concentration with SNPs in or near the CYP2C19 gene on chromosome 10 (rs1074145, P = 4.1 × 10−9) and with S-didesmethylcitalopram concentration for SNPs near the CYP2D6 locus on chromosome 22 (rs1065852, P = 2.0 × 10−16), supporting the important role of these cytochrome P450 (CYP) enzymes in biotransformation of citalopram. After adjustment for the effect of CYP2C19 functional alleles, the analyses also identified novel loci that will require future replication and functional validation. Conclusions In vitro and in vivo studies have suggested that the biotransformation of CT to monodesmethylcitalopram and didesmethylcitalopram is mediated by CYP isozymes. The results of our genome-wide association study performed in MDD patients treated with CT or S-CT have confirmed those observations but also identified novel genomic loci that might play a role in variation in plasma levels of CT or its metabolites during the treatment of MDD patients with these selective serotonin reuptake inhibitors. PMID:24528284
Benedetti, Nancy; Aslam, Rizwan; Wang, Zhen J.; Joe, Bonnie N.; Fu, Yanjun; Yee, Judy; Yeh, Benjamin M.
2010-01-01
OBJECTIVE The objective of our study was to determine the prevalence and clinical predictors of delayed contrast enhancement of ascites. MATERIALS AND METHODS In this retrospective study, 132 consecutive patients with ascites who underwent repeated abdominopelvic CT examinations performed within 7 days of each other were identified. These patients included 112 patients who received and 20 who did not receive IV contrast material at the initial CT examination. For each examination, we recorded the CT attenuation of the ascites. For the follow-up scan, the presence of delayed enhancement of ascites was defined as an increase in CT attenuation > 10 HU over baseline. The Fisher’s exact test, unpaired Student’s t test, and logistic regression were used to determine predictors of delayed enhancement of ascites. RESULTS A threshold increase in the attenuation of ascites by > 10 HU or more between the initial and follow-up CT examinations occurred only when IV contrast material was given with the initial examination. The increased attenuation was due to delayed contrast enhancement of ascites and occurred in 15 of the 112 patients (13%). Of the 16 patients scanned less than 1 day apart, 10 (63%) showed delayed enhancement of ascites. Delayed enhancement was not observed 3 or more days after IV contrast material administration. For each 1 mg/dL increase in serum creatinine level, the likelihood of delayed enhancement of ascites increased (odds ratio, 2.02; 95% CI, 1.11–3.69). Multivariate logistic regression showed that a short time interval between examinations (p < 0.001), increased serum creatinine level (p < 0.001), and presence of loculated ascites (p = < 0.01) were independent predictors of the magnitude of delayed enhancement of ascites. CONCLUSION Delayed contrast enhancement of ascites occurs commonly after recent prior IV contrast material administration and should not be mistaken for hemoperitoneum or proteinaceous fluid such as pus. PMID:19696286
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noal, Sabine; Clinical Research Department, Centre Francois Baclesse, Caen; Levy, Christelle
Purpose: Most patients with localized breast cancer (LBC) who take adjuvant chemotherapy (CT) complain of fatigue and a decrease in quality of life during or after radiotherapy (RT). The aim of this longitudinal study was to compare the impact of RT alone with that occurring after previous CT on quality of life. Methods and Materials: Fatigue (the main endpoint) and cognitive impairment were assessed in 161 CT-RT and 141 RT patients during RT and 1 year later. Fatigue was assessed with Functional Assessment of Cancer Therapy-General questionnaires, including breast and fatigue modules. Results: At baseline, 60% of the CT-RT patientsmore » expressed fatigue vs. 33% of the RT patients (p <0.001). Corresponding values at the end of RT were statistically similar (61% and 53%), and fatigue was still reported at 1 year by more than 40% of patients in both groups. Risk factors for long-term fatigue included depression (odds ratio [OR] = 6), which was less frequent in the RT group at baseline (16% vs. 28 %, respectively, p = 0.01) but reached a similar value at the end of RT (25% in both groups). Initial mild cognitive impairments were reported by RT (34 %) patients and CT-RT (24 %) patients and were persistent at 1 year for half of them. No biological disorders were associated with fatigue or cognitive impairment. Conclusions: Fatigue was the main symptom in LBC patients treated with RT, whether they received CT previously or not. The correlation of persistent fatigue with initial depressive status favors administering medical and psychological programs for LBC patients treated with CT and/or RT, to identify and manage this main quality-of-life-related symptom.« less
Fachinger, Patrick; Tini, Gabrielo Mauro; Grobholz, Rainer; Gambazzi, Franco; Fankhauser, Hans; Irani, Sarosh
2015-03-26
Pulmonary tularaemia is a very rare disease with only a small number of cases described in the literature. So far, to our knowledge, there exists no case report of pulmonary tularaemia where PET-CT scans and follow up CT scans are available. We present four consecutive cases of pulmonary tularaemia. All patients suffered from non-specific symptoms. All patients were referred to our institution with strong suspicions of malignancy, particularly lung cancer. Diagnosis of tularaemia was made by typical findings in the aspirate of EBUS guided fine needle aspiration (necrosis, epithelioid cell aggregation) and surgical biopsy respectively, and a positive serology. In three of the four cases, the diagnosis was confirmed by positive PCR results of the tissue. PET-CT scans obtained in all four cases were indistinguishable from lesions typically seen in patients suffering from lung cancer. One of the four patients suffered from recurrence of the disease after antibiotic treatment; also this patient finally recovered after initiation of a second antibiotic regimen. One case became asymptomatic spontaneously, but this patient still received an antibiotic treatment. In one case, a follow up CT scan was unchanged compared to the initial PET-CT scan; in all other cases, the lesions disappeared almost completely. Symptoms of patients suffering from pulmonary tularaemia are non-specific and can be of prolonged character. PET-CT scans in these cases are indistinguishable from lung cancer. The diagnosis can be established when typical findings in EBUS guided fine needle aspirates or surgical biopsies are found in combination with a positive serology. In most cases the lesions disappear in follow up CT scans after clinically successful treatment.
Computed tomography in the evaluation of penetrating neck trauma: a preliminary study.
Gracias, V H; Reilly, P M; Philpott, J; Klein, W P; Lee, S Y; Singer, M; Schwab, C W
2001-11-01
Penetrating neck trauma has traditionally been evaluated by surgical exploration and/or invasive diagnostic studies. We hypothesized that computed tomography (CT), used as an early diagnostic tool to accurately determine trajectory, would direct or eliminate further studies or procedures in stable patients with penetrating neck trauma. Retrospective case series. Academic, urban, level I trauma center. Hemodynamically stable patients without hard signs of vascular injury or aerodigestive violation who had sustained penetrating trauma to the neck. Patients underwent a spiral CT as an initial diagnostic study after initial evaluation in the trauma bay. Further invasive studies were directed by CT findings. Number of invasive studies performed. Twenty-three patients were identified during the 30-month period. Nineteen patients sustained gunshot wounds; 3, shotgun wounds; and 1, a stab wound. One patient died of a cranial gunshot wound. Three isolated zone I, 1 isolated zone II, 9 isolated zone III, and 10 multiple neck zone trajectories were evaluated. Thirteen patients were identified by CT to have trajectories remote from vital structures and required no further evaluation. Ten patients underwent angiography. Only 2 underwent bronchoscopy and esophagoscopy. Four patients were discharged from the emergency department; 7 other patients were discharged within 24 hours. No adverse patient events occurred before, during, or after CT scan. Computed tomography in stable selected patients with penetrating neck trauma appears safe. Invasive studies can often be eliminated from the diagnostic algorithm when CT demonstrates trajectories remote from vital structures. As a result, efficient evaluation and early discharge from the trauma bay or emergency department can be realized. Further prospective study of CT scan after penetrating neck trauma is needed.
Nowik, Patrik; Bujila, Robert; Poludniowski, Gavin; Fransson, Annette
2015-07-08
The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two-year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service.
NUT Midline Carcinoma in Elderly Patients: Usefulness of 18F-FDG PET/CT for Treatment Assessment.
Kawase, Takatsugu; Naka, Go; Kubota, Kazuo; Sakashita, Baku; Takeda, Yuichiro
2015-09-01
Nuclear protein in testis (NUT) midline carcinoma is a rare disease that generally arises in adolescents and young adults. However, we encountered a rare NUT midline carcinoma case in an elderly patient. F-2-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT) studies were performed before and during the treatment course. In this case, the initial PET/CT study revealed locoregional hypermetabolism in the mediastinal lesion. After then, the interim PET/CT study indicated a clear diminishing response to the initial treatment, whereas the residual masses were morphologically observable. Nuclear imaging may allow visualization of the therapeutic effect of antineoplastic therapies in both young and elderly patients.
Singh, Mansher; Ricci, Joseph A.
2015-01-01
Background: In patients with panfacial fractures and distorted anatomic landmarks of zygomatic and orbital complex, there is a risk of zygomaticomaxillary complex (ZMC) malpositioning even with the best efforts for surgical repair. This results in increased number of additional procedures to achieve accurate positioning. Methods: We describe the usage of intraoperative C-arm cone-beam computed tomographic (CT) scan for ZMC malpositioning in a representative patient with panfacial fractures. Results: We have successfully used intraoperative CT scan for ZMC malpositioning in 3 patients. The representative patient had ZMC malposition after the initial attempt of surgical repair without any intraoperative imaging. On using intraoperative CT scan during the next attempt, we were able to reposition the ZMC accurately. Conclusions: Intraoperative CT scan might improve the accuracy of ZMC positioning and decrease the chances of potential additional surgeries. In patients with distorted anatomical landmarks and panfacial fractures, it can be especially helpful toward correcting ZMC malposition. PMID:26301152
Joseph, Bellal; Friese, Randall S; Sadoun, Moutamn; Aziz, Hassan; Kulvatunyou, Narong; Pandit, Viraj; Wynne, Julie; Tang, Andrew; O'Keeffe, Terence; Rhee, Peter
2014-04-01
It is becoming a standard practice that any "positive" identification of a radiographic intracranial injury requires transfer of the patient to a trauma center for observation and repeat head computed tomography (RHCT). The purpose of this study was to define guidelines-based on each patient's history, physical examination, and initial head CT findings-regarding which patients require a period of observation, RHCT, or neurosurgical consultation. In our retrospective cohort analysis, we reviewed the records of 3,803 blunt traumatic brain injury patients during a 4-year period. We classified patients according to neurologic examination results, use of intoxicants, anticoagulation status, and initial head CT findings. We then developed brain injury guidelines (BIG) based on the individual patient's need for observation or hospitalization, RHCT, or neurosurgical consultation. A total of 1,232 patients had an abnormal head CT finding. In the BIG 1 category, no patients worsened clinically or radiographically or required any intervention. BIG 2 category had radiographic worsening in 2.6% of the patients. All patients who required neurosurgical intervention (13%) were in BIG 3. There was excellent agreement between assigned BIG and verified BIG. κ statistic is equal to 0.98. We have proposed BIG based on patient's history, neurologic examination, and findings of initial head CT scan. These guidelines must be used as supplement to good clinical examination while managing patients with traumatic brain injury. Prospective validation of the BIG is warranted before its widespread implementation. Epidemiologic study, level III.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mandapaka, A; Ghebremedhin, A; Farley, D
Purpose: To develop the methodology to evaluate the clinical performance of a Phase II Proton CT scanner Methods: Range errors on the order of 3%-5% constitute a major uncertainty in current charged particle treatment planning based on Hounsfield Unit (HU)-relative stopping power (RSP) calibration curves. Within our proton CT collaboration, we previously developed and built a Phase I proton CT scanner that provided a sensitive area of 9 cm (axial) × 18 cm (in-plane). This scanner served to get initial experience with this new treatment planning tool and to incorporate lessons learned into the next generation design. A Phase IImore » scanner was recently completed and is now undergoing initial performance testing. It will increase the proton acquisition rate and provide a larger detection area of 9 cm x 36 cm. We are now designing a comprehensive evaluation program to test the image quality, imaging dose, and range uncertainty associated with this scanner. The testing will be performed along the lines of AAPM TG 66. Results: In our discussion of the evaluation protocol we identified the following priorities. The image quality of proton CT images, in particular spatial resolution and low-density contrast discrimination, will be evaluated with the Catphan600 phantom. Initial testing showed that the Catphan uniformity phantom did not provide sufficient uniformity; it was thus replaced by a cylindrical water phantom. The imaging dose will be tested with a Catphan dose module, and compared to a typical cone beam CT dose for comparable image quality. Lastly, we developed a dedicated dosimetry range phantom based on the CIRS pediatric head phantom HN715. Conclusion: A formal evaluation of proton CT as a new tool for proton treatment planning is an important task. The availability of the new Phase II proton CT scanner will allow us to perform this task. This research is supported by the National Institute of Biomedical Imaging and Bioengineering of the NIH under award number R01EB013118. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.« less
New prospective 4D-CT for mitigating the effects of irregular respiratory motion
NASA Astrophysics Data System (ADS)
Pan, Tinsu; Martin, Rachael M.; Luo, Dershan
2017-08-01
Artifact caused by irregular respiration is a major source of error in 4D-CT imaging. We propose a new prospective 4D-CT to mitigate this source of error without new hardware, software or off-line data-processing on the GE CT scanner. We utilize the cine CT scan in the design of the new prospective 4D-CT. The cine CT scan at each position can be stopped by the operator when an irregular respiration occurs, and resumed when the respiration becomes regular. This process can be repeated at one or multiple scan positions. After the scan, a retrospective reconstruction is initiated on the CT console to reconstruct only the images corresponding to the regular respiratory cycles. The end result is a 4D-CT free of irregular respiration. To prove feasibility, we conducted a phantom and six patient studies. The artifacts associated with the irregular respiratory cycles could be removed from both the phantom and patient studies. A new prospective 4D-CT scanning and processing technique to mitigate the impact of irregular respiration in 4D-CT has been demonstrated. This technique can save radiation dose because the repeat scans are only at the scan positions where an irregular respiration occurs. Current practice is to repeat the scans at all positions. There is no cost to apply this technique because it is applicable on the GE CT scanner without new hardware, software or off-line data-processing.
Nilica, Bernhard; Waitz, Dietmar; Stevanovic, Vlado; Uprimny, Christian; Kendler, Dorota; Buxbaum, Sabine; Warwitz, Boris; Gerardo, Llanos; Henninger, Benjamin; Virgolini, Irene; Rodrigues, Margarida
2016-08-01
To determine the value of (68)Ga-DOTA-TOC and (18)F-FDG PET/CT for initial and follow-up evaluation of patients with neuroendocrine tumour (NET) treated with peptide receptor radionuclide therapy (PRRT). We evaluated 66 patients who had histologically proven NET and underwent both PRRT and three combined (68)Ga-DOTA-TOC and (18)F-FDG PET/CT studies. (68)Ga-DOTA-TOC PET/CT was performed before PRRT, 3 months after completion of PRRT and after a further 6 - 9 months. (18)F-FDG PET/CT was done within 2 months of (68)Ga-DOTA-TOC PET/CT. Follow-up ranged from 11.8 to 80.0 months (mean 34.5 months). All patients were (68)Ga-DOTA-TOC PET-positive initially and at follow-up after the first full PRRT cycle. Overall, 62 of the 198 (18)F-FDG PET studies (31 %) were true-positive in 38 of the 66 patients (58 %). Of the 66 patients, 28 (5 grade 1, 23 grade 2) were (18)F-FDG-negative initially and during follow-up (group 1), 24 (5 grade 1, 13 grade 2, 6 grade 3) were (18)F-FDG-positive initially and during follow-up (group 2), 9 patients (2 grade 1, 6 grade 2, 1 grade 3) were (18)F-FDG-negative initially but (18)F-FDG-positive during follow-up (group 3), and 5 patients (all grade 2) were (18)F-FDG-positive initially but (18)F-FDG-negative during follow-up (group 4).(18)F-FDG PET showed more and/or larger metastases than (68)Ga-DOTA-TOC PET in five patients of group 2 and four patients of group 3, all with progressive disease. In three patients with progressive disease who died during follow-up tumour SUVmax increased by 41 - 82 % from the first to the last follow-up investigation. In NET patients, the presence of (18)F-FDG-positive tumours correlates strongly with a higher risk of progression. Initially, patients with (18)F-FDG-negative NET may show (18)F-FDG-positive tumours during follow-up. Also patients with grade 1 and grade 2 NET may have (18)F-FDG-positive tumours. Therefore, (18)F-FDG PET/CT is a complementary tool to (68)Ga-DOTA-TOC PET/CT with clinical relevance for molecular investigation.
CT14QED parton distribution functions from isolated photon production in deep inelastic scattering
NASA Astrophysics Data System (ADS)
Schmidt, Carl; Pumplin, Jon; Stump, Daniel; Yuan, C.-P.
2016-06-01
We describe the implementation of quantum electrodynamic (QED) evolution at leading order (LO) along with quantum chromodynamic (QCD) evolution at next-to-leading order (NLO) in the CTEQ-TEA global analysis package. The inelastic contribution to the photon parton distribution function (PDF) is described by a two-parameter ansatz, coming from radiation off the valence quarks, and based on the CT14 NLO PDFs. Setting the two parameters to be equal allows us to completely specify the inelastic photon PDF in terms of the inelastic momentum fraction carried by the photon, p0γ, at the initial scale Q0=1.295 GeV . We obtain constraints on the photon PDF by comparing with ZEUS data [S. Chekanov et al. (ZEUS Collaboration), Phys. Lett. B 687, 16 (2010)] on the production of isolated photons in deep inelastic scattering, e p →e γ +X . For this comparison we present a new perturbative calculation of the process that consistently combines the photon-initiated contribution with the quark-initiated contribution. Comparison with the data allows us to put a constraint at the 90% confidence level of p0γ≲0.14 % for the inelastic photon PDF at the initial scale of Q0=1.295 GeV in the one-parameter radiative ansatz. The resulting inelastic CT14QED PDFs will be made available to the public. In addition, we also provide CT14QEDinc PDFs, in which the inclusive photon PDF at the scale Q0 is defined by the sum of the inelastic photon PDF and the elastic photon distribution obtained from the equivalent photon approximation.
NASA Technical Reports Server (NTRS)
Margasahayam, Ravi N.; Meyer, Karl A.; Nerolich, Shaun M.; Burton, Roy C.; Gosselin, Armand M.
2004-01-01
The Crawler Transporter (CT), designed and built for the Apollo Program in the 1960's and surpassing its initial operational life, has become an integral part of the Space Shuttle Program (SSP). The CT transports the Space Shuttle Vehicle (SSV) stack, atop the Mobile Launch Platform (MLP), from the Vehicle Assembly Building (VAB) to the launch pad. This support structure provides hydraulic jacking, leveling and load equalization for the 12 million pound stack on its 3.5-5.0 mile rollout to the launch pad. Major elements of the SSV, consisting of the orbiter, solid rocket boosters (SRB) and external tank (ET) have required fatigue analyses as part of the mission life certification. Compared to rollout vibration, the SSV sees relatively high vibration loads during launch, ascent, descent and landing phases of the mission. Although preliminary measured SRB vibration levels during rollout were of low amplitude and frequency, the duration of the rollout phase is typically high, from 5-6 hours. As part of an expanded mission life assessment, additional certification effort was initiated to define fatigue load spectra for rollout. This study addresses the CT vibration analyses in support of the rollout fatigue study. Structural models developed for modal and vibration analyses were used to identify unique CT, CT/MLP and CT/MLP/SRB vibration characteristics for comparison to instrumented rollout tests. Whereas the main structural and vibration characteristics of the SSV are well defined, minimum analytical and vibration test data on the Crawler Transporter were available. Unique vibration characteristics of the CT are attributable to the drive mechanism, hydraulic jacking system, structural framing and the CT-to-MLP support pad restraints. Initial tests performed on the CT/MLP/SRB configuration showed reasonable correlation with predicted mode shapes and frequencies.
Vittengl, Jeffrey R; Anna Clark, Lee; Thase, Michael E; Jarrett, Robin B
2017-07-01
Responders to acute-phase cognitive therapy (A-CT) for major depressive disorder (MDD) often relapse or recur, but continuation-phase cognitive therapy (C-CT) or fluoxetine reduces risks for some patients. We tested composite moderators of C-CT versus fluoxetine's preventive effects to inform continuation treatment selection. Responders to A-CT for MDD judged to be at higher risk for relapse due to unstable or partial remission (N=172) were randomized to 8 months of C-CT or fluoxetine with clinical management and assessed, free from protocol treatment, for 24 additional months. Pre-continuation-treatment characteristics that in survival analyses moderated treatments' effects on relapse over 8 months of continuation-phase treatment (residual symptoms and negative temperament) and on relapse/recurrence over the full observation period's 32 months (residual symptoms and age) were combined to estimate the potential advantage of C-CT versus fluoxetine for individual patients. Assigning patients to optimal continuation treatment (i.e., to C-CT or fluoxetine, depending on patients' pre-continuation-treatment characteristics) resulted in absolute reduction of relapse or recurrence risk by 16-21% compared to the other non-optimal treatment. Although these novel results require replication before clinical application, selecting optimal continuation treatment (i.e., personalizing treatment) for higher risk A-CT responders may decrease risks of MDD relapse and recurrence substantively. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhen, X; Chen, H; Zhou, L
2014-06-15
Purpose: To propose and validate a novel and accurate deformable image registration (DIR) scheme to facilitate dose accumulation among treatment fractions of high-dose-rate (HDR) gynecological brachytherapy. Method: We have developed a method to adapt DIR algorithms to gynecologic anatomies with HDR applicators by incorporating a segmentation step and a point-matching step into an existing DIR framework. In the segmentation step, random walks algorithm is used to accurately segment and remove the applicator region (AR) in the HDR CT image. A semi-automatic seed point generation approach is developed to obtain the incremented foreground and background point sets to feed the randommore » walks algorithm. In the subsequent point-matching step, a feature-based thin-plate spline-robust point matching (TPS-RPM) algorithm is employed for AR surface point matching. With the resulting mapping, a DVF characteristic of the deformation between the two AR surfaces is generated by B-spline approximation, which serves as the initial DVF for the following Demons DIR between the two AR-free HDR CT images. Finally, the calculated DVF via Demons combined with the initial one serve as the final DVF to map doses between HDR fractions. Results: The segmentation and registration accuracy are quantitatively assessed by nine clinical HDR cases from three gynecological cancer patients. The quantitative results as well as the visual inspection of the DIR indicate that our proposed method can suppress the interference of the applicator with the DIR algorithm, and accurately register HDR CT images as well as deform and add interfractional HDR doses. Conclusions: We have developed a novel and robust DIR scheme that can perform registration between HDR gynecological CT images and yield accurate registration results. This new DIR scheme has potential for accurate interfractional HDR dose accumulation. This work is supported in part by the National Natural ScienceFoundation of China (no 30970866 and no 81301940)« less
Young, Elisabeth S.; Reed, May J.; Pham, Tam N.; Gross, Joel A.; Taitsman, Lisa A.
2017-01-01
Background Older trauma patients often undergo computed tomography (CT) as part of the initial work-up. CT imaging can also be used opportunistically to measure bone density and assess osteoporosis. Methods In this retrospective cohort study, osteoporosis was ascertained from admission CT scans in women aged ≥65 admitted to the ICU for traumatic injury during a 3-year period at a single, safety-net, level 1 trauma center. Osteoporosis was defined by established CT-based criteria of average L1 vertebral body Hounsfield units <110. Evidence of diagnosis and/or treatment of osteoporosis was the primary outcome. Results The study cohort consisted of 215 women over a 3-year study period, of which 101 (47%) had evidence of osteoporosis by CT scan criteria. There were no differences in injury severity score, hospital length of stay, cost, or discharge disposition between groups with and without evidence of osteoporosis. Only 55 (59%) of the 94 patients with osteoporosis who survived to discharge had a documented osteoporosis diagnosis and/or corresponding evaluation/treatment plan. Conclusion Nearly half of older women admitted with traumatic injuries had underlying osteoporosis, but 41% had neither clinical recognition of this finding nor a treatment plan for osteoporosis. Admission for traumatic injury is an opportunity to assess osteoporosis, initiate appropriate intervention, and coordinate follow-up care. Trauma and acute care teams should consider assessment of osteoporosis in women who undergo CT imaging and provide a bridge to outpatient services. PMID:29234352
Compact Torus Fueling of the STOR-M Tokamak
NASA Astrophysics Data System (ADS)
Xiao, C.; Hirose, A.; Zawalski, W.; White, D.; Raman, R.; Decoste, R.; Gregory, B. C.; Martin, F.
1996-11-01
Tangential injection of accelerated compact torus (CT) has been performed on the STOR-M tokamak (R/a=46/12 cm, B_t<1 T, I_p<= 50 kA, barn_e=(0.5 - 1)×10^13 cm-3) using the University of Saskatchewan Compact Torus Injector (USCTI). The CT parameters are: m~=1 μg, v=120 km/sec, B=0.1 T and n=(2 - 4)×10^15 cm-3. After CT injection, the electron density in tokamak doubles and the poloidal β-value increases. Indications of reduction in the loop voltage and H_α emission level have also been observed. Currently, following efforts are being made: (a) to coat chromium on the electrode surface, (b) to increase the on-line baking temperature, and (c) to reduce the neutral gas load which follows the CT plasma. In addition, numerical calculation of CT motion in a tokamak magnetic field has been carried out. For horizontal injection, the initial CT magnetic dipole direction should be aligned with the CT velocity for deeper penetration. In the case of vertical injection, the CT trajectory is independent of the initial magnetic dipole direction and central penetration is facilitated by off-axis injection.
NASA Astrophysics Data System (ADS)
Christensen, Gary E.; Williamson, Jeffrey F.; Chao, K. S. C.; Miller, Michael I.; So, F. B.; Vannier, Michael W.
1997-10-01
This paper describes a new method to register serial, volumetric x-ray computed tomography (CT) data sets for tracking soft-tissue deformation caused by insertion of intracavity brachytherapy applicators to treat cervical cancer. 3D CT scans collected from the same patient with and without a brachytherapy applicator are registered to aid in computation of the radiation dose to tumor and normal tissue. The 3D CT image volume of pelvic anatomy with the applicator. Initial registration is accomplished by rigid alignment of the pelvic bones and non-rigid alignment of gray scale CT data and hand segmentations of the vagina, cervix, bladder, and rectum. A viscous fluid transformation model is used for non-rigid registration to allow for local, non-linear registration of the vagina, cervix, bladder, and rectum without disturbing the rigid registration of the bony pelvis and adjacent structures. Results are presented in which two 3D CT data sets of the same patient - imaged with and without a brachytherapy applicator - are registered.
Konecki, Dariusz; Pacho, Ryszard; Rowiński, Olgierd
2017-01-01
Summary Background Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. Material/Methods The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. Results The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. Conclusions CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding. PMID:29662594
Sivakumar, Parthipan; Jayaram, Deepak; Rao, Deepak; Dhileepan, Vignesh; Ahmed, Irfan; Ahmed, Liju
2016-12-01
Conventional Abrams biopsy shows low sensitivity in suspected malignant pleural disease. There are limited data on the improvement in sensitivity by adding in image guidance. This retrospective study compares the diagnostic sensitivity of Abrams biopsy using ultrasound guidance with CT-guided Tru-Cut biopsy in suspected malignant pleural disease. Data were collected from 2006 to 2012 of patients who underwent image-guided biopsies for suspected non-tuberculous pleural disease. Data were collected on the result of the initial biopsy and final patient diagnosis as of June 2015. Sixty-three patients underwent image-guided Abrams biopsy and 29 underwent CT-guided Tru-Cut biopsies. The sensitivity of Abrams was 71.43 % compared to 75 % in the CT-guided Tru-Cut group. Specificity was 100 % in both groups. Image-guided Abrams biopsies demonstrate comparable diagnostic sensitivity in malignant pleural disease to CT-guided Tru-Cut biopsy.
Norton, Elizabeth B.; Clements, John D.; Voss, Thomas G.; Cárdenas-Freytag, Lucia
2010-01-01
Prophylactic or therapeutic immunomodulation is an antigen-independent strategy that induces nonspecific immune system activation, thereby enhancing host defense to disease. In this study, we investigated the effect of prophylactic immunomodulation on the outcome of influenza virus infection using three bacterially derived immune-enhancing agents known for promoting distinct immunological profiles. BALB/c mice were treated nasally with either cholera toxin (CT), a mutant form of the CT-related Escherichia coli heat-labile enterotoxin designated LT(R192G), or CpG oligodeoxynucleotide. Mice were subsequently challenged with a lethal dose of influenza A/PR/8/34 virus 24 h after the last immunomodulation treatment and either monitored for survival or sacrificed postchallenge for viral and immunological analysis. Treatment with the three immunomodulators prevented or delayed mortality and weight loss, but only CT and LT(R192G) significantly reduced initial lung viral loads as measured by plaque assay. Analysis performed 4 days postinfection indicated that prophylactic treatments with CT, LT(R192G), or CpG resulted in significantly increased numbers of CD4 T cells, B cells, and dendritic cells and altered costimulatory marker expression in the airways of infected mice, coinciding with reduced expression of pulmonary chemokines and the appearance of inducible bronchus-associated lymphoid tissue-like structures in the lungs. Collectively, these results suggest that, despite different immunomodulatory mechanisms, CT, LT(R192G), and CpG induce an initial inflammatory process and enhance the immune response to primary influenza virus challenge while preventing potentially damaging chemokine expression. These studies provide insight into the immunological parameters and immune modulation strategies that have the potential to enhance the nonspecific host response to influenza virus infection. PMID:20053748
Renner, Fritz; Jarrett, Robin B.; Vittengl, Jeffrey R.; Barrett, Marna S.; Clark, Lee Anna; Thase, Michael E.
2012-01-01
Background The degree to which interpersonal problems of depressed patients improve over the course of cognitive therapy (CT) and relate to the quality of the therapeutic alliance and to symptom improvement, remain unclear. Methods We analyzed data of adult outpatients (N = 523) with major depressive disorder participating in a clinical trial to determine the factor structure of the Inventory of Interpersonal Problems-Circumplex (IIP-C) and to relate the observed factor scores to the quality of the therapeutic alliance and symptom improvement over the course of CT. Patients received 16–20 sessions protocol (50–60 minutes each) of individual CT according to the treatment manual by Beck et al. (1979). Results We found a three-factor structure (interpersonal distress, agency, and communion) of interpersonal problems. Interpersonal distress decreased (d = .90), but interpersonal style did not change substantively during CT (communion d = .03; agency d = .14). High initial agency scores related negatively to the therapeutic alliance (β = −.12), whereas high initial communion scores related positively to the therapeutic alliance (β = .15). Elevated pre-treatment interpersonal distress scores were related to both weaker therapeutic alliances (β = .13) and higher symptom levels throughout treatment (β = .10). Limitations All patients in this study had recurrent MDD and it is therefore uncertain whether the results would generalize to patients with other psychiatric disorders. Conclusions This study supports the use of the IIP-C as a comprehensive measure of patients' interpersonal style and interpersonal distress. The IIP-C measured before CT showed some predictive validity with respect to therapeutic alliance measured at the midpoint and therapy outcome. The clinical importance of these findings is discussed. PMID:22306232
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farjam, R; Tyagi, N; Veeraraghavan, H
Purpose: To develop image-analysis algorithms to synthesize CT with accurate electron densities for MR-only radiotherapy of head & neck (H&N) and pelvis anatomies. Methods: CT and 3T-MRI (Philips, mDixon sequence) scans were randomly selected from a pool of H&N (n=11) and pelvis (n=12) anatomies to form an atlas. All MRIs were pre-processed to eliminate scanner and patient-induced intensity inhomogeneities and standardize their intensity histograms. CT and MRI for each patient were then co-registered to construct CT-MRI atlases. For more accurate CT-MR fusion, bone intensities in CT were suppressed to improve the similarity between CT and MRI. For a new patient,more » all CT-MRI atlases are deformed onto the new patients’ MRI initially. A newly-developed generalized registration error (GRE) metric was then calculated as a measure of local registration accuracy. The synthetic CT value at each point is a 1/GRE-weighted average of CTs from all CT-MR atlases. For evaluation, the mean absolute error (MAE) between the original and synthetic CT (generated in a leave-one-out scheme) was computed. The planning dose from the original and synthetic CT was also compared. Results: For H&N patients, MAE was 67±9, 114±22, and 116±9 HU over the entire-CT, air and bone regions, respectively. For pelvis anatomy, MAE was 47±5 and 146±14 for the entire and bone regions. In comparison with MIRADA medical, an FDA-approved registration tool, we found that our proposed registration strategy reduces MAE by ∼30% and ∼50% over the entire and bone regions, respectively. GRE-weighted strategy further lowers MAE by ∼15% to ∼40%. Our primary dose calculation also showed highly consistent results between the original and synthetic CT. Conclusion: We’ve developed a novel image-analysis technique to synthesize CT for H&N and pelvis anatomies. Our proposed image fusion strategy and GRE metric help generate more accurate synthetic CT using locally more similar atlases (Support: Philips Healthcare). The research is supported by Philips HealthCare.« less
Öğrenci, Ahmet; Koban, Orkun; Ekşi, Murat; Yaman, Onur; Dalbayrak, Sedat
2017-01-01
AIM: This study aimed to make a retrospective analysis of pediatric patients with head traumas that were admitted to one hospital setting and to make an analysis of the patients for whom follow-up CT scans were obtained. METHODS: Pediatric head trauma cases were retrospectively retrieved from the hospital’s electronic database. Patients’ charts, CT scans and surgical notes were evaluated by one of the authors. Repeat CT scans for operated patients were excluded from the total number of repeat CT scans. RESULTS: One thousand one hundred and thirty-eight pediatric patients were admitted to the clinic due to head traumas. Brain CT scan was requested in 863 patients (76%) in the cohort. Follow-up brain CT scans were obtained in 102 patients. Additional abnormal finding requiring surgical intervention was observed in only one patient (isolated 4th ventricle hematoma) on the control CTs (1% of repeat CT scans), who developed obstructive hydrocephalus. None of the patients with no more than 1 cm epidural hematoma in its widest dimension and repeat CT scans obtained 1.5 hours after the trauma necessitated surgery. CONCLUSION: Follow-up CT scans changed clinical approach in only one patient in the present series. When ordering CT scan in the follow-up of pediatric traumas, benefits and harms should be weighted based upon time interval from trauma onset to initial CT scan and underlying pathology. PMID:29104682
Eshghi, Naghmehossadat; Lundeen, Tamara F; MacKinnon, Lea; Avery, Ryan; Kuo, Phillip H
2018-05-01
An 85-year-old man with stage IIIA Merkel cell carcinoma of the left arm was initially treated with local excision and axillary node dissection followed by radiation therapy. Eight months after surgery, whole-body FDG PET/CT demonstrated intensely hypermetabolic hepatic metastases and abdominal lymphadenopathy. Given his age and comorbidities, he was considered a poor candidate for chemotherapy, and therefore the novel programmed cell death ligand 1 inhibitor avelumab was initiated. FDG PET/CT after 4 cycles showed complete resolution of hepatic and nodal metastases. Whole-body FDG PET/CT can be used for monitoring response of multisystem metastases from Merkel cell carcinoma to active immunotherapy.
Allmendinger, Thomas
2017-01-01
Objective Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. Materials and Methods In total, 15 children (median age 19 months, range 6 months–8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Results Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Conclusion Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children. PMID:28860904
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schreibmann, Eduard, E-mail: eschre2@emory.edu; Schuster, David M.; Rossi, Peter J.
Purpose: {sup 18}F-Fluciclovine (anti-1-amino-3-[{sup 18}F]fluorocyclobutane-1-carboxylic acid) is a novel positron emission tomography (PET)/computed tomography (CT) radiotracer that has demonstrated utility for detection of prostate cancer. Our goal is to report the initial results from a randomized controlled trial of the integration of {sup 18}F-fluciclovine PET-CT into treatment planning for defining prostate bed and lymph node target volumes. Methods and Materials: We report our initial findings from a cohort of 41 patients, of the first enrolled on a randomized controlled trial, who were randomized to the {sup 18}F-fluciclovine arm. All patients underwent {sup 18}F-fluciclovine PET-CT for the detection of metabolic abnormalitiesmore » and high-resolution CT for treatment planning. The 2 datasets were registered first by use of a rigid registration. If soft tissue displacement was observable, the rigid registration was improved with a deformable registration. Each {sup 18}F-fluciclovine abnormality was segmented as a percentage of the maximum standard uptake value (SUV) within a small region of interest around the lesion. The percentage best describing the SUV falloff was integrated in planning by expanding standard target volumes with the PET abnormality. Results: In 21 of 55 abnormalities, a deformable registration was needed to map the {sup 18}F-fluciclovine activity into the simulation CT. The most selected percentage was 50% of maximum SUV, although values ranging from 15% to 70% were used for specific patients, illustrating the need for a per-patient selection of a threshold SUV value. The inclusion of {sup 18}F-fluciclovine changed the planning volumes for 46 abnormalities (83%) of the total 55, with 28 (51%) located in the lymph nodes, 11 (20%) in the prostate bed, 10 (18%) in the prostate, and 6 (11%) in the seminal vesicles. Only 9 PET abnormalities were fully contained in the standard target volumes based on the CT-based segmentations and did not necessitate expansion. Conclusions: The use of {sup 18}F-fluciclovine in postprostatectomy radiation therapy planning was feasible and led to augmentation of the target volumes in the majority (30 of 41) of the patients studied.« less
Clinical values of (18) F-FDG PET/CT in oral cavity cancer with dental artifacts on CT or MRI.
Hong, Hye Ran; Jin, Soyoung; Koo, Hyun Jung; Roh, Jong-Lyel; Kim, Jae Seung; Cho, Kyung-Ja; Choi, Seung-Ho; Nam, Soon Yuhl; Kim, Sang Yoon
2014-11-01
2a To investigate the role of (18) F-FDG PET/CT in tumor staging, extent, and volume measurements in oral cavity squamous cell carcinoma (OSCC) patients with/without dental artifacts on CT or MRI. This study was conducted in 63 consecutive patients with OSCC who received initial workups including (18) F-FDG PET/CT and MRI. The results of the imaging modalities were compared to those of pathology, using McNemar's test and the paired t-test. Thirty-seven patients (59%) had dental or metallic artifacts obscuring primary tumors. (18) F-FDG PET/CT scanning was superior to MRI in tumor staging (weighted κ = 0.870 vs. 0.518, P = 0.004) in patients with dental artifacts. In addition, (18) F-FDG PET/CT scans were more specific than MRI in detecting sublingual gland (P = 0.014) and mouth floor (P = 0.011) involvement. In patients with dental artifacts, there was a significant discrepancy between primary tumor volume (PTV) measured by pathology and MRI (P = 0.018), but not between PTV measured from pathology and (18) F-FDG PET/CT at SUV2.5 (P = 0.245), which showed the highest intraclass correlation coefficient value (0.860). (18) F-FDG PET/CT scans provide accurate tumor staging and volume measurements in OSCC patients with CR/MRI dental artifacts, leading to improved preoperative planning. 2b CONDENSED ABSTRACT This study evaluated the clinical value of (18) F-FDG PET/CT in 63 patients with oral cavity cancers. In 37 (59%) patients with dental artifacts on CT/MRI, (18) F-FDG PET/CT showed superior results compared to MRI in tumor staging and represented the highest intraclass correlation coefficient value to tumor volume determined by pathology. © 2014 Wiley Periodicals, Inc.
Shephard, Mark D; Mazzachi, Beryl C; Watkinson, Les; Shephard, Anne K; Laurence, Caroline; Gialamas, Angela; Bubner, Tanya
2009-01-01
From September 2005 to February 2007 the Australian Government funded the Point of Care Testing (PoCT) in General Practice Trial, a multi-centre, cluster randomised controlled trial to determine the safety, clinical effectiveness, cost-effectiveness and satisfaction of PoCT in General Practice. In total, 53 practices (23 control and 30 intervention) based in urban, rural or remote locations across three states (South Australia [SA], New South Wales [NSW] and Victoria [VIC]) participated in the Trial. Control practices had pathology testing performed by their local laboratory, while intervention practices conducted pathology testing by PoCT. In total, 4968 patients (1958 control and 3010 intervention) participated in the Trial. The point-of-care (PoC) tests performed by intervention practices were: haemoglobin A1c (HbA1c) and urine albumin:creatinine ratio (ACR) on patients with diabetes, total cholesterol, triglyceride and high density lipoprotein (HDL) cholesterol on patients with hyperlipidaemia, and international normalised ratio (INR) on patients on anticoagulant therapy. Three PoCT devices measured these tests: the Siemens DCA 2000 (Siemens HealthCare Diagnostics, Melbourne, VIC, Australia) for HbA1c and urine ACR; Point of Care Diagnostics Cholestech LDX analyser (Point of Care Diagnostics; Sydney, NSW, Australia) for lipids; and the Roche CoaguChek S (Roche Diagnostics; Sydney, NSW, Australia) for INR. Point-of-care testing in the General Practice Trial was underpinned by a quality management framework which included an on-going training and competency program for PoCT device operators. This article describes the design, implementation and results of the training and competency program. An education and training resource package was developed for the Trial consisting of a training manual, a set of A3 laminated posters and a CD ROM. Five initial training workshops were held for intervention practices from each geographic region between August and October 2005 at three centres - Adelaide (SA), Bendigo (VIC) and Dubbo (NSW). These workshops combined theoretical training in the principles and practice of PoCT with 'hands on' practical training delivered in interactive small group sessions. At the completion of training, practice staff undertook a written and practical competency assessment and received a certificate of competency as a qualified device operator. Following each initial training workshop, practice staff completed a short satisfaction survey. Five refresher training workshops covering all geographic regions were delivered during late August 2006, coinciding with the 12 month point of the live phase of the Trial. At the completion of the Trial in February 2007, device operators completed a further questionnaire. Sixty device operators from 31 practices completed training and competency assessment as part of the Initial Training Workshop series. A further 20 device operators from 12 of the practices were trained in the 12 month period after the initial workshops; 19 of these staff were from rural or remote practices. In total 80 device operators comprising 74 practice staff and six GPs from 31 practices were trained and received competency certificates as part of Trial. In all, 19 device operators left the Trial either through personal resignation from an existing practice or because their practice withdrew from the Trial; the majority (84%) were from rural and remote practices. A total of 42 device operators from 25 practices attended refresher training in the second half of 2006. Results from the satisfaction questionnaire completed by device operators following the initial training workshops showed there was unanimous agreement that the posters were useful for the conduct of daily PoCT and practical training in small groups was satisfactory as a training method. The quality and appropriateness of the PoCT training resources and the workshop overall was rated as either good or excellent by all respondents (100% and 78%, respectively). The responses by device operators to the post-Trial satisfaction questionnaire found a high level of satisfaction with PoCT across all geographic regions. Device operators from remote practices had the highest satisfaction levels for quality of training, usefulness of the training manual, ease of use of devices, confidence in the accuracy of PoCT results and preference for PoCT over laboratory testing. The usefulness of the posters for conducting PoCT achieved the highest satisfaction rating among operators from all three geographic regions. However the highest staff turnover rates and the highest number of requests for training of additional staff were from rural and remote practices. The methods established for the implementation and delivery of training and competency assessment for the PoCT in General Practice Trial were appropriate and effective. Results of the evaluation showed rural and remote practices have a greater need for training and support compared to their urban counterparts and may require more flexible training options to cater for much higher rates of staff turnover.
Automated segmentation of murine lung tumors in x-ray micro-CT images
NASA Astrophysics Data System (ADS)
Swee, Joshua K. Y.; Sheridan, Clare; de Bruin, Elza; Downward, Julian; Lassailly, Francois; Pizarro, Luis
2014-03-01
Recent years have seen micro-CT emerge as a means of providing imaging analysis in pre-clinical study, with in-vivo micro-CT having been shown to be particularly applicable to the examination of murine lung tumors. Despite this, existing studies have involved substantial human intervention during the image analysis process, with the use of fully-automated aids found to be almost non-existent. We present a new approach to automate the segmentation of murine lung tumors designed specifically for in-vivo micro-CT-based pre-clinical lung cancer studies that addresses the specific requirements of such study, as well as the limitations human-centric segmentation approaches experience when applied to such micro-CT data. Our approach consists of three distinct stages, and begins by utilizing edge enhancing and vessel enhancing non-linear anisotropic diffusion filters to extract anatomy masks (lung/vessel structure) in a pre-processing stage. Initial candidate detection is then performed through ROI reduction utilizing obtained masks and a two-step automated segmentation approach that aims to extract all disconnected objects within the ROI, and consists of Otsu thresholding, mathematical morphology and marker-driven watershed. False positive reduction is finally performed on initial candidates through random-forest-driven classification using the shape, intensity, and spatial features of candidates. We provide validation of our approach using data from an associated lung cancer study, showing favorable results both in terms of detection (sensitivity=86%, specificity=89%) and structural recovery (Dice Similarity=0.88) when compared against manual specialist annotation.
Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Flohr, Thomas; Leidecker, Christianne; Groden, Christoph; Scharf, Johann; Henzler, Thomas
2015-01-01
Objectives To prospectively intra-individually compare image quality of a 3rd generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. Methods 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3rd generation DSCT. CTDIvol identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3rd-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. Results Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (p<0.05). Mean SNR was significantly higher in all spiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*Bonferroni0.05<0.0024). Subjective image quality improved with increasing IR levels. Conclusion Combination of 3rd-generation DSCT spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels. PMID:26288186
18F-FDG PET/CT Imaging of Hidradenocarcinoma Arising From Preexisting Hidradenoma of the Knee.
Patel, Tirth V; Oldan, Jorge
2018-01-01
Malignant tumors of the sweat glands are exceedingly rare and aggressive tumors. We present here a case of a 60-year-old man with a malignant hidradenocarcinoma that developed in a background of preexisting benign hidradenoma on the lateral aspect of the knee that was initially resected, but rapidly recurred with associated inguinal lymphadenopathy. F-FDG PET/CT was performed as part of preoperative staging, which demonstrated abnormal inguinal lymph nodes and metastatic disease to the lungs. FDG PET/CT can play an invaluable role in the initial staging and follow-up of this rare malignancy.
Does CT help in predicting preepiglottic space invasion in laryngeal carcinoma?
Bozkurt, Gülpembe; Ünsal, Özlem; Çelebi, İrfan; Ayhan, Burak; Guliyev, Umman; Akova, Pınar; Başak, Tülay; Coşkun, Berna Uslu
2018-06-01
Evaluating preepiglottic space involvement in laryngeal cancer by CT may lead misinterpretation. We sought to understand the causes of misinterpretation in evaluating the preepiglottic space by CT and assessed the effects of misinterpretation in treatment plans of patients with laryngeal squamous cell carcinomas. Specimen histopathology reports of 102 (99 male, 3 female) patients who underwent total or partial laryngectomy due to supraglottic and/or transglottic laryngeal carcinoma were reviewed. Neck CTs were also re-assessed for preepiglottic space involvement by three radiologists. The initial surgical treatment choices were re-examined according to the current radiological evaluation in combination with pathological results of the specimens and physical examination findings in the patients. Interobserver agreement regarding image interpretation was based on a kappa analysis. The interclass correlation coefficient in predicting preepiglottic space invasion was 0.74; this was considered 'good.' Among the three radiologists, sensitivity, specificity, accuracy of CT in detecting preepiglottic space involvement were 86-93%, 75-93%, and 77-93%, respectively, while the negative and positive predictive values were 97-98% and 38-50%, respectively. Given the previous treatments applied, false-positive diagnoses for PES involvement resulted in overtreatment in 2.9% of cases. False-negative diagnoses of PES involvement (1.9% of cases) did not result in any undertreatment. Although CT is a practical and inexpensive imaging tool for evaluating laryngeal carcinomas, the PPV of CT in assessing preepiglottic space invasion, especially in advanced tumors, is low and may lead to overtreatment. Copyright © 2017 Elsevier B.V. All rights reserved.
18F-FDG uptake and its clinical relevance in primary gastric lymphoma.
Yi, Jun Ho; Kim, Seok Jin; Choi, Joon Young; Ko, Young Hyeh; Kim, Byung-Tae; Kim, Won Seog
2010-06-01
We studied the clinical relevance of (18)F-fluorodeoxyglucose ((18)F-FDG) uptake in patients with primary gastric lymphoma underwent positron emission tomography (PET)/ computed tomography (CT) scan. Forty-two patients with primary gastric lymphoma were analysed: 32 diffuse large B-cell lymphomas (DLBCL) and 10 extranodal marginal zone B-cell lymphomas of mucosa-associated lymphoid tissue (MALT lymphomas). The PET/CT scans were compared with clinical and pathologic features, and the results of CT and endoscopy. Nine patients were up-staged based on the results of their PET/CT scan compared to CT (seven DLBCLs, two MALT lymphomas) while six patients were down-staged by the PET/CT scan. The standard uptake value (SUV) was used as an indicator of a lesion with a high metabolic rate. The high SUVmax group, defined as an SUVmax >or= median value, was significantly associated with an advanced Lugano stage (p < 0.001). Three patients with DLBCL, who showed an initially high SUVmax, died of disease progression. Among 24 patients for whom follow-up PET/CT scan with endoscopy was performed, 11 patients with ulcerative or mucosal lesions showed residual (18)F-FDG uptake. All of these gastric lesions were grossly and pathologically benign lesions without evidence of lymphoma cells. In conclusion, PET/CT scan can be used in staging patients with primary gastric lymphoma; however, the residual (18)F-FDG uptake observed during follow-up should be interpreted cautiously and should be combined with endoscopy and multiple biopsies of the stomach. (c) 2009 John Wiley & Sons, Ltd.
Exploring User Learnability and Learning Performance in an App for Depression: Usability Study
Montague, Enid; Lattie, Emily G; Schueller, Stephen M; Kwasny, Mary J; Mohr, David C
2017-01-01
Background Mental health apps tend to be narrow in their functioning, with their focus mostly being on tracking, management, or psychoeducation. It is unclear what capability such apps have to facilitate a change in users, particularly in terms of learning key constructs relating to behavioral interventions. Thought Challenger (CBITs, Chicago) is a skill-building app that engages users in cognitive restructuring, a core component of cognitive therapy (CT) for depression. Objective The purpose of this study was to evaluate the learnability and learning performance of users following initial use of Thought Challenger. Methods Twenty adults completed in-lab usability testing of Thought Challenger, which comprised two interactions with the app. Learnability was measured via completion times, error rates, and psychologist ratings of user entries in the app; learning performance was measured via a test of CT knowledge and skills. Nonparametric tests were conducted to evaluate the difference between individuals with no or mild depression to those with moderate to severe depression, as well as differences in completion times and pre- and posttests. Results Across the two interactions, the majority of completion times were found to be acceptable (5 min or less), with minimal errors (1.2%, 10/840) and successful completion of CT thought records. Furthermore, CT knowledge and skills significantly improved after the initial use of Thought Challenger (P=.009). Conclusions The learning objectives for Thought Challenger during initial uses were successfully met in an evaluation with likely end users. The findings therefore suggest that apps are capable of providing users with opportunities for learning of intervention skills. PMID:28801301
Abdomen/pelvis computed tomography in staging of pediatric Hodgkin Lymphoma: is it always necessary?
Farruggia, Piero; Puccio, Giuseppe; Sala, Alessandra; Todesco, Alessandra; Terenziani, Monica; Mura, Rosamaria; D'Amico, Salvatore; Casini, Tommaso; Mosa, Clara; Pillon, Marta; Boaro, Maria Paola; Bottigliero, Gaetano; Burnelli, Roberta; Consarino, Caterina; Fedeli, Fausto; Mascarin, Maurizio; Perruccio, Katia; Schiavello, Elisabetta; Trizzino, Angela; Ficola, Umberto; Garaventa, Alberto; Rossello, Mario
2016-09-01
The purpose of the study was to determine if abdomen/pelvis computed tomography (CT) can be safety omitted in the initial staging of a subgroup of children affected by Hodgkin Lymphoma (HL). Every participating center of A.I.E.O.P (Associazione Italiana di Ematologia ed Oncologia Pediatrica) sent local staging reports of 18F-fluorodeoxyglucose positron emission tomography (PET) and abdominal ultrasound (US) along with digital images of staging abdomen/pelvis CT to the investigation center where the CT scans were evaluated by an experienced pediatric radiologist. The local radiologist who performed the US was unaware of local CT and PET reports (both carried out after US), and the reviewer radiologist examining the CT images was unaware of local US, PET and CT reports. A new abdominal staging of 123 patients performed on the basis of local US report, local PET report, and centralized CT report was then compared to a simpler staging based on local US and PET. No additional lesion was discovered by CT in patients with abdomen/pelvis negativity in both US and PET or isolated spleen positivity in US (or US and PET), and so it seems that in the initial staging, abdomen/pelvis CT can be safety omitted in about 1/2 to 2/3 of children diagnosed with HL. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
SparseCT: interrupted-beam acquisition and sparse reconstruction for radiation dose reduction
NASA Astrophysics Data System (ADS)
Koesters, Thomas; Knoll, Florian; Sodickson, Aaron; Sodickson, Daniel K.; Otazo, Ricardo
2017-03-01
State-of-the-art low-dose CT methods reduce the x-ray tube current and use iterative reconstruction methods to denoise the resulting images. However, due to compromises between denoising and image quality, only moderate dose reductions up to 30-40% are accepted in clinical practice. An alternative approach is to reduce the number of x-ray projections and use compressed sensing to reconstruct the full-tube-current undersampled data. This idea was recognized in the early days of compressed sensing and proposals for CT dose reduction appeared soon afterwards. However, no practical means of undersampling has yet been demonstrated in the challenging environment of a rapidly rotating CT gantry. In this work, we propose a moving multislit collimator as a practical incoherent undersampling scheme for compressed sensing CT and evaluate its application for radiation dose reduction. The proposed collimator is composed of narrow slits and moves linearly along the slice dimension (z), to interrupt the incident beam in different slices for each x-ray tube angle (θ). The reduced projection dataset is then reconstructed using a sparse approach, where 3D image gradients are employed to enforce sparsity. The effects of the collimator slits on the beam profile were measured and represented as a continuous slice profile. SparseCT was tested using retrospective undersampling and compared against commercial current-reduction techniques on phantoms and in vivo studies. Initial results suggest that SparseCT may enable higher performance than current-reduction, particularly for high dose reduction factors.
Compact Torus Injection Experiments on the H.I.T. teststand and the JFT-2M tokamak
NASA Astrophysics Data System (ADS)
Fukumoto, Naoyuki; Fujiwara, Makoto; Kuramoto, Keiji; Ageishi, Masaya; Nagata, Masayoshi; Uyama, Tadao; Ogawa, Hiroaki; Kasai, Satoshi; Hasegawa, Kouichi; Shibata, Takatoshi
1997-11-01
A spheromak-type compact torus (CT) acceleration and injection experiment has been carried out using the Himeji Institute of Technology Compact Torus Injector (HIT-CTI). We investigate the possibility of refueling, density control, current drive, and edge electric field control of tokamak plasmas by means of CT injection. The HIT-CTI produces a CT with a speed of 200 km/s and a density of 1× 10^21m-3. We have constructed new electrodes and power supplies, and will install the HIT-CTI on the JFT-2M tokamak at JAERI in Autumn 1997. The outer electrode serves as a common ground for both the formation bank (144μF, 20kV) and the acceleration bank (92.4μF, 40kV). If the external toroidal field of the tokamak is applied across the CT acceleration region, the CT kinetic energy might decrease during penetration into the field lines joining the inner and outer electrode. This could result in the CT not being able to reach the core of the tokamak plasma. Determining the optimum position of the inner electrode is one of the near term goals of this research. We will present magnetic probe, He-Ne interferometer and fast framing camera data from experiments at H.I.T., where a CT was accelerated into a transverse field. We will also present initial results from the operation of the HIT-CTI on the JFT-2M tokamak.
Dedicated Cone-Beam CT System for Extremity Imaging
Al Muhit, Abdullah; Zbijewski, Wojciech; Thawait, Gaurav K.; Stayman, J. Webster; Packard, Nathan; Senn, Robert; Yang, Dong; Foos, David H.; Yorkston, John; Siewerdsen, Jeffrey H.
2014-01-01
Purpose To provide initial assessment of image quality and dose for a cone-beam computed tomographic (CT) scanner dedicated to extremity imaging. Materials and Methods A prototype cone-beam CT scanner has been developed for imaging the extremities, including the weight-bearing lower extremities. Initial technical assessment included evaluation of radiation dose measured as a function of kilovolt peak and tube output (in milliampere seconds), contrast resolution assessed in terms of the signal difference–to-noise ratio (SDNR), spatial resolution semiquantitatively assessed by using a line-pair module from a phantom, and qualitative evaluation of cadaver images for potential diagnostic value and image artifacts by an expert CT observer (musculoskeletal radiologist). Results The dose for a nominal scan protocol (80 kVp, 108 mAs) was 9 mGy (absolute dose measured at the center of a CT dose index phantom). SDNR was maximized with the 80-kVp scan technique, and contrast resolution was sufficient for visualization of muscle, fat, ligaments and/or tendons, cartilage joint space, and bone. Spatial resolution in the axial plane exceeded 15 line pairs per centimeter. Streaks associated with x-ray scatter (in thicker regions of the patient—eg, the knee), beam hardening (about cortical bone—eg, the femoral shaft), and cone-beam artifacts (at joint space surfaces oriented along the scanning plane—eg, the interphalangeal joints) presented a slight impediment to visualization. Cadaver images (elbow, hand, knee, and foot) demonstrated excellent visibility of bone detail and good soft-tissue visibility suitable to a broad spectrum of musculoskeletal indications. Conclusion A dedicated extremity cone-beam CT scanner capable of imaging upper and lower extremities (including weight-bearing examinations) provides sufficient image quality and favorable dose characteristics to warrant further evaluation for clinical use. © RSNA, 2013 Online supplemental material is available for this article. PMID:24475803
The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.
Badakhshi, Harun; Graf, Reinhold; Prasad, Vikas; Budach, Volker
2014-06-25
18 F-fluoro-ethyl-tyrosine PET is gaining more indications in the field of oncology. We investigated the potentials of usage of FET-PET/CT in addition to MRI for definition of gross tumor volume (GTV) in stereotactic radiotherapy of lesions of skull base. We included in a prospective setting 21 cases. An MRI was performed, completed by FET PET/CT. Different GTV's were defined based on respective imaging tools: 1. GTVMRI, 2. GTV MRI /CT, 3. GTV composit (1 + 2), and GTVPET = GTV Boost. Lesions could be visualised by MRI and FET-PET/CT in all patients. FET tracer enhancement was found in all cases. Skull base infiltration by these lesions was observed by MRI, CT (PET/CT) and FET-PET (PET/CT) in all patients. Totally, brain tissue infiltration was seen in 10 patients. While, in 7 (out 10) cases, MRI and CT (from PET/CT) were indicating brain infiltration, FET-PET could add additional information regarding infiltrative behaviour: in 3 (out 10) patients, infiltration of the brain was displayed merely in FET-PET. An enlargement of GTVMRI/CT due to the FET-PET driven information, which revealed GTVcomposite , was necessary in 7 cases,. This enlargement was significant by definition (> 10% of GTVMRI/CT). The mean PET-effect on GTV counted for 1 ± 4 cm3. The restricted boost fields were based mainly on the GTVPET volume. In mean, about 8.5 cm3 of GTVMRI/CT, which showed no FET uptake, were excluded from target volume. GTV boost driven by only-PET-activity, was in mean by 33% smaller than the initial large treatment field, GTV composite, for those cases received boost treatment. FET-PET lead to significant (>10%) changes in the initial treatment fields in 11/21 patients and showed additional tumour volume relevant for radiation planning in 6/21 cases, and led to a subsequent decrease of more than 10% of the initial volumes for the boost fields. The implementation of FET PET into the planning procedures showed a benefit in terms of accurate definition of skull base lesions as targets for Image-guided stereotactic Radiotherapy. This has to be investigated prospectively in larger cohorts.
Bujila, Robert; Poludniowski, Gavin; Fransson, Annette
2015-01-01
The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two‐year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service PACS numbers: 87.57.C‐, 87.57.N‐, 87.57.Q‐ PMID:26219012
Microstructural examination of
NASA Astrophysics Data System (ADS)
Fukuoka, C.; Yoshizawa, H.; Nakagawa, Y. G.; Lapides, M. E.
1993-10-01
Fatigue tests were performed to examine how microstructural conditioning influences crack initiation and propagation in SA508 class 3 low-carbon steel. A 3-mm-long crack was introduced in compact tension (CT) fatigue test specimens under four different loads in order to obtain crack tip plastic zones at different stress intensity factor ranges, ΔK = 18, 36, 54, and 72 MPa√m. The microstructure of the plastic zones around the crack tip were examined by trans- mission electron microscopy (TEM) and selected area electron diffraction (SAD). Micro- orientation of the dislocation cells in the plastic zones of all of the CT samples increased to 4 deg from the level of an as-received sample. Four-point bending fatigue tests were performed for plate shape samples with a large cyclic strain range. The SAD value of the bending samples was also 4 deg in the damaged area where cracks already initiated at an early stage of the fatigue process. These test results indicate that the microstructural conditioning is a prerequisite for the fatigue crack initiation and propagation in SA508. These observations may lead to better under- standing of how fatigue initiation processes transit to cracks.
Blumfield, Einat; Zember, Jonathan; Guelfguat, Mark; Blumfield, Amit; Goldman, Harold
2015-12-01
We would like to share our experience of reducing pediatric radiation exposure. Much of the recent literature regarding successes of reducing radiation exposure has come from dedicated children's hospitals. Nonetheless, over the past two decades, there has been a considerable increase in CT imaging of children in the USA, predominantly in non-pediatric-focused facilities where the majority of children are treated. In our institution, two general hospitals with limited pediatric services, a dedicated initiative intended to reduce children's exposure to CT radiation was started by pediatric radiologists in 2005. The initiative addressed multiple issues including eliminating multiphase studies, decreasing inappropriate scans, educating referring providers, training residents and technologists, replacing CT with ultrasound or MRI, and ensuring availability of pediatric radiologists for consultation. During the study period, the total number of CT scans decreased by 24 %. When accounting for the number of scans per visit to the emergency department (ED), the numbers of abdominal and head CT scans decreased by 37.2 and 35.2 %, respectively. For abdominal scans, the average number of phases per scan decreased from 1.70 to 1.04. Upon surveying the pediatric ED staff, it was revealed that the most influential factors on ordering of scans were daily communication with pediatric radiologists, followed by journal articles and lectures by pediatric radiologists. We concluded that a non-pediatric-focused facility can achieve dramatic reduction in CT radiation exposure to children; however, this is most effectively achieved through a dedicated, multidisciplinary process led by pediatric radiologists.
Varying-energy CT imaging method based on EM-TV
NASA Astrophysics Data System (ADS)
Chen, Ping; Han, Yan
2016-11-01
For complicated structural components with wide x-ray attenuation ranges, conventional fixed-energy computed tomography (CT) imaging cannot obtain all the structural information. This limitation results in a shortage of CT information because the effective thickness of the components along the direction of x-ray penetration exceeds the limit of the dynamic range of the x-ray imaging system. To address this problem, a varying-energy x-ray CT imaging method is proposed. In this new method, the tube voltage is adjusted several times with the fixed lesser interval. Next, the fusion of grey consistency and logarithm demodulation are applied to obtain full and lower noise projection with a high dynamic range (HDR). In addition, for the noise suppression problem of the analytical method, EM-TV (expectation maximization-total Jvariation) iteration reconstruction is used. In the process of iteration, the reconstruction result obtained at one x-ray energy is used as the initial condition of the next iteration. An accompanying experiment demonstrates that this EM-TV reconstruction can also extend the dynamic range of x-ray imaging systems and provide a higher reconstruction quality relative to the fusion reconstruction method.
3D intrathoracic region definition and its application to PET-CT analysis
NASA Astrophysics Data System (ADS)
Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.
2014-03-01
Recently developed integrated PET-CT scanners give co-registered multimodal data sets that offer complementary three-dimensional (3D) digital images of the chest. PET (positron emission tomography) imaging gives highly specific functional information of suspect cancer sites, while CT (X-ray computed tomography) gives associated anatomical detail. Because the 3D CT and PET scans generally span the body from the eyes to the knees, accurate definition of the intrathoracic region is vital for focusing attention to the central-chest region. In this way, diagnostically important regions of interest (ROIs), such as central-chest lymph nodes and cancer nodules, can be more efficiently isolated. We propose a method for automatic segmentation of the intrathoracic region from a given co-registered 3D PET-CT study. Using the 3D CT scan as input, the method begins by finding an initial intrathoracic region boundary for a given 2D CT section. Next, active contour analysis, driven by a cost function depending on local image gradient, gradient-direction, and contour shape features, iteratively estimates the contours spanning the intrathoracic region on neighboring 2D CT sections. This process continues until the complete region is defined. We next present an interactive system that employs the segmentation method for focused 3D PET-CT chest image analysis. A validation study over a series of PET-CT studies reveals that the segmentation method gives a Dice index accuracy of less than 98%. In addition, further results demonstrate the utility of the method for focused 3D PET-CT chest image analysis, ROI definition, and visualization.
Fouquet, Guillemette; Guidez, Stéphanie; Herbaux, Charles; Van de Wyngaert, Zoé; Bonnet, Sarah; Beauvais, David; Demarquette, Hélène; Adib, Salim; Hivert, Bénédicte; Wemeau, Mathieu; Berthon, Céline; Terriou, Louis; Coiteux, Valérie; Macro, Margaret; Decaux, Olivier; Facon, Thierry; Huglo, Damien; Leleu, Xavier
2014-06-15
Solitary plasmacytoma (SP) is a localized proliferation of monoclonal plasma cells in either bone or soft tissue, without evidence of multiple myeloma (MM), and whose prognosis is marked by a high risk of transformation to MM. We studied the impact of FDG-PET/CT (2[18F]fluoro-2-deoxy-D-glucose positron emission tomography-computed tomography) on the risk of transformation of SP to overt MM among other markers in a series of 43 patients diagnosed with SP. Median age was 57.5 years; 48% of patients had an abnormal involved serum-free light chain (sFLC) value, and 64% had an abnormal sFLC ratio at diagnosis. Thirty-three percent had two or more hypermetabolic lesions on initial PET/CT, and 20% had two or more focal lesions on initial MRI. With a median follow-up of 50 months, 14 patients transformed to MM with a median time (TTMM) of 71 months. The risk factors that significantly shortened TTMM at diagnosis were two or more hypermetabolic lesions on PET/CT, abnormal sFLC ratio and involved sFLC, and to a lesser extent at completion of treatment, absence of normalized involved sFLC and PET/CT or MRI. In a multivariate analysis, abnormal initial involved sFLC [OR = 10; 95% confidence interval (CI), 1-87; P = 0.008] and PET/CT (OR = 5; 95% CI, 0-9; P = 0.032) independently shortened TTMM. An abnormal involved sFLC value and the presence of at least two hypermetabolic lesions on PET/CT at diagnosis of SP were the two predictors of early evolution to myeloma in our series. This data analysis will need confirmation in a larger study, and the study of these two risk factors may lead to a different management of patients with SP in the future. . ©2014 American Association for Cancer Research.
In-situ X-ray CT results of damage evolution in L6 ordinary chondrite meteorites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cuadra, Jefferson A.; Hazeli, Kavan; Ramesh, K. T.
2016-06-17
These are slides about in-situ X-ray CT results of damage evolution in L6 ordinary chondrite meteorites. The following topics are covered: mechanical and thermal damage characterization, list of Grosvenor Mountain (GRO) meteorite samples, in-situ x-ray compression test setup, GRO-chipped reference at 0 N - existing cracks, GRO-chipped loaded at 1580 N, in-situ x-ray thermal fatigue test setup, GRO-B14 room temperature reference, GRO-B14 Cycle 47 at 200°C, GRO-B14 Cycle 47 at room temperature, conclusions from qualitative analysis, future work and next steps. Conclusions are the following: Both GRO-Chipped and GRO-B14 had existing voids and cracks within the volume. These sites withmore » existing damage were selected for CT images from mechanically and thermally loaded scans since they are prone to damage initiation. The GRO-Chipped sample was loaded to 1580 N which resulted in a 14% compressive engineering strain, calculated using LVDT. Based on the CT cross sectional images, the GRO-B14 sample at 200°C has a thermal expansion of approximately 96 μm in height (i.e. ~1.6% engineering strain).« less
Automated segmentations of skin, soft-tissue, and skeleton, from torso CT images
NASA Astrophysics Data System (ADS)
Zhou, Xiangrong; Hara, Takeshi; Fujita, Hiroshi; Yokoyama, Ryujiro; Kiryu, Takuji; Hoshi, Hiroaki
2004-05-01
We have been developing a computer-aided diagnosis (CAD) scheme for automatically recognizing human tissue and organ regions from high-resolution torso CT images. We show some initial results for extracting skin, soft-tissue and skeleton regions. 139 patient cases of torso CT images (male 92, female 47; age: 12-88) were used in this study. Each case was imaged with a common protocol (120kV/320mA) and covered the whole torso with isotopic spatial resolution of about 0.63 mm and density resolution of 12 bits. A gray-level thresholding based procedure was applied to separate the human body from background. The density and distance features to body surface were used to determine the skin, and separate soft-tissue from the others. A 3-D region growing based method was used to extract the skeleton. We applied this system to the 139 cases and found that the skin, soft-tissue and skeleton regions were recognized correctly for 93% of the patient cases. The accuracy of segmentation results was acceptable by evaluating the results slice by slice. This scheme will be included in CAD systems for detecting and diagnosing the abnormal lesions in multi-slice torso CT images.
Radiological Findings in a case of Advance staged Mesothelioma
Aziz, Fahad
2009-01-01
Chest X Ray is the initial screening test for the mesothelioma like all other the chest diseases. But computed tomography (CT) is the imaging technique of choice for charactering pleural masses. CT also gives important information regarding invasion of the chest wall and surrounding structures. Certain CT features help differentiate benign from malignant processes. This short article highlights the salient CT appearance of mesothelioma; the most common pleural tumor. PMID:22263002
EPA has initiated a process to revise certain requirements in the WPS. By the end of FY2018, EPA expects to publish a Notice of Proposed Rulemaking to solicit public input on proposed revisions to the WPS requirements for minimum ages, designated represen
Image Reconstruction for Hybrid True-Color Micro-CT
Xu, Qiong; Yu, Hengyong; Bennett, James; He, Peng; Zainon, Rafidah; Doesburg, Robert; Opie, Alex; Walsh, Mike; Shen, Haiou; Butler, Anthony; Butler, Phillip; Mou, Xuanqin; Wang, Ge
2013-01-01
X-ray micro-CT is an important imaging tool for biomedical researchers. Our group has recently proposed a hybrid “true-color” micro-CT system to improve contrast resolution with lower system cost and radiation dose. The system incorporates an energy-resolved photon-counting true-color detector into a conventional micro-CT configuration, and can be used for material decomposition. In this paper, we demonstrate an interior color-CT image reconstruction algorithm developed for this hybrid true-color micro-CT system. A compressive sensing-based statistical interior tomography method is employed to reconstruct each channel in the local spectral imaging chain, where the reconstructed global gray-scale image from the conventional imaging chain served as the initial guess. Principal component analysis was used to map the spectral reconstructions into the color space. The proposed algorithm was evaluated by numerical simulations, physical phantom experiments, and animal studies. The results confirm the merits of the proposed algorithm, and demonstrate the feasibility of the hybrid true-color micro-CT system. Additionally, a “color diffusion” phenomenon was observed whereby high-quality true-color images are produced not only inside the region of interest, but also in neighboring regions. It appears harnessing that this phenomenon could potentially reduce the color detector size for a given ROI, further reducing system cost and radiation dose. PMID:22481806
Development of X-ray computed tomography inspection facility for the H-II solid rocket boosters
NASA Astrophysics Data System (ADS)
Sasaki, M.; Fujita, T.; Fukushima, Y.; Shimizu, M.; Itoh, S.; Satoh, A.; Miyamoto, H.
The National Space Development Agency of Japan (NASDA) initiated the development of an X-ray computed tomography (CT) equipment for the H-II solid rocket boosters (SRBs) in 1987 for the purpose of minimizing inspection time and achieving high cost-effectiveness. The CT facility has been completed in Jan. 1991 in Tanegashima Space Center for the inspection of the SRBs transported from the manufacturer's factory to the launch site. It was first applied to the qualification model SRB from Feb. to Apr. in 1991. Through the CT inspection of the SRB, it has been confirmed that inspection time decreased significantly compared with the X-ray radiography method and that even an unskilled inspector could find various defects. As a result, the establishment of a new reliable inspection method for the SRB has been verified. In this paper, the following are discussed: (1) the defect detectability of the CT equipment using a dummy SRB with various artificial defects, (2) the performance comparison between the CT method and the X-ray radiography method, (3) the reliability of the CT equipment, and (4) the radiation shield design of the nondestructive test building.
Twin robotic x-ray system for 2D radiographic and 3D cone-beam CT imaging
NASA Astrophysics Data System (ADS)
Fieselmann, Andreas; Steinbrener, Jan; Jerebko, Anna K.; Voigt, Johannes M.; Scholz, Rosemarie; Ritschl, Ludwig; Mertelmeier, Thomas
2016-03-01
In this work, we provide an initial characterization of a novel twin robotic X-ray system. This system is equipped with two motor-driven telescopic arms carrying X-ray tube and flat-panel detector, respectively. 2D radiographs and fluoroscopic image sequences can be obtained from different viewing angles. Projection data for 3D cone-beam CT reconstruction can be acquired during simultaneous movement of the arms along dedicated scanning trajectories. We provide an initial evaluation of the 3D image quality based on phantom scans and clinical images. Furthermore, initial evaluation of patient dose is conducted. The results show that the system delivers high image quality for a range of medical applications. In particular, high spatial resolution enables adequate visualization of bone structures. This system allows 3D X-ray scanning of patients in standing and weight-bearing position. It could enable new 2D/3D imaging workflows in musculoskeletal imaging and improve diagnosis of musculoskeletal disorders.
[Clinical analysis of 16 cases frontal, ethmoid sinus cyst with eye symptoms as initial amount].
Zhao, Ying; Sun, Yijun; Yang, Lihui; Jia, Wenxue; Wang, Lijun
2013-11-01
To investigate the diagnosis of frontal, ethmoid sinus cyst with eye symptoms as initial amount,and the curative effect of nasal endoscopic operation. To retrospectively analyze clinical data of sixteen patients with frontal, ethmoid sinus cyst from February 2006 to March 2008. Diagnostic accordance rate of paranasal sinus MRI and CT examination In 16 patients is 100%. Fourteen patients' ocular symptoms disappeared after nasal endoscope operation treatment, two of them improved. None of them recurrened after the fol low-up 3-6 years up to now, all the patients had satisfactory curative effect. Paranasal sinuses and or bital cavity have close relationship , patients with sinus lesions always firstly visit Ophthalmology doctor. The results of MRI and CT examination are of great value for diagnosis. Patients with frontal, ethmoid sinus cyst with eye symptoms as initial amount should be early diagnosed. The treatment of nasal endoscope operation is safe, effective and is worth of firstly chosen.
CT brush and CancerZap!: two video games for computed tomography dose minimization.
Alvare, Graham; Gordon, Richard
2015-05-12
X-ray dose from computed tomography (CT) scanners has become a significant public health concern. All CT scanners spray x-ray photons across a patient, including those using compressive sensing algorithms. New technologies make it possible to aim x-ray beams where they are most needed to form a diagnostic or screening image. We have designed a computer game, CT Brush, that takes advantage of this new flexibility. It uses a standard MART algorithm (Multiplicative Algebraic Reconstruction Technique), but with a user defined dynamically selected subset of the rays. The image appears as the player moves the CT brush over an initially blank scene, with dose accumulating with every "mouse down" move. The goal is to find the "tumor" with as few moves (least dose) as possible. We have successfully implemented CT Brush in Java and made it available publicly, requesting crowdsourced feedback on improving the open source code. With this experience, we also outline a "shoot 'em up game" CancerZap! for photon limited CT. We anticipate that human computing games like these, analyzed by methods similar to those used to understand eye tracking, will lead to new object dependent CT algorithms that will require significantly less dose than object independent nonlinear and compressive sensing algorithms that depend on sprayed photons. Preliminary results suggest substantial dose reduction is achievable.
Tonolini, Massimo; Ierardi, Anna Maria; Bracchi, Elena; Magistrelli, Paolo; Vella, Adriana; Carrafiello, Gianpaolo
2017-10-01
Despite availability of effective therapies, peptic ulcer disease (PUD) remains a major global disease, resulting from a combination of persistent Helicobacter pylori infection and widespread use of nonsteroidal anti-inflammatory drugs. Albeit endoscopy definitely represents the mainstay diagnostic technique, patients presenting to emergency departments with unexplained abdominal pain generally undergo multidetector CT as an initial investigation. Although superficial ulcers generally remain inconspicuous, careful multiplanar CT interpretation may allow to detect deep ulcers, secondary mural and extraluminal signs of peptic gastroduodenitis, thereby allowing timely endoscopic verification and appropriate treatment. This pictorial essay aims to provide radiologists with an increased familiarity with CT diagnosis of non-perforated PUD, with emphasis on differential diagnosis. Following an overview of current disease epidemiology and complications, it explains the appropriate CT acquisition and interpretation techniques, and reviews with several examples the cross-sectional findings of uncomplicated PUD. Afterwards, the CT features of PUD complications such as ulcer haemorrhage, gastric outlet obstruction, biliary and pancreatic fistulisation are presented. • Gastric and duodenal peptic ulcers are increasingly caused by nonsteroidal anti-inflammatory drugs • Multiplanar CT interpretation allows detecting deep ulcers and secondary signs of gastroduodenitis • CT diagnosis of uncomplicated peptic disease relies on direct and indirect signs • Currently the commonest complication, haemorrhage may be treated with transarterial embolisation • Other uncommon complications include gastric outlet obstruction and biliopancreatic fistulisation.
Cost-effectiveness analysis of PET-CT-guided management for locally advanced head and neck cancer.
Smith, A F; Hall, P S; Hulme, C T; Dunn, J A; McConkey, C C; Rahman, J K; McCabe, C; Mehanna, H
2017-11-01
A recent large United Kingdom (UK) clinical trial demonstrated that positron-emission tomography-computed tomography (PET-CT)-guided administration of neck dissection (ND) in patients with advanced head and neck cancer after primary chemo-radiotherapy treatment produces similar survival outcomes to planned ND (standard care) and is cost-effective over a short-term horizon. Further assessment of long-term outcomes is required to inform a robust adoption decision. Here we present results of a lifetime cost-effectiveness analysis of PET-CT-guided management from a UK secondary care perspective. Initial 6-month cost and health outcomes were derived from trial data; subsequent incidence of recurrence and mortality was simulated using a de novo Markov model. Health benefit was measured in quality-adjusted life years (QALYs) and costs reported in 2015 British pounds. Model parameters were derived from trial data and published literature. Sensitivity analyses were conducted to assess the impact of uncertainty and broader National Health Service (NHS) and personal social services (PSS) costs on the results. PET-CT management produced an average per-person lifetime cost saving of £1485 and an additional 0.13 QALYs. At a £20,000 willingness-to-pay per additional QALY threshold, there was a 75% probability that PET-CT was cost-effective, and the results remained cost-effective over the majority of sensitivity analyses. When adopting a broader NHS and PSS perspective, PET-CT management produced an average saving of £700 and had an 81% probability of being cost-effective. This analysis indicates that PET-CT-guided management is cost-effective in the long-term and supports the case for wide-scale adoption. Copyright © 2017 Elsevier Ltd. All rights reserved.
WE-AB-202-07: Ventilation CT: Voxel-Level Comparison with Hyperpolarized Helium-3 & Xenon-129 MRI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tahir, B; Marshall, H; Hughes, P
Purpose: To compare the spatial correlation of ventilation surrogates computed from inspiratory and expiratory breath-hold CT with hyperpolarized Helium-3 & Xenon-129 MRI in a cohort of lung cancer patients. Methods: 5 patients underwent expiration & inspiration breath-hold CT. Xenon-129 & {sup 1}H MRI were also acquired at the same inflation state as inspiratory CT. This was followed immediately by acquisition of Helium-3 & {sup 1}H MRI in the same breath and at the same inflation state as inspiratory CT. Expiration CT was deformably registered to inspiration CT for calculation of ventilation CT from voxel-wise differences in Hounsfield units. Inspiration CTmore » and the Xenon-129’s corresponding anatomical {sup 1}H MRI were registered to Helium-3 MRI via the same-breath anatomical {sup 1}H MRI. This enabled direct comparison of CT ventilation with Helium-3 MRI & Xenon-129 MRI for the median values in corresponding regions of interest, ranging from finer to coarser in-plane dimensions of 10 by 10, 20 by 20, 30 by 30 and 40 by 40, located within the lungs as defined by the same-breath {sup 1}H MRI lung mask. Spearman coefficients were used to assess voxel-level correlation. Results: The median Spearman’s coefficients of ventilation CT with Helium-3 & Xenon-129 MRI for ROIs of 10 by 10, 20 by 20, 30 by 30 and 40 by 40 were 0.52, 0.56, 0.60 and 0.68 and 0.40, 0.42, 0.52 and 0.70, respectively. Conclusion: This work demonstrates a method of acquiring CT & hyperpolarized gas MRI (Helium-3 & Xenon-129 MRI) in similar breath-holds to enable direct spatial comparison of ventilation maps. Initial results show moderate correlation between ventilation CT & hyperpolarized gas MRI, improving for coarser regions which could be attributable to the inherent noise in CT intensity, non-ventilatory effects and registration errors at the voxel-level. Thus, it may be more beneficial to quantify ventilation at a more regional level.« less
Omar, Hesham R; Mangar, Devanand; Khetarpal, Suneel; Shapiro, David H; Kolla, Jaya; Rashad, Rania; Helal, Engy; Camporesi, Enrico M
2011-09-27
Pneumothorax is a common complication following blunt chest wall trauma. In these patients, because of the restrictions regarding immobilization of the cervical spine, Anteroposterior (AP) chest radiograph is usually the most feasible initial study which is not as sensitive as the erect chest X-ray or CT chest for detection of a pneumothorax. We will present 3 case reports which serve for better understanding of the entity of occult pneumothorax. The first case is an example of a true occult pneumothorax where an initial AP chest X-ray revealed no evidence of pneumothorax and a CT chest immediately performed revealed evidence of pneumothorax. The second case represents an example of a missed rather than a truly occult pneumothorax where the initial chest radiograph revealed clues suggesting the presence of pneumothorax which were missed by the reading radiologist. The third case emphasizes the fact that "occult pneumothorax is predictable". The presence of subcutaneous emphesema and pulmonary contusion should call for further imaging with CT chest to rule out pneumothorax. Thoracic CT scan is therefore the "gold standard" for early detection of a pneumothorax in trauma patients. This report aims to sensitize readers to the entity of occult pneumothorax and create awareness among intensivists and ER physicians regarding the proper diagnosis and management.
Pereira, Elena; Camacho-Vanegas, Olga; Anand, Sanya; Sebra, Robert; Catalina Camacho, Sandra; Garnar-Wortzel, Leopold; Nair, Navya; Moshier, Erin; Wooten, Melissa; Uzilov, Andrew; Chen, Rong; Prasad-Hayes, Monica; Zakashansky, Konstantin; Beddoe, Ann Marie; Schadt, Eric; Dottino, Peter; Martignetti, John A
2015-01-01
High-grade serous ovarian and endometrial cancers are the most lethal female reproductive tract malignancies worldwide. In part, failure to treat these two aggressive cancers successfully centers on the fact that while the majority of patients are diagnosed based on current surveillance strategies as having a complete clinical response to their primary therapy, nearly half will develop disease recurrence within 18 months and the majority will die from disease recurrence within 5 years. Moreover, no currently used biomarkers or imaging studies can predict outcome following initial treatment. Circulating tumor DNA (ctDNA) represents a theoretically powerful biomarker for detecting otherwise occult disease. We therefore explored the use of personalized ctDNA markers as both a surveillance and prognostic biomarker in gynecologic cancers and compared this to current FDA-approved surveillance tools. Tumor and serum samples were collected at time of surgery and then throughout treatment course for 44 patients with gynecologic cancers, representing 22 ovarian cancer cases, 17 uterine cancer cases, one peritoneal, three fallopian tube, and one patient with synchronous fallopian tube and uterine cancer. Patient/tumor-specific mutations were identified using whole-exome and targeted gene sequencing and ctDNA levels quantified using droplet digital PCR. CtDNA was detected in 93.8% of patients for whom probes were designed and levels were highly correlated with CA-125 serum and computed tomography (CT) scanning results. In six patients, ctDNA detected the presence of cancer even when CT scanning was negative and, on average, had a predictive lead time of seven months over CT imaging. Most notably, undetectable levels of ctDNA at six months following initial treatment was associated with markedly improved progression free and overall survival. Detection of residual disease in gynecologic, and indeed all cancers, represents a diagnostic dilemma and a potential critical inflection point in precision medicine. This study suggests that the use of personalized ctDNA biomarkers in gynecologic cancers can identify the presence of residual tumor while also more dynamically predicting response to treatment relative to currently used serum and imaging studies. Of particular interest, ctDNA was an independent predictor of survival in patients with ovarian and endometrial cancers. Earlier recognition of disease persistence and/or recurrence and the ability to stratify into better and worse outcome groups through ctDNA surveillance may open the window for improved survival and quality and life in these cancers.
Patel, Mayur B; Humble, Stephen S; Cullinane, Daniel C; Day, Matthew A; Jawa, Randeep S; Devin, Clinton J; Delozier, Margaret S; Smith, Lou M; Smith, Miya A; Capella, Jeannette M; Long, Andrea M; Cheng, Joseph S; Leath, Taylor C; Falck-Ytter, Yngve; Haut, Elliott R; Como, John J
2015-02-01
With the use of the framework advocated by the Grading of Recommendations Assessment, Development and Evaluation (GRADE) Working Group, our aims were to perform a systematic review and to develop evidence-based recommendations that may be used to answer the following PICO [Population, Intervention, Comparator, Outcomes] question:In the obtunded adult blunt trauma patient, should cervical collar removal be performed after a negative high-quality cervical spine (C-spine) computed tomography (CT) result alone or after a negative high-quality C-spine CT result combined with adjunct imaging, to reduce peri-clearance events, such as new neurologic change, unstable C-spine injury, stable C-spine injury, need for post-clearance imaging, false-negative CT imaging result on re-review, pressure ulcers, and time to cervical collar clearance? Our protocol was registered with the PROSPERO international prospective register of systematic reviews on August 23, 2013 (REGISTRATION NUMBER: CRD42013005461). Eligibility criteria consisted of adult blunt trauma patients 16 years or older, who underwent C-spine CT with axial thickness of less than 3 mm and who were obtunded using any definition.Quantitative synthesis via meta-analysis was not possible because of pre-post, partial-cohort, quasi-experimental study design limitations and the consequential incomplete diagnostic accuracy data. Of five articles with a total follow-up of 1,017 included subjects, none reported new neurologic changes (paraplegia or quadriplegia) after cervical collar removal. There is a worst-case 9% (161 of 1,718 subjects in 11 studies) cumulative literature incidence of stable injuries and a 91% negative predictive value of no injury, after coupling a negative high-quality C-spine CT result with 1.5-T magnetic resonance imaging, upright x-rays, flexion-extension CT, and/or clinical follow-up. Similarly, there is a best-case 0% (0 of 1,718 subjects in 11 studies) cumulative literature incidence of unstable injuries after negative initial imaging result with a high-quality C-spine CT. In obtunded adult blunt trauma patients, we conditionally recommend cervical collar removal after a negative high-quality C-spine CT scan result alone. Systematic review, level III.
1236 C/T and 3435 C/T polymorphisms of the ABCB1 gene in Mexican breast cancer patients.
Gutierrez-Rubio, S A; Quintero-Ramos, A; Durán-Cárdenas, A; Franco-Topete, R A; Castro-Cervantes, J M; Oceguera-Villanueva, A; Jiménez-Pérez, L M; Balderas-Peña, L M A; Morgan-Villela, G; Del-Toro-Arreola, A; Daneri-Navarro, A
2015-02-13
MDR1, which is encoded by the ABCB1 gene, is involved in multidrug resistance (hydrophobic), as well as the elimination of xenotoxic agents. The association between ABCB1 gene polymorphisms and breast cancer risk in different populations has been described previously; however, the results have been inconclusive. In this study, we examined the association between polymorphisms 3435 C/T and 1236 C/T in the ABCB1 gene and breast cancer development in Mexican women according to their menopausal status and molecular classification. Molecular subtypes as well as allele and genotype frequencies were analyzed. A total of 248 women with initial breast cancer diagnosis and 180 ethnically matched, healthy, unrelated individuals were enrolled. Polymerase chain reaction-restriction fragment length polymorphism was performed to detect polymorphisms 3435 C/T and 1236 C/T in the ABCB1 gene. Premenopausal T allele carriers of the 3435 C/T polymorphism showed a 2-fold increased risk of breast cancer with respect to the reference and postmenopausal groups, as well as triple-negative expression regarding the luminal A/B molecular subrogated subtypes. In contrast, the CT genotype of the 1236 polymorphism was a protective factor against breast cancer. We conclude that the T allele carrier of the 3435 C/T polymorphism in the ABCB1 gene in combination with an estrogen receptor-negative status may be an important risk factor for breast cancer development in premenopausal women.
The Beck Initiative: Training School-Based Mental Health Staff in Cognitive Therapy
ERIC Educational Resources Information Center
Creed, Torrey A.; Jager-Hyman, Shari; Pontoski, Kristin; Feinberg, Betsy; Rosenberg, Zachary; Evans, Arthur; Hurford, Matthew O.; Beck, Aaron T.
2013-01-01
A growing literature supports cognitive therapy (CT) as an efficacious treatment for youth struggling with emotional or behavioral problems. Recently, work in this area has extended the dissemination of CT to school-based settings. The current study has two aims: 1) to examine the development of therapists' knowledge and skills in CT, an…
Mann, Steve D.; Perez, Kristy L.; McCracken, Emily K. E.; Shah, Jainil P.; Wong, Terence Z.; Tornai, Martin P.
2012-01-01
A pilot study is underway to quantify in vivo the uptake and distribution of Tc-99m Sestamibi in subjects without previous history of breast cancer using a dedicated SPECT-CT breast imaging system. Subjects undergoing diagnostic parathyroid imaging studies were consented and imaged as part of this IRB-approved breast imaging study. For each of the seven subjects, one randomly selected breast was imaged prone-pendant using the dedicated, compact breast SPECT-CT system underneath the shielded patient support. Iteratively reconstructed and attenuation and/or scatter corrected images were coregistered; CT images were segmented into glandular and fatty tissue by three different methods; the average concentration of Sestamibi was determined from the SPECT data using the CT-based segmentation and previously established quantification techniques. Very minor differences between the segmentation methods were observed, and the results indicate an average image-based in vivo Sestamibi concentration of 0.10 ± 0.16 μCi/mL with no preferential uptake by glandular or fatty tissues. PMID:22956950
[Tuberculous otomastoiditis: advantage of MRI in the treatment survey].
Moya, Plana A; Malinvaud, D; Mimoun, M; Huart, J; Bonfils, P
2008-01-01
Mycobacterium tuberculosis is a rare cause of otomastoiditis, accounting for less than a percent of chronic otitis media. The diagnosis is difficult and typically delayed because most physicians are unfamiliar with its presenting features and special laboratory requirements. Such delayed diagnosis leads to delayed treatment onset, and thus, increases complications frequency as irreversible hearing loss, facial palsy or meningo-encephalitis complications. Moreover non specific CT findings do not allow any accurate evaluation of inner ear lesions initially and under treatment. We described the first case of MRI of tuberculous mastoiditis and the evolution over a 2-years follow-up period. A patient with a clinical history of chronic otorrhea, resistant to conventional therapy, was referred to our department. CT and MRI permitted to describe the initial lesions and to appreciate the medical treatment efficiency (in order to perform surgery in case of failure or complications). Under medical treatment, MRI showed abscess volume decrease at three months while CT was still unchanged. Remineralization only was observed on CT at 12 months. The patient's healing was obtained after 15 months of antituberculous medication. MRI has the advantage over CT to demonstrate directly abscess collections that superimposed to areas of bone destructions within the temporal bone. Initially, MRI allows an accurate evaluation of abscess collections and possible meningo-encephalitis complications. Moreover, MRI precises earlier than CT the improvement of lesions and the efficacy of medical treatment, and thus, permitting us to postpone surgery where it is unnecessary.
Smoking cessation results in a clinical lung cancer screening program.
Borondy Kitts, Andrea K; McKee, Andrea B; Regis, Shawn M; Wald, Christoph; Flacke, Sebastian; McKee, Brady J
2016-07-01
Lung cancer screening may provide a "teachable moment" for promoting smoking cessation. This study assessed smoking cessation and relapse rates among individuals undergoing follow-up low-dose chest computed tomography (CT) in a clinical CT lung screening program and assessed the influence of initial screening results on smoking behavior. Self-reported smoking status for individuals enrolled in a clinical CT lung screening program undergoing a follow-up CT lung screening exam between 1st February, 2014 and 31st March, 2015 was retrospectively reviewed and compared to self-reported smoking status using a standardized questionnaire at program entry. Point prevalence smoking cessation and relapse rates were calculated across the entire population and compared with exam results. All individuals undergoing screening fulfilled the National Comprehensive Cancer Network Clinical Practice Guidelines in Oncology: Lung Cancer Screening v1.2012(®) high-risk criteria and had an order for CT lung screening. A total of 1,483 individuals underwent a follow-up CT lung screening exam during the study interval. Smoking status at time of follow-up exam was available for 1,461/1,483 (98.5%). A total of 46% (678/1,461) were active smokers at program entry. The overall point prevalence smoking cessation and relapse rates were 20.8% and 9.3%, respectively. Prior positive screening exam results were not predictive of smoking cessation (OR 1.092; 95% CI, 0.715-1.693) but were predictive of reduced relapse among former smokers who had stopped smoking for 2 years or less (OR 0.330; 95% CI, 0.143-0.710). Duration of program enrollment was predictive of smoking cessation (OR 0.647; 95% CI, 0.477-0.877). Smoking cessation and relapse rates in a clinical CT lung screening program rates are more favorable than those observed in the general population. Duration of participation in the screening program correlated with increased smoking cessation rates. A positive exam result correlated with reduced relapse rates among smokers recently quit smoking.
Compact Torus Acceleration and Injection Experiment
NASA Astrophysics Data System (ADS)
Fukumoto, Naoyuki; Fujiwara, Makoto; Nagata, Masayoshi; Uyama, Tadao; Oda, Yasushi; Azuma, Kingo
1996-11-01
The spheromak-type compact torus (CT) acceleration and injection experiment has been carried out using the Himeji Institute of Technology Compact Torus Injector (HIT-CTI). We explore the possibility of refueling, density control, current drive, and edge electric field control of tokamak plasma by means of CT injection. In last September the new HIT-CTI was built up to achieve higher speed (Vct>200 km/s) and higher density CT plasmoid by improving the capacitor bank system and eliminating the impurity and neutral particles. At initial formation discharge tests the gun for formation and compression successfully produced a CT plasmoid and injected it between electrodes for acceleration. (Initial velocity Vct.ini. 32 km/s, Bct 1 kG, Rct=5.5 cm). The formation capacitor bank will be upgraded to two 36 mF capacitors operating at 20 kV (14.4 kJ). The acceleration capacitor bank will be also upgraded to two 36 mF capacitors operating at 20 kV (14.4 kJ). The HIT-CTI will be optimized to obtain suitable CT parameters after acceleration (Bct>5 kG, Lct 20 cm, Vct>200 km/s). In the respect of CT parameter measurement magnetic probes and a He-Ne laser interferometer will be employed in order to measure the CT magnetic field, velocity, density, and length. CT acceleration experimental data on the HIT-CTI and the plan of CT injection experiment on the JFT-2M tokamak (JAERI) will be presented at the meeting.
Raade, Merja; Hämäläinen, Esa; Sane, Timo
2015-01-01
Background Current guidelines for follow-up of adrenal incidentalomas are extensive and hampered by lack of follow-up studies. We tested the hypothesis that small lipid-rich adrenal incidentalomas, initially characterized by tumor size <40 mm and <10 Hounsfield units (HUs) on unenhanced computed tomography (CT) may not demonstrate excessive growth/hormonal hypersecretion on follow-up. Methods Sixty-nine incidentalomas in 56 patients were restudied with unenhanced CT and screening for hypercortisolism (dexamethasone suppression test [DST], plasma adrenocorticotropic hormone) and pheochromocytoma (24-hour urinary metanephrines and normetanephrines) 5 years later. Primary hyperaldosteronism was excluded at base-line. Results Tumor (n=69) size was similar before and after 5 years follow-up (19±6 mm vs. 20±7 mm). Mean tumor growth was 1±2 mm. Largest increase in tumor size was 8 mm, this tumor was surgically removed and histopathology confirmed cortical adenoma. DST was normal in 54 patients and two patients (3.6%) were still characterized by subclinical hypercortisolism. Initial tumor size was >20 mm for the patient with largest tumor growth and those with subclinical hypercortisolism. All patients had normal 24-hour urinary metanephrines and normetanephrines. Low attenuation (<10 HU) was demonstrated in 97% of 67 masses re-evaluated with unenhanced CT. Conclusion None of the patients developed clinically relevant tumor growth or new subclinical hypercortisolism. Biochemical screening for pheochromocytoma in incidentalomas demonstrating <10 HU on unenhanced CT is not needed. For such incidentalomas <40 mm, it seems sufficient to perform control CT and screen for hypercortisolism after 5 years. PMID:26354488
Okuyucu, Kursat; Ozaydın, Sukru; Alagoz, Engin; Ozgur, Gokhan; Oysul, Fahrettin Guven; Ozmen, Ozlem; Tuncel, Murat; Ozturk, Mustafa; Arslan, Nuri
2016-01-01
Abstract Background Non-Hodgkin’s lymphomas arising from the tissues other than primary lymphatic organs are named primary extranodal lymphoma. Most of the studies evaluated metabolic tumor parameters in different organs and histopathologic variants of this disease generally for treatment response. We aimed to evaluate the prognostic value of metabolic tumor parameters derived from initial FDG-PET/CT in patients with a medley of primary extranodal lymphoma in this study. Patients and methods There were 67 patients with primary extranodal lymphoma for whom FDG-PET/CT was requested for primary staging. Quantitative PET/CT parameters: maximum standardized uptake value (SUVmax), average standardized uptake value (SUVmean), metabolic tumor volume (MTV) and total lesion glycolysis (TLG) were used to estimate disease-free survival and overall survival. Results SUVmean, MTV and TLG were found statistically significant after multivariate analysis. SUVmean remained significant after ROC curve analysis. Sensitivity and specificity were calculated as 88% and 64%, respectively, when the cut-off value of SUVmean was chosen as 5.15. After the investigation of primary presentation sites and histo-pathological variants according to recurrence, there is no difference amongst the variants. Primary site of extranodal lymphomas however, is statistically important (p = 0.014). Testis and central nervous system lymphomas have higher recurrence rate (62.5%, 73%, respectively). Conclusions High SUVmean, MTV and TLG values obtained from primary staging FDG-PET/CT are potential risk factors for both disease-free survival and overall survival in primary extranodal lymphoma. SUVmean is the most significant one amongst them for estimating recurrence/metastasis. PMID:27904443
Cho, S H; Sung, Y M; Kim, M S
2012-01-01
Objective The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. Methods 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. Results 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Conclusion Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images. PMID:22514102
Rapidly Progressive Maxillary Atelectasis.
Elkhatib, Ahmad; McMullen, Kyle; Hachem, Ralph Abi; Carrau, Ricardo L; Mastros, Nicholas
2017-07-01
Report of a patient with rapidly progressive maxillary atelectasis documented by sequential imaging. A 51-year-old man, presented with left periorbital and retro-orbital pain associated with left nasal obstruction. An initial computed tomographic (CT) scan of the paranasal sinuses failed to reveal any significant abnormality. A subsequent CT scan, indicated for recurrence of symptoms 11 months later, showed significant maxillary atelectasis. An uncinectomy, maxillary antrostomy, and anterior ethmoidectomy resulted in a complete resolution of the symptoms. Chronic maxillary atelectasis is most commonly a consequence of chronic rhinosinusitis. All previous reports have indicated a chronic process but lacked documentation of the course of the disease. This report documents a patient of rapidly progressive chronic maxillary atelectasis with CT scans that demonstrate changes in the maxillary sinus (from normal to atelectatic) within 11 months.
Characteristics of Rib Fractures in Child Abuse-The Role of Low-Dose Chest Computed Tomography.
Sanchez, Thomas R; Grasparil, Angelo D; Chaudhari, Ruchir; Coulter, Kevin P; Wootton-Gorges, Sandra L
2018-02-01
Our aim is to describe the radiologic characteristics of rib fractures in clinically diagnosed cases of child abuse and suggest a complementary imaging for radiographically occult injuries in highly suspicious cases of child abuse. Retrospective analysis of initial and follow-up skeletal surveys and computed tomography (CT) scans of 16 patients younger than 12 months were reviewed after obtaining approval from our institutional review board. The number, location, displacement, and age of the rib fractures were recorded. Out of a total 105 rib fractures, 84% (87/105) were detected on the initial skeletal survey. Seventeen percent (18/105) were seen only after follow-up imaging, more than half of which (11/18) were detected on a subsequent CT. Majority of the fractures were posterior (43%) and anterior (30%) in location. An overwhelming majority (96%) of the fractures are nondisplaced. Seventeen percent of rib fractures analyzed in the study were not documented on the initial skeletal survey. Majority of fractures are nondisplaced and located posteriorly or anteriorly, areas that are often difficult to assess especially in the acute stage. The CT scan is more sensitive in evaluating these types of fractures. Low-dose chest CT can be an important imaging modality for suspicious cases of child abuse when initial radiographic findings are inconclusive.
Utilization of head CT during injury visits to United States emergency departments: 2012-2015.
Yun, Brian J; Borczuk, Pierre; Zachrison, Kori S; Goldstein, Joshua N; Berlyand, Yosef; Raja, Ali S
2018-05-18
Studies have shown increasing utilization of head computed tomography (CT) imaging of emergency department (ED) patients presenting with an injury-related visit. Multiple initiatives, including the Choosing Wisely™ campaign and evidence-based clinical decision support based on validated decision rules, have targeted head CT use in patients with injuries. Therefore, we investigated national trends in the use of head CT during injury-related ED visits from 2012 to 2015. This was a secondary analysis of data from the annual United States (U.S.) National Hospital Ambulatory Medical Care Survey from 2012 to 2015. The study population was defined as injury-related ED visits, and we sought to determine the percentage in which a head CT was ordered and, secondarily, to determine both the diagnostic yield of clinically significant intracranial findings and hospital characteristics associated with increased head CT utilization. Between 2012 and 2015, 12.25% (95% confidence interval [CI] 11.48-13.02%) of injury-related visits received at least one head CT. Overall head CT utilization showed an increased trend during the study period (2012: 11.7%, 2015: 13.23%, p = 0.09), but the results were not statistically significant. The diagnostic yield of head CT for a significant intracranial injury over the period of four years was 7.4% (9.68% in 2012 vs. 7.67% in 2015, p = 0.23). Head CT use along with diagnostic yield has remained stable from 2012 to 2015 among patients presenting to the ED for an injury-related visit. Copyright © 2017 Elsevier Inc. All rights reserved.
Harding-Esch, E M; Cousins, E C; Chow, S-L C; Phillips, L T; Hall, C L; Cooper, N; Fuller, S S; Nori, A V; Patel, R; Thomas-William, S; Whitlock, G; Edwards, S J E; Green, M; Clarkson, J; Arlett, B; Dunbar, J K; Lowndes, C M; Sadiq, S T
2018-02-01
Rapid Point-Of-Care Tests for Chlamydia trachomatis (CT) may reduce onward transmission and reproductive sexual health (RSH) sequelae by reducing turnaround times between diagnosis and treatment. The io® single module system (Atlas Genetics Ltd.) runs clinical samples through a nucleic acid amplification test (NAAT)-based CT cartridge, delivering results in 30min. Prospective diagnostic accuracy study of the io® CT-assay in four UK Genito-Urinary Medicine (GUM)/RSH clinics on additional-to-routine self-collected vulvovaginal swabs. Samples were tested "fresh" within 10days of collection, or "frozen" at -80°C for later testing. Participant characteristics were collected to assess risk factors associated with CT infection. CT prevalence was 7.2% (51/709) overall. Sensitivity, specificity, positive and negative predictive values of the io® CT assay were, respectively, 96.1% (95% Confidence Interval (CI): 86.5-99.5), 97.7% (95%CI: 96.3-98.7), 76.6% (95%CI: 64.3-86.2) and 99.7% (95%CI: 98.9-100). The only risk factor associated with CT infection was being a sexual contact of an individual with CT. The io® CT-assay is a 30-min, fully automated, high-performing NAAT currently CE-marked for CT diagnosis in women, making it a highly promising diagnostic to enable specific treatment, initiation of partner notification and appropriately intensive health promotion at the point of care. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Nanni, Cristina; Schiavina, Riccardo; Boschi, Stefano; Ambrosini, Valentina; Pettinato, Cinzia; Brunocilla, Eugenio; Martorana, Giuseppe; Fanti, Stefano
2013-07-01
We assessed the rate of detection rate of recurrent prostate cancer by PET/CT using anti-3-(18)F-FACBC, a new synthetic amino acid, in comparison to that using (11)C-choline as part of an ongoing prospective single-centre study. Included in the study were 15 patients with biochemical relapse after initial radical treatment of prostate cancer. All the patients underwent anti-3-(18)F-FACBC PET/CT and (11)C-choline PET/CT within a 7-day period. The detection rates using the two compounds were determined and the target-to-background ratios (TBR) of each lesion are reported. No adverse reactions to anti-3-(18)F-FACBC PET/CT were noted. On a patient basis, (11)C-choline PET/CT was positive in 3 patients and negative in 12 (detection rate 20%), and anti-3-(18)F-FACBC PET/CT was positive in 6 patients and negative in 9 (detection rate 40%). On a lesion basis, (11)C-choline detected 6 lesions (4 bone, 1 lymph node, 1 local relapse), and anti-3-(18)F-FACBC detected 11 lesions (5 bone, 5 lymph node, 1 local relapse). All (11)C-choline-positive lesions were also identified by anti-3-(18)F-FACBC PET/CT. The TBR of anti-3-(18)F-FACBC was greater than that of (11)C-choline in 8/11 lesions, as were image quality and contrast. Our preliminary results indicate that anti-3-(18)F-FACBC may be superior to (11)C-choline for the identification of disease recurrence in the setting of biochemical failure. Further studies are required to assess efficacy of anti-3-(18)F-FACBC in a larger series of prostate cancer patients.
Jadhav, Swati S; Lila, Anurag R; Kasaliwal, Rajeev; Khare, Shruti; Yerawar, Chaitanya G; Hira, Priya; Phadke, Uday; Shah, Hina; Lele, Vikram R; Malhotra, Gaurav; Bandgar, Tushar; Shah, Nalini S
2016-01-01
Background Localising ectopic adrenocorticotrophic hormone (ACTH) syndrome (EAS) tumour source is challenging. Somatostatin receptor-based PET imaging has shown promising results, but the data is limited to case reports and small case series. We reviewed here the performance of 68Ga-DOTANOC positron emission tomography (PET)/computed tomography (CT) and contrast-enhanced CT (CECT) in our cohort of 12 consecutive EAS patients. Materials and methods Retrospective data analysis of 12 consecutive patients of EAS presenting to a single tertiary care centre in a period between January 2013 and December 2014 was done. CECT and 68Ga-DOTANOC PET/CT were reported (blinded) by an experienced radiologist and a nuclear medicine physician, respectively. The performance of CECT and 68Ga-DOTANOC PET/CT was compared. Results Tumours could be localised in 11 out of 12 patients at initial presentation (overt cases), whereas in one patient, tumour remained occult. Thirteen lesions were identified in 11 patients as EAS source (true positives). CECT localised 12 out of these 13 lesions (sensitivity 92.3%) and identified five false-positive lesions (positive predictive value (PPV) 70.5%). Compared with false-positive lesions, true-positive lesions had greater mean contrast enhancement at 60s (33.2 vs 5.6 Hounsfield units (HU)). 68Ga-DOTANOC PET/CT was able to identify 9 out of 13 lesions (sensitivity 69.2%) and reported no false-positive lesions (PPV 100%). Conclusion CECT remains the first-line investigation in localisation of EAS. The contrast enhancement pattern on CECT can further aid in characterisation of the lesions. 68Ga-DOTANOC PET/CT can be added to CECT, to enhance positive prediction of the suggestive lesions. PMID:27006371
WE-D-9A-02: Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kearney, V; Gu, X; Chen, S
2014-06-15
Purpose: The anatomical changes that occur between the simulation CT and daily cone-beam CT (CBCT) are investigated using an automated landmark-guided deformable image registration (LDIR) algorithm with simultaneous intensity correction. LDIR was designed to be accurate in the presence of tissue intensity mismatch and heavy noise contamination. Method: An auto-landmark generation algorithm was used in conjunction with a local small volume (LSV) gradient matching search engine to map corresponding landmarks between the CBCT and planning CT. The LSVs offsets were used to perform an initial deformation, generate landmarks, and correct local intensity mismatch. The landmarks act as stabilizing controlpoints inmore » the Demons objective function. The accuracy of the LDIR algorithm was evaluated on one synthetic case with ground truth and data of ten head and neck cancer patients. The deformation vector field (DVF) accuracy was accessed using a synthetic case. The Root mean square error of the 3D canny edge (RMSECE), mutual information (MI), and feature similarity index metric (FSIM) were used to access the accuracy of LDIR on the patient data. The quality of the corresponding deformed contours was verified by an attending physician. Results: The resulting 90 percentile DVF error for the synthetic case was within 5.63mm for the original demons algorithm, 2.84mm for intensity correction alone, 2.45mm using controlpoints without intensity correction, and 1.48 mm for the LDIR algorithm. For the five patients the mean RMSECE of the original CT, Demons deformed CT, intensity corrected Demons CT, control-point stabilized deformed CT, and LDIR CT was 0.24, 0.26, 0.20, 0.20, and 0.16 respectively. Conclusion: LDIR is accurate in the presence of multimodal intensity mismatch and CBCT noise contamination. Since LDIR is GPU based it can be implemented with minimal additional strain on clinical resources. This project has been supported by a CPRIT individual investigator award RP11032.« less
Schneiderman, Inna; Kanat-Maymon, Yaniv; Zagoory-Sharon, Orna; Feldman, Ruth
2014-01-01
Early-stage romantic love involves reorganization of neurohormonal systems and behavioral patterns marked by mutual influences between the partners' physiology and behavior. Guided by the biobehavioral synchrony conceptual frame, we tested bidirectional influences between the partners' hormones and conflict behavior at the initiation of romantic love. Participants included 120 new lovers (60 couples) and 40 singles. Plasma levels of five affiliation and stress-related hormones were assessed: oxytocin (OT), prolactin (PRL), testosterone (T), cortisol (CT), and dehydroepiandrosterone sulfate (DHEAS). Couples were observed in conflict interaction coded for empathy and hostility. CT and DHEAS showed direct actor effects: higher CT and DHEAS predicted greater hostility. OT showed direct partner effects: individuals whose partners had higher OT showed greater empathy. T and CT showed combined actor-partner effects. High T predicted greater hostility only when partner also had high T, but lower hostility when partner had low T. Similarly, CT predicted low empathy only in the context of high partner's CT. Mediational analysis indicated that combined high CT in both partners was associated with relationship breakup as mediated by decrease in empathy. Findings demonstrate the mutual influences between hormones and behavior within an attachment bond and underscore the dynamic, co-regulated, and systemic nature of pair-bond formation in humans.
Automatic co-segmentation of lung tumor based on random forest in PET-CT images
NASA Astrophysics Data System (ADS)
Jiang, Xueqing; Xiang, Dehui; Zhang, Bin; Zhu, Weifang; Shi, Fei; Chen, Xinjian
2016-03-01
In this paper, a fully automatic method is proposed to segment the lung tumor in clinical 3D PET-CT images. The proposed method effectively combines PET and CT information to make full use of the high contrast of PET images and superior spatial resolution of CT images. Our approach consists of three main parts: (1) initial segmentation, in which spines are removed in CT images and initial connected regions achieved by thresholding based segmentation in PET images; (2) coarse segmentation, in which monotonic downhill function is applied to rule out structures which have similar standardized uptake values (SUV) to the lung tumor but do not satisfy a monotonic property in PET images; (3) fine segmentation, random forests method is applied to accurately segment the lung tumor by extracting effective features from PET and CT images simultaneously. We validated our algorithm on a dataset which consists of 24 3D PET-CT images from different patients with non-small cell lung cancer (NSCLC). The average TPVF, FPVF and accuracy rate (ACC) were 83.65%, 0.05% and 99.93%, respectively. The correlation analysis shows our segmented lung tumor volumes has strong correlation ( average 0.985) with the ground truth 1 and ground truth 2 labeled by a clinical expert.
Second cancers discovered by (18)FDG PET/CT imaging for choroidal melanoma.
Chin, Kimberly; Finger, Paul T; Kurli, Madhavi; Tena, Lawrence B; Reddy, Shantan
2007-08-01
Positron-emission tomography/computed tomography (PET/CT) is a unique imaging tool that aids in the detection of cancerous lesions. It is currently and widely used for cancer staging (both initial and follow-up). Here we report our findings of second primary cancers incidentally discovered during PET/CT staging of patients with choroidal melanomas. We performed a retrospective case review of 139 patients with uveal melanoma who were subsequently evaluated by whole-body [18-fluorine-labeled] 2-deoxy-2-fluoro-D-glucose ((18)FDG) PET/CT imaging. In this series, 93 were scanned before treatment and 46 during the course of their follow-up systemic examinations. Their mean follow-up was 50.9 months. Six patients (4.3%) had second primary cancers revealed by PET/CT imaging. Three patients (50%) were synchronous (found at initial staging), and the remaining 3 patients (50%) were metachronous (found at follow-up staging). Second primary cancers were found in the lung, breast, uterus, colon, and thyroid. Although whole-body PET/CT scans were ordered as part of the staging process of patients with diagnosed choroidal melanoma, both synchronous and metachronous second primary cancers were found. PET/CT has become an indispensable tool for staging, diagnosis, and treatment planning for choroidal melanoma. The possibility of detecting second primary cancers should also be considered valuable.
Delayed diagnosis of injuries in pediatric trauma: the role of radiographic ordering practices.
Willner, Emily L; Jackson, Hollie A; Nager, Alan L
2012-01-01
We sought to describe the use of radiographic studies in pediatric major trauma patients and determine the extent to which a selective, clinically guided use of imaging contributes to delayed diagnosis of injury (DDI). We conducted a retrospective chart review of 324 consecutive pediatric major trauma patients at our level 1 trauma center. One radiologist reviewed all imaging. Delayed diagnosis of injury was defined as detection after more than 12 hours. Equivalency testing was performed to compare radiology use in patients with and without DDI. Twenty-six (8%) of 324 patients had 36 DDI; 27 (75%) of 36 were orthopedic injuries. Median time to DDI detection was 20.5 hours (interquartile range, 15-60.5). During initial evaluation, DDI patients had similar numbers of plain radiographs (3.5 vs 3, P = .54) but more computed tomographic (CT) scans (4 vs 3, P = .03) compared with patients without DDI. Sixteen percent of all patients received CT thorax; 55%, CT cervical spine; and 56%, CT abdomen. Only 1 clinically important DDI was detected solely on the basis of a later CT scan (0.3%; 95% confidence interval, 0-1.5). No cervical spine, intrathoracic, or intraabdominal DDI was attributable to failure to obtain a CT during initial evaluation. Patients with DDI had higher injury severity scores, intubation rates, and pediatric intensive care unit admission rates than those without DDI. Patients with DDI had similar initial plain x-ray evaluations to patients without DDI, despite DDI patients being more severely injured. Delayed diagnosis of injury was not attributable to inadequate CT use. Most DDIs were orthopedic, highlighting the importance of a tertiary survey and a low threshold for skeletal radiographs. Copyright © 2012 Elsevier Inc. All rights reserved.
Mathieu, Cédric; Ferrer, Ludovic; Carlier, Thomas; Colombié, Mathilde; Rusu, Daniela; Kraeber-Bodéré, Françoise; Campion, Loic; Rousseau, Caroline
2015-01-01
Dynamic image acquisition with (18)F-Choline [fluorocholine (FCH)] PET/CT in prostate cancer is mostly used to overcome the bladder repletion, which could obstruct the loco-regional analysis. The aim of our study was to analyze early dynamic FCH acquisitions to define pelvic lymph node or prostate pathological status. Retrospective analysis was performed on 39 patients for initial staging (n = 18), or after initial treatment (n = 21). Patients underwent 10-min dynamic acquisitions centered on the pelvis, after injection of 3-4 MBq/kg of FCH. Whole-body images were acquired about 1 h after injection using a PET/CT GE Discovery LS (GE-LS) or Siemens Biograph mCT (mCT). Maximum and mean SUV according to time were measured on nodal and prostatic lesions. SUVmean was corrected for partial volume effect (PVEC) with suitable recovery coefficients. The status of each lesion was based on histological results or patient follow-up (>6 months). A Mann-Whitney test and ANOVA were used to compare mean and receiver operating characteristic (ROC) curve analysis. The median PSA was 8.46 ng/mL and the median Gleason score was 3 + 4. Ninety-two lesions (43 lymph nodes and 49 prostate lesions) were analyzed, including 63 malignant lesions. In early dynamic acquisitions, the maximum and mean SUV were significantly higher, respectively, on mCT and GE-LS, in malignant versus benign lesions (p < 0.001, p < 0.001). Mean SUV without PVEC, allowed better discrimination of benign from malignant lesions, in comparison with maximum and mean SUV (with PVEC), for both early and late acquisitions. For patients acquired on mCT, area under the ROC curve showed a trend to better sensitivity and specificity for early acquisitions, compared with late acquisitions (SUVmax AUC 0.92 versus 0.85, respectively). Assessment of lymph nodes and prostate pathological status with early dynamic imaging using PET/CT FCH allowed prostate cancer detection in situations where proof of malignancy is difficult to obtain.
Follow-up brain imaging of 37 children with congenital Zika syndrome: case series study
Aragao, Maria de Fatima Vasco; van der Linden, Vanessa; Parizel, Paul; Jungmann, Patricia; Araújo, Luziany; Abath, Marília; Fernandes, Andrezza; Brainer-Lima, Alessandra; Holanda, Arthur; Mello, Roberto; Sarteschi, Camila; Duarte, Maria do Carmo Menezes Bezerra
2017-01-01
Objective To compare initial brain computed tomography (CT) scans with follow-up CT scans at one year in children with congenital Zika syndrome, focusing on cerebral calcifications. Design Case series study. Setting Barão de Lucena Hospital, Pernambuco state, Brazil. Participants 37 children with probable or confirmed congenital Zika syndrome during the microcephaly outbreak in 2015 who underwent brain CT shortly after birth and at one year follow-up. Main outcome measure Differences in cerebral calcification patterns between initial and follow-up scans. Results 37 children were evaluated. All presented cerebral calcifications on the initial scan, predominantly at cortical-white matter junction. At follow-up the calcifications had diminished in number, size, or density, or a combination in 34 of the children (92%, 95% confidence interval 79% to 97%), were no longer visible in one child, and remained unchanged in two children. No child showed an increase in calcifications. The calcifications at the cortical-white matter junction which were no longer visible at follow-up occurred predominately in the parietal and occipital lobes. These imaging changes were not associated with any clear clinical improvements. Conclusion The detection of cerebral calcifications should not be considered a major criterion for late diagnosis of congenital Zika syndrome, nor should the absence of calcifications be used to exclude the diagnosis. PMID:29030384
Radhakrishnan, Renjith Kalathoorakathu; Mittal, Bhagwant Rai; Gorla, Arun Kumar Reddy; Basher, Rajender Kumar; Sood, Ashwani; Bal, Amanjit; Kalra, Naveen; Khandelwal, Niranjan; Singh, Navneet; Behera, Digambar
2017-12-01
The aim of this study was to assess the feasibility and appraise the diagnostic utility of real time 18 F-FDG PET/CT-guided biopsy under automated robopsy arm (ARA) guidance for the evaluation of thoracic lesions with prior inconclusive biopsy results. PET/CT-guided biopsy of thoracic lesions was performed in patients who had at least one previous inconclusive biopsy. A total of 25 patients (male:female-18 males, 7 females; age: range, 13-75; mean, 53.7) were included in this study. All these patients underwent percutaneous needle biopsies under real-time PET/CT guidance using ARA (ROBIO-EX, Perfint healthcare Pvt Ltd, Chennai, India) needle navigation technique. Histopathology and clinical follow-up results were reviewed for assessing the accuracy of procedures. Adequate representative tissue sample could be retrieved in all the patients. No major procedure-related complications were encountered in any patient. Of the 25 procedures, 21 lesions were positive for malignancy and benign findings were observed in the other 4 lesions on histopathology. None of the patients required further biopsy in arriving at a final diagnosis. Overall diagnostic yield of the procedure was 100%. Real time 18 F-FDG PET/CT guidance for percutaneous biopsies of lung and mediastinal lesions is a feasible technique with potential utility in patients with previous inconclusive biopsy results. Advances in knowledge: 18 F-FDG PET/CT guidance reduces the sampling errors by specifically targeting areas of viability and avoiding necrosis/atelectasis. A navigational tool like ARA is thought to help in accurately targeting these areas.
Geisler, W M; Black, C M; Bandea, C I; Morrison, S G
2008-12-01
To investigate the relationship of Chlamydia trachomatis (CT) outer membrane protein A (OmpA) type to the clearance of CT infection before treatment. CT OmpA genotyping, with amplification and sequencing of ompA, was utilised to study the natural history of CT infection (spontaneous resolution vs persistence) in 102 individuals with chlamydia-positive screening tests returning for treatment. CT OmpA distribution was associated with spontaneous resolution of CT, most notably with CT OmpA genotype J/Ja detected more often from the initial screening CT test than other genotypes in those who then had spontaneous resolution of CT noted at the time of treatment. Five individuals with presumed persisting CT infection had discordant CT OmpA genotypes at the screening and treatment visits, suggesting possible new interval CT infection. Clearance of chlamydia by the host before treatment may be influenced by the CT OmpA genotype infecting the host. CT OmpA genotyping may be a valuable tool in understanding the natural history of chlamydial infections.
Citalopram and escitalopram plasma drug and metabolite concentrations: genome-wide associations.
Ji, Yuan; Schaid, Daniel J; Desta, Zeruesenay; Kubo, Michiaki; Batzler, Anthony J; Snyder, Karen; Mushiroda, Taisei; Kamatani, Naoyuki; Ogburn, Evan; Hall-Flavin, Daniel; Flockhart, David; Nakamura, Yusuke; Mrazek, David A; Weinshilboum, Richard M
2014-08-01
Citalopram (CT) and escitalopram (S-CT) are among the most widely prescribed selective serotonin reuptake inhibitors used to treat major depressive disorder (MDD). We applied a genome-wide association study to identify genetic factors that contribute to variation in plasma concentrations of CT or S-CT and their metabolites in MDD patients treated with CT or S-CT. Our genome-wide association study was performed using samples from 435 MDD patients. Linear mixed models were used to account for within-subject correlations of longitudinal measures of plasma drug/metabolite concentrations (4 and 8 weeks after the initiation of drug therapy), and single-nucleotide polymorphisms (SNPs) were modelled as additive allelic effects. Genome-wide significant associations were observed for S-CT concentration with SNPs in or near the CYP2C19 gene on chromosome 10 (rs1074145, P = 4.1 × 10(-9) ) and with S-didesmethylcitalopram concentration for SNPs near the CYP2D6 locus on chromosome 22 (rs1065852, P = 2.0 × 10(-16) ), supporting the important role of these cytochrome P450 (CYP) enzymes in biotransformation of citalopram. After adjustment for the effect of CYP2C19 functional alleles, the analyses also identified novel loci that will require future replication and functional validation. In vitro and in vivo studies have suggested that the biotransformation of CT to monodesmethylcitalopram and didesmethylcitalopram is mediated by CYP isozymes. The results of our genome-wide association study performed in MDD patients treated with CT or S-CT have confirmed those observations but also identified novel genomic loci that might play a role in variation in plasma levels of CT or its metabolites during the treatment of MDD patients with these selective serotonin reuptake inhibitors. © 2014 The British Pharmacological Society.
Calais, Jeremie; Fendler, Wolfgang P; Herrmann, Ken; Eiber, Matthias; Ceci, Francesco
2018-05-01
This was a head-to-head comparison between 68 Ga-labeled prostate-specific membrane antigen (PSMA)-11 and 18 F-fluciclovine PET/CT in a series of 10 patients with prostate cancer (PCa) recurrence. Methods: In total, 288 patients with PCa recurrence were enrolled in a prospective study of 68 Ga-PSMA-11 PET/CT imaging for recurrent disease localization (ClinicalTrials.gov identifier NCT02940262). We retrospectively identified 10 patients who underwent clinically indicated 18 F-fluciclovine PET/CT prior to enrollment. Results: The median time between the 2 scans was 2.2 mo (range, 0.2-4.2 mo). The median prostate-specific antigen (PSA) value was 1.0 ng/mL (mean, 4.7 ng/mL; range, 0.13-18.1 ng/mL) and 1.1 ng/mL (mean, 6.2 ng/mL; range, 0.24-31.3 ng/mL) at the time of 18 F-fluciclovine and 68 Ga-PSMA-11 PET/CT, respectively. Five of 10 patients (50%) were negative with 18 F-fluciclovine but positive with 68 Ga-PSMA-11 PET/CT. Two of 10 patients (20%) were positive with both 18 F-fluciclovine and 68 Ga-PSMA-11 PET/CT, but 68 Ga-PSMA-11 PET/CT showed additional lymph nodes metastasis. Three of 10 patients (30%) were negative with both 18 F-fluciclovine and 68 Ga-PSMA-11 PET/CT. Conclusion: This case series suggests improved detection rates for 68 Ga-PSMA-11 PET/CT when compared with 18 F-fluciclovine PET/CT in patients with recurrent PCa. Prospective trials designed to directly compare the two should be initiated. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.
Blind CT image quality assessment via deep learning strategy: initial study
NASA Astrophysics Data System (ADS)
Li, Sui; He, Ji; Wang, Yongbo; Liao, Yuting; Zeng, Dong; Bian, Zhaoying; Ma, Jianhua
2018-03-01
Computed Tomography (CT) is one of the most important medical imaging modality. CT images can be used to assist in the detection and diagnosis of lesions and to facilitate follow-up treatment. However, CT images are vulnerable to noise. Actually, there are two major source intrinsically causing the CT data noise, i.e., the X-ray photo statistics and the electronic noise background. Therefore, it is necessary to doing image quality assessment (IQA) in CT imaging before diagnosis and treatment. Most of existing CT images IQA methods are based on human observer study. However, these methods are impractical in clinical for their complex and time-consuming. In this paper, we presented a blind CT image quality assessment via deep learning strategy. A database of 1500 CT images is constructed, containing 300 high-quality images and 1200 corresponding noisy images. Specifically, the high-quality images were used to simulate the corresponding noisy images at four different doses. Then, the images are scored by the experienced radiologists by the following attributes: image noise, artifacts, edge and structure, overall image quality, and tumor size and boundary estimation with five-point scale. We trained a network for learning the non-liner map from CT images to subjective evaluation scores. Then, we load the pre-trained model to yield predicted score from the test image. To demonstrate the performance of the deep learning network in IQA, correlation coefficients: Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are utilized. And the experimental result demonstrate that the presented deep learning based IQA strategy can be used in the CT image quality assessment.
1998-02-01
The Women's Health Initiative (WHI) is a large and complex clinical investigation of strategies for the prevention and control of some of the most common causes of morbidity and mortality among postmenopausal women, including cancer, cardiovascular disease, and osteoporotic fractures. The WHI was initiated in 1992, with a planned completion date of 2007. Postmenopausal women ranging in age from 50 to 79 are enrolled at one of 40 WHI clinical centers nationwide into either a clinical trial (CT) that will include about 64,500 women or an observational study (OS) that will include about 100,000 women. The CT is designed to allow randomized controlled evaluation of three distinct interventions: a low-fat eating pattern, hypothesized to prevent breast cancer and colorectal cancer and, secondarily, coronary heart disease; hormone replacement therapy, hypothesized to reduce the risk of coronary heart disease and other cardiovascular diseases and, secondarily, to reduce the risk of hip and other fractures, with increased breast cancer risk as a possible adverse outcome; and calcium and vitamin D supplementation, hypothesized to prevent hip fractures and, secondarily, other fractures and colorectal cancer. Overall benefit-versus-risk assessment is a central focus in each of the three CT components. Women are screened for participation in one or both of the components--dietary modification (DM) or hormone replacement therapy (HRT)--of the CT, which will randomize 48,000 and 27,500 women, respectively. Women who prove to be ineligible for, or who are unwilling to enroll in, these CT components are invited to enroll in the OS. At their 1-year anniversary of randomization, CT women are invited to be further randomized into the calcium and vitamin D (CaD) trial component, which is projected to include 45,000 women. The average follow-up for women in either CT or OS is approximately 9 years. Concerted efforts are made to enroll women of racial and ethnic minority groups, with a target of 20% of overall enrollment in both the CT and OS. This article gives a brief description of the rationale for the interventions being studied in each of the CT components and for the inclusion of the OS component. Some detail is provided on specific study design choices, including eligibility criteria, recruitment strategy, and sample size, with attention to the partial factorial design of the CT. Some aspects of the CT monitoring approach are also outlined. The scientific and logistic complexity of the WHI implies particular leadership and management challenges. The WHI organization and committee structure employed to respond to these challenges is also briefly described.
Crosbie, Robin A; Nairn, Jonathan; Kubba, Haytham
2016-08-01
Paediatric periorbital cellulitis is a common condition. Accurate assessment can be challenging and appropriate use of CT imaging is essential. We audited admissions to our unit over a four year period, with reference to CT scanning and adherence to our protocol. Retrospective audit of paediatric patients admitted with periorbital cellulitis, 2012-2015. Total of 243 patients included, mean age 4.7 years with slight male predominance, the median length of admission was 2 days. 48/243 (20%) underwent CT during admission, 25 (52%) of these underwent surgical drainage. As per protocol, CT brain performed with all orbital scans; no positive intracranial findings on any initial scan. Three children developed intracranial complications subsequently; all treated with antibiotics. Our re-admission rate within 30 days was 2.5%. Our audit demonstrates benefit of standardising practice and the low CT rate, with high percentage taken to theatre and no missed abscesses, supports the protocol. There may be an argument to avoid CT brain routinely in all initial imaging sequences in those children without neurological signs or symptoms. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Houbois, Christian; Haneder, Stefan; Merkt, Martin; Morelli, John N; Schmidt, Matthias; Hellmich, Martin; Mueller, Roman-Ulrich; Wahba, Roger; Maintz, David; Puesken, Michael
2018-06-01
The current gold standard for determination of split renal function (SRF) is Tc-99m-mercapto-acetyltriglycin (MAG3) scintigraphy. Initial studies comparing MAG3-scintigraphy and CT-based renal cortex volumetry (RCV) for calculation of SRF have shown similar results in highly selected patient collectives with normal renal function (i.e. living kidney donors). This study aims to compare MAG3-scintigraphy and CT-RCV within a large unselected patient collective including patients with impaired renal function. For this assessment, 279 datasets (131 men, 148 women; mean age: 54.2 ± 12.9 years, range: 24-84 years) of patients who underwent MAG3-scintigraphy and contrast-enhanced abdominal CT within two weeks were retrospectively analyzed. Two independent readers assessed the CT-RCV in all CT datasets using a semi-automated volumetry tool. The MAG3-scintigraphy and CT-RCV methods were compared, stratified for the eGFR. Statistical analysis included descriptive statistics as well as inter- observer agreement. The absolute mean difference between the percentage contribution of the left and the right kidneys in total MAG3-clearance was 8.6%. Independent of eGFR, an overall sufficient agreement between both methods was established in all patients. A relatively small, tolerable systemic error resulted in an underestimation (max. 2%) of the left renal contribution to overall RCV. The results demonstrate that CT-RCV is a potential clinical replacement for MAG3-scintigraphy for calculation of SRF: CT-RCV demonstrates clinically tolerable differences with MAG3-scintigraphy, independent of patient eGFR. The relative complexity of the RCV method utilized is a potential limitation and may have contributed to the acceptable but only fair to moderate level of intra-reader reliability. Copyright © 2018 Elsevier B.V. All rights reserved.
Harding-Esch, Emma M.; Sillah, Ansumana; Edwards, Tansy; Burr, Sarah E.; Hart, John D.; Joof, Hassan; Laye, Mass; Makalo, Pateh; Manjang, Ahmed; Molina, Sandra; Sarr-Sissoho, Isatou; Quinn, Thomas C.; Lietman, Tom; Holland, Martin J.; Mabey, David; West, Sheila K.; Bailey, Robin
2013-01-01
Background The World Health Organization has recommended three rounds of mass drug administration (MDA) with antibiotics in districts where the prevalence of follicular trachoma (TF) is ≥10% in children aged 1–9 years, with treatment coverage of at least 80%. For districts at 5–10% TF prevalence it was recommended that TF be assessed in 1–9 year olds in each community within the district, with three rounds of MDA provided to any community where TF≥10%. Worldwide, over 40 million people live in districts whose TF prevalence is estimated to be between 5 and 10%. The best way to treat these districts, and the optimum role of testing for infection in deciding whether to initiate or discontinue MDA, are unknown. Methods In a community randomized trial with a factorial design, we randomly assigned 48 communities in four Gambian districts, in which the prevalence of trachoma was known or suspected to be above 10%, to receive annual mass treatment with expected coverage of 80–89% (“Standard”), or to receive an additional visit in an attempt to achieve coverage of 90% or more (“Enhanced”). The same 48 communities were randomised to receive mass treatment annually for three years (“3×”), or to have treatment discontinued if Chlamydia trachomatis (Ct) infection was not detected in a sample of children in the community after mass treatment (stopping rule(“SR”)). Primary outcomes were the prevalence of TF and of Ct infection in 0–5 year olds at 36 months. Results The baseline prevalence of TF and of Ct infection in the target communities was 6.5% and 0.8% respectively. At 36 months the prevalence of TF was 2.8%, and that of Ct infection was 0.5%. No differences were found between the arms in TF or Ct infection prevalence either at baseline (Standard-3×: TF 5.6%, Ct 0.7%; Standard-SR: TF 6.1%, Ct 0.2%; Enhanced-3×: TF 7.4%, Ct 0.9%; and Enhanced-SR: TF 6.2%, Ct 1.2%); or at 36 months (Standard-3×: TF 2.3%, Ct 1.0%; Standard-SR TF 2.5%, Ct 0.2%; Enhanced-3× TF 3.0%, Ct 0.2%; and Enhanced-SR TF 3.2%, Ct 0.7% ). The implementation of the stopping rule led to treatment stopping after one round of MDA in all communities in both SR arms. Mean treatment coverage of children aged 0–9 in communities randomised to standard treatment was 87.7% at baseline and 84.8% and 88.8% at one and two years, respectively. Mean coverage of children in communities randomized to enhanced treatment was 90.0% at baseline and 94.2% and 93.8% at one and two years, respectively. There was no evidence of any difference in TF or Ct prevalence at 36 months resulting from enhanced coverage or from one round of MDA compared to three. Conclusions The Gambia is close to the elimination target for active trachoma. In districts prioritised for three MDA rounds, one round of MDA reduced active trachoma to low levels and Ct infection was not detectable in any community. There was no additional benefit to giving two further rounds of MDA. Programmes could save scarce resources by determining when to initiate or to discontinue MDA based on testing for Ct infection, and one round of MDA may be all that is necessary in some settings to reduce TF below the elimination threshold. PMID:23785525
Gupta, Manoj; Choudhury, Partha Sarathi; Rawal, Sudhir; Goel, Harish Chandra; Singh, Amitabh; Talwar, Vineet; Sahoo, Saroj Kumar
2017-01-01
Current imaging modalities for prostate cancer (PC) had limitations for risk stratification and staging. Magnetic resonance imaging (MRI) frequently underestimated lymphatic metastasis while bone scintigraphy often had diagnostic dilemmas. Prostatic specific membrane antigen (PSMA) positron emission tomography-computed tomography (PET/CT) has been remarkable in diagnosing PC recurrence and staging. We hypothesized it can become one-stop-shop for initial risk stratification and staging. Ninety seven PSMA PET-CT studies were re analysed for tumor node metastases (TNM) staging and risk stratification of lymphatic and distant metastases proportion. The histopathology of 23/97 patients was available as gold standard. Chi-square test was used for proportion comparison. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), over-estimation, under-estimation and correct-estimation of T and N stages were calculated. Cohen's kappa coefficient (k) was derived for inter-rater agreement. Lymphic or distant metastases detection on PSMA PET/CT increased significantly with increase in risk category. PSMA PET/CT sensitivity, specificity, PPV and NPV for extra prostatic extension (EPE), seminal vesicle invasion (SVI) and lymphatic metastases were 63.16%, 100%, 100%, 36.36% & 55%, 100%, 100%, 25% and 65.62%, 99.31%, 87.50%, 97.53%, respectively. Cohen's kappa coefficient showed substantial agreement between PSMA PET/CT and histopathological lymphic metastases (κ 0.734) however, it was just in fair agreement (κ 0.277) with T stage. PSMA PET/CT over-estimated, under-estimated and correct-estimated T and N stages in 8.71%, 39.13%, 52.17% and 8.71%, 4.35%, 86.96% cases, respectively. We found that PSMA PET/CT has potential for initial risk stratifications with reasonable correct estimation for N stage. However, it can underestimate T stage. Hence, we suggest that PSMA PET/CT should be used for staging and initial risk stratification of PC as one-stop-shop with regional MRI in surgically resectable cases.
Design and development of C-arm based cone-beam CT for image-guided interventions: initial results
NASA Astrophysics Data System (ADS)
Chen, Guang-Hong; Zambelli, Joseph; Nett, Brian E.; Supanich, Mark; Riddell, Cyril; Belanger, Barry; Mistretta, Charles A.
2006-03-01
X-ray cone-beam computed tomography (CBCT) is of importance in image-guided intervention (IGI) and image-guided radiation therapy (IGRT). In this paper, we present a cone-beam CT data acquisition system using a GE INNOVA 4100 (GE Healthcare Technologies, Waukesha, Wisconsin) clinical system. This new cone-beam data acquisition mode was developed for research purposes without interfering with any clinical function of the system. It provides us a basic imaging pipeline for more advanced cone-beam data acquisition methods. It also provides us a platform to study and overcome the limiting factors such as cone-beam artifacts and limiting low contrast resolution in current C-arm based cone-beam CT systems. A geometrical calibration method was developed to experimentally determine parameters of the scanning geometry to correct the image reconstruction for geometric non-idealities. Extensive phantom studies and some small animal studies have been conducted to evaluate the performance of our cone-beam CT data acquisition system.
Imudia, Anthony N.; Detti, Laura; Puscheck, Elizabeth E.; Yelian, Frank D.
2008-01-01
Purpose To determine the prevalence of positive test for Ureaplasma urealyticum (UU), Mycoplasma hominis (MH), Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG) infections, and their corresponding Rubella status when undergoing workup for infertility. Methods Retrospective chart review to determine infection status for UU, MH, CT, and NG as determined by cervical swab, as well as the serum Rubella antibody titer. Results A total of 46 patients of the patients reviewed were positive for UU (20.1%), three patients were positive for MH (1.3%), five patients were positive for CT (2.2%) and one patient was positive for NG (0.4%). Rubella immunity was confirmed in 90.3% of patients. Conclusion Approximately one quarter of women presenting to an infertility clinic seeking to conceive were found to have a positive test for UU, MH, CT or NG infection. Additionally, almost 10% of the patients were Rubella non-immune at the time of presentation for infertility evaluation. PMID:18202910
Linguraru, Marius George; Pura, John A; Chowdhury, Ananda S; Summers, Ronald M
2010-01-01
The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis (CAD) applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D erosion using population historic information of contrast-enhanced liver, spleen, and kidneys was applied to multi-phase data to initialize the 4D graph and adapt to patient specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance and enhancement, and shape and location on organ segmentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wahi-Anwar, M; Young, S; Lo, P
Purpose: A method to discriminate different types of renal cell carcinoma (RCC) was developed using attenuation values observed in multiphasic contrast-enhanced CT. This work evaluates the sensitivity of this RCC discrimination task at different CT radiation dose levels. Methods: We selected 5 cases of kidney lesion patients who had undergone four-phase CT scans covering the abdomen to the lilac crest. Through an IRB-approved study, the scans were conducted on 64-slice CT scanners (Definition AS/Definition Flash, Siemens Healthcare) using automatic tube-current modulation (TCM). The protocol included an initial baseline unenhanced scan, followed by three post-contrast injection phases. CTDIvol (32 cm phantom)more » measured between 9 to 35 mGy for any given phase. As a preliminary study, we limited the scope to the cortico-medullary phase—shown previously to be the most discriminative phase. A previously validated method was used to simulate a reduced dose acquisition via adding noise to raw CT sinogram data, emulating corresponding images at simulated doses of 50%, 25%, and 10%. To discriminate the lesion subtype, ROIs were placed in the most enhancing region of the lesion. The mean HU value of an ROI was extracted and used to discriminate to the worst-case RCC subtype, ranked in the order of clear cell, papillary, chromophobe and the benign oncocytoma. Results: Two patients exhibited a change of worst case RCC subtype between original and simulated scans, at 25% and 10% doses. In one case, the worst-case RCC subtype changed from oncocytoma to chromophobe at 10% and 25% doses, while the other case changed from oncocytoma to clear cell at 10% dose. Conclusion: Based on preliminary results from an initial cohort of 5 patients, worst-case RCC subtypes remained constant at all simulated dose levels except for 2 patients. Further study conducted on more patients will be needed to confirm our findings. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH Grant Support from: U01 CA181156.« less
[Optimization of radiotherapy planning for non-small cell lung cancer (NSCLC) using 18FDG-PET].
Schmidt, S; Nestle, U; Walter, K; Licht, N; Ukena, D; Schnabel, K; Kirsch, C M
2002-10-01
In recent years, FDG-PET examinations have become more important for problems in oncology, especially in staging of bronchogenic carcinoma. In the retrospective study presented here, the influence of PET on the planning of radiotherapy for patients with non-small-cell lung cancer (NSCLC) was investigated. The study involved 39 patients with NSCLC who had been examined by PET for staging. They received radiotherapy on the basis of the anterior/posterior portals including the primary tumour and the mediastinum planned according to CT- and bronchoscopic findings. The results of the PET examination were not considered in initial radiotherapy planning. The portals were retrospectively redefined on the basis of FDG uptake considering the size and localization of the primary tumour; and FDG activities outside the mediastinal part of the portals. In 15 out of 39 patients, the CT/PET-planned portals differed from the CT-planned ones. In most causes (n = 12) the CT/PET field was smaller than the CT field. The median geometric field size of the portals was 179 cm2, after redefinition using PET 166 cm2. In 20 patients with disturbed ventilation caused by the tumour (atelectasis, dystelectosis), a correction of the portal was suggested significantly more frequently than in the other patients (p = 0.03). Our results demonstrate the synergism of topographical (CT) and metabolic (FDG-PET) information, which could be helpful in planning radiotherapy of bronchial carcinoma, especially for patients with disturbed ventilation.
Neuert, Mark A C; Dunning, Cynthia E
2013-09-01
Strain energy-based adaptive material models are used to predict bone resorption resulting from stress shielding induced by prosthetic joint implants. Generally, such models are governed by two key parameters: a homeostatic strain-energy state (K) and a threshold deviation from this state required to initiate bone reformation (s). A refinement procedure has been performed to estimate these parameters in the femur and glenoid; this study investigates the specific influences of these parameters on resulting density distributions in the distal ulna. A finite element model of a human ulna was created using micro-computed tomography (µCT) data, initialized to a homogeneous density distribution, and subjected to approximate in vivo loading. Values for K and s were tested, and the resulting steady-state density distribution compared with values derived from µCT images. The sensitivity of these parameters to initial conditions was examined by altering the initial homogeneous density value. The refined model parameters selected were then applied to six additional human ulnae to determine their performance across individuals. Model accuracy using the refined parameters was found to be comparable with that found in previous studies of the glenoid and femur, and gross bone structures, such as the cortical shell and medullary canal, were reproduced. The model was found to be insensitive to initial conditions; however, a fair degree of variation was observed between the six specimens. This work represents an important contribution to the study of changes in load transfer in the distal ulna following the implementation of commercial orthopedic implants.
Cimitan, Marino; Evangelista, Laura; Hodolič, Marina; Mariani, Giuliano; Baseric, Tanja; Bodanza, Valentina; Saladini, Giorgio; Volterrani, Duccio; Cervino, Anna Rita; Gregianin, Michele; Puccini, Giulia; Guidoccio, Federica; Fettich, Jure; Borsatti, Eugenio
2015-02-01
The objective of this study was to explore the ability of the initial Gleason score (GS) to predict the rate of detection of recurrent prostate cancer (PCa) with (18)F-choline PET/CT in a large cohort of patients. Data from 1,000 patients who had undergone (18)F-choline PET/CT because of biochemical evidence of relapse of PCa between 2004 and 2013 were retrieved from databases at 4 centers. Continuous data were compared by the Student t test or ANOVA, and categoric variables were compared by the χ(2) test. Univariable and multivariable analyses were performed by logistic regression. The GS at diagnosis was less than or equal to 6 in 257 patients, 7 in 347 patients, and greater than 7 in 396 patients. The results of 645 PET/CT scans were positive for PCa recurrence. Eighty-one percent of the positive PET/CT results were found in patients with a PSA level of greater than or equal to 2 ng/mL, 43% were found in patients with a PSA level of 1-2 ng/mL, and 31% were found in patients with a PSA level of less than or equal to 1 ng/mL; 78.8% of patients with positive PET/CT results had a GS of greater than 7. The results of (18)F-choline PET/CT scans were negative in 300 patients; 44% had a GS of less than or equal to 6, 35% had a GS of 7, and 17% had a GS of greater than 7. PET/CT results were rated as doubtful in only 5.5% of patients (median PSA, 1.8 ng/mL). When the GS was greater than 7, the rates of detection of (18)F-choline PET/CT were 51%, 65%, and 91% for a PSA level of less than 1 ng/mL, 1-2 ng/mL, and greater than 2 ng/mL, respectively. In univariable and multivariable analyses, both a GS of 7 and a GS of greater than 7 were independent predictors for positive (18)F-choline PET/CT results (odds ratios, 0.226 and 0.330, respectively; P values for both, <0.001). A high GS at diagnosis is a strong predictive factor for positive (18)F-choline PET/CT scan results for recurrent PCa, even when the PSA level is low (i.e., ≤1 ng/mL). © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Lai, Andrea Z; Schrock, Alexa B; Erlich, Rachel L; Ross, Jeffrey S; Miller, Vincent A; Yakirevich, Evgeny; Ali, Siraj M; Braiteh, Fadi
2017-07-01
ALK rearrangements have been observed in 0.05%-2.5% of patients with colorectal cancers (CRCs) and are predicted to be oncogenic drivers largely mutually exclusive of KRAS, NRAS, or BRAF alterations. Here we present the case of a patient with metastatic CRC who was treatment naïve at the time of molecular testing. Initial ALK immunohistochemistry (IHC) staining was negative, but parallel genomic profiling of both circulating tumor DNA (ctDNA) and tissue using similar hybrid capture-based assays each identified an identical STRN-ALK fusion. Subsequent ALK IHC staining of the same specimens was positive, suggesting that the initial result was a false negative. This report is the first instance of an ALK fusion in CRC detected using a ctDNA assay. Current guidelines for colorectal cancer (CRC) only recommend genomic assessment of KRAS, NRAS, BRAF, and microsatellite instability (MSI) status. ALK rearrangements are rare in CRC, but patients with activating ALK fusions have responded to targeted therapies ALK rearrangements can be detected by genomic profiling of ctDNA from blood or tissue, and this methodology may be informative in cases where immunohistochemistry (IHC) or other standard testing is negative. © AlphaMed Press 2017.
Spontaneous rapid reduction of a large acute subdural hematoma.
Lee, Chul-Hee; Kang, Dong Ho; Hwang, Soo Hyun; Park, In Sung; Jung, Jin-Myung; Han, Jong Woo
2009-12-01
The majority of acute post-traumatic subdural hematomas (ASDH) require urgent surgical evacuation. Spontaneous resolution of ASDH has been reported in some cases. We report here on a case of a patient with a large amount of ASDH that was rapidly reduced. A 61-yr-old man was found unconscious following a high speed motor vehicle accident. On initial examination, his Glasgow Coma Score scale was 4/15. His pupils were fully dilated and non-reactive to bright light. Brain computed tomography (CT) showed a massive right-sided ASDH. The decision was made to treat him conservatively because of his poor clinical condition. Another brain CT approximately 14 hr after the initial scan demonstrated a remarkable reduction of the previous ASDH and there was the new appearance of high density in the subdural space adjacent to the falx and the tentorium. Thirty days after his admission, brain CT revealed chronic SDH and the patient underwent surgery. The patient is currently able to obey simple commands. In conclusion, spontaneous rapid resolution/reduction of ASDH may occur in some patients. The mechanisms are most likely the result of dilution by cerebrospinal fluid and the redistribution of hematoma especially in patients with brain atrophy.
Spontaneous Rapid Reduction of a Large Acute Subdural Hematoma
Kang, Dong Ho; Hwang, Soo Hyun; Park, In Sung; Jung, Jin-Myung; Han, Jong Woo
2009-01-01
The majority of acute post-traumatic subdural hematomas (ASDH) require urgent surgical evacuation. Spontaneous resolution of ASDH has been reported in some cases. We report here on a case of a patient with a large amount of ASDH that was rapidly reduced. A 61-yr-old man was found unconscious following a high speed motor vehicle accident. On initial examination, his Glasgow Coma Score scale was 4/15. His pupils were fully dilated and non-reactive to bright light. Brain computed tomography (CT) showed a massive right-sided ASDH. The decision was made to treat him conservatively because of his poor clinical condition. Another brain CT approximately 14 hr after the initial scan demonstrated a remarkable reduction of the previous ASDH and there was the new appearance of high density in the subdural space adjacent to the falx and the tentorium. Thirty days after his admission, brain CT revealed chronic SDH and the patient underwent surgery. The patient is currently able to obey simple commands. In conclusion, spontaneous rapid resolution/reduction of ASDH may occur in some patients. The mechanisms are most likely the result of dilution by cerebrospinal fluid and the redistribution of hematoma especially in patients with brain atrophy. PMID:19949689
NASA Astrophysics Data System (ADS)
Jang, Yujin; Hong, Helen; Chung, Jin Wook; Yoon, Young Ho
2012-02-01
We propose an effective technique for the extraction of liver boundary based on multi-planar anatomy and deformable surface model in abdominal contrast-enhanced CT images. Our method is composed of four main steps. First, for extracting an optimal volume circumscribing a liver, lower and side boundaries are defined by positional information of pelvis and rib. An upper boundary is defined by separating the lungs and heart from CT images. Second, for extracting an initial liver volume, optimal liver volume is smoothed by anisotropic diffusion filtering and is segmented using adaptively selected threshold value. Third, for removing neighbor organs from initial liver volume, morphological opening and connected component labeling are applied to multiple planes. Finally, for refining the liver boundaries, deformable surface model is applied to a posterior liver surface and missing left robe in previous step. Then, probability summation map is generated by calculating regional information of the segmented liver in coronal plane, which is used for restoring the inaccurate liver boundaries. Experimental results show that our segmentation method can accurately extract liver boundaries without leakage to neighbor organs in spite of various liver shape and ambiguous boundary.
Femoral head avascular necrosis: a frequently missed incidental finding on multidetector CT.
Barille, M F; Wu, Jim S; McMahon, Colm J
2014-03-01
To determine the incidence of missed femoral head avascular necrosis (AVN) on pelvic computed tomography (CT) performed for clinical indications other than assessment for AVN. The study was a Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study. The picture archiving and communication system (PACS) database was queried for patients with diagnosis of femoral head AVN on magnetic resonance imaging (MRI), who also underwent pelvic multidetector CT after or <30 days before the MRI examination. The MRI and CT images of 144 hips of 72 patients (39 patients with reported AVN on MRI and 33 age-matched controls; mean age = 60 years, 28 male, 44 female), were reviewed in consensus by two readers in a randomized, blinded manner. Using MRI-proven CT-visible AVN as a reference standard, the incidence of missed AVN on initial CT interpretation was determined. Readers confirmed AVN in 33 patients on the MRI images. Nine hips with AVN underwent joint replacement of the affected joint(s) prior to subsequent CT and were excluded. Forty-three MRI-proven AVN cases in 28 patients (15 bilateral, 13 unilateral) were available for analysis. The study readers diagnosed 35/43 (81%) MRI-proven AVN cases in 22/28 (79%) patients. Four of the 35 (11%) cases of MRI-proven, CT-visible AVN were prospectively reported in 3/22 (14%) patients at initial clinical interpretation, with a miss rate of 89% per hip and 86% per patient. Multidetector CT has high accuracy for detection of AVN; however, this is frequently missed as an incidental finding (89% missed in the present study). Assessment for signs of femoral AVN should be part of routine search pattern in interpretation of pelvic CT. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
The diagnostic challenge of the sequelae of acute pancreatitis on CT imaging: a pictorial essay.
Hughey, Mark; Taffel, Myles; Zeman, Robert K; Patel, Smita; Hill, Michael C
2017-04-01
The purpose of the study was to present a pictorial review of the long-term sequelae of acute pancreatitis on CT imaging as these findings can cause diagnostic confusion in the absence of a proper clinical history and/or prior CT imaging. We retrospectively identified 81 patients who had an episode of acute pancreatitis with diagnostic findings on CT and also underwent one or more follow-up CT scans at least 1 month beyond the acute episode. The residual findings on all follow-up CT scans were tabulated, including the time interval since the initial bout of acute pancreatitis. Residual inflammatory changes were present in 19.8% of cases, with a median time period lasting 86 days since the initial episode of acute pancreatitis. Residual fluid collections were seen in 27.2% and persisted for a median of 132 days. Three patients had residual solid-appearing inflammatory masses, which could be mistaken for neoplasms. Other long-term sequelae were also tabulated, including pancreatic ductal dilatation, pancreatic atrophy, new or increased pancreatic calcifications, biliary tract dilatation, central portal venous occlusion, and pseudoaneurysm formation. These residual findings and long-term complications are presented as a pictorial essay. Recognizing the spectrum of residual findings of acute pancreatitis, some of which can be long term, is important in the correct interpretation of a pancreatic CT. These findings can mimic acute pancreatitis or a pancreatic/peripancreatic neoplasm and often cause diagnostic confusion, especially in the absence of prior CT imaging.
Microstructural examination of fatigue crack tip in high strength steel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fukuoka, C.; Yoshizawa, H.; Nakagawa, Y.G.
1993-10-01
Fatigue tests were performed to examine how microstructural conditioning influences crack initiation and propagation in SA508 class 3 low-carbon steel. A 3-mm-long crack was introduced in compact tension (CT) fatigue test specimens under four different loads in order to obtain crack tip plastic zones at different stress intensity factor ranges, [Delta]K = 18, 36, 54, and 72 MPa[radical]m. The microstructure of the plastic zones around the crack tip were examined by transmission electron microscopy (TEM) and selected area electron diffraction (SAD). Micro-orientation of the dislocation cells in the plastic zones of all of the CT samples increased to 4 degmore » from the level of an as-received sample. Four-point bending fatigue tests were performed for plate shape samples with a large cyclic strain range. The SAD value of the bending samples was also 4 deg in the damaged area where cracks already initiated at an early stage of the fatigue process. These test results indicate that the microstructural conditioning is a prerequisite for the fatigue crack initiation and propagation in SA508. These observations may lead to better understanding of how fatigue initiation processes transit to cracks.« less
The ability of computed tomography to diagnose placental abruption in the trauma patient.
Kopelman, Tammy R; Berardoni, Nicole E; Manriquez, Maria; Gridley, Daniel; Vail, Sydney J; Pieri, Paola G; O'Neill; Pressman, Melissa A
2013-01-01
Fetal demise following trauma remains a devastating complication largely owing to placental injury and abruption. Our objective was to determine if abdominopelvic computed tomographic (CT) imaging can assess for placental abruption (PA) when obtained to exclude associated maternal injuries. Retrospective review of pregnant trauma patients of 20-week gestation or longer presenting to a trauma center during a 7-year period who underwent CT imaging as part of their initial evaluation. Radiographic images were reviewed by a radiologist for evidence of PA and classified based on percentage of visualized placental enhancement. Blinded to CT results, charts were reviewed by an obstetrician for clinical evidence of PA and classified as strongly positive, possibly positive, or no evidence. A total of 176 patients met inclusion criteria. CT imaging revealed evidence of PA in 61 patients (35%). As the percentage of placental enhancement decreased, patients were more likely to have strong clinical manifestations of PA, reaching statistical significance when enhancement was less than 50%. CT imaging evidence of PA was apparent in all patients who required delivery for nonassuring fetal heart tones. CT imaging evaluation of the placenta can accurately identify PA and therefore can help stratify patients at risk for fetal complications. The likelihood of requiring delivery increased as placental enhancement declined to less than 25%. Diagnostic study, level III.
NASA Astrophysics Data System (ADS)
Nadeem, Syed Ahmed; Hoffman, Eric A.; Sieren, Jered P.; Saha, Punam K.
2018-03-01
Numerous large multi-center studies are incorporating the use of computed tomography (CT)-based characterization of the lung parenchyma and bronchial tree to understand chronic obstructive pulmonary disease status and progression. To the best of our knowledge, there are no fully automated airway tree segmentation methods, free of the need for user review. A failure in even a fraction of segmentation results necessitates manual revision of all segmentation masks which is laborious considering the thousands of image data sets evaluated in large studies. In this paper, we present a novel CT-based airway tree segmentation algorithm using topological leakage detection and freeze-and-grow propagation. The method is fully automated requiring no manual inputs or post-segmentation editing. It uses simple intensity-based connectivity and a freeze-and-grow propagation algorithm to iteratively grow the airway tree starting from an initial seed inside the trachea. It begins with a conservative parameter and then, gradually shifts toward more generous parameter values. The method was applied on chest CT scans of fifteen subjects at total lung capacity. Airway segmentation results were qualitatively assessed and performed comparably to established airway segmentation method with no major visual leakages.
CT imaging, then and now: a 30-year review of the economics of computed tomography.
Stockburger, Wayne T
2004-01-01
The first computed tomography (CT) scanner in the US was installed in June 1973 at the Mayo Clinic in Rochester, MN. By the end of 1974, 44 similar systems had been installed at medical facilities around the country. Less than 4 years after the introduction of CT imaging in the US, at least 400 CT systems had been installed. The practice of pneumoencephalography was eliminated. The use of nuclear medicine brain scans significantly diminished. At the time, CT imaging was limited to head studies, but with the introduction of contrast agents and full body CT systems the changes in the practice of medicine became even more significant. CT imaging was hailed by the US medical community as the greatest advance in radiology since the discovery of x-rays. But the rapid spread of CT systems, their frequency of use, and the associated increase in healthcare costs combined to draw the attention of decision-makers within the federal and state governments, specifically to establish policies regarding the acquisition and use of diagnostic technologies. Initially, CT imaging was limited to neurological applications, but in the 30 years since its inception, capabilities and applications have been expanded as a result of the advancements in technology and software development. While neurological disorders are still a common reason for CT imaging, many other medical disciplines (oncology, emergency medicine, orthopedics, etc.) have found CT imaging to be the definitive tool for diagnostic information. As such, the clinical demand for CT imaging has steadily increased. Economically, the development of CT imaging has been one of success, even in the face of governmental action to restrict its acquisition and utilization by healthcare facilities. CTimaging has increased the cost of healthcare, but in turn has added unquantifiable value to the practice of medicine in the US.
Cecocentral scotoma as the initial manifestation of subacute bacterial endocarditis
Strauss, Danielle Savitsky; Baharestani, Samuel; Nemiroff, Julia; Amesur, Kiran; Howard, David
2011-01-01
Introduction: We report a case of a 67-year-old male who presented with a cecocentral scotoma caused by a septic embolus from subacute bacterial endocarditis (SBE). Methods: A 67-year-old man presented with sudden, painless decreased vision in the left eye. A dilated fundoscopic exam, Humphrey visual field test, transthoracic echocardiogram, abdominal computed tomography (CT), and blood cultures were all performed. Results: A dilated fundoscopic exam revealed temporal segmental optic disc pallor on the left, and Humphrey visual field testing demonstrated a dense left cecocentral scotoma. When the patient developed fever (103. 9°F) and palpitations, transthoracic echocardiogram revealed valvular vegetations, and contrast CT of the abdomen revealed an abscess in the dome of the liver likely due to an infectious thrombus. Blood cultures grew viridians group streptococci in three separate peripheral collections. Conclusion: This case illustrates that a sudden cecocentral scotoma may be the initial manifestation of SBE. PMID:21468335
SU-F-T-92: Clinical Benefit for Breast and Chest Wall Setup in Using a Breast Board
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, S; Miyamoto, C; Serratore, D
Purpose: To validate benefit of using a breast board (BB) by analyzing the geometry and dosimetry changes of the regions of interest (ROIs) between CT scans with and without BB. Methods: Seven patients, two chest walls (CW) and five breasts, use BB at CT simulation and no BB at diagnostic CT were included. By using deformable image registration software (Velocity AI), diagnostic CT and planning CT were rigidly co-registered according to the thoracic cage at the target. The heart and the target were then deformedly matched and the contours of the planned ROIs were transferred to the diagnostic CT. Whichmore » were brought back to the planning CT data set though the initial rigid co-registration in order to keep the deformed ROIs redefined in the diagnostic CT. Anatomic shifts and volume changes of a ROI beyond the rigid translation were recorded and dosimetry changes to ROIs were compared with recalculated DVHs. Results: Patient setup without the BB had small but systematic heart shifts superiorly by ∼5 mm. Torso rotations in two cases moved the heart in opposite directions by ∼10 mm. The breast target volume, shape, and locations were significantly changed with arm extension over the head but not in cases with the arm extended laterally. Breast setup without BB could increase the mean dose to the heart and the maximal dose to the anterior ventricle wall by 1.1 and 6.7 Gy, respectively. Conclusion: A method for evaluation of breast setup technique is introduced and applied for patients. Results of systematic heart displacement without using the BB and the potential increase of heart doses encourage us to further investigate the current trend of not using a BB for easy setup and CT scans. Using a BB would likely increase patient sag during prolonged IMRT and real-time patient position monitoring is clinically desired.« less
Patel, Mayur B.; Humble, Stephen S.; Cullinane, Daniel C.; Day, Matthew A.; Jawa, Randeep S.; Devin, Clinton J.; Delozier, Margaret S.; Smith, Lou M.; Smith, Miya A.; Capella, Jeannette M.; Long, Andrea M.; Cheng, Joseph S.; Leath, Taylor C.; Falck-Ytter, Yngve; Haut, Elliott R.; Como, John J.
2015-01-01
BACKGROUND With the use of the framework advocated by the Grading of Recommendations Assessment, Development and Evaluation (GRADE) Working Group, our aims were to perform a systematic review and to develop evidence-based recommendations that may be used to answer the following PICO [Population, Intervention, Comparator, Outcomes] question: In the obtunded adult blunt trauma patient, should cervical collar removal be performed after a negative high-quality cervical spine (C-spine) computed tomography (CT) result alone or after a negative high-quality C-spine CT result combined with adjunct imaging, to reduce peri-clearance events, such as new neurologic change, unstable C-spine injury, stable C-spine injury, need for post-clearance imaging, false-negative CT imaging result on re-review, pressure ulcers, and time to cervical collar clearance? METHODS Our protocol was registered with the PROSPERO international prospective register of systematic reviews on August 23, 2013 (Registration Number: CRD42013005461). Eligibility criteria consisted of adult blunt trauma patients 16 years or older, who underwent C-spine CT with axial thickness of less than 3 mm and who were obtunded using any definition. Quantitative synthesis via meta-analysis was not possible because of pre-post, partial-cohort, quasi-experimental study design limitations and the consequential incomplete diagnostic accuracy data. RESULTS Of five articles with a total follow-up of 1,017 included subjects, none reported new neurologic changes (paraplegia or quadriplegia) after cervical collar removal. There is a worst-case 9% (161 of 1,718 subjects in 11 studies) cumulative literature incidence of stable injuries and a 91% negative predictive value of no injury, after coupling a negative high-quality C-spine CT result with 1.5-T magnetic resonance imaging, upright x-rays, flexion-extension CT, and/or clinical follow-up. Similarly, there is a best-case 0% (0 of 1,718 subjects in 11 studies) cumulative literature incidence of unstable injuries after negative initial imaging result with a high-quality C-spine CT. CONCLUSION In obtunded adult blunt trauma patients, we conditionally recommend cervical collar removal after a negative high-quality C-spine CT scan result alone. LEVEL OF EVIDENCE Systematic review, level III. PMID:25757133
DOE Office of Scientific and Technical Information (OSTI.GOV)
La Fontaine, M; Bradshaw, T; Kubicek, L
2014-06-15
Purpose: Regions of poor perfusion within tumors may be associated with higher hypoxic levels. This study aimed to test this hypothesis by comparing measurements of hypoxia from Cu-ATSM PET to vasculature kinetic parameters from DCE-CT kinetic analysis. Methods: Ten canine patients with sinonasal tumors received one Cu-ATSM PET/CT scan and three DCE-CT scans prior to treatment. Cu-ATSM PET/CT and DCE-CT scans were registered and resampled to matching voxel dimensions. Kinetic analysis was performed on DCE-CT scans and for each patient, the resulting kinetic parameter values from the three DCE-CT scans were averaged together. Cu-ATSM SUVs were spatially correlated (r{sub spatial})more » on a voxel-to-voxel basis against the following DCE-CT kinetic parameters: transit time (t{sub 1}), blood flow (F), vasculature fraction (v{sub 1}), and permeability (PS). In addition, whole-tumor comparisons were performed by correlating (r{sub ROI}) the mean Cu-ATSM SUV (SUV{sub mean}) with median kinetic parameter values. Results: The spatial correlations (r{sub spatial}) were poor and ranged from -0.04 to 0.21 for all kinetic parameters. These low spatial correlations may be due to high variability in the DCE-CT kinetic parameter voxel values between scans. In our hypothesis, t{sub 1} was expected to have a positive correlation, while F was expected to have a negative correlation to hypoxia. However, in wholetumor analysis the opposite was found for both t{sub 1} (r{sub ROI} = -0.25) and F (r{sub ROI} = 0.56). PS and v{sub 1} may depict angiogenic responses to hypoxia and found positive correlations to Cu-ATSM SUV for PS (r{sub ROI} = 0.41), and v{sub 1} (r{sub ROI} = 0.57). Conclusion: Low spatial correlations were found between Cu-ATSM uptake and DCE-CT vasculature parameters, implying that poor perfusion is not associated with higher hypoxic regions. Across patients, the most hypoxic tumors tended to have higher blood flow values, which is contrary to our initial hypothesis. Funding: R01 CA136927.« less
NASA Astrophysics Data System (ADS)
Jechel, Christopher Alexander
In radiotherapy planning, computed tomography (CT) images are used to quantify the electron density of tissues and provide spatial anatomical information. Treatment planning systems use these data to calculate the expected spatial distribution of absorbed dose in a patient. CT imaging is complicated by the presence of metal implants which cause increased image noise, produce artifacts throughout the image and can exceed the available range of CT number values within the implant, perturbing electron density estimates in the image. Furthermore, current dose calculation algorithms do not accurately model radiation transport at metal-tissue interfaces. Combined, these issues adversely affect the accuracy of dose calculations in the vicinity of metal implants. As the number of patients with orthopedic and dental implants grows, so does the need to deliver safe and effective radiotherapy treatments in the presence of implants. The Medical Physics group at the Cancer Centre of Southeastern Ontario and Queen's University has developed a Cobalt-60 CT system that is relatively insensitive to metal artifacts due to the high energy, nearly monoenergetic Cobalt-60 photon beam. Kilovoltage CT (kVCT) images, including images corrected using a commercial metal artifact reduction tool, were compared to Cobalt-60 CT images throughout the treatment planning process, from initial imaging through to dose calculation. An effective metal artifact reduction algorithm was also implemented for the Cobalt-60 CT system. Electron density maps derived from the same kVCT and Cobalt-60 CT images indicated the impact of image artifacts on estimates of photon attenuation for treatment planning applications. Measurements showed that truncation of CT number data in kVCT images produced significant mischaracterization of the electron density of metals. Dose measurements downstream of metal inserts in a water phantom were compared to dose data calculated using CT images from kVCT and Cobalt-60 systems with and without artifact correction. The superior accuracy of electron density data derived from Cobalt-60 images compared to kVCT images produced calculated dose with far better agreement with measured results. These results indicated that dose calculation errors from metal image artifacts are primarily due to misrepresentation of electron density within metals rather than artifacts surrounding the implants.
NASA Astrophysics Data System (ADS)
Zhang, Hao; Gang, Grace J.; Lee, Junghoon; Wong, John; Stayman, J. Webster
2017-03-01
Purpose: There are many clinical situations where diagnostic CT is used for an initial diagnosis or treatment planning, followed by one or more CBCT scans that are part of an image-guided intervention. Because the high-quality diagnostic CT scan is a rich source of patient-specific anatomical knowledge, this provides an opportunity to incorporate the prior CT image into subsequent CBCT reconstruction for improved image quality. We propose a penalized-likelihood method called reconstruction of difference (RoD), to directly reconstruct differences between the CBCT scan and the CT prior. In this work, we demonstrate the efficacy of RoD with clinical patient datasets. Methods: We introduce a data processing workflow using the RoD framework to reconstruct anatomical changes between the prior CT and current CBCT. This workflow includes processing steps to account for non-anatomical differences between the two scans including 1) scatter correction for CBCT datasets due to increased scatter fractions in CBCT data; 2) histogram matching for attenuation variations between CT and CBCT; and 3) registration for different patient positioning. CBCT projection data and CT planning volumes for two radiotherapy patients - one abdominal study and one head-and-neck study - were investigated. Results: In comparisons between the proposed RoD framework and more traditional FDK and penalized-likelihood reconstructions, we find a significant improvement in image quality when prior CT information is incorporated into the reconstruction. RoD is able to provide additional low-contrast details while correctly incorporating actual physical changes in patient anatomy. Conclusions: The proposed framework provides an opportunity to either improve image quality or relax data fidelity constraints for CBCT imaging when prior CT studies of the same patient are available. Possible clinical targets include CBCT image-guided radiotherapy and CBCT image-guided surgeries.
Delayed hydronephrosis due to retroperitoneal hematoma after a seatbelt injury: A case report.
Yumoto, Tetsuya; Kondo, Yoshitaka; Kumon, Kento; Masaoka, Yoshihisa; Hiraki, Takao; Yamada, Taihei; Naito, Hiromichi; Nakao, Atsunori
2018-06-01
Hydronephrosis caused by retroperitoneal hematoma after a seatbelt injury is a unique clinical entity. A 21-year-old man, who had been wearing a seatbelt, was brought to our hospital after a motor vehicle collision, complaining of abdominal pain. Computed tomography (CT) revealed retroperitoneal hematoma in the upper pelvic region. Since he was hemodynamically stable throughout admission, he was managed conservatively. Seventeen days after initial discharge, the patient revisited our emergency department due to right back pain. CT scans indicated retroperitoneal hematoma growth resulting in hydronephrosis of the right kidney. Laparoscopic drainage of the retroperitoneal hematoma was successfully performed. His symptoms resolved after the surgery. Follow-up CT scans three months later demonstrated complete resolution of the hydronephrosis and retroperitoneal hematoma. Our case highlights a patient with delayed hydronephrosis because of retroperitoneal hematoma expansion after a seatbelt injury.
Minor head injury in children.
Klig, Jean E; Kaplan, Carl P
2010-06-01
This review will examine mild closed head injury (CHI) and the current evidence on head computed tomography (CT) imaging risks in children, prediction rules to guide decisions on CT scan use, and issues of concussion after initial evaluation. The current literature offers preliminary evidence on the risks of radiation exposure from CT scans in children. A recent study introduces a validated prediction rule for use in mild CHI, to limit the number of CT scans performed. Concurrent with this progress, fast (or short sequence) MRI represents an emerging technology that may prove to be a viable alternative to CT scan use in certain cases of mild CHI where imaging is desired. The initial emergency department evaluation for mild CHI is the start point for a sequence of follow-up to assure that postconcussive symptoms fully resolve. The literature on sports-related concussion offers some information that may be used for patients with non-sports-related concussion. It is clear that CT scan use should be as safe and limited in scope as possible for children. Common decisions on the use of CT imaging for mild head injury can now be guided by a prediction rule for clinically important traumatic brain injury. Parameters for the follow-up care of patients with mild CHI after emergency department discharge are needed in the future to assure that postconcussive symptoms are adequately screened for full resolution.
NASA Astrophysics Data System (ADS)
Mahler, B. J.; Van Metre, P. C.; Ingersoll, C.; Kunz, J. L.
2014-12-01
Coal-tar (CT) sealcoat, a potent source of polycyclic aromatic hydrocarbons (PAHs) and N-heterocycles, is applied to asphalt pavement of parking lots and driveways in many parts of the U.S. and Canada every 1 to 5 years. We measured the chemistry and toxicity of unfiltered runoff resulting from rain events simulated from 5 hours to 111 days after application of CT or asphalt (AS) sealcoat. PAHs and N-heterocycles were measured by GC/EIMS. Toxicity tests were done with Ceriodaphnia dubia and Pimephales promelas exposed 48 hours to undiluted and diluted (1 part runoff 9 parts control water) runoff under ambient lighting. Organisms were then transferred to fresh control water and subjected to a 4-hour pulse of ultraviolet radiation (UVR). Concentrations of 2- and 3-ringed PAHs and N-heterocycles in CT runoff, initially high (sum of 6 PAHs, 220 μg/L; sum of 7 N-heterocycles, 904 μg/L), decreased rapidly, whereas concentrations of 4-, 5- and 6-ringed PAHs more than doubled by 7 days after application (sum of 9 PAHs, 378 μg/L) and remained elevated 111 days after application (sum of 9 PAHs, 283 μg/L). Concentrations of PAHs and N-heterocycles in AS sealcoated runoff followed a similar pattern, but were ~10 times lower than those in CT runoff; concentrations in a sample of runoff from unsealed asphalt pavement were near or less than the detection limit. Organisms exposed to samples of undiluted CT-runoff collected during the 36 days following CT sealcoat application (no UVR exposure) experienced 100% mortality. Mortality (as much as 100%) of organisms exposed to the 10% dilution of CT runoff or to undiluted AS runoff occurred only with UVR; mortality of organisms exposed to the 10% solution of AS runoff and UVR was minimal. Results demonstrate that freshly CT-sealed parking lots and driveways are "hot spots" of PAH and N-heterocycle contamination and that prolonged "hot moments" of toxicity follow CT sealcoat application.
Smoking cessation results in a clinical lung cancer screening program
McKee, Andrea B.; Regis, Shawn M.; Wald, Christoph; Flacke, Sebastian; McKee, Brady J.
2016-01-01
Background Lung cancer screening may provide a “teachable moment” for promoting smoking cessation. This study assessed smoking cessation and relapse rates among individuals undergoing follow-up low-dose chest computed tomography (CT) in a clinical CT lung screening program and assessed the influence of initial screening results on smoking behavior. Methods Self-reported smoking status for individuals enrolled in a clinical CT lung screening program undergoing a follow-up CT lung screening exam between 1st February, 2014 and 31st March, 2015 was retrospectively reviewed and compared to self-reported smoking status using a standardized questionnaire at program entry. Point prevalence smoking cessation and relapse rates were calculated across the entire population and compared with exam results. All individuals undergoing screening fulfilled the National Comprehensive Cancer Network Clinical Practice Guidelines in Oncology: Lung Cancer Screening v1.2012® high-risk criteria and had an order for CT lung screening. Results A total of 1,483 individuals underwent a follow-up CT lung screening exam during the study interval. Smoking status at time of follow-up exam was available for 1,461/1,483 (98.5%). A total of 46% (678/1,461) were active smokers at program entry. The overall point prevalence smoking cessation and relapse rates were 20.8% and 9.3%, respectively. Prior positive screening exam results were not predictive of smoking cessation (OR 1.092; 95% CI, 0.715–1.693) but were predictive of reduced relapse among former smokers who had stopped smoking for 2 years or less (OR 0.330; 95% CI, 0.143–0.710). Duration of program enrollment was predictive of smoking cessation (OR 0.647; 95% CI, 0.477–0.877). Conclusions Smoking cessation and relapse rates in a clinical CT lung screening program rates are more favorable than those observed in the general population. Duration of participation in the screening program correlated with increased smoking cessation rates. A positive exam result correlated with reduced relapse rates among smokers recently quit smoking. PMID:27606076
Clinical Use of CT Perfusion For Diagnosis and Prediction of Lesion Growth in Acute Ischemic Stroke
Huisa, Branko N; Neil, William P; Schrader, Ronald; Maya, Marcel; Pereira, Benedict; Bruce, Nhu T; Lyden, Patrick D
2012-01-01
Background and Purpose CT perfusion (CTP) mapping in research centers correlates well with diffusion weighted imaging (DWI) lesions and may accurately differentiate the infarct core from ischemic penumbra. The value of CTP in real-world clinical practice has not been fully established. We investigated the yield of CTP– derived cerebral blood volume (CBV) and mean transient time (MTT) for the detection of cerebral ischemia and ischemic penumbra in a sample of acute ischemic stroke (AIS) patients. Methods We studied 165 patients with initial clinical symptoms suggestive of AIS. All patients had an initial non-contrast head CT, CT Perfusion (CTP), CT angiogram (CTA) and follow up brain MRI. The obtained perfusion images were used for image processing. CBV, MTT and DWI lesion volumes were visually estimated and manually traced. Statistical analysis was done using R-2.14.and SAS 9.1. Results All normal DWI sequences had normal CBV and MTT studies (N=89). Seventy-three patients had acute DWI lesions. CBV was abnormal in 23.3% and MTT was abnormal in 42.5% of these patients. There was a high specificity (91.8%)but poor sensitivity (40.0%) for MTT maps predicting positive DWI. Spearman correlation was significant between MTT and DWI lesions (ρ=0.66, p>0.0001) only for abnormal MTT and DWI lesions>0cc. CBV lesions did not correlate with final DWI. Conclusions In real-world use, acute imaging with CTP did not predict stroke or DWI lesions with sufficient accuracy. Our findings argue against the use of CTP for screening AIS patients until real-world implementations match the accuracy reported from specialized research centers. PMID:23253533
Dual-contrast agent photon-counting computed tomography of the heart: initial experience.
Symons, Rolf; Cork, Tyler E; Lakshmanan, Manu N; Evers, Robert; Davies-Venn, Cynthia; Rice, Kelly A; Thomas, Marvin L; Liu, Chia-Ying; Kappler, Steffen; Ulzheimer, Stefan; Sandfort, Veit; Bluemke, David A; Pourmorteza, Amir
2017-08-01
To determine the feasibility of dual-contrast agent imaging of the heart using photon-counting detector (PCD) computed tomography (CT) to simultaneously assess both first-pass and late enhancement of the myocardium. An occlusion-reperfusion canine model of myocardial infarction was used. Gadolinium-based contrast was injected 10 min prior to PCD CT. Iodinated contrast was infused immediately prior to PCD CT, thus capturing late gadolinium enhancement as well as first-pass iodine enhancement. Gadolinium and iodine maps were calculated using a linear material decomposition technique and compared to single-energy (conventional) images. PCD images were compared to in vivo and ex vivo magnetic resonance imaging (MRI) and histology. For infarct versus remote myocardium, contrast-to-noise ratio (CNR) was maximal on late enhancement gadolinium maps (CNR 9.0 ± 0.8, 6.6 ± 0.7, and 0.4 ± 0.4, p < 0.001 for gadolinium maps, single-energy images, and iodine maps, respectively). For infarct versus blood pool, CNR was maximum for iodine maps (CNR 11.8 ± 1.3, 3.8 ± 1.0, and 1.3 ± 0.4, p < 0.001 for iodine maps, gadolinium maps, and single-energy images, respectively). Combined first-pass iodine and late gadolinium maps allowed quantitative separation of blood pool, scar, and remote myocardium. MRI and histology analysis confirmed accurate PCD CT delineation of scar. Simultaneous multi-contrast agent cardiac imaging is feasible with photon-counting detector CT. These initial proof-of-concept results may provide incentives to develop new k-edge contrast agents, to investigate possible interactions between multiple simultaneously administered contrast agents, and to ultimately bring them to clinical practice.
Beck-Razi, Nira; Fischer, Doron; Michaelson, Moshe; Engel, Ahuva; Gaitini, Diana
2007-09-01
The purpose of this study was to evaluate the role of focused assessment with sonography for trauma (FAST) as a triage tool in multiple-casualty incidents (MCIs) for a single international conflict. The charts of 849 casualties that arrived at our level 1 trauma referral center were reviewed. Casualties were initially triaged according to the Injury Severity Score at the emergency department gate. Two-hundred eighty-one physically injured patients, 215 soldiers (76.5%) and 66 civilians (23.5%), were admitted. Focused assessment with sonography for trauma was performed in 102 casualties suspected to have an abdominal injury. Sixty-eight underwent computed tomography (CT); 12 underwent laparotomy; and 28 were kept under clinical observation alone. We compared FAST results against CT, laparotomy, and clinical observation records. Focused assessment with sonography for trauma results were positive in 17 casualties and negative in 85. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FAST were 75%, 97.6%, 88.2%, 94.1%, and 93.1%, respectively. A strong correlation between FAST and CT results, laparotomy, and clinical observation was obtained (P < .05). In a setting of a war conflict-related MCI, FAST enabled immediate triage of casualties to laparotomy, CT, or clinical observation. Because of its moderate sensitivity, a negative FAST result with strong clinical suspicion demands further evaluation, especially in an MCI.
CT findings in ulcerative, granulomatous, and indeterminate colitis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gore, R.M.; Marn, C.S.; Kirby, D.F.
1984-08-01
Eight patients with ulcerative colitis, three with colitis indeterminate, and 15 patients with Crohn disease were studied by computed tomography (CT) to establish CT criteria for each disorder in hopes of providing a new diagnostic perspective useful in the radiographic evaluation of inflammatory colitis. The CT findings in ulcerative colitis included thickening of the colon wall, which was characterized by inhomogeneous attenuation and a target appearance of the rectum, and proliferation of perirectal fat. Bowel wall thickening with homogeneous attenuation, fistula and abscess formation, and mesenteric abnormalities were observed in patients with Crohn colitis. Patients with colitis indeterminate showed colonicmore » changes on CT observed in both disorders. Initial experience suggests that CT can differentiate patients with well established ulcerative and Crohn colitis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moriya, S; National Cancer Center, Kashiwa, Chiba; Tachibana, H
Purpose: Daily CT-based three-dimensional image-guided and adaptive (CTIGRT-ART) proton therapy system was designed and developed. We also evaluated the effectiveness of the CTIGRT-ART. Methods: Retrospective analysis was performed in three lung cancer patients: Proton treatment planning was performed using CT image datasets acquired by Toshiba Aquilion ONE. Planning target volume and surrounding organs were contoured by a well-trained radiation oncologist. Dose distribution was optimized using 180-deg. and 270-deg. two fields in passive scattering proton therapy. Well commissioned Simplified Monte Carlo algorithm was used as dose calculation engine. Daily consecutive CT image datasets was acquired by an in-room CT (Toshiba Aquilionmore » LB). In our in-house program, two image registrations for bone and tumor were performed to shift the isocenter using treatment CT image dataset. Subsequently, dose recalculation was performed after the shift of the isocenter. When the dose distribution after the tumor registration exhibits change of dosimetric parameter of CTV D90% compared to the initial plan, an additional process of was performed that the range shifter thickness was optimized. Dose distribution with CTV D90% for the bone registration, the tumor registration only and adaptive plan with the tumor registration was compared to the initial plan. Results: In the bone registration, tumor dose coverage was decreased by 16% on average (Maximum: 56%). The tumor registration shows better coverage than the bone registration, however the coverage was also decreased by 9% (Maximum: 22%) The adaptive plan shows similar dose coverage of the tumor (Average: 2%, Maximum: 7%). Conclusion: There is a high possibility that only image registration for bone and tumor may reduce tumor coverage. Thus, our proposed methodology of image guidance and adaptive planning using the range adaptation after tumor registration would be effective for proton therapy. This research is partially supported by Japan Agency for Medical Research and Development (AMED).« less
DICOM structured report to track patient's radiation dose to organs from abdominal CT exam
NASA Astrophysics Data System (ADS)
Morioka, Craig; Turner, Adam; McNitt-Gray, Michael; Zankl, Maria; Meng, Frank; El-Saden, Suzie
2011-03-01
The dramatic increase of diagnostic imaging capabilities over the past decade has contributed to increased radiation exposure to patient populations. Several factors have contributed to the increase in imaging procedures: wider availability of imaging modalities, increase in technical capabilities, rise in demand by patients and clinicians, favorable reimbursement, and lack of guidelines to control utilization. The primary focus of this research is to provide in depth information about radiation doses that patients receive as a result of CT exams, with the initial investigation involving abdominal CT exams. Current dose measurement methods (i.e. CTDIvol Computed Tomography Dose Index) do not provide direct information about a patient's organ dose. We have developed a method to determine CTDIvol normalized organ doses using a set of organ specific exponential regression equations. These exponential equations along with measured CTDIvol are used to calculate organ dose estimates from abdominal CT scans for eight different patient models. For each patient, organ dose and CTDIvol were estimated for an abdominal CT scan. We then modified the DICOM Radiation Dose Structured Report (RDSR) to store the pertinent patient information on radiation dose to their abdominal organs.
The Beatles, the Nobel Prize, and CT scanning of the chest.
Goodman, Lawrence R
2010-01-01
From its first test scan on a mouse, in 1967, to current medical practice, the CT scanner has become a core imaging tool in thoracic diagnosis. Initially financed by money from Beatles' record sales, the first patient scan was performed in 1971. Only 8 years later, a Nobel Prize in Physics and Medicine was awarded to Hounsfield and Cormack for their discovery. This article traces the history of CT scanner development and how each technical advance expanded chest diagnostic frontiers. Chest imaging now accounts for 30% of all CT scanning.
In-Iw, Supinya; Braverman, Paula K; Bates, Justin R; Biro, Frank M
2015-12-01
To evaluate the effectiveness of a sexually transmitted infection (STI) intervention by a health educator that included partner notification, condom use, and retesting within 3 months. Retrospective chart review was conducted, and data were collected from 274 sexually active adolescent girls, aged 15 to 19 years, who were diagnosed with gonorrhea (GC), Chlamydia (CT), and Trichomonas (TV) infection, during a 9-month span in an urban hospital-based adolescent medicine clinic. Data regarding recurrent STIs (GC, CT, and TV) were collected for 12 months following the incident infection. There were 161 in the intervention group (health educator counseling), and 113 controls who received usual care. Differences between groups were analyzed using χ(2) and survival analyses. There were no significant differences in age, gender, or race between the intervention and control groups at baseline. The majority in both groups were diagnosed initially with CT infection (57% CT, 16% GC, and 5% TV in the intervention group; 46% CT, 21% GC, and 12% TV in the control group). There was a significantly lower rate of STI in the intervention group for those retested within 12 months of the initial diagnosis (P = .002). The median (SD) time to recurrence in the intervention group was greater: 134 (14.7) days versus 116 (12.1) days (P = .034). Health education counseling, initial diagnosis with TV, and duration of time from initial diagnosis to retest (interval to retest) were significant protective factors for recurrent STI. Health education counseling in an urban adolescent clinic is effective in reducing recurrent infection at 12-month follow-up and can serve as an important component in reducing STI recidivism. Copyright © 2015 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Schlenkhoff, Carl Diedrich; Gaertner, Florian; Essler, Markus; Hauser, Stefan; Ahmadzadehfar, Hojjat
2016-05-01
Prostate cancer was diagnosed in a 71-year-old man with an elevated prostate-specific antigen. The CT of the abdomen showed multiple para-aortal lymph nodes, and thus, a Ga anti-prostate-specific membrane antigen (PSMA-11) PET/CT was initiated, which showed, aside from the prostate cancer and multiple iliacal and para-aortal lymph node metastases, an increased tracer uptake in a lymph node left cervical. According to this advanced disease, a palliative therapy with GnRH agonist was initiated. A second PSMA-11 PET/CT was performed 4 months later, which showed a very good response; thus, additional radiation of the pelvis and the draining lymphatic system was performed.
Lee, Jeong Woo; Kim, Ho Gak; Lee, Dong Wook; Han, Jimin; Kwon, Hyuk Yong; Seo, Chang Jin; Oh, Ji Hye; Lee, Joo Hyoung; Jung, Jin Tae; Kwon, Joong Goo; Kim, Eun Young
2016-05-23
Smoking and alcohol intake are two wellknown risk factors for chronic pancreatitis. However, there are few studies examining the association between smoking and changes in computed tomography (CT) findings in chronic pancreatitis. The authors evaluated associations between smoking, drinking and the progression of calcification on CT in chronic pancreatitis. In this retrospective study, 59 patients with chronic pancreatitis who had undergone initial and follow-up CT between January 2002 and September 2010 were included. Progression of calcification among CT findings was compared according to the amount of alcohol intake and smoking. The median duration of followup was 51.6 months (range, 17.1 to 112.7 months). At initial CT findings, there was pancreatic calcification in 35 patients (59.3%). In the follow-up CT, progression of calcification was observed in 37 patients (62.7%). Progression of calcification was more common in smokers according to the multivariate analysis (odds ratio [OR], 9.987; p=0.006). The amount of smoking was a significant predictor for progression of calcification in the multivariate analysis (OR, 6.051 in less than 1 pack per day smokers; OR, 36.562 in more than 1 pack per day smokers; p=0.008). Continued smoking accelerates pancreatic calcification, and the amount of smoking is associated with the progression of calcification in chronic pancreatitis.
Bagrosky, Brian M; Hayes, Kari L; Koo, Phillip J; Fenton, Laura Z
2013-08-01
Evaluation of the child with spinal fusion hardware and concern for infection is challenging because of hardware artifact with standard imaging (CT and MRI) and difficult physical examination. Studies using (18)F-FDG PET/CT combine the benefit of functional imaging with anatomical localization. To discuss a case series of children and young adults with spinal fusion hardware and clinical concern for hardware infection. These people underwent FDG PET/CT imaging to determine the site of infection. We performed a retrospective review of whole-body FDG PET/CT scans at a tertiary children's hospital from December 2009 to January 2012 in children and young adults with spinal hardware and suspected hardware infection. The PET/CT scan findings were correlated with pertinent clinical information including laboratory values of inflammatory markers, postoperative notes and pathology results to evaluate the diagnostic accuracy of FDG PET/CT. An exempt status for this retrospective review was approved by the Institution Review Board. Twenty-five FDG PET/CT scans were performed in 20 patients. Spinal fusion hardware infection was confirmed surgically and pathologically in six patients. The most common FDG PET/CT finding in patients with hardware infection was increased FDG uptake in the soft tissue and bone immediately adjacent to the posterior spinal fusion rods at multiple contiguous vertebral levels. Noninfectious hardware complications were diagnosed in ten patients and proved surgically in four. Alternative sources of infection were diagnosed by FDG PET/CT in seven patients (five with pneumonia, one with pyonephrosis and one with superficial wound infections). FDG PET/CT is helpful in evaluation of children and young adults with concern for spinal hardware infection. Noninfectious hardware complications and alternative sources of infection, including pneumonia and pyonephrosis, can be diagnosed. FDG PET/CT should be the first-line cross-sectional imaging study in patients with suspected spinal hardware infection. Because pneumonia was diagnosed as often as spinal hardware infection, initial chest radiography should also be performed.
Positron Emission Tomography/Computed Tomography in the Staging and Treatment of Anal Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sveistrup, Joen, E-mail: joensveistrup@hotmail.com; Loft, Annika; Berthelsen, Anne Kiil
2012-05-01
Purpose: This study was intended to determine the role of PET/CT in the staging of anal cancer as a supplement to three-dimensional transanal ultrasound (TAUS) and inguinal ultrasound (US). The impact of the PET/CT on the initial stage and treatment plan proposed by TAUS/US was assessed. Methods and Materials: Ninety-five (95) patients referred to our clinic between July 1, 2005, and December 31, 2009, were retrospectively reviewed. All patients had biopsy-proven primary squamous cell cancer of the anal canal. There were 65 females (68%) and 30 males (32%), and the median age was 58 years (range, 35-88 years). Six (6%)more » of the patients were HIV positive. All patients were staged with TAUS/US and PET/CT. Results: Twenty-eight (28) patients were diagnosed with suspicious perirectal node metastases. TAUS visualized 24 of these, whereas PET/CT detected 15. Suspicious inguinal nodes were visualized on either US or PET/CT in 41 patients. Seventeen (17) of these had confirmed malignant disease on biopsy, and 15 had confirmed benign disease. All 17 patients (100%) with malignant inguinal nodes were diagnosed by PET/CT, whereas US identified 16 (94%). Ten patients were diagnosed with suspicious inguinal nodes on PET/CT that had not been seen on US. One of these was malignant, three were benign, and six were not biopsied. PET/CT diagnosed eight metastatic sites, whereas TAUS/US diagnosed three. PET/CT discovered three of the five synchronous cancers seen in this study. PET/CT upstaged the disease in 14% of the cases and changed the treatment plan proposed by TAUS/US in 17%. Conclusion: PET/CT has great potential influence on the staging and treatment of anal cancer. TAUS is important in the staging of the primary tumor and N1-stage, whereas PET/CT seems necessary for the N2/3-stage, the M-stage and synchronous cancers.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stützer, Kristin; Haase, Robert; Exner, Florian
2016-09-15
Purpose: Rating both a lung segmentation algorithm and a deformable image registration (DIR) algorithm for subsequent lung computed tomography (CT) images by different evaluation techniques. Furthermore, investigating the relative performance and the correlation of the different evaluation techniques to address their potential value in a clinical setting. Methods: Two to seven subsequent CT images (69 in total) of 15 lung cancer patients were acquired prior, during, and after radiochemotherapy. Automated lung segmentations were compared to manually adapted contours. DIR between the first and all following CT images was performed with a fast algorithm specialized for lung tissue registration, requiring themore » lung segmentation as input. DIR results were evaluated based on landmark distances, lung contour metrics, and vector field inconsistencies in different subvolumes defined by eroding the lung contour. Correlations between the results from the three methods were evaluated. Results: Automated lung contour segmentation was satisfactory in 18 cases (26%), failed in 6 cases (9%), and required manual correction in 45 cases (66%). Initial and corrected contours had large overlap but showed strong local deviations. Landmark-based DIR evaluation revealed high accuracy compared to CT resolution with an average error of 2.9 mm. Contour metrics of deformed contours were largely satisfactory. The median vector length of inconsistency vector fields was 0.9 mm in the lung volume and slightly smaller for the eroded volumes. There was no clear correlation between the three evaluation approaches. Conclusions: Automatic lung segmentation remains challenging but can assist the manual delineation process. Proven by three techniques, the inspected DIR algorithm delivers reliable results for the lung CT data sets acquired at different time points. Clinical application of DIR demands a fast DIR evaluation to identify unacceptable results, for instance, by combining different automated DIR evaluation methods.« less
Hanyok, Brian T; Howard, Lauren E; Amling, Christopher L; Aronson, William J; Cooperberg, Matthew R; Kane, Christopher J; Terris, Martha K; Posadas, Edwin M; Freedland, Stephen J
2016-01-15
Metastatic lesions in prostate cancer beyond the bone have prognostic importance and affect clinical therapeutic decisions. Few data exist regarding the prevalence of soft-tissue metastases at the initial diagnosis of metastatic castration-resistant prostate cancer (mCRPC). This study analyzed 232 men with nonmetastatic (M0) castration-resistant prostate cancer (CRPC) who developed metastases detected by a bone scan or computed tomography (CT). All bone scans and CT scans within the 30 days before or after the mCRPC diagnosis were reviewed. The rate of soft-tissue metastases among those undergoing CT was determined. Then, predictors of soft-tissue metastases and visceral and lymph node metastases were identified. Compared with men undergoing CT (n = 118), men undergoing only bone scans (n = 114) were more likely to have received primary treatment (P = .048), were older (P = .013), and less recently developed metastases (P = .018). Among those undergoing CT, 52 (44%) had soft-tissue metastases, including 20 visceral metastases (17%) and 41 lymph node metastases (35%), whereas 30% had no bone involvement. In a univariable analysis, only prostate-specific antigen (PSA) predicted soft-tissue metastases (odds ratio [OR], 1.27; P = .047), and no statistically significant predictors of visceral metastases were found. A higher PSA level was associated with an increased risk of lymph node metastases (OR, 1.38; P = .014), whereas receiving primary treatment was associated with decreased risk (OR, 0.36; P = .015). The data suggest that there is a relatively high rate of soft-tissue metastasis (44%) among CRPC patients undergoing CT at the initial diagnosis of metastases, including some men with no bone involvement. Therefore, forgoing CT during a metastatic evaluation may lead to an underdiagnosis of soft-tissue metastases and an underdiagnosis of metastases in general. Cancer 2015. © 2015 American Cancer Society. Cancer 2016;122:222-229. © 2015 American Cancer Society. © 2015 American Cancer Society.
Frostbite: Spectrum of Imaging Findings and Guidelines for Management
Brown, Richard K. J.; Levi, Benjamin; Kraft, Casey T.; Jacobson, Jon A.; Gross, Milton D.; Wong, Ka Kit
2016-01-01
Frostbite is a localized cold thermal injury that results from tissue freezing. Frostbite injuries can have a substantial effect on long-term limb function and mobility if not promptly evaluated and treated. Imaging plays a critical role in initial evaluation of frostbite injuries and in monitoring response to treatment. A multimodality approach involving radiography, digital subtraction angiography (DSA), and/or multiphase bone scintigraphy with hybrid single photon emission computed tomography (SPECT)/computed tomography (CT) is often necessary for optimal guidance of frostbite care. Radiographs serve as an initial survey of the affected limb and may demonstrate characteristic findings, depending on the time course and severity of injury. DSA is used to evaluate perfusion of affected soft tissues and identify potential targets for therapeutic intervention. Angiography-directed thrombolysis plays an essential role in tissue preservation and salvage in deep frostbite injuries. Multiphase bone scintigraphy with technetium 99m–labeled diphosphonate provides valuable information regarding the status of tissue viability after initial treatment. The addition of SPECT/CT to multiphase bone scintigraphy enables precise anatomic localization of the level and depth of tissue necrosis before its appearance at physical examination and can help uncover subtle findings that may remain occult at scintigraphy alone. Multiphase bone scintigraphy with SPECT/CT is the modality of choice for prognostication and planning of definitive surgical care of affected limbs. Appropriate use of imaging to direct frostbite care can help limit the effects that these injuries have on limb function and mobility. ©RSNA, 2016 PMID:27494386
How to use PET/CT in the evaluation of response to radiotherapy.
Decazes, Pierre; Thureau, Sébastien; Dubray, Bernard; Vera, Pierre
2018-06-01
Radiotherapy is a major treatment modality for many cancers. Tumor response after radiotherapy determines the subsequent steps of the patient's management (surveillance, adjuvant or salvage treatment and palliative care). Tumor response assessed during radiotherapy offers a promising opportunity to adapt the treatment plan to reduced or increased target volume, to specifically target sub-volumes with relevant biological characteristics (metabolism, hypoxia, proliferation, etc.) and to further spare the organs at risk. In addition to its role in the diagnosis and the initial staging, Positron Emission Tomography combined with a Computed Tomography (PET/CT) provides functional information and is therefore attractive to evaluate tumor response. The aim of this paper is to review the published data addressing PET/CT as an evaluation tool in irradiated tumors. Reports on PET/CT acquired at various times (during radiotherapy, after initial (chemo-) radiotherapy, after definitive radiotherapy and during posttreatment follow-up) in solid tumors (lung, head-and-neck, cervix, esophagus, prostate and rectum) were collected and reviewed. Various tracers and technical aspects are also discussed. 18F-FDG PET/CT has a well-established role in clinical routine after definitive chemo-radiotherapy for locally advanced head-and-neck cancers. 18F-choline PET/CT is indicated in prostate cancer patients with biochemical failure. 18F-FDG PET/CT is optional in many other circumstances and the clinical benefits of assessing tumor response with PET/CT remain a field of very active research. The combination of PET with Magnetic Resonance Imaging (PET/MRI) may prove to be valuable in irradiated rectal and cervix cancers. Tumor response can be evaluated by PET/CT with clinical consequences in multiple situations, notably in head and neck and prostate cancers, after radiotherapy. Further clinical evaluation for most cancers is still needed, possibly in association to MRI.
Lin, Abraham; Harris, Mitchell; Zalis, Michael
2010-07-01
Electronic medical record (EMR) systems permit integration of contextual nonimaging EMR data into examination interpretation; however, the extra effort required to search and review these nonradiologic data are not well characterized. We assessed the gross frequency and pattern of EMR usage in the interpretation of diagnostic CT and MRI examinations. We defined nonradiologic EMR data as laboratory data, nonimaging specialty report, clinical note, and administrative data not available on PACS. For abdominal, neuroradiologic, and musculoskeletal CT and MRI, we prospectively recorded the time required for image analysis (including prior imaging studies and their reports), nonradiologic EMR use, and initial report drafting by fellows and staff in randomized sessions. We assessed EMR use as a fraction of work activity and according to technique, subspecialty, inpatient status, and radiologist experience. We observed 372 CT and MRI interpretations by 33 radiologists. For CT, radiologists used the EMR in 34% of abdominal, 57% of neuroradiologic, and 38% of musculoskeletal interpretations. For MRI, EMR was used in 73% of abdominal, 56% of neuroradiologic, and 33% of musculoskeletal interpretations. For CT, EMR usage comprised 18%, 14%, and 18% of diagnostic effort (image analysis plus EMR use) for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively; for MRI, EMR usage comprised 21%, 16%, and 15% of diagnostic effort for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively. Frequency of EMR use was significantly greater for neuroradiology CT and abdominal MRI (p < 0.05, Fisher's test). EMR usage was not consistently related to inpatient status for CT or radiologist experience. For CT and MRI interpretation, EMR usage is frequent and comprises a significant fraction of diagnostic effort.
Iagaru, Andrei; Mittra, Erik; Minamimoto, Ryogo; Jamali, Mehran; Levin, Craig; Quon, Andrew; Gold, Garry; Herfkens, Robert; Vasanawala, Shreyas; Gambhir, Sanjiv Sam; Zaharchuk, Greg
2015-01-01
The recent introduction of hybrid PET/MRI scanners in clinical practice has shown promising initial results for several clinical scenarios. However, the first generation of combined PET/MRI lacks time-of-flight (TOF) technology. Here we report the results of the first patients to be scanned on a completely novel fully integrated PET/MRI scanner with TOF. We analyzed data from patients who underwent a clinically indicated F FDG PET/CT, followed by PET/MRI. Maximum standardized uptake values (SUVmax) were measured from F FDG PET/MRI and F FDG PET/CT for lesions, cerebellum, salivary glands, lungs, aortic arch, liver, spleen, skeletal muscle, and fat. Two experienced radiologists independently reviewed the MR data for image quality. Thirty-six patients (19 men, 17 women, mean [±standard deviation] age of 61 ± 14 years [range: 27-86 years]) with a total of 69 discrete lesions met the inclusion criteria. PET/CT images were acquired at a mean (±standard deviation) of 74 ± 14 minutes (range: 49-100 minutes) after injection of 10 ± 1 mCi (range: 8-12 mCi) of F FDG. PET/MRI scans started at 161 ± 29 minutes (range: 117 - 286 minutes) after the F FDG injection. All lesions identified on PET from PET/CT were also seen on PET from PET/MRI. The mean SUVmax values were higher from PET/MRI than PET/CT for all lesions. No degradation of MR image quality was observed. The data obtained so far using this investigational PET/MR system have shown that the TOF PET system is capable of excellent performance during simultaneous PET/MR with routine pulse sequences. MR imaging was not compromised. Comparison of the PET images from PET/CT and PET/MRI show no loss of image quality for the latter. These results support further investigation of this novel fully integrated TOF PET/MRI instrument.
NASA Astrophysics Data System (ADS)
Rudolph, Tobias; Ebert, Lars; Kowal, Jens
2006-03-01
Supporting surgeons in performing minimally invasive surgeries can be considered as one of the major goals of computer assisted surgery. Excellent intraoperative visualization is a prerequisite to achieve this aim. The Siremobil Iso-C 3D has become a widely used imaging device, which, in combination with a navigation system, enables the surgeon to directly navigate within the acquired 3D image volume without any extra registration steps. However, the image quality is rather low compared to a CT scan and the volume size (approx. 12 cm 3) limits its application. A regularly used alternative in computer assisted orthopedic surgery is to use of a preoperatively acquired CT scan to visualize the operating field. But, the additional registration step, necessary in order to use CT stacks for navigation is quite invasive. Therefore the objective of this work is to develop a noninvasive registration technique. In this article a solution is being proposed that registers a preoperatively acquired CT scan to the intraoperatively acquired Iso-C 3D image volume, thereby registering the CT to the tracked anatomy. The procedure aligns both image volumes by maximizing the mutual information, an algorithm that has already been applied to similar registration problems and demonstrated good results. Furthermore the accuracy of such a registration method was investigated in a clinical setup, integrating a navigated Iso-C 3D in combination with an tracking system. Initial tests based on cadaveric animal bone resulted in an accuracy ranging from 0.63mm to 1.55mm mean error.
NASA Astrophysics Data System (ADS)
Raylman, Raymond R.; Stolin, Alexander V.; Sompalli, Prashanth; Randall, Nicole Bunda; Martone, Peter F.; Clinthorne, Neal H.
2015-10-01
Staging of head and neck cancer (HNC) is often hindered by the limited resolution of standard whole body PET scanners, which can make it challenging to detect small areas of metastatic disease in regional lymph nodes and accurately delineate tumor boundaries. In this investigation, the performance of a proposed high resolution PET/CT scanner designed specifically for imaging of the head and neck region was explored. The goal is to create a dedicated PET/CT system that will enhance the staging and treatment of HNCs. Its performance was assessed by simulating the scanning of a three-dimensional Rose-Burger contrast phantom. To extend the results from the simulation studies, an existing scanner with a similar geometry to the dedicated system and a whole body, clinical PET/CT scanner were used to image a Rose-Burger contrast phantom and a phantom simulating the neck of an HNC patient (out-of-field-of-view sources of activity were not included). Images of the contrast detail phantom acquired with Breast-PET/CT and simulated head and neck scanner both produced object contrasts larger than the images created by the clinical scanner. Images of a neck phantom acquired with the Breast-PET/CT scanner permitted the identification of all of the simulated metastases, while it was not possible to identify any of the simulated metastasis with the clinical scanner. The initial results from this study demonstrate the potential benefits of high-resolution PET systems for improving the diagnosis and treatment of HNC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, X; Dormer, J; Kenton, O
Purpose: Plan robustness of the passive-scattering proton therapy treatment of lung tumors has been studied previously using combined uncertainties of 3.5% in CT number and 3 mm geometric shifts. In this study, we investigate whether this method is sufficient to predict proton plan robustness by comparing to plans performed on weekly verification CT scans. Methods: Ten lung cancer patients treated with passive-scattering proton therapy were randomly selected. All plans were prescribed 6660cGy in 37 fractions. Each initial plan was calculated using +/− 3.5% range and +/− 0.3cm setup uncertainty in x, y and z directions in Eclipse TPS(Method-A). Throughout themore » treatment course, patients received weekly verification CT scans to assess the daily treatment variation(Method-B). After contours and imaging registrations are verified by the physician, the initial plan with the same beamline and compensator was mapped into the verification CT. Dose volume histograms (DVH) were evaluated for robustness study. Results: Differences are observed between method A and B in terms of iCTV coverage and lung dose. Method-A shows all the iCTV D95 are within +/− 1% difference, while 20% of cases fall outside +/−1% range in Method-B. In the worst case scenario(WCS), the iCTV D95 is reduced by 2.5%. All lung V5 and V20 are within +/−5% in Method-A while 15% of V5 and 10% of V20 fall outside of +/−5% in Method-B. In the WCS, Lung V5 increased by 15% and V20 increased by 9%. Method A and B show good agreement with regard to cord maximum and Esophagus mean dose. Conclusion: This study suggests that using range and setup uncertainty calculation (+/−3.5% and +/−3mm) may not be sufficient to predict the WCS. In the absence of regular verification scans, expanding the conventional uncertainty parameters(e.g., to +/−3.5% and +/−4mm) may be needed to better reflect plan actual robustness.« less
Dekeyzer, S; Moerman, F; Callens, S; Vandekerckhove, L
2013-01-01
Metastatic tuberculous abcess or tuberculous gumma is a rare form of cutaneous tuberculosis resulting from haematogenous spread from a non-cutaneous tuberculous focus. A 26-year old patient of Pakistani origin presented at our clinic with an abcess on his right thigh that had slowly grown over a period of two months to a total size of 30 cm. Based on clinical findings, microbiology, CT thigh and CT chest, our patient was diagnosed with a tuberculous abcess and cervico-mediastinal tuberculous lymphadenitis. Antituberculosis drugs were initiated. Cutaneous tuberculosis should be included in the differential diagnosis of chronic cutaneous abcesses, especially in patients from tuberculosis endemic nations.
Quantitative CT Evaluation of Small Pulmonary Vessels in Patients with Acute Pulmonary Embolism.
Matsuoka, Shin; Kotoku, Akiyuki; Yamashiro, Tsuneo; Matsushita, Shoichiro; Fujikawa, Atsuko; Yagihashi, Kunihiro; Nakajima, Yasuo
2018-05-01
The objective of this study was to investigate the correlation between the computed tomography (CT) cross-sectional area (CSA) of small pulmonary vessels and the CT obstruction index in patients with acute pulmonary embolism (PE) and the correlation between the changes in these measurements after anticoagulant therapy. Fifty-two patients with acute PE were selected for this study. We measured the CSA less than 5 mm 2 on coronal reconstructed images to obtain the percentage of the CSA (%CSA < 5). CT angiographic index was obtained based on the Qanadli method for the evaluation of the degree of pulmonary arterial obstruction. Spearman rank correlation analysis was used to evaluate the relationship between the initial and the follow-up values and changes in the %CSA < 5 and the CT obstruction index. There was no significant correlation between the %CSA < 5 and CT obstruction index on both initial (ρ = -0.03, P = 0.84) and follow-up (ρ = -0.03, P = 0.82) assessments. In contrast, there was a significant negative correlation between the changes in %CSA < 5 and the CT obstruction index (ρ = -0.59, P < 0.0001). Although the absolute %CSA < 5 and CT obstruction index were not significantly correlated, the changes in the values of the two parameters had a significant correlation. Changes in %CSA < 5, which can be obtained easily, can be used as biomarker of therapeutic response in patients with acute PE. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Juang, T; Bush, K; Loo, B
Purpose: We propose a workflow to improve access to stereotactic ablative radiation therapy (SABR) for rural patients. When implemented, a separate trip to the central facility for simulation can be eliminated. Two elements are required: (1) Fabrication of custom immobilization devices to match positioning on prior diagnostic CT (dxCT). (2) Remote radiation pre-planning on dxCT, with transfer of contours/plan to simulation CT (simCT) and initiation of treatment same-day or next day. In this retrospective study, we validated part 2 of the workflow using patients already treated with SABR for upper lobe lung tumors. Methods: Target/normal structures were contoured on dxCT;more » a plan was created and approved by the physician. Structures were transferred to simCT using deformable image registration and the plan was re-optimized on simCT. Plan quality was evaluated through comparison to gold-standard structures contoured on simCT and a gold-standard plan based on these structures. Workflow-generated plan quality in this study represents a worst-case scenario as these patients were not treated using custom immobilization to match dxCT position as would be done when the workflow is implemented clinically. Results: 5/6 plans created through the pre-planning workflow were clinically acceptable. For all six plans, the gold-standard GTV received full prescription dose, along with median PTV V95%=95.2% and median PTV D95%=95.4%. Median GTV DSC=0.80, indicating high degree of similarity between the deformed and gold-standard GTV contours despite small GTV sizes (mean=3.0cc). One outlier (DSC=0.49) resulted in inadequate PTV coverage (V95%=62.9%) in the workflow plan; in clinical practice, this mismatch between deformed/gold-standard GTV would be revised by the physician after deformable registration. For all patients, normal tissue doses were comparable to the gold-standard plan and well within constraints. Conclusion: Pre-planning SABR cases on diagnostic imaging generated clinically acceptable plans. Coupled with rapid-prototyped custom immobilization, this workflow may improve treatment access for rural patients.« less
Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun
2017-01-01
Background: Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Methods: Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images <60 keV in Group A. The total radiation dose, total iodine load, contrast injection speed, and maximum injection pressure were compared between the two groups. The 40 keV and 60 keV spectral CT images of Group A were compared with the images of Group B to evaluate overall image quality. Results: The total radiation dose, total iodine load, injection speed, and maximum injection pressure for Group A were decreased by 19%, 15%, 34.4%, and 18.3%, respectively. The optimal energy level in spectral CT for displaying the abdominal vessels was 40 keV. At this level, the CT values in the abdominal aorta and its three branches, the portal vein and its two branches, and the inferior vena cava were all greater than 340 hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and −1.716 for liver, −0.153 and −1.546 for pancreas, and 2.427 and 0.866 for renal cortex, all P > 0.05). Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t = −8.11 for liver, −7.83 for pancreas, and −5.38 for renal cortex, all P < 0.05). However, the subjective scores for the 40 keV (FBP) and 60 keV (40% ASiR) spectral CT images determined by two radiologists were all >3, indicating clinically acceptable image quality. Conclusions: Single-phase, dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality. PMID:28345547
Interpretation of Brain CT Scans in the Field by Critical Care Physicians in a Mobile Stroke Unit
Zakariassen, Erik; Lindner, Thomas; Nome, Terje; Bache, Kristi G.; Røislien, Jo; Gleditsch, Jostein; Solyga, Volker; Russell, David; Lund, Christian G.
2017-01-01
ABSTRACT BACKGROUND AND PURPOSE In acute stroke, thromboembolism or spontaneous hemorrhage abruptly reduces blood flow to a part of the brain. To limit necrosis, rapid radiological identification of the pathological mechanism must be conducted to allow the initiation of targeted treatment. The aim of the Norwegian Acute Stroke Prehospital Project is to determine if anesthesiologists, trained in prehospital critical care, may accurately assess cerebral computed tomography (CT) scans in a mobile stroke unit (MSU). METHODS In this pilot study, 13 anesthesiologists assessed unselected acute stroke patients with a cerebral CT scan in an MSU. The scans were simultaneously available by teleradiology at the receiving hospital and the on‐call radiologist. CT scan interpretation was focused on the radiological diagnosis of acute stroke and contraindications for thrombolysis. The aim of this study was to find inter‐rater agreement between the pre‐ and in‐hospital radiological assessments. A neuroradiologist evaluated all CT scans retrospectively. Statistical analysis of inter‐rater agreement was analyzed with Cohen's kappa. RESULTS Fifty‐one cerebral CT scans from the MSU were included. Inter‐rater agreement between prehospital anesthesiologists and the in‐hospital on‐call radiologists was excellent in finding radiological selection for thrombolysis (kappa .87). Prehospital CT scans were conducted in median 10 minutes (7 and 14 minutes) in the MSU, and median 39 minutes (31 and 48 minutes) before arrival at the receiving hospital. CONCLUSION This pilot study shows that anesthesiologists trained in prehospital critical care may effectively assess cerebral CT scans in an MSU, and determine if there are radiological contraindications for thrombolysis. PMID:28766306
New trends in the cyber and street market of recreational drugs? The case of 2C-T-7 ('Blue Mystic').
Schifano, Fabrizio; Deluca, Paolo; Agosti, Lisa; Martinotti, Giovanni; Corkery, John M; Alex, Baldacchino; Caterina, Bonan; Heikki, Bothas; Raffaella, Brigada; Anna, Comacchio; Lucia, Di Furia; Dorte, Duarte Rui Eastwood; Magi, Farré; Susana, Ferreira; Irene, Flores; Claude, Guionnet; Lisbet, Harder; Lene, Stokholm Jensen; Mauro, Leoni; Christopher, Littlejohn; Aino, Majava; Teuvo, Peltoniemi; Milena, Pizza; Salman, Rawaf; Damien, Robert; Angela, Rossi Maria; Francesco, Rovetto; Norbert, Scherbaum; Holger, Siemann; Josep, Tarrago; Marta, Torrens; Francesco, Zambello
2005-11-01
2C-T-7 ('Blue Mystic'), an illicit compound which shows similarities with MDMA and other designer drugs, has been only occasionally identified in the EU, but discussion on the Internet between experimenters has recently grown significantly. We aimed at collecting together in a review the available information on 2C-T-7, both at the cyber and at the street market level. 2C-T-7 was first synthesized in 1986; its desired effects include both a sense of empathy and of well-being. Hallucinations, nausea, anxiety, panic attacks and paranoid ideation are anecdotally reported. According to the different European sources here approached, the availability of 2C-T-7 at street level seems to be currently very low, although one death related to a mono-intoxication with 2C-T-7 has been documented in the USA. With respect to information on 2C-T-7 available online, due to both redundancy and relevance issues the initial identified sample of 360 was reduced to 118 websites. In 14 (11.9%) websites, the detailed description of the 2C-T-7 synthesis was given. Harm Reduction websites appeared significantly earlier in the search engines results' list than Anti drugs (p 0.006) websites. Five (4.2%) websites apparently offered 2C-T-7 for sale. The large body of knowledge available online seems to contrast with small numbers of seizures at street level; an exhaustive web mapping of drug-related issues may be of interest for the clinician. Projects aimed at designing more 'attractive' prevention websites should be planned and future studies should better assess the characteristics of those consumers who take advantage of the online information of hallucinogenic compounds.
Craver, Chris; Gayle, Julie; Balu, Sanjeev; Buchner, Deborah
2011-01-01
This study evaluated the rate of uncontrolled chemotherapy-induced nausea and vomiting (CINV) after initiating antiemetic prophylaxis with palonosetron versus other 5-HT₃ receptor antagonists (RAs) in patients diagnosed with hematologic malignancies (lymphoma and leukemia) and receiving highly emetogenic chemotherapy (HEC) or moderately emetogenic chemotherapy (MEC) in a hospital outpatient setting. Patients aged ≥ 18 years and diagnosed with hematologic malignancies initiating HEC or MEC and antiemetic prophylaxis with palonosetron (Group 1) and other 5-HT₃ RAs (Group 2) for the first time in a hospital outpatient setting between 4/1/2007 and 3/31/2009 were identified from the Premier Perspective Database. Within each cycle, CINV events were identified (in the hospital outpatient, inpatient, and emergency room settings) through ICD-9 codes for nausea, vomiting, and/or volume depletion (from each CT administration day 1 until the end of the CT cycle), or use of rescue medications (day 2 until the end of the CT cycle). Negative binomial distribution generalized linear multivariate regression model estimating the CINV event rate on CT, specific CT cycles, and cancer diagnosis (leukemia/lymphoma)-matched groups in the follow-up period (first of 8 cycles or 6 months) was developed. Of 971 identified patients, 211 initiated palonosetron (Group 1). Group 1 patients comprised of more females [50.2 vs. 41.4%; p = 0.0226], Whites [74.4 vs. 70.4%, and Hispanics [7.6 vs. 6.3%; all races p = 0.0105], received more HEC treatments [89.6 vs. 84.2%; all CT types p = 0.0129], and had more lymphoma diagnosed patients [89.6 vs. 76.3%; all cancer types p = 0.0033] at baseline. After controlling for differences in several demographic and clinical variables, the regression model predicted a 20.4% decrease in CINV event rate per CT cycle for Group 1 versus Group 2 patients. Study limitations include potential lack of generalizability, absence of data on certain confounders including alcohol consumption and prior history of motion sickness, potential underestimation of incidence of uncontrolled CINV, and inability to draw conclusions pertaining to cause and effect relationship. In this retrospective hospital study, patients with hematologic malignancies treated with HEC or MEC and initiated on antiemetic prophylaxis with palonosetron in the hospital outpatient setting were more likely to experience significantly lower CINV event rates (in the hospital outpatient, inpatient, and emergency room settings) versus patients initiated on other 5-HT₃ RAs.
SU-E-T-217: Intrinsic Respiratory Gating in Small Animal CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Y; Smith, M; Mistry, N
Purpose: Preclinical animal models of lung cancer can provide a controlled test-bed for testing dose escalation or function-based-treatment-planning studies. However, to extract lung function, i.e. ventilation, one needs to be able to image the lung at different phases of ventilation (in-hale / ex-hale). Most respiratory-gated imaging using micro-CT involves using an external ventilator and surgical intervention limiting the utility in longitudinal studies. A new intrinsic respiratory retrospective gating method was developed and tested in mice. Methods: A fixed region of interest (ROI) that covers the diaphragm was selected on all projection images to estimate the mean intensity (M). The meanmore » intensity depends on the projection angle and diaphragm position. A 3-point moving average (A) of consecutive M values: Mpre, Mcurrent and Mpost, was calculated to be subtracted from Mcurrent. A fixed threshold was used to enable amplitude based sorting into 4 different phases of respiration. Images at full-inhale and end-exhale phases of respiration were reconstructed using the open source OSCaR. Lung volumes estimated at the 2 phases of respiration were validated against literature values. Results: Intrinsic retrospective gating was accomplished without the use of any external breathing waveform. While projection images were acquired at 360 different angles. Only 138 and 104 projections were used to reconstruct images at full-inhale and end-exhale. This often results in non-uniform under-sampled angular projections leading to some minor streaking artifacts. The calculated expiratory, inspiratory and tidal lung volumes correlated well with the values known from the literature. Conclusion: Our initial result demonstrates an intrinsic gating method that is suitable for flat panel cone beam small animal CT systems. Reduction in streaking artifacts can be accomplished by oversampling the data or using iterative reconstruction methods. This initial experience will enable freebreathing small animal micro-CT imaging to fuel longitudinal studies of lung function.« less
A CT-based Simulator for Hardwood Log Veneering
Daniel L. Schmoldt; Pei Li; Philip A. Araman
1995-01-01
Profits for hardwood veneer manufacturers are dependent on proper initial log breakdown (flitching) decisions. While human skill is often adequate to ãreadä bark indicators of internal defects, it is much more difficult to envision potential veneer patterns that result from different flitching options. Different veneer patterns greatly affect potential markets and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balik, M; Rybak, M; Strongosky, M
2015-06-15
Purpose: This study investigates whether replanning each fraction for vaginal cuff HDR therapy using a multichannel cylinder (MC) and brachytherapy inverse optimization (BIO) provides dosimetric benefits to organs-at-risk (OAR). The goal was to appropriately cover the target and limit dose to OAR, as well as evaluate dosimetric changes for each fraction, while doing this in a timely and cost effective manner. Methods: From an initial selection of 57 patients that were treated with 3 fractions using a MC and BIO, a subset of n=12 patients was selected based on the criterion that one plan was used for all 3 fractions.more » A simulation CT was acquired prior to each fraction. CT scans for fractions 2 and 3 were fused to the initial CT. Contours for the bladder and rectum were manually drawn on CTs for all 3 fractions, and the clinical treatment volume (PTVeval) was defined. Cylinders were reconstructed using applicator modeling library, influencing time and cost effectiveness. Planning objectives were at least 95% prescription dose to 95% (D95%) of target volume and limiting high dose to OAR. Dose to 2 cm{sup 3} (D2cc) for each OAR was analyzed using a t-test. Results: This study concentrated on comparing 2cm{sup 3} of highest dose to OAR (D2cc), for each fraction for the plans that were used to treat all 3 fraction. Based on statistical analysis, using the initial plan for fractions 2 and 3 resulted in approximately 6% change to the highest D2cc of the bladder (p=0.03). Conclusion: Performing CT fusion and contours of each OAR on each fraction allows objective plan evaluation and supports decision making on the necessity of replanning based on improved dose sparing for OAR. Future studies will investigate the effects of replanning on maximum dose (D0.1cc) using the same physician-drawn OAR contours to avoid subjectivity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veiga, Catarina; Janssens, Guillaume; Teng, Ching-Ling
2016-05-01
Purpose: An adaptive proton therapy workflow using cone beam computed tomography (CBCT) is proposed. It consists of an online evaluation of a fast range-corrected dose distribution based on a virtual CT (vCT) scan. This can be followed by more accurate offline dose recalculation on the vCT scan, which can trigger a rescan CT (rCT) for replanning. Methods and Materials: The workflow was tested retrospectively for 20 consecutive lung cancer patients. A diffeomorphic Morphon algorithm was used to generate the lung vCT by deforming the average planning CT onto the CBCT scan. An additional correction step was applied to account formore » anatomic modifications that cannot be modeled by deformation alone. A set of clinical indicators for replanning were generated according to the water equivalent thickness (WET) and dose statistics and compared with those obtained on the rCT scan. The fast dose approximation consisted of warping the initial planned dose onto the vCT scan according to the changes in WET. The potential under- and over-ranges were assessed as a variation in WET at the target's distal surface. Results: The range-corrected dose from the vCT scan reproduced clinical indicators similar to those of the rCT scan. The workflow performed well under different clinical scenarios, including atelectasis, lung reinflation, and different types of tumor response. Between the vCT and rCT scans, we found a difference in the measured 95% percentile of the over-range distribution of 3.4 ± 2.7 mm. The limitations of the technique consisted of inherent uncertainties in deformable registration and the drawbacks of CBCT imaging. The correction step was adequate when gross errors occurred but could not recover subtle anatomic or density changes in tumors with complex topology. Conclusions: A proton therapy workflow based on CBCT provided clinical indicators similar to those using rCT for patients with lung cancer with considerable anatomic changes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Deok Hee; Hwang, Jae Cheol; Lim, Soo Mee
Purpose: To describe the findings of pleural and pulmonary staining of the inferior phrenic artery, which can be confused with tumor staining during transarterial chemoembolization (TACE) of hepatoma.Methods: Fifteen patients who showed pleural and pulmonary staining without relationship to hepatic masses at inferior phrenic arteriography were enrolled. The staining was noted at initial TACE (n = 8), at successive TACE (n = 5), and after hepatic surgery (n = 2). The angiographic pattern, the presence of pleural change on computed tomography (CT), and clinical history were evaluated.Results: Draining pulmonary veins were seen in all cases. The lower margin of themore » staining corresponded to the lower margin of the pleura in 10 patients. CT showed pleural and/or pulmonary abnormalities in all cases. After embolization of the inferior phrenic artery, the accumulation of iodized oil in the lung was noted.Conclusion: Understanding the CT and angiographic findings of pleural and pulmonary staining during TACE may help differentiate benign staining from tumor staining.« less
Dictionary learning-based CT detection of pulmonary nodules
NASA Astrophysics Data System (ADS)
Wu, Panpan; Xia, Kewen; Zhang, Yanbo; Qian, Xiaohua; Wang, Ge; Yu, Hengyong
2016-10-01
Segmentation of lung features is one of the most important steps for computer-aided detection (CAD) of pulmonary nodules with computed tomography (CT). However, irregular shapes, complicated anatomical background and poor pulmonary nodule contrast make CAD a very challenging problem. Here, we propose a novel scheme for feature extraction and classification of pulmonary nodules through dictionary learning from training CT images, which does not require accurately segmented pulmonary nodules. Specifically, two classification-oriented dictionaries and one background dictionary are learnt to solve a two-category problem. In terms of the classification-oriented dictionaries, we calculate sparse coefficient matrices to extract intrinsic features for pulmonary nodule classification. The support vector machine (SVM) classifier is then designed to optimize the performance. Our proposed methodology is evaluated with the lung image database consortium and image database resource initiative (LIDC-IDRI) database, and the results demonstrate that the proposed strategy is promising.
Adaptive learning compressive tracking based on Markov location prediction
NASA Astrophysics Data System (ADS)
Zhou, Xingyu; Fu, Dongmei; Yang, Tao; Shi, Yanan
2017-03-01
Object tracking is an interdisciplinary research topic in image processing, pattern recognition, and computer vision which has theoretical and practical application value in video surveillance, virtual reality, and automatic navigation. Compressive tracking (CT) has many advantages, such as efficiency and accuracy. However, when there are object occlusion, abrupt motion and blur, similar objects, and scale changing, the CT has the problem of tracking drift. We propose the Markov object location prediction to get the initial position of the object. Then CT is used to locate the object accurately, and the classifier parameter adaptive updating strategy is given based on the confidence map. At the same time according to the object location, extract the scale features, which is able to deal with object scale variations effectively. Experimental results show that the proposed algorithm has better tracking accuracy and robustness than current advanced algorithms and achieves real-time performance.
Nesterets, Yakov I; Gureyev, Timur E; Mayo, Sheridan C; Stevenson, Andrew W; Thompson, Darren; Brown, Jeremy M C; Kitchen, Marcus J; Pavlov, Konstantin M; Lockie, Darren; Brun, Francesco; Tromba, Giuliana
2015-11-01
Results are presented of a recent experiment at the Imaging and Medical beamline of the Australian Synchrotron intended to contribute to the implementation of low-dose high-sensitivity three-dimensional mammographic phase-contrast imaging, initially at synchrotrons and subsequently in hospitals and medical imaging clinics. The effect of such imaging parameters as X-ray energy, source size, detector resolution, sample-to-detector distance, scanning and data processing strategies in the case of propagation-based phase-contrast computed tomography (CT) have been tested, quantified, evaluated and optimized using a plastic phantom simulating relevant breast-tissue characteristics. Analysis of the data collected using a Hamamatsu CMOS Flat Panel Sensor, with a pixel size of 100 µm, revealed the presence of propagation-based phase contrast and demonstrated significant improvement of the quality of phase-contrast CT imaging compared with conventional (absorption-based) CT, at medically acceptable radiation doses.
Evaluation of the effect of low tube voltage on radiation dose and image quality
NASA Astrophysics Data System (ADS)
Norhasrina Nik Din, Nik; Zainon, Rafidah; Rahman, A. T. Abdul
2017-05-01
Number of Computed Tomography (CT) examinations performed worldwide is increasing. In 2010, the FDA issued an initiative to reduce unnecessary radiation exposure from CT imaging. The aim of this study is to evaluate the effect of low tube voltage on radiation dose and image quality using CTDI phantom. The CTDI phantom was scanned with dual energy CT at 80 kV and 120 kV with the tube current from 150 mAs to 350 mAs. Pitch was 1.0 while slice thickness was 1 mm and 5 mm. Results show if mAs was increased, the SNR values also will be increased. The 5 mm slice thickness shows higher SNR value compared to 1 mm slice thickness. As the voltage and tube current increased, the amount of dose absorbed is also increased because current is proportional to photon flux.
Delayed hydronephrosis due to retroperitoneal hematoma after a seatbelt injury
Yumoto, Tetsuya; Kondo, Yoshitaka; Kumon, Kento; Masaoka, Yoshihisa; Hiraki, Takao; Yamada, Taihei; Naito, Hiromichi; Nakao, Atsunori
2018-01-01
Abstract Rationale: Hydronephrosis caused by retroperitoneal hematoma after a seatbelt injury is a unique clinical entity. Patient concerns: A 21-year-old man, who had been wearing a seatbelt, was brought to our hospital after a motor vehicle collision, complaining of abdominal pain. Computed tomography (CT) revealed retroperitoneal hematoma in the upper pelvic region. Since he was hemodynamically stable throughout admission, he was managed conservatively. Seventeen days after initial discharge, the patient revisited our emergency department due to right back pain. Diagnoses: CT scans indicated retroperitoneal hematoma growth resulting in hydronephrosis of the right kidney. Interventions: Laparoscopic drainage of the retroperitoneal hematoma was successfully performed. Outcomes: His symptoms resolved after the surgery. Follow-up CT scans three months later demonstrated complete resolution of the hydronephrosis and retroperitoneal hematoma. Lessons: Our case highlights a patient with delayed hydronephrosis because of retroperitoneal hematoma expansion after a seatbelt injury. PMID:29879068
Vadi, Shelvin Kumar; Singh, Baljinder; Basher, Rajender K; Watts, Ankit; Sood, Ashwani K; Lal, Anupam; Kakkar, Nandita; Singh, S K
2017-08-01
The aim of this study was to compare the diagnostic performance of F-fluorocholine (FCH) PET/CT and dynamic contrast-enhanced MRI (DCE-MRI) of pelvis in restaging prostate cancer (PC) patients with biochemical recurrence (BCR) following radical prostatectomy (RP). Twenty PC patients who had undergone RP and had BCR were recruited in this study. All the patients underwent whole-body FCH PET/CT and DCE-MRI of the pelvis. An overall pattern of recurrent disease was analyzed, and diagnostic accuracy for the detection of pelvic disease recurrence by the 2 modalities was evaluated by taking histopathologic analysis as the criterion standard. The whole-body FCH PET/CT images were also analyzed separately for the presence of any extra lesion(s). The initial mean Gleason score was 6.3 ± 1.53 (range, 4-9). The mean prostate-specific antigen levels at the time of relapse were 1.9 ± 2.87 ng/mL (range, 0.24-13.2 ng/mL). MRI findings were positive for primary tumor recurrence in the prostate bed in 6 patients (6/20 [30.0%]), pelvic lymph node metastases in 4 patients (4/20 [20.0%]), and for pelvic skeletal metastases in 2 patients (2/20 [10.0%]), respectively. On the other hand, FCH PET/CT results were positive in the corresponding sites in 7 (7/20 [35.0%]), 9 (9/20 [45.0%]), and 2 patients (2/20 [10.0%]), respectively. F-fluorocholine PET/CT and MRI showed comparable results in terms of sensitivity, specificity, and positive and negative predictive values for PC characterization. The whole-body FCH PET/CT was found to be useful in identifying unknown distant metastases in a significant proportion of patients. The correlative whole-body FCH PET/CT and pelvic DCE-MRI offer a complementary and comprehensive diagnostic workup for better management of PC patients with BCR following RP.
Gordic, S; Hodel, S; Simmen, H-P; Brueesch, M; Frauenfelder, T; Wanner, G; Sprengel, K
2015-01-01
Objective: To determine the number of imaging examinations, radiation dose and the time to complete trauma-related imaging in multiple trauma patients before and after introduction of whole-body CT (WBCT) into early trauma care. Methods: 120 consecutive patients before and 120 patients after introduction of WBCT into the trauma algorithm of the University Hospital Zurich were compared regarding the number and type of CT, radiography, focused assessment with sonography for trauma (FAST), additional CT examinations (defined as CT of the same body regions after radiography and/or FAST) and the time to complete trauma-related imaging. Results: In the WBCT cohort, significantly more patients underwent CT of the head, neck, chest and abdomen (p < 0.001) than in the non-WBCT cohort, whereas the number of radiographic examinations of the cervical spine, chest and pelvis and of FAST examinations were significantly lower (p < 0.001). There were no significant differences between cohorts regarding the number of radiographic examinations of the upper (p = 0.56) and lower extremities (p = 0.30). We found significantly higher effective doses in the WBCT (29.5 mSv) than in the non-WBCT cohort (15.9 mSv; p < 0.001), but fewer additional CT examinations for completing the work-up were needed in the WBCT cohort (p < 0.001). The time to complete trauma-related imaging was significantly shorter in the WBCT (12 min) than in the non-WBCT cohort (75 min; p < 0.001). Conclusion: Including WBCT in the initial work-up of trauma patients results in higher radiation doses, but fewer additional CT examinations are needed, and the time for completing trauma-related imaging is shorter. Advances in knowledge: WBCT in trauma patients is associated with a high radiation dose of 29.5 mSv. PMID:25594105
NASA Astrophysics Data System (ADS)
Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas
2012-04-01
To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between clinically acquired SPECT perfusion and specific ventilation from 4D CT. Results suggest high correlation between methods within the sub-population of lung cancer patients with malignant airway stenosis.
Pozvek, G; Hilton, J M; Quiza, M; Houssami, S; Sexton, P M
1997-04-01
The structure/function relationship of salmon calcitonin (sCT) analogues was investigated in heterologous calcitonin receptor (CTR) expression systems. sCT analogues with progressive amino-terminal truncations intermediate of sCT-(1-32) to sCT-(8-32) were examined for their ability to act as agonists, antagonists, or inverse agonists. Two CTR cell clones, B8-H10 and G12-E12, which express approximately 5 million and 25,000 C1b receptors/cell, respectively, were used for this study. The B8-H10 clone has an approximately 80-fold increase in basal levels of intracellular cAMP due to constitutive activation of the overexpressed receptor. In whole-cell competition binding studies, sCT-(1-32) was more potent than any of its amino-terminally truncated analogues in competition for 125I-sCT binding. In cAMP accumulation studies, sCT-(1-32) and modified analogues sCT-(2-32) and sCT-(3-32) had agonist activities. SDZ-216-710, with an amino-terminal truncation of four amino acids, behaved as a partial agonist/antagonist, whereas amino-terminal truncations of six or seven amino acid residues produced a 16-fold reduction in basal cAMP levels and attenuated the response to the agonist sCT-(1-32) in the constitutively active CTR system. This inverse agonist effect was insensitive to pertussis toxin inhibition. In contrast, the inverse agonist activity of these peptides was not observed in the nonconstitutively active CTR system, in which sCT analogues with amino-terminal truncations of four or more amino acids behaved as neutral competitive antagonists. These results suggest that the inverse agonist activity is mediated by stabilization of the inactive state of the receptor, which does not couple to G protein, and attenuates basal signaling initiated by ligand-independent activation of the effector adenylyl cyclase.
García, J R; Cozar, M; Soler, M; Bassa, P; Riera, E; Ferrer, J
2016-01-01
To assess the prognostic value of the therapeutic response by (11)C-choline PET/CT in prostate cancer patients with biochemical recurrence in which (11)C-choline PET/CT indicated radio-guided radiotherapy. The study included 37 patients initially treated with prostatectomy, who were treated due to biochemical recurrence. (11)C-choline PE/CT detected infra-diaphragmatic lymph-node involvement. All were selected for intensity modulated radiation therapy, escalating the dose according to the PET findings. One year after treatment patients underwent PSA and (11)C-choline PET/CT categorizing response (complete/partial/progression). Clinical/biochemical/image monitoring was performed until appearance of second relapse or 36 months in disease-free patients. (11)C-choline PET/CT could detect lymph nodes in all 37 patients. They were 18 (48.6%) of more than a centimetre in size and 19 (51.3%) with no pathological CT morphology: 9 (24.3%) with positive lymph nodes of around one centimetre and 10 (27.0%) only less than a centimetre in size. The response by (11)C-choline PET/CT was categorised one year after radiotherapy: 16 patients (43.2%) complete response; 15 (40.5%) partial response, and 6 (16.2%) progression. The response was concordant between the PSA result and (11)C-choline PET/CT in 32 patients (86.5%), and discordant in five (13.5%). New recurrence was detected in 12 patients (80%) with partial response, and 5 (31.2%) with complete response. The mean time to recurrence was 9 months after partial response, and 18 months after complete response (significant difference, p<.0001). (11)C-choline PET/CT allows the selection of patients with recurrent prostate cancer candidates for radiotherapy and to plan the technique. The evaluation of therapeutic response by (11)C-choline PET/CT has prognostic significance. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.
2D-3D registration using gradient-based MI for image guided surgery systems
NASA Astrophysics Data System (ADS)
Yim, Yeny; Chen, Xuanyi; Wakid, Mike; Bielamowicz, Steve; Hahn, James
2011-03-01
Registration of preoperative CT data to intra-operative video images is necessary not only to compare the outcome of the vocal fold after surgery with the preplanned shape but also to provide the image guidance for fusion of all imaging modalities. We propose a 2D-3D registration method using gradient-based mutual information. The 3D CT scan is aligned to 2D endoscopic images by finding the corresponding viewpoint between the real camera for endoscopic images and the virtual camera for CT scans. Even though mutual information has been successfully used to register different imaging modalities, it is difficult to robustly register the CT rendered image to the endoscopic image due to varying light patterns and shape of the vocal fold. The proposed method calculates the mutual information in the gradient images as well as original images, assigning more weight to the high gradient regions. The proposed method can emphasize the effect of vocal fold and allow a robust matching regardless of the surface illumination. To find the viewpoint with maximum mutual information, a downhill simplex method is applied in a conditional multi-resolution scheme which leads to a less-sensitive result to local maxima. To validate the registration accuracy, we evaluated the sensitivity to initial viewpoint of preoperative CT. Experimental results showed that gradient-based mutual information provided robust matching not only for two identical images with different viewpoints but also for different images acquired before and after surgery. The results also showed that conditional multi-resolution scheme led to a more accurate registration than single-resolution.
Pratter, S M; Eixelsberger, T; Nidetzky, B
2015-12-01
A novel Saccharomyces cerevisiae whole-cell biocatalyst for xylitol production based on Candida tenuis xylose reductase (CtXR) is presented. Six recombinant strains expressing wild-type CtXR or an NADH-specific mutant were constructed and evaluated regarding effects of expression mode, promoter strength, biocatalyst concentration and medium composition. Intracellular XR activities ranged from 0.09 U mgProt(-1) to 1.05 U mgProt(-1) but did not correlate with the strains' xylitol productivities, indicating that other factors limited xylose conversion in the high-activity strains. The CtXR mutant decreased the biocatalyst's performance, suggesting use of the NADPH-preferring wild-type enzyme when (semi-)aerobic conditions are applied. In a bioreactor process, the best-performing strain converted 40 g L(-1) xylose with an initial productivity of 1.16 g L(-1)h(-1) and a xylitol yield of 100%. The obtained results underline the potential of CtXR wild-type for xylose reduction and point out parameters to improve "green" xylitol production. Copyright © 2015 Elsevier Ltd. All rights reserved.
Henninger, B.; Putzer, D.; Kendler, D.; Uprimny, C.; Virgolini, I.; Gunsilius, E.; Bale, R.
2012-01-01
Aim. The purpose of this study was to evaluate the accuracy of 2-deoxy-2-[fluorine-18]fluoro-D-glucose (FDG) positron emission tomography (PET), computed tomography (CT), and software-based image fusion of both modalities in the imaging of non-Hodgkin's lymphoma (NHL) and Hodgkin's disease (HD). Methods. 77 patients with NHL (n = 58) or HD (n = 19) underwent a FDG PET scan, a contrast-enhanced CT, and a subsequent digital image fusion during initial staging or followup. 109 examinations of each modality were evaluated and compared to each other. Conventional staging procedures, other imaging techniques, laboratory screening, and follow-up data constituted the reference standard for comparison with image fusion. Sensitivity and specificity were calculated for CT and PET separately. Results. Sensitivity and specificity for detecting malignant lymphoma were 90% and 76% for CT and 94% and 91% for PET, respectively. A lymph node region-based analysis (comprising 14 defined anatomical regions) revealed a sensitivity of 81% and a specificity of 97% for CT and 96% and 99% for FDG PET, respectively. Only three of 109 image fusion findings needed further evaluation (false positive). Conclusion. Digital fusion of PET and CT improves the accuracy of staging, restaging, and therapy monitoring in patients with malignant lymphoma and may reduce the need for invasive diagnostic procedures. PMID:22654631
Spontaneous rectus sheath hematoma: The utility of CT angiography.
Pierro, Antonio; Cilla, Savino; Modugno, Pietro; Centritto, Enrico Maria; De Filippo, Carlo Maria; Sallustio, Giuseppina
2018-04-01
We described the utility of computed tomography (CT) angiography in detection of bleeding vessels for a rapid percutaneous arterial embolization of the spontaneous rectus sheath hematoma. A 70-year-old woman comes to our attention with acute abdominal pain and a low hemoglobin level. An unenhanced CT was performed demonstrating a large rectus sheath hematoma. A conservative management was initially established. Despite this therapy, the abdominal pain increased together with a further decrease of hemoglobin values. A CT angiography was then performed, demonstrating an active bleeding within the hematoma and addressing the patient to a rapid percutaneous arterial embolization.
Gonoi, Wataru; Okuma, Hidemi; Shirota, Go; Shintani, Yukako; Abe, Hiroyuki; Takazawa, Yutaka; Fukayama, Masashi; Ohtomo, Kuni
2015-01-01
Computed tomography (CT) is widely used in postmortem investigations as an adjunct to the traditional autopsy in forensic medicine. To date, several studies have described postmortem CT findings as being caused by normal postmortem changes. However, on interpretation, postmortem CT findings that are seemingly due to normal postmortem changes initially, may not have been mere postmortem artifacts. In this pictorial essay, we describe the common postmortem CT findings in cases of atraumatic in-hospital death and describe the diagnostic pitfalls of normal postmortem changes that can mimic real pathologic lesions. PMID:26175579
SU-C-BRB-01: Automated Dose Deformation for Re-Irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, S; Kainz, K; Li, X
Purpose: An objective of retreatment planning is to minimize dose to previously irradiated tissues. Conventional retreatment planning is based largely on best-guess superposition of the previous treatment’s isodose lines. In this study, we report a rigorous, automated retreatment planning process to minimize dose to previously irradiated organs at risk (OAR). Methods: Data for representative patients previously treated using helical tomotherapy and later retreated in the vicinity of the original disease site were retrospectively analyzed in an automated fashion using a prototype treatment planning system equipped with a retreatment planning module (Accuray, Inc.). The initial plan’s CT, structures, and planned dosemore » were input along with the retreatment CT and structure set. Using a deformable registration algorithm implemented in the module, the initially planned dose and structures were warped onto the retreatment CT. An integrated third-party sourced software (MIM, Inc.) was used to evaluate registration quality and to contour overlapping regions between isodose lines and OARs, providing additional constraints during retreatment planning. The resulting plan and the conventionally generated retreatment plan were compared. Results: Jacobian maps showed good quality registration between the initial plan and retreatment CTs. For a right orbit case, the dose deformation facilitated delineating the regions of the eyes and optic chiasm originally receiving 13 to 42 Gy. Using these regions as dose constraints, the new retreatment plan resulted in V50 reduction of 28% for the right eye and 8% for the optic chiasm, relative to the conventional plan. Meanwhile, differences in the PTV dose coverage were clinically insignificant. Conclusion: Automated retreatment planning with dose deformation and definition of previously-irradiated regions allowed for additional planning constraints to be defined to minimize re-irradiation of OARs. For serial organs that do not recover from radiation damage, this method provides a more precise and quantitative means to limit cumulative dose. This research is partially supported by Accuray, Inc.« less
Jia, Xiao-Yang; Chen, Yan-Xi; Qiang, Min-Fei; Zhang, Kun; Li, Hao-Bo; Jiang, Yu-Chen; Zhang, Yi-Jie
2017-05-01
To compare postoperative CT images with plain radiographs for measuring prognostic factors of reduction loss of fractures of the proximal part of the humerus. A total of 65 patients who sustained fractures of the proximal humerus treated with locking plates from June 2012 to October 2015 were retrospectively analyzed. There were 24 men and 41 women, with a mean age of 60.0 years (range, 22-76 years). According to the Neer classification system of proximal humeral fracture, there were 26 two-part, 27 three-part and 12 four-part fractures of the proximal part of the humerus, and all fractures were treated with open reduction and internal fixation (ORIF) using locked plating. All postoperative CT images and plain radiographs of the patients were obtained. Prognostic factors of the reduction loss were the change of neck shaft angle (NSA) and the change of humeral head height (HHH). The change of NSA and HHH were evaluated by the difference between postoperative initial and final follow-up measurement. Reduction loss was defined as the change ≥10° for NSA or ≥5 mm for HHH. The NSA and HHH were measured using plain radiographs and 3-D CT images, both initially and at final follow-up. The paired t-test was used for comparison of NSA, change of NSA, HHH, and change of HHH between two image modalities. The differences between two image modalities in the assessment of reduction loss were examined using the χ 2 -test (McNemar test). Intraclass correlation coefficients (ICC) were used to assess the intra-observer and inter-observer reliability. 3-D CT images (ICC range, 0.834-0.967) were more reliable in all parameters when compared with plain radiographs (ICC range, 0.598-0.915). Significant differences were found between the two image modalities in all parameters (plain radiographs: initial NSA = 133.6° ± 3.8°, final NSA = 130.0° ± 1.9°, initial HHH = 17.9 ± 0.9 mm, final HHH = 15.8 ± 1.5 mm; 3-D CT: initial NSA = 131.4° ± 3.4°, final NSA = 128.8° ± 1.7°, initial HHH = 16.8 ± 1.2 mm, final HHH = 14.5 ± 1.1 mm; all P < 0.05). In the assessment of reduction loss, the percentage was 16.9% (11/65) for the plain radiographs and 7.7% (5/65) for the 3-D CT scans (P < 0.05). For the 5 patients with reduction loss, which were observed by two imaging modalities, the mean Constant-Murley score was 61.0 ± 1.6. The patients with reduction loss, observed only in plain radiographs but not CT images, had good shoulder function (Constant-Murley score: 82.7 ± 1.0). Our data reveal that 3-D CT images are more reliable than plain radiographs in the assessment of the prognostic factors of reduction loss of fractures of the proximal part of the humerus with treatment of locking plates; this reliable CT technique can serve as an effective guideline for the subsequent clinical management of patients. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
Ederveen, J C; van Berckel, M M G; Nienhuijs, S W; Weber, R J P; Nederend, J
2018-06-04
Internal herniation, a serious complication after bariatric surgery, is challenging to diagnose. The aim of this study was to determine the accuracy of abdominal CT in diagnosing internal herniation. The study included consecutive patients who had undergone laparoscopic gastric bypass surgery between 1 January 2011 and 1 January 2015 at a bariatric centre of excellence. To select patients suspected of having internal herniation, reports of abdominal CT and reoperations up to 1 January 2017 were screened. CT was presumed negative for internal herniation if no follow-up CT or reoperation was performed within 90 days after the initial CT, or no internal herniation was found during reoperation. The accuracy of abdominal CT in diagnosing internal herniation was calculated using two-way contingency tables. A total of 1475 patients were included (84·7 per cent women, mean age 46·5 years, median initial BMI 41·8 kg/m 2 ). CT and/or reoperation was performed in 192 patients (13·0 per cent) in whom internal herniation was suspected. Internal herniation was proven laparoscopically in 37 of these patients. The incidence of internal herniation was 2·5 per cent. An analysis by complaint included a total of 265 episodes, for which 247 CT scans were undertaken. CT was not used to investigate 18 episodes, but internal herniation was encountered in one-third of these during reoperation. Combining the follow-up and intraoperative findings, the accuracy of CT for internal herniation had a sensitivity of 83·8 (95 per cent c.i. 67·3 to 93·2) per cent, a specificity of 87·1 (81·7 to 91·2) per cent, a positive predictive value of 53·4 (40·0 to 66·5) per cent and a negative predictive value of 96·8 (92·9 to 98·7) per cent. Abdominal CT is an important tool in diagnosing internal herniation, with a high specificity and a high negative predictive value. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.
The effects of misinterpretation of an artefact on multidetector row CT scans in children.
du Plessis, Anne-Marie; Theron, Salomine; Andronikou, Savvas
2009-02-01
Artefacts reflect problems with radiographic technique rather than true pathology. These may be misinterpreted as pathology with serious consequences. An artefact caused such problems in one paediatric imaging department. To determine the incidence, and consequences of misinterpretation, of a CT artefact in a paediatric imaging department. A retrospective review of images and reports of paediatric CT scans over a set period with a known artefact was performed. Reports were correlated with reviewers' evaluation of the presence of artefact and reviewed for correct identification of artefact, misinterpretation as pathology, and action taken as a result. A total of 74 CT scans had been performed over the study period and an artefact detected by reviewers on 32 (43%). Six (18.75%) of these were misinterpreted as pathology, of which three (9.4%) were reported as tuberculous granulomas, two (6.2%) as haemorrhages and one (3.1%) as an unknown hyperdensity. Two patients (6.2%) had subsequent MRI studies performed, and treatment for tuberculosis was continued in one patient (3.1%). No initial report identified the artefact. One-fifth of the scans with the artefact were misinterpreted as pathology and half of these misinterpretations led to further action. Artefacts result in false diagnoses and unnecessary investigations; vigilance is needed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garnon, Julien, E-mail: juliengarnon@gmail.com; Koch, Guillaume, E-mail: Guillaume.koch@gmail.com; Ramamurthy, Nitin, E-mail: Nitin-ramamurthy@hotmail.com
ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up wasmore » undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.« less
Potential impact of 68Ga-PSMA-11 PET/CT on prostate cancer definitive radiation therapy planning.
Calais, Jérémie; Kishan, Amar U; Cao, Minsong; Fendler, Wolfgang P; Eiber, Matthias; Herrmann, Ken; Ceci, Francesco; Reiter, Robert E; Rettig, Matthew B; Hegde, John V; Shaverdian, Narek; King, Christopher R; Steinberg, Michael L; Czernin, Johannes; Nickols, Nicholas G
2018-04-13
Background: Standard-of-care imaging for initial staging of prostate cancer (PCa) underestimates disease burden. Prostate specific membrane antigen (PSMA) positron emission tomography/ computed tomography (PET/CT) detects PCa metastasis with superior accuracy with potential impact definitive radiation therapy (RT) planning for non-metastatic PCa. Objectives: i) To determine how often definitive PCa RT planning based on standard target volumes cover 68 Ga-PSMA-11 PET/CT defined disease, and ii) To assess the potential impact of 68 Ga-PSMA-11 PET/CT on definitive PCa RT planning. Patients and Methods: This is a post-hoc analysis of an intention to treat population of 73 patients with localized PCa without prior local therapy who underwent 68 Ga-PSMA PET/CT for initial staging as part of an Investigational New Drug trial. 11/73 were intermediate-risk (15%), 33/73 were high-risk (45%), 22/73 were very high risk (30%), and 7/73 were N1 (9.5%). Clinical target volumes (CTVs) that included the prostate, seminal vesicles, and pelvic lymph nodes (LNs) using Radiation Therapy Oncology Group (RTOG) consensus guidelines were contoured on the CT portion of the PET/CT by a radiation oncologist blinded to the PET findings. 68 Ga-PSMA-11 PET/CT images were analyzed by a nuclear medicine physician. PSMA-positive lesions not covered by planning volumes based on the CTVs were considered to have a major potential impact on treatment planning. Results: All patients had PSMA-positive primary prostate lesion(s). 25/73 (34%) and 7/73 (9.5%) had PSMA-positive pelvic nodal and distant metastases, respectively. The sites of nodal metastases in decreasing order of frequency were external iliac (20.5%), common iliac (13.5%), internal iliac (12.5%) obturator (12.5%), perirectal (4%), abdominal (4%), upper-diaphragm (4%), and presacral (1.5%). The median size of the nodal lesions was 6 mm (range 4-24 mm). RT planning based on the CTVs covered 69/73 (94.5%) of primary disease and 20/25 (80%) of pelvic nodal disease, on a per-patient analysis. Conclusion: 68 Ga-PSMA-11 PET/CT had a major impact on intended definitive PCa RT planning in 12/73 of patients (16.5%) when RT fields covered the prostate, seminal vesicles and the pelvic LNs, and in 25/66 of patients (37%) when RT fields covered only the prostate and seminal vesicles (without pelvic LNs). Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
NASA Astrophysics Data System (ADS)
Semprini, L.; Azizian, M.
2012-12-01
The demonstration of transformation of chlorinated aliphatic compounds (CAHs) in the subsurface is a challenge, especially when the products are carbon dioxide (CO2) and chloride ion. The groundwater contaminant carbon tetrachloride (CT) is of particular interest since a broad range of transformation products can be potentially formed under anaerobic conditions. The ability to demonstrate the transformation of CT to CO2 as a non toxic endproduct, is also of great interest. Results will be presented from a continuous flow column study where 13C labeled CT was used to demonstrate its transformation to CO2. The column was packed with a quartz sand and bioaugmented the Evanite Culture (EV) that is capable of transforming tetrachloroethene (PCE) to ethene. The column was continously fed a synthetic groundwater that was amended with PCE (0.10 mM) and either formate (1.5 mM) or lactate (1.1 mM), which ferments to produce hydrogen (H2) as the ultimate electron donor. Earlier CT transformation studies with the column, in the absence of sulfate reduction, and with formate added as a donor found CT (0.015 mM) was over 98% transformed with about 20% converted to chloroform (CF) (0.003 mM) and with a transient detection of chloromethane (CM). Methane and carbon disulfide, as potential products, were not detected. Neither CT nor CF inhibited the reductive dehalogenation of PCE to ethene. A series of transient studies conducted after these initial CT transformation tests, but in the absence of CT, showed formate remained an effective substrate for maintaining sulfate reduction and PCE transformation. Lactate, which was effectively fermented prior to CT addition, was not effectively fermented, with propionate accumulating as a fermentation product. When lactate was added, PCE was mainly transformed to cis-dichloroethene (cis-DCE) and VC, and sulfate reduction did not occur. In order to restore effective lactate fermentation the column was then bioaugmented with an EV culture that was capable of lactate fermentation. After bioaugmentation, effective lactate fermentation, sulfate reduction and PCE transformation to ethene was achieved. Unlabeled CT (0.015 mM) addition was then started and complete transformation was achieved with a transient build-up of CF and chloromethane, which were subsequently removed below their detection limits. CT continued to be completely transformed after the influent concentration was increased to 0.03 mM. 13C labeled CT (0.03 mM) was then added to the column. GC-MS analysis showed that 13C labeled CO2 was formed at near stoichiometric levels to the CT that was transformed. The results clearly demonstrate that CT can being transformed to CO2 at high CT concentrations, while maintaining effective PCE dehalogenation, sulfate reduction and lactate fermentation. The results also illustrate the great potential of using 13C labeled compounds in subsurface investigations.
SU-F-P-03: Management of Time to Treatment Inititation: Case for An Electronic Whiteboard
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adnani, N
2016-06-15
Purpose: To determine if data mining of an electronic whiteboard improves the management of the Time to Treatment Initiation (TTI) in radiation oncology. Methods: An electronic whiteboard designed to help in managing the planning workflow and improves communication regarding patient planning progress was used to record the dates at which each phase of the planning process began or completed. These are CT Sim date, Plan Start, Physician Review, Physicist Review, Approval for Treatment Delivery, Setup or Verification of Simulation. Results: During clinical implementation, the electronic whiteboard was able to fulfill its primary objective of providing a transparent account of themore » planning progress of each patient. Peer pressure also meant that individual tasks, such as contouring, were easily brought to the attention of the responsible party and prioritized accordingly. Data mining to analyze the electronic whiteboard per patient (figure 1), per diagnosis (figure 2), per treatment modality (figure 3), per physician (figure 4), per planner (figure 5), etc., added another sophisticated tool in the management of Time to Treatment Initiation without compromising quality of the plans being generated. A longer than necessary time between CT Sim and Plan Start can be discussed among the members of the treatment team as an indication of inadequate/outdated CT Simulator, Contouring Tools, Image Fusion Tools, Other Imaging Studies (MRI, PET/CT) performed, etc. The same for the Plan Start to Physician Review where an extended time than expected may be due unrealistic planning goals, limited planning system features, etc. Conclusion: An Electronic Whiteboard in radiation oncology is not only helping with organizing planning workflow, it is also a potent tool that can be used to reduce the Time to Treatment Initiation by providing the clinic with hard data about the duration of each phase treatment planning as a function of different variable affecting the planning process. The work is supported by the Global Medical Physics Institute.« less
Yoon, H M; Lee, J S; Hwang, J-Y; Cho, Y A; Yoon, H-K; Yu, J; Hong, S-J; Yoon, C H
2015-05-01
Intravenous pulse methylprednisolone therapy (IPMT) is an important treatment option for post-infectious obliterative bronchiolitis (OB), although it must be used carefully and only in selected patients because of its drawbacks. This study evaluated whether CT and clinical features of children with post-infectious OB can predict their responsiveness to IPMT. We searched the medical records for patients (less than 18 years of age) who were diagnosed with post-infectious OB between January 2000 and December 2011. 17 children who received IPMT were included in this study. All underwent chest CT before and after IPMT. The radiological features seen on pre-treatment CT were recorded. The air-trapping area percentages on pre- and post-treatment CT images were determined. The nine patients who exhibited decreased air trapping on post-treatment CT scans relative to pre-treatment scans were classed as responders. The patient ages and time from initial pneumonia to IPMT were recorded. All responders and only four non-responders had thickened bronchial walls before treatment (p = 0.029). The two groups did not differ significantly in terms of bronchiolitis, bronchiectasis or the extent of air trapping, although the responders had a significantly shorter median interval between initial pneumonia and IPMT (4 vs 50 months; p = 0.005) and were significantly younger (median, 2.0 vs 7.5 years; p = 0.048). Immediate IPMT may improve the degree of air trapping in children with post-infectious OB if they show a thickened bronchial wall on CT. Children with post-infectious OB may respond favourably to IPMT when pre-treatment CT indicates bronchial-wall thickening.
Ultrasonography versus computed tomography for suspected nephrolithiasis.
Smith-Bindman, Rebecca; Aubin, Chandra; Bailitz, John; Bengiamin, Rimon N; Camargo, Carlos A; Corbo, Jill; Dean, Anthony J; Goldstein, Ruth B; Griffey, Richard T; Jay, Gregory D; Kang, Tarina L; Kriesel, Dana R; Ma, O John; Mallin, Michael; Manson, William; Melnikow, Joy; Miglioretti, Diana L; Miller, Sara K; Mills, Lisa D; Miner, James R; Moghadassi, Michelle; Noble, Vicki E; Press, Gregory M; Stoller, Marshall L; Valencia, Victoria E; Wang, Jessica; Wang, Ralph C; Cummings, Steven R
2014-09-18
There is a lack of consensus about whether the initial imaging method for patients with suspected nephrolithiasis should be computed tomography (CT) or ultrasonography. In this multicenter, pragmatic, comparative effectiveness trial, we randomly assigned patients 18 to 76 years of age who presented to the emergency department with suspected nephrolithiasis to undergo initial diagnostic ultrasonography performed by an emergency physician (point-of-care ultrasonography), ultrasonography performed by a radiologist (radiology ultrasonography), or abdominal CT. Subsequent management, including additional imaging, was at the discretion of the physician. We compared the three groups with respect to the 30-day incidence of high-risk diagnoses with complications that could be related to missed or delayed diagnosis and the 6-month cumulative radiation exposure. Secondary outcomes were serious adverse events, related serious adverse events (deemed attributable to study participation), pain (assessed on an 11-point visual-analogue scale, with higher scores indicating more severe pain), return emergency department visits, hospitalizations, and diagnostic accuracy. A total of 2759 patients underwent randomization: 908 to point-of-care ultrasonography, 893 to radiology ultrasonography, and 958 to CT. The incidence of high-risk diagnoses with complications in the first 30 days was low (0.4%) and did not vary according to imaging method. The mean 6-month cumulative radiation exposure was significantly lower in the ultrasonography groups than in the CT group (P<0.001). Serious adverse events occurred in 12.4% of the patients assigned to point-of-care ultrasonography, 10.8% of those assigned to radiology ultrasonography, and 11.2% of those assigned to CT (P=0.50). Related adverse events were infrequent (incidence, 0.4%) and similar across groups. By 7 days, the average pain score was 2.0 in each group (P=0.84). Return emergency department visits, hospitalizations, and diagnostic accuracy did not differ significantly among the groups. Initial ultrasonography was associated with lower cumulative radiation exposure than initial CT, without significant differences in high-risk diagnoses with complications, serious adverse events, pain scores, return emergency department visits, or hospitalizations. (Funded by the Agency for Healthcare Research and Quality.).
Devaraj, Bikash; Liu, Wendy; Tatum, James; Cologne, Kyle; Kaiser, Andreas M
2016-03-01
The best management for diverticulitis with abscess formation remains unknown. The purpose of this study was to determine the natural course and outcomes of patients with medically treated diverticular abscess. We conducted a retrospective review of all patients at our institution with diverticular abscess confirmed by CT from 2004 to 2014. This study was conducted in a tertiary referral hospital. A total of 1194 patients were treated for acute diverticulitis in 10 years; 210 patients with CT-documented diverticular abscess were analyzed (140 men (66.7%) and 70 women (33.3%); median age 45 years; range, 23-84 years). Overall recurrence and disease complication rates, as well as the need for subsequent operation after initial successful nonsurgical management, were measured, along with analysis of the whole cohort and the subgroup of patients with percutaneous drainage for diverticular abscess. During the initial presentation, 25 patients failed nonoperative management and required an urgent operation. A total of 185 patients were initially successfully managed without surgery and were discharged from the hospital. Of these, recurrent diverticulitis developed in 112 (60.5%) after an average time interval of 5.3 months (range, 0.8-20.0 months); 47 patients (42%) experienced more than 1 episode. The modified Hinchey stage at time of recurrence (compared with index stay) increased in 51 patients (45.6%). Seventy one (63%) of 112 recurrences showed local disease complications (recurrent abscess, fistula, stricture, or peritonitis). Fistula formation (colovesicular/colovaginal/colocutaneous) and recurrent abscess were the 2 most frequent complications. Twenty nine (26%) of 112 recurrences required an urgent operation; overall, 66 (59%) of 112 patients eventually underwent surgery at our institution. The original abscess size in patients who later developed recurrences was significantly larger than in patients who did not develop recurrence (5.3 vs 3.2 cm; p < 0.001). Paradoxically, larger abscesses also had a higher chance of successful CT-guided drainage (average size, 6.5 cm; range, 1.1-14 cm), yet CT-guided drainage did not change the overall outcome. Of 65 (31.0%) of 210 patients with CT-guided drainage, 45 (73.8%) of 61 after initial success experienced a recurrence. Furthermore, local disease complications at the time of recurrence were noted in 32 of 61 patients (52.5% of all CT-guided drainage, 71.1% of post-CT-guided drainage recurrences), and 13 (29.2%) of 45 patients with recurrence after successful CT-guided drainage subsequently required an urgent operation. The study was limited by its retrospective noncomparative design. Diverticular abscesses represent complicated diverticulitis and are associated with a high risk of recurrences and disease complications. Recurrences (contrary to other series) were often more severe than the index presentation. The successful CT-guided drainage of a diverticular abscess does not appear to lower the risks of future recurrence or complication rates and frequently is only a bridge to surgery. After initial successful nonoperative management, patients with diverticular abscess should be offered interval elective colectomy (see Video, Supplemental Digital Content 1, http://links.lww.com/DCR/A216).
Volvulus of the ascending colon in a non-rotated midgut: Plain film and MDCT findings.
Camera, Luigi; Calabrese, Milena; Mainenti, Pier Paolo; Masone, Stefania; Vecchio, Walter Del; Persico, Giovanni; Salvatore, Marco
2012-10-28
Colonic volvulus is a relatively uncommon cause of large bowel obstruction usually involving mobile, intra-peritoneal, colonic segments. Congenital or acquired anatomic variation may be associated with an increased risk of colonic volvulus which can occasionally involve retro-peritoneal segments. We report a case of 54-year-old female who presented to our Institution to perform a plain abdominal film series for acute onset of cramping abdominal pain. Both the upright and supine films showed signs of acute colonic obstruction which was thought to be due to an internal hernia of the transverse colon into the lesser sac. The patient was therefore submitted to a multi-detector contrast-enhanced computed tomography (CT). CT findings were initially thought to be consistent with the presumed diagnosis of internal hernia but further evaluation and coronal reformatting clearly depicted the presence of a colonic volvulus possibly resulting from a retro-gastric colon. At surgery, a volvulus of the ascending colon was found and a right hemi-colectomy had to be performed. However, a non rotated midgut with a right-sided duodeno-jejunal flexure and a left sided colon was also found at laparotomy and overlooked in the pre-operative CT. Retrospective evaluation of CT images was therefore performed and a number of CT signs of intestinal malrotation could be identified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teramoto, Atsushi, E-mail: teramoto@fujita-hu.ac.jp; Fujita, Hiroshi; Yamamuro, Osamu
Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using anmore » active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules using PET/CT images.« less
NASA Astrophysics Data System (ADS)
He, Nana; Zhang, Xiaolong; Zhao, Juanjuan; Zhao, Huilan; Qiang, Yan
2017-07-01
While the popular thin layer scanning technology of spiral CT has helped to improve diagnoses of lung diseases, the large volumes of scanning images produced by the technology also dramatically increase the load of physicians in lesion detection. Computer-aided diagnosis techniques like lesions segmentation in thin CT sequences have been developed to address this issue, but it remains a challenge to achieve high segmentation efficiency and accuracy without much involvement of human manual intervention. In this paper, we present our research on automated segmentation of lung parenchyma with an improved geodesic active contour model that is geodesic active contour model based on similarity (GACBS). Combining spectral clustering algorithm based on Nystrom (SCN) with GACBS, this algorithm first extracts key image slices, then uses these slices to generate an initial contour of pulmonary parenchyma of un-segmented slices with an interpolation algorithm, and finally segments lung parenchyma of un-segmented slices. Experimental results show that the segmentation results generated by our method are close to what manual segmentation can produce, with an average volume overlap ratio of 91.48%.
Sci—Thur PM: Imaging — 06: Canada's National Computed Tomography (CT) Survey
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wardlaw, GM; Martel, N; Blackler, W
2014-08-15
The value of computed tomography (CT) in medical imaging is reflected in its' increased use and availability since the early 1990's; however, given CT's relatively larger exposures (vs. planar x-ray) greater care must be taken to ensure that CT procedures are optimised in terms of providing the smallest dose possible while maintaining sufficient diagnostic image quality. The development of CT Diagnostic Reference Levels (DRLs) supports this process. DRLs have been suggested/supported by international/national bodies since the early 1990's and widely adopted elsewhere, but not on a national basis in Canada. Essentially, CT DRLs provide guidance on what is considered goodmore » practice for common CT exams, but require a representative sample of CT examination data to make any recommendations. Canada's National CT Survey project, in collaboration with provincial/territorial authorities, has collected a large national sample of CT practice data for 7 common examinations (with associated clinical indications) of both adult and pediatric patients. Following completion of data entry into a common database, a survey summary report and recommendations will be made on CT DRLs from this data. It is hoped that these can then be used by local regions to promote CT practice optimisation and support any dose reduction initiatives.« less
Postthrombolysis hemorrhage risk is affected by stroke assessment bias between hemispheres
Singer, O.C.; Gotzler, B.; Vatankhah, B.; Boy, S.; Fiehler, J.; Lansberg, M.G.; Albers, G.W.; Kastrup, A.; Rovira, A.; Gass, A.; Rosso, C.; Derex, L.; Kim, J.S.; Heuschmann, P.
2011-01-01
Objective: Stroke symptoms in right hemispheric stroke tend to be underestimated in clinical assessment scales, resulting in greater infarct volumes in right as compared to left hemispheric strokes despite similar clinical stroke severity. We hypothesized that patients with right hemispheric nonlacunar stroke are at higher risk for secondary intracerebral hemorrhage after thrombolysis despite similar stroke severity. Methods: We analyzed data of 2 stroke cohorts with CT-based and MRI-based imaging before thrombolysis. Initial stroke severity was measured with the NIH Stroke Scale (NIHSS). Lacunar strokes were excluded through either the presence of cortical symptoms (CT cohort) or restriction to patients with prestroke diffusion-weighted imaging (DWI) lesion size >3.75 mL (MRI cohort). Probabilities of having a parenchymal hematoma were determined using multivariate logistic regression. Results: A total of 392 patients in the CT cohort and 400 patients in the MRI cohort were evaluated. Although NIHSS scores were similar in strokes of both hemispheres (median NIHSS: CT: 15 vs 13, MRI: 14 vs 16), the frequencies of parenchymal hematoma were higher in right hemispheric compared to left hemispheric strokes (CT: 12.4% vs 5.7%, MRI: 10.4% vs 6.8%). After adjustment for potential confounders (but not pretreatment lesion volume), the probability of parenchymal hematoma was higher in right hemispheric nonlacunar strokes (CT: odds ratio [OR] 2.3; 95% confidence interval [CI] 1.08–4.89; p = 0.032) and showed a borderline significant effect in the MRI cohort (OR 2.1; 95% CI 0.98–4.49; p = 0.057). Adjustment for pretreatment DWI lesion size eliminated hemispheric differences in hemorrhage risk. Conclusions: Higher hemorrhage rates in right hemispheric nonlacunar strokes despite similar stroke severity may be caused by clinical underestimation of the proportion of tissue at bleeding risk. PMID:21248275
Hakimé, Antoine; Peddi, Himaja; Hines-Peralta, Andrew U; Wilcox, Carol J; Kruskal, Jonathan; Lin, Shezhang; de Baere, Thierry; Raptopoulos, Vassilios D; Goldberg, S Nahum
2007-06-01
To prospectively compare single- and multisection computed tomographic (CT) perfusion for tumor blood flow determination in an animal model. All animal protocols and experiments were approved by the institutional animal care and use committee before the study was initiated. R3230 mammary adenocarcinoma was implanted in 11 rats. Tumors (18-20 mm) were scanned with dynamic 16-section CT at baseline and after administration of arsenic trioxide, which is known to cause acute reduction in blood flow. The concentration of arsenic was titrated (0-6 mg of arsenic per kilogram of body weight) to achieve a defined blood flow reduction (0%-75%) from baseline levels at 60 minutes, as determined with correlative laser Doppler flowmetry. The mean blood flow was calculated for each of four 5-mm sections that covered the entire tumor, as well as for the entire tumor after multiple sections were processed. Measurements obtained with both methods were correlated with laser Doppler flowmetry measurements. Interobserver agreement was determined for two blinded radiologists, who calculated the percentage of blood flow reduction for the "most representative" single sections at baseline and after arsenic administration. These results were compared with the interobserver variability of the same radiologists obtained by summing blood flow changes for the entire tumor volume. Overall correlations for acute blood flow reduction were demonstrated between laser Doppler flowmetry and the two CT perfusion approaches (single-section CT, r=0.85 and r(2)=0.73; multisection CT, r=0.93 and r(2)=0.87; pooled data, P=.01). CT perfusion disclosed marked heterogeneity of blood flow, with variations of 36% +/- 13 between adjacent 5-mm sections. Given these marked differences, interobserver agreement was much lower for single-section CT (standard deviation, 0.22) than for multisection CT (standard deviation, 0.10; P=.01). Multisection CT perfusion techniques may provide an accurate and more reproducible method of tumor perfusion surveillance than comparison of single representative tumor sections. (c) RSNA, 2007.
NASA Astrophysics Data System (ADS)
Tanaka, Osamu; Iida, Takayoshi; Komeda, Hisao; Tamaki, Masayoshi; Seike, Kensaku; Kato, Daiki; Yokoyama, Takamasa; Hirose, Shigeki; Kawaguchi, Daisuke
2016-12-01
Visualization of markers is critical for imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI). However, the size of the marker varies according to the imaging technique. While a large-sized marker is more useful for visualization in MRI, it results in artifacts on CT and causes substantial pain on administration. In contrast, a small-sized marker reduces the artifacts on CT but hampers MRI detection. Herein, we report a new ironcontaining marker and compare its utility with that of non-iron-containing markers. Five patients underwent CT/MRI fusion-based intensity-modulated radiotherapy, and the markers were placed by urologists. A Gold Anchor™ (GA; diameter, 0.28 mm; length, 10 mm) was placed using a 22G needle on the right side of the prostate. A VISICOIL™ (VIS; diameter, 0.35 mm; length, 10 mm) was placed using a 19G needle on the left side. MRI was performed using T2*-weighted imaging. Three observers evaluated and scored the visual qualities of the acquired images. The mean score of visualization was almost identical between the GA and VIS in radiography and cone-beam CT (Novalis Tx). The artifacts in planning CT were slightly larger using the GA than using the VIS. The visualization of the marker on MRI using the GA was superior to that using the VIS. In conclusion, the visualization quality of radiography, conebeam CT, and planning CT was roughly equal between the GA and VIS. However, the GA was more strongly visualized than was the VIS on MRI due to iron containing.
Kim, Tae Won; Peeters, Marc; Thomas, Anne L; Gibbs, Peter; Hool, Kristina; Zhang, Jianqi; Ang, Agnes; Bach, Bruce Allen; Price, Timothy
2018-06-13
The accumulation of emergent RAS mutations during anti-epidermal growth factor receptor (EGFR) therapy is of interest as a mechanism for acquired resistance to anti-EGFR treatment. Plasma analysis of circulating tumor (ct) DNA is a minimally invasive and highly sensitive method to determine RAS mutational status. This biomarker analysis of the global phase III ASPECCT study used next-generation sequencing to detect expanded RAS ctDNA mutations in panitumumab-treated patients. Plasma samples collected at baseline and posttreatment were analyzed categorically for the presence of RAS mutations by the Plasma Select -R™ 64-gene panel at 0.1% sensitivity. Among panitumumab-treated patients with evaluable plasma samples at baseline (n = 238), 188 (79%) were wild-type (WT) RAS, and 50 (21%) were mutant RAS Of the 188 patients with baseline ctDNA WT RAS status, 164 had evaluable posttreatment results with a 32% rate of emergent RAS mutations. The median overall survival (OS) for WT and RAS mutant status by ctDNA at baseline was 13.7 (95% confidence interval: 11.5-15.4) and 7.9 months (6.4-9.6), respectively ( P < 0.0001). Clinical outcomes were not significantly different between patients with and without emergent ctDNA RAS mutations. Although patients with baseline ctDNA RAS mutations had worse outcomes than patients who were WT RAS before initiating treatment, emergent ctDNA RAS mutations were not associated with less favorable patient outcomes in panitumumab-treated patients. Further research is needed to determine a clinically relevant threshold for baseline and emergent ctDNA RAS mutations. Copyright ©2018, American Association for Cancer Research.
XCAT/DRASIM: a realistic CT/human-model simulation package
NASA Astrophysics Data System (ADS)
Fung, George S. K.; Stierstorfer, Karl; Segars, W. Paul; Taguchi, Katsuyuki; Flohr, Thomas G.; Tsui, Benjamin M. W.
2011-03-01
The aim of this research is to develop a complete CT/human-model simulation package by integrating the 4D eXtended CArdiac-Torso (XCAT) phantom, a computer generated NURBS surface based phantom that provides a realistic model of human anatomy and respiratory and cardiac motions, and the DRASIM (Siemens Healthcare) CT-data simulation program. Unlike other CT simulation tools which are based on simple mathematical primitives or voxelized phantoms, this new simulation package has the advantages of utilizing a realistic model of human anatomy and physiological motions without voxelization and with accurate modeling of the characteristics of clinical Siemens CT systems. First, we incorporated the 4D XCAT anatomy and motion models into DRASIM by implementing a new library which consists of functions to read-in the NURBS surfaces of anatomical objects and their overlapping order and material properties in the XCAT phantom. Second, we incorporated an efficient ray-tracing algorithm for line integral calculation in DRASIM by computing the intersection points of the rays cast from the x-ray source to the detector elements through the NURBS surfaces of the multiple XCAT anatomical objects along the ray paths. Third, we evaluated the integrated simulation package by performing a number of sample simulations of multiple x-ray projections from different views followed by image reconstruction. The initial simulation results were found to be promising by qualitative evaluation. In conclusion, we have developed a unique CT/human-model simulation package which has great potential as a tool in the design and optimization of CT scanners, and the development of scanning protocols and image reconstruction methods for improving CT image quality and reducing radiation dose.
Friesen, Melissa C.; Wheeler, David C.; Vermeulen, Roel; Locke, Sarah J.; Zaebst, Dennis D.; Koutros, Stella; Pronk, Anjoeka; Colt, Joanne S.; Baris, Dalsu; Karagas, Margaret R.; Malats, Nuria; Schwenn, Molly; Johnson, Alison; Armenti, Karla R.; Rothman, Nathanial; Stewart, Patricia A.; Kogevinas, Manolis; Silverman, Debra T.
2016-01-01
Objectives: To efficiently and reproducibly assess occupational diesel exhaust exposure in a Spanish case-control study, we examined the utility of applying decision rules that had been extracted from expert estimates and questionnaire response patterns using classification tree (CT) models from a similar US study. Methods: First, previously extracted CT decision rules were used to obtain initial ordinal (0–3) estimates of the probability, intensity, and frequency of occupational exposure to diesel exhaust for the 10 182 jobs reported in a Spanish case-control study of bladder cancer. Second, two experts reviewed the CT estimates for 350 jobs randomly selected from strata based on each CT rule’s agreement with the expert ratings in the original study [agreement rate, from 0 (no agreement) to 1 (perfect agreement)]. Their agreement with each other and with the CT estimates was calculated using weighted kappa (κ w) and guided our choice of jobs for subsequent expert review. Third, an expert review comprised all jobs with lower confidence (low-to-moderate agreement rates or discordant assignments, n = 931) and a subset of jobs with a moderate to high CT probability rating and with moderately high agreement rates (n = 511). Logistic regression was used to examine the likelihood that an expert provided a different estimate than the CT estimate based on the CT rule agreement rates, the CT ordinal rating, and the availability of a module with diesel-related questions. Results: Agreement between estimates made by two experts and between estimates made by each of the experts and the CT estimates was very high for jobs with estimates that were determined by rules with high CT agreement rates (κ w: 0.81–0.90). For jobs with estimates based on rules with lower agreement rates, moderate agreement was observed between the two experts (κ w: 0.42–0.67) and poor-to-moderate agreement was observed between the experts and the CT estimates (κ w: 0.09–0.57). In total, the expert review of 1442 jobs changed 156 probability estimates, 128 intensity estimates, and 614 frequency estimates. The expert was more likely to provide a different estimate when the CT rule agreement rate was <0.8, when the CT ordinal ratings were low to moderate, or when a module with diesel questions was available. Conclusions: Our reliability assessment provided important insight into where to prioritize additional expert review; as a result, only 14% of the jobs underwent expert review, substantially reducing the exposure assessment burden. Overall, we found that we could efficiently, reproducibly, and reliably apply CT decision rules from one study to assess exposure in another study. PMID:26732820
In Situ Imaging during Compression of Plastic Bonded Explosives for Damage Modeling
NASA Astrophysics Data System (ADS)
Yeager, John; Manner, Virginia; Patterson, Brian; Walters, David; Cordes, Nikolaus; Henderson, Kevin; Tappan, Bryce; Luscher, Darby
2017-06-01
The microstructure of plastic bonded explosives (PBXs) is known to influence behavior during insults such as deformation, heating or initiation to detonation. Obtaining three-dimensional microstructural data can be difficult due in part to fragility of the material and small feature size. X-ray computed tomography (CT) is an ideal characterization technique but the explosive crystals and binder in formulations such as PBX 9501 do not have sufficient x-ray contrast to differentiate between the components. Here, we have formulated several PBXs using octahydro-1,3,5,7-tetranitro-1,3,5,7- tetrazocine (HMX) crystals and low-density binder systems. The full three-dimensional microstructure of these samples has been characterized using microscale CT during uniaxial mechanical compression in an interrupted in situ modality. The rigidity of the binder was observed to significantly influence fracture, crystal-binder delamination, and material flow. Additionally, the segmented, 3D images were meshed for finite element simulation. Initial results of the mesoscale modeling exhibit qualitatively similar delamination. Los Alamos National Laboratory - LDRD.
Follow-up brain imaging of 37 children with congenital Zika syndrome: case series study.
Petribu, Natacha Calheiros de Lima; Aragao, Maria de Fatima Vasco; van der Linden, Vanessa; Parizel, Paul; Jungmann, Patricia; Araújo, Luziany; Abath, Marília; Fernandes, Andrezza; Brainer-Lima, Alessandra; Holanda, Arthur; Mello, Roberto; Sarteschi, Camila; Duarte, Maria do Carmo Menezes Bezerra
2017-10-13
Objective To compare initial brain computed tomography (CT) scans with follow-up CT scans at one year in children with congenital Zika syndrome, focusing on cerebral calcifications. Design Case series study. Setting Barão de Lucena Hospital, Pernambuco state, Brazil. Participants 37 children with probable or confirmed congenital Zika syndrome during the microcephaly outbreak in 2015 who underwent brain CT shortly after birth and at one year follow-up. Main outcome measure Differences in cerebral calcification patterns between initial and follow-up scans. Results 37 children were evaluated. All presented cerebral calcifications on the initial scan, predominantly at cortical-white matter junction. At follow-up the calcifications had diminished in number, size, or density, or a combination in 34 of the children (92%, 95% confidence interval 79% to 97%), were no longer visible in one child, and remained unchanged in two children. No child showed an increase in calcifications. The calcifications at the cortical-white matter junction which were no longer visible at follow-up occurred predominately in the parietal and occipital lobes. These imaging changes were not associated with any clear clinical improvements. Conclusion The detection of cerebral calcifications should not be considered a major criterion for late diagnosis of congenital Zika syndrome, nor should the absence of calcifications be used to exclude the diagnosis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
CT liver volumetry using geodesic active contour segmentation with a level-set algorithm
NASA Astrophysics Data System (ADS)
Suzuki, Kenji; Epstein, Mark L.; Kohlbrenner, Ryan; Obajuluwa, Ademola; Xu, Jianwu; Hori, Masatoshi; Baron, Richard
2010-03-01
Automatic liver segmentation on CT images is challenging because the liver often abuts other organs of a similar density. Our purpose was to develop an accurate automated liver segmentation scheme for measuring liver volumes. We developed an automated volumetry scheme for the liver in CT based on a 5 step schema. First, an anisotropic smoothing filter was applied to portal-venous phase CT images to remove noise while preserving the liver structure, followed by an edge enhancer to enhance the liver boundary. By using the boundary-enhanced image as a speed function, a fastmarching algorithm generated an initial surface that roughly estimated the liver shape. A geodesic-active-contour segmentation algorithm coupled with level-set contour-evolution refined the initial surface so as to more precisely fit the liver boundary. The liver volume was calculated based on the refined liver surface. Hepatic CT scans of eighteen prospective liver donors were obtained under a liver transplant protocol with a multi-detector CT system. Automated liver volumes obtained were compared with those manually traced by a radiologist, used as "gold standard." The mean liver volume obtained with our scheme was 1,520 cc, whereas the mean manual volume was 1,486 cc, with the mean absolute difference of 104 cc (7.0%). CT liver volumetrics based on an automated scheme agreed excellently with "goldstandard" manual volumetrics (intra-class correlation coefficient was 0.95) with no statistically significant difference (p(F<=f)=0.32), and required substantially less completion time. Our automated scheme provides an efficient and accurate way of measuring liver volumes.
2006-05-01
d). (e) In the histogram analysis eld units are observed initially for voxels located on the d to 250 Hounsfield units.ses (a) el the tration...CT10, CT20, and CT30. Histogram ximum difference of 250 Hounsfield units . Only 0.01% d units.d imag ts a mand finite-element model. The fluid flow...cause Hounsfield unit calibration problems. While this does not seem to influence the image registration, the use of CBCT for dose calculation should
Arora, Saurabh; Damle, Nishikant Avinash; Aggarwal, Sameer; Passah, Averilicia; Behera, Abhishek; Arora, Geetanjali; Bal, Chandrasekhar; Tripathi, Madhavi
2018-06-01
We present here a case of metastatic adrenocortical carcinoma with bilateral lung nodules. The patient had been treated with mitotane therapy initially and then was later referred for chemotherapy. There was progression of disease noted on the F-FDG PET/CT. Ga prostate-specific membrane antigen (PSMA) PET/CT was planned to explore the possibility of future treatment with Lu-DKFZ-PSMA-617. It revealed peripheral increased uptake of Ga-HBED-CC-PSMA equal to liver uptake.
Wang, Danyang; Huo, Yanlei; Chen, Suyun; Wang, Hui; Ding, Yingli; Zhu, Xiaochun; Ma, Chao
2018-01-01
18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) is the reference standard in staging of 18 F-FDG-avid lymphomas; however, there is no recommended functional imaging modality for indolent lymphomas. Therefore, we aimed to compare the performance of whole-body magnetic resonance imaging (WB-MRI) with that of 18 F-FDG PET/CT for lesion detection and initial staging in patients with aggressive or indolent lymphoma. We searched the MEDLINE, EMBASE, and CENTRAL databases for studies that compared WB-MRI with 18 F-FDG PET/CT for lymphoma staging or lesion detection. The methodological quality of the studies was assessed using version 2 of the "Quality Assessment of Diagnostic Accuracy Studies" tool. The pooled staging accuracy ( μ ) of WB-MRI and 18 F-FDG PET/CT for initial staging and for assessing possible heterogeneity ( χ 2 ) across studies were calculated using commercially available software. Eight studies comprising 338 patients were included. In terms of staging, the meta-analytic staging accuracies of WB-MRI and 18 F-FDG PET/CT for Hodgkin lymphoma and aggressive non-Hodgkin lymphoma (NHL) were 98% (95% CI, 94%-100%) and 98% (95% CI, 94%-100%), respectively. The pooled staging accuracy of 18 F-FDG PET/CT dropped to 87% (95% CI, 72%-97%) for staging in patients with indolent lymphoma, whereas that of WB-MRI remained 96% (95% CI, 91%-100%). Subgroup analysis indicated an even lower staging accuracy of 18 F-FDG PET/CT for staging of less FDG-avid indolent NHLs (60%; 95% CI, 23%-92%), in contrast to the superior performance of WB-MRI (98%; 95% CI, 88%-100%). WB-MRI is a promising radiation-free imaging technique that may serve as a viable alternative to 18 F-FDG PET/CT for staging of 18 FDG-avid lymphomas, where 18 F-FDG PET/CT remains the standard of care. Additionally, WB-MRI seems a less histology-dependent functional imaging test than 18 F-FDG PET/CT and may be the imaging test of choice for staging of indolent NHLs with low 18 F-FDG avidity.
Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions
Khosla, Rahul; McLean, Anna W; Smith, Jessica A
2016-01-01
Background: Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. Methods: A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. Results: A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P < 0.0001). Conclusions: For pleural-based lesions the diagnostic accuracy of US guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure. PMID:27625440
Gandhi, Rohit; Lewis, Evan Cole; Evans, Jeanette W; Sell, Erick
2015-03-01
Headaches are a common problem in the pediatric population. In 2002, the American Academy of Neurology (AAN) developed guidelines on neuroimaging for patients presenting with headache. Our objective was to determine the frequency of computed tomographic (CT) scanning ordered by a range of medical practitioners for pediatric patients presenting with primary headache. A retrospective chart review was conducted at the Children's Hospital of Eastern Ontario (CHEO), a tertiary care centre in Ontario. One hundred fifty-one records of patients referred to the outpatient neurology clinic at CHEO with ''headache'' or ''migraine'' as the primary complaint from 2004 to 2009 were randomly selected. Ninety-nine patients with normal neurologic examinations were ultimately included. Thirty-four patients (34%; 95% CI 25-45) had undergone CT scanning. None of the 34 CT scans (0%; 95% CI 0-10) showed significant findings, and none changed the headache diagnosis or management. Eleven (32%) of the CT scans were ordered by CHEO neurologists, 15 (44%) by community physicians, and 8 (24%) by CHEO emergency physicians. A high proportion of children presenting with primary headaches and a normal neurologic examination undergo CT scanning, despite well-established AAN guidelines regarding neuroimaging. Most of these CT scans do not appear to alter diagnosis and management. A variety of non-evidencebased factors may be encouraging physicians to overinvestigate this population and, as a result, increasing the risk of adverse events due to radiation exposure. Implementing initiatives at a site-based level that promote the use of established guidelines before performing CT scanning in this population may be beneficial.
SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pham, R; Sun, B; Zhao, T
Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculatedmore » on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.« less
High energy x-ray phase contrast CT using glancing-angle grating interferometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarapata, A., E-mail: adrian.sarapata@tum.de; Stayman, J. W.; Siewerdsen, J. H.
Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code themore » authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.« less
Kolodziejczyk, Milena; Kepka, Lucyna; Dziuk, Miroslaw; Zawadzka, Anna; Szalus, Norbert; Gizewska, Agnieszka; Bujko, Krzysztof
2011-07-15
To evaluate prospectively how positron emission tomography (PET) information changes treatment plans for non-small-cell lung cancer (NSCLC) patients receiving or not receiving elective nodal irradiation (ENI). One hundred consecutive patients referred for curative radiotherapy were included in the study. Treatment plans were carried out with CT data sets only. For stage III patients, mediastinal ENI was planned. Then, patients underwent PET-CT for diagnostic/planning purposes. PET/CT was fused with the CT data for final planning. New targets were delineated. For stage III patients with minimal N disease (N0-N1, single N2), the ENI was omitted in the new plans. Patients were treated according to the PET-based volumes and plans. The gross tumor volume (GTV)/planning tumor volume (PTV) and doses for critical structures were compared for both data sets. The doses for areas of potential geographical misses derived with the CT data set alone were compared in patients with and without initially planned ENI. In the 75 patients for whom the decision about curative radiotherapy was maintained after PET/CT, there would have been 20 cases (27%) with potential geographical misses by using the CT data set alone. Among them, 13 patients would receive ENI; of those patients, only 2 patients had the PET-based PTV covered by 90% isodose by using the plans based on CT alone, and the mean of the minimum dose within the missed GTV was 55% of the prescribed dose, while for 7 patients without ENI, it was 10% (p = 0.006). The lung, heart, and esophageal doses were significantly lower for plans with ENI omission than for plans with ENI use based on CT alone. PET/CT should be incorporated in the planning of radiotherapy for NSCLC, even in the setting of ENI. However, if PET/CT is unavailable, ENI may to some extent compensate for an inadequate dose coverage resulting from diagnostic uncertainties. Copyright © 2011 Elsevier Inc. All rights reserved.
Redesigning Instruction through Web-based Course Authoring Tools.
ERIC Educational Resources Information Center
Dabbagh, Nada H.; Schmitt, Jeff
1998-01-01
Examines the pedagogical implications of redesigning instruction for Web-based delivery through a case study of an undergraduate computer science course. Initially designed for a traditional learning environment, this course transformed to a Web-based course using WebCT, a Web-based course authoring tool. Discusses the specific features of WebCT.…
Chapman, Cary B; Herrera, Mauricio F; Binenbaum, Gil; Schweppe, Michael; Staron, Ronald B; Feldman, Frieda; Rosenwasser, Melvin P
2003-09-01
The purpose of this prospective study was to determine the level of interobserver and intraobserver agreement among orthopedic surgeons and radiologists when computed tomography (CT) scans are used with plain radiographs to evaluate intertrochanteric fractures. In addition, the prognostic value of current classifications systems concerning quality of life was evaluated. Sixty-one patients who presented with intertrochanteric fractures received open reduction and internal fixation with compression hip screw. Three orthopedic surgeons and 2 radiologists independently classified the fractures according to 2 systems: Evans-Jensen and AO (Arbeitsgemeinschaft für Osteo-synthesefragen). Fractures were initially graded with plain radiographs and then again in conjunction with CT. Results were analyzed using the (kappa) kappa coefficient. The 36-item Short-Form Health Survey was administered at baseline, 3 months, and 1 year, and results were correlated with fracture grade. Mean kappa coefficients when comparing radiography alone with radiography and CT scan were 0.63 for the AO system and 0.59 for the Evans-Jensen system. Both represent "fair" agreements. Mean overall interobserver kappa coefficients were 0.67 for radiologists and 0.57 for orthopedic surgeons. Radiologists also had higher intraobserver kappa coefficients. No significant relationships were found between follow-up Short Form Health Survey results and intraoperative grading of fractures. When these classification schemes are compared, interobserver agreement does not appear to change dramatically when information from CT scans is added. This may suggest that (1) more data have been provided by CT with greater possibilities for misinterpretation and (2) these classification schemes may not be comprehensive in describing fracture pattern and displacement. Finally, both systems failed to provide any prognostic value.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakamura, Mitsuhiro; Shibuya, Keiko, E-mail: kei@kuhp.kyoto-u.ac.jp; Nakamura, Akira
2012-04-01
Purpose: To investigate the interfractional dose variations for intensity-modulated radiotherapy (RT) combined with breath-hold (BH) at end-exhalation (EE) for pancreatic cancer. Methods and Materials: A total of 10 consecutive patients with pancreatic cancer were enrolled. Each patient was fixed in the supine position on an individualized vacuum pillow with both arms raised. Computed tomography (CT) scans were performed before RT, and three additional scans were performed during the course of chemoradiotherapy using a conventional RT technique. The CT data were acquired under EE-BH conditions (BH-CT) using a visual feedback technique. The intensity-modulated RT plan, which used five 15-MV coplanar ports,more » was designed on the initial BH-CT set with a prescription dose of 39 Gy at 2.6 Gy/fraction. After rigid image registration between the initial and subsequent BH-CT scans, the dose distributions were recalculated on the subsequent BH-CT images under the same conditions as in planning. Changes in the dose-volume metrics of the gross tumor volume (GTV), clinical target volume (CTV = GTV + 5 mm), stomach, and duodenum were evaluated. Results: For the GTV and clinical target volume (CTV), the 95th percentile of the interfractional variations in the maximal dose, mean dose, dose covering 95% volume of the region of structure, and percentage of the volume covered by the 90% isodose line were within {+-}3%. Although the volume covered by the 39 Gy isodose line for the stomach and duodenum did not exceed 0.1 mL at planning, the volume covered by the 39 Gy isodose line for these structures was up to 11.4 cm{sup 3} and 1.8 cm{sup 3}, respectively. Conclusions: Despite variations in the gastrointestinal state and abdominal wall position at EE, the GTV and CTV were mostly ensured at the planned dose, with the exception of 1 patient. Compared with the duodenum, large variations in the stomach volume receiving high-dose radiation were observed, which might be beyond the negligible range in achieving dose escalation with intensity-modulated RT combined with BH at EE.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kanoun, Salim, E-mail: Salim.kanoun@gmail.com; LE2I UMR6306, Centre national de la recherche scientifique, Arts et Métiers, Université Bourgogne Franche-Comté, Dijon; MRI Unit, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon
Purpose: To compare the diagnostic performance of {sup 18}F-fluorocholine positron emission tomography/computed tomography (FCH-PET/CT), multiparametric prostate magnetic resonance imaging (mpMRI), and a combination of both techniques for the detection of local recurrence of prostate cancer initially treated by radiation therapy. Methods and Materials: This was a retrospective, single-institution study of 32 patients with suspected prostate cancer recurrence who underwent both FCH-PET/CT and 3T mpMRI within 3 months of one another for the detection of recurrence. All included patients had to be cleared for metastatic recurrence. The reference procedure was systematic 3-dimensional (3D)-transperineal prostate biopsy for the final assessment of local recurrence.more » Both imaging modalities were analyzed by 2 experienced readers blinded to clinical data. The analysis was made per-patient and per-segment using a 4-segment model. Results: The median prostate-specific antigen value at the time of imaging was 2.92 ng/mL. The mean prostate-specific antigen doubling time was 14 months. Of the 32 patients, 31 had a positive 3D-transperineal mapping biopsy for a local relapse. On a patient-based analysis, the detection rate was 71% (22 of 31) for mpMRI and 74% (23 of 31) for FCH-PET/CT. On a segment-based analysis, the sensitivity and specificity were, respectively, 32% and 87% for mpMRI, 34% and 87% for FCH-PET/CT, and 43% and 83% for the combined analysis of both techniques. Accuracy was 64%, 65%, and 66%, respectively. The interobserver agreement was κ = 0.92 for FCH-PET/CT and κ = 0.74 for mpMRI. Conclusions: Both mpMRI and FCH-PET/CT show limited sensitivity but good specificity for the detection of local cancer recurrence after radiation therapy, when compared with 3D-transperineal mapping biopsy. Prostate biopsy still seems to be mandatory to diagnose local relapse and select patients who could benefit from local salvage therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, Henal; Goyal, Sharad; Kim, Leonard, E-mail: kimlh@rutgers.edu
Several publications have recommended that patients undergoing whole-breast radiotherapy be resimulated for boost planning. The rationale for this is that the seroma may be smaller when compared with the initial simulation. However, the decision remains whether to use the earlier or later images to define an appropriate boost target volume. A patient undergoing whole-breast radiotherapy had new, injectable, temporary hydrogel fiducial markers placed 1 to 3 cm from the seroma at the time of initial simulation. The patient was resimulated 4.5 weeks later for conformal photon boost planning. Computed tomography (CT) scans acquired at the beginning and the end ofmore » whole-breast radiotherapy showed that shrinkage of the lumpectomy cavity was not matched by a corresponding reduction in the surrounding tissue volume, as demarcated by hydrogel markers. This observation called into question the usual interpretation of cavity shrinkage for boost target definition. For this patient, it was decided to define the boost target volume on the initial planning CT instead of the new CT.« less
Livingston, Michael H; Igric, Ana; Vogt, Kelly; Parry, Neil; Merritt, Neil H
2014-01-01
The purpose of this study was to determine the effective dose of radiation due to computed tomography (CT) scans in paediatric trauma patients at a level 1 Canadian paediatric trauma centre. We also explored the indications and actions taken as a result of these scans. We performed a retrospective review of paediatric trauma patients presenting to our centre from January 1, 2007 to December 31, 2008. All CT scans performed during the initial trauma resuscitation, hospital stay, and 6 months afterwards were included. Effective dose was calculated using the reported dose length product for each scan and conversion factors specific for body region and age of the patient. 157 paediatric trauma patients were identified during the 2-year study period. Mean Injury Severity Score was 22.5 (range 12-75). 133 patients received at least one CT scan. The mean number of scans per patient was 2.6 (range 0-16). Most scans resulted in no further action (56%) or additional imaging (32%). A decision to perform a procedure (2%), surgery (8%), or withdrawal of life support (2%) was less common. The average dose per patient was 13.5mSv, which is 4.5 times the background radiation compared to the general population. CT head was the most commonly performed type of scan and was most likely to be repeated. CT body, defined as a scan of the chest, abdomen, and/or pelvis, was associated with the highest effective dose. CT is a significant source of radiation in paediatric trauma patients. Clinicians should carefully consider the indications for each scan, especially when performing non-resuscitation scans. There is a need for evidence-based treatment algorithms to assist clinicians in selecting appropriate imaging for patients with severe multisystem trauma. Copyright © 2013 Elsevier Ltd. All rights reserved.
SU-F-I-47: Optimizing Protocols for Image Quality and Dose in Abdominal CT of Large Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, L; Yester, M
Purpose: Newer CT scanners are able to use scout views to adjust mA throughout the scan in order to achieve a given noise level. However, given constraints of radiologist preferences for kVp and rotation time, it may not be possible to achieve an acceptable noise level for large patients. A study was initiated to determine for which patients kVp and/or rotation time should be changed in order to achieve acceptable image quality. Methods: Patient scans were reviewed on two new Emergency Department scanners (Philips iCT) to identify patients over a large range of sizes. These iCTs were set with amore » limit of 500 mA to safeguard against a failure that might cause a CT scan to be (incorrectly) obtained at too-high mA. Scout views of these scans were assessed for both AP and LAT patient width and AP and LAT standard deviation in an ROI over the liver. Effective diameter and product of the scout standard deviations over the liver were both studied as possible metrics for identifying patients who would need kVp and/or rotation time changed. The mA used for the liver in the CT was compared to these metrics for those patients whose CT scans showed acceptable image quality. Results: Both effective diameter and product of the scout standard deviations over the liver result in similar predictions for which patients will require the kVp and/or rotation time to be changed to achieve an optimal combination of image quality and dose. Conclusion: Two mechanisms for CT technologists to determine based on scout characteristics what kVp, mA limit, and rotation time to use when DoseRight with our physicians’ preferred kVp and rotation time will not yield adequate image quality are described.« less
Krille, L; Dreger, S; Schindel, R; Albrecht, T; Asmussen, M; Barkhausen, J; Berthold, J D; Chavan, A; Claussen, C; Forsting, M; Gianicolo, E A L; Jablonka, K; Jahnen, A; Langer, M; Laniado, M; Lotz, J; Mentzel, H J; Queißer-Wahrendorf, A; Rompel, O; Schlick, I; Schneider, K; Schumacher, M; Seidenbusch, M; Spix, C; Spors, B; Staatz, G; Vogl, T; Wagner, J; Weisser, G; Zeeb, H; Blettner, M
2015-03-01
The aim of this cohort study was to assess the risk of developing cancer, specifically leukaemia, tumours of the central nervous system and lymphoma, before the age of 15 years in children previously exposed to computed tomography (CT) in Germany. Data for children with at least one CT between 1980 and 2010 were abstracted from 20 hospitals. Cancer cases occurring between 1980 and 2010 were identified by stochastic linkage with the German Childhood Cancer Registry (GCCR). For all cases and a sample of non-cases, radiology reports were reviewed to assess the underlying medical conditions at time of the CT. Cases were only included if diagnosis occurred at least 2 years after the first CT and no signs of cancer were recorded in the radiology reports. Standardised incidence ratios (SIR) using incidence rates from the general population were estimated. The cohort included information on 71,073 CT examinations in 44,584 children contributing 161,407 person-years at risk with 46 cases initially identified through linkage with the GCCR. Seven cases had to be excluded due to signs possibly suggestive of cancer at the time of first CT. Overall, more cancer cases were observed (O) than expected (E), but this was mainly driven by unexpected and possibly biased results for lymphomas. For leukaemia, the SIR (SIR = O/E) was 1.72 (95 % CI 0.89-3.01, O = 12), and for CNS tumours, the SIR was 1.35 (95 % CI 0.54-2.78, O = 7). Despite careful examination of the medical information, confounding by indication or reverse causation cannot be ruled out completely and may explain parts of the excess. Furthermore, the CT exposure may have been underestimated as only data from the participating clinics were available. This should be taken into account when interpreting risk estimates.
Engineer, Rakesh S; Podolsky, Seth R; Fertel, Baruch S; Grover, Purva; Jimenez, Heather; Simon, Erin L; Smalley, Courtney M
2018-05-15
The American College of Emergency Physicians embarked on the "Choosing Wisely" campaign to avoid computed tomographic (CT) scans in patients with minor head injury who are at low risk based on validated decision rules. We hypothesized that a Pediatric Mild Head Injury Care Path could be developed and implemented to reduce inappropriate CT utilization with support of a clinical decision support tool (CDST) and a structured parent discussion tool. A quality improvement project was initiated for 9 weeks to reduce inappropriate CT utilization through 5 interventions: (1) engagement of leadership, (2) provider education, (3) incorporation of a parent discussion tool to guide discussion during the emergency department (ED) visit between the parent and the provider, (4) CDST embedded in the electronic medical record, and (5) importation of data into the note to drive compliance. Patients prospectively were enrolled when providers at a pediatric and a freestanding ED entered data into the CDST for decision making. Rate of care path utilization and head CT reduction was determined for all patients with minor head injury based on International Classification of Diseases, Ninth Revision codes. Targets for care path utilization and head CT reduction were established a priori. Results were compared with baseline data collected from 2013. The CDST was used in 176 (77.5%) of 227 eligible patients. Twelve patients were excluded based on a priori criteria. Adherence to recommendations occurred in 162 (99%) of 164 patients. Head CT utilization was reduced from 62.7% to 22% (odds ratio, 0.17; 95% confidence interval, 0.12-0.24) where CDST was used by the provider. There were no missed traumatic brain injuries in our study group. A Pediatric Mild Head Injury Care Path can be implemented in a pediatric and freestanding ED, resulting in reduced head CT utilization and high levels of adherence to CDST recommendations.
Optimization of the protocols for the use of contrast agents in PET/CT studies.
Pelegrí Martínez, L; Kohan, A A; Vercher Conejero, J L
The introduction of PET/CT scanners in clinical practice in 1998 has improved care for oncologic patients throughout the clinical pathway, from the initial diagnosis of disease through the evaluation of the response to treatment to screening for possible recurrence. The CT component of a PET/CT study is used to correct the attenuation of PET studies; CT also provides anatomic information about the distribution of the radiotracer. CT is especially useful in situations where PET alone can lead to false positives and false negatives, and CT thereby improves the diagnostic performance of PET. The use of intravenous or oral contrast agents and optimal CT protocols have improved the detection and characterization of lesions. However, there are circumstances in which the systematic use of contrast agents is not justified. The standard acquisition in PET/CT scanners is the whole body protocol, but this can lead to artifacts due to the position of patients and respiratory movements between the CT and PET acquisitions. This article discusses these aspects from a constructive perspective with the aim of maximizing the diagnostic potential of PET/CT and providing better care for patients. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
2014-01-01
Background In equine practice, teeth corrections by means of motorized grinding systems are standard procedure. The heat resulting from that treatment may cause irreparable damage to the dental pulp. It has been shown that a 5.5°C temperature rise may cause severe destruction in pulp cells. Hence, the capability to continuously form secondary dentine is lost, and may lead, due to equine-typical occlusal tooth abrasion, to an opening of the pulp cavity. To obtain reliable data on the intra-pulp increase in temperature during corrective treatments, equine cheek teeth (CT) were modified in a way (occlusal surface smoothed, apical parts detached, pulp horns standardized) that had been qualified in own former published studies. All parameters influencing the grinding process were standardized (force applied, initial temperatures, dimensions of pulp horns, positioning of grinding disk, rotational speed). During grinding experiments, imitating real dental treatments, the time span for an intra-pulp temperature increase of 5.5°C was determined. Results The minimum time recorded for an intra-pulp temperature increase of 5.5°C was 38 s in mandibular CT (buccal grinding, 12,000 rpm) and 70 s in maxillary CT (flat occlusal grinding, 12,000 rpm). The data obtained showed that doubling the rotational speed of the disk results in halving the time span after which the critical intra-pulp temperature increase in maxillary CT is reached. For mandibular CT, the time span even drops by two thirds. Conclusion The use of standardized hypsodont CT enabled comparative studies of intra-pulp heating during the grinding of occlusal tooth surfaces using different tools and techniques. The anatomical structure of the natural vital hypsodont tooth must be kept in mind, so that the findings of this study do not create a deceptive sense of security with regard to the time-dependent heating of the native pulp. PMID:24559121
Ligand-assisted degradation of carbon tetrachloride by microscale zero-valent iron.
Zhang, Xianlan; Deng, Baolin; Guo, Jing; Wang, Yang; Lan, Yeqing
2011-04-01
Degradation of carbon tetrachloride (CT) by microscale zero-valent iron (ZVI) was investigated in batch systems with or without organic ligands (ethylenediaminetetraacetic acid (EDTA), citric acid, tartaric acid, malic acid and oxalic acid) at pHs from 3.5 to 7.5. The results demonstrated that at 25°C, the dechlorination of CT by microscale ZVI is slow in the absence of organic ligands, with a pseudo-first-order rate constant of 0.0217 h(-1) at pH 3.5 and being further dropped to 0.0052 h(-1) at pH 7.5. However, addition of organic ligands significantly enhanced the rates and the extents of CT removal, as indicated by the rate constant increases of 39, 31, 32, 28 and 18 times in the presence of EDTA, citric acid, tartaric acid, malic acid and oxalic acid, respectively, at pH 3.5 and 25°C. The effect of EDTA was most significant; the dechlorination of CT at an initial concentration of 20 mg l(-1) increased from 16.3% (no ligands) to 89.1% (with EDTA) at the end of 8h reaction. The enhanced CT degradation in the presence of organic ligands was primarily attributed to the elimination of a surface passivation layer of Fe(III) (hydr)oxides on the microscale ZVI through chelating of organic ligands with Fe(III), which maintained the exposure of active sites on ZVI surface to CT. Copyright © 2010 Elsevier Ltd. All rights reserved.
Boroffka, Susanne A E B; Verbruggen, Anne-Marie; Grinwis, Guy C M; Voorhout, George; Barthez, Paul Y
2007-03-01
To describe clinical, ultrasonographic, and computed tomographic (CT) features of confirmed neoplastic and nonneoplastic disease in dogs with unilateral orbital diseases, determine criteria to differentiate between the 2 conditions, and assess the relative value of ultrasonography and CT for the differential diagnosis of these 2 conditions. Prospective study. 29 dogs with unilateral neoplastic orbital disease and 16 dogs with unilateral nonneoplastic orbital disease. Clinical history and results of physical and ophthalmologic examinations were recorded. Ultrasonographic and CT images were evaluated, and discriminating factors were identified to differentiate neoplastic from nonneoplastic diseases. Diagnostic value of ultrasonography and CT was assessed. Dogs with neoplastic disease were significantly older; had clinical signs for a longer time before initial examination; had more progressive onset of clinical signs; and more frequently had protrusion of the nictitating membrane, fever, and anorexia. The most discriminating factor for both imaging modalities was delineation of the margins (odds ratio was 41.7 for ultrasonography and 45 for CT), with neoplastic lesions clearly delineated more often. Ultrasonographically, neoplastic lesions were more frequently hypoechoic and homogeneous, with indentation of the globe and bone involvement evident more frequently than for nonneoplastic lesions. Mineralization was detected only with neoplasia. Fluctuant fluid was seen more frequently in dogs with nonneoplastic disease. Computed tomography more frequently revealed extraorbital involvement. Diagnostic value was similar for both imaging modalities. Ultrasonography and CT are valuable imaging modalities to assist in differentiating neoplastic from nonneoplastic unilateral orbital disease in dogs.
Schwarzenböck, Sarah M; Eiber, Matthias; Kundt, Günther; Retz, Margitta; Sakretz, Monique; Kurth, Jens; Treiber, Uwe; Nawroth, Roman; Rummeny, Ernst J; Gschwend, Jürgen E; Schwaiger, Markus; Thalgott, Mark; Krause, Bernd J
2016-11-01
The aim of this study was to prospectively evaluate the value of [ 11 C] Choline PET/CT in monitoring early and late response to a standardized first-line docetaxel chemotherapy in castration refractory prostate cancer (mCRPC) patients. Thirty-two patients were referred for [ 11 C] Choline PET/CT before the start of docetaxel chemotherapy, after one and ten chemotherapy cycles (or - in case of discontinuation - after the last administered cycle) for therapy response assessment. [ 11 C] Choline uptake (SUV max , SUV mean ), CT derived Houndsfield units (HU max , HU mean ), and volume of bone, lung, and nodal metastases and local recurrence were measured semi-automatically at these timepoints. Change in SUV max , SUV mean , HU max , HU mean, and volume was assessed between PET 2 and 1 (early response assessment, ERA) and PET 3 and 1 (late response assessment, LRA) on a patient and lesion basis. Results of PET/CT were compared to clinically used RECIST 1.1 and clinical criteria based therapy response assessment including PSA for defining progressive disease (PD) and non-progressive disease (nPD), respectively. Relationships between changes of SUV max and SUV mean (early and late) and changes of PSA early and PSA late were evaluated. Prognostic value of initial SUV max and SUV mean was assessed. Statistical analyses were performed using SPSS. In the patient-based ERA and LRA there were no statistically significant differences in change of choline uptake, HU, and volume between PD and nPD applying RECIST or clinical response criteria. In the lesion-based ERA, decrease in choline uptake of bone metastases was even higher in PD (applying RECIST criteria), whereas in LRA the decrease was higher in nPD (applying clinical criteria). There were only significant correlations between change in choline uptake and PSA in ERA in PD, in LRA no significant correlations were discovered. Initial SUV max and SUV mean were statistically significantly higher in nPD (applying clinical criteria). There is no significant correlation between change in choline uptake in [ 11 C] Choline PET/CT and clinically routinely used objective response assessment during the early and late course of docetaxel chemotherapy. Therefore, [ 11 C] Choline PET/CT seems to be of limited use in therapy response assessment in standardized first-line chemotherapy in mCRPC patients.
Cho, Jinhan; Oh, Jongyeong; Kim, Dongwon; Cho, Junghyun; Kim, Sanghyun; Lee, Sangyun; Lee, Jihyun
2015-01-01
Objective: To investigate whether reduced radiation dose abdominal CT images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) compromise the depiction of clinically competent features when compared with the currently used routine radiation dose CT images reconstructed with ASIR. Methods: 27 consecutive patients (mean body mass index: 23.55 kg m−2 underwent CT of the abdomen at two time points. At the first time point, abdominal CT was scanned at 21.45 noise index levels of automatic current modulation at 120 kV. Images were reconstructed with 40% ASIR, the routine protocol of Dong-A University Hospital. At the second time point, follow-up scans were performed at 30 noise index levels. Images were reconstructed with filtered back projection (FBP), 40% ASIR, 30% ASIR-V, 50% ASIR-V and 70% ASIR-V for the reduced radiation dose. Both quantitative and qualitative analyses of image quality were conducted. The CT dose index was also recorded. Results: At the follow-up study, the mean dose reduction relative to the currently used common radiation dose was 35.37% (range: 19–49%). The overall subjective image quality and diagnostic acceptability of the 50% ASIR-V scores at the reduced radiation dose were nearly identical to those recorded when using the initial routine-dose CT with 40% ASIR. Subjective ratings of the qualitative analysis revealed that of all reduced radiation dose CT series reconstructed, 30% ASIR-V and 50% ASIR-V were associated with higher image quality with lower noise and artefacts as well as good sharpness when compared with 40% ASIR and FBP. However, the sharpness score at 70% ASIR-V was considered to be worse than that at 40% ASIR. Objective image noise for 50% ASIR-V was 34.24% and 46.34% which was lower than 40% ASIR and FBP. Conclusion: Abdominal CT images reconstructed with ASIR-V facilitate radiation dose reductions of to 35% when compared with the ASIR. Advances in knowledge: This study represents the first clinical research experiment to use ASIR-V, the newest version of iterative reconstruction. Use of the ASIR-V algorithm decreased image noise and increased image quality when compared with the ASIR and FBP methods. These results suggest that high-quality low-dose CT may represent a new clinical option. PMID:26234823
Raji, A R; Sardari, K; Mohammadi, H R
2008-06-01
The purpose of this study was to define the structures of the digits and hoof in Holstein dairy cattle by using computed tomography scan (CT scan). Transverse, sagittal and dorsoplantar CT images of two isolated cattle cadaver digits were obtained using a Siemens ARTX2 Somatom. The CT images were compared to corresponding frozen cross-sections. Relevant anatomical structures were identified and labelled at each level. The CT images provided anatomical detail of the digits and hoof in Holstein dairy cattle. Transversal images provided excellent depiction of anatomical structures when compared to corresponding frozen cross-sections. The information presented in this paper would serve as an initial reference to the evaluation of CT images of the digits and hoof in Holstein dairy cattle.
SU-F-T-26: A Study of the Consistency of Brachytherapy Treatments for Vaginal Cuff
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shojaei, M; Pella, S; Dumitru, N
2016-06-15
Purpose: To evaluate to treatment consistency over the total number of fractions when treatment what HDR brachytherapy using the ML cylinders. At the same time the dosimetric impact on the critical organs is monitored over the total number of fractions. Methods: A retrospective analysis of 10 patients treated with Cylinder applicators, from 2015–2016 were considered for this study. The CT scans of these patients, taken before each treatment were separately imported in to the treatment planning system and paired with the initial CT scan after completing the contouring. Two sets of CT images were fused together with respective to themore » applicator, using landmark registration. The doses of each plan were imported as well and a cumulative dosimetric analysis was made for bladder, bowels, and rectum and PTV. Results: No contour of any of the OAR was exactly similar when CT images were fused on each other. The PTV volumes vary from fraction to fraction. There was always a difference between the doses received by the OARs between treatments. The maximum dose varied between 5% and 30% in rectum and bladder. The minimum dose varied between 5% and 8% in rectum and bladder. The average dose varied between 15% and 20% in rectum and bladder. Deviation in placement were noticed between fractions. Conclusion: The variation in volumes of OARs and isodoses near the OARs, indicate that the estimated doses to OARs on the planning system may not be the same dose delivered to the patient in all the fractions. There are no major differences between the prescribed dose and the delivered dose over the total number of fractions. In some cases the critical organs will benefit if the consecutive plans will made after the CT scans will be registered with the initial scan and then planned.« less
Mimata, Yoshikuni; Murakami, Hideki; Sato, Kotaro; Suzuki, Yoshiaki
2014-01-01
Vertebral artery injury can be a complication of cervical spine injury. Although most cases are asymptomatic, the rare case progresses to severe neurological impairment and fatal outcomes. We experienced a case of bilateral cerebellar and brain stem infarction with fatal outcome resulting from vertebral artery injury associated with cervical spine trauma. A 69-year-old male was admitted to our hospital because of tetraplegia after falling down the stairs and hitting his head on the floor. Marked bony damage of the cervical spine was not apparent on radiographs and CT scans, so the injury was initially considered to be a cervical cord injury without bony damage. However, an intensity change in the intervertebral disc at C5/C6, and a ventral epidural hematoma were observed on MRI. A CT angiogram of the neck showed the right vertebral artery was completely occluded at the C4 level of the spine. Forty-eight hours after injury, the patient lapsed into drowsy consciousness. The cranial CT scan showed a massive low-density area in the bilateral cerebellar hemispheres and brain stem. Anticoagulation was initiated after a diagnosis of the right vertebral artery injury, but the patient developed bilateral cerebellar and brain stem infarction. The patient's brain herniation progressed and the patient died 52 h after injury. We considered that not only anticoagulation but also treatment for thrombosis would have been needed to prevent cranial embolism. We fully realize that early and appropriate treatment are essential to improve the treatment results, and constructing a medical system with a team of orthopedists, radiologists, and neurosurgeons is also very important.
Determinants of alveolar ridge preservation differ by anatomic location
Leblebicioglu, Binnaz; Salas, Mabel; Ort, Yirae; Johnson, Ashley; Yildiz, Vedat O.; Kim, Do-Gyoon; Agarwal, Sudha; Tatakis, Dimitris N.
2016-01-01
Aim To investigate and compare outcomes following alveolar ridge preservation (ARP) in posterior maxilla and mandible. Methods Twenty-four patients (54 ± 3 years) with single posterior tooth extraction were included. ARP was performed with freeze-dried bone allograft and collagen membrane. Clinical parameters were recorded at extraction and re-entry. Harvested bone cores were analysed by microcomputed tomography (micro-CT), histomorphometry and immunohistochemistry. Results In both jaws, ARP prevented ridge height loss, but ridge width was significantly reduced by approximately 2.5 mm. Healing time, initial clinical attachment loss and amount of keratinized tissue at extraction site were identified as determinants of ridge height outcome. Buccal plate thickness and tooth root length were identified as determinants of ridge width outcome. In addition, initial ridge width was positively correlated with ridge width loss. Micro-CT revealed greater mineralization per unit volume in new bone compared with existing bone in mandible (p < 0.001). Distributions of residual graft, new cellular bone and immature tissue were similar in both jaws. Conclusion Within the limitations of this study, the results indicate that in different anatomic locations different factors may determine ARP outcomes. Further studies are needed to better understand determinants of ARP outcomes. PMID:23432761
Gecse, Krisztina B; Lakatos, Péter L
2016-10-01
Biosimilars are biologic medicines that enter the market after a patent for an original reference product expires. The European Medicines Agency (EMA) developed a stringent legislation process for biosimilar monoclonal antibodies, whereby similarity to the reference medicinal product in terms of quality characteristics, biological activity, clinical safety and efficacy must be demonstrated. Biosimilar infliximab CT-P13 was the first biosimilar monoclonal antibody to receive EMA marketing authorization, and further biosimilar molecules are being developed. The phase I and III clinical trials were conducted in ankylosing spondylitis and rheumatoid arthritis, and the use of CT-P13 in inflammatory bowel disease (IBD) was extrapolated on the results of these trials. Medical professionals were initially concerned about the reversed engineering process, the novel legal framework and the lack of clinical data in IBD. Emerging real-world data have confirmed the similarities between CT-P13 and the reference product in terms of efficacy, safety and immunogenicity in IBD. The cost reduction represented by biosimilars promotes industry competition and improves treatment access with sustained quality of care. This article reviews the existing and emerging clinical data for CT-P13 and a future perspective on biosimilar use in IBD.
Yao, Jianhua; Burns, Joseph E.; Sanoria, Vic; Summers, Ronald M.
2017-01-01
Abstract. Bone metastases are a frequent occurrence with cancer, and early detection can guide the patient’s treatment regimen. Metastatic bone disease can present in density extremes as sclerotic (high density) and lytic (low density) or in a continuum with an admixture of both sclerotic and lytic components. We design a framework to detect and characterize the varying spectrum of presentation of spine metastasis on positron emission tomography/computed tomography (PET/CT) data. A technique is proposed to synthesize CT and PET images to enhance the lesion appearance for computer detection. A combination of watershed, graph cut, and level set algorithms is first run to obtain the initial detections. Detections are then sent to multiple classifiers for sclerotic, lytic, and mixed lesions. The system was tested on 44 cases with 225 sclerotic, 139 lytic, and 92 mixed lesions. The results showed that sensitivity (false positive per patient) was 0.81 (2.1), 0.81 (1.3), and 0.76 (2.1) for sclerotic, lytic, and mixed lesions, respectively. It also demonstrates that using PET/CT data significantly improves the computer aided detection performance over using CT alone. PMID:28612036
Almeida, Diogo F; Ruben, Rui B; Folgado, João; Fernandes, Paulo R; Audenaert, Emmanuel; Verhegghe, Benedict; De Beule, Matthieu
2016-12-01
Femur segmentation can be an important tool in orthopedic surgical planning. However, in order to overcome the need of an experienced user with extensive knowledge on the techniques, segmentation should be fully automatic. In this paper a new fully automatic femur segmentation method for CT images is presented. This method is also able to define automatically the medullary canal and performs well even in low resolution CT scans. Fully automatic femoral segmentation was performed adapting a template mesh of the femoral volume to medical images. In order to achieve this, an adaptation of the active shape model (ASM) technique based on the statistical shape model (SSM) and local appearance model (LAM) of the femur with a novel initialization method was used, to drive the template mesh deformation in order to fit the in-image femoral shape in a time effective approach. With the proposed method a 98% convergence rate was achieved. For high resolution CT images group the average error is less than 1mm. For the low resolution image group the results are also accurate and the average error is less than 1.5mm. The proposed segmentation pipeline is accurate, robust and completely user free. The method is robust to patient orientation, image artifacts and poorly defined edges. The results excelled even in CT images with a significant slice thickness, i.e., above 5mm. Medullary canal segmentation increases the geometric information that can be used in orthopedic surgical planning or in finite element analysis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Emaminejad, Nastaran; Wahi-Anwar, Muhammad; Hoffman, John; Kim, Grace H.; Brown, Matthew S.; McNitt-Gray, Michael
2018-02-01
Translation of radiomics into clinical practice requires confidence in its interpretations. This may be obtained via understanding and overcoming the limitations in current radiomic approaches. Currently there is a lack of standardization in radiomic feature extraction. In this study we examined a few factors that are potential sources of inconsistency in characterizing lung nodules, such as 1)different choices of parameters and algorithms in feature calculation, 2)two CT image dose levels, 3)different CT reconstruction algorithms (WFBP, denoised WFBP, and Iterative). We investigated the effect of variation of these factors on entropy textural feature of lung nodules. CT images of 19 lung nodules identified from our lung cancer screening program were identified by a CAD tool and contours provided. The radiomics features were extracted by calculating 36 GLCM based and 4 histogram based entropy features in addition to 2 intensity based features. A robustness index was calculated across different image acquisition parameters to illustrate the reproducibility of features. Most GLCM based and all histogram based entropy features were robust across two CT image dose levels. Denoising of images slightly improved robustness of some entropy features at WFBP. Iterative reconstruction resulted in improvement of robustness in a fewer times and caused more variation in entropy feature values and their robustness. Within different choices of parameters and algorithms texture features showed a wide range of variation, as much as 75% for individual nodules. Results indicate the need for harmonization of feature calculations and identification of optimum parameters and algorithms in a radiomics study.
Clements, Thomas W; Dunham, Michael; Kirkpatrick, Andrew; Rajakumar, Ruphus; Gratton, Carolyn; Lall, Rohan; McBeth, Paul; Ball, Chad G
2018-05-01
Evidence for repeat computed tomography (CT) in minor traumatic brain injury (mTBI) patients with intracranial pathology is scarce. The aim of this study was to investigate the utility of clinical cognitive assessment (COG) in defining the need for repeat imaging. COG performance was compared with findings on subsequent CT, and need for neurosurgery in mTBI patients (GCS 13-15 and positive CT findings). Of 152 patients, 65.8% received a COG (53.0% passed). Patients with passed COG underwent fewer repeat CT (43.4% vs. 78.7%; p = .001) and had shorter LOS (8.7 vs. 19.5; p < .05). Only 1 patient required neurosurgery after a passed COG. The negative predictive value of a normal COG was 90.6% (95%CI = 81.8%-95.4%). mTBI patients with an abnormal index CT who pass COG are less likely to undergo repeat CT head, and rarely require neurosurgery. The COG warrants further investigation to determine its role in omitting repeat head CT. Copyright © 2018 Elsevier Inc. All rights reserved.
SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qayyum, F; Armato, S; Straus, C
Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volumemore » of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology.« less
Kreitzer, Natalie; Lyons, Michael S; Hart, Kim; Lindsell, Cristopher J; Chung, Sora; Yick, Andrew; Bonomo, Jordan
2014-10-01
Emergency department (ED) management of mild traumatic brain injury (TBI) patients with any form of traumatic intracranial hemorrhage (ICH) is variable. Since 2000, our center's standard practice has been to obtain a repeat head computed tomography (CT) at least 6 hours after initial imaging. Patients are eligible for discharge if clinical and CT findings are stable. Whether this practice is safe is unknown. This study characterized clinical outcomes in mild TBI patients with acute traumatic ICH seen on initial ED neuroimaging. This retrospective cohort study included patients presenting to the ED with blunt mild TBI with Glasgow Coma Scale (GCS) scores of 14 or 15 and stable vital signs, during the period from January 2001 to January 2010. Patients with any ICH on initial head CT and repeat head CT within 24 hours were eligible. Cases were excluded for initial GCS < 14, injury > 24 hours old, pregnancy, concomitant nonminor injuries, and coagulopathy. A single investigator abstracted data from records using a standardized case report form and data dictionary. Primary endpoints included death, neurosurgical procedures, and for discharged patients, return to the ED within 7 days. Differences in proportions were computed with 95% confidence intervals (CIs). Of 1,011 patients who presented to the ED and had two head CTs within 24 hours, 323 (32%) met inclusion criteria. The median time between CT scans was 6 hours (interquartile range = 5 to 7 hours). A total of 153 (47%) patients had subarachnoid hemorrhage, 132 (41%) patients had subdural hemorrhage, 11 (3%) patients had epidural hemorrhage, 78 (24%) patients had cerebral contusions, and 59 (18%) patients had intraparenchymal hemorrhage. Four of 323 (1.2%, 95% CI = 0.3% to 3.2%) patients died within 2 weeks of injury. Three of the patients who died had been admitted from the ED on their initial visits, and one had been discharged home. There were 206 patients (64%) discharged from the ED, 28 (13.6%) of whom returned to the ED within 1 week. Of the 92 who were hospitalized, three (0.9%, 95% CI = 0.2% to 2.7%) required neurosurgical intervention. Discharge after a repeat head CT and brief period of observation in the ED allowed early discharge of a cohort of mild TBI patients with traumatic ICH without delayed adverse outcomes. Whether this justifies the cost and radiation exposure involved with this pattern of practice requires further study. © 2014 by the Society for Academic Emergency Medicine.
Garnon, Julien; Koch, Guillaume; Ramamurthy, Nitin; Caudrelier, Jean; Rao, Pramod; Tsoumakidou, Georgia; Cazzato, Roberto Luigi; Gangi, Afshin
2016-09-01
To review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures. Between May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57-75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment. Four pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1-4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2-3 months; one case could not be followed due to early post-procedural oncologic mortality. Percutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.
Kolodziejczyk, Milena; Bujko, Krzysztof; Michalski, Wojciech; Kepka, Lucyna
2012-07-01
Elective nodal irradiation (ENI) is not recommended in PET-CT-based radiotherapy for NSCLC despite a low level of evidence to support such guidelines. The aim of this investigation is to find out whether omitting ENI is safe. Sixty-seven patients treated within a frame of a previously published prospective trial of the value of PET-CT were included in the analysis. Seventeen (25%) patients received ENI due to higher initial nodal involvement and in the remaining 50 patients (75%) with N0-N1 or single N2 disease ENI was omitted. Isolated nodal failure (INF) was recorded if relapse occurred in the initially uninvolved regional lymph node without previous or simultaneous local recurrence regardless of the status of distant metastases. With a median follow-up of 32 months, the estimated 3-year overall survival was 42%, local progression-free interval was 55%, and distant metastases-free interval was 62%. Three patients developed INF; all had ENI omitted from treatment, giving a final result of three INFs in 50 (6%) patients treated without ENI. In this group of patients, the 3-year cause-specific cumulative incidence of INF was 6.4% (95% confidence interval: 0-17%). The omission of ENI appears to be not as safe as suggested by current recommendations. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Pandeeswaran, M.; Elango, K. P.
2010-05-01
Spectroscopic studies revealed that the interaction of cimetidine drug with electron acceptors iodine and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) resulted through the initial formation of ionic intermediate to charge transfer (CT) complex. The CT-complexes of the interactions have been characterized using UV-vis, 1H NMR, FT-IR and GC-MS techniques. The formation of triiodide ion, I 3-, is further confirmed by the observation of the characteristic bands in the far IR spectrum for non-linear I 3- ion with C s symmetry at 156 and 131 cm -1 assigned to νas(I-I) and νs(I-I) of the I-I bond and at 73 cm -1 due to bending δ(I 3-). The rate of formation of the CT-complexes has been measured and discussed as a function of relative permittivity of solvent and temperature. The influence of relative permittivity of the medium on the rate indicated that the intermediate is more polar than the reactants and this observation was further supported by spectral studies. Based on the spectroscopic results plausible mechanisms for the interaction of the drug with the chosen acceptors were proposed and discussed and the point of attachment of the multifunctional cimetidine drug with these acceptors during the formation of CT-complex has been established.
Romdhane, Zamen Ben; Tounsi, Hajer; Hadj-Sassi, Azza; Hadj-Taieb, Noomen; Gargouri, Ali
2013-01-01
The aim of the present study was to investigate pectinases production by CT1 mutant of Penicillium occitanis on glucose based media. Two main groups of pectinases were followed: lyases (pectin and pectate lyases) and hydrolases (polygalacturonases and polymethylgalacturonases). When cultivated in different liquid media, where either the starting glucose concentration or the nature of nitrogen sources used was varied, the CT1 mutant secreted either lyases or hydrolases. In fact, the pH of these various media seemed to correlate with the activity produced: The lyases were highly and exclusively produced at neutral or alkaline ambient pH, whereas hydrolases were highly produced on acidic ambient pH. Such conclusion was confirmed by following pectinase production in the same culture medium (with the same glucose concentration and the same nitrogen source) set at two initial pH of 4 and 7. Altogether, these results suggest that the pectinases control by PacC signaling pathway of P. occitanis should resemble to that of Aspergillus and its ability to "activate the expression of alkaline-expressed genes and repress acid-expressed genes" remains intact in the CT1 over-producing and constitutive strain. Enzymes produced at acidic pH (hydrolases) and at neutral pH (lyases) were applied in the hydrolysis of orange peel and gave results comparable to commercial enzymes.
Negre, T; Faure, A; Andre, M; Daniel, L; Coulange, C; Lechevallier, E
2011-11-01
Angiomyolipoma is the most frequent benign renal solid tumor. Because of the lack of fat component on the CT scan, diagnosis of this tumor is hard and can require percutaneous biopsy of unknown renal tumor. The follow-up of the poor fat CT scan component AML (PFCT AML) is uncertain. Five hundred percutaneous renal biopsy under tomodenstitometry have been realised between 1998 and 2008. There was 41 PFCT AML on the 500 biopsy. By definition, a PFCT AML is an AML where the diagnosis is done on a percutaneous biopsy but where there was no fat component on the first CT scan. We studied and compared clinical, tomodensitometric and histologic parameters of these 41 patients (mean age: 56, 9±11.04; sexe rate M/F: 6/35) where renal AML was diagnosed on percutaneous renal biopsy but without fat component on CT scan. Average size was 26.44±14.68mm. We phone-called 16 patients for the long-term follow-up. Average follow-up was 41±28.3 months. For four patients on 16, initial diagnosis was done in front of local symptoms, for one of the 16 diagnosis was done in front of general symptoms, for one of the diagnosis was done during Bourneville tuberous sclerosis evolution and 10 of the 16 was done fortuitously. After review of the initial CT scan, fat density was found on 24% of them. Ten percent was epithelioid angiomyolipoma. Four renal biopsy on 41 (10%) was epithelioid AML. No epithelioid AML had fat component after the second look of the CT scan. Among the 16 patients who were phone-called, three (19%) underwent a complication. Two had abdominal pain and was treated medically. Initial sizes were 26 and 30mm. Only one patient must be operated by radical nephrectomy for acute hemorrhage. Initial size was 45mm. No neoplasic degeneration was identified for those 16 patients. In our study, the PFCT AML rate was 8.2%. In 25% cases, CT scan read-through shown a fat component and could help for the diagnosis. PFCT AML evolution seems to be the same as a classic AML. Conservative treatment had a good covering because there was no death and no malignant evolution. However, we found 10% of epithelioid angiomyolipoma in which malignant risk is high. PFCT AML diagnosed on renal percutaneous biopsy of unknown renal tumor requires the same management than the classic AML. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Increasing the automation of a 2D-3D registration system.
Varnavas, Andreas; Carrell, Tom; Penney, Graeme
2013-02-01
Routine clinical use of 2D-3D registration algorithms for Image Guided Surgery remains limited. A key aspect for routine clinical use of this technology is its degree of automation, i.e., the amount of necessary knowledgeable interaction between the clinicians and the registration system. Current image-based registration approaches usually require knowledgeable manual interaction during two stages: for initial pose estimation and for verification of produced results. We propose four novel techniques, particularly suited to vertebra-based registration systems, which can significantly automate both of the above stages. Two of these techniques are based upon the intraoperative "insertion" of a virtual fiducial marker into the preoperative data. The remaining two techniques use the final registration similarity value between multiple CT vertebrae and a single fluoroscopy vertebra. The proposed methods were evaluated with data from 31 operations (31 CT scans, 419 fluoroscopy images). Results show these methods can remove the need for manual vertebra identification during initial pose estimation, and were also very effective for result verification, producing a combined true positive rate of 100% and false positive rate equal to zero. This large decrease in required knowledgeable interaction is an important contribution aiming to enable more widespread use of 2D-3D registration technology.
Putzer, D; Gabriel, M; Kendler, D; Henninger, B; Knoflach, M; Kroiss, A; Vonguggenberg, E; Warwitz, B; Virgolini, I J
2010-02-01
(68)Ga-DOTA-Tyr3-octreotide positron emission tomography ((68)Ga-DOTA-TOC PET) and (18)F-fluoro-L-dihydroxyphenylalanine PET ((18)F-DOPA PET) are emerging modalities for imaging of neuroendocrine tumors. This study reports our initial experiences with these two PET modalities on initial diagnosis, staging and restaging in NET patients. Fifteen patients with NET underwent both (68)Ga-DOTA-TOC and (18)F-DOPA PET as well as computed tomography (CT). Image findings were compared on a patient-basis (pathological uptake: yes/no) as well as on a lesion-basis. Contrast-enhanced CT and histological follow-up served as gold standard. Furthermore, imaging results were matched with tumor marker levels and quantitative tracer uptake by the tumor lesions. When comparing (68)Ga-DOTA-TOC and (18)F-DOPA PET, each modality showed a sensitivity of 64% and a specificity of 100% on a patient-based analysis. (68)Ga-DOTA-TOC PET and (18)F-DOPA PET showed equal findings in 7 out of 15 patients and disagreement in 8 patients. (68)Ga-DOTA-TOC revealed more metastases than (18)F-DOPA PET in 6 patients, while (18)F-DOPA PET detected more metastases than (68)Ga-DOTA-TOC in 4 patients. By (68)Ga-DOTA-TOC PET, 208 malignant lesions were detected, while by (18)F-DOPA only 86 lesions were found, and in CT 124, respectively. (68)Ga-DOTA-TOC and (18)F-DOPA PET are useful tools in the detection and staging of NET lesions. Our initial results allow the conclusion that (68)Ga-DOTA-TOC PET may have a stronger clinical impact in NET patients, as it does not only offer diagnostic information, but is decisive for the further treatment management, i. e. PRRT, as well.
Horn, Paul R; Head-Gordon, Martin
2016-02-28
In energy decomposition analysis (EDA) of intermolecular interactions calculated via density functional theory, the initial supersystem wavefunction defines the so-called "frozen energy" including contributions such as permanent electrostatics, steric repulsions, and dispersion. This work explores the consequences of the choices that must be made to define the frozen energy. The critical choice is whether the energy should be minimized subject to the constraint of fixed density. Numerical results for Ne2, (H2O)2, BH3-NH3, and ethane dissociation show that there can be a large energy lowering associated with constant density orbital relaxation. By far the most important contribution is constant density inter-fragment relaxation, corresponding to charge transfer (CT). This is unwanted in an EDA that attempts to separate CT effects, but it may be useful in other contexts such as force field development. An algorithm is presented for minimizing single determinant energies at constant density both with and without CT by employing a penalty function that approximately enforces the density constraint.
Malignant external otitis: early scintigraphic detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strashun, A.M.; Nejatheim, M.; Goldsmith, S.J.
1984-02-01
Pseudomonas otitis externa in elderly diabetics may extend aggressively to adjacent bone, cranial nerves, meninges, and vessels, leading to a clinical diagnosis of ''malignant'' external otitis. Early diagnosis is necessary for successful treatment. This study compares the findings of initial radiographs, thin-section tomography of temporal bone, CT scans of head and neck, technetium-99m methylene diphosphonate (MDP) and gallium-67 citrate scintigraphy, and single-photon emission computed tomography (SPECT) for detection of temporal bone osteomylitis in ten patients fulfilling the clinical diagnostic criteria of malignant external otitis. Skull radiographs were negative in all of the eight patients studied. Thin-section tomography was positive inmore » one of the seven patients studied using this modality. CT scanning suggested osteomyelitis in three of nine patients. Both Tc-99m and Ga-67 citrate scintigraphy were positive in 10 of 10 patients. These results suggest that technetium and gallium scintigraphy are more sensitive than radiographs and CT scans for early detection of malignant external otitis.« less
Castro, Alfonso; Boveda, Carmen; Arcay, Bernardino; Sanjurjo, Pedro
2016-01-01
The detection of pulmonary nodules is one of the most studied problems in the field of medical image analysis due to the great difficulty in the early detection of such nodules and their social impact. The traditional approach involves the development of a multistage CAD system capable of informing the radiologist of the presence or absence of nodules. One stage in such systems is the detection of ROI (regions of interest) that may be nodules in order to reduce the space of the problem. This paper evaluates fuzzy clustering algorithms that employ different classification strategies to achieve this goal. After characterising these algorithms, the authors propose a new algorithm and different variations to improve the results obtained initially. Finally it is shown as the most recent developments in fuzzy clustering are able to detect regions that may be nodules in CT studies. The algorithms were evaluated using helical thoracic CT scans obtained from the database of the LIDC (Lung Image Database Consortium). PMID:27517049
Storto, Giovanni; Gallicchio, Rosj; Pellegrino, Teresa; Nardelli, Anna; De Luca, Serena; Capacchione, Daniela; Sirignano, Cesare; Pace, Leonardo
2013-05-01
This study evaluated the diagnostic impact of using skeletal (18)F-fluoride PET/CT on patients with painful bone metastases to schedule an early palliative radionuclide treatment. The skeletal involvement from prostate cancer metastases was assessed by both (99m)Tc-diphosphonate bone scan (BS) and (18)F-fluoride PET/CT within four weeks in 24 patients (67.7 ± 5.1 years) suffering from a borderline degree of bone pain for which radionuclide palliation was not shortly planned for administration. The BS and (18)F-fluoride PET/CT results were compared, assessing the number and extension of the skeletal sites involved. Afterward, the patients were randomly assigned either to the study group (N=12) receiving radionuclide therapy (Samarium-153 EDTMP) or to the control group (N=12) not receiving radionuclide therapy. The short-term results from the radionuclide palliation group (evaluated with a visual analogue scale) were compared with the controls. Overall, at BS, 7.6 ± 1.4 sites were considered metastatic, involving at least 5 ± 1 body regions. At (18)F-fluoride PET/CT, 116 ± 19 sites presented metastatic involvement with 12/12 body regions concerned. No differences were found in regards to either the number of metastatic sites or regions at both BS and (18)F-fluoride PET/CT between the study group and controls (p=ns). At CT, 88 blastic metastases were identified, whereas 110 were mainly lytic. Most of mainly lytic lesions were not detectable at BS. The reduction in total discomfort and bone pain in the study group was significantly greater than in the controls (p<0.0001). Sm-153 EDTMP therapy should be considered for patients with early bone pain from prostate cancer even if their BS only indicates a few metastases before the initiation of a severe pain syndrome. (18)F-fluoride PET/CT may be helpful in deciding if the implementation of bone pain palliation using bone-seeking radionuclides at pain onset is necessary. Copyright © 2013 Elsevier Inc. All rights reserved.
Exploring Issues about Computational Thinking in Higher Education
ERIC Educational Resources Information Center
Czerkawski, Betul C.; Lyman, Eugene W., III
2015-01-01
The term computational thinking (CT) has been in academic discourse for decades, but gained new currency in 2006, when Jeanette Wing used it to describe a set of thinking skills that students in all fields may require in order to succeed. Wing's initial article and subsequent writings on CT have been broadly influential; experts in…
Tangential scanning of hardwood logs: developing an industrial computer tomography scanner
Nand K. Gupta; Daniel L. Schmoldt; Bruce Isaacson
1999-01-01
It is generally believed that noninvasive scanning of hardwood logs such as computer tomography (CT) scanning prior to initial breakdown will greatly improve the processing of logs into lumber. This belief, however, has not translated into rapid development and widespread installation of industrial CT scanners for log processing. The roadblock has been more operational...
CT Imaging, Data Reduction, and Visualization of Hardwood Logs
Daniel L. Schmoldt
1996-01-01
Computer tomography (CT) is a mathematical technique that, combined with noninvasive scanning such as x-ray imaging, has become a powerful tool to nondestructively test materials prior to use or to evaluate materials prior to processing. In the current context, hardwood lumber processing can benefit greatly by knowing what a log looks like prior to initial breakdown....
NASA Astrophysics Data System (ADS)
Sinclair Yemini, Francis; Chenu, Claire; Monga, Olivier; Vieuble Gonond, Laure; Juarez, Sabrina; Pihneiro, Marc; otten, Wilfred; Garnier, Patricia
2014-05-01
Contaminant degradation by microorganisms is very variable in soils because of the very heterogeneous spatial relationship of contaminant/degraders. Repacked Soil columns were carried out to study the degradation of 2,4D pesticide labelled with C14 for different scenarios of microorganisms and pesticide initial location. Measurements of global C14-CO2 emission and C14 distribution in the soil column showed that the initial location play a crucial rule on the dissipation of the pollutant. Experiments were simulated using a 3D model able to model microbial degradation and substrate diffusion between aggregates by considering explicitly the 3D structure of soil from CT images. The initial version of the model (Monga et al., 2008) was improved in order to simulate diffusion in samples of large size. Partial differential equations were implemented using freefem++ solver. The model simulates properly the dynamics of 2,4D in the column for the different initial situations. CT images of the same soil but using undisturbed structure instead of repacked aggregates were also carried out. Significant differences of the simulated results were observed between the repacked and the undisturbed soil. The conclusion of our work is that the heterogeneity of the soil structure and location of pollutants and decomposers has a very strong influence on the dissipation of pollutants.
Feng, Bai-Sui; Chen, Xiao; He, Shao-Heng; Zheng, Peng-Yuan; Foster, Jane; Xing, Zhou; Bienenstock, John; Yang, Ping-Chang
2008-07-01
Recent reports indicate that dendritic cell (DC)-derived T-cell immunoglobulin and mucin domain molecule (TIM)-4 plays an important role in the initiation of T(H)2 polarization. This study aims to elucidate the mechanisms of peanut allergy mediated by microbial products and DCs and the relationship between peanut allergy and TIM4. Mouse bone marrow-derived DCs (BMDCs) were generated and exposed to cholera toxin (CT) or/and peanut extract (PE) for 24 hours and then adoptively transferred to naive mice. After re-exposure to specific antigen PE, the mice were killed; intestinal allergic status was determined. Increased expression of TIM4 and costimulatory molecules was detected in BMDCs after concurrent exposure to CT and PE. Adoptively transferred CT/PE-conditioned BMDCs resulted in the increases in serum PE-specific IgE and skewed T(H)2 polarization in the intestine. Oral challenge with specific antigen PE induced mast cell activation in the intestine. Treating with Toll-like receptor 4 small interfering RNA abolished increased expression of TIM4 and costimulatory molecules by BMDCs. Pretreatment with anti-TIM1 or anti-TIM4 antibody abolished PE-specific T(H)2 polarization and allergy in the intestine. Concurrent exposure to microbial product CT and food antigen PE increases TIM4 expression in DCs and promotes DC maturation, which plays an important role in the initiation of PE-specific T(H)2 polarization and allergy in the intestine. Modulation of TIM4 production in DCs represents a novel therapeutic approach for the treatment of peanut allergy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang Meijuan; Jiang Yu; State Key Laboratory of Biotherapy, West China Hospital, Medical School, Sichuan University, Chengdu
Purpose: To investigate the role of early or up-front radiotherapy (RT), the optimal RT dose required to achieve appropriate treatment outcome and prognostic factors for patients with localized extranodal NK/T-cell lymphoma, nasal-type, in the upper aerodigestive tract. Methods and Materials: Eighty-two patients were reviewed. Eight patients were treated with chemotherapy (CT) alone, 9 patients received RT alone, and 65 patients were given combined modality treatment of CT and RT (CMT). Of those 74 patients receiving RT, 31 patients were given up-front RT, whereas CT was the initial therapy for 43 patients and 41 of those 43 patients received early RT.more » Results: Five-year overall survival (OS) and disease-free survival (DFS) were 52.3% and 39.2%, respectively. RT was the only independent prognostic factor for both OS and DFS at both the univariate and multivariate level. The 5-year OS and DFS were better in patients receiving {>=}54 Gy of RT as compared with that of <54 Gy (5-year OS 75.5% vs. 46.1%, p = 0.019; 5-year DFS 60.3% vs. 33.4%, p = 0.004). Up-front RT presented better survival in Stage I patients when compared with that of initial CT followed by early RT (5-year OS 90.0% vs. 48.9%, p = 0.012; 5-year DFS 78.7% vs. 39.9%, p = 0.021). Conclusion: Early or up-front RT had an essential role in improved OS and DFS in patients with localized extranodal NK/T-cell lymphoma, nasal-type, in the upper aerodigestive tract. The recommended tumor dose was at least 54 Gy. Up-front RT may yield more benefits on survival in patients with Stage I disease.« less
Hwang, Jae Pil; Lim, Ilhan; Kong, Chang-Bae; Jeon, Dae Geun; Byun, Byung Hyun; Kim, Byung Il; Choi, Chang Woon; Lim, Sang Moo
2016-01-01
Aim The aim of this retrospective study was to determine whether glucose metabolism assessed by using Fluorine-18 (F-18) fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) provides prognostic information independent of established prognostic factors in patients with Ewing sarcoma. Methods We retrospectively reviewed the medical records of 34 patients (men, 19; women, 15; mean age, 14.5 ± 9.7 years) with pathologically proven Ewing sarcoma. They had undergone F-18 FDG PET/CT as part of a pretreatment workup between September 2006 and April 2012. In this analysis, patients were classified by age, sex, initial location, size, and maximum standardized uptake value (SUVmax). The relationship between FDG uptake and survival was analyzed using the Kaplan-Meier method with the log-rank test and Cox’s proportional hazards regression model. Results The median survival time for all 34 subjects was 999 days and the median SUV by using PET/CT was 5.8 (range, 2–18.1). Patients with a SUVmax ≤ 5.8 survived significantly longer than those with a SUVmax > 5.8 (median survival time, 1265 vs. 656 days; p = 0.002). Survival was also found to be significantly related to age (p = 0.024), size (p = 0.03), and initial tumor location (p = 0.036). Multivariate analysis revealed that a higher SUVmax (p = 0.003; confidence interval [CI], 3.63–508.26; hazard ratio [HR], 42.98), older age (p = 0.023; CI, 1.34–54.80; HR, 8.59), and higher stage (p = 0.03; CI, 1.21–43.95; HR, 7.3) were associated with worse overall survival. Conclusions SUVmax measured by pretreatment F-18-FDG PET/CT can predict overall survival in patients with Ewing sarcoma. PMID:27100297
Nuechterlein, Keith H.; Ventura, Joseph; McEwen, Sarah C.; Gretchen-Doorly, Denise; Vinogradov, Sophia; Subotnik, Kenneth L.
2016-01-01
Cognitive training (CT) and aerobic exercise have separately shown promise for improving cognitive deficits in schizophrenia. Aerobic exercise releases brain-derived neurotrophic factor, which promotes synaptic plasticity and neurogenesis. Thus, aerobic exercise provides a neurotrophic platform for neuroplasticity-based CT. The combination of aerobic exercise and CT may yield more robust effects than CT alone, particularly in the initial course of schizophrenia. In a pilot study, 7 patients with a recent onset of schizophrenia were assigned to Cognitive Training & Exercise (CT&E) and 9 to CT alone for a 10-week period. Posit Science programs were used for CT. Neurocognitive training focused on tuning neural circuits related to perceptual processing and verbal learning and memory. Social cognitive training used the same learning principles with social and affective stimuli. Both groups participated in these training sessions 2d/wk, 2h/d. The CT&E group also participated in an aerobic conditioning program for 30 minutes at our clinic 2d/wk and at home 2d/wk. The effect size for improvement in the MATRICS Consensus Cognitive Battery Overall Composite score for CT&E patients relative to CT patients was large. Functional outcome, particularly independent living skills, also tended to improve more in the CT&E than in the CT group. Muscular endurance, cardiovascular fitness, and diastolic blood pressure also showed relative improvement in the CT&E compared to the CT group. These encouraging pilot study findings support the promise of combining CT and aerobic exercise to improve the early course of schizophrenia. PMID:27460618
Validation of a deformable image registration technique for cone beam CT-based dose verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moteabbed, M., E-mail: mmoteabbed@partners.org; Sharp, G. C.; Wang, Y.
2015-01-15
Purpose: As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modulated radiotherapy (IMRT) dose based on multimodal deformable image registration (DIR) for prostate treatments. Methods: A pelvic phantom was scanned with CT and cone-beam computed tomography (CBCT). Both images were digitally deformed using two realistic patient-based deformation fields. The original CT was then registered to the deformed CBCT resulting in a secondary deformedmore » CT. The registration quality was assessed as the ability of the DIR method to recover the artificially induced deformations. The primary and secondary deformed CT images as well as vector fields were compared to evaluate the efficacy of the registration method and it’s suitability to be used for dose calculation. PLASTIMATCH, a free and open source software was used for deformable image registration. A B-spline algorithm with optimized parameters was used to achieve the best registration quality. Geometric image evaluation was performed through voxel-based Hounsfield unit (HU) and vector field comparison. For dosimetric evaluation, IMRT treatment plans were created and optimized on the original CT image and recomputed on the two warped images to be compared. The dose volume histograms were compared for the warped structures that were identical in both warped images. This procedure was repeated for the phantom with full, half full, and empty bladder. Results: The results indicated mean HU differences of up to 120 between registered and ground-truth deformed CT images. However, when the CBCT intensities were calibrated using a region of interest (ROI)-based calibration curve, these differences were reduced by up to 60%. Similarly, the mean differences in average vector field lengths decreased from 10.1 to 2.5 mm when CBCT was calibrated prior to registration. The results showed no dependence on the level of bladder filling. In comparison with the dose calculated on the primary deformed CT, differences in mean dose averaged over all organs were 0.2% and 3.9% for dose calculated on the secondary deformed CT with and without CBCT calibration, respectively, and 0.5% for dose calculated directly on the calibrated CBCT, for the full-bladder scenario. Gamma analysis for the distance to agreement of 2 mm and 2% of prescribed dose indicated a pass rate of 100% for both cases involving calibrated CBCT and on average 86% without CBCT calibration. Conclusions: Using deformable registration on the planning CT images to evaluate the IMRT dose based on daily CBCTs was found feasible. The proposed method will provide an accurate dose distribution using planning CT and pretreatment CBCT data, avoiding the additional uncertainties introduced by CBCT inhomogeneity and artifacts. This is a necessary initial step toward future image-guided adaptive radiotherapy of the prostate.« less
Djan, Igor; Petrović, Borislava; Erak, Marko; Nikolić, Ivan; Lucić, Silvija
2013-08-01
Development of imaging techniques, computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET), made great impact on radiotherapy treatment planning by improving the localization of target volumes. Improved localization allows better local control of tumor volumes, but also minimizes geographical misses. Mutual information is obtained by registration and fusion of images achieved manually or automatically. The aim of this study was to validate the CT-MRI image fusion method and compare delineation obtained by CT versus CT-MRI image fusion. The image fusion software (XIO CMS 4.50.0) was applied to delineate 16 patients. The patients were scanned on CT and MRI in the treatment position within an immobilization device before the initial treatment. The gross tumor volume (GTV) and clinical target volume (CTV) were delineated on CT alone and on CT+MRI images consecutively and image fusion was obtained. Image fusion showed that CTV delineated on a CT image study set is mainly inadequate for treatment planning, in comparison with CTV delineated on CT-MRI fused image study set. Fusion of different modalities enables the most accurate target volume delineation. This study shows that registration and image fusion allows precise target localization in terms of GTV and CTV and local disease control.
[Secondary Splenic Rupture after Initially Inconspicuous CAT Scan].
Prokop, A; Koll, S; Chmielnicki, M
2016-04-01
Splenic injuries occur in 1-5 % of blunt abdominal trauma cases. After initial haemorrhagic compression, secondary delayed spleen rupture can occur with a latency of one day to a month or longer. Mortality is then up to 15 %. The spleen injury is almost always recognisable on CT or ultrasound. In one case from our clinic, secondary splenic rupture occurred in a patient after discharge from hospitalisation, even though the initial CT and ultrasound were unremarkable. The patient survived, and underwent emergent splenectomy 8 days after the trauma. An expert review of the case identified no errors in treatment. No case of secondary splenic rupture after initially unremarkable diagnostic studies and clinical course has previously been published. Secondary splenic rupture has a high mortality rate. Patients should be advised of potential complications after hospital discharge, and should return to the hospital immediately in case of symptoms. Georg Thieme Verlag KG Stuttgart · New York.
Role of 18F-fluoride PET/CT in the assessment of multiple myeloma: initial experience.
Nishiyama, Yuji; Tateishi, Ukihide; Shizukuishi, Kazuya; Shishikura, Ayako; Yamazaki, Etsuko; Shibata, Hiroto; Yoneyama, Tomohiro; Ishigatsubo, Yoshiaki; Inoue, Tomio
2013-01-01
The aim of this study was to report our early experience with (18)F-fluoride PET/CT for detecting lesions and evaluate the usefulness of this modality in the assessment of multiple myeloma (MM). (18)F-fluoride PET/CT and (99m)Tc-MDP bone scintigraphy (BS) studies from 7 myeloma patients (4 male and 3 female, mean age 55 years) diagnosed according to standard criteria were reviewed retrospectively. Two reviewers visually and quantitatively analyzed the images and recorded their findings after reaching a consensus. Diagnostic certainty regarding the presence or absence of myeloma lesions was evaluated according to the reference standard consisting of whole-body magnetic resonance imaging and whole-body X-ray. A total of 93 affected areas were definite according to the reference standard. Of these, 83 affected areas (89 %) were identified on (18)F-fluoride PET/CT, whereas 54 affected areas (58 %) were found on BS. Mean SUVmax in the affected areas was 9.8 ± 3.2 (standard deviation) ranging from 5.0 to 21.2. A total of s17 lesions with bone fracture were also detected by (18)F-fluoride PET/CT and 2 lesions (12 %) were negative on BS. Our result showed that (18)F-fluoride PET was a possible modality to detect areas of lesions in patients with MM.
Itazawa, Tomoko; Tamaki, Yukihisa; Komiyama, Takafumi; Nishimura, Yasumasa; Nakayama, Yuko; Ito, Hiroyuki; Ohde, Yasuhisa; Kusumoto, Masahiko; Sakai, Shuji; Suzuki, Kenji; Watanabe, Hirokazu; Asamura, Hisao
2017-01-01
The purpose of this study was to develop a consensus-based computed tomographic (CT) atlas that defines lymph node stations in radiotherapy for lung cancer based on the lymph node map of the International Association for the Study of Lung Cancer (IASLC). A project group in the Japanese Radiation Oncology Study Group (JROSG) initially prepared a draft of the atlas in which lymph node Stations 1–11 were illustrated on axial CT images. Subsequently, a joint committee of the Japan Lung Cancer Society (JLCS) and the Japanese Society for Radiation Oncology (JASTRO) was formulated to revise this draft. The committee consisted of four radiation oncologists, four thoracic surgeons and three thoracic radiologists. The draft prepared by the JROSG project group was intensively reviewed and discussed at four meetings of the committee over several months. Finally, we proposed definitions for the regional lymph node stations and the consensus-based CT atlas. This atlas was approved by the Board of Directors of JLCS and JASTRO. This resulted in the first official CT atlas for defining regional lymph node stations in radiotherapy for lung cancer authorized by the JLCS and JASTRO. In conclusion, the JLCS–JASTRO consensus-based CT atlas, which conforms to the IASLC lymph node map, was established. PMID:27609192
Improving ultrasound for appendicitis through standardized reporting of secondary signs.
Partain, Kristin N; Patel, Adarsh U; Travers, Curtis; Short, Heather L; Braithwaite, Kiery; Loewen, Jonathan; Heiss, Kurt F; Raval, Mehul V
2017-08-01
Our aim was to implement a standardized US report that included secondary signs of appendicitis (SS) to facilitate accurate diagnosis of appendicitis and decrease the use of computed tomography (CT) and admissions for observation. A multidisciplinary team implemented a quality improvement (QI) intervention in the form of a standardized US report and provided stakeholders with monthly feedback. Outcomes including report compliance, CT use, and observation admissions were compared pretemplate and posttemplate. We identified 387 patients in the pretemplate period and 483 patients in the posttemplate period. In the posttemplate period, the reporting of SS increased from 5.4% to 79.5% (p<0.001). Despite lower rates of appendix visualization (43.9% to 32.7%, p<0.001) with US, overall CT use (8.5% vs 7.0%, p=0.41) and the negative appendectomy rate remained stable (1.0% vs 1.0%, p=1.0). CT utilization for patients with an equivocal ultrasound and SS present decreased (36.4% vs 8.9%, p=0.002) and admissions for observations decreased (21.5% vs 15.3%, p=0.02). Test characteristics of RLQ US for appendicitis also improved in the posttemplate period. A focused QI initiative led to high compliance rates of utilizing the standardized US report and resulted in lower CT use and fewer admissions for observation. Study of a Diagnostic Test Level of Evidence: 1. Copyright © 2017 Elsevier Inc. All rights reserved.
Lymphangiography in the Diagnosis and Localization of Various Chyle Leaks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deso, Steve; Ludwig, Benjamin; Kabutey, Nii-Kabu
2012-02-15
Purpose: Chyle leaks are rare entities infrequently encountered by most physicians. However, large centers providing advanced surgical care are inevitably confronted with chyle leaks as a complication of surgery, an extension of disease, or as a primary disorder. Regardless of the etiology, proper diagnosis and localization are paramount in the management of any chyle leak. Materials and Methods: Here we present 16 patients with 17 chyle leaks (5 chyluria, 8 chylothorax, and 4 chylous ascites) who underwent bipedal lymphangiography (LAG) and postprocedure computed tomography (CT) imaging. Results: In each case, the source of the chyle leak was identified and properlymore » localized to guide further treatment. Of the 16 patients who underwent LAG and postprocedure CT imaging, the initial LAG alone provided the diagnosis and localized the chyle leak in 4 patients (25%); the postprocedure CT imaging provided the diagnosis and localized the chyle leak in 6 patients (37.5%); and the two modalities were equal in the diagnosing and localizing the chyle leak in the remaining 6 patients (37.5%)ConclusionThese cases highlight the unparalleled abilities of LAG and the added benefit of post-LAG CT imaging in the diagnosis and fine anatomic localization of chyle leaks. In addition, these cases demonstrate the retained utility of LAG in these investigations despite the development of alternative tests involving CT, magnetic resonance imaging, and nuclear medicine imaging.« less
Azizian, Mohammad F; Semprini, Lewis
2017-08-01
The simultaneous anaerobic transformation of tetrachloroethene (PCE) and carbon tetrachloride (CT) was evaluated in a continuous flow column. The column was packed with quartz sand and bioaugmented with the Evanite culture (EV) that is capable of transforming PCE to ethene. Azizian and Semprini (2016) reported that PCE and CT could be simultaneously transformed in the column, with PCE (0.1mM) transformed mainly to ethene and CT (0.015mM) to chloroform (CF) (20%) and an unknown transformation product, likely carbon dioxide (CO 2 ). The fermentation of propionate, formed from lactate fermentation, was inhibited after the transformation of CT, likely from the exposure to CF. Reported here is the second phase of that study where a second bioaugmentation of the EV culture was made to reintroduce a lactate and propionate fermenting population to the column. Effective lactate and propionate fermentation were restored with a H 2 concentration of ~25nM maintained in the column effluent. PCE (0.1mM) was effectively transformed to ethene (~98%) and vinyl chloride (VC) (~2%). Unlabeled CT (0.015 to 0.03mM) was completely transformed with a transient build-up of CF and chloromethane (CM), which were subsequently removed below their detection limits. A series of transient tests were initiated through the addition of carbon-13 labeled CT ( 13 CT), with concentrations gradually increased from 0.03 to 0.10mM. GC-MS analysis of the column effluent showed that 13 C labeled CO 2 ( 13 CO 2 ) was formed, ranging from 82 to 93% of the 13 CT transformed, with the transient increases in 13 CO 2 associated with the increased concentration of 13 CT. A modified COD analysis indicated a lesser amount of 13 CT (18%) was transformed to soluble products, while 13 CO 2 represented 82% the 13 CT transformed. In a final transient test, the influent lactate concentration was decreased from 1.1 to 0.67mM. The transformation of both CT and PCE changed dramatically. Only 59% of the 13 CT was transformed, primarily to CF. 13 CO 2 concentrations gradually decreased to background levels, indicating CO 2 was no longer a transformation product. PCE transformation resulted in the following percentage of products formed: cDCE (60%), VC (36%), and ethene (4%). Incomplete propionate fermentation was also observed, consistent with the build-up of CF and the decrease in H 2 concentrations to approximately 2nM. The results clearly demonstrate that high concentrations of CT were transformed to CO 2 , and effective PCE dehalogenation to ethene was maintained when excess lactate was fed and propionate was effectively fermented. However, when the lactate concentration was reduced, both PCE and CT transformation and propionate fermentation were negatively impacted. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Azizian, Mohammad F.; Semprini, Lewis
2017-08-01
The simultaneous anaerobic transformation of tetrachloroethene (PCE) and carbon tetrachloride (CT) was evaluated in a continuous flow column. The column was packed with quartz sand and bioaugmented with the Evanite culture (EV) that is capable of transforming PCE to ethene. Azizian and Semprini (2016) reported that PCE and CT could be simultaneously transformed in the column, with PCE (0.1 mM) transformed mainly to ethene and CT (0.015 mM) to chloroform (CF) (20%) and an unknown transformation product, likely carbon dioxide (CO2). The fermentation of propionate, formed from lactate fermentation, was inhibited after the transformation of CT, likely from the exposure to CF. Reported here is the second phase of that study where a second bioaugmentation of the EV culture was made to reintroduce a lactate and propionate fermenting population to the column. Effective lactate and propionate fermentation were restored with a H2 concentration of 25 nM maintained in the column effluent. PCE (0.1 mM) was effectively transformed to ethene ( 98%) and vinyl chloride (VC) ( 2%). Unlabeled CT (0.015 to 0.03 mM) was completely transformed with a transient build-up of CF and chloromethane (CM), which were subsequently removed below their detection limits. A series of transient tests were initiated through the addition of carbon-13 labeled CT (13CT), with concentrations gradually increased from 0.03 to 0.10 mM. GC-MS analysis of the column effluent showed that 13C labeled CO2 (13CO2) was formed, ranging from 82 to 93% of the 13CT transformed, with the transient increases in 13CO2 associated with the increased concentration of 13CT. A modified COD analysis indicated a lesser amount of 13CT (18%) was transformed to soluble products, while 13CO2 represented 82% the 13CT transformed. In a final transient test, the influent lactate concentration was decreased from 1.1 to 0.67 mM. The transformation of both CT and PCE changed dramatically. Only 59% of the 13CT was transformed, primarily to CF. 13CO2 concentrations gradually decreased to background levels, indicating CO2 was no longer a transformation product. PCE transformation resulted in the following percentage of products formed: cDCE (60%), VC (36%), and ethene (4%). Incomplete propionate fermentation was also observed, consistent with the build-up of CF and the decrease in H2 concentrations to approximately 2 nM. The results clearly demonstrate that high concentrations of CT were transformed to CO2, and effective PCE dehalogenation to ethene was maintained when excess lactate was fed and propionate was effectively fermented. However, when the lactate concentration was reduced, both PCE and CT transformation and propionate fermentation were negatively impacted.
Shinozaki, Masafumi; Muramatsu, Yoshihisa; Sasaki, Toru
2014-01-01
A new technical standard for X-ray computed tomography (CT) has been published by the National Electrical Manufacturers Association (NEMA) that allows the Alert Value and Notification Value for cumulative dose to be configurable by CT systems operators in conjunction with the XR-25 (Dose check) standard. In this study, a decision method of the Notification Values for reducing the radiation dose was examined using the dose index registry (DIR) system, during 122 continuous days from August 1, 2012 to November 30, 2012. CT images were obtained using the Discovery CT 750HD (GE Healthcare) and the dose index was calculated using the DoseWatch DIR system. The CT dose index-volume (CTDIvol) and dose-length product (DLP) were output from the DIR system in comma-separated value (CSV) file format for each examination protocol. All data were shown as a schematic boxplot using statistical processing software. The CTDIvol of a routine chest examination showed the following values (maximum: 23.84 mGy; minimum: 2.55 mGy; median: 7.60 mGy; 75% tile: 10.01 mGy; 25% tile: 6.54 mGy). DLP showed the following values (maximum: 944.56 mGy·cm; minimum: 97.25 mGy·cm; median: 307.35 mGy·cm; 75% tile: 406.87 mGy·cm; 25% tile: 255.75 mGy·cm). These results indicate that the 75% tile of CTDIvol and DLP as an initial value proved to be safe and efficient for CT examination and operation. We have thus established one way of determining the Notification Value from the output of the DIR system. Transfer back to the protocol of the CT and automated processing each numeric value in the DIR system is desired.
Wang, Yongsheng; Li, Yan; Ding, Jingjing; Chen, Lulu; Dai, Jinghong; Cai, Hourong; Xiao, Yonglong; Cao, Min; Huang, Mei; Qiu, Yuying; Meng, Fanqing; Fan, Xiangshan; Zhang, Deping
2014-01-01
Background Small biopsy samples are generally considered inconclusive for bronchiolitis obliterans organizing pneumonia (BOOP) diagnosis despite their potential to reveal organizing pneumonia (OP) pathologically, necessitating risky invasive tissue biopsy during surgery for reliable confirmation. Objective OP by CT-guided lung biopsy was to evaluate the role in the diagnosis of BOOP. Methods A retrospective review of 134 cases with the OP feature in the CT-guided lung biopsy samples between 2004 and 2011 at a single center was conducted. Diagnostic accuracy of OP by CT-guided lung biopsy and clinical-radiographic data alone were compared. Results After exclusion of 11 cases due to pathology with others besides OP and 15 cases for loss to follow-up, 108 were included. Of these, 95 cases and 13 cases were classified as BOOP and non-BOOP group, respectively. Among BOOP group, only 30 were initially diagnosed as BOOP according to the typical clinical and radiographic features. The other 65 cases with atypical features were diagnosed as BOOP mainly based on OP by CT-guided lung biopsy. Among non-BOOP group, one was misdiagnosed as BOOP, and others were not BOOP according to clinical and radiographic findings. Thus, OP by CT-guided lung biopsy produced a diagnostic accuracy of 87.96% (95/108), much higher than 31.25% (30/96) observed using clinical and radiographic data alone. Combined, these techniques produced diagnostic accuracy of 98.96% (95/96). Conclusions OP by CT-guided lung biopsy can be effectively used as the pathological evidence for BOOP diagnosis and reducing unnecessary surgery. PMID:25276367
Deformable registration of x-ray to MRI for post-implant dosimetry in prostate brachytherapy
NASA Astrophysics Data System (ADS)
Park, Seyoun; Song, Danny Y.; Lee, Junghoon
2016-03-01
Post-implant dosimetric assessment in prostate brachytherapy is typically performed using CT as the standard imaging modality. However, poor soft tissue contrast in CT causes significant variability in target contouring, resulting in incorrect dose calculations for organs of interest. CT-MR fusion-based approach has been advocated taking advantage of the complementary capabilities of CT (seed identification) and MRI (soft tissue visibility), and has proved to provide more accurate dosimetry calculations. However, seed segmentation in CT requires manual review, and the accuracy is limited by the reconstructed voxel resolution. In addition, CT deposits considerable amount of radiation to the patient. In this paper, we propose an X-ray and MRI based post-implant dosimetry approach. Implanted seeds are localized using three X-ray images by solving a combinatorial optimization problem, and the identified seeds are registered to MR images by an intensity-based points-to-volume registration. We pre-process the MR images using geometric and Gaussian filtering. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine transformation and local deformable registration. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. We tested our algorithm on six patient data sets, achieving registration error of (1.2+/-0.8) mm in < 30 sec. Our proposed approach has the potential to be a fast and cost-effective solution for post-implant dosimetry with equivalent accuracy as the CT-MR fusion-based approach.
SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dise, J; McDonald, D; Ashenafi, M
Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels withmore » similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed positions would improve the algorithm speed.« less
NASA Astrophysics Data System (ADS)
Conill, Annette L.
Patients receiving Intensity Modulated Radiation Therapy (IMRT) for late stage head and neck (HN) cancer often experience anatomical changes due to weight loss, tumor regression, and positional changes of normal anatomy (1). As a result, the actual dose delivered may vary from the original treatment plan. The purpose of this study was (a) to evaluate the dosimetric consequences of the parotid glands during the course of treatment, and (b) to determine if there would be an optimal timeframe for replanning. Nineteen locally advanced HN cancer patients underwent definitive IMRT. Each patient received an initial computerized tomography simulation (CT-SIM) scan and weekly cone beam computerized tomography (CBCT) scans. A Deformable Image Registration (DIR) was performed between the CT-SIM and CBCT of the parotid glands and Planning Target Volumes (PTVs) using the Eclipse treatment planning system (TPS) and the Velocity deformation software. A recalculation of the dose was performed on the weekly CBCTs using the original monitor units. The parameters for evaluation of our method were: the changes in volume of the PTVs and parotid glands, the dose coverage of the PTVs, the lateral displacement in the Center of Mass (COM), the mean dose, and Normal Tissue Complication Probability (NTCP) of the parotid glands. The studies showed a reduction of the volume in the PTVs and parotids, a medial displacement in COM, and alterations of the mean dose to the parotid glands as compared to the initial plans. Differences were observed for the dose volume coverage of the PTVs and NTCP of the parotid gland values between the initial plan and our proposed method utilizing deformable registration-based dose calculations.
Pelotti, P; Ciminari, R; Bacci, G; Avella, M; Briccoli, A
1988-01-01
The value of stratigraphy and pulmonary CT in the initial work-up of osteosarcoma of the extremities is assessed with reference to 217 patients encountered in the Bone Tumour Centre of Rizzoli Orthopaedic Institute in May 1983-May 1986. Stratigraphy revealed lung metastases not identified by standard radiography in 4 patients (1.8%), while CT revealed metastases not identified by either standard X-rays or stratigraphy in a further 6 cases (2.7%). It is concluded that the increase in the percentage of cures (about 30%) reported in the last 10 years in osteosarcoma cases given adjuvant chemotherapy cannot be explained by any difference in initial selection due to the use of these techniques that were not adopted in the historical series.
Minami, Yasunori; Kitai, Satoshi; Kudo, Masatoshi
2012-03-01
Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. Sixty-one patients with 88 HCCs measuring 0.5-1.3 cm (mean±SD, 1.0±0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1-5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P=0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P=0.13). The safety margin should be overestimated on axial CT images in 8 nodules. Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Gabriel, Sophie; Garrigue, Philippe; Dahan, Laetitia; Castinetti, Frédéric; Sebag, Frédéric; Baumstark, Karine; Archange, Cendrine; Abhishek, Jha; Pacak, Karel; Guillet, Benjamin; Taïeb, David
2018-05-22
The 68 Ga-labelled somatostatin analogues ( 68 Ga-DOTA-SSAs) is becoming popular as an important diagnostic tool in neuroendocrine tumors as evidenced by a growing number of reports detailing institutional experience with various DOTA peptides. However, only few prospective studies have compared 68 Ga-DOTA-SSAs and somatostatin receptor scintigraphy (SRS) in gastroenteropancreatic neuroendocrine tumors (GEP-NETs) and pulmonary neuroendocrine tumors. The aim of our prospective study was to perform head-to-head comparison between 68 Ga-DOTATATE PET/CT and standard imaging work-up (SI) that included multiphasic CT, liver MRI, and SRS using single photon emission computed tomography. In this prospective study, the patients were enrolled only if they met any of the following inclusion criteria were: i- initial staging of a NETs without distant metastases on SI or neuroendocrine tumor with unknown primary on SI; ii-restaging of NETs that could be treated by focused therapeutic interventions; iii- elevated serum neuroendocrine hormones or peptides. The exclusion criteria was grade 3 GEP-NETs. Thirty-two patients were enrolled in the study. Eleven patients (6 pancreas, 4 ileum, 1 duodenal) were included for initial evaluation and staging of NETs, 8 patients (5 pancreas, 1 ileal, 1 lung, 1 duodenal gastrinoma) for restaging, and 13 patients for elevated serum neuroendocrine biomarkers (5 ectopic Cushing's syndrome, 5 organic hypoglycemia, 1 patient each with elevated vasoactive inhibitory peptide, chromogranin A, and neuron-specific enolase). 68 Ga-DOTATATE PET/CT detected more primary tumors than SRS (15/18 vs 10/18: p=0.074). The missed tumors on 68 Ga-DOTATATE PET/CT were located in the lung in 2 cases and duodenum in 1 case. For other anatomical regions (nodal and distant metastasis), no statistical difference was observed between imaging modalities using 68 Ga-DOTATATE PET/CT and SRS. Overall, 68 Ga-DOTATATE PET/CT+CT+MRI detected 31/33 of the involved regions (including primaries) (29 and 22 for 68 Ga-DOTATATE and SRS, respectively). Our study shows that 68 Ga-DOTATATE PET/CT detected similar number of sites than combination of SRS, liver MRI and thoraco-abdominopelvic CT region-based analysis. 68 Ga-DOTATATE PET/CT missed half of primary lung carcinoids with ectopic Cushing's syndrome. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Ward, Michael J; Sodickson, Aaron; Diercks, Deborah B; Raja, Ali S
2011-01-01
Computed tomography angiograms (CTAs) for patients with suspected pulmonary embolism (PE) are being ordered with increasing frequency from the emergency department (ED). Strategies are needed to safely decrease the utilization of CTs to control rising health care costs and minimize the associated risks of anaphylaxis, contrast-induced nephropathy, and radiation-induced carcinogenesis. The use of compression ultrasonography (US) to identify deep vein thromboses (DVTs) in hemodynamically stable patients with signs and symptoms suggestive of PE is highly specific for the diagnosis of PE and may represent a cost-effective alternative to CT imaging. The objective was to analyze the cost-effectiveness of a selective CT strategy incorporating the use of compression US to diagnose and treat DVT in patients with a high pretest probability of PE. The authors constructed a decision analytic model to evaluate the scenario of an otherwise healthy 59-year-old female in whom PE was being considered as a diagnosis. Two strategies were used. The selective CT strategy began with a screening compression US. Negative studies were followed up with a CTA, while patients with positive studies identifying a DVT were treated as though they had a PE and were anticoagulated. The universal CT strategy used CTA as the initial test, and anticoagulation was based on the CT result. Costs were estimated from the 2009 Medicare data for hospital reimbursement, and professional fees were obtained from the 2009 National Physician Fee Schedule. Clinical probabilities were obtained from existing published data, and sensitivity analyses were performed across plausible ranges for all clinical variables. In the base case, the selective CT strategy cost $1,457.70 less than the universal CT strategy and resulted in a gain of 0.0213 quality-adjusted life-years (QALYs). Sensitivity analyses confirm that the selective CT strategy is dominant above both a pretest probability for PE of 8.3% and a compression US specificity of 87.4%. A selective CT strategy using compression US is cost-effective for patients provided they have a high pretest probability of PE. This may reduce the need for, and decrease the adverse events associated with, CTAs. © 2010 by the Society for Academic Emergency Medicine.
van Osch, Liesbeth; Schulz, Daniela N; Kremers, Stef PJ; de Vries, Hein
2012-01-01
Background The Internet is a promising medium in the field of health promotion for offering tailored and targeted lifestyle interventions applying computer-tailored (CT) techniques to the general public. Actual exposure to CT interventions is not living up to its high expectations, as only a (limited) proportion of the target group is actually using these programs. Objective To investigate exposure to an Internet-delivered, CT lifestyle intervention, targeting physical activity, fruit and vegetable intake, smoking behavior, and alcohol intake, we focused on three processes: first use, prolonged use, and sustained use. The first objectives were to identify user characteristics that predict initiation of an online CT lifestyle program (first use) and completion of this program (prolonged use). Furthermore, we studied the effect of using a proactive strategy, consisting of periodic email prompts, on program revisits (sustained use). Methods The research population for this study consisted of Dutch adults participating in the Adult Health Monitor, offered by the regional public health services. We used a randomized controlled trial design to assess predictors of first use, prolonged use, and sustained use. Demographics and behavioral characteristics, as well as the strategy used for revisiting, were included as predictors in the model. Results A total of 9169 participants indicated their interest in the new program and 5168 actually logged in to the program. Participants significantly more likely to initiate one of the CT modules were male, older, and employed, and had a lower income, higher body mass index, and relatively unhealthy lifestyle. Participants significantly more likely to complete one of the CT modules were older and had a higher income and a relatively healthier lifestyle. Finally, using a proactive strategy influenced sustained use, with people from the prompting condition being more likely to revisit the program (odds ratio 28.92, 95% confidence interval 10.65–78.52; P < .001). Conclusions Older, male, and employed participants, and those with a lower income, higher body mass index, and a relatively unhealthy lifestyle were more likely to initiate a CT module. Module completers predominantly had a higher income and age. The current program therefore succeeded in reaching those people who benefit most from online lifestyle interventions. However, these people tended to disengage from the program. This underlines the importance of additional research into program adjustments and strategies that can be used to stimulate prolonged program use. Furthermore, sending periodic email prompts significantly increased revisits to the program. Though promising, this effect was modest and needs to be further examined, in order to maximize the potential of periodic email prompting. Trial Registration Nederlands Trial Register (NTR: 1786) and Medical Ethics Committee of Maastricht University and the University Hospital Maastricht (NL2723506809/MEC0903016); http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=1786 (Archived by WebCite at http://www.webcitation.org/65hBXA6V7) PMID:22382037
Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries.
Lemburg, Stefan P; Peters, Soeren A; Roggenland, Daniela; Nicolas, Volkmar; Heyer, Christoph M
2010-12-01
The purpose of this study was to analyze the quantity and distribution of cumulative effective doses in diagnostic imaging of adolescents with spinal injuries. At a level 1 trauma center from July 2003 through June 2009, imaging procedures during initial evaluation and hospitalization and after discharge of all patients 10-20 years old with spinal fractures were retrospectively analyzed. The cumulative effective doses for all imaging studies were calculated, and the doses to patients with spinal injuries who had multiple traumatic injuries were compared with the doses to patients with spinal injuries but without multiple injuries. The significance level was set at 5%. Imaging studies of 72 patients (32 with multiple injuries; average age, 17.5 years) entailed a median cumulative effective dose of 18.89 mSv. Patients with multiple injuries had a significantly higher total cumulative effective dose (29.70 versus 10.86 mSv, p < 0.001) mainly owing to the significantly higher CT-related cumulative effective dose to multiple injury patients during the initial evaluation (18.39 versus 2.83 mSv, p < 0.001). Overall, CT accounted for 86% of the total cumulative effective dose. Adolescents with spinal injuries receive a cumulative effective dose equal to that of adult trauma patients and nearly three times that of pediatric trauma patients. Areas of focus in lowering cumulative effective dose should be appropriate initial estimation of trauma severity and careful selection of CT scan parameters.
Diagnostic imaging for acute appendicitis: interfacility differences in practice patterns.
Michailidou, Maria; Sacco Casamassima, Maria G; Karim, Omar; Gause, Colin; Salazar, Jose H; Goldstein, Seth D; Abdullah, Fizan
2015-04-01
To evaluate trends and factors associated with interfacility differences in imaging modality selection in the diagnosis and management of children with suspected acute appendicitis. We conducted a retrospective review of diagnostic imaging selection and outcomes in patients <20 years of age who underwent appendectomy at a single Children's Hospital from June 2008 to June 2013. These results were then compared with those of referring hospitals. A total of 232 children underwent appendectomy during the study period. Imaging results contributed to diagnostic and management decisions in 95.3 % of cases. CT scan was utilized as first-line imaging in 50 % of cases. CTs were preferentially performed at referring institutions (78 vs. 46 %, p < 0.001). Children were five times more likely to undergo CT at referring institutions (OR = 5.5, CI 3.0-10.2). Adjusting for demographics and Alvarado score, diagnostic imaging choice was independent of patient's clinical status. This study demonstrates that initial presentation to a referring hospital independently predicts the use of CT scan for suspected acute appendicitis. Further efforts should be undertaken to develop a clinical pathway that minimizes radiation exposure in the diagnosis of acute appendicitis, with focus on access to pediatric abdominal ultrasound.
Apter-Levi, Yael; Pratt, Maayan; Vakart, Adam; Feldman, Michal; Zagoory-Sharon, Orna; Feldman, Ruth
2016-02-01
Maternal depression across the first years of life negatively impacts children's development. One pathway of vulnerability may involve functioning of the hypothalamic-pituitary-adrenal (HPA) axis. We utilize a community cohort of 1983 women with no comorbid risk repeatedly assessed for depression from birth to six years to form two groups; chronically depressed (N=40) and non-depressed (N=91) women. At six years, mother and child underwent psychiatric diagnosis, child salivary cortisol (CT) was assessed three times during a home-visit, mother-child interaction was videotaped, and child empathy was coded from behavioral paradigms. Latent Growth curve Model using Structural Equation Modeling (SEM) estimated the links between maternal depression and mother's negative parenting and three child outcomes; psychopathology, social withdrawal, and empathy as related to child CT baseline and variability. Depressed mothers displayed more negative parenting and their children showed more Axis-I psychopathology and social withdrawal. SEM analysis revealed that maternal depression was associated with reduced CT variability, which predicted higher child psychopathology and social withdrawal. Whereas all children exhibited similar initial levels of CT, children of controls reduced CT levels over time while children of depressed mothers maintained high, non-flexible levels. Mother negativity was related to lower initial CT levels, which predicted decreased empathy. Findings suggest that chronic maternal depression may compromise children's social-emotional adjustment by diminishing HPA-system flexibility as well as limiting the mother's capacity to provide attuned and predictable caregiving. Copyright © 2015 Elsevier Ltd. All rights reserved.
Factors influencing residual pleural opacity in tuberculous pleural effusion.
Kwon, Jee Sook; Cha, Seung-Ick; Jeon, Kyung-Nyeo; Kim, Young-Joo; Kim, Eun-Jin; Kim, Chang-Ho; Park, Jae-Yong; Jung, Tae-Hoon
2008-08-01
Tuberculous pleural effusion (TPE) leads to residual pleural opacity (RPO) in a significant proportion of cases. The aim of this study was to investigate which TPE patients would have RPO following the treatment. This study was performed prospectively for a total of 60 TPE patients, who underwent pleural fluid analysis on the initial visit and chest radiographs and computed tomography (CT) scans before and after the administration of antituberculous medication. At the end of antituberculous medication, the incidence of RPO was 68.3% (41/60) on CT with a range of 2-50 mm. Compared with the non-RPO group, the RPO group had a longer symptom duration and lower pleural fluid glucose level. On initial CT, loculation, extrapleural fat proliferation, increased attenuation of extrapleural fat, and pleura-adjacent atelectasis were more frequent, and parietal pleura was thicker in the RPO group compared with the non-RPO group. By multivariate analysis, extrapleural fat proliferation, loculated effusion, and symptom duration were found to be predictors of RPO in TPE. In conclusion, RPO in TPE may be predicted by the clinico-radiologic parameters related to the chronicity of the effusion, such as symptom duration and extrapleural fat proliferation and loculated effusion on CT.
The Emergent Landscape of Detecting EGFR Mutations Using Circulating Tumor DNA in Lung Cancer
Wei, Fang; Wong, David T.; Su, Wu-Chou
2015-01-01
The advances in targeted therapies for lung cancer are based on the evaluation of specific gene mutations especially the epidermal growth factor receptor (EGFR). The assays largely depend on the acquisition of tumor tissue via biopsy before the initiation of therapy or after the onset of acquired resistance. However, the limitations of tissue biopsy including tumor heterogeneity and insufficient tissues for molecular testing are impotent clinical obstacles for mutation analysis and lung cancer treatment. Due to the invasive procedure of tissue biopsy and the progressive development of drug-resistant EGFR mutations, the effective initial detection and continuous monitoring of EGFR mutations are still unmet requirements. Circulating tumor DNA (ctDNA) detection is a promising biomarker for noninvasive assessment of cancer burden. Recent advancement of sensitive techniques in detecting EGFR mutations using ctDNA enables a broad range of clinical applications, including early detection of disease, prediction of treatment responses, and disease progression. This review not only introduces the biology and clinical implementations of ctDNA but also includes the updating information of recent advancement of techniques for detecting EGFR mutation using ctDNA in lung cancer. PMID:26448936
Generali, Daniele; Corona, Silvia Paola; Pusztai, Lajos; Rouzier, Roman; Allevi, Giovanni; Aguggini, Sergio; Milani, Manuela; Strina, Carla; Frati, Albane
2018-03-01
Neoadjuvant hormonal therapy is generally considered a valid option for hormone receptor positive breast cancer (BC) patients who are unfit for chemotherapy or surgery. Whilst numerous studies analyzed efficacy of neoadjuvant chemotherapy (CT) or endocrine therapy (HT) alone in hormone receptor positive patients, there is a lack of research looking at the usefulness of a preoperative combinatorial approach of CT and HT in this patient subgroup. Using a predictive model previously described in the literature, developed to analyze the probability of benefit from preoperative chemotherapy, we were able to compare pathological complete response (pCR) rates expected with the use of CT alone with the pCR rates reported in a population of 192 patients treated with the combination of tamoxifen plus anthracycline-based CT at Cremona Hospital between 2003 and 2006. Even with a relatively small patient population, this approach provided insightful information for the selection of hormone receptor positive BC patients most likely to benefit from the use of preoperative HT and CT in combination. Whilst no statistically significant benefit was obtained with the addition of tamoxifen to neoadjuvant chemotherapy in the entire population, or in any of the molecular stratification subgroups, the analysis of the calibration curve showed that a combinatorial approach may improve pCR in patients with luminal B tumors. More specific trials should be designed to confirm our initial results. To the best of our knowledge, this is the first report investigating the efficacy of the combination of CT and HT in the neoadjuvant treatment of hormone receptor positive BC.
Glemser, Philip A; Pfleiderer, Michael; Heger, Anna; Tremper, Jan; Krauskopf, Astrid; Schlemmer, Heinz-Peter; Yen, Kathrin; Simons, David
2017-03-01
The aim of this multi-reader feasibility study was to evaluate new post-processing CT imaging tools in rib fracture assessment of forensic cases by analyzing detection time and diagnostic accuracy. Thirty autopsy cases (20 with and 10 without rib fractures in autopsy) were randomly selected and included in this study. All cases received a native whole body CT scan prior to the autopsy procedure, which included dissection and careful evaluation of each rib. In addition to standard transverse sections (modality A), CT images were subjected to a reconstruction algorithm to compute axial labelling of the ribs (modality B) as well as "unfolding" visualizations of the rib cage (modality C, "eagle tool"). Three radiologists with different clinical and forensic experience who were blinded to autopsy results evaluated all cases in a random manner of modality and case. Rib fracture assessment of each reader was evaluated compared to autopsy and a CT consensus read as radiologic reference. A detailed evaluation of relevant test parameters revealed a better accordance to the CT consensus read as to the autopsy. Modality C was the significantly quickest rib fracture detection modality despite slightly reduced statistic test parameters compared to modalities A and B. Modern CT post-processing software is able to shorten reading time and to increase sensitivity and specificity compared to standard autopsy alone. The eagle tool as an easy to use tool is suited for an initial rib fracture screening prior to autopsy and can therefore be beneficial for forensic pathologists.
Goo, Hyun Woo; Allmendinger, Thomas
2017-01-01
Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. In total, 15 children (median age 19 months, range 6 months-8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children.
WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ingram, W; Rao, A; Wendt, R
Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded asmore » it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration framework that is clinically valuable and requires no specialized equipment.« less
Springer, Lindsay F; Chen, Lei-An; Stahlecker, Avery C; Cousins, Peter; Sacks, Gavin L
2016-11-02
In red winemaking, the extractability of condensed tannins (CT) can vary considerably even under identical fermentation conditions, and several explanations for this phenomenon have been proposed. Recent work has demonstrated that grape pathogenesis-related proteins (PRPs) may limit retention of CT added to finished wines, but their relevance to CT extractability has not been evaluated. In this work, Vitis vinifera and interspecific hybrids (Vitis ssp.) from both hot and cool climates were vinified under small-scale, controlled conditions. The final CT concentration in wine was well modeled from initial grape tannin and juice protein concentrations using the Freundlich equation (r 2 = 0.686). In follow-up experiments, separation and pretreatment of juice by bentonite, heating, freezing, or exogenous tannin addition reduced protein concentrations in juices from two grape varieties. The bentonite treatment also led to greater wine CT for one of the varieties, indicating that prefermentation removal of grape protein may be a viable approach to increasing wine CT.
Bolliger, Stephan A; Ross, Steffen; Thali, Michael J; Hostettler, Bernhard; Menkveld-Gfeller, Ursula
2012-01-01
The study of fossils permits the reconstruction of past life on our planet and enhances our understanding of evolutionary processes. However, many fossils are difficult to recognize, being encased in a lithified matrix whose tedious removal is required before examination is possible. The authors describe the use of multidetector computed tomography (CT) in locating, identifying, and examining fossil remains of crocodilians (Mesosuchia) embedded in hard shale, all without removing the matrix. In addition, they describe how three-dimensional (3D) reformatted CT images provided details that were helpful for extraction and preparation. Multidetector CT can help experienced paleontologists localize and characterize fossils in the matrix of a promising rock specimen in a nondestructive manner. Moreover, with its capacity to generate highly accurate 3D images, multidetector CT can help determine whether the fossils warrant extraction and can assist in planning the extraction process. Thus, multidetector CT may well become an invaluable tool in the field of paleoradiology.
Iwamuro, Masaya; Tanaka, Shouichi; Moritou, Yuki; Inaba, Tomoki; Higashi, Reiji; Kusumoto, Chiaki; Yunoki, Naoko; Ishikawa, Shin; Okamoto, Yuko; Kawai, Yoshinari; Kitada, Ken-Ichi; Takenaka, Ryuta; Toyokawa, Tatsuya; Okada, Hiroyuki
2017-06-01
Most gastric bezoars can be treated with endoscopic fragmentation combined with or without cola dissolution, whereas laparotomy or laparoscopic surgery is generally inevitable for small intestinal bezoars because they cause small bowel obstruction. Therefore, early diagnosis and management of gastric bezoars are necessary to prevent bezoar-induced ileus. To investigate the incidence of overlooked gastric bezoars during the initial esophagogastroduodenoscopy, we retrospectively reviewed the cases of 27 patients diagnosed with gastrointestinal bezoars. The bezoars were diagnosed using esophagogastroduodenoscopy (n=25), abdominal ultrasonography (n=1), and barium follow-through examination (n=1). Bezoars were overlooked in 9/25 patients (36.0%) during the initial endoscopy examination because the bezoars were covered with debris in the stomach. Of the 9 patients, 8 had concomitant gastric ulcers, and the other patient had gastric lymphoma. Although a computed tomography (CT) scan was performed before the second-look endoscopy in 8 of the 9 patients, the bezoars were mistaken as food debris on CT findings and were overlooked in these patients. In conclusion, gastric bezoars may not be discovered during the initial esophagogastroduodenoscopy and CT scan. In cases with debris in the stomach, second-look endoscopy is essential to detect bezoars.
Nuechterlein, Keith H; Ventura, Joseph; McEwen, Sarah C; Gretchen-Doorly, Denise; Vinogradov, Sophia; Subotnik, Kenneth L
2016-07-01
Cognitive training (CT) and aerobic exercise have separately shown promise for improving cognitive deficits in schizophrenia. Aerobic exercise releases brain-derived neurotrophic factor, which promotes synaptic plasticity and neurogenesis. Thus, aerobic exercise provides a neurotrophic platform for neuroplasticity-based CT. The combination of aerobic exercise and CT may yield more robust effects than CT alone, particularly in the initial course of schizophrenia. In a pilot study, 7 patients with a recent onset of schizophrenia were assigned to Cognitive Training & Exercise (CT&E) and 9 to CT alone for a 10-week period. Posit Science programs were used for CT. Neurocognitive training focused on tuning neural circuits related to perceptual processing and verbal learning and memory. Social cognitive training used the same learning principles with social and affective stimuli. Both groups participated in these training sessions 2d/wk, 2h/d. The CT&E group also participated in an aerobic conditioning program for 30 minutes at our clinic 2d/wk and at home 2d/wk. The effect size for improvement in the MATRICS Consensus Cognitive Battery Overall Composite score for CT&E patients relative to CT patients was large. Functional outcome, particularly independent living skills, also tended to improve more in the CT&E than in the CT group. Muscular endurance, cardiovascular fitness, and diastolic blood pressure also showed relative improvement in the CT&E compared to the CT group. These encouraging pilot study findings support the promise of combining CT and aerobic exercise to improve the early course of schizophrenia. © The Author 2016. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center. All rights reserved. For permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deniaud-Alexandre, Elisabeth; Touboul, Emmanuel; Lerouge, Delphine
2005-12-01
Purpose: To report a retrospective study concerning the impact of fused {sup 18}F-fluoro-deoxy-D-glucose (FDG)-hybrid positron emission tomography (PET) and CT images on three-dimensional conformal radiotherapy planning for patients with non-small-cell lung cancer. Methods and Materials: A total of 101 patients consecutively treated for Stage I-III non-small-cell lung cancer were studied. Each patient underwent CT and FDG-hybrid PET for simulation treatment in the same treatment position. Images were coregistered using five fiducial markers. Target volume delineation was initially performed on the CT images, and the corresponding FDG-PET data were subsequently used as an overlay to the CT data to define themore » target volume. Results: {sup 18}F-fluoro-deoxy-D-glucose-PET identified previously undetected distant metastatic disease in 8 patients, making them ineligible for curative conformal radiotherapy (1 patient presented with some positive uptake corresponding to concomitant pulmonary tuberculosis). Another patient was ineligible for curative treatment because the fused PET-CT images demonstrated excessively extensive intrathoracic disease. The gross tumor volume (GTV) was decreased by CT-PET image fusion in 21 patients (23%) and was increased in 24 patients (26%). The GTV reduction was {>=}25% in 7 patients because CT-PET image fusion reduced the pulmonary GTV in 6 patients (3 patients with atelectasis) and the mediastinal nodal GTV in 1 patient. The GTV increase was {>=}25% in 14 patients owing to an increase in the pulmonary GTV in 11 patients (4 patients with atelectasis) and detection of occult mediastinal lymph node involvement in 3 patients. Of 81 patients receiving a total dose of {>=}60 Gy at the International Commission on Radiation Units and Measurements point, after CT-PET image fusion, the percentage of total lung volume receiving >20 Gy increased in 15 cases and decreased in 22. The percentage of total heart volume receiving >36 Gy increased in 8 patients and decreased in 14. The spinal cord volume receiving at least 45 Gy (2 patients) decreased. Multivariate analysis showed that tumor with atelectasis was the single independent factor that resulted in a significant effect on the modification of the size of the GTV by FDG-PET: tumor with atelectasis (with vs. without atelectasis, p = 0.0001). Conclusion: The results of our study have confirmed that integrated hybrid PET/CT in the treatment position and coregistered images have an impact on treatment planning and management of non-small-cell lung cancer. However, FDG images using dedicated PET scanners and respiration-gated acquisition protocols could improve the PET-CT image coregistration. Furthermore, the impact on treatment outcome remains to be demonstrated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giaddui, T; Li, N; Moore, K
Purpose: To establish a workflow for NRG-GY006 IMRT pre-treatment reviews, incorporating advanced radiotherapy technologies being evaluated as part of the clinical trial. Methods: Pre-Treatment reviews are required for every IMRT case as part of NRG-GY006 (a randomized phase II trial of radiation therapy and cisplatin alone or in combination with intravenous triapine in women with newly diagnosed bulky stage I B2, stage II, IIIB, or IVA cancer of the uterine cervix or stage II-IVA vaginal cancer. The pretreatment review process includes structures review and generating an active bone marrow(ABM)- to be used as an avoidance structure during IMRT optimization- andmore » evaluating initial IMRT plan quality using knowledgeengineering based planning (KBP). Institutions will initially submit their simulation CT scan, structures file and PET/CT to IROC QA center for generating ABM. The ABM will be returned to the institution for use in planning. Institutions will then submit an initial IMRT plan for review and will receive information back following implementation of a KBP algorithm, for use in re-optimization, before submitting the final IMRT used for treatment. Results: ABM structure is generated using MIM vista software (Version 6.5, MIM corporation, Inc.). Here, the planning CT and the diagnostic PET/CT are fused and a sub threshold structure is auto segmented above the mean value of the SUV of the bone marrow. The generated ABM were compared with those generated with other software system (e.g. Velocity, Varian) and Dice coefficient (reflects the overlap of structures) ranged between 80 – 90% was achieved. A KBP model was built in Varian Eclipse TPS using the RapidPlan KBP software to perform plan quality assurance. Conclusion: The workflow for IMRT pretreatment reviews has been established. It represents a major improvement of NRG Oncology clinical trial quality assurance and incorporates the latest radiotherapy technologies as part of NCI clinical trials. This project was supported by grants U24CA180803 (IROC), UG1CA189867 (NCORP), U10CA180868 (NRG Oncology Operations), U10CA180822 (NRG Oncology SDMC) from the National Cancer Institute (NCI) and PA CURE grant.« less
Punwani, Shonit; Taylor, Stuart A; Bainbridge, Alan; Prakash, Vineet; Bandula, Steven; De Vita, Enrico; Olsen, Oystein E; Hain, Sharon F; Stevens, Nicola; Daw, Stephen; Shankar, Ananth; Bomanji, Jamshed B; Humphries, Paul D
2010-04-01
To compare the diagnostic performance of rapid whole-body anatomic magnetic resonance (MR) staging of pediatric and adolescent lymphoma to an enhanced positron emission tomographic (PET)/computed tomographic (CT) reference standard. Ethical permission was given by the University College London Hospital ethics committee, and informed written consent was obtained from all participants and/or parents or guardians. Thirty-one subjects (age range, 7.3-18.0 years; 18 male, 11 female) with histologically proved lymphoma were prospectively recruited. Pretreatment staging was performed with whole-body short inversion time inversion-recovery (STIR) half-Fourier rapid acquisition with relaxation enhancement (RARE) MR imaging, fluorine 18 fluorodeoxyglucose PET/CT, and contrast agent-enhanced chest CT. Twenty-six subjects had posttreatment PET/CT and compromised our final cohort. Eleven nodal and 11 extranodal sites per patient were assessed on MR imaging by two radiologists in consensus, with a nodal short-axis threshold of >1 cm and predefined extranodal positivity criteria. The same sites were independantly evaluated by two nuclear medicine physicians on PET/CT images. Disease positivity was defined as a maximum standardized uptake value >2.5 or nodal size >1 cm. An unblinded expert panel reevaluated the imaging findings, removing perceptual errors, and derived an enhanced PET/CT reference standard (taking into account chest CT and 3-month follow-up imaging) against which the reported and intrinsic performance of MR imaging was assessed by using the kappa statistic. There was very good agreement between MR imaging and the enhanced PET/CT reference standard for nodal and extranodal staging (kappa = 0.96 and 0.86, respectively) which improved following elimination of perceptual errors (kappa = 0.97 and 0.91, respectively). The sensitivity and specificity of MR imaging (following removal of perceptual error) were 98% and 99%, respectively, for nodal disease and 91% and 99%, respectively, for extranodal disease. Whole-body STIR half-Fourier RARE MR imaging of pediatric and adolescent lymphoma can accurately depict nodal and extranodal disease and may provide an alternative nonionizing imaging method for anatomic disease assessment at initial staging. RSNA, 2010
Li, Nanxin; Hao, Yanni; Xie, Jipan; Lin, Peggy L; Zhou, Zhou; Zhong, Yichen; Signorovitch, James E; Wu, Eric Q
2015-08-01
Everolimus has been shown to be an effective HR+/HER2- mBC treatment in both clinical trials and real-world practice. The current study aims at understanding factors associated with everolimus use and how it is used in the real world. A retrospective chart review was conducted among postmenopausal HR+/HER2- mBC women who received everolimus, endocrine therapy (ET), or chemotherapy (CT) for mBC between 1 July 2012 and 15 April 2013 after an NSAI failure. Factors associated with everolimus use versus ET or CT were identified using multivariable logistic regressions. Reasons for prescribing everolimus and everolimus treatment patterns were described. Liver metastasis and high tumor volume were associated with a higher likelihood of everolimus use versus ET (OR = 1.67, OR = 1.62) but a lower likelihood of everolimus use versus CT (OR = 0.43, OR = 0.30). Medicare-only insurance (OR = 0.30) as well as ECOG ≥2 (OR = 3.72) and prior CT in mBC (OR = 2.76) were associated with a lower and higher likelihood of everolimus use versus CT, respectively. The top reason for prescribing everolimus was efficacy (69-85%). About 15% and 29% of everolimus users in second line and third line or above received prior CT for mBC. Exemestane was the most common concomitant therapy with everolimus (56-87%). The majority of patients initiated everolimus at the labeled dose of 10 mg daily (>80%) and maintained this dose (>80%). In the real world, everolimus was used in more severe patients than ET but less severe patients than CT based on visceral metastasis, tumor volume, and performance status. The top reason for prescribing everolimus was efficacy. A large proportion of patients received first or second line CT before everolimus initiation. The majority of patients used everolimus according to the labeled combination and dose. Future studies are needed to determine optimal sequencing of everolimus, ET, and CT for HR+/HER2- mBC.
Ruth, Veikko; Kolditz, Daniel; Steiding, Christian; Kalender, Willi A
2017-06-01
The performance of metal artifact reduction (MAR) methods in x-ray computed tomography (CT) suffers from incorrect identification of metallic implants in the artifact-affected volumetric images. The aim of this study was to investigate potential improvements of state-of-the-art MAR methods by using prior information on geometry and material of the implant. The influence of a novel prior knowledge-based segmentation (PS) compared with threshold-based segmentation (TS) on 2 MAR methods (linear interpolation [LI] and normalized-MAR [NORMAR]) was investigated. The segmentation is the initial step of both MAR methods. Prior knowledge-based segmentation uses 3-dimensional registered computer-aided design (CAD) data as prior knowledge to estimate the correct position and orientation of the metallic objects. Threshold-based segmentation uses an adaptive threshold to identify metal. Subsequently, for LI and NORMAR, the selected voxels are projected into the raw data domain to mark metal areas. Attenuation values in these areas are replaced by different interpolation schemes followed by a second reconstruction. Finally, the previously selected metal voxels are replaced by the metal voxels determined by PS or TS in the initial reconstruction. First, we investigated in an elaborate phantom study if the knowledge of the exact implant shape extracted from the CAD data provided by the manufacturer of the implant can improve the MAR result. Second, the leg of a human cadaver was scanned using a clinical CT system before and after the implantation of an artificial knee joint. The results were compared regarding segmentation accuracy, CT number accuracy, and the restoration of distorted structures. The use of PS improved the efficacy of LI and NORMAR compared with TS. Artifacts caused by insufficient segmentation were reduced, and additional information was made available within the projection data. The estimation of the implant shape was more exact and not dependent on a threshold value. Consequently, the visibility of structures was improved when comparing the new approach to the standard method. This was further confirmed by improved CT value accuracy and reduced image noise. The PS approach based on prior implant information provides image quality which is superior to TS-based MAR, especially when the shape of the metallic implant is complex. The new approach can be useful for improving MAR methods and dose calculations within radiation therapy based on the MAR corrected CT images.
Imaging infection with 18F-FDG-labeled leukocyte PET/CT: initial experience in 21 patients.
Dumarey, Nicolas; Egrise, Dominique; Blocklet, Didier; Stallenberg, Bernard; Remmelink, Myriam; del Marmol, Véronique; Van Simaeys, Gaëtan; Jacobs, Frédérique; Goldman, Serge
2006-04-01
The aim of this study was to assess the feasibility and the potential role of PET/CT with (18)F-FDG-labeled autologous leukocytes in the diagnosis and localization of infectious lesions. Twenty-one consecutive patients with suspected or documented infection were prospectively evaluated with whole-body PET/CT 3 h after injection of autologous (18)F-FDG-labeled leukocytes. Two experienced nuclear medicine physicians who were unaware of the clinical end-diagnosis reviewed all PET/CT studies. A visual score (0-3)-according to uptake intensity-was used to assess studies. The results of PET/CT with (18)F-FDG-labeled white blood cell ((18)F-FDG-WBC) assessment were compared with histologic or biologic diagnosis in 15 patients and with clinical end-diagnosis after complete clinical work-up in 6 patients. Nine patients had fever of unknown etiology, 6 patients had documented infection but with unknown extension of the infectious disease, 4 patients had a documented infection with unfavorable evolution, and 2 patients had a documented infection with known extension. The best trade-off between sensitivity and specificity was obtained when a visual score of >or=2 was chosen to identify increased tracer uptake as infection. With this threshold, sensitivity, specificity, and accuracy were each 86% on a patient-per-patient basis and 91%, 85%, and 90% on a lesion-per-lesion basis. In this small group of patients, the absence of areas with increased WBC uptake on WBC PET/CT had a 100% negative predictive value. Hybrid (18)F-FDG-WBC PET/CT was found to have a high sensitivity and specificity for the diagnosis of infection. It located infectious lesions with a high precision. In this small series, absence of areas with increased uptake virtually ruled out the presence of infection. (18)F-FDG-WBC PET/CT for infection detection deserves further investigation in a larger prospective series.
Catalano, Onofrio Antonio; Daye, Dania; Signore, Alberto; Iannace, Carlo; Vangel, Mark; Luongo, Angelo; Catalano, Marco; Filomena, Mazzeo; Mansi, Luigi; Soricelli, Andrea; Salvatore, Marco; Fuin, Niccolo; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce Robert
2017-07-01
The aim of the present study was to evaluate the performance of whole-body diffusion-weighted imaging (WB-DWI), whole-body positron emission tomography with computed tomography (WB-PET/CT), and whole-body positron emission tomography with magnetic resonance imaging (WB-PET/MRI) in staging patients with untreated invasive ductal carcinoma of the breast. Fifty-one women with newly diagnosed invasive ductal carcinoma of the breast underwent WB-DWI, WB-PET/CT and WB-PET/MRI before treatment. A radiologist and a nuclear medicine physician reviewed in consensus the images from the three modalities and searched for occurrence, number and location of metastases. Final staging, according to each technique, was compared. Pathology and imaging follow-up were used as the reference. WB-DWI, WB-PET/CT and WB-PET/MRI correctly and concordantly staged 33/51 patients: stage IIA in 7 patients, stage IIB in 8 patients, stage IIIC in 4 patients and stage IV in 14 patients. WB-DWI, WB-PET/CT and WB-PET/MRI incorrectly and concordantly staged 1/51 patient as stage IV instead of IIIA. Discordant staging was reported in 17/51 patients. WB-PET/MRI resulted in improved staging when compared to WB-PET/CT (50 correctly staged on WB-PET/MRI vs. 38 correctly staged on WB-PET/CT; McNemar's test; p<0.01). Comparing the performance of WB-PET/MRI and WB-DWI (43 correct) did not reveal a statistically significant difference (McNemar test, p=0.14). WB-PET/MRI is more accurate in the initial staging of breast cancer than WB-DWI and WB-PET/CT, however, the discrepancies between WB-PET/MRI and WB-DWI were not statistically significant. When available, WB-PET/MRI should be considered for staging patient with invasive ductal breast carcinoma.
2014-01-01
Background Fort Bragg, a large Army installation with reported high Chlamydia trachomatis (Ct) infection rates, is characterized by a highly mobile population and a surrounding Ct-endemic community. We assessed the rates of Ct incidence and recurrence among the installation’s active component Army personnel and determined the association of soldier transience, sociodemographic factors, and history of sexually transmitted infection (STI) with these rates. Methods A cohort of soldiers stationed at Fort Bragg during 2005 to mid-2010 was followed for incident and recurrent Ct infection using laboratory-confirmed reportable disease data. Linkage to demographic and administrative data permitted multivariate analysis to determine association of covariates with initial or recurrent infection. Results Among 67,425 soldiers, 2,198 (3.3%) contracted an incident Ct infection (crude incidence, 21.7 per 1,000 person-years). Among soldiers followed for incident infection, 223 (10.6%, crude incidence 110.8 per 1,000 person-years) contracted a recurrent Ct infection. Being female, of lower rank, under 26 years of age, of non-white race, single, or with a high school diploma or less was significantly associated with incident Ct infection. Having breaks in duty or having deployments during follow-up was associated with a lower infection rate. Among women, having prior deployments was associated with a lower rate of both incident and recurrent infection. Specifically associated with recurrent infection in women was age under 21 years or no education beyond high school. Conclusions This analysis reaffirms risk factors for Ct infection determined in other studies. In addition, infection risk was lower for more mobile soldiers and tied to the specific location of their regular duty assignment. The findings support the STI prevention efforts at Fort Bragg and the surrounding community, regardless of how often or for how long soldiers have deployed for military operations. PMID:24552420
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chao, M; Yuan, Y; Lo, Y
Purpose: To develop a novel strategy to extract the lung tumor motion from cone beam CT (CBCT) projections by an active contour model with interpolated respiration learned from diaphragm motion. Methods: Tumor tracking on CBCT projections was accomplished with the templates derived from planning CT (pCT). There are three major steps in the proposed algorithm: 1) The pCT was modified to form two CT sets: a tumor removed pCT and a tumor only pCT, the respective digitally reconstructed radiographs DRRtr and DRRto following the same geometry of the CBCT projections were generated correspondingly. 2) The DRRtr was rigidly registered withmore » the CBCT projections on the frame-by-frame basis. Difference images between CBCT projections and the registered DRRtr were generated where the tumor visibility was appreciably enhanced. 3) An active contour method was applied to track the tumor motion on the tumor enhanced projections with DRRto as templates to initialize the tumor tracking while the respiratory motion was compensated for by interpolating the diaphragm motion estimated by our novel constrained linear regression approach. CBCT and pCT from five patients undergoing stereotactic body radiotherapy were included in addition to scans from a Quasar phantom programmed with known motion. Manual tumor tracking was performed on CBCT projections and was compared to the automatic tracking to evaluate the algorithm accuracy. Results: The phantom study showed that the error between the automatic tracking and the ground truth was within 0.2mm. For the patients the discrepancy between the calculation and the manual tracking was between 1.4 and 2.2 mm depending on the location and shape of the lung tumor. Similar patterns were observed in the frequency domain. Conclusion: The new algorithm demonstrated the feasibility to track the lung tumor from noisy CBCT projections, providing a potential solution to better motion management for lung radiation therapy.« less
Yang, Dong Hyun; Kim, Namkug; Park, Seung Il; Kim, Dong Kwan; Kim, Ellen Ai-Rhan
2011-01-01
Objective We wanted to evaluate the resistance to collateral ventilation in congenital hyperlucent lung lesions and to correlate that with the anatomic findings on xenon-enhanced dynamic dual-energy CT. Materials and Methods Xenon-enhanced dynamic dual-energy CT was successfully and safely performed in eight children (median age: 5.5 years, 4 boys and 4 girls) with congenital hyperlucent lung lesions. Functional assessment of the lung lesions on the xenon map was done, including performing a time-xenon value curve analysis and assessing the amplitude of xenon enhancement (A) value, the rate of xenon enhancement (K) value and the time of arrival value. Based on the A value, the lung lesions were categorized into high or low (A value > 10 Hounsfield unit [HU]) resistance to collateral ventilation. In addition, the morphologic CT findings of the lung lesions, including cyst, mucocele and an accessory or incomplete fissure, were assessed on the weighted-average CT images. The xenon-enhanced CT radiation dose was estimated. Results Five of the eight lung lesions were categorized into the high resistance group and three lesions were categorized into the low resistance group. The A and K values in the normal lung were higher than those in the low resistance group. The time of arrival values were delayed in the low resistance group. Cysts were identified in five lesions, mucocele in four, accessory fissure in three and incomplete fissure in two. Either cyst or an accessory fissure was seen in four of the five lesions showing high resistance to collateral ventilation. The xenon-enhanced CT radiation dose was 2.3 ± 0.6 mSv. Conclusion Xenon-enhanced dynamic dual-energy CT can help visualize and quantitate various degrees of collateral ventilation to congenital hyperlucent lung lesions in addition to assessing the anatomic details of the lung. PMID:21228937
Gómez-de la Fuente, F J; Martínez-Rodríguez, I; de Arcocha-Torres, M; Quirce, R; Jiménez-Bonilla, J; Martínez-Amador, N; Banzo, I
11 C-choline PET/CT has demonstrated good results in the restaging of prostate cancer (PCa) with high serum prostate specific antigen (PSA), but its use in patients with low serum PSA is controversial. Our aim was to evaluate the contribution of 11 C-choline PET/CT in patients with PCa, biochemical relapse and PSA <1 ng/ml. Fifty consecutive patients (mean age: 65.9±5.6 years) with biochemical relapse of PCa and serum PSA <1ng/ml were evaluated retrospectively. PET/CT was performed 20min after intravenous administration of 555-740 MBq of 11 C-choline. Minimum follow up time was 30 months. Twenty-one out of 50 patients (42%) had an abnormal 11 C-choline PET/CT. In 7 out of 21 patients (14%) tumor was confirmed (4 in prostatic bed, 4 in pelvic lymph nodes, 2 in mediastinal lymph nodes and one synchronous sigmoid carcinoma), and in all cases the initial therapeutic planning was modified. In 2 patients (4%) subsequent tests diagnosed a benign disease (one sarcoidosis, one tuberculosis sequelae) and in 3 patients (6%) they ruled out pathology. The other 9 patients (18%) had no further assessment (7 mediastinal and 4 pelvic lymph nodes). Twenty-nine out of 50 patients (58%) had a normal PET/CT. At 30 months, follow up recurrence was confirmed only in 2 of these patients. 11 C-choline PET/CT proved its usefulness in demonstrating tumor in 14% of patients with BR of PCa and serum PSA <1ng/ml, with therapeutic implications. In 4% of patients a benign condition was detected. A normal 11 C-choline PET/CT was associated with a very low rate of recurrence at 30 months. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
PET/MRI: Where Might It Replace PET/CT?
Ehman, Eric C.; Johnson, Geoffrey B.; Villanueva-Meyer, Javier E.; Cha, Soonmee; Leynes, Andrew Palmera; Larson, Peder Eric Zufall; Hope, Thomas A.
2017-01-01
Simultaneous positron emission tomography and MRI (PET/MRI) is a technology that combines the anatomic and quantitative strengths of MR imaging with physiologic information obtained from PET. PET and computed tomography (PET/ CT) performed in a single scanning session is an established technology already in widespread and accepted use worldwide. Given the higher cost and complexity of operating and interpreting the studies obtained on a PET/MRI system, there has been question as to which patients would benefit most from imaging with PET/MRI versus PET/CT. In this article, we compare PET/MRI with PET/CT, detail the applications for which PET/MRI has shown promise and discuss impediments to future adoption. It is our hope that future work will prove the benefit of PET/MRI to specific groups of patients, initially those in which PET/CT and MRI are already performed, leveraging simultaneity and allowing for greater degrees of multiparametric evaluation. PMID:28370695
Performance evaluation of a modular detector unit for X-ray computed tomography.
Guo, Zhe; Tang, Zhiwei; Wang, Xinzeng; Deng, Mingliang; Hu, Guangshu; Zhang, Hui
2013-04-18
A research prototype CT scanner is currently under development in our lab. One of the key components in this project is the CT detector. This paper describes the design and performance evaluation of the modular CT detector unit for our proposed scanner. It consists of a Photodiode Array Assembly which captures irradiating X-ray photons and converts the energy into electrical current, and a mini Data Acquisition System which performs current integration and converts the analog signal into digital samples. The detector unit can be easily tiled together to form a CT detector. Experiments were conducted to characterize the detector performance both at the single unit level and system level. The noise level, linearity and uniformity of the proposed detector unit were reported and initial imaging studies were also presented which demonstrated the potential application of the proposed detector unit in actual CT scanners.
Konecki, Dariusz; Grabowska-Derlatka, Laretta; Pacho, Ryszard; Rowiński, Olgierd
2017-01-01
Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding.
Assessment of imaging quality in magnified phase CT of human bone tissue at the nanoscale
NASA Astrophysics Data System (ADS)
Yu, Boliang; Langer, Max; Pacureanu, Alexandra; Gauthier, Remy; Follet, Helene; Mitton, David; Olivier, Cecile; Cloetens, Peter; Peyrin, Francoise
2017-10-01
Bone properties at all length scales have a major impact on the fracture risk in disease such as osteoporosis. However, quantitative 3D data on bone tissue at the cellular scale are still rare. Here we propose to use magnified X-ray phase nano-CT to quantify bone ultra-structure in human bone, on the new setup developed on the beamline ID16A at the ESRF, Grenoble. Obtaining 3D images requires the application of phase retrieval prior to tomographic reconstruction. Phase retrieval is an ill-posed problem for which various approaches have been developed. Since image quality has a strong impact on the further quantification of bone tissue, our aim here is to evaluate different phase retrieval methods for imaging bone samples at the cellular scale. Samples from femurs of female donors were scanned using magnified phase nano-CT at voxel sizes of 120 and 30 nm with an energy of 33 keV. Four CT scans at varying sample-to-detector distances were acquired for each sample. We evaluated three phase retrieval methods adapted to these conditions: Paganin's method at single distance, Paganin's method extended to multiple distances, and the contrast transfer function (CTF) approach for pure phase objects. These methods were used as initialization to an iterative refinement step. Our results based on visual and quantitative assessment show that the use of several distances (as opposed to single one) clearly improves image quality and the two multi-distance phase retrieval methods give similar results. First results on the segmentation of osteocyte lacunae and canaliculi from such images are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozaki, Toshiro, E-mail: ganronbun@amail.plala.or.jp; Seki, Hiroshi; Shiina, Makoto
2009-09-15
The purpose of the present study was to elucidate a method for predicting the intrahepatic arteriovenous shunt rate from computed tomography (CT) images and biochemical data, instead of from arterial perfusion scintigraphy, because adverse exacerbated systemic effects may be induced in cases where a high shunt rate exists. CT and arterial perfusion scintigraphy were performed in patients with liver metastases from gastric or colorectal cancer. Biochemical data and tumor marker levels of 33 enrolled patients were measured. The results were statistically verified by multiple regression analysis. The total metastatic hepatic tumor volume (V{sub metastasized}), residual hepatic parenchyma volume (V{sub residual};more » calculated from CT images), and biochemical data were treated as independent variables; the intrahepatic arteriovenous (IHAV) shunt rate (calculated from scintigraphy) was treated as a dependent variable. The IHAV shunt rate was 15.1 {+-} 11.9%. Based on the correlation matrixes, the best correlation coefficient of 0.84 was established between the IHAV shunt rate and V{sub metastasized} (p < 0.01). In the multiple regression analysis with the IHAV shunt rate as the dependent variable, the coefficient of determination (R{sup 2}) was 0.75, which was significant at the 0.1% level with two significant independent variables (V{sub metastasized} and V{sub residual}). The standardized regression coefficients ({beta}) of V{sub metastasized} and V{sub residual} were significant at the 0.1 and 5% levels, respectively. Based on this result, we can obtain a predicted value of IHAV shunt rate (p < 0.001) using CT images. When a high shunt rate was predicted, beneficial and consistent clinical monitoring can be initiated in, for example, hepatic arterial infusion chemotherapy.« less
Automated quantitative 3D analysis of aorta size, morphology, and mural calcification distributions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurugol, Sila, E-mail: sila.kurugol@childrens.harvard.edu; Come, Carolyn E.; Diaz, Alejandro A.
Purpose: The purpose of this work is to develop a fully automated pipeline to compute aorta morphology and calcification measures in large cohorts of CT scans that can be used to investigate the potential of these measures as imaging biomarkers of cardiovascular disease. Methods: The first step of the automated pipeline is aorta segmentation. The algorithm the authors propose first detects an initial aorta boundary by exploiting cross-sectional circularity of aorta in axial slices and aortic arch in reformatted oblique slices. This boundary is then refined by a 3D level-set segmentation that evolves the boundary to the location of nearbymore » edges. The authors then detect the aortic calcifications with thresholding and filter out the false positive regions due to nearby high intensity structures based on their anatomical location. The authors extract the centerline and oblique cross sections of the segmented aortas and compute the aorta morphology and calcification measures of the first 2500 subjects from COPDGene study. These measures include volume and number of calcified plaques and measures of vessel morphology such as average cross-sectional area, tortuosity, and arch width. Results: The authors computed the agreement between the algorithm and expert segmentations on 45 CT scans and obtained a closest point mean error of 0.62 ± 0.09 mm and a Dice coefficient of 0.92 ± 0.01. The calcification detection algorithm resulted in an improved true positive detection rate of 0.96 compared to previous work. The measurements of aorta size agreed with the measurements reported in previous work. The initial results showed associations of aorta morphology with calcification and with aging. These results may indicate aorta stiffening and unwrapping with calcification and aging. Conclusions: The authors have developed an objective tool to assess aorta morphology and aortic calcium plaques on CT scans that may be used to provide information about the presence of cardiovascular disease and its clinical impact in smokers.« less
Automated quantitative 3D analysis of aorta size, morphology, and mural calcification distributions
Kurugol, Sila; Come, Carolyn E.; Diaz, Alejandro A.; Ross, James C.; Kinney, Greg L.; Black-Shinn, Jennifer L.; Hokanson, John E.; Budoff, Matthew J.; Washko, George R.; San Jose Estepar, Raul
2015-01-01
Purpose: The purpose of this work is to develop a fully automated pipeline to compute aorta morphology and calcification measures in large cohorts of CT scans that can be used to investigate the potential of these measures as imaging biomarkers of cardiovascular disease. Methods: The first step of the automated pipeline is aorta segmentation. The algorithm the authors propose first detects an initial aorta boundary by exploiting cross-sectional circularity of aorta in axial slices and aortic arch in reformatted oblique slices. This boundary is then refined by a 3D level-set segmentation that evolves the boundary to the location of nearby edges. The authors then detect the aortic calcifications with thresholding and filter out the false positive regions due to nearby high intensity structures based on their anatomical location. The authors extract the centerline and oblique cross sections of the segmented aortas and compute the aorta morphology and calcification measures of the first 2500 subjects from COPDGene study. These measures include volume and number of calcified plaques and measures of vessel morphology such as average cross-sectional area, tortuosity, and arch width. Results: The authors computed the agreement between the algorithm and expert segmentations on 45 CT scans and obtained a closest point mean error of 0.62 ± 0.09 mm and a Dice coefficient of 0.92 ± 0.01. The calcification detection algorithm resulted in an improved true positive detection rate of 0.96 compared to previous work. The measurements of aorta size agreed with the measurements reported in previous work. The initial results showed associations of aorta morphology with calcification and with aging. These results may indicate aorta stiffening and unwrapping with calcification and aging. Conclusions: The authors have developed an objective tool to assess aorta morphology and aortic calcium plaques on CT scans that may be used to provide information about the presence of cardiovascular disease and its clinical impact in smokers. PMID:26328995
Ruan, Leilei; Philip Robertson, G
2013-08-01
Around 4.4 million ha of land in USDA Conservation Reserve Program (CRP) contracts will expire between 2013 and 2018 and some will likely return to crop production. No-till (NT) management offers the potential to reduce the global warming costs of CO2 , CH4 , and N2 O emissions during CRP conversion, but to date there have been no CRP conversion tillage comparisons. In 2009, we converted portions of three 9-21 ha CRP fields in Michigan to conventional tillage (CT) or NT soybean production and reserved a fourth field for reference. Both CO2 and N2 O fluxes increased following herbicide application in all converted fields, but in the CT treatment substantial and immediate N2 O and CO2 fluxes occurred after tillage. For the initial 201-day conversion period, average daily N2 O fluxes (g N2 O-N ha(-1) d(-1) ) were significantly different in the order: CT (47.5 ± 6.31, n = 6) ≫ NT (16.7 ± 2.45, n = 6) ≫ reference (2.51 ± 0.73, n = 4). Similarly, soil CO2 fluxes in CT were 1.2 times those in NT and 3.1 times those in the unconverted CRP reference field. All treatments were minor sinks for CH4 (-0.69 ± 0.42 to -1.86 ± 0.37 g CH4 -C ha(-1) d(-1) ) with no significant differences among treatments. The positive global warming impact (GWI) of converted soybean fields under both CT (11.5 Mg CO2 e ha(-1) ) and NT (2.87 Mg CO2 e ha(-1) ) was in contrast to the negative GWI of the unconverted reference field (-3.5 Mg CO2 e ha(-1) ) with on-going greenhouse gas (GHG) mitigation. N2 O contributed 39.3% and 55.0% of the GWI under CT and NT systems with the remainder contributed by CO2 (60.7% and 45.0%, respectively). Including foregone mitigation, we conclude that NT management can reduce GHG costs by ~60% compared to CT during initial CRP conversion. © 2013 John Wiley & Sons Ltd.
Haeussler, Silvia; Luepke, Matthias; Seifert, Hermann; Staszyk, Carsten
2014-02-21
In equine practice, teeth corrections by means of motorized grinding systems are standard procedure. The heat resulting from that treatment may cause irreparable damage to the dental pulp. It has been shown that a 5.5°C temperature rise may cause severe destruction in pulp cells. Hence, the capability to continuously form secondary dentine is lost, and may lead, due to equine-typical occlusal tooth abrasion, to an opening of the pulp cavity.To obtain reliable data on the intra-pulp increase in temperature during corrective treatments, equine cheek teeth (CT) were modified in a way (occlusal surface smoothed, apical parts detached, pulp horns standardized) that had been qualified in own former published studies. All parameters influencing the grinding process were standardized (force applied, initial temperatures, dimensions of pulp horns, positioning of grinding disk, rotational speed). During grinding experiments, imitating real dental treatments, the time span for an intra-pulp temperature increase of 5.5°C was determined. The minimum time recorded for an intra-pulp temperature increase of 5.5°C was 38 s in mandibular CT (buccal grinding, 12,000 rpm) and 70 s in maxillary CT (flat occlusal grinding, 12,000 rpm). The data obtained showed that doubling the rotational speed of the disk results in halving the time span after which the critical intra-pulp temperature increase in maxillary CT is reached. For mandibular CT, the time span even drops by two thirds. The use of standardized hypsodont CT enabled comparative studies of intra-pulp heating during the grinding of occlusal tooth surfaces using different tools and techniques. The anatomical structure of the natural vital hypsodont tooth must be kept in mind, so that the findings of this study do not create a deceptive sense of security with regard to the time-dependent heating of the native pulp.
Comi, Giancarlo; Cook, Stuart; Rammohan, Kottil; Soelberg Sorensen, Per; Vermersch, Patrick; Adeniji, Abidemi K.; Dangond, Fernando; Giovannoni, Gavin
2018-01-01
Background The CLARITY and CLARITY Extension studies demonstrated that treatment of relapsing–remitting multiple sclerosis (RRMS) with cladribine tablets (CT) results in significant clinical improvements, compared with placebo. This paper presents the key magnetic resonance imaging (MRI) findings from the CLARITY Extension study. Methods Patients who received a cumulative dose of either CT 3.5 or 5.25 mg/kg in CLARITY were rerandomized to either placebo or CT 3.5 mg/kg in CLARITY Extension. Patients from the arm that received placebo in CLARITY were assigned to CT 3.5 mg/kg. MRI assessments were carried out when patients entered CLARITY Extension and after Weeks 24, 48, 72 and 96, and in a supplemental follow-up period. Results At CLARITY Extension baseline, patients who received placebo during CLARITY had more T1 gadolinium-enhanced (Gd+) lesions than patients who received CT during CLARITY. These patients, who were then exposed to cladribine 3.5 mg/kg during the extension, experienced a 90.4% relative reduction (median difference −0.33, 97.5% confidence interval −0.33–0.00; p < 0.001) in T1 Gd+ lesions at the end of the extension compared with the end of CLARITY. Overall, the majority of patients in each treatment group remained free from T1 Gd+ lesions throughout CLARITY Extension. However, a small proportion of patients who were treated with cladribine in CLARITY and received placebo in CLARITY Extension showed evidence of increased MRI activity, and this was associated with a prolonged treatment gap between CLARITY and CLARITY Extension. Conclusion A 2-year treatment with CT 3.5 mg/kg has a durable effect on MRI outcomes in the majority of patients, an effect that was sustained in patients who were not retreated in the subsequent 2 years after initial treatment. ClinicalTrials.gov identifier: NCT00641537 PMID:29399054
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neylon, J; Min, Y; Qi, S
2014-06-15
Purpose: Deformable image registration (DIR) plays a pivotal role in head and neck adaptive radiotherapy but a systematic validation of DIR algorithms has been limited by a lack of quantitative high-resolution groundtruth. We address this limitation by developing a GPU-based framework that provides a systematic DIR validation by generating (a) model-guided synthetic CTs representing posture and physiological changes, and (b) model-guided landmark-based validation. Method: The GPU-based framework was developed to generate massive mass-spring biomechanical models from patient simulation CTs and contoured structures. The biomechanical model represented soft tissue deformations for known rigid skeletal motion. Posture changes were simulated by articulatingmore » skeletal anatomy, which subsequently applied elastic corrective forces upon the soft tissue. Physiological changes such as tumor regression and weight loss were simulated in a biomechanically precise manner. Synthetic CT data was then generated from the deformed anatomy. The initial and final positions for one hundred randomly-chosen mass elements inside each of the internal contoured structures were recorded as ground truth data. The process was automated to create 45 synthetic CT datasets for a given patient CT. For instance, the head rotation was varied between +/− 4 degrees along each axis, and tumor volumes were systematically reduced up to 30%. Finally, the original CT and deformed synthetic CT were registered using an optical flow based DIR. Results: Each synthetic data creation took approximately 28 seconds of computation time. The number of landmarks per data set varied between two and three thousand. The validation method is able to perform sub-voxel analysis of the DIR, and report the results by structure, giving a much more in depth investigation of the error. Conclusions: We presented a GPU based high-resolution biomechanical head and neck model to validate DIR algorithms by generating CT equivalent 3D volumes with simulated posture changes and physiological regression.« less
SU-E-T-574: Fessiblity of Using the Calypso System for HDR Interstitial Catheter Reconstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, J S; Ma, C
2014-06-01
Purpose: It is always a challenge to reconstruct the interstitial catheter for high dose rate (HDR) brachytherapy on patient CT or MR images. This work aims to investigate the feasibility of using the Calypso system (Varian Medical, CA) for HDR catheter reconstruction utilizing its accuracy on tracking the electromagnetic transponder location. Methods: Experiment was done with a phantom that has a HDR interstitial catheter embedded inside. CT scan with a slice thickness of 1.25 mm was taken for this phantom with two Calypso beacon transponders in the catheter. The two transponders were connected with a wire. The Calypso system wasmore » used to record the beacon transponders’ location in real time when they were gently pulled out with the wire. The initial locations of the beacon transponders were used for registration with the CT image and the detected transponder locations were used for the catheter path reconstruction. The reconstructed catheter path was validated on the CT image. Results: The HDR interstitial catheter was successfully reconstructed based on the transponders’ coordinates recorded by the Calypso system in real time when the transponders were pulled in the catheter. After registration with the CT image, the shape and location of the reconstructed catheter are evaluated against the CT image and the result shows an accuracy of 2 mm anywhere in the Calypso detectable region which is within a 10 cm X 10 cm X 10 cm cubic box for the current system. Conclusion: It is feasible to use the Calypso system for HDR interstitial catheter reconstruction. The obstacle for its clinical usage is the size of the beacon transponder whose diameter is bigger than most of the interstitial catheters used in clinic. Developing smaller transponders and supporting software and hardware for this application is necessary before it can be adopted for clinical use.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balik, S; Weiss, E; Sleeman, W
Purpose: To evaluate the potential impact of several setup error correction strategies on a proposed image-guided adaptive radiotherapy strategy for locally advanced lung cancer. Methods: Daily 4D cone-beam CT and weekly 4D fan-beam CT images were acquired from 9 lung cancer patients undergoing concurrent chemoradiation therapy. Initial planning CT was deformably registered to daily CBCT images to generate synthetic treatment courses. An adaptive radiation therapy course was simulated using the weekly CT images with replanning twice and a hypofractionated, simultaneous integrated boost to a total dose of 66 Gy to the original PTV and either a 66 Gy (no boost)more » or 82 Gy (boost) dose to the boost PTV (ITV + 3mm) in 33 fractions with IMRT or VMAT. Lymph nodes (LN) were not boosted (prescribed to 66 Gy in both plans). Synthetic images were rigidly, bony (BN) or tumor and carina (TC), registered to the corresponding plan CT, dose was computed on these from adaptive replans (PLAN) and deformably accumulated back to the original planning CT. Cumulative D98% of CTV of PT (ITV for 82Gy) and LN, and normal tissue dose changes were analyzed. Results: Two patients were removed from the study due to large registration errors. For the remaining 7 patients, D98% for CTV-PT (ITV-PT for 82 Gy) and CTV-LN was within 1 Gy of PLAN for both 66 Gy and 82 Gy plans with both setup techniques. Overall, TC based setup provided better results, especially for LN coverage (p = 0.1 for 66Gy plan and p = 0.2 for 82 Gy plan, comparison of BN and TC), though not significant. Normal tissue dose constraints violated for some patients if constraint was barely achieved in PLAN. Conclusion: The hypofractionated adaptive strategy appears to be deliverable with soft tissue alignment for the evaluated margins and planning parameters. Research was supported by NIH P01CA116602.« less
Hoshiko, Sumi; Smith, Daniel; Fan, Cathyn; Jones, Carrie R; McNeel, Sandra V; Cohen, Ronald A
2014-05-01
Radiation exposure from medical sources now equals or exceeds that from natural background sources, largely attributable to a 20-fold increase in CT use since 1980. Increasing exposure to children and fetuses is of most concern due to their heightened susceptibility. More recently, CT use may be leveling or decreasing, but it is unclear whether this change is widespread or varies by type of institution. We sought to characterize trends in CT utilization in California hospitals and emergency departments among children and pregnant women, looking at different types of facilities, such as teaching, private, public and nonprofit institutions. We examined frequency of CT examinations by year from 229 facilities reporting CT usage in routinely collected California statewide data for 2005-2012. We modeled trends overall and by facility type. CT scans for pediatric and pregnant patient visits in the emergency department increased initially, then started to decline after 2008. Among hospital admissions, rates declined or leveled after 2005. In the emergency department, CT rates varied between types of facilities, with teaching hospitals reducing use sooner and more sharply than other types of facilities. CT utilization in California among children and pregnant women has begun to level or decline. Still, population exposure remains at historically high levels, warranting consideration of potential public health implications. Further examination of reasons for trends among hospital types, particularly how teaching hospitals have reduced rates of CT utilization, may help identify strategies for CT reduction without compromising patient care.
Diagnosis and treatment of mesenteric volvulus in a red kangaroo (Macropus rufus).
Knafo, S Emmanuelle; Rosenblatt, Alana J; Morrisey, James K; Flanders, James A; Thompson, Margret S; Knapp-Hoch, Heather M
2014-04-01
An 8-year-old male red kangaroo (Macropus rufus) was evaluated with a 2-week history of vomiting and anorexia. Four days prior, the patient became refractory to medical management. The kangaroo was admitted for diagnostic testing and treatment including whole body CT, blood work, and emergency laparotomy. CT findings of a severely enlarged stomach, splenic displacement, and a whirl sign were indicative of mesenteric volvulus with gastric dilatation-volvulus (GDV). Contrast enhancement of abdominal viscera suggested intact arterial blood supply; however, compression of the caudal vena cava and portal vein indicated venous obstruction. Results of preoperative blood work suggested biliary stasis without evidence of inflammation. Additionally, a tooth root abscess was diagnosed on the basis of results of CT. Exploratory laparotomy confirmed the diagnosis of mesenteric volvulus and GDV. The volvuli were corrected by clockwise derotation, and a gastropexy was performed. Tissue samples were obtained from the spleen and liver for evaluation. The kangaroo recovered from surgery, and the abscessed tooth was extracted 6 days later. Eight days after initial evaluation, the kangaroo was discharged. In the present report, the CT whirl sign was used to diagnose volvulus of the abdominal viscera, which suggests that this diagnostic indicator has utility in veterinary patients. Mesenteric volvulus with GDV was successfully treated in a nondomestic species. The tooth root abscess, a common condition in macropods, may explain the historic episodes of anorexia reported by the owner and may have contributed to the development of mesenteric volvulus and GDV in this kangaroo.
Classifying features in CT imagery: accuracy for some single- and multiple-species classifiers
Daniel L. Schmoldt; Jing He; A. Lynn Abbott
1998-01-01
Our current approach to automatically label features in CT images of hardwood logs classifies each pixel of an image individually. These feature classifiers use a back-propagation artificial neural network (ANN) and feature vectors that include a small, local neighborhood of pixels and the distance of the target pixel to the center of the log. Initially, this type of...
Radiological review of pleural tumors
Sureka, Binit; Thukral, Brij Bhushan; Mittal, Mahesh Kumar; Mittal, Aliza; Sinha, Mukul
2013-01-01
Tumors of the pleura are not uncommon and diagnosis is clinched by combined imaging and clinical correlation. Malignant tumors are more common than benign tumors. Initial imaging modalities are chest radiography and Computed Tomography (CT). Further characterization may be required using Ultrasoundgraphy (USG), Magnetic resonance Imaging (MRI) and PET-CT. Biopsy remains gold standard. This article highlights various common and uncommon tumors of pleura and characteristic imaging findings. PMID:24604935
Clinical and Organizational Factors in the Initial Evaluation of Patients With Lung Cancer
Jim Yeung, Sai-Ching; Tanoue, Lynn T.; Gould, Michael K.
2013-01-01
Background: This guideline is intended to provide an evidence-based approach to the initial evaluation of patients with known or suspected lung cancer. It also includes an assessment of the impact of timeliness of care and multidisciplinary teams on outcome. Methods: The applicable current medical literature was identified by a computerized search and evaluated using standardized methods. Recommendations were framed using the approach described by the Guidelines Oversight Committee of the American College of Chest Physicians. Data sources included MEDLINE and the Cochrane Database of Systematic Reviews. Results: Initial evaluation should include a thorough history and physical examination; CT imaging; pulmonary function tests; and hemoglobin, electrolyte, liver function, and calcium levels. Additional testing for distant metastases and paraneoplastic syndromes should be determined on the basis of these results. Paraneoplastic syndromes may have an adverse impact on cancer treatment, so they should be controlled rapidly with the goal of proceeding with definitive cancer treatment in a timely manner. Although the relationship between timeliness of care and survival is difficult to quantify, efforts to deliver timely care are reasonable and should be balanced with the need to attend to other dimensions of health-care quality (eg, safety, effectiveness, efficiency, equality, consistency with patient values and preferences). Quality care will require multiple disciplines. Although it is difficult to assess the impact, we suggest that a multidisciplinary team approach to care be used, particularly for patients requiring multimodality therapy. Conclusions: The initial evaluation of patients with lung cancer should include a thorough history and physical examination, pulmonary function tests, CT imaging, basic laboratory tests, and selective testing for distant metastases and paraneoplastic syndromes. PMID:23649435
Radiation dose from initial trauma assessment and resuscitation: review of the literature.
Hui, Catherine M; MacGregor, John H; Tien, Homer C; Kortbeek, John B
2009-04-01
Trauma care benefits from the use of imaging technologies. Trauma patients and trauma team members are exposed to radiation during the continuum of care. Knowledge of exposure amounts and effects are important for trauma team members. We performed a review of the published literature; keywords included "trauma," "patients," "trauma team members," "wounds," "injuries," "radiation," "exposure," "dose" and "computed tomography" (CT). We also reviewed the Board on Radiation Effects Research (BEIR VII) report, published in 2005 and 2006. We found no randomized controlled trials or studies. Relevant studies demonstrated that CT accounts for the single largest radiation exposure in trauma patients. Exposure to 100 mSv could result in a solid organ cancer or leukemia in 1 of 100 people. Trauma team members do not exceed the acceptable occupation radiation exposure determined by the National Council of Radiation Protection and Management. Modern imaging technologies such as 16- and 64-slice CT scanners may decrease radiation exposure. Multiple injured trauma patients receive a substantial dose of radiation. Radiation exposure is cumulative. The low individual risk of cancer becomes a greater public health issue when multiplied by a large number of examinations. Though CT scans are an invaluable resource and are becoming more easily accessible, they should not replace careful clinical examination and should be used only in appropriate patients.
Spendrup, Sara; Hunter, Erik; Isgren, Ellinor
2016-05-01
Nature sounds are increasingly used by some food retailers to enhance in-store ambiance and potentially even influence sustainable food choices. An in-store, 2 × 3 between-subject full factorial experiment conducted on 627 customers over 12 days tested whether nature sound directly and indirectly influenced willingness to buy (WTB) sustainable foods. The results show that nature sounds positively and directly influence WTB organic foods in groups of customers (men) that have relatively low initial intentions to buy. Indirectly, we did not find support for the effect of nature sound on influencing mood or connectedness to nature (CtN). However, we show that information on the product's sustainability characteristics moderates the relationship between CtN and WTB in certain groups. Namely, when CtN is high, sustainability information positively moderated WTB both organic and climate friendly foods in men. Conversely, when CtN was low, men expressed lower WTB organic and climate friendly foods than identical, albeit conventionally labelled products. Consequently, our study concludes that nature sounds might be an effective, yet subtle in-store tool to use on groups of consumers who might otherwise respond negatively to more overt forms of sustainable food information. Copyright © 2016 Elsevier Ltd. All rights reserved.
Origin and evolution of Andigena potatoes revealed by chloroplast and nuclear DNA markers.
Sukhotu, Thitaporn; Hosaka, Kazuyoshi
2006-06-01
Andigena potatoes (Solanum tuberosum L. subsp. andigena Hawkes) (2n = 4x = 48) are important, native-farmer-selected cultivars in the Andes, which form a primary gene pool for improving a worldwide grown potato (S. tuberosum subsp. tuberosum). To elucidate the origin of Andigena, 196 Andigena accessions were compared with 301 accessions of 33 closely related cultivated and wild species using several types of chloroplast DNA (ctDNA) markers and nuclear DNA (nDNA) restriction fragment length polymorphism (RFLP) markers. Fourteen ctDNA types (haplotypes) and 115 RFLP bands were detected in Andigena, of which the main haplotypes and frequent RFLP bands were mostly shared with a cultivated diploid species, S. stenotomum Juz. et Buk. Principal component analysis of nDNA polymorphisms revealed a progressive and continuous variation from Peruvian wild species with C-type ctDNA to a group of wild species having S-type ctDNA in its variation range (S. bukasovii, S. canasense, S. candolleanum, and S. multidissectum), to cultivated diploid potatoes (S. phureja and S. stenotomum), and to cultivated tetraploid potatoes (Andigena and Chilean S. tuberosum subsp. tuberosum). These results suggest that the initial Andigena population arose with multiple origins exclusively from S. stenotomum. The overall evolutionary process toward the present-day Andigena was discussed.
CT-Guided Interventions Using a Free-Hand, Optical Tracking System: Initial Clinical Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schubert, Tilman, E-mail: TSchubert@uhbs.ch; Jacob, Augustinus L.; Pansini, Michele
2013-08-01
PurposeThe present study was designed to evaluate the geometrical accuracy and clinical applicability of a new, free-hand, CT-guided, optical navigation system.MethodsFifteen procedures in 14 consecutive patients were retrospectively analyzed. The navigation system was applied for interventional procedures on small target lesions, in cases with long needle paths, narrow access windows, or when an out-of-plane access was expected. Mean lesion volume was 27.9 ml, and mean distance to target measured was 107.5 mm. Eleven of 15 needle trajectories were planned as out-of-plane approaches regarding the axial CT plane.ResultsNinety-one percent of the biopsies were diagnostic. All therapeutic interventions were technically successful. Targetingmore » precision was high with a mean distance of the needle tip from planned target of 1.98 mm. Mean intervention time was 1:12 h. A statistically significant correlation between angular needle deviation and intervention time (p = 0.007), respiratory movement of the target (p = 0.008), and body mass index (p = 0.02) was detected. None of the evaluated parameters correlated significantly with the distance from the needle tip to the planned target.ConclusionsThe application of a navigation system for complex CT-guided procedures provided safe and effective targeting within a reasonable intervention time in our series.« less
A simple football injury leading to a grade 4 renal trauma.
Fanning, Deirdre Mary; Forde, James C; Mohan, Ponnusamy
2012-03-08
This case highlights the need for cautious management and serial regular examination of trauma patients. A 22-year-old Caucasian male presented to the emergency department 4 h following an injury sustained during football training. He complained of the immediate onset of severe left upper quadrant and left flank pain. He subsequently developed frank haematuria. On initial review, he was haemodynamically stable. CT of the abdomen and pelvis showed a grade 4 renal trauma. Over the following 36 h, he remained haemodynamically stable. On serial abdominal examinations however, he developed a rigid abdomen and was noted to have a haemoglobin drop. Interval CT scan showed a progression of his injury and the presence of a haemoperitoneum. An emergency laparotomy was performed resulting in a left nephrectomy. He made an uneventful recovery.
The role of marshall and rotterdam score in predicting 30-day outcome of traumatic brain injury
NASA Astrophysics Data System (ADS)
Siahaan, A. M. P.; Akbar, T. Y. M.; Nasution, M. D.
2018-03-01
Traumatic brain injury (TBI) remains one of the leading causes of mortality and morbidity, especially in the young population. To predict the outcome of TBI, Marshall, and Rotterdam–CT Scan based scoring was mostly used. As many studies showed conflicting results regarding of the usage of both scoring, this study aims to determine the correlation between Rotterdam and Marshall scoring system with outcome in 30 days and found correlation among them. In 120 subjects with TBI that admitted to Adam Malik General Hospital, we found a significant association of both scorings with the 30-day Glasgow Outcome Score. Therefore, we recommend the use of Marshall and Rotterdam CT Score in initial assessment as a good predictor for patients with TBI.
Non-operative management of blunt splenic injuries in a paediatric population: a 12-year experience.
Kirkegård, Jakob; Avlund, Tue Højslev; Amanavicius, Nerijus; Mortensen, Frank Viborg; Kissmeyer-Nielsen, Peter
2015-02-01
Non-operative management (NOM) is now the primary treatment for blunt splenic injuries in children. Only one study has examined the use of NOM in a Scandinavian population. Thus, the purpose of this study is to report our experience in treating children with blunt splenic injuries with NOM at a Danish university hospital. We conducted a retrospective observational study of 34 consecutive children (aged 16 years or less) admitted to our level 1-trauma centre with blunt splenic injury in the 12-year period from 1 January 2001 to 31 December 2012. Data on patients and procedures were obtained by review of all medical records and re-evaluation of all initial computed tomographies (CT). We included 34 children with a median age of 10.5 years (67.6% males) in this study. All patients were scheduled for NOM, and two (5.9%) patients underwent splenic artery embolisation (SAE). Two (5.9%) patients later needed surgical intervention. The NOM success rate was 88% (95% confidence interval (CI): 73-97%) without SAE and 94% (95% CI: 80-99%) with SAE. We found no difference in the American Association for the Surgery of Trauma grade when comparing the initial CT evaluation (mean 2.59 ± 1.1) with the CT re-evaluation (mean 2.71 ± 0.94); p = 0.226. We demonstrated a high degree of success and safety of non-operative treatment in children with blunt splenic injury in a Scandinavian setting. Our results are comparable to international findings.
Richmond, N D; Pilling, K E; Peedell, C; Shakespeare, D; Walker, C P
2012-01-01
Stereotactic body radiotherapy for early stage non-small cell lung cancer is an emerging treatment option in the UK. Since relatively few high-dose ablative fractions are delivered to a small target volume, the consequences of a geometric miss are potentially severe. This paper presents the results of treatment delivery set-up data collected using Elekta Synergy (Elekta, Crawley, UK) cone-beam CT imaging for 17 patients immobilised using the Bodyfix system (Medical Intelligence, Schwabmuenchen, Germany). Images were acquired on the linear accelerator at initial patient treatment set-up, following any position correction adjustments, and post-treatment. These were matched to the localisation CT scan using the Elekta XVI software. In total, 71 fractions were analysed for patient set-up errors. The mean vector error at initial set-up was calculated as 5.3±2.7 mm, which was significantly reduced to 1.4±0.7 mm following image guided correction. Post-treatment the corresponding value was 2.1±1.2 mm. The use of the Bodyfix abdominal compression plate on 5 patients to reduce the range of tumour excursion during respiration produced mean longitudinal set-up corrections of −4.4±4.5 mm compared with −0.7±2.6 mm without compression for the remaining 12 patients. The use of abdominal compression led to a greater variation in set-up errors and a shift in the mean value. PMID:22665927
Reduction in Chemotherapy Mixing Errors Using Six Sigma: Illinois CancerCare Experience.
Heard, Bridgette; Miller, Laura; Kumar, Pankaj
2012-03-01
Chemotherapy mixing errors (CTMRs), although rare, have serious consequences. Illinois CancerCare is a large practice with multiple satellite offices. The goal of this study was to reduce the number of CTMRs using Six Sigma methods. A Six Sigma team consisting of five participants (registered nurses and pharmacy technicians [PTs]) was formed. The team had 10 hours of Six Sigma training in the DMAIC (ie, Define, Measure, Analyze, Improve, Control) process. Measurement of errors started from the time the CT order was verified by the PT to the time of CT administration by the nurse. Data collection included retrospective error tracking software, system audits, and staff surveys. Root causes of CTMRs included inadequate knowledge of CT mixing protocol, inconsistencies in checking methods, and frequent changes in staffing of clinics. Initial CTMRs (n = 33,259) constituted 0.050%, with 77% of these errors affecting patients. The action plan included checklists, education, and competency testing. The postimplementation error rate (n = 33,376, annualized) over a 3-month period was reduced to 0.019%, with only 15% of errors affecting patients. Initial Sigma was calculated at 4.2; this process resulted in the improvement of Sigma to 5.2, representing a 100-fold reduction. Financial analysis demonstrated a reduction in annualized loss of revenue (administration charges and drug wastage) from $11,537.95 (Medicare Average Sales Price) before the start of the project to $1,262.40. The Six Sigma process is a powerful technique in the reduction of CTMRs.
Wenz, Holger; Maros, Máté E; Meyer, Mathias; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Flohr, Thomas; Leidecker, Christianne; Groden, Christoph; Scharf, Johann; Henzler, Thomas
2015-01-01
To prospectively intra-individually compare image quality of a 3rd generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3rd generation DSCT. CTDIvol identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3rd-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (p<0.05). Mean SNR was significantly higher in all spiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*Bonferroni0.05<0.0024). Subjective image quality improved with increasing IR levels. Combination of 3rd-generation DSCT spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels.
Moore, Christopher L.; Daniels, Brock; Singh, Dinesh; Luty, Seth; Gunabushanam, Gowthaman; Ghita, Monica; Molinaro, Annette; Gross, Cary P.
2016-01-01
Purpose To determine if a reduced-dose computed tomography (CT) protocol could effectively help to identify patients in the emergency department (ED) with moderate to high likelihood of calculi who would require urologic intervention within 90 days. Materials and Methods The study was approved by the institutional review board and written informed consent with HIPAA authorization was obtained. This was a prospective, single-center study of patients in the ED with moderate to high likelihood of ureteral stone undergoing CT imaging. Objective likelihood of ureteral stone was determined by using the previously derived and validated STONE clinical prediction rule, which includes five elements: sex, timing, origin, nausea, and erythrocytes. All patients with high STONE score (STONE score, 10–13) underwent reduced-dose CT, while those with moderate likelihood of ureteral stone (moderate STONE score, 6–9) underwent reduced-dose CT or standard CT based on clinician discretion. Patients were followed to 90 days after initial imaging for clinical course and for the primary outcome of any intervention. Statistics are primarily descriptive and are reported as percentages, sensitivities, and specificities with 95% confidence intervals. Results There were 264 participants enrolled and 165 reduced-dose CTs performed; of these participants, 108 underwent reduced-dose CT alone with complete follow-up. Overall, 46 of 264 (17.4%) of patients underwent urologic intervention, and 25 of 108 (23.1%) patients who underwent reduced-dose CT underwent a urologic intervention; all were correctly diagnosed on the clinical report of the reduced-dose CT (sensitivity, 100%; 95% confidence interval: 86.7%, 100%). The average dose-length product for all standard-dose CTs was 857 mGy · cm ± 395 compared with 101 mGy · cm ± 39 for all reduced-dose CTs (average dose reduction, 88.2%). There were five interventions for nonurologic causes, three of which were urgent and none of which were missed when reduced-dose CT was performed. Conclusion A CT protocol with over 85% dose reduction can be used in patients with moderate to high likelihood of ureteral stone to safely and effectively identify patients in the ED who will require urologic intervention. PMID:26943230
Imaging Characteristics of Children with Auditory Neuropathy Spectrum Disorder
Roche, Joseph P.; Huang, Benjamin Y.; Castillo, Mauricio; Bassim, Marc K.; Adunka, Oliver F.; Buchman, Craig A.
2013-01-01
Objective To identify and define the imaging characteristics of children with auditory neuropathy spectrum disorder (ANSD). Design Retrospective medical records review and analysis of both temporal bone computed tomography (CT) and magnetic resonance images (MRI) in from children with the diagnosis of ANSD. Setting Tertiary referral center. Patients 118 children with the electrophysiological characteristics of ANSD with available imaging studies for review. Interventions Two neuroradiologists and a neurotologist reviewed each study and consensus descriptions were established. Main outcome measures The type and number of imaging findings were tabulated. Results Sixty-eight (64%) MRIs revealed at least one imaging abnormality while selective use of CT identified 23 (55%) with anomalies. The most prevalent MRI findings included cochlear nerve deficiency (n=51; 28% of 183 nerves), brain abnormalities (n=42; 40% of 106 brains) and prominent temporal horns (n=33, 16% of 212 temporal lobes). The most prevalent CT finding from selective use of CT was cochlear dysplasia (n=13; 31%). Conclusions MRI will identify many abnormalities in children with ANSD that are not readily discernable on CT. Specifically, both developmental and acquired abnormalities of the brain, posterior cranial fossa, and cochlear nerves are not uncommonly seen in this patient population. Inner ear anomalies are well delineated using either imaging modality. Since many of the central nervous system findings identified in this study using MRI can alter the treatment and prognosis for these children, we believe that MRI should be the initial imaging study of choice for children with ANSD. PMID:20593543
NASA Astrophysics Data System (ADS)
Chen, Bin; Kitasaka, Takayuki; Honma, Hirotoshi; Takabatake, Hirotsugu; Mori, Masaki; Natori, Hiroshi; Mori, Kensaku
2012-03-01
This paper presents a solitary pulmonary nodule (SPN) segmentation method based on local intensity structure analysis and neighborhood feature analysis in chest CT images. Automated segmentation of SPNs is desirable for a chest computer-aided detection/diagnosis (CAS) system since a SPN may indicate early stage of lung cancer. Due to the similar intensities of SPNs and other chest structures such as blood vessels, many false positives (FPs) are generated by nodule detection methods. To reduce such FPs, we introduce two features that analyze the relation between each segmented nodule candidate and it neighborhood region. The proposed method utilizes a blob-like structure enhancement (BSE) filter based on Hessian analysis to augment the blob-like structures as initial nodule candidates. Then a fine segmentation is performed to segment much more accurate region of each nodule candidate. FP reduction is mainly addressed by investigating two neighborhood features based on volume ratio and eigenvector of Hessian that are calculates from the neighborhood region of each nodule candidate. We evaluated the proposed method by using 40 chest CT images, include 20 standard-dose CT images that we randomly chosen from a local database and 20 low-dose CT images that were randomly chosen from a public database: LIDC. The experimental results revealed that the average TP rate of proposed method was 93.6% with 12.3 FPs/case.
Itazawa, Tomoko; Tamaki, Yukihisa; Komiyama, Takafumi; Nishimura, Yasumasa; Nakayama, Yuko; Ito, Hiroyuki; Ohde, Yasuhisa; Kusumoto, Masahiko; Sakai, Shuji; Suzuki, Kenji; Watanabe, Hirokazu; Asamura, Hisao
2017-01-01
The purpose of this study was to develop a consensus-based computed tomographic (CT) atlas that defines lymph node stations in radiotherapy for lung cancer based on the lymph node map of the International Association for the Study of Lung Cancer (IASLC). A project group in the Japanese Radiation Oncology Study Group (JROSG) initially prepared a draft of the atlas in which lymph node Stations 1-11 were illustrated on axial CT images. Subsequently, a joint committee of the Japan Lung Cancer Society (JLCS) and the Japanese Society for Radiation Oncology (JASTRO) was formulated to revise this draft. The committee consisted of four radiation oncologists, four thoracic surgeons and three thoracic radiologists. The draft prepared by the JROSG project group was intensively reviewed and discussed at four meetings of the committee over several months. Finally, we proposed definitions for the regional lymph node stations and the consensus-based CT atlas. This atlas was approved by the Board of Directors of JLCS and JASTRO. This resulted in the first official CT atlas for defining regional lymph node stations in radiotherapy for lung cancer authorized by the JLCS and JASTRO. In conclusion, the JLCS-JASTRO consensus-based CT atlas, which conforms to the IASLC lymph node map, was established. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
Mital, Jeffrey; Lutter, Erika I; Barger, Alexandra C; Dooley, Cheryl A; Hackstadt, Ted
2015-06-26
Chlamydia trachomatis actively subverts the minus-end directed microtubule motor, dynein, to traffic along microtubule tracks to the Microtubule Organizing Center (MTOC) where it remains within a membrane bound replicative vacuole for the duration of its intracellular development. Unlike most substrates of the dynein motor, disruption of the dynactin cargo-linking complex by over-expression of the p50 dynamitin subunit does not inhibit C. trachomatis transport. A requirement for chlamydial protein synthesis to initiate this process suggests that a chlamydial product supersedes a requirement for p50 dynamitin. A yeast 2-hybrid system was used to screen the chlamydia inclusion membrane protein CT850 against a HeLa cell cDNA library and identified an interaction with the dynein light chain DYNLT1 (Tctex1). This interaction was at least partially dependent upon an (R/K-R/K-X-X-R/K) motif that is characteristic of DYNLT1 binding domains. CT850 expressed ectopically in HeLa cells localized at the MTOC and this localization is similarly dependent upon the predicted DYNLT1 binding domain. Furthermore, DYNLT1 is enriched at focal concentrations of CT850 on the chlamydial inclusion membrane that are known to interact with dynein and microtubules. Depletion of DYNLT1 disrupts the characteristic association of the inclusion membrane with centrosomes. Collectively, the results suggest that CT850 interacts with DYNLT1 to promote appropriate positioning of the inclusion at the MTOC. Published by Elsevier Inc.
Validating automatic semantic annotation of anatomy in DICOM CT images
NASA Astrophysics Data System (ADS)
Pathak, Sayan D.; Criminisi, Antonio; Shotton, Jamie; White, Steve; Robertson, Duncan; Sparks, Bobbi; Munasinghe, Indeera; Siddiqui, Khan
2011-03-01
In the current health-care environment, the time available for physicians to browse patients' scans is shrinking due to the rapid increase in the sheer number of images. This is further aggravated by mounting pressure to become more productive in the face of decreasing reimbursement. Hence, there is an urgent need to deliver technology which enables faster and effortless navigation through sub-volume image visualizations. Annotating image regions with semantic labels such as those derived from the RADLEX ontology can vastly enhance image navigation and sub-volume visualization. This paper uses random regression forests for efficient, automatic detection and localization of anatomical structures within DICOM 3D CT scans. A regression forest is a collection of decision trees which are trained to achieve direct mapping from voxels to organ location and size in a single pass. This paper focuses on comparing automated labeling with expert-annotated ground-truth results on a database of 50 highly variable CT scans. Initial investigations show that regression forest derived localization errors are smaller and more robust than those achieved by state-of-the-art global registration approaches. The simplicity of the algorithm's context-rich visual features yield typical runtimes of less than 10 seconds for a 5123 voxel DICOM CT series on a single-threaded, single-core machine running multiple trees; each tree taking less than a second. Furthermore, qualitative evaluation demonstrates that using the detected organs' locations as index into the image volume improves the efficiency of the navigational workflow in all the CT studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duan, X; Guild, J; Arbique, G
2015-06-15
Purpose To evaluate the image quality and spectral information of a spectral detector CT (SDCT) scanner using virtual monochromatic (VM) energy images. Methods The SDCT scanner (Philips Healthcare) was equipped with a dual-layer detector and spectral iterative reconstruction (IR), which generates conventional 80–140 kV polychromatic energy (PE) CT images using both detector layers, PE images from the low-energy (upper) and high-energy (lower) detector layers and VM images. A solid water phantom with iodine (2.0–20.0 mg I/ml) and calcium (50.0–600.0 mg Ca/ml) rod inserts was used to evaluate effective energy estimate (EEE) and iodine contrast to noise ratio (CNR). The EEEmore » corresponding to an insert CT number in a PE image was calculated from a CT number fit to the VM image set. Since PE image is prone to beam-hardening artifact EEE may underestimate the actual energy separation from two layers of the detector. A 30-cm-diameter water phantom was used to evaluate noise power spectrum (NPS). The phantoms were scanned at 120 and 140 kV with the same CTDIvol. Results The CT number difference for contrast inserts in VM images (50–150 keV) was 1.3±6% between 120 and 140 kV scans. The difference of EEE calculated from low- and high-energy detector images was 11.5 and 16.7 keV for 120 and 140 kV scans, respectively. The differences calculated from 140 and 100 kV conventional PE images were 12.8, and 20.1 keV from 140 and 80 kV conventional PE images. The iodine CNR increased monotonically with decreased keV. Compared to conventional PE images, the peak of NPS curves from VM images were shifted to lower frequency. Conclusion The EEE results indicates that SDCT at 120 and 140 kV may have energy separation comparable to 100/140 kV and 80/140 kV dual-kV imaging. The effects of IR on CNR and NPS require further investigation for SDCT. Author YY and AD are Philips Healthcare employees.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andersen, A; Casares-Magaz, O; Elstroem, U
Purpose: Cone-beam CT (CBCT) imaging may enable image- and dose-guided proton therapy, but is challenged by image artefacts. The aim of this study was to demonstrate the general applicability of a previously developed a priori scatter correction algorithm to allow CBCT-based proton dose calculations. Methods: The a priori scatter correction algorithm used a plan CT (pCT) and raw cone-beam projections acquired with the Varian On-Board Imager. The projections were initially corrected for bow-tie filtering and beam hardening and subsequently reconstructed using the Feldkamp-Davis-Kress algorithm (rawCBCT). The rawCBCTs were intensity normalised before a rigid and deformable registration were applied on themore » pCTs to the rawCBCTs. The resulting images were forward projected onto the same angles as the raw CB projections. The two projections were subtracted from each other, Gaussian and median filtered, and then subtracted from the raw projections and finally reconstructed to the scatter-corrected CBCTs. For evaluation, water equivalent path length (WEPL) maps (from anterior to posterior) were calculated on different reconstructions of three data sets (CB projections and pCT) of three parts of an Alderson phantom. Finally, single beam spot scanning proton plans (0–360 deg gantry angle in steps of 5 deg; using PyTRiP) treating a 5 cm central spherical target in the pCT were re-calculated on scatter-corrected CBCTs with identical targets. Results: The scatter-corrected CBCTs resulted in sub-mm mean WEPL differences relative to the rigid registration of the pCT for all three data sets. These differences were considerably smaller than what was achieved with the regular Varian CBCT reconstruction algorithm (1–9 mm mean WEPL differences). Target coverage in the re-calculated plans was generally improved using the scatter-corrected CBCTs compared to the Varian CBCT reconstruction. Conclusion: We have demonstrated the general applicability of a priori CBCT scatter correction, potentially opening for CBCT-based image/dose-guided proton therapy, including adaptive strategies. Research agreement with Varian Medical Systems, not connected to the present project.« less
Cho, S H; Sung, Y M; Kim, M S
2012-10-01
The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images.
Vigneron, C; Labeye, V; Cour, M; Hannoun, S; Grember, A; Rampon, F; Cotton, F
2016-01-01
Previous studies have shown that a loss of distinction between gray matter (GM) and white matter (WM) on unenhanced CT scans was predictive of poor outcome after cardiac arrest. The aim of this study was to identify a marker/predictor of imminent brain death. In this retrospective study, 15 brain-dead patients after anoxia and cardiac arrest were included. Patients were paired (1:1) with normal control subjects. Only patients' unenhanced CT scans performed before brain death and during the 24 hours after initial signs were analyzed. WM and GM densities were measured in predefined regions of interest (basal ganglia level, centrum semi-ovale level, high convexity level, brainstem level). At each level, GM and WM density and GM/WM ratio for brain-dead patients and normal control subjects were compared using the Wilcoxon signed-rank test. At each level, a lower GM/WM ratio and decreased GM and WM densities were observed in brain-dead patients' CT scans when compared with normal control subject CT scans. A cut-off value of 1.21 at the basal ganglia level was identified, below which brain death systematically occurred. GM/WM dedifferentiation on unenhanced CT scan is measurable before the occurrence of brain death, highlighting its importance in brain death prediction. The mechanism of GM/WM differentiation loss could be explained by the lack of oxygen caused by ischemia initially affecting the mitochondrial system. Copyright © 2016 Elsevier Inc. All rights reserved.
Hoffman, John M; Noo, Frédéric; Young, Stefano; Hsieh, Scott S; McNitt-Gray, Michael
2018-06-01
To facilitate investigations into the impacts of acquisition and reconstruction parameters on quantitative imaging, radiomics and CAD using CT imaging, we previously released an open source implementation of a conventional weighted filtered backprojection reconstruction called FreeCT_wFBP. Our purpose was to extend that work by providing an open-source implementation of a model-based iterative reconstruction method using coordinate descent optimization, called FreeCT_ICD. Model-based iterative reconstruction offers the potential for substantial radiation dose reduction, but can impose substantial computational processing and storage requirements. FreeCT_ICD is an open source implementation of a model-based iterative reconstruction method that provides a reasonable tradeoff between these requirements. This was accomplished by adapting a previously proposed method that allows the system matrix to be stored with a reasonable memory requirement. The method amounts to describing the attenuation coefficient using rotating slices that follow the helical geometry. In the initially-proposed version, the rotating slices are themselves described using blobs. We have replaced this description by a unique model that relies on tri-linear interpolation together with the principles of Joseph's method. This model offers an improvement in memory requirement while still allowing highly accurate reconstruction for conventional CT geometries. The system matrix is stored column-wise and combined with an iterative coordinate descent (ICD) optimization. The result is FreeCT_ICD, which is a reconstruction program developed on the Linux platform using C++ libraries and the open source GNU GPL v2.0 license. The software is capable of reconstructing raw projection data of helical CT scans. In this work, the software has been described and evaluated by reconstructing datasets exported from a clinical scanner which consisted of an ACR accreditation phantom dataset and a clinical pediatric thoracic scan. For the ACR phantom, image quality was comparable to clinical reconstructions as well as reconstructions using open-source FreeCT_wFBP software. The pediatric thoracic scan also yielded acceptable results. In addition, we did not observe any deleterious impact in image quality associated with the utilization of rotating slices. These evaluations also demonstrated reasonable tradeoffs in storage requirements and computational demands. FreeCT_ICD is an open-source implementation of a model-based iterative reconstruction method that extends the capabilities of previously released open source reconstruction software and provides the ability to perform vendor-independent reconstructions of clinically acquired raw projection data. This implementation represents a reasonable tradeoff between storage and computational requirements and has demonstrated acceptable image quality in both simulated and clinical image datasets. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Psychobiology of cumulative trauma: hair cortisol as a risk marker for stress exposure in women.
Morris, Matthew C; Abelson, James L; Mielock, Alyssa S; Rao, Uma
2017-07-01
Childhood trauma (CT) is associated with long-lasting alterations of the hypothalamic-pituitary-adrenal (HPA) axis and elevated risk for stress exposure in adulthood. Although HPA alterations are present in the early aftermath of trauma, it remains unclear how initial HPA activity is associated with subsequent stress exposure and whether CT exposure influences the strength and direction of this association. The present study examined prospective associations between hair cortisol content (HCC) and stress exposure from baseline to 3-month follow-up in young adult women with recent (i.e. past 3 months) exposure to interpersonal violence (IPV; i.e. physical or sexual assault) and non-traumatized controls. History of significant CT abuse or neglect was determined based on clinical cutoffs for a self-report CT measure: 12 women had abuse or neglect and recent IPV exposure (CT + IPV); 7 women had abuse or neglect but no IPV exposure (CT); 15 women had no history of trauma (NTC). HCC was computed for 3 cm sections reflecting cortisol secretion during the 3 months preceding the baseline assessment. The interaction of cumulative trauma and HCC predicted stress exposure over 3-month follow-up, controlling for baseline stress exposure and depressive symptoms. Simple slopes analyses revealed that lower baseline HCC predicted greater stress exposure in the CT + IPV group compared to the CT group; HCC was not associated with stress exposure in the NTC group. The present findings highlight the potential utility of HCC as a predictor of stress exposure for women with a history of childhood abuse or neglect, particularly in the context of recent IPV. Lay summary Adults with a history of CT show long-lasting alterations in major stress response systems, including the HPA axis. They are also more likely to experience stressful life events in adulthood. However, it is not clear how altered HPA activity influences risk for stress exposure and whether CT affects their relationship. The results from this study show that lower HPA activity (measured with hair cortisol) predicted greater stress exposure in women with CT - particularly for women who also experienced recent incidents involving physical or sexual assault.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braak, Sicco J., E-mail: sjbraak@gmail.com; Herder, Gerarda J. M., E-mail: j.herder@antoniusziekenhuis.nl; Heesewijk, Johannes P. M. van, E-mail: j.heesewijk@antoniusziekenhuis.nl
2012-12-15
Purpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24-85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registeredmore » fluoroscopy time, room time, interventional time, dose-area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results: Mean lesion diameter was 32.5 (range 3.0-93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1-7). Mean fluoroscopy time was 161 (range 104-551) s, room time was 34 (range 15-79) min, mean DAP value was 25.9 (range 3.9-80.5) Gy{center_dot}cm{sup -2}, and interventional time was 18 (range 5-65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86-96), 100% (95% CI 82-100), 100% (95% CI 96-100), 66.7% (95% CI 55-83), and 91.7% (95% CI 86-96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion: CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.« less
Initial investigation into lower-cost CT for resource limited regions of the world
NASA Astrophysics Data System (ADS)
Dobbins, James T., III; Wells, Jered R.; Segars, W. Paul; Li, Christina M.; Kigongo, Christopher J. N.
2010-04-01
This paper describes an initial investigation into means for producing lower-cost CT scanners for resource limited regions of the world. In regions such as sub-Saharan Africa, intermediate level medical facilities serving millions have no CT machines, and lack the imaging resources necessary to determine whether certain patients would benefit from being transferred to a hospital in a larger city for further diagnostic workup or treatment. Low-cost CT scanners would potentially be of immense help to the healthcare system in such regions. Such scanners would not produce state-of-theart image quality, but rather would be intended primarily for triaging purposes to determine the patients who would benefit from transfer to larger hospitals. The lower-cost scanner investigated here consists of a fixed digital radiography system and a rotating patient stage. This paper describes initial experiments to determine if such a configuration is feasible. Experiments were conducted using (1) x-ray image acquisition, a physical anthropomorphic chest phantom, and a flat-panel detector system, and (2) a computer-simulated XCAT chest phantom. Both the physical phantom and simulated phantom produced excellent image quality reconstructions when the phantom was perfectly aligned during acquisition, but artifacts were noted when the phantom was displaced to simulate patient motion. An algorithm was developed to correct for motion of the phantom and demonstrated success in correcting for 5-mm motion during 360-degree acquisition of images. These experiments demonstrated feasibility for this approach, but additional work is required to determine the exact limitations produced by patient motion.
Kao, S Y; Chou, J; Lo, J; Yang, J; Chou, A P; Joe, C J; Chang, R C
1999-04-01
Roentgenographic examination has long been a useful diagnostic tool for temporo-mandibular joint (TMJ) disease. The methods include TMJ tomography, panoramic radiography and computerized tomography (CT) scan with or without injection of contrast media. Recently, three-dimensional CT (3D-CT), reconstructed from the two-dimensional image of a CT scan to simulate the soft tissue or bony structure of the real target, was proposed. In this report, a case of TMJ ankylosis due to traumatic injury is presented. 3D-CT was employed as one of the presurgical roentgenographic diagnostic tools. The conventional radiographic examination including panoramic radiography and tomography showed lesions in both sides of the mandible. CT scanning further suggested that the right-sided lesion was more severe than that on the left. With 3D-CT image reconstruction the size and extent of the lesions were clearly observable. The decision was made to proceed with an initial surgical approach on the right side. With condylectomy and condylar replacement using an autogenous costochondral graft on the right side, the range of mouth opening improved significantly. In this case report, 3D-CT demonstrates its advantages as a tool for the correct and precise diagnosis of TMJ ankylosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Yakun; Li Xiang; Paul Segars, W.
Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representativemore » CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated male and female stylized phantoms. Results: For fully irradiated organs, average coefficients of variation (COV) ranged from 0.07 to 0.22 across the four male phantoms and from 0.06 to 0.18 across the four female phantoms; for partially irradiated organs, average COV ranged from 0.13 to 0.30 across the four male phantoms and from 0.15 to 0.30 across the four female phantoms. Doses to the testes, breasts, and esophagus showed large variations between phantoms. COV for gender-averaged effective dose and k factor ranged from 0.03 to 0.23 and from 0.06 to 0.30, respectively. COV for male risk index and q factor ranged from 0.06 to 0.30 and from 0.05 to 0.36, respectively; COV for female risk index and q factor ranged from 0.06 to 0.49 and from 0.07 to 0.54, respectively. Conclusions: Despite closely matched organ mass, total body weight, and height, large differences in organ dose exist due to variation in organ location, spatial distribution, and dose approximation method. Dose differences for fully irradiated radiosensitive organs were much smaller than those for partially irradiated organs. Weighted dosimetry quantities including effective dose, male risk indices, k factors, and male q factors agreed well across phantoms. The female risk indices and q factors varied considerably across phantoms.« less
Zhang, Yakun; Li, Xiang; Paul Segars, W.; Samei, Ehsan
2012-01-01
Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representative CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated male and female stylized phantoms. Results: For fully irradiated organs, average coefficients of variation (COV) ranged from 0.07 to 0.22 across the four male phantoms and from 0.06 to 0.18 across the four female phantoms; for partially irradiated organs, average COV ranged from 0.13 to 0.30 across the four male phantoms and from 0.15 to 0.30 across the four female phantoms. Doses to the testes, breasts, and esophagus showed large variations between phantoms. COV for gender-averaged effective dose and k factor ranged from 0.03 to 0.23 and from 0.06 to 0.30, respectively. COV for male risk index and q factor ranged from 0.06 to 0.30 and from 0.05 to 0.36, respectively; COV for female risk index and q factor ranged from 0.06 to 0.49 and from 0.07 to 0.54, respectively. Conclusions: Despite closely matched organ mass, total body weight, and height, large differences in organ dose exist due to variation in organ location, spatial distribution, and dose approximation method. Dose differences for fully irradiated radiosensitive organs were much smaller than those for partially irradiated organs. Weighted dosimetry quantities including effective dose, male risk indices, k factors, and male q factors agreed well across phantoms. The female risk indices and q factors varied considerably across phantoms. PMID:22755721
[A case of intragastric wall abscess formation during bevacizumab combined chemotherapy].
Mori, Ayano; Kogawa, Takahiro; Arihara, Youhei; Abe, Masakazu; Tamura, Fumito; Abe, Seiichirou; Kukitsu, Takehiro; Ihara, Hideyuki; Sumiyoshi, Tetsuya; Yoshizaki, Naoto; Kondou, Hitoshi; Tsuji, Yasushi
2013-05-01
A 38-year-old man was given a diagnosis of as sigmoid colon cancer and underwent sigmoid colectomy. Post-operative pathological staging was stage IIIb. He then underwent adjuvant chemotherapy. One year and 4 months after the surgery, CT scans revealed multiple liver and lung metastases. He was given mFOLFOX6+bevacizumab, which was changed later to FOLFIRI+bevacizumab. After these chemotherapies, he was admitted to the hospital due to sudden abdominal pain and high grade fever. Obstructive jaundice was initially diagnosed, but detailed study of initial CT revealed intragastric wall abscess. After the drainage of the abscess, his conditions improved. We speculated that the abscess formation was caused by mucosal damage due to bevacizumab.
Yang, Xu-Yang; Wei, Ming-Tian; Jin, Cheng-Wu; Wang, Meng; Wang, Zi-Qiang
2016-03-01
To identify and describe the major features of unenhanced computed tomography (CT) images of blunt hollow viscera and/or mesenteric injury (BHVI/MI) and to determine the value of unenhanced CT in the diagnosis of BHVI/MI. This retrospective study included 151 patients who underwent unenhanced CT before laparotomy for blunt abdominal trauma between January 2011 and December 2013. According to surgical observations, patients were classified as having BHVI/MI (n = 73) or not (n = 78). Sensitivity, specificity, P values, and likelihood ratios were calculated by comparing CT findings between the 2 groups. Six significant CT findings (P < 0.05) for BHVI/MI were identified and their sensitivity and specificity values determined, as follows: bowel wall thickening (39.7%, 96.2%), mesentery thickening (46.6%, 88.5%), mesenteric fat infiltration (12.3%, 98.7%), peritoneal fat infiltration (31.5%, 87.1%), parietal peritoneum thickening (30.1%, 85.9%), and intra- or retro-peritoneal air (34.2%, 96.2%). Unenhanced CT scan was useful as an initial assessment tool for BHVI/MI after blunt abdominal trauma. Six key features on CT were correlated with BHVI/MI.
Jung, Ji-Hoon; Lee, Sang-Woo; Son, Seung Hyun; Kim, Choon-Young; Lee, Chang-Hee; Jeong, Ju Hye; Jeong, Shin Young; Ahn, Byeong-Cheol; Lee, Jaetae
2017-03-01
The purpose of this retrospective study was to assess the diagnostic value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT and the prognostic value of metabolic PET parameters in patients with adenoid cystic carcinoma of the head and neck (ACCHN). Forty patients with newly diagnosed ACCHN were enrolled in this study. We investigated the diagnostic value of 18 F-FDG PET/CT for detecting and staging compared to conventional CT. Kaplan-Meier survival analysis for progression-free survival (PFS) was performed with clinicopathological factors and metabolic PET parameters. The 18 F-FDG PET/CT showed comparable sensitivity (92.3%) to conventional CT for lesion detection, and changed staging and management plan in 6 patients (15.0%). Lower PFS rates were associated with advanced T classification, advanced TNM classification, high maximum standardized uptake value (SUVmax; >5.1), and high total lesion glycolysis (>40.1) of the primary tumor. The 18 F-FDG PET/CT can provide additional information for initial staging, and metabolic PET parameters may serve as prognostic factors of ACCHN. © 2016 Wiley Periodicals, Inc. Head Neck 39: 447-455, 2017. © 2016 Wiley Periodicals, Inc.
Computed tomography and clinical outcome in patients with severe traumatic brain injury.
Stenberg, Maud; Koskinen, Lars-Owe D; Jonasson, Per; Levi, Richard; Stålnacke, Britt-Marie
2017-01-01
To study: (i) acute computed tomography (CT) characteristics and clinical outcome; (ii) clinical course and (iii) Corticosteroid Randomisation after Significant Head Injury acute calculator protocol (CRASH) model and clinical outcome in patients with severe traumatic brain injury (sTBI). Initial CT (CT i ) and CT 24 hours post-trauma (CT 24 ) were evaluated according to Marshall and Rotterdam classifications. Rancho Los Amigos Cognitive Scale-Revised (RLAS-R) and Glasgow Outcome Scale Extended (GOSE) were assessed at three months and one year post-trauma. The prognostic value of the CRASH model was evaluated. Thirty-seven patients were included. Marshall CT i and CT 24 were significantly correlated with RLAS-R at three months. Rotterdam CT 24 was significantly correlated with GOSE at three months. RLAS-R and the GOSE improved significantly from three months to one year. CRASH predicted unfavourable outcome at six months for 81% of patients with bad outcome and for 85% of patients with favourable outcome according to GOSE at one year. Neither CT nor CRASH yielded clinically useful predictions of outcome at one year post-injury. The study showed encouragingly many instances of significant recovery in this population of sTBI. The combination of lack of reliable prognostic indicators and favourable outcomes supports the case for intensive acute management and rehabilitation as the default protocol in the cases of sTBI.
NASA Astrophysics Data System (ADS)
Edo, Takahiro; Asai, T.; Tanaka, F.; Yamada, S.; Hosozawa, A.; Gota, H.; Roche, T.; Allfrey, I.; Matsumoto, T.
2017-10-01
A magnetized coaxial plasma gun (MCPG) is a device used to generate a compact toroid (CT), which has a spheromak-like configuration. A typical MCPG consists of a set of axisymmetric cylindrical electrodes, bias coil, and gas-puff valves. In order to expand the CT operating range, the distributions of the bias magnetic field and neutral gas have been investigated. We have developed a new means of generating stuffing flux. By inserting an iron core into the bias coil, the magnetic field increases dramatically; even a small current of a few Amps produces a sufficient bias field. According to a simulation result, it was also suggested that the radial distribution of the bias field is easily controlled. The ejected CT and the target FRC are cooled by excess neutral gas that typical MCPGs require to initiate a breakdown; therefore, we have adopted a miniature gun as a new pre-ionization (PI) system. By introducing this PI system, the breakdown occurs at lower neutral gas density so that the amount of excess neutral gas can be reduced.
Tetrameric Ctp1 coordinates DNA binding and DNA bridging in DNA double-strand-break repair
Andres, Sara N.; Appel, C. Denise; Westmoreland, James W.; ...
2015-01-12
Ctp1 (also known as CtIP or Sae2) collaborates with Mre11-Rad50-Nbs1 to initiate repair of DNA double-strand breaks (DSBs), but its functions remain enigmatic. In this paper, we report that tetrameric Schizosaccharomyces pombe Ctp1 contains multivalent DNA-binding and DNA-bridging activities. Through structural and biophysical analyses of the Ctp1 tetramer, we define the salient features of Ctp1 architecture: an N-terminal interlocking tetrameric helical dimer-of-dimers (THDD) domain and a central intrinsically disordered region (IDR) linked to C-terminal 'RHR' DNA-interaction motifs. The THDD, IDR and RHR are required for Ctp1 DNA-bridging activity in vitro, and both the THDD and RHR are required for efficientmore » DSB repair in S. pombe. Finally, our results establish non-nucleolytic roles of Ctp1 in binding and coordination of DSB-repair intermediates and suggest that ablation of human CtIP DNA binding by truncating mutations underlie the CtIP-linked Seckel and Jawad syndromes.« less
Iatrogenic radiation exposure to patients with early onset spine and chest wall deformities.
Khorsand, Derek; Song, Kit M; Swanson, Jonathan; Alessio, Adam; Redding, Gregory; Waldhausen, John
2013-08-01
Retrospective cohort series. Characterize average iatrogenic radiation dose to a cohort of children with thoracic insufficiency syndrome (TIS) during assessment and treatment at a single center with vertically expandable prosthetic titanium rib. Children with TIS undergo extensive evaluations to characterize their deformity. No standardized radiographical evaluation exists, but all reports use extensive imaging. The source and level of radiation these patients receive is not currently known. We evaluated a retrospective consecutive cohort of 62 children who had surgical treatment of TIS at our center from 2001-2011. Typical care included obtaining serial radiographs, spine and chest computed tomographic (CT) scans, ventilation/perfusion scans, and magnetic resonance images. Epochs of treatment were divided into time of initial evaluation to the end of initial vertically expandable prosthetic titanium rib implantation with each subsequent epoch delineated by the next surgical intervention. The effective dose for each examination was estimated within millisieverts (mSv). Plain radiographs were calculated from references. Effective dose was directly estimated for CT scans since 2007 and an average of effective dose from 2007-2011 was used for scans before 2007. Effective dose from fluoroscopy was directly estimated. All doses were reported in mSv. A cohort of 62 children had a total of 447 procedures. There were a total of 290 CT scans, 4293 radiographs, 147 magnetic resonance images, and 134 ventilation/perfusion scans. The average accumulated effective dose was 59.6 mSv for children who had completed all treatment, 13.0 mSv up to initial surgery, and 3.2 mSv for each subsequent epoch of treatment. CT scans accounted for 74% of total radiation dose. Children managed for TIS using a consistent protocol received iatrogenic radiation doses that were on average 4 times the estimated average US background radiation exposure of 3 mSv/yr. CT scans comprised 74% of the total dose. 3.
Hnatyszyn, Andrzej; Wielgus, Karolina; Kaczmarek-Rys, Marta; Skrzypczak-Zielinska, Marzena; Szalata, Marlena; Mikolajczyk-Stecyna, Joanna; Stanczyk, Jerzy; Dziuba, Ireneusz; Mikstacki, Adam; Slomski, Ryszard
2013-12-01
Epidemiological investigations indicated association of the Helicobacter pylori infections with the occurrence of inflammatory conditions of the gastric mucosa and development of chronic gastritis and intestinal type of gastric cancer. IL1A and IL1B genes have been proposed as key factors in determining risk of gastritis and malignant transformation. The aim of this paper was to evaluate association of interleukin-1 gene polymorphisms with chronic gastritis, atrophy, intestinal metaplasia, dysplasia and intestinal type of gastric cancer in H. pylori-infected patients. Patients subjected to analysis represent group of 144 consecutive cases that suffered from dyspepsia with coexisting infection of H. pylori and chronic gastritis, chronic atrophic gastritis, intestinal metaplasia, dysplasia or gastric cancer. Molecular studies involved analysis of -889C>T polymorphism of IL1A gene and +3954C>T polymorphism of IL1B gene. Statistical analysis of association of polymorphism -889C>T of gene IL1A with changes in gastric mucosa showed lack of significance, whereas +3954C>T polymorphism of IL1B gene showed significant association. Frequency of allele T of +3954C>T polymorphism of IL1B gene was higher in group of patients with chronic gastritis, atrophy, intestinal metaplasia, dysplasia or intestinal type of gastric cancer (32.1 %) as compared with population group (23 %), χ(2) = 4.61 and p = 0.03. This corresponds to odds ratio: 1.58, 95 % CI: 1.04-2.4. Our results indicate that +3954C>T polymorphism of IL1B gene increase susceptibility to inflammatory response of gastric mucosa H. pylori-infected patients and plays a significant role in the development of chronic gastritis, atrophy, intestinal metaplasia, dysplasia and the initiation of carcinogenesis.
Organic soil production from urban soil, spent mushroom substrate, and other additives
NASA Astrophysics Data System (ADS)
Pham, Nhung Thi Ha
2017-09-01
In recent years, spent mushroom substrate (SMS) is becoming the huge problem in environmental pollution issues from mushroom production. However, SMS is also a nutrient-rich ogranic material with available nutrients and high porosity. Therefore, the value of products made from SMS should be exploited to take full advantage of agricultural by-product, support organic agriculture development without environmental pollution. The research has built 5 experimental formulas (4 mixed formulas and 1 control formulas with only urban soil). The analysis results of soil samples from mixed formulas and the control formula witness a significant increase in moisture and OM of mixed formulas (moisture from 36-42%, OM from 5.5-6.9%) after 20 treatment days, and N-P-K contents are also improved remarkably. 60 days later, soil nutrients in mixed formulas continue to rise, with highest OM (8.679%) at CT1; N (0.154%) at CT4; K2O (0,698%) and P2O5 (0,172%) at CT3, in addition, heavy metal contents in all formulas are under standard limit. Synthetic assessment of all norms indicates that the best organic soil product comes from CT3. The pak choi planting experiments are performed show that the growth of plants cultivated on organic soil products made from mixed formulas are much better than plants are grown on initially soil, and they also have no pestilent insect. Specially, pak choi planted on organic soil from CT3 have sharp developing with excellent tolerance ability, quantity and area of leaves are high. Thus, CT3 is the most suitable formula to increase soil nutrients, to solve spent mushroom subtrate streament problems after harvest, and for sustainable agricultural development.
Spector, Alan C; Blonde, Ginger; Garcea, Mircea; Jiang, Enshe
2010-01-15
Forty years have passed since it was demonstrated that a cross-regenerated gustatory nerve in the rat tongue adopts the stimulus-response properties of the taste receptor field it cross-reinnervates. Nevertheless, the functional consequences of channeling peripheral taste signals through inappropriate central circuits remain relatively unexplored. Here we tested whether histologically confirmed cross-regeneration of the chorda tympani nerve (CT) into the posterior tongue in the absence of the glossopharyngeal nerve (GL) (CT-PostTongue) or cross-regeneration of the GL into the anterior tongue in the absence of the CT (GL-AntTongue) would maintain presurgically trained performance in an operant NaCl vs. KCl taste discrimination task in rats. Before surgery all groups were averaging over 90% accuracy. Oral amiloride treatment dropped performance to virtually chance levels. During the first week after surgery, sham-operated rats, GL-transected rats, and rats with regenerated CTs displayed highly competent discrimination performance. In contrast, CT-transected rats were severely impaired (59% accuracy). Both the CT-PostTongue and the GL-AntTongue groups were impaired to a similar degree as CT-transected rats. These initially impaired groups improved their performance over the weeks of postsurgical testing, suggesting that the rats were capable of relearning the task with discriminable signals in the remaining taste nerves. This relearned performance was dependent on input from amiloride-sensitive receptors likely in the palate. Overall, these results suggest that normal competence in a salt discrimination task is dependent on the taste receptor field origin of the input as well as the specific nerve transmitting the signals to its associated circuits in the brain. Copyright 2009 Elsevier B.V. All rights reserved.
Can SNOMED CT be squeezed without losing its shape?
López-García, Pablo; Schulz, Stefan
2016-09-21
In biomedical applications where the size and complexity of SNOMED CT become problematic, using a smaller subset that can act as a reasonable substitute is usually preferred. In a special class of use cases-like ontology-based quality assurance, or when performing scaling experiments for real-time performance-it is essential that modules show a similar shape than SNOMED CT in terms of concept distribution per sub-hierarchy. Exactly how to extract such balanced modules remains unclear, as most previous work on ontology modularization has focused on other problems. In this study, we investigate to what extent extracting balanced modules that preserve the original shape of SNOMED CT is possible, by presenting and evaluating an iterative algorithm. We used a graph-traversal modularization approach based on an input signature. To conform to our definition of a balanced module, we implemented an iterative algorithm that carefully bootstraped and dynamically adjusted the signature at each step. We measured the error for each sub-hierarchy and defined convergence as a residual sum of squares <1. Using 2000 concepts as an initial signature, our algorithm converged after seven iterations and extracted a module 4.7 % the size of SNOMED CT. Seven sub-hierarhies were either over or under-represented within a range of 1-8 %. Our study shows that balanced modules from large terminologies can be extracted using ontology graph-traversal modularization techniques under certain conditions: that the process is repeated a number of times, the input signature is dynamically adjusted in each iteration, and a moderate under/over-representation of some hierarchies is tolerated. In the case of SNOMED CT, our results conclusively show that it can be squeezed to less than 5 % of its size without any sub-hierarchy losing its shape more than 8 %, which is likely sufficient in most use cases.
Siri, Sangeeta K; Latte, Mrityunjaya V
2017-11-01
Many different diseases can occur in the liver, including infections such as hepatitis, cirrhosis, cancer and over effect of medication or toxins. The foremost stage for computer-aided diagnosis of liver is the identification of liver region. Liver segmentation algorithms extract liver image from scan images which helps in virtual surgery simulation, speedup the diagnosis, accurate investigation and surgery planning. The existing liver segmentation algorithms try to extort exact liver image from abdominal Computed Tomography (CT) scan images. It is an open problem because of ambiguous boundaries, large variation in intensity distribution, variability of liver geometry from patient to patient and presence of noise. A novel approach is proposed to meet challenges in extracting the exact liver image from abdominal CT scan images. The proposed approach consists of three phases: (1) Pre-processing (2) CT scan image transformation to Neutrosophic Set (NS) and (3) Post-processing. In pre-processing, the noise is removed by median filter. The "new structure" is designed to transform a CT scan image into neutrosophic domain which is expressed using three membership subset: True subset (T), False subset (F) and Indeterminacy subset (I). This transform approximately extracts the liver image structure. In post processing phase, morphological operation is performed on indeterminacy subset (I) and apply Chan-Vese (C-V) model with detection of initial contour within liver without user intervention. This resulted in liver boundary identification with high accuracy. Experiments show that, the proposed method is effective, robust and comparable with existing algorithm for liver segmentation of CT scan images. Copyright © 2017 Elsevier B.V. All rights reserved.
Low-voltage chest CT: another way to reduce the radiation dose in asbestos-exposed patients.
Macía-Suárez, D; Sánchez-Rodríguez, E; Lopez-Calviño, B; Diego, C; Pombar, M
2017-09-01
To assess whether low voltage chest computed tomography (CT) can be used to successfully diagnose disease in patients with asbestos exposure. Fifty-six former employees of the shipbuilding industry, who were candidates to receive a standard-dose chest CT due to their occupational exposure to asbestos, underwent a routine CT. Immediately after this initial CT, they underwent a second acquisition using low-dose chest CT parameters, based on a low potential (80 kV) and limited tube current. The findings of the two CT protocols were compared based on typical diseases associated with asbestos exposure. The kappa coefficient for each parameter and for an overall rating (grouping them based on mediastinal, pleural, and pulmonary findings) were calculated in order to test for correlations between the two protocols. A good correlation between routine and low-dose CT was demonstrated for most parameters with a mean radiation dose reduction of up to 83% of the effective dose based on the dose-length product between protocols. Low-dose chest CT, based on a limited tube potential, is useful for patients with an asbestos exposure background. Low-dose chest CT can be successfully used to minimise the radiation dose received by patients, as this protocol produced an estimated mean effective dose similar to that of an abdominal or pelvis plain film. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hiniker, Susan M.; Pollom, Erqi L.; Khodadoust, Michael S.
2015-05-01
Background: The role of surveillance studies in limited-stage diffuse large B-cell lymphoma (DLBCL) in the rituximab era has not been well defined. We sought to evaluate the use of imaging (computed tomography [CT] and positron emission tomography [PET]-CT) scans and lactate dehydrogenase (LDH) in surveillance of patients with stage I to II DLBCL. Methods: A retrospective analysis was performed of patients who received definitive treatment between 2000 and 2013. Results: One hundred sixty-two consecutive patients with stage I to II DLBCL were treated with chemotherapy +/− rituximab, radiation, or combined modality therapy. The 5-year rates of overall survival (OS) and freedommore » from progression (FFP) were 81.2% and 80.8%, respectively. Of the 162 patients, 124 (77%) were followed up with at least 1 surveillance PET scan beyond end-of-treatment scans; of those, 94 of 124 (76%) achieved a complete metabolic response on PET scan after completion of chemotherapy, and this was associated with superior FFP (P=.01, HR=0.3) and OS (P=.01, HR 0.3). Eighteen patients experienced relapse after initial response to therapy. Nine relapses were initially suspected by surveillance imaging studies (8 PET, 1 CT), and 9 were suspected clinically (5 by patient-reported symptoms and 4 by symptoms and physical examination). No relapses were detected by surveillance LDH. The median duration from initiation of treatment to relapse was 14.3 months among patients with relapses suspected by imaging, and 59.8 months among patients with relapses suspected clinically (P=.077). There was no significant difference in OS from date of first therapy or OS after relapse between patients whose relapse was suspected by imaging versus clinically. Thirteen of 18 patients underwent successful salvage therapy after relapse. Conclusions: A complete response on PET scan immediately after initial chemotherapy is associated with superior FFP and OS in stage I to II DLBCL. The use of PET scans as posttreatment surveillance is not associated with a survival advantage. LDH is not a sensitive marker for relapse. Our results argue for limiting the use of posttreatment surveillance in patients with limited-stage DLBCL.« less
Shamim, Shelley; Thakur, Sumitra Basu; Sengupta, Amitava; Bhattacharyya, Sujit Kumar; Sit, Niranjan
2010-01-01
The most common cause of massive hemorrhagic effusion is malignancy. Herein we present a case of dissecting aneurysm of descending thoracic aorta presenting initially with shortness of breath due to left sided massive pleural effusion. Effusion was hemorrhagic in nature with high hematocrit value. CT scan of thorax with CT angiogram was done and that revealed the diagnosis. PMID:21139725
Metallurgical Design and Development of NASA Crawler/Transporter Tread Belt Shoe Castings
NASA Technical Reports Server (NTRS)
Parker, Donald S.
2006-01-01
The NASA Crawler/Transporters (CT-1 and CT-2) used to transport the Space Shuffles are one of the largest tracked vehicles in existence today. Two of these machines have been used to move space flight vehicles at Kennedy Space Center since the Apollo missions of the 1960's and relatively few modifications have been made to keep them operational. In September of 2003 during normal Crawler/Transporter operations cracks were observed along the roller pad surfaces of several tread belt shoes. Further examination showed 20 cracked shoes on CT-1 and 40 cracked shoes on CT-2 and a formal failure analysis investigation was undertaken while the cracked shoes were replaced. Six shoes were cross-sectioned with the fracture surfaces exposed and it was determined that the cracks were due to fatigue that initiated on the internal casting web channels at pre-existing casting defects and propagated through thickness both transgranularly and intergranularly between internal shrinkage cavities, porosity, and along austenitic and ferritic grain boundaries. The original shoes were cast during the 1960's using a modified 861330 steel with slightly higher levels of chromium, nickel and molybdenum followed by heat treatment to achieve a minimum tensile strength of 11 Oksi. Subsequent metallurgical analysis of the tread belt shoes after multiple failures showed excessive internal defects, alloy segregation, a nonuniform ferritic/ bainitic/martensitic microstructure, and low average tensile properties indicative of poor casting and poor heat-treatment. As a result, NASA funded an initiative to replace all of the tread belt shoes on both crawler/transporters along with a redesign of the alloy, manufacturing, and heat-treatment to create a homogeneous cast structure with uniform mechanical and metallurgical properties. ME Global, a wholly owned subsidiary of ME Elecmetal based in Minneapolis, MN was selected as manufacturing and design partner to develop the new shoes and this paper describes the research, development, and manufacturing that resulted in the successful delivery of 1044 new Crawler/Transporter tread belt shoes all meeting rigid metallurgical and mechanical design criteria derived from finite element modeling of the stress loads required for safe space shuttle transport.
Ayaz, Sevin; Ayaz, Ümit Yaşar
2016-01-01
We aimed to present unusual cranial FDG PET/CT findings of a 56-year-old female with multiple myeloma (MM). Plain CT images revealed a lytic lesion in the right parietal bone, filled with an oval-shaped, large, extra-axial, extradural, intracranial mass which measured 75×75×40 mm and had smooth borders. The right parietal lobe was compressed by the mass. The maximum standardized uptake value (SUV max ) of the mass lesion was 8.94 on FDG PET/CT images. Multiple lytic lesions with an increased uptake were also detected in other calvarial bones, in several vertebras and in the proximal left femur. After seven months, a control FDG PET/CT following radiotherapy and chemotherapy revealed almost complete regression of the right parietal extra-axial mass lesion. The number, size and metabolism of lytic lesions in other bones also decreased. FDG PET/CT was useful for an initial evaluation of MM lesions and was effective in monitoring the response of these lesions to therapy.
[Virtual otoscopy--technique, indications and initial experiences with multislice spiral CT].
Klingebiel, R; Bauknecht, H C; Lehmann, R; Rogalla, P; Werbs, M; Behrbohm, H; Kaschke, O
2000-11-01
We report the standardized postprocessing of high-resolution CT data acquired by incremental CT and multi-slice CT in patients with suspected middle ear disorders to generate three-dimensional endoluminal views known as virtual otoscopy. Subsequent to the definition of a postprocessing protocol, standardized endoluminal views of the middle ear were generated according to their otological relevance. The HRCT data sets of 26 ENT patients were transferred to a workstation and postprocessed to 52 virtual otoscopies. Generation of predefined endoluminal views from the HRCT data sets was possible in all patients. Virtual endoscopic views added meaningful information to the primary cross-sectional data in patients suffering from ossicular pathology, having contraindications for invasive tympanic endoscopy or being assessed for surgery of the tympanic cavity. Multi slice CT improved the visualization of subtle anatomic details such as the stapes suprastructure and reduced the scanning time. Virtual endoscopy allows for the non invasive endoluminal visualization of various tympanic lesions. Use of the multi-slice CT technique reduces the scanning time and improves image quality in terms of detail resolution.
TH-AB-202-03: A Novel Tool for Computing Deliverable Doses in Dynamic MLC Tracking Treatments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fast, M; Kamerling, C; Menten, M
2016-06-15
Purpose: In tracked dynamic multi-leaf collimator (MLC) treatments, segments are continuously adapted to the target centroid motion in beams-eye-view. On-the-fly segment adaptation, however, potentially induces dosimetric errors due to the finite MLC leaf width and non-rigid target motion. In this study, we outline a novel tool for computing the 4d dose of lung SBRT plans delivered with MLC tracking. Methods: The following automated workflow was developed: A) centroid tracking, where the initial segments are morphed to each 4dCT phase based on the beams-eye-view GTV shift (followed by a dose calculation on each phase); B) re-optimized tracking, in which all morphedmore » initial plans from (A) are further optimised (“warm-started”) in each 4dCT phase using the initial optimisation parameters but phase-specific volume definitions. Finally, both dose sets are accumulated to the reference phase using deformable image registration. Initial plans were generated according to the RTOG-1021 guideline (54Gy, 3-Fx, equidistant 9-beam IMRT) on the peak-exhale (reference) phase of a phase-binned 4dCT. Treatment planning and delivery simulations were performed in RayStation (research v4.6) using our in-house segment-morphing algorithm, which directly links to RayStation through a native C++ interface. Results: Computing the tracking plans and 4d dose distributions via the in-house interface takes 5 and 8 minutes respectively for centroid and re-optimized tracking. For a sample lung SBRT patient with 14mm peak-to-peak motion in sup-inf direction, mainly perpendicular leaf motion (0-collimator) resulted in small dose changes for PTV-D95 (−13cGy) and GTV-D98 (+18cGy) for the centroid tracking case compared to the initial plan. Modest reductions of OAR doses (e.g. spinal cord D2: −11cGy) were achieved in the idealized tracking case. Conclusion: This study presents an automated “1-click” workflow for computing deliverable MLC tracking doses in RayStation. Adding a non-deliverable re-optimized tracking scenario is expected to help quantify plan robustness for more challenging patients with anatomy deformations. We acknowledge support of the MLC tracking research from Elekta AB. MFF is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.« less
Akpinar, Erhan; Türkbey, Bariş; Cil, Barbaros Erhan; Canyiğit, Murat; Dündar, Ziya; Balkanci, Ferhun
2007-06-01
Acute lower gastrointestinal system (GIS) bleeding is a life-threatening condition. Immediate determination of the origin of the bleeding is crucial, since hemostatic management must be initiated as rapidly as possible. Colonoscopy, radionuclide studies, and conventional angiography are considered the most important methods for assessing the origin of the bleeding. There are few published reports about the feasibility of computed tomography (CT) in acute GIS bleeding. We present multidetector CT (MDCT) findings in a case of Hodgkin disease status one month post-chemotherapy (CHOP protocol; cyclophosphamide, doxorubicin, vincristine, prednisone) that presented with acute lower GIS bleeding.
Joshi, Prathamesh; Lele, Vikram
2013-04-01
Opsoclonus-myoclonus ataxia (OMA) syndrome is the most common paraneoplastic neurological syndrome of childhood, associated with occult neuroblastoma in 20%-50% of all cases. OMA is the initial presentation of neuroblastoma in 1%-3% of children. Conventional radiological imaging approaches include chest radiography and abdominal computed tomography (CT). Nuclear medicine techniques, in form of (123)I/(131)I-metaiodobenzylguanidine (MIBG) scintigraphy have been incorporated in various diagnostic algorithms for evaluation of OMA. We describe use of somatostatin receptor PET/CT with (68)Gallium- DOTA-DPhe(1), Tyr(3)-octreotate (DOTATATE) in diagnosis of neuroblastoma in two cases of OMA.
Initial experience in treating lung cancer with helical tomotherapy
Yartsev, S; Dar, AR; Woodford, C; Wong, E; Bauman, G; Van Dyk, J
2007-01-01
Helical tomotherapy is a new form of image-guided radiation therapy that combines features of a linear accelerator and a helical computed tomography (CT) scanner. Megavoltage CT (MVCT) data allow the verification and correction of patient setup on the couch by comparison and image registration with the kilovoltage CT multi-slice images used for treatment planning. An 84-year-old male patient with Stage III bulky non-small cell lung cancer was treated on a Hi-ART II tomotherapy unit. Daily MVCT imaging was useful for setup corrections and signaled the need to adapt the delivery plan when the patient’s anatomy changed significantly. PMID:21614260
Zhang, You; Ma, Jianhua; Iyengar, Puneeth; Zhong, Yuncheng; Wang, Jing
2017-01-01
Purpose Sequential same-patient CT images may involve deformation-induced and non-deformation-induced voxel intensity changes. An adaptive deformation recovery and intensity correction (ADRIC) technique was developed to improve the CT reconstruction accuracy, and to separate deformation from non-deformation-induced voxel intensity changes between sequential CT images. Materials and Methods ADRIC views the new CT volume as a deformation of a prior high-quality CT volume, but with additional non-deformation-induced voxel intensity changes. ADRIC first applies the 2D-3D deformation technique to recover the deformation field between the prior CT volume and the new, to-be-reconstructed CT volume. Using the deformation-recovered new CT volume, ADRIC further corrects the non-deformation-induced voxel intensity changes with an updated algebraic reconstruction technique (‘ART-dTV’). The resulting intensity-corrected new CT volume is subsequently fed back into the 2D-3D deformation process to further correct the residual deformation errors, which forms an iterative loop. By ADRIC, the deformation field and the non-deformation voxel intensity corrections are optimized separately and alternately to reconstruct the final CT. CT myocardial perfusion imaging scenarios were employed to evaluate the efficacy of ADRIC, using both simulated data of the extended-cardiac-torso (XCAT) digital phantom and experimentally acquired porcine data. The reconstruction accuracy of the ADRIC technique was compared to the technique using ART-dTV alone, and to the technique using 2D-3D deformation alone. The relative error metric and the universal quality index metric are calculated between the images for quantitative analysis. The relative error is defined as the square root of the sum of squared voxel intensity differences between the reconstructed volume and the ‘ground-truth’ volume, normalized by the square root of the sum of squared ‘ground-truth’ voxel intensities. In addition to the XCAT and porcine studies, a physical lung phantom measurement study was also conducted. Water-filled balloons with various shapes/volumes and concentrations of iodinated contrasts were put inside the phantom to simulate both deformations and non-deformation-induced intensity changes for ADRIC reconstruction. The ADRIC-solved deformations and intensity changes from limited-view projections were compared to those of the ‘gold-standard’ volumes reconstructed from fully-sampled projections. Results For the XCAT simulation study, the relative errors of the reconstructed CT volume by the 2D-3D deformation technique, the ART-dTV technique and the ADRIC technique were 14.64%, 19.21% and 11.90% respectively, by using 20 projections for reconstruction. Using 60 projections for reconstruction reduced the relative errors to 12.33%, 11.04% and 7.92% for the three techniques, respectively. For the porcine study, the corresponding results were 13.61%, 8.78%, 6.80% by using 20 projections; and 12.14%, 6.91% and 5.29% by using 60 projections. The ADRIC technique also demonstrated robustness to varying projection exposure levels. For the physical phantom study, the average DICE coefficient between the initial prior balloon volume and the new ‘gold-standard’ balloon volumes was 0.460. ADRIC reconstruction by 21 projections increased the average DICE coefficient to 0.954. Conclusion The ADRIC technique outperformed both the 2D-3D deformation technique and the ART-dTV technique in reconstruction accuracy. The alternately solved deformation field and non-deformation voxel intensity corrections can benefit multiple clinical applications, including tumor tracking, radiotherapy dose accumulation and treatment outcome analysis. PMID:28380247
A Multi-Source Inverse-Geometry CT system: Initial results with an 8 spot x-ray source array
Baek, Jongduk; De Man, Bruno; Uribe, Jorge; Longtin, Randy; Harrison, Daniel; Reynolds, Joseph; Neculaes, Bogdan; Frutschy, Kristopher; Inzinna, Louis; Caiafa, Antonio; Senzig, Robert; Pelc, Norbert J.
2014-01-01
We present initial experimental results of a rotating-gantry multi-source inverse-geometry CT (MS-IGCT) system. The MS-IGCT system was built with a single module of 2×4 x-ray sources and a 2D detector array. It produced a 75 mm in-plane field-of-view (FOV) with 160 mm axial coverage in a single gantry rotation. To evaluate system performance, a 2.5 inch diameter uniform PMMA cylinder phantom, a 200 μm diameter tungsten wire, and a euthanized rat were scanned. Each scan acquired 125 views per source and the gantry rotation time was 1 second per revolution. Geometric calibration was performed using a bead phantom. The scanning parameters were 80 kVp, 125 mA, and 5.4 us pulse per source location per view. A data normalization technique was applied to the acquired projection data, and beam hardening and spectral nonlinearities of each detector channel were corrected. For image reconstruction, the projection data of each source row were rebinned into a full cone beam data set, and the FDK algorithm was used. The reconstructed volumes from upper and lower source rows shared an overlap volume which was combined in image space. The images of the uniform PMMA cylinder phantom showed good uniformity and no apparent artefacts. The measured in-plane MTF showed 13 lp/cm at 10% cutoff, in good agreement with expectations. The rat data were also reconstructed reliably. The initial experimental results from this rotating-gantry MS-IGCT system demonstrated its ability to image a complex anatomical object without any significant image artefacts and to achieve high image resolution and large axial coverage in a single gantry rotation. PMID:24556567
Laser, Adriana; Kufera, Joseph A; Bruns, Brandon R; Sliker, Clint W; Tesoriero, Ronald B; Scalea, Thomas M; Stein, Deborah M
2015-09-01
Our whole-body computed tomography protocol (WBCT), used to image patients with polytrauma, consists of a noncontrast head computed tomography (CT) followed by a multidetector computed tomography (40- or 64- slice) that includes an intravenous, contrast-enhanced scan from the face through the pelvis. WBCT is used to screen for blunt cerebrovascular injury (BCVI) during initial CT imaging of the patient with polytrauma and allows for early initiation of therapy with the goal of avoiding stroke. WBCT has not been directly compared with CT angiography (CTA) of the neck as a screening tool for BCVI. We hypothesize that WBCT is a valid modality to diagnose BCVI compared with neck CTA, thus screening patients with polytrauma for BCVI and limiting the need for subsequent CTA. A retrospective review of the trauma registry was conducted for all patients diagnosed with BCVI from June 2009 to June 2013 at our institution. All injuries, identified and graded on initial WBCT, were compared with neck CTA imaging performed within the first 72 hours. Sensitivity was calculated for WBCT by the use of CTA as the reference standard. Proportions of agreement also were calculated between the grades of injury for both imaging modalities. A total of 319 injured vessels were identified in 227 patients. On initial WBCT 80 (25%) of the injuries were grade I, 75 (24%) grade II, 45 (14%) grade III, 41 (13%) grade IV, and 58 (18%) were classified as indeterminate: 27 vertebral and 31 carotid lesions. Twenty (6%) of the 319 injuries were not detected on WBCT but identified on subsequent CTA (9 grade I, 7 grade II, 4 grade III); 6 vertebral and 14 carotid. For each vessel type and for all vessels combined, WBCT demonstrated sensitivity rates of over 90% to detect BCVI among the population of patients with at least one vessel injured. There was concordant grading of injuries between WBCT and initial diagnostic CTA in 154 (48% of all injuries). Lower grade injures were more discordant than higher grades (55% vs 13%, respectively; P < .001). Grading was upgraded 8% of the time and downgraded 25%. WBCT holds promise as a rapid screening test for BCVI in the patient with polytrauma to identify injuries in the early stage of the trauma evaluation, thus allowing more rapid initiation of treatment. In addition, in those patients with high risk for BCVI but whose WBCT results are negative for BCVI, neck CTA should be considered to more confidently exclude low-grade injuries. Copyright © 2015 Elsevier Inc. All rights reserved.
Hideghéty, Katalin; Cserháti, Adrienne; Besenyi, Zsuzsanna; Zag, Levente; Gaál, Szilvia; Együd, Zsófia; Mózes, Petra; Szántó, Erika; Csenki, Melinda; Rusz, Orsolya; Varga, Zoltán; Dobi, Ágnes; Maráz, Anikó; Pávics, László; Lengyel, Zsolt
2015-06-01
The purpose of our work is evaluation of the impact of 18FDG-PET/CT on the complex management of locoregionally advanced (T3-4N1-3) head and neck squamous cell cancer (LAHNSC), and on the target definition for 3D conformal (3DCRT) and intensity-modulated radiotherapy (IMRT). 18FDG-PET/CT were performed on 185 patients with LAHNSC prior to radiotherapy/chemoradiation in the treatment position between 2006 and 2011. Prior to it 91 patients received induction chemotherapy (in 20 cases of these, baseline PET/CT was also available). The independently delineated CT-based gross tumor volume (GTVct) and PET/CT based ones (GTVpet) were compared. Impact of PET/CT on the treatment strategy, on tumor response evaluation to ICT, on GTV definition furthermore on overall and disease-specific survival (OS, DSS) was analysed. PET/CT revealed 10 head and neck, 2 lung cancers for 15 patients with carcinoma of unknown primary (CUP) while 3 remained unknown. Second tumors were detected in 8 (4.4%), distant metastasis in 15 (8.2%) cases. The difference between GTVct and GTVpet was significant (p=0.001). In 16 patients (14%) the GTVpet were larger than GTVct due to multifocal manifestations in the laryngo-pharyngeal regions (4 cases) or lymph node metastases (12 cases). In the majority of the cases (82 pts, 72%) PET/CT-based conturing resulted in remarkable decrease in the volume (15-20%: 4 cases, 20-50%: 46 cases, >50%: 32 cases). On the basis of the initial and post-ICT PET/CT comparison in 15/20 patients more than 50% volume reduction and in 6/20 cases complete response were achieved. After an average of 6.4 years of follow-up the OS (median: 18.3±2.6 months) and DSS (median: 25.0±4.0 months) exhibited close correlation (p=0.0001) to the GTVpet. In cases with GTVpet <10 cm3 prior to RT, DSS did not reach the median, the mean is 82.1±6.1 months, while in cases with GTVpet 10-40 cm3 the median of the DSS was 28.8±4.9 months (HR = 3.57; 95% CI: 1.5-8.3), and in those with GTVpet >40 cm3 the median DSS was 8.4±0.96 months (HR= 11.48; 95% CI: 5.3-24.9). Our results suggest that 18FDG-PET/CT plays an important role for patient with LAHNSC, by modifying the treatment concept and improving the target definition for selective RT modalities. Volumetric PET/CT-based assessment of the tumor response after ICT gives valuable contribution to further therapy planning.
McGrew, Patrick R; Chestovich, Paul J; Fisher, Jay D; Kuhls, Deborah A; Fraser, Douglas R; Patel, Purvi P; Katona, Chad W; Saquib, Syed; Fildes, John J
2018-05-04
Computed Tomography (CT) scans are useful in the evaluation of trauma patients, but are costly and pose risks from ionizing radiation in children. Recent literature has demonstrated the utility of CT scan guidelines in the management of pediatric trauma. This study objective is to review our treatment of pediatric blunt trauma patients and evaluate CT utilization before and after CT-guideline implementation. Our Pediatric Level 2 Trauma Center (TC) implemented a CT scan practice guideline for pediatric trauma patients in March 2014. The guideline recommended for or against CT of the head and abdomen/pelvis utilizing published criteria from the Pediatric Emergency Care and Research Network (PECARN). There was no chest CT guideline. We reviewed all pediatric trauma patients for CT scans obtained during initial evaluation before and after guideline implementation, excluding inpatient scans. The Trauma Registry Database was queried to include all pediatric (age<15) trauma patients seen in our TC from 2010-2016, excluding penetrating mechanism and deaths in the TC. Scans were considered positive if organ injury was detected. Primary outcome was the proportion of patients undergoing CT and percent positive CTs. Secondary outcomes were hospital length of stay (LOS), readmissions, and mortality. Categorical and continuous variables were analyzed with Chi-square and Wilcoxon rank-sum tests, respectively. P<0.05 was considered significant. We identified 1934 patients: 1106 pre- and 828 post-guideline. Absolute reductions in head, chest, and abdomen/pelvis CT scans were 17.7%, 11.5%, and 18.8% respectively (p<0.001). Percent positive head CTs were equivalent, but percent positive chest and abdomen CT increased after implementation. Secondary outcomes were unchanged. Implementation of a pediatric CT guideline significantly decreases CT utilization, reducing the radiation exposure without a difference in outcome. Trauma centers treating pediatric patients should adopt similar guidelines to decrease unnecessary CT scans in children. Level IV, Therapeutic Study.
Automated quantitative 3D analysis of aorta size, morphology, and mural calcification distributions.
Kurugol, Sila; Come, Carolyn E; Diaz, Alejandro A; Ross, James C; Kinney, Greg L; Black-Shinn, Jennifer L; Hokanson, John E; Budoff, Matthew J; Washko, George R; San Jose Estepar, Raul
2015-09-01
The purpose of this work is to develop a fully automated pipeline to compute aorta morphology and calcification measures in large cohorts of CT scans that can be used to investigate the potential of these measures as imaging biomarkers of cardiovascular disease. The first step of the automated pipeline is aorta segmentation. The algorithm the authors propose first detects an initial aorta boundary by exploiting cross-sectional circularity of aorta in axial slices and aortic arch in reformatted oblique slices. This boundary is then refined by a 3D level-set segmentation that evolves the boundary to the location of nearby edges. The authors then detect the aortic calcifications with thresholding and filter out the false positive regions due to nearby high intensity structures based on their anatomical location. The authors extract the centerline and oblique cross sections of the segmented aortas and compute the aorta morphology and calcification measures of the first 2500 subjects from COPDGene study. These measures include volume and number of calcified plaques and measures of vessel morphology such as average cross-sectional area, tortuosity, and arch width. The authors computed the agreement between the algorithm and expert segmentations on 45 CT scans and obtained a closest point mean error of 0.62 ± 0.09 mm and a Dice coefficient of 0.92 ± 0.01. The calcification detection algorithm resulted in an improved true positive detection rate of 0.96 compared to previous work. The measurements of aorta size agreed with the measurements reported in previous work. The initial results showed associations of aorta morphology with calcification and with aging. These results may indicate aorta stiffening and unwrapping with calcification and aging. The authors have developed an objective tool to assess aorta morphology and aortic calcium plaques on CT scans that may be used to provide information about the presence of cardiovascular disease and its clinical impact in smokers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, Lorraine; Cox, Jennifer; Faculty of Health Sciences, University of Sydney, Sydney, New South Wales
2015-09-15
The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 daysmore » post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.« less
Unemo, Magnus; Seth-Smith, Helena M. B.; Cutcliffe, Lesley T.; Skilton, Rachel J.; Barlow, David; Goulding, David; Persson, Kenneth; Harris, Simon R.; Kelly, Anne; Bjartling, Carina; Fredlund, Hans; Olcén, Per; Thomson, Nicholas R.; Clarke, Ian N.
2010-01-01
Chlamydia trachomatis is a major cause of bacterial sexually transmitted infections worldwide. In 2006, a new variant of C. trachomatis (nvCT), carrying a 377 bp deletion within the plasmid, was reported in Sweden. This deletion included the targets used by the commercial diagnostic systems from Roche and Abbott. The nvCT is clonal (serovar/genovar E) and it spread rapidly in Sweden, undiagnosed by these systems. The degree of spread may also indicate an increased biological fitness of nvCT. The aims of this study were to describe the genome of nvCT, to compare the nvCT genome to all available C. trachomatis genome sequences and to investigate the biological properties of nvCT. An early nvCT isolate (Sweden2) was analysed by genome sequencing, growth kinetics, microscopy, cell tropism assay and antimicrobial susceptibility testing. It was compared with relevant C. trachomatis isolates, including a similar serovar E C. trachomatis wild-type strain that circulated in Sweden prior to the initially undetected expansion of nvCT. The nvCT genome does not contain any major genetic polymorphisms – the genes for central metabolism, development cycle and virulence are conserved – or phenotypic characteristics that indicate any altered biological fitness. This is supported by the observations that the nvCT and wild-type C. trachomatis infections are very similar in terms of epidemiological distribution, and that differences in clinical signs are only described, in one study, in women. In conclusion, the nvCT does not appear to have any altered biological fitness. Therefore, the rapid transmission of nvCT in Sweden was due to the strong diagnostic selective advantage and its introduction into a high-frequency transmitting population. PMID:20093289
Initial results from a prototype whole-body photon-counting computed tomography system.
Yu, Z; Leng, S; Jorgensen, S M; Li, Z; Gutjahr, R; Chen, B; Duan, X; Halaweish, A F; Yu, L; Ritman, E L; McCollough, C H
X-ray computed tomography (CT) with energy-discriminating capabilities presents exciting opportunities for increased dose efficiency and improved material decomposition analyses. However, due to constraints imposed by the inability of photon-counting detectors (PCD) to respond accurately at high photon flux, to date there has been no clinical application of PCD-CT. Recently, our lab installed a research prototype system consisting of two x-ray sources and two corresponding detectors, one using an energy-integrating detector (EID) and the other using a PCD. In this work, we report the first third-party evaluation of this prototype CT system using both phantoms and a cadaver head. The phantom studies demonstrated several promising characteristics of the PCD sub-system, including improved longitudinal spatial resolution and reduced beam hardening artifacts, relative to the EID sub-system. More importantly, we found that the PCD sub-system offers excellent pulse pileup control in cases of x-ray flux up to 550 mA at 140 kV, which corresponds to approximately 2.5×10 11 photons per cm 2 per second. In an anthropomorphic phantom and a cadaver head, the PCD sub-system provided image quality comparable to the EID sub-system for the same dose level. Our results demonstrate the potential of the prototype system to produce clinically-acceptable images in vivo .
Initial results from a prototype whole-body photon-counting computed tomography system
NASA Astrophysics Data System (ADS)
Yu, Z.; Leng, S.; Jorgensen, S. M.; Li, Z.; Gutjahr, R.; Chen, B.; Duan, X.; Halaweish, A. F.; Yu, L.; Ritman, E. L.; McCollough, C. H.
2015-03-01
X-ray computed tomography (CT) with energy-discriminating capabilities presents exciting opportunities for increased dose efficiency and improved material decomposition analyses. However, due to constraints imposed by the inability of photon-counting detectors (PCD) to respond accurately at high photon flux, to date there has been no clinical application of PCD-CT. Recently, our lab installed a research prototype system consisting of two x-ray sources and two corresponding detectors, one using an energy-integrating detector (EID) and the other using a PCD. In this work, we report the first third-party evaluation of this prototype CT system using both phantoms and a cadaver head. The phantom studies demonstrated several promising characteristics of the PCD sub-system, including improved longitudinal spatial resolution and reduced beam hardening artifacts, relative to the EID sub-system. More importantly, we found that the PCD sub-system offers excellent pulse pileup control in cases of x-ray flux up to 550 mA at 140 kV, which corresponds to approximately 2.5×1011 photons per cm2 per second. In an anthropomorphic phantom and a cadaver head, the PCD sub-system provided image quality comparable to the EID sub-system for the same dose level. Our results demonstrate the potential of the prototype system to produce clinically-acceptable images in vivo.
NASA Astrophysics Data System (ADS)
Wu, T. Y.; Lin, S. F.
2013-10-01
Automatic suspected lesion extraction is an important application in computer-aided diagnosis (CAD). In this paper, we propose a method to automatically extract the suspected parotid regions for clinical evaluation in head and neck CT images. The suspected lesion tissues in low contrast tissue regions can be localized with feature-based segmentation (FBS) based on local texture features, and can be delineated with accuracy by modified active contour models (ACM). At first, stationary wavelet transform (SWT) is introduced. The derived wavelet coefficients are applied to derive the local features for FBS, and to generate enhanced energy maps for ACM computation. Geometric shape features (GSFs) are proposed to analyze each soft tissue region segmented by FBS; the regions with higher similarity GSFs with the lesions are extracted and the information is also applied as the initial conditions for fine delineation computation. Consequently, the suspected lesions can be automatically localized and accurately delineated for aiding clinical diagnosis. The performance of the proposed method is evaluated by comparing with the results outlined by clinical experts. The experiments on 20 pathological CT data sets show that the true-positive (TP) rate on recognizing parotid lesions is about 94%, and the dimension accuracy of delineation results can also approach over 93%.
Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A
2015-09-01
The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.
Telander, R L; Zimmerman, D; van Heerden, J A; Sizemore, G W
1986-12-01
Children with multiple endocrine neoplasia type 2 (MEN2) often develop medullary carcinoma of the thyroid (MCT) or its precursor, C-cell hyperplasia. Survival results are improved if malignancy is diagnosed early from the results of plasma immunoreactive calcitonin (iCT) measurement. The effect of early detection and thyroidectomy in children with MEN2 syndrome was determined by reviewing the experience between 1975 and 1985. Seventeen children with MEN2 who were 12 years old or younger underwent a total thyroidectomy for MCT or C-cell hyperplasia. iCT was measured in all patients preoperatively and postoperatively. Of the 17 children, 14 (82%) had MEN2a and 3 (18%) had MEN2b. There were 14 (82%) female and three (18%) male patients; their mean age was 6.97 years (range 1.5 to 12 years). In all patients, the diagnosis of MCT was made from initial elevated levels of iCT after stimulation with pentagastrin. Three patients had clinical evidence of disease preoperatively. All patients underwent a total thyroidectomy and lymph nodes were removed from the central zone; a neck dissection was performed in the three with clinically obvious disease. MCT with C-cell hyperplasia was found in 11 children and C-cell hyperplasia alone in six. Of the 11 with carcinoma, eight had bilateral disease and three unilateral. Six children had bilateral C-cell hyperplasia. All 17 children were alive and feeling well at the time of this report; however, three had evidence of metastatic disease according to iCT measurements. None of the children had recurrent nerve injuries; one had evidence of hypoparathyroidism.(ABSTRACT TRUNCATED AT 250 WORDS)
Baum, Richard P.; Kulkarni, Harshad R.; Singh, Aviral; Kaemmerer, Daniel; Mueller, Dirk; Prasad, Vikas; Hommann, Merten; Robiller, Franz C.; Niepsch, Karin; Franz, Holger; Jochems, Arthur; Lambin, Philippe; Hörsch, Dieter
2018-01-01
Introduction Peptide receptor radionuclide therapy (PRRT) of patients with somatostatin receptor expressing neuroendocrine neoplasms has shown promising results in clinical trials and a recently published phase III study. Methods In our center, 2294 patients were screened between 2004 and 2014 by 68Ga somatostatin receptor (SSTR) PET/CT. Intention to treat analysis included 1048 patients, who received at least one cycle of 90Yttrium or 177Lutetium-based PRRT. Progression free survival was determined by 68Ga SSTR-PET/CT and EORTC response criteria. Adverse events were determined by CTCAE criteria. Results Overall survival (95% confidence interval) of all patients was 51 months (47.0-54.9) and differed significantly according to radionuclide, grading, previous therapies, primary site and functionality. Progression free survival (based on PET/CT) of all patients was 19 months (16.9-21), which was significantly influenced by radionuclide, grading, and origin of neuroendocrine neoplasm. Progression free survival after initial progression and first and second resumption of PRRT after therapy-free intervals of more than 6 months were 11 months (9.4-12.5) and 8 months (6.4-9.5), respectively. Myelodysplastic syndrome or leukemia developed in 22 patients (2.1%) and 5 patients required hemodialysis after treatment, other adverse events were rare. Conclusion PRRT is effective and overall survival is favorable in patients with neuroendocrine neoplasms depending on the radionuclide used for therapy, grading and origin of the neuroendocrine neoplasm which is not exactly mirrored in progression free survival as determined by highly sensitive 68Ga somatostatin receptor PET/CT using EORTC criteria for determining response to therapy. PMID:29682195
Klotz, Matthias C M; Beckmann, Nicholas A; Bitsch, Rudi G; Seebach, Elisabeth; Reiner, Tobias; Jäger, Sebastian
2014-11-13
In cases of poor bone quality, intraoperative torque measurement might be an alternative to preoperative dual-energy X-ray absorptiometry (DXA) to assess bone quality in total hip arthroplasty (THA). Trabecular peak torque measurement was applied in 14 paired fresh frozen human femurs. Here, a 6.5 × 23 mm wingblade was inserted into the proximal femur without harming the lateral cortical bone. Further tests of the proximal femur also evaluated bone strength (DXA, micro-computed tomography (μCT), monoaxial compression test), and the results were compared to the trabecular torque measurement. Student's t-test was used to compare the values of the groups. Pearson product-moment was applied to correlate the values of the peak torque measurement with the bone strength measured by DXA, μCT, and monoaxial compression test. In the femoral head, the mean trabecular peak torque was 4.38 ± 1.86 Nm. These values showed a strong correlation with the values of the DXA, the μCT, and the biomechanical load test (Pearson's product-moment: DXA: 0.86, μCT-BMD: 0.80, load test: 0.85). Furthermore, the torque measurement showed a more pronounced correlation with the biomechanical load test compared to the DXA. The use of this method provides highly diagnostic information about bone quality. Since the approach was adjusted for THA, no harm of the lateral bone stock will result from this measurement during surgery. The results of this initial study employing small sample sizes indicate that this new method is as sensitive as DXA in predicting bone quality and may function as an intraoperative alternative to DXA in THA. Nevertheless, before this method will turn into clinical use, more research and clinical trials are necessary.
TH-AB-207A-01: Contrast-Enhanced CT: Correlation of Radiation Dose and Biological Effect
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abadi, E; Sanders, J; Agasthya, G
2016-06-15
Purpose: The potential risk from CT is generally characterized in terms of radiation dose. The presence of iodinated-contrast medium increases radiation dose. However, it is unclear how much of this increase is biologically relevant. The purpose of this study was to establish the contribution of dose increase from iodine to biological effect. Methods: Radiation organ dose was estimated in 58 human (XCAT) phantoms “undergoing” chest CT examination (120 kVp, 9 mGy CTDI) on a simulated CT system (Definition Flash, Siemens) with and without iodinated-contrast agent (62.5 mL of iodine per subject). The dose without and with the presence of iodinemore » was compared to the increase in foci per cell (a surrogate of DNA damage) measured before and after similar CT exams without and with contrast agent (Piechowiak et al. 2015). The data were analyzed to ascertain how the enhancement in biological effect in contrast-enhanced CTs correlated with the increase in dose due to the presence of iodine. Results: The presence of iodinated-contrast in CT increased the organ doses by 2% to 50% on average. Typical values were heart (50%±7%), kidney (19%±7%), and liver (2%±3%). The corresponding increase in the average foci per cell was 107%±19%, indicating biological effect of iodine was greater than what would be anticipated from the iodine-initiated increase in radiation dose alone. Conclusion: Mean foci per cell and organ dose both increase in the presence of contrast agent. The former, however, is at least twice as large as the latter, indicating that iodine contributes to an increase in the probability of DNA damage not only as a consequence of increased x-ray energy deposition but also from other mechanisms. Hence iodine radiation dose, while relevant to be included in estimating the risk associated with contrast-enhanced CT, still can underestimate the biological effects.« less
NASA Astrophysics Data System (ADS)
Azizian, Mohammad F.; Semprini, Lewis
2016-07-01
Tetrachloroethene (PCE) and carbon tetrachloride (CT) were simultaneously transformed in a packed column that was bioaugmented with the Evanite culture (EV). The data presented here have been obtained over a period of 1930 days. Initially the column was continuously fed synthetic groundwater with PCE (0.1 mM), sulfate (SO42 -) (0.2 mM) and formate (2.1 mM) or lactate (1.1 mM), but not CT. In these early stages of the study the effluent H2 concentrations ranged from 7 to 19 nM, and PCE was transformed to ethene (ETH) (81 to 85%) and vinyl chloride (VC) (11 to 17%), and SO42 - was completely reduced when using either lactate or formate as electron donors. SO42 - reduction occurred concurrently with cis-DCE and VC dehalogenation. Formate was a more effective substrate for promoting dehalogenation based on electron donor utilization efficiency. Simultaneous PCE and CT tests found CT (0.015 mM) was completely transformed with 20% observed as chloroform (CF) and trace amounts of chloromethane (CM) and dichloromethane (DCM), but no methane (CH4) or carbon disulfide (CS2). PCE transformation to ETH improved with CT addition in response to increases in H2 concentrations to 160 nM that resulted from acetate formation being inhibited by either CT or CF. Lactate fermentation was negatively impacted after CT transformation tests, with propionate accumulating, and H2 concentrations being reduced to below 1 nM. Under these conditions both SO42 - reduction and dehalogenation were negatively impacted, with sulfate reduction not occurring and PCE being transformed to cis-dichloroethene (c-DCE) (52%) and VC (41%). Upon switching to formate, H2 concentrations increased to 40 nM, and complete SO42 - reduction was achieved, while PCE was transformed to ETH (98%) and VC (1%), with no acetate detected. Throughout the study PCE dehalogenation to ethene was positively correlated with the effluent H2 concentrations.
Tamm, Alexander S; Abele, Jonathan T
2017-02-01
Spondylodiscitis has historically been a difficult clinical diagnosis. Two imaging techniques that address this problem are magnetic resonance imaging (MRI) and combined bone ( 99m Tc-methylene diphosphonate) and gallium-67 single-photon emission computed tomography-computed tomography (SPECT-CT). Their accuracies have not been adequately compared. The purpose of this study is to compare the sensitivities and specificities of bone and gallium SPECT-CT and MRI in infectious spondylodiscitis. This retrospective study assessed all patients who underwent a bone or gallium SPECT-CT of the spine to assess for infectious spondylodiscitis from January 1, 2010, to May 2, 2012, at a single tertiary care centre. Thirty-four patients (23 men; average 62 ± 14 years of age) were included. The results of the bone or gallium SPECT-CT were compared against MRI for all patients in the cohort who underwent an MRI within 12 weeks of the SPECT-CT. A diagnosis of spondylodiscitis in the discharge summary was considered the reference standard, and was based on a combination of clinical scenario, response to therapy, imaging, or microbiology. Spondylodiscitis was diagnosed in 18 patients and excluded in 16. Bone or gallium SPECT-CT and MRI had similar (P > .05; κ = 0.74) sensitivities (0.94 vs 0.94), specificities (1.00 vs 1.00), positive predictive values (1.00 vs 1.00), negative predictive values (0.94 vs 0.80), and accuracies (0.97 vs 0.95) when compared to the reference standard. Although MRI remains the initial modality of choice in diagnosing spondylodiscitis, bone and gallium SPECT-CT appears diagnostically equivalent and should be considered a viable supplementary or alternative imaging modality particularly if there is contraindication or inaccessibility to MRI. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Follow-up segmentation of lung tumors in PET and CT data
NASA Astrophysics Data System (ADS)
Opfer, Roland; Kabus, Sven; Schneider, Torben; Carlsen, Ingwer C.; Renisch, Steffen; Sabczynski, Jörg
2009-02-01
Early response assessment of cancer therapy is a crucial component towards a more effective and patient individualized cancer therapy. Integrated PET/CT systems provide the opportunity to combine morphologic with functional information. We have developed algorithms which allow the user to track both tumor volume and standardized uptake value (SUV) measurements during the therapy from series of CT and PET images, respectively. To prepare for tumor volume estimation we have developed a new technique for a fast, flexible, and intuitive 3D definition of meshes. This initial surface is then automatically adapted by means of a model-based segmentation algorithm and propagated to each follow-up scan. If necessary, manual corrections can be added by the user. To determine SUV measurements a prioritized region growing algorithm is employed. For an improved workflow all algorithms are embedded in a PET/CT therapy monitoring software suite giving the clinician a unified and immediate access to all data sets. Whenever the user clicks on a tumor in a base-line scan, the courses of segmented tumor volumes and SUV measurements are automatically identified and displayed to the user as a graph plot. According to each course, the therapy progress can be classified as complete or partial response or as progressive or stable disease. We have tested our methods with series of PET/CT data from 9 lung cancer patients acquired at Princess Margaret Hospital in Toronto. Each patient underwent three PET/CT scans during a radiation therapy. Our results indicate that a combination of mean metabolic activity in the tumor with the PET-based tumor volume can lead to an earlier response detection than a purely volume based (CT diameter) or purely functional based (e.g. SUV max or SUV mean) response measures. The new software seems applicable for easy, faster, and reproducible quantification to routinely monitor tumor therapy.
Extracranial bone metastases from recurrent anaplastic astrocytoma on FDG PET/CT
Li, Zu-Gui; Mu, Hai-Yu
2017-01-01
Abstract Objective: Extracranial bone metastases from astrocytoma are rare and frequently detected as part of multiorgan metastases. It is extremely rare for astrocytoma to have extracranial bone metastases alone. The importance of whole-body fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) imaging in evaluating extracranial metastasis (ECMs) has not been described effectively due to the rarity of this event. The purpose of our case report is to emphasize the role of FDG PET/CT in the assessment of tumor recurrence and extracranial bone metastases from anaplastic astrocytoma. Methods and materials: A 25-year-old woman was firstly admitted with a 4-month history of progressive blurred vision, and 2-month history of intermittent headache. Presurgical MRI imaging revealed a large mass in the left trigone of lateral ventricle. Subsequently, she underwent tumor resection, radiotherapy and chemotherapy. A final pathological diagnosis of anaplastic astrocytoma (WHO III) was made. Nearly 12 months after the surgery, the follow-up brain MR imaging revealed a contrast-enhanced lesion in the site of operative region. Whole-body FDG PET/CT imaging was performed to evaluate the situation. Results: Postoperative brain FDG PET/CT showed an abnormal focal FDG uptake corresponding to the contrast-enhanced lesion in the operative area, suggesting a tumor recurrence. Whole-body FDG PET/CT also showed multiple FDG-avid osteosclerotic lesions in the body. It was highly suggestive of extracranial bone metastases. A subsequent open bone biopsy of FDG-avid lesion in right iliac crest was performed. Histopathological and immunohistochemical findings indicated characteristic of glioma. The patient died 1 month later, nearly 13 months after the initial diagnosis. Conclusions: ECMs from anaplastic astrocytoma are extremely rare but they do occur. Whole-body FDG PET/CT imaging with inclusion of brain was valuable in differentiating tumor recurrence from radiation necrosis and in detecting uncommon extracranial bone metastases from anaplastic astrocytoma, which were closely related to prognosis of this disease. PMID:28591062
SU-D-206-03: Segmentation Assisted Fast Iterative Reconstruction Method for Cone-Beam CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, P; Mao, T; Gong, S
2016-06-15
Purpose: Total Variation (TV) based iterative reconstruction (IR) methods enable accurate CT image reconstruction from low-dose measurements with sparse projection acquisition, due to the sparsifiable feature of most CT images using gradient operator. However, conventional solutions require large amount of iterations to generate a decent reconstructed image. One major reason is that the expected piecewise constant property is not taken into consideration at the optimization starting point. In this work, we propose an iterative reconstruction method for cone-beam CT (CBCT) using image segmentation to guide the optimization path more efficiently on the regularization term at the beginning of the optimizationmore » trajectory. Methods: Our method applies general knowledge that one tissue component in the CT image contains relatively uniform distribution of CT number. This general knowledge is incorporated into the proposed reconstruction using image segmentation technique to generate the piecewise constant template on the first-pass low-quality CT image reconstructed using analytical algorithm. The template image is applied as an initial value into the optimization process. Results: The proposed method is evaluated on the Shepp-Logan phantom of low and high noise levels, and a head patient. The number of iterations is reduced by overall 40%. Moreover, our proposed method tends to generate a smoother reconstructed image with the same TV value. Conclusion: We propose a computationally efficient iterative reconstruction method for CBCT imaging. Our method achieves a better optimization trajectory and a faster convergence behavior. It does not rely on prior information and can be readily incorporated into existing iterative reconstruction framework. Our method is thus practical and attractive as a general solution to CBCT iterative reconstruction. This work is supported by the Zhejiang Provincial Natural Science Foundation of China (Grant No. LR16F010001), National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917).« less
2012-01-01
Background Right ventricular dysfunction (RVD) in acute pulmonary embolism (APE) can be assessed with helical computerized tomography (CT) and transthoracic echocardiography (TTE). Signs of RVD and elevated natriuretic peptides like NT-proBNP and cardiac troponin (TnT) are associated with increased risk of mortality. However, the prognostic role of both initial diagnostic strategy and the use of NT-proBNP and TnT for screening for long-term probability of RVD remains unknown. The aim of the study was to determine the role of helical CT and NT-proBNP in detection of RVD in the acute phase. In addition, the value of NT-proBNP for ruling out RVD at long-term follow-up was assessed. Methods Sixty-three non-high risk APE patients were studied. RVD was assessed at admission in the emergency department by CT and TTE, and both NT-proBNP and TnT samples were taken. These, excepting CT, were repeated seven months later. Results At admission RVD was detected by CT in 37 (59 %) patients. RVD in CT correlated strongly with RVD in TTE (p < 0.0001). NT-proBNP was elevated (≥ 350 ng/l) in 32 (86 %) patients with RVD but in only seven (27 %) patients without RVD (p < 0.0001). All the patients survived until the 7-month follow-up. TTE showed persistent RVD in 6 of 63 (10 %) patients who all had RVD in CT at admission. All of them had elevated NT-proBNP levels in the follow-up compared with 5 (9 %) of patients without RVD (p < 0.0001). Conclusions TTE does not confer further benefit when helical CT is used for screening for RVD in non-high risk APE. All the patients who were found to have RVD in TTE at seven months follow-up had had RVD in the acute phase CT as well. Thus, patients without RVD in diagnostic CT do not seem to require further routine follow-up to screen for RVD later. On the other hand, persistent RVD and thus need for TTE control can be ruled out by assessment of NT-proBNP at follow-up. A follow-up protocol based on these findings is suggested. PMID:22559861
Kwon, Heejin; Cho, Jinhan; Oh, Jongyeong; Kim, Dongwon; Cho, Junghyun; Kim, Sanghyun; Lee, Sangyun; Lee, Jihyun
2015-10-01
To investigate whether reduced radiation dose abdominal CT images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) compromise the depiction of clinically competent features when compared with the currently used routine radiation dose CT images reconstructed with ASIR. 27 consecutive patients (mean body mass index: 23.55 kg m(-2) underwent CT of the abdomen at two time points. At the first time point, abdominal CT was scanned at 21.45 noise index levels of automatic current modulation at 120 kV. Images were reconstructed with 40% ASIR, the routine protocol of Dong-A University Hospital. At the second time point, follow-up scans were performed at 30 noise index levels. Images were reconstructed with filtered back projection (FBP), 40% ASIR, 30% ASIR-V, 50% ASIR-V and 70% ASIR-V for the reduced radiation dose. Both quantitative and qualitative analyses of image quality were conducted. The CT dose index was also recorded. At the follow-up study, the mean dose reduction relative to the currently used common radiation dose was 35.37% (range: 19-49%). The overall subjective image quality and diagnostic acceptability of the 50% ASIR-V scores at the reduced radiation dose were nearly identical to those recorded when using the initial routine-dose CT with 40% ASIR. Subjective ratings of the qualitative analysis revealed that of all reduced radiation dose CT series reconstructed, 30% ASIR-V and 50% ASIR-V were associated with higher image quality with lower noise and artefacts as well as good sharpness when compared with 40% ASIR and FBP. However, the sharpness score at 70% ASIR-V was considered to be worse than that at 40% ASIR. Objective image noise for 50% ASIR-V was 34.24% and 46.34% which was lower than 40% ASIR and FBP. Abdominal CT images reconstructed with ASIR-V facilitate radiation dose reductions of to 35% when compared with the ASIR. This study represents the first clinical research experiment to use ASIR-V, the newest version of iterative reconstruction. Use of the ASIR-V algorithm decreased image noise and increased image quality when compared with the ASIR and FBP methods. These results suggest that high-quality low-dose CT may represent a new clinical option.
Ontogeny of the sheathing leaf base in maize (Zea mays).
Johnston, Robyn; Leiboff, Samuel; Scanlon, Michael J
2015-01-01
Leaves develop from the shoot apical meristem (SAM) via recruitment of leaf founder cells. Unlike eudicots, most monocot leaves display parallel venation and sheathing bases wherein the margins overlap the stem. Here we utilized computed tomography (CT) imaging, localization of PIN-FORMED1 (PIN1) auxin transport proteins, and in situ hybridization of leaf developmental transcripts to analyze the ontogeny of monocot leaf morphology in maize (Zea mays). CT imaging of whole-mounted shoot apices illustrates the plastochron-specific stages during initiation of the basal sheath margins from the tubular disc of insertion (DOI). PIN1 localizations identify basipetal auxin transport in the SAM L1 layer at the site of leaf initiation, a process that continues reiteratively during later recruitment of lateral leaf domains. Refinement of these auxin transport domains results in multiple, parallel provascular strands within the initiating primordium. By contrast, auxin is transported from the L2 toward the L1 at the developing margins of the leaf sheath. Transcripts involved in organ boundary formation and dorsiventral patterning accumulate within the DOI, preceding the outgrowth of the overlapping margins of the sheathing leaf base. We suggest a model wherein sheathing bases and parallel veins are both patterned via the extended recruitment of lateral maize leaf domains from the SAM. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.
Malignant external otitis: the role of computed tomography and radionuclides in evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendelson, D.S.; Som, P.M.; Mendelson, M.H.
1983-12-01
Nine patients with malignant external otitis (MEO) were evaluated with Tc-99m bone scans, Ga-67 citrate scans, pluridirectional tomography, and computed tomographic (CT) scans in order to assess the role of each in the diagnosis and management of MEO. The Tc-99m and Ga-67 citrate scans were the most accurate studies in the initial identification of disease activity, while the return to normal or improvement of the Ga-67 citrate scan has been shown to correlate best with clinical resolution of MEO. CT demonstrated soft-tissue disease and central skull base osteomyelitis better than pluridirectional tomography. CT is excellent for localizing and following themore » progression of bone disease; however, because reossification of the skull base is a very slow process, CT cannot be used to follow accurately regression or inactivity of MEO affecting this area. CT is the best modality for following soft-tissue extension of MEO.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goodsitt, Mitchell M.; Christodoulou, Emmanuel G.; Larson, Sandra C.
2011-04-15
Purpose: This study was performed to investigate the accuracies of the synthesized monochromatic images and effective atomic number maps obtained with the new GE Discovery CT750 HD CT scanner. Methods: A Gammex-RMI model 467 tissue characterization phantom and the CT number linearity section of a Phantom Laboratory Catphan 600 phantom were scanned using the dual energy (DE) feature on the GE CT750 HD scanner. Synthesized monochromatic images at various energies between 40 and 120 keV and effective atomic number (Z{sub eff}) maps were generated. Regions of interest were placed within these images/maps to measure the average monochromatic CT numbers andmore » average Z{sub eff} of the materials within these phantoms. The true Z{sub eff} values were either supplied by the phantom manufacturer or computed using Mayneord's equation. The linear attenuation coefficients for the true CT numbers were computed using the NIST XCOM program with the input of manufacturer supplied elemental compositions and densities. The effects of small variations in the assumed true densities of the materials were also investigated. Finally, the effect of body size on the accuracies of the synthesized monochromatic CT numbers was investigated using a custom lumbar section phantom with and without an external fat-mimicking ring. Results: Other than the Z{sub eff} of the simulated lung inserts in the tissue characterization phantom, which could not be measured by DECT, the Z{sub eff} values of all of the other materials in the tissue characterization and Catphan phantoms were accurate to 15%. The accuracies of the synthesized monochromatic CT numbers of the materials in both phantoms varied with energy and material. For the 40-120 keV range, RMS errors between the measured and true CT numbers in the Catphan are 8-25 HU when the true CT numbers were computed using the nominal plastic densities. These RMS errors improve to 3-12 HU for assumed true densities within the nominal density {+-}0.02 g/cc range. The RMS errors between the measured and true CT numbers of the tissue mimicking materials in the tissue characterization phantom over the 40-120 keV range varied from about 6 HU-248 HU and did not improve as dramatically with small changes in assumed true density. Conclusions: Initial tests indicate that the Z{sub eff} values computed with DECT on this scanner are reasonably accurate; however, the synthesized monochromatic CT numbers can be very inaccurate, especially for dense tissue mimicking materials at low energies. Furthermore, the synthesized monochromatic CT numbers of materials still depend on the amount of the surrounding tissues especially at low keV, demonstrating that the numbers are not truly monochromatic. Further research is needed to develop DE methods that produce more accurate synthesized monochromatic CT numbers.« less
Noh, Seung Yeon; Wilson, Stephanie R; Kono, Yuko; Piscaglia, Fabio; Jang, Hyun-Jung; Lyshchik, Andrej; Dietrich, Christoph F.; Willmann, Juergen K.; Vezeridis, Alexander; Sirlin, Claude B
2017-01-01
Medical imaging plays an important role in the diagnosis and management of hepatocellular carcinoma (HCC). The Liver Imaging Reporting and Data System (LI-RADS) was initially created to standardize the reporting and data collection of CT and MR imaging for patients at risk for HCC. As contrast-enhanced ultrasound (CEUS) has been widely used in clinical practice, it has recently been added to the LI-RADS. While CEUS LI-RADS shares fundamental concepts with CT/MRI LI-RADS, there are key differences between the modalities reflecting dissimilarities in the underlying methods of image acquisition and types of contrast material. This review introduces a recent update of CEUS LI-RADS and explains the key differences from CT/MRI LI-RADS. PMID:28911220