Sample records for ct showed diffuse

  1. Pulmonary effects of synthetic marijuana: chest radiography and CT findings.

    PubMed

    Berkowitz, Eugene A; Henry, Travis S; Veeraraghavan, Srihari; Staton, Gerald W; Gal, Anthony A

    2015-04-01

    The purpose of this article is to present the first chest radiographic and CT descriptions of organizing pneumonia in response to smoking synthetic marijuana. Chest radiographs showed a diffuse miliary-micronodular pattern. Chest CT images showed diffuse centrilobular nodules and tree-in-bud pattern and a histopathologic pattern of organizing pneumonia with or without patchy acute alveolar damage. This distinct imaging pattern should alert radiologists to include synthetic marijuana abuse in the differential diagnosis.

  2. Benign and malignant skull-involved lesions: discriminative value of conventional CT and MRI combined with diffusion-weighted MRI.

    PubMed

    Tu, Zhanhai; Xiao, Zebin; Zheng, Yingyan; Huang, Hongjie; Yang, Libin; Cao, Dairong

    2018-01-01

    Background Little is known about the value of computed tomography (CT) and magnetic resonance imaging (MRI) combined with diffusion-weighted imaging (DWI) in distinguishing malignant from benign skull-involved lesions. Purpose To evaluate the discriminative value of DWI combined with conventional CT and MRI for differentiating between benign and malignant skull-involved lesions. Material and Methods CT and MRI findings of 58 patients with pathologically proven skull-involved lesions (43 benign and 15 malignant) were retrospectively reviewed. Conventional CT and MRI characteristics and apparent diffusion coefficient (ADC) value of the two groups were evaluated and compared. Multivariate logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the differential performance of each parameter separately and together. Results The presence of cortical defects or break-through and ill-defined margins were associated with malignant skull-involved lesions (both P < 0.05). Malignant skull-involved lesions demonstrated a significantly lower ADC ( P = 0.016) than benign lesions. ROC curve analyses indicated that a combination of CT, MRI, and DWI with an ADC ≤ 0.703 × 10 -3 mm 2 /s showed optimal sensitivity, while DWI along showed optimal specificity of 88.4% in differentiating between benign and malignant skull-involved lesions. Conclusion The combination of CT, MRI, and DWI can help to differentiate malignant from benign skull-involved lesions. CT + MRI + DWI offers optimal sensitivity, while DWI offers optimal specificity.

  3. IgG4-Related Disease Simulating Carcinoma Colon With Diffuse Peritoneal Carcinomatosis on 18F-FDG PET/CT.

    PubMed

    Vadi, Shelvin Kumar; Parihar, Ashwin Singh; Kumar, Rajender; Singh, Harmandeep; Mittal, Bhagwant Rai; Bal, Amanjit; Sinha, Saroj Kumar

    2018-05-14

    IgG4-related disease (IgG4-RD) continues to be a diagnostic challenge and a great mimicker of malignancies. We report here a case of young man who presented with subacute intestinal obstruction with initial imaging and clinical features suggestive of carcinoma colon. 18F-FDG PET/CT showed diffuse peritoneal carcinomatosis pattern typically seen with abdominal malignancies. However, the histopathology and the raised IgG4 levels diagnosed it to be IgG4-RD. Although 18F-FDG PET/CT has typical patterns corresponding to the multisystemic involvement of IgG4-RD, the index case did not show any such findings.

  4. Clinical utility of FDG PET/CT in acute complicated pyelonephritis-results from an observational study.

    PubMed

    Wan, Chih-Hsing; Tseng, Jing-Ren; Lee, Ming-Hsun; Yang, Lan-Yan; Yen, Tzu-Chen

    2018-03-01

    Acute complicated pyelonephritis (ACP) is an upper urinary tract infection associated with coexisting urinary tract abnormalities or medical conditions that could predispose to serious outcomes or treatment failures. Although CT and magnetic resonance imaging (MRI) are frequently used in patients with ACP, the clinical value of 18 F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) has not been systematically investigated. This single-center retrospective study was designed to evaluate the potential usefulness of FDG PET/CT in patients with ACP. Thirty-one adult patients with ACP who underwent FDG PET/CT were examined. FDG PET/CT imaging characteristics, including tracer uptake patterns, kidney volumes, and extrarenal imaging findings, were reviewed in combination with clinical data and conventional imaging results. Of the 31 patients, 19 (61%) showed focal FDG uptake. The remaining 12 study participants showed a diffuse FDG uptake pattern. After volumetric approximation, the affected kidneys were found to be significantly enlarged. Patients who showed a focal uptake pattern had a higher frequency of abscess formation requiring drainage. ACP patients showing diffuse tracer uptake patterns had a more benign clinical course. Seven patients had suspected extrarenal coinfections, and FDG PET/CT successfully confirmed the clinical suspicion in five cases. FDG PET/CT was as sensitive as CT in identifying the six patients (19%) who developed abscesses. Notably, FDG PET/CT findings caused a modification to the initial antibiotic regimen in nine patients (29%). FDG PET/CT may be clinically useful in the assessment of patients with ACP who have a progressive disease course.

  5. Raman and CT scan mapping of chalcogenide glass diffusion generated gradient index profiles

    NASA Astrophysics Data System (ADS)

    Lindberg, G. P.; Berg, R. H.; Deegan, J.; Benson, R.; Salvaggio, P. S.; Gross, N.; Weinstein, B. A.; Gibson, D.; Bayya, S.; Sanghera, J.; Nguyen, V.; Kotov, M.

    2016-05-01

    Metrology of a gradient index (GRIN) material is non-trivial, especially in the realm of infrared and large refractive index. Traditional methods rely on index matching fluids which are not available for indexes as high as those found in the chalcogenide glasses (2.4-3.2). By diffusing chalcogenide glasses of similar composition one can blend the properties in a continuous way. In an effort to measure this we will present data from both x-ray computed tomography scans (CT scans) and Raman mapping scans of the diffusion profiles. Proof of concept measurements on undiffused bonded sheets of chalcogenide glasses were presented previously. The profiles measured will be of axially stacked sheets of chalcogenide glasses diffused to create a linear GRIN profile and nested tubes of chalcogenide glasses diffused to create a radial parabolic GRIN profile. We will show that the x-ray absorption in the CT scan and the intensity of select Raman peaks spatially measured through the material are indicators of the concentration of the diffusion ions and correlate to the spatial change in refractive index. We will also present finite element modeling (FEM) results and compare them to post precision glass molded (PGM) elements that have undergone CT and Raman mapping.

  6. In vivo tomographic imaging of lung colonization of tumour in mouse with simultaneous fluorescence and X-ray CT.

    PubMed

    Zhang, Bin; Gao, Fuping; Wang, Mengjiao; Cao, Xu; Liu, Fei; Wang, Xin; Luo, Jianwen; Wang, Guangzhi; Bai, Jing

    2014-01-01

    Non-invasive in vivo imaging of diffuse and wide-spread colonization within the lungs, rather than distinct solid primary tumors, is still a challenging work. In this work, a lung colonization mouse model bearing A549 human lung tumor was simultaneously scanned by a dual-modality fluorescence molecular tomography (FMT) and X-ray computed tomography (CT) system in vivo. A two steps method which incorporates CT structural information into the FMT reconstruction procedure is employed to provide concurrent anatomical and functional information. By using the target-specific fluorescence agent, the fluorescence tomographic results show elevated fluorescence intensity deep within the lungs which is colonized with diffuse and wide-spread tumors. The results were confirmed with ex vivo fluorescence reflectance imaging and histological examination of the lung tissues. With FMT reconstruction combined with the CT information, the dual-modality FMT/micro-CT system is expected to offer sensitive and noninvasive imaging of diffuse tumor colonization within the lungs in vivo. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Differential diagnosis of breast masses in South Korean premenopausal women using diffuse optical spectroscopic imaging

    NASA Astrophysics Data System (ADS)

    Leproux, Anaïs; Kim, You Me; Min, Jun Won; McLaren, Christine E.; Chen, Wen-Pin; O'Sullivan, Thomas D.; Lee, Seung-ha; Chung, Phil-Sang; Tromberg, Bruce J.

    2016-07-01

    Young patients with dense breasts have a relatively low-positive biopsy rate for breast cancer (˜1 in 7). South Korean women have higher breast density than Westerners. We investigated the benefit of using a functional and metabolic imaging technique, diffuse optical spectroscopic imaging (DOSI), to help the standard of care imaging tools to distinguish benign from malignant lesions in premenopausal Korean women. DOSI uses near-infrared light to measure breast tissue composition by quantifying tissue concentrations of water (ctH2O), bulk lipid (ctLipid), deoxygenated (ctHHb), and oxygenated (ctHbO2) hemoglobin. DOSI spectral signatures specific to abnormal tissue and absent in healthy tissue were also used to form a malignancy index. This study included 19 premenopausal subjects (average age 41±9), corresponding to 11 benign and 10 malignant lesions. Elevated lesion to normal ratio of ctH2O, ctHHb, ctHbO2, total hemoglobin (THb=ctHHb+ctHbO2), and tissue optical index (ctHHb×ctH2O/ctLipid) were observed in the malignant lesions compared to the benign lesions (p<0.02). THb and malignancy index were the two best single predictors of malignancy, with >90% sensitivity and specificity. Malignant lesions showed significantly higher metabolism and perfusion than benign lesions. DOSI spectral features showed high discriminatory power for distinguishing malignant and benign lesions in dense breasts of the Korean population.

  8. Is 3-Tesla Gd-EOB-DTPA-Enhanced MRI with Diffusion-Weighted Imaging Superior to 64-Slice Contrast-Enhanced CT for the Diagnosis of Hepatocellular Carcinoma?

    PubMed Central

    Maiwald, Bettina; Lobsien, Donald; Kahn, Thomas; Stumpp, Patrick

    2014-01-01

    Objectives To compare 64-slice contrast-enhanced computed tomography (CT) with 3-Tesla magnetic resonance imaging (MRI) using Gd-EOB-DTPA for the diagnosis of hepatocellular carcinoma (HCC) and evaluate the utility of diffusion-weighted imaging (DWI) in this setting. Methods 3-phase-liver-CT was performed in fifty patients (42 male, 8 female) with suspected or proven HCC. The patients were subjected to a 3-Tesla-MRI-examination with Gd-EOB-DTPA and diffusion weighted imaging (DWI) at b-values of 0, 50 and 400 s/mm2. The apparent diffusion coefficient (ADC)-value was determined for each lesion detected in DWI. The histopathological report after resection or biopsy of a lesion served as the gold standard, and a surrogate of follow-up or complementary imaging techniques in combination with clinical and paraclinical parameters was used in unresected lesions. Diagnostic accuracy, sensitivity, specificity, and positive and negative predictive values were evaluated for each technique. Results MRI detected slightly more lesions that were considered suspicious for HCC per patient compared to CT (2.7 versus 2.3, respectively). ADC-measurements in HCC showed notably heterogeneous values with a median of 1.2±0.5×10−3 mm2/s (range from 0.07±0.1 to 3.0±0.1×10−3 mm2/s). MRI showed similar diagnostic accuracy, sensitivity, and positive and negative predictive values compared to CT (AUC 0.837, sensitivity 92%, PPV 80% and NPV 90% for MRI vs. AUC 0.798, sensitivity 85%, PPV 79% and NPV 82% for CT; not significant). Specificity was 75% for both techniques. Conclusions Our study did not show a statistically significant difference in detection in detection of HCC between MRI and CT. Gd-EOB-DTPA-enhanced MRI tended to detect more lesions per patient compared to contrast-enhanced CT; therefore, we would recommend this modality as the first-choice imaging method for the detection of HCC and therapeutic decisions. However, contrast-enhanced CT was not inferior in our study, so that it can be a useful image modality for follow-up examinations. PMID:25375778

  9. Pleural mesothelioma - case report.

    PubMed

    Klawiter, Anna; Damaszke, Tomasz

    2010-10-01

    Pleural mesothelioma is a very rare neoplasm; especially the local form. The diagnostics is difficult and the prognosis unfavourable. We presented a case of a man with dyspnoea and cough. His chest radiogram showed hydrothorax on the left side. Neither the examinations of the pleural liquid, nor the CT-guided fine needle biopsy established the diagnosis. CT showed features suggestive of pleural mesothelioma. The diagnosis was confirmed by thoracoscopy. Although no neoplastic cells were found in the thoracoscopic specimen from the supradiaphragmatic tumor, we assumed that to be a case of a diffuse, primarily local form of mesothelioma. Diagnostics of pleural mesothelioma is very difficult. CT and thoracoscopy seem to be very valuable diagnostic methods. It is worth remembering that pleural mesothelioma can have a local form which may transform into a diffuse one.

  10. CO2 flux monitoring using Continuous Timeseries-Forced Diffusion (CT-FD): Development, Validation

    NASA Astrophysics Data System (ADS)

    McArthur, G. S.; Risk, D. A.; Nickerson, N. R.; Creelman, C. A.; Beltrami, H.

    2009-12-01

    Land-based CO2 flux measurements are a key indicator of the biological, chemical and physical processes occurring in the soil. While highly dense temporal flux measurements can be acquired using Eddy Covariance towers, or flux chambers, the challenge of gathering data that is rich both temporally and spatially persists. Over the past two years we have developed a new technique for measuring soil CO2 fluxes, called continuous timeseries-forced diffusion (CT-FD) attempts to satisfy the need for spatially and temporally rich data. The CT-FD probe consists of a Vaisala CO2 sensor, embodied in a PVC casing, with tear/UV resistant Tyvek membranes at both the inlet and outlet. The probe delivers continuous flux data and can be inexpensively replicated across the landscape.The CT-FD technique works by forcing a known diffusive regime between the soil and the atmosphere, allowing the calculation of fluxes across the soil/atmosphere boundary to be made from; the internal concentration of a CT-FD probe placed at the soil surface; and a common reference probe designed to capture the atmospheric CO2. For every concentration measurement, the difference between the probe and the reference concentration is indicative of a unique flux value. Here we examine properties of the instrument and method, as documented by a long series of developmental studies involving numerical gas transport modeling, laboratory and field experiments. A suite of 1D and 3D modeling experiments were needed to optimize embodiment and geometries of the probe. These show that the probe should have a relatively long collar, with relatively high diffusivity made possible by having large, highly diffusive membranes, both of which help to induce 1D movement of gases into the probe and reduce the lateral diffusion around the probe. Modeling also shows that correction for lateral diffusion is feasible. As for error, sensor error transfers linearly to errors in the flux, and that the sensor can be used in non free-atmospheric environments, for example when snow falls and persists. For calibration purposes we designed and built a flux generator, allowing us to test different mathematical approaches for reliability and calibrations which is done by plotting the known flux against the difference between probe and atmospheric CO2 measurements. Validation of the technique was also carried out in the lab using soil plots in which heating cables drove diurnal microbial CO2 production, and we found CT-FD to have an excellent correspondence with LI-8100, showing similar accuracy and precision. Using CT-FD we performed two extensive winter campaigns and one summer campaign in a salt marsh with both CO2-capable and CH4-capable (METS sensor-based) probes. Here we found the CT-FD capable of long, unattended deployments, continued effectiveness when buried under deep snowpack, exposed to long term freezing temperatures, and heavy rain events.

  11. Optimization of CT image reconstruction algorithms for the lung tissue research consortium (LTRC)

    NASA Astrophysics Data System (ADS)

    McCollough, Cynthia; Zhang, Jie; Bruesewitz, Michael; Bartholmai, Brian

    2006-03-01

    To create a repository of clinical data, CT images and tissue samples and to more clearly understand the pathogenetic features of pulmonary fibrosis and emphysema, the National Heart, Lung, and Blood Institute (NHLBI) launched a cooperative effort known as the Lung Tissue Resource Consortium (LTRC). The CT images for the LTRC effort must contain accurate CT numbers in order to characterize tissues, and must have high-spatial resolution to show fine anatomic structures. This study was performed to optimize the CT image reconstruction algorithms to achieve these criteria. Quantitative analyses of phantom and clinical images were conducted. The ACR CT accreditation phantom containing five regions of distinct CT attenuations (CT numbers of approximately -1000 HU, -80 HU, 0 HU, 130 HU and 900 HU), and a high-contrast spatial resolution test pattern, was scanned using CT systems from two manufacturers (General Electric (GE) Healthcare and Siemens Medical Solutions). Phantom images were reconstructed using all relevant reconstruction algorithms. Mean CT numbers and image noise (standard deviation) were measured and compared for the five materials. Clinical high-resolution chest CT images acquired on a GE CT system for a patient with diffuse lung disease were reconstructed using BONE and STANDARD algorithms and evaluated by a thoracic radiologist in terms of image quality and disease extent. The clinical BONE images were processed with a 3 x 3 x 3 median filter to simulate a thicker slice reconstructed in smoother algorithms, which have traditionally been proven to provide an accurate estimation of emphysema extent in the lungs. Using a threshold technique, the volume of emphysema (defined as the percentage of lung voxels having a CT number lower than -950 HU) was computed for the STANDARD, BONE, and BONE filtered. The CT numbers measured in the ACR CT Phantom images were accurate for all reconstruction kernels for both manufacturers. As expected, visual evaluation of the spatial resolution bar patterns demonstrated that the BONE (GE) and B46f (Siemens) showed higher spatial resolution compared to the STANDARD (GE) or B30f (Siemens) reconstruction algorithms typically used for routine body CT imaging. Only the sharper images were deemed clinically acceptable for the evaluation of diffuse lung disease (e.g. emphysema). Quantitative analyses of the extent of emphysema in patient data showed the percent volumes above the -950 HU threshold as 9.4% for the BONE reconstruction, 5.9% for the STANDARD reconstruction, and 4.7% for the BONE filtered images. Contrary to the practice of using standard resolution CT images for the quantitation of diffuse lung disease, these data demonstrate that a single sharp reconstruction (BONE/B46f) should be used for both the qualitative and quantitative evaluation of diffuse lung disease. The sharper reconstruction images, which are required for diagnostic interpretation, provide accurate CT numbers over the range of -1000 to +900 HU and preserve the fidelity of small structures in the reconstructed images. A filtered version of the sharper images can be accurately substituted for images reconstructed with smoother kernels for comparison to previously published results.

  12. Pleural mesothelioma – case report

    PubMed Central

    Klawiter, Anna; Damaszke, Tomasz

    2010-01-01

    Summary Background: Pleural mesothelioma is a very rare neoplasm; especially the local form. The diagnostics is difficult and the prognosis unfavourable. Case Report: We presented a case of a man with dyspnoea and cough. His chest radiogram showed hydrothorax on the left side. Neither the examinations of the pleural liquid, nor the CT-guided fine needle biopsy established the diagnosis. CT showed features suggestive of pleural mesothelioma. The diagnosis was confirmed by thoracoscopy. Although no neoplastic cells were found in the thoracoscopic specimen from the supradiaphragmatic tumor, we assumed that to be a case of a diffuse, primarily local form of mesothelioma. Conclusions: Diagnostics of pleural mesothelioma is very difficult. CT and thoracoscopy seem to be very valuable diagnostic methods. It is worth remembering that pleural mesothelioma can have a local form which may transform into a diffuse one. PMID:22802809

  13. FDG PET/CT Findings in Primary Diffuse Large B-cell Lymphoma, Leg Type.

    PubMed

    Ni, Chiayi; Lewis, Michael; Berenji, Gholam

    2016-01-01

    A 64-year-old man presented with complaints of worsening left foot pain and swelling. MRI showed a soft tissue mass overlying the dorsolateral aspect of the left foot. Following a 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), the left foot mass was biopsied and pathology indicated a diagnosis of primary diffuse large B-cell lymphoma, leg type (PDLBCL, LT). Review of the PET/CT images demonstrated hypermetabolic activity associated with the left foot mass, multiple subcutaneous nodules/nodes, sclerotic osseous lesions in the lower extremities, and left external iliac/left inguinal lymphadenopathy. At the moment, the patient is undergoing chemotherapy.

  14. 18F-DOPA PET and enhanced CT imaging for congenital hyperinsulinism: initial UK experience from a technologist's perspective.

    PubMed

    Meintjes, Marguerite; Endozo, Raymond; Dickson, John; Erlandsson, Kjel; Hussain, Khalid; Townsend, Caroline; Menezes, Leon; Bomanji, Jamshed

    2013-06-01

    Congenital hyperinsulinism (CHI) is the most common cause of persistent hypoglycaemia in infants and children. Histologically, there are two subgroups, diffuse and focal. The aim of this study was to evaluate the accuracy of (18)F-fluoro-L-dihydroxyphenylalanine ((18)F-DOPA) PET/computed tomography (CT) and contrast-enhanced CT in distinguishing between focal and diffuse lesions in infants with CHI who are unresponsive to medical therapy. In addition, this paper describes the detailed protocol used for imaging and analysis of (18)F-DOPA PET/CT images in our clinical practice. Twenty-two (18)F-DOPA PET/CT and contrast-enhanced CT imaging studies were carried out on 18 consecutive patients (nine boys and nine girls) with CHI (median age, 2 years and 1 month; range, 1-84 months) who had positive dominant ABCC8 mutation genetic results or negative ABCC8/t results but did not respond to first-line medical therapy with high-dose diazoxide. (18)F-DOPA was produced by the cyclotron unit of Woolfson Molecular Imaging Centre, Manchester, and transported to our centre in central London after synthesis and implementation of quality control measures. (18)F-DOPA was administered intravenously at a dose of 4 MBq/kg, and iodine contrast medium was injected intravenously at a dose of 1.5 ml/kg. Single bed position PET/CT images of the pancreas were acquired under light sedation with oral chloral hydrate. Four PET dynamic data acquisition scans were taken 20, 40, 50 and 60 min after injection for a duration of 10 min each. The results were assessed by visual interpretation and quantitative measurements of standardized uptake values (SUVs) in the head, body, and tail of the pancreas. Of the 18 patients, 13 showed diffuse and five showed focal (18)F-DOPA PET pancreatic uptake. Three regions of interest were drawn over the head, body and tail of the pancreas to calculate the SUV(max). Using the formula - highest SUV(max)/next highest SUV(max) - a ratio was calculated. Five patients had an accumulation of F-DOPA in the pancreas and an SUV ratio greater than 1.5, indicating focal disease with an SUV(max) more than 50% higher than that of the unaffected areas of the pancreas. The remaining 13 patients had diffuse accumulation of (18)F-DOPA in the pancreas (SUV ratio<1.3). Using this ratio, a focal lesion can be distinguished from diffuse uptake and normal pancreatic uptake. The sizes of these regions of interest varied according to the age of the child. All patients diagnosed with focal lesions underwent surgery and were cured eventually. Lesions were accurately localized by PET/CT and confirmed by histological results after surgery. Three of these patients had to undergo second (18)F-DOPA scans and second surgeries after unsuccessful excision during their first surgery. Three patients with diffuse disease underwent a partial pancreatectomy, and histological results confirmed diffuse disease. One patient was cured and two remain on high-dose diazoxide therapy because of persistent hypoglycaemia. (18)F-DOPA PET/CT offers excellent differentiation of focal from diffuse CHI, and the contrast-enhanced CT technique permits precise preoperative localization of the lesion and anatomical landmarks.

  15. An unusual case of diffuse large B-cell lymphoma involving the vulva evaluated by 18F-FDG PET/CT.

    PubMed

    Treglia, Giorgio; Paone, Gaetano; Perriard, Ulrike; Ceriani, Luca; Giovanella, Luca

    2014-10-01

    We describe an unusual case of diffuse large B-cell lymphoma involving the vulva detected and staged by F-FDG PET/CT. An 83-year-old female patient with history of endometrial carcinoma underwent F-FDG PET/CT for follow-up. PET/CT detected an area of increased F-FDG uptake corresponding to a vulvar nodule; moderate and diffuse F-FDG uptake in the bone marrow was also evident. Based on these PET/CT findings, the patient underwent biopsy of the vulvar nodule. Histology demonstrated the presence of a diffuse large B-cell lymphoma of the vulva. Bone marrow biopsy was positive for lymphoid infiltration.

  16. The importance of Tc-MAA SPECT/CT for therapy planning of radioembolization in a patient treated with bevacizumab.

    PubMed

    Ahmadzadehfar, Hojjat; Sabet, Amir; Meyer, Carsten; Habibi, Elham; Biersack, Hans-Jürgen; Ezziddin, Samer

    2012-11-01

    A 76-year-old man with colorectal cancer and hepatic metastases was referred to us for radioembolization of the liver. Angiography with 99mTc-MAA SPECT/CT was performed 8 weeks after the discontinuation of bevacizumab. 99mTc-MAA SPECT/CT showed a diffused intrahepatic tracer distribution with no focally accentuated accumulation in the tumorous region. The test was repeated 6 weeks later and Tc-MAA SPECT/CT showed this time a tumor accentuated tracer accumulation in the liver. Subsequently, the patient was treated with resin microspheres. Tc-MAA SPECT/CT allows a better evaluation of intrahepatic tracer accumulation of Tc-MAA and facilitates the determination of the most appropriate treatment time.

  17. Ionising radiation-free whole-body MRI versus (18)F-fluorodeoxyglucose PET/CT scans for children and young adults with cancer: a prospective, non-randomised, single-centre study.

    PubMed

    Klenk, Christopher; Gawande, Rakhee; Uslu, Lebriz; Khurana, Aman; Qiu, Deqiang; Quon, Andrew; Donig, Jessica; Rosenberg, Jarrett; Luna-Fineman, Sandra; Moseley, Michael; Daldrup-Link, Heike E

    2014-03-01

    Imaging tests are essential for staging of children with cancer. However, CT and radiotracer-based imaging procedures are associated with substantial exposure to ionising radiation and risk of secondary cancer development later in life. Our aim was to create a highly effective, clinically feasible, ionising radiation-free staging method based on whole-body diffusion-weighted MRI and the iron supplement ferumoxytol, used off-label as a contrast agent. We compared whole-body diffusion-weighted MRI with standard clinical (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT scans in children and young adults with malignant lymphomas and sarcomas. Whole-body diffusion-weighted magnetic resonance images were generated by coregistration of colour-encoded ferumoxytol-enhanced whole-body diffusion-weighted MRI scans for tumour detection with ferumoxytol-enhanced T1-weighted MRI scans for anatomical orientation, similar to the concept of integrated (18)F-FDG PET/CT scans. Tumour staging results were compared using Cohen's κ statistics. Histopathology and follow-up imaging served as the standard of reference. Data was assessed in the per-protocol population. This study is registered with ClinicalTrials.gov, number NCT01542879. 22 of 23 recruited patients were analysed because one patient discontinued before completion of the whole-body scan. Mean exposure to ionising radiation was 12·5 mSv (SD 4·1) for (18)F-FDG PET/CT compared with zero for whole-body diffusion-weighted MRI. (18)F-FDG PET/CT detected 163 of 174 malignant lesions at 1325 anatomical regions and whole-body diffusion-weighted MRI detected 158. Comparing (18)F-FDG PET/CT to whole-body diffusion-weighted MRI, sensitivities were 93·7% (95% CI 89·0-96·8) versus 90·8% (85·5-94·7); specificities 97·7% (95% CI 96·7-98·5) versus 99·5% (98·9-99·8); and diagnostic accuracies 97·2% (93·6-99·4) versus 98·3% (97·4-99·2). Tumour staging results showed very good agreement between both imaging modalities with a κ of 0·93 (0·81-1·00). No adverse events after administration of ferumoxytol were recorded. Ferumoxytol-enhanced whole-body diffusion-weighted MRI could be an alternative to (18)F-FDG PET/CT for staging of children and young adults with cancer that is free of ionising radiation. This new imaging test might help to prevent long-term side-effects from radiographic staging procedures. Thrasher Research Fund and Clinical Health Research Institute at Stanford University. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Whole-body MRI including diffusion-weighted MRI compared with 5-HTP PET/CT in the detection of neuroendocrine tumors

    PubMed Central

    Carlbom, Lina; Caballero-Corbalán, José; Granberg, Dan; Sörensen, Jens; Eriksson, Barbro; Ahlström, Håkan

    2017-01-01

    Aim We wanted to explore if whole-body magnetic resonance imaging (MRI) including diffusion-weighted (DW) and liver-specific contrast agent-enhanced imaging could be valuable in lesion detection of neuroendocrine tumors (NET). [11C]-5-Hydroxytryptophan positron emission tomography/computed tomography (5-HTP PET/CT) was used for comparison. Materials and methods Twenty-one patients with NET were investigated with whole-body MRI, including DW imaging (DWI) and contrast-enhanced imaging of the liver, and whole-body 5-HTP PET/CT. Seven additional patients underwent upper abdomen MRI including DWI, liver-specific contrast agent-enhanced imaging, and 5-HTP PET/CT. Results There was a patient-based concordance of 61% and a lesion-based concordance of 53% between the modalities. MRI showed good concordance with PET in detecting bone metastases but was less sensitive in detecting metastases in mediastinal lymph nodes. MRI detected more liver metastases than 5-HTP PET/CT. Conclusion Whole-body MRI with DWI did not detect all NET lesions found with whole-body 5-HTP PET/CT. Our findings indicate that MRI of the liver including liver-specific contrast agent-enhanced imaging and DWI could be a useful complement to whole-body 5-HTP PET/CT. PMID:27894208

  19. [A rare form of obstructive pulmonary disease].

    PubMed

    van Loenhout, C J; den Bakker, M A; van Wijsenbeek, M S; Hoek, R A S; van Hal, P Th W

    2016-01-01

    Lymphangioleiomyomatosis (LAM) is characterised by progressive dyspnoea, spontaneous pneumothorax and cystic pulmonary destruction. The disease may show similarities with emphysema clinically, radiologically and on lung function tests. A 44-year-old woman was referred for lung transplantation because of a 6-year history of dyspnoea and severe obstructive pulmonary function disorder with decreased diffusion capacity. Both her relatively young age and the fact that she had never smoked made us doubt the diagnosis 'COPD'. The pulmonary cysts seen on high-resolution CT (HRCT) suggested LAM. This was confirmed when we revised a pulmonary biopsy that had previously been performed. CT investigation should be carried out in patients with severe obstructive pulmonary disease without a risk profile appropriate for COPD. Diffuse, homogenous cysts on CT scan can indicate LAM, particularly in women. Conflict of interest and financial support: none declared.

  20. FDG PET/CT in bone sarcoidosis.

    PubMed

    Grozdic Milojevic, Isidora; Sobic-Saranovic, Dragana; Videnovic-Ivanov, Jelica; Saranovic, Djordjije; Odalovic, Strahinja; Artiko, Vera

    2016-03-29

    Bone sarcoidosis is rare manifestation of disease usually accompanied with pulmonary involvement. Until today, exact prevalence of bone sarcoidosis is not known, since reported prevalence varies widely depending on the studied population and the used diagnostic techniques. To determine the prevalence of bone involvement and distribution pattern in active chronic sarcoidosis by using FDG PET/CT. Between January 2010 and December 2011, 98 patients with chronic sarcoidosis and presence of prolonged symptoms or other findings suggestive of active disease were referred to FDG PET/CT examination. Active disease was found in 82 patients, and they all were screened for presence of bone sarcoidosis on FDG PET/CT. All patients also underwent MDCT and assessment of serum ACE level. Bone sarcoidosis was present in 18/82 patients with active sarcoidosis. FDG uptake in bones was focal in 8 (44.4%), diffuse in 6 (33.3%) and both diffuse and focal in 4 (22.2%) patients. CT indicated bone abnormalities only in 5% patients. Osseous involvement was present in: pelvis (61.1%), vertebrae (44.4%), ribs (27.8%) and bone marrow (16.7%). Some patients had two or more locations of disease. Follow-up FDG PET/CT showed normal findings in two patients, same localization of active disease in four patients and progression of disease in one. In patients with active chronic sarcoidosis 22% of patients had osseous abnormalities on FDG PET/CT that mostly were not detected on CT.

  1. Computed tomography of infantile hepatic hemangioendothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lucaya, J.; Enriquez, G.; Amat, L.

    1985-04-01

    Computed tomography (CT) was performed on five infants with hepatic hemangioendothelioma. Precontrast scans showed solitary or multiple, homogeneous, circumscribed areas with reduced attenuation values. Tiny tumoral calcifications were identified in two patients. Serial scans, after injection of a bolus of contrast material, showed early massive enhancement, which was either diffuse or peripheral. On delayed scans, multinocular tumors became isodense with surrounding liver, while all solitary ones showed varied degrees of centripetal enhancement and persistent central cleftlike unenhanced areas. The authors believe that these CT features are characteristic and obviate arteriographic confirmation.

  2. Primary Uterine Peripheral T-cell Lymphoma

    PubMed Central

    Gong, Jing; Dong, Aisheng; Wang, Yang; Zhang, Xuefeng; Yang, Panpan; Wang, Li; Jing, Wei

    2016-01-01

    Abstract Primary uterine non-Hodgkin's lymphoma is extremely rare accounting for <1% of all extranodal non-Hodgkin's lymphomas. Imaging findings of primary uterine lymphoma have rarely been reported before. We present magnetic resonance imaging (MRI) and fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT findings in a patient with primary uterine peripheral T-cell lymphoma. A 27-year-old female presented with intermittent fever with neutropenia for 7 months. MRI showed an ill-defined mass involved both the uterine corpus and cervix, resulting in diffuse enlargement of the uterus. This mass showed inhomogeneous hypointensity on unenhanced T1-weighted images, hyperintensity on diffusion-weighted imaging, relative hypointensity compared to the surrounding myometrium on T2-weighted images and lower enhancement than the surrounding myometrium on enhanced T1-weighted images. FDG PET/CT showed intense FDG uptake in the thickened wall of the uterine corpus and cervix with SUVmax of 26.9. There were multiple hypermetabolic lymph nodes in the pelvis and retroperitoneum. Uterine curettage and CT-guided biopsy of the uterine mass revealed peripheral T-cell lymphoma. Bone marrow biopsy revealed no evidence of lymphomatous involvement. The imaging and pathologic findings were consistent with primary uterine lymphoma. After 3 circles of chemotherapy, follow-up enhanced MRI showed decreased thickness of the uterine wall. Despite its rarity, primary uterine non-Hodgkin's lymphoma should be taken into consideration when a uterine tumor shows large size, relative hypointesity on both T2-weighted images and enhanced T1-weighted images compared to the surrounding myometrium, and intense FDG uptake on PET/CT. MRI may be helpful for describing the relationship between the tumor and adjacent structures. FDG PET/CT may be useful for tumor detection and staging. PMID:27124063

  3. Diffusion-weighted MRI in intrahepatic bile duct adenoma arising from the cirrhotic liver.

    PubMed

    An, Chansik; Park, Sumi; Choi, Yoon Jung

    2013-01-01

    A 64-year-old male patient with liver cirrhosis underwent a CT study for hepatocellular carcinoma surveillance, which demonstrated a 1.4-cm hypervascular subcapsular tumor in the liver. On gadoxetic acid-enhanced MRI, the tumor showed brisk arterial enhancement and persistent hyperenhancement in the portal phase, but hypointensity in the hepatobiliary phase. On diffusion-weighted MRI, the tumor showed an apparent diffusion coefficient twofold greater than that of the background liver parenchyma, which suggested that the lesion was benign. The histologic diagnosis was intrahepatic bile duct adenoma with alcoholic liver cirrhosis.

  4. Acinar cell carcinoma of the pancreas presenting as diffuse pancreatic enlargement: Two case reports and literature review.

    PubMed

    Luo, Yaping; Hu, Guilan; Ma, Yanru; Guo, Ning; Li, Fang

    2017-09-01

    Pancreatic acinar cell carcinoma (ACC) is a rare malignant tumor of exocrine pancreas. It is typically a well-marginated large solid mass arising in a certain aspect of the pancreas. Diffuse involvement of ACC in the pancreas is very rare, and may simulate pancreatitis in radiological findings. We report 2 cases of ACC presenting as diffuse enlargement of the pancreas due to tumor involvement without formation of a distinct mass. The patients consisted of a 41-year-old man with weight loss and a 77-year-old man who was asymptomatic. Computed tomography (CT) and 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT showed diffuse enlargement of the pancreas forming a sausage-like shape with homogenously increased FDG activity. Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) biopsy of the pancreatic lesion was performed. Histopathology results from the pancreas confirmed the diagnosis of pancreatic ACC. Because diffuse enlargement of the pancreas is a common imaging feature of pancreatitis, recognition of this rare morphologic pattern of ACC is important for radiological diagnosis of this tumor.

  5. Emphysematous cystitis occurred in the case treated with steroid for autoimmune hepatitis.

    PubMed

    Yoshino, Tateki; Ohara, Shinya; Moriyama, Hiroyuki

    2013-01-01

    Emphysematous cystitis is a rare clinically entity, more commonly seen in diabetic, immunocompromised patients, which was characterized by air within the bladder wall and lumen. A 83-year-old woman was introduced to our department with fever elevation and abnormal findings of computed tomography (CT). She took orally prednisolone for autoimmune hepatitis. Pelvic CT revealed diffuse air throughout the bladder wall. Urinalysis showed combined hematuria and pyuria. Escherichia coli was detected in blood culture. Abnormal findings of complete blood count and laboratory examination included an elevated WBC count (12,200/μL), C-reactive protein (11.7 mg/dL), and creatinine (1.07 mg/dL). Cystoscopy confirmed diffuse submucosal emphysema throughout. On the basis of diagnosis with emphysematous cystitis, she was treated with antibiotics based on the results of blood culture and indwelling Foley catheter. After treatment, the improvement of inflammatory findings and submucosal emphysema on cystoscopy and CT were achieved.

  6. Formulation, development and characterization of mucoadhesive film for treatment of vaginal candidiasis.

    PubMed

    Mishra, Renuka; Joshi, Priyanka; Mehta, Tejal

    2016-01-01

    The objective of the present investigation was formulation, optimization and characterization of mucoadhesive film of clotrimazole (CT) which is patient-convenient and provides an effective alternative for the treatment of vaginal candidiasis. CT is an antimycotic drug applied locally for the treatment of vaginal candidiasis. Mucoadhesive vaginal films were prepared by solvent casting technique using hydroxyl propylcellulose and sodium alginate as polymers. Propylene glycol and polyethylene glycol-400 were evaluated as plasticizers. The mucoadhesive vaginal films were evaluated for percentage elongation, tensile strength, folding endurance, drug content, in vitro disintegration time, in vitro dissolution study, swelling index, bioadhesive strength, and diffusion study. Among various permeation enhancers used, isopropyl myristate was found to be suitable. To evaluate the role of the concentration of permeation enhancer and concentration of polymers in the optimization of mucoadhesive vaginal film, 3(2) full factorial design was employed. Optimized batch showed in vitro disintegration time, 18 min; drug content, 99.83%; and tensile strength, 502.1 g/mm(2). In vitro diffusion study showed that 77% drug diffusion occurred in 6 h. This batch was further evaluated by scanning electron microscopy indicating uniformity of the film. In vitro Lactobacillus inhibition and in vitro antifungal activity of optimized batch showed an inhibitory effect against Candida albicans and no effect on Lactobacillus, which is a normal component of vaginal flora. Mucoadhesive vaginal film of CT is an effective dosage form for the treatment of vaginal candidiasis.

  7. Comparison of qualitative and quantitative CT and MRI parameters for monitoring of longitudinal spine involvement in patients with multiple myeloma.

    PubMed

    Horger, M; Fritz, J; Thaiss, W M; Ditt, H; Weisel, K; Haap, M; Kloth, Christopher

    2018-03-01

    To compare qualitative and quantitative computed tomography (CT) and magnetic resonance imaging (MRI) parameters for longitudinal disease monitoring of multiple myeloma (MM) of the axial skeleton. We included 31 consecutive patients (17 m; mean age 59.20 ± 8.08 years) with MM, who underwent all baseline (n = 31) and at least one or more (n = 47) follow-up examinations consisting of multi-parametric non-enhanced whole-body MRI ( WB MRI) and non-enhanced whole-body reduced-dose thin-section MDCT (NEWBMDCT) between 06/2013 and 09/2016. We classified response according to qualitative CT criteria into progression (PD), stable(SD), partial/very good partial (PR/VGPR) and complete response(CR), grouping the latter three together for statistical analysis because CT cannot reliably assess PR and CR. Qualitative MR-response criteria were defined and grouped similarly to CT using longitudinal quantification of signal-intensity changes on T1w/STIR/ T2*w and calculating ADC-values. Standard of reference was the hematological laboratory (M-gradient). Hematological response categories were CR (14/47, 29.7%), PR (2/47, 4.2%), SD (16/47, 34.0%) and PD (15/47, 29.9%). Qualitative-CT-evaluation showed PD in 12/47 (25.5%) and SD/PR/VGPR/CR in 35/47 (74.5%) cases. These results were confirmed by quantitative-CT in all focal lytic lesions (p < 0.001). Quantitative-CT at sites with diffuse bone involvement showed significant increase of maximum bone attenuation (p < 0.001*) and significant decrease of minimal bone (p < 0.002*) in the SD/PR/VGPR/CR group. Qualitative MRI showed PD in 14/47 (29.7%) and SD/PR/VGPR/CR in 33/47 (70.3%). Quantitative MRI diagnosis showed a statistically significant decrease in signal intensity on short tau inversion recovery sequences (STIR) in bone marrow in patients with diffuse bone marrow involvement achieving SD/PR/VGPR/CR (p < 0.001*). Imaging response monitoring using MRI is superior to CT only if qualitative parameters are used, whereas there was no definite benefit from using quantitative parameters with either CT or MRI.

  8. Intratympanic Iodine Contrast Injection Diffuses Across the Round Window Membrane Allowing for Perilymphatic CT Volume Acquisition Imaging.

    PubMed

    Abt, Nicholas B; Lehar, Mohamed; Guajardo, Carolina Trevino; Penninger, Richard T; Ward, Bryan K; Pearl, Monica S; Carey, John P

    2016-04-01

    Whether the round window membrane (RWM) is permeable to iodine-based contrast agents (IBCA) is unknown; therefore, our goal was to determine if IBCAs could diffuse through the RWM using CT volume acquisition imaging. Imaging of hydrops in the living human ear has attracted recent interest. Intratympanic (IT) injection has shown gadolinium's ability to diffuse through the RWM, enhancing the perilymphatic space. Four unfixed human cadaver temporal bones underwent intratympanic IBCA injection using three sequentially studied methods. The first method was direct IT injection. The second method used direct RWM visualization via tympanomeatal flap for IBCA-soaked absorbable gelatin pledget placement. In the third method, the middle ear was filled with contrast after flap elevation. Volume acquisition CT images were obtained immediately postexposure, and at 1-, 6-, and 24-hour intervals. Postprocessing was accomplished using color ramping and subtraction imaging. After the third method, positive RWM and perilymphatic enhancement were observed with endolymph sparing. Gray scale and color ramp multiplanar reconstructions displayed increased signal within the cochlea compared with precontrast imaging. The cochlea was measured for attenuation differences compared with pure water, revealing a preinjection average of -1,103 HU and a postinjection average of 338 HU. Subtraction imaging shows enhancement remaining within the cochlear space, Eustachian tube, middle ear epithelial lining, and mastoid. Iohexol iodine contrast is able to diffuse across the RWM. Volume acquisition CT imaging was able to detect perilymphatic enhancement at 0.5-mm slice thickness. The clinical application of IBCA IT injection seems promising but requires further safety studies.

  9. Gallium uptake in tryptophan-related pulmonary disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, S.M.; Park, C.H.; Intenzo, C.M.

    1991-02-01

    We describe a patient who developed fever, fatigue, muscle weakness, dyspnea, skin rash, and eosinophilia after taking high doses of tryptophan for insomnia for two years. A gallium-67 scan revealed diffuse increased uptake in the lung and no abnormal uptake in the muscular distribution. Bronchoscopy and biopsy confirmed inflammatory reactions with infiltration by eosinophils, mast cells, and lymphocytes. CT scan showed an interstitial alveolar pattern without fibrosis. EMG demonstrated diffuse myopathy. Muscle biopsy from the right thigh showed an inflammatory myositis with eosinophilic and lymphocytic infiltrations.

  10. First CT findings and improvement in GOS and GOSE scores 6 and 12 months after severe traumatic brain injury.

    PubMed

    Corral, Luisa; Herrero, José Ignacio; Monfort, José Luis; Ventura, José Luis; Javierre, Casimiro F; Juncadella, Montserrat; García-Huete, Lucía; Bartolomé, Carlos; Gabarrós, Andreu

    2009-05-01

    To analyse the association between individual initial computerized tomography (CT) scan characteristics and Glasgow Outcome Scale (GOS) and Extended Glasgow Outcome Scale (GOSE) improvement between 6 months and 1 year. Two hundred and twenty-four adult patients with severe traumatic brain injury and Glasgow Coma Scale (GCS) score of 8 or less who were admitted to an intensive care unit were studied. GOS and GOSE scores were obtained 6 and 12 months after injury in 203 subjects. Patients were predominantly male (84%) and median age was 35 years. Traumatic Coma Data Bank (TCDB) CT classification was associated with GOS/GOSE improvement between 6 months and 1 year, with diffuse injury type I, type II and evacuated mass improving more than diffuse injury type III, type IV and non-evacuated mass; for GOS 43/155 (28%) vs 3/48 (6%) (chi(2) = 9.66, p < 0.01) and for GOSE 71/155 (46%) vs 7/48 (15%) (chi(2) = 15.1, p < 0.01). CT individual abnormalities were not associated with GOS/GOSE improvement, with the exception of subarachnoid haemorrhage, which showed a negative association with GOSE improvement (chi(2) = 4.08, p < 0.05). TCDB CT scan classification and subarachnoid haemorrhage were associated with GOS/GOSE improvement from 6-12 months, but individual CT abnormalities were not associated.

  11. Intratympanic Iodine Contrast Injection Diffuses Across the Round Window Membrane Allowing for Perilymphatic CT Volume Acquisition Imaging

    PubMed Central

    Abt, Nicholas B.; Lehar, Mohamed; Guajardo, Carolina Trevino; Penninger, Richard T.; Ward, Bryan K.; Pearl, Monica S.; Carey, John P.

    2016-01-01

    Hypothesis Whether the RWM is permeable to iodine-based contrast agents (IBCA) is unknown; therefore, our goal was to determine if IBCAs could diffuse through the RWM using CT volume acquisition imaging. Introduction Imaging of hydrops in the living human ear has attracted recent interest. Intratympanic (IT) injection has shown gadolinium's ability to diffuse through the round window membrane (RWM), enhancing the perilymphatic space. Methods Four unfixed human cadaver temporal bones underwent intratympanic IBCA injection using three sequentially studied methods. The first method was direct IT injection. The second method used direct RWM visualization via tympanomeatal flap for IBCA-soaked absorbable gelatin pledget placement. In the third method, the middle ear was filled with contrast after flap elevation. Volume acquisition CT images were obtained immediately post-exposure, and at 1, 6, and 24 hour intervals. Post-processing was accomplished using color ramping and subtraction imaging. Results Following the third method, positive RWM and perilymphatic enhancement were seen with endolymph sparing. Gray scale and color ramp multiplanar reconstructions displayed increased signal within the cochlea compared to pre-contrast imaging. The cochlea was measured for attenuation differences compared to pure water, revealing a pre-injection average of −1,103 HU and a post-injection average of 338 HU. Subtraction imaging shows enhancement remaining within the cochlear space, Eustachian tube, middle ear epithelial lining, and mastoid. Conclusions Iohexol iodine contrast is able to diffuse across the RWM. Volume acquisition CT imaging was able to detect perilymphatic enhancement at 0.5mm slice thickness. The clinical application of IBCA IT injection appears promising but requires further safety studies. PMID:26859543

  12. Emphysematous Cystitis Occurred in the Case Treated with Steroid for Autoimmune Hepatitis

    PubMed Central

    Yoshino, Tateki; Ohara, Shinya; Moriyama, Hiroyuki

    2013-01-01

    Emphysematous cystitis is a rare clinically entity, more commonly seen in diabetic, immunocompromised patients, which was characterized by air within the bladder wall and lumen. A 83-year-old woman was introduced to our department with fever elevation and abnormal findings of computed tomography (CT). She took orally prednisolone for autoimmune hepatitis. Pelvic CT revealed diffuse air throughout the bladder wall. Urinalysis showed combined hematuria and pyuria. Escherichia coli was detected in blood culture. Abnormal findings of complete blood count and laboratory examination included an elevated WBC count (12,200/μL), C-reactive protein (11.7 mg/dL), and creatinine (1.07 mg/dL). Cystoscopy confirmed diffuse submucosal emphysema throughout. On the basis of diagnosis with emphysematous cystitis, she was treated with antibiotics based on the results of blood culture and indwelling Foley catheter. After treatment, the improvement of inflammatory findings and submucosal emphysema on cystoscopy and CT were achieved. PMID:23936723

  13. Autoimmune lymphoproliferative syndrome and non-Hodgkin lymphoma: what 18F-fluorodeoxyglucose positron emission tomography/computed tomography can do in the management of these patients? Suggestions from a case report.

    PubMed

    Cistaro, A; Pazè, F; Durando, S; Cogoni, M; Faletti, R; Vesco, S; Vallero, S; Quartuccio, N; Treglia, G; Ramenghi, U

    2014-01-01

    A young patient with undefined autoimmune lymphoproliferative syndrome (ALPS-U) and low back pain underwent a CT and MRI study that showed enhancing vertebral lesions, some pulmonary nodules and diffuse latero-cervical lymphadenopathy. A (18)F-FDG-PET/CT scan showed many areas of intense (18)F-FDG uptake in multiple vertebrae, in some ribs, in the sacrum, in the liver, in both lungs, in multiple lymph nodes spread in the cervical, thoracic and abdominal chains. A bone marrow biopsy showed a "lymphomatoid granulomatosis", a rare variant of B-cell non-Hodgkin lymphoma (NHL). After the treatment, the (18)F-FDG-PET/CT scan showed a complete metabolic response. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  14. Changes over Time in Intracranial Air in Patients with Cerebral Air Embolism: Radiological Study in Two Cases

    PubMed Central

    Kaichi, Yoko; Kakeda, Shingo; Korogi, Yukunori; Nezu, Tomohisa; Aoki, Shiro; Matsumoto, Masayasu; Iida, Makoto; Awai, Kazuo

    2015-01-01

    Cerebral air embolism can be easily identified on computed tomography (CT) scans. However, changes in the distribution and amount of intracranial air are not well known. We report two patients with cerebral air embolism and present imaging findings on the serial changes in the intracranial air. We thought that the embolic source was venous in one patient because CT showed air inflow in cortical veins in the bilateral frontal areas, reflecting air buoyancy. In the other patient, CT showed air inflow into not only the cortical veins but also the bilateral cerebral hemispheres and we thought this to be a paradoxical cerebral air embolism. We found that intracranial air can be promptly absorbed and while cerebral infarcts due to air are clearly visualized on diffusion-weighted images (DWI), the air may rapidly disappear from images. In patients with suspected cerebral air embolism whose CT findings show no intracranial air, DWI should be performed because it may reveal cerebral infarction due to cerebral air embolism. PMID:26640730

  15. Diagnostic capability of gadoxetate disodium-enhanced liver MRI for diagnosis of hepatocellular carcinoma: comparison with multi-detector CT.

    PubMed

    Toyota, Naoyuki; Nakamura, Yuko; Hieda, Masashi; Akiyama, Naoko; Terada, Hiroaki; Matsuura, Noriaki; Nishiki, Masayo; Kono, Hirotaka; Kohno, Hiroshi; Irei, Toshimitsu; Yoshikawa, Yukinobu; Kuraoka, Kazuya; Taniyama, Kiyomi; Awai, Kazuo

    2013-09-01

    The purpose of this study was to evaluate the diagnostic capability of gadoxetate disodium (Gd-EOB)-MRI for the detection of hepatocellular carcinoma (HCC) compared with multidetector CT (MDCT). Fifty patients with 57 surgically proven HCCs who underwent Gd-EOB-MRI and MDCT from March 2008 to June 2011 were evaluated. Two observers evaluated MR and CT on a lesion-by-lesion basis. We analyzed sensitivity by grading on a 5-point scale, the degree of arterial enhancement and the differences in histological grades in the diffusion-weighted images (DWI). The results showed that the sensitivity of Gd-EOB-MRI was higher than that of MDCT especially for HCCs that were 1 cm in diameter or smaller. The hepatobiliary phase was useful for the detecting of small HCC. We had few cases in which it was difficult to judge HCC in the arterial enhancement between MRI and MDCT. In the diffusion-weighted image, well differentiated HCC tended to show a low signal intensity, and poorly differentiated HCC tended to show a high signal intensity. In moderately differentiated HCC's, the mean diameter of the high signal intensity group was larger than that of the low signal intensity group (24.5 mm vs. 15.8 mm). In conclusion, Gd-EOB-MRI tended to show higher sensitivity compared to MDCT in the detection of HCC.

  16. Molecular imaging of malignant tumor metabolism: whole-body image fusion of DWI/CT vs. PET/CT.

    PubMed

    Reiner, Caecilia S; Fischer, Michael A; Hany, Thomas; Stolzmann, Paul; Nanz, Daniel; Donati, Olivio F; Weishaupt, Dominik; von Schulthess, Gustav K; Scheffel, Hans

    2011-08-01

    To prospectively investigate the technical feasibility and performance of image fusion for whole-body diffusion-weighted imaging (wbDWI) and computed tomography (CT) to detect metastases using hybrid positron emission tomography/computed tomography (PET/CT) as reference standard. Fifty-two patients (60 ± 14 years; 18 women) with different malignant tumor disease examined by PET/CT for clinical reasons consented to undergo additional wbDWI at 1.5 Tesla. WbDWI was performed using a diffusion-weighted single-shot echo-planar imaging during free breathing. Images at b = 0 s/mm(2) and b = 700 s/mm(2) were acquired and apparent diffusion coefficient (ADC) maps were generated. Image fusion of wbDWI and CT (from PET/CT scan) was performed yielding for wbDWI/CT fused image data. One radiologist rated the success of image fusion and diagnostic image quality. The presence or absence of metastases on wbDWI/CT fused images was evaluated together with the separate wbDWI and CT images by two different, independent radiologists blinded to results from PET/CT. Detection rate and positive predictive values for diagnosing metastases was calculated. PET/CT examinations were used as reference standard. PET/CT identified 305 malignant lesions in 39 of 52 (75%) patients. WbDWI/CT image fusion was technically successful and yielded diagnostic image quality in 73% and 92% of patients, respectively. Interobserver agreement for the evaluation of wbDWI/CT images was κ = 0.78. WbDWI/CT identified 270 metastases in 43 of 52 (83%) patients. Overall detection rate and positive predictive value of wbDWI/CT was 89% (95% CI, 0.85-0.92) and 94% (95% CI, 0.92-0.97), respectively. WbDWI/CT image fusion is technically feasible in a clinical setting and allows the diagnostic assessment of metastatic tumor disease detecting nine of 10 lesions as compared with PET/CT. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  17. Diagnosis of complications associated with acute cholecystitis using computed tomography and diffusion-weighted imaging with background body signal suppression/T2 image fusion.

    PubMed

    Tomizawa, Minoru; Shinozaki, Fuminobu; Tanaka, Satomi; Sunaoshi, Takafumi; Kano, Daisuke; Sugiyama, Eriko; Shite, Misaki; Haga, Ryouta; Fukamizu, Yoshiya; Fujita, Toshiyuki; Kagayama, Satoshi; Hasegawa, Rumiko; Shirai, Yoshinori; Motoyoshi, Yasufumi; Sugiyama, Takao; Yamamoto, Shigenori; Ishige, Naoki

    2017-07-01

    In a clinical setting, it is important to diagnose complications of acute cholecystitis accurately. Diffusion-weighted whole body imaging with background body signal suppression/T2-weighted image fusion (DWIBS/T2) provides high signal intensity with a strong contrast against surrounding tissues in anatomical settings. In the present study, patients who were being treated for acute cholecystitis and underwent DWIBS/T2 in the National Hospital Organization Shimoshizu Hospital between December 2012 and August 2015 were enrolled. A total of 10 men and 4 women underwent DWIBS/T2. Records, including DWIBS/T2 and computed tomography (CT) imaging, were retrospectively analyzed for patients with acute cholecystitis. CT images revealed thickened gallbladder walls in patients with acute cholecystitis, and high signal intensity was observed in DWIBS/T2 images for the thickened gallbladder wall. Inflammation of the pericholecystic space and the liver resulted in high intensity signals with DWIBS/T2 imaging, whereas CT imaging revealed a low-density area in the cholecystic space. Plain CT scanning identified a low-density area in the liver, which became more obvious with contrast-enhanced CT. DWIBS/T2 imaging showed the inflammation of the liver and pericholesyctic space as an area of high signal intensity. Detectability of inflammation of the pericholecystic space and the liver was the same for DWIBS/T2 and CT, which suggests that DWIBS/T2 has the same sensitivity as CT scanning for the diagnosis of complicated acute cholecystitis. However, the strong contrast shown by DWIBS/T2 allows for easier evaluation of acute cholecystitis than CT scanning.

  18. Postmortem CT investigation of air/gas distribution in the lungs and gastrointestinal tracts of newborn infants: a serial case study with regard to still- and live birth.

    PubMed

    Michiue, Tomomi; Ishikawa, Takaki; Kawamoto, Osamu; Sogawa, Nozomi; Oritani, Shigeki; Maeda, Hitoshi

    2013-03-10

    Flotation tests on the lungs and gastrointestinal tract to investigate aeration are classic procedures to examine the life of a newborn after birth; however, there are arguments about the reliability. The present study investigated serial forensic autopsy cases of newborn infants without marked decomposition (n=4) with regard to air/gas distribution in the lungs and gastrointestinal tracts by means of postmortem CT (PM-CT) as well as macromorphology and histology, compared with intrauterine and aborted fetuses (n=3). No gas was detected in the lungs or gastrointestinal tracts in all of three intrauterine fetal deaths. Gas was diffusely detected in the lungs of a newborn fatality attributed to smothering after birth; however, two neonatal fatalities had poor lung gas contents due to marked congestion with edema and diffuse atelectasis. In a case of unsuccessful cardiopulmonary resuscitation following possible birth asphyxia, pulmonary aeration was evidently localized on CT morphology, despite a larger amount of bowel gas, and was also uneven in histology, showing a membranous immunostaining pattern of pulmonary surfactant on the intra-alveolar surfaces of expanded alveoli. The combined use of PM-CT is useful to demonstrate air/gas distributions in the lungs and gastrointestinal tract for interpretation of spontaneous breathing after birth in newborn fatalities. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Correlation of simultaneously acquired diffusion-weighted imaging and 2-deoxy-[18F] fluoro-2-D-glucose positron emission tomography of pulmonary lesions in a dedicated whole-body magnetic resonance/positron emission tomography system.

    PubMed

    Schmidt, Holger; Brendle, Cornelia; Schraml, Christina; Martirosian, Petros; Bezrukov, Ilja; Hetzel, Jürgen; Müller, Mark; Sauter, Alexander; Claussen, Claus D; Pfannenberg, Christina; Schwenzer, Nina F

    2013-05-01

    Hybrid whole-body magnetic resonance/positron emission tomography (MR/PET) systems are a new diagnostic tool enabling the simultaneous acquisition of morphologic and multiple functional data and thus allowing for a diversified characterization of oncological diseases.The aim of this study was to investigate the image and alignment quality of MR/PET in patients with pulmonary lesions and to compare the congruency of the 2 functional measurements of diffusion-weighted imaging (DWI) in MR imaging and 2-deoxy-[18F] fluoro-2-D-glucose (FDG) uptake in PET. A total of 15 patients were examined with a routine positron emission tomography/computer tomography (PET/CT) protocol and, subsequently, in a whole-body MR/PET scanner allowing for simultaneous PET and MR data acquisition. The PET and MR image quality was assessed visually using a 4-point score (1, insufficient; 4, excellent). The alignment quality of the rigidly registered PET/CT and MR/PET data sets was investigated on the basis of multiple anatomic landmarks of the lung using a scoring system from 1 (no alignment) to 4 (very good alignment). In addition, the alignment quality of the tumor lesions in PET/CT and MR/PET as well as for retrospective fusion of PET from PET/CT and MR images was assessed quantitatively and was compared between lesions strongly or less influenced by respiratory motion. The correlation of the simultaneously acquired DWI and FDG uptake in the pulmonary masses was analyzed using the minimum and mean apparent diffusion coefficient (ADC min and ADC mean) as well as the maximum and mean standardized uptake value (SUV max and SUV mean), respectively. In addition, the correlation of SUV max from PET/CT data was investigated as well. On lesions 3 cm or greater, a voxelwise analysis of ADC and SUV was performed. The visual evaluation revealed excellent image quality of the PET images (mean [SD] score, 3.6 [0.5]) and overall good image quality of DWI (mean [SD] score of 2.5 [0.5] for ADC maps and 2.7 [0.5] for diffusion-weighted images, respectively). The alignment quality of the data sets was very good in both MR/PET and PET/CT without significant differences (overall mean [SD] score of MR/PET, 3.8 [0.4]; PET/CT 3.6 [0.5]). Also, the alignment quality of the tumor lesions showed no significant differences between PET/CT and MR/PET (mean cumulative misalignment of MR/PET, 7.7 mm; PET/CT, 7.0 mm; P = 0.705) but between both modalities and a retrospective fusion (mean cumulative misalignment, 17.1 mm; P = 0.002 and P = 0.008 for PET/CT and MR/PET, respectively). Also, the comparison of the lesions strongly or less influenced by respiratory motion showed significant differences only for the retrospective fusion (21.3 mm vs 11.5 mm, respectively; P = 0.043). The ADC min and SUV max as measures of the cell density and glucose metabolism showed a significant reverse correlation (r = -0.80; P = 0.0006). No significant correlation was found between ADC mean and SUV mean (r = -0.42; P = 0.1392). Also, SUV max from the PET/CT data showed significant reverse correlation to ADC min (r = -0.62; P = 0.019). The voxelwise analysis of 5 pulmonary lesions each showed weak but significant negative correlation between ADC and SUV. Examinations of pulmonary lesions in a simultaneous whole-body MR/PET system provide diagnostic image quality in both modalities. Although DWI and FDG-PET reflect different tissue properties, there may very well be an association between the measures of both methods most probably because of increased cellularity and glucose metabolism of FDG-avid pulmonary lesions. A voxelwise DWI and FDG-PET correlation might provide a more sophisticated spatial characterization of pulmonary lesions.

  20. Clinical and computed tomography features of adult abdominopelvic desmoplastic small round cell tumor.

    PubMed

    Shen, Xun-Ze; Zhao, Jian-Guo; Wu, Jian-Jun; Liu, Fang

    2014-05-07

    To investigate the clinical and computed tomography (CT) features of desmoplastic small round cell tumor (DSRCT), we retrospectively analyzed the clinical presentations, treatment and outcome, as well as CT manifestations of four cases of DSRCT confirmed by surgery and pathology. The CT manifestations of DSRCT were as follows: (1) multiple soft-tissue masses or diffuse peritoneal thickening in the abdomen and pelvis, with the dominant mass usually located in the pelvic cavity; (2) masses without an apparent organ-based primary site; (3) mild to moderate homogeneous or heterogeneous enhancement in solid area on enhanced CT; and (4) secondary manifestations, such as ascites, hepatic metastases, lymphadenopathy, hydronephrosis and hydroureter. The prognosis and overall survival rates were generally poor. Commonly used treatment strategies including aggressive tumor resection, polychemotherapy, and radiotherapy, showed various therapeutic effects. CT of DSRCT shows characteristic features that are helpful in diagnosis. Early discovery and complete resection, coupled with postoperative adjuvant chemotherapy, are important for prognosis of DSRCT. Whole abdominopelvic rather than locoregional radiotherapy is more effective for unresectable DSRCT.

  1. Cerebral blood flow during paroxysmal EEG activation induced by sleep in patients with complex partial seizures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gozukirmizi, E.; Meyer, J.S.; Okabe, T.

    1982-01-01

    Cerebral blood flow (CBF) measurements were combined with sleep polysomnography in nine patients with complex partial seizures. Two methods were used: the 133Xe method for measuring regional (rCBF) and the stable xenon CT method for local (LCBF). Compared to nonepileptic subjects, who show diffuse CBF decreases during stages I-II, non-REM sleep onset, patients with complex partial seizures show statistically significant increases in CBF which are maximal in regions where the EEG focus is localized and are predominantly seen in one temporal region but are also propagated to other cerebral areas. Both CBF methods gave comparable results, but greater statistical significancemore » was achieved by stable xenon CT methodology. CBF increases are more diffuse than predicted by EEG paroxysmal activity recorded from scalp electrodes. An advantage of the 133Xe inhalation method was achievement of reliable data despite movement of the head. This was attributed to the use of a helmet which maintained the probes approximated to the scalp. Disadvantages were poor resolution (7 cm3) and two-dimensional information. The advantage of stable xenon CT method is excellent resolution (80 mm3) in three dimensions, but a disadvantage is that movement of the head in patients with seizure disorders may limit satisfactory measurements.« less

  2. WE-AB-204-07: Spatiotemporal Distribution of the FDG PET Tracer in Solid Tumors: Contributions of Diffusion and Convection Mechanisms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soltani, M; Sefidgar, M; Bazmara, H

    2015-06-15

    Purpose: In this study, a mathematical model is utilized to simulate FDG distribution in tumor tissue. In contrast to conventional compartmental modeling, tracer distributions across space and time are directly linked together (i.e. moving beyond ordinary differential equations (ODEs) to utilizing partial differential equations (PDEs) coupling space and time). The diffusion and convection transport mechanisms are both incorporated to model tracer distribution. We aimed to investigate the contributions of these two mechanisms on FDG distribution for various tumor geometries obtained from PET/CT images. Methods: FDG transport was simulated via a spatiotemporal distribution model (SDM). The model is based on amore » 5K compartmental model. We model the fact that tracer concentration in the second compartment (extracellular space) is modulated via convection and diffusion. Data from n=45 patients with pancreatic tumors as imaged using clinical FDG PET/CT imaging were analyzed, and geometrical information from the tumors including size, shape, and aspect ratios were classified. Tumors with varying shapes and sizes were assessed in order to investigate the effects of convection and diffusion mechanisms on FDG transport. Numerical methods simulating interstitial flow and solute transport in tissue were utilized. Results: We have shown the convection mechanism to depend on the shape and size of tumors whereas diffusion mechanism is seen to exhibit low dependency on shape and size. Results show that concentration distribution of FDG is relatively similar for the considered tumors; and that the diffusion mechanism of FDG transport significantly dominates the convection mechanism. The Peclet number which shows the ratio of convection to diffusion rates was shown to be of the order of 10−{sup 3} for all considered tumors. Conclusion: We have demonstrated that even though convection leads to varying tracer distribution profiles depending on tumor shape and size, the domination of the diffusion phenomenon prevents these factors from modulating FDG distribution.« less

  3. Thermal conditions influence changes in body temperature induced by intragastric administration of capsaicin in mice.

    PubMed

    Mori, Noriyuki; Urata, Tomomi; Fukuwatari, Tsutomu

    2016-08-01

    Capsaicin has been reported to have unique thermoregulatory actions. However, changes in core temperature after the administration of capsaicin are a controversial point. Therefore, we investigated the effects of environmental thermal conditions on changes in body temperature caused by capsaicin in mice. We showed that intragastric administration of 10 and 15 mg/kg capsaicin increased tail temperature and decreased colonic temperatures in the core temperature (CT)-constant and CT-decreasing conditions. In the CT-increasing condition, 15 mg/kg capsaicin increased tail temperature and decreased colonic temperature. However, 10 mg/kg capsaicin increased colonic temperature. Furthermore, the amount of increase in tail temperature was greater in the CT-decreasing condition and lower in the CT-increasing condition, compared with that of the CT-constant condition. These findings suggest that the changes in core temperature were affected by the environmental thermal conditions and that preliminary thermoregulation state might be more important than the constancy of temperature to evaluate the effects of heat diffusion and thermogensis.

  4. Improved knowledge diffusion model based on the collaboration hypernetwork

    NASA Astrophysics Data System (ADS)

    Wang, Jiang-Pan; Guo, Qiang; Yang, Guang-Yong; Liu, Jian-Guo

    2015-06-01

    The process for absorbing knowledge becomes an essential element for innovation in firms and in adapting to changes in the competitive environment. In this paper, we present an improved knowledge diffusion hypernetwork (IKDH) model based on the idea that knowledge will spread from the target node to all its neighbors in terms of the hyperedge and knowledge stock. We apply the average knowledge stock V(t) , the variable σ2(t) , and the variance coefficient c(t) to evaluate the performance of knowledge diffusion. By analyzing different knowledge diffusion ways, selection ways of the highly knowledgeable nodes, hypernetwork sizes and hypernetwork structures for the performance of knowledge diffusion, results show that the diffusion speed of IKDH model is 3.64 times faster than that of traditional knowledge diffusion (TKDH) model. Besides, it is three times faster to diffuse knowledge by randomly selecting "expert" nodes than that by selecting large-hyperdegree nodes as "expert" nodes. Furthermore, either the closer network structure or smaller network size results in the faster knowledge diffusion.

  5. Vessel Enhancement and Segmentation of 4D CT Lung Image Using Stick Tensor Voting

    NASA Astrophysics Data System (ADS)

    Cong, Tan; Hao, Yang; Jingli, Shi; Xuan, Yang

    2016-12-01

    Vessel enhancement and segmentation plays a significant role in medical image analysis. This paper proposes a novel vessel enhancement and segmentation method for 4D CT lung image using stick tensor voting algorithm, which focuses on addressing the vessel distortion issue of vessel enhancement diffusion (VED) method. Furthermore, the enhanced results are easily segmented using level-set segmentation. In our method, firstly, vessels are filtered using Frangi's filter to reduce intrapulmonary noises and extract rough blood vessels. Secondly, stick tensor voting algorithm is employed to estimate the correct direction along the vessel. Then the estimated direction along the vessel is used as the anisotropic diffusion direction of vessel in VED algorithm, which makes the intensity diffusion of points locating at the vessel wall be consistent with the directions of vessels and enhance the tubular features of vessels. Finally, vessels can be extracted from the enhanced image by applying level-set segmentation method. A number of experiments results show that our method outperforms traditional VED method in vessel enhancement and results in satisfied segmented vessels.

  6. F-18 FDG PET/CT findings of a case of sacral nerve root neurolymphomatosis that occurred during chemotherapy.

    PubMed

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Matsunaga, Naofumi; Yujiri, Toshiaki; Nakazora, Tatsuki; Ariyoshi, Kouichi

    2011-01-01

    Neurolymphomatosis (NL) is a rare, unique subtype of lymphomatous infiltration of peripheral nerves. Clinical/radiologic diagnosis of NL is challenging. We report F-18 FDG PET/CT findings of a case of breast diffuse large B-cell lymphoma, in which NL developed regardless of regression of systemic lesions during induction chemotherapy. FDG PET/CT showed characteristic findings of well-demarcated, linear abnormal FDG uptake along a sacral vertebral foramen, leading to diagnosis of NL, with the finding of thickened nerve roots on magnetic resonance imaging. Altered chemotherapeutic regimen resulted in disappearance of these abnormal FDG uptake, with recovery of neurologic symptoms. Peripheral nerve NL may occur during chemotherapy, and FDG PET/CT can be a useful imaging modality in diagnosis and monitoring of therapeutic response of this disease.

  7. PET/CT incidental detection of second tumor in patients investigated for pancreatic neoplasms.

    PubMed

    Moletta, Lucia; Bissoli, Sergio; Fantin, Alberto; Passuello, Nicola; Valmasoni, Michele; Sperti, Cosimo

    2018-05-04

    Positron Emission Tomography/computed tomography (PET/CT) is an imaging technique which has a role in the detection and staging malignancies (both in first diagnosis and follow-up). The finding of an unexpected region of FDG (Fluorodeoxyglucose) uptake can occur when performing whole-body FDG-PET, raising the possibility of a second primary tumor. The aim of this study was to evaluate our experience of second primary cancer incidentally discovered during PET/CT examination performed for pancreatic diseases, during the initial work-up or follow-up after surgical resection. In this study, a retrospective evaluation of a prospectively collected data base was performed. Three hundred ninety- nine patients with pancreatic pathology were evaluated by whole body PET/CT imaging from January 2004 to December 2014. Among them, 348 patients were scanned before surgical resection and 51 during the course of their follow-up (pancreatic cancer). Median follow-up time was 29 months (range 14-124). Fifty-six patients (14%) had incidental uptake of FDG in their organs: 31 patients had focal uptake and 25 showed diffuse with or without focal uptake. All patients with focal uptake were investigated, and invasive malignancy was diagnosed in 22 patients: 14 colon, 4 lung, 1 larynx, 1 urothelial, 1 breast cancer, and 1 colon metastasis from pancreatic cancer. Twenty patients underwent resection, and 6 endoscopic removal of colonic polyps. Three patients were not operated for advanced disease, and two patients did not show any pathology (PET/CT false positive). Of the 10 patients investigated for diffuse uptake, no malignancy was found; none of these patients developed a second cancer during the follow-up. As in other malignancies, unexpected FDG uptake can occur in patients having PET/CT investigation for pancreatic diseases. Focal uptake is likely to be a malignancy and deserves further investigations, although the stage and the poor prognosis of primary pancreatic cancer should be kept in mind. Some selected patients may benefit from the aggressive treatment of incidental lesions and show survival benefit.

  8. CT and MRI Findings in Cerebral Aspergilloma.

    PubMed

    Gärtner, Friederike; Forstenpointner, Julia; Ertl-Wagner, Birgit; Hooshmand, Babak; Riedel, Christian; Jansen, Olav

    2017-11-20

    Purpose  Invasive aspergillosis usually affects immunocompromised patients. It carries a high risk of morbidity and mortality and usually has a nonspecific clinical presentation. Early diagnosis is essential in order to start effective treatment and improve clinical outcome. Materials and Methods  In a retrospective search of the PACS databases from two medical centers, we identified 9 patients with histologically proven cerebral aspergilloma. We systematically analyzed CT and MRI imaging findings to identify typical imaging appearances of cerebral aspergilloma. Results  CT did not show a typical appearance of the aspergillomas. In 100 % (9/9) there was a rim-attenuated diffusion restriction on MRI imaging. Multiple hypointense layers in the aspergillus wall, especially on the internal side, were detected in 100 % on T2-weighted imaging (9/9). Aspergillomas were T1-hypointense in 66 % of cases (6/9) and partly T1-hyperintense in 33 % (3/9). In 78 % (7/9) of cases, a rim-attenuated diffusion restriction was detected after contrast agent application. Conclusion  Nine cases were identified. Whereas CT features were less typical, we observed the following imaging features on MRI: A strong, rim-attenuated diffusion restriction (9/9); onion layer-like hypointense zones, in particular in the innermost part of the abscess wall on T2-weighted images (9/9). Enhancement of the lesion border was present in the majority of the cases (7/9). Key points   · There are typical MRI imaging features of aspergillomas.. · However, these findings could be affected by the immune status of the patient.. · Swift identification of aspergilloma imaging patterns is essential to allow for adequate therapeutic decision making.. Citation Format · Gärtner F, Forstenpointner J, Ertl-Wagner B et al. CT and MRI Findings in Cerebral Aspergilloma. Fortschr Röntgenstr 2017; DOI: 10.1055/s-0043-120766. © Georg Thieme Verlag KG Stuttgart · New York.

  9. [The application of multi-slice CT dynamic enhancement scan in the diagnosis and treatment of colonic lymphomas].

    PubMed

    Wang, Xi-ming; Wu, Le-bin; Zhang, Yun-ting; Li, Zhen-jia; Liu, Chen

    2006-11-01

    To discuss the value of multi-slice CT dynamic enhancement scan in the diagnosis and treatment of colonic lymphomas. 16 patients with colonic lymphomas underwent multi-slice CT dynamic enhancement scans, images of axial and reconstructive images of VR, MPR and CTVE were analyzed, patients were respectively diagnosed. Appearances of primary colorectal lymphomas were categorized into focal and diffuse lesions. Focal and diffuse lesions were 6 and 10 patients, respectively. The accuracy rate of diagnosis was 87.5%. MSCT dynamic scan has distinctive superiority in diagnosis and treatment of colonic lymphomas.

  10. Fusion of MRIs and CT scans for surgical treatment of cholesteatoma of the middle ear in children.

    PubMed

    Plouin-Gaudon, Isabelle; Bossard, Denis; Ayari-Khalfallah, Sonia; Froehlich, Patrick

    2010-09-01

    To evaluate the efficiency of diffusion-weighted magnetic resonance imaging (MRI) and high-resolution computed tomographic (CT) scan coregistration in predicting and adequately locating primary or recurrent cholesteatoma in children. Prospective study. Tertiary care university hospital. Ten patients aged 2 to 17 years (mean age, 8.5 years) with cholesteatoma of the middle ear, some of which were previously treated, were included for follow-up with systematic CT scanning and MRI between 2007 and 2008. Computed tomographic scanning was performed on a Siemens Somaton 128 (0.5/0.2-mm slices reformatted in 0.5/0.3-mm images). Fine cuts were obtained parallel and perpendicular to the lateral semicircular canal in each ear (100 × 100-mm field of view). Magnetic resonance imaging was undertaken on a Siemens Avanto 1.5T unit, with a protocol adapted for young children. Diffusion-weighted imaging was acquired using a single-shot turbo spin-echo mode. To allow for diagnosis and localization of the cholesteatoma, CT and diffusion-weighted MRIs were fused for each case. In 10 children, fusion technique allowed for correct diagnosis and precise localization (hypotympanum, epitympanum, mastoid recess, and attical space) as confirmed by subsequent standard surgery (positive predictive value, 100%). In 3 cases, the surgical approach was adequately determined from the fusion results. Lesion sizes on the CT-MRI fusion corresponded with perioperative findings. Recent developments in imaging techniques have made diffusion-weighted MRI more effective for detecting recurrent cholesteatoma. The major drawback of this technique, however, has been its poor anatomical and spatial discrimination. Fusion imaging using high-resolution CT and diffusion-weighted MRI appears to be a promising technique for both the diagnosis and precise localization of cholesteatomas. It provides useful information for surgical planning and, furthermore, is easy to use in pediatric cases.

  11. Spectral Diffusion: An Algorithm for Robust Material Decomposition of Spectral CT Data

    PubMed Central

    Clark, Darin P.; Badea, Cristian T.

    2014-01-01

    Clinical successes with dual energy CT, aggressive development of energy discriminating x-ray detectors, and novel, target-specific, nanoparticle contrast agents promise to establish spectral CT as a powerful functional imaging modality. Common to all of these applications is the need for a material decomposition algorithm which is robust in the presence of noise. Here, we develop such an algorithm which uses spectrally joint, piece-wise constant kernel regression and the split Bregman method to iteratively solve for a material decomposition which is gradient sparse, quantitatively accurate, and minimally biased. We call this algorithm spectral diffusion because it integrates structural information from multiple spectral channels and their corresponding material decompositions within the framework of diffusion-like denoising algorithms (e.g. anisotropic diffusion, total variation, bilateral filtration). Using a 3D, digital bar phantom and a material sensitivity matrix calibrated for use with a polychromatic x-ray source, we quantify the limits of detectability (CNR = 5) afforded by spectral diffusion in the triple-energy material decomposition of iodine (3.1 mg/mL), gold (0.9 mg/mL), and gadolinium (2.9 mg/mL) concentrations. We then apply spectral diffusion to the in vivo separation of these three materials in the mouse kidneys, liver, and spleen. PMID:25296173

  12. Spectral diffusion: an algorithm for robust material decomposition of spectral CT data.

    PubMed

    Clark, Darin P; Badea, Cristian T

    2014-11-07

    Clinical successes with dual energy CT, aggressive development of energy discriminating x-ray detectors, and novel, target-specific, nanoparticle contrast agents promise to establish spectral CT as a powerful functional imaging modality. Common to all of these applications is the need for a material decomposition algorithm which is robust in the presence of noise. Here, we develop such an algorithm which uses spectrally joint, piecewise constant kernel regression and the split Bregman method to iteratively solve for a material decomposition which is gradient sparse, quantitatively accurate, and minimally biased. We call this algorithm spectral diffusion because it integrates structural information from multiple spectral channels and their corresponding material decompositions within the framework of diffusion-like denoising algorithms (e.g. anisotropic diffusion, total variation, bilateral filtration). Using a 3D, digital bar phantom and a material sensitivity matrix calibrated for use with a polychromatic x-ray source, we quantify the limits of detectability (CNR = 5) afforded by spectral diffusion in the triple-energy material decomposition of iodine (3.1 mg mL(-1)), gold (0.9 mg mL(-1)), and gadolinium (2.9 mg mL(-1)) concentrations. We then apply spectral diffusion to the in vivo separation of these three materials in the mouse kidneys, liver, and spleen.

  13. Renal carcinomas associated with Xp11.2 translocations: are CT findings suggestive of the diagnosis?

    PubMed

    He, J; Huan, Y; Qiao, Q; Zhang, J; Zhang, J S

    2014-01-01

    The purpose of the present study was to summarize the computed tomography (CT) features of renal carcinomas associated with Xp11.2 translocations, and determine whether the diagnosis can be reliably deduced from imaging findings. Radiological studies of six patients (aged from 9-29 years) with renal carcinoma associated with Xp11.2 translocations were retrospectively analysed. The tumours varied in size from 3.3-11 cm (mean 5.4 cm). Unenhanced CT and cortical, medullary, and pelvic-phase contrast-enhanced CT imaging was undertaken in all cases. Unenhanced CT revealed that tumours had a relatively increased radiodensity (4/6, ranged from 45-60 HU) and suggested the possibility of diffuse haemorrhage. Three of the six cases showed irregular and boundary calcification of the lesion. Contrast-enhanced CT showed relatively well demarcated tumours with heterogeneous enhancement (6/6). Prolonged enhancement of tumours might be a common sign (6/6) in Xp11.2 translocations. Three out of the six cases were combined with retroperitoneal lymph nodes metastasis. Renal carcinomas associated with Xp11.2 translocations should be considered, particularly in children and young patients, when the lesion has calcification and is hyper-dense on unenhanced CT, and has prolonged enhancement on contrast-enhanced images. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. Charge transfer fluorescence and 34 nm exciton diffusion length in polymers with electron acceptor end traps

    DOE PAGES

    Zaikowski, Lori; Mauro, Gina; Bird, Matthew; ...

    2014-12-22

    Photoexcitation of conjugated poly-2,7-(9,9-dihexylfluorene) polyfluorenes with naphthylimide (NI) and anthraquinone (AQ) electron-acceptor end traps produces excitons that form charge transfer states at the end traps. Intramolecular singlet exciton transport to end traps was examined by steady state fluorescence for polyfluorenes of 17 to 127 repeat units in chloroform, dimethylformamide (DMF), tetrahydrofuran (THF), and p-xylene. End traps capture excitons and form charge transfer (CT) states at all polymer lengths and in all solvents. The CT nature of the end-trapped states is confirmed by their fluorescence spectra, solvent and trap group dependence and DFT descriptions. Quantum yields of CT fluorescence are asmore » large as 46%. This strong CT emission is understood in terms of intensity borrowing. Energies of the CT states from onsets of the fluorescence spectra give the depths of the traps which vary with solvent polarity. For NI end traps the trap depths are 0.06 (p-xylene), 0.13 (THF) and 0.19 eV (CHCl 3). For AQ, CT fluorescence could be observed only in p-xylene where the trap depth is 0.27 eV. Quantum yields, emission energies, charge transfer energies, solvent reorganization and vibrational energies were calculated. Fluorescence measurements on chains >100 repeat units indicate that end traps capture ~50% of the excitons, and that the exciton diffusion length L D =34 nm, which is much larger than diffusion lengths reported in polymer films or than previously known for diffusion along isolated chains. As a result, the efficiency of exciton capture depends on chain length, but not on trap depth, solvent polarity or which trap group is present.« less

  15. Different predictive values of interim 18F-FDG PET/CT in germinal center like and non-germinal center like diffuse large B-cell lymphoma.

    PubMed

    Kim, Jihyun; Lee, Jeong-Ok; Paik, Jin Ho; Lee, Won Woo; Kim, Sang Eun; Song, Yoo Sung

    2017-01-01

    Diffuse large B-cell lymphoma (DLBCL) is a pathologically heterogeneous disease with different prognoses according to its molecular profiles. Despite the broad usage of 18 F-fluoro-2-dexoxy-D-glucose (FDG) positron emission tomography/computed tomography (PET/CT), previous studies that have investigated the value of interim 18 F-FDG PET/CT in DLBCL have given the controversial results. The purpose of this study was to evaluate the prognostic value of interim 18 F-FDG PET/CT in DLBCL according to germinal center B cell-like (GCB) and non-GCB molecular profiling. We enrolled 118 newly diagnosed DLBCL patients treated with rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisolone (R-CHOP). Interim 18 F-FDG PET/CT scans performed after 2 or 3 cycles of R-CHOP treatment were evaluated based on the Lugano response criteria. Patients were grouped as GCB or non-GCB molecular subtypes according to immunohistochemistry results of CD10, BCL6, and MUM1, based on Hans' algorithm. In total 118 DLBCL patients, 35 % were classified as GCB, and 65 % were classified as non-GCB. Interim PET/CT was negative in 70 %, and positive in 30 %. During the median follow-up period of 23 months, the positive interim 18 F-FDG PET/CT group showed significantly inferior progression free survival (PFS) compared to the negative interim 18 F-FDG PET/CT group (P = 0.0004) in entire patients. A subgroup analysis according to molecular profiling demonstrated significant difference of PFS between the positive and negative interim 18 F-FDG PET groups in GCB subtype of DLBCL (P = 0.0001), but there was no significant difference of PFS between the positive and negative interim 18 F-FDG PET groups in non-GCB subtype of DLBCL. Interim 18 F-FDG PET/CT scanning had a significant predictive value for disease progression in patients with the GCB subtype of DLBCL treated with R-CHOP, but not in those with the non-GCB subtype. Therefore, molecular profiles of DLBCL should be considered for interim 18 F-FDG PET/CT practice.

  16. Types of traumatic brain injury and regional cerebral blood flow assessed by 99mTc-HMPAO SPECT.

    PubMed

    Yamakami, I; Yamaura, A; Isobe, K

    1993-01-01

    To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with 99mtechnetium-hexamethyl propyleneamine oxime. Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated 1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, 2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and 3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient.

  17. Nonlinear histogram binning for quantitative analysis of lung tissue fibrosis in high-resolution CT data

    NASA Astrophysics Data System (ADS)

    Zavaletta, Vanessa A.; Bartholmai, Brian J.; Robb, Richard A.

    2007-03-01

    Diffuse lung diseases, such as idiopathic pulmonary fibrosis (IPF), can be characterized and quantified by analysis of volumetric high resolution CT scans of the lungs. These data sets typically have dimensions of 512 x 512 x 400. It is too subjective and labor intensive for a radiologist to analyze each slice and quantify regional abnormalities manually. Thus, computer aided techniques are necessary, particularly texture analysis techniques which classify various lung tissue types. Second and higher order statistics which relate the spatial variation of the intensity values are good discriminatory features for various textures. The intensity values in lung CT scans range between [-1024, 1024]. Calculation of second order statistics on this range is too computationally intensive so the data is typically binned between 16 or 32 gray levels. There are more effective ways of binning the gray level range to improve classification. An optimal and very efficient way to nonlinearly bin the histogram is to use a dynamic programming algorithm. The objective of this paper is to show that nonlinear binning using dynamic programming is computationally efficient and improves the discriminatory power of the second and higher order statistics for more accurate quantification of diffuse lung disease.

  18. Diffuse Large B-Cell Lymphoma: Prospective Multicenter Comparison of Early Interim FLT PET/CT versus FDG PET/CT with IHP, EORTC, Deauville, and PERCIST Criteria for Early Therapeutic Monitoring

    PubMed Central

    Minamimoto, Ryogo; Fayad, Luis; Advani, Ranjana; Vose, Julie; Macapinlac, Homer; Meza, Jane; Hankins, Jordan; Mottaghy, Felix; Juweid, Malik

    2016-01-01

    Purpose To compare the performance characteristics of interim fluorine 18 (18F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) (after two cycles of chemotherapy) by using the most prominent standardized interpretive criteria (including International Harmonization Project [IHP] criteria, European Organization for Research and Treatment of Cancer [EORTC] criteria, and PET Response Criteria in Solid Tumors (PERCIST) versus those of interim 18F fluorothymidine (FLT) PET/CT and simple visual interpretation. Materials and Methods This HIPAA-compliant prospective study was approved by the institutional review boards, and written informed consent was obtained. Patients with newly diagnosed diffuse large B-cell lymphoma (DLBCL) underwent both FLT and FDG PET/CT 18–24 days after two cycles of rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone or rituximab, etoposide, prednisone, vincristine, cyclophosphamide, and doxorubicin. For FDG PET/CT interpretation, IHP criteria, EORTC criteria, PERCIST, Deauville criteria, standardized uptake value, total lesion glycolysis, and metabolic tumor volume were used. FLT PET/CT images were interpreted with visual assessment by two reviewers in consensus. The interim (after cycle 2) FDG and FLT PET/CT studies were then compared with the end-of-treatment FDG PET/CT studies to determine which interim examination and/or criteria best predicted the result after six cycles of chemotherapy. Results From November 2011 to May 2014, there were 60 potential patients for inclusion, of whom 46 patients (24 men [mean age, 60.9 years ± 13.7; range, 28–78 years] and 22 women [mean age, 57.2 years ± 13.4; range, 25–76 years]) fulfilled the criteria. Thirty-four patients had complete response, and 12 had residual disease at the end of treatment. FLT PET/CT had a significantly higher positive predictive value (PPV) (91%) in predicting residual disease than did any FDG PET/CT interpretation method (42%–46%). No difference in negative predictive value (NPV) was found between FLT PET/CT (94%) and FDG PET/CT (82%–95%), regardless of the interpretive criteria used. FLT PET/CT showed statistically higher (P < .001–.008) or similar NPVs than did FDG PET/CT. Conclusion Early interim FLT PET/CT had a significantly higher PPV than standardized FDG PET/CT–based interpretation for therapeutic response assessment in DLBCL. © RSNA, 2016 Online supplemental material is available for this article. PMID:26854705

  19. Micro-CT X-ray imaging exposes structured diffusion barriers within biofilms.

    PubMed

    Keren-Paz, Alona; Brumfeld, Vlad; Oppenheimer-Shaanan, Yaara; Kolodkin-Gal, Ilana

    2018-01-01

    In nature, bacteria predominantly exist as highly structured biofilms, which are held together by extracellular polymeric substance and protect their residents from environmental insults, such as antibiotics. The mechanisms supporting this phenotypic resistance are poorly understood. Recently, we identified a new mechanism maintaining biofilms - an active production of calcite minerals. In this work, a high-resolution and robust µCT technique is used to study the mineralized areas within intact bacterial biofilms. µCT is a vital tool for visualizing bacterial communities that can provide insights into the relationship between bacterial biofilm structure and function. Our results imply that dense and structured calcium carbonate lamina forms a diffusion barrier sheltering the inner cell mass of the biofilm colony. Therefore, µCT can be employed in clinical settings to predict the permeability of the biofilms. It is demonstrated that chemical interference with urease, a key enzyme in biomineralization, inhibits the assembly of complex bacterial structures, prevents the formation of mineral diffusion barriers and increases biofilm permeability. Therefore, biomineralization enzymes emerge as novel therapeutic targets for highly resistant infections.

  20. Bilateral symmetrical adrenal hypermetabolism on FDG PET/CT due to Cushing syndrome in well differentiated neuroendocrine carcinoma.

    PubMed

    Aktas, G E; Soyluoglu Demir, S; Sarikaya, A

    2016-01-01

    The (18)F-FDG PET/CT scan has been suggested for whole-body imaging to identify ectopic adrenocorticotrophic hormone secreting tumours, but there are some challenges involved. The case of a patient is presented, who was admitted with the pre-diagnosis of ectopic ACTH syndrome. On the CT, a nodular lesion was detected in the medial segment of the right lung. The FDG uptake of the lesion seemed to be increased visually, but was not pathological quantitatively (SUVmax: 1.8) on the PET/CT. There was also diffuse increased uptake (SUVmax: 14.2) in the enlarged adrenal glands. The lesion was reported as a possible malignant lesion with low FDG affinity, such as a low grade neuroendocrine tumour, while the diffuse enlarged adrenal glands with high uptake were interpreted as diffusely hyperplasic, due to Cushing's syndrome. The patient was treated with a surgical wedge resection. The histopathological diagnosis confirmed that the tumour was a grade 1 well-differentiated neuroendocrine carcinoma. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  1. ‘Double cortex’ sign on FDG-PET/CT in diffuse band heterotopia

    PubMed Central

    Tripathi, Madhavi; Tripathi, Manjari; Kumar, Ganesh; Malhotra, Arun; Bal, Chandra Sekhar

    2013-01-01

    F-18 Fluorodeoxyglucose (FDG) Positron emission tomography/Computed Tomography (PET/CT) has come to play an increasingly important role for the pre-surgical evaluation of drug resistant epilepsy and complements Magnetic Resonance Imaging (MRI) in the evaluation of grey matter heterotopias. This case illustrates the characteristic pattern of metabolic abnormality in diffuse band heterotopia (DBH) which is otherwise called double cortex syndrome. The presence of metabolic activity in the heterotopic inner cortical band and in the overlying true cortex gives rise to the ‘double cortex’ sign on FDG-PET, concurrent CT provides a good anato-metabolic coregistration. PMID:24379541

  2. CCR investigators use liquid biopsies to uncover cancer in the blood of lymphoma patients | Center for Cancer Research

    Cancer.gov

    CCR investigators are using circulating tumor DNA (ctDNA) as a type of noninvasive liquid biopsy for patients with diffuse large B-cell lymphoma (DLBCL), the most common type of non-Hodgkin lymphoma. are using circulating tumor DNA (ctDNA) as a type of noninvasive liquid biopsy for patients with diffuse large B-cell lymphoma (DLBCL), the most common type of non-Hodgkin lymphoma.

  3. CCR investigators use liquid biopsies to uncover cancer in the blood of lymphoma patients | Center for Cancer Research

    Cancer.gov

    CCR investigators are using circulating tumor DNA (ctDNA) as a type of noninvasive liquid biopsy for patients with diffuse large B-cell lymphoma (DLBCL), the most common type of non-Hodgkin lymphoma. are using circulating tumor DNA (ctDNA) as a type of noninvasive liquid biopsy for patients with diffuse large B-cell lymphoma (DLBCL), the most common type of non-Hodgkin

  4. Idiopathic Pulmonary Fibrosis: Data-driven Textural Analysis of Extent of Fibrosis at Baseline and 15-Month Follow-up.

    PubMed

    Humphries, Stephen M; Yagihashi, Kunihiro; Huckleberry, Jason; Rho, Byung-Hak; Schroeder, Joyce D; Strand, Matthew; Schwarz, Marvin I; Flaherty, Kevin R; Kazerooni, Ella A; van Beek, Edwin J R; Lynch, David A

    2017-10-01

    Purpose To evaluate associations between pulmonary function and both quantitative analysis and visual assessment of thin-section computed tomography (CT) images at baseline and at 15-month follow-up in subjects with idiopathic pulmonary fibrosis (IPF). Materials and Methods This retrospective analysis of preexisting anonymized data, collected prospectively between 2007 and 2013 in a HIPAA-compliant study, was exempt from additional institutional review board approval. The extent of lung fibrosis at baseline inspiratory chest CT in 280 subjects enrolled in the IPF Network was evaluated. Visual analysis was performed by using a semiquantitative scoring system. Computer-based quantitative analysis included CT histogram-based measurements and a data-driven textural analysis (DTA). Follow-up CT images in 72 of these subjects were also analyzed. Univariate comparisons were performed by using Spearman rank correlation. Multivariate and longitudinal analyses were performed by using a linear mixed model approach, in which models were compared by using asymptotic χ 2 tests. Results At baseline, all CT-derived measures showed moderate significant correlation (P < .001) with pulmonary function. At follow-up CT, changes in DTA scores showed significant correlation with changes in both forced vital capacity percentage predicted (ρ = -0.41, P < .001) and diffusing capacity for carbon monoxide percentage predicted (ρ = -0.40, P < .001). Asymptotic χ 2 tests showed that inclusion of DTA score significantly improved fit of both baseline and longitudinal linear mixed models in the prediction of pulmonary function (P < .001 for both). Conclusion When compared with semiquantitative visual assessment and CT histogram-based measurements, DTA score provides additional information that can be used to predict diminished function. Automatic quantification of lung fibrosis at CT yields an index of severity that correlates with visual assessment and functional change in subjects with IPF. © RSNA, 2017.

  5. Contribution of CT quantified emphysema, air trapping and airway wall thickness on pulmonary function in male smokers with and without COPD.

    PubMed

    Mohamed Hoesein, Firdaus A A; de Jong, Pim A; Lammers, Jan-Willem J; Mali, Willem P Th M; Mets, Onno M; Schmidt, Michael; de Koning, Harry J; Aalst, Carlijn van der; Oudkerk, Matthijs; Vliegenthart, Rozemarijn; Ginneken, Bram van; van Rikxoort, Eva M; Zanen, Pieter

    2014-09-01

    Emphysema, airway wall thickening and air trapping are associated with chronic obstructive pulmonary disease (COPD). All three can be quantified by computed tomography (CT) of the chest. The goal of the current study is to determine the relative contribution of CT derived parameters on spirometry, lung volume and lung diffusion testing. Emphysema, airway wall thickening and air trapping were quantified automatically on CT in 1,138 male smokers with and without COPD. Emphysema was quantified by the percentage of voxels below -950 Hounsfield Units (HU), airway wall thickness by the square root of wall area for a theoretical airway with 10 mm lumen perimeter (Pi10) and air trapping by the ratio of mean lung density at expiration and inspiration (E/I-ratio). Spirometry, residual volume to total lung capacity (RV/TLC) and diffusion capacity (Kco) were obtained. Standardized regression coefficients (β) were used to analyze the relative contribution of CT changes to pulmonary function measures. The independent contribution of the three CT measures differed per lung function parameter. For the FEV1 airway wall thickness was the most contributing structural lung change (β = -0.46), while for the FEV1/FVC this was emphysema (β = -0.55). For the residual volume (RV) air trapping was most contributing (β = -0.35). Lung diffusion capacity was most influenced by emphysema (β = -0.42). In a cohort of smokers with and without COPD the effect of different CT changes varies per lung function measure and therefore emphysema, airway wall thickness and air trapping need to be taken in account.

  6. Autoimmune pancreatitis: CT patterns and their changes after steroid treatment.

    PubMed

    Manfredi, Riccardo; Graziani, Rossella; Cicero, Calogero; Frulloni, Luca; Carbognin, Giovanni; Mantovani, William; Mucelli, Roberto Pozzi

    2008-05-01

    To retrospectively evaluate the computed tomographic (CT) patterns of autoimmune pancreatitis (AIP) and their changes after steroid therapy. Investigational review board approval was obtained, and the informed consent requirement was waived. The medical and imaging data of 21 patients (13 men, eight women; mean age, 47.5 years; age range, 25-79 years) with histopathologically proved AIP who underwent contrast material-enhanced CT at diagnosis and after steroid treatment were included in this study. Image analysis included assessment of the (a) presence or absence and type (focal or diffuse) of pancreatic parenchyma enlargement, (b) contrast enhancement of pancreatic parenchyma, (c) size of the main pancreatic duct (MPD) within the lesion and upstream, and (d) pancreatic parenchyma thickness in the head, body, and tail of the pancreas. The same criteria were applied to follow-up CT examinations, the follow-up data were compared with pretreatment data, and a paired sample t test was applied. Pancreatic parenchyma showed focal enlargement in 14 (67%) patients and diffuse enlargement in seven (33%). Pancreatic parenchyma affected by AIP appeared hypoattenuating in 19 (90%) patients and isoattenuating in two (10%). During the portal venous phase, pancreatic parenchyma showed contrast material retention in 18 (86%) patients and contrast material washout in three (14%). The MPD was never visible within the lesion. After treatment, there was a reduction in the size of pancreatic parenchyma segments affected by AIP (P < .05). Fifteen (71%) of the 21 patients had a normal enhancement pattern in the pancreatic parenchyma, whereas the enhancement pattern remained hypovascular in six (29%). The MPD returned to its normal size within the lesion in all patients at follow-up CT. In one of the eight patients with focal forms of AIP, the upstream MPD remained dilated. AIP appeared as pancreatic parenchyma enlargement, with MPD stenosis within the lesion and upstream dilatation in focal forms of AIP. After steroid treatment, there was normalization of these findings. (c) RSNA, 2008.

  7. De novo CD5-positive primary cardiac diffuse large B-cell lymphoma diagnosed by pleural fluid cytology.

    PubMed

    Cioc, Adina M; Jessurun, José; Vercellotti, Gregory M; Pambuccian, Stefan E

    2014-03-01

    Primary cardiac lymphomas are exceedingly rare. The presence and extent of the intracardiac mass is determined by echocardiography, computed tomography (CT), or magnetic resonance imaging (MRI); however, the diagnosis is established by endomyocardial biopsy or by pericardial or pleural effusion cytology. We describe the pleural effusion cytologic features of a primary cardiac lymphoma in a 55-year-old woman who presented with progressive shortness of breath, fatigue, mild dizziness, dull chest ache, and lower extremity edema. Transthoracic echocardiography, CT, and MRI showed a large mass centered in the right atrium and extending into the right ventricle, associated with pericardial effusion and bilateral pleural effusions. Cytologic examination of the pleural fluid showed very large pleomorphic malignant cell, some of which were binucleated and multinucleated and had anaplastic features. Flow cytometry showed a kappa monotypic population of large cells coexpressing CD5, CD19, and CD20; and immunoperoxidase stains performed on the cell block sections showed that the large neoplastic cells were positive for CD20, PAX5, CD5, and MUM1 and showed a very high proliferation rate (over 90%) by Ki67 staining. The cytologic, flow cytometry, and immunohistochemistry findings established the diagnosis of de novo CD5-positive primary cardiac diffuse large B-cell lymphoma (DLBCL), anaplastic variant, which was confirmed by the subsequent endomyocardial biopsy. This is, to the best of our knowledge, the first report of de novo CD5-positive primary cardiac diffuse large B-cell lymphoma, and the first report of the anaplastic variant of DLBCL diagnosed by effusion cytology. Copyright © 2012 Wiley Periodicals, Inc., a Wiley company.

  8. Evolution of porosity and diffusivity associated with chemical weathering of a basalt clast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Navarre-Sitchler, A.; Steefel, C.I.; Yang, L.

    Weathering of rocks as a result of exposure to water and the atmosphere can cause significant changes in their chemistry and porosity. In low-porosity rocks, such as basalts, changes in porosity, resulting from chemical weathering, are likely to modify the rock's effective diffusivity and permeability, affecting the rate of solute transport and thus potentially the rate of overall weathering to the extent that transport is the rate limiting step. Changes in total porosity as a result of mineral dissolution and precipitation have typically been used to calculate effective diffusion coefficients through Archie's law for reactive transport simulations of chemical weathering,more » but this approach fails to account for unconnected porosity that does not contribute to transport. In this study, we combine synchrotron X-ray microcomputed tomography ({mu}CT) and laboratory and numerical diffusion experiments to examine changes in both total and effective porosity and effective diffusion coefficients across a weathering interface in a weathered basalt clast from Costa Rica. The {mu}CT data indicate that below a critical value of {approx}9%, the porosity is largely unconnected in the basalt clast. The {mu}CT data were further used to construct a numerical pore network model to determine upscaled, effective diffusivities as a function of total porosity (ranging from 3 to 30%) for comparison with diffusivities determined in laboratory tracer experiments. By using effective porosity as the scaling parameter and accounting for critical porosity, a model is developed that accurately predicts continuum-scale effective diffusivities across the weathering interface of the basalt clast.« less

  9. Apparent diffusion coefficient evaluation for secondary changes in the cerebellum of rats after middle cerebral artery occlusion

    PubMed Central

    Yang, Yunjun; Gao, Lingyun; Fu, Jun; Zhang, Jun; Li, Yuxin; Yin, Bo; Chen, Weijian; Geng, Daoying

    2013-01-01

    Supratentorial cerebral infarction can cause functional inhibition of remote regions such as the cerebellum, which may be relevant to diaschisis. This phenomenon is often analyzed using positron emission tomography and single photon emission CT. However, these methods are expensive and radioactive. Thus, the present study quantified the changes of infarction core and remote regions after unilateral middle cerebral artery occlusion using apparent diffusion coefficient values. Diffusion-weighted imaging showed that the area of infarction core gradually increased to involve the cerebral cortex with increasing infarction time. Diffusion weighted imaging signals were initially increased and then stabilized by 24 hours. With increasing infarction time, the apparent diffusion coefficient value in the infarction core and remote bilateral cerebellum both gradually decreased, and then slightly increased 3–24 hours after infarction. Apparent diffusion coefficient values at remote regions (cerebellum) varied along with the change of supratentorial infarction core, suggesting that the phenomenon of diaschisis existed at the remote regions. Thus, apparent diffusion coefficient values and diffusion weighted imaging can be used to detect early diaschisis. PMID:25206615

  10. Cutaneous sarcoidosis evaluated by FDG PET.

    PubMed

    Li, Yuxin; Berenji, Gholam R

    2011-07-01

    A 50-year-old man presented with initial complaints of diffuse skin pain and pruritus. Physical examination revealed scattered skin plaques and subcutaneous nodules with mild tenderness throughout the body. Skin biopsy demonstrated noncaseating epithelioid granulomas. Patient soon developed cough, fever with hot flashes, and shortness of breath on exertion. FDG PET/CT demonstrated diffuse cutaneous involvement throughout the body. Follow-up FDG PET/CT after treatment revealed a decrease in FDG uptake suggesting a good response to therapy.

  11. A Comparison of Ultrasonography, Computerised Tomography, and Conventional MRI Findings for Splenic Nodules Associated with Type 1 Gaucher’s Disease with Diffusion-Weighted MRI Findings

    PubMed Central

    Albayrak, Eda; Sonmezgoz, Fitnet; Ozmen, Zafer; Aktas, Fatma; Altunkas, Aysegul

    2017-01-01

    A 26-year-old female patient with Type 1 Gaucher’s disease (GD) was admitted to our clinic with complaints of stomachache and signs of anemia. The patient underwent ultrasonography (US), computerised tomography (CT), and magnetic resonance imaging (MRI) scan. Imaging studies revealed massive hepatosplenomegaly, choledocolithiasis, and six nodules in the spleen with a mean size of 14 mm. The nodules appeared hyperechoic, hypoechoic, and of mixed echogenicity on the US and hypodense on the CT. While the nodules were observed to be iso-hypointense in T1-weighted (T1WI) images, they appeared to be hyperintense in the T2-weighted (T2WI) images. There were no diffusion restrictions in these nodules that appeared on the diffusion-weighted magnetic resonance imaging (DWI). A nodule located at the lower pole was observed to be hypointense in the T2WI images. The nodule located at the lower pole, which appeared hypointense in T2WI series, had restricted diffusion upon DWI. In this study, we aimed to present the properties of splenic GD nodules using US, CT, and conventional MRI, together with DWI. This case report is the first to apply US, CT, and conventional MRI, together with DWI, to the splenic nodules associated with Gaucher’s disease. PMID:29386979

  12. Correlation between tissue metabolism and cellularity assessed by standardized uptake value and apparent diffusion coefficient in peritoneal metastasis.

    PubMed

    Yu, Xue; Lee, Elaine Yuen Phin; Lai, Vincent; Chan, Queenie

    2014-07-01

    To evaluate the correlation between standardized uptake value (SUV) (tissue metabolism) and apparent diffusion coefficient (ADC) (water diffusivity) in peritoneal metastases. Patients with peritoneal dissemination detected on (18)F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) were prospectively recruited for MRI examinations with informed consent and the study was approved by the local Institutional Review Board. FDG-PET/CT, diffusion-weighted imaging (DWI), MRI, and DWI/MRI images were independently reviewed by two radiologists based on visual analysis. SUVmax/SUVmean and ADCmin/ADCmean were obtained manually by drawing ROIs over the peritoneal metastases on FDG-PET/CT and DWI, respectively. Diagnostic characteristics of each technique were evaluated. Pearson's coefficient and McNemar and Kappa tests were used for statistical analysis. Eight patients were recruited for this prospective study and 34 peritoneal metastases were evaluated. ADCmean was significantly and negatively correlated with SUVmax (r = -0.528, P = 0.001) and SUVmean (r = -0.548, P = 0.001). ADCmin had similar correlation with SUVmax (r = -0.508, P = 0.002) and SUVmean (r = -0.513, P = 0.002). DWI/MRI had high diagnostic performance (accuracy = 98%) comparable to FDG-PET/CT, in peritoneal metastasis detection. Kappa values were excellent for all techniques. There was a significant inverse correlation between SUV and ADC. © 2013 Wiley Periodicals, Inc.

  13. Unified Heat Kernel Regression for Diffusion, Kernel Smoothing and Wavelets on Manifolds and Its Application to Mandible Growth Modeling in CT Images

    PubMed Central

    Chung, Moo K.; Qiu, Anqi; Seo, Seongho; Vorperian, Houri K.

    2014-01-01

    We present a novel kernel regression framework for smoothing scalar surface data using the Laplace-Beltrami eigenfunctions. Starting with the heat kernel constructed from the eigenfunctions, we formulate a new bivariate kernel regression framework as a weighted eigenfunction expansion with the heat kernel as the weights. The new kernel regression is mathematically equivalent to isotropic heat diffusion, kernel smoothing and recently popular diffusion wavelets. Unlike many previous partial differential equation based approaches involving diffusion, our approach represents the solution of diffusion analytically, reducing numerical inaccuracy and slow convergence. The numerical implementation is validated on a unit sphere using spherical harmonics. As an illustration, we have applied the method in characterizing the localized growth pattern of mandible surfaces obtained in CT images from subjects between ages 0 and 20 years by regressing the length of displacement vectors with respect to the template surface. PMID:25791435

  14. Prospective comparison of 68Ga-PSMA PET/CT, 18F-sodium fluoride PET/CT and diffusion weighted-MRI at for the detection of bone metastases in biochemically recurrent prostate cancer.

    PubMed

    Zacho, Helle D; Nielsen, Julie B; Afshar-Oromieh, Ali; Haberkorn, Uwe; deSouza, Nandita; De Paepe, Katja; Dettmann, Katja; Langkilde, Niels C; Haarmark, Christian; Fisker, Rune V; Arp, Dennis T; Carl, Jesper; Jensen, Jørgen B; Petersen, Lars J

    2018-06-06

    To prospectively compare diagnostic accuracies for detection of bone metastases by 68 Ga-PSMA PET/CT, 18 F-NaF PET/CT and diffusion-weighted MRI (DW 600 -MRI) in prostate cancer (PCa) patients with biochemical recurrence (BCR). Sixty-eight PCa patients with BCR participated in this prospective study. The patients underwent 68 Ga-PSMA PET/CT, a 18 F-NaF PET/CT and a DW 600 -MRI (performed in accordance with European Society of Urogenital Radiology guidelines, with b values of 0 and 600 s/mm 2 ). Bone lesions were categorized using a three-point scale (benign, malignant or equivocal for metastases) and a dichotomous scale (benign or metastatic) for each imaging modality by at least two experienced observers. A best valuable comparator was defined for each patient based on study-specific imaging, at least 12 months of clinical follow-up and any imaging prior to the study and during follow-up. Diagnostic performance was assessed using a sensitivity analysis where equivocal lesions were handled as non-metastatic and then as metastatic. Ten of the 68 patients were diagnosed with bone metastases. On a patient level, sensitivity, specificity and the area under the curve (AUC) by receiver operating characteristic analysis were, respectively, 0.80, 0.98-1.00 and 0.89-0.90 for 68 Ga-PSMA PET/CT (n = 68 patients); 0.90, 0.90-0.98 and 0.90-0.94 for 18 NaF PET/CT (n = 67 patients); and 0.25-0.38, 0.87-0.92 and 0.59-0.62 for DW 600 -MRI (n = 60 patients). The diagnostic performance of DW 600 -MRI was significantly lower than that of 68 Ga-PSMA PET/CT and 18 NaF PET/CT for diagnosing bone metastases (p < 0.01), and no significant difference in the AUC was seen between 68 Ga-PSMA PET/CT and 18 NaF PET/CT (p = 0.65). 68 Ga-PSMA PET/CT and 18 F-NaF PET/CT showed comparable and high diagnostic accuracies for detecting bone metastases in PCa patients with BCR. Both methods performed significantly better than DW 600 -MRI, which was inadequate for diagnosing bone metastases when conducted in accordance with European Society of Urogenital Radiology guidelines.

  15. 18F-FDG uptake and its clinical relevance in primary gastric lymphoma.

    PubMed

    Yi, Jun Ho; Kim, Seok Jin; Choi, Joon Young; Ko, Young Hyeh; Kim, Byung-Tae; Kim, Won Seog

    2010-06-01

    We studied the clinical relevance of (18)F-fluorodeoxyglucose ((18)F-FDG) uptake in patients with primary gastric lymphoma underwent positron emission tomography (PET)/ computed tomography (CT) scan. Forty-two patients with primary gastric lymphoma were analysed: 32 diffuse large B-cell lymphomas (DLBCL) and 10 extranodal marginal zone B-cell lymphomas of mucosa-associated lymphoid tissue (MALT lymphomas). The PET/CT scans were compared with clinical and pathologic features, and the results of CT and endoscopy. Nine patients were up-staged based on the results of their PET/CT scan compared to CT (seven DLBCLs, two MALT lymphomas) while six patients were down-staged by the PET/CT scan. The standard uptake value (SUV) was used as an indicator of a lesion with a high metabolic rate. The high SUVmax group, defined as an SUVmax >or= median value, was significantly associated with an advanced Lugano stage (p < 0.001). Three patients with DLBCL, who showed an initially high SUVmax, died of disease progression. Among 24 patients for whom follow-up PET/CT scan with endoscopy was performed, 11 patients with ulcerative or mucosal lesions showed residual (18)F-FDG uptake. All of these gastric lesions were grossly and pathologically benign lesions without evidence of lymphoma cells. In conclusion, PET/CT scan can be used in staging patients with primary gastric lymphoma; however, the residual (18)F-FDG uptake observed during follow-up should be interpreted cautiously and should be combined with endoscopy and multiple biopsies of the stomach. (c) 2009 John Wiley & Sons, Ltd.

  16. Diffusion capacity and CT measures of emphysema and airway wall thickness - relation to arterial oxygen tension in COPD patients.

    PubMed

    Saure, Eirunn Waatevik; Bakke, Per Sigvald; Lind Eagan, Tomas Mikal; Aanerud, Marianne; Jensen, Robert Leroy; Grydeland, Thomas Blix; Johannessen, Ane; Nilsen, Roy Miodini; Thorsen, Einar; Hardie, Jon Andrew

    2016-01-01

    Decreased diffusing capacity of the lung for carbon monoxide (DLCO) is associated with emphysema. DLCO is also related to decreased arterial oxygen tension (PaO2), but there are limited data on associations between PaO2 and computed tomography (CT) derived measures of emphysema and airway wall thickness. To examine whether CT measures of emphysema and airway wall thickness are associated with level of arterial oxygen tension beyond that provided by measurements of diffusion capacity and spirometry. The study sample consisted of 271 smoking or ex-smoking COPD patients from the Bergen COPD Cohort Study examined in 2007-2008. Emphysema was assessed as percent of low-attenuation areas<-950 Hounsfield units (%LAA), and airway wall thickness as standardised measure at an internal perimeter of 10 mm (AWT-Pi10). Multiple linear regression models were fitted with PaO2 as the outcome variable, and %LAA, AWT-Pi10, DLCO and carbon monoxide transfer coefficient (KCO) as main explanatory variables. The models were adjusted for sex, age, smoking status, and haemoglobin concentration, as well as forced expiratory volume in one second (FEV1). Sixty two per cent of the subjects were men, mean (SD) age was 64 (7) years, mean (SD) FEV1 in percent predicted was 50 (15)%, and mean PaO2 (SD) was 9.3 (1.1) kPa. The adjusted regression coefficient (CI) for PaO2 was -0.32 (-0.04-(-0.019)) per 10% increase in %LAA (p<0.01). When diffusion capacity and FEV1 were added to the model, respectively, the association lost its statistical significance. No relationship between airway wall thickness and PaO2 was found. CT assessment of airway wall thickness is not associated with arterial oxygen tension in COPD patients. Emphysema score measured by chest CT, is related to decreased PaO2, but cannot replace measurements of diffusion capacity in the clinical evaluation of hypoxaemia.

  17. Prognostic value of tumor necrosis at CT in diffuse large B-cell lymphoma.

    PubMed

    Adams, Hugo J A; de Klerk, John M H; Fijnheer, Rob; Dubois, Stefan V; Nievelstein, Rutger A J; Kwee, Thomas C

    2015-03-01

    To determine the prognostic value of tumor necrosis at computed tomography (CT) in newly diagnosed diffuse large B-cell lymphoma (DLBCL). This retrospective study included 51 patients with newly diagnosed DLBCL who had undergone both unenhanced and intravenous contrast-enhanced CT before R-CHOP (rituximab, cyclophosphamide, hydroxydaunorubicin, oncovin and prednisolone) chemo-immunotherapy. Presence of tumor necrosis was visually and quantitatively assessed at CT. Associations between tumor necrosis status at CT and the National Comprehensive Cancer Network (NCCN) International Prognostic Index (IPI) factors were assessed. Cox regression analysis was used to determine the prognostic impact of NCCN-IPI scores and tumor necrosis status at CT. There were no correlations between tumor necrosis status at CT and the NCCN-IPI factors categorized age (ρ=-0.042, P=0.765), categorized lactate dehydrogenase (LDH) ratio (ρ=0.201, P=0.156), extranodal disease in major organs (φ=-0.245, P=0.083), Ann Arbor stage III/IV disease (φ=-0.208, P=0.141), and Eastern Cooperative Oncology Group (ECOG) performance status (φ=0.015, P=0.914). In the multivariate Cox proportional hazards model, only tumor necrosis status at CT was an independent predictive factor of progression-free survival (P=0.003) and overall survival (P=0.004). The findings of this study indicate the prognostic potential of tumor necrosis at CT in newly diagnosed DLBCL. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. CT in the clinical and prognostic evaluation of acute graft-vs-host disease of the gastrointestinal tract

    PubMed Central

    Shimoni, A; Rimon, U; Hertz, M; Yerushalmi, R; Amitai, M; Portnoy, O; Guranda, L; Nagler, A; Apter, S

    2012-01-01

    Objective To determine the role of abdominal CT in assessment of severity and prognosis of patients with acute gastrointestinal (GI) graft-vs-host disease (GVHD). Methods During 2000–2004, 41 patients with a clinical diagnosis of acute GI-GVHD were evaluated. CTs were examined for intestinal and extra-intestinal abnormalities, and correlated with clinical staging and outcome. Results 20 patients had GVHD clinical Stage I–II and 21 had Stage III–IV. 39 (95%) had abnormal CT appearances. The most consistent finding was bowel wall thickening: small (n=14, 34%) or large (n=5, 12%) bowel, or both (n=20, 49%). Other manifestations included bowel dilatation (n=7, 17%), mucosal enhancement (n=6, 15%) and gastric wall thickening (n=9, 38%). Extra-intestinal findings included mesenteric stranding (n=25, 61%), ascites (n=17, 41%), biliary abnormalities (n=12, 29%) and urinary excretion of orally administered gastrografin (n=12, 44%). Diffuse small-bowel thickening and any involvement of the large bowel were associated with severe clinical presentation. Diffuse small-bowel disease correlated with poor prognosis. 8 of 21 patients responded to therapy, compared with 15 of 20 patients with other patterns (p=0.02), and the cumulative incidence of GVHD-related death was 62% and 24%, respectively (p=0.01). Overall survival was not significantly different between patients with diffuse small-bowel disease and patients with other patterns (p=0.31). Colonic disease correlated with severity of GVHD (p=0.04), but not with response to therapy or prognosis (p=0.45). Conclusion GVHD often presented with abdominal CT abnormalities. Diffuse small-bowel disease was associated with poor therapeutic response. CT may play a role in supporting clinical diagnosis of GI GVHD and determining prognosis. PMID:22128129

  19. Normal Lung Quantification in Usual Interstitial Pneumonia Pattern: The Impact of Threshold-based Volumetric CT Analysis for the Staging of Idiopathic Pulmonary Fibrosis.

    PubMed

    Ohkubo, Hirotsugu; Kanemitsu, Yoshihiro; Uemura, Takehiro; Takakuwa, Osamu; Takemura, Masaya; Maeno, Ken; Ito, Yutaka; Oguri, Tetsuya; Kazawa, Nobutaka; Mikami, Ryuji; Niimi, Akio

    2016-01-01

    Although several computer-aided computed tomography (CT) analysis methods have been reported to objectively assess the disease severity and progression of idiopathic pulmonary fibrosis (IPF), it is unclear which method is most practical. A universal severity classification system has not yet been adopted for IPF. The purpose of this study was to test the correlation between quantitative-CT indices and lung physiology variables and to determine the ability of such indices to predict disease severity in IPF. A total of 27 IPF patients showing radiological UIP pattern on high-resolution (HR) CT were retrospectively enrolled. Staging of IPF was performed according to two classification systems: the Japanese and GAP (gender, age, and physiology) staging systems. CT images were assessed using a commercially available CT imaging analysis workstation, and the whole-lung mean CT value (MCT), the normally attenuated lung volume as defined from -950 HU to -701 Hounsfield unit (NL), the volume of the whole lung (WL), and the percentage of NL to WL (NL%), were calculated. CT indices (MCT, WL, and NL) closely correlated with lung physiology variables. Among them, NL strongly correlated with forced vital capacity (FVC) (r = 0.92, P <0.0001). NL% showed a large area under the receiver operating characteristic curve for detecting patients in the moderate or advanced stages of IPF. Multivariable logistic regression analyses showed that NL% is significantly more useful than the percentages of predicted FVC and predicted diffusing capacity of the lungs for carbon monoxide (Japanese stage II/III/IV [odds ratio, 0.73; 95% confidence intervals (CI), 0.48 to 0.92; P < 0.01]; III/IV [odds ratio. 0.80; 95% CI 0.59 to 0.96; P < 0.01]; GAP stage II/III [odds ratio, 0.79; 95% CI, 0.56 to 0.97; P < 0.05]). The measurement of NL% by threshold-based volumetric CT analysis may help improve IPF staging.

  20. [The diagnostic value of dual-energy CT and 3 Tesla MRI in the diagnosis of German Mardi Gras donuts--where is the mustard, where is the custard and where is the jam?].

    PubMed

    Morhard, D; Dietrich, O; Reiser, M; Ertl-Wagner, B

    2008-04-01

    As a Mardi Gras joke, the original jam or custard fillings of German Mardi Gras donuts are frequently replaced with mustard which cannot be identified on the outside of the donut. The aim of our study was to evaluate the impact of modern CT and MRI techniques on the diagnostic evaluation of donuts filled with mustard, jam or custard. 4 commercially available donuts were included in the study. One was filled with custard (PK) and one with jam (MK). Two donuts were specifically prepared and filled with Bavarian mustard (SK1) or extra-hot (SK2) mustard. 3 Tesla MRI was performed with T 2- and T 1-weighted STIR, diffusion and susceptibility-weighted (SWI) sequences. In addition, the donuts underwent dual-energy CT. PK was able to be easily differentiated from the other donuts due to its hyperintensity in the STIR sequences and hypointensity in the T 1-weighted sequences. MK was able to be differentiated from S 1K and S 2K on the basis of its diffusion properties. S 1K demonstrated a pronounced heterogeneity of its matrix, especially in SWI. In CT, PK showed a pronounced hypoattenuation with negative Hounsfield units in contrast to the strongly hyperdense MK, S 1K and S 2K. S 1K and S 2K demonstrated X-ray attenuation considerably dependent on the X-ray energy. Donuts filled with jam, custard or mustard can be readily differentiated by modern MRI and CT techniques. Therefore, eating a mustard-filled donut can be reliably avoided.

  1. Acute intestinal obstruction due to metastatic lung cancer—case report

    PubMed Central

    2017-01-01

    Abstract We present a case of male patient, who was referred to our department because of acute intestinal obstruction, which was the initial clinical symptom of primary lung cancer. The abdominal computed tomography (CT) prior to the emergency operation showed small intestinal obstruction and metastases to both adrenal glands. The patient underwent an emergency abdominal exploratory laparotomy, that confirmed small bowel obstruction and diffuse metastatic lesions along the entire small bowel length. During the operation we took a sample of one metastasis for pathological examination and we created an intestinal bypass to relieve small bowel obstruction. The pathologist suspected to primary lung cancer according to the immunohistochemical staining. The chest CT after the emergency operation showed a large primary tumor in the left upper pulmonary lobe. PMID:28458837

  2. Magnetic resonance imaging in central nervous system sarcoidosis.

    PubMed

    Miller, D H; Kendall, B E; Barter, S; Johnson, G; MacManus, D G; Logsdail, S J; Ormerod, I E; McDonald, W I

    1988-03-01

    We performed brain MRIs on 21 patients with CNS sarcoidosis. Brain CTs were performed in 18 of these. Parenchymal lesions were seen in 17 of 21 with MRI, compared with 9 of 18 with CT. MRI detected a greater number of parenchymal lesions in cases where both CT and MRI were positive, and some lesions appeared more extensive with MRI than with CT. The most common MRI pattern was one of periventricular and multifocal white matter lesions (14 cases). Such a pattern is not specific, and other recognized causes for it were identified in four cases. It is likely, however, that sarcoid tissue causes this pattern in some cases, and confirmation was obtained from cerebral biopsy in one. In six patients, the white matter changes were indistinguishable from those seen in multiple sclerosis. Contrast-enhanced CT in two patients showed diffuse meningeal involvement not seen with MRI. MRI is the investigation of choice in detecting parenchymal changes in the brain of patients with CNS sarcoidosis and may prove useful in monitoring treatment in such cases.

  3. Pulmonary 3He Magnetic Resonance Imaging Biomarkers of Regional Airspace Enlargement in Alpha-1 Antitrypsin Deficiency.

    PubMed

    Lessard, Eric; Young, Heather M; Bhalla, Anurag; Pike, Damien; Sheikh, Khadija; McCormack, David G; Ouriadov, Alexei; Parraga, Grace

    2017-11-01

    Thoracic x-ray computed tomography (CT) and hyperpolarized 3 He magnetic resonance imaging (MRI) provide quantitative measurements of airspace enlargement in patients with emphysema. For patients with panlobular emphysema due to alpha-1 antitrypsin deficiency (AATD), sensitive biomarkers of disease progression and response to therapy have been difficult to develop and exploit, especially those biomarkers that correlate with outcomes like quality of life. Here, our objective was to generate and compare CT and diffusion-weighted inhaled-gas MRI measurements of emphysema including apparent diffusion coefficient (ADC) and MRI-derived mean linear intercept (L m ) in patients with AATD, chronic obstructive pulmonary disease (COPD) ex-smokers, and elderly never-smokers. We enrolled patients with AATD (n = 8; 57 ± 7 years), ex-smokers with COPD (n = 8; 77 ± 6 years), and a control group of never-smokers (n = 5; 64 ± 2 years) who underwent thoracic CT, MRI, spirometry, plethysmography, the St. George's Respiratory Questionnaire, and the 6-minute walk test during a single 2-hour visit. MRI-derived ADC, L m , surface-to-volume ratio, and ventilation defect percent were generated for the apical, basal, and whole lung as was CT lung area ≤-950 Hounsfield units (RA 950 ), low attenuating clusters, and airway count. In patients with AATD, there was a significantly different MRI-derived ADC (P = .03), L m (P < .0001), and surface-to-volume ratio (P < .0001), but not diffusing capacity of carbon monoxide, residual volume or total lung capacity, or CT RA 950 (P > .05) compared to COPD ex-smokers with a significantly different St. George's Respiratory Questionnaire. In this proof-of-concept demonstration, we evaluated CT and MRI lung emphysema measurements and observed significantly worse MRI biomarkers of emphysema in patients with AATD compared to patients with COPD, although CT RA 950 and diffusing capacity of carbon monoxide were not significantly different, underscoring the sensitivity of MRI measurements of AATD emphysema. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  4. Whole-body diffusion-weighted magnetic resonance imaging (WB-DW-MRI) vs choline-positron emission tomography-computed tomography (choline-PET/CT) for selecting treatments in recurrent prostate cancer.

    PubMed

    Conde-Moreno, A J; Herrando-Parreño, G; Muelas-Soria, R; Ferrer-Rebolleda, J; Broseta-Torres, R; Cozar-Santiago, M P; García-Piñón, F; Ferrer-Albiach, C

    2017-05-01

    To determine the effectiveness of whole-body diffusion-weighted magnetic resonance imaging (WB-DW-MRI) in detecting metastases by comparing the results with those from choline-positron emission tomography-computed tomography (choline-PET/CT) in patients with biochemical relapse after primary treatment, and no metastases in bone scintigraphy, CT and/or pelvic MRI, or metastatic/oligometastatic prostate cancer (PCa). Patients with this disease profile who could benefit from treatment with stereotactic body radiation therapy (SBRT) were selected and their responses to these techniques were rated. This was a prospective, controlled, unicentric study, involving 46 consecutive patients from our centre who presented biochemical relapse after adjuvant, salvage or radical treatment with external beam radiotherapy, or brachytherapy. After initial tests (bone scintigraphy, CT, pelvic MRI), 35 patients with oligometastases or without them were selected. 11 patients with multiple metastases were excluded from the study. WB-DW-MRI and choline-PET/CT was then performed on each patient within 1 week. The results were interpreted by specialists in nuclear medicine and MRI. If they were candidates for treatment with ablative SBRT (SABR), they were then evaluated every three months with both tests. Choline-PET/CT detected lesions in 16 patients that were not observable using WB-DW-MRI. The results were consistent in seven patients and in three cases, a lesion was observed using WB-DW-MRI that was not detected with choline-PET/CT. The Kappa value obtained was 0.133 (p = 0.089); the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of WB-DW-MRI were estimated at 44.93, 64.29, 86.11, and 19.15%, respectively. For choline-PET/CT patients, the sensitivity, specificity, PPV, and NPV were 97.10, 58.33, 93.06, and 77.78%, respectively. Choline-PET/CT has a high global sensitivity while WB-DW-MRI has a high specificity, and so they are complementary techniques. Future studies with more enrolled patients and a longer follow-up period will be required to confirm these data. The initial data show that the best technique for evaluating response after SBRT is choline-PET/CT. Trial registration number NCT02858128.

  5. Measuring the diffusion coefficient of ganglioside on cell membrane by fluorescence correlation spectroscopy

    NASA Astrophysics Data System (ADS)

    Dong, Shiqing; You, Minghai; Chen, Jianling; Zhou, Jie; Xie, Shusen; Yang, Hongqin

    2017-06-01

    The fluidity of proteins and lipids on cell membrane plays an important role in cell’s physiological functions. Fluorescence correlation spectroscopy (FCS) is an effective technique to detect the rapid dynamic behaviors of proteins and/or lipids in living cells. In this study, we used the rhodamine6G solution to optimize the FCS system. And, cholera toxin B subunit (CT-B) was used to label ganglioside on living Hela cell membranes. The diffusion time and coefficients of ganglioside can be obtained through fitting the autocorrelation curve based on the model of two-dimensional cell membrane. The results showed that the diffusion coefficients of ganglioside distributed within a wide range. It revealed the lateral diffusion of lipids on cell membrane was inhomogeneous, which was due to different microstructures of cytoplasmic membrane. The study provides a helpful method for further studying the dynamic characteristics of proteins and lipids molecules on living cell membrane.

  6. Diffusion processes in tumors: A nuclear medicine approach

    NASA Astrophysics Data System (ADS)

    Amaya, Helman

    2016-07-01

    The number of counts used in nuclear medicine imaging techniques, only provides physical information about the desintegration of the nucleus present in the the radiotracer molecules that were uptaken in a particular anatomical region, but that information is not a real metabolic information. For this reason a mathematical method was used to find a correlation between number of counts and 18F-FDG mass concentration. This correlation allows a better interpretation of the results obtained in the study of diffusive processes in an agar phantom, and based on it, an image from the PETCETIX DICOM sample image set from OsiriX-viewer software was processed. PET-CT gradient magnitude and Laplacian images could show direct information on diffusive processes for radiopharmaceuticals that enter into the cells by simple diffusion. In the case of the radiopharmaceutical 18F-FDG is necessary to include pharmacokinetic models, to make a correct interpretation of the gradient magnitude and Laplacian of counts images.

  7. CT-based Diagnosis of Diffuse Coronary Artery Disease on the Basis of Scaling Power Laws

    PubMed Central

    Huo, Yunlong; Wischgoll, Thomas; Choy, Jenny Susana; Sola, Srikanth; Navia, Jose L.; Teague, Shawn D.; Bhatt, Deepak L.

    2013-01-01

    Purpose: To provide proof of concept for a diagnostic method to assess diffuse coronary artery disease (CAD) on the basis of coronary computed tomography (CT) angiography. Materials and Methods: The study was approved by the Cleveland Clinic Institutional Review Board, and all subjects gave informed consent. Morphometric data from the epicardial coronary artery tree, determined with CT angiography in 120 subjects (89 patients with metabolic syndrome and 31 age- and sex-matched control subjects) were analyzed on the basis of the scaling power law. Results obtained in patients with metabolic syndrome and control subjects were compared statistically. Results: The mean lumen cross-sectional area (ie, lumen cross-sectional area averaged over each vessel of an epicardial coronary artery tree) and sum of intravascular volume in patients with metabolic syndrome (0.039 cm2 ± 0.015 [standard deviation] and 2.71 cm3 ± 1.75, respectively) were significantly less than those in control subjects (0.054 cm2± 0.015 and 3.29 cm3± 1.77, respectively; P < .05). The length-volume power law showed coefficients of 27.0 cm−4/3 ± 9.0 (R2 = 0.91 ± 0.08) for patients with metabolic syndrome and 19.9 cm−4/3 ± 4.3 (R2 = 0.92 ± 0.07) for control subjects (P < .05). The probability frequency shows that more than 65% of patients with metabolic syndrome had a coefficient of 23 or more for the length-volume scaling power law, whereas approximately 90% of the control subjects had a coefficient of less than 23. Conclusion: The retrospective scaling analysis provides a quantitative rationale for diagnosis of diffuse CAD. © RSNA, 2013 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13122181/-/DC1 PMID:23616633

  8. Interstitial pneumonitis after acetylene welding: a case report.

    PubMed

    Brvar, Miran

    2014-01-01

    Acetylene is a colorless gas commonly used for welding. It acts mainly as a simple asphyxiant. In this paper, however, we present a patient who developed a severe interstitial pneumonitis after acetylene exposure during aluminum welding. A 44-year old man was welding with acetylene, argon and aluminum electrode sticks in a non-ventilated aluminum tank for 2 h. Four hours after welding dyspnea appeared and 22 h later he was admitted at the Emergency Department due to severe respiratory insufficiency with pO2 = 6.7 kPa. Chest X-ray showed diffuse interstitial infiltration. Pulmonary function and gas diffusion tests revealed a severe restriction (55% of predictive volume) and impaired diffusion capacity (47% of predicted capacity). Toxic interstitial pneumonitis was diagnosed and high-dose systemic corticosteroid methylprednisolone and inhalatory corticosteroid fluticasone therapy was started. Computed Tomography (CT) of the lungs showed a diffuse patchy ground-glass opacity with no signs of small airway disease associated with interstitial pneumonitis. Corticosteroid therapy was continued for the next 8 weeks gradually reducing the doses. The patient's follow-up did not show any deterioration of respiratory function. In conclusion, acetylene welding might result in severe toxic interstitial pneumonitis that improves after an early systemic and inhalatory corticosteroid therapy.

  9. Interim 18F-FGD PET/CT may not predict the outcome in primary central nervous system lymphoma patients treated with sequential treatment with methotrexate and cytarabine.

    PubMed

    Jo, Jae-Cheol; Yoon, Dok Hyun; Kim, Shin; Lee, Kyoungmin; Kang, Eun Hee; Park, Jung Sun; Ryu, Jin-Sook; Huh, Jooryung; Park, Chan-Sik; Kim, Jong Hoon; Lee, Sang Wook; Suh, Cheolwon

    2017-09-01

    18 F-fluoro-2-dexoy-D-glucose-positron emission tomography (PET)/computed tomography (CT) is a useful imaging technique for monitoring the treatment response in lymphoma cases. We investigated the value of interim brain PET/CT (I-PET/CT) for monitoring the response to intensive methotrexate-based chemotherapy in primary central nervous system lymphoma (PCNSL) patients with diffuse large B cell lymphoma (DLBCL). Of the 76 PCNSL patients treated with intensive methotrexate and cytarabine chemotherapy between September 2006 and December 2012, 66 patients with DLBCL were included in this study. The patient cohort of 66 individuals comprised 43 men and 23 women with a median age of 59 years (range, 17-75 years). During chemotherapy, 36 patients (54.5%) showed a negative metabolism on I-PET/CT, and 47 (71.2%) were negative on final (F) PET/CT. The baseline characteristics were similar between I-PET/CT-negative (n = 36) and I-PET/CT-positive patients (n = 30) except ECOG performance status. After a median follow-up of 27.5 months, there was no difference in the progression-free survival (PFS; P = 0.701) or overall survival (OS; P = 0.620) between the I-PET/CT-negative and I-PET/CT-positive groups. However, PFS in the F-PET/CT-negative group was significantly longer than that in the F-PET/CT-positive group (P < 0.001) without a significant difference in OS (P = 0.892). I-PET/CT may not predict the survival outcome of PCNSL patients with DLBCL treated with intensive methotrexate and cytarabine chemotherapy. Prospective trials are required to fully evaluate the role of I-PET/CT.

  10. ctDNA DLBCL Detection Lancet Oncology

    Cancer.gov

    Measurement of circulating tumor DNA in blood can be used to detect disease recurrence in patients with a curable form of cancer known as diffuse large B-cell lymphoma (DLBCL). In most patients, measurement of ctDNA enabled detection of microscopic diseas

  11. Dual Contrast CT Method Enables Diagnostics of Cartilage Injuries and Degeneration Using a Single CT Image.

    PubMed

    Saukko, Annina E A; Honkanen, Juuso T J; Xu, Wujun; Väänänen, Sami P; Jurvelin, Jukka S; Lehto, Vesa-Pekka; Töyräs, Juha

    2017-12-01

    Cartilage injuries may be detected using contrast-enhanced computed tomography (CECT) by observing variations in distribution of anionic contrast agent within cartilage. Currently, clinical CECT enables detection of injuries and related post-traumatic degeneration based on two subsequent CT scans. The first scan allows segmentation of articular surfaces and lesions while the latter scan allows evaluation of tissue properties. Segmentation of articular surfaces from the latter scan is difficult since the contrast agent diffusion diminishes the image contrast at surfaces. We hypothesize that this can be overcome by mixing anionic contrast agent (ioxaglate) with bismuth oxide nanoparticles (BINPs) too large to diffuse into cartilage, inducing a high contrast at the surfaces. Here, a dual contrast method employing this mixture is evaluated by determining the depth-wise X-ray attenuation profiles in intact, enzymatically degraded, and mechanically injured osteochondral samples (n = 3 × 10) using a microCT immediately and at 45 min after immersion in contrast agent. BiNPs were unable to diffuse into cartilage, producing high contrast at articular surfaces. Ioxaglate enabled the detection of enzymatic and mechanical degeneration. In conclusion, the dual contrast method allowed detection of injuries and degeneration simultaneously with accurate cartilage segmentation using a single scan conducted at 45 min after contrast agent administration.

  12. Diagnosis of Grave's disease with pulmonary hypertension on chest CT.

    PubMed

    Lee, Hwa Yeon; Yoo, Seung Min; Kim, Hye Rin; Chun, Eun Ju; White, Charles S

    To evaluate the diagnostic accuracy of chest CT findings to diagnose Grave's disease in pulmonary hypertension. We retrospectively evaluated chest CT and the medical records of 13 patients with Grave's disease with (n=6) or without pulmonary hypertension (n=7) and in 17 control patients. Presence of iso-attenuation of diffusely enlarged thyroid glands compared with adjacent neck muscle on non-enhanced CT as a diagnostic clue of Grave's disease, and assessment of pulmonary hypertension on CT has high diagnostic accuracy. Chest CT has the potential to diagnose Grave's disease with pulmonary hypertension in the absence of other information. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Computed tomography-based diagnosis of diffuse compensatory enlargement of coronary arteries using scaling power laws.

    PubMed

    Huo, Yunlong; Choy, Jenny Susana; Wischgoll, Thomas; Luo, Tong; Teague, Shawn D; Bhatt, Deepak L; Kassab, Ghassan S

    2013-04-06

    Glagov's positive remodelling in the early stages of coronary atherosclerosis often results in plaque rupture and acute events. Because positive remodelling is generally diffused along the epicardial coronary arterial tree, it is difficult to diagnose non-invasively. Hence, the objective of the study is to assess the use of scaling power law for the diagnosis of positive remodelling of coronary arteries based on computed tomography (CT) images. Epicardial coronary arterial trees were reconstructed from CT scans of six Ossabaw pigs fed on a high-fat, high-cholesterol, atherogenic diet for eight months as well as the same number of body-weight-matched farm pigs fed on a lean chow (101.9±16.1 versus 91.5±13.1 kg). The high-fat diet Ossabaw pig model showed diffuse positive remodelling of epicardial coronary arteries. Good fit of measured coronary data to the length-volume scaling power law ( where L(c) and V(c) are crown length and volume) were found for both the high-fat and control groups (R(2) = 0.95±0.04 and 0.99±0.01, respectively). The coefficient, K(LV), decreased significantly in the high-fat diet group when compared with the control (14.6±2.6 versus 40.9±5.6). The flow-length scaling power law, however, was nearly unaffected by the positive remodelling. The length-volume and flow-length scaling power laws were preserved in epicardial coronary arterial trees after positive remodelling. K(LV) < 18 in the length-volume scaling relation is a good index of positive remodelling of coronary arteries. These findings provide a clinical rationale for simple, accurate and non-invasive diagnosis of positive remodelling of coronary arteries, using conventional CT scans.

  14. Transport of Carbon Tetrachloride in a Fractured Vadose Zone due to Atmospheric Pressure Fluctuations, Diffusion, and Vapor Density

    NASA Astrophysics Data System (ADS)

    McCray, J. E.; Downs, W.; Falta, R. W.; Housley, T.

    2005-12-01

    DNAPL sources of carbon tetrachloride (CT) vapors are of interest at the Radioactive Waste Management Complex (RWMC) at the Idaho National Engineering and Environmental Laboratory (INEEL). The site is underlain by thick fractured basalt that includes sedimentary interbeds, each are a few meters thick. Daily atmospheric pressure fluctuations serve as driving forces for CT vapor transport in the subsurface. Other important transport processes for vapor movement include gas-phase diffusion and density-driven transport. The objective of this research is to investigate the influence and relative importance of these processes on gaseous transport of CT. Gas pressure and vapor concentration measurements were conducted at various depths in two wells. A numerical multiphase flow model (TOUGH2), calibrated to field pressure data, is used to conduct sensitivity analyses to elucidate the importance of the different transport mechanisms. Results show that the basalt is highly permeable to vertical air flow. The pressure dampening occurs mainly in the sedimentary interbeds. Model-calibrated permeability values for the interbeds are similar to those obtained in a study by the U.S. Geological Survey for shallow sediments, and an order of magnitude higher than column-scale values obtained by previous studies conducted by INEEL scientists. The transport simulations indicate that considering the effect of barometric pressure changes is critical to simulating transport of pollutants in the vadose zone above the DNAPL source. Predicted concentrations can be orders of magnitude smaller than actual concentrations if the effect is not considered. Below the DNAPL vapor source, accounting for density and diffusion alone would yield acceptable results provided that a 20% error in concentrations are acceptable, and that simulating concentrations trends (and not actual concentrations) is the primary goal.

  15. Neuroradiologic characteristics of astroblastoma and systematic review of the literature: 2 new cases and 125 cases reported in 59 publications.

    PubMed

    Cunningham, Danielle A; Lowe, Lisa H; Shao, Lei; Acosta, Natasha R

    2016-08-01

    Astroblastoma is a rare tumor of uncertain origin most commonly presenting in the cerebrum of children and young adults. The literature contains only case reports and small series regarding its radiologic features. This systematic review is the largest study of imaging findings of astroblastoma to date and serves to identify features that might differentiate it from other neoplasms. This study describes the imaging features of astroblastoma based on a systematic review of the literature and two new cases. We conducted a PubMed and Google Scholar database search that identified 59 publications containing 125 cases of pathology-confirmed astroblastoma, and we also added two new cases from our own institution. Data collected include patient age, gender, tumor location, morphology, calcifications and calvarial changes. We recorded findings on CT, MRI, diffusion-weighted imaging (DWI), MR spectroscopy, positron emission tomography (PET) and catheter angiography. Age at diagnosis ranged 0-70 years (mean 18 years; median 14 years). Female-to-male ratio was 8:1. Of 127 cases, 66 reported CT, 78 reported MRI and 47 reported both findings. Not all authors reported all features, but the tumor features reported included supratentorial in 96% (122/127), superficial in 72% (48/67), well-demarcated in 96% (79/82), mixed cystic-solid in 93% (79/85), and enhancing in 99% (78/79). On CT, 84% (26/31) of astroblastomas were hyperattenuated, 73% (27/37) had calcifications and 7 cases reported adjacent calvarial erosion. Astroblastomas were hypointense on T1-W in 58% (26/45) and on T2-W in 50% (23/46) of MRI sequences. Peritumoral edema was present in 80% (40/50) of cases but was typically described as slight. Six cases included DWI findings, with 100% showing restricted diffusion. On MR spectroscopy, 100% (5/5) showed nonspecific tumor spectra with elevated choline and decreased N-acetylaspartate (NAA). PET revealed nonspecific reduced uptake of [F-18] 2-fluoro-2-deoxyglucose ((18)F-FDG) and increased uptake of [11C]-Methionine in 100% (3/3) of cases. Catheter angiography findings (n=12) were variable, including hypervascularity in 67%, arteriovenous shunting in 33% and avascular areas in 25%. Astroblastomas occur most often in adolescent girls. Imaging often shows a supratentorial, superficial, well-defined, cystic-solid enhancing mass. On CT, most are hyperattenuated, have calcifications, and may remodel adjacent bone if superficial. MRI characteristically reveals a hypointense mass on T1-W and T2-W sequences with restricted diffusion. MR spectroscopy, PET and catheter angiography findings are nonspecific.

  16. Semiautomated spleen volumetry with diffusion-weighted MR imaging.

    PubMed

    Lee, Jeongjin; Kim, Kyoung Won; Lee, Ho; Lee, So Jung; Choi, Sanghyun; Jeong, Woo Kyoung; Kye, Heewon; Song, Gi-Won; Hwang, Shin; Lee, Sung-Gyu

    2012-07-01

    In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-MR images. Manual spleen volumetry was performed on DW-MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW-MR (r = 0.99; P < 0.0001; mean percentage absolute difference, 1.43 ± 0.94) and CT (r = 0.99; P < 0.0001; 1.76 ± 1.07). Mean total processing time for semiautomated volumetry was significantly shorter compared to that of manual volumetry with DW-MR (P < 0.0001) and CT (P < 0.0001). In conclusion, semiautomated spleen volumetry with DW-MR images can be performed rapidly and accurately when compared with standard manual volumetry. Copyright © 2011 Wiley Periodicals, Inc.

  17. Limited reliability of computed tomographic perfusion acute infarct volume measurements compared with diffusion-weighted imaging in anterior circulation stroke.

    PubMed

    Schaefer, Pamela W; Souza, Leticia; Kamalian, Shervin; Hirsch, Joshua A; Yoo, Albert J; Kamalian, Shahmir; Gonzalez, R Gilberto; Lev, Michael H

    2015-02-01

    Diffusion-weighted imaging (DWI) can reliably identify critically ischemic tissue shortly after stroke onset. We tested whether thresholded computed tomographic cerebral blood flow (CT-CBF) and CT-cerebral blood volume (CT-CBV) maps are sufficiently accurate to substitute for DWI for estimating the critically ischemic tissue volume. Ischemic volumes of 55 patients with acute anterior circulation stroke were assessed on DWI by visual segmentation and on CT-CBF and CT-CBV with segmentation using 15% and 30% thresholds, respectively. The contrast:noise ratios of ischemic regions on the DWI and CT perfusion (CTP) images were measured. Correlation and Bland-Altman analyses were used to assess the reliability of CTP. Mean contrast:noise ratios for DWI, CT-CBF, and CT-CBV were 4.3, 0.9, and 0.4, respectively. CTP and DWI lesion volumes were highly correlated (R(2)=0.87 for CT-CBF; R(2)=0.83 for CT-CBV; P<0.001). Bland-Altman analyses revealed little systemic bias (-2.6 mL) but high measurement variability (95% confidence interval, ±56.7 mL) between mean CT-CBF and DWI lesion volumes, and systemic bias (-26 mL) and high measurement variability (95% confidence interval, ±64.0 mL) between mean CT-CBV and DWI lesion volumes. A simulated treatment study demonstrated that using CTP-CBF instead of DWI for detecting a statistically significant effect would require at least twice as many patients. The poor contrast:noise ratios of CT-CBV and CT-CBF compared with those of DWI result in large measurement error, making it problematic to substitute CTP for DWI in selecting individual acute stroke patients for treatment. CTP could be used for treatment studies of patient groups, but the number of patients needed to identify a significant effect is much higher than the number needed if DWI is used. © 2014 American Heart Association, Inc.

  18. Shortened Mean Transit Time in CT Perfusion With Singular Value Decomposition Analysis in Acute Cerebral Infarction: Quantitative Evaluation and Comparison With Various CT Perfusion Parameters.

    PubMed

    Murayama, Kazuhiro; Katada, Kazuhiro; Hayakawa, Motoharu; Toyama, Hiroshi

    We aimed to clarify the cause of shortened mean transit time (MTT) in acute ischemic cerebrovascular disease and examined its relationship with reperfusion. Twenty-three patients with acute ischemic cerebrovascular disease underwent whole-brain computed tomography perfusion (CTP). The maximum MTT (MTTmax), minimum MTT (MTTmin), ratio of maximum and minimum MTT (MTTmin/max), and minimum cerebral blood volume (CBV) (CBVmin) were measured by automatic region of interest analysis. Diffusion weighted image was performed to calculate infarction volume. We compared these CTP parameters between reperfusion and nonreperfusion groups and calculated correlation coefficients between the infarction core volume and CTP parameters. Significant differences were observed between reperfusion and nonreperfusion groups (MTTmin/max: P = 0.014; CBVmin ratio: P = 0.038). Regression analysis of CTP and high-intensity volume on diffusion weighted image showed negative correlation (CBVmin ratio: r = -0.41; MTTmin/max: r = -0.30; MTTmin ratio: r = -0.27). A region of shortened MTT indicated obstructed blood flow, which was attributed to the singular value decomposition method error.

  19. Comparison of DWI and PET/CT in evaluation of lymph node metastasis in uterine cancer

    PubMed Central

    Kitajima, Kazuhiro; Yamasaki, Erena; Kaji, Yasushi; Murakami, Koji; Sugimura, Kazuro

    2012-01-01

    AIM: To investigate diffusion-weighted imaging (DWI) and positron emission tomography and computed tomography (PET/CT) with IV contrast for the preoperative evaluation of pelvic lymph node (LN) metastasis in uterine cancer. METHODS: Twenty-five patients with endometrial or cervical cancer who underwent both DWI and PET/CT before pelvic lymphadenectomy were included in this study. For area specific analysis, LNs were divided into eight regions: both common iliac, external iliac, internal iliac areas, and obturator areas. The classification for malignancy on DWI was a focally abnormal signal intensity in a location that corresponded to the LN chains on the T1WI and T2WI. The criterion for malignancy on PET/CT images was increased tracer uptake by the LN. RESULTS: A total of 36 pathologically positive LN areas were found in 9 patients. With DWI, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy for detecting metastatic LNs on an LN area-by-area analysis were 83.3%, 51.2%, 27.3%, 93.3% and 57.0%, respectively, while the corresponding values for PET/CT were 38.9%, 96.3%, 70.0%, 87.8% and 86.0%. Differences in sensitivity, specificity and accuracy were significant (P < 0.0005). CONCLUSION: DWI showed higher sensitivity and lower specificity than PET/CT. Neither DWI nor PET/CT were sufficiently accurate to replace lymphadenectomy. PMID:22761980

  20. Opacity annotation of diffuse lung diseases using deep convolutional neural network with multi-channel information

    NASA Astrophysics Data System (ADS)

    Mabu, Shingo; Kido, Shoji; Hashimoto, Noriaki; Hirano, Yasushi; Kuremoto, Takashi

    2018-02-01

    This research proposes a multi-channel deep convolutional neural network (DCNN) for computer-aided diagnosis (CAD) that classifies normal and abnormal opacities of diffuse lung diseases in Computed Tomography (CT) images. Because CT images are gray scale, DCNN usually uses one channel for inputting image data. On the other hand, this research uses multi-channel DCNN where each channel corresponds to the original raw image or the images transformed by some preprocessing techniques. In fact, the information obtained only from raw images is limited and some conventional research suggested that preprocessing of images contributes to improving the classification accuracy. Thus, the combination of the original and preprocessed images is expected to show higher accuracy. The proposed method realizes region of interest (ROI)-based opacity annotation. We used lung CT images taken in Yamaguchi University Hospital, Japan, and they are divided into 32 × 32 ROI images. The ROIs contain six kinds of opacities: consolidation, ground-glass opacity (GGO), emphysema, honeycombing, nodular, and normal. The aim of the proposed method is to classify each ROI into one of the six opacities (classes). The DCNN structure is based on VGG network that secured the first and second places in ImageNet ILSVRC-2014. From the experimental results, the classification accuracy of the proposed method was better than the conventional method with single channel, and there was a significant difference between them.

  1. Diffusion-weighted imaging in the evaluation of odontogenic cysts and tumours.

    PubMed

    Srinivasan, K; Seith Bhalla, A; Sharma, R; Kumar, A; Roychoudhury, A; Bhutia, O

    2012-10-01

    The differentiation between keratocystic odontogenic tumour (KCOT) and other cystic/predominantly cystic odontogenic tumours is difficult on conventional CT and MR sequences as there is overlap in the imaging characteristics of these lesions. The purpose of this study was to evaluate the role of diffusion-weighted imaging (DWI) and to assess the performance of apparent diffusion coefficients (ADCs) in the differential diagnosis of odontogenic cysts and tumours. 20 patients with odontogenic cysts and tumours of the maxillomandibular region were examined with DWI. Diffusion-weighted images were obtained with a single-shot echoplanar technique with b-values of 0, 500 and 1000 s mm(-2). An ADC map was obtained at each slice position. The cystic areas of ameloblastoma (n=10) showed free diffusion with a mean ADC value of 2.192±0.33×10(-3) mm(2) s(-1), whereas the solid areas showed restricted diffusion with a mean ADC value of 1.041±0.41×10(-3) mm(2) s(-1). KCOT (n=5) showed restricted diffusion with a mean ADC value of 1.019±0.07×10(-3) mm(2) s(-1). There was a significant difference between the ADC values of KCOT and cystic ameloblastoma (p<0.01, Mann-Whitney U-test). The cut-off with which KCOT and predominantly cystic ameloblastomas were optimally differentiated was 2.013×10(-3) mm(2) s(-1), which yielded 100% sensitivity and 100% specificity. DWI can be used to differentiate KCOT from cystic (or predominantly cystic) odontogenic tumours.

  2. Computerized tomography and pulmonary diffusing capacity in highly trained athletes after performing a triathlon.

    PubMed

    Caillaud, C; Serre-Cousiné, O; Anselme, F; Capdevilla, X; Préfaut, C

    1995-10-01

    We investigated the computerized tomographies (CTs) of the thorax and the pulmonary diffusing capacity for CO (DLCO) in eight male athletes before and after a triathlon. DLCO and alveolar volume (VA) were simultaneously measured during 9 s of breath holding. The transfer coefficient (KCO = DLCO/VA) was then calculated. CT scanning was performed during breath holding with the subjects in the supine position. Scanner analysis was done by 1) counting the linear and polygonal opacities (index of interstitial fluid accumulation) and 2) calculating the physical mean lung density and the mean slice mass. Results showed a significant reduction in DLCO (44.9 +/- 2.3 vs. 42.9 +/- 1.7 ml.min-1.mmHg-1; P < 0.05) and KCO (6.0 +/- 0.3 vs. 5.6 +/- 0.3 ml.min-1.mmHg-1.l of VA-1; P < 0.05) after the triathlon and an increase in mean lung density (0.21 +/- 0.009 vs. 0.25 +/- 0.01 g/cm3; P < 0.0001). The number of polygonal and linear opacities increased after the race (P < 0.001). This study confirmed that DLCO and KCO decrease in elite athletes after a long-distance race and showed a concomitant increase in CT lung density and in the number of opacities.

  3. Hybrid FDG-PET/MR compared to FDG-PET/CT in adult lymphoma patients.

    PubMed

    Atkinson, Wendy; Catana, Ciprian; Abramson, Jeremy S; Arabasz, Grae; McDermott, Shanaugh; Catalano, Onofrio; Muse, Victorine; Blake, Michael A; Barnes, Jeffrey; Shelly, Martin; Hochberg, Ephraim; Rosen, Bruce R; Guimaraes, Alexander R

    2016-07-01

    The goal of this study is to evaluate the diagnostic performance of simultaneous FDG-PET/MR including diffusion compared to FDG-PET/CT in patients with lymphoma. Eighteen patients with a confirmed diagnosis of non-Hodgkin's (NHL) or Hodgkin's lymphoma (HL) underwent an IRB-approved, single-injection/dual-imaging protocol consisting of a clinical FDG-PET/CT and subsequent FDG-PET/MR scan. PET images from both modalities were reconstructed iteratively. Attenuation correction was performed using low-dose CT data for PET/CT and Dixon-MR sequences for PET/MR. Diffusion-weighted imaging was performed. SUVmax was measured and compared between modalities and the apparent diffusion coefficient (ADC) using ROI analysis by an experienced radiologist using OsiriX. Strength of correlation between variables was measured using the Pearson correlation coefficient (r p). Of the 18 patients included in this study, 5 had HL and 13 had NHL. The median age was 51 ± 14.8 years. Sixty-five FDG-avid lesions were identified. All FDG-avid lesions were visible with comparable contrast, and therefore initial and follow-up staging was identical between both examinations. SUVmax from FDG-PET/MR [(mean ± sem) (21.3 ± 2.07)] vs. FDG-PET/CT (mean 23.2 ± 2.8) demonstrated a strongly positive correlation [r s = 0.95 (0.94, 0.99); p < 0.0001]. There was no correlation found between ADCmin and SUVmax from FDG-PET/MR [r = 0.17(-0.07, 0.66); p = 0.09]. FDG-PET/MR offers an equivalent whole-body staging examination as compared with PET/CT with an improved radiation safety profile in lymphoma patients. Correlation of ADC to SUVmax was weak, understating their lack of equivalence, but not undermining their potential synergy and differing importance.

  4. Computed tomographic features of idiopathic fibrosing interstitial pneumonia: comparison with pulmonary fibrosis related to collagen vascular disease.

    PubMed

    Hwang, Jeong-Hwa; Misumi, Shigeki; Sahin, Hakan; Brown, Kevin K; Newell, John D; Lynch, David A

    2009-01-01

    To compare the computed tomographic (CT) features of idiopathic fibrosing interstitial pneumonia with those of pulmonary fibrosis related to collagen vascular disease (CVD). We reviewed the CT scans of 177 patients with diffuse interstitial pulmonary fibrosis, of which 97 had idiopathic fibrosing interstitial pneumonia and 80 had CVD. The CT images were systematically scored for the presence and extent of pulmonary and extrapulmonary abnormalities. Computed tomographic diagnosis of usual interstitial pneumonia (UIP) or nonspecific interstitial pneumonia (NSIP) was assigned. A CT pattern of UIP was identified in 59 (60.8%) of patients with idiopathic fibrosing interstitial pneumonia compared with 15 (18.7%) of those patients with CVD; conversely, the CT diagnosis of NSIP was made in 51 (64%) of patients with CVD compared with 36 (37%) of patients with idiopathic disease (P < 0.01). In 113 patients who had lung biopsy, the CT diagnoses of UIP and NSIP were concordant with the histologic diagnoses in 36 of 50 patients and 34 of 41 patients, respectively. Pleural effusions, esophageal dilation, and pericardial abnormalities were more frequent in patients with CVD than in patients with idiopathic fibrosing interstitial pneumonia. Compared with patients with CVD, those patients with an idiopathic fibrosing interstitial pneumonia showed a higher prevalence of a UIP pattern and lower prevalence of an NSIP pattern as determined by CT. Identification of coexisting extrapulmonary abnormalities on CT can support a diagnosis of CVD.

  5. Principal component analysis of the CT density histogram to generate parametric response maps of COPD

    NASA Astrophysics Data System (ADS)

    Zha, N.; Capaldi, D. P. I.; Pike, D.; McCormack, D. G.; Cunningham, I. A.; Parraga, G.

    2015-03-01

    Pulmonary x-ray computed tomography (CT) may be used to characterize emphysema and airways disease in patients with chronic obstructive pulmonary disease (COPD). One analysis approach - parametric response mapping (PMR) utilizes registered inspiratory and expiratory CT image volumes and CT-density-histogram thresholds, but there is no consensus regarding the threshold values used, or their clinical meaning. Principal-component-analysis (PCA) of the CT density histogram can be exploited to quantify emphysema using data-driven CT-density-histogram thresholds. Thus, the objective of this proof-of-concept demonstration was to develop a PRM approach using PCA-derived thresholds in COPD patients and ex-smokers without airflow limitation. Methods: Fifteen COPD ex-smokers and 5 normal ex-smokers were evaluated. Thoracic CT images were also acquired at full inspiration and full expiration and these images were non-rigidly co-registered. PCA was performed for the CT density histograms, from which the components with the highest eigenvalues greater than one were summed. Since the values of the principal component curve correlate directly with the variability in the sample, the maximum and minimum points on the curve were used as threshold values for the PCA-adjusted PRM technique. Results: A significant correlation was determined between conventional and PCA-adjusted PRM with 3He MRI apparent diffusion coefficient (p<0.001), with CT RA950 (p<0.0001), as well as with 3He MRI ventilation defect percent, a measurement of both small airways disease (p=0.049 and p=0.06, respectively) and emphysema (p=0.02). Conclusions: PRM generated using PCA thresholds of the CT density histogram showed significant correlations with CT and 3He MRI measurements of emphysema, but not airways disease.

  6. Fusion of Computed Tomography and PROPELLER Diffusion-Weighted Magnetic Resonance Imaging for the Detection and Localization of Middle Ear Cholesteatoma.

    PubMed

    Locketz, Garrett D; Li, Peter M M C; Fischbein, Nancy J; Holdsworth, Samantha J; Blevins, Nikolas H

    2016-10-01

    A method to optimize imaging of cholesteatoma by combining the strengths of available modalities will improve diagnostic accuracy and help to target treatment. To assess whether fusing Periodically Rotated Overlapping Parallel Lines With Enhanced Reconstruction (PROPELLER) diffusion-weighted magnetic resonance imaging (DW-MRI) with corresponding temporal bone computed tomography (CT) images could increase cholesteatoma diagnostic and localization accuracy across 6 distinct anatomical regions of the temporal bone. Case series and preliminary technology evaluation of adults with preoperative temporal bone CT and PROPELLER DW-MRI scans who underwent surgery for clinically suggested cholesteatoma at a tertiary academic hospital. When cholesteatoma was encountered surgically, the precise location was recorded in a diagram of the middle ear and mastoid. For each patient, the 3 image data sets (CT, PROPELLER DW-MRI, and CT-MRI fusion) were reviewed in random order for the presence or absence of cholesteatoma by an investigator blinded to operative findings. If cholesteatoma was deemed present on review of each imaging modality, the location of the lesion was mapped presumptively. Image analysis was then compared with surgical findings. Twelve adults (5 women and 7 men; median [range] age, 45.5 [19-77] years) were included. The use of CT-MRI fusion had greater diagnostic sensitivity (0.88 vs 0.75), positive predictive value (0.88 vs 0.86), and negative predictive value (0.75 vs 0.60) than PROPELLER DW-MRI alone. Image fusion also showed increased overall localization accuracy when stratified across 6 distinct anatomical regions of the temporal bone (localization sensitivity and specificity, 0.76 and 0.98 for CT-MRI fusion vs 0.58 and 0.98 for PROPELLER DW-MRI). For PROPELLER DW-MRI, there were 15 true-positive, 45 true-negative, 1 false-positive, and 11 false-negative results; overall accuracy was 0.83. For CT-MRI fusion, there were 20 true-positive, 45 true-negative, 1 false-positive, and 6 false-negative results; overall accuracy was 0.90. The poor anatomical spatial resolution of DW-MRI makes precise localization of cholesteatoma within the middle ear and mastoid a diagnostic challenge. This study suggests that the bony anatomic detail obtained via CT coupled with the excellent sensitivity and specificity of PROPELLER DW-MRI for cholesteatoma can improve both preoperative identification and localization of disease over DW-MRI alone.

  7. Robust segmentation of trabecular bone for in vivo CT imaging using anisotropic diffusion and multi-scale morphological reconstruction

    NASA Astrophysics Data System (ADS)

    Chen, Cheng; Jin, Dakai; Zhang, Xiaoliu; Levy, Steven M.; Saha, Punam K.

    2017-03-01

    Osteoporosis is associated with an increased risk of low-trauma fractures. Segmentation of trabecular bone (TB) is essential to assess TB microstructure, which is a key determinant of bone strength and fracture risk. Here, we present a new method for TB segmentation for in vivo CT imaging. The method uses Hessian matrix-guided anisotropic diffusion to improve local separability of trabecular structures, followed by a new multi-scale morphological reconstruction algorithm for TB segmentation. High sensitivity (0.93), specificity (0.93), and accuracy (0.92) were observed for the new method based on regional manual thresholding on in vivo CT images. Mechanical tests have shown that TB segmentation using the new method improved the ability of derived TB spacing measure for predicting actual bone strength (R2=0.83).

  8. Ultrasound findings of diffuse metastasis of gastric signet-ring-cell carcinoma to the thyroid gland.

    PubMed

    Morita, Koji; Sakamoto, Takahiko; Ota, Shuji; Masugi, Hideo; Chikuta, Ikumi; Mashimo, Yamato; Edo, Naoki; Tokairin, Takuo; Seki, Nobuhiko; Ishikawa, Toshio

    2017-01-01

    It has been shown that metastases to the thyroid from extrathyroidal malignancies occur as solitary or multiple nodules, or may involve the whole thyroid gland diffusely. However, diffuse metastasis of gastric cancer to the thyroid is extremely rare. Here, we report a case of a 74-year-old woman with diffuse infiltration of gastric adenocarcinoma (signet-ring-cell carcinoma/poorly differentiated adenocarcinoma) cells in the thyroid. The pathological diagnosis was made based on upper gastrointestinal endoscopy with biopsy and fine-needle aspiration cytology of the thyroid. An 18F-FDG PET/CT revealed multiple lesions with increased uptake, including the bilateral thyroid gland. On thyroid ultrasound examination, diffuse enlargement with internal heterogeneity and hypoechoic reticular lines was observed. On color Doppler imaging, a blood-flow signal was not detected in these hypoechoic lines. These findings were similar to those of diffuse metastases caused by other primary cancers, such as lung cancer, as reported earlier. Therefore, the presence of hypoechoic reticular lines without blood-flow signals is probably common to diffuse thyroid metastasis from any origin and an important diagnostic finding. This is the first report to show detailed ultrasound findings of diffuse gastric cancer metastasis to the thyroid gland using color Doppler.

  9. Diffusion processes in tumors: A nuclear medicine approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amaya, Helman, E-mail: haamayae@unal.edu.co

    The number of counts used in nuclear medicine imaging techniques, only provides physical information about the desintegration of the nucleus present in the the radiotracer molecules that were uptaken in a particular anatomical region, but that information is not a real metabolic information. For this reason a mathematical method was used to find a correlation between number of counts and {sup 18}F-FDG mass concentration. This correlation allows a better interpretation of the results obtained in the study of diffusive processes in an agar phantom, and based on it, an image from the PETCETIX DICOM sample image set from OsiriX-viewer softwaremore » was processed. PET-CT gradient magnitude and Laplacian images could show direct information on diffusive processes for radiopharmaceuticals that enter into the cells by simple diffusion. In the case of the radiopharmaceutical {sup 18}F-FDG is necessary to include pharmacokinetic models, to make a correct interpretation of the gradient magnitude and Laplacian of counts images.« less

  10. 68Ga-NODAGA-RGDyK PET/CT Imaging in Esophageal Cancer: First-in-Human Imaging.

    PubMed

    Van Der Gucht, Axel; Pomoni, Anastasia; Jreige, Mario; Allemann, Pierre; Prior, John O

    2016-11-01

    Ga-NODAGA-RGDyK(cyclic) and FDG PET/CT were performed in a 39-year-old man for the work-up of a moderately differentiated carcinoma of the gastro-esophageal junction within a clinical study protocol. Although FDG PET images showed intense, diffuse hypermetabolic lesion activity, NODAGA-RGDyK illustrated the neo-angiogenesis process with tracer uptake clearly localized in non-FDG-avid perilesional structures. Neo-angiogenesis is characterized by ανβ3 integrin expression at the lesion surface of newly formed vessels. This case supports evidence that angiogenesis imaging might therefore be a crucial step in early disease identification and localization, metastatization potential, and in monitoring the efficacy of antiangiogenic therapies.

  11. Sarcoidosis with Pancreatic Mass, Endobronchial Nodules, and Miliary Opacities in the Lung.

    PubMed

    Matsuura, Shun; Mochizuka, Yasutaka; Oishi, Kyohei; Miyashita, Koichi; Naoi, Hyogo; Mochizuki, Eisuke; Mikura, Shinichiro; Tsukui, Masaru; Koshimizu, Naoki; Ohata, Akihiko; Suda, Takahumi

    2017-11-15

    Sarcoidosis affects multiple organs and rarely has unusual manifestations. A 78-year-old woman was referred to our hospital for coughing symptoms. A chest computed tomography (CT) scan revealed bilateral diffuse miliary patterns and right pleural effusion. Bronchoscopy showed multiple nodules in the carina and the bronchus intermedius. A CT scan of her abdomen revealed hypovascular lesions involving the pancreatic head and body. A transbronchial lung biopsy, bronchial mucosal biopsy, and endoscopic ultrasound-guided fine-needle aspiration of the pancreatic mass demonstrated non-caseating granulomas. We diagnosed the patient with sarcoidosis. She received no treatment for sarcoidosis and has been followed up for one year, during which no pulmonary disease progression had been observed and the pancreatic masses partially regressed.

  12. Lung diffusing capacity for nitric oxide as a marker of fibrotic changes in idiopathic interstitial pneumonias.

    PubMed

    Barisione, Giovanni; Brusasco, Claudia; Garlaschi, Alessandro; Baroffio, Michele; Brusasco, Vito

    2016-05-01

    Lung diffusing capacity for carbon monoxide (DLCO) is decreased in both usual interstitial pneumonia-idiopathic pulmonary fibrosis (UIP-IPF) and nonspecific interstitial pneumonia (NSIP), but is moderately related to computed tomography (CT)-determined fibrotic changes. This may be due to the relative insensitivity of DLCO to changes in alveolar membrane diffusive conductance (DMCO). The purpose of this study was to determine whether measurement of lung diffusing capacity for nitric oxide (DLNO) better reflects fibrotic changes than DLCO DLNO-DLCO were measured simultaneously in 30 patients with UIP-IPF and 30 with NSIP. Eighty-one matched healthy subjects served as a control group. The amount of pulmonary fibrosis was estimated by CT volumetric analysis of visually bounded areas showing reticular opacities and honeycombing. DMCO and pulmonary capillary volume (VC) were calculated. DLNO was below the lower limit of normal in all patients irrespective of extent and nature of disease, whereas DLCO was within the normal range in a nonnegligible number of patients. Both DLNO and DLCO were significantly correlated with visual assessment of fibrosis but DLNO more closely than DLCO DMCO was also below the lower limit of normal in all UIP-IPF and NSIP patients and significantly correlated with fibrosis extent in both diseases, whereas VC was weakly correlated with fibrosis in UIP-IPF and uncorrelated in NSIP, with normal values in half of patients. In conclusion, measurement of DLNO may provide a more sensitive evaluation of fibrotic changes than DLCO in either UIP-IPF or NSIP, because it better reflects DMCO. Copyright © 2016 the American Physiological Society.

  13. Ewing's Sarcoma of the Peritoneum: a Rare Location for Extraskeletal Ewing's Sarcoma.

    PubMed

    Saglam, Muzaffer; Ozdemir, Yavuz; Yigit, Taner; Kucukodaci, Zafer; Sonmez, Guner

    2016-11-01

    A 38-year-old male presented to the emergency department with abdominal pain and bulge. He had a history of irritable bowel syndrome for 1 year with complaint of dyspepsia. Physical examination revealed a distended abdomen with a huge palpable mass located in the paraumblical region. Laboratory findings revealed a high white blood cell count with neutrophil predominance. Contrast-enhanced computed tomography (CT) showed a 23-cm, oval-shaped, grossly necrotic, low-attenuation mass with peripherally located dominant vessels. Magnetic resonance imaging (MRI) with diffusion weighted imaging (DWI) suggested a highly malignant tumor with prominent diffusion restriction especially at the periphery of the mass. On surgery, macroscopic examination showed a macrolobulated, hypervascular, reddish brown mass attached to the parietal peritoneum with a stalk. Ewing's sarcoma (ES) was diagnosed on histopathological examination with small round cells.

  14. [Cavernous sinus thrombosis as a rare cause of exophthalmos in childhood : A case report].

    PubMed

    Kamawal, A; Schmidt, M A; Rompel, O; Gusek-Schneider, G C; Mardin, C Y; Trollmann, R

    2017-05-01

    Complications of acute bacterial sinusitis mostly occur in children and adolescents. In particular, intracranial spread of the infection can lead to severe even fatal courses of the disease. This article is a case report about a 13-year-old boy suffering from left-sided headache, meningismus and exophthalmos as presenting symptoms. Cranial magnetic resonance imaging (MRI) showed merely right-sided sphenoid sinusitis; however, the diffusion-weighted MRI sequence indicated a left-sided cavernous sinus thrombosis, which could be confirmed by computed tomography (CT) angiography. Cerebrospinal fluid diagnostics showed significant leukocytosis confirming secondary meningitis. Finally, exophthalmos was explained by parainfectious cavernous sinus thrombosis and periorbital edema. This case report highlights the importance of extended and specific diagnostic imaging in cases of clinically suspected complications in children and adolescents with sinusitis and the diagnostic significance of diffusion-weighted MRI.

  15. FDG-PET/CT and diffusion-weighted imaging for resected lung cancer: correlation of maximum standardized uptake value and apparent diffusion coefficient value with prognostic factors.

    PubMed

    Usuda, Katsuo; Funasaki, Aika; Sekimura, Atsushi; Motono, Nozomu; Matoba, Munetaka; Doai, Mariko; Yamada, Sohsuke; Ueda, Yoshimichi; Uramoto, Hidetaka

    2018-04-09

    Diffusion-weighted magnetic resonance imaging (DWI) is useful for detecting malignant tumors and the assessment of lymph nodes, as FDG-PET/CT is. But it is not clear how DWI influences the prognosis of lung cancer patients. The focus of this study is to evaluate the correlations between maximum standardized uptake value (SUVmax) of FDG-PET/CT and apparent diffusion coefficient (ADC) value of DWI with known prognostic factors in resected lung cancer. A total of 227 patients with resected lung cancers were enrolled in this study. FEG-PET/CT and DWI were performed in each patient before surgery. There were 168 patients with adenocarcinoma, 44 patients with squamous cell carcinoma, and 15 patients with other cell types. SUVmax was a factor that was correlated to T factor, N factor, or cell differentiation. ADC of lung cancer was a factor that was not correlated to T factor, or N factor. There was a significantly weak inverse relationship between SUVmax and ADC (Correlation coefficient r = - 0.227). In analysis of survival, there were significant differences between the categories of sex, age, pT factor, pN factor, cell differentiation, cell type, and SUVmax. Univariate analysis revealed that SUVmax, pN factor, age, cell differentiation, cell type, sex, and pT factor were significant factors. Multivariate analysis revealed that SUVmax and pN factor were independent significant prognostic factors. SUVmax was a significant prognostic factor that is correlated to T factor, N factor, or cell differentiation, but ADC was not. SUVmax may be more useful for predicting the prognosis of lung cancer than ADC values.

  16. Study of Safety,Efficacy and Pharmacokinetics of CT-1530 in Patients With Relapsed or Refractory B Cell Non-Hodgkin Lymphoma, Chronic Lymphocytic Leukemia, and Waldenstrom's Macroglobulinemia

    ClinicalTrials.gov

    2017-07-18

    Relapsed or Refractory B Cell Non-Hodgkin Lymphoma; Chronic Lymphocytic Leukemia; Waldenstrom's Macroglobulinemia; Mantle Zone Lymphoma Refractory/Recurrent; Follicle Centre Lymphoma Diffuse; Diffuse Large B Cell Lymphoma

  17. Modeling Cryptosporidium spp. Oocyst Inactivation in Bubble-Diffuser Ozone Contactors

    DTIC Science & Technology

    1998-07-01

    requirements for Giardia lamblia (G. lamblia) and viruses under the Surface Water Treatment Rule (SWTR). Minimum CT requirements include relatively...parvum and C. muris ) oocysts in ozone bubble-diffuser contactors. The model is calibrated with semi-batch kinetic data, verified with pilot-scale

  18. Ensemble Classification of Alzheimer's Disease and Mild Cognitive Impairment Based on Complex Graph Measures from Diffusion Tensor Images

    PubMed Central

    Ebadi, Ashkan; Dalboni da Rocha, Josué L.; Nagaraju, Dushyanth B.; Tovar-Moll, Fernanda; Bramati, Ivanei; Coutinho, Gabriel; Sitaram, Ranganatha; Rashidi, Parisa

    2017-01-01

    The human brain is a complex network of interacting regions. The gray matter regions of brain are interconnected by white matter tracts, together forming one integrative complex network. In this article, we report our investigation about the potential of applying brain connectivity patterns as an aid in diagnosing Alzheimer's disease and Mild Cognitive Impairment (MCI). We performed pattern analysis of graph theoretical measures derived from Diffusion Tensor Imaging (DTI) data representing structural brain networks of 45 subjects, consisting of 15 patients of Alzheimer's disease (AD), 15 patients of MCI, and 15 healthy subjects (CT). We considered pair-wise class combinations of subjects, defining three separate classification tasks, i.e., AD-CT, AD-MCI, and CT-MCI, and used an ensemble classification module to perform the classification tasks. Our ensemble framework with feature selection shows a promising performance with classification accuracy of 83.3% for AD vs. MCI, 80% for AD vs. CT, and 70% for MCI vs. CT. Moreover, our findings suggest that AD can be related to graph measures abnormalities at Brodmann areas in the sensorimotor cortex and piriform cortex. In this way, node redundancy coefficient and load centrality in the primary motor cortex were recognized as good indicators of AD in contrast to MCI. In general, load centrality, betweenness centrality, and closeness centrality were found to be the most relevant network measures, as they were the top identified features at different nodes. The present study can be regarded as a “proof of concept” about a procedure for the classification of MRI markers between AD dementia, MCI, and normal old individuals, due to the small and not well-defined groups of AD and MCI patients. Future studies with larger samples of subjects and more sophisticated patient exclusion criteria are necessary toward the development of a more precise technique for clinical diagnosis. PMID:28293162

  19. Gossypiboma Mimicking Gastrointestinal Stromal Tumor Causing Intestinal Obstruction: A Case Report

    PubMed Central

    Kawamura, Yurika; Ogasawara, Naotaka; Yamamoto, Sayuri; Sasaki, Makoto; Kawamura, Naohiko; Izawa, Shinya; Kobayashi, Yuji; Kamei, Seiji; Miyachi, Masahiko; Kasugai, Kunio

    2012-01-01

    A 41-year-old woman was admitted to our hospital with abdominal pain that developed about 1 year after a Cesarean section. Pelvic computed tomography (CT) revealed diffuse dilation of the small intestine with fluid shadows and a pelvic tumor 55 mm in diameter. The density of the tumor, which was not enhanced by intravenous contrast medium, was diffuse and similar to that of muscular tissue, whereas the density of a capsule surrounding the mass was relatively high. T1- and T2-weighted pelvic magnetic resonance imaging (MRI) of the tumor revealed the same diffuse low-intensity signals as muscular tissue, and diffuse high-intensity signals, respectively. The CT and MRI findings were consistent with those of a gastrointestinal stromal tumor (GIST) causing ileus of the small intestine. As inserting an ileus tube did not improve her symptoms, the patient was scheduled for tumor resection. The operative findings revealed a hard, solid tumor adhering to the surrounding small intestine. The macroscopic findings revealed that the tumor consisted of layers of stratified gauze surrounded by a thick granulomatous wall. The gossypiboma was considered to have originated from gauze that had been left behind after the Cesarean section. If a patient has a history of surgery, the possibility of gossypiboma should be considered when CT or MRI findings indicate features of GIST. PMID:22679410

  20. Unified heat kernel regression for diffusion, kernel smoothing and wavelets on manifolds and its application to mandible growth modeling in CT images.

    PubMed

    Chung, Moo K; Qiu, Anqi; Seo, Seongho; Vorperian, Houri K

    2015-05-01

    We present a novel kernel regression framework for smoothing scalar surface data using the Laplace-Beltrami eigenfunctions. Starting with the heat kernel constructed from the eigenfunctions, we formulate a new bivariate kernel regression framework as a weighted eigenfunction expansion with the heat kernel as the weights. The new kernel method is mathematically equivalent to isotropic heat diffusion, kernel smoothing and recently popular diffusion wavelets. The numerical implementation is validated on a unit sphere using spherical harmonics. As an illustration, the method is applied to characterize the localized growth pattern of mandible surfaces obtained in CT images between ages 0 and 20 by regressing the length of displacement vectors with respect to a surface template. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. [A case of severe asthma exacerbation complicated with cerebral edema and diffuse multiple cerebral micro-bleeds].

    PubMed

    Ohkura, Noriyuki; Fujimura, Masaki; Sakai, Asao; Fujita, Kentaro; Katayama, Nobuyuki

    2009-08-01

    A 36-year-old woman was admitted to the Intensive Care Unit for the treatment of severe asthma exacerbation. Her condition of asthma improved with systemic glucocorticosteroids, inhaled beta2-agonist, intravenous theophylline and inhaled anesthesia (isoflurane) under mechanical ventilation. Her consciousness was disturbed even after terminating isoflurane. Brain CT and MRI scan showed cerebral edema and diffuse multiple cerebral micro-bleeds. Glyceol, a hyperosmotic diuretic solution consisting of 10% glycerol and 5% fructose in saline, was administered to decrease cerebral edema. Her consciousness disturbance gradually recovered. Cerebral edema and hemorrhage improved. On the 69th hospital day, she was discharged from hospital without sequelae. This case is a rare one in which severe asthma exacerbation was complicated with cerebral edema and diffuse multiple cerebral hemorrhage. Inhaled anesthesia for asthma exacerbation should be used carefully to avoid delay of diagnosis of central nervous system complications.

  2. Antisynthetase syndrome (ASS) presenting as acute respiratory distress syndrome (ARDS) in a patient without myositis features.

    PubMed

    Kanchustambham, Venkat Kiran; Saladi, Swetha; Mahmoudassaf, Sarah; Patolia, Setu

    2016-12-09

    A woman aged 61 years presented to the emergency room with a 1-week history of dyspnoea on exertion and dry cough. X-ray of the chest showed diffuse interstitial opacities and was started on antibiotics and furosemide, and despite these measures, patient's respiratory status worsened, prompting endotracheal intubation. CT of the chest showed diffuse bilateral ground glass opacities and underwent bronchoscope with trans-bronchial biopsy that showed chronic bronchitis. Pt was empirically started on intravenous steroids due to concerns for interstitial lung disease (ILD). Autoimmune work up was sent and underwent video-assisted thoracoscopic surgery-guided biopsy of the lung that showed non-specific interstitial pattern with fibrosis. The patient was diagnosed as having antisynthetase syndrome with pulmonary involvement (ILD) as the cause of her acute respiratory failure. Azathioprine was started as steroid-sparing agent and was weaned off the ventilator to a tracheostomy collar and discharged to long-term rehabilitation centre. 2016 BMJ Publishing Group Ltd.

  3. Contractile properties of rat skeletal muscles following storage at 4 degrees C.

    PubMed

    van der Heijden, E P; Kroese, A B; Stremel, R W; Bär, P R; Kon, M; Werker, P M

    1999-07-01

    The purpose of this study was to assess the potential of preservation solutions for protecting skeletal muscle function during storage at 4 degrees C. The soleus and the cutaneus trunci (CT) from the rat were stored for 2, 8 or 16 h at 4 degrees C in University of Wisconsin solution (UW), HTK-Bretschneider solution (HTK) or Krebs-Henseleit solution (KH). After storage, muscles were stimulated electrically to analyse the isometric contractile properties, such as the maximum tetanic tension (P(0)). Histological analysis was also performed. In separate experiments, the effect of the diffusion distance on muscle preservation was studied by bisecting the soleus. After 8 h of storage in UW or HTK, the contractile properties of the CT were similar to those of the control, whereas those of the soleus were reduced (P(0) values of 16% and 69% of control in UW and HTK respectively). At 16 h, the contractile properties of the CT (P(O) 28%) were again better preserved than those of the soleus (P(0) 9%). Muscle function deteriorated most after storage in KH (P(0) at 16 h: soleus, 3%; CT, 17%). The bisected soleus was equally well preserved as the CT (P(O) of bisected soleus at 8 h in UW and HTK: 86%). The functional data corresponded well with the histological data, which showed increasing muscle fibre derangement with increasing storage time. For both muscles and all solutions, the threshold stimulus current increased with increasing storage time (control, 0.1 mA; 16 h, 1.2 mA) and was strongly correlated with the deterioration in contractile properties. It is concluded that, at 4 degrees C, muscle is preserved better in UW and HTK (intracellular-like solutions) than in KH (extracellular-like solution). The soleus and CT were best protected in HTK. The diffusion distance is a critical factor for successful preservation of muscle function at 4 degrees C. The reduced function after 16 h of storage at 4 degrees C was caused by hypercontraction and necrosis of about 25% of the muscle fibres, and by deterioration of the electrical component of excitation-contraction coupling of the remaining fibres.

  4. Hyperspectral optical tomography of intrinsic signals in the rat cortex

    PubMed Central

    Konecky, Soren D.; Wilson, Robert H.; Hagen, Nathan; Mazhar, Amaan; Tkaczyk, Tomasz S.; Frostig, Ron D.; Tromberg, Bruce J.

    2015-01-01

    Abstract. We introduce a tomographic approach for three-dimensional imaging of evoked hemodynamic activity, using broadband illumination and diffuse optical tomography (DOT) image reconstruction. Changes in diffuse reflectance in the rat somatosensory cortex due to stimulation of a single whisker were imaged at a frame rate of 5 Hz using a hyperspectral image mapping spectrometer. In each frame, images in 38 wavelength bands from 484 to 652 nm were acquired simultaneously. For data analysis, we developed a hyperspectral DOT algorithm that used the Rytov approximation to quantify changes in tissue concentration of oxyhemoglobin (ctHbO2) and deoxyhemoglobin (ctHb) in three dimensions. Using this algorithm, the maximum changes in ctHbO2 and ctHb were found to occur at 0.29±0.02 and 0.66±0.04  mm beneath the surface of the cortex, respectively. Rytov tomographic reconstructions revealed maximal spatially localized increases and decreases in ctHbO2 and ctHb of 321±53 and 555±96  nM, respectively, with these maximum changes occurring at 4±0.2  s poststimulus. The localized optical signals from the Rytov approximation were greater than those from modified Beer–Lambert, likely due in part to the inability of planar reflectance to account for partial volume effects. PMID:26835483

  5. TBIdoc: 3D content-based CT image retrieval system for traumatic brain injury

    NASA Astrophysics Data System (ADS)

    Li, Shimiao; Gong, Tianxia; Wang, Jie; Liu, Ruizhe; Tan, Chew Lim; Leong, Tze Yun; Pang, Boon Chuan; Lim, C. C. Tchoyoson; Lee, Cheng Kiang; Tian, Qi; Zhang, Zhuo

    2010-03-01

    Traumatic brain injury (TBI) is a major cause of death and disability. Computed Tomography (CT) scan is widely used in the diagnosis of TBI. Nowadays, large amount of TBI CT data is stacked in the hospital radiology department. Such data and the associated patient information contain valuable information for clinical diagnosis and outcome prediction. However, current hospital database system does not provide an efficient and intuitive tool for doctors to search out cases relevant to the current study case. In this paper, we present the TBIdoc system: a content-based image retrieval (CBIR) system which works on the TBI CT images. In this web-based system, user can query by uploading CT image slices from one study, retrieval result is a list of TBI cases ranked according to their 3D visual similarity to the query case. Specifically, cases of TBI CT images often present diffuse or focal lesions. In TBIdoc system, these pathological image features are represented as bin-based binary feature vectors. We use the Jaccard-Needham measure as the similarity measurement. Based on these, we propose a 3D similarity measure for computing the similarity score between two series of CT slices. nDCG is used to evaluate the system performance, which shows the system produces satisfactory retrieval results. The system is expected to improve the current hospital data management in TBI and to give better support for the clinical decision-making process. It may also contribute to the computer-aided education in TBI.

  6. Specific Heat and Thermal Diffusivity of YBCO Coated Conductors

    NASA Astrophysics Data System (ADS)

    Naito, Tomoyuki; Fujishiro, Hiroyuki; YasuhisaYamamura; Saito, Kazuya; Okamoto, Hiroshi; Hayashi, Hidemi; Gosho, Yoshihiro; Ohkuma, Takeshi; Shiohara, Yuh

    We have measured the temperature dependence of specific heat,C(T), for Ag deposited YBCO coated conductor (YCC),YCC reinforced by a thin Cutape (YCC-Cu), andthe Hastelloy substrate with buffer layer. C(T) of HastelloyC-276 with buffer layer agrees well with the reported oneof HastelloyC-276, indicating that the contribution of the buffer layer to the measured C(T) is negligibly small. C(T)of both YCC and YCC-Cu tapes was successfully reproduced by the simple sum rule using the C(T) values reported for Hastelloy, Ag and Cu. The results demonstrate that C(T) of various YCC tapes can be estimated using the reported C(T)of constitutional materials. The estimated thermal diffusivity, a = K/C, at 300K of YCC, which was estimated using the thermal conductivity, K, did not agree with the reported a of Ag. This resultwas in consistent with the fact that the applied heat flew through the Aglayer, suggesting that a relation of a = K/Cfor homogeneous material cannot be applicable for the layered material such as YCC.

  7. Improved quantitative recovery of Listeria monocytogenes from stainless steel surfaces using a one-ply composite tissue.

    PubMed

    Vorst, Keith L; Todd, Ewen C D; Rysert, Elliot T

    2004-10-01

    Four sampling devices, a sterile environmental sponge (ES), a sterile cotton-tipped swab (CS), a sterile calcium alginate fiber-tipped swab (CAS), and a one-ply composite tissue (CT), were evaluated for quantitative recovery of Listeria monocytogenes from a food-grade stainless steel surface. Sterile 304-grade stainless steel plates (6 by 6 cm) were inoculated with approximately 106 CFU/cm2 L. monocytogenes strain Scott A and dried for 1 h. The ES and CT sampling devices were rehydrated in phosphate buffer solution. After plate swabbing, ES and CT were placed in 40 ml of phosphate buffer solution, stomached for 1 min and hand massaged for 30 s. Each CS and CAS device was rehydrated in 0.1% peptone before swabbing. After swabbing, CS and CAS were vortexed in 0.1% peptone for 1 min. Samples were spiral plated on modified Oxford agar with modified Oxford agar Rodac Contact plates used to recover any remaining cells from the stainless steel surface. Potential inhibition from CT was examined in both phosphate buffer solution and in a modified disc-diffusion assay. Recovery was 2.70, 1.34, and 0.62 log greater using CT compared with ES, CS, and CAS, respectively, with these differences statistically significant (P < 0.001) for ES and CT and for CAS, CS, and CT (P < 0.05). Rodac plates were typically overgrown following ES, positive after CS and CAS, and negative after CT sampling. CT was noninhibitory in both phosphate buffer solution and the modified disc-diffusion assay. Using scanning electron microscopy, Listeria cells were observed on stainless steel plates sampled with each sampling device except CT. The CT device, which is inexpensive and easy to use, represents a major improvement over other methods in quantifying L. monocytogenes on stainless steel surfaces and is likely applicable to enrichment of environmental samples.

  8. Non-invasive three-dimensional imaging of Escherichia coli K1 infection using diffuse light imaging tomography combined with micro-computed tomography.

    PubMed

    Witcomb, Luci A; Czupryna, Julie; Francis, Kevin P; Frankel, Gad; Taylor, Peter W

    2017-08-15

    In contrast to two-dimensional bioluminescence imaging, three dimensional diffuse light imaging tomography with integrated micro-computed tomography (DLIT-μCT) has the potential to realise spatial variations in infection patterns when imaging experimental animals dosed with derivatives of virulent bacteria carrying bioluminescent reporter genes such as the lux operon from the bacterium Photorhabdus luminescens. The method provides an opportunity to precisely localise the bacterial infection sites within the animal and enables the generation of four-dimensional movies of the infection cycle. Here, we describe the use of the PerkinElmer IVIS SpectrumCT in vivo imaging system to investigate progression of lethal systemic infection in neonatal rats following colonisation of the gastrointestinal tract with the neonatal pathogen Escherichia coli K1. We confirm previous observations that these bacteria stably colonize the colon and small intestine following feeding of the infectious dose from a micropipette; invading bacteria migrate across the gut epithelium into the blood circulation and establish foci of infection in major organs, including the brain. DLIT-μCT revealed novel multiple sites of colonisation within the alimentary canal, including the tongue, oesophagus and stomach, with penetration of the non-keratinised oesophageal epithelial surface, providing strong evidence of a further major site for bacterial dissemination. We highlight technical issues associated with imaging of infections in new born rat pups and show that the whole-body and organ bioburden correlates with disease severity. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Value of apparent diffusion coefficient (ADC) in assessing radiotherapy and chemotherapy success in cervical cancer.

    PubMed

    Fu, Zhan-Zhao; Peng, Yong; Cao, Li-Yan; Chen, Yan-Sheng; Li, Kun; Fu, Bao-Hong

    2015-06-01

    We investigated the clinical significance of apparent diffusion coefficient (ADC) values in diffusion-weighted magnetic resonance imaging (DWI) in monitoring the efficacy of radiotherapy (RT) and chemotherapy (CT) treatments in cervical cancer. In order to identify relevant high quality clinical cohort studies reporting the use of DWI in cervical cancers, the following electronic databases in English and Chinese languages were comprehensively searched: MEDLINE, Science Citation Index database, Cochrane Library Database, PubMed, Embase, CINAHL, and Current Contents Index; Chinese Biomedical Database, Chinese Journal Full-Text Database. All selected studies were published prior to March 2014, and data extracted from these studies were analyzed using STATA 12.0 statistical software. We initially retrieved 196 articles (79 Chinese articles and 117 English articles) through database searches and finally selected sixteen cohort studies for this meta-analysis. The 16 studies contained a combined total of 517 subjects, and all selected studies reported the mean ADC value (10(-3) mm(2)/s) in DWI in cervical cancer patients treated with RT and CT. Combined standardized mean difference (SMD) suggested that the mean post-RT and mean post-CT ADC values were significantly higher than the mean pre-RT and mean pre-CT ADC values, respectively, in cervical cancer patients (SMD=2.95, 95% CI=2.19-3.72, P<0.001). Ethnicity-stratified analysis revealed that increased ADC values were observed post-RT and post-CT in both Caucasian (SMD=1.44, 95% CI=0.93-1.95, P<0.001) and Asian populations (SMD=3.32, 95% CI=2.42-4.22, P<0.001), compared with the mean ADC values before RT and CT, respectively, in the two subgroups. Further, subgroup analysis based on b-value revealed that higher ADC values were found in cervical cancer patients after RT and CT, compared to before RT and CT treatment, with both b value≤900 (SMD=3.71, 95% CI=2.35-5.07, P<0.001) and >900 (SMD=2.55, 95% CI=1.78-3.32, P<0.001). The mean ADC value in patients without residual tumor post-RT and post-CT treatment was significantly higher than seen in patients with residual tumors (SMD=0.80, 95% CI=0.49-1.12, P<0.001). Our meta-analysis revealed a significant correlation between mean ADC values and the clinical response to RT and CT treatment. Thus, ADC values in DWI may be effective in evaluating the clinical outcome of treatments in cervical cancer patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Fatal pleural mesothelioma in Japan (2003-2008): evaluation of computed tomography findings.

    PubMed

    Kato, Katsuya; Gemba, Kenichi; Fujimoto, Nobukazu; Aoe, Keisuke; Takeshima, Yukio; Inai, Kouki; Kishimoto, Takumi

    2016-06-01

    The purpose of this study was to clarify the characteristic findings of mesothelioma at the time of diagnosis, and determine precautions and guidelines for diagnosing mesothelioma early in imaging studies. Overall, 327 patients with pleural mesothelioma were selected from 6030 patients who died of mesothelioma between 2003 and 2008 in Japan. Their imaging findings were examined retrospectively. Plaques were found in 35 % of computed tomography (CT) scans. Asbestosis, diffuse pleural thickening, and rounded atelectasis were found in only seven (2 %), five (2 %), and two cases (1 %), respectively. Pleural thickening findings on CT scans were classified into four stages: no irregularity, mild irregularity, high irregularity, and mass formation. Overall, 18 % of cases did not show a clear irregularity. Localized thickening was observed in the mediastinal (77 %) and basal (76 %) pleura and in the interlobar fissure (49 %). Eight percent of cases did not have any thickening in these three areas. Upon examination of the CT scans at diagnosis, 18 % of mesothelioma cases did not show a clear irregularity. When diagnosing pleural effusion of unknown etiology, it is necessary to consider the possibility of mesothelioma even when no plaque and pleural irregularity are observed.

  11. Her2+ and b-HCG Producing Undifferentiated Gastric Adenocarcinoma

    PubMed Central

    Eivaz-Mohammadi, Sahar; Tarar, Omer; Malik, Khurram; Syed, Amer K.

    2014-01-01

    A 25-year-old Hispanic female with a history of anemia, schizoaffective disorder, and psychosis was admitted for anemia associated with fatigue, weakness, shortness of breath, night sweats, weight loss, and abdominal and lower back pain for the past two months. On routine management, she was found to have a positive serum b-HCG of 80.4 (0–5 mIU/mL) but the patient denied any sexual activity in her life. During her admission, U/S of the pelvis was noncontributory. CT angiogram of the chest was significant for prominent mediastinal and hilar lymph nodes, diffusely thickened stomach suggesting gastric malignancy with multiple hypoenhancing lesions in the liver and diffuse lytic lesions in the spine and sacrum suspicious for metastatic disease. The MRI of the abdomen confirmed the CT angiogram findings. After these findings, EGD was performed which showed lesions in the antrum, body of the stomach, fundus, and cardia on the lesser curvature of the stomach body correlating with carcinoma. The biopsy was positive for Her2, b-HCG producing poorly differentiated gastric adenocarcinoma. Patient underwent one successful round of chemotherapy with Taxotene, Cisplatin, and 5-FU for Stage IV gastric adenocarcinoma. PMID:25349615

  12. Child dermoid cyst mimicking a craniopharyngioma: the benefit of MRI T2-weighted diffusion sequence.

    PubMed

    Amelot, Aymeric; Borha, Alin; Calmon, Raphael; Barbet, Patrick; Puget, Stephanie

    2018-02-01

    Brain dermoid cysts are very rare lesions. Although benign, these cysts may be associated with devastating complications due to mass effect or meningitis. The discovery of completely asymptomatic dermoid cysts in the pediatric population is exceedingly rare. Despite the advances in imaging modalities, it sometimes remains difficult to exclude the differential diagnosis of craniopharyngioma. We describe a 12-year-old boy addressed for suspicion of craniopharyngioma diagnosed by decreased visual acuity, bitemporal hemianopia and a CT scan showing a large hypodense suprasellar lesion with intralesional calcifications. Despite the unusual localization and size of this lesion, the absence of dermal sinus commonly found, and before visualizing a hyperintense mass on MRI-diffusion, the diagnosis of craniopharyngioma was ruled out in favor of a dermoid cyst. Radical excision was performed. In the suprasellar area, craniopharyngioma and dermoid cyst may have very similar radiological aspects: low density masses on CT scan and a hyperintense signal on T1-weighted MRI sequences with a variable signal on T2-weighted sequences. Hitherto, only two cases in literature have described suprasellar dermoid cyst. Their initial diagnosis was facilitated by the presence of a dermal sinus.

  13. Kinetics of proton migration in liquid water.

    PubMed

    Chen, Hanning; Voth, Gregory A; Agmon, Noam

    2010-01-14

    We have utilized multistate empirical valence bond (MS-EVB3) simulations of protonated liquid water to calculate the relative mean-square displacement (MSD) and the history-independent time correlation function, c(t), of the hydrated proton center of excess charge (CEC) with respect to the water molecule on which it has initially resided. The MSD is nonlinear for the first 15 ps, suggesting that the relative diffusion coefficient increases from a small value, D(0), at short separations to its larger bulk value, D(infinity), at large separations. With the ensuing distance-dependent diffusion coefficient, D(r), the time dependence of both the MSD and c(t) agrees quantitatively with the solution of a diffusion equation for reversible geminate recombination. This suggests that the relative motion of the CEC is not independent from the nearby water molecules, in agreement with theoretical and experimental observations that large water clusters participate in the mechanism of proton mobility.

  14. Bronchoalveolar carcinoma of lung masquerading as iodine avid metastasis in a patient with minimally invasive follicular carcinoma of thyroid.

    PubMed

    Malhotra, Gaurav; Nair, Narendra; Menon, Hari; Gujral, Sumit; Abhyankar, Amit; Baghel, Nawab S; Awasare, Sushama; Nabar, Swapna J; Abhyankar, Suman; Kand, Purushottam G

    2008-01-01

    A 52-year-old man with follicular thyroid carcinoma was administered 182 mCi of radioiodine (I-131) a month after total thyroidectomy. Post-therapy scan revealed diffuse uptake of radioiodine in the apical left lung. CT-guided biopsy of this mass revealed mucinous bronchoalveolar carcinoma. Immunohistochemistry for thyroglobulin was negative. An FDG PET scan showed avid uptake in the lung mass. Surgery was ruled out, so he was given chemotherapy, without benefit. The lesion continued to show I-131 uptake even while on daily T3 substitution, suggesting that the mass was thyroid stimulating hormone-independent. Because the mass showed I-131 uptake and chemotherapy was not beneficial, it was decided to treat with I-131. He was continued on T3 substitution therapy and was given 209 mCi of I-131. Follow-up CT scan a few weeks later reported a 1-cm all round reduction of the mass. I-131 scan showed avid tracer uptake in the mass. This case suggests the possibility of this therapeutic option in nonthyroidal tumors that may concentrate radioiodine.

  15. Modeling Transport of Cesium in Grimsel Granodiorite With Micrometer Scale Heterogeneities and Dynamic Update of Kd

    NASA Astrophysics Data System (ADS)

    Voutilainen, Mikko; Kekäläinen, Pekka; Siitari-Kauppi, Marja; Sardini, Paul; Muuri, Eveliina; Timonen, Jussi; Martin, Andrew

    2017-11-01

    Transport and retardation of cesium in Grimsel granodiorite taking into account heterogeneity of mineral and pore structure was studied using rock samples overcored from an in situ diffusion test at the Grimsel Test Site. The field test was part of the Long-Term Diffusion (LTD) project designed to characterize retardation properties (diffusion and distribution coefficients) under in situ conditions. Results of the LTD experiment for cesium showed that in-diffusion profiles and spatial concentration distributions were strongly influenced by the heterogeneous pore structure and mineral distribution. In order to study the effect of heterogeneity on the in-diffusion profile and spatial concentration distribution, a Time Domain Random Walk (TDRW) method was applied along with a feature for modeling chemical sorption in geological materials. A heterogeneous mineral structure of Grimsel granodiorite was constructed using X-ray microcomputed tomography (X-μCT) and the map was linked to previous results for mineral specific porosities and distribution coefficients (Kd) that were determined using C-14-PMMA autoradiography and batch sorption experiments, respectively. After this the heterogeneous structure contains information on local porosity and Kd in 3-D. It was found that the heterogeneity of the mineral structure on the micrometer scale affects significantly the diffusion and sorption of cesium in Grimsel granodiorite at the centimeter scale. Furthermore, the modeled in-diffusion profiles and spatial concentration distributions show similar shape and pattern to those from the LTD experiment. It was concluded that the use of detailed structure characterization and quantitative data on heterogeneity can significantly improve the interpretation and evaluation of transport experiments.

  16. 3D GGO candidate extraction in lung CT images using multilevel thresholding on supervoxels

    NASA Astrophysics Data System (ADS)

    Huang, Shan; Liu, Xiabi; Han, Guanghui; Zhao, Xinming; Zhao, Yanfeng; Zhou, Chunwu

    2018-02-01

    The earlier detection of ground glass opacity (GGO) is of great importance since GGOs are more likely to be malignant than solid nodules. However, the detection of GGO is a difficult task in lung cancer screening. This paper proposes a novel GGO candidate extraction method, which performs multilevel thresholding on supervoxels in 3D lung CT images. Firstly, we segment the lung parenchyma based on Otsu algorithm. Secondly, the voxels which are adjacent in 3D discrete space and sharing similar grayscale are clustered into supervoxels. This procedure is used to enhance GGOs and reduce computational complexity. Thirdly, Hessian matrix is used to emphasize focal GGO candidates. Lastly, an improved adaptive multilevel thresholding method is applied on segmented clusters to extract GGO candidates. The proposed method was evaluated on a set of 19 lung CT scans containing 166 GGO lesions from the Lung CT Imaging Signs (LISS) database. The experimental results show that our proposed GGO candidate extraction method is effective, with a sensitivity of 100% and 26.3 of false positives per scan (665 GGO candidates, 499 non-GGO regions and 166 GGO regions). It can handle both focal GGOs and diffuse GGOs.

  17. Diffusion weighted MRI and 18F-FDG PET/CT in non-small cell lung cancer (NSCLC): does the apparent diffusion coefficient (ADC) correlate with tracer uptake (SUV)?

    PubMed

    Regier, M; Derlin, T; Schwarz, D; Laqmani, A; Henes, F O; Groth, M; Buhk, J-H; Kooijman, H; Adam, G

    2012-10-01

    To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). 18F-FDG PET/CT and DWI (TR/TE, 2000/66 ms; b-values, 0 and 500 s/mm(2)) were performed in 41 consecutive patients with histologically verified NSCLC. Analysing the PET-CT data calculation of the mean (SUV(mean)) and maximum (SUV(max)) SUV was performed. By placing a region-of-interest (ROI) encovering the entire tumor mean (ADC(mean)) and minimum ADC (ADC(min)) were determined by two independent radiologists. Results of 18F-FDG PET-CT and DWI were compared on a per-patient basis. For statistical analysis Pearson's correlation coefficient, Bland-Altman and regression analysis were assessed. Data analysis revealed a significant inverse correlation of the ADC(min) and SUV(max) (r=-0.46; p=0.032). Testing the correlation of the ADC(min) and SUV(max) for each histological subtype separately revealed that the inverse correlation was good for both adenocarcinomas (r=-0.47; p=0.03) and squamouscell carcinomas (r=-0.71; p=0.002), respectively. No significant correlation was found for the comparison of ADC(min) and SUV(mean) (r=-0.29; p=0.27), ADC(mean) vs. SUV(mean) (r=-0.28; p=0.31) or ADC(mean) vs. SUV(max) (r=-0.33; p=0.23). The κ-value of 0.88 indicated a good agreement between both observers. This preliminary study is the first to verify the relation between the SUV and the ADC in NSCLC. The significant inverse correlation of these two quantitative imaging approaches points out the association of metabolic activity and tumor cellularity. Therefore, DWI with ADC measurement might represent a new prognostic marker in NSCLC. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  18. The Value of PET/CT in Detecting Bone Marrow Involvement in Patients With Follicular Lymphoma.

    PubMed

    Perry, Chava; Lerman, Hedva; Joffe, Erel; Sarid, Nadav; Amit, Odelia; Avivi, Irit; Kesler, Mikhail; Ben-Ezra, Jonathan; Even-Sapir, Einat; Herishanu, Yair

    2016-03-01

    Follicular lymphoma (FL) is the 2nd most common type of lymphoma diagnosed in the Western World. Bone marrow (BM) involvement is an adverse prognostic factor in FL, routinely assessed by an arbitrary biopsy of the iliac crest. This study was aimed to investigate the role of positron emission tomography/computed tomography (PET/CT) in identifying BM involvement by FL. In this retrospective, single-center study we reviewed the records of consecutive patients with FL at diagnosis or relapse who underwent staging/restaging workup visual assessment of BM uptake was categorized as either normal, diffusely increased, or focally increased. Quantitative BM fluorine-18-fluro-deoxyglucose (FDG) uptake was measured using mean standardized uptake value (BM-SUVmean). The diagnosis of BM involvement was based on either BM histological findings or disappearance of increased uptake at end-treatment PET/CT in patients who responded to treatment. Sixty eight cases with FL were included. Sixteen (23.5%) had BM involvement, 13 (19.1%) had a biopsy proven involvement, and 3 (4.4%) had a negative BM biopsy, but increased medullary uptake that normalized post-treatment. BM FDG uptake in these patients was diffuse in 8 (50%) and focal in 8 (50%). Focal increased uptake was indicative of BM involvement; however, diffuse uptake was associated with 17 false positive cases (32.7%). Overall, visual assessment of BM involvement had a negative predictive value (NPV) of 100% and a positive predictive value (PPV) of 48.5%. On a quantitative assessment, BM-SUVmean was significantly higher in patients with BM involvement (SUVmean of 3.7 [1.7-6] vs 1.4 [0.4-2.65], P < 0.001). On receiver operator curve (ROC) analysis, BM-SUVmean > 2.7 had a PPV of 100% for BM involvement (sensitivity of 68%), while BM-SUVmean < 1.7 had an NPV of 100% (specificity of 73%). Visual assessment of PET/CT is appropriate for ruling out BM involvement by FL. Although focal increased uptake indicates marrow involvement, diffuse uptake is nonspecific. SUV measurement improves PET/CT diagnostic accuracy, identifying additional 19% of patients with BM involvement that would have been otherwise missed.

  19. 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma

    PubMed Central

    Giraudo, Chiara; Raderer, Markus; Karanikas, Georgios; Weber, Michael; Kiesewetter, Barbara; Dolak, Werner; Simonitsch-Klupp, Ingrid; Mayerhoefer, Marius E.

    2016-01-01

    Objectives The aim of this study was to compare 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to 18F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Materials and Methods Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board–approved study. After a single 18F-FDG injection, patients consecutively underwent 18F-FDG PET⁄CT and 18F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on 18F-FDG PET/CT and 18F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Results Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for 18F-FDG PET/CT, 18F-FDG PET/MR, and 18F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. 18F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and 18F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between 18F-FDG PET/MR DWI and 18F-FDG PET/CT, 99.2% (κ, 0.96) between 18F-FDG PET/MR and 18F-FDG PET/CT, and 99.4% (κ, 0.97) between 18F-FDG PET/MR DWI and 18F-FDG PET/MR. There was a strong correlation between 18F-FDG PET/CT and 18F-FDG PET/MR for SUVmax (r = 0.83) and SUVmean (r = 0.81) but no significant correlation between ADCmin and SUVmax (18F-FDG PET/CT: r = 0.46, P = 0.65; 18F-FDG PET/MR: r = 0.64, P = 0.53) or between ADCmean and SUVmean (respectively, r = −0.14, P = 0.17 for the correlation with PET/CT and r = −0.14, P = 0.14 for the correlation with PET/MR). Conclusions 18F-FDG PET/MR and 18F-FDG PET/CT show a similar diagnostic performance in lymphoma patients. However, if DWI is included in the 18F-FDG PET/MR protocol, results surpass those of 18F-FDG PET/CT because of the higher sensitivity of DWI for mucosa-associated lymphoid tissue lymphomas. PMID:26784400

  20. Restrictive allograft syndrome after lung transplantation: new radiological insights.

    PubMed

    Dubbeldam, Adriana; Barthels, Caroline; Coolen, Johan; Verschakelen, Johny A; Verleden, Stijn E; Vos, Robin; Verleden, Geert M; De Wever, Walter

    2017-07-01

    To describe the CT changes in patients with restrictive allograft syndrome (RAS) after lung transplantation, before and after clinical diagnosis. This retrospective study included 22 patients with clinical diagnosis of RAS. Diagnosis was based on a combination of forced expiratory volume (FEV1) decline (≥20 %) and total lung capacity (TLC) decline (≥10 %). All available CT scans after transplantation were analyzed for the appearance and evolution of lung abnormalities. In 14 patients, non-regressing nodules and reticulations predominantly affecting the upper lobes developed an average of 13.9 months prior to the diagnosis of RAS. Median graft survival after onset of non-regressing abnormalities was 33.5 months, with most patients in follow-up (9/14). In eight patients, a sudden appearance of diffuse consolidations mainly affecting both upper and lower lobes was seen an average of 2.8 months prior to the diagnosis of RAS. Median graft survival was 6.4 months after first onset of non-regressing abnormalities, with graft loss in most patients (6/8). RAS has been previously described as a homogenous group. However, our study shows two different groups of RAS-patients: one with slow progression and one with fast progression. The two groups show different onset and progression patterns of CT abnormalities. • RAS is the newest discovered form of chronic lung allograft dysfunction (CLAD). • RAS is not a homogenous group, as survival varies greatly between patients. • In this study, we see two different CT onset and progression patterns. • These two different CT patterns also correlate with a different survival rate.

  1. Pathological and Genetic Characterization of Bilateral Adrenomedullary Hyperplasia in a Patient with Germline MAX Mutation.

    PubMed

    Romanet, Pauline; Guerin, Carole; Pedini, Pascal; Essamet, Wassim; Castinetti, Frédéric; Sebag, Fréderic; Roche, Philippe; Cascon, Alberto; Tischler, Arthur S; Pacak, Karel; Barlier, Anne; Taïeb, David

    2017-12-01

    In recent years, familial pheochromocytoma (PHEO) with germline mutations in the MAX (MYC associated factor X) gene has been reported in a few cases. Here, we investigated a 25-year-old patient with multiple PHEOs associated with a non-sense germline MAX mutation. Preoperative 18 F-FDOPA PET/CT revealed bilateral adrenal involvement with multiple tumors. In addition, both adrenal glands were found to have diffuse or nodular adrenal medullary hyperplasia (AMH), a histopathological feature previously described as a precursor of MEN2- and SDHB-related PHEOs but not MAX. After bilateral adrenalectomy, different paraffin-embedded and frozen samples were analyzed for allelic imbalances of the MAX gene using allelic quantification by pyrosequencing. The expression of the protein MAX was studied by immunohistochemistry. All PHEOs but also nodular AMH exhibited a loss of the normal allele. By contrast, the diffuse AMH did not show loss-of-heterozygosity. Nevertheless, immunohistochemistry demonstrated loss of protein MAX expression in all samples including diffuse hyperplasia, suggesting a causative role of MAX mutation for both PHEOs and AMH. The present case shows that both nodular and diffuse AMH belongs to the spectrum of MAX-related disease. These data support the possible continuum between nodular AMH and PHEO, expanding the qualification of micro-PHEO to nodular AMH.

  2. Comprehensive CT Evaluation in Acute Ischemic Stroke: Impact on Diagnosis and Treatment Decisions

    PubMed Central

    Löve, Askell; Siemund, Roger; Andsberg, Gunnar; Cronqvist, Mats; Holtås, Stig; Björkman-Burtscher, Isabella

    2011-01-01

    Background. With modern CT imaging a comprehensive overview of cerebral macro- and microcirculation can be obtained within minutes in acute ischemic stroke. This opens for patient stratification and individualized treatment. Methods. Four patients with acute ischemic stroke of different aetiologies and/or treatments were chosen for illustration of the comprehensive CT protocol and its value in subsequent treatment decisions. The patients were clinically evaluated according to the NIHSS-scale, examined with the comprehensive CT protocol including both CT angiography and CT perfusion, and followed up by MRI. Results. The comprehensive CT examination protocol increased the examination time but did not delay treatment initiation. In some cases CT angiography revealed the cause of stroke while CT perfusion located and graded the perfusion defect with reasonable accuracy, confirmed by follow-up MR-diffusion. In the presented cases findings of the comprehensive CT examination influenced the treatment strategy. Conclusions. The comprehensive CT examination is a fast and safe method allowing accurate diagnosis and making way for individualized treatment in acute ischemic stroke. PMID:21603175

  3. Lymphoma as a second malignancy in a patient with neuroendocrine tumor: mimicking dedifferentiation on dual-tracer PET/CT with 68Ga-DOTANOC and 18F-FDG.

    PubMed

    Jain, Sachin; Sharma, Punit; Dhull, Varun Singh; Bal, Chandrasekhar; Kumar, Rakesh

    2014-04-01

    Neuroendocrine tumors (NETs) are rare tumors which express somatostatin receptors (SSTRs). We here present a case of a 50-year-old female patient with metastatic bronchial carcinoid. She underwent 68Ga-DOTANOC PET/CT and 18F-FDG PET/CT which suggested a diagnosis of poorly differentiated NET. Biopsy of the lesion, however, revealed a second malignancy in the form of diffuse large B-cell lymphoma. Thus, very rarely, other primary tumors can mimic NETs on dual-tracer PET/CT, and biopsy is advised in doubtful cases.

  4. Minamata disease (organic mercury poisoning): neuroradiologic and electrophysiologic studies.

    PubMed

    Tokuomi, H; Uchino, M; Imamura, S; Yamanaga, H; Nakanishi, R; Ideta, T

    1982-12-01

    We studied 10 patients with Minamata disease (organic mercury poisoning) who have been followed for over 20 years. CT revealed a bilateral, symmetric, low-density area in the visual cortex and diffuse atrophy of the cerebellar hemispheres and vermis, especially the inferior vermis. Computerized quantitative analysis of the tremor of these patients showed a peculiar frequency of 7.075 Hz on postural tremor and 7.501 Hz on action tremor. On studies of short-latency somatosensory evoked potential, all patients showed a lack of the N20 component, the potential of the somatic sensory area.

  5. Computed tomography imaging of a leopard tortoise (Geochelone pardalis pardalis) with confirmed pulmonary fibrosis: a case report

    PubMed Central

    2013-01-01

    An approximately 20-year-old, female Leopard tortoise (Geochelone pardalis pardalis) was presented with dypsnea, wheezing, anorexia and depression. Whole body radiographs revealed generalized diffuse unstructured ‘interstitial lung pattern’ with thickened pulmonary septae while computed tomography (CT) showed emphysematous lung parenchyma and thickened pulmonary septae bordered by irregular ground-glass opacity with smaller areas of ‘honeycombing’. These imaging findings together with histopathologic findings were compatible with chronic, extensive ‘interstitial’ pulmonary fibrosis. PMID:23618386

  6. Mechanisms of azole resistance in a clinical isolate of Candida tropicalis.

    PubMed

    Vandeputte, Patrick; Larcher, Gérald; Bergès, Thierry; Renier, Gilles; Chabasse, Dominique; Bouchara, Jean-Philippe

    2005-11-01

    Azole resistance has been insufficiently investigated in the yeast Candida tropicalis. Here we determined the molecular mechanisms responsible for azole resistance in a clinical isolate of this pathogenic yeast. Antifungal susceptibility testing performed by a disk diffusion method showed resistance or markedly decreased susceptibility to azoles, which was confirmed by determination of MICs. Considering the relationship between azole susceptibility and the respiration reported for other yeast species, the respiratory activity of this isolate was investigated. Flow cytometry using rhodamine 123 and oxygraphy demonstrated an increased respiratory activity, which was not linked to an overexpression or increased number of copies of the mitochondrial genome. Among previously described resistance mechanisms, an increased activity of efflux pumps was investigated by flow cytometry using rhodamine 6G. However, the efflux of rhodamine 6G was lower in the resistant isolate than in susceptible ones. Likewise, real-time reverse transcription-PCR quantification of the expression of C. tropicalis MDR1 (CtMDR1), which encodes an efflux protein belonging to the major facilitator superfamily, did not show overexpression of this gene. In contrast, the resistant isolate overexpressed the CtERG11 gene coding for lanosterol 14alpha-demethylase. This was in agreement with the larger amount of ergosterol found in this isolate. Moreover, sequencing of CtERG11 showed a point mutation leading to a tyrosine substitution in the protein sequence, which might lead to decreased binding affinity for azoles. In conclusion, overexpression of CtERG11 associated with a missense mutation in this gene seemed to be responsible for the acquired azole resistance of this clinical isolate.

  7. Non-invasive detection of infection in acute pancreatic and acute necrotic collections with diffusion-weighted magnetic resonance imaging: preliminary findings.

    PubMed

    Islim, Filiz; Salik, Aysun Erbahceci; Bayramoglu, Sibel; Guven, Koray; Alis, Halil; Turhan, Ahmet Nuray

    2014-06-01

    The purpose of this study was to evaluate the contribution of diffusion-weighted magnetic resonance imaging (DW-MRI) to the detection of infection in acute pancreatitis-related collections. A total of 21 DW-MRI, and computed tomography (CT) were performed on 20 patients diagnosed as acute pancreatitis with acute peri-pancreatic fluid or necrotic collections. Collections were classified as infected or sterile according to the culture and follow-up results. Collections with gas bubbles on CT images were considered to be infected. Collections with peripheral bright signals on DW-MRI images were considered to be positive, whereas those without signals were considered to be negative. Apparent diffusion coefficient (ADC) values of the peripheral and central parts of the collections were measured. Student's t test was used to compare the means of ADC values of independent groups. Apart from one false positive result, the presence of infection was detected by DW-MRI with 95.2% accuracy. The sensitivity and accuracy of DW-MRI were higher than CT for the detection of infection. The ADC values in the central parts of the collections were significantly different between the infected and sterile groups. DW-MRI can be used as a non-invasive technique for the detection of infection in acute pancreatitis-associated collections.

  8. Simultaneous 68Ga-DOTATOC PET/MRI in patients with gastroenteropancreatic neuroendocrine tumors: initial results.

    PubMed

    Beiderwellen, Karsten J; Poeppel, Thorsten D; Hartung-Knemeyer, Verena; Buchbender, Christian; Kuehl, Hilmar; Bockisch, Andreas; Lauenstein, Thomas C

    2013-05-01

    The aim of this pilot study was to demonstrate the potential of simultaneously acquired 68-Gallium-DOTA-D-Phe1-Tyr3-octreotide (68Ga-DOTATOC) positron emission tomography/magnetic resonance imaging (PET/MRI) in comparison with 68Ga-DOTATOC PET/computed tomography (PET/CT) in patients with known gastroenteropancreatic neuroendocrine tumors (NETs). Eight patients (4 women and 4 men; mean [SD] age, 54 [17] years; median, 55 years; range 25-74 years) with histopathologically confirmed NET and scheduled 68Ga-DOTATOC PET/CT were prospectively enrolled for an additional integrated PET/MRI scan. Positron emission tomography/computed tomography was performed using a triple-phase contrast-enhanced full-dose protocol. Positron emission tomography/magnetic resonance imaging encompassed a diagnostic, contrast-enhanced whole-body MRI protocol. Two readers separately analyzed the PET/CT and PET/MRI data sets including their subscans in random order regarding lesion localization, count, and characterization on a 4-point ordinal scale (0, not visible; 1, benign; 2, indeterminate; and 3, malignant). In addition, each lesion was rated in consensus on a binary scale (allowing for benign/malignant only). Clinical imaging, existing prior examinations, and histopathology (if available) served as the standard of reference. In PET-positive lesions, the standardized uptake value (SUV max) was measured in consensus. A descriptive, case-oriented data analysis was performed, including determination of frequencies and percentages in detection of malignant, benign, and indeterminate lesions in connection to their localization. In addition, percentages in detection by a singular modality (such as PET, CT, or MRI) were calculated. Interobserver variability was calculated (Cohen's κ). The SUVs in the lesions in PET/CT and PET/MRI were measured, and the correlation coefficient (Pearson, 2-tailed) was calculated. According to the reference standard, 5 of the 8 patients had malignant NET lesions at the time of the examination. A total of 4 patients were correctly identified by PET/CT, with the PET and CT component correctly identifying 3 patients each. All 5 patients positive for NET disease were correctly identified by PET/MRI, with the MRI subscan identifying all 5 patients and the PET subscan identifying 3 patients. All lesions considered as malignant in PET/CT were equally depicted in and considered using PET/MRI. One liver lesion rated as "indetermined" in PET/CT was identified as metastasis in PET/MRI because of a diffusion restriction in diffusion-weighted imaging. Of the 4 lung lesions characterized in PET/CT, only 1 was depicted in PET/MRI. Of the 3 lymph nodes depicted in PET/CT, only 1 was characterized in PET/MRI. Interobserver reliability was equally very good in PET/CT (κ = 0.916) and PET/MRI (κ = 1.0). The SUV max measured in PET/CT and in PET/MRI showed a strong correlation (Pearson correlation coefficient, 0.996). This pilot study demonstrates the potential of 68Ga-DOTATOC PET/MRI in patients with gastroenteropancreatic NET, with special advantages in the characterization of abdominal lesions yet certain weaknesses inherent to MRI, such as lung metastases and hypersclerotic bone lesions.

  9. Contrast-enhanced CT with a High-Affinity Cationic Contrast Agent for Imaging ex Vivo Bovine, Intact ex Vivo Rabbit, and in Vivo Rabbit Cartilage

    PubMed Central

    Stewart, Rachel C.; Bansal, Prashant N.; Entezari, Vahid; Lusic, Hrvoje; Nazarian, Rosalynn M.; Snyder, Brian D.

    2013-01-01

    Purpose: To quantify the affinity of a cationic computed tomography (CT) contrast agent (CA4+) and that of an anionic contrast agent (ioxaglate) to glycosaminoglycans (GAGs) in ex vivo cartilage tissue explants and to characterize the in vivo diffusion kinetics of CA4+ and ioxaglate in a rabbit model. Materials and Methods: All in vivo procedures were approved by the institutional animal care and use committee. The affinities of ioxaglate and CA4+ to GAGs in cartilage (six bovine osteochondral plugs) were quantified by means of a modified binding assay using micro-CT after plug equilibration in serial dilutions of each agent. The contrast agents were administered intraarticularly to the knee joints of five New Zealand white rabbits to determine the in vivo diffusion kinetics and cartilage tissue imaging capabilities. Kinetics of diffusion into the femoral groove cartilage and relative contrast agent uptake into bovine plugs were characterized by means of nonlinear mixed-effects models. Diffusion time constants (τ) were compared by using a Student t test. Results: The uptake of CA4+ in cartilage was consistently over 100% of the reservoir concentration, whereas it was only 59% for ioxaglate. In vivo, the contrast material–enhanced cartilage reached a steady CT attenuation for both CA4+ and ioxaglate, with τ values of 13.8 and 6.5 minutes, respectively (P = .04). The cartilage was easily distinguishable from the surrounding tissues for CA4+ (12 mg of iodine per milliliter); comparatively, the anionic contrast agent provided less favorable imaging results, even when a higher concentration was used (80 mg of iodine per milliliter). Conclusion: The affinity of the cationic contrast agent CA4+ to GAGs enables high-quality imaging and segmentation of ex vivo bovine and rabbit cartilage, as well as in vivo rabbit cartilage. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12112246/-/DC1 PMID:23192774

  10. Predictors of positive 18F-FDG PET/CT-scan for large vessel vasculitis in patients with persistent polymyalgia rheumatica.

    PubMed

    Prieto-Peña, Diana; Martínez-Rodríguez, Isabel; Loricera, Javier; Banzo, Ignacio; Calderón-Goercke, Mónica; Calvo-Río, Vanesa; González-Vela, Carmen; Corrales, Alfonso; Castañeda, Santos; Blanco, Ricardo; Hernández, José L; González-Gay, Miguel Á

    2018-05-18

    Polymyalgia rheumatica (PMR) is often the presenting manifestation of giant cell arteritis (GCA). Fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) scan often discloses the presence of large vessel vasculitis (LVV) in PMR patients. We aimed to identify predictive factors of a positive PET/CT scan for LVV in patients classified as having isolated PMR according to well-established criteria. A set of consecutive patients with PMR from a single hospital were assessed. All of them underwent PET/CT scan between January 2010 and February 2018 based on clinical considerations. Patients with PMR associated to other diseases, including those with cranial features of GCA, were excluded. The remaining patients were categorized in classic PMR (if fulfilled the 2012 EULAR/ACR classification criteria at disease diagnosis; n = 84) or atypical PMR (who did not fulfill these criteria; n = 16). Only information on patients with classic PMR was assessed. The mean age of the 84 patients (51 women) with classic PMR was 71.4 ± 9.2 years. A PET/CT scan was positive in 51 (60.7%). Persistence of classic PMR symptoms was the most common reason to perform a PET/CT scan. Nevertheless, patients with positive PET/CT scan often had unusual symptoms. The best set of predictors of a positive PET/CT scan were bilateral diffuse lower limb pain (OR = 8.8, 95% CI: 1.7-46.3; p = 0.01), pelvic girdle pain (OR = 4.9, 95% CI: 1.50-16.53; p = 0.01) and inflammatory low back pain (OR = 4.7, 95% CI: 1.03-21.5; p = 0.04). Inflammatory low back pain, pelvic girdle and diffuse lower limb pain are predictors of positive PET/CT scan for LVV in PMR. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Evaluation of computer-based computer tomography stratification against outcome models in connective tissue disease-related interstitial lung disease: a patient outcome study.

    PubMed

    Jacob, Joseph; Bartholmai, Brian J; Rajagopalan, Srinivasan; Brun, Anne Laure; Egashira, Ryoko; Karwoski, Ronald; Kokosi, Maria; Wells, Athol U; Hansell, David M

    2016-11-23

    To evaluate computer-based computer tomography (CT) analysis (CALIPER) against visual CT scoring and pulmonary function tests (PFTs) when predicting mortality in patients with connective tissue disease-related interstitial lung disease (CTD-ILD). To identify outcome differences between distinct CTD-ILD groups derived following automated stratification of CALIPER variables. A total of 203 consecutive patients with assorted CTD-ILDs had CT parenchymal patterns evaluated by CALIPER and visual CT scoring: honeycombing, reticular pattern, ground glass opacities, pulmonary vessel volume, emphysema, and traction bronchiectasis. CT scores were evaluated against pulmonary function tests: forced vital capacity, diffusing capacity for carbon monoxide, carbon monoxide transfer coefficient, and composite physiologic index for mortality analysis. Automated stratification of CALIPER-CT variables was evaluated in place of and alongside forced vital capacity and diffusing capacity for carbon monoxide in the ILD gender, age physiology (ILD-GAP) model using receiver operating characteristic curve analysis. Cox regression analyses identified four independent predictors of mortality: patient age (P < 0.0001), smoking history (P = 0.0003), carbon monoxide transfer coefficient (P = 0.003), and pulmonary vessel volume (P < 0.0001). Automated stratification of CALIPER variables identified three morphologically distinct groups which were stronger predictors of mortality than all CT and functional indices. The Stratified-CT model substituted automated stratified groups for functional indices in the ILD-GAP model and maintained model strength (area under curve (AUC) = 0.74, P < 0.0001), ILD-GAP (AUC = 0.72, P < 0.0001). Combining automated stratified groups with the ILD-GAP model (stratified CT-GAP model) strengthened predictions of 1- and 2-year mortality: ILD-GAP (AUC = 0.87 and 0.86, respectively); stratified CT-GAP (AUC = 0.89 and 0.88, respectively). CALIPER-derived pulmonary vessel volume is an independent predictor of mortality across all CTD-ILD patients. Furthermore, automated stratification of CALIPER CT variables represents a novel method of prognostication at least as robust as PFTs in CTD-ILD patients.

  12. Distinguishing Betwen Effects of Local Inputs (Contaminated Sediments, Point Sources) and Upstream Diffuse Nonpoint Source Input: Refinement of a Watershed Development Index for New England

    EPA Science Inventory

    Assessment tools are being developed to predict diffuse NPS effects from watershed development and distinguish these from local impacts (point sources, contaminated sediments). Using EMAP data from the New England Wadeable Stream Survey and two state datasets (CT, ME), we are de...

  13. Acute fibrinous and organising pneumonia.

    PubMed

    Guimarães, Catarina; Sanches, Inês; Ferreira, Catarina

    2012-03-20

    Acute fibrinous and organising pneumonia (AFOP) was recently described as an unusual pattern of diffuse lung disease. Particular characteristics make the differential diagnosis with the well recognised clinical patterns of diffuse alveolar damage, cryptogenic organising pneumonia or eosinophilic pneumonia. The lack of hyaline membranes, the presence of intra-alveolar fibrin, absence of noticeable eosinophils and patchy distribution suggests that AFOP define a distinct histological pattern. The authors describe the case of a woman diagnosed with AFOP after surgical lung biopsy, in association with primary biliary cirrhosis. The patient presented dyspnoea, fatigue, dry cough and thoracic pain. The CT scan showed bilateral patchy infiltrates predominantly in the lower lobes. Flexible bronchoscopy and subsidiary techniques were inconclusive and biopsy through video-assisted thoracoscopic surgery led to anatomopathological diagnosis of AFOP. The patient is having a good clinical response to prednisone.

  14. Pleural irregularities and mediastinal pleural involvement in early stages of malignant pleural mesothelioma and benign asbestos pleural effusion.

    PubMed

    Kato, Katsuya; Gemba, Kenichi; Fujimoto, Nobukazu; Aoe, Keisuke; Takeshima, Yukio; Inai, Kouki; Kishimoto, Takumi

    2016-09-01

    To elucidate differences in the level and localization of pleural irregularities in early malignant pleural mesothelioma (eMPM) and benign asbestos pleural effusion (BAPE) using CT. Retrospective assessment of CT findings of consecutive patients with BAPE at a single centre and patients with eMPM reported in Japanese vital statistics. Thirty-six patients with confirmed diagnoses of BAPE and sixty-six patients with confirmed diagnoses of eMPM (mesothelioma stages T1 or T2) were included. Informed consent, CT scans, and clinical and pathologic details were obtained for all patients and were reviewed by one radiologist, two pathologists, and two pulmonologists. Asbestosis, pleural plaque, rounded atelectasis, and diffuse pleural thickening were assessed in all patients. Prevalence of asbestosis, pleural plaque, rounded atelectasis, and diffuse pleural thickening was significantly higher in the BAPE group. Low-level irregularity was more common in the BAPE group (p<0.001), whereas high-level irregularity, mediastinal localization, and interlobar fissure were more prevalent in the eMPM group (p<0.001). Interlobar pleural irregularity was not observed in any patients in the BAPE group, although 55% of patients in the eMPM group showed interlobar pleural irregularity. Mediastinal pleural involvement was observed in 74% of patients in the eMPM group and had a positive predictive value of 89%. This study demonstrates that the level and localization of plural irregularities significantly differed between patients with BAPE and eMPM. Large-scale prospective studies are needed to fully establish the diagnostic utility of such differences. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishnan, Kalpagam; Liu, Jeff; Kohli, Kirpal

    Purpose: Fusion of electrical impedance tomography (EIT) with computed tomography (CT) can be useful as a clinical tool for providing additional physiological information about tissues, but requires suitable fusion algorithms and validation procedures. This work explores the feasibility of fusing EIT and CT images using an algorithm for coregistration. The imaging performance is validated through feature space assessment on phantom contrast targets. Methods: EIT data were acquired by scanning a phantom using a circuit, configured for injecting current through 16 electrodes, placed around the phantom. A conductivity image of the phantom was obtained from the data using electrical impedance andmore » diffuse optical tomography reconstruction software (EIDORS). A CT image of the phantom was also acquired. The EIT and CT images were fused using a region of interest (ROI) coregistration fusion algorithm. Phantom imaging experiments were carried out on objects of different contrasts, sizes, and positions. The conductive medium of the phantoms was made of a tissue-mimicking bolus material that is routinely used in clinical radiation therapy settings. To validate the imaging performance in detecting different contrasts, the ROI of the phantom was filled with distilled water and normal saline. Spatially separated cylindrical objects of different sizes were used for validating the imaging performance in multiple target detection. Analyses of the CT, EIT and the EIT/CT phantom images were carried out based on the variations of contrast, correlation, energy, and homogeneity, using a gray level co-occurrence matrix (GLCM). A reference image of the phantom was simulated using EIDORS, and the performances of the CT and EIT imaging systems were evaluated and compared against the performance of the EIT/CT system using various feature metrics, detectability, and structural similarity index measures. Results: In detecting distilled and normal saline water in bolus medium, EIT as a stand-alone imaging system showed contrast discrimination of 47%, while the CT imaging system showed a discrimination of only 1.5%. The structural similarity index measure showed a drop of 24% with EIT imaging compared to CT imaging. The average detectability measure for CT imaging was found to be 2.375 ± 0.19 before fusion. After complementing with EIT information, the detectability measure increased to 11.06 ± 2.04. Based on the feature metrics, the functional imaging quality of CT and EIT were found to be 2.29% and 86%, respectively, before fusion. Structural imaging quality was found to be 66% for CT and 16% for EIT. After fusion, functional imaging quality improved in CT imaging from 2.29% to 42% and the structural imaging quality of EIT imaging changed from 16% to 66%. The improvement in image quality was also observed in detecting objects of different sizes. Conclusions: The authors found a significant improvement in the contrast detectability performance of CT imaging when complemented with functional imaging information from EIT. Along with the feature assessment metrics, the concept of complementing CT with EIT imaging can lead to an EIT/CT imaging modality which might fully utilize the functional imaging abilities of EIT imaging, thereby enhancing the quality of care in the areas of cancer diagnosis and radiotherapy treatment planning.« less

  16. Three-dimensional dosimetry of small megavoltage radiation fields using radiochromic gels and optical CT scanning

    NASA Astrophysics Data System (ADS)

    Babic, Steven; McNiven, Andrea; Battista, Jerry; Jordan, Kevin

    2009-04-01

    The dosimetry of small fields as used in stereotactic radiotherapy, radiosurgery and intensity-modulated radiation therapy can be challenging and inaccurate due to partial volume averaging effects and possible disruption of charged particle equilibrium. Consequently, there exists a need for an integrating, tissue equivalent dosimeter with high spatial resolution to avoid perturbing the radiation beam and artificially broadening the measured beam penumbra. In this work, radiochromic ferrous xylenol-orange (FX) and leuco crystal violet (LCV) micelle gels were used to measure relative dose factors (RDFs), percent depth dose profiles and relative lateral beam profiles of 6 MV x-ray pencil beams of diameter 28.1, 9.8 and 4.9 mm. The pencil beams were produced via stereotactic collimators mounted on a Varian 2100 EX linear accelerator. The gels were read using optical computed tomography (CT). Data sets were compared quantitatively with dosimetric measurements made with radiographic (Kodak EDR2) and radiochromic (GAFChromic® EBT) film, respectively. Using a fast cone-beam optical CT scanner (Vista™), corrections for diffusion in the FX gel data yielded RDFs that were comparable to those obtained by minimally diffusing LCV gels. Considering EBT film-measured RDF data as reference, cone-beam CT-scanned LCV gel data, corrected for scattered stray light, were found to be in agreement within 0.5% and -0.6% for the 9.8 and 4.9 mm diameter fields, respectively. The validity of the scattered stray light correction was confirmed by general agreement with RDF data obtained from the same LCV gel read out with a laser CT scanner that is less prone to the acceptance of scattered stray light. Percent depth dose profiles and lateral beam profiles were found to agree within experimental error for the FX gel (corrected for diffusion), LCV gel (corrected for scattered stray light), and EBT and EDR2 films. The results from this study reveal that a three-dimensional dosimetry method utilizing optical CT-scanned radiochromic gels allows for the acquisition of a self-consistent volumetric data set in a single exposure, with sufficient spatial resolution to accurately characterize small fields.

  17. Diffuse consolidation form of bronchoalveolar carcinoma.

    PubMed

    Khalil, Kanwal Fatima; Saeed, Waseem; Zill-e-Hamayun

    2010-03-01

    This case report describes a patient with diffuse consolidation form of bronchoalveolar carcinoma (BAC) which is a rare type of adenocarcinoma of lung. He was diagnosed on the basis of findings on X-ray and high resolution CT(HRCT) chest later confirmed by open lung biopsy and immuno-histochemical staining. Only supportive treatment could be provided and the patient expired during the subsequent month of follow-up. Traditionally, diffuse consolidation is the radiological presentation in only 20% of patients with bronchoalveolar carcinoma.

  18. Diffuse large B-cell lymphoma presenting as a unilateral solitary round pulmonary hilar node infarction.

    PubMed

    Yonemori, Kan; Kusumoto, Masahiko; Matsuno, Yoshihiro; Tateishi, Ukihide; Watanabe, Shun-Ichi; Watanabe, Takashi; Moriyama, Noriyuki

    2006-03-01

    Unilateral solitary pulmonary hilar node adenopathy is a rare presentation of diffuse large B-cell lymphoma. In this report, the authors present a case with a solitary pulmonary hilar lymph node infarction caused by diffuse large B-cell lymphoma. Enhanced CT examinations revealed a well-defined round mass with homogenous low attenuation in the left pulmonary hilum. Both radiological imaging and pathological examination can provide useful information for the interpretation of abnormalities and may enable the diagnosis of rare aetiologies.

  19. Proton tracking in a high-granularity Digital Tracking Calorimeter for proton CT purposes

    NASA Astrophysics Data System (ADS)

    Pettersen, H. E. S.; Alme, J.; Biegun, A.; van den Brink, A.; Chaar, M.; Fehlker, D.; Meric, I.; Odland, O. H.; Peitzmann, T.; Rocco, E.; Ullaland, K.; Wang, H.; Yang, S.; Zhang, C.; Röhrich, D.

    2017-07-01

    Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the target volume in a patient. Imaging methods and modalities, such as Dual Energy CT and proton CT, have come into consideration in the pursuit of obtaining an as good as possible estimate of the proton stopping power. In this study, a Digital Tracking Calorimeter is benchmarked for proof-of-concept for proton CT purposes. The Digital Tracking Calorimeter was originally designed for the reconstruction of high-energy electromagnetic showers for the ALICE-FoCal project. The presented prototype forms the basis for a proton CT system using a single technology for tracking and calorimetry. This advantage simplifies the setup and reduces the cost of a proton CT system assembly, and it is a unique feature of the Digital Tracking Calorimeter concept. Data from the AGORFIRM beamline at KVI-CART in Groningen in the Netherlands and Monte Carlo simulation results are used to in order to develop a tracking algorithm for the estimation of the residual ranges of a high number of concurrent proton tracks. High energy protons traversing the detector leave a track through the sensor layers. These tracks are spread out through charge diffusion processes. A charge diffusion model is applied for acquisition of estimates of the deposited energy of the protons in each sensor layer by using the size of the charge diffused area. A model fit of the Bragg Curve is applied to each reconstructed track and through this, estimating the residual range of each proton. The range of the individual protons can at present be estimated with a resolution of 4%. The readout system for this prototype is able to handle an effective proton frequency of 1 MHz by using 500 concurrent proton tracks in each readout frame, which is at the high end range of present similar prototypes. A future further optimized prototype will enable a high-speed and more accurate determination of the ranges of individual protons in a therapeutic beam.

  20. [Usefulness of Edoxaban for Deep Cerebral Venous Sinus Thrombosis with Hemorrhagic Infarction:A Case Report].

    PubMed

    Amemiya, Takeo; Uesaka, Toshio; Kameda, Katsuharu; Uno, Junji; Nagaoka, Shintaro; Ikai, Yoshiaki; Gi, Hidefuku

    2017-07-01

    We describe a case of deep cerebral venous sinus thrombosis(DCVST)that was successfully treated by oral administration of the Xa inhibitor edoxaban. A 53-year-old man was admitted to our hospital because of a headache and undifferentiated dizziness. Computed tomography(CT)demonstrated a low-density area in the bilateral thalamus and high-density lesions in the internal cerebral veins(ICVs)and vein of Galen. Magnetic resonance imaging with diffusion-weighted images detected areas of hyperintensity in the bilateral thalamus. Additionally, the inferior sagittal sinus, ICV, and vein of Galen were not detected by CT venography or cerebral angiography. We therefore diagnosed DCVST and started anticoagulation therapy with heparin(IV)and warfarin. A week after admission, lesions that showed hypointensity on T2* images and high density on CT scans were detected in the bilateral thalamus. We thought that hemorrhagic infarction had occurred in association with DCVST, and changed the anticoagulation therapy to oral administration of edoxaban on day 9. The patient's symptoms gradually diminished, and CT venography indicated partial recanalization of the DCV from the ICV to the vein of Galen on day 72. We report our experience, and discuss the safety and usefulness of the Xa inhibitor for treating DCVST with hemorrhagic infarction.

  1. [A case of myasthenia gravis with invasive thymoma associated with diffuse panbronchiolitis, alopecia, dysgeusia, cholangitis and myositis].

    PubMed

    Maekawa, Risa; Shibuya, Hideki; Hideyama, Takuto; Shiio, Yasushi

    2014-01-01

    A 43-year-old man was admitted to our hospital because of diplopia, ptosis, and dysphagia that had begun three years previously. He was diagnosed with myasthenia gravis (MG) and invasive thymoma and treated with corticosteroid, thymectomy, and radiation therapy. Ten years after the thymectomy, computed tomography (CT) showed metastasis of the thymoma in the left lower lobe of the lung. Two years after this recurrence, when the patient was 55, respiratory symptoms such as wheezing, persistent cough, and dyspnea appeared. Chronic sinusitis, diffuse centrilobular opacities on CT, and positivity for HLA-B54 led to a diagnosis of diffuse panbronchiolitis (DPB). Despite treatment with clarithromycin, the respiratory symptoms worsened. The patient developed alopecia and body hair loss at the age of 56 followed by dysgeusia, cholangitis, and myositis with positivity for anti-Kv1.4 antibodies. Although treatment with an increased dose of corticosteroid improved hair loss, dysgeusia, cholangitis, and myositis, he died of progression of DPB and serious respiratory infection at the age of 58. In this case, various autoimmune disorders occurred together with MG as complications of thymoma. Although alopecia, dysgeusia, and myositis are already known as complications of MG associated with thymoma, cholangitis is not well-recognized since there have been few reports suggesting a causal relationship between cholangitis and thymoma. Furthermore, DPB caused by immunodeficiency and respiratory tract hypersensitivity associated with thymoma and HLA-B54, respectively, is the distinctive feature of our case. Neurologists should be aware that various organs can be damaged directly and indirectly by abnormal T cells from thymoma in patients with MG.

  2. Transformation of Follicular Lymphoma to a High-Grade B-Cell Lymphoma With MYC and BCL2 Translocations and Overlapping Features of Burkitt Lymphoma and Acute Lymphoblastic Leukemia: A Case Report and Literature Review.

    PubMed

    Bischin, Alina M; Dorer, Russell; Aboulafia, David M

    2017-01-01

    Most commonly, histologic transformation (HT) from follicular lymphoma (FL) manifests as a diffuse large B-cell lymphoma, not otherwise specified (DLBCL, NOS). Less frequently, HT may result in a high-grade B-cell lymphoma (HGBL) with MYC and B-cell lymphoma protein 2 (BCL2) and/or BCL6 gene rearrangements, also known as "double-hit" or "triple-hit" lymphomas. In the 2016 revision of the World Health Organization (WHO) classification of lymphoid neoplasms, the category B-cell lymphoma, unclassifiable was eliminated due to its vague criteria and limiting diagnostic benefit. Instead, the WHO introduced the HGBL category, characterized by MYC and BCL2 and/or BCL6 rearrangements. Cases that present as an intermediate phenotype of DLBCL and Burkitt lymphoma (BL) will fall within this HGBL category. Very rarely, HT results in both the intermediate DLBCL and BL phenotypes and exhibits lymphoblastic features, in which case the WHO recommends that this morphologic appearance should be noted. In comparison with de novo patients with DLBCL, NOS, those with MYC and BCL2 and/or BCL6 gene rearrangements have a worse prognosis. A 63-year-old woman presented with left neck adenopathy. Laboratory assessments, including complete blood count, complete metabolic panel, serum lactate dehydrogenase, and β 2 -microglobulin, were all normal. A whole-body computerized tomographic (CT) scan revealed diffuse adenopathy above and below the diaphragm. An excisional node biopsy showed grade 3A nodular FL. The Ki67 labeling index was 40% to 50%. A bone marrow biopsy showed a small focus of paratrabecular CD20+ lymphoid aggregates. She received 6 cycles of bendamustine (90 mg/m2 on days +1 and +2) and rituximab (375 mg/m2 on day +2), with each cycle delivered every 4 weeks. A follow-up CT scan at completion of therapy showed a partial response with resolution of axillary adenopathy and a dramatic shrinkage of the large retroperitoneal nodes. After 18 months, she had crampy abdominal pain in the absence of B symptoms. Positron emission tomography with 2-deoxy-2-[fluorine-18] fluoro-d-glucose integrated with CT (18F-FDG PET/CT) scan showed widespread adenopathy, diffuse splenic involvement, and substantial marrow involvement. Biopsy of a 2.4-cm right axillary node (SUVmax of 16.1) showed involvement by grade 3A FL with a predominant nodular pattern of growth. A bone marrow biopsy once again showed only a small focus of FL. She received idelalisib (150 mg twice daily) and rituximab (375 mg/m2, monthly) beginning May 2015. After 4 cycles, a repeat CT scan showed a complete radiographic response. Idelalisib was subsequently held while she received corticosteroids for immune-mediated colitis. A month later, she restarted idelalisib with a 50% dose reduction. After 2 weeks, she returned to clinic complaining of bilateral hip and low lumbar discomfort but no B symptoms. A restaging 18F-FDG PET/CT in January 2016 showed dramatic marrow uptake. A bone marrow aspirate showed sheets of tumor cells representing a spectrum from intermediate-sized cells with lymphoblastic features to very large atypical cells with multiple nucleoli. Two distinct histologies were present; one remained consistent with the patient's known FL with a predominant nodular pattern and the other consistent with HT (the large atypical cells expressed PAX5, CD10, BCL2, and c-MYC and were negative for CD20, MPO, CD34, CD30, and BCL6). Focal areas showed faint, heterogeneous expression of terminal deoxynucleotidyl transferase best seen on the clot section. Ki67 proliferation index was high (4+/4). Fluorescence in situ hybridization analysis showed 2 populations with MYC amplification and/or rearrangement and no evidence of BCL6 rearrangement; a karyotype analysis showed a complex abnormal female karyotype with t(14;18) and multiple structural and numerical abnormalities. She started dose-adjusted rituximab, etoposide, prednisone, vincristine, cyclophosphamide, and doxorubicin with concomitant prophylactic intrathecal methotrexate and cytarabine. She had but a short-lived response before dying in hospice from progressive lymphoma. Whether idelalisib could provide a microenvironment for selection of more aggressive clones needs to be addressed. Our patient's clinical course is confounded by the incorporation of idelalisib while being further complicated by the complexity of HT and the mechanisms in which first-line chemotherapy regimens affect double-hit lymphoma.

  3. FINAL REPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PETER, GARY F.

    2014-07-16

    Excellent progress was made in standardizing three complementary methods: Magnetic resonance imaging, x-ray micro CT, and MALDI imaging linear ion trap mass spectroscopy to image biomass and chemical, anatomical and functional changes that occur during pretreatment and hydrolysis. Magnetic resonance microscopy provides excellent images with as low as 5 uM resolution with hydrated biomass samples. We visualized dramatic changes in signal associated with the hydrolysis of the carbohydrates by strong acids. Quantitative diffusion approaches were used to probe more subtle structural changes in biomass. Diffusion tensor calculations reflect diffusion anisotropy and fractional anisotropy maps clearly show the longer range diffusionmore » within the vessels compared to within the fiber cells. The diffusion is increased along the cell walls of the vessels. Suggesting that further research with NMR imaging should be pursued. X-ray CT provides excellent images at as low as 3.5 uM resolution from dried biomass. Small increases in surface area, and decreases in local density have been quantified in with wood after mild pretreatments; these changes are expected to be underestimates of the hydrated wood, due to the ~12% shrinkage that occurs upon drying untreated wood. MALDI-MS spectra show high ion intensities at most mass to charge ratios in untreated and pretreated woody material. MALDI-MSn is required to improve specificity and reduce background for imaging. MALDI-TOF is not specific enough for carbohydrate identification. Using MALDI-LIT/MSn we can readily identify oligomeric glucans and xylans and their fragmentation patterns as well as those of the glucuronic acid side chains of birch 4-O-methyl glucuronxylan. Imaging of glucan and xylan oligomers show that many contain isobaric ions with different distributions, indicating again that MSn is needed for accurate imaging of lignocellulosic materials. We are now starting to integrate the three imaging methods by using the same set of biomass samples imaged with all three methods, and using common analytical software to quantify parameters from the three dimensional images. In addition to the proposed experiments, we conducted imaging studies with a novel TOF-SIMS instrument available through collaborations with the AMOLF goup led by Ron Heeren at the FOM Institute in Amersterdam, Netherlands. ToF-SIMS was used to image intact cross sections of Populus stems with high spatial resolution, chemically selectivity. ToF-SIMS images were correlated with fluorescence microscopy which allowed for more positive ion identification.« less

  4. Impact of functional focal versus diffuse coronary artery disease on bypass graft patency.

    PubMed

    Shiono, Yasutsugu; Kubo, Takashi; Honda, Kentaro; Katayama, Yosuke; Aoki, Hiroshi; Satogami, Keisuke; Kashiyama, Kuninobu; Taruya, Akira; Nishiguchi, Tsuyoshi; Kuroi, Akio; Orii, Makoto; Kameyama, Takeyoshi; Yamano, Takashi; Yamaguchi, Tomoyuki; Matsuo, Yoshiki; Ino, Yasushi; Tanaka, Atsushi; Hozumi, Takeshi; Nishimura, Yoshiharu; Okamura, Yoshitaka; Akasaka, Takashi

    2016-11-01

    Pressure guidewire pullback recording can differentiate between functional focal and diffuse disease types in coronary artery disease. The aim of this study was to compare the outcome of coronary artery bypass graft (CABG) patency between patients with functional focal versus diffuse disease types in recipient coronary arteries. We investigated 89 patients who underwent pressure guidewire pullback in the left anterior descending (LAD) artery before CABG using internal mammary artery (IMA). Based on the pressure guidewire pullback data, the LAD lesions were classified into functional focal disease (abrupt pressure step-up; n=58) or functional diffuse disease (gradual pressure increase; n=31). Follow-up computed tomography (CT) angiography was conducted within 1year after CABG to assess the bypass graft patency. Pre CABG, LAD angiographic percent diameter stenosis (57±10% vs. 54±12%, p=0.228) and fractional flow reserve (FFR) (0.68±0.07 vs. 0.69±0.07, p=0.244) were not different between the functional focal and diffuse disease groups. The CABG procedure characteristics were similarly comparable between the two groups. In the follow-up CT angiography after CABG, occlusion or string sign of the IMA graft to LAD was more frequently observed in the functional diffuse disease group than in the functional focal disease group (26% vs. 7%, p=0.021). In CABG, functional diffuse disease in the recipient coronary artery was associated with an increased risk of the graft failure in comparison with functional focal disease. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Diffuse FDG uptake due to fat necrosis following transverse rectus abdominus myocutaneous (TRAM) flap reconstruction.

    PubMed

    Dobbs, Nathan B; Latifi, Hamid R

    2013-08-01

    We report a case of a 57-year-old female patient with right breast invasive ductal carcinoma. Bilateral mastectomy and TRAM flap reconstructions were performed. Postoperatively, a palpable focus was identified within the left breast. PET/CT showed hypermetabolism throughout the reconstructed left breast, correlating with mixed fat attenuation and inflammatory soft tissue. MRI showed extensive fat necrosis/oil cyst formation in the left breast. As a TRAM flap reconstruction with fat-rich tissue can be damaged intraoperatively due to surgical manipulation, abnormal FDG uptake in this setting is more likely related to fat necrosis than recurrent tumor.

  6. Disease quantification on PET/CT images without object delineation

    NASA Astrophysics Data System (ADS)

    Tong, Yubing; Udupa, Jayaram K.; Odhner, Dewey; Wu, Caiyun; Fitzpatrick, Danielle; Winchell, Nicole; Schuster, Stephen J.; Torigian, Drew A.

    2017-03-01

    The derivation of quantitative information from images to make quantitative radiology (QR) clinically practical continues to face a major image analysis hurdle because of image segmentation challenges. This paper presents a novel approach to disease quantification (DQ) via positron emission tomography/computed tomography (PET/CT) images that explores how to decouple DQ methods from explicit dependence on object segmentation through the use of only object recognition results to quantify disease burden. The concept of an object-dependent disease map is introduced to express disease severity without performing explicit delineation and partial volume correction of either objects or lesions. The parameters of the disease map are estimated from a set of training image data sets. The idea is illustrated on 20 lung lesions and 20 liver lesions derived from 18F-2-fluoro-2-deoxy-D-glucose (FDG)-PET/CT scans of patients with various types of cancers and also on 20 NEMA PET/CT phantom data sets. Our preliminary results show that, on phantom data sets, "disease burden" can be estimated to within 2% of known absolute true activity. Notwithstanding the difficulty in establishing true quantification on patient PET images, our results achieve 8% deviation from "true" estimates, with slightly larger deviations for small and diffuse lesions where establishing ground truth becomes really questionable, and smaller deviations for larger lesions where ground truth set up becomes more reliable. We are currently exploring extensions of the approach to include fully automated body-wide DQ, extensions to just CT or magnetic resonance imaging (MRI) alone, to PET/CT performed with radiotracers other than FDG, and other functional forms of disease maps.

  7. The Rate and Clinical Significance of Incidental Thyroid Uptake as Detected by Gallium-68 DOTATATE Positron Emission Tomography/Computed Tomography

    PubMed Central

    Nockel, Pavel; Millo, Corina; Keutgen, Xavier; Klubo-Gwiezdzinska, Joanna; Shell, Jasmine; Patel, Dhaval; Nilubol, Naris; Herscovitch, Peter; Sadowski, Samira M.

    2016-01-01

    Background: Gallium-68 (Ga-68) DOTATATE is a radiolabeled peptide–imaging modality that targets the somatostatin receptor (SSTR), especially subtype 2 (SSTR2). Benign and malignant thyroid tumors have been observed to express SSTR. The aim of this study was to evaluate the frequency and clinical significance of incidental atypical thyroid uptake as detected by Ga-68 DOTATATE positron emission tomography/computed tomography (PET/CT). Methods: A retrospective analysis was conducted of a prospective study in which 237 patients underwent Ga-68 DOTATATE PET/CT as part of a work-up for metastatic and unknown primary neuroendocrine tumors. The types of uptake in the thyroid gland (focal/diffuse) and maximum standardized uptake value (SUVmax) levels were evaluated and compared with the background uptake in the liver and salivary glands. Results: Of 237 patients, 26 (11%) had atypical thyroid uptake as detected by Ga-68 DOTATATE PET/CT. There were no significant clinical or biochemical variables associated with atypical thyroid uptake. Fourteen (54%) patients had positive focal uptake, and 12 (46%) patients had diffuse uptake. Of the 14 patients with atypical focal uptake, 10 (71%) had thyroid nodules on the corresponding side, as detected by anatomic imaging. Three of 10 patients (21%) were found to have papillary thyroid cancer, and seven (70%) had adenomatoid nodules. Of the 12 patients with diffuse increased uptake, six (50%) had a history of hypothyroidism, five (42%) had chronic lymphocytic thyroiditis, and one (8%) had nontoxic multinodular goiter. Conclusions: Patients with an incidental focal abnormal thyroid uptake on Ga-68 DOTATATE PET/CT scan should have further clinical evaluation to exclude a diagnosis of thyroid cancer. PMID:27094616

  8. Diffusion-weighted-preparation (D-prep) MRI as a future extension of SPECT/CT based surgical planning for sentinel node procedures in the head and neck area?

    PubMed

    Buckle, Tessa; KleinJan, Gijs H; Engelen, Thijs; van den Berg, Nynke S; DeRuiter, Marco C; van der Heide, Uulke; Valdes Olmos, Renato A; Webb, Andrew; van Buchem, Mark A; Balm, Alfons J; van Leeuwen, Fijs W B

    2016-09-01

    Even when guided by SPECT/CT planning of nodal resection in the head-and-neck area is challenging due to the many critical anatomical structures present within the surgical field. In this study the potential of a (SPECT/)MRI-based surgical planning method was explored. Hereby MRI increases the identification of SNs within clustered lymph nodes (LNs) and vital structures located adjacent to the SN (such as cranial nerve branches). SPECT/CT and pathology reports from 100 head-and-neck melanoma and 40 oral cavity cancer patients were retrospectively assessed for SN locations in levels I-V and degree of nodal clustering. A diffusion-weighted-preparation magnetic resonance neurography (MRN) sequence was used in eight healthy volunteers to detect LNs and peripheral nerves. In 15% of patients clustered nodes were retrospectively shown to be present at the location where the SN was identified on SPECT/CT (level IIA: 37.2%, level IIB: 21.6% and level III: 15.5%). With MRN, improved LN delineation enabled discrimination of individual LNs within a cluster. Uniquely, this MRI technology also provided insight in LN distribution (23.2±4 LNs per subject) and size (range 21-372mm(3)), and enabled non-invasive assessment of anatomical variances in the location of the LNs and facial nerves. Diffusion-weighted-preparation MRN enabled improved delineation of LNs and their surrounding delicate anatomical structures in the areas that most often harbor SNs in the head-and-neck. Based on our findings a combined SPECT/MRI approach is envisioned for future surgical planning of complex SN resections in this region. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Magnetic Resonance Imaging of Liver Metastasis.

    PubMed

    Karaosmanoglu, Ali Devrim; Onur, Mehmet Ruhi; Ozmen, Mustafa Nasuh; Akata, Deniz; Karcaaltincaba, Musturay

    2016-12-01

    Liver magnetic resonance imaging (MRI) is becoming the gold standard in liver metastasis detection and treatment response assessment. The most sensitive magnetic resonance sequences are diffusion-weighted images and hepatobiliary phase images after Gd-EOB-DTPA. Peripheral ring enhancement, diffusion restriction, and hypointensity on hepatobiliary phase images are hallmarks of liver metastases. In patients with normal ultrasonography, computed tomography (CT), and positron emission tomography (PET)-CT findings and high clinical suspicion of metastasis, MRI should be performed for diagnosis of unseen metastasis. In melanoma, colon cancer, and neuroendocrine tumor metastases, MRI allows confident diagnosis of treatment-related changes in liver and enables differential diagnosis from primary liver tumors. Focal nodular hyperplasia-like nodules in patients who received platinum-based chemotherapy, hypersteatosis, and focal fat can mimic metastasis. In cancer patients with fatty liver, MRI should be preferred to CT. Although the first-line imaging for metastases is CT, MRI can be used as a problem-solving method. MRI may be used as the first-line method in patients who would undergo curative surgery or metastatectomy. Current limitation of MRI is low sensitivity for metastasis smaller than 3mm. MRI fingerprinting, glucoCEST MRI, and PET-MRI may allow simpler and more sensitive diagnosis of liver metastasis. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Diffuse optical tomography for breast cancer imaging guided by computed tomography: A feasibility study.

    PubMed

    Baikejiang, Reheman; Zhang, Wei; Li, Changqing

    2017-01-01

    Diffuse optical tomography (DOT) has attracted attentions in the last two decades due to its intrinsic sensitivity in imaging chromophores of tissues such as hemoglobin, water, and lipid. However, DOT has not been clinically accepted yet due to its low spatial resolution caused by strong optical scattering in tissues. Structural guidance provided by an anatomical imaging modality enhances the DOT imaging substantially. Here, we propose a computed tomography (CT) guided multispectral DOT imaging system for breast cancer imaging. To validate its feasibility, we have built a prototype DOT imaging system which consists of a laser at the wavelength of 650 nm and an electron multiplying charge coupled device (EMCCD) camera. We have validated the CT guided DOT reconstruction algorithms with numerical simulations and phantom experiments, in which different imaging setup parameters, such as projection number of measurements and width of measurement patch, have been investigated. Our results indicate that an air-cooling EMCCD camera is good enough for the transmission mode DOT imaging. We have also found that measurements at six angular projections are sufficient for DOT to reconstruct the optical targets with 2 and 4 times absorption contrast when the CT guidance is applied. Finally, we have described our future research plan on integration of a multispectral DOT imaging system into a breast CT scanner.

  11. Comparison Study of Regularizations in Spectral Computed Tomography Reconstruction

    NASA Astrophysics Data System (ADS)

    Salehjahromi, Morteza; Zhang, Yanbo; Yu, Hengyong

    2018-12-01

    The energy-resolving photon-counting detectors in spectral computed tomography (CT) can acquire projections of an object in different energy channels. In other words, they are able to reliably distinguish the received photon energies. These detectors lead to the emerging spectral CT, which is also called multi-energy CT, energy-selective CT, color CT, etc. Spectral CT can provide additional information in comparison with the conventional CT in which energy integrating detectors are used to acquire polychromatic projections of an object being investigated. The measurements obtained by X-ray CT detectors are noisy in reality, especially in spectral CT where the photon number is low in each energy channel. Therefore, some regularization should be applied to obtain a better image quality for this ill-posed problem in spectral CT image reconstruction. Quadratic-based regularizations are not often satisfactory as they blur the edges in the reconstructed images. As a result, different edge-preserving regularization methods have been adopted for reconstructing high quality images in the last decade. In this work, we numerically evaluate the performance of different regularizers in spectral CT, including total variation, non-local means and anisotropic diffusion. The goal is to provide some practical guidance to accurately reconstruct the attenuation distribution in each energy channel of the spectral CT data.

  12. DW MRI at 3.0 T versus FDG PET/CT for detection of malignant pulmonary tumors.

    PubMed

    Zhang, Jian; Cui, Long-Biao; Tang, Xing; Ren, Xin-Ling; Shi, Jie-Ran; Yang, Hai-Nan; Zhang, Yan; Li, Zhi-Kui; Wu, Chang-Gui; Jian, Wen; Zhao, Feng; Ti, Xin-Yu; Yin, Hong

    2014-02-01

    Emerging evidence suggests that diffusion-weighted magnetic resonance imaging (DW MRI) could be useful for tumor detection with N and M staging of lung cancer in place of fluorine 18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). DW MRI at 3.0 T and FDG PET/CT were performed before therapy in 113 patients with pulmonary nodules. Mean apparent diffusion coefficient (ADC), maximal standardized uptake value (SUVmax ) and Ki-67 scores were assessed. Quantitatively, specificity and accuracy of ADC (91.7 and 92.9%, respectively) were significantly higher than those of SUVmax (66.7 and 77.9% respectively, p < 0.05), although sensitivity was not significantly different between them (93.5 and 83.1%, p > 0.05). Qualitatively, sensitivity, specificity and accuracy of DW MRI (96.1, 83.3 and 92.0%, respectively) were also not significantly different from that of FDG PET/CT (88.3, 83.3 and 86.7%, respectively, p > 0.05). Significant negative correlation was found between Ki-67 score and ADC (r = -0.66, p < 0.05), ADC and SUVmax (r = -0.37, p < 0.05), but not between Ki-67 score and SUVmax (r = -0.11, p > 0.05). In conclusion, quantitative and qualitative assessments for detection of malignant pulmonary tumors with DW MRI at 3.0 T are superior to those with FDG PET/CT. Furthermore, ADC could predict the malignancy of lung cancer. © 2013 UICC.

  13. Retinoic acid-induced alveolar cellular growth does not improve function after right pneumonectomy.

    PubMed

    Dane, D Merrill; Yan, Xiao; Tamhane, Rahul M; Johnson, Robert L; Estrera, Aaron S; Hogg, Deborah C; Hogg, Richard T; Hsia, Connie C W

    2004-03-01

    To determine whether all-trans retinoic acid (RA) treatment enhances lung function during compensatory lung growth in fully mature animals, adult male dogs (n = 4) received 2 mg x kg(-1) x day(-1) po RA 4 days/wk beginning the day after right pneumonectomy (R-PNX, 55-58% resection). Litter-matched male R-PNX controls (n = 4) received placebo. After 3 mo, transpulmonary pressure (TPP)-lung volume relationship, diffusing capacities for carbon monoxide and nitric oxide, cardiac output, and septal volume (V(tiss-RB)) were measured under anesthesia by a rebreathing technique at two lung volumes. Lung air and tissue volumes (V(air-CT) and V(tiss-CT)) were also measured from high-resolution computerized tomographic (CT) scans at a constant TPP. In RA-treated dogs compared with controls, TPP-lung volume relationships were similar. Diffusing capacities for carbon monoxide and nitric oxide were significantly impaired at a lower lung volume but similar at a high lung volume. Whereas V(tiss-RB) was significantly lower at both lung volumes in RA-treated animals, V(air-CT) and V(tiss-CT) were not different between groups; results suggest uneven distribution of ventilation consistent with distortion of alveolar geometry and/or altered small airway function induced by RA. We conclude that RA does not improve resting pulmonary function during the early months after R-PNX despite histological evidence of its action in enhancing alveolar cellular growth in the remaining lung.

  14. Clinical spectrum of intrathoracic Castleman disease: a retrospective analysis of 48 cases in a single Chinese hospital.

    PubMed

    Luo, Jin Mei; Li, Shan; Huang, Hui; Cao, Jian; Xu, Kai; Bi, Ya Lan; Feng, Rui E; Huang, Cheng; Qin, Ying Zhi; Xu, Zuo Jun; Xiao, Yi

    2015-04-09

    Thorax is the common place to develop Castleman disease (CD), but there is no systemic clinical analysis for intrathoracic CD. We conducted a retrospective analysis of 48 intrathoracic CD patients with definite pathological diagnosis who were hospitalized between 1992 and 2012 in a Chinese tertiary referral hospital. The study included 16 cases with unicentric CD (UCD) and 32 cases with multicentric CD (MCD). UCD were younger than MCD (30.5y vs 41.6ys, P < 0.05). MCD were more symptomatic (50% vs 96.9%, P < 0.001) and sicker than UCD, including more fever, hepatomegaly and/or splenomegaly and hypoalbuminemia. All of UCD showed solitary mass in various sites and two of them were complicated by small pleural effusion. In the MCD group, their chest CT showed obvious lymphadenopathy in the hilum and/or mediastinum (100%), diffuse parenchymal lung shadows (43.75%), pleural effusion (40.6%), mass in the mediastinum (6.25%) or hilum (3.12%) and bronchiolitis obliterans (BO) (3.12%). Besides LIP-like images, multiple nodules of different size and sites, patchy, ground-glass opacities and consolidation were showed in their chest CT. Surgery were arranged for all UCD for diagnosis and treatment and all were alive. In MCD group, superficial lymph nodes biopsies (21 cases), surgery biopsy (9 cases) and CT-guided percutaneous lung biopsy (2 cases) were performed. Hyaline vascular (HV) variant were more common in the UCD group (75% vs 37.5%, P < 0.05). In MCD group, 28 cases were prescribed with chemotherapy, one refused to receive therapy and the rest three were arranged for regular follow-up. Among MCD, 18 cases was improved, 7 cases was stable, 4 cases lost follow-up and 3 cases died. Intrathoracic MCD was more common than UCD in our hospital. MCD was older, more symptomic and sicker than UCD. HV variant were more common in UCD. All of UCD showed mass in various intrathoracic locations and surgery resection was performed for all and all were alive. Mass, pleural effusion, BO and diffuse pulmonary shadows, including LIP-like images, multiple nodules of different size and sites, patchy, GGO and consolidations were showed in our MCD. Most of MCD cases were arranged with chemotherapy and their prognosis were worse than UCD's.

  15. Prediction of tumor differentiation using sequential PET/CT and MRI in patients with breast cancer.

    PubMed

    Choi, Joon Ho; Lim, Ilhan; Noh, Woo Chul; Kim, Hyun-Ah; Seong, Min-Ki; Jang, Seonah; Seol, Hyesil; Moon, Hansol; Byun, Byung Hyun; Kim, Byung Il; Choi, Chang Woon; Lim, Sang Moo

    2018-05-23

    The aim of this study is to assess tumor differentiation using parameters from sequential positron emission tomography/computed tomography (PET/CT) and magnetic resonance imaging (MRI) in patients with breast cancer. This retrospective study included 78 patients with breast cancer. All patients underwent sequential PET/CT and MRI. For fluorodeoxyglucose (FDG)-PET image analysis, the maximum standardized uptake value (SUV max ) of FDG was assessed at both 1 and 2 h and metabolic tumor volume (MTV) and total lesion glycolysis (TLG). The kinetic analysis of dynamic contrast-enhanced MRI parameters was performed using dynamic enhancement curves. We assessed diffusion-weighted imaging (DWI)-MRI parameters regarding apparent diffusion coefficient (ADC) values. Histologic grades 1 and 2 were classified as low-grade, and grade 3 as high-grade tumor. Forty-five lesions of 78 patients were classified as histologic grade 3, while 26 and 7 lesions were grade 2 and grade 1, respectively. Patients with high-grade tumors showed significantly lower ADC-mean values than patients with low-grade tumors (0.99 ± 0.19 vs.1.12 ± 0.32, p = 0.007). With respect to SUV max 1, MTV2.5, and TLG2.5, patients with high-grade tumors showed higher values than patients with low-grade tumors: SUV max 1 (7.92 ± 4.5 vs.6.19 ± 3.05, p = 0.099), MTV2.5 (7.90 ± 9.32 vs.4.38 ± 5.10, p = 0.095), and TLG2.5 (40.83 ± 59.17 vs.19.66 ± 26.08, p = 0.082). However, other parameters did not reveal significant differences between low-grade and high-grade malignancies. In receiver-operating characteristic (ROC) curve analysis, ADC-mean values showed the highest area under the curve of 0.681 (95%CI 0.566-0.782) for assessing high-grade malignancy. Lower ADC-mean values may predict the poor differentiation of breast cancer among diverse PET-MRI functional parameters.

  16. Bilateral parotitis as the initial presentation of childhood sarcoidosis.

    PubMed

    Banks, Gretchen C; Kirse, Daniel J; Anthony, Evelyn; Bergman, Simon; Shetty, Avinash K

    2013-01-01

    The differential diagnosis of bilateral parotid gland enlargement in children includes infectious, inflammatory, and neoplastic disorders. We present the case of a 13-year-old male who presented with a 5-week history of bilateral parotid swelling. On exam, both parotid glands were nontender, smooth, and diffusely enlarged. He had slightly elevated inflammatory markers, but other lab results were normal. A neck CT revealed symmetric enlargement of the parotid, submandibular, and sublingual glands. A chest CT revealed scattered peripheral pulmonary nodules and bilateral hilar adenopathy. A parotid gland biopsy showed multiple noncaseating granulomas with multinucleated giant cells surrounded by lymphocytes, consistent with the diagnosis of sarcoidosis. Special stains for acid-fast and fungal organisms were negative. Using this illustrative case, we discuss the differential diagnosis of bilateral salivary gland enlargement in children and review the etiology, diagnosis, clinical manifestations, and treatment of pediatric sarcoidosis. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Hybrid SPECT/CT imaging in neurology.

    PubMed

    Ciarmiello, Andrea; Giovannini, Elisabetta; Meniconi, Martina; Cuccurullo, Vincenzo; Gaeta, Maria Chiara

    2014-01-01

    In recent years, the SPECT/CT hybrid modality has led to a rapid development of imaging techniques in nuclear medicine, opening new perspectives for imaging staff and patients as well. However, while, the clinical role of positron emission tomography-computed tomography (PET-CT) is well consolidated, the diffusion and the consequent value of single-photon emission tomography-computed tomography (SPECT-CT) has yet to be weighed, Hence, there is a need for a careful analysis, comparing the "potential" benefits of the hybrid modality with the "established" ones of the standalone machine. The aim of this article is to analyze the impact of this hybrid tool on the diagnosis of diseases of the central nervous system, comparing strengths and weaknesses of both modalities through the use of SWOT analysis.

  18. Medulloblastoma with Atypical Dynamic Imaging Changes: Case Report with Literature Review.

    PubMed

    Song, Shuang-Shuang; Wang, Jian-Hong; Fu, Wei-Wei; Li, Ying; Sui, Qing-Lan; Liu, Xue-Jun

    2017-09-01

    We analyzed a case of medulloblastoma with atypical dynamic imaging changes retrospectively to summarize the atypical magnetic resonance imaging (MRI) features of medulloblastoma by reviewing the literature. An atypical case of medulloblastoma in the cerebellar hemisphere confirmed by pathology was analyzed retrospectively, and the literature about it was reviewed. The radiologic findings of the patient were based on 3 examinations. The first examination showed that the cortex of the bilateral cerebellar hemisphere had diffuse nodular thickening, with a high signal on diffusion-weighted imaging and significant enhancement. Contrast enhancement MRI 1 year later showed the signal of cerebellar hemisphere returned to normal but revealed an enhanced nodule. A reexamination 6 months later showed an irregular mass with a high-density shadow in the cerebellar vermis on CT scan. The T2-weighted image revealed multiple degenerative cysts, and the mass had significant enhancement. The radiologic characteristics of atypical medulloblastomas vary in adults and children. Understanding the radiologic characteristics of medulloblastomas, such as MRI features, age of onset, and location of atypical medulloblastomas, can help improve the diagnosis of medulloblastomas. Copyright © 2017. Published by Elsevier Inc.

  19. Multiphasic modeling of charged solute transport across articular cartilage: Application of multi-zone finite-bath model.

    PubMed

    Arbabi, Vahid; Pouran, Behdad; Weinans, Harrie; Zadpoor, Amir A

    2016-06-14

    Charged and uncharged solutes penetrate through cartilage to maintain the metabolic function of chondrocytes and to possibly restore or further breakdown the cartilage tissue in different stages of osteoarthritis. In this study the transport of charged solutes across the various zones of cartilage was quantified, taken into account the physicochemical interactions between the solute and the cartilage constituents. A multiphasic finite-bath finite element (FE) model was developed to simulate equine cartilage diffusion experiments that used a negatively charged contrast agent (ioxaglate) in combination with serial micro-computed tomography (micro-CT) to measure the diffusion. By comparing the FE model with the experimental data both the diffusion coefficient of ioxaglate and the fixed charge density (FCD) were obtained. In the multiphasic model, cartilage was divided into multiple (three) zones to help understand how diffusion coefficient and FCD vary across cartilage thickness. The direct effects of charged solute-FCD interaction on diffusion were investigated by comparing the diffusion coefficients derived from the multiphasic and biphasic-solute models. We found a relationship between the FCD obtained by the multiphasic model and ioxaglate partitioning obtained from micro-CT experiments. Using our multi-zone multiphasic model, diffusion coefficient of the superficial zone was up to ten-fold higher than that of the middle zone, while the FCD of the middle zone was up to almost two-fold higher than that of the superficial zone. In conclusion, the developed finite-bath multiphasic model provides us with a non-destructive method by which we could obtain both diffusion coefficient and FCD of different cartilage zones. The outcomes of the current work will also help understand how charge of the bath affects the diffusion of a charged molecule and also predict the diffusion behavior of a charged solute across articular cartilage. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Automated segmentation of murine lung tumors in x-ray micro-CT images

    NASA Astrophysics Data System (ADS)

    Swee, Joshua K. Y.; Sheridan, Clare; de Bruin, Elza; Downward, Julian; Lassailly, Francois; Pizarro, Luis

    2014-03-01

    Recent years have seen micro-CT emerge as a means of providing imaging analysis in pre-clinical study, with in-vivo micro-CT having been shown to be particularly applicable to the examination of murine lung tumors. Despite this, existing studies have involved substantial human intervention during the image analysis process, with the use of fully-automated aids found to be almost non-existent. We present a new approach to automate the segmentation of murine lung tumors designed specifically for in-vivo micro-CT-based pre-clinical lung cancer studies that addresses the specific requirements of such study, as well as the limitations human-centric segmentation approaches experience when applied to such micro-CT data. Our approach consists of three distinct stages, and begins by utilizing edge enhancing and vessel enhancing non-linear anisotropic diffusion filters to extract anatomy masks (lung/vessel structure) in a pre-processing stage. Initial candidate detection is then performed through ROI reduction utilizing obtained masks and a two-step automated segmentation approach that aims to extract all disconnected objects within the ROI, and consists of Otsu thresholding, mathematical morphology and marker-driven watershed. False positive reduction is finally performed on initial candidates through random-forest-driven classification using the shape, intensity, and spatial features of candidates. We provide validation of our approach using data from an associated lung cancer study, showing favorable results both in terms of detection (sensitivity=86%, specificity=89%) and structural recovery (Dice Similarity=0.88) when compared against manual specialist annotation.

  1. Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Nan-Jie; Wong, Chun-Sing, E-mail: drcswong@gmail.com; Chu, Yiu-Ching

    2013-10-01

    Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using themore » proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.« less

  2. Deposition in the distal parts of the bovine respiratory tract: assessment of equipment suitable for drug inhalation.

    PubMed

    Genicot, B; Votion, D; Munsters, K; Close, R; Lindsey, J K; Lekeux, P

    1996-03-30

    The efficiency of equipment suitable for the inhalation of drugs by calves was assessed in six animals which inhaled radioisotopically labelled particles while suffering from reversible diffuse bronchoconstriction induced experimentally with 5-hydroxytryptamine and while they were breathing normally. Respiratory rates and data from pulmonary function tests and scintiscans were recorded during both investigations. After the first investigation, a mean (se) wash-out period of 9.8 (3.2) days was allowed. Under diffuse bronchoconstriction, the respiratory rate, the oscillatory resistance and the compliance of the respiratory system reached 282.1 (22.0), 161.1 (10.8) and 68.8 (2.7) per cent of their respective baseline values. When the calves were breathing normally these parameters did not change over time. The ratios (Cp/Ct) of the counts of gamma-disintegrations in the peripheral part (Cp) of the lungs and in the total lung area (Ct) were not significantly different when comparing the results from the two investigations. The ratios of Cp/Ct in the left lungs did not differ significantly from those in the right lungs.

  3. IgG4-Related Disease of the Thyroid Gland Requiring Emergent Total Thyroidectomy: A Case Report.

    PubMed

    Zhao, Zitong; Lee, Yu Jin; Zheng, Shuwei; Khor, Li Yan; Lim, Kok Hing

    2018-05-31

    IgG4-related disease of the thyroid gland is a recently recognized subtype of thyroiditis, often with rapid progression requiring surgical treatment. It is considered as a spectrum of disease varying from early IgG4-related Hashimoto's thyroiditis (HT) pattern to late fibrosing HT or Riedel's thyroiditis patterns. Here, we report a 47-year-old Malay woman presenting with progressively painless neck swelling over 3 years and subclinical hypothyroidism. Computed tomography (CT) scan revealed diffuse thyroid enlargement (up to 13 cm) with retrosternal extension and without regional lymphadenopathy. Fine needle aspiration of the thyroid showed a limited number of follicular epithelial cell groups with widespread Hurthle cell change and scanty background colloid, but no evidence of lymphocytosis. The cytologic features fell into the category of 'atypia of undetermined significance'. Subsequently, the patient developed hypercapnic respiratory failure secondary to extrinsic upper airway compression by the thyroid mass and underwent emergent total thyroidectomy. Histology of the thyroid showed diffuse dense lymphoplasmacytic infiltrate and fibrosis. Follicular cells exhibited reactive nuclear features and some Hurthle cell change. IgG4+ plasma cells were over 40/high power field while overall IgG4/IgG ratio was above 50%. The overall features suggest the diagnosis of IgG4-related disease of the thyroid gland in the form of IgG4-related HT. Post-surgery, the patient was found to have markedly elevated serum IgG4 concentration but PET/CT did not show significant increased fludeoxyglucose uptake in other areas. Her recovery was complicated by a ventilator-associated pneumonia with empyema, limiting early use of corticosteroids for treatment of IgG4-related disease.

  4. Is 18F-FDG PET/CT useful for distinguishing between primary thyroid lymphoma and chronic thyroiditis?

    PubMed

    Nakadate, Masashi; Yoshida, Katsuya; Ishii, Akihiro; Koizumi, Masayuki; Tochigi, Naobumi; Suzuki, Yoshio; Ryu, Yoshiharu; Nakagawa, Tassei; Umehara, Isao; Shibuya, Hitoshi

    2013-09-01

    This study aims to investigate the usefulness of (18)F-FDG PET/CT for distinguishing between primary thyroid lymphoma (PTL) and chronic thyroiditis. We retrospectively reviewed the data of 196 patients with diffuse (18)F-FDG uptake of the thyroid gland and enrolled patients who were diagnosed as having PTL or chronic thyroiditis based on the medical records, pathological findings, and laboratory data. The enrolled patients comprised 10 PTL patients (M/F = 4:6) and 51 chronic thyroiditis patients (M/F = 8:43). Images had been acquired on a PET/CT scanner at 100 minutes after intravenous injection of (18)F-FDG. The PTL group consisted of 7 patients with diffuse large B-cell lymphoma (DLBCL) and 3 with mucosa-associated lymphoid tissue (MALT) lymphoma. The maximum standardized uptake value (SUV(max)) was significantly higher in the PTL group than that in the chronic thyroiditis group (25.3 ± 8.0 and 7.4 ± 3.2, P < 0.001). On the other hand, the CT density (Hounsfield unit: HU) was significantly lower in the PTL group than that in the chronic thyroiditis group (46.1 ± 7.0 HU and 62.1 ± 6.9 HU, P < 0.001). Within the PTL group, the SUV(max) was significantly higher in the cases of DLBCL than in those of MALT lymphoma (29.0 ± 6.4 and 16.7 ± 2.3, P = 0.017). The SUV(max) was significantly higher and the CT density was significantly lower in PTL as compared with those in chronic thyroiditis. Thus, (18)F-FDG PET/CT may be useful for distinguishing between PTL and chronic thyroiditis.

  5. Utility of the PET-CT in the evaluation of early response to treatment in the diffuse large B-cell lymphoma. Preliminary results.

    PubMed

    Cortés Romera, M; Gámez Cenzano, C; Caresia Aróztegui, A P; Martín-Comín, J; González-Barca, E; Ricart Brulles, Y; Palacios Abufón, A; Robles Barba, J; Rodríguez-Bel, L; Rossi Seoane, S; Fernández de Sevilla, A

    2012-01-01

    To assess the role of FDG-PET/CT performed after the first cycles of chemotherapy in the prediction of response to treatment in patients with diffuse large B-cell lymphoma. Twenty patients (mean age: 48 years) were included, 16 initial staging and 4 relapse. All patients underwent PET/CT at 3 times: 1) Baseline, 2) After 1-3 cycles of chemotherapy (early response assessment), and 3) End of treatment (evaluation of final response). Early PET/CT findings were correlated to the end-treatment PET/CT and follow-up. The evaluation of the response was established according to the decrease in uptake of the lesions (SUVmax). In the early assessment, a good response indicator (GRI) was obtained when the lesion disappeared or had more than 50% reduction in SUVmax. At the end of the treatment, a complete metabolic response (CMR) was determined in negative PET scans. Follow-up was superior to 19 months and final outcome was established as progression/relapse or no evidence of disease (NED). At the early treatment evaluation, 16/16 patients of initial staging (100%) and 2/4 of relapse (50%) achieved GRI. At the end of treatment evaluation, 14/16 patients of initial staging with GRI achieved CMR and 1/16 PMR: 14 were alive with NED in the follow-up while 1 relapsed. In the second group, 2/2 patients with GRI achieved CMR (100%): 1 continued with NED in the follow-up and another relapsed. FDG-PET/CT after the first cycles of chemotherapy is useful to monitor treatment due to its high negative predictive value (87.5%), using it to modify treatment early in the non-responders. Copyright © 2011 Elsevier España, S.L. y SEMNIM. All rights reserved.

  6. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for rapid, high-resolution, 3-D imaging of metazoan soft tissues.

    PubMed

    Gignac, Paul M; Kley, Nathan J; Clarke, Julia A; Colbert, Matthew W; Morhardt, Ashley C; Cerio, Donald; Cost, Ian N; Cox, Philip G; Daza, Juan D; Early, Catherine M; Echols, M Scott; Henkelman, R Mark; Herdina, A Nele; Holliday, Casey M; Li, Zhiheng; Mahlow, Kristin; Merchant, Samer; Müller, Johannes; Orsbon, Courtney P; Paluh, Daniel J; Thies, Monte L; Tsai, Henry P; Witmer, Lawrence M

    2016-06-01

    Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward. © 2016 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  7. The Potential for Conservation Tillage Adoption in the San Joaquin Valley, California: A Qualitative Study of Farmer Perspectives and Opportunities for Extension

    PubMed Central

    Bossange, Anne V.; Knudson, Kandace M.; Shrestha, Anil; Harben, Ronald; Mitchell, Jeffrey P.

    2016-01-01

    Conservation tillage (CT) systems have a number of potential benefits including lower crop production costs and the ability to reduce soil erosion that have made them common in several regions of the world. Although CT systems have been researched and successfully implemented on some farms in California’s San Joaquin Valley (SJV), overall adoption is low and the reasons for the region’s comparatively low rates of adoption are not known. In 2011, we conducted written surveys and interviews with SJV farmers to identify characteristics of farmers who adopt or do not adopt CT, to determine reasons for non-adoption of CT, and to learn how successful CT adoption takes place in the SJV. We found that a universally acceptable definition of CT needs to be developed in order for effective research, outreach and communication on CT. Our research, which examined CT adoption within the expected progression of the diffusion of innovation model, suggested that larger and less diverse farms were more likely to use CT. Most farmers expressed transition to CT as a continuous learning process. Further, we conclude that gaining meaningful experience with CT practices by researchers in the local context is also a large component of successful adoption. PMID:27907196

  8. Optimizing Soft Tissue Management and Spacer Design in Segmental Bone Defects

    DTIC Science & Technology

    2014-10-01

    the time of the “Pre-Procedure”. Autogenous Cancellous Bone Graft (ACBG harvested from the sternum at the time of the treatment surgery is used as...will receive more specialized training and orientation to microCT analysis, both on a theoretical and practical level. He will work with raw CT...adjacent to the PMMA) composed of mononuclear cells and exhibited extensive, diffuse fibrous connective tissue.  Performed histology on goat autogenous

  9. The Potential for an Enhanced Role for MRI in Radiation-therapy Treatment Planning

    PubMed Central

    Metcalfe, P.; Liney, G. P.; Holloway, L.; Walker, A.; Barton, M.; Delaney, G. P.; Vinod, S.; Tomé, W.

    2013-01-01

    The exquisite soft-tissue contrast of magnetic resonance imaging (MRI) has meant that the technique is having an increasing role in contouring the gross tumor volume (GTV) and organs at risk (OAR) in radiation therapy treatment planning systems (TPS). MRI-planning scans from diagnostic MRI scanners are currently incorporated into the planning process by being registered to CT data. The soft-tissue data from the MRI provides target outline guidance and the CT provides a solid geometric and electron density map for accurate dose calculation on the TPS computer. There is increasing interest in MRI machine placement in radiotherapy clinics as an adjunct to CT simulators. Most vendors now offer 70 cm bores with flat couch inserts and specialised RF coil designs. We would refer to these devices as MR-simulators. There is also research into the future application of MR-simulators independent of CT and as in-room image-guidance devices. It is within the background of this increased interest in the utility of MRI in radiotherapy treatment planning that this paper is couched. The paper outlines publications that deal with standard MRI sequences used in current clinical practice. It then discusses the potential for using processed functional diffusion maps (fDM) derived from diffusion weighted image sequences in tracking tumor activity and tumor recurrence. Next, this paper reviews publications that describe the use of MRI in patient-management applications that may, in turn, be relevant to radiotherapy treatment planning. The review briefly discusses the concepts behind functional techniques such as dynamic contrast enhanced (DCE), diffusion-weighted (DW) MRI sequences and magnetic resonance spectroscopic imaging (MRSI). Significant applications of MR are discussed in terms of the following treatment sites: brain, head and neck, breast, lung, prostate and cervix. While not yet routine, the use of apparent diffusion coefficient (ADC) map analysis indicates an exciting future application for functional MRI. Although DW-MRI has not yet been routinely used in boost adaptive techniques, it is being assessed in cohort studies for sub-volume boosting in prostate tumors. PMID:23617289

  10. (18)F-FDG PET/CT, cytoreductive surgery and intraperitoneal chemohyperthermia for the therapeutic management in peritoneal carcinomatosis: A pilot study.

    PubMed

    Cistaro, A; Cucinotta, M; Cassalia, L; Priola, A; Priola, S; Pappalardo, M; Coppolino, P; De Simone, M; Quartuccio, N

    2016-01-01

    Peritoneal carcinomatosis is a common evolution of neoplasms and the terminal stage of disease. A new therapeutic technique, based on the total surgical removal of peritoneal lesions (peritonectomy procedure - PP) combined with the intraperitoneal chemohyperthermia (IPCH), has been developed. Proper patient selection is mandatory for optimizing the results of treatment. The aim of this study was to investigate the role of [(18)F]fluoro-2-deoxy-d-glucose Positron Emission Tomography/Computed Tomography ((18)F-FDG PET/CT) in patients with peritoneal carcinosis selected to undergo PP and IPCH. Furthermore, we aimed to identify characteristic patterns of abdominal(18)F-FDG uptake and to correlate these patterns with available anatomic findings after surgery. Patients with either histologically confirmed peritoneal carcinosis or suspected upon clinical follow-up and/or imaging findings were prospectively submitted to pre-surgery (18)F-FDG PET/CT scan. Only those patients without evidence of extra-peritoneal metastases at PET/CT scan were treated with PP and IPCH. 11 patients with peritoneal carcinomatosis (5 colorectal, 4 ovarian, 1 pancreatic) and 1 unknown primitive cancer, were eligible for the study. In all cases PET/CT scan showed multiple peritoneal implants. In 6 out of 11 cases (54%) metastases were evidenced by (18)F-FDG PET/CT: 2 cases with liver metastases; 1 case with bone metastases; 3 patients with lymph-node lesions. Two distinct imaging patterns, with focal or diffuse increased (18)F-FDG uptake, were recognized. PP+IPCH of patients selected by (18)F-FDG PET/CT seems to be safe and feasible. PET/CT scan appears as a reliable tool for the detection, characterization of peritoneal implants with potential impact in the therapeutic management of these patients. Copyright © 2016 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  11. Medipix-based Spectral Micro-CT.

    PubMed

    Yu, Hengyong; Xu, Qiong; He, Peng; Bennett, James; Amir, Raja; Dobbs, Bruce; Mou, Xuanqin; Wei, Biao; Butler, Anthony; Butler, Phillip; Wang, Ge

    2012-12-01

    Since Hounsfield's Nobel Prize winning breakthrough decades ago, X-ray CT has been widely applied in the clinical and preclinical applications - producing a huge number of tomographic gray-scale images. However, these images are often insufficient to distinguish crucial differences needed for diagnosis. They have poor soft tissue contrast due to inherent photon-count issues, involving high radiation dose. By physics, the X-ray spectrum is polychromatic, and it is now feasible to obtain multi-energy, spectral, or true-color, CT images. Such spectral images promise powerful new diagnostic information. The emerging Medipix technology promises energy-sensitive, high-resolution, accurate and rapid X-ray detection. In this paper, we will review the recent progress of Medipix-based spectral micro-CT with the emphasis on the results obtained by our team. It includes the state- of-the-art Medipix detector, the system and method of a commercial MARS (Medipix All Resolution System) spectral micro-CT, and the design and color diffusion of a hybrid spectral micro-CT.

  12. An Experimental and Finite Element Protocol to Investigate the Transport of Neutral and Charged Solutes across Articular Cartilage.

    PubMed

    Arbabi, Vahid; Pouran, Behdad; Zadpoor, Amir A; Weinans, Harrie

    2017-04-23

    Osteoarthritis (OA) is a debilitating disease that is associated with degeneration of articular cartilage and subchondral bone. Degeneration of articular cartilage impairs its load-bearing function substantially as it experiences tremendous chemical degradation, i.e. proteoglycan loss and collagen fibril disruption. One promising way to investigate chemical damage mechanisms during OA is to expose the cartilage specimens to an external solute and monitor the diffusion of the molecules. The degree of cartilage damage (i.e. concentration and configuration of essential macromolecules) is associated with collisional energy loss of external solutes while moving across articular cartilage creates different diffusion characteristics compared to healthy cartilage. In this study, we introduce a protocol, which consists of several steps and is based on previously developed experimental micro-Computed Tomography (micro-CT) and finite element modeling. The transport of charged and uncharged iodinated molecules is first recorded using micro-CT, which is followed by applying biphasic-solute and multiphasic finite element models to obtain diffusion coefficients and fixed charge densities across cartilage zones.

  13. Computer aided segmentation of kidneys using locally shape constrained deformable models on CT images

    NASA Astrophysics Data System (ADS)

    Erdt, Marius; Sakas, Georgios

    2010-03-01

    This work presents a novel approach for model based segmentation of the kidney in images acquired by Computed Tomography (CT). The developed computer aided segmentation system is expected to support computer aided diagnosis and operation planning. We have developed a deformable model based approach based on local shape constraints that prevents the model from deforming into neighboring structures while allowing the global shape to adapt freely to the data. Those local constraints are derived from the anatomical structure of the kidney and the presence and appearance of neighboring organs. The adaptation process is guided by a rule-based deformation logic in order to improve the robustness of the segmentation in areas of diffuse organ boundaries. Our work flow consists of two steps: 1.) a user guided positioning and 2.) an automatic model adaptation using affine and free form deformation in order to robustly extract the kidney. In cases which show pronounced pathologies, the system also offers real time mesh editing tools for a quick refinement of the segmentation result. Evaluation results based on 30 clinical cases using CT data sets show an average dice correlation coefficient of 93% compared to the ground truth. The results are therefore in most cases comparable to manual delineation. Computation times of the automatic adaptation step are lower than 6 seconds which makes the proposed system suitable for an application in clinical practice.

  14. Characterization of the Structure and Intermolecular Interactions between the Connexin 32 Carboxyl-terminal Domain and the Protein Partners Synapse-associated Protein 97 and Calmodulin*

    PubMed Central

    Stauch, Kelly; Kieken, Fabien; Sorgen, Paul

    2012-01-01

    In Schwann cells, connexin 32 (Cx32) can oligomerize to form intracellular gap junction channels facilitating a shorter pathway for metabolite diffusion across the layers of the myelin sheath. The mechanisms of Cx32 intracellular channel regulation have not been clearly defined. However, Ca2+, pH, and the phosphorylation state can regulate Cx32 gap junction channels, in addition to the direct interaction of protein partners with the carboxyl-terminal (CT) domain. In this study, we used different biophysical methods to determine the structure and characterize the interaction of the Cx32CT domain with the protein partners synapse-associated protein 97 (SAP97) and calmodulin (CaM). Our results revealed that the Cx32CT is an intrinsically disordered protein that becomes α-helical upon binding CaM. We identified the GUK domain as the minimal SAP97 region necessary for the Cx32CT interaction. The Cx32CT residues affected by the binding of CaM and the SAP97 GUK domain were determined as well as the dissociation constants for these interactions. We characterized three Cx32CT Charcot-Marie-Tooth disease mutants (R219H, R230C, and F235C) and identified that whereas they all formed functional channels, they all showed reduced binding affinity for SAP97 and CaM. Additionally, we report that in RT4-D6P2T rat schwannoma cells, Cx32 is differentially phosphorylated and exists in a complex with SAP97 and CaM. Our studies support the importance of protein-protein interactions in the regulation of Cx32 gap junction channels and myelin homeostasis. PMID:22718765

  15. Postthrombolysis hemorrhage risk is affected by stroke assessment bias between hemispheres

    PubMed Central

    Singer, O.C.; Gotzler, B.; Vatankhah, B.; Boy, S.; Fiehler, J.; Lansberg, M.G.; Albers, G.W.; Kastrup, A.; Rovira, A.; Gass, A.; Rosso, C.; Derex, L.; Kim, J.S.; Heuschmann, P.

    2011-01-01

    Objective: Stroke symptoms in right hemispheric stroke tend to be underestimated in clinical assessment scales, resulting in greater infarct volumes in right as compared to left hemispheric strokes despite similar clinical stroke severity. We hypothesized that patients with right hemispheric nonlacunar stroke are at higher risk for secondary intracerebral hemorrhage after thrombolysis despite similar stroke severity. Methods: We analyzed data of 2 stroke cohorts with CT-based and MRI-based imaging before thrombolysis. Initial stroke severity was measured with the NIH Stroke Scale (NIHSS). Lacunar strokes were excluded through either the presence of cortical symptoms (CT cohort) or restriction to patients with prestroke diffusion-weighted imaging (DWI) lesion size >3.75 mL (MRI cohort). Probabilities of having a parenchymal hematoma were determined using multivariate logistic regression. Results: A total of 392 patients in the CT cohort and 400 patients in the MRI cohort were evaluated. Although NIHSS scores were similar in strokes of both hemispheres (median NIHSS: CT: 15 vs 13, MRI: 14 vs 16), the frequencies of parenchymal hematoma were higher in right hemispheric compared to left hemispheric strokes (CT: 12.4% vs 5.7%, MRI: 10.4% vs 6.8%). After adjustment for potential confounders (but not pretreatment lesion volume), the probability of parenchymal hematoma was higher in right hemispheric nonlacunar strokes (CT: odds ratio [OR] 2.3; 95% confidence interval [CI] 1.08–4.89; p = 0.032) and showed a borderline significant effect in the MRI cohort (OR 2.1; 95% CI 0.98–4.49; p = 0.057). Adjustment for pretreatment DWI lesion size eliminated hemispheric differences in hemorrhage risk. Conclusions: Higher hemorrhage rates in right hemispheric nonlacunar strokes despite similar stroke severity may be caused by clinical underestimation of the proportion of tissue at bleeding risk. PMID:21248275

  16. Investigating Phase-Change-Induced Flow in Gas Diffusion Layers in Fuel Cells with X-ray Computed Tomography

    DOE PAGES

    Shum, Andrew D.; Parkinson, Dilworth Y.; Xiao, Xianghui; ...

    2017-10-07

    The performance of polymer-electrolyte fuel cells is heavily dependent on proper management of liquid water. One particular reason is that liquid water can collect in the gas diffusion layers (GDLs) blocking the reactant flow to the catalyst layer. This results in increased mass-transport losses. At higher temperatures, evaporation of water becomes a dominant water-removal mechanism and specifically phase-change-induced (PCI) flow is present due to thermal gradients. This study used synchrotron based micro X-ray computed tomography (CT) to visualize and quantify the water distribution within gas diffusion layers subject to a thermal gradient. Plotting saturation as a function of through-plane distancemore » quantitatively shows water redistribution, where water evaporates at hotter locations and condenses in colder locations. The morphology of the 2 GDLs on the micro-scale, as well as evaporating water clusters, are resolved, indicating that the GDL voids are slightly prolate, whereas water clusters are oblate. From the mean radii of water distributions and visual inspection, it is observed that larger water clusters evaporate faster than smaller ones.« less

  17. Automatic segmentation of the liver using multi-planar anatomy and deformable surface model in abdominal contrast-enhanced CT images

    NASA Astrophysics Data System (ADS)

    Jang, Yujin; Hong, Helen; Chung, Jin Wook; Yoon, Young Ho

    2012-02-01

    We propose an effective technique for the extraction of liver boundary based on multi-planar anatomy and deformable surface model in abdominal contrast-enhanced CT images. Our method is composed of four main steps. First, for extracting an optimal volume circumscribing a liver, lower and side boundaries are defined by positional information of pelvis and rib. An upper boundary is defined by separating the lungs and heart from CT images. Second, for extracting an initial liver volume, optimal liver volume is smoothed by anisotropic diffusion filtering and is segmented using adaptively selected threshold value. Third, for removing neighbor organs from initial liver volume, morphological opening and connected component labeling are applied to multiple planes. Finally, for refining the liver boundaries, deformable surface model is applied to a posterior liver surface and missing left robe in previous step. Then, probability summation map is generated by calculating regional information of the segmented liver in coronal plane, which is used for restoring the inaccurate liver boundaries. Experimental results show that our segmentation method can accurately extract liver boundaries without leakage to neighbor organs in spite of various liver shape and ambiguous boundary.

  18. [A Case of Aphasia after Neck Clipping of a Ruptured Aneurysm at the Origin of the Duplicated Middle Cerebral Artery].

    PubMed

    Miyoshi, Hiroyuki; Migita, Keisuke; Kumano, Kiyoshi; Hashimoto, Naomi; Toyota, Akihiro

    2016-11-01

    We report a case of aphasia after neck clipping of a ruptured aneurysm at the origin of the duplicated middle cerebral artery(DMCA). A 60-year-old woman had a sudden onset of headache and nausea. A computed tomography(CT)scan revealed diffuse subarachnoid hemorrhage. Head three-dimensional CT angiography(3D-CTA)showed a left DMCA with a saccular aneurysm at the origin. She became aphasic on the third day after aneurysmal neck clipping. A CT scan revealed a low-density area in the anterior portion of the left temporal lobe, which is perfused by the DMCA. The DMCA was patent on 3D-CTA, but the angle between the ICA and the DMCA changed steep. It is suspected that the clip changed the branching angle at the DMCA origin, which may have led to decreased blood flow in the DMCA. She received linguistic rehabilitation for dysnomia and was discharged with slight difficulty in naming objects. Six months later, she recovered from the aphasia. One year later, the DMCA was patent on 3D-CTA. We should pay attention to ischemic complications in clipping because DMCAs are easily deformed.

  19. Temperature effects on diffusion coefficient for 6-gingerol and 6-shogaol in subcritical water extraction

    NASA Astrophysics Data System (ADS)

    Ilia Anisa, Nor; Azian, Noor; Sharizan, Mohd; Iwai, Yoshio

    2014-04-01

    6-gingerol and 6-shogaol are the main constituents as anti-inflammatory or bioactive compounds from zingiber officinale Roscoe. These bioactive compounds have been proven for inflammatory disease, antioxidatives and anticancer. The effect of temperature on diffusion coefficient for 6-gingerol and 6-shogaol were studied in subcritical water extraction. The diffusion coefficient was determined by Fick's second law. By neglecting external mass transfer and solid particle in spherical form, a linear portion of Ln (1-(Ct/Co)) versus time was plotted in determining the diffusion coefficient. 6-gingerol obtained the higher yield at 130°C with diffusion coefficient of 8.582x10-11 m2/s whilst for 6-shogaol, the higher yield and diffusion coefficient at 170°C and 19.417 × 10-11 m2/s.

  20. A Novel Imaging Technique (X-Map) to Identify Acute Ischemic Lesions Using Noncontrast Dual-Energy Computed Tomography.

    PubMed

    Noguchi, Kyo; Itoh, Toshihide; Naruto, Norihito; Takashima, Shutaro; Tanaka, Kortaro; Kuroda, Satoshi

    2017-01-01

    We evaluated whether X-map, a novel imaging technique, can visualize ischemic lesions within 20 hours after the onset in patients with acute ischemic stroke, using noncontrast dual-energy computed tomography (DECT). Six patients with acute ischemic stroke were included in this study. Noncontrast head DECT scans were acquired with 2 X-ray tubes operated at 80 kV and Sn150 kV between 32 minutes and 20 hours after the onset. Using these DECT scans, the X-map was reconstructed based on 3-material decomposition and compared with a simulated standard (120 kV) computed tomography (CT) and diffusion-weighted imaging (DWI). The X-map showed more sensitivity to identify the lesions as an area of lower attenuation value than a simulated standard CT in all 6 patients. The lesions on the X-map correlated well with those on DWI. In 3 of 6 patients, the X-map detected a transient decrease in the attenuation value in the peri-infarct area within 1 day after the onset. The X-map is a powerful tool to supplement a simulated standard CT and characterize acute ischemic lesions. However, the X-map cannot replace a simulated standard CT to diagnose acute cerebral infarction. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Characterization of transport phenomena in porous transport layers using X-ray microtomography

    NASA Astrophysics Data System (ADS)

    Hasanpour, S.; Hoorfar, M.; Phillion, A. B.

    2017-06-01

    Among different methods available for estimating the transport properties of porous transport layers (PTLs) of polymer electrolyte membrane fuel cells, X-ray micro computed tomography (X-μCT) imaging in combination with image-based numerical simulation has been recognized as a viable tool. In this study, four commercially-available single-layer and dual-layer PTLs are analyzed using this method in order to compare and contrast transport properties between different PTLs, as well as the variability within a single sheet. Complete transport property datasets are created for each PTL. The simulation predictions indicate that PTLs with high porosity show considerable variability in permeability and effective diffusivity, while PTLs with low porosity do not. Furthermore, it is seen that the Tomadakis-Sotirchos (TS) analytical expressions for porous media match the image-based simulations when porosity is relatively low but predict higher permeability and effective diffusivity for porosity values greater than 80%. Finally, the simulations show that cracks within MPL of dual-layer PTLs have a significant effect on the overall permeability and effective diffusivity of the PTLs. This must be considered when estimating the transport properties of dual-layer PTLs. These findings can be used to improve macro-scale models of product and reactant transport within fuel cells, and ultimately, fuel cell efficiency.

  2. High Resolution Diffusion Tensor Imaging of Cortical-Subcortical White Matter Tracts in TBI

    DTIC Science & Technology

    2009-10-01

    other words, CT perfusion is a change in CT intensity (or Hounsfield Unit , HU) over time following a bolus of iodine based contrast agent. Although...E-Mail: little@uic.edu 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT...estimates of the eigenvalues and decrease the signal-to-noise ratio, a background noise level of 125 (MR Units ) was applied prior to calculation of

  3. Computer tomographic evaluation of digestive tract non-Hodgkin lymphomas.

    PubMed

    Lupescu, Ioana G; Grasu, Mugur; Goldis, Gheorghe; Popa, Gelu; Gheorghe, Cristian; Vasilescu, Catalin; Moicean, Andreea; Herlea, Vlad; Georgescu, Serban A

    2007-09-01

    Computer Tomographic (CT) study is crucial for defining distribution, characteristics and staging of primary gastrointestinal lymphomas. The presence of multifocal sites, the wall thickening with diffuse infiltration of the affected gastrointestinal (GI) segment in association with regional adenopathies, permit the orientation of the CT diagnosis for primary GI lymphomas. The gold standard for diagnosis remains, in all cases of digestive tract non-Hodgkin lymphomas (NHL), the histological examination, which allows a tissue diagnosis, performed preferably by transmural biopsy.

  4. Hyperostotic Esthesioneuroblastoma: Rare Variant and Fibrous Dysplasia Mimicker

    PubMed Central

    Knott, Phillip Daniel

    2014-01-01

    A 65-year-old male presented with a 3-year history of orbital symptoms. An imaging-based diagnosis of fibrous dysplasia involving the skull base was made at another institution. CT showed a diffuse sinonasal mass and ground-glass appearance of the bones of the anterior skull base with bony defects and mucocele formation. MRI demonstrated an accompanying intracranial and orbital rind of soft tissue mass along the hyperostotic bones. FDG-PET showed corresponding intense hypermetabolism. Small cysts were observed at the tumor-brain interface. Biopsy revealed esthesioneuroblastoma with bone infiltration that is compatible with the hyperostotic variant of esthesioneuroblastoma. There are a few cases of hyperostotic esthesioneuroblastoma reported in the literature. PMID:24497807

  5. A Demons algorithm for image registration with locally adaptive regularization.

    PubMed

    Cahill, Nathan D; Noble, J Alison; Hawkes, David J

    2009-01-01

    Thirion's Demons is a popular algorithm for nonrigid image registration because of its linear computational complexity and ease of implementation. It approximately solves the diffusion registration problem by successively estimating force vectors that drive the deformation toward alignment and smoothing the force vectors by Gaussian convolution. In this article, we show how the Demons algorithm can be generalized to allow image-driven locally adaptive regularization in a manner that preserves both the linear complexity and ease of implementation of the original Demons algorithm. We show that the proposed algorithm exhibits lower target registration error and requires less computational effort than the original Demons algorithm on the registration of serial chest CT scans of patients with lung nodules.

  6. A genetic polymorphism in TOX3 is associated with survival of gastric cancer in a Chinese population.

    PubMed

    Zhang, Xiaojing; Zhu, Haixia; Wu, Xiaomin; Wang, Meilin; Gu, Dongying; Gong, Weida; Xu, Zhi; Tan, Yongfei; Gong, Yongling; Zhou, Jianwei; Tang, Cuiju; Tong, Na; Chen, Jinfei; Zhang, Zhengdong

    2013-01-01

    Recently, genetic polymorphism (rs3803662C>T) in TOX3 was reported to induce the risk of breast cancer. In this study, we hypothesized that rs3803662 could influence gastric cancer survival outcomes. With multiplex SNaPshot method, we genotyped TOX3 rs3803662 in 880 gastric patients with surgical resection. The association between genotype and survival outcomes was performed by the Kaplan-Meier method, Cox regression analysis models and the log-rank test. There was no association in the analyses of rs3803662 and survival of gastric cancer. However, the stratified analysis by histology showed that rs3803662 CT/TT genotype was associated with a significantly better survival for diffuse-type gastric cancer (log-rank p = 0.030, hazard ratio [HR]  = 0.67, 95% confidence interval [CI]  = 0.46-0.96), than the CC genotype. In addition, this favorable effect was especially obvious among gastric cancer patients with tumor size >5 cm, T3 and T4 depth of invasion, lymph node metastasis, no drinking, no distant metastasis, no chemotherapy and gastric cardia cancer. TOX3 rs3803662 might play an important role in the prognostic outcome and treatment of gastric cancer, especially perhaps further help in explaining the reduced risk of death associated with diffuse-type gastric cancer.

  7. Impact of soil structure heterogeneity on the degradation of organic pollutants at the centimeter scale : 3D Modeling using graph based method

    NASA Astrophysics Data System (ADS)

    Sinclair Yemini, Francis; Chenu, Claire; Monga, Olivier; Vieuble Gonond, Laure; Juarez, Sabrina; Pihneiro, Marc; otten, Wilfred; Garnier, Patricia

    2014-05-01

    Contaminant degradation by microorganisms is very variable in soils because of the very heterogeneous spatial relationship of contaminant/degraders. Repacked Soil columns were carried out to study the degradation of 2,4D pesticide labelled with C14 for different scenarios of microorganisms and pesticide initial location. Measurements of global C14-CO2 emission and C14 distribution in the soil column showed that the initial location play a crucial rule on the dissipation of the pollutant. Experiments were simulated using a 3D model able to model microbial degradation and substrate diffusion between aggregates by considering explicitly the 3D structure of soil from CT images. The initial version of the model (Monga et al., 2008) was improved in order to simulate diffusion in samples of large size. Partial differential equations were implemented using freefem++ solver. The model simulates properly the dynamics of 2,4D in the column for the different initial situations. CT images of the same soil but using undisturbed structure instead of repacked aggregates were also carried out. Significant differences of the simulated results were observed between the repacked and the undisturbed soil. The conclusion of our work is that the heterogeneity of the soil structure and location of pollutants and decomposers has a very strong influence on the dissipation of pollutants.

  8. Processing of CT images for analysis of diffuse lung disease in the lung tissue research consortium

    NASA Astrophysics Data System (ADS)

    Karwoski, Ronald A.; Bartholmai, Brian; Zavaletta, Vanessa A.; Holmes, David; Robb, Richard A.

    2008-03-01

    The goal of Lung Tissue Resource Consortium (LTRC) is to improve the management of diffuse lung diseases through a better understanding of the biology of Chronic Obstructive Pulmonary Disease (COPD) and fibrotic interstitial lung disease (ILD) including Idiopathic Pulmonary Fibrosis (IPF). Participants are subjected to a battery of tests including tissue biopsies, physiologic testing, clinical history reporting, and CT scanning of the chest. The LTRC is a repository from which investigators can request tissue specimens and test results as well as semi-quantitative radiology reports, pathology reports, and automated quantitative image analysis results from the CT scan data performed by the LTRC core laboratories. The LTRC Radiology Core Laboratory (RCL), in conjunction with the Biomedical Imaging Resource (BIR), has developed novel processing methods for comprehensive characterization of pulmonary processes on volumetric high-resolution CT scans to quantify how these diseases manifest in radiographic images. Specifically, the RCL has implemented a semi-automated method for segmenting the anatomical regions of the lungs and airways. In these anatomic regions, automated quantification of pathologic features of disease including emphysema volumes and tissue classification are performed using both threshold techniques and advanced texture measures to determine the extent and location of emphysema, ground glass opacities, "honeycombing" (HC) and "irregular linear" or "reticular" pulmonary infiltrates and normal lung. Wall thickness measurements of the trachea, and its branches to the 3 rd and limited 4 th order are also computed. The methods for processing, segmentation and quantification are described. The results are reviewed and verified by an expert radiologist following processing and stored in the public LTRC database for use by pulmonary researchers. To date, over 1200 CT scans have been processed by the RCL and the LTRC project is on target for recruitment of the 2200 patients with 1800 CT scans in the repository for the 5-year effort. Ongoing analysis of the results in the LTRC database by the LTRC participating institutions and outside investigators are underway to look at the clinical and physiological significance of the imaging features of these diseases and correlate these findings with quality of life and other important prognostic indicators of severity. In the future, the quantitative measures of disease may have greater utility by showing correlation with prognosis, disease severity and other physiological parameters. These imaging features may provide non-invasive alternative endpoints or surrogate markers to alleviate the need for tissue biopsy or provide an accurate means to monitor rate of disease progression or response to therapy.

  9. Computed Tomography-Based Anatomic Assessment Overestimates Local Tumor Recurrence in Patients With Mass-like Consolidation After Stereotactic Body Radiotherapy for Early-Stage Non-Small Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunlap, Neal E.; Yang Wensha; McIntosh, Alyson

    Purpose: To investigate pulmonary radiologic changes after lung stereotactic body radiotherapy (SBRT), to distinguish between mass-like fibrosis and tumor recurrence. Methods and Materials: Eighty consecutive patients treated with 3- to 5-fraction SBRT for early-stage peripheral non-small cell lung cancer with a minimum follow-up of 12 months were reviewed. The mean biologic equivalent dose received was 150 Gy (range, 78-180 Gy). Patients were followed with serial CT imaging every 3 months. The CT appearance of consolidation was defined as diffuse or mass-like. Progressive disease on CT was defined according to Response Evaluation Criteria in Solid Tumors 1.1. Positron emission tomography (PET)more » CT was used as an adjunct test. Tumor recurrence was defined as a standardized uptake value equal to or greater than the pretreatment value. Biopsy was used to further assess consolidation in select patients. Results: Median follow-up was 24 months (range, 12.0-36.0 months). Abnormal mass-like consolidation was identified in 44 patients (55%), whereas diffuse consolidation was identified in 12 patients (15%), at a median time from end of treatment of 10.3 months and 11.5 months, respectively. Tumor recurrence was found in 35 of 44 patients with mass-like consolidation using CT alone. Combined with PET, 10 of the 44 patients had tumor recurrence. Tumor size (hazard ratio 1.12, P=.05) and time to consolidation (hazard ratio 0.622, P=.03) were predictors for tumor recurrence. Three consecutive increases in volume and increasing volume at 12 months after treatment in mass-like consolidation were highly specific for tumor recurrence (100% and 80%, respectively). Patients with diffuse consolidation were more likely to develop grade {>=}2 pneumonitis (odds ratio 26.5, P=.02) than those with mass-like consolidation (odds ratio 0.42, P=.07). Conclusion: Incorporating the kinetics of mass-like consolidation and PET to the current criteria for evaluating posttreatment response will increase the likelihood of correctly identifying patients with progressive disease after lung SBRT.« less

  10. Highly-sensitive and large-dynamic diffuse optical tomography system for breast tumor detection

    NASA Astrophysics Data System (ADS)

    Du, Wenwen; Zhang, Limin; Yin, Guoyan; Zhang, Yanqi; Zhao, Huijuan; Gao, Feng

    2018-02-01

    Diffuse optical tomography (DOT) as a new functional imaging has important clinical applications in many aspects such as benign and malignant breast tumor detection, tumor staging and so on. For quantitative detection of breast tumor, a three-wavelength continuous-wave DOT prototype system combined the ultra-high sensitivity of the photon-counting detection and the measurement parallelism of the lock-in technique was developed to provide high temporal resolution, high sensitivity, large dynamic detection range and signal-to-noise ratio. Additionally, a CT-analogous scanning mode was proposed to cost-effectively increase the detection data. To evaluate the feasibility of the system, a series of assessments were conducted. The results demonstrate that the system can obtain high linearity, stability and negligible inter-wavelength crosstalk. The preliminary phantom experiments show the absorption coefficient is able to be successfully reconstructed, indicating that the system is one of the ideal platforms for optical breast tumor detection.

  11. Diagnostic performance of 18F-FDG PET/CT and whole-body diffusion-weighted imaging with background body suppression (DWIBS) in detection of lymph node and bone metastases from pediatric neuroblastoma.

    PubMed

    Ishiguchi, Hiroaki; Ito, Shinji; Kato, Katsuhiko; Sakurai, Yusuke; Kawai, Hisashi; Fujita, Naotoshi; Abe, Shinji; Narita, Atsushi; Nishio, Nobuhiro; Muramatsu, Hideki; Takahashi, Yoshiyuki; Naganawa, Shinji

    2018-06-01

    Recent many studies have shown that whole body "diffusion-weighted imaging with background body signal suppression" (DWIBS) seems a beneficial tool having higher tumor detection sensitivity without ionizing radiation exposure for pediatric tumors. In this study, we evaluated the diagnostic performance of whole body DWIBS and 18 F-FDG PET/CT for detecting lymph node and bone metastases in pediatric patients with neuroblastoma. Subjects in this retrospective study comprised 13 consecutive pediatric patients with neuroblastoma (7 males, 6 females; mean age, 2.9 ± 2.0 years old) who underwent both 18 F-FDG PET/CT and whole-body DWIBS. All patients were diagnosed as neuroblastoma on the basis of pathological findings. Eight regions of lymph nodes and 17 segments of skeletons in all patients were evaluated. The images of 123 I-MIBG scintigraphy/SPECT-CT, bone scintigraphy/SPECT, and CT were used to confirm the presence of lymph node and bone metastases. Two radiologists trained in nuclear medicine evaluated independently the uptake of lesions in 18 F-FDG PET/CT and the signal-intensity of lesions in whole-body DWIBS visually. Interobserver difference was overcome through discussion to reach a consensus. The sensitivities, specificities, and overall accuracies of 18 F-FDG PET/CT and whole-body DWIBS were compared using McNemer's test. Positive predictive values (PPVs) and negative predictive values (NPVs) of both modalities were compared using Fisher's exact test. The total numbers of lymph node regions and bone segments which were confirmed to have metastasis in the total 13 patients were 19 and 75, respectively. The sensitivity, specificity, overall accuracy, PPV, and NPV of 18 F-FDG PET/CT for detecting lymph node metastasis from pediatric neuroblastoma were 100, 98.7, 98.9, 95.0, and 100%, respectively, and those for detecting bone metastasis were 90.7, 73.1, 80.3, 70.1, and 91.9%, respectively. In contrast, the sensitivity, specificity, overall accuracy, PPV, and NPV of whole-body DWIBS for detecting bone metastasis from pediatric neuroblastoma were 94.7, 24.0, 53.0, 46.4 and 86.7%, respectively, whereas those for detecting lymph node metastasis were 94.7, 85.3, 87.2, 62.1, and 98.5%, respectively. The low specificity, overall accuracy, and PPV of whole-body DWIBS for detecting bone metastasis were due to a high incidence of false-positive findings (82/108, 75.9%). The specificity, overall accuracy, and PPV of whole-body DWIBS for detecting lymph node metastasis were also significantly lower than those of 18 F-FDG PET/CT for detecting lymph node metastasis, although the difference between these 2 modalities was less than that for detecting bone metastasis. The specificity, overall accuracy, and PPV of whole-body DWIBS are significantly lower than those of 18 F-FDG PET/CT because of a high incidence of false-positive findings particularly for detecting bone metastasis, whereas whole-body DWIBS shows a similar level of sensitivities for detecting lymph node and bone metastases to those of 18 F-FDG PET/CT. DWIBS should be carefully used for cancer staging in children because of its high incidence of false-positive findings in skeletons.

  12. Numerical and experimental investigation of DNAPL removal mechanisms in a layered porous medium by means of soil vapor extraction.

    PubMed

    Yoon, Hongkyu; Oostrom, Mart; Wietsma, Thomas W; Werth, Charles J; Valocchi, Albert J

    2009-10-13

    The purpose of this work is to identify the mechanisms that govern the removal of carbon tetrachloride (CT) during soil vapor extraction (SVE) by comparing numerical and analytical model simulations with a detailed data set from a well-defined intermediate-scale flow cell experiment. The flow cell was packed with a fine-grained sand layer embedded in a coarse-grained sand matrix. A total of 499 mL CT was injected at the top of the flow cell and allowed to redistribute in the variably saturated system. A dual-energy gamma radiation system was used to determine the initial NAPL saturation profile in the fine-grained sand layer. Gas concentrations at the outlet of the flow cell and 15 sampling ports inside the flow cell were measured during subsequent CT removal using SVE. Results show that CT mass was removed quickly in coarse-grained sand, followed by a slow removal from the fine-grained sand layer. Consequently, effluent gas concentrations decreased quickly at first, and then started to decrease gradually, resulting in long-term tailing. The long-term tailing was mainly due to diffusion from the fine-grained sand layer to the coarse-grained sand zone. An analytical solution for a one-dimensional advection and a first-order mass transfer model matched the tailing well with two fitting parameters. Given detailed knowledge of the permeability field and initial CT distribution, we were also able to predict the effluent concentration tailing and gas concentration profiles at sampling ports using a numerical simulator assuming equilibrium CT evaporation. The numerical model predictions were accurate within the uncertainty of independently measured or literature derived parameters. This study demonstrates that proper numerical modeling of CT removal through SVE can be achieved using equilibrium evaporation of NAPL if detailed fine-scale knowledge of the CT distribution and physical heterogeneity is incorporated into the model. However, CT removal could also be fit by a first-order mass transfer analytical model, potentially leading to an erroneous conclusion that the long-term tailing in the experiment was kinetically controlled due to rate-limited NAPL evaporation.

  13. Parametric PET/MR Fusion Imaging to Differentiate Aggressive from Indolent Primary Prostate Cancer with Application for Image-Guided Prostate Cancer Biopsies

    DTIC Science & Technology

    2014-10-01

    Unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT The study investigates whether fusion PET/MRI imaging with 18F- choline PET/CT and...imaging with 18F- choline PET/CT and diffusion-weighted MRI can be successfully applied to target prostate cancer using image-guided prostate...Completed task. The 18F- choline synthesis was implemented and optimized for routine radiotracer production. RDRC committee approval as part of the IRB

  14. Optimization of Soft Tissue Management, Spacer Design, and Grafting Strategies For Large Segmental Bone Defects Using The Chronic Caprine Tibial Defect Model

    DTIC Science & Technology

    2014-10-01

    spacer placed at the time of the “Pre-Procedure”. Autogenous Cancellous Bone Graft (ACBG harvested from the sternum at the time of the treatment...will receive more specialized training and orientation to microCT analysis, both on a theoretical and practical level. He will work with raw CT...adjacent to the PMMA) composed of mononuclear cells and exhibited extensive, diffuse fibrous connective tissue.  Performed histology on goat autogenous

  15. Acute encephalopathy with biphasic seizures and late reduced diffusion associated with hemophagocytic syndrome.

    PubMed

    Tadokoro, Rieko; Okumura, Akihisa; Nakazawa, Tomoyuki; Hara, Satoshi; Yamakawa, Yoko; Kamata, Ayako; Kinoshita, Keiji; Obinata, Kaoru; Shimizu, Toshiaki

    2010-06-01

    We reported a girl with HHV-6 infection associated with both acute encephalopathy with biphasic seizures and late reduced diffusion, and hemophagocytic syndrome. She had a prolonged convulsion after a one-day history of febrile illness. Cerebrospinal fluid or brain CT showed no abnormalities on admission and her consciousness was recovered on the next day. However, a prolonged seizure and deterioration of consciousness appeared on the sixth day of illness. Diffusion-weighted images revealed marked reduction of water diffusion in the bilateral frontal areas. HHV-6 infection was virologically proven by polymerase chain reaction. She was treated with gamma-globulin, steroid pulse therapy, and brain hypothermia. In addition, decrease in white blood cells and platelet counts, and elevation of liver enzymes and ferritin were noted on the fourth day of illness. Hemophagocytic macrophages were revealed by bone marrow aspiration on the sixth day. Her hematological and blood chemistry abnormalities recovered gradually after steroid pulse therapy. An elevation of interleukin-6, -8, and -10, and tumor necrosis factor in the serum and that of interleukin-4, -6, and-8 in the cerebrospinal fluid were observed at the onset of a late seizure. These facts suggested that hypercytokinemia will be related to the pathogenesis of acute encephalopathy of our patient. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  16. [Diagnosis and treatment of diffuse tenosynovial giant cell tumor arising from temporomandibular joints].

    PubMed

    Meng, J H; Guo, Y X; Luo, H Y; Guo, C B; Ma, X C

    2016-12-18

    To retrospectively analyze the clinical features, treatment and prognosis to the diffuse tenosynovial giant cell tumor (D-TSGCT) arising from the temporomandibular joint (TMJ), and to give a reference for the early diagnosis and treatment of this disease. In this study, 15 patients finally diagnosed as D-TSGCT of TMJ histopathologically at the Peking University Hospital of Stomatology from October 2003 to August 2015 were selected and reviewed. Their clinical manifestations, imaging and histological features, diagnoses and differential diagnoses, treatments and follow-ups were summarized and discussed. D-TSGCT of TMJ showed obvious female predominance (12/15), the main symptoms included painful preauricular swelling or mass, limited mouth-opening and mandibular deviation with movement. D-TSGCT on computed tomography (CT) scan often showed ill-defined soft tissue masses around TMJ, enhancement after contrast administration, usually with widening of the joint spaces and with bone destruction of the condyle, the fossa and even the skull base. On magnetic resonance images (MRI), the majority of lesions on T1 weighted images and T2 weighted images both showed the characteristics of low signals (6/11). The lesions could extend beyond the joints (9/11) and into the infratemporal fossa (4/11) and the middle cranial fossa (4/11). Surgical resection was performed in 14 cases and biopsy in 1 case. Postoperative radiotherapy was performed in 3 cases. In follow-ups, 3 cases showed recurrence postoperatively. D-TSGCT arising from TMJ should be differentiated with TMJ disorders, other tumors and tumor-like lesions of TMJ and parotid neoplasms, etc. CT and MRI examinations have important values in the diagnosis and treatment design of D-TSGCT. Because of the local aggressive and extensive behavior, complete resection should be performed as soon as possible. Postoperative radiotherapy was helpful for the extensive lesions including destruction of skull base and may be a good supplementary therapy. Because of the possibility of recurrence and malignancy, long-term follow-up was suggested.

  17. Further characterization of spectral features attributable to titanium on the moon

    NASA Technical Reports Server (NTRS)

    Burns, R. G.; Parkin, K. M.; Loeffler, B. M.; Leung, I. S.; Abu-Eid, R. M.

    1976-01-01

    The following transitions are observed in the electronic absorption spectra of lunar titanaugites: Fe(2+) spin-allowed and spin-forbidden crystal field; Ti(3+) spin allowed and Jahn-Teller split crystal field; Ti(3+)-Ti(4+) CT; Fe(2+)-Ti(4+) CT; and O(2-)-Fe(2+), Ti(3+), Ti(4+) CT. Of these, the transitions involving Ti(3+) are unique to lunar or nonferric-bearing titanaugites. All titanaugites have the Fe(2+) crystal field and Fe(2+)-Ti(4+) CT transitions in common. These features in the diffuse reflectance spectra of lunar materials give rise to the '1.0 band' and to the observed absorption around 0.5-0.6 micron, respectively. Since regolith contains a variety of phases with coexisting Fe(2+), Ti(3+), and Ti(4+) ions, several metal-metal charge transfer processes are possible.

  18. Malignant pleural disease: diagnosis by using diffusion-weighted and dynamic contrast-enhanced MR imaging--initial experience.

    PubMed

    Coolen, Johan; De Keyzer, Frederik; Nafteux, Philippe; De Wever, Walter; Dooms, Christophe; Vansteenkiste, Johan; Roebben, Ilse; Verbeken, Eric; De Leyn, Paul; Van Raemdonck, Dirk; Nackaerts, Kristiaan; Dymarkowski, Steven; Verschakelen, Johny

    2012-06-01

    To investigate the use of diffusion-weighted (DW) imaging for differentiating benign lesions from malignant pleural disease (MPD) and to retrospectively assess dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging acquisitions to find out whether combining these measurements with DW imaging could improve the diagnostic value of DW imaging. This study was approved by the local ethics committee, and all patients provided written informed consent. Thirty-one consecutive patients with pleural abnormalities suspicious for MPD underwent whole-body positron emission tomography (PET)/computed tomography (CT) and thorax MR examinations. Diagnostic thoracoscopy with histopathologic analysis of pleural biopsies served as the reference standard. First-line evaluation of each suspicious lesion was performed by using the apparent diffusion coefficient (ADC) calculated from the DW image, and the optimal cutoff value was found by using receiver operating characteristic curve analysis. Afterward, DCE MR imaging data were used to improve the diagnosis in the range of ADCs where DW imaging results were equivocal. Sensitivity, specificity, and accuracy of PET/CT for diagnosis of MPD were 100%, 35.3%, and 64.5%. The optimal ADC threshold to differentiate benign lesions from MPD with DW MR imaging was 1.52 × 10(-3) mm(2)/sec, with sensitivity, specificity, and accuracy of 71.4%, 100%, and 87.1%, respectively. This result could be improved to 92.8%, 94.1%, and 93.5%, respectively, when DCE MR imaging data were included in those cases where ADC was between 1.52 and 2.00 × 10(-3) mm(2)/sec. A total of 20 patients had disease diagnosed correctly, nine had disease diagnosed incorrectly, and two cases were undetermined with PET/CT. DW imaging helped stage disease correctly in 27 patients and incorrectly in four. The undetermined cases at PET/CT were correctly diagnosed at MR imaging. DW imaging is a promising tool for differentiating MPD from benign lesions, with high accuracy, and supplementation with DCE MR imaging seems to further improve sensitivity.

  19. Cavernous sinus syndrome due to osteochondromatosis in a cat.

    PubMed

    Perazzi, Anna; Bernardini, Marco; Mandara, Maria T; De Benedictis, Giulia M; De Strobel, Francesca; Zotti, Alessandro

    2013-12-01

    A 1-year-old sexually intact male Korat cat was referred for ophthalmological consultation due to anisocoria. Mydriasis with external ophthalmoplegia and absence of pupillary light responses in the right eye and nasofacial hypalgesia were seen. Cavernous sinus syndrome (CSS) was suspected. Bilateral deformities of the jaw and phalangeal bones, severe spinal pain and abnormal conformation of the lumbar spine were also present. Radiographic examination revealed several mineralised masses in the appendicular and axial skeleton, indicative of multiple cartilaginous exostoses. For further investigation of the CSS-related neurological deficits, the cat underwent computed tomography (CT) examination of the skull. CT images revealed a non-vascularised, calcified, amorphous mass originating from the right lateral skull base and superimposing on the sella turcica. Based on the severity of diffuse lesions and owing to the clinical signs of extreme pain, the cat was euthanased. A diffuse skeletal and intracranial osteochondromatosis was diagnosed histologically.

  20. [A case of Kartagener's syndrome].

    PubMed

    Ishiga, Takeshi; Tanigawa, Motoaki; Ichioka, Maresuke; Saito, Kimimasa

    2005-03-01

    This case describes a 57-year-old woman in whom situs inversus had been noted at her birth. She had bronchial asthma and bilateral sinusitis during her childhood. She married and experienced childbirth. In December 2003, she was admitted to our Division complaining of wheezing, expectoration and dyspnea on effort. Bronciectasis was visualized on chest X-ray and CT. Electron microscopic examination of the nasal cavity epithelium and bronchial epithelial cilia revealed a deficit of bilateral dynein arms. These findings, helped establish a diagnosis of Kartagener's syndrome, which is characterized by primary ciliary dyskinesia. The restrictive and obstructive pulmonary dysfunction with increase of residual volume in the lung function tests and diffuse centrilobular small nodules with hyperinflation on chest CT were consistent with the findings of diffuse panbronchilitis (DPB) and suggested extended obliterative peripheral airway disease. Clarithromycin which is highly effective for DPB failed to prevent the aggravation of airway infection, arousing the concern about the progression into chronic respiratory failure.

  1. Bidirectional reflectance distribution function effects in ladar-based reflection tomography.

    PubMed

    Jin, Xuemin; Levine, Robert Y

    2009-07-20

    Light reflection from a surface is described by the bidirectional reflectance distribution function (BRDF). In this paper, BRDF effects in reflection tomography are studied using modeled range-resolved reflection from well-characterized geometrical surfaces. It is demonstrated that BRDF effects can cause a darkening at the interior boundary of the reconstructed surface analogous to the well-known beam hardening artifact in x-ray transmission computed tomography (CT). This artifact arises from reduced reflection at glancing incidence angles to the surface. It is shown that a purely Lambertian surface without shadowed components is perfectly reconstructed from range-resolved measurements. This result is relevant to newly fabricated carbon nanotube materials. Shadowing is shown to cause crossed streak artifacts similar to limited-angle effects in CT reconstruction. In tomographic reconstruction, these effects can overwhelm highly diffuse components in proximity to specularly reflecting elements. Diffuse components can be recovered by specialized processing, such as reducing glints via thresholded measurements.

  2. Primary sternum diffuse large B-cell lymphoma: A case report and review of the literature

    PubMed Central

    TONG, MENG-YING; ZHANG, XIAN; YU, ZHE; SUN, XIU-HUA; LI, SHUANG; ZHANG, YANG

    2015-01-01

    Primary bone lymphoma (PBL) is a rare disease, accounting for >1% of all cases of malignant lymphoma. Diffuse large B-cell lymphoma (DLBCL) is the most common histological type of PBL. The present study reported the case of a 68-year-old male with primary bone DLBCL, originally occurred in the sternum, which is a rare form of presentation. Computed tomography (CT), magnetic resonance imaging and bone emission CT were performed, followed by immunohistochemical analysis of a biopsy specimen, and the results were used to establish the diagnosis. At the time of diagnosis, no osseous involvement was observed. The clinical, radiological and histological features of PBL can mimic other medical conditions, thereby making the diagnosis difficult, and frequently leading to delays in treatment. The present study investigated the clinical features, management and prognosis of PBL, and reviewed previous relevant cases. PMID:26137117

  3. [Radiological diagnostics in CUP syndrome].

    PubMed

    Kazmierczak, P M; Nikolaou, K; Rominger, A; Graser, A; Reiser, M F; Cyran, C C

    2014-02-01

    Imaging plays an essential role in the therapeutic management of cancer of unknown primary (CUP) patients for localizing the primary tumor, for the identification of tumor entities for which a dedicated therapy regimen is available and for the characterization of clinicopathological subentities that direct the subsequent diagnostic and therapeutic strategy. Modalities include conventional x-ray, computed tomography (CT), magnetic resonance imaging (MRI) and ultrasound as well as positron emission tomography (PET)-CT and MRI-PET. In whole body imaging CT has a high sensitivity for tumor entities which frequently present as a metastasized cancer illness. According to the current literature CT is diagnostic in 86% of patients with pancreatic carcinoma, in 36% of patients with colon carcinoma and in 74% of patients with lung carcinoma. Additionally a meta-analysis showed that for patients with squamous cell carcinoma and cervical lymph node metastases a positive diagnosis was possible in 22% of the cases using CT, in 36% using MRI and in 28-57% using 18F-fluorodeoxyglucose PET-CT ((18)F-FDG PET-CT). In addition, MRI plays an important role in the localization of primary occult tumors (e.g. breast and prostate) because of its high soft tissue contrast and options for functional imaging. At the beginning of the diagnostic algorithm stands the search for a possible primary tumor and CT of the neck, thorax and abdomen is most frequently used for whole body staging. Subsequent organ-specific imaging examinations follow, e.g. mammography in women with axillary lymphadenopathy. For histological and immunohistochemical characterization of tumor tissue, imaging is also applied to identify the most accessible and representative tumor manifestation for biopsy. Tumor biopsy may be guided by CT, MRI or ultrasound and MRI also plays a central role in the localization of primary occult tumors because of superior soft tissue contrast and options for functional imaging (perfusion, diffusion), e.g. investigation of breast carcinoma or prostate carcinoma. Whole body staging stands at the beginning of the diagnostic algorithm in CUP syndrome to localize a potential primary tumor. Clinically, contrast-enhanced CT of the neck, thorax and abdomen is frequently applied; however, many studies have demonstrated augmented sensitivity of (18)F-FDG PET-CT for the detection of primary tumors and metastatic tumor manifestations.

  4. Histogram Analysis of Apparent Diffusion Coefficients for Occult Tonsil Cancer in Patients with Cervical Nodal Metastasis from an Unknown Primary Site at Presentation.

    PubMed

    Choi, Young Jun; Lee, Jeong Hyun; Kim, Hye Ok; Kim, Dae Yoon; Yoon, Ra Gyoung; Cho, So Hyun; Koh, Myeong Ju; Kim, Namkug; Kim, Sang Yoon; Baek, Jung Hwan

    2016-01-01

    To explore the added value of histogram analysis of apparent diffusion coefficient (ADC) values over magnetic resonance (MR) imaging and fluorine 18 ((18)F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) for the detection of occult palatine tonsil squamous cell carcinoma (SCC) in patients with cervical nodal metastasis from a cancer of an unknown primary site. The institutional review board approved this retrospective study, and the requirement for informed consent was waived. Differences in the bimodal histogram parameters of the ADC values were assessed among occult palatine tonsil SCC (n = 19), overt palatine tonsil SCC (n = 20), and normal palatine tonsils (n = 20). One-way analysis of variance was used to analyze differences among the three groups. Receiver operating characteristic curve analysis was used to determine the best differentiating parameters. The increased sensitivity of histogram analysis over MR imaging and (18)F-FDG PET/CT for the detection of occult palatine tonsil SCC was evaluated as added value. Histogram analysis showed statistically significant differences in the mean, standard deviation, and 50th and 90th percentile ADC values among the three groups (P < .0045). Occult palatine tonsil SCC had a significantly higher standard deviation for the overall curves, mean and standard deviation of the higher curves, and 90th percentile ADC value, compared with normal palatine tonsils (P < .0167). Receiver operating characteristic curve analysis showed that the standard deviation of the overall curve best delineated occult palatine tonsil SCC from normal palatine tonsils, with a sensitivity of 78.9% (15 of 19 patients) and a specificity of 60% (12 of 20 patients). The added value of ADC histogram analysis was 52.6% over MR imaging alone and 15.8% over combined conventional MR imaging and (18)F-FDG PET/CT. Adding ADC histogram analysis to conventional MR imaging can improve the detection sensitivity for occult palatine tonsil SCC in patients with a cervical nodal metastasis originating from a cancer of an unknown primary site. © RSNA, 2015.

  5. Correlation between standardized uptake value and apparent diffusion coefficient of neoplastic lesions evaluated with whole-body simultaneous hybrid PET/MRI.

    PubMed

    Rakheja, Rajan; Chandarana, Hersh; DeMello, Linda; Jackson, Kimberly; Geppert, Christian; Faul, David; Glielmi, Christopher; Friedman, Kent P

    2013-11-01

    The purpose of this study was to assess the correlation between standardized uptake value (SUV) and apparent diffusion coefficient (ADC) of neoplastic lesions in the use of a simultaneous PET/MRI hybrid system. Twenty-four patients with known primary malignancies underwent FDG PET/CT. They then underwent whole-body PET/MRI. Diffusion-weighted imaging was performed with free breathing and a single-shot spin-echo echo-planar imaging sequence with b values of 0, 350, and 750 s/mm(2). Regions of interest were manually drawn along the contours of neoplastic lesions larger than 1 cm, which were clearly identified on PET and diffusion-weighted images. Maximum SUV (SUVmax) on PET/MRI and PET/CT images, mean SUV (SUVmean), minimum ADC (ADCmin), and mean ADC (ADCmean) were recorded on PET/MR images for each FDG-avid neoplastic soft-tissue lesion with a maximum of three lesions per patient. Pearson correlation coefficient was used to asses the following relations: SUVmax versus ADCmin on PET/MR and PET/CT images, SUVmean versus ADCmean, and ratio of SUVmax to mean liver SUV (SUV ratio) versus ADCmin. A subanalysis of patients with progressive disease versus partial treatment response was performed with the ratio of SUVmax to ADCmin for the most metabolically active lesion. Sixty-nine neoplastic lesions (52 nonosseous lesions, 17 bone metastatic lesions) were evaluated. The mean SUVmax from PET/MRI was 7.0 ± 6.0; SUVmean, 5.6 ± 4.6; mean ADCmin, 1.10 ± 0.58; and mean ADCmean, 1.48 ± 0.72. A significant inverse Pearson correlation coefficient was found between PET/MRI SUVmax and ADCmin (r = -0.21, p = 0.04), between SUVmean and ADCmean (r = -0.18, p = 0.07), and between SUV ratio and ADCmin (r = -0.27, p = 0.01). A similar inverse Pearson correlation coefficient was found between the PET/CT SUVmax and ADCmin. Twenty of 24 patients had previously undergone PET/CT; five patients had a partial treatment response, and six had progressive disease according to Response Evaluation Criteria in Solid Tumors 1.1. The ratio between SUVmax and ADCmin was higher among patients with progressive disease than those with a partial treatment response. Simultaneous PET/MRI is a promising technology for the detection of neoplastic disease. There are inverse correlations between SUVmax and ADCmin and between SUV ratio and ADCmin. Correlation coefficients between SUVmax and ADCmin from PET/MRI were similar to values obtained with SUVmax from the same-day PET/CT. Given that both SUV and ADC are related to malignancy and that the correlation between the two biomarkers is relatively weak, SUV and ADC values may offer complementary information to aid in determination of prognosis and treatment response. The combined tumoral biomarker, ratio between SUVmax and ADCmin, may be useful for assessing progressive disease versus partial treatment response.

  6. [Features of Acquired Immunodeficiency Syndrome-related Lymphoma on (18)F-fluorodeoxyglucose Positron Emission Tomography/Computed Tomography].

    PubMed

    Niu, Na; Zhu, Zhao-hui; Ma, Yan-ru; Xing, Hai-qun; Li, Fang

    2015-10-01

    To analyze the imaging features of (18)F-fluorodeoxyglucose (¹⁸F-FDG) positron emission tomography(PET)/computed tomography (CT) in acquired immune deficiency syndrome-related lymphoma (ARL) patients correlated with their clinical signs, symptoms, and treatments. Five ARL patients underwent ¹⁸F-FDG PET/CT at Peking Union Medical College Hospital from October 2008 to January 2013. Two patients received two additional follow-up studies 6 months later. Among these 5 patients, ¹⁸FDG-PET/CT helped in diagnosis of two patient and changed therapeutic strategy in other two patients. In two patients underwent ¹⁸F-FDG PET/CT brain scans, low-metabolism lesion was newly found in cerebral cortex. Of 4 patients receiving highly active antiretroviral therapy, PET/CT also demonstrated diffusely elevated ¹⁸F-FDG uptake in subcutaneous adipose tissue in two patients. ¹⁸F-FDG PET/CT is a highly useful tool in the diagnosis and treatment of ARL patients, in particular in the identification of associated encephalopathy and lipodystrophy.

  7. Hybrid [¹⁸F]-FDG PET/MRI including non-Gaussian diffusion-weighted imaging (DWI): preliminary results in non-small cell lung cancer (NSCLC).

    PubMed

    Heusch, Philipp; Köhler, Jens; Wittsack, Hans-Joerg; Heusner, Till A; Buchbender, Christian; Poeppel, Thorsten D; Nensa, Felix; Wetter, Axel; Gauler, Thomas; Hartung, Verena; Lanzman, Rotem S

    2013-11-01

    To assess the feasibility of non-Gaussian DWI as part of a FDG-PET/MRI protocol in patients with histologically proven non-small cell lung cancer. 15 consecutive patients with histologically proven NSCLC (mean age 61 ± 11 years) were included in this study and underwent whole-body FDG-PET/MRI following whole-body FDG-PET/CT. As part of the whole-body FDG-PET/MRI protocol, an EPI-sequence with 5 b-values (0, 100, 500, 1000 and 2000 s/mm(2)) was acquired for DWI of the thorax during free-breathing. Volume of interest (VOI) measurements were performed to determine the maximum and mean standardized uptake value (SUV(max); SUV(mean)). A region of interest (ROI) was manually drawn around the tumor on b=0 images and then transferred to the corresponding parameter maps to assess ADC(mono), D(app) and K(app). To assess the goodness of the mathematical fit R(2) was calculated for monoexponential and non-Gaussian analysis. Spearman's correlation coefficients were calculated to compare SUV values and diffusion coefficients. A Student's t-test was performed to compare the monoexponential and non-Gaussian diffusion fitting (R(2)). T staging was equal between FDG-PET/CT and FDG-PET/MRI in 12 of 15 patients. For NSCLC, mean ADC(mono) was 2.11 ± 1.24 × 10(-3) mm(2)/s, Dapp was 2.46 ± 1.29 × 10(-3) mm(2)/s and mean Kapp was 0.70 ± 0.21. The non-Gaussian diffusion analysis (R(2)=0.98) provided a significantly better mathematical fitting to the DWI signal decay than the monoexponetial analysis (R(2)=0.96) (p<0.001). SUV(max) and SUV(mean) of NSCLC was 13.5 ± 7.6 and 7.9 ± 4.3 for FDG-PET/MRI. ADC(mono) as well as Dapp exhibited a significant inverse correlation with the SUV(max) (ADC(mono): R=-0.67; p<0.01; Dapp: R=-0.69; p<0.01) as well as with SUV(mean) assessed by FDG-PET/MRI (ADC(mono): R=-0.66; p<0.01; Dapp: R=-0.69; p<0.01). Furthermore, Kapp exhibited a significant correlation with SUV(max) (R=0.72; p<0.05) and SUV(mean) as assessed by FDG-PET/MRI (R=0.71; p<0.005). Simultaneous PET and non-Gaussian diffusion acquisitions are feasible. Non-Gaussian diffusion parameters show a good correlation with SUV and might provide additional information beyond monoexponential ADC, especially as non-Gaussian diffusion exhibits better mathematical fitting to the decay of the diffusion signal than monoexponential DWI. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. [PET/CT: protocol aspects and legal controversies].

    PubMed

    Gorospe Sarasúa, L; Vicente Bártulos, A; González Gordaliza, C; García Poza, J; Lourido García, D; Jover Díaz, R

    2008-01-01

    The combination of positron emission tomography (PET) and computed tomography (CT) in a single scanner (PET/CT) allows anatomic and metabolic images to be fused and correlated with a high degree of accuracy; this represents a very important landmark in the history of medicine and especially in the area of diagnostic imaging. Nevertheless, the implementation, startup, and operation of a PET/CT scanner presents particularly interesting challenges, because it involves the integration of two well-established and consolidated techniques (CT and PET, which provide complementary information) that have traditionally been carried out in the context of two different specialties (radiology and nuclear medicine). The rapid diffusion of this new integrated technology raises a series of questions related to the optimal protocols for image acquisition, the supervision of the examinations, image interpretation, and reporting, as well as questions related to the legal competence and responsibility of the specialists involved in a PET/CT study. The objective of this article is to approach these aspects from a constructive perspective and to stimulate the dialog between the specialties of radiology and nuclear medicine, with the aim of maximizing the diagnostic potential of PET/CT and thus of providing better care for patients.

  9. Role of (18)F-FDG PET-CT in Monitoring the Cyclophosphamide Induced Pulmonary Toxicity in Patients with Breast Cancer - 2 Case Reports.

    PubMed

    Taywade, Sameer Kamalakar; Kumar, Rakesh; Bhethanabhotla, Sainath; Bal, Chandrasekhar

    2016-09-01

    Drug induced pulmonary toxicity is not uncommon with the use of various chemotherapeutic agents. Cyclophosphamide is a widely used chemotherapeutic drug in the treatment of breast cancer. Although rare, lung toxicity has been reported with cyclophosphamide use. Detection of bleomycin induced pulmonary toxicity and pattern of (18)F-fluorodeoxyglucose ((18)F-FDG) uptake in lungs on fluorodeoxyglucose positron emission tomography-computed tomography ((18)F-FDG PET-CT) has been elicited in literature in relation to lymphoma. However, limited data is available regarding the role of (18)F-FDG PET-CT in monitoring drug induced pulmonary toxicity in breast cancer. We here present two cases of cyclophosphamide induced drug toxicity. Interim (18)F-FDG PET-CT demonstrated diffusely increased tracer uptake in bilateral lung fields in both these patients. Subsequently there was resolution of lung uptake on (18)F-FDG PET-CT scan post completion of chemotherapy. These patients did not develop significant respiratory symptoms during chemotherapy treatment and in follow up.

  10. Differentiation of Central Lung Cancer from Atelectasis: Comparison of Diffusion-Weighted MRI with PET/CT

    PubMed Central

    Yang, Rui-Meng; Li, Long; Wei, Xin-Hua; Guo, Yong-Mei; Huang, Yun-Hai; Lai, Li-Sha; Chen, A-Mei; Liu, Guo-Shun; Xiong, Wei-Feng; Luo, Liang-Ping; Jiang, Xin-Qing

    2013-01-01

    Objective Prospectively assess the performance of diffusion-weighted magnetic resonance imaging (DW-MRI) for differentiation of central lung cancer from atelectasis. Materials and Methods 38 consecutive lung cancer patients (26 males, 12 females; age range: 28–71 years; mean age: 49 years) who were referred for thoracic MR imaging examinations were enrolled. MR examinations were performed using a 1.5-T clinical scanner and scanning sequences of T1WI, T2WI, and DWI. Cancers and atelectasis were measured by mapping of the apparent diffusion coefficients (ADCs) obtained with a b-value of 500 s/mm2. Results PET/CT and DW-MR allowed differentiation of tumor and atelectasis in all 38 cases, but T2WI did not allow differentiation in 9 cases. Comparison of conventional T2WI and DW-MRI indicated a higher contrast noise ratio of the central lung carcinoma than the atelectasis by DW-MRI. ADC maps indicated significantly lower mean ADC in the central lung carcinoma than in the atelectasis (1.83±0.58 vs. 2.90±0.26 mm2/s, p<0.0001). ADC values of small cell lung carcinoma were significantly greater than those from squamous cell carcinoma and adenocarcinoma (p<0.0001 for both). Conclusions DW-MR imaging provides valuable information not obtained by conventional MR and may be useful for differentiation of central lung carcinoma from atelectasis. Future developments may allow DW-MR imaging to be used as an alternative to PET-CT in imaging of patients with lung cancer. PMID:23593186

  11. Primary pulmonary lymphoma in a patient with advanced AIDS

    PubMed Central

    Shahani, Lokesh; McKenna, Megan

    2014-01-01

    Non-Hodgkin's lymphoma (NHL) is an AIDS defining lesion and risk of NHL most likely correlates with the degree of immunosuppression from HIV. Risk of NHL is highest among patients with CD4 count <50 cells/mL. Primary pulmonary lymphoma (PPL) is an infrequent cause of AIDS-related lymphoma. The authors report a patient with advanced AIDS presenting with recurrent fever and pulmonary nodule seen on the CT scan. The patient remained febrile despite being on broad spectrum antibiotics with no clear source of infection. The patient underwent a bronchoscopy with biopsy of the pulmonary lesion which was most consistent with diffuse large B-cell lymphoma. The patient was started on dose-adjusted etoposide, vincristine, doxorubicin, cyclophosphamide and prednisone (EPOCH) and was noted to be afebrile and a repeat CT scan few weeks later showed resolution of her pulmonary nodule. This case highlights the importance of considering NHL in patients with advanced AIDS presenting with pulmonary nodule and fever. PMID:25527680

  12. Irreversible Electroporation in a Swine Lung Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dupuy, Damian E., E-mail: ddupuy@lifespan.org; Aswad, Bassam, E-mail: baswad@lifespan.org; Ng, Thomas, E-mail: tng@usasurg.org

    2011-04-15

    Purpose: This study was designed to evaluate the safety and tissue effects of IRE in a swine lung model. Methods: This study was approved by the institutional animal care committee. Nine anesthetized domestic swine underwent 15 percutaneous irreversible electroporation (IRE) lesion creations (6 with bipolar and 3 with 3-4 monopolar electrodes) under fluoroscopic guidance and with pancuronium neuromuscular blockade and EKG gating. IRE electrodes were placed into the central and middle third of the right mid and lower lobes in all animals. Postprocedure PA and lateral chest radiographs were obtained to evaluate for pneumothorax. Three animals were sacrificed at 2more » weeks and six at 4 weeks. Animals underwent high-resolution CT scanning and PA and lateral radiographs 1 h before sacrifice. The treated lungs were removed en bloc, perfused with formalin, and sectioned. Gross pathologic and microscopic changes after standard hematoxylin and eosin staining were analyzed within the areas of IRE lesion creation. Results: No significant adverse events were identified. CT showed focal areas of spiculated high density ranging in greatest diameter from 1.1-2.2 cm. On gross inspection of the sectioned lung, focal areas of tan discoloration and increased density were palpated in the areas of IRE. Histological analysis revealed focal areas of diffuse alveolar damage with fibrosis and inflammatory infiltration that respected the boundaries of the interlobular septae. No pathological difference could be discerned between the 2- and 4-week time points. The bronchioles and blood vessels within the areas of IRE were intact and did not show signs of tissue injury. Conclusion: IRE creates focal areas of diffuse alveolar damage without creating damage to the bronchioles or blood vessels. Short-term safety in a swine model appears to be satisfactory.« less

  13. Acute gastrointestinal vaso-occlusive ischemia in sickle cell disease: CT imaging features and clinical outcome.

    PubMed

    Gardner, Carly S; Jaffe, Tracy A

    2016-03-01

    The purpose of this study was to determine the incidence, specific imaging features, and outcome of gastrointestinal vaso-occlusive ischemia (GVOI) in sickle cell patients undergoing CT for acute abdominal pain. This HIPAA-compliant, IRB-approved retrospective study evaluated sickle cell patients with an abdominal pain crisis and acute gastrointestinal abnormalities on CT from 1/2006 to 1/2014. CT findings were divided into those compatible and incompatible with bowel ischemia or clinical diagnosis of GVOI. Two abdominal radiologists (1, 13 years' experience) reviewed the CTs for specific imaging features of ischemia. Clinical laboratory values (lactate, WBC) and outcome were recorded. Descriptive statistics and Wilcoxon-Mann-Whitney two-sample rank-sum test were performed. Of 217 CTs, 33 had acute gastrointestinal abnormalities: 75% (25/33) consistent with ischemia and clinical GVOI. Complications of ischemia occurred in 16% (4/25): ileus (50%), perforation (25%), and pneumatosis (25%). In uncomplicated cases, all had bowel wall thickening: segmental 52% (11/21) or diffuse 48% (10/21). The colon was commonly involved (76%, 16/21), particularly the ascending (57%, 12/21). Most abnormalities (52%, 11/21) were in the superior mesenteric artery distribution. Average lactate (4.3 ± 4.0 mmol/L, p = 0.02) and WBC count (20.1 ± 10.4, ×1000 cells/μL, p = 0.01) were significantly higher in GVOI. Overall mortality in patients with GVOI was 17% (3/18). GVOI is an important feature of the acute abdominal crisis in patients with sickle cell disease and can be seen in up to 75% of patients with abnormal bowel findings on CT. The diagnosis should be strongly considered in sickle cell patients with CT findings of diffuse or segmental bowel wall thickening, particularly involving the colon.

  14. [The clinical characteristics of pulmonary benign metastasizing leiomyoma].

    PubMed

    Wang, H P; Shi, J H; Zhang, L

    2017-07-01

    Objective: Pulmonary benign metastasizing leiomyoma (PBML) is a rare entity that leiomyoma of uterus metastasized to the lung. The clinical characteristics of this rare disease were analyzed in this article. Methods: The detailed clinical records of 7 patients diagnosed as PBML at Peking Union Medical College Hospital between January 2001 and June 2015 were reviewed. Results: All patients were women with median age of 44 years (range 28-62). Symptoms included dyspnea (2/7), chest pain (1/7), cyanosis (1/7), cough (1/7) and bloody sputum (1/7), while 4/7 cases were asymptomatic. Six patients had the past-history of leiomyoma of uterus 20 months to 14 years ago among whom 5 patients received hysterectomy. Chest CT showed bilateral, random-distributed multiple round solid nodules, or diffuse-distributed miliary nodules, or single solid nodule, even some small cavities. Extra-pulmonary metastasis was found in left superclavicular lymph node (1 case) and right heart (1 case). Histological tissues were obtained by video-assisted thoracic surgery lung biopsy (4/7), mass resection on tricuspid valve (1/7), transbronchil lung biopsy (1/7), and CT-guided percutaneous lung biopsy (1/7). Pathology showed an interlacing pattern by spindle cells having elongated nuclei without cellular atypia. Ki-67 index was less than 1%. Molecules such as smooth muscle antibody, estrogen receptor (ER) and progestrone receptor (PR) were positive in immunohistochemistry staining. Neither letrozole nor zoladex was effective. Two patients responded to bilateral adnexectomy, presenting as shrunk nodules. No relapsed disease was seen in one patient with single nodule after resection. There was only one patient with disease-related mortality, whose chest CT showed milliary nodules. Conclusion: Although CT findings of PBML are similar to malignancies, the clinical outcome is good. Despite the positive expression of ER and PR, the effectiveness of hormone related treatment is limited. And periodical follow up is suggested even to those uneventful patients.

  15. Metastatic Renal Cell Carcinoma Masquerading as Jugular Foramen Paraganglioma: A Role for Novel Magnetic Resonance Imaging.

    PubMed

    Thomas, Andrew J; Wiggins, Richard H; Gurgel, Richard K

    2017-08-01

    To describe a case of metastatic renal cell carcinoma (RCC) masquerading as a jugular foramen paraganglioma (JP). To compare imaging findings between skull base metastatic RCC and histologically proven paraganglioma. A case of unexpected metastatic skull base RCC is reviewed. Computed tomography (CT) and magnetic resonance imaging (MRI) were compared between 3 confirmed cases of JP and our case of metastatic RCC. Diffusion-weighted MRI (DW-MRI) sequences and computed apparent diffusion coefficient (ADC) values were compared between these entities. A 55-year-old man presents with what appears clinically and radiographically to be JP. The tumor was resected, then discovered on postoperative pathology to be metastatic RCC. Imaging was retrospectively compared between 3 histologically confirmed cases of JP and our case of skull base RCC. The RCC metastasis was indistinguishable from JP on CT and traditional MRI but distinct by ADC values calculated from DW-MRI. Metastatic RCC at the skull base may mimic the clinical presentation and radiographic appearance of JP. The MRI finding of flow voids is seen in both paraganglioma and metastatic RCC. Diffusion-weighted MRI is able to distinguish these entities, highlighting its potential utility in distinguishing skull base lesions.

  16. Spatial distribution of dialysate in patients and its implications to intradialysate diffusion.

    PubMed

    Hills, Brian A; Birch, Seamus; Burke, John R; LaMont, Anthony C

    2002-01-01

    To visualize and quantify the spatial distribution of dialysate in patients on continuous ambulatory peritoneal dialysis (CAPD) and, hence, estimate diffusion times for fluid "pockets" wherever intradialysate concentration gradients may not be dissipated by convective currents. Contrast medium was added to the dialysate of three supine CAPD patients before an exchange prior to computed tomographic (CT) scanning. Spatial information in the CT scanner was then downloaded to other computers and processed to produce impressive three-dimensional models of dialysate distribution using "wire frame technology." Models differed between patients but all demonstrated pooling of dialysate in the paracolic gutters, subphrenic space, and, especially, in the pelvic cavity. Some pockets of fluid were almost isolated. Quantitatively, the models can account for over 80% of the volume of the exchange (2.5 L), displaying an effective area of contact of 913-450 cm2 between parietal peritoneum and dialysate. This amounts to only 11% -21% of the anatomic area, again emphasizing the uneven distribution of dialysate. Ignoring very thin (< 0.1 mm) films of dialysate, the bulk (80%) had mean thicknesses ranging from 1.6 to 1.9 cm. Transcendental equations for bulk diffusion were then applied to these findings to determine a theoretical time for urea of about 2-3 hours to half-saturation, or 5-7 hours to 80% saturation, in the absence of convective currents. The distribution of dialysate within the peritoneal cavity is very uneven, resulting in long diffusion times in fluid pockets wherever convective currents may be minimal. Hence, intradialysate diffusion should not be ignored when modeling peritoneal dialysis.

  17. (18)F-FDG dynamic PET/CT in patients with multiple myeloma: patterns of tracer uptake and correlation with bone marrow plasma cell infiltration rate.

    PubMed

    Sachpekidis, Christos; Mai, Elias K; Goldschmidt, Hartmut; Hillengass, Jens; Hose, Dirk; Pan, Leyun; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2015-06-01

    The value of F-FDG PET in the diagnostic approach of multiple myeloma (MM) remains incompletely elicited. Little is known about the kinetics of F-FDG in the bone marrow and extramedullary sites in MM. This study aimed to evaluate quantitative data on kinetics and distribution patterns of F-FDG in MM patients with regard to pelvic bone marrow plasma cell infiltration. The study included 40 patients with primary MM. Dynamic PET/CT scanning of the lower lumbar spine and pelvis was performed after the administration of F-FDG. Whole-body PET/CT studies were performed. Sites of focal increased tracer uptake were considered as highly suggestive of myelomatous involvement after taking into account the patient history and CT findings. Bone marrow of the os ilium without pathologic tracer accumulation served as reference. The evaluation of dynamic PET/CT studies was based in addition to the conventional visual (qualitative) assessment, on semiquantitative (SUV) calculations, as well as on absolute quantitative estimations after application of a 2-tissue compartment model and a noncompartmental approach. F-FDG quantitative information and corresponding distribution patterns were correlated with pelvic bone marrow plasma cell infiltration. Fifty-two myelomatous lesions were detected in the pelvis. All parameters in suspected MM lesions ranged in significantly higher levels than in reference tissue (P < 0.01). Correlative analyses revealed that bone marrow plasma cell infiltration rate correlated significantly with SUVaverage, SUVmax, and the parameters K1, influx, and fractal dimension of F-FDG in reference bone marrow (P < 0.01). In addition, whole-body static PET/CT imaging demonstrated 4 patterns of tracer uptake; these are as follows: negative, focal, diffuse, and mixed (focal/diffuse) tracer uptake. Patients with a mixed pattern of radiotracer uptake had the highest mean plasma cell infiltration rate in their bone marrow, whereas those with negative PET/CT scans demonstrated the lowest bone marrow plasma cell infiltration. In total, 265 focal myeloma-indicative F-FDG-avid lesions were detected, 129 of which correlated with low-dose CT osteolytic findings. No significant correlation between the number of focal lesions detected in PET/CT and bone marrow infiltration was detected. The F-FDG kinetic parameters K1, influx, and fractal dimension as well as SUVaverage from reference tissue correlated significantly with bone marrow malignant plasma cell infiltration rate. Patients with negative PET/CT demonstrated the lowest bone marrow infiltration by malignant plasma cells, whereas those with a mixed pattern of tracer uptake had the highest infiltration.

  18. Dual-Energy CT in Enhancing Subdural Effusions that Masquerade as Subdural Hematomas: Diagnosis with Virtual High-Monochromatic (190-keV) Images.

    PubMed

    Bodanapally, U K; Dreizin, D; Issa, G; Archer-Arroyo, K L; Sudini, K; Fleiter, T R

    2017-10-01

    Extravasation of iodinated contrast into subdural space following contrast-enhanced radiographic studies results in hyperdense subdural effusions, which can be mistaken as acute subdural hematomas on follow-up noncontrast head CTs. Our aim was to identify the factors associated with contrast-enhancing subdural effusion, characterize diffusion and washout kinetics of iodine in enhancing subdural effusion, and assess the utility of dual-energy CT in differentiating enhancing subdural effusion from subdural hematoma. We retrospectively analyzed follow-up head dual-energy CT studies in 423 patients with polytrauma who had undergone contrast-enhanced whole-body CT. Twenty-four patients with enhancing subdural effusion composed the study group, and 24 randomly selected patients with subdural hematoma were enrolled in the comparison group. Postprocessing with syngo.via was performed to determine the diffusion and washout kinetics of iodine. The sensitivity and specificity of dual-energy CT for the diagnosis of enhancing subdural effusion were determined with 120-kV, virtual monochromatic energy (190-keV) and virtual noncontrast images. Patients with enhancing subdural effusion were significantly older (mean, 69 years; 95% CI, 60-78 years; P < .001) and had a higher incidence of intracranial hemorrhage ( P = .001). Peak iodine concentration in enhancing subdural effusions was reached within the first 8 hours of contrast administration with a mean of 0.98 mg/mL (95% CI, 0.81-1.13 mg/mL), and complete washout was achieved at 38 hours. For the presence of a hyperdense subdural collection on 120-kV images with a loss of hyperattenuation on 190-keV and virtual noncontrast images, when considered as a true-positive for enhancing subdural effusion, the sensitivity was 100% (95% CI, 85.75%-100%) and the specificity was 91.67% (95% CI, 73%-99%). Dual-energy CT has a high sensitivity and specificity in differentiating enhancing subdural effusion from subdural hematoma. Hence, dual-energy CT has a potential to obviate follow-up studies. © 2017 by American Journal of Neuroradiology.

  19. Non-Eosinophilic Nasal Polyps Shows Increased Epithelial Proliferation and Localized Disease Pattern in the Early Stage.

    PubMed

    Kim, Dong-Kyu; Jin, Hong Ryul; Eun, Kyoung Mi; Mutusamy, Somasundran; Cho, Seong H; Oh, Sohee; Kim, Dae Woo

    2015-01-01

    Non-eosinophilic nasal polyps (NPs) show less inflammatory changes and are less commonly associated with lower airway inflammatory disorders such as asthma, compared with eosinophilic NPs. However, the development of non-eosinophilic NPs which is a predominant subtype in Asian population still remains unclear. A total of 81 patients (45 with non-eosinophilic NPs and 36 with eosinophilic NPs) were enrolled. Clinical information and computed tomography (CT), endoscopic, and histological findings were investigated. Tissue samples were analyzed for total IgE levels and for mRNA expression levels of interleukin (IL)-4, IL-5, IL-13, interferon (IFN)-γ, tumor necrosis factor (TNF)-α, IL-17A, IL-22, IL-23p19, transforming growth factor (TGF)-β1, TGF-β2, TGF-β3, and periostin. Immunostaining assessment of Ki-67 as a proliferation marker was performed. We found that epithelial in-growing patterns such as pseudocysts were more frequently observed in histological and endoscopic evaluations of non-eosinophilic NPs, which was linked to increase epithelial staining of Ki-67, a proliferating marker. Eosinophilic NPs were characterized by high infiltration of inflammatory cells, compared with non-eosinophilic NPs. To investigate the developmental course of each subtype, CT was analyzed according to CT scores and subtypes. Non-eosinophilic NPs showed more localized pattern and maxillary sinus involvement, but lesser olfactory involvement in early stage whereas eosinophilic NPs were characterized by diffuse ethmoidal and olfactory involvement. In addition, high ethmoidal/maxillary (E/M) CT scores, indicating ethmoidal dominant involvement, were one of surrogate markers for eosinophilic NP. E/M CT scores was positively correlated with levels of TH2 inflammatory markers, including IL-4, IL-5, periostin mRNA expression and total IgE levels in NPs, whereas levels of the TH1 cytokine, IFN- γ were inversely correlated. Moreover, if the combinatorial algorithm meet the three of the four markers, including IL-5 (<2.379), periostin (<3.889), IFN-γ (>0.316), and E/M ratio (<2.167), non-eosinophilic CRSwNP are diagnosed with a sensitivity of 84.4% and a specificity of 84.8%. Histologic, immunologic and clinical data suggest that non-eosinophilic NPs showed enhanced epithelial alteration and more localized maxillary involvement. Combination of cutoff value on IL-5, periostin, IFN-γ, and E/M scores may be one of surrogate markers for non-eosinophil NP subtype.

  20. Four-Dimensional CT of the Diaphragm in Children: Initial Experience

    PubMed Central

    2018-01-01

    Objective To evaluate the technical feasibility of four-dimensional (4D) CT for the functional evaluation of the pediatric diaphragm. Materials and Methods In 22 consecutive children (median age 3.5 months, age range 3 days–3 years), 4D CT was performed to assess diaphragm motion. Diaphragm abnormalities were qualitatively evaluated and diaphragm motion was quantitatively measured on 4D CT. Lung density changes between peak inspiration and expiration were measured in the basal lung parenchyma. The diaphragm motions and lung density changes measured on 4D CT were compared between various diaphragm conditions. In 11 of the 22 children, chest sonography was available for comparison. Results Four-dimensional CT demonstrated normal diaphragm (n = 8), paralysis (n = 10), eventration (n = 3), and diffusely decreased motion (n = 1). Chest sonography demonstrated normal diaphragm (n = 2), paralysis (n = 6), eventration (n = 2), and right pleural effusion (n = 1). The sonographic findings were concordant with the 4D CT findings in 90.9% (10/11) of the patients. In diaphragm paralysis, the affected diaphragm motion was significantly decreased compared with the contralateral normal diaphragm motion (−1.1 ± 2.2 mm vs. 7.6 ± 3.8 mm, p = 0.005). The normal diaphragms showed significantly greater motion than the paralyzed diaphragms (4.5 ± 2.1 mm vs. −1.1 ± 2.2 mm, p < 0.0001), while the normal diaphragm motion was significantly smaller than the motion of the contralateral normal diaphragm in paralysis (4.5 ± 2.1 mm vs. 7.6 ± 3.8 mm, p = 0.01). Basal lung density change of the affected side was significantly smaller than that of the contralateral side in diaphragm paralysis (89 ± 73 Hounsfield units [HU] vs. 180 ± 71 HU, p = 0.03), while no significant differences were found between the normal diaphragms and the paralyzed diaphragms (136 ± 66 HU vs. 89 ± 73 HU, p = 0.1) or between the normal diaphragms and the contralateral normal diaphragms in paralysis (136 ± 66 HU vs. 180 ± 71 HU, p = 0.1). Conclusion The functional evaluation of the pediatric diaphragm is feasible with 4D CT in select children. PMID:29354007

  1. On the Potential Role of MRI Biomarkers of COPD to Guide Bronchoscopic Lung Volume Reduction.

    PubMed

    Adams, Colin J; Capaldi, Dante P I; Di Cesare, Robert; McCormack, David G; Parraga, Grace

    2018-02-01

    In patients with severe emphysema and poor quality of life, bronchoscopic lung volume reduction (BLVR) may be considered and guided based on lobar emphysema severity. In particular, x-ray computed tomography (CT) emphysema measurements are used to identify the most diseased and the second-most diseased lobes as BLVR targets. Inhaled gas magnetic resonance imaging (MRI) also provides chronic obstructive pulmonary disease (COPD) biomarkers of lobar emphysema and ventilation abnormalities. Our objective was to retrospectively evaluate CT and MRI biomarkers of lobar emphysema and ventilation in patients with COPD eligible for BLVR. We hypothesized that MRI would provide complementary biomarkers of emphysema and ventilation that help determine the most appropriate lung lobar targets for BLVR in patients with COPD. We retrospectively evaluated 22 BLVR-eligible patients from the Thoracic Imaging Network of Canada cohort (diffusing capacity of the lung for carbon monoxide = 37 ± 12% predicted , forced expiratory volume in 1 second = 34 ± 7% predicted , total lung capacity = 131 ± 17% predicted , and residual volume = 216 ± 36% predicted ). Lobar CT emphysema, measured using a relative area of <-950 Hounsfield units (RA 950 ) and MRI ventilation defect percent, was independently used to rank lung lobe disease severity. In 7 of 22 patients, there were different CT and MRI predictions of the most diseased lobe. In some patients, there were large ventilation defects in lobes not targeted by CT, indicative of a poorly ventilated lung. CT and MRI classification of the most diseased and the second-most diseased lobes showed a fair-to-moderate intermethod reliability (Cohen κ = 0.40-0.59). In this proof-of-concept retrospective analysis, quantitative MRI ventilation and CT emphysema measurements provided different BLVR targets in over 30% of the patients. The presence of large MRI ventilation defects in lobes next to CT-targeted lobes might also change the decision to proceed or to guide BLVR to a different lobar target. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  2. Multiscale modeling of fluid flow and mass transport

    NASA Astrophysics Data System (ADS)

    Masuoka, K.; Yamamoto, H.; Bijeljic, B.; Lin, Q.; Blunt, M. J.

    2017-12-01

    In recent years, there are some reports on a simulation of fluid flow in pore spaces of rocks using Navier-Stokes equations. These studies mostly adopt a X-ray CT to create 3-D numerical grids of the pores in micro-scale. However, results may be of low accuracy when the rock has a large pore size distribution, because pores, whose size is smaller than resolution of the X-ray CT may be neglected. We recently found out by tracer tests in a laboratory using a brine saturated Ryukyu limestone and inject fresh water that a decrease of chloride concentration took longer time. This phenomenon can be explained due to weak connectivity of the porous networks. Therefore, it is important to simulate entire pore spaces even those of very small sizes in which diffusion is dominant. We have developed a new methodology for multi-level modeling for pore scale fluid flow in porous media. The approach is to combine pore-scale analysis with Darcy-flow analysis using two types of X-ray CT images in different resolutions. Results of the numerical simulations showed a close match with the experimental results. The proposed methodology is an enhancement for analyzing mass transport and flow phenomena in rocks with complicated pore structure.

  3. Diagnosis of Richter transformation in chronic lymphocytic leukemia: histology tips the scales.

    PubMed

    Federmann, Birgit; Mueller, Martin R; Steinhilber, Julia; Horger, Marius S; Fend, Falko

    2018-06-12

    Development of diffuse large B-cell lymphoma in chronic lymphocytic leukemia, so-called Richter transformation (RT), occurs in 2-5% of patients and is associated with poor outcome. The clinical features of RT are fairly non-specific and unable to discriminate transformation from other mimics. In case of clinically suspected RT, a CT/MRT is recommended, and FDG-PET/CT may help to select the site of biopsy. Radiological features suggestive of RT have been defined, but there are only limited data about their predictive value, and histological confirmation is still considered the gold standard for RT diagnosis. We retrospectively analyzed 34 patients with clinically suspected RT and available radiological and histological data. A histopathological diagnosis of RT with concordant clinical and radiological findings was obtained in 13 patients. In 18 patients, CT did not show features of transformation, concordant with lack of RT in the biopsy. Of interest, a distinct lymphoma other than DLBCL was identified in two of these cases. A false-positive radiological diagnosis of RT was rendered in two patients, including a case of Herpes simplex virus lymphadenitis. In conclusion, our findings confirm the central role of tissue biopsy in the diagnostic work up in case of clinically suspected RT.

  4. Structure and constitution of glass and steel compound in glass-metal composite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyubimova, Olga N.; Morkovin, Andrey V.; Dryuk, Sergey A.

    2014-11-14

    The research using methods of optical and scanning electronic microscopy was conducted and it discovered common factors on structures and diffusing zone forming after welding glass C49-1 and steel Ct3sp in technological process of creating new glass-metal composite. Different technological modes of steel surface preliminary oxidation welded with and without glass were investigated. The time of welding was varied from minimum encountering time to the time of stabilizing width of diffusion zone.

  5. High resolution multidetector CT aided tissue analysis and quantification of lung fibrosis

    NASA Astrophysics Data System (ADS)

    Zavaletta, Vanessa A.; Karwoski, Ronald A.; Bartholmai, Brian; Robb, Richard A.

    2006-03-01

    Idiopathic pulmonary fibrosis (IPF, also known as Idiopathic Usual Interstitial Pneumontis, pathologically) is a progressive diffuse lung disease which has a median survival rate of less than four years with a prevalence of 15-20/100,000 in the United States. Global function changes are measured by pulmonary function tests and the diagnosis and extent of pulmonary structural changes are typically assessed by acquiring two-dimensional high resolution CT (HRCT) images. The acquisition and analysis of volumetric high resolution Multi-Detector CT (MDCT) images with nearly isotropic pixels offers the potential to measure both lung function and structure. This paper presents a new approach to three dimensional lung image analysis and classification of normal and abnormal structures in lungs with IPF.

  6. Performance of e-ASPECTS software in comparison to that of stroke physicians on assessing CT scans of acute ischemic stroke patients.

    PubMed

    Herweh, Christian; Ringleb, Peter A; Rauch, Geraldine; Gerry, Steven; Behrens, Lars; Möhlenbruch, Markus; Gottorf, Rebecca; Richter, Daniel; Schieber, Simon; Nagel, Simon

    2016-06-01

    The Alberta Stroke Program Early CT score (ASPECTS) is an established 10-point quantitative topographic computed tomography scan score to assess early ischemic changes. We compared the performance of the e-ASPECTS software with those of stroke physicians at different professional levels. The baseline computed tomography scans of acute stroke patients, in whom computed tomography and diffusion-weighted imaging scans were obtained less than two hours apart, were retrospectively scored by e-ASPECTS as well as by three stroke experts and three neurology trainees blinded to any clinical information. The ground truth was defined as the ASPECTS on diffusion-weighted imaging scored by another two non-blinded independent experts on consensus basis. Sensitivity and specificity in an ASPECTS region-based and an ASPECTS score-based analysis as well as receiver-operating characteristic curves, Bland-Altman plots with mean score error, and Matthews correlation coefficients were calculated. Comparisons were made between the human scorers and e-ASPECTS with diffusion-weighted imaging being the ground truth. Two methods for clustered data were used to estimate sensitivity and specificity in the region-based analysis. In total, 34 patients were included and 680 (34 × 20) ASPECTS regions were scored. Mean time from onset to computed tomography was 172 ± 135 min and mean time difference between computed tomographyand magnetic resonance imaging was 41 ± 31 min. The region-based sensitivity (46.46% [CI: 30.8;62.1]) of e-ASPECTS was better than three trainees and one expert (p ≤ 0.01) and not statistically different from another two experts. Specificity (94.15% [CI: 91.7;96.6]) was lower than one expert and one trainee (p < 0.01) and not statistically different to the other four physicians. e-ASPECTS had the best Matthews correlation coefficient of 0.44 (experts: 0.38 ± 0.08 and trainees: 0.19 ± 0.05) and the lowest mean score error of 0.56 (experts: 1.44 ± 1.79 and trainees: 1.97 ± 2.12). e-ASPECTS showed a similar performance to that of stroke experts in the assessment of brain computed tomographys of acute ischemic stroke patients with the Alberta Stroke Program Early CT score method. © 2016 World Stroke Organization.

  7. Statistical CT noise reduction with multiscale decomposition and penalized weighted least squares in the projection domain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang Shaojie; Tang Xiangyang; School of Automation, Xi'an University of Posts and Telecommunications, Xi'an, Shaanxi 710121

    2012-09-15

    Purposes: The suppression of noise in x-ray computed tomography (CT) imaging is of clinical relevance for diagnostic image quality and the potential for radiation dose saving. Toward this purpose, statistical noise reduction methods in either the image or projection domain have been proposed, which employ a multiscale decomposition to enhance the performance of noise suppression while maintaining image sharpness. Recognizing the advantages of noise suppression in the projection domain, the authors propose a projection domain multiscale penalized weighted least squares (PWLS) method, in which the angular sampling rate is explicitly taken into consideration to account for the possible variation ofmore » interview sampling rate in advanced clinical or preclinical applications. Methods: The projection domain multiscale PWLS method is derived by converting an isotropic diffusion partial differential equation in the image domain into the projection domain, wherein a multiscale decomposition is carried out. With adoption of the Markov random field or soft thresholding objective function, the projection domain multiscale PWLS method deals with noise at each scale. To compensate for the degradation in image sharpness caused by the projection domain multiscale PWLS method, an edge enhancement is carried out following the noise reduction. The performance of the proposed method is experimentally evaluated and verified using the projection data simulated by computer and acquired by a CT scanner. Results: The preliminary results show that the proposed projection domain multiscale PWLS method outperforms the projection domain single-scale PWLS method and the image domain multiscale anisotropic diffusion method in noise reduction. In addition, the proposed method can preserve image sharpness very well while the occurrence of 'salt-and-pepper' noise and mosaic artifacts can be avoided. Conclusions: Since the interview sampling rate is taken into account in the projection domain multiscale decomposition, the proposed method is anticipated to be useful in advanced clinical and preclinical applications where the interview sampling rate varies.« less

  8. Jejunal diverticulitis in a healthy 91-year-old man.

    PubMed

    Kagolanu, Deepthi Chaitanya; Subhani, Miral; Novick, Daniel; Rizvon, Kaleem

    2018-05-30

    A 91-year-old African American man was admitted with sudden onset diffuse abdominal pain which radiated to the right flank. CT of the abdomen with contrast showed diverticula in the jejunum with adjacent inflammation and microperforation that was contained. Conservative therapy similar to colonic diverticulitis was effective. Although rare, our case highlights the importance of having an early and high suspicion for jejunal diverticulitis when patients present with non-specific abdominal symptoms in order to avoid perforation. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. An assessment of the cost-effectiveness of magnetic resonance, including diffusion-weighted imaging, in patients with transient ischaemic attack and minor stroke: a systematic review, meta-analysis and economic evaluation.

    PubMed

    Wardlaw, Joanna; Brazzelli, Miriam; Miranda, Hector; Chappell, Francesca; McNamee, Paul; Scotland, Graham; Quayyum, Zahid; Martin, Duncan; Shuler, Kirsten; Sandercock, Peter; Dennis, Martin

    2014-04-01

    Patients with transient ischaemic attack (TIA) or minor stroke need rapid treatment of risk factors to prevent recurrent stroke. ABCD2 score or magnetic resonance diffusion-weighted brain imaging (MR DWI) may help assessment and treatment. Is MR with DWI cost-effective in stroke prevention compared with computed tomography (CT) brain scanning in all patients, in specific subgroups or as 'one-stop' brain-carotid imaging? What is the current UK availability of services for stroke prevention? Published literature; stroke registries, audit and randomised clinical trials; national databases; survey of UK clinical and imaging services for stroke; expert opinion. Systematic reviews and meta-analyses of published/unpublished data. Decision-analytic model of stroke prevention including on a 20-year time horizon including nine representative imaging scenarios. The pooled recurrent stroke rate after TIA (53 studies, 30,558 patients) is 5.2% [95% confidence interval (CI) 3.9% to 5.9%] by 7 days, and 6.7% (5.2% to 8.7%) at 90 days. ABCD2 score does not identify patients with key stroke causes or identify mimics: 66% of specialist-diagnosed true TIAs and 35-41% of mimics had an ABCD2 score of ≥ 4; 20% of true TIAs with ABCD2 score of < 4 had key risk factors. MR DWI (45 studies, 9078 patients) showed an acute ischaemic lesion in 34.3% (95% CI 30.5% to 38.4%) of TIA, 69% of minor stroke patients, i.e. two-thirds of TIA patients are DWI negative. TIA mimics (16 studies, 14,542 patients) make up 40-45% of patients attending clinics. UK survey (45% response) showed most secondary prevention started prior to clinic, 85% of primary brain imaging was same-day CT; 51-54% of patients had MR, mostly additional to CT, on average 1 week later; 55% omitted blood-sensitive MR sequences. Compared with 'CT scan all patients' MR was more expensive and no more cost-effective, except for patients presenting at > 1 week after symptoms to diagnose haemorrhage; strategies that triaged patients with low ABCD2 scores for slow investigation or treated DWI-negative patients as non-TIA/minor stroke prevented fewer strokes and increased costs. 'One-stop' CT/MR angiographic-plus-brain imaging was not cost-effective. Data on sensitivity/specificity of MR in TIA/minor stroke, stroke costs, prognosis of TIA mimics and accuracy of ABCD2 score by non-specialists are sparse or absent; all analysis had substantial heterogeneity. Magnetic resonance with DWI is not cost-effective for secondary stroke prevention. MR was most helpful in patients presenting at > 1 week after symptoms if blood-sensitive sequences were used. ABCD2 score is unlikely to facilitate patient triage by non-stroke specialists. Rapid specialist assessment, CT brain scanning and identification of serious underlying stroke causes is the most cost-effective stroke prevention strategy. The National Institute for Health Research Health Technology Assessment programme.

  10. Performance of hybrid system for fluorescence and micro-computed tomography in synchronous mode

    NASA Astrophysics Data System (ADS)

    Liu, Xin; Zhang, Yi; Liu, Fei; Guo, Xiaolian; Wang, Xin; Bai, Jing

    2010-11-01

    Fluorescence diffuse optical tomography (FDOT) plays an important role in studying physiological and pathological processes of small animals in vivo. The low spatial resolution, however, limits the ability of FDOT in resolving the biodistributions of fluorescent markers. The anatomical information provided by X-ray computed tomography (CT) can be used to improve the image quality of FDOT. However, in most hybrid FDOT/CT systems, the projection data sets of optics and X-ray are acquired sequentially, which increases the acquisition time and bring in the unwanted soft tissue displacement. In this paper, we evaluate the performance of a synchronous FDOT/CT system, which allows for faster and concurrent imaging. Compared with previous FDOT/CT systems, the two subsystems (FDOT and CT) acquire projection images in synchronous mode, so the body position can keep consistent in the same projection data acquired by both subsystems. The experimental results of phantom and in vivo experiments suggest that the reconstruction quality of FDOT can be significantly improved when structural a priori information is utilized to constrain the reconstruction process. On the other hand, the synchronous FDOT/CT system decreases the imaging time.

  11. Role of the Charge-Transfer State in Reduced Langevin Recombination in Organic Solar Cells: A Theoretical Study

    PubMed Central

    2015-01-01

    Reduced Langevin recombination has been observed in organic solar cells (OSCs) for many years, but its origin is still unclear. A recent work by Burke et al. (Adv. Energy Mater.2015, 5, 1500123-1) was inspired by this reduced Langevin recombination, and they proposed an equilibrium model of charge-transfer (CT) states that correlates the open-circuit voltage of OSCs with experimentally available device parameters. In this work, we extend Burke et al.’s CT model further and for the first time directly correlate the reduced Langevin recombination with the energetic and dynamic behavior of the CT state. Recombination through CT states leads in a straightforward manner to a decrease in the Langevin reduction factor with increasing temperature, without explicit consideration of the temperature dependence of the mobility. To verify the correlation between the CT states and reduced Langevin recombination, we incorporated this CT model and the reduced Langevin model into drift-diffusion simulations of a bilayer OSC. The simulations not only successfully reproduced realistic current–voltage (J–V) characteristics of the bilayer OSC, but also demonstrate that the two models consistently lead to same value of the apparent Langevin reduction factor. PMID:26640611

  12. Assessing pharmacokinetics of indocyanine green-loaded nanoparticle in tumor with a dynamic diffuse fluorescence tomography system

    NASA Astrophysics Data System (ADS)

    Zhang, Yanqi; Yin, Guoyan; Zhao, Huijuan; Ma, Wenjuan; Gao, Feng; Zhang, Limin

    2018-02-01

    Real-time and continuous monitoring of drug release in vivo is an important task in pharmaceutical development. Here, we devoted to explore a real-time continuous study of the pharmacokinetics of free indocyanine green (ICG) and ICG loaded in the shell-sheddable nanoparticles in tumor based on a dynamic diffuse fluorescence tomography (DFT) system: A highly-sensitive dynamic DFT system of CT-scanning mode generates informative and instantaneous sampling datasets; An analysis procedure extracts the pharmacokinetic parameters from the reconstructed time curves of the mean ICG concentration in tumor, using the Gauss-Newton scheme based on two-compartment model. Compared with the pharmacokinetic parameters of free ICG in tumor, the ICG loaded in the shell-sheddable nanoparticles shows efficient accumulation in tumor. The results demonstrate our proposed dynamic-DFT can provide an integrated and continuous view of the drug delivery of the injected agents in different formulations, which is helpful for the development of diagnosis and therapy for tumors.

  13. A Case Report of Cannabis Induced Hemoptysis

    PubMed Central

    Hashmi, Hafiz Rizwan Talib; Duncalf, Richard; Khaja, Misbahuddin

    2016-01-01

    Abstract As the principal route of marijuana use is by inhalation, potential harmful consequences on pulmonary structure and function can be anticipated. Here, we present a case of hemoptysis attributed to smoking cannabis in a 38-year-old man. The patient experienced an episode of hemoptysis and shortness of breath immediately after smoking marijuana. Chest radiograph and computed tomography (CT) scans of the chest showed bilateral diffuse ground-glass opacities. A fiber optic bronchoscopy confirmed bilateral diffuse bleeding from respiratory tract. Additional evaluation of hemoptysis indicated no infection or immunological responses. Urine toxicology was positive for cannabis. Chronic marijuana smoking causes visible and microscopic injury to the larger airways responsible for symptoms or chronic bronchitis. We review the beneficial and deleterious effects of marijuana and describe a case of significant hemoptysis attributed to smoking marijuana. In addition to other respiratory complications of marijuana use, physicians should educate their patients about this potentially lethal effect of marijuana smoking in the form of hemoptysis. PMID:27043693

  14. [Gastric perforation caused by primary gastric diffuse large B cell lymphoma].

    PubMed

    Kim, Ju Seok; Rou, Woo Sun; Ahn, Byung Moo; Moon, Hee Seok; Kang, Sun Hyung; Sung, Jae Kyu; Jeong, Hyun Yong; Song, Kyu-Sang

    2015-01-01

    Spontaneous gastric perforation is a rare complication of gastric lymphoma that is potentially life threatening since it can progress to sepsis and multi-organ failure. Morbidity also increases due to prolonged hospitalization and delay in initiating chemotherapy. Therefore prompt diagnosis and appropriate treatment is critical to improve prognosis. A 64-year-old man presented to the emergency department with severe abdominal pain. Chest X-ray showed free air below the right diaphragm. Abdominal CT scan also demonstrated free air in the peritoneal cavity with large wall defect in the lesser curvature of gastric lower body. Therefore, the patient underwent emergency operation and primary closure was done. Pathologic specimen obtained during surgery was compatible to diffuse large B cell lymphoma. Fifteen days after primary closure, the patient received subtotal gastrectomy and chemotherapy was initiated after recovery. Patient is currently being followed-up at outpatient department without any particular complications. Herein, we report a rare case of gastric lymphoma that initially presented as peritonitis because of spontaneous gastric perforation.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shum, Andrew D.; Parkinson, Dilworth Y.; Xiao, Xianghui

    The performance of polymer-electrolyte fuel cells is heavily dependent on proper management of liquid water. One particular reason is that liquid water can collect in the gas diffusion layers (GDLs) blocking the reactant flow to the catalyst layer. This results in increased mass-transport losses. At higher temperatures, evaporation of water becomes a dominant water-removal mechanism and specifically phase-change-induced (PCI) flow is present due to thermal gradients. This study used synchrotron based micro X-ray computed tomography (CT) to visualize and quantify the water distribution within gas diffusion layers subject to a thermal gradient. Plotting saturation as a function of through-plane distancemore » quantitatively shows water redistribution, where water evaporates at hotter locations and condenses in colder locations. The morphology of the 2 GDLs on the micro-scale, as well as evaporating water clusters, are resolved, indicating that the GDL voids are slightly prolate, whereas water clusters are oblate. From the mean radii of water distributions and visual inspection, it is observed that larger water clusters evaporate faster than smaller ones.« less

  16. ¹⁸F-FDG PET/CT: a review of diagnostic and prognostic features in multiple myeloma and related disorders.

    PubMed

    Dammacco, Franco; Rubini, Giuseppe; Ferrari, Cristina; Vacca, Angelo; Racanelli, Vito

    2015-02-01

    Conventional radiographic skeletal survey has been for many years the gold standard to detect the occurrence of osteolytic lesions in patients with multiple myeloma (MM). However, the introduction of more sensitive imaging procedures has resulted in an updated anatomic and functional Durie and Salmon "plus" staging system and has remarkably changed the diagnostic and prognostic approach to this tumor. It is now established that (18)fluorine-fluorodeoxyglucose ((18)F-FDG) positron-emission tomography (PET) combined with low-dose computed tomography (CT), shortly designated PET/CT, exhibits a higher screening and diagnostic sensitivity and specificity over the skeleton X-ray. In patients with monoclonal gammopathy of undetermined significance and in those with smoldering MM, PET/CT is consistently unable to detect focal and/or diffuse marrow abnormalities. Conversely, based on a systematic review of 18 studies comprising almost 800 MM patients, PET/CT was able to detect MM osteolytic lesions with a sensitivity of approximately 80-90% and a specificity of 80-100%. Importantly, a poor degree of concordance has also been emphasized between PET/CT and whole-body magnetic resonance imaging (WB-MRI) in that when both techniques were applied to the same patients, double-positive results were recorded in approximately 30% of the cases, but in the majority of them, a higher number of lesions were revealed with PET/CT than with MRI. Double-negative results, on the other hand, were found in about 22% of the patients. Because PET/CT is able to identify tumor foci throughout the body, it can be usefully applied to the study of solitary bone plasmacytoma and extra-medullary plasmacytoma: In both conditions, the detection of additional, previously overlooked sites of skeletal involvement would falsify the diagnosis of single-district disease, upstage the tumor, and therefore require a different therapeutic approach. In addition, although PET/CT is poorly sensitive to diffuse bone marrow infiltration, it can anticipate a site of impending fracture throughout the body and can discriminate old from new pathologic fractures. MRI should, however, be preferred when vertebral bodies are suspected to be involved and the risk of vertebral fracture is to be assessed. PET/CT is a sensitive and reliable procedure to evaluate the response to chemotherapy and/or radiotherapy, which is shown by a remarkable reduction and sometimes total disappearance of FDG accumulation in the involved bony structures, although these structures remain morphologically abnormal. Conversely, an increased focal uptake of FDG in apparent remission patients often precedes clinically overt relapse. PET/CT should be preferred to other imaging techniques to assess the remission status after autologous stem cell transplantation. In patients with primary and remission-induced non-secretory MM, the use of PET/CT may help to early detect single or multiple districts of focal non-secretory relapse. Osteonecrosis of the jaw, its location, and extent in MM patients receiving bis-phosphonates are better defined by both PET/CT and contrast-enhanced MRI compared with dental panoramic views derived from cone beam CT imaging. Little is known as to the possible role of PET/CT in the assessment of disease extension, tumor load, and response to therapy in patients with Waldenström's macroglobulinemia (WM). In a study conducted on 35 WM patients, comparative PET/CT before and after therapy was able to detect positive findings in 83% of the patients, in contrast with the previous results achieved with conventional imaging that reported visceral involvement in much lower percentages. Similarly scanty are the data on the use of PET/CT in localized and systemic amyloidosis, given the small number of patients studied so far. A retrospective study has shown that, at variance from (123)Iodine-serum amyloid P component ((123)I-SAP) scintigraphy, which was found to be positive in about one-third of the patients with localized amyloidosis, an increased FDG uptake was detected at the amyloid site in virtually all of them. On the contrary, none of the patients with systemic amyloidosis showed an increased FDG uptake in sites of known deposition, whereas (123)I-SAP scintigraphy tested positive in the large majority of them. In another study, however, no such remarkable difference of positive PET/CT scans between localized and systemic amyloidosis was reported. Finally, false-positive and false-negative PET/CT findings can occur in different conditions that should be kept in mind to avoid wrong or omitted diagnoses.

  17. Optical imaging: new tools for arthritis.

    PubMed

    Chamberland, David; Jiang, Yebin; Wang, Xueding

    2010-10-01

    Conventional radiography, ultrasound, CT, MRI, and nuclear imaging are the current imaging modalities used for clinical evaluation of arthritis which is highly prevalent and a leading cause of disability. Some of these types of imaging are also used for monitoring disease progression and treatment response of arthritis. However, their disadvantages limit their utilities, such as ionizing radiation for radiography, CT, and nuclear imaging; suboptimal tissue contrast resolution for radiography, CT, ultrasound, and nuclear imaging; high cost for CT and MRI and nuclear imaging; and long data-acquisition time with ensuing patient discomfort for MRI. Recently, there have been considerable advances in nonionizing noninvasive optical imaging which has demonstrated promise for early diagnosis, monitoring therapeutic interventions and disease progression of arthritis. Optical based molecular imaging modalities such as fluorescence imaging have shown high sensitivity in detection of optical contrast agents and can aid early diagnosis and ongoing evaluation of chronic inflammatory arthritis. Optical transillumination imaging or diffuse optical tomography may differentiate normal joint clear synovial fluid from turbid and pink medium early in the inflammatory process. Fourier transform infrared spectroscopy has been used to evaluate fluid composition from joints affected by arthritis. Hemodynamic changes such as angiogenesis, hypervascularization, and hypoxia in arthritic articular tissue can potentially be observed by diffuse optical tomography and photoacoustic tomography. Optical measurements could also facilitate quantification of hemodynamic properties such as blood volume and oxygenation levels at early stages of inflammatory arthritis. Optical imaging provides methodologies which should contribute to detection of early changes and monitoring of progression in pathological characteristics of arthritis, with relatively simple instrumentation.

  18. Cranial computed tomography and real-time sonography in full-term neonates and infants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siegel, M.J.; Patel, J.; Gado, M.H.

    1983-10-01

    The results of cranial ultrasonography (US) and computed tomography (CT) were compared in 52 full-term neonates and young infants. The chief indications for examination included: increasing head size, dysmorphic features, myelomeningocele, inflammatory disease, and asphyxia. Disorders detected included hydrocephalus, parenchymal abnormalities, intracranial hemorrhage, extraparenchymal fluid collections, and vascular and other developmental malformations. CT and US essentially were equivalent in detecting hydrocephalus, moderate to large intraventricular hemorrhages or subdural collections, and large focal parenchymal lesions, although CT was somewhat better in determining the level and cause of obstruction in patients with hydrocephalus and characterizing parenchymal abnormalities. CT was more sensitive thanmore » ultrasound in detecting subarachnoid hemorrhage (100% vs. 0%), diffuse parenchymal abnormality (100% vs. 33%), and small intraventricular hemorrhages (100% vs. 0%) but these lesions often were not clinically significant. The results suggest that US should be used as the primary neuroradiological examination in term infants; CT probably should be reserved for further investigation after US in those patients with a history of hypoxia and progressive clinical deterioration.« less

  19. Direct reconstruction in CT-analogous pharmacokinetic diffuse fluorescence tomography: two-dimensional simulative and experimental validations

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Zhang, Yanqi; Zhang, Limin; Li, Jiao; Zhou, Zhongxing; Zhao, Huijuan; Gao, Feng

    2016-04-01

    We present a generalized strategy for direct reconstruction in pharmacokinetic diffuse fluorescence tomography (DFT) with CT-analogous scanning mode, which can accomplish one-step reconstruction of the indocyanine-green pharmacokinetic-rate images within in vivo small animals by incorporating the compartmental kinetic model into an adaptive extended Kalman filtering scheme and using an instantaneous sampling dataset. This scheme, compared with the established indirect and direct methods, eliminates the interim error of the DFT inversion and relaxes the expensive requirement of the instrument for obtaining highly time-resolved date-sets of complete 360 deg projections. The scheme is validated by two-dimensional simulations for the two-compartment model and pilot phantom experiments for the one-compartment model, suggesting that the proposed method can estimate the compartmental concentrations and the pharmacokinetic-rates simultaneously with a fair quantitative and localization accuracy, and is well suitable for cost-effective and dense-sampling instrumentation based on the highly-sensitive photon counting technique.

  20. Preliminary experiments on pharmacokinetic diffuse fluorescence tomography of CT-scanning mode

    NASA Astrophysics Data System (ADS)

    Zhang, Yanqi; Wang, Xin; Yin, Guoyan; Li, Jiao; Zhou, Zhongxing; Zhao, Huijuan; Gao, Feng; Zhang, Limin

    2016-10-01

    In vivo tomographic imaging of the fluorescence pharmacokinetic parameters in tissues can provide additional specific and quantitative physiological and pathological information to that of fluorescence concentration. This modality normally requires a highly-sensitive diffuse fluorescence tomography (DFT) working in dynamic way to finally extract the pharmacokinetic parameters from the measured pharmacokinetics-associated temporally-varying boundary intensity. This paper is devoted to preliminary experimental validation of our proposed direct reconstruction scheme of instantaneous sampling based pharmacokinetic-DFT: A highly-sensitive DFT system of CT-scanning mode working with parallel four photomultiplier-tube photon-counting channels is developed to generate an instantaneous sampling dataset; A direct reconstruction scheme then extracts images of the pharmacokinetic parameters using the adaptive-EKF strategy. We design a dynamic phantom that can simulate the agent metabolism in living tissue. The results of the dynamic phantom experiments verify the validity of the experiment system and reconstruction algorithms, and demonstrate that system provides good resolution, high sensitivity and quantitativeness at different pump speed.

  1. De novo status epilepticus with isolated aphasia.

    PubMed

    Flügel, Dominique; Kim, Olaf Chan-Hi; Felbecker, Ansgar; Tettenborn, Barbara

    2015-08-01

    Sudden onset of aphasia is usually due to stroke. Rapid diagnostic workup is necessary if reperfusion therapy is considered. Ictal aphasia is a rare condition but has to be excluded. Perfusion imaging may differentiate acute ischemia from other causes. In dubious cases, EEG is required but is time-consuming and laborious. We report a case where we considered de novo status epilepticus as a cause of aphasia without any lesion even at follow-up. A 62-year-old right-handed woman presented to the emergency department after nurses found her aphasic. She had undergone operative treatment of varicosis 3 days earlier. Apart from hypertension and obesity, no cardiovascular risk factors and no intake of medication other than paracetamol were reported. Neurological examination revealed global aphasia and right pronation in the upper extremity position test. Computed tomography with angiography and perfusion showed no abnormalities. Electroencephalogram performed after the CT scan showed left-sided slowing with high-voltage rhythmic 2/s delta waves but no clear ictal pattern. Intravenous lorazepam did improve EEG slightly, while aphasia did not change. Lumbar puncture was performed which likely excluded encephalitis. Magnetic resonance imaging showed cortical pathological diffusion imaging (restriction) and cortical hyperperfusion in the left parietal region. Intravenous anticonvulsant therapy under continuous EEG resolved neurological symptoms. The patient was kept on anticonvulsant therapy. Magnetic resonance imaging after 6 months showed no abnormalities along with no clinical abnormalities. Magnetic resonance imaging findings were only subtle, and EEG was without clear ictal pattern, so the diagnosis of aphasic status remains with some uncertainty. However, status epilepticus can mimic stroke symptoms and has to be considered in patients with aphasia even when no previous stroke or structural lesions are detectable and EEG shows no epileptic discharges. Epileptic origin is favored when CT or MR imaging reveal no hypoperfusion. In this case, MRI was superior to CT in detecting hyperperfusion. This article is part of a Special Issue entitled "Status Epilepticus". Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Crossing Fibers Detection with an Analytical High Order Tensor Decomposition

    PubMed Central

    Megherbi, T.; Kachouane, M.; Oulebsir-Boumghar, F.; Deriche, R.

    2014-01-01

    Diffusion magnetic resonance imaging (dMRI) is the only technique to probe in vivo and noninvasively the fiber structure of human brain white matter. Detecting the crossing of neuronal fibers remains an exciting challenge with an important impact in tractography. In this work, we tackle this challenging problem and propose an original and efficient technique to extract all crossing fibers from diffusion signals. To this end, we start by estimating, from the dMRI signal, the so-called Cartesian tensor fiber orientation distribution (CT-FOD) function, whose maxima correspond exactly to the orientations of the fibers. The fourth order symmetric positive definite tensor that represents the CT-FOD is then analytically decomposed via the application of a new theoretical approach and this decomposition is used to accurately extract all the fibers orientations. Our proposed high order tensor decomposition based approach is minimal and allows recovering the whole crossing fibers without any a priori information on the total number of fibers. Various experiments performed on noisy synthetic data, on phantom diffusion, data and on human brain data validate our approach and clearly demonstrate that it is efficient, robust to noise and performs favorably in terms of angular resolution and accuracy when compared to some classical and state-of-the-art approaches. PMID:25246940

  3. FDG-PET Imaging in Hematological Malignancies

    PubMed Central

    Valls, L.; Badve, C.; Avril, S.; Herrmann, K.; Faulhaber, P.; O'Donnell, J.; Avril, N.

    2016-01-01

    The majority of aggressive lymphomas is characterized by an up regulated glycolytic activity, which enables the visualization by F-18 FDG-PET/CT. One-stop hybrid FDG-PET/CT combines the functional and morphologic information, outperforming both, CT and FDG-PET as separate imaging modalities. This has resulted in several recommendations using FDG-PET/CT for staging, restaging, monitoring during therapy, and assessment of treatment response as well as identification of malignant transformation. FDG-PET/CT may obviate the need for a bone marrow biopsy in patients with Hodgkin's lymphoma and diffuse large B-cell lymphoma. FDG-PET/CT response assessment is recommended for FDG-avid lymphomas, whereas CT-based response evaluation remains important in lymphomas with low or variable FDG avidity. The treatment induced change in metabolic activity allows for assessment of response after completion of therapy as well as prediction of outcome early during therapy. The five point scale Deauville Criteria allows the assessment of treatment response based on visual FDG-PET analysis. Although the use of FDG-PET/CT for prediction of therapeutic response is promising it should only be conducted in the context of clinical trials. Surveillance FDG-PET/CT after complete remission is discouraged due to the relative high number of false-positive findings, which in turn may result in further unnecessary investigations. Future directions include the use of new PET tracers such as F-18 fluorothymidine (FLT), a surrogate biomarker of cellular proliferation and Ga-68 CXCR4, a chemokine receptor imaging biomarker as well as innovative digital PET/CT and PET/MRI techniques. PMID:27090170

  4. PET/CT versus bone marrow biopsy in the initial evaluation of bone marrow infiltration in various pediatric malignancies.

    PubMed

    Zapata, Claudia P; Cuglievan, Branko; Zapata, Catalina M; Olavarrieta, Raquel; Raskin, Scott; Desai, Kavita; De Angulo, Guillermo

    2018-02-01

    Accurate staging is essential in the prognosis and management of pediatric malignancies. Current protocols require screening for marrow infiltration with bone marrow biopsy (BMB) as the gold standard. Positron emission tomography-computed tomography (PET-CT) is commonly used to complete the staging process and can also be used to evaluate marrow infiltration. To compare PET-CT and BMB in the initial evaluation of bone marrow infiltration in pediatric cancers. We retrospectively reviewed new cases of EWS, rhabdomyosarcoma, neuroblastoma, and lymphoma diagnosed between January 2009 and October 2014. Each case had undergone both PET-CT and BMB within 4 weeks without treatment in the interval between screening modalities. We reviewed 69 cases. Bone marrow infiltration was demonstrated in 34 cases by PET-CT and in 18 cases by BMB. The sensitivity and negative predictive value of PET-CT were both 100%. Interestingly, the cases in which infiltration was not detected on BMB had an abnormal marrow signal on PET-CT focal or distant to iliac crest. PET-CT has a high sensitivity when assessing marrow infiltration in pediatric malignancies. Advances in radiologic modalities may obviate the use of invasive, painful, and costly procedures like BMB. Furthermore, biopsy results are limited by insufficient tissue or the degree of marrow infiltration (diffuse vs. focal disease). PET-CT can improve the precision of biopsy when used as a guiding tool. This study proposes the use of PET-CT as first-line screening for bone marrow infiltration to improve the accuracy of staging in new diagnoses. © 2017 Wiley Periodicals, Inc.

  5. Diffuse idiopathic pulmonary neuroendocrine cell hyperplasia: Report of two cases.

    PubMed

    García-Fontán, Eva; Blanco Ramos, Montserrat; García, Jose Soro; Carrasco, Rommel; Cañizares, Miguel Ángel; González Piñeiro, Ana

    2018-05-19

    Diffuse idiopathic pulmonary neuroendocrine cell hyperplasia (DIPNECH) is a rare disorder characterized by a proliferation of neuroendocrine cells within the lung. It is classically described as a disease with persistent cough, dyspnea and wheezing in non-smoker middle aged females. CT of the chest reveals diffuse air trapping with mosaic pattern. We present two cases of DIPNECH that were sent to our department to perform a lung biopsy with the diagnostic suspicion of diffuse interstitial disease. Both cases were women with a history of chronic cough and moderate effort dyspnea. The aim of this paper is that physicians take into account this diagnostic entity before treating as an asthmatic a patient with these characteristics, not forgetting that they are prenoplastic lesions. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  6. Simultaneous whole body 18F-fluorodeoxyglucose positron emission tomography magnetic resonance imaging for evaluation of pediatric cancer: Preliminary experience and comparison with 18F-fluorodeoxyglucose positron emission tomography computed tomography

    PubMed Central

    Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S

    2016-01-01

    AIM: To describe our preliminary experience with simultaneous whole body 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. METHODS: This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated 18F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. RESULTS: A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was significantly lower than that of benign lesions (1246.2 + 417.3; P = 0.0003; Student’s t test). A range of ADCmin thresholds for malignancy were evaluated, from 0.5-1.5 × 10-3 mm2/s. The 1.0 × 10-3 ADCmin threshold performed best compared with PET-CT reference (68.3% accuracy). However, the accuracy of PET-MRI SUVmax was significantly better than ADCmin for detecting malignant lesions compared with PET-CT reference (P < 0.0001; two-tailed McNemar’s test). CONCLUSION: These results suggest a clinical role for simultaneous whole body PET-MRI in evaluating pediatric cancer patients. PMID:27028112

  7. Simultaneous whole body (18)F-fluorodeoxyglucose positron emission tomography magnetic resonance imaging for evaluation of pediatric cancer: Preliminary experience and comparison with (18)F-fluorodeoxyglucose positron emission tomography computed tomography.

    PubMed

    Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S

    2016-03-28

    To describe our preliminary experience with simultaneous whole body (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated (18)F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was significantly lower than that of benign lesions (1246.2 + 417.3; P = 0.0003; Student's t test). A range of ADCmin thresholds for malignancy were evaluated, from 0.5-1.5 × 10(-3) mm(2)/s. The 1.0 × 10(-3) ADCmin threshold performed best compared with PET-CT reference (68.3% accuracy). However, the accuracy of PET-MRI SUVmax was significantly better than ADCmin for detecting malignant lesions compared with PET-CT reference (P < 0.0001; two-tailed McNemar's test). These results suggest a clinical role for simultaneous whole body PET-MRI in evaluating pediatric cancer patients.

  8. Pulmonary artery segmentation and quantification in sickle cell associated pulmonary hypertension

    NASA Astrophysics Data System (ADS)

    Linguraru, Marius George; Mukherjee, Nisha; Van Uitert, Robert L.; Summers, Ronald M.; Gladwin, Mark T.; Machado, Roberto F.; Wood, Bradford J.

    2008-03-01

    Pulmonary arterial hypertension is a known complication associated with sickle-cell disease; roughly 75% of sickle cell disease-afflicted patients have pulmonary arterial hypertension at the time of death. This prospective study investigates the potential of image analysis to act as a surrogate for presence and extent of disease, and whether the size change of the pulmonary arteries of sickle cell patients could be linked to sickle-cell associated pulmonary hypertension. Pulmonary CT-Angiography scans from sickle-cell patients were obtained and retrospectively analyzed. Randomly selected pulmonary CT-Angiography studies from patients without sickle-cell anemia were used as negative controls. First, images were smoothed using anisotropic diffusion. Then, a combination of fast marching and geodesic active contours level sets were employed to segment the pulmonary artery. An algorithm based on fast marching methods was used to compute the centerline of the segmented arteries. From the centerline, the diameters at the pulmonary trunk and first branch of the pulmonary arteries were measured automatically. Arterial diameters were normalized to the width of the thoracic cavity, patient weight and body surface. Results show that the pulmonary trunk and first right and left pulmonary arterial branches at the pulmonary trunk junction are significantly larger in diameter with increased blood flow in sickle-cell anemia patients as compared to controls (p values of 0.0278 for trunk and 0.0007 for branches). CT with image processing shows great potential as a surrogate indicator of pulmonary hemodynamics or response to therapy, which could be an important tool for drug discovery and noninvasive clinical surveillance.

  9. X-ray tomography as a non-destructive tool for evaluating the preservation of primary isotope signatures and mineralogy of Mesozoic fossils

    NASA Astrophysics Data System (ADS)

    Santillan, J. D.; Boyce, J. W.; Eagle, R.; Martin, T.; Tuetken, T.; Eiler, J.

    2010-12-01

    The stable isotope compositions of carbonate and phosphate components in fossil teeth and bone are widely used to infer information on paleoclimate and the physiology of extinct organisms. Recently the potential for measuring the body temperatures of extinct vertebrates from analyses of 13C-18O bond ordering in fossil teeth has been demonstrated (Eagle et al. 2010). The interpretation of these isotopic signatures relies on an assessment of the resistance of fossil bioapatite to alteration, as diffusion within, and partial recrystallization, or replacement of the original bioapatite will lead to measured compositions that represent mixtures between primary and secondary phases and/or otherwise inaccurate apparent temperatures. X-ray computed tomography (CT) allows 3-D density maps of teeth to be made at micron-scale resolution. Such density maps have the potential to record textural evidence for alteration, recrystallization, or replacement of enamel. Because it is non-destructive, CT can be used prior to stable isotope analysis to identify potentially problematic samples without consuming or damaging scientifically significant specimens. As a test, we have applied CT to tooth fragments containing both dentin and enamel from Late Jurassic sauropods and a Late Cretaceous theropod that yielded a range of clumped isotope temperatures from anomalously high ˜60oC to physiologically plausible ≤40oC. This range of temperatures suggests partial, high-temperature modification of some specimens, but possible preservation of primary signals in others. Three-dimensional CT volumes generated using General Electric Phoenix|x-ray CT instruments were compared with visible light and back-scattered electron images of the same samples. The tube-detector combination used for the CT study consisted of a 180 kV nanofocus transmission tube coupled with a 127 micron pixel pitch detector ( ˜3-12μ m voxel edges), allowing us to clearly map out alteration zones in high contrast, while reducing edge effects and beam hardening artifacts. CT images of these teeth show a range of replacement textures. One tooth -- thought to be the least altered -- shows only localized positive density anomalies near fractures, while a second -- thought to be highly altered -- contains high-density replacement mineralization. A third tooth -- one suspected of possible partial alteration -- shows a network of rectilinear density anomalies in the enamel similar to 2-D transmitted light and back-scattered electron images. This may represent recrystallization or replacement of the primary bioapatite. Unlike 2-D imaging techniques, 3-D volumes can be used to quickly and easily make quantitative measurements of the volumes of altered and unaltered materials: For example, in the enamel of sample 3, we observe a ratio of high density to low density material of ˜ 3:2.

  10. Knowledge diffusion in the collaboration hypernetwork

    NASA Astrophysics Data System (ADS)

    Yang, Guang-Yong; Hu, Zhao-Long; Liu, Jian-Guo

    2015-02-01

    As knowledge constitutes a primary productive force, it is important to understand the performance of knowledge diffusion. In this paper, we present a knowledge diffusion model based on the local-world non-uniform hypernetwork, which introduces the preferential diffusion mechanism and the knowledge absorptive capability αj, where αj is correlated with the hyperdegree dH(j) of node j. At each time step, we randomly select a node i as the sender; a receiver node is selected from the set of nodes that the sender i has published with previously, with probability proportional to the number of papers they have published together. Applying the average knowledge stock V bar(t) , the variance σ2(t) and the variance coefficient c(t) of knowledge stock to measure the growth and diffusion of knowledge and the adequacy of knowledge diffusion, we have made 3 groups of comparative experiments to investigate how different network structures, hypernetwork sizes and knowledge evolution mechanisms affect the knowledge diffusion, respectively. As the diffusion mechanisms based on the hypernetwork combine with the hyperdegree of node, the hypernetwork is more suitable for investigating the performance of knowledge diffusion. Therefore, the proposed model could be helpful for deeply understanding the process of the knowledge diffusion in the collaboration hypernetwork.

  11. Unusual Radiographic Presentation of Pneumocystis Pneumonia in a Patient with AIDS.

    PubMed

    Block, Brian L; Mehta, Tejas; Ortiz, Gabriel M; Ferris, Sean P; Vu, Thienkhai H; Huang, Laurence; Cattamanchi, Adithya

    2017-01-01

    Pneumocystis jirovecii pneumonia (PCP) typically presents as an interstitial and alveolar process with ground glass opacities on chest computed tomography (CT). The absence of ground glass opacities on chest CT is thought to have a high negative predictive value for PCP in individuals with AIDS. Here, we report a case of PCP in a man with AIDS who presented to our hospital with subacute shortness of breath and a nonproductive cough. While his chest CT revealed diffuse nodular rather than ground glass opacities, bronchoscopy with bronchoalveolar lavage and transbronchial biopsies confirmed the diagnosis of PCP and did not identify additional pathogens. PCP was not the expected diagnosis based on chest CT, but it otherwise fit well with the patient's clinical and laboratory presentation. In the era of combination antiretroviral therapy, routine prophylaxis for PCP, and increased use of computed tomography, it may be that PCP will increasingly present with nonclassical chest radiographic patterns. Clinicians should be aware of this presentation when selecting diagnostic and management strategies.

  12. Unusual Radiographic Presentation of Pneumocystis Pneumonia in a Patient with AIDS

    PubMed Central

    Mehta, Tejas; Ortiz, Gabriel M.; Ferris, Sean P.; Vu, Thienkhai H.; Huang, Laurence; Cattamanchi, Adithya

    2017-01-01

    Pneumocystis jirovecii pneumonia (PCP) typically presents as an interstitial and alveolar process with ground glass opacities on chest computed tomography (CT). The absence of ground glass opacities on chest CT is thought to have a high negative predictive value for PCP in individuals with AIDS. Here, we report a case of PCP in a man with AIDS who presented to our hospital with subacute shortness of breath and a nonproductive cough. While his chest CT revealed diffuse nodular rather than ground glass opacities, bronchoscopy with bronchoalveolar lavage and transbronchial biopsies confirmed the diagnosis of PCP and did not identify additional pathogens. PCP was not the expected diagnosis based on chest CT, but it otherwise fit well with the patient's clinical and laboratory presentation. In the era of combination antiretroviral therapy, routine prophylaxis for PCP, and increased use of computed tomography, it may be that PCP will increasingly present with nonclassical chest radiographic patterns. Clinicians should be aware of this presentation when selecting diagnostic and management strategies. PMID:29362681

  13. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    PubMed

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  14. Synchronous Changes of Cortical Thickness and Corresponding White Matter Microstructure During Brain Development Accessed by Diffusion MRI Tractography from Parcellated Cortex

    PubMed Central

    Jeon, Tina; Mishra, Virendra; Ouyang, Minhui; Chen, Min; Huang, Hao

    2015-01-01

    Cortical thickness (CT) changes during normal brain development is associated with complicated cellular and molecular processes including synaptic pruning and apoptosis. In parallel, the microstructural enhancement of developmental white matter (WM) axons with their neuronal bodies in the cerebral cortex has been widely reported with measurements of metrics derived from diffusion tensor imaging (DTI), especially fractional anisotropy (FA). We hypothesized that the changes of CT and microstructural enhancement of corresponding axons are highly interacted during development. DTI and T1-weighted images of 50 healthy children and adolescents between the ages of 7 and 25 years were acquired. With the parcellated cortical gyri transformed from T1-weighted images to DTI space as the tractography seeds, probabilistic tracking was performed to delineate the WM fibers traced from specific parcellated cortical regions. CT was measured at certain cortical regions and FA was measured from the WM fibers traced from same cortical regions. The CT of all frontal cortical gyri, including Brodmann areas 4, 6, 8, 9, 10, 11, 44, 45, 46, and 47, decreased significantly and heterogeneously; concurrently, significant, and heterogeneous increases of FA of WM traced from corresponding regions were found. We further revealed significant correlation between the slopes of the CT decrease and the slopes of corresponding WM FA increase in all frontal cortical gyri, suggesting coherent cortical pruning and corresponding WM microstructural enhancement. Such correlation was not found in cortical regions other than frontal cortex. The molecular and cellular mechanisms of these synchronous changes may be associated with overlapping signaling pathways of axonal guidance, synaptic pruning, neuronal apoptosis, and more prevalent interstitial neurons in the prefrontal cortex. Revealing the coherence of cortical and WM structural changes during development may open a new window for understanding the underlying mechanisms of developing brain circuits and structural abnormality associated with mental disorders. PMID:26696839

  15. Traumatic midline subarachnoid hemorrhage on initial computed tomography as a marker of severe diffuse axonal injury.

    PubMed

    Mata-Mbemba, Daddy; Mugikura, Shunji; Nakagawa, Atsuhiro; Murata, Takaki; Ishii, Kiyoshi; Kushimoto, Shigeki; Tominaga, Teiji; Takahashi, Shoki; Takase, Kei

    2018-01-05

    OBJECTIVE The objective of this study was to test the hypothesis that midline (interhemispheric or perimesencephalic) traumatic subarachnoid hemorrhage (tSAH) on initial CT may implicate the same shearing mechanism that underlies severe diffuse axonal injury (DAI). METHODS The authors enrolled 270 consecutive patients (mean age [± SD] 43 ± 23.3 years) with a history of head trauma who had undergone initial CT within 24 hours and brain MRI within 30 days. Six initial CT findings, including intraventricular hemorrhage (IVH) and tSAH, were used as candidate predictors of DAI. The presence of tSAH was determined at the cerebral convexities, sylvian fissures, sylvian vallecula, cerebellar folia, interhemispheric fissure, and perimesencephalic cisterns. Following MRI, patients were divided into negative and positive DAI groups, and were assigned to a DAI stage: 1) stage 0, negative DAI; 2) stage 1, DAI in lobar white matter or cerebellum; 3) stage 2, DAI involving the corpus callosum; and 4) stage 3, DAI involving the brainstem. Glasgow Outcome Scale-Extended (GOSE) scores were obtained in 232 patients. RESULTS Of 270 patients, 77 (28.5%) had DAI; tSAH and IVH were independently associated with DAI (p < 0.05). Of tSAH locations, midline tSAH was independently associated with both overall DAI and DAI stage 2 or 3 (severe DAI; p < 0.05). The midline tSAH on initial CT had sensitivity of 60.8%, specificity of 81.7%, and positive and negative predictive values of 43.7% and 89.9%, respectively, for severe DAI. When adjusted for admission Glasgow Coma Score, the midline tSAH independently predicted poor GOSE score at both hospital discharge and after 6 months. CONCLUSIONS Midline tSAH could implicate the same shearing mechanism that underlies severe DAI, for which midline tSAH on initial CT is a probable surrogate.

  16. Deploying swarm intelligence in medical imaging identifying metastasis, micro-calcifications and brain image segmentation.

    PubMed

    al-Rifaie, Mohammad Majid; Aber, Ahmed; Hemanth, Duraiswamy Jude

    2015-12-01

    This study proposes an umbrella deployment of swarm intelligence algorithm, such as stochastic diffusion search for medical imaging applications. After summarising the results of some previous works which shows how the algorithm assists in the identification of metastasis in bone scans and microcalcifications on mammographs, for the first time, the use of the algorithm in assessing the CT images of the aorta is demonstrated along with its performance in detecting the nasogastric tube in chest X-ray. The swarm intelligence algorithm presented in this study is adapted to address these particular tasks and its functionality is investigated by running the swarms on sample CT images and X-rays whose status have been determined by senior radiologists. In addition, a hybrid swarm intelligence-learning vector quantisation (LVQ) approach is proposed in the context of magnetic resonance (MR) brain image segmentation. The particle swarm optimisation is used to train the LVQ which eliminates the iteration-dependent nature of LVQ. The proposed methodology is used to detect the tumour regions in the abnormal MR brain images.

  17. Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dyk, Pawel; Jiang, Naomi; Sun, Baozhou

    2014-11-15

    Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodesmore » by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.« less

  18. Segmentation-less Digital Rock Physics

    NASA Astrophysics Data System (ADS)

    Tisato, N.; Ikeda, K.; Goldfarb, E. J.; Spikes, K. T.

    2017-12-01

    In the last decade, Digital Rock Physics (DRP) has become an avenue to investigate physical and mechanical properties of geomaterials. DRP offers the advantage of simulating laboratory experiments on numerical samples that are obtained from analytical methods. Potentially, DRP could allow sparing part of the time and resources that are allocated to perform complicated laboratory tests. Like classic laboratory tests, the goal of DRP is to estimate accurately physical properties of rocks like hydraulic permeability or elastic moduli. Nevertheless, the physical properties of samples imaged using micro-computed tomography (μCT) are estimated through segmentation of the μCT dataset. Segmentation proves to be a challenging and arbitrary procedure that typically leads to inaccurate estimates of physical properties. Here we present a novel technique to extract physical properties from a μCT dataset without the use of segmentation. We show examples in which we use segmentation-less method to simulate elastic wave propagation and pressure wave diffusion to estimate elastic properties and permeability, respectively. The proposed method takes advantage of effective medium theories and uses the density and the porosity that are measured in the laboratory to constrain the results. We discuss the results and highlight that segmentation-less DRP is more accurate than segmentation based DRP approaches and theoretical modeling for the studied rock. In conclusion, the segmentation-less approach here presented seems to be a promising method to improve accuracy and to ease the overall workflow of DRP.

  19. Changes in neuroendocrine elements in bronchial mucosa in chronic lung disease in adults.

    PubMed

    Pilmane, M; Luts, A; Sundler, F

    1995-05-01

    It is not clear whether there is any association between metaplasia of the bronchial epithelium and changes in the distribution of neuroendocrine cells. This study examined, by immunohistological techniques, the distribution of neuroendocrine cells and juxtamucoscal nerve fibres in bronchial biopsies showing metaplastic changes. Bronchial biopsies from 12 subjects with epithelial metaplasia associated with bronchiectasis and diffuse pulmonary fibrosis were examined by conventional light microscopy and immunohistological techniques for protein gene product 9.5 (PGP), chromogranin A and B (CAB), serotonin, vasoactive intestinal peptide (VIP), substance P (SP), calcitonin gene-related peptide (CGRP), calcitonin (CT), and gastrin releasing peptide (GRP). Regions of non-metaplastic epithelium contained numerous PGP and serotonin immunoreactive cells. Sub-populations of these cells displayed CAB, CGRP, CT, and GRP immunoreactivity. Metaplastic epithelium contained only a few weakly stained PGP, serotonin, CAB, GRP, CT and CGRP immunoreactive cells in six cases. Metaplastic epithelium was characterised by a high number of CAB-containing cells in six cases and in these biopsies prominent PGP-containing nerve bundles were seen in the subepithelial layer beneath the metaplastic epithelium. The distribution patterns of neuroendocrine cells and neuronal elements vary between areas of normal and metaplastic epithelium and within areas of metaplastic epithelium. Neuronal hyperplasia was associated with an increase in the number of CAB-containing cells within the metaplastic epithelium.

  20. Changes in neuroendocrine elements in bronchial mucosa in chronic lung disease in adults.

    PubMed Central

    Pilmane, M.; Luts, A.; Sundler, F.

    1995-01-01

    BACKGROUND--It is not clear whether there is any association between metaplasia of the bronchial epithelium and changes in the distribution of neuroendocrine cells. This study examined, by immunohistological techniques, the distribution of neuroendocrine cells and juxtamucoscal nerve fibres in bronchial biopsies showing metaplastic changes. METHODS--Bronchial biopsies from 12 subjects with epithelial metaplasia associated with bronchiectasis and diffuse pulmonary fibrosis were examined by conventional light microscopy and immunohistological techniques for protein gene product 9.5 (PGP), chromogranin A and B (CAB), serotonin, vasoactive intestinal peptide (VIP), substance P (SP), calcitonin gene-related peptide (CGRP), calcitonin (CT), and gastrin releasing peptide (GRP). RESULTS--Regions of non-metaplastic epithelium contained numerous PGP and serotonin immunoreactive cells. Sub-populations of these cells displayed CAB, CGRP, CT, and GRP immunoreactivity. Metaplastic epithelium contained only a few weakly stained PGP, serotonin, CAB, GRP, CT and CGRP immunoreactive cells in six cases. Metaplastic epithelium was characterised by a high number of CAB-containing cells in six cases and in these biopsies prominent PGP-containing nerve bundles were seen in the subepithelial layer beneath the metaplastic epithelium. CONCLUSIONS--The distribution patterns of neuroendocrine cells and neuronal elements vary between areas of normal and metaplastic epithelium and within areas of metaplastic epithelium. Neuronal hyperplasia was associated with an increase in the number of CAB-containing cells within the metaplastic epithelium. Images PMID:7541167

  1. Imipenem/cilastatin-induced acute eosinophilic pneumonia.

    PubMed

    Foong, Kap Sum; Lee, Ashley; Pekez, Marijeta; Bin, Wei

    2016-03-04

    Drugs, toxins, and infections are known to cause acute eosinophilic pneumonia. Daptomycin and minocycline are the commonly reported antibiotics associated with acute eosinophilic pneumonia. In this study, we present a case of imipenem/cilastatin-induced acute eosinophilic pneumonia. The patient presented with fever, acute hypoxic respiratory distress, and diffuse ground-glass opacities on the chest CT a day after the initiation of imipenem/cilastatin. Patient also developed peripheral eosinophilia. A reinstitution of imipenem/cilastatin resulted in recurrence of the signs and symptoms. A bronchoscopy with bronchoalveolar lavage showed 780 nucleated cells/mm(3) with 15% eosinophil. The patient's clinical condition improved significantly after the discontinuation of imipenem/cilastatin therapy and the treatment with corticosteroid. 2016 BMJ Publishing Group Ltd.

  2. Comparison of DWI and 18F-FDG PET/CT for assessing preoperative N-staging in gastric cancer: evidence from a meta-analysis.

    PubMed

    Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo

    2017-10-13

    The diagnostic values of diffusion weighted imaging (DWI) and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73-0.85), 0.69 (0.61-0.77), and 0.81 (0.77-0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39-0.64), 0.88 (0.61-0.97), and 0.66 (0.62-0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18 F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18 F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18 F-FDG PET/CT had limited utility for preoperative N-staging.

  3. [A case of cerebral fat embolism after artificial bone replacement operation for femoral head fracture].

    PubMed

    Kontani, Satoru; Nakamura, Akinobu; Tokumi, Hiroshi; Hirose, Genjirou

    2014-01-01

    A 83 years old woman was slipped and injured with right femoral neck fracture. After three days from the fracture, she underwent an artificial head bone replacement operation. Immediately after surgery, she complained of chest discomfort, nausea and dyspnea. A few hours later, she became comatose. Brain CT showed no abnormality and clinical diagnosis of heart failure was made without pulmonary embolism on enhanced chest CT. Magnetic resonance imaging (MRI) of the brain next day showed multiple small patchy hyperintense lesion in bilateral hemispheres on diffusion-weighted images (DWI), producing a "star field pattern''. Based on Criteria of Gurd, this patient had one major criterion and four minor criteria. And according to the Criteria of Schonfeld, this patient had 5 points, consistent with clinical diagnosis of fat embolism. Because of these criteria, she was diagnosed as cerebral fat embolism syndrome. We started supported care and edaravon. Two weeks after surgery, her condition recovered and remaind to stuporous state even six month after surgery. We experienced a typical case of cerebral fat embolism, after bone surgery with diagnostic findings on MRI-DWI. Diagnosis of cerebral fat embolism syndrome requires a history of long bone fracture and/or replacing surgery with typical finding on MRI images, such as "star field pattern''.

  4. Intracranial solitary fibrous tumor: imaging findings.

    PubMed

    Clarençon, Frédéric; Bonneville, Fabrice; Rousseau, Audrey; Galanaud, Damien; Kujas, Michèle; Naggara, Olivier; Cornu, Philippe; Chiras, Jacques

    2011-11-01

    To study the neuroimaging features of intracranial solitary fibrous tumors (ISFTs). Retrospective study of neuroimaging features of 9 consecutive histopathologically proven ISFT cases. Location, size, shape, density, signal intensity and gadolinium uptake were studied at CT and MRI. Data collected from diffusion-weighted imaging (DWI) (3 patients), perfusion imaging and MR spectroscopy (2 patients), and DSA (4 patients) were also analyzed. The tumors most frequently arose from the intracranial meninges (7/9), while the other lesions were intraventricular. Tumor size ranged from 2.5 to 10 cm (mean=6.6 cm). They presented multilobular shape in 6/9 patients. Most ISFTs were heterogeneous (7/9) with areas of low T2 signal intensity that strongly enhanced after gadolinium administration (6/8). Erosion of the skull was present in about half of the cases (4/9). Components with decreased apparent diffusion coefficient were seen in 2/3 ISFTs on DWI. Spectroscopy revealed elevated peaks of choline and myo-inositol. MR perfusion showed features of hyperperfusion. ISFT should be considered in cases of extra-axial, supratentorial, heterogeneous, hypervascular tumor. Areas of low T2 signal intensity that strongly enhance after gadolinium injection are suggestive of this diagnosis. Restricted diffusion and elevated peak of myo-inositol may be additional valuable features. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  5. Age-related changes in the thymus gland: CT-pathologic correlation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, A.V.; Korobkin, M.; Olanow, W.

    1983-08-01

    Recent reports suggest that computed tomography (CT) is useful for thymoma detection in patients with myasthenia gravis. However, that usefulness may be conditioned by the state of the normal thymus. To examine this concept, the CT findings in 64 consecutive patients with histologic confirmation of thymic status after thymectomy or thymic biopsy during mediastinal exploration were reviewed. The normal thymus has a bilobed, arrowhead-shaped cross section at all ages, with gradual focal or diffuse fatty infiltration of the parenchyma usually occurring between 20 and 40 years of age. A thymoma is usually a spherical or oval mass, often producing amore » focal, distinct bulge in the adjacent pleural reflection. The differentiation of thymoma from normal thymus should be possible in most patients if age-related changes in the normal gland are appreciated.« less

  6. Diffuse malignant pleural mesothelioma in an urban hospital: Clinical spectrum and trend in incidence over time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shepherd, K.E.; Oliver, L.C.; Kazemi, H.

    1989-01-01

    This retrospective analysis reviews the clinical experience of a major urban referral hospital with diffuse malignant pleural mesothelioma during the 14-year period from 1973 through 1986. Seventy-five cases of definite or equivocal mesothelioma were identified. There were four cases of primary malignant peritoneal mesothelioma, seven cases of benign fibrous mesothelioma, and 64 cases of diffuse malignant pleural mesothelioma. In 43 cases (67%) of diffuse malignant pleural mesothelioma, there was historic evidence of asbestos exposure. In 21 cases (33%), there was no known history of asbestos exposure. An increase in annual incidence of diffuse malignant pleural mesothelioma was observed over themore » study period, from three cases in 1973 to ten cases in 1986. Despite greater awareness of this disease, the diagnosis remains a difficult one to establish given the nonspecific symptoms, signs and radiographic appearance, variable histologic appearance, and poor diagnostic sensitivity and specificity of thoracentesis and closed pleural biopsy. Thoracotomy, thoracoscopy, and CT-guided needle biopsies gave higher yields and are the diagnostic measures of choice when diffuse malignant pleural mesothelioma is suspected.« less

  7. Prognostic Value of Bone Marrow Tracer Uptake Pattern in Baseline PET Scans in Hodgkin Lymphoma: Results from an International Collaborative Study.

    PubMed

    Zwarthoed, Colette; El-Galaly, Tarec Cristoffer; Canepari, Maria; Ouvrier, Matthieu John; Viotti, Julien; Ettaiche, Marc; Viviani, Simonetta; Rigacci, Luigi; Trentin, Livio; Rusconi, Chiara; Luminari, Stefano; Cantonetti, Maria; Bolis, Silvia; Borra, Anna; Darcourt, Jacques; Salvi, Flavia; Subocz, Edyta; Tajer, Joanna; Kulikowski, Waldemar; Malkowski, Bogdan; Zaucha, Jan Maciej; Gallamini, Andrea

    2017-08-01

    PET/CT-ascertained bone marrow involvement (BMI) constitutes the single most important reason for upstaging by PET/CT in Hodgkin lymphoma (HL). However, BMI assessment in PET/CT can be challenging. This study analyzed the clinicopathologic correlations and prognostic meaning of different patterns of bone marrow (BM) 18 F-FDG uptake in HL. Methods: One hundred eighty newly diagnosed early unfavorable and advanced-stage HL patients, all scanned at baseline and after 2 adriamycin-bleomycin-vinblastine-dacarbazine (ABVD) courses with 18 F-FDG PET, enrolled in 2 international studies aimed at assessing the role of interim PET scanning in HL, were retrospectively included. Patients were treated with ABVD × 4-6 cycles and involved-field radiation when needed, and no treatment adaptation on interim PET scanning was allowed. Two masked reviewers independently reported the scans. Results: Thirty-eight patients (21.1%) had focal lesions (fPET + ), 10 of them with a single (unifocal) and 28 with multiple (multifocal) BM lesions. Fifty-three patients (29.4%) had pure strong (>liver) diffuse uptake (dPET + ) and 89 (48.4%) showed no or faint (≤liver) BM uptake (nPET + ). BM biopsy was positive in 6 of 38 patients (15.7%) for fPET + , in 1 of 53 (1.9%) for dPET + , and in 5 of 89 (5.6%) for nPET + dPET + was correlated with younger age, higher frequency of bulky disease, lower hemoglobin levels, higher leukocyte counts, and similar diffuse uptake in the spleen. Patients with pure dPET + had a 3-y progression-free survival identical to patients without any 18 F-FDG uptake (82.9% and 82.2%, respectively, P = 0.918). However, patients with fPET+ (either unifocal or multifocal) had a 3-y progression-free survival significantly inferior to patients with dPET+ and nPET+ (66.7% and 82.5%, respectively, P = 0.03). The κ values for interobserver agreement were 0.84 for focal uptake and 0.78 for diffuse uptake. Conclusion: We confirmed that 18 F-FDG PET scanning is a reliable tool for BMI assessment in HL, and BM biopsy is no longer needed for routine staging. Moreover, the interobserver agreement for BMI in this study proved excellent and only focal 18 F-FDG BM uptake should be considered as a harbinger of HL. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  8. Compaction bands in high temperature/pressure diagenetically altered unconventional shale gas reservoirs

    NASA Astrophysics Data System (ADS)

    Regenauer-Lieb, K.; Veveakis, M.; Poulet, T.

    2014-12-01

    Unconventional energy and mineral resources are typically trapped in a low porosity/permeability environment and are difficult to produce. An extreme end-member is the shale gas reservoir in the Cooper Basin (Australia) that is located at 3500-4000 m depth and ambient temperature conditions around 200oC. Shales of lacustrine origin (with high clay content) are diagenetically altered. Diagenesis involves fluid release mineral reactions of the general type Asolid ↔ Bsolid +Cfluid and switches on suddenly in the diagenetic window between 100-200oC. Diagenetic reactions can involve concentrations of smectite, aqueous silica compound, illite, potassium ions, aqueous silica, quartz, feldspar, kerogen, water and gas . In classical petroleum engineering such interlayer water/gas release reactions are considered to cause cementation and significantly reduce porosity and permeability. Yet in contradiction to the expected permeability reduction gas is successfully being produced. We propose that the success is based on the ductile equivalent of classical compaction bands in solid mechanics. The difference being that that the rate of the volumetric compaction is controlled by the diagenetic reactions. Ductile compaction bands are forming high porosity fluid channels rather than low porosity crushed grains in the solid mechanical equivalent. We show that this new type of volumetric instability appears in rate-dependent heterogenous materials as Cnoidal waves. These are nonlinear and exact periodic stationary waves, well known in the shallow water theory of fluid mechanics. Their distance is a direct function of the hydromechanical diffusivities. These instabilities only emerge in low permeability environment where the fluid diffusivity is about an order of magnitude lower than the mechanical loading. The instabilities are expected to be of the type as shown in the image below. The image shows a CT-scan of a laboratory experiment kindly provided by Papamichos (pers.comm.). Periodic compaction bands are clearly detected by the CT analysis of a shale sample compressed under high confining pressure.

  9. Metabolomics of Breast Cancer Using High-Resolution Magic Angle Spinning Magnetic Resonance Spectroscopy: Correlations with 18F-FDG Positron Emission Tomography-Computed Tomography, Dynamic Contrast-Enhanced and Diffusion-Weighted Imaging MRI.

    PubMed

    Yoon, Haesung; Yoon, Dahye; Yun, Mijin; Choi, Ji Soo; Park, Vivian Youngjean; Kim, Eun-Kyung; Jeong, Joon; Koo, Ja Seung; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Suhkmann; Kim, Min Jung

    2016-01-01

    Our goal in this study was to find correlations between breast cancer metabolites and conventional quantitative imaging parameters using high-resolution magic angle spinning (HR-MAS) magnetic resonance spectroscopy (MRS) and to find breast cancer subgroups that show high correlations between metabolites and imaging parameters. Between August 2010 and December 2013, we included 53 female patients (mean age 49.6 years; age range 32-75 years) with a total of 53 breast lesions assessed by the Breast Imaging Reporting and Data System. They were enrolled under the following criteria: breast lesions larger than 1 cm in diameter which 1) were suspicious for malignancy on mammography or ultrasound (US), 2) were pathologically confirmed to be breast cancer with US-guided core-needle biopsy (CNB) 3) underwent 3 Tesla MRI with dynamic contrast-enhanced (DCE) and diffusion-weighted imaging (DWI) and positron emission tomography-computed tomography (PET-CT), and 4) had an attainable immunohistochemistry profile from CNB. We acquired spectral data by HR-MAS MRS with CNB specimens and expressed the data as relative metabolite concentrations. We compared the metabolites with the signal enhancement ratio (SER), maximum standardized FDG uptake value (SUV max), apparent diffusion coefficient (ADC), and histopathologic prognostic factors for correlation. We calculated Spearman correlations and performed a partial least squares-discriminant analysis (PLS-DA) to further classify patient groups into subgroups to find correlation differences between HR-MAS spectroscopic values and conventional imaging parameters. In a multivariate analysis, the PLS-DA models built with HR-MAS MRS metabolic profiles showed visible discrimination between high and low SER, SUV, and ADC. In luminal subtype breast cancer, compared to all cases, high SER, ADV, and SUV were more closely clustered by visual assessment. Multiple metabolites were correlated with SER and SUV in all cases. Multiple metabolites showed correlations with SER and SUV in the ER positive, HER2 negative, and Ki-67 negative groups. High levels of PC, choline, and glycine acquired from HR-MAS MRS using CNB specimens were noted in the high SER group via DCE MRI and the high SUV group via PET-CT, with significant correlations between choline and SER and between PC and SUV. Further studies should investigate whether HR-MAS MRS using CNB specimens can provide similar or more prognostic information than conventional quantitative imaging parameters.

  10. Multimodality CT/SPECT Evaluation of Micelle Drug Carriers for Treatment of Breast Tumors

    DTIC Science & Technology

    2007-07-01

    lap diffusion, Dh and Df, were then calculated using non-linear least squares parameter estimation ( Matlab 7.1). Dh and Df were estimated using release... entanglement serves as a much greater impediment to drug transport. 3.4. Mechanism of action of cell death induced by β-lap micelles Growth assays

  11. LABORATORY AND FIELD EVALUATION OF CRYSTALLIZED DOW 704 OIL ON THE PERFORMANCE OF THE PM2.5 WINS FRACTIONATOR

    EPA Science Inventory

    Subsequent to the PM2.5 FRM's 1997 promulgation, technicians at the CT Dept. of Env. Protection observed that the DOW 704 diffusion oil used in the method's WINS fractionator would occasionally crystallize during field use - particularly under wintertime conditions. While the f...

  12. Pancreatic Neuroendocrine Tumor with Atypical Radiologic Presentation.

    PubMed

    Singh, Ramandeep; Calhoun, Sean; Shin, Minchul; Katz, Robert

    2008-01-01

    An atypical radiographic presentation of a rare non-functional pancreatic neuroendocrine tumor as seen on US, CT and MRI is described. Radiographic-pathologic correlation via gross autopsy specimens and immuno-histochemical staining demonstrates the pancreas to be markedly enlarged with extensive calcifications and numerous tiny cysts secondary to diffuse neoplastic infiltration without a focal mass.

  13. Imaging of brain metastases.

    PubMed

    Fink, Kathleen R; Fink, James R

    2013-01-01

    Imaging plays a key role in the diagnosis of central nervous system (CNS) metastasis. Imaging is used to detect metastases in patients with known malignancies and new neurological signs or symptoms, as well as to screen for CNS involvement in patients with known cancer. Computed tomography (CT) and magnetic resonance imaging (MRI) are the key imaging modalities used in the diagnosis of brain metastases. In difficult cases, such as newly diagnosed solitary enhancing brain lesions in patients without known malignancy, advanced imaging techniques including proton magnetic resonance spectroscopy (MRS), contrast enhanced magnetic resonance perfusion (MRP), diffusion weighted imaging (DWI), and diffusion tensor imaging (DTI) may aid in arriving at the correct diagnosis. This image-rich review discusses the imaging evaluation of patients with suspected intracranial involvement and malignancy, describes typical imaging findings of parenchymal brain metastasis on CT and MRI, and provides clues to specific histological diagnoses such as the presence of hemorrhage. Additionally, the role of advanced imaging techniques is reviewed, specifically in the context of differentiating metastasis from high-grade glioma and other solitary enhancing brain lesions. Extra-axial CNS involvement by metastases, including pachymeningeal and leptomeningeal metastases is also briefly reviewed.

  14. Mapping the microvascular and the associated absolute values of oxy-hemoglobin concentration through turbid media via local off-set diffuse optical imaging

    NASA Astrophysics Data System (ADS)

    Chen, Chen; Klämpfl, Florian; Stelzle, Florian; Schmidt, Michael

    2014-11-01

    An imging resolution of micron-scale has not yet been discovered by diffuse optical imaging (DOI), while a superficial response was eliminated. In this work, we report on a new approach of DOI with a local off-set alignment to subvert the common boundary conditions of the modified Beer-Lambert Law (MBLL). It can resolve a superficial target in micron scale under a turbid media. To validate both major breakthroughs, this system was used to recover a subsurface microvascular mimicking structure under an skin equivalent phantom. This microvascular was included with oxy-hemoglobin solution in variant concentrations to distiguish the absolute values of CtRHb and CtHbO2 . Experimental results confirmed the feasibility of recovering the target vascular of 50 µm in diameter, and graded the values of the concentrations of oxy-hemoglobin from 10 g/L to 50 g/L absolutely. Ultimately, this approach could evolve into a non-invasive imaging system to map the microvascular pattern and the associated oximetry under a human skin in-vivo.

  15. Innovation in hepatic alveolar echinococcosis imaging: best use of old tools, and necessary evaluation of new ones

    PubMed Central

    Liu, Wenya; Delabrousse, Éric; Blagosklonov, Oleg; Wang, Jing; Zeng, Hongchun; Jiang, Yi; Wang, Jian; Qin, Yongde; Vuitton, Dominique Angèle; Wen, Hao

    2014-01-01

    Hepatic Alveolar Echinococcosis (HAE), caused by larvae of Echinococcus multilocularis, is a rare but potentially lethal parasitic disease. The first diagnostic suspicion is usually based on hepatic ultrasound exam performed because of abdominal symptoms or in the context of a general checkup; HAE diagnosis may thus also be an incidental finding on imaging. The next step should be Computed Tomography (CT) or Magnetic Resonance Imaging (MRI). They play an important role in the initial assessment of the disease; with chest and brain imaging, they are necessary to assess the PNM stage (parasite lesion, neighboring organ invasion, metastases) of a patient with AE. Performed at least yearly, they also represent key exams for long-term follow-up after therapeutic interventions. Familiarity of radiologists with HAE imaging findings, especially in the endemic regions, will enable earlier diagnosis and more effective treatment. Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is currently considered to be the only noninvasive, albeit indirect, tool for the detection of metabolic activity in AE. Delayed acquisition of images (3 hrs after FDG injection) enhances its sensitivity for the assessment of lesion metabolism and its reliability for the continuation/withdrawal of anti-parasite treatment. However, sophisticated equipment and high cost widely limit PET/CT use for routine evaluation. Preliminary studies show that new techniques, such as contrast-enhanced ultrasound (US), Dual Energy CT or Spectral CT, and Diffusion-Weighted MRI, might also be useful in detecting the blood supply and metabolism of lesions. However, they cannot be recommended before further evaluation of their reliability in a larger number of patients with a variety of locations and stages of AE lesions. PMID:25531446

  16. Gd-EOB-DTPA-enhanced magnetic resonance imaging for bile duct intraductal papillary mucinous neoplasms

    PubMed Central

    Ying, Shi-Hong; Teng, Xiao-Dong; Wang, Zhao-Ming; Wang, Qi-Dong; Zhao, Yi-Lei; Chen, Feng; Xiao, Wen-Bo

    2015-01-01

    AIM: To investigate gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) of intraductal papillary mucinous neoplasms of the bile duct (IPMN-B). METHODS: The imaging findings of five cases of IPMN-B which were pathologically confirmed at our hospital between March 2012 and May 2013 were retrospectively analyzed. Three of these cases were diagnosed by duodenal endoscopy and biopsy pathology, and two cases were diagnosed by surgical pathology. All five patients underwent enhanced and non-enhanced computed tomography (CT), magnetic resonance cholangiopancreatography, and Gd-EOB-DTPA-enhanced MRI; one case underwent both Gd-EOB-DTPA-enhanced MRI and positron emission tomography-CT. The clinical data and imaging results for these cases were compared and are presented. RESULTS: Conventional imaging showed diffuse dilatation of bile ducts and multiple intraductal polypoid and papillary neoplasms or serrated changes along the bile ducts. In two cases, Gd-EOB-DTPA-enhanced MRI revealed dilated biliary ducts and intraductal tumors, as well as filling defects caused by mucin in the dilated bile ducts in the hepatobiliary phase. Gd-EOB-DTPA-enhanced MRI in one case clearly showed a low-signal tumor in the hepatobiliary phase, similar to what was seen by positron emission tomography-CT. In two patients, routine inspection was unable to discern whether the lesions were inflammation or tumors. However, Gd-EOB-DTPA-enhanced MRI revealed a pattern of gradual enhancement during the hepatobiliary phase, and the signal intensity of the lesions was lower than the surrounding liver parenchyma, suggesting tissue inflammation in both cases, which were confirmed by surgical pathology. CONCLUSION: Gd-EOB-DTPA-enhanced MRI reveals the intraductal mucin component of IPMN-B in some cases and the extent of tumor infiltration beyond the bile ducts in invasive cases. PMID:26167082

  17. Gd-EOB-DTPA-enhanced magnetic resonance imaging for bile duct intraductal papillary mucinous neoplasms.

    PubMed

    Ying, Shi-Hong; Teng, Xiao-Dong; Wang, Zhao-Ming; Wang, Qi-Dong; Zhao, Yi-Lei; Chen, Feng; Xiao, Wen-Bo

    2015-07-07

    To investigate gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) of intraductal papillary mucinous neoplasms of the bile duct (IPMN-B). The imaging findings of five cases of IPMN-B which were pathologically confirmed at our hospital between March 2012 and May 2013 were retrospectively analyzed. Three of these cases were diagnosed by duodenal endoscopy and biopsy pathology, and two cases were diagnosed by surgical pathology. All five patients underwent enhanced and non-enhanced computed tomography (CT), magnetic resonance cholangiopancreatography, and Gd-EOB-DTPA-enhanced MRI; one case underwent both Gd-EOB-DTPA-enhanced MRI and positron emission tomography-CT. The clinical data and imaging results for these cases were compared and are presented. Conventional imaging showed diffuse dilatation of bile ducts and multiple intraductal polypoid and papillary neoplasms or serrated changes along the bile ducts. In two cases, Gd-EOB-DTPA-enhanced MRI revealed dilated biliary ducts and intraductal tumors, as well as filling defects caused by mucin in the dilated bile ducts in the hepatobiliary phase. Gd-EOB-DTPA-enhanced MRI in one case clearly showed a low-signal tumor in the hepatobiliary phase, similar to what was seen by positron emission tomography-CT. In two patients, routine inspection was unable to discern whether the lesions were inflammation or tumors. However, Gd-EOB-DTPA-enhanced MRI revealed a pattern of gradual enhancement during the hepatobiliary phase, and the signal intensity of the lesions was lower than the surrounding liver parenchyma, suggesting tissue inflammation in both cases, which were confirmed by surgical pathology. Gd-EOB-DTPA-enhanced MRI reveals the intraductal mucin component of IPMN-B in some cases and the extent of tumor infiltration beyond the bile ducts in invasive cases.

  18. Gaussian diffusion sinogram inpainting for X-ray CT metal artifact reduction.

    PubMed

    Peng, Chengtao; Qiu, Bensheng; Li, Ming; Guan, Yihui; Zhang, Cheng; Wu, Zhongyi; Zheng, Jian

    2017-01-05

    Metal objects implanted in the bodies of patients usually generate severe streaking artifacts in reconstructed images of X-ray computed tomography, which degrade the image quality and affect the diagnosis of disease. Therefore, it is essential to reduce these artifacts to meet the clinical demands. In this work, we propose a Gaussian diffusion sinogram inpainting metal artifact reduction algorithm based on prior images to reduce these artifacts for fan-beam computed tomography reconstruction. In this algorithm, prior information that originated from a tissue-classified prior image is used for the inpainting of metal-corrupted projections, and it is incorporated into a Gaussian diffusion function. The prior knowledge is particularly designed to locate the diffusion position and improve the sparsity of the subtraction sinogram, which is obtained by subtracting the prior sinogram of the metal regions from the original sinogram. The sinogram inpainting algorithm is implemented through an approach of diffusing prior energy and is then solved by gradient descent. The performance of the proposed metal artifact reduction algorithm is compared with two conventional metal artifact reduction algorithms, namely the interpolation metal artifact reduction algorithm and normalized metal artifact reduction algorithm. The experimental datasets used included both simulated and clinical datasets. By evaluating the results subjectively, the proposed metal artifact reduction algorithm causes fewer secondary artifacts than the two conventional metal artifact reduction algorithms, which lead to severe secondary artifacts resulting from impertinent interpolation and normalization. Additionally, the objective evaluation shows the proposed approach has the smallest normalized mean absolute deviation and the highest signal-to-noise ratio, indicating that the proposed method has produced the image with the best quality. No matter for the simulated datasets or the clinical datasets, the proposed algorithm has reduced the metal artifacts apparently.

  19. Comparison of DWI and 18F-FDG PET/CT for assessing preoperative N-staging in gastric cancer: evidence from a meta-analysis

    PubMed Central

    Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo

    2017-01-01

    The diagnostic values of diffusion weighted imaging (DWI) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73–0.85), 0.69 (0.61–0.77), and 0.81 (0.77–0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39–0.64), 0.88 (0.61–0.97), and 0.66 (0.62–0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18F-FDG PET/CT had limited utility for preoperative N-staging. PMID:29137440

  20. Simultaneous (68)Ga-DOTA-TOC PET/MRI with gadoxetate disodium in patients with neuroendocrine tumor.

    PubMed

    Hope, Thomas A; Pampaloni, Miguel Hernandez; Nakakura, Eric; VanBrocklin, Henry; Slater, James; Jivan, Salma; Aparici, Carina Mari; Yee, Judy; Bergsland, Emily

    2015-08-01

    To evaluate a simultaneous PET/MRI approach to imaging patients with neuroendocrine tumor using a combination of (68)Ga-DOTA-TOC as a PET contrast agent and gadoxetate disodium as a hepatobiliary MRI contrast agent. Ten patients with neuroendocrine tumor with known or suspected hepatic disease were imaged using a (68)Ga-DOTA-TOC PET/CT immediately followed by a 3.0T time-of-flight PET/MRI, using a combined whole body and liver specific imaging. The presence of lesions and DOTA-TOC avidity were assessed on CT, PET from PET/CT, diffusion weighted imaging, hepatobiliary phase imaging (HBP), and PET from PET/MRI. Maximum standardized uptake values (SUVmax) in hepatic lesions and nodal metastases were compared between PET/CT and PET/MRI, as were detection rates using each imaging approach. A total of 101 hepatic lesions were identified, 47 of which were DOTA-TOC avid and able to be individually measured on both PET/CT and PET/MRI. HBP imaging had a higher sensitivity for detection of hepatic lesions compared to CT or PET (99% vs. 46% and 64%, respectively; p values <0.001). There was a strong correlation between SUVmax of liver lesions obtained with PET/CT compared to PET/MR imaging (Pearson's correlation = 0.91). For nodal disease, CT had a higher sensitivity compared to whole body MRI (p = 0.015), although PET acquired from PET/MRI detected slightly more lesions compared to PET from PET/CT. A simultaneous PET/MRI using both (68)Ga-DOTA-TOC and gadoxetate disodium was successful in whole body staging of patients with neuroendocrine tumor. HBP imaging had an increased detection rate for hepatic metastases.

  1. Serum metabolites associate with CT findings following TBI.

    PubMed

    Dickens, Alex Mountfort; Posti, Jussi P; Takala, Riikka Sk; Ala-Seppälä, Henna Maria; Mattila, Ismo; Coles, Jonathan Coles; Frantzén, Janek; Hutchinson, Peter John; Katila, Ari J; Kyllönen, Anna; Maanpää, Henna-Riikka; Newcombe, Virginia; Outtrim, Joanne; Tallus, Jussi; Carpenter, Keri; Menon, David; Hyotylainen, Tuulia; Tenovuo, Olli; Oresic, Matej

    2018-06-27

    There is a need to rapidly detect patients with traumatic brain injury (TBI) who require head computed tomography (CT). Given the energy crisis in the brain following TBI, we hypothesized that serum metabolomics would be a useful tool for developing a set of biomarkers to determine the need for CT and to distinguish between different types of injuries observed. Logistic regression models using metabolite data from the discovery cohort (n=144, Turku, Finland) were used to distinguish between patients with traumatic intracranial findings and negative findings on head CT. The resultant models were then tested in the validation cohort (n=66, Cambridge, UK). The levels of glial fibrillary acidic protein and ubiquitin C-terminal hydrolase-L1 were also quantified in the serum from the same patients. Despite there being significant differences in the protein biomarkers in patients with TBI, the model that determined the need for a CT scan validated poorly (AUC=0.64: Cambridge patients). However, using a combination of six metabolites (two amino acids, three sugar derivatives and one ketoacid) it was possible to discriminate patients with intracranial abnormalities on CT and patients with a normal CT (AUC=0.77 in Turku patients and AUC=0.73 in Cambridge patients). Furthermore, a combination of three metabolites could distinguish between diffuse brain injuries and mass lesions (AUC=0.87 in Turku patients and AUC=0.68 in Cambridge patients). This study identifies a set of validated serum polar metabolites, which associate with the need for a CT scan. Additionally, serum metabolites can also predict the nature of the brain injury. These metabolite markers may prevent unnecessary CT scans, thus reducing the cost of diagnostics and radiation load.

  2. Dynamic volumetric computed tomographic assessment of the young paediatric airway: Initial experience of rapid, non-invasive, four-dimensional technique.

    PubMed

    Tan, Judith Zhi-Yie; Crossett, Marcus; Ditchfield, Michael

    2013-04-01

    The aim of this study was to evaluate the dynamic volumetric CT in the assessment of the paediatric airway. Ethics board approval was obtained for this retrospective review. Eight infants (median age 6 months, range 3 weeks to 1 year, 50% female) at a tertiary paediatric centre with complex clinical respiratory presentation underwent volumetric CT assessment of their airways. The entire lungs were examined over 1-2 respiratory cycles. In four patients, intravenous contrast was administered to assess for vascular airway compression. The patients were not intubated. CT findings were correlated with bronchography and bronchoscopy, where available. Two patients had diffuse tracheobronchomalacia associated with chronic lung disease. One patient demonstrated focal severe cervical tracheomalacia. One patient had a double aortic arch causing fixed narrowing with superimposed malacia of the distal trachea. Four patients had normal airways; one with chronic lung disease, one demonstrating air trapping. CT findings were concordant with bronchography (one case) and bronchoscopy (four cases) in all but one (CT negative, bronchoscopy positive) but did not alter patient management. The assessment of the paediatric airway, and in particular for tracheobronchomalacia, is difficult. Assessment with bronchography, bronchoscopy, helical CT and MR have issues with reliability, intubation, intratracheal/bronchial contrast administration and ionising radiation. Volumetric CT assesses the entire central airway in children at much lower radiation dose compared with previous dynamic CT imaging. This non-invasive, rapid assessment obviates the need for patient cooperation and enables evaluation of extratracheal intrathoracic structures. Volumetric CT enables four-dimensional assessment for paediatric tracheobronchomalacia without intubation or patient cooperation and at low radiation dose. © 2012 The Authors. Journal of Medical Imaging and Radiation Oncology © 2012 The Royal Australian and New Zealand College of Radiologists.

  3. Cystic pancreatic neoplasms evaluation by CT and magnetic resonance cholangiopancreatography.

    PubMed

    Sahani, Dushyant; Prasad, Srinivasa; Saini, Sanjay; Mueller, Peter

    2002-10-01

    CT provides limited assistance in the differentiation between serous and mucinous neoplasms. Because of the variability in the radiographic appearance of serous cystadenomas and overlap in CT characteristics with mucinous neoplasms, most serous neoplasms still require ancillary testing such as biopsy to reach a definitive diagnosis. MRCP is useful in differentiating benign and malignant mucinous tumors including IPMT of the pancreas. The presence of mural nodules is suggestive of malignancy; however, the absence of mural nodules does not indicate that the tumor is benign. A maximum main pancreatic duct diameter of greater than 15 mm and diffuse dilatation of the main pancreatic duct are suggestive of malignancy in main duct-type tumors. Among branch duct-type tumors, malignant tumors tend to be larger than benign tumors; however, this finding is variable. The presence of main pancreatic duct dilatation may be helpful in determining malignancy of branch duct-type tumors.

  4. Brain dead or not? CT angiogram yielding false-negative result on brain death confirmation.

    PubMed

    Johnston, Robyn; Kaliaperumal, Chandrasekaran; Wyse, Gerald; Kaar, George

    2013-01-08

    We describe a case of severe traumatic brain injury with multiple facial and skull fractures where CT angiogram (CTA) failed to yield a definite result of brain death as an ancillary test. A 28-year-old man was admitted following a road traffic accident with a Glasgow Coma Score (GCS) of 3/15 and fixed pupils. CT brain revealed uncal herniation and diffuse cerebral oedema with associated multiple facial and skull fractures. 72 h later, his clinical condition remained the same with high intracranial pressure refractory to medical management. Clinical confirmation on brain death was not feasible owing to facial injuries. A CTA, performed to determine brain perfusion, yielded a 'false-negative' result. Skull fractures have possibly led to venous prominence in the cortical and deep venous drainage system. This point needs to be borne in mind while considering CTA as an ancillary test to confirm brain death.

  5. Brain dead or not? CT angiogram yielding false-negative result on brain death confirmation

    PubMed Central

    Johnston, Robyn; Kaliaperumal, Chandrasekaran; Wyse, Gerald; Kaar, George

    2013-01-01

    We describe a case of severe traumatic brain injury with multiple facial and skull fractures where CT angiogram (CTA) failed to yield a definite result of brain death as an ancillary test. A 28-year-old man was admitted following a road traffic accident with a Glasgow Coma Score (GCS) of 3/15 and fixed pupils. CT brain revealed uncal herniation and diffuse cerebral oedema with associated multiple facial and skull fractures. 72 h later, his clinical condition remained the same with high intracranial pressure refractory to medical management. Clinical confirmation on brain death was not feasible owing to facial injuries. A CTA, performed to determine brain perfusion, yielded a ‘false-negative’ result. Skull fractures have possibly led to venous prominence in the cortical and deep venous drainage system. This point needs to be borne in mind while considering CTA as an ancillary test to confirm brain death. PMID:23302550

  6. Comparison of whole body magnetic resonance imaging (WBMRI) to whole body computed tomography (WBCT) or 18F-fluorodeoxyglucose positron emission tomography/CT (18F-FDG PET/CT) in patients with myeloma: Systematic review of diagnostic performance.

    PubMed

    Gariani, Joanna; Westerland, Olwen; Natas, Sarah; Verma, Hema; Cook, Gary; Goh, Vicky

    2018-04-01

    To undertake a systematic review to determine the diagnostic performance of whole body MRI (WBMRI) including diffusion weighted sequences (DWI) compared to whole body computed tomography (WBCT) or 18 F-fluorodeoxyglucose positron emission tomography/CT ( 18 F-FDG PET/CT) in patients with myeloma. Two researchers searched the primary literature independently for WBMRI studies of myeloma. Data were extracted focusing on the diagnostic ability of WBMRI versus WBCT and 18 F-FDG PET/CT. Meta-analysis was intended. 6 of 2857 articles were eligible that included 147 patients, published from 2008 to 2016. Studies were heterogeneous including both newly diagnosed & relapsed patients. All were single centre studies. Four of the six studies (66.7%) accrued prospectively and 5/6 (83.3%, 3 prospective) included WBMRI and 18 F-FDG PET/CT. Three of seven (42.9%) included DWI. The lack of an independent reference standard for individual lesions was noted in 5/6 (83.3%) studies. Studies reported that WBMRI detected more lesions than 18 F-FDG PET/CT (sensitivity 68-100% versus 47-100%) but was less specific (specificity 37-83% versus 62-85.7%). No paper assessed impact on management. Studies were heterogeneous, the majority lacking an independent reference standard. Future prospective trials should address these limitations and assess the impact of WBMRI on management. Copyright © 2018. Published by Elsevier B.V.

  7. Antibacterial activity, surface roughness, flexural strength, and solubility of conventional luting cements containing chlorhexidine diacetate/cetrimide mixtures.

    PubMed

    Korkmaz, Fatih Mehmet; Tüzüner, Tamer; Baygin, Ozgul; Buruk, Celal Kurtulus; Durkan, Rukiye; Bagis, Bora

    2013-08-01

    The failure of fixed dental restorations is commonly associated with caries. The use of conventional luting cements containing antibacterial agents may overcome this problem. The purpose of this study was to evaluate the antibacterial activity (ABA), surface roughness (Ra), flexural strength (FS), and solubility (SL) patterns of the conventional dental luting cements zinc phosphate (ZP), zinc polycarboxylate (PC), and glass ionomer (GIC) after the addition of 5% chlorhexidine diacetate/cetrimide (CHX+CT). Antibacterial agents with a total concentration of 5% (2.5% CHX+2.5% CT) were added to antibacterial agent-free conventional luting cement powders (ZPC, PCC, and GICC) and designated as experimental groups (ZPE, PCE, and GICE). ABA against Streptococcus mutans (SM) and Lactobacillus casei (LB) was examined by using the agar diffusion test method. Ra, FS, and SL values were obtained after storage in distilled water at 37°C for 24 hours. The Kruskal-Wallis and Mann Whitney U with Bonferroni correction tests were used to test for agar diffusion (α=.05) and 2-way ANOVA and Fisher Least Significant Difference (LSD) test were used to measure Ra, FS, and SL (α=.05). The control groups exhibited limited ABA. With the exception of PCE>PCC on day 1 for SM, all experimental groups showed significantly greater and longer-lasting protection against SM and LB bacteria for up to 180 days than their controls (P<.05). Ra values decreased (ZPC>ZPE; P>.05, PCC>PCE; P<.05) except that GICE>GICC (P>.05) when compared with their individual controls. Control groups exhibited higher FS values than did the experimental groups (ZPC>ZPE; P<.05, PCC>PCE; P<.05, GICC>GICE; P>.05). The experimental groups exhibited higher solubilities than did their controls in the ZPC (P>.05) and GICC groups (P<.05) but were lower in PCC group (P<.05). Incorporating a 5% CHX+CT mixture into conventional dental luting cements and altering their Ra, FS, and SL values may provide greater antibacterial protection against SM and LB. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  8. Correlation of the CT Compatible Stereotaxic Craniotomy with MRI Scans of the Patients for Removing Cranial Lesions Located Eloquent Areas and Deep Sites of Brain.

    PubMed

    Gulsen, Salih

    2015-03-15

    The first goal in neurosurgery is to protect neural function as long as it is possible. Moreover, while protecting the neural function, a neurosurgeon should extract the maximum amount of tumoral tissue from the tumour region of the brain. So neurosurgery and technological advancement go hand in hand to realize this goal. Using of CT compatible stereotaxy for removing a cranial tumour is to be commended as a cornerstone of these technological advancements. Following CT compatible stereotaxic system applications in neurosurgery, different techniques have taken place in neurosurgical practice. These techniques are magnetic resonance imaging (MRI), MRI compatible stereotaxis, frameless stereotaxy, volumetric stereotaxy, functional MRI, diffusion tensor (DT) imaging techniques (tractography of the white matter), intraoperative MRI and neuronavigation systems. However, to use all of this equipment having these technologies would be impossible because of economic reasons. However, when we correlated this technique with MRI scans of the patients with CT compatible stereotaxy scans, it is possible to provide gross total resection and protect and improve patients' neural functions.

  9. Thin-Section Computed Tomography Manifestations During Convalescence and Long-Term Follow-Up of Patients with Severe Acute Respiratory Syndrome (SARS).

    PubMed

    Wu, Xiaohua; Dong, Dawei; Ma, Daqing

    2016-08-08

    BACKGROUND SARS is not only an acute disease, but also leads to long-term impaired lung diffusing capacity in some survivors. However, there is a paucity of data regarding long-term CT findings in survivors after SARS. The aim of this study was to assess the changes in lung function and lung thin-section computed tomography (CT) features in patients recovering from severe acute respiratory syndrome (SARS), especially the dynamic changes in ground-glass opacity (GGO). MATERIAL AND METHODS Clinical and radiological data from 11 patients with SARS were collected. The serial follow-up thin-section CTs were evaluated at 3, 6, and 84 months after SARS presentation. The distribution and predominant thin-section CT findings of lesions were evaluated. RESULTS The extent of the lesions on the CT scans of the 11 patients decreased at 6 and 84 months compared to 3 months. The number of segments involved on 84-month follow-up CTs was less than those at 6 months (P<0.05). The predominant thin-section CT manifestation at 84 months (intralobular and interlobular septal thickening) was different than that at 6 months, at which GGO was predominant. CONCLUSIONS During convalescence after SARS, GGO and intralobular and interlobular septal thickening were the main thin-section CT manifestation. Intralobular and interlobular septal thickening predominated over GGO at 84 months.

  10. 18F-Fluorodeoxyglucose Positron Emission Tomography/CT Scanning in Diagnosing Vascular Prosthetic Graft Infection

    PubMed Central

    Saleem, Ben R.; Pol, Robert A.; Slart, Riemer H. J. A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2014-01-01

    Vascular prosthetic graft infection (VPGI) is a severe complication after vascular surgery. CT-scan is considered the diagnostic tool of choice in advanced VPGI. The incidence of a false-negative result using CT is relatively high, especially in the presence of low-grade infections. 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) scanning has been suggested as an alternative for the diagnosis and assessment of infectious processes. Hybrid 18F-FDG PET/CT has established the role of 18F-FDG PET for the assessment of suspected VPGI, providing accurate anatomic localization of the site of infection. However, there are no clear guidelines for the interpretation of the uptake patterns of 18F-FDG as clinical tool for VPGI. Based on the available literature it is suggested that a linear, diffuse, and homogeneous uptake should not be regarded as an infection whereas focal or heterogeneous uptake with a projection over the vessel on CT is highly suggestive of infection. Nevertheless, 18F-FDG PET and 18F-FDG PET/CT can play an important role in the detection of VPGI and monitoring response to treatment. However an accurate uptake and pattern recognition is warranted and cut-off uptake values and patterns need to be standardized before considering the technique to be the new standard. PMID:25210712

  11. Association between matrix metalloproteinase 2 (MMP2) promoter polymorphisms and the susceptibility to non-Hodgkin's lymphoma in Egyptians.

    PubMed

    Gouda, Heba Mahmoud; Khorshied, Mervat Mamdooh; El Sissy, Maha Hamdi; Shaheen, Iman Abdel Mohsen; Mohsen, Mohsen Mokhtar Abdel

    2014-08-01

    Matrix metalloproteinases (MMPs) are zinc-dependent endopeptidases capable of extracellular matrix degradation. MMP2 is the key molecule that control invasion, tumor growth, and metastasis, and has been associated with poor prognosis in several tumors. Several epidemiological studies have focused on the associations between MMP2 promoter polymorphisms and cancer susceptibility; however, little is known about their role in hematological malignancies. The present study aimed to investigate the association of MMP2 -735C/T and -1306C/T promoter polymorphisms with B-NHL susceptibility and their clinicopathological characteristics. The study included 100 B-NHL patients and 100 healthy controls. Genotyping of MMP2 -735C/T and MMP2 -1306C/T was done by polymerase chain reaction restricted fragment length polymorphism (PCR-RFLP) technique. MMP2 -735C/T heteromutant genotype (CT) was detected in 23 % of patients, and the homomutant genotype (TT) was detected in 7 % of patients. The polymorphic allele, T allele, was associated with susceptibility to B-NHL (OR = 2.8:95 %CI = 1.48-5.28). For MMP2 -1306C/T, the frequencies of the polymorphic variants were 5 % for the heteromutant genotype (CT) and 3 % for the homomutant genotype (TT). The polymorphic allele, T allele, conferred almost fourfold increased risk of B-NHL (OR = 3.8, 95 %CI = 1.05-13.9), and the risk elevated to be almost eight folds when confined to diffuse large B-cell lymphoma (DLBCL) (OR = 7.9, 95 %CI = 1.67-32.27). MMP2 -735C/T polymorphic genotypes were correlated with advanced clinical stages of the disease (stages III and IV). In conclusion, the study revealed that the variant alleles of MMP2 -735C/T and MMP2 -1306C/T can be considered as molecular risk factors for B-NHL among Egyptians.

  12. Lifetime Occupational Exposure to Dusts, Gases and Fumes Is Associated with Bronchitis Symptoms and Higher Diffusion Capacity in COPD Patients

    PubMed Central

    Rodríguez, Esther; Ferrer, Jaume; Zock, Jan-Paul; Serra, Ignasi; Antó, Josep M.; de Batlle, Jordi; Kromhout, Hans; Vermeulen, Roel; Donaire-González, David; Benet, Marta; Balcells, Eva; Monsó, Eduard; Gayete, Angel; Garcia-Aymerich, Judith

    2014-01-01

    Background Occupational exposure to dusts, gases and fumes has been associated with reduced FEV1 and sputum production in COPD patients. The effect of occupational exposure on other characteristics of COPD, especially those reflecting emphysema, has not been studied in these patients. Methods We studied 338 patients hospitalized for a first exacerbation of COPD in 9 Spanish hospitals, obtaining full occupational history in a face-to-face interview; job codes were linked to a job exposure matrix for semi-quantitative estimation of exposure to mineral/biological dust, and gases/fumes for each job held. Patients underwent spirometry, diffusing capacity testing and analysis of gases in stable conditions. Quality of life, dyspnea and chronic bronchitis symptoms were determined with a questionnaire interview. A high- resolution CT scan was available in 133 patients. Results 94% of the patients included were men, with a mean age of 68(8.5) years and a mean FEV1% predicted 52 (16). High exposure to gases or fumes was associated with chronic bronchitis, and exposure to mineral dust and gases/fumes was associated with higher scores for symptom perception in the St. George’s questionnaire. No occupational agent was associated with a lower FEV1. High exposure to all occupational agents was associated with better lung diffusion capacity, in long-term quitters. In the subgroup with CT data, patients with emphysema had 18% lower DLCO compared to those without emphysema. Conclusions In our cohort of COPD patients, high exposure to gases or fumes was associated with chronic bronchitis, and high exposure to all occupational agents was consistently associated with better diffusion capacity in long-term quitters. PMID:24516659

  13. Accurate, meshless methods for magnetohydrodynamics

    NASA Astrophysics Data System (ADS)

    Hopkins, Philip F.; Raives, Matthias J.

    2016-01-01

    Recently, we explored new meshless finite-volume Lagrangian methods for hydrodynamics: the `meshless finite mass' (MFM) and `meshless finite volume' (MFV) methods; these capture advantages of both smoothed particle hydrodynamics (SPH) and adaptive mesh refinement (AMR) schemes. We extend these to include ideal magnetohydrodynamics (MHD). The MHD equations are second-order consistent and conservative. We augment these with a divergence-cleaning scheme, which maintains nabla \\cdot B≈ 0. We implement these in the code GIZMO, together with state-of-the-art SPH MHD. We consider a large test suite, and show that on all problems the new methods are competitive with AMR using constrained transport (CT) to ensure nabla \\cdot B=0. They correctly capture the growth/structure of the magnetorotational instability, MHD turbulence, and launching of magnetic jets, in some cases converging more rapidly than state-of-the-art AMR. Compared to SPH, the MFM/MFV methods exhibit convergence at fixed neighbour number, sharp shock-capturing, and dramatically reduced noise, divergence errors, and diffusion. Still, `modern' SPH can handle most test problems, at the cost of larger kernels and `by hand' adjustment of artificial diffusion. Compared to non-moving meshes, the new methods exhibit enhanced `grid noise' but reduced advection errors and diffusion, easily include self-gravity, and feature velocity-independent errors and superior angular momentum conservation. They converge more slowly on some problems (smooth, slow-moving flows), but more rapidly on others (involving advection/rotation). In all cases, we show divergence control beyond the Powell 8-wave approach is necessary, or all methods can converge to unphysical answers even at high resolution.

  14. Diffuse large B-cell lymphoma solely involving bilateral adrenal glands and stomach: report of an extremely rare case with review of the literature.

    PubMed

    Wakabayashi, Mutsumi; Sekiguchi, Yasunobu; Shimada, Asami; Ichikawa, Kunimoto; Sugimoto, Keiji; Tomita, Shigeki; Izumi, Hiroshi; Nakamura, Noriko; Sawada, Tomohiro; Ohta, Yasunori; Komatsu, Norio; Noguchi, Masaaki

    2014-01-01

    A 60-year-old man complained of nausea, vomiting, decreased appetite, and a feeling of abdominal fullness in August 2013. Based on biopsy findings from an upper gastrointestinal endoscopy examination, a diagnosis of non-Hodgkin's lymphoma (NHL), diffuse large B-cell lymphoma (DLBCL), non-GC type, was made. F18-fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) revealed abnormal accumulations solely in the gastric wall (SUVmax = 14.5), the left adrenal gland (SUVmax = 14.3), and the right adrenal gland (SUVmax = 8.5). The clinical stage (Ann Arbor) was IVA, the serum LDH level was within the reference range, and the International Prognostic Index (IPI) was low-intermediate. The serum soluble IL-2 receptor level was within the reference range, and there was no evidence of HIV, EB virus, or autoimmune disease. After the completion of 4 cycles of R-CHOP (rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone) and 2 parallel cycles of prophylactic intrathecal (I.T.), an upper gastrointestinal endoscopy and a FDG-PET/CT examination showed complete remission (CR). The patient received 8 cycles of ritsuximab therapy, 6 cycles of CHOP, and 3 cycles of I.T. The patient has maintained a CR for about 14 months. A literature search revealed that malignant lymphoma with involvement confined to the adrenal gland and gastrointestinal tract is exceedingly rare, and only 3 cases of malignant lymphoma have been reported, with involvement of the stomach in 2 cases and the duodenum in 1 case. All of the cases were diagnosed as DLBCL. The case described herein represents the third case with involvement of the stomach.

  15. Melorheostosis in the upper extremity.

    PubMed

    Yildirim, Cengiz; Ozyürek, Selahattin; Ciçek, Engin Ilker; Kuskucu, Mesih

    2009-04-01

    Melorheostosis is a rare mesodermal disease affecting the skeleton and adjacent soft tissues. Often it is incidentally detected on radiographs. In the standard radiology and orthopedics literature, melorheostosis is described as a "flowing hyperostosis, resembling dripping candle wax as an incidental radiographic finding." A 22-year-old man presented with a 2-year history of right-hand pain. Radiologic evaluation of the hand showed massive sclerotic changes in the first and second metacarpal and phalangeal bones on the right side. Further radiographic evaluation of the right upper extremity revealed the same sclerotic changes in the right scapula, humerus, radius, and scaphoid. Computed tomography (CT) scans showed a high attenuation undulating cortical hyperostosis with a "dripping candle wax appearance" involving the radial and/or dorsal aspects of humerus, radius, scaphoid, and first and second ray bones of the hand. Radionuclide triphasic bone scintigraphy showed diffuse homogenous radiotracer uptake within the entire right upper extremity involving the scapula, humerus, radius, scaphoid, and first and second metacarpals and phalangeal bones of the hand. The patient was followed conservatively, and 1-year follow-up revealed no change in the clinical, laboratory, or radiological findings. The diagnosis of melorheostosis was made on the basis of the characteristic distribution, location, and combined radiographic, CT, and radionuclide imaging features of the abnormalities. Conservative treatment was recommended for the patient. After 26 months of follow-up, despite the persistence of the radiologic findings, the patient is currently well, with no painful symptoms unless he performs forceful exercise.

  16. Diffuse Reflectance Spectroscopy for Total Carbon Analysis of Hawaiian Soils

    NASA Astrophysics Data System (ADS)

    McDowell, M. L.; Bruland, G. L.; Deenik, J. L.; Grunwald, S.; Uchida, R.

    2010-12-01

    Accurate assessment of total carbon (Ct) content is important for fertility and nutrient management of soils, as well as for carbon sequestration studies. The non-destructive analysis of soils by diffuse reflectance spectroscopy (DRS) is a potential supplement or alternative to the traditional time-consuming and costly combustion method of Ct analysis, especially in spatial or temporal studies where sample numbers are large. We investigate the use of the visible to near-infrared (VNIR) and mid-infrared (MIR) spectra of soils coupled with chemometric analysis to determine their Ct content. Our specific focus is on Hawaiian soils of agricultural importance. Though this technique has been introduced to the soil community, it has yet to be fully tested and used in practical applications for all soil types, and this is especially true for Hawaii. In short, DRS characterizes and differentiates materials based on the variation of the light reflected by a material at certain wavelengths. This spectrum is dependent on the material’s composition, structure, and physical state. Multivariate chemometric analysis unravels the information in a set of spectra that can help predict a property such as Ct. This study benefits from the remarkably diverse soils of Hawaii. Our sample set includes 216 soil samples from 145 pedons from the main Hawaiian Islands archived at the National Soil Survey Center in Lincoln, NE, along with more than 50 newly-collected samples from Kauai, Oahu, Molokai, and Maui. In total, over 90 series from 10 of the 12 soil orders are represented. The Ct values of these samples range from < 1% - 55%. We anticipate that the diverse nature of our sample set will ensure a model with applicability to a wide variety of soils, both in Hawaii and globally. We have measured the VNIR and MIR spectra of these samples and obtained their Ct values by dry combustion. Our initial analyses are conducted using only samples obtained from the Lincoln archive. In this preliminary case, we use Partial Least Squares (PLS) regression with cross validation to develop a prediction model for soils of unknown carbon content given only their spectral signature. We find R2 values of greater than 0.93 for the MIR spectra and 0.87 for the VNIR spectra, indicating a strong ability to correlate a soil’s spectrum with its Ct content. We build on these encouraging results by continuing chemometric analyses using the full data set, different data subsets, separate model calibration and validation groups, combined VNIR and MIR spectra, and exploring different data pretreatment options and variations to the PLS parameters.

  17. Low-dose computed tomography in assessment of pulmonary abnormalities in children with febrile neutropenia suffering from malignant diseases.

    PubMed

    Zaleska-Dorobisz, Urszula; Olchowy, Cyprian; Łasecki, Mateusz; Sokołowska-Dąbek, Dąbrówka; Pawluś, Aleksander; Frączkiewicz, Jowita; Gorczyńska, Ewa

    2017-07-01

    Management of febrile neutropenia in pediatric patients is challenging. Chest X-ray and CT scan help to identify infective foci; however, exposure to radiation is a risk factor for development of secondary cancer. For this reason, attention is paid to reducing radiation exposure. The aim of the study was to define the role of LDCT examination in the early detection of pulmonary lesions in children during oncology or autoimmune treatment complicated by neutropenia-related fever. Additionally, we focused on the possibility to optimize image quality in low-dose protocols. The study included 138 pediatric patients (mean age 8.08 years) with fever of 38.2°C or higher with an absolute neutrophil count of 10 mm with or without surrounding GGO or cavitations was sensitive at 77% and specific at 65% for fungal infection insert after neutrophil count: < 500/pL who underwent chest X-ray and LDCT in the maximal interval of 24 h. CT findings were compared with initial and final diagnosis as well as with clinical information. LDCT detected pulmonary abnormalities in 116 patients (84.06%) showing ground-glass opacities (GGO) (n = 79), nodules (n = 60) and air-space consolidations (n = 58). Radiologists correctly diagnosed infective lesions in 94 out of 116 patients (81.03%). The presence of random or pleural-based nodules. Diagnosis of pyogenic infection based on the presence of air-space consolidation, pleural effusion, GGO or centrilobular nodules showed a sensitivity of 78% and specificity of 67%, whereas patchy or diffuse GGO, interstitial thickening and/or air-space consolidation showed a high sensitivity of 81% and specificity of 68% for Pneumocystis jirovecii pneumonia. LDCT is an excellent modality in the diagnostic algorithm in patients with febrile neutropenia. It allows early detection and detailed characterization of pulmonary abnormalities. Using contrast, unenhanced CT examinations can further reduce radiation dose and diminish the number of complications without a negative influence on the diagnostic process.

  18. Modeling bioluminescent photon transport in tissue based on Radiosity-diffusion model

    NASA Astrophysics Data System (ADS)

    Sun, Li; Wang, Pu; Tian, Jie; Zhang, Bo; Han, Dong; Yang, Xin

    2010-03-01

    Bioluminescence tomography (BLT) is one of the most important non-invasive optical molecular imaging modalities. The model for the bioluminescent photon propagation plays a significant role in the bioluminescence tomography study. Due to the high computational efficiency, diffusion approximation (DA) is generally applied in the bioluminescence tomography. But the diffusion equation is valid only in highly scattering and weakly absorbing regions and fails in non-scattering or low-scattering tissues, such as a cyst in the breast, the cerebrospinal fluid (CSF) layer of the brain and synovial fluid layer in the joints. A hybrid Radiosity-diffusion model is proposed for dealing with the non-scattering regions within diffusing domains in this paper. This hybrid method incorporates a priori information of the geometry of non-scattering regions, which can be acquired by magnetic resonance imaging (MRI) or x-ray computed tomography (CT). Then the model is implemented using a finite element method (FEM) to ensure the high computational efficiency. Finally, we demonstrate that the method is comparable with Mont Carlo (MC) method which is regarded as a 'gold standard' for photon transportation simulation.

  19. Distinguishing the Effects of Local Point Sources from Those Caused by Upstream Nonpoint Source (NPS) Inputs: Refinement of a Watershed Development Index for New England

    EPA Science Inventory

    Using EMAP data from the NE Wadeable Stream Survey and state datasets (CT, ME), assessment tools were developed to predict diffuse NPS effects from watershed development and distinguish these from local impacts (point sources, contaminated sediments). Classification schemes were...

  20. 64Cu DOTA-Trastuzumab PET/CT in Studying Patients With Gastric Cancer

    ClinicalTrials.gov

    2017-12-11

    Adenocarcinoma of the Gastroesophageal Junction; Diffuse Adenocarcinoma of the Stomach; Intestinal Adenocarcinoma of the Stomach; Mixed Adenocarcinoma of the Stomach; Recurrent Gastric Cancer; Stage IA Gastric Cancer; Stage IB Gastric Cancer; Stage IIA Gastric Cancer; Stage IIB Gastric Cancer; Stage IIIA Gastric Cancer; Stage IIIB Gastric Cancer; Stage IIIC Gastric Cancer; Stage IV Gastric Cancer

  1. TU-AB-BRA-07: Distortion-Free 3D Diffusion MRI On An MRI-Guided Radiotherapy System for Longitudinal Tumor Response Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Y; Yang, Y; Rangwala, N

    Purpose: To develop a reliable, 3D distortion-free diffusion MRI technique for longitudinal tumor response assessment and MRI-guided adaptive radiotherapy(RT). Methods: A diffusion prepared 3D turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) sequence in a commercially available diffusion phantom, and one head-and-neck and one brain cancer patient on an MRI-guided RT system (ViewRay). In phantom study, the geometric fidelity was quantified as the ratio between the left-right (RL) and anterior-posterior (AP) dimension. Ten slices were measured on DP-TSE, DW-ssEPI and standard TSE images where the later was used as the geometricmore » reference. ADC accuracy was verified at both 0°C (reference ADC available) and room temperature with a range of diffusivity between 0.35 and 2.0*10{sup −3}mm{sup 2}/s. The ADC reproducibility was assessed based on 8 room-temperature measurements on 6 different days. In the pilot single-slice in-vivo study, CT images were used as the geometric reference, and ADC maps from both diffusion sequences were compared. Results: Distortion and susceptive-related artifact were severe in DW-ssEPI, with significantly lower RL/AP ratio (0.9579±0.0163) than DP-TSE (0.9990±0.0031) and TSE (0.9995±0.0031). ADCs from the two diffusion sequences both matched well with the vendor-provided values at 0°C; however DW-ssEPI fails to provide accurate ADC for high diffusivity vials at room temperature due to high noise level (10 times higher than DP-TSE). The DP-TSE sequence had excellent ADC reproducibility with <4% ADC variation among 8 separate measurements. In patient study, DP-TSE exhibited substantially improved geometric reliability. ROI analysis in ADC maps generated from DP-TSE and DW-ssEPI showed <5% difference where high b-value images were excluded from the latter approach due to excessive noise level. Conclusion: A diffusion MRI sequence with excellent geometric fidelity, accurate and highly reproducible ADC measurements was proposed for longitudinal tumor response assessment using an MRI-guided RT system. Yu Gao acknowledges research support from ViewRay.« less

  2. Acute Effects of Modafinil on Brain Resting State Networks in Young Healthy Subjects

    PubMed Central

    Pieramico, Valentina; Ferretti, Antonio; Macchia, Antonella; Tommasi, Marco; Saggino, Aristide; Ciavardelli, Domenico; Manna, Antonietta; Navarra, Riccardo; Cieri, Filippo; Stuppia, Liborio; Tartaro, Armando; Sensi, Stefano L.

    2013-01-01

    Background There is growing debate on the use of drugs that promote cognitive enhancement. Amphetamine-like drugs have been employed as cognitive enhancers, but they show important side effects and induce addiction. In this study, we investigated the use of modafinil which appears to have less side effects compared to other amphetamine-like drugs. We analyzed effects on cognitive performances and brain resting state network activity of 26 healthy young subjects. Methodology A single dose (100 mg) of modafinil was administered in a double-blind and placebo-controlled study. Both groups were tested for neuropsychological performances with the Raven’s Advanced Progressive Matrices II set (APM) before and three hours after administration of drug or placebo. Resting state functional magnetic resonance (rs-FMRI) was also used, before and after three hours, to investigate changes in the activity of resting state brain networks. Diffusion Tensor Imaging (DTI) was employed to evaluate differences in structural connectivity between the two groups. Protocol ID: Modrest_2011; NCT01684306; http://clinicaltrials.gov/ct2/show/NCT01684306. Principal Findings Results indicate that a single dose of modafinil improves cognitive performance as assessed by APM. Rs-fMRI showed that the drug produces a statistically significant increased activation of Frontal Parietal Control (FPC; p<0.04) and Dorsal Attention (DAN; p<0.04) networks. No modifications in structural connectivity were observed. Conclusions and Significance Overall, our findings support the notion that modafinil has cognitive enhancing properties and provide functional connectivity data to support these effects. Trial Registration ClinicalTrials.gov NCT01684306 http://clinicaltrials.gov/ct2/show/NCT01684306. PMID:23935959

  3. Acute effects of modafinil on brain resting state networks in young healthy subjects.

    PubMed

    Esposito, Roberto; Cilli, Franco; Pieramico, Valentina; Ferretti, Antonio; Macchia, Antonella; Tommasi, Marco; Saggino, Aristide; Ciavardelli, Domenico; Manna, Antonietta; Navarra, Riccardo; Cieri, Filippo; Stuppia, Liborio; Tartaro, Armando; Sensi, Stefano L

    2013-01-01

    There is growing debate on the use of drugs that promote cognitive enhancement. Amphetamine-like drugs have been employed as cognitive enhancers, but they show important side effects and induce addiction. In this study, we investigated the use of modafinil which appears to have less side effects compared to other amphetamine-like drugs. We analyzed effects on cognitive performances and brain resting state network activity of 26 healthy young subjects. A single dose (100 mg) of modafinil was administered in a double-blind and placebo-controlled study. Both groups were tested for neuropsychological performances with the Raven's Advanced Progressive Matrices II set (APM) before and three hours after administration of drug or placebo. Resting state functional magnetic resonance (rs-FMRI) was also used, before and after three hours, to investigate changes in the activity of resting state brain networks. Diffusion Tensor Imaging (DTI) was employed to evaluate differences in structural connectivity between the two groups. Protocol ID: Modrest_2011; NCT01684306; http://clinicaltrials.gov/ct2/show/NCT01684306. Results indicate that a single dose of modafinil improves cognitive performance as assessed by APM. Rs-fMRI showed that the drug produces a statistically significant increased activation of Frontal Parietal Control (FPC; p<0.04) and Dorsal Attention (DAN; p<0.04) networks. No modifications in structural connectivity were observed. Overall, our findings support the notion that modafinil has cognitive enhancing properties and provide functional connectivity data to support these effects. ClinicalTrials.gov NCT01684306 http://clinicaltrials.gov/ct2/show/NCT01684306.

  4. Inter- and Intraobserver Agreement of 18F-FDG PET/CT Image Interpretation in Patients Referred for Assessment of Cardiac Sarcoidosis.

    PubMed

    Ohira, Hiroshi; Ardle, Brian Mc; deKemp, Robert A; Nery, Pablo; Juneau, Daniel; Renaud, Jennifer M; Klein, Ran; Clarkin, Owen; MacDonald, Karen; Leung, Eugene; Nair, Girish; Beanlands, Rob; Birnie, David

    2017-08-01

    Recent studies have reported the usefulness of 18 F-FDG PET in aiding with the diagnosis and management of patients with cardiac sarcoidosis (CS). However, image interpretation of 18 F-FDG PET for CS is sometimes challenging. We sought to investigate the inter- and intraobserver agreement and explore factors that led to important discrepancies between readers. Methods: We studied consecutive patients with no significant coronary artery disease who were referred for assessment of CS. Two experienced readers masked to clinical information, imaging reports, independently reviewed 18 F-FDG PET/CT images. 18 F-FDG PET/CT images were interpreted according to a predefined standard operating procedure, with cardiac 18 F-FDG uptake patterns categorized into 5 patterns: none, focal, focal on diffuse, diffuse, and isolated lateral wall or basal uptake. Overall image assessment was classified as either consistent with active CS or not. Results: One hundred scans were included from 71 patients. Of these, 46 underwent 18 F-FDG PET/CT with a no-restriction diet (no-restriction group), and 54 underwent 18 F-FDG PET/CT with a low-carbohydrate, high-fat and protein-permitted diet (low-carb group). There was agreement of the interpretation category in 74 of 100 scans. The κ-value of agreement among all 5 categories was 0.64, indicating moderate agreement. For overall clinical interpretation, there was agreement in 93 of 100 scans (κ = 0.85). When scans were divided into the preparation groups, there was a trend toward higher agreement in the low-carb group versus the no-restriction group (80% vs. 67%, P = 0.08). Regarding the overall clinical interpretation, there was also a trend toward greater agreement in the low-carb group versus the no-restriction group (96% vs. 89%, P = 0.08). Conclusion : The interobserver agreement of cardiac 18 F-FDG uptake image patterns was moderate. However, agreement was better regarding overall interpretation of CS. Detailed prescan dietary preparation seemed to improve interobserver agreement. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  5. Role of New Functional MRI Techniques in the Diagnosis, Staging, and Followup of Gynecological Cancer: Comparison with PET-CT

    PubMed Central

    Alvarez Moreno, Elena; Jimenez de la Peña, Mar; Cano Alonso, Raquel

    2012-01-01

    Recent developments in diagnostic imaging techniques have magnified the role and potential of both MRI and PET-CT in female pelvic imaging. This article reviews the techniques and clinical applications of new functional MRI (fMRI) including diffusion-weighted MRI (DWI), dynamic contrast-enhanced (DCE)-MRI, comparing with PET-CT. These new emerging provide not only anatomic but also functional imaging, allowing detection of small volumes of active tumor at diagnosis and early disease relapse, which may not result in detectable morphological changes at conventional imaging. This information is useful in distinguishing between recurrent/residual tumor and post-treatment changes and assessing treatment response, with a clear impact on patient management. Both PET-CT and now fMRI have proved to be very valuable tools for evaluation of gynecologic tumors. Most papers try to compare these techniques, but in our experience both are complementary in management of these patients. Meanwhile PET-CT is superior in diagnosis of ganglionar disease; fMRI presents higher accuracy in local preoperative staging. Both techniques can be used as biomarkers of tumor response and present high accuracy in diagnosis of local recurrence and peritoneal dissemination, with complementary roles depending on histological type, anatomic location and tumoral volume. PMID:22315683

  6. Increased Intracranial Pressure during Hemodialysis in a Patient with Anoxic Brain Injury.

    PubMed

    Lund, Anton; Damholt, Mette B; Strange, Ditte G; Kelsen, Jesper; Møller-Sørensen, Hasse; Møller, Kirsten

    2017-01-01

    Dialysis disequilibrium syndrome (DDS) is a serious neurological complication of hemodialysis, and patients with acute brain injury are at increased risk. We report a case of DDS leading to intracranial hypertension in a patient with anoxic brain injury and discuss the subsequent dialysis strategy. A 13-year-old girl was admitted after prolonged resuscitation from cardiac arrest. Computed tomography (CT) revealed an inferior vena cava aneurysm and multiple pulmonary emboli as the likely cause. An intracranial pressure (ICP) monitor was inserted, and, on day 3, continuous renal replacement therapy (CRRT) was initiated due to acute kidney injury, during which the patient developed severe intracranial hypertension. CT of the brain showed diffuse cerebral edema. CRRT was discontinued, sedation was increased, and hypertonic saline was administered, upon which ICP normalized. Due to persistent hyperkalemia and overhydration, ultrafiltration and intermittent hemodialysis were performed separately on day 4 with a small dialyzer, low blood and dialysate flow, and high dialysate sodium content. During subsequent treatments, isolated ultrafiltration was well tolerated, whereas hemodialysis was associated with increased ICP necessitating frequent pauses or early cessation of dialysis. In patients at risk of DDS, hemodialysis should be performed with utmost care and continuous monitoring of ICP should be considered.

  7. Contrast-enhanced ultrasound in the diagnosis of nodules in liver cirrhosis

    PubMed Central

    Kim, Tae Kyoung; Jang, Hyun-Jung

    2014-01-01

    Contrast-enhanced ultrasound (CEUS) using microbubble contrast agents are useful for the diagnosis of the nodules in liver cirrhosis. CEUS can be used as a problem-solving method for indeterminate nodules on computed tomography (CT) or magnetic resonance imaging (MRI) or as an initial diagnostic test for small newly detected liver nodules. CEUS has unique advantages over CT and MRI including no renal excretion of contrast, real-time imaging capability, and purely intravascular contrast. Hepatocellular carcinoma (HCC) is characterized by arterial-phase hypervascularity and later washout (negative enhancement). Benign nodules such as regenerative nodules or dysplastic nodules are usually isoechoic or slightly hypoechoic in the arterial phase and isoechoic in the late phase. However, there are occasional HCC lesions with atypical enhancement including hypovascular HCC and hypervascular HCC without washout. Cholangiocarcinomas are infrequently detected during HCC surveillance and mostly show rim-like or diffuse hypervascularity followed by rapid washout. Hemangiomas are often found at HCC surveillance and are easily diagnosed by CEUS. CEUS can be effectively used in the diagnostic work-up of small nodules detected at HCC surveillance. CEUS is also useful to differentiate malignant and benign venous thrombosis and to guide and monitor the local ablation therapy for HCC. PMID:24707142

  8. Contrast-enhanced ultrasound in the diagnosis of nodules in liver cirrhosis.

    PubMed

    Kim, Tae Kyoung; Jang, Hyun-Jung

    2014-04-07

    Contrast-enhanced ultrasound (CEUS) using microbubble contrast agents are useful for the diagnosis of the nodules in liver cirrhosis. CEUS can be used as a problem-solving method for indeterminate nodules on computed tomography (CT) or magnetic resonance imaging (MRI) or as an initial diagnostic test for small newly detected liver nodules. CEUS has unique advantages over CT and MRI including no renal excretion of contrast, real-time imaging capability, and purely intravascular contrast. Hepatocellular carcinoma (HCC) is characterized by arterial-phase hypervascularity and later washout (negative enhancement). Benign nodules such as regenerative nodules or dysplastic nodules are usually isoechoic or slightly hypoechoic in the arterial phase and isoechoic in the late phase. However, there are occasional HCC lesions with atypical enhancement including hypovascular HCC and hypervascular HCC without washout. Cholangiocarcinomas are infrequently detected during HCC surveillance and mostly show rim-like or diffuse hypervascularity followed by rapid washout. Hemangiomas are often found at HCC surveillance and are easily diagnosed by CEUS. CEUS can be effectively used in the diagnostic work-up of small nodules detected at HCC surveillance. CEUS is also useful to differentiate malignant and benign venous thrombosis and to guide and monitor the local ablation therapy for HCC.

  9. Why the dark matter of galaxies is clumps of micro­ brown­dwarfs and not Cold Dark Matter

    NASA Astrophysics Data System (ADS)

    Gibson, Carl H.

    Observations of quasar microlensing by Schild 1996 show the baryonic dark matter BDM of galaxies is micro-brown-dwarfs, primordial hydrogen-helium planets formed at the plasma to gas transition 10^13 seconds, in trillion-planet clumps termed proto-globular-star-clusters PGCs. Large photon-viscosity {nu} of the plasma permits supercluster-mass gravitational fragmentation at 10^12 seconds when the horizon scale L_H = ct is matched by the Schwarz viscous scale L_SV of Gibson 1996. Voids begin expansion at sonic speeds c/ 3^1/2, where c is light speed and t is time, explaining 10^25 meter size regions observed to be devoid of all matter, either BDM or non-baryonic NBDM. Most of the NBDM is weakly-collisional, strongly-diffusive, neutrino-like particles. If cold NBDM (CDM) is assumed, it must soon become warm and diffuse because it is weakly-collisional. It cannot clump and its clumps cannot clump. CDM is ruled out with 99% confidence by local-group satellite observations of Kroupa et al. 2010. The satellites are clusters of PGCs. PGCs are recaptured by the Galaxy on an accretion disk as they freeze and diffuse from its core to form its BDM halo. Stars form by viscous mergers of primordial gas planets within PGCs. Stars die by overeating mBDs, making the first chemicals, oceans and life at 2-8 Myr.

  10. [Fever, atrial fibrillation, and angina pectoris in a 58-year-old man].

    PubMed

    Groebner, M; Südhoff, T; Doering, M; Kirmayer, M; Nitsch, T; Prügl, L; Römer, W; Wolf, H; Tacke, J; Massoudy, P; Nüsse, T; Elsner, D

    2014-05-01

    Primary cardiac lymphoma (PCL) respresents a very rare type of cardiac tumour. This report illustrates a case of PCL in an immunocompetent 58-year-old man presenting with atrial fibrillation and febrile syndrome. Comprehensive imaging [computer tomography (CT), cardiac magnetic resonance imaging (cMRI), 3-dimensional transesophageal echocardiography (3D-TEE)] identified a large right atrial tumour, leading to pericardial effusion. Isolated cardiac involvement was confirmed by positron emission tomography (PET)-CT. A diffuse large B-cell lymphoma (DLBCL) was diagnosed based on the results of a TEE-guided biopsy. A normalized PET scan (PETAL study) indicated complete remission following R-CHOP 14 immunochemotherapy. Thus, an interdisciplinary and multimodal approach avoided unnecessary cardiac surgery.

  11. Peripheral neurolymphomatosis with tracheal asphyxia: a case report and literature review.

    PubMed

    Liu, Zuofeng; Jiang, Tao; Hou, Ni; Jia, Yongqian

    2015-08-23

    Neurolymphomatosis (NL) is an extremely rare disease and tracheal asphyxia due to NL has not been previously reported. A 54-year-old Chinese woman with a history of diffuse large B-cell lymphoma in her first complete remission developed peripheral neuropathy and tracheal asphyxia. Neurolymphomatosis involving the right brachial plexus and the right vagus nerve was demonstrated by PET/CT, but not by MRI. She underwent urgent tracheotomy and impact chemotherapy using rituximab combined with high dose methotrexate and involved field radiotherapy. She achieved a second complete remission. PET/CT plays valuable role in differentiating NL from other neuropathies in patients with lymphoma. Complete remission can be achieved in NL due to large B-cell lymphoma.

  12. Recent advances in imaging cancer of the kidney and urinary tract.

    PubMed

    Hilton, Susan; Jones, Lisa P

    2014-10-01

    Modern radiologic imaging is an aid to treatment planning for localized renal cancer, enabling characterization of mass lesions. For patients who present with advanced renal cancer, new imaging techniques enable a functional assessment of treatment response not possible using anatomic measurements alone. Multidetector CT urography permits simultaneous assessment of the kidneys and urinary tract for patients with unexplained hematuria. Both CT and MRI play a significant role in staging and follow up of patients treated for urothelial cancer. Newer imaging methods such as diffusion-weighted MRI have shown promising results for improving accuracy of staging and follow up of urothelial cancer. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Radiological and Pathological Correlation in Anti-MDA5 Antibody-positive Interstitial Lung Disease: Rapidly Progressive Perilobular Opacities and Diffuse Alveolar Damage.

    PubMed

    Chino, Haruka; Sekine, Akimasa; Baba, Tomohisa; Iwasawa, Tae; Okudela, Koji; Takemura, Tamiko; Itoh, Harumi; Sato, Shinji; Suzuki, Yasuo; Ogura, Takashi

    2016-01-01

    We herein present the first case of rapidly progressive interstitial lung disease (RP-ILD) with anti-melanoma differentiation-associated protein 5 (MDA5) antibody evaluated by surgical lung biopsy (SLB). High-resolution CT scan revealed perilobular opacities, which rapidly became thicker and formed consolidation, resulting in remarkable loss of lung volume. Specimens taken from SLB revealed membranous organization with alveolar occlusion, dilation of alveolar ducts, and sacs with collapsed alveoli, which are typical features of diffuse alveolar damage (DAD). Rapidly progressive perilobular opacities may be characteristic of RP-ILD with anti-MDA5 antibody and DAD.

  14. Transport of neutral solute across articular cartilage: the role of zonal diffusivities.

    PubMed

    Arbabi, V; Pouran, B; Weinans, H; Zadpoor, A A

    2015-07-01

    Transport of solutes through diffusion is an important metabolic mechanism for the avascular cartilage tissue. Three types of interconnected physical phenomena, namely mechanical, electrical, and chemical, are all involved in the physics of transport in cartilage. In this study, we use a carefully designed experimental-computational setup to separate the effects of mechanical and chemical factors from those of electrical charges. Axial diffusion of a neutral solute Iodixanol into cartilage was monitored using calibrated microcomputed tomography micro-CT images for up to 48 hr. A biphasic-solute computational model was fitted to the experimental data to determine the diffusion coefficients of cartilage. Cartilage was modeled either using one single diffusion coefficient (single-zone model) or using three diffusion coefficients corresponding to superficial, middle, and deep cartilage zones (multizone model). It was observed that the single-zone model cannot capture the entire concentration-time curve and under-predicts the near-equilibrium concentration values, whereas the multizone model could very well match the experimental data. The diffusion coefficient of the superficial zone was found to be at least one order of magnitude larger than that of the middle zone. Since neutral solutes were used, glycosaminoglycan (GAG) content cannot be the primary reason behind such large differences between the diffusion coefficients of the different cartilage zones. It is therefore concluded that other features of the different cartilage zones such as water content and the organization (orientation) of collagen fibers may be enough to cause large differences in diffusion coefficients through the cartilage thickness.

  15. Diagnostic Accuracy of Ultrasound, Contrast-enhanced CT, and Conventional MRI for Differentiating Leiomyoma From Leiomyosarcoma.

    PubMed

    Gaetke-Udager, Kara; McLean, Karen; Sciallis, Andrew P; Alves, Timothy; Maturen, Katherine E; Mervak, Benjamin M; Moore, Andreea G; Wasnik, Ashish P; Erba, Jake; Davenport, Matthew S

    2016-10-01

    This study aimed to determine whether uterine leiomyoma can be distinguished from uterine leiomyosarcoma on ultrasound (US), computed tomography (CT), and/or magnetic resonance imaging (MRI) without diffusion-weighted imaging. Institutional review board approval was obtained and informed consent was waived for this Health Insurance Portability and Accountability Act-compliant retrospective case-control diagnostic accuracy study. All subjects with resected uterine leiomyosarcoma diagnosed over a 17-year period (1998-2014) at a single institution for whom pre-resection US (n = 10), CT (n = 11), or MRI (n = 7) was available were matched by tumor size and imaging modality with 28 subjects with resected uterine leiomyoma. Six blinded radiologists (three attendings, three residents) assigned 5-point Likert scores for the following features: (1) margins, (2) necrosis, (3) hemorrhage, (4) vascularity, (5) calcifications, (6) heterogeneity, and (7) likelihood of malignancy (primary end point). Mean suspicion scores were calculated and receiver operating characteristic curves were generated. The ability of individual morphologic features to predict malignancy was assessed with logistic regression. Mean suspicion scores were 2.5 ± 1.2 (attendings) and 2.4 ± 1.3 (residents) for leiomyoma, and 2.7 ± 1.3 (attendings) and 2.7 ± 1.4 (residents) for leiomyosarcoma. The areas under the receiver operating characteristic curves (range: 0.330-0.685) were not significantly different from chance, either overall (P = .36-.88) or by any modality (P = .28-.96), for any reader. Reader experience had no effect on diagnostic accuracy. No morphologic parameter was significantly predictive of malignancy (P = .10-.97). Uterine leiomyoma cannot be differentiated accurately from leiomyosarcoma on US, CT, or MRI without diffusion-weighted imaging. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. Computed Tomography Findings of Pigmented Villonodular Synovitis in a Dog.

    PubMed

    Dempsey, Lara M; Maddox, Thomas W; Meiring, Thelma; Wustefeld-Janssens, Brandan; Comerford, Eithne J

    2018-06-04

    Pigmented villonodular synovitis (PVNS) is a rare benign and usually monoarticular neoplastic lesion arising from the synovium, bursae and tendon sheaths in humans, horses and dogs. Categorization for PVNS in humans includes localized and diffuse forms of PVNS and tenosynovial giant cell tumour (TGCT), although histologically they are the same. The localized form is characterized by discrete nodular lesions, the diffuse form is often intra-articular, infiltrative, affecting the entire synovium with more aggressive behaviour and TGCT occurs along tendon sheaths. Computed tomography (CT) of PVNS is well described in humans but not documented in the veterinary literature. Pigmented villonodular synovitis is not a straightforward diagnosis and CT is useful to further characterize radiographic findings. A representative open surgical biopsy of the synovium is essential to obtaining the diagnosis and ruling out malignancy. Currently, there are no guidelines for the diagnosis of PVNS in dogs or long-term follow-up of these cases. This case report describes the presentation, diagnostic findings, treatment and long-term outcome of a 4-year-old male Labrador Retriever with confirmed PVNS. Clinical outcome was considered fair with the dog's lameness and symptoms remaining stable with medical management 3 years following the initial diagnosis. Schattauer GmbH Stuttgart.

  17. Diffuse skull base/cervical fusion syndromes in two siblings with spondylocostal dysostosis syndrome: analysis via three dimensional computed tomography scanning.

    PubMed

    Al Kaissi, Ali; Ben Chehida, Farid; Ben Ghachem, Maher; Klaushofer, Klaus; Grill, Franz

    2008-06-01

    A study on a pair of male sibs to reach for the etiological understanding of unusual skull base/spine maldevelopment. Previously, radiographs alone were used to formulate this diagnosis. Here, three-dimensional computed tomography (3D CT) studies further clarified the typical diagnostic findings associated with spondylocostal dysostosis (SCD). Interestingly, patients with SCD are at increased risk for diffuse skull base/cervical fusion syndromes and can result in severe neurologic deficits associated with any degree of trauma. Classically SCD is defined as a skeletal dysplasia with clinical and radiologic manifestations, consisting of short neck and trunk, nonprogressive scoliosis and abnormalities of vertebral segmentation and of the ribs. Radiograms have been adopted as the only modality for the classification and prognostication of patients with SCD. Detailed clinical and radiographic examinations were undertaken with emphasis on the significance of the 3D CT scanning. We observed extensive fusion of the clivus with the cervical/entire spine, resulting in a remarkable solid, immobile, and fixed bony ankylosis of extremely serious outcome. Patients with spondylcostal dysostosis are predisposed to develop extensive skull-base-cervical spine fusion. The latter might lead to the development of a solid, immobile, and fixed bony ankylosis. In children/adults trivial injuries and/or high-energy trauma can lead to serious intracranial and spinal cord injury. Comprehensive orthopedic and neurosurgeons management must follow the recognition of these anomalies. To the best of our knowledge, no previous CT studies of the spine have been published in patients with SCD.

  18. CT of chronic infiltrative lung disease: Prevalence of mediastinal lymphadenopathy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Niimi, Hiroshi; Kang, Eun-Young; Kwong, S.

    1996-03-01

    Our goal was to determine the prevalence of mediastinal lymph node enlargement at CT in patients with diffuse infiltrative lung disease. The study was retrospective and included 175 consecutive patients with diffuse infiltrative lung diseases. Diagnoses included idiopathic pulmonary fibrosis (IPF) (n = 61), usual interstitial pneumonia associated with collagen vascular disease (CVD) (n = 20), idiopathic bronchiolitis obliterans organizing pneumonia (BOOP) (n = 22), extrinsic allergic alveolitis (EAA) (n = 17), and sarcoidosis (n = 55). Fifty-eight age-matched patients with CT of the chest performed for unrelated conditions served as controls. The presence, number, and sites of enlarged nodesmore » (short axis {ge}10 mm in diameter) were recorded. Enlarged mediastinal nodes were present in 118 of 175 patients (67%) with infiltrative lung disease and 3 of 58 controls (5%) (p < 0.001). The prevalence of enlarged nodes was 84% (46 of 55) in sarcoidosis, 67% (41 of 61) in IPF, 70% (14 of 20) in CVD, 53% (9 of 17) in EAA, and 36% (8 of 22) in BOOP. The mean number of enlarged nodes was higher in sarcoidosis (mean 3.2) than in the other infiltrative diseases (mean 1.2) (p < 0.001). Enlarged nodes were most commonly present in station 10R, followed by 7, 4R, and 5. Patients with infiltrative lung disease frequently have enlarged mediastinal lymph nodes. However, in diseases other than sarcoid, usually only one or two nodes are enlarged and their maximal short axis diameter is <15 mm. 11 refs., 2 figs., 1 tab.« less

  19. Radiotherapy dose–response analysis for diffuse large B-cell lymphoma with a complete response to chemotherapy

    PubMed Central

    2012-01-01

    Objective To examine the efficacy of different radiation doses after achievement of a complete response to chemotherapy in diffuse large B-cell lymphoma (DLBCL). Methods Patients with stage I-IV DLBCL treated from 1995–2009 at Duke Cancer Institute who achieved a complete response to chemotherapy were reviewed. In-field control, event-free survival, and overall survival were calculated using the Kaplan-Meier method. Dose response was evaluated by grouping treated sites by delivered radiation dose. Results 105 patients were treated with RT to 214 disease sites. Chemotherapy (median 6 cycles) was R-CHOP (65%), CHOP (26%), R-CNOP (2%), or other (7%). Post-chemotherapy imaging was PET/CT (88%), gallium with CT (1%), or CT only (11%). The median RT dose was 30 Gy (range, 12–40 Gy). The median radiation dose was higher for patients with stage I-II disease compared with patients with stage III-IV disease (30 versus 24.5 Gy, p < 0.001). Five-year in-field control, event-free survival, and overall survival for all patients was 94% (95% CI: 89-99%), 84% (95% CI: 77-92%), and 91% (95% CI: 85-97%), respectively. Six patients developed an in-field recurrence at 10 sites, without a clear dose response. In-field failure was higher at sites ≥ 10 cm (14% versus 4%, p = 0.06). Conclusion In-field control was excellent with a combined modality approach when a complete response was achieved after chemotherapy without a clear radiation dose response. PMID:22720801

  20. Technetium-99m-HMPAO SPECT in the evaluation of patients with a remote history of traumatic brain injury: a comparison with x-ray computed tomography.

    PubMed

    Gray, B G; Ichise, M; Chung, D G; Kirsh, J C; Franks, W

    1992-01-01

    The functional imaging modality has potential for demonstrating parenchymal abnormalities not detectable by traditional morphological imaging. Fifty-three patients with a remote history of traumatic brain injury (TBI) were studied with SPECT using 99mTc-hexamethylpropyleneamineoxime (HMPAO) and x-ray computed tomography (CT). Overall, 42 patients (80%) showed regional cerebral blood flow (rCBF) deficits by HMPAO SPECT, whereas 29 patients (55%) showed morphological abnormalities by CT. Out of 20 patients with minor head injury, 12 patients (60%) showed rCBF deficits and 5 patients (25%) showed CT abnormalities. Of 33 patients with major head injury, 30 patients (90%) showed rCBF deficits and 24 patients (72%) showed CT abnormalities. Thus, HMPAO SPECT was more sensitive than CT in detecting abnormalities in patients with a history of TBI, particularly in the minor head injury group. In the major head injury group, three patients showed localized cortical atrophy by CT and normal rCBF by HMPAO SPECT. In the evaluation of TBI patients, HMPAO SPECT is a useful technique to demonstrate regional brain dysfunction in the presence of morphological integrity as assessed by CT.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poulou, Loukia S., E-mail: ploukia@hotmail.com; Tsangaridou, Iris; Filippoussis, Petros

    Bronchiolitis obliterans organizing pneumonia (BOOP) is a nonneoplastic, noninfectious lung disease with a diverse spectrum of imaging abnormalities and nonspecific symptoms diagnosed by open lung biopsy, transbroncial biopsy, and/or video-assisted thoracoscopy. The objective of this study was to retrospectively assess the role of percutaneous computed tomography (CT)-guided biopsy in early diagnosis of the disorder. Fourteen BOOP cases diagnosed by CT-guided biopsy were analyzed in terms of imaging abnormalities and complication rate. All had previously undergone a nondiagnostic procedure (bronchoscopy, transbronchial biopsy, bronchoalveolar lavage) to exclude infection or lung cancer. The most common imaging abnormalities in descending order were bilateral consolidationsmore » (5/14), unilateral tumor-like lesions (5/14), unilateral consolidations (3/14), and diffuse reticular pattern (1/14). Coexistent abnormalities (pleural effusions, nodules, ground-glass opacities) were observed in five patients. The complication rate was 4 of 14 (28.6%), including 2 cases of subclinical pneumothorax and 1 case of minor hemoptysis and local lung injury. None required intervention. We conclude that transthoracic CT-guided biopsy may be used in the diagnosis of BOOP in selected patients with mild complications. For the focal consolidation nodule/mass imaging pattern, CT-guided biopsy may prove to be a reasonable alternative to more invasive procedures.« less

  2. Tuberculous spondylodiscitis in a patient with a sickle-cell disease: CT findings.

    PubMed

    Krupniewski, Leszek; Palczewski, Piotr; Gołębiowski, Marek; Kosińska-Kaczyńska, Katarzyna

    2012-01-01

    Although sickle-cell anemia (SCA) is common in black Americans, Sub-Saharan Africa and in the Mediterranean area, the disease is rare in the temperate climate zone. The manifestations of the disease are related mainly to the production of abnormal hemoglobin that leads to organ ischemia and increased susceptibility to infection caused by functional asplenia. The authors present CT findings in a 39-year-old black woman diagnosed due to abdominal pain, lymphadenopathy and fever. CT of the thorax and abdomen demonstrated changes in the liver, spleen, and skeletal system suggestive of SCA complicated with spondylodiscitis in the thoracic spine. Hepatomegaly and small calcified spleen are typical findings in older homozygotic patients with SCA. The lesions in the skeleton may be related either to intramedullary hematopoiesis or osteonecrosis and osteomyelitis. In the latter case, diffuse osteosclerosis and H-shaped vertebrae are most typical. Tuberculous spondylodiscitis is characterized by the location in the thoracic region, preferential involvement of anterior elements, relative sparing of intervertebral discs, and cold abscesses.

  3. First MRI application of an active breathing coordinator

    NASA Astrophysics Data System (ADS)

    Kaza, E.; Symonds-Tayler, R.; Collins, D. J.; McDonald, F.; McNair, H. A.; Scurr, E.; Koh, D.-M.; Leach, M. O.

    2015-02-01

    A commercial active breathing coordinator (ABC) device, employed to hold respiration at a specific level for a predefined duration, was successfully adapted for magnetic resonance imaging (MRI) use for the first time. Potential effects of the necessary modifications were assessed and taken into account. Automatic MR acquisition during ABC breath holding was achieved. The feasibility of MR-ABC thoracic and abdominal examinations together with the advantages of imaging in repeated ABC-controlled breath holds were demonstrated on healthy volunteers. Five lung cancer patients were imaged under MR-ABC, visually confirming the very good intra-session reproducibility of organ position in images acquired with the same patient positioning as used for computed tomography (CT). Using identical ABC settings, good MR-CT inter-modality registration was achieved. This demonstrates the value of ABC, since application of T1, T2 and diffusion weighted MR sequences provides a wider range of contrast mechanisms and additional diagnostic information compared to CT, thus improving radiotherapy treatment planning and assessment.

  4. First MRI application of an active breathing coordinator.

    PubMed

    Kaza, E; Symonds-Tayler, R; Collins, D J; McDonald, F; McNair, H A; Scurr, E; Koh, D-M; Leach, M O

    2015-02-21

    A commercial active breathing coordinator (ABC) device, employed to hold respiration at a specific level for a predefined duration, was successfully adapted for magnetic resonance imaging (MRI) use for the first time. Potential effects of the necessary modifications were assessed and taken into account. Automatic MR acquisition during ABC breath holding was achieved. The feasibility of MR-ABC thoracic and abdominal examinations together with the advantages of imaging in repeated ABC-controlled breath holds were demonstrated on healthy volunteers. Five lung cancer patients were imaged under MR-ABC, visually confirming the very good intra-session reproducibility of organ position in images acquired with the same patient positioning as used for computed tomography (CT). Using identical ABC settings, good MR-CT inter-modality registration was achieved. This demonstrates the value of ABC, since application of T1, T2 and diffusion weighted MR sequences provides a wider range of contrast mechanisms and additional diagnostic information compared to CT, thus improving radiotherapy treatment planning and assessment.

  5. First MRI application of an active breathing coordinator

    PubMed Central

    Kaza, E; Symonds-Tayler, R; Collins, D J; McDonald, F; McNair, H A; Scurr, E; Koh, D-M; Leach, M O

    2015-01-01

    Abstract A commercial active breathing coordinator (ABC) device, employed to hold respiration at a specific level for a predefined duration, was successfully adapted for magnetic resonance imaging (MRI) use for the first time. Potential effects of the necessary modifications were assessed and taken into account. Automatic MR acquisition during ABC breath holding was achieved. The feasibility of MR-ABC thoracic and abdominal examinations together with the advantages of imaging in repeated ABC-controlled breath holds were demonstrated on healthy volunteers. Five lung cancer patients were imaged under MR-ABC, visually confirming the very good intra-session reproducibility of organ position in images acquired with the same patient positioning as used for computed tomography (CT). Using identical ABC settings, good MR-CT inter-modality registration was achieved. This demonstrates the value of ABC, since application of T1, T2 and diffusion weighted MR sequences provides a wider range of contrast mechanisms and additional diagnostic information compared to CT, thus improving radiotherapy treatment planning and assessment. PMID:25633183

  6. TH-EF-207A-07: An Integrated X-Ray/bioluminescence Tomography System for Radiation Guidance and Tumor Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, J; Udayakumar, T; Wang, Z

    Purpose: CT is not able to differentiate tumors from surrounding soft tissue. This study is to develop a bioluminescence tomography (BLT) system that is integrated onto our previously developed CT guided small animal arc radiation treatment system (iSMAART) to guide radiation, monitor tumor growth and evaluate therapeutic response. Methods: The BLT system employs a CCD camera coupled with a high speed lens, and is aligned orthogonally to the x-ray beam central axis. The two imaging modalities, CT and BLT, are physically registered through geometrical calibration. The CT anatomy provides an accurate contour of animal surface which is used to constructmore » 3D mesh for BLT reconstruction. Bioluminescence projections are captured from multiple angles, once every 45 degree rotation. The diffusion equation based on analytical Kirchhoff approximation is adopted to model the photon propagation in tissues. A discrete cosine transform based reweighted L1-norm regularization (DCT-re-L1) algorithm is used for BLT reconstruction. Experiments are conducted on a mouse orthotopic prostate tumor model (n=12) to evaluate the BLT performance, in terms of its robustness and accuracy in locating and quantifying the bioluminescent tumor cells. Iodinated contrast agent was injected intravenously to delineate the tumor in CT. The tumor location and volume obtained from CT also serve as a benchmark against BLT. Results: With our cutting edge reconstruction algorithm, BLT is able to accurately reconstruct the orthotopic prostate tumors. The tumor center of mass in BLT is within 0.5 mm radial distance of that in CT. The tumor volume in BLT is significantly correlated with that in CT (R2 = 0.81). Conclusion: The BLT can differentiate, localize and quantify tumors. Together with CT, BLT will provide precision radiation guidance and reliable treatment assessment in preclinical cancer research.« less

  7. Cationic Contrast Agent Diffusion Differs Between Cartilage and Meniscus.

    PubMed

    Honkanen, Juuso T J; Turunen, Mikael J; Freedman, Jonathan D; Saarakkala, Simo; Grinstaff, Mark W; Ylärinne, Janne H; Jurvelin, Jukka S; Töyräs, Juha

    2016-10-01

    Contrast enhanced computed tomography (CECT) is a non-destructive imaging technique used for the assessment of composition and structure of articular cartilage and meniscus. Due to structural and compositional differences between these tissues, diffusion and distribution of contrast agents may differ in cartilage and meniscus. The aim of this study is to determine the diffusion kinematics of a novel iodine based cationic contrast agent (CA(2+)) in cartilage and meniscus. Cylindrical cartilage and meniscus samples (d = 6 mm, h ≈ 2 mm) were harvested from healthy bovine knee joints (n = 10), immersed in isotonic cationic contrast agent (20 mgI/mL), and imaged using a micro-CT scanner at 26 time points up to 48 h. Subsequently, normalized X-ray attenuation and contrast agent diffusion flux, as well as water, collagen and proteoglycan (PG) contents in the tissues were determined. The contrast agent distributions within cartilage and meniscus were different. In addition, the normalized attenuation and diffusion flux were higher (p < 0.05) in cartilage. Based on these results, diffusion kinematics vary between cartilage and meniscus. These tissue specific variations can affect the interpretation of CECT images and should be considered when cartilage and meniscus are assessed simultaneously.

  8. Comparison of 68Ga-HBED-CC PSMA-PET/CT and multiparametric MRI for gross tumour volume detection in patients with primary prostate cancer based on slice by slice comparison with histopathology

    PubMed Central

    Zamboglou, Constantinos; Drendel, Vanessa; Jilg, Cordula A.; Rischke, Hans C.; Beck, Teresa I.; Schultze-Seemann, Wolfgang; Krauss, Tobias; Mix, Michael; Schiller, Florian; Wetterauer, Ulrich; Werner, Martin; Langer, Mathias; Bock, Michael; Meyer, Philipp T.; Grosu, Anca L.

    2017-01-01

    Purpose: The exact detection and delineation of the intraprostatic tumour burden is crucial for treatment planning in primary prostate cancer (PCa). We compared 68Ga-HBED-CC-PSMA PET/CT with multiparametric MRI (mpMRI) for diagnosis and tumour delineation in patients with primary PCa based on slice by slice correlation with histopathological reference material. Methodology: Seven patients with histopathologically proven primary PCa underwent 68Ga-HBED-CC-PSMA PET/CT and MRI followed by radical prostatectomy. Resected prostates were scanned by ex-vivo CT in a special localizer and prepared for histopathology. Invasive PCa was delineated on a HE stained histologic tissue slide and matched to ex-vivo CT to obtain gross tumor volume (GTV-)histo. Ex-vivo CT including GTV-histo and MRI data were matched to in-vivo CT(PET). Consensus contours based on MRI (GTV-MRI), PSMA PET (GTV-PET) or the combination of both (GTV-union/-intersection) were created. In each in-vivo CT slice the prostate was separated into 4 equal segments and sensitivity and specificity for PSMA PET and mpMRI were assessed by comparison with histological reference material. Furthermore, the spatial overlap between GTV-histo and GTV-PET/-MRI and the Sørensen-Dice coefficient (DSC) were calculated. In the case of multifocal PCa (4/7 patients), SUV values (PSMA PET) and ADC-values (diffusion weighted MRI) were obtained for each lesion. Results: PSMA PET and mpMRI detected PCa in all patients. GTV-histo was detected in 225 of 340 segments (66.2%). Sensitivity and specificity for GTV-PET, GTV-MRI, GTV-union and GTV-intersection were 75% and 87%, 70% and 82%, 82% and 67%, 55% and 99%, respectively. GTV-histo had on average the highest overlap with GTV-union (57±22%), which was significantly higher than overlap with GTV-MRI (p=0.016) and GTV-PET (p=0.016), respectively. The mean DSC for GTV-union, GTV-PET and GTV-MRI was 0.51 (±0.18), 0.45 (±0.17) and 0.48 (±0.19), respectively. In every patient with multifocal PCa there was one lesion which had both the highest SUV and the lowest ADC-value (mean and max). Conclusion: In a slice by slice analysis with histopathology, 68Ga-HBED-CC-PSMA PET/CT and mpMRI showed high sensitivity and specificity in detection of primary PCa. A combination of both methods performed even better in terms of sensitivity (GTV-union) and specificity (GTV-intersection). A moderate to good spatial overlap with GTV-histo was observed for PSMA PET/CT and mpMRI alone which was significantly improved by GTV-union. Further studies are warranted to analyse the impact of these preliminary findings for diagnostic (multimodal guided TRUS biopsy) and therapeutic (focal therapy) strategies in primary PCa. PMID:28042330

  9. Development of a cylindrical diffusing optical fiber probe for pancreatic cancer therapy

    NASA Astrophysics Data System (ADS)

    Lee, Sangyeob; Park, Gaye; Park, Jihoon; Yu, Sungkon; Ha, Myungjin; Jang, Seulki; Ouh, Chihwan; Jung, Changhyun; Jung, Byungjo

    2017-02-01

    Although the patients with cancer on pancreas or pancreaticobiliary duct have been increased, it is very difficult to detect and to treat the pancreatic cancer because of its low accessibility and obtuseness. The pancreatic cancer has been diagnosed using ultrasonography, blood test, CT, endoscopic retrograde cholangiopancreatography (ERCP), endoscopic ultrasonography (EUS) and etc. Normally, light can be delivered to the target by optical fibers through the ERCP or EUS. Diffusing optical fibers have been developed with various methods. However, many of them have mechanical and biological problems in the use of small-bend-radius apparatus or in tissue area. This study developed a therapeutic cylindrical diffusing optical fiber probe (CDOFP) for ERCP and EUS which has moderate flexibility and solidity to treat the cancer on pancreaticobiliary duct or pancreas. The CDOFP consists of a biocompatible Teflon tube and multimode glass fiber which has diffusing area processed with laser and high refractive index resin. The CDOFP was characterized to investigate the clinical feasibility and other applications of light therapy using diffusing optical fiber. The results presented that the CDOFP may be used in clinic by combining with endoscopic method, such as ERCP or EUS, to treat cancer on pancreas and pancreaticobiliary duct.

  10. Structure and properties of clinical coralline implants measured via 3D imaging and analysis.

    PubMed

    Knackstedt, Mark Alexander; Arns, Christoph H; Senden, Tim J; Gross, Karlis

    2006-05-01

    The development and design of advanced porous materials for biomedical applications requires a thorough understanding of how material structure impacts on mechanical and transport properties. This paper illustrates a 3D imaging and analysis study of two clinically proven coral bone graft samples (Porites and Goniopora). Images are obtained from X-ray micro-computed tomography (micro-CT) at a resolution of 16.8 microm. A visual comparison of the two images shows very different structure; Porites has a homogeneous structure and consistent pore size while Goniopora has a bimodal pore size and a strongly disordered structure. A number of 3D structural characteristics are measured directly on the images including pore volume-to-surface-area, pore and solid size distributions, chord length measurements and tortuosity. Computational results made directly on the digitized tomographic images are presented for the permeability, diffusivity and elastic modulus of the coral samples. The results allow one to quantify differences between the two samples. 3D digital analysis can provide a more thorough assessment of biomaterial structure including the pore wall thickness, local flow, mechanical properties and diffusion pathways. We discuss the implications of these results to the development of optimal scaffold design for tissue ingrowth.

  11. Neuropsychological outcome after traumatic temporal lobe damage.

    PubMed

    Formisano, R; Schmidhuber-Eiler, B; Saltuari, L; Cigany, E; Birbamer, G; Gerstenbrand, F

    1991-01-01

    The most frequent sequelae after severe brain injury include changes in personality traits, disturbances of emotional behaviour and impairment of cognitive functions. In particular, emotional changes and/or verbal and non verbal dysfunctions were found in patients with bilateral or unilateral temporal lobe lesions. The aim of our study is to correlate the localization of the brain damage after severe brain injury, in particular of the temporal lobe, with the cognitive impairment and the emotional and behavioural changes resulting from these lesions. The patients with right temporal lobe lesions showed significantly better scores in verbal intelligence and verbal memory in comparison with patients with left temporal lobe lesions and those with other focal brain lesions or diffuse brain damage. In contradistinction, study of the personality and the emotional changes (MMPI and FAF) failed to demonstrate pathological scores in the 3 groups with different CT lesions, without any significant difference being found between the groups with temporal lesions and those with other focal brain lesions or diffuse brain damage. The severity of the brain injury and the prolongation of the disturbance of consciousness could, in our patients, account for prevalence of congnitive impairment on personality and emotional changes.

  12. Distinct biological subtypes and patterns of genome evolution in lymphoma revealed by circulating tumor DNA.

    PubMed

    Scherer, Florian; Kurtz, David M; Newman, Aaron M; Stehr, Henning; Craig, Alexander F M; Esfahani, Mohammad Shahrokh; Lovejoy, Alexander F; Chabon, Jacob J; Klass, Daniel M; Liu, Chih Long; Zhou, Li; Glover, Cynthia; Visser, Brendan C; Poultsides, George A; Advani, Ranjana H; Maeda, Lauren S; Gupta, Neel K; Levy, Ronald; Ohgami, Robert S; Kunder, Christian A; Diehn, Maximilian; Alizadeh, Ash A

    2016-11-09

    Patients with diffuse large B cell lymphoma (DLBCL) exhibit marked diversity in tumor behavior and outcomes, yet the identification of poor-risk groups remains challenging. In addition, the biology underlying these differences is incompletely understood. We hypothesized that characterization of mutational heterogeneity and genomic evolution using circulating tumor DNA (ctDNA) profiling could reveal molecular determinants of adverse outcomes. To address this hypothesis, we applied cancer personalized profiling by deep sequencing (CAPP-Seq) analysis to tumor biopsies and cell-free DNA samples from 92 lymphoma patients and 24 healthy subjects. At diagnosis, the amount of ctDNA was found to strongly correlate with clinical indices and was independently predictive of patient outcomes. We demonstrate that ctDNA genotyping can classify transcriptionally defined tumor subtypes, including DLBCL cell of origin, directly from plasma. By simultaneously tracking multiple somatic mutations in ctDNA, our approach outperformed immunoglobulin sequencing and radiographic imaging for the detection of minimal residual disease and facilitated noninvasive identification of emergent resistance mutations to targeted therapies. In addition, we identified distinct patterns of clonal evolution distinguishing indolent follicular lymphomas from those that transformed into DLBCL, allowing for potential noninvasive prediction of histological transformation. Collectively, our results demonstrate that ctDNA analysis reveals biological factors that underlie lymphoma clinical outcomes and could facilitate individualized therapy. Copyright © 2016, American Association for the Advancement of Science.

  13. Government health policy and the diffusion of new medical devices.

    PubMed Central

    Hillman, B J

    1986-01-01

    The combination of absent financial incentives, aspects of physicians' clinical training, and the uncertainty surrounding the appropriate application of expensive new medical devices have been the most significant factors in promoting their wasteful diffusion and use. This presentation summarizes the forces that have resulted in regulatory and reimbursement initiatives to make more efficient the acquisition and utilization of new medical devices. The case histories of computed tomography (CT) and magnetic resonance imaging (MRI) serve as a paradigm demonstrating why such initiatives have thus far proved ineffectual. More effective would be to abandon distinctions between inpatient and outpatient reimbursement for using new medical devices and to improve the relationship between reimbursement and technology assessment. PMID:3818311

  14. Lecithin-coated gold nanoflowers (GNFs) for CT scan imaging applications and biochemical parameters; in vitro and in vivo studies.

    PubMed

    Aziz, Farooq; Bano, Khizra; Siddique, Ahmad Hassan; Bajwa, Sadia Zafar; Nazir, Aalia; Munawar, Anam; Shaheen, Ayesha; Saeed, Madiha; Afzal, Muhammad; Iqbal, M Zubair; Wu, Aiguo; Khan, Waheed S

    2018-01-09

    We report a novel strategy for the fabrication of lecithin-coated gold nanoflowers (GNFs) via single-step design for CT imaging application. Field-emission electron microscope confirmed flowers like morphology of the as-synthesized nanostructures. Furthermore, these show absorption peak in near-infrared (NIR) region at λ max 690 nm Different concentrations of GNFs are tested as a contrast agent in CT scans at tube voltage 135 kV and tube current 350 mA. These results are compared with same amount of iodine at same CT scan parameters. The results of in vitro CT scan study show that GNFs have good contrast enhancement properties, whereas in vivo study of rabbits CT scan shows that GNFs enhance the CT image clearly at 135 kV as compared to that of iodine. Cytotoxicity was studied and blood profile show minor increase of white blood cells and haemoglobin, whereas decrease of red blood cells and platelets.

  15. Chest Radiological Findings of Patients With Severe H1N1 Pneumonia Requiring Intensive Care.

    PubMed

    Rohani, Payam; Jude, Cecilia M; Chan, Kelvin; Barot, Nikhil; Kamangar, Nader

    2016-01-01

    A new strain of human influenza A (H1N1) virus originated from Mexico in 2009 and spread to more than 190 countries and territories. The World Health Organization (WHO) declared it a level 6 (highest level) pandemic. In August 2010, WHO announced that the H1N1 2009 influenza virus had moved into the postpandemic period. The WHO also declared that this flu strain is expected to continue to circulate as a seasonal virus "for some years to come." The objective of this study is to describe the chest radiographic and computed tomography (CT) findings of patients with severe H1N1 pneumonia admitted to the intensive care unit (ICU) during the 2009 pandemic. Patients with severe H1N1 pneumonia requiring ICU admission have extensive radiographic and CT abnormalities. Eighteen patients, aged 23 to 62 (mean 41), admitted to the ICU at UCLA-Olive View Medical Center with a primary diagnosis of pandemic H1N1 infection, confirmed either via rapid influenza detection test or by real-time reverse transcriptase polymerase chain reaction assay, formed the study population. All patients had chest x-ray (CXR) within 24 hours of admission and 5 patients had CT examinations. In this retrospective study, images were evaluated for the pattern (ground-glass opacities, consolidation, reticular opacities, and nodular opacities), distribution (unilateral/bilateral, upper/middle/lower lung zone, and central/peripheral/peribronchovascular), and extent (focal/multifocal/diffuse; number of lung zones) of abnormalities. All (100%) patients had abnormal CXR and CT studies. The predominant radiographic findings were ground-glass opacities (16 of 18; 89%), consolidation (16 of 18; 89%), and reticular opacities (6 of 18, 33%). The radiographic abnormalities were bilateral in 17 (94%) patients; involved lower lung distribution in 18 (100%) patients, and mid and lower lung distribution in 16 (89%) patients. Radiographic abnormalities were peribronchovascular in 11 (61%) patients and multifocal in 10 (56%). Sixteen (89%) patients had extensive abnormalities involving 3 or more lung zones. The patients requiring mechanical ventilation had a higher incidence of bilateral, diffuse consolidation in a peribronchovascular distribution on chest radiographs. The predominant CT abnormalities were consolidation (5 of 5; 100%), ground-glass opacities (5 of 5; 100%), and nodular opacities (3 of 5, 60%). The CT findings were peribronchovascular and multifocal in 4 (80%) patients and extensive and bilateral in all (100%) patients. Patients with H1N1 pneumonia admitted to the ICU had bilateral, extensive CXR, and CT abnormalities. Consolidations and ground-glass opacities were the most common imaging findings, predominantly affecting mid and lower lung zones. Imaging abnormalities were peribronchovascular and multifocal in a majority of patients. © The Author(s) 2014.

  16. MIND Demons: Symmetric Diffeomorphic Deformable Registration of MR and CT for Image-Guided Spine Surgery.

    PubMed

    Reaungamornrat, Sureerat; De Silva, Tharindu; Uneri, Ali; Vogt, Sebastian; Kleinszig, Gerhard; Khanna, Akhil J; Wolinsky, Jean-Paul; Prince, Jerry L; Siewerdsen, Jeffrey H

    2016-11-01

    Intraoperative localization of target anatomy and critical structures defined in preoperative MR/CT images can be achieved through the use of multimodality deformable registration. We propose a symmetric diffeomorphic deformable registration algorithm incorporating a modality-independent neighborhood descriptor (MIND) and a robust Huber metric for MR-to-CT registration. The method, called MIND Demons, finds a deformation field between two images by optimizing an energy functional that incorporates both the forward and inverse deformations, smoothness on the integrated velocity fields, a modality-insensitive similarity function suitable to multimodality images, and smoothness on the diffeomorphisms themselves. Direct optimization without relying on the exponential map and stationary velocity field approximation used in conventional diffeomorphic Demons is carried out using a Gauss-Newton method for fast convergence. Registration performance and sensitivity to registration parameters were analyzed in simulation, phantom experiments, and clinical studies emulating application in image-guided spine surgery, and results were compared to mutual information (MI) free-form deformation (FFD), local MI (LMI) FFD, normalized MI (NMI) Demons, and MIND with a diffusion-based registration method (MIND-elastic). The method yielded sub-voxel invertibility (0.008 mm) and nonzero-positive Jacobian determinants. It also showed improved registration accuracy in comparison to the reference methods, with mean target registration error (TRE) of 1.7 mm compared to 11.3, 3.1, 5.6, and 2.4 mm for MI FFD, LMI FFD, NMI Demons, and MIND-elastic methods, respectively. Validation in clinical studies demonstrated realistic deformations with sub-voxel TRE in cases of cervical, thoracic, and lumbar spine.

  17. MIND Demons: Symmetric Diffeomorphic Deformable Registration of MR and CT for Image-Guided Spine Surgery

    PubMed Central

    Reaungamornrat, Sureerat; De Silva, Tharindu; Uneri, Ali; Vogt, Sebastian; Kleinszig, Gerhard; Khanna, Akhil J; Wolinsky, Jean-Paul; Prince, Jerry L.

    2016-01-01

    Intraoperative localization of target anatomy and critical structures defined in preoperative MR/CT images can be achieved through the use of multimodality deformable registration. We propose a symmetric diffeomorphic deformable registration algorithm incorporating a modality-independent neighborhood descriptor (MIND) and a robust Huber metric for MR-to-CT registration. The method, called MIND Demons, finds a deformation field between two images by optimizing an energy functional that incorporates both the forward and inverse deformations, smoothness on the integrated velocity fields, a modality-insensitive similarity function suitable to multimodality images, and smoothness on the diffeomorphisms themselves. Direct optimization without relying on the exponential map and stationary velocity field approximation used in conventional diffeomorphic Demons is carried out using a Gauss-Newton method for fast convergence. Registration performance and sensitivity to registration parameters were analyzed in simulation, phantom experiments, and clinical studies emulating application in image-guided spine surgery, and results were compared to mutual information (MI) free-form deformation (FFD), local MI (LMI) FFD, normalized MI (NMI) Demons, and MIND with a diffusion-based registration method (MIND-elastic). The method yielded sub-voxel invertibility (0.008 mm) and nonzero-positive Jacobian determinants. It also showed improved registration accuracy in comparison to the reference methods, with mean target registration error (TRE) of 1.7 mm compared to 11.3, 3.1, 5.6, and 2.4 mm for MI FFD, LMI FFD, NMI Demons, and MIND-elastic methods, respectively. Validation in clinical studies demonstrated realistic deformations with sub-voxel TRE in cases of cervical, thoracic, and lumbar spine. PMID:27295656

  18. Characteristic CT and MR imaging findings of cerebral paragonimiasis.

    PubMed

    Xia, Yong; Chen, Jing; Ju, Yan; You, Chao

    2016-06-01

    The early diagnosis of cerebral paragonimiasis (CP) is essential for a good prognosis. We seek to provide references for early diagnosis by analyzing the imaging characteristics of cerebral paragonimiasis. Images of 27 patients with CP (22 males and 5 females; median age 20.3 years; range: 4 to 47 years) were retrospectively evaluated. All patients underwent head computed tomography (CT) scans; 22 patients underwent conventional magnetic resonance imaging (MRI) sequences, including contrast-enhanced MRI for 20 patients and diffusion-weighted-imaging (DWI) for 1 patient. The diagnosis was confirmed based on a positive antibody test using enzyme-linked immunosorbent assay (ELISA) for paragonimiasis in the serum. The most common imaging findings of CP were isodense or hypodense lesions combined with extensive hypodense areas of perilesional edema on CT scans and a large mass composed of multiple ring-shaped lesions with surrounding edema on MRI images. The conglomeration of multiple ring-shaped lesions (n=11 patients), "tunnel signs" (n=12 patients) and worm-eaten signs (n=5 patients) were characteristic of most CP images. In 14 patients, contrast-enhanced MRI showed varying degrees of contrast enhancement combined with adjacent meningeal enhancement (n=10). A large mass comprising multiple ring-shaped lesions of different sizes, "tunnel signs" and worm-eaten signs with surrounding edema are the most characteristic features of CP. Extensive invasions of the adjacent meninges and ventricular wall (19 patients), multiple intracerebral lesions, bilateral hemispheric involvement, and lesion migration are other noteworthy imaging characteristics. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. A long-term soil structure observatory for post-compaction soil structure evolution: design and initial soil structure recovery observations

    NASA Astrophysics Data System (ADS)

    Keller, Thomas; Colombi, Tino; Ruiz, Siul; Grahm, Lina; Reiser, René; Rek, Jan; Oberholzer, Hans-Rudolf; Schymanski, Stanislaus; Walter, Achim; Or, Dani

    2016-04-01

    Soil compaction due to agricultural vehicular traffic alters the geometrical arrangement of soil constituents, thereby modifying mechanical properties and pore spaces that affect a range of soil hydro-ecological functions. The ecological and economic costs of soil compaction are dependent on the immediate impact on soil functions during the compaction event, and a function of the recovery time. In contrast to a wealth of soil compaction information, mechanisms and rates of soil structure recovery remain largely unknown. A long-term (>10-yr) soil structure observatory (SSO) was established in 2014 on a loamy soil in Zurich, Switzerland, to quantify rates and mechanisms of structure recovery of compacted arable soil under different post-compaction management treatments. We implemented three initial compaction treatments (using a two-axle agricultural vehicle with 8 Mg wheel load): compaction of the entire plot area (i.e. track-by-track), compaction in wheel tracks, and no compaction. After compaction, we implemented four post-compaction soil management systems: bare soil (BS), permanent grass (PG), crop rotation without mechanical loosening (NT), and crop rotation under conventional tillage (CT). BS and PG provide insights into uninterrupted natural processes of soil structure regeneration under reduced (BS) and normal biological activity (PG). The two cropping systems (NT and CT) enable insights into soil structure recovery under common agricultural practices with minimal (NT) and conventional mechanical soil disturbance (CT). Observations include periodic sampling and measurements of soil physical properties, earthworm abundance, crop measures, electrical resistivity and ground penetrating radar imaging, and continuous monitoring of state variables - soil moisture, temperature, CO2 and O2 concentrations, redox potential and oxygen diffusion rates - for which a network of sensors was installed at various depths (0-1 m). Initial compaction increased soil bulk density to about half a metre, decreased gas and water transport functions (air permeability, gas diffusivity, saturated hydraulic conductivity), and increased mechanical impedance. Water infiltration at the soil surface was initially reduced by three orders of magnitude, but significantly recovered within a year. However, within the soil profile, recovery of transport properties is much smaller. Air permeability tended to recover more than gas diffusivity, suggesting that initial post-compaction recovery is initiated by new macropores (e.g. biopores). Tillage recovered topsoil bulk density but not topsoil transport functions. Compaction changed grass species composition in PG, and significantly reduced grass biomass in PG and crop yields in NT and CT.

  20. Size variation and collapse of emphysema holes at inspiration and expiration CT scan: evaluation with modified length scale method and image co-registration.

    PubMed

    Oh, Sang Young; Lee, Minho; Seo, Joon Beom; Kim, Namkug; Lee, Sang Min; Lee, Jae Seung; Oh, Yeon Mok

    2017-01-01

    A novel approach of size-based emphysema clustering has been developed, and the size variation and collapse of holes in emphysema clusters are evaluated at inspiratory and expiratory computed tomography (CT). Thirty patients were visually evaluated for the size-based emphysema clustering technique and a total of 72 patients were evaluated for analyzing collapse of the emphysema hole in this study. A new approach for the size differentiation of emphysema holes was developed using the length scale, Gaussian low-pass filtering, and iteration approach. Then, the volumetric CT results of the emphysema patients were analyzed using the new method, and deformable registration was carried out between inspiratory and expiratory CT. Blind visual evaluations of EI by two readers had significant correlations with the classification using the size-based emphysema clustering method ( r -values of reader 1: 0.186, 0.890, 0.915, and 0.941; reader 2: 0.540, 0.667, 0.919, and 0.942). The results of collapse of emphysema holes using deformable registration were compared with the pulmonary function test (PFT) parameters using the Pearson's correlation test. The mean extents of low-attenuation area (LAA), E1 (<1.5 mm), E2 (<7 mm), E3 (<15 mm), and E4 (≥15 mm) were 25.9%, 3.0%, 11.4%, 7.6%, and 3.9%, respectively, at the inspiratory CT, and 15.3%, 1.4%, 6.9%, 4.3%, and 2.6%, respectively at the expiratory CT. The extents of LAA, E2, E3, and E4 were found to be significantly correlated with the PFT parameters ( r =-0.53, -0.43, -0.48, and -0.25), with forced expiratory volume in 1 second (FEV 1 ; -0.81, -0.62, -0.75, and -0.40), and with diffusing capacity of the lungs for carbon monoxide (cDLco), respectively. The fraction of emphysema that shifted to the smaller subgroup showed a significant correlation with FEV 1 , cDLco, forced expiratory flow at 25%-75% of forced vital capacity, and residual volume (RV)/total lung capacity ( r =0.56, 0.73, 0.40, and -0.58). A detailed assessment of the size variation and collapse of emphysema holes may be useful for understanding the dynamic collapse of emphysema and its functional relation.

  1. SU-F-P-26: Study of Radiation Dose Evaluation for Organs at Risk Using MRI in Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, G; Guo, Y; Yin, Y

    Purpose: To study the contour and dosimetric feature of organs at risk (OARs) applying magnetic resonance imaging (MRI) images in intensity modulated radiation therapy (IMRT) of nasopharyngeal carcinoma (NPC) compared to computed tomography (CT) images. Methods: 35 NPC patients was selected into this trail. CT simulation with non-contrast and contrast enhanced scan, MRI simulation with non-contrast and contrast enhanced T1, T2 and diffusion weighted imaging were achieved sequentially. And the OARs were contoured on the CT and MRI images after rigid registration respectively. 9 beams IMRT plan with equal division angle were designed for every patients, and the prescription dosemore » for tumor target was set as 72Gy (2.4Gy/ fration). The boundary display, volume and dose-volume indices of each organ were compared between on MRI and CT images. Results: Compared to CT, MRI showed clearer boundary of brainstem, spinal cord, the deep lobe of Parotid gland and the optical nerve in canal. MRI images increase the volume of lens, optical nerve, while reducing the volume of eye slightly, and the maximum dose of lens, the mean dose of eyes and optical raised in different percentage, while there was no statistical differences were found. The left and right parotid volume on MRI increased by 7.07%, 8.13%, and the mean dose raised by 14.95% (4.01Gy), 18.76% (4.95Gy) with statistical significant difference (p<0.05). The brainstem volume reduced by 9.33% (p<0.05), and the dose of 0.1cm3 volume (D0.1cm3) reduced by mean 8.46% (4.32Gy), and D0.1cm3 of spinal cord increased by 1.5Gy on MRI. Conclusion: It is credible to evaluate the radiation dose of lens, eye and the spinal cord, while it should be necessary to evaluate the dose of brainstem, parotid and the optical nerve applying MRI images sometime, it will be more meaningful for these organs with high risk of radiation injury.« less

  2. TU-AB-202-05: GPU-Based 4D Deformable Image Registration Using Adaptive Tetrahedral Mesh Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong, Z; Zhuang, L; Gu, X

    Purpose: Deformable image registration (DIR) has been employed today as an automated and effective segmentation method to transfer tumor or organ contours from the planning image to daily images, instead of manual segmentation. However, the computational time and accuracy of current DIR approaches are still insufficient for online adaptive radiation therapy (ART), which requires real-time and high-quality image segmentation, especially in a large datasets of 4D-CT images. The objective of this work is to propose a new DIR algorithm, with fast computational speed and high accuracy, by using adaptive feature-based tetrahedral meshing and GPU-based parallelization. Methods: The first step ismore » to generate the adaptive tetrahedral mesh based on the image features of a reference phase of 4D-CT, so that the deformation can be well captured and accurately diffused from the mesh vertices to voxels of the image volume. Subsequently, the deformation vector fields (DVF) and other phases of 4D-CT can be obtained by matching each phase of the target 4D-CT images with the corresponding deformed reference phase. The proposed 4D DIR method is implemented on GPU, resulting in significantly increasing the computational efficiency due to its parallel computing ability. Results: A 4D NCAT digital phantom was used to test the efficiency and accuracy of our method. Both the image and DVF results show that the fine structures and shapes of lung are well preserved, and the tumor position is well captured, i.e., 3D distance error is 1.14 mm. Compared to the previous voxel-based CPU implementation of DIR, such as demons, the proposed method is about 160x faster for registering a 10-phase 4D-CT with a phase dimension of 256×256×150. Conclusion: The proposed 4D DIR method uses feature-based mesh and GPU-based parallelism, which demonstrates the capability to compute both high-quality image and motion results, with significant improvement on the computational speed.« less

  3. Impact of the Adaptive Statistical Iterative Reconstruction Technique on Radiation Dose and Image Quality in Bone SPECT/CT.

    PubMed

    Sibille, Louis; Chambert, Benjamin; Alonso, Sandrine; Barrau, Corinne; D'Estanque, Emmanuel; Al Tabaa, Yassine; Collombier, Laurent; Demattei, Christophe; Kotzki, Pierre-Olivier; Boudousq, Vincent

    2016-07-01

    The purpose of this study was to compare a routine bone SPECT/CT protocol using CT reconstructed with filtered backprojection (FBP) with an optimized protocol using low-dose CT images reconstructed with adaptive statistical iterative reconstruction (ASiR). In this prospective study, enrolled patients underwent bone SPECT/CT, with 1 SPECT acquisition followed by 2 randomized CT acquisitions: FBP CT (FBP; noise index, 25) and ASiR CT (70% ASiR; noise index, 40). The image quality of both attenuation-corrected SPECT and CT images was visually (5-point Likert scale, 2 interpreters) and quantitatively (contrast ratio [CR] and signal-to-noise ratio [SNR]) estimated. The CT dose index volume, dose-length product, and effective dose were compared. Seventy-five patients were enrolled in the study. Quantitative attenuation-corrected SPECT evaluation showed no inferiority for contrast ratio and SNR issued from FBP CT or ASiR CT (respectively, 13.41 ± 7.83 vs. 13.45 ± 7.99 and 2.33 ± 0.83 vs. 2.32 ± 0.84). Qualitative image analysis showed no difference between attenuation-corrected SPECT images issued from FBP CT or ASiR CT for both interpreters (respectively, 3.5 ± 0.6 vs. 3.5 ± 0.6 and 3.6 ± 0.5 vs. 3.6 ± 0.5). Quantitative CT evaluation showed no inferiority for SNR between FBP and ASiR CT images (respectively, 0.93 ± 0.16 and 1.07 ± 0.17). Qualitative image analysis showed no quality difference between FBP and ASiR CT images for both interpreters (respectively, 3.8 ± 0.5 vs. 3.6 ± 0.5 and 4.0 ± 0.1 vs. 4.0 ± 0.2). Mean CT dose index volume, dose-length product, and effective dose for ASiR CT (3.0 ± 2.0 mGy, 148 ± 85 mGy⋅cm, and 2.2 ± 1.3 mSv) were significantly lower than for FBP CT (8.5 ± 3.7 mGy, 365 ± 160 mGy⋅cm, and 5.5 ± 2.4 mSv). The use of 70% ASiR blending in bone SPECT/CT can reduce the CT radiation dose by 60%, with no sacrifice in attenuation-corrected SPECT and CT image quality, compared with the conventional protocol using FBP CT reconstruction technique. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  4. Clinical Utility of Multimodality Imaging with Dynamic Contrast-Enhanced MRI, Diffusion-Weighted MRI, and 18F-FDG PET/CT for the Prediction of Neck Control in Oropharyngeal or Hypopharyngeal Squamous Cell Carcinoma Treated with Chemoradiation

    PubMed Central

    Chan, Sheng-Chieh; Lin, Yu-Chun; Yen, Tzu-Chen; Liao, Chun-Ta; Chang, Joseph Tung-Chieh; Ko, Sheung-Fat; Wang, Hung- Ming; Chang, Chee-Jen; Wang, Jiun-Jie

    2014-01-01

    The clinical usefulness of pretreatment imaging techniques for predicting neck control in patients with oropharyngeal or hypopharyngeal squamous cell carcinoma (OHSCC) treated with chemoradiation remains unclear. In this prospective study, we investigated the role of pretreatment dynamic contrast-enhanced perfusion MR imaging (DCE-PWI), diffusion-weighted MR imaging (DWI), and [18F]fluorodeoxyglucose-positron emission tomography (18F-FDG PET)/CT derived imaging markers for the prediction of neck control in OHSCC patients treated with chemoradiation. Patients with untreated OHSCC scheduled for chemoradiation between August, 2010 and July, 2012 were eligible for the study. Clinical variables and the following imaging parameters of metastatic neck lymph nodes were examined in relation to neck control: transfer constant, volume of blood plasma, and volume of extracellular extravascular space (Ve) on DCE-PWI; apparent diffusion coefficient (ADC) on DWI; maximum standardized uptake value, metabolic tumor volume, and total lesion glycolysis on 18F-FDG PET/CT. There were 69 patients (37 with oropharynx SCC and 32 with hypopharynx SCC) with successful pretreatment DCE-PWI and DWI available for analysis. After a median follow-up of 31 months, 25 (36.2%) participants had neck failure. Multivariate analysis identified hemoglobin level <14.3 g/dL (P = 0.019), Ve <0.23 (P = 0.040), and ADC >1.14×10−3 mm2/s (P = 0.003) as independent prognostic factors for 3-year neck control. A prognostic scoring system was formulated by summing up the three significant predictors of neck control. Patients with scores of 2–3 had significantly poorer neck control and overall survival rates than patients with scores of 0–1. We conclude that hemoglobin levels, Ve, and ADC are independent pretreatment prognostic factors for neck control in OHSCC treated with chemoradiation. Their combination may identify a subgroup of patients at high risk of developing neck failure. PMID:25531391

  5. Diffuse thyroid 18F-FDG uptake after R-CHOP therapy predicts favorable outcome in patients with DLBCL.

    PubMed

    Song, Moo-Kon; Chung, Joo-Seop; Kim, Seong-Jang; Kim, Sang-Soo; Shin, Ho-Jin

    2015-06-01

    Therapy-induced autoimmunity may mediate the destruction of cancer cells. Previous studies have demonstrated that presence of autoimmune thyroid disorder is associated with favorable outcome in patients with solid cancer. Patients with diffuse large B cell lymphoma (DLBCL) who achieved complete response on positron emission tomography/computed tomography (PET/CT) after rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone (R-CHOP) therapy were enrolled in this study. The patients with and without diffuse thyroid uptake (DTU) were classified by PET/CT. A total of 270 patients were enrolled in this study. DTU related to autoimmune thyroiditis was present in 61 patients. The median time to DTU detection was 5.7 months (range, 0-21.3 months). High International Prognostic Index (IPI) score (progression-free survival [PFS], p = 0.001; overall survival [OS], p = 0.008), bulky mass ≥10 cm (PFS, p = 0.001; OS, p = 0.001), bone marrow involvement (PFS, p < 0.001; OS, p = 0.001), and DTU after R-CHOP therapy (PFS, p < 0.001; OS, p = 0.001) were significantly associated with PFS and OS. High IPI score (PFS, p = 0.003; OS, p = 0.014), BM involvement (PFS, p = 0.009; OS, p = 0.039), and DTU after R-CHOP therapy (PFS, p = 0.002; OS, p = 0.002) were independently associated with PFS and OS. DTU after R-CHOP therapy independently predicted favorable outcomes in patients with DLBCL.

  6. Disease Severity in Patients Infected with Leishmania mexicana Relates to IL-1β

    PubMed Central

    Fernández-Figueroa, Edith A.; Rangel-Escareño, Claudia; Espinosa-Mateos, Valeria; Carrillo-Sánchez, Karol; Salaiza-Suazo, Norma; Carrada-Figueroa, Georgina; March-Mifsut, Santiago; Becker, Ingeborg

    2012-01-01

    Leishmania mexicana can cause both localized (LCL) and diffuse (DCL) cutaneous leishmaniasis, yet little is known about factors regulating disease severity in these patients. We analyzed if the disease was associated with single nucleotide polymorphisms (SNPs) in IL-1β (−511), CXCL8 (−251) and/or the inhibitor IL-1RA (+2018) in 58 Mexican mestizo patients with LCL, 6 with DCL and 123 control cases. Additionally, we analyzed the in vitro production of IL-1β by monocytes, the expression of this cytokine in sera of these patients, as well as the tissue distribution of IL-1β and the number of parasites in lesions of LCL and DCL patients. Our results show a significant difference in the distribution of IL-1β (−511 C/T) genotypes between patients and controls (heterozygous OR), with respect to the reference group CC, which was estimated with a value of 3.23, 95% CI = (1.2, 8.7) and p-value = 0.0167), indicating that IL-1β (−511 C/T) represents a variable influencing the risk to develop the disease in patients infected with Leishmania mexicana. Additionally, an increased in vitro production of IL-1β by monocytes and an increased serum expression of the cytokine correlated with the severity of the disease, since it was significantly higher in DCL patients heavily infected with Leishmania mexicana. The distribution of IL-1β in lesions also varied according to the number of parasites harbored in the tissues: in heavily infected LCL patients and in all DCL patients, the cytokine was scattered diffusely throughout the lesion. In contrast, in LCL patients with lower numbers of parasites in the lesions, IL-1β was confined to the cells. These data suggest that IL-1β possibly is a key player determining the severity of the disease in DCL patients. The analysis of polymorphisms in CXCL8 and IL-1RA showed no differences between patients with different disease severities or between patients and controls. PMID:22629474

  7. Super-refractory nonconvulsive status epilepticus secondary to fat embolism: A clinical, electrophysiological, and pathological study.

    PubMed

    Fernández-Torre, José L; Burgueño, Paula; Ballesteros, María A; Hernández-Hernández, Miguel A; Villagrá-Terán, Nuria; de Lucas, Enrique Marco

    2015-08-01

    Fat embolism syndrome (FES) is a rare complication of long-bone fractures and joint reconstruction surgery. To the best of our knowledge, we describe the clinical, electrophysiological, neuroimaging, and neuropathological features of the first case of super-refractory nonconvulsive status epilepticus (sr-NCSE) secondary to fat embolism. An 82-year-old woman was transferred to our intensive care unit because of a sudden decrease of consciousness level, right hemiparesis, and acute respiratory failure in the early postoperative period of knee prosthesis surgery. Brain computed tomography (TC) including angio-CT and CT perfusion was normal. An urgent video-electroencephalography (v-EEG) evaluation showed continuous sharp-and slow-wave at 2.0-2.5 Hz in keeping with the diagnosis of generalized NCSE. Epileptiform discharges ceased after the administration of 5mg of intravenous diazepam, and background activity constituted by diffuse theta waves was observed without clinical improvement. Treatment with levetiracetam (1000 mg/day) and sedation with propofol and midazolam were initiated. Moreover, continuous v-EEG monitoring was also started. Despite antiepileptic therapy, epileptiform activity recurred after the interruption of profound sedation, and valproate and lacosamide were added during the ensuing days. Magnetic resonance imaging (MRI) disclosed small scattered foci of acute ischemic infarcts and diffuse petechiae involving the basal ganglia and pons and centrum semiovale in keeping with fat embolism. Super-refractory nonconvulsive status epilepticus remained without control for 2 weeks. Finally, the patient died. The clinical autopsy revealed a bilateral lung fat embolism associated with a hemorrhagic infarction in the left lower lobe. Fatty lesions were also seen in the intestine and pancreas. Scattered microscopic cerebral infarcts associated with fat emboli in the capillaries were noticed, affecting both supra- and infratentorial structures. In addition, occasional focal areas of ischemic injury showing filiform neurons with reactive astrocytic gliosis background consistent with acute lesions were observed in CA3. Fat embolism should be considered a potential cause of sr-NCSE. This article is part of a Special Issue entitled "Status Epilepticus". Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Treatment response assessment of radiofrequency ablation for hepatocellular carcinoma: usefulness of virtual CT sonography with magnetic navigation.

    PubMed

    Minami, Yasunori; Kitai, Satoshi; Kudo, Masatoshi

    2012-03-01

    Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. Sixty-one patients with 88 HCCs measuring 0.5-1.3 cm (mean±SD, 1.0±0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1-5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P=0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P=0.13). The safety margin should be overestimated on axial CT images in 8 nodules. Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    PubMed

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P < 0.005). On average, 2.6 more organs with concomitant metastases were found when SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Internal Carotid Artery Agenesis with an Intercavernous Anastomosis: A Rare Case.

    PubMed

    Erdogan, Mucahid; Senadim, Songul; Ince Yasinoglu, K Nur; Selcuk, H Hakan; Atakli, H Dilek

    2017-10-01

    Agenesis of the internal carotid artery (ICA) is a rare vascular anomaly that was first observed postmortem. Various anastomoses supply the distal vessels at the site of agenesis. Of these anastomoses, an intercavernous anastomosis is very rare. This paper presents a patient with ischemic stroke in whom we discovered left ICA agenesis and an ipsilateral intercavernous anastomosis. A 58-year-old man with a history of myocardial infarction and diabetes mellitus presented with sudden-onset difficulty in speaking, numbness on the left side of the face, and weakness of the left arm and leg. Neurological examination revealed dysarthria, left facial paralysis, left hemiparesis, and bilateral absence of the plantar reflexes. Diffusion-weighted magnetic resonance imaging showed a right middle cerebral artery (MCA) infarction. On cranial and cervical magnetic resonance angiography, the left ICA could not be seen distal to the bifurcation; the left MCA was supplied through an intercavernous anastomosis between the right ICA and the left ICA. Cranial computed tomography (CT) revealed the absence of the left carotid canal. Digital subtraction angiography led to a diagnosis of left ICA agenesis with an intercavernous anastomosis. The patient was discharged on acetylsalicylic acid and warfarin. ICA agenesis with an intercavernous anastomosis is a rare vascular anomaly that should be differentiated from secondary causes of ICA stenosis and occlusions by showing agenesis of the carotid canal on cranial CT. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  11. Synthesis, structural elucidation, biological, antioxidant and nuclease activities of some 5-Fluorouracil-amino acid mixed ligand complexes

    NASA Astrophysics Data System (ADS)

    Shobana, Sutha; Subramaniam, Perumal; Mitu, Liviu; Dharmaraja, Jeyaprakash; Arvind Narayan, Sundaram

    2015-01-01

    Some biologically active mixed ligand complexes (1-9) have been synthesized from 5-Fluorouracil (5-FU; A) and amino acids (B) such as glycine (gly), L-alanine (ala) and L-valine (val) with Ni(II), Cu(II) and Zn(II) ions. The synthesized mixed ligand complexes (1-9) were characterized by various physico-chemical, spectral, thermal and morphological studies. 5-Fluorouracil and its mixed ligand complexes have been tested for their in vitro biological activities against some pathogenic bacterial and fungal species by the agar well diffusion method. The in vitro antioxidant activities of 5-Fluorouracil and its complexes have also been investigated by using the DPPH assay method. The results demonstrate that Cu(II) mixed ligand complexes (4-6) exhibit potent biological as well as antioxidant activities compared to 5-Fluorouracil and Ni(II) (1-3) and Zn(II) (7-9) mixed ligand complexes. Further, the cleaving activities of CT DNA under aerobic conditions show moderate activity with the synthesized Cu(II) and Ni(II) mixed ligand complexes (1-6) while no activity is seen with Zn(II) complexes (7-9). Binding studies of CT DNA with these complexes show a decrease in intensity of the charge transfer band to the extent of 5-15% along with a minor red shift. The free energy change values (Δ‡G) calculated from intrinsic binding constants indicate that the interaction between mixed ligand complex and DNA is spontaneous.

  12. Diffuse Peritoneal and Bowel Wall Infiltration by Light Chain-AL Amyloidosis with Omental Calcification Mimicking Abdominal Carcinomatosis - An Elderly Female with Incidental Finding of Light Chain Monoclonal Gammopathy of Undetermined Significance (LC-MGUS).

    PubMed

    Junejo, Shoaib; Ali, Yasir; Singh Lubana, Sandeep; Tuli, Sandeep S

    2017-11-25

    BACKGROUND Amyloidosis is the extracellular tissue deposition of plasma proteins, which after conformational changes, forms antiparallel beta pleated sheets of fibrils. Amyloid light-chain (AL) is a type of amyloidosis that is due to deposition of proteins derived from immunoglobulin (Ig) light chains. Gastrointestinal tract (GIT) involvement most often found in amyloid A (AA) amyloidosis type. There have been no reports of obstructive GIT AL amyloid patients having monoclonal gammopathy of undetermined significance (MGUS). Our case is the first case to show two coinciding conditions; one is the association of GIT AL amyloidosis with the incidental finding of a rare type of MGUS (LC-MGUS) and the other is the radiologic presentation of GIT amyloidosis with omental calcification mimicking the GIT malignancy. CASE REPORT A 68-year-old female presented with symptoms of partial bowel obstruction, including intermittent diffuse abdominal pain and constipation. After computed tomography (CT) abdomen and pelvis, an exploratory laparotomy was needed because of suspicion of abdominal carcinomatosis due to diffuse omental calcification. The tissue sent for biopsy surprisingly showed AL amyloidosis. The patient did not report any systemic symptoms. Further workup was advised to inquire about the plasma cell dyscrasia which eventually turned into a very rare version of MGUS knows as light chain MGUS (LC-MGUS). Following adequate resection of the involved structures, the patient was then placed on chemotherapy and successfully went into remission. CONCLUSIONS This case report illustrates that in an era of evidence based medicine, it is important to show through case reports the association of GIT AL amyloidosis with LC-MGUS, as the literature on this topic is lacking. It also points to the importance of timely intervention that can greatly enhance, not only the only the chances of remission but also prevention of further complications such as malignant transformation.

  13. Radiotherapy volume delineation using 18F-FDG-PET/CT modifies gross node volume in patients with oesophageal cancer.

    PubMed

    Jimenez-Jimenez, E; Mateos, P; Aymar, N; Roncero, R; Ortiz, I; Gimenez, M; Pardo, J; Salinas, J; Sabater, S

    2018-05-02

    Evidence supporting the use of 18F-FDG-PET/CT in the segmentation process of oesophageal cancer for radiotherapy planning is limited. Our aim was to compare the volumes and tumour lengths defined by fused PET/CT vs. CT simulation. Twenty-nine patients were analyzed. All patients underwent a single PET/CT simulation scan. Two separate GTVs were defined: one based on CT data alone and another based on fused PET/CT data. Volume sizes for both data sets were compared and the spatial overlap was assessed by the Dice similarity coefficient (DSC). The gross tumour volume (GTVtumour) and maximum tumour diameter were greater by PET/CT, and length of primary tumour was greater by CT, but differences were not statistically significant. However, the gross node volume (GTVnode) was significantly greater by PET/CT. The DSC analysis showed excellent agreement for GTVtumour, 0.72, but was very low for GTVnode, 0.25. Our study shows that the volume definition by PET/CT and CT data differs. CT simulation, without taking into account PET/CT information, might leave cancer-involved nodes out of the radiotherapy-delineated volumes.

  14. Circulating tumour DNA and CT monitoring in patients with untreated diffuse large B-cell lymphoma: a correlative biomarker study.

    PubMed

    Roschewski, Mark; Dunleavy, Kieron; Pittaluga, Stefania; Moorhead, Martin; Pepin, Francois; Kong, Katherine; Shovlin, Margaret; Jaffe, Elaine S; Staudt, Louis M; Lai, Catherine; Steinberg, Seth M; Chen, Clara C; Zheng, Jianbiao; Willis, Thomas D; Faham, Malek; Wilson, Wyndham H

    2015-05-01

    Diffuse large-B-cell lymphoma is curable, but when treatment fails, outcome is poor. Although imaging can help to identify patients at risk of treatment failure, they are often imprecise, and radiation exposure is a potential health risk. We aimed to assess whether circulating tumour DNA encoding the clonal immunoglobulin gene sequence could be detected in the serum of patients with diffuse large-B-cell lymphoma and used to predict clinical disease recurrence after frontline treatment. We used next-generation DNA sequencing to retrospectively analyse cell-free circulating tumour DNA in patients assigned to one of three treatment protocols between May 8, 1993, and June 6, 2013. Eligible patients had diffuse large-B-cell lymphoma, no evidence of indolent lymphoma, and were previously untreated. We obtained serial serum samples and concurrent CT scans at specified times during most treatment cycles and up to 5 years of follow-up. VDJ gene segments of the rearranged immunoglobulin receptor genes were amplified and sequenced from pretreatment specimens and serum circulating tumour DNA encoding the VDJ rearrangements was quantitated. Tumour clonotypes were identified in pretreatment specimens from 126 patients who were followed up for a median of 11 years (IQR 6·8-14·2). Interim monitoring of circulating tumour DNA at the end of two treatment cycles in 108 patients showed a 5-year time to progression of 41·7% (95% CI 22·2-60·1) in patients with detectable circulating tumour DNA and 80·2% (69·6-87·3) in those without detectable circulating tumour DNA (p<0·0001). Detectable interim circulating tumour DNA had a positive predictive value of 62·5% (95% CI 40·6-81·2) and a negative predictive value of 79·8% (69·6-87·8). Surveillance monitoring of circulating tumour DNA was done in 107 patients who achieved complete remission. A Cox proportional hazards model showed that the hazard ratio for clinical disease progression was 228 (95% CI 51-1022) for patients who developed detectable circulating tumour DNA during surveillance compared with patients with undetectable circulating tumour DNA (p<0·0001). Surveillance circulating tumour DNA had a positive predictive value of 88·2% (95% CI 63·6-98·5) and a negative predictive value of 97·8% (92·2-99·7) and identified risk of recurrence at a median of 3·5 months (range 0-200) before evidence of clinical disease. Surveillance circulating tumour DNA identifies patients at risk of recurrence before clinical evidence of disease in most patients and results in a reduced disease burden at relapse. Interim circulating tumour DNA is a promising biomarker to identify patients at high risk of treatment failure. National Cancer Institute and Adaptive Biotechnologies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Follow-up CT findings of tamoxifen-induced non-alcoholic steatohepatitis (NASH) of breast cancer patients treated with bezafibrate.

    PubMed

    Ogawa, Yasuhiro; Murata, Yoriko; Saibara, Toshiji; Nishioka, Akihito; Kariya, Shinji; Yoshida, Shoji

    2003-01-01

    One-third of the breast cancer patients who underwent tamoxifen intake showed less than 0.9 of their liver/spleen CT (computed tomography) ratio on their annual CT study, and were diagnosed as having fatty liver (hepatic steatosis). Among them, patients who showed a lower liver/spleen CT ratio of less than 0.5 were recommended to undergo needle biopsy of the liver in order to obtain histopathological confirmation of non-alcoholic steatohepatitis (NASH), with 15 patients undergoing needle biopsy of the liver. As a result, 14 out of the 15 patients were diagnosed as having NASH, and these patients were additionally administered bezafibrate in order to prevent possible progressive changes of NASH into liver cirrhosis. In this study, we show the changes of follow-up CT findings of 6 patients with histopathologically-proven NASH who continued to undergo bezafibrate intake after the diagnosis of NASH. Two patients showed almost complete improvement as indicated by the liver/spleen CT ratio several months after completion of a tamoxifen intake of 5 years, and another 3 showed partial improvement on their liver/spleen CT ratio by bezafibrate intake in spite of continuing tamoxifen intake. Another patient with diabetes mellitus (type II) showed a continually decreasing liver/spleen CT ratio during adjuvant tamoxifen in spite of bezafibrate intake. Therefore, we concluded that the progression of NASH could be prevented by bezafibrate without any interruption of adjuvant tamoxifen treatment. For patients with diabetes mellitus, critical follow-up using CT study and laboratory tests is considered essential.

  16. The combination of preoperative PET/CT and sentinel lymph node biopsy in the surgical management of early-stage cervical cancer.

    PubMed

    Papadia, Andrea; Gasparri, Maria Luisa; Genoud, Sophie; Bernd, Klaeser; Mueller, Michael D

    2017-11-01

    The aim of the study was to evaluate the use of PET/CT and/or SLN mapping alone or in combination in cervical cancer patients. Data on stage IA1-IIA cervical cancer patients undergoing PET/CT and SLN mapping were retrospectively collected. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of PET/CT and SLN mapping, alone or in combination, in identifying cervical cancer patients with lymph node metastases were calculated. Sixty patients met the inclusion criteria. PET/CT showed a sensitivity of 68%, a specificity of 84%, a PPV of 61% and a NPV of 88% in detecting lymph nodal metastases. SLN mapping showed a sensitivity of 93%, a specificity of 100%, a PPV of 100% and a NPV of 97%. The combination of PET/CT and SLN mapping showed a sensitivity of 100%, a specificity of 86%, a PPV of 72% and a NPV of 100%. For patients with tumors of >2 cm in diameter, the PET/CT showed a sensitivity of 68%, a specificity of 72%, a PPV of 61% and a NPV of 86%. SLN mapping showed a sensitivity of 93%, a specificity of 100%, a PPV of 100% and a NPV of 95%. The combination of PET/CT and SLN mapping showed a sensitivity of 100%, a specificity of 76%, a PPV of 72% and a NPV of 100%. PET/CT represents a "safety net" that helps the surgeon in identifying metastatic lymph nodes, especially in patients with larger tumors.

  17. Imaging in rectal cancer with emphasis on local staging with MRI

    PubMed Central

    Arya, Supreeta; Das, Deepak; Engineer, Reena; Saklani, Avanish

    2015-01-01

    Imaging in rectal cancer has a vital role in staging disease, and in selecting and optimizing treatment planning. High-resolution MRI (HR-MRI) is the recommended method of first choice for local staging of rectal cancer for both primary staging and for restaging after preoperative chemoradiation (CT-RT). HR-MRI helps decide between upfront surgery and preoperative CT-RT. It provides high accuracy for prediction of circumferential resection margin at surgery, T category, and nodal status in that order. MRI also helps assess resectability after preoperative CT-RT and decide between sphincter saving or more radical surgery. Accurate technique is crucial for obtaining high-resolution images in the appropriate planes for correct staging. The phased array external coil has replaced the endorectal coil that is no longer recommended. Non-fat suppressed 2D T2-weighted (T2W) sequences in orthogonal planes to the tumor are sufficient for primary staging. Contrast-enhanced MRI is considered inappropriate for both primary staging and restaging. Diffusion-weighted sequence may be of value in restaging. Multidetector CT cannot replace MRI in local staging, but has an important role for evaluating distant metastases. Positron emission tomography-computed tomography (PET/CT) has a limited role in the initial staging of rectal cancer and is reserved for cases with resectable metastatic disease before contemplating surgery. This article briefly reviews the comprehensive role of imaging in rectal cancer, describes the role of MRI in local staging in detail, discusses the optimal MRI technique, and provides a synoptic report for both primary staging and restaging after CT-RT in routine practice. PMID:25969638

  18. Automated Quantitative Computed Tomography Versus Visual Computed Tomography Scoring in Idiopathic Pulmonary Fibrosis: Validation Against Pulmonary Function.

    PubMed

    Jacob, Joseph; Bartholmai, Brian J; Rajagopalan, Srinivasan; Kokosi, Maria; Nair, Arjun; Karwoski, Ronald; Raghunath, Sushravya M; Walsh, Simon L F; Wells, Athol U; Hansell, David M

    2016-09-01

    The aim of the study was to determine whether a novel computed tomography (CT) postprocessing software technique (CALIPER) is superior to visual CT scoring as judged by functional correlations in idiopathic pulmonary fibrosis (IPF). A total of 283 consecutive patients with IPF had CT parenchymal patterns evaluated quantitatively with CALIPER and by visual scoring. These 2 techniques were evaluated against: forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), diffusing capacity for carbon monoxide (DLco), carbon monoxide transfer coefficient (Kco), and a composite physiological index (CPI), with regard to extent of interstitial lung disease (ILD), extent of emphysema, and pulmonary vascular abnormalities. CALIPER-derived estimates of ILD extent demonstrated stronger univariate correlations than visual scores for most pulmonary function tests (PFTs): (FEV1: CALIPER R=0.29, visual R=0.18; FVC: CALIPER R=0.41, visual R=0.27; DLco: CALIPER R=0.31, visual R=0.35; CPI: CALIPER R=0.48, visual R=0.44). Correlations between CT measures of emphysema extent and PFTs were weak and did not differ significantly between CALIPER and visual scoring. Intriguingly, the pulmonary vessel volume provided similar correlations to total ILD extent scored by CALIPER for FVC, DLco, and CPI (FVC: R=0.45; DLco: R=0.34; CPI: R=0.53). CALIPER was superior to visual scoring as validated by functional correlations with PFTs. The pulmonary vessel volume, a novel CALIPER CT parameter with no visual scoring equivalent, has the potential to be a CT feature in the assessment of patients with IPF and requires further exploration.

  19. Diffusion Lung Imaging with Hyperpolarized Gas MRI

    PubMed Central

    Yablonskiy, Dmitriy A; Sukstanskii, Alexander L; Quirk, James D

    2015-01-01

    Lung imaging using conventional 1H MRI presents great challenges due to low density of lung tissue, lung motion and very fast lung tissue transverse relaxation (typical T2* is about 1-2 ms). MRI with hyperpolarized gases (3He and 129Xe) provides a valuable alternative due to a very strong signal originated from inhaled gas residing in the lung airspaces and relatively slow gas T2* relaxation (typical T2* is about 20-30 ms). Though in vivo human experiments should be done very fast – usually during a single breath-hold. In this review we describe the recent developments in diffusion lung MRI with hyperpolarized gases. We show that a combination of modeling results of gas diffusion in lung airspaces and diffusion measurements with variable diffusion-sensitizing gradients allows extracting quantitative information on the lung microstructure at the alveolar level. This approach, called in vivo lung morphometry, allows from a less than 15-second MRI scan, providing quantitative values and spatial distributions of the same physiological parameters as are measured by means of the “standard” invasive stereology (mean linear intercept, surface-to-volume ratio, density of alveoli, etc.). Besides, the approach makes it possible to evaluate some advanced Weibel parameters characterizing lung microstructure - average radii of alveolar sacs and ducts, as well as the depth of their alveolar sleeves. Such measurements, providing in vivo information on the integrity of pulmonary acinar airways and their changes in different diseases, are of great importance and interest to a broad range of physiologists and clinicians. We also discuss a new type of experiments that are based on the in vivo lung morphometry technique combined with quantitative CT measurements as well as with the Gradient Echo MRI measurements of hyperpolarized gas transverse relaxation in the lung airspaces. Such experiments provide additional information on the blood vessel volume fraction, specific gas volume, the length of acinar airways, and allows evaluation of lung parenchymal and non-parenchymal tissue. PMID:26676342

  20. 68Ga DOTA-TATE PET/CT allows tumor localization in patients with tumor-induced osteomalacia but negative 111In-octreotide SPECT/CT.

    PubMed

    Breer, Stefan; Brunkhorst, Thomas; Beil, F Timo; Peldschus, Kersten; Heiland, Max; Klutmann, Susanne; Barvencik, Florian; Zustin, Jozef; Gratz, Klaus-Friedrich; Amling, Michael

    2014-07-01

    Tumor-induced osteomalacia (TIO) is a paraneoplastic syndrome characterized by renal phosphate wasting, hypophosphatemia and low calcitriol levels as well as clinical symptoms like diffuse bone and muscle pain, fatigue fractures or increased fracture risk. Conventional imaging methods, however, often fail to detect the small tumors. Lately, tumor localization clearly improved by somatostatin-receptor (SSTR) imaging, such as octreotide scintigraphy or octreotide SPECT/CT. However, recent studies revealed that still a large number of tumors remained undetected by octreotide imaging. Hence, studies focused on different SSTR imaging methods such as 68Ga DOTA-NOC, 68Ga DOTA-TOC and 68Ga DOTA-TATE PET/CT with promising first results. Studies comparing different SSTR imaging methods for tumor localization in TIO are rare and thus little is known about diagnostic alternatives once a particular method failed to detect a tumor in patients with TIO. Here, we report the data of 5 consecutive patients suffering from TIO, who underwent both 111Indium-octreotide scintigraphy (111In-OCT) SPECT/CT as well as 68Ga DOTA-TATE PET/CT for tumor detection. While 111In-OCT SPECT/CT allowed tumor detection in only 1 of 5 patients, 68Ga DOTA-TATE PET/CT was able to localize the tumor in all patients. Afterwards, anatomical imaging of the region of interest was performed with CT and MRI. Thus, successful surgical resection of the tumor was achieved in all patients. Serum phosphate levels returned to normal and all patients reported relief of symptoms within weeks. Moreover, an iliac crest biopsy was obtained from every patient and revealed marked osteomalacia in all cases. Follow-up DXA revealed an increase in BMD of up to 34.5% 1-year postoperative, indicating remineralization. No recurrence was observed. In conclusion our data indicates that 68Ga DOTA-TATE PET/CT is an effective and promising diagnostic tool in the diagnosis of TIO, even in patients in whom 111In-OCT prior failed to detect a tumor. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Innovations in imaging modalities for recurrent and metastatic prostate cancer: a systematic review.

    PubMed

    Albisinni, Simone; Aoun, Fouad; Marcelis, Quentin; Jungels, Claude; Al Hajj Obeid, Walid; Zanaty, Marc; Tubaro, Andrea; Roumeguere, Thierry; DE Nunzio, Cosimo

    2018-01-31

    The last decade has witnessed tremendous changes in the management of advanced and metastatic castration resistant prostate cancer (mCRPC). In the current systematic review, we analyze novel imaging techniques in the setting of recurrent and metastatic PCa, exploring available data and highlighting future exams which could enter clinical practice in the upcoming years. The National Library of Medicine Database was searched for relevant articles published between January 2012 and August 2017. A wide search was performed including the combination of following words: "Prostate" AND "Cancer" AND ("Metastatic" OR "Recurrent") AND "imaging" AND ("MRI" OR "PET"). The selection procedure followed the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) principles and is presented using a PRISMA flow chart. Novel imaging techniques, as multiparametric MRI, whole-body MRI and Choline and PSMA PET imaging techniques are currently revolutioning the treatment planning in patients with advanced and metastatic PCa, allowing a better characterization of the disease. Multiparametric MRI performs well in the detection of local recurrences, with sensitivity rates of 67-98% and overall diagnostic accuracy of 83-93%, depending on the type of magnetic field strength (1.5 vs 3T). Whole body MRI instead shows a high specificity (>95%) for bone metastases. PET imaging, and in particular PSMA PET/CT, showed promising results in the detection of both local and distant recurrences, even for low PSA values (<0.5ng/ml). Sensitivity varies from 77-98% depending on PSA value and PSA velocity. Whole body-MRI, NaF PET, Choline-PET/CT and PSMA PET/CT are flourishing techniques which find great application in the field of recurrent and metastatic PCa, in the effort to reduce treatment of "PSA only" and rather focus our therapies on clinical tumor entities. Standardization is urgently needed to allow adequate comparison of results and diffusion on a large scale.

  2. Increased Intracranial Pressure during Hemodialysis in a Patient with Anoxic Brain Injury

    PubMed Central

    Damholt, Mette B.; Strange, Ditte G.; Kelsen, Jesper; Møller-Sørensen, Hasse; Møller, Kirsten

    2017-01-01

    Dialysis disequilibrium syndrome (DDS) is a serious neurological complication of hemodialysis, and patients with acute brain injury are at increased risk. We report a case of DDS leading to intracranial hypertension in a patient with anoxic brain injury and discuss the subsequent dialysis strategy. A 13-year-old girl was admitted after prolonged resuscitation from cardiac arrest. Computed tomography (CT) revealed an inferior vena cava aneurysm and multiple pulmonary emboli as the likely cause. An intracranial pressure (ICP) monitor was inserted, and, on day 3, continuous renal replacement therapy (CRRT) was initiated due to acute kidney injury, during which the patient developed severe intracranial hypertension. CT of the brain showed diffuse cerebral edema. CRRT was discontinued, sedation was increased, and hypertonic saline was administered, upon which ICP normalized. Due to persistent hyperkalemia and overhydration, ultrafiltration and intermittent hemodialysis were performed separately on day 4 with a small dialyzer, low blood and dialysate flow, and high dialysate sodium content. During subsequent treatments, isolated ultrafiltration was well tolerated, whereas hemodialysis was associated with increased ICP necessitating frequent pauses or early cessation of dialysis. In patients at risk of DDS, hemodialysis should be performed with utmost care and continuous monitoring of ICP should be considered. PMID:28409034

  3. Radiation recall gastritis secondary to combination of gemcitabine and erlotinib in pancreatic cancer and response to PPI - a case report.

    PubMed

    Choi, Seong Ji; Kim, Hyo Jung; Kim, Jae Seon; Bak, Young-Tae; Kim, Jun Suk

    2016-08-02

    Radiation recall gastritis is rare but can be induced after concurrent chemoradiation for pancreatic cancer. We report a patient with pancreatic cancer who developed radiation-recall gastritis related to a combination of gemcitabine and erlotinib. A 54-year-old female with unresectable pancreatic cancer received gemcitabine in combination with radiation therapy followed by chemotherapy with gemcitabine and erlotinib. After completing 2 cycles of chemotherapy, the patient had epigastric pain, nausea, and vomiting. Abdominal computed tomography (CT) scan revealed diffuse wall thickening of the stomach, and esophagogastroduodenoscopy (EGD) showed multiple gastric ulcers. The patient was treated with proton pump inhibitors (PPI) and was continued on maintenance chemotherapy. Two months later, the patient presented with the similar symptoms and persistent gastric ulcers were observed during subsequent EGD. Nevertheless, the patient's symptom had resolved with PPI therapy. Thus, the patient underwent maintenance chemotherapy with gemcitabine and erlotinib for additional 4 cycles. Eventually, follow-up abdominal CT Scan and EGD at 6 months demonstrated resolution of the gastric ulcers. Physicians should be aware of the possibility of radiation recall gastritis associated with a combination of gemcitabine and erlotinib. Administration of PPIs may mitigate the adverse effects of gemcitabine and erlotinib in the presence of radiation recall gastritis; however further studies are warranted.

  4. [Comparative evaluation of ultrasonography, computerized tomography, angiography and lipiodol CT in defining extent of hepatocarcinoma. A multicenter study].

    PubMed

    Dalla Palma, L; Pozzi Mucelli, R; Sponza, M; Bartolozzi, C; De Santis, M; Gandini, G; Mannella, P; Matricardi, L; Rossi, C; Simonetti, G

    1995-03-01

    The authors report the results of a multicentric trial on hepatocellular carcinoma (HCC) patients, whose lesions were confirmed with biopsy or by high (> 400 ng/ml) alpha-fetoprotein levels. The series consisted of 149 patients examined in 8 different centers and submitted to ultrasonography (US), Computed Tomography (CT) before and after contrast agent administration, angiography and Lipiodol CT. According to lesion size and number, the patients were divided with each imaging modality into three groups: a) group 1: unifocal HCC < 5 cm diameter; b) group 2: multifocal HCC with 2-3 nodules and/or tumor mass < 80 ml; c) multifocal HCC with more than 3 nodules (with total tumor mass not exceeding 40% of liver volume) or with total tumor mass > 80 ml. In 77 patients all the examinations were available for comparison. US and CT diagnosed more patients as belonging to group 1 than angiography and Lipiodol CT, while more patients were classified as groups 2 and 3 with angiography and Lipiodol CT, meaning that US and CT may understage some HCC cases (about 15%) because they show a lower number of nodules. This observation was confirmed by the direct comparison between US and Lipiodol CT (in 114 patients), CT and Lipiodol CT (in 103 patients) and angiography and Lipiodol CT (in 116 patients). US and Lipiodol CT were in disagreement in 18 cases, CT and Lipiodol CT in 16 cases and angiography and Lipiodol CT in 13 cases. In most of these cases, Lipiodol CT showed more lesions than the other techniques. The size of the undetected lesions was small, ranging few mm to 2 cm in nearly all cases. To conclude, the results of this multicentric trial show that Lipiodol CT is a fundamental tool to evaluate HCC extent. In contrast, conventional CT appeared not to add any significant piece of information and can therefore be excluded from the diagnostic protocol of HCC.

  5. Staging performance of whole-body DWI, PET/CT and PET/MRI in invasive ductal carcinoma of the breast.

    PubMed

    Catalano, Onofrio Antonio; Daye, Dania; Signore, Alberto; Iannace, Carlo; Vangel, Mark; Luongo, Angelo; Catalano, Marco; Filomena, Mazzeo; Mansi, Luigi; Soricelli, Andrea; Salvatore, Marco; Fuin, Niccolo; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce Robert

    2017-07-01

    The aim of the present study was to evaluate the performance of whole-body diffusion-weighted imaging (WB-DWI), whole-body positron emission tomography with computed tomography (WB-PET/CT), and whole-body positron emission tomography with magnetic resonance imaging (WB-PET/MRI) in staging patients with untreated invasive ductal carcinoma of the breast. Fifty-one women with newly diagnosed invasive ductal carcinoma of the breast underwent WB-DWI, WB-PET/CT and WB-PET/MRI before treatment. A radiologist and a nuclear medicine physician reviewed in consensus the images from the three modalities and searched for occurrence, number and location of metastases. Final staging, according to each technique, was compared. Pathology and imaging follow-up were used as the reference. WB-DWI, WB-PET/CT and WB-PET/MRI correctly and concordantly staged 33/51 patients: stage IIA in 7 patients, stage IIB in 8 patients, stage IIIC in 4 patients and stage IV in 14 patients. WB-DWI, WB-PET/CT and WB-PET/MRI incorrectly and concordantly staged 1/51 patient as stage IV instead of IIIA. Discordant staging was reported in 17/51 patients. WB-PET/MRI resulted in improved staging when compared to WB-PET/CT (50 correctly staged on WB-PET/MRI vs. 38 correctly staged on WB-PET/CT; McNemar's test; p<0.01). Comparing the performance of WB-PET/MRI and WB-DWI (43 correct) did not reveal a statistically significant difference (McNemar test, p=0.14). WB-PET/MRI is more accurate in the initial staging of breast cancer than WB-DWI and WB-PET/CT, however, the discrepancies between WB-PET/MRI and WB-DWI were not statistically significant. When available, WB-PET/MRI should be considered for staging patient with invasive ductal breast carcinoma.

  6. Comparison of CT perfusion summary maps to early diffusion-weighted images in suspected acute middle cerebral artery stroke.

    PubMed

    Benson, John; Payabvash, Seyedmehdi; Salazar, Pascal; Jagadeesan, Bharathi; Palmer, Christopher S; Truwit, Charles L; McKinney, Alexander M

    2015-04-01

    To assess the accuracy and reliability of one vendor's (Vital Images, Toshiba Medical, Minnetonka, MN) automated CT perfusion (CTP) summary maps in identification and volume estimation of infarcted tissue in patients with acute middle cerebral artery (MCA) distribution infarcts. From 1085 CTP examinations over 5.5 years, 43 diffusion-weighted imaging (DWI)-positive patients were included who underwent both CTP and DWI <12 h after symptom onset, with another 43 age-matched patients as controls (DWI-negative). Automated delay-corrected postprocessing software (DC-SVD) generated both infarct "core only" and "core+penumbra" CTP summary maps. Three reviewers independently tabulated Alberta Stroke Program Early CT scores (ASPECTS) of both CTP summary maps and coregistered DWI. Of 86 included patients, 36 had DWI infarct volumes ≤70 ml, 7 had volumes >70 ml, and 43 were negative; the automated CTP "core only" map correctly classified each as >70 ml or ≤70 ml, while the "core+penumbra" map misclassified 4 as >70 ml. There were strong correlations between DWI volume with both summary map-based volumes: "core only" (r=0.93), and "core+penumbra" (r=0.77) (both p<0.0001). Agreement between ASPECTS scores of infarct core on DWI with summary maps was 0.65-0.74 for "core only" map, and 0.61-0.65 for "core+penumbra" (both p<0.0001). Using DWI-based ASPECTS scores as the standard, the accuracy of the CTP-based maps were 79.1-86.0% for the "core only" map, and 83.7-88.4% for "core+penumbra." Automated CTP summary maps appear to be relatively accurate in both the detection of acute MCA distribution infarcts, and the discrimination of volumes using a 70 ml threshold. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Preliminary X-ray diffraction analysis of a thermophilic β-1,3-1,4-glucanase from Clostridium thermocellum.

    PubMed

    Zhang, Lilan; Zhao, Puya; Chen, Chun-Chi; Huang, Chun-Hsiang; Ko, Tzu-Ping; Zheng, Yingying; Guo, Rey-Ting

    2014-07-01

    β-1,3-1,4-Glucanases catalyze the specific hydrolysis of internal β-1,4-glycosidic bonds adjacent to the 3-O-substituted glucose residues in mixed-linked β-glucans. The thermophilic glycoside hydrolase CtGlu16A from Clostridium thermocellum exhibits superior thermal profiles, high specific activity and broad pH adaptability. Here, the catalytic domain of CtGlu16A was expressed in Escherichia coli, purified and crystallized in the trigonal space group P3121, with unit-cell parameters a=b=74.5, c=182.9 Å, by the sitting-drop vapour-diffusion method and diffracted to 1.95 Å resolution. The crystal contains two protein molecules in an asymmetric unit. Further structural determination and refinement are in progress.

  8. Numerical Simulation of Chemically Reacting Flows

    DTIC Science & Technology

    2015-09-03

    62 (1986) 1-25. 6. O.L. Burchett, M.R. Birnbaum, and C.T. Oien, “ Compaction studies of palladium/aluminum powder ,” Sandia National Laboratories...interest to the Air Force. 15. SUBJECT TERMS Numerical methods, Diffusion Flames, Adaptive Gridding, Velocity-Vorticity, Compact Methods 16...discussed ab ot require th sure mass c mputational city formula e spectrum soot forma formulation lent agreem ing MC-Sm ork will lik ith compact iled

  9. Characterization of highly hydrophobic textiles by means of X-ray microtomography, wettability analysis and drop impact

    NASA Astrophysics Data System (ADS)

    Santini, M.; Guilizzoni, M.; Fest-Santini, S.; Lorenzi, M.

    2017-11-01

    Highly hydrophobic surfaces have been intensively investigated in the last years because their properties may lead to very promising technological spillovers encompassing both everyday use and high-tech fields. Focusing on textiles, hydrophobic fabrics are of major interest for applications ranging from clothes to architecture to environment protection and energy conversion. Gas diffusion media - made by a gas diffusion layer (GDL) and a microporous layer (MPL) - for fuel cells are a good benchmark to develop techniques aimed at characterizing the wetting performances of engineered textiles. An experimental investigation was carried out about carbon-based, PTFE-treated GDLs with and without MPLs. Two samples (woven and woven-non-woven) were analysed before and after coating with a MPL. Their three-dimensional structure was reconstructed and analysed by computer-aided X-ray microtomography (µCT). Static and dynamic wettability analyses were then carried out using a modified axisymmetric drop shape analysis technique. All the surfaces exhibited very high hydrophobicity, three of them near to a super-hydrophobic behavior. Water drop impacts were performed, evidencing different bouncing, sticking and fragmentation outcomes for which critical values of the Weber number were identified. Finally, a µCT scan of a drop on a GDL was performed, confirming the Cassie-Baxter wetting state on such surface.

  10. [Lung is also involved in juvenile dermatomyositis].

    PubMed

    Pouessel, G; Thumerelle, C; Nève, V; Santangelo, T; Flammarion, S; Pruvot, I; Tillie-Leblond, I; Deschildre, A

    2014-07-01

    Juvenile dermatomyositis is the leading cause of chronic idiopathic inflammatory myopathy of auto-immune origin in children. Lung involvement in inflammatory myopathies is well described in adults, involving mostly interstitial lung disease, aspiration pneumonia and alveolar hypoventilation. We propose to describe its specificities in children. Pulmonary involvement may be asymptomatic and therefore must be systematically screened for. In case of clinical or functional respiratory abnormality, a chest computed tomographic (CT) scan is necessary. In children, a decrease of respiratory muscle strength seems common and should be systematically and specifically searched for by non-invasive and reproducible tests (sniff test). Interstitial lung disease usually associates restrictive functional defect, impairment of carbon monoxide diffusion and interstitial lung disease on CT scan. As in adults, the first-line treatment of juvenile dermatomyositis is based on corticosteroids. Corticosteroid resistant forms require corticosteroid bolus or adjuvant immunosuppressive drugs (methotrexate or cyclosporine). There is no consensus in pediatrics for the treatment of diffuse interstitial lung disease. Complications of treatment, including prolonged steroid therapy, are frequent and therefore a careful assessment of the treatments risk-benefit ratio is necessary, especially in growing children. Copyright © 2014 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  11. Microstructural evolution during sintering of copper particles studied by laboratory diffraction contrast tomography (LabDCT).

    PubMed

    McDonald, S A; Holzner, C; Lauridsen, E M; Reischig, P; Merkle, A P; Withers, P J

    2017-07-12

    Pressureless sintering of loose or compacted granular bodies at elevated temperature occurs by a combination of particle rearrangement, rotation, local deformation and diffusion, and grain growth. Understanding of how each of these processes contributes to the densification of a powder body is still immature. Here we report a fundamental study coupling the crystallographic imaging capability of laboratory diffraction contrast tomography (LabDCT) with conventional computed tomography (CT) in a time-lapse study. We are able to follow and differentiate these processes non-destructively and in three-dimensions during the sintering of a simple copper powder sample at 1050 °C. LabDCT quantifies particle rotation (to <0.05° accuracy) and grain growth while absorption CT simultaneously records the diffusion and deformation-related morphological changes of the sintering particles. We find that the rate of particle rotation is lowest for the more highly coordinated particles and decreases during sintering. Consequently, rotations are greater for surface breaking particles than for more highly coordinated interior ones. Both rolling (cooperative) and sliding particle rotations are observed. By tracking individual grains the grain growth/shrinkage kinetics during sintering are quantified grain by grain for the first time. Rapid, abnormal grain growth is observed for one grain while others either grow or are consumed more gradually.

  12. The value of the identification of predisposing factors for post-traumatic amnesia in management of mild traumatic brain injury.

    PubMed

    Fotakopoulos, George; Makris, Demosthenes; Tsianaka, Eleni; Kotlia, Polikceni; Karakitsios, Paulos; Gatos, Charalabos; Tzannis, Alkiviadis; Fountas, Kostas

    2018-01-01

    To identify the risk factors for post-traumatic amnesia (PTA) and to document the incidence of PTA after mild traumatic brain injuries. This was a prospective study, affecting mild TBI (mTBI) (Glasgow Coma Scale 14-15) cases attending to the Emergency Department between January 2009 and April 2012 (40 months duration). Patients were divided into two groups (Group A: without PTA, and Group B: with PTA, and they were assessed according to the risk factors. A total of 1762 patients (males: 1002, 56.8%) were meeting study inclusion criteria [Group A: n = 1678 (83.8%), Group B: n = 84 (4.2%)]. Age, CT findings: (traumatic focal HCs in the frontal and temporal lobes or more diffuse punctate HCs, and skull base fractures), anticoagulation therapy and seizures were independent factors of PTA. There was no statistically significant correlation between PTA and sex, convexity fractures, stroke event, mechanism of mTBI (fall +/or beating), hypertension, coronary heart disease, chronic smokers and diabetes (p > 0.005). CT findings: (traumatic focal HCs in the frontal and temporal lobes or more diffuse punctate HCs and skull base fractures), age, seizures and anticoagulation/antiplatelet therapy, were independent factors of PTA and could be used as predictive factors after mTBI.

  13. [Cervical abscess by Streptococcus anginosus-milleri after foreign body ingestion and suspicion of esophageal perforation].

    PubMed

    Pino Rivero, V; Trinidad Ramos, G; González Palomino, A; Pantoja Hernández, C G; Mogollón Cano-Cortés, T; Carrasco Claver, F; Guerra Camacho, M; Blasco Huelva, A

    2006-01-01

    We report a case of cervical abscess after the ingestion of foreign body (chicken bone) secondary to probable esophageal perforation that it was sent to us with suspicion of mediastinal complication. The girl, 17 years-old, nothing else to arrive our hospitalary center required entrance in ICU due to her severe clinical process: High fever, intense neck-thoracic pain, laterocervical diffuse and progressive left inflammation and bad general state. The CT showed the presence of a well defined abscess and abundant aerial component that dissected the cervical muscles that made necessary to perform drainage verifying intraoperatively no mediastinal involvement. The culture of the purulent collection revealed Streptococcus anginosus/milleri resistant to clindamicine but sensible to penicilina and derivatives. We exposed a serie of considerations at respect of such microorganism and its clinical signification.

  14. [Hydroxyurea-induced pneumonia].

    PubMed

    Girard, A; Ricordel, C; Poullot, E; Claeyssen, V; Decaux, O; Desrues, B; Delaval, P; Jouneau, S

    2014-05-01

    Hydroxyurea is an antimetabolite drug used in the treatment of myeloproliferative disorders. Common adverse effects include haematological, gastrointestinal cutaneous manifestations, and fever. Hydroxyurea-induced pneumonitis is unusual. A female patient was treated with hydroxyurea for polycythemia vera. She was admitted 20 days after commencing treatment with a high fever, productive cough, clear sputum and nausea. A chest CT-scan showed diffuse ground-glass opacities. Microbiological investigations were negative. The symptoms disappeared a few days after discontinuation of the drug and rechallenge led to a relapse of symptoms. Our case and 15 earlier cases of hydroxyurea-induced pneumonitis are reviewed. Two patterns of this disease may exist: an acute febrile form occurring within 1 month of introduction of hydroxyurea and a subacute form without fever. Even if uncommon, one should be aware of this complication of hydroxyurea. Copyright © 2013. Published by Elsevier Masson SAS.

  15. [It starts as a Lumbovertebral syndrome and ends as an acute confusional state].

    PubMed

    Gianella, Pietro; Fusi, Tanja; Bernasconi, Enos

    2013-12-31

    Here we report the case of a 19-year-old somalian man who has been admitted to our emergency department because of an important lumbago without trauma. The physical examination on arrival showed a diffuse painful percussion of the left paraspinal muscles without neurological impairment. The laboratory exams displayed a significant elevation of the inflammatory response (CRP 154 mg/l, procalcitonin 0,05 µg/l), the blood cultures were negative and a thoracic and lumbar computed tomography (CT) was not conclusive. The unclear clinical picture led to a magnetic resonance imaging, showing the presence of an abscess in the left thoraco-lumbar paraspinal musculature with ongoing invasion of the epidural space. The clinical picture became dramatic as the patient suddenly developed a frank nuchal rigidity associated with an acute confusional state, caused by the rupture of the abscess in the meningeal space with secondary meningitis, confirmed by a lumbar puncture, where S. aureus was found.

  16. Fulminate Hepatic Failure as an Initial Presentation of Non-Hodgkin Lymphoma: A Case Report

    PubMed Central

    Ahmadi, Bizhan; Shafieipour, Sara; Akhavan Rezayat, Kambiz

    2014-01-01

    Viral hepatitis and toxins comprise most common causes of fulminate hepatic failure that are often diagnosed with standard laboratory tests. Herein we discuss a rare, difficult to diagnosis etiology of acute liver failure (ALF). A 62-year-old man presented with a two-week history of fever and fatigue. At four days before admission he became lethargic. His past medical and drug histories were unremarkable. Physical examination revealed generalized jaundice, fever and loss of consciousness. Laboratory tests showed elevated liver transaminases with direct hyper-bilirubinemia. Abdominal ultrasonography and CT scan showed hepatosplenomegaly and para-aortic abdominal lymphadenopathy. A further work-up included liver biopsy. The histopathology and imunohistochemistry was compatible with diffuse large B-cell lymphoma. He underwent high dose glucocorticoid therapy but his condition deteriorated rapidly and he died eight days after admission. ALF as an initial manifestation of malignant hepatic infiltration is extremely rare yet should be considered in all patients with unknown hepatic failure that are highly suspicious for malignant neoplasm. PMID:24872870

  17. An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CT

    NASA Astrophysics Data System (ADS)

    Poludniowski, G.; Evans, P. M.; Hansen, V. N.; Webb, S.

    2009-06-01

    A new method is proposed for scatter-correction of cone-beam CT images. A coarse reconstruction is used in initial iteration steps. Modelling of the x-ray tube spectra and detector response are included in the algorithm. Photon diffusion inside the imaging subject is calculated using the Monte Carlo method. Photon scoring at the detector is calculated using forced detection to a fixed set of node points. The scatter profiles are then obtained by linear interpolation. The algorithm is referred to as the coarse reconstruction and fixed detection (CRFD) technique. Scatter predictions are quantitatively validated against a widely used general-purpose Monte Carlo code: BEAMnrc/EGSnrc (NRCC, Canada). Agreement is excellent. The CRFD algorithm was applied to projection data acquired with a Synergy XVI CBCT unit (Elekta Limited, Crawley, UK), using RANDO and Catphan phantoms (The Phantom Laboratory, Salem NY, USA). The algorithm was shown to be effective in removing scatter-induced artefacts from CBCT images, and took as little as 2 min on a desktop PC. Image uniformity was greatly improved as was CT-number accuracy in reconstructions. This latter improvement was less marked where the expected CT-number of a material was very different to the background material in which it was embedded.

  18. Imaging patterns and focal lesions in fatty liver: a pictorial review.

    PubMed

    Venkatesh, Sudhakar K; Hennedige, Tiffany; Johnson, Geoffrey B; Hough, David M; Fletcher, Joel G

    2017-05-01

    Non-alcoholic fatty liver disease is the most common cause of chronic liver disease and affects nearly one-third of US population. With the increasing trend of obesity in the population, associated fatty change in the liver will be a common feature observed in imaging studies. Fatty liver causes changes in liver parenchyma appearance on imaging modalities including ultrasound, computed tomography (CT), and magnetic resonance imaging (MRI) and may affect the imaging characteristics of focal liver lesions (FLLs). The imaging characteristics of FLLs were classically described in a non-fatty liver. In addition, focal fatty change and focal fat sparing may also simulate FLLs. Knowledge of characteristic patterns of fatty change in the liver (diffuse, geographical, focal, subcapsular, and perivascular) and their impact on the detection and characterization of FLL is therefore important. In general, fatty change may improve detection of FLLs on MRI using fat suppression sequences, but may reduce sensitivity on a single-phase (portal venous) CT and conventional ultrasound. In patients with fatty liver, MRI is generally superior to ultrasound and CT for detection and characterization of FLL. In this pictorial essay, we describe the imaging patterns of fatty change in the liver and its effect on detection and characterization of FLLs on ultrasound, CT, MRI, and PET.

  19. Combined multispectral spatial frequency domain imaging and computed tomography system for intraoperative breast tumor margin assessment

    NASA Astrophysics Data System (ADS)

    McClatchy, D. M.; Rizzo, E. J.; Krishnaswamy, V.; Kanick, S. C.; Wells, W. A.; Paulsen, K. D.; Pogue, B. W.

    2017-02-01

    There is a dire clinical need for surgical margin guidance in breast conserving therapy (BCT). We present a multispectral spatial frequency domain imaging (SFDI) system, spanning the visible and near-infrared (NIR) wavelengths, combined with a shielded X-ray computed tomography (CT) system, designed for intraoperative breast tumor margin assessment. While the CT can provide a volumetric visualization of the tumor core and its spiculations, the co-registered SFDI can provide superficial and quantitative information about localized changes tissue morphology from light scattering parameters. These light scattering parameters include both model-based parameters of sub-diffusive light scattering related to the particle size scale distribution and also textural information of the high spatial frequency reflectance. Because the SFDI and CT components are rigidly fixed, a simple transformation can be used to simultaneously display the SFDI and CT data in the same coordinate system. This is achieved through the Visualization Toolkit (vtk) file format in the open-source Slicer medical imaging software package. In this manuscript, the instrumentation, data processing, and preliminary human specimen data will be presented. The ultimate goal of this work is to evaluate this technology in a prospective clinical trial, and the current limitations and engineering solutions to meet this goal will also be discussed.

  20. Quantitative Assessment of Degenerative Cartilage and Subchondral Bony Lesions in a Preserved Cadaveric Knee: Propagation-Based Phase-Contrast CT Versus Conventional MRI and CT.

    PubMed

    Geith, Tobias; Brun, Emmanuel; Mittone, Alberto; Gasilov, Sergei; Weber, Loriane; Adam-Neumair, Silvia; Bravin, Alberto; Reiser, Maximilian; Coan, Paola; Horng, Annie

    2018-06-01

    The aim of this study was to quantitatively assess hyaline cartilage and subchondral bone conditions in a fully preserved cadaveric human knee joint using high-resolution x-ray propagation-based phase-contrast imaging (PBI) CT and to compare the performance of the new technique with conventional CT and MRI. A cadaveric human knee was examined using an x-ray beam of 60 keV, a detector with a 90-mm 2 FOV, and a pixel size of 46 × 46 μm 2 . PBI CT images were reconstructed with both the filtered back projection algorithm and the equally sloped tomography method. Conventional 3-T MRI and CT were also performed. Measurements of cartilage thickness, cartilage lesions, International Cartilage Repair Society scoring, and detection of subchondral bone changes were evaluated. Visual inspection of the specimen akin to arthroscopy was conducted and served as a standard of reference for lesion detection. Loss of cartilage height was visible on PBI CT and MRI. Quantification of cartilage thickness showed a strong correlation between the two modalities. Cartilage lesions appeared darker than the adjacent cartilage on PBI CT. PBI CT showed similar agreement to MRI for depicting cartilage substance defects or lesions compared with the visual inspection. The assessment of subchondral bone cysts showed moderate to strong agreement between PBI CT and CT. In contrast to the standard clinical methods of MRI and CT, PBI CT is able to simultaneously depict cartilage and bony changes at high resolution. Though still an experimental technique, PBI CT is a promising high-resolution imaging method to evaluate comprehensive changes of osteoarthritic disease in a clinical setting.

  1. Process research of non-CZ silicon material

    NASA Technical Reports Server (NTRS)

    1983-01-01

    High risk, high payoff research areas associated with the Westinghouse process for producing photovoltaic modules using non- CZ sheet material were investigated. All work was performed using dendritic web silicon. The following tasks are discussed and associated technical results are given: (1) determining the technical feasibility of forming front and back junctions in non-CT silicon using dopant techniques; (2) determining the feasibility of forming a liquid applied diffusion mask to replace the more costly chemical vapor deposited SiO2 diffusion mask; (3) determining the feasibility of applying liquid anti-reflective solutions using meniscus coating equipment; (4) studying the production of uniform, high efficiency solar cells using ion implanation junction formation techniques; and (5) quantifying cost improvements associated with process improvements.

  2. Hyperpolarized 3He and 129Xe magnetic resonance imaging apparent diffusion coefficients: physiological relevance in older never‐ and ex‐smokers

    PubMed Central

    Kirby, Miranda; Ouriadov, Alexei; Svenningsen, Sarah; Owrangi, Amir; Wheatley, Andrew; Etemad‐Rezai, Roya; Santyr, Giles E.; McCormack, David G.; Parraga, Grace

    2014-01-01

    Abstract Noble gas pulmonary magnetic resonance imaging (MRI) is transitioning away from 3He to 129Xe gas, but the physiological/clinical relevance of 129Xe apparent diffusion coefficient (ADC) parenchyma measurements is not well understood. Therefore, our objective was to generate 129Xe MRI ADC for comparison with 3He ADC and with well‐established measurements of alveolar structure and function in older never‐smokers and ex‐smokers with chronic obstructive pulmonary disease (COPD). In four never‐smokers and 10 COPD ex‐smokers, 3He (b = 1.6 sec/cm2) and 129Xe (b = 12, 20, and 30 sec/cm2) ADC, computed tomography (CT) density‐threshold measurements, and the diffusing capacity for carbon monoxide (DLCO) were measured. To understand regional differences, the anterior–posterior (APG) and superior–inferior (∆SI) ADC differences were evaluated. Compared to never‐smokers, COPD ex‐smokers showed greater 3He ADC (P = 0.006), 129Xe ADCb12 (P = 0.006), and ADCb20 (P = 0.006), but not for ADCb30 (P > 0.05). Never‐smokers and COPD ex‐smokers had significantly different APG for 3He ADC (P = 0.02), 129Xe ADCb12 (P = 0.006), and ADCb20 (P = 0.01), but not for ADCb30 (P > 0.05). ∆SI for never‐ and ex‐smokers was significantly different for 3He ADC (P = 0.046), but not for 129Xe ADC (P > 0.05). There were strong correlations for DLCO with 3He ADC and 129Xe ADCb12 (both r = −0.95, P < 0.05); in a multivariate model 129Xe ADCb12 was the only significant predictor of DLCO (P = 0.049). For COPD ex‐smokers, CT relative area <−950 HU (RA950) correlated with 3He ADC (r = 0.90, P = 0.008) and 129Xe ADCb12 (r = 0.85, P = 0.03). In conclusion, while 129Xe ADCb30 may be appropriate for evaluating subclinical or mild emphysema, in this small group of never‐smokers and ex‐smokers with moderate‐to‐severe emphysema, 129Xe ADCb12 provided a physiologically appropriate estimate of gas exchange abnormalities and alveolar microstructure. PMID:25347853

  3. Rapid fall in lung density following smoking cessation in COPD.

    PubMed

    Shaker, Saher B; Stavngaard, Trine; Laursen, Lars Christian; Stoel, Berend C; Dirksen, Asger

    2011-02-01

    Whether smoking-induced lung inflammation subsides after smoking cessation is currently a matter of debate. We used computed tomography (CT) to evaluate the effect of smoking cessation on lung density in patients with COPD. Thirty-six patients quit smoking out of 254 current smokers with COPD who were followed with annual CT and lung function tests (LFT) for 2?4 years as part of a randomised placebo-controlled trial of the effect of inhaled budesonide on CT-lung density. Lung density was expressed as the 15th percentile density (PD15) and relative area of emphysema below -910 HU (RA-910). From the time-trends in the budesonide and placebo groups the expected CT-lung densities at the first visit after smoking cessation were calculated by linear regression and compared to the observed densities. Following smoking cessation RA-910 increased by 2.6% (p = 0.003) and PD15 decreased by -4.9 HU (p = 0.0002). Furthermore, changes were larger in the budesonide group than the placebo group (PD15: -7.1 vs -2.8 HU. RA-910 3.7% vs 1.7%). These differences were, however, not statistically significant. The LFT parameters (FEV(1) and diffusion capacity) were not significantly influenced by smoking cessation. Inflammation partly masks the presence of emphysema on CT and smoking cessation results in a paradoxical fall in lung density, which resembles rapid progression of emphysema. This fall in density is probably due to an anti-inflammatory effect of smoking cessation.

  4. [Preoperative CT Scan in middle ear cholesteatoma].

    PubMed

    Sethom, Anissa; Akkari, Khemaies; Dridi, Inès; Tmimi, S; Mardassi, Ali; Benzarti, Sonia; Miled, Imed; Chebbi, Mohamed Kamel

    2011-03-01

    To compare preoperative CT scan finding and per-operative lesions in patients operated for middle ear cholesteatoma, A retrospective study including 60 patients with cholesteatoma otitis diagnosed and treated within a period of 5 years, from 2001 to 2005, at ENT department of Military Hospital of Tunis. All patients had computed tomography of the middle and inner ear. High resolution CT scan imaging was performed using millimetric incidences (3 to 5 millimetres). All patients had surgical removal of their cholesteatoma using down wall technic. We evaluated sensitivity, specificity and predictive value of CT-scan comparing otitic damages and CT finding, in order to examine the real contribution of computed tomography in cholesteatoma otitis. CT scan analysis of middle ear bone structures shows satisfaction (with 83% of sensibility). The rate of sensibility decrease (63%) for the tympanic raff. Predictive value of CT scan for the diagnosis of cholesteatoma was low. However, we have noticed an excellent sensibility in the analysis of ossicular damages (90%). Comparative frontal incidence seems to be less sensible for the detection of facial nerve lesions (42%). But when evident on CT scan findings, lesions of facial nerve were usually observed preoperatively (spécificity 78%). Predictive value of computed tomography for the diagnosis of perilymphatic fistulae (FL) was low. In fact, CT scan imaging have showed FL only for four patients among eight. Best results can be obtained if using inframillimetric incidences with performed high resolution computed tomography. Preoperative computed tomography is necessary for the diagnosis and the evaluation of chronic middle ear cholesteatoma in order to show extending lesion and to detect complications. This CT analysis and surgical correlation have showed that sensibility, specificity and predictive value of CT-scan depend on the anatomic structure implicated in cholesteatoma damages.

  5. Insulinoma presenting as idiopathic hypersomnia.

    PubMed

    Maestri, Michelangelo; Monzani, Fabio; Bonanni, Enrica; Di Coscio, Elisa; Cignoni, Fabio; Dardano, Angela; Iudice, Alfonso; Murri, Luigi

    2010-06-01

    We report the case of a 32-year-old woman with a history of increased sleep need and difficulty waking up; the diagnosis of idiopathic hypersomnia was hypothesized. During ambulatory polysomnography (PSG), the patient presented an episode characterized by loss of consciousness and jerking of the four limbs. A video-PSG monitoring was performed and the patient showed unresponsiveness and drowsiness at 7 a.m. During the episode, EEG showed theta-delta diffuse activity, and blood glucose level was 32 mg dl(-1). The diagnosis of insulinoma was then assumed; CT scan showed a hypodense mass into the pancreatic tail, and a partial pancreasectomy was performed. The described symptoms disappeared, and 5 years later the findings of a complete clinical and neurophysiological examination were negative. The clinical picture of insulinoma presenting with paroxysmal disorders has been previously described; however, whereas hypersomnia is uncommon, in the current case it represents the main symptom. Clinicians should keep in mind that neuroglycopenia should be considered in the differential diagnosis of patients with hypersomnia, particularly if the clinical scenario does not conform to standard criteria.

  6. Acute cerebellitis successfully managed with temporary cerebrospinal fluid diversion using a long tunnel external ventricular drain: a long-term radiological follow-up of two cases

    PubMed Central

    Waqas, Muhammad; Hadi, Yousaf Bashir; Sheikh, Sadaf; Shamim, Shahzad M

    2016-01-01

    Acute cerebellitis (AC) is a rare inflammatory childhood disorder. Although there is no consensus on standard treatment for cerebellitis, its outcome is usually favourable. We report two cases of AC in the paediatric age group, successfully managed with long tunnel external ventricular drain (EVD). The first patient was an 8-year-old boy with a history of fever and headache. Sequential MRI showed diffuse cerebellar swelling with tonsillar herniation and resulting hydrocephalus. The second patient was a 6-month-old boy who presented with high-grade fever associated with chills. CT scan of the head showed triventricular hydrocephalus with obliteration of cerebrospinal fluid spaces and cisterns. Both patients underwent immediate emergency right-sided long tunnel EVD insertion. The EVD was removed on the 9th day in the first patient and the 10th day in the second patient; the patients showed no neurological deficits at a follow-up of 2 years and 1 year, respectively. PMID:27166004

  7. Theoretical examination of effective oxygen diffusion coefficient and electrical conductivity of polymer electrolyte fuel cell porous components

    NASA Astrophysics Data System (ADS)

    Inoue, Gen; Yokoyama, Kouji; Ooyama, Junpei; Terao, Takeshi; Tokunaga, Tomomi; Kubo, Norio; Kawase, Motoaki

    2016-09-01

    The reduction of oxygen transfer resistance through porous components consisting of a gas diffusion layer (GDL), microporous layer (MPL), and catalyst layer (CL) is very important to reduce the cost and improve the performance of a PEFC system. This study involves a systematic examination of the relationship between the oxygen transfer resistance of the actual porous components and their three-dimensional structure by direct measurement with FIB-SEM and X-ray CT. Numerical simulations were carried out to model the properties of oxygen transport. Moreover, based on the model structure and theoretical equations, an approach to the design of new structures is proposed. In the case of the GDL, the binder was found to obstruct gas diffusion with a negative effect on performance. The relative diffusion coefficient of the MPL is almost equal to that of the model structure of particle packing. However, that of CL is an order of magnitude less than those of the other two components. Furthermore, an equation expressing the relative diffusion coefficient of each component can be obtained with the function of porosity. The electrical conductivity of MPL, which is lower than that of the carbon black packing, is considered to depend on the contact resistance.

  8. Uptake of 18F-DCFPyL in Paget's Disease of Bone, an Important Potential Pitfall in Clinical Interpretation of PSMA PET Studies.

    PubMed

    Rowe, Steven P; Deville, Curtiland; Paller, Channing; Cho, Steve Y; Fishman, Elliot K; Pomper, Martin G; Ross, Ashley E; Gorin, Michael A

    2015-12-01

    Prostate-specific membrane antigen (PSMA)-targeted PET imaging is an emerging technique for evaluating patients with prostate cancer (PCa) in a variety of clinical contexts. As with any new imaging modality, there are interpretive pitfalls that are beginning to be recognized. In this image report, we describe the findings in a 63-year-old male with biochemically recurrent PCa after radical prostatectomy who was imaged with 18 F-DCFPyL, a small molecule inhibitor of PSMA. Diffuse radiotracer uptake was noted throughout the sacrum, corresponding to imaging findings on contrast-enhanced CT, bone scan, and pelvic MRI consistent with Paget's disease of bone. The uptake of 18 F-DCFPyL in Paget's disease is most likely due to hyperemia and increased radiotracer delivery. In light of the overlap in patients affected by PCa and Paget's, it is important for nuclear medicine physicians and radiologists interpreting PSMA PET/CT scans to be aware of the potential for this diagnostic pitfall. Correlation to findings on conventional imaging such as diagnostic CT and bone scan can help confirm the diagnosis.

  9. Chronic Granulomatous Disease Presenting as Aspergillus Fumigatus Pneumonia in a Previously Healthy Young Woman.

    PubMed

    Williams, David; Kadaria, Dipen; Sodhi, Amik; Fox, Roy; Williams, Glenn; Threlkeld, Stephen

    2017-04-05

    BACKGROUND Chronic Granulomatous Disease (CGD) is a rare immunodeficiency disease caused by a genetic defect in the NADPH (nicotinamide adenine dinucleotide phosphate) oxidase enzyme, resulting in increased susceptibility to bacterial and fungal infections. The inheritance can be X-linked or autosomal recessive. Patients usually present with repeated infections early in life. We present an unusual case of a 23-year-old patient diagnosed with CGD. CASE REPORT A 23-year-old white woman with no previous history of recurrent infections presented with complaints of fever, shortness of breath, and diffuse myalgia. She had been treated twice for similar complaints recently, but without resolution. She was febrile, tachypneic, tachycardic, and hypoxic at presentation. Physical examination revealed diffuse inspiratory rales. Laboratory results showed leukocytosis. Her initial chest X-ray and CT chest showed reticular nodular interstitial lung disease pattern. Despite being on broad-spectrum antibiotics for 5 days, she continued to require supplemental oxygen and continued to be tachypneic, with minimal activity. Initial diagnostic tests, including bronchoscopy with biopsy and lavage, did not reveal a diagnosis. She then underwent a video-assisted thoracoscopic surgery (VATS) lung biopsy. The biopsy slides showed suppurative granulomatous inflammation affecting greater than 50% of the parenchymal lung surface. Fungal hyphae consistent with Aspergillus were present in those granulomas. A diagnosis of CGD was made and she was started on Voriconazole. She improved with treatment. Her neutrophil burst test showed negative burst on stimulation, indicating phagocytic dysfunction consistent with CGD. Autosomal recessive CGD was confirmed by genetic testing. CONCLUSIONS CGD can present in adulthood without any previous symptoms and signs. Clinicians should consider this disease in patients presenting with recurrent or non-resolving infections. Timely treatment and prophylaxis has been shown to reduce serious infections as well as mortality in these patients.

  10. Charge versus Energy Transfer Effects in High-Performance Perylene Diimide Photovoltaic Blend Films.

    PubMed

    Singh, Ranbir; Shivanna, Ravichandran; Iosifidis, Agathaggelos; Butt, Hans-Jürgen; Floudas, George; Narayan, K S; Keivanidis, Panagiotis E

    2015-11-11

    Perylene diimide (PDI)-based organic photovoltaic devices can potentially deliver high power conversion efficiency values provided the photon energy absorbed is utilized efficiently in charge transfer (CT) reactions instead of being consumed in nonradiative energy transfer (ET) steps. Hitherto, it remains unclear whether ET or CT primarily drives the photoluminescence (PL) quenching of the PDI excimer state in PDI-based blend films. Here, we affirm the key role of the thermally assisted PDI excimer diffusion and subsequent CT reaction in the process of PDI excimer PL deactivation. For our study we perform PL quenching experiments in the model PDI-based composite made of poly[4,8-bis(5-(2-ethylhexyl)thiophen-2-yl)benzo[1,2-b;4,5-b']dithiophene-2,6-diyl-alt-(4-(2-ethylhexanoyl)-thieno[3,4-b]thiophene)-2-6-diyl] (PBDTTT-CT) polymeric donor mixed with the N,N'-bis(1-ethylpropyl)-perylene-3,4,9,10-tetracarboxylic diimide (PDI) acceptor. Despite the strong spectral overlap between the PDI excimer PL emission and UV-vis absorption of PBDTTT-CT, two main observations indicate that no significant ET component operates in the overall PL quenching: the PL intensity of the PDI excimer (i) increases with decreasing temperature and (ii) remains unaffected even in the presence of 10 wt % content of the PBDTTT-CT quencher. Temperature-dependent wide-angle X-ray scattering experiments further indicate that nonradiative resonance ET is highly improbable due to the large size of PDI domains. The dominance of the CT over the ET process is verified by the high performance of devices with an optimum composition of 30:70 PBDTTT-CT:PDI. By adding 0.4 vol % of 1,8-diiodooctane we verify the plasticization of the polymer side chains that balances the charge transport properties of the PBDTTT-CT:PDI composite and results in additional improvement in the device efficiency. The temperature-dependent spectral width of the PDI excimer PL band suggests the presence of energetic disorder in the PDI excimer excited state manifold.

  11. Convergence of Cortical, Thalamocortical, and Callosal Pathways during Human Fetal Development Revealed by Diffusion MRI Tractography.

    PubMed

    Wang, Rongpin; Wilkinson, Molly; Kane, Tara; Takahashi, Emi

    2017-01-01

    There has been evidence that during brain development, emerging thalamocortical (TC) and corticothalamic (CT) pathways converge in some brain regions and follow each other's trajectories to their final destinations. Corpus callosal (CC) pathways also emerge at a similar developmental stage, and are known to converge with TC pathways in specific cortical regions in mature brains. Given the functional relationships between TC and CC pathways, anatomical convergence of the two pathways are likely important for their functional integration. However, it is unknown (1) where TC and CT subcortically converge in the human brain, and (2) where TC and CC converge in the cortex of the human brain, due to the limitations of non-invasive methods. The goals of this study were to describe the spatio-temporal relationships in the development of the TC/CT and CC pathways in the human brain, using high-angular resolution diffusion MR imaging (HARDI) tractography. Emerging cortical, TC and CC pathways were identified in postmortem fetal brains ranging from 17 gestational weeks (GW) to 30 GW, as well as in vivo 34-40 GW newborns. Some pathways from the thalami were found to be converged with pathways from the cerebral cortex as early as 17 GW. Such convergence was observed mainly in anterior and middle regions of the brain until 21 GW. At 22 GW and onwards, posterior pathways from the thalami also converged with cortical pathways. Many CC pathways reached the full length up to the cortical surface as early as 17 GW, while pathways linked to thalami (not only TC axons but also including pathways linked to thalamic neuronal migration) reached the cortical surface at and after 20 GW. These results suggest that CC pathways developed earlier than the TC pathways. The two pathways were widespread at early stages, but by 40 GW they condensed and formed groups of pathways that projected to specific regions of the cortex and overlapped in some brain regions. These results suggest that HARDI tractography has the potential to identify developing TC/CT and CC pathways with the timing and location of their convergence in fetal stages persisting in postnatal development.

  12. Convergence of Cortical, Thalamocortical, and Callosal Pathways during Human Fetal Development Revealed by Diffusion MRI Tractography

    PubMed Central

    Wang, Rongpin; Wilkinson, Molly; Kane, Tara; Takahashi, Emi

    2017-01-01

    There has been evidence that during brain development, emerging thalamocortical (TC) and corticothalamic (CT) pathways converge in some brain regions and follow each other's trajectories to their final destinations. Corpus callosal (CC) pathways also emerge at a similar developmental stage, and are known to converge with TC pathways in specific cortical regions in mature brains. Given the functional relationships between TC and CC pathways, anatomical convergence of the two pathways are likely important for their functional integration. However, it is unknown (1) where TC and CT subcortically converge in the human brain, and (2) where TC and CC converge in the cortex of the human brain, due to the limitations of non-invasive methods. The goals of this study were to describe the spatio-temporal relationships in the development of the TC/CT and CC pathways in the human brain, using high-angular resolution diffusion MR imaging (HARDI) tractography. Emerging cortical, TC and CC pathways were identified in postmortem fetal brains ranging from 17 gestational weeks (GW) to 30 GW, as well as in vivo 34–40 GW newborns. Some pathways from the thalami were found to be converged with pathways from the cerebral cortex as early as 17 GW. Such convergence was observed mainly in anterior and middle regions of the brain until 21 GW. At 22 GW and onwards, posterior pathways from the thalami also converged with cortical pathways. Many CC pathways reached the full length up to the cortical surface as early as 17 GW, while pathways linked to thalami (not only TC axons but also including pathways linked to thalamic neuronal migration) reached the cortical surface at and after 20 GW. These results suggest that CC pathways developed earlier than the TC pathways. The two pathways were widespread at early stages, but by 40 GW they condensed and formed groups of pathways that projected to specific regions of the cortex and overlapped in some brain regions. These results suggest that HARDI tractography has the potential to identify developing TC/CT and CC pathways with the timing and location of their convergence in fetal stages persisting in postnatal development. PMID:29163000

  13. Dose evaluation of an NIPAM polymer gel dosimeter using gamma index

    NASA Astrophysics Data System (ADS)

    Chang, Yuan-Jen; Lin, Jing-Quan; Hsieh, Bor-Tsung; Yao, Chun-Hsu; Chen, Chin-Hsing

    2014-11-01

    An N-isopropylacrylamide (NIPAM) polymer gel dosimeter has great potential in clinical applications. However, its three-dimensional dose distribution must be assessed. In this work, a quantitative evaluation of dose distributions was performed to evaluate the NIPAM polymer gel dosimeter using gamma analysis. A cylindrical acrylic phantom filled with NIPAM gel measuring 10 cm (diameter) by 10 cm (height) by 3 mm (thickness) was irradiated by a 4×4 cm2 square light field. The irradiated gel phantom was scanned using an optical computed tomography (optical CT) scanner (OCTOPUS™, MGS Research, Inc., Madison, CT, USA) at 1 mm resolution. The projection data were transferred to an image reconstruction program, which was written using MATLAB (The MathWorks, Natick, MA, USA). The program reconstructed the image of the optical density distribution using the algorithm of a filter back-projection. Three batches of replicated gel phantoms were independently measured. The average uncertainty of the measurements was less than 1%. The gel was found to have a high degree of spatial uniformity throughout the dosimeter and good temporal stability. A comparison of the line profiles of the treatment planning system and of the data measured by optical CT showed that the dose was overestimated in the penumbra region because of two factors. The first is light scattering due to changes in the refractive index at the edge of the irradiated field. The second is the edge enhancement caused by free radical diffusion. However, the effect of edge enhancement on the NIPAM gel dosimeter is not as significant as that on the BANG gel dosimeter. Moreover, the dose uncertainty is affected by the inaccuracy of the gel container positioning process. To reduce the uncertainty of 3D dose distribution, improvements in the gel container holder must be developed.

  14. Vomeronasal and Olfactory Structures in Bats Revealed by DiceCT Clarify Genetic Evidence of Function

    PubMed Central

    Yohe, Laurel R.; Hoffmann, Simone; Curtis, Abigail

    2018-01-01

    The degree to which molecular and morphological loss of function occurs synchronously during the vestigialization of traits is not well understood. The mammalian vomeronasal system, a sense critical for mediating many social and reproductive behaviors, is highly conserved across mammals. New World Leaf-nosed bats (Phyllostomidae) are under strong selection to maintain a functional vomeronasal system such that most phyllostomids possess a distinct vomeronasal organ and an intact TRPC2, a gene encoding a protein primarily involved in vomeronasal sensory neuron signal transduction. Recent genetic evidence, however, shows that TRPC2 is a pseudogene in some Caribbean nectarivorous phyllostomids. The loss-of-function mutations suggest the sensory neural tissue of the vomeronasal organ is absent in these species despite strong selection on this gene in its mainland relatives, but the anatomy was unknown in most Caribbean nectarivorous phyllostomids until this study. We used diffusible iodine-based contrast-enhanced computed tomography (diceCT) to test whether the vomeronasal and main olfactory anatomy of several phyllostomid species matched genetic evidence of function, providing insight into whether loss of a structure is linked to pseudogenization of a molecular component of the system. The vomeronasal organ is indeed rudimentary or absent in species with a disrupted TRPC2 gene. Caribbean nectar-feeders also exhibit derived olfactory turbinal morphology and a large olfactory recess that differs from closely related bats that have an intact vomeronasal organ, which may hint that the main olfactory system may compensate for loss. We emphasize non-invasive diceCT is capable of detecting the vomeronasal organ, providing a feasible approach for quantifying mammalian chemosensory anatomy across species. PMID:29867373

  15. Altered Cortical Thickness and Tract Integrity of the Mirror Neuron System and Associated Social Communication in Autism Spectrum Disorder.

    PubMed

    Chien, Hsiang-Yun; Gau, Susan Shur-Fen; Hsu, Yung-Chin; Chen, Yu-Jen; Lo, Yu-Chun; Shih, Yao-Chia; Tseng, Wen-Yih Isaac

    2015-12-01

    Previous studies using neural activity recording and neuroimaging techniques have reported functional deficits in the mirror neuron system (MNS) for individuals with autism spectrum disorder (ASD). However, a few studies focusing on gray and white matter structures of the MNS have yielded inconsistent results. The current study recruited adolescents and young adults with ASD (aged 15-26 years) and age-matched typically developing (TD) controls (aged 14-25 years). The cortical thickness (CT) and microstructural integrity of the tracts connecting the regions forming the classical MNS were investigated. High-resolution T1-weighted imaging and diffusion spectrum imaging were performed to quantify the CT and tract integrity, respectively. The structural covariance of the CT of the MNS regions revealed a weaker coordination of the MNS network in ASD. A strong correlation was found between the integrity of the right frontoparietal tracts and the social communication subscores measured by the Chinese version of the Social Communication Questionnaire. The results showed that there were no significant mean differences in the CTs and tract integrity between the ASD and TD groups, but revealed a moderate or even reverse age effect on the frontal MNS structures in ASD. In conclusion, aberrant structural coordination may be an underlying factor affecting the function of the MNS in ASD patients. The association between the right frontoparietal tracts and social communication performance implies a neural correlate of communication processing in the autistic brain. This study provides evidence of abnormal MNS structures and their influence on social communication in individuals with ASD. © 2015 International Society for Autism Research, Wiley Periodicals, Inc.

  16. Quantitative computed tomography of lung parenchyma in patients with emphysema: analysis of higher-density lung regions

    NASA Astrophysics Data System (ADS)

    Lederman, Dror; Leader, Joseph K.; Zheng, Bin; Sciurba, Frank C.; Tan, Jun; Gur, David

    2011-03-01

    Quantitative computed tomography (CT) has been widely used to detect and evaluate the presence (or absence) of emphysema applying the density masks at specific thresholds, e.g., -910 or -950 Hounsfield Unit (HU). However, it has also been observed that subjects with similar density-mask based emphysema scores could have varying lung function, possibly indicating differences of disease severity. To assess this possible discrepancy, we investigated whether density distribution of "viable" lung parenchyma regions with pixel values > -910 HU correlates with lung function. A dataset of 38 subjects, who underwent both pulmonary function testing and CT examinations in a COPD SCCOR study, was assembled. After the lung regions depicted on CT images were automatically segmented by a computerized scheme, we systematically divided the lung parenchyma into different density groups (bins) and computed a number of statistical features (i.e., mean, standard deviation (STD), skewness of the pixel value distributions) in these density bins. We then analyzed the correlations between each feature and lung function. The correlation between diffusion lung capacity (DLCO) and STD of pixel values in the bin of -910HU <= PV < -750HU was -0.43, as compared with a correlation of -0.49 obtained between the post-bronchodilator ratio (FEV1/FVC) measured by the forced expiratory volume in 1 second (FEV1) dividing the forced vital capacity (FVC) and the STD of pixel values in the bin of -1024HU <= PV < -910HU. The results showed an association between the distribution of pixel values in "viable" lung parenchyma and lung function, which indicates that similar to the conventional density mask method, the pixel value distribution features in "viable" lung parenchyma areas may also provide clinically useful information to improve assessments of lung disease severity as measured by lung functional tests.

  17. Acute bithalamic infarct manifesting as sleep-like coma: A diagnostic challenge.

    PubMed

    Honig, Asaf; Eliahou, Ruth; Eichel, Roni; Shemesh, Ari Aharon; Ben-Hur, Tamir; Auriel, Eitan

    2016-12-01

    Bilateral thalamic infarction (BTI) typically presents as a sleep-like coma (SLC) without localizing signs, posing a diagnostic challenge that may lead the treating physician to search for toxic or metabolic causes and delay treatment. We review our experience with BTI of different etiologies, and emphasize the critical role of timely imaging, diagnosis, and management in a series of 12 patients with a presentation of SLC and acute BTI who were managed in our Medical Centers from 2006-2015. In 11/12, urgent head CT scans showed normal brain tissue, while diffusion-weighted (DWI) MRI revealed symmetric bilateral thalamic hyperintense lesions with variable degrees of brainstem involvement. In 1/12, CT scans revealed a contralateral subacute stroke from a thalamic infarct 1month earlier with a unilateral hyperintense lesion on DWI-MRI. From clinical and imaging findings (DWI-MRI, CT angiography and venography), etiology was attributed to embolic causes (cardio-embolism, artery-to-artery mechanism), small vessel disease, or deep sinus vein thrombosis secondary to dural arteriovenous (AV) fistula. Three patients had good outcomes after prompt diagnosis and optimal treatment in <3hours (intravenous tissue plasminogen activator in two patients cardio-embolic etiology and neuro-endovascular repair in one patient with venous infarction due to a dural AV fistula). The diagnosis was made beyond the therapeutic window in seven patients, who were left with significant neurological sequelae. Higher awareness of BTI presenting as SLC is warranted. Optimal patient management includes urgent DWI-MRI. In cases of BTI, further imaging workup is indicated to provide a comprehensive assessment for etiology. Early diagnosis and prompt, targeted intervention are crucial. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Evidence of yttrium silicate inclusions in YSZ-porcelain veneers.

    PubMed

    Stoner, Brian R; Griggs, Jason A; Neidigh, John; Piascik, Jeffrey R

    2014-04-01

    This report introduces the discovery of crystalline defects that can form in the porcelain veneering layer when in contact with yttria-stabilized zirconia (YSZ). The focus was on dental prostheses and understanding the defects that form in the YSZ/porcelain system; however the data reported herein may have broader implications toward the use and stability of YSZ-based ceramics in general. Specimens were cut from fully sintered YSZ plates and veneering porcelain was applied (<1 mm thick) to one surface and fired under manufacturer's recommended protocol. Scanning electron microscopy (SEM) with integrated electron dispersive X-ray (EDAX) was used for microstructural and elemental analysis. EDAX, for chemical analysis and transmission electron diffraction (TED) for structural analysis were both performed in the transmission electron microscope (TEM). Additionally, in order to spatially resolve Y-rich precipitates, micro-CT scans were conducted at varying depths within the porcelain veneer. Local EDAX (SEM) was performed in the regions of visible inclusions and showed significant increases in yttrium concentration. TEM specimens also showed apparent inclusions in the porcelain and selected area electron diffraction was performed on these regions and found the inclusions to be crystalline and identified as either yttrium-silicate (Y2 SiO5 ) or yttrium-disilicate (Y2 Si2 O7 ). Micro-CT data showed that yttrium-silicate precipitates were distributed throughout the thickness of the porcelain veneer. Future studies are needed to determine whether many of the premature failures associated with this materials system may be the result of crystalline flaws that form as a result of high temperature yttrium diffusion near the surfaces of YSZ. © 2013 Wiley Periodicals, Inc.

  19. Deep neural network convolution (NNC) for three-class classification of diffuse lung disease opacities in high-resolution CT (HRCT): consolidation, ground-glass opacity (GGO), and normal opacity

    NASA Astrophysics Data System (ADS)

    Hashimoto, Noriaki; Suzuki, Kenji; Liu, Junchi; Hirano, Yasushi; MacMahon, Heber; Kido, Shoji

    2018-02-01

    Consolidation and ground-glass opacity (GGO) are two major types of opacities associated with diffuse lung diseases. Accurate detection and classification of such opacities are crucially important in the diagnosis of lung diseases, but the process is subjective, and suffers from interobserver variability. Our study purpose was to develop a deep neural network convolution (NNC) system for distinguishing among consolidation, GGO, and normal lung tissue in high-resolution CT (HRCT). We developed ensemble of two deep NNC models, each of which was composed of neural network regression (NNR) with an input layer, a convolution layer, a fully-connected hidden layer, and a fully-connected output layer followed by a thresholding layer. The output layer of each NNC provided a map for the likelihood of being each corresponding lung opacity of interest. The two NNC models in the ensemble were connected in a class-selection layer. We trained our NNC ensemble with pairs of input 2D axial slices and "teaching" probability maps for the corresponding lung opacity, which were obtained by combining three radiologists' annotations. We randomly selected 10 and 40 slices from HRCT scans of 172 patients for each class as a training and test set, respectively. Our NNC ensemble achieved an area under the receiver-operating-characteristic (ROC) curve (AUC) of 0.981 and 0.958 in distinction of consolidation and GGO, respectively, from normal opacity, yielding a classification accuracy of 93.3% among 3 classes. Thus, our deep-NNC-based system for classifying diffuse lung diseases achieved high accuracies for classification of consolidation, GGO, and normal opacity.

  20. Neuroimaging findings in children with retinopathy-confirmed cerebral malaria.

    PubMed

    Potchen, Michael J; Birbeck, Gretchen L; Demarco, J Kevin; Kampondeni, Sam D; Beare, Nicholas; Molyneux, Malcolm E; Taylor, Terrie E

    2010-04-01

    To describe brain CT findings in retinopathy-confirmed, paediatric cerebral malaria. In this outcomes study of paediatric cerebral malaria, a subset of children with protracted coma during initial presentation was scanned acutely. Survivors experiencing adverse neurological outcomes also underwent a head CT. All children had ophthalmological examination to confirm the presence of the retinopathy specific for cerebral malaria. Independent interpretation of CT images was provided by two neuroradiologists. Acute brain CT findings in three children included diffuse oedema with obstructive hydrocephalus (2), acute cerebral infarctions in multiple large vessel distributions with secondary oedema and herniation (1), and oedema of thalamic grey matter (1). One child who was reportedly normal prior to admission had parenchymal atrophy suggestive of pre-existing CNS injury. Among 56 survivors (9-84 months old), 15 had adverse neurologic outcomes-11/15 had a follow-up head CT, 3/15 died and 1/15 refused CT. Follow-up head CTs obtained 7-18 months after the acute infection revealed focal and multifocal lobar atrophy correlating to regions affected by focal seizures during the acute infection (5/11). Other findings were communicating hydrocephalus (2/11), vermian atrophy (1/11) and normal studies (3/11). The identification of pre-existing imaging abnormalities in acute cerebral malaria suggests that population-based studies are required to establish the rate and nature of incidental imaging abnormalities in Malawi. Children with focal seizures during acute cerebral malaria developed focal cortical atrophy in these regions at follow-up. Longitudinal studies are needed to further elucidate mechanisms of CNS injury and death in this common fatal disease. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Correlation of B-Lines on Ultrasonography With Interstitial Lung Disease on Chest Radiography and CT Imaging.

    PubMed

    Dubinsky, Theodore J; Shah, Hardik; Sonneborn, Rachelle; Hippe, Daniel S

    2017-11-01

    We prospectively identified B-lines in patients undergoing ultrasonographic (US) examinations following liver transplantation who also had chest radiography (CXR) or chest CT imaging, or both, on the same day to determine if an association between the presence of B-lines from the thorax on US images correlates with the presence of lung abnormalities on CXR. Following institutional review board (IRB) approval, patients who received liver transplants and underwent routine US examinations and chest radiography or CT imaging, or both, on the same day between January 1, 2015 through July 1, 2016 were prospectively identified. Two readers who were blinded to chest films and CT images and reports independently reviewed the US interreader agreement for the presence or absence of B-lines and performed an evaluation for the presence or absence of diffuse parenchymal lung disease (DPLD) on chest films and CT images as well as from clinical evaluation. Receiver operating characteristic (ROC) curves were constructed. There was good agreement between the two readers on the presence of absence of B-lines (kappa = 0.94). The area under the ROC curve for discriminating between positive DPLD and negative DPLD for both readers was 0.79 (95% CI, 0.71-0.87). There is an association between the presence of extensive B-lines to the point of confluence and "dirty shadowing" on US examinations of the chest and associated findings on chest radiographs and CT scans of DPLD. Conversely, isolated B-lines do not always correlate with abnormalities on chest films and in fact sometimes appear to be a normal variant. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  2. Pulmonary emphysema subtypes on computed tomography: the MESA COPD study.

    PubMed

    Smith, Benjamin M; Austin, John H M; Newell, John D; D'Souza, Belinda M; Rozenshtein, Anna; Hoffman, Eric A; Ahmed, Firas; Barr, R Graham

    2014-01-01

    Pulmonary emphysema is divided into 3 major subtypes at autopsy: centrilobular, paraseptal, and panlobular emphysema. These subtypes can be defined by visual assessment on computed tomography (CT); however, clinical characteristics of emphysema subtypes on CT are not well defined. We developed a reliable approach to visual assessment of emphysema subtypes on CT and examined if emphysema subtypes have distinct characteristics. The Multi-Ethnic Study of Atherosclerosis COPD Study recruited smokers with chronic obstructive pulmonary disease (COPD) and controls ages 50-79 years with ≥ 10 pack-years. Participants underwent CT following a standardized protocol. Definitions of centrilobular, paraseptal, and panlobular emphysema were obtained by literature review. Six-minute walk distance and pulmonary function were performed following guidelines. Twenty-seven percent of 318 smokers had emphysema on CT. Interrater reliability of emphysema subtype was substantial (K: 0.70). Compared with participants without emphysema, individuals with centrilobular or panlobular emphysema had greater dyspnea, reduced walk distance, greater hyperinflation, and lower diffusing capacity. In contrast, individuals with paraseptal emphysema were similar to controls, except for male predominance. Centrilobular, but not panlobular or paraseptal, emphysema was associated with greater smoking history (+21 pack-years P <.001). Panlobular, but not other types of emphysema, was associated with reduced body mass index (-5 kg/m(2); P = .01). Other than for dyspnea, these findings were independent of the forced expiratory volume in 1 second. Seventeen percent of smokers without COPD on spirometry had emphysema, which was independently associated with reduced walk distance. Emphysema subtypes on CT are common in smokers with and without COPD. Centrilobular and panlobular emphysema, but not paraseptal emphysema, have considerable symptomatic and physiological consequences. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Pulmonary Emphysema Subtypes on Computed Tomography in Smokers

    PubMed Central

    Smith, Benjamin M.; Austin, John H.M.; Newell, John D.; D’Souza, Belinda M.; Rozenshtein, Anna; Hoffman, Eric A.; Ahmed, Firas; Barr, R. Graham

    2013-01-01

    Background Pulmonary emphysema is divided into three major subtypes at autopsy: centrilobular, paraseptal and panlobular emphysema. These subtypes can be defined by visual assessment on computed tomography (CT); however, clinical characteristics of emphysema subtypes on CT are not well-defined. We developed a reliable approach to visual assessment of emphysema subtypes on CT and examined if emphysema subtypes have distinct characteristics. Methods The Multi-Ethnic Study of Atherosclerosis COPD Study recruited smokers with COPD and controls age 50–79 years with ≥10 pack-years. Participants underwent CT following a standardized protocol. Definitions of centrilobular, paraseptal and panlobular emphysema were obtained by literature review. Six-minute walk distance and pulmonary function were performed following guidelines. Results Twenty-seven percent of 318 smokers had emphysema on CT. Inter-rater reliability of emphysema subtype was substantial (K:0.70). Compared to participants without emphysema, individuals with centrilobular or panlobular emphysema had greater dyspnea, reduced walk distance, greater hyperinflation, and lower diffusing capacity. In contrast, individuals with PSE were similar to controls, except for male predominance. Centrilobular but not panlobular or paraseptal emphysema was associated with greater smoking history (+21 pack-years P<0.001). Panlobular but not other types of emphysema was associated with reduced body mass index (−5 kg/m2;P=0.01). Other than for dyspnea, these findings were independent of the forced expiratory volume in one second. Seventeen percent of smokers without COPD on spirometry had emphysema, which was independently associated with reduced walk distance. Conclusions Emphysema subtypes on CT are common in smokers with and without COPD. Centrilobular and panlobular emphysema but not paraseptal emphysema have considerable symptomatic and physiological consequences. PMID:24384106

  4. Quantitative Computerized Two-Point Correlation Analysis of Lung CT Scans Correlates With Pulmonary Function in Pulmonary Sarcoidosis

    PubMed Central

    Erdal, Barbaros Selnur; Yildiz, Vedat; King, Mark A.; Patterson, Andrew T.; Knopp, Michael V.; Clymer, Bradley D.

    2012-01-01

    Background: Chest CT scans are commonly used to clinically assess disease severity in patients presenting with pulmonary sarcoidosis. Despite their ability to reliably detect subtle changes in lung disease, the utility of chest CT scans for guiding therapy is limited by the fact that image interpretation by radiologists is qualitative and highly variable. We sought to create a computerized CT image analysis tool that would provide quantitative and clinically relevant information. Methods: We established that a two-point correlation analysis approach reduced the background signal attendant to normal lung structures, such as blood vessels, airways, and lymphatics while highlighting diseased tissue. This approach was applied to multiple lung fields to generate an overall lung texture score (LTS) representing the quantity of diseased lung parenchyma. Using deidentified lung CT scan and pulmonary function test (PFT) data from The Ohio State University Medical Center’s Information Warehouse, we analyzed 71 consecutive CT scans from patients with sarcoidosis for whom simultaneous matching PFTs were available to determine whether the LTS correlated with standard PFT results. Results: We found a high correlation between LTS and FVC, total lung capacity, and diffusing capacity of the lung for carbon monoxide (P < .0001 for all comparisons). Moreover, LTS was equivalent to PFTs for the detection of active lung disease. The image analysis protocol was conducted quickly (< 1 min per study) on a standard laptop computer connected to a publicly available National Institutes of Health ImageJ toolkit. Conclusions: The two-point image analysis tool is highly practical and appears to reliably assess lung disease severity. We predict that this tool will be useful for clinical and research applications. PMID:22628487

  5. WE-FG-202-08: Assessment of Treatment Response Via Longitudinal Diffusion MRI On A MRI-Guided System: Initial Experience of Quantitative Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, X; Yang, Y; Yang, L

    Purpose: To report our initial experience of systematic monitoring treatment response using longitudinal diffusion MR images on a Co-60 MRI-guided radiotherapy system. Methods: Four patients, including 2 head-and-necks, 1 sarcoma and 1 GBM treated on a 0.35 Tesla MRI-guided treatment system, were analyzed. For each patient, 3D TrueFISP MRIs were acquired during CT simulation and before each treatment for treatment planning and patient setup purposes respectively. Additionally, 2D diffusion-weighted MR images (DWI) were acquired weekly throughout the treatment course. The gross target volume (GTV) and brainstem (as a reference structure) were delineated on weekly 3D TrueFISP MRIs to monitor anatomymore » changes, the contours were then transferred onto the corresponding DWI images after fusing with the weekly TrueFISP images. The patient-specific temporal and spatial variations during the entire treatment course, such as anatomic changes, target apparent diffusion coefficient (ADC) distribution were evaluated in a longitudinal pattern. Results: Routine MRI revealed progressive soft-tissue GTV volume changes (up to 53%) for the H&N cases during the treatment course of 5–7 weeks. Within the GTV, the mean ADC values varied from −44% (ADC decrease) to +26% (ADC increase) in a week. The gradual increase of ADC value was inversely associated with target volume variation for one H&N case. The maximal changes of mean ADC values within the brainstem were 5.3% for the H&N cases. For the large size sarcoma and GBM tumors, spatial heterogeneity and temporal variations were observed through longitudinal ADC analysis. Conclusion: In addition to the superior soft-tissue visualization, the 0.35T MR system on ViewRay showed the potential to quantitatively measure the ADC values for both tumor and normal tissues. For normal tissue that is minimally affected by radiation, its ADC values are reproducible. Tumor ADC values show temporal and spatial fluctuation that can be exploited for personalized adaptive therapy.« less

  6. Metastatic B-cell lymphoma masquerading as infectious retinitis and vasculitis.

    PubMed

    Say, Emil Anthony T; Knupp, Charles L; Gertsch, Kevin R; Chavala, Sai H

    2012-06-01

    Intraocular lymphoma is a rare ocular malignancy that may occur in the retina or the uvea. Retina or vitreoretinal lymphoma accounts for the majority of cases and is often secondary to diffuse large B-cell lymphoma. In the present study, a 66-year-old Caucasian male with a history of Waldenstrom's macroglobulinemia with diffuse large B-cell lymphoma, presented with blurred vision in the left eye one month following cycle 4 of an R-CHOP regimen. At the time of onset, the patient was being treated for bacterial pneumonia. Visual acuity was 20/25 in his right eye (OD) and 20/30 in the left (OS). Ophthalmologic examination showed intraretinal white infiltrates associated with hemorrhage in the superotemporal midperiphery of the retina and vitritis OS. Initial diagnostic considerations included infectious (cytomegalovirus retinitis, syphilis, toxoplasmosis, tuberculosis), inflammatory (retinal vasculitis associated with autoimmune disease or hypercoagulable states) or malignant (intraocular lymphoma) diseases. The patient did not respond to intravitreal injection of foscarnet and oral valgancyclovir. Systemic work-up and aqueous fluid biopsy were inconclusive. Diagnostic vitrectomy yielded inconclusive results and the patient continued to have progressive loss of vision. A repeat diagnostic vitrectomy with retinal and subretinal biopsy confirmed large B cells consistent with metastatic B-cell lymphoma. A concomitant PET/CT scan was performed that revealed bilateral new pulmonary nodules resulting in additional chemotherapy. Our case shows the diagnostic dilemmas in patients with systemic lymphoma and the possible role of concurrent systemic restaging in patients with ocular complaints, even when in systemic remission.

  7. Lattice Boltzmann simulation of dissolution-induced changes in permeability and porosity in 3D CO2 reactive transport

    NASA Astrophysics Data System (ADS)

    Tian, Zhiwei; Wang, Junye

    2018-02-01

    Dissolution and precipitation of rock matrix are one of the most important processes of geological CO2 sequestration in reservoirs. They change connections of pore channels and properties of matrix, such as bulk density, microporosity and hydraulic conductivity. This study builds on a recently developed multi-layer model to account for dynamic changes of microporous matrix that can accurately predict variations in hydraulic properties and reaction rates due to dynamic changes in matrix porosity and pore connectivity. We apply the model to simulate the dissolution and precipitation processes of rock matrix in heterogeneous porous media to quantify (1) the effect of the reaction rate on dissolution and matrix porosity, (2) the effect of microporous matrix diffusion on the overall effective diffusion and (3) the effect of heterogeneity on hydraulic conductivity. The results show the CO2 storage influenced by factors including the matrix porosity change, reaction front movement, velocity and initial properties. We also simulated dissolution-induced permeability enhancement as well as effects of initial porosity heterogeneity. The matrix with very low permeability, which can be unresolved on X-ray CT, do contribute to flow patterns and dispersion. The concentration of reactant H+ increases along the main fracture paths where the flow velocity increases. The product Ca++ shows the inversed distribution pattern against the H+ concentration. This demonstrates the capability of this model to investigate the complex CO2 reactive transport in real 3D heterogeneous porous media.

  8. Parametric PET/MR Fusion Imaging to Differentiate Aggressive from Indolent Primary Prostate Cancer with Application for Image-Guided Prostate Cancer Biopsies

    DTIC Science & Technology

    2013-10-01

    AD_________________ Award Number: W81XWH-12-1-0597 TITLE: Parametric PET /MR Fusion Imaging to...Parametric PET /MR Fusion Imaging to Differentiate Aggressive from Indolent Primary Prostate Cancer with Application for Image-Guided Prostate Cancer Biopsies...The study investigates whether fusion PET /MRI imaging with 18F-choline PET /CT and diffusion-weighted MRI can be successfully applied to target prostate

  9. The role of laparoscopy in the diagnosis and treatment of peritoneal carcinomatosis: a case report.

    PubMed Central

    Takizawa, B. T.; Shin, E. K.; Masters, L.; Lancelle, F.; Anaf, V.; Shahabi, S.

    2001-01-01

    A patient presented with deep venous thrombosis and an elevated CA-125 level, but normal pelvic ultrasound and abdominal and pelvic CT scans. Laparoscopy revealed diffuse carcinomatosis and a diagnosis of stage IIIc, poorly differentiated epithelial ovarian carcinoma was made. Laparoscopy may provide an alternative means of diagnosis when conventional imaging fails, and may facilitate the placement of catheters for subsequent intraperitoneal therapy. PMID:11393262

  10. The role of PET/CT in evaluation of Facet and Disc abnormalities in patients with low back pain using (18)F-Fluoride.

    PubMed

    Gamie, Sherief; El-Maghraby, Tarek

    2008-01-01

    Bone scintigraphy including Single Photon Emission Computed Tomography (SPECT) is known for its role in the diagnosis of low back pain disorders. Positron Emission Tomography (PET) with (18)F (Flouride-18) as a tracer can be used to carry out bone scans with improved image quality. With the addition of CT, simultaneous PET/CT fused images provide more accurate anatomical details. The objectives of this work are to assess the use of (18)F-PET/CT in patients with back pain and suspected facetogenic pain, and to find the frequency of facet arthropathy versus disc disease abnormalities. 67 patients who presented with back pain underwent routine X-ray, CT and/or MRI, which failed to identify a clear cause, were referred to (18)F-PET/CT. Among the main group, a subset of 25 patients had previous spine surgery consisting of laminectomy or discectomy (17 patients) and lumbar fusion (8 patients). The PET/CT scan was acquired on a GE VCT 64-Slice combined scanner. Imaging started 45-60 minutes after administration of 12-15 mCi (444-555 MBq) of (18)F-Fluoride. The PET scan was acquired from the skull base through the inguinal region in 3D mode at 2 minutes/bed. A lowresolution, non-contrast CT scan was also acquired for anatomic localization and attenuation correction. The (18)F-PET/CT showed abnormal uptake in the spine in 56 patients, with an overall detection ability of 84%. Facet joints as a cause of back pain was much more frequent (25 with abnormal scans). One-third (36%) of the patients showed multiple positive uptake in both facet joints and disc areas (20/56). The patients were further divided into two groups. Group A consisted of 42 patients (63%) with back pain and no previous operative procedures, and the (18)F-PET/CT showed a high sensitivity (88%) in identifying the source of pain in 37/42 patients. Group B included 25 patients (37%) with prior lumbar fusion or laminectomy, in which the PET/CT showed positive uptake in 76% (19/25 patients). (18)F-PET/CT showed positive uptake in all patients (100%) with a history of pain after lumbar fusion, while in the laminectomy subgroup only 11 cases (65%) showed positive focal uptake. (18)F-PET/CT has a potential use in evaluating adult patients with back pain. It has a promising role in identifying causes of persistent back pain following vertebral surgical interventions.

  11. Topology-guided deformable registration with local importance preservation for biomedical images

    NASA Astrophysics Data System (ADS)

    Zheng, Chaojie; Wang, Xiuying; Zeng, Shan; Zhou, Jianlong; Yin, Yong; Feng, Dagan; Fulham, Michael

    2018-01-01

    The demons registration (DR) model is well recognized for its deformation capability. However, it might lead to misregistration due to erroneous diffusion direction when there are no overlaps between corresponding regions. We propose a novel registration energy function, introducing topology energy, and incorporating a local energy function into the DR in a progressive registration scheme, to address these shortcomings. The topology energy that is derived from the topological information of the images serves as a direction inference to guide diffusion transformation to retain the merits of DR. The local energy constrains the deformation disparity of neighbouring pixels to maintain important local texture and density features. The energy function is minimized in a progressive scheme steered by a topology tree graph and we refer to it as topology-guided deformable registration (TDR). We validated our TDR on 20 pairs of synthetic images with Gaussian noise, 20 phantom PET images with artificial deformations and 12 pairs of clinical PET-CT studies. We compared it to three methods: (1) free-form deformation registration method, (2) energy-based DR and (3) multi-resolution DR. The experimental results show that our TDR outperformed the other three methods in regard to structural correspondence and preservation of the local important information including texture and density, while retaining global correspondence.

  12. [Plasma exchange and continuous hemodiafiltration as an initial treatment for diffuse large B-cell lymphoma-associated hemophagocytic syndrome].

    PubMed

    Yanagiya, Norimitsu; Takahashi, Naoto; Nakae, Hajime; Kume, Masaaki; Chubachi, Akihiko; Miura, Ikuo

    2002-01-01

    A 68-year-old man was admitted to our hospital because of fever, jaundice and hepatosplenomegaly. A diagnosis of diffuse large cell, B-cell type malignant lymphoma, associated with hemophagocytic syndrome (LAHS), was made. CT scan revealed lymphadenopathy in the abdominal cavity and multiple tumors in the spleen. Performance status and hepatic coma grade were 4 and II, respectively. Laboratory findings showed bicytopenia (Hb 9.9 g/dl, platelet 35 x 10(3)/microliter), severe liver dysfunction (ALP 1,115 U/l, gamma-GTP 437 U/l, T.Bil 15.4 mg/dl, D.Bil 12.8 mg/dl) and elevated levels of beta 2 microglobulin (12.9 mg/dl), ferritin (2,300 ng/ml) and sIL-2 receptor (36,900 U/ml). Plasma exchange (PE) and continuous hemodiafiltration (CHDF) enabled the patient to undergo diagnostic procedures, irradiation (total 34 Gy) and chemotherapy. Biopsy specimens revealed infiltration of lymphoma cells into the liver and bone marrow. We measured the blood concentrations of TNF-alpha, IL-6, and IL-8 before and after PE and CHDF by the ELISA method, and found normalization of hypercytokinemia after the procedure. It was suggested that initial treatment with PE and CHDF was effective for control of HPS, enabling us to perform chemotherapy for the lymphoma.

  13. Volume illustration of muscle from diffusion tensor images.

    PubMed

    Chen, Wei; Yan, Zhicheng; Zhang, Song; Crow, John Allen; Ebert, David S; McLaughlin, Ronald M; Mullins, Katie B; Cooper, Robert; Ding, Zi'ang; Liao, Jun

    2009-01-01

    Medical illustration has demonstrated its effectiveness to depict salient anatomical features while hiding the irrelevant details. Current solutions are ineffective for visualizing fibrous structures such as muscle, because typical datasets (CT or MRI) do not contain directional details. In this paper, we introduce a new muscle illustration approach that leverages diffusion tensor imaging (DTI) data and example-based texture synthesis techniques. Beginning with a volumetric diffusion tensor image, we reformulate it into a scalar field and an auxiliary guidance vector field to represent the structure and orientation of a muscle bundle. A muscle mask derived from the input diffusion tensor image is used to classify the muscle structure. The guidance vector field is further refined to remove noise and clarify structure. To simulate the internal appearance of the muscle, we propose a new two-dimensional example based solid texture synthesis algorithm that builds a solid texture constrained by the guidance vector field. Illustrating the constructed scalar field and solid texture efficiently highlights the global appearance of the muscle as well as the local shape and structure of the muscle fibers in an illustrative fashion. We have applied the proposed approach to five example datasets (four pig hearts and a pig leg), demonstrating plausible illustration and expressiveness.

  14. Enhancing 18F-FDG-PET/CT analysis in lung cancer patients. Is CT-CT image fusion helpful in predicting pleural involvement? A pilot study.

    PubMed

    Kapfhammer, A; Winkens, T; Lesser, T; Reissig, A; Steinert, M; Freesmeyer, M

    2015-01-01

    To retrospectively evaluate the feasibility and value of CT-CT image fusion to assess the shift of peripheral lung cancers with/-out chest wall infiltration, comparing computed tomography acquisitions in shallow-breathing (SB-CT) and deep-inspiration breath-hold (DIBH-CT) in patients undergoing FDG-PET/CT for lung cancer staging. Image fusion of SB-CT and DIBH-CT was performed with a multimodal workstation used for nuclear medicine fusion imaging. The distance of intrathoracic landmarks and the positional shift of tumours were measured using semi-transparent overlay of both CT series. Statistical analyses were adjusted for confounders of tumour infiltration. Cutoff levels were calculated for prediction of no-/infiltration. Lateral pleural recessus and diaphragm showed the largest respiratory excursions. Infiltrating lung cancers showed more limited respiratory shifts than non-infiltrating tumours. A large respiratory tumour-motility accurately predicted non-infiltration. However, the tumour shifts were limited and variable, limiting the accuracy of prediction. This pilot fusion study proved feasible and allowed a simple analysis of the respiratory shifts of peripheral lung tumours using CT-CT image fusion in a PET/CT setting. The calculated cutoffs were useful in predicting the exclusion of chest wall infiltration but did not accurately predict tumour infiltration. This method can provide additional qualitative information in patients with lung cancers with contact to the chest wall but unclear CT evidence of infiltration undergoing PET/CT without the need of additional investigations. Considering the small sample size investigated, further studies are necessary to verify the obtained results.

  15. Imaging Findings of Ulceroglandular Tularemia.

    PubMed

    Anand, Neil; Deochand, Osmani; Murphy, Robyn

    2017-01-01

    Francisella tularensis, the causative organism in Tularemia, is a relatively rare disease. There are a few radiological clues to elucidate its presence when suspicion arises. There should be strong consideration for Tularemia in the differential of any patient with its classic symptoms, diffuse cervical lymphadenopathy with evidence of necrosis, and enlarged adenoids. Ultrasound may demonstrate suppurative lymphadenopathy suggestive of infection, as in the case presented. CT often will demonstrate the extent of lymphadenopathy. On chest radiography, tularemia pneumonia is often the presenting finding, which may demonstrate bilateral or lobar infiltrates. Additionally, hilar lymphadenopathy and pleural effusions are often associated findings. Cavitary lesions may be present, which are better delineated on CT scan. We present a case of a 7-year-old male who presented with a painful right-sided palpable neck mass for 9 days, who was diagnosed with Tularemia after numerous admissions.

  16. Imaging Findings of Ulceroglandular Tularemia

    PubMed Central

    Anand, Neil; Deochand, Osmani; Murphy, Robyn

    2017-01-01

    Francisella tularensis, the causative organism in Tularemia, is a relatively rare disease. There are a few radiological clues to elucidate its presence when suspicion arises. There should be strong consideration for Tularemia in the differential of any patient with its classic symptoms, diffuse cervical lymphadenopathy with evidence of necrosis, and enlarged adenoids. Ultrasound may demonstrate suppurative lymphadenopathy suggestive of infection, as in the case presented. CT often will demonstrate the extent of lymphadenopathy. On chest radiography, tularemia pneumonia is often the presenting finding, which may demonstrate bilateral or lobar infiltrates. Additionally, hilar lymphadenopathy and pleural effusions are often associated findings. Cavitary lesions may be present, which are better delineated on CT scan. We present a case of a 7-year-old male who presented with a painful right-sided palpable neck mass for 9 days, who was diagnosed with Tularemia after numerous admissions. PMID:28580063

  17. Petroleum degradation by Pseudomonas sp. ZS1 is impeded in the presence of antagonist Alcaligenes sp. CT10.

    PubMed

    Liang, Jibei; Cheng, Tao; Huang, Yi; Liu, Jianhua

    2018-05-28

    Enhanced bioremediation is a favorable approach for petroleum pollutant cleanup, which depends on the growth of oil-eating microorganisms. In this study, we show that, by using the modified T-RFLP (mT-RFLP) methodology, one of the four major microbial populations derived from oil sludge has failed to propagate in MS medium supplemented with 2% yeast extract (YE). rDNA sequence-based analysis indicated that the four populations were Donghicola sp. CT5, Bacillus sp. CT6, Alcaligenes sp. CT10, and Pseudomonas sp. ZS1. Four purified strains grow well individually in MS medium supplemented with 2% YE, suggesting that ZS1 growth is antagonized by other strains. Co-growth analysis using mT-RFLP methodology and plate inhibitory assay indicated that ZS1 exhibited antagonistic effect against CT5 and CT6. On the other hand, co-growth analysis and plate inhibition assay showed that CT10 antagonized against ZS1. To investigate the potential compounds responsible for the antagonism, supernatant of CT10 culture was subjected to GC-MS analysis. Analysis indicated that CT10 produced a number of antimicrobial compounds including cyclodipeptide c-(L-Pro-L-Phe), which was known to inhibit the growth of Pseudomonas sp. Growth test using the purified c-(L-Pro-L-Phe) from CT10 confirmed its inhibitory activity. We further showed that, using both gravimetric and GC analysis, CT10 antagonism against the oil-eating ZS1 led to the diminishing of crude oil degradation. Together, our results indicate that bioremediation can be affected by environmental antagonists.

  18. Evaluation of visual and computer-based CT analysis for the identification of functional patterns of obstruction and restriction in hypersensitivity pneumonitis.

    PubMed

    Jacob, Joseph; Bartholmai, Brian J; Brun, Anne Laure; Egashira, Ryoko; Rajagopalan, Srinivasan; Karwoski, Ronald; Kouranos, Vasileios; Kokosi, Maria; Hansell, David M; Wells, Athol U

    2017-11-01

    To determine whether computer-based quantification (CALIPER software) is superior to visual computed tomography (CT) scoring in the identification of CT patterns indicative of restrictive and obstructive functional indices in hypersensitivity pneumonitis (HP). A total of 135 consecutive HP patients had CT parenchymal patterns evaluated quantitatively by both visual scoring and CALIPER. Results were evaluated against: forced vital capacity (FVC), total lung capacity (TLC), diffusing capacity for carbon monoxide (DL CO ) and a composite physiological index (CPI) to identify which CT scoring method better correlated with functional indices. CALIPER-derived scores of total interstitial lung disease extent correlated more strongly than visual scores: FVC (CALIPER R = 0.73, visual R = 0.51); DL CO (CALIPER R = 0.61, visual R = 0.48); and CPI (CALIPER R = 0·70, visual R = 0·55). The CT variable that correlated most strongly with restrictive functional indices was CALIPER pulmonary vessel volume (PVV): FVC R = 0.75, DL CO R = 0.68 and CPI R = 0.76. Ground-glass opacity quantified by CALIPER alone demonstrated strong associations with restrictive functional indices: CALIPER FVC R = 0.65; DL CO R = 0.59; CPI R = 0.64; and visual = not significant. Decreased attenuation lung quantified by CALIPER was a better morphological measure of obstructive lung disease than equivalent visual scores as judged by relationships with TLC (CALIPER R = 0.63 and visual R = 0.12). All results were maintained on multivariate analysis. CALIPER improved on visual scoring in HP as judged by restrictive and obstructive functional correlations. Decreased attenuation regions of the lung quantified by CALIPER demonstrated better linkages to obstructive lung physiology than visually quantified CT scores. A novel CALIPER variable, the PVV, demonstrated the strongest linkages with restrictive functional indices and could represent a new automated index of disease severity in HP. © 2017 Asian Pacific Society of Respirology.

  19. Size variation and collapse of emphysema holes at inspiration and expiration CT scan: evaluation with modified length scale method and image co-registration

    PubMed Central

    Oh, Sang Young; Lee, Minho; Seo, Joon Beom; Kim, Namkug; Lee, Sang Min; Lee, Jae Seung; Oh, Yeon Mok

    2017-01-01

    A novel approach of size-based emphysema clustering has been developed, and the size variation and collapse of holes in emphysema clusters are evaluated at inspiratory and expiratory computed tomography (CT). Thirty patients were visually evaluated for the size-based emphysema clustering technique and a total of 72 patients were evaluated for analyzing collapse of the emphysema hole in this study. A new approach for the size differentiation of emphysema holes was developed using the length scale, Gaussian low-pass filtering, and iteration approach. Then, the volumetric CT results of the emphysema patients were analyzed using the new method, and deformable registration was carried out between inspiratory and expiratory CT. Blind visual evaluations of EI by two readers had significant correlations with the classification using the size-based emphysema clustering method (r-values of reader 1: 0.186, 0.890, 0.915, and 0.941; reader 2: 0.540, 0.667, 0.919, and 0.942). The results of collapse of emphysema holes using deformable registration were compared with the pulmonary function test (PFT) parameters using the Pearson’s correlation test. The mean extents of low-attenuation area (LAA), E1 (<1.5 mm), E2 (<7 mm), E3 (<15 mm), and E4 (≥15 mm) were 25.9%, 3.0%, 11.4%, 7.6%, and 3.9%, respectively, at the inspiratory CT, and 15.3%, 1.4%, 6.9%, 4.3%, and 2.6%, respectively at the expiratory CT. The extents of LAA, E2, E3, and E4 were found to be significantly correlated with the PFT parameters (r=−0.53, −0.43, −0.48, and −0.25), with forced expiratory volume in 1 second (FEV1; −0.81, −0.62, −0.75, and −0.40), and with diffusing capacity of the lungs for carbon monoxide (cDLco), respectively. The fraction of emphysema that shifted to the smaller subgroup showed a significant correlation with FEV1, cDLco, forced expiratory flow at 25%–75% of forced vital capacity, and residual volume (RV)/total lung capacity (r=0.56, 0.73, 0.40, and −0.58). A detailed assessment of the size variation and collapse of emphysema holes may be useful for understanding the dynamic collapse of emphysema and its functional relation. PMID:28761337

  20. Massive Ischemic Stroke Due to Pulmonary Barotrauma and Cerebral Artery Air Embolism During Commercial Air Travel

    PubMed Central

    Zarabi, Sara Farshchi; Parotto, Matteo; Katznelson, Rita; Downar, James

    2017-01-01

    Patient: Male, 65 Final Diagnosis: Air emboli Symptoms: Short of breath Medication: — Clinical Procedure: — Specialty: Anesthesiology Objective: Unusual setting of medical care Background: Air embolism into the systemic arterial circulation secondary to pulmonary barotrauma has rarely been reported. Herein, we report the clinical course of an extremely rare presentation of cerebral air embolism likely due to ruptured pulmonary bullae during commercial air travel. Case Report: A 65-year-old man suddenly became unconscious during an airplane descent. Upon landing, he was immediately transferred to the nearest emergency department where he was intubated for airway protection. His head CT angiogram showed multiple air pockets in the right parietal lobe suspicious for multiple air emboli. His chest CT scan showed multiple large bullae in the left upper and lower lobes as well as diffusely emphysematous lung tissue. After initial stabilization, he underwent emergent hyperbaric oxygen treatment (HBOT) in the multiplace chamber at 2.8 atmospheres. The patient tolerated HBOT well with no complications. However, his neurologic status deteriorated in the following 24 hours due to progression of his cerebral edema and mass effects. The patient’s clinical status was discussed with his family and the decision was made to withdraw life-sustaining measures. He died shortly after withdrawal of life support. Post-mortem examination confirmed the presence of very large bullae in the lungs bilaterally. Conclusions: Spontaneous cerebral air embolism is a possible complication of ruptured pulmonary bullae during air travel. HBOT is well-tolerated and may be used with caution even in the presence of emphysematous bullae. PMID:28607332

  1. Catechin-loaded Eudragit microparticles for the management of diabetes: formulation, characterization and in vivo evaluation of antidiabetic efficacy.

    PubMed

    Meena, Kedar Prasad; Vijayakumar, Mahalingam Rajamanickam; Dwibedy, Priti S

    2017-06-01

    Catechin (CT) is natural molecule proved for antidiabetic activity. Clinical application of CT is highly restricted because of its low bioavailability and ineffectiveness in in vivo conditions. Therefore, the main objective of the present investigation was to formulate CT-loaded Eudragit RS 100 microparticles and evaluated for its potential against diabetes. CT microparticles showing highest entrapment efficiency of 92.3 ± 6.5% and higher percentage yield of 63.46 ± 4.3% was selected as optimised formulation. CT microparticles treated rats showed significantly lower blood glucose, cholesterol, LDL, free fatty acid and triglyceride concentrations in comparison to pristine CT-treated rats. The glucose and lipid profiles of microparticle formulation were akin to normal rats. Moreover, CT microparticles did not produce obesity even after 60 days which is a comment side effect of antidiabetic drugs. These results indicate that the CT microparticles can be applied as potential and safe carrier for the treatment of diabetes.

  2. Long Distance Endovascular Growth of Jugulotympanic Paraganglioma Evident in 68Ga-DOTATATE PET but Concealed on CT.

    PubMed

    Avramovic, Nemanja; Weckesser, Matthias; Velasco, Aglaé; Stenner, Markus; Noto, Benjamin

    2017-02-01

    A 60-year-old woman was referred to contrast-enhanced CT for evaluation of jugular vein thrombosis incidentally detected by ultrasound. Contrast-enhanced CT showed an enhanced tumor of the right skull base highly suspicious of jugulotympanic paraganglioma. However, the jugular veins showed a nearly symmetric contrast enhancement without clear evidence of thrombosis. Consecutive Ga-DOTATATE PET/CT depicted high tumor uptake, which comprised the entire internal jugular vein. Endovascular growth of paraganglioma might be missed on contrast-enhanced CT because of high vascularization of the lesion. Ga-DOTATATE PET is suited for accurate determination of tumor extent.

  3. Mutual influences between partners' hormones shape conflict dialog and relationship duration at the initiation of romantic love.

    PubMed

    Schneiderman, Inna; Kanat-Maymon, Yaniv; Zagoory-Sharon, Orna; Feldman, Ruth

    2014-01-01

    Early-stage romantic love involves reorganization of neurohormonal systems and behavioral patterns marked by mutual influences between the partners' physiology and behavior. Guided by the biobehavioral synchrony conceptual frame, we tested bidirectional influences between the partners' hormones and conflict behavior at the initiation of romantic love. Participants included 120 new lovers (60 couples) and 40 singles. Plasma levels of five affiliation and stress-related hormones were assessed: oxytocin (OT), prolactin (PRL), testosterone (T), cortisol (CT), and dehydroepiandrosterone sulfate (DHEAS). Couples were observed in conflict interaction coded for empathy and hostility. CT and DHEAS showed direct actor effects: higher CT and DHEAS predicted greater hostility. OT showed direct partner effects: individuals whose partners had higher OT showed greater empathy. T and CT showed combined actor-partner effects. High T predicted greater hostility only when partner also had high T, but lower hostility when partner had low T. Similarly, CT predicted low empathy only in the context of high partner's CT. Mediational analysis indicated that combined high CT in both partners was associated with relationship breakup as mediated by decrease in empathy. Findings demonstrate the mutual influences between hormones and behavior within an attachment bond and underscore the dynamic, co-regulated, and systemic nature of pair-bond formation in humans.

  4. SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, M; Foster, R; Parks, H

    Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-simmore » and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between the plans on CT-sim with assigned CT-number and the deformable SEMAR CT datasets.« less

  5. Image quality of conventional images of dual-layer SPECTRAL CT: A phantom study.

    PubMed

    van Ommen, Fasco; Bennink, Edwin; Vlassenbroek, Alain; Dankbaar, Jan Willem; Schilham, Arnold M R; Viergever, Max A; de Jong, Hugo W A M

    2018-05-10

    Spectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips Healthcare) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips Healthcare), by means of phantom experiments. For both CT scanners, conventional CT images were acquired using four adult scanning protocols: (a) body helical, (b) body axial, (c) head helical, and (d) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. The resolution levels at 50%, 10%, and 5% MTF of the iCT and IQon showed small, but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with differences up to 0.51. Spatial resolution did not change with phantom size, but noise levels increased significantly. For head scans, IQon had a noise level that was significantly lower than the iCT, on the other hand IQon showed noise levels significantly higher than the iCT for body scans. Still, these differences were well within the specified range of performance of iCT scanners. At equivalent dose levels, this study showed similar quality of conventional images acquired on iCT and IQon for medium-sized phantoms and slightly degraded image quality for (very) large phantoms at lower tube voltages on the IQon. Accordingly, it may be concluded that the introduction of a dual-layer detector neither compromises image quality of conventional images nor increases radiation dose for normal-sized patients, and slightly degrades dose efficiency for large patients at 120 kVp and lower tube voltages. © 2018 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  6. 68Ga-PSMA PET-CT Imaging of Metastatic Adenoid Cystic Carcinoma.

    PubMed

    de Keizer, Bart; Krijger, Gerard C; Ververs, F Tessa; van Es, Robert J J; de Bree, Remco; Willems, Stefan

    2017-12-01

    A patient with a history of adenoid cystic carcinoma of the nasal cavity presented himself with bone pain and an elevated PSA level. On suspicion of metastatic prostate cancer a 68 Ga-PSMA PET-CT was performed. The PET-CT showed numerous lung and non-sclerotic bone metastasis. Biopsy of a bone metastasis was performed and pathology showed adenoid cystic carcinoma instead of prostate cancer. Immunohistochemical PSMA staining of the primary tumour showed intense PSMA expression in adenoid cystic carcinoma tumour cells. Because of the high PSMA expression of adenoid cystic carcinoma, 68 Ga-PSMA PET-CT might be a promising imaging modality for this malignancy.

  7. [Pulmonary Langerhans' cell histiocytosis (PLCH) revealed by pneumothorax: about a case].

    PubMed

    Sajiai, Hafsa; Rachidi, Mariam; Serhane, Hind; Aitbatahar, Salma; Amro, Lamyae

    2016-01-01

    Langerhans cell histiocytosis is a rare disease of unknown etiology characterized by the infiltration of Langerhans cells in one or more organs. It has a polymorphic clinical presentation. We report the case of Mr R.Y, age 22, with 8 pack year history of smoking, admitted to hospital with complete spontaneous right-sided pneumothorax. Chest drainage was performed with good evolution. Control chest CT scan showed multiple diffuse cyst formations, predominant in the upper lobes. Lab and imaging tests were performed in order to detect systemic histiocytosis with negative results. Patient's evolution was marked by pneumothorax recurrence; pleurodesis and lung biopsy were performed which confirmed the diagnosis. The diagnosis of Langerhans cell histiocytosis should be evoked in front of pneumothorax associated with lung cystic. The diagnosis is easy in front of a suggestive clinical and radiological picture. Nevertheless, therapeutic options are limited and pneumothorax recurrence is common.

  8. Radiosensitive orbital metastasis as presentation of occult colonic adenocarcinoma.

    PubMed

    Ludmir, Ethan B; McCall, Shannon J; Czito, Brian G; Palta, Manisha

    2014-09-19

    An 82-year-old man presented with progressive right frontal headaches. The patient's history was significant for benign polyps on surveillance colonoscopy 2 years prior, without high-grade dysplasia or carcinoma. MRI revealed an enhancing lesion arising within the superomedial aspect of the right orbit. Lesion biopsy demonstrated histological appearance and immunophenotype suggestive of colonic adenocarcinoma. Staging positron emission tomography/CT showed visceral metastases and diffuse activity in the posterior rectosigmoid, consistent with metastatic colon cancer. Treatment of the orbital lesion with external beam radiotherapy to 30 Gy resulted in significant palliation of the patient's headaches. The patient expired 2 months following treatment completion due to disease progression. Orbital metastasis as the initial presentation of an occult colorectal primary lesion is exceedingly rare, and occurred in this patient despite surveillance colonoscopy. Radiotherapy remains an efficacious modality for treatment of orbital metastases. 2014 BMJ Publishing Group Ltd.

  9. Magnetic resonance characteristics and susceptibility weighted imaging of the brain in gadolinium encephalopathy.

    PubMed

    Samardzic, Dejan; Thamburaj, Krishnamoorthy

    2015-01-01

    To report the brain imaging features on magnetic resonance imaging (MRI) in inadvertent intrathecal gadolinium administration. A 67-year-old female with gadolinium encephalopathy from inadvertent high dose intrathecal gadolinium administration during an epidural steroid injection was studied with multisequence 3T MRI. T1-weighted imaging shows pseudo-T2 appearance with diffusion of gadolinium into the brain parenchyma, olivary bodies, and membranous labyrinth. Nulling of cerebrospinal fluid (CSF) signal is absent on fluid attenuation recovery (FLAIR). Susceptibility-weighted imaging (SWI) demonstrates features similar to subarachnoid hemorrhage. CT may demonstrate a pseudo-cerebral edema pattern given the high attenuation characteristics of gadolinium. Intrathecal gadolinium demonstrates characteristic imaging features on MRI of the brain and may mimic subarachnoid hemorrhage on susceptibility-weighted imaging. Identifying high dose gadolinium within the CSF spaces on MRI is essential to avoid diagnostic and therapeutic errors. Copyright © 2013 by the American Society of Neuroimaging.

  10. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    PubMed Central

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images, as compared to the reference magnetic resonance images. The difference in accuracy was statistically significant (P = 0.02). CONCLUSION: New generation CT scanner, using high resolution MPR images, represents a reliable diagnostic tool in assessment of loco-regional and whole body staging of advanced rectal cancer, especially in patients with MRI contraindications. PMID:27239115

  11. Chest ultrasonography in health surveillance of asbestos-related lung diseases.

    PubMed

    Smargiassi, Andrea; Pasciuto, Giuliana; Pedicelli, Ilaria; Lo Greco, Erminia; Calvello, Mariarosaria; Inchingolo, Riccardo; Schifino, Gioacchino; Capoluongo, Patrizio; Patriciello, Pasquale; Manno, Maurizio; Cirillo, Alfonso; Corbo, Giuseppe Maria; Soldati, Gino; Iavicoli, Ivo

    2017-06-01

    Exposure to asbestos fibers can lead to different lung diseases, such as pleural thickening and effusion, asbestosis, mesothelioma, and lung cancer. These diseases are expected to peak in the next few years. The aim of the study was to validate ultrasonography (US) as a diagnostic tool in the management of lung diseases in subjects with a history of occupational exposure to asbestos. Fifty-nine retired male workers previously exposed to asbestos were enrolled in the study. Chest US was performed in all the subjects. The US operator was blinded to earlier performed computed tomography (CT) scan reports and images. The sonographic pathological findings were pleural thickening (with or without calcifications), peripheral lung consolidation, and focal sonographic interstitial syndrome and diffuse pneumogenic sonographic interstitial syndrome (pulmonary asbestosis). Significant US findings were recorded, stored, and subsequently compared with CT scans. With some patients falling into more than one category, on CT scan, pleural thickening was reported in 33 cases (56%, 26 with calcifications), focal interstitial peripheral alterations in 23 (39%), asbestosis in 6 (10%), and peripheral lung consolidation in 13 cases (22%). Comparing each pathological condition to CT scan reports, US findings had high levels of sensitivity, specificity, positive, and negative predictive values. US did not prove effective for the detection of central lung nodules or diaphragmatic pleural thickenings. Chest US was considered to be the best technique to detect minimal pleural effusions (six subjects, 10%). Chest US might be considered an additional tool to follow up subjects occupationally exposed to asbestos who have already undergone CT scan examination and whose pathology is detectable by US as well.

  12. Correlation of 68Ga Ventilation-Perfusion PET/CT with Pulmonary Function Test Indices for Assessing Lung Function.

    PubMed

    Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S

    2015-11-01

    Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P < 0.05). FEV1/FVC and %NVQ had the highest correlation (r = 0.82). FEV1 was also best correlated with %NVQ (r = 0.64). DLCO was best correlated with the volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  13. Correlation of pulmonary function and usual interstitial pneumonia computed tomography patterns in idiopathic pulmonary fibrosis.

    PubMed

    Arcadu, Antonella; Byrne, Suzanne C; Pirina, Pietro; Hartman, Thomas E; Bartholmai, Brian J; Moua, Teng

    2017-08-01

    Little is known about presenting 'inconsistent' or 'possible' usual interstitial pneumonia (UIP) computed tomography (CT) patterns advancing to 'consistent' UIP as disease progresses in idiopathic pulmonary fibrosis (IPF). We hypothesized that if 'consistent' UIP represented more advanced disease, such a pattern on presentation should also correlate with more severe pulmonary function test (PFT) abnormalities. Consecutive IPF patients (2005-2013) diagnosed by international criteria with baseline PFT and CT were included. Presenting CTs were assessed by three expert radiologists for consensus UIP pattern ('consistent', 'possible', and 'inconsistent'). Approximation of individual and combined interstitial abnormalities was also performed with correlation of interstitial abnormalities and UIP CT pattern made with PFT findings and survival. Three-hundred and fifty patients (70% male) were included with a mean age of 68.3 years. Mean percent predicted forced vital capacity (FVC%) and diffusion capacity (DLCO%) was 64% and 45.5% respectively. Older age and male gender correlated more with 'consistent' UIP CT pattern. FVC% was not associated with any UIP pattern but did correlate with total volume of radiologist assessed interstitial abnormalities. DLCO% was lower in those with 'consistent' UIP pattern. A 'consistent' UIP CT pattern was also not independently predictive of survival after correction for age, gender, FVC%, and DLCO%. PFT findings appear to correlate with extent of radiologic disease but not specific morphologic patterns. Whether such UIP patterns represent different stages of disease severity or radiologic progression is not supported by coinciding pulmonary function decline. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Development of a prediction model for residual disease in newly diagnosed advanced ovarian cancer.

    PubMed

    Janco, Jo Marie Tran; Glaser, Gretchen; Kim, Bohyun; McGree, Michaela E; Weaver, Amy L; Cliby, William A; Dowdy, Sean C; Bakkum-Gamez, Jamie N

    2015-07-01

    To construct a tool, using computed tomography (CT) imaging and preoperative clinical variables, to estimate successful primary cytoreduction for advanced epithelial ovarian cancer (EOC). Women who underwent primary cytoreductive surgery for stage IIIC/IV EOC at Mayo Clinic between 1/2/2003 and 12/30/2011 and had preoperative CT images of the abdomen and pelvis within 90days prior to their surgery available for review were included. CT images were reviewed for large-volume ascites, diffuse peritoneal thickening (DPT), omental cake, lymphadenopathy (LP), and spleen or liver involvement. Preoperative factors included age, body mass index (BMI), Eastern Cooperative Oncology Group performance status (ECOG PS), American Society of Anesthesiologists (ASA) score, albumin, CA-125, and thrombocytosis. Two prediction models were developed to estimate the probability of (i) complete and (ii) suboptimal cytoreduction (residual disease (RD) >1cm) using multivariable logistic analysis with backward and stepwise variable selection methods. Internal validation was assessed using bootstrap resampling to derive an optimism-corrected estimate of the c-index. 279 patients met inclusion criteria: 143 had complete cytoreduction, 26 had suboptimal cytoreduction (RD>1cm), and 110 had measurable RD ≤1cm. On multivariable analysis, age, absence of ascites, omental cake, and DPT on CT imaging independently predicted complete cytoreduction (c-index=0.748). Conversely, predictors of suboptimal cytoreduction were ECOG PS, DPT, and LP on preoperative CT imaging (c-index=0.685). The generated models serve as preoperative evaluation tools that may improve counseling and selection for primary surgery, but need to be externally validated. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Synthesis, characterization, and catalytic activity of type 2 crystalline titanates prepared with supercritical drying

    NASA Astrophysics Data System (ADS)

    Al-Adwani, Hamad A. H.

    Supercritically dried silico-alumino-titanate (Si-Al-Ti) mixed oxides (T2CT) were successfully synthesized by a sol-gel method with hydrothermal synthesis temperatures less than 200°C and autogenic pressure. High-surface-area T2CT aerogels with meso- to macroporosity were obtained. All solid products, after calcination at 450°C, are semicrystalline. In addition, successful scale-up of T2CT synthesis in a one-gallon reactor yielding 500 g was achieved. Surface areas, pore volumes, and average pore diameters are greatly influenced by the drying method. Supercritical drying had no effect on the crystalline or molecular structure of the materials. The synthesized materials were characterized by means of nitrogen physisorption, X-ray diffraction (XRD), thermal analysis, and diffuse reflectance FTIR spectroscopy. The addition of different amounts of phosphorous and antimony affected neither the textural nor the structural aspects of T2CT. However, a decrease in surface area occurred. The catalytic activity of these materials was evaluated after being loaded with nickel and molybdenum by the incipient wetness method. Cyclohexene hydrogenation and thiophene hydrodesulfurization reactions are used in the catalytic activity study. The activities of some of the catalyst prepared in this study are in the same range as the commercial catalyst, Shell 324, but with lower metal loadings than the commercial catalysts. Thus, more efficient use of Mo and Ni was observed.

  16. Radiological Evaluation of Artificial Stone Silicosis Outbreak: Emphasizing Findings in Lung Transplant Recipients.

    PubMed

    Grubstein, Ahuva; Shtraichman, Osnat; Fireman, Elizabeth; Bachar, Gil N; Noach-Ophir, Noa; Kramer, Mordechai R

    The aim of this study was to describe the computed tomography (CT) findings and correlate pulmonary function tests (PFTs) of silicosis patients with emphasis on the findings in lung transplantation (LTX) recipients. We studied the chest CT scans from 82 marble workers exposed to artificial stone dust and who had a diagnosis of silicosis, of whom 13 patients underwent LTX. Silicosis-associated findings were graded and correlated to concomitant PFT. A statistically significant inverse relationship was found between chest CT scores and PFT including forced expired volume in the first second (r = -0.54, P < 0.0001), total lung capacity (r = -0.4, P < 0.0001), and diffusion capacity for carbon monoxide single breath % (r = -0.6, P < 0.0001) parameters. Progressive massive fibrosis indicating advanced and complicated silicosis was found in 85% of LTX patients, as compared with 40% in patients with maintained pulmonary function. Ground-glass opacities were seen in some LTX patients with or without signs of progressive massive fibrosis. Two of these patients had silicoproteinosis diagnosed within the resected lung, indicating an acute or accelerated form of silicosis. This silicosis current outbreak is important because of the worldwide use of this and similar high-silica-content, artificial stone products, which can cause progressive severe forms of silicosis. Along with standard clinical assessment and PFT, CT parameters are indicative measures of the disease severity.

  17. A Rare Case of Malignant Melanoma of the Mandible: 
CT and MRI Findings.

    PubMed

    Ogura, Ichiro; Sasaki, Yoshihiko; Kameta, Ayako; Sue, Mikiko; Oda, Takaaki

    Malignant melanoma of the mandibular gingiva is extremely rare. It is a malignant tumour of melanocytes or their precursor cells, and often misinterpreted as a benign pigmented process. A few reports have described computed tomography (CT) and magnetic resonance imaging (MRI) findings of malignant melanoma in the oral cavity. We report a rare case of malignant melanoma of the mandible and the related CT and MRI findings. Soft tissue algorithm contrast-enhanced CT showed an expansile mass and irregular destruction of alveolar bone in the right side of the mandibular molar area. MR images showed an enhancing mass and the tumour had a low to intermediate signal intensity and a high-signal intensity. Soft tissue algorithm contrast-enhanced CT and MR images showed lymphadenopathy involving the submandibular lymph nodes. Histopathological examination confirmed the diagnosis of malignant melanoma.

  18. Molecular packing and electronic processes in amorphous-like polymer bulk heterojunction solar cells with fullerene intercalation.

    PubMed

    Xiao, Ting; Xu, Haihua; Grancini, Giulia; Mai, Jiangquan; Petrozza, Annamaria; Jeng, U-Ser; Wang, Yan; Xin, Xin; Lu, Yong; Choon, Ng Siu; Xiao, Hu; Ong, Beng S; Lu, Xinhui; Zhao, Ni

    2014-06-09

    The interpenetrating morphology formed by the electron donor and acceptor materials is critical for the performance of polymer:fullerene bulk heterojunction (BHJ) photovoltaic (PV) cells. In this work we carried out a systematic investigation on a high PV efficiency (>6%) BHJ system consisting of a newly developed 5,6-difluorobenzo[c] thiadiazole-based copolymer, PFBT-T20TT, and a fullerene derivative. Grazing incidence X-ray scattering measurements reveal the lower-ordered nature of the BHJ system as well as an intermixing morphology with intercalation of fullerene molecules between the PFBT-T20TT lamella. Steady-state and transient photo-induced absorption spectroscopy reveal ultrafast charge transfer (CT) at the PFBT-T20TT/fullerene interface, indicating that the CT process is no longer limited by exciton diffusion. Furthermore, we extracted the hole mobility based on the space limited current (SCLC) model and found that more efficient hole transport is achieved in the PFBT-T20TT:fullerene BHJ as compared to pure PFBT-T20TT, showing a different trend as compared to the previously reported highly crystalline polymer:fullerene blend with a similar intercalation manner. Our study correlates the fullerene intercalated polymer lamella morphology with device performance and provides a coherent model to interpret the high photovoltaic performance of some of the recently developed weakly-ordered BHJ systems based on conjugated polymers with branched side-chain.

  19. Sequential weighted Wiener estimation for extraction of key tissue parameters in color imaging: a phantom study

    NASA Astrophysics Data System (ADS)

    Chen, Shuo; Lin, Xiaoqian; Zhu, Caigang; Liu, Quan

    2014-12-01

    Key tissue parameters, e.g., total hemoglobin concentration and tissue oxygenation, are important biomarkers in clinical diagnosis for various diseases. Although point measurement techniques based on diffuse reflectance spectroscopy can accurately recover these tissue parameters, they are not suitable for the examination of a large tissue region due to slow data acquisition. The previous imaging studies have shown that hemoglobin concentration and oxygenation can be estimated from color measurements with the assumption of known scattering properties, which is impractical in clinical applications. To overcome this limitation and speed-up image processing, we propose a method of sequential weighted Wiener estimation (WE) to quickly extract key tissue parameters, including total hemoglobin concentration (CtHb), hemoglobin oxygenation (StO2), scatterer density (α), and scattering power (β), from wide-band color measurements. This method takes advantage of the fact that each parameter is sensitive to the color measurements in a different way and attempts to maximize the contribution of those color measurements likely to generate correct results in WE. The method was evaluated on skin phantoms with varying CtHb, StO2, and scattering properties. The results demonstrate excellent agreement between the estimated tissue parameters and the corresponding reference values. Compared with traditional WE, the sequential weighted WE shows significant improvement in the estimation accuracy. This method could be used to monitor tissue parameters in an imaging setup in real time.

  20. Contribution of Jahn-Teller and charge transfer excitations to the photovoltaic effect of manganite/titanite heterojunctions

    NASA Astrophysics Data System (ADS)

    Ifland, Benedikt; Hoffmann, Joerg; Kressdorf, Birte; Roddatis, Vladimir; Seibt, Michael; Jooss, Christian

    2017-06-01

    The effect of correlation effects on photovoltaic energy conversion at manganite/titanite heterojunctions is investigated. As a model system we choose a heterostructure consisting of the small polaron absorber Pr0.66Ca0.34MnO3 (PCMO) epitaxially grown on single-crystalline Nb-doped SrTi0.998Nb0.002O3 (STNO) substrates. The high structural and chemical quality of the interfaces is proved by detailed characterization using high-resolution transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS) studies. Spectrally resolved and temperature-dependent photovoltaic measurements show pronounced contributions of both the Jahn-Teller (JT) excitations and the charge transfer (CT) transitions to the photovoltaic effect at different photon energies. A linear temperature dependence of the open-circuit voltage for an excitation in the PCMO manganite is only observed below the charge-ordering temperature, indicating that the diffusion length of the photocarrier exceeds the size of the space charge region. The photovoltaic response is compared to that of a heterojunction of lightly doped Pr0.05Ca0.95MnO3 (CMO)/STNO, where the JT transition is absent. Here, significant contributions of the CT transition to the photovoltaic effect set in below the Neel temperature. We conclude that polaronic correlations and ordering effects are essentials for photovoltaic energy conversion in manganites.

  1. Pre-treatment with Bifidobacterium breve UCC2003 modulates Citrobacter rodentium-induced colonic inflammation and organ specificity.

    PubMed

    Collins, James W; Akin, Ali R; Kosta, Artemis; Zhang, Ning; Tangney, Mark; Francis, Kevin P; Frankel, Gad

    2012-11-01

    Citrobacter rodentium, which colonizes the gut mucosa via formation of attaching and effacing (A/E) lesions, causes transmissible colonic hyperplasia. The aim of this study was to evaluate whether prophylactic treatment with Bifidobacterium breve UCC2003 can improve the outcome of C. rodentium infection. Six-week-old albino C57BL/6 mice were pre-treated for 3 days with B. breve, challenged with bioluminescent C. rodentium and administered B. breve or PBS-C for 8 days post-infection; control mice were either administered B. breve and mock-infected with PBS, or mock-treated with PBS-C and mock-infected with PBS. C. rodentium colonization was monitored by bacterial enumeration from faeces and by a combination of both 2D bioluminescence imaging (BLI) and composite 3D diffuse light imaging tomography with µCT imaging (DLIT-µCT). At day 8 post-infection, colons were removed and assessed for crypt hyperplasia, histology by light microscopy, bacterial colonization by immunofluorescence, and A/E lesion formation by electron microscopy. Prophylactic administration of B. breve did not prevent C. rodentium colonization or A/E lesion formation. However, this treatment did alter C. rodentium distribution within the large intestine and significantly reduced colonic crypt hyperplasia at the peak of bacterial infection. These results show that B. breve could not competitively exclude C. rodentium, but reduced pathogen-induced colonic inflammation.

  2. The diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients: A systematic review and diagnostic meta-analysis.

    PubMed

    Yoon, Hee Mang; Suh, Chong Hyun; Cho, Young Ah; Kim, Jeong Rye; Lee, Jin Seong; Jung, Ah Young; Kim, Jung Heon; Lee, Jeong-Yong; Kim, So Yeon

    2018-06-01

    To evaluate the diagnostic performance of reduced-dose CT for suspected appendicitis. A systematic search of the MEDLINE and EMBASE databases was carried out through to 10 January 2017. Studies evaluating the diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients were selected. Pooled summary estimates of sensitivity and specificity were calculated using hierarchical logistic regression modelling. Meta-regression was performed. Fourteen original articles with a total of 3,262 patients were included. For all studies using reduced-dose CT, the summary sensitivity was 96 % (95 % CI 93-98) with a summary specificity of 94 % (95 % CI 92-95). For the 11 studies providing a head-to-head comparison between reduced-dose CT and standard-dose CT, reduced-dose CT demonstrated a comparable summary sensitivity of 96 % (95 % CI 91-98) and specificity of 94 % (95 % CI 93-96) without any significant differences (p=.41). In meta-regression, there were no significant factors affecting the heterogeneity. The median effective radiation dose of the reduced-dose CT was 1.8 mSv (1.46-4.16 mSv), which was a 78 % reduction in effective radiation dose compared to the standard-dose CT. Reduced-dose CT shows excellent diagnostic performance for suspected appendicitis. • Reduced-dose CT shows excellent diagnostic performance for evaluating suspected appendicitis. • Reduced-dose CT has a comparable diagnostic performance to standard-dose CT. • Median effective radiation dose of reduced-dose CT was 1.8 mSv (1.46-4.16). • Reduced-dose CT achieved a 78 % dose reduction compared to standard-dose CT.

  3. Digital Optical Circuit Technology.

    DTIC Science & Technology

    1985-03-01

    ordinateurs ct des syst~mcs de diffusion de donn’es qui soient I la fois numcriques, entierement optiques. tres rapides etI I’abri des interferences et des...F.A.Hopf SESSION 11 - OPTICAL LOGIC PROSPECTS FOR PARALLEL NONLINEAR OPTICAL SIGNAL PROCESSING USING GaAs ETALONS AND ZnS INTERFERENCE FILTERS by...talks 1, 8, and 9) interference filters for room-temperature parallel processing. If one imposes a maximum heat load of 100 W/cm 2 , consistent with

  4. Micro-CT based modelling for characterising injection-moulded porous titanium implants.

    PubMed

    Chen, Junning; Chen, Liangjian; Chang, Che-Cheng; Zhang, Zhongpu; Li, Wei; Swain, Michael V; Li, Qing

    2017-01-01

    Design of prosthetic implants to ensure rapid and stable osseointegration remains a significant challenge, and continuous efforts have been directed to new implant materials, structures and morphology. This paper aims to develop and characterise a porous titanium dental implant fabricated by metallic powder injection-moulding. The surface morphology of the specimens was first examined with a scanning electron microscope (SEM), followed by microscopic computerised tomography (μ-CT) scanning to capture its 3D microscopic features non-destructively. The nature of porosity and pore sizes were determined statistically. A homogenisation technique based on the Hills-energy theorem was adopted to evaluate its directional elastic moduli, and the conservation of mass theorem was employed to quantify the oxygen diffusivity for bio-transportation feature. This porous medium was found to have pore sizes varying from 50 to 400 µm and the average porosity of 46.90 ± 1.83%. The anisotropic principal elastic moduli were found fairly close to the upper range of cortical bone, and the directional diffusivities could potentially enable radial osseous tissue ingrowth and vascularisation. This porous titanium successfully reduces the elastic modulus mismatch between implant and bone for dental and orthopaedic applications, and provides improved capacity for transporting oxygen, nutrient and waste for pre-vascular network formation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Testing Mechanisms and Scales of Equilibrium Using Textural and Compositional Analysis of Porphyroblasts in Rocks with Heterogeneous Garnet Distributions

    NASA Astrophysics Data System (ADS)

    Ruthven, R. C.; Ketcham, R. A.; Kelly, E. D.

    2015-12-01

    Three-dimensional textural analysis of garnet porphyroblasts and electron microprobe analyses can, in concert, be used to pose novel tests that challenge and ultimately increase our understanding of metamorphic crystallization mechanisms. Statistical analysis of high-resolution X-ray computed tomography (CT) data of garnet porphyroblasts tells us the degree of ordering or randomness of garnets, which can be used to distinguish the rate-limiting factors behind their nucleation and growth. Electron microprobe data for cores, rims, and core-to-rim traverses are used as proxies to ascertain porphyroblast nucleation and growth rates, and the evolution of sample composition during crystallization. MnO concentrations in garnet cores serve as a proxy for the relative timing of nucleation, and rim concentrations test the hypothesis that MnO is in equilibrium sample-wide during the final stages of crystallization, and that concentrations have not been greatly altered by intracrystalline diffusion. Crystal size distributions combined with compositional data can be used to quantify the evolution of nucleation rates and sample composition during crystallization. This study focuses on quartzite schists from the Picuris Mountains with heterogeneous garnet distributions consisting of dense and sparse layers. 3D data shows that the sparse layers have smaller, less euhedral garnets, and petrographic observations show that sparse layers have more quartz and less mica than dense layers. Previous studies on rocks with homogeneously distributed garnet have shown that crystallization rates are diffusion-controlled, meaning that they are limited by diffusion of nutrients to growth and nucleation sites. This research extends this analysis to heterogeneous rocks to determine nucleation and growth rates, and test the assumption of rock-wide equilibrium for some major elements, among a set of compositionally distinct domains evolving in mm- to cm-scale proximity under identical P-T conditions.

  6. Effects of cholera toxin on human colon carcinoma cell lines.

    PubMed

    Barkla, D H; Whitehead, R H; Hayward, I P

    1992-10-01

    This study reports on changes in morphology and membrane transport in 5 human colon carcinoma cell lines treated with cholera toxin (CT). Three of the cell lines that grew as monolayers (LIM 1215, LIM 1899, LIM 2099) and 1 that grew as floating clumps (LIM 2408) did not show morphological changes after CT treatment. However, cell line LIM 1863 that grows as floating "crypt-like" organoids showed rapid and distinctive changes in morphology and membrane transport after CT treatment. At 1 and 6 hrs after CT treatment, light and transmission electron microscopy revealed rapid dilatation of the central lumen of organoids and the appearance of 2 populations of apical vesicular inclusions. The first population was unusual in being non-membrane bound and limited by fuzzy filamentous material. The second population was membrane bound. Scanning electron microscopy at 1-6 hr after CT treatment showed swelling and loss of surface microvilli on some, but not all, cells. At 24 hr after CT treatment the majority of organoids showed evidence of fluid accumulation and small apical vesicles coalesced to form large single vacuoles that obliterated normal cell morphology. By 48 hr, continued swelling produced extreme attenuation of the plasma membrane with cells taking on an "endothelial cell-like" appearance. The response to CT was dose-dependent. Uptake studies using 86Rubidium and blocking studies using ouabain and amiloride indicated that CT is acting on the Na+/K+ ATPase membrane pump to cause the increased fluid uptake by LIM 1863 cells. This study is the first to report specific morphological changes in intestine-derived cells in response to CT.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Recurrent Scapular Metastasis From Hepatoblastoma Shown on FDG PET/CT and F-DOPA PET/CT.

    PubMed

    Zhang, Bing; He, Qiao; Shi, Xinchong; Wang, Xiaoyan; Zhang, Xiangsong

    2017-10-01

    We report the case of a 4-year-old girl with a biochemical relapse (plasma α-fetoprotein of 57,987.6 μg/L) after hepatoblastoma and extrahepatic metastases removal and adjuvant chemotherapy. Abdominal ultrasound, CT, and MRI failed to determine the site of recurrence. F-FDG PET/CT showed increased activity in the region of left scapula and adjacent soft tissue, which was incorrectly interpreted as the postoperative repair or inflammatory change. F-DOPA PET/CT showed increased activity and noticeable progressed lesion in the same place. Finally, the left scapula was identified as the site of recurrent metastasis from hepatoblastoma by pathological examination.

  8. Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.

    PubMed

    Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan

    2017-12-01

    To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p < 0.05). All three sealers presented less void volume in the apical third; however, higher void volumes were observed in the apical and coronal thirds in AH Plus using micro-CT (p < 0.05), while nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p < 0.05). Bioactive sealers showed higher root filling rate, lower incidence rate of voids, void fraction and void volume than AH Plus under nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.

  9. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities.

    PubMed

    Lechuga, Lawrence; Weidlich, Georg A

    2016-09-12

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient.

  10. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities

    PubMed Central

    Weidlich, Georg A.

    2016-01-01

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities—fan beam and cone beam—was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient. PMID:27752404

  11. SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site.

    PubMed

    Hirschmann, Michael T; Mathis, Dominic; Rasch, Helmut; Amsler, Felix; Friederich, Niklaus F; Arnold, Markus P

    2013-02-01

    SPECT/CT is a hybrid imaging modality, which combines a 3D scintigraphy (SPECT) and a conventional computerised tomography (CT). SPECT/CT allows accurate anatomical localisation of metabolic tracer activity. It allows the correlation of surgical factors such as tunnel position and orientation with mechanical alignment, clinical outcome and biological factors. The purpose of this study was to investigate whether the SPECT/CT tracer uptake (intensity and distribution) correlates with the stability and laxity of the knee joint and the position and orientation of the tibial and femoral tunnels in patients after anterior cruciate ligament (ACL) reconstruction. A consecutive series of knees (n=66), with symptoms of pain and/or instability after ACL reconstruction were prospectively evaluated using clinical examination and 99mTc-HDP-SPECT/CT. Clinical laxity testing was performed using the Rolimeter (Ormed, Freiburg, Germany) including Lachman testing (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), anterior drawer test (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), pivot shift test (positive versus negative) and patient-based subjective instability (yes versus no). For analysis of SPECT/CT tracer uptake a previously validated SPECT/CT localisation scheme consisting of 17 tibial, nine femoral and four patellar regions on standardised axial, coronal, and sagittal slices was used. The tracer activity on SPECT/CT was localised and recorded using a 3D volumetric and quantitative analysis software. Mean, standard deviation, minimum and maximum of grading for each area of the localisation scheme were recorded. The position and orientation of the tibial and femoral tunnel was assessed using a previously published method on 3D-CT. Correlation of instability, pivot shift as well as clinical laxity testing with 99mTc-HDP-SPECT/CT tracer uptake intensity and distribution showed no significant correlation. 99mTc-HDP-SPECT/CT tracer uptake correlated significantly with the position and orientation of the ACL graft. A more horizontal femoral graft position showed significantly increased tracer uptake within the superior and posterior femoral regions. A more posteriorly-placed femoral insertion site showed significantly more tracer uptake within the femoral and tibial tunnel regions. A more vertical or a less medial tibial tunnel orientation showed significant increased uptake within the tibial and femoral tunnel regions. A more anterior tibial tunnel position showed significantly more tracer uptake in the femoral and tibial tunnel regions as well as the entire tibiofemoral joint. SPECT/CT tracer uptake intensity and distribution showed a significant correlation with the femoral and tibial tunnel position and orientation in patients with symptomatic knees after ACL reconstruction. No correlation was found with stability or clinical laxity. SPECT/CT tracer uptake distribution has the potential to give us important information on joint homeostasis and remodelling after ACL reconstruction. It might help to predict ACL graft failure and improve our surgical ACL reconstruction technique in finding the optimal tunnel and graft position and orientation.

  12. Improved visual delineation of the intimal flap in Stanford type A and B dissections at 3rd generation dual-source high-pitch CT angiography.

    PubMed

    Beeres, Martin; Bucher, Andreas M; Wichmann, Julian L; Frellesen, Claudia; Scholtz, Jan E; Albrecht, Moritz; Bodelle, Boris; Nour-Eldin, Nour-Eldin A; Lee, Clara; Kaup, Moritz; Vogl, Thomas J; Gruber-Rouh, Tatjana

    2016-07-01

    Evaluation of the intimal flap visibility comparing 2nd and 3rd generation dual-source high-pitch CT. Twenty-five consecutive patients with aortic dissection underwent CT angiography on a second and third generation dual-source CT scanner using prospective ECG-gated high-pitch dual-source CT acquisition mode. Contrast material, saline flush and flow rate were kept equal for optimum comparability. The visibility of the intimal flap as well as the delineation of the different vascular structures was evaluated. In 3rd generation dual-source high-pitch CT we could show a significant improvement of intimal flap visibility in aortic dissection. Especially, the far end of the dissection membrane could be better evaluated in 3rd generation high-pitch CT, reaching statistical significance (P < 0.01). 3rd Generation high-pitch CT angiography shows a better delineation of the aortic intimal flap in a small patient cohort, especially in the far ends of the dissection membrane. This might be due to higher tube power in this CT generation. However, to generalise these findings larger trials are needed.

  13. Radiotherapy treatment planning: benefits of CT-MR image registration and fusion in tumor volume delineation.

    PubMed

    Djan, Igor; Petrović, Borislava; Erak, Marko; Nikolić, Ivan; Lucić, Silvija

    2013-08-01

    Development of imaging techniques, computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET), made great impact on radiotherapy treatment planning by improving the localization of target volumes. Improved localization allows better local control of tumor volumes, but also minimizes geographical misses. Mutual information is obtained by registration and fusion of images achieved manually or automatically. The aim of this study was to validate the CT-MRI image fusion method and compare delineation obtained by CT versus CT-MRI image fusion. The image fusion software (XIO CMS 4.50.0) was applied to delineate 16 patients. The patients were scanned on CT and MRI in the treatment position within an immobilization device before the initial treatment. The gross tumor volume (GTV) and clinical target volume (CTV) were delineated on CT alone and on CT+MRI images consecutively and image fusion was obtained. Image fusion showed that CTV delineated on a CT image study set is mainly inadequate for treatment planning, in comparison with CTV delineated on CT-MRI fused image study set. Fusion of different modalities enables the most accurate target volume delineation. This study shows that registration and image fusion allows precise target localization in terms of GTV and CTV and local disease control.

  14. SU-E-J-149: Establishing the Relationship Between Pre-Treatment Lung Ventilation, Dose, and Toxicity Outcome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mistry, N; D'Souza, W; Sornsen de Koste, J

    2014-06-01

    Purpose: Recently, there has been an interest in incorporating functional information in treatment planning especially in thoracic tumors. The rationale is that healthy lung regions need to be spared from radiation if possible to help achieve better control on toxicity. However, it is still unclear whether high functioning regions need to be spared or have more capacity to deal with the excessive radiation as compared to the compromised regions of the lung. Our goal with this work is to establish the tools by which we can establish a relationship between pre-treatment lung function, dose, and radiographic outcomes of lung toxicity.more » Methods: Treatment planning was performed using a single phase of a 4DCT scan, and follow-up anatomical CT scans were performed every 3 months for most patients. In this study, we developed the pipeline of tools needed to analyze such a large dataset, while trying to establish a relationship between function, dose, and outcome. Pre-treatment lung function was evaluated using a recently published technique that evaluates Fractional Regional Ventilation (FRV). All images including the FRV map and the individual follow-up anatomical CT images were all spatially matched to the planning CT using a diffusion based Demons image registration algorithm. Change in HU value was used as a metric to capture the effects of lung toxicity. To validate the findings, a radiologist evaluated the follow-up anatomical CT images and scored lung toxicity. Results: Initial experience in 1 patient shows a relationship between the pre-treatment lung function, dose and toxicity outcome. The results are also correlated to the findings by the radiologist who was blinded to the analysis or dose. Conclusion: The pipeline we have established to study this enables future studies in large retrospective studies. However, the tools are dependent on the fidelity of 4DCT reconstruction for accurate evaluation of regional ventilation. Patent Pending for the technique presented in this work to evaluate FRV incorporating mass correction.« less

  15. Utility of CT in the diagnosis and management of small-bowel obstruction in children.

    PubMed

    Wang, Qiuyan; Chavhan, Govind B; Babyn, Paul S; Tomlinson, George; Langer, Jacob C

    2012-12-01

    CT is often used in the diagnosis and management of small-bowel obstruction in children. To determine sensitivity of CT in delineating presence, site and cause of small-bowel obstruction in children. We retrospectively reviewed the CT scans of 47 children with surgically proven small-bowel obstruction. We noted any findings of obstruction and the site and cause of obstruction. Presence, absence or equivocal findings of bowel obstruction on abdominal radiographs performed prior to CT were also noted. We reviewed patient charts for clinical details and surgical findings, including bowel resection. Statistical analysis was performed using Fisher exact test to determine which CT findings might predict bowel resection. CT correctly diagnosed small-bowel obstruction in 43/47 (91.5%) cases. CT correctly indicated site of obstruction in 37/47 (78.7%) cases and cause of obstruction in 32/47 (68.1%) cases. Small-bowel feces sign was significantly associated with bowel resection at surgery (P = 0.0091). No other CT finding was predictive of bowel resection. Out of 41 children who had abdominal radiographs before CT, 29 (70.7%) showed unequivocal obstruction, six (14.6%) showed equivocal findings and six (14.6%) were unremarkable. CT is highly sensitive in diagnosing small-bowel obstruction in children and is helpful in determining the presence of small-bowel obstruction in many clinically suspected cases with equivocal or normal plain radiographs. CT also helps to determine the site and cause of the obstruction with good sensitivity.

  16. Sarcoidosis: correlation of pulmonary parenchymal pattern at CT with results of pulmonary function tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergin, C.J.; Bell, D.Y.; Coblentz, C.L.

    1989-06-01

    The appearances of the lungs on radiographs and computed tomographic (CT) scans were correlated with degree of uptake on gallium scans and results of pulmonary function tests (PFTs) in 27 patients with sarcoidosis. CT scans were evaluated both qualitatively and quantitatively. Patients were divided into five categories on the basis of the pattern of abnormality at CT: 1 = normal (n = 4); 2 = segmental air-space disease (n = 4); 3 = spherical (alveolar) masslike opacities (n = 4); 4 = multiple, discrete, small nodules (n = 6); and 5 = distortion of parenchymal structures (fibrotic end-stage sarcoidosis) (nmore » = 9). The percentage of the volume judged to be abnormal (CT grade) was correlated with PFT results for each CT and radiographic category. CT grades were also correlated with gallium scanning results and percentage of lymphocytes recovered from bronchoalveolar lavage (BAL). Patients in CT categories 1 and 2 had normal lung function, those in category 3 had mild functional impairment, and those in categories 4 and 5 showed moderate to severe dysfunction. The overall CT grade correlated well with PFT results expressed as a percentage of the predicted value. In five patients, CT scans showed extensive parenchymal disease not seen on radiographs. CT grades did not correlate with the results of gallium scanning or BAL lymphocytes. The authors conclude that patterns of parenchymal sarcoidosis seen at CT correlate with the PFT results and can be used to indicate respiratory impairment.« less

  17. Clinical characteristics and computed tomography findings of pulmonary toxoplasmosis after hematopoietic stem cell transplantation.

    PubMed

    Sumi, Masahiko; Norose, Kazumi; Hikosaka, Kenji; Kaiume, Hiroko; Takeda, Wataru; Kirihara, Takehiko; Kurihara, Taro; Sato, Keijiro; Ueki, Toshimitsu; Hiroshima, Yuki; Kuraishi, Hiroshi; Watanabe, Masahide; Kobayashi, Hikaru

    2016-12-01

    The prognosis of pulmonary toxoplasmosis, including disseminated toxoplasmosis involving the lungs, following hematopoietic stem cell transplantation (HSCT) is extremely poor due to the difficulties associated with early diagnosis and the rapidly progressive deterioration of multiorgan function. In our institution, we identified nine cases of toxoplasmosis, representing incidences of 2.2 and 19.6 % among all HSCT recipients and seropositive HSCT recipients, respectively. Of the patients with toxoplasmosis, six had pulmonary toxoplasmosis. Chest computed tomography (CT) findings revealed centrilobular, patchy ground-glass opacities (n = 3), diffuse ground-glass opacities (n = 2), ground-glass opacities with septal thickening (n = 1), and marked pleural effusion (n = 1). All cases died, except for one with suspected pulmonary toxoplasmosis who was diagnosed by a polymerase chain reaction assay 2 days after the onset of symptoms. In pulmonary toxoplasmosis, CT findings are non-specific and may mimic pulmonary congestion, atypical pneumonia, viral pneumonitis, and bronchopneumonia. Early diagnosis and treatment is crucial for overcoming this serious infectious complication. Pulmonary toxoplasmosis should be considered during differential diagnosis in a recipient with otherwise unexplained signs of infection and CT findings with ground-glass opacities, regardless of the distribution.

  18. Dual-energy CT and ceramic or titanium prostheses material reduce CT artifacts and provide superior image quality of total knee arthroplasty.

    PubMed

    Kasparek, Maximilian F; Töpker, Michael; Lazar, Mathias; Weber, Michael; Kasparek, Michael; Mang, Thomas; Apfaltrer, Paul; Kubista, Bernd; Windhager, Reinhard; Ringl, Helmut

    2018-06-07

    To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.

  19. Docking, characterization and investigation of β-cyclodextrin complexed with citronellal, a monoterpene present in the essential oil of Cymbopogon species, as an anti-hyperalgesic agent in chronic muscle pain model.

    PubMed

    Santos, Priscila L; Brito, Renan G; Oliveira, Marlange A; Quintans, Jullyana S S; Guimarães, Adriana G; Santos, Márcio R V; Menezes, Paula P; Serafini, Mairim R; Menezes, Irwin R A; Coutinho, Henrique D M; Araújo, Adriano A S; Quintans-Júnior, Lucindo J

    2016-08-15

    Citronellal (CT) is a monoterpene with antinociceptive acute effect. β-Cyclodextrin (βCD) has enhanced the analgesic effect of various substances. To evaluate the effect of CT both complexed in β-cyclodextrin (CT-βCD) and non-complexed, in a chronic muscle pain model (CMP) in mice. The complex containing CT in βCD was obtained and characterized in the laboratory. The anti-hyperalgesic effect of CT and CT-βCD was evaluated in a pre-clinical in vivo study in a murine CMP. The complex was characterized through differential scanning calorimetry, derivative thermogravimetry, moisture determination, infrared spectroscopy and scanning electron microscopy. Male Swiss mice were pre-treated with CT (50mg/kg, po), CT-βCD (50mg/kg, po), vehicle (isotonic saline, po) or standard drug (tramadol4 mg/kg, ip). 60 min after the treatment and then each 1h, the mechanic hyperalgesia was evaluated to obtain the time effect. In addition, the muscle strength using grip strength meter and hyperalgesia were also performed daily, for 7 days. We assessed by immunofluorescence for Fos protein on brains and spinal cords of mice. The involvement of the CT with the glutamatergic system was studied with molecular docking. All characterization methods showed the CT-βCD complexation. CT-induced anti-hyperalgesic effect lasted until 6h (p <0.001) while CT-βCD lasted until 8h (p <0.001vs vehicle and p <0.001vs CT from the 6th h). CT-βCD reduced mechanical hyperalgesia on all days of treatment (p <0.05), without changing muscle strength. Periaqueductal gray (p <0.01) and rostroventromedular area (p <0.05) showed significant increase in the Fos protein expression while in the spinal cord, there was a reduction (p <0.001). CT showed favorable energy binding (-5.6 and -6.1) to GluR2-S1S2J protein based in the docking score function. We can suggest that βCD improved the anti-hyperalgesic effect of CT, and that effect seems to involve the descending pain-inhibitory mechanisms, with a possible interaction of the glutamate receptors, which are considered as promising molecules for the management of chronic pain such as CMP. Copyright © 2016 Elsevier GmbH. All rights reserved.

  20. Circadian Periods of Sensitivity for Ramelteon on the onset of Running-wheel Activity and the Peak of Suprachiasmatic Nucleus Neuronal Firing Rhythms in C3H/HeN Mice

    PubMed Central

    Rawashdeh, Oliver; Hudson, Randall L.; Stepien, Iwona; Dubocovich, Margarita L.

    2016-01-01

    Ramelteon, an MT1/MT2 melatonin receptor agonist, is used for the treatment of sleep-onset insomnia and circadian sleep disorders. Ramelteon phase shifts circadian rhythms in rodents and humans when given at the end of the subjective day; however, its efficacy at other circadian times is not known. Here, the authors determined in C3H/ HeN mice the maximal circadian sensitivity for ramelteon in vivo on the onset of circadian running-wheel activity rhythms, and in vitro on the peak of circadian rhythm of neuronal firing in suprachiasmatic nucleus (SCN) brain slices. The phase response curve (PRC) for ramelteon (90 μg/mouse, subcutaneous [sc]) on circadian wheel-activity rhythms shows maximal sensitivity during the late mid to end of the subjective day, between CT8 and CT12 (phase advance), and late subjective night and early subjective day, between CT20 and CT2 (phase delay), using a 3-day-pulse treatment regimen in C3H/HeN mice. The PRC for ramelteon resembles that for melatonin in C3H/ HeN mice, showing the same magnitude of maximal shifts at CT10 and CT2, except that the range of sensitivity for ramelteon (CT8–CT12) during the subjective day is broader. Furthermore, in SCN brain slices in vitro, ramelteon (10 pM) administered at CT10 phase advances (5.6 ± 0.29 h, n = 3) and at CT2 phase delays (−3.2 ± 0.12 h, n = 6) the peak of circadian rhythm of neuronal firing, with the shifts being significantly larger than those induced by melatonin (10 pM) at the same circadian times (CT10: 2.7 ± 0.15 h, n = 4, p < .05; CT2: −1.13 ± 0.08 h, n = 6, p < .001, respectively). The phase shifts induced by both melatonin and ramelteon in the SCN brain slice at either CT10 or CT2 corresponded with the period of sensitivity observed in vivo. In conclusion, melatonin and ramelteon showed identical periods of circadian sensitivity at CT10 (advance) and CT2 (delay) to shift the onset of circadian activity rhythms in vivo and the peak of SCN neuronal firing rhythms in vitro. PMID:21182402

  1. Systematic Review and Meta-Analysis of CT Features for Differentiating Complicated and Uncomplicated Appendicitis.

    PubMed

    Kim, Hae Young; Park, Ji Hoon; Lee, Yoon Jin; Lee, Sung Soo; Jeon, Jong-June; Lee, Kyoung Ho

    2018-04-01

    Purpose To perform a systematic review and meta-analysis to identify computed tomographic (CT) features for differentiating complicated appendicitis in patients suspected of having appendicitis and to summarize their diagnostic accuracy. Materials and Methods Studies on diagnostic accuracy of CT features for differentiating complicated appendicitis (perforated or gangrenous appendicitis) in patients suspected of having appendicitis were searched in Ovid-MEDLINE, EMBASE, and the Cochrane Library. Overlapping descriptors used in different studies to denote the same image finding were subsumed under a single CT feature. Pooled diagnostic accuracy of the CT features was calculated by using a bivariate random effects model. CT features with pooled diagnostic odds ratios with 95% confidence intervals not including 1 were considered as informative. Results Twenty-three studies were included, and 184 overlapping descriptors for various CT findings were subsumed under 14 features. Of these, 10 features were informative for complicated appendicitis. There was a general tendency for these features to show relatively high specificity but low sensitivity. Extraluminal appendicolith, abscess, appendiceal wall enhancement defect, extraluminal air, ileus, periappendiceal fluid collection, ascites, intraluminal air, and intraluminal appendicolith showed pooled specificity greater than 70% (range, 74%-100%), but sensitivity was limited (range, 14%-59%). Periappendiceal fat stranding was the only feature that showed high sensitivity (94%; 95% confidence interval: 86%, 98%) but low specificity (40%; 95% confidence interval, 23%, 60%). Conclusion Ten informative CT features for differentiating complicated appendicitis were identified in this study, nine of which showed high specificity, but low sensitivity. © RSNA, 2017 Online supplemental material is available for this article.

  2. The use of 99mTc-HYNIC-TOC and 18F-FDG PET/CT in the evaluation of duodenal neuroendocrine tumor with atypical and extensive metastasis responding dramatically to a single fraction of PRRT with 177Lu-DOTATATE.

    PubMed

    Basu, Sandip; Abhyankar, Amit

    2014-12-01

    This report describes a case of extensive diffuse bone marrow involvement with bilateral breast metastases from duodenal neuroendocrine tumor giving rise to a superscan-like appearance on somatostatin receptor-targeted (99m)Tc-hydrazinonicotinamide-TOC scintigraphy. The metastatic lesions demonstrated partial concordance with (18)F-FDG PET/CT findings, signifying varying tumor biology and heterogeneity among metastatic lesions in the same individual, as illustrated with a dual-tracer approach. There was a dramatic symptomatic and biochemical response and better health-related quality of life with a single fraction of peptide receptor radionuclide therapy with (177)Lu-DOTATATE, and radiologically there was stable disease at that point. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. Multicystic mesothelioma--a rare case of ascites: case report.

    PubMed

    Manuc, M; Lamatic, C; Pop, C; Dobrea, C; Becheanu, G; Grasu, M; Iosif, D; Diculescu, M

    2007-01-01

    We present the case of a 37-year-old male, admitted to our clinic with abdominal tenderness, right supraclavicular tumour, and ascites. The presence of ascites was incidentally reported 6 years before, but no other evaluation was done at that moment or during this period. Abdominal ultrasound and CT scan revealed moderate ascites, perivascular adenopathies, and multiple abdominal cystic lesions, while thoracic CT scan revealed the same lesions in mediastinum. Laboratory data were within normal limits, including the tumoral markers, and the tests for hydatid cysts. A biopsy from the right supraclavicular nodule was performed, and based on usual and immunohistochemical stains (calretinin, mesotheline, CK 5/6, CK 7, CK18 diffusely positive in mesothelial cells, and CEA -M, bcl-2 and vimentin negative), suggested the diagnosis of mesothelioma. Based on these results, the diagnosis of "multicystic mesothelioma" was made. The patient was referred for surgery.

  4. Importance of correctly interpreting magnetic resonance imaging to diagnose posterior reversible encephalopathy syndrome associated with HELLP syndrome: a case report.

    PubMed

    Tetsuka, Syuichi; Nonaka, Hiroaki

    2017-05-25

    Severe haemolysis, elevated liver enzyme levels, and low platelet count (HELLP) syndrome in pregnancy are possible underlying trigger factors for posterior reversible encephalopathy syndrome (PRES). Magnetic resonance imaging (MRI) shows diffuse signal abnormalities involving the subcortical white matter in the parieto-occipital lobes. Although the diagnosis of RPES was clearly established by the distinctive reversibility of clinical and radiological abnormalities, it is difficult to distinguish from differential diagnosis. Thus, it is important to correctly interpret MRI. We describe a case of HELLP syndrome with PRES. A 38-year-old pregnant woman was admitted to our hospital as an emergency case with a complaint of upper abdominal pain and headache at 29 weeks of pregnancy and the development of HELLP syndrome. An emergency caesarean section was immediately performed. After the operation, the patient received intravenous corticosteroids, and her blood pressure was controlled. Thereafter, she showed an altered mental status. MRI showed hypersignal intense lesions in the cortical and subcortical white matter in the occipital lobes, basal ganglia and callosal splenium in both the fluid-attenuated inversion recovery (FLAIR) sequence and apparent diffusion coefficient (ADC), but these lesions were not recognized in diffusion-weighted imaging (DWI). These images were suggestive of PRES. The patient was kept in the hospital and received the appropriate treatment, after which the patient's level of consciousness improved and all laboratory tests and imaging examinations returned normal. The MRI findings were useful for the prompt diagnosis of PRES, characterized by hypersignals in FLAIR and ADC, but not in DWI. Additionally, there was an "atypical" MRI appearance of basal ganglial and callosal splenial involvement in this case, which may mistakenly lead clinicians to diagnose other aetiologies than typical PRES. It is considered that vasogenic oedema is the main pathology of PRES according to the MRI image findings. MRI is the gold standard for diagnosing PRES because it can provide information about cerebral involvement earlier than CT; further, it can be a useful tool in the differential diagnosis. This technique facilitated the prompt diagnosis and treatment of the said patient, ultimately resulting in a good outcome.

  5. Adenocarcinoma Prostate With Neuroendocrine Differentiation: Potential Utility of 18F-FDG PET/CT and 68Ga-DOTANOC PET/CT Over 68Ga-PSMA PET/CT.

    PubMed

    Parida, Girish Kumar; Tripathy, Sarthak; Datta Gupta, Shreya; Singhal, Abhinav; Kumar, Rakesh; Bal, Chandrasekhar; Shamim, Shamim Ahmed

    2018-04-01

    Ga-PSMA PET/CT is the upcoming imaging modality for staging, restaging and response assessment of prostate cancer. However, due to neuroendocrine differentiation in some of patients with prostate cancer, they express somatostatin receptors instead of prostate specific membrane antigen. This can be exploited and other modalities like Ga-DOTANOC PET/CT and F-FDG PET/CT should be used in such cases for guiding management. We hereby discuss a similar case of 67-year-old man of adenocarcinoma prostate with neuroendocrine differentiation, which shows the potential pitfall of Ga-PSMA PET/CT imaging and benefit of Ga-DOTANOC PET/CT and F-FDG PET/CT in such cases.

  6. Differential diagnosis of primary nasopharyngeal lymphoma and nasopharyngeal carcinoma focusing on CT, MRI, and PET/CT.

    PubMed

    Cho, Kyu-Sup; Kang, Dae-Woon; Kim, Hak-Jin; Lee, Jong-Kil; Roh, Hwan-Jung

    2012-04-01

    No study has done a comparative analysis of radiologic imaging findings between primary nasopharyngeal lymphoma (PNL) and nasopharyngeal carcinoma (NPC). The purpose of this study was to analyze computed tomography (CT) and magnetic resonance (MR) images and to evaluate the maximum standardized uptake value (SUV max) of positron emission tomography (PET)/CT between PNL and NPC, knowing the imaging features that distinguish PNL from NPC. Cross-sectional study. University tertiary care facility. The authors analyzed the features on CT, MR imaging, and PET/CT of 16 patients diagnosed with PNL and 32 patients diagnosed with NPC histopathologically. Patients with PNL had a larger tumor volume and showed symmetry of tumor shape than did patients with NPC. Patients with PNL also had higher tumor homogeneity than NPC patients on CT, T2-weighted, and postcontrast MR images. All PNL patients showed a high degree of enhancement without invasion to the adjacent deep structure. The involvement of the Waldeyer ring was significantly higher in PNL patients. Cervical and retropharyngeal lymphadenopathy and PET/CT SUV max showed no significant difference between PNL and NPC. If the images present a bulky, symmetric nasopharyngeal mass with marked homogeneity, a high degree of enhancement, and a higher Waldeyer ring involvement combined with no invasion into the deep structure, PNL should be considered over NPC.

  7. Infrequent and low expression of cancer-testis antigens located on the X chromosome in colorectal cancer: implications for immunotherapy in South African populations.

    PubMed

    Dakshinamurthy, Amirtha Ganesh; Ramesar, Rajkumar; Goldberg, Paul; Blackburn, Jonathan M

    2008-11-01

    Cancer-testis (CT) antigens are a group of tumor antigens that are expressed in the testis and aberrantly in cancerous tissue but not in somatic tissues. The testis is an immune-privileged site because of the presence of a blood-testis barrier; as a result, CT antigens are considered to be essentially tumor specific and are attractive targets for immunotherapy. CT antigens are classified as the CT-X and the non-X CT antigens depending on the chromosomal location to which the genes are mapped. CT-X antigens are typically highly immunogenic and hence the first step towards tailored immunotherapy is to elucidate the expression profile of CT-X antigens in the respective tumors. In this study we investigated the expression profile of 16 CT-X antigen genes in 34 colorectal cancer (CRC) patients using reverse transcription-polymerase chain reaction. We observed that 12 of the 16 CT-X antigen genes studied did not show expression in any of the CRC samples analyzed. The other 4 CT-X antigen genes showed low frequency of expression and exhibited a highly variable expression profile when compared to other populations. Thus, our study forms the first report on the expression profile of CT-X antigen genes among CRC patients in the genetically diverse South African population. The results of our study suggest that genetic and ethnic variations in population might have a role in the expression of the CT-X antigen genes. Thus our results have significant implications for anti-CT antigen-based immunotherapy trials in this population.

  8. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, H; Barbee, D; Wang, W

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CTmore » for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.« less

  9. KENNEDY SPACE CENTER, FLA. - A closeup of crawler-transportation (CT) number 2 shows the new muffler system on the vehicle. The CT also recently underwent modifications to the cab. The CT is transporting a Mobile Launch Platform (MLP). The CT moves Space Shuttle vehicles, situated on the MLP, between the VAB and launch pad. Moving on four double-tracked crawlers, the CT uses a laser guidance system and a leveling system for the journey that keeps the top of a Space Shuttle vertical within plus- or minus-10 minutes of arc. The system enables the CT-MLP-Shuttle to negotiate the ramp leading to the launch pads and keep the load level. Unloaded, the CT weighs 6 million pounds. Seen on top of the MLP are two tail service masts that support the fluid, gas and electrical requirements of the orbiter’s liquid oxygen and liquid hydrogen aft umbilicals.

    NASA Image and Video Library

    2003-08-18

    KENNEDY SPACE CENTER, FLA. - A closeup of crawler-transportation (CT) number 2 shows the new muffler system on the vehicle. The CT also recently underwent modifications to the cab. The CT is transporting a Mobile Launch Platform (MLP). The CT moves Space Shuttle vehicles, situated on the MLP, between the VAB and launch pad. Moving on four double-tracked crawlers, the CT uses a laser guidance system and a leveling system for the journey that keeps the top of a Space Shuttle vertical within plus- or minus-10 minutes of arc. The system enables the CT-MLP-Shuttle to negotiate the ramp leading to the launch pads and keep the load level. Unloaded, the CT weighs 6 million pounds. Seen on top of the MLP are two tail service masts that support the fluid, gas and electrical requirements of the orbiter’s liquid oxygen and liquid hydrogen aft umbilicals.

  10. Staging and follow-up of lacrimal gland carcinomas by 18F-FDG PET/CT imaging.

    PubMed

    Tafti, Bashir Akhavan; Shaba, Wisam; Li, Yuxin; Yevdayev, Ella; Berenji, Gholam Reza

    2012-10-01

    A 74-year-old man with right eye proptosis, diplopia, and orbital discomfort for 3 to 4 months underwent biopsy, the specimen of which showed transitional cell carcinoma of the lacrimal gland. 18F-FDG PET/CT was also performed for staging purposes. Six months after orbital exenteration, a follow-up CT scan demonstrated soft tissue thickening along the nasal bridge but could not differentiate between postsurgical changes and cancer recurrence. A concurrent PET/CT scan did not show any evidence of abnormal metabolic activity, further emphasizing the higher accuracy of PET/CT in staging and restaging of head and neck cancers. An annual follow-up scan was still negative for active disease.

  11. Sinonasal haemangiopericytoma: histomorphology and differential diagnoses.

    PubMed

    Leow, Wei Qiang; Sng, Ivy

    2015-04-01

    A 39-year-old female presented with a fleshy nasal polyp occluding the left nasal cavity, associated with haemopurulent discharge. Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) scans of the paranasal cavities revealed a large polypoid tumour arising from the left middle turbinate and obstructing the left maxillary sinus ostium. However, no bony or intracranial involvement was identified. A biopsy revealed a tumour with small blue round cell morphology. The tumour cells showed diffuse strong membranous CD99 positivity and patchy CD34 positivity. Ancillary cytogenetic tests for the EWSR1 and SS18/SYT gene translocations were negative. In view of the non-invasive nature of the tumour and the low cell proliferative index (Ki-67) of 5%, a medial maxillectomy resection was performed. The resection revealed additional areas with spindle-cell morphology and focal haemangiopericytic vasculature. The tumour continued to show immunoreactivity to CD99 and CD34, as well as Smooth Muscle Actin (SMA) and Muscle Specific Actin (MSA). The overall findings are in keeping with a sinonasal haemangiopericytoma. With clear surgical resection margins, the patient is on routine follow-up and is currently disease-free.

  12. Pleuroperitoneal Mesothelioma: A Rare Entity on 18F-FDG PET/CT

    PubMed Central

    Sahoo, Manas Kumar; Mukherjee, Anirban; Girish; Parida, Kumar; Agarwal, Krishan Kant; Bal, Chandrasekhar; Tripathi, Madhavi; Das, Chandan Jyoti; Shamim, Shamim Ahmed

    2017-01-01

    Pleuroperitoneal mesothelioma is an extremely rare entity. Only few cases are reported worldwide. We hereby represent a case of pleural mesothelioma referred for F-18-Fluorodeoxyglucose positron emission tomography/computed tomography for response evaluation. Diffuse F-18-Fluorodeoxyglucose avid peritoneal and omental thickening noted which subsequently turned out to be mesothelial involvement on peritoneal biopsy. This case demonstrates the role of F-18-Fluorodeoxyglucose positron emission tomography/computed tomography in detecting other sites of involvement in case of malignant mesothelioma. PMID:28242997

  13. Spontaneous dural cavernous fistula in infancy.

    PubMed

    Johnson, Paul B; Lelli, Gary J; Khorsandi, Azita; Dellarocca, David A

    2010-01-01

    A 4-month-old boy presented with the sudden onset of proptosis and dilated episcleral veins. CT revealed an enlarged superior ophthalmic vein and diffusely thickened extraocular muscles. MRI and angiography confirmed a dural middle meningeal--cavernous sinus fistula. Embolization was performed leading to successful resolution of the patient's signs and symptoms. Spontaneous atraumatic arteriovenous cavernous fistulae in infancy are extremely rare, but should be included in the differential diagnosis of infants with orbital congestion. Appropriate treatment leads to prevention of amblyopia, glaucoma, and anisometropia.

  14. Hydrological fine-structure evolution as a proxy of water mass property changes in the Tyrrhenian Sea

    NASA Astrophysics Data System (ADS)

    Durante, Sara; Schroeder, Katrin; Sparnocchia, Stefania; Mazzei, Luca; Borghini, Mireno; Pierini, Stefano

    2017-04-01

    The variability of the Tyrrhenian basin water masses properties, as inferred by the evolution of the typical step-like profile of the water column, is analyzed from 2003 to 2016. The dataset contains hydrological time series obtained in two deep control stations at a depth of about 3500 m. The study follows the evolution of double diffusion processes (a coherent basin feature) that leads to well-defined and permanent staircases. In each profile, four main steps can be recognized between 400 m and 2500 m both in conservative temperature (CT) and absolute salinity (SA), the main one having a thickness of about 400 m. The Tyrrhenian Sea is a not particularly dynamic basin if compared with other areas of the Mediterranean Sea, yet the staircases show large hydrological and depth changes. In particular, an increase of CT and SA and an uplifting are observed in the second part of the time series. Such changes can be due to both internal and external forcing. To discern the nature of the forcing, a suitable method [1] has been applied to our case study. Changes in SA are found to be similar along both isobars and neutral surfaces, so they can be ascribed to an external forcing. On the other hand, the CT shows different trends along isobars and neutral surfaces: this suggests that internal forcing can play an important role. The new Western Mediterranean Deep Water formed in severe winters after 2004-2005 and later in the Gulf of Lion (during the so-called Western Mediterranean Transition [2]) is suggested to be an external forcing producing the observed variability. Oscillatory movements of the neutral surfaces can also be observed after 2010. Computation of heat and salt fluxes (both for the whole water column and for each single step) sheds light on the conservative character of hydrological parameters of the step-system. [1] Bindoff, N.L., McDougall, T.J., 1994. J. Phys. Oceanogr. 24, 1137-1152. [2] Schroeder, K., G. P.Gasparini, M. Tangherlini, and M. Astraldi, 2006. Geophys. Res. Lett., 33, L21607, doi:10.1029/2006GL027121.

  15. [Current practice in MR imaging of the liver].

    PubMed

    Kanematsu, M; Kondo, H; Matsuo, M; Hoshi, H

    2001-12-01

    MR imaging, which is able to evaluate T1- and T2-relaxation time, fat, hemorrhage, metal deposition, blood flow, perfusion, diffusion, and so on, has offered more information for the diagnosis of diffuse and focal hepatic diseases than CT. The spoiled-GRE sequence with high contrast resolution and ease of the aimed contrast capture derived from the k-space property, with the use of a phased-array multicoil, have remarkably increased the value of gadolinium-enhanced dynamic MR diagnosis of the liver. In recent years, the clinical use of ferumoxide has begun, and issues concerning the superiority or inferiority and combination of contrast media are being debated. This paper describes the value, role, and clinical practice of unenhanced, gadolinium-enhanced, and ferumoxide-enhanced MR imaging of the liver based on knowledge obtained in our institution, with some reference to the literature.

  16. Impact of Consolidation Radiation Therapy in Stage III-IV Diffuse Large B-cell Lymphoma With Negative Post-Chemotherapy Radiologic Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dorth, Jennifer A., E-mail: jennifer.dorth@duke.edu; Prosnitz, Leonard R.; Broadwater, Gloria

    2012-11-01

    Purpose: While consolidation radiation therapy (i.e., RT administered after chemotherapy) is routine treatment for patients with early-stage diffuse large B-cell lymphoma (DLBCL), the role of consolidation RT in stage III-IV DLBCL is controversial. Methods and Materials: Cases of patients with stage III-IV DLBCL treated from 1991 to 2009 at Duke University, who achieved a complete response to chemotherapy were reviewed. Clinical outcomes were calculated using the Kaplan-Meier method and were compared between patients who did and did not receive RT, using the log-rank test. A multivariate analysis was performed using Cox proportional hazards model. Results: Seventy-nine patients were identified. Chemotherapymore » (median, 6 cycles) consisted of anti-CD20 antibody rituximab combined with cyclophosphamide, doxorubicin, vincristine, and prednisone (R-CHOP; 65%); cyclophosphamide, doxorubicin, vincristine, and prednisone (CHOP; 22%); or other (13%). Post-chemotherapy imaging consisted of positron emission tomography (PET)/computed tomography (CT) (73%); gallium with CT (14%); or CT only (13%). Consolidation RT (median, 25 Gy) was given to involved sites of disease in 38 (48%) patients. Receipt of consolidation RT was associated with improved in-field control (92% vs. 69%, respectively, p = 0.028) and event-free survival (85% vs. 65%, respectively, p = 0.014) but no difference in overall survival (85% vs. 78%, respectively, p = 0.15) when compared to patients who did not receive consolidation RT. On multivariate analysis, no RT was predictive of increased risk of in-field failure (hazard ratio [HR], 8.01, p = 0.014) and worse event-free survival (HR, 4.3, p = 0.014). Conclusions: Patients with stage III-IV DLBCL who achieve negative post-chemotherapy imaging have improved in-field control and event-free survival with low-dose consolidation RT.« less

  17. MO-FG-BRA-08: A Preliminary Study of Gold Nanoparticles Enhanced Diffuse Optical Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, K; Dogan, N; Yang, Y

    2015-06-15

    Purpose: To develop an imaging method by using gold nanoparticles (GNP) to enhance diffuse optical tomography (DOT) for better tumor detection. Methods: Experiments were performed on a tissue-simulating cylindrical optical phantom (30mm diameter, 60mm length). The GNP used are gold nanorods (10nm diameter, 44nm length) with peak light absorption at 840nm. 0.085ml GNP colloid of 96nM concentration was loaded into a 6mm diameter cylindrical hole in the phantom. An 856nm laser beam (14mW) was used as light source to irradiate the phantom at multiple locations through rotating and elevating the phantom. A CCD camera captured the light transmission through themore » phantom for each irradiation with total 40 projections (8 rotation angles in 45degree steps and 5 elevations with 3mm apart). Cone beam CT of the phantom was used to generate the three-dimensional mesh for DOT reconstruction and to identify the true location of the GNP volume. A forward simulation was performed with known phantom optical properties to establish a relationship between the absorption coefficient and concentration of the GNP by matching the simulated and measured transmission. DOT image reconstruction was performed to restore the GNP within the phantom. In addition, a region-constrained reconstruction was performed by confining the solutions within the GNP volume detected from CT. Results: The position of the GNP volume was reconstructed with <2mm error. The reconstructed average GNP concentration within an identical volume was 104nM, 8% difference from the truth. When the CT was used as “a priori”, the reconstructed average GNP concentration was 239nM, about 2.5 times of the true concentration. Conclusion: This study is the first to demonstrate GNP enhanced DOT with phantom imaging. The GNP can be differentiated from their surrounding background. However, the reconstruction methods needs to be improved for better spatial and quantification accuracy.« less

  18. FDG PET/CT findings in acquired perforating dermatosis.

    PubMed

    Shinmura, Akiko; Abe, Koichiro; Baba, Shingo; Isoda, Takuro; Maruoka, Yasuhiro; Yasukawa, Fumiko; Kiryu, Hiromaro; Sasaki, Masayuki; Furue, Masutaka; Honda, Hiroshi

    2012-10-01

    Acquired perforating dermatosis (APD) is an uncommon cutaneous perforating disorder. We report a patient on hemodialysis who developed skin eruption and jaundice. He underwent FDG PET/CT under suspicion of biliary malignancies. PET/CT showed no significant abnormal uptake except of multiple FDG-avid nodules in the skin. The eruption he had was histopathologically diagnosed as APD by skin biopsy. His case suggests that APD should be considered as a differential diagnosis when multiple cutaneous FDG accumulations are found in a patient on hemodialysis. To the best of our knowledge, this is the first report showing the FDG PET/CT findings of APD.

  19. Bilateral lateral ventricular subependymoma with extensive multiplicity presenting with hemorrhage.

    PubMed

    Moinuddin, F M; Ikbar Khairunnisa, Novita; Hirano, Hirofumi; Hanada, Tomoko; Hiraki, Tsubasa; Kirishima, Mari; Kamimura, Kiyohisa; Arita, Kazunori

    2018-02-01

    This 48-year-old-man who had undergone right thyroid lobectomy for undifferentiated thyroid carcinoma nine years earlier developed generalized seizures. His cerebrospinal fluid was xanthochromic with elevation of total protein. Computed tomography (CT) showed mixed-density bilateral ventricular masses. Magnetic resonance imaging (MRI) revealed multiple nodules in both lateral ventricles; they were heterogeneously enhanced by gadolinium. Diffuse hyperintensity in the right medial temporal lobe and bilateral subependymal area was noted on fluid-attenuated inversion recovery images. Susceptibility-weighted imaging showed low intensity in the masses and cerebellar sulci suggesting hemorrhage and hemosiderin deposition. The preoperative diagnosis was disseminated malignant tumor with recurring hemorrhage. Histological examination of biopsy specimens showed clusters of cells with small uniform nuclei embedded in a dense fibrillary matrix of glial cells and microcystic degeneration. Pseudo-rosettes indicating ependymoma were absent. Microhemorrhages and hemosiderin deposits were noted. Immunohistochemically, the background fibrillary matrix and neoplastic cells were positive for glial fibrillary acidic protein. Mutated isocitrate dehydrogenase-1 was negative. The MIB-1 index was 1.5%. The tumor was pathologically diagnosed as subependymoma containing microhemorrhages and hemosiderin deposits. The extensive multiplicity and hemorrhage encountered in this case have rarely been reported in patients with subependymoma.

  20. Dura mater graft-associated Creutzfeldt-Jakob disease with 30-year incubation period.

    PubMed

    Shijo, Masahiro; Honda, Hiroyuki; Koyama, Sachiko; Ishitsuka, Koji; Maeda, Koichiro; Kuroda, Junya; Tanii, Mitsugu; Kitazono, Takanari; Iwaki, Toru

    2017-06-01

    Over 60% of all patients with dura mater graft-associated Creutzfeldt-Jakob disease (dCJD) have been diagnosed in Japan. The incubation period has ranged from 1 to 30 years and the age at onset from 15 to 80 years. Here, we report a 77-year-old male Japanese autopsied dCJD case with the longest incubation period so far in Japan. He received a cadaveric dural graft at the right cranial convexity following a craniotomy for meningioma at the age of 46. At 30 years post-dural graft placement, disorientation was observed as an initial symptom of dCJD. He rapidly began to present with inconsistent speech, cognitive impairment and tremor of the left upper extremity. Occasional myoclonic jerks were predominantly observed on the left side. Brain MRI presented hyperintense signals on diffusion-weighted and T2-weighted images, at the right cerebral cortex. The most hyperintense lesion was located at the right parietal lobe, where the dura mater graft had been transplanted. Single-photon emission CT scan showed markedly decreased cerebral blood flow at the right parietal lobe. EEG revealed diffuse and slow activities with periodic sharp-wave complex discharges seen in the right parietal, temporal and occipital lobes. He died of pneumonia 9 months after onset. Brain pathology revealed non-plaque-type dCJD. Laterality of neuropathological changes, including spongiform change, neuronal loss, gliosis or PrP deposits, was not evident. Western blot analysis showed type 1 PrP CJD . Alzheimer-type pathology and PSP-like pathology were also observed. © 2016 Japanese Society of Neuropathology.

Top