Sample records for ct side information

  1. Longitudinal perceptions of the side effects of chemotherapy in patients with gynecological cancer.

    PubMed

    Hsu, Hui-Chun; Tsai, Su-Yu; Wu, Shang-Liang; Jeang, Shiow-Roug; Ho, Mei-Yao; Liou, Wen-Shiung; Chiang, An-Jen; Chang, Tsung-Hsien

    2017-11-01

    This study aimed to assess the incidence and difference of side effects among six courses of chemotherapy (C/T) in gynecological cancer patients. The study period was from Sep. 2010 to Dec. 2011 at the Kaohsiung Veterans General Hospital in Taiwan. The treating protocols, courses, and drugs of C/T in patient were considered according to the different malignant cancers and clinical conditions. The patient data of age, marriage status, education, religion, and experiences of C/T were collected. The patients' or their families' reported side effects of C/T were recorded daily from the beginning of C/T to the 10th day after C/T in each cycle and every course of C/T. Total 89 patients enrolled into the study received total 450 courses of C/T. The mean age was 54.52 ± 11.02. Ovarian cancer was the most common malignant disease (64.0%). The most often combination of drugs used was Taxol and carboplatin (40.9%). Patients complained peripheral numbness of limbs, with the highest incidence of 58.6%. The side effects with incidence about 50% were decreased fatigue (55.0%) and hair loss (49.9%). Other side effects with different levels of incidence were also noticed, such as lack of appetite, changes in taste, and muscle ache. The incidences of peripheral limb numbness and hair loss were increased with following courses of C/T. The high incidence of fatigue did not show variation between different courses of C/T. This study revealed the incidence of side effects and occurrence timing during C/T in patients with gynecological cancer. These data provide substantial information to patients and their families to understand the potential side effects of C/T courses, which might increase their compliance in receiving adjuvant C/T. Relieving the side effects in C/T would be important to improve their quality of daily life and treatment willingness.

  2. Benign Prostatic Hyperplasia: Cone-Beam CT in Conjunction with DSA for Identifying Prostatic Arterial Anatomy.

    PubMed

    Wang, Mao Qiang; Duan, Feng; Yuan, Kai; Zhang, Guo Dong; Yan, Jieyu; Wang, Yan

    2017-01-01

    Purpose To describe findings in prostatic arteries (PAs) at digital subtraction angiography (DSA) and cone-beam computed tomography (CT) that allow identification of benign prostatic hyperplasia and to determine the value added with the use of cone-beam CT. Materials and Methods This retrospective single-institution study was approved by the institutional review board, and the requirement for written informed consent was waived. From February 2009 to December 2014, a total of 148 patients (mean age ± standard deviation, 70.5 years ± 14.5) underwent DSA of the internal iliac arteries and cone-beam CT with a flat-detector angiographic system before they underwent prostate artery embolization. Both the DSA and cone-beam CT images were evaluated by two interventional radiologists to determine the number of independent PAs and their origins and anastomoses with adjacent arteries. The exact McNemar test was used to compare the detection rate of the PAs and the anastomoses with DSA and with cone-beam CT. Results The PA anatomy was evaluated successfully by means of cone-beam CT in conjunction with DSA in all patients. Of the 296 pelvic sides, 274 (92.6%) had only one PA. The most frequent PA origin was the common gluteal-pudendal trunk with the superior vesicular artery in 118 (37.1%), followed by the anterior division of the internal iliac artery in 99 (31.1%), and the internal pudendal artery in 77 (24.2%) pelvic sides. In 67 (22.6%) pelvic sides, anastomoses to adjacent arteries were documented. The numbers of PA origins and anastomoses, respectively, that could be identified were significantly higher with cone-beam CT (301 of 318 [94.7%] and 65 of 67 [97.0%]) than with DSA (237 [74.5%] and 39 [58.2%], P < .05). Cone-beam CT provided essential information that was not available with DSA in 90 of 148 (60.8%) patients. Conclusion Cone-beam CT is a useful adjunctive technique to DSA for identification of the PA anatomy and provides information to help treatment planning during prostatic arterial embolization. © RSNA, 2016.

  3. Model-based estimation with boundary side information or boundary regularization [cardiac emission CT].

    PubMed

    Chiao, P C; Rogers, W L; Fessler, J A; Clinthorne, N H; Hero, A O

    1994-01-01

    The authors have previously developed a model-based strategy for joint estimation of myocardial perfusion and boundaries using ECT (emission computed tomography). They have also reported difficulties with boundary estimation in low contrast and low count rate situations. Here they propose using boundary side information (obtainable from high resolution MRI and CT images) or boundary regularization to improve both perfusion and boundary estimation in these situations. To fuse boundary side information into the emission measurements, the authors formulate a joint log-likelihood function to include auxiliary boundary measurements as well as ECT projection measurements. In addition, they introduce registration parameters to align auxiliary boundary measurements with ECT measurements and jointly estimate these parameters with other parameters of interest from the composite measurements. In simulated PET O-15 water myocardial perfusion studies using a simplified model, the authors show that the joint estimation improves perfusion estimation performance and gives boundary alignment accuracy of <0.5 mm even at 0.2 million counts. They implement boundary regularization through formulating a penalized log-likelihood function. They also demonstrate in simulations that simultaneous regularization of the epicardial boundary and myocardial thickness gives comparable perfusion estimation accuracy with the use of boundary side information.

  4. Levator Muscle Enlargement in Thyroid Eye Disease-Related Upper Eyelid Retraction.

    PubMed

    Davies, Michael J; Dolman, Peter J

    To identify levator palpebrae superioris enlargement in thyroid eye disease (TED)-related upper eyelid retraction (ULR). Retrospective case-control. Subjects included 50 consecutive patients with unilateral thyroid eye disease-related ULR ≥ 2 mm and no previous eyelid surgery. The contralateral side was used as control. Clinical information was recorded from charts. CT scans were assessed by investigators blinded to the clinical data. A prediction of retracted side was made based on CT scan appearance and on basis of measured levator palpebrae superioris cross-sectional area at 2 defined points. Statistical analysis determined correlation between levator palpebrae superioris size and presence of ULR. The study was approved by the institutional ethics committee. Side with ULR predicted from CT scan review in over 85% of cases. Mean cross-sectional area of levator palpebrae superioris on retracted side was significantly larger than nonretracted side at 2 separate sites. Levator palpebrae superioris area was larger on retracted side compared with nonretracted side in over 85% of subjects. More than 30% of subjects had no enlargement of other extraocular muscles. Only 6% of patients had enlargement of the ipsilateral inferior rectus muscle. Levator palpebrae superioris enlargement from inflammation or scar is a factor in thyroid eye disease-related ULR. Upper eyelid retraction can be predicted from CT scan appearance in over 85% of cases. Ipsilateral inferior rectus enlargement is rare. Levator palpebrae superioris is the most commonly targeted muscle in thyroid eye disease.

  5. Assessment of Intrafraction Breathing Motion on Left Anterior Descending Artery Dose During Left-Sided Breast Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El-Sherif, Omar, E-mail: Omar.ElSherif@lhsc.on.ca; Department of Physics, London Regional Cancer Program, London, Ontario; Yu, Edward

    Purpose: To use 4-dimensional computed tomography (4D-CT) imaging to predict the level of uncertainty in cardiac dose estimates of the left anterior descending artery that arises due to breathing motion during radiation therapy for left-sided breast cancer. Methods and Materials: The fast helical CT (FH-CT) and 4D-CT of 30 left-sided breast cancer patients were retrospectively analyzed. Treatment plans were created on the FH-CT. The original treatment plan was then superimposed onto all 10 phases of the 4D-CT to quantify the dosimetric impact of respiratory motion through 4D dose accumulation (4D-dose). Dose-volume histograms for the heart, left ventricle (LV), and left anteriormore » descending (LAD) artery obtained from the FH-CT were compared with those obtained from the 4D-dose. Results: The 95% confidence interval of 4D-dose and FH-CT differences in mean dose estimates for the heart, LV, and LAD were ±0.5 Gy, ±1.0 Gy, and ±8.7 Gy, respectively. Conclusion: Fast helical CT is a good approximation for doses to the heart and LV; however, dose estimates for the LAD are susceptible to uncertainties that arise due to intrafraction breathing motion that cannot be ascertained without the additional information obtained from 4D-CT and dose accumulation. For future clinical studies, we suggest the use of 4D-CT–derived dose-volume histograms for estimating the dose to the LAD.« less

  6. Multiple supervised residual network for osteosarcoma segmentation in CT images.

    PubMed

    Zhang, Rui; Huang, Lin; Xia, Wei; Zhang, Bo; Qiu, Bensheng; Gao, Xin

    2018-01-01

    Automatic and accurate segmentation of osteosarcoma region in CT images can help doctor make a reasonable treatment plan, thus improving cure rate. In this paper, a multiple supervised residual network (MSRN) was proposed for osteosarcoma image segmentation. Three supervised side output modules were added to the residual network. The shallow side output module could extract image shape features, such as edge features and texture features. The deep side output module could extract semantic features. The side output module could compute the loss value between output probability map and ground truth and back-propagate the loss information. Then, the parameters of residual network could be modified by gradient descent method. This could guide the multi-scale feature learning of the network. The final segmentation results were obtained by fusing the results output by the three side output modules. A total of 1900 CT images from 15 osteosarcoma patients were used to train the network and a total of 405 CT images from another 8 osteosarcoma patients were used to test the network. Results indicated that MSRN enabled a dice similarity coefficient (DSC) of 89.22%, a sensitivity of 88.74% and a F1-measure of 0.9305, which were larger than those obtained by fully convolutional network (FCN) and U-net. Thus, MSRN for osteosarcoma segmentation could give more accurate results than FCN and U-Net. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Complementary therapies for cancer patients: assessing information use and needs.

    PubMed

    Verhoef, M J; Trojan, L; Armitage, G D; Carlson, L; Hilsden, R J

    2009-01-01

    Many cancer patients seek complementary therapies (CTs) for cancer management; however, relatively little is known about patients' CT information seeking behaviour. Therefore, we assessed: 1) cancer patients' use of the types and sources of CT information; 2) their information preferences; and 3) their understanding of the phrase "scientific evidence or proof that a therapy works." We collected data from 404 patients attending the Tom Baker Cancer Centre (TBCC) in Calgary and 303 patients calling the Cancer Information Service (CIS) helpline. In most cases, patients wanted information on the safety of CTs, how CTs work and their potential side effects. Physicians and conventional cancer centres were the most desired sources of CT information, but relatively few patients obtained information via these sources. Although patients were aware of the meaning of scientific evidence, they often used information based on non-scientific evidence, such as patient testimonials. The creation of a supportive care environment in conventional cancer treatment centres, by providing CT information, may help address cancer patients' concerns and alleviate some of the stress that may have been caused by the cancer diagnosis.

  8. [18F-Fluorocholine PET-CT for localization of parathyroid adenomas].

    PubMed

    Kluijfhout, Wouter P; Vriens, Menno R; Borel Rinkes, Inne H M; Valk, Gerlof D; de Klerk, John M H; de Keizer, Bart

    2015-01-01

    18F-fluorocholine PET-CT is a new imaging modality for the localization of pathological parathyroid glands in patients with primary hyperparathyroidism. The PET-CT is a combination scan that uses both the physiological information from the PET and the anatomical information from the CT. Uptake of the radio-isotope 18F-fluorocholine is increased in pathological parathyroid glands. 18F-fluorocholine PET-CT helps clinicians to localize the pathological parathyroid glands where conventional modalities fail to do so. This enables surgeons to carry out targeted minimal invasive surgery. It may also prevent the patient having to undergo a more extensive exploration, with its associated risks, and alleviate the necessity of taking medications with side effects. Although the literature on this subject is still scarce, preliminary results are promising. As any hospital with a PET-CT can perform the scan, we expect that its use in patients with hyperparathyroidism will increase over the next few years.

  9. Diagnostic accuracy of a volume-rendered computed tomography movie and other computed tomography-based imaging methods in assessment of renal vascular anatomy for laparoscopic donor nephrectomy.

    PubMed

    Yamamoto, Shingo; Tanooka, Masao; Ando, Kumiko; Yamano, Toshiko; Ishikura, Reiichi; Nojima, Michio; Hirota, Shozo; Shima, Hiroki

    2009-12-01

    To evaluate the diagnostic accuracy of computed tomography (CT)-based imaging methods for assessing renal vascular anatomy, imaging studies, including standard axial CT, three-dimensional volume-rendered CT (3DVR-CT), and a 3DVR-CT movie, were performed on 30 patients who underwent laparoscopic donor nephrectomy (10 right side, 20 left side) for predicting the location of the renal arteries and renal, adrenal, gonadal, and lumbar veins. These findings were compared with videos obtained during the operation. Two of 37 renal arteries observed intraoperatively were missed by standard axial CT and 3DVR-CT, whereas all arteries were identified by the 3DVR-CT movie. Two of 36 renal veins were missed by standard axial CT and 3DVR-CT, whereas 1 was missed by the 3DVR-CT movie. In 20 left renal hilar anatomical structures, 20 adrenal, 20 gonadal, and 22 lumbar veins were observed during the operation. Preoperatively, the standard axial CT, 3DVR-CT, and 3DVR-CT movie detected 11, 19, and 20 adrenal veins; 13, 14, and 19 gonadal veins; and 6, 11, and 15 lumbar veins, respectively. Overall, of 135 renal vascular structures, the standard axial CT, 3DVR-CT, and 3DVR-CT movie accurately detected 99 (73.3%), 113 (83.7%), and 126 (93.3%) vessels, respectively, which indicated that the 3DVR-CT movie demonstrated a significantly higher detection rate than other CT-based imaging methods (P < 0.05). The 3DVR-CT movie accurately provides essential information about the renal vascular anatomy before laparoscopic donor nephrectomy.

  10. Variations of the superficial middle cerebral vein: classification using three-dimensional CT angiography.

    PubMed

    Suzuki, Y; Matsumoto, K

    2000-05-01

    Classification of variations of the superficial middle cerebral vein (SMCV) remains ambiguous. We propose a new classification system based on embryologic development for preoperative examination. Three-dimensional CT angiography was used to evaluate 500 SMCVs (in 250 patients). The outflow vessels from the SMCV were classified into seven types on the basis of embryologic development. The 3D CT angiograms in axial stereoscopic and oblique views and multiple intensity projection images were evaluated by the same neurosurgeon on two occasions. Inconsistent interpretations were regarded as equivocal. Three-dimensional CT angiography clearly depicted the SMCV running along the lesser wing or the middle cranial fossa. However, the outflow vessel could not be confirmed as the sphenoparietal, cavernous, or emissary type in 39 (8%) of the sides. SMCVs running in the middle cranial fossa to join the transverse sinus or superior petrosal sinus were accurately identified. SMCVs were present in 456 sides: 62% entered the sphenoparietal sinus or the cavernous sinus and 12% joined the emissary vein. Nine vessels were the superior petrosal type, 10 the basal type, 12 the squamosal type, and 44 the undeveloped type. Three-dimensional CT angiography can depict the vessels and their anatomic relationship to the bone structure, allowing identification of the SMCV variant in individual patients. Preoperative planning for skull base surgery requires such information to reduce the invasiveness of the procedure. With the use of our classification system, 3D CT angiography can provide exact and practical information concerning the SMCV.

  11. CT of the ear in Pendred syndrome.

    PubMed

    Goldfeld, Moshe; Glaser, Benjamin; Nassir, Elias; Gomori, John Moshe; Hazani, Elitsur; Bishara, Nassir

    2005-05-01

    To prospectively determine the structural anomalies of the inner ear by using thin-section computed tomography (CT) in an extended family with Pendred syndrome. Ethics committee approved the study, and informed consent was obtained from every patient or from parents of patients under legal age. Twelve patients (three females and nine males aged 7-47 years) with Pendred syndrome (all from the same ethnic isolate and with the same mutation in the PDS gene) were evaluated for inner-ear malformation at thin-section CT. Both ears were evaluated. Presence or absence of interscalar septum between upper and middle turns of the cochlea was evaluated, and vestibule and vestibular aqueduct were examined for enlargement. Modiolus was determined to be present or absent (modiolar deficiency). CT scans were evaluated in consensus by two radiologists (M.G., J.M.G.). All patients had inner ear malformation on both sides. Modiolus was absent and vestibule was enlarged on both sides in all 12 patients. Interscalar septum was absent in 18 (75%) of 24 ears. In eight patients, interscalar septum was absent in both ears, whereas in two patients, it was absent on only one side. Aqueduct was enlarged in 20 (80%) of 24 ears. In nine patients, both ears had enlarged aqueducts, while in two patients, only one side was abnormal. Inner ear malformation is an invariable finding in Pendred syndrome. Modiolus deficiency and vestibular enlargement were the most consistent anomalies in this population with Pendred syndrome. (c) RSNA, 2005.

  12. Hybrid-fusion SPECT/CT systems in parathyroid adenoma: Technological improvements and added clinical diagnostic value.

    PubMed

    Wong, K K; Chondrogiannis, S; Bowles, H; Fuster, D; Sánchez, N; Rampin, L; Rubello, D

    Nuclear medicine traditionally employs planar and single photon emission computed tomography (SPECT) imaging techniques to depict the biodistribution of radiotracers for the diagnostic investigation of a range of disorders of endocrine gland function. The usefulness of combining functional information with anatomy derived from computed tomography (CT), magnetic resonance imaging (MRI), and high resolution ultrasound (US), has long been appreciated, either using visual side-by-side correlation, or software-based co-registration. The emergence of hybrid SPECT/CT camera technology now allows the simultaneous acquisition of combined multi-modality imaging, with seamless fusion of 3D volume datasets. Thus, it is not surprising that there is growing literature describing the many advantages that contemporary SPECT/CT technology brings to radionuclide investigation of endocrine disorders, showing potential advantages for the pre-operative locating of the parathyroid adenoma using a minimally invasive surgical approach, especially in the presence of ectopic glands and in multiglandular disease. In conclusion, hybrid SPECT/CT imaging has become an essential tool to ensure the most accurate diagnostic in the management of patients with hyperparathyroidism. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  13. Synthetic Hounsfield units from spectral CT data

    NASA Astrophysics Data System (ADS)

    Bornefalk, Hans

    2012-04-01

    Beam-hardening-free synthetic images with absolute CT numbers that radiologists are used to can be constructed from spectral CT data by forming ‘dichromatic’ images after basis decomposition. The CT numbers are accurate for all tissues and the method does not require additional reconstruction. This method prevents radiologists from having to relearn new rules-of-thumb regarding absolute CT numbers for various organs and conditions as conventional CT is replaced by spectral CT. Displaying the synthetic Hounsfield unit images side-by-side with images reconstructed for optimal detectability for a certain task can ease the transition from conventional to spectral CT.

  14. Cardiopulmonary manifestations of isolated pulmonary valve infective endocarditis demonstrated with cardiac CT.

    PubMed

    Passen, Edward; Feng, Zekun

    2015-01-01

    Right-sided infective endocarditis involving the pulmonary valve is rare. This pictorial essay discusses the use and findings of cardiac CT combined with delayed chest CT and noncontrast chest CT of pulmonary valve endocarditis. Cardiac CT is able to show the full spectrum of right-sided endocarditis cardiopulmonary features including manifestations that cannot be demonstrated by echocardiography. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  15. Using three-dimensional-computerized tomography as a diagnostic tool for temporo-mandibular joint ankylosis: a case report.

    PubMed

    Kao, S Y; Chou, J; Lo, J; Yang, J; Chou, A P; Joe, C J; Chang, R C

    1999-04-01

    Roentgenographic examination has long been a useful diagnostic tool for temporo-mandibular joint (TMJ) disease. The methods include TMJ tomography, panoramic radiography and computerized tomography (CT) scan with or without injection of contrast media. Recently, three-dimensional CT (3D-CT), reconstructed from the two-dimensional image of a CT scan to simulate the soft tissue or bony structure of the real target, was proposed. In this report, a case of TMJ ankylosis due to traumatic injury is presented. 3D-CT was employed as one of the presurgical roentgenographic diagnostic tools. The conventional radiographic examination including panoramic radiography and tomography showed lesions in both sides of the mandible. CT scanning further suggested that the right-sided lesion was more severe than that on the left. With 3D-CT image reconstruction the size and extent of the lesions were clearly observable. The decision was made to proceed with an initial surgical approach on the right side. With condylectomy and condylar replacement using an autogenous costochondral graft on the right side, the range of mouth opening improved significantly. In this case report, 3D-CT demonstrates its advantages as a tool for the correct and precise diagnosis of TMJ ankylosis.

  16. Magnetic resonance imaging versus computed tomography to plan hemilaminectomies in chondrodystrophic dogs with intervertebral disc extrusion.

    PubMed

    Noyes, Julie A; Thomovsky, Stephanie A; Chen, Annie V; Owen, Tina J; Fransson, Boel A; Carbonneau, Kira J; Matthew, Susan M

    2017-10-01

    To determine the influence of preoperative computed tomography (CT) versus magnetic resonance (MR) on hemilaminectomies planned to treat thoracolumbar (TL) intervertebral disc (IVD) extrusions in chondrodystrophic dogs. Prospective clinical study. Forty chondrodystrophic dogs with TL IVD extrusion and preoperative CT and MR studies. MR and CT images were randomized and reviewed by 4 observers masked to the dog's identity and corresponding imaging studies. Observers planned the location along the spine, side, and extent (number of articular facets to be removed) based on individual reviews of CT and MR studies. Intra-observer agreement was determined between overall surgical plan, location, side, and size of the hemilaminectomy planned on CT versus MR of the same dog. Similar surgical plans were developed based on MR versus CT in 43.5%-66.6% of dogs, depending on the observer. Intra-observer agreement in location, side, and size of the planned hemilaminectomy based on CT versus MR ranged between 48.7%-66.6%, 87%-92%, and 51.2%-71.7% of dogs, respectively. Observers tended to plan larger laminectomy defects based on MR versus CT of the same dog. Findings from this study indicated considerable differences in hemilaminectomies planned on preoperative MR versus CT imaging. Surgical location and size varied the most; the side of planned hemilaminectomies was most consistent between imaging modalities. © 2017 The American College of Veterinary Surgeons.

  17. [Injection Pressure Evaluation of the New Venous Catheter with Side Holes for Contrast-enhanced CT/MRI].

    PubMed

    Fukuda, Junya; Arai, Keisuke; Miyazawa, Hitomi; Kobayashi, Kyouko; Nakamura, Junpei; Suto, Takayuki; Tsushima, Yoshito

    2018-01-01

    The simulation study was conducted for the new venous catheter with side holes of contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) to evaluate the infusion pressure on four contrast media and several injection speeds. All infusion pressure of the new venous catheter with side holes were less than 15 kg/cm 2 as limitation of extension tube and also reduced the infusion pressure by 15% at the maximum compared to the catheter with single hole. The results suggest that the new venous catheter with side holes can reduce the infusion pressure by power injection of contrast-enhanced CT and MRI.

  18. Subvalvular pannus and thrombosis in a mitral valve prosthesis.

    PubMed

    Kim, Gun Ha; Yang, Dong Hyun; Kang, Joon-Won; Kim, Dae-Hee; Jung, Sung-Ho; Lim, Tae-Hwan

    2016-01-01

    A 69-year-old female underwent cardiac CT to evaluate prosthetic valve (PHV) dysfunction detected on echocardiography. A CT coronal and en face views of the mitral annular plane showed a low-density, mass-like lesion on the left atrial side of the PHV and a high-density, plate-like lesion on the left ventricular side of PHV. A repeat of the mitral valve replacement was performed, and preoperative CT findings of both the thrombus on the left atrial side and pannus formation on the LV side were confirmed in the operative findings. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  19. Uncertainties in estimating heart doses from 2D-tangential breast cancer radiotherapy.

    PubMed

    Lorenzen, Ebbe L; Brink, Carsten; Taylor, Carolyn W; Darby, Sarah C; Ewertz, Marianne

    2016-04-01

    We evaluated the accuracy of three methods of estimating radiation dose to the heart from two-dimensional tangential radiotherapy for breast cancer, as used in Denmark during 1982-2002. Three tangential radiotherapy regimens were reconstructed using CT-based planning scans for 40 patients with left-sided and 10 with right-sided breast cancer. Setup errors and organ motion were simulated using estimated uncertainties. For left-sided patients, mean heart dose was related to maximum heart distance in the medial field. For left-sided breast cancer, mean heart dose estimated from individual CT-scans varied from <1Gy to >8Gy, and maximum dose from 5 to 50Gy for all three regimens, so that estimates based only on regimen had substantial uncertainty. When maximum heart distance was taken into account, the uncertainty was reduced and was comparable to the uncertainty of estimates based on individual CT-scans. For right-sided breast cancer patients, mean heart dose based on individual CT-scans was always <1Gy and maximum dose always <5Gy for all three regimens. The use of stored individual simulator films provides a method for estimating heart doses in left-tangential radiotherapy for breast cancer that is almost as accurate as estimates based on individual CT-scans. Copyright © 2016. Published by Elsevier Ireland Ltd.

  20. Changes in entrance surface dose in relation to the location of shielding material in chest computed tomography

    NASA Astrophysics Data System (ADS)

    Kang, Y. M.; Cho, J. H.; Kim, S. C.

    2015-07-01

    This study examined the effects of entrance surface dose (ESD) on the abdomen and pelvis of the patient when undergoing chest computed tomography (CT) procedure, and evaluated the effects of ESD reduction depending on the location of radiation shield. For CT scanner, the 64-slice multi-detector computed tomography was used. The alderson radiation therapy phantom and optically stimulated luminescence dosimeter (OSLD), which enabled measurement from low to high dose, were also used. For measurement of radiation dose, the slice number from 9 to 21 of the phantom was set as the test range, which included apex up to both costophrenic angles. A total of 10 OSLD nanoDots were attached for measurement of the front and rear ESD. Cyclic tests were performed using the low-dose chest CT and high-resolution CT (HRCT) protocol on the following set-ups: without shielding; shielding only on the front side; shielding only on the rear side; and shielding for both front and rear sides. According to the test results, ESD for both front and rear sides was higher in HRCT than low-dose CT when radiation shielding was not used. It was also determined that, compared to the set-up that did not use the radiation shield, locating the radiation shield on the front side was effective in reducing front ESD, while locating the radiation shield on the rear side reduced rear ESD level. Shielding both the front and rear sides resulted in ESD reduction. In conclusion, it was confirmed that shielding the front and rear sides was the most effective method to reduce the ESD effect caused by scatter ray during radiography.

  1. Attenuation-emission alignment in cardiac PET∕CT based on consistency conditions

    PubMed Central

    Alessio, Adam M.; Kinahan, Paul E.; Champley, Kyle M.; Caldwell, James H.

    2010-01-01

    Purpose: In cardiac PET and PET∕CT imaging, misaligned transmission and emission images are a common problem due to respiratory and cardiac motion. This misalignment leads to erroneous attenuation correction and can cause errors in perfusion mapping and quantification. This study develops and tests a method for automated alignment of attenuation and emission data. Methods: The CT-based attenuation map is iteratively transformed until the attenuation corrected emission data minimize an objective function based on the Radon consistency conditions. The alignment process is derived from previous work by Welch et al. [“Attenuation correction in PET using consistency information,” IEEE Trans. Nucl. Sci. 45, 3134–3141 (1998)] for stand-alone PET imaging. The process was evaluated with the simulated data and measured patient data from multiple cardiac ammonia PET∕CT exams. The alignment procedure was applied to simulations of five different noise levels with three different initial attenuation maps. For the measured patient data, the alignment procedure was applied to eight attenuation-emission combinations with initially acceptable alignment and eight combinations with unacceptable alignment. The initially acceptable alignment studies were forced out of alignment a known amount and quantitatively evaluated for alignment and perfusion accuracy. The initially unacceptable studies were compared to the proposed aligned images in a blinded side-by-side review. Results: The proposed automatic alignment procedure reduced errors in the simulated data and iteratively approaches global minimum solutions with the patient data. In simulations, the alignment procedure reduced the root mean square error to less than 5 mm and reduces the axial translation error to less than 1 mm. In patient studies, the procedure reduced the translation error by >50% and resolved perfusion artifacts after a known misalignment for the eight initially acceptable patient combinations. The side-by-side review of the proposed aligned attenuation-emission maps and initially misaligned attenuation-emission maps revealed that reviewers preferred the proposed aligned maps in all cases, except one inconclusive case. Conclusions: The proposed alignment procedure offers an automatic method to reduce attenuation correction artifacts in cardiac PET∕CT and provides a viable supplement to subjective manual realignment tools. PMID:20384256

  2. True left-sided gallbladder with variations of bile duct and cholecystic vein.

    PubMed

    Ishii, Hiromichi; Noguchi, Akinori; Onishi, Mie; Takao, Koji; Maruyama, Takahiro; Taiyoh, Hiroaki; Araki, Yasunobu; Shimizu, Takeshi; Izumi, Hiroyuki; Tani, Naoki; Yamaguchi, Masahide; Yamane, Tetsuro

    2015-06-07

    A left-sided gallbladder without a right-sided round ligament, which is called a true left-sided gallbladder, is extremely rare. A 71-year-old woman was referred to our hospital due to a gallbladder polyp. Computed tomography (CT) revealed not only a gallbladder polyp but also the gallbladder located to the left of the round ligament connected to the left umbilical portion. CT portography revealed that the main portal vein diverged into the right posterior portal vein and the common trunk of the left portal vein and right anterior portal vein. CT cholangiography revealed that the infraportal bile duct of segment 2 joined the common bile duct. Laparoscopic cholecystectomy was performed for a gallbladder polyp, and the intraoperative finding showed that the cholecystic veins joined the round ligament. A true left-sided gallbladder is closely associated with several anomalies; therefore, surgeons encountering a true left-sided gallbladder should be aware of the potential for these anomalies.

  3. True left-sided gallbladder with variations of bile duct and cholecystic vein

    PubMed Central

    Ishii, Hiromichi; Noguchi, Akinori; Onishi, Mie; Takao, Koji; Maruyama, Takahiro; Taiyoh, Hiroaki; Araki, Yasunobu; Shimizu, Takeshi; Izumi, Hiroyuki; Tani, Naoki; Yamaguchi, Masahide; Yamane, Tetsuro

    2015-01-01

    A left-sided gallbladder without a right-sided round ligament, which is called a true left-sided gallbladder, is extremely rare. A 71-year-old woman was referred to our hospital due to a gallbladder polyp. Computed tomography (CT) revealed not only a gallbladder polyp but also the gallbladder located to the left of the round ligament connected to the left umbilical portion. CT portography revealed that the main portal vein diverged into the right posterior portal vein and the common trunk of the left portal vein and right anterior portal vein. CT cholangiography revealed that the infraportal bile duct of segment 2 joined the common bile duct. Laparoscopic cholecystectomy was performed for a gallbladder polyp, and the intraoperative finding showed that the cholecystic veins joined the round ligament. A true left-sided gallbladder is closely associated with several anomalies; therefore, surgeons encountering a true left-sided gallbladder should be aware of the potential for these anomalies. PMID:26074714

  4. The Primary Care Electronic Library: RSS feeds using SNOMED-CT indexing for dynamic content delivery.

    PubMed

    Robinson, Judas; de Lusignan, Simon; Kostkova, Patty; Madge, Bruce; Marsh, A; Biniaris, C

    2006-01-01

    Rich Site Summary (RSS) feeds are a method for disseminating and syndicating the contents of a website using extensible mark-up language (XML). The Primary Care Electronic Library (PCEL) distributes recent additions to the site in the form of an RSS feed. When new resources are added to PCEL, they are manually assigned medical subject headings (MeSH terms), which are then automatically mapped to SNOMED-CT terms using the Unified Medical Language System (UMLS) Metathesaurus. The library is thus searchable using MeSH or SNOMED-CT. Our syndicate partner wished to have remote access to PCEL coronary heart disease (CHD) information resources based on SNOMED-CT search terms. To pilot the supply of relevant information resources in response to clinically coded requests, using RSS syndication for transmission between web servers. Our syndicate partner provided a list of CHD SNOMED-CT terms to its end-users, a list which was coded according to UMLS specifications. When the end-user requested relevant information resources, this request was relayed from our syndicate partner's web server to the PCEL web server. The relevant resources were retrieved from the PCEL MySQL database. This database is accessed using a server side scripting language (PHP), which enables the production of dynamic RSS feeds on the basis of Source Asserted Identifiers (CODEs) contained in UMLS. Retrieving resources using SNOMED-CT terms using syndication can be used to build a functioning application. The process from request to display of syndicated resources took less than one second. The results of the pilot illustrate that it is possible to exchange data between servers using RSS syndication. This method could be utilised dynamically to supply digital library resources to a clinical system with SNOMED-CT data used as the standard of reference.

  5. Identification of Pulmonary Hypertension Caused by Left-Sided Heart Disease (World Health Organization Group 2) Based on Cardiac Chamber Volumes Derived From Chest CT Imaging.

    PubMed

    Aviram, Galit; Rozenbaum, Zach; Ziv-Baran, Tomer; Berliner, Shlomo; Topilsky, Yan; Fleischmann, Dominik; Sung, Yon K; Zamanian, Roham T; Guo, Haiwei Henry

    2017-10-01

    Evaluations of patients with pulmonary hypertension (PH) commonly include chest CT imaging. We hypothesized that cardiac chamber volumes calculated from the same CT scans can yield additional information to distinguish PH related to left-sided heart disease (World Health Organization group 2) from other PH subtypes. Patients who had PH confirmed by right heart catheterization and contrast-enhanced chest CT studies were enrolled in this retrospective multicenter study. Cardiac chamber volumes were calculated using automated segmentation software and compared between group 2 and non-group 2 patients with PH. This study included 114 patients with PH, 27 (24%) of whom were classified as group 2 based on their pulmonary capillary wedge pressure. Patients with group 2 PH exhibited significantly larger median left atrial (LA) volumes (118 mL vs 63 mL; P < .001), larger median left ventricular (LV) volumes (90 mL vs 76 mL; P = .02), and smaller median right ventricular (RV) volumes (173 mL vs 210 mL; P = .005) than did non-group 2 patients. On multivariate analysis adjusted for age, sex, and mean pulmonary arterial pressure, group 2 PH was significantly associated with larger median LA and LV volumes (P < .001 and P = .008, respectively) and decreased volume ratios of RA/LA, RV/LV, and RV/LA (P = .001, P = .004, and P < .001, respectively). Enlarged LA volumes demonstrated a high discriminatory ability for group 2 PH (area under the curve, 0.92; 95% CI, 0.870-0.968). Volumetric analysis of the cardiac chambers from nongated chest CT scans, particularly with findings of an enlarged left atrium, exhibited high discriminatory ability for identifying patients with PH due to left-sided heart disease. Copyright © 2017. Published by Elsevier Inc.

  6. Chlamydia trachomatis Infection and Anti-Hsp60 Immunity: The Two Sides of the Coin

    PubMed Central

    Cappello, Francesco; Conway de Macario, Everly; Di Felice, Valentina; Zummo, Giovanni; Macario, Alberto J. L.

    2009-01-01

    Chlamydia trachomatis (CT) infection is one of the most common causes of reproductive tract diseases and infertility. CT-Hsp60 is synthesized during infection and is released in the bloodstream. As a consequence, immune cells will produce anti-CT-Hsp60 antibodies. Hsp60, a ubiquitous and evolutionarily conserved chaperonin, is normally sequestered inside the cell, particularly into mitochondria. However, upon cell stress, as well as during carcinogenesis, the chaperonin becomes exposed on the cell surface (sf-Hsp60) and/or is secreted from cells into the extracellular space and circulation. Reports in the literature on circulating Hsp and anti-Hsp antibodies are in many cases short on details about Hsp60 concentrations, and about the specificity spectra of the antibodies, their titers, and their true, direct, pathogenetic effects. Thus, more studies are still needed to obtain a definitive picture on these matters. Nevertheless, the information already available indicates that the concurrence of persistent CT infection and appearance of sf-Hsp60 can promote an autoimmune aggression towards stressed cells and the development of diseases such as autoimmune arthritis, multiple sclerosis, atherosclerosis, vasculitis, diabetes, and thyroiditis, among others. At the same time, immunocomplexes composed of anti-CT-Hsp60 antibodies and circulating Hsp60 (both CT and human) may form deposits in several anatomical locations, e.g., at the glomerular basal membrane. The opposite side of the coin is that pre-tumor and tumor cells with sf-Hsp60 can be destroyed with participation of the anti-Hsp60 antibody, thus stopping cancer progression before it is even noticed by the patient or physician. PMID:19714222

  7. Predictors and Diagnostic Significance of the Adenosine Related Side Effects on Myocardial Perfusion SPECT/CT Imaging

    PubMed Central

    Yıldırım Poyraz, Nilüfer; Özdemir, Elif; Poyraz, Barış Mustafa; Kandemir, Zuhal; Keskin, Mutlay; Türkölmez, Şeyda

    2014-01-01

    Objective: The aim of this study was to investigate the relationship between patient characteristics and adenosine-related side-effects during stress myocard perfusion imaging (MPI). The effect of presence of adenosine-related side-effects on the diagnostic value of MPI with integrated SPECT/CT system for coronary artery disease (CAD), was also assessed in this study. Methods: Total of 281 patients (109 M, 172 F; mean age:62.6±10) who underwent standard adenosine stress protocol for MPI, were included in this study. All symptoms during adenosine infusion were scored according to the severity and duration. For the estimation of diagnostic value of adenosine MPI with integrated SPECT/CT system, coronary angiography (CAG) or clinical follow-up were used as gold standard. Results: Total of 173 patients (61.6%) experienced adenosine-related side-effects (group 1); flushing, dyspnea, and chest pain were the most common. Other 108 patients completed pharmacologic stress (PS) test without any side-effects (group 2). Test tolerability were similar in the patients with cardiovascular or airway disease to others, however dyspnea were observed significantly more common in patients with mild airway disease. Body mass index (BMI) ≥30 kg/m2 and age ≤45 years were independent predictors of side-effects. The diagnostic value of MPI was similar in both groups. Sensitivity of adenosine MPI SPECT/CT was calculated to be 86%, specificity was 94% and diagnostic accuracy was 92% for diagnosis of CAD. Conclusion: Adenosine MPI is a feasible and well tolerated method in patients who are not suitable for exercise stress test as well as patients with cardiopulmonary disease. However age ≤45 years and BMI ≥30 kg/m2 are the positive predictors of adenosine-related side-effects, the diagnostic value of adenosine MPI SPECT/CT is not affected by the presence of adenosine related side-effects. PMID:25541932

  8. [CT measurement and clinical application of double-row suture anchor reconstruction for the treatment of Tossy type III acromioclavicular joint dislocation].

    PubMed

    Zhang, Chuan-Kai; Liu, Chen; Han, Bing; Feng, Hui; Chen, Qi-Zhong; Sunx, Sun Yi-Yan

    2017-04-25

    To study feasibility and reliability of reconstruction of the acromioclavicular ligament with double-row suture anchor for the treatment of acromioclavicular joint dislocation through coracoid coronal CT measurement, and to provide a new operation method for treating acromioclavicular joint dislocation. Total 60 healthy people received CT examination of shoulder joint, including 30 males and 30 females, ranging in age from 18 to 50 years old. The coronal width, thickness and 20 degree camber angle in the medial part of the toot of coronal were measured using CT scan. The results were applied to clinical treatment for 12 patients with acromioclavicular joint dislocation of Tossy III type. The width in the medial part of the root of the coracoid was(17.65±1.82) mm(left side) and (17.67±1.80) mm(right side) in males; (16.55±1.78) mm(left side) and (16.52±1.74) mm (right side) in females. The vertical thickness of the roots of the coracoid: (13.11±2.11) mm(left side) and (13.16±2.09) mm(right side) in males;(12.79±2.21) mm(left side) and (12.76±2.19) mm (right side) in females. The thickness of 20 degrees camber angle of the coracoid roots: (16.32±1.74) mm (left side) and (16.30±1.69) mm(right side) in males; (15.68±1.44) mm(left side) and (15.67±1.43) mm(right side) in females. Total 12 patients were treated with anchor nail with extraversion 20 degrees. The postoperative X-ray films showed bone anchors were located in the coracoid process, no bone splitting. Double-row suture anchor of 5 mm diameter nails can be placed into coracoid with extraversion 20 degrees, which is safety.

  9. KSC-04PD-2140

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. A worker watches as the giant-sized gear (left side) and sprocket (right side) is moved. It will be installed on a Crawler-Tranporter (CT). The drive sprocket turns the belt on the CT. The sprocket is mated to the gear that attaches to the drive motor. The CT travels on eight tracked tread belts, each containing 57 tread belt shoes, for a combined weight of 957,600 pounds. The CT carries the Space Shuttle atop its Mobile Launcher Platform, adding another 12 million pounds, from the Vehicle Assembly Building to the launch pad. NASA and United Space Alliance (USA) CT system engineers and USA technicians are repairing the sprockets and rollers on each belt before new shoes are installed. Replacement of the sprockets, gears and shoes is part of the most extensive maintenance work performed on the CT in its history.

  10. Progressive skeletal benefits of physical activity when young as assessed at the midshaft humerus in male baseball players.

    PubMed

    Warden, S J; Weatherholt, A M; Gudeman, A S; Mitchell, D C; Thompson, W R; Fuchs, R K

    2017-07-01

    Physical activity benefits the skeleton, but there is contrasting evidence regarding whether benefits differ at different stages of growth. The current study demonstrates that physical activity should be encouraged at the earliest age possible and be continued into early adulthood to gain most skeletal benefits. The current study explored physical activity-induced bone adaptation at different stages of somatic maturity by comparing side-to-side differences in midshaft humerus properties between male throwing athletes and controls. Throwers present an internally controlled model, while inclusion of control subjects removes normal arm dominance influences. Throwing athletes (n = 90) and controls (n = 51) were categorized into maturity groups (pre, peri, post-early, post-mid, and post-late) based on estimated years from peak height velocity (<-2, -2 to 2, 2 to 4, 4 to 10, and >10 years). Side-to-side percent differences in midshaft humerus cortical volumetric bone mineral density (Ct.vBMD) and bone mineral content (Ct.BMC); total (Tt.Ar), medullary (Me.Ar), and cortical (Ct.Ar) areas; average cortical thickness (Ct.Th); and polar Strength Strain Index (SSI P ) were assessed. Significant interactions between physical activity and maturity on side-to-side differences in Ct.BMC, Tt.Ar, Ct.Ar, Me.Ar, Ct.Th, and SSI P resulted from the following: (1) greater throwing-to-nonthrowing arm differences than dominant-to-nondominant arm differences in controls (all p < 0.05) and (2) throwing-to-nonthrowing arm differences in throwers being progressively greater across maturity groups (all p < 0.05). Regional analyses revealed greatest adaptation in medial and lateral sectors, particularly in the three post-maturity groups. Years throwing predicted 59% of the variance of the variance in throwing-to-nonthrowing arm difference in SSI P (p < 0.001). These data suggest that physical activity has skeletal benefits beginning prior to and continuing beyond somatic maturation and that a longer duration of exposure to physical activity has cumulative skeletal benefits. Thus, physical activity should be encouraged at the earliest age possible and be continued into early adulthood to optimize skeletal benefits.

  11. Sequential versus concomitant therapy for eradication of Helicobacter Pylori in patients with perforated duodenal ulcer: A randomized trial.

    PubMed

    Das, Roby; Sureshkumar, Sathasivam; Sreenath, Gubbi S; Kate, Vikram

    2016-01-01

    Comparison of Helicobacter pylori eradication rates, side effects, compliance, cost, and ulcer recurrence of sequential therapy (ST) with that of concomitant therapy (CT) in patients with perforated duodenal ulcer following simple omental patch closure. Sixty-eight patients with perforated duodenal ulcer treated with simple closure and found to be H. pylori positive on three months follow-up were randomized to receive either ST or CT for H. pylori eradication. Urease test and Giemsa stain were used to assess for H. pylori eradication status. Follow-up endoscopies were done after 3 months, 6 months, and 1 year to evaluate the ulcer recurrence. H. pylori eradication rates were similar in ST and CT groups on intention-to-treat (ITT) analysis (71.43% vs 81.80%,P = 0.40). Similar eradication rates were also found in per-protocol (PP) analysis (86.20% vs 90%,P = 0.71). Ulcer recurrence rate in ST groups and CT groups at 3 months (17.14% vs 6.06%,P = 0.26), 6 months (22.86% vs 9.09%,P = 0.19), and at 1 year (25.71% vs 15.15%,P = 0.37) of follow-up was also similar by ITT analysis. Compliance and side effects to therapies were comparable between the groups. The most common side effects were diarrhoea and metallic taste in ST and CT groups, respectively. A complete course of ST costs Indian Rupees (INR) 570.00, whereas CT costs INR 1080.00. H. pylori eradication rates, side effects, compliance, cost, and ulcer recurrences were similar between the two groups. The ST was more economical compared with CT.

  12. Right heart on multidetector CT

    PubMed Central

    Gopalan, D

    2011-01-01

    Right ventricular function plays an integral role in the pathogenesis and outcome of many cardiovascular diseases. Imaging the right ventricle has long been a challenge because of its complex geometry. In recent years there has been a tremendous expansion in multidetector row CT (MDCT) and its cardiac applications. By judicious modification of contrast medium protocol, it is possible to achieve good opacification of the right-sided cardiac chambers, thereby paving the way for exploring the overshadowed right heart. This article will describe the key features of right heart anatomy, review MDCT acquisition techniques, elaborate the various morphological and functional information that can be obtained, and illustrate some important clinical conditions associated with an abnormal right heart. PMID:22723537

  13. KSC-04PD-2142

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. Workers maneuver the giant-sized sprocket (left side) and gear (right side) for installation on the Crawler-Transporter behind it. The drive sprocket turns the belt on the CT. The sprocket is mated to the gear that attaches to the drive motor. The CT travels on eight tracked tread belts, each containing 57 tread belt shoes, for a combined weight of 957,600 pounds. The CT carries the Space Shuttle atop its Mobile Launcher Platform, adding another 12 million pounds, from the Vehicle Assembly Building to the launch pad. NASA and United Space Alliance (USA) CT system engineers and USA technicians are repairing the sprockets and rollers on each belt before new shoes are installed. Replacement of the sprockets, gears and shoes is part of the most extensive maintenance work performed on the CT in its history.

  14. KSC-04PD-2155

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. Workers get ready to install the giant-sized sprocket (left side) and gear (right side) on the Crawler-Transporter at left. The drive sprocket turns the belt on the CT. The sprocket is mated to the gear that attaches to the drive motor. The CT travels on eight tracked tread belts, each containing 57 tread belt shoes, for a combined weight of 957,600 pounds. The CT carries the Space Shuttle atop its Mobile Launcher Platform, adding another 12 million pounds, from the Vehicle Assembly Building to the launch pad. NASA and United Space Alliance (USA) CT system engineers and USA technicians are repairing the sprockets and rollers on each belt before new shoes are installed. Replacement of the sprockets, gears and shoes is part of the most extensive maintenance work performed on the CT in its history.

  15. KSC-04PD-2143

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. Workers get ready to install the giant-sized sprocket (left side) and gear (right side) on the Crawler-Transporter behind it.The drive sprocket turns the belt on the CT. The sprocket is mated to the gear that attaches to the drive motor. The CT travels on eight tracked tread belts, each containing 57 tread belt shoes, for a combined weight of 957,600 pounds. The CT carries the Space Shuttle atop its Mobile Launcher Platform, adding another 12 million pounds, from the Vehicle Assembly Building to the launch pad. NASA and United Space Alliance (USA) CT system engineers and USA technicians are repairing the sprockets and rollers on each belt before new shoes are installed. Replacement of the sprockets, gears and shoes is part of the most extensive maintenance work performed on the CT in its history.

  16. Perceptions and attitudes toward clinical trials in adolescent and young adults with cancer: a systematic review.

    PubMed

    Forcina, Victoria; Vakeesan, Branavan; Paulo, Chelsea; Mitchell, Laura; Bell, Jennifer Ah; Tam, Seline; Wang, Kate; Gupta, Abha A; Lewin, Jeremy

    2018-01-01

    Although cancer clinical trials (CT) offer opportunities for novel treatments that may lead to improved outcomes, adolescents and young adults (AYA) are less likely to participate in these trials as compared to younger children and older adults. We aimed to identify the perceptions and attitudes toward CT in AYA that influence trial participation. A systematic review of cancer literature was conducted that assessed perceptions and attitudes toward CT enrollment limited to AYA patients (defined as age 15-39). We estimated the frequency of identified themes by pooling identified studies. In total, six original research articles were identified that specifically addressed perceptions or attitudes that influenced CT participation in AYA patients. Three studies were conducted at pediatric centers - one at an AYA unit, one at an adult cancer hospital, and one was registry based. Major themes identified for CT acceptability included: hope for positive clinical affect, altruism, and having autonomy. Potential deterrents included: prolonged hospitalization, worry of side effects, and discomfort with experimentation. Limited information is available with regard to the perceptions and attitudes toward CT acceptability among AYA patients, especially those treated at adult cancer centers, which prevents generalization of data and themes. Future research assessing strategies for understanding and supporting CT decision-making processes among AYA represents a key focus for future funding to improve CT enrollment.

  17. 30. ELEVATION EAST FACE BLDG. 27. Fafnir Bearing Plant, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. ELEVATION EAST FACE BLDG. 27. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  18. 27. FIFTH FLOOR BLDG. 29 LOOKING NORTH. Fafnir Bearing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. FIFTH FLOOR BLDG. 29 LOOKING NORTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  19. 13. FIRST FLOOR BLDG. 28 LOOKING EAST. Fafnir Bearing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. FIRST FLOOR BLDG. 28 LOOKING EAST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  20. 26. SECOND FLOOR BLDG. 29 LOOKING NORTH. Fafnir Bearing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. SECOND FLOOR BLDG. 29 LOOKING NORTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  1. Artefacts of PET/CT images

    PubMed Central

    Pettinato, C; Nanni, C; Farsad, M; Castellucci, P; Sarnelli, A; Civollani, S; Franchi, R; Fanti, S; Marengo, M; Bergamini, C

    2006-01-01

    Positron emission tomography (PET) is a non-invasive imaging modality, which is clinically widely used both for diagnosis and accessing therapy response in oncology, cardiology and neurology. Fusing PET and CT images in a single dataset would be useful for physicians who could read the functional and the anatomical aspects of a disease in a single shot. The use of fusion software has been replaced in the last few years by integrated PET/CT systems, which combine a PET and a CT scanner in the same gantry. CT images have the double function to correct PET images for attenuation and can fuse with PET for a better visualization and localization of lesions. The use of CT for attenuation correction yields several advantages in terms of accuracy and patient comfort, but can also introduce several artefacts on PET-corrected images. PET/CT image artefacts are due primarily to metallic implants, respiratory motion, use of contrast media and image truncation. This paper reviews different types artefacts and their correction methods. PET/CT improves image quality and image accuracy. However, to avoid possible pitfalls the simultaneous display of both Computed Tomography Attenuation Corrected (CTAC) and non corrected PET images, side by side with CT images is strongly recommended. PMID:21614340

  2. 8. ELEVATION EAST FACE BLDG. 28A. Fafnir Bearing Plant, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. ELEVATION EAST FACE BLDG. 28A. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  3. 29. FIRST FLOOR BLDG. 45, "TRANE CENTRAVAC" LOOKING EAST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. FIRST FLOOR BLDG. 45, "TRANE CENTRAVAC" LOOKING EAST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  4. 9. FIRST FLOOR BLDG. 28B LOOKING WEST. Fafnir Bearing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. FIRST FLOOR BLDG. 28B LOOKING WEST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  5. 14. FIRST FLOOR BLDG. 28: DETAIL OCTAGONAL COLUMN. Fafnir ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. FIRST FLOOR BLDG. 28: DETAIL OCTAGONAL COLUMN. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  6. 25. SIXTH FLOOR BLDG. 28B LOOKING EAST. Fafnir Bearing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. SIXTH FLOOR BLDG. 28B LOOKING EAST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  7. 15. FIRST FLOOR BLDG. 28A LOOKING EAST. Fafnir Bearing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. FIRST FLOOR BLDG. 28A LOOKING EAST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  8. 5. OVERVIEW LOOKING WEST: taken from BLDG. 27. Fafnir ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. OVERVIEW LOOKING WEST: taken from BLDG. 27. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  9. 43. VIEW SMOKE STACK FOR BLDG. 4 LOOKING NORTHWEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. VIEW SMOKE STACK FOR BLDG. 4 LOOKING NORTHWEST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  10. 81. SOUTH FACE BLDG. 19, DETAIL OF SIGNAGE. Fafnir ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    81. SOUTH FACE BLDG. 19, DETAIL OF SIGNAGE. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  11. 33. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" LOOKING NORTH. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" LOOKING NORTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  12. 87. SIXTH FLOOR BLDG. 19 "CLEAN ROOM" LOOKING WEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    87. SIXTH FLOOR BLDG. 19 "CLEAN ROOM" LOOKING WEST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  13. 3. OVERVIEW LOOKING EAST: taken from north end BLDG. 1. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. OVERVIEW LOOKING EAST: taken from north end BLDG. 1. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  14. 2. ELEVATION DETAIL WEST FACE BLDG. 28B, 27. Fafnir ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. ELEVATION DETAIL WEST FACE BLDG. 28B, 27. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  15. 12. FIRST FLOOR BLD 28B: DETAIL SOLVENT PUMPS. Fafnir ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. FIRST FLOOR BLD 28B: DETAIL SOLVENT PUMPS. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  16. 10. FIRST FLOOR BLDG. 28B: DETAIL FLARED COLUMN. Fafnir ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. FIRST FLOOR BLDG. 28B: DETAIL FLARED COLUMN. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  17. Dissecting aneurysm of arch and descending thoracic aorta presenting as a left sided hemorrhagic pleural effusion

    PubMed Central

    Shamim, Shelley; Thakur, Sumitra Basu; Sengupta, Amitava; Bhattacharyya, Sujit Kumar; Sit, Niranjan

    2010-01-01

    The most common cause of massive hemorrhagic effusion is malignancy. Herein we present a case of dissecting aneurysm of descending thoracic aorta presenting initially with shortness of breath due to left sided massive pleural effusion. Effusion was hemorrhagic in nature with high hematocrit value. CT scan of thorax with CT angiogram was done and that revealed the diagnosis. PMID:21139725

  18. Clinical value of CT-based preoperative software assisted lung lobe volumetry for predicting postoperative pulmonary function after lung surgery

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Beyer, Florian; Hoffknecht, Petra; Dicken, Volker; Kuhnigk, Jan-Martin; Lange, Tobias; Thomas, Michael; Heindel, Walter

    2005-04-01

    This study was aimed to evaluate a morphology-based approach for prediction of postoperative forced expiratory volume in one second (FEV1) after lung resection from preoperative CT scans. Fifteen Patients with surgically treated (lobectomy or pneumonectomy) bronchogenic carcinoma were enrolled in the study. A preoperative chest CT and pulmonary function tests before and after surgery were performed. CT scans were analyzed by prototype software: automated segmentation and volumetry of lung lobes was performed with minimal user interaction. Determined volumes of different lung lobes were used to predict postoperative FEV1 as percentage of the preoperative values. Predicted FEV1 values were compared to the observed postoperative values as standard of reference. Patients underwent lobectomy in twelve cases (6 upper lobes; 1 middle lobe; 5 lower lobes; 6 right side; 6 left side) and pneumonectomy in three cases. Automated calculation of predicted postoperative lung function was successful in all cases. Predicted FEV1 ranged from 54% to 95% (mean 75% +/- 11%) of the preoperative values. Two cases with obviously erroneous LFT were excluded from analysis. Mean error of predicted FEV1 was 20 +/- 160 ml, indicating absence of systematic error; mean absolute error was 7.4 +/- 3.3% respective 137 +/- 77 ml/s. The 200 ml reproducibility criterion for FEV1 was met in 11 of 13 cases (85%). In conclusion, software-assisted prediction of postoperative lung function yielded a clinically acceptable agreement with the observed postoperative values. This method might add useful information for evaluation of functional operability of patients with lung cancer.

  19. 7. ELEVATION SOUTH FACE BLDG. 28B, 28, 28A. Fafnir ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. ELEVATION SOUTH FACE BLDG. 28B, 28, 28A. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  20. 31. ELEVATION WEST FACE BLDG. 27, SEE SERVICE DRIVE TUNNEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. ELEVATION WEST FACE BLDG. 27, SEE SERVICE DRIVE TUNNEL INTO COURTYARD. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  1. 1. OVERVIEW LOOKING EAST: overview taken from south end BLDG. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. OVERVIEW LOOKING EAST: overview taken from south end BLDG. 1. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  2. 36. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" AIR FILTERS LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" AIR FILTERS LOOKING SOUTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  3. 35. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" DINING AREA LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" DINING AREA LOOKING WEST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  4. 34. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" ENTRANCE CORRIDOR LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" ENTRANCE CORRIDOR LOOKING SOUTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  5. Variations in Branching Pattern of Renal Artery in Kidney Donors Using CT Angiography.

    PubMed

    Munnusamy, Kumaresan; Kasirajan, Sankaran Ponnusamy; Gurusamy, Karthikeyan; Raghunath, Gunapriya; Bolshetty, Shilpakala Leshappa; Chakrabarti, Sudakshina; Annadurai, Priyadarshini; Miyajan, Zareena Begum

    2016-03-01

    Each kidney is supplied by a single renal artery originating from abdominal aorta. Since there are lots of renal surgeries happening now-a-days, it becomes mandatory for the surgeons to understand the abnormality and variations in the renal vasculature. To study the variations in the branching pattern of renal artery for the presence of early division and accessory renal artery in Indian kidney donors using CT angiography. The CT angiogram images of 100 normal individuals willing for kidney donation were analysed for early divisions and occurrence of accessory renal artery. A 51% of kidney donors showed variation in the renal artery. Out of 51% variations 38 individuals had accessory renal artery and 13 individuals had early division of renal artery. The distribution of accessory renal artery was equal on both sides (13% on right and left) and 12% of individuals had accessory renal artery on both sides. Out of 13% earlier divisions, 5% was on right side, 7% was on left side and 1% was on both sides. This study concludes that 51% of kidney donors had renal artery variations. Hence, awareness of variations by evaluating the donors is a must before renal transplantation, urological procedures and angiographic interventions.

  6. 20. FIFTH FLOOR BLDG. 28A, VIEW SOUND TEST ROOMS LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. FIFTH FLOOR BLDG. 28A, VIEW SOUND TEST ROOMS LOOKING NORTHEAST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  7. 28. ELEVATION BLDG. 45, IN COURTYARD FORMED BY BLDG. 29, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. ELEVATION BLDG. 45, IN COURTYARD FORMED BY BLDG. 29, 27, AND 28 LOOKING NORTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  8. 23. FIFTH FLOOR BLDG. 28B, DETAIL WOOD BLOCK FLOORING LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. FIFTH FLOOR BLDG. 28B, DETAIL WOOD BLOCK FLOORING LOOKING WEST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  9. 4. OVERVIEW LOOKING NORTHEAST, BLD 5 RIGHT FOREGROUND, BLDG. 44/16 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. OVERVIEW LOOKING NORTHEAST, BLD 5 RIGHT FOREGROUND, BLDG. 44/16 LEFT FOREGROUND. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  10. 6. ELEVATION WEST AND SOUTH FACES BLDG. 28B, 28, 28A. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. ELEVATION WEST AND SOUTH FACES BLDG. 28B, 28, 28A. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  11. 11. FIRST FLOOR BLDG. 28B: OVERVIEW SOLVENT PUMPS AND HEATING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. FIRST FLOOR BLDG. 28B: OVERVIEW SOLVENT PUMPS AND HEATING LOOKING WEST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  12. 18. FOURTH FLOOR BLDG. 28, RAISED CONCRETE SLAB FLOOR WITH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. FOURTH FLOOR BLDG. 28, RAISED CONCRETE SLAB FLOOR WITH BLOCKS AND PULLEYS OVERHEAD LOOKING NORTHEAST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  13. 22. FIFTH FLOOR BLDG. 28A, DETAIL DOUBLE DOORS SOUND TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. FIFTH FLOOR BLDG. 28A, DETAIL DOUBLE DOORS SOUND TEST ROOM LOOKING NORTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  14. 17. THIRD FLOOR BLDG. 28B, DETAIL ACOUSTIC TILE CEILING LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. THIRD FLOOR BLDG. 28B, DETAIL ACOUSTIC TILE CEILING LOOKING SOUTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  15. 21. FIFTH FLOOR BLDG. 28A, ELEVATION WEST END SOUND TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. FIFTH FLOOR BLDG. 28A, ELEVATION WEST END SOUND TEST ROOM. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  16. 24. FIFTH FLOOR BLDG. 28B, DETAIL WOOD BLOCK FLOORING LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. FIFTH FLOOR BLDG. 28B, DETAIL WOOD BLOCK FLOORING LOOKING NORTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  17. 19. FOURTH FLOOR BLDG. 28, DETAIL BLOCKS, PULLEYS, AND ELECTRIC ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. FOURTH FLOOR BLDG. 28, DETAIL BLOCKS, PULLEYS, AND ELECTRIC MOTOR LOOKING EAST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  18. Automatic segmentation of the liver using multi-planar anatomy and deformable surface model in abdominal contrast-enhanced CT images

    NASA Astrophysics Data System (ADS)

    Jang, Yujin; Hong, Helen; Chung, Jin Wook; Yoon, Young Ho

    2012-02-01

    We propose an effective technique for the extraction of liver boundary based on multi-planar anatomy and deformable surface model in abdominal contrast-enhanced CT images. Our method is composed of four main steps. First, for extracting an optimal volume circumscribing a liver, lower and side boundaries are defined by positional information of pelvis and rib. An upper boundary is defined by separating the lungs and heart from CT images. Second, for extracting an initial liver volume, optimal liver volume is smoothed by anisotropic diffusion filtering and is segmented using adaptively selected threshold value. Third, for removing neighbor organs from initial liver volume, morphological opening and connected component labeling are applied to multiple planes. Finally, for refining the liver boundaries, deformable surface model is applied to a posterior liver surface and missing left robe in previous step. Then, probability summation map is generated by calculating regional information of the segmented liver in coronal plane, which is used for restoring the inaccurate liver boundaries. Experimental results show that our segmentation method can accurately extract liver boundaries without leakage to neighbor organs in spite of various liver shape and ambiguous boundary.

  19. SU-E-I-15: Quantitative Evaluation of Dose Distributions From Axial, Helical and Cone-Beam CT Imaging by Measurement Using a Two-Dimensional Diode-Array Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chacko, M; Aldoohan, S; Sonnad, J

    2015-06-15

    Purpose: To evaluate quantitatively dose distributions from helical, axial and cone-beam CT clinical imaging techniques by measurement using a two-dimensional (2D) diode-array detector. Methods: 2D-dose distributions from selected clinical protocols used for axial, helical and cone-beam CT imaging were measured using a diode-array detector (MapCheck2). The MapCheck2 is composed from solid state diode detectors that are arranged in horizontal and vertical lines with a spacing of 10 mm. A GE-Light-Speed CT-simulator was used to acquire axial and helical CT images and a kV on-board-imager integrated with a Varian TrueBeam-STx machine was used to acquire cone-beam CT (CBCT) images. Results: Themore » dose distributions from axial, helical and cone-beam CT were non-uniform over the region-of-interest with strong spatial and angular dependence. In axial CT, a large dose gradient was measured that decreased from lateral sides to the middle of the phantom due to large superficial dose at the side of the phantom in comparison with larger beam attenuation at the center. The dose decreased at the superior and inferior regions in comparison to the center of the phantom in axial CT. An asymmetry was found between the right-left or superior-inferior sides of the phantom which possibly to angular dependence in the dose distributions. The dose level and distribution varied from one imaging technique into another. For the pelvis technique, axial CT deposited a mean dose of 3.67 cGy, helical CT deposited a mean dose of 1.59 cGy, and CBCT deposited a mean dose of 1.62 cGy. Conclusions: MapCheck2 provides a robust tool to measure directly 2D-dose distributions for CT imaging with high spatial resolution detectors in comparison with ionization chamber that provides a single point measurement or an average dose to the phantom. The dose distributions measured with MapCheck2 consider medium heterogeneity and can represent specific patient dose.« less

  20. 16. THIRD FLOOR BLDG. 28A, DETAIL CUTOUT IN FLOOR FOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. THIRD FLOOR BLDG. 28A, DETAIL CUTOUT IN FLOOR FOR WOOD BLOCK FLOORING LOOKING EAST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  1. J{sub IC} evaluation of the smooth and the side-grooved CT specimen in the reactor pressure vessel steel (SA508-3)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oh, S.W.; Lim, M.B.; Kim, T.H.

    1993-12-31

    The elastic-plastic fracture toughness J{sub IC} of SA508-3 forging steel was investigated by using CT-type specimens. The thickness of the smooth specimen is B{sub 0} = 25.4 mm and the side groove specimen is B{sub N} = 20.4 mm and the side groove deep is S{center_dot}G = [(B{sub 0} {minus} B{sub N})/B{sub 0}] {times} 100 = 19.7% and the groove angle is 90{degree}. The J{sub IC} tests estimated according to the method proposed in the ASTM E813-81 and JSME S001-81. The side-grooved specimen have the advantage of J{sub IC} estimation, it is much easier to determine the onset of ductilemore » tearing by the R-curve method and it improved accuracy and scatter of the toughness values thus determined, provided all the size-requirements for the specimen prescribed in the JSME method were satisfied. But it is difficult to find by the ASTM method. The critical stretched zone width (SZW{sub C}) of the side-grooved specimens found to be smaller than that previously determined for the standard CT specimens without side-grooves. This was attributed to higher triaxiality produced by the side-grooves. The stretched zone width method gave slightly larger J{sub IC} values than those by the R-curve method for SA508-3, as has been observed for the standard specimen without side-groove.« less

  2. CT-based manual segmentation and evaluation of paranasal sinuses.

    PubMed

    Pirner, S; Tingelhoff, K; Wagner, I; Westphal, R; Rilk, M; Wahl, F M; Bootz, F; Eichhorn, Klaus W G

    2009-04-01

    Manual segmentation of computed tomography (CT) datasets was performed for robot-assisted endoscope movement during functional endoscopic sinus surgery (FESS). Segmented 3D models are needed for the robots' workspace definition. A total of 50 preselected CT datasets were each segmented in 150-200 coronal slices with 24 landmarks being set. Three different colors for segmentation represent diverse risk areas. Extension and volumetric measurements were performed. Three-dimensional reconstruction was generated after segmentation. Manual segmentation took 8-10 h for each CT dataset. The mean volumes were: right maxillary sinus 17.4 cm(3), left side 17.9 cm(3), right frontal sinus 4.2 cm(3), left side 4.0 cm(3), total frontal sinuses 7.9 cm(3), sphenoid sinus right side 5.3 cm(3), left side 5.5 cm(3), total sphenoid sinus volume 11.2 cm(3). Our manually segmented 3D-models present the patient's individual anatomy with a special focus on structures in danger according to the diverse colored risk areas. For safe robot assistance, the high-accuracy models represent an average of the population for anatomical variations, extension and volumetric measurements. They can be used as a database for automatic model-based segmentation. None of the segmentation methods so far described provide risk segmentation. The robot's maximum distance to the segmented border can be adjusted according to the differently colored areas.

  3. A Model of Regularization Parameter Determination in Low-Dose X-Ray CT Reconstruction Based on Dictionary Learning.

    PubMed

    Zhang, Cheng; Zhang, Tao; Zheng, Jian; Li, Ming; Lu, Yanfei; You, Jiali; Guan, Yihui

    2015-01-01

    In recent years, X-ray computed tomography (CT) is becoming widely used to reveal patient's anatomical information. However, the side effect of radiation, relating to genetic or cancerous diseases, has caused great public concern. The problem is how to minimize radiation dose significantly while maintaining image quality. As a practical application of compressed sensing theory, one category of methods takes total variation (TV) minimization as the sparse constraint, which makes it possible and effective to get a reconstruction image of high quality in the undersampling situation. On the other hand, a preliminary attempt of low-dose CT reconstruction based on dictionary learning seems to be another effective choice. But some critical parameters, such as the regularization parameter, cannot be determined by detecting datasets. In this paper, we propose a reweighted objective function that contributes to a numerical calculation model of the regularization parameter. A number of experiments demonstrate that this strategy performs well with better reconstruction images and saving of a large amount of time.

  4. Establishment of metrological traceability in porosity measurements by x-ray computed tomography

    NASA Astrophysics Data System (ADS)

    Hermanek, Petr; Carmignato, Simone

    2017-09-01

    Internal porosity is an inherent phenomenon to many manufacturing processes, such as casting, additive manufacturing, and others. Since these defects cannot be completely avoided by improving production processes, it is important to have a reliable method to detect and evaluate them accurately. The accurate evaluation becomes even more important concerning current industrial trends to minimize size and weight of products on one side, and enhance their complexity and performance on the other. X-ray computed tomography (CT) has emerged as a promising instrument for holistic porosity measurements offering several advantages over equivalent methods already established in the detection of internal defects. The main shortcomings of the conventional techniques pertain to too general information about total porosity content (e.g. Archimedes method) or the destructive way of testing (e.g. microscopy of cross-sections). On the contrary, CT is a nondestructive technique providing complete information about size, shape and distribution of internal porosity. However, due to the lack of international standards and the fact that it is relatively a new measurement technique, CT as a measurement technology has not yet reached maturity. This study proposes a procedure for the establishment of measurement traceability in porosity measurements by CT including the necessary evaluation of measurement uncertainty. The traceability transfer is carried out through a novel reference standard calibrated by optical and tactile coordinate measuring systems. The measurement uncertainty is calculated following international standards and guidelines. In addition, the accuracy of porosity measurements by CT with the associated measurement uncertainty is evaluated using the reference standard.

  5. Variations in Branching Pattern of Renal Artery in Kidney Donors Using CT Angiography

    PubMed Central

    Munnusamy, Kumaresan; Gurusamy, Karthikeyan; Raghunath, Gunapriya; Bolshetty, Shilpakala Leshappa; Chakrabarti, Sudakshina; Annadurai, Priyadarshini; Miyajan, Zareena Begum

    2016-01-01

    Introduction Each kidney is supplied by a single renal artery originating from abdominal aorta. Since there are lots of renal surgeries happening now-a-days, it becomes mandatory for the surgeons to understand the abnormality and variations in the renal vasculature. Aim To study the variations in the branching pattern of renal artery for the presence of early division and accessory renal artery in Indian kidney donors using CT angiography. Materials and Methods The CT angiogram images of 100 normal individuals willing for kidney donation were analysed for early divisions and occurrence of accessory renal artery. Results A 51% of kidney donors showed variation in the renal artery. Out of 51% variations 38 individuals had accessory renal artery and 13 individuals had early division of renal artery. The distribution of accessory renal artery was equal on both sides (13% on right and left) and 12% of individuals had accessory renal artery on both sides. Out of 13% earlier divisions, 5% was on right side, 7% was on left side and 1% was on both sides. Conclusion This study concludes that 51% of kidney donors had renal artery variations. Hence, awareness of variations by evaluating the donors is a must before renal transplantation, urological procedures and angiographic interventions. PMID:27134847

  6. 24. Left side view of equipment used to clean and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. Left side view of equipment used to clean and wash sand prior to reuse on the sand filter bed. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  7. 23. Right side view of equipment used to clean and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. Right side view of equipment used to clean and wash sand prior to reuse on the sand filter bed. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  8. Clinical importance of re-interpretation of PET/CT scanning in patients referred to a tertiary care medical centre.

    PubMed

    Löfgren, Johan; Loft, Annika; Barbosa de Lima, Vinicius Araújo; Østerlind, Kell; von Benzon, Eric; Højgaard, Liselotte

    2017-03-01

    To evaluate, in a controlled prospective manner with double-blind read, whether there are differences in interpretations of PET/CT scans at our tertiary medical centre, Rigshospitalet, compared to the external hospitals. Ninety consecutive patients referred to our department who had an external F-18-FDG PET/CT scan were included. Only information that had been available at the time of the initial reading at the external hospital was available at re-interpretation. Teams with one radiologist and one nuclear medicine physician working side by side performed the re-interpretation in consensus. Two oncologists subsequently and independently compared the original reports with the re-interpretation reports. In case of 'major discordance', the oncologists assessed the respective reports validities. The interpretations were graded as 'accordant' in 43 patients (48%), 'minor discordance' in 30 patients (33%) and 'major discordance' in 17 patients (19%). In 11 (65%) of the 17 cases graded as 'major discordance', it was possible to determine which report that was most correct. In 9 of these 11 cases (82%), the re-interpretation was most correct; in one case, the original report and in another case, both interpretations were incorrect. Major discordant interpretations were frequent [19% (17 of 90 cases)]. In those cases where follow-up could assess the validity, the re-interpretation at Rigshospitalet was most correct in 9 of 11 cases (82%), indicating that there is a difference in expertise in interpreting PET/CT at a tertiary referral hospital compared to primary local hospitals. © 2015 The Authors. Clinical Physiology and Functional Imaging published by John Wiley & Sons Ltd on behalf of Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  9. Patterns of nodal metastases on 18F-FDG PET/CT in patients with esophageal squamous cell carcinoma are useful to guide treatment planning of radiotherapy.

    PubMed

    Liu, Chia-Ju; Cheng, Jason Chia-Hsien; Lee, Jang-Ming; Cheng, Mei-Fang; Tzen, Kai-Yuan; Yen, Ruoh-Fang

    2015-05-01

    The aim of the study was to examine the patterns of lymph node metastases from esophageal squamous cell carcinoma (ESCC) and compare the laterality of lymphatic metastasis in cervical, supraclavicular, and paratracheal areas using F-FDG PET/CT. The data of 75 patients who underwent F-FDG PET/CT for staging of ESCC between January 2011 and March 2012 were reviewed. Fourteen groups of lymph nodes from the neck to abdomen were defined. Lateralization of the upper thoracic lymph nodes was defined in reference to the midline of the trachea. Frequencies of positive lymph nodes were used to determine the pattern of lymphatic spread and compare the lateralization of metastases in the cervical and upper thoracic regions. The right paratracheal region was the most frequent site of metastasis among all patients. Left paratracheal and paragastric nodes were more frequent in upper and lower third ESCC, respectively. Upward and downward lymphatic spread was equal in mid third ESCC. In all patients, there was a trend toward more frequent lymph node metastasis on the right side than the left side for the supraclavicular and paratracheal regions. Further stratified analysis with tumor location found that right paratracheal node metastasis was significantly associated with mid third ESCC (P = 0.03). Remote nodal metastasis was found in 10.5% of patients with upper third ESCC and 13% of patients with lower third ESCC, respectively. Remote nodal metastasis was associated with higher SUV of the primary tumor (P = 0.02) and worse survival (P = 0.03). Receiver operating characteristic analysis showed a cutoff SUV of 14.8 for predicting remote lymph node metastases. PET/CT provides important information before radiotherapy planning. Mid and lower third ESCC tends to metastasize to the right paratracheal/supraclavicular lymph nodes. Remote nodal metastases on PET/CT correlated with higher primary tumor SUV and worse survival.

  10. The classification of frontal sinus pneumatization patterns by CT-based volumetry.

    PubMed

    Yüksel Aslier, Nesibe Gül; Karabay, Nuri; Zeybek, Gülşah; Keskinoğlu, Pembe; Kiray, Amaç; Sütay, Semih; Ecevit, Mustafa Cenk

    2016-10-01

    We aimed to define the classification of frontal sinus pneumatization patterns according to three-dimensional volume measurements. Datasets of 148 sides of 74 dry skulls were generated by the computerized tomography-based volumetry to measure frontal sinus volumes. The cutoff points for frontal sinus hypoplasia and hyperplasia were tested by ROC curve analysis and the validity of the diagnostic points was measured. The overall frequencies were 4.1, 14.2, 37.2 and 44.5 % for frontal sinus aplasia, hypoplasia, medium size and hyperplasia, respectively. The aplasia was bilateral in all three skulls. Hypoplasia was seen 76 % at the right side and hyperplasia was seen 56 % at the left side. The cutoff points for diagnosing frontal sinus hypoplasia and hyperplasia were '1131.25 mm(3)' (95.2 % sensitivity and 100 % specificity) and '3328.50 mm(3)' (88 % sensitivity and 86 % specificity), respectively. The findings provided in the present study, which define frontal sinus pneumatization patterns by CT-based volumetry, proved that two opposite sides of the frontal sinuses are asymmetric and three-dimensional classification should be developed by CT-based volumetry, because two-dimensional evaluations lack depth measurement.

  11. Anatomical Variant of Atlas : Arcuate Foramen, Occpitalization of Atlas, and Defect of Posterior Arch of Atlas.

    PubMed

    Kim, Myoung Soo

    2015-12-01

    We sought to examine anatomic variations of the atlas and the clinical significance of these variations. We retrospectively reviewed 1029 cervical 3-dimensional (3D) CT images. Cervical 3D CT was performed between November 2011 and August 2014. Arcuate foramina were classified as partial or complete and left and/or right. Occipitalization of the atlas was classified in accordance with criteria specified by Mudaliar et al. Posterior arch defects of the atlas were classified in accordance with criteria specified by Currarino et al. One hundred and eight vertebrae (108/1029, 10.5%) showed an arcuate foramen. Bilateral arcuate foramina were present in 41 of these vertebrae and the remaining 67 arcuate foramina were unilateral (right 31, left 36). Right-side arcuate foramina were partial on 18 sides and complete on 54 sides. Left-side arcuate foramina were partial on 24 sides and complete on 53 sides. One case of atlas assimilation was found. Twelve patients (12/1029, 1.17%) had a defect of the atlantal posterior arch. Nine of these patients (9/1029, 0.87%) had a type A posterior arch defect. We also identified one type B, one type D, and one type E defect. Preoperative diagnosis of occipitalization of the atlas and arcuate foramina using 3D CT is of paramount importance in avoiding neurovascular injury during surgery. It is important to be aware of posterior arch defects of the atlas because they may be misdiagnosed as a fracture.

  12. The diagnostic value of single-photon emission computed tomography/computed tomography for severe sacroiliac joint dysfunction.

    PubMed

    Tofuku, Katsuhiro; Koga, Hiroaki; Komiya, Setsuro

    2015-04-01

    We aimed to evaluate the value of single-photon emission computed tomography (SPECT)/computed tomography (CT) for the diagnosis of sacroiliac joint (SIJ) dysfunction. SPECT/CT was performed in 32 patients with severe SIJ dysfunction, who did not respond to 1-year conservative treatment and had a score of >4 points on a 10-cm visual analog scale. We investigated the relationship between the presence of severe SIJ dysfunction and tracer accumulation, as confirmed by SPECT/CT. In cases of bilateral SIJ dysfunction, we also compared the intensity of tracer accumulation on each side. Moreover, we examined the relationship between the intensity of tracer accumulation and the different treatments the patients subsequently received. All 32 patients with severe SIJ dysfunction had tracer accumulation with a standardized uptake value (SUV) of >2.2 (mean SUV 4.7). In the 19 patients with lateralized symptom intensity, mean SUVs of the dominant side were significantly higher than those of the nondominant side. In 10 patients with no lateralization, the difference in the SUVs between sides was <0.6. Patients exhibiting higher levels of tracer accumulation required more advanced treatment. Patients with higher levels of tracer accumulation had greater symptom severity and also required more advanced treatment. Thus, we believe that SPECT/CT may be a suitable supplementary diagnostic modality for SIJ dysfunction as well as a useful technique for predicting the prognosis of this condition.

  13. The side effects and complications of percutaneous iodine-125 seeds implantation under CT-guide for patients with advanced pancreatic cancer.

    PubMed

    Lv, Wei-Fu; Lu, Dong; Xiao, Jing-Kun; Mukhiya, Gauri; Tan, Zhong-Xiao; Cheng, De-Lei; Zhou, Chun-Ze; Zhang, Xing-Min; Zhang, Zheng-Feng; Hou, Chang-Long

    2017-12-01

    The present study investigates the side effects and complications of computed tomography (CT)-guided percutaneous iodine-125 (I-125) seeds implantation for advanced pancreatic cancer. The clinical data were retrospectively analyzed for patients treated with implantation of I-125 seeds under CT-guide in our hospital from May 2010 to April 2015. The side effects and complications were collected and their possible reasons were analyzed. A total of 78 patients were enrolled. The side effects were categorized as fever in 29 cases (37.18%), abdominal pain in 26 cases (33.33%), nausea and vomiting in 9 cases (11.54%), diarrhea in 5 cases (6.41%), and constipation in 4 cases (5.13%). Complications were composed of pancreatitis in 9 cases (11.54%), infection in 5 cases (6.41%), seed migration in 2 cases (2.56%), intestinal perforation in 1 case (1.28%), and intestinal obstruction in 1 case. The incidence of complication was 23.08% (18/78). The difference in incidence of complication was statistically significant between patients implanted with ≤27 seeds and those with >27 seeds (P = .032). The side effects and complications frequently occur in implantation of I-125 seeds for patients with advanced pancreatic cancer. More concern should be given to the patients treated by this technique. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  14. Incidence of retrorenal colon during percutaneous nephrolithotomy

    PubMed Central

    Balasar, Mehmet; Kandemir, Abdülkadir; Poyraz, Necdet; Unal, Yunus; Ozturk, Ahmet

    2015-01-01

    Objective The aim of this study was to investigate retrorenal colon incidence in percutaneous nephrolithotomy (PNL) interventions made in our clinic. Materials and Methods Clinical data of 804 PNL patients, accumulated over a 7 year period (2006-2012), was surveyed. The patient files were reviewed retrospectively, and only those who had abdominal computed tomography (CT) images before PNL intervention were included in the study. In the CT images, the position of both the ascending and descending colon in relation to the right and left kidneys were evaluated. Results According to our hospital reports, 394 patients with CT images were included in the present study 27 patients (6.9%) had retrorenal colon, of which 18 (4.6%) were on the left side, 4 (1.0%) on the right side and 5 (1.3%) had bilateral retrorenal colons. Colonic perforation complication was seen only in two patients and the colonic perforation rate was 0.3%. These two cases had no CT images. Conclusions PNL, in the process of becoming the standard treatment modality, is a safe and reliable technique for renal stone treatment. Colonic injury should be taken into consideration during PNL interventions of the lower pole of the kidney (especially on the left side) due to the location of retrorenal colon. PMID:26005968

  15. 7. VIEW SOUTHEAST, SHOWING WEST SIDE FROM LAND, WITH WASTE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW SOUTHEAST, SHOWING WEST SIDE FROM LAND, WITH WASTE PAPER BUNDLED ON DOCK, AWAITING LOADING ONTO ODIGITRIA B - Connecticut State Pier, State Pier Road at Thames River, New London, New London County, CT

  16. Carpal bone movements in gripping action of the giant panda (Ailuropoda melanoleuca)

    PubMed Central

    ENDO, HIDEKI; SASAKI, MOTOKI; HAYASHI, YOSHIHIRO; KOIE, HIROSHI; YAMAYA, YOSHIKI; KIMURA, JUNPEI

    2001-01-01

    The movement of the carpal bones in gripping was clarified in the giant panda (Ailuropoda melanoleuca) by means of macroscopic anatomy, computed tomography (CT) and related 3-dimensional (3-D) volume rendering techniques. In the gripping action, 3-D CT images demonstrated that the radial and 4th carpal bones largely rotate or flex to the radial and ulnar sides respectively. This indicates that these carpal bones on both sides enable the panda to flex the palm from the forearm and to grasp objects by the manipulation mechanism that includes the radial sesamoid. In the macroscopic observations, we found that the smooth articulation surfaces are enlarged between the radial carpal and the radius on the radial side, and between the 4th and ulnar carpals on the ulnar side. The panda skilfully grasps using a double pincer-like apparatus with the huge radial sesamoid and accessory carpal. PMID:11273049

  17. Sci—Thur AM: YIS - 01: Dosimetric Analysis of Respiratory Induced Cardiac Intrafraction Motion in Left-sided Breast Cancer Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El-Sherif, O; Xhaferllari, I; Patrick, J

    2014-08-15

    Introduction: Long-term cardiac side effects in left-sided breast cancer patients (BREL) after post-operative radiotherapy has become one of the most debated issues in radiation oncology. Through breathing-adapted radiotherapy the volume of the heart exposed to radiation can be significantly reduced by delivering the radiation only at the end of inspiration phase of the respiratory cycle, this is referred to as inspiration gating (IG). The purpose of this study is to quantify the potential reduction in cardiac exposure during IG compared to conventional BREL radiotherapy and to assess the dosimetric impact of cardiac motion due to natural breathing. Methods: 24 BRELmore » patients treated with tangential parallel opposed photon beams were included in this study. All patients received a standard fast helical planning CT (FH-CT) and a 4D-CT. Treatment plans were created on the FH-CT using a clinical treatment planning system. The original treatment plan was then superimposed onto the end of inspiration CT and all 10 phases of the 4D-CT to quantify the dosimetric impact of respiratory motion and IG through 4D dose accumulation. Results: Through IG the mean dose to the heart, left ventricle, and left anterior descending artery (LAD) can be reduced in comparison to the clinical standard BREL treatment by as much as 8.39%, 10.11%, and 13.71% respectively (p < 0.05). Conclusion: Failure to account for respiratory motion can lead to under or overestimation in the calculated DVH for the heart, and it's sub-structures. IG can reduce cardiac exposure especially to the LAD during BREL radiotherapy.« less

  18. Developing an interactive teleradiology system for SARS diagnosis

    NASA Astrophysics Data System (ADS)

    Sun, Jianyong; Zhang, Jianguo; Zhuang, Jun; Chen, Xiaomeng; Yong, Yuanyuan; Tan, Yongqiang; Chen, Liu; Lian, Ping; Meng, Lili; Huang, H. K.

    2004-04-01

    Severe acute respiratory syndrome (SARS) is a respiratory illness that had been reported in Asia, North America, and Europe in last spring. Most of the China cases of SARS have occurred by infection in hospitals or among travelers. To protect the physicians, experts and nurses from the SARS during the diagnosis and treatment procedures, the infection control mechanisms were built in SARS hospitals. We built a Web-based interactive teleradiology system to assist the radiologists and physicians both in side and out side control area to make image diagnosis. The system consists of three major components: DICOM gateway (GW), Web-based image repository server (Server), and Web-based DICOM viewer (Viewer). This system was installed and integrated with CR, CT and the hospital information system (HIS) in Shanghai Xinhua hospital to provide image-based ePR functions for SARS consultation between the radiologists, physicians and experts inside and out side control area. The both users inside and out side the control area can use the system to process and manipulate the DICOM images interactively, and the system provide the remote control mechanism to synchronize their operations on images and display.

  19. Usefulness of Single Photon Emission Computed Tomography/Computed Tomography Fusion-Hybrid Imaging to Evaluate Coronary Artery Disorders in Patients with a History of Kawasaki Disease.

    PubMed

    Abe, Masanori; Fukazawa, Ryuji; Ogawa, Shunichi; Watanabe, Makoto; Fukushima, Yoshimitsu; Kiriyama, Tomonari; Hayashi, Hiromitsu; Itoh, Yasuhiko

    2016-01-01

    The coronary arterial lesions of Kawasaki disease are mainly dilative lesions, aneurysms, and stenotic lesions formed before, after, and between aneurysms; these lesions develop in multiple branches resulting in complex coronary hemodynamics. Diagnosis of myocardial ischemia and infarction and evaluation of the culprit coronary arteries and regions is critical to evaluating the treatment and prognosis of patients. This study used hybrid imaging, in which multidetector computed tomographic (CT) images for coronary CT angiography (CCTA) and stress myocardial perfusion single-photon emission CT (SPECT) images were fused. We investigated the diagnosis of blood vessels and regions responsible for myocardial ischemia and infarction in patients with complex coronary arterial lesions; in addition, we evaluated myocardial lesions that developed directly under giant coronary artery aneurysms. The subjects were 17 patients with Kawasaki disease with multiple coronary arterial lesions (median age, 18.0 years; 16 male). Both CCTA using 64-row CT and adenosine-loading myocardial SPECT were performed. Three branches, the right coronary artery (RCA), left anterior descending branch (LAD), and left circumflex branch, were evaluated with the conventional side-by-side interpretation, in which the images were lined up for diagnosis, and hybrid imaging, in which the CCTA and SPECT images were fused with computer processing. In addition, the myocardial lesions directly under giant coronary artery aneurysms were investigated with fusion imaging. Images sufficient for evaluation were acquired in all 17 patients. In the RCA, coronary arterial lesions were detected with CCTA in 16 patients. The evaluations were consistent between the side-by-side and fusion interpretation in 14 patients, and the blood vessel responsible for the myocardial ischemic region was identified in 2 patients. In the left circumflex branch, coronary arterial lesions were confirmed with 3-dimensional CT in 5 patients, and the the culprit coronary arteries for myocardial ischemia/infarction were confirmed with the fusion interpretation but not with the side-by-side interpretation. In the LAD, coronary arterial lesions were present in all patients, and the diagnosis was made with the fusion interpretation in 10 patients. In the LAD, small-range infarct lesions were detected directly under the giant coronary artery aneurysm in 8 patients, but were not confirmed with the side-by-side interpretation. Fusion imaging was capable of accurately evaluating myocardial ischemia/infarction as cardiovascular sequelae of Kawasaki disease and confirming the culprit coronary arteries. In addition, analysis of fusion images confirmed that small-range infarct lesions were concomitantly present directly under giant coronary artery aneurysms in the anterior descending coronary artery.

  20. A Model of Regularization Parameter Determination in Low-Dose X-Ray CT Reconstruction Based on Dictionary Learning

    PubMed Central

    Zhang, Cheng; Zhang, Tao; Li, Ming; Lu, Yanfei; You, Jiali; Guan, Yihui

    2015-01-01

    In recent years, X-ray computed tomography (CT) is becoming widely used to reveal patient's anatomical information. However, the side effect of radiation, relating to genetic or cancerous diseases, has caused great public concern. The problem is how to minimize radiation dose significantly while maintaining image quality. As a practical application of compressed sensing theory, one category of methods takes total variation (TV) minimization as the sparse constraint, which makes it possible and effective to get a reconstruction image of high quality in the undersampling situation. On the other hand, a preliminary attempt of low-dose CT reconstruction based on dictionary learning seems to be another effective choice. But some critical parameters, such as the regularization parameter, cannot be determined by detecting datasets. In this paper, we propose a reweighted objective function that contributes to a numerical calculation model of the regularization parameter. A number of experiments demonstrate that this strategy performs well with better reconstruction images and saving of a large amount of time. PMID:26550024

  1. Traumatic diaphragmatic injury: a review of CT signs and the difference between blunt and penetrating injury

    PubMed Central

    Panda, Ananya; Kumar, Atin; Gamanagatti, Shivanand; Patil, Aruna; Kumar, Subodh; Gupta, Amit

    2014-01-01

    PURPOSE We aimed to present the frequency of computed tomography (CT) signs of diaphragmatic rupture and the differences between blunt and penetrating trauma. MATERIALS AND METHODS The CT scans of 23 patients with surgically proven diaphragmatic tears (both blunt and penetrating) were retrospectively reviewed for previously described CT signs of diaphragmatic injuries. The overall frequency of CT signs was reported; frequency of signs in right- and left-sided injuries and blunt and penetrating trauma were separately tabulated and statistically compared. RESULTS The discontinuous diaphragm sign was the most common sign, observed in 95.7% of patients, followed by diaphragmatic thickening (69.6%). While the dependent viscera sign and collar sign were exclusively observed in blunt-trauma patients, organ herniation (P = 0.05) and dangling diaphragm (P = 0.0086) signs were observed significantly more often in blunt trauma than in penetrating trauma. Contiguous injury on either side of the diaphragm was observed more often in penetrating trauma (83.3%) than in blunt trauma (17.7%). CONCLUSION Knowledge of the mechanism of injury and familiarity with all CT signs of diaphragmatic injury are necessary to avoid a missed diagnosis because there is variability in the overall occurrence of these signs, with significant differences between blunt and penetrating trauma. PMID:24412818

  2. Three-dimensional CT might be a potential evaluation modality in correction of asymmetrical masseter muscle hypertrophy by botulinum toxin injection.

    PubMed

    No, Yeon A; Ahn, Byeong Heon; Kim, Beom Joon; Kim, Myeung Nam; Hong, Chang Kwon

    2016-01-01

    For correction of this asymmetrical hypertrophy, botulinum toxin type A (BTxA) injection is one of convenient treatment modalities. Unfortunately, physical examination of masseter muscle is not enough to estimate the exact volume of muscle hypertrophy difference. Two Koreans, male and female, of bilateral masseter hypertrophy with asymmetricity were evaluated. BTxA (NABOTA(®), Daewoong, Co. Ltd., Seoul, Korea) was injected at master muscle site with total 50 U (25 U at each side) and volume change was evaluated with three-dimensional (3D) CT image analysis. Maximum reduction of masseter hypertrophy was recognized at 2-month follow-up and reduced muscle size started to restore after 3 months. Mean reduction of masseter muscle volume was 36% compared with baseline. More hypertrophied side of masseter muscle presented 42% of volume reduction at 2-month follow-up but less hypertrophied side of masseter muscle showed 30% of volume shrinkage. In conclusion, 3D CT image analysis might be the exact evaluation tool for correction of asymmetrical masseter hypertrophy by botulinum toxin injection.

  3. Inferior Vena Cava Filter from Left-Sided Superior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nair, Sujit, E-mail: drsnnair@hotmail.com; Ettles, Duncan; Robinson, Graham

    We describe the unusual case of a 71-year-old male with a history of deep vein thrombosis and recurrent multiple pulmonary embolism (PE) despite adequate anticoagulation. Computed tomography (CT) and brachiocephalic venography revealed a left-sided superior vena cava. We describe successful placement of an inferior vena cava filter via a left-sided superior vena cava.

  4. Improved image quality and diagnostic potential using ultra-high-resolution computed tomography of the lung with small scan FOV: A prospective study

    PubMed Central

    Wang, Yali; Hamal, Preeti; You, Xiaofang; Mao, Haixia; Li, Fei; Sun, Xiwen

    2017-01-01

    The aim of this study was to assess whether CT imaging using an ultra-high-resolution CT (UHRCT) scan with a small scan field of view (FOV) provides higher image quality and helps to reduce the follow-up period compared with a conventional high-resolution CT (CHRCT) scan. We identified patients with at least one pulmonary nodule at our hospital from July 2015 to November 2015. CHRCT and UHRCT scans were conducted in all enrolled patients. Three experienced radiologists evaluated the image quality using a 5-point score and made diagnoses. The paired images were displayed side by side in a random manner and annotations of scan information were removed. The following parameters including image quality, diagnostic confidence of radiologists, follow-up recommendations and diagnostic accuracy were assessed. A total of 52 patients (62 nodules) were included in this study. UHRCT scan provides a better image quality regarding the margin of nodules and solid internal component compared to that of CHRCT (P < 0.05). Readers have higher diagnostic confidence based on the UHRCT images than of CHRCT images (P<0.05). The follow-up recommendations were significantly different between UHRCT and CHRCT images (P<0.05). Compared with the surgical pathological findings, UHRCT had a relative higher diagnostic accuracy than CHRCT (P > 0.05). These findings suggest that the UHRCT prototype scanner provides a better image quality of subsolid nodules compared to CHRCT and contributes significantly to reduce the patients' follow-up period. PMID:28231320

  5. INTERIOR OF BOILER BUILDING, FIRST LEVEL, EAST SIDE, SHOWING STEAMDRIVEN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR OF BOILER BUILDING, FIRST LEVEL, EAST SIDE, SHOWING STEAM-DRIVEN PISTON PUMPS FOR FUEL OIL, CAMERA FACING EAST. - New Haven Rail Yard, Central Steam Plant and Oil Storage, Vicinity of Union Avenue, New Haven, New Haven County, CT

  6. Crowned dens syndrome diagnosed on ¹⁸F-FDG PET/CT.

    PubMed

    Monet, Antoine; Massonnat, Richard; Merino, Bertrand; Riviere, Annalisa; Richez, Christophe

    2014-12-01

    An 87-year-old woman with corticosteroid-resistant polymyalgia rheumatica underwent ¹⁸F-FDG PET/CT for suspected giant cell arteritis or neoplastic disease. FDG uptake in the immediate vicinity of the odontoid process, with a crownlike calcification, was identified on the CT scan on the posterior side of the dens, thus confirming the diagnosis of crowned dens syndrome. Because this rare syndrome is frequently misdiagnosed, nuclear physicians should be aware of the signs and symptoms of this condition, which may call for the use of PET/CT imagery.

  7. Assessment of Normal Eyeball Protrusion Using Computed Tomographic Imaging and Three-Dimensional Reconstruction in Korean Adults.

    PubMed

    Shin, Kang-Jae; Gil, Young-Chun; Lee, Shin-Hyo; Kim, Jeong-Nam; Yoo, Ja-Young; Kim, Soon-Heum; Choi, Hyun-Gon; Shin, Hyun Jin; Koh, Ki-Seok; Song, Wu-Chul

    2017-01-01

    The aim of the present study was to assess normal eyeball protrusion from the orbital rim using two- and three-dimensional images and demonstrate the better suitability of CT images for assessment of exophthalmos. The facial computed tomographic (CT) images of Korean adults were acquired in sagittal and transverse views. The CT images were used in reconstructing three-dimensional volume of faces using computer software. The protrusion distances from orbital rims and the diameters of eyeballs were measured in the two views of the CT image and three-dimensional volume of the face. Relative exophthalmometry was calculated by the difference in protrusion distance between the right and left sides. The eyeball protrusion was 4.9 and 12.5 mm in sagittal and transverse views, respectively. The protrusion distances were 2.9 mm in the three-dimensional volume of face. There were no significant differences between right and left sides in the degree of protrusion, and the difference was within 2 mm in more than 90% of the subjects. The results of the present study will provide reliable criteria for precise diagnosis and postoperative monitoring using CT imaging of diseases such as thyroid-associated ophthalmopathy and orbital tumors.

  8. [Anorectal Malignant Melanoma Is a Very Rare Disease and Has a Poor Prognosis].

    PubMed

    Yoshida, Yuta; Noura, Shingo; Matsumura, Tae; Hirota, Masaki; Shuto, Takashi; Muratsu, Arisa; Yasuyama, Harunobu; Takata, Akihiro; Koga, Chikato; Kameda, Chizu; Murakami, Masahiro; Kawabata, Ryohei; Shimizu, Junzo; Miwa, Hideaki; Hasegawa, Junichi

    2017-11-01

    We performed abdomino-perineal-resection(APR)on 2 cases of anorectal malignant melanoma. The first case was a 70- year-old woman suffering from bloody stool. Colonoscopy showed a black tumor in the rectum. Biopsy revealed a malignant melanoma. A CT scan showed multiple lung metastases and liver metastasis. She underwent surgery for the purpose of bleeding control, but died shortly thereafter because her liver and lung metastases had worsened. The second case was a 43- years-old man suffering from bloody stool. He had a black type 3 tumor in the rectum. A biopsy revealed malignant melanoma. A CT scan showed lateral lymph node swelling. He underwent APR with right side-lateral dissection. An established treatment for anorectal malignant melanoma has not been agreed upon and it is controversial. We experienced 2 cases that underwent surgery and we report them along with relevant information from the literature.

  9. Cephalometric assessment of human fetal head specimens.

    PubMed

    Radlanski, R J; Heikinheimo, K; Gruda, A

    2013-07-01

    Past investigations of prenatal craniofacial growth have largely relied on histological sections. Few studies have taken measurements on three-dimensional representations (3D reconstruction, 3D CT, postmortem) or varying depth levels (ultrasound), and we know of no craniofacial growth studies done on cleared-and-stained specimens of whole fetal heads. This study comprised 14 human fetal head specimens cleared and stained with alizarin red and alcian blue. They had been stored in glycerol and represented weeks 8-12 of gestation, with crown-rump lengths ranging from 23-145 mm. These specimens were cephalometrically analyzed in norma frontalis and norma lateralis, which notably included the opportunity for side-to-side comparison. As the cranial membrane bones progressively approached each other, the orbits, maxilla, and mandible gradually grew wider. Likewise, the sagittal dimensions of the maxilla and mandible increased continuously and synchronically. We noted side-to-side differences ranging from 2-5 mm. Another notable finding concerned the inclination of the maxilla relative to the cranial base, which increased more on the right than on the left side. This is the first investigation presenting side-to-side comparative measurements of human fetal head specimens. Such measurements are essential in the quest toward validating the findings of other imaging techniques such as CT or MRI and-most importantly-intrauterine sonography.

  10. Dual-modality, fluorescent, PLGA encapsulated bismuth nanoparticles for molecular and cellular fluorescence imaging and computed tomography

    NASA Astrophysics Data System (ADS)

    Swy, Eric R.; Schwartz-Duval, Aaron S.; Shuboni, Dorela D.; Latourette, Matthew T.; Mallet, Christiane L.; Parys, Maciej; Cormode, David P.; Shapiro, Erik M.

    2014-10-01

    Reports of molecular and cellular imaging using computed tomography (CT) are rapidly increasing. Many of these reports use gold nanoparticles. Bismuth has similar CT contrast properties to gold while being approximately 1000-fold less expensive. Herein we report the design, fabrication, characterization, and CT and fluorescence imaging properties of a novel, dual modality, fluorescent, polymer encapsulated bismuth nanoparticle construct for computed tomography and fluorescence imaging. We also report on cellular internalization and preliminary in vitro and in vivo toxicity effects of these constructs. 40 nm bismuth(0) nanocrystals were synthesized and encapsulated within 120 nm Poly(dl-lactic-co-glycolic acid) (PLGA) nanoparticles by oil-in-water emulsion methodologies. Coumarin-6 was co-encapsulated to impart fluorescence. High encapsulation efficiency was achieved ~70% bismuth w/w. Particles were shown to internalize within cells following incubation in culture. Bismuth nanocrystals and PLGA encapsulated bismuth nanoparticles exhibited >90% and >70% degradation, respectively, within 24 hours in acidic, lysosomal environment mimicking media and both remained nearly 100% stable in cytosolic/extracellular fluid mimicking media. μCT and clinical CT imaging was performed at multiple X-ray tube voltages to measure concentration dependent attenuation rates as well as to establish the ability to detect the nanoparticles in an ex vivo biological sample. Dual fluorescence and CT imaging is demonstrated as well. In vivo toxicity studies in rats revealed neither clinically apparent side effects nor major alterations in serum chemistry and hematology parameters. Calculations on minimal detection requirements for in vivo targeted imaging using these nanoparticles are presented. Indeed, our results indicate that these nanoparticles may serve as a platform for sensitive and specific targeted molecular CT and fluorescence imaging.Reports of molecular and cellular imaging using computed tomography (CT) are rapidly increasing. Many of these reports use gold nanoparticles. Bismuth has similar CT contrast properties to gold while being approximately 1000-fold less expensive. Herein we report the design, fabrication, characterization, and CT and fluorescence imaging properties of a novel, dual modality, fluorescent, polymer encapsulated bismuth nanoparticle construct for computed tomography and fluorescence imaging. We also report on cellular internalization and preliminary in vitro and in vivo toxicity effects of these constructs. 40 nm bismuth(0) nanocrystals were synthesized and encapsulated within 120 nm Poly(dl-lactic-co-glycolic acid) (PLGA) nanoparticles by oil-in-water emulsion methodologies. Coumarin-6 was co-encapsulated to impart fluorescence. High encapsulation efficiency was achieved ~70% bismuth w/w. Particles were shown to internalize within cells following incubation in culture. Bismuth nanocrystals and PLGA encapsulated bismuth nanoparticles exhibited >90% and >70% degradation, respectively, within 24 hours in acidic, lysosomal environment mimicking media and both remained nearly 100% stable in cytosolic/extracellular fluid mimicking media. μCT and clinical CT imaging was performed at multiple X-ray tube voltages to measure concentration dependent attenuation rates as well as to establish the ability to detect the nanoparticles in an ex vivo biological sample. Dual fluorescence and CT imaging is demonstrated as well. In vivo toxicity studies in rats revealed neither clinically apparent side effects nor major alterations in serum chemistry and hematology parameters. Calculations on minimal detection requirements for in vivo targeted imaging using these nanoparticles are presented. Indeed, our results indicate that these nanoparticles may serve as a platform for sensitive and specific targeted molecular CT and fluorescence imaging. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr01405g

  11. 16. OBLIQUE DETAIL VIEW OF STAMP BATTERIES AND APRONS, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. OBLIQUE DETAIL VIEW OF STAMP BATTERIES AND APRONS, LOOKING SOUTHWEST. EACH BATTERY CONTAINS FIVE STAMPS. TWO OF THE THREE BATTERIES ARE SIDE BY SIDE IN FOREGROUND, WHILE THE THIRD BATTERY IS SEPARATE (LOWER RIGHT). STAIRWAY UP IS AT LEFT SIDE. SEE CA-290-43 (CT) FOR IDENTICAL COLOR TRANSPARENCY. - Skidoo Mine, Park Route 38 (Skidoo Road), Death Valley Junction, Inyo County, CA

  12. 68Gallium-Arginine-Glycine-Aspartic Acid and 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Chondroblastic Osteosarcoma of the Skull.

    PubMed

    Orunmuyi, Akintunde; Modiselle, Moshe; Lengana, Thabo; Ebenhan, Thomas; Vorster, Mariza; Sathekge, Mike

    2017-09-01

    We report the case of a 32 year-old male with Chondroblastic Osteosarcoma of the skull, which was imaged with both 18 [F]fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) and 68 Gallium-arginine-glycine-aspartic acid ( 68 Ga-RGD) PET/CT. The 18 F-FDG PET/CT did not demonstrate the tumour, whereas the 68 Ga-RGD PET/CT clearly depicted a left-sided frontal tumour. 68 Ga-RGD PET/CT may be a clinically useful imaging modality for early detection of recurrent osteosarcoma, considering the limitations of 18 F-FDG PET in a setting of low glycolytic activity.

  13. Isolated tympanic plate fracture frequency and its relationship to mandibular trauma.

    PubMed

    Altay, Canan; Erdoğan, Nezahat; Batkı, Ozan; Eren, Erdem; Altay, Sedat; Karasu, Sebnem; Mete, Berna; Uluç, Engin

    2014-11-01

    This study evaluated the prevalence of isolated tympanic fractures and their correlation with mandibular fractures by using maxillofacial computed tomography (CT). We retrospectively evaluated the maxillofacial CT of 1590 patients who presented to our emergency department with maxillofacial trauma between December 2010 and December 2012. Maxillofacial CT was used as the criterion standard for evaluating patients with maxillofacial fractures. The CT images were evaluated by using an electronic picture archiving and communications system and interpreted independently by 2 radiologists. The maxillofacial CT images revealed mandibular fractures in 167 of the patients and isolated tympanic plate fractures in 35 of these 167 patients. Four patients (11%) had a bilateral tympanic plate fracture, and 31 patients (89%) had unilateral tympanic plate fracture. Of all the tympanic plate fractures, 19 (54%) were on the right side and 16 (46%) were on the left side (P > .05). In our results, a significant correlation between the presence of a right-sided tympanic plate fracture and fracture of the ipsilateral condylar process was found (P = .036). However, a statistically significant difference between the presence of a tympanic plate fracture and other mandible fractures, additional soft-tissue findings, or the number of fractures was not determined (P > .05). Sex had no impact on the presence of tympanic plate fracture (P > .05). The frequency of isolated tympanic plate fractures in maxillofacial trauma is low, but it is an important anatomic location. Condyle fractures are significantly associated with isolated tympanic plate fractures. The presence of these injuries should raise suspicion of a concomitant isolated tympanic plate fracture. Copyright © 2014 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  14. CT Characteristics of Pleural Plaques Related to Occupational or Environmental Asbestos Exposure from South Korean Asbestos Mines.

    PubMed

    Kim, Yookyung; Myong, Jun-Pyo; Lee, Jeong Kyong; Kim, Jeung Sook; Kim, Yoon Kyung; Jung, Soon-Hee

    2015-01-01

    This study evaluated the CT characteristics of pleural plaques in asbestos-exposed individuals and compared occupational versus environmental exposure groups. This study enrolled 181 subjects with occupational exposure and 98 with environmental exposure from chrysotile asbestos mines, who had pleural plaques confirmed by a chest CT. The CT scans were analyzed for morphological characteristics, the number and distribution of pleural plaques and combined pulmonary fibrosis. Furthermore, the CT findings were compared between the occupational and environmental exposure groups. Concerning the 279 subjects, the pleural plaques were single in 2.2% and unilateral in 3.6%, and showed variable widths (range, 1-20 mm; mean, 5.4 ± 2.7 mm) and lengths (5-310 mm; 72.6 ± 54.8 mm). The chest wall was the most commonly involved (98.6%), with an upper predominance on the ventral side (upper, 77.8% vs. lower, 55.9%, p < 0.001) and a lower predominance on the dorsal side (upper, 74.9% vs. lower, 91.8%, p = 0.02). Diaphragmatic involvement (78.1%) showed a right-side predominance (right, 73.8% vs. left, 55.6%, p < 0.001), whereas mediastinal plaques (42.7%) were more frequent on the left (right, 17.6% vs. left, 39.4%, p < 0.001). The extent and maximum length of plaques, and presence and severity of combined asbestosis, were significantly higher in the occupational exposure group (p < 0.05). Pleural plaques in asbestos-exposed individuals are variable in number and size; and show a predominant distribution in the upper ventral and lower dorsal chest walls, right diaphragm, and left mediastinum. Asbestos mine workers have a higher extent of plaques and pulmonary fibrosis versus environmentally exposed individuals.

  15. Volvulus of the ascending colon in a non-rotated midgut: Plain film and MDCT findings.

    PubMed

    Camera, Luigi; Calabrese, Milena; Mainenti, Pier Paolo; Masone, Stefania; Vecchio, Walter Del; Persico, Giovanni; Salvatore, Marco

    2012-10-28

    Colonic volvulus is a relatively uncommon cause of large bowel obstruction usually involving mobile, intra-peritoneal, colonic segments. Congenital or acquired anatomic variation may be associated with an increased risk of colonic volvulus which can occasionally involve retro-peritoneal segments. We report a case of 54-year-old female who presented to our Institution to perform a plain abdominal film series for acute onset of cramping abdominal pain. Both the upright and supine films showed signs of acute colonic obstruction which was thought to be due to an internal hernia of the transverse colon into the lesser sac. The patient was therefore submitted to a multi-detector contrast-enhanced computed tomography (CT). CT findings were initially thought to be consistent with the presumed diagnosis of internal hernia but further evaluation and coronal reformatting clearly depicted the presence of a colonic volvulus possibly resulting from a retro-gastric colon. At surgery, a volvulus of the ascending colon was found and a right hemi-colectomy had to be performed. However, a non rotated midgut with a right-sided duodeno-jejunal flexure and a left sided colon was also found at laparotomy and overlooked in the pre-operative CT. Retrospective evaluation of CT images was therefore performed and a number of CT signs of intestinal malrotation could be identified.

  16. 7. VIEW OF ESCAPE TRAINING TANK, LOOKING UP SOUTH SIDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW OF ESCAPE TRAINING TANK, LOOKING UP SOUTH SIDE FROM 50-FOOT PASSAGEWAY, SHOWING 25-FOOT BLISTER AT LEFT, 18-FOOT PASSAGEWAY AND PLATFORM AT RIGHT - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  17. Competitive Advantage of PET/MRI

    PubMed Central

    Jadvar, Hossein; Colletti, Patrick M.

    2013-01-01

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. PMID:23791129

  18. Competitive advantage of PET/MRI.

    PubMed

    Jadvar, Hossein; Colletti, Patrick M

    2014-01-01

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Imaging tissues for biomedical research using the high-resolution micro-tomography system nanotom® m

    NASA Astrophysics Data System (ADS)

    Deyhle, Hans; Schulz, Georg; Khimchenko, Anna; Bikis, Christos; Hieber, Simone E.; Jaquiery, Claude; Kunz, Christoph; Müller-Gerbl, Magdalena; Höchel, Sebastian; Saxer, Till; Stalder, Anja K.; Ilgenstein, Bernd; Beckmann, Felix; Thalmann, Peter; Buscema, Marzia; Rohr, Nadja; Holme, Margaret N.; Müller, Bert

    2016-10-01

    Micro computed tomography (mCT) is well established in virtually all fields of biomedical research, allowing for the non-destructive volumetric visualization of tissue morphology. A variety of specimens can be investigated, ranging from soft to hard tissue to engineered structures like scaffolds. Similarly, the size of the objects of interest ranges from a fraction of a millimeter to several tens of centimeters. While synchrotron radiation-based μCT still offers unrivaled data quality, the ever-improving technology of cathodic tube-based machines offers a valuable and more accessible alternative. The Biomaterials Science Center of the University of Basel operates a nanotomOR m (phoenix|x-ray, GE Sensing and Inspection Technologies GmbH, Wunstorf, Germany), with a 180 kV source and a minimal spot size of about 0.9 μm. Through the adjustable focus-specimen and focus-detector distances, the effective pixel size can be adjusted from below 500 nm to about 80 μm. On the high-resolution side, it is for example possible to visualize the tubular network in sub-millimeter thin dentin specimens. It is then possible to locally extract parameters such as tubule diameter, density, or alignment, giving information on cell movements during tooth formation. On the other side, with a horizontal shift of the 3,072 pixels x 2,400 pixels detector, specimens up to 35 cm in diameter can be scanned. It is possible, for example, to scan an entire human knee, albeit with inferior resolution. Lab source μCT machines are thus a powerful and flexible tool for the advancement of biomedical research, and a valuable and more accessible alternative to synchrotron radiation facilities.

  20. Initial experience of using an iron-containing fiducial marker for radiotherapy of prostate cancer: Advantages in the visualization of markers in Computed Tomography and Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Tanaka, Osamu; Iida, Takayoshi; Komeda, Hisao; Tamaki, Masayoshi; Seike, Kensaku; Kato, Daiki; Yokoyama, Takamasa; Hirose, Shigeki; Kawaguchi, Daisuke

    2016-12-01

    Visualization of markers is critical for imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI). However, the size of the marker varies according to the imaging technique. While a large-sized marker is more useful for visualization in MRI, it results in artifacts on CT and causes substantial pain on administration. In contrast, a small-sized marker reduces the artifacts on CT but hampers MRI detection. Herein, we report a new ironcontaining marker and compare its utility with that of non-iron-containing markers. Five patients underwent CT/MRI fusion-based intensity-modulated radiotherapy, and the markers were placed by urologists. A Gold Anchor™ (GA; diameter, 0.28 mm; length, 10 mm) was placed using a 22G needle on the right side of the prostate. A VISICOIL™ (VIS; diameter, 0.35 mm; length, 10 mm) was placed using a 19G needle on the left side. MRI was performed using T2*-weighted imaging. Three observers evaluated and scored the visual qualities of the acquired images. The mean score of visualization was almost identical between the GA and VIS in radiography and cone-beam CT (Novalis Tx). The artifacts in planning CT were slightly larger using the GA than using the VIS. The visualization of the marker on MRI using the GA was superior to that using the VIS. In conclusion, the visualization quality of radiography, conebeam CT, and planning CT was roughly equal between the GA and VIS. However, the GA was more strongly visualized than was the VIS on MRI due to iron containing.

  1. Encapsulated Unresolved Subdural Hematoma Mimicking Acute Epidural Hematoma: A Case Report

    PubMed Central

    Park, Sang-Soo; Kim, Hyo-Joon; Kwon, Chang-Young

    2014-01-01

    Encapsulated acute subdural hematoma (ASDH) has been uncommonly reported. To our knowledge, a few cases of lentiform ASDH have been reported. The mechanism of encapsulated ASDH has been studied but not completely clarified. Encapsulated lentiform ASDH on a computed tomography (CT) scan mimics acute epidural hematoma (AEDH). Misinterpretation of biconvex-shaped ASDH on CT scan as AEDH often occurs and is usually identified by neurosurgical intervention. We report a case of an 85-year-old man presenting with a 2-day history of mental deterioration and right-sided weakness. CT scan revealed a biconvex-shaped hyperdense mass mixed with various densities of blood along the left temporoparietal cerebral convexity, which was misinterpreted as AEDH preoperatively. Emergency craniectomy was performed, but no AEDH was found beneath the skull. In the subdural space, encapsulated ASDH was located. En block resection of encapsulated ASDH was done. Emergency craniectomy confirmed that the preoperatively diagnosed AEDH was an encapsulated ASDH postoperatively. Radiologic studies of AEDH-like SDH allow us to establish an easy differential diagnosis between AEDH and ASDH by distinct features. More histological studies will provide us information on the mechanism underlying encapsulated ASDH. PMID:27169052

  2. Advantages of anterior inferior alveolar nerve block with felypressin-propitocaine over conventional epinephrine-lidocaine: an efficacy and safety study

    PubMed Central

    Sunada, Katsuhisa

    2015-01-01

    Background Conventional anesthetic nerve block injections into the mandibular foramen risk causing nerve damage. This study aimed to compare the efficacy and safety of the anterior technique (AT) of inferior alveolar nerve block using felypressin-propitocaine with a conventional nerve block technique (CT) using epinephrine and lidocaine for anesthesia via the mandibular foramen. Methods Forty healthy university students with no recent dental work were recruited as subjects and assigned to two groups: right side CT or right side AT. Anesthesia was evaluated in terms of success rate, duration of action, and injection pain. These parameters were assessed at the first incisor, premolar, and molar, 60 min after injection. Chi-square and unpaired t-tests were used for statistical comparisons, with a P value of < 0.05 designating significance. Results The two nerve block techniques generated comparable success rates for the right mandible, with rates of 65% (CT) and 60% (AT) at both the first molar and premolar, and rates of 60% (CT) and 50% (AT) at the lateral incisor. The duration of anesthesia using the CT was 233 ± 37 min, which was approximately 40 min shorter than using the AT. This difference was statistically significant (P < 0.05). Injection pain using the AT was rated as milder compared with the CT. This difference was also statistically significant (P < 0.05). Conclusions The AT is no less successful than the CT for inducing anesthesia, and has the added benefits of a significantly longer duration of action and significantly less pain. PMID:28879260

  3. Advantages of anterior inferior alveolar nerve block with felypressin-propitocaine over conventional epinephrine-lidocaine: an efficacy and safety study.

    PubMed

    Shinzaki, Hazuki; Sunada, Katsuhisa

    2015-06-01

    Conventional anesthetic nerve block injections into the mandibular foramen risk causing nerve damage. This study aimed to compare the efficacy and safety of the anterior technique (AT) of inferior alveolar nerve block using felypressin-propitocaine with a conventional nerve block technique (CT) using epinephrine and lidocaine for anesthesia via the mandibular foramen. Forty healthy university students with no recent dental work were recruited as subjects and assigned to two groups: right side CT or right side AT. Anesthesia was evaluated in terms of success rate, duration of action, and injection pain. These parameters were assessed at the first incisor, premolar, and molar, 60 min after injection. Chi-square and unpaired t-tests were used for statistical comparisons, with a P value of < 0.05 designating significance. The two nerve block techniques generated comparable success rates for the right mandible, with rates of 65% (CT) and 60% (AT) at both the first molar and premolar, and rates of 60% (CT) and 50% (AT) at the lateral incisor. The duration of anesthesia using the CT was 233 ± 37 min, which was approximately 40 min shorter than using the AT. This difference was statistically significant (P < 0.05). Injection pain using the AT was rated as milder compared with the CT. This difference was also statistically significant (P < 0.05). The AT is no less successful than the CT for inducing anesthesia, and has the added benefits of a significantly longer duration of action and significantly less pain.

  4. Evaluation of the optimal visceral branch configuration in open thoracoabdominal aortic repair by computed tomography.

    PubMed

    Kamohara, Keiji; Furukawa, Kojiro; Itoh, Manabu; Morokuma, Hiroyuki; Tanaka, Hideya; Hayashi, Nagi; Morita, Shigeki

    2015-01-01

    In thoracoabdominal aneurysm (TAAA) repair, our technical modification of visceral reconstruction using longer cut pre-sewn side branches has provided good surgical outcomes. Here, we assessed the long-term durability and patency of revascularized branches using computed tomography (CT) to confirm the validity of our approach. Early and late CT evaluations were performed in 11 TAAA patients (males: 5; mean age: 60.6 years) using the Coselli graft to evaluate the position of main graft and the diverging pattern and patency of side branches. Seven of 11 were sutured in an extra-anatomical fashion using longer cut side branches. In Anatomical (n = 4) and Extra-anatomical (n = 7) groups, the early patency of side branches was not significantly different. Although the late patency of right renal artery (RA) was 100% in both groups, the one of left RA was 60% in Extra-anatomical, while 100% in Anatomical. Furthermore, the main graft in Extra-anatomical was significantly posterior and leftward to the spine with left RA side branch diverging at an acute angle. When a pre-sewn branched graft designed for TAAA is used, the graft should be sutured in a fashion similar to normal patient anatomy to minimize the possibility of kinking of RA side branch for the patency.

  5. An evaluation of unisensory and multisensory adaptive flight-path navigation displays

    NASA Astrophysics Data System (ADS)

    Moroney, Brian W.

    1999-11-01

    The present study assessed the use of unimodal (auditory or visual) and multimodal (audio-visual) adaptive interfaces to aid military pilots in the performance of a precision-navigation flight task when they were confronted with additional information-processing loads. A standard navigation interface was supplemented by adaptive interfaces consisting of either a head-up display based flight director, a 3D virtual audio interface, or a combination of the two. The adaptive interfaces provided information about how to return to the pathway when off course. Using an advanced flight simulator, pilots attempted two navigation scenarios: (A) maintain proper course under normal flight conditions and (B) return to course after their aircraft's position has been perturbed. Pilots flew in the presence or absence of an additional information-processing task presented in either the visual or auditory modality. The additional information-processing tasks were equated in terms of perceived mental workload as indexed by the NASA-TLX. Twelve experienced military pilots (11 men and 1 woman), naive to the purpose of the experiment, participated in the study. They were recruited from Wright-Patterson Air Force Base and had a mean of 2812 hrs. of flight experience. Four navigational interface configurations, the standard visual navigation interface alone (SV), SV plus adaptive visual, SV plus adaptive auditory, and SV plus adaptive visual-auditory composite were combined factorially with three concurrent tasks (CT), the no CT, the visual CT, and the auditory CT, a completely repeated measures design. The adaptive navigation displays were activated whenever the aircraft was more than 450 ft off course. In the normal flight scenario, the adaptive interfaces did not bolster navigation performance in comparison to the standard interface. It is conceivable that the pilots performed quite adequately using the familiar generic interface under normal flight conditions and hence showed no added benefit of the adaptive interfaces. In the return-to-course scenario, the relative advantages of the three adaptive interfaces were dependent upon the nature of the CT in a complex way. In the absence of a CT, recovery heading performance was superior with the adaptive visual and adaptive composite interfaces compared to the adaptive auditory interface. In the context of a visual CT, recovery when using the adaptive composite interface was superior to that when using the adaptive visual interface. Post-experimental inquiry indicated that when faced with a visual CT, the pilots used the auditory component of the multimodal guidance display to detect gross heading errors and the visual component to make more fine-grained heading adjustments. In the context of the auditory CT, navigation performance using the adaptive visual interface tended to be superior to that when using the adaptive auditory interface. Neither CT performance nor NASA-TLX workload level was influenced differentially by the interface configurations. Thus, the potential benefits associated with the proposed interfaces appear to be unaccompanied by negative side effects involving CT interference and workload. The adaptive interface configurations were altered without any direct input from the pilot. Thus, it was feared that pilots might reject the activation of interfaces independent of their control. However, pilots' debriefing comments about the efficacy of the adaptive interface approach were very positive. (Abstract shortened by UMI.)

  6. Condyle fossa relationship associated with functional posterior crossbite, before and after rapid maxillary expansion.

    PubMed

    Leonardi, Rosalia; Caltabiano, Mario; Cavallini, Costanza; Sicurezza, Edoardo; Barbato, Ersilia; Spampinato, Concetto; Giordano, Daniela

    2012-11-01

    To investigate condylar symmetry and condyle fossa relationships in subjects with functional posterior crossbite comparing findings before and after rapid maxillary expansion (RME) treatment through low-dose computed tomography (CT). Twenty-six patients (14 girls and 12 boys, mean age 9.6 ± 1.4 years) with functional posterior crossbite (FPXB) diagnosis underwent rapid palatal expansion with a Hyrax appliance. Patients' temporomandibular joints (TMJ) underwent multislice CT scans before rapid palatal expansion (T0) and after (T1). Joint spaces were compared with those of a control sample of 13 subjects (7 girls and 5 boys, mean age 11 ± 0.6 years). Anterior space (AS), superior space (SS), and posterior space (PS) joint space measurements at T0 between the FPXB side and contralateral side demonstrated no statistically significant differences. After RME treatment (T1), all three joint spaces increased on both the FPXB side and the non-crossbite side. However, differences were statistically significant only for the SS when comparing the two sides at T1. SS increased more than AS and PS in the non-crossbite condyle (0.28 mm) and FPXB condyle (0.37 mm), and PS increased only on the FPXB side (0.34 mm). There were no statistically significant differences in condyle position within the glenoid fossa between the FPXB and non-crossbite side before treatment. Increases in joint spaces were observed after treatment with RME on both sides. These changes were, however, of small amounts.

  7. Three-dimensional quantification of orthodontic root resorption with time-lapsed imaging of micro-computed tomography in a rodent model.

    PubMed

    Yang, Chongshi; Zhang, Yuanyuan; Zhang, Yan; Fan, Yubo; Deng, Feng

    2015-01-01

    Despite various X-ray approaches have been widely used to monitor root resorption after orthodontic treatment, a non-invasive and accurate method is highly desirable for long-term follow up. The aim of this study was to build a non-invasive method to quantify longitudinal orthodontic root resorption with time-lapsed images of micro-computed tomography (micro-CT) in a rodent model. Twenty male Sprague Dawley (SD) rats (aged 6-8 weeks, weighing 180-220 g) were used in this study. A 25 g orthodontic force generated by nickel-titanium coil spring was applied to the right maxillary first molar for each rat, while contralateral first molar was severed as a control. Micro-CT scan was performed at day 0 (before orthodontic load) and days 3, 7, 14, and 28 after orthodontic load. Resorption of mesial root of maxillary first molars at bilateral sides was calculated from micro-CT images with registration algorithm via reconstruction, superimposition and partition operations. Obvious resorption of mesial root of maxillary first molar can be detected at day 14 and day 28 at orthodontic side. Most of the resorption occurred in the apical region at distal side and cervical region at mesiolingual side. Desirable development of molar root of rats was identified from day 0 to day 28 at control side. The development of root concentrated on apical region. This non-invasive 3D quantification method with registration algorithm can be used in longitudinal study of root resorption. Obvious root resorption in rat molar can be observed three-dimensionally at day 14 and day 28 after orthodontic load. This indicates that registration algorithm combined with time-lapsed images provides clinic potential application in detection and quantification of root contour.

  8. Catechin-loaded Eudragit microparticles for the management of diabetes: formulation, characterization and in vivo evaluation of antidiabetic efficacy.

    PubMed

    Meena, Kedar Prasad; Vijayakumar, Mahalingam Rajamanickam; Dwibedy, Priti S

    2017-06-01

    Catechin (CT) is natural molecule proved for antidiabetic activity. Clinical application of CT is highly restricted because of its low bioavailability and ineffectiveness in in vivo conditions. Therefore, the main objective of the present investigation was to formulate CT-loaded Eudragit RS 100 microparticles and evaluated for its potential against diabetes. CT microparticles showing highest entrapment efficiency of 92.3 ± 6.5% and higher percentage yield of 63.46 ± 4.3% was selected as optimised formulation. CT microparticles treated rats showed significantly lower blood glucose, cholesterol, LDL, free fatty acid and triglyceride concentrations in comparison to pristine CT-treated rats. The glucose and lipid profiles of microparticle formulation were akin to normal rats. Moreover, CT microparticles did not produce obesity even after 60 days which is a comment side effect of antidiabetic drugs. These results indicate that the CT microparticles can be applied as potential and safe carrier for the treatment of diabetes.

  9. Malignant Jugular Paraganglioma: Unusual Presentation on 68Ga DOTANOC PET/CT.

    PubMed

    Jain, Tarun Kumar; Basher, Rajender Kumar; Shukla, Jaya; Mittal, Bhagwant Rai; Panda, Naresh K

    2016-02-01

    Metastatic jugular paraganglioma are rare tumors and account for less than 1% of the cases of head and neck tumors. We report a 40-year-old woman of jugular paraganglioma, presenting with right-sided neck swelling, hearing loss, and pulsatile tinnitus. Contrast-enhanced CT temporal bone revealed a mass in the right jugular foramina and extending inferiorly to internal jugular vein. Ga DOTANOC PET/CT was performed, which revealed somatostatin receptor expressing lesion in the right internal jugular vein and extension into sigmoid sinus and additional metastatic focus in the sacrum.

  10. MHD Instabilities and Toroidal Field Effects on Plasma Column Behavior in Tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khorshid, Pejman; Plasma Physics Research Center, Islamic Azad University, 14665-678, Tehran; Wang, L.

    2006-12-04

    In the edge plasma of the CT-6B and IRAN-T1 tokamaks the shape of plasma column based on MHD behavior has been studied. The bulk of plasma behavior during plasma column rotation as non-rigid body plasma has been investigated. We found that mode number and rotation frequency of plasma column are different in angle position, so that the mode number detected from Mirnov coils array located in poloidal angle on the inner side of chamber is more than outer side which it can be because of toroidal magnetic field effects. The results of IR-T1 and CT-6B tokamaks compared with each other,more » so that in the CT-6B because of its coils number must be less, but because of its Iron core the effect of toroidal magnetic field became more effective with respect to IR-T1. In addition, it is shown that the plasma column behaves as non-Rigid body plasma so that the poloidal rotation velocity variation in CT-6B is more than IR-T1. A relative correction for island rotation frequency has been suggested in connection with IRAN-T1 and CT-6B tokamak results, which can be considered for optical measurement purposes and also for future advanced tokamak control design.« less

  11. Simultaneous CT and SPECT tomography using CZT detectors

    DOEpatents

    Paulus, Michael J.; Sari-Sarraf, Hamed; Simpson, Michael L.; Britton, Jr., Charles L.

    2002-01-01

    A method for simultaneous transmission x-ray computed tomography (CT) and single photon emission tomography (SPECT) comprises the steps of: injecting a subject with a tracer compound tagged with a .gamma.-ray emitting nuclide; directing an x-ray source toward the subject; rotating the x-ray source around the subject; emitting x-rays during the rotating step; rotating a cadmium zinc telluride (CZT) two-sided detector on an opposite side of the subject from the source; simultaneously detecting the position and energy of each pulsed x-ray and each emitted .gamma.-ray captured by the CZT detector; recording data for each position and each energy of each the captured x-ray and .gamma.-ray; and, creating CT and SPECT images from the recorded data. The transmitted energy levels of the x-rays lower are biased lower than energy levels of the .gamma.-rays. The x-ray source is operated in a continuous mode. The method can be implemented at ambient temperatures.

  12. Influence of CT-based depth correction of renal scintigraphy in evaluation of living kidney donors on side selection and postoperative renal function: is it necessary to know the relative renal function?

    PubMed

    Weinberger, Sarah; Klarholz-Pevere, Carola; Liefeldt, Lutz; Baeder, Michael; Steckhan, Nico; Friedersdorff, Frank

    2018-03-22

    To analyse the influence of CT-based depth correction in the assessment of split renal function in potential living kidney donors. In 116 consecutive living kidney donors preoperative split renal function was assessed using the CT-based depth correction. Influence on donor side selection and postoperative renal function of the living kidney donors were analyzed. Linear regression analysis was performed to identify predictors of postoperative renal function. A left versus right kidney depth variation of more than 1 cm was found in 40/114 donors (35%). 11 patients (10%) had a difference of more than 5% in relative renal function after depth correction. Kidney depth variation and changes in relative renal function after depth correction would have had influence on side selection in 30 of 114 living kidney donors. CT depth correction did not improve the predictability of postoperative renal function of the living kidney donor. In general, it was not possible to predict the postoperative renal function from preoperative total and relative renal function. In multivariate linear regression analysis, age and BMI were identified as most important predictors for postoperative renal function of the living kidney donors. Our results clearly indicate that concerning the postoperative renal function of living kidney donors, the relative renal function of the donated kidney seems to be less important than other factors. A multimodal assessment with consideration of all available results including kidney size, location of the kidney and split renal function remains necessary.

  13. Comparison of onboard low-field magnetic resonance imaging versus onboard computed tomography for anatomy visualization in radiotherapy.

    PubMed

    Noel, Camille E; Parikh, Parag J; Spencer, Christopher R; Green, Olga L; Hu, Yanle; Mutic, Sasa; Olsen, Jeffrey R

    2015-01-01

    Onboard magnetic resonance imaging (OB-MRI) for daily localization and adaptive radiotherapy has been under development by several groups. However, no clinical studies have evaluated whether OB-MRI improves visualization of the target and organs at risk (OARs) compared to standard onboard computed tomography (OB-CT). This study compared visualization of patient anatomy on images acquired on the MRI-(60)Co ViewRay system to those acquired with OB-CT. Fourteen patients enrolled on a protocol approved by the Institutional Review Board (IRB) and undergoing image-guided radiotherapy for cancer in the thorax (n = 2), pelvis (n = 6), abdomen (n = 3) or head and neck (n = 3) were imaged with OB-MRI and OB-CT. For each of the 14 patients, the OB-MRI and OB-CT datasets were displayed side-by-side and independently reviewed by three radiation oncologists. Each physician was asked to evaluate which dataset offered better visualization of the target and OARs. A quantitative contouring study was performed on two abdominal patients to assess if OB-MRI could offer improved inter-observer segmentation agreement for adaptive planning. In total 221 OARs and 10 targets were compared for visualization on OB-MRI and OB-CT by each of the three physicians. The majority of physicians (two or more) evaluated visualization on MRI as better for 71% of structures, worse for 10% of structures, and equivalent for 14% of structures. 5% of structures were not visible on either. Physicians agreed unanimously for 74% and in majority for > 99% of structures. Targets were better visualized on MRI in 4/10 cases, and never on OB-CT. Low-field MR provides better anatomic visualization of many radiotherapy targets and most OARs as compared to OB-CT. Further studies with OB-MRI should be pursued.

  14. Correlation between age and the parameters of medial epiphysis and metaphysis of the clavicle using CT volume rendering images.

    PubMed

    Hua, Wei; Guang-you, Zhu; Lei, Wan; Chong-liang, Ying; Ya-hui, Wang

    2014-11-01

    The aim of this study was to evaluate the correlation between age and the parameters of medial epiphysis of clavicle based on CT volume rendering (VR) images. The CT images of the medial clavicle from 795 teenagers (387 male and 408 female) between 15 and 25 years were collected in East and South China. VR images were recombined from 0.60 mm thickness slice CT images. The ratio of epiphyseal diameter/metaphyseal diameter and the ratio of epiphyseal area/metaphyseal area of two sides of medial clavicle were measured and calculated by three different examiners, the quantitative data consistency was checked by intraclass correlation coefficients (ICC). The diameter ratio of left and right side are depicted as X1 and X3, and the area ratio of left and right side as X2 and X4. Descriptive statistic analysis of the data was performed and several mathematical models were established using least square. CT images from additional 60 teenagers (30 male and 30 female) were used to verify the accuracy of the established mathematical models. ICC indicated that the measurement of epiphyseal diameter, metaphyseal diameter, the ratio of epiphyseal diameter/metaphyseal diameter, epiphyseal area, metaphyseal area and the ratio of epiphyseal area/metaphyseal area of medial clavicle in the left and right side of the three examiners was approaching 1. The 95% reference range for the mean of every examination of both genders gradually increased with age. Females' data indicated by medial epiphysis of the clavicle development were earlier than male's, especially from 15 to 21 years. The difference of medial epiphysis of the clavicle development in gender becomes smaller after 21 years. The highest accuracy of the mathematical models made clear that male's accuracy was 73.5% (±1.0 year) and 85.3% (±1.5 year), and female's was 68.6% (±1.0 year) and 82.2% (±1.5 year) respectively. The methods of data collection and analysis were reliable and feasible. Combined the high accuracy of these established mathematical models, it is applicable to use the ratio of epiphyseal diameter/metaphyseal diameter and the ratio of epiphyseal area/metaphyseal area of left and right side of medial clavicle to estimate the teenager's age. Bearing this in mind, further studies are needed to evaluate slice thickness as the most critical parameter. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. The risk of translaminar screw fixation to the transverse foramen of the lower cervical spine: a computed tomography study.

    PubMed

    Kong, Ganggang; Ji, Wei; Huang, Zucheng; Liu, Junhao; Chen, Jianting; Zhu, Qingan

    2017-04-21

    Translaminar screw fixation (TSF) of the axis is considered as an efficient, safe and simple surgical procedure, however the study of the potential risk of TSF to the transverse foramen in lower cervical spine is lacked. Head-neck CT images of 60 patients were included in this study. Maximum screw length, laminar thickness, the screw angle and the laminar height were measured. The feasibility of 3.5-mm diameter screw fixation and the potential risk of transverse foramen injury was analyzed. The TSF was safe at C3 and C4, but risky to the transverse foraman at a rate of 8.7% at C5 (0% on the left side and 20% on the right side), 33.3% at C6 (24.4% on the left side and 42.9% on the right side). C7 had the highest 77.8% rate (65.5% on the left side and 89.8% on the right side). The safe screw length was 27.7 mm at C3, 27.4 mm at C4, 28.0 mm at C5, 25.6 mm at C6 and 25.5 mm at C7, respectively. The present study showed that translaminar screw could place the transverse foramen of C5-C7 at risk. Preoperative CT scanning was necessary for safe screw placement.

  16. 1. PERSPECTIVE VIEW FROM NORTHWEST OF NORTH SIDE. LOW BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. PERSPECTIVE VIEW FROM NORTHWEST OF NORTH SIDE. LOW BUILDING IN CENTER IS A SIGNAL POWER GENERATING STATION (C. 1986). LOW TOWER STRUCTURE ON THE LEFT IS ANCHOR BRIDGE NUMBER 310, LOCATION OF POWER FEED TO THE CATENARY SYSTEM. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  17. Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy.

    PubMed

    Hasegawa, Hiroaki; Sato, Masanori; Tanaka, Hiroshi

    2015-01-01

    The purpose of this study was to evaluate scatter radiation dose to the subject surface during X-ray computed tomography (CT) fluoroscopy using the integrated dose ratio (IDR) of an X-ray dose profile derived from an optically stimulated luminescent (OSL) dosimeter. We aimed to obtain quantitative evidence supporting the radiation protection methods used during previous CT fluoroscopy. A multislice CT scanner was used to perform this study. OSL dosimeters were placed on the top and the lateral side of the chest phantom so that the longitudinal direction of dosimeters was parallel to the orthogonal axis-to-slice plane for measurement of dose profiles in CT fluoroscopy. Measurement of fluoroscopic conditions was performed at 120 kVp and 80 kVp. Scatter radiation dose was evaluated by calculating the integrated dose determined by OSL dosimetry. The overall percent difference of the integrated doses between OSL dosimeters and ionization chamber was 5.92%. The ratio of the integrated dose of a 100-mm length area to its tails (-50 to -6 mm, 50 to 6 mm) was the lowest on the lateral side at 80 kVp and the highest on the top at 120 kVp. The IDRs for different measurement positions were larger at 120 kVp than at 80 kVp. Similarly, the IDRs for the tube voltage between the primary X-ray beam and scatter radiation was larger on the lateral side than on the top of the phantom. IDR evaluation suggested that the scatter radiation dose has a high dependence on the position and a low dependence on tube voltage relative to the primary X-ray beam for constant dose rate fluoroscopic conditions. These results provided quantitative evidence supporting the radiation protection methods used during CT fluoroscopy in previous studies.

  18. Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy

    PubMed Central

    Hasegawa, Hiroaki; Sato, Masanori; Tanaka, Hiroshi

    2015-01-01

    The purpose of this study was to evaluate scatter radiation dose to the subject surface during X-ray computed tomography (CT) fluoroscopy using the integrated dose ratio (IDR) of an X-ray dose profile derived from an optically stimulated luminescent (OSL) dosimeter. We aimed to obtain quantitative evidence supporting the radiation protection methods used during previous CT fluoroscopy. A multislice CT scanner was used to perform this study. OSL dosimeters were placed on the top and the lateral side of the chest phantom so that the longitudinal direction of dosimeters was parallel to the orthogonal axis-to-slice plane for measurement of dose profiles in CT fluoroscopy. Measurement of fluoroscopic conditions was performed at 120 kVp and 80 kVp. Scatter radiation dose was evaluated by calculating the integrated dose determined by OSL dosimetry. The overall percent difference of the integrated doses between OSL dosimeters and ionization chamber was 5.92%. The ratio of the integrated dose of a 100-mm length area to its tails (−50 to −6 mm, 50 to 6 mm) was the lowest on the lateral side at 80 kVp and the highest on the top at 120 kVp. The IDRs for different measurement positions were larger at 120 kVp than at 80 kVp. Similarly, the IDRs for the tube voltage between the primary X-ray beam and scatter radiation was larger on the lateral side than on the top of the phantom. IDR evaluation suggested that the scatter radiation dose has a high dependence on the position and a low dependence on tube voltage relative to the primary X-ray beam for constant dose rate fluoroscopic conditions. These results provided quantitative evidence supporting the radiation protection methods used during CT fluoroscopy in previous studies. PMID:26151914

  19. The role of physician characteristics in clinical trial acceptance: testing pathways of influence.

    PubMed

    Curbow, Barbara; Fogarty, Linda A; McDonnell, Karen A; Chill, Julia; Scott, Lisa Benz

    2006-03-01

    Eight videotaped vignettes were developed that assessed the effects of three physician-related experimental variables (in a 2 x 2 x 2 factorial design) on clinical trial (CT) knowledge, video knowledge, information processing, CT beliefs, affective evaluations (attitudes), and CT acceptance. It was hypothesized that the physician variables (community versus academic-based affiliation, enthusiastic versus neutral presentation of the trial, and new versus previous relationship with the patient) would serve as communication cues that would interrupt message processing, leading to lower knowledge gain but more positive beliefs, attitudes, and CT acceptance. A total of 262 women (161 survivors and 101 controls) participated in the study. The manipulated variables primarily influenced the intermediary variables of post-test CT beliefs and satisfaction with information rather than knowledge or information processing. Multiple regression results indicated that CT acceptance was associated with positive post-CT beliefs, a lower level of information processing, satisfaction with information, and control status. Based on these results, CT acceptance does not appear to be based on a rational decision-making model; this has implications for both the ethics of informed consent and research conceptual models.

  20. Functional magnetic resonance imaging to determine hemispheric language dominance prior to carotid endarterectomy.

    PubMed

    Smits, M; Wieberdink, R G; Bakker, S L M; Dippel, D W J

    2011-04-01

    We describe a left-handed patient with transient aphasia and bilateral carotid stenosis. Computed tomography (CT) arteriography showed a 90% stenosis of the right and 30% stenosis of the left internal carotid artery. Head CT and magnetic resonance imaging (MRI) of the brain showed no recent ischemic changes. As only the symptomatic side would require surgical intervention, and because hemispheric dominance for language in left-handed patients may be either left or right sided, a preoperative assessment of hemispheric dominance was required. We used functional MRI to determine hemispheric dominance for language and hence to establish the indication for carotid endarterectomy surgery. Functional MRI demonstrated right hemispheric dominance for language and right-sided carotid endarterectomy was performed. We propose that the clinical use of functional MRI as a noninvasive imaging technique for the assessment of hemispheric language dominance may be extended to the assessment of hemispheric language dominance prior to carotid endarterectomy. Copyright © 2010 by the American Society of Neuroimaging.

  1. A Rare Case of Malignant Melanoma of the Mandible: 
CT and MRI Findings.

    PubMed

    Ogura, Ichiro; Sasaki, Yoshihiko; Kameta, Ayako; Sue, Mikiko; Oda, Takaaki

    Malignant melanoma of the mandibular gingiva is extremely rare. It is a malignant tumour of melanocytes or their precursor cells, and often misinterpreted as a benign pigmented process. A few reports have described computed tomography (CT) and magnetic resonance imaging (MRI) findings of malignant melanoma in the oral cavity. We report a rare case of malignant melanoma of the mandible and the related CT and MRI findings. Soft tissue algorithm contrast-enhanced CT showed an expansile mass and irregular destruction of alveolar bone in the right side of the mandibular molar area. MR images showed an enhancing mass and the tumour had a low to intermediate signal intensity and a high-signal intensity. Soft tissue algorithm contrast-enhanced CT and MR images showed lymphadenopathy involving the submandibular lymph nodes. Histopathological examination confirmed the diagnosis of malignant melanoma.

  2. A disappearing left-sided neck mass.

    PubMed

    Lutwak, Nancy; Dill, Curt

    2012-07-04

    The patient was a 48-year-old man who presented to the emergency department with complaints of a left-sided painful neck mass, which changed in size relative to ingestion of meals. He denied voice change, fever, chills, weight loss, dysphagia and hoarseness. Physical examination was unremarkable. CT scan demonstrated a 3.9 mm calculus of the submandibular gland duct. Therapeutic sialendocopy was successfully performed.

  3. Helical cone beam CT with an asymmetrical detector.

    PubMed

    Zamyatin, Alexander A; Taguchi, Katsuyuki; Silver, Michael D

    2005-10-01

    If a multislice or other area detector is shifted to one side to cover a larger field of view, then the data are truncated on one side. We propose a method to restore the missing data in helical cone-beam acquisitions that uses measured data on the longer side of the asymmetric detector array. The method is based on the idea of complementary rays, which is well known in fan beam geometry; in this paper we extend this concept to the cone-beam case. Different cases of complementary data coverage and dependence on the helical pitch are considered. The proposed method is used in our prototype 16-row CT scanner with an asymmetric detector and a 700 mm field of view. For evaluation we used scanned body phantom data and computer-simulated data. To simulate asymmetric truncation, the full, symmetric datasets were truncated by dropping either 22.5% or 45% from one side of the detector. Reconstructed images from the prototype scanner with the asymmetrical detector show excellent image quality in the extended field of view. The proposed method allows flexible helical pitch selection and can be used with overscan, short-scan, and super-short-scan reconstructions.

  4. CT of the "Tegernsee Giant": juvenile gigantism and polyostotic fibrous dysplasia.

    PubMed

    Vogl, T J; Nerlich, A; Dresel, S H; Bergman, C

    1994-01-01

    We report the radiological findings in the unusual case of the Bavarian "Tegernsee Giant." With conventional radiography, CT, and histologic examination, we succeeded in diagnosing two disorders: The Tegernsee Giant suffered from (a) juvenile gigantism caused by a growth hormone-secreting tumor of the pituitary gland and (b) a polyostotic form of fibrous dysplasia of the skull and multiple bones particularly on the left side of the body.

  5. Abdomen after a Puestow procedure: postoperative CT appearance, complications, and potential pitfalls.

    PubMed

    Freed, K S; Paulson, E K; Frederick, M G; Keogan, M T; Pappas, T N

    1997-06-01

    To evaluate the postoperative computed tomographic (CT) appearance, complications, and potential pitfalls after a Puestow procedure (lateral side-to-side pancreaticojejunostomy). Forty CT examinations were performed after the Puestow procedure in 20 patients. Images were retrospectively reviewed by three radiologists. The pancreaticojejunal anastomosis was identified at 30 examinations and was immediately anterior to the pancreatic body or tail. The anastomosis contained fluid or gas on 11 scans and oral contrast material on four scans. On 15 scans, the anastomosis appeared as collapsed bowel without gas, fluid, or oral contrast material. The Roux-en-Y loop was identified on 28 (70%) scans and contained fluid or gas on 16 scans and oral contrast material on six scans. The Roux-en-Y loop appeared as collapsed bowel on six scans. When the anastomosis or Roux-en-Y loop contained fluid and gas, the appearance mimicked that of a pancreatic or parapancreatic abscess. Peripancreatic stranding was present on 28 scans and was due to either ongoing pancreatitis or postoperative change. Complications included 15 transient fluid collections, three abscesses, four pseudocysts, one hematoma, and one small-bowel and Roux-en-Y obstruction. Knowledge of the anatomy after a Puestow procedure is essential for accurate interpretation of CT scans.

  6. Abdominal rectus muscle atrophy and midline shift after colostomy creation.

    PubMed

    Timmermans, Lucas; Deerenberg, Eva B; van Dijk, Sven M; Lamme, Bas; Koning, Anton H; Kleinrensink, Gert-Jan; Jeekel, Johannes; Lange, Johan F

    2014-04-01

    Incisional hernia (IH) can be attributed to multiple factors. The presence of a parastomal hernia has shown to be a risk factor for IH after midline laparotomy. Our hypothesis is that this increased risk of IH may be caused by changes in biomechanical forces, such as midline shift to the contralateral side of the colostomy owing to decreased restraining forces at the site of the colostomy, and left abdominal rectus muscle (ARM) atrophy owing to intercostal nerve damage. Patients were selected if they underwent end-colostomy via open operation between 2004 and 2011. Patients were eligible if computed tomography (CT) had been performed postoperatively. If available, preoperative CTs were collected for case-control analyses. Midline shift was measured using V-scope application in the I-space, a CAVE-like virtual reality system. For the ARM atrophy hypothesis, measurements of ARM were performed at the level of colostomy, and 3 and 8 cm cranial and caudal of the colostomy. Postoperative CT were available for 77 patients; of these patients, 30 also had a preoperative CT. Median follow-up was 19 months. A mean shift to the right side was identified after preoperative and postoperative comparison; from -1.3 ± 4.6 to 2.1 ± 9.3 (P = .043). Furthermore, during rectus muscle measurements, a thinner left ARM was observed below the level of colostomy. Creation of a colostomy alters the abdominal wall. Atrophy of the left ARM was seen caudal to the level of the colostomy, and a midline shift to the right side was evident on CT. These changes may explain the increased rate of IH after colostomy creation. Copyright © 2014 Mosby, Inc. All rights reserved.

  7. Use of ECG-gated computed tomography, echocardiography and selective angiography in five dogs with pulmonic stenosis and one dog with pulmonic stenosis and aberrant coronary arteries.

    PubMed

    Laborda-Vidal, P; Pedro, B; Baker, M; Gelzer, A R; Dukes-McEwan, J; Maddox, T W

    2016-12-01

    Pulmonic stenosis (PS) is the most common congenital cardiac disease in dogs. Boxers and English bulldogs are among the most commonly affected breeds and also commonly associated with an aberrant coronary artery (CA). If an aberrant CA is suspected and balloon valvuloplasty indicated, an intra-operative angiography is recommended prior to the procedure. ECG-gated computed tomography (CT) can be used to screen for CA anomalies in a quick and minimally-invasive way (preventing side effects associated with selective catheter angiography) and allowing early planning of the procedure. The aim of this case series was to report CT findings associated with PS diagnosed by echocardiography. Our database was retrospectively searched for cases of dogs with PS diagnosed by echocardiography, where an ECG-gated CT was performed. A total of six cases were retrieved: all were diagnosed with severe PS. Four dogs had concurrent congenital defects: two dogs had a patent ductus arteriosus, one dog had a ventricular septal defect and an overriding aorta, one dog had an aberrant CA. Detailed CT findings of all cases were reported, including one case of a patent ductus arteriosus and an overriding aorta not identified by transthoracic echocardiography. In addition, an abnormal single left coronary ostium, with a pre-pulmonic right CA was described. In conclusion, despite echocardiography remaining the gold standard for diagnosis and assessment of PS, ECG-gated-CT angiography is a complementary diagnostic method that may provide additional relevant information, shorten surgery/anaesthesia time and reduce the amount of radiation to which the clinician is subjected. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters.

    PubMed

    Kalra, Mannudeep K; Maher, Michael M; Blake, Michael A; Lucey, Brian C; Karau, Kelly; Toth, Thomas L; Avinash, Gopal; Halpern, Elkan F; Saini, Sanjay

    2004-09-01

    To assess the effect of noise reduction filters on detection and characterization of lesions on low-radiation-dose abdominal computed tomographic (CT) images. Low-dose CT images of abdominal lesions in 19 consecutive patients (11 women, eight men; age range, 32-78 years) were obtained at reduced tube currents (120-144 mAs). These baseline low-dose CT images were postprocessed with six noise reduction filters; the resulting postprocessed images were then randomly assorted with baseline images. Three radiologists performed independent evaluation of randomized images for presence, number, margins, attenuation, conspicuity, calcification, and enhancement of lesions, as well as image noise. Side-by-side comparison of baseline images with postprocessed images was performed by using a five-point scale for assessing lesion conspicuity and margins, image noise, beam hardening, and diagnostic acceptability. Quantitative noise and contrast-to-noise ratio were obtained for all liver lesions. Statistical analysis was performed by using the Wilcoxon signed rank test, Student t test, and kappa test of agreement. Significant reduction of noise was observed in images postprocessed with filter F compared with the noise in baseline nonfiltered images (P =.004). Although the number of lesions seen on baseline images and that seen on postprocessed images were identical, lesions were less conspicuous on postprocessed images than on baseline images. A decrease in quantitative image noise and contrast-to-noise ratio for liver lesions was noted with all noise reduction filters. There was good interobserver agreement (kappa = 0.7). Although the use of currently available noise reduction filters improves image noise and ameliorates beam-hardening artifacts at low-dose CT, such filters are limited by a compromise in lesion conspicuity and appearance in comparison with lesion conspicuity and appearance on baseline low-dose CT images. Copyright RSNA, 2004

  9. FDG-PET/CT can rule out malignancy in patients with vocal cord palsy.

    PubMed

    Thomassen, Anders; Nielsen, Anne Lerberg; Lauridsen, Jeppe Kiilerich; Blomberg, Björn Alexander; Hess, Søren; Petersen, Henrik; Johansen, Allan; Asmussen, Jon Thor; Sørensen, Jesper Roed; Johansen, Jørgen; Godballe, Christian; Høilund-Carlsen, Poul Flemming

    2014-01-01

    The aim was to investigate the performance of (18)F-fluorodeoxyglucose PET/CT to rule out malignancy in patients with confirmed vocal cord palsy (VCP). Between January 2011 and June 2013, we retrospectively included consecutive patients referred to PET/CT with paresis or paralysis of one or both vocal cords. PET/CT results were compared to clinical workup and histopathology. The study comprised 65 patients (32 females) with a mean age of 66±12 years (range 37-89). Eleven patients (17%) had antecedent cancer. Twenty-seven (42%) were diagnosed with cancer during follow-up. The palsy was right-sided in 24 patients, left-sided in 37, and bilateral in 4. Median follow-up was 7 months (interquartile range 4-11 months). Patients without cancer were followed for at least three months. PET/CT suggested a malignancy in 35 patients (27 true positives, 8 false positives) and showed none in 30 (30 true negatives, 0 false negatives). Thus, the sensitivity, specificity, positive and negative predictive values, and accuracy were (95% confidence intervals in parenthesis): 100% (88%-100%), 79% (64%-89%), 77% (61%-88%), 100% (89%-100%), and 88% (78%-94%), respectively. Sixteen patients had palliative treatment, while 11 were treated with curative intent, emphasising the severity of VCP and the need for a rapid and accurate diagnostic work-up. In this retrospective survey, biopsy proven malignancy (whether newly diagnosed or relapsed) was the cause of VCP in almost half of patients (42%). PET/CT had a high sensitivity (100%) with a relatively high false positive rate, but was excellent in ruling out malignancy (negative predictive value 100%).

  10. Evaluation of Eyeball and Orbit in Relation to Gender and Age.

    PubMed

    Özer, Cenk Murat; Öz, Ibrahim Ilker; Şerifoğlu, Ismail; Büyükuysal, Mustafa Çağatay; Barut, Çağatay

    2016-11-01

    The orbital aperture is the entrance to the orbit in which most important visual structures such as the eyeball and the optic nerve are found. It is vital not only for the visual system but also for the evaluation and recognition of the face. Eyeball volume is essential for diagnosing microphthalmos or buphthalmos in several eye disorders. Knowing the length of the optic nerve is necessary in selecting the right instruments for enucleation. Therefore, the aim of this study was to evaluate eyeball volume, orbital aperture, and optic nerve dimensions for a morphological description in a Turkish population sample according to gender and body side.Paranasal sinus computed tomography (CT) scans of 198 individuals (83 females, 115 males) aged between 5 and 74 years were evaluated retrospectively. The dimensions of orbital aperture, axial length and volume of eyeball, and diameter and length of the intraorbital part of the optic nerve were measured. Computed tomography examinations were performed on an Activion 16 CT Scanner (Toshiba Medical Systems, 2008 Japan). The CT measurements were calculated by using OsiriX software on a personal computer. All parameters were evaluated according to gender and right/left sides. A statistically significant difference between genders was found with respect to axial length of eyeball, optic nerve diameter, dimensions of orbital aperture on both sides, and right optic nerve length. Furthermore, certain statistically significant side differences were also found. There were statistically significant correlations between age and the axial length of the eyeball, optic nerve diameter, and the transverse length of the orbital aperture on both sides for the whole study group.In this study we determined certain morphometric parameters of the orbit. These outcomes may be helpful in developing a database to determine normal orbit values for the Turkish population so that quantitative assessment of orbital disease and orbital deformities will be evaluated both for preoperative planning and for assessing postoperative outcomes.

  11. A disappearing left-sided neck mass

    PubMed Central

    Lutwak, Nancy; Dill, Curt

    2012-01-01

    The patient was a 48-year-old man who presented to the emergency department with complaints of a left-sided painful neck mass, which changed in size relative to ingestion of meals. He denied voice change, fever, chills, weight loss, dysphagia and hoarseness. Physical examination was unremarkable. CT scan demonstrated a 3.9 mm calculus of the submandibular gland duct. Therapeutic sialendocopy was successfully performed. PMID:22764156

  12. Syntheses of some α-cyclic tripeptides as potential inhibitors for HMG-CoA Reductase.

    PubMed

    Chakraborty, Subrata; Lin, Shih-Hung; Shiuan, David; Tai, Dar-Fu

    2015-08-01

    α-Cyclic tripeptides (CtPs) are the most rigid members of the cyclic peptide family. However, due to their synthetic difficulty, biological activity has remained undisclosed. The incorporation of side-chain-protected natural amino acids into functional CtPs was performed to explore the potential biological functions. Several novel CtPs that consist of protected serine (S(Bn)) and/or glutamate (E(OBn)) were prepared from corresponding linear tripeptides by chemical synthesis. There is a strong possibility for CtPs that contain 3 phenyl groups to correlate with atorvastatin structure. The binding effects in human HMG-CoA reductase (hHMGR) activities were first evaluated by molecular docking. High docking scores were received with these CtPs for enzyme. Therefore, enzymatic assays were carried out and the compound cyclo(S(Bn))3 was indeed able to moderately inhibit hHMGR (IC50 = 110 μM).

  13. Tailored chemotherapy information faxed to general practitioners improves confidence in managing adverse effects and satisfaction with shared care: results from a randomized controlled trial.

    PubMed

    Jefford, Michael; Baravelli, Carl; Dudgeon, Paul; Dabscheck, Adrian; Evans, Melanie; Moloney, Michael; Schofield, Penelope

    2008-05-10

    General practitioners (GPs) play a critical role in the treatment of patients with cancer; yet often lack information for optimal care. We developed standardized information for GPs about chemotherapy (CT). In a randomized controlled trial we assessed the impact of sending, by fax, information tailored to the particular patient's CT regimen. Primary end points were: confidence treating patients who were receiving CT (confidence), knowledge of adverse effects and reasons to refer the patient to the treatment center (knowledge), and satisfaction with information and shared care of patients (satisfaction). Focus group work informed the development of the CT information which focused on potential adverse effects and recommended management strategies. GPs of patients due to commence CT were randomly assigned to receive usual correspondence with or without the faxed patient/regimen-specific information. Telephone questionnaire at baseline and 1 week postintervention assessed knowledge, confidence, and satisfaction. Ninety-seven GPs managed 97 patients receiving 23 types of CT. Eighty-one (83.5%) completed the follow-up questionnaire. GPs in the intervention group demonstrated a significantly greater increase in confidence (mean difference, 0.28; 95% CI, 0.10 to 0.47) and satisfaction (mean difference, 0.57; 95% CI, 0.27 to 0.88) compared with usual care, reflecting a 7.1% and 10.5% difference in score, respectively. No differences were detected for knowledge. GPs receiving the CT sheet found correspondence significantly more useful (P < .001) and instructive (P < .001) than GPs who received standard correspondence alone. Information about CT faxed to GPs is a simple, inexpensive intervention that increases confidence managing CT adverse effects and satisfaction with shared care. This intervention could have widespread application.

  14. [Testicular cancer: a model to optimize the radiological follow-up].

    PubMed

    Stebler, V; Pauchard, B; Schmidt, S; Valerio, M; De Bari, B; Berthold, D

    2015-05-20

    Despite being rare cancers, testicular seminoma and non-seminoma play an important role in oncology: they represent a model on how to optimize radiological follow-up, aiming at a lowest possible radiation exposure and secondary cancer risk. Males diagnosed with testicular cancer undergo frequently prolonged follow-up with CT-scans with potential toxic side effects, in particular secondary cancers. To reduce the risks linked to ionizing radiation, precise follow-up protocols have been developed. The number of recommended CT-scanners has been significantly reduced over the last 10 years. The CT scanners have evolved technically and new acquisition protocols have the potential to reduce the radiation exposure further.

  15. PET/CT in Radiation Therapy Planning.

    PubMed

    Specht, Lena; Berthelsen, Anne Kiil

    2018-01-01

    Radiation therapy (RT) is an important component of the management of lymphoma patients. Most lymphomas are metabolically active and accumulate 18 F-fluorodeoxyglucose (FDG). Positron emission tomography with computer tomography (PET/CT) imaging using FDG is used routinely in staging and treatment evaluation. FDG-PET/CT imaging is now also used routinely for contouring the target for RT, and has been shown to change the irradiated volume significantly compared with CT imaging alone. Modern advanced imaging techniques with image fusion and motion management in combination with modern highly conformal RT techniques have increased the precision of RT, and have made it possible to reduce dramatically the risks of long-term side effects of treatment while maintaining the high cure rates for these diseases. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. [A Case of Ruptured Internal Carotid-Posterior Communicating Artery Aneurysm Associated with Acute Subdural Hematoma, Extending from the Interhemispheric Space to the Posterior Fossa].

    PubMed

    Otsuka, Hiroaki; Fukuda, Yuhtaka; Yoshimura, Shouta; Somagawa, Chika; Hiu, Takeshi; Ono, Tomonori; Ushijima, Ryujirou; Toda, Keisuke; Tsutsumi, Keisuke

    2016-06-01

    A 69-year-old woman was admitted to our hospital because of a sudden severe headache without a history of head trauma. CT and MRI revealed an acute subdural hematoma (ASDH) extending from the right interhemispheric space to the posterior fossa bilaterally, with a small amount of subarachnoid hemorrhage that was predominantly localized to the left side of the basal cistern. CT angiogram demonstrated a long protruding ruptured aneurysm at the junction of the right internal carotid and posterior communicating arteries (IC/PC AN) with a posteroinferior projection, associated with a small bleb located near the tentorial edge close to the ipsilateral posterior clinoid process, for which she received clipping surgery. Though rare, IC/PC AN could cause pure or nearly pure ASDH in the above-mentioned distribution. Therefore, in patients with such ASDH, especially without a history of head injury or precise information regarding the situation at the time of onset, urgent imaging evaluation and early intervention are essential to prevent devastating re-rupture events.

  17. Volumetric analysis of maxillary sinuses of Zulu and European crania by helical, multislice computed tomography.

    PubMed

    Fernandes, C L

    2004-11-01

    The volumes of the maxillary sinuses are of interest to surgeons operating endoscopically as variation in maxillary sinus volume may mean variation in anatomical landmarks. Other surgical disciplines, such as dentistry, maxillo-facial surgery and plastic surgery, may benefit from this information. To compare the maxillary sinus volumes of dried crania from cadavers of European and Zulu descent, with respect to ethnic group and gender. Helical, multislice computed tomography (CT) was performed using 1-mm coronal slices. The area for each slice was obtained by tracing the outline of each slice. The CT machine calculated a volume by totalling the slices for each sinus. Ethnic and gender variations were found in the different groups. It was found that European crania had significantly larger antral volumes than Zulu crania and men had larger volumes than women. Race and gender interaction was also assessed, as was maxillary sinus side. A variation in maxillary sinus volume between different ethnic groups and genders exists, and surgeons operating in this region should be aware of this.

  18. 18. VIEW NORTHEAST, SHAFT, CAM, AND OPERATING ARM FOR NORTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. VIEW NORTHEAST, SHAFT, CAM, AND OPERATING ARM FOR NORTH END LOCK, INBOARD SIDE OF WEST BASCULE GIRDER - Grand Street Bridge, Spanning Pequonnock River at Grand Street, Bridgeport, Fairfield County, CT

  19. TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Chan, F; Newman, B

    2014-06-15

    Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze themore » scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.« less

  20. Sublingual Nitroglycerin Administration in Coronary Computed Tomography Angiography: a Systematic Review.

    PubMed

    Takx, Richard A P; Suchá, Dominika; Park, Jakob; Leiner, Tim; Hoffmann, Udo

    2015-12-01

    To systematically investigate the literature for the influence of sublingual nitroglycerin administration on coronary diameter, the number of evaluable segments, image quality, heart rate and blood pressure, and diagnostic accuracy of coronary computed tomography (CT) angiography. A systematic search was performed in PubMed, EMBASE and Web of Science. The studies were evaluated for the effect of sublingual nitroglycerin on coronary artery diameter, evaluable segments, objective and subjective image quality, systemic physiological effects and diagnostic accuracy. Due to the heterogeneous reporting of outcome measures, a narrative synthesis was applied. Of the 217 studies identified, nine met the inclusion criteria: seven reported on the effect of nitroglycerin on coronary artery diameter, six on evaluable segments, four on image quality, five on systemic physiological effects and two on diagnostic accuracy. Sublingual nitroglycerin administration resulted in an improved evaluation of more coronary segments, in particular, in smaller coronary branches, better image quality and improved diagnostic accuracy. Side effects were mild and were alleviated without medical intervention. Sublingual nitroglycerin improves the coronary diameter, the number of assessable segments, image quality and diagnostic accuracy of coronary CT angiography without major side effects or systemic physiological changes. • Sublingual nitroglycerin administration results in significant coronary artery dilatation. • Nitroglycerin increases the number of evaluable coronary branches. • Image quality is improved the most in smaller coronary branches. • Nitroglycerin increases the diagnostic accuracy of coronary CT angiography. • Most side effects are mild and do not require medical intervention.

  1. Vertical position of the orbits in nonsyndromic plagiocephaly in childhood and its relation to vertical strabismus.

    PubMed

    Eveleens, Jordi R J; Mathijssen, Irene M; Lequin, Maarten H; Polling, Jan-Roelof; Looman, Caspar W N; Simonsz, Huibert J

    2011-01-01

    To determine the existence of a correlation between the vertical angle of strabismus and the vertical angle between the orbital axes in nonsyndromic plagiocephaly in childhood. Patients were included when diagnosed with plagiocephaly. Orthoptic measurements showed a vertical strabismus and three-dimensional computed tomographic (CT) imaging of the skull was available. Patients were excluded if plagiocephaly was part of a syndrome or if any surgical intervention had taken place before our measurements. Three-dimensional CT imaging was used to calculate the vertical angle between the orbital axes in 3 reference planes (VAO) perpendicular to a line of reference through the lower borders of the maxilla (VAOmax), both auditory canals (VAOaud), and the lower points of the external occipital protuberances (VAOocc). Fourteen patients were included (mean age, 14 mo). Three-dimensional CT measurements showed a mean (SD) VAOmax of 1.70 (2.31) degrees, VAOaud of -1.54 (1.46) degrees, and VAOocc of -2.06 (4.29) degrees (a negative value indicates that the eye on the affected side was situated lower in the head). The mean vertical angle of strabismus was -2.39 (4.69) degrees in gaze toward the affected side, 3.66 (3.77) degrees in gaze ahead, and 8.14 (5.63) degrees in gaze toward the nonaffected side. The Pearson test showed no significant correlations. The clinical observation that vertical strabismus in adult plagiocephaly is correlated with the vertical angle of the orbital axes could not be confirmed in young children.

  2. The Extended Nasoseptal Flap for Skull Base Reconstruction of the Clival Region: An Anatomical and Radiological Study

    PubMed Central

    Peris-Celda, Maria; Pinheiro-Neto, Carlos Diogenes; Funaki, Takeshi; Fernandez-Miranda, Juan C.; Gardner, Paul; Snyderman, Carl; Rhoton, Albert L.

    2013-01-01

    Objective Reconstruction of large clival defects after an endoscopic endonasal procedure is challenging. The objective is to analyze the morphology, indications, and limitations of the extended nasoseptal flap, which adds the nasal floor and inferior meatus mucosa, compared with the standard nasoseptal flap, for clival reconstruction. Design Twenty-seven sides of formalin-fixed anatomical specimens and 13 computed tomography (CT) scans were used. Under 0-degree endoscopic visualization, a standard flap on one side and an extended flap on the other side were performed, as well as exposure of the sella, cavernous sinus, and clival dura mater. Coverage of both flaps was assessed, and they were incised and extracted for measurements. Results The extended flap has two parts: septal and inferior meatal. The extended flaps are 20 mm longer and add 774 mm2 of mucosal area. They cover a clival defect from tuberculum to foramen magnum in 66.6% cases and from below the sella in 91.6%. They cover both parasellar and paraclival segments of the internal carotid arteries. The lateral inferior limits are the medial aspect of the hypoglossal canals and Eustachian tubes. CT scans can predict the need or limitation of an extended nasoseptal flap. Conclusions The nasal floor and inferior meatus mucosa adds a significant area for reconstruction of the clivus. A defect laterally beyond the hypoglossal canals is not likely covered with this variation of the flap. Preoperative CT scans are useful to guide the reconstruction techniques. PMID:24436940

  3. Comparison of computed tomography and complex motion tomography in the evaluation of cholesteatoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaffer, K.A.

    1984-08-01

    High-resolution axial and coronal computed tomographic (CT) scans were compared with coronal and sagittal complex motion tomograms in patients with suspected middle ear cholesteatomas. Information on CT scans equaled or exceeded that on conventional complex motion tomograms in 16 of 17 patients, and in 11 it provided additional information. Soft-tissue resolution was superior with CT. In 14 patients who underwent surgery, CT provided information that was valuable to the surgeon. On the basis of this study, high-resolution CT is recommended as the preferred method for evaluating most patients with cholesteatomas of the temporal bone.

  4. Four-Dimensional CT of the Diaphragm in Children: Initial Experience

    PubMed Central

    2018-01-01

    Objective To evaluate the technical feasibility of four-dimensional (4D) CT for the functional evaluation of the pediatric diaphragm. Materials and Methods In 22 consecutive children (median age 3.5 months, age range 3 days–3 years), 4D CT was performed to assess diaphragm motion. Diaphragm abnormalities were qualitatively evaluated and diaphragm motion was quantitatively measured on 4D CT. Lung density changes between peak inspiration and expiration were measured in the basal lung parenchyma. The diaphragm motions and lung density changes measured on 4D CT were compared between various diaphragm conditions. In 11 of the 22 children, chest sonography was available for comparison. Results Four-dimensional CT demonstrated normal diaphragm (n = 8), paralysis (n = 10), eventration (n = 3), and diffusely decreased motion (n = 1). Chest sonography demonstrated normal diaphragm (n = 2), paralysis (n = 6), eventration (n = 2), and right pleural effusion (n = 1). The sonographic findings were concordant with the 4D CT findings in 90.9% (10/11) of the patients. In diaphragm paralysis, the affected diaphragm motion was significantly decreased compared with the contralateral normal diaphragm motion (−1.1 ± 2.2 mm vs. 7.6 ± 3.8 mm, p = 0.005). The normal diaphragms showed significantly greater motion than the paralyzed diaphragms (4.5 ± 2.1 mm vs. −1.1 ± 2.2 mm, p < 0.0001), while the normal diaphragm motion was significantly smaller than the motion of the contralateral normal diaphragm in paralysis (4.5 ± 2.1 mm vs. 7.6 ± 3.8 mm, p = 0.01). Basal lung density change of the affected side was significantly smaller than that of the contralateral side in diaphragm paralysis (89 ± 73 Hounsfield units [HU] vs. 180 ± 71 HU, p = 0.03), while no significant differences were found between the normal diaphragms and the paralyzed diaphragms (136 ± 66 HU vs. 89 ± 73 HU, p = 0.1) or between the normal diaphragms and the contralateral normal diaphragms in paralysis (136 ± 66 HU vs. 180 ± 71 HU, p = 0.1). Conclusion The functional evaluation of the pediatric diaphragm is feasible with 4D CT in select children. PMID:29354007

  5. TH-EF-207A-06: High-Resolution Optical-CT/ECT Imaging of Unstained Mice Femur, Brain, Spleen, and Tumor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoon, S; Dewhirst, M; Oldham, M

    2016-06-15

    Purpose: Optical transmission and emission computed tomography (optical-CT/ECT) provides high-resolution 3D attenuation and emission maps in unsectioned large (∼1cm{sup 3}) ex vivo tissue samples at a resolution of 12.9µm{sup 3} per voxel. Here we apply optical-CT/ECT to investigate high-resolution structure and auto-fluorescence in a range of optically cleared mice organs, including, for the first time, mouse bone (femur), opening the potential for study of bone metastasis and bone-mediated immune response. Methods: Three BALBc mice containing 4T1 flank tumors were sacrificed to obtain spleen, brain, tumor, and femur. Tissues were washed in 4% PFA, fixed in EtOH solution (for 5, 10,more » 10, and 2 days respectively), and then optically cleared for 3 days in BABBs. The femur was also placed in 0.25M aqueous EDTA for 15–30 days to remove calcium. Optical-CT/ECT attenuation and emission maps at 633nm (the latter using 530nm excitation light) were obtained for all samples. Bi-telecentric optical-CT was compared side-by-side with conventional optical projection tomography (OPT) imaging to evaluate imaging capability of these two rival techniques. Results: Auto-fluorescence mapping of femurs reveals vasculatures and fluorescence heterogeneity. High signals (A.U.=10) are reported in the medullary cavity but not in the cortical bone (A.U.=1). The brain strongly and uniform auto-fluoresces (A.U.=5). Thick, optically dense organs such as the spleen and the tumor (0.12, 0.46OD/mm) are reconstructed at depth without significant loss of resolution, which we attribute to the bi-telecentric optics of optical-CT. The attenuation map of tumor reveals vasculature, attenuation heterogeneity, and possibly necrotic tissue. Conclusion: We demonstrate the feasibility of optical-CT/ECT imaging of un-sectioned mice bones (femurs) and spleen with high resolution. This result, and the characterization of unstained organs, are important steps enabling future studies involving optical-CT/ECT applied to study metastasis and immunologic responses via fluorescence staining.« less

  6. Synchronous development of HCC and CCC in the same subsegment of the liver in a patient with type C liver cirrhosis.

    PubMed

    Watanabe, Takuya; Sakata, Jun; Ishikawa, Takashi; Shirai, Yoshio; Suda, Takeyasu; Hirono, Haruka; Hasegawa, Katsuhiko; Soga, Kenji; Shibasaki, Koichi; Saito, Yukifumi; Umezu, Hajime

    2009-10-31

    As a result of having undergone computed tomography (CT), a 75-year-old woman with type-C liver cirrhosiswas shown to have two tumors on the ventral and dorsal sides of subsegment 3 (S3). The tumor on the ventral side was diagnosed as a classic hepatocellular carcinoma (HCC), while that on the dorsal side was considered atypical for a HCC. Although the indocyanine green (ICG) findings indicated poor hepatic reserve, the prothrombin time (PT) was relatively good. An operation was performed in February 2007; however, this resulted in exploratory laparotomy. Dynamic CT performed 12 mo after the operation revealed that the tumor on the dorsal side of S3 had apparently increased. The marginal portion of the tumor was shown to be in the early and parenchymal phases, while the internal portion was found to have grown only slightly in the delayed phase. We diagnosed this tumor as a cholangiocellular carcinoma (CCC). S3 subsegmentectomy was performed in April 2008. The tumor on the ventral side was pathologically diagnosed as a moderately differentiated HCC, and that on the dorsal side was diagnosed as a CCC. We can therefore report a rare case of synchronous development of HCC and CCC in the same subsegment of the liver in a patient with type-C liver cirrhosis. We also add a literature review for all the reported cases published in Japan and around the world, and summarize the features of double cancer exhibiting both HCC and CCC.

  7. Site and Severity of the Increased Humeral Retroversion in Symptomatic Baseball Players: A 3-dimensional Computed Tomographic Analysis.

    PubMed

    Itami, Yasuo; Mihata, Teruhisa; Shibano, Koji; Sugamoto, Kazuomi; Neo, Masashi

    2016-07-01

    Humeral retroversion in baseball players is greater in the dominant shoulder than in the nondominant shoulder. However, the site and severity of the humeral rotational deformity remain unclear. To evaluate the site of side-to-side differences in humeral retroversion in baseball players and the severity of these changes through 3-dimensional computed tomographic (3D CT) bone models. Cross-sectional study; Level of evidence, 3. From 2008 to 2014, we studied 25 baseball players (12 pitchers, 13 fielders) who underwent surgery for throwing-related injuries (shoulder injury, 15 players; elbow injury, 10 players). The mean age (±SD) at the time of surgery was 20.0 ± 5.9 years. A reconstructed 3D CT model of the entire humerus was divided into 15 segments of equal height (overall mean, 21.4 ± 1.0 mm). The side-to-side difference in humeral retroversion in each segment was calculated by superimposing the model of the dominant side over the mirror-image model of the nondominant side. The overall mean increase in humeral retroversion was 13.0° ± 6.2° on the dominant side. Significant side-to-side differences in retroversion were present throughout the humerus. The largest side-to-side difference in humeral retroversion was seen at the insertions of the internal rotator muscles (2.5° ± 4.3°) and around the proximal physis (2.5° ± 1.4°). At the insertions of shoulder capsule and rotator cuff tendons, the superior half of the humeral head was more retroverted than the inferior half (P < .0001). The side-to-side difference in humeral retroversion was significantly greater in the pitchers (16.2° ± 5.1°) than in the fielders (10.0° ± 5.7°) (P = .009), particularly at the proximal physis. Baseball players exhibited significant side-to-side differences in humeral retroversion at multiple sites throughout the humerus, including the proximal humerus near the epiphyseal plate and at the insertions of the internal rotator muscles, the middle of the humeral shaft, and the distal third of the humerus. Therefore, the increased humeral retroversion at multiple sites throughout the humerus needs to be considered when we perform physical examinations, provide treatment, or undertake biomechanical studies for any throwing-related injuries. © 2016 The Author(s).

  8. 7. Historic American Buildings Survey (Fed.) Stanley P. Mixon, Photographer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Historic American Buildings Survey (Fed.) Stanley P. Mixon, Photographer Sept 16, 1940 (G) EXTERIOR, DETAIL OF OLD TAVERN SIGN (ENGLISH SIDE) WITH PAINTED LION - Captain Arah Phelphs Inn, Colebrook, Litchfield County, CT

  9. The treatment of pseudoaneurysms with flow diverters after malignant otitis externa.

    PubMed

    Németh, Tamás; Szakács, László; Bella, Zsolt; Majoros, Valéria; Barzó, Pál; Vörös, Erika

    2017-12-01

    Background We report a case of bilateral malignant otitis externa complicated with bilateral petrous internal carotid artery pseudoaneurysms and their successful treatment with a flow diverter. Case report A 68-year-old woman with serious complications of type II diabetes mellitus had malignant otitis externa on the right side. She was treated with combined antibiotic therapy and underwent mastoidectomy for mastoiditis. She presented at our hospital with acute hemorrhage from the right external auditory canal. The emergency computed tomography (CT) angiography revealed a multiobulated pseudoaneurysm at the petrous segment of the right internal carotid artery. The pseudoaneurysm was treated with a 5 × 40-mm Surpass flow diverter. Three months later, she developed a malignant external otitis on the left side. As the infection progressed, a left-sided mastoiditis, a brain abscess, and a pseudoaneurysm at the petrous segment of the left internal carotid artery developed. The pseudoaneurysm caused bleeding from the left ear, and was treated with a 5 × 50-mm Surpass flow diverter. No recurrent bleeding was observed. Four months later, a follow-up angiography showed complete occlusion of the pseudoaneurysm on the left side, but a residual aneurysm could be detected on the right side. One year after the first intervention, the follow-up CT and magnetic resonance angiography revealed the complete occlusion of the aneurysms bilaterally. Conclusion The use of a flow diverter appears to be an efficient and safe method to occlude carotid pseudoaneurysms even in an inflammatory milieu.

  10. Lumbar Osteophyte Avid on 68Ga-Prostate-Specific Membrane Antigen PET/CT.

    PubMed

    Jochumsen, Mads Ryø; Madsen, Michael Alle; Gammelgaard, Lise; Bouchelouche, Kirsten

    2018-06-01

    A 75-year-old man with recently diagnosed high-risk prostate cancer was referred for primary staging with Ga-prostate-specific membrane antigen (PSMA) PET/CT. The scan revealed intense Ga-PSMA uptake in a lumbar osteophyte on the right side of level L2/L3, whereas several other spinal osteophytes showed no Ga-PSMA uptake. MRI findings in the L3 vertebra was consistent with a benign Modic type 1 lesion, but MRI showed no signs of malignancy in the osteophyte with high Ga-PMSA uptake. This case presents an osteophyte as an addition to the list of potential benign pitfalls to be aware of when interpreting Ga-PSMA PET/CT.

  11. Nondestructive observation of teeth post core-space using optical coherence tomography: comparison with microcomputed tomography and live images

    NASA Astrophysics Data System (ADS)

    Minamino, Takuya; Mine, Atsushi; Matsumoto, Mariko; Sugawa, Yoshihiko; Kabetani, Tomoshige; Higashi, Mami; Kawaguchi, Asuka; Ohmi, Masato; Awazu, Kunio; Yatani, Hirofumi

    2015-10-01

    No previous reports have observed inside the root canal using both optical coherence tomography (OCT) and x-ray microcomputed tomography (μCT) for the same sample. The purpose of this study was to clarify both OCT and μCT image properties from observations of the same root canal after resin core build-up treatment. As OCT allows real-time observation of samples, gap formation may be able to be shown in real time. A dual-cure, one-step, self-etch adhesive system bonding agent, and dual-cure resin composite core material were used in root canals in accordance with instructions from the manufacturer. The resulting OCT images were superior for identifying gap formation at the interface, while μCT images were better to grasp the tooth form. Continuous tomographic images from real-time OCT observation allowed successful construction of a video of the resin core build-up procedure. After 10 to 12 s of light curing, a gap with a clear new signal occurred at the root-core material interface, proceeding from the coronal side (6 mm from the cemento-enamel junction) to the apical side of the root.

  12. Effects of corticopuncture (CP) and low-level laser therapy (LLLT) on the rate of tooth movement and root resorption in rats using micro-CT evaluation.

    PubMed

    Suzuki, Selly Sayuri; Garcez, Aguinaldo Silva; Reese, Patricia Oblitas; Suzuki, Hideo; Ribeiro, Martha Simões; Moon, Won

    2018-05-01

    The aim of this study was to compare the rate of tooth displacement, quantity of root resorption, and alveolar bone changes in five groups: corticopuncture (CP), low-level laser therapy (LLLT), CP combined with LLLT (CP + LLLT), control (C), and negative control (NC). A total of 60 half-maxilla from 30 male Wistar rats (10 weeks old) were divided randomly into five groups: three (CP, LLLT, and CP + LLLT) test groups with different stimulation for accelerated-tooth-movement (ATM), one control (C) group, and one negative control (NC) group with no tooth movement. Nickel-titanium coil springs with 50 g of force were tied from the upper left and right first molars to micro-implants placed behind the maxillary incisors. For the CP and CP + LLLT groups, two perforations in the palate and one mesially to the molars were performed. For the LLLT and CP + LLLT groups, GaAlAs diode laser was applied every other day for 14 days (810 nm, 100 mW, 15 s). The tooth displacements were measured directly from the rat's mouth and indirectly from microcomputer (micro-CT) tomographic images. Bone responses at the tension and compression sites and root resorption were analyzed from micro-CT images. The resulting alveolar bone responses were evaluated by measuring bone mineral density (BMD), bone volume fraction (BV/TV), and trabecular thickness (TbTh). Root resorption crater volumes were measured on both compression and tension sides of mesial and distal buccal roots. The tooth displacement in the CP + LLLT group was the greatest when measured clinically, followed by the CP, LLLT, and control groups (C and NC), respectively (p <0.05). The tooth movements measured from micro-CT images showed statistically higher displacement in the CP and CP + LLLT groups compared to the LLLT and control groups. The BMD, BV/TV, and TbTh values were lower at the compression side and higher at the tension side for all three test groups compared to the control group. The root resorption crater volume of the distal buccal root was higher in the control group, followed by CP, LLLT, and CP + LLLT, mostly at the compression site. Combining corticopuncture and low-level laser therapy (CP + LLLT) produced more tooth displacement and less root resorption at the compression side. The combined technique also promoted higher alveolar bone formation at the tension side.

  13. 44. OBLIQUE DETAIL VIEW OF STAMP BATTERIES AND APRONS, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. OBLIQUE DETAIL VIEW OF STAMP BATTERIES AND APRONS, LOOKING SOUTHWEST. THIS IS THE IDENTICAL PERSPECTIVE GIVEN I CA-290-43 (CT), BUT THIS IS A TIGHTER (CLOSER) SHOT. APRONS AND STAIRWAY ARE OMITTED. EACH BATTERY CONTAINS FIVE SAMPS. TWO OR THE THREE BATTERIES ARE SIDE BY SIDE IN FOREGROUND, WHILE THE THIRD BATTERY IS SEPARATE (LOWER RIGHT). - Skidoo Mine, Park Route 38 (Skidoo Road), Death Valley Junction, Inyo County, CA

  14. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma.

    PubMed

    Qi, Zhihua; Gates, Erica L; O'Brien, Maureen M; Trout, Andrew T

    2018-02-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations.

  15. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Zeniya, T.; Takeda, T.; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T.

    2001-07-01

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  16. Sacroplasty for symptomatic sacral hemangioma: a novel treatment approach. A case report.

    PubMed

    Agarwal, V; Sreedher, G; Weiss, K R; Hughes, M A

    2013-06-01

    Painful vertebral body hemangiomas have been successfully treated with vertebroplasty and kyphoplasty. Sacral hemangiomas are uncommon and as such painful sacral hemangiomas are rare entities. We report what we believe is only the second successful treatment of a painful sacral hemangioma with CT-guided sacroplasty. A 56-year-old woman with a history of right-sided total hip arthroplasty and lipoma excision presented to her orthopedic surgeon with persistent right-sided low back pain which radiated into her buttock and right groin and hindered her ability to walk and perform her activities of daily living. MRIs of the thoracic spine, lumbar spine and pelvis showed numerous lesions with imaging characteristics consistent with multiple hemangiomas including a 2.2×2.1 cm lesion involving the right sacrum adjacent to the right S1 neural foramen. Conservative measures including rest, physical therapy, oral analgesics and right-sided sacroiliac joint steroid injection did not provide significant relief. Given her lack of improvement and the fact that her pain localized to the right sacrum, the patient underwent CT-guided sacroplasty for treatment of a painful right sacral hemangioma. Under CT fluoroscopic guidance, a 10 gauge introducer needle was advanced through the soft tissues of the back to the margin of the lesion. Biopsy was then performed and after appropriate preparation, cement was then introduced through the needle using a separate cement filler cannula. Appropriate filling of the right sacral hemangioma was visualized using intermittent CT fluoroscopy. After injection of approximately 2.5 cc of cement, it was felt that there was near complete filling of the right sacral hemangioma. With satisfactory achievement of cement filling, the procedure was terminated. Pathology from biopsy taken at the time of the procedure was consistent with hemangioma. Image-guided sacroplasty with well-defined endpoints is an effective, minimally invasive and safe procedure. Patients with painful sacral hemangiomas can be treated with this technique with no significant complications.

  17. Sacroplasty for Symptomatic Sacral Hemangioma: A Novel Treatment Approach

    PubMed Central

    Agarwal, V.; Sreedher, G.; Weiss, K.R.; Hughes, M.A.

    2013-01-01

    Summary Painful vertebral body hemangiomas have been successfully treated with vertebroplasty and kyphoplasty. Sacral hemangiomas are uncommon and as such painful sacral hemangiomas are rare entities. We report what we believe is only the second successful treatment of a painful sacral hemangioma with CT-guided sacroplasty. A 56-year-old woman with a history of right-sided total hip arthroplasty and lipoma excision presented to her orthopedic surgeon with persistent right-sided low back pain which radiated into her buttock and right groin and hindered her ability to walk and perform her activities of daily living. MRIs of the thoracic spine, lumbar spine and pelvis showed numerous lesions with imaging characteristics consistent with multiple hemangiomas including a 2.2×2.1 cm lesion involving the right sacrum adjacent to the right S1 neural foramen. Conservative measures including rest, physical therapy, oral analgesics and right-sided sacroiliac joint steroid injection did not provide significant relief. Given her lack of improvement and the fact that her pain localized to the right sacrum, the patient underwent CT-guided sacroplasty for treatment of a painful right sacral hemangioma. Under CT fluoroscopic guidance, a 10 gauge introducer needle was advanced through the soft tissues of the back to the margin of the lesion. Biopsy was then performed and after appropriate preparation, cement was then introduced through the needle using a separate cement filler cannula. Appropriate filling of the right sacral hemangioma was visualized using intermittent CT fluoroscopy. After injection of approximately 2.5 cc of cement, it was felt that there was near complete filling of the right sacral hemangioma. With satisfactory achievement of cement filling, the procedure was terminated. Pathology from biopsy taken at the time of the procedure was consistent with hemangioma. Image-guided sacroplasty with well-defined endpoints is an effective, minimally invasive and safe procedure. Patients with painful sacral hemangiomas can be treated with this technique with no significant complications. PMID:23693051

  18. An integrated teaching method of gross anatomy and computed tomography radiology.

    PubMed

    Murakami, Tohru; Tajika, Yuki; Ueno, Hitoshi; Awata, Sachiko; Hirasawa, Satoshi; Sugimoto, Maki; Kominato, Yoshihiko; Tsushima, Yoshito; Endo, Keigo; Yorifuji, Hiroshi

    2014-01-01

    It is essential for medical students to learn and comprehend human anatomy in three dimensions (3D). With this in mind, a new system was designed in order to integrate anatomical dissections with diagnostic computed tomography (CT) radiology. Cadavers were scanned by CT scanners, and students then consulted the postmortem CT images during cadaver dissection to gain a better understanding of 3D human anatomy and diagnostic radiology. Students used handheld digital imaging and communications in medicine viewers at the bench-side (OsiriX on iPod touch or iPad), which enabled "pixel-to-tissue" direct comparisons of CT images and cadavers. Students had lectures and workshops on diagnostic radiology, and they completed study assignments where they discussed findings in the anatomy laboratory compared with CT radiology findings. This teaching method for gross and radiological anatomy was used beginning in 2009, and it yielded strongly positive student perspectives and significant improvements in radiology skills in later clinical courses. © 2014 American Association of Anatomists.

  19. 1. Historic American Buildings Survey (Fed.) Stanely P. Mixon, Photographer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Historic American Buildings Survey (Fed.) Stanely P. Mixon, Photographer Mar. 27, 1940 (A) EXT. GEN. VIEW OF SOUTH AND EAST SIDES - Captain Nathaniel Shaw Mansion, 11 Blinman Street, New London, New London County, CT

  20. 7. View northwest of smoke stack on Armory Street Pump ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. View northwest of smoke stack on Armory Street Pump House. - Lake Whitney Water Filtration Plant, Armory Street Pumphouse, North side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  1. Epidural Injections for Spinal Pain

    MedlinePlus

    ... then be positioned on your stomach or side on a special fluoroscopic or CT table that will give the doctor easy access to the injection site(s). A nurse and/or technologist will help to make you as comfortable as ...

  2. 9. POWERHOUSE, LOWER LEVEL, LOOKING NORTHWEST, PRESSURE CASE WHICH CONTAINS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. POWERHOUSE, LOWER LEVEL, LOOKING NORTHWEST, PRESSURE CASE WHICH CONTAINS THE WATER TURBINE - Dayville Mills Hydroelectric Facility, Powerhouse, North side of Route 101, .5 mile west of Route 395, Killingly Center, Windham County, CT

  3. Effects of aging on the structural, mechanical, and thermal properties of the silicone rubber current transformer insulation bushing for a 500 kV substation.

    PubMed

    Wang, Zhigao; Zhang, Xinghai; Wang, Fangqiang; Lan, Xinsheng; Zhou, Yiqian

    2016-01-01

    In order to analyze the cracking and aging reason of the silicone rubber current transformer (CT) insulation bushing used for 8 years from a 500 kV alternating current substation, characteristics including Fourier transform infrared (FTIR) spectroscopy, mechanical properties analysis, hardness, and thermo gravimetric analysis have been carried out. The FTIR results indicated that the external surface of the silicone rubber CT insulation bushing suffered from more serious aging than the internal part, fracture of side chain Si-C bond was much more than the backbone. Mechanical properties and thermal stability results illustrated that the main aging reasons were the breakage of side chain Si-C bond and the excessive cross-linking reaction of the backbone. This study can provide valuable basis for evaluating degradation mechanism and aging state of the silicone rubber insulation bushing in electric power field.

  4. Porous polymethylmethacrylate as bone substitute in the craniofacial area.

    PubMed

    Bruens, Marco L; Pieterman, Herman; de Wijn, Joost R; Vaandrager, J Michael

    2003-01-01

    In craniofacial surgery, alloplastic materials are used for correcting bony defects. Porous polymethylmethacrylate (PMMA) is a biocompatible and nondegradable bone cement. Porous PMMA is formed by the classic bone cement formulation of methylmethacrylate liquid and PMMA powder in which an aqueous biodegradable carboxymethylcellulose gel is dispersed to create pores in the cement when cured. Pores give bone the opportunity to grow in, resulting in a better fixation of the prostheses. We evaluated the long-term results (n = 14), up to 20 years, of augmentations and defect fillings in the craniofacial area, with special interest in possible side effects and bone ingrowth. The evaluation consisted of a questionnaire, a physical examination, and a computed tomography (CT) scan. There were no side effects that could be ascribed to the porous PMMA. Twelve CT scans showed bone ingrowth into the prostheses, proving the validity behind the concept of porous PMMA.

  5. Effect of wet-cold weather transportation conditions on thermoregulation and the development of accidental hypothermia in pullets under tropical conditions

    NASA Astrophysics Data System (ADS)

    Minka, Ndazo S.; Ayo, Joseph O.

    2016-03-01

    The present study examines onboard thermal microclimatic conditions and thermoregulation of pullets exposed to accidental hypothermia during wet-cold weather transportation conditions, and the effect of rewarming on colonic temperature (CT) of the birds immediately after transportation. A total of 2200 pullets were transportation for 5 h in two separate vehicles during the nighttime. The last 3 h of the transportation period was characterized by heavy rainfall. During the precipitation period, each vehicle was covered one fourth way from the top-roof with a tarpaulin. The onboard thermal conditions inside the vehicles during transportation, which comprised ambient temperature and relative humidity were recorded, while humidity ratio and specific enthalpy were calculated. The CT of the birds was recorded before and after transportation. During transportation, onboard thermal heterogeneity was observed inside the vehicles with higher ( p < 0.05) values in the front and center, and lower values recorded at the air inlets at the sides and rear planes. The CT values recorded in birds at the front and center planes were between 42.2 and 42.5 °C, indicative of mild hypothermia; while lower CT values between 28 and 38 °C were recorded at the sides and rear planes, indicative of mild to severe hypothermia. Several hours of gradual rewarming returned the CT to normal range. The result, for the first time, demonstrated the occurrence of accidental hypothermia in transported pullets under tropical conditions and a successful rewarming outcome. In conclusion, transportation of pullets during wet weather at onboard temperature of 18-20 °C induced hypothermia on birds located at the air inlets, which recovered fully after several hours of gradual rewarming.

  6. Effect of wet-cold weather transportation conditions on thermoregulation and the development of accidental hypothermia in pullets under tropical conditions.

    PubMed

    Minka, Ndazo S; Ayo, Joseph O

    2016-03-01

    The present study examines onboard thermal microclimatic conditions and thermoregulation of pullets exposed to accidental hypothermia during wet-cold weather transportation conditions, and the effect of rewarming on colonic temperature (CT) of the birds immediately after transportation. A total of 2200 pullets were transportation for 5 h in two separate vehicles during the nighttime. The last 3 h of the transportation period was characterized by heavy rainfall. During the precipitation period, each vehicle was covered one fourth way from the top-roof with a tarpaulin. The onboard thermal conditions inside the vehicles during transportation, which comprised ambient temperature and relative humidity were recorded, while humidity ratio and specific enthalpy were calculated. The CT of the birds was recorded before and after transportation. During transportation, onboard thermal heterogeneity was observed inside the vehicles with higher (p < 0.05) values in the front and center, and lower values recorded at the air inlets at the sides and rear planes. The CT values recorded in birds at the front and center planes were between 42.2 and 42.5 °C, indicative of mild hypothermia; while lower CT values between 28 and 38 °C were recorded at the sides and rear planes, indicative of mild to severe hypothermia. Several hours of gradual rewarming returned the CT to normal range. The result, for the first time, demonstrated the occurrence of accidental hypothermia in transported pullets under tropical conditions and a successful rewarming outcome. In conclusion, transportation of pullets during wet weather at onboard temperature of 18-20 °C induced hypothermia on birds located at the air inlets, which recovered fully after several hours of gradual rewarming.

  7. CT Scans - Multiple Languages

    MedlinePlus

    ... Tomography) Scan - العربية (Arabic) Bilingual PDF Health Information Translations Chinese, Simplified (Mandarin dialect) (简体中文) Expand Section CT ( ... Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chinese, Traditional (Cantonese dialect) (繁體中文) Expand Section CT ( ...

  8. How Do Health Care Providers Diagnose Pheochromocytoma?

    MedlinePlus

    ... NICHD Research Information Find a Study More Information Pharmacology Condition Information NICHD Research Information Find a Study ... several imaging methods, including computed tomography (CT) and magnetic resonance imaging (MRI). CT scans use X-rays to produce ...

  9. Anterior loop of the inferior alveolar nerve: Averages and prevalence based on CT scans.

    PubMed

    Juan, Del Valle Lovato; Grageda, Edgar; Gómez Crespo, Salvador

    2016-02-01

    The treatment of edentulous patients by using a complete implant-supported fixed prosthetic with distal extension has been widely studied; success is mainly dependent upon the placement of the distal implants. The location of the inferior alveolar nerve determines implant placement, but the length, prevalence, and symmetry between the left and right side of the anterior loop of the alveolar nerve are unknown. The purpose of this clinical study was to measure the anterior loop of the inferior alveolar nerve, which determines the placement of distal implants, in a group of 55 Mexican participants. The study expected to ascertain the average length, prevalence, and symmetry between left and right side and any sex differences. To differentiate the inferior alveolar nerve path, a new technique was applied using Hounsfield unit (HU) thresholds. The null hypothesis was that no significant differences would be found between the left and right sides or between men and women for the anterior loop of the inferior alveolar nerve. Fifty-five computed tomography (CT) scans were made (Somatom Sensation 16; Siemens Healthcare) and were visualized with InVesalius software. Anterior loop measurements were made on 3-dimensional surfaces. To determine statistical differences between the left and right side and between the sexes, the t test was used. The interclass correlation coefficient test was also applied to verify the reliability of the measurements. Ninety percent of participants showed the anterior loop of the inferior alveolar nerve. The length of the anterior loop ranged between 0 and 6.68 mm, with a mean of 2.19 mm. No significant differences were found between the left and right sides or between men and women. The mean length for the anterior loop in the sample was 2.19 mm. As the anterior loop length shows a high degree of variability, these findings suggest that a CT scan for each patient is recommended in order to visualize a safety zone before placing implants close to the mental foramen. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Relationship between masticatory function and internal structure of the mandible based on computed tomography findings.

    PubMed

    Sato, Hidemasa; Kawamura, Akira; Yamaguchi, Masaru; Kasai, Kazutaka

    2005-12-01

    The purposes of this study were to investigate bone mineral density as a part of bone construction in human skulls and to examine the relationship between dentofacial morphology and masticatory function by using computed tomography (CT) findings. Changes in bone mineral density in the mandible because of loss of masticatory function were tested in rats by experimentally producing an environment that inhibited mastication by the molars. Data for the human study were obtained from 27 modern male Japanese skulls (mean age, 28 years) from the University of Tokyo. Cortical bone thickness (CBT) and CT value (CV) were measured by each CT scan of the first and molars. For the animal study, a metal cap was inserted between the maxillary and mandibular incisors to prevent the molars from biting in 6-week-old male Wistar rats. The rats were killed after 2, 4, or 6 weeks, and bone mineral density was measured in cancellous and cortical bone equivalent to the first molar region by using peripheral quantitative computed tomography. In the human skull study, significant negative correlations were observed between CV in the regions of the buccal side of the second molar and the angle between the Frankfort horizontal and mandibular planes. Significant negative correlations were also observed between the gonial angle and CV in the buccal and basal sides. In the animal study, cancellous bone mineral density began to decline 4 weeks after the start of the experiment in the masticatory hypofunction group compared with the control group. By week 6, cancellous bone density had declined by 11.6% on the buccal side, 16.7% on the lingual side, 12.3% at the bifurcation of the root, and 38.1% at the root apex. Cortical bone density declined by 8% to 12% on the lingual side. The results support our hypothesis that a functional adaptive response by the mandible to mechanical stress resulting from mastication occurs not only in the muscle insertion area, but also in mandibular alveolar bone in the molar region.

  11. Preoperative and Postoperative CT Scan Assessment of Pterygomaxillary Junction in Patients Undergoing Le Fort I Osteotomy: Comparison of Pterygomaxillary Dysjunction Technique and Trimble Technique-A Pilot Study.

    PubMed

    Dadwal, Himani; Shanmugasundaram, S; Krishnakumar Raja, V B

    2015-09-01

    To determine the rate of complications and occurrence of pterygoid plate fractures comparing two techniques of Le Fort I osteotomy i.e., Classic Pterygomaxillary Dysjunction technique and Trimble technique and to know whether the dimensions of pterygomaxillary junction [determined preoperatively by computed tomography (CT) scan] have any influence on pterygomaxillary separation achieved during surgery. The study group consisted of eight South Indian patients with maxillary excess. A total of 16 sides were examined by CT. Preoperative CT was analyzed for all the patients. The thickness and width of the pterygomaxillary junction and the distance of the greater palatine canal from the pterygomaxillary junction was noted. Pterygomaxillary dysjunction was achieved by two techniques, the classic pterygomaxillary dysjunction technique (Group I) and Trimble technique (Group II). Patients were selected randomly and equally for both the techniques. Dysjunction was analyzed by postoperative CT. The average thickness of the pterygomaxillary junction on 16 sides was 4.5 ± 1.2 mm. Untoward pterygoid plate fractures occurred in Group I in 3 sides out of 8. In Trimble technique (Group II), no pterygoid plate fractures were noted. The average width of the pterygomaxillary junction was 7.8 ± 1.5 mm, distance of the greater palatine canal from pterygomaxillary junction was 7.4 ± 1.6 mm and the length of fusion of pterygomaxillary junction was 8.0 ± 1.9 mm. The Le Fort I osteotomy has become a standard procedure for correcting various dentofacial deformities. In an attempt to make Le Fort I osteotomy safer and avoid the problems associated with sectioning with an osteotome between the maxillary tuberosity and the pterygoid plates, Trimble suggested sectioning across the posterior aspect of the maxillary tuberosity itself. In our study, comparison between the classic pterygomaxillary dysjunction technique and the Trimble technique was made by using postoperative CT scan. It was found that unfavorable pterygoid plate fractures occurred only in dysjunction group and not in Trimble technique group. Preoperative CT scan assessment was done for all the patients to determine the dimension of the pterygomaxillary region. Preoperative CT scan proved to be helpful in not only determining the dimensions of the pterygomaxillary region but we also found out that thickness of the pterygomaxillary junction was an important parameter which may influence the separation at the pterygomaxillary region. No untoward fractures of the pterygoid plates were seen in Trimble technique (Group II) which makes it a safer technique than classic dysjunction technique. It was noted that pterygoid plate fractures occurred in patients in whom the thickness of the pterygomaxillary junction was <3.6 mm (preoperatively). Therefore, preoperative evaluation is important, on the basis of which we can decide upon the technique to be selected for safer and acceptable separation of pterygomaxillary region.

  12. Sensitivity and positive predictive value of CT, MRI and 123I-MIBG scintigraphy in localizing pheochromocytomas: a prospective study.

    PubMed

    Lumachi, Franco; Tregnaghi, Alberto; Zucchetta, Pietro; Cristina Marzola, Maria; Cecchin, Diego; Grassetto, Gaia; Bui, Franco

    2006-07-01

    To establish a standardized non-invasive imaging protocol for patients with pheochromocytoma undergoing surgery. A series of 32 consecutive patients (16 men, 16 women; median age 43 years, range 15-71 years) with biochemically confirmed pheochromocytoma underwent computed tomography (CT) scanning, magnetic resonance imaging (MRI) and meta-[I]iodobenzylguanidine (MIBG) whole-body scintigraphy prior to adrenalectomy or excision of extra-adrenal tumour (paraganglioma). At final pathology no malignant pheochromocytomas were found. The tumour was right-sided in 16 (50%) patients, left-sided in 13 (41%), extra-adrenal (sympathetic ganglia, upper abdomen) in two (6%) and bilateral in one (3%) patient. Overall, the median greatest diameter (size) of the tumour was 35 mm (range, 15-90 mm). The sensitivity of CT, MRI and MIBG scintigraphy was 90%, 93% and 91%, and the specificity was 93%, 93% and 100%, respectively. The three patients with false negative scintigraphy had an intra-adrenal tumour, ranging from 20 to 50 mm in size. The presence of necrosis within the mass might justify the lack of significant uptake of radiopharmaceutical in two patients, and the small size (15 mm) of the mass in the other. There were two false positive results with both CT and MRI, and no false positive MIBG scintigraphy, which had the highest (100%) positive predictive value. The combination of MRI+MIBG scintigraphy reached 100% sensitivity and positive predictive value. Our data suggest that this imaging protocol should be used in all patients with biochemically confirmed pheochromocytoma.

  13. Synchrotron X-ray studies of the keel of the short-spined sea urchin Lytechinus variegatus: absorption microtomography (microCT) and small beam diffraction mapping.

    PubMed

    Stock, S R; Barss, J; Dahl, T; Veis, A; Almer, J D; Carlo, F

    2003-05-01

    In sea urchin teeth, the keel plays an important structural role, and this paper reports results of microstructural characterization of the keel of Lytechinus variegatus using two noninvasive synchrotron x-ray techniques: x-ray absorption microtomography (microCT) and x-ray diffraction mapping. MicroCT with 14 keV x-rays mapped the spatial distribution of mineral at the 1.3 microm level in a millimeter-sized fragment of a mature portion of the keel. Two rows of low absorption channels (i.e., primary channels) slightly less than 10 microm in diameter were found running linearly from the flange to the base of the keel and parallel to its sides. The primary channels paralleled the oral edge of the keel, and the microCT slices revealed a planar secondary channel leading from each primary channel to the side of the keel. The primary and secondary channels were more or less coplanar and may correspond to the soft tissue between plates of the carinar process. Transmission x-ray diffraction with 80.8 keV x-rays and a 0.1 mm beam mapped the distribution of calcite crystal orientations and the composition Ca(1-x)Mg(x)CO(3) of the calcite. Unlike the variable Mg concentration and highly curved prisms found in the keel of Paracentrotus lividus, a constant Mg content (x = 0.13) and relatively little prism curvature was found in the keel of Lytechinus variegatus.

  14. Light scattering in optical CT scanning of Presage dosimeters

    NASA Astrophysics Data System (ADS)

    Xu, Y.; Adamovics, J.; Cheeseborough, J. C.; Chao, K. S.; Wuu, C. S.

    2010-11-01

    The intensity of the scattered light from the Presage dosimeters was measured using a Thorlabs PM100D optical power meter (Thorlabs Inc, Newton, NJ) with an optical sensor of 1 mm diameter sensitive area. Five Presage dosimeters were made as cylinders of 15.2 cm, 10 cm, 4 cm diameters and irradiated with 6 MV photons using a Varian Clinac 2100EX. Each dosimeter was put into the scanning tank of an OCTOPUS" optical CT scanner (MGS Research Inc, Madison, CT) filled with a refractive index matching liquid. A laser diode was positioned at one side of the water tank to generate a stationary laser beam of 0.8 mm width. On the other side of the tank, an in-house manufactured positioning system was used to move the optical sensor in the direction perpendicular to the outgoing laser beam from the dosimeters at an increment of 1 mm. The amount of scattered photons was found to be more than 1% of the primary light signal within 2 mm from the laser beam but decreases sharply with increasing off-axis distance. The intensity of the scattered light increases with increasing light attenuations and/or absorptions in the dosimeters. The scattered light at the same off-axis distance was weaker for dosimeters of larger diameters and for larger detector-to-dosimeter distances. Methods for minimizing the effect of the light scattering in different types of optical CT scanners are discussed.

  15. The Results of the Surgical Treatment of Spontaneous Rhinorrhea via Craniotomy and the Contribution of CT Cisternography to the Detection of Exact Leakage Side of CSF.

    PubMed

    Tumturk, Abdulfettah; Ulutabanca, Halil; Gokoglu, Abdulkerim; Oral, Sukru; Menku, Ahmet; Kurtsoy, Ali

    2016-01-01

    To share the results of conventional surgery in rhinorrhea and the contribution of computerized tomography (CT) cisternography to determination of the site of cerebrospinal fluid (CSF) leak. Twelve cases treated for spontaneous rhinorrhea were included in this study. All the cases underwent cranial CT and magnetic resonance imaging (MRI). CT cisternography was performed in four patients whose bone defect or leakage site could not be detected by CT and MRI. In order to repair the defect, either the galea or galea together with collagen matrix was used and the procedure was supported with fibrin glue. In the cases, postoperative rhinorrhea was seen in neither the early nor the late follow up period. We observed no complications related to CT cisternography or craniotomy. The leakage area was successfully detected with CT cisternography when the other methods failed. Bone defect can usually be shown by means of CT. However, when bone-defect cannot be shown or the dura in the defective area is intact, CT cisternography is useful to show the CSF leak. Conventional surgery was very succesful in the treatment of spontaneous rhinorrhea but it was cosmetically problematic. In the patients both treated with galea and galea together with collagen matrix, the repair of the defect was successful.

  16. [Condylar hyperplasia: qualitative and quantitative study of temporomandibular joints remodeling before and after condylectomy].

    PubMed

    Rojare, Camille; Wojcik, Thomas; Coussens, Camille; Ferri, Joël; Pertuzon, Bruno; Raoul, Gwénaël

    2014-06-01

    This retrospective study aimed to evaluate bone remodeling of temporo-mandibular joints (TMJ) using computed tomography (CT) before and after condylectomy for condylar hyperplasia. TMJ bone remodeling was studied by comparing the pre and postoperative CT scan of ten patients. Qualitative evaluation was performed by two-dimensional analysis. Three-dimensional analysis superimpositions were done after digital condylar units isolation. Condylar volume modifications were measured and compared on both sides. Lastly, before and after surgery, we studied the radio-clinic correlations. After surgery, all the operated condyles developed a new cortical bone. We noticed also a thickening of the glenoid fossa. Surgical condylectomy leaded to a 43.5% volume reduction on the operated side and 2.14% on the controlateral side. On the controlateral side, most of abnormalities seen preoperatively disappeared after surgery. For two patients, the condylar resection took away over 80% of the initial volume. For these patients, we observed major radiologic modifications on the controlateral TMJ associated with symptoms of dysfunction. These problems did not worsen their quality of life. Both TMJ presented with bone remodelling after condylectomy. In condylar hyperplasia, condylectomy provides orthopaedic results on dysmorphia and removal of the pathological prechondroblastic zone. In the future, an earlier detection of this pathology may help the surgeon to treat in childhood. This would limit surgical excision and would avoid important dysmorphia. © EDP Sciences, SFODF, 2014.

  17. The posterior communicating artery: morphometric study in 3D angio-computed tomography reconstruction. The proof of the mathematical definition of the hypoplasia.

    PubMed

    Dzierżanowski, J; Szarmach, A; Słoniewski, P; Czapiewski, P; Piskunowicz, M; Bandurski, T; Szmuda, T

    2014-08-01

    The aim of this study was to investigate the morphometry of the posterior communicating artery (PCoA), on the basis of angio-computed tomography (CT), and to give proof of the mathematical definition of the term "hypopal sia of the PCoA". One hundred 3-dimensional (3D) angio-CT images, performed in adult patients with bilateral reconstruction of the PCoA (200 results) were used tocalculate the morphometry of the vessel. The average length of the vessel on the right side was 14.48 ± 3.47 mm, andon the left side 14.98 ± 4.77 mm (in women 14.75 mm, in men 14.70 mm). The mean of the diameter at the "proximal" point (the junction with P1) on the right side was 1.49 ± 0.51 mm, and on the left 1.46 ± 0.47 mm (in women 1.44 mm and in men 1.51 mm). The mean of the diameter in the "distal" part (the connection with ICA) on the right side was 1.4 ± 0.49 mm, and on the left 1.37 ± 0.41 mm (in women 1.38 mm, and in men 1.39 mm). No statistical correlation between the length and the diameter of the PCoA in relation to the sex and side was shown. On the basis of our measurements, we defined the hypoplasia of the artery as the estimated value less than the average diameter minus the standard deviation. The percentage distribution was as follows: the left artery 15.5%, the right artery 24%, women 11.5%, and the men 9%. Similarly to the above parameters, we have not found any statistical differences. The presence of the foetal origin was noted in 25% of the radiological examinations. The infundibular widening was visualised in 11.5% of cases of 3D reconstructions. The agenesis of PCoA was found in 9% (never bilaterally), and in 1 case the unilateral duplication of the artery was observed. No statistical differences between those parameters in relation to sex and the examined side were revealed. Morphological calculation of the PCoA on the basis of angio-CT from adult patients did not show any statistical differences depending on sex or the investigated side. The presented method of the calculations proved to be useful for the mathematical definition of the term "hypoplasia of the PCoA".

  18. Three-dimensional analysis of alveolar bone resorption by image processing of 3-D dental CT images

    NASA Astrophysics Data System (ADS)

    Nagao, Jiro; Kitasaka, Takayuki; Mori, Kensaku; Suenaga, Yasuhito; Yamada, Shohzoh; Naitoh, Munetaka

    2006-03-01

    We have developed a novel system that provides total support for assessment of alveolar bone resorption, caused by periodontitis, based on three-dimensional (3-D) dental CT images. In spite of the difficulty in perceiving the complex 3-D shape of resorption, dentists assessing resorption location and severity have been relying on two-dimensional radiography and probing, which merely provides one-dimensional information (depth) about resorption shape. However, there has been little work on assisting assessment of the disease by 3-D image processing and visualization techniques. This work provides quantitative evaluation results and figures for our system that measures the three-dimensional shape and spread of resorption. It has the following functions: (1) measures the depth of resorption by virtually simulating probing in the 3-D CT images, taking advantage of image processing of not suffering obstruction by teeth on the inter-proximal sides and much smaller measurement intervals than the conventional examination; (2) visualizes the disposition of the depth by movies and graphs; (3) produces a quantitative index and intuitive visual representation of the spread of resorption in the inter-radicular region in terms of area; and (4) calculates the volume of resorption as another severity index in the inter-radicular region and the region outside it. Experimental results in two cases of 3-D dental CT images and a comparison of the results with the clinical examination results and experts' measurements of the corresponding patients confirmed that the proposed system gives satisfying results, including 0.1 to 0.6mm of resorption measurement (probing) error and fairly intuitive presentation of measurement and calculation results.

  19. NaCl responsive taste cells in the mouse fungiform taste buds.

    PubMed

    Yoshida, R; Horio, N; Murata, Y; Yasumatsu, K; Shigemura, N; Ninomiya, Y

    2009-03-17

    Previous studies have demonstrated that rodents' chorda tympani (CT) nerve fibers responding to NaCl can be classified according to their sensitivities to the epithelial sodium channel (ENaC) blocker amiloride into two groups: amiloride-sensitive (AS) and -insensitive (AI). The AS fibers were shown to respond specifically to NaCl, whereas AI fibers broadly respond to various electrolytes, including NaCl. These data suggest that salt taste transduction in taste cells may be composed of at least two different systems; AS and AI ones. To further address this issue, we investigated the responses to NaCl, KCl and HCl and the amiloride sensitivity of mouse fungiform papilla taste bud cells which are innervated by the CT nerve. Comparable with the CT data, the results indicated that 56 NaCl-responsive cells tested were classified into two groups; 25 cells ( approximately 44%) narrowly responded to NaCl and their NaCl response were inhibited by amiloride (AS cells), whereas the remaining 31 cells ( approximately 56%) responded not only to NaCl, but to KCl and/or HCl and showed no amiloride inhibition of NaCl responses (AI cells). Amiloride applied to the basolateral side of taste cells had no effect on NaCl responses in the AS and AI cells. Single cell reverse transcription-polymerase chain reaction (RT-PCR) experiments indicated that ENaC subunit mRNA was expressed in a subset of AS cells. These findings suggest that the mouse fungiform taste bud is composed of AS and AI cells that can transmit taste information differently to their corresponding types of CT fibers, and apical ENaCs may be involved in the NaCl responses of AS cells.

  20. 26. Mechanical float gages used to monitor level of water ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. Mechanical float gages used to monitor level of water in the filtration bed reservoir. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  1. 7. Historic American Buildings Survey (Fed.) Stanley P. Mixon, Photographer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Historic American Buildings Survey (Fed.) Stanley P. Mixon, Photographer July 29, 1940 (A) EXTERIOR GENERAL VIEW FROM SOUTH (REAR) SIDE - First Church of Christ (Congregational), Main Street, between School & Church Streets, Farmington, Hartford County, CT

  2. Rapid actions of calcitriol and its side chain analogues CB1093 and GS1500 on intracellular calcium levels in skeletal muscle cells: a comparative study

    PubMed Central

    Vazquez, Guillermo; Sellés, Juana; de Boland, Ana Russo; Boland, Ricardo

    1999-01-01

    The ability of synthetic analogues of the secosteroid hormone 1α,25-dihydroxy-vitamin-D3 [calcitriol, CT; 1,25(OH)2D3] to exert non-genomic (rapid) effects on target cells has been scarcely studied. To evaluate the pharmacological potential of the CT side-chain analogues CB1093 and GS1500, we compared their fast effects on intracellular calcium concentration ([Ca2+]i) in chick skeletal muscle cells with those elicited by the natural hormone.Both analogues, similarly to CT, specifically induced rapid (30–60 s) and sustained rises in [Ca2+]i levels. CB1093 and GS1500 were more potent than the natural hormone at concentrations as low as 10−13 M (4.5 fold stimulation) and 10−12 M (2.5 fold), respectively, whereas higher concentrations (10−9–10−8 M) of CT were more effective than the analogues in elevating [Ca2+]i. Cyclic AMP was markedly increased by both analogues pointing for a role of this messenger in the fast actions of the synthetic compounds.In Ca2+ free medium CT and analogues elicited a transient elevation in [Ca2+]i. The PLC inhibitors U73122 (2 μM) and neomycin (0.5 mM), as well as depletion of intracellular stores with thapsigargin (1 μM), completely prevented CB1093/GS1500-dependent changes in [Ca2+]i suggesting that, similarly to CT, these analogues mobilized Ca2+ from an IP3/thapsigargin-sensitive store.The voltage-dependent calcium channel (VDCC) blocker nifedipine (2 μM) reduced by 50–60% the influx phase of the [Ca2+]i response to CB1093 and GS1500, indicating that VDCC contributed partially to Ca2+ entry. The Ca2+ readdition protocol suggested that analogue-dependent activation of a SOC entry pathway accounted, to the same extent as for CT, for the remaining non-VDCC mediated Ca2+ influx. PMID:10372825

  3. The accessory parotid gland and facial process of the parotid gland on computed tomography

    PubMed Central

    Ahn, Dongbin; Yeo, Chang Ki; Han, Soon Yong

    2017-01-01

    The purpose of this study was to determine the incidence of an anterior extension of the parotid gland, such as an accessory parotid gland (APG) or facial process (FP) and to evaluate its characteristics on computed tomography (CT) scans. We reviewed CT scans of 1,600 parotid glands from 800 patients. An APG on CT was defined as a soft-tissue mass of the same density as the main parotid gland, located at the anterior part of the main parotid gland, and completely separate from the main parotid gland. An FP was defined as a lobe of the parotid gland protruding anteriorly over the anterior edge of the ramus of the mandible on CT and showing continuity with the main gland. The overall incidence rates and characteristics of APGs and FPs were evaluated according to age, sex, and side. The incidence rates of APGs and FPs were 10.2% (163/1,600) and 28.3% (452/1,600), respectively. The mean size of an APG was 15.8 mm × 5.0 mm and the mean distance from the main parotid gland was 10.5 mm. The FP reached anteriorly between the anterior edge of the mandibular ramus and the anterior border of the masseter muscle in 405 (89.6%) cases, while it extended over the anterior border of the masseter muscle in 47 (10.4%) cases. The incidence rates of APGs and FPs decreased and increased, respectively, with increasing age, showing significant linear correlations. However, the incidence of an anterior extension of the parotid gland (either an APG or an FP) was similar across all age groups. The present study showed that CT might be helpful in identifying anterior extensions of the parotid gland including APGs and FPs. The anatomical information gained from this study contributes to a better understanding of APGs and FPs and how their incidence changes with age. PMID:28915265

  4. SU-E-T-317: The Development of a DIBH Technique for Left Sided Breast Patients Undergoing Radiation Therapy Utilizing Varians RPM System in a Community Hospital

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasson, B; Young, M; Workie, D

    2014-06-01

    Purpose: To develop and implement a Deep Inhalation Breath Hold program (DIBH) for treatment of patients with Left-sided breast cancer in a community hospital. Methods: All patients with left sided breast cancer underwent a screening free breathing CT. Evaluation of the conventional tangent treatment fields and the heart was conducted. If the heart would not be excluded using tangents, the patient then received DIBH breathe coaching. The patients returned for a 4D CT simulation. The patients breathing cycle was monitored using the Varian Real-Time position ManagementTM (RPM) system to assess duration of DIBH, amplitude, phase and recovery time to normalmore » breathing. Then a DIBH CT was obtained at the desired amplitude. Duplicate plans were developed for both free breathing and DIBH on the Eclipse planning system and comparison DVH's were created. The plan that provided the prescribed treatment coverage and the least doses to the OAR (heart, Lt. Lung) was determined. Those patients selected to receive treatment with DIBH were set up for treatment, and breathing was monitored using the RPM system. Practice trials were used to confirm that the amplitude, phase and recovery were consistent with findings from simulation. Results: 10 patients have been treated using the DIBH procedure in our clinic. The DIBH patients had an average increase of 80% lung volume on DIBH, decreased lung volume receiving 50% of the dose, and decreases in the V20 dose. Significant reduction in the maximum and mean dose to the heart, as well as the dose to 1CC of the volume for the DIBH plans. Conclusion: Using the RPM system already available in the clinic, staff training, and patient coaching a simple DIBH program was setup. The use of DIBH has shown promise in reducing doses to the critical organs while maintaining PTV coverage for left sided breast treatments.« less

  5. Segmentation and Visual Analysis of Whole-Body Mouse Skeleton microSPECT

    PubMed Central

    Khmelinskii, Artem; Groen, Harald C.; Baiker, Martin; de Jong, Marion; Lelieveldt, Boudewijn P. F.

    2012-01-01

    Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality, postural and positioning variability). The goal of this study was to provide a method to align and compare side-by-side multiple whole-body skeleton SPECT datasets in a common reference, thus eliminating acquisition variability that exists between the subjects in cross-sectional and multi-modal studies. Six whole-body SPECT/CT datasets of BALB/c mice injected with bone targeting tracers 99mTc-methylene diphosphonate (99mTc-MDP) and 99mTc-hydroxymethane diphosphonate (99mTc-HDP) were used to evaluate the proposed method. An articulated version of the MOBY whole-body mouse atlas was used as a common reference. Its individual bones were registered one-by-one to the skeleton extracted from the acquired SPECT data following an anatomical hierarchical tree. Sequential registration was used while constraining the local degrees of freedom (DoFs) of each bone in accordance to the type of joint and its range of motion. The Articulated Planar Reformation (APR) algorithm was applied to the segmented data for side-by-side change visualization and comparison of data. To quantitatively evaluate the proposed algorithm, bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances between each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance decreased from 11.5±12.1 to 2.6±2.1 voxels. The proposed approach yielded satisfactory segmentation results with minimal user intervention. It proved to be robust for “incomplete” data (large chunks of skeleton missing) and for an intuitive exploration and comparison of multi-modal SPECT/CT cross-sectional mouse data. PMID:23152834

  6. Feasibility Study of a Novel Thoraco-abdominal Aortic Hybrid Device (SPIDER-graft) in a Translational Pig Model.

    PubMed

    Debus, Eike S; Kölbel, Tilo; Duprée, Anna; Daum, Günter; Sandhu, Harleen K; Manzoni, Daniel; Wipper, Sabine H

    2018-02-01

    The hybrid SPIDER-graft consists of a proximal descending aortic stent graft and a conventional six branched Dacron graft for open abdominal aortic repair. Technical feasibility with regard to avoiding thoracotomy and extracorporeal circulation (ECC) during thoraco-abdominal aortic hybrid repair and peri-procedural safety of this novel device are unknown. This was a feasibility and safety study in domestic pigs (75-85 kg). The abdominal aorta including iliac bifurcation, left renal artery, and visceral arteries were exposed via retroperitoneal access. The right iliac branch was first temporarily anastomosed end to side to the distal aorta via partial clamping. During inflow reduction and infra-coeliac cross-clamping, the coeliac trunk (CT) was divided and the proximal stent graft portion of the SPIDER-graft was deployed into the descending aorta via the CT ostium. Retrograde visceral and antegrade aorto-iliac blood flow was maintained via the iliac side branch. The visceral, renal, and iliac arteries were sequentially anastomosed, finally replacing the first iliac end to side anastomosis. Technical success, blood flow, periods of ischaemia, and peri-procedural complications were evaluated after intra-operative completion angiography and post-operative computed tomography angiography. Six animals underwent successful thoracic stent graft deployment and distal open reconstruction without peri-operative death. The median thoracic graft implantation time was 4.5 min, and the median ischaemia times before reperfusion were 10 min for the CT, 8 min for the superior mesenteric artery, 13 min for the right renal artery, and 22 min for the left renal artery. Angiography demonstrated appropriate graft implantation and blood flow measurements confirmed sufficient blood flow through all side branches. In this translational pig model, thoraco-abdominal hybrid repair using the novel SPIDER-graft was successful in avoiding thoracotomy and ECC. Technical feasibility and safety appear promising, but need to be reassessed in humans. Copyright © 2017. Published by Elsevier Ltd.

  7. Preoperative 4D CT Localization of Nonlocalizing Parathyroid Adenomas by Ultrasound and SPECT-CT.

    PubMed

    Hinson, Andrew M; Lee, David R; Hobbs, Bradley A; Fitzgerald, Ryan T; Bodenner, Donald L; Stack, Brendan C

    2015-11-01

    To evaluate 4-dimensional (4D) computed tomography (CT) for the localization of parathyroid adenomas previously considered nonlocalizing on ultrasound and single-photon emission CT with CT scanning (SPECT-CT). To measure radiation exposure associated with 4D-CT and compared it with SPECT-CT. Case series with chart review. University tertiary hospital. Nineteen adults with primary hyperparathyroidism who underwent preoperative 4D CT from November 2013 through July 2014 after nonlocalizing preoperative ultrasound and technetium-99m SPECT-CT scans. Sensitivity, specificity, predictive values, and accuracy of 4D CT were evaluated. Nineteen patients (16 women and 3 men) were included with a mean age of 66 years (range, 39-80 years). Mean preoperative parathyroid hormone level was 108.5 pg/mL (range, 59.3-220.9 pg/mL), and mean weight of the excised gland was 350 mg (range, 83-797 mg). 4D CT sensitivity and specificity for localization to the patient's correct side of the neck were 84.2% and 81.8%, respectively; accuracy was 82.9%. The sensitivity for localizing adenomas to the correct quadrant was 76.5% and 91.5%, respectively; accuracy was 88.2%. 4D CT radiation exposure was significantly less than the radiation associated with SPECT-CT (13.8 vs 18.4 mSv, P = 0.04). 4D CT localizes parathyroid adenomas with relatively high sensitivity and specificity and allows for the localization of some adenomas not observed on other sestamibi-based scans. 4D CT was also associated with less radiation exposure when compared with SPECT-CT based on our study protocol. 4D CT may be considered as first- or second-line imaging for localizing parathyroid adenomas in the setting of primary hyperparathyroidism. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  8. Recurrent spontaneous massive hemothorax from intrathoracic extramedullary hematopoiesis resulting in respiratory failure.

    PubMed

    Chu, Kuo-An; Hsu, Chien-Wei; Lin, Min-Hsi; Lin, Shyh-Jer; Huang, Yi-Luan

    2015-03-01

    Extramedullary hematopoiesis (EMH) is a compensatory response to many chronic anemic disorders. Intrathoracic EMH, usually presenting as paravertebral masses over the posterior mediastinum, is a rare entity and is usually asymptomatic. Hemothorax is a rare but possibly fatal complication. Local radiation for intrathoracic EMH is considered effective in preventing its recurrence. Here we describe a patient who had had α-thalassemia for many years and developed a spontaneous left-sided hemothorax from EMH. A chest film and a chest computed tomography (CT) scan had showed multiple paravertebral masses over the lower thoracic spine with left-sided pleural effusion. A pathological diagnosis of EMH was made by video-assisted thoracoscopic surgery. The patient had not received preventive local chest radiation. Ten years later, he suffered from a life-threatening hemothorax complicated by acute respiratory failure without traumatic history. A CT scan showed posterior mediastinal masses over the lower thoracic spine with right-sided pleural effusion. Thoracoscopy was performed to remove the blood clot in the pleural space for successful weaning from mechanical ventilation. This is the first case of intrathoracic EMH to have recurrent hemothorax associated with acute respiratory failure. Copyright © 2012. Published by Elsevier B.V.

  9. Ultrasound guided fluorescence molecular tomography with improved quantification by an attenuation compensated born-normalization and in vivo preclinical study of cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Baoqiang; Berti, Romain; Abran, Maxime

    2014-05-15

    Ultrasound imaging, having the advantages of low-cost and non-invasiveness over MRI and X-ray CT, was reported by several studies as an adequate complement to fluorescence molecular tomography with the perspective of improving localization and quantification of fluorescent molecular targets in vivo. Based on the previous work, an improved dual-modality Fluorescence-Ultrasound imaging system was developed and then validated in imaging study with preclinical tumor model. Ultrasound imaging and a profilometer were used to obtain the anatomical prior information and 3D surface, separately, to precisely extract the tissue boundary on both sides of sample in order to achieve improved fluorescence reconstruction. Furthermore,more » a pattern-based fluorescence reconstruction on the detection side was incorporated to enable dimensional reduction of the dataset while keeping the useful information for reconstruction. Due to its putative role in the current imaging geometry and the chosen reconstruction technique, we developed an attenuation compensated Born-normalization method to reduce the attenuation effects and cancel off experimental factors when collecting quantitative fluorescence datasets over large area. Results of both simulation and phantom study demonstrated that fluorescent targets could be recovered accurately and quantitatively using this reconstruction mechanism. Finally, in vivo experiment confirms that the imaging system associated with the proposed image reconstruction approach was able to extract both functional and anatomical information, thereby improving quantification and localization of molecular targets.« less

  10. Multi-layer cube sampling for liver boundary detection in PET-CT images.

    PubMed

    Liu, Xinxin; Yang, Jian; Song, Shuang; Song, Hong; Ai, Danni; Zhu, Jianjun; Jiang, Yurong; Wang, Yongtian

    2018-06-01

    Liver metabolic information is considered as a crucial diagnostic marker for the diagnosis of fever of unknown origin, and liver recognition is the basis of automatic diagnosis of metabolic information extraction. However, the poor quality of PET and CT images is a challenge for information extraction and target recognition in PET-CT images. The existing detection method cannot meet the requirement of liver recognition in PET-CT images, which is the key problem in the big data analysis of PET-CT images. A novel texture feature descriptor called multi-layer cube sampling (MLCS) is developed for liver boundary detection in low-dose CT and PET images. The cube sampling feature is proposed for extracting more texture information, which uses a bi-centric voxel strategy. Neighbour voxels are divided into three regions by the centre voxel and the reference voxel in the histogram, and the voxel distribution information is statistically classified as texture feature. Multi-layer texture features are also used to improve the ability and adaptability of target recognition in volume data. The proposed feature is tested on the PET and CT images for liver boundary detection. For the liver in the volume data, mean detection rate (DR) and mean error rate (ER) reached 95.15 and 7.81% in low-quality PET images, and 83.10 and 21.08% in low-contrast CT images. The experimental results demonstrated that the proposed method is effective and robust for liver boundary detection.

  11. No Side-to-Side Difference in Humeral Retroversion in Baseball Players with Shoulder Disorders Using a True Three-Dimensional Measurement Technique: Validation and Comparison

    PubMed Central

    Saka, Masayuki; Yamauchi, Hiroki; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi

    2014-01-01

    Objectives: Increased humeral retroversion in the throwing shoulder is considered to exist in many baseball players and is often considered as a cause of internal rotation deficit. However, retroversion angles using two-dimensional (2D) methods utilized in previous studies did not correlated with a true three-dimensional measurement technique (3D retroversion) in our study. The purposes of this study were to determine 1) if significant side-to-side differences in retroversion exist, and 2) the relationships between retroversion and glenohumeral range of motion (ROM) in baseball players with a shoulder disorder. Methods: Fourteen male baseball players (age: 21.4 ± 1.5 years; mean ± standard deviation) with a throwing shoulder disorder were enrolled, including 11 in the collegiate and 3 in the adult levels, comprising 5 pitchers and 9 position players. The mean age when the athletes had started playing baseball was 9.1 years (range, 6 to 10 years) and the mean playing experience was 12.1 years (range, 9 to 17 years). Patients with history of fracture or surgery in the shoulder or elbow were excluded. Outcome measurements included a 3D retroversion angle and glenohumeral ROM in bilateral shoulders. Patients underwent CT scan at 1.0 mm slice pitch for the bilateral humerus and geometric bone models were created. The 3D retroversion angle was defined as an angle between the projected humeral neck line (connecting the spherical center of the humeral head and the cylindrical axis of the humeral shaft) onto the horizontal plane and the flexion-extension axis of the distal humerus obtained by a cylinder-fitting method for the capitulum and trochlea (intratester reliability: ICC 0.98, standard error of measurement: 1.7º). The CT slices for the proximal and distal humerus were used to measure a 2D-CT retroversion angle using a reported convention. An indirect measurement of retroversion was performed using a bicipital grove-ulna angle by an ultrasound images dusing a reported convention. Glenohumeral ROM measurements included internal rotation (IR) and horizontal adduction (HAd) in the supine position with the scapula manually stabilized on the treatment table. Independent t tests were used to determine if significant side-to-side differences exist in retroversion and glenohumeral ROM. Pearson correlation coefficients were used to determine the association between retroversion and glenohumeral ROM in the throwing shoulders. Statistical analysis was performed with PASW Statistics 18 (SPSS, Inc, Chicago, IL). An alpha level of 0.05 was set a priori for statistical significance. Results: No significant difference was found in 3D retroversion between the throwing and non-throwing shoulders (P = .182). The throwing shoulders demonstrated decreased IR and HAd compared with the non-throwing shoulders (P < .001 and P = .002, respectively). There were no significant correlations between retroversion and glenohumeral ROM for the throwing shoulders (Table). The 2D-CT retroversion and bicipital grove-ulna angles were greater in the throwing shoulder (P = .007 and .009, respectively). Conclusion: Contradicted to the previous studies, no side-to-side difference in retroversion and no association between retroversion and glenohumeral ROM were observed in the baseball players with a shoulder disorder. We believe that deficit in shoulder IR and HAd may be attributed to soft tissue tightness. The results of the previous studies involving humeral retroversion should be reassessed.

  12. Effect of clinical decision rules, patient cost and malpractice information on clinician brain CT image ordering: a randomized controlled trial.

    PubMed

    Gimbel, Ronald W; Pirrallo, Ronald G; Lowe, Steven C; Wright, David W; Zhang, Lu; Woo, Min-Jae; Fontelo, Paul; Liu, Fang; Connor, Zachary

    2018-03-12

    The frequency of head computed tomography (CT) imaging for mild head trauma patients has raised safety and cost concerns. Validated clinical decision rules exist in the published literature and on-line sources to guide medical image ordering but are often not used by emergency department (ED) clinicians. Using simulation, we explored whether the presentation of a clinical decision rule (i.e. Canadian CT Head Rule - CCHR), findings from malpractice cases related to clinicians not ordering CT imaging in mild head trauma cases, and estimated patient out-of-pocket cost might influence clinician brain CT ordering. Understanding what type and how information may influence clinical decision making in the ordering advanced medical imaging is important in shaping the optimal design and implementation of related clinical decision support systems. Multi-center, double-blinded simulation-based randomized controlled trial. Following standardized clinical vignette presentation, clinicians made an initial imaging decision for the patient. This was followed by additional information on decision support rules, malpractice outcome review, and patient cost; each with opportunity to modify their initial order. The malpractice and cost information differed by assigned group to test the any temporal relationship. The simulation closed with a second vignette and an imaging decision. One hundred sixteen of the 167 participants (66.9%) initially ordered a brain CT scan. After CCHR presentation, the number of clinicians ordering a CT dropped to 76 (45.8%), representing a 21.1% reduction in CT ordering (P = 0.002). This reduction in CT ordering was maintained, in comparison to initial imaging orders, when presented with malpractice review information (p = 0.002) and patient cost information (p = 0.002). About 57% of clinicians changed their order during study, while 43% never modified their imaging order. This study suggests that ED clinician brain CT imaging decisions may be influenced by clinical decision support rules, patient out-of-pocket cost information and findings from malpractice case review. NCT03449862 , February 27, 2018, Retrospectively registered.

  13. Technical Note: Development and validation of an open data format for CT projection data.

    PubMed

    Chen, Baiyu; Duan, Xinhui; Yu, Zhicong; Leng, Shuai; Yu, Lifeng; McCollough, Cynthia

    2015-12-01

    Lack of access to projection data from patient CT scans is a major limitation for development and validation of new reconstruction algorithms. To meet this critical need, this work developed and validated a vendor-neutral format for CT projection data, which will further be employed to build a library of patient projection data for public access. A digital imaging and communication in medicine (DICOM)-like format was created for CT projection data (CT-PD), named the DICOM-CT-PD format. The format stores attenuation information in the DICOM image data block and stores parameters necessary for reconstruction in the DICOM header under various tags (51 tags to store the geometry and scan parameters and 9 tags to store patient information). To validate the accuracy and completeness of the new format, CT projection data from helical scans of the ACR CT accreditation phantom were acquired from two clinical CT scanners (Somatom Definition Flash, Siemens Healthcare, Forchheim, Germany and Discovery CT750 HD, GE Healthcare, Waukesha, WI). After decoding (by the authors for Siemens, by the manufacturer for GE), the projection data were converted to the DICOM-CT-PD format. Off-line CT reconstructions were performed by internal and external reconstruction researchers using only the information stored in the DICOM-CT-PD files and the DICOM-CT-PD field definitions. Compared with the commercially reconstructed CT images, the off-line reconstructed images created using the DICOM-CT-PD format are similar in terms of CT numbers (differences of 5 HU for the bone insert and -9 HU for the air insert), image noise (±1 HU), and low contrast detectability (6 mm rods visible in both). Because of different reconstruction approaches, slightly different in-plane and cross-plane high contrast spatial resolution were obtained compared to those reconstructed on the scanners (axial plane: GE off-line, 7 lp/cm; GE commercial, 7 lp/cm; Siemens off-line, 8 lp/cm; Siemens commercial, 7 lp/cm. Coronal plane: Siemens off-line, 6 lp/cm; Siemens commercial, 8 lp/cm). A vendor-neutral extended DICOM format has been developed that enables open sharing of CT projection data from third-generation CT scanners. Validation of the format showed that the geometric parameters and attenuation information in the DICOM-CT-PD file were correctly stored, could be retrieved with use of the provided instructions, and contained sufficient data for reconstruction of CT images that approximated those from the commercial scanner.

  14. Imaging diagnosis--temporomandibular joint dysplasia in a Basset Hound.

    PubMed

    Lerer, Assaf; Chalmers, Heather J; Moens, Noel M M; Mackenzie, Shawn D; Kry, Kristin

    2014-01-01

    A 5-month-old intact male Basset Hound presented for evaluation of pain and crepitation during manipulation of the temporomandibular joint, worse on the right side. A computed tomography (CT) scan of the head was performed. The CT images demonstrated the osseous features of temporomandibular joint dysplasia and facilitated a 3D reconstruction, which allowed better visualization of the dysplastic features. The patient responded to conservative management with a tape muzzle with no recurrence reported by the owner 6 months after presentation. © 2013 American College of Veterinary Radiology.

  15. TU-F-17A-06: Motion Stability and Dosimetric Impact of Spirometer-Based DIBH-RT of Left-Sided Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKenzie, E; Yang, W; Burnison, M

    2014-06-15

    Purpose: Patients undergoing radiotherapy (RT) for left-sided breast cancer have increased risk of coronary artery disease. Deep Inhalation Breath Hold assisted RT (DIBH-RT) is shown to increase the geometric separation of the target area and heart, reducing cardiac radiation dose. The purposes of this study are to use Cine MV portal images to determine the stability of spirometer-guided DIBH-RT and examine the dosimetric cardiopulmonary impact of this technique. Methods: Twenty consecutive patients with left-sided breast cancer were recruited to the IRB-approved study. Free-breathing (FB) and DIBH-CT's were acquired at simulation. Rigid registration of the FB-CT and DIBH-CT was performed usingmore » primarily breast tissue. Treatment plans were created for each FB-CT and DIBH-CT using identical paired tangent fields with field-in-field or electronic compensation techniques. Dosimetric evaluation included mean and maximum (Dmax) doses for the left anterior descending artery (LAD), mean heart dose, and left lung V20. Cine MV portal images were acquired for medial and lateral fields during treatment. Analysis of Cine images involved chest wall segmentation using an algorithm developed in-house. Intra- and inter-fractional chest wall motion were determined through affine registration to the first frame of each Cine. Results: Dose to each cardiac structure evaluated was significantly (p<0.001) reduced with the DIBH plans. Mean heart dose decreased from 2.9(0.9–6.6) to 1.6(0.6–5.3) Gy; mean LAD dose from 16.6(3–43.6) to 7.4(1.7–32.7) Gy; and LAD Dmax from 35.4 (6.1–53) to 18.4(2.5–51.2) Gy. No statistically significant reduction was found for the left lung V20. Average AP and SI median chest wall motion (intrafractional) was 0.1 (SD=0.9) and 0.5 (SD=1.1) mm, respectively. Average AP inter-fractional chest wall motion was 2.0 (SD=1.4) mm. Conclusion: Spirometer-based DIBH treatments of the left breast are reproducible both inter- and intra-fractionally, and provide a statistically and potentially clinically useful dosimetric advantage to cardiac structures.« less

  16. Posterolateral lumbar fusion using Escherichia coli-derived rhBMP-2/hydroxyapatite in the mini pig.

    PubMed

    Kong, Chang-Bae; Lee, Jae Hyup; Baek, Hae-Ri; Lee, Choon-Ki; Chang, Bong-Soon

    2014-12-01

    Hydroxyapatite (HA) is used as a bone graft extender for posterolateral spinal fusion in human. It is also useful as a recombinant human bone morphogenetic protein (rhBMP)-2 carrier because of its high affinity for rhBMP-2. To assess the osteoinductivity of Escherichia coli-derived rhBMP-2 (E-BMP-2) using HA granules as a carrier and to evaluate the bone-forming ability depending on the different dosages of E-BMP-2. A mini-pig lumbar posterolateral fusion model using microcomputed tomography (μCT) scanning. Thirty-one adult male mini pigs were randomized into a single control group (n=8) without E-BMP-2 and two experimental groups with two different doses of E-BMP-2 (1 mg per side, n=8 and 3 mg per side, n=15). Outcome was measured by plain radiography, manual palpation, CT, three-dimensional μCT, and histologic examinations. Bilateral intertransverse process arthrodesis was performed, and E-BMP-2 (0, 1.0, 3.0 mg per side) was implanted into the intertransverse space using HA granules as a carrier. Three mini pigs were removed because of death. Among 28 experimental subjects, 19 animals achieved solid bony union. The fusion rates were 37.5% for control group, 71.4% for 1 mg group, and 84.6% for 3 mg group. Fusion rates were significantly different among groups (p=.031). However, there was no statistically significant difference in fusion rates between 1 and 3 mg groups (p=.587). Thirty-eight intertransverse fusion masses of 19 subjects underwent μCT scanning. The bone volumes determined by μCT were 12,603±3,240 mm(3) for control group, 18,718±3,000 mm(3) for 1 mg group, and 26,768±7,256 mm(3) for 3 mg group, and the difference between groups was statistically significant (p<.001). This study shows that E-BMP-2 has osteoinductive activity in dose-dependent fashion, and porous HA granule is suitable for E-BMP-2 carrier in a porcine posterolateral fusion model. These preliminary findings suggest that E-BMP-2-adsorbed porous HA granules could be a novel effective bone graft substitute. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Wake-Up Right-Sided Hemiparesis and Dysarthria in a Heavy Snorer.

    PubMed

    Brunetti, Valerio; Ferilli, Michela Ada Noris; Vollono, Catello; Di Franco, Antonino; Della Marca, Giacomo

    2018-01-01

    A 57-year-old man was referred to the ED for wake-up right-sided hemiparesis, hypoesthesia, dysarthria, and a National Institutes of Health Stroke Scale score of 7. Urgent CT brain scanning showed an ischemic lesion of the left temporal and insular lobes. The patient was admitted to the stroke unit, and acetylsalicylic acid 300 mg and low-molecular-weight heparin 6,000 IU were administered. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  18. The evaluation of complex clinical trial protocols: resources available to research ethics committees and the use of clinical trial registries--a case study.

    PubMed

    Homedes, Núria; Ugalde, Antonio

    2015-06-01

    To assess the potential role of clinical trial (CT) registries and other resources available to research ethics committees (RECs) in the evaluation of complex CT protocols in low-income and middle-income countries. Using a case study approach, the authors examined the decision-making process of a REC in Argentina and its efforts to use available resources to decide on a complex protocol. We also analysed the information in the USA and other CT registries and consulted 24 CT experts in seven countries. Information requested by the Argentinean REC from other national RECs and ethics' experts was not useful to verify the adequacy of the REC's decision whether or not to approve the CT. The responses from the national regulatory agency and the sponsor were not helpful either. The identification of international resources that could assist was beyond the REC's capability. The information in the USA and other CT registries is limited, and at times misleading; and its accuracy is not verified by register keepers. RECs have limited access to experts and institutions that could assist them in their deliberations. Sponsors do not always answer RECs' request for information to properly conduct the ethical and methodological assessment of CT protocols. The usefulness of the CT registries is curtailed by the lack of appropriate codes and by data errors. Information about reasons for rejection, withdrawal or suspension of the trial should be included in the registries. Establishing formal channels of communication among national and foreign RECs and with independent international reference centres could strengthen the ethical review of CT protocols. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Preoperative computed tomography diagnosis of non-recurrent laryngeal nerve in patients with esophageal carcinoma.

    PubMed

    Niu, Zhong-Xi; Zhang, Hang; Chen, Long-Qi; Shi, Hui; Peng, Jun; Su, Li-Wei; Li, Wei; Xiao, Bo; He, Shu; Yue, Hong-Xu

    2017-01-01

    The non-recurrent laryngeal nerve (NRLN) is a rare but potentially serious anomaly that is commonly associated with the aberrant right subclavian artery (ARSA). It is easy to damage during surgical resection of esophageal cancer, leading to severe complications. Preoperative enhanced thoracic computed tomography (CT) scans of 2697 patients with esophageal carcinoma treated in our hospital between January 2010 and December 2013 were examined. We classified the positional relationship between the right subclavian artery and the membranous wall of the trachea into two types and used this method to predicate NRLN by identifying ARSA. Twenty-six patients (0.96%) were identified with ARSA, all of which were cases of NRLN by CT. NRLN was identified during surgery in the 26 patients, and a normal right recurrent laryngeal nerve was observed in 2671 patients. The ARSA was detected on the dorsal side of the membranous wall of the trachea in all 26 NRLN cases, while it was detected on the ventral side in all 2671 recurrent laryngeal nerve cases. Enhanced CT scanning is a reliable method for predicting NRLN by identifying ARSA. Preoperative recognition of this nerve anomaly allows surgeons to avoid damaging the nerve and abnormal vessels during esophagectomy. © 2016 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  20. Quantitative measurement of radiofrequency volumetric tissue reduction by multidetector CT in patients with inferior turbinate hypertrophy.

    PubMed

    Bahadir, Osman; Kosucu, Polat

    2012-12-01

    To objectively assess the efficacy of radiofrequency thermal ablation of inferior turbinate hypertrophy. Thirty-five patients with nasal obstruction secondary to inferior turbinate hypertrophy were prospectively enrolled. Radiofrequency energy was delivered to four sites in each inferior turbinate. Patients were evaluated before and 8 weeks after intervention. Subjective evaluation of nasal obstruction was performed using a visual analogue scale (VAS), and objective evaluation of the turbinate volume reduction was calculated using multidetector CT. Volumetric measurements of the preoperative inferior turbinate were compared with postoperative values on both sides. The great majority of patients (91.4%) exhibited subjective postoperative improvement. Mean obstruction (VAS) improved significantly from 7.45±1.48 to 3.54±1.96. Significant turbinate volume reduction was achieved by the surgery on both right and left sides [(preoperative vs. postoperative, right: 6.55±1.62cm(3) vs. 5.10±1.47cm(3), (P<0.01); left: 6.72±1.53cm(3) vs. 5.00±1.37cm(3), (P<0.01)] respectively. Radiofrequency is a safe and effective surgical procedure in reducing turbinate volume in patients with inferior turbinate hypertrophy. Multidetector CT is an objective method of assessment in detecting radiofrequency turbinate volume reduction. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Optimal Co-segmentation of Tumor in PET-CT Images with Context Information

    PubMed Central

    Song, Qi; Bai, Junjie; Han, Dongfeng; Bhatia, Sudershan; Sun, Wenqing; Rockey, William; Bayouth, John E.; Buatti, John M.

    2014-01-01

    PET-CT images have been widely used in clinical practice for radiotherapy treatment planning of the radiotherapy. Many existing segmentation approaches only work for a single imaging modality, which suffer from the low spatial resolution in PET or low contrast in CT. In this work we propose a novel method for the co-segmentation of the tumor in both PET and CT images, which makes use of advantages from each modality: the functionality information from PET and the anatomical structure information from CT. The approach formulates the segmentation problem as a minimization problem of a Markov Random Field (MRF) model, which encodes the information from both modalities. The optimization is solved using a graph-cut based method. Two sub-graphs are constructed for the segmentation of the PET and the CT images, respectively. To achieve consistent results in two modalities, an adaptive context cost is enforced by adding context arcs between the two subgraphs. An optimal solution can be obtained by solving a single maximum flow problem, which leads to simultaneous segmentation of the tumor volumes in both modalities. The proposed algorithm was validated in robust delineation of lung tumors on 23 PET-CT datasets and two head-and-neck cancer subjects. Both qualitative and quantitative results show significant improvement compared to the graph cut methods solely using PET or CT. PMID:23693127

  2. Naturally acquired bovine besnoitiosis: Differential distribution of parasites in the skin of chronically infected cattle.

    PubMed

    Schares, G; Langenmayer, M C; Majzoub-Altweck, M; Scharr, J C; Gentile, A; Maksimov, A; Schares, S; Conraths, F J; Gollnick, N S

    2016-01-30

    Bovine besnoitiosis is caused by Besnoitia besnoiti, an apicomplexan parasite closely related to Toxoplasma gondii and Neospora caninum. In the acute stage of besnoitiosis, cattle suffer from pyrexia, swollen lymph nodes, anorexia and subcutaneous edema. In the chronic stage, tissue cysts are formed in a variety of tissues including the skin. Knowledge about the distribution of tissue cysts of different parts of the skin of infected animals is scarce. Four chronically infected cattle were euthanized and skin samples were taken from a total of 77 standardized cutaneous locations per animal. Portions of the dermis were taken, from which DNA was extracted and examined by real-time PCR. Cycle of transition (Ct) values reflecting the amount of parasite DNA in the samples were determined. For statistical analysis, samples were attributed to 11 larger skin regions ('OuterHindlegDistal', 'Rump, ForelegMiddle', 'NoseFrontEars', 'CheekEye', 'SideLowerPart', 'ForelegDistal', 'SideUpperPart', 'LegsInner', 'VentralHeadNeck', 'DorsalNeckWithersBackTail'). While all samples revealed a positive result in three female cattle, only 63.6% (49/77) of the samples of a bull showed positive results. For statistical analysis, a Ct value of 45 was assumed for samples with a negative result. The dams showed median Ct values of 16.1, 17.5 and 19.4, while in skin samples of the bull a median Ct value of 37.6 was observed. To determine the differences in DNA concentrations between different locations of the skin of the animals, a relative Ct (relCt) was determined by subtracting for each animal indv the MedianCtindv from each sample Ct. Analyses of the relCt values showed that the highest relative parasite DNA concentrations were observed in the categories 'OuterHindlegDistal', 'Rump', 'ForelegMiddle' and 'NoseFrontEars'. The relCt values in these categories differed statistically significantly from those determined for the categories 'VentralHeadNeck' and 'DorsalNeckWithersBackTail'. The analysis showed clear differences in the distribution and the detectability of parasite DNA in the skin of cattle infected with B. besnoiti. In all four animals, samples from the 'Rump' region (Regio fermoris) showed high parasite DNA concentrations. Because this region is also easily accessible for veterinarians, this skin location appears to be optimal for taking skin biopsies for detection or isolation of B. besnoiti. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Evaluation of radiographic, computed tomographic, and cadaveric anatomy of the head of boa constrictors.

    PubMed

    Banzato, Tommaso; Russo, Elisa; Di Toma, Anna; Palmisano, Giuseppe; Zotti, Alessandro

    2011-12-01

    To evaluate the radiographic, computed tomographic (CT), and cadaveric anatomy of the head of boa constrictors. 4 Boa constrictor imperator cadavers. Cadavers weighed 3.4 to 5.6 kg and had a body length ranging from 189 to 221 cm. Radiographic and CT images were obtained with a high-detail screen-film combination, and conventional CT was performed with a slice thickness of 1.5 mm. Radiographic images were obtained in ventrodorsal, dorsoventral, and left and right laterolateral recumbency; CT images were obtained with the animals positioned in ventral recumbency directly laying on a plastic support. At the end of the radiographic and CT imaging session, 2 heads were sectioned following a stratigraphic approach; the other 2, carefully maintained in the same position on the plastic support, were moved into a freezer (-20°C) until completely frozen and then sectioned into 3-mm slices, respecting the imaging protocol. The frozen sections were cleaned and then photographed on each side. Anatomic structures were identified and labeled on gross anatomic images and on the corresponding CT or radiographic image with the aid of available literature. Radiographic and CT images provided high detail for visualization of bony structures; soft tissues were not easily identified on radiographic and CT images. Results provide an atlas of stratigraphic and cross-sectional gross anatomy and radiographic and CT anatomy of the heads of boa constrictors that might be useful in the interpretation of any imaging modality in this species.

  4. An evaluation on CT image acquisition method for medical VR applications

    NASA Astrophysics Data System (ADS)

    Jang, Seong-wook; Ko, Junho; Yoo, Yon-sik; Kim, Yoonsang

    2017-02-01

    Recent medical virtual reality (VR) applications to minimize re-operations are being studied for improvements in surgical efficiency and reduction of operation error. The CT image acquisition method considering three-dimensional (3D) modeling for medical VR applications is important, because the realistic model is required for the actual human organ. However, the research for medical VR applications has focused on 3D modeling techniques and utilized 3D models. In addition, research on a CT image acquisition method considering 3D modeling has never been reported. The conventional CT image acquisition method involves scanning a limited area of the lesion for the diagnosis of doctors once or twice. However, the medical VR application is required to acquire the CT image considering patients' various postures and a wider area than the lesion. A wider area than the lesion is required because of the necessary process of comparing bilateral sides for dyskinesia diagnosis of the shoulder, pelvis, and leg. Moreover, patients' various postures are required due to the different effects on the musculoskeletal system. Therefore, in this paper, we perform a comparative experiment on the acquired CT images considering image area (unilateral/bilateral) and patients' postures (neutral/abducted). CT images are acquired from 10 patients for the experiments, and the acquired CT images are evaluated based on the length per pixel and the morphological deviation. Finally, by comparing the experiment results, we evaluate the CT image acquisition method for medical VR applications.

  5. 22. VIEW OF ESCAPE TRAINING TANK, LOOKING WEST FROM EAST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. VIEW OF ESCAPE TRAINING TANK, LOOKING WEST FROM EAST SIDE OF CUPOLA TOWARD ELEVATOR. TWO-LOCK RECOMPRESSION CHAMBER AT REAR - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  6. 4. Historic American Buildings Survey (Fed.) Stanley P. Mixon, Photographer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Historic American Buildings Survey (Fed.) Stanley P. Mixon, Photographer May 16, 1940 (A) EXTERIOR, GENERAL VIEW EAST (TOWER) END AND SOUTH SIDE. (Belfry & Spire have been rebuilt since Hurricane of Sept 21, 1938) - Unitarian Church, Brooklyn, Windham County, CT

  7. 1. Perspective view southwest of filtration bed with earth mounded ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Perspective view southwest of filtration bed with earth mounded over facility. Armory Street appears in the foreground. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richer, Jeff; Frimeth, Jeff; Nesbitt, James

    Purpose: In Ontario, shielding for all X-ray machines, including CT scanners, must be evaluated according to Safety Code 20A (Health Canada, 1983) which is based on NCRP-49 (NCRP, 1976). NCRP-147 (NCRP, 2004) is the international standard for shielding calculations of CT scanners and is also referenced in Safety Code 35 (Health Canada, 2008) which, was published to supersede SC20A. The goal of this work is to demonstrate the cost effectiveness of NCRP-147 for CT scanner shielding. Methods: CT scanner shielding calculations are performed using SC20A and NCRP-147: A room located on the third floor with the nearest building 75m awaymore » A room with high occupancy uncontrolled adjacent spaces Two side by side rooms on the main floor Results: 1. SC20A: The exterior windows required 0.1mm of Pb to protect the public who may occupy the building at 75m. 1. NCRP-147: No additional shielding required. 2. SC20A: Two walls adjacent to high occupancy uncontrolled space required an additional 1.58mm Pb. 2. NCRP-147: No additional shielding required. 3. SC20A: The entire floor and ceiling slabs in both rooms required an additional 0.79mm Pb. In addition, 0.79mm Pb was added to the walls from the ceiling to overlap the existing Pb shielding in the walls. 3. NCRP-147: No additional shielding required. Conclusion: The application of NCRP Report No. 147 affords the required protection to staff and the public, in the true spirit of the ALARA principle, taking into account relevant social and economic factors.« less

  9. Assessment of image quality in soft tissue and bone visualization tasks for a dedicated extremity cone-beam CT system.

    PubMed

    Demehri, S; Muhit, A; Zbijewski, W; Stayman, J W; Yorkston, J; Packard, N; Senn, R; Yang, D; Foos, D; Thawait, G K; Fayad, L M; Chhabra, A; Carrino, J A; Siewerdsen, J H

    2015-06-01

    To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80 kVp-108mAs for CBCT; 120 kVp- 300 mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal-Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Knee CBCT images were rated "excellent" or "good" (median scores 5 and 4) for "bone" and "soft tissue" visualization tasks. Hand CBCT images were rated "excellent" or "adequate" (median scores 5 and 3) for "bone" and "soft tissue" visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ~ 0.26-0.92), and interobserver agreement was fair to moderate (κ ~ 0.27-0.54). CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. • CBCT provided adequate image quality for diagnostic tasks in extremity imaging. • CBCT images were "excellent" for "bone" and "good/adequate" for "soft tissue" visualization tasks. • CBCT image quality was equivalent/superior to MDCT for bone visualization tasks.

  10. Pituitary Imaging.

    PubMed

    Pressman, Barry D

    2017-09-01

    Modern pituitary imaging is MRI. However, computed tomography (CT) still has limited usefulness. In addition, because CT offers much better bone detail and calcium detection, there are some cases in which such additional information is necessary. Before the advent of CT, plain radiography, pneumoencephalography, and angiography were used to diagnose pituitary masses. More recently, CT, and then especially MRI, made it possible to primarily delineate lesions within and around the pituitary gland rather than depend on secondary information that could only suggest their presence. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Recurrent Temporal Bone Tenosynovial Giant Cell Tumor with Chondroid Metaplasia: the Use of Imaging to Assess Recurrence

    PubMed Central

    Pina, Sofia; Fernandez, Maria; Maya, Silvia; Garcia, Roberto A.; Noor, Ali; Pawha, Puneet S.; Som, Peter M.

    2014-01-01

    Summary Tenosynovial giant cell tumor (TGCT) is a benign proliferative lesion of unclear etiology. It is predominantly monoarticular and involves the synovium of the joint, tendon sheath, and bursa. TGCT of the temporomandibular joint (TMJ) is rare and aggressive resulting in destruction of surrounding structures. The diagnosis may be suggested by imaging, mainly by the MR features and PET/CT, and confirmed by histopathology. We describe the case of a 50-year-old man who presented with right-sided hearing loss, tinnitus and TMJ pain. Pathology revealed tenosynovial giant cell tumor with chondroid metaplasia. Six years later he developed a recurrence, which was documented to our knowledge for the first time with CT, MR and FDG PET/CT imaging. PMID:24571839

  12. Pleural mesothelioma - case report.

    PubMed

    Klawiter, Anna; Damaszke, Tomasz

    2010-10-01

    Pleural mesothelioma is a very rare neoplasm; especially the local form. The diagnostics is difficult and the prognosis unfavourable. We presented a case of a man with dyspnoea and cough. His chest radiogram showed hydrothorax on the left side. Neither the examinations of the pleural liquid, nor the CT-guided fine needle biopsy established the diagnosis. CT showed features suggestive of pleural mesothelioma. The diagnosis was confirmed by thoracoscopy. Although no neoplastic cells were found in the thoracoscopic specimen from the supradiaphragmatic tumor, we assumed that to be a case of a diffuse, primarily local form of mesothelioma. Diagnostics of pleural mesothelioma is very difficult. CT and thoracoscopy seem to be very valuable diagnostic methods. It is worth remembering that pleural mesothelioma can have a local form which may transform into a diffuse one.

  13. Rare Case of Intratracheal Metastasis Detected on 68Ga-Prostate-Specific Membrane Antigen PET/CT Scan in a Case of Thyroglobulin Elevated Negative Iodine Scan Syndrome.

    PubMed

    Sasikumar, Arun; Joy, Ajith; Pillai, M R A; Oommen, Karuna Elza; Jayakumar, R

    2018-04-01

    A 64-year-old woman underwent completion thyroidectomy with upper tracheal ring resection and right-sided neck dissection for papillary carcinoma of the thyroid infiltrating the trachea and was given I radioiodine treatment. Three years later, she presented with hemoptysis. On evaluation, she had increased serum thyroglobulin and negative iodine scan (TENIS). F-FDG PET/CT scan did not identify any site of disease. One year later, Ga-PSMA scan done revealed a moderate focal tracer-avid intratracheal soft tissue; biopsy revealed it to be metastatic papillary carcinoma of the thyroid. This case kindles the possibility of using Ga-PSMA PET/CT to reveal occult disease in cases of TENIS.

  14. Management of apraxic gait in a stroke patient.

    PubMed

    Jantra, P; Monga, T N; Press, J M; Gervais, B J

    1992-01-01

    There is little information available regarding management of apraxic gait. We present a 61-year-old man with a five-year history of right-sided cerebrovascular accident, apraxic gait, difficulty in walking, and frequent falls. A CT head scan revealed moderate cerebral atrophy, a small lacunar infarction. The patient was unable to initiate walking, was bed ridden and housebound. Traditional gait training and balance exercises failed to improve his gait. Two straight canes were modified by fixing florescent horizontal projections approximately two inches up from the tip of the cane. The patient was instructed to step over the horizontal projected portion, making use of visual cues from the florescent painted projections. The patient became independent with safe ambulation after practicing for approximately three weeks and was discharged home.

  15. [The cross-sectional area of the median nerve by sonography in the diagnosis of carpal tunnel syndrome].

    PubMed

    Sabag-Ruiz, Enrique; Higuera-Lugo, Cirilo Omar; Ornelas-Aguirre, José Manuel; Gómez-Alcalá, Alejandro V

    2009-01-01

    To measure the median nerve cross-sectional area (MNCSA) at the carpal tunnel (CT) level by sonography (S) in a Mexican population. A comparative cross-sectional design study with a nonprobabilistic sampling with 50 women and 50 men in good health were submitted for measuring MNCSA at the level of the CT. Other variables like sex; side and degree of daily hand activity were also studied. The analysis was made by descriptive statistics, and Mann-Whitney U or Kruskal-Wallis tests. The mean MNCSA was 0.063 +/- 0.015 cm(2), in women; in men it was 0.072 +/- 0.018 cm(2); the difference was significant (p < 0.004). The median MNCSA among women was 0.062 cm(2) in the right side and 0.060 cm(2) in the left (90th percentile for both hands of 0.084 cm(2)); in men, it was of 0.070 cm(2) in the right hand and of 0.069 cm(2) in the left (90th percentile for both hands of 0.097 cm(2)). The difference between women and men was significant in each side, but not between right and left hands (p = 0.21). There was no correlation between age and MNCSA on either side, or with hand activity. A MNCSA value of 0.1 cm(2) for men and 0.09 cm(2) for women is proposed as a standard parameter for the Mexican population.

  16. 30. Valves under central corridor of filtration bed building. Main ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. Valves under central corridor of filtration bed building. Main flood valves is at left and crossover valve is a right. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  17. 37. INTERIOR VIEW OF TANK FROM THE TOP, SHOWING LADDERS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. INTERIOR VIEW OF TANK FROM THE TOP, SHOWING LADDERS ON SIDES AND THE WATERTIGHT DOOR OF THE 18-FOOT LOCK No date - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  18. Experience in the application of Java Technologies in telemedicine

    PubMed Central

    Fedyukin, IV; Reviakin, YG; Orlov, OI; Doarn, CR; Harnett, BM; Merrell, RC

    2002-01-01

    Java language has been demonstrated to be an effective tool in supporting medical image viewing in Russia. This evaluation was completed by obtaining a maximum of 20 images, depending on the client's computer workstation from one patient using a commercially available computer tomography (CT) scanner. The images were compared against standard CT images that were viewed at the site of capture. There was no appreciable difference. The client side is a lightweight component that provides an intuitive interface for end users. Each image is loaded in its own thread and the user can begin work after the first image has been loaded. This feature is especially useful on slow connection speed, 9.6 Kbps for example. The server side, which is implemented by the Java Servlet Engine works more effective than common gateway interface (CGI) programs do. Advantages of the Java Technology place this program on the next level of application development. This paper presents a unique application of Java in telemedicine. PMID:12459045

  19. The effect of images of Michelle Obama's face on trick-or-treaters' dietary choices: A randomized control trial.

    PubMed

    Aronow, Peter M; Karlan, Dean; Pinson, Lauren E

    2018-01-01

    To evaluate the microfoundations of a personality-inspired public health campaign's influence on minors. Multi-year randomized control trial. Economics professor's front porch in New Haven, CT. 1223 trick-or-treaters in New Haven over three years; on average, 8.5 years old and 53% male (among children whose gender was identifiable). Trick-or-treaters over the age of three that approached the house. Random assignment to the Michelle Obama side of the porch or the Comparison side of the porch. Selection of fruit over candy. Difference-in-means estimates. We estimate that viewing a photograph of Michelle Obama's face relative to control conditions caused children to be 19% more likely to choose fruit over candy. Michelle Obama's initiative to reduce childhood obesity has influenced children's dietary preferences. Whether this influence extends beyond Halloween trick-or-treating in New Haven, CT on the porch of an economics professor requires further research.

  20. "Unusual brain stone": heavily calcified primary neoplasm with some features suggestive of angiocentric glioma.

    PubMed

    Sajjad, Jahangir; Kaliaperumal, Chandrasekaran; Bermingham, Niamh; Marks, Charles; Keohane, Catherine

    2015-11-01

    This 40-year-old man presented with a 5-month history of progressive right-sided headache associated with visual blurring. He also had a history of epilepsy but had been seizure free with medication for the past 10 years. An initial CT scan of his brain performed 16 years previously had revealed a small area of calcification in the right parietal region. In the current presentation, he had a left-sided homonymous hemianopia but no other neurological deficits. A CT scan of his brain showed a much larger calcified, partly cystic lesion in the right parietal region. Because he was symptomatic, the lesion was excised and the cyst was drained. Histological examination of the excised tissue showed an unusual primary tumor that was difficult to classify but had some features of angiocentric glioma. The heavy calcification, mixed-density cell population, and regions with features of angiocentric glioma were most unusual. The patient remained asymptomatic 5 years after surgery, and follow-up scans did not show recurrence.

  1. Experience in the application of Java Technologies in telemedicine.

    PubMed

    Fedyukin, IV; Reviakin, YG; Orlov, OI; Doarn, CR; Harnett, BM; Merrell, RC

    2002-09-17

    Java language has been demonstrated to be an effective tool in supporting medical image viewing in Russia. This evaluation was completed by obtaining a maximum of 20 images, depending on the client's computer workstation from one patient using a commercially available computer tomography (CT) scanner. The images were compared against standard CT images that were viewed at the site of capture. There was no appreciable difference. The client side is a lightweight component that provides an intuitive interface for end users. Each image is loaded in its own thread and the user can begin work after the first image has been loaded. This feature is especially useful on slow connection speed, 9.6 Kbps for example. The server side, which is implemented by the Java Servlet Engine works more effective than common gateway interface (CGI) programs do. Advantages of the Java Technology place this program on the next level of application development. This paper presents a unique application of Java in telemedicine.

  2. Do Open Reduction and Internal Fixation With Articular Disc Anatomical Reduction and Rigid Anchorage Manifest a Promising Prospect in the Treatment of Intracapsular Fractures?

    PubMed

    Cai, Bo-Lei; Ren, Rong; Yu, Hong-Bo; Liu, Peng-Chao; Shen, Steve G F; Shi, Jun

    2018-05-01

    In response to the increased attention to soft tissue reduction in the treatment of intracapsular condylar fractures (ICFs), a modified open reduction technique is proposed and its functional and radiographic outcomes were evaluated in this study. This is a retrospective case series study of patients with all ICF types that were treated with open reduction and internal fixation (ORIF) with articular disc anatomic reduction and rigid anchorage. Inclusion and exclusion criteria were strictly applied. Preoperative and postoperative clinical examinations of malocclusion, maximum incisor opening (MIO), laterotrusion, and temporomandibular disorder symptoms were recorded and analyzed. Computed tomography (CT) and magnetic resonance imaging (MRI) were used to assess articular position and condylar morphology and position. Thirty-four patients with ICFs (47 sides) were treated with the modified ORIF technique. At 6 months of follow-up, no malocclusion was found and the MIO considerably expanded to 3.56 ± 0.13 cm. Only 4 patients (12%) had temporomandibular joint discomfort with mouth opening. Interestingly, for unilateral type B ICFs, the laterotrusion distance to the ORIF sides was notably longer than to the non-ORIF sides. Postoperative CT and MRI showed that all fragments were properly reduced and the condyles were in the normal position. Postoperative anterior disc displacement occurred in 4 sides and condylar morphologic abnormalities (slight surface roughening and articular cartilage absorption) occurred in 3 sides (6.4%). This modified ORIF technique, which achieved good outcomes after treatment of all ICF types, shows promise for the treatment of ICFs. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Automated labeling of log features in CT imagery of multiple hardwood species

    Treesearch

    Daniel L. Schmoldt; Jing He; A. Lynn Abbott

    2000-01-01

    Before noninvasive scanning, e.g., computed tomography (CT), becomes feasible in industrial saw-mill operations, we need a procedure that can automatically interpret scan information in order to provide the saw operator with information necessary to make proper sawing decisions. To this end, we have worked to develop an approach for automatic analysis of CT images of...

  4. Brain Positron Emission Tomography-Computed Tomography Gender Differences in Tinnitus Patients.

    PubMed

    Shlamkovich, Nathan; Gavriel, Haim; Eviatar, Ephraim; Lorberboym, Mordechay; Aviram, Eliad

    2016-10-01

    Increased metabolism in the left auditory cortex has been reported in tinnitus patients. However, gender difference has not been addressed. To assess the differences in Positron emission tomography-computed tomography (PET-CT) results between the genders in tinnitus patients. Retrospective cohort. Included were patients referred to our clinic between January 2011 and August 2013 who complained of tinnitus and underwent fluorodeoxyglucose (FDG)-PET to assess brain metabolism. Univariate and multivariate nominal logistic regressions were used to evaluate the association between upper temporal gyrus (UTG; right and left) and gender. Included were 140 patients (87 males) with an average age of 52.5 yr (median = 53.1). Bilateral tinnitus was found in 85 patients (60.7%), left sided in 30 (21.4%), and right sided in 21(15%). Increased uptake in the UTG was found in 60% of the patients on either side. Males had a statistically significant increased uptake in the UTG in those with unilateral tinnitus and in the entire population. We present the largest study reported so far on tinnitus patients who have undergone FDG-PET-CT. We found a statistically significant difference between the genders in FDG uptake by the UTG. Further investigations should be undertaken to reveal the etiologies for these differences and to assess different therapeutic protocols according to gender. American Academy of Audiology

  5. 18F-FDG PET/CT imaging of atypical subacute thyroiditis in thyrotoxicosis: A case report.

    PubMed

    Yoshida, Katsuya; Yokoh, Hidetaka; Toriihara, Akira; Fujii, Hayahiko; Harata, Naoki; Isogai, Jun; Tateishi, Ukihide

    2017-07-01

    In addition to its established role in oncologic imaging, F-fluorodeoxyglucose positron emission tomography/computed tomography (F-FDG PET/CT) is useful for the assessment of inflammatory activity. However, subacute thyroiditis (SAT) in thyrotoxicosis is rarely detected during these scans. A 66-year-old man with SAT in thyrotoxicosis demonstrated symptoms of transient fatigue, headache, and fever, without typical neck pain. Using F-FDG PET/CT, we found increased F-FDG uptake in the thyroid gland, predominantly in the right side due to SAT. We also observed a coexisting decrease in F-FDG uptake in the liver and increased F-FDG uptake in skeletal muscle due to thyrotoxicosis. Using F-FDG PET/CT, the combined observations of increased F-FDG uptake in the thyroid and skeletal muscle, and decreased F-FDG uptake in the liver, even when the typical symptom of neck pain is subtle or absent, may be helpful for the differential diagnosis of SAT in thyrotoxicosis.

  6. A new timing detector for the CT-PPS project

    NASA Astrophysics Data System (ADS)

    Arcidiacono, R.; Cms; TOTEM Collaborations

    2017-02-01

    The CT-PPS detector will be installed close to the beam line on both sides of CMS, 200 m downstream the interaction point. This detector will measure forward scattered protons, allowing detailed studies of diffractive hadron physics and Central Exclusive Production. The main components of the CT-PPS detector are a silicon tracking system and a timing system. In this contribution we present the proposal of an innovative solution for the timing system, based on Ultra-Fast Silicon Detectors (UFSD). UFSD are a novel concept of silicon detectors potentially able to obtain the necessary time resolution (∼20 ps on the proton arrival time). The use of UFSD has also other attractive features as its material budget is small and the pixel geometries can be tailored to the precise physics distribution of protons. UFSD prototypes for CT-PPS have been designed by CNM (Barcelona) and FBK (Trento): we will present the status of the sensor productions and of the low-noise front-end electronics currently under development and test.

  7. Choroidal thickness alterations in diabetic nephropathy patients with early or no diabetic retinopathy.

    PubMed

    Kocasarac, Can; Yigit, Yavuz; Sengul, Erkan; Sakalar, Yildirim Beyazit

    2018-04-01

    To assess changes in choroidal thickness (CT) in diabetes patients with and without diabetic nephropathy using enhanced depth imaging spectral domain optical coherence tomography (EDI-OCT). Thirty-five type 2 diabetes patients with a diagnosis of diabetic nephropathy (DNP) in nephrology department and 35 type 2 diabetes patients without nephropathy (non-DNP) were included in our prospective study consecutively. The control group comprised 34 healthy individuals. CT measurements were recorded under the fovea and at 1500 µm from the foveal center in the nasal and temporal sides. The study parameters also included age, refractive error, axial length, intraocular pressure, HbA1c, glomerular filtration rate and proteinuria amount. The subfoveal, temporal and nasal choroidal thickness was noted to be thinner in patients with DNP compared with non-DNP and normal subjects (p < 0.05). However, CT measurements did not show any difference between the healthy and non-DNP group. CT decreases significantly in diabetic patients when diabetic nephropathy accompanies diabetes mellitus.

  8. Abdominal and Pelvic CT

    MedlinePlus Videos and Cool Tools

    ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  9. NETL CT Imaging Facility

    ScienceCinema

    None

    2018-02-13

    NETL's CT Scanner laboratory is equipped with three CT scanners and a mobile core logging unit that work together to provide characteristic geologic and geophysical information at different scales, non-destructively.

  10. 22. Float located adjacent to entry stair in filtration bed. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. Float located adjacent to entry stair in filtration bed. The float actuates a valve that maintains water level over the bed. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  11. 2. View east of filtration bed building. Access bridge to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. View east of filtration bed building. Access bridge to earth covering over reinforced concrete roof is at center right of photograph. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  12. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    PubMed

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  13. Superficial subarachnoid cerebrospinal fluid space expansion after surgical drainage of chronic subdural hematoma.

    PubMed

    Tosaka, Masahiko; Tsushima, Yoshito; Watanabe, Saiko; Sakamoto, Kazuya; Yodonawa, Masahiko; Kunimine, Hideo; Fujita, Haruyasu; Fujii, Takashi

    2015-07-01

    The present study examined the computed tomography (CT) findings after surgery and overnight drainage for chronic subdural hematoma (CSDH) to clear the significance of inner superficial subarachnoid CSF space and outer subdural hematoma cavity between the brain surface and the inner skull. A total of 73 sides in 60 patients were evaluated. Head CT was performed on the day after surgery and overnight drainage (1st CT), within 3 weeks of surgery (2nd CT), and more than 3 weeks after surgery (3rd CT). Subdural and subarachnoid spaces were identified to focus on density of fluid, shape of air collection, and location of silicone drainage tube, etc. Cases with subdural space larger than the subarachnoid CSF space were classified as Group SD between the brain and the skull. Cases with subarachnoid CSF space larger than the subdural space were classified as Group SA. Cases with extremely thin (<3 mm) spaces between the brain and the skull were classified as Group NS. Group SA, SD, and NS accounted for 31.9, 55.6 and 12.5% of cases on the 1st CT. No statistical differences were found between Groups SA, SD, and NS in any clinical factors, including recurrence. Group SA were found significantly more on 1st CT than on 2nd and 3rd CT. Subarachnoid CSF space sometimes expands between the brain and skull on CT after surgical overnight drainage. Expansion of the arachnoid space may be a passive phenomenon induced by overnight drainage and delayed re-expansion of the brain parenchyma.

  14. CT scan (image)

    MedlinePlus

    CT stands for computerized tomography. In this procedure, a thin X-ray beam is rotated around the ... D image of a section through the body. CT scans are very detailed and provide excellent information ...

  15. Head CT (image)

    MedlinePlus

    CT stands for computerized tomography. In this procedure, a thin X-ray beam is rotated around the ... D image of a section through the body. CT scans are very detailed and provide excellent information ...

  16. A standardized technique of systematic mediastinal lymph node dissection by video-assisted thoracoscopic surgery (VATS) leads to a high rate of nodal upstaging in early-stage non-small cell lung cancer.

    PubMed

    Reichert, Martin; Steiner, Dagmar; Kerber, Stefanie; Bender, Julia; Pösentrup, Bernd; Hecker, Andreas; Bodner, Johannes

    2016-03-01

    A substantial part of the oncologic surgical procedure in non-small cell lung cancer (NSCLC) is systematic lymph node dissection (sLND). However, controversies still exist regarding the quality of minimally invasive (video-assisted thoracoscopic surgery, VATS) sLND in oncologic resections. The rate of stage migration from clinical to pathological N-status has been discussed as one parameter for the quality of sLND. Between March 2011 and May 2014, seventy-seven patients (62 male, 15 female) were scheduled for anatomical lung resection and sLND by VATS for clinical stage I (UICC 7th edition) NSCLC. Preoperative staging was performed by [18F]-fluorodesoxyglucose positron emission tomography with computed tomography (FDG-PET/CT). Patient data were retrospectively analyzed with regard to divergence in clinical and pathological N-factor. FDG-PET/CTs of patients with lymph node (LN) upstaging after VATS resections were blindly re-evaluated by an experienced radiologist. In FDG-PET/CT, preoperative tumor stage was cT1N0M0 in 41 (53.2%) and cT2aN0M0 in 28 (36.4%) patients. In six (7.8%) patients the primary tumor was not suspicious for malignancy, and in two (2.6%) patients the tumor was not evaluable due to prior wedge resection before FDG-PET/CT. Thirty-one (40.3%) left-sided and 46 (59.7%) right-sided pulmonary resections with sLND were performed; 19.57 ± 0.99 LNs were dissected. In 13 (16.9%) patients a nodal stage migration from preoperative clinical to postoperative pathological N-stage was observed [cN0 to pN1 in 9 (11.7%) and cN0 to pN2 in 4 (5.2%) cases]. In correlation to the clinical T-factor, the rate of N-factor upstaging for cT1 was 12.2% and for cT2a was 28.6%, respectively. In 50% of the patients with postoperative nodal staging shift, no changes were observed on re-evaluation of the preoperative FDG-PET/CT. In this series of clinical stage I NSCLC patients, the rate of nodal stage migration after sLND by VATS is higher than previously reported. Prospective randomized controlled trials are needed to prove the oncologic quality of a sLND by VATS versus standard open approach.

  17. Iterative CT shading correction with no prior information

    NASA Astrophysics Data System (ADS)

    Wu, Pengwei; Sun, Xiaonan; Hu, Hongjie; Mao, Tingyu; Zhao, Wei; Sheng, Ke; Cheung, Alice A.; Niu, Tianye

    2015-11-01

    Shading artifacts in CT images are caused by scatter contamination, beam-hardening effect and other non-ideal imaging conditions. The purpose of this study is to propose a novel and general correction framework to eliminate low-frequency shading artifacts in CT images (e.g. cone-beam CT, low-kVp CT) without relying on prior information. The method is based on the general knowledge of the relatively uniform CT number distribution in one tissue component. The CT image is first segmented to construct a template image where each structure is filled with the same CT number of a specific tissue type. Then, by subtracting the ideal template from the CT image, the residual image from various error sources are generated. Since forward projection is an integration process, non-continuous shading artifacts in the image become continuous signals in a line integral. Thus, the residual image is forward projected and its line integral is low-pass filtered in order to estimate the error that causes shading artifacts. A compensation map is reconstructed from the filtered line integral error using a standard FDK algorithm and added back to the original image for shading correction. As the segmented image does not accurately depict a shaded CT image, the proposed scheme is iterated until the variation of the residual image is minimized. The proposed method is evaluated using cone-beam CT images of a Catphan©600 phantom and a pelvis patient, and low-kVp CT angiography images for carotid artery assessment. Compared with the CT image without correction, the proposed method reduces the overall CT number error from over 200 HU to be less than 30 HU and increases the spatial uniformity by a factor of 1.5. Low-contrast object is faithfully retained after the proposed correction. An effective iterative algorithm for shading correction in CT imaging is proposed that is only assisted by general anatomical information without relying on prior knowledge. The proposed method is thus practical and attractive as a general solution to CT shading correction.

  18. CFD simulation of hemodynamics in sequential and individual coronary bypass grafts based on multislice CT scan datasets.

    PubMed

    Hajati, Omid; Zarrabi, Khalil; Karimi, Reza; Hajati, Azadeh

    2012-01-01

    There is still controversy over the differences in the patency rates of the sequential and individual coronary artery bypass grafting (CABG) techniques. The purpose of this paper was to non-invasively evaluate hemodynamic parameters using complete 3D computational fluid dynamics (CFD) simulations of the sequential and the individual methods based on the patient-specific data extracted from computed tomography (CT) angiography. For CFD analysis, the geometric model of coronary arteries was reconstructed using an ECG-gated 64-detector row CT. Modeling the sequential and individual bypass grafting, this study simulates the flow from the aorta to the occluded posterior descending artery (PDA) and the posterior left ventricle (PLV) vessel with six coronary branches based on the physiologically measured inlet flow as the boundary condition. The maximum calculated wall shear stress (WSS) in the sequential and the individual models were estimated to be 35.1 N/m(2) and 36.5 N/m(2), respectively. Compared to the individual bypass method, the sequential graft has shown a higher velocity at the proximal segment and lower spatial wall shear stress gradient (SWSSG) due to the flow splitting caused by the side-to-side anastomosis. Simulated results combined with its surgical benefits including the requirement of shorter vein length and fewer anastomoses advocate the sequential method as a more favorable CABG method.

  19. Pleural mesothelioma – case report

    PubMed Central

    Klawiter, Anna; Damaszke, Tomasz

    2010-01-01

    Summary Background: Pleural mesothelioma is a very rare neoplasm; especially the local form. The diagnostics is difficult and the prognosis unfavourable. Case Report: We presented a case of a man with dyspnoea and cough. His chest radiogram showed hydrothorax on the left side. Neither the examinations of the pleural liquid, nor the CT-guided fine needle biopsy established the diagnosis. CT showed features suggestive of pleural mesothelioma. The diagnosis was confirmed by thoracoscopy. Although no neoplastic cells were found in the thoracoscopic specimen from the supradiaphragmatic tumor, we assumed that to be a case of a diffuse, primarily local form of mesothelioma. Conclusions: Diagnostics of pleural mesothelioma is very difficult. CT and thoracoscopy seem to be very valuable diagnostic methods. It is worth remembering that pleural mesothelioma can have a local form which may transform into a diffuse one. PMID:22802809

  20. Control of interfacial charge-transfer interaction of dye and p-CuI in solid-state dye-sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Moribe, Shinya; Kato, Naohiko; Higuchi, Kazuo; Mizumoto, Katsuyoshi; Toyoda, Tatsuo

    2017-04-01

    We systematically investigated the photovoltaic and absorption characteristics of solid-state dye-sensitized solar cells with CuI to elucidate the impact of the interaction between the dye and CuI. For the ruthenium complex N719, the incident photon-to-current conversion efficiency (IPCE) on the longer-wavelength side decreased owing to the change of the metal-to-ligand charge transfer (CT) of N719 due to the interaction between the thiocyanate groups of N719 and CuI. In contrast, when D149 — which included rhodanine groups — was used, the interaction with CuI and the resultant CT increased the IPCE. The results provide a new strategy for improving the photovoltaic performance by controlling the interfacial CT between the dye and CuI.

  1. WE-E-18C-01: Multi-Energy CT: Current Status and Recent Innovations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pelc, N; McCollough, C; Yu, L

    2014-06-15

    Conventional computed tomography (CT) uses a single polychromatic x-ray spectrum and energy integrating detectors, and produces images whose contrast depends on the effective attenuation coefficient of the broad spectrum beam. This can introduce errors from beam hardening and does not produce the optimal contrast-to-noise ratio. In addition, multiple materials can have the same effective attenuation coefficient, causing different materials to be indistinguishable in conventional CT images. If transmission measurements at two or more energies are obtained, even with polychromatic beams, more specific information about the object can be obtained. If the object does not contain materials with k-edges in themore » spectrum, the x-ray attenuation can be well-approximated by a linear combination of two processes (photoelectric absorption and Compton scattering) or, equivalently, two basis materials. For such cases, two spectral measurements suffice, although additional measurements can provide higher precision. If K-edge materials are present, additional spectral measurements can allow these materials to be isolated. Current commercial implementations use varied approaches, including two sources operating a different kVp, one source whose kVp is rapidly switched in a single scan, and a dual layer detector that can provide spectral information in every reading. Processing of the spectral information can be performed in the raw data domain or in the image domain. The process of calculating the amount of the two basis functions implicitly corrects for beam hardening and therefore can lead to improvements in quantitative accuracy. Information can be extracted to provide material specific information beyond that of conventional CT. This additional information has been shown to be important in several clinical applications, and can also lead to more efficient clinical protocols. Recent innovations in x-ray sources, detectors, and systems have made multi-energy CT much more practical and improved its performance. In addition, this is a very active area of research and further improvements are expected through further technological improvements. Learning Objectives: Basic principles of multi-energy CT Current implementations of mutli-energy CT Data and image analysis methods in multi-energy CT Current clinical applications of dual energy CT5. recent innovations and anticipated advances in multi-energy CT.« less

  2. 29. Basement under central corridor. Shaft on right actuates cross ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. Basement under central corridor. Shaft on right actuates cross over valve. Shaft at left operates main flood valve to admit water into the bed. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  3. 8. POWERHOUSE, LOWER LEVEL, LEFT, GOVERNOR DRIVE MOTOR WITH BELT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. POWERHOUSE, LOWER LEVEL, LEFT, GOVERNOR DRIVE MOTOR WITH BELT ON RIGHT, HYDRAULIC PUMP WITH RESERVOIR TANK, STEAM HEAT PIPES ON BACK WALL LOOKING NORTHEAST - Dayville Mills Hydroelectric Facility, Powerhouse, North side of Route 101, .5 mile west of Route 395, Killingly Center, Windham County, CT

  4. 21. Overflow pipe in filtration bed. Located at each corner ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Overflow pipe in filtration bed. Located at each corner of the bed, the pipes drain off any excess water and maintain a limit on water depth. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  5. 49. VIEW LOOKING NORTHEAST AT EXCITER GENERATOR "c" LOCATED UNDER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    49. VIEW LOOKING NORTHEAST AT EXCITER GENERATOR "c" LOCATED UNDER CONTROL ROOM ON SOUTH SIDE OF TURBINE HALL. THE EXCITER GENERATORS PROVIDED DIRECT CURRENT TO THE FIELD COILS OF THE MAIN GENERATORS. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  6. 11. Historic American Buildings Survey Photocopy PRINCIPAL FLOOR PLAN, SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Historic American Buildings Survey Photocopy PRINCIPAL FLOOR PLAN, SOUTH SIDE ELEVATION ARCHITECT'S ORIGINAL PLAN Restricted: Not to be reproduced without written permission from Beinecke Rare Books Library, Yale University, New Haven, Connecticut - John Pitkin Norton House, 52 Hillhouse Avenue, New Haven, New Haven County, CT

  7. Critical Thinking Measurement in ICT

    ERIC Educational Resources Information Center

    Shannon, Li-Jen; Schneider, Solomon; Bennett, Judith F.

    2010-01-01

    This study examined the status of critical thinking (CT) and reasoning skills in information communication and technology (ICT) for 190 college students in a higher education system. It analyzed how the students performed in CT, reasoning, and internet copyright and ethical issues. A CT assessment was designed to analyze the CT and reasoning…

  8. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems

    NASA Astrophysics Data System (ADS)

    Du, Louise Y.; Umoh, Joseph; Nikolov, Hristo N.; Pollmann, Steven I.; Lee, Ting-Yim; Holdsworth, David W.

    2007-12-01

    Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 µm, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm-1 and noise of ±35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy.

  9. SU-E-J-32: Calypso(R) and Laser-Based Localization Systems Comparison for Left-Sided Breast Cancer Patients Using Deep Inspiration Breath Hold

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, S; Kaurin, D; Sweeney, L

    2014-06-01

    Purpose: Our institution uses a manual laser-based system for primary localization and verification during radiation treatment of left-sided breast cancer patients using deep inspiration breath hold (DIBH). This primary system was compared with sternum-placed Calypso(R) beacons (Varian Medical Systems, CA). Only intact breast patients are considered for this analysis. Methods: During computed tomography (CT) simulation, patients have BB and Calypso(R) surface beacons positioned sternally and marked for free-breathing and DIBH CTs. During dosimetry planning, BB longitudinal displacement between free breathing and DIBH CT determines laser mark (BH mark) location. Calypso(R) beacon locations from the DIBH CT are entered at themore » Tracking Station. During Linac simulation and treatment, patients inhale until the cross-hair and/or lasers coincide with the BH Mark, which can be seen using our high quality cameras (Pelco, CA). Daily Calypso(R) displacement values (difference from the DIBH-CT-based plan) are recorded.The displacement mean and standard deviation was calculated for each patient (77 patients, 1845 sessions). An aggregate mean and standard deviation was calculated weighted by the number of patient fractions.Some patients were shifted based on MV ports. A second data set was calculated with Calypso(R) values corrected by these shifts. Results: Mean displacement values indicate agreement within 1±3mm, with improvement for shifted data (Table). Conclusion: Both unshifted and shifted data sets show the Calypso(R) system coincides with the laser system within 1±3mm, demonstrating either localization/verification system will Resultin similar clinical outcomes. Displacement value uncertainty unilaterally reduces when shifts are taken into account.« less

  10. Long-term absorption of beta-tricalcium phosphate poly-L-lactic acid interference screws.

    PubMed

    Barber, F Alan; Dockery, William D

    2008-04-01

    The purpose of this study was to evaluate the long-term in vivo degradation of biodegradable interference screws made of poly-L-lactic acid (PLLA) and beta-tricalcium phosphate (beta-TCP). Twenty patients undergoing patellar tendon autograft anterior cruciate ligament reconstruction fixed at both the femur and tibia with beta-TCP-PLLA screws at least 44 months earlier were evaluated by physical, radiographic, and computed tomography (CT) evaluations. This study was approved by the institutional review board. Lysholm, Tegner, Cincinnati, and International Knee Documentation Committee scores were also obtained. CT data were measured in Hounsfield units. We evaluated 13 male and 7 female patients at a mean of 50 months after surgery (range, 44 to 56 months). CT scans and radiographs showed the bone plug fused to the tunnel wall with no beta-TCP-PLLA screw remaining. The screws were replaced with clearly calcified non-trabecular material, denser than soft tissue. Osteoconductivity was present in 75% of the tunnels and complete in 10%. No positive pivot-shift tests were found. Lysholm, Tegner, and Cincinnati scores improved from 60.4, 3.7, and 53.3, respectively, preoperatively to 90.8, 5.8, and 86.4, respectively, at follow-up. The mean side-to-side difference determined by use of the KT arthrometer (MEDmetric, San Diego, CA) was 0.4 mm. The beta-TCP-PLLA interference screw (Bilok; ArthroCare, Sunnyvale, CA) completely degraded, and no remnant was present 4 years after insertion. Osteoconductivity was confirmed by CT scans at 75% of the screw sites and completely filled the site in 10%. The addition of beta-TCP to PLLA results in a biocomposite interference screw that is osteoconductive. Level IV, therapeutic case series.

  11. Super resolution reconstruction of μ-CT image of rock sample using neighbour embedding algorithm

    NASA Astrophysics Data System (ADS)

    Wang, Yuzhu; Rahman, Sheik S.; Arns, Christoph H.

    2018-03-01

    X-ray computed tomography (μ-CT) is considered to be the most effective way to obtain the inner structure of rock sample without destructions. However, its limited resolution hampers its ability to probe sub-micro structures which is critical for flow transportation of rock sample. In this study, we propose an innovative methodology to improve the resolution of μ-CT image using neighbour embedding algorithm where low frequency information is provided by μ-CT image itself while high frequency information is supplemented by high resolution scanning electron microscopy (SEM) image. In order to obtain prior for reconstruction, a large number of image patch pairs contain high- and low- image patches are extracted from the Gaussian image pyramid generated by SEM image. These image patch pairs contain abundant information about tomographic evolution of local porous structures under different resolution spaces. Relying on the assumption of self-similarity of porous structure, this prior information can be used to supervise the reconstruction of high resolution μ-CT image effectively. The experimental results show that the proposed method is able to achieve the state-of-the-art performance.

  12. Symptoms Experienced and Information Needs of Women Receiving Chemotherapy.

    PubMed

    Uysal, Neşe; Toprak, Filiz Ünal; Kutlutsürkan, Sevinç; Erenel, Ayten Şentürk

    2018-01-01

    This study is carried out to determine the symptoms and information necessity on chemotherapy (CT) treatment of the women with breast cancer. A total of 170 women older than 18 years old, who receive CT with breast cancer diagnosis, are volunteered to participate in the study. Mixed method was used in the study. Data are collected using Descriptive Data Form, Interview Form and Memorial Symptom Assessment Scale. As a result of the cluster analysis, four clusters and the symptoms within have been obtained. These are: pain, lack of energy, feeling drowsy, sweat, swelling of hands, and feet in the first cluster; feeling nervous, difficulty sleeping, feeling sad, worrying in the second cluster; nausea, feeling bloating, change in the way food tastes, hair loss, constipation in the third cluster; vomiting, diarrhea, problems with sexual interest, lack of appetite, dizziness, and weight loss in the forth cluster. Women's information necessity related to the CT are follows: the effects of CT, other treatment options beyond CT, complementary methods, the effect of the CT treatment on reproductive health and sexuality, nutrition, and symptom control. The results of this study will enable determination of symptom clusters, which health professionals are easier to focus on these symptoms. An understanding information need of patients can help to ensure that individual's coping strategies and self-management.

  13. Raymark Public Open House and General Information Session

    EPA Pesticide Factsheets

    The USEPA, CTDEEP, CT DPH, & the Stratford Health Department will host an Open House & General Information Session for Stratford, CT residents to learn more about the Raymark Industries, Inc. Superfund Site, on Tuesday, May 23, 2017...

  14. 76 FR 61559 - Airworthiness Directives; General Electric Company (GE) CT7-8, CT7-8A, CT7-8A1, CT7-8E, and CT7...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-05

    ... new airworthiness directive (AD) for the products listed above. This AD was prompted by four reports of unrecoverable engine stalls, during hover in a left-roll attitude. This AD requires the... service information at the FAA, Engine & Propeller Directorate, 12 New England Executive Park, Burlington...

  15. Early sepsis, obstructive jaundice and right-sided diaphragmatic hernia in the newborn.

    PubMed

    García-Muñoz, F; Santana, C; Reyes, D; Wiehoff, A; López-Pinto, J M; García-Alix, A

    2001-01-01

    A male newborn was admitted to our Unit because of early sepsis and shock. He required antimicrobial therapy and mechanical ventilation and initially did well, although he exhibited jaundice and cholestasis. During the second week he deteriorated, with radiological opacification of the right hemithorax and pleural effusion, and did poorly in spite of antibiotical therapy and drainage of the effusion. In the third week, the X-ray suggested some bowel loops in the right hemithorax. A right-sided diaphragmatic hernia was confirmed by a CT-scan, and surgery was performed with good outcome. The association of delayed-onset right-sided CDH following early sepsis and obstructive jaundice has not been published before, and illustrates a scarcely known form of presentation of this condition.

  16. Inter-observer variability in diagnosing radiological features of aneurysmal subarachnoid hemorrhage; a preliminary single centre study comparing observers from different specialties and levels of training.

    PubMed

    Siddiqui, Usman T; Khan, Anjum F; Shamim, Muhammad Shahzad; Hamid, Rana Shoaib; Alam, Muhammad Mehboob; Emaduddin, Muhammad

    2014-01-01

    A noncontrast computed tomography (CT) scan remains the initial radiological investigation of choice for a patient with suspected aneurysmal subarachnoid hemorrhage (aSAH). This initial scan may be used to derive key information about the underlying aneurysm which may aid in further management. The interpretation, however, is subject to the skill and experience of the interpreting individual. The authors here evaluate the interpretation of such CT scans by different individuals at different levels of training, and in two different specialties (Radiology and Neurosurgery). Initial nonontrast CT scan of 35 patients with aSAH was evaluated independently by four different observers. The observers selected for the study included two from Radiology and two from Neurosurgery at different levels of training; a resident currently in mid training and a resident who had recently graduated from training of each specialty. Measured variables included interpreter's suspicion of presence of subarachnoid blood, side of the subarachnoid hemorrhage, location of the aneurysm, the aneurysm's proximity to vessel bifurcation, number of aneurysm(s), contour of aneurysm(s), presence of intraventricular hemorrhage (IVH), intracerebral hemorrhage (ICH), infarction, hydrocephalus and midline shift. To determine the inter-observer variability (IOV), weighted kappa values were calculated. There was moderate agreement on most of the CT scan findings among all observers. Substantial agreement was found amongst all observers for hydrocephalus, IVH, and ICH. Lowest agreement rates were seen in the location of aneurysm being supra or infra tentorial. There were, however, some noteworthy exceptions. There was substantial to almost perfect agreement between the radiology graduate and radiology resident on most CT findings. The lowest agreement was found between the neurosurgery graduate and the radiology graduate. Our study suggests that although agreements were seen in the interpretation of some of the radiological features of aSAH, there is still considerable IOV in the interpretation of most features among physicians belonging to different levels of training and different specialties. Whether these might affect management or outcome is unclear.

  17. Does overgrowth of costal cartilage cause pectus carinatum? A three-dimensional computed tomography evaluation of rib length and costal cartilage length in patients with asymmetric pectus carinatum

    PubMed Central

    Park, Chul Hwan; Kim, Tae Hoon; Haam, Seok Jin; Lee, Sungsoo

    2013-01-01

    OBJECTIVES To evaluate whether the overgrowth of costal cartilage may cause pectus carinatum using three-dimensional (3D) computed tomography (CT). METHODS Twenty-two patients with asymmetric pectus carinatum were included. The fourth, fifth and sixth ribs and costal cartilages were semi-automatically traced, and their full lengths were measured on three-dimensional CT images using curved multi-planar reformatted (MPR) techniques. The rib length and costal cartilage length, the total combined length of the rib and costal cartilage and the ratio of the cartilage and rib lengths (C/R ratio) in each patient were compared between the protruding side and the opposite side at the levels of the fourth, fifth and sixth ribs. RESULTS The length of the costal cartilage was not different between the more protruded side and the contralateral side (55.8 ± 9.8 mm vs 55.9 ± 9.3 mm at the fourth, 70 ± 10.8 mm vs 71.6 ± 10.8 mm at the fifth and 97.8 ± 13.2 mm vs 99.8 ± 15.5 mm at the sixth; P > 0.05). There were also no significant differences between the lengths of ribs. (265.8 ± 34.9 mm vs 266.3 ± 32.9 mm at the fourth, 279.7 ± 32.7 mm vs 280.6 ± 32.4 mm at the fifth and 283.8 ± 33.9 mm vs 283.9 ± 32.3 mm at the sixth; P > 0.05). There was no statistically significant difference in either the total length of rib and costal cartilage or the C/R ratio according to side of the chest (P > 0.05). CONCLUSIONS In patients with asymmetric pectus carinatum, the lengths of the fourth, fifth and sixth costal cartilage on the more protruded side were not different from those on the contralateral side. These findings suggest that overgrowth of costal cartilage cannot explain the asymmetric protrusion of anterior chest wall and may not be the main cause of pectus carinatum. PMID:23868604

  18. Does overgrowth of costal cartilage cause pectus carinatum? A three-dimensional computed tomography evaluation of rib length and costal cartilage length in patients with asymmetric pectus carinatum.

    PubMed

    Park, Chul Hwan; Kim, Tae Hoon; Haam, Seok Jin; Lee, Sungsoo

    2013-11-01

    To evaluate whether the overgrowth of costal cartilage may cause pectus carinatum using three-dimensional (3D) computed tomography (CT). Twenty-two patients with asymmetric pectus carinatum were included. The fourth, fifth and sixth ribs and costal cartilages were semi-automatically traced, and their full lengths were measured on three-dimensional CT images using curved multi-planar reformatted (MPR) techniques. The rib length and costal cartilage length, the total combined length of the rib and costal cartilage and the ratio of the cartilage and rib lengths (C/R ratio) in each patient were compared between the protruding side and the opposite side at the levels of the fourth, fifth and sixth ribs. The length of the costal cartilage was not different between the more protruded side and the contralateral side (55.8 ± 9.8 mm vs 55.9 ± 9.3 mm at the fourth, 70 ± 10.8 mm vs 71.6 ± 10.8 mm at the fifth and 97.8 ± 13.2 mm vs 99.8 ± 15.5 mm at the sixth; P > 0.05). There were also no significant differences between the lengths of ribs. (265.8 ± 34.9 mm vs 266.3 ± 32.9 mm at the fourth, 279.7 ± 32.7 mm vs 280.6 ± 32.4 mm at the fifth and 283.8 ± 33.9 mm vs 283.9 ± 32.3 mm at the sixth; P > 0.05). There was no statistically significant difference in either the total length of rib and costal cartilage or the C/R ratio according to side of the chest (P > 0.05). In patients with asymmetric pectus carinatum, the lengths of the fourth, fifth and sixth costal cartilage on the more protruded side were not different from those on the contralateral side. These findings suggest that overgrowth of costal cartilage cannot explain the asymmetric protrusion of anterior chest wall and may not be the main cause of pectus carinatum.

  19. What is the Difference in Morphologic Features of the Thoracic Pedicle Between Patients With Adolescent Idiopathic Scoliosis and Healthy Subjects? A CT-based Case-control Study.

    PubMed

    Gao, Bo; Gao, Wenjie; Chen, Chong; Wang, Qinghua; Lin, Shaochun; Xu, Caixia; Huang, Dongsheng; Su, Peiqiang

    2017-11-01

    Describing the morphologic features of the thoracic pedicle in patients with adolescent idiopathic scoliosis is necessary for placement of pedicle screws. Previous studies showed inadequate reliability owing to small sample size and heterogeneity of the patients surveyed. To use CT scans (1) to describe the morphologic features of 2718 thoracic pedicles from 60 female patients with Lenke Type 1 adolescent idiopathic scoliosis and 60 age-, sex-, and height-matched controls; and (2) to classify the pedicles in three types based on pedicle width and analyze the distribution of each type. A total of 2718 pedicles from 60 female patients with Lenke Type 1 adolescent idiopathic scoliosis and 60 matched female controls were analyzed via CT. All patients surveyed were diagnosed with adolescent idiopathic scoliosis, Lenke Type 1, at the First Affiliated Hospital of Sun Yat-sen University, and all underwent pedicle screw fixation between January 2008 and December 2013 with preoperative radiographs and CT images on file. We routinely obtained CT scans before these procedures; all patients who underwent surgery during that period had CT scans, and all were available for analysis here. Control subjects had CT scans for other clinical indications and had no abnormal findings of the spine. The control subjects were chosen to match patients in terms of age (15 ± 2.6 years versus 15 ± 2.6 years) and sex. Height of the two groups also was matched (154 ± 9 cm versus 155 ± 10 cm; mean difference, -1.06 cm; 95% CI, -1.24 to -0.81 cm; p < 0.001). Pedicle width and length were measured from T1 to T12. The thoracic spine was classified in four regions: apical vertebra in the structural curve (AV-SC), nonapical vertebra in the structural curve (NAV-SC), apical vertebra in the nonstructural curve (AV-NSC), and nonapical vertebra in the nonstructural curve (NAV-NSC). Pedicles were classified in three types: pedicle width less than 2 mm as Type I, 2 mm to 4 mm as Type II, and greater than 4 mm as Type III. Types I and II were defined as dysplastic pedicles. Paired t test, independent samples t test, one-way ANOVA, followed by Bonferroni's post hoc test and chi-square or Fisher's exact tests were used for statistical comparisons between patients and controls, as appropriate. No difference was found between pedicle width on the convex side (PWv) and in controls (PWn), but pedicle width on the concave side (PWc) (4.99 ± 1.87 mm) was found to be narrower than PWv (6 ± 1.66 mm) and PWn (6 ± 1.45 mm). The variation degree of pedicle width (VDPW) was greatest in the AV-SC region (34% ± 37%), in comparison to AV-NSC (20% ± 25%) (mean difference, 14%; 95% CI, 1.15%-27%; p = 0.025), NAV-SC (17% ± 30%) (mean difference, 17%; 95% CI, 7%-27%; p < 0.001), and NAV-NSC (11% ± 24%) (mean difference, 24%; 95% CI, 13%-34%; p < 0.001). Dysplastic pedicles appeared more in patients with adolescent idiopathic scoliosis (22%; 293 of 1322) compared with controls (13%; 178 of 1396) (odds ratio [OR] = 0.51; 95% CI, 0.42-0.63; p < 0.001). In patients with adolescent idiopathic scoliosis, they commonly occurred on the concave side 34% (228 of 661) and on the AV-SC region (32%; 43 of 136). Pedicle width on the concave side was narrower than pedicle width on the convex side and pedicle width in healthy control subjects. The apical vertebra in the structural curve was the most variegated region of the curve with the highest prevalence of dysplastic pedicles. Our study can help surgeons perform preoperative assessments in females with adolescent idiopathic scoliosis, and with preoperative and intraoperative management for difficult pedicle screw placement. In particular, our results suggest that surgeons should exercise increased vigilance when selecting pedicle screw dimensions, especially in the concave aspect of the mid-thoracic curve, to avoid cortical breeches. Future studies should evaluate other Lenke types of adolescent idiopathic scoliosis, and males with adolescent idiopathic scoliosis.

  20. [A case of traumatic middle meningeal arteriovenous fistula on the side of the head opposite to the injured side].

    PubMed

    Takeuchi, Satoru; Takasato, Yoshio; Masaoka, Hiroyuki; Hayakawa, Takanori; Otani, Naoki; Yoshino, Yoshikazu; Yatsushige, Hiroshi; Sugawara, Takashi; Aoyagi, Chikashi; Suzuki, Go

    2009-10-01

    A rare case of a traumatic middle meningeal arteriovenous fistula on the side of the head opposite to the injured side was reported. A 21-year-old man was admitted to our hospital after a traffic accident in which the right side of his head was hit. CT scans and MR images on admission showed a right temporal bone fracture, traumatic subarachnoid hemorrhage, and a left frontal lobe contusion. Three months after the head injury, he complained of tinnitus and exophthalmos. One year after the head injury, left external carotid angiograms showed a dural arteriovenous fistula fed by the left dilated middle meningeal artery and draining into the middle meningeal vein. Early filling of the sphenoparietal sinus, cavernous sinus, superior ophthalmic vein, and the cortical vein were also detected. Transarterial embolization of the left middle meningeal fistula was performed, resulting in the disappearance of the lesion. The postoperative course was uneventful.

  1. Medical Approach to Right Colon Diverticulitis with Perforation.

    PubMed

    Espinosa, James; Sharma, Rahul; Lucerna, Alan; Stranges, Doug

    2017-01-01

    We report a case of a 71-year-old female who presented with right lower quadrant (RLQ) abdominal pain and was diagnosed on CT scan with right-sided diverticulitis with perforation. She was admitted under the surgical service after consultation and received intravenous fluids, intravenous antibiotics, and pain medications as needed. The patient was discharged 2 days after admission in stable condition with follow-up with gastroenterology. The differential diagnosis of right lower quadrant abdominal pain is vast. Right-sided diverticulitis often presents in a manner similar to appendicitis. In the absence of peritonitis, conservative treatment may be possible. It is predictable that as the population ages, the incidence of right-sided diverticular disease will increase and will result in more presentations of acute right-sided diverticulitis to the emergency department (ED). The aim of this case report is to increase awareness of the incidence, pathophysiology, presentation, work-up (laboratory studies and imaging), and management (medical and surgical) of right-sided diverticulitis among emergency physicians.

  2. Evaluation of GMI and PMI diffeomorphic‐based demons algorithms for aligning PET and CT Images

    PubMed Central

    Yang, Juan; Zhang, You; Yin, Yong

    2015-01-01

    Fusion of anatomic information in computed tomography (CT) and functional information in F18‐FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined F18‐FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole‐body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)‐based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point‐wise mutual information (PMI) diffeomorphic‐based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB‐approved study. Whole‐body PET and CT images were acquired from a combined F18‐FDG PET/CT scanner for each patient. The modified Hausdorff distance (dMH) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of dMH were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI‐based demons and the PMI diffeomorphic‐based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined F18‐FDG PET/CT scanner was used for image acquisition. The PMI diffeomorphic‐based demons algorithm was more accurate than the GMI‐based demons algorithm in registering PET/CT esophageal images. PACS numbers: 87.57.nj, 87.57. Q‐, 87.57.uk PMID:26218993

  3. Evaluation of GMI and PMI diffeomorphic-based demons algorithms for aligning PET and CT Images.

    PubMed

    Yang, Juan; Wang, Hongjun; Zhang, You; Yin, Yong

    2015-07-08

    Fusion of anatomic information in computed tomography (CT) and functional information in 18F-FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined 18F-FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole-body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)-based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point-wise mutual information (PMI) diffeomorphic-based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB-approved study. Whole-body PET and CT images were acquired from a combined 18F-FDG PET/CT scanner for each patient. The modified Hausdorff distance (d(MH)) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of d(MH) were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI-based demons and the PMI diffeomorphic-based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined 18F-FDG PET/CT scanner was used for image acquisition. The PMI diffeomorphic-based demons algorithm was more accurate than the GMI-based demons algorithm in registering PET/CT esophageal images.

  4. 78 FR 19489 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-01

    ... announced below concerns Low Dose CT Lung Cancer Screening: Informed Decision Making and Smoking Cessation... include the initial review, discussion, and evaluation of ``Low Dose CT Lung Cancer Screening: Informed...

  5. Radiation dose in the thyroid and the thyroid cancer risk attributable to CT scans for pediatric patients in one general hospital of China.

    PubMed

    Su, Yin-Ping; Niu, Hao-Wei; Chen, Jun-Bo; Fu, Ying-Hua; Xiao, Guo-Bing; Sun, Quan-Fu

    2014-03-07

    To quantify the radiation dose in the thyroid attributable to different CT scans and to estimate the thyroid cancer risk in pediatric patients. The information about pediatric patients who underwent CT scans was abstracted from the radiology information system in one general hospital between 1 January 2012 and 31 December 2012. The radiation doses were calculated using the ImPACT Patient Dosimetry Calculator and the lifetime attributable risk (LAR) of thyroid cancer incidence was estimated based on the National Academies Biologic Effects of Ionizing Radiation VII model. The subjects comprised 922 children, 68% were males, and received 971 CT scans. The range of typical radiation dose to the thyroid was estimated to be 0.61-0.92 mGy for paranasal sinus CT scans, 1.10-2.45 mGy for head CT scans, and 2.63-5.76 mGy for chest CT scans. The LAR of thyroid cancer were as follows: for head CT, 1.1 per 100,000 for boys and 8.7 per 100,000 for girls; for paranasal sinus CT scans, 0.4 per 100,000 for boys and 2.7 per 100,000 for girls; for chest CT scans, 2.2 per 100,000 for boys and 14.2 per 100,000 for girls. The risk of thyroid cancer was substantially higher for girls than for the boys, and from chest CT scans was higher than that from head or paransal sinus CT scans. Chest CT scans caused higher thyroid dose and the LAR of thyroid cancer incidence, compared with paransal sinus or head CT scans. Therefore, physicians should pay more attention to protect the thyroid when children underwent CT scans, especially chest CT scans.

  6. On NMR prediction of the effectiveness of p-phenylenediamine antioxidants

    NASA Astrophysics Data System (ADS)

    Puškárová, Ingrid; Šoral, Michal; Breza, Martin

    2015-10-01

    NMR shifts of N-phenyl-N‧-alkyl-p-phenylenediamines (PPD) in DMSO have been measured as well as evaluated by B3LYP calculations. According to Simon et al. Molar Antioxidant Effectiveness (AEM) of PPD antioxidants depends on the bond strength of hydrogens to amine nitrogens between aromatic rings (NA), to the side aliphatic chain nitrogens (NB) and to its neighboring tertiary carbon atoms (CT). AEM increases with NMR shifts of HA, HB, NA and probably also of CT atoms whereas NMR shifts of NB atoms exhibit a reverse trend. This is very surprising because similar reactions at A and B sites are supposed.

  7. Assessment of anterior shoulder instability by CT arthrography.

    PubMed

    Yang, S O; Cho, K J; Kim, M J; Ro, I W

    1987-09-01

    Computed tomography (CT) immediately after double-contrast shoulder arthrography was taken in twenty-two young male patients with anterior shoulder instability including recurrent dislocation and subluxation. This recently developed technique called CT arthrography can provide significant information about patients with glenohumeral instability which is difficult to obtain by conventional arthrography. Information about glenoid labrum pathology is useful for proper management of the shoulder with instability. Lesions identified in this study include anterior labral defects (attenuation, tear, displacement), anterior capsular distension and/or detachment, Hill-Sachs lesion, anterior glenoid rim compression fracture, and fracture of scapula. This article describes the method used in CT arthrography of the glenohumeral joint, reviews the normal cross-sectional anatomy, and emphasizes the importance of the application of CT arthrography in the shoulder disorder with instability. CT arthrography of the glenohumeral joint is easy to perform, is accurate, and has lower radiation dose than arthrotomography.

  8. Energy-Discriminative Performance of a Spectral Micro-CT System

    PubMed Central

    He, Peng; Yu, Hengyong; Bennett, James; Ronaldson, Paul; Zainon, Rafidah; Butler, Anthony; Butler, Phil; Wei, Biao; Wang, Ge

    2013-01-01

    Experiments were performed to evaluate the energy-discriminative performance of a spectral (multi-energy) micro-CT system. The system, designed by MARS (Medipix All Resolution System) Bio-Imaging Ltd. (Christchurch, New Zealand), employs a photon-counting energy-discriminative detector technology developed by CERN (European Organization for Nuclear Research). We used the K-edge attenuation characteristic of some known materials to calibrate the detector’s photon energy discrimination. For tomographic analysis, we used the compressed sensing (CS) based ordered-subset simultaneous algebraic reconstruction techniques (OS-SART) to reconstruct sample images, which is effective to reduce noise and suppress artifacts. Unlike conventional CT, the principal component analysis (PCA) method can be applied to extract and quantify additional attenuation information from a spectral CT dataset. Our results show that the spectral CT has a good energy-discriminative performance and provides more attenuation information than the conventional CT. PMID:24004864

  9. SU-E-J-55: End-To-End Effectiveness Analysis of 3D Surface Image Guided Voluntary Breath-Holding Radiotherapy for Left Breast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, M; Feigenberg, S

    Purpose To evaluate the effectiveness of using 3D-surface-image to guide breath-holding (BH) left-side breast treatment. Methods Two 3D surface image guided BH procedures were implemented and evaluated: normal-BH, taking BH at a comfortable level, and deep-inspiration-breath-holding (DIBH). A total of 20 patients (10 Normal-BH and 10 DIBH) were recruited. Patients received a BH evaluation using a commercialized 3D-surface- tracking-system (VisionRT, London, UK) to quantify the reproducibility of BH positions prior to CT scan. Tangential 3D/IMRT plans were conducted. Patients were initially setup under free-breathing (FB) condition using the FB surface obtained from the untaged CT to ensure a correct patientmore » position. Patients were then guided to reach the planned BH position using the BH surface obtained from the BH CT. Action-levels were set at each phase of treatment process based on the information provided by the 3D-surface-tracking-system for proper interventions (eliminate/re-setup/ re-coaching). We reviewed the frequency of interventions to evaluate its effectiveness. The FB-CBCT and port-film were utilized to evaluate the accuracy of 3D-surface-guided setups. Results 25% of BH candidates with BH positioning uncertainty > 2mm are eliminated prior to CT scan. For >90% of fractions, based on the setup deltas from3D-surface-trackingsystem, adjustments of patient setup are needed after the initial-setup using laser. 3D-surface-guided-setup accuracy is comparable as CBCT. For the BH guidance, frequency of interventions (a re-coaching/re-setup) is 40%(Normal-BH)/91%(DIBH) of treatments for the first 5-fractions and then drops to 16%(Normal-BH)/46%(DIBH). The necessity of re-setup is highly patient-specific for Normal-BH but highly random among patients for DIBH. Overall, a −0.8±2.4 mm accuracy of the anterior pericardial shadow position was achieved. Conclusion 3D-surface-image technology provides effective intervention to the treatment process and ensures favorable day-to-day setup accuracy. DIBH setup appears to be more uncertain and this would be the patient group who will definitely benefit from the extra information of 3D surface setup.« less

  10. A collaborative framework for contributing DICOM RT PHI (Protected Health Information) to augment data mining in clinical decision support

    NASA Astrophysics Data System (ADS)

    Deshpande, Ruchi; Thuptimdang, Wanwara; DeMarco, John; Liu, Brent J.

    2014-03-01

    We have built a decision support system that provides recommendations for customizing radiation therapy treatment plans, based on patient models generated from a database of retrospective planning data. This database consists of relevant metadata and information derived from the following DICOM objects - CT images, RT Structure Set, RT Dose and RT Plan. The usefulness and accuracy of such patient models partly depends on the sample size of the learning data set. Our current goal is to increase this sample size by expanding our decision support system into a collaborative framework to include contributions from multiple collaborators. Potential collaborators are often reluctant to upload even anonymized patient files to repositories outside their local organizational network in order to avoid any conflicts with HIPAA Privacy and Security Rules. We have circumvented this problem by developing a tool that can parse DICOM files on the client's side and extract de-identified numeric and text data from DICOM RT headers for uploading to a centralized system. As a result, the DICOM files containing PHI remain local to the client side. This is a novel workflow that results in adding only relevant yet valuable data from DICOM files to the centralized decision support knowledge base in such a way that the DICOM files never leave the contributor's local workstation in a cloud-based environment. Such a workflow serves to encourage clinicians to contribute data for research endeavors by ensuring protection of electronic patient data.

  11. Indication for Computed Tomography Scan in Shoulder Instability: Sensitivity and Specificity of Standard Radiographs to Predict Bone Defects After Traumatic Anterior Glenohumeral Instability.

    PubMed

    Delage Royle, Audrey; Balg, Frédéric; Bouliane, Martin J; Canet-Silvestri, Fanny; Garant-Saine, Laurianne; Sheps, David M; Lapner, Peter; Rouleau, Dominique M

    2017-10-01

    Quantifying glenohumeral bone loss is key in preoperative surgical planning for a successful Bankart repair. Simple radiographs can accurately measure bone defects in cases of recurrent shoulder instability. Cohort study (diagnosis); Level of evidence, 2. A true anteroposterior (AP) view, alone and in combination with an axillary view, was used to evaluate the diagnostic properties of radiographs compared with computed tomography (CT) scan, the current gold standard, to predict significant bone defects in 70 patients. Sensitivity, specificity, and positive and negative predictive values were evaluated and compared. Detection of glenoid bone loss on plain film radiographs, with and without axillary view, had a sensitivity of 86% for both views and a specificity of 73% and 64% with and without the axillary view, respectively. For detection of humeral bone loss, the sensitivity was 8% and 17% and the specificity was 98% and 91% with and without the axillary view, respectively. Regular radiographs would have missed 1 instance of significant bone loss on the glenoid side and 20 on the humeral side. Interobserver reliabilities were moderate for glenoid detection (κ = 0.473-0.503) and poor for the humeral side (κ = 0.278-0.336). Regular radiographs showed suboptimal sensitivity, specificity, and reliability. Therefore, CT scan should be considered in the treatment algorithm for accurate quantification of bone loss to prevent high rates of recurrent instability.

  12. An open library of CT patient projection data

    NASA Astrophysics Data System (ADS)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Holmes, David; Fletcher, Joel; McCollough, Cynthia

    2016-03-01

    Lack of access to projection data from patient CT scans is a major limitation for development and validation of new reconstruction algorithms. To meet this critical need, we are building a library of CT patient projection data in an open and vendor-neutral format, DICOM-CT-PD, which is an extended DICOM format that contains sinogram data, acquisition geometry, patient information, and pathology identification. The library consists of scans of various types, including head scans, chest scans, abdomen scans, electrocardiogram (ECG)-gated scans, and dual-energy scans. For each scan, three types of data are provided, including DICOM-CT-PD projection data at various dose levels, reconstructed CT images, and a free-form text file. Several instructional documents are provided to help the users extract information from DICOM-CT-PD files, including a dictionary file for the DICOM-CT-PD format, a DICOM-CT-PD reader, and a user manual. Radiologist detection performance based on the reconstructed CT images is also provided. So far 328 head cases, 228 chest cases, and 228 abdomen cases have been collected for potential inclusion. The final library will include a selection of 50 head, chest, and abdomen scans each from at least two different manufacturers, and a few ECG-gated scans and dual-source, dual-energy scans. It will be freely available to academic researchers, and is expected to greatly facilitate the development and validation of CT reconstruction algorithms.

  13. Material Separation Using Dual-Energy CT: Current and Emerging Applications.

    PubMed

    Patino, Manuel; Prochowski, Andrea; Agrawal, Mukta D; Simeone, Frank J; Gupta, Rajiv; Hahn, Peter F; Sahani, Dushyant V

    2016-01-01

    Dual-energy (DE) computed tomography (CT) offers the opportunity to generate material-specific images on the basis of the atomic number Z and the unique mass attenuation coefficient of a particular material at different x-ray energies. Material-specific images provide qualitative and quantitative information about tissue composition and contrast media distribution. The most significant contribution of DE CT-based material characterization comes from the capability to assess iodine distribution through the creation of an image that exclusively shows iodine. These iodine-specific images increase tissue contrast and amplify subtle differences in attenuation between normal and abnormal tissues, improving lesion detection and characterization in the abdomen. In addition, DE CT enables computational removal of iodine influence from a CT image, generating virtual noncontrast images. Several additional materials, including calcium, fat, and uric acid, can be separated, permitting imaging assessment of metabolic imbalances, elemental deficiencies, and abnormal deposition of materials within tissues. The ability to obtain material-specific images from a single, contrast-enhanced CT acquisition can complement the anatomic knowledge with functional information, and may be used to reduce the radiation dose by decreasing the number of phases in a multiphasic CT examination. DE CT also enables generation of energy-specific and virtual monochromatic images. Clinical applications of DE CT leverage both material-specific images and virtual monochromatic images to expand the current role of CT and overcome several limitations of single-energy CT. (©)RSNA, 2016.

  14. The impact of the CartoSound® image directly acquired from the left atrium for integration in atrial fibrillation ablation.

    PubMed

    Kaseno, Kenichi; Hisazaki, Kaori; Nakamura, Kohki; Ikeda, Etsuko; Hasegawa, Kanae; Aoyama, Daisetsu; Shiomi, Yuichiro; Ikeda, Hiroyuki; Morishita, Tetsuji; Ishida, Kentaro; Amaya, Naoki; Uzui, Hiroyasu; Tada, Hiroshi

    2018-04-14

    Intracardiac echocardiographic (ICE) imaging might be useful for integrating three-dimensional computed tomographic (CT) images for left atrial (LA) catheter navigation during atrial fibrillation (AF) ablation. However, the optimal CT image integration method using ICE has not been established. This study included 52 AF patients who underwent successful circumferential pulmonary vein isolation (CPVI). In all patients, CT image integration was performed after the CPVI with the following two methods: (1) using ICE images of the LA derived from the right atrium and right ventricular outflow tract (RA-merge) and (2) using ICE images of the LA directly derived from the LA added to the image for the RA-merge (LA-merge). The accuracy of these two methods was assessed by the distances between the integrated CT image and ICE image (ICE-to-CT distance), and between the CT image and actual ablated sites for the CPVI (CT-to-ABL distance). The mean ICE-to-CT distance was comparable between the two methods (RA-merge = 1.6 ± 0.5 mm, LA-merge = 1.7 ± 0.4 mm; p = 0.33). However, the mean CT-to-ABL distance was shorter for the LA-merge (2.1 ± 0.6 mm) than RA-merge (2.5 ± 0.8 mm; p < 0.01). The LA, especially the left-sided PVs and LA roof, was more sharply delineated by direct LA imaging, and whereas the greatest CT-to-ABL distance was observed at the roof portion of the left superior PV (3.7 ± 2.8 mm) after the RA-merge, it improved to 2.6 ± 1.9 mm after the LA-merge (p < 0.01). Additional ICE images of the LA directly acquired from the LA might lead to a greater accuracy of the CT image integration for the CVPI.

  15. A mass that has no (EBUS) echo.

    PubMed

    Rosenblum, Matthew K; Wang, Sue X; Seeley, Eric J

    2018-01-01

    We report findings for a patient that underwent endobronchial ultrasound (EBUS) guided transbronchial needle aspiration (TBNA) for diagnostic purposes after an abnormal chest CT. The patient initially presented with cough and shortness of breath. Chest CT revealed a 6 cm soft tissue mass with mildly enlarged right hilar lymph nodes (LNs) and a small right sided pleural effusion. Based on these radiologic findings, the patient underwent an EBUS guided FNA of the mass. To our surprise, the mass was hypoechoic by EBUS and on aspiration, the syringe filled with yellow fluid. This finding in combination with a re-review of the CT scans with a special focus on the Hounsfield Units of the lesion confirmed the diagnosis of a mediastinal bronchogenic cyst. This case demonstrates the role of Hounsfield units in analyzing mediastinal masses and highlights the effectiveness of EBUS guided TBNA in diagnosis and treatment of bronchogenic cysts.

  16. Chest pain in a young patient: an unusual complication of Epstein-Barr virus.

    PubMed

    Raman, Lavanya; Rathod, Krishnaraj Sinhji; Banka, Rajesh

    2014-03-31

    A 29-year-old man presented with sudden left-sided pleuritic chest pain on a background of sore throat during the preceding week. On examination he had tender cervical lymphadenopathy, he was tachycardic and had a 24 mm Hg blood pressure difference between the left and right arms. Bloods revealed deranged liver function tests and a lymphocytosis. His D-dimer was raised, hence he was treated for presumed pulmonary embolism before imaging was available. Monospot test was positive. He subsequently had both a CT pulmonary angiogram and a CT angiogram of the aorta to exclude pulmonary embolism and aortic dissection. The CT revealed splenomegaly with a large subdiaphragmatic haematoma secondary to splenic rupture. This had likely caused referred pain through diaphragmatic irritation. He was taken to theatre for urgent splenectomy. The unifying diagnosis was infectious mononucleosis complicated by spontaneous splenic rupture secondary to Epstein-Barr virus infection.

  17. 20. View of sand filtration bed. Wheelbarrow was used to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. View of sand filtration bed. Wheelbarrow was used to remove schmutzdeck (top, dirty sand layer containing particulate contamination, dead microorganisms and debris) for cleaning and or disposal. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  18. 27. Detail view of mechanical float gages used to monitor ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. Detail view of mechanical float gages used to monitor level of water in the filtration bed reservoir. Gage on left measures water head, gage on right monitors filtration rate. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  19. Aerodynamic and Nonlinear Dynamic Acoustic Analysis of Tension Asymmetry in Excised Canine Larynges

    ERIC Educational Resources Information Center

    Devine, Erin E.; Bulleit, Erin E.; Hoffman, Matthew R.; McCulloch, Timothy M.; Jiang, Jack J.

    2012-01-01

    Purpose: To model tension asymmetry caused by superior laryngeal nerve paralysis (SLNP) in excised larynges and apply perturbation, nonlinear dynamic, and aerodynamic analyses. Method: SLNP was modeled in 8 excised larynges using sutures and weights to mimic cricothyroid (CT) muscle function. Weights were removed from one side to create tension…

  20. [Imaging analysis of jaw defects reparation with antigen-extracted porcine cancellous bone].

    PubMed

    Chen, Xufeng; Lu, Lihong; Feng, Zhiqiang; Yin, Zhongda; Lai, Renfa

    2017-12-01

    At present, most of the bone xenograft for clinical application comes from bovine. In recent years, many studies have been done on the clinical application of porcine xenograft bone. The goal of this study was to evaluate the effect of canine mandibular defects reparation with antigen-extracted porcine cancellous bone by imaging examination. Four dogs' bilateral mandibular defects were created, with one side repaired with autologous bone (set as control group) while the other side repaired with antigen-extracted porcine cancellous bone (set as experimental group). Titanium plates and titanium screws were used for fixation. Cone beam computed tomography (CBCT), computed tomography (CT), single-photon emission computed tomography (SPECT) were undertaken at week 12 and 24 postoperatively, and SPECT and CT images were fused. The results demonstrated that the remodeling of antigen-extracted porcine cancellous bone was slower than that of autologous bone, but it can still be used as scaffold for jaw defects. The results in this study provide a new choice for materials required for clinical reparation of jaw defects.

  1. Thyroid gland rupture caused by blunt trauma to the neck.

    PubMed

    Hara, Hirotaka; Hirose, Yoshinobu; Yamashita, Hiroshi

    2016-02-19

    Thyroid rupture following blunt trauma is extremely rare, and neck pain without swelling may be the only presenting symptom. However, hemorrhage and hematoma subsequently causes severe tracheal compression and respiratory distress. A 71-year-old Japanese woman visited our emergency room with a complaint of increasing right-sided neck pain at the thyroid cartilage level after she tripped and accidentally hit her neck against a pole 3 h back. On admission, her vital signs were stable. There was no swelling or subcutaneous emphysema. Laryngeal endoscopy revealed mild laryngeal edema, although there was no impairment in vocal fold mobility on either side. Contrast-enhanced computed tomography (CT) revealed rupture of the right lobe of the thyroid gland accompanied by a large hematoma extending from the neck to the mediastinum. Under general anesthesia, the right lobe was resected and the hematoma was evacuated. Only a few isolated cases of thyroid rupture caused by blunt neck trauma have been reported in patients with normal thyroid glands and neck pain without swelling may be the only presenting symptom. When suspected, CT should be performed to confirm the diagnosis determine the optimal treatment.

  2. Quantitative impact of pediatric sinus surgery on facial growth.

    PubMed

    Senior, B; Wirtschafter, A; Mai, C; Becker, C; Belenky, W

    2000-11-01

    To quantitatively evaluate the long-term impact of sinus surgery on paranasal sinus development in the pediatric patient. Longitudinal review of eight pediatric patients treated with unilateral sinus surgery for periorbital or orbital cellulitis with an average follow-up of 6.9 years. Control subjects consisted of two groups, 9 normal adult patients with no computed tomographic evidence of sinusitis and 10 adult patients with scans consistent with sinusitis and a history of sinus-related symptoms extending to childhood. Application of computed tomography (CT) volumetrics, a technique allowing for precise calculation of volumes using thinly cut CT images, to the study and control groups. Paired Student t test analyses of side-to-side volume comparisons in the normal patients, patients with sinusitis, and patients who had surgery revealed no statistically significant differences. Comparisons between the orbital volumes of patients who did and did not have surgery revealed a statistically significant increase in orbital volume in patients who had surgery. Only minimal changes in facial volume measurements have been found, confirming clinical impressions that sinus surgery in children is safe and without significant cosmetic sequelae.

  3. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 4. Medical Imaging Procedures.

    PubMed

    Byrum, Russell; Keith, Lauren; Bartos, Christopher; St Claire, Marisa; Lackemeyer, Matthew G; Holbrook, Michael R; Janosko, Krisztina; Barr, Jason; Pusl, Daniela; Bollinger, Laura; Wada, Jiro; Coe, Linda; Hensley, Lisa E; Jahrling, Peter B; Kuhn, Jens H; Lentz, Margaret R

    2016-10-03

    Medical imaging using animal models for human diseases has been utilized for decades; however, until recently, medical imaging of diseases induced by high-consequence pathogens has not been possible. In 2014, the National Institutes of Health, National Institute of Allergy and Infectious Diseases, Integrated Research Facility at Fort Detrick opened an Animal Biosafety Level 4 (ABSL-4) facility to assess the clinical course and pathology of infectious diseases in experimentally infected animals. Multiple imaging modalities including computed tomography (CT), magnetic resonance imaging, positron emission tomography, and single photon emission computed tomography are available to researchers for these evaluations. The focus of this article is to describe the workflow for safely obtaining a CT image of a live guinea pig in an ABSL-4 facility. These procedures include animal handling, anesthesia, and preparing and monitoring the animal until recovery from sedation. We will also discuss preparing the imaging equipment, performing quality checks, communication methods from "hot side" (containing pathogens) to "cold side," and moving the animal from the holding room to the imaging suite.

  4. MPR-CT Imaging for Stapes Prosthesis: Accuracy and Clinical Significance.

    PubMed

    Fang, Yanqing; Wang, Bing; Galvin, John J; Tao, Duoduo; Deng, Rui; Ou, Xiong; Liu, Yangwenyi; Dai, Peidong; Sha, Yan; Zhang, Tianyu; Chen, Bing

    2016-04-01

    The aims of this article are: 1) to re-evaluate the accuracy of multiple planar reconstruction computed tomography (MPR-CT) imaging on stapes-prosthesis parameters, and 2) to clarify possible relationships between prosthesis intravestibular depth and postoperative hearing outcomes. Seventy patients (46 women and 24 men; 32 right and 38 left sides) with the mean age of 40 years (range, 19-62 yr) with clinical otosclerosis. All patients underwent stapedotomy and were implanted with the same type of titanium piston prosthesis by the same surgeon. Postoperative MPR-CTs were obtained at patients' follow-up visits. The length and intravestibular depth of the stapes prosthesis (including absolute and relative depth) were calculated from the MPR-CT imaging. Relationships between the intravestibular depth of the prosthesis and hearing outcomes (pre- and postoperative audiograms) were analyzed using Spearman correlation analyses. The length of the prosthesis was overestimated by 1.8% (0.1 mm) by the MPR-CT imaging. Axial and coronal measurements were significantly correlated (p < 0.05). There was great intersubject variability in hearing outcomes differed insignificantly, regardless of intravestibular depth within the security range. No relationships were found between the intravestibular depth of the stapes prosthesis, as measured with MPR-CT, and postoperative hearing results. MPR-CT can provide an accurate estimation of stapes prosthesis parameters. However, the prosthesis intravestibular depth did not seem to affect postoperative hearing outcomes.

  5. Generalized Lymph Node Activation after Influenza Vaccination on 18F FDG-PET/CT Imaging, an Important Pitfall in PET Interpretation.

    PubMed

    Ayati, Narjess; Jesudason, Sarah; Berlangieri, Salvatore U; Scott, Andrew M

    2017-01-01

    We report on a 59-year-old female patient with an infected vascular graft investigated with 18 F FDG-PET/CT. The first of two studies showed FDG activity in the left deltoid and ipsilateral axillary lymph nodes explained by influenza vaccination the day prior. The second 18 F FDG-PET/CT showed multiple FDG-avid lymph nodes on both sides of the diaphragm without tracer accumulation at the vaccination site. Three months later the CT was negative for lymphadenopathy within the chest or abdominal region. Although influenza vaccination is a potential source of false positive results in FDG PET studies, generalised lymph node activation post vaccination is a rare finding with only one prior published report in individuals infected with HIV-1. This case emphasizes the necessity of taking a history of vaccination prior to a FDG PET study, and consideration of a vaccine-related immune response even without evidence of tracer activity at the vaccination site when generalised FDG-avid lymphadenopathy is encountered.

  6. Structural analyses and yeast production of the β-1,3-1,4-glucanase catalytic module encoded by the licB gene of Clostridium thermocellum.

    PubMed

    Chen, Chun-Chi; Huang, Jian-Wen; Zhao, Puya; Ko, Tzu-Ping; Huang, Chun-Hsiang; Chan, Hsiu-Chien; Huang, Zhiyong; Liu, Wenting; Cheng, Ya-Shan; Liu, Je-Ruei; Guo, Rey-Ting

    2015-04-01

    A thermophilic glycoside hydrolase family 16 (GH16) β-1,3-1,4-glucanase from Clostridium thermocellum (CtLic16A) holds great potentials in industrial applications due to its high specific activity and outstanding thermostability. In order to understand its molecular machinery, the crystal structure of CtLic16A was determined to 1.95Å resolution. The enzyme folds into a classic GH16 β-jellyroll architecture which consists of two β-sheets atop each other, with the substrate-binding cleft lying on the concave side of the inner β-sheet. Two Bis-Tris propane molecules were found in the positive and negative substrate binding sites. Structural analysis suggests that the major differences between the CtLic16A and other GH16 β-1,3-1,4-glucanase structures occur at the protein exterior. Furthermore, the high catalytic efficacy and thermal profile of the CtLic16A are preserved in the enzyme produced in Pichia pastoris, encouraging its further commercial applications. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Improving students’ mathematical critical thinking through rigorous teaching and learning model with informal argument

    NASA Astrophysics Data System (ADS)

    Hamid, H.

    2018-01-01

    The purpose of this study is to analyze an improvement of students’ mathematical critical thinking (CT) ability in Real Analysis course by using Rigorous Teaching and Learning (RTL) model with informal argument. In addition, this research also attempted to understand students’ CT on their initial mathematical ability (IMA). This study was conducted at a private university in academic year 2015/2016. The study employed the quasi-experimental method with pretest-posttest control group design. The participants of the study were 83 students in which 43 students were in the experimental group and 40 students were in the control group. The finding of the study showed that students in experimental group outperformed students in control group on mathematical CT ability based on their IMA (high, medium, low) in learning Real Analysis. In addition, based on medium IMA the improvement of mathematical CT ability of students who were exposed to RTL model with informal argument was greater than that of students who were exposed to CI (conventional instruction). There was also no effect of interaction between RTL model and CI model with both (high, medium, and low) IMA increased mathematical CT ability. Finally, based on (high, medium, and low) IMA there was a significant improvement in the achievement of all indicators of mathematical CT ability of students who were exposed to RTL model with informal argument than that of students who were exposed to CI.

  8. Compressed Sensing mm-Wave SAR for Non-Destructive Testing Applications Using Multiple Weighted Side Information.

    PubMed

    Becquaert, Mathias; Cristofani, Edison; Van Luong, Huynh; Vandewal, Marijke; Stiens, Johan; Deligiannis, Nikos

    2018-05-31

    This work explores an innovative strategy for increasing the efficiency of compressed sensing applied on mm-wave SAR sensing using multiple weighted side information. The approach is tested on synthetic and on real non-destructive testing measurements performed on a 3D-printed object with defects while taking advantage of multiple previous SAR images of the object with different degrees of similarity. The tested algorithm attributes autonomously weights to the side information at two levels: (1) between the components inside the side information and (2) between the different side information. The reconstruction is thereby almost immune to poor quality side information while exploiting the relevant components hidden inside the added side information. The presented results prove that, in contrast to common compressed sensing, good SAR image reconstruction is achieved at subsampling rates far below the Nyquist rate. Moreover, the algorithm is shown to be much more robust for low quality side information compared to coherent background subtraction.

  9. Non-rigid registration between 3D ultrasound and CT images of the liver based on intensity and gradient information

    NASA Astrophysics Data System (ADS)

    Lee, Duhgoon; Nam, Woo Hyun; Lee, Jae Young; Ra, Jong Beom

    2011-01-01

    In order to utilize both ultrasound (US) and computed tomography (CT) images of the liver concurrently for medical applications such as diagnosis and image-guided intervention, non-rigid registration between these two types of images is an essential step, as local deformation between US and CT images exists due to the different respiratory phases involved and due to the probe pressure that occurs in US imaging. This paper introduces a voxel-based non-rigid registration algorithm between the 3D B-mode US and CT images of the liver. In the proposed algorithm, to improve the registration accuracy, we utilize the surface information of the liver and gallbladder in addition to the information of the vessels inside the liver. For an effective correlation between US and CT images, we treat those anatomical regions separately according to their characteristics in US and CT images. Based on a novel objective function using a 3D joint histogram of the intensity and gradient information, vessel-based non-rigid registration is followed by surface-based non-rigid registration in sequence, which improves the registration accuracy. The proposed algorithm is tested for ten clinical datasets and quantitative evaluations are conducted. Experimental results show that the registration error between anatomical features of US and CT images is less than 2 mm on average, even with local deformation due to different respiratory phases and probe pressure. In addition, the lesion registration error is less than 3 mm on average with a maximum of 4.5 mm that is considered acceptable for clinical applications.

  10. Correlation between the extent of pneumatization of Agger agger Nasi nasi cells and the anterior-to-posterior length of the frontal recess: A a computer-assisted anatomical study.

    PubMed

    Altıntaş, Ahmet; Çelik, Mustafa; Yegin, Yakup; Canpolat, Sinan; Olgun, Burak; Tülin Kayhan, Fatma

    2017-06-30

    To explore the correlation between the volume of the aAgger nNasi (AN) cell bulge and the A-P length of the frontal recess (FR). In total, 120 patients, who underwent septoplasty, were included. All patients underwent preoperative paranasal sinus computed tomography of the paranasal sinuses (PNS CT) imaging. In total, CT data on of all 120 PNSs patients were analyzed in terms of thewith respect to the extent of pneumatization of the AN cell bulge and the A-P dimensions of the FR. Each side was analyzed separately. We included 120 patients,: 78 (65.0%) females and 42 (35.0 %) males. Their average age was 33.7 ± 11.6 years (range: 18-65 years). The mean volume of the AN cell bulge was 0.26 ± 0.4 mm3 on both the right and left sides. The A-P length of the FR was 7.7 ± 2.2 mm. No significant between-side difference in the mean volume of the AN cell bulge was apparent observed (p=0.906). This volume did not differ significantly by age or sex (p=0.844 and p=0.971, respectively). We found no correlation between the volume of the AN cell bulge and the A-P length of the FR (r = 0.098, p=0.192). In the present study, no correlation between AN cell volume and the A-P length of the FR was found. When studying the anatomical complexity of the FR, it is essential to consider the AN cell volume. We suggest that preoperative CT imaging is critical when endoscopic sinus surgery is planned. However, further studies with larger numbers of patients are needed to explore the relationship between AN cell pneumatization and the anatomy of the FR.

  11. SU-C-12A-07: Effect of Vertical Position On Dose Reduction Using X-Care

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silosky, M; Marsh, R

    Purpose: Reduction of absorbed dose to radiosensitive tissues is an important goal in diagnostic radiology. Siemens Medical has introduced a technique (X-CARE) to lower CT dose to anterior anatomy by reducing the tube current during 80° of rotation over radiosensitive tissues. Phantom studies have shown 30-40% dose reduction when phantoms are positioned at isocenter. However, for CT face and sinus exams, the center of the head is commonly positioned below isocenter. This work investigated the effects of vertical patient positioning on dose reduction using X-CARE. Methods: A 16cm Computed Tomography Dose Index phantom was scanned on a Siemens Definition Flashmore » CT scanner using a routine head protocol, with the phantom positioned at scanner isocenter. Optically stimulated luminescent dosimeters were placed on the anterior and posterior sides of the phantom. The phantom was lowered in increments of 2cm and rescanned, up to 8cm below isocenter. The experiment was then repeated using the same scan parameters but adding the X-CARE technique. The mean dosimeter counts were determined for each phantom position, and the difference between XCARE and routine scans was plotted as a function of distance from isocenter. Results: With the phantom positioned at isocenter, using XCARE reduced dose to the anterior side of the phantom by 40%, compared to dose when X-CARE was not used. Positioned below isocenter, anterior dose was reduced by only 20-27%. Additionally, using X-CARE at isocenter reduced dose to the anterior portion of the phantom by 45.6% compared to scans performed without X-CARE 8cm below isocenter. Conclusion: While using X-CARE substantially reduced dose to the anterior side of the phantom, this effect was diminished when the phantom was positioned below isocenter, simulating common practice for face and sinus scans. This indicates that centering the head in the gantry will maximize the effect of X-CARE.« less

  12. WE-G-207-07: Iterative CT Shading Correction Method with No Prior Information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, P; Mao, T; Niu, T

    2015-06-15

    Purpose: Shading artifacts are caused by scatter contamination, beam hardening effects and other non-ideal imaging condition. Our Purpose is to propose a novel and general correction framework to eliminate low-frequency shading artifacts in CT imaging (e.g., cone-beam CT, low-kVp CT) without relying on prior information. Methods: Our method applies general knowledge of the relatively uniform CT number distribution in one tissue component. Image segmentation is applied to construct template image where each structure is filled with the same CT number of that specific tissue. By subtracting the ideal template from CT image, the residual from various error sources are generated.more » Since the forward projection is an integration process, the non-continuous low-frequency shading artifacts in the image become continuous and low-frequency signals in the line integral. Residual image is thus forward projected and its line integral is filtered using Savitzky-Golay filter to estimate the error. A compensation map is reconstructed on the error using standard FDK algorithm and added to the original image to obtain the shading corrected one. Since the segmentation is not accurate on shaded CT image, the proposed scheme is iterated until the variation of residual image is minimized. Results: The proposed method is evaluated on a Catphan600 phantom, a pelvic patient and a CT angiography scan for carotid artery assessment. Compared to the one without correction, our method reduces the overall CT number error from >200 HU to be <35 HU and increases the spatial uniformity by a factor of 1.4. Conclusion: We propose an effective iterative algorithm for shading correction in CT imaging. Being different from existing algorithms, our method is only assisted by general anatomical and physical information in CT imaging without relying on prior knowledge. Our method is thus practical and attractive as a general solution to CT shading correction. This work is supported by the National Science Foundation of China (NSFC Grant No. 81201091), National High Technology Research and Development Program of China (863 program, Grant No. 2015AA020917), and Fund Project for Excellent Abroad Scholar Personnel in Science and Technology.« less

  13. TU-H-CAMPUS-IeP3-01: Simultaneous PET Restoration and PET/CT Co-Segmentation Using a Variational Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, L; Tan, S; Lu, W

    Purpose: PET images are usually blurred due to the finite spatial resolution, while CT images suffer from low contrast. Segment a tumor from either a single PET or CT image is thus challenging. To make full use of the complementary information between PET and CT, we propose a novel variational method for simultaneous PET image restoration and PET/CT images co-segmentation. Methods: The proposed model was constructed based on the Γ-convergence approximation of Mumford-Shah (MS) segmentation model for PET/CT co-segmentation. Moreover, a PET de-blur process was integrated into the MS model to improve the segmentation accuracy. An interaction edge constraint termmore » over the two modalities were specially designed to share the complementary information. The energy functional was iteratively optimized using an alternate minimization (AM) algorithm. The performance of the proposed method was validated on ten lung cancer cases and five esophageal cancer cases. The ground truth were manually delineated by an experienced radiation oncologist using the complementary visual features of PET and CT. The segmentation accuracy was evaluated by Dice similarity index (DSI) and volume error (VE). Results: The proposed method achieved an expected restoration result for PET image and satisfactory segmentation results for both PET and CT images. For lung cancer dataset, the average DSI (0.72) increased by 0.17 and 0.40 than single PET and CT segmentation. For esophageal cancer dataset, the average DSI (0.85) increased by 0.07 and 0.43 than single PET and CT segmentation. Conclusion: The proposed method took full advantage of the complementary information from PET and CT images. This work was supported in part by the National Cancer Institute Grants R01CA172638. Shan Tan and Laquan Li were supported in part by the National Natural Science Foundation of China, under Grant Nos. 60971112 and 61375018.« less

  14. 18F-FDG PET/CT in breast cancer: Evidence-based recommendations in initial staging.

    PubMed

    Caresia Aroztegui, Ana Paula; García Vicente, Ana María; Alvarez Ruiz, Soledad; Delgado Bolton, Roberto Carlos; Orcajo Rincon, Javier; Garcia Garzon, Jose Ramon; de Arcocha Torres, Maria; Garcia-Velloso, Maria Jose

    2017-10-01

    Current guidelines do not systematically recommend 18F-FDG PET/CT for breast cancer staging; and the recommendations and level of evidence supporting its use in different groups of patients vary among guidelines. This review summarizes the evidence about the role of 18F-FDG PET/CT in breast cancer staging and the therapeutic and prognostic impact accumulated in the last decade. Other related aspects, such as the association of metabolic information with biology and prognosis are considered and evidence-based recommendations for the use of 18F-FDG PET/CT in breast cancer staging are offered. We systematically searched MEDLINE for articles reporting studies with at least 30 patients related to clinical questions following the Problem/Population, Intervention, Comparison, and Outcome framework. We critically reviewed the selected articles and elaborated evidence tables structuring the summarized information into methodology, results, and limitations. The level of evidence and the grades of recommendation for the use of 18F-FDG PET/CT in different contexts are summarized. Level III evidence supports the use of 18F-FDG PET/CT for initial staging in patients with recently diagnosed breast cancer; the diagnostic and therapeutic impact of the 18F-FDG PET/CT findings is sufficient for a weak recommendation in this population. In patients with locally advanced breast cancer, level II evidence supports the use of 18F-FDG PET/CT for initial staging; the diagnostic and therapeutic impact of the 18F-FDG PET/CT findings is sufficient for a strong recommendation in this population. In patients with recently diagnosed breast cancer, the metabolic information from baseline 18F-FDG PET/CT is associated with tumor biology and has prognostic implications, supported by level II evidence. In conclusion, 18F-FDG PET/CT is not recommended for staging all patients with early breast cancer, although evidence of improved regional and systemic staging supports its use in locally advanced breast cancer. Baseline tumor glycolytic activity is associated with tumor biology and prognosis.

  15. Conjoined twins: implications for blastogenesis.

    PubMed

    Machin, G A

    1993-01-01

    It is difficult to draw sweeping general conclusions about the blastogenesis of CT, principally because so few thoroughly studied cases are reported. It is to be hoped that methods such as painstaking gross or electronic dissection will increase the number of well-documented cases. Nevertheless, the following conclusions can be proposed: 1. Most CT can be classified into a few main anatomic types (or paradigms), and there are also rare transitional types that show gradation between the main types. 2. Most CT have two full notochordal axes (Fig. 5); the ventral organs induced along these axes may be severely disorientated, malformed, or aplastic in the process of being arranged within one body. Reported anatomic types of CT represent those notochordal arrangements that are compatible with reasonably complete embryogenesis. New ventro-lateral axes are formed in many types of CT because of space constriction in the ventral zones. The new structures represent areas of "mutual recognition and organization" rather than "fusion" (Fig. 17). 3. Orientations of the pairs of axes in the embryonic disc can be deduced from the resulting anatomy. Except for dicephalus, the axes are not side by side. Notochords are usually "end-on" or ventro-ventral in orientation (Fig. 5). 4. A single gastrulation event or only partial duplicated gastrulation event seems to occur in dicephalics, despite a full double notochord. 5. The anatomy of diprosopus requires further clarification, particularly in cases with complete crania rather than anencephaly-equivalent. Diprosopus CT offer the best opportunity to study the effects of true forking of the notochord, if this actually occurs. 6. In cephalothoracopagus, thoracopagus, and ischiopagus, remarkably complete new body forms are constructed at right angles to the notochordal axes. The extent of expression of viscera in these types depends on the degree of noncongruity of their ventro-ventral axes (Figs. 4, 11, 15b). 7. Some organs and tissues fail to develop (interaction aplasia) because of conflicting migrational pathways or abnormal concentrations of morphogens in and around the neoaxes. 8. Where the cardiovascular system is discordantly expressed in dicephalus and thoracopagus twins, the right heart is more severely malformed, depending on the degree of interaction of the two embryonic septa transversa. 9. The septum transversum provides mesenchymal components to the heawrt and liver; the epithelial components (derived fro the foregut[s]) may vary in number from the number of mesenchymal septa transversa contributing to the liver of the CT embryo.(ABSTRACT TRUNCATED AT 400 WORDS)

  16. Initial experience of intraoperative three-dimensional navigation for liver resection using real-time virtual sonography.

    PubMed

    Satou, Shouichi; Aoki, Taku; Kaneko, Junichi; Sakamoto, Yoshihiro; Hasegawa, Kiyoshi; Sugawara, Yasuhiko; Arai, Osamu; Mitake, Tsuyoshi; Miura, Koui; Kokudo, Norihiro

    2014-02-01

    Real-time virtual sonography is an innovative imaging technology that detects the spatial position of an ultrasound probe and immediately reconstructs a section of computed tomography (CT) and/or magnetic resonance in accordance with the ultrasound image, thereby allowing a real-time comparison of those modalities. A novel intraoperative navigation system for liver resection using real-time virtual sonography has been devised for the detection of tumors and navigation of the resection plane. Sixteen patients with hepatic malignancies (26 tumors in total) were involved in this study, and the system was used intraoperatively. The tumor size ranged 2 to 140 mm (23 mm in median). By the navigation system, operators could refer intraoperative ultrasound image displayed on the television monitor side-by-side with corresponding images of CT and/or magnetic resonance. In addition, the system overlaid preoperative simulation on the CT image and highlighted the extent of resection so as to navigate the resection plane. Because the system used electromagnetic power in the operation room, the feasibility and safety of the system was investigated as well as its validity. The system could be used uneventfully in each operation. All of the 26 tumors scheduled to be resected were detected by the navigation system. The weight of the resected specimen correlated with the preoperatively simulated volume (R = 0.995, P < .0001). The feasibility and safety of the navigation system were confirmed. The system should be helpful for intraoperative tumor detection and navigation of liver resection.

  17. Assessment of radial torsion using computed tomography in dogs with and without antebrachial limb deformity.

    PubMed

    Kroner, Kevin; Cooley, Katie; Hoey, Seamus; Hetzel, Scott J; Bleedorn, Jason A

    2017-01-01

    To evaluate the reliability of radial torsion assessment in dogs using computed tomography (CT). Cadaveric and retrospective observational clinical study. Thoracic limbs (n = 40) from bilateral normal cadaveric canine specimens (10 pairs) and unilateral antebrachial angular limb deformity (ALD) dogs (10 uniapical and 10 biapical deformities). Limbs were evaluated using CT. Frontal, sagittal, and axial plane (torsion) values were obtained using published guidelines and compared between groups and limbs. Radial torsion reliability was assessed among 3 observers using intraclass correlation coefficients (ICC). The mean (±SD) radial torsion of normal dogs was 3.6° ± 6.4° and contained a significant right to left limb variation of 2.6°. Mean radial torsion in uniapical ALD limbs (3.6° ± 18.7°) was not significantly different from biapical ALD limbs (8.9° ± 17.9°). There was a wide range of torsion values in normal and ALD limbs. The interobserver reliability was excellent (ICC > 0.8) for normal dogs, good (0.73) for uniapical, and excellent (0.89) for biapical ALD limbs. The intraobserver reliability was excellent (>0.8) for all groups. There was a small side-to-side variation of radial torsion in normal dogs. With directed training, torsion assessment using CT is reliable in dogs with and without antebrachial bone deformity. © 2016 The American College of Veterinary Surgeons.

  18. Evaluation of novel computerized tomography scoring systems in human traumatic brain injury: An observational, multicenter study

    PubMed Central

    Kivisaari, Riku; Svensson, Mikael; Skrifvars, Markus B.

    2017-01-01

    Background Traumatic brain injury (TBI) is a major contributor to morbidity and mortality. Computerized tomography (CT) scanning of the brain is essential for diagnostic screening of intracranial injuries in need of neurosurgical intervention, but may also provide information concerning patient prognosis and enable baseline risk stratification in clinical trials. Novel CT scoring systems have been developed to improve current prognostic models, including the Stockholm and Helsinki CT scores, but so far have not been extensively validated. The primary aim of this study was to evaluate the Stockholm and Helsinki CT scores for predicting functional outcome, in comparison with the Rotterdam CT score and Marshall CT classification. The secondary aims were to assess which individual components of the CT scores best predict outcome and what additional prognostic value the CT scoring systems contribute to a clinical prognostic model. Methods and findings TBI patients requiring neuro-intensive care and not included in the initial creation of the Stockholm and Helsinki CT scoring systems were retrospectively included from prospectively collected data at the Karolinska University Hospital (n = 720 from 1 January 2005 to 31 December 2014) and Helsinki University Hospital (n = 395 from 1 January 2013 to 31 December 2014), totaling 1,115 patients. The Marshall CT classification and the Rotterdam, Stockholm, and Helsinki CT scores were assessed using the admission CT scans. Known outcome predictors at admission were acquired (age, pupil responsiveness, admission Glasgow Coma Scale, glucose level, and hemoglobin level) and used in univariate, and multivariable, regression models to predict long-term functional outcome (dichotomizations of the Glasgow Outcome Scale [GOS]). In total, 478 patients (43%) had an unfavorable outcome (GOS 1–3). In the combined cohort, overall prognostic performance was more accurate for the Stockholm CT score (Nagelkerke’s pseudo-R2 range 0.24–0.28) and the Helsinki CT score (0.18–0.22) than for the Rotterdam CT score (0.13–0.15) and Marshall CT classification (0.03–0.05). Moreover, the Stockholm and Helsinki CT scores added the most independent prognostic value in the presence of other known clinical outcome predictors in TBI (6% and 4%, respectively). The aggregate traumatic subarachnoid hemorrhage (tSAH) component of the Stockholm CT score was the strongest predictor of unfavorable outcome. The main limitations were the retrospective nature of the study, missing patient information, and the varying follow-up time between the centers. Conclusions The Stockholm and Helsinki CT scores provide more information on the damage sustained, and give a more accurate outcome prediction, than earlier classification systems. The strong independent predictive value of tSAH may reflect an underrated component of TBI pathophysiology. A change to these newer CT scoring systems may be warranted. PMID:28771476

  19. Dual-modality brain PET-CT image segmentation based on adaptive use of functional and anatomical information.

    PubMed

    Xia, Yong; Eberl, Stefan; Wen, Lingfeng; Fulham, Michael; Feng, David Dagan

    2012-01-01

    Dual medical imaging modalities, such as PET-CT, are now a routine component of clinical practice. Medical image segmentation methods, however, have generally only been applied to single modality images. In this paper, we propose the dual-modality image segmentation model to segment brain PET-CT images into gray matter, white matter and cerebrospinal fluid. This model converts PET-CT image segmentation into an optimization process controlled simultaneously by PET and CT voxel values and spatial constraints. It is innovative in the creation and application of the modality discriminatory power (MDP) coefficient as a weighting scheme to adaptively combine the functional (PET) and anatomical (CT) information on a voxel-by-voxel basis. Our approach relies upon allowing the modality with higher discriminatory power to play a more important role in the segmentation process. We compared the proposed approach to three other image segmentation strategies, including PET-only based segmentation, combination of the results of independent PET image segmentation and CT image segmentation, and simultaneous segmentation of joint PET and CT images without an adaptive weighting scheme. Our results in 21 clinical studies showed that our approach provides the most accurate and reliable segmentation for brain PET-CT images. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. A framelet-based iterative maximum-likelihood reconstruction algorithm for spectral CT

    NASA Astrophysics Data System (ADS)

    Wang, Yingmei; Wang, Ge; Mao, Shuwei; Cong, Wenxiang; Ji, Zhilong; Cai, Jian-Feng; Ye, Yangbo

    2016-11-01

    Standard computed tomography (CT) cannot reproduce spectral information of an object. Hardware solutions include dual-energy CT which scans the object twice in different x-ray energy levels, and energy-discriminative detectors which can separate lower and higher energy levels from a single x-ray scan. In this paper, we propose a software solution and give an iterative algorithm that reconstructs an image with spectral information from just one scan with a standard energy-integrating detector. The spectral information obtained can be used to produce color CT images, spectral curves of the attenuation coefficient μ (r,E) at points inside the object, and photoelectric images, which are all valuable imaging tools in cancerous diagnosis. Our software solution requires no change on hardware of a CT machine. With the Shepp-Logan phantom, we have found that although the photoelectric and Compton components were not perfectly reconstructed, their composite effect was very accurately reconstructed as compared to the ground truth and the dual-energy CT counterpart. This means that our proposed method has an intrinsic benefit in beam hardening correction and metal artifact reduction. The algorithm is based on a nonlinear polychromatic acquisition model for x-ray CT. The key technique is a sparse representation of iterations in a framelet system. Convergence of the algorithm is studied. This is believed to be the first application of framelet imaging tools to a nonlinear inverse problem.

  1. Role of fluorine-18 fluoride PET-CT scan in the assessment of unilateral condylar hyperplasia in faciomandibular asymmetry patients: a preliminary study.

    PubMed

    Ahmed, Rais; Singh, Satinder P; Mittal, Bhagwant R; Rattan, Vidya; Parghane, Rahul; Utreja, Ashok

    2016-03-01

    This prospective study was aimed to determine and quantify the change in mandibular condylar hyperactivity over a period of time by using a fluorine-18 (18F) fluoride PET-computed tomography (CT) scan. Sixteen patients (age 19.50 ± 2.58 years) with noticeable faciomandibular asymmetry caused by unilateral condylar hyperplasia (UCH) were included in the test group and underwent an 18F-fluoride PET-CT scan at the beginning of the study (T0); these patients were then followed up for a minimum of 12 months, after which the 18F-fluoride PET-CT scan was repeated at first follow-up (T1). An age-matched control group consisted of 10 patients with apparently symmetrical faces whose PET-CT scans were acquired for some other medical conditions. Statistical analysis of maximum standardized uptake values (SUV max) obtained through 18F-fluoride PET-CT was performed using the paired t-test. Mean SUV max of the affected condyle at T0 and T1 was 9.18 ± 4.07 and 9.18 ± 3.88, respectively. The mean SUV max of the contralateral condyle at T0 and T1 was 6.21 ± 2.30 and 6.66 ± 2.64, respectively. The mean right-left difference in tracer uptake between the test and control groups both at T0 and T1 was statistically significant. Right-left percentage difference of isotope uptake of the test group was 16.87 ± 15.75% at T0 and 14.97 ± 12.72% at T1. Right-left percentage difference of isotope uptake of the control group was 5.51 ± 5.72%. Although these differences were statistically significant, their clinical relevance was insignificant. SUV max of the higher uptake side and the lower uptake side of the control group was 5.63 ± 1.85 and 5.09 ± 1.83, respectively. Great diversity exists in the clinical presentation of UCH. The growth trend of UCH is highly variable because of the age and sex of patients. The results of the present study show that the 18F-fluoride PET-CT scan may guide us in determining the right time and in making the right choice of surgico-orthodontic intervention in UCH patients. The clinical presentation and SUV max of PET-CT of UCH patients were in agreement with each other. The baseline values of the control group indicated that these could also be used to differentiate normal from abnormal condylar growth in potential class III skeletal pattern cases - that is, patients having sagittal skeletal dysplasia resulting from either maxillary deficiency or mandibular protrusion, or both in combination, thus resulting in a concave facial profile.

  2. Correlation between CT-based measured renal volumes and nuclear-renography-based split renal function in living kidney donors. Clinical diagnostic utility and practice patterns.

    PubMed

    Diez, Alejandro; Powelson, John; Sundaram, Chandru P; Taber, Tim E; Mujtaba, Muhammad A; Yaqub, Muhammad S; Mishler, Dennis P; Goggins, William C; Sharfuddin, Asif A

    2014-06-01

    Living donor evaluation involves imaging to determine the choice of kidney for nephrectomy. Our aim was to study the diagnostic accuracy and correlation between CT-based volume measurements and split renal function (SRF) as measured by nuclear renography in potential living donors and its impact on kidney selection decision. We analyzed 190 CT-based volume measurements in healthy donors, of which 65 donors had a radionuclide study performed to determine SRF. There were no differences in demographics, anthropometric measurements, total volumes, eGFR, creatinine clearances between those who required a nuclear scan and those who did not. There was a significant correlation between CT-volume-measurement-based SRF and nuclear-scan-based SRF (Pearson coefficient r 0.59; p < 0.001). Furthermore, selective nuclear-based SRF allowed careful selection of donor nephrectomy, leaving the donor with the higher functioning kidney in most cases. There was also a significantly higher number of right-sided nephrectomies selected after nuclear-based SRF studies. CT-based volume measurements in living donor imaging have sufficient correlation with nuclear-based SRF. Selective use of nuclear-scan-based SRF allows careful selection for donor nephrectomy. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. New trends in the cyber and street market of recreational drugs? The case of 2C-T-7 ('Blue Mystic').

    PubMed

    Schifano, Fabrizio; Deluca, Paolo; Agosti, Lisa; Martinotti, Giovanni; Corkery, John M; Alex, Baldacchino; Caterina, Bonan; Heikki, Bothas; Raffaella, Brigada; Anna, Comacchio; Lucia, Di Furia; Dorte, Duarte Rui Eastwood; Magi, Farré; Susana, Ferreira; Irene, Flores; Claude, Guionnet; Lisbet, Harder; Lene, Stokholm Jensen; Mauro, Leoni; Christopher, Littlejohn; Aino, Majava; Teuvo, Peltoniemi; Milena, Pizza; Salman, Rawaf; Damien, Robert; Angela, Rossi Maria; Francesco, Rovetto; Norbert, Scherbaum; Holger, Siemann; Josep, Tarrago; Marta, Torrens; Francesco, Zambello

    2005-11-01

    2C-T-7 ('Blue Mystic'), an illicit compound which shows similarities with MDMA and other designer drugs, has been only occasionally identified in the EU, but discussion on the Internet between experimenters has recently grown significantly. We aimed at collecting together in a review the available information on 2C-T-7, both at the cyber and at the street market level. 2C-T-7 was first synthesized in 1986; its desired effects include both a sense of empathy and of well-being. Hallucinations, nausea, anxiety, panic attacks and paranoid ideation are anecdotally reported. According to the different European sources here approached, the availability of 2C-T-7 at street level seems to be currently very low, although one death related to a mono-intoxication with 2C-T-7 has been documented in the USA. With respect to information on 2C-T-7 available online, due to both redundancy and relevance issues the initial identified sample of 360 was reduced to 118 websites. In 14 (11.9%) websites, the detailed description of the 2C-T-7 synthesis was given. Harm Reduction websites appeared significantly earlier in the search engines results' list than Anti drugs (p 0.006) websites. Five (4.2%) websites apparently offered 2C-T-7 for sale. The large body of knowledge available online seems to contrast with small numbers of seizures at street level; an exhaustive web mapping of drug-related issues may be of interest for the clinician. Projects aimed at designing more 'attractive' prevention websites should be planned and future studies should better assess the characteristics of those consumers who take advantage of the online information of hallucinogenic compounds.

  4. A Comparison between 18F-FDG PET/CT Imaging and Biological and Radiological Findings in Restaging of Hepatoblastoma Patients

    PubMed Central

    Treglia, Giorgio; Pagano, Manuela; Fania, Piercarlo; Basso, Maria Eleonora; Fagioli, Franca; Ficola, Umberto

    2013-01-01

    Background. In this study we retrospectively evaluated if 18F-FDG-PET/CT provided incremental diagnostic information over CI in a group of hepatoblastoma patients performing restaging. Procedure. Nine patients (mean age: 5.9 years; range: 3.1–12 years) surgically treated for hepatoblastoma were followed up by clinical examination, serum α-FP monitoring, and US. CI (CT or MRI) and PET/CT were performed in case of suspicion of relapse. Fine-needle aspiration biopsies (FNAB) were carried out for final confirmation if the results of CI, PET/CT, and/or α-FP levels were suggestive of relapse. PET/CT and CI findings were analyzed for comparison purposes, using FNAB as reference standard. Results. α-FP level was suggestive of disease recurrence in 8/9 patients. Biopsy was performed in 8/9 cases. CI and PET/CT resulted to be concordant in 5/9 patients (CI identified recurrence of disease, but 18F-FDG-PET/CT provided a better definition of disease extent); in 4/9 cases, CI diagnostic information resulted in negative findings, whereas PET/CT correctly detected recurrence of disease. 18F-FDG-PET/CT showed an agreement of 100% (8/8) with FNAB results. Conclusions. 18F-FDG-PET/CT scan seems to better assess HB patients with respect to CI and may provide incremental diagnostic value in the restaging of this group of patients. PMID:24063012

  5. CT protocols in interstitial lung diseases--a survey among members of the European Society of Thoracic Imaging and a review of the literature.

    PubMed

    Prosch, Helmut; Schaefer-Prokop, Cornelia M; Eisenhuber, Edith; Kienzl, Daniela; Herold, Christian J

    2013-06-01

    The aim of this study was to survey the current CT protocols used by members of the European Society of Thoracic Imaging (ESTI) to evaluate patients with interstitial lung diseases (ILD). A questionnaire was e-mailed to 173 ESTI members. The survey focussed on CT acquisition and reconstruction techniques. In particular, questions referred to the use of discontinuous HRCT or volume CT protocols, the acquisition of additional acquisitions in expiration or in the prone position, and methods of radiation dose reduction and on reconstruction algorithms. The overall response rate was 37 %. Eighty-five percent of the respondents used either volume CT alone or in combination with discontinuous HRCT. Forty-five percent of the respondents adapt their CT protocols to the patient's weight and/or age. Expiratory CT or CT in the prone position was performed by 58 % and 59 % of the respondents, respectively. The number of reconstructed series ranged from two to eight. Our survey showed that radiologists with a special interest and experience in chest radiology use a variety of CT protocols for the evaluation of ILD. There is a clear preference for volumetric scans and a strong tendency to use the 3D information. • Experienced thoracic radiologists use various CT protocols for evaluating interstitial lung diseases. • Most workers prefer volumetric CT acquisitions, making use of the 3D information • More attention to reducing the radiation dose appears to be needed.

  6. Comparison of Scientific Calipers and Computer-Enabled CT Review for the Measurement of Skull Base and Craniomaxillofacial Dimensions

    PubMed Central

    Citardi, Martin J.; Herrmann, Brian; Hollenbeak, Chris S.; Stack, Brendan C.; Cooper, Margaret; Bucholz, Richard D.

    2001-01-01

    Traditionally, cadaveric studies and plain-film cephalometrics provided information about craniomaxillofacial proportions and measurements; however, advances in computer technology now permit software-based review of computed tomography (CT)-based models. Distances between standardized anatomic points were measured on five dried human skulls with standard scientific calipers (Geneva Gauge, Albany, NY) and through computer workstation (StealthStation 2.6.4, Medtronic Surgical Navigation Technology, Louisville, CO) review of corresponding CT scans. Differences in measurements between the caliper and CT model were not statistically significant for each parameter. Measurements obtained by computer workstation CT review of the cranial skull base are an accurate representation of actual bony anatomy. Such information has important implications for surgical planning and clinical research. ImagesFigure 1Figure 2Figure 3 PMID:17167599

  7. Development of lung cancer CT screening operating support system

    NASA Astrophysics Data System (ADS)

    Ishigaki, Rikuta; Hanai, Kozou; Suzuki, Masahiro; Kawata, Yoshiki; Niki, Noboru; Eguchi, Kenji; Kakinuma, Ryutaro; Moriyama, Noriyuki

    2009-02-01

    In Japan, lung cancer death ranks first among men and third among women. Lung cancer death is increasing yearly, thus early detection and treatment are needed. For this reason, CT screening for lung cancer has been introduced. The CT screening services are roughly divided into three sections: office, radiology and diagnosis sections. These operations have been performed through paper-based or a combination of paper-based and an existing electronic health recording system. This paper describes an operating support system for lung cancer CT screening in order to make the screening services efficient. This operating support system is developed on the basis of 1) analysis of operating processes, 2) digitalization of operating information, and 3) visualization of operating information. The utilization of the system is evaluated through an actual application and users' survey questionnaire obtained from CT screening centers.

  8. Secure fixation of femoral bone plug with a suspensory button in anatomical anterior cruciate ligament reconstruction with bone-patellar tendon-bone graft

    PubMed Central

    TAKETOMI, SHUJI; INUI, HIROSHI; NAKAMURA, KENSUKE; YAMAGAMI, RYOTA; TAHARA, KEITARO; SANADA, TAKAKI; MASUDA, HIRONARI; TANAKA, SAKAE; NAKAGAWA, TAKUMI

    2015-01-01

    Purpose the efficacy and safety of using a suspensory button for femoral fixation in anatomical anterior cruciate ligament (ACL) reconstruction with bone-patellar tendon-bone (BPTB) graft have not been established. The purpose of the current study was to evaluate bone plug integration onto the femoral socket and migration of the bone plug and the EndoButton (EB) (Smith & Nephew, Andover, MA, USA) after rectangular tunnel ACL reconstruction with BPTB autograft. Methods thirty-four patients who underwent anatomical rectangular ACL reconstruction with BPTB graft using EB for femoral fixation and in whom three-dimensional (3D) computed tomography (CT) was performed one week and one year after surgery were included in this study. Bone plug integration onto the femoral socket, bone plug migration, soft tissue interposition, EB migration and EB rotation were evaluated on 3D CT. The clinical outcome was also assessed and correlated with the imaging outcomes. Results the bone plug was integrated onto the femoral socket in all cases. The incidence of bone plug migration, soft tissue interposition, EB migration and EB rotation was 15, 15, 9 and 56%, respectively. No significant association was observed between the imaging outcomes. The postoperative mean Lysholm score was 97.1 ± 5.0 points. The postoperative side-to-side difference, evaluated using a KT-2000 arthrometer, averaged 0.5 ± 1.3 mm. There were no complications associated with EB use. Imaging outcomes did not affect the postoperative KT side-to-side difference. Conclusions the EB is considered a reliable device for femoral fixation in anatomical rectangular tunnel ACL reconstruction with BPTB autograft. Level of evidence Level IV, therapeutic case series. PMID:26889465

  9. Prediction of Hip Failure Load: In Vitro Study of 80 Femurs Using Three Imaging Methods and Finite Element Models-The European Fracture Study (EFFECT).

    PubMed

    Pottecher, Pierre; Engelke, Klaus; Duchemin, Laure; Museyko, Oleg; Moser, Thomas; Mitton, David; Vicaut, Eric; Adams, Judith; Skalli, Wafa; Laredo, Jean Denis; Bousson, Valérie

    2016-09-01

    Purpose To evaluate the performance of three imaging methods (radiography, dual-energy x-ray absorptiometry [DXA], and quantitative computed tomography [CT]) and that of a numerical analysis with finite element modeling (FEM) in the prediction of failure load of the proximal femur and to identify the best densitometric or geometric predictors of hip failure load. Materials and Methods Institutional review board approval was obtained. A total of 40 pairs of excised cadaver femurs (mean patient age at time of death, 82 years ± 12 [standard deviation]) were examined with (a) radiography to measure geometric parameters (lengths, angles, and cortical thicknesses), (b) DXA (reference standard) to determine areal bone mineral densities (BMDs), and (c) quantitative CT with dedicated three-dimensional analysis software to determine volumetric BMDs and geometric parameters (neck axis length, cortical thicknesses, volumes, and moments of inertia), and (d) quantitative CT-based FEM to calculate a numerical value of failure load. The 80 femurs were fractured via mechanical testing, with random assignment of one femur from each pair to the single-limb stance configuration (hereafter, stance configuration) and assignment of the paired femur to the sideways fall configuration (hereafter, side configuration). Descriptive statistics, univariate correlations, and stepwise regression models were obtained for each imaging method and for FEM to enable us to predict failure load in both configurations. Results Statistics reported are for stance and side configurations, respectively. For radiography, the strongest correlation with mechanical failure load was obtained by using a geometric parameter combined with a cortical thickness (r(2) = 0.66, P < .001; r(2) = 0.65, P < .001). For DXA, the strongest correlation with mechanical failure load was obtained by using total BMD (r(2) = 0.73, P < .001) and trochanteric BMD (r(2) = 0.80, P < .001). For quantitative CT, in both configurations, the best model combined volumetric BMD and a moment of inertia (r(2) = 0.78, P < .001; r(2) = 0.85, P < .001). FEM explained 87% (P < .001) and 83% (P < .001) of bone strength, respectively. By combining (a) radiography and DXA and (b) quantitative CT and DXA, correlations with mechanical failure load increased to 0.82 (P < .001) and 0.84 (P < .001), respectively, for radiography and DXA and to 0.80 (P < .001) and 0.86 (P < .001) , respectively, for quantitative CT and DXA. Conclusion Quantitative CT-based FEM was the best method with which to predict the experimental failure load; however, combining quantitative CT and DXA yielded a performance as good as that attained with FEM. The quantitative CT DXA combination may be easier to use in fracture prediction, provided standardized software is developed. These findings also highlight the major influence on femoral failure load, particularly in the trochanteric region, of a densitometric parameter combined with a geometric parameter. (©) RSNA, 2016 Online supplemental material is available for this article.

  10. High-intensity focused ultrasound (HIFU) in patients with solid malignancies: evaluation of feasibility, local tumour response and clinical results.

    PubMed

    Orgera, G; Monfardini, L; Della Vigna, P; Zhang, L; Bonomo, G; Arnone, P; Padrenostro, M; Orsi, F

    2011-08-01

    The purpose of this study was to evaluate the safety and efficacy of ultrasound-guided high-intensity focused ultrasound (USgHIFU) for ablation of solid tumours without damaging the surrounding structures. A specific written informed consent was obtained from every patient before treatment. From September 2008 to April 2009, 22 patients with 29 lesions were treated: nine patients with liver and/or soft-tissue metastases from colorectal carcinoma (CRC), six with pancreatic solid lesions, three with liver and/or bone metastases from breast cancer, one with osteosarcoma, one with muscle metastasis from lung cancer, one with iliac metastasis from multiple myeloma and one with abdominal liposarcoma. The mean diameter of tumours was 4.2 cm. All patients were evaluated 1 day, 1 month and 3 months after HIFU treatment by multidetector computed tomography (MDCT), positron-emission tomography (PET)-CT and clinical evaluation. The treatment time and adverse events were recorded. All patients had one treatment. Average treatment and sonication times were, respectively, 162.7 and 37.4 min. PET-CT or/and MDCT showed complete response in 11/13 liver metastases; all bone, soft-tissue and pancreatic lesions were palliated in symptoms, with complete response to PET-CT, MDCT or magnetic resonance imaging (MRI); the liposarcoma was almost completely ablated at MRI. Local oedema was observed in three patients. No other side effects were observed. All patients were discharged 1-3 days after treatment. According to our preliminary experience in a small number of patients, we conclude that HIFU ablation is a safe and feasible technique for locoregional treatment and is effective in pain control.

  11. Maximizing Information From Routine Staging Computed Tomography in Functional Neuroendocrine Neoplasms: Are There Findings Indicating the Presence of Carcinoid Heart Disease?

    PubMed

    Baur, Alexander Daniel Jacques; Kunz, Florian; Schwenke, Carsten; Pschowski, René; Röpke, Torsten Kai; Pavel, Marianne; Denecke, Timm

    2016-01-01

    The aim of this study was to evaluate signs of right-sided heart dysfunction on staging computed tomography (CT) as indirect indicators of carcinoid heart disease. Patients with functionally active neuroendocrine neoplasm and different grades of tricuspid valve regurgitation (TR) were identified. Two readers independently reviewed contrast-enhanced staging CT performed within 90 days before or after echocardiography. Logistic regression and receiver operating analyses were used to asses the predictive value of right ventricle-left ventricle ratio (RV-LV ratio), ventricular septal bowing, retrograde contrast filling of the hepatic veins during contrast injection, and time to aortal enhancement greater than 100 Hounsfield units during bolus tracking for TR. Forty-four examinations were evaluated (11 with TR = 0, 16 with TR = 1, 9 with TR = 2, and 8 with TR = 3). Right ventricle-LV ratio was found to predict TR less than or equal to 1 versus TR greater than 1 (P = 0.0188) and TR less than or equal to 1 versus TR equals 2 (P = 0.0082). A prolonged time to aortal enhancement greater than 100 Hounsfield units during bolus tracking predicted TR less than or equal to 1 versus TR greater than 1 (P = 0.0077). Area under the curve for RV-LV ratio was 0.86 when differentiating TR less than or equal to 1 versus TR equals 2. With a cutoff of 1.07, sensitivity was 0.89, and specificity was 0.72. In patients with functionally active neuroendocrine neoplasm, an RV-LV ratio of more than 1.07 predicted TR with a relatively high sensitivity and moderate specificity and thus could serve as an indicator of subclinical carcinoid heart disease on routine staging CT.

  12. The significance of 99mTc-MAA SPECT/CT liver perfusion imaging in treatment planning for 90Y-microsphere selective internal radiation treatment.

    PubMed

    Ahmadzadehfar, Hojjat; Sabet, Amir; Biermann, Kim; Muckle, Marianne; Brockmann, Holger; Kuhl, Christiane; Wilhelm, Kai; Biersack, Hans-Jürgen; Ezziddin, Samer

    2010-08-01

    Selective internal radiation therapy (SIRT), a catheter-based liver-directed modality for treating primary and metastatic liver cancer, requires appropriate planning to maximize its therapeutic response and minimize its side effects. (99m)Tc-macroaggregated albumin (MAA) scanning should precede the therapy to detect any extrahepatic shunting to the lung or gastrointestinal tract. Our aim was to compare the ability of SPECT/CT with that of planar imaging and SPECT in the detection and localization of extrahepatic (99m)Tc-MAA accumulation and to evaluate the impact of SPECT/CT on SIRT treatment planning and its added value to angiography in this setting. Ninety diagnostic hepatic angiograms with (99m)Tc-MAA were obtained for 76 patients with different types of cancer. All images were reviewed retrospectively for extrahepatic MAA deposition in the following order: planar, non-attenuation-corrected SPECT, and SPECT/CT. Review of angiograms and follow-up of patients with abdominal shunting served as reference standards. Extrahepatic accumulation was detected by planar imaging, SPECT, and SPECT/CT in 12%, 17%, and 42% of examinations, respectively. The sensitivity for detecting extrahepatic shunting with planar imaging, SPECT, and SPECT/CT was 32%, 41%, and 100%, respectively; specificity was 98%, 98%, and 93%, respectively. The respective positive predictive values were 92%, 93%, and 89%, and the respective negative predictive values were 71%, 73%, and 100%. The therapy plan was changed according to the results of planar imaging, SPECT, and SPECT/CT in 7.8%, 8.9%, and 29% of patients, respectively. In pre-SIRT planning, (99m)Tc-MAA SPECT/CT is valuable for identifying extrahepatic visceral sites at risk for postradioembolization complications.

  13. C2 spondylotic radiculopathy: the nerve root impingement mechanism investigated by para-sagittal CT/MRI, dynamic rotational CT, intraoperative microscopic findings, and treated by microscopic posterior foraminotomy.

    PubMed

    Fujiwara, Yasushi; Izumi, Bunichiro; Fujiwara, Masami; Nakanishi, Kazuyoshi; Tanaka, Nobuhiro; Adachi, Nobuo; Manabe, Hideki

    2017-04-01

    C2 radiculopathy is known to cause occipito-cervical pain, but their pathology is unclear because of its rarity and unique anatomy. In this paper, we investigated the mechanism of C2 radiculopathy that underwent microscopic cervical foraminotomies (MCF). Three cases with C2 radiculopathy treated by MCF were investigated retrospectively. The mean follow-up period was 24 months. Pre-operative symptoms, imaging studies including para-sagittal CT and MRI, rotational dynamic CT, and intraoperative findings were investigated. There were 1 male and 2 females. The age of patients were ranged from 50 to 79 years. All cases had intractable occipito-cervical pain elicited by the cervical rotation. C2 nerve root block was temporally effective. There was unilateral spondylosis in symptomatic side without obvious atlatoaxial instability. Para-sagittal MRI and CT showed severe foraminal stenosis at C1-C2 due to the bony spur derived from the lateral atlanto-axial joints. In one case, dynamic rotational CT showed that the symptomatic foramen became narrower on rotational position. MCF was performed in all cases, and the C2 nerve root was impinged between the inferior edge of the C1 posterior arch and bony spur from the C1-C2 joint. After surgery, occipito-cervical pain disappeared. This study demonstrated that mechanical impingement of the C2 nerve root is one of the causes of occipito-cervical pain and it was successfully treated by microscopic resection of the inferior edge of the C1 posterior arch. Para-sagittal CT and MRI, rotational dynamic CT, and nerve root block were effective for diagnosis.

  14. Computed tomographic anatomy of the heads of blue-and-gold macaws (Ara ararauna), African grey parrots (Psittacus erithacus), and monk parakeets (Myiopsitta monachus).

    PubMed

    Veladiano, Irene A; Banzato, Tommaso; Bellini, Luca; Montani, Alessandro; Catania, Salvatore; Zotti, Alessandro

    2016-12-01

    OBJECTIVE To create an atlas of the normal CT anatomy of the head of blue-and-gold macaws (Ara ararauna), African grey parrots (Psittacus erithacus), and monk parakeets (Myiopsitta monachus). ANIMALS 3 blue-and-gold macaws, 5 African grey parrots, and 6 monk parakeets and cadavers of 4 adult blue-and-gold macaws, 4 adult African grey parrots, and 7 monk parakeets. PROCEDURES Contrast-enhanced CT imaging of the head of the live birds was performed with a 4-multidetector-row CT scanner. Cadaveric specimens were stored at -20°C until completely frozen, and each head was then sliced at 5-mm intervals to create reference cross sections. Frozen cross sections were cleaned with water and photographed on both sides. Anatomic structures within each head were identified with the aid of the available literature, labeled first on anatomic photographs, and then matched to and labeled on corresponding CT images. The best CT reconstruction filter, window width, and window level for obtaining diagnostic images of each structure were also identified. RESULTS Most of the clinically relevant structures of the head were identified in both the cross-sectional photographs and corresponding CT images. Optimal visibility of the bony structures was achieved via CT with a standard soft tissue filter and pulmonary window. The use of contrast medium allowed a thorough evaluation of the soft tissues. CONCLUSIONS AND CLINICAL RELEVANCE The labeled CT images and photographs of anatomic structures of the heads of common pet parrot species created in this study may be useful as an atlas to aid interpretation of images obtained with any imaging modality.

  15. Longitudinal in vivo microcomputed tomography of mouse lungs: No evidence for radiotoxicity

    PubMed Central

    Vande Velde, Greetje; De Langhe, Ellen; Poelmans, Jennifer; Bruyndonckx, Peter; d'Agostino, Emiliano; Verbeken, Erik; Bogaerts, Ria; Himmelreich, Uwe

    2015-01-01

    Before microcomputed tomography (micro-CT) can be exploited to its full potential for longitudinal monitoring of transgenic and experimental mouse models of lung diseases, radiotoxic side effects such as inflammation or fibrosis must be considered. We evaluated dose and potential radiotoxicity to the lungs for long-term respiratory-gated high-resolution micro-CT protocols. Free-breathing C57Bl/6 mice underwent four different retrospectively respiratory gated micro-CT imaging schedules of repeated scans during 5 or 12 wk, followed by ex vivo micro-CT and detailed histological and biochemical assessment of lung damage. Radiation exposure, dose, and absorbed dose were determined by ionization chamber, thermoluminescent dosimeter measurements and Monte Carlo calculations. Despite the relatively large radiation dose delivered per micro-CT acquisition, mice did not show any signs of radiation-induced lung damage or fibrosis when scanned weekly during 5 and up to 12 wk. Doubling the scanning frequency and once tripling the radiation dose as to mimic the instant repetition of a failed scan also stayed without detectable toxicity after 5 wk of scanning. Histological analyses confirmed the absence of radiotoxic damage to the lungs, thereby demonstrating that long-term monitoring of mouse lungs using high-resolution micro-CT is safe. This opens perspectives for longitudinal monitoring of (transgenic) mouse models of lung diseases and therapeutic response on an individual basis with high spatial and temporal resolution, without concerns for radiation toxicity that could potentially influence the readout of micro-CT-derived lung biomarkers. This work further supports the introduction of micro-CT for routine use in the preclinical pulmonary research field where postmortem histological approaches are still the gold standard. PMID:26024893

  16. SU-D-18A-06: Variation of Controlled Breath Hold From CT Simulation to Treatment and Its Dosimetric Impact for Left-Sided Breast Radiotherapy with a Real-Time Optical Tracking System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mittauer, K; Deraniyagala, R; Li, J

    2014-06-01

    Purpose: Different breath-hold (BH) maneuvers (abdominal breathing vs. chest breathing) during CT simulation and treatment can lead to chest wall positional variation. The purpose of this study is to quantify the variation of active breathing control (ABC)-assisted BH and estimate its dosimetric impact for left-sided whole-breast radiotherapy with a real-time optical tracking system (OTS). Methods: Seven breast cancer patients were included. An in-house OTS tracked an infrared (IR) marker affixed over the xiphoid process of the patient at CT simulation and throughout the treatment course to measure BH variations. Correlation between the IR marker and the breast was studied formore » dosimetric purposes. The positional variations of 860 BHs were retrospectively incorporated into treatment plans to assess their dosimetric impact on breast and cardiac organs (heart and left anterior descending artery [LAD]). Results: The mean intrafraction variations were 2.8 mm, 2.7 mm, and 1.6 mm in the anteroposterior (AP), craniocaudal (CC), and mediolateral (ML) directions, respectively. Mean stability in any direction was within 1.5 mm. A general trend of BH undershoot at treatment relative to CT simulation was observed with an average of 4.4 mm, 3.6 mm, and 0.1 mm in the AP, CC, and ML directions, respectively. Undershoot up to 12.6 mm was observed for individual patients. The difference between the planned and delivered dose to breast targets was negligible. The average planned/delivered mean heart doses, mean LAD doses, and max LAD doses were 1.4/2.1, 7.4/15.7, and 18.6/31.0 Gy, respectively. Conclusion: Systematic undershoot was observed in ABC-assisted BHs from CT simulation to treatment. Its dosimetric impact on breast coverage was minimized with image guidance, but the benefits of cardiac organ sparing were degraded. A real-time tracking system can be used in junction with the ABC device to improve BH reproducibility.« less

  17. Septic Arthritis of the Temporomandibular Joint--Unusual Presentations.

    PubMed

    Lohiya, Sapna; Dillon, Jasjit

    2016-01-01

    This report describes 2 patients whose septic arthritis of the temporomandibular joint (SATMJ) presented atypically, resulting in treatment delay and complications. A 49-year-old man developed left-side facial allodynia, which was first treated unsuccessfully as trigeminal neuralgia. On day 21, the patient sustained facial trauma from a fall and presented to the emergency department (ED). Maxillofacial contrast-enhanced computed tomographic (CT) scan was suggestive of parotiditis, SATMJ, or hemarthrosis. His condition did not improve with empiric antibiotic treatment. On day 30, contrast-enhanced magnetic resonance imaging (MRI) confirmed SATMJ. Incision and drainage yielded 6 mL of pus and produced clinical improvement. Cultures grew methicillin-resistant Staphylococcus aureus, which was treated with amoxicillin plus clavulanate and sulfamethoxazole plus trimethoprim for 30 days. On day 59, the patient still had slight preauricular pain and CT-proved TMJ osteoarthritic changes. A 56-year-old woman developed right-side facial pain after a crown procedure on her right mandibular second molar. Oral prednisone (and clindamycin) produced partial relief. Her primary physician suspected temporal arteritis, but its biopsy result on day 11 was normal. Gradually, the patient developed trismus and malocclusion refractory to various medicines. On day 49, she presented to the ED. A contrast-enhanced maxillofacial CT scan suggested SATMJ. Incision and drainage yielded 30 mL of pus and produced clinical improvement. During days 50 to 57, the patient received intravenous ampicillin plus sulbactam and metronidazole. However, preauricular tenderness and drainage from the surgical incision persisted. On day 55, CT scan showed a residual abscess. Secondary debridement yielded 5 mL of pus. Culture grew coagulase-negative S aureus. On day 141, the patient still had slight preauricular pain and TMJ osteoarthritic changes on MRI. In these cases, the SATMJ diagnosis was delayed owing to the mildness of local and systemic manifestations, the possibility of confounding conditions, and the rarity of SATMJ. Contrast-enhanced CT and MRI facilitated the diagnosis. Abscess drainage alleviated the symptoms. Postinfectious osteoarthritis developed possibly from treatment delay. SATMJ should be considered in all patients with enigmatic preauricular pain, trismus, or malocclusion. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Automated extraction of radiation dose information for CT examinations.

    PubMed

    Cook, Tessa S; Zimmerman, Stefan; Maidment, Andrew D A; Kim, Woojin; Boonn, William W

    2010-11-01

    Exposure to radiation as a result of medical imaging is currently in the spotlight, receiving attention from Congress as well as the lay press. Although scanner manufacturers are moving toward including effective dose information in the Digital Imaging and Communications in Medicine headers of imaging studies, there is a vast repository of retrospective CT data at every imaging center that stores dose information in an image-based dose sheet. As such, it is difficult for imaging centers to participate in the ACR's Dose Index Registry. The authors have designed an automated extraction system to query their PACS archive and parse CT examinations to extract the dose information stored in each dose sheet. First, an open-source optical character recognition program processes each dose sheet and converts the information to American Standard Code for Information Interchange (ASCII) text. Each text file is parsed, and radiation dose information is extracted and stored in a database which can be queried using an existing pathology and radiology enterprise search tool. Using this automated extraction pipeline, it is possible to perform dose analysis on the >800,000 CT examinations in the PACS archive and generate dose reports for all of these patients. It is also possible to more effectively educate technologists, radiologists, and referring physicians about exposure to radiation from CT by generating report cards for interpreted and performed studies. The automated extraction pipeline enables compliance with the ACR's reporting guidelines and greater awareness of radiation dose to patients, thus resulting in improved patient care and management. Copyright © 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. In vivo tomographic imaging of lung colonization of tumour in mouse with simultaneous fluorescence and X-ray CT.

    PubMed

    Zhang, Bin; Gao, Fuping; Wang, Mengjiao; Cao, Xu; Liu, Fei; Wang, Xin; Luo, Jianwen; Wang, Guangzhi; Bai, Jing

    2014-01-01

    Non-invasive in vivo imaging of diffuse and wide-spread colonization within the lungs, rather than distinct solid primary tumors, is still a challenging work. In this work, a lung colonization mouse model bearing A549 human lung tumor was simultaneously scanned by a dual-modality fluorescence molecular tomography (FMT) and X-ray computed tomography (CT) system in vivo. A two steps method which incorporates CT structural information into the FMT reconstruction procedure is employed to provide concurrent anatomical and functional information. By using the target-specific fluorescence agent, the fluorescence tomographic results show elevated fluorescence intensity deep within the lungs which is colonized with diffuse and wide-spread tumors. The results were confirmed with ex vivo fluorescence reflectance imaging and histological examination of the lung tissues. With FMT reconstruction combined with the CT information, the dual-modality FMT/micro-CT system is expected to offer sensitive and noninvasive imaging of diffuse tumor colonization within the lungs in vivo. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. 3. VIEW FROM THE NORTH OF THE WEST END OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. VIEW FROM THE NORTH OF THE WEST END OF THE NORTH SIDE. EXPOSED STEEL STRUCTURE ON ROOF WAS ADDED IN 1933-1934 TO HOUSE PULVERIZED COAL BOILERS 902 AND 903. SHEATHING PANELS HAVE BEEN REMOVED TO PRECLUDE ADDITIONAL DAMAGE. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  1. 13. View north within enclosure between old and new sections ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. View north within enclosure between old and new sections of Armory Street Pump House. Object at is a muffler and exhaust stack for the turbine powered stand-by generator unit. - Lake Whitney Water Filtration Plant, Armory Street Pumphouse, North side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  2. Radiation Dose in the Thyroid and the Thyroid Cancer Risk Attributable to CT Scans for Pediatric Patients in One General Hospital of China

    PubMed Central

    Su, Yin-Ping; Niu, Hao-Wei; Chen, Jun-Bo; Fu, Ying-Hua; Xiao, Guo-Bing; Sun, Quan-Fu

    2014-01-01

    Objective: To quantify the radiation dose in the thyroid attributable to different CT scans and to estimate the thyroid cancer risk in pediatric patients. Methods: The information about pediatric patients who underwent CT scans was abstracted from the radiology information system in one general hospital between 1 January 2012 and 31 December 2012. The radiation doses were calculated using the ImPACT Patient Dosimetry Calculator and the lifetime attributable risk (LAR) of thyroid cancer incidence was estimated based on the National Academies Biologic Effects of Ionizing Radiation VII model. Results: The subjects comprised 922 children, 68% were males, and received 971 CT scans. The range of typical radiation dose to the thyroid was estimated to be 0.61–0.92 mGy for paranasal sinus CT scans, 1.10–2.45 mGy for head CT scans, and 2.63–5.76 mGy for chest CT scans. The LAR of thyroid cancer were as follows: for head CT, 1.1 per 100,000 for boys and 8.7 per 100,000 for girls; for paranasal sinus CT scans, 0.4 per 100,000 for boys and 2.7 per 100,000 for girls; for chest CT scans, 2.1 per 100,000 for boys and 14.1 per 100,000 for girls. The risk of thyroid cancer was substantially higher for girls than for the boys, and from chest CT scans was higher than that from head or paransal sinus CT scans. Conclusions: Chest CT scans caused higher thyroid dose and the LAR of thyroid cancer incidence, compared with paransal sinus or head CT scans. Therefore, physicians should pay more attention to protect the thyroid when children underwent CT scans, especially chest CT scans. PMID:24608902

  3. Systematic Review and Meta-Analysis of CT Features for Differentiating Complicated and Uncomplicated Appendicitis.

    PubMed

    Kim, Hae Young; Park, Ji Hoon; Lee, Yoon Jin; Lee, Sung Soo; Jeon, Jong-June; Lee, Kyoung Ho

    2018-04-01

    Purpose To perform a systematic review and meta-analysis to identify computed tomographic (CT) features for differentiating complicated appendicitis in patients suspected of having appendicitis and to summarize their diagnostic accuracy. Materials and Methods Studies on diagnostic accuracy of CT features for differentiating complicated appendicitis (perforated or gangrenous appendicitis) in patients suspected of having appendicitis were searched in Ovid-MEDLINE, EMBASE, and the Cochrane Library. Overlapping descriptors used in different studies to denote the same image finding were subsumed under a single CT feature. Pooled diagnostic accuracy of the CT features was calculated by using a bivariate random effects model. CT features with pooled diagnostic odds ratios with 95% confidence intervals not including 1 were considered as informative. Results Twenty-three studies were included, and 184 overlapping descriptors for various CT findings were subsumed under 14 features. Of these, 10 features were informative for complicated appendicitis. There was a general tendency for these features to show relatively high specificity but low sensitivity. Extraluminal appendicolith, abscess, appendiceal wall enhancement defect, extraluminal air, ileus, periappendiceal fluid collection, ascites, intraluminal air, and intraluminal appendicolith showed pooled specificity greater than 70% (range, 74%-100%), but sensitivity was limited (range, 14%-59%). Periappendiceal fat stranding was the only feature that showed high sensitivity (94%; 95% confidence interval: 86%, 98%) but low specificity (40%; 95% confidence interval, 23%, 60%). Conclusion Ten informative CT features for differentiating complicated appendicitis were identified in this study, nine of which showed high specificity, but low sensitivity. © RSNA, 2017 Online supplemental material is available for this article.

  4. Mott criticality and multiferroicity in organic κ-(BEDT-TTF)2X salts

    NASA Astrophysics Data System (ADS)

    Lang, Michael

    2014-03-01

    Layered organic charge-transfer (CT) salts of the κ-(BEDT-TTF)2X family show a wealth of electronic phases resulting from the interplay of strong electron-electron correlations, reduced dimensions and magnetic frustration. Of particular interest has been the bandwidth-controlled Mott transition, separating an antiferromagnetic (afm) insulating state from a correlated metallic and superconducting state. Whereas the hydrogenated X = Cu[N(CN)2]Br salt is located on the metallic side, the deuterated variant, denoted κ-D8, is situated in splitting distance to the Mott transition, enabling the s-shaped transition line TMI to be crossed via temperature sweeps. The talk will address the following aspects: 1) Thermal expansion measurements on single crystalline κ-D8 reveal discontinuous changes of the lattice parameters on crossing the Mott transition line and a huge anomaly close to the second-order critical end point of TMI. By elaborating on a scaling theory, we found that (i) the latter effect is a consequence of an almost divergence of the Grüneisen parameter Γ at the finite- T critical end point, and (ii) that the expansivity data of are in excellent agreement with the Mott criticality lying within the 2D Ising universality class, at variance with results from conductivity measurements. Thermal expansion measurements under Helium-gas pressure are underway for providing thermodynamic information at variable pressure. 2) Surprisingly, for the isostructural X = Cu[N(CN)2]Cl salt, located close to the Mott transition on the insulating side, we found that besides the well-established afm order at TN ~ 27 K, the system also reveals a ferroelectric transition at TFE, making this material the first multiferroic CT salt. Most remarkably, the measurements reveal TFE ~TN , suggesting a close interrelation between both types of ferroic order. Work was supported by Deutsche Forschungsgemeinschaft through the Collaborative Research Centers TRR 49 and TRR 80.

  5. Torsional Growth Modulation of Long Bones by Oblique Plating in a Rabbit Model.

    PubMed

    Lazarus, David E; Farnsworth, Christine L; Jeffords, Megan E; Marino, Nikolas; Hallare, Jericho; Edmonds, Eric W

    2018-02-01

    There is evidence that oblique tension band plating can affect torsional growth in long bones. This study sought to determine if the torsional growth could be modulated based on the angles of the tension band plating and whether or not oblique plating affected overall longitudinal growth. New Zealand White rabbits (10.5 wk old) had one screw placed on the metaphyseal side and one on the epiphyseal side of both medial and lateral sides of the right knee distal femoral physis. The sham group (n=5) included screw placement only. For the plate group (n=13), unlocked plates, angled from 0 to 76 degrees, connected the screws and spanned the physis. Radiographs were taken at biweekly intervals. After 6 weeks of growth, hindlimbs were harvested and microCT scans performed. Femoral length, distances between screw heads and angle between the plates were measured on radiographs. Femoral length differences were compared between groups. Femoral version was measured from 3D microCT. Plate angle changes were correlated to the difference in femoral version between limbs using Pearson correlation (significance was set to P<0.05 for all comparisons). Femur length difference between the contralateral and the operative side was significantly greater in the plate group compared with the sham group over time (P=0.049). Medial and lateral screw distances changed significantly more in the sham group than the plate group on both sides (P<0.001). A greater initial angle between plates resulted in a greater change in the angle between plates (P<0.001). Significant correlations were found between right-left side femoral version differences and initial plate angle (P=0.003) and plate angle change (P=0.014). The torsional effect of oblique plating seems to correlate with the amount of initial plate angle, with an additional, not negligible, longitudinal growth effect. Placing plates at given angles across open physes may result in predictable changes in bone torsion allowing for a safer and less invasive option when treating childhood torsional deformities, but the resulting shortening of the ipsilateral femur must be considered.

  6. Dual energy micro CT SkyScan 1173 for the characterization of urinary stone

    NASA Astrophysics Data System (ADS)

    Fitri, L. A.; Asyana, V.; Ridwan, T.; Anwary, F.; Soekersi, H.; Latief, F. D. E.; Haryanto, F.

    2016-03-01

    Knowledge of the composition of urinary stones is an essential part to determine suitable treatments for patients. The aim of this research is to characterize the urinary stones by using dual energy micro CT SkyScan 11173. This technique combines high-energy and low- energy scanning during a single acquisition. Six human urinary stones were scanned in vitro using 80 kV and 120 kV micro CT SkyScan 1173. Projected images were produced by micro CT SkyScan 1173 and then reconstructed using NRecon (in-house software from SkyScan) to obtain a complete 3D image. The urinary stone images were analysed using CT analyser to obtain information of internal structure and Hounsfield Unit (HU) values to determine the information regarding the composition of the urinary stones, respectively. HU values obtained from some regions of interest in the same slice are compared to a reference HU. The analysis shows information of the composition of the six scanned stones obtained. The six stones consist of stone number 1 (calcium+cystine), number 2 (calcium+struvite), number 3 (calcium+cystine+struvite), number 4 (calcium), number 5 (calcium+cystine+struvite), and number 6 (calcium+uric acid). This shows that dual energy micro CT SkyScan 1173 was able to characterize the composition of the urinary stone.

  7. Parametric boundary reconstruction algorithm for industrial CT metrology application.

    PubMed

    Yin, Zhye; Khare, Kedar; De Man, Bruno

    2009-01-01

    High-energy X-ray computed tomography (CT) systems have been recently used to produce high-resolution images in various nondestructive testing and evaluation (NDT/NDE) applications. The accuracy of the dimensional information extracted from CT images is rapidly approaching the accuracy achieved with a coordinate measuring machine (CMM), the conventional approach to acquire the metrology information directly. On the other hand, CT systems generate the sinogram which is transformed mathematically to the pixel-based images. The dimensional information of the scanned object is extracted later by performing edge detection on reconstructed CT images. The dimensional accuracy of this approach is limited by the grid size of the pixel-based representation of CT images since the edge detection is performed on the pixel grid. Moreover, reconstructed CT images usually display various artifacts due to the underlying physical process and resulting object boundaries from the edge detection fail to represent the true boundaries of the scanned object. In this paper, a novel algorithm to reconstruct the boundaries of an object with uniform material composition and uniform density is presented. There are three major benefits in the proposed approach. First, since the boundary parameters are reconstructed instead of image pixels, the complexity of the reconstruction algorithm is significantly reduced. The iterative approach, which can be computationally intensive, will be practical with the parametric boundary reconstruction. Second, the object of interest in metrology can be represented more directly and accurately by the boundary parameters instead of the image pixels. By eliminating the extra edge detection step, the overall dimensional accuracy and process time can be improved. Third, since the parametric reconstruction approach shares the boundary representation with other conventional metrology modalities such as CMM, boundary information from other modalities can be directly incorporated as prior knowledge to improve the convergence of an iterative approach. In this paper, the feasibility of parametric boundary reconstruction algorithm is demonstrated with both simple and complex simulated objects. Finally, the proposed algorithm is applied to the experimental industrial CT system data.

  8. Congenital bronchopulmonary malformation: CT histopathological correlation.

    PubMed

    Kyncl, Martin; Koci, Martin; Ptackova, Lea; Hornofova, Ludmila; Ondrej, Fabian; Snajdauf, Jiri; Pychova, Marcela

    2016-12-01

    This study evaluated the accuracy of postnatal computed tomography (CT) imaging in the identification of congenital bronchopulmonary malformation (BPM) in comparison with histopathological analysis. CT scans of prenatally diagnosed BPMs from 24 patients with available histology were analysed retrospectively. The CT images were reviewed blinded to histological findings by two radiologists. Specific diagnosis was assigned based on predetermined criteria. The accuracy of CT was evaluated. The agreement rate in CT diagnosis between two radiologists was 100%. In 75% the lesions were located in the lower lobes. An overlap of 71% in CT and histopathological diagnoses was reached. The least matching diagnosis was type 2 CPAM. Contrast enhanced chest CT is very accurate in characterizing the BPM spectrum and provides important information on lesion type and structure.

  9. Hybrid registration of PET/CT in thoracic region with pre-filtering PET sinogram

    NASA Astrophysics Data System (ADS)

    Mokri, S. S.; Saripan, M. I.; Marhaban, M. H.; Nordin, A. J.; Hashim, S.

    2015-11-01

    The integration of physiological (PET) and anatomical (CT) images in cancer delineation requires an accurate spatial registration technique. Although hybrid PET/CT scanner is used to co-register these images, significant misregistrations exist due to patient and respiratory/cardiac motions. This paper proposes a hybrid feature-intensity based registration technique for hybrid PET/CT scanner. First, simulated PET sinogram was filtered with a 3D hybrid mean-median before reconstructing the image. The features were then derived from the segmented structures (lung, heart and tumor) from both images. The registration was performed based on modified multi-modality demon registration with multiresolution scheme. Apart from visual observations improvements, the proposed registration technique increased the normalized mutual information index (NMI) between the PET/CT images after registration. All nine tested datasets show marked improvements in mutual information (MI) index than free form deformation (FFD) registration technique with the highest MI increase is 25%.

  10. Consequences of additional use of PET information for target volume delineation and radiotherapy dose distribution for esophageal cancer.

    PubMed

    Muijs, Christina T; Schreurs, Liesbeth M; Busz, Dianne M; Beukema, Jannet C; van der Borden, Arnout J; Pruim, Jan; Van der Jagt, Eric J; Plukker, John Th; Langendijk, Johannes A

    2009-12-01

    To determine the consequences of target volume (TV) modifications, based on the additional use of PET information, on radiation planning, assuming PET/CT-imaging represents the true extent of the tumour. For 21 patients with esophageal cancer, two separate TV's were retrospectively defined based on CT (CT-TV) and co-registered PET/CT images (PET/CT-TV). Two 3D-CRT plans (prescribed dose 50.4 Gy) were constructed to cover the corresponding TV's. Subsequently, these plans were compared for target coverage, normal tissue dose-volume histograms and the corresponding normal tissue complication probability (NTCP) values. The addition of PET led to the modification of CT-TV with at least 10% in 12 of 21 patients (57%) (reduction in 9, enlargement in 3). PET/CT-TV was inadequately covered by the CT-based treatment plan in 8 patients (36%). Treatment plan modifications resulted in significant changes (p<0.05) in dose distributions to heart and lungs. Corresponding changes in NTCP values ranged from -3% to +2% for radiation pneumonitis and from -0.2% to +1.2% for cardiac mortality. This study demonstrated that TV's based on CT might exclude PET-avid disease. Consequences are under dosing and thereby possibly ineffective treatment. Moreover, the addition of PET in radiation planning might result in clinical important changes in NTCP.

  11. [One-stage Operation through the Same Skin Incision for Synchronous Double Primary Breast and Lung Cancer;Report of a Case].

    PubMed

    Takahashi, Noriyuki; Kuga, Yoko; Uno, Satoko; Saito, Keita

    2018-02-01

    A 75-year-old woman noticed a small mass in the right side breast and consulted our hospital. The results of the detailed examination indicated the synchronous double primary right breast cancer and the same side lung cancer (rS5). One-stage operation from the same skin incision was scheduled. Volume rendering (VR) of computed tomography (CT)-scan was very useful in deciding the position and the length of the skin incision. The breast tumor resection and the right middle lobe resection were successfully performed through 6.5 cm skin incision.

  12. Adverse drug reaction: rosuvastatin as a cause for ischaemic colitis in a 64-year-old woman

    PubMed Central

    Tan, Jackie; Pretorius, Casper Francois; Flanagan, Paul Vincent; Pais, Antonio

    2012-01-01

    Rosuvastatin (Crestor, AstraZeneca) is a commonly used drug for managing hypercholesterolaemia. It is a very safe medication with mostly acceptable side effects. Rare but serious side effects are not well known. A 64-year-old woman presented with bloody diarrhoea after starting rosuvastatin for hypercholesterolaemia. Stool microscopy and culture ruled out infective causes. Abdominal CT scan revealed normal calibre celiac axis and superior mesenteric artery. Colonoscopic biopsy revealed ischaemic colitis as the final histological diagnosis. The patient is in complete remission after ceasing the medication. Rosuvastatin causing ischaemic colitis should be considered a rare but serious adverse drug reaction. PMID:22744258

  13. [Cavernous sinus thrombosis as a rare cause of exophthalmos in childhood : A case report].

    PubMed

    Kamawal, A; Schmidt, M A; Rompel, O; Gusek-Schneider, G C; Mardin, C Y; Trollmann, R

    2017-05-01

    Complications of acute bacterial sinusitis mostly occur in children and adolescents. In particular, intracranial spread of the infection can lead to severe even fatal courses of the disease. This article is a case report about a 13-year-old boy suffering from left-sided headache, meningismus and exophthalmos as presenting symptoms. Cranial magnetic resonance imaging (MRI) showed merely right-sided sphenoid sinusitis; however, the diffusion-weighted MRI sequence indicated a left-sided cavernous sinus thrombosis, which could be confirmed by computed tomography (CT) angiography. Cerebrospinal fluid diagnostics showed significant leukocytosis confirming secondary meningitis. Finally, exophthalmos was explained by parainfectious cavernous sinus thrombosis and periorbital edema. This case report highlights the importance of extended and specific diagnostic imaging in cases of clinically suspected complications in children and adolescents with sinusitis and the diagnostic significance of diffusion-weighted MRI.

  14. Brain CT image similarity retrieval method based on uncertain location graph.

    PubMed

    Pan, Haiwei; Li, Pengyuan; Li, Qing; Han, Qilong; Feng, Xiaoning; Gao, Linlin

    2014-03-01

    A number of brain computed tomography (CT) images stored in hospitals that contain valuable information should be shared to support computer-aided diagnosis systems. Finding the similar brain CT images from the brain CT image database can effectively help doctors diagnose based on the earlier cases. However, the similarity retrieval for brain CT images requires much higher accuracy than the general images. In this paper, a new model of uncertain location graph (ULG) is presented for brain CT image modeling and similarity retrieval. According to the characteristics of brain CT image, we propose a novel method to model brain CT image to ULG based on brain CT image texture. Then, a scheme for ULG similarity retrieval is introduced. Furthermore, an effective index structure is applied to reduce the searching time. Experimental results reveal that our method functions well on brain CT images similarity retrieval with higher accuracy and efficiency.

  15. Human identification based on cranial computed tomography scan — a case report

    PubMed Central

    Silva, RF; Botelho, TL; Prado, FB; Kawagushi, JT; Daruge Júnior, E; Bérzin, F

    2011-01-01

    Today, there is increasing use of CT scanning on a clinical basis, aiding in the diagnosis of diseases or injuries. This exam also provides important information that allows identification of individuals. This paper reports the use of a CT scan on the skull, taken when the victim was alive, for the positive identification of a victim of a traffic accident in which the fingerprint analysis was impossible. The authors emphasize that the CT scan is a tool primarily used in clinical diagnosis and may contribute significantly to forensic purpose, allowing the exploration of virtual corpses before the classic autopsy. The use of CT scans might increase the quantity and quality of information involved in the death of the person examined. PMID:21493883

  16. Unilateral microphthalmia or anophthalmia in eight pythons (Pythonidae).

    PubMed

    Da Silva, Mari-Ann O; Bertelsen, Mads F; Wang, Tobias; Pedersen, Michael; Lauridsen, Henrik; Heegaard, Steffen

    2015-01-01

    To provide morphological descriptions of microphthalmia or anophthalmia in eight pythons using microcomputerized tomography (μCT), magnetic resonance imaging (MRI), and histopathology. Seven Burmese pythons (Python bivittatus) and one ball python (P. regius) with clinically normal right eyes and an abnormal or missing left eye. At the time of euthanasia, four of the eight snakes underwent necropsy. Hereafter, the heads of two Burmese pythons and one ball python were examined using μCT, and another Burmese python was subjected to MRI. Following these procedures, the heads of these four pythons along with the heads of an additional three Burmese pythons were prepared for histology. All eight snakes had left ocular openings seen as dermal invaginations between 0.2 and 2.0 mm in diameter. They also had varying degrees of malformations of the orbital bones and a limited presence of nervous, glandular, and muscle tissue in the posterior orbit. Two individuals had small but identifiable eyes. Furthermore, remnants of the pigmented embryonic framework of the hyaloid vessels were found in the anophthalmic snakes. Necropsies revealed no other macroscopic anomalies. Eight pythons with unilateral left-sided microphthalmia or anophthalmia had one normal eye and a left orbit with malformed or incompletely developed ocular structures along with remnants of fetal structures. These cases lend further information to a condition that is often seen in snakes, but infrequently described. © 2014 American College of Veterinary Ophthalmologists.

  17. Experimental and Numerical Observations of Hydrate Reformation during Depressurization in a Core-Scale Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seol, Yongkoo; Myshakin, Evgeniy

    2011-01-01

    Gas hydrate has been predicted to reform around a wellbore during depressurization-based gas production from gas hydrate-bearing reservoirs. This process has an adverse effect on gas production rates and it requires time and sometimes special measures to resume gas flow to producing wells. Due to lack of applicable field data, laboratory scale experiments remain a valuable source of information to study hydrate reformation. In this work, we report laboratory experiments and complementary numerical simulations executed to investigate the hydrate reformation phenomenon. Gas production from a pressure vessel filled with hydrate-bearing sand was induced by depressurization with and without heat fluxmore » through the boundaries. Hydrate decomposition was monitored with a medical X-ray CT scanner and pressure and temperature measurements. CT images of the hydrate-bearing sample were processed to provide 3-dimensional data of heterogeneous porosity and phase saturations suitable for numerical simulations. In the experiments, gas hydrate reformation was observed only in the case of no-heat supply from surroundings, a finding consistent with numerical simulation. By allowing gas production on either side of the core, numerical simulations showed that initial hydrate distribution patterns affect gas distribution and flow inside the sample. This is a direct consequence of the heterogeneous pore network resulting in varying hydraulic properties of the hydrate-bearing sediment.« less

  18. Familial Cerebral Cavernous Malformations Are Associated with Adrenal Calcifications on CT Scans: An Imaging Biomarker for a Hereditary Cerebrovascular Condition.

    PubMed

    Strickland, Corinne D; Eberhardt, Steven C; Bartlett, Mary R; Nelson, Jeffrey; Kim, Helen; Morrison, Leslie A; Hart, Blaine L

    2017-08-01

    Purpose To determine if adrenal calcifications seen at computed tomography (CT) are associated with familial cerebral cavernous malformations (fCCMs) in carriers of the CCM1 Common Hispanic Mutation. Materials and Methods This study was approved by the institutional review board. The authors retrospectively reviewed abdominal CT scans in 38 patients with fCCM, 38 unaffected age- and sex-matched control subjects, and 13 patients with sporadic, nonfamilial cerebral cavernous malformation (CCM). The size, number, and laterality of calcifications and the morphologic characteristics of the adrenal gland were recorded. Brain lesion count was recorded from brain magnetic resonance (MR) imaging in patients with fCCM. The prevalence of adrenal calcifications in patients with fCCM was compared with that in unaffected control subjects and those with sporadic CCM by using the Fisher exact test. Additional analyses were performed to determine whether age and brain lesion count were associated with adrenal findings in patients with fCCM. Results Small focal calcifications (SFCs) (≤5 mm) were seen in one or both adrenal glands in 19 of the 38 patients with fCCM (50%), compared with 0 of the 38 unaffected control subjects (P < .001) and 0 of the 13 subjects with sporadic CCM (P = .001). Adrenal calcifications in patients with fCCM were more frequently left sided, with 17 of 19 patients having more SFCs in the left adrenal gland than the right adrenal gland and 50 of the 61 observed SFCs (82%) found in the left adrenal gland. No subjects had SFCs on the right side only. In patients with fCCM, the presence of SFCs showed a positive correlation with age (P < .001) and number of brain lesions (P < .001). Conclusion Adrenal calcifications identified on CT scans are common in patients with fCCM and may be a clinically silent manifestation of disease. © RSNA, 2017.

  19. A 2D threshold of the condylar-C1 interval to maximize identification of patients at high risk for atlantooccipital dislocation using computed tomography.

    PubMed

    Ravindra, Vijay M; Riva-Cambrin, Jay; Horn, Kevin P; Ginos, Jason; Brockmeyer, Russell; Guan, Jian; Rampton, John; Brockmeyer, Douglas L

    2017-04-01

    OBJECTIVE Measurement of the occipital condyle-C1 interval (CCI) is important in the evaluation of atlantooccipital dislocation (AOD) in pediatric trauma patients. The authors studied a large cohort of children with and without AOD to identify a 2D measurement threshold that maximizes the diagnostic yield of the CCI on cervical spine CT scans obtained in trauma patients. METHODS This retrospective, single-center study included all children who underwent CT of the cervical spine at Primary Children's Hospital from January 1, 2011, through December 31, 2014, for trauma evaluation. Bilateral CCI measurements in the coronal (3 measurements per side) and sagittal (4 measurements per side) planes were recorded. Using an iterative method, the authors determined optimal cutoffs for the maximal CCI in each plane in relation to AOD. The primary outcome was AOD requiring occipitocervical fusion. RESULTS A total of 597 pediatric patients underwent cervical spine CT for trauma evaluation: 578 patients without AOD and 19 patients with AOD requiring occipitocervical fusion. The authors found a statistically significant correlation between CCI and age (p < 0.001), with younger patients having higher CCIs. Using a 2D threshold requiring a sagittal CCI ≥ 2.5 mm and a coronal CCI ≥ 3.5 mm predicted AOD with a sensitivity of 95%, a specificity of 73%, positive predictive value of 10.3%, and negative predictive value of 99%. The accuracy of this 2D threshold was 84%. CONCLUSIONS In the present study population, age-dependent differences in the CCI were found on CT scans of the cervical spine in a large cohort of patients with and without AOD. A 2D CCI threshold as a screening method maximizes identification of patients at high risk for AOD while minimizing unnecessary imaging studies in children being evaluated for trauma.

  20. Polysplenia syndrome with duodenal and pancreatic dysplasia in a Holstein calf: a case report.

    PubMed

    Kondoh, Daisuke; Kawano, Tomomi; Kikuchi, Tomoaki; Hatate, Kaoru; Watanabe, Kenichi; Sasaki, Motoki; Yamagishi, Norio; Inokuma, Hisashi; Kitamura, Nobuo

    2017-09-29

    Laterality disorders of the abdominal organs include situs inversus totalis that mirrors the arrangements of all internal organs and heterotaxy syndrome (situs ambiguus) in which the thoracic or abdominal organs are abnormally arranged. Heterotaxy is often accompanied by multiple congenital malformations, and it generally comprises asplenia and polysplenia syndromes. To our knowledge, polysplenia syndrome has been reported in only three cattle, and computerized tomographic (CT) images of these animals were not obtained. A six-month-old Holstein heifer had ruminal tympani and right abdominal distension. CT imaging showed that the rumen occupied the right side of the abdominal cavity, the omasum and abomasum occupied the left ventral side and the liver was positioned on the left. The colon and cecum were located at the left dorsum of the cavity, and the left kidney was located more cranially than the right. Postmortem findings revealed two spleens attached to the rumen. Significantly, the duodenum was too short to be divided into segments, except the cranial and descending parts, or flexures, except the cranial flexure, and the pancreas, which lacked a left lobe, was covered with mesojejunum. The liver comprised a relatively large right lobe and a small left lobe without quadrate and caudate lobes. The caudal vena cava that connected to the left azygous vein passed irregularly through the aortic hiatus of the diaphragm, and the common hepatic vein without the caudal vena cava passed through the caval foramen. Although the lungs and heart were morphologically normal, the right atrium received three major systemic veins. Polysplenia syndrome was diagnosed based on the CT and postmortem findings. We defined the positions of the abdominal organs and morphological abnormalities in various organs of a calf with polysplenia syndrome based on CT and postmortem findings. These findings will improve understanding of the malpositioning and malformations that can occur in the organs of cattle with polysplenia syndrome.

  1. Visibility of an iron-containing fiducial marker in magnetic resonance imaging for high-precision external beam prostate radiotherapy.

    PubMed

    Tanaka, Osamu; Komeda, Hisao; Hirose, Shigeki; Taniguchi, Takuya; Ono, Kousei; Matsuo, Masayuki

    2017-11-29

    Visualization of fiducial gold markers is critical for registration on computed tomography (CT) and magnetic resonance imaging (MRI) for imaging-guided radiotherapy. Although larger markers provide better visualization on MRI, they tend to generate artifacts on CT. MRI is strongly influenced by the presence of metals, such as iron, in the body. Here we compared efficacies of a 0.5% iron-containing gold marker (GM) and a traditional non-iron-containing marker. Twenty-seven patients underwent CT/MRI fusion-based intensity-modulated radiotherapy. Markers were placed by urologists under local anesthesia. Gold Anchor (GA; diameter: 0.28 mm; length: 10 mm), an iron-containing marker, was placed on the right side of the prostate using a 22-G needle and VISICOIL (VIS; diameter: 0.35 mm; length: 10 mm), a non-iron-containing marker, was placed on the left side using a 19-G needle. T2*-weighted images MRI sequences were obtained. Two radiation oncologists and a radiation technologist evaluated and assigned scores for visual quality on a five-point scale (1, poor; 5, best visibility). Artifact generation on CT was slightly greater with GA than with VIS. The mean marker visualization scores on MRI of all three observers were significantly superior for GA than for VIS (3.5 vs 3.2, 3.9 vs 3.2, and 4.0 vs 2.9). The actual size of the spherical GA was about 2 mm in diameter, but the signal void on MRI was approximately 5 mm. Although both markers were well visualized and can be recommended clinically, the results suggest that GA has some subtle advantages for quantitative visualization that could prove useful in certain situations of stereotactic body radiotherapy and intensity-modulated radiotherapy. © 2017 John Wiley & Sons Australia, Ltd.

  2. The luciferin binding site residues C/T311 (S314) influence the bioluminescence color of beetle luciferases through main-chain interaction with oxyluciferin phenolate.

    PubMed

    Viviani, V R; Amaral, D T; Neves, D R; Simões, A; Arnoldi, F G C

    2013-01-08

    Beetle luciferases emit different bioluminescence colors from green to red; however, no clear relationship between the identity of the luciferin binding site residues and bioluminescence colors was found in different luciferases, and it is unclear whether critical interactions affecting emission spectra occur on the thiazolyl or on the benzothiazolyl sides of the luciferin binding site. Through homology modeling and site-directed mutagenesis using our multicolor set of beetle luciferases (Pyrearinus termitilluminans larval click beetle, Pte, λ(max) = 534 nm; Phrixothrix hirtus railroad worm red emitting, PxRE, λ(max) = 623 nm; and Macrolampis sp2 firefly, Mac, λ(max) = 564 nm), we show that the residues C/T311 (S314) play an important role in bioluminescence color determination. Modeling studies indicate that the main-chain carbonyls of these residues are close to both oxyluciferin phenolate and AMP, whereas the side chains pack against second-shell residues. The C311(S314)A mutation considerably red shifts the spectra of the green-yellow-emitting luciferases (Pte λ(max) = 534 to 590 nm; Mac λ(max) = 564 to 583/613 nm) and affects the K(M) values for luciferin and ATP, but not the spectrum of the red-emitting luciferase. On the other hand, whereas the exchange between C/T311 (S314) caused smaller effects on the emission spectra of green-yellow-emitting luciferases, the C311T substitution (naturally found in green-emitting railroad worm luciferases) resulted in the largest reported blue shift in P. hirtus red-emitting luciferase (λ(max) = 623 to 606 nm). Altogether, these results indicate that the stability of residues C/T311 (S314) and the size of the cavity around oxyluciferin phenolate affect bioluminescence colors and suggest, for the first time, the occurrence of a critical interaction between main-chain carbonyls of position 311 (314) residues and oxyluciferin phenolate.

  3. Low-dose dynamic myocardial perfusion CT image reconstruction using pre-contrast normal-dose CT scan induced structure tensor total variation regularization

    NASA Astrophysics Data System (ADS)

    Gong, Changfei; Han, Ce; Gan, Guanghui; Deng, Zhenxiang; Zhou, Yongqiang; Yi, Jinling; Zheng, Xiaomin; Xie, Congying; Jin, Xiance

    2017-04-01

    Dynamic myocardial perfusion CT (DMP-CT) imaging provides quantitative functional information for diagnosis and risk stratification of coronary artery disease by calculating myocardial perfusion hemodynamic parameter (MPHP) maps. However, the level of radiation delivered by dynamic sequential scan protocol can be potentially high. The purpose of this work is to develop a pre-contrast normal-dose scan induced structure tensor total variation regularization based on the penalized weighted least-squares (PWLS) criteria to improve the image quality of DMP-CT with a low-mAs CT acquisition. For simplicity, the present approach was termed as ‘PWLS-ndiSTV’. Specifically, the ndiSTV regularization takes into account the spatial-temporal structure information of DMP-CT data and further exploits the higher order derivatives of the objective images to enhance denoising performance. Subsequently, an effective optimization algorithm based on the split-Bregman approach was adopted to minimize the associative objective function. Evaluations with modified dynamic XCAT phantom and preclinical porcine datasets have demonstrated that the proposed PWLS-ndiSTV approach can achieve promising gains over other existing approaches in terms of noise-induced artifacts mitigation, edge details preservation, and accurate MPHP maps calculation.

  4. Changing Conspiracy Beliefs through Rationality and Ridiculing.

    PubMed

    Orosz, Gábor; Krekó, Péter; Paskuj, Benedek; Tóth-Király, István; Bőthe, Beáta; Roland-Lévy, Christine

    2016-01-01

    Conspiracy theory (CT) beliefs can be harmful. How is it possible to reduce them effectively? Three reduction strategies were tested in an online experiment using general and well-known CT beliefs on a comprehensive randomly assigned Hungarian sample ( N = 813): exposing rational counter CT arguments, ridiculing those who hold CT beliefs, and empathizing with the targets of CT beliefs. Several relevant individual differences were measured. Rational and ridiculing arguments were effective in reducing CT, whereas empathizing with the targets of CTs had no effect. Individual differences played no role in CT reduction, but the perceived intelligence and competence of the individual who conveyed the CT belief-reduction information contributed to the success of the CT belief reduction. Rational arguments targeting the link between the object of belief and its characteristics appear to be an effective tool in fighting conspiracy theory beliefs.

  5. SU-F-J-96: Comparison of Frame-Based and Mutual Information Registration Techniques for CT and MR Image Sets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Popple, R; Bredel, M; Brezovich, I

    Purpose: To compare the accuracy of CT-MR registration using a mutual information method with registration using a frame-based localizer box. Methods: Ten patients having the Leksell head frame and scanned with a modality specific localizer box were imported into the treatment planning system. The fiducial rods of the localizer box were contoured on both the MR and CT scans. The skull was contoured on the CT images. The MR and CT images were registered by two methods. The frame-based method used the transformation that minimized the mean square distance of the centroids of the contours of the fiducial rods frommore » a mathematical model of the localizer. The mutual information method used automated image registration tools in the TPS and was restricted to a volume-of-interest defined by the skull contours with a 5 mm margin. For each case, the two registrations were adjusted by two evaluation teams, each comprised of an experienced radiation oncologist and neurosurgeon, to optimize alignment in the region of the brainstem. The teams were blinded to the registration method. Results: The mean adjustment was 0.4 mm (range 0 to 2 mm) and 0.2 mm (range 0 to 1 mm) for the frame and mutual information methods, respectively. The median difference between the frame and mutual information registrations was 0.3 mm, but was not statistically significant using the Wilcoxon signed rank test (p=0.37). Conclusion: The difference between frame and mutual information registration techniques was neither statistically significant nor, for most applications, clinically important. These results suggest that mutual information is equivalent to frame-based image registration for radiosurgery. Work is ongoing to add additional evaluators and to assess the differences between evaluators.« less

  6. Multimodality Non-Rigid Image Registration for Planning, Targeting and Monitoring during CT-guided Percutaneous Liver Tumor Cryoablation

    PubMed Central

    Elhawary, Haytham; Oguro, Sota; Tuncali, Kemal; Morrison, Paul R.; Tatli, Servet; Shyn, Paul B.; Silverman, Stuart G.; Hata, Nobuhiko

    2010-01-01

    Rationale and Objectives To develop non-rigid image registration between pre-procedure contrast enhanced MR images and intra-procedure unenhanced CT images, to enhance tumor visualization and localization during CT-guided liver tumor cryoablation procedures. Materials and Methods After IRB approval, a non-rigid registration (NRR) technique was evaluated with different pre-processing steps and algorithm parameters and compared to a standard rigid registration (RR) approach. The Dice Similarity Coefficient (DSC), Target Registration Error (TRE), 95% Hausdorff distance (HD) and total registration time (minutes) were compared using a two-sided Student’s t-test. The entire registration method was then applied during five CT-guided liver cryoablation cases with the intra-procedural CT data transmitted directly from the CT scanner, with both accuracy and registration time evaluated. Results Selected optimal parameters for registration were section thickness of 5mm, cropping the field of view to 66% of its original size, manual segmentation of the liver, B-spline control grid of 5×5×5 and spatial sampling of 50,000 pixels. Mean 95% HD of 3.3mm (2.5x improvement compared to RR, p<0.05); mean DSC metric of 0.97 (13% increase); and mean TRE of 4.1mm (2.7x reduction) were measured. During the cryoablation procedure registration between the pre-procedure MR and the planning intra-procedure CT took a mean time of 10.6 minutes, the MR to targeting CT image took 4 minutes and MR to monitoring CT took 4.3 minutes. Mean registration accuracy was under 3.4mm. Conclusion Non-rigid registration allowed improved visualization of the tumor during interventional planning, targeting and evaluation of tumor coverage by the ice ball. Future work is focused on reducing segmentation time to make the method more clinically acceptable. PMID:20817574

  7. Comparison between adrenal venous sampling and computed tomography in the diagnosis of primary aldosteronism and in the guidance of adrenalectomy

    PubMed Central

    Zhu, Limin; Zhang, Ying; Zhang, Hua; Zhou, Wenlong; Shen, Zhoujun; Zheng, Fangfang; Tang, Xiaofeng; Tao, Bo; Zhang, Jin; Lu, Xiaohong; Xu, Jianzhong; Chu, Shaoli; Zhu, Dingliang; Gao, Pingjin; Wang, Ji-Guang

    2016-01-01

    Abstract In our series of patients with primary aldosteronism, we compared diagnostic concordance and clinical outcomes after adrenalectomy between adrenal venous sampling (AVS) and computed tomography (CT) imaging. Our retrospective analysis included 886 patients with primary aldosteronism diagnosed in our hospital between 2005 and 2014. Of them, 269 patients with CT unilateral adrenal disease were included in the analysis on the diagnostic concordance and 126 patients with follow-up data in the analysis on clinical outcomes after adrenalectomy. Hypertension was considered cured if systolic/diastolic blood pressure (BP) was controlled (<140/90 mm Hg) without medication and improved if BP was controlled with a reduced number of antihypertensive drugs. In 269 patients with CT unilateral adrenal disease, the overall concordance rate between AVS and CT was 50.5% for lateralization on the same side. The concordance rate decreased with increasing age, with highest rate of 61% in patients aged <30 years (n = 16). In 126 patients with follow-up data after adrenalectomy, the AVS- (n = 96) and CT-guided patients (n = 30) had similar characteristics before adrenalectomy. After andrenalectomy, the AVS-guided patients had a significantly higher serum potassium concentration (4.3 ± 0.3 vs 4.0 ± 0.5 mmol/L, P = 0.04) and rate of cured and improved hypertension (98% vs 87%, P = 0.03). The AVS-guided patients (n = 50) had slightly higher cured rate than the CT-guided patients (n = 11) in those older than 50 years (26.0% vs 18.2%, P = 0.72). The age below which the cured rate in the CT-guided patients was 100% was 30 years. AVS guidance had moderate concordance with CT and slightly improved clinical outcomes after adrenalectomy. The age below which CT unilateralization achieved 100% cured rate was approximately 30 years. PMID:27684853

  8. A combined learning algorithm for prostate segmentation on 3D CT images.

    PubMed

    Ma, Ling; Guo, Rongrong; Zhang, Guoyi; Schuster, David M; Fei, Baowei

    2017-11-01

    Segmentation of the prostate on CT images has many applications in the diagnosis and treatment of prostate cancer. Because of the low soft-tissue contrast on CT images, prostate segmentation is a challenging task. A learning-based segmentation method is proposed for the prostate on three-dimensional (3D) CT images. We combine population-based and patient-based learning methods for segmenting the prostate on CT images. Population data can provide useful information to guide the segmentation processing. Because of inter-patient variations, patient-specific information is particularly useful to improve the segmentation accuracy for an individual patient. In this study, we combine a population learning method and a patient-specific learning method to improve the robustness of prostate segmentation on CT images. We train a population model based on the data from a group of prostate patients. We also train a patient-specific model based on the data of the individual patient and incorporate the information as marked by the user interaction into the segmentation processing. We calculate the similarity between the two models to obtain applicable population and patient-specific knowledge to compute the likelihood of a pixel belonging to the prostate tissue. A new adaptive threshold method is developed to convert the likelihood image into a binary image of the prostate, and thus complete the segmentation of the gland on CT images. The proposed learning-based segmentation algorithm was validated using 3D CT volumes of 92 patients. All of the CT image volumes were manually segmented independently three times by two, clinically experienced radiologists and the manual segmentation results served as the gold standard for evaluation. The experimental results show that the segmentation method achieved a Dice similarity coefficient of 87.18 ± 2.99%, compared to the manual segmentation. By combining the population learning and patient-specific learning methods, the proposed method is effective for segmenting the prostate on 3D CT images. The prostate CT segmentation method can be used in various applications including volume measurement and treatment planning of the prostate. © 2017 American Association of Physicists in Medicine.

  9. [CT morphometry for calcaneal fractures and comparison of the Zwipp and Sanders classifications].

    PubMed

    Andermahr, J; Jesch, A B; Helling, H J; Jubel, A; Fischbach, R; Rehm, K E

    2002-01-01

    The aim of the study is to correlate the CT-morphological changes of fractured calcaneus and the classifications of Zwipp and Sanders with the clinical outcome. In a retrospective clinical study, the preoperative CT scans of 75 calcaneal fractures were analysed. The morphometry of the fractures was determined by measuring height, length diameter and calcaneo-cuboidal angle in comparison to the intact contralateral side. At a mean of 38 months after trauma 44 patients were clinically followed-up. The data of CT image morphometry were correlated with the severity of fracture classified by Zwipp or Sanders as well as with the functional outcome. There was a good correlation between the fracture classifications and the morphometric data. Both fracture classifying systems have a predictive impact for functional outcome. The more exacting and accurate Zwipp classification considers the most important cofactors like involvement of the calcaneo-cuboidal joint, soft tissue damage, additional fractures etc. The Sanders classification is easier to use during clinical routine. The Zwipp classification includes more relevant cofactors (fracture of the calcaneo-cuboidal-joint, soft tissue swelling, etc.) and presents a higher correlation to the choice of therapy. Both classification systems present a prognostic impact concerning the clinical outcome.

  10. Registration of PET and CT images based on multiresolution gradient of mutual information demons algorithm for positioning esophageal cancer patients.

    PubMed

    Jin, Shuo; Li, Dengwang; Wang, Hongjun; Yin, Yong

    2013-01-07

    Accurate registration of 18F-FDG PET (positron emission tomography) and CT (computed tomography) images has important clinical significance in radiation oncology. PET and CT images are acquired from (18)F-FDG PET/CT scanner, but the two acquisition processes are separate and take a long time. As a result, there are position errors in global and deformable errors in local caused by respiratory movement or organ peristalsis. The purpose of this work was to implement and validate a deformable CT to PET image registration method in esophageal cancer to eventually facilitate accurate positioning the tumor target on CT, and improve the accuracy of radiation therapy. Global registration was firstly utilized to preprocess position errors between PET and CT images, achieving the purpose of aligning these two images on the whole. Demons algorithm, based on optical flow field, has the features of fast process speed and high accuracy, and the gradient of mutual information-based demons (GMI demons) algorithm adds an additional external force based on the gradient of mutual information (GMI) between two images, which is suitable for multimodality images registration. In this paper, GMI demons algorithm was used to achieve local deformable registration of PET and CT images, which can effectively reduce errors between internal organs. In addition, to speed up the registration process, maintain its robustness, and avoid the local extremum, multiresolution image pyramid structure was used before deformable registration. By quantitatively and qualitatively analyzing cases with esophageal cancer, the registration scheme proposed in this paper can improve registration accuracy and speed, which is helpful for precisely positioning tumor target and developing the radiation treatment planning in clinical radiation therapy application.

  11. A minimum spanning forest based classification method for dedicated breast CT images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pike, Robert; Sechopoulos, Ioannis; Fei, Baowei, E-mail: bfei@emory.edu

    Purpose: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. Methods: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bilateral filter to reduce noise while keeping edge information and were corrected to overcome cupping artifacts. As skin and glandular tissue have similar CT values on breast CT images, morphologic processing is used to identify the skin based on its position information. A support vector machine (SVM) is trained and the resulting modelmore » used to create a pixelwise classification map of fat and glandular tissue. By combining the results of the skin mask with the SVM results, the breast tissue is classified as skin, fat, and glandular tissue. This map is then used to identify markers for a minimum spanning forest that is grown to segment the image using spatial and intensity information. To evaluate the authors’ classification method, they use DICE overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on five patient images. Results: Comparison between the automatic and the manual segmentation shows that the minimum spanning forest based classification method was able to successfully classify dedicated breast CT image with average DICE ratios of 96.9%, 89.8%, and 89.5% for fat, glandular, and skin tissue, respectively. Conclusions: A 2D minimum spanning forest based classification method was proposed and evaluated for classifying the fat, skin, and glandular tissue in dedicated breast CT images. The classification method can be used for dense breast tissue quantification, radiation dose assessment, and other applications in breast imaging.« less

  12. Automated extraction of radiation dose information from CT dose report images.

    PubMed

    Li, Xinhua; Zhang, Da; Liu, Bob

    2011-06-01

    The purpose of this article is to describe the development of an automated tool for retrieving texts from CT dose report images. Optical character recognition was adopted to perform text recognitions of CT dose report images. The developed tool is able to automate the process of analyzing multiple CT examinations, including text recognition, parsing, error correction, and exporting data to spreadsheets. The results were precise for total dose-length product (DLP) and were about 95% accurate for CT dose index and DLP of scanned series.

  13. Extraction of CT dose information from DICOM metadata: automated Matlab-based approach.

    PubMed

    Dave, Jaydev K; Gingold, Eric L

    2013-01-01

    The purpose of this study was to extract exposure parameters and dose-relevant indexes of CT examinations from information embedded in DICOM metadata. DICOM dose report files were identified and retrieved from a PACS. An automated software program was used to extract from these files information from the structured elements in the DICOM metadata relevant to exposure. Extracting information from DICOM metadata eliminated potential errors inherent in techniques based on optical character recognition, yielding 100% accuracy.

  14. 18F-FDG PET/MRI fusion in characterizing pancreatic tumors: comparison to PET/CT.

    PubMed

    Tatsumi, Mitsuaki; Isohashi, Kayako; Onishi, Hiromitsu; Hori, Masatoshi; Kim, Tonsok; Higuchi, Ichiro; Inoue, Atsuo; Shimosegawa, Eku; Takeda, Yutaka; Hatazawa, Jun

    2011-08-01

    To demonstrate that positron emission tomography (PET)/magnetic resonance imaging (MRI) fusion was feasible in characterizing pancreatic tumors (PTs), comparing MRI and computed tomography (CT) as mapping images for fusion with PET as well as fused PET/MRI and PET/CT. We retrospectively reviewed 47 sets of (18)F-fluorodeoxyglucose ((18)F -FDG) PET/CT and MRI examinations to evaluate suspected or known pancreatic cancer. To assess the ability of mapping images for fusion with PET, CT (of PET/CT), T1- and T2-weighted (w) MR images (all non-contrast) were graded regarding the visibility of PT (5-point confidence scale). Fused PET/CT, PET/T1-w or T2-w MR images of the upper abdomen were evaluated to determine whether mapping images provided additional diagnostic information to PET alone (3-point scale). The overall quality of PET/CT or PET/MRI sets in diagnosis was also assessed (3-point scale). These PET/MRI-related scores were compared to PET/CT-related scores and the accuracy in characterizing PTs was compared. Forty-three PTs were visualized on CT or MRI, including 30 with abnormal FDG uptake and 13 without. The confidence score for the visibility of PT was significantly higher on T1-w MRI than CT. The scores for additional diagnostic information to PET and overall quality of each image set in diagnosis were significantly higher on the PET/T1-w MRI set than the PET/CT set. The diagnostic accuracy was higher on PET/T1-w or PET/T2-w MRI (93.0 and 90.7%, respectively) than PET/CT (88.4%), but statistical significance was not obtained. PET/MRI fusion, especially PET with T1-w MRI, was demonstrated to be superior to PET/CT in characterizing PTs, offering better mapping and fusion image quality.

  15. Comparison of Morphological Characteristics of the Subaxial Cervical Spine between Athetoid Cerebral Palsy and Normal Control.

    PubMed

    Kim, Jun Young; Kwon, Jae Yeol; Kim, Moon Seok; Lee, Jeong Jae; Kim, Il Sup; Hong, Jae Taek

    2018-03-01

    To compare the morphometry of subaxial cervical spine between cerebral palsy (CP) and normal control. We retrospectively analyzed 72 patients with CP, as well as 72 patients from normal population. The two groups were matched for age, sex, and body mass index. Pedicle, lateral mass (LM), and vertebral foramen were evaluated using computed tomography (CT) imaging. Pedicle diameter, LM height, thickness, width and vertebral foramen asymmetry (VFA) were measured and compared between the two groups. Cervical dynamic motion, disc and facet joint degeneration were investigated. Additionally, we compared the morphology of LM between convex side and concave side with cervical scoliotic CP patients. LM height was smaller in CP group. LM thickness and width were larger in CP group at mid-cervical level. In 40 CP patients with cervical scoliosis, there were no height and width differences between convex and concave side. Pedicle outer diameter was not statistically different between two groups. Pedicle inner diameter was significantly smaller in CP group. Pedicle sclerosis was more frequent in CP patients. VFA was larger in CP group at C3, C4, and C5. Disc/facet degeneration grade was higher in the CP group. Cervical motion of CP group was smaller than those of the control group. LM morphology of CP patients was different from normal population. Sclerotic pedicles and vertebral foramen asymmetry were more commonly identified in CP patients. CP patients were more likely to demonstrate progressive disc/facet degeneration. This data may provide useful information on cervical posterior instrumentation in CP patients.

  16. 7. Photographic copy of color photograph of NUWC from the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Photographic copy of color photograph of NUWC from the Thames River, 1988, view northwest. Original color negative no. N0211-SP-88(L)-02389.16 on file at photo lab at NUWC, Newport, R.I. Copyright-free. - Naval Undersea Warfare Center, East side of Smith & East Streets between Columbia & South Coves, New London, New London County, CT

  17. 8. Photographic copy of color photograph of NUWC from the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Photographic copy of color photograph of NUWC from the Thames River, 1988, view southeast. Original color negative no. N0211-SP-88(L)-02389.4 on file at photo lab at NUWC, Newport, R.I. Copyright-free. - Naval Undersea Warfare Center, East side of Smith & East Streets between Columbia & South Coves, New London, New London County, CT

  18. View east along Wolf Den Road showing residences on the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View east along Wolf Den Road showing residences on the north side of the road - Brooklyn Green, North Green, South Green, & West Green, parts of Brown Road, Canterbury Road (Route 169), Hartford Road (Route 6), Hyde Road, Pomfret Road (Route 169), Prince Hill Road, Providence Road (Route 6), Wauregan Road (Routes 169 & 205), & Wolf Den Road, Brooklyn, Windham County, CT

  19. View northwest along Wolf Den Road showing residences on the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View northwest along Wolf Den Road showing residences on the north side of the road - Brooklyn Green, North Green, South Green, & West Green, parts of Brown Road, Canterbury Road (Route 169), Hartford Road (Route 6), Hyde Road, Pomfret Road (Route 169), Prince Hill Road, Providence Road (Route 6), Wauregan Road (Routes 169 & 205), & Wolf Den Road, Brooklyn, Windham County, CT

  20. 10. View south at base of smokestack. Note monitor roof ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. View south at base of smokestack. Note monitor roof and laboratory on filtration bed at rear of photograph. (Across Armory Street). Cylindrical object at lower center is a muffler for the turbine powered stand-by generator unit. - Lake Whitney Water Filtration Plant, Armory Street Pumphouse, North side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stancanello, Joseph; Cavedon, Carlo; Francescon, Paolo

    Functional magnetic resonance imaging (fMRI) is used to distinguish areas of the brain responsible for different tasks and functions. It is possible, for example, by using fMRI images, to identify particular regions in the brain which can be considered as 'functional organs at risk' (fOARs), i.e., regions which would cause significant patient morbidity if compromised. The aim of this study is to propose and validate a method to exploit functional information for the identification of fOARs in CyberKnife (Accuray, Inc., Sunnyvale, CA) radiosurgery treatment planning; in particular, given the high spatial accuracy offered by the CyberKnife system, local nonrigid registrationmore » is used to reach accurate image matching. Five patients affected by arteriovenous malformations (AVMs) and scheduled to undergo radiosurgery were scanned prior to treatment using computed tomography (CT), three-dimensional (3D) rotational angiography (3DRA), T2 weighted and blood oxygenation level dependent echo planar imaging MRI. Tasks were chosen on the basis of lesion location by considering those areas which could be potentially close to treatment targets. Functional data were superimposed on 3DRA and CT used for treatment planning. The procedure for the localization of fMRI areas was validated by direct cortical stimulation on 38 AVM and tumor patients undergoing conventional surgery. Treatment plans studied with and without considering fOARs were significantly different, in particular with respect to both maximum dose and dose volume histograms; consideration of the fOARs allowed quality indices of treatment plans to remain almost constant or to improve in four out of five cases compared to plans with no consideration of fOARs. In conclusion, the presented method provides an accurate tool for the integration of functional information into AVM radiosurgery, which might help to minimize undesirable side effects and to make radiosurgery less invasive.« less

  2. Periportal low attenuation associated with liver metastasis from colorectal cancer: evaluation using multi-detector-row CT with pathological correlation.

    PubMed

    Takaji, Ryo; Matsumoto, Shunro; Kiyonaga, Maki; Yamada, Yasunari; Mori, Hiromu; Iwashita, Yukio; Ohta, Masayuki; Inomata, Masafumi; Hijiya, Naoki; Moriyama, Masatsugu; Takaki, Hajime; Fukuzawa, Kengo; Yonemasu, Hirotoshi

    2017-01-01

    Periportal low attenuation (PPLA) associated with metastatic liver cancer is occasionally seen on multi-detector-row CT (MDCT). The purpose of this study was to investigate the MDCT patterns of the PPLA and to correlate it with pathological findings. We retrospectively reviewed the MDCT images of 63 patients with metastatic liver cancers from colorectal adenocarcinoma. On MDCT scans, PPLA associated with liver metastasis was visualized in six patients with colorectal cancer. In these six patients who had undergone surgical resection, the radiologic-pathologic correlation was analyzed. All patients underwent a single contrast-enhanced MDCT within 1 month before surgical resection. The six liver cancers were pathologically proven to be moderately differentiated adenocarcinoma. We assessed the PPLA on MDCT concerning the distribution patterns and contrast enhancement with pathological correlation. In five of the patients, the PPLA extended to the hilar side from metastatic liver cancer. Pathologically, there was no cancer invasion into the intra-hepatic periportal area; however, massive lymphedema and fibrosis occurred in all six cases. PPLA on the hilar and peripheral sides of hepatic metastasis from colorectal cancer may be present suggesting lymphedema and fibrosis of portal tracts not always indicating cancer infiltration.

  3. Charge Separation Mechanisms in Ordered Films of Self-Assembled Donor–Acceptor Dyad Ribbons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Logsdon, Jenna L.; Hartnett, Patrick E.; Nelson, Jordan N.

    2017-04-21

    Orthogonal attachment of polar and nonpolar side-chains to a zinc porphyrin-perylenediimide dyad (ZnP-PDI, 1a) is shown to result in self-assembly of ordered supramolecular ribbons in which the ZnP and PDI molecules form segregated π-stacked columns. Following photoexcitation of the ordered ribbons, ZnP+•-PDI–• radical ion pairs form in <200 fs and subsequently produce a 30 ± 3% yield of free charge carriers that live for about 100 μs. Elongating the side chains on ZnP and PDI in 1b enhances the order of the films, but does not result in an increase in free charge carrier yield. In addition, this yield ismore » independent of temperature, free energy of reaction, and the ZnP-PDI distance in the covalent dyad. These results suggest that the free charge carrier yield in this system is not limited by a bound charge transfer (CT) state or promoted by a vibronically hot CT state. Instead, it is likely that π-stacking of the segregated donors and acceptors within the ribbons results in delocalization of the charges following photoexcitation, allowing them to overcome Coulombic attraction and generate free charge carriers.« less

  4. High level cross of the esophagus with the descending aorta in scoliosis: CT study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takahashi, Koji; Kikuno, Motoyuki; Hyodoh, Hideki

    1996-05-01

    The esophagus occasionally crosses the descending aorta at an unusually high level (3-5 cm inferior to the carina) in right-sided scoliosis. The purpose of this study was to analyze the mechanism of this finding. We prospectively evaluated thoracic CT scans in 30 patients with right-sided scoliosis. We assessed the alterations in the positions of the esophagus and the descending aorta by the thoracic deformity. The descending aorta followed the scoliotic curve of the spine in 26 (87%) patients. The esophagus followed the scoliotic curve of the spine in 14 (47%) patients and did not in 16 (53%). The anteroposterior diametermore » of the thorax in the former group was significantly smaller than that in the latter (p < 0.01). High level cross of both structures was identified in 14 (47%) patients, and all of them belonged to the group in which the esophagus did not follow the scoliotic curve of the spine. The unusual high level cross of the esophagus with the descending aorta occasionally seen in scoliosis is due to a difference in the positional alterations of the two structures resulting from the scoliosis. 6 refs., 3 figs.« less

  5. Diagnosis of Grave's disease with pulmonary hypertension on chest CT.

    PubMed

    Lee, Hwa Yeon; Yoo, Seung Min; Kim, Hye Rin; Chun, Eun Ju; White, Charles S

    To evaluate the diagnostic accuracy of chest CT findings to diagnose Grave's disease in pulmonary hypertension. We retrospectively evaluated chest CT and the medical records of 13 patients with Grave's disease with (n=6) or without pulmonary hypertension (n=7) and in 17 control patients. Presence of iso-attenuation of diffusely enlarged thyroid glands compared with adjacent neck muscle on non-enhanced CT as a diagnostic clue of Grave's disease, and assessment of pulmonary hypertension on CT has high diagnostic accuracy. Chest CT has the potential to diagnose Grave's disease with pulmonary hypertension in the absence of other information. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Radiological Findings in a case of Advance staged Mesothelioma

    PubMed Central

    Aziz, Fahad

    2009-01-01

    Chest X Ray is the initial screening test for the mesothelioma like all other the chest diseases. But computed tomography (CT) is the imaging technique of choice for charactering pleural masses. CT also gives important information regarding invasion of the chest wall and surrounding structures. Certain CT features help differentiate benign from malignant processes. This short article highlights the salient CT appearance of mesothelioma; the most common pleural tumor. PMID:22263002

  7. Two- and Three-Dimensional Anatomy of Paranasal Sinuses in Arabian Foals

    PubMed Central

    BAHAR, Sadullah; BOLAT, Durmus; DAYAN, Mustafa Orhun; PAKSOY, Yahya

    2013-01-01

    ABSTRACT The 2- and 3-dimensional (3D) anatomy and the morphometric properties of the paranasal sinuses of the foal have received little or no attention in the literature. The aim of this study was to obtain details of the paranasal sinuses using multiplane CT imaging to create 3D models and to determine morphological and morphometric data for the sinuses using the 3D models. The heads of five female foals were used in this study. The heads were scanned using computed tomography (CT) in the rostrocaudal direction. After the heads had been frozen, anatomical sections were obtained in the scan position. The 3D models of sinuses and the skull were prepared using MIMICS®. These models were used to assess the surface area and volume of the sinuses, the width, height and orientation of the apertures connecting these sinuses and finally the planar relation of the sinuses with the skull. The right and left sides of all anatomical structures, except the sphenoid sinuses, had symmetric organization on CT images and anatomical sections. The total sinus surface area and volume on both sides were 214.4 cm2 and 72.9 ml, respectively. The largest and the smallest sinuses were the frontal sinus (41.5 ml) and the middle conchal sinus (0.2 ml), respectively. It was found that the planes bounding the sinuses passed through easily palpable points on the head. In conclusion, 3D modeling in combination with conventional sectional imaging of the paranasal sinuses of the foal may help anatomists, radiologists, clinicians and veterinary students. PMID:24004969

  8. Two- and three-dimensional anatomy of paranasal sinuses in Arabian foals.

    PubMed

    Bahar, Sadullah; Bolat, Durmus; Dayan, Mustafa Orhun; Paksoy, Yahya

    2014-01-01

    The 2- and 3-dimensional (3D) anatomy and the morphometric properties of the paranasal sinuses of the foal have received little or no attention in the literature. The aim of this study was to obtain details of the paranasal sinuses using multiplane CT imaging to create 3D models and to determine morphological and morphometric data for the sinuses using the 3D models. The heads of five female foals were used in this study. The heads were scanned using computed tomography (CT) in the rostrocaudal direction. After the heads had been frozen, anatomical sections were obtained in the scan position. The 3D models of sinuses and the skull were prepared using MIMICS(®). These models were used to assess the surface area and volume of the sinuses, the width, height and orientation of the apertures connecting these sinuses and finally the planar relation of the sinuses with the skull. The right and left sides of all anatomical structures, except the sphenoid sinuses, had symmetric organization on CT images and anatomical sections. The total sinus surface area and volume on both sides were 214.4 cm(2) and 72.9 ml, respectively. The largest and the smallest sinuses were the frontal sinus (41.5 ml) and the middle conchal sinus (0.2 ml), respectively. It was found that the planes bounding the sinuses passed through easily palpable points on the head. In conclusion, 3D modeling in combination with conventional sectional imaging of the paranasal sinuses of the foal may help anatomists, radiologists, clinicians and veterinary students.

  9. [Anatomical and computed tomographic analysis of the interaction between uncinate process and agger nasi cells].

    PubMed

    Zhang, Luo; Han, De-min; Ge, Wen-tong; Zhou, Bing; Xian, Jun-fang; Liu, Zhong-yan; Wang, Kui-ji; He, Fei

    2005-12-01

    To investigate the anatomical interaction between uncinate process and agger nasi cell to better understand the anatomy of the frontal sinus drainage pathway by endoscopy, spiral computed tomography (CT) and sectioning. Twenty-one skeletal skulls (forty-two sides) and one cadaver head (two sides) were studied by spiral CT together with endoscopy and collodion embedded thin sectioning at coronal plane. The sections with the thickness of 100 microm were stained with hemotoxylin and eosin. Under endoscopy, a leaflet of bone to the middle turbinate, which is given off by uncinate process, forms the anterior insertion of the middle turbinate onto the lateral nasal wall. The middle portion of the uncinate process attached to the frontal process of the maxilla in all of the skeletal nasal cavities, as well as the lacrimal bone in 78.6% of the skeletal nasal cavities. On CT scans, the agger nasi cell is present in 90.5% of the skeletal nasal cavities. While the lateral wall of the agger nasi cell is formed by lacrimal bone, the medial wall of the agger nasi cell is formed by uncinate process. And the anterior wall is formed by the frontal process of the maxilla. The superior portion of the uncinate process forms the medial, posterior and top wall of the agger nasi cells. The superior portion of the uncinate extends into the frontal recess and may insert into lamina papyracea (33.3%), skull base (9.5%), middle turbinate, combination of these (57.2%). The agger nasi cell is the key that unlocks the frontal recess.

  10. Evaluation of bowel distension and mural visualisation using neutral oral contrast agents for multidetector-row computed tomography.

    PubMed

    Lim, Bee Kuan; Bux, Shaik Ismail; Rahmat, Kartini; Lam, Sze Yin; Liew, Yew Wai

    2012-11-01

    We compared the effectiveness of different types of non-commercial neutral oral contrast agents for bowel distension and mural visualisation in computed tomographic (CT) enterography. 90 consecutive patients from a group of 108 were randomly assigned to receive water (n = 30), 3.8% milk (n = 30) or 0.1% gastrografin (n = 30) as oral contrast agent. The results were independently reviewed by two radiologists who were blinded to the contrast agents used. The degree of bowel distension was qualitatively scored on a four-point scale. The discrimination of bowel loops, mural visualisation and visualisation of mucosal folds were evaluated on a 'yes' or 'no' basis. Side effects of the various agents were also recorded. 3.8% milk was significantly superior to water for bowel distension (jejunum, ileum and terminal ileum), discrimination of bowel loops (jejunum and ileum), mural visualisation and visualisation of mucosal folds (ileum and terminal ileum). It was also significantly superior to 0.1% gastrografin for bowel distension, discrimination of bowel loops, mural visualisation and visualisation of mucosal folds (jejunum, ileum and terminal ileum). However, 10% of patients who received 3.8% milk reported immediate post-test diarrhoea. No side effects were documented for patients who received water and 0.1% gastrografin. 3.8% milk is an effective and superior neutral oral contrast agent for the assessment of the jejunum, ileum and terminal ileum in CT enterography. However, further studies are needed to explore other suitable oral contrast agents for CT enterography in lactose- or cow's milk-intolerant patients.

  11. Lung PET scan

    MedlinePlus

    ... PET - chest; PET - lung; PET - tumor imaging; PET/CT - lung; Solitary pulmonary nodule - PET ... minutes. PET scans are performed along with a CT scan. This is because the combined information from ...

  12. How Is Testicular Cancer Diagnosed?

    MedlinePlus

    ... patients with non-seminoma. Many centers have special machines that can do both a PET and CT scan at the same time (PET/CT scan). This lets the doctor compare areas of higher radioactivity on the PET with the more detailed images of the CT. Bone scan A bone scan can help show if a ... Information, ...

  13. Supervisee Countertransference: A Holistic Supervision Approach

    ERIC Educational Resources Information Center

    Ponton, Richard F.; Sauerheber, Jill Duba

    2014-01-01

    Countertransference (CT) has been recognized as a significant variable in the process and outcome of therapy and counseling for over 100 years. A review of the literature suggests that little attention has been devoted to strategies that supervisors can use to address CT in supervision with novice counselors. Informed by models of CT proposed by…

  14. Paleoradiology: advanced CT in the evaluation of nine Egyptian mummies.

    PubMed

    Hoffman, Heidi; Torres, William E; Ernst, Randy D

    2002-01-01

    Axial thin-collimation state-of-the-art spiral computed tomography (CT) was combined with sagittal and coronal reformatting, three-dimensional (3D) reconstruction, and virtual "fly-through" techniques to nondestructively study nine Egyptian mummies. These techniques provided important paleopathologic and historical information about mummification techniques, depicted anatomy in the most informative imaging plane, illustrated the soft-tissue preservation and physical appearance of mummies in superb detail, and generated an intriguing virtual tour through hollow mummified remains without harming the specimens themselves. Images generated with these methods can help archaeologists and Egyptologists understand these fascinating members of mankind and can serve as adjunct visual aids for laypersons who are interested in mummies. CT has emerged as the imaging modality of choice for the examination of Egyptian mummies due to its noninvasive cross-sectional nature and inherently superior contrast and spatial resolution. As multi-detector row CT and postprocessing tools evolve, the capabilities and applications of CT will continue to proliferate, attesting to the expanded versatility and utility of CT as a noninvasive research tool in the multidisciplinary study of Egyptian mummies. Copyright RSNA, 2002

  15. DICOM structured report to track patient's radiation dose to organs from abdominal CT exam

    NASA Astrophysics Data System (ADS)

    Morioka, Craig; Turner, Adam; McNitt-Gray, Michael; Zankl, Maria; Meng, Frank; El-Saden, Suzie

    2011-03-01

    The dramatic increase of diagnostic imaging capabilities over the past decade has contributed to increased radiation exposure to patient populations. Several factors have contributed to the increase in imaging procedures: wider availability of imaging modalities, increase in technical capabilities, rise in demand by patients and clinicians, favorable reimbursement, and lack of guidelines to control utilization. The primary focus of this research is to provide in depth information about radiation doses that patients receive as a result of CT exams, with the initial investigation involving abdominal CT exams. Current dose measurement methods (i.e. CTDIvol Computed Tomography Dose Index) do not provide direct information about a patient's organ dose. We have developed a method to determine CTDIvol normalized organ doses using a set of organ specific exponential regression equations. These exponential equations along with measured CTDIvol are used to calculate organ dose estimates from abdominal CT scans for eight different patient models. For each patient, organ dose and CTDIvol were estimated for an abdominal CT scan. We then modified the DICOM Radiation Dose Structured Report (RDSR) to store the pertinent patient information on radiation dose to their abdominal organs.

  16. Review of an initial experience with an experimental spectral photon-counting computed tomography system

    NASA Astrophysics Data System (ADS)

    Si-Mohamed, Salim; Bar-Ness, Daniel; Sigovan, Monica; Cormode, David P.; Coulon, Philippe; Coche, Emmanuel; Vlassenbroek, Alain; Normand, Gabrielle; Boussel, Loic; Douek, Philippe

    2017-11-01

    Spectral photon-counting CT (SPCCT) is an emerging X-ray imaging technology that extends the scope of available diagnostic imaging tools. The main advantage of photon-counting CT technology is better sampling of the spectral information from the transmitted spectrum in order to benefit from additional physical information being produced during matter interaction, including photo-electric and Compton effects, and the K-edge effect. The K-edge, which is specific for a given element, is the increase in X-ray absorption of the element above the binding energy between its inner electronic shell and the nucleus. Hence, the spectral information contributes to better characterization of tissues and materials of interest, explaining the excitement surrounding this area of X-ray imaging. Other improvements of SPCCT compared with conventional CT, such as higher spatial resolution, lower radiation exposure and lower noise are also expected to provide benefits for diagnostic imaging. In this review, we describe multi-energy CT imaging, from dual energy to photon counting technology, and our initial experience results using a clinical-scale spectral photon counting CT (SPCCT) prototype system in vitro and in vivo. In addition, possible clinical applications are introduced.

  17. Reanimating patients: cardio-respiratory CT and MR motion phantoms based on clinical CT patient data

    NASA Astrophysics Data System (ADS)

    Mayer, Johannes; Sauppe, Sebastian; Rank, Christopher M.; Sawall, Stefan; Kachelrieß, Marc

    2017-03-01

    Until today several algorithms have been developed that reduce or avoid artifacts caused by cardiac and respiratory motion in computed tomography (CT). The motion information is converted into so-called motion vector fields (MVFs) and used for motion compensation (MoCo) during the image reconstruction. To analyze these algorithms quantitatively there is the need for ground truth patient data displaying realistic motion. We developed a method to generate a digital ground truth displaying realistic cardiac and respiratory motion that can be used as a tool to assess MoCo algorithms. By the use of available MoCo methods we measured the motion in CT scans with high spatial and temporal resolution and transferred the motion information onto patient data with different anatomy or imaging modality, thereby reanimating the patient virtually. In addition to these images the ground truth motion information in the form of MVFs is available and can be used to benchmark the MVF estimation of MoCo algorithms. We here applied the method to generate 20 CT volumes displaying detailed cardiac motion that can be used for cone-beam CT (CBCT) simulations and a set of 8 MR volumes displaying respiratory motion. Our method is able to reanimate patient data virtually. In combination with the MVFs it serves as a digital ground truth and provides an improved framework to assess MoCo algorithms.

  18. A post-reconstruction method to correct cupping artifacts in cone beam breast computed tomography

    PubMed Central

    Altunbas, M. C.; Shaw, C. C.; Chen, L.; Lai, C.; Liu, X.; Han, T.; Wang, T.

    2007-01-01

    In cone beam breast computed tomography (CT), scattered radiation leads to nonuniform biasing of CT numbers known as a cupping artifact. Besides being visual distractions, cupping artifacts appear as background nonuniformities, which impair efficient gray scale windowing and pose a problem in threshold based volume visualization/segmentation. To overcome this problem, we have developed a background nonuniformity correction method specifically designed for cone beam breast CT. With this technique, the cupping artifact is modeled as an additive background signal profile in the reconstructed breast images. Due to the largely circularly symmetric shape of a typical breast, the additive background signal profile was also assumed to be circularly symmetric. The radial variation of the background signals were estimated by measuring the spatial variation of adipose tissue signals in front view breast images. To extract adipose tissue signals in an automated manner, a signal sampling scheme in polar coordinates and a background trend fitting algorithm were implemented. The background fits compared with targeted adipose tissue signal value (constant throughout the breast volume) to get an additive correction value for each tissue voxel. To test the accuracy, we applied the technique to cone beam CT images of mastectomy specimens. After correction, the images demonstrated significantly improved signal uniformity in both front and side view slices. The reduction of both intra-slice and inter-slice variations in adipose tissue CT numbers supported our observations. PMID:17822018

  19. Development of proton computed tomography detectors for applications in hadron therapy

    NASA Astrophysics Data System (ADS)

    Bashkirov, Vladimir A.; Johnson, Robert P.; Sadrozinski, Hartmut F.-W.; Schulte, Reinhard W.

    2016-02-01

    Radiation therapy with protons and heavier ions is an attractive form of cancer treatment that could enhance local control and survival of cancers that are currently difficult to cure and lead to less side effects due to sparing of normal tissues. However, particle therapy faces a significant technical challenge because one cannot accurately predict the particle range in the patient using data provided by existing imaging technologies. Proton computed tomography (pCT) is an emerging imaging modality capable of improving the accuracy of range prediction. In this paper, we describe the successive pCT scanners designed and built by our group with the goal to support particle therapy treatment planning and image guidance by reconstructing an accurate 3D map of the stopping power relative to water in patient tissues. The pCT scanners we have built to date consist of silicon telescopes, which track the proton before and after the object to be reconstructed, and an energy or range detector, which measures the residual energy and/or range of the protons used to evaluate the water equivalent path length (WEPL) of each proton in the object. An overview of a decade-long evolution of the conceptual design of pCT scanners and their calibration is given. Results of scanner performance tests are presented, which demonstrate that the latest pCT scanner approaches readiness for clinical applications in hadron therapy.

  20. Dual-modality, fluorescent, PLGA encapsulated bismuth nanoparticles for molecular and cellular fluorescence imaging and computed tomography.

    PubMed

    Swy, Eric R; Schwartz-Duval, Aaron S; Shuboni, Dorela D; Latourette, Matthew T; Mallet, Christiane L; Parys, Maciej; Cormode, David P; Shapiro, Erik M

    2014-11-07

    Reports of molecular and cellular imaging using computed tomography (CT) are rapidly increasing. Many of these reports use gold nanoparticles. Bismuth has similar CT contrast properties to gold while being approximately 1000-fold less expensive. Herein we report the design, fabrication, characterization, and CT and fluorescence imaging properties of a novel, dual modality, fluorescent, polymer encapsulated bismuth nanoparticle construct for computed tomography and fluorescence imaging. We also report on cellular internalization and preliminary in vitro and in vivo toxicity effects of these constructs. 40 nm bismuth(0) nanocrystals were synthesized and encapsulated within 120 nm Poly(dl-lactic-co-glycolic acid) (PLGA) nanoparticles by oil-in-water emulsion methodologies. Coumarin-6 was co-encapsulated to impart fluorescence. High encapsulation efficiency was achieved ∼70% bismuth w/w. Particles were shown to internalize within cells following incubation in culture. Bismuth nanocrystals and PLGA encapsulated bismuth nanoparticles exhibited >90% and >70% degradation, respectively, within 24 hours in acidic, lysosomal environment mimicking media and both remained nearly 100% stable in cytosolic/extracellular fluid mimicking media. μCT and clinical CT imaging was performed at multiple X-ray tube voltages to measure concentration dependent attenuation rates as well as to establish the ability to detect the nanoparticles in an ex vivo biological sample. Dual fluorescence and CT imaging is demonstrated as well. In vivo toxicity studies in rats revealed neither clinically apparent side effects nor major alterations in serum chemistry and hematology parameters. Calculations on minimal detection requirements for in vivo targeted imaging using these nanoparticles are presented. Indeed, our results indicate that these nanoparticles may serve as a platform for sensitive and specific targeted molecular CT and fluorescence imaging.

  1. Segmentation and tracking of lung nodules via graph-cuts incorporating shape prior and motion from 4D CT.

    PubMed

    Cha, Jungwon; Farhangi, Mohammad Mehdi; Dunlap, Neal; Amini, Amir A

    2018-01-01

    We have developed a robust tool for performing volumetric and temporal analysis of nodules from respiratory gated four-dimensional (4D) CT. The method could prove useful in IMRT of lung cancer. We modified the conventional graph-cuts method by adding an adaptive shape prior as well as motion information within a signed distance function representation to permit more accurate and automated segmentation and tracking of lung nodules in 4D CT data. Active shape models (ASM) with signed distance function were used to capture the shape prior information, preventing unwanted surrounding tissues from becoming part of the segmented object. The optical flow method was used to estimate the local motion and to extend three-dimensional (3D) segmentation to 4D by warping a prior shape model through time. The algorithm has been applied to segmentation of well-circumscribed, vascularized, and juxtapleural lung nodules from respiratory gated CT data. In all cases, 4D segmentation and tracking for five phases of high-resolution CT data took approximately 10 min on a PC workstation with AMD Phenom II and 32 GB of memory. The method was trained based on 500 breath-held 3D CT data from the LIDC data base and was tested on 17 4D lung nodule CT datasets consisting of 85 volumetric frames. The validation tests resulted in an average Dice Similarity Coefficient (DSC) = 0.68 for all test data. An important by-product of the method is quantitative volume measurement from 4D CT from end-inspiration to end-expiration which will also have important diagnostic value. The algorithm performs robust segmentation of lung nodules from 4D CT data. Signed distance ASM provides the shape prior information which based on the iterative graph-cuts framework is adaptively refined to best fit the input data, preventing unwanted surrounding tissue from merging with the segmented object. © 2017 American Association of Physicists in Medicine.

  2. Multimodality image integration for radiotherapy treatment: an easy approach

    NASA Astrophysics Data System (ADS)

    Santos, Andres; Pascau, Javier; Desco, Manuel; Santos, Juan A.; Calvo, Felipe A.; Benito, Carlos; Garcia-Barreno, Rafael

    2001-05-01

    The interest of using combined MR and CT information for radiotherapy planning is well documented. However, many planning workstations do not allow to use MR images, nor import predefined contours. This paper presents a new simple approach for transferring segmentation results from MRI to a CT image that will be used for radiotherapy planning, using the same original CT format. CT and MRI images of the same anatomical area are registered using mutual information (MI) algorithm. Targets and organs at risk are segmented by the physician on the MR image, where their contours are easy to track. A locally developed software running on PC is used for this step, with several facilities for the segmentation process. The result is transferred onto the CT by slightly modifying up and down the original Hounsfield values of some points of the contour. This is enough to visualize the contour on the CT, but does not affect dose calculations. The CT is then stored using the original file format of the radiotherapy planning workstation, where the technician uses the segmented contour to design the correct beam positioning. The described method has been tested in five patients. Simulations and patient results show that the dose distribution is not affected by the small modification of pixels of the CT image, while the segmented structures can be tracked in the radiotherapy planning workstation-using adequate window/level settings. The presence of the physician is not requires at the planning workstation, and he/she can perform the segmentation process using his/her own PC. This new approach makes it possible to take advantage from the anatomical information present on the MRI and to transfer the segmentation to the CT used for planning, even when the planning workstation does not allow to import external contours. The physician can draw the limits of the target and areas at risk off-line, thus separating in time the segmentation and planning tasks and increasing the efficiency.

  3. 18F-Fluorodeoxyglucose PET/CT and dynamic contrast-enhanced MRI as imaging biomarkers in malignant pleural mesothelioma.

    PubMed

    Hall, David O; Hooper, Clare E; Searle, Julie; Darby, Michael; White, Paul; Harvey, John E; Braybrooke, Jeremy P; Maskell, Nick A; Masani, Vidan; Lyburn, Iain D

    2018-02-01

    The purpose of this study was to compare the use of fluorine-18-fluorodeoxyglucose (F-FDG) PET with computed tomography (CT) and dynamic contrast-enhanced (DCE) MRI to predict prognosis and monitor treatment in malignant pleural mesothelioma. F-FDG PET/CT and DCE-MRI studies carried out as part of the South West Area Mesothelioma Pemetrexed trial were used. F-FDG PET/CT and DCE-MRI studies were carried out before treatment, and after two cycles of chemotherapy, on patients treated with pemetrexed and cisplatin. A total of 73 patients were recruited, of whom 65 had PET/CT and DCE-MRI scans. Baseline measurements from F-FDG PET/CT (maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis) and DCE-MRI (integrated area under the first 90s of the curve and washout slope) were compared with overall survival (OS) using Kaplan-Meier and Cox regression analyses, and changes in imaging measurements were compared with disease progression. PET/CT and DCE-MRI measurements were not correlated with each other. Maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis were significantly related to OS with Cox regression analysis and Kaplan-Meir analysis, and DCE-MRI washout curve shape was significantly related to OS. DCE-MRI curve shape can be combined with F-FDG PET/CT to give additional prognostic information. Changes in measurements were not related to progression-free survival. F-FDG PET/CT and DCE-MRI give prognostic information in malignant pleural mesothelioma. Neither PET/CT nor DCE-MRI is useful for monitoring disease progression.

  4. Personalized Guideline-Based Treatment Recommendations Using Natural Language Processing Techniques.

    PubMed

    Becker, Matthias; Böckmann, Britta

    2017-01-01

    Clinical guidelines and clinical pathways are accepted and proven instruments for quality assurance and process optimization. Today, electronic representation of clinical guidelines exists as unstructured text, but is not well-integrated with patient-specific information from electronic health records. Consequently, generic content of the clinical guidelines is accessible, but it is not possible to visualize the position of the patient on the clinical pathway, decision support cannot be provided by personalized guidelines for the next treatment step. The Systematized Nomenclature of Medicine - Clinical Terms (SNOMED CT) provides common reference terminology as well as the semantic link for combining the pathways and the patient-specific information. This paper proposes a model-based approach to support the development of guideline-compliant pathways combined with patient-specific structured and unstructured information using SNOMED CT. To identify SNOMED CT concepts, a software was developed to extract SNOMED CT codes out of structured and unstructured German data to map these with clinical pathways annotated in accordance with the systematized nomenclature.

  5. A Comparison of Several Artificial Neural Network Classifiers for CT Images of Hardwood Logs

    Treesearch

    Daniel L. Schmoldt; Jing He; A. Lynn Abbott

    1998-01-01

    Knowledge of internal log defects, obtained by scanning, is critical to efficiency improvements for future hardwood sawmills. Nevertheless, before computed tomography (CT) scanning can be applied in industrial operations, we need to automatically interpret scan information so that it can provide the saw operator with the information necessary to make proper sawing...

  6. A review of cognitive therapy in acute medical settings. Part I: therapy model and assessment.

    PubMed

    Levin, Tomer T; White, Craig A; Kissane, David W

    2013-04-01

    Although cognitive therapy (CT) has established outpatient utility, there is no integrative framework for using CT in acute medical settings where most psychosomatic medicine (P-M) clinicians practice. Biopsychosocial complexity challenges P-M clinicians who want to use CT as the a priori psychotherapeutic modality. For example, how should clinicians modify the data gathering and formulation process to support CT in acute settings? Narrative review methodology is used to describe the framework for a CT informed interview, formulation, and assessment in acute medical settings. Because this review is aimed largely at P-M trainees and educators, exemplary dialogues model the approach (specific CT strategies for common P-M scenarios appear in the companion article.) Structured data gathering needs to be tailored by focusing on cognitive processes informed by the cognitive hypothesis. Agenda setting, Socratic questioning, and adaptations to the mental state examination are necessary. Specific attention is paid to the CT formulation, Folkman's Cognitive Coping Model, self-report measures, data-driven evaluations, and collaboration (e.g., sharing the formulation with the patient.) Integrative CT-psychopharmacological approaches and the importance of empathy are emphasized. The value of implementing psychotherapy in parallel with data gathering because of time urgency is advocated, but this is a significant departure from usual outpatient approaches in which psychotherapy follows evaluation. This conceptual approach offers a novel integrative framework for using CT in acute medical settings, but future challenges include demonstrating clinical outcomes and training P-M clinicians so as to demonstrate fidelity.

  7. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion.

    PubMed

    Yang, Y X; Teo, S-K; Van Reeth, E; Tan, C H; Tham, I W K; Poh, C L

    2015-08-01

    Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors' proposed approach. A novel hybrid approach based on deformable image registration (DIR) and finite element method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error <2 mm) were achieved using the authors' proposed approach. Their hybrid approach achieved a 40% error reduction (based on landmarks assessment) over using only DIR techniques. The synthetic 4D-CT dataset generated has high spatial resolution, has excellent lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.

  8. Comparative investigation of body composition in male dogs using CT and body fat analysis software.

    PubMed

    Kobayashi, Toyokazu; Koie, Hiroshi; Kusumi, Akiko; Kitagawa, Masato; Kanayama, Kiichi; Otsuji, Kazuya

    2014-03-01

    In small animal veterinary practices, body condition score (BCS) is generally used to diagnose obesity. However, BCS does not constitute objective data. In this study, we investigated the value of using human body fat analysis software for male dogs. We also compared changes in body fat after neutering. Changes in body fat at the time of neutering (age 1 year) and 1 year later were compared by performing CT scanning and using human body fat analysis software. We found that body fat increased in all the individuals tested. In terms of the site of fat accumulation, subcutaneous fat was more pronounced than visceral fat with a marked increase on the dorsal side of the abdomen rather than the thorax.

  9. Investigation of Carbon Fiber Architecture in Braided Composites Using X-Ray CT Inspection

    NASA Technical Reports Server (NTRS)

    Rhoads, Daniel J.; Miller, Sandi G.; Roberts, Gary D.; Rauser, Richard W.; Golovaty, Dmitry; Wilber, J. Patrick; Espanol, Malena I.

    2017-01-01

    During the fabrication of braided carbon fiber composite materials, process variations occur which affect the fiber architecture. Quantitative measurements of local and global fiber architecture variations are needed to determine the potential effect of process variations on mechanical properties of the cured composite. Although non-destructive inspection via X-ray CT imaging is a promising approach, difficulties in quantitative analysis of the data arise due to the similar densities of the material constituents. In an effort to gain more quantitative information about features related to fiber architecture, methods have been explored to improve the details that can be captured by X-ray CT imaging. Metal-coated fibers and thin veils are used as inserts to extract detailed information about fiber orientations and inter-ply behavior from X-ray CT images.

  10. Diagnostic Imaging of the Hepatobiliary System: An Update.

    PubMed

    Marolf, Angela J

    2017-05-01

    Recent advances in diagnostic imaging of the hepatobiliary system include MRI, computed tomography (CT), contrast-enhanced ultrasound, and ultrasound elastography. With the advent of multislice CT scanners, sedated examinations in veterinary patients are feasible, increasing the utility of this imaging modality. CT and MRI provide additional information for dogs and cats with hepatobiliary diseases due to lack of superimposition of structures, operator dependence, and through intravenous contrast administration. Advanced ultrasound methods can offer complementary information to standard ultrasound imaging. These newer imaging modalities assist clinicians by aiding diagnosis, prognostication, and surgical planning. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Radiological protection in computed tomography and cone beam computed tomography.

    PubMed

    Rehani, M M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. Imaging of the thyroid in benign and malignant disease.

    PubMed

    Intenzo, Charles M; Dam, Hung Q; Manzone, Timothy A; Kim, Sung M

    2012-01-01

    The thyroid gland was one of the first organs imaged in nuclear medicine, beginning in the 1940s. Thyroid scintigraphy is based on a specific phase or prelude to thyroid hormone synthesis, namely trapping of iodide or iodide analogues (ie, Tc99m pertechnetate), and in the case of radioactive iodine, eventual incorporation into thyroid hormone synthesis within the thyroid follicle. Moreover, thyroid scintigraphy is a reflection of the functional state of the gland, as well as the physiological state of any structure (ie, nodule) within the gland. Scintigraphy, therefore, provides information that anatomical imaging (ie, ultrasound, computed tomography [CT], magnetic resonance imaging) lacks. Thyroid scintigraphy plays an essential role in the management of patients with benign or malignant thyroid disease. In the former, the structure or architecture of the gland is best demonstrated by anatomical or cross-sectional imaging, such as ultrasound, CT, or even magnetic resonance imaging. The role of scintigraphy, however, is to display the functional state of the thyroid gland or that of a clinically palpable nodule within the gland. Such information is most useful in (1) patients with thyrotoxicosis, and (2) those patients whose thyroid nodules would not require tissue sampling if their nodules are hyperfunctioning. In neoplastic thyroid disease, thyroid scintigraphy is often standard of care for postthyroidectomy remnant evaluation and in subsequent thyroid cancer surveillance. Planar radioiodine imaging, in the form of the whole-body scan (WBS) and posttherapy scan (PTS), is a fundamental tool in differentiated thyroid cancer management. Continued controversy remains over the utility of WBS in a variety of patient risk groups and clinical scenarios. Proponents on both sides of the arguments compare WBS with PTS, thyroglobulin, and other imaging modalities with differing results. The paucity of large, randomized, prospective studies results in dependence on consensus expert opinion and retrospective analysis with inherent bias. With a growing trend not to ablate low-risk patients, so that a PTS cannot be performed, some thyroid carcinoma patients may never have radioiodine imaging. In routine clinical practice, however, imaging plays a critical role in patient management both before and after treatment. Moreover, as evidenced by the robust flow of publications concerning WBS and PTS, planar imaging of thyroid carcinoma remains a topic of great interest in this modern age of rapidly advancing cross sectional and hybrid imaging with single-photon emission computed tomography, single-photon emission computed tomography/CT, and positron emission tomography/CT. Copyright © 2012. Published by Elsevier Inc.

  13. Deformable image registration for multimodal lung-cancer staging

    NASA Astrophysics Data System (ADS)

    Cheirsilp, Ronnarit; Zang, Xiaonan; Bascom, Rebecca; Allen, Thomas W.; Mahraj, Rickhesvar P. M.; Higgins, William E.

    2016-03-01

    Positron emission tomography (PET) and X-ray computed tomography (CT) serve as major diagnostic imaging modalities in the lung-cancer staging process. Modern scanners provide co-registered whole-body PET/CT studies, collected while the patient breathes freely, and high-resolution chest CT scans, collected under a brief patient breath hold. Unfortunately, no method exists for registering a PET/CT study into the space of a high-resolution chest CT scan. If this could be done, vital diagnostic information offered by the PET/CT study could be brought seamlessly into the procedure plan used during live cancer-staging bronchoscopy. We propose a method for the deformable registration of whole-body PET/CT data into the space of a high-resolution chest CT study. We then demonstrate its potential for procedure planning and subsequent use in multimodal image-guided bronchoscopy.

  14. Radiotherapy volume delineation using 18F-FDG-PET/CT modifies gross node volume in patients with oesophageal cancer.

    PubMed

    Jimenez-Jimenez, E; Mateos, P; Aymar, N; Roncero, R; Ortiz, I; Gimenez, M; Pardo, J; Salinas, J; Sabater, S

    2018-05-02

    Evidence supporting the use of 18F-FDG-PET/CT in the segmentation process of oesophageal cancer for radiotherapy planning is limited. Our aim was to compare the volumes and tumour lengths defined by fused PET/CT vs. CT simulation. Twenty-nine patients were analyzed. All patients underwent a single PET/CT simulation scan. Two separate GTVs were defined: one based on CT data alone and another based on fused PET/CT data. Volume sizes for both data sets were compared and the spatial overlap was assessed by the Dice similarity coefficient (DSC). The gross tumour volume (GTVtumour) and maximum tumour diameter were greater by PET/CT, and length of primary tumour was greater by CT, but differences were not statistically significant. However, the gross node volume (GTVnode) was significantly greater by PET/CT. The DSC analysis showed excellent agreement for GTVtumour, 0.72, but was very low for GTVnode, 0.25. Our study shows that the volume definition by PET/CT and CT data differs. CT simulation, without taking into account PET/CT information, might leave cancer-involved nodes out of the radiotherapy-delineated volumes.

  15. [Application of computed tomography (CT) examination for forensic medicine].

    PubMed

    Urbanik, Andrzej; Chrzan, Robert

    2013-01-01

    The aim of the study is to present a own experiences in usage of post mortem CT examination for forensic medicine. With the help of 16-slice CT scanner 181 corpses were examined. Obtained during acquisition imaging data are later developed with dedicated programmes. Analyzed images were extracted from axial sections, multiplanar reconstructions as well as 3D reconstructions. Gained information helped greatly when classical autopsy was performed by making it more accurate. A CT scan images recorded digitally enable to evaluate corpses at any time, despite processes of putrefaction or cremation. If possible CT examination should precede classical autopsy.

  16. Computed tomography scan diagnosis of occult groin hernia.

    PubMed

    Garvey, J F W

    2012-06-01

    The value of computed tomography (CT) for the diagnosis of clinically occult (hidden) groin hernia was assessed in a series of patients presenting with undiagnosed groin pain. A total of 158 consecutive patients presenting over a period of 5 years with undiagnosed groin pain or lower abdominal pain and negative or equivocal clinical findings were radiologically assessed with non-contrast CT. The decision to manage operatively or conservatively was then based on a combination of the clinical and CT findings. Outcomes were assessed at 10 years follow-up. The study cohort comprised 158 patients presenting with groin or lower abdominal pain and/or swelling, and was studied prospectively. Seven of these patients were re-investigated at a later date after developing new pain on either the ipsilateral or contralateral side, giving a total of 165 CT examinations. One-third of cases (54) had clinically occult groin hernias and most of the remaining cases had diagnoses that could be managed non-operatively. Of those who came to surgery, the pre-operative CT diagnosis of hernia had a positive predictive value (PPV) of 92% and a negative predictive value (NPV) of 96% (overall accuracy 94%). Lipoma of the spermatic cord was responsible for three of five false-positive CT results. The concept of sports hernia/groin disruption injury (GDI) was encountered, and this entity is discussed in this paper. In the group of patients without hernia findings on CT, the most common diagnoses were rectus abdominis and/or pyramidalis muscle injury which could be treated by physiotherapy (22%), GDI (16%), post-surgical problems (14%), miscellaneous (20%) and 'no abnormality' was identified in 15%. Overall, there were 111 patients with a 'non-hernia' CT diagnosis, of which urological, gynaecological, gastrointestinal and neuralgia contributed to the non-musculoskeletal diagnosis. This prospective non-contrast CT study of patients with undiagnosed chronic groin pain detected the majority of occult hernias requiring surgical intervention. These results suggest that CT can be a useful adjunct to the evaluation of patients presenting with chronic undiagnosed groin pain, but that experienced clinical judgment remains a critical element in the diagnostic pathway.

  17. Churg–Strauss syndrome in a patient previously diagnosed with multiple sclerosis

    PubMed Central

    Sarkar, Pamela; Ibitoye, Richard Tolulope; Promnitz, Douglas Anthony

    2011-01-01

    A lady in her 70s with a background of multiple sclerosis (MS) and late-onset asthma was admitted with a 2-week history of cough and shortness of breath, progressive right-sided weakness and functional decline. Investigation revealed eosinophilia, elevated myeloperoxidase antineutrophil cytoplasmic antibody, CT sinuses showed long-standing inflammatory changes consistent with sinonasal polyposis and MRI head showed lesions consistent with vasculitis. She then developed left-sided weakness and increased wheeze. Review of her case notes demonstrated that, the eosinophilia was long-standing, her asthma was severe and steroid-dependent, and her neurologic syndrome was atypical for MS. Intravenous methylprednisolone then cyclophosphamide were administered. She demonstrated remarkable improvement, becoming more alert, with improvement in left-sided weakness. A diagnosis of Churg–Strauss syndrome was established. She was discharged to a nursing home with outpatient rheumatology follow-up. The diagnosis of MS was revisited. PMID:22679315

  18. A Corticothalamic Circuit for Refining Tactile Encoding.

    PubMed

    Pauzin, François Philippe; Krieger, Patrik

    2018-05-01

    A fundamental task for the brain is to determine which aspects of the continuous flow of information is the most relevant in a given behavioral situation. The information flow is regulated via dynamic interactions between feedforward and feedback pathways. One such pathway is via corticothalamic feedback. Layer 6 (L6) corticothalamic (CT) cells make both cortical and thalamic connections and, therefore, are key modulators of activity in both areas. The functional properties of L6 CT cells in sensory processing were investigated in the mouse whisker system. Optogenetic activation of L6 CT neurons decreased spontaneous spiking, with the net effect that a whisker-evoked response was more accurately detected (larger evoked-to-spontaneous spiking ratio) but at the expense of reducing the response probability. In addition, L6 CT activation decreases sensory adaptation in both the thalamus and cortex. L6 CT activity can thus tune the tactile system, depending on the behaviorally relevant tactile input. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Separation of left and right lungs using 3D information of sequential CT images and a guided dynamic programming algorithm

    PubMed Central

    Park, Sang Cheol; Leader, Joseph Ken; Tan, Jun; Lee, Guee Sang; Kim, Soo Hyung; Na, In Seop; Zheng, Bin

    2011-01-01

    Objective this article presents a new computerized scheme that aims to accurately and robustly separate left and right lungs on CT examinations. Methods we developed and tested a method to separate the left and right lungs using sequential CT information and a guided dynamic programming algorithm using adaptively and automatically selected start point and end point with especially severe and multiple connections. Results the scheme successfully identified and separated all 827 connections on the total 4034 CT images in an independent testing dataset of CT examinations. The proposed scheme separated multiple connections regardless of their locations, and the guided dynamic programming algorithm reduced the computation time to approximately 4.6% in comparison with the traditional dynamic programming and avoided the permeation of the separation boundary into normal lung tissue. Conclusions The proposed method is able to robustly and accurately disconnect all connections between left and right lungs and the guided dynamic programming algorithm is able to remove redundant processing. PMID:21412104

  20. [Exploration of the Care Needs of Post-Chemotherapy Lung Cancer Patients and Related Factors].

    PubMed

    Chiu, Hui-Ying; Lin, Yu-Hua; Wang, Chin-Chou; Chen, Wan-Yi; Chang, Huang-Chih; Lin, Meng-Chih

    2016-06-01

    Chemotherapy (CT) is the first priority treatment for advanced stage lung cancer. However, symptom distress, impaired ability to conduct daily activities, and post-CT care needs are potential side effects of CT. To explore the factors related to the care needs of post-chemotherapy lung cancer patients. A cross-sectional study was used. One hundred and twenty-one adult patients who had been diagnosed with advanced-stage lung cancer and who had undergone CT using the Platinum and Docetaxel doublet regimen were recruited from a medical center in southern Taiwan. The instruments used included a nursing care needs survey, symptoms distress scale, daily activity interference scale, and patient characteristics datasheet. Participants self-prioritized their emergency management, health consultation, and emotional support activities based on their perceived care needs. The top three post-CT symptoms in terms of severity were: fatigue, appetite change, and sleep disorder. Primary disruptions in daily activities during the post-CT period related to: holding social activities, work, and stair climbing. Significant and positive correlations were found among daily activity interference (r = .30, p < .01), symptoms distress (r = .23, p < .01), and care needs. The regression model indicated daily activity interference as a predictor of care needs, accounting for 10.7% of the total variance. These results highlight the relationships among care needs, symptom distress, and daily activity interference in post-chemotherapy lung-cancer patients. The present study provides a reference for nursing care to reduce the symptom distress, to enhance the performance of daily activities, and to meet the care needs of lung-cancer patients.

  1. Radiation exposure of the radiologist's eye lens during CT-guided interventions.

    PubMed

    Heusch, Philipp; Kröpil, Patric; Buchbender, Christian; Aissa, Joel; Lanzman, Rotem S; Heusner, Till A; Ewen, Klaus; Antoch, Gerald; Fürst, Günther

    2014-02-01

    In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.

  2. Choroidal Haller's and Sattler's Layers Thickness in Normal Indian Eyes.

    PubMed

    Roy, Rupak; Saurabh, Kumar; Vyas, Chinmayi; Deshmukh, Kaustubh; Sharma, Preeti; Chandrasekharan, Dhileesh P; Bansal, Aditya

    2018-01-01

    This study aims to study normative choroidal thickness (CT) and Haller's and Sattler's layers thickness in normal Indian eyes. The choroidal imaging of 73 eyes of 43 healthy Indian individuals was done using enhanced depth imaging feature of spectralis optical coherence tomography. Rraster scan protocol centered at fovea was used for imaging separately by two observers. CT was defined as the length of the perpendicular line drown from the outer border of hypereflective RPE-Bruch's complex to inner margin of choroidoscleral junction. Choroidal vessel layer thickness was measured after defining a largest choroidal vessel lumen within 750 μ on either side of the subfoveal CT vector. A perpendicular line was drawn to the innermost border of this lumen, and the distance between the perpendicular line and innermost border of choroidoscleral junction gave large choroidal vessel layer thickness (LCVLT, Haller's layer). Medium choroidal vessel layer thickness (MCVLT, Sattler's layer) was measured as the distance between same perpendicular line and outer border of hypereflective RPE-Bruch's complex. The mean age of individuals was 28.23 ± 15.29 years (range 14-59 years). Overall, the mean subfoveal CT was 331.6 ± 63.9 μ. Mean LCVLT was 227.08 ± 51.24 μ and the mean MCVLT was 95.65 ± 23.62 μ. CT was maximum subfoveally with gradual reduction in the thickness as the distance from the fovea increased. This is the first study describing the choroidal sublayer thickness, i.e., Haller's and Sattler's layer thickness along with CT in healthy Indian population.

  3. Choroidal Haller's and Sattler's Layers Thickness in Normal Indian Eyes

    PubMed Central

    Roy, Rupak; Saurabh, Kumar; Vyas, Chinmayi; Deshmukh, Kaustubh; Sharma, Preeti; Chandrasekharan, Dhileesh P.; Bansal, Aditya

    2018-01-01

    AIM: This study aims to study normative choroidal thickness (CT) and Haller's and Sattler's layers thickness in normal Indian eyes. MATERIALS AND METHODS: The choroidal imaging of 73 eyes of 43 healthy Indian individuals was done using enhanced depth imaging feature of spectralis optical coherence tomography. Rraster scan protocol centered at fovea was used for imaging separately by two observers. CT was defined as the length of the perpendicular line drown from the outer border of hypereflective RPE-Bruch's complex to inner margin of choroidoscleral junction. Choroidal vessel layer thickness was measured after defining a largest choroidal vessel lumen within 750 μ on either side of the subfoveal CT vector. A perpendicular line was drawn to the innermost border of this lumen, and the distance between the perpendicular line and innermost border of choroidoscleral junction gave large choroidal vessel layer thickness (LCVLT, Haller's layer). Medium choroidal vessel layer thickness (MCVLT, Sattler's layer) was measured as the distance between same perpendicular line and outer border of hypereflective RPE-Bruch's complex. RESULTS: The mean age of individuals was 28.23 ± 15.29 years (range 14–59 years). Overall, the mean subfoveal CT was 331.6 ± 63.9 μ. Mean LCVLT was 227.08 ± 51.24 μ and the mean MCVLT was 95.65 ± 23.62 μ. CT was maximum subfoveally with gradual reduction in the thickness as the distance from the fovea increased. CONCLUSION: This is the first study describing the choroidal sublayer thickness, i.e., Haller's and Sattler's layer thickness along with CT in healthy Indian population. PMID:29899646

  4. CT dose modulation using automatic exposure control in whole-body PET/CT: effects of scout imaging direction and arm positioning.

    PubMed

    Inoue, Yusuke; Nagahara, Kazunori; Kudo, Hiroko; Itoh, Hiroyasu

    2018-01-01

    Automatic exposure control (AEC) modulates tube current and consequently X-ray exposure in CT. We investigated the behavior of AEC systems in whole-body PET/CT. CT images of a whole-body phantom were acquired using AEC on two scanners from different manufactures. The effects of scout imaging direction and arm positioning on dose modulation were evaluated. Image noise was assessed in the chest and upper abdomen. On one scanner, AEC using two scout images in the posteroanterior (PA) and lateral (Lat) directions provided relatively constant image noise along the z-axis with the arms at the sides. Raising the arms increased tube current in the head and neck and decreased it in the body trunk. Image noise increased in the upper abdomen, suggesting excessive reduction in radiation exposure. AEC using the PA scout alone strikingly increased tube current and reduced image noise in the shoulder. Raising the arms did not substantially influence dose modulation and decreased noise in the abdomen. On the other scanner, AEC using the PA scout alone or Lat scout alone resulted in similar dose modulation. Raising the arms increased tube current in the head and neck and decreased it in the trunk. Image noise was higher in the upper abdomen than in the middle and lower chest, and was not influenced by arm positioning. CT dose modulation using AEC may vary greatly depending on scout direction. Raising the arms tended to decrease radiation exposure; however, the effect depends on scout direction and the AEC system.

  5. A digital model individual template and CT-guided 125I seed implants for malignant tumors of the head and neck.

    PubMed

    Huang, Ming-Wei; Liu, Shu-Ming; Zheng, Lei; Shi, Yan; Zhang, Jie; Li, Yan-Sheng; Yu, Guang-Yan; Zhang, Jian-Guo

    2012-11-01

    To enhance the accuracy of radioactive seed implants in the head and neck, a digital model individual template, containing information simultaneously on needle pathway and facial features, was designed to guide implantation with CT imaging. Thirty-one patients with recurrent and local advanced malignant tumors of head and neck after prior surgery and radiotherapy were involved in this study. Before (125)I implants, patients received CT scans based on 0.75mm thickness. And the brachytherapy treatment planning system (BTPS) software was used to make the implantation plan based on the CT images. Mimics software and Geomagic software were used to read the data containing CT images and implantation plan, and to design the individual template. Then the individual template containing the information of needle pathway and face features simultaneously was made through rapid prototyping (RP) technique. All patients received (125)I seeds interstitial implantation under the guide of the individual template and CT. The individual templates were positioned easily and accurately, and were stable. After implants, treatment quality evaluation was made by CT and TPS. The seeds and dosages distribution (D(90),V(100),V(150)) were well meet the treatment requirement. Clinical practice confirms that this approach can facilitate easier and more accurate implantation.

  6. 2D-3D registration using gradient-based MI for image guided surgery systems

    NASA Astrophysics Data System (ADS)

    Yim, Yeny; Chen, Xuanyi; Wakid, Mike; Bielamowicz, Steve; Hahn, James

    2011-03-01

    Registration of preoperative CT data to intra-operative video images is necessary not only to compare the outcome of the vocal fold after surgery with the preplanned shape but also to provide the image guidance for fusion of all imaging modalities. We propose a 2D-3D registration method using gradient-based mutual information. The 3D CT scan is aligned to 2D endoscopic images by finding the corresponding viewpoint between the real camera for endoscopic images and the virtual camera for CT scans. Even though mutual information has been successfully used to register different imaging modalities, it is difficult to robustly register the CT rendered image to the endoscopic image due to varying light patterns and shape of the vocal fold. The proposed method calculates the mutual information in the gradient images as well as original images, assigning more weight to the high gradient regions. The proposed method can emphasize the effect of vocal fold and allow a robust matching regardless of the surface illumination. To find the viewpoint with maximum mutual information, a downhill simplex method is applied in a conditional multi-resolution scheme which leads to a less-sensitive result to local maxima. To validate the registration accuracy, we evaluated the sensitivity to initial viewpoint of preoperative CT. Experimental results showed that gradient-based mutual information provided robust matching not only for two identical images with different viewpoints but also for different images acquired before and after surgery. The results also showed that conditional multi-resolution scheme led to a more accurate registration than single-resolution.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abboud, Georges, E-mail: drgeorgesabboud@hotmail.com; Midulla, Marco, E-mail: marcomidu@gmail.com; Lions, Christophe, E-mail: c-lions@chru-lille.fr

    The May-Thurner syndrome is a well-known anatomical anomaly where the left common iliac vein (LCIV) is compressed between the right common iliac artery and the fifth vertebral body. This report describes the case of a 'right-sided' May-Thurner syndrome where the right common iliac vein (RCIV) is compressed by the left common iliac artery in a patient with a left-sided inferior vena cava (IVC). A 26-year-old woman was admitted to our institution with acute edema of the right lower limb. The diagnosis of May-Thurner syndrome was done by CT scan and confirmed by phlebography. An endovascular treatment with stenting was carriedmore » out, with good patency and clinical result at 12-month follow-up.« less

  8. Right massive haemothorax as the presentation of blunt cardiac rupture: the pitfall of coexisting pericardial laceration

    PubMed Central

    Chen, Shao-Wei; Huang, Yao-Kuang; Liao, Chien-Hung; Wang, Shang-Yu

    2014-01-01

    A 74-year old female was transferred to our institution because of blunt chest trauma. Chest X-ray and computed tomography (CT) revealed right haemothorax and little pericardial effusion. She was taken to the operating theatre for emergent operation because of hypotension and massive bleeding from the right-sided chest tube. Cardiopulmonary resuscitation was started during surgical exploration. There were three 1-cm lacerations actively bleeding from the right atrium and inferior vena cava junction, which were repaired successfully. Furthermore, we identified a 10 cm laceration in the right-side pleuropericardium and a communication existing between the pericardial space and the right pleural space. PMID:24218497

  9. Right massive haemothorax as the presentation of blunt cardiac rupture: the pitfall of coexisting pericardial laceration.

    PubMed

    Chen, Shao-Wei; Huang, Yao-Kuang; Liao, Chien-Hung; Wang, Shang-Yu

    2014-02-01

    A 74-year old female was transferred to our institution because of blunt chest trauma. Chest X-ray and computed tomography (CT) revealed right haemothorax and little pericardial effusion. She was taken to the operating theatre for emergent operation because of hypotension and massive bleeding from the right-sided chest tube. Cardiopulmonary resuscitation was started during surgical exploration. There were three 1-cm lacerations actively bleeding from the right atrium and inferior vena cava junction, which were repaired successfully. Furthermore, we identified a 10 cm laceration in the right-side pleuropericardium and a communication existing between the pericardial space and the right pleural space.

  10. View southwest along Brown Road showing residential and commercial buildings ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View southwest along Brown Road showing residential and commercial buildings on the north and south sides of the road - Brooklyn Green, North Green, South Green, & West Green, parts of Brown Road, Canterbury Road (Route 169), Hartford Road (Route 6), Hyde Road, Pomfret Road (Route 169), Prince Hill Road, Providence Road (Route 6), Wauregan Road (Routes 169 & 205), & Wolf Den Road, Brooklyn, Windham County, CT

  11. 18. Electrically driven pumps in Armory Street Pump House. Pumps ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Electrically driven pumps in Armory Street Pump House. Pumps in background formerly drew water from the clear well. They went out of service when use of the beds was discontinued. Pumps in the foreground provide high pressure water to Hamden. - Lake Whitney Water Filtration Plant, Armory Street Pumphouse, North side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  12. 53. Photocopy of photograph (original negative is property of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    53. Photocopy of photograph (original negative is property of the Central Connecticut Regional Water Authority and preserved in their archives at 90 Sargent Drive, New Haven, Connecticut 06511-5966), photographer unknown, circa 1960. View of Whitney Water Filtration Plant Laboratory. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  13. 50. Photocopy of photograph (original negative is property of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. Photocopy of photograph (original negative is property of the Central Connecticut Regional Water Authority and preserved in their archives at 90 Sargent Drive, New Haven, Connecticut 06511-5966), photographer unknown, circa 1959. The sand washer designed by New Haven Water Company. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  14. 49. Photocopy of photograph (original negative is property of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    49. Photocopy of photograph (original negative is property of the Central Connecticut Regional Water Authority and preserved in their archives at 90 Sargent Drive, New Haven, Connecticut 06511-5966), photographer unknown, circa 1935. Sand cleaning at the Whitney Filtration Plant. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  15. [Impact of multi-layer spiral CT angiography of bronchial artery and pulmonary artery in assessment of the main blood supply to the primary lung cancer].

    PubMed

    Xiao, Xiang-sheng; Yu, Hong; Li, Hui-min; Liu, Shi-yuan; Li, Cheng-zhou; Liu, Jing

    2006-04-01

    To investigate the blood supply of primary lung cancer (PLC) using CT angiography for bronchial artery (BA) and pulmonary artery (PA). Thin-section enhanced multi-layer spiral CT (MSCT) were carried out in 147 primary lung cancer patients and 46 healthy subjects as control. Three-dimensional images of bronchial artery and pulmonary artery were obtained using volume render (VR) and multi-planar reconstruction (MPR) or maximum intensity projection (MIP) at the workstation, and their morphological findings and relationship with the mass were assessed. 136 primary lung cancer patients and 32 healthy controls were evaluated for at least one bronchial artery displayed clearly in VR. The detective rate of the bronchial artery was 92.5% and 69.6%, respectively. The bronchial artery caliber and the total section area of lesion side in lung cancer patients were significantly larger than that on the contralateral side and that of the control (P < 0.05). Bronchial artery on the lesion side in lung cancer was dilated and tortuous, directly penetrating into the mass with reticularly anastomosed branches. In the PLC patients, all PA were shown clearly with normal morphological image though crossing over the masses in 54 patients; In 25 PLC patients, the PA being essentially intact, was pushed around and surrounded the mass, giving the "hold ball" sign; In 40 other PLC patients, PA being also intact, the mass surrounded and buried the PA from the outside, crushing the PA flat resulting in an eccentric or centrifugal shrinkage, forming the "dead branch" sign; In the rest 28 patients, the PA was surrounded and even compressed, forming the "residual root" sign. Primary lung cancer patient shows dilated bronchial arteries and increased bronchial artery blood flow, whereas pulmonary arteries just pass through the mass or are compressed by the mass. It is further demonstrated that the bronchial artery, instead of the pulmonary artery, is the main vessel of blood supply to the primary lung cancer as shown by MSCT angiography of bronchial artery and pulmonary artery.

  16. [Accelerated partial breast irradiation with image-guided intensity-modulated radiotherapy following breast-conserving surgery - preliminary results of a phase II clinical study].

    PubMed

    Mészáros, Norbert; Major, Tibor; Stelczer, Gábor; Zaka, Zoltán; Mózsa, Emõke; Fodor, János; Polgár, Csaba

    2015-06-01

    The purpose of the study was to implement accelerated partial breast irradiation (APBI) by means of image-guided intensity-modulated radiotherapy (IG-IMRT) following breast-conserving surgery (BCS) for low-risk early invasive breast cancer. Between July 2011 and March 2014, 60 patients with low-risk early invasive (St I-II) breast cancer who underwent BCS were enrolled in our phase II prospective study. Postoperative APBI was given by means of step and shoot IG-IMRT using 4 to 5 fields to a total dose of 36.9 Gy (9×4.1 Gy) using a twice-a-day fractionation. Before each fraction, series of CT images were taken from the region of the target volume using a kV CT on-rail mounted in the treatment room. An image fusion software was used for automatic image registration of the planning and verification CT images. Patient set-up errors were detected in three directions (LAT, LONG, VERT), and inaccuracies were adjusted by automatic movements of the treatment table. Breast cancer related events, acute and late toxicities, and cosmetic results were registered and analysed. At a median follow-up of 24 months (range 12-44) neither locoregional nor distant failure was observed. Grade 1 (G1), G2 erythema, G1 oedema, and G1 and G2 pain occurred in 21 (35%), 2 (3.3%), 23 (38.3%), 6 (10%) and 2 (3.3%) patients, respectively. No G3-4 acute side effects were detected. Among late radiation side effects G1 pigmentation, G1 fibrosis, and G1 fat necrosis occurred in 5 (8.3%), 7 (11.7%), and 2 (3.3%) patients, respectively. No ≥G2 late toxicity was detected. Excellent and good cosmetic outcome was detected in 45 (75%) and 15 (25%) patients. IG-IMRT is a reproducible and feasible technique for the delivery of APBI following conservative surgery for the treatment of low-risk, early-stage invasive breast carcinoma. Preliminary results are promising, early radiation side effects are minimal, and cosmetic results are excellent.

  17. Whole-body CT in polytrauma patients: The effect of arm position on abdominal image quality when using a human phantom

    NASA Astrophysics Data System (ADS)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-06-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  18. Right Site, Wrong Route - Cannulating the Left Internal Jugular Vein.

    PubMed

    Paik, Peter; Arukala, Sanjay K; Sule, Anupam A

    2018-01-09

    Central venous catheters are placed in approximately five million patients annually in the US. The preferred site of insertion is one with fewer risks and easier access. Although the right internal jugular vein is preferred, on occasion, the left internal jugular may have to be accessed. A patient was admitted for septic shock, cerebrovascular accident, and non-ST-segment elevation myocardial infarction. A central venous line was needed for antibiotic and vasopressor administration. Due to trauma from a fall to the right side and previously failed catheterization attempts at the left subclavian and femoral veins, the left internal jugular vein was accessed. On chest radiography for confirmation, the left internal jugular central venous catheter was seen projecting down the left paraspinal region. It did not take the expected course across the midline toward the right and into the superior vena cava (SVC). A review of a computed tomography (CT) scan of the chest with contrast done on a prior admission revealed a duplicated SVC on the left side that had not been reported in the original CT scan interpretation. A left-sided SVC is present in approximately 0.3% to 0.5% of the population, with 90% of these draining into the coronary sinus. During placements of central venous lines and pacemakers, irritation of the coronary sinus may result in hypotension, arrhythmia, myocardial ischemia, or cardiac arrest. A widened mediastinum can be an indication of a duplicated SVC. When attempting a left internal jugular vein central venous catheter placement, it is important to be aware of venous anomalies in order to prevent complications.

  19. Relationship between colon and kidney: a critical point for percutaneous procedures.

    PubMed

    Atar, Murat; Hatipoglu, Namik Kemal; Soylemez, Haluk; Penbegul, Necmettin; Bozkurt, Yasar; Gumus, Hatice; Sancaktutar, Ahmet Ali; Kuday, Suzan; Bodakci, Mehmet Nuri

    2013-04-01

    The aim of this study was to determine the frequency of anatomical variations of the colon associated with the kidney. A retrospective analysis was performed on 1000 consecutive abdominal computed tomography (CT) scans performed between July 2010 and September 2011. A line parallel to the horizontal plane was drawn through the posterior edge of each kidney at three renal levels: upper, middle and lower pole. The bowel between the psoas muscle and the kidney was determined as the interposition of the colon. The amount of perinephric fat was estimated and graded. The total number of patients undergoing CT scans was 1000 (male/female = 510/490). The mean age of patients was 42.2 years. Seventeen patients (1.7%) had retrorenal colon, of which 12 (1.2%) were on the left side, three (0.3%) on the right side and two (0.2%) were bilateral. Of these 17 cases, 11 were found at the lower, two at the middle and four at the upper pole of the kidney. There was grade I perirenal fat tissue in 13 and grade II in four cases. Interposition of the colon was detected in 32 (3.2%) patients, 30 (3%) on the right and two (0.2%) on the left. The grade of perirenal fat tissue in patients with colon interposition was as follows: 25 patients grade I, six patients grade II and one patient grade III. In accessing the lower pole of the kidney, especially on the left side, the risk of colonic injury should be taken into consideration during percutaneous procedures, regardless of the patient's age and gender.

  20. Thoracic cavity definition for 3D PET/CT analysis and visualization.

    PubMed

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W; Higgins, William E

    2015-07-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical details on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage=99.2% and leakage=0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. With "big data" comes big responsibility: outreach to North Carolina Medicaid patients with 10 or more computed tomography scans in 12 months.

    PubMed

    Biola, Holly; Best, Randall M; Lahlou, Rita M; Burke, Lauren M; Dewar, Charles; Jackson, Carlos T; Broder, Joshua; Grey, Linda; Semelka, Richard C; Dobson, Allen

    2014-01-01

    Patients are being exposed to increasing levels of ionizing radiation, much of it from computed tomography (CT) scans. Adults without a cancer diagnosis who received 10 or more CT scans in 2010 were identified from North Carolina Medicaid claims data and were sent a letter in July 2011 informing them of their radiation exposure; those who had undergone 20 or more CT scans in 2010 were also telephoned. The CT scan exposure of these high-exposure patients during the 12 months following these interventions was compared with that of adult Medicaid patients without cancer who had at least 1 CT scan but were not in the intervention population. The average number of CT scans per month for the high-exposure population decreased over time, but most of that reduction occurred 6-9 months before our interventions took place. At about the same time, the number of CT scans per month also decreased in adult Medicaid patients without cancer who had at least 1 CT scan but were not in the intervention population. Our data do not include information about CT scans that may have been performed during times when patients were not covered by Medicaid. Some of our letters may not have been received or understood. Some high-exposure patients were unintentionally excluded from our study because organization of data on Medicaid claims varies by setting of care. Our patient education intervention was not temporally associated with significant decreases in subsequent CT exposure. Effecting behavior change to reduce exposure to ionizing radiation requires more than an educational letter or telephone call.

  2. Thoracic Cavity Definition for 3D PET/CT Analysis and Visualization

    PubMed Central

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.

    2015-01-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical detail on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage = 99.2% and leakage = 0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment. PMID:25957746

  3. Worsening respiratory function in mechanically ventilated intensive care patients: feasibility and value of xenon-enhanced dual energy CT.

    PubMed

    Hoegl, Sandra; Meinel, Felix G; Thieme, Sven F; Johnson, Thorsten R C; Eickelberg, Oliver; Zwissler, Bernhard; Nikolaou, Konstantin

    2013-03-01

    To evaluate the feasibility and incremental diagnostic value of xenon-enhanced dual-energy CT in mechanically ventilated intensive care patients with worsening respiratory function. The study was performed in 13 mechanically ventilated patients with severe pulmonary conditions (acute respiratory distress syndrome (ARDS), n=5; status post lung transplantation, n=5; other, n=3) and declining respiratory function. CT scans were performed using a dual-source CT scanner at an expiratory xenon concentration of 30%. Both ventilation images (Xe-DECT) and standard CT images were reconstructed from a single CT scan. Findings were recorded for Xe-DECT and standard CT images separately. Ventilation defects on xenon images were matched to morphological findings on standard CT images and incremental diagnostic information of xenon ventilation images was recorded if present. Mean xenon consumption was 2.95 l per patient. No adverse events occurred under xenon inhalation. In the visual CT analysis, the Xe-DECT ventilation defects matched with pathologic changes in lung parenchyma seen in the standard CT images in all patients. Xe-DECT provided additional diagnostic findings in 4/13 patients. These included preserved ventilation despite early pneumonia (n=1), more confident discrimination between a large bulla and pneumothorax (n=1), detection of an airway-to-pneumothorax fistula (n=1) and exclusion of a suspected airway-to-mediastinum fistula (n=1). In all 4 patients, the additional findings had a substantial impact on patients' management. Xenon-enhanced DECT is safely feasible and can add relevant diagnostic information in mechanically ventilated intensive care patients with worsening respiratory function. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. State of the art: dual-energy CT of the abdomen.

    PubMed

    Marin, Daniele; Boll, Daniel T; Mileto, Achille; Nelson, Rendon C

    2014-05-01

    Recent technologic advances in computed tomography (CT)--enabling the nearly simultaneous acquisition of clinical images using two different x-ray energy spectra--have sparked renewed interest in dual-energy CT. By interrogating the unique characteristics of different materials at different x-ray energies, dual-energy CT can be used to provide quantitative information about tissue composition, overcoming the limitations of attenuation-based conventional single-energy CT imaging. In the past few years, intensive research efforts have been devoted to exploiting the unique and powerful opportunities of dual-energy CT for a variety of clinical applications. This has led to CT protocol modifications for radiation dose reduction, improved diagnostic performance for detection and characterization of diseases, as well as image quality optimization. In this review, the authors discuss the basic principles, instrumentation and design, examples of current clinical applications in the abdomen and pelvis, and future opportunities of dual-energy CT.

  5. Classification algorithm of lung lobe for lung disease cases based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Matsuhiro, M.; Kawata, Y.; Niki, N.; Nakano, Y.; Mishima, M.; Ohmatsu, H.; Tsuchida, T.; Eguchi, K.; Kaneko, M.; Moriyama, N.

    2011-03-01

    With the development of multi-slice CT technology, to obtain an accurate 3D image of lung field in a short time is possible. To support that, a lot of image processing methods need to be developed. In clinical setting for diagnosis of lung cancer, it is important to study and analyse lung structure. Therefore, classification of lung lobe provides useful information for lung cancer analysis. In this report, we describe algorithm which classify lungs into lung lobes for lung disease cases from multi-slice CT images. The classification algorithm of lung lobes is efficiently carried out using information of lung blood vessel, bronchus, and interlobar fissure. Applying the classification algorithms to multi-slice CT images of 20 normal cases and 5 lung disease cases, we demonstrate the usefulness of the proposed algorithms.

  6. Biopsy of CT-Occult Bone Lesions Using Anatomic Landmarks for CT Guidance.

    PubMed

    Hillen, Travis J; Talbert, Robert J; Friedman, Michael V; Long, Jeremiah R; Jennings, Jack W; Wessell, Daniel E; Baker, Jonathan C

    2017-07-01

    The purpose of this study is to evaluate the histopathologic diagnostic yield, sample size, procedural time, and dose-length product (DLP) for the biopsy of CT-occult lesions found at MRI or PET or both. A retrospective review of our radiology information system for biopsies of CT-occult lesions using CT guidance from January 1, 2010, through December 31, 2014, was performed and compared with a selection of CT-guided biopsies of CT-evident bone lesions during the same period. The data were then evaluated for diagnostic yield of histopathologic diagnosis, procedural time, use of sedation medication, DLP, and size of specimens obtained. A total of 30 CT-occult biopsies met the inclusion criteria. Twenty-seven of those biopsies had results that were concordant with the patient's primary histopathologic diagnosis, imaging findings, and clinical course. In the CT-evident lesion group, concordant histopathologic abnormalities were identified in 27 of 30 patients. There was a statistically significant increase in number of samples obtained for the CT-evident lesions compared with CT-occult lesions. There was no statistically significant difference in total specimen length, DLP, number of CT scans, procedural time, or use of sedation medication between the CT-occult and CT-evident biopsy groups. Biopsy of CT-occult lesions using anatomic landmarks achieves diagnostic yields similar to those for CT-guided biopsy of CT-evident lesions.

  7. Mutual-information-based registration for ultrasound and CT datasets

    NASA Astrophysics Data System (ADS)

    Firle, Evelyn A.; Wesarg, Stefan; Dold, Christian

    2004-05-01

    In many applications for minimal invasive surgery the acquisition of intra-operative medical images is helpful if not absolutely necessary. Especially for Brachytherapy imaging is critically important to the safe delivery of the therapy. Modern computed tomography (CT) and magnetic resonance (MR) scanners allow minimal invasive procedures to be performed under direct imaging guidance. However, conventional scanners do not have real-time imaging capability and are expensive technologies requiring a special facility. Ultrasound (U/S) is a much cheaper and one of the most flexible imaging modalities. It can be moved to the application room as required and the physician sees what is happening as it occurs. Nevertheless it may be easier to interpret these 3D intra-operative U/S images if they are used in combination with less noisier preoperative data such as CT. The purpose of our current investigation is to develop a registration tool for automatically combining pre-operative CT volumes with intra-operatively acquired 3D U/S datasets. The applied alignment procedure is based on the information theoretic approach of maximizing the mutual information of two arbitrary datasets from different modalities. Since the CT datasets include a much bigger field of view we introduced a bounding box to narrow down the region of interest within the CT dataset. We conducted a phantom experiment using a CIRS Model 53 U/S Prostate Training Phantom to evaluate the feasibility and accuracy of the proposed method.

  8. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Y. X.; Van Reeth, E.; Poh, C. L., E-mail: clpoh@ntu.edu.sg

    2015-08-15

    Purpose: Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors’ proposed approach. Methods: A novel hybrid approach based on deformable image registration (DIR) and finite elementmore » method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. Results: The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error <2 mm) were achieved using the authors’ proposed approach. Their hybrid approach achieved a 40% error reduction (based on landmarks assessment) over using only DIR techniques. Conclusions: The synthetic 4D-CT dataset generated has high spatial resolution, has excellent lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.« less

  9. Computed tomography synthesis from magnetic resonance images in the pelvis using multiple random forests and auto-context features

    NASA Astrophysics Data System (ADS)

    Andreasen, Daniel; Edmund, Jens M.; Zografos, Vasileios; Menze, Bjoern H.; Van Leemput, Koen

    2016-03-01

    In radiotherapy treatment planning that is only based on magnetic resonance imaging (MRI), the electron density information usually obtained from computed tomography (CT) must be derived from the MRI by synthesizing a so-called pseudo CT (pCT). This is a non-trivial task since MRI intensities are neither uniquely nor quantitatively related to electron density. Typical approaches involve either a classification or regression model requiring specialized MRI sequences to solve intensity ambiguities, or an atlas-based model necessitating multiple registrations between atlases and subject scans. In this work, we explore a machine learning approach for creating a pCT of the pelvic region from conventional MRI sequences without using atlases. We use a random forest provided with information about local texture, edges and spatial features derived from the MRI. This helps to solve intensity ambiguities. Furthermore, we use the concept of auto-context by sequentially training a number of classification forests to create and improve context features, which are finally used to train a regression forest for pCT prediction. We evaluate the pCT quality in terms of the voxel-wise error and the radiologic accuracy as measured by water-equivalent path lengths. We compare the performance of our method against two baseline pCT strategies, which either set all MRI voxels in the subject equal to the CT value of water, or in addition transfer the bone volume from the real CT. We show an improved performance compared to both baseline pCTs suggesting that our method may be useful for MRI-only radiotherapy.

  10. CT vaginography: a new CT technique for imaging of upper and middle vaginal fistulas.

    PubMed

    Botsikas, Diomidis; Pluchino, Nicola; Kalovidouri, Anastasia; Platon, Alexandra; Montet, Xavier; Dallenbach, Patrick; Poletti, Pierre-Alexandre

    2017-05-01

    Different types of vaginal fistulas is a relatively uncommon condition in the Western world but very frequent in developing countries. In the past, conventional vaginography was the radiological examination of choice for exploring this condition. CT and MRI are now both used for this purpose. Our objective was to test the feasibility and to explore the potential role of a new CT imaging technique implementing vaginal introitus obstruction and opacification of the vagina with iodine contrast agent, to show patency of a fistula. We describe the technical protocol of CT-vaginography as performed in Geneva University Hospitals, including vaginal catheterization with a Foley catheter and obstruction of the introitus by inflating the balloon of the catheter. We also report three cases of patients with suspected vaginal fistula who underwent CT-vaginography. The examinations were technically successful. In one patient, it revealed the presence of fistulous pathways from the vaginal fornix along the bilateral infected surgical prostheses. In a second patient, it showed a fistula between the vagina and the necrotic cavity of a recurrent cervical cancer. In a third patient, it proved the absence of a suspected vaginal fistula. CT-vaginography is a technically feasible CT protocol that provides anatomical and functional information on clinically suspected vaginal fistulas. Advances in knowledge: After the abandon of conventional vaginography in the era of transaxial imaging, the current modalities of imaging vaginal fistulas provide excellent anatomical detail but less functional information concerning the permeability of a vaginal fistulous pathway. We propose the use of CT-vaginography, a technical protocol that we describe in detail.

  11. Performance of hybrid system for fluorescence and micro-computed tomography in synchronous mode

    NASA Astrophysics Data System (ADS)

    Liu, Xin; Zhang, Yi; Liu, Fei; Guo, Xiaolian; Wang, Xin; Bai, Jing

    2010-11-01

    Fluorescence diffuse optical tomography (FDOT) plays an important role in studying physiological and pathological processes of small animals in vivo. The low spatial resolution, however, limits the ability of FDOT in resolving the biodistributions of fluorescent markers. The anatomical information provided by X-ray computed tomography (CT) can be used to improve the image quality of FDOT. However, in most hybrid FDOT/CT systems, the projection data sets of optics and X-ray are acquired sequentially, which increases the acquisition time and bring in the unwanted soft tissue displacement. In this paper, we evaluate the performance of a synchronous FDOT/CT system, which allows for faster and concurrent imaging. Compared with previous FDOT/CT systems, the two subsystems (FDOT and CT) acquire projection images in synchronous mode, so the body position can keep consistent in the same projection data acquired by both subsystems. The experimental results of phantom and in vivo experiments suggest that the reconstruction quality of FDOT can be significantly improved when structural a priori information is utilized to constrain the reconstruction process. On the other hand, the synchronous FDOT/CT system decreases the imaging time.

  12. Single energy micro CT SkyScan 1173 for the characterization of urinary stone

    NASA Astrophysics Data System (ADS)

    Fitri, L. A.; Asyana, V.; Ridwan, T.; Anwary, F.; Soekersi, H.; Latief, F. D. E.; Haryanto, F.

    2016-08-01

    A urinary stone is a solid piece of material produced from crystallization of excreted substances in the urine. Knowledge of the composition of urinary stones is essential to determine the suitable treatment for the patient. The aim of this research was to characterize urinary stones using single energy micro CT SkyScan 1173. Six human urinary stones were scanned in vitro using 80 kV in micro CT SkyScan 1173. The produced projection, images, were reconstructed using NRecon (in-house software from SkyScan). The images of urinary stones were analyzed using CT Analyser (CT An) to obtain information of the internal structure and the Hounsfield Unit (HU) value to determine the information regarding the composition of the urinary stones, respectively. The average HU values from certain region of interests in the same slice were compared with spectral curves of known materials from National Institute of Standards and Technology (NIST). From the analysis, the composition of the six scanned stones were obtained. Two stones are composed of cystine, two are composed of struvite, two other stones are composed of struvite+cystine. In conclusion, the single energy micro CT with 80 kV can be used identifying cystine and struvite urinary stone.

  13. Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cai Weixing; Zhao Binghui; Conover, David

    2012-01-15

    Purpose: This research is designed to develop and evaluate a flat-panel detector-based dynamic cone beam CT system for dynamic angiography imaging, which is able to provide both dynamic functional information and dynamic anatomic information from one multirevolution cone beam CT scan. Methods: A dynamic cone beam CT scan acquired projections over four revolutions within a time window of 40 s after contrast agent injection through a femoral vein to cover the entire wash-in and wash-out phases. A dynamic cone beam CT reconstruction algorithm was utilized and a novel recovery method was developed to correct the time-enhancement curve of contrast flow.more » From the same data set, both projection-based subtraction and reconstruction-based subtraction approaches were utilized and compared to remove the background tissues and visualize the 3D vascular structure to provide the dynamic anatomic information. Results: Through computer simulations, the new recovery algorithm for dynamic time-enhancement curves was optimized and showed excellent accuracy to recover the actual contrast flow. Canine model experiments also indicated that the recovered time-enhancement curves from dynamic cone beam CT imaging agreed well with that of an IV-digital subtraction angiography (DSA) study. The dynamic vascular structures reconstructed using both projection-based subtraction and reconstruction-based subtraction were almost identical as the differences between them were comparable to the background noise level. At the enhancement peak, all the major carotid and cerebral arteries and the Circle of Willis could be clearly observed. Conclusions: The proposed dynamic cone beam CT approach can accurately recover the actual contrast flow, and dynamic anatomic imaging can be obtained with high isotropic 3D resolution. This approach is promising for diagnosis and treatment planning of vascular diseases and strokes.« less

  14. Improving the imaging of calcifications in CT by histogram-based selective deblurring

    NASA Astrophysics Data System (ADS)

    Rollano-Hijarrubia, Empar; van der Meer, Frits; van der Lugt, Add; Weinans, Harrie; Vrooman, Henry; Vossepoel, Albert; Stokking, Rik

    2005-04-01

    Imaging of small high-density structures, such as calcifications, with computed tomography (CT) is limited by the spatial resolution of the system. Blur causes small calcifications to be imaged with lower contrast and overestimated volume, thereby hampering the analysis of vessels. The aim of this work is to reduce the blur of calcifications by applying three-dimensional (3D) deconvolution. Unfortunately, the high-frequency amplification of the deconvolution produces edge-related ring artifacts and enhances noise and original artifacts, which degrades the imaging of low-density structures. A method, referred to as Histogram-based Selective Deblurring (HiSD), was implemented to avoid these negative effects. HiSD uses the histogram information to generate a restored image in which the low-intensity voxel information of the observed image is combined with the high-intensity voxel information of the deconvolved image. To evaluate HiSD we scanned four in-vitro atherosclerotic plaques of carotid arteries with a multislice spiral CT and with a microfocus CT (μCT), used as reference. Restored images were generated from the observed images, and qualitatively and quantitatively compared with their corresponding μCT images. Transverse views and maximum-intensity projections of restored images show the decrease of blur of the calcifications in 3D. Measurements of the areas of 27 calcifications and total volumes of calcification of 4 plaques show that the overestimation of calcification was smaller for restored images (mean-error: 90% for area; 92% for volume) than for observed images (143%; 213%, respectively). The qualitative and quantitative analyses show that the imaging of calcifications in CT can be improved considerably by applying HiSD.

  15. [Axial computer tomography of the neurocranium (author's transl)].

    PubMed

    Stöppler, L

    1977-05-27

    Computer tomography (CT), a new radiographic examination technique, is very highly efficient, for it has high informative content with little stress for the patient. In contrast to the conventional X-ray technology, CT succeeds, by direct presentation of the structure of the soft parts, in obtaining information which comes close to that of macroscopic neuropathology. The capacity and limitations of the method at the present stage of development are reported. Computer tomography cannot displace conventional neuroradiological methods of investigation, although it is rightly presented as a screening method and helps towards selective use. Indications, technical integration and handling of CT are prerequisites for the exhaustive benefit of the excellent new technique.

  16. Application of CT perfusion to assess hemodynamics in symptomatic Moyamoya syndrome: focus on affected side and parameter characteristic.

    PubMed

    Huang, Shuran; Gao, Lingyun; Chen, Yueqin; Guo, Xiang; Liu, Deguo; Wang, Jiehuan; Shi, Zhitao; Sun, Zhanguo; Jin, Feng; Chen, Weijian; Yang, Yunjun

    2018-01-27

    Vascular and hemodynamic changes were not consistent in symptomatic and non-symptomatic cerebral hemisphere in patients with symptomatic moyamoya syndrome (MMS). Thus, the purpose of this study is to evaluate the hemodynamic difference between symptomatic and non-symptomatic cerebral hemisphere in patients with symptomatic MMS. Patients who were diagnosed with symptomatic MMS were retrospectively collected. All cases underwent CTP examination. Regions of interest (ROIs) were chosen in the mirroring bilateral frontal lobes, temporal lobes, the basal ganglia, and the brainstem as control region. The relative perfusion parameter values of symptomatic side were compared with non-symptomatic side. Of the 40 patients, 33 patients were taken into assessment. In all cases (n = 33), rCBF, rMTT, and rTTP in all regions of interest (ROIs) of the symptomatic side were significantly different from those of contralateral side. In unilateral MMS patients (n = 7), rCBF values were not significantly different between two sides in the temporal lobe and basal ganglia area; rTTP values were significantly higher in the symptomatic side. rMTT values were significantly higher only in the temporal lobe of symptomatic side. In bilateral MMS patients (n = 26), rCBF and rMTT in all ROIs of the symptomatic side were significantly different from those of contralateral side. However, there were no significant differences between two sides in all ROIs on rTTP values. This study demonstrates that rCBF and rMTT were more sensitive than rTTP for evaluating hemodynamic changes in patients with symptomatic bilateral MMS. Furthermore, patients with unilateral MMS may have a preserved rCBF compared to those with bilateral disease.

  17. Initial Steps to inform selection of continuation cognitive therapy or fluoxetine for higher risk responders to cognitive therapy for recurrent major depressive disorder.

    PubMed

    Vittengl, Jeffrey R; Anna Clark, Lee; Thase, Michael E; Jarrett, Robin B

    2017-07-01

    Responders to acute-phase cognitive therapy (A-CT) for major depressive disorder (MDD) often relapse or recur, but continuation-phase cognitive therapy (C-CT) or fluoxetine reduces risks for some patients. We tested composite moderators of C-CT versus fluoxetine's preventive effects to inform continuation treatment selection. Responders to A-CT for MDD judged to be at higher risk for relapse due to unstable or partial remission (N=172) were randomized to 8 months of C-CT or fluoxetine with clinical management and assessed, free from protocol treatment, for 24 additional months. Pre-continuation-treatment characteristics that in survival analyses moderated treatments' effects on relapse over 8 months of continuation-phase treatment (residual symptoms and negative temperament) and on relapse/recurrence over the full observation period's 32 months (residual symptoms and age) were combined to estimate the potential advantage of C-CT versus fluoxetine for individual patients. Assigning patients to optimal continuation treatment (i.e., to C-CT or fluoxetine, depending on patients' pre-continuation-treatment characteristics) resulted in absolute reduction of relapse or recurrence risk by 16-21% compared to the other non-optimal treatment. Although these novel results require replication before clinical application, selecting optimal continuation treatment (i.e., personalizing treatment) for higher risk A-CT responders may decrease risks of MDD relapse and recurrence substantively. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  18. Distributed single source coding with side information

    NASA Astrophysics Data System (ADS)

    Vila-Forcen, Jose E.; Koval, Oleksiy; Voloshynovskiy, Sviatoslav V.

    2004-01-01

    In the paper we advocate image compression technique in the scope of distributed source coding framework. The novelty of the proposed approach is twofold: classical image compression is considered from the positions of source coding with side information and, contrarily to the existing scenarios, where side information is given explicitly, side information is created based on deterministic approximation of local image features. We consider an image in the transform domain as a realization of a source with a bounded codebook of symbols where each symbol represents a particular edge shape. The codebook is image independent and plays the role of auxiliary source. Due to the partial availability of side information at both encoder and decoder we treat our problem as a modification of Berger-Flynn-Gray problem and investigate a possible gain over the solutions when side information is either unavailable or available only at decoder. Finally, we present a practical compression algorithm for passport photo images based on our concept that demonstrates the superior performance in very low bit rate regime.

  19. Three-dimensional monochromatic x-ray CT

    NASA Astrophysics Data System (ADS)

    Saito, Tsuneo; Kudo, Hiroyuki; Takeda, Tohoru; Itai, Yuji; Tokumori, Kenji; Toyofuku, Fukai; Hyodo, Kazuyuki; Ando, Masami; Nishimura, Ktsuyuki; Uyama, Chikao

    1995-08-01

    In this paper, we describe a 3D computed tomography (3D CT) using monochromatic x-rays generated by synchrotron radiation, which performs a direct reconstruction of 3D volume image of an object from its cone-beam projections. For the develpment of 3D CT, scanning orbit of x-ray source to obtain complete 3D information about an object and corresponding 3D image reconstruction algorithm are considered. Computer simulation studies demonstrate the validities of proposed scanning method and reconstruction algorithm. A prototype experimental system of 3D CT was constructed. Basic phantom examinations and specific material CT image by energy subtraction obtained in this experimental system are shown.

  20. [Relevance of MRI After Closed Reduction of Traumatic Hip Dislocation in Children].

    PubMed

    Strüwind, Christoph Mauritz; von Rüden, Christian; Thannheimer, Andreas; Bühren, Volker; Schneidmueller, Dorien

    2018-05-14

    Traumatic hip dislocation in children and adolescents is a rare entity that typically results from high-energy trauma. After closed joint reduction, further treatment depends on the specific pattern of the lesion as identified using cross sectional imaging. The aim of this retrospective analysis was to evaluate relevant side effects after traumatic hip dislocation in children and adolescents in order to examine the need for focused diagnostics. This retrospective analysis covered 8 adolescents under 18 years suffering isolated traumatic hip joint dislocation between 2001 and 2017. In all patients, closed joint reduction was performed immediately after admission to the emergency room. In order to evaluate the complete extent of the injury, 5 patients received an MRI and 3 patients a CT scan following closed joint reduction. Two female and 6 male patients with a median age of 11 (range 5 - 16) years were included. In 2 cases, a free joint body was detected in the posterior joint gap in the posttraumatic CT scan after closed joint reduction. Interposition of the labrum into the joint gap was detected intraoperatively in both cases. In one patient who received posttraumatic MRI, labral interposition into the joint gap was observed after closed reduction. These findings were confirmed intraoperatively. In 4 other patients, no posttraumatic labral lesion was detected in the MRI after closed reduction. The reported side effects included ruptured anterior inferior iliac spine and ruptured femoral head ligament. MRI is gaining increasing importance following traumatic hip dislocation in children and adolescents. A missing chondral or osteochondral fragment in the CT scan does not exclude a labral lesion or interposition. Therefore, MRI following closed reduction is mandatory in any case. Georg Thieme Verlag KG Stuttgart · New York.

  1. Rotational malalignment after closed intramedullary nailing of femoral shaft fractures and its influence on daily life.

    PubMed

    Karaman, Ozgur; Ayhan, Egemen; Kesmezacar, Hayrettin; Seker, Ali; Unlu, Mehmet Can; Aydingoz, Onder

    2014-10-01

    Any intraoperative rotational malalignment during intramedullary nailing (IMN) of femoral shaft fractures will become permanent. We hypothesized that rotational malalignment of the femur and its compensatory biomechanics may induce problems in the hip, knee, patellofemoral and ankle joints. We purposed to clarify the influence of a femoral rotational malalignment of ≥10° on daily activities. Twenty-four femoral shaft fracture patients treated with closed antegrade IMN were included. At last follow-up, to reveal any rotational malalignment, computerized tomography (CT) scans of both femurs (injured and uninjured sides) were examined. The patient groups with or without CT-detected true rotational malalignment ≥10° were compared with respect to the activity scores. Ten of the 24 patients (41.7%) had a CT-detected true rotational malalignment of ≥10° compared with the unaffected side. The AOFAS scores were 100.00 for all of the patients. LKS, WOMAC knee, and WOMAC hip scores were significantly decreased in the patients with rotational malalignment compared to those without. Patients without rotational malalignment tolerated climbing stairs significantly better than those with rotational malalignment. Patients who could not tolerate climbing stairs were consistently complaining of anterior knee pain. A femoral rotational malalignment of ≥10° is symptomatic for the patients, and the hip, knee, and patellofemoral joints were affected. Because of the possibly altered joint loadings and biomechanics, these could render patients prone to degenerative joint disease. In addition, due to the high rates of rotational malalignment after femoral shaft fracture and consequent malpractice claims, it is important for surgeons to be more aware of rotational alignment during surgery.

  2. Comparision between Brain Atrophy and Subdural Volume to Predict Chronic Subdural Hematoma: Volumetric CT Imaging Analysis

    PubMed Central

    Ju, Min-Wook; Kwon, Hyon-Jo; Choi, Seung-Won; Koh, Hyeon-Song; Youm, Jin-Young; Song, Shi-Hun

    2015-01-01

    Objective Brain atrophy and subdural hygroma were well known factors that enlarge the subdural space, which induced formation of chronic subdural hematoma (CSDH). Thus, we identified the subdural volume that could be used to predict the rate of future CSDH after head trauma using a computed tomography (CT) volumetric analysis. Methods A single institution case-control study was conducted involving 1,186 patients who visited our hospital after head trauma from January 1, 2010 to December 31, 2014. Fifty-one patients with delayed CSDH were identified, and 50 patients with age and sex matched for control. Intracranial volume (ICV), the brain parenchyme, and the subdural space were segmented using CT image-based software. To adjust for variations in head size, volume ratios were assessed as a percentage of ICV [brain volume index (BVI), subdural volume index (SVI)]. The maximum depth of the subdural space on both sides was used to estimate the SVI. Results Before adjusting for cranium size, brain volume tended to be smaller, and subdural space volume was significantly larger in the CSDH group (p=0.138, p=0.021, respectively). The BVI and SVI were significantly different (p=0.003, p=0.001, respectively). SVI [area under the curve (AUC), 77.3%; p=0.008] was a more reliable technique for predicting CSDH than BVI (AUC, 68.1%; p=0.001). Bilateral subdural depth (sum of subdural depth on both sides) increased linearly with SVI (p<0.0001). Conclusion Subdural space volume was significantly larger in CSDH groups. SVI was a more reliable technique for predicting CSDH. Bilateral subdural depth was useful to measure SVI. PMID:27169071

  3. Comparision between Brain Atrophy and Subdural Volume to Predict Chronic Subdural Hematoma: Volumetric CT Imaging Analysis.

    PubMed

    Ju, Min-Wook; Kim, Seon-Hwan; Kwon, Hyon-Jo; Choi, Seung-Won; Koh, Hyeon-Song; Youm, Jin-Young; Song, Shi-Hun

    2015-10-01

    Brain atrophy and subdural hygroma were well known factors that enlarge the subdural space, which induced formation of chronic subdural hematoma (CSDH). Thus, we identified the subdural volume that could be used to predict the rate of future CSDH after head trauma using a computed tomography (CT) volumetric analysis. A single institution case-control study was conducted involving 1,186 patients who visited our hospital after head trauma from January 1, 2010 to December 31, 2014. Fifty-one patients with delayed CSDH were identified, and 50 patients with age and sex matched for control. Intracranial volume (ICV), the brain parenchyme, and the subdural space were segmented using CT image-based software. To adjust for variations in head size, volume ratios were assessed as a percentage of ICV [brain volume index (BVI), subdural volume index (SVI)]. The maximum depth of the subdural space on both sides was used to estimate the SVI. Before adjusting for cranium size, brain volume tended to be smaller, and subdural space volume was significantly larger in the CSDH group (p=0.138, p=0.021, respectively). The BVI and SVI were significantly different (p=0.003, p=0.001, respectively). SVI [area under the curve (AUC), 77.3%; p=0.008] was a more reliable technique for predicting CSDH than BVI (AUC, 68.1%; p=0.001). Bilateral subdural depth (sum of subdural depth on both sides) increased linearly with SVI (p<0.0001). Subdural space volume was significantly larger in CSDH groups. SVI was a more reliable technique for predicting CSDH. Bilateral subdural depth was useful to measure SVI.

  4. Evaluation of two minimal-preparation regimes for CT colonography: optimising image quality and patient acceptability.

    PubMed

    Pollentine, A; Mortimer, A; McCoubrie, P; Archer, L

    2012-08-01

    To compare a 2 day bowel preparation regime of barium, iodine and a mild stimulant laxative with a 1 day iodine-only regime for CT colonography (CTC). 100 consecutive patients underwent CTC. The first 50 patients (Regime 1) ingested 1 bisacodyl tablet twice a day 3 days before CTC and 1 dose each of 50 ml of barium and 20 ml of iodinated contrast per day starting 2 days before CTC. The second 50 patients (Regime 2) ingested 3 doses of iodinated contrast over 24 h prior to CTC. Volumes of residual stool and fluid, and the effectiveness of stool and fluid tagging, were graded according to methods established by Taylor et al (Taylor S, Slaker A, Burling D, Tam E, Greenhalgh R, Gartner L, et al. CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging. Eur Radiol 2008; 18: 32-42). A 3 day low-residue diet was taken by both cohorts. Questionnaires rating the side-effects and burden of the bowel preparation were compared to a control cohort of patients undergoing barium enema. The proportion of colons producing none/scattered stool (score 1) was 90.3% with Regime 1 and 65.0% with Regime 2 (p<0.005). Any residual stool was significantly better tagged with Regime 1 (score 5), with 91.7% of Regime 1 exhibiting optimum tagging vs 71.3% of Regime 2 (p<0.05). No significant differences in side-effects between the bowel preparation regimes for CTC were elicited. Bowel preparation for barium enema was tolerated significantly worse than both of the CTC bowel preparation regimes. Regime 1, containing a 3 day preparation of a mild laxative, barium and iodine, produced a significantly better prepared colon, with no difference in patient acceptability.

  5. Zhibitai and low-dose atorvastatin reduce blood lipids and inflammation in patients with coronary artery disease.

    PubMed

    Zhao, Yuhong; Peng, Ran; Zhao, Wang; Liu, Qiong; Guo, Yuan; Zhao, Shuiping; Xu, Danyan

    2017-02-01

    Atorvastatin decreases blood lipids but is associated with side effects. Zhibitai is a traditional Chinese medicine used to treat blood lipid disorders. The objective of this study is to evaluate the lipid-lowering effect, antiinflammatory effect, and adverse events of zhibitai combined to atorvastatin in patients with coronary heart diseases (CHDs). Patients with CHD (n = 150) were randomized to: zhibitai 480 mg + atorvastatin 10 mg (ZA10 group), atorvastatin 20 mg (A20 group), and atorvastatin 40 mg (A40 group). Lipid profile, cardiotrophin-1 (CT-1), and C-reactive protein (CRP) were measured after 4 and 8 weeks of treatment. Self-reported side effects, liver function, kidney function, and creatine kinase levels were monitored. After 8 weeks, triglycerides, total cholesterol (TC), LDL-cholesterol (LDL-C), and apolipoprotein B100 (ApoB100) levels were decreased in the ZA10 group (-64%, -37%, -46%, and -54%, respectively, compared with baseline), and these changes were similar to those of the A40 group (P > 0.05). CT-1 and high sensitivity-C reactive protein (hs-CRP) levels were significantly decreased in the ZA10 group after 4 and 8 weeks (4 weeks: -73% and 96%; 8 weeks: -89% and -98%; all P < 0.01), without differences among the 3 groups (P > 0.05). After 8 weeks of treatment, adverse events (abdominal distention, nausea, vomiting, and hunger) were found in 4, 5, and 7 patients in the ZA10, A20, and A40 groups, respectively. ZA10 significantly reduced triglycerides, TC, LDL-C, ApoB, CT-1, and hs-CRP levels in patients with CHD, similar to the effects of A40 and A20, but ZA10 lead to fewer adverse events.

  6. Experimental and molecular docking studies on DNA binding interaction of adefovir dipivoxil: Advances toward treatment of hepatitis B virus infections

    NASA Astrophysics Data System (ADS)

    Shahabadi, Nahid; Falsafi, Monireh

    The toxic interaction of adefovir dipivoxil with calf thymus DNA (CT-DNA) was investigated in vitro under simulated physiological conditions by multi-spectroscopic techniques and molecular modeling study. The fluorescence spectroscopy and UV absorption spectroscopy indicated drug interacted with CT-DNA in a groove binding mode. The binding constant of UV-visible and the number of binding sites were 3.33 ± 0.2 × 104 L mol-1and 0.99, respectively. The fluorimetric studies showed that the reaction between the drug and CT-DNA is exothermic (ΔH = 34.4 kJ mol-1; ΔS = 184.32 J mol-1 K-1). Circular dichroism spectroscopy (CD) was employed to measure the conformational change of CT-DNA in the presence of adefovir dipivoxil, which verified the groove binding mode. Furthermore, the drug induces detectable changes in its viscosity. The molecular modeling results illustrated that adefovir strongly binds to groove of DNA by relative binding energy of docked structure -16.83 kJ mol-1. This combination of multiple spectroscopic techniques and molecular modeling methods can be widely used in the investigation on the toxic interaction of small molecular pollutants and drugs with bio macromolecules, which contributes to clarify the molecular mechanism of toxicity or side effect in vivo.

  7. Multiple organ definition in CT using a Bayesian approach for 3D model fitting

    NASA Astrophysics Data System (ADS)

    Boes, Jennifer L.; Weymouth, Terry E.; Meyer, Charles R.

    1995-08-01

    Organ definition in computed tomography (CT) is of interest for treatment planning and response monitoring. We present a method for organ definition using a priori information about shape encoded in a set of biometric organ models--specifically for the liver and kidney-- that accurately represents patient population shape information. Each model is generated by averaging surfaces from a learning set of organ shapes previously registered into a standard space defined by a small set of landmarks. The model is placed in a specific patient's data set by identifying these landmarks and using them as the basis for model deformation; this preliminary representation is then iteratively fit to the patient's data based on a Bayesian formulation of the model's priors and CT edge information, yielding a complete organ surface. We demonstrate this technique using a set of fifteen abdominal CT data sets for liver surface definition both before and after the addition of a kidney model to the fitting; we demonstrate the effectiveness of this tool for organ surface definition in this low-contrast domain.

  8. Cortical venous thrombosis following exogenous androgen use for bodybuilding.

    PubMed

    Sveinsson, Olafur; Herrman, Lars

    2013-02-05

    There are only a few reports of patients developing cerebral venous sinus thrombosis (CVST) after androgen therapy. We present a young man who developed cortical venous thrombosis after using androgens to increase muscle mass. He was hospitalised for parasthesia and dyspraxia in the left hand followed by a generalised tonic-clonic seizure. At admission, he was drowsy, not fully orientated, had sensory inattention, pronation drift and a positive extensor response, all on the left side. The patient had been using anabolic steroids (dainabol 20 mg/day) for the last month for bodybuilding. CT angiography showed a right cortical venous thrombosis. Anticoagulation therapy was started with intravenous heparin for 11 days and oral anticoagulation (warfarin) thereafter. A control CT angiography 4 months later showed resolution of the thrombosis. He recovered fully.

  9. Recognition of xyloglucan by the crystalline cellulose-binding site of a family 3a carbohydrate-binding module

    PubMed Central

    Hernandez-Gomez, Mercedes C.; Rydahl, Maja G.; Rogowski, Artur; Morland, Carl; Cartmell, Alan; Crouch, Lucy; Labourel, Aurore; Fontes, Carlos M. G. A.; Willats, William G. T.; Gilbert, Harry J; Knox, J. Paul

    2018-01-01

    Type A non-catalytic carbohydrate-binding modules (CBMs), exemplified by CtCBM3acipA, are widely believed to specifically target crystalline cellulose through entropic forces. Here we have tested the hypothesis that type A CBMs can also bind to xyloglucan, a soluble β-1,4-glucan containing α-1,6-xylose side chains. CtCBM3acipA bound to xyloglucan in cell walls and arrayed on solid surfaces. Xyloglucan and cellulose were shown to bind to the same planar surface on CBM3acipA. A range of type A CBMs from different families were shown to bind to xyloglucan in solution with ligand binding driven by enthalpic changes. The nature of CBM-polysaccharide interactions is discussed. PMID:26193423

  10. 48. VIEW LOOKING NORTHEAST AT EXCITER RESISTANCE GRIDS LOCATED UNDER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. VIEW LOOKING NORTHEAST AT EXCITER RESISTANCE GRIDS LOCATED UNDER THE CONTROL ROOM ON SOUTH SIDE OF TURBINE HALL. THE GRIDS WERE AN ESSENTIAL PART OF THE CONTROL SYSTEM THAT MAINTAINED CONSTANT VOLTAGE ON THE RAILROAD POWER LINES. TIRRILL VOLTAGE REGULATORS (SEE CT-142A-100) SENSED VOLTAGE VARIATIONS AND INITIATED SWITCHING SEQUENCES TO REGULATE THE VOLTAGE AND MAINTAIN A SYSTEM STANDARD VOLTAGE. THE RESISTANCE GRIDS WERE SEQUENTIALLY ADDED TO OR REMOVED FROM THE GENERATOR FIELD COIL CIRCUITS. THIS RESISTANCE LOAD DISSIPATED EXCITIR GENERATOR POWER AS HEAT. THIS IN TURN WOULD VARY THE STRENGTH OF THE FIELD MAGNET AND CONSEQUENTLY RAISE OR LOWER THE OUTPUT VOLTAGE FROM THE MAIN GENERATOR ARMATURE. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  11. Comparative Investigation of Body Composition in Male Dogs Using CT and Body Fat Analysis Software

    PubMed Central

    KOBAYASHI, Toyokazu; KOIE, Hiroshi; KUSUMI, Akiko; KITAGAWA, Masato; KANAYAMA, Kiichi; OTSUJI, Kazuya

    2013-01-01

    ABSTRACT In small animal veterinary practices, body condition score (BCS) is generally used to diagnose obesity. However, BCS does not constitute objective data. In this study, we investigated the value of using human body fat analysis software for male dogs. We also compared changes in body fat after neutering. Changes in body fat at the time of neutering (age 1 year) and 1 year later were compared by performing CT scanning and using human body fat analysis software. We found that body fat increased in all the individuals tested. In terms of the site of fat accumulation, subcutaneous fat was more pronounced than visceral fat with a marked increase on the dorsal side of the abdomen rather than the thorax. PMID:24212506

  12. Oval Window Size and Shape: a Micro-CT Anatomical Study With Considerations for Stapes Surgery.

    PubMed

    Zdilla, Matthew J; Skrzat, Janusz; Kozerska, Magdalena; Leszczyński, Bartosz; Tarasiuk, Jacek; Wroński, Sebastian

    2018-06-01

    The oval window is an important structure with regard to stapes surgeries, including stapedotomy for the treatment of otosclerosis. Recent study of perioperative imaging of the oval window has revealed that oval window niche height can indicate both operative difficulty and subjective discomfort during otosclerosis surgery. With regard to shape, structures incorporated into the oval window niche, such as cartilage grafts, must be compatible with the shape of the oval window. Despite the clinical importance of the oval window, there is little information regarding its size and shape. This study assessed oval window size and shape via micro-computed tomography paired with modern morphometric methodology in the fetal, infant, child, and adult populations. Additionally, the study compared oval window size and shape between sexes and between left- and right-sided ears. No significant differences were found among traditional morphometric parameters among age groups, sides, or sexes. However, geometric morphometric methods revealed shape differences between age groups. Further, geometric morphometric methods provided the average oval window shape and most-likely shape variance. Beyond demonstrating oval window size and shape variation, the results of this report will aid in identifying patients among whom anatomical variation may contribute to surgical difficulty and surgeon discomfort, or otherwise warrant preoperative adaptations for the incorporation of materials into and around the oval window.

  13. Automatic quantification of mammary glands on non-contrast x-ray CT by using a novel segmentation approach

    NASA Astrophysics Data System (ADS)

    Zhou, Xiangrong; Kano, Takuya; Cai, Yunliang; Li, Shuo; Zhou, Xinxin; Hara, Takeshi; Yokoyama, Ryujiro; Fujita, Hiroshi

    2016-03-01

    This paper describes a brand new automatic segmentation method for quantifying volume and density of mammary gland regions on non-contrast CT images. The proposed method uses two processing steps: (1) breast region localization, and (2) breast region decomposition to accomplish a robust mammary gland segmentation task on CT images. The first step detects two minimum bounding boxes of left and right breast regions, respectively, based on a machine-learning approach that adapts to a large variance of the breast appearances on different age levels. The second step divides the whole breast region in each side into mammary gland, fat tissue, and other regions by using spectral clustering technique that focuses on intra-region similarities of each patient and aims to overcome the image variance caused by different scan-parameters. The whole approach is designed as a simple structure with very minimum number of parameters to gain a superior robustness and computational efficiency for real clinical setting. We applied this approach to a dataset of 300 CT scans, which are sampled with the equal number from 30 to 50 years-old-women. Comparing to human annotations, the proposed approach can measure volume and quantify distributions of the CT numbers of mammary gland regions successfully. The experimental results demonstrated that the proposed approach achieves results consistent with manual annotations. Through our proposed framework, an efficient and effective low cost clinical screening scheme may be easily implemented to predict breast cancer risk, especially on those already acquired scans.

  14. A Strange Case of Downward Displacement of a Deep Brain Stimulation Electrode 10 Years Following Implantation: The Gliding Movement of Snakes Theory.

    PubMed

    Iacopino, Domenico Gerardo; Maugeri, Rosario; Giugno, Antonella; Giller, Cole A

    2015-08-01

    Despite the best efforts to ensure stereotactic precision, deep brain stimulation (DBS) electrodes can wander from their intended position after implantation. We report a case of downward electrode migration 10 years following successful implantation in a patient with Parkinson disease. A 53-year-old man with Parkinson disease underwent bilateral implantation of DBS electrodes connected to a subclavicular 2-channel pulse generator. The generator was replaced 7 years later, and a computed tomography (CT) scan confirmed the correct position of both leads. The patient developed a gradual worsening affecting his right side 3 years later, 10 years after the original implantation. A CT scan revealed displacement of the left electrode inferiorly into the pons. The new CT scans and the CT scans obtained immediately after the implantation were merged within a stereotactic planning workstation (Brainlab). Comparing the CT scans, the distal end of the electrode was in the same position, the proximal tip being significantly more inferior. The size and configuration of the coiled portions of the electrode had not changed. At implantation, the length was 27.7 cm; after 10 years, the length was 30.6 cm. These data suggests that the electrode had been stretched into its new position rather than pushed. Clinicians evaluating patients with a delayed worsening should be aware of this rare event. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Effect of heat sink on the recurrence of small malignant hepatic tumors after radiofrequency ablation.

    PubMed

    Lin, Zheng-Yu; Li, Guo-Lin; Chen, Jin; Chen, Zhong-Wu; Chen, Yi-Ping; Lin, Sun-Zhi

    2016-12-01

    The aim of this study was to investigate the effect of heat sink on the recurrence of hepatic malignant tumors <3 cm after percutaneous radiofrequency ablation (RFA). This study included 564 hepatic malignant tumors <3 cm in 381 patients. Preoperative images were used to determine whether these tumors were adjacent to vessels, and the diameter of adjacent vessels was measured. RFA was performed computed tomography (CT), magnetic resonance imaging (MRI) and ultrasound (US) guidance, and postoperative imaging follow-up was then conducted. SPSS software version 17.0 was used for data processing, and the χ2 test was used for comparative analysis. Two-sided P < 0.05 indicated statistical significance. A total of 33 recurrences were found: 15 in the MR group (15/468), 12 in the US group (12/53), and 6 in the CT group (6/43). Of the 101 lesions adjacent to blood vessels larger than 3 mm, 20 showed recurrence: 10 in the MR group (10/77), 7 in the US group (7/17), and 3 in the CT group (3/7). The recurrence rate of perivascular lesions was higher than that of nonperivascular lesions, and the rate in the MR group was lower those in the US and CT groups. The curative effect of MRI-guided RFA is better than those of US- and CT-guided ablation. The heat sink effect is an important factor affecting recurrence of hepatic malignant tumors after RFA.

  16. True left-sided gallbladder: A case report and comparison with the literature for the different techniques of laparoscopic cholecystectomy for such anomalies.

    PubMed

    Saafan, Tamer; Hu, James Yi; Mahfouz, Ahmed-Emad; Abdelaal, Abdelrahman

    2018-01-01

    True left-sided gallbladder (LSG) is a rare finding that may present with symptoms similar to those of a normally positioned gallbladder. Moreover, it may be missed by preoperative imaging studies such as ultrasound, computed tomography (CT), magnetic resonance imaging (MRI), or endoscopic ultrasound. True left-sided gallbladder is a surgical challenge and surgical technique may need to be modified for the completion of laparoscopic cholecystectomy. In this case report, we present a case of true left-sided gallbladder that produced right-sided abdominal symptoms. Ultrasound of the abdomen failed to show the left-sided position of the gallbladder. MRI showed the gallbladder located to the left of the ligamentum teres underneath segment III of the liver. Intraoperatively, the gallbladder was grasped and retracted to the right under the falciform ligament and it was removed using classical right-sided ports with no modification to the technique. No complications were encountered intraoperatively or postoperatively. True LSG is a rare anomaly that may present with right-sided symptoms like normally positioned gallbladder. It may be missed in preoperative imaging studies and can be discovered only intraoperatively. Modification of laparoscopic ports, change in patient's position and/or surgeon's position, or conversion to open cholecystectomy may be needed for safe removal of the gallbladder. Classical technique of laparoscopic cholecystectomy is feasible for left-sided gallbladder. However, if the anatomy is not clear, modifications of the surgical technique may be necessary for the safe dissection of the gallbladder. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishnan, Kalpagam; Liu, Jeff; Kohli, Kirpal

    Purpose: Fusion of electrical impedance tomography (EIT) with computed tomography (CT) can be useful as a clinical tool for providing additional physiological information about tissues, but requires suitable fusion algorithms and validation procedures. This work explores the feasibility of fusing EIT and CT images using an algorithm for coregistration. The imaging performance is validated through feature space assessment on phantom contrast targets. Methods: EIT data were acquired by scanning a phantom using a circuit, configured for injecting current through 16 electrodes, placed around the phantom. A conductivity image of the phantom was obtained from the data using electrical impedance andmore » diffuse optical tomography reconstruction software (EIDORS). A CT image of the phantom was also acquired. The EIT and CT images were fused using a region of interest (ROI) coregistration fusion algorithm. Phantom imaging experiments were carried out on objects of different contrasts, sizes, and positions. The conductive medium of the phantoms was made of a tissue-mimicking bolus material that is routinely used in clinical radiation therapy settings. To validate the imaging performance in detecting different contrasts, the ROI of the phantom was filled with distilled water and normal saline. Spatially separated cylindrical objects of different sizes were used for validating the imaging performance in multiple target detection. Analyses of the CT, EIT and the EIT/CT phantom images were carried out based on the variations of contrast, correlation, energy, and homogeneity, using a gray level co-occurrence matrix (GLCM). A reference image of the phantom was simulated using EIDORS, and the performances of the CT and EIT imaging systems were evaluated and compared against the performance of the EIT/CT system using various feature metrics, detectability, and structural similarity index measures. Results: In detecting distilled and normal saline water in bolus medium, EIT as a stand-alone imaging system showed contrast discrimination of 47%, while the CT imaging system showed a discrimination of only 1.5%. The structural similarity index measure showed a drop of 24% with EIT imaging compared to CT imaging. The average detectability measure for CT imaging was found to be 2.375 ± 0.19 before fusion. After complementing with EIT information, the detectability measure increased to 11.06 ± 2.04. Based on the feature metrics, the functional imaging quality of CT and EIT were found to be 2.29% and 86%, respectively, before fusion. Structural imaging quality was found to be 66% for CT and 16% for EIT. After fusion, functional imaging quality improved in CT imaging from 2.29% to 42% and the structural imaging quality of EIT imaging changed from 16% to 66%. The improvement in image quality was also observed in detecting objects of different sizes. Conclusions: The authors found a significant improvement in the contrast detectability performance of CT imaging when complemented with functional imaging information from EIT. Along with the feature assessment metrics, the concept of complementing CT with EIT imaging can lead to an EIT/CT imaging modality which might fully utilize the functional imaging abilities of EIT imaging, thereby enhancing the quality of care in the areas of cancer diagnosis and radiotherapy treatment planning.« less

  18. PET-CT in oncological patients: analysis of informal care costs in cost-benefit assessment.

    PubMed

    Orlacchio, Antonio; Ciarrapico, Anna Micaela; Schillaci, Orazio; Chegai, Fabrizio; Tosti, Daniela; D'Alba, Fabrizio; Guazzaroni, Manlio; Simonetti, Giovanni

    2014-04-01

    The authors analysed the impact of nonmedical costs (travel, loss of productivity) in an economic analysis of PET-CT (positron-emission tomography-computed tomography) performed with standard contrast-enhanced CT protocols (CECT). From October to November 2009, a total of 100 patients referred to our institute were administered a questionnaire to evaluate the nonmedical costs of PET-CT. In addition, the medical costs (equipment maintenance and depreciation, consumables and staff) related to PET-CT performed with CECT and PET-CT with low-dose nonenhanced CT and separate CECT were also estimated. The medical costs were 919.3 euro for PET-CT with separate CECT, and 801.3 euro for PET-CT with CECT. Therefore, savings of approximately 13% are possible. Moreover, savings in nonmedical costs can be achieved by reducing the number of hospital visits required by patients undergoing diagnostic imaging. Nonmedical costs heavily affect patients' finances as well as having an indirect impact on national health expenditure. Our results show that PET-CT performed with standard dose CECT in a single session provides benefits in terms of both medical and nonmedical costs.

  19. Emergency physicians' attitudes and preferences regarding computed tomography, radiation exposure, and imaging decision support.

    PubMed

    Griffey, Richard T; Jeffe, Donna B; Bailey, Thomas

    2014-07-01

    Although computerized decision support for imaging is often recommended for optimizing computed tomography (CT) use, no studies have evaluated emergency physicians' (EPs') preferences regarding computerized decision support in the emergency department (ED). In this needs assessment, the authors sought to determine if EPs view overutilization as a problem, if they want decision support, and if so, the kinds of support they prefer. A 42-item, Web-based survey of EPs was developed and used to measure EPs' attitudes, preferences, and knowledge. Key contacts at local EDs sent letters describing the study to their physicians. Exploratory principal components analysis (PCA) was used to determine the underlying factor structure of multi-item scales, Cronbach's alpha was used to measure internal consistency of items on a scale, Spearman correlations were used to describe bivariate associations, and multivariable linear regression analysis was used to identify variables independently associated with physician interest in decision support. Of 235 surveys sent, 155 (66%) EPs responded. Five factors emerged from the PCA. EPs felt that: 1) CT overutilization is a problem in the ED (α = 0.75); 2) a patient's cumulative CT study count affects decisions of whether and what type of imaging study to order only some of the time (α = 0.75); 3) knowledge that a patient has had prior CT imaging for the same indication makes EPs less likely to order a CT (α = 0.42); 4) concerns about malpractice, patient satisfaction, or insistence on CTs affect CT ordering decisions (α = 0.62); and 5) EPs want decision support before ordering CTs (α = 0.85). Performance on knowledge questions was poor, with only 18% to 39% correctly responding to each of the three multiple-choice items about effective radiation doses of chest radiograph and single-pass abdominopelvic CT, as well as estimated increased risk of cancer from a 10-mSv exposure. Although EPs wanted information on patients' cumulative exposures, they feel inadequately familiar with this information to make use of it clinically. If provided with patients' cumulative radiation exposures from CT, 87% of EPs said that they would use this information to discuss imaging options with their patients. In the multiple regression model, which included all variables associated with interest in decision support at p < 0.10 in bivariate tests, items independently associated with EPs' greater interest in all types of decision support proposed included lower total knowledge scores, greater frequency that cumulative CT study count affects EP's decision to order CTs, and greater agreement that overutilization of CT is a problem and that awareness of multiple prior CTs for a given indication affects CT ordering decisions. Emergency physicians view overutilization of CT scans as a problem with potential for improvement in the ED and would like to have more information to discuss risks with their patients. EPs are interested in all types of imaging decision support proposed to help optimize imaging ordering in the ED and to reduce radiation to their patients. Findings reveal several opportunities that could potentially affect CT utilization. © 2014 by the Society for Academic Emergency Medicine.

  20. Emergency Physicians’ Attitudes and Preferences Regarding Computed Tomography, Radiation Exposure, and Imaging Decision Support

    PubMed Central

    Griffey, Richard T.; Jeffe, Donna B.; Bailey, Thomas

    2014-01-01

    Objectives Although computerized decision support for imaging is often recommended for optimizing computed tomography (CT) use, no studies have evaluated emergency physicians’ (EPs’) preferences regarding computerized decision support in the emergency department (ED). In this needs assessment, the authors sought to determine if EPs view overutilization as a problem, if they want decision support, and if so, the kinds of support they prefer. Methods A 42-item, Web-based survey of EPs was developed and used to measure EPs’ attitudes, preferences, and knowledge. Key contacts at local EDs sent letters describing the study to their physicians. Exploratory principal components analysis (PCA) was used to determine the underlying factor structure of multi-item scales, Cronbach’s alpha was used to measure internal consistency of items on a scale, Spearman correlations were used to describe bivariate associations, and multivariable linear regression analysis was used to identify variables independently associated with physician interest in decision support. Results Of 235 surveys sent, 155 (66%) EPs responded. Five factors emerged from the PCA. EPs felt that: 1) CT overutilization is a problem in the ED (α = 0.75); 2) a patient’s cumulative CT study count affects decisions of whether and what type of imaging study to order only some of the time (α = 0.75); 3) knowledge that a patient has had prior CT imaging for the same indication makes EPs less likely to order a CT (α = 0.42); 4) concerns about malpractice, patient satisfaction, or insistence on CTs affect CT ordering decisions (α = 0.62); and 5) EPs want decision support before ordering CTs (α = 0.85). Performance on knowledge questions was poor, with only 18% to 39% correctly responding to each of the three multiple-choice items about effective radiation doses of chest radiograph and single-pass abdominopelvic CT, as well as estimated increased risk of cancer from a 10-mSv exposure. Although EPs wanted information on patients’ cumulative exposures, they feel inadequately familiar with this information to make use of it clinically. If provided with patients’ cumulative radiation exposures from CT, 87% of EPs said that they would use this information to discuss imaging options with their patients. In the multiple regression model, which included all variables associated with interest in decision support at p < 0.10 in bivariate tests, items independently associated with EPs’ greater interest in all types of decision support proposed included lower total knowledge scores, greater frequency that cumulative CT study count affects EP’s decision to order CTs, and greater agreement that overutilization of CT is a problem and that awareness of multiple prior CTs for a given indication affects CT ordering decisions. Conclusions Emergency physicians view overutilization of CT scans as a problem with potential for improvement in the ED and would like to have more information to discuss risks with their patients. EPs are interested in all types of imaging decision support proposed to help optimize imaging ordering in the ED and to reduce radiation to their patients. Findings reveal several opportunities that could potentially affect CT utilization. PMID:25125272

  1. Establishment of a voluntary electronic Chlamydia trachomatis laboratory surveillance system in Germany, 2008 to 2014

    PubMed Central

    Dudareva-Vizule, Sandra; Haar, Karin; Sailer, Andrea; Jansen, Klaus; Hamouda, Osamah; Wisplinghoff, Hilmar; Tiemann, Carsten; Pape, Eberhard; Bremer, Viviane

    2017-01-01

    Chlamydia trachomatis (CT) infections are not reportable in Germany and limited data on prevalence are available. CT screening has been offered free of charge to pregnant women since 1995 and to all women under 25 years since 2008. For symptomatic women and men, diagnostic testing is covered by statutory health insurance. We describe the establishment of a nationwide, laboratory-based, voluntary sentinel that electronically collects information on all performed CT tests with test results, test reason and patient information. The sentinel represents one third of all performed CT tests in Germany. In the period from 2008 to 2014, 3,877,588 CT tests were reported, 93% in women. Women aged 20–24 years and men aged 25–29 years were the most frequently tested age groups. The overall proportion of positive tests (PPT) among women was 3.9% and among men 11.0%. The highest PPT among women was in the age groups 15–19 (6.8%) and 20–24 years (5.9%), and among men in the age groups 20–24 (19.2%), 15–19 (15.4%) and 25–29 years (14.8%). The PPT for CT was high among women and men younger than 25 years. Prevention is urgently needed. Monitoring of CT infection in Germany should be continued. PMID:28205505

  2. CT vs. MRCP in choledocholithiasis jaundice.

    PubMed

    Petrescu, I; Bratu, A M; Petrescu, S; Popa, B V; Cristian, D; Burcos, T

    2015-01-01

    Obstructive jaundice can raise problems to diagnostic imaging. The radiologist must choose the most appropriate examination that delivers the most important diagnostic information because the differences between a lithiasic obstruction and a tumoral one are vital. This information helps the surgeon speed up the process of decision-making, because the treatment may be very different in relation to the nature of the obstruction. This study tries to demonstrate the diagnostic accuracy of computed tomography (CT) and magnetic resonance cholangiopancreatography (MRCP) in detecting the obstacle in the common bile duct (CBD) and the possibility of establishing the lithiasic nature of the obstruction. A retrospective analysis was analyzed during an interval of 18 months that included jaundice patients admitted in the General Surgery Department of "Coltea" Clinical Hospital. They were examined by CT scanning and by MRCP, being suspected of choledocholithiasis. 63 patients were included in the study, 34 females and 29 males. 33 CT scans and 30 MRCP exams were performed. CT scan is useful in detecting residual or iterative choledocholithiasis in patients after cholecystectomy, contrast enhanced CT (CECT), being able to differentiate between lithiasic and non-lithiasic obstruction. MRCP delivers important anatomic details of the biliary tree; it is superior to CT in diagnosing the hepatocholedochal lithiasis; MRCP tends to replace endoscopic retrograde cholangiopancreatography (ERCP)--the diagnostic "gold standard" reducing the number of unnecessary invasive diagnostic procedures.

  3. Cupping artifact correction and automated classification for high-resolution dedicated breast CT images.

    PubMed

    Yang, Xiaofeng; Wu, Shengyong; Sechopoulos, Ioannis; Fei, Baowei

    2012-10-01

    To develop and test an automated algorithm to classify the different tissues present in dedicated breast CT images. The original CT images are first corrected to overcome cupping artifacts, and then a multiscale bilateral filter is used to reduce noise while keeping edge information on the images. As skin and glandular tissues have similar CT values on breast CT images, morphologic processing is used to identify the skin mask based on its position information. A modified fuzzy C-means (FCM) classification method is then used to classify breast tissue as fat and glandular tissue. By combining the results of the skin mask with the FCM, the breast tissue is classified as skin, fat, and glandular tissue. To evaluate the authors' classification method, the authors use Dice overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on eight patient images. The correction method was able to correct the cupping artifacts and improve the quality of the breast CT images. For glandular tissue, the overlap ratios between the authors' automatic classification and manual segmentation were 91.6% ± 2.0%. A cupping artifact correction method and an automatic classification method were applied and evaluated for high-resolution dedicated breast CT images. Breast tissue classification can provide quantitative measurements regarding breast composition, density, and tissue distribution.

  4. Establishment of a voluntary electronic Chlamydia trachomatis laboratory surveillance system in Germany, 2008 to 2014.

    PubMed

    Dudareva-Vizule, Sandra; Haar, Karin; Sailer, Andrea; Jansen, Klaus; Hamouda, Osamah; Wisplinghoff, Hilmar; Tiemann, Carsten; Pape, Eberhard; Bremer, Viviane

    2017-02-09

    Chlamydia trachomatis (CT) infections are not reportable in Germany and limited data on prevalence are available. CT screening has been offered free of charge to pregnant women since 1995 and to all women under 25 years since 2008. For symptomatic women and men, diagnostic testing is covered by statutory health insurance. We describe the establishment of a nationwide, laboratory-based, voluntary sentinel that electronically collects information on all performed CT tests with test results, test reason and patient information. The sentinel represents one third of all performed CT tests in Germany. In the period from 2008 to 2014, 3,877,588 CT tests were reported, 93% in women. Women aged 20-24 years and men aged 25-29 years were the most frequently tested age groups. The overall proportion of positive tests (PPT) among women was 3.9% and among men 11.0%. The highest PPT among women was in the age groups 15-19 (6.8%) and 20-24 years (5.9%), and among men in the age groups 20-24 (19.2%), 15-19 (15.4%) and 25-29 years (14.8%). The PPT for CT was high among women and men younger than 25 years. Prevention is urgently needed. Monitoring of CT infection in Germany should be continued. This article is copyright of The Authors, 2017.

  5. Survey of computed tomography scanners in Taiwan: Dose descriptors, dose guidance levels, and effective doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, H. Y.; Tung, C. J.; Yu, C. C.

    2007-04-15

    The IAEA and the ICRP recommended dose guidance levels for the most frequent computed tomography (CT) examinations to promote strategies for the optimization of radiation dose to CT patients. A national survey, including on-site measurements and questionnaires, was conducted in Taiwan in order to establish dose guidance levels and evaluate effective doses for CT. The beam quality and output and the phantom doses were measured for nine representative CT scanners. Questionnaire forms were completed by respondents from facilities of 146 CT scanners out of 285 total scanners. Information on patient, procedure, scanner, and technique for the head and body examinationsmore » was provided. The weighted computed tomography dose index (CTDI{sub w}), the dose length product (DLP), organ doses and effective dose were calculated using measured data, questionnaire information and Monte Carlo simulation results. A cost-effective analysis was applied to derive the dose guidance levels on CTDI{sub w} and DLP for several CT examinations. The mean effective dose{+-}standard deviation distributes from 1.6{+-}0.9 mSv for the routine head examination to 13{+-}11 mSv for the examination of liver, spleen, and pancreas. The surveyed results and the dose guidance levels were provided to the national authorities to develop quality control standards and protocols for CT examinations.« less

  6. Micro-CT of rodents: state-of-the-art and future perspectives

    PubMed Central

    Clark, D. P.; Badea, C. T.

    2014-01-01

    Micron-scale computed tomography (micro-CT) is an essential tool for phenotyping and for elucidating diseases and their therapies. This work is focused on preclinical micro-CT imaging, reviewing relevant principles, technologies, and applications. Commonly, micro-CT provides high-resolution anatomic information, either on its own or in conjunction with lower-resolution functional imaging modalities such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT). More recently, however, advanced applications of micro-CT produce functional information by translating clinical applications to model systems (e.g. measuring cardiac functional metrics) and by pioneering new ones (e.g. measuring tumor vascular permeability with nanoparticle contrast agents). The primary limitations of micro-CT imaging are the associated radiation dose and relatively poor soft tissue contrast. We review several image reconstruction strategies based on iterative, statistical, and gradient sparsity regularization, demonstrating that high image quality is achievable with low radiation dose given ever more powerful computational resources. We also review two contrast mechanisms under intense development. The first is spectral contrast for quantitative material discrimination in combination with passive or actively targeted nanoparticle contrast agents. The second is phase contrast which measures refraction in biological tissues for improved contrast and potentially reduced radiation dose relative to standard absorption imaging. These technological advancements promise to develop micro-CT into a commonplace, functional and even molecular imaging modality. PMID:24974176

  7. Cupping artifact correction and automated classification for high-resolution dedicated breast CT images

    PubMed Central

    Yang, Xiaofeng; Wu, Shengyong; Sechopoulos, Ioannis; Fei, Baowei

    2012-01-01

    Purpose: To develop and test an automated algorithm to classify the different tissues present in dedicated breast CT images. Methods: The original CT images are first corrected to overcome cupping artifacts, and then a multiscale bilateral filter is used to reduce noise while keeping edge information on the images. As skin and glandular tissues have similar CT values on breast CT images, morphologic processing is used to identify the skin mask based on its position information. A modified fuzzy C-means (FCM) classification method is then used to classify breast tissue as fat and glandular tissue. By combining the results of the skin mask with the FCM, the breast tissue is classified as skin, fat, and glandular tissue. To evaluate the authors’ classification method, the authors use Dice overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on eight patient images. Results: The correction method was able to correct the cupping artifacts and improve the quality of the breast CT images. For glandular tissue, the overlap ratios between the authors’ automatic classification and manual segmentation were 91.6% ± 2.0%. Conclusions: A cupping artifact correction method and an automatic classification method were applied and evaluated for high-resolution dedicated breast CT images. Breast tissue classification can provide quantitative measurements regarding breast composition, density, and tissue distribution. PMID:23039675

  8. Charge versus Energy Transfer Effects in High-Performance Perylene Diimide Photovoltaic Blend Films.

    PubMed

    Singh, Ranbir; Shivanna, Ravichandran; Iosifidis, Agathaggelos; Butt, Hans-Jürgen; Floudas, George; Narayan, K S; Keivanidis, Panagiotis E

    2015-11-11

    Perylene diimide (PDI)-based organic photovoltaic devices can potentially deliver high power conversion efficiency values provided the photon energy absorbed is utilized efficiently in charge transfer (CT) reactions instead of being consumed in nonradiative energy transfer (ET) steps. Hitherto, it remains unclear whether ET or CT primarily drives the photoluminescence (PL) quenching of the PDI excimer state in PDI-based blend films. Here, we affirm the key role of the thermally assisted PDI excimer diffusion and subsequent CT reaction in the process of PDI excimer PL deactivation. For our study we perform PL quenching experiments in the model PDI-based composite made of poly[4,8-bis(5-(2-ethylhexyl)thiophen-2-yl)benzo[1,2-b;4,5-b']dithiophene-2,6-diyl-alt-(4-(2-ethylhexanoyl)-thieno[3,4-b]thiophene)-2-6-diyl] (PBDTTT-CT) polymeric donor mixed with the N,N'-bis(1-ethylpropyl)-perylene-3,4,9,10-tetracarboxylic diimide (PDI) acceptor. Despite the strong spectral overlap between the PDI excimer PL emission and UV-vis absorption of PBDTTT-CT, two main observations indicate that no significant ET component operates in the overall PL quenching: the PL intensity of the PDI excimer (i) increases with decreasing temperature and (ii) remains unaffected even in the presence of 10 wt % content of the PBDTTT-CT quencher. Temperature-dependent wide-angle X-ray scattering experiments further indicate that nonradiative resonance ET is highly improbable due to the large size of PDI domains. The dominance of the CT over the ET process is verified by the high performance of devices with an optimum composition of 30:70 PBDTTT-CT:PDI. By adding 0.4 vol % of 1,8-diiodooctane we verify the plasticization of the polymer side chains that balances the charge transport properties of the PBDTTT-CT:PDI composite and results in additional improvement in the device efficiency. The temperature-dependent spectral width of the PDI excimer PL band suggests the presence of energetic disorder in the PDI excimer excited state manifold.

  9. SU-E-J-252: A Motion Algorithm to Extract Physical and Motion Parameters of a Mobile Target in Cone-Beam Computed Tomographic Imaging Retrospective to Image Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, I; Ahmad, S; Alsbou, N

    Purpose: A motion algorithm was developed to extract actual length, CT-numbers and motion amplitude of a mobile target imaged with cone-beam-CT (CBCT) retrospective to image-reconstruction. Methods: The motion model considered a mobile target moving with a sinusoidal motion and employed three measurable parameters: apparent length, CT number level and gradient of a mobile target obtained from CBCT images to extract information about the actual length and CT number value of the stationary target and motion amplitude. The algorithm was verified experimentally with a mobile phantom setup that has three targets with different sizes manufactured from homogenous tissue-equivalent gel material embeddedmore » into a thorax phantom. The phantom moved sinusoidal in one-direction using eight amplitudes (0–20mm) and a frequency of 15-cycles-per-minute. The model required imaging parameters such as slice thickness, imaging time. Results: This motion algorithm extracted three unknown parameters: length of the target, CT-number-level, motion amplitude for a mobile target retrospective to CBCT image reconstruction. The algorithm relates three unknown parameters to measurable apparent length, CT-number-level and gradient for well-defined mobile targets obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on actual length of the target and motion amplitude. The cumulative CT-number for a mobile target was dependent on CT-number-level of the stationary target and motion amplitude. The gradient of the CT-distribution of mobile target is dependent on the stationary CT-number-level, actual target length along the direction of motion, and motion amplitude. Motion frequency and phase did not affect the elongation and CT-number distributions of mobile targets when imaging time included several motion cycles. Conclusion: The motion algorithm developed in this study has potential applications in diagnostic CT imaging and radiotherapy to extract actual length, size and CT-numbers distorted by motion in CBCT imaging. The model provides further information about motion of the target.« less

  10. 48. Photocopy of photograph (original negative is property of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. Photocopy of photograph (original negative is property of the Central Connecticut Regional Water Authority and preserved in their archives at 90 Sargent Drive, New Haven, Connecticut 06511-5966), photographer unknown, circa 1935. Loading dirty sand into an ejector for transport to the sand washer. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  11. 42. Photocopy of photograph (original negative is property of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. Photocopy of photograph (original negative is property of the Central Connecticut Regional Water Authority and preserved in their archives at 90 Sargent Drive, New Haven, Connecticut 06511-5966), photographer and date unknown. Mixing concrete for the construction of the slow sand filter circa 1903. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  12. 44. Photocopy of photograph (original negative is property of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. Photocopy of photograph (original negative is property of the Central Connecticut Regional Water Authority and preserved in their archives at 90 Sargent Drive, New Haven, Connecticut 06511-5966), photographer unknown, circa 1904. View of bricklayers erecting exterior walls on the slow sand filter. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  13. 47. Photocopy of photograph (original negative is property of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. Photocopy of photograph (original negative is property of the Central Connecticut Regional Water Authority and preserved in their archives at 90 Sargent Drive, New Haven, Connecticut 06511-5966), photographer and date unknown. View of main gallery between filter beds at Whitney Filtration Plant. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  14. 43. Photocopy of photograph (original negative is property of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. Photocopy of photograph (original negative is property of the Central Connecticut Regional Water Authority and preserved in their archives at 90 Sargent Drive, New Haven, Connecticut 06511-5966), photographer and date unknown. View of forms used to create walls for the slow sand filter. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  15. Photocopy of a photograph showing a woman (not E.E. Lape, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of a photograph showing a woman (not E.E. Lape, but possibly E.F. Read) seated outside of southwest corner of Murdock House (circa 1930s?). (Photo found in Lape-Read House, located at U.S. Fish and Wildlife Service - Murdock Hill, Murdock House, South side of Old Clinton Road (U.S. Route 1), 1 mile east of Horse Hill Road, Westbrook, Middlesex County, CT

  16. 51. Photocopy of photograph (original negative is property of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. Photocopy of photograph (original negative is property of the Central Connecticut Regional Water Authority and preserved in their archives at 90 Sargent Drive, New Haven, Connecticut 06511-5966), photographer unknown, circa 1960. Dr. Samuel Jacobson examining samples of water cultured on agar material. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  17. 52. Photocopy of photograph (original negative is property of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    52. Photocopy of photograph (original negative is property of the Central Connecticut Regional Water Authority and preserved in their archives at 90 Sargent Drive, New Haven, Connecticut 06511-5966), photographer unknown, circa 1960. The Whitney Filtration Plant Laboratory with Dr. Samuel Jacobson at work. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  18. CT colonography with reduced bowel preparation after incomplete colonoscopy in the elderly.

    PubMed

    Iafrate, F; Hassan, C; Zullo, A; Stagnitti, A; Ferrari, R; Spagnuolo, A; Laghi, A

    2008-07-01

    We prospectively assessed the feasibility and acceptance of computerized tomographic colonography (CTC) without bowel cathartic preparation in elderly patients after incomplete colonoscopy. A total of 136 patients underwent CTC without cathartic preparation. The time delay between conventional colonoscopy and CTC ranged between 3 and 20 days, depending on the clinical situation. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. CTCs were interpreted using a primary two-dimensional (2D) approach and 3D images for further characterization. Patients were interviewed before and 2 weeks after CTC to assess preparation acceptance. CTC was feasible and technically successful in all the 136 patients. Fecal tagging was judged as excellent in 113 (83%) patients and sufficient in 23 (17%). Average CT image interpretation time was 14.8 min. Six (4.4%) cases of colorectal cancer and nine (6.6%) large polyps were detected, as well as 23 (11.3%) extracolonic findings of high clinical importance. No major side effect occurred, although 25% patients reported minor side effects, especially diarrhea. Overall, 76/98 patients replied that they would be willing to repeat the test if necessary. CTC without cathartic preparation is a technically feasible and safe procedure to complete a colonic study in the elderly, prompting its use in clinical practice.

  19. Facial nerve conduction after sclerotherapy in children with facial lymphatic malformations: report of two cases.

    PubMed

    Lin, Pei-Jung; Guo, Yuh-Cherng; Lin, Jan-You; Chang, Yu-Tang

    2007-04-01

    Surgical excision is thought to be the standard treatment of choice for lymphatic malformations. However, when the lesions are limited to the face only, surgical scar and facial nerve injury may impair cosmetics and facial expression. Sclerotherapy, an injection of a sclerosing agent directly through the skin into a lesion, is an alternative method. By evaluating facial nerve conduction, we observed the long-term effect of facial lymphatic malformations after intralesional injection of OK-432 and correlated the findings with anatomic outcomes. One 12-year-old boy with a lesion over the right-side preauricular area adjacent to the main trunk of facial nerve and the other 5-year-old boy with a lesion in the left-sided cheek involving the buccinator muscle were enrolled. The follow-up data of more than one year, including clinical appearance, computed tomography (CT) scan and facial nerve evaluation were collected. The facial nerve conduction study was normal in both cases. Blink reflex in both children revealed normal results as well. Complete resolution was noted on outward appearance and CT scan. The neurophysiologic data were compatible with good anatomic and functional outcomes. Our report suggests that the inflammatory reaction of OK-432 did not interfere with adjacent facial nerve conduction.

  20. Biological Evaluation of Implant Drill Made from Zirconium Dioxide.

    PubMed

    Akiba, Yosuke; Eguchi, Kaori; Akiba, Nami; Uoshima, Katsumi

    2017-04-01

    Zirconia is a good candidate material in the dental field. In this study, we evaluated biological responses against a zirconia drill using a bone cavity healing model. Zirconia drills, stainless steel drills, and the drilled bone surface were observed by scanning electron microscopy (SEM), before and after cavity preparation. For the bone cavity healing model, the upper first and second molars of Wistar rats were extracted. After 4 weeks, cavities were prepared with zirconia drills on the left side. As a control, a stainless steel drill was used on the right side. At 3, 7, and 14 days after surgery, micro-CT images were taken. Samples were prepared for histological staining. SEM images revealed that zirconia drills maintained sharpness even after 30 drilling procedures. The bone surface was smoother with the zirconia drill. Micro-CT images showed faster and earlier bone healing in the zirconia drill cavity. On H-E staining, at 7 days, the zirconia drill defect had a smaller blank lacunae area. At 14 days, the zirconia drill defect was filled with newly formed bone. The zirconia drill induces less damage during cavity preparation and is advantageous for bone healing. (197 words). © 2016 The Authors Clinical Implant Dentistry and Related Research Published by Wiley Periodicals, Inc.

Top