Sample records for ct-based virtual colonoscopy

  1. [Virtual colonoscopy is now reality].

    PubMed

    Pedersen, Bodil Ginnerup; Achiam, Michael P; Arnesen, Regnar Bøge

    2005-10-31

    Virtual colonoscopy involves a helical CT or MR scan of the abdomen and pelvis to detect colorectal polyps and cancer. Both modalities have shown promising sensitivity in revealing larger polyps, in comparison with colonoscopy. Caution should be exercised in its clinical implementation due to significant interobserver variation and individual learning curves. A Danish study indicates that CT colonography (CTC) can be performed cost-effectively compared to colonoscopy. CTC is recommended in preference to double-contrast barium enema after incomplete colonoscopy.

  2. Whole-Body CT Screening--Should I or Shouldn't I Get One?

    MedlinePlus

    ... lung cancer in smokers of particular ages, CT virtual colonoscopy is as good as colonoscopy in men ... that resemble the disease or condition which in reality would not hurt you, when the test doesn' ...

  3. Image-based path planning for automated virtual colonoscopy navigation

    NASA Astrophysics Data System (ADS)

    Hong, Wei

    2008-03-01

    Virtual colonoscopy (VC) is a noninvasive method for colonic polyp screening, by reconstructing three-dimensional models of the colon using computerized tomography (CT). In virtual colonoscopy fly-through navigation, it is crucial to generate an optimal camera path for efficient clinical examination. In conventional methods, the centerline of the colon lumen is usually used as the camera path. In order to extract colon centerline, some time consuming pre-processing algorithms must be performed before the fly-through navigation, such as colon segmentation, distance transformation, or topological thinning. In this paper, we present an efficient image-based path planning algorithm for automated virtual colonoscopy fly-through navigation without the requirement of any pre-processing. Our algorithm only needs the physician to provide a seed point as the starting camera position using 2D axial CT images. A wide angle fisheye camera model is used to generate a depth image from the current camera position. Two types of navigational landmarks, safe regions and target regions are extracted from the depth images. Camera position and its corresponding view direction are then determined using these landmarks. The experimental results show that the generated paths are accurate and increase the user comfort during the fly-through navigation. Moreover, because of the efficiency of our path planning algorithm and rendering algorithm, our VC fly-through navigation system can still guarantee 30 FPS.

  4. Pneumoperitoneum after virtual colonoscopy: causes, risk factors, and management.

    PubMed

    Baccaro, Leopoldo M; Markelov, Alexey; Wilhelm, Jakub; Bloch, Robert

    2014-06-01

    Computed tomographic virtual colonoscopy (CTVC) is a safe and minimally invasive modality when compared with fiberoptic colonoscopy for evaluating the colon and rectum. We have reviewed the risks for colonic perforation by investigating the relevant literature. The objectives of this study were to assess the risk of colonic perforation during CTVC, describe risk factors, evaluate ways to reduce the incidence complications, and to review management and treatment options. A formal search of indexed publications was performed through PubMed. Search queries using keywords "CT colonography," "CT virtual colonoscopy," "virtual colonoscopy," and "perforation" yielded a total of 133 articles. A total of eight case reports and four review articles were selected. Combining case reports and review articles, a total of 25 cases of colonic perforation after CTVC have been reported. Causes include, but are not limited to, diverticular disease, irritable bowel diseases, obstructive processes, malignancies, and iatrogenic injury. Both operative and nonoperative management has been described. Nonoperative management has been proven safe and successful in minimally symptomatic and stable patients. Colonic perforation after CTVC is a rare complication and very few cases have been reported. Several risk factors are recurrent in the literature and must be acknowledged at the time of the study. Management options vary and should be tailored to each individual patient.

  5. Dual modality virtual colonoscopy workstation: design, implementation, and preliminary evaluation

    NASA Astrophysics Data System (ADS)

    Chen, Dongqing; Meissner, Michael

    2006-03-01

    The aim of this study is to develop a virtual colonoscopy (VC) workstation that supports both CT (computed tomography) and MR (magnetic resonance) imaging procedures. The workflow should be optimized and be able to take advantage of both image modalities. The technological break through is at the real-time volume rendering of spatial-intensity-inhomogeneous MR images to achieve high quality 3D endoluminal view. VC aims at visualizing CT or MR tomography images for detection of colonic polyp and lesion. It is also called as CT/MR colonography based on the imaging modality that is employed. The published results of large scale clinical trial demonstrated more than 90% of sensitivity on polyp detection for certain CT colonography (CTC) workstation. A drawback of the CT colonoscopy is the radiation exposure. MR colonography (MRC) is free from the X-ray radiation. It achieved almost 100% specificity for polyp detection in published trials. The better tissue contrast in MR image allows the accurate diagnosis of inflammatory bowel disease also, which is usually difficult in CTC. At present, most of the VC workstations are designed for CT examination. They are not able to display multi-sequence MR series concurrently in a single application. The automatic correlation between 2D and 3D view is not available due to the difficulty of 3D model building for MR images. This study aims at enhancing a commercial VC product that was successfully used for CTC to equally support dark-lumen protocol MR procedure also.

  6. Virtual Colonoscopy Screening With Ultra Low-Dose CT and Less-Stressful Bowel Preparation: A Computer Simulation Study

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Wang, Su; Li, Lihong; Fan, Yi; Lu, Hongbing; Liang, Zhengrong

    2008-10-01

    Computed tomography colonography (CTC) or CT-based virtual colonoscopy (VC) is an emerging tool for detection of colonic polyps. Compared to the conventional fiber-optic colonoscopy, VC has demonstrated the potential to become a mass screening modality in terms of safety, cost, and patient compliance. However, current CTC delivers excessive X-ray radiation to the patient during data acquisition. The radiation is a major concern for screening application of CTC. In this work, we performed a simulation study to demonstrate a possible ultra low-dose CT technique for VC. The ultra low-dose abdominal CT images were simulated by adding noise to the sinograms of the patient CTC images acquired with normal dose scans at 100 mA s levels. The simulated noisy sinogram or projection data were first processed by a Karhunen-Loeve domain penalized weighted least-squares (KL-PWLS) restoration method and then reconstructed by a filtered backprojection algorithm for the ultra low-dose CT images. The patient-specific virtual colon lumen was constructed and navigated by a VC system after electronic colon cleansing of the orally-tagged residue stool and fluid. By the KL-PWLS noise reduction, the colon lumen can successfully be constructed and the colonic polyp can be detected in an ultra low-dose level below 50 mA s. Polyp detection can be found more easily by the KL-PWLS noise reduction compared to the results using the conventional noise filters, such as Hanning filter. These promising results indicate the feasibility of an ultra low-dose CTC pipeline for colon screening with less-stressful bowel preparation by fecal tagging with oral contrast.

  7. Colonoscopy tutorial software made with a cadaver's sectioned images.

    PubMed

    Chung, Beom Sun; Chung, Min Suk; Park, Hyung Seon; Shin, Byeong-Seok; Kwon, Koojoo

    2016-11-01

    Novice doctors may watch tutorial videos in training for actual or computed tomographic (CT) colonoscopy. The conventional learning videos can be complemented by virtual colonoscopy software made with a cadaver's sectioned images (SIs). The objective of this study was to assist colonoscopy trainees with the new interactive software. Submucosal segmentation on the SIs was carried out through the whole length of the large intestine. With the SIs and segmented images, a three dimensional model was reconstructed. Six-hundred seventy-one proximal colonoscopic views (conventional views) and corresponding distal colonoscopic views (simulating the retroflexion of a colonoscope) were produced. Not only navigation views showing the current location of the colonoscope tip and its course, but also, supplementary description views were elaborated. The four corresponding views were put into convenient browsing software to be downloaded free from the homepage (anatomy.co.kr). The SI colonoscopy software with the realistic images and supportive tools was available to anybody. Users could readily notice the position and direction of the virtual colonoscope tip and recognize meaningful structures in colonoscopic views. The software is expected to be an auxiliary learning tool to improve technique and related knowledge in actual and CT colonoscopies. Hopefully, the software will be updated using raw images from the Visible Korean project. Copyright © 2016 Elsevier GmbH. All rights reserved.

  8. Virtual gastrointestinal colonoscopy in combination with large bowel endoscopy: Clinical application

    PubMed Central

    He, Qing; Rao, Ting; Guan, Yong-Song

    2014-01-01

    Although colorectal cancer (CRC) has no longer been the leading cancer killer worldwide for years with the exponential development in computed tomography (CT) or magnetic resonance imaging, and positron emission tomography/CT as well as virtual colonoscopy for early detection, the CRC related mortality is still high. The objective of CRC screening is to reduce the burden of CRC and thereby the morbidity and mortality rates of the disease. It is believed that this goal can be achieved by regularly screening the average-risk population, enabling the detection of cancer at early, curable stages, and polyps before they become cancerous. Large-scale screening with multimodality imaging approaches plays an important role in reaching that goal to detect polyps, Crohn’s disease, ulcerative colitis and CRC in early stage. This article reviews kinds of presentative imaging procedures for various screening options and updates detecting, staging and re-staging of CRC patients for determining the optimal therapeutic method and forecasting the risk of CRC recurrence and the overall prognosis. The combination use of virtual colonoscopy and conventional endoscopy, advantages and limitations of these modalities are also discussed. PMID:25320519

  9. Radiology of colorectal cancer.

    PubMed

    Pijl, M E J; Chaoui, A S; Wahl, R L; van Oostayen, J A

    2002-05-01

    In the past 20 years, the radiology of colorectal cancer has evolved from the barium enema to advanced imaging modalities like phased array magnetic resonance imaging (MRI), virtual colonoscopy and positron emission tomography (PET). Nowadays, primary rectal cancers are preferably imaged with transrectal ultrasound or MRI, while barium enema is still the most often used technique for imaging of colonic cancers. Virtual colonoscopy is rapidly evolving and might considerably change the imaging of colorectal cancer in the near future. The use of virtual colonoscopy for screening purposes and imaging of the colon in occlusive cancer or incomplete colonoscopies is currently under evaluation. The main role of PET is in detecting tumour recurrences, both locally and distantly. Techniques to fuse cross-sectional anatomical (computer tomography (CT) and MRI) and functional (PET) images are being developed. Apart from diagnostic imaging, the radiologists has added image-guided minimally invasive treatments of colorectal liver metastases to their arsenal. The radio-frequency ablation technique is now widely available, and can be used during laparotomy or percutaneously in selected cases.

  10. Display modes for CT colonography. Part II. Blinded comparison of axial CT and virtual endoscopic and panoramic endoscopic volume-rendered studies.

    PubMed

    Beaulieu, C F; Jeffrey, R B; Karadi, C; Paik, D S; Napel, S

    1999-07-01

    To determine the sensitivity of radiologist observers for detecting colonic polyps by using three different data review (display) modes for computed tomographic (CT) colonography, or "virtual colonoscopy." CT colonographic data in a patient with a normal colon were used as base data for insertion of digitally synthesized polyps. Forty such polyps (3.5, 5, 7, and 10 mm in diameter) were randomly inserted in four copies of the base data. Axial CT studies, volume-rendered virtual endoscopic movies, and studies from a three-dimensional mode termed "panoramic endoscopy" were reviewed blindly and independently by two radiologists. Detection improved with increasing polyp size. Trends in sensitivity were dependent on whether all inserted lesions or only visible lesions were considered, because modes differed in how completely the colonic surface was depicted. For both reviewers and all polyps 7 mm or larger, panoramic endoscopy resulted in significantly greater sensitivity (90%) than did virtual endoscopy (68%, P = .014). For visible lesions only, the sensitivities were 85%, 81%, and 60% for one reader and 65%, 62%, and 28% for the other for virtual endoscopy, panoramic endoscopy, and axial CT, respectively. Three-dimensional displays were more sensitive than two-dimensional displays (P < .05). The sensitivity of panoramic endoscopy is higher than that of virtual endoscopy, because the former displays more of the colonic surface. Higher sensitivities for three-dimensional displays may justify the additional computation and review time.

  11. CT Colonography (Virtual Colonoscopy)

    MedlinePlus

    ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ... numerous x-ray beams and a set of electronic x-ray detectors rotate around you, measuring the ...

  12. Colorectal cancer screening with virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Ge, Yaorong; Vining, David J.; Ahn, David K.; Stelts, David R.

    1999-05-01

    Early detection and removal of colorectal polyps have been proven to reduce mortality from colorectal carcinoma (CRC), the second leading cause of cancer deaths in the United States. Unfortunately, traditional techniques for CRC examination (i.e., barium enema, sigmoidoscopy, and colonoscopy) are unsuitable for mass screening because of either low accuracy or poor public acceptance, costs, and risks. Virtual colonoscopy (VC) is a minimally invasive alternative that is based on tomographic scanning of the colon. After a patient's bowel is optimally cleansed and distended with gas, a fast tomographic scan, typically helical computed tomography (CT), of the abdomen is performed during a single breath-hold acquisition. Two-dimensional (2D) slices and three-dimensional (3D) rendered views of the colon lumen generated from the tomographic data are then examined for colorectal polyps. Recent clinical studies conducted at several institutions including ours have shown great potential for this technology to be an effective CRC screening tool. In this paper, we describe new methods to improve bowel preparation, colon lumen visualization, colon segmentation, and polyp detection. Our initial results show that VC with the new bowel preparation and imaging protocol is capable of achieving accuracy comparable to conventional colonoscopy and our new algorithms for image analysis contribute to increased accuracy and efficiency in VC examinations.

  13. MicroPET/CT Colonoscopy in long-lived Min mouse using NM404

    NASA Astrophysics Data System (ADS)

    Christensen, Matthew B.; Halberg, Richard B.; Schutten, Melissa M.; Weichert, Jamey P.

    2009-02-01

    Colon cancer is a leading cause of death in the US, even though many cases are preventable if tumors are detected early. One technique to promote screening is Computed Tomography Colonography (CTC). NM404 is a second generation phospholipid ether analogue which has demonstrated selective uptake and prolonged retention in 43/43 types of malignant tumors but not inflammatory sites or premalignant lesions. The purpose of this experiment was to evaluate (SWR x B6 )F1.Min mice as a preclinical model to test MicroPET/CT dual modality virtual colonoscopy. Each animal was given an IV injection of 124I-NM404 (100 uCi) 24, 48 and 96 hours prior to scanning on a dedicated microPET/CT system. Forty million counts were histogrammed in 3D and reconstructed using an OSEM 2D algorithm. Immediately after PET acquisition, a 93 m volumetric CT was acquired at 80 kVp, 800 uA and 350 ms exposures. Following CT, the mouse was sacrificed. The entire intestinal tract was excised, washed, insufflated, and scanned ex vivo A total of eight tissue samples from the small intestine were harvested: 5 were benign adenomas, 2 were malignant adenocarcinomas, and 1 was a Peyer's patch (lymph tissue) . The sites of these samples were positioned on CT and PET images based on morphological cues and the distance from the anus. Only 1/8 samples showed tracer uptake. several hot spots in the microPET image were not chosen for histology. (SWR x B6)F1.Min mice develop benign and malignant tumors, making this animal model a strong candidate for future dual modality microPET/CT virtual colonography studies.

  14. Detection of flat colorectal polyps at screening CT colonography in comparison with conventional polypoid lesions.

    PubMed

    Sakamoto, Takashi; Mitsuzaki, Katsuhiko; Utsunomiya, Daisuke; Matsuda, Katsuhiko; Yamamura, Sadahiro; Urata, Joji; Kawakami, Megumi; Yamashita, Yasuyuki

    2012-09-01

    Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. Detection sensitivity for flat polyps was 31.3%, 44.4%, and 87.5% for lesions measuring 2-3 mm, 4-5 mm, and ≥6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6%, 79.0%, and 91.7%. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.

  15. Colorectal Cancer

    MedlinePlus

    ... be detected by optical colonoscopy. Virtual colonoscopy uses virtual reality technology to produce three-dimensional images of the colon and rectum. However, the costs and benefits of virtual colonoscopy are still being investigated, and the technique ...

  16. Revisiting the potential signs of colorectal cancer on contrast-enhanced computed tomography without bowel preparation.

    PubMed

    Naqvi, Jawad; Hosmane, Sharath; Lapsia, Snehal

    2015-10-01

    Colorectal cancer (CRC) is the second most common cause of cancer death in the US. Earlier detection can allow treatment with curative intent and improve prognosis. Optical and virtual colonoscopy are widely used in screening for colonic polyps and in the investigation of suspected CRC. However, contrast-enhanced computed tomography (CT) is still performed to investigate various non-specific abdominal complaints. Hence, a significant number of CRC are identified on contrast-enhanced CT without bowel preparation. We describe several signs, which when present in tandem, raise suspicion of CRC, and may warrant further investigation with optical colonoscopy. These include an intraluminal mass, eccentric or circumferential wall thickening >3 mm, focal wall enhancement, pericolic fat stranding, a cluster of >3 local lymph nodes, and enlarged lymph nodes >10 mm in short axis. Multiplanar evaluation of the bowel should be performed on all CT abdominal studies, including those without bowel preparation, to identify subtle features of CRC.

  17. A feasibility study on laxative-free bowel preparation for virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Liang, Zhengrong; Chen, Dongqing; Wax, Mark; Lakare, Sarang; Li, Lihong; Anderson, Joseph; Kaufman, Arie; Harrington, Donald

    2005-04-01

    Objective: To investigate the feasibility of laxative-free bowel preparation to relieve the patient stress in colon cleansing for virtual colonoscopy. Materials and Methods: Three different bowel-preparation protocols were investigated by 60 study cases from 35 healthy male volunteers. All the protocols utilize low-residue diet for two days and differ in diet for the third day - the day just prior to image acquisition in the fourth day morning. Protocol Diet-1 utilizes fluid or liquid diet in the third day, Diet-2 utilizes a food kit, and Diet-3 remains the low-residue diet. Oral contrast of barium sulfate (2.1%, 250 ml) was added respectively to the dinner in the second day and the three meals in the third day. Two doses of MD-Gastroview (60 ml) were ingested each in the evening of the third day and in the morning before image acquisition. Images were acquired by a single-slice detector spiral CT (computed tomography) scanner with 5 mm collimation, 1 mm reconstruction, 1.5-2.0:1.0 pitch, 100-150 mA, and 120 kVp after the colons were inflated by CO2. The contrasted colonic residue materials were electronically removed from the CT images by specialized computer-segmentation algorithms. Results: By assumptions that the healthy young volunteers have no polyp and the image resolution is approximately 4 mm, a successful electronic cleansing is defined as "no more than five false positives and no removal of a colon fold part greater than 4 mm" for each study case. The successful rate is 100% for protocol Diet-1, 77% for Diet-2 and 57% for Diet-3. Conclusion: A laxative-free bowel preparation is feasible for virtual colonoscopy.

  18. Simulation-Based Training for Colonoscopy

    PubMed Central

    Preisler, Louise; Svendsen, Morten Bo Søndergaard; Nerup, Nikolaj; Svendsen, Lars Bo; Konge, Lars

    2015-01-01

    Abstract The aim of this study was to create simulation-based tests with credible pass/fail standards for 2 different fidelities of colonoscopy models. Only competent practitioners should perform colonoscopy. Reliable and valid simulation-based tests could be used to establish basic competency in colonoscopy before practicing on patients. Twenty-five physicians (10 consultants with endoscopic experience and 15 fellows with very little endoscopic experience) were tested on 2 different simulator models: a virtual-reality simulator and a physical model. Tests were repeated twice on each simulator model. Metrics with discriminatory ability were identified for both modalities and reliability was determined. The contrasting-groups method was used to create pass/fail standards and the consequences of these were explored. The consultants significantly performed faster and scored higher than the fellows on both the models (P < 0.001). Reliability analysis showed Cronbach α = 0.80 and 0.87 for the virtual-reality and the physical model, respectively. The established pass/fail standards failed one of the consultants (virtual-reality simulator) and allowed one fellow to pass (physical model). The 2 tested simulations-based modalities provided reliable and valid assessments of competence in colonoscopy and credible pass/fail standards were established for both the tests. We propose to use these standards in simulation-based training programs before proceeding to supervised training on patients. PMID:25634177

  19. Colonoscopy procedure simulation: virtual reality training based on a real time computational approach.

    PubMed

    Wen, Tingxi; Medveczky, David; Wu, Jackie; Wu, Jianhuang

    2018-01-25

    Colonoscopy plays an important role in the clinical screening and management of colorectal cancer. The traditional 'see one, do one, teach one' training style for such invasive procedure is resource intensive and ineffective. Given that colonoscopy is difficult, and time-consuming to master, the use of virtual reality simulators to train gastroenterologists in colonoscopy operations offers a promising alternative. In this paper, a realistic and real-time interactive simulator for training colonoscopy procedure is presented, which can even include polypectomy simulation. Our approach models the colonoscopy as thick flexible elastic rods with different resolutions which are dynamically adaptive to the curvature of the colon. More material characteristics of this deformable material are integrated into our discrete model to realistically simulate the behavior of the colonoscope. We present a simulator for training colonoscopy procedure. In addition, we propose a set of key aspects of our simulator that give fast, high fidelity feedback to trainees. We also conducted an initial validation of this colonoscopic simulator to determine its clinical utility and efficacy.

  20. Prospective Trial Evaluating the Surgical Anastomosis at One-Year Colorectal Cancer Surveillance: CT Colonography Versus Optical Colonoscopy and Implications for Patient Care.

    PubMed

    Pickhardt, Perry J; Edwards, Kristin; Bruining, David H; Gollub, Marc; Kupfer, Sonja; Lubner, Sam J; Kim, David H; Ross, Eric; Keenan, Eileen; Weinberg, David S

    2017-11-01

    The aim of this study was to compare the accuracy of CT colonography versus optical colonoscopy for neoplastic involvement at the surgical anastomosis 1 year after curative-intent colorectal cancer resection. Two hundred one patients (mean age, 58.6 years; 117 men, 84 women) underwent same-day contrast-enhanced CT colonography and colonoscopy approximately 1 year (mean, 12.1 months; median, 11.9 months) after colorectal cancer resection as part of a prospective, multicenter trial. All patients enrolled were without clinical evidence of disease and considered low risk for recurrence (stage I-III). Suspected neoplastic lesions within 5 cm of the colonic anastomosis were recorded at CT colonography, with subsequent colonoscopy performed for the same, with segmental unblinding of colonography findings. Anastomotic region biopsy or polypectomy was performed at the endoscopist's discretion. None of the 201 patients had intraluminal anastomotic cancer recurrence or advanced neoplasia (or metachronous cancers). CT colonography detected extramural perianastomotic recurrence in 2 patients (1.0%); neither was detected at colonoscopy. Only 2 patients (1.0%; 2/201) were called positive at CT colonography for intraluminal anastomotic nondiminutive lesions (7- to 8-mm polyps), which were confirmed at colonoscopy but nonneoplastic at histopathology. At optical colonoscopy, the anastomosis was deemed abnormal and/or biopsied in 10.0% (20/201), yielding only 1 nondiminutive benign neoplasm (7-mm tubular adenoma). The lack of luminal cancer recurrence in our lower-risk cohort precludes assessment of sensitivity for detection, rendering the study underpowered in this regard. Potential cost savings of combined CT/CT colonography over the standard CT/colonoscopy approach were not assessed. Relevant intraluminal anastomotic pathology appears to be very uncommon 1 year after colorectal cancer resection in lower-risk cohorts. Unlike colonoscopy, diagnostic contrast-enhanced CT colonography effectively evaluates both the intra- and extraluminal aspects of the anastomosis. See Video Abstract at http://links.lww.com/DCR/A471.

  1. Texture-based CAD improves diagnosis for low-dose CT colonography

    NASA Astrophysics Data System (ADS)

    Liang, Zhengrong; Cohen, Harris; Posniak, Erica; Fiore, Eddie; Wang, Zigang; Li, Bin; Andersen, Joseph; Harrington, Donald

    2008-03-01

    Computed tomography (CT)-based virtual colonoscopy or CT colonography (CTC) currently utilizes oral contrast solutions to tag the colonic fluid and possibly residual stool for differentiation from the colon wall and polyps. The enhanced image density of the tagged colonic materials causes a significant partial volume (PV) effect into the colon wall as well as the lumen space (filled with air or CO II). The PV effect on the colon wall can "bury" polyps of size as large as 5mm by increasing their image densities to a noticeable level, resulting in false negatives. It can also create false positives when PV effect goes into the lumen space. We have been modeling the PV effect for mixture-based image segmentation and developing text-based computer-aided detection of polyp (CADpolyp) by utilizing the PV mixture-based image segmentation. This work presents some preliminary results of developing and applying texture-based CADpolyp technique to low-dose CTC studies. A total of 114 studies of asymptomatic patients older than 50, who underwent CTC and then optical colonoscopy (OC) on the same day, were selected from a database, which was accumulated in the past decade and contains various bowel preparations and CT scanning protocols. The participating radiologists found ten polyps of greater than 5 mm from a total of 16 OC proved polyps, i.e., a detection sensitivity of 63%. They scored 23 false positives from the database, i.e., a 20% false positive rate. Approximately 70% of the datasets were marked as imperfect bowel cleansing and/or presence of image artifacts. The impact of imperfect bowel cleansing and image artifacts on VC performance is significant. The texture-based CADpolyp detected all the polyps with an average of 2.68 false positives per patient. This indicates that texture-based CADpolyp can improve the CTC performance in the cases of imperfect cleansed bowels and presence of image artifacts.

  2. Colorectal Cancer: Cost-effectiveness of Colonoscopy versus CT Colonography Screening with Participation Rates and Costs.

    PubMed

    van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; Goede, S Lucas; Kuipers, Ernst J; Dekker, Evelien; Stoker, Jaap; van Ballegooijen, Marjolein

    2018-06-01

    Purpose To compare the cost-effectiveness of computed tomographic (CT) colonography and colonoscopy screening by using data on unit costs and participation rates from a randomized controlled screening trial in a dedicated screening setting. Materials and Methods Observed participation rates and screening costs from the Colonoscopy or Colonography for Screening, or COCOS, trial were used in a microsimulation model to estimate costs and quality-adjusted life-years (QALYs) gained with colonoscopy and CT colonography screening. For both tests, the authors determined optimal age range and screening interval combinations assuming a 100% participation rate. Assuming observed participation for these combinations, the cost-effectiveness of both tests was compared. Extracolonic findings were not included because long-term follow-up data are lacking. Results The participation rates for colonoscopy and CT colonography were 21.5% (1276 of 5924 invitees) and 33.6% (982 of 2920 invitees), respectively. Colonoscopy was more cost-effective in the screening strategies with one or two lifetime screenings, whereas CT colonography was more cost-effective in strategies with more lifetime screenings. CT colonography was the preferred test for willingness-to-pay-thresholds of €3200 per QALY gained and higher, which is lower than the Dutch willingness-to-pay threshold of €20 000. With equal participation, colonoscopy was the preferred test independent of willingness-to-pay thresholds. The findings were robust for most of the sensitivity analyses, except with regard to relative screening costs and subsequent participation. Conclusion Because of the higher participation rates, CT colonography screening for colorectal cancer is more cost-effective than colonoscopy screening. The implementation of CT colonography screening requires previous satisfactory resolution to the question as to how best to deal with extracolonic findings. © RSNA, 2018 Online supplemental material is available for this article.

  3. Colonoscopic Findings in Patients With Incidental Colonic Focal FDG Uptake.

    PubMed

    Keyzer, Caroline; Dhaene, Benjamin; Blocklet, Didier; De Maertelaer, Viviane; Goldman, Serge; Gevenois, Pierre Alain

    2015-05-01

    The purpose of this study was to investigate the nature of FDG-avid and non-FDG-avid lesions detected at colonoscopy in patients presenting with incidental focal colonic FDG uptake at PET/CT. Among 9073 patients who underwent PET/CT over a 4-year period, 82 patients without a history of colonic disease had focal colonic FDG uptake and underwent colonoscopy. In consensus, a radiologist and a nuclear physician read images from these PET/CT examinations. They recorded the location of focal FDG uptake in the colon and associated CT abnormalities and measured maximum standardized uptake value (SUVmax) and metabolic volume (MV). Readings were performed twice--first without and second with knowledge of lesion location at colonoscopy. The final diagnosis was based on colonoscopic findings and histopathologic results categorized into benign, premalignant, or malignant. One hundred seven foci of colonic FDG uptake at PET/CT and 150 lesions at colonoscopy were detected. Among 107 foci of FDG uptake, 65 (61%) corresponded to a lesion at colonoscopy (true-positive findings), and 42 (39%) did not (false-positive findings). Among 150 lesions found at colonoscopy, 85 (57%) were not FDG avid (false-negative findings). The MV of true-positive findings was lower than that of false-positive findings (4.0 ± 0.4 cm(3) vs 6.2 ± 0.7 cm(3); p = 0.006), but SUVmax did not differ (7.4 ± 0.5 vs 7.7 ± 0.5; p = 0.649). Considering the histopathologic categories of the lesions and the false-positive findings, there was no difference in SUVmax (p = 0.103), but MV was lower in premalignant lesions than in false-positive findings (p = 0.005). Focal colonic FDG uptake may indicate the presence of a benign, pre-malignant, or malignant lesion. Subsequent colonoscopy should not be restricted to the colonic site of FDG uptake.

  4. Automated virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Hunt, Gordon W.; Hemler, Paul F.; Vining, David J.

    1997-05-01

    Virtual colonscopy (VC) is a minimally invasive alternative to conventional fiberoptic endoscopy for colorectal cancer screening. The VC technique involves bowel cleansing, gas distension of the colon, spiral computed tomography (CT) scanning of a patient's abdomen and pelvis, and visual analysis of multiplanar 2D and 3D images created from the spiral CT data. Despite the ability of interactive computer graphics to assist a physician in visualizing 3D models of the colon, a correct diagnosis hinges upon a physician's ability to properly identify small and sometimes subtle polyps or masses within hundreds of multiplanar and 3D images. Human visual analysis is time-consuming, tedious, and often prone to error of interpretation.We have addressed the problem of visual analysis by creating a software system that automatically highlights potential lesions in the 2D and 3D images in order to expedite a physician's interpretation of the colon data.

  5. Incidental detection of colorectal lesions by FDG PET/CT scans in melanoma patients.

    PubMed

    Young, Christopher J; Zahid, Assad; Choy, Ian; Thompson, John F; Saw, Robyn P M

    2017-11-01

    Increased use of PET/CT scans in oncology patients has raised detection of Colorectal incidentalomas (CIs). The frequency and diagnostic outcomes of identifying these lesions in melanoma patients have not previously been studied. This studies primary objective was to determine the prevalence of CIs found on PET/CT scans in melanoma patients. The secondary objectives were to correlate the PET/CT findings with the pathology found at colonoscopy, and identify which patients were referred for colonoscopy. A retrospective analysis of patients identified from the prospectively collected research database of Melanoma Institute Australia. 2509 patients with melanoma underwent PET/CT scans between 2001 and 2013. The prevalence of CIs, the correlation of lesions, and the survival of patients who underwent colonoscopy versus patients who did not were analyzed. The prevalence of CIs in melanoma patients who had PET/CT scans was 3.2%. Forty-five of the 81 (56%) patients with CIs underwent colonoscopy. Of these, premalignant or malignant disease was found in 58%. Patients with previous metastatic melanoma were significantly less likely to be referred for colonoscopy. Patients undergoing colonoscopy had significantly better survival, as did those without previous distant metastases before the CIs were found, and those without any metastases at the time the CIs were found. These factors were not significant on multivariate analysis. The prevalence of incidental colorectal lesions identified on PET/CT scans in melanoma patients was found to be equivalent to that in the general cancer population. Patients undergoing colonoscopy had better survival than those who did not. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  6. Two methods of Haustral fold detection from computed tomographic virtual colonoscopy images

    NASA Astrophysics Data System (ADS)

    Chowdhury, Ananda S.; Tan, Sovira; Yao, Jianhua; Linguraru, Marius G.; Summers, Ronald M.

    2009-02-01

    Virtual colonoscopy (VC) has gained popularity as a new colon diagnostic method over the last decade. VC is a new, less invasive alternative to the usually practiced optical colonoscopy for colorectal polyp and cancer screening, the second major cause of cancer related deaths in industrial nations. Haustral (colonic) folds serve as important landmarks for virtual endoscopic navigation in the existing computer-aided-diagnosis (CAD) system. In this paper, we propose and compare two different methods of haustral fold detection from volumetric computed tomographic virtual colonoscopy images. The colon lumen is segmented from the input using modified region growing and fuzzy connectedness. The first method for fold detection uses a level set that evolves on a mesh representation of the colon surface. The colon surface is obtained from the segmented colon lumen using the Marching Cubes algorithm. The second method for fold detection, based on a combination of heat diffusion and fuzzy c-means algorithm, is employed on the segmented colon volume. Folds obtained on the colon volume using this method are then transferred to the corresponding colon surface. After experimentation with different datasets, results are found to be promising. The results also demonstrate that the first method has a tendency of slight under-segmentation while the second method tends to slightly over-segment the folds.

  7. Efficient seeding and defragmentation of curvature streamlines for colonic polyp detection

    NASA Astrophysics Data System (ADS)

    Zhao, Lingxiao; Botha, Charl P.; Truyen, Roel; Vos, Frans M.; Post, Frits H.

    2008-03-01

    Many computer aided diagnosis (CAD) schemes have been developed for colon cancer detection using Virtual Colonoscopy (VC). In earlier work, we developed an automatic polyp detection method integrating flow visualization techniques, that forms part of the CAD functionality of an existing Virtual Colonoscopy pipeline. Curvature streamlines were used to characterize polyp surface shape. Features derived from curvature streamlines correlated highly with true polyp detections. During testing with a large number of patient data sets, we found that the correlation between streamline features and true polyps could be affected by noise and our streamline generation technique. The seeding and spacing constraints and CT noise could lead to streamline fragmentation, which reduced the discriminating power of our streamline features. In this paper, we present two major improvements of our curvature streamline generation. First, we adapted our streamline seeding strategy to the local surface properties and made the streamline generation faster. It generates a significantly smaller number of seeds but still results in a comparable and suitable streamline distribution. Second, based on our observation that longer streamlines are better surface shape descriptors, we improved our streamline tracing algorithm to produce longer streamlines. Our improved techniques are more effcient and also guide the streamline geometry to correspond better to colonic surface shape. These two adaptations support a robust and high correlation between our streamline features and true positive detections and lead to better polyp detection results.

  8. Virtually assisted optical colonoscopy

    NASA Astrophysics Data System (ADS)

    Marino, Joseph; Qiu, Feng; Kaufman, Arie

    2008-03-01

    We present a set of tools used to enhance the optical colonoscopy procedure in a novel manner with the aim of improving both the accuracy and efficiency of this procedure. In order to better present the colon information to the gastroenterologist performing a conventional (optical) colonoscopy, we undistort the radial distortion of the fisheye view of the colonoscope. The radial distortion is modeled with a function that converts the fisheye view to the perspective view, where the shape and size of polyps can be more readily observed. The conversion, accelerated on the graphics processing unit and running in real-time, calculates the corresponding position in the fisheye view of each pixel on the perspective image. We also merge our previous work in computer-aided polyp detection for virtual colonoscopy into the optical colonoscopy environment. The physical colonoscope path in the optical colonoscopy is approximated with the hugging corner shortest path, which is correlated with the centerline in the virtual colonoscopy. With the estimated distance that the colonoscope has been inserted, we are able to provide the gastroenterologist with visual cues along the observation path as to the location of possible polyps found by the detection process. In order to present the information to the gastroenterologist in a non-intrusive manner, we have developed a friendly user interface to enhance the optical colonoscopy without being cumbersome, distracting, or resulting in a more lackadaisical inspection by the gastroenterologist.

  9. Accurate motion parameter estimation for colonoscopy tracking using a regression method

    NASA Astrophysics Data System (ADS)

    Liu, Jianfei; Subramanian, Kalpathi R.; Yoo, Terry S.

    2010-03-01

    Co-located optical and virtual colonoscopy images have the potential to provide important clinical information during routine colonoscopy procedures. In our earlier work, we presented an optical flow based algorithm to compute egomotion from live colonoscopy video, permitting navigation and visualization of the corresponding patient anatomy. In the original algorithm, motion parameters were estimated using the traditional Least Sum of squares(LS) procedure which can be unstable in the context of optical flow vectors with large errors. In the improved algorithm, we use the Least Median of Squares (LMS) method, a robust regression method for motion parameter estimation. Using the LMS method, we iteratively analyze and converge toward the main distribution of the flow vectors, while disregarding outliers. We show through three experiments the improvement in tracking results obtained using the LMS method, in comparison to the LS estimator. The first experiment demonstrates better spatial accuracy in positioning the virtual camera in the sigmoid colon. The second and third experiments demonstrate the robustness of this estimator, resulting in longer tracked sequences: from 300 to 1310 in the ascending colon, and 410 to 1316 in the transverse colon.

  10. Colon cancer screening

    MedlinePlus

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  11. The development of a virtual reality training curriculum for colonoscopy.

    PubMed

    Sugden, Colin; Aggarwal, Rajesh; Banerjee, Amrita; Haycock, Adam; Thomas-Gibson, Siwan; Williams, Christopher B; Darzi, Ara

    2012-07-01

    The development of a structured virtual reality (VR) training curriculum for colonoscopy using high-fidelity simulation. Colonoscopy requires detailed knowledge and technical skill. Changes to working practices in recent times have reduced the availability of traditional training opportunities. Much might, therefore, be achieved by applying novel technologies such as VR simulation to colonoscopy. Scientifically developed device-specific curricula aim to maximize the yield of laboratory-based training by focusing on validated modules and linking progression to the attainment of benchmarked proficiency criteria. Fifty participants comprised of 30 novices (<10 colonoscopies), 10 intermediates (100 to 500 colonoscopies), and 10 experienced (>500 colonoscopies) colonoscopists were recruited to participate. Surrogates of proficiency, such as number of procedures undertaken, determined prospective allocation to 1 of 3 groups (novice, intermediate, and experienced). Construct validity and learning value (comparison between groups and within groups respectively) for each task and metric on the chosen simulator model determined suitability for inclusion in the curriculum. Eight tasks in possession of construct validity and significant learning curves were included in the curriculum: 3 abstract tasks, 4 part-procedural tasks, and 1 procedural task. The whole-procedure task was valid for 11 metrics including the following: "time taken to complete the task" (1238, 343, and 293 s; P < 0.001) and "insertion length with embedded tip" (23.8, 3.6, and 4.9 cm; P = 0.005). Learning curves consistently plateaued at or beyond the ninth attempt. Valid metrics were used to define benchmarks, derived from the performance of the experienced cohort, for each included task. A comprehensive, stratified, benchmarked, whole-procedure curriculum has been developed for a modern high-fidelity VR colonoscopy simulator.

  12. Retention of colonoscopy skills after virtual reality simulator training by independent and proctored methods.

    PubMed

    Snyder, Christopher W; Vandromme, Marianne J; Tyra, Sharon L; Hawn, Mary T

    2010-07-01

    Virtual reality (VR) simulators may enhance surgical resident colonoscopy skills, but the duration of skill retention and the effects of different simulator training methods are unknown. Medical students participating in a randomized trial of independent (automated simulator feedback only) versus proctored (human expert feedback plus simulator feedback) simulator training performed a standardized VR colonoscopy scenario at baseline, at the end of training (posttraining), and after a median 4.5 months without practice (retention). Performances were scored on a 10-point scale based on expert proficiency criteria and compared for the independent and proctored groups. Thirteen trainees (8 proctored, 5 independent) were included. Performance at retention testing was significantly better than baseline (median score 10 vs. 5, P < 0.0001), and no different from posttraining (median score 10 vs. 10, P = 0.19). Score changes from baseline to retention and from posttraining to retention were no different for the proctored and independent groups. Overinsufflation and excessive force were the most common reasons for nonproficiency at retention. After proficiency-based VR simulator training, colonoscopy skills are retained for several months, regardless of whether an independent or proctored approach is used. Error avoidance skills may not be retained as well as speed and efficiency skills.

  13. Simulation-Based Training of Non-Technical Skills in Colonoscopy: Protocol for a Randomized Controlled Trial.

    PubMed

    Khan, Rishad; Scaffidi, Michael A; Walsh, Catharine M; Lin, Peter; Al-Mazroui, Ahmed; Chana, Barinder; Kalaichandran, Ruben; Lee, Woojin; Grantcharov, Teodor P; Grover, Samir C

    2017-08-04

    Non-technical skills (NTS), such as communication and professionalism, contribute to the safe and effective completion of procedures. NTS training has previously been shown to improve surgical performance. Moreover, increases in NTS have been associated with improved clinical endoscopic performance. Despite this evidence, NTS training has not been tested as an intervention in endoscopy. The aim of this study is to evaluate the effectiveness of a simulation-based training (SBT) curriculum of NTS on novice endoscopists' performance of clinical colonoscopy. Novice endoscopists were randomized to 2 groups. The control group received 4 hours of interactive didactic sessions on colonoscopy theory and 6 hours of SBT. Hours 5 and 6 of the SBT were integrated scenarios, wherein participants interacted with a standardized patient and nurse, while performing a colonoscopy on the virtual reality (VR) simulator. The NTS (intervention) group received the same teaching sessions but the last hour was focused on NTS teaching. The NTS group also reviewed a checklist of tasks relevant to NTS concepts prior to each integrated scenario case and was provided with dedicated feedback on their NTS performance during the integrated scenario practice. All participants were assessed at baseline, immediately after training, and 4 to 6 weeks post-training. The primary outcome measure is colonoscopy-specific performance in the clinical setting. In total, 42 novice endoscopists completed the study. Data collection and analysis is ongoing. We anticipate completion of all assessments by August 2017. Data analysis, manuscript writing, and subsequent submission for publication is expected to be completed by December 2017. Results from this study may inform the implementation of NTS training into postgraduate gastrointestinal curricula. NTS curricula may improve attitudes towards patient safety and self-reflection among trainees. Moreover, enhanced NTS may lead to superior clinical performance and outcomes in colonoscopy. Clinicaltrial.gov NCT02877420; https://www.clinicaltrials.gov/ct2/show/NCT02877420 (Archived by WebCite at http://www.webcitation.org/6rw94ubXX NCT02877420). ©Rishad Khan, Michael A Scaffidi, Catharine M Walsh, Peter Lin, Ahmed Al-Mazroui, Barinder Chana, Ruben Kalaichandran, Woojin Lee, Teodor P Grantcharov, Samir C Grover. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 04.08.2017.

  14. The impact of constructive feedback on training in gastrointestinal endoscopy using high-fidelity Virtual-Reality simulation: a randomised controlled trial.

    PubMed

    Kruglikova, Irina; Grantcharov, Teodor P; Drewes, Asbjorn M; Funch-Jensen, Peter

    2010-02-01

    Recently, virtual reality computer simulators have been used to enhance traditional endoscopy teaching. Previous studies have demonstrated construct validity of these systems and transfer of virtual skills to the operating room. However, to date no simulator-training curricula have been designed and there is very little evidence on the impact of external feedback on acquisition of endoscopic skills. The aim of the present study was to assess the impact of external feedback on the learning curves on a VR colonoscopy simulator using inexperienced trainees. 22 trainees, without colonoscopy experience were randomised to a group which received structured feedback provided by an experienced supervisor and a controlled group. All participants performed 15 repetitions of task 3 from the Introduction colonoscopy module of the Accu Touch Endoscopy simulator. Retention/transfer tests on simulator were performed 4-6 weeks after the last repetition. The proficiency levels were based on the performance of eight experienced colonoscopists. All subjects were able to complete the procedure on the simulator. There were no perforations in the feedback group versus seven in the non-feedback group. Subjects in the feedback group reached expert proficiency levels in percentage of mucosa visualised and time to reach the caecum significantly faster compared with the control group. None of the groups demonstrated significant degradation of performance in simulator retention/transfer tests. Concurrent feedback given by supervisor concur an advantage in acquisition of basic colonoscopy skills and achieving of proficiency level as compared to independent training.

  15. Towards designing an optical-flow based colonoscopy tracking algorithm: a comparative study

    NASA Astrophysics Data System (ADS)

    Liu, Jianfei; Subramanian, Kalpathi R.; Yoo, Terry S.

    2013-03-01

    Automatic co-alignment of optical and virtual colonoscopy images can supplement traditional endoscopic procedures, by providing more complete information of clinical value to the gastroenterologist. In this work, we present a comparative analysis of our optical flow based technique for colonoscopy tracking, in relation to current state of the art methods, in terms of tracking accuracy, system stability, and computational efficiency. Our optical-flow based colonoscopy tracking algorithm starts with computing multi-scale dense and sparse optical flow fields to measure image displacements. Camera motion parameters are then determined from optical flow fields by employing a Focus of Expansion (FOE) constrained egomotion estimation scheme. We analyze the design choices involved in the three major components of our algorithm: dense optical flow, sparse optical flow, and egomotion estimation. Brox's optical flow method,1 due to its high accuracy, was used to compare and evaluate our multi-scale dense optical flow scheme. SIFT6 and Harris-affine features7 were used to assess the accuracy of the multi-scale sparse optical flow, because of their wide use in tracking applications; the FOE-constrained egomotion estimation was compared with collinear,2 image deformation10 and image derivative4 based egomotion estimation methods, to understand the stability of our tracking system. Two virtual colonoscopy (VC) image sequences were used in the study, since the exact camera parameters(for each frame) were known; dense optical flow results indicated that Brox's method was superior to multi-scale dense optical flow in estimating camera rotational velocities, but the final tracking errors were comparable, viz., 6mm vs. 8mm after the VC camera traveled 110mm. Our approach was computationally more efficient, averaging 7.2 sec. vs. 38 sec. per frame. SIFT and Harris affine features resulted in tracking errors of up to 70mm, while our sparse optical flow error was 6mm. The comparison among egomotion estimation algorithms showed that our FOE-constrained egomotion estimation method achieved the optimal balance between tracking accuracy and robustness. The comparative study demonstrated that our optical-flow based colonoscopy tracking algorithm maintains good accuracy and stability for routine use in clinical practice.

  16. Colorectal Cancer Screening

    MedlinePlus

    ... blood test Sigmoidoscopy Colonoscopy Virtual colonoscopy DNA stool test Studies have shown that screening for colorectal cancer using ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ...

  17. Risks of Colorectal Cancer Screening

    MedlinePlus

    ... blood test Sigmoidoscopy Colonoscopy Virtual colonoscopy DNA stool test Studies have shown that screening for colorectal cancer using ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ...

  18. Endoscopic and histopathological analysis of incidental focal colorectal 18 F-fluorodeoxyglucose uptake in PET/CT scan: Colonoscopic evaluation is warranted.

    PubMed

    Valente, Michael A

    2018-03-01

    Unexpected focal colorectal 18  F-fluorodeoxyglucose uptake has become a common clinical dilemma. The aim of this study was to identify the clinical significance of incidentally detected colorectal lesions on PET/CT scans by comparing positive PET/CT findings with endoscopic and histopathological analysis. A retrospective analysis of a colonoscopy database was reviewed. All patients that underwent colonoscopy secondary to focal incidental uptake on PET/CT were evaluated. PET/CT findings were correlated with endoscopic and histopathological results. 84 patients underwent colonoscopy secondary to incidental focal colorectal uptake on PET/CT. A total of 63 patients had an endoscopic and histological confirmation of the area of abnormality, for a positive predictive value of 75%. Newly diagnosed colorectal carcinoma was discovered in 13 patients (15.4%) and forty-four patients (52.3%) were discovered to have a premalignant lesion. Incidental focal colorectal uptake of 18  F-fluorodeoxyglucose is associated with a substantial risk of underlying neoplastic colorectal lesions. Early identification of these lesions may alter patient management and treatment plans. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Colorectal Cancer Screening (PDQ®)—Patient Version

    Cancer.gov

    There are five types of tests that are used to screen for colorectal cancer: fecal occult blood test, sigmoidoscopy, colonoscopy, virtual colonoscopy, and DNA stool test. Learn more about these and other tests in this expert-reviewed summary.

  20. Prevalence of colorectal cancer in acute uncomplicated diverticulitis and the role of the interval colonoscopy.

    PubMed

    Soh, Nicholas Yock Teck; Chia, Daryl Kai Ann; Teo, Nan Zun; Ong, Calvin Jian Ming; Wijaya, Ramesh

    2018-04-16

    Although computed tomography (CT) is the imaging modality of choice for diagnosing colonic diverticulitis today, there remains a risk of colorectal cancer mimicking diverticulitis due to overlapping imaging features. Current practice guidelines recommend interval colonoscopy after diverticulitis to exclude occult malignancy. Some authors have suggested that this may be unnecessary in patients with uncomplicated diverticulitis. The aim of our study was to examine the prevalence of occult colorectal cancer in patients with CT-proven acute uncomplicated diverticulitis in an Asian population. This was a retrospective study of all patients admitted for CT-proven acute uncomplicated diverticulitis between 2007 and 2011 in a single institution. Colonoscopy and histopathology reports were reviewed for patients who underwent interval colonic evaluation. For patients who defaulted follow-up, national health records were reviewed for any subsequent diagnoses of colorectal cancer. The primary outcome was prevalence of colorectal cancer in the cohort. Secondary outcome was prevalence of advanced adenomas. A total of 227 patients with acute uncomplicated diverticulitis were included in our study. One hundred and thirty-five patients (59.5%) underwent follow-up colonic evaluation. The overall prevalence of colorectal cancer was 1.8%, with half these patients presenting with acute colonic obstruction after defaulting follow-up evaluation. Of the patients, 1.5% who underwent colonoscopy had advanced adenomas. Prevalence of colorectal cancer in patients with CT-proven acute uncomplicated diverticulitis may not be as low as previously suggested. We recommend that patients with acute uncomplicated diverticulitis continue to be offered interval colonoscopy until larger studies demonstrate the safety of omission.

  1. Virtual colonoscopy, optical colonoscopy, or fecal occult blood testing for colorectal cancer screening: results of a pilot randomized controlled trial.

    PubMed

    You, John J; Liu, Yudong; Kirby, John; Vora, Parag; Moayyedi, Paul

    2015-07-09

    No head-to-head randomized controlled trials have demonstrated the superiority of one colorectal screening modality over another in reducing colorectal cancer mortality. We conducted a pilot randomized controlled trial of fecal occult blood testing (FOBT), optical colonoscopy (OC), and virtual colonoscopy (VC), to inform the planning of a larger evaluative trial. Eligible patients (aged 50 to 70) were recruited from five primary care practices in Hamilton, ON, Canada, between March 23, 2010 and August 11, 2010, and randomized 1:1:1 in a parallel design using an automated, centralized telephone service to either FOBT, OC, or VC. To reflect conventional practice, patients received no additional reminders to complete their allocated screening test beyond those received in usual practice. The primary outcome was completion of the assigned screening procedure. Results of the index test and any follow-up investigations were ascertained at 6 months. Participants, caregivers, and outcome assessors were not blinded to group assignment. The trial was stopped early due to lack of ongoing funding. A total of 198 participants were enrolled, of whom 67 were allocated to FOBT, 66 to OC, and 65 to VC. The allocated screening procedure was completed by 43 (64%) subjects allocated to FOBT (95% confidence interval [CI], 52-75%), 53 (80%) subjects allocated to OC (95% CI, 69-88%), and 50 (77%) subjects allocated to VC (95% CI, 65-85%); because the trial stopped early, we had insufficient statistical power to detect clinically relevant differences in completion rates. During 6 months follow-up, colorectal adenomas were detected in 0 (0%) subjects allocated to FOBT, 12 (18%) subjects allocated to OC, and 2 (3%) subjects allocated to VC. One subject in the OC arm had histological evidence of high-grade dysplasia. No subjects were diagnosed with colorectal cancer. In this pilot randomized controlled trial of colorectal cancer screening in a primary care setting, 64-80% of subjects completed their allocated screening test. These findings may be of value to investigators planning clinical trials to evaluate the effectiveness of colorectal cancer screening. ClinicalTrials.gov NCT00865527. https://clinicaltrials.gov/ct2/show/NCT00865527.

  2. Impact of a simulation training curriculum on technical and nontechnical skills in colonoscopy: a randomized trial.

    PubMed

    Grover, Samir C; Garg, Ankit; Scaffidi, Michael A; Yu, Jeffrey J; Plener, Ian S; Yong, Elaine; Cino, Maria; Grantcharov, Teodor P; Walsh, Catharine M

    2015-12-01

    GI endoscopy simulation-based training augments early clinical performance; however, the optimal manner by which to deliver training is unknown. We aimed to validate a simulation-based structured comprehensive curriculum (SCC) designed to teach technical, cognitive, and integrative competencies in colonoscopy. Single-blinded, randomized, controlled trial. Endoscopic simulation course at an academic hospital. Thirty-three novice endoscopists were allocated to an SCC group or self-regulated learning (SRL) group. The SCC group received a curriculum consisting of 6 hours of didactic lectures and 8 hours of virtual reality simulation-based training with expert feedback. The SRL group was provided a list of desired objectives and was instructed to practice on the simulator for an equivalent time (8 hours). Clinical transfer was assessed during 2 patient colonoscopies using the Joint Advisory Group Direct Observation of Procedural Skills (JAG DOPS) scale. Secondary outcome measures included differences in procedural knowledge, immediate post-training simulation performance, and delayed post-training (4-6 weeks) performance during an integrated scenario test on the JAG DOPS communication and integrated scenario global rating scales. There was no significant difference in baseline or post-training performance on the simulator task. The SCC group performed superiorly during their first and second clinical colonoscopies. Additionally, the SCC group demonstrated significantly better knowledge and colonoscopy-specific performance, communication, and global performance during the integrated scenario. We were unable to measure SRL participants' effort outside of mandatory training. In addition, feedback metrics and number of available simulation cases are limited. These results support integration of endoscopy simulation into a structured curriculum incorporating instructional feedback and complementary didactic knowledge as a means to augment technical, cognitive, and integrative skills acquisition, as compared with SRL on virtual reality simulators. ( NCT01991522.) Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  3. The influence of rifaximin on diverticulitis rate and quality of life in patients with diverticulosis.

    PubMed

    Banasiewicz, Tomasz; Francuzik, Wojciech; Bobkiewicz, Adam; Krokowicz, Łukasz; Borejsza-Wysocki, Maciej; Paszkowski, Jacek; Studniarek, Adam; Krokowicz, Piotr; Grochowalski, Marcin; Szczepkowski, Marek; Lorenc, Zbigniew

    2017-02-28

    Diverticulosis, its associated symptoms and complications are one of the most common pathologies of the gastrointestinal tract in more economically developed countries. Presence of diverticuli and their clinical consequences can be divided into four categories: 1) diverticulosis, i.e. an asymptomatic presence of diverticuli that are usually found by accident 2) symptomatic uncomplicated diverticulosis 3) diverticulitis (acute uncomplicated diverticulitis) 4) complications of diverticulitis (conditions requiring hospital stay). The aim of this study was to retrospectively analyze the efficacy of rifaximin in preventing diverticulitis in patients visiting proctology clinics. The diagnostic criterium for diverticulosis was confirmation by colonoscopy, barium enema or CT colography (virtual colonoscopy) as well as history of at least one documented episode of diverticulosis. History of diverticulosis was evaluated based on medical records, clinical symptoms, elevated level of CRP (>5.0) and/or diagnostic imaging (ultrasound, CT). After setting strict exclusion criteria, 248 patients were qualified for the study out of 686, and they were later divided into two groups: control group (group I - 145 patients) and studied group (group II - 103 patients receiving rifaximin prophylaxis). Diverticulitis rate was comparable in both groups over a period of 6 months before study (p = 0.1306) and 6 months of treatment (p=0.3044). Between the 6th and 12th month of treatment, a significantly lower rate of diverticulitis was noted in the group receiving rifaximin compared to control group (p<0.0001). Patients receiving rifaximin reported higher quality of life (which was assessed using the VAS scale) compared to control group after 12 months. The results confirmed the efficacy of riaximin in prevention of diverticulitis, even in the scheme of repeated courses every 3 months. Not only did application of rifaximin lower the rate of diverticulitis and its complications in patients after an episode of diverticulitis, but also it improved the patients' quality of life. It seems that diverticulitis prophylaxis based on rifaximin can be economically efficient, however, it requires further research.

  4. Routine colonic endoscopic evaluation following resolution of acute diverticulitis: Is it necessary?

    PubMed Central

    Agarwal, Amit K; Karanjawala, Burzeen E; Maykel, Justin A; Johnson, Eric K; Steele, Scott R

    2014-01-01

    Diverticular disease incidence is increasing up to 65% by age 85 in industrialized nations, low fiber diets, and in younger and obese patients. Twenty-five percent of patients with diverticulosis will develop acute diverticulitis. This imposes a significant burden on healthcare systems, resulting in greater than 300000 admissions per year with an estimated annual cost of $3 billion USD. Abdominal computed tomography (CT) is the diagnostic study of choice, with a sensitivity and specificity greater than 95%. Unfortunately, similar CT findings can be present in colonic neoplasia, especially when perforated or inflamed. This prompted professional societies such as the American Society of Colon Rectal Surgeons to recommend patients undergo routine colonoscopy after an episode of acute diverticulitis to rule out malignancy. Yet, the data supporting routine colonoscopy after acute diverticulitis is sparse and based small cohort studies utilizing outdated technology. While any patient with an indication for a colonoscopy should undergo appropriate endoscopic evaluation, in the era of widespread use of high-resolution computed tomography, routine colonic endoscopic evaluation following resolution of acute uncomplicated diverticulitis poses additional costs, comes with inherent risks, and may require further study. In this manuscript, we review the current data related to this recommendation. PMID:25253951

  5. Multicenter, randomized, controlled trial of virtual-reality simulator training in acquisition of competency in colonoscopy.

    PubMed

    Cohen, Jonathan; Cohen, Seth A; Vora, Kinjal C; Xue, Xiaonan; Burdick, J Steven; Bank, Simmy; Bini, Edmund J; Bodenheimer, Henry; Cerulli, Maurice; Gerdes, Hans; Greenwald, David; Gress, Frank; Grosman, Irwin; Hawes, Robert; Mullin, Gerard; Mullen, Gerard; Schnoll-Sussman, Felice; Starpoli, Anthony; Stevens, Peter; Tenner, Scott; Villanueva, Gerald

    2006-09-01

    The GI Mentor is a virtual reality simulator that uses force feedback technology to create a realistic training experience. To define the benefit of training on the GI Mentor on competency acquisition in colonoscopy. Randomized, controlled, blinded, multicenter trial. Academic medical centers with accredited gastroenterology training programs. First-year GI fellows. Subjects were randomized to receive 10 hours of unsupervised training on the GI Mentor or no simulator experience during the first 8 weeks of fellowship. After this period, both groups began performing real colonoscopies. The first 200 colonoscopies performed by each fellow were graded by proctors to measure technical and cognitive success, and patient comfort level during the procedure. A mixed-effects model comparison between the 2 groups of objective and subjective competency scores and patient discomfort in the performance of real colonoscopies over time. Forty-five fellows were randomized from 16 hospitals over 2 years. Fellows in the simulator group had significantly higher objective competency rates during the first 100 cases. A mixed-effects model demonstrated a higher objective competence overall in the simulator group (P < .0001), with the difference between groups being significantly greater during the first 80 cases performed. The median number of cases needed to reach 90% competency was 160 in both groups. The patient comfort level was similar. Fellows who underwent GI Mentor training performed significantly better during the early phase of real colonoscopy training.

  6. Successful Endoscopic Submucosal Dissection of a Large Terminal Ileal Lipoma

    PubMed Central

    Noda, Hisatsugu; Ogasawara, Naotaka; Tamura, Yasuhiro; Kondo, Yoshihiro; Izawa, Shinya; Ebi, Masahide; Funaki, Yasushi; Sasaki, Makoto; Kasugai, Kunio

    2016-01-01

    A 78-year-old woman who had recurrent right lower abdominal pain for about 1 year underwent computed tomography (CT) because of a follow-up observation 1 year after right breast cancer surgery. CT revealed a tumor in the colon. The patient was referred to our hospital for detailed examinations. An abdominal CT showed a low-density tumor of approximately 30 mm in the ascending colon, and the CT density inside the tumor was same as that of fatty tissues. A subsequent colonoscopy showed a submucosal tumor (SMT) in the proximal ascending colon developing from the terminal ileum. A colonoscopic ultrasonography revealed that the SMT was a high-echoic mass mainly localized in the submucosal layer. Based on the findings from CT, colonoscopy, and colonoscopic ultrasonography, the SMT was diagnosed as a pedunculated lipoma originating from the terminal ileum and treated with endoscopic submucosal dissection (ESD) because of recurrent abdominal pain. The 40-mm tumor was resected en bloc without complications. ESD may be more appropriate than polypectomy and surgery for removal of small intestinal tumors, because ESD allows direct visualization of the cutting line and exactly dissects the submucosal layers without damaging the muscular layers. ESD is a potentially useful treatment to remove intestinal lipomas. PMID:27843426

  7. A virtual reality endoscopic simulator augments general surgery resident cancer education as measured by performance improvement.

    PubMed

    White, Ian; Buchberg, Brian; Tsikitis, V Liana; Herzig, Daniel O; Vetto, John T; Lu, Kim C

    2014-06-01

    Colorectal cancer is the second most common cause of death in the USA. The need for screening colonoscopies, and thus adequately trained endoscopists, particularly in rural areas, is on the rise. Recent increases in required endoscopic cases for surgical resident graduation by the Surgery Residency Review Committee (RRC) further emphasize the need for more effective endoscopic training during residency to determine if a virtual reality colonoscopy simulator enhances surgical resident endoscopic education by detecting improvement in colonoscopy skills before and after 6 weeks of formal clinical endoscopic training. We conducted a retrospective review of prospectively collected surgery resident data on an endoscopy simulator. Residents performed four different clinical scenarios on the endoscopic simulator before and after a 6-week endoscopic training course. Data were collected over a 5-year period from 94 different residents performing a total of 795 colonoscopic simulation scenarios. Main outcome measures included time to cecal intubation, "red out" time, and severity of simulated patient discomfort (mild, moderate, severe, extreme) during colonoscopy scenarios. Average time to intubation of the cecum was 6.8 min for those residents who had not undergone endoscopic training versus 4.4 min for those who had undergone endoscopic training (p < 0.001). Residents who could be compared against themselves (pre vs. post-training), cecal intubation times decreased from 7.1 to 4.3 min (p < 0.001). Post-endoscopy rotation residents caused less severe discomfort during simulated colonoscopy than pre-endoscopy rotation residents (4 vs. 10%; p = 0.004). Virtual reality endoscopic simulation is an effective tool for both augmenting surgical resident endoscopy cancer education and measuring improvement in resident performance after formal clinical endoscopic training.

  8. A Randomized Trial Comparing High Definition Colonoscopy Alone With High Definition Dye Spraying and Electronic Virtual Chromoendoscopy for Detection of Colonic Neoplastic Lesions During IBD Surveillance Colonoscopy.

    PubMed

    Iacucci, Marietta; Kaplan, Gilaad G; Panaccione, Remo; Akinola, Oluseyi; Lethebe, Brendan Cord; Lowerison, Mark; Leung, Yvette; Novak, Kerri L; Seow, Cynthia H; Urbanski, Stefan; Minoo, Parham; Gui, Xianyong; Ghosh, Subrata

    2018-02-01

    Dye spraying chromoendoscopy (DCE) is recommended for the detection of colonic neoplastic lesions in inflammatory bowel disease (IBD). The majority of neoplastic lesions are visible endoscopically and therefore targeted biopsies are appropriate for surveillance colonoscopy. To compare three different techniques for surveillance colonoscopy to detect colonic neoplastic lesions in IBD patients: high definition (HD), (DCE), or virtual chromoendoscopy (VCE) using iSCAN image enhanced colonoscopy. A randomized non-inferiority trial was conducted to determine the detection rates of neoplastic lesions in IBD patients with longstanding colitis. Patients with inactive disease were enrolled into three arms of the study. Endoscopic neoplastic lesions were classified by the Paris classification and Kudo pit pattern, then histologically classified by the Vienna classification. A total of 270 patients (55% men; age range 20-77 years, median age 49 years) were assessed by HD (n=90), VCE (n=90), or DCE (n=90). Neoplastic lesion detection rates in the VCE arm was non-inferior to the DCE arm. HD was non-inferior to either DCE or VCE for detection of all neoplastic lesions. In the lesions detected, location at right colon and the Kudo pit pattern were predictive of neoplastic lesions (OR 6.52 (1.98-22.5 and OR 21.50 (8.65-60.10), respectively). In this randomized trial, VCE or HD-WLE is not inferior to dye spraying colonoscopy for detection of colonic neoplastic lesions during surveillance colonoscopy. In fact, in this study HD-WLE alone was sufficient for detection of dysplasia, adenocarcinoma or all neoplastic lesions.

  9. Techniques for virtual lung nodule insertion: volumetric and morphometric comparison of projection-based and image-based methods for quantitative CT

    NASA Astrophysics Data System (ADS)

    Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Sedlmair, Martin; Choudhury, Kingshuk Roy; Pezeshk, Aria; Sahiner, Berkman; Samei, Ehsan

    2017-09-01

    Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual lung nodules into CT images. Assessment was done by comparing virtual nodule volume and shape to the CT-derived volume and shape of synthetic nodules. 24 synthetic nodules (three sizes, four morphologies, two repeats) were physically inserted into the lung cavity of an anthropomorphic chest phantom (KYOTO KAGAKU). The phantom was imaged with and without nodules on a commercial CT scanner (SOMATOM Definition Flash, Siemens) using a standard thoracic CT protocol at two dose levels (1.4 and 22 mGy CTDIvol). Raw projection data were saved and reconstructed with filtered back-projection and sinogram affirmed iterative reconstruction (SAFIRE, strength 5) at 0.6 mm slice thickness. Corresponding 3D idealized, virtual nodule models were co-registered with the CT images to determine each nodule’s location and orientation. Virtual nodules were voxelized, partial volume corrected, and inserted into nodule-free CT data (accounting for system imaging physics) using two methods: projection-based Technique A, and image-based Technique B. Also a third Technique C based on cropping a region of interest from the acquired image of the real nodule and blending it into the nodule-free image was tested. Nodule volumes were measured using a commercial segmentation tool (iNtuition, TeraRecon, Inc.) and deformation was assessed using the Hausdorff distance. Nodule volumes and deformations were compared between the idealized, CT-derived and virtual nodules using a linear mixed effects regression model which utilized the mean, standard deviation, and coefficient of variation (Mea{{n}RHD} , ST{{D}RHD} and C{{V}RHD}{) }~ of the regional Hausdorff distance. Overall, there was a close concordance between the volumes of the CT-derived and virtual nodules. Percent differences between them were less than 3% for all insertion techniques and were not statistically significant in most cases. Correlation coefficient values were greater than 0.97. The deformation according to the Hausdorff distance was also similar between the CT-derived and virtual nodules with minimal statistical significance in the (C{{V}RHD} ) for Techniques A, B, and C. This study shows that both projection-based and image-based nodule insertion techniques yield realistic nodule renderings with statistical similarity to the synthetic nodules with respect to nodule volume and deformation. These techniques could be used to create a database of hybrid CT images containing nodules of known size, location and morphology.

  10. Techniques for virtual lung nodule insertion: volumetric and morphometric comparison of projection-based and image-based methods for quantitative CT

    PubMed Central

    Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Sedlmair, Martin; Choudhury, Kingshuk Roy; Pezeshk, Aria; Sahiner, Berkman; Samei, Ehsan

    2017-01-01

    Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual lung nodules into CT images. Assessment was done by comparing virtual nodule volume and shape to the CT-derived volume and shape of synthetic nodules. 24 synthetic nodules (three sizes, four morphologies, two repeats) were physically inserted into the lung cavity of an anthropomorphic chest phantom (KYOTO KAGAKU). The phantom was imaged with and without nodules on a commercial CT scanner (SOMATOM Definition Flash, Siemens) using a standard thoracic CT protocol at two dose levels (1.4 and 22 mGy CTDIvol). Raw projection data were saved and reconstructed with filtered back-projection and sinogram affirmed iterative reconstruction (SAFIRE, strength 5) at 0.6 mm slice thickness. Corresponding 3D idealized, virtual nodule models were co-registered with the CT images to determine each nodule’s location and orientation. Virtual nodules were voxelized, partial volume corrected, and inserted into nodule-free CT data (accounting for system imaging physics) using two methods: projection-based Technique A, and image-based Technique B. Also a third Technique C based on cropping a region of interest from the acquired image of the real nodule and blending it into the nodule-free image was tested. Nodule volumes were measured using a commercial segmentation tool (iNtuition, TeraRecon, Inc.) and deformation was assessed using the Hausdorff distance. Nodule volumes and deformations were compared between the idealized, CT-derived and virtual nodules using a linear mixed effects regression model which utilized the mean, standard deviation, and coefficient of variation (MeanRHD, and STDRHD CVRHD) of the regional Hausdorff distance. Overall, there was a close concordance between the volumes of the CT-derived and virtual nodules. Percent differences between them were less than 3% for all insertion techniques and were not statistically significant in most cases. Correlation coefficient values were greater than 0.97. The deformation according to the Hausdorff distance was also similar between the CT-derived and virtual nodules with minimal statistical significance in the (CVRHD) for Techniques A, B, and C. This study shows that both projection-based and image-based nodule insertion techniques yield realistic nodule renderings with statistical similarity to the synthetic nodules with respect to nodule volume and deformation. These techniques could be used to create a database of hybrid CT images containing nodules of known size, location and morphology. PMID:28786399

  11. Mixed virtual reality simulation--taking endoscopic simulation one step further.

    PubMed

    Courteille, O; Felländer-Tsai, L; Hedman, L; Kjellin, A; Enochsson, L; Lindgren, G; Fors, U

    2011-01-01

    This pilot study aimed to assess medical students' appraisals of a "mixed" virtual reality simulation for endoscopic surgery (with a virtual patient case in addition to a virtual colonoscopy) as well as the impact of this simulation set-up on students' performance. Findings indicate that virtual patients can enhance contextualization of simulated endoscopy and thus facilitate an authentic learning environment, which is important in order to increase motivation.

  12. Image fusion in craniofacial virtual reality modeling based on CT and 3dMD photogrammetry.

    PubMed

    Xin, Pengfei; Yu, Hongbo; Cheng, Huanchong; Shen, Shunyao; Shen, Steve G F

    2013-09-01

    The aim of this study was to demonstrate the feasibility of building a craniofacial virtual reality model by image fusion of 3-dimensional (3D) CT models and 3 dMD stereophotogrammetric facial surface. A CT scan and stereophotography were performed. The 3D CT models were reconstructed by Materialise Mimics software, and the stereophotogrammetric facial surface was reconstructed by 3 dMD patient software. All 3D CT models were exported as Stereo Lithography file format, and the 3 dMD model was exported as Virtual Reality Modeling Language file format. Image registration and fusion were performed in Mimics software. Genetic algorithm was used for precise image fusion alignment with minimum error. The 3D CT models and the 3 dMD stereophotogrammetric facial surface were finally merged into a single file and displayed using Deep Exploration software. Errors between the CT soft tissue model and 3 dMD facial surface were also analyzed. Virtual model based on CT-3 dMD image fusion clearly showed the photorealistic face and bone structures. Image registration errors in virtual face are mainly located in bilateral cheeks and eyeballs, and the errors are more than 1.5 mm. However, the image fusion of whole point cloud sets of CT and 3 dMD is acceptable with a minimum error that is less than 1 mm. The ease of use and high reliability of CT-3 dMD image fusion allows the 3D virtual head to be an accurate, realistic, and widespread tool, and has a great benefit to virtual face model.

  13. Detection of incidental colorectal pathology on positron emission tomography/computed tomography.

    PubMed

    Mui, Milton; Akhurst, Timothy; Warrier, Satish K; Lynch, A Craig; Heriot, Alexander G

    2018-03-01

    Positron emission tomography/computed tomography (PET/CT) is an important modality in cancer imaging. With its increasing availability and use, it is not uncommon to detect incidental focal colorectal 18 F-FDG uptake which poses a diagnostic challenge, as they may be associated with malignant or pre-malignant colorectal lesions. The aim of our study is to determine the proportion of these findings which represents true pathology. Patients with incidental focal colorectal 18 F-FDG uptake on PET/CT who subsequently underwent colonoscopy between January 2002 to September 2013 were identified from a prospective database in a tertiary referral centre. PET/CT results were correlated with colonoscopy and pathology results in these patients. Positive predictive values (PPVs) and 95% confidence intervals (CIs) of PET/CT in the detection of incidental colorectal pathology were calculated. A total of 148 patients (92 men and 56 women), with a mean age 73 years (range of 36 to 93 years) were included in the study. A total of 170 foci of colorectal 18 F-FDG uptake were detected on PET/CT. Of these, 101 foci corresponded to a malignant or pre-malignant lesion (PPV 59%; 95% CI: 52-67%). On a per-patient analysis, 93 patients had at least one focus of colorectal 18 F-FDG uptake which corresponded to a pre-malignant or malignant lesion (PPV 63%; 95% CI: 54-71%). Focal colorectal 18 F-FDG uptake on PET/CT is associated with a significant proportion of malignant or pre-malignant lesions. Further evaluation with colonoscopy is recommended. © 2016 Royal Australasian College of Surgeons.

  14. Splitting a colon geometry with multiplanar clipping

    NASA Astrophysics Data System (ADS)

    Ahn, David K.; Vining, David J.; Ge, Yaorong; Stelts, David R.

    1998-06-01

    Virtual colonoscopy, a recent three-dimensional (3D) visualization technique, has provided radiologists with a unique diagnostic tool. Using this technique, a radiologist can examine the internal morphology of a patient's colon by navigating through a surface-rendered model that is constructed from helical computed tomography image data. Virtual colonoscopy can be used to detect early forms of colon cancer in a way that is less invasive and expensive compared to conventional endoscopy. However, the common approach of 'flying' through the colon lumen to visually search for polyps is tedious and time-consuming, especially when a radiologist loses his or her orientation within the colon. Furthermore, a radiologist's field of view is often limited by the 3D camera position located inside the colon lumen. We have developed a new technique, called multi-planar geometry clipping, that addresses these problems. Our algorithm divides a complex colon anatomy into several smaller segments, and then splits each of these segments in half for display on a static medium. Multi-planar geometry clipping eliminates virtual colonoscopy's dependence upon expensive, real-time graphics workstations by enabling radiologists to globally inspect the entire internal surface of the colon from a single viewpoint.

  15. Crohn's Disease

    MedlinePlus

    ... causes, such as infection. You may also undergo flexible sigmoidoscopy, colonoscopy, body CT, body MRI, MR enterography, upper GI, small ... Flexible sigmoidoscopy , performed by inserting a sigmoidoscope (a flexible tube ... can also sometimes be seen. Body CT scan , a special type of x-ray ...

  16. Preoperative Diagnosis and Surgical Approach of Appendiceal Mucinous Cystadenoma: Usefulness of Volcano Sign.

    PubMed

    Shiihara, Masahiro; Ohki, Takeshi; Yamamoto, Masakazu

    2017-01-01

    We report a case of appendiceal mucinous cystadenoma that was successfully diagnosed preoperatively and treated by laparoscopic resection. We could find volcano sign on colonoscopy and cystic lesion without any nodules at the appendix on computed tomography (CT). Without any malignant factors in preoperative examinations, we performed laparoscopic appendectomy including the cecal wall. We could avoid performing excessive operation for cystadenoma with accurate preoperative diagnosis and intraoperative finding and pathological diagnosis during surgery. Appendiceal mucocele is a rare disease that is divided into 3 pathological types: hyperplasia, cystadenoma, and cystadenocarcinoma. The surgical approaches for it remain controversial and oversurgery is sometimes done for benign tumor, because preoperative diagnosis is difficult and rupturing an appendiceal tumor results in dissemination. Based on our study, volcano sign on colonoscopy and CT findings were important for the preoperative diagnosis of appendiceal mucocele. Furthermore, we think that laparoscopic resection will become a surgical option for the treatment of appendiceal mucocele.

  17. Comparative economic evaluation of data from the ACRIN National CT Colonography Trial with three cancer intervention and surveillance modeling network microsimulations.

    PubMed

    Vanness, David J; Knudsen, Amy B; Lansdorp-Vogelaar, Iris; Rutter, Carolyn M; Gareen, Ilana F; Herman, Benjamin A; Kuntz, Karen M; Zauber, Ann G; van Ballegooijen, Marjolein; Feuer, Eric J; Chen, Mei-Hsiu; Johnson, C Daniel

    2011-11-01

    To estimate the cost-effectiveness of computed tomographic (CT) colonography for colorectal cancer (CRC) screening in average-risk asymptomatic subjects in the United States aged 50 years. Enrollees in the American College of Radiology Imaging Network National CT Colonography Trial provided informed consent, and approval was obtained from the institutional review board at each site. CT colonography performance estimates from the trial were incorporated into three Cancer Intervention and Surveillance Modeling Network CRC microsimulations. Simulated survival and lifetime costs for screening 50-year-old subjects in the United States with CT colonography every 5 or 10 years were compared with those for guideline-concordant screening with colonoscopy, flexible sigmoidoscopy plus either sensitive unrehydrated fecal occult blood testing (FOBT) or fecal immunochemical testing (FIT), and no screening. Perfect and reduced screening adherence scenarios were considered. Incremental cost-effectiveness and net health benefits were estimated from the U.S. health care sector perspective, assuming a 3% discount rate. CT colonography at 5- and 10-year screening intervals was more costly and less effective than FOBT plus flexible sigmoidoscopy in all three models in both 100% and 50% adherence scenarios. Colonoscopy also was more costly and less effective than FOBT plus flexible sigmoidoscopy, except in the CRC-SPIN model assuming 100% adherence (incremental cost-effectiveness ratio: $26,300 per life-year gained). CT colonography at 5- and 10-year screening intervals and colonoscopy were net beneficial compared with no screening in all model scenarios. The 5-year screening interval was net beneficial over the 10-year interval except in the MISCAN model when assuming 100% adherence and willingness to pay $50,000 per life-year gained. All three models predict CT colonography to be more costly and less effective than non-CT colonographic screening but net beneficial compared with no screening given model assumptions. RSNA, 2011

  18. Accuracy of Dual-Energy Virtual Monochromatic CT Numbers: Comparison between the Single-Source Projection-Based and Dual-Source Image-Based Methods.

    PubMed

    Ueguchi, Takashi; Ogihara, Ryota; Yamada, Sachiko

    2018-03-21

    To investigate the accuracy of dual-energy virtual monochromatic computed tomography (CT) numbers obtained by two typical hardware and software implementations: the single-source projection-based method and the dual-source image-based method. A phantom with different tissue equivalent inserts was scanned with both single-source and dual-source scanners. A fast kVp-switching feature was used on the single-source scanner, whereas a tin filter was used on the dual-source scanner. Virtual monochromatic CT images of the phantom at energy levels of 60, 100, and 140 keV were obtained by both projection-based (on the single-source scanner) and image-based (on the dual-source scanner) methods. The accuracy of virtual monochromatic CT numbers for all inserts was assessed by comparing measured values to their corresponding true values. Linear regression analysis was performed to evaluate the dependency of measured CT numbers on tissue attenuation, method, and their interaction. Root mean square values of systematic error over all inserts at 60, 100, and 140 keV were approximately 53, 21, and 29 Hounsfield unit (HU) with the single-source projection-based method, and 46, 7, and 6 HU with the dual-source image-based method, respectively. Linear regression analysis revealed that the interaction between the attenuation and the method had a statistically significant effect on the measured CT numbers at 100 and 140 keV. There were attenuation-, method-, and energy level-dependent systematic errors in the measured virtual monochromatic CT numbers. CT number reproducibility was comparable between the two scanners, and CT numbers had better accuracy with the dual-source image-based method at 100 and 140 keV. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  19. Technical Note: Quantitative accuracy evaluation for spectral images from a detector-based spectral CT scanner using an iodine phantom.

    PubMed

    Duan, Xinhui; Arbique, Gary; Guild, Jeffrey; Xi, Yin; Anderson, Jon

    2018-05-01

    The purpose of this study was to evaluate the quantitative accuracy of spectral images from a detector-based spectral CT scanner using a phantom with iodine-loaded inserts. A 40-cm long-body phantom with seven iodine inserts (2-20 mg/ml of iodine) was used in the study. The inserts could be placed at 5.5 or 10.5 cm from the phantom axis. The phantom was scanned five times for each insert configuration using 120 kVp tube voltage. A set of iodine, virtual noncontrast, effective atomic number, and virtual monoenergetic spectral CT images were generated and measurements were made for all the iodine rods. Measured values were compared with reference values calculated from the chemical composition information provided by the phantom manufacturer. Radiation dose from the spectral CT was compared to a conventional CT using a CTDI (32 cm) phantom. Good agreement between measurements and reference values was achieved for all types of spectral images. The differences ranged from -0.46 to 0.1 mg/ml for iodine concentration, -9.95 to 6.41 HU for virtual noncontrast images, 0.12 to 0.35 for effective Z images, and -17.7 to 55.7 HU for virtual monoenergetic images. For a similar CTDIvol, image noise from the conventional CT was 10% lower than the spectral CT. The detector-based spectral CT can achieve accurate spectral measurements on iodine concentration, virtual non-contrast images, effective atomic numbers, and virtual monoenergetic images. © 2018 American Association of Physicists in Medicine.

  20. Screening CT Colonography: Multicenter Survey of Patient Experience, Preference, and Potential Impact on Adherence

    PubMed Central

    Pooler, B. Dustin; Baumel, Mark J.; Cash, Brooks D.; Moawad, Fouad J.; Riddle, Mark S.; Patrick, Amy M.; Damiano, Mark; Lee, Matthew H.; Kim, David H.; del Rio, Alejandro Muñoz; Pickhardt, Perry J.

    2013-01-01

    OBJECTIVE Prior research indicates CT colonography (CTC) would be a cost-effective colorectal cancer (CRC) screening test if widespread availability were to increase overall CRC screening adherence rates. The primary aims of this multicenter study were to evaluate patient experience and satisfaction with CTC screening and compare preference against screening colonoscopy. MATERIALS AND METHODS A 12-question survey instrument measuring pretest choice, experience, and satisfaction was given to a consecutive cohort of adults undergoing CTC screening in three disparate screening settings: university academic center, military medical center, and community practice. The study cohort was composed of individuals voluntarily participating in clinical CTC screening programs. RESULTS A total of 1417 patients responded to the survey. The top reasons for choosing CTC for screening included “noninvasiveness” (68.0%), “avoidance of sedation/anesthesia” (63.1%), “ability to drive after the test” (49.2%), “avoidance of optical colonoscopy risks” (46.9%), and “identifying abnormalities outside the colon” (43.3%). Only 7.2% of patients reported pain during the CTC examination and only 2.5% reported greater than moderate discomfort. Of 441 patients who had experienced both CTC and optical colonoscopy, 77.1% preferred CTC and 13.8% preferred optical colonoscopy. Of all patients, 29.6% indicated that they may not have undergone optical colonoscopy screening if CTC were not available. Of all patients, 92.9% labeled their overall experience with CTC as “excellent” or “good,” and 93.0% indicated they would choose CTC for their next screening. CONCLUSION Respondents reported a very high satisfaction level with CTC, and those who had experienced both modalities indicated a preference for CTC over optical colonoscopy. These results suggest that CTC has the potential to increase adherence to CRC screening guidelines if widely available. PMID:22623549

  1. Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry.

    PubMed

    Bostani, Maryam; Mueller, Jonathon W; McMillan, Kyle; Cody, Dianna D; Cagnon, Chris H; DeMarco, John J; McNitt-Gray, Michael F

    2015-02-01

    The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for all exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. The calculated mean percent difference between TLD measurements and Monte Carlo simulations was -4.9% with standard deviation of 8.7% and a range of -22.7% to 5.7%. The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Z; Greskovich, J; Xia, P

    Purpose: To generate virtual phantoms with clinically relevant deformation and use them to objectively evaluate geometric and dosimetric uncertainties of deformable image registration (DIR) algorithms. Methods: Ten lung cancer patients undergoing adaptive 3DCRT planning were selected. For each patient, a pair of planning CT (pCT) and replanning CT (rCT) were used as the basis for virtual phantom generation. Manually adjusted meshes were created for selected ROIs (e.g. PTV, lungs, spinal cord, esophagus, and heart) on pCT and rCT. The mesh vertices were input into a thin-plate spline algorithm to generate a reference displacement vector field (DVF). The reference DVF wasmore » used to deform pCT to generate a simulated replanning CT (srCT) that was closely matched to rCT. Three DIR algorithms (Demons, B-Spline, and intensity-based) were applied to these ten virtual phantoms. The images, ROIs, and doses were mapped from pCT to srCT using the DVFs computed by these three DIRs and compared to those mapped using the reference DVF. Results: The average Dice coefficients for selected ROIs were from 0.85 to 0.96 for Demons, from 0.86 to 0.97 for intensity-based, and from 0.76 to 0.95 for B-Spline. The average Hausdorff distances for selected ROIs were from 2.2 to 5.4 mm for Demons, from 2.3 to 6.8 mm for intensity-based, and from 2.4 to 11.4 mm for B-Spline. The average absolute dose errors for selected ROIs were from 0.2 to 0.6 Gy for Demons, from 0.1 to 0.5 Gy for intensity-based, and from 0.5 to 1.5 Gy for B-Spline. Conclusion: Virtual phantoms were modeled after patients with lung cancer and were clinically relevant for adaptive radiotherapy treatment replanning. Virtual phantoms with known DVFs serve as references and can provide a fair comparison when evaluating different DIRs. Demons and intensity-based DIRs were shown to have smaller geometric and dosimetric uncertainties than B-Spline. Z Shen: None; K Bzdusek: an employee of Philips Healthcare; J Greskovich: None; P Xia: received research grants from Philips Healthcare and Siemens Healthcare.« less

  3. Functional evaluation of the endotics system, a new disposable self-propelled robotic colonoscope: in vitro tests and clinical trial.

    PubMed

    Cosentino, Felice; Tumino, Emanuele; Passoni, Giovanni Rubis; Morandi, Elisabetta; Capria, Alfonso

    2009-08-01

    Currently, the best method for CRC screening is colonoscopy, which ideally (where possible) is performed under partial or deep sedation. This study aims to evaluate the efficacy of the Endotics System, a new robotic device composed of a workstation and a disposable probe, in performing accurate and well-tolerated colonoscopies. This new system could also be considered a precursor of other innovating vectors for atraumatic locomotion through natural orifices such as the bowel. The flexible probe adapts its shape to the complex contours of the colon, thereby exerting low strenuous forces during its movement. These novel characteristics allow for a painless and safe colonoscopy, thus eliminating all major associated risks such as infection, cardiopulmonary complications and colon perforation. An experimental study was devised to investigate stress pattern differences between traditional and robotic colonoscopy, in which 40 enrolled patients underwent both robotic and standard colonoscopy within the same day. The stress pattern related to robotic colonoscopy was 90% lower than that of standard colonoscopy. Additionally, the robotic colonoscopy demonstrated a higher diagnostic accuracy, since, due to the lower insufflation rate, it was able to visualize small polyps and angiodysplasias not seen during the standard colonoscopy. All patients rated the robotic colonoscopy as virtually painless compared to the standard colonoscopy, ranking pain and discomfort as 0.9 and 1.1 respectively, on a scale of O to 10, versus 6.9 and 6.8 respectively for the standard device. The new Endotics System demonstrates efficacy in the diagnosis of colonic pathologies using a procedure nearly completely devoid of pain. Therefore, this system can also be looked upon as the first step toward developing and implementing colonoscopy with atraumatic locomotion through the bowel while maintaining a high level of diagnostic accuracy;

  4. At what costs will screening with CT colonography be competitive? A cost-effectiveness approach.

    PubMed

    Lansdorp-Vogelaar, Iris; van Ballegooijen, Marjolein; Zauber, Ann G; Boer, Rob; Wilschut, Janneke; Habbema, J Dik F

    2009-03-01

    The costs of computed tomographic colonography (CTC) are not yet established for screening use. In our study, we estimated the threshold costs for which CTC screening would be a cost-effective alternative to colonoscopy for colorectal cancer (CRC) screening in the general population. We used the MISCAN-colon microsimulation model to estimate the costs and life-years gained of screening persons aged 50-80 years for 4 screening strategies: (i) optical colonoscopy; and CTC with referral to optical colonoscopy of (ii) any suspected polyp; (iii) a suspected polyp >or=6 mm and (iv) a suspected polyp >or=10 mm. For each of the 4 strategies, screen intervals of 5, 10, 15 and 20 years were considered. Subsequently, for each CTC strategy and interval, the threshold costs of CTC were calculated. We performed a sensitivity analysis to assess the effect of uncertain model parameters on the threshold costs. With equal costs ($662), optical colonoscopy dominated CTC screening. For CTC to gain similar life-years as colonoscopy screening every 10 years, it should be offered every 5 years with referral of polyps >or=6 mm. For this strategy to be as cost-effective as colonoscopy screening, the costs must not exceed $285 or 43% of colonoscopy costs (range in sensitivity analysis: 39-47%). With 25% higher adherence than colonoscopy, CTC threshold costs could be 71% of colonoscopy costs. Our estimate of 43% is considerably lower than previous estimates in literature, because previous studies only compared CTC screening to 10-yearly colonoscopy, where we compared to different intervals of colonoscopy screening.

  5. Colovesical fistula causing an uncommon reason for failure of computed tomography colonography: a case report.

    PubMed

    Neroladaki, Angeliki; Breguet, Romain; Botsikas, Diomidis; Terraz, Sylvain; Becker, Christoph D; Montet, Xavier

    2012-07-23

    Computed tomography colonography, or virtual colonoscopy, is a good alternative to optical colonoscopy. However, suboptimal patient preparation or colon distension may reduce the diagnostic accuracy of this imaging technique. We report the case of an 83-year-old Caucasian woman who presented with a five-month history of pneumaturia and fecaluria and an acute episode of macrohematuria, leading to a high clinical suspicion of a colovesical fistula. The fistula was confirmed by standard contrast-enhanced computed tomography. Optical colonoscopy was performed to exclude the presence of an underlying colonic neoplasm. Since optical colonoscopy was incomplete, computed tomography colonography was performed, but also failed due to inadequate colon distension. The insufflated air directly accumulated within the bladder via the large fistula. Clinicians should consider colovesical fistula as a potential reason for computed tomography colonography failure.

  6. ACR Appropriateness Criteria® Colorectal Cancer Screening.

    PubMed

    Moreno, Courtney; Kim, David H; Bartel, Twyla B; Cash, Brooks D; Chang, Kevin J; Feig, Barry W; Fowler, Kathryn J; Garcia, Evelyn M; Kambadakone, Avinash R; Lambert, Drew L; Levy, Angela D; Marin, Daniele; Peterson, Christine M; Scheirey, Christopher D; Smith, Martin P; Weinstein, Stefanie; Carucci, Laura R

    2018-05-01

    This review summarizes the relevant literature regarding colorectal screening with imaging. For individuals at average or moderate risk for colorectal cancer, CT colonography is usually appropriate for colorectal cancer screening. After positive results on a fecal occult blood test or immunohistochemical test, CT colonography is usually appropriate for colorectal cancer detection. For individuals at high risk for colorectal cancer (eg, hereditary nonpolyposis colorectal cancer, ulcerative colitis, or Crohn colitis), optical colonoscopy is preferred because of its ability to obtain biopsies to detect dysplasia. After incomplete colonoscopy, CT colonography is usually appropriate for colorectal cancer screening for individuals at average, moderate, or high risk. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Development and comparison of projection and image space 3D nodule insertion techniques

    NASA Astrophysics Data System (ADS)

    Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Samei, Ehsan

    2016-04-01

    This study aimed to develop and compare two methods of inserting computerized virtual lesions into CT datasets. 24 physical (synthetic) nodules of three sizes and four morphologies were inserted into an anthropomorphic chest phantom (LUNGMAN, KYOTO KAGAKU). The phantom was scanned (Somatom Definition Flash, Siemens Healthcare) with and without nodules present, and images were reconstructed with filtered back projection and iterative reconstruction (SAFIRE) at 0.6 mm slice thickness using a standard thoracic CT protocol at multiple dose settings. Virtual 3D CAD models based on the physical nodules were virtually inserted (accounting for the system MTF) into the nodule-free CT data using two techniques. These techniques include projection-based and image-based insertion. Nodule volumes were estimated using a commercial segmentation tool (iNtuition, TeraRecon, Inc.). Differences were tested using paired t-tests and R2 goodness of fit between the virtually and physically inserted nodules. Both insertion techniques resulted in nodule volumes very similar to the real nodules (<3% difference) and in most cases the differences were not statistically significant. Also, R2 values were all <0.97 for both insertion techniques. These data imply that these techniques can confidently be used as a means of inserting virtual nodules in CT datasets. These techniques can be instrumental in building hybrid CT datasets composed of patient images with virtually inserted nodules.

  8. Computed tomographic colonography to screen for colorectal cancer, extracolonic cancer, and aortic aneurysm: model simulation with cost-effectiveness analysis.

    PubMed

    Hassan, Cesare; Pickhardt, Perry J; Pickhardt, Perry; Laghi, Andrea; Kim, Daniel H; Kim, Daniel; Zullo, Angelo; Iafrate, Franco; Di Giulio, Lorenzo; Morini, Sergio

    2008-04-14

    In addition to detecting colorectal neoplasia, abdominal computed tomography (CT) with colonography technique (CTC) can also detect unsuspected extracolonic cancers and abdominal aortic aneurysms (AAA).The efficacy and cost-effectiveness of this combined abdominal CT screening strategy are unknown. A computerized Markov model was constructed to simulate the occurrence of colorectal neoplasia, extracolonic malignant neoplasm, and AAA in a hypothetical cohort of 100,000 subjects from the United States who were 50 years of age. Simulated screening with CTC, using a 6-mm polyp size threshold for reporting, was compared with a competing model of optical colonoscopy (OC), both without and with abdominal ultrasonography for AAA detection (OC-US strategy). In the simulated population, CTC was the dominant screening strategy, gaining an additional 1458 and 462 life-years compared with the OC and OC-US strategies and being less costly, with a savings of $266 and $449 per person, respectively. The additional gains for CTC were largely due to a decrease in AAA-related deaths, whereas the modeled benefit from extracolonic cancer downstaging was a relatively minor factor. At sensitivity analysis, OC-US became more cost-effective only when the CTC sensitivity for large polyps dropped to 61% or when broad variations of costs were simulated, such as an increase in CTC cost from $814 to $1300 or a decrease in OC cost from $1100 to $500. With the OC-US approach, suboptimal compliance had a strong negative influence on efficacy and cost-effectiveness. The estimated mortality from CT-induced cancer was less than estimated colonoscopy-related mortality (8 vs 22 deaths), both of which were minor compared with the positive benefit from screening. When detection of extracolonic findings such as AAA and extracolonic cancer are considered in addition to colorectal neoplasia in our model simulation, CT colonography is a dominant screening strategy (ie, more clinically effective and more cost-effective) over both colonoscopy and colonoscopy with 1-time ultrasonography.

  9. Virtual reality simulation training for health professions trainees in gastrointestinal endoscopy.

    PubMed

    Walsh, Catharine M; Sherlock, Mary E; Ling, Simon C; Carnahan, Heather

    2012-06-13

    Traditionally, training in gastrointestinal endoscopy has been based upon an apprenticeship model, with novice endoscopists learning basic skills under the supervision of experienced preceptors in the clinical setting. Over the last two decades, however, the growing awareness of the need for patient safety has brought the issue of simulation-based training to the forefront. While the use of simulation-based training may have important educational and societal advantages, the effectiveness of virtual reality gastrointestinal endoscopy simulators has yet to be clearly demonstrated. To determine whether virtual reality simulation training can supplement and/or replace early conventional endoscopy training (apprenticeship model) in diagnostic oesophagogastroduodenoscopy, colonoscopy and/or sigmoidoscopy for health professions trainees with limited or no prior endoscopic experience. Health professions, educational and computer databases were searched until November 2011 including The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, Scopus, Web of Science, Biosis Previews, CINAHL, Allied and Complementary Medicine Database, ERIC, Education Full Text, CBCA Education, Career and Technical Education @ Scholars Portal, Education Abstracts @ Scholars Portal, Expanded Academic ASAP @ Scholars Portal, ACM Digital Library, IEEE Xplore, Abstracts in New Technologies and Engineering and Computer & Information Systems Abstracts. The grey literature until November 2011 was also searched. Randomised and quasi-randomised clinical trials comparing virtual reality endoscopy (oesophagogastroduodenoscopy, colonoscopy and sigmoidoscopy) simulation training versus any other method of endoscopy training including conventional patient-based training, in-job training, training using another form of endoscopy simulation (e.g. low-fidelity simulator), or no training (however defined by authors) were included.  Trials comparing one method of virtual reality training versus another method of virtual reality training (e.g. comparison of two different virtual reality simulators) were also included. Only trials measuring outcomes on humans in the clinical setting (as opposed to animals or simulators) were included. Two authors (CMS, MES) independently assessed the eligibility and methodological quality of trials, and extracted data on the trial characteristics and outcomes. Due to significant clinical and methodological heterogeneity it was not possible to pool study data in order to perform a meta-analysis. Where data were available for each continuous outcome we calculated standardized mean difference with 95% confidence intervals based on intention-to-treat analysis. Where data were available for dichotomous outcomes we calculated relative risk with 95% confidence intervals based on intention-to-treat-analysis. Thirteen trials, with 278 participants, met the inclusion criteria. Four trials compared simulation-based training with conventional patient-based endoscopy training (apprenticeship model) whereas nine trials compared simulation-based training with no training. Only three trials were at low risk of bias. Simulation-based training, as compared with no training, generally appears to provide participants with some advantage over their untrained peers as measured by composite score of competency, independent procedure completion, performance time, independent insertion depth, overall rating of performance or competency error rate and mucosal visualization. Alternatively, there was no conclusive evidence that simulation-based training was superior to conventional patient-based training, although data were limited. The results of this systematic review indicate that virtual reality endoscopy training can be used to effectively supplement early conventional endoscopy training (apprenticeship model) in diagnostic oesophagogastroduodenoscopy, colonoscopy and/or sigmoidoscopy for health professions trainees with limited or no prior endoscopic experience. However, there remains insufficient evidence to advise for or against the use of virtual reality simulation-based training as a replacement for early conventional endoscopy training (apprenticeship model) for health professions trainees with limited or no prior endoscopic experience. There is a great need for the development of a reliable and valid measure of endoscopic performance prior to the completion of further randomised clinical trials with high methodological quality.

  10. Comparison of tomographic and colonoscopic diagnoses in the presence of colonic wall thickening

    PubMed Central

    İnce, Ali Tüzün; Baysal, Birol; Kayar, Yusuf; Arabacı, Elif; Bilgin, Mehmet; Hamdard, Jamshid; Yay, Adnan; Şentürk, Hakan

    2014-01-01

    Introduction and objective: Colonic wall thickening is a common condition in a number of benignant and malignant diseases. This study investigated the accuracy of radiological diagnoses in patients diagnosed with colonic wall thickening using multislice CT (MDCT). Materials and Method: Files of patients with colonic wall thickening diagnosed with 64-slice MDCT were reviewed retrospectively. The colonoscopy results of these patients were grouped under neoplastic process (cancer and adenomatous polyp), inflammatory bowel disease (IBD), diverticulitis and other etiology (nonspecific events, ischemic colitis, solitary rectal ulcer, external compression, secondary to volvulus and radiotherapy), and the results were statistically evaluated. p values < 0.05 were considered statistically significant. Results: The study was performed on 505 files (290 males [57.4%], 215 females [42.6%], mean age: 49.15 ± 18.4 years). CT and colonoscopic diagnoses were reviewed and the following CT to colonoscopy ratios was observed: neoplastic process: 44.4% vs. 40.2%; IBD: 42.4% vs. 42.4%; diverticulitis: 4% vs. 4.2%; other etiology: 9.3% vs. 3.2%. Colonoscopy failed to identify pathology in 9.9% of the patients. The sensitivity, specificity, PPV, NPV and accuracy of CT were 95.6%, 90.4%, 87.1%, 96.8% and 92.4%, respectively, in detecting neoplastic processes; 97.2%, 97.9%, 97.2%, 97.9% and 97.6%, respectively, in detecting IBD; 90.5%, 99.8%, 95%, 99.6% and 99.4%, respectively, in detecting diverticulitis, and 50%, 96,7%, 62.5%, 94.6% and 92%, respectively, in detecting other etiology. Conclusion: While, accuracy of 64 slice-CT in diagnosing colonic wall thickenings secondary especially to neoplastic processes, IBD and diverticulitis was significantly higher, but differential diagnosis is challenging in pathologies due to other etiologies. PMID:25550962

  11. Virtual Colonoscopy

    MedlinePlus

    ... or broth gelatin in flavors such as lemon, lime, or orange plain coffee or tea, without cream ... milk sports drinks in such flavors as lemon, lime, or orange strained fruit juice, such as apple ...

  12. HealthLines

    MedlinePlus

    ... a particular order, and identified shapes on a computer screen. They were divided into three groups. One ... some people. Virtual colonoscopy uses X-ray and computer technology to create three-dimensional images of the ...

  13. Virtual colonoscopy

    MedlinePlus

    ... ed. Philadelphia, PA: Elsevier Saunders; 2014:chap 77. Review Date 8/1/2017 Updated by: Subodh K. ... Gastroenterologist with Gastrointestinal Specialists of Georgia, Austell, GA. Review provided by VeriMed Healthcare Network. Also reviewed by ...

  14. Colorectal Cancer Screening: Recommendations for Physicians and Patients from the U.S. Multi-Society Task Force on Colorectal Cancer.

    PubMed

    Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J

    2017-07-01

    This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years.

  15. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients.

    PubMed

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F; Long, Daniel J; Bolch, Wesley E; Liu, Bob; Xu, X George

    2015-07-21

    This paper describes the development and testing of VirtualDose--a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the 'software as a service (SaaS)' delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose's functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT-two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.

  16. Controversies in colorectal cancer screening.

    PubMed

    Pox, Christian P

    2014-01-01

    Colorectal cancer (CRC) is one of the most common cancers worldwide and a good candidate for screening programmes. However, there is controversy concerning which of the available screening tests should be used. There is general agreement that screening for CRC in the asymptomatic population should begin at the age of 50. Several different screening methods are available which can be separated into those that mainly detect cancers: faecal occult blood tests [guaiac (FOBT) and immunochemical (FIT)], genetic stool tests, blood tests and the M2-pyruvate kinase (M2-PK) test. Methods that detect cancers and polyps are colonoscopy, sigmoidoscopy, CT-colonography (CT-C) and colon capsule endoscopy. The only tests for which a reduction in CRC mortality compared to no screening have been proven in randomized trials are FOBT and sigmoidoscopy. Several trials suggest that FIT are superior to FOBT in terms of detection rates of cancers and advanced adenomas and possibly compliance. There is indirect evidence suggesting efficacy of colonoscopy as a screening test. The role of CT-C is controversial. There is data suggesting a good sensitivity for neoplasia >9 mm with a lower sensitivity for smaller neoplasia. However, radiation exposure is considered a major limitation in some countries. Unresolved questions include the lesion cut-off for referral to colonoscopy and work-up of extracolonic findings. For other methods, like genetic stool testing using newer markers, blood tests, capsule endoscopy and M2-PK, there is currently insufficient data on screening of the asymptomatic population. Key Messages: Colorectal screening is recommended and should be performed in the form of an organized programme. If detection of early-stage cancers is the aim of a screening programme, FIT seem to be superior to FOBT. If detection and removal of adenomas is the aim of a screening programme, endoscopic methods seem to be good alternatives. Sigmoidoscopy is easier to perform but will likely only have an effect on distal cancers. Colonoscopy is more invasive but enables inspection of the whole colon. The role of CT-C, capsule endoscopy, genetic stool tests, blood tests and M2-PK is currently unknown. © 2014 S. Karger AG, Basel.

  17. Kidney Biopsy

    MedlinePlus

    ... Series Urinary Tract Imaging Urodynamic Testing Virtual Colonoscopy Kidney Biopsy What is a kidney biopsy? A kidney biopsy is a procedure that ... performs procedures using imaging equipment Why is a kidney biopsy performed? A health care provider will perform ...

  18. Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostani, Maryam, E-mail: mbostani@mednet.ucla.edu; McMillan, Kyle; Cagnon, Chris H.

    Purpose: The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. Methods: MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for allmore » exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. Results: The calculated mean percent difference between TLD measurements and Monte Carlo simulations was −4.9% with standard deviation of 8.7% and a range of −22.7% to 5.7%. Conclusions: The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.« less

  19. Colonic metastasis from breast carcinoma: a case report.

    PubMed

    Tsujimura, Kazuma; Teruya, Tsuyoshi; Kiyuna, Masaya; Higa, Kuniki; Higa, Junko; Iha, Kouji; Chinen, Kiyoshi; Asato, Masaya; Takushi, Yasukatsu; Ota, Morihito; Dakeshita, Eijirou; Nakachi, Atsushi; Gakiya, Akira; Shiroma, Hiroshi

    2017-07-05

    Colonic metastasis from breast carcinoma is very rare. Here, we report a case of colonic metastasis from breast carcinoma. The patient was a 51-year-old woman. She had upper abdominal pain, vomiting, and diarrhea, repeatedly. We performed abdominal contrast-enhanced computed tomography (CT) to investigate these symptoms. The CT scan revealed a tumor in the ascending colon with contrast enhancement and showed an expanded small intestine. For further investigation of this tumor, we performed whole positron emission tomography-computed tomography (PET-CT). The PET-CT scan revealed fluorodeoxyglucose uptake in the ascending colon, mesentery, left breast, and left axillary region. Analysis of biopsy samples obtained during colonoscopy revealed signet ring cell-like carcinoma. Moreover, biopsy of the breast tumor revealed invasive lobular carcinoma. Therefore, the preoperative diagnosis was colonic metastasis from breast carcinoma. Open ileocecal resection was performed. The final diagnosis was multiple metastatic breast carcinomas, and the TNM classification was T2N1M1 Stage IV. We presented a rare case of colonic metastasis from breast carcinoma. PET-CT may be useful in the diagnosis of metastatic breast cancer. When analysis of biopsy samples obtained during colonoscopy reveals signet ring cell-like carcinoma, the possibility of breast cancer as the primary tumor should be considered.

  20. Projected national impact of colorectal cancer screening on clinical and economic outcomes and health services demand.

    PubMed

    Ladabaum, Uri; Song, Kenneth

    2005-10-01

    Colorectal cancer (CRC) screening is effective and cost-effective, but the potential national impact of widespread screening is uncertain. It is controversial whether screening colonoscopy can be offered widely and how emerging tests may impact health services demand. Our aim was to produce integrated, comprehensive estimates of the impact of widespread screening on national clinical and economic outcomes and health services demand. We used a Markov model and census data to estimate the national consequences of screening 75% of the US population with conventional and emerging strategies. Screening decreased CRC incidence by 17%-54% to as few as 66,000 cases per year and CRC mortality by 28%-60% to as few as 23,000 deaths per year. With no screening, total annual national CRC-related expenditures were 8.4 US billion dollars. With screening, expenditures for CRC care decreased by 1.5-4.4 US billion dollars but total expenditures increased to 9.2-15.4 US billion dollars. Screening colonoscopy every 10 years required 8.1 million colonoscopies per year including surveillance, with other strategies requiring 17%-58% as many colonoscopies. With improved screening uptake, total colonoscopy demand increased in general, even assuming substantial use of virtual colonoscopy. Despite savings in CRC care, widespread screening is unlikely to be cost saving and may increase national expenditures by 0.8-2.8 US billion dollars per year with conventional tests. The current national endoscopic capacity, as recently estimated, may be adequate to support widespread use of screening colonoscopy in the steady state. The impact of emerging tests on colonoscopy demand will depend on the extent to which they replace screening colonoscopy or increase screening uptake in the population.

  1. Sensitivity and specificity of CT colonography for the detection of colonic neoplasia after positive faecal occult blood testing: systematic review and meta-analysis.

    PubMed

    Plumb, Andrew A; Halligan, Steve; Pendsé, Douglas A; Taylor, Stuart A; Mallett, Susan

    2014-05-01

    CT colonography (CTC) is recommended after positive faecal occult blood testing (FOBt) when colonoscopy is incomplete or infeasible. We aimed to estimate the sensitivity and specificity of CTC for colorectal cancer and adenomatous polyps following positive FOBt via systematic review. The MEDLINE, EMBASE, AMED and Cochrane Library databases were searched for CTC studies reporting sensitivity and specificity for colorectal cancer and adenomatous polyps. Included subjects had tested FOBt-positive by guaiac or immunochemical methods. Per-patient detection rates were summarized via forest plots. Meta-analysis of sensitivity and specificity was conducted using a bivariate random effects model and the average operating point calculated. Of 538 articles considered, 5 met inclusion criteria, describing results from 622 patients. Research study quality was good. CTC had a high per-patient average sensitivity of 88.8 % (95 % CI 83.6 to 92.5 %) for ≥6 mm adenomas or colorectal cancer, with low between-study heterogeneity. Specificity was both more heterogeneous and lower, at an average of 75.4 % (95 % CI 58.6 to 86.8 %). Few studies have investigated CTC in FOBt-positive individuals. CTC is sensitive at a ≥6 mm threshold but specificity is lower and variable. Despite the limited data, these results suggest that CTC may adequately substitute for colonoscopy when the latter is undesirable. • FOBt is the most common mass screening test for colorectal cancer. • Few studies evaluate CT colonography after positive FOBt. • CTC is approximately 89 % sensitive for ≥6 mm adenomas/cancer in this setting. • Specificity is lower, at approximately 75 %, and more variable. • CT colonography is a good alternative when colonoscopy is undesirable.

  2. The potential of imaging techniques as a screening tool for colorectal cancer: a cost-effectiveness analysis.

    PubMed

    Greuter, Marjolein J E; Berkhof, Johannes; Fijneman, Remond J A; Demirel, Erhan; Lew, Jie-Bin; Meijer, Gerrit A; Stoker, Jaap; Coupé, Veerle M H

    2016-07-01

    Imaging may be promising for colorectal cancer (CRC) screening, since it has test characteristics comparable with colonoscopy but is less invasive. We aimed to assess the potential of CT colonography (CTC) and MR colonography (MRC) in terms of (cost-effectiveness) using the Adenoma and Serrated pathway to Colorectal CAncer model. We compared several CTC and MRC strategies with 5- or 10-yearly screening intervals with no screening, 10-yearly colonoscopy screening and biennial faecal immunochemical test (FIT) screening. We assumed trial-based participation rates in the base-case analyses and varied the rates in sensitivity analyses. Incremental lifetime costs and health effects were estimated from a healthcare perspective. The health gain of CTC and MRC was similar and ranged from 0.031 to 0.048 life-year gained compared with no screening, for 2-5 screening rounds. Lifetime costs per person for MRC strategies were €60-110 higher than those for CTC strategies with an equal number of screening rounds. All imaging-based strategies were cost-effective compared with no screening. FIT screening was the dominant screening strategy, leading to most LYG and highest cost-savings. Compared with three rounds of colonoscopy screening, CTC with five rounds was found to be cost-effective in an incremental analysis of imaging strategies. Assumptions on screening participation have a major influence on the ordering of strategies in terms of costs and effects. CTC and MRC have potential for CRC screening, compared with no screening and compared with three rounds of 10-yearly colonoscopy screening. When taking FIT screening as the reference, imaging is not cost-effective. Participation is an important driver of effectiveness and cost estimates. This is the first study to assess the cost-effectiveness of MRC screening for CRC.

  3. Virtual Colonoscopy

    MedlinePlus

    ... 75. back to the top of the page Pros Less invasive way to look for polyps Relatively quick Few complications No sedation May unexpectedly reveal treatable problems outside of the colon Cons Moderate to full bowel prep Slight discomfort when ...

  4. CT biliary cystoscopy of gallbladder polyps

    PubMed Central

    Lou, Ming-Wu; Hu, Wei-Dong; Fan, Yi; Chen, Jin-Hua; E, Zhan-Sen; Yang, Guang-Fu

    2004-01-01

    AIM: CT virtual endoscopy has been used in the study of various organs of body including the biliary tract, however, CT virtual endoseopy in diagnosis of gallbladder polyps has not yet been reported. This study was to evaluate the diagnostic value of CT virtual endoscopy in polyps of the gallbladder. METHODS: Thirty-two cases of gallbladder polyps were examined by CT virtual endoscopy, ultrasound, CT scan with oral biliary contrast separately and confirmed by operation and pathology. CT biliary cystoscopic findings were analyzed and compared with those of ultrasound and CT scan with oral biliary contrast, and evaluated in comparison with operative and pathologic findings in all cases. RESULTS: The detection rate of gallbladder polyps was 93.8%(90/96), 96.9%(93/96) and 79.2%(76/96) for CT cystoscopy, ultrasound and CT scan with oral contrast, respectively. CT biliary cystoscopy corresponded well with ultrasound as well as pathology in demonstrating the location, size and configuration of polyps. CT endoscopy was superior to ultrasound in viewing the polyps in a more precise way, 3 dimensionally from any angle in space, and showing the surface in details. CT biliary cystoscopy was also superior to CT scan with oral biliary contrast in terms of observation of the base of polyps for the presence of a pedicle, detection rates as well as image quality. The smallest polyp detected by CT biliary cystoscopy was measured 1.5 mm×2.2 mm×2.5 mm. CONCLUSION: CT biliary cystoscopy is a non-invasive and accurate technique for diagnosis and management of gallbladder polyps. PMID:15069726

  5. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients

    NASA Astrophysics Data System (ADS)

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F.; Long, Daniel J.; Bolch, Wesley E.; Liu, Bob; Xu, X. George

    2015-07-01

    This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.

  6. Hemodynamic Changes Caused by Flow Diverters in Rabbit Aneurysm Models: Comparison of Virtual and Realistic FD Deployments Based on Micro-CT Reconstruction

    PubMed Central

    Fang, Yibin; Yu, Ying; Cheng, Jiyong; Wang, Shengzhang; Wang, Kuizhong; Liu, Jian-Min; Huang, Qinghai

    2013-01-01

    Adjusting hemodynamics via flow diverter (FD) implantation is emerging as a novel method of treating cerebral aneurysms. However, most previous FD-related hemodynamic studies were based on virtual FD deployment, which may produce different hemodynamic outcomes than realistic (in vivo) FD deployment. We compared hemodynamics between virtual FD and realistic FD deployments in rabbit aneurysm models using computational fluid dynamics (CFD) simulations. FDs were implanted for aneurysms in 14 rabbits. Vascular models based on rabbit-specific angiograms were reconstructed for CFD studies. Real FD configurations were reconstructed based on micro-CT scans after sacrifice, while virtual FD configurations were constructed with SolidWorks software. Hemodynamic parameters before and after FD deployment were analyzed. According to the metal coverage (MC) of implanted FDs calculated based on micro-CT reconstruction, 14 rabbits were divided into two groups (A, MC >35%; B, MC <35%). Normalized mean wall shear stress (WSS), relative residence time (RRT), inflow velocity, and inflow volume in Group A were significantly different (P<0.05) from virtual FD deployment, but pressure was not (P>0.05). The normalized mean WSS in Group A after realistic FD implantation was significantly lower than that of Group B. All parameters in Group B exhibited no significant difference between realistic and virtual FDs. This study confirmed MC-correlated differences in hemodynamic parameters between realistic and virtual FD deployment. PMID:23823503

  7. Use of the stereoscopic virtual reality display system for the detection and characterization of intracranial aneurysms: A Icomparison with conventional computed tomography workstation and 3D rotational angiography.

    PubMed

    Liu, Xiujuan; Tao, Haiquan; Xiao, Xigang; Guo, Binbin; Xu, Shangcai; Sun, Na; Li, Maotong; Xie, Li; Wu, Changjun

    2018-07-01

    This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard. Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms. The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Comparing Tests for Diabetes and Prediabetes: A Quick Reference Guide

    MedlinePlus

    ... Urinary Tract Imaging Urodynamic Testing Virtual Colonoscopy Diabetes & Prediabetes Tests This fact sheet compares the following tests: ... test Confirming Diagnosis of Type 2 Diabetes and Prediabetes Diagnosis must be confirmed unless symptoms are present. ...

  9. Micro-CTvlab: A web based virtual gallery of biological specimens using X-ray microtomography (micro-CT).

    PubMed

    Keklikoglou, Kleoniki; Faulwetter, Sarah; Chatzinikolaou, Eva; Michalakis, Nikitas; Filiopoulou, Irene; Minadakis, Nikos; Panteri, Emmanouela; Perantinos, George; Gougousis, Alexandros; Arvanitidis, Christos

    2016-01-01

    During recent years, X-ray microtomography (micro-CT) has seen an increasing use in biological research areas, such as functional morphology, taxonomy, evolutionary biology and developmental research. Micro-CT is a technology which uses X-rays to create sub-micron resolution images of external and internal features of specimens. These images can then be rendered in a three-dimensional space and used for qualitative and quantitative 3D analyses. However, the online exploration and dissemination of micro-CT datasets are rarely made available to the public due to their large size and a lack of dedicated online platforms for the interactive manipulation of 3D data. Here, the development of a virtual micro-CT laboratory (Micro-CT vlab ) is described, which can be used by everyone who is interested in digitisation methods and biological collections and aims at making the micro-CT data exploration of natural history specimens freely available over the internet. The Micro-CT vlab offers to the user virtual image galleries of various taxa which can be displayed and downloaded through a web application. With a few clicks, accurate, detailed and three-dimensional models of species can be studied and virtually dissected without destroying the actual specimen. The data and functions of the Micro-CT vlab can be accessed either on a normal computer or through a dedicated version for mobile devices.

  10. Colorectal Cancer Screening: Recommendations for Physicians and Patients From the U.S. Multi-Society Task Force on Colorectal Cancer.

    PubMed

    Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J

    2017-07-01

    This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years. Copyright © 2017 AGA Institute, American College of Gastroenterology, and the American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. Results of the National CT Colonography Trial: Questions and Answers

    Cancer.gov

    Learn the results of the National Computerized Tomographic Colonography (CTC) clinical trial, which evaluated how well CTC identifies participants with at least one significantly large polyp using colonoscopy as the gold (or reference) standard.

  12. Patient experiences of colonoscopy, barium enema and CT colonography: a qualitative study.

    PubMed

    Von Wagner, C; Knight, K; Halligan, S; Atkin, W; Lilford, R; Morton, D; Wardle, J

    2009-01-01

    Previous studies of patient experience with bowel screening tests, in particular CT colonography (CTC), have superimposed global rating scales and not explored individual experience in detail. To redress this, we performed qualitative interviews in order to characterize patient expectations and experiences in depth. Following ethical permission, 16 patients undergoing CTC, 18 undergoing colonoscopy and 15 undergoing barium enema agreed to a semi-structured interview by a health psychologist. Interviews were recorded, responses transcribed and themes extracted with the aim of assimilating individual experiences to facilitate subsequent development and interpretation of quantitative surveys of overall satisfaction with each diagnostic test. Transcript analysis identified three principal themes: physical sensations, social interactions and information provision. Physical sensations differed for each test but were surprisingly well tolerated overall. Social interactions with staff were perceived as very important in colouring the whole experience, particularly in controlling the feelings of embarrassment, which was critical for all procedures. Information provision was also an important determinant of experience. Verbal feedback was most common during colonoscopy and invariably reassuring. However, patients undergoing CTC received little visual or verbal feedback and were often confused regarding the test outcome. Barium enema had no specific advantage over other tests. Qualitative interviews provided important perspectives on patient experience. Our data demonstrated that models describing the quality of medical encounters are applicable to single diagnostic episodes. Staff interactions and information provision were particularly important. We found advantages specific to both CTC and colonoscopy but none for barium enema. CTC could benefit greatly from improved information provision following examination.

  13. Cost-effectiveness analysis of colorectal cancer screening methods in Iran.

    PubMed

    Allameh, Zahra; Davari, Majid; Emami, Mohammad Hasan

    2011-03-01

    Screening can prevent colorectal cancer from becoming advanced by early detection of precancerous lesions. Cost-effectiveness analysis of colorectal cancer screening methods is highly necessary due to increased prevalence, decreased age at onset and the limited budget in Iran. Methods of screening currently available in Iran were selected. A systematic search revealed the sensitivity and specificity of each method. For this study, a model for a 20 year screening period of a population of 100,000 apparently healthy persons of ages 45-65 years in Isfahan Province was used. The cost-effectiveness of each method and the ratio of cost-effectiveness were calculated based on this model. The most and the least effective methods were CT colonography and fecal occult blood test, respectively. The highest and lowest expenditures in the governmental sector were related to fecal occult blood test and flexible sigmoidoscopy and in the private sector, to CT colonography and fecal occult blood test, respectively. The cost per cancer detected in 20 years of screening in the governmental sector was 0.28, 0.22 and 0.42 billion Rials, respectively for screening by colonoscopy, flexible sigmoidoscopy and fecal occult blood test. In the private sector, these were 1.54 (colonoscopy), 1.68 (flexible sigmoidoscopy), and 1.60 (fecal occult blood test) billion and 2.58 billion Rials for CT colonography, respectively. Although CT colonography is the most effective method, it needs a budget of 2.58 billion Rials for each screened patient. If costs in the governmental sector are considered, flexible sigmoidoscopy would be the most cost-effective method for screening the 45 - 65-year-old population in Iran.

  14. CT colonography with reduced bowel preparation after incomplete colonoscopy in the elderly.

    PubMed

    Iafrate, F; Hassan, C; Zullo, A; Stagnitti, A; Ferrari, R; Spagnuolo, A; Laghi, A

    2008-07-01

    We prospectively assessed the feasibility and acceptance of computerized tomographic colonography (CTC) without bowel cathartic preparation in elderly patients after incomplete colonoscopy. A total of 136 patients underwent CTC without cathartic preparation. The time delay between conventional colonoscopy and CTC ranged between 3 and 20 days, depending on the clinical situation. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. CTCs were interpreted using a primary two-dimensional (2D) approach and 3D images for further characterization. Patients were interviewed before and 2 weeks after CTC to assess preparation acceptance. CTC was feasible and technically successful in all the 136 patients. Fecal tagging was judged as excellent in 113 (83%) patients and sufficient in 23 (17%). Average CT image interpretation time was 14.8 min. Six (4.4%) cases of colorectal cancer and nine (6.6%) large polyps were detected, as well as 23 (11.3%) extracolonic findings of high clinical importance. No major side effect occurred, although 25% patients reported minor side effects, especially diarrhea. Overall, 76/98 patients replied that they would be willing to repeat the test if necessary. CTC without cathartic preparation is a technically feasible and safe procedure to complete a colonic study in the elderly, prompting its use in clinical practice.

  15. Prevalence and malignancy risk of focal colorectal incidental uptake detected by (18)F-FDG-PET or PET/CT: a meta-analysis.

    PubMed

    Treglia, Giorgio; Taralli, Silvia; Salsano, Marco; Muoio, Barbara; Sadeghi, Ramin; Giovanella, Luca

    2014-06-01

    The aim of the study was to meta-analyze published data about prevalence and malignancy risk of focal colorectal incidentalomas (FCIs) detected by Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography ((18)F-FDG-PET or PET/CT). A comprehensive computer literature search of studies published through July 31(st) 2012 regarding FCIs detected by (18)F-FDG-PET or PET/CT was performed. Pooled prevalence of patients with FCIs and risk of malignant or premalignant FCIs after colonoscopy or histopathology verification were calculated. Furthermore, separate calculations for geographic areas were performed. Finally, average standardized uptake values (SUV) in malignant, premalignant and benign FCIs were reported. Thirty-two studies comprising 89,061 patients evaluated by (18)F-FDG-PET or PET/CT were included. The pooled prevalence of FCIs detected by (18)F-FDG-PET or PET/CT was 3.6% (95% confidence interval [95% CI]: 2.6-4.7%). Overall, 1,044 FCIs detected by (18)F-FDG-PET or PET/CT underwent colonoscopy or histopathology evaluation. Pooled risk of malignant or premalignant lesions was 68% (95% CI: 60-75%). Risk of malignant and premalignant FCIs in Asia-Oceania was lower compared to that of Europe and America. A significant overlap in average SUV was found between malignant, premalignant and benign FCIs. FCIs are observed in a not negligible number of patients who undergo (18)F-FDG-PET or PET/CT studies with a high risk of malignant or premalignant lesions. SUV is not reliable as a tool to differentiate between malignant, premalignant and benign FCIs. Further investigation is warranted whenever FCIs are detected by (18)F-FDG-PET or PET/CT.

  16. Prevalence and malignancy risk of focal colorectal incidental uptake detected by 18F-FDG-PET or PET/CT: a meta-analysis

    PubMed Central

    Treglia, Giorgio; Taralli, Silvia; Salsano, Marco; Muoio, Barbara; Sadeghi, Ramin; Giovanella, Luca

    2014-01-01

    Background The aim of the study was to meta-analyze published data about prevalence and malignancy risk of focal colorectal incidentalomas (FCIs) detected by Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography (18F-FDG-PET or PET/CT). Methods A comprehensive computer literature search of studies published through July 31st 2012 regarding FCIs detected by 18F-FDG-PET or PET/CT was performed. Pooled prevalence of patients with FCIs and risk of malignant or premalignant FCIs after colonoscopy or histopathology verification were calculated. Furthermore, separate calculations for geographic areas were performed. Finally, average standardized uptake values (SUV) in malignant, premalignant and benign FCIs were reported. Results Thirty-two studies comprising 89,061 patients evaluated by 18F-FDG-PET or PET/CT were included. The pooled prevalence of FCIs detected by 18F-FDG-PET or PET/CT was 3.6% (95% confidence interval [95% CI]: 2.6–4.7%). Overall, 1,044 FCIs detected by 18F-FDG-PET or PET/CT underwent colonoscopy or histopathology evaluation. Pooled risk of malignant or premalignant lesions was 68% (95% CI: 60–75%). Risk of malignant and premalignant FCIs in Asia-Oceania was lower compared to that of Europe and America. A significant overlap in average SUV was found between malignant, premalignant and benign FCIs. Conclusions FCIs are observed in a not negligible number of patients who undergo 18F-FDG-PET or PET/CT studies with a high risk of malignant or premalignant lesions. SUV is not reliable as a tool to differentiate between malignant, premalignant and benign FCIs. Further investigation is warranted whenever FCIs are detected by 18F-FDG-PET or PET/CT. PMID:24991198

  17. μCT of ex-vivo stained mouse hearts and embryos enables a precise match between 3D virtual histology, classical histology and immunochemistry

    PubMed Central

    Larsson, Emanuel; Martin, Sabine; Lazzarini, Marcio; Tromba, Giuliana; Missbach-Guentner, Jeannine; Pinkert-Leetsch, Diana; Katschinski, Dörthe M.; Alves, Frauke

    2017-01-01

    The small size of the adult and developing mouse heart poses a great challenge for imaging in preclinical research. The aim of the study was to establish a phosphotungstic acid (PTA) ex-vivo staining approach that efficiently enhances the x-ray attenuation of soft-tissue to allow high resolution 3D visualization of mouse hearts by synchrotron radiation based μCT (SRμCT) and classical μCT. We demonstrate that SRμCT of PTA stained mouse hearts ex-vivo allows imaging of the cardiac atrium, ventricles, myocardium especially its fibre structure and vessel walls in great detail and furthermore enables the depiction of growth and anatomical changes during distinct developmental stages of hearts in mouse embryos. Our x-ray based virtual histology approach is not limited to SRμCT as it does not require monochromatic and/or coherent x-ray sources and even more importantly can be combined with conventional histological procedures. Furthermore, it permits volumetric measurements as we show for the assessment of the plaque volumes in the aortic valve region of mice from an ApoE-/- mouse model. Subsequent, Masson-Goldner trichrome staining of paraffin sections of PTA stained samples revealed intact collagen and muscle fibres and positive staining of CD31 on endothelial cells by immunohistochemistry illustrates that our approach does not prevent immunochemistry analysis. The feasibility to scan hearts already embedded in paraffin ensured a 100% correlation between virtual cut sections of the CT data sets and histological heart sections of the same sample and may allow in future guiding the cutting process to specific regions of interest. In summary, since our CT based virtual histology approach is a powerful tool for the 3D depiction of morphological alterations in hearts and embryos in high resolution and can be combined with classical histological analysis it may be used in preclinical research to unravel structural alterations of various heart diseases. PMID:28178293

  18. [Virtual CT-pneumocystoscopy: indications, advantages and limitations. Our experience].

    PubMed

    Regine, Giovanni; Atzori, Maurizio; Buffa, Vitaliano; Miele, Vittorio; Ialongo, Pasquale; Adami, Loredana

    2003-09-01

    The use of CT volume-rendering techniques allows the evaluation of visceral organs without the need for endoscopy. Conventional endoscopic evaluation of the bladder is limited by the invasiveness of the technique and the difficulty exploring the entire bladder. Virtual evaluation of the bladder by three-dimensional CT reconstruction offers potential advantages and can be used in place of endoscopy. This study investigates the sensitivity of virtual CT in assessing lesion of the bladder wall to compare it with that of conventional endoscopy, and outlines the indications, advantages and disadvantages of virtual CT-pneumocystography. Between September 2001 and May 2002, 21 patients with haematuria and positive cystoscopic findings were studied. After an initial assessment by ultrasound, the patients underwent pelvic CT as a single volumetric scan after preliminary air distension of the bladder by means of 12 F Foley catheter. The images were processed on an independent workstation (Advantage 3.0 GE) running dedicated software for endoluminal navigation. The lesions detected by endoscopy were classified as sessile or pedunculated, and according to size (more or less than 5 mm). Finally, the results obtained at virtual cystoscopy were evaluated by two radiologists blinded to the conventional cystoscopy results. Thirty lesions (24 pedunculated, 6 sessile) were detected at conventional cystoscopy in 16 patients (multiple polyposis in 3 cases). Virtual cystoscopy identified 23 lesions (19 pedunculated and 4 sessile). The undetected lesions were pedunculated <5 mm (5 cases) and sessile (2 cases). One correctly identified pedunculated lesion was associated with a bladder stone. Good quality virtual images were obtained in all of the patients. In only one patient with multiple polyposis the quality of the virtual endoscopic evaluation was limited by the patient's intolerance to bladder distension, although identification of the lesions was not compromised. The overall sensitivity was 77%; this was higher for pedunculated lesions (79%) than for sessile lesions (50%). The virtual technique is less invasive and tends to be associated with fewer complications than is conventional cystoscopy. It also demonstrated a good sensitivity for evaluating pedunculated lesions, allowing evaluation of the bladder base and anterior wall, sites that are commonly poorly accessible at conventional cystoscopy. Further advantages of the virtual technique include the possibility of accurately measuring the extent of the lesion and obtaining virtual images even in patients with severe urethral obstruction and active bleeding. The limitations include the inability to obtain tissue for histologic examination or to perform endoscopic resection of pedunculated lesions. The technique is less sensitive than conventional cystoscopy in the detection of sessile lesions or very small polyps (<5 mm). Furthermore, diffuse wall thickening reduces bladder distension thereby preventing optimal evaluation. The most valuable indication appears to be the follow-up of treated wall lesions. Virtual CT-pneumocystoscopy can replace conventional cystoscopy in cases with pedunculated lesions when there is no need for biopsy, when the lesions are located at the bladder base or when cystoscopic instrumentation cannot be introduced into the bladder due to stenosis. Virtual pneumocystoscopy can also be used in the follow-up of treated polypoid lesions in association with pelvic CT-angiography.

  19. Direct Visuo-Haptic 4D Volume Rendering Using Respiratory Motion Models.

    PubMed

    Fortmeier, Dirk; Wilms, Matthias; Mastmeyer, Andre; Handels, Heinz

    2015-01-01

    This article presents methods for direct visuo-haptic 4D volume rendering of virtual patient models under respiratory motion. Breathing models are computed based on patient-specific 4D CT image data sequences. Virtual patient models are visualized in real-time by ray casting based rendering of a reference CT image warped by a time-variant displacement field, which is computed using the motion models at run-time. Furthermore, haptic interaction with the animated virtual patient models is provided by using the displacements computed at high rendering rates to translate the position of the haptic device into the space of the reference CT image. This concept is applied to virtual palpation and the haptic simulation of insertion of a virtual bendable needle. To this aim, different motion models that are applicable in real-time are presented and the methods are integrated into a needle puncture training simulation framework, which can be used for simulated biopsy or vessel puncture in the liver. To confirm real-time applicability, a performance analysis of the resulting framework is given. It is shown that the presented methods achieve mean update rates around 2,000 Hz for haptic simulation and interactive frame rates for volume rendering and thus are well suited for visuo-haptic rendering of virtual patients under respiratory motion.

  20. Treatment response assessment of radiofrequency ablation for hepatocellular carcinoma: usefulness of virtual CT sonography with magnetic navigation.

    PubMed

    Minami, Yasunori; Kitai, Satoshi; Kudo, Masatoshi

    2012-03-01

    Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. Sixty-one patients with 88 HCCs measuring 0.5-1.3 cm (mean±SD, 1.0±0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1-5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P=0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P=0.13). The safety margin should be overestimated on axial CT images in 8 nodules. Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. Image processing, geometric modeling and data management for development of a virtual bone surgery system.

    PubMed

    Niu, Qiang; Chi, Xiaoyi; Leu, Ming C; Ochoa, Jorge

    2008-01-01

    This paper describes image processing, geometric modeling and data management techniques for the development of a virtual bone surgery system. Image segmentation is used to divide CT scan data into different segments representing various regions of the bone. A region-growing algorithm is used to extract cortical bone and trabecular bone structures systematically and efficiently. Volume modeling is then used to represent the bone geometry based on the CT scan data. Material removal simulation is achieved by continuously performing Boolean subtraction of the surgical tool model from the bone model. A quadtree-based adaptive subdivision technique is developed to handle the large set of data in order to achieve the real-time simulation and visualization required for virtual bone surgery. A Marching Cubes algorithm is used to generate polygonal faces from the volumetric data. Rendering of the generated polygons is performed with the publicly available VTK (Visualization Tool Kit) software. Implementation of the developed techniques consists of developing a virtual bone-drilling software program, which allows the user to manipulate a virtual drill to make holes with the use of a PHANToM device on a bone model derived from real CT scan data.

  2. Differences in detection rates of adenomas and serrated polyps in screening versus surveillance colonoscopies, based on the new hampshire colonoscopy registry.

    PubMed

    Anderson, Joseph C; Butterly, Lynn F; Goodrich, Martha; Robinson, Christina M; Weiss, Julia E

    2013-10-01

    The adenoma detection rate (ADR) is an important quality indicator originally developed for screening colonoscopies. However, it is unclear whether the ADR should be calculated using data from screening and surveillance examinations. The recommended benchmark ADR for screening examinations is 20% (15% for women and 25% for men ≥50 y). There are few data available to compare ADRs from surveillance vs screening colonoscopies. We used a population-based registry to compare ADRs from screening vs surveillance colonoscopies. The serrated polyp detection rate (SDR), a potential new quality indicator, also was examined. By using data from the statewide New Hampshire Colonoscopy Registry, we excluded incomplete and diagnostic colonoscopies, and those performed in patients with inflammatory bowel disease, familial syndromes, or poor bowel preparation. We calculated the ADR and SDR (number of colonoscopies with at least 1 adenoma or serrated polyp detected, respectively, divided by the number of colonoscopies) from 9100 colonoscopies. The ADR and SDR were compared by colonoscopy indication (screening, surveillance), age at colonoscopy (50-64 y, ≥65 y), and sex. The ADR was significantly higher in surveillance colonoscopies (37%) than screening colonoscopies (25%; P < .001). This difference was observed for both sexes and age groups. There was a smaller difference in the SDR of screening (8%) vs surveillance colonoscopies (10%; P < .001). In a population-based study, we found that addition of data from surveillance colonoscopies increased the ADR but had a smaller effect on the SDR. These findings indicate that when calculating ADR as a quality measure, endoscopists should use screening, rather than surveillance colonoscopy, data. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.

  3. Differences in Detection Rates of Adenomas and Serrated Polyps in Screening Versus Surveillance Colonoscopies, Based on the New Hampshire Colonoscopy Registry

    PubMed Central

    ANDERSON, JOSEPH C.; BUTTERLY, LYNN; GOODRICH, MARTHA; ROBINSON, CHRISTINA M.; WEISS, JULIA E.

    2013-01-01

    BACKGROUND & AIMS The adenoma detection rate (ADR) is an important quality indicator originally developed for screening colonoscopies. However, it is unclear whether the ADR should be calculated using data from screening and surveillance examinations. The recommended benchmark ADR for screening examinations is 20% (15% for women and 25% for men ≥ 50 y). There are few data available to compare ADRs from surveillance vs screening colonoscopies. We used a population-based registry to compare ADRs from screening vs surveillance colonoscopies. The serrated polyp detection rate (SDR), a potential new quality indicator, also was examined. METHODS By using data from the statewide New Hampshire Colonoscopy Registry, we excluded incomplete and diagnostic colonoscopies, and those performed in patients with inflammatory bowel disease, familial syndromes, or poor bowel preparation. We calculated the ADR and SDR (number of colonoscopies with at least 1 adenoma or serrated polyp detected, respectively, divided by the number of colonoscopies) from 9100 colonoscopies. The ADR and SDR were compared by colonoscopy indication (screening, surveillance), age at colonoscopy (50–64 y, ≥65 y), and sex. RESULTS The ADR was significantly higher in surveillance colonoscopies (37%) than screening colonoscopies (25%; P < .001). This difference was observed for both sexes and age groups. There was a smaller difference in the SDR of screening (8%) vs surveillance colonoscopies (10%; P < .001). CONCLUSIONS In a population-based study, we found that addition of data from surveillance colonoscopies increased the ADR, but had a smaller effect on the SDR. These findings indicate that when calculating ADR as a quality measure, endoscopists should use screening, rather than surveillance colonoscopy, data. PMID:23660415

  4. Cost analysis of colorectal cancer screening with CT colonography in Italy.

    PubMed

    Mantellini, Paola; Lippi, Giuseppe; Sali, Lapo; Grazzini, Grazia; Delsanto, Silvia; Mallardi, Beatrice; Falchini, Massimo; Castiglione, Guido; Carozzi, Francesca Maria; Mascalchi, Mario; Milani, Stefano; Ventura, Leonardo; Zappa, Marco

    2018-06-01

    Unit costs of screening CT colonography (CTC) can be useful for cost-effectiveness analyses and for health care decision-making. We evaluated the unit costs of CTC as a primary screening test for colorectal cancer in the setting of a randomized trial in Italy. Data were collected within the randomized SAVE trial. Subjects were invited to screening CTC by mail and requested to have a pre-examination consultation. CTCs were performed with 64- and 128-slice CT scanners after reduced or full bowel preparation. Activity-based costing was used to determine unit costs per-process, per-participant to screening CTC, and per-subject with advanced neoplasia. Among 5242 subjects invited to undergo screening CTC, 1312 had pre-examination consultation and 1286 ultimately underwent CTC. Among 129 subjects with a positive CTC, 126 underwent assessment colonoscopy and 67 were ultimately diagnosed with advanced neoplasia (i.e., cancer or advanced adenoma). Cost per-participant of the entire screening CTC pathway was €196.80. Average cost per-participant for the screening invitation process was €17.04 and €9.45 for the pre-examination consultation process. Average cost per-participant of the CTC execution and reading process was €146.08 and of the diagnostic assessment colonoscopy process was €24.23. Average cost per-subject with advanced neoplasia was €3777.30. Cost of screening CTC was €196.80 per-participant. Our data suggest that the more relevant cost of screening CTC, amenable of intervention, is related to CTC execution and reading process.

  5. Crowdsourcing for identification of polyp-free segments in virtual colonoscopy videos

    NASA Astrophysics Data System (ADS)

    Park, Ji Hwan; Mirhosseini, Seyedkoosha; Nadeem, Saad; Marino, Joseph; Kaufman, Arie; Baker, Kevin; Barish, Matthew

    2017-03-01

    Virtual colonoscopy (VC) allows a physician to virtually navigate within a reconstructed 3D colon model searching for colorectal polyps. Though VC is widely recognized as a highly sensitive and specific test for identifying polyps, one limitation is the reading time, which can take over 30 minutes per patient. Large amounts of the colon are often devoid of polyps, and a way of identifying these polyp-free segments could be of valuable use in reducing the required reading time for the interrogating radiologist. To this end, we have tested the ability of the collective crowd intelligence of non-expert workers to identify polyp candidates and polyp-free regions. We presented twenty short videos flying through a segment of a virtual colon to each worker, and the crowd was asked to determine whether or not a possible polyp was observed within that video segment. We evaluated our framework on Amazon Mechanical Turk and found that the crowd was able to achieve a sensitivity of 80.0% and specificity of 86.5% in identifying video segments which contained a clinically proven polyp. Since each polyp appeared in multiple consecutive segments, all polyps were in fact identified. Using the crowd results as a first pass, 80% of the video segments could in theory be skipped by the radiologist, equating to a significant time savings and enabling more VC examinations to be performed.

  6. Material Separation Using Dual-Energy CT: Current and Emerging Applications.

    PubMed

    Patino, Manuel; Prochowski, Andrea; Agrawal, Mukta D; Simeone, Frank J; Gupta, Rajiv; Hahn, Peter F; Sahani, Dushyant V

    2016-01-01

    Dual-energy (DE) computed tomography (CT) offers the opportunity to generate material-specific images on the basis of the atomic number Z and the unique mass attenuation coefficient of a particular material at different x-ray energies. Material-specific images provide qualitative and quantitative information about tissue composition and contrast media distribution. The most significant contribution of DE CT-based material characterization comes from the capability to assess iodine distribution through the creation of an image that exclusively shows iodine. These iodine-specific images increase tissue contrast and amplify subtle differences in attenuation between normal and abnormal tissues, improving lesion detection and characterization in the abdomen. In addition, DE CT enables computational removal of iodine influence from a CT image, generating virtual noncontrast images. Several additional materials, including calcium, fat, and uric acid, can be separated, permitting imaging assessment of metabolic imbalances, elemental deficiencies, and abnormal deposition of materials within tissues. The ability to obtain material-specific images from a single, contrast-enhanced CT acquisition can complement the anatomic knowledge with functional information, and may be used to reduce the radiation dose by decreasing the number of phases in a multiphasic CT examination. DE CT also enables generation of energy-specific and virtual monochromatic images. Clinical applications of DE CT leverage both material-specific images and virtual monochromatic images to expand the current role of CT and overcome several limitations of single-energy CT. (©)RSNA, 2016.

  7. Optimal use of colonoscopy and fecal immunochemical test for population-based colorectal cancer screening: a cost-effectiveness analysis using Japanese data.

    PubMed

    Sekiguchi, Masau; Igarashi, Ataru; Matsuda, Takahisa; Matsumoto, Minori; Sakamoto, Taku; Nakajima, Takeshi; Kakugawa, Yasuo; Yamamoto, Seiichiro; Saito, Hiroshi; Saito, Yutaka

    2016-02-01

    There have been few cost-effectiveness analyses of population-based colorectal cancer screening in Japan, and there is no consensus on the optimal use of total colonoscopy and the fecal immunochemical test for colorectal cancer screening with regard to cost-effectiveness and total colonoscopy workload. The present study aimed to examine the cost-effectiveness of colorectal cancer screening using Japanese data to identify the optimal use of total colonoscopy and fecal immunochemical test. We developed a Markov model to assess the cost-effectiveness of colorectal cancer screening offered to an average-risk population aged 40 years or over. The cost, quality-adjusted life-years and number of total colonoscopy procedures required were evaluated for three screening strategies: (i) a fecal immunochemical test-based strategy; (ii) a total colonoscopy-based strategy; (iii) a strategy of adding population-wide total colonoscopy at 50 years to a fecal immunochemical test-based strategy. All three strategies dominated no screening. Among the three, Strategy 1 was dominated by Strategy 3, and the incremental cost per quality-adjusted life-years gained for Strategy 2 against Strategies 1 and 3 were JPY 293 616 and JPY 781 342, respectively. Within the Japanese threshold (JPY 5-6 million per QALY gained), Strategy 2 was the most cost-effective, followed by Strategy 3; however, Strategy 2 required more than double the number of total colonoscopy procedures than the other strategies. The total colonoscopy-based strategy could be the most cost-effective for population-based colorectal cancer screening in Japan. However, it requires more total colonoscopy procedures than the other strategies. Depending on total colonoscopy capacity, the strategy of adding total colonoscopy for individuals at a specified age to a fecal immunochemical test-based screening may be an optimal solution. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Test of 3D CT reconstructions by EM + TV algorithm from undersampled data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evseev, Ivan; Ahmann, Francielle; Silva, Hamilton P. da

    2013-05-06

    Computerized tomography (CT) plays an important role in medical imaging for diagnosis and therapy. However, CT imaging is connected with ionization radiation exposure of patients. Therefore, the dose reduction is an essential issue in CT. In 2011, the Expectation Maximization and Total Variation Based Model for CT Reconstruction (EM+TV) was proposed. This method can reconstruct a better image using less CT projections in comparison with the usual filtered back projection (FBP) technique. Thus, it could significantly reduce the overall dose of radiation in CT. This work reports the results of an independent numerical simulation for cone beam CT geometry withmore » alternative virtual phantoms. As in the original report, the 3D CT images of 128 Multiplication-Sign 128 Multiplication-Sign 128 virtual phantoms were reconstructed. It was not possible to implement phantoms with lager dimensions because of the slowness of code execution even by the CORE i7 CPU.« less

  9. Micro-CTvlab: A web based virtual gallery of biological specimens using X-ray microtomography (micro-CT)

    PubMed Central

    Faulwetter, Sarah; Chatzinikolaou, Eva; Michalakis, Nikitas; Filiopoulou, Irene; Minadakis, Nikos; Panteri, Emmanouela; Perantinos, George; Gougousis, Alexandros; Arvanitidis, Christos

    2016-01-01

    Abstract Background During recent years, X-ray microtomography (micro-CT) has seen an increasing use in biological research areas, such as functional morphology, taxonomy, evolutionary biology and developmental research. Micro-CT is a technology which uses X-rays to create sub-micron resolution images of external and internal features of specimens. These images can then be rendered in a three-dimensional space and used for qualitative and quantitative 3D analyses. However, the online exploration and dissemination of micro-CT datasets are rarely made available to the public due to their large size and a lack of dedicated online platforms for the interactive manipulation of 3D data. Here, the development of a virtual micro-CT laboratory (Micro-CTvlab) is described, which can be used by everyone who is interested in digitisation methods and biological collections and aims at making the micro-CT data exploration of natural history specimens freely available over the internet. New information The Micro-CTvlab offers to the user virtual image galleries of various taxa which can be displayed and downloaded through a web application. With a few clicks, accurate, detailed and three-dimensional models of species can be studied and virtually dissected without destroying the actual specimen. The data and functions of the Micro-CTvlab can be accessed either on a normal computer or through a dedicated version for mobile devices. PMID:27956848

  10. Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis

    PubMed Central

    Palimaka, Stefan; Blackhouse, Gord; Goeree, Ron

    2015-01-01

    Background Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. Objectives The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario health budget of implementing colon capsule endoscopy for detecting advanced colorectal polyps among adult patients who have been referred for computed tomographic (CT) colonography. Methods We performed an original cost-effectiveness analysis to assess the additional cost of CT colonography and colon capsule endoscopy resulting from misdiagnoses. We generated diagnostic accuracy data from a clinical evidence-based analysis (reported separately), and we developed a deterministic Markov model to estimate the additional long-term costs and life-years lost due to false-negative results. We then also performed a budget impact analysis using data from Ontario administrative sources. One-year costs were estimated for CT colonography and colon capsule endoscopy (replacing all CT colonography procedures, and replacing only those CT colonography procedures in patients with an incomplete colonoscopy within the previous year). We conducted this analysis from the payer perspective. Results Using the point estimates of diagnostic accuracy from the head-to-head study between colon capsule endoscopy and CT colonography, we found the additional cost of false-positive results for colon capsule endoscopy to be $0.41 per patient, while additional false-negatives for the CT colonography arm generated an added cost of $116 per patient, with 0.0096 life-years lost per patient due to cancer. This results in an additional cost of $26,750 per life-year gained for colon capsule endoscopy compared with CT colonography. The total 1-year cost to replace all CT colonography procedures with colon capsule endoscopy in Ontario is about $2.72 million; replacing only those CT colonography procedures in patients with an incomplete colonoscopy in the previous year would cost about $740,600 in the first year. Limitations The difference in accuracy between colon capsule endoscopy and CT colonography was not statistically significant for the detection of advanced adenomas (≥ 10 mm in diameter), according to the head-to-head clinical study from which the diagnostic accuracy was taken. This leads to uncertainty in the economic analysis, with results highly sensitive to changes in diagnostic accuracy. Conclusions The cost-effectiveness of colon capsule endoscopy for use in patients referred for CT colonography is $26,750 per life-year, assuming an increased sensitivity of colon capsule endoscopy. Replacement of CT colonography with colon capsule endoscopy is associated with moderate costs to the health care system. PMID:26366240

  11. A method for evaluating the performance of computer-aided detection of pulmonary nodules in lung cancer CT screening: detection limit for nodule size and density

    PubMed Central

    Kobayashi, Hajime; Ohkubo, Masaki; Narita, Akihiro; Marasinghe, Janaka C; Murao, Kohei; Matsumoto, Toru; Sone, Shusuke

    2017-01-01

    Objective: We propose the application of virtual nodules to evaluate the performance of computer-aided detection (CAD) of lung nodules in cancer screening using low-dose CT. Methods: The virtual nodules were generated based on the spatial resolution measured for a CT system used in an institution providing cancer screening and were fused into clinical lung images obtained at that institution, allowing site specificity. First, we validated virtual nodules as an alternative to artificial nodules inserted into a phantom. In addition, we compared the results of CAD analysis between the real nodules (n = 6) and the corresponding virtual nodules. Subsequently, virtual nodules of various sizes and contrasts between nodule density and background density (ΔCT) were inserted into clinical images (n = 10) and submitted for CAD analysis. Results: In the validation study, 46 of 48 virtual nodules had the same CAD results as artificial nodules (kappa coefficient = 0.913). Real nodules and the corresponding virtual nodules showed the same CAD results. The detection limits of the tested CAD system were determined in terms of size and density of peripheral lung nodules; we demonstrated that a nodule with a 5-mm diameter was detected when the nodule had a ΔCT > 220 HU. Conclusion: Virtual nodules are effective in evaluating CAD performance using site-specific scan/reconstruction conditions. Advances in knowledge: Virtual nodules can be an effective means of evaluating site-specific CAD performance. The methodology for guiding the detection limit for nodule size/density might be a useful evaluation strategy. PMID:27897029

  12. Robust augmented reality registration method for localization of solid organs' tumors using CT-derived virtual biomechanical model and fluorescent fiducials.

    PubMed

    Kong, Seong-Ho; Haouchine, Nazim; Soares, Renato; Klymchenko, Andrey; Andreiuk, Bohdan; Marques, Bruno; Shabat, Galyna; Piechaud, Thierry; Diana, Michele; Cotin, Stéphane; Marescaux, Jacques

    2017-07-01

    Augmented reality (AR) is the fusion of computer-generated and real-time images. AR can be used in surgery as a navigation tool, by creating a patient-specific virtual model through 3D software manipulation of DICOM imaging (e.g., CT scan). The virtual model can be superimposed to real-time images enabling transparency visualization of internal anatomy and accurate localization of tumors. However, the 3D model is rigid and does not take into account inner structures' deformations. We present a concept of automated AR registration, while the organs undergo deformation during surgical manipulation, based on finite element modeling (FEM) coupled with optical imaging of fluorescent surface fiducials. Two 10 × 1 mm wires (pseudo-tumors) and six 10 × 0.9 mm fluorescent fiducials were placed in ex vivo porcine kidneys (n = 10). Biomechanical FEM-based models were generated from CT scan. Kidneys were deformed and the shape changes were identified by tracking the fiducials, using a near-infrared optical system. The changes were registered automatically with the virtual model, which was deformed accordingly. Accuracy of prediction of pseudo-tumors' location was evaluated with a CT scan in the deformed status (ground truth). In vivo: fluorescent fiducials were inserted under ultrasound guidance in the kidney of one pig, followed by a CT scan. The FEM-based virtual model was superimposed on laparoscopic images by automatic registration of the fiducials. Biomechanical models were successfully generated and accurately superimposed on optical images. The mean measured distance between the estimated tumor by biomechanical propagation and the scanned tumor (ground truth) was 0.84 ± 0.42 mm. All fiducials were successfully placed in in vivo kidney and well visualized in near-infrared mode enabling accurate automatic registration of the virtual model on the laparoscopic images. Our preliminary experiments showed the potential of a biomechanical model with fluorescent fiducials to propagate the deformation of solid organs' surface to their inner structures including tumors with good accuracy and automatized robust tracking.

  13. Dual-energy CT revisited with multidetector CT: review of principles and clinical applications.

    PubMed

    Karçaaltıncaba, Muşturay; Aktaş, Aykut

    2011-09-01

    Although dual-energy CT (DECT) was first conceived in the 1970s, it was not widely used for CT indications. Recently, the simultaneous acquisition of volumetric dual-energy data has been introduced using multidetector CT (MDCT) with two X-ray tubes and rapid kVp switching (gemstone spectral imaging). Two major advantages of DECT are material decomposition by acquiring two image series with different kVp and the elimination of misregistration artifacts. Hounsfield unit measurements by DECT are not absolute and can change depending on the kVp used for an acquisition. Typically, a combination of 80/140 kVp is used for DECT, but for some applications, 100/140 kVp is preferred. In this study, we summarized the clinical applications of DECT and included images that were acquired using the dual-source CT and rapid kVp switching. In general, unenhanced images can be avoided by using DECT for body and neurological applications; iodine can be removed from the image, and a virtual, non-contrast (water) image can be obtained. Neuroradiological applications allow for the removal of bone and calcium from the carotid and brain CT angiography. Thorax applications include perfusion imaging in patients with pulmonary thromboemboli and other chest diseases, xenon ventilation-perfusion imaging and solitary nodule characterization. Cardiac applications include dual-energy cardiac perfusion, viability and cardiac iron detection. The removal of calcific plaques from arteries, bone removal and aortic stent graft evaluation may be achieved in the vascular system. Abdominal applications include the detection and characterization of liver and pancreas masses, the diagnosis of steatosis and iron overload, DECT colonoscopy and CT cholangiography. Urinary system applications are urinary calculi characterization (uric acid vs. non-uric acid), renal cyst characterization and mass characterization. Musculoskeletal applications permit the differentiation of gout from pseudogout and a reduction of metal artifacts. Recent introduction of iterative reconstruction techniques can increase the use of DECT techniques; the use of dual energy in patients with a high BMI is limited due to noise and the radiation dose. DECT may be a good alternative to PET-CT. Iodine map images can quantify iodine uptake, and this approach may be more effective than obtaining non-contrast and post-contrast images for the diagnosis of a solid mass. Thus, computer-aided detection may be used more effectively in CT applications. DECT is a promising technique with potential clinical applications.

  14. A proficiency-based virtual reality endoscopy curriculum improves performance on the fundamentals of endoscopic surgery examination.

    PubMed

    Hashimoto, Daniel A; Petrusa, Emil; Phitayakorn, Roy; Valle, Christina; Casey, Brenna; Gee, Denise

    2018-03-01

    The fundamentals of endoscopic surgery (FES) examination is a national test of knowledge and skill in flexible gastrointestinal endoscopy. The skill portion of the examination involves five tasks that assesses the following skills: scope navigation, loop reduction, mucosal inspection, retroflexion, and targeting. This project aimed to assess the efficacy of a proficiency-based virtual reality (VR) curriculum in preparing residents for the FES skills exam. Experienced (>100 career colonoscopies) and inexperienced endoscopists (<50 career colonoscopies) were recruited to participate. Six VR modules were identified as reflecting the skills tested in the exam. All participants were asked to perform each of the selected modules twice, and median performance was compared between the two groups. Inexperienced endoscopists were subsequently randomized in matched pairs into a repetition (10 repetitions of each task) or proficiency curriculum. After completion of the respective curriculum, FES scores and pass rates were compared to national data and historical institutional control data (endoscopy-rotation training alone). Five experienced endoscopists and twenty-three inexperienced endoscopists participated. Construct valid metrics were identified for six modules and proficiency benchmarks were set at the median performance of experienced endoscopists. FES scores of inexperienced endoscopists in the proficiency group had significantly higher FES scores (530 ± 86) versus historical control (386.7 ± 92.2, p = 0.0003) and higher pass rate (proficiency: 100%, historical control 61.5%, p = 0.01). Trainee engagement in a VR curriculum yields superior FES performance compared to an endoscopy rotation alone. Compared to the 2012-2016 national resident pass rate of 80, 100% of trainees in a proficiency-based curriculum passed the FES manual skills examination.

  15. An Indirect Method to Measure Abutment Screw Preload: A Pilot Study Based on Micro-CT Scanning.

    PubMed

    Rezende, Carlos Eduardo E; Griggs, Jason Alan; Duan, Yuanyuan; Mushashe, Amanda M; Nolasco, Gisele Maria Correr; Borges, Ana Flávia Sanches; Rubo, José Henrique

    2015-01-01

    This study aimed to measure the preload in different implant platform geometries based on micro-CT images. External hexagon (EH) implants and Morse Tapered (MT) implants (n=5) were used for the preload measurement. The abutment screws were scanned in micro-CT to obtain their virtual models, which were used to record their initial length. The abutments were screwed on the implant with a 20 Ncm torque and the set composed by implant, abutment screw and abutment were taken to the micro-CT scanner to obtain virtual slices of the specimens. These slices allowed the measurement of screw lengths after torque application and based on the screw elongation. Preload values were calculated using the Hooke's Law. The preloads of both groups were compared by independent t-test. Removal torque of each specimen was recorded. To evaluate the accuracy of the micro-CT technique, three rods with known lengths were scanned and the length of their virtual model was measured and compared with the original length. One rod was scanned four times to evaluate the measuring method variation. There was no difference between groups for preload (EH = 461.6 N and MT = 477.4 N), but the EH group showed higher removal torque values (13.8 ± 4.7 against 8.2 ± 3.6 N cm for MT group). The micro-CT technique showed a variability of 0.053% and repeatability showed an error of 0.23 to 0.28%. Within the limitations of this study, there was no difference between external hexagon and Morse taper for preload. The method using micro-CT may be considered for preload calculation.

  16. Plot of virtual surgery based on CT medical images

    NASA Astrophysics Data System (ADS)

    Song, Limei; Zhang, Chunbo

    2009-10-01

    Although the CT device can give the doctors a series of 2D medical images, it is difficult to give vivid view for the doctors to acknowledge the decrease part. In order to help the doctors to plot the surgery, the virtual surgery system is researched based on the three-dimensional visualization technique. After the disease part of the patient is scanned by the CT device, the 3D whole view will be set up based on the 3D reconstruction module of the system. TCut a part is the usually used function for doctors in the real surgery. A curve will be created on the 3D space; and some points can be added on the curve automatically or manually. The position of the point can change the shape of the cut curves. The curve can be adjusted by controlling the points. If the result of the cut function is not satisfied, all the operation can be cancelled to restart. The flexible virtual surgery gives more convenience to the real surgery. Contrast to the existing medical image process system, the virtual surgery system is added to the system, and the virtual surgery can be plotted for a lot of times, till the doctors have enough confidence to start the real surgery. Because the virtual surgery system can give more 3D information of the disease part, some difficult surgery can be discussed by the expert doctors in different city via internet. It is a useful function to understand the character of the disease part, thus to decrease the surgery risk.

  17. Computer-assisted polyp matching between optical colonoscopy and CT colonography: a phantom study

    NASA Astrophysics Data System (ADS)

    Roth, Holger R.; Hampshire, Thomas E.; Helbren, Emma; Hu, Mingxing; Vega, Roser; Halligan, Steve; Hawkes, David J.

    2014-03-01

    Potentially precancerous polyps detected with CT colonography (CTC) need to be removed subsequently, using an optical colonoscope (OC). Due to large colonic deformations induced by the colonoscope, even very experienced colonoscopists find it difficult to pinpoint the exact location of the colonoscope tip in relation to polyps reported on CTC. This can cause unduly prolonged OC examinations that are stressful for the patient, colonoscopist and supporting staff. We developed a method, based on monocular 3D reconstruction from OC images, that automatically matches polyps observed in OC with polyps reported on prior CTC. A matching cost is computed, using rigid point-based registration between surface point clouds extracted from both modalities. A 3D printed and painted phantom of a 25 cm long transverse colon segment was used to validate the method on two medium sized polyps. Results indicate that the matching cost is smaller at the correct corresponding polyp between OC and CTC: the value is 3.9 times higher at the incorrect polyp, comparing the correct match between polyps to the incorrect match. Furthermore, we evaluate the matching of the reconstructed polyp from OC with other colonic endoluminal surface structures such as haustral folds and show that there is a minimum at the correct polyp from CTC. Automated matching between polyps observed at OC and prior CTC would facilitate the biopsy or removal of true-positive pathology or exclusion of false-positive CTC findings, and would reduce colonoscopy false-negative (missed) polyps. Ultimately, such a method might reduce healthcare costs, patient inconvenience and discomfort.

  18. [Virtual bronchoscopy in the child using multi-slice CT: initial clinical experiences].

    PubMed

    Kirchner, J; Laufer, U; Jendreck, M; Kickuth, R; Schilling, E M; Liermann, D

    2000-01-01

    Virtual bronchoscopy of the pediatric patient has been reported to be more difficult because of artifacts due to breathing or motion. We demonstrate the benefit of the accelerated examination based on multislice spiral CT (MSCT) in the pediatric patient which has not been reported so far. MSCT (tube voltage 120 kV, tube current 110 mA, 4 x 1 mm Slice thickness, 500 ms rotation time, Pitch 6) was performed on a CT scanner of the latest generation (Volume Zoom, Siemens Corp. Forchheim, Germany). In totally we examined 11 patients (median age 48 months, range 2-122 months) suspected of having tracheoesophageal fistula (n = 2), tracheobronchial narrowing (n = 8) due to intrinsic or extrinsic factors or injury of the bronchial system (n = 1). In all patients we obtained sufficient data for 3D reconstruction avoiding general anesthesia. 6/11 examinations were described to be without pathological finding. A definite diagnosis was obtained in 10 patients. Virtual bronchoscopy could avoid other invasive diagnostic examination in 8/11 patients (73%). Helical CT provides 3D-reconstruction and virtual bronchoscopy in the newborn as well as the infant. It avoids additional diagnostic bronchoscopy in a high percentage of all cases.

  19. Distributed computing methodology for training neural networks in an image-guided diagnostic application.

    PubMed

    Plagianakos, V P; Magoulas, G D; Vrahatis, M N

    2006-03-01

    Distributed computing is a process through which a set of computers connected by a network is used collectively to solve a single problem. In this paper, we propose a distributed computing methodology for training neural networks for the detection of lesions in colonoscopy. Our approach is based on partitioning the training set across multiple processors using a parallel virtual machine. In this way, interconnected computers of varied architectures can be used for the distributed evaluation of the error function and gradient values, and, thus, training neural networks utilizing various learning methods. The proposed methodology has large granularity and low synchronization, and has been implemented and tested. Our results indicate that the parallel virtual machine implementation of the training algorithms developed leads to considerable speedup, especially when large network architectures and training sets are used.

  20. Virtual reality colonoscopy simulation: a compulsory practice for the future colonoscopist?

    PubMed

    Ahlberg, G; Hultcrantz, R; Jaramillo, E; Lindblom, A; Arvidsson, D

    2005-12-01

    As for any manual procedure, the learning curves for medical interventions can have undesirable phases, occurring mostly in the early experience of applying a technique. There have been impressive advances in endoscopic procedures during recent years, and there is an emerging trend that the number of procedures is increasing in parallel with these. In addition, the introduction of screening programs for colorectal cancer will also increase the numbers of procedures needed. Recent developments in medical simulation seem promising with regard to the possibility of "training out" undesirable parts of the learning curve outside the operating room. The aim of this study was to investigate whether the use of the AccuTouch flexible endoscopy simulator improves the early part of the learning curve in colonoscopy training. 12 endoscopy trainees, 10 surgeons and two medical gastroenterologists, all with experience in gastroscopy but with no specific colonoscopy experience, were randomly assigned to either simulator training or to a control group. They all received the same theoretical study package and the training group practiced with the AccuTouch colonoscopy simulator until a predefined expert level of performance was reached. All trainees performed their first ten individual colonoscopies described in detail in a separate protocol. Trainees in the simulator-trained group performed significantly better (P=0.0011) and managed to reach the cecum in 52% of their cases (vs. 19% in the control group), and were 4.53 times more likely to succeed compared with the controls. Additionally, there was a significantly shorter procedure time and less patient discomfort in the hands of the simulator-trained group. Skills acquired using the AccuTouch simulator transfer well into the clinical colonoscopy environment. The results of this trial clearly support the plan to integrate simulator training into endoscopic education curricula.

  1. Life-threatening gastrointestinal system bleeding in Hodgkin disease: multidetector CT findings and review of the literature.

    PubMed

    Akpinar, Erhan; Türkbey, Bariş; Cil, Barbaros Erhan; Canyiğit, Murat; Dündar, Ziya; Balkanci, Ferhun

    2007-06-01

    Acute lower gastrointestinal system (GIS) bleeding is a life-threatening condition. Immediate determination of the origin of the bleeding is crucial, since hemostatic management must be initiated as rapidly as possible. Colonoscopy, radionuclide studies, and conventional angiography are considered the most important methods for assessing the origin of the bleeding. There are few published reports about the feasibility of computed tomography (CT) in acute GIS bleeding. We present multidetector CT (MDCT) findings in a case of Hodgkin disease status one month post-chemotherapy (CHOP protocol; cyclophosphamide, doxorubicin, vincristine, prednisone) that presented with acute lower GIS bleeding.

  2. An Unusual Clinical Presentation of Gastrointestinal Metastasis From Invasive Lobular Carcinoma of Breast.

    PubMed

    Balakrishnan, Bathmapriya; Shaik, Sufiya; Burman-Solovyeva, Irina

    2016-01-01

    Introduction. We present an unusual case of metastatic lobular breast carcinoma. Typical areas of metastasis include bone, gynecological organs, peritoneum, retroperitoneum, and gastrointestinal (GI) tract, in order of frequency. With regard to GI metastasis, extrahepatic represents a rare site. Case. Two years after being diagnosed with invasive lobular breast carcinoma, a 61-year-old female complained of 3 months of nonspecific abdominal pain and diarrhea. A colonoscopy revealed 5 tubular adenomatous polyps in the ascending and transverse colon. Contrast computed tomography (CT) of the abdomen and pelvis was done 7 months after the colonoscopy to further evaluate persistent diarrhea. The CT results were consistent with infectious or inflammatory enterocolitis. Despite conservative management, symptoms failed to improve and a repeat diagnostic colonoscopy was obtained. Random colonic biopsies revealed metastatic high-grade adenocarcinoma of the colon. Discussion. Metastatic lobular breast carcinoma to the GI tract can distort initial interpretation of endoscopic evaluation with lesions mimicking inflammation. The interval between discovery of GI metastasis and diagnosis of lobular breast cancer can vary widely from synchronous to 30 years; however, progression is most often much sooner. Nonspecific symptoms and subtle appearance of metastatic lesions may confound the diagnosis. A high index of suspicion is needed for possible metastatic spread to the GI tract in patients with a history of invasive lobular breast carcinoma. Perhaps, patients with nonspecific GI symptoms should have an endoscopic examination with multiple random biopsies as invasive lobular carcinoma typically mimics macroscopic changes consistent with colitis.

  3. Business plan to establish a CT colonography service.

    PubMed

    Fajardo, Laurie L; Hurley, James P; Brown, Bruce P; Summers, Robert W; McDaniel, R Donald

    2006-03-01

    The authors describe the University of Iowa Department of Radiology's business planning process to initiate a new service in computed tomographic colonography (CTC). Also known as virtual colonoscopy, CTC is a noninvasive technology that offers less risk, and potentially similar sensitivity and specificity, than conventional optical colonoscopy (OC). Although not currently covered by all insurance payers, about a year ago, the Centers for Medicare and Medicaid Services instituted temporary Current Procedural Terminology codes (Category III) for CTC. In locales where the procedure is not covered by insurers, it is likely to be sought by patients willing to pay out of pocket to undergo noninvasive cancer screening as an alternative to OC. Thus, CTC could become the preferred method of colon cancer surveillance by insurance providers in the near future. In developing the business plan, the authors reviewed pertinent scientific and clinical data to evaluate the need for and efficacy of CTC. Local market data were used to estimate patient and procedure volumes and utilization. The authors modeled financial expectations with respect to return on investment on the basis of recently reported models specific to CTC, resource requirements, and the operational impact of the new service on existing hospital and departmental clinical functions. Because there are few local providers of CTC in the authors' region, the business plan also included a publicity campaign and plan to market the new service, stimulate general public interest early, and differentiate the program as a leader in applying this unique new technology to promote cancer screening. Finally, the planning committee acknowledged and accommodated needs specific to the missions of an academic medical center with respect to research and education in designing the new service.

  4. Fluid tagging for CT colonography: effectiveness of a 2-hour iodinated oral preparation after incomplete optical colonoscopy.

    PubMed

    Chang, Kevin J; Rekhi, Satinder S; Anderson, Stephan W; Soto, Jorge A

    2011-01-01

    To evaluate the distal extent and attenuation of bowel opacification achieved after administration of a single low volume dose of oral contrast 2 hours before computed tomographic colonography (CTC) after incomplete optical colonoscopy. This retrospective study included 144 patients undergoing CTC after incomplete colonoscopy from April 2006 to July 2008 at 2 separate medical centers. Each patient received 20 to 30 mL of diatrizoate meglumine and diatrizoate sodium solution 2 hours before being scanned. The distalmost extent of opacification was: stomach/small bowel, n = 13; cecum, n = 2; ascending colon, n = 7; transverse colon, n = 19; descending colon, n = 14; sigmoid colon, n = 24; rectum, n = 65. The mean attenuation of each opacified segment was: cecum, 449 Hounsfield units (HU); ascending colon, 474 HU; transverse colon, 468 HU; descending colon, 421 HU; sigmoid colon, 391 HU; and rectum, 382 HU. In 103 (71.5%) patients, oral contrast reached the distal colon (descending colon, sigmoid colon, or rectum). The oral contrast did not reach the colon in only 13 (9.0%) patients. Oral administration of a small volume hyperosmolar oral contrast agent 2 hours before CTC results in satisfactory colonic opacification in the majority of patients. Adding same-day fluid tagging in incomplete colonoscopy patients presenting for completion CTC should result in adequate fluid opacification for most of the colon, especially proximal segments not visualized at the time of incomplete colonoscopy.

  5. Analysis of scalability of high-performance 3D image processing platform for virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Yoshida, Hiroyuki; Wu, Yin; Cai, Wenli

    2014-03-01

    One of the key challenges in three-dimensional (3D) medical imaging is to enable the fast turn-around time, which is often required for interactive or real-time response. This inevitably requires not only high computational power but also high memory bandwidth due to the massive amount of data that need to be processed. For this purpose, we previously developed a software platform for high-performance 3D medical image processing, called HPC 3D-MIP platform, which employs increasingly available and affordable commodity computing systems such as the multicore, cluster, and cloud computing systems. To achieve scalable high-performance computing, the platform employed size-adaptive, distributable block volumes as a core data structure for efficient parallelization of a wide range of 3D-MIP algorithms, supported task scheduling for efficient load distribution and balancing, and consisted of a layered parallel software libraries that allow image processing applications to share the common functionalities. We evaluated the performance of the HPC 3D-MIP platform by applying it to computationally intensive processes in virtual colonoscopy. Experimental results showed a 12-fold performance improvement on a workstation with 12-core CPUs over the original sequential implementation of the processes, indicating the efficiency of the platform. Analysis of performance scalability based on the Amdahl's law for symmetric multicore chips showed the potential of a high performance scalability of the HPC 3DMIP platform when a larger number of cores is available.

  6. Participation in colorectal cancer screening trials after first-time invitation: a systematic review.

    PubMed

    Khalid-de Bakker, C; Jonkers, D; Smits, K; Mesters, I; Masclee, A; Stockbrügger, R

    2011-12-01

    Colorectal cancer (CRC) screening is implemented by an increasing number of countries. Participation rates of screening programs influence the health benefit and cost-effectiveness of the applied method. The aim was to systematically review participation rate after first-time invitation for CRC screening with fecal occult blood test (FOBT), sigmoidoscopy, colonoscopy, and/or computed tomography (CT) colonography. A systematic literature search was performed prior to October 1 2009. Prospective CRC screening studies of unselected populations reporting participation rates were included. After meta-analyses, overall participation rates were found to be 47 % for FOBT, 42 % for fecal immunologic tests (FITs), 35 % for sigmoidoscopy, 41 % for sigmoidoscopy combined with FIT/FOBT, 28 % for colonoscopy, and 22 % for CT colonography. Studies comparing screening methods showed higher participation rates for less invasive methods. Studies comparing invitation methods showed higher participation rates with general practitioner involvement, a more personalized recruitment approach, and reduction of barriers that discourage participation. Knowledge of identified factors affecting CRC screening participation can be used to improve screening programs. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Real-time fusion of endoscopic views with dynamic 3-D cardiac images: a phantom study.

    PubMed

    Szpala, Stanislaw; Wierzbicki, Marcin; Guiraudon, Gerard; Peters, Terry M

    2005-09-01

    Minimally invasive robotically assisted cardiac surgical systems currently do not routinely employ 3-D image guidance. However, preoperative magnetic resonance and computed tomography (CT) images have the potential to be used in this role, if appropriately registered with the patient anatomy and animated synchronously with the motion of the actual heart. This paper discusses the fusion of optical images of a beating heart phantom obtained from an optically tracked endoscope, with volumetric images of the phantom created from a dynamic CT dataset. High quality preoperative dynamic CT images are created by first extracting the motion parameters of the heart from the series of temporal frames, and then applying this information to animate a high-quality heart image acquired at end systole. Temporal synchronization of the endoscopic and CT model is achieved by selecting the appropriate CT image from the dynamic set, based on an electrocardiographic trigger signal. The spatial error between the optical and virtual images is 1.4 +/- 1.1 mm, while the time discrepancy is typically 50-100 ms. Index Terms-Image guidance, image warping, minimally invasive cardiac surgery, virtual endoscopy, virtual reality.

  8. Development and Testing of an Automated 4-Day Text Messaging Guidance as an Aid for Improving Colonoscopy Preparation.

    PubMed

    Walter, Benjamin Michael; Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan

    2016-06-21

    In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective of this study was to assess the function of an automated text messaging (short message service, SMS)-supported colonoscopy preparation starting 4 days before colonoscopy appointment. After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging-provided information assessed by a questionnaire. Web-based SMS text messaging-supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging-based information was high. Using SMS for colonoscopy preparation with 4 days' guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy preparation was sufficient and patients were highly satisfied with the system during colonoscopy preparation.

  9. Development and Testing of an Automated 4-Day Text Messaging Guidance as an Aid for Improving Colonoscopy Preparation

    PubMed Central

    Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan

    2016-01-01

    Background In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective Objective of this study was to assess the function of an automated text messaging (short message service, SMS)–supported colonoscopy preparation starting 4 days before colonoscopy appointment. Methods After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging–provided information assessed by a questionnaire. Results Web-based SMS text messaging–supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging–based information was high. Conclusions Using SMS for colonoscopy preparation with 4 days’ guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy preparation was sufficient and patients were highly satisfied with the system during colonoscopy preparation. PMID:27329204

  10. Development and validation of an algorithm to complete colonoscopy using standard endoscopes in patients with prior incomplete colonoscopy

    PubMed Central

    Rogers, Melinda C.; Gawron, Andrew; Grande, David; Keswani, Rajesh N.

    2017-01-01

    Background and study aims  Incomplete colonoscopy may occur as a result of colon angulation (adhesions or diverticulosis), endoscope looping, or both. Specialty endoscopes/devices have been shown to successfully complete prior incomplete colonoscopies, but may not be widely available. Radiographic or other image-based evaluations have been shown to be effective but may miss small or flat lesions, and colonoscopy is often still indicated if a large lesion is identified. The purpose of this study was to develop and validate an algorithm to determine the optimum endoscope to ensure completion of the examination in patients with prior incomplete colonoscopy. Patients and methods  This was a prospective cohort study of 175 patients with prior incomplete colonoscopy who were referred to a single endoscopist at a single academic medical center over a 3-year period from 2012 through 2015. Colonoscopy outcomes from the initial 50 patients were used to develop an algorithm to determine the optimal standard endoscope and technique to achieve cecal intubation. The algorithm was validated on the subsequent 125 patients. Results  The overall repeat colonoscopy success rate using a standard endoscope was 94 %. The initial standard endoscope specified by the algorithm was used and completed the colonoscopy in 90 % of patients. Conclusions  This study identifies an effective strategy for completing colonoscopy in patients with prior incomplete examination, using widely available standard endoscopes and an algorithm based on patient characteristics and reasons for prior incomplete colonoscopy. PMID:28924595

  11. [Development of a software for 3D virtual phantom design].

    PubMed

    Zou, Lian; Xie, Zhao; Wu, Qi

    2014-02-01

    In this paper, we present a 3D virtual phantom design software, which was developed based on object-oriented programming methodology and dedicated to medical physics research. This software was named Magical Phan tom (MPhantom), which is composed of 3D visual builder module and virtual CT scanner. The users can conveniently construct any complex 3D phantom, and then export the phantom as DICOM 3.0 CT images. MPhantom is a user-friendly and powerful software for 3D phantom configuration, and has passed the real scene's application test. MPhantom will accelerate the Monte Carlo simulation for dose calculation in radiation therapy and X ray imaging reconstruction algorithm research.

  12. Inter-algorithm lesion volumetry comparison of real and 3D simulated lung lesions in CT

    NASA Astrophysics Data System (ADS)

    Robins, Marthony; Solomon, Justin; Hoye, Jocelyn; Smith, Taylor; Ebner, Lukas; Samei, Ehsan

    2017-03-01

    The purpose of this study was to establish volumetric exchangeability between real and computational lung lesions in CT. We compared the overall relative volume estimation performance of segmentation tools when used to measure real lesions in actual patient CT images and computational lesions virtually inserted into the same patient images (i.e., hybrid datasets). Pathologically confirmed malignancies from 30 thoracic patient cases from Reference Image Database to Evaluate Therapy Response (RIDER) were modeled and used as the basis for the comparison. Lesions included isolated nodules as well as those attached to the pleura or other lung structures. Patient images were acquired using a 16 detector row or 64 detector row CT scanner (Lightspeed 16 or VCT; GE Healthcare). Scans were acquired using standard chest protocols during a single breath-hold. Virtual 3D lesion models based on real lesions were developed in Duke Lesion Tool (Duke University), and inserted using a validated image-domain insertion program. Nodule volumes were estimated using multiple commercial segmentation tools (iNtuition, TeraRecon, Inc., Syngo.via, Siemens Healthcare, and IntelliSpace, Philips Healthcare). Consensus based volume comparison showed consistent trends in volume measurement between real and virtual lesions across all software. The average percent bias (+/- standard error) shows -9.2+/-3.2% for real lesions versus -6.7+/-1.2% for virtual lesions with tool A, 3.9+/-2.5% and 5.0+/-0.9% for tool B, and 5.3+/-2.3% and 1.8+/-0.8% for tool C, respectively. Virtual lesion volumes were statistically similar to those of real lesions (< 4% difference) with p >.05 in most cases. Results suggest that hybrid datasets had similar inter-algorithm variability compared to real datasets.

  13. Computed tomography-based virtual colonoscopy in the assessment of bowel endometriosis: The surgeon's point of view.

    PubMed

    Roman, H; Carilho, J; Da Costa, C; De Vecchi, C; Suaud, O; Monroc, M; Hochain, P; Vassilieff, M; Savoye-Collet, C; Saint-Ghislain, M

    2016-01-01

    To discuss the role of computed tomography-based virtual colonoscopy (CTC) in preoperative assessment of bowel endometriosis. Retrospective study using data prospectively recorded, including 127 patients with colorectal endometriosis, having undergone CTC for bowel endometriosis. The study was conducted in a tertiary referral center during 38 consecutive months. Preoperative assessment included CTC, magnetic resonance imaging (MRI), endorectal ultrasound (ERUS) and clinical examination. Information concerning identification of deep infiltrating endometriosis (DIE) of the bowel, the length and height of colorectal involvement, stenosis of digestive lumen and associated digestive localizations were compared with intraoperative findings. Sensitivity and specificity of CTC for DIE of the rectum, the sigmoid colon, associated digestive localizations, and stenosis of the digestive lumen were respectively 97% and 84%, 93% and 88%, 84% and 97%, 96% and 96%. Intraoperative estimation of the length of digestive tract involved by DIE was closer to that provided by CTC than those provided by MRI and ERUS. When CTC revealed stenosis of digestive lumen, higher rates of colorectal resection (63% vs. 9.6%, < 0.001) and disc excision (25.9% vs. 11%, 0.03) were recorded. For those surgeons using various procedures for management of bowel endometriosis, accurate information on the length and height of bowel involvement, as well as the existence of bowel stenosis enables informed decision regarding the feasibility of conservative techniques versus bowel resection. Preoperative identification of associated localizations above the sigmoid colon is another major advantage related to CTC. CTC provides accurate data on the length and height of colorectal involvement by DIE, stenosis of digestive lumen and associated lesions of digestive tract, which impact on the choice of surgical procedure. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. Clinical case management and navigation for colonoscopy screening in an academic medical center.

    PubMed

    Cavanagh, Mary F; Lane, Dorothy S; Messina, Catherine R; Anderson, Joseph C

    2013-08-01

    One of 5 nationally funded Centers for Disease Control and Prevention Colorectal Cancer (CRC) Screening Demonstration Programs, Project SCOPE, was conducted at an academic medical center and provided colonoscopy screening at no cost to underserved minority patients from local community health centers. Established barriers to CRC screening (eg, financial, language, transportation) among the target population were addressed through clinical coordination of care by key project staff. The use of a clinician with a patient navigator allowed for the performance of precolonoscopy "telephone visits" instead of office visits to the gastroenterologist in virtually all patients. The clinician elicited information relevant to making screening decisions (eg, past medical and surgical history, focused review of systems, medication/supplement use, CRC screening history). The patient navigator reduced barriers, including, but not limited to, scheduling, transportation, and physical navigation of the medical center on the day of colonoscopy. Preprogram preparation was vital in laying groundwork for the project, yet enhancements to the program were ongoing throughout the screening period. Detailed referral forms from primary care physicians, coupled with information obtained during telephone interviews, facilitated high colonoscopy completion rates and excellent patient satisfaction. Similarly valuable was the employment of a bilingual patient navigator, who provided practical and emotional patient support. Academic medical centers can be efficient models for providing CRC screening to disadvantaged populations. Coordination of care by a preventive medicine department, directing the recruitment, scheduling, prescreening education, and the evaluation and preparation of target populations had an overall positive effect on CRC screening with colonoscopy among patients from a community health center. © 2013 American Cancer Society.

  15. [Virtual otoscopy--technique, indications and initial experiences with multislice spiral CT].

    PubMed

    Klingebiel, R; Bauknecht, H C; Lehmann, R; Rogalla, P; Werbs, M; Behrbohm, H; Kaschke, O

    2000-11-01

    We report the standardized postprocessing of high-resolution CT data acquired by incremental CT and multi-slice CT in patients with suspected middle ear disorders to generate three-dimensional endoluminal views known as virtual otoscopy. Subsequent to the definition of a postprocessing protocol, standardized endoluminal views of the middle ear were generated according to their otological relevance. The HRCT data sets of 26 ENT patients were transferred to a workstation and postprocessed to 52 virtual otoscopies. Generation of predefined endoluminal views from the HRCT data sets was possible in all patients. Virtual endoscopic views added meaningful information to the primary cross-sectional data in patients suffering from ossicular pathology, having contraindications for invasive tympanic endoscopy or being assessed for surgery of the tympanic cavity. Multi slice CT improved the visualization of subtle anatomic details such as the stapes suprastructure and reduced the scanning time. Virtual endoscopy allows for the non invasive endoluminal visualization of various tympanic lesions. Use of the multi-slice CT technique reduces the scanning time and improves image quality in terms of detail resolution.

  16. CT Arthrography and Virtual Arthroscopy in the Diagnosis of the Anterior Cruciate Ligament and Meniscal Abnormalities of the Knee Joint

    PubMed Central

    Lee, Whal; Kim, Ho Sung; Kim, Seok Jung; Kim, Hyung Ho; Chung, Jin Wook; Kang, Heung Sik; Choi, Ja-Young

    2004-01-01

    Objective To determine the diagnostic accuracy of CT arthrography and virtual arthroscopy in the diagnosis of anterior cruciate ligament and meniscus pathology. Materials and Methods Thirty-eight consecutive patients who underwent CT arthrography and arthroscopy of the knee were included in this study. The ages of the patients ranged from 19 to 52 years and all of the patients were male. Sagittal, coronal, transverse and oblique coronal multiplanar reconstruction images were reformatted from CT arthrography. Virtual arthroscopy was performed from 6 standard views using a volume rendering technique. Three radiologists analyzed the MPR images and two orthopedic surgeons analyzed the virtual arthroscopic images. Results The sensitivity and specificity of CT arthrography for the diagnosis of anterior cruciate ligament abnormalities were 87.5%-100% and 93.3-96.7%, respectively, and those for meniscus abnormalities were 91.7%-100% and 98.1%, respectively. The sensitivity and specificity of virtual arthroscopy for the diagnosis of anterior cruciate ligament abnormalities were 87.5% and 83.3-90%, respectively, and those for meniscus abnormalities were 83.3%-87.5% and 96.1-98.1%, respectively. Conclusion CT arthrography and virtual arthroscopy showed good diagnostic accuracy for anterior cruciate ligament and meniscal abnormalities. PMID:15064559

  17. Correlation Between Findings of Multislice Helical Computed Tomography (CT), Endoscopic Examinations, Endovascular Procedures, and Surgery in Patients with Symptoms of Acute Gastrointestinal Bleeding.

    PubMed

    Konecki, Dariusz; Grabowska-Derlatka, Laretta; Pacho, Ryszard; Rowiński, Olgierd

    2017-01-01

    Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding.

  18. Evidence-based recommendations for bowel cleansing before colonoscopy in children: a report from a national working group.

    PubMed

    Turner, D; Levine, A; Weiss, B; Hirsh, A; Shamir, R; Shaoul, R; Berkowitz, D; Bujanover, Y; Cohen, S; Eshach-Adiv, O; Jamal, Gera; Kori, M; Lerner, A; On, A; Rachman, L; Rosenbach, Y; Shamaly, H; Shteyer, E; Silbermintz, A; Yerushalmi, B

    2010-12-01

    There are no current recommendations for bowel cleansing before colonoscopy in children. The Israeli Society of Pediatric Gastroenterology and Nutrition (ISPGAN) established an iterative working group to formulate evidence-based guidelines for bowel cleansing in children prior to colonoscopy. Data were collected by systematic review of the literature and via a national-based survey of all endoscopy units in Israel. Based on the strength of evidence, the Committee reached consensus on six recommended protocols in children. Guidelines were finalized after an open audit of ISPGAN members. Data on 900 colonoscopies per year were accrued, which represents all annual pediatric colonoscopies performed in Israel. Based on the literature review, the national survey, and the open audit, several age-stratified pediatric cleansing protocols were proposed: two PEG-ELS protocols (polyethylene-glycol with electrolyte solution); Picolax-based protocol (sodium picosulphate with magnesium citrate); sodium phosphate protocol (only in children over the age of 12 years who are at low risk for renal damage); stimulant laxative-based protocol (e. g. bisacodyl); and a PEG 3350-based protocol. A population-based analysis estimated that the acute toxicity rate of oral sodium phosphate is at most 3/7320 colonoscopies (0.041 %). Recommendations on diet and enema use are provided in relation to each proposed protocol. There is no ideal bowel cleansing regimen and, thus, various protocols are in use. We propose several evidence-based protocols to optimize bowel cleansing in children prior to colonoscopy and minimize adverse events. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Correlation between adenoma detection rate in colonoscopy- and fecal immunochemical testing-based colorectal cancer screening programs.

    PubMed

    Cubiella, Joaquín; Castells, Antoni; Andreu, Montserrat; Bujanda, Luis; Carballo, Fernando; Jover, Rodrigo; Lanas, Ángel; Morillas, Juan Diego; Salas, Dolores; Quintero, Enrique

    2017-03-01

    The adenoma detection rate (ADR) is the main quality indicator of colonoscopy. The ADR recommended in fecal immunochemical testing (FIT)-based colorectal cancer screening programs is unknown. Using the COLONPREV (NCT00906997) study dataset, we performed a post-hoc analysis to determine if there was a correlation between the ADR in primary and work-up colonoscopy, and the equivalent figure to the minimal 20% ADR recommended. Colonoscopy was performed in 5722 individuals: 5059 as primary strategy and 663 after a positive FIT result (OC-Sensor™; cut-off level 15 µg/g of feces). We developed a predictive model based on a multivariable lineal regression analysis including confounding variables. The median ADR was 31% (range, 14%-51%) in the colonoscopy group and 55% (range, 21%-83%) in the FIT group. There was a positive correlation in the ADR between primary and work-up colonoscopy (Pearson's coefficient 0.716; p  < 0.001). ADR in the FIT group was independently related to ADR in the colonoscopy group: regression coefficient for colonoscopy ADR, 0.71 ( p  = 0.009); sex, 0.09 ( p  = 0.09); age, 0.3 ( p  = 0.5); and region 0.00 ( p  = 0.9). The equivalent figure to the 20% ADR was 45% (95% confidence interval, 35%-56%). ADR in primary and work-up colonoscopy of a FIT-positive result are positively and significantly correlated.

  20. Correlation between adenoma detection rate in colonoscopy- and fecal immunochemical testing-based colorectal cancer screening programs

    PubMed Central

    Castells, Antoni; Andreu, Montserrat; Bujanda, Luis; Carballo, Fernando; Jover, Rodrigo; Lanas, Ángel; Morillas, Juan Diego; Salas, Dolores; Quintero, Enrique

    2016-01-01

    Background The adenoma detection rate (ADR) is the main quality indicator of colonoscopy. The ADR recommended in fecal immunochemical testing (FIT)-based colorectal cancer screening programs is unknown. Methods Using the COLONPREV (NCT00906997) study dataset, we performed a post-hoc analysis to determine if there was a correlation between the ADR in primary and work-up colonoscopy, and the equivalent figure to the minimal 20% ADR recommended. Colonoscopy was performed in 5722 individuals: 5059 as primary strategy and 663 after a positive FIT result (OC-Sensor™; cut-off level 15 µg/g of feces). We developed a predictive model based on a multivariable lineal regression analysis including confounding variables. Results The median ADR was 31% (range, 14%–51%) in the colonoscopy group and 55% (range, 21%–83%) in the FIT group. There was a positive correlation in the ADR between primary and work-up colonoscopy (Pearson’s coefficient 0.716; p < 0.001). ADR in the FIT group was independently related to ADR in the colonoscopy group: regression coefficient for colonoscopy ADR, 0.71 (p = 0.009); sex, 0.09 (p = 0.09); age, 0.3 (p = 0.5); and region 0.00 (p = 0.9). The equivalent figure to the 20% ADR was 45% (95% confidence interval, 35%–56%). Conclusions ADR in primary and work-up colonoscopy of a FIT-positive result are positively and significantly correlated. PMID:28344793

  1. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses.

    PubMed

    Wellenberg, R H H; Boomsma, M F; van Osch, J A C; Vlassenbroek, A; Milles, J; Edens, M A; Streekstra, G J; Slump, C H; Maas, M

    2017-03-01

    To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector Spectral CT scanner at 120-kVp and 140-kVp at a standard computed tomography dose index of 20.0mGy. Several unilateral and bilateral hip prostheses consisting of different metal alloys were inserted and combined which were surrounded by 18 hydroxyapatite calcium carbonate pellets representing bone. Images were reconstructed with iterative reconstruction and analysed at monochromatic energies ranging from 40 to 200keV. CT numbers in Hounsfield Units (HU), noise measured as the standard deviation in HU, signal-to-noise-ratios (SNRs) and contrast-to-noise-ratios (CNRs) were analysed within fixed regions-of-interests placed in and around the pellets. In 70 and 74keV virtual monochromatic images the CT numbers of the pellets were similar to 120-kVp and 140-kVp polychromatic results, therefore serving as reference. A separation into three categories of metal artefacts was made (no, mild/moderate and severe) where pellets were categorized based on HU deviations. At high keV values overall image contrast was reduced. For mild/moderate artefacts, the highest average CNRs were attained with virtual monochromatic 130keV images, acquired at 140-kVp. Severe metal artefacts were not reduced. In 130keV images, only mild/moderate metal artefacts were significantly reduced compared to 70 and 74keV images. Deviations in CT numbers, noise, SNRs and CNRs due to metal artefacts were decreased with respectively 64%, 57%, 62% and 63% (p<0.001) compared to unaffected pellets. Optimal keVs, based on CNRs, for different unilateral and bilateral metal hip prostheses consisting of different metal alloys varied from 74 to 150keV. The Titanium alloy resulted in less severe artefacts and were reduced more effectively compared to the Cobalt alloy. Virtual monochromatic dual-layer Spectral CT imaging results in a significant reduction of streak artefacts produced by beam-hardening in mild and moderate artefacts by improving CT number accuracy, SNRs and CNRs, while decreasing noise values in a total hip arthroplasty phantom. An optimal monochromatic energy of 130keV was found ranging from 74keV to 150keV for different unilateral and bilateral hip prostheses consisting of different metal alloys. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  2. Development of virtual patient models for permanent implant brachytherapy Monte Carlo dose calculations: interdependence of CT image artifact mitigation and tissue assignment.

    PubMed

    Miksys, N; Xu, C; Beaulieu, L; Thomson, R M

    2015-08-07

    This work investigates and compares CT image metallic artifact reduction (MAR) methods and tissue assignment schemes (TAS) for the development of virtual patient models for permanent implant brachytherapy Monte Carlo (MC) dose calculations. Four MAR techniques are investigated to mitigate seed artifacts from post-implant CT images of a homogeneous phantom and eight prostate patients: a raw sinogram approach using the original CT scanner data and three methods (simple threshold replacement (STR), 3D median filter, and virtual sinogram) requiring only the reconstructed CT image. Virtual patient models are developed using six TAS ranging from the AAPM-ESTRO-ABG TG-186 basic approach of assigning uniform density tissues (resulting in a model not dependent on MAR) to more complex models assigning prostate, calcification, and mixtures of prostate and calcification using CT-derived densities. The EGSnrc user-code BrachyDose is employed to calculate dose distributions. All four MAR methods eliminate bright seed spot artifacts, and the image-based methods provide comparable mitigation of artifacts compared with the raw sinogram approach. However, each MAR technique has limitations: STR is unable to mitigate low CT number artifacts, the median filter blurs the image which challenges the preservation of tissue heterogeneities, and both sinogram approaches introduce new streaks. Large local dose differences are generally due to differences in voxel tissue-type rather than mass density. The largest differences in target dose metrics (D90, V100, V150), over 50% lower compared to the other models, are when uncorrected CT images are used with TAS that consider calcifications. Metrics found using models which include calcifications are generally a few percent lower than prostate-only models. Generally, metrics from any MAR method and any TAS which considers calcifications agree within 6%. Overall, the studied MAR methods and TAS show promise for further retrospective MC dose calculation studies for various permanent implant brachytherapy treatments.

  3. Prevalence of advanced adenomas in small and diminutive colon polyps using direct measurement of size.

    PubMed

    Tsai, Franklin C; Strum, Williamson B

    2011-08-01

    Most studies reporting polyp size use visual estimates. Determining the prevalence of advanced histology based on direct measurement of polyp size may help guide the management of polyps found at optical colonoscopy (OC) and CT colonography (CTC). We designed a large, prospective study to assess the prevalence of advanced adenomas based on direct measurement of polyp size by a certified pathologists' assistant as reported in the pathology report. Patients between 40 and 89 years of age who presented for screening colonoscopy were included in our study. Advanced adenomas were defined as ≥10 mm or ≥25% villous features, high grade dysplasia or cancer. Polyps were divided by size into three groups: diminutive (≤5 mm), small (6-9 mm) and large (≥10 mm). If more than one adenoma was present, the most advanced was used for analysis. We evaluated 6,905 consecutive patients referred for colonoscopy between January 2005 and December 2006. Of the 4,967 who met the inclusion criteria, the mean age was 58.8 and consisted of 59% women. Overall, 930 (18.7%) had an adenoma; 248 (5%) were advanced adenomas including 8 (0.16%) cancers. Of 89 polyps≥10 mm, 76 (85%) had advanced histology; of 247 polyps 6-9 mm, 67 (27%) were advanced; of 1,025 polyps ≤5 mm, 105 (10%) were advanced. Thus, 172 of 248 (69%) patients with advanced adenomas had small or diminutive adenomas. Our data indicate the majority (69%) of advanced adenomas are <10 mm. Even among polyps≤5 mm, there was an appreciable prevalence of advanced adenomas (10%). These findings may help guide the management of sub-centimeter colon polyps found by OC or CTC.

  4. Colonoscope navigation system using colonoscope tracking method based on line registration

    NASA Astrophysics Data System (ADS)

    Oda, Masahiro; Kondo, Hiroaki; Kitasaka, Takayuki; Furukawa, Kazuhiro; Miyahara, Ryoji; Hirooka, Yoshiki; Goto, Hidemi; Navab, Nassir; Mori, Kensaku

    2014-03-01

    This paper presents a new colonoscope navigation system. CT colonography is utilized for colon diagnosis based on CT images. If polyps are found while CT colonography, colonoscopic polypectomy can be performed to remove them. While performing a colonoscopic examination, a physician controls colonoscope based on his/her experience. Inexperienced physicians may occur complications such as colon perforation while colonoscopic examinations. To reduce complications, a navigation system of colonoscope while performing the colonoscopic examinations is necessary. We propose a colonoscope navigation system. This system has a new colonoscope tracking method. This method obtains a colon centerline from a CT volume of a patient. A curved line (colonoscope line) representing the shape of colonoscope inserted to the colon is obtained by using electromagnetic sensors. A coordinate system registration process that employs the ICP algorithm is performed to register the CT and sensor coordinate systems. The colon centerline and colonoscope line are registered by using a line registration method. The position of the colonoscope tip in the colon is obtained from the line registration result. Our colonoscope navigation system displays virtual colonoscopic views generated from the CT volumes. A viewpoint of the virtual colonoscopic view is a point on the centerline that corresponds to the colonoscope tip. Experimental results using a colon phantom showed that the proposed colonoscope tracking method can track the colonoscope tip with small tracking errors.

  5. Endoscopic innovations to increase the adenoma detection rate during colonoscopy

    PubMed Central

    Dik, Vincent K; Moons, Leon MG; Siersema, Peter D

    2014-01-01

    Up to a quarter of polyps and adenomas are missed during colonoscopy due to poor visualization behind folds and the inner curves of flexures, and the presence of flat lesions that are difficult to detect. These numbers may however be conservative because they mainly come from back-to-back studies performed with standard colonoscopes, which are unable to visualize the entire mucosal surface. In the past several years, new endoscopic techniques have been introduced to improve the detection of polyps and adenomas. The introduction of high definition colonoscopes and visual image enhancement technologies have been suggested to lead to better recognition of flat and small lesions, but the absolute increase in diagnostic yield seems limited. Cap assisted colonoscopy and water-exchange colonoscopy are methods to facilitate cecal intubation and increase patients comfort, but show only a marginal or no benefit on polyp and adenoma detection. Retroflexion is routinely used in the rectum for the inspection of the dentate line, but withdrawal in retroflexion in the colon is in general not recommended due to the risk of perforation. In contrast, colonoscopy with the Third-Eye Retroscope® may result in considerable lower miss rates compared to standard colonoscopy, but this technique is not practical in case of polypectomy and is more time consuming. The recently introduced Full Spectrum Endoscopy™ colonoscopes maintains the technical capabilities of standard colonoscopes and provides a much wider view of 330 degrees compared to the 170 degrees with standard colonoscopes. Remarkable lower adenoma miss rates with this new technique were recently demonstrated in the first randomized study. Nonetheless, more studies are required to determine the exact additional diagnostic yield in clinical practice. Optimizing the efficacy of colorectal cancer screening and surveillance requires high definition colonoscopes with improved virtual chromoendoscopy technology that visualize the whole colon mucosa while maintaining optimal washing, suction and therapeutic capabilities, and keeping the procedural time as low and patient discomfort as optimal as possible. PMID:24605019

  6. Adaptive deformable model for colonic polyp segmentation and measurement on CT colonography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yao Jianhua; Summers, Ronald M.

    2007-05-15

    Polyp size is one important biomarker for the malignancy risk of a polyp. This paper presents an improved approach for colonic polyp segmentation and measurement on CT colonography images. The method is based on a combination of knowledge-guided intensity adjustment, fuzzy clustering, and adaptive deformable model. Since polyps on haustral folds are the most difficult to be segmented, we propose a dual-distance algorithm to first identify voxels on the folds, and then introduce a counter-force to control the model evolution. We derive linear and volumetric measurements from the segmentation. The experiment was conducted on 395 patients with 83 polyps, ofmore » which 43 polyps were on haustral folds. The results were validated against manual measurement from the optical colonoscopy and the CT colonography. The paired t-test showed no significant difference, and the R{sup 2} correlation was 0.61 for the linear measurement and 0.98 for the volumetric measurement. The mean Dice coefficient for volume overlap between automatic and manual segmentation was 0.752 (standard deviation 0.154)« less

  7. Faecal haemoglobin concentration influences risk prediction of interval cancers resulting from inadequate colonoscopy quality: analysis of the Taiwanese Nationwide Colorectal Cancer Screening Program

    PubMed Central

    Chiu, Sherry Yueh-Hsia; Chuang, Shu-Ling; Chen, Sam Li-Sheng; Yen, Amy Ming-Fang; Fann, Jean Ching-Yuan; Chang, Dun-Cheng; Lee, Yi-Chia; Wu, Ming-Shiang; Chou, Chu-Kuang; Hsu, Wen-Feng; Chiou, Shu-Ti; Chiu, Han-Mo

    2017-01-01

    Objectives Interval colorectal cancer (CRC) after colonoscopy may affect effectiveness and cost-effectiveness of screening programmes. We aimed to investigate whether and how faecal haemoglobin concentration (FHbC) of faecal immunochemical testing (FIT) affected the risk prediction of interval cancer (IC) caused by inadequate colonoscopy quality in a FIT-based population screening programme. Design From 2004 to 2009, 29 969 subjects underwent complete colonoscopy after positive FIT in the Taiwanese Nationwide CRC Screening Program. The IC rate was traced until the end of 2012. The incidence of IC was calculated in relation to patient characteristics, endoscopy-related factors (such adenoma detection rate (ADR)) and FHbC. Poisson regression analysis was performed to assess the potential risk factors for colonoscopy IC. Results One hundred and sixty-two ICs developed after an index colonoscopy and the estimated incidence was 1.14 per 1000 person-years of observation for the entire cohort. Increased risk of IC was most remarkable in the uptake of colonoscopy in settings with ADR lower than 15% (adjusted relative risk (aRR)=3.09, 95% CI 1.55 to 6.18) and then higher FHbC (μg Hb/g faeces) (100–149: aRR=2.55, 95% CI 1.52 to 4.29, ≥150: aRR=2.74, 95% CI 1.84 to 4.09) with adjustment for older age and colorectal neoplasm detected at baseline colonoscopy. Similar findings were observed for subjects with negative index colonoscopy. Conclusions Colonoscopy ICs arising from FIT-based population screening programmes were mainly influenced by inadequate colonoscopy quality and independently predicted by FHbC that is associated with a priori chance of advanced neoplasm. This finding is helpful for future modification of screening logistics based on FHbC. PMID:26515543

  8. "Appropriateness of colonoscopy according to EPAGE II in a low resource setting: a cross sectional study from Sri Lanka".

    PubMed

    Samarakoon, Yasara; Gunawardena, Nalika; Pathirana, Aloka; Hewage, Sumudu

    2018-05-29

    Due to finite resources, the clinical decision to subject a patient to colonoscopy needs to be based on the evidence, regardless of its availability, affordability and safety. This study assessed the appropriateness of colonoscopies conducted in selected study settings in Sri Lanka. In the absence of local guidelines, audit was based on European Panel on Appropriateness of Gastrointestinal Endoscopy II (EPAGE II) criteria. This cross-sectional study assessed consecutive patients who underwent colonoscopy between June to August 2015 at four main hospitals in Sri Lanka. Interviewer administered questionnaire and secondary data were collected by trained health staff. Indications were assessed according to EPAGE II criteria. Out of 325 patients, male female proportions were 57.2 and 42.8%. Mean (SD) age was 54.9 (12.1) years. Colonoscopies were appropriate in 61.2% (95% CI 55.8-66.3), uncertain in 28.6% (95% CI 23.9-33.7) and inappropriate in 10.2% (95% CI 7.3-13.9). Colonoscopy to evaluate abdominal pain has highest percentage of inappropriateness of 10.0%. However, 9.5% of these colonoscopies revealed Colo-Rectal Cancer (CRC), reflecting differences in the profile of local CRC patients. Colonoscopies with appropriate or uncertain indications are three times more likely to have a relevant finding than inappropriate indications (42.5% vs. 18.2%; OR 3.32, 95% CI 1.33-8.3; P = 0.008). Majority of colonoscopies are appropriate. However, it cannot be neglected that every one in ten patients undergo inappropriate colonoscopy. Proportion of inappropriateness was highest for the indication of chronic abdominal pain, of which, 9.5% of patients were diagnosed with CRC. This may reflect the different profile of local CRC patients in terms of symptom manifestation and other characteristics. In conclusion, the authors recommend formulation of national guidelines for colonoscopy indications based on current best evidence and local patient profile. Use of such prepared local guidelines will improve the efficient use of finite resources.

  9. Airways, vasculature, and interstitial tissue: anatomically informed computational modeling of human lungs for virtual clinical trials

    NASA Astrophysics Data System (ADS)

    Abadi, Ehsan; Sturgeon, Gregory M.; Agasthya, Greeshma; Harrawood, Brian; Hoeschen, Christoph; Kapadia, Anuj; Segars, W. P.; Samei, Ehsan

    2017-03-01

    This study aimed to model virtual human lung phantoms including both non-parenchymal and parenchymal structures. Initial branches of the non-parenchymal structures (airways, arteries, and veins) were segmented from anatomical data in each lobe separately. A volume-filling branching algorithm was utilized to grow the higher generations of the airways and vessels to the level of terminal branches. The diameters of the airways and vessels were estimated using established relationships between flow rates and diameters. The parenchyma was modeled based on secondary pulmonary lobule units. Polyhedral shapes with variable sizes were modeled, and the borders were assigned to interlobular septa. A heterogeneous background was added inside these units using a non-parametric texture synthesis algorithm which was informed by a high-resolution CT lung specimen dataset. A voxelized based CT simulator was developed to create synthetic helical CT images of the phantom with different pitch values. Results showed the progressive degradation in depiction of lung details with increased pitch. Overall, the enhanced lung models combined with the XCAT phantoms prove to provide a powerful toolset to perform virtual clinical trials in the context of thoracic imaging. Such trials, not practical using clinical datasets or simplistic phantoms, can quantitatively evaluate and optimize advanced imaging techniques towards patient-based care.

  10. Population-based respiratory 4D motion atlas construction and its application for VR simulations of liver punctures

    NASA Astrophysics Data System (ADS)

    Mastmeyer, Andre; Wilms, Matthias; Handels, Heinz

    2018-03-01

    Virtual reality (VR) training simulators of liver needle insertion in the hepatic area of breathing virtual patients often need 4D image data acquisitions as a prerequisite. Here, first a population-based breathing virtual patient 4D atlas is built and second the requirement of a dose-relevant or expensive acquisition of a 4D CT or MRI data set for a new patient can be mitigated by warping the mean atlas motion. The breakthrough contribution of this work is the construction and reuse of population-based, learned 4D motion models.

  11. Interactive CT-Video Registration for the Continuous Guidance of Bronchoscopy

    PubMed Central

    Merritt, Scott A.; Khare, Rahul; Bascom, Rebecca

    2014-01-01

    Bronchoscopy is a major step in lung cancer staging. To perform bronchoscopy, the physician uses a procedure plan, derived from a patient’s 3D computed-tomography (CT) chest scan, to navigate the bronchoscope through the lung airways. Unfortunately, physicians vary greatly in their ability to perform bronchoscopy. As a result, image-guided bronchoscopy systems, drawing upon the concept of CT-based virtual bronchoscopy (VB), have been proposed. These systems attempt to register the bronchoscope’s live position within the chest to a CT-based virtual chest space. Recent methods, which register the bronchoscopic video to CT-based endoluminal airway renderings, show promise but do not enable continuous real-time guidance. We present a CT-video registration method inspired by computer-vision innovations in the fields of image alignment and image-based rendering. In particular, motivated by the Lucas–Kanade algorithm, we propose an inverse-compositional framework built around a gradient-based optimization procedure. We next propose an implementation of the framework suitable for image-guided bronchoscopy. Laboratory tests, involving both single frames and continuous video sequences, demonstrate the robustness and accuracy of the method. Benchmark timing tests indicate that the method can run continuously at 300 frames/s, well beyond the real-time bronchoscopic video rate of 30 frames/s. This compares extremely favorably to the ≥1 s/frame speeds of other methods and indicates the method’s potential for real-time continuous registration. A human phantom study confirms the method’s efficacy for real-time guidance in a controlled setting, and, hence, points the way toward the first interactive CT-video registration approach for image-guided bronchoscopy. Along this line, we demonstrate the method’s efficacy in a complete guidance system by presenting a clinical study involving lung cancer patients. PMID:23508260

  12. A Web-based Multimedia Program Before Colonoscopy Increased Knowledge and Decreased Anxiety, Sedation Requirement, and Procedure Time.

    PubMed

    Parker, Siddhartha; Zipursky, Jonathan; Ma, Helen; Baumblatt, Geri-Lynn; Siegel, Corey A

    2018-07-01

    Assess the impact of a web-based multimedia patient engagement program on patient anxiety, perception and knowledge about the colonoscopy in addition to procedure outcomes. The success of patients coming for a colonoscopy for colorectal cancer screening is dependent in part on patients' understanding of the preparation and of the procedure. Patients were randomized to use either our institution's standard preprocedure colonoscopy packet or a web-based multimedia patient engagement program (Emmi Solutions) before their scheduled procedure. On the day of colonoscopy, all participants completed a survey including questions to assess knowledge and perception of colonoscopy, in addition to the State Trait Anxiety Inventory. We also collected procedure data including medication doses and procedure time. Patients in the experimental group correctly answered knowledge questions (82%) more often than the control group (74%) (P=0.0003). More than half (58%) of patients in the experimental group felt this intervention reduced their anxiety about the procedure, and the State Trait Anxiety Inventory anxiety score was lower in the experimental group (P=0.026). Patients who viewed the program required less midazolam (3.66 vs. 4.46 mg, P=0.0035) and total procedure time was shorter (24.8 vs. 29 min, P=0.024). A web-based multimedia patient engagement program watched before colonoscopy decreased patient anxiety, medication requirements, and procedure time while increasing knowledge. This intervention could help patients understand and feel more comfortable about colonoscopy leading to increased screening rates while increasing efficiency and decreasing recovery time.

  13. X-Ray microtomography for ant taxonomy: An exploration and case study with two new Terataner (Hymenoptera, Formicidae, Myrmicinae) species from Madagascar

    PubMed Central

    Fischer, Georg; Liu, Cong; Audisio, Tracy L.; Alpert, Gary D.; Fisher, Brian L.; Economo, Evan P.

    2017-01-01

    We explore the potential of x-ray micro computed tomography (μCT) for the field of ant taxonomy by using it to enhance the descriptions of two remarkable new species of the ant genus Terataner: T. balrog sp. n. and T. nymeria sp. n.. We provide an illustrated worker-based species identification key for all species found on Madagascar, as well as detailed taxonomic descriptions, which include diagnoses, discussions, measurements, natural history data, high-quality montage images and distribution maps for both new species. In addition to conventional morphological examination, we have used virtual reconstructions based on volumetric μCT scanning data for the species descriptions. We also include 3D PDFs, still images of virtual reconstructions, and 3D rotation videos for both holotype workers and one paratype queen. The complete μCT datasets have been made available online (Dryad, https://datadryad.org) and represent the first cybertypes in ants (and insects). We discuss the potential of μCT scanning and critically assess the usefulness of cybertypes for ant taxonomy. PMID:28328931

  14. Blurry-frame detection and shot segmentation in colonoscopy videos

    NASA Astrophysics Data System (ADS)

    Oh, JungHwan; Hwang, Sae; Tavanapong, Wallapak; de Groen, Piet C.; Wong, Johnny

    2003-12-01

    Colonoscopy is an important screening procedure for colorectal cancer. During this procedure, the endoscopist visually inspects the colon. Human inspection, however, is not without error. We hypothesize that colonoscopy videos may contain additional valuable information missed by the endoscopist. Video segmentation is the first necessary step for the content-based video analysis and retrieval to provide efficient access to the important images and video segments from a large colonoscopy video database. Based on the unique characteristics of colonoscopy videos, we introduce a new scheme to detect and remove blurry frames, and segment the videos into shots based on the contents. Our experimental results show that the average precision and recall of the proposed scheme are over 90% for the detection of non-blurry images. The proposed method of blurry frame detection and shot segmentation is extensible to the videos captured from other endoscopic procedures such as upper gastrointestinal endoscopy, enteroscopy, cystoscopy, and laparoscopy.

  15. Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm.

    PubMed

    Ahmadian, Alireza; Ay, Mohammad R; Bidgoli, Javad H; Sarkar, Saeed; Zaidi, Habib

    2008-10-01

    Oral contrast is usually administered in most X-ray computed tomography (CT) examinations of the abdomen and the pelvis as it allows more accurate identification of the bowel and facilitates the interpretation of abdominal and pelvic CT studies. However, the misclassification of contrast medium with high-density bone in CT-based attenuation correction (CTAC) is known to generate artifacts in the attenuation map (mumap), thus resulting in overcorrection for attenuation of positron emission tomography (PET) images. In this study, we developed an automated algorithm for segmentation and classification of regions containing oral contrast medium to correct for artifacts in CT-attenuation-corrected PET images using the segmented contrast correction (SCC) algorithm. The proposed algorithm consists of two steps: first, high CT number object segmentation using combined region- and boundary-based segmentation and second, object classification to bone and contrast agent using a knowledge-based nonlinear fuzzy classifier. Thereafter, the CT numbers of pixels belonging to the region classified as contrast medium are substituted with their equivalent effective bone CT numbers using the SCC algorithm. The generated CT images are then down-sampled followed by Gaussian smoothing to match the resolution of PET images. A piecewise calibration curve was then used to convert CT pixel values to linear attenuation coefficients at 511 keV. The visual assessment of segmented regions performed by an experienced radiologist confirmed the accuracy of the segmentation and classification algorithms for delineation of contrast-enhanced regions in clinical CT images. The quantitative analysis of generated mumaps of 21 clinical CT colonoscopy datasets showed an overestimation ranging between 24.4% and 37.3% in the 3D-classified regions depending on their volume and the concentration of contrast medium. Two PET/CT studies known to be problematic demonstrated the applicability of the technique in clinical setting. More importantly, correction of oral contrast artifacts improved the readability and interpretation of the PET scan and showed substantial decrease of the SUV (104.3%) after correction. An automated segmentation algorithm for classification of irregular shapes of regions containing contrast medium was developed for wider applicability of the SCC algorithm for correction of oral contrast artifacts during the CTAC procedure. The algorithm is being refined and further validated in clinical setting.

  16. Screening or Symptoms? How Do We Detect Colorectal Cancer in an Equal Access Health Care System?

    PubMed

    Hatch, Quinton M; Kniery, Kevin R; Johnson, Eric K; Flores, Shelly A; Moeil, David L; Thompson, John J; Maykel, Justin A; Steele, Scott R

    2016-02-01

    Detection of colorectal cancer ideally occurs at an early stage through proper screening. We sought to establish methods by which colorectal cancers are diagnosed within an equal access military health care population and evaluate the correlation between TNM stage at colorectal cancer diagnosis and diagnostic modality (i.e., symptomatic detection vs screen detection). A retrospective chart review of all newly diagnosed colorectal cancer patients from January 2007 to August 2014 was conducted at the authors' equal access military institution. We evaluated TNM stage relative to diagnosis by screen detection (fecal occult blood test, flexible sigmoidoscopy, CT colonography, colonoscopy) or symptomatic evaluation (diagnostic colonoscopy or surgery). Of 197 colorectal cancers diagnosed (59 % male; mean age 62 years), 50 (25 %) had stage I, 47 (24 %) had stage II, 70 (36 %) had stage III, and 30 (15 %) had stage IV disease. Twenty-five percent of colorectal cancers were detected via screen detection (3 % by fecal occult blood testing (FOBT), 0.5 % by screening CT colonography, 17 % by screening colonoscopy, and 5 % by surveillance colonoscopy). One hundred forty-eight (75 %) were diagnosed after onset of signs or symptoms. The preponderance of these was advanced-stage disease (stages III-IV), although >50 % of stage I-II disease also had signs or symptoms at diagnosis. The most common symptoms were rectal bleeding (45 %), abdominal pain (35 %), and change in stool caliber (27 %). The most common overall sign was anemia (60 %). Screening FOBT (odds ratio (OR) 8.7, 95 % confidence interval (CI) 1.0-78.3; P = 0.05) independently predicted early diagnosis with stage I-II disease. Patient gender and ethnicity were not associated with cancer stage at diagnosis. Despite equal access to colorectal cancer screening, diagnosis after development of symptomatic cancer remains more common. Fecal occult blood screen detection is associated with early stage at colorectal cancer diagnosis and is the focus for future initiatives.

  17. The Relationship of Endoscopic Proficiency to Educational Expense for Virtual Reality Simulator Training Amongst Surgical Trainees.

    PubMed

    Raque, Jessica; Goble, Adam; Jones, Veronica M; Waldman, Lindsey E; Sutton, Erica

    2015-07-01

    With the introduction of Fundamentals of Endoscopic Surgery, training methods in flexible endoscopy are being augmented with simulation-based curricula. The investment for virtual reality simulators warrants further research into its training advantage. Trainees were randomized into bedside or simulator training groups (BED vs SIM). SIM participated in a proficiency-based virtual reality curriculum. Trainees' endoscopic skills were rated using the Global Assessment of Gastrointestinal Endoscopic Skills (GAGES) in the patient care setting. The number of cases to reach 90 per cent of the maximum GAGES score and calculated costs of training were compared. Nineteen residents participated in the study. There was no difference in the average number of cases required to achieve 90 per cent of the maximum GAGES score for esophagogastroduodenoscopy, 13 (SIM) versus11 (BED) (P = 0.63), or colonoscopy 21 (SIM) versus 4 (BED) (P = 0.34). The average per case cost of training for esophagogastroduodenoscopy was $35.98 (SIM) versus $39.71 (BED) (P = 0.50), not including the depreciation costs associated with the simulator ($715.00 per resident over six years). Use of a simulator appeared to increase the cost of training without accelerating the learning curve or decreasing faculty time spent in instruction. The importance of simulation in endoscopy training will be predicated on more cost-effective simulators.

  18. Comparison of virtual monoenergetic and polyenergetic images reconstructed from dual-layer detector CT angiography of the head and neck.

    PubMed

    Neuhaus, Victor; Große Hokamp, Nils; Abdullayev, Nuran; Maus, Volker; Kabbasch, Christoph; Mpotsaris, Anastasios; Maintz, David; Borggrefe, Jan

    2018-03-01

    To compare the image quality of virtual monoenergetic images and polyenergetic images reconstructed from dual-layer detector CT angiography (DLCTA). Thirty patients who underwent DLCTA of the head and neck were retrospectively identified and polyenergetic as well as virtual monoenergetic images (40 to 120 keV) were reconstructed. Signals (± SD) of the cervical and cerebral vessels as well as lateral pterygoid muscle and the air surrounding the head were measured to calculate the CNR and SNR. In addition, subjective image quality was assessed using a 5-point Likert scale. Student's t-test and Wilcoxon test were used to determine statistical significance. Compared to polyenergetic images, although noise increased with lower keV, CNR (p < 0.02) and SNR (p > 0.05) of the cervical, petrous and intracranial vessels were improved in virtual monoenergetic images at 40 keV and virtual monoenergetic images at 45 keV were also rated superior regarding vascular contrast, assessment of arteries close to the skull base and small arterial branches (p < 0.0001 each). Compared to polyenergetic images, virtual monoenergetic images reconstructed from DLCTA at low keV ranging from 40 to 45 keV improve the objective and subjective image quality of extra- and intracranial vessels and facilitate assessment of vessels close to the skull base and of small arterial branches. • Virtual monoenergetic images greatly improve attenuation, while noise only slightly increases. • Virtual monoenergetic images show superior contrast-to-noise ratios compared to polyenergetic images. • Virtual monoenergetic images significantly improve image quality at low keV.

  19. A Longitudinal Study of Adenoma Detection Rate in Gastroenterology Fellowship Training.

    PubMed

    Gianotti, Robert J; Oza, Sveta Shah; Tapper, Elliot B; Kothari, Darshan; Sheth, Sunil G

    2016-10-01

    Current guidelines suggest that a gastroenterology fellow in training needs to perform 140 colonoscopies to achieve competency. Data are limited regarding adenoma detection rate (ADR) in fellowship. To assess how fellow ADR correlates with number of colonoscopies performed. We performed a retrospective study examining consecutive colonoscopies performed by gastroenterology fellows. Fellow ADR before and after the 140 procedure benchmark was compared to colonoscopies performed by attending only with whom these fellows trained. A threshold for ideal procedure count was performed using ROC analysis. We analyzed 2021 average-risk colonoscopies performed by 10 gastroenterology fellows under the supervision of an attending physician. When fellows had performed <140 colonoscopies, the ADR was 27 % compared with an ADR of 36 % when fellows had performed >140 colonoscopies under attending supervision (p = 0.02). The ADR of fellows who had performed >140 colonoscopies under attending supervision was greater than that of attending-only colonoscopies (36 vs. 25 %, p < 0.0001). A threshold of >325 (male patients) and 539 (female patients) colonoscopies was determined to be ideal for achieving adequate ADR based on ROC analysis. Our data suggest that ADR increases after fellows perform >140 colonoscopies under attending supervision, and thereafter surpasses the ADR of attending-only colonoscopies. Some of the differences may be driven by detection of small adenomas. The findings of this study suggest that a higher threshold for number of colonoscopies performed under attending supervision may be needed to achieve adequate ADR during fellowship prior to independent practice.

  20. Unsedation colonoscopy can be not that painful: Evaluation of the effect of "Lamaze method of colonoscopy".

    PubMed

    Yu, Shao-Ping; Lin, Xiao-Dong; Wu, Guang-Yao; Li, Song-Hu; Wen, Zong-Quan; Cen, Xiao-Hong; Huang, Xian-Guang; Huang, Mei-Ting

    2015-10-25

    To evaluate the pain relieving effect of intervention with "Lamaze method of colonoscopy" in the process of colonoscopy. Five hundred and eighty-five patients underwent colonoscopy were randomly divided into three groups, Lamaze group, anesthetic group and control group. Two hundred and twenty-four patients of Lamaze group, the "Lamaze method of colonoscopy" were practiced in the process of colonoscopy. The Lamaze method of colonoscopy is modified from the Lamaze method of childbirth, which helped patients to relieve pain through effective breathing control. One hundred and seventy-eight patients in anesthetic group accepted sedation colonoscopy. For 183 patients in control group, colonoscopy was performed without any intervention. The satisfactory of colon cleaning, intestinal lesions, intubation time, success ratio, pain grading and complications were recorded. All data were statistically analyzed. There were no significant differences at base line of the three groups (P > 0.05). Anesthetic group shows advantage in intubation time than the other two groups (P < 0.05). Lamaze group shows no advantage in intubation time than that in control group (P > 0.05). The anesthetic group showed an apparent advantage in relieving pain (P < 0.01). Therefore, the "Lamaze method of colonoscopy" performed in colonoscopy could relieve pain effectively comparing with control group (P < 0.05). The patients in anesthetic group had the highest incidence of complications (P < 0.05). The performance of the "Lamaze method of colonoscopy" in the process of colonoscopy could relieve patients' pain, minimize the incidence of complications, and is worthy promotion in clinical practice.

  1. The utility of Google Trends data to examine interest in cancer screening

    PubMed Central

    Schootman, M; Toor, A; Cavazos-Rehg, P; Jeffe, D B; McQueen, A; Eberth, J; Davidson, N O

    2015-01-01

    Objectives We examined the utility of January 2004 to April 2014 Google Trends data from information searches for cancer screenings and preparations as a complement to population screening data, which are traditionally estimated through costly population-level surveys. Setting State-level data across the USA. Participants Persons who searched for terms related to cancer screening using Google, and persons who participated in the Behavioral Risk Factor Surveillance System (BRFSS). Primary and secondary outcome measures (1) State-level Google Trends data, providing relative search volume (RSV) data scaled to the highest search proportion per week (RSV100) for search terms over time since 2004 and across different geographical locations. (2) RSV of new screening tests, free/low-cost screening for breast and colorectal cancer, and new preparations for colonoscopy (Prepopik). (3) State-level breast, cervical, colorectal and prostate cancer screening rates. Results Correlations between Google Trends and BRFSS data ranged from 0.55 for ever having had a colonoscopy to 0.14 for having a Pap smear within the past 3 years. Free/low-cost mammography and colonoscopy showed higher RSV during their respective cancer awareness months. RSV for Miralax remained stable, while interest in Prepopik increased over time. RSV for lung cancer screening, virtual colonoscopy and three-dimensional mammography was low. Conclusions Google Trends data provides enormous scientific possibilities, but are not a suitable substitute for, but may complement, traditional data collection and analysis about cancer screening and related interests. PMID:26056120

  2. Demand for Colonoscopy in Colorectal Cancer Screening Using a Quantitative Fecal Immunochemical Test and Age/Sex-Specific Thresholds for Test Positivity.

    PubMed

    Chen, Sam Li-Sheng; Hsu, Chen-Yang; Yen, Amy Ming-Fang; Young, Graeme P; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Lee, Yi-Chia; Chiu, Han-Mo; Chiou, Shu-Ti; Chen, Hsiu-Hsi

    2018-06-01

    Background: Despite age and sex differences in fecal hemoglobin (f-Hb) concentrations, most fecal immunochemical test (FIT) screening programs use population-average cut-points for test positivity. The impact of age/sex-specific threshold on FIT accuracy and colonoscopy demand for colorectal cancer screening are unknown. Methods: Using data from 723,113 participants enrolled in a Taiwanese population-based colorectal cancer screening with single FIT between 2004 and 2009, sensitivity and specificity were estimated for various f-Hb thresholds for test positivity. This included estimates based on a "universal" threshold, receiver-operating-characteristic curve-derived threshold, targeted sensitivity, targeted false-positive rate, and a colonoscopy-capacity-adjusted method integrating colonoscopy workload with and without age/sex adjustments. Results: Optimal age/sex-specific thresholds were found to be equal to or lower than the universal 20 μg Hb/g threshold. For older males, a higher threshold (24 μg Hb/g) was identified using a 5% false-positive rate. Importantly, a nonlinear relationship was observed between sensitivity and colonoscopy workload with workload rising disproportionately to sensitivity at 16 μg Hb/g. At this "colonoscopy-capacity-adjusted" threshold, the test positivity (colonoscopy workload) was 4.67% and sensitivity was 79.5%, compared with a lower 4.0% workload and a lower 78.7% sensitivity using 20 μg Hb/g. When constrained on capacity, age/sex-adjusted estimates were generally lower. However, optimizing age/-sex-adjusted thresholds increased colonoscopy demand across models by 17% or greater compared with a universal threshold. Conclusions: Age/sex-specific thresholds improve FIT accuracy with modest increases in colonoscopy demand. Impact: Colonoscopy-capacity-adjusted and age/sex-specific f-Hb thresholds may be useful in optimizing individual screening programs based on detection accuracy, population characteristics, and clinical capacity. Cancer Epidemiol Biomarkers Prev; 27(6); 704-9. ©2018 AACR . ©2018 American Association for Cancer Research.

  3. Early prosthetic aortic valve infection identified with the use of positron emission tomography in a patient with lead endocarditis.

    PubMed

    Amraoui, Sana; Tlili, Ghoufrane; Sohal, Manav; Bordenave, Laurence; Bordachar, Pierre

    2016-12-01

    18-Fluorodeoxyglucose positron emission tomography/computerized tomography (FDG PET/CT) scanning has recently been proposed as a diagnostic tool for lead endocarditis (LE). FDG PET/CT might be also useful to localize associated septic emboli in patients with LE. We report an interesting case of a LE patient with a prosthetic aortic valve in whom a trans-esophageal echocardiogram did not show associated aortic endocarditis. FDG PET/CT revealed prosthetic aortic valve infection. A second TEE performed 2 weeks after identified aortic vegetation. A longer duration of antimicrobial therapy with serial follow-up echocardiography was initiated. There was also increased uptake in the sigmoid colon, corresponding to focal polyps resected during a colonoscopy. FDG PET/CT scanning seems to be highly sensitive for prosthetic aortic valve endocarditis diagnosis. This promising diagnostic tool may be beneficial in LE patients, by identifying septic emboli and potential sites of pathogen entry.

  4. CT colonography of colorectal polyps: a metaanalysis.

    PubMed

    Sosna, Jacob; Morrin, Martina M; Kruskal, Jonathan B; Lavin, Philip T; Rosen, Max P; Raptopoulos, Vassilios

    2003-12-01

    For proper evaluation of the accuracy of CT colonography, prospective multiinstitutional trials would be ideal. Until these trials are available, data can be collectively analyzed. The purpose of this study is to use metaanalysis to assess the reported accuracy of CT colonography compared with conventional colonoscopy for detecting colorectal polyps. Articles comparing CT colonography and conventional colonoscopy were identified, and a standardized form was used to extract relevant study data. Fisher's exact test and the Mantel-Haenszel test were used for pooling of data. A 95% confidence interval (CI) was selected to determine sensitivity and specificity, and the Kruskal-Wallis exact test was used to identify trends relating to polyp size. Meta-analysis methods were used to test strength of results. Comparisons were made for the percentage of polyps detected grouped by size (> or = 10 mm, 6-9 mm, < or = 5 mm) and the percentage of patients identified who had polyps of the same size. Fourteen studies fulfilled all the study inclusion criteria and gave a total of 1,324 patients and 1,411 polyps. The pooled per-patient sensitivity for polyps 10 mm or larger was (sensitivity [95% CI]) 0.88 (0.84-0.93), for polyps 6-9 mm it was 0.84 (0.80-0.89), and for polyps 5 mm or smaller it was 0.65 (0.57-0.73). The pooled per-polyp sensitivity for polyps 10 mm or larger was 0.81 (0.76-0.85), for polyps 6-9 mm it was 0.62 (0.58-0.67), and for polyps 5 mm or smaller it was 0.43 (0.39-0.47). Sensitivity for detection of polyps increased as the polyp size increased (p < 0.00005). The pooled overall specificity for detection of polyps larger than 10 mm was 0.95 (0.94-0.97). The specificity and sensitivity of CT colonography are high for polyps larger than 10 mm.

  5. Immersive virtual reality for visualization of abdominal CT

    NASA Astrophysics Data System (ADS)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A.; Bodenheimer, Robert E.

    2013-03-01

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  6. Immersive Virtual Reality for Visualization of Abdominal CT.

    PubMed

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A; Bodenheimer, Robert E

    2013-03-28

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two-dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  7. Intention to undergo colonoscopy screening among relatives of colorectal cancer cases: a theory-based model.

    PubMed

    Boonyasiriwat, Watcharaporn; Hung, Man; Hon, Shirley D; Tang, Philip; Pappas, Lisa M; Burt, Randall W; Schwartz, Marc D; Stroup, Antoinette M; Kinney, Anita Y

    2014-06-01

    It is recommended that persons having familial risk of colorectal cancer begin regular colonoscopy screening at an earlier age than those in the general population. However, many individuals at increased risk do not adhere to these screening recommendations. The goal of this study was to examine cognitive, affective, social, and behavioral motivators of colonoscopy intention among individuals at increased risk of familial colorectal cancer. Relatives of colorectal cancer cases (N = 481) eligible for colonoscopy screening completed a survey assessing constructs from several theoretical frameworks including fear appeal theories. Structural equation modeling indicated that perceived colorectal cancer risk, past colonoscopy, fear of colorectal cancer, support from family and friends, and health-care provider recommendation were determinants of colonoscopy intention. Future interventions to promote colonoscopy in this increased risk population should target the factors we identified as motivators. (ClinicalTrials.gov number NCT01274143).

  8. Correlation Between Findings of Multislice Helical Computed Tomography (CT), Endoscopic Examinations, Endovascular Procedures, and Surgery in Patients with Symptoms of Acute Gastrointestinal Bleeding

    PubMed Central

    Konecki, Dariusz; Pacho, Ryszard; Rowiński, Olgierd

    2017-01-01

    Summary Background Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. Material/Methods The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. Results The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. Conclusions CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding. PMID:29662594

  9. Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT.

    PubMed

    Leng, Shuai; Yu, Lifeng; Fletcher, Joel G; McCollough, Cynthia H

    2015-08-01

    To determine the iodine contrast-to-noise ratio (CNR) for abdominal computed tomography (CT) when using energy domain noise reduction and virtual monoenergetic dual-energy (DE) CT images and to compare the CNR to that attained with single-energy CT at 80, 100, 120, and 140 kV. This HIPAA-compliant study was approved by the institutional review board with waiver of informed consent. A syringe filled with diluted iodine contrast material was placed into 30-, 35-, and 45-cm-wide water phantoms and scanned with a dual-source CT scanner in both DE and single-energy modes with matched scanner output. Virtual monoenergetic images were generated, with energies ranging from 40 to 110 keV in 10-keV steps. A previously developed energy domain noise reduction algorithm was applied to reduce image noise by exploiting information redundancies in the energy domain. Image noise and iodine CNR were calculated. To show the potential clinical benefit of this technique, it was retrospectively applied to a clinical DE CT study of the liver in a 59-year-old male patient by using conventional and iterative reconstruction techniques. Image noise and CNR were compared for virtual monoenergetic images with and without energy domain noise reduction at each virtual monoenergetic energy (in kiloelectron volts) and phantom size by using a paired t test. CNR of virtual monoenergetic images was also compared with that of single-energy images acquired with 80, 100, 120, and 140 kV. Noise reduction of up to 59% (28.7 of 65.7) was achieved for DE virtual monoenergetic images by using an energy domain noise reduction technique. For the commercial virtual monoenergetic images, the maximum iodine CNR was achieved at 70 keV and was 18.6, 16.6, and 10.8 for the 30-, 35-, and 45-cm phantoms. After energy domain noise reduction, maximum iodine CNR was achieved at 40 keV and increased to 30.6, 25.4, and 16.5. These CNRs represented improvement of up to 64% (12.0 of 18.6) with the energy domain noise reduction technique. For single-energy CT at the optimal tube potential, iodine CNR was 29.1 (80 kV), 21.2 (80 kV), and 11.5 (100 kV). For patient images, 39% (24 of 61) noise reduction and 67% (0.74 of 1.10) CNR improvement were observed with the energy domain noise reduction technique when compared with standard filtered back-projection images. Iodine CNR for adult abdominal CT may be maximized with energy domain noise reduction and virtual monoenergetic DE CT. (©) RSNA, 2015.

  10. VirSSPA- a virtual reality tool for surgical planning workflow.

    PubMed

    Suárez, C; Acha, B; Serrano, C; Parra, C; Gómez, T

    2009-03-01

    A virtual reality tool, called VirSSPA, was developed to optimize the planning of surgical processes. Segmentation algorithms for Computed Tomography (CT) images: a region growing procedure was used for soft tissues and a thresholding algorithm was implemented to segment bones. The algorithms operate semiautomati- cally since they only need seed selection with the mouse on each tissue segmented by the user. The novelty of the paper is the adaptation of an enhancement method based on histogram thresholding applied to CT images for surgical planning, which simplifies subsequent segmentation. A substantial improvement of the virtual reality tool VirSSPA was obtained with these algorithms. VirSSPA was used to optimize surgical planning, to decrease the time spent on surgical planning and to improve operative results. The success rate increases due to surgeons being able to see the exact extent of the patient's ailment. This tool can decrease operating room time, thus resulting in reduced costs. Virtual simulation was effective for optimizing surgical planning, which could, consequently, result in improved outcomes with reduced costs.

  11. Risk of Metachronous High-Risk Adenomas and Large Serrated Polyps in Individuals With Serrated Polyps on Index Colonoscopy: Data From the New Hampshire Colonoscopy Registry.

    PubMed

    Anderson, Joseph C; Butterly, Lynn F; Robinson, Christina M; Weiss, Julia E; Amos, Christopher; Srivastava, Amitabh

    2018-01-01

    Surveillance guidelines for serrated polyps (SPs) are based on limited data on longitudinal outcomes of patients. We used the New Hampshire Colonoscopy Registry to evaluate risk of clinically important metachronous lesions associated with SPs detected during index colonoscopies. We collected data from a population-based colonoscopy registry that has been collecting and analyzing data on colonoscopies across the state of New Hampshire since 2004, including rates of adenoma and SP detection. Patients completed a questionnaire to determine demographic characteristics, health history, and risk factors for colorectal cancer, and were followed from index colonoscopy through all subsequent surveillance colonoscopies. Our analyses included 5433 participants (median age, 61 years; 49.7% male) with 2 colonoscopies (median time to surveillance, 4.9 years). We used multivariable logistic regression models to assess effects of index SPs (n = 1016), high-risk adenomas (HRA, n = 817), low-risk adenomas (n = 1418), and no adenomas (n = 3198) on subsequent HRA or large SPs (>1 cm) on surveillance colonoscopy (metachronous lesions). Synchronous SPs, within each index risk group, were assessed for size and by histology. SPs comprise hyperplastic polyps, sessile serrated adenomas/polyps (SSA/Ps), and traditional serrated adenomas. In this study, SSA/Ps and traditional serrated adenomas are referred to collectively as STSAs. HRA and synchronous large SP (odds ratio [OR], 5.61; 95% confidence interval [CI], 1.72-18.28), HRA with synchronous STSA (OR, 16.04; 95% CI, 6.95-37.00), and HRA alone (OR, 3.86; 95% CI, 2.77-5.39) at index colonoscopy significantly increased the risk of metachronous HRA compared to the reference group (no index adenomas or SPs). Large index SPs alone (OR, 14.34; 95% CI, 5.03-40.86) or index STSA alone (OR, 9.70; 95% CI, 3.63-25.92) significantly increased the risk of a large metachronous SP. In an analysis of data from a population-based colonoscopy registry, we found index large SP or index STSA with no index HRA increased risk of metachronous large SPs but not metachronous HRA. HRA and synchronous SPs at index colonoscopy significantly increased risk of metachronous HRA. Individuals with HRA and synchronous large SP or any STSA could therefore benefit from close surveillance. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  12. Scalable, High-performance 3D Imaging Software Platform: System Architecture and Application to Virtual Colonoscopy

    PubMed Central

    Yoshida, Hiroyuki; Wu, Yin; Cai, Wenli; Brett, Bevin

    2013-01-01

    One of the key challenges in three-dimensional (3D) medical imaging is to enable the fast turn-around time, which is often required for interactive or real-time response. This inevitably requires not only high computational power but also high memory bandwidth due to the massive amount of data that need to be processed. In this work, we have developed a software platform that is designed to support high-performance 3D medical image processing for a wide range of applications using increasingly available and affordable commodity computing systems: multi-core, clusters, and cloud computing systems. To achieve scalable, high-performance computing, our platform (1) employs size-adaptive, distributable block volumes as a core data structure for efficient parallelization of a wide range of 3D image processing algorithms; (2) supports task scheduling for efficient load distribution and balancing; and (3) consists of a layered parallel software libraries that allow a wide range of medical applications to share the same functionalities. We evaluated the performance of our platform by applying it to an electronic cleansing system in virtual colonoscopy, with initial experimental results showing a 10 times performance improvement on an 8-core workstation over the original sequential implementation of the system. PMID:23366803

  13. WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, W; Rao, A; Wendt, R

    Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded asmore » it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration framework that is clinically valuable and requires no specialized equipment.« less

  14. Analysis of patient CT dose data using virtualdose

    NASA Astrophysics Data System (ADS)

    Bennett, Richard

    X-ray computer tomography has many benefits to medical and research applications. Recently, over the last decade CT has had a large increase in usage in hospitals and medical diagnosis. In pediatric care, from 2000 to 2006, abdominal CT scans increased by 49 % and chest CT by 425 % in the emergency room (Broder 2007). Enormous amounts of effort have been performed across multiple academic and government groups to determine an accurate measure of organ dose to patients who undergo a CT scan due to the inherent risks with ionizing radiation. Considering these intrinsic risks, CT dose estimating software becomes a necessary tool that health care providers and radiologist must use to determine many metrics to base the risks versus rewards of having an x-ray CT scan. This thesis models the resultant organ dose as body mass increases for patients with all other related scan parameters fixed. In addition to this,this thesis compares a modern dose estimating software, VirtualDose CT to two other programs, CT-Expo and ImPACT CT. The comparison shows how the software's theoretical basis and the phantom they use to represent the human body affect the range of results in organ dose. CT-Expo and ImPACT CT dose estimating software uses a different model for anatomical representation of the organs in the human body and the results show how that approach dramatically changes the outcome. The results categorizes four datasets as compared to the three software types where the appropriate phantom was available. Modeling was done to simulate chest abdominal pelvis scans and whole body scans. Organ dose difference versus body mass index shows as body mass index (BMI) ranges from 23.5 kg/m 2 to 45 kg/m2 the amount of organ dose also trends a percent change from -4.58 to -176.19 %. Comparing organ dose difference with increasing x-ray tube potential from 120 kVp to 140 kVp the percent change in organ dose increases from 55 % to 65 % across all phantoms. In comparing VirtualDose to CT-Expo for organ dose difference versus age, male phantoms show percent difference of -19 % to 25 % for various organs minus bone surface and breast tissues results. Finally, for organ dose difference across all software for average adult phantom the results range from -45 % to 6 % in the comparison of ImPACT CT to VirtualDose and -27 % to 66 % for the comparison of CT-Expo to VirtualDose. In the comparison for increased BMI (done only in VirtualDose), results show that with all other parameters fixed, the organ dose goes down as BMI increases, which is due to the increase in adipose tissue and bulk of the patient model. The range of results when comparing all the three softwares have a wide range, in some cases greater than 150 %, it is evident that using a different anatomical basis for the human phantom and the theoretical basis for the dose estimation will cause fluctuation in the results. Therefore, choosing the software with the most accurate human phantom will provide a closer range to the true dose to the organ.

  15. Virtual 3D planning of tracheostomy placement and clinical applicability of 3D cannula design: a three-step study.

    PubMed

    de Kleijn, Bertram J; Kraeima, Joep; Wachters, Jasper E; van der Laan, Bernard F A M; Wedman, Jan; Witjes, M J H; Halmos, Gyorgy B

    2018-02-01

    We aimed to investigate the potential of 3D virtual planning of tracheostomy tube placement and 3D cannula design to prevent tracheostomy complications due to inadequate cannula position. 3D models of commercially available cannula were positioned in 3D models of the airway. In study (1), a cohort that underwent tracheostomy between 2013 and 2015 was selected (n = 26). The cannula was virtually placed in the airway in the pre-operative CT scan and its position was compared to the cannula position on post-operative CT scans. In study (2), a cohort with neuromuscular disease (n = 14) was analyzed. Virtual cannula placing was performed in CT scans and tested if problems could be anticipated. Finally (3), for a patient with Duchenne muscular dystrophy and complications of conventional tracheostomy cannula, a patient-specific cannula was 3D designed, fabricated, and placed. (1) The 3D planned and post-operative tracheostomy position differed significantly. (2) Three groups of patients were identified: (A) normal anatomy; (B) abnormal anatomy, commercially available cannula fits; and (C) abnormal anatomy, custom-made cannula, may be necessary. (3) The position of the custom-designed cannula was optimal and the trachea healed. Virtual planning of the tracheostomy did not correlate with actual cannula position. Identifying patients with abnormal airway anatomy in whom commercially available cannula cannot be optimally positioned is advantageous. Patient-specific cannula design based on 3D virtualization of the airway was beneficial in a patient with abnormal airway anatomy.

  16. Quantitative assessment of anatomical change using a virtual proton depth radiograph for adaptive head and neck proton therapy.

    PubMed

    Wang, Peng; Yin, Lingshu; Zhang, Yawei; Kirk, Maura; Song, Gang; Ahn, Peter H; Lin, Alexander; Gee, James; Dolney, Derek; Solberg, Timothy D; Maughan, Richard; McDonough, James; Teo, Boon-Keng Kevin

    2016-03-08

    The aim of this work is to demonstrate the feasibility of using water-equivalent thickness (WET) and virtual proton depth radiographs (PDRs) of intensity corrected cone-beam computed tomography (CBCT) to detect anatomical change and patient setup error to trigger adaptive head and neck proton therapy. The planning CT (pCT) and linear accelerator (linac) equipped CBCTs acquired weekly during treatment of a head and neck patient were used in this study. Deformable image registration (DIR) was used to register each CBCT with the pCT and map Hounsfield units (HUs) from the planning CT (pCT) onto the daily CBCT. The deformed pCT is referred as the corrected CBCT (cCBCT). Two dimensional virtual lateral PDRs were generated using a ray-tracing technique to project the cumulative WET from a virtual source through the cCBCT and the pCT onto a virtual plane. The PDRs were used to identify anatomic regions with large variations in the proton range between the cCBCT and pCT using a threshold of 3 mm relative difference of WET and 3 mm search radius criteria. The relationship between PDR differences and dose distribution is established. Due to weight change and tumor response during treatment, large variations in WETs were observed in the relative PDRs which corresponded spatially with an increase in the number of failing points within the GTV, especially in the pharynx area. Failing points were also evident near the posterior neck due to setup variations. Differences in PDRs correlated spatially to differences in the distal dose distribution in the beam's eye view. Virtual PDRs generated from volumetric data, such as pCTs or CBCTs, are potentially a useful quantitative tool in proton therapy. PDRs and WET analysis may be used to detect anatomical change from baseline during treatment and trigger further analysis in adaptive proton therapy.

  17. Visuomotor adaptation in head-mounted virtual reality versus conventional training

    PubMed Central

    Anglin, J. M.; Sugiyama, T.; Liew, S.-L.

    2017-01-01

    Immersive, head-mounted virtual reality (HMD-VR) provides a unique opportunity to understand how changes in sensory environments affect motor learning. However, potential differences in mechanisms of motor learning and adaptation in HMD-VR versus a conventional training (CT) environment have not been extensively explored. Here, we investigated whether adaptation on a visuomotor rotation task in HMD-VR yields similar adaptation effects in CT and whether these effects are achieved through similar mechanisms. Specifically, recent work has shown that visuomotor adaptation may occur via both an implicit, error-based internal model and a more cognitive, explicit strategic component. We sought to measure both overall adaptation and balance between implicit and explicit mechanisms in HMD-VR versus CT. Twenty-four healthy individuals were placed in either HMD-VR or CT and trained on an identical visuomotor adaptation task that measured both implicit and explicit components. Our results showed that the overall timecourse of adaption was similar in both HMD-VR and CT. However, HMD-VR participants utilized a greater cognitive strategy than CT, while CT participants engaged in greater implicit learning. These results suggest that while both conditions produce similar results in overall adaptation, the mechanisms by which visuomotor adaption occurs in HMD-VR appear to be more reliant on cognitive strategies. PMID:28374808

  18. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    NASA Astrophysics Data System (ADS)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  19. Opportunistic screening of hospital staff using primary colonoscopy: participation, discomfort and willingness to repeat the procedure.

    PubMed

    Khalid-de Bakker, C A; Jonkers, D M; Hameeteman, W; de Ridder, R J; Masclee, A A; Stockbrügger, R W

    2011-01-01

    Participation in and tolerability of primary colonoscopy screening are presumed to be relatively low. The present study aimed to test its feasibility in a well-informed population of hospital staff using an intensive information campaign, and to identify factors associated with screening colonoscopy rated as uncomfortable. Data were collected using standardized forms. Out of 1,090 invited employees (50-65 years), 447 (41.0%) participated. Bowel preparation and colonoscopy were rated as 'somewhat to very uncomfortable' by 79.5 and 21.9%, respectively. 96.3% of participants were willing to repeat colonoscopy in the future. Participants rating colonoscopy as uncomfortable were more likely unwilling to repeat the procedure (OR 8.026, CI 2.667-24.154). Multivariate analysis (age- and gender-adjusted) showed an association of colonoscopy rated as uncomfortable with: abdominal pain during colonoscopy (OR 3.185, CI 1.642-6.178), other pain (OR 2.428, CI 1.335-4.416), flatulence (OR 2.175, CI 1.219-3.881), embarrassment (OR 2.843, CI 1.350-5.989), abdominal pain after colonoscopy (OR 1.976, CI 1.041-3.751), and a prolonged procedure time (OR 1.000, CI 1.000-1.001). Acceptance of primary colonoscopy screening for colorectal neoplasia was high, although participants with symptoms during and after colonoscopy were more likely to rate colonoscopy as uncomfortable. This type of opportunistic screening procedure is suitable for the introduction of screening programs and may be useful in areas that have no access to population-based screening. Copyright © 2011 S. Karger AG, Basel.

  20. Technical Note: Relation between dual-energy subtraction of CT images for electron density calibration and virtual monochromatic imaging.

    PubMed

    Saito, Masatoshi

    2015-07-01

    For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the author previously proposed a simple conversion of the energy-subtracted computed tomography (CT) number to an electron density (ΔHU-ρe conversion), which provides a single linear relationship between ΔHU and ρe over a wide ρe range. The purpose of the present study was to reveal the relation between the ΔHU image for ρe calibration and a virtually monochromatic CT image by performing numerical analyses based on the basis material decomposition in dual-energy CT. The author determined the weighting factor, α0, of the ΔHU-ρe conversion through numerical analyses of the International Commission on Radiation Units and Measurements Report-46 human body tissues using their attenuation coefficients and given ρe values. Another weighting factor, α(E), for synthesizing a virtual monochromatic CT image from high- and low-kV CT images, was also calculated in the energy range of 0.03 < E < 5 MeV, assuming that cortical bone and water were the basis materials. The mass attenuation coefficients for these materials were obtained using the xcom photon cross sections database. The effective x-ray energies used to calculate the attenuation were chosen to imitate a dual-source CT scanner operated at 80-140 and 100-140 kV/Sn. The determined α0 values were 0.455 for 80-140 kV/Sn and 0.743 for 100-140 kV/Sn. These values coincided almost perfectly with the respective maximal points of the calculated α(E) curves located at approximately 1 MeV, in which the photon-matter interaction in human body tissues is exclusively the incoherent (Compton) scattering. The ΔHU image could be regarded substantially as a CT image acquired with monoenergetic 1-MeV photons, which provides a linear relationship between CT numbers and electron densities.

  1. Serious events in older Ontario residents receiving bowel preparations for outpatient colonoscopy with various comorbidity profiles: A descriptive, population-based study

    PubMed Central

    Ho, Joanne M; Gruneir, Andrea; Fischer, Hadas D; Fu, Longdi; Lipscombe, Lorraine L; Bell, Chaim M; Cavalcanti, Rodrigo B; Anderson, Geoffrey M; Rochon, Paula A

    2012-01-01

    BACKGROUND: Polyethylene glycol-based bowel preparations (PEGBPs) and sodium picosulfate (NaPS) are commonly used for bowel cleansing before colonoscopy. Little is known about adverse events associated with these preparations, particularly in older patients or patients with medical comorbidities. OBJECTIVE: To characterize the incidence of serious events following outpatient colonoscopy in patients using PEGBPs or NaPS. METHODS: The present population-based retrospective cohort study examined data from Ontario health care databases between April 1, 2005 and December 31, 2007, including patients ≥66 years of age who received either PEGBP or NaPS for an outpatient colonoscopy. Patients with cardiac or renal disease, long-term care residents or patients receiving concurrent diuretic therapy were identified as high risk for adverse events. The primary outcome was a serious event (SE) defined as a composite of nonelective hospitalization, emergency department visit or death within seven days of the colonoscopy. RESULTS: Of the 50,660 outpatients ≥66 years of age who underwent a colonoscopy, SEs were observed in 675 (2.4%) and 543 (2.4%) patients in the PEGBP and NaPS groups, respectively. Among high-risk patients (n=30,168), SEs occurred in 481 (2.8%) and 367 (2.8%) of patients receiving PEGBP and NaPS, respectively. CONCLUSIONS: The SE rate within seven days of outpatient colonoscopy was 24 per 1000 procedures, and among high-risk patients was 28 per 1000 procedures. The rates were similar for PEGBP and NaPS. Clinicians should be aware of the risks associated with colonoscopy in older patients with comorbidities. PMID:22803018

  2. Dual-Energy CT: New Horizon in Medical Imaging

    PubMed Central

    Goo, Jin Mo

    2017-01-01

    Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector. PMID:28670151

  3. The comparative cost-effectiveness of colorectal cancer screening using faecal immunochemical test vs. colonoscopy.

    PubMed

    Wong, Martin C S; Ching, Jessica Y L; Chan, Victor C W; Sung, Joseph J Y

    2015-09-04

    Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC.

  4. The comparative cost-effectiveness of colorectal cancer screening using faecal immunochemical test vs. colonoscopy

    PubMed Central

    Wong, Martin CS; Ching, Jessica YL; Chan, Victor CW; Sung, Joseph JY

    2015-01-01

    Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC. PMID:26338314

  5. Radiosensitive orbital metastasis as presentation of occult colonic adenocarcinoma.

    PubMed

    Ludmir, Ethan B; McCall, Shannon J; Czito, Brian G; Palta, Manisha

    2014-09-19

    An 82-year-old man presented with progressive right frontal headaches. The patient's history was significant for benign polyps on surveillance colonoscopy 2 years prior, without high-grade dysplasia or carcinoma. MRI revealed an enhancing lesion arising within the superomedial aspect of the right orbit. Lesion biopsy demonstrated histological appearance and immunophenotype suggestive of colonic adenocarcinoma. Staging positron emission tomography/CT showed visceral metastases and diffuse activity in the posterior rectosigmoid, consistent with metastatic colon cancer. Treatment of the orbital lesion with external beam radiotherapy to 30 Gy resulted in significant palliation of the patient's headaches. The patient expired 2 months following treatment completion due to disease progression. Orbital metastasis as the initial presentation of an occult colorectal primary lesion is exceedingly rare, and occurred in this patient despite surveillance colonoscopy. Radiotherapy remains an efficacious modality for treatment of orbital metastases. 2014 BMJ Publishing Group Ltd.

  6. [Colonic diverticular disease: diagnosis and therapy].

    PubMed

    Lakatos, László; Lakatos, Péter László

    2012-02-12

    Colonic diverticular disease is one of the most common gastrointestinal disorders in the Western world, affecting approximately 50% of the population above the age of 70 years. Symptoms develop only in about one quarter of the affected individuals with complications in one-third of the symptomatic patients. Diagnosis is mostly confirmed by colonoscopy. Abdominal CT is the most sensitive for the diagnosis of complicated severe diverticulitis, while colonoscopy or in severe cases angiography may be performed in bleeding patients. Initial therapy of non-complicated symptomatic diverticulitis includes antibiotics and more recently non-absorbable antibiotics. In complicated cases should be treated with broad spectrum i.v. antibiotics, however surgery may became necessary in a minority of the cases. The proportion of patients needing acute surgical intervention has decreased in the last decades with the advancement of conservative management including medical therapy, endoscopy and imaging techniques and the indication of elective was also changed.

  7. The utility of Google Trends data to examine interest in cancer screening.

    PubMed

    Schootman, M; Toor, A; Cavazos-Rehg, P; Jeffe, D B; McQueen, A; Eberth, J; Davidson, N O

    2015-06-08

    We examined the utility of January 2004 to April 2014 Google Trends data from information searches for cancer screenings and preparations as a complement to population screening data, which are traditionally estimated through costly population-level surveys. State-level data across the USA. Persons who searched for terms related to cancer screening using Google, and persons who participated in the Behavioral Risk Factor Surveillance System (BRFSS). (1) State-level Google Trends data, providing relative search volume (RSV) data scaled to the highest search proportion per week (RSV100) for search terms over time since 2004 and across different geographical locations. (2) RSV of new screening tests, free/low-cost screening for breast and colorectal cancer, and new preparations for colonoscopy (Prepopik). (3) State-level breast, cervical, colorectal and prostate cancer screening rates. Correlations between Google Trends and BRFSS data ranged from 0.55 for ever having had a colonoscopy to 0.14 for having a Pap smear within the past 3 years. Free/low-cost mammography and colonoscopy showed higher RSV during their respective cancer awareness months. RSV for Miralax remained stable, while interest in Prepopik increased over time. RSV for lung cancer screening, virtual colonoscopy and three-dimensional mammography was low. Google Trends data provides enormous scientific possibilities, but are not a suitable substitute for, but may complement, traditional data collection and analysis about cancer screening and related interests. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. Outreach invitations for FIT and colonoscopy improve colorectal cancer screening rates: A randomized controlled trial in a safety-net health system.

    PubMed

    Singal, Amit G; Gupta, Samir; Tiro, Jasmin A; Skinner, Celette Sugg; McCallister, Katharine; Sanders, Joanne M; Bishop, Wendy Pechero; Agrawal, Deepak; Mayorga, Christian A; Ahn, Chul; Loewen, Adam C; Santini, Noel O; Halm, Ethan A

    2016-02-01

    The effectiveness of colorectal cancer (CRC) screening is limited by underuse, particularly among underserved populations. Among a racially diverse and socioeconomically disadvantaged cohort of patients, the authors compared the effectiveness of fecal immunochemical test (FIT) outreach and colonoscopy outreach to increase screening participation rates, compared with usual visit-based care. Patients aged 50 to 64 years who were not up-to-date with CRC screening but used primary care services in a large safety-net health system were randomly assigned to mailed FIT outreach (2400 patients), mailed colonoscopy outreach (2400 patients), or usual care with opportunistic visit-based screening (1199 patients). Patients who did not respond to outreach invitations within 2 weeks received follow-up telephone reminders. The primary outcome was CRC screening completion within 12 months after randomization. Baseline patient characteristics across the 3 groups were similar. Using intention-to-screen analysis, screening participation rates were higher for FIT outreach (58.8%) and colonoscopy outreach (42.4%) than usual care (29.6%) (P <.001 for both). Screening participation with FIT outreach was higher than that for colonoscopy outreach (P <.001). Among responders, FIT outreach had a higher percentage of patients who responded before reminders (59.0% vs 29.7%; P <.001). Nearly one-half of patients in the colonoscopy outreach group crossed over to complete FIT via usual care, whereas <5% of patients in the FIT outreach group underwent usual-care colonoscopy. Mailed outreach invitations appear to significantly increase CRC screening rates among underserved populations. In the current study, FIT-based outreach was found to be more effective than colonoscopy-based outreach to increase 1-time screening participation. Studies with longer follow-up are needed to compare the effectiveness of outreach strategies for promoting completion of the entire screening process. © 2015 American Cancer Society.

  9. Implementation of a virtual laryngoscope system using efficient reconstruction algorithms.

    PubMed

    Luo, Shouhua; Yan, Yuling

    2009-08-01

    Conventional fiberoptic laryngoscope may cause discomfort to the patient and in some cases it can lead to side effects that include perforation, infection and hemorrhage. Virtual laryngoscopy (VL) can overcome this problem and further it may lower the risk of operation failures. Very few virtual endoscope (VE) based investigations of the larynx have been described in the literature. CT data sets from a healthy subject were used for the VL studies. An algorithm of preprocessing and region-growing for 3-D image segmentation is developed. An octree based approach is applied in our VL system which facilitates a rapid construction of iso-surfaces. Some locating techniques are used for fast rendering and navigation (fly-through). Our VL visualization system provides for real time and efficient 'fly-through' navigation. The virtual camera can be arranged so that it moves along the airway in either direction. Snap shots were taken during fly-throughs. The system can automatically adjust the direction of the virtual camera and prevent collisions of the camera and the wall of the airway. A virtual laryngoscope (VL) system using OpenGL (Open Graphics Library) platform for interactive rendering and 3D visualization of the laryngeal framework and upper airway is established. OpenGL is supported on major operating systems and works with every major windowing system. The VL system runs on regular PC workstations and was successfully tested and evaluated using CT data from a normal subject.

  10. Family history and the risk of colorectal cancer: The importance of patients' history of colonoscopy.

    PubMed

    Weigl, Korbinian; Jansen, Lina; Chang-Claude, Jenny; Knebel, Phillip; Hoffmeister, Michael; Brenner, Hermann

    2016-11-15

    Registry-based studies on the risk of colorectal cancer (CRC) for persons with a family history (FH) typically did not control for important covariates, such as history of colonoscopy. We aimed to quantify the association between FH and CRC risk, carefully accounting for potential confounders. We conducted a population-based case-control study in Germany. A total of 4,313 patients with a first diagnosis of CRC (cases) and 3,153 controls recruited from 2003 to 2014 were included. We used multiple logistic regression analyses to assess the association between FH and risk of CRC with odds ratios (OR) and the resulting 95% confidence intervals (95% CI). A total of 582 cases (13.5%) and 321 (10.2%) controls reported a history of CRC in a first-degree relative, which was associated with a 41% increase in risk of CRC (OR: 1.41, 95% CI 1.22-1.63) after adjustment for sex and age. The OR substantially increased to 1.73 (95% CI, 1.48-2.03) after comprehensive adjustment including previous colonoscopies. Irrespective of their FH status, persons with history of colonoscopies had a lower CRC risk compared with persons without previous colonoscopies and without family history (OR: 0.25, 95% CI, 0.22-0.28 for persons without FH and OR 0.45, 95% CI, 0.36-0.56 for persons with FH). In an era of widespread use of colonoscopy, adjusting for previous colonoscopy is therefore crucial for deriving valid estimates of FH-related CRC risk. Colonoscopy reduces the risk of CRC among those with FH far below levels of people with no FH and no colonoscopy. © 2016 UICC.

  11. Cost-Effectiveness of Patient Navigation to Increase Adherence with Screening Colonoscopy Among Minority Individuals

    PubMed Central

    Ladabaum, Uri; Mannalithara, Ajitha; Jandorf, Lina; Itzkowitz, Steven H.

    2015-01-01

    Background Colorectal cancer (CRC) screening is underutilized by minority populations. Patient navigation increases adherence with screening colonoscopy. We estimated the cost-effectiveness of navigation for screening colonoscopy from the perspective of a payer seeking to improve population health. Methods We informed our validated model of CRC screening with inputs from navigation studies in New York City (population 43% African American, 49% Hispanic, 4% White, 4% Other; base case screening 40% without and 65% with navigation, navigation costs $29/colonoscopy completer, $21/non-completer, $3/non-navigated). We compared: 1) navigation vs. no navigation for one-time screening colonoscopy in unscreened persons age ≥50; 2) programs of colonoscopy with vs. without navigation, vs. fecal occult blood testing (FOBT) or immunochemical testing (FIT) for ages 50-80. Results In the base case: 1) one-time navigation gained quality-adjusted life-years (QALYs) and decreased costs; 2) longitudinal navigation cost $9,800/QALY gained vs. no navigation, and assuming comparable uptake rates, it cost $118,700/QALY gained vs. FOBT, but was less effective and more costly than FIT. Results were most dependent on screening participation rates and navigation costs: 1) assuming a 5% increase in screening uptake with navigation and navigation cost of $150/completer, one-time navigation cost $26,400/QALY gained; 2) longitudinal navigation with 75% colonoscopy uptake cost <$25,000/QALY gained vs. FIT when FIT uptake was <50%. Probabilistic sensitivity analyses did not alter the conclusions. Conclusions Navigation for screening colonoscopy appears to be cost-effective, and one-time navigation may be cost-saving. In emerging healthcare models that reward outcomes, payers should consider covering the costs of navigation for screening colonoscopy. PMID:25492455

  12. Impact of bowel preparation on surveillance colonoscopy interval.

    PubMed

    Singhal, Shashideep; Virk, Muhammad Asif; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury

    2014-07-01

    Atpresent there are no guidelines for colonoscopy surveillance interval in subjects with unsatisfactory bowel preparation. Study was designed to compare outcomes of repeat colonoscopy at different surveillance intervals in patients with unsatisfactory preparation on index exam. Ten thousand nine hundred and eight colonoscopies were done during the study period. Patients with index colonoscopy exam complete up to cecum but suboptimal bowel prep were included. Two hundred and ninety-seven patients met the inclusion criteria. The interval for repeat colonoscopy was <1 year in 38.5%, 1-2 years in 33.3%, 2-3 years in 16.7%, and 3-5 years in 11.5% subjects. Adenoma detection rate (ADR) was 24%, high-risk adenoma detection rate (HR-ADR) was 8.4%, and colorectal cancer detection rate was 1.7%. The HR-ADR based on surveillance intervals <1 year, 1-2 years, 2-3 years, and 3-5 years was 8%, 7.9%, 2%, and 19.4%, respectively. The HR-ADR was significantly higher at surveillance interval 3-5 years (p < 0.05). Colonoscopies repeated at interval >3 years showed a significant HR-ADR. The study indicates that a surveillance interval of 3 years can be reasonable for subjects having an index colonoscopy with suboptimal/fair/poor bowel prep and complete colon examination. Colonoscopy should be repeated earlier if symptoms develop.

  13. Management of Patients with Acute Lower Gastrointestinal Bleeding

    PubMed Central

    Strate, Lisa L.; Gralnek, Ian M.

    2016-01-01

    This guideline provides recommendations for the management of patients with acute overt lower gastrointestinal hemorrhage. Hemodynamic status should be initially assessed with intravascular volume resuscitation started as needed. Risk stratification based upon clinical parameters should be performed to help distinguish patients at high and low-risk of adverse outcomes. Hematochezia associated with hemodynamic instability may be indicative of an upper GI bleeding source and thus warrants an upper endoscopy. In the majority of patients, colonoscopy should be the initial diagnostic procedure and should be performed within 24 hours of patient presentation after adequate colon preparation. Endoscopic hemostasis therapy should be provided to patients with high risk endoscopic stigmata of bleeding including active bleeding, non-bleeding visible vessel, or adherent clot. The endoscopic hemostasis modality used (mechanical, thermal, injection or combination) is most often guided by the etiology of bleeding, access to the bleeding site, and endoscopist experience with the various hemostasis modalities. Repeat colonoscopy, with endoscopic hemostasis performed if indicated, should be considered for patients with evidence of recurrent bleeding. Radiographic interventions (tagged red blood cell scintigraphy, CT angiography, angiography) should be considered in high-risk patients with ongoing bleeding who do not respond adequately to resuscitation, and who are unlikely to tolerate bowel preparation and colonoscopy. Strategies to prevent recurrent bleeding should be considered. NSAID use should be avoided in patients with a history of acute lower GI bleeding particularly if secondary to diverticulosis or angioectasia. In patients with established cardiovascular disease who require aspirin (secondary prophylaxis), aspirin should not be discontinued. The exact timing depends on the severity of bleeding, perceived adequacy of hemostasis and the risk of a thromboembolic event. Surgery for the prevention of recurrent lower gastrointestinal bleeding should be individualized and the source of bleeding should be carefully localized prior to resection. PMID:26925883

  14. Classifying the Indication for Colonoscopy Procedures: A Comparison of NLP Approaches in a Diverse National Healthcare System.

    PubMed

    Patterson, Olga V; Forbush, Tyler B; Saini, Sameer D; Moser, Stephanie E; DuVall, Scott L

    2015-01-01

    In order to measure the level of utilization of colonoscopy procedures, identifying the primary indication for the procedure is required. Colonoscopies may be utilized not only for screening, but also for diagnostic or therapeutic purposes. To determine whether a colonoscopy was performed for screening, we created a natural language processing system to identify colonoscopy reports in the electronic medical record system and extract indications for the procedure. A rule-based model and three machine-learning models were created using 2,000 manually annotated clinical notes of patients cared for in the Department of Veterans Affairs. Performance of the models was measured and compared. Analysis of the models on a test set of 1,000 documents indicates that the rule-based system performance stays fairly constant as evaluated on training and testing sets. However, the machine learning model without feature selection showed significant decrease in performance. Therefore, rule-based classification system appears to be more robust than a machine-learning system in cases when no feature selection is performed.

  15. A Virtual Learning Environment for Part-Time MASW Students: An Evaluation of the WebCT

    ERIC Educational Resources Information Center

    Chan, Charles C.; Tsui, Ming-sum; Chan, Mandy Y. C.; Hong, Joe H.

    2008-01-01

    This study aims to evaluate the perception of a cohort of social workers studying for a part-time master's program in social work in using the popular Web-based learning platform--World Wide Web Course Tools (WebCT) as a complimentary method of teaching and learning. It was noted that social work profession began incorporating computer technology…

  16. [Virtual bronchoscopy: the correlation between endoscopic simulation and bronchoscopic findings].

    PubMed

    Salvolini, L; Gasparini, S; Baldelli, S; Bichi Secchi, E; Amici, F

    1997-11-01

    We carried out a preliminary clinical validation of 3D spiral CT virtual endoscopic reconstructions of the tracheobronchial tree, by comparing virtual bronchoscopic images with actual endoscopic findings. Twenty-two patients with tracheobronchial disease suspected at preliminary clinical, cytopathological and plain chest film findings were submitted to spiral CT of the chest and bronchoscopy. CT was repeated after endobronchial therapy in 2 cases. Virtual endoscopic shaded-surface-display views of the tracheobronchial tree were reconstructed from reformatted CT data with an Advantage Navigator software. Virtual bronchoscopic images were preliminarily evaluated with a semi-quantitative quality score (excellent/good/fair/poor). The depiction of consecutive airway branches was then considered. Virtual bronchoscopies were finally submitted to double-blind comparison with actual endoscopies. Virtual image quality was considered excellent in 8 cases, good in 14 and fair in 2. Virtual exploration was stopped at the lobar bronchi in one case only; the origin of segmental bronchi was depicted in 23 cases and that of some subsegmental branches in 2 cases. Agreement between actual and virtual bronchoscopic findings was good in all cases but 3 where it was nevertheless considered satisfactory. The yield of clinically useful information differed in 8/24 cases: virtual reconstructions provided more information than bronchoscopy in 5 cases and vice versa in 3. Virtual reconstructions are limited in that the procedure is long and difficult and needing a strictly standardized threshold value not to alter virtual findings. Moreover, the reconstructed surface lacks transparency, there is the partial volume effect and the branches < or = 4 pixels phi and/or meandering ones are difficult to explore. Our preliminary data are encouraging. Segmental bronchi were depicted in nearly all cases, except for the branches involved by disease. Obstructing lesions could be bypassed in some cases, making an indication for endoscopic laser therapy. Future didactic perspectives and applications to minimally invasive or virtual reality-assisted therapy seem promising, even though actual clinical applications require further studies.

  17. Generation of realistic virtual nodules based on three-dimensional spatial resolution in lung computed tomography: A pilot phantom study.

    PubMed

    Narita, Akihiro; Ohkubo, Masaki; Murao, Kohei; Matsumoto, Toru; Wada, Shinichi

    2017-10-01

    The aim of this feasibility study using phantoms was to propose a novel method for obtaining computer-generated realistic virtual nodules in lung computed tomography (CT). In the proposed methodology, pulmonary nodule images obtained with a CT scanner are deconvolved with the point spread function (PSF) in the scan plane and slice sensitivity profile (SSP) measured for the scanner; the resultant images are referred to as nodule-like object functions. Next, by convolving the nodule-like object function with the PSF and SSP of another (target) scanner, the virtual nodule can be generated so that it has the characteristics of the spatial resolution of the target scanner. To validate the methodology, the authors applied physical nodules of 5-, 7- and 10-mm-diameter (uniform spheres) included in a commercial CT test phantom. The nodule-like object functions were calculated from the sphere images obtained with two scanners (Scanner A and Scanner B); these functions were referred to as nodule-like object functions A and B, respectively. From these, virtual nodules were generated based on the spatial resolution of another scanner (Scanner C). By investigating the agreement of the virtual nodules generated from the nodule-like object functions A and B, the equivalence of the nodule-like object functions obtained from different scanners could be assessed. In addition, these virtual nodules were compared with the real (true) sphere images obtained with Scanner C. As a practical validation, five types of laboratory-made physical nodules with various complicated shapes and heterogeneous densities, similar to real lesions, were used. The nodule-like object functions were calculated from the images of these laboratory-made nodules obtained with Scanner A. From them, virtual nodules were generated based on the spatial resolution of Scanner C and compared with the real images of laboratory-made nodules obtained with Scanner C. Good agreement of the virtual nodules generated from the nodule-like object functions A and B of the phantom spheres was found, suggesting the validity of the nodule-like object functions. The virtual nodules generated from the nodule-like object function A of the phantom spheres were similar to the real images obtained with Scanner C; the root mean square errors (RMSEs) between them were 10.8, 11.1, and 12.5 Hounsfield units (HU) for 5-, 7-, and 10-mm-diameter spheres, respectively. The equivalent results (RMSEs) using the nodule-like object function B were 15.9, 16.8, and 16.5 HU, respectively. These RMSEs were small considering the high contrast between the sphere density and background density (approximately 674 HU). The virtual nodules generated from the nodule-like object functions of the five laboratory-made nodules were similar to the real images obtained with Scanner C; the RMSEs between them ranged from 6.2 to 8.6 HU in five cases. The nodule-like object functions calculated from real nodule images would be effective to generate realistic virtual nodules. The proposed method would be feasible for generating virtual nodules that have the characteristics of the spatial resolution of the CT system used in each institution, allowing for site-specific nodule generation. © 2017 American Association of Physicists in Medicine.

  18. Comparison between different colon cleansing products for screening colonoscopy. A noninferiority trial in population-based screening programs in Italy.

    PubMed

    Zorzi, Manuel; Valiante, Flavio; Germanà, Bastianello; Baldassarre, Gianluca; Coria, Bartolomea; Rinaldi, Michela; Heras Salvat, Helena; Carta, Alessandra; Bortoluzzi, Francesco; Cervellin, Erica; Polo, Maria Luisa; Bulighin, Gianmarco; Azzurro, Maurizio; Di Piramo, Daniele; Turrin, Anna; Monica, Fabio

    2016-03-01

    The high volume and poor palatability of 4 L of polyethylene glycol (PEG)-based bowel cleansing preparation required before a colonoscopy represent a major obstacle for patients. The aim of this study was to compare two low volume PEG-based preparations with standard 4 L PEG in individuals with a positive fecal immunochemical test (FIT) within organized screening programs in Italy. A total of 3660 patients with a positive FIT result were randomized to receive, in a split-dose regimen, 4 L PEG or 2 L PEG plus ascorbate (PEG-A) or 2 L PEG with citrate and simethicone plus bisacodyl (PEG-CS). The noninferiority of the low volume preparations vs. 4 L PEG was tested through the difference in proportions of adequate cleansing. A total of 2802 patients were included in the study. Adequate bowel cleansing was achieved in 868 of 926 cases (93.7 %) in the 4 L PEG group, in 872 out of 911 cases in the PEG-A group (95.7 %, difference in proportions  + 1.9 %, 95 % confidence interval [CI]  - 0.1 to 3.9), and in 862 out of 921 cases in the PEG-CS group (93.6 %, difference in proportions  - 0.2 %, 95 %CI  - 2.4 to 2.0). Bowel cleansing was adequate in 95.5 % of cases when the preparation-to-colonoscopy interval was between 120 and 239 minutes, whereas it dropped to 83.3 % with longer intervals. Better cleansing was observed in patients with regular bowel movements (95.6 %) compared with those with diarrhea (92.4 %) or constipation (90.8 %). Low volume PEG-based preparations administered in a split-dose regimen guarantee noninferior bowel cleansing compared with 4 L PEG. Constipated patients require a personalized preparation. EudraCT 2012 - 003958 - 82. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Helical CT scan with 2D and 3D reconstructions and virtual endoscopy versus conventional endoscopy in the assessment of airway disease in neonates, infants and children.

    PubMed

    Yunus, Mahira

    2012-11-01

    To study the use of helical computed tomography 2-D and 3-D images, and virtual endoscopy in the evaluation of airway disease in neonates, infants and children and its value in lesion detection, characterisation and extension. Conducted at Al-Noor Hospital, Makkah, Saudi Arabia, from January 1 to June 30, 2006, the study comprised of 40 patients with strider, having various causes of airway obstruction. They were examined by helical CT scan with 2-D and 3-D reconstructions and virtual endoscopy. The level and characterisation of lesions were carried out and results were compared with actual endoscopic findings. Conventional endoscopy was chosen as the gold standard, and the evaluation of endoscopy was done in terms of sensitivity and specificity of the procedure. For statistical purposes, SPSS version 10 was used. All CT methods detected airway stenosis or obstruction. Accuracy was 98% (n=40) for virtual endoscopy, 96% (n=48) for 3-D external rendering, 90% (n=45) for multiplanar reconstructions and 86% (n=43) for axial images. Comparing the results of 3-D internal and external volume rendering images with conventional endoscopy for detection and grading of stenosis were closer than with 2-D minimum intensity multiplanar reconstruction and axial CT slices. Even high-grade stenosis could be evaluated with virtual endoscope through which conventional endoscope cannot be passed. A case of 4-year-old patient with tracheomalacia could not be diagnosed by helical CT scan and virtual bronchoscopy which was diagriosed on conventional endoscopy and needed CT scan in inspiration and expiration. Virtual endoscopy [VE] enabled better assessment of stenosis compared to the reading of 3-D external rendering, 2-D multiplanar reconstruction [MPR] or axial slices. It can replace conventional endoscopy in the assessment of airway disease without any additional risk.

  20. Image quality characteristics for virtual monoenergetic images using dual-layer spectral detector CT: Comparison with conventional tube-voltage images.

    PubMed

    Sakabe, Daisuke; Funama, Yoshinori; Taguchi, Katsuyuki; Nakaura, Takeshi; Utsunomiya, Daisuke; Oda, Seitaro; Kidoh, Masafumi; Nagayama, Yasunori; Yamashita, Yasuyuki

    2018-05-01

    To investigate the image quality characteristics for virtual monoenergetic images compared with conventional tube-voltage image with dual-layer spectral CT (DLCT). Helical scans were performed using a first-generation DLCT scanner, two different sizes of acrylic cylindrical phantoms, and a Catphan phantom. Three different iodine concentrations were inserted into the phantom center. The single-tube voltage for obtaining virtual monoenergetic images was set to 120 or 140 kVp. Conventional 120- and 140-kVp images and virtual monoenergetic images (40-200-keV images) were reconstructed from slice thicknesses of 1.0 mm. The CT number and image noise were measured for each iodine concentration and water on the 120-kVp images and virtual monoenergetic images. The noise power spectrum (NPS) was also calculated. The iodine CT numbers for the iodinated enhancing materials were similar regardless of phantom size and acquisition method. Compared with the iodine CT numbers of the conventional 120-kVp images, those for the monoenergetic 40-, 50-, and 60-keV images increased by approximately 3.0-, 1.9-, and 1.3-fold, respectively. The image noise values for each virtual monoenergetic image were similar (for example, 24.6 HU at 40 keV and 23.3 HU at 200 keV obtained at 120 kVp and 30-cm phantom size). The NPS curves of the 70-keV and 120-kVp images for a 1.0-mm slice thickness over the entire frequency range were similar. Virtual monoenergetic images represent stable image noise over the entire energy spectrum and improved the contrast-to-noise ratio than conventional tube voltage using the dual-layer spectral detector CT. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Screening for Colorectal Cancer With Fecal Immunochemical Testing With and Without Postpolypectomy Surveillance Colonoscopy: A Cost-Effectiveness Analysis.

    PubMed

    Greuter, Marjolein J E; de Klerk, Clasine M; Meijer, Gerrit A; Dekker, Evelien; Coupé, Veerle M H

    2017-10-17

    Population-based screening to prevent colorectal cancer (CRC) death is effective, but the effectiveness of postpolypectomy surveillance is unclear. To evaluate the additional benefit in terms of cost-effectiveness of colonoscopy surveillance in a screening setting. Microsimulation using the ASCCA (Adenoma and Serrated pathway to Colorectal CAncer) model. Dutch CRC screening program and published literature. Asymptomatic persons aged 55 to 75 years without a prior CRC diagnosis. Lifetime. Health care payer. Fecal immunochemical test (FIT) screening with colonoscopy surveillance performed according to the Dutch guideline was simulated. The comparator was no screening or surveillance. FIT screening without colonoscopy surveillance and the effect of extending surveillance intervals were also evaluated. CRC burden, colonoscopy demand, life-years, and costs. FIT screening without surveillance reduced CRC mortality by 50.4% compared with no screening or surveillance. Adding surveillance to FIT screening reduced mortality by an additional 1.7% to 52.1% but increased lifetime colonoscopy demand by 62% (from 335 to 543 colonoscopies per 1000 persons) at an additional cost of €68 000, for an increase of 0.9 life-year. Extending the surveillance intervals to 5 years reduced CRC mortality by 51.8% and increased colonoscopy demand by 42.7% compared with FIT screening without surveillance. In an incremental analysis, incremental cost-effectiveness ratios (ICERs) for screening plus surveillance exceeded the Dutch willingness-to-pay threshold of €36 602 per life-year gained. When using a parameter set representing low colorectal lesion prevalence or when colonoscopy costs were halved or colorectal lesion incidence was doubled, screening plus surveillance became cost-effective compared with screening without surveillance. Limited data on FIT performance and background CRC risk in the surveillance population. Adding surveillance to FIT screening is not cost-effective based on the Dutch ICER threshold and substantially increases colonoscopy demand. Extending surveillance intervals to 5 years would decrease colonoscopy demand without substantial loss of effectiveness. Alpe d'HuZes, Dutch Cancer Society, and Stand Up To Cancer.

  2. The accuracy of colonoscopic localisation of colorectal tumours: a prospective, multi-centred observational study.

    PubMed

    Johnstone, M S; Moug, S J

    2014-05-01

    Colonoscopy is essential for accurate pre-operative colorectal tumour localisation, but its accuracy for localisation remains undetermined due to limitations of previous work. This study aimed to establish the accuracy of colonoscopic localisation and to determine how frequently inaccuracy results in altered surgical management. A prospective, multi-centred, powered observational study recruited 79 patients with colorectal tumours that underwent curative surgical resection. Patient and colonoscopic factors were recorded. Pre-operative colonoscopic and radiological lesion localisations were compared to intra-operative localisation using pre-defined anatomical bowel segments to determine accuracy, with changes in planned surgical management documented. Colonoscopy accurately located the colorectal tumour in 64/79 patients (81%). Five out of 15 inaccurately located patients required on-table alteration in planned surgical management. Pre-operative imaging was unable to visualise the primary tumour in 23.1% of cases, a finding that was more prevalent amongst bowel screener patients compared to symptomatic patients (45.8% vs. 13%; p = 0.003). Colonoscopic lesion localisation is inaccurate in 19.0% of cases and occurred throughout the colon with a change in on-table surgical management in 6.3%. With CT unable to visualise lesions in just under a quarter of cases, particularly in the screening population, preoperative localisation is heavily reliant on colonoscopy.

  3. Colonoscopy quality assurance in Ontario: Systematic review and clinical practice guideline

    PubMed Central

    Tinmouth, Jill; Kennedy, Erin B; Baron, David; Burke, Mae; Feinberg, Stanley; Gould, Michael; Baxter, Nancy; Lewis, Nancy

    2014-01-01

    Colonoscopy is fundamental to the diagnosis and management of digestive diseases and plays a key role in colorectal cancer (CRC) screening and diagnosis. Therefore, it is important to ensure that colonoscopy is of high quality. The present guidance document updates the evidence and recommendations in Cancer Care Ontario’s 2007 Colonoscopy Standards, and was conducted under the aegis of the Program in Evidence-Based Care. It is intended to support quality improvement for colonoscopies for all indications, including follow-up to a positive fecal occult blood test, screening for individuals who have a family history of CRC and those at average risk, investigation for symptomatic patients, and surveillance of those with a history of adenomatous polyps or CRC. A systematic review was performed to evaluate the existing evidence concerning the following three key aspects of colonoscopy: physician endoscopist training and maintenance of competency; institutional quality assurance parameters; and colonoscopy quality indicators and auditable outcomes. Where appropriate, indicators were designated quality indicators (where there was sufficient evidence to recommend a specific target) and auditable outcomes (insufficient evidence to recommend a specific target, but which should be monitored for quality assurance purposes). The guidance document may be used to support colonoscopy quality assurance programs to improve the quality of colonoscopy regardless of indication. Improvements in colonoscopy quality are anticipated to improve important outcomes in digestive diseases, such as reduction of the incidence of and mortality from CRC. PMID:24839621

  4. High-performance computer aided detection system for polyp detection in CT colonography with fluid and fecal tagging

    NASA Astrophysics Data System (ADS)

    Liu, Jiamin; Wang, Shijun; Kabadi, Suraj; Summers, Ronald M.

    2009-02-01

    CT colonography (CTC) is a feasible and minimally invasive method for the detection of colorectal polyps and cancer screening. Computer-aided detection (CAD) of polyps has improved consistency and sensitivity of virtual colonoscopy interpretation and reduced interpretation burden. A CAD system typically consists of four stages: (1) image preprocessing including colon segmentation; (2) initial detection generation; (3) feature selection; and (4) detection classification. In our experience, three existing problems limit the performance of our current CAD system. First, highdensity orally administered contrast agents in fecal-tagging CTC have scatter effects on neighboring tissues. The scattering manifests itself as an artificial elevation in the observed CT attenuation values of the neighboring tissues. This pseudo-enhancement phenomenon presents a problem for the application of computer-aided polyp detection, especially when polyps are submerged in the contrast agents. Second, general kernel approach for surface curvature computation in the second stage of our CAD system could yield erroneous results for thin structures such as small (6-9 mm) polyps and for touching structures such as polyps that lie on haustral folds. Those erroneous curvatures will reduce the sensitivity of polyp detection. The third problem is that more than 150 features are selected from each polyp candidate in the third stage of our CAD system. These high dimensional features make it difficult to learn a good decision boundary for detection classification and reduce the accuracy of predictions. Therefore, an improved CAD system for polyp detection in CTC data is proposed by introducing three new techniques. First, a scale-based scatter correction algorithm is applied to reduce pseudo-enhancement effects in the image pre-processing stage. Second, a cubic spline interpolation method is utilized to accurately estimate curvatures for initial detection generation. Third, a new dimensionality reduction classifier, diffusion map and local linear embedding (DMLLE), is developed for classification and false positives (FP) reduction. Performance of the improved CAD system is evaluated and compared with our existing CAD system (without applying those techniques) using CT scans of 1186 patients. These scans are divided into a training set and a test set. The sensitivity of the improved CAD system increased 18% on training data at a rate of 5 FPs per patient and 15% on test data at a rate of 5 FPs per patient. Our results indicated that the improved CAD system achieved significantly better performance on medium-sized colonic adenomas with higher sensitivity and lower FP rate in CTC.

  5. Cadaver-specific CT scans visualized at the dissection table combined with virtual dissection tables improve learning performance in general gross anatomy.

    PubMed

    Paech, Daniel; Giesel, Frederik L; Unterhinninghofen, Roland; Schlemmer, Heinz-Peter; Kuner, Thomas; Doll, Sara

    2017-05-01

    The purpose of this study was to quantify the benefit of the incorporation of radiologic anatomy (RA), in terms of student training in RA seminars, cadaver CT scans and life-size virtual dissection tables on the learning success in general anatomy. Three groups of a total of 238 students were compared in a multiple choice general anatomy exam during first-year gross anatomy: (1) a group (year 2015, n 1  = 50) that received training in radiologic image interpretation (RA seminar) and additional access to cadaver CT scans (CT + seminar group); (2) a group (2011, n 2  = 90) that was trained in the RA seminar only (RA seminar group); (3) a group (2011, n 3  = 98) without any radiologic image interpretation training (conventional anatomy group). Furthermore, the students' perception of the new curriculum was assessed qualitatively through a survey. The average test score of the CT + seminar group (21.8 ± 5.0) was significantly higher when compared to both the RA seminar group (18.3 ± 5.0) and the conventional anatomy group (17.1 ± 4.7) (p < 0.001). The incorporation of cadaver CT scans and life-size virtual dissection tables significantly improved the performance of medical students in general gross anatomy. Medical imaging and virtual dissection should therefore be considered to be part of the standard curriculum of gross anatomy. • Students provided with cadaver CT scans achieved 27 % higher scores in anatomy. • Radiological education integrated into gross anatomy is highly appreciated by medical students. • Simultaneous physical and virtual dissection provide unique conditions to study anatomy.

  6. The NordICC Study: Rationale and design of a randomized trial on colonoscopy screening for colorectal cancer

    PubMed Central

    F.Kaminski, Michal; Bretthauer, Michael; Zauber, Ann G.; Kuipers, Ernst J.; Adami, Hans-Olov; van Ballegooijen, Marjolein; Regula, Jaroslaw; van Leerdam, Monique; Stefansson, Tryggvi; Påhlman, Lars; Dekker, Evelien; Hernán, Miguel A.; Garborg, Kjetil; Hoff, Geir

    2017-01-01

    Background While colonoscopy screening is widely used in several European countries and the United States, no randomised trials exist to quantify its benefits. The Nordic-European Initiative on Colorectal Cancer (NordICC) is a multinational, randomized controlled trial aiming at investigating the effect of colonoscopy screening on CRC incidence and mortality. This paper describes the rationale and design of the NordICC trial. Material and methods Men and women age 55 to 64 years are drawn from the population registries in the participating countries and randomly assigned to either once-only colonoscopy screening with removal of all detected lesions, or no screening (standard of care in the trial regions). All individuals are followed for 15 years after inclusion using dedicated national registries. Results The primary endpoints of the trial are cumulative CRC-specific death and CRC incidence during 15 years of follow up. We hypothesize a 50% CRC mortality-reducing efficacy of the colonoscopy intervention and predict 50% compliance, yielding a 25% mortality reduction among those invited to screening. For 90% power and a two-sided alpha level of 0.05, using a 2:1 randomisation, 45,600 individuals will be randomised to control, and 22,800 individuals to the colonoscopy group. Interim analyses of the effect of colonoscopy on CRC incidence and mortality will be performed at 10 years follow-up. Conclusions The aim of the NordICC trial is to quantify the effectiveness of population-based colonoscopy screening. This will allow development of evidence-based guidelines for CRC screening in the general population. PMID:22723185

  7. Patient Navigation for Colonoscopy Completion: Results of an RCT.

    PubMed

    DeGroff, Amy; Schroy, Paul C; Morrissey, Kerry Grace; Slotman, Beth; Rohan, Elizabeth A; Bethel, James; Murillo, Jennifer; Ren, Weijia; Niwa, Shelley; Leadbetter, Steven; Joseph, Djenaba

    2017-09-01

    Colorectal cancer is a leading cause of cancer-related death in the U.S. Although screening reduces colorectal cancer incidence and mortality, screening rates among U.S. adults remain less than optimal, especially among disadvantaged populations. This study examined the efficacy of patient navigation to increase colonoscopy screening. RCT. A total of 843 low-income adults, primarily Hispanic and non-Hispanic blacks, aged 50-75 years referred for colonoscopy at Boston Medical Center were randomized into the intervention (n=429) or control (n=427) groups. Participants were enrolled between September 2012 and December 2014, with analysis following through 2015. Two bilingual lay navigators provided individualized education and support to reduce patient barriers and facilitate colonoscopy completion. The intervention was delivered largely by telephone. Colonoscopy completion within 6 months of study enrollment. Colonoscopy completion was significantly higher for navigated patients (61.1%) than control group patients receiving usual care (53.2%, p=0.021). Based on regression analysis, the odds of completing a colonoscopy for navigated patients was one and a half times greater than for controls (95% CI=1.12, 2.03, p=0.007). There were no differences between navigated and control groups in regard to adequacy of bowel preparation (95.3% vs 97.3%, respectively). Navigation significantly improved colonoscopy screening completion among a racially diverse, low-income population. Results contribute to mounting evidence demonstrating the efficacy of patient navigation in increasing colorectal cancer screening. Screening can be further enhanced when navigation is combined with other evidence-based practices implemented in healthcare systems and the community. Copyright © 2017. Published by Elsevier Inc.

  8. Improving compliance to colorectal cancer screening using blood and stool based tests in patients refusing screening colonoscopy in Germany.

    PubMed

    Adler, Andreas; Geiger, Sebastian; Keil, Anne; Bias, Harald; Schatz, Philipp; deVos, Theo; Dhein, Jens; Zimmermann, Mathias; Tauber, Rudolf; Wiedenmann, Bertram

    2014-10-17

    Despite strong recommendations for colorectal cancer (CRC) screening, participation rates are low. Understanding factors that affect screening choices is essential to developing future screening strategies. Therefore, this study assessed patient willingness to use non-invasive stool or blood based screening tests after refusing colonoscopy. Participants were recruited during regular consultations. Demographic, health, psychological and socioeconomic factors were recorded. All subjects were advised to undergo screening by colonoscopy. Subjects who refused colonoscopy were offered a choice of non-invasive tests. Subjects who selected stool testing received a collection kit and instructions; subjects who selected plasma testing had a blood draw during the office visit. Stool samples were tested with the Hb/Hp Complex Elisa test, and blood samples were tested with the Epi proColon® 2.0 test. Patients who were positive for either were advised to have a diagnostic colonoscopy. 63 of 172 subjects were compliant to screening colonoscopy (37%). 106 of the 109 subjects who refused colonoscopy accepted an alternative non-invasive method (97%). 90 selected the Septin9 blood test (83%), 16 selected a stool test (15%) and 3 refused any test (3%). Reasons for blood test preference included convenience of an office draw, overall convenience and less time consuming procedure. 97% of subjects refusing colonoscopy accepted a non-invasive screening test of which 83% chose the Septin9 blood test. The observation that participation can be increased by offering non-invasive tests, and that a blood test is the preferred option should be validated in a prospective trial in the screening setting.

  9. [Colonoscopy quality control as a requirement of colorectal cancer screening].

    PubMed

    Quintero, Enrique; Alarcón-Fernández, Onofre; Jover, Rodrigo

    2013-11-01

    The strategies used in population-based colorectal screening strategies culminate in colonoscopy and consequently the success of these programs largely depends on the quality of this diagnostic test. The main factors to consider when evaluating quality are scientific-technical quality, safety, patient satisfaction, and accessibility. Quality indicators allow variability among hospitals, endoscopy units and endoscopists to be determined and can identify those not achieving recommended standards. In Spain, the working group for colonoscopy quality of the Spanish Society of Gastroenterology and the Spanish Society of Gastrointestinal Endoscopy have recently drawn up a Clinical Practice Guideline that contains the available evidence on the quality of screening colonoscopy, as well as the basic requirements that must be met by endoscopy units and endoscopists carrying out this procedure. The implementation of training programs and screening colonoscopy quality controls are strongly recommended to guarantee the success of population-based colorectal cancer screening. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  10. Development of a Radiation Dose Reporting Software for X-ray Computed Tomography (CT)

    NASA Astrophysics Data System (ADS)

    Ding, Aiping

    X-ray computed tomography (CT) has experienced tremendous technological advances in recent years and has established itself as one of the most popular diagnostic imaging tools. While CT imaging clearly plays an invaluable role in modern medicine, its rapid adoption has resulted in a dramatic increase in the average medical radiation exposure to the worldwide and United States populations. Existing software tools for CT dose estimation and reporting are mostly based on patient phantoms that contain overly simplified anatomies insufficient in meeting the current and future needs. This dissertation describes the development of an easy-to-use software platform, “VirtualDose”, as a service to estimate and report the organ dose and effective dose values for patients undergoing the CT examinations. “VirtualDose” incorporates advanced models for the adult male and female, pregnant women, and children. To cover a large portion of the ignored obese patients that frequents the radiology clinics, a new set of obese male and female phantoms are also developed and applied to study the effects of the fat tissues on the CT radiation dose. Multi-detector CT scanners (MDCT) and clinical protocols, as well as the most recent effective dose algorithms from the International Commission on Radiological Protection (ICRP) Publication 103 are adopted in “VirtualDose” to keep pace with the MDCT development and regulatory requirements. A new MDCT scanner model with both body and head bowtie filter is developed to cover both the head and body scanning modes. This model was validated through the clinical measurements. A comprehensive slice-by-slice database is established by deriving the data from a larger number of single axial scans simulated on the patient phantoms using different CT bowtie filters, beam thicknesses, and different tube voltages in the Monte Carlo N-Particle Extended (MCNPX) code. When compared to the existing CT dose software packages, organ dose data in this software provides a better CT dose assessment by using anatomically realistic patient phantoms. All the related organ doses are incorporated into a standardized database compiled using Microsoft Structured Query Language (SQL) server 2008. Organ doses from contiguous axial or helical scans defined by a specific protocol can be rapidly obtained from the database. A next-generation software architecture and Active Server Pages (ASP) .NET framework are adopted to create a browser-hosted application to improve the user interactivity and reporting functionality including scanning parameter selection and organ dose reporting. “VirtualDose” has been developed as a web-based CT dose reporting platform to facilitate several important features including: (1) easy access via Internet; (2) no need for installation on the local computer; (3) a user-friendly, dynamic, browser-hosted graphical user interface; (4) use of advanced patient models for the adult male and female, pregnant women, children, and obese patient models; (5) adoption of modern CT scanners and protocols, as well as the most recent ICRP 103 effective dose algorithms; and (6) flexibility to manage and easily upgrade without impacting user’s usage.

  11. Crowd-assisted polyp annotation of virtual colonoscopy videos

    NASA Astrophysics Data System (ADS)

    Park, Ji Hwan; Nadeem, Saad; Marino, Joseph; Baker, Kevin; Barish, Matthew; Kaufman, Arie

    2018-03-01

    Virtual colonoscopy (VC) allows a radiologist to navigate through a 3D colon model reconstructed from a computed tomography scan of the abdomen, looking for polyps, the precursors of colon cancer. Polyps are seen as protrusions on the colon wall and haustral folds, visible in the VC y-through videos. A complete review of the colon surface requires full navigation from the rectum to the cecum in antegrade and retrograde directions, which is a tedious task that takes an average of 30 minutes. Crowdsourcing is a technique for non-expert users to perform certain tasks, such as image or video annotation. In this work, we use crowdsourcing for the examination of complete VC y-through videos for polyp annotation by non-experts. The motivation for this is to potentially help the radiologist reach a diagnosis in a shorter period of time, and provide a stronger confirmation of the eventual diagnosis. The crowdsourcing interface includes an interactive tool for the crowd to annotate suspected polyps in the video with an enclosing box. Using our work flow, we achieve an overall polyps-per-patient sensitivity of 87.88% (95.65% for polyps >=5mm and 70% for polyps <5mm). We also demonstrate the efficacy and effectiveness of a non-expert user in detecting and annotating polyps and discuss their possibility in aiding radiologists in VC examinations.

  12. Modestly increased use of colonoscopy when copayments are waived.

    PubMed

    Khatami, Shabnam; Xuan, Lei; Roman, Rolando; Zhang, Song; McConnel, Charles; Halm, Ethan A; Gupta, Samir

    2012-07-01

    Colorectal cancer (CRC) screening with colonoscopy often requires expensive copayments from patients. The 2010 Patient Protection and Affordable Care Act mandated elimination of copayments for CRC screening, including colonoscopy, but little is known about the effects of copayment elimination on use. The University of Texas employee, retiree, and dependent health plan instituted and promoted a waiver of copayments for screening colonoscopies in fiscal year (FY) 2009; we examined the effects of removing cost sharing on colonoscopy use. We conducted a retrospective cohort study of 59,855 beneficiaries of the University of Texas employee, retiree, and dependent health plan, associated with 16 University of Texas health and nonhealth campuses, ages 50-64 years at any point in FYs 2002-2009 (267,191 person-years of follow-up evaluation). The primary outcome was colonoscopy incidence among individuals with no prior colonoscopy. We compared the age- and sex-standardized incidence ratios for colonoscopy in FY 2009 (after the copayment waiver) with the expected incidence for FY 2009, based on secular trends from years before the waiver. The annual incidence of colonoscopy increased to 9.5% after the copayment was waived, compared with an expected incidence of 8.0% (standardized incidence ratio, 1.18; 95% confidence interval, 1.14-1.23; P < .001). After adjusting for age, sex, and beneficiary status, the copayment waiver remained significantly associated with greater use of colonoscopy, with an adjusted hazard ratio of 1.19 (95% confidence interval, 1.12-1.26). Waiving copayments for colonoscopy screening results in a statistically significant, but modest (1.5%), increase in use. Additional strategies beyond removing financial disincentives are needed to increase use of CRC screening. Copyright © 2012 AGA Institute. Published by Elsevier Inc. All rights reserved.

  13. Modestly Increased Use of Colonoscopy When Copayments Are Waived

    PubMed Central

    KHATAMI, SHABNAM; XUAN, LEI; ROMAN, ROLANDO; ZHANG, SONG; McCONNEL, CHARLES; HALM, ETHAN A.; GUPTA, SAMIR

    2012-01-01

    BACKGROUND & AIMS Colorectal cancer (CRC) screening with colonoscopy often requires expensive copayments from patients. The 2010 Patient Protection and Affordable Care Act mandated elimination of copayments for CRC screening, including colonoscopy, but little is known about the effects of copayment elimination on use. The University of Texas employee, retiree, and dependent health plan instituted and promoted a waiver of copayments for screening colonoscopies in fiscal year (FY) 2009; we examined the effects of removing cost sharing on colonoscopy use. METHODS We conducted a retrospective cohort study of 59,855 beneficiaries of the University of Texas employee, retiree, and dependent health plan, associated with 16 University of Texas health and nonhealth campuses, ages 50 – 64 years at any point in FYs 2002–2009 (267,191 person-years of follow-up evaluation). The primary outcome was colonoscopy incidence among individuals with no prior colonoscopy. We compared the age- and sex-standardized incidence ratios for colonoscopy in FY 2009 (after the copayment waiver) with the expected incidence for FY 2009, based on secular trends from years before the waiver. RESULTS The annual incidence of colonoscopy increased to 9.5% after the copayment was waived, compared with an expected incidence of 8.0% (standardized incidence ratio, 1.18; 95% confidence interval, 1.14 –1.23; P < .001). After adjusting for age, sex, and beneficiary status, the copayment waiver remained significantly associated with greater use of colonoscopy, with an adjusted hazard ratio of 1.19 (95% confidence interval, 1.12–1.26). CONCLUSIONS Waiving copayments for colonoscopy screening results in a statistically significant, but modest (1.5%), increase in use. Additional strategies beyond removing financial disincentives are needed to increase use of CRC screening. PMID:22401903

  14. Computed Tomography Colonography vs Colonoscopy for Colorectal Cancer Surveillance After Surgery.

    PubMed

    Weinberg, David S; Pickhardt, Perry J; Bruining, David H; Edwards, Kristin; Fletcher, Joel G; Gollub, Marc J; Keenan, Eileen M; Kupfer, Sonia S; Li, Tianyu; Lubner, Sam J; Markowitz, Arnold J; Ross, Eric A

    2018-03-01

    Recommendations for surveillance after curative surgery for colorectal cancer (CRC) include a 1-year post-resection abdominal-pelvic computed tomography (CT) scan and optical colonoscopy (OC). CT colonography (CTC), when used in CRC screening, effectively identifies colorectal polyps ≥10 mm and cancers. We performed a prospective study to determine whether CTC, concurrent with CT, could substitute for OC in CRC surveillance. Our study enrolled 231 patients with resected stage 0-III CRC, identified at 5 tertiary care academic centers. Approximately 1 year after surgery, participants underwent outpatient CTC plus CT, followed by same-day OC. CTC results were revealed after endoscopic visualization of sequential colonic segments, which were re-examined for discordant findings. The primary outcome was performance of CTC in the detection of colorectal adenomas and cancers using endoscopy as the reference standard. Of the 231 participants, 116 (50.2%) had polyps of any size or histology identified by OC, and 15.6% had conventional adenomas and/or serrated polyps ≥6 mm. No intra-luminal cancers were detected. CTC detected patients with polyps of ≥6 mm with 44.0% sensitivity (95% CI, 30.2-57.8) and 93.4% specificity (95% CI, 89.7-97.0). CTC detected polyps ≥10 mm with 76.9% sensitivity (95% CI, 54.0-99.8) and 89.0% specificity (95% CI, 84.8-93.1). Similar values were found when only adenomatous polyps were considered. The negative predictive value of CTC for adenomas ≥6 mm was 90.7% (95% CI, 86.7-94.5) and for adenomas ≥10 mm the negative predictive value was 98.6% (95% CI, 97.0-100). In a CRC surveillance population 1 year following resection, CTC was inferior to OC for detecting patients with polyps ≥6 mm. Clinical Trials.gov Registration Number: NCT02143115. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  15. Providing data for serrated polyp detection rate benchmarks: an analysis of the New Hampshire Colonoscopy Registry.

    PubMed

    Anderson, Joseph C; Butterly, Lynn F; Weiss, Julia E; Robinson, Christina M

    2017-06-01

    Similar to achieving adenoma detection rate (ADR) benchmarks to prevent colorectal cancer (CRC), achieving adequate serrated polyp detection rates (SDRs) may be essential to the prevention of CRC associated with the serrated pathway. Previous studies have been based on data from high-volume endoscopists at single academic centers. Based on a hypothesis that ADR is correlated with SDR, we stratified a large, diverse group of endoscopists (n = 77 practicing at 28 centers) into high performers and low performers, based on ADR, to provide data for corresponding target SDR benchmarks. By using colonoscopies in adults aged ≥50 years (4/09-12/14), we stratified endoscopists by high and low ADRs (<15%, 15%-<25%, 25%-<35%, ≥35%) to determine corresponding SDRs by using 2 SDR measures, for screening and surveillance colonoscopies separately: (1) Clinically significant SDR (CSSDR), meaning colonoscopies with any sessile serrated adenoma/polyp (SSA/P), traditional serrated adenoma (TSA), or hyperplastic polyp (HP) >1 cm anywhere in the colon or HP >5 mm in the proximal colon only divided by the total number of screening and surveillance colonoscopies, respectively. (2) Proximal SDR (PSDR) meaning colonoscopies with any serrated polyp (SSA/P, HP, TSA) of any size proximal to the sigmoid colon divided by the total number of screening and surveillance colonoscopies, respectively. A total of 45,996 (29,960 screening) colonoscopies by 77 endoscopists (28 facilities) were included. Moderately strong positive correlation coefficients were observed for screening ADR/CSSDR (P = .69) and ADR/PSDR (P = .79) and a strong positive correlation (P = .82) for CSSDR/PSDR (P < .0001 for all) was observed. For ADR ≥25%, endoscopists' median (interquartile range) screening CSSDR was 6.8% (4.3%-8.6%) and PSDR was 10.8% (8.6%-16.1%). Derived from ADR, the primary colonoscopy quality indicator, our results suggest potential SDR benchmarks (CSSDR = 7% and PSDR = 11%) that may guide adequate serrated polyp detection. Because CSSDR and PSDR are strongly correlated, endoscopists could use the simpler PSDR calculation to assess quality. Published by Elsevier Inc.

  16. Dual energy computed tomography for the head.

    PubMed

    Naruto, Norihito; Itoh, Toshihide; Noguchi, Kyo

    2018-02-01

    Dual energy CT (DECT) is a promising technology that provides better diagnostic accuracy in several brain diseases. DECT can generate various types of CT images from a single acquisition data set at high kV and low kV based on material decomposition algorithms. The two-material decomposition algorithm can separate bone/calcification from iodine accurately. The three-material decomposition algorithm can generate a virtual non-contrast image, which helps to identify conditions such as brain hemorrhage. A virtual monochromatic image has the potential to eliminate metal artifacts by reducing beam-hardening effects. DECT also enables exploration of advanced imaging to make diagnosis easier. One such novel application of DECT is the X-Map, which helps to visualize ischemic stroke in the brain without using iodine contrast medium.

  17. A case of leptospirosis simulating colon cancer with liver metastases

    PubMed Central

    Granito, Alessandro; Ballardini, Giorgio; Fusconi, Marco; Volta, Umberto; Muratori, Paolo; Sambri, Vittorio; Battista, Giuseppe; Bianchi, Francesco B.

    2004-01-01

    We report a case of a 61-year-old man who presented with fatigue, abdominal pain and hepatomegaly. Computed tomography (CT) of the abdomen showed hepatomegaly and multiple hepatic lesions highly suggestive of metastatic diseases. Due to the endoscopic finding of colon ulcer, colon cancer with liver metastases was suspected. Biochemically a slight increase of transaminases, alkaline phosphatase and gammaglutamyl transpeptidase were present; α - fetoprotein, carcinoembryogenic antigen and carbohydrate 19-9 antigen serum levels were normal. Laboratory and instrumental investigations, including colon and liver biopsies revealed no signs of malignancy. In the light of spontaneous improvement of symptoms and CT findings, his personal history was revaluated revealing direct contact with pigs and their tissues. Diagnosis of leptospirosis was considered and confirmed by detection of an elevated titer of antibodies to leptospira. After two mo, biochemical data, CT and colonoscopy were totally normal. PMID:15285043

  18. Promoting colorectal cancer screening through group education in community-based settings.

    PubMed

    Crookes, Danielle M; Njoku, Ogo; Rodriguez, Maria Carina; Mendez, Elsa Iris; Jandorf, Lina

    2014-06-01

    National colonoscopy adherence rates near 65% and New York City (NYC) colonoscopy rates approach 69%. Despite an overall increase in national colorectal cancer (CRC) screening rates, rates of CRC screening among Blacks and Latinos are lower than non-Latino Whites. We developed two group level, culturally targeted educational programs about CRC for Blacks and Latinos. One hour programs included education about screening, peer testimony given by a colonoscopy-adherent person, and pre- and post-knowledge assessment. From 2010 to 2012, we conducted 66 education programs in NYC, reaching 1,065 participants, 62.7% of whom were 50 years of age or older identified as Black or Latino and provided information about colonoscopy history (N = 668). Colonoscopy adherence in the sample was 69.3%. There was a significant increase in mean knowledge score about CRC and CRC screening from pretest to posttest. Sixty-eight percent of attendees without prior colonoscopy reported intent to schedule a colonoscopy as a result of attending the program. Culturally targeted education programs with peer testimony are a valuable way to raise awareness about CRC and colonoscopy and can influence intent to screen among nonadherent persons. Additional research is needed to establish group level education as an effective means of promoting CRC screening.

  19. Increasing referral rate for screening colonoscopy through patient education and activation at a primary care clinic in New York City.

    PubMed

    Sriphanlop, Pathu; Hennelly, Marie Oliva; Sperling, Dylan; Villagra, Cristina; Jandorf, Lina

    2016-08-01

    Colorectal cancer could be prevented through regular screening. Individuals age 50 and older are recommended to get screened via colonoscopy. Because physician referral is a major predictor of colonoscopy completion, two low-cost, evidence-based interventions were tested to increase referrals by activating patients to self-advocate. This study compared the impact of a pre-visit educational handout that prompts patients to discuss colonoscopy with their physician with the handout plus brief counseling through exit interviews and chart reviews. The main outcome was physician referral. Medical charts were reviewed for eligibility: 130 control patients (Arm 1), 45 patients who received the educational handout and health counseling (Arm 2), and 50 patients who received only the handout (Arm 3). Colonoscopy referral rates increased from 24.6% in Arm 1 to 44.4% and 52.0% in Arms 2 and 3, respectively (p=0.001). The proportion of exit interview participants who discussed colonoscopy with their doctor increased from 68.8% in Arm 1 to 76.5% and 88.9% in Arms 2 and 3, respectively. Results indicate that both interventions are effective at increasing colonoscopy referrals. Results suggest that an educational handout alone is sufficient in prompting patient-initiated discussions about colonoscopy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. [Preliminary safety and stability assessment of orthodontic miniscrew implantation guided by surgical template based on cone-beam CT images].

    PubMed

    Qiu, L L; Li, S; Bai, Y X

    2016-06-01

    To develop surgical templates for orthodontic miniscrew implantation based on cone-beam CT(CBCT)three-dimensional(3D)images and to evaluate the safety and stability of implantation guided by the templates. DICOM data obtained in patients who had CBCT scans taken were processed using Mimics software, and 3D images of teeth and maxillary bone were acquired. Meanwhile, 3D images of miniscrews were acquired using Solidworks software and processed with Mimics software. Virtual position of miniscrews was determined based on 3D images of teeth, bone, and miniscrews. 3D virtual templates were designed according to the virtual implantation plans. STL files were output and the real templates were fabricated with stereolithographic appliance(SLA). Postoperative CBCT scans were used to evaluate the implantation safety and the stability of miniscrews were investigated. All the templates were positioned accurately and kept stable throughout the implantation process. No root damage was found. The deviations were(1.73±0.65)mm at the corona, and(1.28±0.82)mm at the apex, respectively. The stability of miniscrews was fairly well. Surgical templates for miniscrew implantation could be acquired based on 3D CBCT images and fabricated with SLA. Implantation guided by these templates was safe and stable.

  1. Evaluation of colonoscopy technical skill levels by use of an objective kinematic-based system.

    PubMed

    Obstein, Keith L; Patil, Vaibhav D; Jayender, Jagadeesan; San José Estépar, Raúl; Spofford, Inbar S; Lengyel, Balazs I; Vosburgh, Kirby G; Thompson, Christopher C

    2011-02-01

    Colonoscopy requires training and experience to ensure accuracy and safety. Currently, no objective, validated process exists to determine when an endoscopist has attained technical competence. Kinematics data describing movements of laparoscopic instruments have been used in surgical skill assessment to define expert surgical technique. We have developed a novel system to record kinematics data during colonoscopy and quantitatively assess colonoscopist performance. To use kinematic analysis of colonoscopy to quantitatively assess endoscopic technical performance. Prospective cohort study. Tertiary-care academic medical center. This study involved physicians who perform colonoscopy. Application of a kinematics data collection system to colonoscopy evaluation. Kinematics data, validated task load assessment instrument, and technical difficulty visual analog scale. All 13 participants completed the colonoscopy to the terminal ileum on the standard colon model. Attending physicians reached the terminal ileum quicker than fellows (median time, 150.19 seconds vs 299.86 seconds; p<.01) with reduced path lengths for all 4 sensors, decreased flex (1.75 m vs 3.14 m; P=.03), smaller tip angulation, reduced absolute roll, and lower curvature of the endoscope. With performance of attending physicians serving as the expert reference standard, the mean kinematic score increased by 19.89 for each decrease in postgraduate year (P<.01). Overall, fellows experienced greater mental, physical, and temporal demand than did attending physicians. Small cohort size. Kinematic data and score calculation appear useful in the evaluation of colonoscopy technical skill levels. The kinematic score appears to consistently vary by year of training. Because this assessment is nonsubjective, it may be an improvement over current methods for determination of competence. Ongoing studies are establishing benchmarks and characteristic profiles of skill groups based on kinematics data. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  2. Sending family history questionnaires to patients before a colonoscopy improves genetic counseling for hereditary colorectal cancer.

    PubMed

    Kessels, Koen; Eisinger, Joey D; Letteboer, Tom G; Offerhaus, G Johan A; Siersema, Peter D; Moons, Leon M G

    2017-06-01

    To investigate whether sending a family history questionnaire to patients prior to undergoing colonoscopy results in an increased availability of family history and better genetic counseling. A questionnaire was mailed to patients before they underwent outpatient colonoscopy at a university hospital in 2013. These patients' additional characteristics and referral for genetic evaluation were retrieved from the electronic medical records. Patients undergoing inpatient coloboscopy, with confirmed hereditary colorectal cancer (CRC) or inflammatory bowel disease were excluded. All study patients from 2010 to 2013 were matched with the database of the genetics department to determine who consulted a geneticist. A total of 6163 patients underwent colonoscopy from 2010 to 2013. Of 1421 who underwent colonoscopy in 2013, 53 (3.7%) consulted a geneticist, while 75 (1.6%) of 4742 patients undergoing colonoscopy between 2010 and 2012 did so (P < 0.01). A total of 974 patients undergoing colonoscopy in 2013 were included to evaluate the completed questionnaire. Of these, 282 (29.0%) completed the questionnaire. Family history was not recorded in the electronic medical records of 393 (40.3%). In 129 (32.8%), family history was obtained from the completed questionnaire. In 2013, 49 (60.5%) out of 81 patients referred for genetic counseling were referred based on their family history. Eight (9.9%) patients were referred based on the completed questionnaire. Screening for hereditary CRC in a population undergoing outpatient colonoscopy with a questionnaire sent by mail resulted in an increased availability of family histories and genetic counseling. © 2017 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  3. Current state of micro-robots/devices as substitutes for screening colonoscopy: assessment based on technology readiness levels.

    PubMed

    Tapia-Siles, Silvia C; Coleman, Stuart; Cuschieri, Alfred

    2016-02-01

    Previous reports have described several candidates, which have the potential to replace colonoscopy, but to date, there is still no device capable of fully replacing flexible colonoscopy in the management of colonic disorders and for mass adult population screening for asymptomatic colorectal cancer. NASA developed the TRL methodology to describe and define the stages of development before use and marketing of any device. The definitions of the TRLS used in the present review are those formulated by "The US Department of Defense Technology Readiness Assessment Guidance" but adapted to micro-robots for colonoscopy. All the devices included are reported in scientific literature. They were identified by a systematic search in Web of Science, PubMed and IEEE Xplore amongst other sources. Devices that clearly lack the potential for full replacement of flexible colonoscopy were excluded. The technological salient features of all the devices included for assessment are described briefly, with particular focus on device propulsion. The devices are classified according to the TRL criteria based on the reported information. An analysis is next undertaken of the characteristics and salient features of the devices included in the review: wireless/tethered devices, data storage-transmission and navigation, additional functionality, residual technology challenges and clinical and socio-economical needs. Few devices currently possess the required functionality and performance to replace the conventional colonoscopy. The requirements, including functionalities which favour the development of a micro-robot platform to replace colonoscopy, are highlighted.

  4. Assessing resident performance and training of colonoscopy in a general surgery training program.

    PubMed

    Hope, William W; Hooks, W Borden; Kilbourne, S Nicole; Adams, Ashley; Kotwall, Cyrus A; Clancy, Thomas V

    2013-05-01

    Recently, the adequacy of endoscopy training in general surgery residency programs has been questioned. Efforts to improve resident endoscopic training and to judge competency are ongoing but not well studied. We assessed resident performance using two assessment tools in colonoscopy in a general surgery residency program. Prospectively collected data were reviewed from consecutive colonoscopies by a single surgeon: September 2008 to June 2011. Colonoscopies performed without residents were excluded. Data included patient demographics, procedural data, and outcomes. Following the colonoscopy, residents were graded by the attending surgeon using up two different assessment tools. Descriptive statistics were calculated and outcomes were compared. Colonoscopies were performed by residents in 100 patients. Average age was 52 (range, 22-79) years. Females made up 66 % of patients, and 63 % were Caucasian. Postgraduate level (PG-Y) 3 level residents performed 72 % of colonoscopies. The average resident participation was 73 % of the procedure. Biopsies were performed in 35 %; adenomatous polyps were found in 17 % and invasive cancer in 1 %. Bowel preparation was deemed good in 76 % of patients. Colonoscopy was completed in 90 % of patients. Reasons for incomplete exam were technical (7 patients), inability to pass a stricture (2 patients), and poor prep (1 patient). For completed full colonoscopies, the average time to reach the cecum was 22 min, and withdrawal time was 13 min. Resident assessments were made in 89 of the colonoscopies using 2 separate assessment tools. There were no mortalities; the morbidity rate was 3 %. Morbidities included a perforation related to a biopsy requiring surgery and partial colectomy, a postpolypectomy bleed requiring repeat colonoscopy with clipping of the bleeding vessel, and a patient with transient bradycardia requiring atropine during the procedure. Using objective assessment tools, overall resident skill and knowledge in performing colonoscopy appears to improve based on increasing PG-Y level, although this was not evident with all categories measured. Methods to assess competency continue to evolve and should be the focus of future research.

  5. Colonoscopy video quality assessment using hidden Markov random fields

    NASA Astrophysics Data System (ADS)

    Park, Sun Young; Sargent, Dusty; Spofford, Inbar; Vosburgh, Kirby

    2011-03-01

    With colonoscopy becoming a common procedure for individuals aged 50 or more who are at risk of developing colorectal cancer (CRC), colon video data is being accumulated at an ever increasing rate. However, the clinically valuable information contained in these videos is not being maximally exploited to improve patient care and accelerate the development of new screening methods. One of the well-known difficulties in colonoscopy video analysis is the abundance of frames with no diagnostic information. Approximately 40% - 50% of the frames in a colonoscopy video are contaminated by noise, acquisition errors, glare, blur, and uneven illumination. Therefore, filtering out low quality frames containing no diagnostic information can significantly improve the efficiency of colonoscopy video analysis. To address this challenge, we present a quality assessment algorithm to detect and remove low quality, uninformative frames. The goal of our algorithm is to discard low quality frames while retaining all diagnostically relevant information. Our algorithm is based on a hidden Markov model (HMM) in combination with two measures of data quality to filter out uninformative frames. Furthermore, we present a two-level framework based on an embedded hidden Markov model (EHHM) to incorporate the proposed quality assessment algorithm into a complete, automated diagnostic image analysis system for colonoscopy video.

  6. A Clear Liquid Diet Is Not Mandatory for Polyethylene Glycol-Based Bowel Preparation for Afternoon Colonoscopy in Healthy Outpatients

    PubMed Central

    Jung, Yoon Suk; Seok, Hyo Sun; Song, Chang Seok; Kim, Seong Eun; Lee, Suck Ho; Eun, Chang Soo; Han, Dong Soo; Kim, Yong Soo; Lee, Chang Kyun

    2013-01-01

    Background/Aims A dietary regimen consisting of a clear liquid diet (CLD) for at least 24 hours is recommended for colonoscopy preparation. However, this requirement results in problems in patient compliance with bowel preparation. The aim of this study was to evaluate the efficacy of a CLD compared with a regular diet (RD) for colonoscopy preparation using a polyethylene glycol (PEG) solution. Methods This was a multicenter, randomized, investigator-blind prospective study. A total of 801 healthy outpatients undergoing afternoon colonoscopy were randomized to either a CLD or RD in addition to a 4 L PEG regimen. Results The quality of bowel cleansing was not different between the CLD and RD groups in terms of the proportion with excellent or good preparation. In addition, no significant differences were observed between the two groups for polyp and adenoma detection rates and overall adverse events. Good compliance with bowel preparation was higher in the RD group than in the CLD group. Conclusions A CLD for a full day prior to colonoscopy should not be mandatory for PEG-based bowel preparation. Dietary education concerning the avoidance of high-fiber foods for 3 days before colonoscopy is sufficient, at least for healthy outpatients. PMID:24312709

  7. Automatic thoracic body region localization

    NASA Astrophysics Data System (ADS)

    Bai, PeiRui; Udupa, Jayaram K.; Tong, YuBing; Xie, ShiPeng; Torigian, Drew A.

    2017-03-01

    Radiological imaging and image interpretation for clinical decision making are mostly specific to each body region such as head & neck, thorax, abdomen, pelvis, and extremities. For automating image analysis and consistency of results, standardizing definitions of body regions and the various anatomic objects, tissue regions, and zones in them becomes essential. Assuming that a standardized definition of body regions is available, a fundamental early step needed in automated image and object analytics is to automatically trim the given image stack into image volumes exactly satisfying the body region definition. This paper presents a solution to this problem based on the concept of virtual landmarks and evaluates it on whole-body positron emission tomography/computed tomography (PET/CT) scans. The method first selects a (set of) reference object(s), segments it (them) roughly, and identifies virtual landmarks for the object(s). The geometric relationship between these landmarks and the boundary locations of body regions in the craniocaudal direction is then learned through a neural network regressor, and the locations are predicted. Based on low-dose unenhanced CT images of 180 near whole-body PET/CT scans (which includes 34 whole-body PET/CT scans), the mean localization error for the boundaries of superior of thorax (TS) and inferior of thorax (TI), expressed as number of slices (slice spacing ≍ 4mm)), and using either the skeleton or the pleural spaces as reference objects, is found to be 3,2 (using skeleton) and 3, 5 (using pleural spaces) respectively, or in mm 13, 10 mm (using skeleton) and 10.5, 20 mm (using pleural spaces), respectively. Improvements of this performance via optimal selection of objects and virtual landmarks and other object analytics applications are currently being pursued. and the skeleton and pleural spaces used as a reference objects

  8. A content-based image retrieval method for optical colonoscopy images based on image recognition techniques

    NASA Astrophysics Data System (ADS)

    Nosato, Hirokazu; Sakanashi, Hidenori; Takahashi, Eiichi; Murakawa, Masahiro

    2015-03-01

    This paper proposes a content-based image retrieval method for optical colonoscopy images that can find images similar to ones being diagnosed. Optical colonoscopy is a method of direct observation for colons and rectums to diagnose bowel diseases. It is the most common procedure for screening, surveillance and treatment. However, diagnostic accuracy for intractable inflammatory bowel diseases, such as ulcerative colitis (UC), is highly dependent on the experience and knowledge of the medical doctor, because there is considerable variety in the appearances of colonic mucosa within inflammations with UC. In order to solve this issue, this paper proposes a content-based image retrieval method based on image recognition techniques. The proposed retrieval method can find similar images from a database of images diagnosed as UC, and can potentially furnish the medical records associated with the retrieved images to assist the UC diagnosis. Within the proposed method, color histogram features and higher order local auto-correlation (HLAC) features are adopted to represent the color information and geometrical information of optical colonoscopy images, respectively. Moreover, considering various characteristics of UC colonoscopy images, such as vascular patterns and the roughness of the colonic mucosa, we also propose an image enhancement method to highlight the appearances of colonic mucosa in UC. In an experiment using 161 UC images from 32 patients, we demonstrate that our method improves the accuracy of retrieving similar UC images.

  9. Modeling Individual Patient Preferences for Colorectal Cancer Screening Based on Their Tolerance for Complications Risk.

    PubMed

    Taksler, Glen B; Perzynski, Adam T; Kattan, Michael W

    2017-04-01

    Recommendations for colorectal cancer screening encourage patients to choose among various screening methods based on individual preferences for benefits, risks, screening frequency, and discomfort. We devised a model to illustrate how individuals with varying tolerance for screening complications risk might decide on their preferred screening strategy. We developed a discrete-time Markov mathematical model that allowed hypothetical individuals to maximize expected lifetime utility by selecting screening method, start age, stop age, and frequency. Individuals could choose from stool-based testing every 1 to 3 years, flexible sigmoidoscopy every 1 to 20 years with annual stool-based testing, colonoscopy every 1 to 20 years, or no screening. We compared the life expectancy gained from the chosen strategy with the life expectancy available from a benchmark strategy of decennial colonoscopy. For an individual at average risk of colorectal cancer who was risk neutral with respect to screening complications (and therefore was willing to undergo screening if it would actuarially increase life expectancy), the model predicted that he or she would choose colonoscopy every 10 years, from age 53 to 73 years, consistent with national guidelines. For a similar individual who was moderately averse to screening complications risk (and therefore required a greater increase in life expectancy to accept potential risks of colonoscopy), the model predicted that he or she would prefer flexible sigmoidoscopy every 12 years with annual stool-based testing, with 93% of the life expectancy benefit of decennial colonoscopy. For an individual with higher risk aversion, the model predicted that he or she would prefer 2 lifetime flexible sigmoidoscopies, 20 years apart, with 70% of the life expectancy benefit of decennial colonoscopy. Mathematical models may formalize how individuals with different risk attitudes choose between various guideline-recommended colorectal cancer screening strategies.

  10. SU-F-T-436: A Method to Evaluate Dosimetric Properties of SFGRT in Eclipse TPS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, M; Tobias, R; Pankuch, M

    Purpose: The objective was to develop a method for dose distribution calculation of spatially-fractionated-GRID-radiotherapy (SFGRT) in Eclipse treatment-planning-system (TPS). Methods: Patient treatment-plans with SFGRT for bulky tumors were generated in Varian Eclipse version11. A virtual structure based on the GRID pattern was created and registered to a patient CT image dataset. The virtual GRID structure was positioned on the iso-center level together with matching beam geometries to simulate a commercially available GRID block made of brass. This method overcame the difficulty in treatment-planning and dose-calculation due to the lack o-the option to insert a GRID block add-on in Eclipse TPS.more » The patient treatment-planning displayed GRID effects on the target, critical structures, and dose distribution. The dose calculations were compared to the measurement results in phantom. Results: The GRID block structure was created to follow the beam divergence to the patient CT images. The inserted virtual GRID block made it possible to calculate the dose distributions and profiles at various depths in Eclipse. The virtual GRID block was added as an option to TPS. The 3D representation of the isodose distribution of the spatially-fractionated beam was generated in axial, coronal, and sagittal planes. Physics of GRID can be different from that for fields shaped by regular blocks because the charge-particle-equilibrium cannot be guaranteed for small field openings. Output factor (OF) measurement was required to calculate the MU to deliver the prescribed dose. The calculated OF based on the virtual GRID agreed well with the measured OF in phantom. Conclusion: The method to create the virtual GRID block has been proposed for the first time in Eclipse TPS. The dosedistributions, in-plane and cross-plane profiles in PTV can be displayed in 3D-space. The calculated OF’s based on the virtual GRID model compare well to the measured OF’s for SFGRT clinical use.« less

  11. Integrated bronchoscopic video tracking and 3D CT registration for virtual bronchoscopy

    NASA Astrophysics Data System (ADS)

    Higgins, William E.; Helferty, James P.; Padfield, Dirk R.

    2003-05-01

    Lung cancer assessment involves an initial evaluation of 3D CT image data followed by interventional bronchoscopy. The physician, with only a mental image inferred from the 3D CT data, must guide the bronchoscope through the bronchial tree to sites of interest. Unfortunately, this procedure depends heavily on the physician's ability to mentally reconstruct the 3D position of the bronchoscope within the airways. In order to assist physicians in performing biopsies of interest, we have developed a method that integrates live bronchoscopic video tracking and 3D CT registration. The proposed method is integrated into a system we have been devising for virtual-bronchoscopic analysis and guidance for lung-cancer assessment. Previously, the system relied on a method that only used registration of the live bronchoscopic video to corresponding virtual endoluminal views derived from the 3D CT data. This procedure only performs the registration at manually selected sites; it does not draw upon the motion information inherent in the bronchoscopic video. Further, the registration procedure is slow. The proposed method has the following advantages: (1) it tracks the 3D motion of the bronchoscope using the bronchoscopic video; (2) it uses the tracked 3D trajectory of the bronchoscope to assist in locating sites in the 3D CT "virtual world" to perform the registration. In addition, the method incorporates techniques to: (1) detect and exclude corrupted video frames (to help make the video tracking more robust); (2) accelerate the computation of the many 3D virtual endoluminal renderings (thus, speeding up the registration process). We have tested the integrated tracking-registration method on a human airway-tree phantom and on real human data.

  12. Reanimating patients: cardio-respiratory CT and MR motion phantoms based on clinical CT patient data

    NASA Astrophysics Data System (ADS)

    Mayer, Johannes; Sauppe, Sebastian; Rank, Christopher M.; Sawall, Stefan; Kachelrieß, Marc

    2017-03-01

    Until today several algorithms have been developed that reduce or avoid artifacts caused by cardiac and respiratory motion in computed tomography (CT). The motion information is converted into so-called motion vector fields (MVFs) and used for motion compensation (MoCo) during the image reconstruction. To analyze these algorithms quantitatively there is the need for ground truth patient data displaying realistic motion. We developed a method to generate a digital ground truth displaying realistic cardiac and respiratory motion that can be used as a tool to assess MoCo algorithms. By the use of available MoCo methods we measured the motion in CT scans with high spatial and temporal resolution and transferred the motion information onto patient data with different anatomy or imaging modality, thereby reanimating the patient virtually. In addition to these images the ground truth motion information in the form of MVFs is available and can be used to benchmark the MVF estimation of MoCo algorithms. We here applied the method to generate 20 CT volumes displaying detailed cardiac motion that can be used for cone-beam CT (CBCT) simulations and a set of 8 MR volumes displaying respiratory motion. Our method is able to reanimate patient data virtually. In combination with the MVFs it serves as a digital ground truth and provides an improved framework to assess MoCo algorithms.

  13. The geometrical precision of virtual bone models derived from clinical computed tomography data for forensic anthropology.

    PubMed

    Colman, Kerri L; Dobbe, Johannes G G; Stull, Kyra E; Ruijter, Jan M; Oostra, Roelof-Jan; van Rijn, Rick R; van der Merwe, Alie E; de Boer, Hans H; Streekstra, Geert J

    2017-07-01

    Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical computed tomography (CT) scans provides a potential solution. However, clinical CT scans are typically generated with varying settings. This study investigates the effects of image segmentation and varying imaging conditions on the precision of virtual modelled pelves. An adult human cadaver was scanned using varying imaging conditions, such as scanner type and standard patient scanning protocol, slice thickness and exposure level. The pelvis was segmented from the various CT images resulting in virtually modelled pelves. The precision of the virtual modelling was determined per polygon mesh point. The fraction of mesh points resulting in point-to-point distance variations of 2 mm or less (95% confidence interval (CI)) was reported. Colour mapping was used to visualise modelling variability. At almost all (>97%) locations across the pelvis, the point-to-point distance variation is less than 2 mm (CI = 95%). In >91% of the locations, the point-to-point distance variation was less than 1 mm (CI = 95%). This indicates that the geometric variability of the virtual pelvis as a result of segmentation and imaging conditions rarely exceeds the generally accepted linear error of 2 mm. Colour mapping shows that areas with large variability are predominantly joint surfaces. Therefore, results indicate that segmented bone elements from patient-derived CT scans are a sufficiently precise source for creating a virtual skeletal database.

  14. Efficacy of a Telehealth Intervention on Colonoscopy Uptake When Cost Is a Barrier: The Family CARE Cluster Randomized Controlled Trial.

    PubMed

    Steffen, Laurie E; Boucher, Kenneth M; Damron, Barbara H; Pappas, Lisa M; Walters, Scott T; Flores, Kristina G; Boonyasiriwat, Watcharaporn; Vernon, Sally W; Stroup, Antoinette M; Schwartz, Marc D; Edwards, Sandra L; Kohlmann, Wendy K; Lowery, Jan T; Wiggins, Charles L; Hill, Deirdre A; Higginbotham, John C; Burt, Randall; Simmons, Rebecca G; Kinney, Anita Y

    2015-09-01

    We tested the efficacy of a remote tailored intervention Tele-Cancer Risk Assessment and Evaluation (TeleCARE) compared with a mailed educational brochure for improving colonoscopy uptake among at-risk relatives of colorectal cancer patients and examined subgroup differences based on participant reported cost barriers. Family members of colorectal cancer patients who were not up-to-date with colonoscopy were randomly assigned as family units to TeleCARE (N = 232) or an educational brochure (N = 249). At the 9-month follow-up, a cost resource letter listing resources for free or reduced-cost colonoscopy was mailed to participants who had reported cost barriers and remained nonadherent. Rates of medically verified colonoscopy at the 15-month follow-up were compared on the basis of group assignment and within group stratification by cost barriers. In intent-to-treat analysis, 42.7% of participants in TeleCARE and 24.1% of participants in the educational brochure group had a medically verified colonoscopy [OR, 2.37; 95% confidence interval (CI) 1.59-3.52]. Cost was identified as a barrier in both groups (TeleCARE = 62.5%; educational brochure = 57.0%). When cost was not a barrier, the TeleCARE group was almost four times as likely as the comparison to have a colonoscopy (OR, 3.66; 95% CI, 1.85-7.24). The intervention was efficacious among those who reported cost barriers; the TeleCARE group was nearly twice as likely to have a colonoscopy (OR, 1.99; 95% CI, 1.12-3.52). TeleCARE increased colonoscopy regardless of cost barriers. Remote interventions may bolster screening colonoscopy regardless of cost barriers and be more efficacious when cost barriers are absent. ©2015 American Association for Cancer Research.

  15. Computer-assisted virtual autopsy using surgical navigation techniques.

    PubMed

    Ebert, Lars Christian; Ruder, Thomas D; Martinez, Rosa Maria; Flach, Patricia M; Schweitzer, Wolf; Thali, Michael J; Ampanozi, Garyfalia

    2015-01-01

    OBJECTIVE; Virtual autopsy methods, such as postmortem CT and MRI, are increasingly being used in forensic medicine. Forensic investigators with little to no training in diagnostic radiology and medical laypeople such as state's attorneys often find it difficult to understand the anatomic orientation of axial postmortem CT images. We present a computer-assisted system that permits postmortem CT datasets to be quickly and intuitively resliced in real time at the body to narrow the gap between radiologic imaging and autopsy. Our system is a potentially valuable tool for planning autopsies, showing findings to medical laypeople, and teaching CT anatomy, thus further closing the gap between radiology and forensic pathology.

  16. Colometer: a real-time quality feedback system for screening colonoscopy.

    PubMed

    Filip, Dobromir; Gao, Xuexin; Angulo-Rodríguez, Leticia; Mintchev, Martin P; Devlin, Shane M; Rostom, Alaa; Rosen, Wayne; Andrews, Christopher N

    2012-08-28

    To investigate the performance of a new software-based colonoscopy quality assessment system. The software-based system employs a novel image processing algorithm which detects the levels of image clarity, withdrawal velocity, and level of the bowel preparation in a real-time fashion from live video signal. Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists. Subsequently, an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization (scored 1-5; 1, when the percentage was 1%-20%; 2, when the percentage was 21%-40%, etc.). In order to test the proposed velocity and blurriness thresholds, screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected, automatically processed and rated. Quality ratings on the withdrawal were compared to the insertion in the same patients. Then, 3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal (scored 1-5; 1, poor; 3, average; 5, excellent) based on 3 major aspects: image quality, colon preparation, and withdrawal velocity. The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient. Fourteen screening colonoscopies were assessed. Adenomatous polyps were detected in 4/14 (29%) of the collected colonoscopy video samples. As a proof of concept, the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps (average percent time with adequate visualization: 79% ± 5% for withdrawal and 50% ± 14% for insertion, P < 0.01). Withdrawal times during which no polyps were removed ranged from 4-12 min. The median quality rating from the automated system and the reviewers was 3.45 [interquartile range (IQR), 3.1-3.68] and 3.00 (IQR, 2.33-3.67) respectively for all colonoscopy video samples. The automated rating revealed a strong correlation with the reviewer's rating (ρ coefficient= 0.65, P = 0.01). There was good correlation of the automated overall quality rating and the mean endoscopist withdrawal speed rating (Spearman r coefficient= 0.59, P = 0.03). There was no correlation of automated overall quality rating with mean endoscopists image quality rating (Spearman r coefficient= 0.41, P = 0.15). The results from a novel automated real-time colonoscopy quality feedback system strongly agreed with the endoscopists' quality assessments. Further study is required to validate this approach.

  17. Matching colonoscopy and pathology data in population-based registries: development of a novel algorithm and the initial experience of the New Hampshire Colonoscopy Registry.

    PubMed

    Greene, Mary Ann; Butterly, Lynn F; Goodrich, Martha; Onega, Tracy; Baron, John A; Lieberman, David A; Dietrich, Allen J; Srivastava, Amitabh

    2011-08-01

    The quality of polyp-level data in a population-based registry depends on the ability to match each polypectomy recorded by the endoscopist to a specific diagnosis on the pathology report. To review impediments encountered in matching colonoscopy and pathology data in a population-based registry. New Hampshire Colonoscopy Registry data from August 2006 to November 2008 were analyzed for prevalence of missing reports, discrepancies between colonoscopy and pathology reports, and the proportion of polyps that could not be matched because of multiple polyps submitted in the same container. New Hampshire Colonoscopy Registry. This study involved all consenting patients during the study period. Develop an algorithm for capturing number, size, location, and histology of polyps and for defining and flagging discrepancies to ensure data quality. The proportion of polyps with no assumption or discrepancy, the proportion of patient records eligible for determining the adenoma detection rate (ADR), and the number of patients with ≥3 adenomas. Only 50% of polyps removed during this period were perfectly matched, with no assumption or discrepancy. Records from only 69.9% and 29.7% of eligible patients could be used to determine the ADR and the number of patients with ≥3 adenomas, respectively. Rates of missing reports may have been higher in the early phase of establishment of the registry. This study highlights the impediments in collecting polyp-level data in a population-based registry and provides useful parameters for evaluating the quality and accuracy of data obtained from such registries. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  18. Colonoscopy demand and capacity in New Hampshire.

    PubMed

    Butterly, Lynn; Olenec, Christopher; Goodrich, Martha; Carney, Patricia; Dietrich, Allen

    2007-01-01

    Screening for colorectal cancer has been clearly shown to decrease the incidence and mortality from this disease. Accurate information about the demand and capacity for screening, particularly with colonoscopy, is critical in planning screening strategies. National assessments have recently begun; estimates of smaller geographic regions should improve the accuracy of national estimates, as well as inform strategies for individual states. This study evaluates the demand and capacity for colonoscopy in the state of New Hampshire. All endoscopy sites in the state of New Hampshire were contacted to determine their number of endoscopists, monthly colonoscopies, and estimates of the percentage of colonoscopy done for screening. Barriers to increasing current capacity were also assessed. The capacity estimates were compared to demand estimates based on population census figures. Data were collected in 2003 to 2004 and analyzed in 2005 to 2006. One hundred fourteen endoscopists at 36 centers performed 49,352 colonoscopies in 2002, an average of 39 to 43 total monthly colonoscopies per endoscopist. Approximately 60% were estimated to have been done for screening. Estimated demand was approximately twice the available capacity for screening and surveillance. The impact of factors such as compliance, percent screening, and population growth were assessed to inform future screening strategies. In 2002, demand for screening colonoscopy in New Hampshire for patients aged more than 50 years was approximately twice the available capacity. However, if the assessed screening capacity of 2002 were to increase by 20%, combined with a target of 60% population compliance with screening as an initial goal, the demand for colonoscopy in New Hampshire would be met.

  19. Development of the Parkland-UT Southwestern Colonoscopy Reporting System (CoRS) for evidence-based colon cancer surveillance recommendations

    PubMed Central

    Gupta, Samir; Halm, Ethan A; Wright, Shaun; McCallister, Katharine; Bishop, Wendy; Santini, Noel; Mayorga, Christian; Agrawal, Deepak; Moran, Brett; Sanders, Joanne M; Singal, Amit G

    2016-01-01

    Objective Through colonoscopy, polyps can be identified and removed to reduce colorectal cancer incidence and mortality. Appropriate use of surveillance colonoscopy, post polypectomy, is a focus of healthcare reform. Materials and Methods The authors developed and implemented the first electronic medical record–based colonoscopy reporting system (CoRS) that matches endoscopic findings with guideline-consistent surveillance recommendations and generates tailored results and recommendation letters for patients and providers. Results In its first year, CoRS was used in 98.6% of indicated cases. Via a survey, colonoscopists agreed/strongly agreed it is easy to use (83%), provides guideline-based recommendations (89%), improves quality of Spanish letters (94%), they would recommend it for other institutions (78%), and it made their work easier (61%), and led to improved practice (56%). Discussion CoRS’ widespread adoption and acceptance likely resulted from stakeholder engagement throughout the development and implementation process. Conclusion CoRS is well-accepted by clinicians and provides guideline-based recommendations and results communications to patients and providers. PMID:26254481

  20. Variation in diagnostic performance among radiologists at screening CT colonography.

    PubMed

    Pooler, B Dustin; Kim, David H; Hassan, Cesare; Rinaldi, Antonio; Burnside, Elizabeth S; Pickhardt, Perry J

    2013-07-01

    To assess the variation in diagnostic performance among radiologists at screening computed tomographic (CT) colonography. In this HIPAA-compliant, institutional review board-approved study, 6866 asymptomatic adults underwent first-time CT colonographic screening at a single center between January 2005 and November 2011. Results of examinations were interpreted by one of eight board-certified abdominal radiologists (mean number of CT colonographic studies per reader, 858; range, 131-2202). Findings at CT colonography and subsequent colonoscopy were recorded, and key measures of diagnostic performance, including adenoma and advanced neoplasia detection rate, were compared among the radiologists. The overall prevalence of histopathologically confirmed advanced neoplasia was 3.6% and did not differ significantly among radiologists (range, 2.4%-4.4%; P = .067; P = .395 when one outlier was excluded). Overall, 19.5% of polyps detected at CT colonography proved to be advanced neoplasia and did not differ significantly among radiologists (range, 14.4%-23.2%; P = .223). The overall per-polyp endoscopic confirmation rate was 93.5%, ranging from 80.0% to 97.6% among radiologists (P = .585). The overall percentage of nondiagnostic CT colonographic examinations was 0.7% and was consistent among radiologists (range, 0.3%-1.1%; P = .509). Consistent performance for adenoma and advanced neoplasia detection, as well as other clinically relevant end points, were observed among radiologists at CT colonographic screening.

  1. Neighborhood Socioeconomic Status and Use of Colonoscopy in an Insured Population – A Retrospective Cohort Study

    PubMed Central

    Doubeni, Chyke A.; Jambaulikar, Guruprasad D.; Fouayzi, Hassan; Robinson, Scott B.; Gunter, Margaret J.; Field, Terry S.; Roblin, Douglas W.; Fletcher, Robert H.

    2012-01-01

    Background Low-socioeconomic status (SES) is associated with a higher colorectal cancer (CRC) incidence and mortality. Screening with colonoscopy, the most commonly used test in the US, has been shown to reduce the risk of death from CRC. This study examined if, among insured persons receiving care in integrated healthcare delivery systems, differences exist in colonoscopy use according to neighborhood SES. Methods We assembled a retrospective cohort of 100,566 men and women, 50–74 years old, who had been enrolled in one of three US health plans for ≥1 year on January 1, 2000. Subjects were followed until the date of first colonoscopy, date of disenrollment from the health plan, or December 31, 2007, whichever occurred first. We obtained data on colonoscopy use from administrative records. We defined screening colonoscopy as an examination that was not preceded by gastrointestinal conditions in the prior 6-month period. Neighborhood SES was measured using the percentage of households in each subject's census-tract with an income below 1999 federal poverty levels based on 2000 US census data. Analyses, adjusted for demographics and comorbidity index, were performed using Weibull regression models. Results The average age of the cohort was 60 years and 52.7% were female. During 449,738 person-years of follow-up, fewer subjects in the lowest SES quartile (Q1) compared to the highest quartile (Q4) had any colonoscopy (26.7% vs. 37.1%) or a screening colonoscopy (7.6% vs. 13.3%). In regression analyses, compared to Q4, subjects in Q1 were 16% (adjusted HR = 0.84, 95% CI: 0.80–0.88) less likely to undergo any colonoscopy and 30%(adjusted HR = 0.70, CI: 0.65–0.75) less likely to undergo a screening colonoscopy. Conclusion People in lower-SES neighborhoods are less likely to undergo a colonoscopy, even among insured subjects receiving care in integrated healthcare systems. Removing health insurance barriers alone is unlikely to eliminate disparities in colonoscopy use. PMID:22567154

  2. Clinical Application of Dual-Energy Spectral Computed Tomography in Detecting Cholesterol Gallstones From Surrounding Bile.

    PubMed

    Yang, Chuang-Bo; Zhang, Shuang; Jia, Yong-Jun; Duan, Hai-Feng; Ma, Guang-Ming; Zhang, Xi-Rong; Yu, Yong; He, Tai-Ping

    2017-04-01

    This study aimed to investigate the clinical value of spectral computed tomography (CT) in the detection of cholesterol gallstones from surrounding bile. This study was approved by the institutional review board. The unenhanced spectral CT data of 24 patients who had surgically confirmed cholesterol gallstones were analyzed. Lipid concentrations and CT numbers were measured from fat-based material decomposition image and virtual monochromatic image sets (40-140 keV), respectively. The difference in lipid concentration and CT number between cholesterol gallstones and the surrounding bile were statistically analyzed. Receiver operating characteristic analysis was applied to determine the diagnostic accuracy of using lipid concentration to differentiate cholesterol gallstones from bile. Cholesterol gallstones were bright on fat-based material decomposition images yielding a 92% detection rate (22 of 24). The lipid concentrations (552.65 ± 262.36 mg/mL), CT number at 40 keV (-31.57 ± 16.88 HU) and 140 keV (24.30 ± 5.85 HU) for the cholesterol gallstones were significantly different from those of bile (-13.94 ± 105.12 mg/mL, 12.99 ± 9.39 HU and 6.19 ± 4.97 HU, respectively). Using 182.59 mg/mL as the threshold value for lipid concentration, one could obtain sensitivity of 95.5% and specificity of 100% with accuracy of 0.994 for differentiating cholesterol gallstones from bile. Virtual monochromatic spectral CT images at 40 keV and 140 keV provide significant CT number differences between cholesterol gallstones and the surrounding bile. Spectral CT provides an excellent detection rate for cholesterol gallstones. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Validity evidence for the Simulated Colonoscopy Objective Performance Evaluation scoring system.

    PubMed

    Trinca, Kristen D; Cox, Tiffany C; Pearl, Jonathan P; Ritter, E Matthew

    2014-02-01

    Low-cost, objective systems to assess and train endoscopy skills are needed. The aim of this study was to evaluate the ability of Simulated Colonoscopy Objective Performance Evaluation to assess the skills required to perform endoscopy. Thirty-eight subjects were included in this study, all of whom performed 4 tasks. The scoring system measured performance by calculating precision and efficiency. Data analysis assessed the relationship between colonoscopy experience and performance on each task and the overall score. Endoscopic trainees' Simulated Colonoscopy Objective Performance Evaluation scores correlated significantly with total colonoscopy experience (r = .61, P = .003) and experience in the past 12 months (r = .63, P = .002). Significant differences were seen among practicing endoscopists, nonendoscopic surgeons, and trainees (P < .0001). When the 4 tasks were analyzed, each showed significant correlation with colonoscopy experience (scope manipulation, r = .44, P = .044; tool targeting, r = .45, P = .04; loop management, r = .47, P = .032; mucosal inspection, r = .65, P = .001) and significant differences in performance between the endoscopist groups, except for mucosal inspection (scope manipulation, P < .0001; tool targeting, P = .002; loop management, P = .0008; mucosal inspection, P = .27). Simulated Colonoscopy Objective Performance Evaluation objectively assesses the technical skills required to perform endoscopy and shows promise as a platform for proficiency-based skills training. Published by Elsevier Inc.

  4. Asia Pacific consensus recommendations for colorectal cancer screening.

    PubMed

    Sung, J J Y; Lau, J Y W; Young, G P; Sano, Y; Chiu, H M; Byeon, J S; Yeoh, K G; Goh, K L; Sollano, J; Rerknimitr, R; Matsuda, T; Wu, K C; Ng, S; Leung, S Y; Makharia, G; Chong, V H; Ho, K Y; Brooks, D; Lieberman, D A; Chan, F K L

    2008-08-01

    Colorectal cancer (CRC) is rapidly increasing in Asia, but screening guidelines are lacking. Through reviewing the literature and regional data, and using the modified Delphi process, the Asia Pacific Working Group on Colorectal Cancer and international experts launch consensus recommendations aiming to improve the awareness of healthcare providers of the changing epidemiology and screening tests available. The incidence, anatomical distribution and mortality of CRC among Asian populations are not different compared with Western countries. There is a trend of proximal migration of colonic polyps. Flat or depressed lesions are not uncommon. Screening for CRC should be started at the age of 50 years. Male gender, smoking, obesity and family history are risk factors for colorectal neoplasia. Faecal occult blood test (FOBT, guaiac-based and immunochemical tests), flexible sigmoidoscopy and colonoscopy are recommended for CRC screening. Double-contrast barium enema and CT colonography are not preferred. In resource-limited countries, FOBT is the first choice for CRC screening. Polyps 5-9 mm in diameter should be removed endoscopically and, following a negative colonoscopy, a repeat examination should be performed in 10 years. Screening for CRC should be a national health priority in most Asian countries. Studies on barriers to CRC screening, education for the public and engagement of primary care physicians should be undertaken. There is no consensus on whether nurses should be trained to perform endoscopic procedures for screening of colorectal neoplasia.

  5. Application of Virtual Navigation with Multimodality Image Fusion in Foramen Ovale Cannulation.

    PubMed

    Qiu, Xixiong; Liu, Weizong; Zhang, Mingdong; Lin, Hengzhou; Zhou, Shoujun; Lei, Yi; Xia, Jun

    2017-11-01

    Idiopathic trigeminal neuralgia (ITN) can be effectively treated with radiofrequency thermocoagulation. However, this procedure requires cannulation of the foramen ovale, and conventional cannulation methods are associated with high failure rates. Multimodality imaging can improve the accuracy of cannulation because each imaging method can compensate for the drawbacks of the other. We aim to determine the feasibility and accuracy of percutaneous foramen ovale cannulation under the guidance of virtual navigation with multimodality image fusion in a self-designed anatomical model of human cadaveric heads. Five cadaveric head specimens were investigated in this study. Spiral computed tomography (CT) scanning clearly displayed the foramen ovale in all five specimens (10 foramina), which could not be visualized using two-dimensional ultrasound alone. The ultrasound and spiral CT images were fused, and percutaneous cannulation of the foramen ovale was performed under virtual navigation. After this, spiral CT scanning was immediately repeated to confirm the accuracy of the cannulation. Postprocedural spiral CT confirmed that the ultrasound and CT images had been successfully fused for all 10 foramina, which were accurately and successfully cannulated. The success rates of both image fusion and cannulation were 100%. Virtual navigation with multimodality image fusion can substantially facilitate foramen ovale cannulation and is worthy of clinical application. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  6. Performance of today’s dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faby, Sebastian, E-mail: sebastian.faby@dkfz.de; Kuchenbecker, Stefan; Sawall, Stefan

    2015-07-15

    Purpose: To study the performance of different dual energy computed tomography (DECT) techniques, which are available today, and future multi energy CT (MECT) employing novel photon counting detectors in an image-based material decomposition task. Methods: The material decomposition performance of different energy-resolved CT acquisition techniques is assessed and compared in a simulation study of virtual non-contrast imaging and iodine quantification. The material-specific images are obtained via a statistically optimal image-based material decomposition. A projection-based maximum likelihood approach was used for comparison with the authors’ image-based method. The different dedicated dual energy CT techniques are simulated employing realistic noise models andmore » x-ray spectra. The authors compare dual source DECT with fast kV switching DECT and the dual layer sandwich detector DECT approach. Subsequent scanning and a subtraction method are studied as well. Further, the authors benchmark future MECT with novel photon counting detectors in a dedicated DECT application against the performance of today’s DECT using a realistic model. Additionally, possible dual source concepts employing photon counting detectors are studied. Results: The DECT comparison study shows that dual source DECT has the best performance, followed by the fast kV switching technique and the sandwich detector approach. Comparing DECT with future MECT, the authors found noticeable material image quality improvements for an ideal photon counting detector; however, a realistic detector model with multiple energy bins predicts a performance on the level of dual source DECT at 100 kV/Sn 140 kV. Employing photon counting detectors in dual source concepts can improve the performance again above the level of a single realistic photon counting detector and also above the level of dual source DECT. Conclusions: Substantial differences in the performance of today’s DECT approaches were found for the application of virtual non-contrast and iodine imaging. Future MECT with realistic photon counting detectors currently can only perform comparably to dual source DECT at 100 kV/Sn 140 kV. Dual source concepts with photon counting detectors could be a solution to this problem, promising a better performance.« less

  7. Is there a superior simulator for human anatomy education? How virtual dissection can overcome the anatomic and pedagogic limitations of cadaveric dissection.

    PubMed

    Darras, Kathryn E; de Bruin, Anique B H; Nicolaou, Savvas; Dahlström, Nils; Persson, Anders; van Merriënboer, Jeroen; Forster, Bruce B

    2018-03-23

    Educators must select the best tools to teach anatomy to future physicians and traditionally, cadavers have always been considered the "gold standard" simulator for living anatomy. However, new advances in technology and radiology have created new teaching tools, such as virtual dissection, which provide students with new learning opportunities. Virtual dissection is a novel way of studying human anatomy through patient computed tomography (CT) scans. Through touchscreen technology, students can work together in groups to "virtually dissect" the CT scans to better understand complex anatomic relationships. This article presents the anatomic and pedagogic limitations of cadaveric dissection and explains what virtual dissection is and how this new technology may be used to overcome these limitations.

  8. Diagnostic accuracy of translucency rendering to differentiate polyps from pseudopolyps at 3D endoluminal CT colonography: a feasibility study.

    PubMed

    Guerrisi, A; Marin, D; Laghi, A; Di Martino, M; Iafrate, F; Iannaccone, R; Catalano, C; Passariello, R

    2010-08-01

    The aim of this study was to assess the accuracy of translucency rendering (TR) in computed tomographic (CT) colonography without cathartic preparation using primary 3D reading. From 350 patients with 482 endoscopically verified polyps, 50 pathologically proven polyps and 50 pseudopolyps were retrospectively examined. For faecal tagging, all patients ingested 140 ml of orally administered iodinated contrast agent (diatrizoate meglumine and diatrizoate sodium) at meals 48 h prior to CT colonography examination and two h prior to scanning. CT colonography was performed using a 64-section CT scanner. Colonoscopy with segmental unblinding was performed within 2 weeks after CT. Three independent radiologists retrospectively evaluated TRCT clonographic images using a dedicated software package (V3D-Colon System). To enable size-dependent statistical analysis, lesions were stratified into the following size categories: small (< or =5 mm), intermediate (6-9 mm), and large (> or =10 mm). Overall average TR sensitivity for polyp characterisation was 96.6%, and overall average specificity for pseudopolyp characterisation was 91.3%. Overall average diagnostic accuracy (area under the curve) of TR for characterising colonic lesions was 0.97. TR is an accurate tool that facilitates interpretation of images obtained with a primary 3D analysis, thus enabling easy differentiation of polyps from pseudopolyps.

  9. Creation of an idealized nasopharynx geometry for accurate computational fluid dynamics simulations of nasal airflow in patient-specific models lacking the nasopharynx anatomy

    PubMed Central

    Borojeni, Azadeh A.T.; Frank-Ito, Dennis O.; Kimbell, Julia S.; Rhee, John S.; Garcia, Guilherme J. M.

    2016-01-01

    Virtual surgery planning based on computational fluid dynamics (CFD) simulations has the potential to improve surgical outcomes for nasal airway obstruction (NAO) patients, but the benefits of virtual surgery planning must outweigh the risks of radiation exposure. Cone beam computed tomography (CBCT) scans represent an attractive imaging modality for virtual surgery planning due to lower costs and lower radiation exposures compared with conventional CT scans. However, to minimize the radiation exposure, the CBCT sinusitis protocol sometimes images only the nasal cavity, excluding the nasopharynx. The goal of this study was to develop an idealized nasopharynx geometry for accurate representation of outlet boundary conditions when the nasopharynx geometry is unavailable. Anatomically-accurate models of the nasopharynx created from thirty CT scans were intersected with planes rotated at different angles to obtain an average geometry. Cross sections of the idealized nasopharynx were approximated as ellipses with cross-sectional areas and aspect ratios equal to the average in the actual patient-specific models. CFD simulations were performed to investigate whether nasal airflow patterns were affected when the CT-based nasopharynx was replaced by the idealized nasopharynx in 10 NAO patients. Despite the simple form of the idealized geometry, all biophysical variables (nasal resistance, airflow rate, and heat fluxes) were very similar in the idealized vs. patient-specific models. The results confirmed the expectation that the nasopharynx geometry has a minimal effect in the nasal airflow patterns during inspiration. The idealized nasopharynx geometry will be useful in future CFD studies of nasal airflow based on medical images that exclude the nasopharynx. PMID:27525807

  10. Delivering colonoscopy screening for low-income populations in Suffolk County: strategies, outcomes, and benchmarks.

    PubMed

    Lane, Dorothy S; Messina, Catherine R; Cavanagh, Mary F; Anderson, Joseph C

    2013-08-01

    Current and pending legislation provides colorectal cancer screening reimbursement for previously uninsured populations. Colonoscopy is currently the screening method most frequently recommended by physicians for insured patients. The experience of the SCOPE (Suffolk County Preventive Endoscopy) demonstration project (Project SCOPE) at Stony Brook University Medical Center provides a model for delivering colonoscopy screening to low-income populations to meet anticipated increasing demands. Project SCOPE, based in the Department of Preventive Medicine, featured internal collaboration with the academic medical center's large gastroenterology practice and external collaboration with the Suffolk County Department of Health Services' network of community health centers. Colonoscopies were performed by faculty gastroenterologists or supervised fellows. Measures of colonoscopy performance were compared with quality indicators and differences between faculty and supervised fellows were identified. During a 40-month screening period, 800 initial colonoscopies were performed. Approximately 21% of women screened were found to have adenomatous polyps compared with 36% of men. Five cancers were detected. The majority of the population screened (70%) were members of minority populations. African American individuals had a higher percentage of proximally located adenomas (78%) compared with white individuals (65%) and Hispanics (49%), based on the location of the most advanced lesion. Hispanic individuals had a 36% lower risk of adenomas compared with white individuals. Performance measures including the percentage of procedures with adequate bowel preparation, cecum reached, scope withdrawal time, and adenoma detection rate met quality benchmarks when performed by either faculty or supervised fellows. Project SCOPE's operational strategies demonstrated a feasible method for an academic medical center to provide high-quality screening colonoscopy for low-income populations. © 2013 American Cancer Society.

  11. Translation of First North American 50 and 70 cc Total Artificial Heart Virtual and Clinical Implantations: Utility of 3D Computed Tomography to Test Fit Devices.

    PubMed

    Ferng, Alice S; Oliva, Isabel; Jokerst, Clinton; Avery, Ryan; Connell, Alana M; Tran, Phat L; Smith, Richard G; Khalpey, Zain

    2017-08-01

    Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Screening for colorectal cancer with FOBT, virtual colonoscopy and optical colonoscopy: study protocol for a randomized controlled trial in the Florence district (SAVE study)

    PubMed Central

    2013-01-01

    Background Colorectal cancer (CRC) is the most frequent cancer in Europe. Randomized clinical trials demonstrated that screening with fecal occult blood test (FOBT) reduces mortality from CRC. Accordingly, the European Community currently recommends population-based screening with FOBT. Other screening tests, such as computed tomography colonography (CTC) and optical colonoscopy (OC), are highly accurate for examining the entire colon for adenomas and CRC. Acceptability represents a critical determinant of the impact of a screening program. We designed a randomized controlled trial to compare participation rate and diagnostic yield of FOBT, CTC with computer-aided diagnosis, and OC as primary tests for population-based screening. Methods/Design A total of 14,000 subjects aged 55 to 64 years, living in the Florence district and never screened for CRC, will be randomized in three arms: group 1 (5,000 persons) invited to undergo CTC (divided into: subgroup 1A with reduced cathartic preparation and subgroup 1B with standard bowel preparation); group 2 (8,000 persons) invited to undergo a biannual FOBT for three rounds; and group 3 (1,000 persons) invited to undergo OC. Subjects of each group will be invited by mail to undergo the selected test. All subjects with a positive FOBT or CTC test (that is, mass or at least one polyp ≥6 mm) will be invited to undergo a second-level OC. Primary objectives of the study are to compare the participation rate to FOBT, CTC and OC; to compare the detection rate for cancer or advanced adenomas of CTC versus three rounds of biannual FOBT; to evaluate referral rate for OC induced by primary CTC versus three rounds of FOBT; and to estimate costs of the three screening strategies. A secondary objective of the study is to create a biological bank of blood and stool specimens from subjects undergoing CTC and OC. Discussion This study will provide information about participation/acceptability, diagnostic yield and costs of screening with CTC in comparison with the recommended test (FOBT) and OC. Trial registration ClinicalTrials.gov Identifier: NCT01651624. PMID:23497601

  13. Navigation system for robot-assisted intra-articular lower-limb fracture surgery.

    PubMed

    Dagnino, Giulio; Georgilas, Ioannis; Köhler, Paul; Morad, Samir; Atkins, Roger; Dogramadzi, Sanja

    2016-10-01

    In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon's virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of [Formula: see text] (translational) and [Formula: see text] (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and [Formula: see text], when the robot reduced the fracture. Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and [Formula: see text], and meeting the clinical requirements for distal femur fracture reduction procedures.

  14. Human identification based on cranial computed tomography scan — a case report

    PubMed Central

    Silva, RF; Botelho, TL; Prado, FB; Kawagushi, JT; Daruge Júnior, E; Bérzin, F

    2011-01-01

    Today, there is increasing use of CT scanning on a clinical basis, aiding in the diagnosis of diseases or injuries. This exam also provides important information that allows identification of individuals. This paper reports the use of a CT scan on the skull, taken when the victim was alive, for the positive identification of a victim of a traffic accident in which the fingerprint analysis was impossible. The authors emphasize that the CT scan is a tool primarily used in clinical diagnosis and may contribute significantly to forensic purpose, allowing the exploration of virtual corpses before the classic autopsy. The use of CT scans might increase the quantity and quality of information involved in the death of the person examined. PMID:21493883

  15. Colonoscopy-induced acute diverticulitis: myth or reality?

    PubMed

    Gorgun, Emre; Isik, Ozgen; Sapci, Ipek; Aytac, Erman; Abbas, Maher A; Ozuner, Gokhan; Church, James; Steele, Scott R

    2018-07-01

    Colonoscopy in patients with diverticulosis can be technically challenging and limited data exist relating to the risk of post-colonoscopy diverticulitis. Our aim was to evaluate the incidence, management, and outcomes of acute diverticulitis following colonoscopy. Study design is retrospective cohort study. Data were gathered by conducting an automated search of the electronic patient database using current procedural terminology and ICD-9 codes. Patients who underwent a colonoscopy from 2003 to 2012 were reviewed to find patients who developed acute diverticulitis within 30 days after colonoscopy. Patient demographics and colonoscopy-related outcomes were documented, which include interval between colonoscopy and diverticulitis, colonoscopy indication, simultaneous colonoscopic interventions, and follow-up after colonoscopy. From 236,377 colonoscopies performed during the study period, 68 patients (mean age 56 years) developed post-colonoscopy diverticulitis (0.029%; 2.9 per 10,000 colonoscopies). Incomplete colonoscopies were more frequent among patients with a history of previous diverticulitis [n = 10 (29%) vs. n = 3 (9%), p = 0.03]. Mean time to develop diverticulitis after colonoscopy was 12 ± 8 days, and 30 (44%) patients required hospitalization. 34 (50%) patients had a history of diverticulitis prior to colonoscopy. Among those patients, 14 underwent colonoscopy with an indication of surveillance for previous disease. When colonoscopy was performed within 6 weeks of a diverticulitis attack, surgical intervention was required more often when compared with colonoscopies performed after 6 weeks of an acute attack [n = 6 (100%) vs. n = 10 (36%), p = 0.006]. 6 (9%) out of 68 patients received emergency surgical treatment. 15 (24%) out of 62 patients who had non-surgical treatment initially underwent an elective sigmoidectomy at a later date. Recurrent diverticulitis developed in 16 (23%) patients after post-colonoscopy diverticulitis. Post-colonoscopy diverticulitis is a rare, but potentially serious complication. Although a rare entity, possibility of this complication should be kept in mind in patients presenting with symptoms after colonoscopy.

  16. SU-F-303-12: Implementation of MR-Only Simulation for Brain Cancer: A Virtual Clinical Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glide-Hurst, C; Zheng, W; Kim, J

    2015-06-15

    Purpose: To perform a retrospective virtual clinical trial using an MR-only workflow for a variety of brain cancer cases by incorporating novel imaging sequences, tissue segmentation using phase images, and an innovative synthetic CT (synCT) solution. Methods: Ten patients (16 lesions) were evaluated using a 1.0T MR-SIM including UTE-DIXON imaging (TE = 0.144/3.4/6.9ms). Bone-enhanced images were generated from DIXON-water/fat and inverted UTE. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating intersection and Dice similarity coefficients (DSC) using CT-SIM as ground truth. SynCTs were generated using voxel-based weighted summation incorporating T2, FLAIR, UTE1,more » and bone-enhanced images. Mean absolute error (MAE) characterized HU differences between synCT and CT-SIM. Dose was recalculated on synCTs; differences were quantified using planar gamma analysis (2%/2 mm dose difference/distance to agreement) at isocenter. Digitally reconstructed radiographs (DRRs) were compared. Results: On average, air maps intersected 80.8 ±5.5% (range: 71.8–88.8%) between MR-SIM and CT-SIM yielding DSCs of 0.78 ± 0.04 (range: 0.70–0.83). Whole-brain MAE between synCT and CT-SIM was 160.7±8.8 HU, with the largest uncertainty arising from bone (MAE = 423.3±33.2 HU). Gamma analysis revealed pass rates of 99.4 ± 0.04% between synCT and CT-SIM for the cohort. Dose volume histogram analysis revealed that synCT tended to yield slightly higher doses. Organs at risk such as the chiasm and optic nerves were most sensitive due to their proximities to air/bone interfaces. DRRs generated via synCT and CT-SIM were within clinical tolerances. Conclusion: Our approach for MR-only simulation for brain cancer treatment planning yielded clinically acceptable results relative to the CT-based benchmark. While slight dose differences were observed, reoptimization of treatment plans and improved image registration can address this limitation. Future work will incorporate automated registration between setup images (cone-beam CT and kilovoltage images) for synCT and CT-SIM. Submitting institution holds research agreements with Philips HealthCare, Best, Netherlands and Varian Medical Systems, Palo Alto, CA. Research partially sponsored via an Internal Mentored Research Grant.« less

  17. Prospective study of device-related complications in intensive care unit detected by virtual autopsy.

    PubMed

    Wichmann, D; Heinemann, A; Zähler, S; Vogel, H; Höpker, W; Püschel, K; Kluge, S

    2018-06-01

    There has been increasing use of invasive techniques, such as extracorporeal organ support, in intensive care units (ICU), and declining autopsy rates. Thus, new measures are needed to maintain high-quality standards. We investigated the potential of computed tomography (CT)-based virtual autopsy to substitute for medical autopsy in this setting. We investigated the potential of virtual autopsy by post-mortem CT to identify complications associated with medical devices in a prospective study of patients who had died in the ICU. Clinical records were reviewed to determine the number and types of medical devices used, and findings from medical and virtual autopsies, related and unrelated to the medical devices, were compared. Medical and virtual autopsies could be performed in 61 patients (Group M/V), and virtual autopsy only in 101 patients (Group V). In Group M/V, 41 device-related complications and 30 device malpositions were identified, but only with a low inter-method agreement. Major findings unrelated to a device were identified in about 25% of patients with a high level of agreement between methods. In Group V, 8 device complications and 36 device malpositions were identified. Device-related complications are frequent in ICU patients. Virtual and medical autopsies showed clear differences in the detection of complications and device malpositions. Both methods should supplement each other rather than one alone for quality control of medical devices in the ICU. Further studies should focus on the identification of special patient populations in which virtual autopsy might be of particular benefit. NCT01541982. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  18. The Development of Second Language Critical Thinking in a Virtual Language Learning Environment: A Process-Oriented Mixed-Method Study

    ERIC Educational Resources Information Center

    Mroz, Aurore

    2015-01-01

    This article presents a process-oriented mixed-method study, focusing on the emergence of second language (L2) critical thinking (CT) skills in the collaborative discourse produced by a focal group of five college-level students of French working in a virtual language learning environment (the VLLE Cinet Second Life). Levels of CT ability were…

  19. Elimination of waste: creation of a successful Lean colonoscopy program at an academic medical center.

    PubMed

    Damle, Aneel; Andrew, Nathan; Kaur, Shubjeet; Orquiola, Alan; Alavi, Karim; Steele, Scott R; Maykel, Justin

    2016-07-01

    Lean processes involve streamlining methods and maximizing efficiency. Well established in the manufacturing industry, they are increasingly being applied to health care. The objective of this study was to determine feasibility and effectiveness of applying Lean principles to an academic medical center colonoscopy unit. Lean process improvement involved training endoscopy personnel, observing patients, mapping the value stream, analyzing patient flow, designing and implementing new processes, and finally re-observing the process. Our primary endpoint was total colonoscopy time (minutes from check-in to discharge) with secondary endpoints of individual segment times and unit colonoscopy capacity. A total of 217 patients were included (November 2013-May 2014), with 107 pre-Lean and 110 post-Lean intervention. Pre-Lean total colonoscopy time was 134 min. After implementation of the Lean process, mean colonoscopy time decreased by 10 % to 121 min (p = 0.01). The three steps of the process affected by the Lean intervention (time to achieve adequate sedation, time to recovery, and time to discharge) decreased from 3.7 to 2.4 min (p < 0.01), 4.0 to 3.4 min (p = 0.09), and 41.2 to 35.4 min (p = 0.05), respectively. Overall, unit capacity of colonoscopies increased from 39.6 per day to 43.6. Post-Lean patient satisfaction surveys demonstrated an average score of 4.5/5.0 (n = 73) regarding waiting time, 4.9/5.0 (n = 60) regarding how favorably this experienced compared to prior colonoscopy experiences, and 4.9/5.0 (n = 74) regarding professionalism of staff. One hundred percentage of respondents (n = 69) stated they would recommend our institution to a friend for colonoscopy. With no additional utilization of resources, a single Lean process improvement cycle increased productivity and capacity of our colonoscopy unit. We expect this to result in increased patient access and revenue while maintaining patient satisfaction. We believe these results are widely generalizable to other colonoscopy units as well as other process-based interventions in health care.

  20. [Study on the effect of vertebrae semi-dislocation on the stress distribution in facet joint and interuertebral disc of patients with cervical syndrome based on the three dimensional finite element model].

    PubMed

    Zhang, Ming-cai; Lü, Si-zhe; Cheng, Ying-wu; Gu, Li-xu; Zhan, Hong-sheng; Shi, Yin-yu; Wang, Xiang; Huang, Shi-rong

    2011-02-01

    To study the effect of vertebrae semi-dislocation on the stress distribution in facet joint and interuertebral disc of patients with cervical syndrome using three dimensional finite element model. A patient with cervical spondylosis was randomly chosen, who was male, 28 years old, and diagnosed as cervical vertebra semidislocation by dynamic and static palpation and X-ray, and scanned from C(1) to C(7) by 0.75 mm slice thickness of CT. Based on the CT data, the software was used to construct the three dimensional finite element model of cervical vertebra semidislocation (C(4)-C(6)). Based on the model,virtual manipulation was used to correct the vertebra semidislocation by the software, and the stress distribution was analyzed. The result of finite element analysis showed that the stress distribution of C(5-6) facet joint and intervertebral disc changed after virtual manipulation. The vertebra semidislocation leads to the abnormal stress distribution of facet joint and intervertebral disc.

  1. Serious complications within 30 days of screening and surveillance colonoscopy are uncommon

    PubMed Central

    Ko, Cynthia W.; Riffle, Stacy; Michaels, LeAnn; Morris, Cynthia; Holub, Jennifer; Shapiro, Jean A.; Ciol, Marcia A.; Kimmey, Michael B.; Seeff, Laura C.; Lieberman, David

    2009-01-01

    Background & Aims The risk of serious complications after colonoscopy has important implications for the overall benefits of colorectal cancer screening programs. We evaluated the incidence of serious complications within 30 days after screening or surveillance colonoscopies in diverse clinical settings and to identify potential risk factors for complications. Methods Patients age 40 and over undergoing colonoscopy for screening, surveillance, or evaluation based an abnormal result from another screening test were enrolled through the National Endoscopic Database (CORI). Patients completed a standardized telephone interview approximately 7 and 30 days after their colonoscopy. We estimated the incidence of serious complications within 30 days of colonoscopy and identified risk factors associated with complications using logistic regression analyses. Results 21,375 patients were enrolled. Gastrointestinal bleeding requiring hospitalization occurred in 34 patients (incidence 1.59/1000 exams; 95% confidence interval [CI] 1.10–2.22). Perforations occurred in 4 patients (0.19/1000 exams; 95% CI 0.05–0.48), diverticulitis requiring hospitalization in 5 patients (0.23/1000 exams; 95% CI 0.08–0.54), and post-polypectomy syndrome in 2 patients (0.09/1000 exams; 95%CI 0.02–0.30). The overall incidence of complications directly related to colonoscopy was 2.01 per 1000 exams (95%CI 1.46–2.71). Two of the four perforations occurred without biopsy or polypectomy. The risk of complications increased with pre-procedure warfarin use and performance of polypectomy with cautery. Conclusions Complications after screening or surveillance colonoscopy are uncommon. Risk factors for complications include warfarin use and polypectomy with cautery. PMID:19850154

  2. The Effect of Right Colon Retroflexion on Adenoma Detection: A Systematic Review and Meta-analysis.

    PubMed

    Cohen, Jonah; Grunwald, Douglas; Grossberg, Laurie B; Sawhney, Mandeep S

    2017-10-01

    Although colonoscopy with polypectomy can prevent up to 80% of colorectal cancers, a significant adenoma miss rate still exists, particularly in the right colon. Previous studies addressing right colon retroflexion have revealed discordant evidence regarding the benefit of this maneuver on adenoma detection with concomitant concerns about safety and rates of maneuver success. In this meta-analysis, we sought to determine the effect of right colon retroflexion on improving adenoma detection compared with conventional colonoscopy without retroflexion, as well as determine the rates of retroflexion maneuver success and adverse events. Multiple databases including MEDLINE, Embase, and Web of Science were searched for studies on right colon retroflexion and its impact on adenoma detection compared with conventional colonoscopy. Pooled analyses of adenoma detection and retroflexion success were based on mixed-effects and random-effects models with heterogeneity analyses. Eight studies met the inclusion criteria (N=3660). The primary analysis comparing colonoscopy with right-sided retroflexion versus conventional colonoscopy to determine the per-adenoma miss rate in the right colon was 16.9% (95% confidence interval, 12.5%-22.5%). The overall rate of successful retroflexion was 91.9% (95% confidence interval, 86%-95%) and rate of adverse events was 0.03%. Colonoscopy with right-sided retroflexion significantly increases the detection of adenomas in the right colon compared with conventional colonoscopy with a high rate of maneuver success and small risk of adverse events. Thus, reexamination of the right colon in retroflexed view should be strongly considered in future standard of care colonoscopy guidelines for quality improvement in colon cancer prevention.

  3. Integration of stereotactic ultrasonic data into an interactive image-guided neurosurgical system

    NASA Astrophysics Data System (ADS)

    Shima, Daniel W.; Galloway, Robert L., Jr.

    1998-06-01

    Stereotactic ultrasound can be incorporated into an interactive, image-guide neurosurgical system by using an optical position sensor to define the location of an intraoperative scanner in physical space. A C-program has been developed that communicates with the OptotrakTM system developed by Northern Digital Inc. to optically track the three-dimensional position and orientation of a fan-shaped area defined with respect to a hand-held probe. (i.e., a virtual B-mode ultrasound fan beam) Volumes of CT and MR head scans from the same patient are registered to a location in physical space using a point-based technique. The coordinates of the virtual fan beam in physical space are continuously calculated and updated on-the-fly. During each program loop, the CT and MR data volumes are reformatted along the same plane and displayed as two fan-shaped images that correspond to the current physical-space location of the virtual fan beam. When the reformatted preoperative tomographic images are eventually paired with a real-time intraoperative ultrasound image, a neurosurgeon will be able to use the unique information of each imaging modality (e.g., the high resolution and tissue contrast of CT and MR and the real-time functionality of ultrasound) in a complementary manner to identify structures in the brain more easily and to guide surgical procedures more effectively.

  4. Value of C-Arm Cone Beam Computed Tomography Image Fusion in Maximizing the Versatility of Endovascular Robotics.

    PubMed

    Chinnadurai, Ponraj; Duran, Cassidy; Al-Jabbari, Odeaa; Abu Saleh, Walid K; Lumsden, Alan; Bismuth, Jean

    2016-01-01

    To report our initial experience and highlight the value of using intraoperative C-arm cone beam computed tomography (CT; DynaCT(®)) image fusion guidance along with steerable robotic endovascular catheter navigation to optimize vessel cannulation. Between May 2013 and January 2015, all patients who underwent endovascular procedures using DynaCT image fusion technique along with Hansen Magellan vascular robotic catheter were included in this study. As a part of preoperative planning, relevant vessel landmarks were electronically marked in contrast-enhanced multi-slice computed tomography images and stored. At the beginning of procedure, an intraoperative noncontrast C-arm cone beam CT (syngo DynaCT(®), Siemens Medical Solutions USA Inc.) was acquired in the hybrid suite. Preoperative images were then coregistered to intraoperative DynaCT images using aortic wall calcifications and bone landmarks. Stored landmarks were then overlaid on 2-dimensional (2D) live fluoroscopic images as virtual markers that are updated in real-time with C-arm, table movements and image zoom. Vascular access and robotic catheter (Magellan(®), Hansen Medical) was setup per standard. Vessel cannulation was performed based on electronic virtual markers on live fluoroscopy using robotic catheter. The impact of 3-dimensional (3D) image fusion guidance on robotic vessel cannulation was evaluated retrospectively, by assessing quantitative parameters like number of angiograms acquired before vessel cannulation and qualitative parameters like accuracy of vessel ostium and centerline markers. All 17 vessels were cannulated successfully in 14 patients' attempted using robotic catheter and image fusion guidance. Median vessel diameter at origin was 5.4 mm (range, 2.3-13 mm), whereas 12 of 17 (70.6%) vessels had either calcified and/or stenosed origin from parent vessel. Nine of 17 vessels (52.9 %) were cannulated without any contrast injection. Median number of angiograms required before cannulation was 0 (range, 0-2). On qualitative assessment, 14 of 15 vessels (93.3%) had grade = 1 accuracy (guidewire inside virtual ostial marker). Fourteen of 14 vessels had grade = 1 accuracy (virtual centerlines that matched with the actual vessel trajectory during cannulation). In this small series, the experience of using DynaCT image fusion guidance together with a steerable endovascular robotic catheter indicates that such image fusion strategies can enhance intraoperative 2D fluoroscopy by bringing preoperative 3D information about vascular stenosis and/or calcification, angulation, and take off from main vessel thereby facilitating ultimate vessel cannulation. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Comparative Effectiveness of Fecal Immunochemical Test Outreach, Colonoscopy Outreach, and Usual Care for Boosting Colorectal Cancer Screening Among the Underserved

    PubMed Central

    Gupta, Samir; Halm, Ethan A.; Rockey, Don C.; Hammons, Marcia; Koch, Mark; Carter, Elizabeth; Valdez, Luisa; Tong, Liyue; Ahn, Chul; Kashner, Michael; Argenbright, Keith; Tiro, Jasmin; Geng, Zhuo; Pruitt, Sandi; Skinner, Celette Sugg

    2017-01-01

    IMPORTANCE Colorectal cancer (CRC) screening saves lives, but participation rates are low among underserved populations. Knowledge on effective approaches for screening the underserved, including best test type to offer, is limited. OBJECTIVE To determine (1) if organized mailed outreach boosts CRC screening compared with usual care and (2) if FIT is superior to colonoscopy outreach for CRC screening participation in an underserved population. DESIGN, SETTING, AND PARTICIPANTS We identified uninsured patients, not up to date with CRC screening, age 54 to 64 years, served by the John Peter Smith Health Network, Fort Worth and Tarrant County, Texas, a safety net health system. INTERVENTIONS Patients were assigned randomly to 1 of 3 groups. One group was assigned to fecal immunochemical test (FIT) outreach, consisting of mailed invitation to use and return an enclosed no-cost FIT (n = 1593). A second was assigned to colonoscopy outreach, consisting of mailed invitation to schedule a no-cost colonoscopy (n = 479). The third group was assigned to usual care, consisting of opportunistic primary care visit-based screening (n = 3898). In addition, FIT and colonoscopy outreach groups received telephone follow-up to promote test completion. MAIN OUTCOME MEASURES Screening participation in any CRC test within 1 year after randomization. RESULTS Mean patient age was 59 years; 64% of patients were women. The sample was 41% white, 24% black, 29% Hispanic, and 7% other race/ethnicity. Screening participation was significantly higher for both FIT (40.7%) and colonoscopy outreach (24.6%) than for usual care (12.1%) (P < .001 for both comparisons with usual care). Screening was significantly higher for FIT than for colonoscopy outreach (P < .001). In stratified analyses, screening was higher for FIT and colonoscopy outreach than for usual care, and higher for FIT than for colonoscopy outreach among whites, blacks, and Hispanics (P < .005 for all comparisons). Rates of CRC identification and advanced adenoma detection were 0.4% and 0.8% for FIT outreach, 0.4% and 1.3% for colonoscopy outreach, and 0.2% and 0.4% for usual care, respectively (P < .05 for colonoscopy vs usual care advanced adenoma comparison; P > .05 for all other comparisons). Eleven of 60 patients with abnormal FIT results did not complete colonoscopy. CONCLUSIONS AND REVELANCE Among underserved patients whose CRC screening was not up to date, mailed outreach invitations resulted in markedly higher CRC screening compared with usual care. Outreach was more effective with FIT than with colonoscopy invitation. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01191411 PMID:23921906

  6. Factors affecting compliance with colorectal cancer screening among households residing in the largely Haitian community of Little Haiti, Miami-Dade County, Florida: an observational study.

    PubMed

    Wilcox, Meredith Leigh; Acuña, Juan Manuel; de la Vega, Pura Rodriguez; Castro, Grettel; Madhivanan, Purnima

    2015-05-01

    The United States Black population is disproportionately affected by colorectal cancer (CRC) in terms of incidence and mortality. Studies suggest that screening rates are lower among Blacks compared with non-Hispanic Whites (NHWs). However, studies on CRC screening within Black subgroups are lacking. This study examined disparities in blood stool test (BST) compliance and colonoscopy use by race/ethnicity (Haitian, NHW, non-Hispanic Black [NHB], and Hispanic) among randomly selected households in Little Haiti, Miami-Dade County, Florida.This study used cross-sectional, health and wellness data from a random-sample, population-based survey conducted within 951 households in Little Haiti between November 2011 and December 2012. BST compliance and colonoscopy use were self-reported and defined, conservatively, as the use of BST within the past 2 years and the ever use of colonoscopy by any household member. Factors associated with BST compliance and colonoscopy use were identified using logistic regression models. Analyses were restricted to households containing at least 1 member ≥50 years (n = 666).Nearly half of the households were compliant with BST (rate [95% confidence interval (CI)] = 45% [41%-49%]) and completed colonoscopy (rate [95% CI] = 53% [49%-58%]). Compliance with BST was not associated with race/ethnicity (P = 0.76). Factors independently associated with BST compliance included low educational attainment (adjusted odds ratio [AOR] = 0.63, P = 0.03), being single (AOR = 0.47, P = 0.004), retirement (AOR = 1.96, P = 0.01), and the presence of diagnosed health problems (AOR = 1.24, P = 0.01). Colonoscopy use was lower among Haitian households (46%) compared with NHW (63%), NHB (62%), and Hispanic households (54%) (P = 0.002). Factors independently associated with colonoscopy use included identifying as NHB (compared with Haitian) (AOR = 1.80, P = 0.05), being single (AOR = 0.44, P = 0.001), retirement (AOR = 1.86, P = 0.02), lack of continuous insurance (AOR = 0.45, P < 0.001), and the presence of diagnosed health problems (AOR = 1.44, P < 0.001) and physical limitations/disabilities (AOR = 1.88, P = 0.05).Compliance with BST and use of colonoscopy are low within households in the Little Haiti community. Significant disparities in the use of colonoscopy exist between Haitian and NHB households. Barriers and facilitators of colonoscopy within each racial/ethnic group need to be identified as the next step to developing culturally appropriate, community-based interventions aimed at increasing colonoscopy use in this large minority population.

  7. Variation in Diagnostic Performance among Radiologists at Screening CT Colonography

    PubMed Central

    Pooler, B. Dustin; Kim, David H.; Hassan, Cesare; Rinaldi, Antonio; Burnside, Elizabeth S.

    2013-01-01

    Purpose: To assess the variation in diagnostic performance among radiologists at screening computed tomographic (CT) colonography. Materials and Methods: In this HIPAA-compliant, institutional review board–approved study, 6866 asymptomatic adults underwent first-time CT colonographic screening at a single center between January 2005 and November 2011. Results of examinations were interpreted by one of eight board-certified abdominal radiologists (mean number of CT colonographic studies per reader, 858; range, 131–2202). Findings at CT colonography and subsequent colonoscopy were recorded, and key measures of diagnostic performance, including adenoma and advanced neoplasia detection rate, were compared among the radiologists. Results: The overall prevalence of histopathologically confirmed advanced neoplasia was 3.6% and did not differ significantly among radiologists (range, 2.4%–4.4%; P = .067; P = .395 when one outlier was excluded). Overall, 19.5% of polyps detected at CT colonography proved to be advanced neoplasia and did not differ significantly among radiologists (range, 14.4%–23.2%; P = .223). The overall per-polyp endoscopic confirmation rate was 93.5%, ranging from 80.0% to 97.6% among radiologists (P = .585). The overall percentage of nondiagnostic CT colonographic examinations was 0.7% and was consistent among radiologists (range, 0.3%–1.1%; P = .509). Conclusion: Consistent performance for adenoma and advanced neoplasia detection, as well as other clinically relevant end points, were observed among radiologists at CT colonographic screening. © RSNA, 2013 PMID:23449954

  8. Gastric emptying evaluation by ultrasound prior colonoscopy: An easy tool following bowel preparation

    PubMed Central

    Coriat, Romain; Polin, Vanessa; Oudjit, Ammar; Henri, Franck; Dhooge, Marion; Leblanc, Sarah; Delchambre, Chantal; Esch, Anouk; Tabouret, Tessa; Barret, Maximilien; Prat, Frédéric; Chaussade, Stanislas

    2014-01-01

    AIM: To investigate the gastric emptying after bowel preparation to allow general anaesthesia. METHODS: A prospective, non-comparative, and non-randomized trial was performed and registered on Eudra CT database (2011-002953-80) and on www.trial.gov (NCT01398098). All patients had a validated indication for colonoscopy and a preparation using sodium phosphate (NaP) tablets. The day of the procedure, patients took 4 tablets with 250 mL of water every 15 min, three times. The gastric volume was estimated every 15 min from computed antral surfaces and weight according to the formula of Perlas et al (Anesthesiology, 2009). Colonoscopy was performed within the 6 h following the last intake. RESULTS: Thirty patients were prospectively included in the study from November 2011 to May 2012. The maximum volume of the antrum was 212 mL, achieved 15 min after the last intake. 24%, 67% and 92% of subjects had an antral volume below 20 mL at 60, 120 and 150 min, respectively. 81% of patients had a Boston score equal to 2 or 3 in each colonic segment. No adverse events leading to treatment discontinuation were reported. CONCLUSION: Gastric volume evaluation appeared to be a simple and reliable method for the assessment of gastric emptying. Data allow considering the NaP tablets bowel preparation in the morning of the procedure and confirming that gastric emptying is achieved after two hours, allowing general anaesthesia. PMID:25309090

  9. The intelligent, painless, "germ-free" colonoscopy: A Columbus' egg for increasing population adherence to colorectal cancer screening?

    PubMed

    Perri, Francesco; Iacobellis, Angelo; Gentile, Marco; Tumino, Emanuele; Andriulli, Angelo

    2010-12-01

    Colorectal cancer (CRC) represents a major cause of morbidity and mortality. Although it is widely accepted that CRC screening in average risk populations lowers CRC incidence and mortality, a disappointedly low adherence rate to both faecal occult blood testing and colonoscopy-based screening programs has been observed in Italy and in other European countries. Main reasons for the low acceptance of colonoscopy-based CRC screening has been ascribed to lack of recommendations given by general practitioners, fear of discomfort or complications, embarrassment, and avoidance of unpleasant preparation. New advances in endoscopic technology such as colon capsule and robotic colonoscopy might represent the ideal tool for CRC screening since they reduce or eliminate procedure-related pain and discomfort. Moreover, no disinfection between procedures is required. Motion of the new probes along the gastrointestinal tract is achieved either in passive modality by utilizing the gut peristalsis (colon capsule) or in active "intelligent" modality by means of computer-assisted propulsion (robotic colonoscopy). In this review, the preliminary clinical results obtained with the new devices are summarized. It is expected that the new instruments will be soon available in clinical practice with the hope of increasing adherence to CRC screening programs. Copyright © 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. Views of supervisors of colonoscopy training on quality issues for the national bowel cancer screening program in Australia.

    PubMed

    Pentti, Marita; Muller, Jennifer; Janda, Monika; Newman, Beth

    2009-02-01

    To describe the views of supervisors of colonoscopy training in regard to colonoscopy training capacity and quality in Australia. Anonymous postal surveys from March to May 2007 were posted to 127 colonoscopy training supervisors (30.2% estimated response rate). The surveys queried colonoscopy training capacity and quality, supervisors' views and opinions on innovative approaches to colonoscopy training, number of colonoscopies and time required by trainees to gain competence in colonoscopy. Approximately 50% of trainers agreed and 27% disagreed that current numbers of training places were adequate to maintain a skilled colonoscopy workforce in preparation for the National Bowel Cancer Screening Program (NBCSP). A collaborative approach with the private sector was seen as beneficial by 65%. Non-gastroenterologists (non-GEs) were more likely than gastroenterologists (GEs) to be of the opinion that simulators are beneficial for colonoscopy training (chi(2)-test = 5.55, P = 0.026). The majority of trainers did not support training either nurses (73%) or general practitioners (GPs) in colonoscopy (71%). Approximately 60% of trainers considered that the current requirements for recognition of training in colonoscopy could be insufficient for trainees to gain competence and 80% of those indicated that > or = 200 colonoscopies were needed. Colonoscopy training in Australia has traditionally followed the apprenticeship model. Projected increases in demand for colonoscopy with the introduction of the NBCSP may require additional training places and new and innovative approaches to training in order to ensure the provision of high-quality colonoscopy services under the NBCSP.

  11. Sixteen-slice multidetector computed tomographic virtual cystoscopy in the evaluation of a patient with suspected bladder tumor and history of bladder carcinoma operation.

    PubMed

    Basak, Muzaffer; Ozkurt, Huseyin; Tanriverdi, Orhan; Cay, Esra; Aydin, Mustafa; Miroglu, Cengiz

    2009-01-01

    The purpose of this study was to evaluate the use of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with suspected bladder tumors and histories of bladder carcinoma operation. Thirty-six patients (29 men and 7 women) with a mean age of 66 years (range, 24-88 years) with suspected bladder tumors and histories of bladder carcinoma operation were included in this prospective study. Virtual cystoscopy was performed by 16-slice multidetector CT scanner. The bladder was filled with diluted contrast material solution through a Foley catheter. Then, all patients underwent conventional cystoscopy examination. Two reviewers found 18 lesions detected by virtual cystoscopy by consensus, whereas 19 lesions were depicted by conventional cystoscopy. At virtual and conventional cystoscopies, the conditions of 3 patients, 2 with chronic inflammations and 1 with foreign body reaction, were wrongly diagnosed as tumors. At conventional cystoscopy, one patient's result was wrongly interpreted as normal. In pathologic evaluation, all tumors were diagnosed as transitional cell carcinoma. Bladder tumor can be noninvasively diagnosed using virtual cystoscopy. Use of virtual cystoscopy should be considered inpatients who present with hematuria or have histories of bladder carcinoma operation and are for follow-up because of its lesser complication risk and its being a less invasive, easily applied procedure without need of anesthesia. In the future, owing to the development of the CT technology and image processing technique, virtual cystoscopy may have a part in the detection of bladder cancer.

  12. Anticipating implementation of colorectal cancer screening in The Netherlands: a nation wide survey on endoscopic supply and demand

    PubMed Central

    2012-01-01

    Background Colorectal cancer (CRC) screening requires sufficient endoscopic resources. The present study aims to determine the Dutch endoscopic production and manpower for 2009, evaluate trends since 2004, determine additional workload which would be caused by implementation of a CRC screening program, and inventory colonoscopy rates performed in other European countries. Methods All Dutch endoscopy units (N = 101) were surveyed for manpower and the numbers of endoscopy procedures performed in 2009. Based on calculations in the report issued by the Dutch Health Council, future additional workload caused by faecal immunochemical test (FIT) screening was estimated. The number of colonoscopies performed in Europe was evaluated by a literature search and an email-inquiry. Results Compared to 2004, there was a 24% increase in total endoscopies (N = 505,226 in 2009), and a 64% increase in colonoscopies (N = 191,339 in 2009) in The Netherlands. The number of endoscopists had increased by 4.6% (N = 583 in 2009). Five years after stepwise implementation of FIT-based CRC screening, endoscopic capacity needs to be increased an additional 15%. A lack of published data on the number of endoscopies performed in Europe was found. Based on our email-inquiry, the number of colonoscopies per 100,000 inhabitants ranged from 126 to 3,031 in 15 European countries. Conclusions Over the last years, endoscopic procedures increased markedly in The Netherlands without a corresponding increase in manpower. A FIT-based CRC screening program requires an estimated additional 15% increase in endoscopic procedures. It is very likely that current colonoscopy density varies widely across European countries. PMID:22280408

  13. Dual energy CT kidney stone differentiation in photon counting computed tomography

    NASA Astrophysics Data System (ADS)

    Gutjahr, R.; Polster, C.; Henning, A.; Kappler, S.; Leng, S.; McCollough, C. H.; Sedlmair, M. U.; Schmidt, B.; Krauss, B.; Flohr, T. G.

    2017-03-01

    This study evaluates the capabilities of a whole-body photon counting CT system to differentiate between four common kidney stone materials, namely uric acid (UA), calcium oxalate monohydrate (COM), cystine (CYS), and apatite (APA) ex vivo. Two different x-ray spectra (120 kV and 140 kV) were applied and two acquisition modes were investigated. The macro-mode generates two energy threshold based image-volumes and two energy bin based image-volumes. In the chesspattern-mode four energy thresholds are applied. A virtual low energy image, as well as a virtual high energy image are derived from initial threshold-based images, while considering their statistically correlated nature. The energy bin based images of the macro-mode, as well as the virtual low and high energy image of the chesspattern-mode serve as input for our dual energy evaluation. The dual energy ratio of the individually segmented kidney stones were utilized to quantify the discriminability of the different materials. The dual energy ratios of the two acquisition modes showed high correlation for both applied spectra. Wilcoxon-rank sum tests and the evaluation of the area under the receiver operating characteristics curves suggest that the UA kidney stones are best differentiable from all other materials (AUC = 1.0), followed by CYS (AUC ≍ 0.9 compared against COM and APA). COM and APA, however, are hardly distinguishable (AUC between 0.63 and 0.76). The results hold true for the measurements of both spectra and both acquisition modes.

  14. Automated synthesis, insertion and detection of polyps for CT colonography

    NASA Astrophysics Data System (ADS)

    Sezille, Nicolas; Sadleir, Robert J. T.; Whelan, Paul F.

    2003-03-01

    CT Colonography (CTC) is a new non-invasive colon imaging technique which has the potential to replace conventional colonoscopy for colorectal cancer screening. A novel system which facilitates automated detection of colorectal polyps at CTC is introduced. As exhaustive testing of such a system using real patient data is not feasible, more complete testing is achieved through synthesis of artificial polyps and insertion into real datasets. The polyp insertion is semi-automatic: candidate points are manually selected using a custom GUI, suitable points are determined automatically from an analysis of the local neighborhood surrounding each of the candidate points. Local density and orientation information are used to generate polyps based on an elliptical model. Anomalies are identified from the modified dataset by analyzing the axial images. Detected anomalies are classified as potential polyps or natural features using 3D morphological techniques. The final results are flagged for review. The system was evaluated using 15 scenarios. The sensitivity of the system was found to be 65% with 34% false positive detections. Automated diagnosis at CTC is possible and thorough testing is facilitated by augmenting real patient data with computer generated polyps. Ultimately, automated diagnosis will enhance standard CTC and increase performance.

  15. [A Case of Lymph Node Metastasis of Rectal Laterally Spreading Tumor with Mucosal Cancer after Endoscopic Submucosal Dissection].

    PubMed

    Ushigome, Hajime; Fujimoto, Yoshiya; Suzuki, Shinsuke; Minami, Hironori; Miyanari, Shun; Murahashi, Satoshi; Fukuoka, Hironori; Nagasaki, Toshiya; Akiyoshi, Takashi; Konishi, Tsuyoshi; Nagayama, Satoshi; Fukunaga, Yosuke; Ueno, Masashi; Chino, Akiko; Igarashi, Masahiro

    2017-11-01

    A screening fecal occult blood test was positive in a 76-year-old female. Colonoscopy showed laterally spreading tumor (LST)over 15 cm at lower rectum. endoscopic submucosal dissection(ESD)was performed. Pathological findings showed LST-G, 150×100 mm, adenocarcinoma(tub1-tub2), tubular adenoma, moderate-severe atypia, Tis(M), ly(-), v(-), HMX, VMX. Two years later CT detected one swollen lymph node at mesorectum and PET-CT showed FDG up take at the lymph node. We diagnosed lymph node metastasis, performed laparoscopic very low anterior resection. Pathological findings showed one lymph node metastasis, but there were no residual cancer at rectum. We cut the surgical specimen at 5mm intervals because of it's big size. It might be impossible with this procedure to detect SM invasion at this specimen.

  16. Quantitative Comparison of Virtual Monochromatic Images of Dual Energy Computed Tomography Systems: Beam Hardening Artifact Correction and Variance in Computed Tomography Numbers: A Phantom Study.

    PubMed

    Wu, Rongli; Watanabe, Yoshiyuki; Satoh, Kazuhiko; Liao, Yen-Peng; Takahashi, Hiroto; Tanaka, Hisashi; Tomiyama, Noriyuki

    2018-05-21

    The aim of this study was to quantitatively compare the reduction in beam hardening artifact (BHA) and variance in computed tomography (CT) numbers of virtual monochromatic energy (VME) images obtained with 3 dual-energy computed tomography (DECT) systems at a given radiation dose. Five different iodine concentrations were scanned using dual-energy and single-energy (120 kVp) modes. The BHA and CT number variance were evaluated. For higher iodine concentrations, 40 and 80 mgI/mL, BHA on VME imaging was significantly decreased when the energy was higher than 50 keV (P = 0.003) and 60 keV (P < 0.001) for GE, higher than 80 keV (P < 0.001) and 70 keV (P = 0.002) for Siemens, and higher than 40 keV (P < 0.001) and 60 keV (P < 0.001) for Toshiba, compared with single-energy CT imaging. Virtual monochromatic energy imaging can decrease BHA and improve CT number accuracy in different dual-energy computed tomography systems, depending on energy levels and iodine concentrations.

  17. ACA-mandated elimination of cost sharing for preventive screening has had limited early impact.

    PubMed

    Mehta, Shivan J; Polsky, Daniel; Zhu, Jingsan; Lewis, James D; Kolstad, Jonathan T; Loewenstein, George; Volpp, Kevin G

    2015-07-01

    The Affordable Care Act eliminated patient cost sharing for evidence-based preventive care, yet the impact of this policy on colonoscopy and mammography rates is unclear. We examined the elimination of cost sharing among small business beneficiaries of Humana, a large national insurer. This was a retrospective interrupted time series analysis of whether the change in cost-sharing policy was associated with a change in screening utilization, using grandfathered plans as a comparison group. We compared beneficiaries in small business nongrandfathered plans that were required to eliminate cost sharing (intervention) with those in grandfathered plans that did not have to change cost sharing (control). There were 63,246 men and women aged 50 to 64 years eligible for colorectal cancer screening, and 30,802 women aged 50 to 64 years eligible for breast cancer screening. The primary outcome variables were rates of colonoscopy and mammography per person-month, with secondary analysis of colonoscopy rates coded as preventive only. There was no significant change in the level or slope of colonoscopy and mammography utilization for intervention plans relative to the control plans. There was also no significant relevant change among those colonoscopies coded as preventive. The results suggest that the implementation of the policy is not having its intended effects, as cost sharing rates for colonoscopy and mammography did not change substantially, and utilization of colonoscopy and mammography changed little, following this new policy approach.

  18. Ultrashort echo-time MRI versus CT for skull aberration correction in MR-guided transcranial focused ultrasound: In vitro comparison on human calvaria.

    PubMed

    Miller, G Wilson; Eames, Matthew; Snell, John; Aubry, Jean-François

    2015-05-01

    Transcranial magnetic resonance-guided focused ultrasound (TcMRgFUS) brain treatment systems compensate for skull-induced beam aberrations by adjusting the phase and amplitude of individual ultrasound transducer elements. These corrections are currently calculated based on a preacquired computed tomography (CT) scan of the patient's head. The purpose of the work presented here is to demonstrate the feasibility of using ultrashort echo-time magnetic resonance imaging (UTE MRI) instead of CT to calculate and apply aberration corrections on a clinical TcMRgFUS system. Phantom experiments were performed in three ex-vivo human skulls filled with tissue-mimicking hydrogel. Each skull phantom was imaged with both CT and UTE MRI. The MR images were then segmented into "skull" and "not-skull" pixels using a computationally efficient, threshold-based algorithm, and the resulting 3D binary skull map was converted into a series of 2D virtual CT images. Each skull was mounted in the head transducer of a clinical TcMRgFUS system (ExAblate Neuro, Insightec, Israel), and transcranial sonications were performed using a power setting of approximately 750 acoustic watts at several different target locations within the electronic steering range of the transducer. Each target location was sonicated three times: once using aberration corrections calculated from the actual CT scan, once using corrections calculated from the MRI-derived virtual CT scan, and once without applying any aberration correction. MR thermometry was performed in conjunction with each 10-s sonication, and the highest single-pixel temperature rise and surrounding-pixel mean were recorded for each sonication. The measured temperature rises were ∼ 45% larger for aberration-corrected sonications than for noncorrected sonications. This improvement was highly significant (p < 10(-4)). The difference between the single-pixel peak temperature rise and the surrounding-pixel mean, which reflects the sharpness of the thermal focus, was also significantly larger for aberration-corrected sonications. There was no significant difference between the sonication results achieved using CT-based and MR-based aberration correction. The authors have demonstrated that transcranial focal heating can be significantly improved in vitro by using UTE MRI to compute skull-induced ultrasound aberration corrections. Their results suggest that UTE MRI could be used instead of CT to implement such corrections on current 0.7 MHz clinical TcMRgFUS devices. The MR image acquisition and segmentation procedure demonstrated here would add less than 15 min to a clinical MRgFUS treatment session.

  19. Single stage treatment of ankylosis of the temporomandibular joint using patient-specific total joint replacement and virtual surgical planning.

    PubMed

    Haq, Jahrad; Patel, Nishma; Weimer, Katherine; Matthews, N Shaun

    2014-04-01

    Ankylosis of the temporomandibular joint (TMJ) is a debilitating condition that can result in pain, trismus, and a poor quality of life. It can be caused by injury, infection, and rheumatoid disease. Current management includes gap arthroplasty, interpositional arthroplasty, and reconstruction. Traditionally, joints are reconstructed using stock implants, or the procedure is done in two stages with an additional computed tomography (CT) scan between the resective and reconstructive procedures and use of stereolithographic models to aid the design of the definitive prostheses. We describe a technique for the resection of ankylosis and reconstruction of the joint in a single operation using virtually designed custom-made implants. Five patients with ankylosis of the TMJ had a single stage operation with reconstruction between 2010 and 2012. All had preoperative high-resolution CT with contrast angiography. During an international web-based teleconference between the surgeon and the engineer a virtual resection of the ankylosis was done using the reconstructed CT images. The bespoke cutting guides and implants were designed virtually at the same time and were then manufactured precisely using computer-aided design and manufacture (CAD-CAM) over 6 weeks. After release of the ankylosis and reconstruction, the patients underwent an exercise regimen to improve mouth opening. Follow-up was for a minimum of 6 months. Four patients had one operation, and one patient had two. Median/Mean maximum incisal opening increased from 0.6mm before operation to 25 mm afterwards (range 23-27), and there was minimal surgical morbidity. This new method effectively treats ankylosis of the TMJ in a single stage procedure. Fewer operations and hospital stays, and the maintenance of overall clinical outcome are obvious advantages. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  20. A virtual simulator designed for collision prevention in proton therapy.

    PubMed

    Jung, Hyunuk; Kum, Oyeon; Han, Youngyih; Park, Hee Chul; Kim, Jin Sung; Choi, Doo Ho

    2015-10-01

    In proton therapy, collisions between the patient and nozzle potentially occur because of the large nozzle structure and efforts to minimize the air gap. Thus, software was developed to predict such collisions between the nozzle and patient using treatment virtual simulation. Three-dimensional (3D) modeling of a gantry inner-floor, nozzle, and robotic-couch was performed using SolidWorks based on the manufacturer's machine data. To obtain patient body information, a 3D-scanner was utilized right before CT scanning. Using the acquired images, a 3D-image of the patient's body contour was reconstructed. The accuracy of the image was confirmed against the CT image of a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of the gantry, nozzle, and couch in real scale. A collision, if any, was examined both in static and dynamic modes. The static mode assessed collisions only at fixed positions of the machine's components, while the dynamic mode operated any time a component was in motion. A collision was identified if any voxels of two components, e.g., the nozzle and the patient or couch, overlapped when calculating volume locations. The event and collision point were visualized, and collision volumes were reported. All components were successfully assembled, and the motions were accurately controlled. The 3D-shape of the phantom agreed with CT images within a deviation of 2 mm. Collision situations were simulated within minutes, and the results were displayed and reported. The developed software will be useful in improving patient safety and clinical efficiency of proton therapy.

  1. Comparative effectiveness and cost-effectiveness of screening colonoscopy vs. sigmoidoscopy and alternative strategies.

    PubMed

    Sharaf, Ravi N; Ladabaum, Uri

    2013-01-01

    Fecal occult blood testing (FOBT) and sigmoidoscopy are proven to decrease colorectal cancer (CRC) incidence and mortality. Sigmoidoscopy's benefit is limited to the distal colon. Observational data are conflicting regarding the degree to which colonoscopy affords protection against proximal CRC. Our aim was to explore the comparative effectiveness and cost-effectiveness of colonoscopy vs. sigmoidoscopy and alternative CRC screening strategies in light of the latest published data. We performed a contemporary cost-utility analysis using a Markov model validated against data from randomized controlled trials of FOBT and sigmoidoscopy. Persons at average CRC risk within the general US population were modeled. Screening strategies included those recommended by the United States (US) Preventive Services Task Force, including colonoscopy every 10 years (COLO), flexible sigmoidoscopy every 5 years (FS), annual fecal occult blood testing, annual fecal immunochemical testing (FIT), and the combination FS/FIT. The main outcome measures were quality-adjusted life-years (QALYs) and costs. In the base case, FIT dominated other strategies. The advantage of FIT over FS and COLO was contingent on rates of uptake and adherence that are well above current US rates. Compared with FIT, FS and COLO both cost <$50,000/QALY gained when FIT per-cycle adherence was <50%. COLO cost $56,800/QALY gained vs. FS in the base case. COLO cost <$100,000/QALY gained vs. FS when COLO yielded a relative risk of proximal CRC of <0.5 vs. no screening. In probabilistic analyses, COLO was cost-effective vs. FS at a willingness-to-pay threshold of $100,000/QALY gained in 84% of iterations. Screening colonoscopy may be cost-effective compared with FIT and sigmoidoscopy, depending on the relative rates of screening uptake and adherence and the protective benefit of colonoscopy in the proximal colon. Colonoscopy's cost-effectiveness compared with sigmoidoscopy is contingent on the ability to deliver ~50% protection against CRC in the proximal colon.

  2. Effectiveness of screening colonoscopy in reducing the risk of death from right and left colon cancer: a large community-based study.

    PubMed

    Doubeni, Chyke A; Corley, Douglas A; Quinn, Virginia P; Jensen, Christopher D; Zauber, Ann G; Goodman, Michael; Johnson, Jill R; Mehta, Shivan J; Becerra, Tracy A; Zhao, Wei K; Schottinger, Joanne; Doria-Rose, V Paul; Levin, Theodore R; Weiss, Noel S; Fletcher, Robert H

    2018-02-01

    Screening colonoscopy's effectiveness in reducing colorectal cancer mortality risk in community populations is unclear, particularly for right-colon cancers, leading to recommendations against its use for screening in some countries. This study aimed to determine whether, among average-risk people, receipt of screening colonoscopy reduces the risk of dying from both right-colon and left-colon/rectal cancers. We conducted a nested case-control study with incidence-density matching in screening-eligible Kaiser Permanente members. Patients who were 55-90 years old on their colorectal cancer death date during 2006-2012 were matched on diagnosis (reference) date to controls on age, sex, health plan enrolment duration and geographical region. We excluded patients at increased colorectal cancer risk, or with prior colorectal cancer diagnosis or colectomy. The association between screening colonoscopy receipt in the 10-year period before the reference date and colorectal cancer death risk was evaluated while accounting for other screening exposures. We analysed 1747 patients who died from colorectal cancer and 3460 colorectal cancer-free controls. Compared with no endoscopic screening, receipt of a screening colonoscopy was associated with a 67% reduction in the risk of death from any colorectal cancer (adjusted OR (aOR)=0.33, 95% CI 0.21 to 0.52). By cancer location, screening colonoscopy was associated with a 65% reduction in risk of death for right-colon cancers (aOR=0.35, CI 0.18 to 0.65) and a 75% reduction for left-colon/rectal cancers (aOR=0.25, CI 0.12 to 0.53). Screening colonoscopy was associated with a substantial and comparably decreased mortality risk for both right-sided and left-sided cancers within a large community-based population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Technical Note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michalak, Gregory; Grimes, Joshua; Fletcher, Joel

    2016-01-15

    Purpose: The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Methods: Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kVmore » beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Results: Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. Conclusions: The authors’ report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.« less

  4. Technical Note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging.

    PubMed

    Michalak, Gregory; Grimes, Joshua; Fletcher, Joel; Halaweish, Ahmed; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia

    2016-01-01

    The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kV beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. The authors' report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.

  5. Colorectal Cancer Screening Based on Age and Gender

    PubMed Central

    Wong, Martin C.S.; Ching, Jessica Y.L.; Chan, Victor C.W.; Lam, Thomas Y.T.; Luk, Arthur K.C.; Wong, Sunny H.; Ng, Siew C.; Ng, Simon S.M.; Wu, Justin C.Y.; Chan, Francis K.L.; Sung, Joseph J.Y.

    2016-01-01

    Abstract We evaluated whether age- and gender-based colorectal cancer screening is cost-effective. Recent studies in the United States identified age and gender as 2 important variables predicting advanced proximal neoplasia, and that women aged <60 to 70 years were more suited for sigmoidoscopy screening due to their low risk of proximal neoplasia. Yet, quantitative assessment of the incremental benefits, risks, and cost remains to be performed. Primary care screening practice (2008–2015). A Markov modeling was constructed using data from a screening cohort. The following strategies were compared according to the Incremental Cost Effectiveness Ratio (ICER) for 1 life-year saved: flexible sigmoidoscopy (FS) 5 yearly; colonoscopy 10 yearly; FS for each woman at 50- and 55-year old followed by colonoscopy at 60- and 70-year old; FS for each woman at 50-, 55-, 60-, and 65-year old followed by colonoscopy at 70-year old; FS for each woman at 50-, 55-, 60-, 65-, and 70-year old. All male subjects received colonoscopy at 50-, 60-, and 70-year old under strategies 3 to 5. From a hypothetical population of 100,000 asymptomatic subjects, strategy 2 could save the largest number of life-years (4226 vs 2268 to 3841 by other strategies). When compared with no screening, strategy 5 had the lowest ICER (US$42,515), followed by strategy 3 (US$43,517), strategy 2 (US$43,739), strategy 4 (US$47,710), and strategy 1 (US$56,510). Strategy 2 leads to the highest number of bleeding and perforations, and required a prohibitive number of colonoscopy procedures. Strategy 5 remains the most cost-effective when assessed with a wide range of deterministic sensitivity analyses around the base case. From the cost effectiveness analysis, FS for women and colonoscopy for men represent an economically favorable screening strategy. These findings could inform physicians and policy-makers in triaging eligible subjects for risk-based screening, especially in countries with limited colonoscopic resources. Future research should study the acceptability, feasibility, and feasibility of this risk-based strategy in different populations. PMID:26962772

  6. Limited-preparation CT colonography in frail elderly patients: a feasibility study.

    PubMed

    Keeling, Aoife N; Slattery, Michael M; Leong, Sum; McCarthy, Eoghan; Susanto, Maja; Lee, Michael J; Morrin, Martina M

    2010-05-01

    Full colonic preparation can be onerous and may be poorly tolerated in frail elderly patients. The purpose of this study was to prospectively assess the image quality and diagnostic yield of limited-preparation CT colonography (CTC) in elderly patients with suspected colorectal cancer who were deemed medically unfit or unsuitable for colonoscopy. A prospective study was performed of 67 elderly patients with reduced functional status referred for CTC. Participants were prescribed a limited bowel preparation consisting of a low-residue diet for 3 days, 1 L of 2% oral diatrizoate meglumine (Gastrografin) 24 hours before CTC, and 1 L of 2% oral Gastrografin over the 2 hours immediately before CTC. No cathartic preparation was administered. All colonic segments were graded from 1 to 5 for image quality (1, unreadable; 2, poor; 3, equivocal; 4, good; 5, excellent) and reader confidence. Clinical and conventional colonoscopy follow-up findings were documented, and all colonic and extracolonic pathologic findings were documented. Overall image quality and reader confidence in the evaluation of the colon was rated good or excellent in 84% of the colonic segments. Colonic abnormalities were identified in 12 patients (18%), including four colonic tumors, two polyps, and seven colonic strictures. Incidental extraintestinal findings were detected in 43 patients (64%), including nine patients with lesions radiologically consistent with malignancy. Limited-preparation low-dose CTC is a feasible and useful minimally invasive technique with which to evaluate the colon and exclude gross pathology (mass lesions and polyps > 1 cm) in elderly patients with diminished performance status, yielding good to excellent image quality.

  7. Colorectal cancer screening: Estimated future colonoscopy need and current volume and capacity.

    PubMed

    Joseph, Djenaba A; Meester, Reinier G S; Zauber, Ann G; Manninen, Diane L; Winges, Linda; Dong, Fred B; Peaker, Brandy; van Ballegooijen, Marjolein

    2016-08-15

    In 2014, a national campaign was launched to increase colorectal cancer (CRC) screening rates in the United States to 80% by 2018; it is unknown whether there is sufficient colonoscopy capacity to reach this goal. This study estimated the number of colonoscopies needed to screen 80% of the eligible population with fecal immunochemical testing (FIT) or colonoscopy and determined whether there was sufficient colonoscopy capacity to meet the need. The Microsimulation Screening Analysis-Colon model was used to simulate CRC screening test use in the United States (2014-2040); the implementation of a national screening program in 2014 with FIT or colonoscopy with 80% participation was assumed. The 2012 Survey of Endoscopic Capacity (SECAP) estimated the number of colonoscopies that were performed and the number that could be performed. If a national screening program started in 2014, by 2024, approximately 47 million FIT procedures and 5.1 million colonoscopies would be needed annually to screen the eligible population with a program using FIT as the primary screening test; approximately 11 to 13 million colonoscopies would be needed annually to screen the eligible population with a colonoscopy-only screening program. According to the SECAP survey, an estimated 15 million colonoscopies were performed in 2012, and an additional 10.5 million colonoscopies could be performed. The estimated colonoscopy capacity is sufficient to screen 80% of the eligible US population with FIT, colonoscopy, or a mix of tests. Future analyses should take into account the geographic distribution of colonoscopy capacity. Cancer 2016;122:2479-86. © 2016 American Cancer Society. © 2016 American Cancer Society.

  8. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  9. Objective image characterization of a spectral CT scanner with dual-layer detector

    NASA Astrophysics Data System (ADS)

    Ozguner, Orhan; Dhanantwari, Amar; Halliburton, Sandra; Wen, Gezheng; Utrup, Steven; Jordan, David

    2018-01-01

    This work evaluated the performance of a detector-based spectral CT system by obtaining objective reference data, evaluating attenuation response of iodine and accuracy of iodine quantification, and comparing conventional CT and virtual monoenergetic images in three common phantoms. Scanning was performed using the hospital’s clinical adult body protocol. Modulation transfer function (MTF) was calculated for a tungsten wire and visual line pair targets were evaluated. Image noise power spectrum (NPS) and pixel standard deviation were calculated. MTF for monoenergetic images agreed with conventional images within 0.05 lp cm-1. NPS curves indicated that noise texture of 70 keV monoenergetic images is similar to conventional images. Standard deviation measurements showed monoenergetic images have lower noise except at 40 keV. Mean CT number and CNR agreed with conventional images at 75 keV. Measured iodine concentration agreed with true concentration within 6% for inserts at the center of the phantom. Performance of monoenergetic images at detector based spectral CT is the same as, or better than, that of conventional images. Spectral acquisition and reconstruction with a detector based platform represents the physical behaviour of iodine as expected and accurately quantifies the material concentration.

  10. Recent advances in 3D computed tomography techniques for simulation and navigation in hepatobiliary pancreatic surgery.

    PubMed

    Uchida, Masafumi

    2014-04-01

    A few years ago it could take several hours to complete a 3D image using a 3D workstation. Thanks to advances in computer science, obtaining results of interest now requires only a few minutes. Many recent 3D workstations or multimedia computers are equipped with onboard 3D virtual patient modeling software, which enables patient-specific preoperative assessment and virtual planning, navigation, and tool positioning. Although medical 3D imaging can now be conducted using various modalities, including computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), and ultrasonography (US) among others, the highest quality images are obtained using CT data, and CT images are now the most commonly used source of data for 3D simulation and navigation image. If the 2D source image is bad, no amount of 3D image manipulation in software will provide a quality 3D image. In this exhibition, the recent advances in CT imaging technique and 3D visualization of the hepatobiliary and pancreatic abnormalities are featured, including scan and image reconstruction technique, contrast-enhanced techniques, new application of advanced CT scan techniques, and new virtual reality simulation and navigation imaging. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  11. Mastoid Cavity Dimensions and Shape: Method of Measurement and Virtual Fitting of Implantable Devices

    PubMed Central

    Handzel, Ophir; Wang, Haobing; Fiering, Jason; Borenstein, Jeffrey T.; Mescher, Mark J.; Leary Swan, Erin E.; Murphy, Brian A.; Chen, Zhiqiang; Peppi, Marcello; Sewell, William F.; Kujawa, Sharon G.; McKenna, Michael J.

    2009-01-01

    Temporal bone implants can be used to electrically stimulate the auditory nerve, to amplify sound, to deliver drugs to the inner ear and potentially for other future applications. The implants require storage space and access to the middle or inner ears. The most acceptable space is the cavity created by a canal wall up mastoidectomy. Detailed knowledge of the available space for implantation and pathways to access the middle and inner ears is necessary for the design of implants and successful implantation. Based on temporal bone CT scans a method for three-dimensional reconstruction of a virtual canal wall up mastoidectomy space is described. Using Amira® software the area to be removed during such surgery is marked on axial CT slices, and a three-dimensional model of that space is created. The average volume of 31 reconstructed models is 12.6 cm3 with standard deviation of 3.69 cm3, ranging from 7.97 to 23.25 cm3. Critical distances were measured directly from the model and their averages were calculated: height 3.69 cm, depth 2.43 cm, length above the external auditory canal (EAC) 4.45 cm and length posterior to EAC 3.16 cm. These linear measurements did not correlate well with volume measurements. The shape of the models was variable to a significant extent making the prediction of successful implantation for a given design based on linear and volumetric measurement unreliable. Hence, to assure successful implantation, preoperative assessment should include a virtual fitting of an implant into the intended storage space. The above-mentioned three-dimensional models were exported from Amira to a Solidworks application where virtual fitting was performed. Our results are compared to other temporal bone implant virtual fitting studies. Virtual fitting has been suggested for other human applications. PMID:19372649

  12. Dual-energy CT and ceramic or titanium prostheses material reduce CT artifacts and provide superior image quality of total knee arthroplasty.

    PubMed

    Kasparek, Maximilian F; Töpker, Michael; Lazar, Mathias; Weber, Michael; Kasparek, Michael; Mang, Thomas; Apfaltrer, Paul; Kubista, Bernd; Windhager, Reinhard; Ringl, Helmut

    2018-06-07

    To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.

  13. The virtual morphology and the main movements of the human neck simulations used for car crash studies

    NASA Astrophysics Data System (ADS)

    Ciunel, St.; Tica, B.

    2016-08-01

    The paper presents the studies made on a similar biomechanical system composed by neck, head and thorax bones. The models were defined in a CAD environment which includes Adams algorithm for dynamic simulations. The virtual models and the entire morphology were obtained starting with CT images made on a living human subject. The main movements analyzed were: axial rotation (left-right), lateral bending (left-right) and flexion- extension movement. After simulation was obtained the entire biomechanical behavior based on data tables or diagrams. That virtual model composed by neck and head can be included in complex system (as a car system) and supposed to several impact simulations (virtual crash tests). Also, our research team built main components of a testing device for dummy car crash neck-head system using anatomical data.

  14. Detection of Bone Marrow Edema in Nondisplaced Hip Fractures: Utility of a Virtual Noncalcium Dual-Energy CT Application.

    PubMed

    Kellock, Trenton T; Nicolaou, Savvas; Kim, Sandra S Y; Al-Busaidi, Sultan; Louis, Luck J; O'Connell, Tim W; Ouellette, Hugue A; McLaughlin, Patrick D

    2017-09-01

    Purpose To quantify the sensitivity and specificity of dual-energy computed tomographic (CT) virtual noncalcium images in the detection of nondisplaced hip fractures and to assess whether obtaining these images as a complement to bone reconstructions alters sensitivity, specificity, or diagnostic confidence. Materials and Methods The clinical research ethics board approved chart review, and the requirement to obtain informed consent was waived. The authors retrospectively identified 118 patients who presented to a level 1 trauma center emergency department and who underwent dual-energy CT for suspicion of a nondisplaced traumatic hip fracture. Clinical follow-up was the standard of reference. Three radiologists interpreted virtual noncalcium images for traumatic bone marrow edema. Bone reconstructions for the same cases were interpreted alone and then with virtual noncalcium images. Diagnostic confidence was rated on a scale of 1 to 10. McNemar, Fleiss κ, and Wilcoxon signed-rank tests were used for statistical analysis. Results Twenty-two patients had nondisplaced hip fractures and 96 did not have hip fractures. Sensitivity with virtual noncalcium images was 77% and 91% (17 and 20 of 22 patients), and specificity was 92%-99% (89-95 of 96 patients). Sensitivity increased by 4%-5% over that with bone reconstruction images alone for two of the three readers when both bone reconstruction and virtual noncalcium images were used. Specificity remained unchanged (99% and 100%). Diagnostic confidence in the exclusion of fracture was improved with combined bone reconstruction and virtual noncalcium images (median score: 10, 9, and 10 for readers 1, 2, and 3, respectively) compared with bone reconstruction images alone (median score: 9, 8, and 9). Conclusion When used as a supplement to standard bone reconstructions, dual-energy CT virtual noncalcium images increased sensitivity for the detection of nondisplaced traumatic hip fractures and improved diagnostic confidence in the exclusion of these fractures. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on March 17, 2017.

  15. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2007-03-01

    Multislice CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multislice CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. Moreover, we have provided diagnostic assistance methods to medical screening specialists by using a lung cancer screening algorithm built into mobile helical CT scanner for the lung cancer mass screening done in the region without the hospital. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.

  16. High definition plus colonoscopy combined with i-scan tone enhancement vs. high definition colonoscopy for colorectal neoplasia: A randomized trial.

    PubMed

    Hoffman, Arthur; Loth, Linn; Rey, Johannes Wilhelm; Rahman, Fareed; Goetz, Martin; Hansen, Torsten; Tresch, Achim; Niederberger, Theresa; Galle, Peter Robert; Kiesslich, Ralf

    2014-11-01

    High definition endoscopy is the accepted standard in colonoscopy. However, an important problem is missed polyps. Our objective was to assess the additional adenoma detection rate between high definition colonoscopy with tone enhancement (digital chromoendoscopy) vs. white light high definition colonoscopy. In this prospective randomized trial patients were included to undergo a tandem colonoscopy. The first exam was a white light colonoscopy with removal of all visualized polyps. The second examination was randomly assigned in a 1:1 ratio as either again white light colonoscopy (Group A) or colonoscopy with tone enhancement (Group B). Primary endpoint was the adenoma detection rate during the second withdrawal (sample size calculation - 40 per group). 67 lesions (Group A: n=34 vs. Group B: n=33) in 80 patients (mean age 61 years, male 64%) were identified on the first colonoscopy. The second colonoscopy detected 78 additional lesions: n=60 with tone enhancement vs. n=18 with white light endoscopy (p<0.001). Tone enhancement found more additional adenomas (A n=20 vs. B n=6, p=0.006) and identified significantly more missed adenomas per subject (0.5 vs. 0.15, p=0.006). High definition plus colonoscopy with tone enhancement detected more adenomas missed by white light colonoscopy. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Determination of colonoscopy indication from administrative claims data.

    PubMed

    Ko, Cynthia W; Dominitz, Jason A; Neradilek, Moni; Polissar, Nayak; Green, Pam; Kreuter, William; Baldwin, Laura-Mae

    2014-04-01

    Colonoscopy outcomes, such as polyp detection or complication rates, may differ by procedure indication. To develop methods to classify colonoscopy indications from administrative data, facilitating study of colonoscopy quality and outcomes. We linked 14,844 colonoscopy reports from the Clinical Outcomes Research Initiative, a national repository of endoscopic reports, to the corresponding Medicare Carrier and Outpatient File claims. Colonoscopy indication was determined from the procedure reports. We developed algorithms using classification and regression trees and linear discriminant analysis (LDA) to classify colonoscopy indication. Predictor variables included ICD-9CM and CPT/HCPCS codes present on the colonoscopy claim or in the 12 months prior, patient demographics, and site of colonoscopy service. Algorithms were developed on a training set of 7515 procedures, then validated using a test set of 7329 procedures. Sensitivity was lowest for identifying average-risk screening colonoscopies, varying between 55% and 86% for the different algorithms, but specificity for this indication was consistently over 95%. Sensitivity for diagnostic colonoscopy varied between 77% and 89%, with specificity between 55% and 87%. Algorithms with classification and regression trees with 7 variables or LDA with 10 variables had similar overall accuracy, and generally lower accuracy than the algorithm using LDA with 30 variables. Algorithms using Medicare claims data have moderate sensitivity and specificity for colonoscopy indication, and will be useful for studying colonoscopy quality in this population. Further validation may be needed before use in alternative populations.

  18. Can we ease the financial burden of colonoscopy? Using real-time endoscopic assessment of polyp histology to predict surveillance intervals.

    PubMed

    Chandran, S; Parker, F; Lontos, S; Vaughan, R; Efthymiou, M

    2015-12-01

    Polyps identified at colonoscopy are predominantly diminutive (<5 mm) with a small risk (>1%) of high-grade dysplasia or carcinoma; however, the cost of histological assessment is substantial. The aim of this study was to determine whether prediction of colonoscopy surveillance intervals based on real-time endoscopic assessment of polyp histology is accurate and cost effective. A prospective cohort study was conducted across a tertiary care and private community hospital. Ninety-four patients underwent colonoscopy and polypectomy of diminutive (≤5 mm) polyps from October 2012 to July 2013, yielding a total of 159 polyps. Polyps were examined and classified according to the Sano-Emura classification system. The endoscopic assessment (optical diagnosis) of polyp histology was used to predict appropriate colonoscopy surveillance intervals. The main outcome measure was the accuracy of optical diagnosis of diminutive colonic polyps against the gold standard of histological assessment. Optical diagnosis was correct in 105/108 (97.2%) adenomas. This yielded a sensitivity, specificity and positive and negative predictive values (with 95%CI) of 97.2% (92.1-99.4%), 78.4% (64.7-88.7%), 90.5% (83.7-95.2%) and 93% (80.9-98.5%) respectively. Ninety-two (98%) patients were correctly triaged to their repeat surveillance colonoscopy. Based on these findings, a cut and discard approach would have resulted in a saving of $319.77 per patient. Endoscopists within a tertiary care setting can accurately predict diminutive polyp histology and confer an appropriate surveillance interval with an associated financial benefit to the healthcare system. However, limitations to its application in the community setting exist, which may improve with further training and high-definition colonoscopes. © 2015 Royal Australasian College of Physicians.

  19. The incidence of post-colonoscopy colorectal cancer: a retrospective long-term cohort study using a colonoscopy database.

    PubMed

    Nakada, Ayako; Niikura, Ryota; Yamada, Atsuo; Yoshida, Shuntaro; Hirata, Yoshihiro; Koike, Kazuhiko

    2017-06-01

    The cumulative incidence of post-colonoscopy colorectal cancer remains unclear. Our aims were to estimate the incidence of and identify risk factors associated with post-colonoscopy colorectal cancer. We conducted a retrospective cohort study using the colonoscopy database of the Department of Gastroenterology, the University of Tokyo Hospital Records from1995-2012. A cohort of 2544 patients, who received multiple colonoscopies without colorectal cancer findings at first colonoscopy, was selected. The primary outcome was post-colonoscopy colorectal cancer; data were censored at the date of final colonoscopy. We assessed patients' background characteristics, colonoscopy findings, and cancer characteristics, including location and size. The cumulative incidence of colorectal cancer was evaluated, and a Cox proportional hazards model was used to estimate hazard ratios (HRs). Colorectal cancer was identified in seven (0.77/1000 person-years) patients during the mean follow-up period of 3.6 years (maximum, 17 years). The cumulative incidence of colorectal cancer was 0, 0.47, 0.62, and 0.62% at 1, 5, 10, and 15 years, respectively. Cancer was identified in the rectum in five of seven patients. Polyp size >10 mm (HR 5.7, p = 0.023) and intubation time >30 min (HR 11.6, p = 0.003) at first colonoscopy were associated significantly with an increased incidence of post-colonoscopy colorectal cancer. Although several factors were associated with an increased risk of post-colonoscopy colorectal cancer, the incidence of this disease might be low in patients who received at least twice colonoscopy. High proportion of rectal cancer in post-colonoscopy colorectal cancer should be noted.

  20. Delivering an Online Translation Course

    ERIC Educational Resources Information Center

    Campbell, Dermot F.

    2004-01-01

    This presentation is a discursive treatment of the migration of a classroom based translation class to online delivery using the Virtual Learning Environment WebCT. The main focus is not on the VLE itself, but on the pedagogical challenges posed by the move to online delivery and the course structure developed to retain as many of the advantages…

  1. Cost-effectiveness of competing strategies for management of recurrent Clostridium difficile infection: a decision analysis.

    PubMed

    Konijeti, Gauree G; Sauk, Jenny; Shrime, Mark G; Gupta, Meera; Ananthakrishnan, Ashwin N

    2014-06-01

    Clostridium difficile infection (CDI) is an important cause of morbidity and healthcare costs, and is characterized by high rates of disease recurrence. The cost-effectiveness of newer treatments for recurrent CDI has not been examined, yet would be important to inform clinical practice. The aim of this study was to analyze the cost effectiveness of competing strategies for recurrent CDI. We constructed a decision-analytic model comparing 4 treatment strategies for first-line treatment of recurrent CDI in a population with a median age of 65 years: metronidazole, vancomycin, fidaxomicin, and fecal microbiota transplant (FMT). We modeled up to 2 additional recurrences following the initial recurrence. We assumed FMT delivery via colonoscopy as our base case, but conducted sensitivity analyses based on different modes of delivery. Willingness-to-pay threshold was set at $50 000 per quality-adjusted life-year. At our base case estimates, initial treatment of recurrent CDI using FMT colonoscopy was the most cost-effective strategy, with an incremental cost-effectiveness ratio of $17 016 relative to oral vancomycin. Fidaxomicin and metronidazole were both dominated by FMT colonoscopy. On sensitivity analysis, FMT colonoscopy remained the most cost-effective strategy at cure rates >88.4% and CDI recurrence rates <14.9%. Fidaxomicin required a cost <$1359 to meet our cost-effectiveness threshold. In clinical settings where FMT is not available or applicable, the preferred strategy appears to be initial treatment with oral vancomycin. In this decision analysis examining treatment strategies for recurrent CDI, we demonstrate that FMT colonoscopy is the most cost-effective initial strategy for management of recurrent CDI.

  2. Appropriateness of indication and diagnostic yield of colonoscopy: first report based on the 2000 guidelines of the American Society for Gastrointestinal Endoscopy.

    PubMed

    Siddique, Iqbal; Mohan, Krishna; Hasan, Fuad; Memon, Anjum; Patty, Istvan; Al-Nakib, Basil

    2005-11-28

    To assess the appropriateness of referrals and to determine the diagnostic yield of colonoscopy according to the 2000 guidelines of the American Society for Gastrointestinal Endoscopy (ASGE). A total of 736 consecutive patients (415 males, 321 females; mean age 43.6+/-16.6 years) undergoing colonoscopy during October 2001-March 2002 were prospectively enrolled in the study. The 2000 ASGE guidelines were used to assess the appropriateness of the indications for the procedure. Diagnostic yield was defined as the ratio between significant findings detected on colonoscopy and the total number of procedures performed for that indication. The large majority (64%) of patients had colonoscopy for an indication that was considered "generally indicated", it was "generally not indicated" for 20%, and it was "not listed" for 16% in the guidelines. The diagnostic yield of colonoscopy was highest for the "generally indicated" (38%) followed by "not listed" (13%) and "generally not indicated" (5%) categories. In the multivariable analysis, the diagnostic yield was independently associated with the appropriateness of indication that was "generally indicated" (odds ratio=12.3) and referrals by gastroenterologist (odds ratio =1.9). There is a high likelihood of inappropriate referrals for colonoscopy in an open-access endoscopy system. The diagnostic yield of the procedure is dependent on the appropriateness of indication and referring physician's specialty. Certain indications "not listed" in the guidelines have an intermediate diagnostic yield and further studies are required to evaluate whether they should be included in future revisions of the ASGE guidelines.

  3. Cost-effectiveness of computed tomography colonography in colorectal cancer screening: a systematic review.

    PubMed

    Hanly, Paul; Skally, Mairead; Fenlon, Helen; Sharp, Linda

    2012-10-01

    The European Code Against Cancer recommends individuals aged ≥ 50 should participate in colorectal cancer screening. CT-colonography (CTC) is one of several screening tests available. We systematically reviewed evidence on, and identified key factors influencing, cost-effectiveness of CTC screening. PubMed, Medline, and the Cochrane library were searched for cost-effectiveness or cost-utility analyses of CTC-based screening, published in English, January 1999 to July 2010. Data was abstracted on setting, model type and horizon, screening scenario(s), comparator(s), participants, uptake, CTC performance and cost, effectiveness, ICERs, and whether extra-colonic findings and medical complications were considered. Sixteen studies were identified from the United States (n = 11), Canada (n = 2), and France, Italy, and the United Kingdom (1 each). Markov state-transition (n = 14) or microsimulation (n = 2) models were used. Eleven considered direct medical costs only; five included indirect costs. Fourteen compared CTC with no screening; fourteen compared CTC with colonoscopy-based screening; fewer compared CTC with sigmoidoscopy (8) or fecal tests (4). Outcomes assessed were life-years gained/saved (13), QALYs (2), or both (1). Three considered extra-colonic findings; seven considered complications. CTC appeared cost-effective versus no screening and, in general, flexible sigmoidoscopy and fecal occult blood testing. Results were mixed comparing CTC to colonoscopy. Parameters most influencing cost-effectiveness included: CTC costs, screening uptake, threshold for polyp referral, and extra-colonic findings. Evidence on cost-effectiveness of CTC screening is heterogeneous, due largely to between-study differences in comparators and parameter values. Future studies should: compare CTC with currently favored tests, especially fecal immunochemical tests; consider extra-colonic findings; and conduct comprehensive sensitivity analyses.

  4. Population of 224 realistic human subject-based computational breast phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, David W.; Wells, Jered R., E-mail: jered.wells@duke.edu; Sturgeon, Gregory M.

    Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was thenmore » applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range of breast types, volumes, densities, and parenchymal patterns.« less

  5. Population of 224 realistic human subject-based computational breast phantoms

    PubMed Central

    Erickson, David W.; Wells, Jered R.; Sturgeon, Gregory M.; Dobbins, James T.; Segars, W. Paul; Lo, Joseph Y.

    2016-01-01

    Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was then applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range of breast types, volumes, densities, and parenchymal patterns. PMID:26745896

  6. Acceptability of a Salon-Based Intervention to Promote Colonoscopy Screening among African American Women

    ERIC Educational Resources Information Center

    Floyd, Tiffany D.; DuHamel, Katherine N.; Rao, Jessica; Shuk, Elyse; Jandorf, Lina

    2017-01-01

    African American women have the highest colorectal cancer incidence and mortality rates among women of any race/ethnicity in the United States. Colonoscopy screening is an efficacious procedure for the prevention and early detection of colorectal cancer, making it a promising tool in the effort to eliminate colorectal cancer disparities. Toward…

  7. Applicability of three-dimensional imaging techniques in fetal medicine*

    PubMed Central

    Werner Júnior, Heron; dos Santos, Jorge Lopes; Belmonte, Simone; Ribeiro, Gerson; Daltro, Pedro; Gasparetto, Emerson Leandro; Marchiori, Edson

    2016-01-01

    Objective To generate physical models of fetuses from images obtained with three-dimensional ultrasound (3D-US), magnetic resonance imaging (MRI), and, occasionally, computed tomography (CT), in order to guide additive manufacturing technology. Materials and Methods We used 3D-US images of 31 pregnant women, including 5 who were carrying twins. If abnormalities were detected by 3D-US, both MRI and in some cases CT scans were then immediately performed. The images were then exported to a workstation in DICOM format. A single observer performed slice-by-slice manual segmentation using a digital high resolution screen. Virtual 3D models were obtained from software that converts medical images into numerical models. Those models were then generated in physical form through the use of additive manufacturing techniques. Results Physical models based upon 3D-US, MRI, and CT images were successfully generated. The postnatal appearance of either the aborted fetus or the neonate closely resembled the physical models, particularly in cases of malformations. Conclusion The combined use of 3D-US, MRI, and CT could help improve our understanding of fetal anatomy. These three screening modalities can be used for educational purposes and as tools to enable parents to visualize their unborn baby. The images can be segmented and then applied, separately or jointly, in order to construct virtual and physical 3D models. PMID:27818540

  8. [Anorectal Malignant Melanoma Is a Very Rare Disease and Has a Poor Prognosis].

    PubMed

    Yoshida, Yuta; Noura, Shingo; Matsumura, Tae; Hirota, Masaki; Shuto, Takashi; Muratsu, Arisa; Yasuyama, Harunobu; Takata, Akihiro; Koga, Chikato; Kameda, Chizu; Murakami, Masahiro; Kawabata, Ryohei; Shimizu, Junzo; Miwa, Hideaki; Hasegawa, Junichi

    2017-11-01

    We performed abdomino-perineal-resection(APR)on 2 cases of anorectal malignant melanoma. The first case was a 70- year-old woman suffering from bloody stool. Colonoscopy showed a black tumor in the rectum. Biopsy revealed a malignant melanoma. A CT scan showed multiple lung metastases and liver metastasis. She underwent surgery for the purpose of bleeding control, but died shortly thereafter because her liver and lung metastases had worsened. The second case was a 43- years-old man suffering from bloody stool. He had a black type 3 tumor in the rectum. A biopsy revealed malignant melanoma. A CT scan showed lateral lymph node swelling. He underwent APR with right side-lateral dissection. An established treatment for anorectal malignant melanoma has not been agreed upon and it is controversial. We experienced 2 cases that underwent surgery and we report them along with relevant information from the literature.

  9. A case of pneumatosis intestinalis during neoadjuvant chemotherapy with cisplatin and 5-fluorouracil for esophageal cancer†.

    PubMed

    Kouzu, Keita; Tsujimoto, Hironori; Hiraki, Shuichi; Takahata, Risa; Yaguchi, Yoshihisa; Kumano, Isao; Horiguchi, Hiroyuki; Nomura, Shinsuke; Nagata, Ken; Harada, Manabu; Nagata, Hiromi; Sugihara, Takao; Ishibashi, Yusuke; Itazaki, Yujiro; Tsuchiya, Satoshi; Aosasa, Suefumi; Hase, Kazuo; Yamamoto, Junji; Ueno, Hideki

    2017-11-01

    Pneumatosis intestinalis (PI) is a relatively rare disease. A 70-year-old man with stage II squamous cell carcinoma of the middle thoracic esophagus was administered cisplatin plus 5-fluorouracil (CF) therapy as neoadjuvant chemotherapy. On Day 14 of the first course of CF therapy, he complained of acute abdominal pain. Computed tomography (CT) revealed PI of the entire colon and a small air bubble in the mesentery. A colonoscopy revealed that there was no finding suggestive of ischemia. Because there was no sign of peritoneal irritation, conservative treatment was selected. On Day 7 after PI diagnosis, CT indicated the disappearance of PI. The patient underwent a radical esophagectomy. Intraoperative laparoscopic findings showed the serosa of the colon to be intact. The patient was discharged without any complications. It is important to take into account that CF therapy may cause PI and that PI can be treated conservatively.

  10. The virtual craniofacial patient: 3D jaw modeling and animation.

    PubMed

    Enciso, Reyes; Memon, Ahmed; Fidaleo, Douglas A; Neumann, Ulrich; Mah, James

    2003-01-01

    In this paper, we present new developments in the area of 3D human jaw modeling and animation. CT (Computed Tomography) scans have traditionally been used to evaluate patients with dental implants, assess tumors, cysts, fractures and surgical procedures. More recently this data has been utilized to generate models. Researchers have reported semi-automatic techniques to segment and model the human jaw from CT images and manually segment the jaw from MRI images. Recently opto-electronic and ultrasonic-based systems (JMA from Zebris) have been developed to record mandibular position and movement. In this research project we introduce: (1) automatic patient-specific three-dimensional jaw modeling from CT data and (2) three-dimensional jaw motion simulation using jaw tracking data from the JMA system (Zebris).

  11. USING A MULTIFACETED APPROACH TO IMPROVE THE FOLLOW-UP OF POSITIVE FECAL OCCULT BLOOD TEST RESULTS

    PubMed Central

    Singh, Hardeep; Kadiyala, Himabindu; Bhagwath, Gayathri; Shethia, Anila; El-Serag, Hashem; Walder, Annette; Velez, Maria; Petersen, Laura A.

    2010-01-01

    Background Inadequate follow-up of abnormal fecal occult blood test (FOBT) results occurs in several types of practice settings. Our institution implemented multifaceted quality improvement (QI) activities in 2004–2005 to improve follow-up of FOBT positive results. Activities addressed pre-colonoscopy referral processes and system-level factors such as electronic communication and provider education and feedback. We evaluated their effects on timeliness and appropriateness of positive FOBT follow-up and identified factors that affect colonoscopy performance. Methods Retrospective electronic medical record (EMR) review was used to determine outcomes pre- and post-QI activities in a multi-specialty ambulatory clinic of a tertiary care Veterans Affairs facility and its affiliated satellite clinics. From 1869 FOBT positive cases, 800 were randomly selected from time periods before and after QI activities. Two reviewers used a pretested standardized data collection form to determine whether colonoscopy was appropriate or indicated based on pre-determined criteria and if so, the timeliness of colonoscopy referral and performance pre- and post-QI activities. Results In cases where a colonoscopy was indicated, the proportion of patients who received a timely colonoscopy referral and performance were significantly higher post implementation (60.5% vs. 31.7%, p<0.0001 and 11.4% vs. 3.4%, p =0.0005 respectively). A significant decrease also resulted in median times to referral and performance (6 vs. 19 days p<0.0001 and 96.5 vs. 190 days p<0.0001 respectively) and in the proportion of positive FOBT test results that had received no follow-up by the time of chart review (24.3%vs. 35.9%; p=0.0045). Significant predictors of absence of the performance of an indicated colonoscopy included performance of a non-colonoscopy procedure such as barium enema or flexible sigmoidoscopy (OR=16.9; 95% CI 1.9–145.1), patient non-adherence (OR=33.9; 95% CI 17.3–66.6), not providing an appropriate provisional diagnosis on the consultation (OR= 17.9; 95% CI 11.3–28.1) and gastroenterology service not rescheduling colonoscopies after an initial cancellation (OR= 11.0; 95% CI 5.1–23.7) Conclusions Multifaceted QI activities improved rates of timely colonoscopy referral and performance in an EMR system. However, colonoscopy was not indicated in over one third of patients with positive FOBTs, raising concerns about current screening practices and the appropriate denominator used for performance measurement standards related to colon cancer screening. PMID:19293786

  12. Application of two segmentation protocols during the processing of virtual images in rapid prototyping: ex vivo study with human dry mandibles.

    PubMed

    Ferraz, Eduardo Gomes; Andrade, Lucio Costa Safira; dos Santos, Aline Rode; Torregrossa, Vinicius Rabelo; Rubira-Bullen, Izabel Regina Fischer; Sarmento, Viviane Almeida

    2013-12-01

    The aim of this study was to evaluate the accuracy of virtual three-dimensional (3D) reconstructions of human dry mandibles, produced from two segmentation protocols ("outline only" and "all-boundary lines"). Twenty virtual three-dimensional (3D) images were built from computed tomography exam (CT) of 10 dry mandibles, in which linear measurements between anatomical landmarks were obtained and compared to an error probability of 5 %. The results showed no statistically significant difference among the dry mandibles and the virtual 3D reconstructions produced from segmentation protocols tested (p = 0,24). During the designing of a virtual 3D reconstruction, both "outline only" and "all-boundary lines" segmentation protocols can be used. Virtual processing of CT images is the most complex stage during the manufacture of the biomodel. Establishing a better protocol during this phase allows the construction of a biomodel with characteristics that are closer to the original anatomical structures. This is essential to ensure a correct preoperative planning and a suitable treatment.

  13. Feasibility of a colon capsule overnight procedure followed by colonoscopy.

    PubMed

    Brechmann, T; Schmiegel, W; Klute, L; Rösch, T; Pox, C

    2016-02-01

    Due to limited acceptance of colonoscopy as diagnostic and screening test alternatives are warranted. Colon capsule endoscopy (CCE) has been shown to be a possible filter test, but because of logistical issues a second bowel preparation is usually required, if consecutive colonoscopy is needed. We therefore evaluated the feasibility of a single bowel preparation for both overnight CCE and (therapeutical) colonoscopy thereafter. Patients from two university hospitals referred to undergo colonoscopy were prospectively included in a dual centre feasibility study. A polyethylene glycol (PEG) based bowel preparation-schedule with ingestion of a colon capsule endoscopy (CCE) at 10pm and subsequent colonoscopy at about 12am on the next day was investigated. The first generation PillCam colon capsule was used with 4 different preparation protocols containing several prokinetics in different compositions (i. e. metoclopramide, erythromycin, sennosoides). The main endpoint was the proportion of patients who completed both CCE and colonoscopy; secondary endpoints were capsule transit times, amount of colon seen on CCE, bowel cleanliness, sensitivity and specifity of CCE and patients' acceptance. 50 patients between 18 and 75 years were included. The sequence of overnight colon capsule endoscopy and colonoscopy was successfully completed in all but one (one refused colonoscopy). The capsule was excreted during recording time in 86 % of examinations, visualization of the complete colon was possible in 60 %, but adequate colon preparation was achieved in only 45 % irrespective of the regimen used. The preparation regimen consisting of a PEG-solution, erythromycin as prokinetic drug followed by PEG-solution as boost showed the largest proportion of adequate preparations. Overall sensitivity and specificity of CCE for polyps of any size were 65 % and 76 %, respectively. 26 of 30 patients (86.7 %) returned the subjective assessment questionnaire. 23 patients (88 %) reported mild to no discomfort or embarrassment during CCE, whereas 15 patients (58 %) did during the preparation procedure. Drinking the purgative solution was the most inconvenient step in 84 % of cases, drinking the boosts during CCE the second inconvenient step (60 %). Overnight CCE-procedure followed by direct capsule-reading is feasible and safe and might avoid repetitive bowel preparation for subsequent colonoscopy. The bowel preparation needs to be improved. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Virtual non-contrast in second-generation, dual-energy computed tomography: reliability of attenuation values.

    PubMed

    Toepker, Michael; Moritz, Thomas; Krauss, Bernhard; Weber, Michael; Euller, Gordon; Mang, Thomas; Wolf, Florian; Herold, Christian J; Ringl, Helmut

    2012-03-01

    To evaluate the reliability of attenuation values in virtual non-contrast images (VNC) reconstructed from contrast-enhanced, dual-energy scans performed on a second-generation dual-energy CT scanner, compared to single-energy, non-contrast images (TNC). Sixteen phantoms containing a mixture of contrast agent and water at different attenuations (0-1400 HU) were investigated on a Definition Flash-CT scanner using a single-energy scan at 120 kV and a DE-CT protocol (100 kV/SN140 kV). For clinical assessment, 86 patients who received a dual-phase CT, containing an unenhanced single-energy scan at 120 kV and a contrast enhanced (110 ml Iomeron 400 mg/ml; 4 ml/s) DE-CT (100 kV/SN140 kV) in an arterial (n=43) or a venous phase, were retrospectively analyzed. Mean attenuation was measured within regions of interest of the phantoms and in different tissue types of the patients within the corresponding VNC and TNC images. Paired t-tests and Pearson correlation were used for statistical analysis. For all phantoms, mean attenuation in VNC was 5.3±18.4 HU, with respect to water. In 86 patients overall, 2637 regions were measured in TNC and VNC images, with a mean difference between TNC and VNC of -3.6±8.3 HU. In 91.5% (n=2412) of all cases, absolute differences between TNC and VNC were under 15HU, and, in 75.3% (n=1986), differences were under 10 HU. Second-generation dual-energy CT based VNC images provide attenuation values close to those of TNC. To avoid possible outliers multiple measurements are recommended especially for measurements in the spleen, the mesenteric fat, and the aorta. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. Software platform for simulation of a prototype proton CT scanner.

    PubMed

    Giacometti, Valentina; Bashkirov, Vladimir A; Piersimoni, Pierluigi; Guatelli, Susanna; Plautz, Tia E; Sadrozinski, Hartmut F-W; Johnson, Robert P; Zatserklyaniy, Andriy; Tessonnier, Thomas; Parodi, Katia; Rosenfeld, Anatoly B; Schulte, Reinhard W

    2017-03-01

    Proton computed tomography (pCT) is a promising imaging technique to substitute or at least complement x-ray CT for more accurate proton therapy treatment planning as it allows calculating directly proton relative stopping power from proton energy loss measurements. A proton CT scanner with a silicon-based particle tracking system and a five-stage scintillating energy detector has been completed. In parallel a modular software platform was developed to characterize the performance of the proposed pCT. The modular pCT software platform consists of (1) a Geant4-based simulation modeling the Loma Linda proton therapy beam line and the prototype proton CT scanner, (2) water equivalent path length (WEPL) calibration of the scintillating energy detector, and (3) image reconstruction algorithm for the reconstruction of the relative stopping power (RSP) of the scanned object. In this work, each component of the modular pCT software platform is described and validated with respect to experimental data and benchmarked against theoretical predictions. In particular, the RSP reconstruction was validated with both experimental scans, water column measurements, and theoretical calculations. The results show that the pCT software platform accurately reproduces the performance of the existing prototype pCT scanner with a RSP agreement between experimental and simulated values to better than 1.5%. The validated platform is a versatile tool for clinical proton CT performance and application studies in a virtual setting. The platform is flexible and can be modified to simulate not yet existing versions of pCT scanners and higher proton energies than those currently clinically available. © 2017 American Association of Physicists in Medicine.

  16. Virtual animation of victim-specific 3D models obtained from CT scans for forensic reconstructions: Living and dead subjects.

    PubMed

    Villa, C; Olsen, K B; Hansen, S H

    2017-09-01

    Post-mortem CT scanning (PMCT) has been introduced at several forensic medical institutions many years ago and has proved to be a useful tool. 3D models of bones, skin, internal organs and bullet paths can rapidly be generated using post-processing software. These 3D models reflect the individual physiognomics and can be used to create whole-body 3D virtual animations. In such way, virtual reconstructions of the probable ante-mortem postures of victims can be constructed and contribute to understand the sequence of events. This procedure is demonstrated in two victims of gunshot injuries. Case #1 was a man showing three perforating gunshot wounds, who died due to the injuries of the incident. Whole-body PMCT was performed and 3D reconstructions of bones, relevant internal organs and bullet paths were generated. Using 3ds Max software and a human anatomy 3D model, a virtual animated body was built and probable ante-mortem postures visualized. Case #2 was a man presenting three perforating gunshot wounds, who survived the incident: one in the left arm and two in the thorax. Only CT scans of the thorax, abdomen and the injured arm were provided by the hospital. Therefore, a whole-body 3D model reflecting the anatomical proportions of the patient was made combining the actual bones of the victim with those obtained from the human anatomy 3D model. The resulted 3D model was used for the animation process. Several probable postures were also visualized in this case. It has be shown that in Case #1 the lesions and the bullet path were not consistent with an upright standing position; instead, the victim was slightly bent forward, i.e. he was sitting or running when he was shot. In Case #2, one of the bullets could have passed through the arm and continued into the thorax. In conclusion, specialized 3D modelling and animation techniques allow for the reconstruction of ante-mortem postures based on both PMCT and clinical CT. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Is Travel Time to Colonoscopy Associated With Late-Stage Colorectal Cancer Among Medicare Beneficiaries in Iowa?

    PubMed

    Charlton, Mary E; Matthews, Kevin A; Gaglioti, Anne; Bay, Camden; McDowell, Bradley D; Ward, Marcia M; Levy, Barcey T

    2016-09-01

    Colorectal cancer (CRC) screening has been shown to decrease the incidence of late-stage colorectal cancer, yet a substantial proportion of Americans do not receive screening. Those in rural areas may face barriers to colonoscopy services based on travel time, and previous studies have demonstrated lower screening among rural residents. Our purpose was to assess factors associated with late-stage CRC, and specifically to determine if longer travel time to colonoscopy was associated with late-stage CRC among an insured population in Iowa. SEER-Medicare data were used to identify individuals ages 65 to 84 years old diagnosed with CRC in Iowa from 2002 to 2009. The distance between the centroid of the ZIP code of residence and the ZIP code of colonoscopy was computed for each individual who had continuous Medicare fee-for-service coverage for a 3- to 4-month period prior to diagnosis, and a professional claim for colonoscopy within that time frame. Demographic characteristics and travel times were compared between those diagnosed with early- versus late-stage CRC. Also, demographic differences between those who had colonoscopy claims identified within 3-4 months prior to diagnosis (81%) were compared to patients with no colonoscopy claims identified (19%). A total of 5,792 subjects met inclusion criteria; 31% were diagnosed with early-stage versus 69% with late-stage CRC. Those divorced or widowed (vs married) were more likely to be diagnosed with late-stage CRC (OR: 1.20, 95% CI: 1.06-1.37). Travel time was not associated with diagnosis of late-stage CRC. Among a Medicare-insured population, there was no relationship between travel time to colonoscopy and disease stage at diagnosis. It is likely that factors other than distance to colonoscopy present more pertinent barriers to screening in this insured population. Additional research should be done to determine reasons for nonadherence to screening among those with access to CRC screening services, given that over two-thirds of these insured individuals were diagnosed with late-stage CRC. © 2015 National Rural Health Association.

  18. SU-F-J-186: Enabling Adaptive IMPT with CBCT-Based Dose Recalculation for H&N and Prostate Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurz, C; LMU Munich, Munich; Park, Y

    2016-06-15

    Purpose: To enable adaptive intensity modulated proton therapy for sites sensitive to inter-fractional changes on the basis of accurate CBCT-based proton dose calculations. To this aim two CBCT intensity correction methods are considered: planning CT (pCT) to CBCT DIR and projection correction based on pCT DIR prior. Methods: 3 H&N and 3 prostate cancer patients with CBCT images and corresponding projections were used in this study, in addition to pCT and re-planning CT (rpCT) images (H&N only). A virtual CT (vCT) was generated by pCT to CBCT DIR. In a second approach, the vCT was used as prior for scattermore » correction of the CBCT projections to yield a CBCTcor image. BEV 2D range maps of SFUD IMPT plans were compared. For the prostate cases, the geometric accuracy of the vCT was also evaluated by contour comparison to physician delineation of the CBCTcor and original CBCT. Results: SFUD dose calculations on vCT and CBCTcor were found to be within 3mm for 97% to 99% of 2D range maps. Median range differences compared to rpCT were below 0.5mm. Analysis showed that the DIR-based vCT approach exhibits inaccuracies in the pelvic region due to the very low soft-tissue contrast in the CBCT. The CBCTcor approach yielded results closer to the original CBCT in terms of DICE coefficients than the vCT (median 0.91 vs 0.81) for targets and OARs. In general, the CBCTcor approach was less affected by inaccuracies of the DIR used during the generation of the vCT prior. Conclusion: Both techniques yield 3D CBCT images with intensities equivalent to diagnostic CT and appear suitable for IMPT dose calculation for most sites. For H&N cases, no considerable differences between the two techniques were found, while improved results of the CBCTcor were observed for pelvic cases due to the reduced sensitivity to registration inaccuracies. Deutsche Forschungsgemeinschaft (MAP); Bundesministerium fur Bildung und Forschung (01IB13001)« less

  19. Adaptive learning compressive tracking based on Markov location prediction

    NASA Astrophysics Data System (ADS)

    Zhou, Xingyu; Fu, Dongmei; Yang, Tao; Shi, Yanan

    2017-03-01

    Object tracking is an interdisciplinary research topic in image processing, pattern recognition, and computer vision which has theoretical and practical application value in video surveillance, virtual reality, and automatic navigation. Compressive tracking (CT) has many advantages, such as efficiency and accuracy. However, when there are object occlusion, abrupt motion and blur, similar objects, and scale changing, the CT has the problem of tracking drift. We propose the Markov object location prediction to get the initial position of the object. Then CT is used to locate the object accurately, and the classifier parameter adaptive updating strategy is given based on the confidence map. At the same time according to the object location, extract the scale features, which is able to deal with object scale variations effectively. Experimental results show that the proposed algorithm has better tracking accuracy and robustness than current advanced algorithms and achieves real-time performance.

  20. Virtual reality exposure versus cognitive restructuring for treatment of public speaking anxiety: a pilot study.

    PubMed

    Wallach, Helene S; Safir, Marilyn P; Bar-Zvi, Margalit

    2011-01-01

    To determine the utility of Virtual Reality Exposure Therapy (VRE) in comparison with Cognitive Therapy (CT ) and with Cognitive-Behavior Therapy (CBT). Subjects suffering from public speaking anxiety (PSA) were randomly allocated to VRE and CT , and received 12 therapy sessions, employing standardized treatment manuals. Outcome (questionnaires, observer and self ratings of a behavioral task) was compared to results of subjects in a previous study CBT and Wait List Controls who were not significantly different on demographic data. CT was not superior to VRE on cognitive measures, but was superior to VRE on one behavioral measure (LSAS fear). VRE was superior to CT on one behavioral measure (fear reduction on a behavioral task). No differences were found between either CT , or VRE, and CBT and all were superior to WL. Subject group was small and homogeneous. It appeared advisable to increase number of therapy sessions. VRE and CT proved to be equally effective to CBT in reducing PSA relative to a control group, with minimal differential effects between them. Therefore, employing either one may be satisfactory and sufficient.

  1. Paleoradiology: advanced CT in the evaluation of nine Egyptian mummies.

    PubMed

    Hoffman, Heidi; Torres, William E; Ernst, Randy D

    2002-01-01

    Axial thin-collimation state-of-the-art spiral computed tomography (CT) was combined with sagittal and coronal reformatting, three-dimensional (3D) reconstruction, and virtual "fly-through" techniques to nondestructively study nine Egyptian mummies. These techniques provided important paleopathologic and historical information about mummification techniques, depicted anatomy in the most informative imaging plane, illustrated the soft-tissue preservation and physical appearance of mummies in superb detail, and generated an intriguing virtual tour through hollow mummified remains without harming the specimens themselves. Images generated with these methods can help archaeologists and Egyptologists understand these fascinating members of mankind and can serve as adjunct visual aids for laypersons who are interested in mummies. CT has emerged as the imaging modality of choice for the examination of Egyptian mummies due to its noninvasive cross-sectional nature and inherently superior contrast and spatial resolution. As multi-detector row CT and postprocessing tools evolve, the capabilities and applications of CT will continue to proliferate, attesting to the expanded versatility and utility of CT as a noninvasive research tool in the multidisciplinary study of Egyptian mummies. Copyright RSNA, 2002

  2. Incorporating virtual reality graphics with brain imaging for assessment of sport-related concussions.

    PubMed

    Slobounov, Semyon; Sebastianelli, Wayne; Newell, Karl M

    2011-01-01

    There is a growing concern that traditional neuropsychological (NP) testing tools are not sensitive to detecting residual brain dysfunctions in subjects suffering from mild traumatic brain injuries (MTBI). Moreover, most MTBI patients are asymptomatic based on anatomical brain imaging (CT, MRI), neurological examinations and patients' subjective reports within 10 days post-injury. Our ongoing research has documented that residual balance and visual-kinesthetic dysfunctions along with its underlying alterations of neural substrates may be detected in "asymptomatic subjects" by means of Virtual Reality (VR) graphics incorporated with brain imaging (EEG) techniques.

  3. Wavelet method for CT colonography computer-aided polyp detection.

    PubMed

    Li, Jiang; Van Uitert, Robert; Yao, Jianhua; Petrick, Nicholas; Franaszek, Marek; Huang, Adam; Summers, Ronald M

    2008-08-01

    Computed tomographic colonography (CTC) computer aided detection (CAD) is a new method to detect colon polyps. Colonic polyps are abnormal growths that may become cancerous. Detection and removal of colonic polyps, particularly larger ones, has been shown to reduce the incidence of colorectal cancer. While high sensitivities and low false positive rates are consistently achieved for the detection of polyps sized 1 cm or larger, lower sensitivities and higher false positive rates occur when the goal of CAD is to identify "medium"-sized polyps, 6-9 mm in diameter. Such medium-sized polyps may be important for clinical patient management. We have developed a wavelet-based postprocessor to reduce false positives for this polyp size range. We applied the wavelet-based postprocessor to CTC CAD findings from 44 patients in whom 45 polyps with sizes of 6-9 mm were found at segmentally unblinded optical colonoscopy and visible on retrospective review of the CT colonography images. Prior to the application of the wavelet-based postprocessor, the CTC CAD system detected 33 of the polyps (sensitivity 73.33%) with 12.4 false positives per patient, a sensitivity comparable to that of expert radiologists. Fourfold cross validation with 5000 bootstraps showed that the wavelet-based postprocessor could reduce the false positives by 56.61% (p <0.001), to 5.38 per patient (95% confidence interval [4.41, 6.34]), without significant sensitivity degradation (32/45, 71.11%, 95% confidence interval [66.39%, 75.74%], p=0.1713). We conclude that this wavelet-based postprocessor can substantially reduce the false positive rate of our CTC CAD for this important polyp size range.

  4. [THE FAILURE MODES AND EFFECTS ANALYSIS FACILITATES A SAFE, TIME AND MONEY SAVING OPEN ACCESS COLONOSCOPY SERVICE].

    PubMed

    Gingold-Belfer, Rachel; Niv, Yaron; Horev, Nehama; Gross, Shuli; Sahar, Nadav; Dickman, Ram

    2017-04-01

    Failure modes and effects analysis (FMEA) is used for the identification of potential risks in health care processes. We used a specific FMEA - based form for direct referral for colonoscopy and assessed it for procedurerelated perforations. Ten experts in endoscopy evaluated and computed the entire referral process, modes of preparation for the endoscopic procedure, the endoscopic procedure itself and the discharge process. We used FMEA assessing for likelihood of occurrence, detection and severity and calculated the risk profile number (RPN) for each of the above points. According to the highest RPN results we designed a specific open access referral form and then compared the occurrence of colonic perforations (between 2010 and 2013) in patients who were referred through the open access arm (Group 1) to those who had a prior clinical consultation (non-open access, Group 2). Our experts in endoscopy (5 physicians and 5 nurses) identified 3 categories of failure modes that, on average, reached the highest RPNs. We identified 9,558 colonoscopies in group 1, and 12,567 in group 2. Perforations were identified in three patients from the open access group (1:3186, 0.03%) and in 10 from group 2 (1:1256, 0.07%) (p = 0.024). Direct referral for colonoscopy saved 9,558 pre-procedure consultations and the sum of $850,000. The FMEA tool-based specific referral form facilitates a safe, time and money saving open access colonoscopy service. Our form may be adopted by other gastroenterological clinics in Israel.

  5. Patient-specific CT dosimetry calculation: a feasibility study.

    PubMed

    Fearon, Thomas; Xie, Huchen; Cheng, Jason Y; Ning, Holly; Zhuge, Ying; Miller, Robert W

    2011-11-15

    Current estimation of radiation dose from computed tomography (CT) scans on patients has relied on the measurement of Computed Tomography Dose Index (CTDI) in standard cylindrical phantoms, and calculations based on mathematical representations of "standard man". Radiation dose to both adult and pediatric patients from a CT scan has been a concern, as noted in recent reports. The purpose of this study was to investigate the feasibility of adapting a radiation treatment planning system (RTPS) to provide patient-specific CT dosimetry. A radiation treatment planning system was modified to calculate patient-specific CT dose distributions, which can be represented by dose at specific points within an organ of interest, as well as organ dose-volumes (after image segmentation) for a GE Light Speed Ultra Plus CT scanner. The RTPS calculation algorithm is based on a semi-empirical, measured correction-based algorithm, which has been well established in the radiotherapy community. Digital representations of the physical phantoms (virtual phantom) were acquired with the GE CT scanner in axial mode. Thermoluminescent dosimeter (TLDs) measurements in pediatric anthropomorphic phantoms were utilized to validate the dose at specific points within organs of interest relative to RTPS calculations and Monte Carlo simulations of the same virtual phantoms (digital representation). Congruence of the calculated and measured point doses for the same physical anthropomorphic phantom geometry was used to verify the feasibility of the method. The RTPS algorithm can be extended to calculate the organ dose by calculating a dose distribution point-by-point for a designated volume. Electron Gamma Shower (EGSnrc) codes for radiation transport calculations developed by National Research Council of Canada (NRCC) were utilized to perform the Monte Carlo (MC) simulation. In general, the RTPS and MC dose calculations are within 10% of the TLD measurements for the infant and child chest scans. With respect to the dose comparisons for the head, the RTPS dose calculations are slightly higher (10%-20%) than the TLD measurements, while the MC results were within 10% of the TLD measurements. The advantage of the algebraic dose calculation engine of the RTPS is a substantially reduced computation time (minutes vs. days) relative to Monte Carlo calculations, as well as providing patient-specific dose estimation. It also provides the basis for a more elaborate reporting of dosimetric results, such as patient specific organ dose volumes after image segmentation.

  6. An augmented reality tool for learning spatial anatomy on mobile devices.

    PubMed

    Jain, Nishant; Youngblood, Patricia; Hasel, Matthew; Srivastava, Sakti

    2017-09-01

    Augmented Realty (AR) offers a novel method of blending virtual and real anatomy for intuitive spatial learning. Our first aim in the study was to create a prototype AR tool for mobile devices. Our second aim was to complete a technical evaluation of our prototype AR tool focused on measuring the system's ability to accurately render digital content in the real world. We imported Computed Tomography (CT) data derived virtual surface models into a 3D Unity engine environment and implemented an AR algorithm to display these on mobile devices. We investigated the accuracy of the virtual renderings by comparing a physical cube with an identical virtual cube for dimensional accuracy. Our comparative study confirms that our AR tool renders 3D virtual objects with a high level of accuracy as evidenced by the degree of similarity between measurements of the dimensions of a virtual object (a cube) and the corresponding physical object. We developed an inexpensive and user-friendly prototype AR tool for mobile devices that creates highly accurate renderings. This prototype demonstrates an intuitive, portable, and integrated interface for spatial interaction with virtual anatomical specimens. Integrating this AR tool with a library of CT derived surface models provides a platform for spatial learning in the anatomy curriculum. The segmentation methodology implemented to optimize human CT data for mobile viewing can be extended to include anatomical variations and pathologies. The ability of this inexpensive educational platform to deliver a library of interactive, 3D models to students worldwide demonstrates its utility as a supplemental teaching tool that could greatly benefit anatomical instruction. Clin. Anat. 30:736-741, 2017. © 2017Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. Appropriateness of indication and diagnostic yield of colonoscopy: First report based on the 2000 guidelines of the American Society for Gastrointestinal Endoscopy

    PubMed Central

    Siddique, Iqbal; Mohan, Krishna; Hasan, Fuad; Memon, Anjum; Patty, Istvan; Al-Nakib, Basil

    2005-01-01

    AIM: To assess the appropriateness of referrals and to determine the diagnostic yield of colonoscopy according to the 2000 guidelines of the American Society for Gastrointestinal Endoscopy (ASGE). METHODS: A total of 736 consecutive patients (415 males, 321 females; mean age 43.6±16.6 years) undergoing colonoscopy during October 2001-March 2002 were prospectively enrolled in the study. The 2000 ASGE guidelines were used to assess the appropriateness of the indications for the procedure. Diagnostic yield was defined as the ratio between significant findings detected on colonoscopy and the total number of procedures performed for that indication. RESULTS: The large majority (64%) of patients had colonoscopy for an indication that was considered “generally indicated”, it was “generally not indicated” for 20%, and it was “not listed” for 16% in the guidelines. The diagnostic yield of colonoscopy was highest for the “generally indicated” (38%) followed by “not listed” (13%) and “generally not indicated” (5%) categories. In the multivariable analysis, the diagnostic yield was independently associated with the appropriateness of indication that was “generally indicated” (odds ratio=12.3) and referrals by gastroenterologist (odds ratio =1.9). CONCLUSION: There is a high likelihood of inappropriate referrals for colonoscopy in an open-access endoscopy system. The diagnostic yield of the procedure is dependent on the appropriateness of indication and referring physician’s specialty. Certain indications “not listed” in the guidelines have an intermediate diagnostic yield and further studies are required to evaluate whether they should be included in future revisions of the ASGE guidelines. PMID:16437607

  8. Charity colonoscopy event to commemorate the 185th anniversary of Singapore General Hospital.

    PubMed

    Ng, Kheng Hong; Lim, Jit Fong; Ho, Kok Sun; Ooi, Boon Swee; Tang, Choong Leong; Eu, Kong Weng

    2008-03-01

    Colorectal cancer is now the cancer with the highest incidence in Singapore. However, the overall mortality rate is still about 50% because the majority of the patients present at a late stage of disease. A charity event of screening colonoscopy was offered to the public in conjunction with the 185th anniversary of Singapore General Hospital. The aim of this event was to raise awareness about early detection of colorectal cancer and the safety of colonoscopy. We conducted a one-off free screening event for colorectal cancer using colonoscopy. Four hundred and ninety individuals responded to a multimedia advertisement for the event. Of these, 220 individuals were selected for the screening based on National Guidelines for colorectal cancer screening and financial status. One hundred and fifty-two individuals turned up for the colonoscopy. The median age was 55 years (range, 22 to 82), with 84 males. Significant pathology was found in 33% of the individuals (n = 51). Colorectal polyps were detected in 34 individuals (22%). A total of 45 polyps were removed, with 20 hyperplastic polyps and 25 adenomas. Eight out of 25 adenomas were located proximal to the splenic flexure. Rectal cancer was diagnosed in 1 individual (0.6%). One individual had a large dysplastic rectosigmoid ulcer and refused further intervention. There were no significant complications from any of the colonoscopies. Colonoscopy is an invaluable screening modality as it has a high pick-up rate for colorectal polyp and cancer in an asymptomatic population. It is also proven to be safe in our study. It has the added advantage over flexible sigmoidoscopy of detecting a significant number of proximal lesions. Also, therapeutic polypectomy can be performed in the same setting.

  9. Colonoscopy-based colorectal cancer modeling in mice with CRISPR-Cas9 genome editing and organoid transplantation.

    PubMed

    Roper, Jatin; Tammela, Tuomas; Akkad, Adam; Almeqdadi, Mohammad; Santos, Sebastian B; Jacks, Tyler; Yilmaz, Ömer H

    2018-02-01

    Most genetically engineered mouse models (GEMMs) of colorectal cancer are limited by tumor formation in the small intestine, a high tumor burden that limits metastasis, and the need to generate and cross mutant mice. Cell line or organoid transplantation models generally produce tumors in ectopic locations-such as the subcutaneous space, kidney capsule, or cecal wall-that do not reflect the native stromal environment of the colon mucosa. Here, we describe detailed protocols to rapidly and efficiently induce site-directed tumors in the distal colon of mice that are based on colonoscopy-guided mucosal injection. These techniques can be adapted to deliver viral vectors carrying Cre recombinase, CRISPR-Cas9 components, CRISPR-engineered mouse tumor organoids, or human cancer organoids to mice to model the adenoma-carcinoma-metastasis sequence of tumor progression. The colonoscopy injection procedure takes ∼15 min, including preparation. In our experience, anyone with reasonable hand-eye coordination can become proficient with mouse colonoscopy and mucosal injection with a few hours of practice. These approaches are ideal for a wide range of applications, including assessment of gene function in tumorigenesis, examination of tumor-stroma interactions, studies of cancer metastasis, and translational research with patient-derived cancers.

  10. 2017 WSES guidelines for the management of iatrogenic colonoscopy perforation.

    PubMed

    de'Angelis, Nicola; Di Saverio, Salomone; Chiara, Osvaldo; Sartelli, Massimo; Martínez-Pérez, Aleix; Patrizi, Franca; Weber, Dieter G; Ansaloni, Luca; Biffl, Walter; Ben-Ishay, Offir; Bala, Miklosh; Brunetti, Francesco; Gaiani, Federica; Abdalla, Solafah; Amiot, Aurelien; Bahouth, Hany; Bianchi, Giorgio; Casanova, Daniel; Coccolini, Federico; Coimbra, Raul; de'Angelis, Gian Luigi; De Simone, Belinda; Fraga, Gustavo P; Genova, Pietro; Ivatury, Rao; Kashuk, Jeffry L; Kirkpatrick, Andrew W; Le Baleur, Yann; Machado, Fernando; Machain, Gustavo M; Maier, Ronald V; Chichom-Mefire, Alain; Memeo, Riccardo; Mesquita, Carlos; Salamea Molina, Juan Carlos; Mutignani, Massimiliano; Manzano-Núñez, Ramiro; Ordoñez, Carlos; Peitzman, Andrew B; Pereira, Bruno M; Picetti, Edoardo; Pisano, Michele; Puyana, Juan Carlos; Rizoli, Sandro; Siddiqui, Mohammed; Sobhani, Iradj; Ten Broek, Richard P; Zorcolo, Luigi; Carra, Maria Clotilde; Kluger, Yoram; Catena, Fausto

    2018-01-01

    Iatrogenic colonoscopy perforation (ICP) is a severe complication that can occur during both diagnostic and therapeutic procedures. Although 45-60% of ICPs are diagnosed by the endoscopist while performing the colonoscopy, many ICPs are not immediately recognized but are instead suspected on the basis of clinical signs and symptoms that occur after the endoscopic procedure. There are three main therapeutic options for ICPs: endoscopic repair, conservative therapy, and surgery. The therapeutic approach must vary based on the setting of the diagnosis (intra- or post-colonoscopy), the type of ICP, the characteristics and general status of the patient, the operator's level of experience, and surgical device availability. Although ICPs have been the focus of numerous publications, no guidelines have been created to standardize the management of ICPs. The aim of this article is to present the World Society of Emergency Surgery (WSES) guidelines for the management of ICP, which are intended to be used as a tool to promote global standards of care in case of ICP. These guidelines are not meant to substitute providers' clinical judgment for individual patients, and they may need to be modified based on the medical team's level of experience and the availability of local resources.

  11. Narrative message targets within the decision-making process to undergo screening colonoscopy among Latinos: a qualitative study.

    PubMed

    Hennelly, Marie Oliva; Sly, Jamilia R; Villagra, Cristina; Jandorf, Lina

    2015-06-01

    Colorectal cancer (CRC) is a preventable yet leading cause of cancer mortality among Latinos in the USA. Cultural targeting and narrative messaging are two strategies to increase the low screening colonoscopy rates among Latinos. This study identifies key messages for educational interventions aiming to increase screening colonoscopy used among Latinos and proposes a model to understand the relationship between factors involved in colonoscopy decision-making. Individual in-depth interviews were conducted with 12 Latino participants primarily of Puerto Rican descent on the topics of CRC knowledge, barriers and facilitators to colonoscopy use, and the use of narrative in colorectal health messaging. Knowledge about colorectal anatomy and the anesthesia component of colonoscopy procedure is low. Fear of procedure-related pain and fear of treatment-related burden following a cancer diagnosis are significant barriers to colonoscopy. Fear of disease-related suffering and death following a cancer diagnosis and fear of regret are strong facilitators and can be augmented by cancer narratives. Storytelling is commonly used in Latino culture and is an acceptable method to educate the Latino community about CRC screening via colonoscopy. Machismo is a unique barrier to colonoscopy for Latino men via homophobia and reluctance to seek healthcare. A preliminary model to understand factors in colonoscopy decision-making among Latinos is presented. Counseling practices and educational interventions that use culturally targeted narrative health messaging to mediate fears and increase colonoscopy knowledge may increase screening colonoscopy use among Latinos.

  12. Perceived Threat and Internet Use Predict Intentions to Get Bowel Cancer Screening (Colonoscopy): Longitudinal Questionnaire Study

    PubMed Central

    Grapendorf, Johannes; Greving, Hannah; Sassenberg, Kai

    2018-01-01

    Background Many people use the Internet for health-related information search, which is known to help regulate their emotional state. However, not much is known yet about how Web-based information search together with negative emotional states (ie, threat of cancer diagnosis) relate to preventive medical treatment decisions (ie, colonoscopy intentions). Objective The aim of this study was to investigate how frequency of health-related Internet use together with perceived threat of a possible (bowel) cancer diagnosis influences intentions to get a colonoscopy. Previous research has shown that people who experience threat preferentially process positive information in an attempt to downregulate the aversive emotional state. The Internet can facilitate this regulatory strategy through allowing self-directed, unrestricted, and thus biased information search. In the context of threat regarding a possible bowel cancer diagnosis, feelings of threat can still be effectively reduced through cancer screening (ie, colonoscopy). We, therefore, predict that in that particular context, feelings of threat should be related to stronger colonoscopy intentions, and that this relationship should be enhanced for people who use the Internet often. Methods A longitudinal questionnaire study was conducted among healthy participants who were approaching or just entering the bowel cancer risk group (aged 45-55 years). Perceived threat of a possible (bowel) cancer diagnosis, frequency of health-related Internet use, and intentions to have a colonoscopy were assessed at 2 time points (6-month time lag between the 2 measurement points T1 and T2). Multiple regression analyses were conducted to test whether threat and Internet use at T1 together predicted colonoscopy intentions at T2. Results In line with our predictions, we found that the threat of a possible (bowel) cancer diagnosis interacted with the frequency of Internet use (both T1) to predict colonoscopy intentions (T2; B=.23, standard error [SE]=0.09, P=.01). For people who used the Internet relatively often (+1 SD), the positive relationship between threat and colonoscopy intentions was significantly stronger (B=.56, SE=0.15, P<.001) compared with participants who used the Internet less often (−1 SD; B=.17, SE=0.09, P=.07). This relationship was unique to Web-based (vs other types of) information search and independent of risk factors (eg, body mass index [BMI] and smoking). Conclusions The results of this study suggest that health-related Internet use can facilitate emotion-regulatory processes. People who feel threatened by a possible (bowel) cancer diagnosis reported stronger colonoscopy intentions, especially when they used the Internet often. We propose that this is because people who experience threat are more likely to search for and process information that allows them to downregulate their aversive emotional state. In the present case of (bowel) cancer prevention, the most effective way to reduce threat is to get screened. PMID:29415872

  13. Cost-effectiveness of Competing Strategies for Management of Recurrent Clostridium difficile Infection: A Decision Analysis

    PubMed Central

    Konijeti, Gauree G.; Sauk, Jenny; Shrime, Mark G.; Gupta, Meera; Ananthakrishnan, Ashwin N.

    2014-01-01

    Background. Clostridium difficile infection (CDI) is an important cause of morbidity and healthcare costs, and is characterized by high rates of disease recurrence. The cost-effectiveness of newer treatments for recurrent CDI has not been examined, yet would be important to inform clinical practice. The aim of this study was to analyze the cost effectiveness of competing strategies for recurrent CDI. Methods. We constructed a decision-analytic model comparing 4 treatment strategies for first-line treatment of recurrent CDI in a population with a median age of 65 years: metronidazole, vancomycin, fidaxomicin, and fecal microbiota transplant (FMT). We modeled up to 2 additional recurrences following the initial recurrence. We assumed FMT delivery via colonoscopy as our base case, but conducted sensitivity analyses based on different modes of delivery. Willingness-to-pay threshold was set at $50 000 per quality-adjusted life-year. Results. At our base case estimates, initial treatment of recurrent CDI using FMT colonoscopy was the most cost-effective strategy, with an incremental cost-effectiveness ratio of $17 016 relative to oral vancomycin. Fidaxomicin and metronidazole were both dominated by FMT colonoscopy. On sensitivity analysis, FMT colonoscopy remained the most cost-effective strategy at cure rates >88.4% and CDI recurrence rates <14.9%. Fidaxomicin required a cost <$1359 to meet our cost-effectiveness threshold. In clinical settings where FMT is not available or applicable, the preferred strategy appears to be initial treatment with oral vancomycin. Conclusions. In this decision analysis examining treatment strategies for recurrent CDI, we demonstrate that FMT colonoscopy is the most cost-effective initial strategy for management of recurrent CDI. PMID:24692533

  14. Telehealth personalized cancer risk communication to motivate colonoscopy in relatives of patients with colorectal cancer: the family CARE Randomized controlled trial.

    PubMed

    Kinney, Anita Y; Boonyasiriwat, Watcharaporn; Walters, Scott T; Pappas, Lisa M; Stroup, Antoinette M; Schwartz, Marc D; Edwards, Sandra L; Rogers, Amy; Kohlmann, Wendy K; Boucher, Kenneth M; Vernon, Sally W; Simmons, Rebecca G; Lowery, Jan T; Flores, Kristina; Wiggins, Charles L; Hill, Deirdre A; Burt, Randall W; Williams, Marc S; Higginbotham, John C

    2014-03-01

    The rate of adherence to regular colonoscopy screening in individuals at increased familial risk of colorectal cancer (CRC) is suboptimal, especially among rural and other geographically underserved populations. Remote interventions may overcome geographic and system-level barriers. We compared the efficacy of a telehealth-based personalized risk assessment and communication intervention with a mailed educational brochure for improving colonoscopy screening among at-risk relatives of patients with CRC. Eligible individuals age 30 to 74 years who were not up-to-date with risk-appropriate screening and were not candidates for genetic testing were recruited after contacting patients with CRC or their next of kin in five states. Enrollees were randomly assigned as family units to either an active, personalized intervention that incorporated evidence-based risk communication and behavior change techniques, or a mailed educational brochure. The primary outcome was medically verified colonoscopy within 9 months of the intervention. Of the 481 eligible and randomly assigned at-risk relatives, 79.8% completed the outcome assessments within 9 months; 35.4% of those in the personalized intervention group and 15.7% of those in the comparison group obtained a colonoscopy. In an intent-to-treat analysis, the telehealth group was almost three times as likely to get screened as the low-intensity comparison group (odds ratio, 2.83; 95% CI, 1.87 to 4.28; P < .001). Persons residing in rural areas and those with lower incomes benefitted at the same level as did urban residents. Remote personalized interventions that consider family history and incorporate evidence-based risk communication and behavior change strategies may promote risk-appropriate screening in close relatives of patients with CRC.

  15. Telehealth Personalized Cancer Risk Communication to Motivate Colonoscopy in Relatives of Patients With Colorectal Cancer: The Family CARE Randomized Controlled Trial

    PubMed Central

    Kinney, Anita Y.; Boonyasiriwat, Watcharaporn; Walters, Scott T.; Pappas, Lisa M.; Stroup, Antoinette M.; Schwartz, Marc D.; Edwards, Sandra L.; Rogers, Amy; Kohlmann, Wendy K.; Boucher, Kenneth M.; Vernon, Sally W.; Simmons, Rebecca G.; Lowery, Jan T.; Flores, Kristina; Wiggins, Charles L.; Hill, Deirdre A.; Burt, Randall W.; Williams, Marc S.; Higginbotham, John C.

    2014-01-01

    Purpose The rate of adherence to regular colonoscopy screening in individuals at increased familial risk of colorectal cancer (CRC) is suboptimal, especially among rural and other geographically underserved populations. Remote interventions may overcome geographic and system-level barriers. We compared the efficacy of a telehealth-based personalized risk assessment and communication intervention with a mailed educational brochure for improving colonoscopy screening among at-risk relatives of patients with CRC. Methods Eligible individuals age 30 to 74 years who were not up-to-date with risk-appropriate screening and were not candidates for genetic testing were recruited after contacting patients with CRC or their next of kin in five states. Enrollees were randomly assigned as family units to either an active, personalized intervention that incorporated evidence-based risk communication and behavior change techniques, or a mailed educational brochure. The primary outcome was medically verified colonoscopy within 9 months of the intervention. Results Of the 481 eligible and randomly assigned at-risk relatives, 79.8% completed the outcome assessments within 9 months; 35.4% of those in the personalized intervention group and 15.7% of those in the comparison group obtained a colonoscopy. In an intent-to-treat analysis, the telehealth group was almost three times as likely to get screened as the low-intensity comparison group (odds ratio, 2.83; 95% CI, 1.87 to 4.28; P < .001). Persons residing in rural areas and those with lower incomes benefitted at the same level as did urban residents. Conclusion Remote personalized interventions that consider family history and incorporate evidence-based risk communication and behavior change strategies may promote risk-appropriate screening in close relatives of patients with CRC. PMID:24449229

  16. Computer-based System for the Virtual-Endoscopic Guidance of Bronchoscopy.

    PubMed

    Helferty, J P; Sherbondy, A J; Kiraly, A P; Higgins, W E

    2007-11-01

    The standard procedure for diagnosing lung cancer involves two stages: three-dimensional (3D) computed-tomography (CT) image assessment, followed by interventional bronchoscopy. In general, the physician has no link between the 3D CT image assessment results and the follow-on bronchoscopy. Thus, the physician essentially performs bronchoscopic biopsy of suspect cancer sites blindly. We have devised a computer-based system that greatly augments the physician's vision during bronchoscopy. The system uses techniques from computer graphics and computer vision to enable detailed 3D CT procedure planning and follow-on image-guided bronchoscopy. The procedure plan is directly linked to the bronchoscope procedure, through a live registration and fusion of the 3D CT data and bronchoscopic video. During a procedure, the system provides many visual tools, fused CT-video data, and quantitative distance measures; this gives the physician considerable visual feedback on how to maneuver the bronchoscope and where to insert the biopsy needle. Central to the system is a CT-video registration technique, based on normalized mutual information. Several sets of results verify the efficacy of the registration technique. In addition, we present a series of test results for the complete system for phantoms, animals, and human lung-cancer patients. The results indicate that not only is the variation in skill level between different physicians greatly reduced by the system over the standard procedure, but that biopsy effectiveness increases.

  17. Dual-Energy CT in Enhancing Subdural Effusions that Masquerade as Subdural Hematomas: Diagnosis with Virtual High-Monochromatic (190-keV) Images.

    PubMed

    Bodanapally, U K; Dreizin, D; Issa, G; Archer-Arroyo, K L; Sudini, K; Fleiter, T R

    2017-10-01

    Extravasation of iodinated contrast into subdural space following contrast-enhanced radiographic studies results in hyperdense subdural effusions, which can be mistaken as acute subdural hematomas on follow-up noncontrast head CTs. Our aim was to identify the factors associated with contrast-enhancing subdural effusion, characterize diffusion and washout kinetics of iodine in enhancing subdural effusion, and assess the utility of dual-energy CT in differentiating enhancing subdural effusion from subdural hematoma. We retrospectively analyzed follow-up head dual-energy CT studies in 423 patients with polytrauma who had undergone contrast-enhanced whole-body CT. Twenty-four patients with enhancing subdural effusion composed the study group, and 24 randomly selected patients with subdural hematoma were enrolled in the comparison group. Postprocessing with syngo.via was performed to determine the diffusion and washout kinetics of iodine. The sensitivity and specificity of dual-energy CT for the diagnosis of enhancing subdural effusion were determined with 120-kV, virtual monochromatic energy (190-keV) and virtual noncontrast images. Patients with enhancing subdural effusion were significantly older (mean, 69 years; 95% CI, 60-78 years; P < .001) and had a higher incidence of intracranial hemorrhage ( P = .001). Peak iodine concentration in enhancing subdural effusions was reached within the first 8 hours of contrast administration with a mean of 0.98 mg/mL (95% CI, 0.81-1.13 mg/mL), and complete washout was achieved at 38 hours. For the presence of a hyperdense subdural collection on 120-kV images with a loss of hyperattenuation on 190-keV and virtual noncontrast images, when considered as a true-positive for enhancing subdural effusion, the sensitivity was 100% (95% CI, 85.75%-100%) and the specificity was 91.67% (95% CI, 73%-99%). Dual-energy CT has a high sensitivity and specificity in differentiating enhancing subdural effusion from subdural hematoma. Hence, dual-energy CT has a potential to obviate follow-up studies. © 2017 by American Journal of Neuroradiology.

  18. [Image fusion, virtual reality, robotics and navigation. Effects on surgical practice].

    PubMed

    Maresceaux, J; Soler, L; Ceulemans, R; Garcia, A; Henri, M; Dutson, E

    2002-05-01

    In the new minimally invasive surgical era, virtual reality, robotics, and image merging have become topics on their own, offering the potential to revolutionize current surgical treatment and assessment. Improved patient care in the digital age seems to be the primary impetus for continued efforts in the field of telesurgery. The progress in endoscopic surgery with regard to telesurgery is manifested by digitization of the pre-, intra-, and postoperative interaction with the patients' surgical disease via computer system integration: so-called Computer Assisted Surgery (CAS). The preoperative assessment can be improved by 3D organ reconstruction, as in virtual colonoscopy or cholangiography, and by planning and practicing surgery using virtual or simulated organs. When integrating all of the data recorded during this preoperative stage, an enhanced reality can be made possible to improve intra-operative patient interactions. CAS allows for increased three-dimensional accuracy, improved precision and the reproducibility of procedures. The ability to store the actions of the surgeon as digitized information also allows for universal, rapid distribution: i.e., the surgeon's activity can be transmitted to the other side of the operating room or to a remote site via high-speed communications links, as was recently demonstrated by our own team during the Lindbergh operation. Furthermore, the surgeon will be able to share his expertise and skill through teleconsultation and telemanipulation, bringing the patient closer to the expert surgical team through electronic means and opening the way to advanced and continuous surgical learning. Finally, for postoperative interaction, virtual reality and simulation can provide us with 4 dimensional images, time being the fourth dimension. This should allow physicians to have a better idea of the disease process in evolution, and treatment modifications based on this view can be anticipated. We are presently determining the accuracy and efficacy of 4 dimensional imaging compared to conventional evaluations.

  19. Mandibular reconstruction with the vascularized fibula flap: comparison of virtual planning surgery and conventional surgery.

    PubMed

    Wang, Y Y; Zhang, H Q; Fan, S; Zhang, D M; Huang, Z Q; Chen, W L; Ye, J T; Li, J S

    2016-11-01

    This study evaluated the accuracy of mandibular reconstruction and assessed clinical outcomes in both virtual planning and conventional surgery patients. ProPlan CMF surgical planning software was used preoperatively in the virtual planning group. In the virtual planning group, fibula flaps were harvested and osteotomized, and the mandibles were resected and reconstructed assisted by the prefabricated cutting guides and templates. The main outcome measures included the operative time, postoperative computed tomography (CT) scans, facial appearance, and occlusal function. The ischemia time and total operation time were shorter in the virtual planning group than in the conventional surgery group. High precision with the use of the cutting guides and templates was found for both the fibula and mandible, and a good fit was noted among the pre-bent plate, mandible, and fibula segments in the virtual planning group. Postoperative CT scans also showed excellent mandibular contours of the fibula flaps in accordance with virtual plans in the virtual planning group. This study demonstrated that virtual surgical planning was able to achieve more accurate mandibular reconstruction than conventional surgery. The use of prefabricated cutting guides and plates makes fibula flap moulding and placement easier, minimizes the operating time, and improves clinical outcomes. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. National CT Colonography Trial (ACRIN 6664): Comparison of Three Full-Laxative Bowel Preparations in More Than 2500 Average-Risk Patients

    PubMed Central

    Hara, Amy K.; Kuo, Mark D.; Blevins, Meridith; Chen, Mei-Hsiu; Yee, Judy; Dachman, Abraham; Menias, Christine O.; Siewert, Betina; Cheema, Jugesh I.; Obregon, Richard G.; Fidler, Jeff L.; Zimmerman, Peter; Horton, Karen M.; Coakley, Kevin; Iyer, Revathy B.; Halvorsen, Robert A.; Casola, Giovanna; Johnson, C. Daniel

    2011-01-01

    OBJECTIVE The purpose of our study was to compare the effect of three different full-laxative bowel preparations on patient compliance, residual stool and fluid, reader confidence, and polyp detection at CT colonography (CTC). SUBJECTS AND METHODS A total of 2531 patients underwent CTC followed by colonoscopy for the American College of Radiology Imaging Network (ACRIN) National CTC Trial. Of this total, 2525 patients used one of three bowel preparations with bisacodyl tablets and stool and fluid tagging: 4 L of polyethylene glycol (PEG); 90 mL of phosphosoda; or 300 mL of magnesium citrate. Patients reported percent compliance with the bowel preparation and radiologists graded each CTC examination for the amount of residual fluid and stool on a scale from 1 (none) to 4 (nondiagnostic). Reader confidence for true-positive findings was reported on a 5-point scale: 1 (low) to 5 (high). Sensitivity and specificity for detecting polyps ≥ 6 mm and ≥ 1 cm compared with colonoscopy were calculated for each preparation. RESULTS The most commonly prescribed preparation was phosphosoda (n = 1403) followed by PEG (n = 1020) and magnesium citrate (n = 102). Phosphosoda had the highest patient compliance (p = 0.01), least residual stool (p < 0.001), and highest reader confidence versus PEG for examinations with polyps (p = 0.06). Magnesium citrate had significantly more residual fluid compared with PEG and phosphosoda (p = 0.006). The sensitivity and specificity for detecting colon polyps ≥ 6 mm and ≥ 1 cm did not differ significantly between preparations. CONCLUSION Polyp detection was comparable for all three preparations, although phosphosoda had significantly higher patient compliance and the least residual stool. PMID:21512073

  1. Colonoscopy screening for colorectal cancer: the outcomes of two recruitment methods.

    PubMed

    Corbett, Mike; Chambers, Sharon L; Shadbolt, Bruce; Hillman, Lybus C; Taupin, Doug

    2004-10-18

    To determine the response to colorectal cancer (CRC) screening by colonoscopy, through direct invitation or through invitation by general practitioners. Two-way comparison of randomised population sampling versus cluster sampling of a representative general practice population in the Australian Capital Territory, May 2002 to January 2004. Invitation to screen, assessment for eligibility, interview, and colonoscopy. 881 subjects aged 55-74 years were invited to screen: 520 from the electoral roll (ER) sample and 361 from the general practice (GP) cluster sample. Response rate, participation rate, and rate of adenomatous polyps in the screened group. Participation was similar in the ER arm (35.1%; 95% CI, 30.2%-40.3%) and the GP arm (40.1%; 95% CI, 29.2%-51.0%) after correcting for ineligibility, which was higher in the ER arm. Superior eligibility in the GP arm was offset by the labour of manual record review. Response rates after two invitations were similar for the two groups (ER arm: 78.8%; 95% CI, 75.1%-82.1%; GP arm: 81.7%; 95% CI, 73.8%-89.6%). Overall, 53.4% ineligibility arose from having a colonoscopy in the past 10 years (ER arm, 98/178; GP arm, 42/84). Of 231 colonoscopies performed, 229 were complete, with 32% of subjects screened having adenomatous polyps. Colonoscopy-based CRC screening yields similar response and participation rates with either random population sampling or general practice cluster sampling, with population sampling through the electoral roll providing greater ease of recruitment.

  2. Expert opinions and scientific evidence for colonoscopy key performance indicators.

    PubMed

    Rees, Colin J; Bevan, Roisin; Zimmermann-Fraedrich, Katharina; Rutter, Matthew D; Rex, Douglas; Dekker, Evelien; Ponchon, Thierry; Bretthauer, Michael; Regula, Jaroslaw; Saunders, Brian; Hassan, Cesare; Bourke, Michael J; Rösch, Thomas

    2016-12-01

    Colonoscopy is a widely performed procedure with procedural volumes increasing annually throughout the world. Many procedures are now performed as part of colorectal cancer screening programmes. Colonoscopy should be of high quality and measures of this quality should be evidence based. New UK key performance indicators and quality assurance standards have been developed by a working group with consensus agreement on each standard reached. This paper reviews the scientific basis for each of the quality measures published in the UK standards. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. A multicenter, randomized controlled trial comparing the identification rate of stigmata of recent hemorrhage and rebleeding rate between early and elective colonoscopy in outpatient-onset acute lower gastrointestinal bleeding: study protocol for a randomized controlled trial.

    PubMed

    Niikura, Ryota; Nagata, Naoyoshi; Yamada, Atsuo; Doyama, Hisashi; Shiratori, Yasutoshi; Nishida, Tsutomu; Kiyotoki, Shu; Yada, Tomoyuki; Fujita, Tomoki; Sumiyoshi, Tetsuya; Hasatani, Kenkei; Mikami, Tatsuya; Honda, Tetsuro; Mabe, Katsuhiro; Hara, Kazuo; Yamamoto, Katsumi; Takeda, Mariko; Takata, Munenori; Tanaka, Mototsugu; Shinozaki, Tomohiro; Fujishiro, Mitsuhiro; Koike, Kazuhiko

    2018-04-03

    The clinical benefit of early colonoscopy within 24 h of arrival in patients with severe acute lower gastrointestinal bleeding (ALGIB) remains controversial. This trial will compare early colonoscopy (performed within 24 h) versus elective colonoscopy (performed between 24 and 96 h) to examine the identification rate of stigmata of recent hemorrhage (SRH) in ALGIB patients. We hypothesize that, compared with elective colonoscopy, early colonoscopy increases the identification of SRH and subsequently improves clinical outcomes. This trial is an investigator-initiated, multicenter, randomized, open-label, parallel-group trial examining the superiority of early colonoscopy over elective colonoscopy (standard therapy) in ALGIB patients. The primary outcome measure is the identification of SRH. Secondary outcomes include 30-day rebleeding, success of endoscopic treatment, need for additional endoscopic examination, need for interventional radiology, need for surgery, need for transfusion during hospitalization, length of stay, 30-day thrombotic events, 30-day mortality, preparation-related adverse events, and colonoscopy-related adverse events. The sample size will enable detection of a 9% SRH rate in elective colonoscopy patients and a SRH rate of ≥ 26% in early colonoscopy patients with a risk of type I error of 5% and a power of 80%. This trial will provide high-quality data on the benefits and risks of early colonoscopy in ALGIB patients. UMIN-CTR Identifier, UMIN000021129 . Registered on 21 February 2016; ClinicalTrials.gov Identifier, NCT03098173 . Registered on 24 March 2017.

  4. Somatostatin receptor immunohistochemistry in neuroendocrine tumors: comparison between manual and automated evaluation

    PubMed Central

    Daniel, Kaemmerer; Maria, Athelogou; Amelie, Lupp; Isabell, Lenhardt; Stefan, Schulz; Luisa, Peter; Merten, Hommann; Vikas, Prasad; Gerd, Binnig; Paul, Baum Richard

    2014-01-01

    Background: Manual evaluation of somatostatin receptor (SSTR) immunohistochemistry (IHC) is a time-consuming and cost-intensive procedure. Aim of the study was to compare manual evaluation of SSTR subtype IHC to an automated software-based analysis, and to in-vivo imaging by SSTR-based PET/CT. Methods: We examined 25 gastroenteropancreatic neuroendocrine tumor (GEP-NET) patients and correlated their in-vivo SSTR-PET/CT data (determined by the standardized uptake values SUVmax,-mean) with the corresponding ex-vivo IHC data of SSTR subtype (1, 2A, 4, 5) expression. Exactly the same lesions were imaged by PET/CT, resected and analyzed by IHC in each patient. After manual evaluation, the IHC slides were digitized and automatically evaluated for SSTR expression by Definiens XD software. A virtual IHC score “BB1” was created for comparing the manual and automated analysis of SSTR expression. Results: BB1 showed a significant correlation with the corresponding conventionally determined Her2/neu score of the SSTR-subtypes 2A (rs: 0.57), 4 (rs: 0.44) and 5 (rs: 0.43). BB1 of SSTR2A also significantly correlated with the SUVmax (rs: 0.41) and the SUVmean (rs: 0.50). Likewise, a significant correlation was seen between the conventionally evaluated SSTR2A status and the SUVmax (rs: 0.42) and SUVmean (rs: 0.62).Conclusion: Our data demonstrate that the evaluation of the SSTR status by automated analysis (BB1 score), using digitized histopathology slides (“virtual microscopy”), corresponds well with the SSTR2A, 4 and 5 expression as determined by conventional manual histopathology. The BB1 score also exhibited a significant association to the SSTR-PET/CT data in accordance with the high affinity profile of the SSTR analogues used for imaging. PMID:25197368

  5. Incomplete colonoscopy: Maximizing completion rates of gastroenterologists

    PubMed Central

    Brahmania, Mayur; Park, Jei; Svarta, Sigrid; Tong, Jessica; Kwok, Ricky; Enns, Robert

    2012-01-01

    BACKGROUND Cecal intubation is one of the goals of a quality colonoscopy; however, many factors increasing the risk of incomplete colonoscopy have been implicated. The implications of missed pathology and the demand on health care resources for return colonoscopies pose a conundrum to many physicians. The optimal course of action after incomplete colonoscopy is unclear. OBJECTIVES: To assess endoscopic completion rates of previously incomplete colonoscopies, the methods used to complete them and the factors that led to the previous incomplete procedure. METHODS: All patients who previously underwent incomplete colonoscopy (2005 to 2010) and were referred to St Paul’s Hospital (Vancouver, British Columbia) were evaluated. Colonoscopies were re-attempted by a single endoscopist. Patient charts were reviewed retrospectively. RESULTS: A total of 90 patients (29 males) with a mean (± SD) age of 58±13.2 years were included in the analysis. Thirty patients (33%) had their initial colonoscopy performed by a gastroenterologist. Indications for initial colonoscopy included surveillance or screening (23%), abdominal pain (15%), gastrointestinal bleeding (29%), change in bowel habits or constitutional symptoms (18%), anemia (7%) and chronic diarrhea (8%). Reasons for incomplete colonoscopy included poor preparation (11%), pain or inadequate sedation (16%), tortuous colon (30%), diverticular disease (6%), obstructing mass (6%) and stricturing disease (10%). Reasons for incomplete procedures in the remaining 21% of patients were not reported by the referring physician. Eighty-seven (97%) colonoscopies were subsequently completed in a single attempt at the institution. Seventy-six (84%) colonoscopies were performed using routine manoeuvres, patient positioning and a variable-stiffness colonoscope (either standard or pediatric). A standard 160 or 180 series Olympus gastroscope (Olympus, Japan) was used in five patients (6%) to navigate through sigmoid diverticular disease; a pediatric colonoscope was used in six patients (7%) for similar reasons. Repeat colonoscopy on the remaining three patients (3%) failed: all three required surgery for strictures (two had obstructing malignant masses and one had a severe benign obstructing sigmoid diverticular stricture). CONCLUSION: Most patients with previous incomplete colonoscopy can undergo a successful repeat colonoscopy at a tertiary care centre with instruments that are readily available to most gastroenterologists. Other modalities for evaluation of the colon should be deferred until a second attempt is made at an expert centre. PMID:22993727

  6. Exploring Hominin and Non-hominin Primate Dental Fossil Remains with Neutron Microtomography

    NASA Astrophysics Data System (ADS)

    Zanolli, Clément; Schillinger, Burkhard; Beaudet, Amélie; Kullmer, Ottmar; Macchiarelli, Roberto; Mancini, Lucia; Schrenk, Friedemann; Tuniz, Claudio; Vodopivec, Vladimira

    Fossil dental remains are an archive of unique information for paleobiological studies. Computed microtomography based on X-ray microfocus sources (X-μCT) and Synchrotron Radiation (SR-μCT) allow subtle quantification at the micron and sub-micron scale of the meso- and microstructural signature imprinted in the mineralized tissues, such as enamel and dentine, through high-resolution ;virtual histology;. Nonetheless, depending on the degree of alterations undergone during fossilization, X-ray analyses of tooth tissues do not always provide distinct imaging contrasts, thus preventing the extraction of essential morphological and anatomical details. We illustrate here by three examples the successful application of neutron microtomography (n-μCT) in cases where X-rays have previously failed to deliver contrasts between dental tissues of fossilized specimen.

  7. Prerequisites of Colonoscopy

    PubMed Central

    Hong, Kyong Hee

    2014-01-01

    Colonoscopy is a widely accepted method for the evaluation of the colon and terminal ileum. Its diagnostic accuracy and therapeutic safety are influenced by prerequisites, including modulation of medication and bowel cleansing. Appropriate choices of sedative medication and bowel-cleansing regimen, together with diet modification, should be made based on the patient's underlying disease, age, and medication intake. Moreover, effective methods for patient education regarding bowel preparation should be considered. PMID:25133119

  8. TU-AB-202-12: A Novel Method to Map Endoscopic Video to CT for Treatment Planning and Toxicity Analysis in Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, W; Yang, J; Beadle, B

    Purpose: Endoscopic examinations are routine procedures for head-and-neck cancer patients. Our goal is to develop a method to map the recorded video to CT, providing valuable information for radiotherapy treatment planning and toxicity analysis. Methods: We map video frames to CT via virtual endoscopic images rendered at the real endoscope’s CT-space coordinates. We developed two complementary methods to find these coordinates by maximizing real-to-virtual image similarity:(1)Endoscope Tracking: moves the virtual endoscope frame-by-frame until the desired frame is reached. Utilizes prior knowledge of endoscope coordinates, but sensitive to local optima. (2)Location Search: moves the virtual endoscope along possible paths through themore » volume to find the desired frame. More robust, but more computationally expensive. We tested these methods on clay phantoms with embedded markers for point mapping and protruding bolus material for contour mapping, and we assessed them qualitatively on three patient exams. For mapped points we calculated 3D-distance errors, and for mapped contours we calculated mean absolute distances (MAD) from CT contours. Results: In phantoms, Endoscope Tracking had average point error=0.66±0.50cm and average bolus MAD=0.74±0.37cm for the first 80% of each video. After that the virtual endoscope got lost, increasing these values to 4.73±1.69cm and 4.06±0.30cm. Location Search had point error=0.49±0.44cm and MAD=0.53±0.28cm. Point errors were larger where the endoscope viewed the surface at shallow angles<10 degrees (1.38±0.62cm and 1.22±0.69cm for Endoscope Tracking and Location Search, respectively). In patients, Endoscope Tracking did not make it past the nasal cavity. However, Location Search found coordinates near the correct location for 70% of test frames. Its performance was best near the epiglottis and in the nasal cavity. Conclusion: Location Search is a robust and accurate technique to map endoscopic video to CT. Endoscope Tracking is sensitive to erratic camera motion and local optima, but could be used in conjunction with anchor points found using Location Search.« less

  9. Evaluation of the CT Parameters to Suppress Renal Cysts Pseudoenhancement Effect: Influence of the Virtual Monochromatic Spectral Images, the Model-based Iterative Reconstruction Algorithm and the Aperture Size in Phantom Model.

    PubMed

    Sugisawa, Koichi; Ichikawa, Katsuhiro; Minamishima, Kazuya; Hasegawa, Masakazu; Yamada, Yoshitake; Jinzaki, Masahiro

    2017-01-01

    The purpose of this study was to evaluate the effect of the virtual monochromatic spectral images (VMSI) and the model-based iterative reconstruction (MBIR) images, to evaluate the influence of the aperture size (40- and 20-mm beam) on renal pseudoenhancement (PE) compared with the filtered back projection (FBP) images. The renal compartment-CT phantom was filled with iodinated contrast material diluted to the attenuation of 180 Hounsfield units (HU) at 120 kV. The water-filled spherical structures, which simulate cyst, were inserted into the renal compartment. Those diameters were 7, 15 and 25 mm. These were scanned by conventional mode (helical scan, 120 kV-FBP) and dual energy mode. 70 keV-VMSI were reconstructed from the dual energy mode, and MBIR images were reconstructed from conventional mode at 40- and 20-mm aperture. Additionally, the phantom was scanned using non-helical mode with 20-mm aperture, and FBP images were reconstructed. The CT value of the PE for cyst areas was measured for these images. The CT values of the cysts were 20.0-14.3 HU on the FBP images, 12.8-12.7 HU on the 70 keV-VMSI (PE-inhibition ratio was 36.0-11.2%) and 16.2-14.0 HU on the MBIR images (19.0-2.1%), respectively, at 40-mm aperture. The PE-inhibition ratio scanned by 20-mm aperture was improved by 28.0% with FBP, 32.8% with 70 keV-VMSI and 29.6% with MBIR compared with 40-mm aperture. One of the FBP images with non-helical mode was 11.6 HU. The best CT technique to minimize PE was the combination of 70 keV-VMSI and 20-mm aperture.

  10. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates.

    PubMed

    Nickenig, Hans-Joachim; Eitner, Stephan

    2007-01-01

    We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.

  11. A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction.

    PubMed

    Zeng, Canjun; Xing, Weirong; Wu, Zhanglin; Huang, Huajun; Huang, Wenhua

    2016-10-01

    Treatment of acetabular fractures remains one of the most challenging tasks that orthopaedic surgeons face. An accurate assessment of the injuries and preoperative planning are essential for an excellent reduction. The purpose of this study was to evaluate the feasibility, accuracy and effectiveness of performing 3D printing technology and computer-assisted virtual surgical procedures for preoperative planning in acetabular fractures. We hypothesised that more accurate preoperative planning using 3D printing models will reduce the operation time and significantly improve the outcome of acetabular fracture repair. Ten patients with acetabular fractures were recruited prospectively and examined by CT scanning. A 3-D model of each acetabular fracture was reconstructed with MIMICS14.0 software from the DICOM file of the CT data. Bone fragments were moved and rotated to simulate fracture reduction and restore the pelvic integrity with virtual fixation. The computer-assisted 3D image of the reduced acetabula was printed for surgery simulation and plate pre-bending. The postoperative CT scan was performed to compare the consistency of the preoperative planning with the surgical implants by 3D-superimposition in MIMICS14.0, and evaluated by Matta's method. Computer-based pre-operations were precisely mimicked and consistent with the actual operations in all cases. The pre-bent fixation plates had an anatomical shape specifically fit to the individual pelvis without further bending or adjustment at the time of surgery and fracture reductions were significantly improved. Seven out of 10 patients had a displacement of fracture reduction of less than 1mm; 3 cases had a displacement of fracture reduction between 1 and 2mm. The 3D printing technology combined with virtual surgery for acetabular fractures is feasible, accurate, and effective leading to improved patient-specific preoperative planning and outcome of real surgery. The results provide useful technical tips in planning pelvic surgeries. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Computer tomography prototyping and virtual procedure simulation in difficult cases of hip replacement surgery.

    PubMed

    Parchi, Paolo Domenico; Ferrari, Vincenzo; Piolanti, Nicola; Andreani, Lorenzo; Condino, Sara; Evangelisti, Gisberto; Lisanti, Michele

    2013-09-01

    Each year approximately 1 million total hip replacements (THR) are performed worldwide. A percentage of failure due to surgical approach and imprecise implant placement still exists. These result in several serious complications. We propose an approach to plan, to simulate, and to assist prosthesis implantation for difficult cases of THR based on 3-D virtual models, generated by segmenting patients' CT images, 3-D solid models, obtained by rapid prototyping (RP), and virtual procedure simulation. We carried out 8 THR with the aid of 3-D reconstruction and RP. After each procedure a questionnaire was submitted to the surgeon to assess the perceived added value of the technology. In all cases, the surgeon evaluated the 3-D model as useful in order to perform the planning. The clinical results showed a mean increase in the Harris Hip Score of about 42.5 points. The mean time of prototyping was 7.3 hours, (min 3.5 hours, max 9.3 hours). The mean surgery time was 65 minutes (min 50 minutes, max 88 minutes). Our study suggests that meticulous preoperative planning is necessary in front of a great aberration of the joint and in absence of normal anatomical landmarks, CT scan is mandatory, and 3-D reconstruction with solid model is useful.

  13. Safety of a 1-Day Polyethylene Glycol 3350 Bowel Preparation for Colonoscopy in Children.

    PubMed

    Sahn, Benjamin; Chen-Lim, Mei Lin; Ciavardone, Denise; Farace, Lisa; Jannelli, Frances; Nieberle, Megan; Ely, Elizabeth; Zhang, Xuemei; Kelsen, Judith; Puma, Anita; Mamula, Petar

    2016-07-01

    Electrolyte-free polyethylene glycol powder (PEG-3350) has been widely used for colonoscopy preparation (prep); however, limited safety data on electrolyte changes exists with 1-day prep regimens. The primary aim of this study was to determine the proportion of patients with significant serum chemistry abnormalities before and at the time of colonoscopy. Secondary aims included evaluation of prep tolerance and bowel cleansing efficacy. We performed a prospective descriptive observational study of pediatric patients scheduled for outpatient colonoscopy who received our standard 1-day, weight-based 4 g/kg PEG-3350 prep with a single stimulant laxative dose and had serum chemistry testing within 60 days before and at the time of colonoscopy. A standardized bowel cleanliness tool (Aronchick scale) was completed by the endoscopist. One hundred fifty-five patients had serum electrolytes data pre- and postprep. Comparison of each patient's chemistries demonstrated statistical equivalence with the 1 exception of blood urea nitrogen levels (P = 0.56). Hypokalemia was detected postprep in 37 subjects (24%), but none had a serum level <3.3 mmol/L, which was deemed to be of no clinical significance. Five patients were hypoglycemic post prep; 3 were 7 years or younger (P = 0.02). The colon cleanliness rating was excellent or good in 77% and suboptimal in 23% of patients. A 1-day, weight-based PEG-3350 bowel prep in children appears safe. Changes in electrolyte levels and renal function were not clinically significant. Children of 7 years or younger seem to be at a higher risk of hypoglycemia compared with older children.

  14. TU-AB-202-03: Prediction of PET Transfer Uncertainty by DIR Error Estimating Software, AUTODIRECT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, H; Chen, J; Phillips, J

    2016-06-15

    Purpose: Deformable image registration (DIR) is a powerful tool, but DIR errors can adversely affect its clinical applications. To estimate voxel-specific DIR uncertainty, a software tool, called AUTODIRECT (automated DIR evaluation of confidence tool), has been developed and validated. This work tests the ability of this software to predict uncertainty for the transfer of standard uptake values (SUV) from positron-emission tomography (PET) with DIR. Methods: Virtual phantoms are used for this study. Each phantom has a planning computed tomography (CT) image and a diagnostic PET-CT image set. A deformation was digitally applied to the diagnostic CT to create the planningmore » CT image and establish a known deformation between the images. One lung and three rectum patient datasets were employed to create the virtual phantoms. Both of these sites have difficult deformation scenarios associated with them, which can affect DIR accuracy (lung tissue sliding and changes in rectal filling). The virtual phantoms were created to simulate these scenarios by introducing discontinuities in the deformation field at the lung rectum border. The DIR algorithm from Plastimatch software was applied to these phantoms. The SUV mapping errors from the DIR were then compared to that predicted by AUTODIRECT. Results: The SUV error distributions closely followed the AUTODIRECT predicted error distribution for the 4 test cases. The minimum and maximum PET SUVs were produced from AUTODIRECT at 95% confidence interval before applying gradient-based SUV segmentation for each of these volumes. Notably, 93.5% of the target volume warped by the true deformation was included within the AUTODIRECT-predicted maximum SUV volume after the segmentation, while 78.9% of the target volume was within the target volume warped by Plastimatch. Conclusion: The AUTODIRECT framework is able to predict PET transfer uncertainty caused by DIR, which enables an understanding of the associated target volume uncertainty.« less

  15. Colorectal Cancer Initial Diagnosis: Screening Colonoscopy, Diagnostic Colonoscopy, or Emergent Surgery, and Tumor Stage and Size at Initial Presentation.

    PubMed

    Moreno, Courtney C; Mittal, Pardeep K; Sullivan, Patrick S; Rutherford, Robin; Staley, Charles A; Cardona, Kenneth; Hawk, Natalyn N; Dixon, W Thomas; Kitajima, Hiroumi D; Kang, Jian; Small, William C; Oshinski, John; Votaw, John R

    2016-03-01

    Rates of colorectal cancer screening are improving but remain suboptimal. Limited information is available regarding how patients are diagnosed with colorectal cancer (for example, asymptomatic screened patients or diagnostic workup because of the presence of symptoms). The purpose of this investigation was to determine how patients were diagnosed with colorectal cancer (screening colonoscopy, diagnostic colonoscopy, or emergent surgery) and tumor stage and size at diagnosis. Adults evaluated between 2011 and 2014 with a diagnosis of colorectal cancer were identified. Clinical notes, endoscopy reports, surgical reports, radiology reports, and pathology reports were reviewed. Sex, race, ethnicity, age at the time of initial diagnosis, method of diagnosis, presenting symptom(s), and primary tumor size and stage at diagnosis were recorded. Colorectal cancer screening history was also recorded. The study population was 54% male (265 of 492) with a mean age of 58.9 years (range, 25-93 years). Initial tissue diagnosis was established at the time of screening colonoscopy in 10.7%, diagnostic colonoscopy in 79.2%, and during emergent surgery in 7.1%. Cancers diagnosed at the time of screening colonoscopy were more likely to be stage 1 than cancers diagnosed at the time of diagnostic colonoscopy or emergent surgery (38.5%, 7.2%, and 0%, respectively). Median tumor size was 3.0 cm for the screening colonoscopy group, 4.6 cm for the diagnostic colonoscopy group, and 5.0 cm for the emergent surgery group. At least 31% of patients diagnosed at the time of screening colonoscopy, 19% of patients diagnosed at the time of diagnostic colonoscopy, and 26% of patients diagnosed at the time of emergent surgery had never undergone a screening colonoscopy. Nearly 90% of colorectal cancer patients were diagnosed after development of symptoms and had more advanced disease than asymptomatic screening patients. Colorectal cancer outcomes will be improved by improving rates of colorectal cancer screening. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Inter-Physician Variation in Follow-Up Colonoscopies after Screening Colonoscopy

    PubMed Central

    Stock, Christian; Hoffmeister, Michael; Birkner, Berndt; Brenner, Hermann

    2013-01-01

    Background and Aims Surveillance is an integral part of the colorectal cancer (CRC) screening process. We aimed to investigate inter-physician variation in follow-up procedures after screening colonoscopy in an opportunistic CRC screening program. Methods A historical cohort study in the German statutory health insurance system was conducted. 55,301 individuals who underwent screening colonoscopy in 2006 in Bavaria, Germany, and who were not diagnosed with CRC were included. Utilization of follow-up colonoscopies performed by the same physician (328 physicians overall) within 3 years was ascertained. Mixed effects logistic regression modelling was used to assess the effect of physicians and other potential predictors (screening result, age group, and sex) on re-utilization of colonoscopy. Physicians were grouped into quintiles according to individual effects estimated in a preliminary model. Predicted probabilities of follow-up colonoscopy by screening result and physician group were calculated. Results The observed rate of follow-up colonoscopy was 6.2% (95% confidence interval: 5.9-6.4%), 18.6% (17.8-19.4%), and 37.0% (35.5-38.4%) after negative colonoscopy, low-risk adenoma and high-risk adenoma detection, respectively. All considered predictors were statistically significantly associated with follow-up colonoscopy. The predicted probabilities of follow-up colonoscopy ranged from 1.7% (1.4-2.0%) to 11.0% (10.2-11.7%), from 7.3% (6.2-8.5%) to 35.1% (32.6-37.7%), and from 17.9% (15.5-20.6%) to 56.9% (53.5-60.3%) in the 1st quintile (lowest rates of follow-up) and 5th quintile (highest rates of follow-up) of physicians after negative colonoscopy, low-risk adenoma and high-risk adenoma detection, respectively. Conclusions This study suggests substantial inter-physician variation in follow-up habits after screening colonoscopy. Interventions, including organizational changes in CRC screening should be considered to reduce this variation. PMID:23874941

  17. Novel application of three-dimensional technologies in a case of dismemberment.

    PubMed

    Baier, Waltraud; Norman, Danielle G; Warnett, Jason M; Payne, Mark; Harrison, Nigel P; Hunt, Nicholas C A; Burnett, Brian A; Williams, Mark A

    2017-01-01

    This case study reports the novel application of three-dimensional technologies such as micro-CT and 3D printing to the forensic investigation of a complex case of dismemberment. Micro-CT was successfully employed to virtually align severed skeletal elements found in different locations, analyse tool marks created during the dismemberment process, and virtually dissect a charred piece of evidence. High resolution 3D prints of the burnt human bone contained within were created for physical visualisation to assist the investigation team. Micro-CT as a forensic radiological method provided vital information and the basis for visualisation both during the investigation and in the subsequent trial making it one of the first examples of such technology in a UK court. Copyright © 2016. Published by Elsevier B.V.

  18. Surveillance colonoscopy after endoscopic treatment for colorectal neoplasia: From the standpoint of the Asia-Pacific region.

    PubMed

    Matsuda, Takahisa; Chiu, Han-Mo; Sano, Yasushi; Fujii, Takahiro; Ono, Akiko; Saito, Yutaka

    2016-04-01

    Colonoscopy is considered the gold standard to detect and remove colorectal neoplasia. The efficacy of colonoscopy with polypectomy to reduce colorectal cancer incidence and mortality has been demonstrated. Recently, post-polypectomy surveillance colonoscopy has become a necessary intervention in daily practice not only in Western countries but also in the Asia-Pacific region. Therefore, it is crucial to establish new clinical practice guidelines to reduce the number of unnecessary surveillance colonoscopies in order to create space for screening colonoscopy. The Asia-Pacific Consensus group recommended that surveillance colonoscopy interval should be tailored according to risk level of index colonoscopy. However, precise guidelines on interval of surveillance cannot be given because of a lack of prospective data. According to Korean and Australian guidelines, surveillance intervals after index colonoscopy of 5 years for low-risk subjects and 3 years for high-risk subjects are recommended in Asia-Pacific regions at present. Prospective data including long-term outcomes from the Japan Polyp Study, which is a multicenter randomized control trial, would be useful to establish the Asia-Pacific consensus in the near future. © 2016 Japan Gastroenterological Endoscopy Society.

  19. New and emerging patient-centered CT imaging and image-guided treatment paradigms for maxillofacial trauma.

    PubMed

    Dreizin, David; Nam, Arthur J; Hirsch, Jeffrey; Bernstein, Mark P

    2018-06-20

    This article reviews the conceptual framework, available evidence, and practical considerations pertaining to nascent and emerging advances in patient-centered CT-imaging and CT-guided surgery for maxillofacial trauma. These include cinematic rendering-a novel method for advanced 3D visualization, incorporation of quantitative CT imaging into the assessment of orbital fractures, low-dose CT imaging protocols made possible with contemporary scanners and reconstruction techniques, the rapidly growing use of cone-beam CT, virtual fracture reduction with design software for surgical pre-planning, the use of 3D printing for fabricating models and implants, and new avenues in CT-guided computer-aided surgery.

  20. Cost-Effectiveness Analysis of Six Strategies to Treat Recurrent Clostridium difficile Infection

    PubMed Central

    Lapointe-Shaw, Lauren; Tran, Kim L.; Coyte, Peter C.; Hancock-Howard, Rebecca L.; Powis, Jeff; Poutanen, Susan M.; Hota, Susy

    2016-01-01

    Objective To assess the cost-effectiveness of six treatment strategies for patients diagnosed with recurrent Clostridium difficile infection (CDI) in Canada: 1. oral metronidazole; 2. oral vancomycin; 3.oral fidaxomicin; 4. fecal transplantation by enema; 5. fecal transplantation by nasogastric tube; and 6. fecal transplantation by colonoscopy. Perspective Public insurer for all hospital and physician services. Setting Ontario, Canada. Methods A decision analytic model was used to model costs and lifetime health effects of each strategy for a typical patient experiencing up to three recurrences, over 18 weeks. Recurrence data and utilities were obtained from published sources. Cost data was obtained from published sources and hospitals in Toronto, Canada. The willingness-to-pay threshold was $50,000/QALY gained. Results Fecal transplantation by colonoscopy dominated all other strategies in the base case, as it was less costly and more effective than all alternatives. After accounting for uncertainty in all model parameters, there was an 87% probability that fecal transplantation by colonoscopy was the most beneficial strategy. If colonoscopy was not available, fecal transplantation by enema was cost-effective at $1,708 per QALY gained, compared to metronidazole. In addition, fecal transplantation by enema was the preferred strategy if the probability of recurrence following this strategy was below 8.7%. If fecal transplantation by any means was unavailable, fidaxomicin was cost-effective at an additional cost of $25,968 per QALY gained, compared to metronidazole. Conclusion Fecal transplantation by colonoscopy (or enema, if colonoscopy is unavailable) is cost-effective for treating recurrent CDI in Canada. Where fecal transplantation is not available, fidaxomicin is also cost-effective. PMID:26901316

  1. Cancer risk awareness and screening uptake in individuals at higher risk for colon cancer: a cross-sectional study

    PubMed Central

    Salimzadeh, Hamideh; Bishehsari, Faraz; Delavari, Alireza; Barzin, Gilda; Amani, Mohammad; Majidi, Azam; Sadjadi, Alireza; Malekzadeh, Reza

    2016-01-01

    Objective We aimed to measure cancer knowledge and feasibility of a screening colonoscopy among a cohort of individuals at higher risk of colon cancer. Methods This study was conducted as part of an ongoing screening cohort, in which first degree relatives (FDRs) of patients with colon cancer are invited to participate in a free of charge screening colonoscopy. We enrolled 1017 FDRs in the study between 2013 and 2014 measuring their data on demographics, cancer knowledge and colonoscopy uptake. A p value of <0.05 was considered statistically significant. Results The relative's mean age was 48.7 years. Only about 28% of FDRs were aware of their increased risk for cancer, near 35.0% had ever heard about colonoscopy with 22% aware of the correct age to start screening. Comparing cancer knowledge of FDRs at high risk versus those at moderate risk, we recorded non-significant differences (p>0.05). Almost two-thirds of FDRs expressed willingness to undergo a colonoscopy and 49.2% completed the procedure, of which 12.8% had advanced neoplasm. Conclusions Our data indicated that remarkable numbers of FDRs were not still informed of their cancer risk or never received a physician recommendation for screening. The desirable uptake at first invitation, which would be higher over successive invitations, supports the feasibility of a family-based recruitment approach for early screening. This has promising implications to introduce targeted screening colonoscopy into the healthcare system in Iran and other developing nations. PMID:27998901

  2. Comparison of Colonoscopy Quality Measures Across Various Practice Settings and the Impact of Performance Scorecards.

    PubMed

    Inra, Jennifer A; Nayor, Jennifer; Rosenblatt, Margery; Mutinga, Muthoka; Reddy, Sarathchandra I; Syngal, Sapna; Kastrinos, Fay

    2017-04-01

    Quality performance measures for screening colonoscopy vary among endoscopists. The impact of practice setting is unknown. We aimed to (1) compare screening colonoscopy performance measures among three different US practice settings; (2) evaluate factors associated with adenoma detection; and (3) assess a scorecard intervention on performance metrics. This multi-center prospective study compared patient, endoscopist, and colonoscopy characteristics performed at a tertiary care hospital (TCH), community-based hospital (CBH), and private practice group (PPG). Withdrawal times (WT), cecal intubation, and adenoma detection rates (ADR) were compared by site at baseline and 12 weeks following scorecard distribution. Generalized linear mixed models identified factors associated with adenoma detection. Twenty-eight endoscopists performed colonoscopies on 1987 asymptomatic, average-risk individuals ≥50 years. Endoscopist and patient characteristics were similar across sites. The PPG screened more men (TCH: 42.8%, CBH: 45.0%, PPG: 54.2%; p < 0.0001). Preparation quality varied with good/excellent results in 70.6, 88.3, and 92% of TCH, CBH, and PPG cases, respectively (p < 0.0001). Male ADRs, cecal intubation, and WT exceeded recommended benchmarks despite variable results at each site; female ADRs were <15% at the PPG which screened the fewest females. Performance remained unchanged following scorecard distribution. Adenoma detection was associated with increasing patient age, male gender, WT, adequate preparation, but not practice setting. Each practice performed high-quality screening colonoscopy. Scorecards did not improve performance metrics. Preparation quality varies among practice settings and can be modified to improve adenoma detection.

  3. Cost-Effectiveness Analysis of Six Strategies to Treat Recurrent Clostridium difficile Infection.

    PubMed

    Lapointe-Shaw, Lauren; Tran, Kim L; Coyte, Peter C; Hancock-Howard, Rebecca L; Powis, Jeff; Poutanen, Susan M; Hota, Susy

    2016-01-01

    To assess the cost-effectiveness of six treatment strategies for patients diagnosed with recurrent Clostridium difficile infection (CDI) in Canada: 1. oral metronidazole; 2. oral vancomycin; 3.oral fidaxomicin; 4. fecal transplantation by enema; 5. fecal transplantation by nasogastric tube; and 6. fecal transplantation by colonoscopy. Public insurer for all hospital and physician services. Ontario, Canada. A decision analytic model was used to model costs and lifetime health effects of each strategy for a typical patient experiencing up to three recurrences, over 18 weeks. Recurrence data and utilities were obtained from published sources. Cost data was obtained from published sources and hospitals in Toronto, Canada. The willingness-to-pay threshold was $50,000/QALY gained. Fecal transplantation by colonoscopy dominated all other strategies in the base case, as it was less costly and more effective than all alternatives. After accounting for uncertainty in all model parameters, there was an 87% probability that fecal transplantation by colonoscopy was the most beneficial strategy. If colonoscopy was not available, fecal transplantation by enema was cost-effective at $1,708 per QALY gained, compared to metronidazole. In addition, fecal transplantation by enema was the preferred strategy if the probability of recurrence following this strategy was below 8.7%. If fecal transplantation by any means was unavailable, fidaxomicin was cost-effective at an additional cost of $25,968 per QALY gained, compared to metronidazole. Fecal transplantation by colonoscopy (or enema, if colonoscopy is unavailable) is cost-effective for treating recurrent CDI in Canada. Where fecal transplantation is not available, fidaxomicin is also cost-effective.

  4. Virtual Reality Exploration and Planning for Precision Colorectal Surgery.

    PubMed

    Guerriero, Ludovica; Quero, Giuseppe; Diana, Michele; Soler, Luc; Agnus, Vincent; Marescaux, Jacques; Corcione, Francesco

    2018-06-01

    Medical software can build a digital clone of the patient with 3-dimensional reconstruction of Digital Imaging and Communication in Medicine images. The virtual clone can be manipulated (rotations, zooms, etc), and the various organs can be selectively displayed or hidden to facilitate a virtual reality preoperative surgical exploration and planning. We present preliminary cases showing the potential interest of virtual reality in colorectal surgery for both cases of diverticular disease and colonic neoplasms. This was a single-center feasibility study. The study was conducted at a tertiary care institution. Two patients underwent a laparoscopic left hemicolectomy for diverticular disease, and 1 patient underwent a laparoscopic right hemicolectomy for cancer. The 3-dimensional virtual models were obtained from preoperative CT scans. The virtual model was used to perform preoperative exploration and planning. Intraoperatively, one of the surgeons was manipulating the virtual reality model, using the touch screen of a tablet, which was interactively displayed to the surgical team. The main outcome was evaluation of the precision of virtual reality in colorectal surgery planning and exploration. In 1 patient undergoing laparoscopic left hemicolectomy, an abnormal origin of the left colic artery beginning as an extremely short common trunk from the inferior mesenteric artery was clearly seen in the virtual reality model. This finding was missed by the radiologist on CT scan. The precise identification of this vascular variant granted a safe and adequate surgery. In the remaining cases, the virtual reality model helped to precisely estimate the vascular anatomy, providing key landmarks for a safer dissection. A larger sample size would be necessary to definitively assess the efficacy of virtual reality in colorectal surgery. Virtual reality can provide an enhanced understanding of crucial anatomical details, both preoperatively and intraoperatively, which could contribute to improve safety in colorectal surgery.

  5. CT colonography: accuracy, acceptance, safety and position in organised population screening.

    PubMed

    de Haan, Margriet C; Pickhardt, Perry J; Stoker, Jaap

    2015-02-01

    Colorectal cancer (CRC) is the second most common cancer and second most common cause of cancer-related deaths in Europe. The introduction of CRC screening programmes using stool tests and flexible sigmoidoscopy, have been shown to reduce CRC-related mortality substantially. In several European countries, population-based CRC screening programmes are ongoing or being rolled out. Stool tests like faecal occult blood testing are non-invasive and simple to perform, but are primarily designed to detect early invasive cancer. More invasive tests like colonoscopy and CT colonography (CTC) aim at accurately detecting both CRC and cancer precursors, thus providing for cancer prevention. This review focuses on the accuracy, acceptance and safety of CTC as a CRC screening technique and on the current position of CTC in organised population screening. Based on the detection characteristics and acceptability of CTC screening, it might be a viable screening test. The potential disadvantage of radiation exposure is probably overemphasised, especially with newer technology. At this time-point, it is not entirely clear whether the detection of extracolonic findings at CTC is of net benefit and is cost effective, but with responsible handling, this may be the case. Future efforts will seek to further improve the technique, refine appropriate diagnostic algorithms and study cost-effectiveness. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Monte Carlo calculations for reporting patient organ doses from interventional radiology

    NASA Astrophysics Data System (ADS)

    Huo, Wanli; Feng, Mang; Pi, Yifei; Chen, Zhi; Gao, Yiming; Xu, X. George

    2017-09-01

    This paper describes a project to generate organ dose data for the purposes of extending VirtualDose software from CT imaging to interventional radiology (IR) applications. A library of 23 mesh-based anthropometric patient phantoms were involved in Monte Carlo simulations for database calculations. Organ doses and effective doses of IR procedures with specific beam projection, filed of view (FOV) and beam quality for all parts of body were obtained. Comparing organ doses for different beam qualities, beam projections, patients' ages and patient's body mass indexes (BMIs) which generated by VirtualDose-IR, significant discrepancies were observed. For relatively long time exposure, IR doses depend on beam quality, beam direction and patient size. Therefore, VirtualDose-IR, which is based on the latest anatomically realistic patient phantoms, can generate accurate doses for IR treatment. It is suitable to apply this software in clinical IR dose management as an effective tool to estimate patient doses and optimize IR treatment plans.

  7. [Acceptance and willingness-to-pay for colorectal colonoscopy screening among high-risk populations for colorectal cancer in urban China].

    PubMed

    Shi, Jufang; Huang, Huiyao; Guo, Lanwei; Ren, Jiansong; Ren, Ying; Lan, Li; Zhou, Qi; Mao, Ayan; Qi, Xiao; Liao, Xianzhen; Liu, Guoxiang; Bai, Yana; Cao, Rong; Liu, Yuqin; Wang, Yuanzheng; Gong, Jiyong; Li, Ni; Zhang, Kai; He, Jie; Dai, Min

    2015-05-01

    To survey the acceptance and willingness-to-pay for colorectal cancer colonoscopy screening among high risk populations in urban China. From 2012 to 2013, a Cancer Screening Program in Urban China (CanSPUC) was initiated in 9 provinces, the current survey was conducted among those participants who were evaluated as "high risk for colorectal cancer" by a risk-factor-evaluation-model (community-based) and then went through a colonoscopy screening procedure (hospital-based). All the data were obtained through a questionnaire-based interview (face-to-face or self-completed), mainly focusing on the acceptance and willingness-to-pay of the participants for colorectal colonoscopy screening. The current analysis included a total of 1 624 participants, with an median age of 55.0 years (P25 = 49.0, P75 = 61.0 years) and an annual income per capita of 17 thousand (range: 10-25 thousand) Chinese Yuan (CNY), 42.8% (695/1 624) of whom were males. Of all the participants, 87.0% (1 414/1 624) could totally or substantially accept the colonoscopy screening, particularly in those at higher education level (junior high school: OR = 0.34, 95% CI: 0.22-0.52; high school OR = 0.41, 95% CI: 0.26-0.66; college or over OR = 0.35, 95% CI: 0.20-0.59). Of all the participants, 13.0% (210/1 624) could not or hardly accept it, particularly in those with older age (60-69 years) (OR = 1.48, 95% CI: 1.06-2.07), not in marriage (OR = 2.15, 95% CI: 1.25-3.70) or with family member(s) to raise (OR = 1.60, 95% CI: 1.17-2.20). 1 388 (85.5%) of all the participants had willingness-to-pay for a long-term colonoscopy screening service, particularly in those working in public (OR = 0.61, 95% CI: 0.44-0.84) or enterprise sectors (OR = 0.60, 95% CI: 0.38-0.94), but 82.3% (1 141/1 386) of whom would only pay less than 100 CNY; 14.5% (236/1 624) of total had no willingness-to-pay, particularly in those living in areas with moderate (OR = 4.08, 95% CI: 2.75-6.33) or high GDP per capita (OR = 3.26, 95% CI: 2.11-4.92), or with an absence of willingness-to-pay for colonoscopy screening (OR = 3.98, 95% CI: 2.81-5.65). Although a larger community-based colorectal cancer screening program was warranted to examine the extrapolation of these findings, it suggested that the acceptance for colorectal cancer colonoscopy screening among the selected high-risk populations was considerable. The willing-to-pay was relatively high but the amount of payment was limited, the indicated subgroups with potentially less acceptance or willingness need to be more focused in the future to reach a higher participation rate. The data will also be informative in integrating the screening service into the local health insurance system.

  8. Budget-impact model for colonoscopy cost calculation and comparison between 2 litre PEG+ASC and sodium picosulphate with magnesium citrate or sodium phosphate oral bowel cleansing agents.

    PubMed

    Gruss, H-J; Cockett, A; Leicester, R J

    2012-01-01

    With the availability of several bowel cleansing agents, physicians and hospitals performing colonoscopies will often base their choice of cleansing agent purely on acquisition cost. Therefore, an easy to use budget impact model has been developed and established as a tool to compare total colon preparation costs between different established bowel cleansing agents. The model was programmed in Excel and designed as a questionnaire evaluating information on treatment costs for a range of established bowel cleansing products. The sum of costs is based on National Health Service reference costs for bowel cleansing products. Estimations are made for savings achievable when using a 2-litre polyethylene glycol with ascorbate components solution (PEG+ASC) in place of other bowel cleansing solutions. Test data were entered into the model to confirm validity and sensitivity. The model was then applied to a set of audit cost data from a major hospital colonoscopy unit in the UK. Descriptive analysis of the test data showed that the main cost drivers in the colonoscopy process are the procedure costs and costs for bed days rather than drug acquisition costs, irrespective of the cleansing agent. Audit data from a colonoscopy unit in the UK confirmed the finding with a saving of £107,000 per year in favour of PEG+ASC when compared to sodium picosulphate with magnesium citrate solution (NaPic+MgCit). For every patient group the model calculated overall cost savings. This was irrespective of the higher drug expenditure associated with the use of PEG+ASC for bowel preparation. Savings were mainly realized through reduced costs for repeat colonoscopy procedures and associated costs, such as inpatient length of stay. The budget impact model demonstrated that the primary cost driver was the procedure cost for colonoscopy. Savings can be realized through the use of PEG+ASC despite higher drug acquisition costs relative to the comparator products. From a global hospital funding perspective, the acquisition costs of bowel preparations should not be used as the primary reason to select the preferred treatment agent, but should be part of the consideration, with an emphasis on the clinical outcome.

  9. Making every colonoscopy count: Ensuring quality in endoscopy.

    PubMed

    Bourke, Michael J

    2009-10-01

    The last few years have seen a burgeoning interest in the measurement of clinical performance and its impact on quality standards. The advent of the National Bowel Cancer Screening Program has highlighted the many deficiencies that exist in the provision of colonoscopy services in Australia. These include the absence of an agreed tool to measure the quality of colonoscopy on either an individual, departmental or regional basis and the absence of an endoscopic or colonoscopy training curriculum or an agreed standard for colonoscopy trainers. This review will discuss the current status and shortfalls of measuring quality in colonoscopy, highlight some recent initiatives by the Gastroenterological Society of Australia and articulate a direction for the future.

  10. Perforated Appendicitis After Colonoscopy

    PubMed Central

    Johnston, Paul

    2008-01-01

    Background: Acute appendicitis is a rare complication of colonoscopy that has been reported only 12 times in the English-language literature and is usually associated with obstruction of the appendiceal lumen with fecal matter during colonoscopy. None of the previous reports have described findings of perforation of the appendix within 24 hours of colonoscopy. Methods: We present the case report of a patient who underwent urgent laparotomy within 16 hours of colonos-copy for findings of free intraabdominal air and peritonitis from acute perforated appendicitis. Results: Laparoscopy confirmed 2 perforations of the appendix and diffuse peritonitis. Laparotomy was necessary to perform appendectomy, exclude a right colonic injury, and control intraabdominal sepsis. Conclusion: In patients with abdominal pain who have had a recent colonoscopy, a high index of suspicion is necessary for accurate diagnosis of perforated appendicitis. Perforation can occur hours after colonoscopy even when a biopsy is not performed. PMID:18765066

  11. Virtual pathology of cervical radiculopathy based on 3D MR/CT fusion images: impingement, flattening or twisted condition of the compressed nerve root in three cases.

    PubMed

    Kamogawa, Junji; Kato, Osamu; Morizane, Tatsunori; Hato, Taizo

    2015-01-01

    There have been several imaging studies of cervical radiculopathy, but no three-dimensional (3D) images have shown the path, position, and pathological changes of the cervical nerve roots and spinal root ganglion relative to the cervical bony structure. The objective of this study was to introduce a technique that enables the virtual pathology of the nerve root to be assessed using 3D magnetic resonance (MR)/computed tomography (CT) fusion images that show the compression of the proximal portion of the cervical nerve root by both the herniated disc and the preforaminal or foraminal bony spur in patients with cervical radiculopathy. MR and CT images were obtained from three patients with cervical radiculopathy. 3D MR images were placed onto 3D CT images using a computer workstation. The entire nerve root could be visualized in 3D with or without the vertebrae. The most important characteristic evident on the images was flattening of the nerve root by a bony spur. The affected root was constricted at a pre-ganglion site. In cases of severe deformity, the flattened portion of the root seemed to change the angle of its path, resulting in twisted condition. The 3D MR/CT fusion imaging technique enhances visualization of pathoanatomy in cervical hidden area that is composed of the root and intervertebral foramen. This technique provides two distinct advantages for diagnosis of cervical radiculopathy. First, the isolation of individual vertebra clarifies the deformities of the whole root groove, including both the uncinate process and superior articular process in the cervical spine. Second, the tortuous or twisted condition of a compressed root can be visualized. The surgeon can identify the narrowest face of the root if they view the MR/CT fusion image from the posterolateral-inferior direction. Surgeons use MR/CT fusion images as a pre-operative map and for intraoperative navigation. The MR/CT fusion images can also be used as educational materials for all hospital staff and for patients and patients' families who provide informed consent for treatments.

  12. Creation of anatomical models from CT data

    NASA Astrophysics Data System (ADS)

    Alaytsev, Innokentiy K.; Danilova, Tatyana V.; Manturov, Alexey O.; Mareev, Gleb O.; Mareev, Oleg V.

    2018-04-01

    Computed tomography is a great source of biomedical data because it allows a detailed exploration of complex anatomical structures. Some structures are not visible on CT scans, and some are hard to distinguish due to partial volume effect. CT datasets require preprocessing before using them as anatomical models in a simulation system. The work describes segmentation and data transformation methods for an anatomical model creation from the CT data. The result models may be used for visual and haptic rendering and drilling simulation in a virtual surgery system.

  13. [Appropriateness of colonoscopy indications according to the new EPAGE II criteria].

    PubMed

    Carrión, Silvia; Marín, Ingrid; Lorenzo-Zúñiga, Vicente; Moreno De Vega, Vicente; Boix, Jaume

    2010-01-01

    The appropriateness criteria for colonoscopy developed by a European expert panel (EPAGE), published in 1999, were revised this year (EPAGE II), but have not yet been evaluated. (1) To analyze colonoscopies performed at our hospital, and (2) to evaluate the appropriateness of the new EPAGE II criteria. We retrospectively analyzed 700 colonoscopies (48% males, mean age 58 years). Forty-five colonoscopies (6.4%) were excluded for insufficient bowel preparation or elective indication. EPAGE II criteria classified colonoscopies as "appropriate", "inappropriate" and "uncertain". Ninety-four percent (n=655) of colonoscopies were evaluated. The most frequent indication for colonoscopy (19%) was screening of colorectal cancer (CRC). Seventy percent of colonoscopies were "appropriate", and 18% were "inappropriate", with significant differences according to where the request was made. The most inappropriate indication was postpolypectomy follow-up, due to shorter follow-up intervals. An endoscopic diagnosis was made in 315 patients (48%), with a finding of significant lesions in 25% (n=167; CCR, adenomas, inflammatory bowel disease, angiodysplasia and benign stricture). The indications most frequently associated with relevant findings were screening of CRC (17.3%) and postpolypectomy follow-up (16.7%) but this association was non-significant. Only iron-deficiency anemia was significantly associated with CRC (p<0.0001). Eighteen percent of requests for colonoscopy were inappropriate and 12% provided incomplete information. The indication most strongly associated with a diagnosis of CRC was iron-deficiency anemia. The EPAGE II criteria showed a significant correlation with an endoscopic diagnosis of CRC.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jung, Hyunuk; Kum, Oyeon; Han, Youngyih, E-mail: youngyih@skku.edu

    Purpose: In proton therapy, collisions between the patient and nozzle potentially occur because of the large nozzle structure and efforts to minimize the air gap. Thus, software was developed to predict such collisions between the nozzle and patient using treatment virtual simulation. Methods: Three-dimensional (3D) modeling of a gantry inner-floor, nozzle, and robotic-couch was performed using SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized right before CT scanning. Using the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT imagemore » of a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of the gantry, nozzle, and couch in real scale. A collision, if any, was examined both in static and dynamic modes. The static mode assessed collisions only at fixed positions of the machine’s components, while the dynamic mode operated any time a component was in motion. A collision was identified if any voxels of two components, e.g., the nozzle and the patient or couch, overlapped when calculating volume locations. The event and collision point were visualized, and collision volumes were reported. Results: All components were successfully assembled, and the motions were accurately controlled. The 3D-shape of the phantom agreed with CT images within a deviation of 2 mm. Collision situations were simulated within minutes, and the results were displayed and reported. Conclusions: The developed software will be useful in improving patient safety and clinical efficiency of proton therapy.« less

  15. Variations in colonoscopy practice in Europe: a multicentre descriptive study (EPAGE).

    PubMed

    Harris, Jennifer K; Vader, John-Paul; Wietlisbach, Vincent; Burnand, Bernard; Gonvers, Jean-Jacques; Froehlich, Florian

    2007-01-01

    The volume of colonoscopies performed is increasing and differences in colonoscopy practice over time and between centres have been reported. Examination of current practice is important for bench-marking quality. The objective of this study was to examine variations in colonoscopy practice in endoscopy centres internationally. This observational study prospectively included consecutive patients referred for colonoscopy from 21 centres in 11 countries. Patient, procedure and centre characteristics were collected through questionnaires. Descriptive statistics were performed and the variation between centres while controlling for case-mix was examined. A total of 6004 patients were included in the study. Most colonoscopies (93%; range between centres 70-100%) were performed for diagnostic purposes. The proportion of main indications for colonoscopy showed wide variations between centres, the two most common indications, surveillance and haematochezia, ranging between 7-24% and 5-38%, respectively. High-quality cleansing occurred in 74% (range 51-94%) of patients, and 30% (range 0-100%) of patients received deep sedation. Three-quarters (range 0-100%) of the patients were monitored during colonoscopy, and one-quarter (range 14-35%) underwent polypectomy. Colonoscopy was complete in 89% (range 69-98%) of patients and the median total duration was 20 min (range of centre medians 15-30 min). The variation between centres was not reduced when case-mix was controlled for. This study documented wide variations in colonoscopy practice between centres. Controlling for case-mix did not remove these variations, indicating that centre and procedure characteristics play a role. Centres generally were within the existing guidelines, although there is still some work to be done to ensure that all centres attain the goal of providing high-quality colonoscopy.

  16. The factors associated with negative colonoscopy in screening subjects with positive immunochemical stool occult blood test outcomes.

    PubMed

    Ting, Po-Hsiang; Lin, Xi-Hsuan; Jiang, Jeng-Kai; Luo, Jiing-Chyuan; Chen, Ping-Hsien; Wang, Yen-Po; Hsin, I-Fang; Perng, Chin Lin; Hou, Ming-Chih; Lee, Fa-Yauh

    2018-05-16

    The immunochemical fecal occult blood test (iFOBT) is an alternative method to colonoscopy that can be used for colorectal cancer (CRC) screening. If the iFOBT result is positive, a colonoscopy is recommended. In this retrospective study, we identify factors associated with negative colonoscopy and positive iFOBT results obtained during CRC screening. We collected data for subjects who received a colonoscopy at Taipei Veterans General Hospital after receiving a positive iFOBT result during CRC screening from January 2015 to December 2015. Subjects' baseline data, medications, and co-morbidities as well as colonoscopy and histological findings were recorded. A negative colonoscopy result was defined as no detection of any colorectal neoplasia including non-advanced adenoma, advanced adenoma, and adenocarciona. Multivariate logistic regression analysis was conducted to identify the associated factors in screening subjects with positive iFOBT but negative colonoscopy results. 559 (46.3%) out of 1207 eligible study subjects received a colonoscopy with a negative result. Multivariate logistic regression analysis revealed that the use of antiplatelets [odds ratio (OR) = 0.654; 95% confidence interval (CI), 0.434-0.986], occurrence of hemorrhoid (OR = 0.595; 95% CI, 0.460-0.768), and the existence of colitis/ulcer (OR = 0.358; 95% CI, 0.162-0.789) were independent factors associated with negative colonoscopy but positive iFOBT results during CRC screening. The colon clean level, underlying diseases of gastrointestinal bleeding tendency (e.g., chronic kidney disease, cirrhosis), and the use of anticoagulant or nonsteroidal anti-inflammatory agents were not associated with negative colonoscopy and positive iFOBT results. The use of antiplatelet agents and the presence of hemorrhoids and colitis/ulcers were factors associated with negative colonoscopy and positive iFOBT results. Copyright © 2018. Published by Elsevier Taiwan LLC.

  17. Does massive intraabdominal free gas require surgical intervention?

    PubMed

    Furihata, Tadashi; Furihata, Makoto; Ishikawa, Kunibumi; Kosaka, Masato; Satoh, Naoki; Kubota, Keiichi

    2016-08-28

    We describe a rare case of an 81-year-old man who presented with severe epigastralgia. A chest radiograph showed massive free gas bilaterally in the diaphragmatic spaces. Computed tomography (CT) scan also showed massive free gas in the peritoneal cavity with portal venous gas. We used a wait-and-see approach and carefully considered surgery again when the time was appropriate. The patient received conservative therapy with fasting, an intravenous infusion of antibiotics, and nasogastric intubation. The patient soon recovered and was able to start eating meals 4 d after treatment; thus, surgical intervention was avoided. Thereafter, colonoscopy examination showed pneumatosis cystoides intestinalis in the ascending colon. On retrospective review, CT scan demonstrated sporadic air-filled cysts in the ascending colon. The present case taught us a lesson: the presence of massive intraabdominal free gas with portal venous gas does not necessarily require surgical intervention. Pneumatosis cystoides intestinalis should be considered as a potential causative factor of free gas with portal venous gas when making the differential diagnosis.

  18. A nurse-led model at public academic hospitals maintains high adherence to colorectal cancer surveillance guidelines.

    PubMed

    Symonds, Erin L; Simpson, Kalindra; Coats, Michelle; Chaplin, Angela; Saxty, Karen; Sandford, Jayne; Young Am, Graeme P; Cock, Charles; Fraser, Robert; Bampton, Peter A

    2018-06-18

    To examine the compliance of colorectal cancer surveillance decisions for individuals at greater risk with current evidence-based guidelines and to determine whether compliance differs between surveillance models. Prospective auditing of compliance of surveillance decisions with evidence-based guidelines (NHMRC) in two decision-making models: nurse coordinator-led decision making in public academic hospitals and physician-led decision making in private non-academic hospitals. Selected South Australian hospitals participating in the Southern Co-operative Program for the Prevention of Colorectal Cancer (SCOOP). Proportions of recall recommendations that matched NHMRC guideline recommendations (March-May 2015); numbers of surveillance colonoscopies undertaken more than 6 months ahead of schedule (January-December 2015); proportions of significant neoplasia findings during the 15 years of SCOOP operation (2000-2015). For the nurse-led/public academic hospital model, the recall interval recommendation following 398 of 410 colonoscopies (97%) with findings covered by NHMRC guidelines corresponded to the guideline recommendations; for the physician-led/private non-academic hospital model, this applied to 257 of 310 colonoscopies (83%) (P < 0.001). During 2015, 27% of colonoscopies in public academic hospitals (mean, 27 months; SD, 13 months) and 20% of those in private non-academic hospitals (mean, 23 months; SD, 12 months) were performed more than 6 months earlier than scheduled, in most cases because of patient-related factors (symptoms, faecal occult blood test results). The ratio of the numbers of high risk adenomas to cancers increased from 6.6:1 during 2001-2005 to 16:1 during 2011-2015. The nurse-led/public academic hospital model for decisions about colorectal cancer surveillance intervals achieves a high degree of compliance with guideline recommendations, which should relieve burdening of colonoscopy resources.

  19. Effectiveness of a multimedia-based educational intervention for improving colon cancer literacy in screening colonoscopy patients.

    PubMed

    Hassinger, James P; Holubar, Stefan D; Pendlimari, Rajesh; Dozois, Eric J; Larson, David W; Cima, Robert R

    2010-09-01

    Limited data exist regarding colon cancer literacy in screening colonoscopy patients. We aimed to prospectively assess baseline colon cancer literacy and to determine whether a multimedia educational intervention was associated with improved colon cancer literacy. Colon cancer literacy was assessed in a convenience sample of colonoscopy patients before and after educational intervention. Statistically significant associations with colon cancer literacy scores were assessed by use of multivariate logistic regression analysis. Results are frequency (proportion), mean +/- SD, and odds ratio (OR (95% CI)). Seventy-three subjects participated: mean age, 57 +/- 12 years, 35 (48%) were women, 41 (57%) had a college degree, 43 (59%) had prior colonoscopy, 21 (29%) were accompanying family, and 16 (22%) were health care employees. Multivariate factors associated with a higher baseline colon cancer literacy score included health care employee status (7.9 (95% CI, 1.6-63); P = .02) and family colon cancer history (5.3 (95% CI, 1.3-25); P = .02). After multimedia education, mean scores improved from 53% +/- 23% to 88% +/- 12% (Delta = 35%; P < .0001). On univariate analysis, college-educated subjects had higher final scores (91% vs 83%; P = .007), but this association was not significant on multivariate regression (P = .07). Only baseline score was associated with higher postintervention score (1.7 (95% CI, 1.2-2.6); P = .005). Sixty-two subjects (86%) were very satisfied, and 70 (97%) would recommend the module to friends and family. A knowledge deficit of colon cancer-related concepts is frequently observed in patients undergoing screening colonoscopy. Multimedia-based educational intervention was an effective, satisfying strategy for addressing cancer-specific knowledge deficit in laypersons.

  20. Patient‐specific CT dosimetry calculation: a feasibility study

    PubMed Central

    Xie, Huchen; Cheng, Jason Y.; Ning, Holly; Zhuge, Ying; Miller, Robert W.

    2011-01-01

    Current estimation of radiation dose from computed tomography (CT) scans on patients has relied on the measurement of Computed Tomography Dose Index (CTDI) in standard cylindrical phantoms, and calculations based on mathematical representations of “standard man”. Radiation dose to both adult and pediatric patients from a CT scan has been a concern, as noted in recent reports. The purpose of this study was to investigate the feasibility of adapting a radiation treatment planning system (RTPS) to provide patient‐specific CT dosimetry. A radiation treatment planning system was modified to calculate patient‐specific CT dose distributions, which can be represented by dose at specific points within an organ of interest, as well as organ dose‐volumes (after image segmentation) for a GE Light Speed Ultra Plus CT scanner. The RTPS calculation algorithm is based on a semi‐empirical, measured correction‐based algorithm, which has been well established in the radiotherapy community. Digital representations of the physical phantoms (virtual phantom) were acquired with the GE CT scanner in axial mode. Thermoluminescent dosimeter (TLDs) measurements in pediatric anthropomorphic phantoms were utilized to validate the dose at specific points within organs of interest relative to RTPS calculations and Monte Carlo simulations of the same virtual phantoms (digital representation). Congruence of the calculated and measured point doses for the same physical anthropomorphic phantom geometry was used to verify the feasibility of the method. The RTPS algorithm can be extended to calculate the organ dose by calculating a dose distribution point‐by‐point for a designated volume. Electron Gamma Shower (EGSnrc) codes for radiation transport calculations developed by National Research Council of Canada (NRCC) were utilized to perform the Monte Carlo (MC) simulation. In general, the RTPS and MC dose calculations are within 10% of the TLD measurements for the infant and child chest scans. With respect to the dose comparisons for the head, the RTPS dose calculations are slightly higher (10%–20%) than the TLD measurements, while the MC results were within 10% of the TLD measurements. The advantage of the algebraic dose calculation engine of the RTPS is a substantially reduced computation time (minutes vs. days) relative to Monte Carlo calculations, as well as providing patient‐specific dose estimation. It also provides the basis for a more elaborate reporting of dosimetric results, such as patient specific organ dose volumes after image segmentation. PACS numbers: 87.55.D‐, 87.57.Q‐, 87.53.Bn, 87.55.K‐ PMID:22089016

  1. Accuracy of both virtual and printed 3-dimensional models for volumetric measurement of alveolar clefts before grafting with alveolar bone compared with a validated algorithm: a preliminary investigation.

    PubMed

    Kasaven, C P; McIntyre, G T; Mossey, P A

    2017-01-01

    Our objective was to assess the accuracy of virtual and printed 3-dimensional models derived from cone-beam computed tomographic (CT) scans to measure the volume of alveolar clefts before bone grafting. Fifteen subjects with unilateral cleft lip and palate had i-CAT cone-beam CT scans recorded at 0.2mm voxel and sectioned transversely into slices 0.2mm thick using i-CAT Vision. Volumes of alveolar clefts were calculated using first a validated algorithm; secondly, commercially-available virtual 3-dimensional model software; and finally 3-dimensional printed models, which were scanned with microCT and analysed using 3-dimensional software. For inter-observer reliability, a two-way mixed model intraclass correlation coefficient (ICC) was used to evaluate the reproducibility of identification of the cranial and caudal limits of the clefts among three observers. We used a Friedman test to assess the significance of differences among the methods, and probabilities of less than 0.05 were accepted as significant. Inter-observer reliability was almost perfect (ICC=0.987). There were no significant differences among the three methods. Virtual and printed 3-dimensional models were as precise as the validated computer algorithm in the calculation of volumes of the alveolar cleft before bone grafting, but virtual 3-dimensional models were the most accurate with the smallest 95% CI and, subject to further investigation, could be a useful adjunct in clinical practice. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Printed three-dimensional anatomic templates for virtual preoperative planning before reconstruction of old pelvic injuries: initial results.

    PubMed

    Wu, Xin-Bao; Wang, Jun-Qiang; Zhao, Chun-Peng; Sun, Xu; Shi, Yin; Zhang, Zi-An; Li, Yu-Neng; Wang, Man-Yi

    2015-02-20

    Old pelvis fractures are among the most challenging fractures to treat because of their complex anatomy, difficult-to-access surgical sites, and the relatively low incidence of such cases. Proper evaluation and surgical planning are necessary to achieve the pelvic ring symmetry and stable fixation of the fracture. The goal of this study was to assess the use of three-dimensional (3D) printing techniques for surgical management of old pelvic fractures. First, 16 dried human cadaveric pelvises were used to confirm the anatomical accuracy of the 3D models printed based on radiographic data. Next, nine clinical cases between January 2009 and April 2013 were used to evaluate the surgical reconstruction based on the 3D printed models. The pelvic injuries were all type C, and the average time from injury to reconstruction was 11 weeks (range: 8-17 weeks). The workflow consisted of: (1) Printing patient-specific bone models based on preoperative computed tomography (CT) scans, (2) virtual fracture reduction using the printed 3D anatomic template, (3) virtual fracture fixation using Kirschner wires, and (4) preoperatively measuring the osteotomy and implant position relative to landmarks using the virtually defined deformation. These models aided communication between surgical team members during the procedure. This technique was validated by comparing the preoperative planning to the intraoperative procedure. The accuracy of the 3D printed models was within specification. Production of a model from standard CT DICOM data took 7 hours (range: 6-9 hours). Preoperative planning using the 3D printed models was feasible in all cases. Good correlation was found between the preoperative planning and postoperative follow-up X-ray in all nine cases. The patients were followed for 3-29 months (median: 5 months). The fracture healing time was 9-17 weeks (mean: 10 weeks). No delayed incision healing, wound infection, or nonunions occurred. The results were excellent in two cases, good in five, and poor in two based on the Majeed score. The 3D printing planning technique for pelvic surgery was successfully integrated into a clinical workflow to improve patient-specific preoperative planning by providing a visual and haptic model of the injury and allowing patient-specific adaptation of each osteosynthesis implant to the virtually reduced pelvis.

  3. Head-mounted display augmented reality to guide pedicle screw placement utilizing computed tomography.

    PubMed

    Gibby, Jacob T; Swenson, Samuel A; Cvetko, Steve; Rao, Raj; Javan, Ramin

    2018-06-22

    Augmented reality has potential to enhance surgical navigation and visualization. We determined whether head-mounted display augmented reality (HMD-AR) with superimposed computed tomography (CT) data could allow the wearer to percutaneously guide pedicle screw placement in an opaque lumbar model with no real-time fluoroscopic guidance. CT imaging was obtained of a phantom composed of L1-L3 Sawbones vertebrae in opaque silicone. Preprocedural planning was performed by creating virtual trajectories of appropriate angle and depth for ideal approach into the pedicle, and these data were integrated into the Microsoft HoloLens using the Novarad OpenSight application allowing the user to view the virtual trajectory guides and CT images superimposed on the phantom in two and three dimensions. Spinal needles were inserted following the virtual trajectories to the point of contact with bone. Repeat CT revealed actual needle trajectory, allowing comparison with the ideal preprocedural paths. Registration of AR to phantom showed a roughly circular deviation with maximum average radius of 2.5 mm. Users took an average of 200 s to place a needle. Extrapolation of needle trajectory into the pedicle showed that of 36 needles placed, 35 (97%) would have remained within the pedicles. Needles placed approximated a mean distance of 4.69 mm in the mediolateral direction and 4.48 mm in the craniocaudal direction from pedicle bone edge. To our knowledge, this is the first peer-reviewed report and evaluation of HMD-AR with superimposed 3D guidance utilizing CT for spinal pedicle guide placement for the purpose of cannulation without the use of fluoroscopy.

  4. Ischemic or toxic injury: A challenging diagnosis and treatment of drug-induced stenosis of the sigmoid colon.

    PubMed

    Zhang, Zong-Ming; Lin, Xiang-Chun; Ma, Li; Jin, An-Qin; Lin, Fang-Cai; Liu, Zhuo; Liu, Li-Min; Zhang, Chong; Zhang, Na; Huo, Li-Juan; Jiang, Xue-Liang; Kang, Feng; Qin, Hong-Jun; Li, Qiu-Yang; Yu, Hong-Wei; Deng, Hai; Zhu, Ming-Wen; Liu, Zi-Xu; Wan, Bai-Jiang; Yang, Hai-Yan; Liao, Jia-Hong; Luo, Xu; Li, You-Wei; Wei, Wen-Ping; Song, Meng-Meng; Zhao, Yue; Shi, Xue-Ying; Lu, Zhao-Hui

    2017-06-07

    A 48-year-old woman was admitted with 15-mo history of abdominal pain, diarrhea and hematochezia, and 5-mo history of defecation difficulty. She had been successively admitted to nine hospitals, with an initial diagnosis of inflammatory bowel disease with stenotic sigmoid colon. Findings from computed tomography virtual colonoscopy, radiography with meglumine diatrizoate, endoscopic balloon dilatation, metallic stent implantation and later overall colonoscopy, coupled with the newfound knowledge of compound Qingdai pill-taking, led to a subsequent diagnosis of ischemic or toxic bowel disease with sigmoid colon stenosis. The patient was successfully treated by laparoscopic sigmoid colectomy, and postoperative pathological examination revealed ischemic or toxic injury of the sigmoid colon, providing a final diagnosis of drug-induced sigmoid colon stenosis. This case highlights that adequate awareness of drug-induced colon stenosis has a decisive role in avoiding misdiagnosis and mistreatment. The diagnostic and therapeutic experiences learnt from this case suggest that endoscopic balloon expansion and colonic metallic stent implantation as bridge treatments were demonstrated as crucial for the differential diagnosis of benign colonic stenosis. Skillful surgical technique and appropriate perioperative management helped to ensure the safety of our patient in subsequent surgery after long-term use of glucocorticoids.

  5. Ischemic or toxic injury: A challenging diagnosis and treatment of drug-induced stenosis of the sigmoid colon

    PubMed Central

    Zhang, Zong-Ming; Lin, Xiang-Chun; Ma, Li; Jin, An-Qin; Lin, Fang-Cai; Liu, Zhuo; Liu, Li-Min; Zhang, Chong; Zhang, Na; Huo, Li-Juan; Jiang, Xue-Liang; Kang, Feng; Qin, Hong-Jun; Li, Qiu-Yang; Yu, Hong-Wei; Deng, Hai; Zhu, Ming-Wen; Liu, Zi-Xu; Wan, Bai-Jiang; Yang, Hai-Yan; Liao, Jia-Hong; Luo, Xu; Li, You-Wei; Wei, Wen-Ping; Song, Meng-Meng; Zhao, Yue; Shi, Xue-Ying; Lu, Zhao-Hui

    2017-01-01

    A 48-year-old woman was admitted with 15-mo history of abdominal pain, diarrhea and hematochezia, and 5-mo history of defecation difficulty. She had been successively admitted to nine hospitals, with an initial diagnosis of inflammatory bowel disease with stenotic sigmoid colon. Findings from computed tomography virtual colonoscopy, radiography with meglumine diatrizoate, endoscopic balloon dilatation, metallic stent implantation and later overall colonoscopy, coupled with the newfound knowledge of compound Qingdai pill-taking, led to a subsequent diagnosis of ischemic or toxic bowel disease with sigmoid colon stenosis. The patient was successfully treated by laparoscopic sigmoid colectomy, and postoperative pathological examination revealed ischemic or toxic injury of the sigmoid colon, providing a final diagnosis of drug-induced sigmoid colon stenosis. This case highlights that adequate awareness of drug-induced colon stenosis has a decisive role in avoiding misdiagnosis and mistreatment. The diagnostic and therapeutic experiences learnt from this case suggest that endoscopic balloon expansion and colonic metallic stent implantation as bridge treatments were demonstrated as crucial for the differential diagnosis of benign colonic stenosis. Skillful surgical technique and appropriate perioperative management helped to ensure the safety of our patient in subsequent surgery after long-term use of glucocorticoids. PMID:28638234

  6. Precision insertion of percutaneous sacroiliac screws using a novel augmented reality-based navigation system: a pilot study.

    PubMed

    Wang, Huixiang; Wang, Fang; Leong, Anthony Peng Yew; Xu, Lu; Chen, Xiaojun; Wang, Qiugen

    2016-09-01

    Augmented reality (AR) enables superimposition of virtual images onto the real world. The aim of this study is to present a novel AR-based navigation system for sacroiliac screw insertion and to evaluate its feasibility and accuracy in cadaveric experiments. Six cadavers with intact pelvises were employed in our study. They were CT scanned and the pelvis and vessels were segmented into 3D models. The ideal trajectory of the sacroiliac screw was planned and represented visually as a cylinder. For the intervention, the head mounted display created a real-time AR environment by superimposing the virtual 3D models onto the surgeon's field of view. The screws were drilled into the pelvis as guided by the trajectory represented by the cylinder. Following the intervention, a repeat CT scan was performed to evaluate the accuracy of the system, by assessing the screw positions and the deviations between the planned trajectories and inserted screws. Post-operative CT images showed that all 12 screws were correctly placed with no perforation. The mean deviation between the planned trajectories and the inserted screws was 2.7 ± 1.2 mm at the bony entry point, 3.7 ± 1.1 mm at the screw tip, and the mean angular deviation between the two trajectories was 2.9° ± 1.1°. The mean deviation at the nerve root tunnels region on the sagittal plane was 3.6 ± 1.0 mm. This study suggests an intuitive approach for guiding screw placement by way of AR-based navigation. This approach was feasible and accurate. It may serve as a valuable tool for assisting percutaneous sacroiliac screw insertion in live surgery.

  7. [Application of 3D virtual reality technology with multi-modality fusion in resection of glioma located in central sulcus region].

    PubMed

    Chen, T N; Yin, X T; Li, X G; Zhao, J; Wang, L; Mu, N; Ma, K; Huo, K; Liu, D; Gao, B Y; Feng, H; Li, F

    2018-05-08

    Objective: To explore the clinical and teaching application value of virtual reality technology in preoperative planning and intraoperative guide of glioma located in central sulcus region. Method: Ten patients with glioma in the central sulcus region were proposed to surgical treatment. The neuro-imaging data, including CT, CTA, DSA, MRI, fMRI were input to 3dgo sczhry workstation for image fusion and 3D reconstruction. Spatial relationships between the lesions and the surrounding structures on the virtual reality image were obtained. These images were applied to the operative approach design, operation process simulation, intraoperative auxiliary decision and the training of specialist physician. Results: Intraoperative founding of 10 patients were highly consistent with preoperative simulation with virtual reality technology. Preoperative 3D reconstruction virtual reality images improved the feasibility of operation planning and operation accuracy. This technology had not only shown the advantages for neurological function protection and lesion resection during surgery, but also improved the training efficiency and effectiveness of dedicated physician by turning the abstract comprehension to virtual reality. Conclusion: Image fusion and 3D reconstruction based virtual reality technology in glioma resection is helpful for formulating the operation plan, improving the operation safety, increasing the total resection rate, and facilitating the teaching and training of the specialist physician.

  8. CT Colonography with Computer-aided Detection: Recognizing the Causes of False-Positive Reader Results

    PubMed Central

    Dachman, Abraham H.; Wroblewski, Kristen; Vannier, Michael W.; Horne, John M.

    2014-01-01

    Computed tomography (CT) colonography is a screening modality used to detect colonic polyps before they progress to colorectal cancer. Computer-aided detection (CAD) is designed to decrease errors of detection by finding and displaying polyp candidates for evaluation by the reader. CT colonography CAD false-positive results are common and have numerous causes. The relative frequency of CAD false-positive results and their effect on reader performance on the basis of a 19-reader, 100-case trial shows that the vast majority of CAD false-positive results were dismissed by readers. Many CAD false-positive results are easily disregarded, including those that result from coarse mucosa, reconstruction, peristalsis, motion, streak artifacts, diverticulum, rectal tubes, and lipomas. CAD false-positive results caused by haustral folds, extracolonic candidates, diminutive lesions (<6 mm), anal papillae, internal hemorrhoids, varices, extrinsic compression, and flexural pseudotumors are almost always recognized and disregarded. The ileocecal valve and tagged stool are common sources of CAD false-positive results associated with reader false-positive results. Nondismissable CAD soft-tissue polyp candidates larger than 6 mm are another common cause of reader false-positive results that may lead to further evaluation with follow-up CT colonography or optical colonoscopy. Strategies for correctly evaluating CAD polyp candidates are important to avoid pitfalls from common sources of CAD false-positive results. ©RSNA, 2014 PMID:25384290

  9. Clinical Significance of Fluorine-18-fluorodeoxyglucose Positron Emission Tomography/computed Tomography in the Follow-up of Colorectal Cancer: Searching off Approaches Increasing Specificity for Detection of Recurrence

    PubMed Central

    Okuyucu, Kursat; Hancerliogulları, Oguz; Alagoz, Engin; San, Huseyin; Arslan, Nuri

    2017-01-01

    Abstract Background Nearly 40% of colorectal cancer (CRC) recurs within 2 years after resection of primary tumor. Imaging with fluorine-18-fluorodeoxyglucose (l8F-FDG) positron emission tomography/computed tomography (PET/CT) is the most recent modality and often applied for the evaluation of metastatic spread during the follow-up period. Our goal was to study the diagnostic importance of 18F-FDG-PET/CT data of maximum standardized uptake value (SUVmax), total lesion glycolysis (TLG) and the difference of SUVmax on dual-time imaging in CRC. Patients and methods We examined the SUVmax value of lesions on control or restaging 18F-FDG-PET/CT of 53 CRC patients. All lesions with increased SUVmax values were confirmed by colonoscopy or histopathology. We compared PET/CT results with conventional imaging modalities (CT, MRI) and tumor markers (carbohydrate antigen 19-9 [Ca 19-9], carcinoembryonic antigen [CEA]). Results Mean SUVmax was 6.9 ± 5.6 in benign group, 12.7 ± 6.1 in malignant group. Mean TLG values of malignant group and benign group were 401 and 148, respectively. 18F-FDG-PET/CT was truely positive in 48% of patients with normal Ca 19-9 or CEA levels and truely negative in 10% of cases with elevated Ca 19-9 or CEA. CT or MRI detected suspicious malignancy in 32% of the patients and 18F-FDG-PET/CT was truely negative in 35% of these cases. We found the most important and striking statistical difference of TLG value between the groups with benign and recurrent disease. Conclusions Although SUVmax is a strong metabolic parameter (p = 0.008), TLG seems to be the best predictor in recurrence of CRC (p = 0.001); both are increasing the specificity of 18F-FDG-PET/CT. PMID:29333115

  10. Clinical Significance of Fluorine-18-fluorodeoxyglucose Positron Emission Tomography/computed Tomography in the Follow-up of Colorectal Cancer: Searching off Approaches Increasing Specificity for Detection of Recurrence.

    PubMed

    Ince, Semra; Okuyucu, Kursat; Hancerliogulları, Oguz; Alagoz, Engin; San, Huseyin; Arslan, Nuri

    2017-12-01

    Nearly 40% of colorectal cancer (CRC) recurs within 2 years after resection of primary tumor. Imaging with fluorine-18-fluorodeoxyglucose ( l8 F-FDG) positron emission tomography/computed tomography (PET/CT) is the most recent modality and often applied for the evaluation of metastatic spread during the follow-up period. Our goal was to study the diagnostic importance of 18 F-FDG-PET/CT data of maximum standardized uptake value (SUVmax), total lesion glycolysis (TLG) and the difference of SUVmax on dual-time imaging in CRC. We examined the SUVmax value of lesions on control or restaging 18 F-FDG-PET/CT of 53 CRC patients. All lesions with increased SUVmax values were confirmed by colonoscopy or histopathology. We compared PET/CT results with conventional imaging modalities (CT, MRI) and tumor markers (carbohydrate antigen 19-9 [Ca 19-9], carcinoembryonic antigen [CEA]). Mean SUVmax was 6.9 ± 5.6 in benign group, 12.7 ± 6.1 in malignant group. Mean TLG values of malignant group and benign group were 401 and 148, respectively. 18 F-FDG-PET/CT was truely positive in 48% of patients with normal Ca 19-9 or CEA levels and truely negative in 10% of cases with elevated Ca 19-9 or CEA. CT or MRI detected suspicious malignancy in 32% of the patients and 18 F-FDG-PET/CT was truely negative in 35% of these cases. We found the most important and striking statistical difference of TLG value between the groups with benign and recurrent disease. Although SUVmax is a strong metabolic parameter (p = 0.008), TLG seems to be the best predictor in recurrence of CRC (p = 0.001); both are increasing the specificity of 18 F-FDG-PET/CT.

  11. An alternative option for "resect and discard" strategy, using magnifying narrow-band imaging: a prospective "proof-of-principle" study.

    PubMed

    Takeuchi, Yoji; Hanafusa, Masao; Kanzaki, Hiromitsu; Ohta, Takashi; Hanaoka, Noboru; Yamamoto, Sachiko; Higashino, Koji; Tomita, Yasuhiko; Uedo, Noriya; Ishihara, Ryu; Iishi, Hiroyasu

    2015-10-01

    The "resect and discard" strategy is beneficial for cost savings on screening and surveillance colonoscopy, but it has the risk to discard lesions with advanced histology or small invasive cancer (small advanced lesion; SALs). The aim of this study was to prove the principle of new "resect and discard" strategy with consideration for SALs using magnifying narrow-band imaging (M-NBI). Patients undergoing colonoscopy at a tertiary center were involved in this prospective trial. For each detected polyp <10 mm, optical diagnosis (OD) and virtual management ("leave in situ", "discard" or "send for pathology") were independently made using non-magnifying NBI (N-NBI) and M-NBI, and next surveillance interval were predicted. Histological and optical diagnosis results of all polyps were compared. While the management could be decided in 82% of polyps smaller than 10 mm, 24/31 (77%) SALs including two small invasive cancers were not discarded based on OD using M-NBI. The sensitivity [90% confidence interval (CI)] of M-NBI for SALs was 0.77 (0.61-0.89). The risk for discarding SALs using N-NBI was significantly higher than that using M-NBI (53 vs. 23%, p = 0.02). The diagnostic accuracy (95% CI) of M-NBI in distinguishing neoplastic from non-neoplastic lesions [0.88 (0.86-0.90)] was significantly better than that of N-NBI [0.84 (0.82-0.87)] (p = 0.005). The results of our study indicated that our "resect and discard" strategy using M-NBI could work to reduce the risk for discarding SALs including small invasive cancer (UMIN-CTR, UMIN000003740).

  12. Adenoma Detection Rate: I Will Show You Mine if You Show Me Yours

    PubMed Central

    Oliveira Ferreira, Alexandre; Fidalgo, Catarina; Palmela, Carolina; Costa Santos, Maria Pia; Torres, Joana; Nunes, Joana; Loureiro, Rui; Ferreira, Rosa; Barjas, Elídio; Glória, Luísa; Santos, António Alberto; Cravo, Marília

    2017-01-01

    Background Colorectal cancer (CRC) is the first cause of cancer-related mortality in Portugal. CRC screening reduces disease-specific mortality. Colonoscopy is currently the preferred method for screening as it may contribute to the reduction of CRC incidence. This beneficial effect is strongly associated with the adenoma detection rate (ADR). Aim Our aim was to evaluate the quality of colonoscopy at our unit by measuring the currently accepted quality parameters and publish them as benchmarking indicators. Methods From 5,860 colonoscopies, 654 screening procedures (with and without previous fecal occult blood testing) were analyzed. Results The mean age of the patients was 66.4 ± 7.8 years, and the gender distribution was 1:1. The overall ADR was 36% (95% confidence interval [CI] 32–39), the mean number of adenomas per colonoscopy was 0.66 (95% CI 0.56–0.77), and the sessile serrate lesion detection rate was 1% (95% CI 0–2). The bowel preparation was rated as adequate in 496 (76%) patients. The adjusted cecal intubation rate (CIR) was 93.7% (95% CI 91.7–95.8). Most colonoscopies were performed under monitored anesthesia care (53%), and 35% were unsedated. The use of sedation (propofol or midazolam based) was associated with a higher CIR with an odds ratio of 3.60 (95% CI 2.02–6.40, p < 0.001). Conclusion Our data show an above-standard ADR. The frequency of poor bowel preparation and the low sessile serrated lesion detection rate were acknowledged, and actions were implemented to improve both indicators. Quality auditing in colonoscopy should be compulsory, and while many units may do so internally, this is the first national report from a high-throughput endoscopy unit. PMID:28848785

  13. Colorectal cancer screening: results of a 5-year program in asymptomatic subjects at increased risk.

    PubMed

    Pezzoli, A; Matarese, V; Rubini, M; Simoni, M; Caravelli, G C; Stockbrugger, R; Cifalà, V; Boccia, S; Feo, C; Simone, L; Trevisani, L; Liboni, A; Gullini, S

    2007-01-01

    The province of Ferrara has one of the highest incidences of colorectal cancer (CRC) in Italy. In January 2000, we set up a colonoscopy screening program focussing on first-degree relatives of CRC patients. We now report the results 5 years after the beginning of the project. SCREENEES AND METHODS: In October 1999, we started a campaign stressing the usefulness of colonoscopy for the first-degree relatives of CRC patients. Subjects included in the screening program were aged between 45 and 75 years with at least one first-degree relative affected by CRC. They were invited to an interview where a physician suggested colonoscopy as a screening option. In 5 years, 776 subjects were interviewed and 733 (94.4%) agreed to an endoscopic examination (M/F:375/401; mean age 55 years): 562 colonoscopies were performed. Adenomas and cancers were found in 122 (21.7%) and 12 (2.1%) subjects, respectively. Histological examination in 181 persons with lesions (32.8%) showed (most serious lesion quoted) 47 hyperplastic polyps (26% of all lesions), 2 serrated adenomas (1.1%), 68 tubular adenomas (48%), 24 tubulovillous adenomas (13.3%), 9 adenomas with high grade dysplasia (5%) and 12 adenocarcinomas (6.6%). The majority of the cancers were at an early stage (8 Dukes A and 3 Dukes B). Sedation was used in only 42 colonoscopies (7.5%). A colonoscopy-based screening in this selected high-risk population is feasible. Even without sedation subjects readily agreed to the endoscopic procedure. We identified a significant number of advanced neoplasms and cancers at an early stage suggesting that this could be a useful tool in early identification of CRC.

  14. Cancer risk awareness and screening uptake in individuals at higher risk for colon cancer: a cross-sectional study.

    PubMed

    Salimzadeh, Hamideh; Bishehsari, Faraz; Delavari, Alireza; Barzin, Gilda; Amani, Mohammad; Majidi, Azam; Sadjadi, Alireza; Malekzadeh, Reza

    2016-12-20

    We aimed to measure cancer knowledge and feasibility of a screening colonoscopy among a cohort of individuals at higher risk of colon cancer. This study was conducted as part of an ongoing screening cohort, in which first degree relatives (FDRs) of patients with colon cancer are invited to participate in a free of charge screening colonoscopy. We enrolled 1017 FDRs in the study between 2013 and 2014 measuring their data on demographics, cancer knowledge and colonoscopy uptake. A p value of <0.05 was considered statistically significant. The relative's mean age was 48.7 years. Only about 28% of FDRs were aware of their increased risk for cancer, near 35.0% had ever heard about colonoscopy with 22% aware of the correct age to start screening. Comparing cancer knowledge of FDRs at high risk versus those at moderate risk, we recorded non-significant differences (p>0.05). Almost two-thirds of FDRs expressed willingness to undergo a colonoscopy and 49.2% completed the procedure, of which 12.8% had advanced neoplasm. Our data indicated that remarkable numbers of FDRs were not still informed of their cancer risk or never received a physician recommendation for screening. The desirable uptake at first invitation, which would be higher over successive invitations, supports the feasibility of a family-based recruitment approach for early screening. This has promising implications to introduce targeted screening colonoscopy into the healthcare system in Iran and other developing nations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. Rural Disparities in Treatment-Related Financial Hardship and Adherence to Surveillance Colonoscopy in Diverse Colorectal Cancer Survivors.

    PubMed

    McDougall, Jean A; Banegas, Matthew P; Wiggins, Charles L; Chiu, Vi K; Rajput, Ashwani; Kinney, Anita Y

    2018-03-28

    Cancer survivors increasingly report financial hardship as a consequence of the high cost of cancer care, yet the financial experience of rural cancer survivors remains largely unstudied. The purpose of this study was to investigate potential rural disparities in the likelihood of financial hardship and nonadherence to surveillance colonoscopy. Individuals diagnosed with localized or regional colorectal cancer (CRC) between 2004-2012 were ascertained by the population-based New Mexico Tumor Registry. Participants completed a mailed questionnaire or telephone survey about their CRC survivorship experience, including treatment-related financial hardship and receipt of surveillance colonoscopy. Multivariable logistic regression was used to estimate adjusted odds ratios (OR) and 95% confidence intervals (CI). Compared to urban CRC survivors (n=168), rural CRC survivors (n=109) were slightly older, more likely to be married (65% v. 59%) and have an annual income <$30,000 (37% v. 27%), less likely to be employed (35% v. 41%), have a college degree (28% v. 38%) or a high level of health literacy (39% v. 51%). Rural survivors were twice as likely as urban survivors to report treatment-related financial hardship (OR 1.86, 95% CI 1.06-3.28) and nonadherence to surveillance colonoscopy guidelines (OR 2.28, 95% CI 1.07-4.85). In addition, financial hardship was independently associated with nonadherence to surveillance colonoscopy (OR 2.17, 95% CI 1.01-4.85). Substantial rural disparities in the likelihood of financial hardship and nonadherence to surveillance colonoscopy exist. Treatment-related financial hardship among rural CRC survivors may negatively impact adherence to guideline recommended follow-up care. Copyright ©2018, American Association for Cancer Research.

  16. An Automated Inpatient Split-dose Bowel Preparation System Improves Colonoscopy Quality and Reduces Repeat Procedures.

    PubMed

    Yadlapati, Rena; Johnston, Elyse R; Gluskin, Adam B; Gregory, Dyanna L; Cyrus, Rachel; Werth, Lindsay; Ciolino, Jody D; Grande, David P; Keswani, Rajesh N

    2017-07-19

    Inpatient colonoscopy preparations are often inadequate, compromising patient safety and procedure quality, while resulting in greater hospital costs. The aims of this study were to: (1) design and implement an electronic inpatient split-dose bowel preparation order set; (2) assess the intervention's impact upon preparation adequacy, repeated colonoscopies, hospital days, and costs. We conducted a single center prospective pragmatic quasiexperimental study of hospitalized adults undergoing colonoscopy. The experimental intervention was designed using DMAIC (define, measure, analyze, improve, and control) methodology. Prospective data collected over 12 months were compared with data from a historical preintervention cohort. The primary outcome was bowel preparation quality and secondary outcomes included number of repeated procedures, hospital days, and costs. On the basis of a Delphi method and DMAIC process, we created an electronic inpatient bowel preparation order set inclusive of a split-dose bowel preparation algorithm, automated orders for rescue medications, and nursing bowel preparation checks. The analysis data set included 969 patients, 445 (46%) in the postintervention group. The adequacy of bowel preparation significantly increased following intervention (86% vs. 43%; P<0.01) and proportion of repeated procedures decreased (2.0% vs. 4.6%; P=0.03). Mean hospital days from bowel preparation initiation to discharge decreased from 8.0 to 6.9 days (P=0.02). The intervention resulted in an estimated 1-year cost-savings of $46,076 based on a reduction in excess hospital days associated with repeated and delayed procedures. Our interdisciplinary initiative targeting inpatient colonoscopy preparations significantly improved quality and reduced repeat procedures, and hospital days. Other institutions should consider utilizing this framework to improve inpatient colonoscopy value.

  17. Utilization of Surveillance after Polypectomy in the Medicare Population – A Cohort Study

    PubMed Central

    Lansdorp-Vogelaar, Iris; Fedewa, Stacey; Lin, Chun Chieh; Virgo, Katherine S.; Jemal, Ahmedin

    2014-01-01

    Background Surveillance in patients with previous polypectomy was underused in the Medicare population in 1994. This study investigates whether expansion of Medicare reimbursement for colonoscopy screening in high-risk individuals has reduced the inappropriate use of surveillance. Methods We used Kaplan-Meier analysis to estimate time to surveillance and polyp recurrence rates for Medicare beneficiaries with a colonoscopy with polypectomy between 1998 and 2003 who were followed through 2008 for receipt of surveillance colonoscopy. Generalized Estimating Equations were used to estimate risk factors for: 1) failing to undergo surveillance and 2) polyp recurrence among these individuals. Analyses were stratified into three 2-year cohorts based on baseline colonoscopy date. Results Medicare beneficiaries undergoing a colonoscopy with polypectomy in the 1998–1999 (n = 4,136), 2000–2001 (n = 3,538) and 2002–2003 (n = 4,655) cohorts had respective probabilities of 30%, 26% and 20% (p<0.001) of subsequent surveillance events within 3 years. At the same time, 58%, 52% and 45% (p<0.001) of beneficiaries received a surveillance event within 5 years. Polyp recurrence rates after 5 years were 36%, 30% and 26% (p<0.001) respectively. Older age (≥ 70 years), female gender, later cohort (2000–2001 & 2002–2003), and severe comorbidity were the most important risk factors for failure to undergo a surveillance event. Male gender and early cohort (1998–1999) were the most important risk factors for polyp recurrence. Conclusions Expansion of Medicare reimbursement for colonoscopy screening in high-risk individuals has not reduced underutilization of surveillance in the Medicare population. It is important to take action now to improve this situation, because polyp recurrence is substantial in this population. PMID:25393312

  18. Adenoma Detection Rates for Screening Colonoscopies in Smokers and Obese Adults: Data From the New Hampshire Colonoscopy Registry.

    PubMed

    Anderson, Joseph C; Weiss, Julia E; Robinson, Christina M; Butterly, Lynn F

    To examine screening adenoma detection rates (ADR) and serrated detection rates (SDR) among smokers and obese adults in the New Hampshire Colonoscopy Registry. ADR, a quality measure for screening colonoscopies, is associated with protection from interval colorectal cancer. Currently, only sex-specific ADR benchmarks are reported. However, obesity and smoking ≥20 pack-years are strong predictors for colorectal neoplasia, as highlighted by the 2009 American College of Gastroenterology CRC Screening Guidelines. Data comparing ADR in smokers and obese adults to those without these risks are limited. We calculated ADR, SDR, and 95% confidence intervals for screening colonoscopies in participants ≥50 years. Sex-specific and sex-age-specific rates were compared by smoking exposure (never vs. <20 vs. ≥20 pack-years) and body mass index (<30 vs. ≥30). A total of 21,539 screening colonoscopies were performed by 77 endoscopists at 20 facilities (April 2009 to September 2013). The difference in ADR between nonsmokers and smokers with ≥20 pack-years was 8.8% (P<0.0001) and between obesity groups 5.0% (P<0.0001). Significant sex-specific and sex-age-specific increases in ADR and SDR were found among smokers and obese participants. ADR and SDR for smokers and obese adults were significantly higher than their counterparts without those risks. Endoscopists should consider the prevalence of these risks within their screening population when comparing their rates to established benchmarks. Calculating sex-specific or sex-age-specific ADR and SDR based on smoking and obesity may provide optimal protection for populations with a particularly high prevalence of smokers and obese adults.

  19. Virtual monochromatic spectral imaging with fast kilovoltage switching: reduction of metal artifacts at CT.

    PubMed

    Pessis, Eric; Campagna, Raphaël; Sverzut, Jean-Michel; Bach, Fabienne; Rodallec, Mathieu; Guerini, Henri; Feydy, Antoine; Drapé, Jean-Luc

    2013-01-01

    With arthroplasty being increasingly used to relieve joint pain, imaging of patients with metal implants can represent a significant part of the clinical work load in the radiologist's daily practice. Computed tomography (CT) plays an important role in the postoperative evaluation of patients who are suspected of having metal prosthesis-related problems such as aseptic loosening, bone resorption or osteolysis, infection, dislocation, metal hardware failure, or periprosthetic bone fracture. Despite advances in detector technology and computer software, artifacts from metal implants can seriously degrade the quality of CT images, sometimes to the point of making them diagnostically unusable. Several factors may help reduce the number and severity of artifacts at multidetector CT, including decreasing the detector collimation and pitch, increasing the kilovolt peak and tube charge, and using appropriate reconstruction algorithms and section thickness. More recently, dual-energy CT has been proposed as a means of reducing beam-hardening artifacts. The use of dual-energy CT scanners allows the synthesis of virtual monochromatic spectral (VMS) images. Monochromatic images depict how the imaged object would look if the x-ray source produced x-ray photons at only a single energy level. For this reason, VMS imaging is expected to provide improved image quality by reducing beam-hardening artifacts.

  20. Creation of virtual patients from CT images of cadavers to enhance integration of clinical and basic science student learning in anatomy.

    PubMed

    Jacobson, Stanley; Epstein, Scott K; Albright, Susan; Ochieng, Joseph; Griffiths, Jeffrey; Coppersmith, Veronica; Polak, Joseph F

    2009-08-01

    The goal of this study was to determine whether computerized tomographic (CT) images of cadavers could be used in addition to images from patients to develop virtual patients (VPs) to enhance integrated learning of basic and clinical science. We imaged 13 cadavers on a Siemens CT system. The DICOM images from the CT were noted to be of high quality by a radiologist who systematically identified all abnormal and pathological findings. The pathological findings from the CT images and the cause of death were used to develop plausible clinical cases and study questions. Each case was designed to highlight and explain the abnormal anatomic findings encountered during the cadaveric dissection. A 3D reconstruction was produced using OsiriX and then formatted into a QuickTime movie which was then stored on the Tufts University Sciences Knowledgebase (TUSK) as a VP. We conclude that CT scanning of cadavers produces high-quality images that can be used to develop VPs. Although the use of the VPs was optional and fewer than half of the students had an imaged cadaver for dissection, 59 of the 172 (34%) students accessed and reviewed the cases and images positively and were very encouraging for us to continue.

  1. Patient-specific instrument can achieve same accuracy with less resection time than navigation assistance in periacetabular pelvic tumor surgery: a cadaveric study.

    PubMed

    Wong, Kwok-Chuen; Sze, Kwan-Yik; Wong, Irene Oi-Ling; Wong, Chung-Ming; Kumta, Shekhar-Madhukar

    2016-02-01

    Inaccurate resection in pelvic tumors can result in compromised margins with increase local recurrence. Navigation-assisted and patient-specific instrument (PSI) techniques have recently been reported in assisting pelvic tumor surgery with the tendency of improving surgical accuracy. We examined and compared the accuracy of transferring a virtual pelvic resection plan to actual surgery using navigation-assisted or PSI technique in a cadaver study. We performed CT scan in twelve cadaveric bodies including whole pelvic bones. Either supraacetabular or partial acetabular resection was virtually planned in a hemipelvis using engineering software. The virtual resection plan was transferred to a CT-based navigation system or was used for design and fabrication of PSI. Pelvic resections were performed using navigation assistance in six cadavers and PSI in another six. Post-resection images were co-registered with preoperative planning for comparative analysis of resection accuracy in the two techniques. The mean average deviation error from the planned resection was no different ([Formula: see text]) for the navigation and the PSI groups: 1.9 versus 1.4 mm, respectively. The mean time required for the bone resection was greater ([Formula: see text]) for the navigation group than for the PSI group: 16.2 versus 1.1 min, respectively. In simulated periacetabular pelvic tumor resections, PSI technique enabled surgeons to reproduce the virtual surgical plan with similar accuracy but with less bone resection time when compared with navigation assistance. Further studies are required to investigate the clinical benefits of PSI technique in pelvic tumor surgery.

  2. Next-generation narrow band imaging system for colonic polyp detection: a prospective multicenter randomized trial.

    PubMed

    Horimatsu, Takahiro; Sano, Yasushi; Tanaka, Shinji; Kawamura, Takuji; Saito, Shoichi; Iwatate, Mineo; Oka, Shiro; Uno, Koji; Yoshimura, Kenichi; Ishikawa, Hideki; Muto, Manabu; Tajiri, Hisao

    2015-07-01

    Previous studies have yielded conflicting results on the colonic polyp detection rate with narrow-band imaging (NBI) compared with white-light imaging (WLI). We compared the mean number of colonic polyps detected per patient for NBI versus WLI using a next-generation NBI system (EVIS LUCERA ELITE; Olympus Medical Systems) used with standard-definition (SD) colonoscopy and wide-angle (WA) colonoscopy. this study is a 2 × 2 factorial, prospective, multicenter randomized controlled trial. this study was conducted at five academic centers in Japan. patients were allocated to one of four groups: (1) WLI with SD colonoscopy (H260AZI), (2) NBI with SD colonoscopy (H260AZI), (3) WLI with WA colonoscopy (CF-HQ290), and (4) NBI with WA colonoscopy (CF-HQ290). the mean numbers of polyps detected per patient were compared between the four groups: WLI with/without WA colonoscopy and NBI with/without WA colonoscopy. Of the 454 patients recruited, 431 patients were enrolled. The total numbers of polyps detected by WLI with SD, NBI with SD, WLI with WA, and NBI with WA were 164, 176, 188, and 241, respectively. The mean number of polyps detected per patient was significantly higher in the NBI group than in the WLI group (2.01 vs 1.56; P = 0.032). The rate was not higher in the WA group than in the SD group (1.97 vs 1.61; P = 0.089). Although WA colonoscopy did not improve the polyp detection, next-generation NBI colonoscopy represents a significant improvement in the detection of colonic polyps.

  3. Patients with History of Colonoscopy Are Less Likely to Achieve High Quality Preparation After Implementing Split-Dose Bowel Preparation.

    PubMed

    Madhoun, M F; Bitar, H; Parava, P; Bashir, M H; Zia, H

    2017-01-01

    Anecdotally, we observed that patients who had previous colonoscopies were less likely to follow newly implemented split-dose bowel preparation (SDBP) instructions. We investigated whether the indication for colonoscopy is an independent factor for achieving high quality bowel preparation among patients asked to follow SDBP. We performed a retrospective study of data from 1478 patients who received outpatient colonoscopies in 2014 (the year of SDBP implementation) at our Veterans Affairs Medical Center. We collected information related to demographics and factors known to affect bowel preparations. Reasons for colonoscopy were dichotomized into surveillance (previous colonoscopy) vs. non-surveillance (positive occult blood test or screening). Bowel preparation quality was scored using the Boston Bowel Preparation Scale (BBPS), and was categorized as either excellent vs. not excellent (BBPS≥7 vs. BBPS<7), or adequate vs. inadequate (BBPS≥6 vs. BBPS<6). Bowel preparation quality was excellent in 60% of colonoscopies and adequate in 84% of colonoscopies. Thirty-six percent (535) were surveillance colonoscopies. In multivariate logistic regression analysis, more patients in the non-surveillance group achieved excellent (OR 0.8 ; 95% CI [0.7-0.8], P <0.0001) and adequate (OR 0.8 ; 95% CI [0.7-0.9], P <0.006) bowel preparation than did patients in the surveillance group. Patients with a prior colonoscopy might not follow the split-dose bowel preparation instructions. Educational interventions emphasizing the benefits of SDBP in this group of patients may help ensure compliance and prevent the habitual use of day-before preparations. © Acta Gastro-Enterologica Belgica.

  4. Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note.

    PubMed

    Satarasinghe, Praveen; Hamilton, Kojo D; Tarver, Michael J; Buchanan, Robert J; Koltz, Michael T

    2018-04-17

    Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted virtual neuronavigation improves the precision of PS placement and minimization steps. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. (1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at an anatomical entry point with a screen projection showing a virtual screw. (2) A Navigated Stryker Cordless Driver with an appropriate tap was used to access the vertebral body through a pedicle with a screen projection again showing a virtual screw. (3) A Navigated Stryker Cordless Driver with an actual screw was used with a screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images taken to confirm hardware placement. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.

  5. Examining the Impact of Latino Nativity, Migration, and Acculturation Factors on Colonoscopy Screening.

    PubMed

    Costas-Muñiz, Rosario; Jandorf, Lina; Philip, Errol; Cohen, Noah; Villagra, Cristina; Sriphanlop, Pathu; Schofield, Elizabeth; DuHamel, Katherine

    2016-10-01

    Latinos are a diverse population comprised of multiple countries of origin with varying cultural profiles. This study examines differences in colonoscopy completion across place of birth and migration-related factors in a sample of predominantly Dominican and Puerto Rican Latinos living in New York City after receiving a recommendation for colonoscopy screening and navigation services. The sample included 702 Latinos recruited for two cancer screening projects targeting Latinos eligible for colonoscopy who seek healthcare in New York City. Participants completed a survey that included sociodemographic, health-related questions, psychosocial assessments and cancer screening practices, in Spanish or English. Migration, acculturation, and language factors were found to predict colonoscopy completion. The results indicated that Latinos born in the Dominican Republic and Central America were more likely to complete a screening colonoscopy than their counterparts born in the US. Further, those who emigrated at an older age, who have resided in the US for less than 20 years, preferred Spanish and those with lower US acculturation levels were also more likely to complete a screening colonoscopy. The findings suggest that Latinos who are less acculturated to the US are more likely to complete a screening colonoscopy after receiving a physician recommendation for colonoscopy screening. The results provide important information that can inform clinical practice and public health interventions. Continued attention to cultural and migration influences are important areas for cancer screening intervention development.

  6. Culturally targeted patient navigation for increasing african americans' adherence to screening colonoscopy: a randomized clinical trial.

    PubMed

    Jandorf, Lina; Braschi, Caitlyn; Ernstoff, Elizabeth; Wong, Carrie R; Thelemaque, Linda; Winkel, Gary; Thompson, Hayley S; Redd, William H; Itzkowitz, Steven H

    2013-09-01

    Patient navigation has been an effective intervention to increase cancer screening rates. This study focuses on predicting outcomes of screening colonoscopy for colorectal cancer among African Americans using different patient navigation formats. In a randomized clinical trial, patients more than 50 years of age without significant comorbidities were randomized into three navigation groups: peer-patient navigation (n = 181), pro-patient navigation (n = 123), and standard (n = 46). Pro-patient navigations were health care professionals who conducted culturally targeted navigation, whereas peer-patient navigations were community members trained in patient navigation who also discussed their personal experiences with screening colonoscopy. Two assessments gathered sociodemographic, medical, and intrapersonal information. Screening colonoscopy completion rate was 75.7% across all groups with no significant differences in completion between the three study arms. Annual income more than $10,000 was an independent predictor of screening colonoscopy adherence. Unexpectedly, low social influence also predicted screening colonoscopy completion. In an urban African American population, patient navigation was effective in increasing screening colonoscopy rates to 15% above the national average, regardless of patient navigation type or content. Because patient navigation successfully increases colonoscopy adherence, cultural targeting may not be necessary in some populations.

  7. Cultural, economic, and psychological predictors of colonoscopy in a national sample.

    PubMed

    Halbert, Chanita Hughes; Barg, Frances K; Guerra, Carmen E; Shea, Judy A; Armstrong, Katrina; Ferguson, Monica; Weathers, Benita; Coyne, James; Troxel, Andrea B

    2011-11-01

    Although colorectal cancer (CRC) is the second leading cause of cancer death among adults in the US and colonoscopy is efficacious in reducing morbidity and mortality from CRC, screening rates are sub-optimal. Understanding the socioeconomic, cultural, and health care context within which decisions about colonoscopy are made allows physicians to address patients' most salient beliefs and values and other constraints when making screening recommendations. To evaluate the direct and interactive effects of socioeconomics, health care variables, psychological characteristics, and cultural values on colonoscopy use. National survey completed between January-August 2009 in a random sample of African American, white, and Hispanic adults ages 50-75 without cancer (n = 582). Self-reported colonoscopy use. Only 59% of respondents reported having a colonoscopy. The likelihood of colonoscopy increased with having health insurance (OR = 2.82, 95% CI = 1.24, 6.43, p = 0.004), and increasing age (OR = 1.40, 95% CI = 1.11, 1.77, p = 0.001). In addition, respondents with greater self-efficacy were more likely to have a colonoscopy (OR = 2.41, 95% CI = 1.35, 4.29, p = 0.003). Programs that help patients to overcome access and psychological barriers to screening are needed.

  8. Deep learning of contrast-coated serrated polyps for computer-aided detection in CT colonography

    NASA Astrophysics Data System (ADS)

    Näppi, Janne J.; Pickhardt, Perry; Kim, David H.; Hironaka, Toru; Yoshida, Hiroyuki

    2017-03-01

    Serrated polyps were previously believed to be benign lesions with no cancer potential. However, recent studies have revealed a novel molecular pathway where also serrated polyps can develop into colorectal cancer. CT colonography (CTC) can detect serrated polyps using the radiomic biomarker of contrast coating, but this requires expertise from the reader and current computer-aided detection (CADe) systems have not been designed to detect the contrast coating. The purpose of this study was to develop a novel CADe method that makes use of deep learning to detect serrated polyps based on their contrast-coating biomarker in CTC. In the method, volumetric shape-based features are used to detect polyp sites over soft-tissue and fecal-tagging surfaces of the colon. The detected sites are imaged using multi-angular 2D image patches. A deep convolutional neural network (DCNN) is used to review the image patches for the presence of polyps. The DCNN-based polyp-likelihood estimates are merged into an aggregate likelihood index where highest values indicate the presence of a polyp. For pilot evaluation, the proposed DCNN-CADe method was evaluated with a 10-fold cross-validation scheme using 101 colonoscopy-confirmed cases with 144 biopsy-confirmed serrated polyps from a CTC screening program, where the patients had been prepared for CTC with saline laxative and fecal tagging by barium and iodine-based diatrizoate. The average per-polyp sensitivity for serrated polyps >=6 mm in size was 93+/-7% at 0:8+/-1:8 false positives per patient on average. The detection accuracy was substantially higher that of a conventional CADe system. Our results indicate that serrated polyps can be detected automatically at high accuracy in CTC.

  9. Motivational interviewing and screening colonoscopy in high-risk individuals. A randomized controlled trial.

    PubMed

    Salimzadeh, Hamideh; Khabiri, Roghaye; Khazaee-Pool, Maryam; Salimzadeh, Somayeh; Delavari, Alireza

    2018-06-01

    To measure the impact of motivational interviewing (MI) on cancer knowledge and screening practice among first degree relatives (FDRs) of patients with colon cancer. This randomized controlled trial targeted patients with colon cancer first to recruit their possible FDRs. Digit randomization of the eligible index patients into intervention or control groups resulted in allocating their belonging FDRs to the same study arm. FDRs (n = 120) in intervention arm received MI counseling on phone by a trained oncology nurse and FDRs (n = 120) in control group received standard generic information by a physician on phone. Primary outcome was the rate of documented colonoscopy in FDRs within six months after the baseline. A total of 227 FDRs were followed up, 115 in the intervention and 112 in the control group. At follow-up, the uptake of screening colonoscopy in the intervention group was 83.5% versus 48.2% in controls (crude odds ratio, 5.4; 95% confidence interval, 2.9-10.0, P < .001). This was the first randomized controlled trial in Iran that confirmed the efficaciousness of a phone-based MI counseling in improving colonoscopy uptake among family members of patients with colon cancer. Phone-based motivational counseling that involves trained nurses or health providers seems to be feasible approach in Iran health system and enhances screening for colon cancer. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Cell-surface markers for colon adenoma and adenocarcinoma

    PubMed Central

    Sewda, Kamini; Coppola, Domenico; Enkemann, Steven; Yue, Binglin; Kim, Jongphil; Lopez, Alexis S.; Wojtkowiak, Jonathan W.; Stark, Valerie E.; Morse, Brian; Shibata, David; Vignesh, Shivakumar; Morse, David L.

    2016-01-01

    Early detection of colorectal cancer (CRC) is crucial for effective treatment. Among CRC screening techniques, optical colonoscopy is widely considered the gold standard. However, it is a costly and invasive procedure with a low rate of compliance. Our long-term goal is to develop molecular imaging agents for the non-invasive detection of CRC by molecular imaging-based colonoscopy using CT, MRI or fluorescence. To achieve this, cell surface targets must be identified and validated. Here, we report the discovery of cell-surface markers that distinguish CRC from surrounding tissues that could be used as molecular imaging targets. Profiling of mRNA expression microarray data from patient tissues including adenoma, adenocarcinoma, and normal gastrointestinal tissues was used to identify potential CRC specific cell-surface markers. Of the identified markers, six were selected for further validation (CLDN1, GPR56, GRM8, LY6G6D/F, SLCO1B3 and TLR4). Protein expression was confirmed by immunohistochemistry of patient tissues. Except for SLCO1B3, diffuse and low expression was observed for each marker in normal colon tissues. The three markers with the greatest protein overexpression were CLDN1, LY6G6D/F and TLR4, where at least one of these markers was overexpressed in 97% of the CRC samples. GPR56, LY6G6D/F and SLCO1B3 protein expression was significantly correlated with the proximal tumor location and with expression of mismatch repair genes. Marker expression was further validated in CRC cell lines. Hence, three cell-surface markers were discovered that distinguish CRC from surrounding normal tissues. These markers can be used to develop imaging or therapeutic agents targeted to the luminal surface of CRC. PMID:26894861

  11. Cell-surface markers for colon adenoma and adenocarcinoma.

    PubMed

    Sewda, Kamini; Coppola, Domenico; Enkemann, Steven; Yue, Binglin; Kim, Jongphil; Lopez, Alexis S; Wojtkowiak, Jonathan W; Stark, Valerie E; Morse, Brian; Shibata, David; Vignesh, Shivakumar; Morse, David L

    2016-04-05

    Early detection of colorectal cancer (CRC) is crucial for effective treatment. Among CRC screening techniques, optical colonoscopy is widely considered the gold standard. However, it is a costly and invasive procedure with a low rate of compliance. Our long-term goal is to develop molecular imaging agents for the non-invasive detection of CRC by molecular imaging-based colonoscopy using CT, MRI or fluorescence. To achieve this, cell surface targets must be identified and validated. Here, we report the discovery of cell-surface markers that distinguish CRC from surrounding tissues that could be used as molecular imaging targets. Profiling of mRNA expression microarray data from patient tissues including adenoma, adenocarcinoma, and normal gastrointestinal tissues was used to identify potential CRC specific cell-surface markers. Of the identified markers, six were selected for further validation (CLDN1, GPR56, GRM8, LY6G6D/F, SLCO1B3 and TLR4). Protein expression was confirmed by immunohistochemistry of patient tissues. Except for SLCO1B3, diffuse and low expression was observed for each marker in normal colon tissues. The three markers with the greatest protein overexpression were CLDN1, LY6G6D/F and TLR4, where at least one of these markers was overexpressed in 97% of the CRC samples. GPR56, LY6G6D/F and SLCO1B3 protein expression was significantly correlated with the proximal tumor location and with expression of mismatch repair genes. Marker expression was further validated in CRC cell lines. Hence, three cell-surface markers were discovered that distinguish CRC from surrounding normal tissues. These markers can be used to develop imaging or therapeutic agents targeted to the luminal surface of CRC.

  12. Spontaneous intramural hematoma of the colon.

    PubMed

    Fernandes, Samuel; Gonçalves, Ana Rita; Araújo Correia, Luís

    2016-08-01

    A 73-year-old man was admitted to our clinic with sudden left quadrant abdominal pain and hematochezia. There was no history of trauma. He denied other symptoms or taking off-the-counter medication. His medical history was relevant for ischemic and aortic-mitral valve disease with prosthetic valves for which he was medicated with aspirin and warfarin. On physical examination the patient presented normal vital signs with tenderness on palpation of the left side of the abdomen. Laboratory tests revealed moderate anemia (10.8 g/dl) and thrombocytopenia (135.000x10^9 U/L) with therapeutic international normalized ratio (2.53). Colonoscopy revealed an extensive area of erythematous and bluish mucosa with an apparent torsion of the proximal descending colon around a volumous hematoma measuring 6.5x3 cm (Figure 1 A-C). Urgent abdominal CT confirmed the presence of a large intramural hematoma of the descending colon (Figure 2 A-B). A conservative approach was adopted with temporary suspension of anticoagulation. Given the high thrombotic risk, abdominal ultrasound was performed after 72 hours showing considerable reduction in the size of the hematoma. Anti-coagulation was then resumed without complications. One month later, colonoscopy was repeated showing complete healing of the mucosa. The increasing use of anti-aggregating and anti-coagulant therapy, especially in elderly patients, explains the increasing incidence of bleeding events seen in this population. However, gastrointestinal hematomas are estimated to occur in only 1 for every 250.000 anti-coagulated patients. Diagnosis is based on characteristic radiologic findings. While most parietal hematomas can be approached conservatively, surgery is indicated in the presence of complications or persistence of the hematoma.

  13. Chronic methadone use, poor bowel visualization and failed colonoscopy: A preliminary study

    PubMed Central

    Verma, Siddharth; Fogel, Joshua; Beyda, David J; Bernstein, Brett; Notar-Francesco, Vincent; Mohanty, Smruti R

    2012-01-01

    AIM: To examine effects of chronic methadone usage on bowel visualization, preparation, and repeat colonoscopy. METHODS: In-patient colonoscopy reports from October, 2004 to May, 2009 for methadone dependent (MD) patients were retrospectively evaluated and compared to matched opioid naive controls (C). Strict criteria were applied to exclude patients with risk factors known to cause constipation or gastric dysmotility. Colonoscopy reports of all eligible patients were analyzed for degree of bowel visualization, assessment of bowel preparation (good, fair, or poor), and whether a repeat colonoscopy was required. Bowel visualization was scored on a 4 point scale based on multiple prior studies: excellent = 1, good = 2, fair = 3, or poor = 4. Analysis of variance (ANOVA) and Pearson χ2 test were used for data analyses. Subgroup analysis included correlation between methadone dose and colonoscopy outcomes. All variables significantly differing between MD and C groups were included in both univariate and multivariate logistic regression analyses. P values were two sided, and < 0.05 were considered statistically significant. RESULTS: After applying exclusionary criteria, a total of 178 MD patients and 115 C patients underwent a colonoscopy during the designated study period. A total of 67 colonoscopy reports for MD patients and 72 for C were included for data analysis. Age and gender matched controls were randomly selected from this population to serve as controls in a numerically comparable group. The average age for MD patients was 52.2 ± 9.2 years (range: 32-72 years) years compared to 54.6 ± 15.5 years (range: 20-81 years) for C (P = 0.27). Sixty nine percent of patients in MD and 65% in C group were males (P = 0.67). When evaluating colonoscopy reports for bowel visualization, MD patients had significantly greater percentage of solid stool (i.e., poor visualization) compared to C (40.3% vs 6.9%, P < 0.001). Poor bowel preparation (35.8% vs 9.7%, P < 0.001) and need for repeat colonoscopy (32.8% vs 12.5%, P = 0.004) were significantly higher in MD group compared to C, respectively. Under univariate analysis, factors significantly associated with MD group were presence of fecal particulate [odds ratio (OR), 3.89, 95% CI: 1.33-11.36, P = 0.01] and solid stool (OR, 13.5, 95% CI: 4.21-43.31, P < 0.001). Fair (OR, 3.82, 95% CI: 1.63-8.96, P = 0.002) and poor (OR, 8.10, 95% CI: 3.05-21.56, P < 0.001) assessment of bowel preparation were more likely to be associated with MD patients. Requirement for repeat colonoscopy was also significant higher in MD group (OR, 3.42, 95% CI: 1.44-8.13, P = 0.01). In the multivariate analyses, the only variable independently associated with MD group was presence of solid stool (OR, 7.77, 95% CI: 1.66-36.47, P = 0.01). Subgroup analysis demonstrated a general trend towards poorer bowel visualization with higher methadone dosage. ANOVA analysis demonstrated that mean methadone dose associated with presence of solid stool (poor visualization) was significantly higher compared to mean dosage for clean colon (excellent visualization, P = 0.02) or for those with liquid stool only (good visualization, P = 0.01). CONCLUSION: Methadone dependence is a risk factor for poor bowel visualization and leads to more repeat colonoscopies. More aggressive bowel preparation may be needed in MD patients. PMID:22969198

  14. Medical image retrieval system using multiple features from 3D ROIs

    NASA Astrophysics Data System (ADS)

    Lu, Hongbing; Wang, Weiwei; Liao, Qimei; Zhang, Guopeng; Zhou, Zhiming

    2012-02-01

    Compared to a retrieval using global image features, features extracted from regions of interest (ROIs) that reflect distribution patterns of abnormalities would benefit more for content-based medical image retrieval (CBMIR) systems. Currently, most CBMIR systems have been designed for 2D ROIs, which cannot reflect 3D anatomical features and region distribution of lesions comprehensively. To further improve the accuracy of image retrieval, we proposed a retrieval method with 3D features including both geometric features such as Shape Index (SI) and Curvedness (CV) and texture features derived from 3D Gray Level Co-occurrence Matrix, which were extracted from 3D ROIs, based on our previous 2D medical images retrieval system. The system was evaluated with 20 volume CT datasets for colon polyp detection. Preliminary experiments indicated that the integration of morphological features with texture features could improve retrieval performance greatly. The retrieval result using features extracted from 3D ROIs accorded better with the diagnosis from optical colonoscopy than that based on features from 2D ROIs. With the test database of images, the average accuracy rate for 3D retrieval method was 76.6%, indicating its potential value in clinical application.

  15. Colonic gas explosion during therapeutic colonoscopy with electrocautery

    PubMed Central

    Ladas, Spiros D; Karamanolis, George; Ben-Soussan, Emmanuel

    2007-01-01

    Therapeutic colonoscopy with electrocautery is widely used around the world. Adequate colonic cleansing is considered a crucial factor for the safety of this procedure. Colonic gas explosion, although rare, is one of the most frightening iatrogenic complications during colonoscopy with electrocautery. This complication is the result of an accumulation of colonic gases to explosive concentrations, but may be prevented by meticulous bowel preparation. The purpose of this review is to discuss the indications and the types of bowel preparations for therapeutic colonoscopy, and to contribute recommendations for the adequate bowel preparation for colonoscopy with electrocautery. PMID:17879396

  16. Differences in Colonoscopy Quality Among Facilities: Development of a Post-Colonoscopy Risk-Standardized Rate of Unplanned Hospital Visits.

    PubMed

    Ranasinghe, Isuru; Parzynski, Craig S; Searfoss, Rana; Montague, Julia; Lin, Zhenqiu; Allen, John; Vender, Ronald; Bhat, Kanchana; Ross, Joseph S; Bernheim, Susannah; Krumholz, Harlan M; Drye, Elizabeth E

    2016-01-01

    Colonoscopy is a common procedure, yet little is known about variations in colonoscopy quality among outpatient facilities. We developed an outcome measure to profile outpatient facilities by estimating risk-standardized rates of unplanned hospital visits within 7 days of colonoscopy. We used a 20% sample of 2010 Medicare outpatient colonoscopy claims (331,880 colonoscopies performed at 8140 facilities) from patients ≥65 years or older, and developed a patient-level logistic regression model to estimate the risk of unplanned hospital visits (ie, emergency department visits, observation stays, and inpatient admissions) within 7 days of colonoscopy. We then used the patient-level risk model variables and hierarchical logistic regression to estimate facility rates of risk-standardized unplanned hospital visits using data from the Healthcare Cost and Utilization Project (325,811 colonoscopies at 992 facilities), from 4 states containing 100% of colonoscopies per facility. Outpatient colonoscopies were followed by 5412 unplanned hospital visits within 7 days (16.3/1000 colonoscopies). Hemorrhage, abdominal pain, and perforation were the most common causes of unplanned hospital visits. Fifteen variables were independently associated with unplanned hospital visits (c = 0.67). A history of fluid and electrolyte imbalance (odds ratio [OR] = 1.43; 95% confidence interval [CI]: 1.29-1.58), psychiatric disorders (OR = 1.34; 95% CI: 1.22-1.46), and, in the absence of prior arrhythmia, increasing age past 65 years (aged >85 years vs 65-69 years: OR = 1.87; 95% CI: 1.54-2.28) were most strongly associated. The facility risk-standardized unplanned hospital visits calculated using Healthcare Cost and Utilization Project data showed significant variation (median 12.3/1000; 5th-95th percentile, 10.5-14.6/1000). Median risk-standardized unplanned hospital visits were comparable between ambulatory surgery centers and hospital outpatient departments (each was 10.2/1000), and ranged from 16.1/1000 in the Northeast to 17.2/1000 in the Midwest. We calculated a risk-adjusted measure of outpatient colonoscopy quality, which shows important variation in quality among outpatient facilities. This measure can make transparent the extent to which patients require follow-up hospital care, help inform patient choices, and assist in quality-improvement efforts. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  17. Portable inhaled methoxyflurane is feasible and safe for colonoscopy in subjects with morbid obesity and/or obstructive sleep apnea.

    PubMed

    Nguyen, Nam Q; Toscano, Leanne; Lawrence, Matthew; Phan, Vinh-An; Singh, Rajvinder; Bampton, Peter; Fraser, Robert J; Holloway, Richard H; Schoeman, Mark N

    2015-10-01

    Colonoscopy with inhaled methoxyflurane (Penthrox) is well tolerated in unselected subjects and is not associated with respiratory depression. The aim of this prospective study was to compare the feasibility, safety, and post-procedural outcomes of portable methoxyflurane used as an analgesic agent during colonoscopy with those of anesthesia-assisted deep sedation (AADS) in subjects with morbid obesity and/or obstructive sleep apnea (OSA). The outcomes of 140 patients with morbid obesity/OSA who underwent colonoscopy with either Penthrox inhalation (n = 85; 46 men, 39 women; mean age 57.2 ± 1.1 years) or AADS (n = 55; 27 men, 28 women; mean age, 54.9 ± 1.1 years) were prospectively assessed. All Penthrox-assisted colonoscopies were successful, without any requirement for additional intravenous sedation. Compared with AADS, Penthrox was associated with a shorter total procedural time (24 ± 1 vs. 52 ± 1 minutes, P < 0.001), a lower incidence of hypotension (3 /85 vs. 23 /55, P < 0.001), and a lower incidence of respiratory desaturation (0 /85 vs. 14 /55, P < 0.001). The patients in the Penthrox group recovered more rapidly and were discharged much earlier than those in the AADS group (27 ± 2 vs. 97 ± 5 minutes, P < 0.0001). Of those who underwent colonoscopy with Penthrox, 90 % were willing to receive Penthrox again for colonoscopy. More importantly, of the patients who underwent colonoscopy with Penthrox and had had AADS for previous colonoscopy, 82 % (28 /34) preferred to receive Penthrox for future colonoscopies. Penthrox-assisted colonoscopy cost significantly less than colonoscopy with AADS ($ 332 vs. $ 725, P < 0.001), with a cost saving of approximately $ 400 for each additional complication avoided. Compared with AADS, Penthrox is highly feasible and safe in patients with morbid obesity/OSA undergoing colonoscopy and is associated with fewer cardiorespiratory complications. Because of the advantages of this approach in regard to procedural time, recovery time, and cost benefit in comparison with AADS, further evaluation in a randomized trial is warranted.

  18. Predictors for difficult cecal insertion in colonoscopy: The impact of obesity indices

    PubMed Central

    Moon, Soo Yun; Kim, Byung Chang; Sohn, Dae Kyung; Han, Kyung Su; Kim, Bun; Hong, Chang Won; Park, Bum Joon; Ryu, Kum Hei; Nam, Ji Hyung

    2017-01-01

    AIM To identify the factors influencing cecal insertion time (CIT) and to evaluate the effect of obesity indices on CIT. METHODS We retrospectively reviewed the data for participants who received both colonoscopy and abdominal computed tomography (CT) from February 2008 to May 2008 as part of a comprehensive health screening program. Age, gender, obesity indices [body mass index (BMI), waist-to-hip circumference ratio (WHR), waist circumference (WC), visceral adipose tissue (VAT) volume and subcutaneous adipose tissue (SAT) volume on abdominal CT], history of prior abdominal surgery, constipation, experience of the colonoscopist, quality of bowel preparation, diverticulosis and time required to reach the cecum were analyzed. CIT was categorized as longer than 10 min (prolonged CIT) and shorter than or equal to 10 min, and then the factors that required a CIT longer than 10 min were examined. RESULTS A total of 1678 participants were enrolled. The mean age was 50.42 ± 9.931 years and 60.3% were men. The mean BMI, WHR, WC, VAT volume and SAT volume were 23.92 ± 2.964 kg/m2, 0.90 ± 0.076, 86.95 ± 8.030 cm, 905.29 ± 475.220 cm3 and 1707.72 ± 576.550 cm3, respectively. The number of patients who underwent abdominal surgery was 268 (16.0%). Colonoscopy was performed by an attending physician alone in 61.9% of cases and with the involvement of a fellow in 38.1% of cases. The median CIT was 7 min (range 2-56 min, IQR 5-10 min), and mean CIT was 8.58 ± 5.291 min. Being female, BMI, VAT volume and involvement of fellow were significantly associated with a prolonged CIT in univariable analysis. In multivariable analysis, being female (OR = 1.29, P = 0.047), lower BMI (< 23 kg/m2) (OR = 1.62, P = 0.004) or higher BMI (≥ 25 kg/m2) (OR = 1.80, P < 0.001), low VAT volume (< 500 cm3) (OR = 1.50, P = 0.013) and fellow involvement (OR = 1.73, P < 0.001) were significant predictors of prolonged CIT. In subgroup analyses for gender, lower BMI or higher BMI and fellow involvement were predictors for prolonged CIT in both genders. However, low VAT volume was associated with prolonged CIT in only women (OR = 1.54, P = 0.034). CONCLUSION Being female, having a lower or higher BMI than the normal range, a low VAT volume, and fellow involvement were predictors of a longer CIT. PMID:28428714

  19. Educational Colonoscopy Video Enhances Bowel Preparation Quality and Comprehension in an Inner City Population.

    PubMed

    Pillai, Ajish; Menon, Radha; Oustecky, David; Ahmad, Asyia

    2017-07-24

    Quality of bowel preparation and patient knowledge remains a major barrier for completing colorectal cancer screening. Few studies have tested unique ways to impact patient understanding centering on interactive computer programs, pictures, and brochures. Two studies explored instructional videos but focused on patient compliance and anxiety as endpoints. Furthermore, excessive video length and content may limit their impact on a broad patient population. No study so far has studied a video's impact on preparation quality and patient understanding of the colonoscopy procedure. We conducted a single blinded prospective study of inner city patients presenting for a first time screening colonoscopy. During their initial visit patients were randomized to watch an instructional colonoscopy video or a video discussing gastroesophageal reflux disease (GERD). All patients watched a 6 minutes long video with the same spokesperson, completed a demographic questionnaire (Supplemental Digital Content 1, http://links.lww.com/JCG/A352) and were enrolled only if screened within 30 days of their visit. On the day of the colonoscopy, patients completed a 14 question quiz of their knowledge. Blinded endoscopist graded patient preparations based on the Ottawa scale. All authors had access to the study data and reviewed and approved the final manuscript. Among the 104 subjects enrolled in the study, 56 were in the colonoscopy video group, 48 were in GERD video group, and 12 were excluded. Overall, 48% were male and 52% female; 90% of patients had less than a high school education, 76% were African American, and 67% used a 4 L split-dose preparation. There were no differences between either video group with regard to any of the above categories. Comparisons between the 2 groups revealed that the colonoscopy video group had significantly better Ottawa bowel preparation score (4.77 vs. 6.85; P=0.01) than the GERD video group. The colonoscopy video group also had less-inadequate repeat bowel preparations versus the GERD video group (9% vs. 23%; P<0.01). The overall score on the knowledge questionnaire (Supplemental Digital Content 1, http://links.lww.com/JCG/A352) was significantly higher in the colonoscopy video group as compared with the GERD video group (12.77 vs. 11.08; P<0.001. In all patients the overall quiz score positively correlated with preparation quality (odds ratio, 2.31; confidence interval, 1.35-3.94; P<0.001). Our unique population represented an overwhelmingly under-educated (85% had a high school education or less) and minority group (76% African American). They are one of the most at risk of having multiple barriers such as comprehension and reading difficulties resulting in poor preparation examinations and no shows to procedures. Our instructional video proved to be high yield in this population. The patients assigned to watch the colonoscopy video showed a significant increase in "excellent" grade adequate bowel preparation quality by >23% and a significant decrease in "inadequate" bowel preparations by almost 50%. Our study proves that an educational video can improve both comprehension with regard to all aspects of colonoscopy. ClinicalTrials.gov number, NCT02906969.

  20. Three-Dimensional Visualization and Imaging of the Entry Tear and Intimal Flap of Aortic Dissection Using CT Virtual Intravascular Endoscopy

    PubMed Central

    Li, Gang; Ma, Xiangxing; Wang, Qing; Yu, Dexin

    2016-01-01

    Aims Conventional computed tomography (CT) approaches provides limited visualization of the entire endoluminal changes of aortic dissection (AD), which is essential for its treatment. As an important supplement, three-dimensional CT virtual intravascular endoscopy (VIE) can show relevant details. This study aims to determine the value of VIE in displaying the entry tear and intimal flap of AD. Methods and Results Among 127 consecutive symptomatic patients with suspected AD who underwent CT angiography (CTA), 84 subjects were confirmed to have AD and were included in the study. Conventional CT and VIE images were observed and evaluated. From the 92 entry tears revealed via conventional CT, 88 (95.7%) tears appeared on VIE with round (n = 26), slit-shaped (n = 9), or irregular (n = 53) shapes, whereas the intimal flaps were sheetlike (n = 34), tubular (n = 34), wavelike (n = 13), or irregular (n = 7) in shape. The VIE also showed the spatial relationship between the torn flap and adjacent structures. Among 58 entry tears with multiple-line type flap shown on conventional CT, 41 (70.7%) appeared with an irregular shape on VIE, whereas among 30 tears with single-line type flap, 17 (56.7%) appeared as round or slit-shaped on VIE. These results demonstrated a significant difference (P < 0.05). The poor display of tears on VIE was related to the low CT attenuation values in lumen or in neighboring artifacts (P < 0.01). Conclusion CT VIE presents the complete configurations and details of the intimal tears and flaps of AD better than conventional CT approaches. Accordingly, it should be recommended as a necessary assessment tool for endovascular therapy and as part of strategy planning in pre-surgical patients. PMID:27760170

  1. Colonoscopic splenic injuries: incidence and management.

    PubMed

    Kamath, Ashwin S; Iqbal, Corey W; Sarr, Michael G; Cullinane, Daniel C; Zietlow, Scott P; Farley, David R; Sawyer, Mark D

    2009-12-01

    Splenic injuries that occur during colonoscopies are rare. There is no available incidence of this serious complication, and the literature is limited to case reports. Our study looks at single institution experience of splenic injuries during colonoscopy to define the incidence and management of this serious complication. All patients from 1980 through June 2008 sustaining a splenic injury during colonoscopy were reviewed. Four patients (of 296,248 colonoscopies) sustained a splenic injury directly from colonoscopy performed at our institution (incidence 0.001%). Three additional patients were treated at our tertiary referral center after splenic injury from colonoscopy performed elsewhere. The mean age at the time of colonoscopy was 54 years (range 40-70 years). The most common presenting symptom was abdominal pain (n = 4) with a mean decrease in hemoglobin of 6.5 g/dl (range 4.5-8.5 g/dl). Splenic injury was diagnosed by computed tomography in five patients. Six patients received a mean of 5.5 U of packed red blood cells (range 2-14 U). All patients were managed with splenectomy, six patients within 24 h of the index colonoscopy, and one patient presented more than 24 h after initial colonoscopy. There was no evidence of preexisting splenic disease in any of the patients by surgical pathology, and there were no postoperative complications or deaths. The mean duration of stay was 10 days (range 7-15 days). All patients are alive at a median follow up of 22 months (range 1-164 months). Splenic injury occurring during colonoscopy is a rare but serious complication. Patients presented with abdominal pain and a precipitous decrease in hemoglobin and have all required emergent splenectomy.

  2. Colorectal cancer mortality reduction is associated with having at least 1 colonoscopy within the previous 10 years among a population-wide cohort of screening age.

    PubMed

    Stock, David; Paszat, Lawrence F; Rabeneck, Linda

    2016-07-01

    Colonoscopy has been demonstrated to be effective in colorectal cancer (CRC) mortality reduction, although current screening guidelines have yet to be evaluated. We assessed the protective benefit of colonoscopy within the previous 10 years and whether this effect is maintained with age. We used administrative data to compare risk of CRC death (CCD) across colonoscopy utilization among a population-wide cohort comprising individuals aged 60 to 80 years (N = 1,509,423). Baseline and time-dependent colonoscopy exposure models were assessed in the context of competing "other causes of death" (OCDs). Cumulative incidence of CCD and OCD across colonoscopy exposure, over follow-up, was estimated. Relative hazards were computed by age strata (60-69 years, 70-74 years, 75+ years) and proximal and distal cancer subsites. At least 1 colonoscopy during 10 years before baseline was estimated to provide a 51% reduced hazard of CCD (hazard ratio [HR] 0.49; 95% confidence interval [CI], 0.45-0.54) over the following 8 years. When colonoscopy was modeled as a time-dependent covariate, the risk of CCD was further diminished (multivariable-adjusted HR 0.36; 95% CI, 0.33-0.38). Stratified analyses suggested moderately attenuated CCD risk reduction among the oldest age group; however, consideration of OCDs suggest that this is related to competing risks. CCD risk reduction related to colonoscopy was lower for proximal cancers. Colonoscopy within the previous 10 years provides substantial protective benefit for average-risk individuals over 60 years. CCD risk reduction may be maintained well beyond 74 years, a common upper age limit recommended by screening guidelines. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  3. Association Between Socioeconomic Status and Participation in Colonoscopy Screening Program in First Degree Relatives of Colorectal Cancer Patients.

    PubMed

    Chouhdari, Arezoo; Yavari, Parvin; Pourhoseingholi, Mohammad Amin; Sohrabi, Mohammad-Reza

    2016-04-01

    Approximately 15% to 25% of colorectal cancer (CRC) cases have positive family history for disease. Colonoscopy screening test is the best way for prevention and early diagnosis. Studies have found that first degree relatives (FDRs) with low socioeconomic status are less likely to participate in colonoscopy screening program. The aim of this study is to determine the association between socioeconomic status and participation in colonoscopy screening program in FDRs. This descriptive cross-sectional, study has been conducted on 200 FDRs who were consulted for undergoing colonoscopy screening program between 2007 and 2013 in research institute for gastroenterology and liver disease of Shahid Beheshti University of Medical Sciences, Tehran, Iran. They were interviewed via phone by a valid questionnaire about socioeconomic status. For data analysis, chi-square, exact fisher and multiple logistic regression were executed by SPSS 19. The results indicated 58.5% participants underwent colonoscopy screening test at least once to the time of the interview. There was not an association between participation in colonoscopy screening program and socioeconomic status to the time of the interview in binomial analysis. But statistical significance between intention to participate and educational and income level were found. We found, in logistic regression analysis, that high educational level (Diploma and University degree in this survey) was a predictor to participate in colonoscopy screening program in FDRs. According to this survey low socioeconomic status is an important factor to hinder participation of FDRs in colonoscopy screening program. Therefore, planned interventions for elevation knowledge and attitude in FDRs with low educational level are necessary. Also, reducing colonoscopy test costs should be a major priority for policy makers.

  4. One-day bowel preparation with polyethylene glycol 3350: an effective regimen for colonoscopy in children.

    PubMed

    Adamiak, Tonya; Altaf, Muhammad; Jensen, Michael K; Sultan, Mutaz; Ramprasad, Jonathan; Ciecierega, Thomas; Sherry, Karen; Miranda, Adrian

    2010-03-01

    Polyethylene glycol (PEG) 3350 is commonly used and has been proven safe and effective for the treatment of chronic constipation and as a 4-day bowel preparation in children. A 1-day PEG 3350 bowel preparation regimen has been recently developed for adults; however, data regarding its use in children are lacking. To evaluate the safety and effectiveness of a 1-day PEG 3350 regimen for bowel preparation in children before colonoscopy. Retrospective review. Tertiary-care center. This study involved all children prescribed a 1-day PEG 3350 bowel preparation regimen before colonoscopy at our center in 2008. We reviewed medical records of patients (< or = 18 years of age) who underwent colonoscopy during 2008 and received the 1-day bowel preparation regimen. Adequate preparation for colonoscopy, success of colonoscopy, and factors associated with inadequate bowel preparation. Inclusion criteria were met by 272 patients. The median age of the children receiving the 1-day PEG 3350 preparation regimen was 13.7 years (range 1.08-17.92 years). Fifty-two percent were male; 48% were female. The most common indications for colonoscopy included abdominal pain (65%), bloody stools (29%), diarrhea (21%), and weight loss (18%). The 1-day bowel preparation regimen was effective in 253 patients (93%). The indication for colonoscopy, the age of the child, or a history of constipation did not significantly alter the success rate of colonoscopy. A retrospective study at one tertiary-care center. The 1-day PEG 3350 bowel preparation regimen is safe and effective and should be considered for use as preparation for colonoscopy in children. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  5. New tools for sculpting cranial implants in a shared haptic augmented reality environment.

    PubMed

    Ai, Zhuming; Evenhouse, Ray; Leigh, Jason; Charbel, Fady; Rasmussen, Mary

    2006-01-01

    New volumetric tools were developed for the design and fabrication of high quality cranial implants from patient CT data. These virtual tools replace time consuming physical sculpting, mold making and casting steps. The implant is designed by medical professionals in tele-immersive collaboration. Virtual clay is added in the virtual defect area on the CT data using the adding tool. With force feedback the modeler can feel the edge of the defect and fill only the space where no bone is present. A carving tool and a smoothing tool are then used to sculpt and refine the implant. To make a physical evaluation, the skull with simulated defect and the implant are fabricated via stereolithography to allow neurosurgeons to evaluate the quality of the implant. Initial tests demonstrate a very high quality fit. These new haptic volumetric sculpting tools are a critical component of a comprehensive tele-immersive system.

  6. Feasibility of dual-energy computed tomography in radiation therapy planning

    NASA Astrophysics Data System (ADS)

    Sheen, Heesoon; Shin, Han-Back; Cho, Sungkoo; Cho, Junsang; Han, Youngyih

    2017-12-01

    In this study, the noise level, effective atomic number ( Z eff), accuracy of the computed tomography (CT) number, and the CT number to the relative electron density EDconversion curve were estimated for virtual monochromatic energy and polychromatic energy. These values were compared to the theoretically predicted values to investigate the feasibility of the use of dual-energy CT in routine radiation therapy planning. The accuracies of the parameters were within the range of acceptability. These results can serve as a stepping stone toward the routine use of dual-energy CT in radiotherapy planning.

  7. Potential testing of reprocessing procedures by real-time polymerase chain reaction: A multicenter study of colonoscopy devices.

    PubMed

    Valeriani, Federica; Agodi, Antonella; Casini, Beatrice; Cristina, Maria Luisa; D'Errico, Marcello Mario; Gianfranceschi, Gianluca; Liguori, Giorgio; Liguori, Renato; Mucci, Nicolina; Mura, Ida; Pasquarella, Cesira; Piana, Andrea; Sotgiu, Giovanni; Privitera, Gaetano; Protano, Carmela; Quattrocchi, Annalisa; Ripabelli, Giancarlo; Rossini, Angelo; Spagnolo, Anna Maria; Tamburro, Manuela; Tardivo, Stefano; Veronesi, Licia; Vitali, Matteo; Romano Spica, Vincenzo

    2018-02-01

    Reprocessing of endoscopes is key to preventing cross-infection after colonoscopy. Culture-based methods are recommended for monitoring, but alternative and rapid approaches are needed to improve surveillance and reduce turnover times. A molecular strategy based on detection of residual traces from gut microbiota was developed and tested using a multicenter survey. A simplified sampling and DNA extraction protocol using nylon-tipped flocked swabs was optimized. A multiplex real-time polymerase chain reaction (PCR) test was developed that targeted 6 bacteria genes that were amplified in 3 mixes. The method was validated by interlaboratory tests involving 5 reference laboratories. Colonoscopy devices (n = 111) were sampled in 10 Italian hospitals. Culture-based microbiology and metagenomic tests were performed to verify PCR data. The sampling method was easily applied in all 10 endoscopy units and the optimized DNA extraction and amplification protocol was successfully performed by all of the involved laboratories. This PCR-based method allowed identification of both contaminated (n = 59) and fully reprocessed endoscopes (n = 52) with high sensibility (98%) and specificity (98%), within 3-4 hours, in contrast to the 24-72 hours needed for a classic microbiology test. Results were confirmed by next-generation sequencing and classic microbiology. A novel approach for monitoring reprocessing of colonoscopy devices was developed and successfully applied in a multicenter survey. The general principle of tracing biological fluids through microflora DNA amplification was successfully applied and may represent a promising approach for hospital hygiene. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  8. Scottish Bowel Screening Programme Colonoscopy Quality - scope for improvement?

    PubMed

    Quyn, A J; Fraser, C G; Stanners, G; Carey, F A; Rees, C J; Moores, B; Steele, R J

    2018-06-04

    The delivery of the Scottish Bowel Screening Programme (SBoSP) is rooted in the provision of a high quality, effective and participant-centred service. Safe and effective colonoscopy forms an integral part of the process. Additional accreditation as part of a multi-faceted programme for participating colonoscopists, as in England, does not exist in Scotland. This study aimed to describe the quality of colonoscopy in the SBoSP and compare this to the English national screening standards. Data were collected from the SBoSP between 2007 and 2014. End-points for analysis were caecal intubation, cancer, polyp and adenoma detection, and complications. Overall results were compared with 2012 published English national standards for screening and outcomes from 2006-2009. During the study period 53,332 participants attended for colonoscopy. Colonoscopy completion rate was 95.6% overall. The mean cancer detection rate (CDR) was 7.1%, the polyp detection rate (PDR) 45.7% and the adenoma detection rate (ADR) was 35.5%.The overall complication rate was 0.47%. Colonoscopy quality in the SBoSP has exceeded the standard set for screening colonoscopy in England, despite not adopting a multi-faceted programme for screening colonoscopy. However, the overall ADR in Scotland was 9.1% lower than that in England which has implications for colonoscopy quality and may have an impact on the cancer prevention rates, a key aim of the SBoSP. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Factors Associated with Anxiety About Colonoscopy: The Preparation, the Procedure, and the Anticipated Findings.

    PubMed

    Shafer, L A; Walker, J R; Waldman, C; Yang, C; Michaud, V; Bernstein, C N; Hathout, L; Park, J; Sisler, J; Restall, G; Wittmeier, K; Singh, H

    2018-03-01

    Previous research has assessed anxiety around colonoscopy procedures, but has not considered anxiety related to different aspects related to the colonoscopy process. Before colonoscopy, we assessed anxiety about: bowel preparation, the procedure, and the anticipated results. We evaluated associations between patient characteristics and anxiety in each area. An anonymous survey was distributed to patients immediately prior to their outpatient colonoscopy in six hospitals and two ambulatory care centers in Winnipeg, Canada. Anxiety was assessed using a visual analog scale. For each aspect, logistic regression models were used to explore associations between patient characteristics and high anxiety. A total of 1316 respondents completed the questions about anxiety (52% female, median age 56 years). Anxiety scores > 70 (high anxiety) were reported by 18% about bowel preparation, 29% about the procedure, and 28% about the procedure results. High anxiety about bowel preparation was associated with female sex, perceived unclear instructions, unfinished laxative, and no previous colonoscopies. High anxiety about the procedure was associated with female sex, no previous colonoscopies, and confusing instructions. High anxiety about the results was associated with symptoms as an indication for colonoscopy and instructions perceived as confusing. Fewer people had high anxiety about preparation than about the procedure and findings of the procedure. There are unique predictors of anxiety about each colonoscopy aspect. Understanding the nuanced differences in aspects of anxiety may help to design strategies to reduce anxiety, leading to improved acceptance of the procedure, compliance with preparation instructions, and less discomfort with the procedure.

  10. Endoscopic bronchial occlusion for postoperative persistent bronchopleural fistula with computed tomography fluoroscopy guidance and virtual bronchoscopic navigation

    PubMed Central

    Yanagiya, Masahiro; Matsumoto, Jun; Nagano, Masaaki; Kusakabe, Masashi; Matsumoto, Yoko; Furukawa, Ryutaro; Ohara, Sayaka; Usui, Kazuhiro

    2018-01-01

    Abstract Rationale: The development of postoperative bronchopleural fistula (BPF) remains a challenge in thoracic surgery. We herein report a case of BPF successfully treated with endoscopic bronchial occlusion under computed tomography (CT) fluoroscopy and virtual bronchoscopic navigation (VBN). Patient concerns: A 63-year-old man underwent right upper lobectomy with concomitant S6a subsegmentectomy for lung adenocarcinoma. On postoperative day 24, he complained of shaking chills with high fever. Diagnoses: BPF with subsequent pneumonia and empyema. Interventions: Despite aggressive surgical interventions for the BPF, air leakage persisted postoperatively. On days 26 and 34 after the final operation, endobronchial occlusions were performed under CT fluoroscopy and VBN. Outcomes: The air leaks greatly decreased and the patient was discharged. Lessons: CT fluoroscopy and VBN can be useful techniques for endobronchial occlusion in the treatment of BPF. PMID:29443771

  11. An Investigation of the Incorporation of Virtual Microscopy in the Cytotechnology Educational Curriculum

    ERIC Educational Resources Information Center

    Mukherjee, Maheswari S.

    2012-01-01

    Traditionally, cytotechnology (CT) students have been trained by using light microscopy (LM) and glass slides. However, this method of training has some drawbacks. Several other educational programs with similar issues have incorporated virtual microscopy (VM) in their curricula. In VM, the specimens on glass slides are converted into virtual…

  12. Can Technology Improve the Quality of Colonoscopy?

    PubMed

    Thirumurthi, Selvi; Ross, William A; Raju, Gottumukkala S

    2016-07-01

    In order for screening colonoscopy to be an effective tool in reducing colon cancer incidence, exams must be performed in a high-quality manner. Quality metrics have been presented by gastroenterology societies and now include higher adenoma detection rate targets than in the past. In many cases, the quality of colonoscopy can often be improved with simple low-cost interventions such as improved procedure technique, implementing split-dose bowel prep, and monitoring individuals' performances. Emerging technology has expanded our field of view and image quality during colonoscopy. We will critically review several technological advances in the context of quality metrics and discuss if technology can really improve the quality of colonoscopy.

  13. Optimizing bowel preparation for colonoscopy: a guide to enhance quality of visualization

    PubMed Central

    Bechtold, Matthew L.; Mir, Fazia; Puli, Srinivas R.; Nguyen, Douglas L.

    2016-01-01

    Colonoscopy is an important screening and therapeutic modality for colorectal cancer. Unlike other screening tests, colonoscopy is dependent on pre-procedure bowel preparation. If the bowel preparation is poor, significant pathology may be missed. Many factors are known to improve bowel preparation. This review will highlight those factors that may optimize the bowel preparation, including choice of bowel preparation, grading or scoring of the bowel preparation, special factors that influence preparation, and diet prior to colonoscopy that affects bowel preparation. The aim of the review is to offer suggestions and guide endoscopists on how to optimize the bowel preparation for the patients undergoing colonoscopy. PMID:27065725

  14. AFRICAN-AMERICANS’ AND LATINOS’ PERCEPTIONS OF USING HYPNOSIS TO ALLEVIATE DISTRESS BEFORE A COLONOSCOPY

    PubMed Central

    Miller, Sarah J.; Schnur, Julie B.; Montgomery, Guy H.; Jandorf, Lina

    2013-01-01

    Although colorectal cancer (CRC) screenings can effectively detect and prevent cancer, a large portion of African-Americans and Latinos do not undergo regular colonoscopy screening. Research suggests that anticipatory distress can significantly hinder minorities’ adherence to colonoscopy recommendations. There is significant promise that hypnosis may effectively reduce such distress. The current study examined African-Americans’ and Latinos’ (n = 213) perceptions of using hypnosis prior to a colonoscopy. Overall, 69.9% of the sample expressed favourable perceptions of using pre-colonoscopy hypnosis, although there was notable variability. The results from this study can guide clinical decision making and inform future research efforts. PMID:26566440

  15. Prior image constrained image reconstruction in emerging computed tomography applications

    NASA Astrophysics Data System (ADS)

    Brunner, Stephen T.

    Advances have been made in computed tomography (CT), especially in the past five years, by incorporating prior images into the image reconstruction process. In this dissertation, we investigate prior image constrained image reconstruction in three emerging CT applications: dual-energy CT, multi-energy photon-counting CT, and cone-beam CT in image-guided radiation therapy. First, we investigate the application of Prior Image Constrained Compressed Sensing (PICCS) in dual-energy CT, which has been called "one of the hottest research areas in CT." Phantom and animal studies are conducted using a state-of-the-art 64-slice GE Discovery 750 HD CT scanner to investigate the extent to which PICCS can enable radiation dose reduction in material density and virtual monochromatic imaging. Second, we extend the application of PICCS from dual-energy CT to multi-energy photon-counting CT, which has been called "one of the 12 topics in CT to be critical in the next decade." Numerical simulations are conducted to generate multiple energy bin images for a photon-counting CT acquisition and to investigate the extent to which PICCS can enable radiation dose efficiency improvement. Third, we investigate the performance of a newly proposed prior image constrained scatter correction technique to correct scatter-induced shading artifacts in cone-beam CT, which, when used in image-guided radiation therapy procedures, can assist in patient localization, and potentially, dose verification and adaptive radiation therapy. Phantom studies are conducted using a Varian 2100 EX system with an on-board imager to investigate the extent to which the prior image constrained scatter correction technique can mitigate scatter-induced shading artifacts in cone-beam CT. Results show that these prior image constrained image reconstruction techniques can reduce radiation dose in dual-energy CT by 50% in phantom and animal studies in material density and virtual monochromatic imaging, can lead to radiation dose efficiency improvement in multi-energy photon-counting CT, and can mitigate scatter-induced shading artifacts in cone-beam CT in full-fan and half-fan modes.

  16. Wide coverage by volume CT: benefits for cardiac imaging

    NASA Astrophysics Data System (ADS)

    Sablayrolles, Jean-Louis; Cesmeli, Erdogan; Mintandjian, Laura; Adda, Olivier; Dessalles-Martin, Diane

    2005-04-01

    With the development of new technologies, computed tomography (CT) is becoming a strong candidate for non-invasive imaging based tool for cardiac disease assessment. One of the challenges of cardiac CT is that a typical scan involves a breath hold period consisting of several heartbeats, about 20 sec with scanners having a longitudinal coverage of 2 cm, and causing the image quality (IQ) to be negatively impacted since beat to beat variation is high likely to occur without any medication, e.g. beta blockers. Because of this and the preference for shorter breath hold durations, a CT scanner with a wide coverage without the compromise in the spatial and temporal resolution of great clinical value. In this study, we aimed at determining the optimum scan duration and the delay relative to beginning of breath hold, to achieve high IQ. We acquired EKG data from 91 consecutive patients (77 M, 14 F; Age: 57 +/- 14) undergoing cardiac CT exams with contrast, performed on LightSpeed 16 and LightSpeed Pro16. As an IQ metric, we adopted the standard deviation of "beat-to-beat variation" (stdBBV) within a virtual scan period. Two radiologists evaluated images by assigning a score of 1 (worst) to 4 best). We validated stdBBV with the radiologist scores, which resulted in a population distribution of 9.5, 9.5, 31, and 50% for the score groups 1, 2, 3, and 4, respectively. Based on the scores, we defined a threshold for stdBBV and identified an optimum combination of virtual scan period and a delay. With the assumption that the relationship between the stdBBV and diagnosable scan IQ holds, our analysis suggested that the success rate can be improved to 100% with scan durations equal or less than 5 sec with a delay of 1 - 2 sec. We confirmed the suggested conclusion with LightSpeed VCT (GE Healthcare Technologies, Waukesha, WI), which has a wide longitudinal coverage, fine isotropic spatial resolution, and high temporal resolution, e.g. 40 mm coverage per rotation of 0.35 sec. Under the light of this study, LightSpeed VCT lends itself to be a clinically tested unique platform to achieve routine cardiac imaging.

  17. Colonoscopy: practice variation among 69 hospital-based endoscopists.

    PubMed

    Cotton, Peter B; Connor, Patrick; McGee, Daniel; Jowell, Paul; Nickl, Nick; Schutz, Steve; Leung, Joseph; Lee, John; Libby, Eric

    2003-03-01

    The medical profession, payers, and patients are interested increasingly in the quality of endoscopic procedures, including colonoscopy. The American Society for Gastrointestinal Endoscopy has recommended "report cards" by which endoscopists may keep track of certain key elements of their practice including indications, findings, duration, technical end points, complications, and patient satisfaction. The GI-Trac endoscopy reporting database includes many of the data points recommended by ASGE for report cards. Seven hospital centers in North America have been collecting data prospectively for varying periods since 1994. These data were aggregated and analyzed by individual endoscopist. A total of 69 endoscopists performed 17,868 colonoscopies. Twelve percent of the endoscopists reported that more than 20% of procedures they performed were completely normal. The average time taken by 27% of endoscopists was more than 40 minutes (without trainees involved), and only 55% achieved a cecal intubation rate of over 90%; for 9% the rate was less than 80%. Complication rates were too low for individual comparisons. These data provide an idea of colonoscopy performance by individual endoscopists in mainly academic centers. Incorporating all recommended data elements in future reporting databases will contribute to meaningful bench marking and to quality improvement efforts.

  18. Virtual tissue alignment and cutting plane definition – a new method to obtain optimal longitudinal histological sections

    PubMed Central

    Danz, J C; Habegger, M; Bosshardt, D D; Katsaros, C; Stavropoulos, A

    2014-01-01

    Histomorphometric evaluation of the buccal aspects of periodontal tissues in rodents requires reproducible alignment of maxillae and highly precise sections containing central sections of buccal roots; this is a cumbersome and technically sensitive process due to the small specimen size. The aim of the present report is to describe and analyze a method to transfer virtual sections of micro-computer tomographic (CT)-generated image stacks to the microtome for undecalcified histological processing and to describe the anatomy of the periodontium in rat molars. A total of 84 undecalcified sections of all buccal roots of seven untreated rats was analyzed. The accuracy of section coordinate transfer from virtual micro-CT slice to the histological slice, right–left side differences and the measurement error for linear and angular measurements on micro-CT and on histological micrographs were calculated using the Bland–Altman method, interclass correlation coefficient and the method of moments estimator. Also, manual alignment of the micro-CT-scanned rat maxilla was compared with multiplanar computer-reconstructed alignment. The supra alveolar rat anatomy is rather similar to human anatomy, whereas the alveolar bone is of compact type and the keratinized gingival epithelium bends apical to join the junctional epithelium. The high methodological standardization presented herein ensures retrieval of histological slices with excellent display of anatomical microstructures, in a reproducible manner, minimizes random errors, and thereby may contribute to the reduction of number of animals needed. PMID:24266502

  19. Physician-patient and patient-family communication after colonoscopy.

    PubMed

    Jiménez, Jessica A; Jung, Barbara; Madlensky, Lisa

    2012-09-01

    A personal or family history of colorectal adenomas increases the risk of colorectal cancer (CRC). We aimed to compare physicians' communication with polyp patients vs. non-polyp patients, assess whether polyps or CRC family history were associated with physician-patient communication, and describe patients' disclosure of colonoscopy and polyp diagnosis to their relatives. Four hundred nine patients completed an online survey regarding physician-patient communication of colonoscopy results, perceived personal and familial risk of polyps and CRC, and disclosure of colonoscopy results to relatives. Six percent of participants reported that their physicians discussed familial risks. Polyp diagnosis and family history predicted physician-patient discussions about familial CRC risks. Polyp diagnosis predicted physician-patient discussions of future surveillance. Twenty-two percent of patients told none of their relatives that they had a colonoscopy. Family history, gender, and education were associated with patient-family communication. There is room for improvement in physician-patient and patient-family communication following colonoscopy.

  20. SU-G-IeP4-07: Feasibility of Low Dose 18FDG PET in Pediatric Oncology Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Binzel, K; Hall, NC

    Purpose: To evaluate and demonstrate the feasibility of low dose FDG PET in pediatric oncology patients using virtual dose reduction as well as true patients PET/CT scans. Methods: Wholebody 18F-FDG PET/CT of 39 clinical pediatric patients (0.16±0.06MBq/kg) were scanned on a Gemini TF 64 system at 75±5 min post FDG injection using 3min/bed. Based on the 180s/bed listmode PET data, subsets of total counts in 120s, 90s, 60s, 30s and 15s per bed position were extracted for PET reconstruction to simulate lower dose PET at 2/3th, 1/2th, 1/3th, 1/6th and 1/12th dose levels. PET/CT scans of Jaszczak PET phantom withmore » 6 hot hollow spheres varying with sizes and contrast ratios were performed (real PET versus simulated PET) to validate the methodology of virtual dose PET simulation. Region of interests (ROIs) were placed on lesions and normal anatomical tissues with quantitative and qualitative assessment performed. Significant lower FDG dose PET/CT of 5 research adolescents were scanned to validate the proposal and low dose PET feasibility. Results: Although all lesions are visible on the 1/12th dose PET, overall PET image quality appears to be influenced in a multi-factorial way. 30%–60% dose reduction from current standard of care FDG PET is recommended to maintain equivalent quality and PET quantification. An optimized BMI-based FDG administration is recommended (from 1.1±0.5 mCi for BMI < 18.5 to 4.8±1.5 mCi for BMI > 30). A linear lowest “Dose-BMI” relationship is given. SUVs from 1/12th to full dose PETs were identified as consistent (R2 = 1.08, 0.99, 1.01, 1.00 and 0.98). No significant variances of count density, SUV and SNR were found across certain dose ranges (p<0.01). Conclusion: Pediatric PET/CT can be performed using current time-of-flight systems at substantially lower PET doses (30–60%) than the standard of care PET/CT without compromising qualitative and quantitative image quality in clinical.« less

  1. Application of fluence field modulation to proton computed tomography for proton therapy imaging.

    PubMed

    Dedes, G; De Angelis, L; Rit, S; Hansen, D; Belka, C; Bashkirov, V; Johnson, R P; Coutrakon, G; Schubert, K E; Schulte, R W; Parodi, K; Landry, G

    2017-07-12

    This simulation study presents the application of fluence field modulated computed tomography, initially developed for x-ray CT, to proton computed tomography (pCT). By using pencil beam (PB) scanning, fluence modulated pCT (FMpCT) may achieve variable image quality in a pCT image and imaging dose reduction. Three virtual phantoms, a uniform cylinder and two patients, were studied using Monte Carlo simulations of an ideal list-mode pCT scanner. Regions of interest (ROI) were selected for high image quality and only PBs intercepting them preserved full fluence (FF). Image quality was investigated in terms of accuracy (mean) and noise (standard deviation) of the reconstructed proton relative stopping power compared to reference values. Dose calculation accuracy on FMpCT images was evaluated in terms of dose volume histograms (DVH), range difference (RD) for beam-eye-view (BEV) dose profiles and gamma evaluation. Pseudo FMpCT scans were created from broad beam experimental data acquired with a list-mode pCT prototype. FMpCT noise in ROIs was equivalent to FF images and accuracy better than  -1.3%(-0.7%) by using 1% of FF for the cylinder (patients). Integral imaging dose reduction of 37% and 56% was achieved for the two patients for that level of modulation. Corresponding DVHs from proton dose calculation on FMpCT images agreed to those from reference images and 96% of BEV profiles had RD below 2 mm, compared to only 1% for uniform 1% of FF. Gamma pass rates (2%, 2 mm) were 98% for FMpCT while for uniform 1% of FF they were as low as 59%. Applying FMpCT to preliminary experimental data showed that low noise levels and accuracy could be preserved in a ROI, down to 30% modulation. We have shown, using both virtual and experimental pCT scans, that FMpCT is potentially feasible and may allow a means of imaging dose reduction for a pCT scanner operating in PB scanning mode. This may be of particular importance to proton therapy given the low integral dose found outside the target.

  2. An evaluation on CT image acquisition method for medical VR applications

    NASA Astrophysics Data System (ADS)

    Jang, Seong-wook; Ko, Junho; Yoo, Yon-sik; Kim, Yoonsang

    2017-02-01

    Recent medical virtual reality (VR) applications to minimize re-operations are being studied for improvements in surgical efficiency and reduction of operation error. The CT image acquisition method considering three-dimensional (3D) modeling for medical VR applications is important, because the realistic model is required for the actual human organ. However, the research for medical VR applications has focused on 3D modeling techniques and utilized 3D models. In addition, research on a CT image acquisition method considering 3D modeling has never been reported. The conventional CT image acquisition method involves scanning a limited area of the lesion for the diagnosis of doctors once or twice. However, the medical VR application is required to acquire the CT image considering patients' various postures and a wider area than the lesion. A wider area than the lesion is required because of the necessary process of comparing bilateral sides for dyskinesia diagnosis of the shoulder, pelvis, and leg. Moreover, patients' various postures are required due to the different effects on the musculoskeletal system. Therefore, in this paper, we perform a comparative experiment on the acquired CT images considering image area (unilateral/bilateral) and patients' postures (neutral/abducted). CT images are acquired from 10 patients for the experiments, and the acquired CT images are evaluated based on the length per pixel and the morphological deviation. Finally, by comparing the experiment results, we evaluate the CT image acquisition method for medical VR applications.

  3. Telephone reminder call in addition to mailing notification improved the acceptance rate of colonoscopy in patients with a positive fecal immunochemical test.

    PubMed

    Cha, Jae Myung; Lee, Joung Il; Joo, Kwang Ro; Shin, Hyun Phil; Park, Jae Jun

    2011-11-01

    Colorectal cancer (CRC) screening with a fecal immunochemical test (FIT) reduces CRC mortality; however, the acceptance rate of a colonoscopy in patients with a positive FIT was not high. The aim of this study was therefore to determine whether a telephone reminder call could increase the acceptance rate of colonoscopy in patients with a positive FIT. We performed FITs for asymptomatic participants aged 50 years or older. For patients with a positive FIT, a colonoscopy was recommended via mailing notification only (control group) or via a telephone reminder call after mailing notification (intervention group). The calls informed patients about the significance of a positive FIT and encouraged a colonoscopy following positive FITs. The FIT results were positive in 90 of 8,318 patients who received FITs. Fifty patients were advised to receive colonoscopy via mailing notification only, and 40 patients were advised via both a telephone reminder call and a mailing notification. The acceptance rate of colonoscopy was significantly higher in the intervention group than in the control group (p = 0.038). The lesion-detection rate for an advanced neoplasia was also significantly higher in the intervention group than in the control group (p = 0.046). According to multivariate logistic regression analysis, a telephone reminder was a significant determinant of colonoscopy acceptance in patients with a positive FIT (OR 4.33; 95% CI, 1.19-15.75; p = 0.026). Telephone reminder calls in addition to mailing notification improved the acceptance rate of colonoscopy in patients with a positive FIT.

  4. A centrally generated primary care physician audit report does not improve colonoscopy uptake after a positive result on a fecal occult blood test in Ontario's ColonCancerCheck program.

    PubMed

    Stock, D; Rabeneck, L; Baxter, N N; Paszat, L F; Sutradhar, R; Yun, L; Tinmouth, J

    2017-02-01

    Timely follow-up of fecal occult blood screening with colonoscopy is essential for achieving colorectal cancer mortality reduction. In the present study, we evaluated the effectiveness of centrally generated, physician-targeted audit and feedback to improve colonoscopy uptake after a positive fecal occult blood test (fobt) result within Ontario's population-wide ColonCancerCheck Program. This prospective cohort study used data sets from Ontario's ColonCancerCheck Program (2008-2011) that were linked to provincial administrative health databases. Cox proportional hazards regression was used to estimate the effect of centralized, physician-targeted audit and feedback on colonoscopy uptake in an Ontario-wide fobt-positive cohort. A mailed physician audit and feedback report identifying individuals outstanding for colonoscopy for 3 or more months after a positive fobt result did not increase the likelihood of colonoscopy uptake (hazard ratio: 0.95; 95% confidence interval: 0.79 to 1.13). Duration of positive fobt status was strongly inversely associated with the hazard of follow-up colonoscopy ( p for linear trend: <0.001). In a large population-wide setting, centralized tracking in the form of physician-targeted mailed audit and feedback reports does not improve colonoscopy uptake for screening participants with a positive fobt result outstanding for 3 or more months. Mailed physician-targeted screening audit and feedback reports alone are unlikely to improve compliance with follow-up colonoscopy in Ontario. Other interventions such as physician audits or automatic referrals, demonstrated to be effective in other jurisdictions, might be warranted.

  5. Randomized controlled trial of probiotics after colonoscopy.

    PubMed

    D'Souza, Basil; Slack, Timothy; Wong, Shing W; Lam, Francis; Muhlmann, Mark; Koestenbauer, Jakob; Dark, Jonathan; Newstead, Graham

    2017-09-01

    Up to 20% of patients have ongoing abdominal symptoms at day 2 and beyond following colonoscopy. It was hypothesized that some of these symptoms are related to alterations in gut microbiota secondary to bowel preparation and would improve with probiotics compared with placebo. Patients were given either a probiotic or placebo capsule in the days following colonoscopy. Colonoscopy was performed with air insufflation. The probiotic capsule contained the strains Lactobacillus acidophilus NCFM and Bifidobacterium lactis Bi-07. Patients recorded their symptoms at 1 h, 1, 2, 4, 7 and 14 days post colonoscopy and returned results once their symptoms had resolved. The primary outcomes used were the length of days to resolution of bloating, abdominal pain and altered bowel function post colonoscopy. A total of 320 patients were randomized. After loss to follow-up and withdrawal, 133 patients were analysed in the probiotic group and 126 in the placebo group. Patients having probiotic had a lower number of pain days following colonoscopy, 1.99 versus 2.78 days (P < 0.033). There was no significant difference in bloating or return to normal bowel habit days (P = 0.139 and 0.265 respectively). Subgroup analysis revealed that patients with pre-existing abdominal pain benefited from probiotics in number of pain days, 2.16 versus 4.08 (P = 0.0498). Our study has shown a significant reduction in the duration of pain days post colonoscopy in patients taking probiotic compared with placebo. No significant effect was seen in terms of return to normal bowel function or bloating post colonoscopy. © 2015 Royal Australasian College of Surgeons.

  6. A novel balloon colonoscope detects significantly more simulated polyps than a standard colonoscope in a colon model.

    PubMed

    Hasan, Nazia; Gross, Seth A; Gralnek, Ian M; Pochapin, Mark; Kiesslich, Ralf; Halpern, Zamir

    2014-12-01

    Although standard colonoscopy is considered the optimal test to detect adenomas, it can have a significant adenoma miss rate. A major contributing factor to high miss rates is the inability to visualize adenomas behind haustral folds and at anatomic flexures. To compare the diagnostic yield of balloon-assisted colonoscopy versus standard colonoscopy in the detection of simulated polyps in a colon model. Prospective, cohort study. International gastroenterology meeting. A colon model composed of elastic material, which mimics the flexible structure of haustral folds, allowing for dynamic responses to balloon inflation, with embedded simulated colon polyps (n = 12 silicone "polyps"). Fifty gastroenterologists were recruited to identify simulated colon polyps in a colon model, first using standard colonoscopy immediately followed by balloon-assisted colonoscopy. Detection of simulated polyps. The median polyp detection rate for all simulated polyps was significantly higher with balloon-assisted as compared with standard colonoscopy (91.7% vs 45.8%, respectively; P < .0001). The significantly higher simulated polyp detection rate with balloon-assisted versus standard colonoscopy was notable both for non-obscured polyps (100.0% vs 75.0%; P < .0001) and obscured polyps (88.0% vs 25.0%; P < .0001). Non-randomized design, use of a colon model, and simulated colon polyps. As compared with standard colonoscopy, balloon-assisted colonoscopy detected significantly more obscured and non-obscured simulated polyps in a colon model. Clinical studies in human participants are being pursued to further evaluate this new colonoscopic technology. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  7. Back-to-back colon capsule endoscopy and optical colonoscopy in colorectal cancer screening individuals.

    PubMed

    Kobaek-Larsen, M; Kroijer, R; Dyrvig, A-K; Buijs, M M; Steele, R J C; Qvist, N; Baatrup, G

    2018-06-01

    The aim was to determine the polyp detection rate and per-patient sensitivity for polyps > 9 mm of colon capsule endoscopy (CCE) compared with colonoscopy as well as the diagnostic accuracy of CCE. Individuals who had a positive immunochemical faecal occult blood test during screening had investigator blinded CCE and colonoscopy. Participants underwent repeat endoscopy if significant lesions detected by CCE were considered to have been missed by colonoscopy. There were 253 participants. The polyp detection rate was significantly higher in CCE compared with colonoscopy (P = 0.02). The per-patient sensitivity for > 9 mm polyps for CCE and colonoscopy was 87% (95% CI: 83-91%) and 88% (95% CI: 84-92%) respectively. In participants with complete CCE and colonoscopy examinations (N = 126), per-patient sensitivity of > 9 mm polyps in CCE (97%; 95% CI: 94-100%) was superior to colonoscopy (89%; 95% CI: 84-94%). A complete capsule endoscopy examination (N = 134) could detect patients with intermediate or greater risk (according to the European guidelines) with an accuracy, sensitivity, specificity and positivity rate of 79%, 93%, 69% and 58% respectively, using a cut-off of at least one polyp > 10 mm or more than two polyps. CCE is superior to colonoscopy in polyp detection rate and per-patient sensitivity to > 9 mm polyps, but only in complete CCE examinations. The rate of incomplete CCE examinations must be improved. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  8. Pros and cons of colonoscopy in management of acute lower gastrointestinal bleeding

    PubMed Central

    Lhewa, Dekey Y; Strate, Lisa L

    2012-01-01

    Acute lower gastrointestinal bleeding (LGIB) is a frequent gastrointestinal cause of hospitalization, particularly in the elderly, and its incidence appears to be on the rise. Endoscopic and radiographic measures are available for the evaluation and treatment of LGIB including flexible sigmoidoscopy, colonoscopy, angiography, radionuclide scintigraphy and multi-detector row computed tomography. Although no modality has emerged as the gold standard in the management of LGIB, colonoscopy is the current preferred initial test for the majority of the patients presenting with hematochezia felt to be from a colon source. Colonoscopy has the ability to diagnose all sources of bleeding from the colon and, unlike the radiologic modalities, does not require active bleeding at the time of the examination. In addition, therapeutic interventions such as cautery and endoclips can be applied to achieve hemostasis and prevent recurrent bleeding. Studies suggest that colonoscopy, particularly when performed early in the hospitalization, can decrease hospital length of stay, rebleeding and the need for surgery. However, results from available small trials are conflicting and larger, multicenter studies are needed. Compared to other management options, colonoscopy is a safe procedure with complications reported in less than 2% of patients, including those undergoing urgent examinations. The requirement of bowel preparation (typically 4 or more liters of polyethylene glycol), the logistical complexity of coordinating after-hours colonoscopy, and the low prevalence of stigmata of hemorrhage complicate the use of colonoscopy for LGIB, particularly in urgent situations. This review discusses the above advantages and disadvantages of colonoscopy in the management of acute lower gastrointestinal bleeding in further detail. PMID:22468081

  9. Optimal preparation-to-colonoscopy interval in split-dose PEG bowel preparation determines satisfactory bowel preparation quality: an observational prospective study.

    PubMed

    Seo, Eun Hee; Kim, Tae Oh; Park, Min Jae; Joo, Hee Rin; Heo, Nae Yun; Park, Jongha; Park, Seung Ha; Yang, Sung Yeon; Moon, Young Soo

    2012-03-01

    Several factors influence bowel preparation quality. Recent studies have indicated that the time interval between bowel preparation and the start of colonoscopy is also important in determining bowel preparation quality. To evaluate the influence of the preparation-to-colonoscopy (PC) interval (the interval of time between the last polyethylene glycol dose ingestion and the start of the colonoscopy) on bowel preparation quality in the split-dose method for colonoscopy. Prospective observational study. University medical center. A total of 366 consecutive outpatients undergoing colonoscopy. Split-dose bowel preparation and colonoscopy. The quality of bowel preparation was assessed by using the Ottawa Bowel Preparation Scale according to the PC interval, and other factors that might influence bowel preparation quality were analyzed. Colonoscopies with a PC interval of 3 to 5 hours had the best bowel preparation quality score in the whole, right, mid, and rectosigmoid colon according to the Ottawa Bowel Preparation Scale. In multivariate analysis, the PC interval (odds ratio [OR] 1.85; 95% CI, 1.18-2.86), the amount of PEG ingested (OR 4.34; 95% CI, 1.08-16.66), and compliance with diet instructions (OR 2.22l 95% CI, 1.33-3.70) were significant contributors to satisfactory bowel preparation. Nonrandomized controlled, single-center trial. The optimal time interval between the last dose of the agent and the start of colonoscopy is one of the important factors to determine satisfactory bowel preparation quality in split-dose polyethylene glycol bowel preparation. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  10. Improving the Yield of Histological Sampling in Patients With Suspected Colorectal Cancer During Colonoscopy by Introducing a Colonoscopy Quality Assurance Program.

    PubMed

    Gado, Ahmed; Ebeid, Basel; Abdelmohsen, Aida; Axon, Anthony

    2011-08-01

    Masses discovered by clinical examination, imaging or endoscopic studies that are suspicious for malignancy typically require biopsy confirmation before treatment is initiated. Biopsy specimens may fail to yield a definitive diagnosis if the lesion is extensively ulcerated or otherwise necrotic and viable tumor tissue is not obtained on sampling. The diagnostic yield is improved when multiple biopsy samples (BSs) are taken. A colonoscopy quality-assurance program (CQAP) was instituted in 2003 in our institution. The aim of this study was to determine the effect of instituting a CQAP on the yield of histological sampling in patients with suspected colorectal cancer (CRC) during colonoscopy. Initial assessment of colonoscopy practice was performed in 2003. A total of five patients with suspected CRC during colonoscopy were documented in 2003. BSs confirmed CRC in three (60%) patients and were nondiagnostic in two (40%). A quality-improvement process was instituted which required a minimum six BSs with adequate size of the samples from any suspected CRC during colonoscopy. A total of 37 patients for the period 2004-2010 were prospectively assessed. The diagnosis of CRC was confirmed with histological examination of BSs obtained during colonoscopy in 63% of patients in 2004, 60% in 2005, 50% in 2006, 67% in 2007, 100% in 2008, 67% in 2009 and 100% in 2010. The yield of histological sampling increased significantly ( p <0.02) from 61% in 2004-2007 to 92% in 2008-2010. The implementation of a quality assurance and improvement program increased the yield of histological sampling in patients with suspected CRC during colonoscopy.

  11. Virtual nonenhanced dual-energy CT urography with tin-filter technology: determinants of detection of urinary calculi in the renal collecting system.

    PubMed

    Mangold, Stefanie; Thomas, Christoph; Fenchel, Michael; Vuust, Morten; Krauss, Bernhard; Ketelsen, Dominik; Tsiflikas, Ilias; Claussen, Claus D; Heuschmid, Martin

    2012-07-01

    To retrospectively determine which features of urinary calculi are associated with their detection after virtual elimination of contrast medium at dual-energy computed tomographic (CT) urography by using a novel tin filter. The institutional ethics committee approved this retrospective study, with waiver of informed consent. A total of 152 patients were examined with single-energy nonenhanced CT and dual-energy CT urography in the excretory phase (either 140 and 80 kV [n=44] or 140 and 100 kV [n=108], with tin filtration at 140 kV). The contrast medium in the renal pelvis and ureters was virtually removed from excretory phase images by using postprocessing software, resulting in virtual nonenhanced (VNE) images. The sensitivity regarding the detection of calculi on VNE images compared with true nonenhanced (TNE) images was determined, and interrater agreement was evaluated by using the Cohen k test. By using logistic regression, the influences of image noise, attenuation, and stone size, as well as attenuation of the contrast medium, on the stone detection rate were assessed. Threshold values with maximal sensitivity and specificity were calculated by means of receiver operating characteristic analyses. Eighty-seven stones were detected on TNE images; 46 calculi were identified on VNE images (sensitivity, 52.9%). Interrater agreement revealed a κ value of 0.95 with TNE images and 0.91 with VNE data. Size (long-axis diameter, P=.005; short-axis diameter, P=.041) and attenuation (P=.0005) of the calculi and image noise (P=.0031) were significantly associated with the detection rate on VNE images. As threshold values, size larger than 2.9 mm, maximum attenuation of the calculi greater than 387 HU, and image noise less than 20 HU were found. After virtual elimination of contrast medium, large (>2.9 mm) and high-attenuation (>387 HU) calculi can be detected with good reliability; smaller and lower attenuation calculi might be erased from images, especially with increased image noise. © RSNA, 2012.

  12. Severe Unresponsive Hypoglycemia Associated with Neuroendocrine Tumor of Unknown Primary Site - 18 Years after Rectal Cancer Surgery. Case Report.

    PubMed

    Rusu, Octavia Cristina; Costea, Radu Virgil; Popa, Cristian Constantin; Iliesiu, Andreea; Dumitru, Adrian; Becheanu, Gabriel; Neagu, Stefan Ilie

    2015-09-01

    Neuroendocrine tumors are derived from cells that have the unique ability to synthesize, store and secrete a variety of metabolically active substances, peptides and amines, characteristic of the tissue of origin, which can cause distinct clinical syndromes. We present the case of a 58-year-old patient diagnosed and surgically treated in January 1996 for stage III inferior rectal cancer, who was readmitted after 18 years presenting persistent diarrheic syndrome and asthenia. Investigations performed (abdominal CT) showed multiple liver metastases, initially suspected as being related to the rectal cancer. Biopsy of liver metastases and pathological and immunohistochemical analysis demonstrated the neuroendocrine origin (moderately differentiated neuroendocrine tumor). Seven months after the identification of liver metastases and after initiation of oncological therapy with Interferon and Somatostatin, the patient presented severe hypoglycemia (serum glucose 13-70 mg/dl) proved to be due to insulin-like factors (serum insulin level 64.9 ìU/ml) secreted by metastases. Due to the aggressive evolution of neuroendocrine tumor, with multiple episodes of severe hypoglycemia, resistant to treatment, the patient died approximately one month after the occurrence of hypoglycemic episodes. Despite comprehensive tests (abdominal CT scan, colonoscopy, bone scintigraphy and PET/CT), the primary site of the neuroendocrine tumors remained unknown.

  13. Pneumothorax, pneumomediastinum, pneumoperitoneum, pneumoretroperitoneum and subcutaneous emphysema following diagnostic colonoscopy.

    PubMed

    Marwan, K; Farmer, K C; Varley, C; Chapple, K S

    2007-07-01

    Colonic perforation is an unusual complication of colonoscopy. We present a case of pneumothorax, pneumomediastinum, pneumoperitoneum and extensive subcutaneous emphysema resulting from a diagnostic colonoscopy. To our knowledge, only two such cases have been described previously.

  14. Natural Language Processing As an Alternative to Manual Reporting of Colonoscopy Quality Metrics

    PubMed Central

    RAJU, GOTTUMUKKALA S.; LUM, PHILLIP J.; SLACK, REBECCA; THIRUMURTHI, SELVI; LYNCH, PATRICK M.; MILLER, ETHAN; WESTON, BRIAN R.; DAVILA, MARTA L.; BHUTANI, MANOOP S.; SHAFI, MEHNAZ A.; BRESALIER, ROBERT S.; DEKOVICH, ALEXANDER A.; LEE, JEFFREY H.; GUHA, SUSHOVAN; PANDE, MALA; BLECHACZ, BORIS; RASHID, ASIF; ROUTBORT, MARK; SHUTTLESWORTH, GLADIS; MISHRA, LOPA; STROEHLEIN, JOHN R.; ROSS, WILLIAM A.

    2015-01-01

    BACKGROUND & AIMS The adenoma detection rate (ADR) is a quality metric tied to interval colon cancer occurrence. However, manual extraction of data to calculate and track the ADR in clinical practice is labor-intensive. To overcome this difficulty, we developed a natural language processing (NLP) method to identify patients, who underwent their first screening colonoscopy, identify adenomas and sessile serrated adenomas (SSA). We compared the NLP generated results with that of manual data extraction to test the accuracy of NLP, and report on colonoscopy quality metrics using NLP. METHODS Identification of screening colonoscopies using NLP was compared with that using the manual method for 12,748 patients who underwent colonoscopies from July 2010 to February 2013. Also, identification of adenomas and SSAs using NLP was compared with that using the manual method with 2259 matched patient records. Colonoscopy ADRs using these methods were generated for each physician. RESULTS NLP correctly identified 91.3% of the screening examinations, whereas the manual method identified 87.8% of them. Both the manual method and NLP correctly identified examinations of patients with adenomas and SSAs in the matched records almost perfectly. Both NLP and manual method produce comparable values for ADR for each endoscopist as well as the group as a whole. CONCLUSIONS NLP can correctly identify screening colonoscopies, accurately identify adenomas and SSAs in a pathology database, and provide real-time quality metrics for colonoscopy. PMID:25910665

  15. Do patients undergo prostate examination while having a colonoscopy?

    PubMed

    Hammett, Tess; Hookey, Lawrence C; Kawakami, Jun

    2009-01-01

    To determine the rate at which physicians report performing a digital rectal examination and comment on the prostate gland before performing colonoscopy in men 50 to 70 years of age. A retrospective chart review of all men 50 to 70 years of age who had a colonoscopy in Kingston, Ontario, in 2005 was completed. It was noted whether each physician described performing a digital rectal examination before the colonoscopy, and if so, whether he or she commented on the prostate. In 2005, 846 eligible colonoscopies were performed by 17 physicians in Kingston, Ontario. In 29.2% of cases, the physician made no comment about having performed a digital rectal examination; in 55.8% of cases, the physician commented on having completed a digital rectal examination but said nothing about the prostate; and in 15.0% of cases, the physician made a comment regarding the prostate. No physician consistently commented on the prostate for all patients, and in no circumstances was direct referral to another physician or follow-up suggested. A colonoscopy presents an ideal opportunity for physicians to use a digital rectal examination to assess for prostate cancer. Physicians performing colonoscopies in men 50 to 70 years of age should pay special attention to the prostate while performing a digital rectal examination before colonoscopy. This novel concept may help maximize resources for cancer screening and could potentially increase the detection rate of clinically palpable prostate cancer.

  16. Associations of Mental Health and Physical Function with Colonoscopy-related Pain.

    PubMed

    Yamada, Eiji; Watanabe, Seitaro; Nakajima, Atsushi

    2017-01-01

    Objective To clarify the effects of mental health and physical function in association with colonoscopy-related pain. Methods The mental health and physical function were evaluated using the Japanese version of the SF-8 Health Survey questionnaire. Poor physical status was defined as a physical component summary (PCS) <40 and poor mental status as a mental component summary (MCS) <40. Pain was assessed using a visual analogue scale (VAS), with significant pain defined as VAS ≥70 mm and insignificant pain as VAS <70 mm. The background and colonoscopic findings were compared in patients with significant and insignificant pain. Patients This study evaluated consecutive Japanese patients who were positive on fecal occult blood tests and underwent total colonoscopy. Results Of the 100 patients, 23 had significant and 77 had insignificant colonoscopy-related pain. A multiple logistic regression analysis showed that MCS <40 [odds ratio (OR) 6.03; 95% confidence interval (CI) 1.41-25.9, p=0.0156], PCS <40 (OR 5.96; 95% CI 1.45-24.5, p=0.0133), and ≥300 seconds to reach the cecum (OR 4.13; 95% CI 1.16-14.7, p=0.0281) were independent risk factors for colonoscopy-related pain. Conclusion The mental health and physical function are important determinants of colonoscopy-related pain. Evaluating the mental health and physical function of patients prior to colonoscopy may effectively predict the degree of colonoscopy-related pain.

  17. Colonoscopy in automated peritoneal dialysis patients: value of prophylactic antibiotics: a prospective study on a single antibiotic.

    PubMed

    Al-Hwiesh, Abdullah K; Abdul-Rahman, Ibrahiem S; Hussameldeen, Mohammad A; Al-Audah, Nadia; Abdelrahman, Abdalla; Moaigel, Hala M; El-Salamony, Tamer; Noor, Abdul-Salam; Al-Osail, Aisha; Al-Sayel, Dalal; Al-Dossari, Nourah

    2017-10-13

    To evaluate the need for prophylactic antibiotics in automated peritoneal dialysis (APD) patients undergoing flexible colonoscopy. A total of 93 patients on automated peritoneal dialysis (APD) undergoing diagnostic colonoscopy were enrolled in a prospective, randomized study. Patients were randomized into 2 age- and sex-matched groups; group A (46 patients) with intraperitoneal (IP) ceftazidime prior to colonoscopy and group B (47 patients) without prophylactic antibiotics. The relations between peritonitis and different parameters were analyzed. Of all colonoscopies, 60.2% showed normal findings, 17.2% with colonic polyps at different sites, 12.9% with angiodysplastic-like lesions, 5.4% with colonic ulcer(s), 3.2% with diverticulae without diverticulitis and 1.1% had transverse colon stricture. Post-colonoscopy peritonitis was documented in 3 (6.5%) and 4 (8.5%) patients in groups A and B, respectively (p = 0.2742); the causative organisms were mainly gram negative bacteria. Polypectomy was not associated with increased peritonitis episodes. By multiple logistic regression analysis, diabetes mellitus was the only independent variable that entered into the best predictive equation over the development of post-colonoscopy peritonitis but not antibiotic use. The relation between prophylactic antibiotic use prior to colonoscopy in APD patients and the risk of peritonitis was lacking. Only diabetes mellitus appears to be of significance. Polypectomy did not increase peritonitis episodes.

  18. Geometrical analysis of woven fabric microstructure based on micron-resolution computed tomography data

    NASA Astrophysics Data System (ADS)

    Krieger, Helga; Seide, Gunnar; Gries, Thomas; Stapleton, Scott E.

    2018-04-01

    The global mechanical properties of textiles such as elasticity and strength, as well as transport properties such as permeability depend strongly on the microstructure of the textile. Textiles are heterogeneous structures with highly anisotropic material properties, including local fiber orientation and local fiber volume fraction. In this paper, an algorithm is presented to generate a virtual 3D-model of a woven fabric architecture with information about the local fiber orientation and the local fiber volume fraction. The geometric data of the woven fabric impregnated with resin was obtained by micron-resolution computed tomography (μCT). The volumetric μCT-scan was discretized into cells and the microstructure of each cell was analyzed and homogenized. Furthermore, the discretized data was used to calculate the local permeability tensors of each cell. An example application of the analyzed data is the simulation of the resin flow through a woven fabric based on the determined local permeability tensors and on Darcy's law. The presented algorithm is an automated and robust method of going from μCT-scans to structural or flow models.

  19. Pneumothorax, Pneumomediastinum, Pneumoperitoneum, Pneumoretroperitoneum and Subcutaneous Emphysema Following Diagnostic Colonoscopy

    PubMed Central

    Marwan, K; Farmer, KC; Varley, C; Chapple, KS

    2007-01-01

    Colonic perforation is an unusual complication of colonoscopy. We present a case of pneumothorax, pneumomediastinum, pneumoperitoneum and extensive subcutaneous emphysema resulting from a diagnostic colonoscopy. To our knowledge, only two such cases have been described previously. PMID:17688713

  20. The Delivery of Business Courses via the African Virtual University: A Case Study

    ERIC Educational Resources Information Center

    Graber, Mark; Bolt, Susan

    2011-01-01

    In this case study the delivery of business courses as a result of the partnership between the African Virtual University (AVU) and Curtin University in Western Australia is described. From 2004 to 2008, degree and diploma business courses were delivered using WebCT in the four AVU partner locations: Addis Ababa University (Ethiopia), Kigali…

  1. WE-FG-207B-09: Experimental Assessment of Noise and Spatial Resolution in Virtual Non-Contrast Dual-Energy CT Images Across Multiple Patient Sizes and CT Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montoya, J; Ferrero, A; Yu, L

    Purpose: To investigate the noise and spatial resolution properties of virtual non-contrast (VNC) dual-energy CT images compared to true non-contrast (TNC) images across multiple patient sizes and CT systems. Methods: Torso-shaped water phantoms with lateral widths of 25, 30, 35, 40 and 45 cm and a high resolution bar pattern phantom (Catphan CTP528) were scanned using 2nd and 3rd generation dual-source CT systems (Scanner A: Somatom Definition Flash, Scanner B: Somatom Force, Siemens Healthcare) in dual-energy scan mode with the same radiation dose for a given phantom size. Tube potentials of 80/Sn140 and 100/Sn140 on Scanner A and 80/Sn150, 90/Sn150more » and 100/Sn150 on Scanner B were evaluated to examine the impact of spectral separation. Images were reconstructed using a medium sharp quantitative kernel (Qr40), 1.0-mm thickness, 1.0-mm interval and 20 cm field of view. Mixed images served as TNC images. VNC images were created using commercial software (Virtual Unenhanced, Syngo VIA Version VA30, Siemens Healthcare). The noise power spectrum (NPS), area under the NPS, peak frequency of the NPS and image noise were measured for every phantom size and tube potential combination in TNC and VNC images. Results were compared within and between CT systems. Results: Minimal shift in NPS peak frequencies was observed in VNC images compared to TNC for NPS having pronounced peaks. Image noise and area under the NPS were higher in VNC images compared to TNC images across all tube potentials and for scanner A compared to scanner B. Limiting spatial resolution was deemed to be identical between VNC and TNC images. Conclusion: Quantitative assessment of image quality in VNC images demonstrated higher noise but equivalent spatial resolution compared to TNC images. Decreased noise was observed in the 3rd generation dual-source CT system for tube potential pairs having greater spectral separation. Dr. McCollough receives research support from Siemens Healthcare.« less

  2. Feasibility and validation of virtual autopsy for dental identification using the Interpol dental codes.

    PubMed

    Franco, Ademir; Thevissen, Patrick; Coudyzer, Walter; Develter, Wim; Van de Voorde, Wim; Oyen, Raymond; Vandermeulen, Dirk; Jacobs, Reinhilde; Willems, Guy

    2013-05-01

    Virtual autopsy is a medical imaging technique, using full body computed tomography (CT), allowing for a noninvasive and permanent observation of all body parts. For dental identification clinically and radiologically observed ante-mortem (AM) and post-mortem (PM) oral identifiers are compared. The study aimed to verify if a PM dental charting can be performed on virtual reconstructions of full-body CT's using the Interpol dental codes. A sample of 103 PM full-body CT's was collected from the forensic autopsy files of the Department of Forensic Medicine University Hospitals, KU Leuven, Belgium. For validation purposes, 3 of these bodies underwent a complete dental autopsy, a dental radiological and a full-body CT examination. The bodies were scanned in a Siemens Definition Flash CT Scanner (Siemens Medical Solutions, Germany). The images were examined on 8- and 12-bit screen resolution as three-dimensional (3D) reconstructions and as axial, coronal and sagittal slices. InSpace(®) (Siemens Medical Solutions, Germany) software was used for 3D reconstruction. The dental identifiers were charted on pink PM Interpol forms (F1, F2), using the related dental codes. Optimal dental charting was obtained by combining observations on 3D reconstructions and CT slices. It was not feasible to differentiate between different kinds of dental restoration materials. The 12-bit resolution enabled to collect more detailed evidences, mainly related to positions within a tooth. Oral identifiers, not implemented in the Interpol dental coding were observed. Amongst these, the observed (3D) morphological features of dental and maxillofacial structures are important identifiers. The latter can become particularly more relevant towards the future, not only because of the inherent spatial features, yet also because of the increasing preventive dental treatment, and the decreasing application of dental restorations. In conclusion, PM full-body CT examinations need to be implemented in the PM dental charting protocols and the Interpol dental codes should be adapted accordingly. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  3. Impact of fair bowel preparation quality on adenoma and serrated polyp detection: data from the New Hampshire colonoscopy registry by using a standardized preparation-quality rating.

    PubMed

    Anderson, Joseph C; Butterly, Lynn F; Robinson, Christina M; Goodrich, Martha; Weiss, Julia E

    2014-09-01

    The effect of colon preparation quality on adenoma detection rates (ADRs) is unclear, partly because of lack of uniform colon preparation ratings in prior studies. The New Hampshire Colonoscopy Registry collects detailed data from colonoscopies statewide, by using a uniform preparation quality scale after the endoscopist has cleaned the mucosa. To compare the overall and proximal ADR and serrated polyp detection rates (SDR) in colonoscopies with differing levels of colon preparation quality. Cross-sectional. New Hampshire statewide registry. Patients undergoing colonoscopy. We examined colon preparation quality for 13,022 colonoscopies, graded by using specific descriptions provided to endoscopists. ADR and SDR are the number of colonoscopies with at least 1 adenoma or serrated polyp (excluding those in the rectum and/or sigmoid colon) detected divided by the total number of colonoscopies, for the preparation categories: optimal (excellent and/or good), fair, and poor. Overall/proximal ADR/SDR. The overall detection rates in examinations with fair colon preparation quality (SDR 8.9%; 95% confidence interval [CI], 7.4-10.7, ADR 27.1%; 95% CI, 24.6-30.0) were similar to rates observed in colonoscopies with optimal preparation quality (SDR 8.8%; 95% CI, 8.3-9.4, ADR 26.3%; 95% CI, 25.6-27.2). This finding also was observed for rates in the proximal colon. A logistic regression model (including withdrawal time) found that proximal ADR was statistically lower in the poor preparation category (odds ratio 0.45; 95% CI, 0.24-0.84; P < .01) than in adequately prepared colons. Homogeneous population. In our sample, there was no significant difference in overall or proximal ADR or SDR between colonoscopies with fair versus optimal colon preparation quality. Poor colon preparation quality may reduce the proximal ADR. Published by Mosby, Inc.

  4. The Polyp Manager: a new tool for optimal polyp documentation during colonoscopy. A pilot study.

    PubMed Central

    van de Meeberg, Maartje M.; Ouwendijk, Rob J. Th.; ter Borg, Pieter C. J.; van den Hazel, Sven J.; van de Meeberg, Paul C.

    2016-01-01

    Background and study aims: Conventional reporting of polyps is often incomplete. We tested the Polyp Manager (PM), a new software application permitting the endoscopist to document polyps in real time during colonoscopy. We studied completeness of polyp descriptions, user-friendliness and the potential time benefit. Patients and methods: In two Dutch hospitals colonoscopies were performed with PM (as a touchscreen endoscopist-operated device or nurse-operated desktop application). Completeness of polyp descriptions was compared to a historical group with conventional reporting (CRH). Prospectively, we compared user-friendliness (VAS-scores) and time benefit of the endoscopist-operated PM to conventional reporting (CR) in one hospital. Duration of colonoscopy and time needed to report polyps and provide a pathology request were measured. Provided that using PM does not prolong colonoscopy, the sum of the latter two was considered as a potential time-benefit if the PM were fully integrated into a digital reporting system. Results: A total of 144 regular colonoscopies were included in the study. Both groups were comparable with regard to patient characteristics, duration of colonoscopy and number of polyps. Using the PM did reduce incomplete documentation of the following items in CRH-reports: location (96 % vs 82 %, P = 0.01), size (95 % vs 89 %, P = 0.03), aspect (71 % vs 36 %, P < 0.001) and completeness of removal (61 % vs 37 %, P < 0.001). In the prospective study 23 PM-colonoscopies where compared to 28 CR-colonoscopies. VAS-scores were significantly higher in the endoscopist-operated PM group. Time to report was 01:27 ± 01:43 minutes (median + interquartile range) in the entire group (PM as CR), reflecting potential time benefit per colonoscopy. Conclusions: The PM is a user-friendly tool that seems to improve completeness of polyp reporting. Once integrated with digital reporting systems, it is probably time saving as well. PMID:27227117

  5. Knowledge and attitudes of primary healthcare patients regarding population-based screening for colorectal cancer.

    PubMed

    Ramos, Maria; Llagostera, Maria; Esteva, Magdalena; Cabeza, Elena; Cantero, Xavier; Segarra, Manel; Martín-Rabadán, Maria; Artigues, Guillem; Torrent, Maties; Taltavull, Joana Maria; Vanrell, Joana Maria; Marzo, Mercè; Llobera, Joan

    2011-09-25

    ABSTRACT: BACKGROUND: The aim of this study was to assess the extent of knowledge of primary health care (PHC) patients about colorectal cancer (CRC), their attitudes toward population-based screening for this disease and gender differences in these respects. METHODS: A questionnaire-based survey of PHC patients in the Balearic Islands and some districts of the metropolitan area of Barcelona was conducted. Individuals between 50 and 69 years of age with no history of CRC were interviewed at their PHC centers. RESULTS: We analyzed the results of 625 questionnaires, 58% of which were completed by women. Most patients believed that cancer diagnosis before symptom onset improved the chance of survival. More women than men knew the main symptoms of CRC. A total of 88.8% of patients reported that they would perform the fecal occult blood test (FOBT) for CRC screening if so requested by PHC doctors or nurses. If the FOBT was positive and a colonoscopy was offered, 84.9% of participants indicated that they would undergo the procedure, and no significant difference by gender was apparent. Fear of having cancer was the main reason for performance of an FOBT, and also for not performing the FOBT, especially in women. Fear of pain was the main reason for not wishing to undergo colonoscopy. Factors associated with reluctance to perform the FOBT were: (i) the idea that that many forms of cancer can be prevented by exercise and, (ii) a reluctance to undergo colonoscopy if an FOBT was positive. Factors associated with reluctance to undergo colonoscopy were: (i) residence in Barcelona, (ii) ignorance of the fact that early diagnosis of CRC is associated with better prognosis, (iii) no previous history of colonoscopy, and (iv) no intention to perform the FOBT for CRC screening. CONCLUSION: We identified gaps in knowledge about CRC and prevention thereof in PHC patients from the Balearic Islands and the Barcelona region of Spain. If fears about CRC screening, and CRC per se, are addressed, and if it is emphasized that CRC is preventable, participation in CRC screening programs may improve.

  6. The role of colonoscopy in managing diverticular disease of the colon.

    PubMed

    Tursi, Antonio

    2015-03-01

    Diverticulosis of the colon is frequently found on routine colonoscopy, and the incidence of diverticular disease and its complications appears to be increasing. The role of colonoscopy in managing this disease is still controversial. Colonoscopy plays a key role in managing diverticular bleeding. Several techniques have been effectively used in this field, but band ligation seems to be the best in preventing rebleeding. Colonoscopy is also effective in posing a correct differential diagnosis with other forms of chronic colitis involving colon harbouring diverticula (in particular with Crohn's disease or Segmental Colitis Associated with Diverticulosis). The role of colonoscopy to confirm diagnosis of uncomplicated diverticulitis is still under debate, since the risk of advanced colonic neoplasia in patients admitted for acute uncomplicated diverticulitis is not increased as compared to the average-risk population. On the contrary, colonoscopy is mandatory if patients complain of persistent symptoms or after resolution of an episode of complicated diverticulitis. Finally, a recent endoscopic classification, called Diverticular Inflammation and Complications Assessment (DICA), has been developed and validated. This classification seems to be a promising tool for predicting the outcome of the colon harboring diverticula, but further, prospective studies have to confirm its predictive role on the outcome of the disease.

  7. Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm.

    PubMed

    Woo, Jaehong; Choi, Jae Hyuk; Seo, Jong Tae; Kim, Tae Il; Yi, Byung Ju

    2017-01-01

    Colonoscopy is one of the most effective diagnostic and therapeutic tools for colorectal diseases. We aim to propose a master-slave robotic colonoscopy that is controllable in remote site using conventional colonoscopy. The master and slave robot were developed to use conventional flexible colonoscopy. The robotic colonoscopic procedure was performed using a colonoscope training model by one expert endoscopist and two unexperienced engineers. To provide the haptic sensation, the insertion force and the rotating torque were measured and sent to the master robot. A slave robot was developed to hold the colonoscopy and its knob, and perform insertion, rotation, and two tilting motions of colonoscope. A master robot was designed to teach motions of the slave robot. These measured force and torque were scaled down by one tenth to provide the operator with some reflection force and torque at the haptic device. The haptic sensation and feedback system was successful and helpful to feel the constrained force or torque in colon. The insertion time using robotic system decreased with repeated procedures. This work proposed a robotic approach for colonoscopy using haptic feedback algorithm, and this robotic device would effectively perform colonoscopy with reduced burden and comparable safety for patients in remote site.

  8. Bowel Prep Quality in Patients of Low Socioeconomic Status Undergoing Screening Colonoscopy With Patient Navigation.

    PubMed

    Miller, Sarah Johanna; Itzkowitz, Steven H; Shah, Brijen; Jandorf, Lina

    2016-10-01

    The effectiveness of colonoscopy is directly affected by the quality of the patient's bowel preparation. Patients with lower socioeconomic status (SES) are at increased risk of having suboptimal bowel prep quality. Patient navigators can play a key role in clarifying bowel prep instructions. The aim of the present study was to examine the quality of bowel prep and its predictors among individuals of low SES undergoing screening colonoscopy with patient navigation. Participants (N = 607) were individuals of low SES who completed a screening colonoscopy with patient navigation. Demographic information was collected after the participants received a primary care referral for a screening colonoscopy. After the colonoscopy was completed, medical charts were reviewed to document the colonoscopists' bowel prep quality ratings. A total of 6.8% (41/607) of the sample had poor bowel prep, which significantly correlated with having a colonoscopy that did not reach the cecum. If fair preps were included, approximately 19.3% (117/607) of our cohort would be considered to have suboptimal bowel prep. Our suboptimal bowel prep rates were better than those reported from other low SES samples. © 2015 Society for Public Health Education.

  9. Image Retrieval Method for Multiscale Objects from Optical Colonoscopy Images

    PubMed Central

    Sakanashi, Hidenori; Takahashi, Eiichi; Murakawa, Masahiro; Aoki, Hiroshi; Takeuchi, Ken; Suzuki, Yasuo

    2017-01-01

    Optical colonoscopy is the most common approach to diagnosing bowel diseases through direct colon and rectum inspections. Periodic optical colonoscopy examinations are particularly important for detecting cancers at early stages while still treatable. However, diagnostic accuracy is highly dependent on both the experience and knowledge of the medical doctor. Moreover, it is extremely difficult, even for specialist doctors, to detect the early stages of cancer when obscured by inflammations of the colonic mucosa due to intractable inflammatory bowel diseases, such as ulcerative colitis. Thus, to assist the UC diagnosis, it is necessary to develop a new technology that can retrieve similar cases of diagnostic target image from cases in the past that stored the diagnosed images with various symptoms of colonic mucosa. In order to assist diagnoses with optical colonoscopy, this paper proposes a retrieval method for colonoscopy images that can cope with multiscale objects. The proposed method can retrieve similar colonoscopy images despite varying visible sizes of the target objects. Through three experiments conducted with real clinical colonoscopy images, we demonstrate that the method is able to retrieve objects of any visible size and any location at a high level of accuracy. PMID:28255295

  10. Image Retrieval Method for Multiscale Objects from Optical Colonoscopy Images.

    PubMed

    Nosato, Hirokazu; Sakanashi, Hidenori; Takahashi, Eiichi; Murakawa, Masahiro; Aoki, Hiroshi; Takeuchi, Ken; Suzuki, Yasuo

    2017-01-01

    Optical colonoscopy is the most common approach to diagnosing bowel diseases through direct colon and rectum inspections. Periodic optical colonoscopy examinations are particularly important for detecting cancers at early stages while still treatable. However, diagnostic accuracy is highly dependent on both the experience and knowledge of the medical doctor. Moreover, it is extremely difficult, even for specialist doctors, to detect the early stages of cancer when obscured by inflammations of the colonic mucosa due to intractable inflammatory bowel diseases, such as ulcerative colitis. Thus, to assist the UC diagnosis, it is necessary to develop a new technology that can retrieve similar cases of diagnostic target image from cases in the past that stored the diagnosed images with various symptoms of colonic mucosa. In order to assist diagnoses with optical colonoscopy, this paper proposes a retrieval method for colonoscopy images that can cope with multiscale objects. The proposed method can retrieve similar colonoscopy images despite varying visible sizes of the target objects. Through three experiments conducted with real clinical colonoscopy images, we demonstrate that the method is able to retrieve objects of any visible size and any location at a high level of accuracy.

  11. First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veiga, Catarina; Janssens, Guillaume; Teng, Ching-Ling

    2016-05-01

    Purpose: An adaptive proton therapy workflow using cone beam computed tomography (CBCT) is proposed. It consists of an online evaluation of a fast range-corrected dose distribution based on a virtual CT (vCT) scan. This can be followed by more accurate offline dose recalculation on the vCT scan, which can trigger a rescan CT (rCT) for replanning. Methods and Materials: The workflow was tested retrospectively for 20 consecutive lung cancer patients. A diffeomorphic Morphon algorithm was used to generate the lung vCT by deforming the average planning CT onto the CBCT scan. An additional correction step was applied to account formore » anatomic modifications that cannot be modeled by deformation alone. A set of clinical indicators for replanning were generated according to the water equivalent thickness (WET) and dose statistics and compared with those obtained on the rCT scan. The fast dose approximation consisted of warping the initial planned dose onto the vCT scan according to the changes in WET. The potential under- and over-ranges were assessed as a variation in WET at the target's distal surface. Results: The range-corrected dose from the vCT scan reproduced clinical indicators similar to those of the rCT scan. The workflow performed well under different clinical scenarios, including atelectasis, lung reinflation, and different types of tumor response. Between the vCT and rCT scans, we found a difference in the measured 95% percentile of the over-range distribution of 3.4 ± 2.7 mm. The limitations of the technique consisted of inherent uncertainties in deformable registration and the drawbacks of CBCT imaging. The correction step was adequate when gross errors occurred but could not recover subtle anatomic or density changes in tumors with complex topology. Conclusions: A proton therapy workflow based on CBCT provided clinical indicators similar to those using rCT for patients with lung cancer with considerable anatomic changes.« less

  12. Importance of reporting segmental bowel preparation scores during colonoscopy in clinical practice

    PubMed Central

    Jain, Deepanshu; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury; Singhal, Shashideep

    2015-01-01

    AIM: To evaluate the impact of reporting bowel preparation using Boston Bowel Preparation Scale (BBPS) in clinical practice. METHODS: The study was a prospective observational cohort study which enrolled subjects reporting for screening colonoscopy. All subjects received a gallon of polyethylene glycol as bowel preparation regimen. After colonoscopy the endoscopists determined quality of bowel preparation using BBPS. Segmental scores were combined to calculate composite BBPS. Site and size of the polyps detected was recorded. Pathology reports were reviewed to determine advanced adenoma detection rates (AADR). Segmental AADR’s were calculated and categorized based on the segmental BBPS to determine the differential impact of bowel prep on AADR. RESULTS: Three hundred and sixty subjects were enrolled in the study with a mean age of 59.2 years, 36.3% males and 63.8% females. Four subjects with incomplete colonoscopy due BBPS of 0 in any segment were excluded. Based on composite BBPS subjects were divided into 3 groups; Group-0 (poor bowel prep, BBPS 0-3) n = 26 (7.3%), Group-1 (Suboptimal bowel prep, BBPS 4-6) n = 121 (34%) and Group-2 (Adequate bowel prep, BBPS 7-9) n = 209 (58.7%). AADR showed a linear trend through Group-1 to 3; with an AADR of 3.8%, 14.8% and 16.7% respectively. Also seen was a linear increasing trend in segmental AADR with improvement in segmental BBPS. There was statistical significant difference between AADR among Group 0 and 2 (3.8% vs 16.7%, P < 0.05), Group 1 and 2 (14.8% vs 16.7%, P < 0.05) and Group 0 and 1 (3.8% vs 14.8%, P < 0.05). χ2 method was used to compute P value for determining statistical significance. CONCLUSION: Segmental AADRs correlate with segmental BBPS. It is thus valuable to report segmental BBPS in colonoscopy reports in clinical practice. PMID:25852286

  13. Importance of reporting segmental bowel preparation scores during colonoscopy in clinical practice.

    PubMed

    Jain, Deepanshu; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury; Singhal, Shashideep

    2015-04-07

    To evaluate the impact of reporting bowel preparation using Boston Bowel Preparation Scale (BBPS) in clinical practice. The study was a prospective observational cohort study which enrolled subjects reporting for screening colonoscopy. All subjects received a gallon of polyethylene glycol as bowel preparation regimen. After colonoscopy the endoscopists determined quality of bowel preparation using BBPS. Segmental scores were combined to calculate composite BBPS. Site and size of the polyps detected was recorded. Pathology reports were reviewed to determine advanced adenoma detection rates (AADR). Segmental AADR's were calculated and categorized based on the segmental BBPS to determine the differential impact of bowel prep on AADR. Three hundred and sixty subjects were enrolled in the study with a mean age of 59.2 years, 36.3% males and 63.8% females. Four subjects with incomplete colonoscopy due BBPS of 0 in any segment were excluded. Based on composite BBPS subjects were divided into 3 groups; Group-0 (poor bowel prep, BBPS 0-3) n = 26 (7.3%), Group-1 (Suboptimal bowel prep, BBPS 4-6) n = 121 (34%) and Group-2 (Adequate bowel prep, BBPS 7-9) n = 209 (58.7%). AADR showed a linear trend through Group-1 to 3; with an AADR of 3.8%, 14.8% and 16.7% respectively. Also seen was a linear increasing trend in segmental AADR with improvement in segmental BBPS. There was statistical significant difference between AADR among Group 0 and 2 (3.8% vs 16.7%, P < 0.05), Group 1 and 2 (14.8% vs 16.7%, P < 0.05) and Group 0 and 1 (3.8% vs 14.8%, P < 0.05). χ(2) method was used to compute P value for determining statistical significance. Segmental AADRs correlate with segmental BBPS. It is thus valuable to report segmental BBPS in colonoscopy reports in clinical practice.

  14. Augmented virtuality for arthroscopic knee surgery.

    PubMed

    Li, John M; Bardana, Davide D; Stewart, A James

    2011-01-01

    This paper describes a computer system to visualize the location and alignment of an arthroscope using augmented virtuality. A 3D computer model of the patient's joint (from CT) is shown, along with a model of the tracked arthroscopic probe and the projection of the camera image onto the virtual joint. A user study, using plastic bones instead of live patients, was made to determine the effectiveness of this navigated display; the study showed that the navigated display improves target localization in novice residents.

  15. Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy.

    PubMed

    Sutherland, J G H; Miksys, N; Furutani, K M; Thomson, R M

    2014-01-01

    To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxel and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for (125)I, (103)Pd, and (131)Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue assignment within lung contours are employed in generated phantoms, this erroneous assignment is reduced, generally resulting in higher doses. Lung-constrained tissue assignment also results in increased doses in regions of interest due to a reduction in the erroneous assignment of adipose to voxels within lung contours. Differences in dose metrics calculated for different computational phantoms are sensitive to radionuclide photon spectra with the largest differences for (103)Pd seeds and smallest but still considerable differences for (131)Cs seeds. Despite producing differences in CT images, dose metrics calculated using the STR, fan beam + STR, and 3D median filter techniques produce similar dose metrics. Results suggest that the accuracy of dose distributions for permanent implant lung brachytherapy is improved by applying lung-constrained tissue assignment schemes to metallic artifact corrected images.

  16. [Colonoscopy for early detection and prevention of colorectal cancer].

    PubMed

    Niv, Yaron

    2010-08-01

    Colonoscopy has a limited success in the prevention of colorectal cancer of the right colon. Thus, there is place for improvement. The potential reasons for colonoscopy failure are the different biology of polyps on the right side of the colon or procedure quality. Preparation, withdrawal time, detection of all polyps and their removal using the best technique will overcome this problem. Furthermore, the implementation of a computerized database and report that includes quality assurance fields, will improve colonoscopy success rates.

  17. Estimation of breast dose reduction potential for organ-based tube current modulated CT with wide dose reduction arc

    NASA Astrophysics Data System (ADS)

    Fu, Wanyi; Sturgeon, Gregory M.; Agasthya, Greeshma; Segars, W. Paul; Kapadia, Anuj J.; Samei, Ehsan

    2017-03-01

    This study aimed to estimate the organ dose reduction potential for organ-dose-based tube current modulated (ODM) thoracic CT with wide dose reduction arc. Twenty-one computational anthropomorphic phantoms (XCAT, age range: 27- 75 years, weight range: 52.0-105.8 kg) were used to create a virtual patient population with clinical anatomic variations. For each phantom, two breast tissue compositions were simulated: 50/50 and 20/80 (glandular-to-adipose ratio). A validated Monte Carlo program was used to estimate the organ dose for standard tube current modulation (TCM) (SmartmA, GE Healthcare) and ODM (GE Healthcare) for a commercial CT scanner (Revolution, GE Healthcare) with explicitly modeled tube current modulation profile, scanner geometry, bowtie filtration, and source spectrum. Organ dose was determined using a typical clinical thoracic CT protocol. Both organ dose and CTDIvol-to-organ dose conversion coefficients (h factors) were compared between TCM and ODM. ODM significantly reduced all radiosensitive organ doses (p<0.01). The breast dose was reduced by 30+/-2%. For h factors, organs in the anterior region (e.g. thyroid, stomach) exhibited substantial decreases, and the medial, distributed, and posterior region either saw an increase or no significant change. The organ-dose-based tube current modulation significantly reduced organ doses especially for radiosensitive superficial anterior organs such as the breasts.

  18. Computational replication of the patient-specific stenting procedure for coronary artery bifurcations: From OCT and CT imaging to structural and hemodynamics analyses.

    PubMed

    Chiastra, Claudio; Wu, Wei; Dickerhoff, Benjamin; Aleiou, Ali; Dubini, Gabriele; Otake, Hiromasa; Migliavacca, Francesco; LaDisa, John F

    2016-07-26

    The optimal stenting technique for coronary artery bifurcations is still debated. With additional advances computational simulations can soon be used to compare stent designs or strategies based on verified structural and hemodynamics results in order to identify the optimal solution for each individual's anatomy. In this study, patient-specific simulations of stent deployment were performed for 2 cases to replicate the complete procedure conducted by interventional cardiologists. Subsequent computational fluid dynamics (CFD) analyses were conducted to quantify hemodynamic quantities linked to restenosis. Patient-specific pre-operative models of coronary bifurcations were reconstructed from CT angiography and optical coherence tomography (OCT). Plaque location and composition were estimated from OCT and assigned to models, and structural simulations were performed in Abaqus. Artery geometries after virtual stent expansion of Xience Prime or Nobori stents created in SolidWorks were compared to post-operative geometry from OCT and CT before being extracted and used for CFD simulations in SimVascular. Inflow boundary conditions based on body surface area, and downstream vascular resistances and capacitances were applied at branches to mimic physiology. Artery geometries obtained after virtual expansion were in good agreement with those reconstructed from patient images. Quantitative comparison of the distance between reconstructed and post-stent geometries revealed a maximum difference in area of 20.4%. Adverse indices of wall shear stress were more pronounced for thicker Nobori stents in both patients. These findings verify structural analyses of stent expansion, introduce a workflow to combine software packages for solid and fluid mechanics analysis, and underscore important stent design features from prior idealized studies. The proposed approach may ultimately be useful in determining an optimal choice of stent and position for each patient. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Factors Associated with Adenoma Detection Rate and Diagnosis of Polyps and Colorectal Cancer during Colonoscopy in France: Results of a Prospective, Nationwide Survey

    PubMed Central

    Barret, Maximilien; Boustiere, Christian; Canard, Jean-Marc; Arpurt, Jean-Pierre; Bernardini, David; Bulois, Philippe; Chaussade, Stanislas; Heresbach, Denis; Joly, Isabelle; Lapuelle, Jean; Laugier, René; Lesur, Gilles; Pienkowski, Patrice; Ponchon, Thierry; Pujol, Bertrand; Richard-Molard, Bruno; Robaszkiewicz, Michel; Systchenko, Rémi; Abbas, Fatima; Schott-Pethelaz, Anne-Marie; Cellier, Christophe

    2013-01-01

    Introduction Colonoscopy can prevent deaths due to colorectal cancer (CRC) through early diagnosis or resection of colonic adenomas. We conducted a prospective, nationwide study on colonoscopy practice in France. Methods An online questionnaire was administered to 2,600 French gastroenterologists. Data from all consecutive colonoscopies performed during one week were collected. A statistical extrapolation of the results to a whole year was performed, and factors potentially associated with the adenoma detection rate (ADR) or the diagnosis of polyps or cancer were assessed. Results A total of 342 gastroenterologists, representative of the overall population of French gastroenterologists, provided data on 3,266 colonoscopies, corresponding to 1,200,529 (95% CI: 1,125,936-1,275,122) procedures for the year 2011. The indication for colonoscopy was CRC screening and digestive symptoms in 49.6% and 38.9% of cases, respectively. Polypectomy was performed in 35.5% of cases. The ADR and prevalence of CRC were 17.7% and 2.9%, respectively. The main factors associated with a high ADR were male gender (p=0.0001), age over 50 (p=0.0001), personal or family history of CRC or colorectal polyps (p<0.0001 and p<0.0001, respectively), and positive fecal occult blood test (p=0.0005). The prevalence of CRC was three times higher in patients with their first colonoscopy (4.2% vs. 1.4%; p<0.0001). Conclusions For the first time in France, we report nationwide prospective data on colonoscopy practice, including histological results. We found an average ADR of 17.7%, and observed reduced CRC incidence in patients with previous colonoscopy. PMID:23874822

  20. Factors associated with adenoma detection rate and diagnosis of polyps and colorectal cancer during colonoscopy in France: results of a prospective, nationwide survey.

    PubMed

    Barret, Maximilien; Boustiere, Christian; Canard, Jean-Marc; Arpurt, Jean-Pierre; Bernardini, David; Bulois, Philippe; Chaussade, Stanislas; Heresbach, Denis; Joly, Isabelle; Lapuelle, Jean; Laugier, René; Lesur, Gilles; Pienkowski, Patrice; Ponchon, Thierry; Pujol, Bertrand; Richard-Molard, Bruno; Robaszkiewicz, Michel; Systchenko, Rémi; Abbas, Fatima; Schott-Pethelaz, Anne-Marie; Cellier, Christophe

    2013-01-01

    Colonoscopy can prevent deaths due to colorectal cancer (CRC) through early diagnosis or resection of colonic adenomas. We conducted a prospective, nationwide study on colonoscopy practice in France. An online questionnaire was administered to 2,600 French gastroenterologists. Data from all consecutive colonoscopies performed during one week were collected. A statistical extrapolation of the results to a whole year was performed, and factors potentially associated with the adenoma detection rate (ADR) or the diagnosis of polyps or cancer were assessed. A total of 342 gastroenterologists, representative of the overall population of French gastroenterologists, provided data on 3,266 colonoscopies, corresponding to 1,200,529 (95% CI: 1,125,936-1,275,122) procedures for the year 2011. The indication for colonoscopy was CRC screening and digestive symptoms in 49.6% and 38.9% of cases, respectively. Polypectomy was performed in 35.5% of cases. The ADR and prevalence of CRC were 17.7% and 2.9%, respectively. The main factors associated with a high ADR were male gender (p=0.0001), age over 50 (p=0.0001), personal or family history of CRC or colorectal polyps (p<0.0001 and p<0.0001, respectively), and positive fecal occult blood test (p=0.0005). The prevalence of CRC was three times higher in patients with their first colonoscopy (4.2% vs. 1.4%; p<0.0001). For the first time in France, we report nationwide prospective data on colonoscopy practice, including histological results. We found an average ADR of 17.7%, and observed reduced CRC incidence in patients with previous colonoscopy.

  1. Early Versus Delayed Colonoscopy in Hospitalized Patients With Lower Gastrointestinal Bleeding: A Meta-Analysis.

    PubMed

    Sengupta, Neil; Tapper, Elliot B; Feuerstein, Joseph D

    2017-04-01

    Early colonoscopy is recommended for patients with severe lower gastrointestinal bleeding (LGIB). There is limited data as to whether this is associated with improved outcomes. We performed a meta-analysis of studies comparing early (<24 h) versus delayed colonoscopy (>24 h). PubMed, Embase, and Web of Science were searched for manuscripts using colonoscopy as a diagnostic/treatment modality for patients hospitalized with LGIB. Studies were included if data were available on outcomes comparing early and delayed colonoscopy. Articles were reviewed for time to colonoscopy, rebleeding, mortality, length of stay (LOS), surgery, interventions, localization of LGIB, and number of packed red blood cells. Pooled measures were reported using the Mantel-Haenszel method. A total of 8491 studies were assessed of which 6 were included. There were 422 patients in the early arm and 479 in the delayed arm. There were no differences in age (64.2 vs. 65.7, P=0.85), admission hemoglobin (10.3 vs. 10.3 g/dL, P=0.96), LOS (5.21 vs. 6.09, P=0.52), and packed red blood cells transfusion (2.37 vs. 2.35, P=0.92) between the groups. In hospital mortality [odds ratio (OR), 1.64; 95% confidence interval (CI), 0.51-5.32], rebleeding (OR, 1.38; 95% CI, 0.85-2.23) and need for surgery (OR, 0.89; 95% CI, 0.42-1.89) were not different in delayed versus early colonoscopy. Early colonoscopy was associated with a higher detection of bleeding source (OR, 2.97; 95% CI, 2.11-4.19) and endoscopic intervention (OR, 3.99; 95% CI, 2.59-6.13). Early colonoscopy is not associated with reduced rebleeding, LOS, or surgery but is associated with a higher rate of source localization and endoscopic intervention.

  2. Cardiopulmonary events during primary colonoscopy screening in an average risk population.

    PubMed

    Khalid-de Bakker, C A; Jonkers, D M; Hameeteman, W; de Ridder, R J; Masclee, A A; Stockbrügger, R W

    2011-04-01

    Large colorectal cancer screening studies using primary colonoscopy have reported a low risk of major complications. Studies on diagnostic and therapeutic colonoscopy have pointed to a frequent occurrence of(minor) cardiopulmonary events, and with the steady increase of colonoscopy screening, it is important to investigate their occurrence in colonoscopy screening. This study describes the frequency of bradycardia(pulse rate <60 min-1), hypotension (systolic blood pressure(SB P) <90 mmHg), hypoxaemia (blood oxygenation, SaO2<90%) and ECG changes during colonoscopy screening in an average-risk population (hospital personnel, n=214,mean age 54.0±3.8, 39.3% male), without significant comorbidity) and aims at identifying subject-related and/or endoscopic factors associated with their occurrence. All data were collected prospectively. During 214 consecutive primary screening colonoscopies under conscious sedation(midazolam and pethidine), on top of pulse rate and SaO2,blood pressure and a three-channel ECG were recorded every five minutes. No major complications or relevant ECG changes occurred. Hypoxaemia occurred in 119 (55.6%),hypotension in 19 (8.9%) and bradycardia in 12 subjects(5.6%). In multivariate analysis, the sedation level 3 increased the risk of hypoxaemia (OR 4.8, CI 1.7-13.7), and incomplete colonoscopy (OR 5.3, CI 1.6-18.1) was associated with hypotension. Subjects with bradycardia had a longer mean procedure time (38±12 vs. 29±12 min, p<0.05), which did not turn out as a risk factor in a multivariate analysis. Mainly procedure-related and not subject-related factors were found to be associated with the occurrence of cardiopulmonary events in primary colonoscopy screening in this relatively healthy screening population.

  3. Risk of metachronous neoplasia on surveillance colonoscopy in young patients with colorectal neoplasia.

    PubMed

    Kim, Hyun Gun; Cho, Young-Seok; Cha, Jae Myung; Shin, Jeong Eun; Kim, Kyeong Ok; Yang, Hyo-Joon; Koo, Hoon Sup; Joo, Young-Eun; Boo, Sun-Jin

    2018-03-01

    Few prior reports exist that address the appropriate colonoscopy surveillance interval for individuals <50 years old. We compared the risk of metachronous neoplasia between younger (20-49 years) and older (50-54 years) cohorts. This multicenter retrospective cohort study compared the incidence of metachronous neoplasia in younger and older cohorts according to baseline risk stratification. Subjects were eligible if they underwent their first colonoscopy between June 2006 and May 2010 and had at least 1 or more surveillance colonoscopy up to June 2015. Among a total of 10,477 subjects who underwent baseline colonoscopy, 9722 were eligible after excluding 755 subjects. Of those 9722 subjects, 43% underwent surveillance colonoscopy. In the baseline high-risk adenoma group (n = 840), the 3-year risk of metachronous advanced neoplasia was 10.7% in the younger patients on screening colonoscopy and 8.9% in the older patients (P > .1). In the baseline low-risk adenoma group (n = 1869), the 5-year risk of metachronous advanced neoplasia was 4.9% in the younger patients on screening colonoscopy and 5.1% in the older patients (P > .1). Similarly, in the baseline no neoplasia group (n = 7013), the 5-year risk of metachronous advanced neoplasia was 4.1% in the younger patients on screening colonoscopy and 5.6% in the older patients (P > .1). Considering the similar risk of metachronous advanced neoplasia in younger and older individuals, we suggest a 3-year surveillance interval for high-risk adenoma and a 5-year surveillance interval for low-risk adenoma in young individuals without a strong family history. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  4. Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.

    PubMed

    Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G

    2017-07-01

    Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P <.001 for both). There was substantial agreement between endoscopist and referring provider impressions (κ=0.76). All 3 methods showed high sensitivity (>90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.

  5. Diverticular disease at colonoscopy in Lagos State, Nigeria.

    PubMed

    Oluyemi, Aderemi; Odeghe, Emuobor

    2016-01-01

    The upsurge in the reported cases of diverticular disease (DD) has led to a re-appraisal of the earlier held views that it was a rare entity in Nigeria. The advent of colonoscopy has contributed in no small way to this change. We sought to determine the clinical characteristics, indications for colonoscopy, and intra-procedural findings among these patients. A retrospective cross-sectional study was carried out on the colonoscopy records from four private endoscopy units based in Lagos State, Nigeria. The records were drawn from a 5-year period (August 2010 to July 2015). The endoscopy logs and reports were reviewed, and the bio data, indications, and colonoscopy findings were gleaned. A total of 265 colonoscopies were carried out in the stated period. Of these, 28 (10.6%) had DD. Of the patients with DD, 5 (17.9%) were females while 23 (82.1%) were males. Their ages ranged from 46 to 94 years (mean = 68.2 ± 11 years). Fifteen patients had been referred for the procedure on account of hematochezia alone (15 = 53.6%). Other reasons for referral included abdominal pain alone (2 = 7%), hematochezia plus abdominal pain (5 = 17.9%), and change in bowel habits (3 = 10.8%). Ten (35%) patients had pan-colonic involvement. Regional disease involved the right side alone in only one case (3.5%) while the other combinations of sites are as follows; 6 (21.4%) in the sigmoid colon alone, 2 (7%) in the descending colon alone, 5 (17.9%) in the sigmoid-descending colon, 4 (14.3%) in the sigmoid-descending-transverse colon, thus the sigmoid colon was involved in 25 (89.3%) cases. Five cases (17.9%) had endoscopic features suggestive of diverticulitis. DD should no longer be regarded as a rare problem in the Nigerian patient. The study findings support the notion of higher prevalence among the elderly, in males, and of sigmoid colon involvement.

  6. Serrated and adenomatous polyp detection increases with longer withdrawal time: results from the New Hampshire Colonoscopy Registry.

    PubMed

    Butterly, Lynn; Robinson, Christina M; Anderson, Joseph C; Weiss, Julia E; Goodrich, Martha; Onega, Tracy L; Amos, Christopher I; Beach, Michael L

    2014-03-01

    Detection and removal of adenomas and clinically significant serrated polyps (CSSPs) is critical to the effectiveness of colonoscopy in preventing colorectal cancer. Although longer withdrawal time has been found to increase polyp detection, this association and the use of withdrawal time as a quality indicator remains controversial. Few studies have reported on withdrawal time and serrated polyp detection. Using data from the New Hampshire Colonoscopy Registry, we examined how an endoscopist's withdrawal time in normal colonoscopies affects adenoma and serrated polyp detection. We analyzed 7,996 colonoscopies performed in 7,972 patients between 2009 and 2011 by 42 endoscopists at 14 hospitals, ambulatory surgery centers, and community practices. CSSPs were defined as sessile serrated polyps and hyperplastic polyps proximal to the sigmoid. Adenoma and CSSP detection rates were calculated based on median endoscopist withdrawal time in normal exams. Regression models were used to estimate the association of increased normal withdrawal time and polyp, adenoma, and CSSP detection. Polyp and adenoma detection rates were highest among endoscopists with 9 min median normal withdrawal time, and detection of CSSPs reached its highest levels at 8-9 min. Incident rate ratios for adenoma and CSSP detection increased with each minute of normal withdrawal time above 6 min, with maximum benefit at 9 min for adenomas (1.50, 95% confidence interval (CI) (1.21, 1.85)) and CSSPs (1.77, 95% CI (1.15, 2.72)). When modeling was used to set the minimum withdrawal time at 9 min, we predicted that adenomas and CSSPs would be detected in 302 (3.8%) and 191 (2.4%) more patients. The increase in detection was most striking for the CSSPs, with nearly a 30% relative increase. A withdrawal time of 9 min resulted in a statistically significant increase in adenoma and serrated polyp detection. Colonoscopy quality may improve with a median normal withdrawal time benchmark of 9 min.

  7. Progressive learning in endoscopy simulation training improves clinical performance: a blinded randomized trial.

    PubMed

    Grover, Samir C; Scaffidi, Michael A; Khan, Rishad; Garg, Ankit; Al-Mazroui, Ahmed; Alomani, Tareq; Yu, Jeffrey J; Plener, Ian S; Al-Awamy, Mohamed; Yong, Elaine L; Cino, Maria; Ravindran, Nikila C; Zasowski, Mark; Grantcharov, Teodor P; Walsh, Catharine M

    2017-11-01

    A structured comprehensive curriculum (SCC) that uses simulation-based training (SBT) can improve clinical colonoscopy performance. This curriculum may be enhanced through the application of progressive learning, a training strategy centered on incrementally challenging learners. We aimed to determine whether a progressive learning-based curriculum (PLC) would lead to superior clinical performance compared with an SCC. This was a single-blinded randomized controlled trial conducted at a single academic center. Thirty-seven novice endoscopists were recruited and randomized to either a PLC (n = 18) or to an SCC (n = 19). The PLC comprised 6 hours of SBT, which progressed in complexity and difficulty. The SCC included 6 hours of SBT, with cases of random order of difficulty. Both groups received expert feedback and 4 hours of didactic teaching. Participants were assessed at baseline, immediately after training, and 4 to 6 weeks after training. The primary outcome was participants' performance during their first 2 clinical colonoscopies, as assessed by using the Joint Advisory Group Direct Observation of Procedural Skills assessment tool (JAG DOPS). Secondary outcomes were differences in endoscopic knowledge, technical and communication skills, and global performance in the simulated setting. The PLC group outperformed the SCC group during first and second clinical colonoscopies, measured by JAG DOPS (P < .001). Additionally, the PLC group had superior technical and communication skills and global performance in the simulated setting (P < .05). There were no differences between groups in endoscopic knowledge (P > .05). Our findings demonstrate the superiority of a PLC for endoscopic simulation, compared with an SCC. Challenging trainees progressively is a simple, theory-based approach to simulation whereby the performance of clinical colonoscopies can be improved. (Clinical trial registration number: NCT02000180.). Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  8. [Chances and risks of prevention in elderly people for the three major cancers: breast-, prostate- and colorectal cancers].

    PubMed

    Kolb, G F

    2006-06-01

    The big three, breast cancer (BC), prostate cancer (PC) and colorectal carcinoma are the most frequent malignancies world wide and also typical tumors of advanced age. Therefore the question to screen and how to screen for these tumors in the elderly is the main question for reduction of the total cancer burden and mortality in all western countries. BREAST CANCER (BC): The age related risk of BC increases from 1 : 2,500 at age 30+ to > 1 : 10 at age 80. Nevertheless, most of the national BC-Screening-Programs stop at age 60 or earlier. Therefore the majority of all advanced i. e. T (4) stages of BC are found in women age > 60. Frequently it is suggested that age related comorbidity should eliminate the benefit of treatment. Recently two longitudinal studies have clearly shown that correct standard treatment is as effective in elderly as in younger individuals. Mammography (MG) has been shown to reduce mortality of BC significantly with best results for specificity and sensitivity at age 70+. PROSTATE CANCER (PC): The screening situation of PC is quite different to BC, because risk profiles are poorly defined and the benefit of radical prostatectomy is not clearly demonstrated in the early non symptomatic stages of PC. At the other side watchful waiting leads to an elevated frequency of incontinence and enuresis as well. Two studies are now under progress and may possibly change the situation; but the final results are expected 2005-2008 at the earliest. Therefore an assisted individual decision making is the only recommendation at this time. COLORECTAL CANCER (CC): Risk groups are clearly defined. Risk of the elderly (> 60) is the average risk. The incidence increases from < 50/10 (5) to more than 500 at age 75+(male) and 500 (female). When to start and when to stop screening? Experts give the advice to begin at age 50 and to end at age 80; but this is not really evidence based. There are several unanswered questions and open problems: we are not exactly informed about complication rates of colonoscopy during the screening programs. There is a lack of data according accuracy of barium enema, virtual colonoscopy and genetic stool test in comparison to colonoscopy in combination with fecal occult blood test (FOBT). And adherence to screening is not well documented among informed patients. However, effectiveness of CC-screening (FOBT alone or in combination with colonoscopy) has been documented in three high randomised trials which have shown a disease specific mortality reduction of 15-33 % over a period of 8-13 years. But it must be clear that the economic resources must be mobilised individually or by insurance: offering the testing of only FOBT for ten years to one thousand persons can save one life.

  9. Colonoscopy Screening in the US Astronaut Corps

    NASA Technical Reports Server (NTRS)

    Masterova, K.; Van Baalen, M.; Wear, M. L.; Murray, J.; Schaefer, C.

    2016-01-01

    Historically, colonoscopy screenings for astronauts have been conducted to ensure that astronauts are in good health for space missions. This data has been identified as being useful for determining appropriate occupational surveillance targets and requirements. Colonoscopies in the astronaut corps can be used for: (a) Assessing overall colon health, (b) A point of reference for future tests in current and former astronauts, (c) Following-up and tracking rates of colorectal cancer and polyps; and (d) Comparison to military and other terrestrial populations. In 2003, medical screening requirements for the active astronaut corps changed to require less frequent colonoscopies. Polyp removal during a colonoscopy is an intervention that prevents the polyp from potentially developing into cancer and decreases the individual's risk for colon cancer.

  10. A combined MR and CT study for precise quantitative analysis of the avian brain

    NASA Astrophysics Data System (ADS)

    Jirak, Daniel; Janacek, Jiri; Kear, Benjamin P.

    2015-10-01

    Brain size is widely used as a measure of behavioural complexity and sensory-locomotive capacity in avians but has largely relied upon laborious dissections, endoneurocranial tissue displacement, and physical measurement to derive comparative volumes. As an alternative, we present a new precise calculation method based upon coupled magnetic resonance (MR) imaging and computed tomography (CT). Our approach utilizes a novel interactive Fakir probe cross-referenced with an automated CT protocol to efficiently generate total volumes and surface areas of the brain tissue and endoneurocranial space, as well as the discrete cephalic compartments. We also complemented our procedures by using sodium polytungstate (SPT) as a contrast agent. This greatly enhanced CT applications but did not degrade MR quality and is therefore practical for virtual brain tissue reconstructions employing multiple imaging modalities. To demonstrate our technique, we visualized sex-based brain size differentiation in a sample set of Ring-necked pheasants (Phasianus colchicus). This revealed no significant variance in relative volume or surface areas of the primary brain regions. Rather, a trend towards isometric enlargement of the total brain and endoneurocranial space was evidenced in males versus females, thus advocating a non-differential sexually dimorphic pattern of brain size increase amongst these facultatively flying birds.

  11. Feasible economic strategies to improve screening compliance for colorectal cancer in Korea

    PubMed Central

    Park, Sang Min; Yun, Young Ho; Kwon, Soonman

    2005-01-01

    AIM: While colorectal cancer (CRC) is an ideal target for population screening, physician and patient attitudes contribute to low levels of screening uptake. This study was carried out to find feasible economic strategies to improve the CRC screening compliance in Korea. METHODS: The natural history of a simulated cohort of 50-year-old Korean in the general population was modeled with CRC screening until the age of 80 years. Cases of positive results were worked up with colonoscopy. After polypectomy, colonoscopy was repeated every 3 years. Baseline screening compliance without insurance coverage by the national health insurance (NHI) was assumed to be 30%. If NHI covered the CRC screening or the reimbursement of screening to physicians increased, the compliance was assumed to increase. We evaluated 16 different CRC screening strategies based on Markov model. RESULTS: When the NHI did not cover the screening and compliance was 30%, non-dominated strategies were colonoscopy every 5 years (COL5) and colonoscopy every 3 years (COL3). In all scenarios of various compliance rates with raised coverage of the NHI and increased reimbursement of colonoscopy, COL10, COL5 and COL3 were non-dominated strategies, and COL10 had lower or minimal incremental medical cost and financial burden on the NHI than the strategy of no screening. These results were stable with sensitivity analyses. CONCLUSION: Economic strategies for promoting screening compliance can be accompanied by expanding insurance coverage by the NHI and by increasing reimbursement for CRC screening to providers. COL10 was a cost-effective and cost saving screening strategy for CRC in Korea. PMID:15786532

  12. Variable stiffness colonoscopes are associated with less pain during colonoscopy in unsedated patients.

    PubMed

    Yoshikawa, Ichiro; Honda, Hidekazu; Nagata, Kaori; Kanda, Kikuo; Yamasaki, Takuji; Kume, Keiichiro; Tabaru, Akinari; Otsuki, Makoto

    2002-12-01

    Application of a new variable stiffness colonoscope (VSC) is expected to control loop formation and to lessen patient discomfort. The aim of this prospective study was to compare the efficacy of VSC with a conventional colonoscope (CC) in unsedated colonoscopy, based on the experience of examiners. Four-hundred sixty-seven patients were randomly assigned to undergo colonoscopy with either VSC or CC by an endoscopist, including experienced and less-experienced examiners. The percentages of completed procedure and time to cecal intubation were recorded. Patients were asked to rate pain on a 5-point pain score. The percentages of completed procedure with VSC and CC were 98% and 95%, respectively, by less-experienced hands, and 99% and 98%, respectively, by experienced hands. Time for cecal intubation with VSC and CC was 15.7 and 18.5 min, respectively, by less-experienced hands, and 9.8 and 10.6 min, respectively, by experienced hands. A significantly lower mean pain score was noted in VSC patients compared with CC patients, irrespective of experience of the examiner. The percent of patients rating the procedure as moderately or severely painful was significantly lower with VSC than with CC, both in less-experienced (19% vs 40%; p < 0.01) and experienced hands (15% vs 26%; p < 0.05). Our results indicated that VSC allows favorable examination compared with CC regarding completeness, time to cecal intubation, and comfort of patients undergoing unsedated colonoscopy, irrespective of the examiner's experience. These features suggest VSC as the preferred colonoscope for patients undergoing unsedated colonoscopy.

  13. Computer-aided detection of colorectal polyps: can it improve sensitivity of less-experienced readers? Preliminary findings.

    PubMed

    Baker, Mark E; Bogoni, Luca; Obuchowski, Nancy A; Dass, Chandra; Kendzierski, Renee M; Remer, Erick M; Einstein, David M; Cathier, Pascal; Jerebko, Anna; Lakare, Sarang; Blum, Andrew; Caroline, Dina F; Macari, Michael

    2007-10-01

    To determine whether computer-aided detection (CAD) applied to computed tomographic (CT) colonography can help improve sensitivity of polyp detection by less-experienced radiologist readers, with colonoscopy or consensus used as the reference standard. The release of the CT colonographic studies was approved by the individual institutional review boards of each institution. Institutions from the United States were HIPAA compliant. Written informed consent was waived at all institutions. The CT colonographic studies in 30 patients from six institutions were collected; 24 images depicted at least one confirmed polyp 6 mm or larger (39 total polyps) and six depicted no polyps. By using an investigational software package, seven less-experienced readers from two institutions evaluated the CT colonographic images and marked or scored polyps by using a five-point scale before and after CAD. The time needed to interpret the CT colonographic findings without CAD and then to re-evaluate them with CAD was recorded. For each reader, the McNemar test, adjusted for clustered data, was used to compare sensitivities for readers without and with CAD; a Wilcoxon signed-rank test was used to analyze the number of false-positive results per patient. The average sensitivity of the seven readers for polyp detection was significantly improved with CAD-from 0.810 to 0.908 (P=.0152). The number of false-positive results per patient without and with CAD increased from 0.70 to 0.96 (95% confidence interval for the increase: -0.39, 0.91). The mean total time for the readings was 17 minutes 54 seconds; for interpretation of CT colonographic findings alone, the mean time was 14 minutes 16 seconds; and for review of CAD findings, the mean time was 3 minutes 38 seconds. Results of this feasibility study suggest that CAD for CT colonography significantly improves per-polyp detection for less-experienced readers. Copyright (c) RSNA, 2007.

  14. Associations of Mental Health and Physical Function with Colonoscopy-related Pain

    PubMed Central

    Yamada, Eiji; Watanabe, Seitaro; Nakajima, Atsushi

    2017-01-01

    Objective To clarify the effects of mental health and physical function in association with colonoscopy-related pain. Methods The mental health and physical function were evaluated using the Japanese version of the SF-8 Health Survey questionnaire. Poor physical status was defined as a physical component summary (PCS) <40 and poor mental status as a mental component summary (MCS) <40. Pain was assessed using a visual analogue scale (VAS), with significant pain defined as VAS ≥70 mm and insignificant pain as VAS <70 mm. The background and colonoscopic findings were compared in patients with significant and insignificant pain. Patients This study evaluated consecutive Japanese patients who were positive on fecal occult blood tests and underwent total colonoscopy. Results Of the 100 patients, 23 had significant and 77 had insignificant colonoscopy-related pain. A multiple logistic regression analysis showed that MCS <40 [odds ratio (OR) 6.03; 95% confidence interval (CI) 1.41-25.9, p=0.0156], PCS <40 (OR 5.96; 95% CI 1.45-24.5, p=0.0133), and ≥300 seconds to reach the cecum (OR 4.13; 95% CI 1.16-14.7, p=0.0281) were independent risk factors for colonoscopy-related pain. Conclusion The mental health and physical function are important determinants of colonoscopy-related pain. Evaluating the mental health and physical function of patients prior to colonoscopy may effectively predict the degree of colonoscopy-related pain. PMID:28202858

  15. Do patients undergo prostate examination while having a colonoscopy?

    PubMed Central

    Hammett, Tess; Hookey, Lawrence C; Kawakami, Jun

    2009-01-01

    OBJECTIVES: To determine the rate at which physicians report performing a digital rectal examination and comment on the prostate gland before performing colonoscopy in men 50 to 70 years of age. METHODS: A retrospective chart review of all men 50 to 70 years of age who had a colonoscopy in Kingston, Ontario, in 2005 was completed. It was noted whether each physician described performing a digital rectal examination before the colonoscopy, and if so, whether he or she commented on the prostate. RESULTS: In 2005, 846 eligible colonoscopies were performed by 17 physicians in Kingston, Ontario. In 29.2% of cases, the physician made no comment about having performed a digital rectal examination; in 55.8% of cases, the physician commented on having completed a digital rectal examination but said nothing about the prostate; and in 15.0% of cases, the physician made a comment regarding the prostate. No physician consistently commented on the prostate for all patients, and in no circumstances was direct referral to another physician or follow-up suggested. DISCUSSION: A colonoscopy presents an ideal opportunity for physicians to use a digital rectal examination to assess for prostate cancer. Physicians performing colonoscopies in men 50 to 70 years of age should pay special attention to the prostate while performing a digital rectal examination before colonoscopy. This novel concept may help maximize resources for cancer screening and could potentially increase the detection rate of clinically palpable prostate cancer. PMID:19172207

  16. The Effectiveness of Short Message Service to Assure the Preparation-to-Colonoscopy Interval before Bowel Preparation for Colonoscopy

    PubMed Central

    Kim, Tae-Oh; Lee, Nae-Young; Kim, Hyoungjun; Seo, Eun Hee; Heo, Nae-Yun; Park, Seung Ha; Moon, Young-Soo

    2015-01-01

    Background/Aims. The preparation-to-colonoscopy (PC) interval is one of several important factors for the bowel preparation. Short message service (SMS) reminder from a cellular phone has been suggested to improve compliance in various medical situations. We evaluated the effectiveness of SMS reminders to assure the PC interval for colonoscopy. Methodology. This prospective randomized study was investigator blinded. In the No-SMS group, patients took the first 2 L polyethylene glycol (PEG) between 6 and 8 PM on the day before colonoscopy and the second 2 L PEG approximately 6 hours before the colonoscopy without SMS. In the SMS group, patients took first 2 L PEG in the same manner as the No-SMS group and the second 2 L PEG after receiving an SMS 6 hours before the colonoscopy. Results. The SMS group had a lower score than the No-SMS group, according to the Ottawa Bowel Preparation Scale (P < 0.001). Multivariate logistic regression analysis showed that compliance with diet instructions (odds ratio (OR) 2.109; 95% confidence interval (CI), 1.11–3.99, P = 0.022) and intervention using SMS ((OR) 2.329; 95% (CI), 1.34–4.02, P = 0.002) were the independent significant factors for satisfactory bowel preparation. Conclusions. An SMS reminder to assure PC interval improved the bowel preparation quality for colonoscopy with bowel preparation. PMID:25792978

  17. Colonoscopy Screening in the US Astronaut Corps

    NASA Technical Reports Server (NTRS)

    Masterova, K.; Van Baalen, M.; Wear, M. L.; Murray, J.; Schaefer, C.

    2016-01-01

    BACKGROUND: Historically, colonoscopy screenings for astronauts have been conducted to ensure that astronauts are in good health for space missions. Recently this historical data has been identified as being useful for developing an occupational surveillance requirement. It can be used to assess overall colon health and to have a point of reference for future tests in current and former astronauts, as well as to follow-up and track rates of colorectal cancer and polyps. These rates can be compared to military and other terrestrial populations. In 2003, the active astronaut colonoscopy requirements changed to require less frequent colonoscopies. Since polyp removal during a colonoscopy is an intervention that prevents the polyp from potentially developing into cancer, the procedure decreases the individual's risk for colon cancer. The objective of this study is to evaluate the possible effect of increased follow-up times between colonoscopies on the number and severity of polyps identified during the procedures among both current and former NASA astronauts. Initial results and forward work regarding astronaut colonoscopy screenings will be presented. METHODS: A retrospective study of all colonoscopy procedures performed on NASA astronauts between 1962 and 2015 (both during active career and retirement) was conducted by review of the JSC Clinic Electronic Medical Record and Lifetime Surveillance of Astronaut Health (LSAH) database for colonoscopy screening procedures and pathology reports. The timeframe of interest was from the time of selection into the Astronaut Corps through May 2015 or death. For each colonoscopy report, the following data were captured: date of procedure, age at time of procedure, reason for procedure, quality of bowel prep, completion of procedure and/or reason for termination of procedure, findings of procedure, subsequent treatment (if any), recommended follow-up interval, actual follow up interval, family history of polyps or colon cancer, and other significant items or discrepancies. The population consisted of 338 astronauts: 52 females, 286 males. Of these, 56 were deceased, and 11 astronauts had no record of any colonoscopies. Because of a screening requirement change in 2003, analyses were conducted to determine if there were differences between the two time periods. One-sided Wilcoxon rank sum tests were used to identify statistically significant differences between the two time periods. RESULTS: There was a combined total of 1,964 colonoscopy screenings identified. The average follow-up intervals between colonoscopies were indeed longer after the screening requirement change than before the change. The mean follow-up interval pre -2003 was 3.59 years, while post-2003 it increased to 4.35 years. The statistical significance of this difference was confirmed using a one sided Wilcoxon rank sum test which yielded p<.001. Colonoscopies performed after the requirement change tended to have a higher incidence and greater severity of polyps. From pre-2003 to post-2003 the percentage of colonoscopy procedures yielding no polyps decreased from 83.77% to 74.70%. Not only did post-2003 procedures yield more polyp findings, but the polyps recorded were more often of severe pathology. Before 2003 3.62% of colonoscopy findings were polyps of the hyperplastic type (the least severe polyp type) and only 3.35% were of greater severity. Post-2003, 4.21% of findings were hyperplastic polyps while 11.44% were of greater severity. Upon the investigation of other possible contributing factors to these results, we also found that mean age post-2003 was 54.55 years which was significantly higher than during the pre-2003 timeframe (47.32 years). This was observed with a one-sided Wilcoxon rank sum test, resulting in a p<0.001. The increased average age of astronauts could also be a contributing factor to the greater number of polyps found since the risk of developing polyps increases with age. Further work is needed to better understand the increased incidence and greater severity of polyps found in astronaut colonoscopy outcomes.

  18. Differences between genders in colorectal morphology on CT colonography using a quantitative approach: a pilot study.

    PubMed

    Weber, Charles N; Poff, Jason A; Lev-Toaff, Anna S; Levine, Marc S; Zafar, Hanna M

    To explore quantitative differences between genders in morphologic colonic metrics and determine metric reproducibility. Quantitative colonic metrics from 20 male and 20 female CTC datasets were evaluated twice by two readers; all exams were performed after incomplete optical colonoscopy. Intra-/inter-reader reliability was measured with intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). Women had overall decreased colonic volume, increased tortuosity and compactness and lower sigmoid apex height on CTC compared to men (p<0.0001,all). Quantitative measurements in colonic metrics were highly reproducible (ICC=0.9989 and 0.9970; CCC=0.9945). Quantitative morphologic differences between genders can be reproducibility measured. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Postpolypectomy Electrocoagulation Syndrome: A Mimicker of Colonic Perforation

    PubMed Central

    Benson, Brian C.; Myers, Jonathan J.; Laczek, Jeffrey T.

    2013-01-01

    Postpolypectomy electrocoagulation syndrome is a rare complication of polypectomy with electrocautery and is characterized by a transmural burn of the colon wall. Patients typically present within 12 hours after the procedure with symptoms mimicking colonic perforation. Presented is the case of a 56-year-old man who developed abdominal pain six hours after colonoscopy during which polypectomy was performed using snare cautery. CT imaging of the abdomen revealed circumferential thickening of the wall of the transverse colon without evidence of free air. The patient was treated conservatively as an outpatient and had resolution of his pain over the following four days. Recognition of the diagnosis and understanding of the treatment are important to avoid unnecessary exploratory laparotomy or hospitalization. PMID:23956889

  20. [A case of locally advanced sigmoid colon cancer curatively resected after neoadjuvant chemotherapy with FOLFIRI plus panitumumab].

    PubMed

    Horioka, Kohei; Kaku, Keizo; Jimi, Sei-ichirou; Oohata, Yoshihiro; Kamei, Takafumi

    2013-03-01

    A 72-year-old woman having abdominal pain and high fever was diagnosed with KRAS wild-type sigmoid colon cancer, invading the urinary bladder and uterus with a pelvic abscess. Considering the difficulty of curative resection, we first performed sigmoid colostomy and abscess drainage. Remarkable tumor regression was indicated by CT and colonoscopy after 1 course of FOLFIRI and 5 courses of FOLFIRI+panitumumab. Following an additional 2 courses of panitumumab, sigmoidectomy and partialcystectomy were performed. Six courses of FOLFIRI+panitumumab were administered postoperatively and no recurrence has been observed for 7 months. FOLFIRI+panitumumab may be an effective preoperative chemotherapy for patients with KRAS wild-type locally advanced colon cancer.

Top